WorldWideScience

Sample records for forced titration study

  1. Polymer-surfactant interactions studied by titration microcalorimetry : Influence of polymer hydrophobicity, electrostatic forces, and surfactant aggregational state

    NARCIS (Netherlands)

    Kevelam, J; van Breemen, J.F.L.; Blokzijl, W.; Engberts, J.B.F.N.

    1996-01-01

    Isothermal titration microcalorimetry has been applied to investigate the interactions between hydrophobically-modified water-soluble polymers and surfactants. The following polymers were used in this study: poly(sodium acrylate-co-n-alkyl methacrylate) (A), where n-alkyl = C9H19, C12H25, and C18H37

  2. [Titration comparative study of TOPINA Tablets in patients with localization related epilepsy: double-blind comparative study by rapid and slow titration methods].

    Science.gov (United States)

    Kaneko, Sunao; Inoue, Yushi; Sasagawa, Mutsuo; Kato, Masaaki

    2012-04-01

    To compare the tolerability and efficacy of two titration methods (rapid and slow titration) for TOPINA Tablets with different dosages and periods of escalation, a double-blind comparative study was conducted in patients with localization-related epilepsy. A total of 183 patients were randomized to either rapid titration (initial dosage 100 mg/day increased by 100-200 mg at weekly intervals) or to slow titration (initial dosage 50 mg/day increased in 50 mg/day increments at weekly intervals). TOPINA Tablets were administered for 12 weeks to the maximum dosage of 400 mg/day. The incident of adverse events leading to treatment interruptions or withdrawals was 18.9% in rapid titration and 14.8% in slow titration, with no statistical significance (p = 0.554). The incident of adverse events and adverse reactions of slow titration was slightly lower than that of rapid titration. The common adverse events and adverse reactions reported in the two titration methods were comparable and were well tolerated. On the other hand, the efficacy of slow titration, percent reduction in seizure rate and responder rate, was comparable with that of rapid titration. In conclusion, there were no significant differences of therapeutic response to TOPINA Tablets between the two titration methods.

  3. Interactions of benzoic acid and phosphates with iron oxide colloids using chemical force titration.

    Science.gov (United States)

    Liang, Jana; Horton, J Hugh

    2005-11-08

    Colloidal iron oxides are an important component in soil systems and in water treatment processes. Humic-based organic compounds, containing both phenol and benzoate functional groups, are often present in these systems and compete strongly with phosphate species for binding sites on the iron oxide surfaces. Here, we examine the interaction of benzoate and phenolic groups with various iron oxide colloids using atomic force microscopy (AFM) chemical force titration measurements. Self-assembled monolayers (SAMs) of 4-(12-mercaptododecyloxy)benzoic acid and 4-(12-mercaptododecyloxy)phenol were used to prepare chemically modified Au-coated AFM tips, and these were used to probe the surface chemistry of a series of iron oxide colloids. The SAMs formed were also characterized using scanning tunneling microscopy, reflection-absorption infrared spectroscopy, and X-ray photoelectron spectroscopy. The surface pK(a) of 4-(12- mercaptododecyloxy)benzoic acid has been determined to be 4.0 +/- 0.5, and the interaction between the tip and the sample coated with a SAM of this species is dominated by hydrogen bonding. The chemical force titraton profile for an AFM probe coated with 4-(12- mercaptododecyloxy)benzoic acid and a bare iron oxide colloid demonstrates that the benzoic acid function group interacts with all three types of iron oxide sites present on the colloid surface over a wide pH range. Similar experiments were carried out on colloids precipitated in the presence of phosphoric, gallic, and tannic acids. The results are discussed in the context of the competitive binding interactions of solution species present in soils or in water treatment processes.

  4. CHARITY: Chagas cardiomyopathy bisoprolol intervention study: a randomized double-blind placebo force-titration controlled study with Bisoprolol in patients with chronic heart failure secondary to Chagas cardiomyopathy [NCT00323973

    Directory of Open Access Journals (Sweden)

    Casas Juan P

    2006-06-01

    Full Text Available Abstract Background Chagas' disease is the major cause of disability secondary to tropical diseases in young adults from Latin America, and around 20 million people are currently infected by T. cruzi. Heart failure due to Chagas cardiomyopathy is the main clinical presenation in Colombia. Heart failure due to Chagas' disease may respond to digoxin, diuretics and vasodilator therapy. Beta-adrenoreceptor antagonism seems to protect against the increased risk of cardiac arrhythmia and sudden death due to chronic sympathetic stimulation. The aim of this study is to evaluate the effects of the selective beta-adrenergic receptor blocker Bisoprolol on cardiovascular mortality, hospital readmission due to progressive heart failure and functional status in patients with heart failure secondary to Chagas' cardiomyopathy. Methods/design A cohort of 500 T. cruzi seropositive patients (250 per arm will be selected from several institutions in Colombia. During the pretreatment period an initial evaluation visit will be scheduled in which participants will sign consent forms and baseline measurements and tests will be conducted including blood pressure measurements, twelve-lead ECG and left ventricular ejection fraction assessment by 2D echocardiography. Quality of life questionnaire will be performed two weeks apart during baseline examination using the "Minnesota living with heart failure" questionnaire. A minimum of two 6 minutes corridor walk test once a week over a two-week period will be performed to measure functional class. During the treatment period patients will be randomly assigned to receive Bisoprolol or placebo, initially taking a total daily dose of 2.5 mgrs qd. The dose will be increased every two weeks to 5, 7.5 and 10 mgrs qd (maximum maintenance dose. Follow-up assessment will include clinical check-up, and blood collection for future measurements of inflammatory reactants and markers. Quality of life measurements will be obtained at six

  5. Higher Order Inclusion Complexes and Secondary Interactions Studied by Global Analysis of Calorimetric Titrations

    DEFF Research Database (Denmark)

    Schönbeck, Jens Christian Sidney; Holm, René; Westh, Peter

    2012-01-01

    This paper investigates the use of isothermal titration calorimetry (ITC) as a tool for studying molecular systems in which weaker secondary interactions are present in addition to a dominant primary interaction. Such systems are challenging since the signal pertaining to the stronger primary......). The results are validated by a 13C NMR titration and negative controls with a bile salt with no secondary binding site (glycocholate) (K = 2.96 ± 0.01 × 103 M–1). The method proved useful for detailed analysis of ITC data and may strengthen its use as a tool for studying molecular systems by advanced binding...

  6. From contact angle titration to chemical force microscopy: a new route to assess the pH-dependent character of the stratum corneum.

    Science.gov (United States)

    Wagner, Matthieu; Mavon, Alain; Haidara, Hamidou; Vallat, Marie-France; Duplan, Hélène; Roucoules, Vincent

    2012-02-01

    Despite of its complex multicomponent organization and its compact architecture, the Stratum corneum (SC) is not completely impermeable to substances directly applied on the skin surface. A huge number of works have been dedicated to the understanding of the mechanisms involved in substance permeation by exploring deeper layers than the SC itself. Surprisingly, there is a poor interest in studies relating to interactions which may occur in the near-surface region (i.e. approximately 1 nm depth) of the SC. In this work, equilibrium proton-transfer reactions have been used as probes to define in a fundamental point of view the nature of the SC interactions with its environment. Such titration curves are investigated on 'in vitro' SC (isolated SC from abdominal skin tissue) and on 'in vivo' volar forearm (a sebum poor area). The results are discussed in term of work of adhesion and surface pKa values. Because SC can 'reconstruct' under heating, influence of the temperature on titration curves is investigated and the role of the different components is discussed. Different sigmoidal transitions were observed. Two common pKa values (pKa(1) = 4 and pKa(2) = 11.5) were clearly identified in both cases and associated to an acid-base character. By playing with the temperature of 'in vitro' SC, the 'accessibility' of polar functions was increased, thus refining the results by revealing an amphoteric character with an acid-to-base transition at pH 3.5 and two acid transitions at pH = 6.5 and pH = 11.5. Adhesion forces between an Atomic Force Microscopy (AFM) tip and a single isolated corneocyte through buffered liquid media were also investigated to better understand the role of the individual corneocytes. © 2011 The Authors. ICS © 2011 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  7. Interaction of chloroquine and its analogues with heme: An isothermal titration calorimetric study.

    Science.gov (United States)

    Bachhawat, K; Thomas, C J; Surolia, N; Surolia, A

    2000-10-05

    Quinoline-containing drugs such as chloroquine and quinine have had a long and successful history in antimalarial chemotherapy. Identification of ferriprotoporphyrin IX ([Fe(III)PPIX], haematin) as the drug receptors for these antimalarials called for investigations of the binding affinity, mode of interaction, and the conditions affecting the interaction. The parameters obtained are significant in recent times with the emergence of chloroquine resistant strains of the malaria parasites. This has underlined the need to unravel the molecular mechanism of their action so as to meet the requirement of an alternative to the existing antimalarial drugs. The isothermal titration calorimetric studies on the interaction of chloroquine with haematin lead us to propose an altered mode of binding. The initial recognition is ionic in nature mediated by the propionyl group of haematin with the quaternary nitrogen on CQ. This ionic interaction induces a conformational change, such as to favour binding of subsequent CQ molecules. On the contrary, conditions emulating the cytosolic environment (pH 7.4 and 150 mM salt) reveal the hydrophobic force to be the sole contributor driving the interaction. Interaction of a carefully selected panel of quinoline antimalarial drugs with monomeric ferriprotoporphyrin IX has also been investigated at pH 5.6 mimicking the acidic environment prevalent in the food vacuoles of parasite, the center of drug activity, which are consistent with their antimalarial activity. Copyright 2000 Academic Press.

  8. Thermodynamic investigations of protein's behaviour with ionic liquids in aqueous medium studied by isothermal titration calorimetry.

    Science.gov (United States)

    Bharmoria, Pankaj; Kumar, Arvind

    2016-05-01

    While a number of reports appear on ionic liquids-proteins interactions, their thermodynamic behaviour using suitable technique like isothermal titration calorimetry is not systematically presented. Isothermal titration calorimetry (ITC) is a key technique which can directly measure the thermodynamic contribution of IL binding to protein, particularly the enthalpy, heat capacities and binding stoichiometry. Ionic liquids (ILs), owing to their unique and tunable physicochemical properties have been the central area of scientific research besides graphene in the last decade, and growing unabated. Their encounter with proteins in the biological system is inevitable considering their environmental discharge though most of them are recyclable for a number of cycles. In this article we will cover the thermodynamics of proteins upon interaction with ILs as osmolyte and surfactant. The up to date literature survey of IL-protein interactions using isothermal titration calorimetry will be discussed and parallel comparison with the results obtained for such studies with other techniques will be highlighted to demonstrate the accuracy of ITC technique. Net stability of proteins can be obtained from the difference in the free energy (ΔG) of the native (folded) and denatured (unfolded) state using the Gibbs-Helmholtz equation (ΔG=ΔH-TΔS). Isothermal titration calorimetry can directly measure the heat changes upon IL-protein interactions. Calculation of other thermodynamic parameters such as entropy, binding constant and free energy depends upon the proper fitting of the binding isotherms using various fitting models. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. LIGHT TITRATIONS

    Science.gov (United States)

    Field, John; Baas-Becking, Lourens G. M.

    1926-01-01

    1. The usefulness of the radiomicrometer in titration work has been pointed out. The authors suggest that light titration may also be used where a reaction mixture changes its absorption in the (near) infra-red. 2. The applicability of this method to the starch-iodine reaction has been demonstrated. PMID:19872266

  10. Biocoordination chemistry. pH-metry titration method during study of biometal complexing with bioligands

    International Nuclear Information System (INIS)

    Dobrynina, N.A.

    1992-01-01

    Position of bioinorganic chemistry in the system of naturl science, as well as relations between bioinorganic and biocoordination chemistry, were considered. The content of chemical elements in geosphere and biosphere was analyzed. Characteristic features of biometal complexing with bioligands were pointed out. By way of example complex equilibria in solution were studie by the method of pH-metric titration using mathematical simulation. Advantages of the methods totality, when studying biosystems, were emphasized

  11. The SimpleMix study with biphasic insulin aspart 30: a randomized controlled trial investigating patient-driven titration versus investigator-driven titration.

    Science.gov (United States)

    Gao, Yan; Luquez, Cecilia; Lynggaard, Helle; Andersen, Henning; Saboo, Banshi

    2014-12-01

    The study aimed to confirm the efficacy, through non-inferiority, of patient-driven versus investigator-driven titration of biphasic insulin aspart 30 (BIAsp 30) in terms of glycemic control assessed by HbA1c change. SimpleMix was a 20 week, open-label, randomized, two-armed, parallel-group, multicenter study in five countries (Argentina, China, India, Poland, and the UK). Patients with type 2 diabetes were randomized into either patient-driven or investigator-driven BIAsp 30 titration groups. Non-inferiority of patient-driven vs. investigator-driven titration based on change in HbA1c from baseline to week 20 could not be demonstrated. Mean (SE) estimated change from baseline to week 20 was -0.72 (0.08)% in the patient-driven group and -0.97 (0.08)% in the investigator-driven group; estimated difference 0.25% (95% CI: 0.04; 0.46). Estimated mean change (SE) in fasting plasma glucose from baseline to week 20 was similar between groups: -0.94 (0.21) mmol/L for patient-driven and -1.07 (0.22) mmol/L for investigator-driven (difference non-significant). Both treatment arms were well tolerated, and hypoglycemic episode rates were similar between groups, with a rate ratio of 0.77 (95% CI: 0.54; 1.09; p = 0.143) for all hypoglycemic episodes and 0.78 (95% CI: 0.42; 1.43; p = 0.417) for nocturnal hypoglycemic episodes. Non-inferiority of patient-driven versus investigator-driven titration with regard to change from baseline to end-of-treatment HbA1c could not be confirmed. It is possible that a clinic visit 12 weeks after intensification of treatment with BIAsp 30 in patients with type 2 diabetes inadequately treated with basal insulin may benefit patient-driven titration of BIAsp 30. A limitation of the study was the relatively small number of patients recruited in each country, which does not allow country-specific analyses to be performed. Overall, treatment with BIAsp 30 was well tolerated in both treatment groups.

  12. Study of complex amalgams containing alkali metals by method of broken thermometric titration

    International Nuclear Information System (INIS)

    Filippova, L.M.; Zebreva, A.I.; Espenbetov, A.A.

    1977-01-01

    Complex potassium-cadmium and sodium-cadmium amalgams containing different amounts of the alkali metal nad cadmium have been studied by thermometric titration with mercury. The experiments have been carried out in argon atmosphere at 25 deg C. As evidenced by the titration of sodium-cadmium amalgams, in the range of concentrations studied (Csub(Na)=0.71-2.95, Csub(Cd)=4.38-6.45 g-at/lHg) no solid phase is formed in them. Potassium-cadmium amalgams where the metals content is no higher than their individual solubility in mercury, display, when being mercury-titrated, negative heat effects due to solid phase formation. An estimation is made of the solid phase composition, its solubility in mercury and the heat of dissolution. The solid phase appearing in complex K-Cd amalgams is likely to contain K and Cd in a ratio 1:1 its conventional solubility product is 5.4 g-at/l Hg, and the heat of dissolution in mercury at 25 deg is -21 +-4 kJ/g-at

  13. Concentration-related response potentiometric titrations to study the interaction of small molecules with large biomolecules.

    Science.gov (United States)

    Hamidi-Asl, Ezat; Daems, Devin; De Wael, Karolien; Van Camp, Guy; Nagels, Luc J

    2014-12-16

    In the present paper, the utility of a special potentiometric titration approach for recognition and calculation of biomolecule/small-molecule interactions is reported. This approach is fast, sensitive, reproducible, and inexpensive in comparison to the other methods for the determination of the association constant values (Ka) and the interaction energies (ΔG). The potentiometric titration measurement is based on the use of a classical polymeric membrane indicator electrode in a solution of the small-molecule ligand. The biomolecule is used as a titrant. The potential is measured versus a reference electrode and transformed into a concentration-related signal over the entire concentration interval, also at low concentrations, where the millivolt (y-axis) versus log canalyte (x-axis) potentiometric calibration curve is not linear. In the procedure, Ka is calculated for the interaction of cocaine with a cocaine binding aptamer and with an anticocaine antibody. To study the selectivity and cross-reactivity, other oligonucleotides and aptamers are tested, as well as other small ligand molecules such as tetrakis(4-chlorophenyl)borate, metergoline, lidocaine, and bromhexine. The calculated Ka compared favorably to the value reported in the literature using surface plasmon resonance. The potentiometric titration approach called "concentration-related response potentiometry" is used to study molecular interaction for seven macromolecular target molecules and four small-molecule ligands.

  14. Potentiometric and spectrophotometric titration study of interaction of tungstovanadophosphoric heteropolyacids with sodium hydroxide

    International Nuclear Information System (INIS)

    Borkoyakov, S.A.; Fisun, L.A.

    1988-01-01

    The methods of potentiometric and spectrophotometric titration are used to study H s+n PW 12-n V n O 40 (n=1,2) (P-W-V HPA) decomposition by sodium hydroxide. It is shown that at the first stage of heteropolyanion interaction with alkali (pH) > 4 P-W-V HPA structural reconstruction takes place. It is accompanied by the formation of complexes with a higher content of vanadium atoms stable at pH 4-7/ P-W-V HPA decomposition to initial salts occurs at pH > 8

  15. Titration calorimetry of surfactant–drug interactions: Micelle formation and saturation studies

    International Nuclear Information System (INIS)

    Waters, Laura J.; Hussain, Talib; Parkes, Gareth M.B.

    2012-01-01

    Highlights: ► Isothermal titration calorimetry can be used to monitor the saturation of micelles with pharmaceutical compounds. ► The number of drug molecules per micelle varies depending on the drug used and the temperature of the calorimeter. ► The change in enthalpy for the saturation of micelles with drugs can be endothermic or exothermic. ► The critical micellar concentration of an anionic surfactant (SDS) does not appear to vary in the presence of drugs. - Abstract: Isothermal titration calorimetry (ITC) was employed to monitor the addition of five model drugs to anionic surfactant based micelles, composed of sodium dodecyl sulfate (SDS), through to the point at which they were saturated with drug. Analysis of the resultant data using this newly developed method has confirmed the suitability of the technique to acquire such data with saturation limits established in all cases. Values for the point at which saturation occurred ranged from 17 molecules of theophylline per micelle at T = 298 K up to 63 molecules of caffeine per micelle at 310 K. Micellar systems can be disrupted by the presence of additional chemicals, such as the drugs used in this study, therefore a separate investigation was undertaken to determine the critical micellar concentration (CMC) for SDS in the presence of each drug at T = 298 K and 310 K using ITC. In the majority of cases, there was no appreciable alteration to the CMC of SDS with drug present.

  16. Integration and global analysis of isothermal titration calorimetry data for studying macromolecular interactions.

    Science.gov (United States)

    Brautigam, Chad A; Zhao, Huaying; Vargas, Carolyn; Keller, Sandro; Schuck, Peter

    2016-05-01

    Isothermal titration calorimetry (ITC) is a powerful and widely used method to measure the energetics of macromolecular interactions by recording a thermogram of differential heating power during a titration. However, traditional ITC analysis is limited by stochastic thermogram noise and by the limited information content of a single titration experiment. Here we present a protocol for bias-free thermogram integration based on automated shape analysis of the injection peaks, followed by combination of isotherms from different calorimetric titration experiments into a global analysis, statistical analysis of binding parameters and graphical presentation of the results. This is performed using the integrated public-domain software packages NITPIC, SEDPHAT and GUSSI. The recently developed low-noise thermogram integration approach and global analysis allow for more precise parameter estimates and more reliable quantification of multisite and multicomponent cooperative and competitive interactions. Titration experiments typically take 1-2.5 h each, and global analysis usually takes 10-20 min.

  17. Ln(III)-malate complexation studies using TRLFS and micro titration calorimetry

    International Nuclear Information System (INIS)

    Taube, F.; Drobot, B.; Acker, M.; Taut, S.; Stumpf, Thorsten

    2017-01-01

    The complexation of trivalent lanthanides was studied using Time-Resolved Laser-Induced Fluorescence Spectroscopy (TRLFS) and Isothermal Titration Calorimetry (ITC). Formation constants, complexation enthalpies and fluorescence lifetimes are determined over a wide pH range at I = 0.5 m NaCl. This subject has the following background: Concrete is widely used as engineering barrier and for waste conditioning in waste repositories. Its binding agent is cement. Organic cement additives, which are used to improve the workability of fresh concrete, are complexation agents for radionuclides after they have been released during the concretes degradation. Thus, these additives might have an impact on the aqueous geochemistry of actinides. Here, the α-hydroxydicarboxylic acid or malic acid is examined. It is used in water-reducers or retarders in cement.

  18. Ln(III)-malate complexation studies using TRLFS and micro titration calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Taube, F.; Drobot, B. [Technische Univ. Dresden (Germany). Professorship Radiochemistry; Acker, M.; Taut, S. [Technische Univ. Dresden (Germany). Central Radionuclide Laboratory; Stumpf, Thorsten [Helmholtz-Zentrum Dresden-Rossendorf e.V., Dresden (Germany). Inst. of Resource Ecology

    2017-06-01

    The complexation of trivalent lanthanides was studied using Time-Resolved Laser-Induced Fluorescence Spectroscopy (TRLFS) and Isothermal Titration Calorimetry (ITC). Formation constants, complexation enthalpies and fluorescence lifetimes are determined over a wide pH range at I = 0.5 m NaCl. This subject has the following background: Concrete is widely used as engineering barrier and for waste conditioning in waste repositories. Its binding agent is cement. Organic cement additives, which are used to improve the workability of fresh concrete, are complexation agents for radionuclides after they have been released during the concretes degradation. Thus, these additives might have an impact on the aqueous geochemistry of actinides. Here, the α-hydroxydicarboxylic acid or malic acid is examined. It is used in water-reducers or retarders in cement.

  19. Study on the use of solid electrodes for potentiometric titrations in non-aqueous solvents-I

    International Nuclear Information System (INIS)

    Fatibello Filho, O.; Carvalho, W.M. de; Capelato, M.D.; Bulhoes, L.O.S.; Almeida Neves, E.F. de

    1984-01-01

    Fatty acids and ethanolamines were titrated potentiometrically with tetrabutylammnonium hydroxide in methyl isobutyl ketone-isopropyl alcohol and with perchloric acid in ethanol, respectively. A study of utilization of Sb, Sn, W, PbO 2 , Ti and 316L stainless steel oxides - Ag/AgBr/Bu 4 NBr (x M)/solvent electrode systems have been investigated in comparison with the glass - Ag/AgBr/Bu 4 NBr (x M)/solvent system. The best performance was obtained using W, Sb, PbO 2 and Ti electrodes have yielded a larger potential shift than glass electrode for acid-base titration. (C.L.B.) [pt

  20. Isothermal Titration Calorimetry and Fluorescence Spectroscopy Study Of Asphaltene Self-Association In Toluene And Interaction With A Model Resin

    DEFF Research Database (Denmark)

    Garcia, Daniel Merino; Andersen, Simon Ivar

    2002-01-01

    This article collects the work performed by Isothermal Titration Caloritnetry (ITC) in the study of the self-association of asphaltenes in toluene solutions. Calorimetric experiments show that asphaltenes, start self-associating at very low concentrations and that the existence of a Critical...... with the results of the titration of three model molecules: nonylphenol, which associates by means of hydrogen bond formation, and coronene and pyrene, which associates by stacking. The results obtained leave open the question about the model-stacking molecules, as it was not possible to elucidate whether they do...

  1. Origin of two time-scale regimes in potentiometric titration of metal oxides. A replica kinetic Monte Carlo study

    International Nuclear Information System (INIS)

    Zarzycki, Piotr P.; Rosso, Kevin M.

    2009-01-01

    Replica Kinetic Monte Carlo simulations were used to study the characteristic time scales of potentiometric titration of the metal oxides and (oxy)hydroxides. The effect of surface heterogeneity and surface transformation on the titration kinetics were also examined. Two characteristic relaxation times are often observed experimentally, with the trailing slower part attributed to surface non-uniformity, porosity, polymerization, amorphization, and other dynamic surface processes induced by unbalanced surface charge. However, our simulations show that these two characteristic relaxation times are intrinsic to the proton binding reaction for energetically homogeneous surfaces, and therefore surface heterogeneity or transformation do not necessarily need to be invoked. However, all such second-order surface processes are found to intensify the separation and distinction of the two kinetic regimes. The effect of surface energetic-topographic non-uniformity, as well dynamic surface transformation, interface roughening/smoothing were described in a statistical fashion. Furthermore, our simulations show that a shift in the point-of-zero charge is expected from increased titration speed and the pH-dependence of the titration measurement error is in excellent agreement with experimental studies.

  2. Origin of two time-scale regimes in potentiometric titration of metal oxides. A replica kinetic Monte Carlo study.

    Science.gov (United States)

    Zarzycki, Piotr; Rosso, Kevin M

    2009-06-16

    Replica kinetic Monte Carlo simulations were used to study the characteristic time scales of potentiometric titration of the metal oxides and (oxy)hydroxides. The effect of surface heterogeneity and surface transformation on the titration kinetics were also examined. Two characteristic relaxation times are often observed experimentally, with the trailing slower part attributed to surface nonuniformity, porosity, polymerization, amorphization, and other dynamic surface processes induced by unbalanced surface charge. However, our simulations show that these two characteristic relaxation times are intrinsic to the proton-binding reaction for energetically homogeneous surfaces, and therefore surface heterogeneity or transformation does not necessarily need to be invoked. However, all such second-order surface processes are found to intensify the separation and distinction of the two kinetic regimes. The effect of surface energetic-topographic nonuniformity, as well dynamic surface transformation, interface roughening/smoothing were described in a statistical fashion. Furthermore, our simulations show that a shift in the point-of-zero charge is expected from increased titration speed, and the pH-dependence of the titration measurement error is in excellent agreement with experimental studies.

  3. Characteristics and thermodynamics of the interaction of 6-shogaol with human serum albumin as studied by isothermal titration calorimetry

    Directory of Open Access Journals (Sweden)

    Shevin Rizal Feroz

    Full Text Available ABSTRACT The interaction between 6-shogaol, a pharmacologically active ginger constituent, and human serum albumin (HSA, the main in vivo drug transporter, was investigated using isothermal titration calorimetry (ITC. The value of the binding constant, Ka (5.02 ± 1.37 × 104 M−1 obtained for the 6-shogaol-HSA system suggested intermediate affinity. Analysis of the ITC data revealed feasibility of the binding reaction due to favorable enthalpy and entropy changes. The values of the thermodynamic parameters suggested involvement of van der Waals forces, hydrogen bonds and hydrophobic interactions in the 6-shogaol-HSA complex formation.

  4. Model compounds of humic acid and oxovanadium cations. Potentiometric titration and EPR spectroscopy studies

    Directory of Open Access Journals (Sweden)

    Mercê Ana Lucia Ramalho

    1999-01-01

    Full Text Available The stability constants and the isotropic EPR parameters Ao (hyperfine splitting constant and g o (g value were obtained by potentiometric titrations and EPR spectroscopy, respectively, of 85%v/v aqueous solutions of model compounds of humic acids - salicylic acid (SALA - and both nitrohumic acids, a laboratory artifact - nitrosalicylic acids, 3-nitrosalicylic acid (3-NSA, 5-nitrosalicylic acid (5-NSA and 3,5-dinitrosalicylic acid (3,5-DNSA and oxovanadium cations. It was possible to record EPR spectra of those model compounds and the ion VO2+ (V(IV, and the stability constants were obtained from a solution of VO3+ (V(V, the values for the logarithms of the stability constants ranging from 12.77 ± 0.04 to 7.06 ± 0.05 for the species ML, and from 9.90 ±0.04 to 4.06 ± 0.05 for the species ML2 according to the decrease in the acidity of the carboxylic and the hydroxyl groups in the aromatic ring of the model compounds studied as the -NO2 substituents were added. Species distribution diagrams were also obtained for the equilibria studied. The EPR parameters showed that as the logarithm of the overall stability constants increase, g o values also increase, while Ao values show a tendency to decrease.

  5. Pilot study of a new device to titrate oxygen flow in hypoxic patients on long-term oxygen therapy.

    Science.gov (United States)

    Cirio, Serena; Nava, Stefano

    2011-04-01

    The O(2) Flow Regulator (Dima, Bologna, Italy) is a new automated oxygen regulator that titrates the oxygen flow based on a pulse-oximetry signal to maintain a target S(pO(2)). We tested the device's safety and efficacy. We enrolled 18 subjects with chronic lung disease, exercise-induced desaturation, and on long-term oxygen therapy, in a randomized crossover study with 2 constant-work-load 15-min cycling exercise tests, starting with the patient's previously prescribed usual oxygen flow. In one test the oxygen flow was titrated manually by the respiratory therapist, and in the other test the oxygen flow was titrated by the O(2) Flow Regulator, to maintain an S(pO(2)) of 94%. We measured S(pO(2)) throughout each test, the time spent by the respiratory therapist to set the device or to manually regulate the oxygen flow, and the total number of respiratory-therapist titration interventions during the trial. There were no differences in symptoms or heart rate between the exercise tests. Compared to the respiratory-therapist-controlled tests, during the O(2) Flow Regulator tests S(pO(2)) was significantly higher (95 ± 2% vs 93 ± 3%, P = .04), significantly less time was spent below the target S(pO(2)) (171 ± 187 s vs 340 ± 220 s, P less respiratory therapist time (5.6 ± 3.7 min vs 2.0 ± 0.1 min, P = .005). The O(2) Flow Regulator may be a safe and effective alternative to manual oxygen titration during exercise in hypoxic patients. It provided stable S(pO(2)) and avoided desaturations in our subjects.

  6. Micellization of bovine beta-casein studied by isothermal titration microcalorimetry and cryogenic transmission electron microscopy.

    Science.gov (United States)

    Portnaya, Irina; Cogan, Uri; Livney, Yoav D; Ramon, Ory; Shimoni, Karin; Rosenberg, Moshe; Danino, Dganit

    2006-07-26

    The association behavior, critical micellization concentration (CMC), and enthalpy of demicellization (DeltaHdemic) of bovine beta-casein were studied, for the first time by isothermal titration calorimetry, in a pH 7.0 phosphate buffer with 0.1 ionic strength and in pure water. In the buffer solutions, the CMC decreased asymptotically from 0.15 to 0.006 mM as the temperature was raised from 16 to 45 degrees C. DeltaHdemic decreased with increasing temperature between 16 and 28 degrees C but increased from 28 to 45 degrees C. Thermodynamic analysis below 30 degrees C is consistent with the Kegeles shell model, which suggests a stepwise association process. At higher temperatures, this model exhibits limitations, and the micellization becomes much more cooperative. The CMC values in water, measured between 17 and 28 degrees C, decreased with increasing temperature and, expectedly, were higher than those found in the buffer solutions. beta-Casein micelles were visualized and characterized, for the first time in their hydrated state, using advanced digital-imaging cryogenic transmission electron microscopy. The images revealed small, oblate micelles, about approximately 13 nm in diameter. The micelles shape and dimensions remained nearly constant in the temperature range of 24-35 degrees C.

  7. Dose Titration of Pregabalin in Patients with Painful Diabetic Peripheral Neuropathy: Simulation Based on Observational Study Patients Enriched with Data from Randomized Studies.

    Science.gov (United States)

    Alexander, Joe; Edwards, Roger A; Manca, Luigi; Grugni, Roberto; Bonfanti, Gianluca; Emir, Birol; Whalen, Edward; Watt, Stephen; Parsons, Bruce

    2018-03-01

    Achieving a therapeutic response to pregabalin in patients with painful diabetic peripheral neuropathy (pDPN) requires adequate upward dose titration. Our goal was to identify relationships between titration and response to pregabalin in patients with pDPN. Data were integrated from nine randomized, placebo-controlled clinical trials as well as one 6-week open-label observational study conducted by 5808 physicians (2642 patients with pDPN) in standard outpatient settings in Germany. These studies evaluated pregabalin for treatment of pDPN. Using these data, we examined "what if" scenarios using a microsimulation platform that integrates data from randomized and observational sources as well as autoregressive-moving-average with exogenous inputs models that predict pain outcomes, taking into account weekly changes in pain, sleep interference, dose, and other patient characteristics that were unchanging. Final pain levels were significantly different depending on dose changes (P titration regardless of baseline pain severity. Altogether, 78.5% of patients with pDPN had 0-1 dose change, and 15.2% had ≥ 2 dose changes. Simulation demonstrated that the 4.8% of inadequately titrated patients who did not improve/very much improve their pain levels would have benefited from ≥ 2 dose changes. Patient satisfaction with tolerability (range 90.3-96.2%) was similar, regardless of baseline pain severity, number of titrations, or extent of improvement, suggesting that tolerability did not influence treatment response patterns. Upward dose titration reduced pain in patients with pDPN who actually received it. Simulation also predicted pain reduction in an inadequately titrated nonresponder subgroup of patients had they actually received adequate titration. The decision not to uptitrate must have been driven by factors other than tolerability. Pfizer, Inc.

  8. The Davies-Gray titration for the assay of uranium in nuclear materials: a performance study

    International Nuclear Information System (INIS)

    Bickel, M.

    1997-01-01

    An interlaboratory comparison in two phases was organized to assess the precision and accuracy concerning the assay of uranium in nuclear materials by the potentiometric titration method. This contribution presents the results of this exercise in terms of method performance. Variations to be expected between different laboratories and within a single laboratory are estimated. In general, the method proved again very reliable. (orig.)

  9. Repeated dose titration versus age-based method in electroconvulsive therapy: a pilot study

    NARCIS (Netherlands)

    Aten, J.J.; Oudega, M.L.; van Exel, E.; Stek, M.L.; van Waarde, J.A.

    2015-01-01

    In electroconvulsive therapy (ECT), a dose titration method (DTM) was suggested to be more individualized and therefore more accurate than formula-based dosing methods. A repeated DTM (every sixth session and dose adjustment accordingly) was compared to an age-based method (ABM) regarding treatment

  10. Hydrolysis-precipitation studies of aluminum (III) solutions. I. Titration of acidified aluminum nitrate solutions

    NARCIS (Netherlands)

    Vermeulen, A.C.; Geus, John W.; Stol, R.J.; Bruyn, P.L. de

    Acidified aluminum nitrate solutions were titrated with alkali (NaOH or KOH) over a temperature range of 24°C to 90°C. A homogeneous distribution of added base was achieved by: (i) in situ decomposition of urea (90°C); and (ii) a novel method involving injection through a capillary submerged in the

  11. Binding of Cu(II) ions to peptides studied by fluorescence spectroscopy and isothermal titration calorimetry

    Science.gov (United States)

    Makowska, Joanna; Żamojć, Krzysztof; Wyrzykowski, Dariusz; Uber, Dorota; Wierzbicka, Małgorzata; Wiczk, Wiesław; Chmurzyński, Lech

    2016-01-01

    Steady-state and time-resolved fluorescence quenching measurements supported by Isothermal Titration Calorimetry (ITC) were used to study the interactions of Cu2 + with four peptides. Two of them were taken from the N-terminal part of the FBP28 protein (formin binding protein) WW domain: Tyr-Lys-Thr-Ala-Asp-Gly-Lys-Thr-Tyr-NH2 (D9) and its mutant Tyr-Lys-Thr-Ala-Asn-Gly-Lys-Thr-Tyr-NH2 (D9_M) as well as two mutated peptides from the B3 domain of the immunoglobulin binding protein G derived from Streptococcus: Asp-Val-Ala-Thr-Tyr-Thr-NH2 (J1) and Glu-Val-Ala-Thr-Tyr-Thr-NH2 (J2). The measurements were carried out at 298.15 K in 20 mM 2-(N-morpholino)ethanesulfonic acid (MES) buffer solution with a pH of 6. The fluorescence of all peptides was quenched by Cu2 + ions. The stoichiometry, conditional stability constants and thermodynamic parameters for the interactions of the Cu2 + ions with D9 and D9_M were determined from the calorimetric data. The values of the conditional stability constants were additionally determined from fluorescence quenching measurements and compared with those obtained from calorimetric studies. There was a good correlation between data obtained from the two techniques. On the other hand, the studies revealed that J1 and J2 do not exhibit an affinity towards metal ions. The obtained results prove that fluorescence quenching experiments may be successfully used in order to determine stability constants of complexes with fluorescent ligands. Finally, based on the obtained results, the coordinating properties of the peptides towards the Cu2 + ions are discussed.

  12. Binding of Cu(II) ions to peptides studied by fluorescence spectroscopy and isothermal titration calorimetry.

    Science.gov (United States)

    Makowska, Joanna; Żamojć, Krzysztof; Wyrzykowski, Dariusz; Uber, Dorota; Wierzbicka, Małgorzata; Wiczk, Wiesław; Chmurzyński, Lech

    2016-01-15

    Steady-state and time-resolved fluorescence quenching measurements supported by Isothermal Titration Calorimetry (ITC) were used to study the interactions of Cu(2+) with four peptides. Two of them were taken from the N-terminal part of the FBP28 protein (formin binding protein) WW domain: Tyr-Lys-Thr-Ala-Asp-Gly-Lys-Thr-Tyr-NH2 (D9) and its mutant Tyr-Lys-Thr-Ala-Asn-Gly-Lys-Thr-Tyr-NH2 (D9_M) as well as two mutated peptides from the B3 domain of the immunoglobulin binding protein G derived from Streptococcus: Asp-Val-Ala-Thr-Tyr-Thr-NH2 (J1) and Glu-Val-Ala-Thr-Tyr-Thr-NH2 (J2). The measurements were carried out at 298.15K in 20mM 2-(N-morpholino)ethanesulfonic acid (MES) buffer solution with a pH of 6. The fluorescence of all peptides was quenched by Cu(2+) ions. The stoichiometry, conditional stability constants and thermodynamic parameters for the interactions of the Cu(2+) ions with D9 and D9_M were determined from the calorimetric data. The values of the conditional stability constants were additionally determined from fluorescence quenching measurements and compared with those obtained from calorimetric studies. There was a good correlation between data obtained from the two techniques. On the other hand, the studies revealed that J1 and J2 do not exhibit an affinity towards metal ions. The obtained results prove that fluorescence quenching experiments may be successfully used in order to determine stability constants of complexes with fluorescent ligands. Finally, based on the obtained results, the coordinating properties of the peptides towards the Cu(2+) ions are discussed. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Repeated dose titration versus age-based method in electroconvulsive therapy: a pilot study.

    Science.gov (United States)

    Aten, Jan Jaap; Oudega, Mardien; van Exel, Eric; Stek, Max L; van Waarde, Jeroen A

    2015-06-01

    In electroconvulsive therapy (ECT), a dose titration method (DTM) was suggested to be more individualized and therefore more accurate than formula-based dosing methods. A repeated DTM (every sixth session and dose adjustment accordingly) was compared to an age-based method (ABM) regarding treatment characteristics, clinical outcome, and cognitive functioning after ECT. Thirty-nine unipolar depressed patients dosed using repeated DTM and 40 matched patients treated with ABM were compared. Montgomery-Åsberg Depression Rating Scale (MADRS) and Mini-Mental State Examination (MMSE) were assessed at baseline and at the end of the index course, as well as the total number of ECT sessions. Both groups were similar regarding age, sex, psychotic features, mean baseline MADRS, and median baseline MMSE. At the end of the index course, the two methods showed equal outcome (mean end MADRS, 11.6 ± 8.3 in DTM and 9.5 ± 7.6 in ABM (P = 0.26); median end MMSE, 28 (25-29) and 28 (25-29.8), respectively (P = 0.81). However, the median number of all ECT sessions differed 16 (11-22) in DTM versus 12 (10-14.8) in ABM; P = 0.02]. Using regression analysis, dosing method and age were independently associated with the total number of ECT sessions, with less sessions needed in ABM (P = 0.02) and in older patients (P = 0.001). In this comparative cohort study, ABM and DTM showed equal outcome for depression and cognition. However, the median ECT course duration in repeated DTM appeared longer. Additionally, higher age was associated with shorter ECT courses regardless of the dosing method. Further prospective studies are needed to confirm these findings.

  14. Thermometric titration of sulphate.

    Science.gov (United States)

    Williams, M B; Janata, J

    1970-06-01

    Direct thermometric titration of sulphate with a solution of barium perchlorate is proposed. The stoichiometry of the titration is shown to be critically dependent on the concentration of ethanol in the titration medium. The titration is rapid and suffers from only a few interferences.

  15. The binding of aluminum to mugineic acid and related compounds as studied by potentiometric titration.

    Science.gov (United States)

    Yoshimura, Etsuro; Kohdr, Hicham; Mori, Satoshi; Hider, Robert C

    2011-08-01

    The phytosiderophores, mugineic acid (MA) and epi-hydroxymugineic acid (HMA), together with a related compound, nicotianamine (NA), were investigated for their ability to bind Al(III). Potentiometric titration analysis demonstrated that MA and HMA bind Al(III), in contrast to NA which does not under normal physiological conditions. With MA and HMA, in addition to the Al complex (AlL), the protonated (AlLH) and deprotonated (AlLH(-1)) complexes were identified from an analysis of titration curves, where L denotes the phytosiderophore form in which all the carboxylate functions are ionized. The equilibrium formation constants of the Al(III) phytosiderophore complexes are much smaller than those of the corresponding Fe(III) complexes. The higher selectivity of phytosiderophores for Fe(III) over Al(III) facilitates Fe(III) acquisition in alkaline conditions where free Al(III) levels are higher than free Fe(III) levels.

  16. Spectroscopic study on variations in illite surface properties after acid-base titration.

    Science.gov (United States)

    Liu, Wen-xin; Coveney, R M; Tang, Hong-xiao

    2003-07-01

    FT-IR, Raman microscopy, XRD, 29Si and 27Al MAS NMR, were used to investigate changes in surface properties of a natural illite sample after acid-base potentiometric titration. The characteristic XRD lines indicated the presence of surface Al-Si complexes, preferable to Al(OH)3 precipitates. In the microscopic Raman spectra, the vibration peaks of Si-O and Al-O bonds diminished as a result of treatment with acid, then increased after hydroxide back titration. The varied ratio of signal intensity between (IV)Al and (VI)Al species in 27Al MAS NMR spectra, together with the stable BET surface area after acidimetric titration, suggested that edge faces and basal planes in the layer structure of illite participated in dissolution of structural components. The combined spectroscopic evidence demonstrated that the reactions between illite surfaces and acid-leaching silicic acid and aluminum ions should be considered in the model description of surface acid-base properties of the aqueous illite.

  17. Developing a Physiotherapy-Specific Preliminary Clinical Decision-Making Tool for Oxygen Titration: A Modified Delphi Study

    Science.gov (United States)

    Duong, Michelle; Bertin, Kendra; Henry, Renee; Singh, Deepti; Timmins, Nolla; Brooks, Dina; Mathur, Sunita

    2014-01-01

    ABSTRACT Purpose: To develop and evaluate a preliminary clinical decision-making tool (CDMT) to assist physiotherapists in titrating oxygen for acutely ill adults in Ontario. Methods: A panel of 14 experienced cardiorespiratory physiotherapists was recruited. Factors relating to oxygen titration were identified using a modified Delphi technique. Four rounds of questionnaires were conducted, during which the goals were to (1) generate factors, (2) reduce factors and debate contentious factors, (3) finalize factors and develop the preliminary CDMT, and (4) evaluate the usability of the tool in a clinical context. Results: The panel reached consensus on a total of 89 factors, which were compiled to create the preliminary CDMT. The global tool reached consensus for sensibility, receiving a mean score of 6/7 on a 7-point Likert-type scale (1=unacceptable; 7=excellent). Five of the nine individual components of evaluation of the tool achieved scores ≥6.0; the remaining four had mean scores between 5.4 and 5.9. Conclusion: This study produced a preliminary CDMT for oxygen titration, which the panel agreed was highly comprehensible and globally sensible. Further research is necessary to evaluate the sensibility and applicability of the tool in a clinical setting. PMID:25125782

  18. Stabilization of the initial electrochemical potential for a metal-based potentiometric titration study of a biosorption process.

    Science.gov (United States)

    Naja, Ghinwa; Mustin, Christian; Volesky, Bohumil; Berthelin, Jacques

    2006-01-01

    An interactive metal-based potentiometric titration method has been developed using an ion selective electrode for studying the sorption of metal cations. The accuracy of this technique was verified by analyzing the metal sorption mechanism for the biomass of Rhizopus arrhizus fungus and diatomite, two dissimilar materials (organic and mineral, strong sorbent and weak sorbent) of a different order of cation exchange capacity. The problem of the initial electrochemical potential was addressed identifying the usefulness of a Na-sulfonic resin as a strong chelating agent applied before the beginning of sorption titration experiments so that the titration curves and the sorption uptake could be quantitatively compared. The resin stabilized the initial electrochemical potential to -405+/-5 mV corresponding to 2 micro gl(-1) of lead concentration in solution. The amounts of lead sorbed by R. arrhizus biomass and diatomite were 0.9 mmol g(-1) (C(e)=5.16 x 10(-2)mM) and 0.052 mmol g(-1) (C(e)=5.97 x 10(-2) mM), respectively. Lead sorption by the fungal biomass was pinpointed to at least two types of chemical active sites. The first type was distinguished by high reactivity and a low number of sites whereas the other was characterized by their higher number and lower reactivity.

  19. A Phase II dose titration study of thalidomide for cancer-associated anorexia.

    Science.gov (United States)

    Davis, Mellar; Lasheen, Wael; Walsh, Declan; Mahmoud, Fade; Bicanovsky, Leslie; Lagman, Ruth

    2012-01-01

    Sixty-five percent of people with advanced cancer suffers from loss of appetite. Several inflammatory cytokines appear to cause appetite loss in animal models. Thalidomide is an immunomodulatory drug that has been associated with improved appetite in those with HIV infections and cancer. We completed a two-stage Phase II dose titration study of thalidomide, the primary purpose of which was to assess appetite response to thalidomide in cancer-associated anorexia. Individuals older than 18 years of age with active cancer, loss of appetite by numerical rating scale (NRS), life expectancy of at least four weeks, and Eastern Cooperative Oncology Group performance status of 0-3 were entered into the study. Pretreatment screening included medical history, neurologic examination, and symptoms by NRS and categorical scale (CAT). Patients received 50mg of thalidomide by mouth at bedtime for two weeks. Individuals who did not respond were dose escalated to 100mg at night for two weeks. Assessment of appetite, early satiety, fatigue, insomnia, night sweats, pain, and quality of life (QOL) occurred at two-week intervals. Toxicity also was assessed. The primary outcome was appetite response defined as a two-point reduction in the NRS or a one-point improvement in the CAT. Thirty-five patients entered the study; 33 completed 14 days of therapy and were analyzed for efficacy and toxicity. Sixty-four percent who completed at least two weeks of thalidomide had improved appetite. The CAT scores for appetite, insomnia, and QOL improved significantly. The 95% confidence intervals did not overlap. Five participants dropped out because of toxicity: two before two weeks and three later. Thalidomide reduced multiple symptoms commonly associated with cancer-related anorexia and improved QOL. Our findings confirmed and validated a previously published single-arm trial. A recent randomized trial demonstrated greater benefits when thalidomide is used combined with other agents to treat cancer

  20. Oxygen titration after resuscitation from out-of-hospital cardiac arrest: a multi-centre, randomised controlled pilot study (the EXACT pilot trial).

    Science.gov (United States)

    Bray, Janet E; Hein, Cindy; Smith, Karen; Stephenson, Michael; Grantham, Hugh; Finn, Judith; Stub, Dion; Cameron, Peter

    2018-04-20

    Recent studies suggest the administration of 100% oxygen to hyperoxic levels following return-of-spontaneous-circulation (ROSC) post-cardiac arrest may be harmful. However, the feasibility and safety of oxygen titration in the prehospital setting is unknown. We conducted a multi-centre, phase-2 study testing whether prehospital titration of oxygen results in an equivalent number of patients arriving at hospital with oxygen saturations SpO2 ≥ 94%. We enrolled unconscious adults with: sustained ROSC; initial shockable rhythm; an advanced airway; and an SpO2 ≥ 95%. Initially (Sept 2015-March 2016) patients were randomised 1:1 to either 2 litres/minute (L/min) oxygen (titrated) or >10 L/min oxygen (control) via a bag-valve reservoir. However, one site experienced a high number of desaturations (SpO2 titrated arm and this arm was changed (April 2016) to an initial reduction of oxygen to 4 L/min then, if tolerated, to 2 L/min, and the desaturation limit was decreased to titrated (n = 37: 2L/min = 20 and 2-4 L/min = 17) oxygen or control (n = 24). Patients allocated to titrated oxygen were more likely to desaturate compared to controls ((SpO2 titrated: 90% vs. control: 100%) and all patients had a SpO2 ≥ 90%. One patient (control) re-arrested. Survival to hospital discharge was similar. Oxygen titration post-ROSC is feasible in the prehospital environment, but incremental titration commencing at 4L/min oxygen flow may be needed to maintain an oxygen saturation >90% (NCT02499042). Copyright © 2018. Published by Elsevier B.V.

  1. Impact of systolic blood pressure on the safety and tolerability of initiating and up-titrating sacubitril/valsartan in patients with heart failure and reduced ejection fraction: insights from the TITRATION study.

    Science.gov (United States)

    Senni, Michele; McMurray, John J V; Wachter, Rolf; McIntyre, Hugh F; Anand, Inder S; Duino, Vincenzo; Sarkar, Arnab; Shi, Victor; Charney, Alan

    2018-03-01

    The TITRATION trial investigated two strategies to initiate and up-titrate sacubitril/valsartan (LCZ696) to the same target dose, over a condensed (3-week) or conservative (6-week) period, in patients with heart failure with reduced ejection fraction (HFrEF) and systolic blood pressure (SBP) of ≥100 mmHg. This post hoc analysis examined the relationship between baseline SBP at screening and achievement of the target dose of sacubitril/valsartan of 97 mg/103 mg (also termed 'LCZ696 200 mg') twice per day during the study. Patients (n = 498) were categorized in four groups based on SBP at screening: 100-110 mmHg (n = 70); 111-120 mmHg (n = 93); 121-139 mmHg (n = 168) and ≥140 mmHg (n = 167). Overall, 72.7%, 76.1%, 85.6% and 82.9%, respectively, of patients in these SBP categories achieved and maintained the target dose of sacubitril/valsartan without down-titration/dose interruption over 12 weeks ('treatment success'). Compared with patients with SBP of 100-110 mmHg, rates of treatment success among patients in the higher SBP groups [111-120 mmHg (P = 0.96); 121-139 mmHg (P = 0.06) and ≥140 mmHg (P = 0.25)] did not differ significantly. A higher percentage of patients with lower SBP (100-110 mmHg) achieved treatment success with gradual up-titration (6 weeks) (∼80%) than with rapid up-titration (∼69%). Similar findings were observed with regard to 'tolerability success' (maintenance of the target dose for at least the final 2 weeks prior to study completion). Hypotension occurred more frequently in patients with lower SBP. The majority of patients (>80%) with SBP of ≥100 mmHg achieved and maintained the target dose of sacubitril/valsartan if the treatment was titrated gradually. These findings suggest that low SBP should not prevent clinicians from considering the initiation of sacubitril/valsartan. © 2017 The Authors. European Journal of Heart Failure © 2017 European Society of

  2. Protocol adherence for continuously titrated interventions in randomized trials: an overview of the current methodology and case study

    Directory of Open Access Journals (Sweden)

    F. Lauzier

    2017-07-01

    Full Text Available Abstract Background The standard definition for protocol adherence is the proportion of all scheduled doses that are delivered. In clinical research, this definition has several limitations when evaluating protocol adherence in trials that study interventions requiring continuous titration. Discussion Building upon a specific case study, we analyzed a recent trial of a continuously titrated intervention to assess the impact of different definitions of protocol deviations on the interpretation of protocol adherence. The OVATION pilot trial was an open-label randomized controlled trial of higher (75–80 mmHg versus lower (60–65 mmHg mean arterial pressure (MAP targets for vasopressor therapy in shock. In this trial, potential protocol deviations were defined as MAP values outside the targeted range for >4 consecutive hours during vasopressor therapy without synchronous and consistent adjustments of vasopressor doses. An adjudication committee reviewed each potential deviation to determine if it was clinically-justified or not. There are four reasons for this contextual measurement and reporting of protocol adherence. First, between-arm separation is a robust measure of adherence to complex protocols. Second, adherence assessed by protocol deviations varies in function of the definition of deviations and the frequency of measurements. Third, distinguishing clinically-justified vs. not clinically-justified protocol deviations acknowledges clinically sensible bedside decision-making and offers a clear terminology before the trial begins. Finally, multiple metrics exist to report protocol deviations, which provides different information but complementary information on protocol adherence. Conclusions In trials of interventions requiring continuous titration, metrics used for defining protocol deviations have a considerable impact on the interpretation of protocol adherence. Definitions for protocol deviations should be prespecified and correlated

  3. Protocol adherence for continuously titrated interventions in randomized trials: an overview of the current methodology and case study.

    Science.gov (United States)

    Lauzier, F; Adhikari, N K; Seely, A; Koo, K K Y; Belley-Côté, E P; Burns, K E A; Cook, D J; D'Aragon, F; Rochwerg, B; Kho, M E; Oczkowksi, S J W; Duan, E H; Meade, M O; Day, A G; Lamontagne, F

    2017-07-17

    The standard definition for protocol adherence is the proportion of all scheduled doses that are delivered. In clinical research, this definition has several limitations when evaluating protocol adherence in trials that study interventions requiring continuous titration. Building upon a specific case study, we analyzed a recent trial of a continuously titrated intervention to assess the impact of different definitions of protocol deviations on the interpretation of protocol adherence. The OVATION pilot trial was an open-label randomized controlled trial of higher (75-80 mmHg) versus lower (60-65 mmHg) mean arterial pressure (MAP) targets for vasopressor therapy in shock. In this trial, potential protocol deviations were defined as MAP values outside the targeted range for >4 consecutive hours during vasopressor therapy without synchronous and consistent adjustments of vasopressor doses. An adjudication committee reviewed each potential deviation to determine if it was clinically-justified or not. There are four reasons for this contextual measurement and reporting of protocol adherence. First, between-arm separation is a robust measure of adherence to complex protocols. Second, adherence assessed by protocol deviations varies in function of the definition of deviations and the frequency of measurements. Third, distinguishing clinically-justified vs. not clinically-justified protocol deviations acknowledges clinically sensible bedside decision-making and offers a clear terminology before the trial begins. Finally, multiple metrics exist to report protocol deviations, which provides different information but complementary information on protocol adherence. In trials of interventions requiring continuous titration, metrics used for defining protocol deviations have a considerable impact on the interpretation of protocol adherence. Definitions for protocol deviations should be prespecified and correlated with between-arm separation, if it can be measured.

  4. A brief survey of patients' first impression after CPAP titration predicts future CPAP adherence: a pilot study.

    Science.gov (United States)

    Balachandran, Jay S; Yu, Xiaohong; Wroblewski, Kristen; Mokhlesi, Babak

    2013-03-15

    CPAP adherence patterns are often established very early in the course of therapy. Our objective was to quantify patients' perception of CPAP therapy using a 6-item questionnaire administered in the morning following CPAP titration. We hypothesized that questionnaire responses would independently predict CPAP adherence during the first 30 days of therapy. We retrospectively reviewed the CPAP perception questionnaires of 403 CPAP-naïve adults who underwent in-laboratory titration and who had daily CPAP adherence data available for the first 30 days of therapy. Responses to the CPAP perception questionnaire were analyzed for their association with mean CPAP adherence and with changes in daily CPAP adherence over 30 days. Patients were aged 52 ± 14 years, 53% were women, 54% were African American, the mean body mass index (BMI) was 36.3 ± 9.1 kg/m(2), and most patients had moderate-severe OSA. Four of 6 items from the CPAP perception questionnaire- regarding difficulty tolerating CPAP, discomfort with CPAP pressure, likelihood of wearing CPAP, and perceived health benefit-were significantly correlated with mean 30-day CPAP adherence, and a composite score from these 4 questions was found to be internally consistent. Stepwise linear regression modeling demonstrated that 3 variables were significant and independent predictors of reduced mean CPAP adherence: worse score on the 4-item questionnaire, African American race, and non-sleep specialist ordering polysomnogram and CPAP therapy. Furthermore, a worse score on the 4-item CPAP perception questionnaire was consistently associated with decreased mean daily CPAP adherence over the first 30 days of therapy. In this pilot study, responses to a 4-item CPAP perception questionnaire administered to patients immediately following CPAP titration independently predicted mean CPAP adherence during the first 30 days. Further prospective validation of this questionnaire in different patient populations is warranted.

  5. A Brief Survey of Patients' First Impression after CPAP Titration Predicts Future CPAP Adherence: A Pilot Study

    Science.gov (United States)

    Balachandran, Jay S.; Yu, Xiaohong; Wroblewski, Kristen; Mokhlesi, Babak

    2013-01-01

    Background: CPAP adherence patterns are often established very early in the course of therapy. Our objective was to quantify patients' perception of CPAP therapy using a 6-item questionnaire administered in the morning following CPAP titration. We hypothesized that questionnaire responses would independently predict CPAP adherence during the first 30 days of therapy. Methods: We retrospectively reviewed the CPAP perception questionnaires of 403 CPAP-naïve adults who underwent in-laboratory titration and who had daily CPAP adherence data available for the first 30 days of therapy. Responses to the CPAP perception questionnaire were analyzed for their association with mean CPAP adherence and with changes in daily CPAP adherence over 30 days. Results: Patients were aged 52 ± 14 years, 53% were women, 54% were African American, the mean body mass index (BMI) was 36.3 ± 9.1 kg/m2, and most patients had moderate-severe OSA. Four of 6 items from the CPAP perception questionnaire— regarding difficulty tolerating CPAP, discomfort with CPAP pressure, likelihood of wearing CPAP, and perceived health benefit—were significantly correlated with mean 30-day CPAP adherence, and a composite score from these 4 questions was found to be internally consistent. Stepwise linear regression modeling demonstrated that 3 variables were significant and independent predictors of reduced mean CPAP adherence: worse score on the 4-item questionnaire, African American race, and non-sleep specialist ordering polysomnogram and CPAP therapy. Furthermore, a worse score on the 4-item CPAP perception questionnaire was consistently associated with decreased mean daily CPAP adherence over the first 30 days of therapy. Conclusions: In this pilot study, responses to a 4-item CPAP perception questionnaire administered to patients immediately following CPAP titration independently predicted mean CPAP adherence during the first 30 days. Further prospective validation of this questionnaire in different

  6. Nuclear magnetic resonance titration studies of simple host-guest amine-carboxylic acid systems

    International Nuclear Information System (INIS)

    Mahinay, Myrna S.; Lindoy, Leonard F.

    1999-01-01

    Adduct formation for the open-chain 1,2-diaminoethane and its N-methyl derivatives [N,N-dimethyl-ethylenediamine (N,N-DMEN),N,N'-dimethylethylenediamine (N,N'-DMEN);N,N,N',N'-tetramethyl-ethylenediamine (N,N,N',N'-TMEN)]; 1,4-diaminobutane; diethylenetriamine (DIEN); triethylenetramine (TRIEN); and the carboxylic acid systems in polar CD 3 OH and nonpolar CDCl 3 solvents were elucidated by nmr titration. The stoichiometries of the adducts were found to correspond to the number of nitrogen present in the amine species with the exception of ligand incorporating N-donors of low basicity; that is, whose log K values for the protonated species in water were less than approximately 6 to 7.(Author)

  7. Titrating the Cost of Plant Toxins Against Predators: a Case Study with Common Duikers, Sylvicapra grimmia.

    Science.gov (United States)

    Abu Baker, Mohammad A

    2015-10-01

    Foragers face many variables that influence their food intake. These may include habitat structure, time, climate, resource characteristic, food quality, and plant defenses. I conducted foraging experiments using common duikers that involved: 1) testing the effect of plant toxins on foraging, and 2) titrating toxin intake against safety. I used giving up densities (GUDs, food remaining after foraging) to test for selection among trays containing alfalfa pellets treated with water, with 10% oxalic acid, or 10% quebracho tannin. Pairs of trays were placed within islands of woody vegetation and out in open grass. I also conducted a titration experiment by offering the duikers a choice between a patch with water-treated pellets placed at a risky site, or a patch with one of three oxalic acid-treated pellets at a safe site. This made it possible to determine the concentration of oxalic acid at which the cost of toxin in the safe site equals the predation cost at the risky site. The common duikers showed no selectivity among the three treatments at 10% concentration, however, GUDs in the open grass (i.e., safe) were significantly lower than in the wooded islands (i.e., risky). As the oxalic acid concentration increased at the safe sites, the duiker's food intake from the risky sites increased significantly. The results demonstrate that foraging hazards may come in different forms such as predation and plant toxins, and their interactions may alter habitat use, foraging patterns, and perceptions of risk. These variables occur under natural situations, altering the overall habitat quality.

  8. Studies of factors affecting uranium determinations by automated coulometric titration (New Brunswick Laboratory/Davies--Gray Method)

    International Nuclear Information System (INIS)

    Harrar, J.E.; Boyle, W.G.

    1976-01-01

    The method's errors are defined to ascertain its absolute accuracy. An analytical technique was developed to examine vanadyl sulfate diluent for vanadium (V). None could be found in any of the lots tested. Certain lots of reagent-grade phosphoric acid contained an unidentified impurity that caused high generator-electrode potentials and a positive error. The current-potential characteristics of the generator electrode were measured. The data indicated that a significant fraction of uranium (IV) was oxidized directly during the early stages of titration. Using equations theoretically applicable to such a titration, a negligible difference was found between the inflection point of the titration curve and the equivalence point in the titration. However, the actual experimental curves did not agree with the theoretical curves early in the titration. Measurements of the background current indicated a level equivalent to approximately 0.2 mg uranium. The evaluation of the reagent delivery system used in the automated analyzer revealed adequate reproducibility. 8 tables

  9. Study of complexing of rare earths with ethylenediaminedisuccinic acid by the method of pH-metric titration

    International Nuclear Information System (INIS)

    Muratova, N.M.; Martynenko, L.I.

    1979-01-01

    The pH-metric titration technique was used to study the possibility of formation of higher complexes between rare earth elements of the whole series and ethylenediaminedisuccinic acid (L). The logarithms of stability constants were determined for LaL - (10.95), PrL - (11.30), NdL - (11.35), ErL 2 5- (4.10), TuL 2 5- (4.00), YbL 2 5- (4.25) and LnL 2 5- (4.8). In the concentrations studied only heavy lanthanides were forming unstable bis-ethylenediaminedisuccinates. Lighter rare earth elements did not form higher complexes even when the ligand was in four-fold excess; however, the complexes did appear in more concentrated solutions

  10. Isothermal titration calorimetric studies of the acid-base properties of poly(N-isopropylacrylamide-co-4-vinylpyridine) cationic polyelectrolyte colloidal microgels

    International Nuclear Information System (INIS)

    Seidel, J.; Pinkrah, V.T.; Mitchell, J.C.; Chowdhry, B.Z.; Snowden, M.J.

    2004-01-01

    Isothermal titration calorimetry (ITC) and potentiometric titration were used to study the protonation properties of the 4-vinylpyridine (4-VP) moiety in cationic poly(N-isopropylacrylamide-co-4-vinylpyridine) colloidal microgels [poly(NIPAM-co-4-VP)]. Calorimetric pH titrations were performed using microgels of different 4-VP content and the influence of ionic strength and counter ions have been examined. The calorimetric titration output consists of several thermal contributions reflecting the complex nature of the interactions in the aqueous microgel dispersions. In contrast to the potentiometric results, the calorimetric titration data could not be completely described by a theoretical model solely taking into account protonation equilibria. Deviations from the proposed model correlate with swelling or shrinking of the gel particles. The calorimetric results also reveal a pronounced counter-ion effect of perchlorate compared to chloride ions. In the presence of perchlorate ions, small secondary thermal effects accompany protonation of the 4-VP moiety due, in part, to kinetically limited conformational changes in the co-polymer microgel

  11. TITRATION: A Randomized Study to Assess 2 Treatment Algorithms with New Insulin Glargine 300 units/mL.

    Science.gov (United States)

    Yale, Jean-François; Berard, Lori; Groleau, Mélanie; Javadi, Pasha; Stewart, John; Harris, Stewart B

    2017-10-01

    It was uncertain whether an algorithm that involves increasing insulin dosages by 1 unit/day may cause more hypoglycemia with the longer-acting insulin glargine 300 units/mL (GLA-300). The objective of this study was to compare safety and efficacy of 2 titration algorithms, INSIGHT and EDITION, for GLA-300 in people with uncontrolled type 2 diabetes mellitus, mainly in a primary care setting. This was a 12-week, open-label, randomized, multicentre pilot study. Participants were randomly assigned to 1 of 2 algorithms: they either increased their dosage by 1 unit/day (INSIGHT, n=108) or the dose was adjusted by the investigator at least once weekly, but no more often than every 3 days (EDITION, n=104). The target fasting self-monitored blood glucose was in the range of 4.4 to 5.6 mmol/L. The percentages of participants reaching the primary endpoint of fasting self-monitored blood glucose ≤5.6 mmol/L without nocturnal hypoglycemia were 19.4% (INSIGHT) and 18.3% (EDITION). At week 12, 26.9% (INSIGHT) and 28.8% (EDITION) of participants achieved a glycated hemoglobin value of ≤7%. No differences in the incidence of hypoglycemia of any category were noted between algorithms. Participants in both arms of the study were much more satisfied with their new treatment as assessed by the Diabetes Treatment Satisfaction Questionnaire. Most health-care professionals (86%) preferred the INSIGHT over the EDITION algorithm. The frequency of adverse events was similar between algorithms. A patient-driven titration algorithm of 1 unit/day with GLA-300 is effective and comparable to the previously tested EDITION algorithm and is preferred by health-care professionals. Copyright © 2017 Diabetes Canada. Published by Elsevier Inc. All rights reserved.

  12. Cell surface groups of two picocyanobacteria strains studied by zeta potential investigations, potentiometric titration, and infrared spectroscopy.

    Science.gov (United States)

    Dittrich, Maria; Sibler, Sabine

    2005-06-15

    In order to clarify the role of picocyanobacteria in aquatic biogeochemical processes (e.g., calcite precipitation), cell surface properties need to be investigated. An experimental study of the cell surface characteristics of two Synechococcus-type unicellular autotrophic picocyanobacterial strains was carried out. One strain was isolated from Lake Plon and contained phycocyanin, the other strain came from Lago Maggiore and was rich in phycoerythrin. Potentiometric titrations were conducted to determine the different types of sites present on the bacteria cell walls. Infrared spectroscopy allowed characterization of the various functional groups (RNH(2), RCOOH, ROH, RPO(2)) and investigations of zeta potential provided insight into the isoelectrical points of the strains. Titrations reveal three distinct sites on the bacterial surfaces of phycocyanin- and phycoerythrin-rich strains with pK values of 4.8+/-0.3/5.0+/-0.2, 6.6+/-0.2/6.7+/-0.4, and 8.8+/-0.1/8.7+/-0.2, corresponding to carboxyl, phosphate, and amine groups with surface densities of 2.6+/-0.4/7.4+/-1.6 x 10(-4), 1.9+/-0.5/4.4+/-0.8 x 10(-4), and 2.5+/-0.4/4.8+/-0.7 x 10(-4) mol/g of dry bacteria. The deprotonation constants are similar to those of bacterial strains and site densities are also within an order of magnitude of other strains. The phycoerythrin-rich strain had a higher number of binding sites than the phycocyanin-rich strain. The results showed that picocyanobacteria may adsorb either calcium cations or carbonate anions and therefore strongly influence the biogeochemical cycling of calcite in pelagic systems.

  13. Fluorescence-Based Comparative Binding Studies of the Supramolecular Host Properties of PAMAM Dendrimers Using Anilinonaphthalene Sulfonates: Unusual Host-Dependent Fluorescence Titration Behavior

    Directory of Open Access Journals (Sweden)

    Natasa Stojanovic

    2010-04-01

    Full Text Available This work describes the fluorescence enhancement of the anilinonaphthalene sulfonate probes 1,8-ANS, 2,6-ANS, and 2,6-TNS via complexation with PAMAM dendrimer hosts of Generation 4, 5 and 6. The use of this set of three very closely related probes allows for comparative binding studies, with specific pairs of probes differing only in shape (1,8-ANS and 2,6-ANS, or in the presence of a methyl substituent (2,6-TNS vs. 2,6-ANS. The fluorescence of all three probes was significantly enhanced upon binding with PAMAM dendrimers, however in all cases except one, a very unusual spike was consistently observed in the host fluorescence titration plots (fluorescence enhancement vs. host concentration at low dendrimer concentration. This unprecedented fluorescence titration curve shape makes fitting the data to a simple model such as 1:1 or 2:1 host: guest complexation very difficult; thus only qualitative comparisons of the relative binding of the three guests could be made based on host titrations. In the case of G4 and G5 dendrimers, the order of binding strength was qualitatively determined to be 1,8-ANS < 2,6-ANS indicating that the more streamlined 2,6-substituted probes are a better match for the dendrimer cavity shape than the bulkier 1,8-substituted probe. This order of binding strength was also indicated by double fluorometric titration experiments, involving both host and guest titrations. Further double fluorometric titration experiments on 2,6-ANS in G4 dendrimer revealed a host concentration-dependent change in the nature of the host: guest complexation, with multiple guests complexed per host molecule at very low host concentrations, but less than one guest per host at higher concentrations.

  14. The Effect of Metal Concentration on the Parameters Derived from Complexometric Titrations of Trace Elements in Seawater—A Model Study

    NARCIS (Netherlands)

    Gledhill, M.; Gerringa, L.J.A.

    2017-01-01

    In this study we examine the impact of dissolved metal concentrations on the parametersthat are commonly determined from complexometric titrations in seawater. We use thenon-ideal competitive adsorption (NICA) model within the framework of the chemicalspeciation program visual MINTEQ with iron as a

  15. Understanding binding affinity : A combined isothermal titration calorimetry/molecular dynamics study of the binding of a series of hydrophobically modified benzamidinium chloride inhibitors to trypsin

    NARCIS (Netherlands)

    Talhout, Reinskje; Villa, Alessandra; Mark, AE; Engberts, JBFN

    2003-01-01

    The binding of a series of p-alkylbenzamidinium chloride inhibitors to the serine proteinase trypsin over a range of temperatures has been studied using isothermal titration (micro)calorimetry and molecular dynamics simulation techniques. The inhibitors have small structural variations at the para

  16. Study population and treatment titration in the International Nifedipine GITS Study: Intervention as a Goal in Hypertension Treatment (INSIGHT).

    Science.gov (United States)

    Brown, M J; Castaigne, A; de Leeuw, P W; Mancia, G; Rosenthal, T; Ruilope, L M

    1998-12-01

    To ascertain the baseline characteristics of the high-risk hypertensive patients entering the International Nifedipine GITS Study: Intervention as a Goal in Hypertension Treatment (INSIGHT). To determine the success of single and combination therapy in achieving target blood pressures in such a population. INSIGHT is a double-blind, prospective outcome trial comparing the efficacy of the calcium channel blocker, nifedipine GITS, and the thiazide, co-amilozide, in preventing myocardial infarction and stroke. We recruited 2996 men and 3454 women, aged 55-80 years, with blood pressure during placebo run-in >150/95 mmHg or isolated systolic blood pressure >160 mmHg from nine countries. Treatment allocation to nifedipine GITS 30 mg daily or co-amilozide (hydrochlorothiazide 25 mg/amiloride 5 mg) once daily was performed by minimization rather than randomization to balance additional risk factors. This was followed by four optional increases in treatment: dose-doubling of the primary drug, addition of atenolol 25/50 mg or enalapril 5/10 mg, and then any other hypotensive drug excluding calcium blockers or diuretics. Target blood pressure was 140/90 mmHg or a fall > or = 20/10 mmHg. Blood pressure at randomization was 172+/-15 / 99+/-9 mmHg. Thirteen per cent of the patients were previously untreated. The proportions of each additional risk factors were: smoking > 10/day, 29%; cholesterol > 6.43 mmol/l, 52%; family history of premature myocardial infarction or stroke, 21%; diabetes mellitus 20%; left ventricular hypertrophy, 10%; previous myocardial infarction, other presentations of coronary heart disease, and peripheral vascular disease, each 6%; proteinuria, 3%. Fifty-five per cent of patients had one additional risk factor, whereas 33%, 9% and 3% had two, three or more additional risk factors, respectively. The blood pressure (and falls in blood pressure) at the end of titration and at 1 year after minimization was 139+/-12 / 82+/-7 mmHg (33+/-15 / 17+/-9) in the 5226

  17. Potentiometric titration of plutonium

    International Nuclear Information System (INIS)

    Silver, G.L.

    1978-01-01

    In the potentiometric titration of plutonium(III), it has been customary to take the equivalence point as the inflection point on a plot of potential vs. volume of titrant. It have not been, however, demonstrated, that the stoichiometric end point corresponds to the inflection point. Suggestions are made according to which these points may not correspond in the potentiometric titration of plutonium(III), as these titrations are ordinarily concluded in a period of time which is short compared to the time required for valence state rearrangement through disproportionation. (T.G.)

  18. Study of neurontin: titrate to effect, profile of safety (STEPS) trial: a narrative account of a gabapentin seeding trial.

    Science.gov (United States)

    Krumholz, Samuel D; Egilman, David S; Ross, Joseph S

    2011-06-27

    Seeding trials, clinical studies conducted by pharmaceutical companies for marketing purposes, have rarely been described in detail. We examined all documents relating to the clinical trial Study of Neurontin: Titrate to Effect, Profile of Safety (STEPS) produced during the Neurontin marketing, sales practices, and product liability litigation, including company internal and external correspondence, reports, and presentations, as well as depositions elicited in legal proceedings of Harden Manufacturing vs Pfizer and Franklin vs Warner-Lambert, most which were created between 1990 and 2009. Using a systematic search strategy, we identified and reviewed all documents related to the STEPS trial in order to identify key themes related to the trial's conduct and determine the extent of marketing involvement in its planning and implementation. Documents demonstrated that STEPS was a seeding trial posing as a legitimate scientific study. Documents consistently described the trial itself, not trial results, to be a marketing tactic in the company's marketing plans. Documents demonstrated that at least 2 external sources questioned the validity of the study before execution, and that data quality during the study was often compromised. Furthermore, documents described company analyses examining the impact of participating as a STEPS investigator on rates and dosages of gabapentin prescribing, finding a positive association. None of these findings were reported in 2 published articles. The STEPS trial was a seeding trial, used to promote gabapentin and increase prescribing among investigators, and marketing was extensively involved in its planning and implementation.

  19. Safety of the Up-titration of Nifedipine GITS and Valsartan or Low-dose Combination in Uncontrolled Hypertension: the FOCUS Study.

    Science.gov (United States)

    Park, Jeong Bae; Shin, Joon-Han; Kim, Dong-Soo; Youn, Ho-Joong; Park, Seung Woo; Shim, Wan Joo; Park, Chang Gyu; Kim, Dong-Woon; Lee, Hae-Young; Choi, Dong-Ju; Rim, Se-Joong; Lee, Sung-Yun; Kim, Ju-Han

    2016-04-01

    Doubling the dose of antihypertensive drugs is necessary to manage hypertension in patients whose disease is uncontrolled. However, this strategy can result in safety issues. This study compared the safety and efficacy of up-titration of the nifedipine gastrointestinal therapeutic system (GITS) with up-titration of valsartan monotherapy; these were also compared with low-dose combinations of the two therapies. This prospective, open-label, randomized, active-controlled, multicenter study lasted 8 weeks. If patients did not meet the target blood pressure (BP) after 4 weeks of treatment with low-dose monotherapy, they were randomized to up-titration of the nifedipine GITS dose from 30 mg (N30) to 60 mg or valsartan from 80 mg to 160 mg or they were randomized to receive a low-dose combination of N30 and valsartan 80 mg for another 4 weeks. BP variability was assessed by using the SD or the %CV of the short-term BP measured at clinic. Of the 391 patients (20~70 years with stage II or higher hypertension) screened for study inclusion, 362 patients who had 3 BP measurements were enrolled. The reduction in the mean systolic/diastolic BP from baseline to week 4 was similar in both low-dose monotherapy groups with either N30 or valsartan 80 mg. BP variability (SD) was unchanged with either therapy, but the %CV was slightly increased in the N30 group. There was no significant difference in BP variability either in SD or %CV between responders and nonresponders to each monotherapy despite the significant difference in the mean BP changes. The up-titration effect of nifedipine GTS from 30 to 60 mg exhibited an additional BP reduction, but this effect was not shown in the up-titration of valsartan from 80 to 160 mg. Although the difference in BP was obvious between high-dose nifedipine GTS and valsartan, the BP variability was unchanged between the 2 drugs and was similar to the low-dose combinations. There was a low rate of adverse events in all treatment groups. In addition

  20. Assessment of Knowledge of Self Blood Glucose Monitoring and Extent of Self Titration of Anti-Diabetic Drugs among Diabetes Mellitus Patients - A Cross Sectional, Community Based Study.

    Science.gov (United States)

    Krishnan, V; Thirunavukkarasu, J

    2016-03-01

    Self blood glucose monitoring is an important context of self care in the management of diabetes mellitus. All the guidelines must be followed while performing self blood glucose monitoring and tracking of values is essential to facilitate the physician while titrating the drugs and /or doses of anti diabetes medication. Self titration by patients following self monitoring must be discouraged. To assess the knowledge and practice of self blood glucose monitoring among diabetes patients and extent of self titration of anti diabetes medicines among diabetes patients based on self blood glucose monitoring. This pilot, cross-sectional, observational study was conducted using a validated questionnaire among adult male and female diabetes patients performing self blood glucose monitoring at home. Diabetes patients with complications and juvenile diabetes patients were excluded. Out of 153 patients surveyed, only 37 (24.1%) (20 males, 17 females) patients were aware and have been following self blood glucose monitoring appropriately. About 116 (75.8%) (64 males, 52 females) of patients were devoid of adequate knowledge and did not practice self blood glucose monitoring in a proper way. Ninety eight (64.05%) accepted that they self titrate their anti diabetic medicines based on self monitoring. Self monitoring of blood glucose should be encouraged and patients should be taught importance of following correct steps and tracking of self monitoring by physician or diabetes educator.

  1. Automated uranium titration system

    International Nuclear Information System (INIS)

    Takahashi, M.; Kato, Y.

    1983-01-01

    An automated titration system based on the Davies-Gray method has been developed for accurate determination of uranium. The system consists of a potentiometric titrator with precise burettes, a sample changer, an electronic balance and a desk-top computer with a printer. Fifty-five titration vessels are loaded in the sample changer. The first three contain the standard solution for standardizing potassium dichromate titrant, and the next two and the last two contain the control samples for data quality assurance. The other forty-eight measurements are carried out for sixteen unknown samples. Sample solution containing about 100 mg uranium is taken in a titration vessel. At the pretreatment position, uranium (VI) is reduced to uranium (IV) by iron (II). After the valency adjustment, the vessel is transferred to the titration position. The rate of titrant addition is automatically controlled to be slower near the end-point. The last figure (0.01 mL) of the equivalent titrant volume for uranium is calculated from the potential change. The results obtained with this system on 100 mg uranium gave a precision of 0.2% (RSD,n=3) and an accuracy of better than 0.1%. Fifty-five titrations are accomplished in 10 hours. (author)

  2. Design of a multicentre randomized controlled trial to assess the safety and efficacy of dose titration by specialized nurses in patients with heart failure. ETIFIC study protocol.

    Science.gov (United States)

    Oyanguren, Juana; García-Garrido, LLuisa; Nebot Margalef, Magdalena; Lekuona, Iñaki; Comin-Colet, Josep; Manito, Nicolás; Roure, Julia; Ruiz Rodriguez, Pilar; Enjuanes, Cristina; Latorre, Pedro; Torcal Laguna, Jesús; García-Gutiérrez, Susana

    2017-11-01

    Heart failure (HF) is associated with many hospital admissions and relatively high mortality, rates decreasing with administration of beta-blockers (BBs), angiotensin-converting-enzyme inhibitors, angiotensin II receptor blockers, and mineralocorticoid receptor antagonists. The effect is dose dependent, suboptimal doses being common in clinical practice. The 2012 European guidelines recommend close monitoring and dose titration by HF nurses. Our main aim is to compare BB doses achieved by patients after 4 months in intervention (HF nurse-managed) and control (cardiologist-managed) groups. Secondary aims include comparing doses of the other aforementioned drugs achieved after 4 months, adverse events, and outcomes at 6 months in the two groups. We have designed a multicentre (20 hospitals) non-inferiority randomized controlled trial, including patients with new-onset HF, left ventricular ejection fraction ≤40%, and New York Heart Association class II-III, with no contraindications to BBs. We will also conduct qualitative analysis to explore potential barriers to and facilitators of dose titration by HF nurses. In the intervention group, HF nurses will implement titration as prescribed by cardiologists, following a protocol. In controls, cardiologists will both prescribe and titrate doses. The study variables are doses of each of the drugs after 4 months relative to the target dose (%), New York Heart Association class, left ventricular ejection fraction, N-terminal pro B-type natriuretic peptide levels, 6 min walk distance, comorbidities, renal function, readmissions, mortality, quality of life, and psychosocial characteristics. The trial seeks to assess whether titration by HF nurses of drugs recommended in practice guidelines is safe and not inferior to direct management by cardiologists. The results could have an impact on clinical practice. © 2017 The Authors. ESC Heart Failure published by John Wiley & Sons Ltd on behalf of the European Society of

  3. Patient-led versus physician-led titration of insulin glargine in patients with uncontrolled type 2 diabetes: a randomized multinational ATLAS study.

    Science.gov (United States)

    Garg, Satish K; Admane, Karim; Freemantle, Nick; Odawara, Masato; Pan, Chang-Yu; Misra, Anoop; Jarek-Martynowa, Iwona R; Abbas-Raza, Syed; Mirasol, Roberto C; Perfetti, Riccardo

    2015-02-01

    Self-adjustment of insulin dose is commonly practiced in Western patients with type 2 diabetes but is usually not performed in Asian patients. This multinational, 24-week, randomized study compared patient-led with physician-led titration of once-daily insulin glargine in Asian patients with uncontrolled type 2 diabetes who were on 2 oral glucose-lowering agents. Patient-led (n = 275) or physician-led (n = 277) subjects followed the same dose-titration algorithm guided by self-monitored fasting blood glucose (FBG; target, 110 mg/dL [6.1 mmol/L]). The primary endpoint was change in mean glycated hemoglobin (HbA1c) at week 24 in the patient-led versus physician-led titration groups. Patient-led titration resulted in a significantly higher drop in HbA1c value at 24 weeks when compared with physician-led titration (-1.40% vs. -1.25%; mean difference, -0.15; 95% confidence interval, -0.29 to 0.00; P = .043). Mean decrease in FBG was greatest in the patient-led group (-2.85 mmol/L vs. -2.48 mmol/L; P = .001). The improvements in HbA1c and FBG were consistent across countries, with similar improvements in treatment satisfaction in both groups. Mean daily insulin dose was higher in the patient-led group (28.9 units vs. 22.2 units; Ptitration achieved near-target blood glucose levels in Asian patients with uncontrolled type 2 diabetes who were on 2 oral glucose-lowering drugs, demonstrating that Asian patients can self-uptitrate insulin dose effectively when guided.

  4. Isothermal titration calorimetric and computational studies on the binding of chitooligosaccharides to pumpkin (Cucurbita maxima) phloem exudate lectin.

    Science.gov (United States)

    Narahari, Akkaladevi; Singla, Hitesh; Nareddy, Pavan Kumar; Bulusu, Gopalakrishnan; Surolia, Avadhesha; Swamy, Musti J

    2011-04-14

    The interaction of chitooligosaccharides [(GlcNAc)(2-6)] with pumpkin phloem exudate lectin (PPL) was investigated by isothermal titration calorimetry and computational methods. The dimeric PPL binds to (GlcNAc)(3-5) with binding constants of 1.26-1.53 × 10(5) M(-1) at 25 °C, whereas chitobiose exhibits approximately 66-fold lower affinity. Interestingly, chitohexaose shows nearly 40-fold higher affinity than chitopentaose with a binding constant of 6.16 × 10(6) M(-1). The binding stoichiometry decreases with an increase in the oligosaccharide size from 2.26 for chitobiose to 1.08 for chitohexaose. The binding reaction was essentially enthalpy driven with negative entropic contribution, suggesting that hydrogen bonds and van der Waals' interactions are the main factors that stabilize PPL-saccharide association. The three-dimensional structure of PPL was predicted by homology modeling, and binding of chitooligosaccharides was investigated by molecular docking and molecular dynamics simulations, which showed that the protein binding pocket can accommodate up to three GlcNAc residues, whereas additional residues in chitotetraose and chitopentaose did not exhibit any interactions with the binding pocket. Docking studies with chitohexaose indicated that the two triose units of the molecule could interact with different protein binding sites, suggesting formation of higher order complexes by the higher oligomers of GlcNAc by their simultaneous interaction with two protein molecules.

  5. Barriers to and enablers of insulin self-titration in adults with Type 2 diabetes: a qualitative study.

    Science.gov (United States)

    McBain, H; Begum, S; Rahman, S; Mulligan, K

    2017-02-01

    To identify the barriers to and enablers of effective insulin self-titration in people with Type 2 diabetes. A qualitative semi-structured interview approach was used. Questions were structured according to the Theoretical Domains Framework, which outlines 14 domains that can act as barriers to and enablers of changing behaviour. Interviews were audio-recorded and transcribed verbatim. The data were coded according to the 14 domains, belief statements were created within each domain, and a frequency count of the most reported barriers and enablers was then carried out. Analyses were conducted by two researchers, and discrepancies agreed with a third researcher. A total of 18 adults with Type 2 diabetes took part in an interview. The majority were of South-Asian ethnicity (n = 8) and were men (n = 12). Their mean age was 61 years old. The mean duration of diabetes was 16 years and time on insulin 9 years. Inter-rater reliability for each of the domains varied (29-100%). The most frequently reported domains were Social Influence and Beliefs about Consequences; the least frequently reported were Optimism and Reinforcement. Interviewees reported receiving support to self-titrate from a range of sources. Self-titrating was perceived to have a range of both positive and negative consequences, as was not titrating. The findings highlight that those interviewed experienced a range of barriers and enablers when attempting to self-titrate. Improved education and training when initiating insulin treatment among adults with Type 2 diabetes, and throughout their journey on insulin therapy could help identify and address these barriers in order to optimize self-titration. © 2016 Diabetes UK.

  6. Use of isothermal titration calorimetry to study the interaction of short-chain alcohols with lipid membranes

    DEFF Research Database (Denmark)

    Trandum, Christa; Westh-Andersen, Peter; Jørgensen, Kent

    1999-01-01

    of short-chain alcohols on Lipid bilayers. isothermal titration calorimetry (ITC) has been used to determine the energy involved in the association of the alcohols with lipid bilayers. Pure unilamellar DMPC liposomes and DMPC liposomes incorporated with different amounts of cholesterol, sphingomyelin...... dependent on the lipid bilayer composition. In the presence of high concentrations of cholesterol, the binding enthalpy of ethanol is decreased, whereas the presence of ceramides enhances the enthalpic response of the lipid bilayer to ethanol. Isothermal titration calorimetry offers a new methodology...

  7. Titrated Misoprostol Versus Dinoprostone for Labor Induction

    African Journals Online (AJOL)

    Aim: This study designed to compare titrated misoprostol regarding its safety and efficacy with dinoprostone for induction of labor. ... Statistical analysis done using Student's t-test for quantitative data and ..... induction: A pilot study. Rev Bras ...

  8. Optimal level of continuous positive airway pressure: auto-adjusting titration versus titration with a predictive equation.

    Science.gov (United States)

    Choi, Ji Ho; Jun, Young Joon; Oh, Jeong In; Jung, Jong Yoon; Hwang, Gyu Ho; Kwon, Soon Young; Lee, Heung Man; Kim, Tae Hoon; Lee, Sang Hag; Lee, Seung Hoon

    2013-05-01

    The aims of the present study were twofold. We sought to compare two methods of titrating the level of continuous positive airway pressure (CPAP) - auto-adjusting titration and titration using a predictive equation - with full-night manual titration used as the benchmark. We also investigated the reliability of the two methods in patients with obstructive sleep apnea syndrome (OSAS). Twenty consecutive adult patients with OSAS who had successful, full-night manual and auto-adjusting CPAP titration participated in this study. The titration pressure level was calculated with a previously developed predictive equation based on body mass index and apnea-hypopnea index. The mean titration pressure levels obtained with the manual, auto-adjusting, and predictive equation methods were 9.0 +/- 3.6, 9.4 +/- 3.0, and 8.1 +/- 1.6 cm H2O,respectively. There was a significant difference in the concordance within the range of +/- 2 cm H2O (p = 0.019) between both the auto-adjusting titration and the titration using the predictive equation compared to the full-night manual titration. However, there was no significant difference in the concordance within the range of +/- 1 cm H2O (p > 0.999). When compared to full-night manual titration as the standard method, auto-adjusting titration appears to be more reliable than using a predictive equation for determining the optimal CPAP level in patients with OSAS.

  9. Study of uranium (VI) in carbonate solution by potentiometric titrations and ion-exchange

    International Nuclear Information System (INIS)

    Billon, A.

    1968-04-01

    The present work is devoted to the fixation of uranium (VI) on the conventional anion-exchange resin Dowex 2 X 8 in carbonate and hydrogen-carbonate media. Both media were successfully used for the recuperation of uranium (VI) from very dilute solutions. Equilibrium constant of the exchange [UO 2 (CO 3 ) 3 4+ ] S + 2 [CO 3 2- ] R ↔ [UO 2 (CO 3 ) 3 4- ] R + 2[CO 3 2- ] S is determined for carbonate concentration range 0.1 M to 0.6 M from partition curves. A markedly increase in the relative fixation of uranium results with: - increasing free carbonate concentration of the solution, - decreasing uranium concentration. A study in the same conditions of the fixation of molybdenum has made it possible to separate the latter from uranium by elution, the carbonate concentration being molar. It is suggested a possibility of separation on a larger scale, based upon molybdenum displacement by uranium in hydrogen-carbonate medium. (author) [fr

  10. Interactions between poly(acrylic acid) and sodium dodecyl sulfate: isothermal titration calorimetric and surfactant ion-selective electrode studies.

    Science.gov (United States)

    Wang, C; Tam, K C

    2005-03-24

    Interaction between a monodispersed poly(acrylic acid) (PAA) (M(W) = 5670 g/mol, M(w)/M(n) = 1.02) with sodium dodecyl sulfate (SDS) was investigated using isothermal titration calorimetry (ITC), ion-selective electrode (ISE), and dynamic light scattering measurements. Contrary to previous studies, we report for the first time evidence of interaction between SDS and PAA when the degree of neutralization (alpha) of PAA is lower than 0.2. Hydrocarbon chains of SDS cooperatively bind to apolar segments of PAA driven by hydrophobic interaction. The interaction is both enthalpy and entropy favored (deltaH is negative but deltaS is positive). In 0.05 wt % PAA solution, the SDS concentration corresponding to the onset of binding (i.e., CAC) is approximately 2.4 mM and the saturation concentration (i.e., C(S)) is approximately 13.3 mM when alpha = 0. When PAA was neutralized and ionized, the binding was hindered by the enhanced electrostatic repulsion between negatively charged SDS and PAA chains and improved solubility of the polymer. With increasing alpha to 0.2, CAC increases to approximately 6.2 mM, C(S) drops to 8.6 mM, and the interaction is significantly weakened where the amount of bound SDS on PAA is reduced considerably. The values of CAC and C(S) derived from different techniques are in good agreement. The binding results in the formation of mixed micelles on apolar PAA coils, which then expands and dissociates into single PAA chains. The majority of unneutralized PAA molecules exist as single polymer chains stabilized by bound SDS micelles in solution after the saturation concentration.

  11. Effectiveness of a management program for outpatient clinic or remote titration of beta-blockers in CRT patients: The RESTORE study.

    Science.gov (United States)

    D'Onofrio, Antonio; Palmisano, Pietro; Rapacciuolo, Antonio; Ammendola, Ernesto; Calò, Leonardo; Ruocco, Antonio; Bianchi, Valter; Maresca, Fabio; Del Giorno, Giuseppe; Martino, Annamaria; Mauro, Ciro; Campari, Monica; Valsecchi, Sergio; Accogli, Michele

    2017-06-01

    Many patients fail to receive β-blockers before cardiac resynchronization therapy defibrillator (CRT-D) implantation, or receive them at a suboptimal dose, and require optimization after implantation. We assessed the effectiveness of a structured program for β-blocker titration in CRT-D patients followed up by means of conventional in-clinic visits or remote monitoring. 130 patients undergoing CRT implantation and treated according to the standard practice of the centers were included as a control group. A second group of 124 CRT-D candidates (Study Group) underwent up-titration visits every 2weeks after implantation (target dose: 10mg/day of bisoprolol or 50mg/day of carvedilol). In the Study Group, remote monitoring was undertaken in 66 patients, who received additional equipment for daily transmission of weight and blood pressure data, and scheduled titration telephone calls. In the Control Group, the maximal dose of β-blockers was being administered to 12 (9%) patients on implantation and 21 (16%) on 6-month follow-up examination (p>0.05). In the Study Group, 25 (20%) patients were receiving the maximal dose of β-blockers on implantation and 72 (58%) on follow-up examination (ptitration (versus 38% of patients followed up conventionally, ptitration increased the number of patients reaching the target dose and improved the response to the therapy. The use of remote monitoring and daily transfer of weight and blood pressure data facilitated β-blocker titration. URL: http://clinicaltrials.gov/ Identifier: NCT02173028. Copyright © 2017. Published by Elsevier B.V.

  12. Filtrates & Residues: Olfactory Titration.

    Science.gov (United States)

    Wood, John T.; Eddy, Roberta M.

    1996-01-01

    Presents an experiment that uses a unique acid-base indicator--the odor of raw onion--to indicate the end point of the titration of sodium hydroxide with hydrochloric acid. Allows the student to detect the completion of the neutralization reaction by olfaction rather than sight. (JRH)

  13. ''Titration'' polymerization of monovinylacetylene

    NARCIS (Netherlands)

    Mavinkurve, A; Visser, S; vandenBroek, W; Pennings, AJ

    1996-01-01

    A polymer consisting of a saturated carbon backbone with pendent acetylenic groups was prepared from monovinylacetylene. A titration was performed between the monomer and tertiary butyllithium, its lithiating agent. The charge transfer complex formed between the solvent THF and the tertiary

  14. A nonaqueous potentiometric titration study of the dissociation of t-butyl methacrylate-methacrylic acid copolymers.

    Science.gov (United States)

    Nakatani, Kiyoharu; Yamashita, Jun; Sekine, Tomomi; Toriumi, Minoru; Itani, Toshiro

    2003-05-01

    The dissociation of t-butyl methacrylate-methacrylic acid copolymers in dimethyl sulfoxide was analyzed by a nonaqueous potentiometric titration technique. The negative logarithm of the dissociation constant of the monomer unit of a methacrylic acid (MAA) monotonously increased with the increasing degree of dissociation corresponding to the titrant/MAA amount ratio, and was highly influenced by the copolymerization ratio. The results are discussed in terms of the suppression of the dissociation of MAA by a neighboring charged methacrylate anion unit.

  15. Axitinib dose titration: analyses of exposure, blood pressure and clinical response from a randomized phase II study in metastatic renal cell carcinoma.

    Science.gov (United States)

    Rini, B I; Melichar, B; Fishman, M N; Oya, M; Pithavala, Y K; Chen, Y; Bair, A H; Grünwald, V

    2015-07-01

    In a randomized, double-blind phase II trial in patients with metastatic renal cell carcinoma (mRCC), axitinib versus placebo titration yielded a significantly higher objective response rate. We evaluated pharmacokinetic and blood pressure (BP) data from this study to elucidate relationships among axitinib exposure, BP change, and efficacy. Patients received axitinib 5 mg twice daily during a lead-in period. Patients who met dose-titration criteria were randomized 1:1 to stepwise dose increases with axitinib or placebo. Patients ineligible for randomization continued without dose increases. Serial 6-h and sparse pharmacokinetic sampling were carried out; BP was measured at clinic visits and at home in all patients, and by 24-h ambulatory BP monitoring (ABPM) in a subset of patients. Area under the plasma concentration-time curve from 0 to 24 h throughout the course of treatment (AUCstudy) was higher in patients with complete or partial responses than those with stable or progressive disease in the axitinib-titration arm, but comparable between these groups in the placebo-titration and nonrandomized arms. In the overall population, AUCstudy and efficacy outcomes were not strongly correlated. Mean BP across the population was similar when measured in clinic, at home, or by 24-h ABPM. Weak correlations were observed between axitinib steady-state exposure and diastolic BP. When grouped by change in diastolic BP from baseline, patients in the ≥10 and ≥15 mmHg groups had longer progression-free survival. Optimal axitinib exposure may differ among patients with mRCC. Pharmacokinetic or BP measurements cannot be used exclusively to guide axitinib dosing. Individualization of treatment with vascular endothelial growth factor receptor tyrosine kinase inhibitors, including axitinib, is thus more complex than anticipated and cannot be limited to a single clinical factor. © The Author 2015. Published by Oxford University Press on behalf of the European Society for Medical

  16. Microcalorimetric and potentiometric titration studies on the adsorption of copper by extracellular polymeric substances (EPS), minerals and their composites.

    Science.gov (United States)

    Fang, Linchuan; Huang, Qiaoyun; Wei, Xing; Liang, Wei; Rong, Xinming; Chen, Wenli; Cai, Peng

    2010-08-01

    Equilibrium adsorption experiments, isothermal titration calorimetry and potentiometric titration techniques were employed to investigate the adsorption of Cu(II) by extracellular polymeric substances (EPS) extracted from Pseudomonas putida X4, minerals (montmorillonite and goethite) and their composites. Compared with predicted values of Cu(II) adsorption on composites, the measured values of Cu(II) on EPS-montmorillonite composite increased, however, those on EPS-goethite composite decreased. Potentiometric titration results also showed that more surface sites were observed on EPS-montmorillonite composite and less reactive sites were found on EPS-goethite composite. The adsorption of Cu(II) on EPS molecules and their composites with minerals was an endothermic reaction, while that on minerals was exothermic. The positive values of enthalpy change (Delta H) and entropy change (DeltaS) for Cu(II) adsorption on EPS and mineral-EPS composites indicated that Cu(II) mainly interacts with carboxyl and phosphoryl groups as inner-sphere complexes on EPS molecules and their composites with minerals. (c) 2010 Elsevier Ltd. All rights reserved.

  17. A study on the alkalimetric titration with gran plot in noncomplexing media for the determination of free acid in spent fuel solutions

    International Nuclear Information System (INIS)

    Suh, Moo Yul; Lee, Chang Heon; Sohn, Se Chul; Kim, Jung Suk; Kim, Won Ho; Eom, Tae Yoon

    1999-01-01

    Based on the study of hydrolysis behaviour of U(VI) ion and major fission product metal ions such as Cs(I), Ce(III), Nd(III), Mo(VI), Ru(II), and Zr(VI) in the titration media, the performance of noncomplexing-alkalimetric titration method for the determination of free acid in the presence of these metal ions was investigated and its results were compared to those from the complexing methods. The free acidities could be determined as low as 0.05 meq in uranium solutions in which the molar ratio of U(VI)/H + was less than 5, when the end-point of titration was estimated by Gran plot. The biases in the determinations were less than ±1% and about +3% respectively for 0.4 meq and 0.05 meq of free acid at the U(VI)/H + molar ratio of up to 5. Applicability of this method to the determination of free acid in spent fuel solutions was confirmed by the analysis of nitric acid content in simulated spent fuel solutions and in a real spent fuel solution

  18. Quadriceps force and anterior tibial force occur obviously later than vertical ground reaction force: a simulation study

    OpenAIRE

    Ueno, Ryo; Ishida, Tomoya; Yamanaka, Masanori; Taniguchi, Shohei; Ikuta, Ryohei; Samukawa, Mina; Saito, Hiroshi; Tohyama, Harukazu

    2017-01-01

    Background: Although it is well known that quadriceps force generates anterior tibial force, it has been unclear whether quadriceps force causes great anterior tibial force during the early phase of a landing task. The purpose of the present study was to examine whether the quadriceps force induced great anterior tibial force during the early phase of a landing task. Methods: Fourteen young, healthy, female subjects performed a single-leg landing task. Muscle force and anterior tibial force w...

  19. Is automatic CPAP titration as effective as manual CPAP titration in OSAHS patients? A meta-analysis.

    Science.gov (United States)

    Gao, Weijie; Jin, Yinghui; Wang, Yan; Sun, Mei; Chen, Baoyuan; Zhou, Ning; Deng, Yuan

    2012-06-01

    It is costly and time-consuming to conduct the standard manual titration to identify an effective pressure before continuous positive airway pressure (CPAP) treatment for obstructive sleep apnea (OSA) patients. Automatic titration is cheaper and more easily available than manual titration. The purpose of this systematic review was to evaluate the effect of automatic titration in identifying a pressure and on the improvement of apnea/hyponea index (AHI) and somnolence, the change of sleep quality, and the acceptance and compliance of CPAP treatment, compared with the manual titration. A systematic search was made of the PubMed, EMBASE, Cochrane Library, SCI, China Academic Journals Full-text Databases, Chinese Biomedical Literature Database, Chinese Scientific Journals Databases and Chinese Medical Association Journals. Randomized controlled trials comparing automatic titration and manual titration were reviewed. Studies were pooled to yield odds ratios (OR) or mean differences (MD) with 95% confidence intervals (CI). Ten trials involving 849 patients met the inclusion criteria. It is hard to identify a trend in the pressures determined by either automatic or manual titration. Automatic titration can improve the AHI (MD = 0.03/h, 95% CI = -4.48 to 4.53) and Epworth sleepiness scale (SMD = -0.02, 95% CI = -0.34 to 0.31,) as effectively as the manual titration. There is no difference between sleep architecture under automatic titration or manual titration. The acceptance of CPAP treatment (OR = 0.96, 95% CI = 0.60 to 1.55) and the compliance with treatment (MD = -0.04, 95% CI = -0.17 to 0.10) after automatic titration is not different from manual titration. Automatic titration is as effective as standard manual titration in improving AHI, somnolence while maintaining sleep quality similar to the standard method. In addition, automatic titration has the same effect on the acceptance and compliance of CPAP treatment as manual titration. With the potential advantage

  20. Titration Curves: Fact and Fiction.

    Science.gov (United States)

    Chamberlain, John

    1997-01-01

    Discusses ways in which datalogging equipment can enable titration curves to be measured accurately and how computing power can be used to predict the shape of curves. Highlights include sources of error, use of spreadsheets to generate titration curves, titration of a weak acid with a strong alkali, dibasic acids, weak acid and weak base, and…

  1. Individualized toxicity-titrated 6-mercaptopurine increments during high-dose methotrexate consolidation treatment of lower risk childhood acute lymphoblastic leukaemia. A Nordic Society of Paediatric Haematology and Oncology (NOPHO) pilot study

    DEFF Research Database (Denmark)

    Frandsen, Thomas L; Abrahamsson, Jonas; Lausen, Birgitte

    2011-01-01

    This study explored the feasibility and toxicity of individualized toxicity-titrated 6-mercaptopurine (6MP) dose increments during post-remission treatment with High-dose methotrexate (HDM) (5000 mg/m(2), ×3) in 38 patients with Childhood (ALL). Patients were increased in steps of 25 mg 6MP/m(2...... the remaining patients (P = 0·03). This study shows individualized toxicity-titrated 6MP dosing during consolidation is feasible without increased risk of toxicity....

  2. The Effect of Metal Concentration on the Parameters Derived from Complexometric Titrations of Trace Elements in Seawater—A Model Study

    Directory of Open Access Journals (Sweden)

    Martha Gledhill

    2017-08-01

    Full Text Available In this study we examine the impact of dissolved metal concentrations on the parameters that are commonly determined from complexometric titrations in seawater. We use the non-ideal competitive adsorption (NICA model within the framework of the chemical speciation program visual MINTEQ with iron as a model metal. We demonstrate that dissolved iron concentrations effect the determined parameters for a heterogeneous binding site distribution with a fixed concentration of dissolved organic carbon. The commonly used terms “ligand concentration” and “binding constant” are therefore dependent on metal concentration, so we adopt the terminology suggested by Town and Filella (2000 and use the terms ligand quotient and stability quotient here. The systematic increase in the ligand quotient with dissolved iron concentration likely contributes toward the trend of increasing ligand quotient with dissolved iron concentration observed in field studies, and makes it hard to assign an objective meaning to the parameter. We suggest that calculation of the side reaction coefficient, a parameter that describes the probability that any added metal will be complexed, could be less prone to bias and misinterpretation than calculation of conditional stability and ligand quotients. We explore the impact of experimental design on side reaction coefficients by applying different detection windows, and multiwindow and reverse titration approaches. We identify the method that results in the best estimates of side reaction coefficients over a range of iron concentrations between 0.1 and 1.5 nmol L−1. We find that single window titrations can only reliably estimate side reaction coefficients over a limited range of iron concentrations. Multiwindow titrations provided estimates of side reaction coefficients within the 99% confidence interval of the values calculated directly from the NICA model at all iron concentrations examined here. We recommend that future

  3. A 24-Week, Randomized, Controlled Study to Evaluate the Tolerability, Safety and Efficacy of 2 Different Titration Schemes of the Rivastigmine Patch in Japanese Patients with Mild to Moderate Alzheimer's Disease

    Directory of Open Access Journals (Sweden)

    Yu Nakamura

    2015-09-01

    Full Text Available Aim: To investigate whether 1-step titration of the rivastigmine patch (initiated at 5 cm2 and titrated to 10 cm2 after 4 weeks is well tolerated in Japanese patients with Alzheimer's disease (AD as compared to 3-step titration (initiated at 2.5 cm2 and titrated by 2.5 cm2 every 4 weeks to 10 cm2. Methods: A 24-week, multicenter, randomized, double-blind study was conducted in Japan between July 2012 and May 2014. Patients with mild to moderate AD aged 50-85 years were randomized 1:1 to 1-step or 3-step titration of the rivastigmine once-daily patch. The primary endpoint was the proportion of patients with adverse events leading to discontinuation. Results: Of 216 patients randomized, 215 (1-step, n = 107; 3-step, n = 108 were included in the safety analysis. The primary endpoint outcome was 15.0% in the 1-step group and 18.5% in the 3-step group. The observed treatment difference was −3.6% (95% confidence interval: −17.0, 9.6, falling within the prespecified acceptance range. Conclusion: The tolerability of two different titration schemes was similar in Japanese patients with AD.

  4. Raman spectral titration method: an informative technique for studying the complexation of uranyl with uranyl(vi)-DPA/oxalate systems as examples.

    Science.gov (United States)

    Liu, Qian; Zhang, Qianci; Yang, Suliang; Zhu, Haiqiao; Liu, Quanwei; Tian, Guoxin

    2017-10-10

    The Raman band at about 870 cm -1 originating from the symmetric stretch vibration (ν 1 ) of uranyl, UO 2 2+ , has proven to be very informative for investigating the complexation of uranyl using perchlorate or nitrate of known concentration as internal standards. The concentration of uranyl can be conveniently calculated by using the ratio of the directly read band intensities of uranyl and the added reference, ClO 4 - , with a factor of 1.72. While with NO 3 - of concentration lower than 1.8 M as the reference, a factor of 0.85 should be used. Furthermore, with added internal standards, the linear relationship between the Raman intensity and the concentration of the corresponding species is illustrated by the spectral titration of U(vi) with a very strong ligand, dipicolinic acid (DPA); and the application of a spectral titration method with Raman spectroscopy in studying the complexation of uranyl is demonstrated by the titration of U(vi) with oxalate. The stepwise changes in the Raman shift of 18, 17, and 6 cm -1 , corresponding to the three oxalate anions successively bonding to UO 2 2+ , imply that the coordination modes are different. In the 1 : 1 and 1 : 2 ratios of metal to ligand complexes, the oxalate anions bond to the uranyl ion in side-on bidentate mode, but in the 1 : 3 complex the third oxalate bonds in head-on mode, which is much weaker than the first two.

  5. Open-Label Randomized Trial of Titrated Disease Management for Patients with Hypertension: Study Design and Baseline Sample Characteristics

    Science.gov (United States)

    Jackson, George L.; Weinberger, Morris; Kirshner, Miriam A.; Stechuchak, Karen M.; Melnyk, Stephanie D.; Bosworth, Hayden B.; Coffman, Cynthia J.; Neelon, Brian; Van Houtven, Courtney; Gentry, Pamela W.; Morris, Isis J.; Rose, Cynthia M.; Taylor, Jennifer P.; May, Carrie L.; Han, Byungjoo; Wainwright, Christi; Alkon, Aviel; Powell, Lesa; Edelman, David

    2016-01-01

    Despite the availability of efficacious treatments, only half of patients with hypertension achieve adequate blood pressure (BP) control. This paper describes the protocol and baseline subject characteristics of a 2-arm, 18-month randomized clinical trial of titrated disease management (TDM) for patients with pharmaceutically-treated hypertension for whom systolic blood pressure (SBP) is not controlled (≥140mmHg for non-diabetic or ≥130mmHg for diabetic patients). The trial is being conducted among patients of four clinic locations associated with a Veterans Affairs Medical Center. An intervention arm has a TDM strategy in which patients' hypertension control at baseline, 6, and 12 months determines the resource intensity of disease management. Intensity levels include: a low-intensity strategy utilizing a licensed practical nurse to provide bi-monthly, non-tailored behavioral support calls to patients whose SBP comes under control; medium-intensity strategy utilizing a registered nurse to provide monthly tailored behavioral support telephone calls plus home BP monitoring; and high-intensity strategy utilizing a pharmacist to provide monthly tailored behavioral support telephone calls, home BP monitoring, and pharmacist-directed medication management. Control arm patients receive the low-intensity strategy regardless of BP control. The primary outcome is SBP. There are 385 randomized (192 intervention; 193 control) veterans that are predominately older (mean age 63.5 years) men (92.5%). 61.8% are African American, and the mean baseline SBP for all subjects is 143.6mmHg. This trial will determine if a disease management program that is titrated by matching the intensity of resources to patients' BP control leads to superior outcomes compared to a low-intensity management strategy. PMID:27417982

  6. Potentiometric titration with polarized electrodes

    International Nuclear Information System (INIS)

    Chikryzova, E.G.

    1977-01-01

    Based on the analysis of the works carried out during 1911-75 consideration is given to the present state of the method of potentiometric titration with polarized electrodes. The material is generalized in the tabular form indicating the elments of interest, titration conditions and the objects to be analyzed. The list and classification of the potentiometric titration methods intended for determining organic and inorganic substances are presented

  7. A critical study of the alkalimetric titration of mannitoboric acid complex in relation to the determination of boron in glass and related materials

    International Nuclear Information System (INIS)

    Sinha, B.C.; Dasgupta, S.

    1976-01-01

    The effect of mannitol concentration on the slope of ΔpH/Δv at the equivalence point of neutralisation of mannitoboric acid has been studied. The slope is observed to be dependent on mannitol concentration and it increases with increasing reagent concentration. The minimum pH at which titration of mannitoboric acid complex is possible without any significant error has been found to be 6.4 with a mannitol concentration of at least 15 g/50 ml of solution although the stoichiometric equivalence pH is 9.0. Based on the result of the study, a simple and accurate method has been worked out for the determination of B 2 0 3 up to 141 mg/50 ml in glass and related materials. The titration of mannitoboric acid complex is carried out at the minimum equivalence pH of 6.4 to minimise precipitation of hydroxides and phosphates of certain cations. The interference due to various elements such as Al, Fe, Zr, Pb and Zn when present are eliminated by complexing them with EDTA. Fluorine above 40 mg/50 ml interferes with the determination. (author)

  8. A study of pH-dependent photodegradation of amiloride by a multivariate curve resolution approach to combined kinetic and acid-base titration UV data.

    Science.gov (United States)

    De Luca, Michele; Ioele, Giuseppina; Mas, Sílvia; Tauler, Romà; Ragno, Gaetano

    2012-11-21

    Amiloride photostability at different pH values was studied in depth by applying Multivariate Curve Resolution Alternating Least Squares (MCR-ALS) to the UV spectrophotometric data from drug solutions exposed to stressing irradiation. Resolution of all degradation photoproducts was possible by simultaneous spectrophotometric analysis of kinetic photodegradation and acid-base titration experiments. Amiloride photodegradation showed to be strongly dependent on pH. Two hard modelling constraints were sequentially used in MCR-ALS for the unambiguous resolution of all the species involved in the photodegradation process. An amiloride acid-base system was defined by using the equilibrium constraint, and the photodegradation pathway was modelled taking into account the kinetic constraint. The simultaneous analysis of photodegradation and titration experiments revealed the presence of eight different species, which were differently distributed according to pH and time. Concentration profiles of all the species as well as their pure spectra were resolved and kinetic rate constants were estimated. The values of rate constants changed with pH and under alkaline conditions the degradation pathway and photoproducts also changed. These results were compared to those obtained by LC-MS analysis from drug photodegradation experiments. MS analysis allowed the identification of up to five species and showed the simultaneous presence of more than one acid-base equilibrium.

  9. Surface forces studied with colloidal probe atomic force microscopy

    NARCIS (Netherlands)

    Giesbers, M.

    2001-01-01

    Forces between surfaces are a determining factor for the performance of natural as well as synthetic colloidal systems, and play a crucial role in industrial production processes. Measuring these forces is a scientific and experimental challenge and over the years several techniques have

  10. Experimental studies of the magnetized friction force

    International Nuclear Information System (INIS)

    Fedotov, A. V.; Litvinenko, V. N.; Gaalnander, B.; Lofnes, T.; Ziemann, V.; Sidorin, A.; Smirnov, A.

    2006-01-01

    High-energy electron cooling, presently considered as an essential tool for several applications in high-energy and nuclear physics, requires an accurate description of the friction force which ions experience by passing through an electron beam. Present low-energy electron coolers can be used for a detailed study of the friction force. In addition, parameters of a low-energy cooler can be chosen in a manner to reproduce regimes expected in future high-energy operation. Here, we report a set of dedicated experiments in CELSIUS aimed at a detailed study of the magnetized friction force. Some results of the accurate comparison of experimental data with the friction force formulas are presented

  11. Up-titration of allopurinol in patients with gout.

    Science.gov (United States)

    Jennings, Claudine G; Mackenzie, Isla S; Flynn, Rob; Ford, Ian; Nuki, George; De Caterina, Raffaele; Riches, Philip L; Ralston, Stuart H; MacDonald, Thomas M

    2014-08-01

    European League against Rheumatism (EULAR) gout management guidelines recommend achieving a target urate level titration in achieving the EULAR target levels. The Febuxostat versus Allopurinol Streamlined Trial (FAST) is an ongoing multi-centre study comparing the cardiovascular safety of febuxostat and allopurinol (target recruitment: 5706 patients). Recruited patients were already taking allopurinol and the protocol required up-titration of daily allopurinol dose, in 100 mg increments, to achieve the EULAR urate target level prior to randomisation. We reviewed pre-randomisation data from the first 400 recruited and subsequently randomised FAST patients. Of 400 patients, 144 (36%) had urate levels ≥357 µmol/L at screening and required allopurinol up-titration. Higher urate levels were significantly associated with lower allopurinol dose, male sex, increased BMI, increased alcohol intake and diuretic use. Mean fall in urate levels after a single 100-mg dose increase was 71 µmol/L. The number of up-titrations required ranged from one to five (median = 1) with 65% of patients controlled after one 100-mg up-titration. Overall, 97% of up-titrated patients achieved target urate levels with median final allopurinol dose of 300 mg daily. Side effects and complications of up-titration were minimal. Overall, 36% of FAST patients were not at target urate levels and required up-titration. Allopurinol up-titration was effective in achieving urate target levels and was generally well tolerated by patients. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Microculture virus titration--a simple colourimetric assay for influenza virus titration.

    Science.gov (United States)

    Levi, R; Beeor-Tzahar, T; Arnon, R

    1995-03-01

    Influenza antigens can be detected by several well established methods. However, when it is important to determine the titre of infective virions, a bioassay should be employed. The standard and the most widely used tests for influenza infectivity are titration carried out in embryonated hen eggs, or the plaque assay employing tissue culture techniques. A simple colourimetric assay for influenza virus detection and titration is described. Samples of allantoic fluid or mice lung homogenates were used to infect MDCK cultures in microplate wells. After an incubation period, the tetrazolium (MTT) colourimetric assay was used to determine cell viability, and when compared to untreated culture control enabled the detection and titration of several influenza strains. When samples were assayed simultaneously in embryonated eggs and by the MCVT method, good correlation in determined titres was obtained. The availability of an additional method for influenza titration allows more flexibility in the choice of titration method according to the specific needs of the study. Furthermore, this method lends itself to full automatization. Similar procedures should also be applicable to titration of other cytopathic viruses.

  13. Analysis of the interactions between human serum albumin/amphiphilic penicillin in different aqueous media: an isothermal titration calorimetry and dynamic light scattering study

    International Nuclear Information System (INIS)

    Barbosa, Silvia; Taboada, Pablo; Mosquera, Victor

    2005-01-01

    The complexation process of the amphiphilic penicillins sodium cloxacillin and sodium dicloxacillin with the protein human serum albumin (HSA) in aqueous buffered solutions of pH 4.5 and 7.4 at 25 o C was investigated through isothermal titration calorimetry (ITC) and dynamic light scattering. ITC experiments were carried out in the very dilute regime and showed that although hydrophobic interactions are the leading forces for complexation, electrostatic interactions also play an important role. The possibility of the formation of hydrogen bonds is also deduced from experimental data. The thermodynamic quantities of the binding mechanism, i.e, the enthalpy, ΔHITCi, entropy, ΔSITCi, Gibbs energy, ΔGITCi, binding constant, KITCi and the number of binding sites, n i , were obtained. The binding was saturable and is characterised by Langmuir adsorption isotherms. From ITC data and following a theoretical model, the number of bound and free penicillin molecules was calculated. From Scatchard plots, KITCi and n i were obtained and compared with those from ITC data. The interaction potential between the HSA-penicillin complexes and their stability were determined at pH 7.4 from the dependence of the diffusion coefficients on protein concentration by application of the DLVO colloidal stability theory. The results indicate decreasing stability of the colloidal dispersion of the drug-protein complexes with increase in the concentration of added drug

  14. Differential Binding Models for Direct and Reverse Isothermal Titration Calorimetry.

    Science.gov (United States)

    Herrera, Isaac; Winnik, Mitchell A

    2016-03-10

    Isothermal titration calorimetry (ITC) is a technique to measure the stoichiometry and thermodynamics from binding experiments. Identifying an appropriate mathematical model to evaluate titration curves of receptors with multiple sites is challenging, particularly when the stoichiometry or binding mechanism is not available. In a recent theoretical study, we presented a differential binding model (DBM) to study calorimetry titrations independently of the interaction among the binding sites (Herrera, I.; Winnik, M. A. J. Phys. Chem. B 2013, 117, 8659-8672). Here, we build upon our DBM and show its practical application to evaluate calorimetry titrations of receptors with multiple sites independently of the titration direction. Specifically, we present a set of ordinary differential equations (ODEs) with the general form d[S]/dV that can be integrated numerically to calculate the equilibrium concentrations of free and bound species S at every injection step and, subsequently, to evaluate the volume-normalized heat signal (δQ(V) = δq/dV) of direct and reverse calorimetry titrations. Additionally, we identify factors that influence the shape of the titration curve and can be used to optimize the initial concentrations of titrant and analyte. We demonstrate the flexibility of our updated DBM by applying these differentials and a global regression analysis to direct and reverse calorimetric titrations of gadolinium ions with multidentate ligands of increasing denticity, namely, diglycolic acid (DGA), citric acid (CIT), and nitrilotriacetic acid (NTA), and use statistical tests to validate the stoichiometries for the metal-ligand pairs studied.

  15. Microparticle adhesion studies by atomic force microscopy

    NARCIS (Netherlands)

    Segeren, L.H.G.J.; Siebum, B.; Karssenberg, F.G.; Berg, van den J.W.A.; Vancso, G.J.

    2002-01-01

    Atomic force microscopy (AFM) is one of the most flexible and simple techniques for probing surface interactions. This article reviews AFM studies on particle adhesion. Special attention is paid to the characterization of roughness and its effect on adhesion. This is of importance when comparing the

  16. Students' integration of multiple representations in a titration experiment

    Science.gov (United States)

    Kunze, Nicole M.

    A complete understanding of a chemical concept is dependent upon a student's ability to understand the microscopic or particulate nature of the phenomenon and integrate the microscopic, symbolic, and macroscopic representations of the phenomenon. Acid-base chemistry is a general chemistry topic requiring students to understand the topics of chemical reactions, solutions, and equilibrium presented earlier in the course. In this study, twenty-five student volunteers from a second semester general chemistry course completed two interviews. The first interview was completed prior to any classroom instruction on acids and bases. The second interview took place after classroom instruction, a prelab activity consisting of a titration calculation worksheet, a titration computer simulation, or a microscopic level animation of a titration, and two microcomputer-based laboratory (MBL) titration experiments. During the interviews, participants were asked to define and describe acid-base concepts and in the second interview they also drew the microscopic representations of four stages in an acid-base titration. An analysis of the data showed that participants had integrated the three representations of an acid-base titration to varying degrees. While some participants showed complete understanding of acids, bases, titrations, and solution chemistry, other participants showed several alternative conceptions concerning strong acid and base dissociation, the formation of titration products, and the dissociation of soluble salts. Before instruction, participants' definitions of acid, base, and pH were brief and consisted of descriptive terms. After instruction, the definitions were more scientific and reflected the definitions presented during classroom instruction.

  17. Amperometric, Bipotentiometric, and Coulometric Titration.

    Science.gov (United States)

    Stock, John T.

    1980-01-01

    Discusses recent review articles in various kinds of titration. Also discusses new research in apparatus and methodology, acid-base reactions, precipitation and complexing reactions, oxidation-reduction reactions, and nomenclature. Cites 338 references. (CS)

  18. A randomised controlled trial evaluating IGF1 titration in contrast to current GH dosing strategies in children born small for gestational age: the North European Small-for-Gestational-Age Study.

    Science.gov (United States)

    Jensen, Rikke Beck; Thankamony, Ajay; O'Connell, Susan M; Kirk, Jeremy; Donaldson, Malcolm; Ivarsson, Sten-A; Söder, Olle; Roche, Edna; Hoey, Hilary; Dunger, David B; Juul, Anders

    2014-10-01

    Short children born small for gestational age (SGA) are treated with a GH dose based on body size, but treatment may lead to high levels of IGF1. The objective was to evaluate IGF1 titration of GH dose in contrast to current dosing strategies. In the North European Small-for-Gestational-Age Study (NESGAS), 92 short pre-pubertal children born SGA were randomised after 1 year of high-dose GH treatment (67 μg/kg per day) to three different regimens: high dose (67 μg/kg per day), low dose (35 μg/kg per day) or IGF1 titration. The average dose during the second year of the randomised trial did not differ between the IGF1 titration group (38 μg/kg per day, s.d. 0.019) and the low-dose group (35 μg/kg per day, s.d. 0.002; P=0.46), but there was a wide variation in the IGF1 titration group (range 10-80 μg/kg per day). The IGF1 titration group had significantly lower height gain (0.17 SDS, s.d. 0.18) during the second year of the randomised trial compared with the high-dose group (0.46 SDS, s.d. 0.25), but not significantly lower than the low-dose group (0.23 SDS, s.d. 0.15; P=0.17). The IGF1 titration group had lower IGF1 levels after 2 years of the trial (mean 1.16, s.d. 1.24) compared with both the low-dose (mean 1.76, s.d. 1.48) and the high-dose (mean 2.97, s.d. 1.63) groups. IGF1 titration of GH dose in SGA children proved less effective than current dosing strategies. IGF1 titration resulted in physiological IGF1 levels with a wide range of GH dose and a poorer growth response, which indicates the role of IGF1 resistance and highlights the heterogeneity of short SGA children. © 2014 European Society of Endocrinology.

  19. Large General Purpose Frame for Studying Force Vectors

    Science.gov (United States)

    Heid, Christy; Rampolla, Donald

    2011-01-01

    Many illustrations and problems on the vector nature of forces have weights and forces in a vertical plane. One of the common devices for studying the vector nature of forces is a horizontal "force table," in which forces are produced by weights hanging vertically and transmitted to cords in a horizontal plane. Because some students have…

  20. Refugee and Forced Migration Studies Online

    DEFF Research Database (Denmark)

    Andersson, Vibeke

    developments in communications technologies and the Internet and the proliferation of websites such as the CARFMS – Online Research and Teaching Tool and Practitioners Forum (ORTT & PF) and the Refugee Research Network (RRN), as examples, have contributed to the accessibility of information, knowledge......IASFM 14: Contested Spaces and Cartographic Challenges Kolkata, India, January 6-9, 2013 ABSTRACT for a Roundtable on the topic of Refugee and Forced Migration Studies Online: Harnessing “the Cloud” for Knowledge Generation, Instruction, and Mobilization With the advent of the Internet...... and the proliferation of websites and online instruments on refugee and forced migration studies the nature of research and information gathering, analysis, and dissemination, along with advocacy, has altered fundamentally both in its range, depth and scope. This Roundtable will seek to review how the latest...

  1. Transition of a Text-Based Insulin Titration Program From a Randomized Controlled Trial Into Real-World Settings: Implementation Study

    Science.gov (United States)

    Orzeck-Byrnes, Natasha A; Aidasani, Sneha R; Moloney, Dana N; Nguyen, Lisa H; Park, Agnes; Hu, Lu; Langford, Aisha T; Wang, Binhuan; Sevick, Mary Ann; Rogers, Erin S

    2018-01-01

    Background The Mobile Insulin Titration Intervention (MITI) program helps patients with type 2 diabetes find their correct basal insulin dose without in-person care. Requiring only basic cell phone technology (text messages and phone calls), MITI is highly accessible to patients receiving care in safety-net settings. MITI was shown in a randomized controlled trial (RCT) to be efficacious at a New York City (NYC) safety-net clinic where patients often have challenges coming for in-person care. In 2016, MITI was implemented as usual care at Bellevue Hospital (the site of the original RCT) and at Gouverneur Health (a second NYC safety-net clinic) under 2 different staffing models. Objective This implementation study examined MITI’s transition into real-world settings. To understand MITI’s flexibility, generalizability, and acceptability among patients and providers, we evaluated whether MITI continued to produce positive outcomes in expanded underserved populations, outside of an RCT setting. Methods Patients enrolled in MITI received weekday text messages asking for their fasting blood glucose (FBG) values and a weekly titration call. The goal was for patients to reach their optimal insulin dose (OID), defined either as the dose of once-daily basal insulin required to achieve either an FBG of 80-130 mg/dL (4.4-7.2 mmol/L) or as the reaching of the maximum dose of 50 units. After 12 weeks, if OID was not reached, the patients were asked to return to the clinic for in-person care and titration. MITI program outcomes, clinical outcomes, process outcomes, and patient satisfaction were assessed. Results MITI was successful at both sites, each with a different staffing model. Providers referred 170 patients to the program—129 of whom (75.9%, 129/170) were eligible. Of these, 113 (87.6%, 113/129) enrolled. Moreover, 84.1% (95/113) of patients reached their OID, and they did so in an average of 24 days. Clinical outcomes show that mean FBG levels fell from 209 mg

  2. Effect of exenatide QW or placebo, both added to titrated insulin glargine, in uncontrolled type 2 diabetes: The DURATION-7 randomized study.

    Science.gov (United States)

    Guja, Cristian; Frías, Juan P; Somogyi, Aniko; Jabbour, Serge; Wang, Hui; Hardy, Elise; Rosenstock, Julio

    2018-02-23

    To compare the efficacy and safety of adding the glucagon-like peptide-1 receptor agonist exenatide once weekly (QW) 2 mg or placebo among patients with type 2 diabetes who were inadequately controlled despite titrated insulin glargine (IG) ± metformin. This multicentre, double-blind study (ClinicalTrials.gov identifier: NCT02229383) randomized (1:1) patients with persistent hyperglycaemia after an 8-week titration phase (glycated haemoglobin [HbA1c] 7.0%-10.5% [53-91 mmol/mol]) to exenatide QW or placebo. The primary endpoint was HbA1c change from baseline to week 28. Secondary endpoints included body weight, 2-hour postprandial glucose, and mean daily IG dose. Of 464 randomized patients (mean: age, 58 years; HbA1c, 8.5% [69 mmol/mol]; diabetes duration, 11.3 years), 91% completed 28 weeks. Exenatide QW + IG vs placebo + IG significantly reduced HbA1c (least-squares mean difference, -0.73% [-8.0 mmol/mol]; 95% confidence interval, -0.93%, -0.53% [-10.2, -5.8 mmol/mol]; P < .001; final HbA1c, 7.55% [59 mmol/mol] and 8.24% [67 mmol/mol], respectively); body weight (-1.50 kg; -2.17, -0.84; P < .001); and 2-hour postprandial glucose (-1.52 mmol/L [-27.5 mg/dL]; -2.15, -0.90 [-38.7, -16.2]; P < .001). Significantly more exenatide QW + IG-treated patients vs placebo + IG-treated patients reached HbA1c <7.0% (<53 mmol/mol) (32.5% vs 7.4%; P < .001); daily IG dose increased by 2 and 4 units, respectively. Gastrointestinal and injection-site adverse events were more frequent with exenatide QW + IG (15.1% and 7.8%, respectively) than with placebo + IG (10.8% and 3.0%, respectively); hypoglycaemia incidence was similar between the exenatide QW + IG (29.7%) and placebo + IG (29.0%) groups, with no major hypoglycaemic events. Among patients with inadequate glycaemic control, exenatide QW significantly improved glucose control and decreased body weight, without increased hypoglycaemia or unexpected safety findings.

  3. Potentiometric titrations in anhydrous acetic acid

    International Nuclear Information System (INIS)

    Le Port, L.

    1966-03-01

    The method used for studying anhydrous acetic acid is potentiometry with a glass electrode. We have in this way studied the titration of common inorganic acids (HClO 4 - HBr - H 2 SO 4 - HCl - HNO 3 - H 3 PO 4 ) and of some metallic salts. Furthermore we have shown that complex acids are formed between HCl and some metallic chlorides. An analysis of the titration curves for the inorganic acids against pyridinium chloride has made it possible to calculate a certain number of values for the dissociation pK of these acids and of the corresponding pyridinium salts. The titration of metallic perchlorates constitutes a method of studying the stability of acetates; we have thus been able to draw up a classification for some of these acetates. The metallic chlorides studied fall into two groups according to their behaviour in weak or strong acids. The differences have been explained on the basis of the role played by solvolysis. In the third part we have studied the acidic properties of mixtures of HCl with certain metallic chlorides. This work has demonstrated the existence, in certain cases, of acid complexes of the type (HCl) m MCl n . (author) [fr

  4. TAPIR: a device for automatic titration with incremental weighing of the titration reagent

    International Nuclear Information System (INIS)

    Ganivet, Michel

    TAPIR is a titration device enabling automatic analyses with weighting of the titration reagent. The titration method used can be based on potentiometry, amperometry, color indicator change... The reproducibility is about 3.10 -4 [fr

  5. 1H NMR study of effects of synergistic anion and metal ion binding on pH titration of the histidinyl side-chain residues of the half-molecules of ovotransferrin

    International Nuclear Information System (INIS)

    Woodworth, R.C.; Butcher, N.D.; Brown, S.A.; Brown-Mason, A.

    1987-01-01

    Separation of ovotransferrin into C-terminal (OTf/2C) and N-terminal (OTf/2N) half-molecules has made possible the resolution of all expected histidinyl C(2)H resonances by proton nuclear magnetic resonance at 250 MHz. The chemical shift of many of the resonances decreases with increasing pH, allowing construction of titration curves, whereas a few resonances fail to titrate. On formation of the Ga/sup III/OTf/2(C 2 O 4 ) ternary complexes, two of the low-field C(2)H resonances in each half-molecule fail to titrate. This behavior implicates the imidazole groups giving rise to these resonances as ligands to the bound metal ion. A third C(2)H resonance in each half-molecule undergoes a marked reduction in pK'/sub a/ on formation of the ternary complex. The imidazole group displaying this resonance is implicated in a proton-relay scheme involved in binding the synergistic anion, oxalate, and a water of hydration on the bound metal ion. The titration curves for the various imidazole resonances have been fit to a four-parameter equation involving estimation of the pK'/sub a/, the limiting chemical shift values, and a Hill constant n. Hill constants of 1, which suggests positive cooperativity in the titration of this residue. The basis for this behavior cannot be rationalized at this time. 13 C NMR studies of [zeta- 13 C]Arg-OTf suggest the Arg side chains may not be intimately involved in formation of the ternary complex

  6. Thermodynamic insights into drug-surfactant interactions: Study of the interactions of naporxen, diclofenac sodium, neomycin, and lincomycin with hexadecytrimethylammonium bromide by using isothermal titration calorimetry.

    Science.gov (United States)

    Choudhary, Sinjan; Talele, Paurnima; Kishore, Nand

    2015-08-01

    The success of drug delivery depends on the efficiency of the route of administration, which in turn relies on properties of the drug and its transport vehicle. A quantitative knowledge of association of drugs with transport vehicles is lacking when the latter are in the category of self assembled structures. The work reported in this manuscript addresses the mechanism of partitioning of naproxen, diclofenac sodium, neomycin and lincomycin in the micelles of hexadecytrimethylammonium bromide and that is quantitatively based on the measurement of thermodynamic parameters of interactions by using isothermal titration calorimetry. The addressed mechanism of partitioning is based on the identification of the type of interactions of these drugs with the surfactant micelles and monomers, along with the effect of the former on the micellization properties of the surfactant. The conclusions are based on the interpretation of the values of partitioning constant, standard molar enthalpy change, standard molar entropy change and the stoichiometry of the interaction. The results of this study have implications for deriving guidelines for the target oriented synthesis of new drugs that are to be used for effective delivery via micellar media. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Effect of pH on the complexation of kaempferol-4'-glucoside with three β-cyclodextrin derivatives: isothermal titration calorimetry and spectroscopy study.

    Science.gov (United States)

    Zheng, Yan; Dong, Li-Na; Liu, Min; Chen, Aiju; Feng, Shangcai; Wang, Bingquan; Sun, Dezhi

    2014-01-08

    The utilization of kaempferol and its glycosides in food and pharmaceutical industries could be improved by the formation of inclusion complexes with cyclodextrins at different pH. This study explores the complexation of kaempferol-4'-glucoside with sulfobutyl ether-β-cyclodextrin (SBE-β-CD), hydroxypropyl-β-cyclodextrin (HP-β-CD), and methylated-β-cyclodextrin (M-β-CD) in phosphate buffer solutions of different pH using isothermal titration calorimetry, UV-vis absorption and proton nuclear magnetic resonance spectroscopy at 298.2 K. Experimental results showed that kaempferol-4'-glucoside binds with the three β- cyclodextrins in the same 1:1 stoichiometry. The rank order of stability constants is SBE-β-CD > HP-β-CD > M-β-CD at the same pH level and pH 6.0 > pH 7.4 > pH 9.0 for the same cyclodextrin. The binding of kaempferol-4'-glucoside with the three β-cyclodextrin derivatives is synergistically driven by enthalpy and entropy at pH 6.0 and enthalpy-driven at pH 7.4 and 9.0. The possible inclusion mode was that in the cavity of β-CD is included the planar benzopyranic-4-one part of the kaempferol-4'-glucoside.

  8. Comparison study Of H2O determination in UO2 powder by using MEA (Moisture Evaluation Analysis) and KFT (Karl Fischer Titration)

    International Nuclear Information System (INIS)

    Farida; Yudhi, N.; Lilis, W.; Putro, P.K.

    2000-01-01

    To find out an analytical method to determine H 2 O content in UO 2 powder as fuel elements of power reactors which is simple, economical, precise, and accurate, it is necessary to do comparison study of H 2 O content determination using MEA method which is based on electrolysis process with two helically wound electrodes which contains P 2 O 5 that has function to absorb water steam. The platinum electrodes have a 67 Volt potential on them. The quantity of charge required to electrolyse 0.1 μgr of H 2 O is a constant which is the basic of the electronic measurement. In KFT method is based on volumetric titration using the one component reagent hydronol composite contain all reactants i.e. iodine, sulfur dioxide and imidazole as the base, dissolved in a suitable alcohol. The t- (student) test show that there is no different result significantly between those method. The H 2 O contain obtained is 0.956±0.0095 %, for MEA method and 0.953±0.023 % for KFT method. (author)

  9. Theoretical study of the acid-base properties of the montmorillonite/electrolyte interface: influence of the surface heterogeneity and ionic strength on the potentiometric titration curves.

    Science.gov (United States)

    Zarzycki, Piotr; Thomas, Fabien

    2006-10-15

    The parallel shape of the potentiometric titration curves for montmorillonite suspension is explained using the surface complexation model and taking into account the surface heterogeneity. The homogeneous models give accurate predictions only if they assume unphysically large values of the equilibrium constants for the exchange process occurring on the basal plane. However, the assumption that the basal plane is energetically heterogeneous allows to fit the experimental data (reported by Avena and De Pauli [M. Avena, C.P. De Pauli, J. Colloid Interface Sci. 202 (1998) 195-204]) for reasonable values of exchange equilibrium constant equal to 1.26 (suggested by Fletcher and Sposito [P. Fletcher, G. Sposito, Clay Miner. 24 (1989) 375-391]). Moreover, we observed the typical behavior of point of zero net proton charge (pznpc) as a function of logarithm of the electrolyte concentration (log[C]). We showed that the slope of the linear dependence, pznpc=f(log[C]), is proportional to the number of isomorphic substitutions in the crystal phase, which was also observed in the experimental studies.

  10. Kinetic Titration Series with Biolayer Interferometry

    Science.gov (United States)

    Frenzel, Daniel; Willbold, Dieter

    2014-01-01

    Biolayer interferometry is a method to analyze protein interactions in real-time. In this study, we illustrate the usefulness to quantitatively analyze high affinity protein ligand interactions employing a kinetic titration series for characterizing the interactions between two pairs of interaction patterns, in particular immunoglobulin G and protein G B1 as well as scFv IC16 and amyloid beta (1–42). Kinetic titration series are commonly used in surface plasmon resonance and involve sequential injections of analyte over a desired concentration range on a single ligand coated sensor chip without waiting for complete dissociation between the injections. We show that applying this method to biolayer interferometry is straightforward and i) circumvents problems in data evaluation caused by unavoidable sensor differences, ii) saves resources and iii) increases throughput if screening a multitude of different analyte/ligand combinations. PMID:25229647

  11. Digital movie-based on automatic titrations.

    Science.gov (United States)

    Lima, Ricardo Alexandre C; Almeida, Luciano F; Lyra, Wellington S; Siqueira, Lucas A; Gaião, Edvaldo N; Paiva Junior, Sérgio S L; Lima, Rafaela L F C

    2016-01-15

    This study proposes the use of digital movies (DMs) in a flow-batch analyzer (FBA) to perform automatic, fast and accurate titrations. The term used for this process is "Digital movie-based on automatic titrations" (DMB-AT). A webcam records the DM during the addition of the titrant to the mixing chamber (MC). While the DM is recorded, it is decompiled into frames ordered sequentially at a constant rate of 26 frames per second (FPS). The first frame is used as a reference to define the region of interest (ROI) of 28×13pixels and the R, G and B values, which are used to calculate the Hue (H) values for each frame. The Pearson's correlation coefficient (r) is calculated between the H values of the initial frame and each subsequent frame. The titration curves are plotted in real time using the r values and the opening time of the titrant valve. The end point is estimated by the second derivative method. A software written in C language manages all analytical steps and data treatment in real time. The feasibility of the method was attested by application in acid/base test samples and edible oils. Results were compared with classical titration and did not present statistically significant differences when the paired t-test at the 95% confidence level was applied. The proposed method is able to process about 117-128 samples per hour for the test and edible oil samples, respectively, and its precision was confirmed by overall relative standard deviation (RSD) values, always less than 1.0%. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Carbon dioxide titration method for soil respiration measurements

    OpenAIRE

    Martín Rubio, Luis

    2017-01-01

    This thesis was commissioned by Tampere University of Applied Sciences, which was interested in studying and developing a titration measurement method for soil respiration and biodegradability. Some experiments were carried out measuring soil respiration for testing the method and others adding some biodegradable material like polylactic acid compressed material and 100% biodegradable plastic bags to test its biodegradability and the possibility to measure it via titration. The thesi...

  13. On the nature of oxygen-containing surface groups on carbon nanofibers and their role for platinum deposition—an xps and titration study

    NARCIS (Netherlands)

    Plomp, A.J.; Su, D.S.; de Jong, K.P.; Bitter, J.H.

    2009-01-01

    XPS and acid−base titrations were used to investigate the nature and stability of oxygen-containing surface groups on carbon nanofibers (CNF) and platinum-containing CNF. During heat treatments in inert atmosphere at 973 K all acidic (carboxylic) oxygen surface groups were removed for CNF.

  14. Thermodynamic Study of the Ion-Pair Complexation Equilibria of Dye and Surfactant by Spectral Titration and Chemometric Analysis

    Directory of Open Access Journals (Sweden)

    Hakimeh Abbasi Awal

    2017-12-01

    Full Text Available Surfactant-dye interactions are very important in chemical and dyeing processes. The dyes interact strongly with surfactant and show new spectrophotometric properties, so the UV-vis absorption spectrophotometric method has been used to study this process and extract some thermodynamic parameters. In this work, the association equilibrium between ionic dyes and ionic surfactant were studied by analyzing spectrophotometric data using chemometric methods. Methyl orange and crystal violet were selected as a model of cationic and anionic dyes respectively. Also sodium dodecyl sulphate and cetyltrimethylammonium bromide were selected as anionic and cationic surfactant, respectively. Hard model methods such as target transform fitting (TTF classical multi-wavelength fitting and soft model method such as multivariate curve resolution (MCR were used to analyze data that were recorded as a function of surfactant concentration in premicellar and postmicellar regions. Hard model methods were used to resolve data using ion-pair model in premicellar region in order to extract the concentration and spectral profiles of individual components and also related thermodynamic parameters. The equilibrium constants and other thermodynamic parameters of interaction of dyes with surfactants were determined by studying the dependence of their absorption spectra on the temperature in the range 293–308 K at concentrations of 5 × 10−6 M and 8 × 10−6 M for dye crystal violet and methyl orange, respectively. In postmicellar region, the MCR-ALS method was applied for resolving data and getting the spectra and concentration profiles in complex mixtures of dyes and surfactants.

  15. Coulometric titration of niobium in EDTA complexing solution

    International Nuclear Information System (INIS)

    Pannu, S.S.

    1976-01-01

    Constant current coulometry of Nb in EDTA was studied employing both potentiometric and amperometric end-point techniques. The titrations were based on the oxidation of Nb(IV)-EDTA with electrogenerated Fe(III) at a graphite anode. The rate of disproportionation of Nb(IV)-EDTA was found to be slow enough not to effect the accuracy sought for the titration. The coulometric titration of Nb in EDTA was found to be more accurate than in 1F sulfuric acid. The mean error in the titrations of 4.76 to 19.65 of Nb in a volume of about 100 ml of 0.02 to 0.04F EDTA was 0.13%. It was found that Ta may be tolerated to a ratio of 1:4, Ta:Nb, in a solution containing 13 mg of Nb. (author)

  16. The pH behavior of a 2-aminoethyl dihydrogen phosphate zwitterion studied with NMR-titrations

    Science.gov (United States)

    Myller, A. T.; Karhe, J. J.; Haukka, M.; Pakkanen, T. T.

    2013-02-01

    In this study a bifunctional 2-aminoethyl dihydrogen phosphate (AEPH2) was 1H and 31P NMR characterized in a pH range of 1-12 in order to determine the zwitterion properties in different pH regions in H2O and D2O solutions. NMR was also used to determine the pH range where AEPH2 exists as a zwitterion. The phosphate group has two deprotonation points, around pH 1 and 6, while the amino group deprotonates at pH 11. The zwitterion form of AEPH2 (NH3+sbnd CHsbnd CHsbnd OPOH) exists as the main ion between pH 1 and 6 in water solutions and also in the solid state.

  17. Experimental studies of gravitation and feebler forces

    International Nuclear Information System (INIS)

    Cowsik, R.

    1993-01-01

    The theoretical motivations and the experimental context pertaining to the recent experimental studies of the Weak equivalence Principle and the open-quotes Fifth Forceclose quotes are reviewed briefly. With such a backdrop, the innovative design and the technical details of the several new experiments in this area are presented with a special emphasis on the experiments underway at Gauribidanur, situated on the Deccan Plateau. These experiments jointly rule out the existence of any new forces coupling to baryon or lepton number with a coupling greater than about 10 -4 of gravitation per a.m.u. at ranges of about 0.5m and longer. In a few years the author hopes to test the weak equivalence principle with sensitivity exceeding 10 -13

  18. Molecular interaction studies of acetylcholinesterase with potential acetylcholinesterase inhibitors from the root of Rhodiola crenulata using molecular docking and isothermal titration calorimetry methods.

    Science.gov (United States)

    Li, Fa-Jie; Liu, Yuan; Yuan, Yuan; Yang, Bin; Liu, Zhen-Ming; Huang, Lu-Qi

    2017-11-01

    (-)-Epicatechin gallate ((-)-ECG), 1,2,3,4,6-O-pentagalloylglucose (PGG), rhodionin, herbacetin and rhodiosin isolated from the root of Rhodiola crenulata exhibited potent, dose-dependent inhibitory effects on acetylcholinesterase (AChE) with IC 50 ranged from 57.50±5.83 to 2.43±0.34μg/mL. With the aim of explaining the differences in activity of these active ingredients and clarifying how they inhibit AChE, the AChE-inhibitor interactions were further explored using molecular docking and isothermal titration calorimetry (ITC) methods in the present study. Molecular docking studies revealed that all compounds except PGG showed binding energy values ranging from -10.30 to -8.00kcal/mol while the binding energy of galantamine, a known AChE inhibitor, was -9.53kcal/mol; they inhibited the AChE by binding into the ligand pocket with the similar binding pattern to that of galantamine by interacting with Glu199 of AChE. Inhibition constant of these active ingredients had a positive correlation with binding energy. The interaction between AChE and PGG was further evaluated with the ITC method and the results indicated that the PGG-AChE interaction was relevant to AChE concentration. The results revealed a possible mechanism for the AChE inhibition activity of these bioactive ingredients, which may provide some help in lead compounds optimization in the future. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Studies on the lithium ion diffusion coefficients of electrospun Nb2O5 nanostructures using galvanostatic intermittent titration and electrochemical impedance spectroscopy

    International Nuclear Information System (INIS)

    Reddy, M.V.; Jose, R.; Le Viet, A.; Ozoemena, Kenneth I.; Chowdari, B.V.R.; Ramakrishna, S.

    2014-01-01

    Graphical abstract: - Highlights: • Pseudo-hexagonal (H), orthorhombic (O), and monoclinic (M) Nb 2 O 5 phases were prepared by electrospunning. • They were characterized by SEM, Galvanostatic and Impedance techniques. • D Li values by GITT for H-, O-, and M-Nb 2 O 5 are in the range, 10 −17 –10 −16 , 10 −15 –10 −14 , and 10 −13 –10 −12 cm 2 s −1 , respectively. - Abstract: We have studied the Li-diffusion coefficient values of electrospun Nb 2 O 5 nanofibers and nanonuggets for lithium batteries. In brief, Nb 2 O 5 nanofibers were prepared by electrospinning followed by sintering at temperatures range 500–1100 °C for 1 h in air to obtain pseudo-hexagonal, orthorhombic (O), and monoclinic (M) Nb 2 O 5 phases. Electrochemical properties were evaluated by galvanostatic technique at room temperature. The H-, O- and M-Nb 2 O 5 polymorphs delivered discharge capacities (at second cycle) of 152, 189 and 242 (±5) mA h g −1 , respectively. The lithium diffusion coefficients (D Li ) are calculated using galvanostatic intermittent titration technique (GITT) and electrochemical impedance spectroscopy (EIS) techniques carried at room temperature. The evaluated D Li values by GITT for H-, O-, and M-Nb 2 O 5 phases are in the range 10 −17 –10 −16 , 10 −15 –10 −14 , and 10 −13 –10 −12 cm 2 s −1 , respectively, in the voltage range 1.0–2.6 V vs. Li. D Li evaluated by EIS gave similar trend in the values but with a difference of one order higher magnitude

  20. Evaluation of an automatic uranium titration system

    International Nuclear Information System (INIS)

    Lewis, K.

    1980-01-01

    The titration system utilizes the constant current coulometric titration of Goldbeck and Lerner. U(VI) is reduced to U(IV) by Fe(II). V(V) is generated to titrate the U(IV), and the titration is followed potentiometrically. The evaluation shows that the recovery of uranium is 100% at the 40-mg level. The accuracy is generally +-0.10% or better. The smallest sample weight at which reliable results were obtained was 40 mg of uranium. Time for one analysis is 15 minutes. Advantages and disadvantages of the automated titrator are listed

  1. Automated back titration method to measure phosphate

    International Nuclear Information System (INIS)

    Comer, J.; Tehrani, M.; Avdeef, A.; Ross, J. Jr.

    1987-01-01

    Phosphate was measured in soda drinks and as an additive in flour, by a back titration method in which phosphate was precipitated with lanthanum, and the excess lanthanum was titrated with fluoride. All measurements were performed using the Orion fluoride electrode and the Orion 960 Autochemistry System. In most commercial automatic titrators, the inflection point of the titration curve, calculated from the first derivative of the curve, is used to find the equivalence polar of the titration. The inflection technique is compared with a technique based on Gran functions, which uses data collected after the end point and predicts the equivalence point accordingly

  2. Automatic titrator for high precision plutonium assay

    International Nuclear Information System (INIS)

    Jackson, D.D.; Hollen, R.M.

    1986-01-01

    Highly precise assay of plutonium metal is required for accountability measurements. We have developed an automatic titrator for this determination which eliminates analyst bias and requires much less analyst time. The analyst is only required to enter sample data and start the titration. The automated instrument titrates the sample, locates the end point, and outputs the results as a paper tape printout. Precision of the titration is less than 0.03% relative standard deviation for a single determination at the 250-mg plutonium level. The titration time is less than 5 min

  3. Manufacturing of a Secretoneurin Drug Delivery System with Self-Assembled Protamine Nanoparticles by Titration

    Science.gov (United States)

    Scheicher, Bernhard; Lorenzer, Cornelia; Gegenbauer, Katrin; Partlic, Julia; Andreae, Fritz; Kirsch, Alexander H.; Rosenkranz, Alexander R.; Werzer, Oliver

    2016-01-01

    Since therapeutic peptides and oligonucleotides are gathering interests as active pharmaceutical ingredients (APIs), nanoparticulate drug delivery systems are becoming of great importance. Thereby, the possibility to design drug delivery systems according to the therapeutic needs of APIs enhances clinical implementation. Over the last years, the focus of our group was laid on protamine-oligonucleotide-nanoparticles (so called proticles), however, the possibility to modify the size, zeta potential or loading efficiencies was limited. Therefore, at the present study we integrated a stepwise addition of protamine (titration) into the formation process of proticles loaded with the angiogenic neuropeptide secretoneurin (SN). A particle size around 130 nm was determined when proticles were assembled by the commonly used protamine addition at once. Through application of the protamine titration process it was possible to modify and adjust the particle size between approx. 120 and 1200 nm (dependent on mass ratio) without influencing the SN loading capacity. Dynamic light scattering pointed out that the difference in particle size was most probably the result of a secondary aggregation. Initially-formed particles of early stages in the titration process aggregated towards bigger assemblies. Atomic-force-microscopy images also revealed differences in morphology along with different particle size. In contrast, the SN loading was only influenced by the applied mass ratio, where a slight saturation effect was observable. Up to 65% of deployed SN could be imbedded into the proticle matrix. An in-vivo biodistribution study (i.m.) showed a retarded distribution of SN from the site of injection after the application of a SN-proticle formulation. Further, it was demonstrated that SN loaded proticles can be successfully freeze-dried and resuspended afterwards. To conclude, the integration of the protamine titration process offers new possibilities for the formulation of proticles in

  4. Desensitization by progressive up-titration prevents first-dose effects on the heart: guinea pig study with ponesimod, a selective S1P1 receptor modulator.

    Directory of Open Access Journals (Sweden)

    Markus Rey

    Full Text Available Ponesimod, a selective S1P1 receptor modulator, reduces the blood lymphocyte count in all tested species by preventing egress of T and B cells from thymus and peripheral lymphoid organs. In addition, ponesimod transiently affects heart rate and atrioventricular (AV conduction in humans, effects not observed in mice, rats, and dogs with selective S1P1 receptor modulators, suggesting that the regulation of heart rate and rhythm is species dependent. In the present study, we used conscious guinea pigs implanted with a telemetry device to investigate the effects of single and multiple oral doses of ponesimod on ECG variables, heart rate, and blood pressure. Oral administration of ponesimod did not affect the sinus rate (P rate but dose-dependently induced AV block type I to III. A single oral dose of 0.1 mg/kg had no effect on ECG variables, while a dose of 3 mg/kg induced AV block type III in all treated guinea pigs. Repeated oral dosing of 1 or 3 mg/kg ponesimod resulted in rapid desensitization, so that the second dose had no or a clearly reduced effect on ECG variables as compared with the first dose. Resensitization of the S1P1 receptor in the heart was concentration dependent. After desensitization had been induced by the first dose of ponesimod, the cardiac system remained desensitized as long as the plasma concentration was ≥75 ng/ml. By using a progressive up-titration regimen, the first-dose effect of ponesimod on heart rate and AV conduction was significantly reduced due to desensitization of the S1P1 receptor. In summary, conscious guinea pigs implanted with a telemetry device represent a useful model to study first-dose effects of S1P1 receptor modulators on heart rate and rhythm. This knowledge was translated to a dosing regimen of ponesimod to be tested in humans to avoid or significantly reduce the first-dose effects.

  5. Auto-titrating continuous positive airway pressure treatment for obstructive sleep apnoea after acute quadriplegia (COSAQ): study protocol for a randomized controlled trial.

    Science.gov (United States)

    Berlowitz, David J; Ayas, Najib; Barnes, Maree; Brown, Douglas J; Cistulli, Peter A; Geraghty, Tim; Graham, Alison; Lee, Bonsan Bonne; Morris, Meg; O'Donoghue, Fergal; Rochford, Peter D; Ross, Jack; Singhal, Balraj; Spong, Jo; Wadsworth, Brooke; Pierce, Robert J

    2013-06-19

    Quadriplegia is a severe, catastrophic injury that predominantly affects people early in life, resulting in lifelong physical disability. Obstructive sleep apnoea is a direct consequence of quadriplegia and is associated with neurocognitive deficits, sleepiness and reduced quality of life. The usual treatment for sleep apnoea is nasal continuous positive airway pressure (CPAP); however, this is poorly tolerated in quadriplegia. To encourage patients to use this therapy, we have to demonstrate that the benefits outweigh the inconvenience. We therefore propose a prospective, multinational randomized controlled trial of three months of CPAP for obstructive sleep apnoea after acute quadriplegia. Specialist spinal cord injury centres across Australia, New Zealand, the UK and Canada will recruit medically stable individuals who have sustained a (new) traumatic quadriplegia (complete or incomplete second cervical to first thoracic level lesions). Participants will be screened for obstructive sleep apnoea using full, portable sleep studies. Those with an apnoea hypopnoea index greater than 10 per hour will proceed to an initial three-night trial of CPAP. Those who can tolerate CPAP for at least 4 hours on at least one night of the initial trial will be randomized to either usual care or a 3-month period of auto-titrating CPAP. The primary hypothesis is that nocturnal CPAP will improve neuropsychological functioning more than usual care alone. The secondary hypothesis is that the magnitude of improvement of neuropsychological function will be predicted by the severity of baseline sleepiness measures, sleep fragmentation and sleep apnoea. Neuropsychological tests and full polysomnography will be performed at baseline and 3 months with interim measures of sleepiness and symptoms of autonomic dysfunction measured weekly. Spirometry will be performed monthly. Neuropsychological tests will be administered by blinded assessors. Recruitment commenced in July 2009. The results of

  6. Efficacy and safety of weight-based insulin glargine dose titration regimen compared with glucose level- and current dose-based regimens in hospitalized patients with type 2 diabetes: a randomized, controlled study.

    Science.gov (United States)

    Li, Xiaowei; Du, Tao; Li, Wangen; Zhang, Tong; Liu, Haiyan; Xiong, Yifeng

    2014-09-01

    Insulin glargine is widely used as basal insulin. However, published dose titration regimens for insulin glargine are complex. This study aimed to compare the efficacy and safety profile of a user-friendly, weight-based insulin glargine dose titration regimen with 2 published regimens. A total of 160 hospitalized patients with hyperglycemia in 3 medical centers were screened. Our inclusion criteria included age 18 to 80 years and being conscious. Exclusion criteria included pregnancy or breast-feeding and hepatic or renal dysfunction. A total of 149 patients were randomly assigned to receive weight-based, glucose level-based, or dose-based insulin glargine dose titration regimen between January 2011 and February 2013. The initial dose of insulin glargine was 0.2 U/kg. In the weight-based regimen (n = 49), the dose was titrated by increments of 0.1 U/kg daily. In the glucose level-based regimen (n = 51), the dose was titrated by 2, 4, 6, or 8 U daily when fasting blood glucose (FBG) was, respectively, between 7.0 and 7.9, 8.0 and 8.9, 9.0 and 9.9, or ≥10 mmol/L. In the current dose-based regimen (n = 49), titration was by daily increments of 20% of the current dose. The target FBG in all groups was ≤7.0 mmol/L. The incidence of hypoglycemia was recorded. One-way ANOVA and χ(2) test were used to compare data between the 3 groups. All but 1 patient who required additional oral antidiabetic medication completed the study. The mean (SD) time to achieve target FBG was 3.2 (1.2) days with the weight-based regimen and 3.7 (1.5) days with the glucose level-based regimen (P = 0.266). These times were both shorter than that achieved with the current dose-based regimen (4.8 [2.8] days; P = 0.0001 and P = 0.005, respectively). The daily doses of insulin glargine at the study end point were 0.43 (0.13) U/kg with the weight-based regimen, 0.50 (0.20) U/kg with the glucose level-based regimen, and 0.47 (0.23) U/kg with the current dose-based regimen (P = 0.184). The incidence

  7. Web-based guided insulin self-titration in patients with type 2 diabetes: the Di@log study. Design of a cluster randomised controlled trial [TC1316

    Directory of Open Access Journals (Sweden)

    Kostense Piet J

    2009-06-01

    Full Text Available Abstract Background Many patients with type 2 diabetes (T2DM are not able to reach the glycaemic target level of HbA1c Methods/Design T2DM patients (n = 248, aged 35–75 years, with an HbA1c ≥ 7.0%, eligible for treatment with insulin and able to use the internet will be selected from general practices in two different regions in the Netherlands. Cluster randomisation will be performed at the level of general practices. Patients in the intervention group will use a self-developed internet programme to assist them in self-titrating insulin. The control group will receive usual care. Primary outcome is the difference in change in HbA1c between intervention and control group. Secondary outcome measures are quality of life, treatment satisfaction, diabetes self-efficacy and frequency of hypoglycaemic episodes. Results will be analysed according to the intention-to-treat principle. Discussion An internet intervention supporting self-titration of insulin therapy in T2DM patients is an innovative patient-centred intervention. The programme provides guided self-monitoring and evaluation of health and self-care behaviours through tailored feedback on input of glucose values. This is expected to result in a better performance of self-titration of insulin and consequently in the improvement of glycaemic control. The patient will be enabled to 'discover and use his or her own ability to gain mastery over his/her diabetes' and therefore patient empowerment will increase. Based on the self-regulation theory of Leventhal, we hypothesize that additional benefits will be achieved in terms of increases in treatment satisfaction, quality of life and self-efficacy. Trial registration Dutch Trial Register TC1316.

  8. SPECIAL CONSIDERATIONS REGARDING WARFARIN DOSE TITRATION IN PATIENTS WITH ATRIAL FIBRILLATION DEPENDING ON CLINICAL FACTORS

    OpenAIRE

    E. L. Artanova; E. V. Saleeva; I. M. Sokolov; Y. G. Shvarts

    2011-01-01

    Aim. To study the relations of clinical characteristics and individual warfarin dose titration in patients with atrial fibrillation. Material and methods. Period of warfarin dose titration was analyzed in 68 patients with atrial fibrillation due to ischemic heart disease. Adjusted warfarin dose in milligram, duration of dose titration in days and maximal international normalized ratio (INR) were taken into account. Sex, age, history of myocardial infarction and stroke, concomitant diseases, a...

  9. Potentiometric titration of molybdenum (6) with a cathode-polarized solid electrode

    International Nuclear Information System (INIS)

    Boeva, L.V.; Kimstach, V.A.; Bagdasarov, K.N.

    1980-01-01

    The possibility has been studied of using solid electrodes for potentiometric precipitation titration of molybdenum (6). A cathode-polarized electrode, electrochemically covered with a molybdenum blue layer, can be used as indicator electrode. The best results were obtained during deposition of molybdenum blue on a tungsten electrode. The mechanism of electrode work during titration has been investigated. A procedure has been developed of titration of molybdenum (6) in acid solutions using hydroxylamine N-aryl derivatives as titrants

  10. Comparison study Of H{sub 2}O determination in UO{sub 2} powder by using MEA (Moisture Evaluation Analysis) and KFT (Karl Fischer Titration); Studi banding penentuan kadar H{sub 2}O dalam serbuk UO{sub 2} menggunakan metoda MEA (Moisture Evaluation Analysis) dan KFT (Karl Fischer Titration)

    Energy Technology Data Exchange (ETDEWEB)

    Farida,; Yudhi, N; Lilis, W; Putro, P K [Center for Development of Nuclear Fuel and Recycling Technology, National Atomic Energy Agency, Serpong (Indonesia)

    2000-03-08

    To find out an analytical method to determine H{sub 2}O content in UO{sub 2} powder as fuel elements of power reactors which is simple, economical, precise, and accurate, it is necessary to do comparison study of H{sub 2}O content determination using MEA method which is based on electrolysis process with two helically wound electrodes which contains P{sub 2} O{sub 5} that has function to absorb water steam. The platinum electrodes have a 67 Volt potential on them. The quantity of charge required to electrolyse 0.1 {mu}gr of H{sub 2}O is a constant which is the basic of the electronic measurement. In KFT method is based on volumetric titration using the one component reagent hydronol composite contain all reactants i.e. iodine, sulfur dioxide and imidazole as the base, dissolved in a suitable alcohol. The t- (student) test show that there is no different result significantly between those method. The H{sub 2}O contain obtained is 0.956{+-}0.0095 %, for MEA method and 0.953{+-}0.023 % for KFT method. (author)

  11. Risks and Benefits of Rapid Clozapine Titration.

    Science.gov (United States)

    Lochhead, Jeannie D; Nelson, Michele A; Schneider, Alan L

    2016-05-18

    Clozapine is often considered the gold standard for the treatment of schizophrenia. Clinical guidelines suggest a gradual titration over 2 weeks to reduce the risks of adverse events such as seizures, hypotension, agranulocytosis, and myocarditis. The slow titration often delays time to therapeutic response. This raises the question of whether, in some patients, it may be safe to use a more rapid clozapine titration. The following case illustrates the potential risks associated with the use of multiple antipsychotics and rapid clozapine titration. We present the case of a young man with schizophrenia who developed life threatening neuroleptic malignant syndrome (NMS) during rapid clozapine titration and treatment with multiple antipsychotics. We were unable to find another case in the literature of NMS associated with rapid clozapine titration. This case is meant to urge clinicians to carefully evaluate the risks and benefits of rapid clozapine titration, and to encourage researchers to further evaluate the safety of rapid clozapine titration. Rapid clozapine titration has implications for decreasing health care costs associated with prolonged hospitalizations, and decreasing the emotional suffering associated with uncontrolled symptoms of psychosis. Clozapine is considered the most effective antipsychotic available thus efforts should focus on developing strategies that would allow for safest and most efficient use of clozapine to encourage its utilization for treatment resistance schizophrenia.

  12. Risks and benefits of rapid clozapine titration

    Directory of Open Access Journals (Sweden)

    Jeannie D. Lochhead

    2016-05-01

    Full Text Available Clozapine is often considered the gold standard for the treatment of schizophrenia. Clinical guidelines suggest a gradual titration over 2 weeks to reduce the risks of adverse events such as seizures, hypotension, agranulocytosis, and myocarditis. The slow titration often delays time to therapeutic response. This raises the question of whether, in some patients, it may be safe to use a more rapid clozapine titration. The following case illustrates the potential risks associated with the use of multiple antipsychotics and rapid clozapine titration. We present the case of a young man with schizophrenia who developed life threatening neuroleptic malignant syndrome (NMS during rapid clozapine titration and treatment with multiple antipsychotics. We were unable to find another case in the literature of NMS associated with rapid clozapine titration. This case is meant to urge clinicians to carefully evaluate the risks and benefits of rapid clozapine titration, and to encourage researchers to further evaluate the safety of rapid clozapine titration. Rapid clozapine titration has implications for decreasing health care costs associated with prolonged hospitalizations, and decreasing the emotional suffering associated with uncontrolled symptoms of psychosis. Clozapine is considered the most effective antipsychotic available thus efforts should focus on developing strategies that would allow for safest and most efficient use of clozapine to encourage its utilization for treatment resistance schizophrenia.

  13. Microcalorimetric and potentiometric titration studies on the adsorption of copper by P. putida and B. thuringiensis and their composites with minerals

    International Nuclear Information System (INIS)

    Fang Linchuan; Cai Peng; Li Pengxiang; Wu Huayong; Liang Wei; Rong Xingmin; Chen Wenli; Huang Qiaoyun

    2010-01-01

    In order to have a better understanding of the interactions of heavy metals with bacteria and minerals in soil and associated environments, isothermal titration calorimetry (ITC), potentiometric titration and equilibrium sorption experiments were conducted to investigate the adsorption behavior of Cu(II) by Bacillus thuringiensis, Pseudomonas putida and their composites with minerals. The interaction of montmorillonite with bacteria increased the reactive sites and resulted in greater adsorption for Cu(II) on their composites, while decreased adsorption sites and capacities for Cu(II) were observed on goethite-bacteria composites. A gram-positive bacterium B. thuringiensis played a more important role than a gram-negative bacterium P. putida in determining the properties of the bacteria-minerals interfaces. The enthalpy changes (ΔH ads ) from endothermic (6.14 kJ mol -1 ) to slightly exothermic (-0.78 kJ mol -1 ) suggested that Cu(II) is complexed with the anionic oxygen ligands on the surface of bacteria-mineral composites. Large entropies (32.96-58.89 J mol -1 K -1 ) of Cu(II) adsorption onto bacteria-mineral composites demonstrated the formation of inner-sphere complexes in the presence of bacteria. The thermodynamic data implied that Cu(II) mainly bound to the carboxyl and phosphoryl groups as inner-sphere complexes on bacteria and mineral-bacteria composites.

  14. Microcalorimetric and potentiometric titration studies on the adsorption of copper by P. putida and B. thuringiensis and their composites with minerals

    Energy Technology Data Exchange (ETDEWEB)

    Fang Linchuan [State Key Laboratory of Agricultural Microbiology, Huazhong Agricultural University, Wuhan 430070 (China); Key Laboratory of Subtropical Agriculture and Environment, Ministry of Agriculture, College of Resources and Environment, Huazhong Agricultural University, Wuhan 430070 (China); Cai Peng; Li Pengxiang; Wu Huayong; Liang Wei; Rong Xingmin [Key Laboratory of Subtropical Agriculture and Environment, Ministry of Agriculture, College of Resources and Environment, Huazhong Agricultural University, Wuhan 430070 (China); Chen Wenli [State Key Laboratory of Agricultural Microbiology, Huazhong Agricultural University, Wuhan 430070 (China); Huang Qiaoyun, E-mail: qyhuang@mail.hzau.edu.cn [State Key Laboratory of Agricultural Microbiology, Huazhong Agricultural University, Wuhan 430070 (China); Key Laboratory of Subtropical Agriculture and Environment, Ministry of Agriculture, College of Resources and Environment, Huazhong Agricultural University, Wuhan 430070 (China)

    2010-09-15

    In order to have a better understanding of the interactions of heavy metals with bacteria and minerals in soil and associated environments, isothermal titration calorimetry (ITC), potentiometric titration and equilibrium sorption experiments were conducted to investigate the adsorption behavior of Cu(II) by Bacillus thuringiensis, Pseudomonas putida and their composites with minerals. The interaction of montmorillonite with bacteria increased the reactive sites and resulted in greater adsorption for Cu(II) on their composites, while decreased adsorption sites and capacities for Cu(II) were observed on goethite-bacteria composites. A gram-positive bacterium B. thuringiensis played a more important role than a gram-negative bacterium P. putida in determining the properties of the bacteria-minerals interfaces. The enthalpy changes ({Delta}H{sub ads}) from endothermic (6.14 kJ mol{sup -1}) to slightly exothermic (-0.78 kJ mol{sup -1}) suggested that Cu(II) is complexed with the anionic oxygen ligands on the surface of bacteria-mineral composites. Large entropies (32.96-58.89 J mol{sup -1} K{sup -1}) of Cu(II) adsorption onto bacteria-mineral composites demonstrated the formation of inner-sphere complexes in the presence of bacteria. The thermodynamic data implied that Cu(II) mainly bound to the carboxyl and phosphoryl groups as inner-sphere complexes on bacteria and mineral-bacteria composites.

  15. Microcalorimetric and potentiometric titration studies on the adsorption of copper by P. putida and B. thuringiensis and their composites with minerals.

    Science.gov (United States)

    Fang, Linchuan; Cai, Peng; Li, Pengxiang; Wu, Huayong; Liang, Wei; Rong, Xingmin; Chen, Wenli; Huang, Qiaoyun

    2010-09-15

    In order to have a better understanding of the interactions of heavy metals with bacteria and minerals in soil and associated environments, isothermal titration calorimetry (ITC), potentiometric titration and equilibrium sorption experiments were conducted to investigate the adsorption behavior of Cu(II) by Bacillus thuringiensis, Pseudomonas putida and their composites with minerals. The interaction of montmorillonite with bacteria increased the reactive sites and resulted in greater adsorption for Cu(II) on their composites, while decreased adsorption sites and capacities for Cu(II) were observed on goethite-bacteria composites. A gram-positive bacterium B. thuringiensis played a more important role than a gram-negative bacterium P. putida in determining the properties of the bacteria-minerals interfaces. The enthalpy changes (DeltaH(ads)) from endothermic (6.14 kJ mol(-1)) to slightly exothermic (-0.78 kJ mol(-1)) suggested that Cu(II) is complexed with the anionic oxygen ligands on the surface of bacteria-mineral composites. Large entropies (32.96-58.89 J mol(-1) K(-1)) of Cu(II) adsorption onto bacteria-mineral composites demonstrated the formation of inner-sphere complexes in the presence of bacteria. The thermodynamic data implied that Cu(II) mainly bound to the carboxyl and phosphoryl groups as inner-sphere complexes on bacteria and mineral-bacteria composites. Copyright 2010 Elsevier B.V. All rights reserved.

  16. Method for linearizing the potentiometric curves of precipitation titration in nonaqueous and aqueous-organic solutions

    International Nuclear Information System (INIS)

    Bykova, L.N.; Chesnokova, O.Ya.; Orlova, M.V.

    1995-01-01

    The method for linearizing the potentiometric curves of precipitation titration is studied for its application in the determination of halide ions (Cl - , Br - , I - ) in dimethylacetamide, dimethylformamide, in which titration is complicated by additional equilibrium processes. It is found that the method of linearization permits the determination of the titrant volume at the end point of titration to high accuracy in the case of titration curves without a potential jump in the proximity of the equivalent point (5 x 10 -5 M). 3 refs., 2 figs., 3 tabs

  17. TEROIDES THE STUDY OF THE EFFECT OF HIGH AND LOW STARTING TITRE IN THE MODEL ENVIRONMENTS TO CHANGES IN ACTIVE AND TITRATABLE ACIDITY DURING THE CULTIVATION OF WHITE CABBAGE VARIETIES PARUS LACTIC ACID BACTERIA L. LACTIS AND L. MESENTEROIDES

    Directory of Open Access Journals (Sweden)

    V. V. Kondratenko

    2017-01-01

    Full Text Available The aim of the research was to study the dynamics of active and titratable acidity with a low and high initial titer, while cultivating white head cabbage of the variety ‘Parus’ with lactic acid bacteria Leuconostoc lactis VKPM V-12150 and Leuconostoc mesenteroides subsp. mesenteroides VKPM V-8818 in the basic model medium (BMS and the modified model medium (MMC during fermentation . In this experiment, two important questions were considered: the creation of favorable conditions for the growth of lactic acid microorganisms and the suppression of undesirable pathogenic microflora, which can eventually lead to product spoilage. One of the key questions is to scale the results of studies related to the fermentation of plant objects by microorganisms on initially non-sterile raw materials that is the requirement to create as possible fast the conditions that restrain the reproduction of Cl. botulinum, preventing toxin accumulation in the product. Therefore, an important factor is the observance for the necessary boundary condition where for international standards, it reaches pH ≤ 4.6, and for Russian standards it reaches pH ≤ 4.2. Hence, an analysis of the experimental data showed that these boundary conditions were reached after the expiration of essentially different time intervals during the cultivation of microorganisms with different starting titers. As a result, it was shown with which lactic acid microorganisms the optimal parameters for the dynamics of active and titratable acidity were obtained, when the boundary condition reached pH 4.2. Since this value determines more "stringent" requirements for product safety. As a result of studies it was found that optimal parameters for the dynamics of active and titratable acidity when a limit pH value of 4.2 is obtained in the cultivation of lactic acid bacteria L. mesenteroides in the MMC, revealing that the value of the starting titer ranging from 3*103 to 3*105 CFU/g.

  18. The role of titration schedule of topiramate for the development of depression in patients with epilepsy.

    Science.gov (United States)

    Mula, Marco; Hesdorffer, Dale C; Trimble, Michael; Sander, Josemir W

    2009-05-01

    To determine whether a fast titration schedule of topiramate (TPM) has different effects on the occurrence of depression, in relation to other risk factors for TPM-induced depression, including history of depression (HxDEP), febrile seizures (FS), and hippocampal sclerosis (HS). Using data from a large case registry of patients prescribed TPM, two models were constructed: Model 1 examined the independent effect of rapid TPM titration after separate adjustment for FS, HxDEP, and HS. Model 2 examined effect of the cooccurrence of rapid titration on the development of depression with each of these risk factors. A total of 423 patients were included (51.8% females), mean age (SD) 35.5 (11.8) years, mean duration of epilepsy of 22.2 (11.5) years. Forty-four patients (10.4%) developed depression during TPM therapy. A rapid TPM titration was associated with 5-fold increased risk of depression that increased to 12.7-fold in the presence of both FS and rapid TPM titration, 23.3-fold in the presence of both HxDEP and rapid TPM titration, and 7.6-fold in the presence of both HS and rapid TPM titration schedule. Our study suggests that a rapid titration schedule is associated with an increased risk of developing depression during TPM therapy. HxDEP and FS are major contraindications to the use of a rapid titration, with a 23.3-fold and 12.7 fold increased risk, respectively.

  19. Nap-titration : An effective alternative for continuous positive airway pressure titration

    NARCIS (Netherlands)

    Hoekema, A; Stegenga, B; Meinesz, AF; van der Hoeven, JH; Wijkstra, PJ

    When treating Obstructive Steep Apnea-Hypopnea Syndrome (OSAHS) several alternatives for standard (manual) continuous positive airway pressure (CPAP) titration are feasible. A practical alternative is titration without polysomnography during an afternoon nap (Nap-titration). The aim of the present

  20. Contributions to the theory of catalytic titrations-III Neutralization catalytic titrations.

    Science.gov (United States)

    Gaál, F F; Abramović, B F

    1985-07-01

    Neutralization catalytic titrations of weak monoprotic adds and bases with both volumetric and coulometric addition of the titrant (strong base/acid) have been simulated by taking into account the equilibrium concentration of the catalyst during the titration. The influence of several factors on the shape of the simulated catalytic titration curve has been investigated and is discussed.

  1. Two-phase titration of cerium(III) by permanganate

    International Nuclear Information System (INIS)

    Lazarev, A.I.; Lazareva, V.I.; Gerko, V.V.

    1987-01-01

    This paper presents a method for the two-phase titrimetric determination of cerium(III) with permanganate which does not require an expenditure of sugar and preliminary removal of chlorides and nitrates. The interaction of cerium(III) with permanganate at room temperature was studied as a function of the pH, the concentration of pyrophosphate, tetraphenylphosphonium (TPP), permanganate, and extraneous compounds, the rate of titration, and the time of stay of the solution in air before titration. The investigations were conducted according to the following methodology: water, solution of cerium(III) pyrophosphate, and TPP were introduced into an Erlenmeyer flask with a side branch near the bottom for clearer observation of the color of the chloroform phase. The authors established the given pH value, poured the water into a volume of 50 ml, and added chloroform. The result was titrated with permanganate solutions of various concentrations until a violet color appeared in the chloroform phase

  2. Error assessment in recombinant baculovirus titration: evaluation of different methods.

    Science.gov (United States)

    Roldão, António; Oliveira, Rui; Carrondo, Manuel J T; Alves, Paula M

    2009-07-01

    The success of baculovirus/insect cells system in heterologous protein expression depends on the robustness and efficiency of the production workflow. It is essential that process parameters are controlled and include as little variability as possible. The multiplicity of infection (MOI) is the most critical factor since irreproducible MOIs caused by inaccurate estimation of viral titers hinder batch consistency and process optimization. This lack of accuracy is related to intrinsic characteristics of the method such as the inability to distinguish between infectious and non-infectious baculovirus. In this study, several methods for baculovirus titration were compared. The most critical issues identified were the incubation time and cell concentration at the time of infection. These variables influence strongly the accuracy of titers and must be defined for optimal performance of the titration method. Although the standard errors of the methods varied significantly (7-36%), titers were within the same order of magnitude; thus, viral titers can be considered independent of the method of titration. A cost analysis of the baculovirus titration methods used in this study showed that the alamarblue, real time Q-PCR and plaque assays were the most expensive techniques. The remaining methods cost on average 75% less than the former methods. Based on the cost, time and error analysis undertaken in this study, the end-point dilution assay, microculture tetrazolium assay and flow cytometric assay were found to be the techniques that combine all these three main factors better. Nevertheless, it is always recommended to confirm the accuracy of the titration either by comparison with a well characterized baculovirus reference stock or by titration using two different methods and verification of the variability of results.

  3. [Comparison of different continuous positive airway pressure titration methods for obstructive sleep apnea hypopnea syndrome].

    Science.gov (United States)

    Li, Jingjing; Ye, Jingying; Zhang, Peng; Kang, Dan; Cao, Xin; Zhang, Yuhuan; Ding, Xiu; Zheng, Li; Li, Hongguang; Bian, Qiuli

    2014-10-01

    To explore whether there were differences between the results of automatic titration and the results of manual titration for positive airway pressure treatment in patients with obstructive sleep apnea hypopnea syndrome (OSAHS) and its influencing factors, the results might provide a theoretical basis for the rational use of two pressure titration methods. Sixty one patients with OSAHS were included in this study. All patients underwent a manual titration and an automatic titration within one week. The clinical informations, polysomnography data, and the results of both two titration of all patients were obtained for analysis. The overall apnea/hypopnea index was (63.1 ± 17.7)/h, with a range of 14.9/h to 110.4/h. The treatment pressure of manual titration was (8.4 ± 2.1) cmH(2)O, which was significantly lower than the treatment pressure of automatic titration, (11.5 ± 2.7) cmH(2)O (t = -9.797, P titration and manual titration), it was found that the pressure of automatic titration was significantly higher in patients with a ΔP > 3 cmH(2)O than in patients with a ΔP ≤ 3 cmH(2)O, which was (13.3 ± 2.3) cmH(2)O vs (10.0 ± 2.0) cmH(2)O (t = -6.159, P titration between these two groups, which was (8.6 ± 2.4) cmH(2)O vs (8.3 ± 2.0)cmH(2)O (P > 0.05). There was no significant difference in age, body mass index, neck circumference, abdomen circumference, apnea hypopnea index, and arterial oxygen saturation between these two groups. The treatment pressure of automatic titration is usually higher than that of manual titration. For patients with a high treatment pressure which is derived from automatic titration, a suggestion about manual titration could be given to decrease the potential treatment pressure of continuous positive airway pressure, which may be helpful in improving the comfortableness and the compliance of this treatment.

  4. Quick titration of pergolide in cotreatment with domperidone is safe and effective

    NARCIS (Netherlands)

    Jansen, PAF; Herings, RMC; Samson, MM; Schuurmans-Daemen, LMPJ; Hovestadt, A; Verhaar, HJJ; Van Laar, T; de Vreede, P.

    2001-01-01

    The purpose of the study was to analyze efficacy and safety of quick pergolide titration combined with domperidone. In an open-label prospective study, pergolide was titrated in 16 days to a maximum of 3 mg/d doses as adjunctive treatment to L-Dopa in 10 elderly patients with Parkinson's disease.

  5. A Tabular Approach to Titration Calculations

    Science.gov (United States)

    Lim, Kieran F.

    2012-01-01

    Titrations are common laboratory exercises in high school and university chemistry courses, because they are easy, relatively inexpensive, and they illustrate a number of fundamental chemical principles. While students have little difficulty with calculations involving a single titration step, there is a significant leap in conceptual difficulty…

  6. Symmetry Properties of Potentiometric Titration Curves.

    Science.gov (United States)

    Macca, Carlo; Bombi, G. Giorgio

    1983-01-01

    Demonstrates how the symmetry properties of titration curves can be efficiently and rigorously treated by means of a simple method, assisted by the use of logarithmic diagrams. Discusses the symmetry properties of several typical titration curves, comparing the graphical approach and an explicit mathematical treatment. (Author/JM)

  7. Potentiometric titration of metal ions in ethanol.

    Science.gov (United States)

    Gibson, Graham T T; Mohamed, Mark F; Neverov, Alexei A; Brown, R S

    2006-09-18

    The potentiometric titrations of Zn2+, Cu2+ and 12 Ln3+ metal ions were obtained in ethanol to determine the titration constants (defined as the at which the [-OEt]/[Mx+]t ratios are 0.5, 1.5, and 2.5) and in two cases (La3+ and Zn2+) a complete speciation diagram. Several simple monobasic acids and aminium ions were also titrated to test the validity of experimental titration measurements and to establish new constants in this medium that will be useful for the preparation of buffers and standard solutions. The dependence of the titration constants on the concentration and type of metal ion and specific counterion effects is discussed. In selected cases, the titration profiles were analyzed using a commercially available fitting program to obtain information about the species present in solution, including La3+ for which a dimer model is proposed. The fitting provides the microscopic values for deprotonation of one to four metal-bound ethanol molecules. Kinetics for the La3+-catalyzed ethanolysis of paraoxon as a function of are presented and analyzed in terms of La3+ speciation as determined by the analysis of potentiometric titration curves. The stability constants for the formation of Zn2+ and Cu2+ complexes with 1,5,9-triazacyclododecane as determined by potentiometric titration are presented.

  8. Frictional forces between cohesive powder particles studied by AFM

    International Nuclear Information System (INIS)

    Jones, Robert; Pollock, Hubert M; Geldart, Derek; Verlinden-Luts, Ann

    2004-01-01

    A range of commercially important powders (hydrated alumina, limestone, titania and zeolite) and glass ballotini were attached to atomic force microscope cantilevers, and inter-particle friction forces studied in air using lateral force microscopy (LFM). The in situ calibration procedure for friction forces is described. LF images, line profiles, LF histograms, surface roughness, pull-off forces, and the load dependence of friction in the range 0-25 nN were studied for both particle-particle and particle-wall (steel) contacts. The single-particle friction results are discussed in terms of contact mechanics theory. Particle-particle contacts showed load-dependent friction, involving single asperity contacts (non-linear behaviour) or multi-asperity contacts (linear behaviour). Particle-wall contacts usually showed little load dependence and were more adhesive. The results are also related to shear stress-normal stress data (yield loci) for the same materials from bulk shear testers

  9. A study on forces acting on a flapping wing

    Directory of Open Access Journals (Sweden)

    Cetiner O.

    2013-04-01

    Full Text Available In order to study the forces acting on a flapping wing, an experimental investigation is performed in steady water flow. In this study, a SD7003 airfoil undergoes combined pitching and plunging motion which simulates the forward flight of small birds. The frequency of pitching motion is equal to the frequency of plunging motion and pitch leads the plunge by a phase angle of 90 degrees. The experiments are conducted at Reynolds numbers of 2500 ≤ Re ≤ 13700 and the vortex formation is recorded using the digital particle image velocimetry (DPIV technique. A prediction of thrust force and efficiency is calculated from the average wake deficit of DPIV data, the near-wake vorticity patterns and time dependent velocity vectors are determined to comment on the thrust and drag indication. Direct force measurements are attempted using a Force/Torque sensor which is capable of measuring forces and moments in three axial directions.

  10. Potentiometric Titration Method for Quantitative Determination of Hydrogen Peroxide

    National Research Council Canada - National Science Library

    Bessette, Russell R

    2005-01-01

    An electrochemical potentiometric titration method that entails titration of a known volume of a catholyte containing an unknown amount of hydrogen peroxide in a titration cell having two electrodes...

  11. A study on fixing force generation mechanism of ER gel

    International Nuclear Information System (INIS)

    Tanaka, H; Kakinuma, Y; Aoyama, T; Anzai, H

    2009-01-01

    Electro-rheological Gel (ERG) is a new functional elastomer which changes its surface frictional and adhesive property according to the intensity of applied electrical field. This unique property is called ERG effect. The upper sliding electrode placed on the surface of ERG is fixed by the adhesive effect of ERG under electrical field. Variable fixing forces due to adhesion are generated by this effect. However, relationship between physical factors and generated fixing force has not yet been clarified. In this study, physical mechanism of fixing phenomenon is elucidated experimentally from the view point of frictional force and adhesive force. From the results, empirical equation of generated fixing force is originally derived to establish the theory of ERG effect.

  12. A study on fixing force generation mechanism of ER gel

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, H; Kakinuma, Y; Aoyama, T [School of Integrated Design Engineering, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522 (Japan); Anzai, H [Fujikura kasei Co., Ltd., 2-6-15 Shibakouen, Minato-ku, Tokyo (Japan)], E-mail: h-tanaka@ina.sd.keio.ac.jp

    2009-02-01

    Electro-rheological Gel (ERG) is a new functional elastomer which changes its surface frictional and adhesive property according to the intensity of applied electrical field. This unique property is called ERG effect. The upper sliding electrode placed on the surface of ERG is fixed by the adhesive effect of ERG under electrical field. Variable fixing forces due to adhesion are generated by this effect. However, relationship between physical factors and generated fixing force has not yet been clarified. In this study, physical mechanism of fixing phenomenon is elucidated experimentally from the view point of frictional force and adhesive force. From the results, empirical equation of generated fixing force is originally derived to establish the theory of ERG effect.

  13. An exploratory trial of basal and prandial insulin initiation and titration for type 2 diabetes in primary care with adjunct retrospective continuous glucose monitoring: INITIATION study.

    Science.gov (United States)

    Blackberry, Irene D; Furler, John S; Ginnivan, Louise E; Manski-Nankervis, Jo-Anne; Jenkins, Alicia; Cohen, Neale; Best, James D; Young, Doris; Liew, Danny; Ward, Glenn; O'Neal, David N

    2014-11-01

    To evaluate basal and prandial insulin initiation and titration in people with type 2 diabetes mellitus (T2DM) in primary care and to explore the feasibility of retrospective-continuous glucose monitoring (r-CGM) in guiding insulin dosing. The new model of care features General Practitioners (GPs) and Practice Nurses (PNs) working in an expanded role, with Credentialed Diabetes Educator - Registered Nurse (CDE-RN) support. Insulin-naïve T2DM patients (HbA1c >7.5% [>58 mmol/mol] despite maximal oral therapy) from 22 general practices in Victoria, Australia commenced insulin glargine, with glulisine added as required. Each was randomised to receive r-CGM or self-monitoring of blood glucose (SMBG). Glycaemic control (HbA1c) was benchmarked against specialist ambulatory patients referred for insulin initiation. Ninety-two patients mean age (range) 59 (28-77) years; 40% female; mean (SD) diabetes duration 10.5 (6.1) years participated. HbA1c decreased from (median (IQR)) 9.9 (8.8, 11.2)%; 85 (73, 99) mmol/mol to 7.3 (6.9, 7.8)%; 56 (52, 62) mmol/mol at 24 weeks (p < 0.0001). Comparing r-CGM (n = 46) with SMBG (n = 42), there were no differences in major hypoglycaemia (p=0.17) or ΔHbA1c (p = 0.31). More r-CGM than SMBG participants commenced glulisine (26/48 vs. 7/44; p < 0.001). Results were comparable to 82 benchmark patients, with similar low rates of major hypoglycaemia (2/89 vs. 0/82; p = 0.17) and less loss to follow up in the INITIATION group (3/92 vs. 14/82; p = 0.002). Insulin initiation and titration for T2DM patients in primary care was safe and improved HbA1c with low rates of major hypoglycaemia. CDE-RNs were effective in a new consultant role. r-CGM use in primary care was feasible and enhanced post-prandial hyperglycaemia recognition. Trial registration ACTRN12610000797077. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  14. Studying the Adhesion Force and Glass Transition of Thin Polystyrene Films by Atomic Force Microscopy

    DEFF Research Database (Denmark)

    Kang, Hua; Qian, Xiaoqin; Guan, Li

    2018-01-01

    microscopy (AFM)-based forcedistance curve to study the relaxation dynamics and the film thickness dependence of glass transition temperature (T-g) for normal thin polystyrene (PS) films supported on silicon substrate. The adhesion force (F-ad) between AFM tip and normal thin PS film surfaces...

  15. Study of Adhesion Interaction Using Atomic Force Microscopy

    Science.gov (United States)

    Grybos, J.; Pyka-Fosciak, G.; Lebed, K.; Lekka, M.; Stachura, Z.; Styczeñ, J.

    2003-05-01

    An atomic force microscope is a useful tool to study the interaction forces at molecular level. In particular the atomic force microscope can measure an unbinding force needed to separate the two single molecule complexes. Recent studies have shown that such unbinding force depends linearly on the logarithm of the applied loading rate, defined as a product of scanning velocity and the spring constant characterizing the investigated system (cantilever vs. surface). This dependence can be used to study the energy landscape shape of a molecular complex by the estimation of energy barrier locations and the related dissociation rates. In the present work the complex consisting of ethylene(di)aminetetraacetic acid and the bovine serum albumin was measured. The dependence between the unbinding force and the logarithm of the loading rate was linear. Using the Bell model describing the dissociation of the above molecules caused by the action of the external bond breaking force, two parameters were estimated: the dissociation rate and the position of the energy barrier needed to overcome during a transition from a bound to unbound state. The obtained results are similar to those obtained for a typical ligand--receptor interaction.

  16. Linear Titration Curves of Acids and Bases.

    Science.gov (United States)

    Joseph, N R

    1959-05-29

    The Henderson-Hasselbalch equation, by a simple transformation, becomes pH - pK = pA - pB, where pA and pB are the negative logarithms of acid and base concentrations. Sigmoid titration curves then reduce to straight lines; titration curves of polyelectrolytes, to families of straight lines. The method is applied to the titration of the dipeptide glycyl aminotricarballylic acid, with four titrable groups. Results are expressed as Cartesian and d'Ocagne nomograms. The latter is of a general form applicable to polyelectrolytes of any degree of complexity.

  17. Non-aqueous titration of hydroxamic acids.

    Science.gov (United States)

    Stamey, T W; Christian, R

    1966-01-01

    Benzohydroxamic acid is titrated with 0.1M tetrabutyl-anunonium hydroxide in nine non-aqueous solvents with three different indicating electrodes. The best results are obtained using dimethylformamide as solvent and platinum-platinum electrodes. Four monoprotic and three diprotic hydroxamie acids and iron(III) benzohydroxamate have been successfully titrated with this system. The effect of quantitative additions of carbon dioxide to the titrant on its apparent molarity are found to be dependent on the amount added, the strength and sample size of acid titrated and the solvent used.

  18. Determination of substances by radiothermometric titration

    International Nuclear Information System (INIS)

    Tolgyessy, J.; Lesny, J.

    1976-01-01

    For determination, nitrogen is bubbled through a solution containing radioactive Kr, Xe, Rn or another aerogen in addition to the substance determined. A continuous or intermittent addition of the titrating solution results in the release of reaction heat, thus increasing the temperature of the reaction mixture, which releases a radioactive gas. Upon reaching the equivalence point, the cold titrating reagent cools the reaction mixture, thus reducing the radioactive substance release. The equivalence point lies at the point of intersection of the extended linear parts of the curve of the dependence of released radioactivity on the volume of the titrating solution added. (M.K.)

  19. Does the commonly used pH-stat method with back titration really quantify the enzymatic digestibility of lipid drug delivery systems? A case study on solid lipid nanoparticles (SLN).

    Science.gov (United States)

    Heider, Martha; Hause, Gerd; Mäder, Karsten

    2016-12-01

    Enzymatic digestion of lipid drug carriers is very important. Commonly, pancreatin induced formation of fatty acids is monitored by the pH-stat method, which provides a fast, but unspecific readout. However, according to the literature, the pKa values of long chain fatty acids are strongly dependent on the local environment and might vary between 4.2 and 10.15. The high pKa values would lead to an incomplete detection of the lipid digestion and false results. In order to investigate these issues in more detail, we produced cetyl palmitate solid lipid nanoparticles (CP-SLN) stabilized with poloxamer 188 or polysorbate 80. The digestion of CP-SLN was investigated by two different and independent readouts. A HPTLC assay was used in addition to the pH-stat method (with or without back titration). An incomplete digestion of CP-SLN was observed with all methods. Partial digestion of polysorbate 80 contributed to the formation of fatty acids. Depending on the investigated system and the experimental conditions (FaSSIF or FeSSIF) the results of both readout methods were comparable or not. For example, in FeSSIF conditions, the values detected by HPTLC were roughly twice as high as the pH-stat results. Our findings on solid lipids agree with data from Helbig et al. on lipid emulsions, where a gas chromatography method detected much higher values than the pH-stat assay (Food Hydrocoll. 28 (2012) 10-19). The results of our pH-stat experiments with back titration at different pH values showed increased values for fatty acids from pH 7.5 to pH 10. The values obtained by back titration at high pH values (pH 9 or higher) did exceed the digestion values measured by HPTLC. Therefore, we conclude that the pH-stat method might give the same results as more specific reference methods, but it might also both under- (without back titration) or overestimate (with back titration) the enzymatic digestion of lipid drug delivery systems. A further outcome of our study was the proof that

  20. The titration of carboxyl-terminated monolayers revisited: in situ calibrated fourier transform infrared study of well-defined monolayers on silicon.

    Science.gov (United States)

    Aureau, D; Ozanam, F; Allongue, P; Chazalviel, J-N

    2008-09-02

    The acid-base equilibrium at the surface of well-defined mixed carboxyl-terminated/methyl-terminated monolayers grafted on silicon (111) has been investigated using in situ calibrated infrared spectroscopy (attenuated total reflectance (ATR)) in the range of 900-4000 cm (-1). Spectra of surfaces in contact with electrolytes of various pH provide a direct observation of the COOH COO (-) conversion process. Quantitative analysis of the spectra shows that ionization of the carboxyl groups starts around pH 6 and extends over more than 6 pH units: approximately 85% ionization is measured at pH 11 (at higher pH, the layers become damaged). Observations are consistently accounted for by a single acid-base equilibrium and discussed in terms of change in ion solvation at the surface and electrostatic interactions between surface charges. The latter effect, which appears to be the main limitation, is qualitatively accounted for by a simple model taking into account the change in the Helmholtz potential associated with the surface charge. Furthermore, comparison of calculated curves with experimental titration curves of mixed monolayers suggests that acid and alkyl chains are segregated in the monolayer.

  1. Antihypertensive Effects, Molecular Docking Study, and Isothermal Titration Calorimetry Assay of Angiotensin I-Converting Enzyme Inhibitory Peptides from Chlorella vulgaris.

    Science.gov (United States)

    Xie, Jingli; Chen, Xujun; Wu, Junjie; Zhang, Yanyan; Zhou, Yan; Zhang, Lujia; Tang, Ya-Jie; Wei, Dongzhi

    2018-02-14

    The aim of this work is to explore angiotensin I-converting enzyme (ACE) inhibitory peptides from Chlorella vulgaris (C. vulgaris) and discover the inhibitory mechanism of the peptides. After C. vulgaris proteins were gastrointestinal digested in silico, several ACE inhibitory peptides with C-terminal tryptophan were screened. Among them, two novel noncompetitive ACE inhibitors, Thr-Thr-Trp (TTW) and Val-His-Trp (VHW), exhibited the highest inhibitory activity indicated by IC 50 values 0.61 ± 0.12 and 0.91 ± 0.31 μM, respectively. Both the peptides were demonstrated stable against gastrointestinal digestion and ACE hydrolysis. The peptides were administrated to spontaneously hypertensive rats (SHRs) in the dose 5 mg/kg body weight, and VHW could decrease 50 mmHg systolic blood pressure of SHRs (p < 0.05). Molecular docking displayed that both TTW and VHW formed six hydrogen bonds with active site pockets of ACE. Besides, isothermal titration calorimetry assay discovered that VHW could form more stable complex with ACE than TTW. Therefore, VHW was an excellent ACE inhibitor.

  2. The formation of amino acid and dipeptide complexes with α-cyclodextrin and cucurbit[6]uril in aqueous solutions studied by titration calorimetry

    International Nuclear Information System (INIS)

    Buschmann, H.-J.; Schollmeyer, E.; Mutihac, L.

    2003-01-01

    The complex stabilities and the thermodynamic data for the complexation of α-cyclodextrin and cucurbit[6]uril with some amino acids (glycine, L-alanine, L-valine, L-phenylalanine, 6-amino hexanoic acid, 8-amino octanoic acid, 11-amino undecanoic acid) and dipeptides (glycyl-glycine, glycyl-L-valine, glycyl-L-leucine and glycyl-L-phenylalanine) have been determined in aqueous solution by calorimetric titrations. The complex formation with α-cyclodextrin is mainly favoured by entropic contributions due to the release of water molecules from the cavity of the ligand. The values of the reaction enthalpies are small with the exception of 11-amino undecanoic acid. In case of the ligand cucurbit[6]uril, ion-dipole interactions between the protonated amino groups of the amino acids and the carbonyl groups take place. By steric reasons these interactions are lowered for native amino acids because the polar carboxylic groups are always located outside the hydrophobic cavity of cucurbit[6]uril. The complexes of both ligands with dipeptides in water are characterised by hydrophobic interactions and in case of cucurbit[6]uril by additional ion-dipole interactions

  3. Does a patient-managed insulin intensification strategy with insulin glargine and insulin glulisine provide similar glycemic control as a physician-managed strategy? Results of the START (Self-Titration With Apidra to Reach Target) Study: a randomized noninferiority trial.

    Science.gov (United States)

    Harris, Stewart B; Yale, Jean-François; Berard, Lori; Stewart, John; Abbaszadeh, Babak; Webster-Bogaert, Susan; Gerstein, Hertzel C

    2014-01-01

    OBJECTIVE Diabetes self-management is universally regarded as a foundation of diabetes care. We determined whether comparable glycemic control could be achieved by self-titration versus physician titration of a once-daily bolus insulin dose in patients with type 2 diabetes who are unable to achieve optimal glycemia control with a basal insulin. RESEARCH DESIGN AND METHODS Patients with type 2 diabetes, an HbA1c level >7% (53 mmol/mol), and either nocturnal hypoglycemia episodes or an insufficient basal insulin glargine level (with or without oral agents) to achieve a fasting plasma glucose level ≤6 mmol/L (108 mg/dL) were studied. Participants all had bolus insulin glulisine added at breakfast and were allocated to either algorithm-guided patient self-titration or physician titration. The primary outcome was an HbA1c level ≤7% (53 mmol/mol) without severe hypoglycemia. RESULTS After a mean (SD) follow-up of 159.4 days (36.2 days), 28.4% of participants in the self-titration arm vs. 21.2% in the physician titration arm achieved an HbA1c level of ≤7% (53 mmol/mol) without severe hypoglycemia (between-group absolute difference 7.2%; 95% CI -3.2 to 17.7). The lower end of this 95% confidence interval was within the predetermined noninferiority boundary of -5% (P noninferiority = 0.011). CONCLUSIONS In stable patients with type 2 diabetes who are receiving doses of basal insulin glargine who require bolus insulin, a simple bolus insulin patient-managed titration algorithm is as effective as a physician-managed algorithm.

  4. Efficacy of daytime continuous positive airway pressure titration in severe obstructive sleep apnoea.

    Science.gov (United States)

    Rudkowski, J C; Verschelden, P; Kimoff, R J

    2001-09-01

    The aim of this study was to evaluate manual nasal continuous positive airway pressure (nCPAP) titration during daytime polysomnography compared with conventional overnight titration for patients with severe obstructive sleep apnoea. Thirty-two patients who underwent daytime titration were retrospectively matched (for age, sex, body mass index and apnoea/hypopnoea index (AHI)) to a group titrated overnight during the same period. Successful titration was defined as the identification of the nCPAP level (effective nCPAP (Peff)) required to eliminate respiratory events during all sleep stages. After 3 months of therapy on nCPAP at Peff, nCPAP utilization history was obtained and a group of patients underwent a repeat polysomnogram (PSG) and completed a follow-up Epworth Sleepiness Scale (ESS) score. Initial titration was successful in 91% of daytime patients and 91% of overnight patients. The success of daytime titration was not related to diagnostic AHI or ESS score. Subjective nCPAP utilization was statistically similar in both groups. On the follow-up PSG, there were no significant differences between daytime (n=11) and overnight (n=11) patients in measures of sleep quality or respiratory disturbance. Both groups demonstrated similar and significant improvements in ESS score. These findings suggest that the effective nasal continuous positive airway pressure can be accurately established during daytime titration in a substantial proportion of severe, symptomatic obstructive sleep apnoea patients.

  5. The predictive value of drug-induced sleep endoscopy for CPAP titration in OSA patients.

    Science.gov (United States)

    Lan, Ming-Chin; Hsu, Yen-Bin; Lan, Ming-Ying; Huang, Yun-Chen; Kao, Ming-Chang; Huang, Tung-Tsun; Chiu, Tsan-Jen; Yang, Mei-Chen

    2017-12-15

    The aim of this study was to identify possible upper airway obstructions causing a higher continuous positive airway pressure (CPAP) titration level, utilizing drug-induced sleep endoscopy (DISE). A total of 76 patients with obstructive sleep apnea (OSA) underwent CPAP titration and DISE. DISE findings were recorded using the VOTE classification system. Polysomnographic (PSG) data, anthropometric variables, and patterns of airway collapse during DISE were analyzed with CPAP titration levels. A significant association was found between the CPAP titration level and BMI, oxygen desaturation index (ODI), apnea-hypopnea index (AHI), and neck circumference (NC) (P CPAP titration level (P CPAP titration level and any other collapse at the tongue base or epiglottis. By analyzing PSG data, anthropometric variables, and DISE results with CPAP titration levels, we can better understand possible mechanisms resulting in a higher CPAP titration level. We believe that the role of DISE can be expanded as a tool to identify the possible anatomical structures that may be corrected by oral appliance therapy or surgical intervention to improve CPAP compliance.

  6. Forced Ignition Study Based On Wavelet Method

    Science.gov (United States)

    Martelli, E.; Valorani, M.; Paolucci, S.; Zikoski, Z.

    2011-05-01

    The control of ignition in a rocket engine is a critical problem for combustion chamber design. Therefore it is essential to fully understand the mechanism of ignition during its earliest stages. In this paper the characteristics of flame kernel formation and initial propagation in a hydrogen-argon-oxygen mixing layer are studied using 2D direct numerical simulations with detailed chemistry and transport properties. The flame kernel is initiated by adding an energy deposition source term in the energy equation. The effect of unsteady strain rate is studied by imposing a 2D turbulence velocity field, which is initialized by means of a synthetic field. An adaptive wavelet method, based on interpolating wavelets is used in this study to solve the compressible reactive Navier- Stokes equations. This method provides an alternative means to refine the computational grid points according to local demands of the physical solution. The present simulations show that in the very early instants the kernel perturbed by the turbulent field is characterized by an increased burning area and a slightly increased rad- ical formation. In addition, the calculations show that the wavelet technique yields a significant reduction in the number of degrees of freedom necessary to achieve a pre- scribed solution accuracy.

  7. SPECIAL CONSIDERATIONS REGARDING WARFARIN DOSE TITRATION IN PATIENTS WITH ATRIAL FIBRILLATION DEPENDING ON CLINICAL FACTORS

    Directory of Open Access Journals (Sweden)

    E. L. Artanova

    2011-01-01

    Full Text Available Aim. To study the relations of clinical characteristics and individual warfarin dose titration in patients with atrial fibrillation. Material and methods. Period of warfarin dose titration was analyzed in 68 patients with atrial fibrillation due to ischemic heart disease. Adjusted warfarin dose in milligram, duration of dose titration in days and maximal international normalized ratio (INR were taken into account. Sex, age, history of myocardial infarction and stroke, concomitant diseases, amiodarone therapy were considered among clinical characteristics. Results. Adjusted warfarin dose was significantly higher in obesity , and it was lower in case of experienced myocardial infarction. The INR highest levels and maximal amplitudes of its fluctuations were observed in patients with thyroid gland nodes and smokers. Period of warfarin dose titration was longer in patients treated with amiodarone. Conclusion. Warfarin dose titration in patients with atrial fibrillation depends on the presence of myocardial infarction, obesity , thyroid nodular changes, smoking and amiodarone treatment.

  8. Molybdenum (6) determination by the method of high-frequency and pH titration

    International Nuclear Information System (INIS)

    Lukianets, I.G.; Kulish, N.G.

    1981-01-01

    A possibility to determine Mo(6) using the method of high frequency and pH-metric titration is investigated. By means of the high frequency contact R-cell Mo(6) titration is performed using different precipitators: 8-oxiquinoline, lead nitrate and acetate and silver nitrate. It is established that the best conditions are achieved during titration of 67.2-1343 mg/10 ml Mo(6) with lead acetate (pH 4.5-6.5). Relative standard deviation Ssub(r) constitutes 0.005 pH-metric titration of Mo(6) with complexone 3 is studied. The range of Mo(6) concentrations determined constitutes 13.43-134.3 mg at pH initial value of 3.5-5.5. Relative standard deviation Ssub(r) constitutes 0.003. Techniques of molybdenum determination in ferromolybdenum using the method of high frequency and pH-metric titration are developed [ru

  9. Electroconvulsive therapy stimulus titration: Not all it seems.

    Science.gov (United States)

    Rosenman, Stephen J

    2018-05-01

    To examine the provenance and implications of seizure threshold titration in electroconvulsive therapy. Titration of seizure threshold has become a virtual standard for electroconvulsive therapy. It is justified as individualisation and optimisation of the balance between efficacy and unwanted effects. Present day threshold estimation is significantly different from the 1960 studies of Cronholm and Ottosson that are its usual justification. The present form of threshold estimation is unstable and too uncertain for valid optimisation or individualisation of dose. Threshold stimulation (lowest dose that produces a seizure) has proven therapeutically ineffective, and the multiples applied to threshold to attain efficacy have never been properly investigated or standardised. The therapeutic outcomes of threshold estimation (or its multiples) have not been separated from simple dose effects. Threshold estimation does not optimise dose due to its own uncertainties and the different short-term and long-term cognitive and memory effects. Potential harms of titration have not been examined. Seizure threshold titration in electroconvulsive therapy is not a proven technique of dose optimisation. It is widely held and practiced; its benefit and harmlessness assumed but unproven. It is a prematurely settled answer to an unsettled question that discourages further enquiry. It is an example of how practices, assumed scientific, enter medicine by obscure paths.

  10. Acid/base titrations of simulated PWR crevice environments

    International Nuclear Information System (INIS)

    Pang, J.; Macdonald, D.D.; Millett, P.J.

    1993-01-01

    The construction and operation of a titration system that is capable of exploring the acid/base properties of aqueous systems at temperatures solution is measured using YSZ sensors of the type Hg/HgO/ZrO 2 (Y 2 O 3 )/Solution in conjunction with a suitable reference electrode. The use of the system for measuring the pH of the titrated solutions (NaOH/H 2 SO 4 ) is discussed, and we show that the YSZ pH sensor is capable of consistent and precise pH measurements at elevated temperature (275-325 degrees C) and pressures (100-150 bars). However, the accuracy of the measured pH depends critically on the performance of the reference electrode. In the present work, we ensure the viability of the reference electrode. In the present work, we ensure the viability of the reference electrode by periodically calibrating it in situ using the pH sensor and a standard solution of known pH versus temperature characteristics. The titration data obtained in this study are compared with predictions from EPRI's MULTEQ code, and are found to be in satisfactory agreement in the alkaline pH region. Observed discrepancies in the acidic pH region between the two sets of data are attributed to corrosion of the alloys used to fabricate the titration system

  11. Dose titration of BAF312 attenuates the initial heart rate reducing effect in healthy subjects.

    Science.gov (United States)

    Legangneux, Eric; Gardin, Anne; Johns, Donald

    2013-03-01

    Previous studies have shown transient decreases in heart rate (HR) following administration of sphingosine 1-phosphate (S1P) receptor modulators including BAF312. This study was conducted to determine whether dose titration of BAF312 reduces or eliminates these effects. Fifty-six healthy subjects were randomized 1:1:1:1 to receive BAF312 in one of two dose titration (DT) regimens (DT1 and DT2: 0.25-10 mg over 9-10 days), no titration (10 mg starting dose) or placebo. Pharmacodynamic and pharmacokinetic parameters were assessed. Neither DT1 nor DT2 resulted in clinically significant bradycardia or atrioventricular conduction effects. Both titration regimens showed a favourable difference on each of days 1-12 vs. the non-titration regimen on day 1 for HR effects (P titration was 1.18 (95% confidence interval [CI] 1.13, 1.23) and 1.14 (95% CI 1.09, 1.18) for DT2 (both P titration HRs showed considerable separation from placebo throughout the study. There was no statistically significant reduction in HR vs. placebo on day 1 in either titration regimen. On days 3-7 subjects in DT1 and DT2 experienced minor reductions in HR vs. placebo (approximately 5 beats min⁻¹; P ≤ 0.0001). From days 9-12, HRs in both titration regimens were comparable with placebo. Both titration regimens effectively attenuated the initial bradyarrhythmia observed on day 1 of treatment with BAF312 10 mg. © 2012 Novartis Institutes for BioMedical Research (NIBIR). British Journal of Clinical Pharmacology © 2012 The British Pharmacological Society.

  12. Rapid Inpatient Titration of Intravenous Treprostinil for Pulmonary Arterial Hypertension: Safe and Tolerable.

    Science.gov (United States)

    El-Kersh, Karim; Ruf, Kathryn M; Smith, J Shaun

    There is no standard protocol for intravenous treprostinil dose escalation. In most cases, slow up-titration is performed in the outpatient setting. However, rapid up-titration in an inpatient setting is an alternative that provides opportunity for aggressive treatment of common side effects experienced during dose escalation. In this study, we describe our experience with inpatient rapid up-titration of intravenous treprostinil. This was a single-center, retrospective study in which we reviewed the data of subjects with pulmonary arterial hypertension treated at our center who underwent inpatient rapid up-titration of intravenous treprostinil. Our treprostinil dose escalation protocol included initiation at 2 ng·kg·min with subsequent up-titration by 1 ng·kg·min every 6 to 8 hours as tolerated by side effects. A total of 16 subjects were identified. Thirteen subjects were treprostinil naive (naive group), and 3 subjects were receiving subcutaneous treprostinil but were hospitalized for further intravenous up-titration of treprostinil dose (nonnaive group). In the naive group, the median maximum dose achieved was 20 ng·kg·min with an interquartile range (IQR) of 20-23 ng·kg·min. The median up-titration interval was 6 days (IQR: 4-9). In the nonnaive group, the median maximum dose achieved was 20 ng·kg·min (range: 17-30). The median up-titration interval was 8.5 days (range: 1.5-11). Overall, the median maximum dose achieved was 20 ng·kg·min (IQR: 20-23.5), and the median up-titration interval was 6 days (IQR: 4.6-9.25), with no reported significant adverse hemodynamic events. In patients with pulmonary arterial hypertension, rapid inpatient titration of intravenous treprostinil is safe and tolerable.

  13. Non-aqueous titration of benzotrifuroxan (BTF)

    Energy Technology Data Exchange (ETDEWEB)

    Selig, W.

    1978-01-01

    This compound can be titrated potentiometrically as an acid with tetrabutylammonium hydroxide in dimethylformamide, dimethylsulfoxide, acetone, pyridine, tetramethylguanidine. The solvent of choice is dimethylformamide which yields the steepest titration curve and the lowest standard deviation. The equivalent weight of benzotrifuroxan is dependent on the solvent used indicating a strong interaction with the solvent. In dimethylformamide, the equivalent weight of benzotrifuroxan is 151.3, corresponding to 1.67 equivalents per mole.

  14. Interaction of Soybean 7S Globulin Peptide with Cell Membrane Model via Isothermal Titration Calorimetry, Quartz Crystal Microbalance with Dissipation, and Langmuir Monolayer Study.

    Science.gov (United States)

    Zou, Yuan; Pan, Runting; Ruan, Qijun; Wan, Zhili; Guo, Jian; Yang, Xiaoquan

    2018-05-16

    To understand the underlying molecular mechanism of the cholesterol-lowering effect of soybean 7S globulins, the interactions of their pepsin-released peptides (7S-peptides) with cell membrane models consisting of dipalmitoylphosphatidylcholine (DPPC), dioleoylphosphatidylcholine (DOPC), and cholesterol (CHOL) were systematically studied. The results showed that 7S-peptides were bound to DPPC/DOPC/CHOL liposomes mainly through van der Waals forces and hydrogen bonds, and the presence of higher CHOL concentrations enhanced the binding affinity (e.g., DPPC/DOPC/CHOL = 1:1:0, binding ratio = 0.114; DPPC/DOPC/CHOL = 1:1:1, binding ratio = 2.02). Compression isotherms indicated that the incorporation of 7S-peptides increased the DPPC/DOPC/CHOL monolayer fluidity and the lipid raft size. The presence of CHOL accelerated the 7S-peptide accumulation on lipid rafts, which could serve as platforms for peptides to develop into β-sheet rich structures. These results allow us to hypothesize that 7S-peptides may indirectly influence membrane protein functions via altering the membrane organization in the enterocytes.

  15. Initial Evaluation of a Titration Appliance for Temporary Treatment of Obstructive Sleep Apnea.

    Science.gov (United States)

    Levendowski, Daniel J; Morgan, Todd; Westbrook, Philip

    2012-01-01

    Custom oral appliances that adjustably advance the mandible provide superior outcomes when treating patients with moderate or severe sleep apnea. Custom appliances, however, are expensive, must be fitted by a dentist, and the likelihood of successful outcomes are difficult to predict. An inexpensive trial appliance, if proven efficacious, might be used to predict custom appliance outcomes or to provide temporary therapeutic benefit. The aim of this initial study was to assess the treatment efficacy of a novel titration oral appliance with that of an optimized custom appliance. Seventeen patients, treated with a custom oral appliance for at least one year, successfully completed a three-night home sleep test. The baseline obstructive sleep apnea severity was established on Night 1 with seven patients exhibiting severe, six moderate and four mild apnea/hypopnea indexes. Patients were randomly assigned to wear their custom appliance or the titration appliance on Nights 2 and 3. Significant reductions in the mean overall and supine apnea indexes (p titration and custom appliances. The proportion of patients who exhibited at least a 50% reduction in the overall apnea index and supine apnea/hypopnea were similar for the titration and custom appliance (~60%). The custom appliance reduced the overall apnea/hypopnea index by 50% in a greater proportion of the patients compared to the titration appliance (77% vs. 53%). The titration appliance significantly reduced the degree of hypoxic exposure across sleep disordered breathing events overall (p titration appliance, but preferred the titration appliance to no therapy. The titration appliance may be useful in assessing oral appliance treatment efficacy. When set to 70% of maximum protrusion, the titration appliance may provide immediate, temporary therapeutic benefit.

  16. Theoretical study of the effect of probe shape on adhesion force between probe and substrate in atomic force microscope experiment

    OpenAIRE

    Yang, Li; Hu, Junhui; Kong, Lingjiang

    2017-01-01

    The quantitative description of adhesion force dependence on the probe shapes are of importance in many scientific and industrial fields. In order to elucidate how the adhesion force varied with the probe shape in atomic force microscope manipulation experiment, we performed a theoretical study of the influences of the probe shape (the sphere and parabolic probe) on the adhesion force at different humidity. We found that the combined action of the triple point and the Kelvin radius guiding th...

  17. Theory of titration curves-VII The properties of derivative titration curves for strong acid-strong base and other isovalent ion-combination titrations.

    Science.gov (United States)

    Meites, T; Meites, L

    1970-06-01

    This paper deals with isovalent ion-combination titrations based on reactions that can be represented by the equation M(n+) + X(n-) --> MX, where the activity of the product MX is invariant throughout a titration, and with the derivative titration curves obtained by plotting d[M(+)]/dfversus f for such titrations. It describes some of the ways in which such curves can be obtained; it compares and contrasts them both with potentiometric titration curves, which resemble them in shape, and with segmented titration curves, from which they are derived; and it discusses their properties in detail.

  18. Coulometric titration at low temperatures-nonstoichiometric silver selenide

    OpenAIRE

    Beck, Gesa K.; Janek, Jürgen

    2003-01-01

    A modified coulometric titration technique is described for the investigation of nonstoichiometric phases at low temperatures. It allows to obtain titration curves at temperatures where the conventional coulometric titration technique fails because of too small chemical diffusion coefficients of the mobile component. This method for indirect coulometric titration is applied to silver selenide between -100 and 100 °C. The titration curves are analyzed on the basis of a defect chemical model an...

  19. Forces exerted by jumping children: A pilot study

    NARCIS (Netherlands)

    Moes, C.C.M.; Bakker, H.E.

    1998-01-01

    This article reports on a pilot study of the loads exerted vertically by children when jumping. The subjects of the study were 17 children, aged from two to twelve years. Measurements were made using video recordings and a force-plate. The influence of the stiffness of the base and of jumping with

  20. An Atomic Force Microscopical Study of the Synaptonemal Complex

    NARCIS (Netherlands)

    Putman, C.A.J.; Putman, C.A.J.; Dietrich, A.J.J.; de Grooth, B.G.; van Marle, J.; Heyting, C.; van Hulst, N.F.; Greve, Jan

    1993-01-01

    The chromosomal structure which is specific for meiosis, the synaptonemal complex (SC), plays a major role in chromosome pairing and the recombination of genetic material. The SC was studied using atomic force microscopy (AFM). The results of this study confirm the results of light and electron

  1. A generalized approach for the calculation and automation of potentiometric titrations Part 2. Redox Titrations

    NARCIS (Netherlands)

    Stur, J.; Bos, M.; van der Linden, W.E.

    1984-01-01

    The very fast calculation procedure described earlier is applied to calculate the titration curves of complicated redox systems. The theory is extended slightly to cover inhomogeneous redox systems. Titrations of iodine or 2,6-dichloroindophenol with ascorbic acid are described. It is shown that

  2. End-point construction and systematic titration error in linear titration curves-complexation reactions

    NARCIS (Netherlands)

    Coenegracht, P.M.J.; Duisenberg, A.J.M.

    The systematic titration error which is introduced by the intersection of tangents to hyperbolic titration curves is discussed. The effects of the apparent (conditional) formation constant, of the concentration of the unknown component and of the ranges used for the end-point construction are

  3. Amperometric titration of thorium and some lanthanoids in acetic-acid medium using two indicator electrodes

    International Nuclear Information System (INIS)

    Khadeev, V.A.; Gevorgyan, A.M.; Talipov, Sh.T.; Kostylev, V.S.

    1979-01-01

    The votammetric behaviour of nitriletrimethylphosphonic acid (NTMP) in the medium of anhydrous acetic acid with different backgrounds in the anode region of polarization of a platinum microdisk electrode, is studied. The optimal conditions are found for the amperometric titration with two indicator electrodes of thorium and same lanthanides by a NTMP solution in anhydrous acetic medium. The influence of foreign anions and cations on the results of titration by the NTPM solution in anhydrous acetic acid is studied. The selectivity of titration in anhydrous medium is higher than in aqueous

  4. Kinetics of bacterial potentiometric titrations: the effect of equilibration time on buffering capacity of Pantoea agglomerans suspensions.

    Science.gov (United States)

    Kapetas, Leon; Ngwenya, Bryne T; Macdonald, Alan M; Elphick, Stephen C

    2011-07-15

    Several recent studies have made use of continuous acid-base titration data to describe the surface chemistry of bacterial cells as a basis for accurately modelling metal adsorption to bacteria and other biomaterials of potential industrial importance. These studies do not share a common protocol; rather they titrate in different pH ranges and they use different stability criteria to define equilibration time during titration. In the present study we investigate the kinetics of bacterial titrations and test the effect they have on the derivation of functional group concentrations and acidity constants. We titrated suspensions of Pantoea agglomerans by varying the equilibration time between successive titrant additions until stability of 0.1 or 0.001 mV s(-1) was attained. We show that under longer equilibration times, titration results are less reproducible and suspensions exhibit marginally higher buffering. Fluorescence images suggest that cell lysis is not responsible for these effects. Rather, high DOC values and titration reversibility hysterisis after long equilibration times suggest that variability in buffering is due to the presence of bacterial exudates, as demonstrated by titrating supernatants separated from suspensions of different equilibration times. It is recommended that an optimal equilibration time is always determined with variable stability control and preliminary reversibility titration experiments. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. Titration and hysteresis in epigenetic chromatin silencing

    International Nuclear Information System (INIS)

    Dayarian, Adel; Sengupta, Anirvan M

    2013-01-01

    Epigenetic mechanisms of silencing via heritable chromatin modifications play a major role in gene regulation and cell fate specification. We consider a model of epigenetic chromatin silencing in budding yeast and study the bifurcation diagram and characterize the bistable and the monostable regimes. The main focus of this paper is to examine how the perturbations altering the activity of histone modifying enzymes affect the epigenetic states. We analyze the implications of having the total number of silencing proteins, given by the sum of proteins bound to the nucleosomes and the ones available in the ambient, to be constant. This constraint couples different regions of chromatin through the shared reservoir of ambient silencing proteins. We show that the response of the system to perturbations depends dramatically on the titration effect caused by the above constraint. In particular, for a certain range of overall abundance of silencing proteins, the hysteresis loop changes qualitatively with certain jump replaced by continuous merger of different states. In addition, we find a nonmonotonic dependence of gene expression on the rate of histone deacetylation activity of Sir2. We discuss how these qualitative predictions of our model could be compared with experimental studies of the yeast system under anti-silencing drugs. (paper)

  6. Optical tweezers force measurements to study parasites chemotaxis

    Science.gov (United States)

    de Thomaz, A. A.; Pozzo, L. Y.; Fontes, A.; Almeida, D. B.; Stahl, C. V.; Santos-Mallet, J. R.; Gomes, S. A. O.; Feder, D.; Ayres, D. C.; Giorgio, S.; Cesar, C. L.

    2009-07-01

    In this work, we propose a methodology to study microorganisms chemotaxis in real time using an Optical Tweezers system. Optical Tweezers allowed real time measurements of the force vectors, strength and direction, of living parasites under chemical or other kinds of gradients. This seems to be the ideal tool to perform observations of taxis response of cells and microorganisms with high sensitivity to capture instantaneous responses to a given stimulus. Forces involved in the movement of unicellular parasites are very small, in the femto-pico-Newton range, about the same order of magnitude of the forces generated in an Optical Tweezers. We applied this methodology to investigate the Leishmania amazonensis (L. amazonensis) and Trypanossoma cruzi (T. cruzi) under distinct situations.

  7. Charge-Transfer Complexes Studied by Dynamic Force Spectroscopy

    Directory of Open Access Journals (Sweden)

    Jurriaan Huskens

    2013-03-01

    Full Text Available In this paper, the strength and kinetics of two charge-transfer complexes, naphthol-methylviologen and pyrene-methylviologen, are studied using dynamic force spectroscopy. The dissociation rates indicate an enhanced stability of the pyrene-methylviologen complex, which agrees with its higher thermodynamic stability compared to naphthol-methylviologen complex.

  8. Use of an Arduino to Study Buoyancy Force

    Science.gov (United States)

    Espindola, P. R.; Cena, C. R.; Alves, D. C. B.; Bozano, D. F.; Goncalves, A. M. B.

    2018-01-01

    The study of buoyancy becomes very interesting when we measure the apparent weight of the body and the liquid vessel weight. In this paper, we propose an experimental apparatus that measures both the forces mentioned before as a function of the depth that a cylinder is sunk into the water. It is done using two load cells connected to an Arduino.…

  9. Dissipation and oscillatory solvation forces in confined liquids studied by small amplitude atomic force spectroscopy

    NARCIS (Netherlands)

    de Beer, Sissi; van den Ende, Henricus T.M.; Mugele, Friedrich

    2010-01-01

    We determine conservative and dissipative tip–sample interaction forces from the amplitude and phase response of acoustically driven atomic force microscope (AFM) cantilevers using a non-polar model fluid (octamethylcyclotetrasiloxane, which displays strong molecular layering) and atomically flat

  10. Persistent benefits of slow titration of paroxetine in a six-month follow-up.

    Science.gov (United States)

    Olgiati, Paolo; Serretti, Alessandro

    2015-09-01

    Paroxetine titration may be difficult in older individuals as they are more sensitive to side effects. The current study extends to 6 months our previously published report in which paroxetine was started at 2.5 mg/day and slowly increased by 2.5 mg on alternate days (slow titration) or rapidly titrated to target dose from 10 mg/day (standard titration) in a naturalistic setting. Here, the follow-up period was extended to 26 weeks. We performed an intent-to-treat analysis of 47 subjects from the original sample (major depressive disorder and/or generalized anxiety disorder (GAD); >60 years of age). Missing evaluations were replaced by last observations carried forward. GAD was included as a stratification factor. Patients in whom paroxetine was slowly up-titrated were more likely to remit (84.0% vs 54.5%; p = 0.028) and had lower core depression (p = 0.0015) and psychic anxiety levels (p = 0.006) after 26 weeks. Dropout rate was 20% in the slow titration group compared with 77.3% in the standard titration arm (p titration groups in the subsample without GAD. Despite some limitations, these findings suggest that paroxetine treatment should be started at lower doses in older depressed patients and slowly up-titrated. This strategy would allow to increase antidepressant response and the likelihood of completing treatment cycle in patients with high anxiety levels and GAD comorbidity. Copyright © 2015 John Wiley & Sons, Ltd.

  11. Monitoring Acid–Base Titrations on Wax Printed Paper Microzones Using a Smartphone

    Directory of Open Access Journals (Sweden)

    Sandro A. Nogueira

    2017-05-01

    Full Text Available This study describes the use of a smartphone for monitoring acid–base titrations on wax printed paper microzones. An array of twelve microzones of 5 mm diameter each was wax printed on filter paper. The analytical performance of the proposed devices was explored with acid–base titrations examples, where jaboticaba peel extract was used as a natural pH indicator. The color intensity was captured using a smartphone and analyzed through a free App named Photometrix®. Before titrations, color intensity versus pH was calibrated to be used as a reference in titrations as (i strong acid versus strong base; (ii strong base versus strong acid; and (iii weak acid versus strong base. In all examples, images were obtained after the addition of each aliquot of titrant solutions. The obtained titration curves showed the same behavior as the conventional titration curves. After evaluating the feasibility of the proposed methodology, the concentration level of acetic acid was obtained in three vinegar samples. Although the obtained values ranged from 5% to 8% compared to the concentrations on the conventional method, the proposed methodology presented high analytical reliability. The calculated concentrations of acetic acid in three samples ranged from 3.87% to 3.93%, and the proposed methodology did not significantly differ from classic acid–base titration at a confidence level of 95%. The acid–base titration on paper-based devices is outstanding, since any titration can be completed within 5 min using 20 µL volumes. Besides, the use of a smartphone to capture images followed by analysis in a free app offers simplicity to all users. The proposed methodology arises as a new strand to be exploited in the diffusion of the analytical chemistry education field as well as an alternative for quantitative analysis with extremely simplified instrumentation.

  12. US/UK Sensor-To-Shooter Multinational C4 Interoperability Study Force-On-Force Effectiveness Methodology

    National Research Council Canada - National Science Library

    Bailey, Timothy J

    2000-01-01

    .... This methodology has been successfully applied to Army, joint, and multinational studies. The latest of these studies, the US/UK Sensor-To-Shooter Multinational C4 Interoperability Study Force-On-Force Analysis, was an effort to measure the value...

  13. An accurate potentiometric titration of 5-25 mg uranium

    International Nuclear Information System (INIS)

    Slanina, J.; Bakker, F.; Lingerak, W.A.

    1976-01-01

    A potentiometric titration of 5 to 25 mg uranium is described. Sulphamic and phosphoric acid are added to the sample (volume 1 ml), U VI is reduced to U IV by Fe 2+ and the excess of Fe 2+ is oxidized by a mixture of nitric acid, sulphamic acid and ammonium molybdate; vanadyl sulphate is added to ensure a sharp end-point of the titration. The resultant U IV is titrated automatically with 0.02500N potassiumdichromate using a platinum indicator electrode. The automatic titration is performed both with a commercial titrator (Mettler) and with an R.C.N. titrator which waits after each addition until the equilibrium is reached. Using the Mettler titrator an accuracy of 0.05% relative was reached. The R.C.N. setpoint titrator gave results with an accuracy of 0.04% relative at the 20-mg U level. Each titration takes 5 to 7 min. (author)

  14. The Lavelle Affair: An Air Force Case Study in Ethics

    Science.gov (United States)

    2016-06-01

    THE LAVELLE AFFAIR: AN AIR FORCE CASE STUDY IN ETHICS BY KRISTINA ELLIS A THESIS PRESENTED TO THE FACULTY OF THE SCHOOL OF... ethical transgressions. As such, the story of General Lavelle’s wartime command experiences became a case study in ethics and integrity within Air...1 1 THE LIFE AND CAREER OF GENERAL LAVELLE 8 1 VIETNAM 14 2 CIVIL-MILITARY RELATIONS 25 2 ETHICAL

  15. Theoretical problems associated with the use of acetic anhydride as a co-solvent for the non-aqueous titration of hydrohalides of organic bases and quaternary ammonium salts.

    Science.gov (United States)

    Völgyi, Gergely; Béni, Szabolcs; Takács-Novák, Krisztina; Görög, Sándor

    2010-01-05

    A potentiometric titration study of organic base hydrohalides and quaternary ammonium salts using perchloric acid as the titrant and a mixture of acetic anhydride and acetic acid as the solvent was carried out and the titration mixture was analysed by NMR in order to clarify the chemistry of the reactions involved. It was found that in contrast to the general belief the formation of acetyl halides and titratable free acetate ion does not take place prior to the titration but NMR spectra proved the formation of acetyl halides in the course of the titration. This observation and the fact that the shape of the titration curves depends on the nature of the hydrohaloic acid bound to the base or of the anion in the quaternary ammonium salts led to the conclusion that the titrating agent is acetyl perchlorate formed in situ during the titration. Equations of the reactions involved in the titration process are shown in the paper.

  16. Isothermal Titration Calorimetry in the Student Laboratory

    Science.gov (United States)

    Wadso, Lars; Li, Yujing; Li, Xi

    2011-01-01

    Isothermal titration calorimetry (ITC) is the measurement of the heat produced by the stepwise addition of one substance to another. It is a common experimental technique, for example, in pharmaceutical science, to measure equilibrium constants and reaction enthalpies. We describe a stirring device and an injection pump that can be used with a…

  17. Titration Calculations with Computer Algebra Software

    Science.gov (United States)

    Lachance, Russ; Biaglow, Andrew

    2012-01-01

    This article examines the symbolic algebraic solution of the titration equations for a diprotic acid, as obtained using "Mathematica," "Maple," and "Mathcad." The equilibrium and conservation equations are solved symbolically by the programs to eliminate the approximations that normally would be performed by the student. Of the three programs,…

  18. NBL-Davies-Gray weight titration method

    International Nuclear Information System (INIS)

    Hassell, C.

    1981-01-01

    The titration method for uranium consists of the following basic steps: reduction of U +6 to U +4 by Fe +2 ; selective oxidation of excess Fe +2 by HNO 3 with Mo +6 catalyst, all in strong phosphoric acid solution; and titration of the U +4 with standard dichromate after dilution. In this paper, detailed procedure of the NBL method, its modification to a gravimetric system or weight titration technique, and miniaturization of the NBL titrimetric method are discussed. Improved precisions and accuracy (2 to 3 times), of the gravimetric titrant delivery has made it possible to reduce the amount of uranium taken for each analysis. At present, using gravimetric delivery, most samples are titrated in the 30 to 50 mg range. Improved precision has led to investigating the possibility of a scaled-down version of the basic method so as to reduce the volume of phosphoric acid waste generated. Because all reactions are carried out in the same vessel, this method can be automated. Analysts at NBL have been able to restrict error to 0.05% or better in the 30 to 100 mg range using the basic procedure

  19. Acid Rain Analysis by Standard Addition Titration.

    Science.gov (United States)

    Ophardt, Charles E.

    1985-01-01

    The standard addition titration is a precise and rapid method for the determination of the acidity in rain or snow samples. The method requires use of a standard buret, a pH meter, and Gran's plot to determine the equivalence point. Experimental procedures used and typical results obtained are presented. (JN)

  20. A rapid method for titration of ascovirus infectivity.

    Science.gov (United States)

    Han, Ningning; Chen, Zishu; Wan, Hu; Huang, Guohua; Li, Jianhong; Jin, Byung Rae

    2018-05-01

    Ascoviruses are a recently described family and the traditional plaque assay and end-point PCR assay have been used for their titration. However, these two methods are time-consuming and inaccurate to titrate ascoviruses. In the present study, a quick method for the determination of the titer of ascovirus stocks was developed based on ascovirus-induced apoptosis in infected insect cells. Briefly, cells infected with serial dilutions of virus (10 -2 -10 -10 ) for 24 h were stained with trypan blue. The stained cells were counted, and the percentage of nonviable cells was calculated. The stained cell rate was compared between virus-infected and control cells. The minimum-dilution group that had a significant difference compared with control and the maximum-dilution group that had no significant difference were selected and then compared each well of the two groups with the average stained cell rate of control. The well was marked as positive well if the stained cell rate was higher than the average stained cell rate of control wells; otherwise, the well was marked as negative wells. The percentage of positive wells were calculated according to the number of positive. Subsequently, the virus titer was calculated through the method of Reed and Muench. This novel method is rapid, simple, reproducible, accurate, and less material-consuming and eliminates the subjectivity of the other procedures for titrating ascoviruses. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Interaction of molybdenum (6) with potassium benzyldithiocarbaminate during amperometric titration

    International Nuclear Information System (INIS)

    Galushko, S.V.; Usatenko, Yu.I.

    1975-01-01

    The paper is an amperometric study of the mechanism of interaction between molybdenum (VI) and potassium benzyl dithiocarbamate [BDTC] which was based on the use of voltamperometry, electron paramagnetic resonance, infrared spectroscopy, potentiometry and elemental analysis. In amperometric titration Mo(VI) with BDTC (pH 4-2) forms a red compound of low solubility. In more acidic media the intensity of coloration is increased and a violet hue develops. On the basis of the data obtained it is concluded that in the amperometric titration of Mo(VI) with potassium BDTC there is first formation of a Mo(VI) compound, which subsequently acquires a red colour as a result of the reduction of Mo(VI) to Mo(V). It was also established that the degree of reduction is small where titration is carried out in the range pH 4.8-0.1. Quantitative determination of Mo is performed most effectively in slightly acidic media. Mo reacts with potassium BDTC in a ratio of 1:2. (E.P.)

  2. A new titration system of a novel split-type superconducting magnet NMR spectrometer.

    Science.gov (United States)

    Kitagawa, Isao; Tanaka, Hideki; Okada, Michiya; Kitaguchi, Hitoshi; Kohzuma, Takamitsu

    2008-12-01

    A new titration system for studying protein-ligand interactions has been developed. In this system, the sample solution is circulated in the route formed by an access path in a split superconducting magnet to maintain a constant protein concentration during the titration experiments. A concentration-control procedure for the ligand/protein ratio is devised, and the ligand/protein ratio is well controlled by this apparatus.

  3. The Adriatic response to the bora forcing. A numerical study

    International Nuclear Information System (INIS)

    Rachev, N.

    2001-01-01

    This paper deals with the bora wind effect on the Adriatic Sea circulation as simulated by a 3-D numerical code (the DieCAST model). The main result of this forcing is the formation of intense upwelling along the eastern coast in agreement with previous theoretical studies and observations. Different numerical experiments are discussed for various boundary and initial conditions to evaluate their influence on both circulation and upwelling patterns

  4. A Climatological Study of Hurricane Force Extratropical Cyclones

    OpenAIRE

    Laiyemo, Razaak O.

    2012-01-01

    Using data compiled by the National Weather Service Ocean Prediction Center, a hurricane force extratropical cyclone climatology is created for three cold seasons. Using the criteria of Sanders and Gyakum (1980), it is found that 75% of the 259 storms explosively deepened. The frequency maximum in the Atlantic basin is located to the southeast of Greenland. In the Pacific, two maxima to the east of Japan are identified. These results are in good agreement with previous studies, despite differ...

  5. A numerical study of microparticle acoustophoresis driven by acoustic radiation forces and streaming-induced drag forces

    DEFF Research Database (Denmark)

    Muller, Peter Barkholt; Barnkob, Rune; Jensen, Mads Jakob Herring

    2012-01-01

    We present a numerical study of the transient acoustophoretic motion of microparticles suspended in a liquid-filled microchannel and driven by the acoustic forces arising from an imposed standing ultrasound wave: the acoustic radiation force from the scattering of sound waves on the particles...

  6. An Olfactory Indicator for Acid-Base Titrations.

    Science.gov (United States)

    Flair, Mark N.; Setzer, William N.

    1990-01-01

    The use of an olfactory acid-base indicator in titrations for visually impaired students is discussed. Potential olfactory indicators include eugenol, thymol, vanillin, and thiophenol. Titrations performed with each indicator with eugenol proved to be successful. (KR)

  7. Potentiometric titration curves of aluminium salt solutions and its ...

    African Journals Online (AJOL)

    Potentiometric titration curves of aluminium salt solutions and its species conversion ... of aluminium salt solutions under the moderate slow rate of base injection. ... silicate radical, and organic acid radical on the titration curves and its critical ...

  8. Antiepileptic Drug Titration and Related Health Care Resource Use and Costs.

    Science.gov (United States)

    Fishman, Jesse; Kalilani, Linda; Song, Yan; Swallow, Elyse; Wild, Imane

    2018-02-27

    Unexpected breakthrough seizures resulting from suboptimal antiepileptic drug (AED) dosing during the titration period, as well as adverse events resulting from rapid AED titration, may influence the titration schedule and significantly increase health care resource use (HRU) and health care costs. To assess the relationship between AEDs, HRU, and costs during AED titration and maintenance. Practicing neurologists were recruited from a nationwide panel to provide up to 3 patient records each for this retrospective medical chart review. Patients with epilepsy who were aged ≥ 18 years and had initiated an AED between January 1, 2014, and January 1, 2016, were followed for 6 months from AED initiation. Titration duration was the time from AED initiation to the beginning of treatment maintenance as determined by the physician. Outcomes were epilepsy-specific HRU (hospitalizations, emergency department visits, outpatient visits, physician referral, laboratory testing/diagnostic imaging, and phone calls) and related costs that occurred during the titration or maintenance treatment periods. Of 811 patients, 156, 128, 125, 120, 114, 107, and 61 initiated the following AEDs: levetiracetam, lamotrigine, lacosamide, valproate, topiramate, carbamazepine, and phenytoin, respectively. Most patients (619/803 [77.1%] with complete AED data) received monotherapy. Baseline characteristics were similar across AEDs (mean [SD] age, 36.6 [14.4] years; 59.0% male). Kaplan-Meier estimates of titration duration ranged from 3.3 weeks (phenytoin) to 8.1 weeks (lamotrigine). From titration to maintenance, the overall incidence of HRU per person-month decreased 54.5%-89.3% for each HRU measure except outpatient visits (24.6% decrease). Total epilepsy-related costs decreased from $80.48 to $42.77 per person-month, or 46.9% from titration to maintenance. AED titration periods had higher HRU rates and costs than AED maintenance, suggesting that use of AEDs with shorter titration requirements

  9. Comparison of VFA titration procedures used for monitoring the biogas process.

    Science.gov (United States)

    Lützhøft, Hans-Christian Holten; Boe, Kanokwan; Fang, Cheng; Angelidaki, Irini

    2014-05-01

    Titrimetric determination of volatile fatty acids (VFAs) contents is a common way to monitor a biogas process. However, digested manure from co-digestion biogas plants has a complex matrix with high concentrations of interfering components, resulting in varying results when using different titration procedures. Currently, no standardized procedure is used and it is therefore difficult to compare the performance among plants. The aim of this study was to evaluate four titration procedures (for determination of VFA-levels of digested manure samples) and compare results with gas chromatographic (GC) analysis. Two of the procedures are commonly used in biogas plants and two are discussed in literature. The results showed that the optimal titration results were obtained when 40 mL of four times diluted digested manure was gently stirred (200 rpm). Results from samples with different VFA concentrations (1-11 g/L) showed linear correlation between titration results and GC measurements. However, determination of VFA by titration generally overestimated the VFA contents compared with GC measurements when samples had low VFA concentrations, i.e. around 1 g/L. The accuracy of titration increased when samples had high VFA concentrations, i.e. around 5 g/L. It was further found that the studied ionisable interfering components had lowest effect on titration when the sample had high VFA concentration. In contrast, bicarbonate, phosphate and lactate had significant effect on titration accuracy at low VFA concentration. An extended 5-point titration procedure with pH correction was best to handle interferences from bicarbonate, phosphate and lactate at low VFA concentrations. Contrary, the simplest titration procedure with only two pH end-points showed the highest accuracy among all titration procedures at high VFA concentrations. All in all, if the composition of the digested manure sample is not known, the procedure with only two pH end-points should be the procedure of

  10. Ion-selective electrodes in potentiometric titrations; a new method for processing and evaluating titration data.

    Science.gov (United States)

    Granholm, Kim; Sokalski, Tomasz; Lewenstam, Andrzej; Ivaska, Ari

    2015-08-12

    A new method to convert the potential of an ion-selective electrode to concentration or activity in potentiometric titration is proposed. The advantage of this method is that the electrode standard potential and the slope of the calibration curve do not have to be known. Instead two activities on the titration curve have to be estimated e.g. the starting activity before the titration begins and the activity at the end of the titration in the presence of large excess of titrant. This new method is beneficial when the analyte is in a complexed matrix or in a harsh environment which affects the properties of the electrode and the traditional calibration procedure with standard solutions cannot be used. The new method was implemented both in a method of linearization based on the Grans's plot and in determination of the stability constant of a complex and the concentration of the complexing ligand in the sample. The new method gave accurate results when using titrations data from experiments with samples of known composition and with real industrial harsh black liquor sample. A complexometric titration model was also developed. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Ovarian and uterine alterations following forced swimming: An immunohistochemical study.

    Science.gov (United States)

    Seyed Saadat, Seyedeh Nazanin; Mohammadghasemi, Fahimeh; Ebrahimi, Hannan; Rafati Sajedi, Hanieh; Chatrnour, Gelayol

    2016-10-01

    Physical exercise is known to be a stressor stimulus that leads to reproductive disruption. The aim of this study was to evaluate the effect of forced swimming on the uterus and ovaries in mice. Adult mice (N=24) were divided into the following three groups: A, control; B, swimming in water (10 o C); and C, swimming in water (23 o C). Swimmers swam for 5 min daily for 5 consecutive days/ wk during 2 wks. An enzyme linked immunosorbent assay was used to determine serum estradiol, follicle stimulating hormone (FSH) and testosterone levels. Immunohistochemistry was performed to study apoptotic cells or estrogen receptor (ER) expression in uterine epithelial cells and ovaries. ANOVA was used for statistical analysis. Swimming in both groups reduced the serum FSH and estradiol levels (pForced swimming of 2 wks duration reduces the serum levels of FSH and estradiol without having effects on apoptosis in the ovaries or uteri of mice. Over a long period of time, forced swimming may have an adverse effect on fertility.

  12. Local adhesive surface properties studied by force microscopy

    International Nuclear Information System (INIS)

    Lekka, M.; Lekki, J.; Marszalek, M.; Stachura, Z.; Cleff, B.

    1998-01-01

    Scanning force microscopy was used in the contact mode to determine the adhesion force between a mica surface and a silicon nitride tip. The measurements were performed in an aqueous solution of sodium and calcium chlorides. The adhesion force according to the Derjaguin-Landau-Verwey-Overbeek theory depends on the competition between two kinds of forces: van der Waals and electrostatic 'double layer'. Two different curves of adhesion force versus salt concentration were obtained from the experiment with monovalent and divalent ions. The tip-surface adhesion force was determined from a statistical analysis of data obtained from the force vs. distance retracting curves. (author)

  13. Potentiometric determination of milligram amounts of uranium by semiautomatic titrator

    International Nuclear Information System (INIS)

    Ryzhinskij, M.V.; Stepanov, A.V.; Preobrazhenskaya, L.D.; Solntseva, L.F.; Gromova, E.A.

    1978-01-01

    A semiautomatic titrator is described which allows gravimetriotentiometricc-p titrat mg amounts of substances. Milligram amounts of uranium (absolute contents and oxygen/uranium ratio) in U 3 O 8 were determined as an example of the titrator action. The relative standard deviation was less than 0.001

  14. Simple and Automated Coulometric Titration of Acid Using Nonisolated Electrodes

    Science.gov (United States)

    Kuntzleman, Thomas S.; Kenney, Joshua B.; Hasbrouck, Scott; Collins, Michael J.; Amend, John R.

    2011-01-01

    Coulometric titrations involve the quantification of analyte by measurements of current and time. In most coulometric titrations, the anode and cathode are placed in isolated cells that are connected by a salt bridge. By contrast, the experiments described here involve coulometric titrations (of acidic protons in solution) using a silver anode and…

  15. PRELIMINARY STUDIES OF RIVETED JOINTS AT FEED FORCE

    Directory of Open Access Journals (Sweden)

    Radosław Bielawski

    2015-08-01

    Full Text Available The aim of the study was to determine the feasibility of riveted joints in composites materials. Static tensile test method was used. In the test one type of glass fabric was used (Interglas 92140 from which two types of composite samples were prepared. In each sample the same type of fiber with the same fiber orientation – 3 layers - was used. The samples had dimensions of 100×100 mm and thickness of approximately 1 mm. The composite probes were located in a metal frame with a screw connection which was made of screws with nominal thread pitch M5. Screws were tightened with constant torque. It was to provide an axial force to the sample during the tensile test. The frame was placed between cross-bars of tensile machine INSTRON 8516. The samples were stretched at a speed of 0.05 mm/s at a distance up to 16 mm. During the tensile test displacement of the samples and pull force were registered. Depending on the fibre orientations and the value of feed force, damage models were described. On the basis of the results the possibility of usage of aluminium rivet nuts connections in composite materials was determined.

  16. Assessment of two theoretical methods to estimate potentiometric titration curves of peptides: comparison with experiment.

    Science.gov (United States)

    Makowska, Joanna; Bagiñska, Katarzyna; Makowski, Mariusz; Jagielska, Anna; Liwo, Adam; Kasprzykowski, Franciszek; Chmurzyñski, Lech; Scheraga, Harold A

    2006-03-09

    We compared the ability of two theoretical methods of pH-dependent conformational calculations to reproduce experimental potentiometric titration curves of two models of peptides: Ac-K5-NHMe in 95% methanol (MeOH)/5% water mixture and Ac-XX(A)7OO-NH2 (XAO) (where X is diaminobutyric acid, A is alanine, and O is ornithine) in water, methanol (MeOH), and dimethyl sulfoxide (DMSO), respectively. The titration curve of the former was taken from the literature, and the curve of the latter was determined in this work. The first theoretical method involves a conformational search using the electrostatically driven Monte Carlo (EDMC) method with a low-cost energy function (ECEPP/3 plus the SRFOPT surface-solvation model, assumming that all titratable groups are uncharged) and subsequent reevaluation of the free energy at a given pH with the Poisson-Boltzmann equation, considering variable protonation states. In the second procedure, molecular dynamics (MD) simulations are run with the AMBER force field and the generalized Born model of electrostatic solvation, and the protonation states are sampled during constant-pH MD runs. In all three solvents, the first pKa of XAO is strongly downshifted compared to the value for the reference compounds (ethylamine and propylamine, respectively); the water and methanol curves have one, and the DMSO curve has two jumps characteristic of remarkable differences in the dissociation constants of acidic groups. The predicted titration curves of Ac-K5-NHMe are in good agreement with the experimental ones; better agreement is achieved with the MD-based method. The titration curves of XAO in methanol and DMSO, calculated using the MD-based approach, trace the shape of the experimental curves, reproducing the pH jump, while those calculated with the EDMC-based approach and the titration curve in water calculated using the MD-based approach have smooth shapes characteristic of the titration of weak multifunctional acids with small differences

  17. Air Force Nuclear Enterprise Organization: A Case Study

    Science.gov (United States)

    2016-09-15

    changes. To address the objectives of this study, five investigative questions ( IQ ) are posed: IQ1. What constitutes the Air Force Nuclear Enterprise...are an effective tool being used to raise the level of training. But it is not only necessary to move away from training that merely checks a box...down to an authoritative brain trust of just a few pertinent players (e.g. AFGSC/CC, HAF/A10 Director, AFNWC/CC, etc). As this study has portrayed

  18. Investigation of iodine liberation process in redox titration of potassium iodate with sodium thiosulfate

    Energy Technology Data Exchange (ETDEWEB)

    Asakai, Toshiaki, E-mail: t-asakai@aist.go.jp [National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba Central 3-9, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8563 (Japan); Hioki, Akiharu [National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba Central 3-9, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8563 (Japan)

    2011-03-09

    Potassium iodate is often used as a reference material to standardize a sodium thiosulfate solution which is a familiar titrant for redox titrations. In the standardization, iodine (triiodide) liberated by potassium iodate in an acidic potassium iodide solution is titrated with a sodium thiosulfate solution. The iodine liberation process is significantly affected by the amount of acid, that of potassium iodide added, the waiting time for the liberation, and light; therefore, the process plays a key role for the accuracy of the titration results. Constant-voltage biamperometry with a modified dual platinum-chip electrode was utilized to monitor the amount of liberated iodine under several liberation conditions. Coulometric titration was utilized to determine the concentration of a sodium thiosulfate solution on an absolute basis. Potassium iodate was assayed by gravimetric titration with the sodium thiosulfate solution under several iodine liberation conditions. The liberation process was discussed from the changes in the apparent assay of potassium iodate. The information of the appropriate titration procedure obtained in the present study is useful for any analysts utilizing potassium iodate to standardize a thiosulfate solution.

  19. Home blood pressure monitoring and self-titration of antihypertensive medications: Proposed patient selection criteria.

    Science.gov (United States)

    Hill, James R

    2016-05-01

    Recent studies have demonstrated that home blood pressure monitoring (HBPM), coupled with self-titration of medications is a viable intervention to control hypertension. There are currently no established criteria to evaluate patients for inclusion in such a program. The purpose of this discussion is to propose criteria for determining if a patient is appropriate to participate in a program of HBPM and self-titration. Inclusion criteria for two self-titration trials were examined, and additional factors in clinical practice were identified and discussed. Additional selection criteria were proposed to support the decision to enroll a patient in an antihypertensive self-titration program. Inclusion criteria from self-titration trials provide a reasonable starting point for choosing appropriate patients in clinical practice, but additional research is necessary. Adaptation of these criteria and consideration of the identified factors can be used to develop decision support instruments. Such instruments should be evaluated for effectiveness and reliability prior to use in clinical practice. HBPM combined with self-titration is an effective patient-centered approach for hypertension management. Decision support instruments to determine appropriate patients are necessary for safe and effective use in clinical practice. ©2015 American Association of Nurse Practitioners.

  20. Investigation of iodine liberation process in redox titration of potassium iodate with sodium thiosulfate

    International Nuclear Information System (INIS)

    Asakai, Toshiaki; Hioki, Akiharu

    2011-01-01

    Potassium iodate is often used as a reference material to standardize a sodium thiosulfate solution which is a familiar titrant for redox titrations. In the standardization, iodine (triiodide) liberated by potassium iodate in an acidic potassium iodide solution is titrated with a sodium thiosulfate solution. The iodine liberation process is significantly affected by the amount of acid, that of potassium iodide added, the waiting time for the liberation, and light; therefore, the process plays a key role for the accuracy of the titration results. Constant-voltage biamperometry with a modified dual platinum-chip electrode was utilized to monitor the amount of liberated iodine under several liberation conditions. Coulometric titration was utilized to determine the concentration of a sodium thiosulfate solution on an absolute basis. Potassium iodate was assayed by gravimetric titration with the sodium thiosulfate solution under several iodine liberation conditions. The liberation process was discussed from the changes in the apparent assay of potassium iodate. The information of the appropriate titration procedure obtained in the present study is useful for any analysts utilizing potassium iodate to standardize a thiosulfate solution.

  1. Graphical evaluation of complexometric titration curves.

    Science.gov (United States)

    Guinon, J L

    1985-04-01

    A graphical method, based on logarithmic concentration diagrams, for construction, without any calculations, of complexometric titration curves is examined. The titration curves obtained for different kinds of unidentate, bidentate and quadridentate ligands clearly show why only chelating ligands are usually used in titrimetric analysis. The method has also been applied to two practical cases where unidentate ligands are used: (a) the complexometric determination of mercury(II) with halides and (b) the determination of cyanide with silver, which involves both a complexation and a precipitation system; for this purpose construction of the diagrams for the HgCl(2)/HgCl(+)/Hg(2+) and Ag(CN)(2)(-)/AgCN/CN(-) systems is considered in detail.

  2. Coulometrische titration von hypochloriten und chloraten.

    Science.gov (United States)

    Gründler, P; Holzapfel, H

    1970-03-01

    Hypochlorite was determined by direct coulometric titration with iron(II) in an acetate buffered solution. Chlorate was titrated with titanium(III) in 2M hydrochloric acid. Amperometric indication with one and two electrodes, respectively, was used. Mixtures of hypochlorites and chlorates, e.g., in industrial electrolytes, may be analysed. On a déterminé l'hypochlorite par titrage coulométrique direct avec le fer(II) dans une solution tamponnée à l'acétate. On a titré le chlorate avec le titane(III) en acide chlorhydrique 2M. On a utilisé l'indication ampérométrique une et deux électrodes respectivement. On peut analyser des mélanges d'hypochlorites et de chlorates, par exemple dans des électrolytes industriels.

  3. Determining a Solubility Product Constant by Potentiometric Titration to Increase Students' Conceptual Understanding of Potentiometry and Titrations

    Science.gov (United States)

    Grabowski, Lauren E.; Goode, Scott R.

    2017-01-01

    Potentiometric titrations are widely taught in first-year undergraduate courses to connect electrochemistry, stoichiometry, and equilibria and to reinforce acid-base titrations. Students perform a potentiometric titration that is then analyzed to determine analyte concentrations and the solubility product constant of the solid species.

  4. Spectrophotometric titration of zirconium in siliceous materials

    International Nuclear Information System (INIS)

    Sugawara, K.F.; Su, Y.-S.; Strzegowski, W.R.

    1978-01-01

    An accurate and selective complexometric titration procedure based upon a spectrophotometrically detected end-point has been developed for the determination of zirconium in glasses, glass-ceramics and refractories. A p-bromomandelic acid separation step for zirconium imparts excellent selectivity to the procedure. The method is particularly important for the 1 to 5% concentration range where a simple, accurate and selective method for the determination of zirconium has been lacking. (author)

  5. Thermometric titration of acids in pyridine.

    Science.gov (United States)

    Vidal, R; Mukherjee, L M

    1974-04-01

    Thermometric titration of HClO(4), HI, HNO(3), HBr, picric acid o-nitrobenzoic acid, 2,4- and 2,5-dinitrophenol, acetic acid and benzoic acid have been attempted in pyridine as solvent, using 1,3-diphenylguanidine as the base. Except in the case of 2,5-dinitrophenol, acetic acid and benzoic acid, the results are, in general, reasonably satisfactory. The approximate molar heats of neutralization have been calculated.

  6. Determination of milligram amounts of neptunium by potentiometric titration

    International Nuclear Information System (INIS)

    Ryzhinskij, M.V.; Solntseva, L.F.

    1981-01-01

    Two procedures of potentiometric titration of about 1 mg Np are reported which are based on its oxidation to neptunium (6) with silver (2) oxide followed by titration with iron (2) to neptunium (5) in one case and to neptunium (4) in the alternative one. The error is not greater than 0.2% rel. Ten-fold uranium excess does not interfere. Up to 1% of plutonium relative to neptunium does not interfere in the case of the titration to neptunium (5). In the titration to neptunium (4), plutonium is titrated stoichiometrically [ru

  7. Studies of heat transport to forced-flow He II

    International Nuclear Information System (INIS)

    Dresner, L.; Kashani, A.; Van Sciver, S.W.

    1985-01-01

    Analytical and experimental studies of heat transport to forced-flow He II are reported. The work is pertinent to the transfer of He II in space. An analytical model has been developed that establishes a condition for two-phase flow to occur in the transfer line. This condition sets an allowable limit to the heat leak into the transfer line. Experimental measurements of pressure drop and flow meter performances indicate that turbulent He II can be analyzed in terms of classical pressure drop correlations

  8. Use of an Arduino to study buoyancy force

    Science.gov (United States)

    Espindola, P. R.; Cena, C. R.; Alves, D. C. B.; Bozano, D. F.; Goncalves, A. M. B.

    2018-05-01

    The study of buoyancy becomes very interesting when we measure the apparent weight of the body and the liquid vessel weight. In this paper, we propose an experimental apparatus that measures both the forces mentioned before as a function of the depth that a cylinder is sunk into the water. It is done using two load cells connected to an Arduino. With this experiment, the student can verify Archimedes’ principle, Newton’s third law, and calculate the density of a liquid. This apparatus can be used in fluid physics laboratories as a substitute for very expensive sensor kits or even to improve too simple approaches, usually employed, but still at low cost.

  9. A new sensor for thermometric titrations.

    Science.gov (United States)

    Najib, Fadhil M; Zewar, Sardir; Abdulla, Ahmad M

    2007-01-15

    A new thermometric sensor, which is a transistor (OC71), has been introduced to follow thermometric titrations successfully to clear end points. The sensor was suitable in both normal and differential modes of titration. It is possible to titrate down to 1.32micromol of HCl and 26.4micromol of H(3)BO(3)in a final 20ml solution with accuracy and precision of 1%, 2.2% and 1.4%, 2.2%, respectively. The sensor, in association with a pH glass electrode, was used for the determination of pK values of some well established weak acids such as, acetic acid (4.77), phosphoric acid (pK(1)=2.18, pK(2)=7.20 and pK(3)=12.32) as well as for a very weak acid of uncertain pK values H(3)BO(3) (pK(1)=9.20, pK(2)=12.7 and pK(3)=13.80). The sensor was also examined for kinetic catalytic determination of iron(III) in water, milk and pharmaceuticals.

  10. Photometric micro-determination of scandium and lanthanides by direct and successive titration using semi-xylenol orange

    International Nuclear Information System (INIS)

    Hafez, M.A.E.H.; Eman, M.E.S.M.

    1986-01-01

    The precision and accuracy attainable in direct titrations of the Sc 3+ , La 3+ or Er 3+ ion with a 0.001 M solution of the disodium salt of EDTA using semi-xylenol orange (SXO) as a metallochromic indicator were studied. Accurate results can be achieved by successive titration. The Sc 3+ ion is titrated at pH 2.4, the pH is adjusted to 5.6-5.9 by adding hexamethylenetetramine buffer solution and the La 3+ ion (or Er 3+ ion) is then titrated. A comparison of SXO and xylenol orange indicators for the successive titration of the Sc 3+ ion and lanthanum or erbium was carried out. (author)

  11. Titration of thorium and rare earths with ethylenediaminetetraacetic acid using semimethylthymol blue by visual end-point indication

    International Nuclear Information System (INIS)

    Hafez, M.A.H.; Kenawy, I.M.M.; Ramadan, M.A.M.

    1994-01-01

    The precision and accuracy attainable in direct complexometric titrations of Thsup(4+) consecutively with either lighter (La 3+ , Nd 3+ , Sm 3+ , Eu 3+ or Gd 3+ ) or heavier lanthanides (Dy 3+ ) in different proportions using Semimethylthymol Blue (SMTB) as a metallochromic indicator and disodium dihydrogen ethylenediaminetetraacetate were studied. Thorium (IV) was titrated at pH 2, the Ph was adjusted to 5.5-6.0 by adding hexamethylenetetramine (hexamine) buffer and acetylacetone-acetone solution and La 3+ (or Nd 3+ , Sm 3+ , Eu 3+ , Gd 3+ or Dy 3+ ) was then titrated. A comparison of the indicators SMTB and Methylthymol Blue (MTB) for successive titrations of Th 4+ and any of the rare earth ions was carried out. The proposed titration method was applied successfully to some naturally occurring ores and minerals containing thorium and some lanthanides and the results were satisfactory. (Author)

  12. An open-label, dose-titration tolerability study of atomoxetine hydrochloride in Japanese adults with attention-deficit/hyperactivity disorder.

    Science.gov (United States)

    Takahashi, Michihiro; Takita, Yasushi; Goto, Taro; Ichikawa, Hironobu; Saito, Kazuhiko; Matsumoto, Hideo; Tanaka, Yasuo

    2011-02-01

    The main purpose of this first atomoxetine study in Japanese adults with attention-deficit/hyperactivity disorder (ADHD) was to investigate the tolerability of an 8-week treatment regimen. This was an open-label, dose escalation study conducted in 45 Japanese patients aged at least 18 years with DSM-IV-defined ADHD. Patients received atomoxetine orally for 8 weeks. Atomoxetine administration was started at 40 mg/day (7 days), and subsequently increased to a maximum dose of 120 mg/day. Tolerability was assessed by discontinuation rate due to adverse events. Adverse events, laboratory tests, vital signs and electrocardiograms were collected. In addition, ADHD symptoms were assessed by using the Japanese version of the Conners' Adult ADHD Rating Scale-Investigator Rated: Screening Version (CAARS-Inv:SV) scores. Thirty-nine patients completed the study period. Atomoxetine was well tolerated with a 6.7% (3/45) discontinuation rate due to nausea, malaise and anorexia. The most commonly reported adverse events were nausea, nasopharyngitis and headache; there were no unexpected safety concerns. No deaths or serious adverse events were reported. Mean CAARS-Inv:SV-J total ADHD symptom scores decreased in a time-dependent manner; the mean change from baseline to endpoint was -15.0 (Patomoxetine was well tolerated in these patients and suggested that atomoxetine at a maximum dose of 120 mg/day would be safe in Japanese ADHD patients. © 2011 The Authors. Psychiatry and Clinical Neurosciences © 2011 Japanese Society of Psychiatry and Neurology.

  13. Open-label, dose-titration tolerability study of atomoxetine hydrochloride in Korean, Chinese, and Taiwanese adults with attention-deficit/hyperactivity disorder.

    Science.gov (United States)

    Takahashi, Michihiro; Goto, Taro; Takita, Yasushi; Chung, Sang-Keun; Wang, Yufeng; Gau, Susan Shur-Fen

    2014-03-01

    The primary objective of this study was to assess the overall safety and tolerability of atomoxetine in Korean, Chinese, and Taiwanese adults with attention-deficit/hyperactivity disorder (ADHD). A total of 44 patients aged ≥18 years who met the Conners' Adult ADHD Diagnostic Interview for DSM-IV diagnostic criteria for ADHD were enrolled from China, Korea, and Taiwan. In this open-label, dose-escalation study, patients received atomoxetine orally once daily over a period of eight weeks, starting at 40 mg/day (one week) up to a maximum dosage of 120 mg/day. Tolerability was evaluated by rate of discontinuation due to adverse events. Safety was assessed by recording all adverse events, laboratory tests, vital signs, and electrocardiograms. ADHD symptoms were evaluated by the Conners' Adult ADHD Rating Scale-Investigator Rated: Screening Version (CAARS-Inv:SV) for efficacy assessment. Thirty-four patients (77.3%) completed the study. Atomoxetine was well tolerated with a discontinuation rate of 2.3% (1/44) due to adverse events. The most commonly reported adverse events were nausea, dizziness, and somnolence. The mean change from baseline to endpoint in CAARS-Inv:SV total ADHD symptom score was -12.5 (P atomoxetine clinical trial in adult patients with ADHD in China, Korea, and Taiwan. Atomoxetine was well tolerated in doses of up to 120 mg/day with no unknown safety concerns. Copyright © 2012 Blackwell Publishing Asia Pty Ltd.

  14. Study of Atmospheric Forcing and Responses (SAFAR campaign: overview

    Directory of Open Access Journals (Sweden)

    A. Jayaraman

    2010-01-01

    Full Text Available Study of Atmospheric Forcing and Responses (SAFAR is a five year (2009–2014 research programme specifically to address the responses of the earth's atmosphere to both natural and anthropogenic forcings using a host of collocated instruments operational at the National Atmospheric Research Laboratory, Gadanki (13.5° N, 79.2° E, India from a unified viewpoint of studying the vertical coupling between the forcings and responses from surface layer to the ionosphere. As a prelude to the main program a pilot campaign was conducted at Gadanki during May–November 2008 using collocated observations from the MST radar, Rayleigh lidar, GPS balloonsonde, and instruments measuring aerosol, radiation and precipitation, and supporting satellite data. We show the importance of the large radiative heating caused by absorption of solar radiation by soot particles in the lower atmosphere, the observed high vertical winds in the convective updrafts extending up to tropopause, and the difficulty in simulating the same with existing models, the upward traveling waves in the middle atmosphere coupling the lower atmosphere with the upper atmosphere, their manifestation in the mesospheric temperature structure and inversion layers, the mesopause height extending up to 100 km, and the electro-dynamical coupling between mesosphere and the ionosphere which causes irregularities in the ionospheric F-region. The purpose of this communication is not only to share the knowledge that we gained from the SAFAR pilot campaign, but also to inform the international atmospheric science community about the SAFAR program as well as to extend our invitation to join in our journey.

  15. Gait Analysis Study of Runner Using Force Plate

    Directory of Open Access Journals (Sweden)

    Flaviana Catherine

    2017-02-01

    Full Text Available Humans do regular physical activities such as running. Gait is forward  propulsion of the human body using lower extremities as a thrust. Humans gait pattern is characterized by their limbs movement in terms of velocity, ground reaction force, work, kinetic energy and potential energy cycle . Human gait analysis is used to assess, to plan, and to deliver the treatment for individuals based on the conditions that affect their ability to move. Gait analysis is commonly used in running sport to improve the efficiency of athletes in running and to identify problems related to their posture or movement. The aim of this research is to do running gait analysis study of human, using force plate which equipped by track board. The benefit of this study is to provide information, ideas and new perspectives about running and its prevention over an injury. The main method that will be discussed in this study is system design of gait analysis with specific setting, hardware and software, in order to acquire data(s.

  16. An Experimental Study of the Cutting Forces in Metal Turning

    Directory of Open Access Journals (Sweden)

    Zoltan Iosif Korka

    2013-09-01

    Full Text Available Cutting forces are classified among the most important technological parameters in machining process. Cutting forces are the background for the evaluation of the necessary machining power, as well as for dimensioning of the tools. Cutting forces are also having a major influence on the deformation of the work piece machined, its dimensional accuracy, and machining system stability.

  17. Proton NMR Studies of a Large Protein. pH, Substrate Titrations, and NOESY Experiments with Perdeuterated Yeast Phosphoglycerate Kinase Containing [ 1H]Histidine Residues

    Science.gov (United States)

    Pappu, K. M.; Serpersu, E. H.

    Fully deuterated yeast phosphoglycerate kinase ([ 2H]PGK) was prepared biosynthetically with only histidine side chains of normal ( 1H) isotopic composition. The 1H NMR spectrum of this enzyme([ 1H]His[ 2H]PGK) showed that the histidine side chains are clearly visible as sharp signals. Thus detailed structural studies by 1H NMR became feasible with isotope-hybrid phosphoglycerate kinase which is otherwise too large ( Mr ˜ 46,000) for conventional 1H NMR studies. Proton signals of bound substrates were visible in the 1H NMR spectrum even with a substrate-to-enzyme ratio of less than 1/2 (mol/mol). The 2D NOESY spectrum of enzyme-MgdATP-glycerol 3-phosphate complex showed that, although protein concentration was very high (1.5 m M), no intraprotein cross peaks were observed other than those of intraresidue histidine NOE cross peaks. In addition, intrasubstrate NOEs and intermolecular NOEs between histidine and substrate protons were visible at a 1.5/1 substrate/enzyme (mol/mol) ratio. Paramagnetic effects of a substrate analog, Cr(III)ATP, on some of the histidine side chains indicated that the formation of the ternary enzyme-substrate complex causes large conformational changes in the enzyme.

  18. Safety and tolerability of different titration rates of retigabine (ezogabine) in patients with partial-onset seizures.

    Science.gov (United States)

    Biton, Victor; Gil-Nagel, Antonio; Brodie, Martin J; Derossett, Sarah E; Nohria, Virinder

    2013-11-01

    Retigabine (RTG; international nonproprietary name)/ezogabine (EZG; US adopted name) is an antiepileptic drug (AED) that prolongs neuronal voltage-gated potassium-channel KCNQ2-5 (Kv 7.2-7.5) opening. This double-blind study evaluated different RTG/EZG dose-titration rates. Patients (N=73) with partial-onset seizures receiving concomitant AEDs were randomized to one of three titration groups, all of which were initiated at RTG/EZG 300mg/day divided into three equal doses. Fast-, medium-, and slow-titration groups received dose increments of 150mg/day every 2, 4, and 7 days, respectively, achieving the target dose of 1200mg/day after 13, 25, and 43 days, respectively. Safety assessments were performed throughout. Discontinuation rates due to treatment-emergent adverse events (TEAEs) were numerically higher in the fast- (10/23) and medium- (7/22) titration groups than in the slow-titration group (3/23) but statistical significance was achieved only for the high-titration group compared with the low-titration group (p=0.024). Stratified analysis, with concomitant AEDs divided into enzyme inducers (carbamazepine, phenytoin, oxcarbazepine) or noninducers, showed that the risk of discontinuation due primarily to TEAEs was significantly higher in the fast- (p=0.010) but not in the medium-titration group (p=0.078) when compared with the slow-titration group. Overall, the slow-titration rate appeared to be best tolerated and was used in further efficacy and safety studies with RTG/EZG. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Brown algal morphogenesis: Atomic Force Microscopy as a tool to study the role of mechanical forces

    Directory of Open Access Journals (Sweden)

    Benoit eTesson

    2014-09-01

    Full Text Available Over the last few years, a growing interest has been directed toward the use of macroalgae as a source of energy, food and molecules for the cosmetic and pharmaceutical industries. Besides this, macroalgal development remains poorly understood compared to other multicellular organisms. Brown algae (Phaeophyceae form a monophyletic lineage of usually large multicellular algae which evolved independently from land plants. In their environment, they are subjected to strong mechanical forces (current, waves and tide, in response to which they modify rapidly and reversibly their morphology. Because of their specific cellular features (cell wall composition, cytoskeleton organization, deciphering how they cope with these forces might help discover new control mechanisms of cell wall softening and cellulose synthesis. Despite the current scarcity in knowledge on brown algal cell wall dynamics and protein composition, we will illustrate, in the light of methods adapted to Ectocarpus siliculosus, to what extent atomic force microscopy can contribute to advance this field of investigation.

  20. Modelling of acid-base titration curves of mineral assemblages

    Directory of Open Access Journals (Sweden)

    Stamberg Karel

    2016-01-01

    Full Text Available The modelling of acid-base titration curves of mineral assemblages was studied with respect to basic parameters of their surface sites to be obtained. The known modelling approaches, component additivity (CA and generalized composite (GC, and three types of different assemblages (fucoidic sandstones, sedimentary rock-clay and bentonite-magnetite samples were used. In contrary to GC-approach, application of which was without difficulties, the problem of CA-one consisted in the credibility and accessibility of the parameters characterizing the individual mineralogical components.

  1. Government Applications Task Force ground truth study of WAG 4

    International Nuclear Information System (INIS)

    Evers, T.K.; Smyre, J.L.; King, A.L.

    1997-06-01

    This report documents the Government Applications Task Force (GATF) Buried Waste Project. The project was initiated as a field investigation and verification of the 1994 Strategic Environmental Research and Development Program's (SERDP) Buried Waste Identification Project results. The GATF project team included staff from three US Department of Energy (DOE) Laboratories [Oak Ridge National Laboratory (ORNL), Los Alamos National Laboratory (LANL), and the Savannah River Technology Center (SRTC)] and from the National Exploitation Laboratory. Similar studies were conducted at each of the three DOE laboratories to demonstrate the effective use of remote sensing technologies. The three locations were selected to assess differences in buried waste signatures under various environmental conditions (i.e., climate, terrain, precipitation, geology, etc.). After a brief background discussion of the SERDP Project, this report documents the field investigation (ground truth) results from the 1994--1995 GATF Buried Waste Study at ORNL's Waste Area Grouping (WAG) 4. Figures for this report are located in Appendix A

  2. Plutonium titration by controlled potential coulometry; Dosage du plutonium par coulometrie a potentiel impose

    Energy Technology Data Exchange (ETDEWEB)

    Leguay, N.

    2011-07-01

    The LAMMAN (Nuclear Materials Metrology Laboratory) is the support laboratory of the CETAMA (Analytical Method Committee), whose two main activities are developing analytic methods, and making and characterizing reference materials. The LAMMAN chose to develop the controlled potential coulometry because it is a very accurate analytical technique which allows the connection between the quantity of element electrolysed to the quantity of electricity measured thanks to the Faraday's law: it does not require the use of a chemical standard. This method was first used for the plutonium titration and was developed in the Materials Analysis and Metrology Laboratory (LAMM), for upgrading its performances and developing it to the titration of other actinides. The equipment and the material used were developed to allow the work in confined atmosphere (in a glove box), with all the restrictions involved. Plutonium standard solutions are used to qualify the method, and in particular to do titrations with an uncertainty better than 0.1 %. The present study allowed making a bibliographic research about controlled potential coulometry applied to the actinides (plutonium, uranium, neptunium, americium and curium). A full procedure was written to set all the steps of plutonium titration, from the preparation of samples to equipments storage. A method validation was done to check the full procedure, and the experimental conditions: working range, uncertainty, performance... Coulometric titration of the plutonium from pure solution (without interfering elements) was developed to the coulometric titration of the plutonium in presence of uranium, which allows to do accurate analyses for the analyses of some parts of the reprocessing of the spent nuclear fuel. The possibility of developing this method to other actinides than plutonium was highlighted thanks to voltammetric studies, like the coulometric titration of uranium with a working carbon electrode in sulphuric medium. (author)

  3. Implementation of 'Davies and Gray/NBL Method' for potentiometric titration of uranium in the Safeguards Laboratory of CNEN by the use of a DL-67 mettler titrator

    International Nuclear Information System (INIS)

    Araujo, Radier Mario Silveira de; Barros, Pedro Dionisio de

    2005-01-01

    To meet the requirements of the Brazilian State System of Accounting for and Control of Nuclear Materials - SSAC, the Safeguards Laboratory of CNEN - LASAL has been applying the 'Davies and Gray/NBL' method for potentiometric determination of total uranium concentration in uranium samples taken during safeguards inspections at nuclear facilities since 1984, using a Radiometer ETS 822 titrator. In order to improve the analytical capability and the procedures related to the titration methodology, the same method was also implemented by using a METTLER DL - 67 titrator. This equipment is microprocessor - controlled and can be connected to additional devices such as printers, analytical balances, etc. It also provides accurate and reproducible results for end-point titrations, providing analytical performance according to the current international safeguards requirements. The implementation of the method in such equipment included the addition of analytical data as well as the improvement of the equipment parameters for uranium determination. Parameters like predispensing volume; titrant data and end-point value were studied. Some uranium samples (solids and solutions) were used during the initial tests with the titrator. A solution of pure uranyl nitrate was used as reference sample for this paper. From this, aliquots were analyzed in both Radiometer ETS-822 and METTLER DL-67. Results obtained from each equipment were compared with the reference value of the sample. The comparison showed that results from METTLER DL-67 meets the precision and accuracy requirements for this kind of analysis and led to the conclusion that the performance of this titrator is adequate for the determination of total uranium content in samples of nuclear materials for safeguards purposes. (author)

  4. Titratable acidity of beverages influences salivary pH recovery

    Directory of Open Access Journals (Sweden)

    Livia Maria Andaló TENUTA

    2015-01-01

    Full Text Available A low pH and a high titratable acidity of juices and cola-based beverages are relevant factors that contribute to dental erosion, but the relative importance of these properties to maintain salivary pH at demineralizing levels for long periods of time after drinking is unknown. In this crossover study conducted in vivo, orange juice, a cola-based soft drink, and a 10% sucrose solution (negative control were tested. These drinks differ in terms of their pH (3.5 ± 0.04, 2.5 ± 0.05, and 5.9 ± 0.1, respectively and titratable acidity (3.17 ± 0.06, 0.57 ± 0.04 and < 0.005 mmols OH- to reach pH 5.5, respectively. Eight volunteers with a normal salivary flow rate and buffering capacity kept 15 mL of each beverage in their mouth for 10 s, expectorated it, and their saliva was collected after 15, 30, 45, 60, 90, and 120 s. The salivary pH, determined using a mini pH electrode, returned to the baseline value at 30 s after expectoration of the cola-based soft drink, but only at 90 s after expectoration of the orange juice. The salivary pH increased to greater than 5.5 at 15 s after expectoration of the cola drink and at 30 s after expectoration of the orange juice. These findings suggest that the titratable acidity of a beverage influences salivary pH values after drinking acidic beverages more than the beverage pH.

  5. Titratable acidity of beverages influences salivary pH recovery.

    Science.gov (United States)

    Tenuta, Livia Maria Andaló; Fernández, Constanza Estefany; Brandão, Ana Carolina Siqueira; Cury, Jaime Aparecido

    2015-01-01

    A low pH and a high titratable acidity of juices and cola-based beverages are relevant factors that contribute to dental erosion, but the relative importance of these properties to maintain salivary pH at demineralizing levels for long periods of time after drinking is unknown. In this crossover study conducted in vivo, orange juice, a cola-based soft drink, and a 10% sucrose solution (negative control) were tested. These drinks differ in terms of their pH (3.5 ± 0.04, 2.5 ± 0.05, and 5.9 ± 0.1, respectively) and titratable acidity (3.17 ± 0.06, 0.57 ± 0.04 and pH 5.5, respectively). Eight volunteers with a normal salivary flow rate and buffering capacity kept 15 mL of each beverage in their mouth for 10 s, expectorated it, and their saliva was collected after 15, 30, 45, 60, 90, and 120 s. The salivary pH, determined using a mini pH electrode, returned to the baseline value at 30 s after expectoration of the cola-based soft drink, but only at 90 s after expectoration of the orange juice. The salivary pH increased to greater than 5.5 at 15 s after expectoration of the cola drink and at 30 s after expectoration of the orange juice. These findings suggest that the titratable acidity of a beverage influences salivary pH values after drinking acidic beverages more than the beverage pH.

  6. A titration model for evaluating calcium hydroxide removal techniques

    Directory of Open Access Journals (Sweden)

    Mark PHILLIPS

    2015-02-01

    Full Text Available Objective Calcium hydroxide (Ca(OH2 has been used in endodontics as an intracanal medicament due to its antimicrobial effects and its ability to inactivate bacterial endotoxin. The inability to totally remove this intracanal medicament from the root canal system, however, may interfere with the setting of eugenol-based sealers or inhibit bonding of resin to dentin, thus presenting clinical challenges with endodontic treatment. This study used a chemical titration method to measure residual Ca(OH2 left after different endodontic irrigation methods. Material and Methods Eighty-six human canine roots were prepared for obturation. Thirty teeth were filled with known but different amounts of Ca(OH2 for 7 days, which were dissolved out and titrated to quantitate the residual Ca(OH2 recovered from each root to produce a standard curve. Forty-eight of the remaining teeth were filled with equal amounts of Ca(OH2 followed by gross Ca(OH2 removal using hand files and randomized treatment of either: 1 Syringe irrigation; 2 Syringe irrigation with use of an apical file; 3 Syringe irrigation with added 30 s of passive ultrasonic irrigation (PUI, or 4 Syringe irrigation with apical file and PUI (n=12/group. Residual Ca(OH2 was dissolved with glycerin and titrated to measure residual Ca(OH2 left in the root. Results No method completely removed all residual Ca(OH2. The addition of 30 s PUI with or without apical file use removed Ca(OH2 significantly better than irrigation alone. Conclusions This technique allowed quantification of residual Ca(OH2. The use of PUI (with or without apical file resulted in significantly lower Ca(OH2 residue compared to irrigation alone.

  7. Experimental study on inter-particle acoustic forces.

    Science.gov (United States)

    Garcia-Sabaté, Anna; Castro, Angélica; Hoyos, Mauricio; González-Cinca, Ricard

    2014-03-01

    A method for the experimental measurement of inter-particle forces (secondary Bjerknes force) generated by the action of an acoustic field in a resonator micro-channel is presented. The acoustic radiation force created by an ultrasonic standing wave moves suspended particles towards the pressure nodes and the acoustic pressure induces particle volume oscillations. Once particles are in the levitation plane, transverse and secondary Bjerknes forces become important. Experiments were carried out in a resonator filled with a suspension composed of water and latex particles of different size (5-15 μm) at different concentrations. Ultrasound was generated by means of a 2.5 MHz nominal frequency transducer. For the first time the acoustic force generated by oscillating particles acting on other particles has been measured, and the critical interaction distance in various cases has been determined. Inter-particle forces on the order of 10(-14) N have been measured by using this method.

  8. Titration ELISA as a Method to Determine the Dissociation Constant of Receptor Ligand Interaction.

    Science.gov (United States)

    Eble, Johannes A

    2018-02-15

    The dissociation constant describes the interaction between two partners in the binding equilibrium and is a measure of their affinity. It is a crucial parameter to compare different ligands, e.g., competitive inhibitors, protein isoforms and mutants, for their binding strength to a binding partner. Dissociation constants are determined by plotting concentrations of bound versus free ligand as binding curves. In contrast, titration curves, in which a signal that is proportional to the concentration of bound ligand is plotted against the total concentration of added ligand, are much easier to record. The signal can be detected spectroscopically and by enzyme-linked immunosorbent assay (ELISA). This is exemplified in a protocol for a titration ELISA that measures the binding of the snake venom-derived rhodocetin to its immobilized target domain of α2β1 integrin. Titration ELISAs are versatile and widely used. Any pair of interacting proteins can be used as immobilized receptor and soluble ligand, provided that both proteins are pure, and their concentrations are known. The difficulty so far has been to determine the dissociation constant from a titration curve. In this study, a mathematical function underlying titration curves is introduced. Without any error-prone graphical estimation of a saturation yield, this algorithm allows processing of the raw data (signal intensities at different concentrations of added ligand) directly by mathematical evaluation via non-linear regression. Thus, several titration curves can be recorded simultaneously and transformed into a set of characteristic parameters, among them the dissociation constant and the concentration of binding-active receptor, and they can be evaluated statistically. When combined with this algorithm, titration ELISAs gain the advantage of directly presenting the dissociation constant. Therefore, they may be used more efficiently in the future.

  9. Titrated flow versus fixed flow Bubble Nasal CPAP for respiratory distress in preterm neonates.

    Directory of Open Access Journals (Sweden)

    Srinivas eMurki

    2015-10-01

    Full Text Available Background: The clinical effects of a pre-fixed flow of air-oxygen versus a flow titrated according to visible bubbling are not well understood.Objective: To compare the effects of a fixed flow (5 L/min and titrated flow ( flow just enough to ensure bubbling at different set pressures on delivered intra-prong pressure, gas exchange and clinical parameters in preterm infants on bubble CPAP for respiratory distress.Methods: Preterm infants less than 35 weeks gestation on bubble CPAP and less than 96 h of age, were enrolled in this cross over study. They were subjected to 30 minute periods of titrated flow and fixed flow. At the end of both epochs, gas flow rate, set pressure, FiO2, SpO2, Silverman retraction score, respiratory rate , abdominal girth, and blood gases were recorded. The delivered intra-prong pressure was measured by an electronic manometer. Results: Sixty nine recordings were made in 54 infants. For each of the set CPAP pressures (4, 5 and 6 cm H2O, the mean delivered pressure with a fixed flow of 5 L/min was higher than that delivered by the titrated flow. During the fixed flow epoch, the delivered pressure was closer to and higher than the set pressure resulting in higher PaO2 and lower PaCO2 as compared to titrated flow epoch. In the titrated flow period, the delivered pressure was consistently lower than the set pressure. Conclusion: In preterm infants on bubble CPAP with set pressures of 4 to 6 cm H2O, a fixed flow of 5 L/min is more effective than a flow titrated to ensure adequate visible bubbling. It achieves higher delivered pressures, better oxygenation and ventilation.

  10. Thermal desorption study of physical forces at the PTFE surface

    Science.gov (United States)

    Wheeler, D. R.; Pepper, S. V.

    1987-01-01

    Thermal desorption spectroscopy (TDS) of the polytetrafluoroethylene (PTFE) surface was successfully employed to study the possible role of physical forces in the enhancement of metal-PTFE adhesion by radiation. The thermal desorption spectra were analyzed without assumptions to yield the activation energy for desorption over a range of xenon coverage from less than 0.1 monolayer to more than 100 monolayers. For multilayer coverage, the desorption is zero-order with an activation energy equal to the sublimation energy of xenon. For submonolayer coverages, the order for desorption from the unirradiated PTFE surface is 0.73 and the activation energy for desorption is between 3.32 and 3.36 kcal/mol; less than the xenon sublimation energy. The effect of irradiation is to increase the activation energy for desorption to as high as 4 kcal/mol at low coverage.

  11. Determination of neptunium by redox titration

    International Nuclear Information System (INIS)

    Godbole, A.G.; Patil, S.K.

    1979-01-01

    A simple and quick method for the potentiometric determination of neptunium on the 2 to 5 mg scale has been developed. It consists of oxidation to Np(VI) by AgO or fuming with HClO 4 , destruction of excess of AgO by sulphamic acid, reduction of Np(VI) to Np(IV) with a slight excess of standard Fe(II) in 2M H 2 SO 4 and potentiometric titration of the excess of Fe(II) with standard Ce(IV). The precision is +- 0.5%. (author)

  12. Titration of uranium trace amounts in waters environment

    International Nuclear Information System (INIS)

    Larabi-Gruet, N.; Ithurbide, A.; Poulesquen, A.; Beaucaire, C.; Peulon, S.; Chausse, A.

    2007-01-01

    In the framework of studies concerning the uranium migration in soils and rocks, it seems necessary to quantify the uranium(VI) dissolved in solution. In the environmental conditions, the uranium(VI) is present at trace amounts. The most adapted method to this study and easy to carry out is the Adsorptive Stripping Voltammetry. By addition of a compound (ligand) with a reducing and strong complexing power, the uranium(VI) present in solution is reduced into a U(VI)-ligand complex. This specie is then oxidized and adsorbed on the mercury droplet where an electrolytic pre-concentration of the element to determine the quantity of is carried out. At last, a cathodic re-dissolution of the specie adsorbed in the U(IV)-ligand complex is carried out. The chosen analytical method is the differential impulsional voltammetry. With this method, it is possible to quantify low electro-active species quantities (sensitivity ∼25 ppt (10 -10 mol.L -1 ) for the uranium). This titration method in solution has been optimized, at first, in a non complexing medium. Then, the uranium in solution has been titrated in media whose composition has been progressively complexed (additions of CO 3 2- , SO 4 2- , Cl - ..) for being at last representative of the environmental interstitial waters. At last, this study has been carried out too by ICP-MS (Inductively Coupled Plasma-Mass Spectrometry) in order to compare the analysis sensitivity of these two detection methods. (O.M.)

  13. A Climatological Study of Hurricane Force Extratropical Cyclones

    Science.gov (United States)

    2012-03-01

    extratropical cyclone by months in the Pacific basin. Most of the storms occur from October through March...hurricane force extratropical cyclone. Starting from left to right; the first column is the storm name, second column is the year, month, day, hour (UTC...2000 through 2007 illustrates that the number of hurricane-force extratropical cyclones is quite significant: approximately 500 storms , nearly evenly

  14. Direct measurements of intermolecular forces by chemical force microscopy

    Science.gov (United States)

    Vezenov, Dmitri Vitalievich

    1999-12-01

    Detailed description of intermolecular forces is key to understanding a wide range of phenomena from molecular recognition to materials failure. The unique features of atomic force microscopy (AFM) to make point contact force measurements with ultra high sensitivity and to generate spatial maps of surface topography and forces have been extended to include measurements between well-defined organic molecular groups. Chemical modification of AFM probes with self-assembled monolayers (SAMs) was used to make them sensitive to specific molecular interactions. This novel chemical force microscopy (CFM) technique was used to probe forces between different molecular groups in a range of environments (vacuum, organic liquids and aqueous solutions); measure surface energetics on a nanometer scale; determine pK values of the surface acid and base groups; measure forces to stretch and unbind a short synthetic DNA duplex and map the spatial distribution of specific functional groups and their ionization state. Studies of adhesion forces demonstrated the important contribution of hydrogen bonding to interactions between simple organic functionalities. The chemical identity of the tip and substrate surfaces as well as the medium had a dramatic effect on adhesion between model monolayers. A direct correlation between surface free energy and adhesion forces was established. The adhesion between epoxy polymer and model mixed SAMs varied with the amount of hydrogen bonding component in the monolayers. A consistent interpretation of CFM measurements in polar solvents was provided by contact mechanics models and intermolecular force components theory. Forces between tips and surfaces functionalized with SAMs terminating in acid or base groups depended on their ionization state. A novel method of force titration was introduced for highly local characterization of the pK's of surface functional groups. The pH-dependent changes in friction forces were exploited to map spatially the

  15. Vegetation studies on Vandenberg Air Force Base, California

    Science.gov (United States)

    Schmalzer, Paul A.; Hickson, Diana E.; Hinkle, C. Ross

    1988-01-01

    Vandenburg Air Force Base, located in coastal central California with an area of 98,400 ac, contains resources of considerable biological significance. Available information on the vegetation and flora of Vandenburg is summarized and new data collected in this project are presented. A bibliography of 621 references dealing with vegetation and related topics related to Vanderburg was compiled from computer and manual literature searches and a review of past studies of the base. A preliminary floristic list of 642 taxa representing 311 genera and 80 families was compiled from past studies and plants identified in the vegetation sampling conducted in this project. Fifty-two special interest plant species are known to occur or were suggested to occur. Vegetation was sampled using permanent plots and transects in all major plant communities including chaparral, Bishop pine forest, tanbark oak forest, annual grassland, oak woodland, coastal sage scrub, purple sage scrub, coastal dune scrub, coastal dunes, box elder riparian woodland, will riparian woodland, freshwater marsh, salt marsh, and seasonal wetlands. Comparison of the new vegetation data to the compostie San Diego State University data does not indicate major changes in most communities since the original study. Recommendations are made for additional studies needed to maintain and extend the environmental data base and for management actions to improve resource protection.

  16. Effectiveness on mild stress and mixed urinary incontinence and impact on Quality of Life of a phytotherapic product containing astragalus, thyme, lavender, hop, equisetum, red clover, cypress and agrimonia at titrated concentrations. Results from a monocentric study

    Directory of Open Access Journals (Sweden)

    Oreste Risi

    2017-12-01

    Full Text Available Objectives: To assess any beneficial effect on quality of life of a daily treatment with a phytotherapic product containing astragalus, thyme, lavender, hop, equisetum, red clover, cypress and agrimonia at titrated concentrations in a cohort of female patients complaining mild stress urinary incontinence (SUI or mixed urinary incontinence (MUI. Materials and methods: 42 non-consecutive female out-patients with mild SUI or mild MUI were assessed with a clinical evaluation, International Consultation on Incontinence Questionnaire Short Form (ICIQ-SF and Patients’ Perception of Intensity of Urgency Scale (PPIUS at baseline the start of the study and after two months of therapy with the phytotherapic product. At the end of the therapy the patients also compiled Patient Global Impression of Improvement (PGI-I. Results: After the completion of the study there was a trend towards better results in each item of ICIQ-SF, but without any statistical significance with an average score in ICIQ-SF-1 of 3.12 ± 0.981 versus 3.21 ± 0.914 (p = 0.556, in ICIQ-SF-2 of 3.69 ± 1.422 versus 3.79 ± 1.372 (p = 0.68 and in ICIQ-SF-3 of 5.95 ± 1.618 versus 6.14 ± 1.670 (p = 0.462. The average reduction of PPIUS was of 0.09 (1.26 ± 1.481 versus 1.357 ± 1.509, p = 0.705. There was a reduction of average consumption of pads/die from 1.69 ± 0.636 to 1.54 ± 0.543 (p = 0.101. In relation to the PGI score, 23/42 patients (54.7% reported no changes after the completion of the therapy, 13/42 (30.9% reported a slight improvement, 5/42 (11.9% were much improved and 1/42 (2.3% was slightly worsened. Only 2/42 (4.7% patients discontinued the treatment before of the completion of the study. We did not observe any adverse effects during the period of the study. Conclusions: The phytotherapic product seems to cause a slight improvement of the symptoms in a good rate of patients. Moreover it has a low rate of withdrawal, due to the lack of adverse events.

  17. Effectiveness on mild stress and mixed urinary incontinence and impact on Quality of Life of a phytotherapic product containing astragalus, thyme, lavender, hop, equisetum, red clover, cypress and agrimonia at titrated concentrations. Results from a monocentric study.

    Science.gov (United States)

    Risi, Oreste; Manica, Michele; Lisanti, Rocca Carmela; Manfredi, Antonio; Tecci, Giuseppe Romeo

    2017-12-31

    To assess any beneficial effect on quality of life of a daily treatment with a phytotherapic product containing astragalus, thyme, lavender, hop, equisetum, red clover, cypress and agrimonia at titrated concentrations in a cohort of female patients complaining mild stress urinary incontinence (SUI) or mixed urinary incontinence (MUI). 42 non-consecutive female out-patients with mild SUI or mild MUI were assessed with a clinical evaluation, International Consultation on Incontinence Questionnaire Short Form (ICIQ-SF) and Patients' Perception of Intensity of Urgency Scale (PPIUS) at baseline the start of the study and after two months of therapy with the phytotherapic product. At the end of the therapy the patients also compiled Patient Global Impression of Improvement (PGI-I). After the completion of the study there was a trend towards better results in each item of ICIQ-SF, but without any statistical significance with an average score in ICIQ-SF-1 of 3.12 ± 0.981 versus 3.21 ± 0.914 (p = 0.556), in ICIQ-SF-2 of 3.69 ± 1.422 versus 3.79 ± 1.372 (p = 0.68) and in ICIQ-SF-3 of 5.95 ± 1.618 versus 6.14 ± 1.670 (p = 0.462). The average reduction of PPIUS was of 0.09 (1.26 ± 1.481 versus 1.357 ± 1.509, p = 0.705). There was a reduction of average consumption of pads/die from 1.69 ± 0.636 to 1.54 ± 0.543 (p = 0.101). In relation to the PGI score, 23/42 patients (54.7%) reported no changes after the completion of the therapy, 13/42 (30.9%) reported a slight improvement, 5/42 (11.9%) were much improved and 1/42 (2.3%) was slightly worsened. Only 2/42 (4.7%) patients discontinued the treatment before of the completion of the study. We did not observe any adverse effects during the period of the study. The phytotherapic product seems to cause a slight improvement of the symptoms in a good rate of patients. Moreover it has a low rate of withdrawal, due to the lack of adverse events.

  18. Improving medication titration in heart failure by embedding a structured medication titration plan.

    Science.gov (United States)

    Hickey, Annabel; Suna, Jessica; Marquart, Louise; Denaro, Charles; Javorsky, George; Munns, Andrew; Mudge, Alison; Atherton, John J

    2016-12-01

    To improve up-titration of medications to target dose in heart failure patients by improving communication from hospital to primary care. This quality improvement project was undertaken within three heart failure disease management (HFDM) services in Queensland, Australia. A structured medication plan was collaboratively designed and implemented in an iterative manner, using methods including awareness raising and education, audit and feedback, integration into existing work practice, and incentive payments. Evaluation was undertaken using sequential audits, and included process measures (use of the titration plan, assignment of responsibility) and outcome measures (proportion of patients achieving target dose) in HFDM service patients with reduced left ventricular ejection fraction. Comparison of the three patient cohorts (pre-intervention cohort A n=96, intervention cohort B n=95, intervention cohort C n=89) showed increase use of the titration plan, a shift to greater primary care responsibility for titration, and an increase in the proportion of patients achieving target doses of angiotensin converting enzyme inhibitors/angiotensin receptor blockers (ACEI/ARB) (A 37% vs B 48% vs C 55%, p=0.051) and beta-blockers (A 38% vs B 33% vs C 51%, p=0.045). Combining all three cohorts, patients not on target doses when discharged from hospital were more likely to achieve target doses of ACEI/ARB (pplan. A medication titration plan was successfully implemented in three HFDM services and improved transitional communication and achievement of target doses of evidence-based therapies within six months of hospital discharge. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Comparison of the clinical outcomes between unattended home APAP and polysomnography manual titration in obstructive sleep apnea patients.

    Science.gov (United States)

    Wongsritrang, Krongthong; Fueangkamloon, Sumet

    2013-09-01

    To compare the clinical outcomes and determine the difference in therapeutic pressure between Automatic positive airway pressure (APAP) and polysomnography manual titration. Fifty patients of obstructive sleep apnea (OSA), moderate to severe cases, were randomized into two groups of intervention: 95-percentile pressure derived from APAP titration and an optimal pressure derived from manual titration. Clinical outcomes were assessed before and after four weeks. The average 95-percentile pressure derived from APAP titration was 11.7 +/- 0.3 cmH2O with median mask leak 1.3 L/min. The average optimal pressure derived from manual titration was 8.2 +/- 0.3 cmH2O. Pearson correlation analysis showed weak positive correlation (r = 0.336, p = 0.017). The Epworth Sleepiness Score (ESS), Quality of life tests: PSQI (Pittsburg Sleep Quality Index), and SF-36 (Medical Outcomes Study 36-Item Short-Form Health Survey) were improved significantly in both groups, but there were no statistical significant differences between groups. An APAP titration is an effective method of pressure determination for conventional CPAP therapy and shows no difference in clinical outcomes comparing the standard titration.

  20. Down-titration of biologics for the treatment of rheumatoid arthritis: a systematic literature review.

    Science.gov (United States)

    Lau, Chak Sing; Gibofsky, Allan; Damjanov, Nemanja; Lula, Sadiq; Marshall, Lisa; Jones, Heather; Emery, Paul

    2017-11-01

    Biologic therapies have improved the management of rheumatoid arthritis (RA) and the treat-to-target approach has resulted in many patients achieving remission. In the current treatment landscape, clinicians have begun considering dose reduction/tapering for their patients. Rheumatology guidelines in Asia, Europe, and the United States include down-titration of biologics but admit that the level of evidence is moderate. We conducted a systematic literature review to assess the published studies that evaluate down-titration of biologics in RA. The published literature was searched for studies that down-titrated the following biologics: abatacept, adalimumab, certolizumab, etanercept, golimumab, infliximab, rituximab, and tocilizumab. Eligible studies included randomized controlled trials (RCTs), non-RCTs, observational, and pharmacoeconomic studies. The outcomes of interest were (1) efficacy and health-related quality of life, (2) disease flares, and (3) impact on cost. Eleven full-text publications were identified; only three were RCTs. Study results suggest that dosing down may be an option in many patients who have achieved remission or low disease activity. However, some patients are likely to experience a disease flare. Across the studies, the definition of disease flare and the down-titration criteria were inconsistent, making it difficult to conclude which patients may be appropriate and when to attempt down-titration. Studies have evaluated the practice of dosing down biologic therapy in patients with RA; however, a relatively small number of RCTs have been published. Although down-titration may be an option for some patients in LDA or remission, additional RCTs are needed to provide guidance on this practice.

  1. Automated titration method for use on blended asphalts

    Science.gov (United States)

    Pauli, Adam T [Cheyenne, WY; Robertson, Raymond E [Laramie, WY; Branthaver, Jan F [Chatham, IL; Schabron, John F [Laramie, WY

    2012-08-07

    A system for determining parameters and compatibility of a substance such as an asphalt or other petroleum substance uses titration to highly accurately determine one or more flocculation occurrences and is especially applicable to the determination or use of Heithaus parameters and optimal mixing of various asphalt stocks. In a preferred embodiment, automated titration in an oxygen gas exclusive system and further using spectrophotometric analysis (2-8) of solution turbidity is presented. A reversible titration technique enabling in-situ titration measurement of various solution concentrations is also presented.

  2. Laboratory Automatic Titration of Chromium Plating and Electropolishing Solutions

    National Research Council Canada - National Science Library

    Sopok, Samuel

    2001-01-01

    .... The analytical chemistry literature lacks an adequate automatic titration method for the monitoring of chromic acid in chromium plating solutions and the monitoring of phosphoric and sulfuric acids...

  3. Titration in the treatment of the more troubled patient.

    Science.gov (United States)

    Winer, J A; Ornstein, E D

    2001-01-01

    This article defines and discusses a modification of technique recommended by the authors in the psychoanalytic treatment of more troubled patients--a modification they call titration. Titration is defined as a conscious decision by the analyst to increase or decrease assistance (or gratification) gradually, in order to facilitate the analytic process. The authors emphasize the complexity of decisions in treatment by focusing on the decision-making processes that titration requires. Guidelines and a case vignette are presented. The authors conclude by considering some of the politics involved in the introduction of technique modifications, the salience of the titration concept, and directions for further exploration.

  4. A computer controlled potentiometric titrator for quantitative determination of uranium

    International Nuclear Information System (INIS)

    Verdingh, V.; Michiels, A.

    1988-01-01

    The modified Davies and Gray methods is frequently used for the potentiometric titration of uranium. It is based upon the reduction of U(VI) to U(IV) with a reductant (e.g. Fe ++ ) followed by a selective oxidation of the excess of reductant and subsequent titration of U(IV) with potassium dichromate (K 2 Cr 2 O 7 ). Interference from other elements is low, but the method is rather cumbersome due to the number of reactants to be added before the titration is started. The timing of these additions also plays a role. In order to render the titration less dependent on human factors and with the aim of reaching high reproducibility, a computer controlled system has been designed and set-up. Reagents are added by five computer controlled burettes. A program allows the choice of volumes and waiting times, and commands the start of the final titration which is followed by the microprocessor of the automatic potentiometric titrator. In this way a routine uranium titration can be completed in about twelve minutes. Reproducibilities of the order of ±15% are achievable in routine operation. For high precision work, the titrator is used as an end-point detector. Titrant is added manually by mass, so as to react with > 99% of the uranium. The residual uranium is then titrated automatically by colume with diluted titrant. The precision can be improved by a factor of approximately ten. (orig.)

  5. Influence of kinetics on the determination of the surface reactivity of oxide suspensions by acid-base titration.

    Science.gov (United States)

    Duc, M; Adekola, F; Lefèvre, G; Fédoroff, M

    2006-11-01

    The effect of acid-base titration protocol and speed on pH measurement and surface charge calculation was studied on suspensions of gamma-alumina, hematite, goethite, and silica, whose size and porosity have been well characterized. The titration protocol has an important effect on surface charge calculation as well as on acid-base constants obtained by fitting of the titration curves. Variations of pH versus time after addition of acid or base to the suspension were interpreted as diffusion processes. Resulting apparent diffusion coefficients depend on the nature of the oxide and on its porosity.

  6. Molecular modeling studies of structural properties of polyvinyl alcohol: a comparative study using INTERFACE force field.

    Science.gov (United States)

    Radosinski, Lukasz; Labus, Karolina

    2017-10-05

    Polyvinyl alcohol (PVA) is a material with a variety of applications in separation, biotechnology, and biomedicine. Using combined Monte Carlo and molecular dynamics techniques, we present an extensive comparative study of second- and third-generation force fields Universal, COMPASS, COMPASS II, PCFF, and the newly developed INTERFACE, as applied to this system. In particular, we show that an INTERFACE force field provides a possibility of composing a reliable atomistic model to reproduce density change of PVA matrix in a narrow temperature range (298-348 K) and calculate a thermal expansion coefficient with reasonable accuracy. Thus, the INTERFACE force field may be used to predict mechanical properties of the PVA system, being a scaffold for hydrogels, with much greater accuracy than latter approaches. Graphical abstract Molecular Dynamics and Monte Carlo studies indicate that it is possible to predict properties of the PVA in narrow temperature range by using the INTERFACE force field.

  7. Determination of trace amounts of thorium and lanthanides by successive titrations using semi-xylenol orange with spectrophotometric end-point indication

    International Nuclear Information System (INIS)

    Hafez, M.A.E.; Abdallah, A.M.A.; El-Gany, N.E.A.

    1990-01-01

    The precision and accuracy attainable in successive titrations of Th 4+ and either La 3+ , Nd 3+ or Gd 3+ with a 0.001 M solution of disodium ethylenediaminetetraacetate using Semi-xylenol Orange (SXO) as a metallochromic indicator were studied. Thorium (IV) was titrated at pH 2, the pH was adjusted to 5.5-5.9 by adding hexamethylenetetramine buffer and La 3+ (or Nd 3+ or Gd 3+ ) was then titrated. A comparison of the indicators SXO and Xylenol Orange for successive titrations of Th 4+ and either La 3+ , Nd 3+ or Gd 3+ was carried out. (author)

  8. Constant-pH molecular dynamics using stochastic titration

    Science.gov (United States)

    Baptista, António M.; Teixeira, Vitor H.; Soares, Cláudio M.

    2002-09-01

    A new method is proposed for performing constant-pH molecular dynamics (MD) simulations, that is, MD simulations where pH is one of the external thermodynamic parameters, like the temperature or the pressure. The protonation state of each titrable site in the solute is allowed to change during a molecular mechanics (MM) MD simulation, the new states being obtained from a combination of continuum electrostatics (CE) calculations and Monte Carlo (MC) simulation of protonation equilibrium. The coupling between the MM/MD and CE/MC algorithms is done in a way that ensures a proper Markov chain, sampling from the intended semigrand canonical distribution. This stochastic titration method is applied to succinic acid, aimed at illustrating the method and examining the choice of its adjustable parameters. The complete titration of succinic acid, using constant-pH MD simulations at different pH values, gives a clear picture of the coupling between the trans/gauche isomerization and the protonation process, making it possible to reconcile some apparently contradictory results of previous studies. The present constant-pH MD method is shown to require a moderate increase of computational cost when compared to the usual MD method.

  9. Common Standards of Basal Insulin Titration in T2DM

    Science.gov (United States)

    Arnolds, Sabine; Heise, Tim; Flacke, Frank; Sieber, Jochen

    2013-01-01

    Type 2 diabetes mellitus has become a worldwide major health problem, and the number of people affected is steadily increasing. Thus, not all patients suffering from the disease can be treated by specialized diabetes centers or outpatient clinics, but by primary care physicians. The latter, however, might have time constraints and have to deal with many kinds of diseases or with multimorbid patients, so their focus is not so much on lowering high blood glucose values. Thus, the physicians, as well as the patients themselves, are often reluctant to initiate and adjust insulin therapy, although basal insulin therapy is considered the appropriate strategy after oral antidiabetic drug failure, according to the latest international guidelines. A substantial number of clinical studies have shown that insulin initiation and optimization can be managed successfully by using titration algorithms—even in cases where patients themselves are the drivers of insulin titration. Nevertheless, tools and strategies are needed to facilitate this process in the daily life of both primary health care professionals and patients with diabetes. PMID:23759411

  10. Fast Proton Titration Scheme for Multiscale Modeling of Protein Solutions.

    Science.gov (United States)

    Teixeira, Andre Azevedo Reis; Lund, Mikael; da Silva, Fernando Luís Barroso

    2010-10-12

    Proton exchange between titratable amino acid residues and the surrounding solution gives rise to exciting electric processes in proteins. We present a proton titration scheme for studying acid-base equilibria in Metropolis Monte Carlo simulations where salt is treated at the Debye-Hückel level. The method, rooted in the Kirkwood model of impenetrable spheres, is applied on the three milk proteins α-lactalbumin, β-lactoglobulin, and lactoferrin, for which we investigate the net-charge, molecular dipole moment, and charge capacitance. Over a wide range of pH and salt conditions, excellent agreement is found with more elaborate simulations where salt is explicitly included. The implicit salt scheme is orders of magnitude faster than the explicit analog and allows for transparent interpretation of physical mechanisms. It is shown how the method can be expanded to multiscale modeling of aqueous salt solutions of many biomolecules with nonstatic charge distributions. Important examples are protein-protein aggregation, protein-polyelectrolyte complexation, and protein-membrane association.

  11. High frequency titration in non-aqueous solvents. Application to HF and UF6

    International Nuclear Information System (INIS)

    Neveu, Claude

    1965-01-01

    In this research thesis, the author first presents the main theoretical notions regarding high frequency titration, notably by studying characteristic curves, i.e. the titration meter indication with respect to conductibility. He reports the use of this method for the study of various reactions in non-aqueous medium: reaction of AlCl 3 with pyridine in acetonitrile, of AlCl 3 with HCl in tetrachloroethane and in nitromethane. He also reports the attempt of application of this method to the titration of HF in presence of UF 6 in CCl 4 as solvent, or by using F acceptors like BF 3 , PF 5 or ClF 3 as reactants [fr

  12. Polyelectrolyte brushes in mixed ionic medium studied via intermolecular forces

    Science.gov (United States)

    Farina, Robert; Laugel, Nicolas; Pincus, Philip; Tirrell, Matthew

    2011-03-01

    The vast uses and applications of polyelectrolyte brushes make them an attractive field of research especially with the growing interest in responsive materials. Polymers which respond via changes in temperature, pH, and ionic strength are increasingly being used for applications in drug delivery, chemical gating, etc. When polyelectrolyte brushes are found in either nature (e.g., surfaces of cartilage and mammalian lung interiors) or commercially (e.g., skin care products, shampoo, and surfaces of medical devices) they are always surrounded by mixed ionic medium. This makes the study of these brushes in varying ionic environments extremely relevant for both current and future potential applications. The polyelectrolyte brushes in this work are diblock co-polymers of poly-styrene sulfonate (N=420) and poly-t-butyl styrene (N=20) which tethers to a hydrophobic surface allowing for a purely thermodynamic study of the polyelectrolyte chains. Intermolecular forces between two brushes are measured using the SFA. As multi-valent concentrations are increased, the brushes collapse internally and form strong adhesion between one another after contact (properties not seen in a purely mono-valent environment).

  13. Remission in children and adolescents diagnosed with attention-deficit/hyperactivity disorder via an effective and tolerable titration scheme for osmotic release oral system methylphenidate.

    Science.gov (United States)

    Chou, Wen-Jiun; Chen, Shin-Jaw; Chen, Ying-Sheue; Liang, Hsin-Yi; Lin, Chih-Chien; Tang, Ching-Shu; Huang, Yu-Shu; Yeh, Chin-Bin; Chou, Miao-Chun; Lin, Dai-Yueh; Hou, Po-Hsun; Wu, Yu-Yu; Liu, Hung-Jen; Huang, Ya-Fen; Hwang, Kai-Ling; Chan, Chin-Hong; Pan, Chia-Ho; Chang, Hsueh-Ling; Huang, Chi-Fen; Hsu, Ju-Wei

    2012-06-01

    The purpose of this study was to identify the optimal dose of osmotic release oral system methylphenidate (OROS-MPH) using a dosage forced-titration scheme to achieve symptomatic remission in children with attention- deficit/hyperactivity disorder (ADHD). We also evaluated the efficacy and safety of, and patient and parent satisfaction with, the change in therapy from immediate-release methylphenidate (IR-MPH) to OROS-MPH over 10 weeks. We recruited 521 children and adolescents aged 6-18 years with an American Psychiatric Association, Diagnostic and Statistical Manual of Mental Disorders, 4th ed. (DSM-IV) diagnosis of ADHD, who had received IR-MPH treatments (titration phase of OROS-MPH to achieve symptomatic remission (defined as a score of 0 or 1 for each of the first 18 ADHD items in the Chinese version of the Swanson, Nolan, and Pelham, Version IV [SNAP-IV]), followed by a 4-week maintenance phase. The global ADHD severity and drug side effects of the participants were evaluated. Parents completed the ratings scales for the ADHD-related symptoms. Patient and parent satisfaction for the OROS-MPH treatment was also assessed. Among the 439 participants with ADHD who completed the trial, 290 participants (66.1%) achieved symptomatic remission. The mean dose of OROS-MPH among participants in remission was 36.7 mg (1.08 mg/kg) per day. Increased efficacy, superior satisfaction, and safety equivalent to that of IR-MPH were demonstrated in intra-individual comparisons from the baseline to the end of study. Determinants for remission included less severe ADHD symptoms (SNAP-IV score history of ADHD, and an appropriate dosage of medication according to the patient's weight. The findings suggest remission as a treatment goal for ADHD therapy by providing an optimal dosage of medication for children and adolescents with ADHD through using an effective and tolerable forced-titration scheme.

  14. Canadian Forces Experience with Turbofan HCF - Case Study

    National Research Council Canada - National Science Library

    Kinart, Corey; Theriault, Pierre

    2005-01-01

    High Cycle Fatigue (HCF) cracking of a Canadian Forces (CF) turbofan engine fuel tube resulted in a six year, multinational effort to identify the root cause and to ultimately develop and implement a solution...

  15. Motor unit firing rate patterns during voluntary muscle force generation: a simulation study

    Science.gov (United States)

    Hu, Xiaogang; Rymer, William Z.; Suresh, Nina L.

    2014-04-01

    Objective. Muscle force is generated by a combination of motor unit (MU) recruitment and changes in the discharge rate of active MUs. There have been two basic MU recruitment and firing rate paradigms reported in the literature, which describe the control of the MUs during force generation. The first (termed the reverse ‘onion skin’ profile), exhibits lower firing rates for lower threshold units, with higher firing rates occurring in higher threshold units. The second (termed the ‘onion skin’ profile), exhibits an inverse arrangement, with lower threshold units reaching higher firing rates. Approach. Using a simulation of the MU activity in a hand muscle, this study examined the force generation capacity and the variability of the muscle force magnitude at different excitation levels of the MU pool under these two different MU control paradigms. We sought to determine which rate/recruitment scheme was more efficient for force generation, and which scheme gave rise to the lowest force variability. Main results. We found that the force output of both firing patterns leads to graded force output at low excitation levels, and that the force generation capacity of the two different paradigms diverged around 50% excitation. In the reverse ‘onion skin’ pattern, at 100% excitation, the force output reached up to 88% of maximum force, whereas for the ‘onion skin’ pattern, the force output only reached up to 54% of maximum force at 100% excitation. The force variability was lower at the low to moderate force levels under the ‘onion skin’ paradigm than with the reverse ‘onion skin’ firing patterns, but this effect was reversed at high force levels. Significance. This study captures the influence of MU recruitment and firing rate organization on muscle force properties, and our results suggest that the different firing organizations can be beneficial at different levels of voluntary muscle force generation and perhaps for different tasks.

  16. US/UK Sensor-To-Shooter Multinational C4 Interoperability Study Force-On-Force Effectiveness Methodology

    Science.gov (United States)

    2000-10-01

    performance. A team of military and Multiple gamers and analysts Augmented by Study SMEs •Threats •Service reps •Scenario •Data Typical VIC Team...OPLAN) for the Combined Forces Command (CFC) in Korea . CFC has since requested TRAC to conduct similar analyses on the new OPLANs during 1999-2000

  17. The acid-base titration of montmorillonite

    Science.gov (United States)

    Bourg, I. C.; Sposito, G.; Bourg, A. C.

    2003-12-01

    Proton binding to clay minerals plays an important role in the chemical reactivity of soils (e.g., acidification, retention of nutrients or pollutants). If should also affect the performance of clay barriers for waste disposal. The surface acidity of clay minerals is commonly modelled empirically by assuming generic amphoteric surface sites (>SOH) on a flat surface, with fitted site densities and acidity constant. Current advances in experimental methods (notably spectroscopy) are rapidly improving our understanding of the structure and reactivity of the surface of clay minerals (arrangement of the particles, nature of the reactive surface sites, adsorption mechanisms). These developments are motivated by the difficulty of modelling the surface chemistry of mineral surfaces at the macro-scale (e.g., adsorption or titration) without a detailed (molecular-scale) picture of the mechanisms, and should be progressively incorporated into surface complexation models. In this view, we have combined recent estimates of montmorillonite surface properties (surface site density and structure, edge surface area, surface electrostatic potential) with surface site acidities obtained from the titration of alpha-Al2O3 and SiO2, and a novel method of accounting for the unknown initial net proton surface charge of the solid. The model predictions were compared to experimental titrations of SWy-1 montmorillonite and purified MX-80 bentonite in 0.1-0.5 mol/L NaClO4 and 0.005-0.5 mol/L NaNO3 background electrolytes, respectively. Most of the experimental data were appropriately described by the model after we adjusted a single parameter (silanol sites on the surface of montmorillonite were made to be slightly more acidic than those of silica). At low ionic strength and acidic pH the model underestimated the buffering capacity of the montmorillonite, perhaps due to clay swelling or to the interlayer adsorption of dissolved aluminum. The agreement between our model and the experimental

  18. Sitewide feasibility study Eielson Air Force Base, Alaska

    Energy Technology Data Exchange (ETDEWEB)

    Last, G.V.; Lanigan, D.C.; Josephson, G.B.; Bagaasen, L.M.

    1995-09-01

    The Sitewide Feasibility Study (FS) is required under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA), the National Contingency Plan (NCP), and the Federal Facility Agreement (FFA) for Eielson Air Force Base (AFB). It is based on findings presented in the Sitewide Remedial Investigation (RI) Report (USAF 1995a), and the Sitewide Baseline Risk Assessment (BLRA) Report (USAF 1995b). Under the FFA, 64 potential source areas were placed in one of six operable units, based on similar contaminant and environmental characteristics, or were included for evaluation under a Source Evaluation Report (SER). The sitewide RI was directed at contamination that was not confined to an operable unit (OU) or SER source area. The objectives of the sitewide RI were to: Provide information about site characteristics to support individual OU RI/FS efforts and the sitewide RI/FS, including site hydrogeology and determination of background soil and groundwater characteristics; identify and characterize contamination that is not confined or attributable to a specific source area through sitewide monitoring of groundwater and surface water; evaluate cumulative risks to human health and the environment from contamination on a sitewide basis; and provide a mechanism for continued cohesive sitewide monitoring.

  19. [Research on determination of chemical purity of andrographolide by coulometric titration method].

    Science.gov (United States)

    Yang, Ning; Yang, Dezhi; Xu, Lishen; Lv, Yang

    2010-04-01

    The determination of chemical purity of andrographolide by coulometric titration method is studied in this paper. The coulometric titration was carried out in a mixture composed of 4 mol x L(-1) hydrochloric acid and 1 mol x L(-1) potassium bromide solution and 1 mol x L(-1) potassium nitrate solution (1:1). Bromine is electrogenerated at the anode and reacts with the andrographolide. The number of electrons involved in the eleatrode reaction is 2. Purity of andrographolide is 99.76% compared with 99.77% utilizing area normalization method by HPLC. The RSD are 0.33% and 0.02% respectively. The results from two methods are consistent, so the determination of chemical purity of andrographolide by coulometric titration method is scientific and feasible. The method is rapid, simple, convenient, sensitive and accurate. The reference material is not essential in the method. The method is suitable for determination of chemical purity of andrographolide.

  20. Thermometric titration of thorium with EDTA in the presence of large excess of neutral sodium salts

    International Nuclear Information System (INIS)

    Doi, K.

    1980-01-01

    The thermometric titration of Th(IV) in the presence of neutral sodium salts, sulphuric acid or acetic acid with EDT has been studied. The effect of each on the observed heat values for the titration is discussed. For sodium perchlorate media, ΔH values of -9 and -21 kJ/mole have been estimated for the formation of the Th(IV)-EDTA chelate at μ → 0 and μ = 0.5 (NaClO 4 ), respectively. The -ΔH values increase steadily with increase in concentration of sodium perchlorate up to at least 3M. For the titration of Th(IV) in the presence of a large excess of sodium nitrate the use of sodium iodide as a masking reagent has been examined: large amounts of Bi and Cu(II) are masked and a masking effect is observed for small amounts of Ni. (author)

  1. Thermometric titration of thorium with EDTA in the presence of large excess of neutral sodium salts.

    Science.gov (United States)

    Doi, K

    1980-11-01

    The thermometric titration of Th(IV) in the presence of neutral sodium salts, sulphuric acid or acetic acid with EDTA has been studied. The effect of each on the observed heat values for the titration is discussed. For sodium perchlorate media, DeltaH values of -9 and -21 kJ/mole have been estimated for the formation of the Th(IV)-EDTA chelate at mu --> 0 and mu = 0.5 (NaClO(4)), respectively. The -DeltaH values increase steadily with increase in concentration of sodium perchlorate up to at least 3M. For the titration of Th(IV) in the presence of a large excess of sodium nitrate the use of sodium iodide as a masking reagent has been examined: large amounts of Bi and Cu(II) are masked and a masking effect is observed for small amounts of Ni.

  2. Potentiometric titrations of para and nitro substituted aromatic acids and their mixtures in methylethyl ketone

    International Nuclear Information System (INIS)

    Ozeroglu, C.; Karahan, M.

    2011-01-01

    In this study, it was the purpose to examine the potentiometric titrations of para and nitro substituted aromatic acids in methylethyl ketone (MEK) as a non-aqueous solvent. Good analytical results were obtained in determining the amount of each acid and the amounts of acids in their ternary mixtures by using 0.0964 N tetrabuthylammoniumhydroxyde (TBAH) as a standard titrant. Methylethyl ketone (MEK) which is a good solvent for many organic compounds and has a convenient liquid range of -86 to 80 deg. C was used for titration of the para and nitro substituted aromatic acids. A linear relationship has been found between pKa values of the para and nitro substituted aromatic acids in water and the half neutralization potential (HNP) values determined by potentiometric titration curves of the same acids in MEK. (author)

  3. On the theory of thermometric titration.

    Science.gov (United States)

    Piloyan, G O; Dolinina, Y V

    1974-09-01

    The general equation defining the change in solution temperature DeltaT during a thermometric titration is DeltaT = T - T(0) = - AV 1 + BV where A and B are constants, V is the volume of titrant used to produce temperature T, and T(0) is the initial temperature. There is a linear relation between the inverse values of DeltaT and V: 1 Delta T = - a V - b where a = 1/A and b = B/A, both a and b being constants. A linear relation between DeltaT and V is usually a special case of this general relation, and is valid only over a narrow range of V. Graphs of 1/DeltaTvs. 1/V are more suitable for practical calculations than the usual graphs of DeltaTvs. V.

  4. A scalable platform for biomechanical studies of tissue cutting forces

    International Nuclear Information System (INIS)

    Valdastri, P; Tognarelli, S; Menciassi, A; Dario, P

    2009-01-01

    This paper presents a novel and scalable experimental platform for biomechanical analysis of tissue cutting that exploits a triaxial force-sensitive scalpel and a high resolution vision system. Real-time measurements of cutting forces can be used simultaneously with accurate visual information in order to extract important biomechanical clues in real time that would aid the surgeon during minimally invasive intervention in preserving healthy tissues. Furthermore, the in vivo data gathered can be used for modeling the viscoelastic behavior of soft tissues, which is an important issue in surgical simulator development. Thanks to a modular approach, this platform can be scaled down, thus enabling in vivo real-time robotic applications. Several cutting experiments were conducted with soft porcine tissues (lung, liver and kidney) chosen as ideal candidates for biopsy procedures. The cutting force curves show repeated self-similar units of localized loading followed by unloading. With regards to tissue properties, the depth of cut plays a significant role in the magnitude of the cutting force acting on the blade. Image processing techniques and dedicated algorithms were used to outline the surface of the tissues and estimate the time variation of the depth of cut. The depth of cut was finally used to obtain the normalized cutting force, thus allowing comparative biomechanical analysis

  5. Determination of acid–base properties of HCl acid activated palygorskite by Potentiometrie titration

    OpenAIRE

    N. FriniSrasra; E.Srasra

    2008-01-01

    The surface acidity of raw and acid activated palygorskite clay were studied by acid-base potentiometric titration. The Gran plot method was applied for the hydroxide titration and the total surface site (Hs) and the average number of protons reacted per surface site (Z) of palygorskite samples at a given ionic strength were calculated. Acid treatment increases the clay acidity and modifies its surface charge. The point of zero charge value, determined by the common crossing point of Z vs pH ...

  6. Analysis of the Purity of Cetrimide by Titrations

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov; Rasmussen, Claus/Dallerup; Nielsen, Hans/Boye

    2006-01-01

    . Titration by perchloric acid showed a 99.69 ± 0.05 % purity of cetrimide and titration by silver nitrate showed a 99.85% ± 0.05 % purity while the traditional assay method predicted a purity of only 97.1 ± 0.4. It was found that the discrepancy could be identified as differences in selectivity during...

  7. A Closer Look at Acid-Base Olfactory Titrations

    Science.gov (United States)

    Neppel, Kerry; Oliver-Hoyo, Maria T.; Queen, Connie; Reed, Nicole

    2005-01-01

    Olfactory titrations using raw onions and eugenol as acid-base indicators are reported. An in-depth investigation on olfactory titrations is presented to include requirements for potential olfactory indicators and protocols for using garlic, onions, and vanillin as acid-base olfactory indicators are tested.

  8. New applications of corrosion measurements by titration (CMT)

    DEFF Research Database (Denmark)

    Bech-Nielsen, Gregers

    1998-01-01

    . It is shown that when aluminium dissolves in alkali, CMT measurements can also be applied, but in this case requiring titration with alkali. Titration with alkali is also required in a special situation, where corrosion of nickel in an acid solution and subsequent formation of a nickel complex results...

  9. The coulometric titration of acids and bases in dimethylsulfoxide media

    NARCIS (Netherlands)

    Bos, M.; IJpma, S.T.; Dahmen, E.A.M.F.

    1976-01-01

    The coulometric titration of 20–200 μeq of acids and bases in DMSO media is described. In the titration of bases, the electro-oxidation of hydrogen at a platinized platinum electrode is used as the source of protons. The conditions for 100 % current efficiency at this electrode are low current

  10. Determination of the protonation enthalpy of humic acid by calorimetric titration technique

    International Nuclear Information System (INIS)

    Kimuro, Shingo; Kirishima, Akira; Sato, Nobuaki

    2015-01-01

    Graphical abstract: The thermodynamic quantities of protonation of humic acid were determined by the combination of potentiometric titration and calorimetric titration. It was observed that the protonation enthalpy and Gibbs free energy had been affected by pH of solution. As a result, the thermodynamics of the protonation reaction of humic acid is influenced by the polyelectrolyte effect and the heterogeneity. - Highlights: • We applied calorimetric titration technique to the protonation of humic acid. • The thermodynamic quantities of protonation of humic acid were determined. • The protonation enthalpy of humic acid is affected by the heterogeneity. • Gibbs free energy of the protonation is affected by the polyelectrolyte effect. - Abstract: In this study, the calorimetric titration technique was used to determine the protonation enthalpy of two reference humic acids and polyacrylic acid. First, we obtained the apparent protonation constant of two kinds of humic acid purchased from IHSS (International Humic Substances Society) and polyacrylic acid by potentiometric titration. Second, we obtained the protonation enthalpy of them by calorimetric titration. The protonation enthalpy of humic acid was affected by pH and the ionic strength of bulk solution. From the comparison of ΔH between humic acid and polyacrylic acid, it was concluded that the pH dependence of ΔH is attributed to the heterogeneity of humic acid. And ΔH of phenolic hydroxyl group in humic acid is strongly influenced by the electric double layer of humic acid’s surface. This is considered to be a reason of the ionic strength dependence of ΔH. On the other hand, Gibbs free energy of the protonation of humic acid is affected by the electrostatic attraction with the progress of dissociation of functional groups such as carboxyl group and phenolic hydroxyl group. Consequently, the thermodynamics of the protonation of humic acid is affected by the polyelectrolyte effect and the

  11. Attractive forces study in macromolecules and critical systems; Etude des forces attractives dans les macromolecules et les systemes critiques

    Energy Technology Data Exchange (ETDEWEB)

    Penninckx-Sans, A.

    1995-07-10

    The attractive forces effect is particularly interesting at the proximity of a critical point. In a liquid system, there are two kinds of attractive forces in presence : the forces bound to the solution volume and those generated by the presence of the solution surface or by a solution interface. In the first case, the attractive forces are the more important as the system is in a critical field. For this study, the selected example is a polymer solution in a two solvents mixture. A formulation in terms of way integrals as part of statistical physics has lead us to find again some known results on the polymer chain conformation in the presence of two solvents (collapse of the polymer on itself) far from the critical point and to extend these results to the critical field. In the case of attractive forces created by the surface in some critical systems (polymer of infinite size in solution and binary mixture near the de mixture point), the adsorption profile created by the attraction of one specie by the surface, follows a scale law. The optical methods usually used for the study of these systems do not give characteristic sign of concentration profile in power law. In the case where the interaction potential between radiation and matter is attractive, the reflectivity gives a separate mark of the existence of the scale law in the form of a resonance. After some theoretical forecasts, the author has used this method on the binary mixture methanol-cyclohexane in order to reveal experimentally a reflectivity pseudo-discontinuity and then the existence of the power law in the critical adsorption profile. (O.L.). 69 refs., 60 tabs.

  12. Synchronizing atomic force microscopy force mode and fluorescence microscopy in real time for immune cell stimulation and activation studies

    Energy Technology Data Exchange (ETDEWEB)

    Cazaux, Séverine; Sadoun, Anaïs; Biarnes-Pelicot, Martine; Martinez, Manuel; Obeid, Sameh [Aix Marseille Université, LAI UM 61, Marseille F-13288 (France); Inserm, UMR-S 1067, Marseille F-13288 (France); CNRS, UMR 7333, Marseille F-13288 (France); Bongrand, Pierre [Aix Marseille Université, LAI UM 61, Marseille F-13288 (France); Inserm, UMR-S 1067, Marseille F-13288 (France); CNRS, UMR 7333, Marseille F-13288 (France); APHM, Hôpital de la Conception, Laboratoire d’Immunologie, Marseille F-13385 (France); Limozin, Laurent [Aix Marseille Université, LAI UM 61, Marseille F-13288 (France); Inserm, UMR-S 1067, Marseille F-13288 (France); CNRS, UMR 7333, Marseille F-13288 (France); Puech, Pierre-Henri, E-mail: pierre-henri.puech@inserm.fr [Aix Marseille Université, LAI UM 61, Marseille F-13288 (France); Inserm, UMR-S 1067, Marseille F-13288 (France); CNRS, UMR 7333, Marseille F-13288 (France)

    2016-01-15

    A method is presented for combining atomic force microscopy (AFM) force mode and fluorescence microscopy in order to (a) mechanically stimulate immune cells while recording the subsequent activation under the form of calcium pulses, and (b) observe the mechanical response of a cell upon photoactivation of a small G protein, namely Rac. Using commercial set-ups and a robust signal coupling the fluorescence excitation light and the cantilever bending, the applied force and activation signals were very easily synchronized. This approach allows to control the entire mechanical history of a single cell up to its activation and response down to a few hundreds of milliseconds, and can be extended with very minimal adaptations to other cellular systems where mechanotransduction is studied, using either purely mechanical stimuli or via a surface bound specific ligand. - Highlights: • A signal coupling AFM and fluorescence microscopy was characterized for soft cantilevers. • It can be used as an intrinsic timer to synchronize images and forces. • Mechanical stimulation of single immune cells while recording calcium fluxes was detailed. • Light-induced mechanical modifications of lymphocytes using a PA-Rac protein were demonstrated. • The precautions and limitations of use of this effect were presented.

  13. Conductimetric and Potentiometric Titration of Some Hydroxylated Cinnamic Acids with Tetrabutylammonium Hydroxide in Non-Aqueous Media

    OpenAIRE

    AKTAŞ, A. Hakan; YAŞAR, Gülsüm; ALSANCAK, Güleren ÖZKAN

    2001-01-01

    In this study, four hydroxycinnamic acids, namely 3,4-dihydroxycinnamic acid, 4-hydroxycinnamic acid, 4-hydroxy --3- methoxycinnamic acid and 4-hydroxy-3,5-dimethoxycinnamic acid, were titrated conductimetrically and potentiometrically using triethylamine and tetrabutylammonium hydroxide in acetonitrile, 2-propanol, and pyridine solvents under a nitrogen atmosphere at 25 oC. In conductimetric titration with tetrabutylammonium hydroxide all of the compounds exhibited conventional s...

  14. A generalized approach for the calculation and automation of potentiometric titrations Part 1. Acid-Base Titrations

    NARCIS (Netherlands)

    Stur, J.; Bos, M.; van der Linden, W.E.

    1984-01-01

    Fast and accurate calculation procedures for pH and redox potentials are required for optimum control of automatic titrations. The procedure suggested is based on a three-dimensional titration curve V = f(pH, redox potential). All possible interactions between species in the solution, e.g., changes

  15. Surface adhesion properties of graphene and graphene oxide studied by colloid-probe atomic force microscopy

    International Nuclear Information System (INIS)

    Ding Yanhuai; Zhang Ping; Ren Huming; Zhuo Qin; Yang Zhongmei; Jiang Xu; Jiang Yong

    2011-01-01

    Surface adhesion properties are important to various applications of graphene-based materials. Atomic force microscopy is powerful to study the adhesion properties of samples by measuring the forces on the colloidal sphere tip as it approaches and retracts from the surface. In this paper we have measured the adhesion force between the colloid probe and the surface of graphene (graphene oxide) nanosheet. The results revealed that the adhesion force on graphene and graphene oxide surface were 66.3 and 170.6 nN, respectively. It was found the adhesion force was mainly determined by the water meniscus, which was related to the surface contact angle of samples.

  16. IMPEDANCE METHOD OF MEASURING OF THE TITRATABLE ACIDITY OF YOGURT

    Directory of Open Access Journals (Sweden)

    Miroslav Vasilev

    2016-10-01

    Full Text Available In the present work are analyzed studies related to changes in the active impedance component of the dairy environment caused by the flow of lactic fermentation and coagulation of casein in milk. The aim of this work was to determine the relationship between the relative change of titratable acidity and the relative change of active impedance component of the dairy environment with lactic fermentation, causing coagulation of the casein in milk. . The data were interpolated with cubic spline, visualizing how when the fat content increases, the electrical resistance increases too. All data, collected during the tests would complement and be used for solving the optimization problem to determine the time of completion of the coagulation in future work.

  17. 76 FR 21383 - Proposed Collection; Comment Request; Food Reporting Comparison Study (FORCS) and Food and Eating...

    Science.gov (United States)

    2011-04-15

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health Proposed Collection; Comment Request; Food Reporting Comparison Study (FORCS) and Food and Eating Assessment Study (FEAST) (NCI... Collection: Title: Food Reporting Comparison Study (FORCS) and Food and Eating Assessment Study (FEAST) (NCI...

  18. Titration effectiveness of two autoadjustable continuous positive airway pressure devices driven by different algorithms in patients with obstructive sleep apnoea.

    Science.gov (United States)

    Damiani, Mario Francesco; Quaranta, Vitaliano Nicola; Tedeschi, Ersilia; Drigo, Riccardo; Ranieri, Teresa; Carratù, Pierluigi; Resta, Onofrio

    2013-08-01

    Nocturnal application of continuous positive airway pressure (CPAP) is the standard treatment for patients with obstructive sleep apnoea (OSA). Determination of the therapeutic pressure (CPAP titration) is usually performed by a technician in the sleep laboratory during attended polysomnography. One possible alternative to manual titration is automated titration. Indeed, during the last 15 years, devices have been developed that deliver autoadjustable CPAP (A-CPAP). The aim of the present study was to compare the titration effectiveness of two A-CPAP devices using different flow-based algorithms in patients with OSA. This is a randomized study; 79 subjects underwent two consecutive unattended home A-CPAP titration nights with two different devices (Autoset Resmed; Remstar Auto Respironics); during the third and the fourth night, patients underwent portable monitoring in the sleep laboratory during fixed CPAP at the A-CPAP recommended pressure. Bland Altman plots showed good agreement between the recommended median and maximal pressure levels obtained with the two devices. A significant improvement was observed in all the sleep parameters by both A-CPAP machines to a similar degree. It was observed that the two A-CPAP devices using different algorithms are equally effective in initial titration of CPAP. © 2013 The Authors. Respirology © 2013 Asian Pacific Society of Respirology.

  19. In situ electrochemical atomic force microscope study on graphite electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Hirasawa, K.A.; Sato, Tomohiro; Asahina, Hitoshi; Yamaguchi, Shoji; Mori, Shoichiro [Mitsubishi Chemical Corp., Inashiki, Ibaraki (Japan). Tsukuba Research Center

    1997-04-01

    Interest in the formation of the solid electrolyte interphase (SEI) film on graphite electrodes has increased recently in the quest to improve the performance of lithium-ion batteries. Topographic and frictional changes on the surface of a highly oriented pyrolytic graphite electrode in 1 M LiCiO{sub 4} ethylene carbonate/ethylmethyl carbonate (1:1) electrolyte were examined during charge and discharge by in situ electrochemical atomic force microscopy and friction force microscopy simultaneously in real-time. Solid electrolyte interphase film formation commenced at approximately 2 V vs. Li/Li{sup +} and stable film formation with an island-like morphology was observed below approximately 0.9 V vs. Li/Li{sup +}. Further experiments on a KS-44 graphite/polyvinylidene difluoride binder composite electrode showed similar phenomena.

  20. pH and Titratable Acidity of different Cough Syrups in Nigeria ...

    African Journals Online (AJOL)

    Background: Cough linctuses are liquid oral medicines widely used in children to treat cough and related conditions. Some of their constituents are acidic and dental erosive. Objectives: This in vitro study aimed to evaluate the endogenous pH and titratable acidity of Nigerian cough syrups and also determine their erosive ...

  1. Non-euclidean simplex optimization. [Application to potentiometric titration of Pu

    Energy Technology Data Exchange (ETDEWEB)

    Silver, G.L.

    1977-08-15

    Geometric optimization techniques useful for studying chemical equilibrium traditionally rely upon principles of euclidean geometry, but such algorithms may also be based upon principles of a non-euclidean geometry. The sequential simplex method is adapted to the hyperbolic plane, and application of optimization to problems such as the potentiometric titration of plutonium is suggested.

  2. Titration and HPLC Characterization of Kombucha Fermentation: A Laboratory Experiment in Food Analysis

    Science.gov (United States)

    Miranda, Breanna; Lawton, Nicole M.; Tachibana, Sean R.; Swartz, Natasja A.; Hall, W. Paige

    2016-01-01

    Quantification of the many constituents that make up our food, whether they are desirable (vitamins, antioxidants, nutrients) or undesirable (pesticides, toxins), is one of the most practical applications of chemistry. In this study, kombucha, a popular fermented tea beverage, was analyzed using acid-base titration and high-performance liquid…

  3. Thermodynamic analysis of Bacillus subtilis endospore protonation using isothermal titration calorimetry

    Science.gov (United States)

    Harrold, Zoë R.; Gorman-Lewis, Drew

    2013-05-01

    Bacterial proton and metal adsorption reactions have the capacity to affect metal speciation and transport in aqueous environments. We coupled potentiometric titration and isothermal titration calorimetry (ITC) analyses to study Bacillus subtilis spore-proton adsorption. We modeled the potentiometric data using a four and five-site non-electrostatic surface complexation model (NE-SCM). Heats of spore surface protonation from coupled ITC analyses were used to determine site specific enthalpies of protonation based on NE-SCMs. The five-site model resulted in a substantially better model fit for the heats of protonation but did not significantly improve the potentiometric titration model fit. The improvement observed in the five-site protonation heat model suggests the presence of a highly exothermic protonation reaction circa pH 7 that cannot be resolved in the less sensitive potentiometric data. From the log Ks and enthalpies we calculated corresponding site specific entropies. Log Ks and site concentrations describing spore surface protonation are statistically equivalent to B. subtilis cell surface protonation constants. Spore surface protonation enthalpies, however, are more exothermic relative to cell based adsorption suggesting a different bonding environment. The thermodynamic parameters defined in this study provide insight on molecular scale spore-surface protonation reactions. Coupled ITC and potentiometric titrations can reveal highly exothermic, and possibly endothermic, adsorption reactions that are overshadowed in potentiometric models alone. Spore-proton adsorption NE-SCMs derived in this study provide a framework for future metal adsorption studies.

  4. Effects of pH, titratable acidity and calcium concentration of non ...

    African Journals Online (AJOL)

    It has also been reported that experimental addition of calcium in beverages can reduce the progression of erosion. This study was carried out to investigate effects the of pH, titratable acidity and calcium concentration of non alcoholic carbonated beverages on enamel erosion of extracted human premolar teeth. Method: ...

  5. The Mobile Insulin Titration Intervention (MITI) for Insulin Glargine Titration in an Urban, Low-Income Population: Randomized Controlled Trial Protocol.

    Science.gov (United States)

    Levy, Natalie; Moynihan, Victoria; Nilo, Annielyn; Singer, Karyn; Bernik, Lidia S; Etiebet, Mary-Ann; Fang, Yixin; Cho, James; Natarajan, Sundar

    2015-03-13

    Patients on insulin glargine typically visit a clinician to obtain advice on how to adjust their insulin dose. These multiple clinic visits can be costly and time-consuming, particularly for low-income patients. It may be feasible to achieve insulin titration through text messages and phone calls with patients instead of face-to-face clinic visits. The objectives of this study are to (1) evaluate if the Mobile Insulin Titration Intervention (MITI) is clinically effective by helping patients reach their optimal dose of insulin glargine, (2) determine if the intervention is feasible within the setting and population, (3) assess patient satisfaction with the intervention, and (4) measure the costs associated with this intervention. This is a pilot study evaluating an approach to insulin titration using text messages and phone calls among patients with insulin-dependent type 2 diabetes in the outpatient medical clinic of Bellevue Hospital Center, a safety-net hospital in New York City. Patients will be randomized in a 1:1 ratio to either the MITI arm (texting/phone call intervention) or the usual-care arm (in-person clinic visits). Using a Web-based platform, weekday text messages will be sent to patients in the MITI arm, asking them to text back their fasting blood glucose values. In addition to daily reviews for alarm values, a clinician will rereview the texted values weekly, consult our physician-approved titration algorithm, and call the patients with advice on how to adjust their insulin dose. The primary outcome will be whether or not a patient reaches his/her optimal dose of insulin glargine within 12 weeks. Recruitment for this study occurred between June 2013 and December 2014. We are continuing to collect intervention and follow-up data from our patients who are currently enrolled. The results of our data analysis are expected to be available in 2015. This study explores the use of widely-available text messaging and voice technologies for insulin titration

  6. Atomic Force Microscopy Application in Biological Research: A Review Study

    Directory of Open Access Journals (Sweden)

    Surena Vahabi

    2013-06-01

    Full Text Available Atomic force microscopy (AFM is a three-dimensional topographic technique with a high atomic resolution to measure surface roughness. AFM is a kind of scanning probe microscope, and its near-field technique is based on the interaction between a sharp tip and the atoms of the sample surface. There are several methods and many ways to modify the tip of the AFM to investigate surface properties, including measuring friction, adhesion forces and viscoelastic properties as well as determining the Young modulus and imaging magnetic or electrostatic properties. The AFM technique can analyze any kind of samples such as polymers, adsorbed molecules, films or fibers, and powders in the air whether in a controlled atmosphere or in a liquid medium. In the past decade, the AFM has emerged as a powerful tool to obtain the nanostructural details and biomechanical properties of biological samples, including biomolecules and cells. The AFM applications, techniques, and -in particular- its ability to measure forces, are not still familiar to most clinicians. This paper reviews the literature on the main principles of the AFM modality and highlights the advantages of this technique in biology, medicine, and- especially- dentistry. This literature review was performed through E-resources, including Science Direct, PubMed, Blackwell Synergy, Embase, Elsevier, and Scholar Google for the references published between 1985 and 2010.

  7. Study on electromagnetism force of CARR control rod drive mechanism experimental machine

    International Nuclear Information System (INIS)

    Zhu Xuewei; Zhen Jianxiao; Wang Yulin; Jia Yueguang; Yang Kun; Yin Haozhe

    2015-01-01

    With the aim of acquiring electromagnetic force and electromagnetic field distributions of control rod drive mechanism (CRDM) in China Advanced Research Reactor (CARR), the force analysis on the CRDM was taken. Manufacturing the experimental machine, the electromagnetic force experiment was taken on it. The electromagnetic field and electromagnetic force simulation analyses of experimental machine were taken, working out distribution data of electromagnetic force and magnetic induction intensity distribution curve, and the effects of permanent magnetic field on electromagnetic field and structure parameters on electromagnetic force. The simulation value is accord with experiment value, the research results provide a reference to electromagnetic force study on CRDM in CARR, and also provide a reference to design of the same type CRDM. (authors)

  8. Evaluation of the 5 and 8 pH point titration methods for monitoring anaerobic digesters treating solid waste.

    Science.gov (United States)

    Vannecke, T P W; Lampens, D R A; Ekama, G A; Volcke, E I P

    2015-01-01

    Simple titration methods certainly deserve consideration for on-site routine monitoring of volatile fatty acid (VFA) concentration and alkalinity during anaerobic digestion (AD), because of their simplicity, speed and cost-effectiveness. In this study, the 5 and 8 pH point titration methods for measuring the VFA concentration and carbonate system alkalinity (H2CO3*-alkalinity) were assessed and compared. For this purpose, synthetic solutions with known H2CO3*-alkalinity and VFA concentration as well as samples from anaerobic digesters treating three different kind of solid wastes were analysed. The results of these two related titration methods were verified with photometric and high-pressure liquid chromatography measurements. It was shown that photometric measurements lead to overestimations of the VFA concentration in the case of coloured samples. In contrast, the 5 pH point titration method provides an accurate estimation of the VFA concentration, clearly corresponding with the true value. Concerning the H2CO3*-alkalinity, the most accurate and precise estimations, showing very similar results for repeated measurements, were obtained using the 8 pH point titration. Overall, it was concluded that the 5 pH point titration method is the preferred method for the practical monitoring of AD of solid wastes due to its robustness, cost efficiency and user-friendliness.

  9. Force decay of elastomeric chains - a mechanical design and product comparison study.

    Science.gov (United States)

    Balhoff, David A; Shuldberg, Matthew; Hagan, Joseph L; Ballard, Richard W; Armbruster, Paul C

    2011-03-01

    To evaluate the percentage force decay of elastomeric chain products utilizing three different design mechanisms simulating canine retraction; and to evaluate the percentage force decay of elastomeric chain products from four different companies. In vitro, laboratory study. LSUHSC Dental School, New Orleans, LA, USA. Closed (non-spaced), grey elastomeric chains from four companies were selected for the study. Three acrylic resin jigs were constructed to provide a framework for three simulated space closure mechanisms. The 6-5-3, the chain loop, and the 6-3 were the configuration mechanisms used in the study. An electronic force gauge was used to measure the percentage force decay associated with each elastomeric chain over 28 days at preselected times. There was a significant difference in the mean percentage force decay for the three different mechanisms (P < 0·001). For all four companies, the 6-3 mechanical design had the smallest mean percentage force decay. There was a significant difference in the mean percentage force decay for the different companies (P < 0·001). For all three mechanisms, Ormco had the smallest percentage force decay while Unitek had the highest percentage force decay. The significant difference in the mean percentage force decay for the different mechanisms suggests that the 6-3 design is a more efficient means of closing extraction spaces utilizing elastomeric chains.

  10. Novel titration method for surface-functionalised silica

    Energy Technology Data Exchange (ETDEWEB)

    Hofen, Kai; Weber, Siegfried [Department of Biotechnology, University of Applied Sciences, Mannheim (Germany); Chan, Chiu Ping Candace [School of Advanced Manufacturing and Mechanical Engineering, Mawson Institute, University of South Australia, Mawson Lakes Blvd, Mawson Lakes 5095 (Australia); Majewski, Peter, E-mail: peter.majewski@unisa.edu.au [School of Advanced Manufacturing and Mechanical Engineering, Mawson Institute, University of South Australia, Mawson Lakes Blvd, Mawson Lakes 5095 (Australia)

    2011-01-15

    This paper describes three inexpensive and fast analytical methods to characterise grafted particle surfaces. The reaction of silica with (3-aminopropyl)triethoxysilane, (3-mercaptopropyl)trimethoxysilane and N-(phosphonomethyl)iminodiacetic acid hydrate, respectively, leads to NH{sub 2}-, SO{sub 3}H- or COOH-functionalised silica, which were characterised by X-ray photoelectron spectrometry and titration in nonaqueous media as well as with two titration methods in a water-based environment. In the work presented, factors influencing the titrations are pointed out and solutions are presented to overcome these limiting factors are shown.

  11. Novel titration method for surface-functionalised silica

    International Nuclear Information System (INIS)

    Hofen, Kai; Weber, Siegfried; Chan, Chiu Ping Candace; Majewski, Peter

    2011-01-01

    This paper describes three inexpensive and fast analytical methods to characterise grafted particle surfaces. The reaction of silica with (3-aminopropyl)triethoxysilane, (3-mercaptopropyl)trimethoxysilane and N-(phosphonomethyl)iminodiacetic acid hydrate, respectively, leads to NH 2 -, SO 3 H- or COOH-functionalised silica, which were characterised by X-ray photoelectron spectrometry and titration in nonaqueous media as well as with two titration methods in a water-based environment. In the work presented, factors influencing the titrations are pointed out and solutions are presented to overcome these limiting factors are shown.

  12. The fluorimetric titration of zirconium in the ppm-range

    International Nuclear Information System (INIS)

    Linden, W.E. von der; Boef, G. den; Ozinga, W.

    1976-01-01

    A fluorimetric titration of zirconium(IV) with EDTA is proposed. The fluorescence intensity of the zirconium-morin complex is used to indicate the end-point. More than twenty other cations were investigated and it was found that they did not interfere, neither did common anions. Mercury(II) can only be tolerated in amount not exceeding that of zirconium. Bismuth(III) interferes and hafnium(IV0 is titrated together with zirconium. The relative standard deviation of the titration of 10ml of a solution containing 1 ppm of zirconium does not exceed 1.5%

  13. Determination of boron as boric acid by automatic potentiometric titration

    International Nuclear Information System (INIS)

    Midgley, D.

    1988-06-01

    Boron in PWR primary coolant and related waters may be determined as boric acid by titration with sodium hydroxide, using a glass electrode as a pH indicator. With a modern automatic titrator, the analysis is quick, convenient, accurate and precise. In the titration of 8 mg B (e.g. 4 ml of 2000 mg 1 -1 solution), no significant bias was observed and relative standard deviations were about 0.25%. With 0.8 g B, a bias of about 2% appears, although this could be reduced by restandardizing the titrant, but the relative standard deviation was still -1 B, depending on the stage of the fuel cycle. (author)

  14. The Potentiometric Titration of Filtrates from the Bachmann Process

    Science.gov (United States)

    1942-06-23

    SCIENTIFIC RESEARCH AND DEVELOP11ENT The Potentiometric Titration of Filtrates from the Bachmann Process (OD-12) by F. C. Whitmore OSRD No. 654... Potentiometric Titration of Synthetic Mixtures. A? Nitric Acid-Acetic Acid. A sample of 60 ml. glacial acetic acid war diluted to 200 ml. with distilled...i4flinflr?fj3 TADLE 1 CO) |S?lDBnTl» POTENTIOMETRIC TITRATION OF SYNTHETIC t’.IXTURES WITH CONCENTRATED AJKDNIUM HYDROXIDE A; unonium HNO-j- AcOfi Ky

  15. Vandenberg Air Force Base Pressure Gradient Wind Study

    Science.gov (United States)

    Shafer, Jaclyn A.

    2013-01-01

    Warning category winds can adversely impact day-to-day space lift operations at Vandenberg Air Force Base (VAFB) in California. NASA's Launch Services Program and other programs at VAFB use wind forecasts issued by the 30 Operational Support Squadron Weather Flight (30 OSSWF) to determine if they need to limit activities or protect property such as a launch vehicle. The 30 OSSWF tasked the AMU to develop an automated Excel graphical user interface that includes pressure gradient thresholds between specific observing stations under different synoptic regimes to aid forecasters when issuing wind warnings. This required the AMU to determine if relationships between the variables existed.

  16. A study on the force balance of an unbalanced globe valve

    International Nuclear Information System (INIS)

    Yang, Sang Min; Cho, Taik Dong; Ko, Sung Ho; Lee, Ho Young

    2007-01-01

    A pneumatic control valve is a piping element that controls the volumetric flow rate and pressure of a fluid: it is necessary to analyze the characteristics of the forces with respect to the opening of the valve in order to evaluate its operating performance. The forces occurring during operation are: resisting force and actuator force, where the load resistance is mostly affected by the fluid pressure difference of the valve. In this study, a force balance equation derived from the equilibrium relationship between the resisting force and the actuator force of an unbalanced globe valve is proposed, and the force balance equations are used to model the dynamic equations of a pneumatic unbalanced globe valve installed in nuclear power plants. A CFD analysis is also carried out to evaluate the pressure distribution and forces acting on the top and bottom planes of the valve plug. The results of this analysis have been verified through experimentation. This study has shown that the fluid pressure difference between the inlet and outlet of the valve, measured from the force balance equation of an unbalanced valve, should actually be examined with the fluid-pressure difference between the top and bottom side of the valve plug

  17. Switching From Age-Based Stimulus Dosing to Dose Titration Protocols in Electroconvulsive Therapy: Empirical Evidence for Better Patient Outcomes With Lower Peak and Cumulative Energy Doses.

    Science.gov (United States)

    O'Neill-Kerr, Alex; Yassin, Anhar; Rogers, Stephen; Cornish, Janie

    2017-09-01

    The aim of this study was to test the proposition that adoption of a dose titration protocol may be associated with better patient outcomes, at lower treatment dose, and with comparable cumulative dose to that in patients treated using an age-based stimulus dosing protocol. This was an analysis of data assembled from archived records and based on cohorts of patients treated respectively on an age-based stimulus dosing protocol and on a dose titration protocol in the National Health Service in England. We demonstrated a significantly better response in the patient cohort treated with dose titration than with age-based stimulus dosing. Peak doses were less and the total cumulative dose was less in the dose titration group than in the age-based stimulus dosing group. Our findings are consistent with superior outcomes in patients treated using a dose titration protocol when compared with age-based stimulus dosing in a similar cohort of patients.

  18. The possibility of determining the activity coefficients of individual ions from acid-base titration data

    Science.gov (United States)

    Jano, I.; Hardcastle, J. E.

    1998-07-01

    A method is described for obtaining the activity coefficients of individual ions from experimental titration data. For this purpose, a general polyprotic acid-base-titration-curve equation is derived. The equation allows obtaining the dissociation equilibrium constants of the acid and the ratio of the activity coefficient of each ion to the activity coefficient of the undissociated acid directly from the titration data. Results obtained are compared with coefficients calculated using Debye-Hückel equation. A general equation relating the ionic strength to the pH of the titration medium is also established. Une méthode pour l'obtention des coefficients d'activité des ions individuels à partir des données expérimentales de titrage est établie. À ce but, une équation générale est dérivée pour représenter la courbe de titrage d'un acide avec une base. Cette équation permet d'obtenir les constants d'équilibre de dissociation de l'acide et le rapport de coefficient d'activité de chaque ion au coefficient d'activité de l'acide non-dissocié à partir des données de titrage. Les résultats ainsi obtenus sont comparés avec les coefficients calculés à l'aide de l'équation de Debye-Hückel. Une équation liant la force ionique au pH du milieu est établie aussi.

  19. [Predictive methods versus clinical titration for the initiation of lithium therapy. A systematic review].

    Science.gov (United States)

    Geeraerts, I; Sienaert, P

    2013-01-01

    When lithium is administered, the clinician needs to know when the lithium in the patient’s blood has reached a therapeutic level. At the initiation of treatment the level is usually achieved gradually through the application of the titration method. In order to increase the efficacy of this procedure several methods for dosing lithium and for predicting lithium levels have been developed. To conduct a systematic review of the publications relating to the various methods for dosing lithium or predicting lithium levels at the initiation of therapy. We searched Medline systematically for articles published in English, French or Dutch between 1966 and April 2012 which described or studied a method for dosing lithium or for predicting the lithium level reached following a specific dosage. We screened the reference lists of relevant articles in order to locate additional papers. We found 38 lithium prediction methods, in addition to the clinical titration method. These methods can be divided into two categories: the ‘a priori’ methods and the ‘test-dose’ methods, the latter requiring the administration of a test dose of lithium. The lithium prediction methods generally achieve a therapeutic blood level faster than the clinical titration method, but none of the methods achieves convincing results. On the basis of our review, we propose that the titration method should be used as the standard method in clinical practice.

  20. Macromolecular competition titration method accessing thermodynamics of the unmodified macromolecule-ligand interactions through spectroscopic titrations of fluorescent analogs.

    Science.gov (United States)

    Bujalowski, Wlodzimierz; Jezewska, Maria J

    2011-01-01

    Analysis of thermodynamically rigorous binding isotherms provides fundamental information about the energetics of the ligand-macromolecule interactions and often an invaluable insight about the structure of the formed complexes. The Macromolecular Competition Titration (MCT) method enables one to quantitatively obtain interaction parameters of protein-nucleic acid interactions, which may not be available by other methods, particularly for the unmodified long polymer lattices and specific nucleic acid substrates, if the binding is not accompanied by adequate spectroscopic signal changes. The method can be applied using different fluorescent nucleic acids or fluorophores, although the etheno-derivatives of nucleic acid are especially suitable as they are relatively easy to prepare, have significant blue fluorescence, their excitation band lies far from the protein absorption spectrum, and the modification eliminates the possibility of base pairing with other nucleic acids. The MCT method is not limited to the specific size of the reference nucleic acid. Particularly, a simple analysis of the competition titration experiments is described in which the fluorescent, short fragment of nucleic acid, spanning the exact site-size of the protein-nucleic acid complex, and binding with only a 1:1 stoichiometry to the protein, is used as a reference macromolecule. Although the MCT method is predominantly discussed as applied to studying protein-nucleic acid interactions, it can generally be applied to any ligand-macromolecule system by monitoring the association reaction using the spectroscopic signal originating from the reference macromolecule in the presence of the competing macromolecule, whose interaction parameters with the ligand are to be determined. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. Macromolecular Competition Titration Method: Accessing Thermodynamics of the Unmodified Macromolecule–Ligand Interactions Through Spectroscopic Titrations of Fluorescent Analogs

    Science.gov (United States)

    Bujalowski, Wlodzimierz; Jezewska, Maria J.

    2011-01-01

    Analysis of thermodynamically rigorous binding isotherms provides fundamental information about the energetics of the ligand–macromolecule interactions and often an invaluable insight about the structure of the formed complexes. The Macromolecular Competition Titration (MCT) method enables one to quantitatively obtain interaction parameters of protein–nucleic acid interactions, which may not be available by other methods, particularly for the unmodified long polymer lattices and specific nucleic acid substrates, if the binding is not accompanied by adequate spectroscopic signal changes. The method can be applied using different fluorescent nucleic acids or fluorophores, although the etheno-derivatives of nucleic acid are especially suitable as they are relatively easy to prepare, have significant blue fluorescence, their excitation band lies far from the protein absorption spectrum, and the modification eliminates the possibility of base pairing with other nucleic acids. The MCT method is not limited to the specific size of the reference nucleic acid. Particularly, a simple analysis of the competition titration experiments is described in which the fluorescent, short fragment of nucleic acid, spanning the exact site-size of the protein–nucleic acid complex, and binding with only a 1:1 stoichiometry to the protein, is used as a reference macromolecule. Although the MCT method is predominantly discussed as applied to studying protein–nucleic acid interactions, it can generally be applied to any ligand–macromolecule system by monitoring the association reaction using the spectroscopic signal originating from the reference macromolecule in the presence of the competing macromolecule, whose interaction parameters with the ligand are to be determined. PMID:21195223

  2. Simple home-made sensors for potentiometric titrations

    International Nuclear Information System (INIS)

    Selig, W.

    1982-04-01

    A sensor for potentiometric titrations was prepared by coating a spectroscopic graphite rod with a solution of poly(vinyl chloride) and dioctyphthalate in tetrahydrofuran. The reference electrode was an Ag/AgCl single-junction electrode. The sensor was used in precipitation, acid-base, compleximetric, and redox titrations. Preparation of the coated-graphite sensor is simple and rapid. Moreover, it is quite inexpensive. A limitation is its applicability in aqueous media only, because organic solvents will dissolve the membrane. Various uncoated types of graphite have also been investigated as sensors, particularly in two applications of interest in the analysis of propellants: the titration of nitroform and perchlorate. Obviously, these sensors can be used also in nonaqueous, or partially nonaqueous media. These sensors may also find use in the potentiometric titration of fluoride vs La(III) or Th

  3. Spectrophotometric titration of sulfates in the presence of zirconium

    International Nuclear Information System (INIS)

    Kuznetsov, V.V.; Kotova, S.S.; Molokanova, L.G.; Chekmarev, A.M.; Yagodin, G.A.

    1978-01-01

    The procedure has been proposed for express determination of sulphate ions in the presence of zirconium by spectrophotometric titration with the use of barium chloride and nitrochromazo as an indicator. The procedure is based on bonding zirconium into a more stable complex with EDTA (ethylenediaminotetraacetic acid). The presence of excess of EDTA and zirconium (4) complexonate in the solution being titrated does not affect the titration curve shape and the character of break on the curve in the equivalence point. A complete demasking of SO 4 2- is observed in the case of 1O-fold excess of EDTA with respect to zirconium (4). Statistic evaluation of the method has shown that the results of titration can be distorted by chance errors only

  4. Coulometric titration of niobium in 1F sulfuric acid

    International Nuclear Information System (INIS)

    Pannu, S.S.

    1975-01-01

    A coulometric titration at constant current has been devised for Nb in 1F sulfuric acid. The titration was based on the oxidation of Nb(III) to Nb(V) by Fe(III) electrogenerated at a graphite anode. Both potentiometric and amperometric end points were used. The Nb(V) was prior reduced at a mercury cathode by exhaustive electrolysis at a current density of 15 ma/mc 2 for at least 10 hr. Ta,V,Ti and a working platinum anode interfered, but the separation of the potentials of Nb(V)/Nb(III) and Ti(IV)/Ti(III) permitted the titration of first Nb and then Ti. The average error for the titration of 0.30 to 13.00 mg of niobium in 100 ml of 1F sulfuric acid was + 0.57%. (author)

  5. Green chemistry volumetric titration kit for pharmaceutical formulations: Econoburette

    Directory of Open Access Journals (Sweden)

    Man Singh

    2009-08-01

    Full Text Available Stopcock SC and Spring Sp models of Econoburette (Calibrated, RTC (NR, Ministry of Small Scale Industries, Government of India, developed for semimicro volumetric titration of pharmaceutical formulations are reported. These are economized and risk free titration where pipette is replaced by an inbuilt pipette and conical flask by inbuilt bulb. A step of pipetting of stock solution by mouth is deleted. It is used to allow solution exposure to user’s body. This risk is removed and even volatile and toxic solutions are titrated with full proof safety. Econoburette minimizes use of materials and time by 90 % and prevent discharge of polluting effluent to environment. Few acid and base samples are titrated and an analysis of experimental expenditure is described in the papers.

  6. Potentiometric titration of free acid in uranium solutions

    International Nuclear Information System (INIS)

    Suh, M. Y.; Kim, W. H.; Kim, J. S.; Sohn, S. C.; Eom, T. Y.; Lee, C. H.; Jeon, Y. S.; Han, S. H.

    1998-02-01

    Hydrolysis properties of metal cations and fundamental principles of the potentiometric titration of free acid in aqueous solutions containing metal cations were described. The published papers and reports for the alkalimetric and acidimetric titration of free acid were surveyed, and the applicability of these titration methods to the uranium and/or plutonium solutions were discussed. This technical report also includes the various results obtained from the authors' researches to establish the alkalimetric and acidimetric titration methods for the determination of free acid in nitric acid solutions containing uranium and/or oxalic acid, and aluminum. The procedure manuals used in chemical processes and the newly prepared manuals based on the authors' researches are appended. (author). 26 refs., 54 figs

  7. Potentiometric titration of free acid in uranium solutions

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Kim, W. H.; Kim, J. S.; Sohn, S. C.; Eom, T. Y.; Lee, C. H.; Jeon, Y. S.; Han, S. H.

    1998-02-01

    Hydrolysis properties of metal cations and fundamental principles of the potentiometric titration of free acid in aqueous solutions containing metal cations were described. The published papers and reports for the alkalimetric and acidimetric titration of free acid were surveyed, and the applicability of these titration methods to the uranium and/or plutonium solutions were discussed. This technical report also includes the various results obtained from the authors` researches to establish the alkalimetric and acidimetric titration methods for the determination of free acid in nitric acid solutions containing uranium and/or oxalic acid, and aluminum. The procedure manuals used in chemical processes and the newly prepared manuals based on the authors` researches are appended. (author). 26 refs., 54 figs.

  8. A Titration Technique for Demonstrating a Magma Replenishment Model.

    Science.gov (United States)

    Hodder, A. P. W.

    1983-01-01

    Conductiometric titrations can be used to simulate subduction-setting volcanism. Suggestions are made as to the use of this technique in teaching volcanic mechanisms and geochemical indications of tectonic settings. (JN)

  9. A microcomputer-controlled system for titration analysis

    NARCIS (Netherlands)

    Boelema, Gerrit Jan

    1982-01-01

    This thesis deals with the results of the implementation of microprocessor technology in automatic titration equipment to obtain a versatile system for pharmaceutical, chemical analytical and optimization research purposes. ... Zie: Summary

  10. A reliable and feasible qPCR strategy for titrating AAV vectors.

    Science.gov (United States)

    Wang, Feng; Cui, Xiuling; Wang, Mingxi; Xiao, Weidong; Xu, Ruian

    2013-07-05

    Previous studies have revealed that traditional real-time quantitative PCR (qPCR) underestimates adeno-associated virus (AAV) titer. Because the inverted terminal repeat (ITR) exists in all AAV vectors, the only remaining element from the wild genome could form special configurations to interfere with qPCR titration. To solve this problem, a modified and universal qPCR method was tested and established. In this work, there was a great variation in titration of ssAAV2-EGFP (Enhanced Green Fluorescence Protein) and scAAV2-EGFP genome by traditional qPCR. For ssAAV2-EGFP, the highest titer was found by using the targeting EGFP primers and the lowest titer was measured by those targeting bovine growth hormone polyA element (pBGH) primers. Experimental data were reverse for ssAAV2-EGFP and scAAV2-EGFP. Here we report an improved and universal SmaI qPCR method, based on cleaving all ITRs in AAV2 genome by SmaI with several advantages: (1) impact of all ITRs in ssAAV2 and scAAV2 was dismissed; (2) titers increased remarkably, up to 7-fold, especially for scAAV2; (3) the variation of titers was reduced when different primers were applied. A similar phenomenon was also observed in other ssAAV2 and scAAV2 products when the range of titration was at 3×107 to 7×109 V.G/µl in this study. This modified qPCR strategy can increase rAAV' titer and reduce titration variance, possibly become a universal method for titrating AAV vectors.

  11. A fully automatic system for acid-base coulometric titrations

    OpenAIRE

    Cladera, A.; Caro, A.; Estela, J. M.; Cerdà, V.

    1990-01-01

    An automatic system for acid-base titrations by electrogeneration of H+ and OH- ions, with potentiometric end-point detection, was developed. The system includes a PC-compatible computer for instrumental control, data acquisition and processing, which allows up to 13 samples to be analysed sequentially with no human intervention. The system performance was tested on the titration of standard solutions, which it carried out with low errors and RSD. It was subsequently applied to the analysis o...

  12. Amperometric titration of indium with edta solution in propanol

    International Nuclear Information System (INIS)

    Gevorgyan, A.M.; Talipov, Sh.T.; Khadeev, V.A.; Kostylev, V.S.; Khadeeva, L.A.

    1980-01-01

    Optimum conditions have been chosen for titration of indium with EDTA solution in anhydrous propanol and its mixtures with some aprotic solvents using amperometric and point detection. A procedure is suggested of determining indium microcontents in the presence of large amounts of other elements. The procedure is based on its extraction preseparation followed by direct titration in the extract with a standard EDTA solution [ru

  13. Thermometric titrations of amines with nitrosyl perchlorate in acetonitrile solvent.

    Science.gov (United States)

    Gündüz, T; Kiliç, E; Cakirer, O

    1996-05-01

    Thirteen aliphatic and four aromatic amines, namely diethylamine, triethylamine, n-propylamine, di-n-propylamine, tri-n-butylamine, isopropylamine, di-isopropylamine, n-butylamine, di-n-butylamine, tri-n-butylamine, isobutylamine, sec-butylamine, tert-butylamine, aniline, N,N-dimethylaniline, 2-nitroaniline and 4-nitroaniline were titrated thermometrically with nitrosyl perchlorate in acetonitrile solvent. All the aliphatic amines gave very well-shaped thermometric titration curves. The calculated recovery values of the amines were very good. In comparison, the aromatic amines, aniline and N,N-dimethylaniline gave rather well-shaped titration curves, but the recovery values were fairly low. 2-Nitro- and 4-nitro anilines gave no thermometric response at all. The heats of reaction of the amines with nitrosyl perchlorate are rather high. However, the average heat of reaction of the aromatic amines is approximately two-thirds that of the average heat of the aliphatic amines. To support this method all the amines were also titrated potentiometrically and very similar results to those obtained with the thermometric method are seen. The nitrosyl ion is a Lewis acid, strong enough to titrate quantitatively aliphatic amines in acetonitrile solvent, but not strong enough to titrate aromatic amines at the required level in the same solvent.

  14. Gran method for end point anticipation in monosegmented flow titration

    Directory of Open Access Journals (Sweden)

    Aquino Emerson V

    2004-01-01

    Full Text Available An automatic potentiometric monosegmented flow titration procedure based on Gran linearisation approach has been developed. The controlling program can estimate the end point of the titration after the addition of three or four aliquots of titrant. Alternatively, the end point can be determined by the second derivative procedure. In this case, additional volumes of titrant are added until the vicinity of the end point and three points before and after the stoichiometric point are used for end point calculation. The performance of the system was assessed by the determination of chloride in isotonic beverages and parenteral solutions. The system employs a tubular Ag2S/AgCl indicator electrode. A typical titration, performed according to the IUPAC definition, requires only 60 mL of sample and about the same volume of titrant (AgNO3 solution. A complete titration can be carried out in 1 - 5 min. The accuracy and precision (relative standard deviation of ten replicates are 2% and 1% for the Gran and 1% and 0.5% for the Gran/derivative end point determination procedures, respectively. The proposed system reduces the time to perform a titration, ensuring low sample and reagent consumption, and full automatic sampling and titrant addition in a calibration-free titration protocol.

  15. Numerical study of divertor plasma transport with thermal force due to temperature gradient

    International Nuclear Information System (INIS)

    Ohtsu, Shigeki; Tanaka, Satoru; Yamawaki, Michio

    1992-01-01

    A one-dimensional, steady state divertor plasma model is developed in order to study the carbon impurity transport phenomena considering thermal force. The divertor plasma is composed of four regions in terms of momentum transport between hydrogen and carbon impurity: Momentum transferring region, equilibrium region, hydrogen recycling region and carbon recycling region. In the equilibrium region where the friction force is counterbalanced by the thermal force, the localization of carbon impurity occurs. The sufficient condition to avoid the reverse of carbon velocity due to the thermal force is evaluated. (orig.)

  16. A single-beam titration method for the quantification of open-path Fourier transform infrared spectroscopy

    International Nuclear Information System (INIS)

    Sung, Lung-Yu; Lu, Chia-Jung

    2014-01-01

    This study introduced a quantitative method that can be used to measure the concentration of analytes directly from a single-beam spectrum of open-path Fourier Transform Infrared Spectroscopy (OP-FTIR). The peak shapes of the analytes in a single-beam spectrum were gradually canceled (i.e., “titrated”) by dividing an aliquot of a standard transmittance spectrum with a known concentration, and the sum of the squared differential synthetic spectrum was calculated as an indicator for the end point of this titration. The quantity of a standard transmittance spectrum that is needed to reach the end point can be used to calculate the concentrations of the analytes. A NIST traceable gas standard containing six known compounds was used to compare the quantitative accuracy of both this titration method and that of a classic least square (CLS) using a closed-cell FTIR spectrum. The continuous FTIR analysis of industrial exhausting stack showed that concentration trends were consistent between the CLS and titration methods. The titration method allowed the quantification to be performed without the need of a clean single-beam background spectrum, which was beneficial for the field measurement of OP-FTIR. Persistent constituents of the atmosphere, such as NH 3 , CH 4 and CO, were successfully quantified using the single-beam titration method with OP-FTIR data that is normally inaccurate when using the CLS method due to the lack of a suitable background spectrum. Also, the synthetic spectrum at the titration end point contained virtually no peaks of analytes, but it did contain the remaining information needed to provide an alternative means of obtaining an ideal single-beam background for OP-FTIR. - Highlights: • Establish single beam titration quantification method for OP-FTIR. • Define the indicator for the end-point of spectrum titration. • An ideal background spectrum can be obtained using single beam titration. • Compare the quantification between titration

  17. Thermodynamic signatures of fragment binding: Validation of direct versus displacement ITC titrations.

    Science.gov (United States)

    Rühmann, Eggert; Betz, Michael; Fricke, Marie; Heine, Andreas; Schäfer, Martina; Klebe, Gerhard

    2015-04-01

    Detailed characterization of the thermodynamic signature of weak binding fragments to proteins is essential to support the decision making process which fragments to take further for the hit-to-lead optimization. Isothermal titration calorimetry (ITC) is the method of choice to record thermodynamic data, however, weak binding ligands such as fragments require the development of meaningful and reliable measuring protocols as usually sigmoidal titration curves are hardly possible to record due to limited solubility. Fragments can be titrated either directly under low c-value conditions (no sigmoidal curve) or indirectly by use of a strong binding ligand displacing the pre-incubated weak fragment from the protein. The determination of Gibbs free energy is reliable and rather independent of the applied titration protocol. Even though the displacement method achieves higher accuracy, the obtained enthalpy-entropy profile depends on the properties of the used displacement ligand. The relative enthalpy differences across different displacement experiments reveal a constant signature and can serve as a thermodynamic fingerprint for fragments. Low c-value titrations are only reliable if the final concentration of the fragment in the sample cell exceeds 2-10 fold its K(D) value. Limited solubility often prevents this strategy. The present study suggests an applicable protocol to characterize the thermodynamic signature of protein-fragment binding. It shows however, that such measurements are limited by protein and fragment solubility. Deviating profiles obtained by use of different displacement ligands indicate that changes in the solvation pattern and protein dynamics most likely take influence on the resulting overall binding signature. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Feasibility and Association of Neurohumoral Blocker Up-titration After Cardiac Resynchronization Therapy.

    Science.gov (United States)

    Martens, Pieter; Verbrugge, Frederik H; Nijst, Petra; Bertrand, Philippe B; Dupont, Matthias; Tang, Wilson H; Mullens, Wilfried

    2017-08-01

    Cardiac resynchronization therapy (CRT) improves mortality and morbidity on top of optimal medical therapy in heart failure with reduced ejection fraction (HFrEF). This study aimed to elucidate the association between neurohumoral blocker up-titration after CRT implantation and clinical outcomes. Doses of angiotensin-converting enzyme inhibitors (ACE-Is), angiotensin receptor blockers (ARBs), and beta-blockers were retrospectively evaluated in 650 consecutive CRT patients implanted from October 2008 to August 2015 and followed in a tertiary multidisciplinary CRT clinic. All 650 CRT patients were on a maximal tolerable dose of ACE-I/ARB and beta-blocker at the time of CRT implantation. However, further up-titration was successful in 45.4% for ACE-I/ARB and in 56.8% for beta-blocker after CRT-implantation. During a mean follow-up of 37 ± 22 months, a total of 139 events occurred for the combined end point of heart failure admission and all-cause mortality. Successful, versus unsuccessful, up-titration was associated with adjusted hazard ratios of 0.537 (95% confidence interval 0.316-0.913; P = .022) for ACE-I/ARB and 0.633 (0.406-0.988; P = .044) for beta-blocker on the combined end point heart failure admission and all-cause mortality. Patients in the up-titration group exhibited a similar risk for death or heart failure admission as patients treated with the maximal dose (ACE-I/ARB: P = .133; beta-blockers: P = .709). After CRT, a majority of patients are capable of tolerating higher dosages of neurohumoral blockers. Up-titration of neurohumoral blockers after CRT implantation is associated with improved clinical outcomes, similarly to patients treated with the guideline-recommended target dose at the time of CRT implantation. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Atomic force microscopy studies of native photosynthetic membranes.

    Science.gov (United States)

    Sturgis, James N; Tucker, Jaimey D; Olsen, John D; Hunter, C Neil; Niederman, Robert A

    2009-05-05

    In addition to providing the earliest surface images of a native photosynthetic membrane at submolecular resolution, examination of the intracytoplasmic membrane (ICM) of purple bacteria by atomic force microscopy (AFM) has revealed a wide diversity of species-dependent arrangements of closely packed light-harvesting (LH) antennae, capable of fulfilling the basic requirements for efficient collection, transmission, and trapping of radiant energy. A highly organized architecture was observed with fused preparations of the pseudocrystalline ICM of Blastochloris viridis, consiting of hexagonally packed monomeric reaction center light-harvesting 1 (RC-LH1) core complexes. Among strains which also form a peripheral LH2 antenna, images of ICM patches from Rhodobacter sphaeroides exhibited well-ordered, interconnected networks of dimeric RC-LH1 core complexes intercalated by rows of LH2, coexisting with LH2-only domains. Other peripheral antenna-containing species, notably Rhodospirillum photometricum and Rhodopseudomonas palustris, showed a less regular organization, with mixed regions of LH2 and RC-LH1 cores, intermingled with large, paracrystalline domains. The ATP synthase and cytochrome bc(1) complex were not observed in any of these topographs and are thought to be localized in the adjacent cytoplasmic membrane or in inaccessible ICM regions separated from the flat regions imaged by AFM. The AFM images have served as a basis for atomic-resolution modeling of the ICM vesicle surface, as well as forces driving segregation of photosynthetic complexes into distinct domains. Docking of atomic-resolution molecular structures into AFM topographs of Rsp. photometricum membranes generated precise in situ structural models of the core complex surrounded by LH2 rings and a region of tightly packed LH2 complexes. A similar approach has generated a model of the highly curved LH2-only membranes of Rba. sphaeroides which predicts that sufficient space exists between LH2 complexes

  20. A theoretical study on the influence of gas adsorption on interparticle forces in powders

    NARCIS (Netherlands)

    Cottaar, E.J.E.; Rietema, K.

    1986-01-01

    Using data from the literature and some additional experiments it is investigated whether the interparticle forces in general and more specifically the cohesion between particles are influenced by the physisorption of gases. In this otherwise theoretical study the force to be applied to a particle

  1. A study of forced convective subcooled flow boiling

    International Nuclear Information System (INIS)

    Serizawa, Akimi; Kenning, D.B.R.

    1979-01-01

    Based on a simple nucleation model, parameter survey technique is used to derive a predictive correlation for boiling initiation under forced convection. Results are expressed by a semi-empirical equation which considers effects of the flow turbulence on interfacial heat transfer coefficient for evaporation and condensation of vapour bubbles during their growth. This correlation agrees within +-25% with a variety of experimental water data presently available. The bubble departure diameter and the subcooling-dependence of active nucleation sites were examined, using experimental data available. Results are expressed by empirical equations. Finally, an analytical model is presented to predict conditions for the point of net vapour generation. The model is based on the formation and growth of a bubble boundary layer adjacent to the heated wall. It is shown that the point of net vapour generation is determined by the liquid subcooling at the boiling initiation and the subcooling-dependences of bubble departure diameter and bubble flux. The result implies that the bubble ejection from bubble layer is a possible mechanism for the significant void increase even at high velocities. (author)

  2. Measuring titratable alkalinity by single versus double endpoint titration: An evaluation in two cyprinodont species and implications for characterizing net H+ flux in aquatic organisms.

    Science.gov (United States)

    Brix, Kevin V; Wood, Chris M; Grosell, Martin

    2013-01-01

    In this study, Na(+) uptake and acid-base balance in the euryhaline pupfish Cyprinodon variegatus variegatus were characterized when fish were exposed to pH 4.5 freshwater (7mM Na(+)). Similar to the related cyprinodont, Fundulus heteroclitus, Na(+) uptake was significantly inhibited when exposed to low pH water. However, it initially appeared that C. v. variegatus increased apparent net acid excretion at low pH relative to circumneutral pH. This result is opposite to previous observations for F. heteroclitus under similar conditions where fish were observed to switch from apparent net H(+) excretion at circumneutral pH to apparent net H(+) uptake at low pH. Further investigation revealed disparate observations between these studies were the result of using double endpoint titrations to measure titratable alkalinity fluxes in the current study, while the earlier study utilized single endpoint titrations to measure these fluxes (i.e.,. Cyprinodon acid-base transport is qualitatively similar to Fundulus when characterized using single endpoint titrations). This led to a comparative investigation of these two methods. We hypothesized that either the single endpoint methodology was being influenced by a change in the buffer capacity of the water (e.g., mucus being released by the fish) at low pH, or the double endpoint methodology was not properly accounting for ammonia flux by the fish. A series of follow-up experiments indicated that buffer capacity of the water did not change significantly, that excretion of protein (a surrogate for mucus) was actually reduced at low pH, and that the double endpoint methodology does not properly account for NH(3) excretion by fish under low pH conditions. As a result, it overestimates net H(+) excretion during low pH exposure. After applying the maximum possible correction for this error (i.e., assuming that all ammonia is excreted as NH(3)), the double endpoint methodology indicates that net H(+) transport was reduced to

  3. Small-angle X-ray titration study on the complex formation between 5-S RNA and the L18 protein of the Escherichia coli 50-S ribosome particle

    International Nuclear Information System (INIS)

    Oesterberg, R.; Garrett, A.

    1977-01-01

    The 5-S RNA (A) and the L 18 protein (B) from Escherichia coli ribosomes form one single AB complex in the concentration ranges supposed to prevail in vivo; at concentrations of L 18 higher than 40 mM there is some indication for a minor species, most probably an AB 2 species. This is indicated from the X-ray scattering titration data of the 5-S RNA/L 18 system recorded at 21 0 C in ribosomal reconstitution buffer. As a result of the 1 : 1 complex formation, there is a relatively small but defined increase in the radius of gyration from 3.61 to 3.85 nm. This result as well as the experimental scattering curve can be explained by models where it is assumed that the elongated L 18 model is quite far from the electron density centre and where protein L 18 interacts with one or both of the minor arms of the supposed Y-shaped 5-S RNA molecule. (orig.) [de

  4. Rapid clozapine titration in treatment-refractory bipolar disorder.

    Science.gov (United States)

    Ifteni, Petru; Correll, Christoph U; Nielsen, Jimmi; Burtea, Victoria; Kane, John M; Manu, Peter

    2014-09-01

    Clozapine is effective in treatment-refractory bipolar disorder (BD). Guidelines recommend slow titration to prevent seizures, hypotension and myocarditis, but this stance is not supported by comparative data. To evaluate the safety and effectiveness of rapid clozapine titration in BD. Analysis of a consecutive cohort of treatment-refractory BD patients with mixed/manic episode admitted on alternate days to one of two units of a psychiatric hospital. On one unit, clozapine was started at 25mg followed by 25-50mg as needed every 6h (maximum=100mg/day) on day 1, followed by increases of 25-100mg/day. On the other unit, clozapine was initiated with 25mg in day 1, followed by increases of 25-50mg/day. The primary outcome was the number of days from starting clozapine until readiness for discharge, adjusted in logistic regression for the number of antipsychotics tried during the hospitalization, psychotropic co-treatments and presence of psychotic features. Patients subject to rapid (N=44) and standard (N=23) titration were similar in age, gender, smoking status, body mass index, illness severity at baseline and discharge, and highest clozapine dose. Clozapine was discontinued due to hypotension (N=1) and pneumonia (N=1) during rapid titration, and for excessive sedation (N=1) in each titration group. The number of hospital days from starting clozapine until readiness for discharge was 3.8 days shorter in the rapid titration group (12.7±6.3 vs. 16.5±5.8, p=0.0077). Rapid clozapine titration appeared safe and effective for treatment-refractory BD. The potential for shorter hospital stays justifies prospective trials of this method. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Impact of Uniform Methods on Interlaboratory Antibody Titration Variability: Antibody Titration and Uniform Methods.

    Science.gov (United States)

    Bachegowda, Lohith S; Cheng, Yan H; Long, Thomas; Shaz, Beth H

    2017-01-01

    -Substantial variability between different antibody titration methods prompted development and introduction of uniform methods in 2008. -To determine whether uniform methods consistently decrease interlaboratory variation in proficiency testing. -Proficiency testing data for antibody titration between 2009 and 2013 were obtained from the College of American Pathologists. Each laboratory was supplied plasma and red cells to determine anti-A and anti-D antibody titers by their standard method: gel or tube by uniform or other methods at different testing phases (immediate spin and/or room temperature [anti-A], and/or anti-human globulin [AHG: anti-A and anti-D]) with different additives. Interlaboratory variations were compared by analyzing the distribution of titer results by method and phase. -A median of 574 and 1100 responses were reported for anti-A and anti-D antibody titers, respectively, during a 5-year period. The 3 most frequent (median) methods performed for anti-A antibody were uniform tube room temperature (147.5; range, 119-159), uniform tube AHG (143.5; range, 134-150), and other tube AHG (97; range, 82-116); for anti-D antibody, the methods were other tube (451; range, 431-465), uniform tube (404; range, 382-462), and uniform gel (137; range, 121-153). Of the larger reported methods, uniform gel AHG phase for anti-A and anti-D antibodies had the most participants with the same result (mode). For anti-A antibody, 0 of 8 (uniform versus other tube room temperature) and 1 of 8 (uniform versus other tube AHG), and for anti-D antibody, 0 of 8 (uniform versus other tube) and 0 of 8 (uniform versus other gel) proficiency tests showed significant titer variability reduction. -Uniform methods harmonize laboratory techniques but rarely reduce interlaboratory titer variance in comparison with other methods.

  6. Study on Characteristics of Hydraulic Servo System for Force Control of Hydraulic Robots

    International Nuclear Information System (INIS)

    Kim, Hyo-gon; Han, Changsoo; Lee, Jong-won; Park, Sangdeok

    2015-01-01

    Because a hydraulic actuator has high power and force densities, this allows the weight of the robot's limbs to be reduced. This allows for good dynamic characteristics and high energy efficiency. Thus, hydraulic actuators are used in some exoskeleton robots and quadrupedal robots that require high torque. Force control is useful for robot compliance with a user or environment. However, force control of a hydraulic robot is difficult because a hydraulic servo system is highly nonlinear from a control perspective. In this study, a nonlinear model was used to develop a simulation program for a hydraulic servo system consisting of a servo valve, transmission lines, and a cylinder. The problems and considerations with regard to the force control performance for a hydraulic servo system were investigated. A force control method using the nonlinear model was proposed, and its effect was evaluated with the simulation program

  7. Study on Characteristics of Hydraulic Servo System for Force Control of Hydraulic Robots

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyo-gon; Han, Changsoo [Hanyang University, Seoul (Korea, Republic of); Lee, Jong-won [Korea University of Science and Technology, Seoul (Korea, Republic of); Park, Sangdeok [Korea Institute of Industrial Technology, Seoul (Korea, Republic of)

    2015-02-15

    Because a hydraulic actuator has high power and force densities, this allows the weight of the robot's limbs to be reduced. This allows for good dynamic characteristics and high energy efficiency. Thus, hydraulic actuators are used in some exoskeleton robots and quadrupedal robots that require high torque. Force control is useful for robot compliance with a user or environment. However, force control of a hydraulic robot is difficult because a hydraulic servo system is highly nonlinear from a control perspective. In this study, a nonlinear model was used to develop a simulation program for a hydraulic servo system consisting of a servo valve, transmission lines, and a cylinder. The problems and considerations with regard to the force control performance for a hydraulic servo system were investigated. A force control method using the nonlinear model was proposed, and its effect was evaluated with the simulation program.

  8. The Impacts of Daily Surface Forcing in the Upper Ocean over Tropical Pacific: A Numerical Study

    Science.gov (United States)

    Sui, C.-H.; Rienecker, Michele M.; Li, Xiaofan; Lau, William K.-M.; Laszlo, Istvan; Pinker, Rachel T.

    2001-01-01

    Tropical Pacific Ocean is an important region that affects global climate. How the ocean responds to the atmospheric surface forcing (surface radiative, heat and momentum fluxes) is a major topic in oceanographic research community. The ocean becomes warm when more heat flux puts into the ocean. The monthly mean forcing has been used in the past years since daily forcing was unavailable due to the lack of observations. The daily forcing is now available from the satellite measurements. This study investigates the response of the upper ocean over tropical Pacific to the daily atmospheric surface forcing. The ocean surface heat budgets are calculated to determine the important processes for the oceanic response. The differences of oceanic responses between the eastern and western Pacific are intensively discussed.

  9. Knot probability of polygons subjected to a force: a Monte Carlo study

    International Nuclear Information System (INIS)

    Rensburg, E J Janse van; Orlandini, E; Tesi, M C; Whittington, S G

    2008-01-01

    We use Monte Carlo methods to study the knot probability of lattice polygons on the cubic lattice in the presence of an external force f. The force is coupled to the span of the polygons along a lattice direction, say the z-direction. If the force is negative polygons are squeezed (the compressive regime), while positive forces tend to stretch the polygons along the z-direction (the tensile regime). For sufficiently large positive forces we verify that the Pincus scaling law in the force-extension curve holds. At a fixed number of edges n the knot probability is a decreasing function of the force. For a fixed force the knot probability approaches unity as 1 - exp(-α 0 (f)n + o(n)), where α 0 (f) is positive and a decreasing function of f. We also examine the average of the absolute value of the writhe and we verify the square root growth law (known for f = 0) for all values of f

  10. Comparison of manual versus automatic continuous positive airway pressure titration and the development of a predictive equation for therapeutic continuous positive airway pressure in Chinese patients with obstructive sleep apnoea.

    Science.gov (United States)

    Luo, Jiaying; Xiao, Sichang; Qiu, Zhihui; Song, Ning; Luo, Yuanming

    2013-04-01

    Whether the therapeutic nasal continuous positive airway pressure (CPAP) derived from manual titration is the same as derived from automatic titration is controversial. The purpose of this study was to compare the therapeutic pressure derived from manual titration with automatic titration. Fifty-one patients with obstructive sleep apnoea (OSA) (mean apnoea/hypopnoea index (AHI) = 50.6 ± 18.6 events/h) who were newly diagnosed after an overnight full polysomnography and who were willing to accept CPAP as a long-term treatment were recruited for the study. Manual titration during full polysomnography monitoring and unattended automatic titration with an automatic CPAP device (REMstar Auto) were performed. A separate cohort study of one hundred patients with OSA (AHI = 54.3 ± 18.9 events/h) was also performed by observing the efficacy of CPAP derived from manual titration. The treatment pressure derived from automatic titration (9.8 ± 2.2 cmH(2)O) was significantly higher than that derived from manual titration (7.3 ± 1.5 cmH(2)O; P titration (54.3 ± 18.9 events/h before treatment and 3.3 ± 1.7 events/h after treatment; P titration pressure derived from REMstar Auto is usually higher than the pressure derived from manual titration. © 2013 The Authors. Respirology © 2013 Asian Pacific Society of Respirology.

  11. An RCT Investigating Patient-Driven Versus Physician-Driven Titration of BIAsp 30 in Patients with Type 2 Diabetes Uncontrolled Using NPH Insulin.

    Science.gov (United States)

    Chraibi, Abdelmjid; Al-Herz, Shoorook; Nguyen, Bich Dao; Soeatmadji, Djoko W; Shinde, Anil; Lakshmivenkataraman, Balasubramanian; Assaad-Khalil, Samir H

    2017-08-01

    The aim of this study was to confirm the efficacy of patient-driven titration of BIAsp 30 in terms of glycemic control, by comparing it to physician-driven titration of BIAsp 30, in patients with type 2 diabetes in North Africa, the Middle East, and Asia. A 20-week, open-label, randomized, two-armed, parallel-group, multicenter study in Egypt, Indonesia, Morocco, Saudi Arabia, and Vietnam. Patients (n = 155) with type 2 diabetes inadequately controlled using neutral protamine Hagedorn (NPH) insulin were randomized to either patient-driven or physician-driven BIAsp 30 titration. The noninferiority of patient-driven compared to physician-driven titration with respect to the reduction in HbA1c was confirmed. The estimated mean change in HbA1c from baseline to week 20 was -1.27% in the patient-driven arm and -1.04% in the physician-driven arm, with an estimated treatment difference of -0.23% (95% confidence interval: -0.54; 0.08). After 20 weeks of treatment, the proportions of patients achieving the target of HbA1c titration arms; the proportions of patients achieving the target of ≤6.5% were also similar. Both titration algorithms were well tolerated, and hypoglycemic episode rates were similar in both arms. Patient-driven titration of BIAsp 30 can be as effective and safe as physician-driven titration in non-Western populations. Overall, the switch from NPH insulin to BIAsp 30 was well tolerated in both titration arms and led to improved glycemic control. A limitation of the study was the relatively small number of patients recruited in each country. ClinicalTrials.gov NCT01589653. Novo Nordisk A/S, Denmark.

  12. Potentiometric titration and equivalent weight of humic acid

    Science.gov (United States)

    Pommer, A.M.; Breger, I.A.

    1960-01-01

    The "acid nature" of humic acid has been controversial for many years. Some investigators claim that humic acid is a true weak acid, while others feel that its behaviour during potentiometric titration can be accounted for by colloidal adsorption of hydrogen ions. The acid character of humic acid has been reinvestigated using newly-derived relationships for the titration of weak acids with strong base. Re-interpreting the potentiometric titration data published by Thiele and Kettner in 1953, it was found that Merck humic acid behaves as a weak polyelectrolytic acid having an equivalent weight of 150, a pKa of 6.8 to 7.0, and a titration exponent of about 4.8. Interdretation of similar data pertaining to the titration of phenol-formaldehyde and pyrogallol-formaldehyde resins, considered to be analogs for humic acid by Thiele and Kettner, leads to the conclusion that it is not possible to differentiate between adsorption and acid-base reaction for these substances. ?? 1960.

  13. Study of Radiative Forcing of Dust Aerosols and its impact on Climate Characteristics

    KAUST Repository

    Qureshi, Fawwad H

    2012-01-01

    The purpose of following project is to study the effect of dust aerosols on the radiative forcing which is directly related to the surface temperature. A single column radiative convective model is used for simulation purpose. A series

  14. Control of OSA during automatic positive airway pressure titration in a clinical case series: predictors and accuracy of device download data.

    Science.gov (United States)

    Huang, Hsin-Chia Carol; Hillman, David R; McArdle, Nigel

    2012-09-01

    To investigate the factors associated with physiologic control of obstructive sleep apnea (OSA) during automatic positive airway pressure (APAP) titration in a clinical series. To also assess the usefulness of apnea-hypopnea index (AHI) data downloaded from the APAP device (Dev AHI). Retrospective review of a consecutive series of patients with OSA who underwent APAP titration (Autoset Spirit, ResMed, Bella Vista, New South Wales, Australia ) with simultaneous polysomnographic (PSG) monitoring in the sleep laboratory. Tertiary sleep clinic. There were 190 consecutive patients with OSA referred for APAP titration. There were 58% of patients who achieved optimal or good control of OSA (titration PSG AHI titration. The independent predictors of titration PSG AHI were a history of cardiac disease and elevated central apnea and arousal indices during the diagnostic study. Although the median and interquartile range (IQR) AHI from the device (7.0, 3.9-11.6 events/hr) was only slightly less than the PSG AHI (7.8, 3.9-14.4 events/hr, P = 0.04) during titration, case-by-case agreement between the two measures was poor (chi-square titration is often poor, and close clinical follow-up is particularly needed in patients with a history of cardiac disease or with high arousal or central apnea indices on the diagnostic study. Device AHI does not reliably assess control during APAP titration, and PSG assessment may be required if clinical response to treatment is poor. The findings relate to the ResMed AutoSet device and may not apply to other devices.

  15. Optimizing Glycemic Control Through Titration of Insulin Glargine 100 U/mL: A Review of Current and Future Approaches with a Focus on Asian Populations.

    Science.gov (United States)

    Deerochanawong, Chaicharn; Bajpai, Shailendra; Dwipayana, I Made Pande; Hussein, Zanariah; Mabunay, Maria Aileen; Rosales, Reynaldo; Tsai, Shih-Tzer; Tsang, Man Wo

    2017-12-01

    Various data have demonstrated inadequate glycemic control amongst Asians with type 2 diabetes mellitus (T2DM), possibly on account of suboptimal titration of basal insulin-an issue which needs to be further examined. Here we review the available global and Asia-specific data on titration of basal insulin, with a focus on the use of insulin glargine 100 U/mL (Gla-100). We also discuss clinical evidence on the efficacy and safety of titrating Gla-100, different approaches to titration, including some of the latest technological advancements, and guidance on the titration of basal insulin from international and local Asian guidelines. The authors also provide their recommendations for the initiation and titration of basal insulin for Asian populations. Discussion of the data included in this review and in relation to the authors' clinical experience with treating T2DM in Asian patients is also included. Briefly, clinical studies demonstrate the achievement of adequate glycemic control in adults with T2DM through titration of Gla-100. However, studies investigating approaches to titration, specifically in Asian populations, are lacking and need to be conducted. Given that the management of insulin therapy is a multidisciplinary team effort involving endocrinologists, primary care physicians, nurse educators, and patients, greater resources and education targeted at these groups are needed regarding the optimal titration of basal insulin. Technological advancements in the form of mobile or web-based applications for automated dose adjustment can aid different stakeholders in optimizing the dose of basal insulin, enabling a larger number of patients in Asia to reach their target glycemic goals with improved outcomes.

  16. Spasmodic dysphonia: a seven-year audit of dose titration and demographics in the Indian population.

    Science.gov (United States)

    Nerurkar, N K; Banu, T P

    2014-07-01

    This study aimed to evaluate the demographics of spasmodic dysphonia in the Indian population and to analyse the optimum dose titration of botulinum toxin type A in this group. A comparative analysis with international studies was also performed. The study involved a retrospective analysis and audit of botulinum toxin type A dose titration in spasmodic dysphonia patients who visited our voice clinic between January 2005 and January 2012. The average total therapeutic dose required for patients with adductor spasmodic dysphonia was 4.2 U per patient per vocal fold (total 8.4 U per patient), and for patients with abductor spasmodic dysphonia, it was 4.6 U per patient. Our audit revealed that 80 per cent of the spasmodic dysphonia patients were male, which contrasts dramatically with international studies, wherein around 80 per cent of spasmodic dysphonia patients were female. Our study also revealed a higher dose titration of botulinum toxin for the Indian spasmodic dysphonia population in both adductor and abductor spasmodic dysphonia cases.

  17. A Geochemical Reaction Model for Titration of Contaminated Soil and Groundwater at the Oak Ridge Reservation

    Science.gov (United States)

    Zhang, F.; Parker, J. C.; Gu, B.; Luo, W.; Brooks, S. C.; Spalding, B. P.; Jardine, P. M.; Watson, D. B.

    2007-12-01

    This study investigates geochemical reactions during titration of contaminated soil and groundwater at the Oak Ridge Reservation in eastern Tennessee. The soils and groundwater exhibits low pH and high concentrations of aluminum, calcium, magnesium, manganese, various trace metals such as nickel and cobalt, and radionuclides such as uranium and technetium. The mobility of many of the contaminant species diminishes with increasing pH. However, base additions to increase pH are strongly buffered by various precipitation/dissolution and adsorption/desorption reactions. The ability to predict acid-base behavior and associated geochemical effects is thus critical to evaluate remediation performance of pH manipulation strategies. This study was undertaken to develop a practical but generally applicable geochemical model to predict aqueous and solid-phase speciation during soil and groundwater titration. To model titration in the presence of aquifer solids, an approach proposed by Spalding and Spalding (2001) was utilized, which treats aquifer solids as a polyprotic acid. Previous studies have shown that Fe and Al-oxyhydroxides strongly sorb dissolved Ni, U and Tc species. In this study, since the total Fe concentration is much smaller than that of Al, only ion exchange reactions associated with Al hydroxides are considered. An equilibrium reaction model that includes aqueous complexation, precipitation, ion exchange, and soil buffering reactions was developed and implemented in the code HydroGeoChem 5.0 (HGC5). Comparison of model results with experimental titration curves for contaminated groundwater alone and for soil- water systems indicated close agreement. This study is expected to facilitate field-scale modeling of geochemical processes under conditions with highly variable pH to develop practical methods to control contaminant mobility at geochemically complex sites.

  18. Determination of uranium by direct titration with dipicolinic acid

    International Nuclear Information System (INIS)

    Baumann, E.W.

    1984-01-01

    Direct titration of uranium with dipicolinic acid, in the presence of Arsenazo I, is a simple, precise, and accurate method for uranium determination. The method is particularly attractive because it can be totally automated. Detecting the end point (color change from blue to pink) depends on the concentration range. For the Micro Method (1 to 20 ppM U in the solution titrated), the gradual color change is monitored spectrophotometrically. For the Macro Method (20 to 300 ppM), the end point is determined either visually or spectrophotometrically. The spectrophotometric end point is computed by fitting the titration curve. The relative standard deviation is +-1 to 3% for the Micro Method and +-0.3% for the Macro Method

  19. Determination of dissolved inorganic species of iodine by spectrophotometric titration

    Energy Technology Data Exchange (ETDEWEB)

    Pesavento, Maria; Profumo, Antonella; Biesuz, Raffaela

    1987-09-01

    A method for determining iodate and iodine (+1) in aqueous solutions is proposed. The assay is similar to a previously described method for the determination of iodide and iodine (O), which were titrated with standard iodate in hydrochloric acid solution. A sample solution made 0.5-1.5 M in hydrochloric acid is titrated with a standard iodide solution and monitored spectrophotometrically at 230 nm. The species involved have strong absorbances that are well differentiated at this wavelength. By combining the two titrations it is possible to resolve any mixture of species of iodine in different oxidation states. The precision of the method (standard deviation) is the same both when determining a single species (IO/sub 3/-,I+,1/sub 2/ or I-) and a mixture, and is equal to 2 x 10/sup -7/ M. Chloride and bromide, even at very high concentrations, do not interfere.

  20. Determination of dissolved inorganic species of iodine by spectrophotometric titration

    International Nuclear Information System (INIS)

    Pesavento, Maria; Profumo, Antonella

    1987-01-01

    A method for determining iodate and iodine (+1) in aqueous solutions is proposed. The assay is similar to a previously described method for the determination of iodide and iodine (O), which were titrated with standard iodate in hydrochloric acid solution. A sample solution made 0.5-1.5 M in hydrochloric acid is titrated with a standard iodide solution and monitored spectrophotometrically at 230 nm. The species involved have strong absorbances that are well differentiated at this wavelength. By combining the two titrations it is possible to resolve any mixture of species of iodine in different oxidation states. The precision of the method (standard deviation) is the same both when determining a single species (IO 3 -,I+,1 2 or I-) and a mixture, and is equal to 2 x 10 -7 M. Chloride and bromide, even at very high concentrations, do not interfere. (author)

  1. Violence against Teachers: Case Studies from the APA Task Force

    Science.gov (United States)

    Reddy, Linda A.; Espelage, Dorothy; McMahon, Susan D.; Anderman, Eric M.; Lane, Kathleen Lynne; Brown, Veda Evanell; Reynolds, Cecil R.; Jones, Abraham; Kanrich, Jaclyn

    2013-01-01

    Violence directed toward teachers has been understudied despite significant media and empirical investigation on school violence, such as student-to-student victimization and bullying. To date, there are relatively few published studies scattered across many countries. To address this void, the American Psychological Association, in collaboration…

  2. Titrating decision processes in the mental rotation task.

    Science.gov (United States)

    Provost, Alexander; Heathcote, Andrew

    2015-10-01

    Shepard and Metzler's (1971) seminal mental-rotation task-which requires participants to decide if 1 object is a rotated version of another or its mirror image-has played a central role in the study of spatial cognition. We provide the first quantitative model of behavior in this task that is comprehensive in the sense of simultaneously providing an account of both error rates and the full distribution of response times. We used Brown and Heathcote's (2008) model of choice processing to separate out the contributions of mental rotation and decision stages. This model-based titration process was applied to data from a paradigm where converging evidence supported performance being based on rotation rather than other strategies. Stimuli were similar to Shepard and Metzler's block figures except a long major axis made rotation angle well defined for mirror stimuli, enabling comprehensive modeling of both mirror and normal responses. Results supported a mental rotation stage based on Larsen's (2014) model, where rotation takes a variable amount of time with a mean and variance that increase linearly with rotation angle. Differences in response threshold differences were largely responsible for mirror responses being slowed, and for errors increasing with rotation angle for some participants. (PsycINFO Database Record (c) 2015 APA, all rights reserved).

  3. Intersegmental interactions in supercoiled DNA: atomic force microscope study

    Energy Technology Data Exchange (ETDEWEB)

    Shlyakhtenko, Luda S.; Miloseska, Lela; Potaman, Vladimir N.; Sinden, Richard R.; Lyubchenko, Yuri L

    2003-10-15

    Intersegmental interactions in DNA facilitated by the neutralization of electrostatic repulsion was studied as a function of salt concentration and DNA supercoiling. DNA samples with defined superhelical densities were deposited onto aminopropyl mica at different ionic conditions and imaged in air after drying of the samples. Similar to hydrodynamic data, we did not observe a collapse of supercoiled DNA, as proposed earlier by cryo-EM studies. Instead, the formation of the contacts between DNA helices within supercoiled loops with no visible space between the duplexes was observed. The length of such close contacts increased upon increasing NaCl concentration. DNA supercoiling was a critical factor for the stabilization of intersegmental contacts. Implications of the observed effect for understanding DNA compaction in the cell and for regulation DNA transactions via interaction of distantly separated DNA regions are discussed.

  4. Air Force Leadership Study: The Need for Deliberate Development

    Science.gov (United States)

    2012-02-01

    Abraham Maslow , once the basic needs of survival and security are met, people concern themselves with higher needs like affection, be- longing, the...maintaining the data needed , and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of...Study: The Need for Deliberate Development 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e

  5. Optical ph sensing material prepared from doped sol-gel film for use in acid-base titration

    Directory of Open Access Journals (Sweden)

    Musa Ahmad

    2017-11-01

    Full Text Available An optical pH sensing material has been prepared in this study by using sol-gel technique. Bromothymol blue, bromophenol blue and thymol blue were chosen in this study as acidbase indicators for strong acid-strong base, strong acid-weak base and weak acid-strong base titration, respectively. The results show that these indicators could be successfully entrapped inside the sol-gel film and still maintain its chemical behaviour as in solution. The entrapped acid-base indicators respond well to any pH changes and could be used to determine the end-point of the acid-base titration.

  6. A test on reactive force fields for the study of silica dimerization reactions

    Energy Technology Data Exchange (ETDEWEB)

    Moqadam, Mahmoud; Riccardi, Enrico; Trinh, Thuat T.; Åstrand, Per-Olof; Erp, Titus S. van, E-mail: titus.van.erp@ntnu.no [Department of Chemistry, Norwegian University of Science and Technology (NTNU), Høgskoleringen 5, Realfagbygget D3-117, 7491 Trondheim (Norway)

    2015-11-14

    We studied silica dimerization reactions in the gas and aqueous phase by density functional theory (DFT) and reactive force fields based on two parameterizations of ReaxFF. For each method (both ReaxFF force fields and DFT), we performed constrained geometry optimizations, which were subsequently evaluated in single point energy calculations using the other two methods. Standard fitting procedures typically compare the force field energies and geometries with those from quantum mechanical data after a geometry optimization. The initial configurations for the force field optimization are usually the minimum energy structures of the ab initio database. Hence, the ab initio method dictates which structures are being examined and force field parameters are being adjusted in order to minimize the differences with the ab initio data. As a result, this approach will not exclude the possibility that the force field predicts stable geometries or low transition states which are realistically very high in energy and, therefore, never considered by the ab initio method. Our analysis reveals the existence of such unphysical geometries even at unreactive conditions where the distance between the reactants is large. To test the effect of these discrepancies, we launched molecular dynamics simulations using DFT and ReaxFF and observed spurious reactions for both ReaxFF force fields. Our results suggest that the standard procedures for parameter fitting need to be improved by a mutual comparative method.

  7. Force degradation of orthodontic latex elastics: An in-vivo study.

    Science.gov (United States)

    Qodcieh, Sadeq M Adel; Al-Khateeb, Susan N; Jaradat, Ziad W; Abu Alhaija, Elham S J

    2017-03-01

    Our objectives were to assess the force degradation of orthodontic latex elastics over 48 hours in vivo and to study the relationship between the amount of mouth opening and the degree of force decay. Fifty-two orthodontic patients wearing fixed appliances using Class II elastics were asked to wear premeasured-force 3/16-in heavy and medium intermaxillary elastics. The force amounts were measured and compared at different time intervals. Fifty percent of the force was lost after 3.9 hours for the medium elastics and after 4.9 hours for the heavy elastics. A continuous significant force drop in all elastics was seen at all time intervals (P elastics compared with the medium elastics in vivo at all time intervals (P degradation occurred in the first 4 to 5 hours. Because of breakage and for oral hygiene purposes, orthodontic elastics should be changed daily; otherwise, elastics can be used for 48 hours. Force decay of the elastics was correlated to the lateral distance between the maxillary canine and the mandibular first molar in occlusion. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  8. Effect of intrusive and retraction forces in labial and lingual orthodontics: A finite element study

    Directory of Open Access Journals (Sweden)

    Rohan Mascarenhas

    2014-01-01

    Full Text Available Objectives: Lingual orthodontics differs in biomechanics as compared to labial system and has biomechanical advantages. Although theoretical approaches have explained the differences between labial and lingual orthodontics, the finite element method (FEM may be better suited to analyze these differences. This study analyzes the effect of vertical and horizontal forces together on the tooth using FEM. Materials and Methods: An extracted right maxillary central incisor was radiographed and was used to create a solid model using ANSYS. The geometric model was converted into a finite element model with the help of ANSYS software. The model consists of 27,000 elements and 30,000 nodes. Two force vectors (vertical and horizontal were applied labially and lingually at 3 different heights- 4 mm, 5 mm and 6 mm from the incisal edge. Results: In the labial system, the net force vector passes through the center of resistance (CR and brings about intrusion. The net force vector in lingual orthodontics does not pass through the center of resistance and produces lingual tipping of the incisors. Conclusion: Intrusion and retraction forces bring about tipping of incisors in lingual orthodontics. The same amount of intrusion and retraction forces brings about intrusion of incisors in labial orthodontics. Therefore, direction and amount of forces should be carefully and judiciously applied after taking into consideration the resultant biomechanical differences.

  9. Determination of binding constants of cyclodextrin inclusion complexes with amino acids and dipeptides by potentiometric titration.

    Science.gov (United States)

    Kahle, Claudia; Holzgrabe, Ulrike

    2004-10-01

    Cyclodextrins are well known for their ability to separate enantiomers of drugs, natural products, and other chiral substances using HPLC, GC, or CE. The resolution of the enantiomers is due to the formation of diastereomeric complexes between the cyclodextrin and the pairs of enantiomers. The aim of this study was to determine the binding constants of the complexes between alpha- and beta-cyclodextrin and the enantiomers of a series of aliphatic and aromatic amino acids, and dipeptides, using a potentiometric titration method. The results of this method are compared to other methods, and correlated to findings in cyclodextrin-modified capillary electrophoresis and possible complex structures. Potentiometric titration was found to be an appropriate tool to determine the binding constants of cyclodextrin inclusion complexes.

  10. Study on force mechanism for therapeutic effect of pushing manipulation with one-finger meditation base on similarity analysis of force and waveform.

    Science.gov (United States)

    Fang, Lei; Fang, Min; Guo, Min-Min

    2016-12-27

    To reveal the force mechanism for therapeutic effect of pushing manipulation with one-finger meditation. A total of 15 participants were recruited in this study and assigned to an expert group, a skilled group and a novice group, with 5 participants in each group. Mechanical signals were collected from a biomechanical testing platform, and these data were further observed via similarity analysis and cluster analysis. Comparing the force waveforms of manipulation revealed that the manipulation forces were similar between the expert group and the skilled group (P>0.05). The mean value of vertical force was 9.8 N, and 95% CI rang from 6.37 to 14.70 N, but there were significant differences compared with the novice group (PPushing manipulation with one-finger meditation is a kind of light stimulation manipulation on the acupoint, and force characteristics of double waveforms continuously alternated during manual operation.

  11. Cellulose fibril aggregation studies of eucalyptus dissolving pulps using atomic force microscopy

    CSIR Research Space (South Africa)

    Chunilall, Viren

    2006-11-01

    Full Text Available STUDIES OF Eucalyptus DISSOLVING PULPS USING ATOMIC FORCE MICROSCOPY V. Chunilall1, J.Wesley-Smith2, T. Bush1 1CSIR, Forestry and Forest Product Research Centre, P.O. Box 17001, Congella, 4013, South Africa. 2Electron Microscope Unit, University of Kwa... pulp using atomic force microscopy (AFM) have reported increased cellulose fibril aggregation during processing, and a concomitant decrease in surface area available for chemical reaction1,2. These findings were subsequently confirmed...

  12. A Case Study On Human Capital Mismanagement In The United States Air Force

    Science.gov (United States)

    2016-05-08

    AIR COMMAND AND STAFF COLLEGE AIR UNIVERSITY A Case Study on Human Capital Mismanagement in the United States Air Force By John P...Force does not effectively manage its human capital to develop and retain a technically literate acquisitions workforce. A detailed look at the...Several solutions are suggested to improve the human capital management and increase the quality and relevancy of the acquisitions community at

  13. Labor force participation in later life: Evidence from a cross-sectional study in Thailand

    OpenAIRE

    Soonthorndhada Kusol; Adhikari Ramesh; Haseen Fariha

    2011-01-01

    Abstract Background The labor force participation rate is an important indicator of the state of the labor market and a major input into the economy's potential for creating goods and services. The objectives of this paper are to examine the prevalence of labor force participation among older people in Thailand and to investigate the factors affecting this participation. Methods The data for this study were drawn from the '2007 Survey of Older Persons' in Thailand. Bivariate analysis was used...

  14. Quantitative study of FORC diagrams in thermally corrected Stoner– Wohlfarth nanoparticles systems

    International Nuclear Information System (INIS)

    De Biasi, E.; Curiale, J.; Zysler, R.D.

    2016-01-01

    The use of FORC diagrams is becoming increasingly popular among researchers devoted to magnetism and magnetic materials. However, a thorough interpretation of this kind of diagrams, in order to achieve quantitative information, requires an appropriate model of the studied system. For that reason most of the FORC studies are used for a qualitative analysis. In magnetic systems thermal fluctuations 'blur' the signatures of the anisotropy, volume and particle interactions distributions, therefore thermal effects in nanoparticles systems conspire against a proper interpretation and analysis of these diagrams. Motivated by this fact, we have quantitatively studied the degree of accuracy of the information extracted from FORC diagrams for the special case of single-domain thermal corrected Stoner– Wohlfarth (easy axes along the external field orientation) nanoparticles systems. In this work, the starting point is an analytical model that describes the behavior of a magnetic nanoparticles system as a function of field, anisotropy, temperature and measurement time. In order to study the quantitative degree of accuracy of our model, we built FORC diagrams for different archetypical cases of magnetic nanoparticles. Our results show that from the quantitative information obtained from the diagrams, under the hypotheses of the proposed model, is possible to recover the features of the original system with accuracy above 95%. This accuracy is improved at low temperatures and also it is possible to access to the anisotropy distribution directly from the FORC coercive field profile. Indeed, our simulations predict that the volume distribution plays a secondary role being the mean value and its deviation the only important parameters. Therefore it is possible to obtain an accurate result for the inversion and interaction fields despite the features of the volume distribution. - Highlights: • Quantify the degree of accuracy of the information obtained using the FORC diagrams.

  15. Comparison of NO titration and fiber optics catalytic probes for determination of neutral oxygen atom concentration in plasmas and postglows

    International Nuclear Information System (INIS)

    Mozetic, Miran; Ricard, Andre; Babic, Dusan; Poberaj, Igor; Levaton, Jacque; Monna, Virginie; Cvelbar, Uros

    2003-01-01

    A comparative study of two different absolute methods NO titration and fiber optics catalytic probe (FOCP) for determination of neutral oxygen atom density is presented. Both methods were simultaneously applied for measurements of O density in a postglow of an Ar/O 2 plasma created by a surfatron microwave generator with the frequency of 2.45 GHz an adjustable output power between 30 and 160 W. It was found that the two methods gave similar results. The advantages of FOCP were found to be as follows: it is a nondestructive method, it enables real time measuring of the O density, it does not require any toxic gas, and it is much faster than NO titration. The advantage of NO titration was found to be the ability to measure O density in a large range of dissociation of oxygen molecules

  16. Comparison of vertical ground reaction forces during overground and treadmill running. A validation study

    Directory of Open Access Journals (Sweden)

    Kluitenberg Bas

    2012-11-01

    Full Text Available Abstract Background One major drawback in measuring ground-reaction forces during running is that it is time consuming to get representative ground-reaction force (GRF values with a traditional force platform. An instrumented force measuring treadmill can overcome the shortcomings inherent to overground testing. The purpose of the current study was to determine the validity of an instrumented force measuring treadmill for measuring vertical ground-reaction force parameters during running. Methods Vertical ground-reaction forces of experienced runners (12 male, 12 female were obtained during overground and treadmill running at slow, preferred and fast self-selected running speeds. For each runner, 7 mean vertical ground-reaction force parameters of the right leg were calculated based on five successful overground steps and 30 seconds of treadmill running data. Intraclass correlations (ICC(3,1 and ratio limits of agreement (RLOA were used for further analysis. Results Qualitatively, the overground and treadmill ground-reaction force curves for heelstrike runners and non-heelstrike runners were very similar. Quantitatively, the time-related parameters and active peak showed excellent agreement (ICCs between 0.76 and 0.95, RLOA between 5.7% and 15.5%. Impact peak showed modest agreement (ICCs between 0.71 and 0.76, RLOA between 19.9% and 28.8%. The maximal and average loading-rate showed modest to excellent ICCs (between 0.70 and 0.89, but RLOA were higher (between 34.3% and 45.4%. Conclusions The results of this study demonstrated that the treadmill is a moderate to highly valid tool for the assessment of vertical ground-reaction forces during running for runners who showed a consistent landing strategy during overground and treadmill running. The high stride-to-stride variance during both overground and treadmill running demonstrates the importance of measuring sufficient steps for representative ground-reaction force values. Therefore, an

  17. Individualized toxicity-titrated 6-mercaptopurine increments during high-dose methotrexate consolidation treatment of lower risk childhood acute lymphoblastic leukemia

    DEFF Research Database (Denmark)

    Frandsen, Thomas Leth; Abrahamsson, Jonas; Lausen, Birgitte Frederiksen

    2011-01-01

    This study explored the feasibility and toxicity of individualized toxicity-titrated 6-mercaptopurine (6MP) dose increments during post-remission treatment with High-dose methotrexate (HDM) (5000 mg/m2, ×3) in 38 patients with Childhood (ALL). Patients were increased in steps of 25 mg 6MP/m2 per...... the remaining patients (P = 0·03). This study shows individualized toxicity-titrated 6MP dosing during consolidation is feasible without increased risk of toxicity....

  18. A study on the changes in attractive force of magnetic attachments for overdenture.

    Science.gov (United States)

    Leem, Han-Wool; Cho, In-Ho; Lee, Jong-Hyuk; Choi, Yu-Sung

    2016-02-01

    Although magnetic attachment is used frequently for overdenture, it is reported that attractive force can be decreased by abrasion and corrosion. The purpose of this study was to establish the clinical basis about considerations and long term prognosis of overdenture using magnetic attachments by investigating the change in attractive force of magnetic attachment applied to the patients. Among the patients treated with overdenture using magnetic attachments in Dankook University Dental Hospital, attractive force records of 61 magnetic attachments of 20 subjects who re-visited from July 2013 to June 2014 were analyzed. Dental magnet tester (Aichi Micro Intelligent Co., Aichi, Japan) was used for measurement. The magnetic attachments used in this study were Magfit IP-B Flat, Magfit DX400, Magfit DX600 and Magfit DX800 (Aichi Steel Co., Aichi, Japan) filled with Neodymium (NdFeB), a rare-earth magnet. Reduction ratio of attractive force had no significant correlation with conditional variables to which attachments were applied, and was higher when the maintenance period was longer (Pattractive force was significantly higher in the subject group in which attachments were used over 9 years than within 9 years (PAttractive force of magnetic attachment is maintained regardless of conditional variables and reduction ratio increased as the maintenance period became longer. Further study on adhesive material, attachment method and design improvement to prevent detachment of magnetic attachment is needed.

  19. Tip-Loading, Force-Dependent Tunneling Behavior in Alkanethiol Self-Assembled Monolayers Studied Through Conducting Atomic Force Microscopy

    International Nuclear Information System (INIS)

    Lee, Min Hyung; Song, Hyun Wook

    2013-01-01

    The force-dependent tunneling transport in metal/alkanethiol/metal junctions was examined using CAFM. Tunneling current and current density through alkanethiol SAMs increased with increasing tip-loading force in CAFM, which suggests that a potential change in geometry of the molecules under the tip loads influences the transport properties of alkanethiol SAMs. Enhanced intermolecular tunneling transport in the tilted molecular configuration under tip-loading effect is likely responsible for such an increase in tunneling current density. We also demonstrated that through-bond tunneling is a more efficient pathway in alkanethiol SAMs than are intermolecular chain-to-chain pathways, by demonstrating a dependence of current density on the associated tunneling distances. We report a tip-loading, force-dependent tunneling behavior in alkanethiol SAMs using CAFM. A variable tip-loading force applies to alkanethiol SAMs with a standard AFM feedback, and current(I)-voltage(V) characteristics are simultaneously measured while varying the loading forces. In particular, we observe how a tip-loading force in CAFM influences the transport properties of alkanethiol SAMs

  20. Construction and use of an optical semi-automatic titrator employing the technique of reflectance photometry

    International Nuclear Information System (INIS)

    Hwang, Hoon

    2001-01-01

    An optical semi-automatic titrator was constructed employing the technique of the reflectance spectrometry and was tested for the determination of the end points of the acid-base, precipitation, and EDTA titrations. And since the current optical semi-automatic titrator built on the principle of the reflectance spectrometry could be successfully used even for the determination of the end of the end point in the precipitation titration where the solid particles are formed during the titration process, it was found to be feasible that a completely automated optical titrator would be designed and built based on the current findings

  1. Empiric auto-titrating CPAP in people with suspected obstructive sleep apnea.

    Science.gov (United States)

    Drummond, Fitzgerald; Doelken, Peter; Ahmed, Qanta A; Gilbert, Gregory E; Strange, Charlie; Herpel, Laura; Frye, Michael D

    2010-04-15

    Efficient diagnosis and treatment of obstructive sleep apnea (OSA) can be difficult because of time delays imposed by clinic visits and serial overnight polysomnography. In some cases, it may be desirable to initiate treatment for suspected OSA prior to polysomnography. Our objective was to compare the improvement of daytime sleepiness and sleep-related quality of life of patients with high clinical likelihood of having OSA who were randomly assigned to receive empiric auto-titrating continuous positive airway pressure (CPAP) while awaiting polysomnogram versus current usual care. Serial patients referred for overnight polysomnography who had high clinical likelihood of having OSA were randomly assigned to usual care or immediate initiation of auto-titrating CPAP. Epworth Sleepiness Scale (ESS) scores and the Functional Outcomes of Sleep Questionnaire (FOSQ) scores were obtained at baseline, 1 month after randomization, and again after initiation of fixed CPAP in control subjects and after the sleep study in auto-CPAP patients. One hundred nine patients were randomized. Baseline demographics, daytime sleepiness, and sleep-related quality of life scores were similar between groups. One-month ESS and FOSQ scores were improved in the group empirically treated with auto-titrating CPAP. ESS scores improved in the first month by a mean of -3.2 (confidence interval -1.6 to -4.8, p life in a cohort of patients awaiting polysomnography who had a high pretest probability of having OSA. Additional studies are needed to evaluate the applicability of empiric treatment to other populations.

  2. Study of even-Z nuclei up to Mg with the Gogny force using AMD

    Energy Technology Data Exchange (ETDEWEB)

    Sugawa, Yoshio; Kimura, Masaaki; Horiuchi, Hisashi [Kyoto Univ. (Japan). Dept. of Physics

    2001-12-01

    Employing the Gogny force as an effective force, we study the ground state properties of light nuclei using antisymmetrized molecular dynamics (AMD). In this study, we are mainly concerned with the binding energies and radii of light even-Z isotopes, namely He, Be, C, O, Ne and Mg. Using a new technique to calculate the density dependent term of the effective force, we have realized fast and accurate calculations. From a comparison with Skyrme SIII results within the same AMD framework, we find that the Gogny and SIII forces well reproduce the experimental binding energies of stable nuclei. The two forces give almost equal radii, except in the case of {sup 7}Be and {sup 9}Be. For both forces, approximate treatment of the center-of-mass kinetic energy causes overestimation of the binding energy compared with the exact treatment. It also causes a decrease of the nuclear deformation compared with the exact treatment. We also carry out an energy variation after the parity projection. With regard to the binding energies and radii, parity-projected calculations do not exhibit a large difference compared to non-projected results, although the density distribution and clustering features are often significantly changed by the parity projection. (author)

  3. Study of even-Z nuclei up to Mg with the Gogny force using AMD

    International Nuclear Information System (INIS)

    Sugawa, Yoshio; Kimura, Masaaki; Horiuchi, Hisashi

    2001-01-01

    Employing the Gogny force as an effective force, we study the ground state properties of light nuclei using antisymmetrized molecular dynamics (AMD). In this study, we are mainly concerned with the binding energies and radii of light even-Z isotopes, namely He, Be, C, O, Ne and Mg. Using a new technique to calculate the density dependent term of the effective force, we have realized fast and accurate calculations. From a comparison with Skyrme SIII results within the same AMD framework, we find that the Gogny and SIII forces well reproduce the experimental binding energies of stable nuclei. The two forces give almost equal radii, except in the case of 7 Be and 9 Be. For both forces, approximate treatment of the center-of-mass kinetic energy causes overestimation of the binding energy compared with the exact treatment. It also causes a decrease of the nuclear deformation compared with the exact treatment. We also carry out an energy variation after the parity projection. With regard to the binding energies and radii, parity-projected calculations do not exhibit a large difference compared to non-projected results, although the density distribution and clustering features are often significantly changed by the parity projection. (author)

  4. Does combined strength training and local vibration improve isometric maximum force? A pilot study.

    Science.gov (United States)

    Goebel, Ruben; Haddad, Monoem; Kleinöder, Heinz; Yue, Zengyuan; Heinen, Thomas; Mester, Joachim

    2017-01-01

    The aim of the study was to determine whether a combination of strength training (ST) and local vibration (LV) improved the isometric maximum force of arm flexor muscles. ST was applied to the left arm of the subjects; LV was applied to the right arm of the same subjects. The main aim was to examine the effect of LV during a dumbbell biceps curl (Scott Curl) on isometric maximum force of the opposite muscle among the same subjects. It is hypothesized, that the intervention with LV produces a greater gain in isometric force of the arm flexors than ST. Twenty-seven collegiate students participated in the study. The training load was 70% of the individual 1 RM. Four sets with 12 repetitions were performed three times per week during four weeks. The right arm of all subjects represented the vibration trained body side (VS) and the left arm served as the traditional trained body side (TTS). A significant increase of isometric maximum force in both body sides (Arms) occurred. VS, however, significantly increased isometric maximum force about 43% in contrast to 22% of the TTS. The combined intervention of ST and LC improves isometric maximum force of arm flexor muscles. III.

  5. Dispersion Forces

    CERN Document Server

    Buhmann, Stefan Yoshi

    2012-01-01

    In this book, a modern unified theory of dispersion forces on atoms and bodies is presented which covers a broad range of advanced aspects and scenarios. Macroscopic quantum electrodynamics is shown to provide a powerful framework for dispersion forces which allows for discussing general properties like their non-additivity and the relation between microscopic and macroscopic interactions. It is demonstrated how the general results can be used to obtain dispersion forces on atoms in the presence of bodies of various shapes and materials. Starting with a brief recapitulation of volume I, this volume II deals especially with bodies of irregular shapes, universal scaling laws, dynamical forces on excited atoms, enhanced forces in cavity quantum electrodynamics, non-equilibrium forces in thermal environments and quantum friction. The book gives both the specialist and those new to the field a thorough overview over recent results in the field. It provides a toolbox for studying dispersion forces in various contex...

  6. Molecular dynamics study of the nanosized droplet spreading: The effect of the contact line forces on the kinetic energy dissipation

    International Nuclear Information System (INIS)

    Yoon, Hong Min; Kondaraju, Sasidhar; Lee, Jung Shin; Suh, Youngho; Lee, Joonho H.; Lee, Joon Sang

    2017-01-01

    Highlights: • Contact line forces, including friction and spreading forces are directly calculated. • Overall trends of variations in contact line forces during droplet spreading process show characteristics of contact line forces. • Detail relations of contact line forces and atomic kinetics in the contact line provide a clear evidence of the possible energy dissipation mechanism in droplet spreading process. - Abstract: Recent studies have revealed that contact line forces play an important role in the droplet spreading process. Despite their significance, the physics related to them has been studied only indirectly and the effect of contact line forces is still being disputed. We performed a molecular dynamics simulation and mimicked the droplet spreading process at the nanoscale. Based on the results of the simulation, the contact line forces were directly calculated. We found that the forces acting on the bulk and the contact line region showed different trends. Distinct positive and negative forces, contact line spreading, and friction forces were observed near the contact line. We also observed a strong dependency of the atomic kinetics in the contact line region on the variations in the contact line forces. The atoms of the liquid in the contact line region lost their kinetic energy due to the contact line friction force and became partially immobile on the solid surface. The results of the current study will be useful for understanding the role of the contact line forces on the kinetic energy dissipation in the contact line region.

  7. Molecular dynamics study of the nanosized droplet spreading: The effect of the contact line forces on the kinetic energy dissipation

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Hong Min [Department of Mechanical Engineering, Yonsei University, Seoul 120-749 (Korea, Republic of); Kondaraju, Sasidhar [Department of Mechanical Science, Indian Institute of Technology Bhubaneswar, Bhubaneswar, Odisha 751013 (India); Lee, Jung Shin [Department of Mechanical Engineering, Yonsei University, Seoul 120-749 (Korea, Republic of); Suh, Youngho; Lee, Joonho H. [Samsung Electronics, Mechatronics R& D Center, Hwaseong-si, Gyeonggi-do 445-330 (Korea, Republic of); Lee, Joon Sang, E-mail: joonlee@yonsei.ac.kr [Department of Mechanical Engineering, Yonsei University, Seoul 120-749 (Korea, Republic of)

    2017-07-01

    Highlights: • Contact line forces, including friction and spreading forces are directly calculated. • Overall trends of variations in contact line forces during droplet spreading process show characteristics of contact line forces. • Detail relations of contact line forces and atomic kinetics in the contact line provide a clear evidence of the possible energy dissipation mechanism in droplet spreading process. - Abstract: Recent studies have revealed that contact line forces play an important role in the droplet spreading process. Despite their significance, the physics related to them has been studied only indirectly and the effect of contact line forces is still being disputed. We performed a molecular dynamics simulation and mimicked the droplet spreading process at the nanoscale. Based on the results of the simulation, the contact line forces were directly calculated. We found that the forces acting on the bulk and the contact line region showed different trends. Distinct positive and negative forces, contact line spreading, and friction forces were observed near the contact line. We also observed a strong dependency of the atomic kinetics in the contact line region on the variations in the contact line forces. The atoms of the liquid in the contact line region lost their kinetic energy due to the contact line friction force and became partially immobile on the solid surface. The results of the current study will be useful for understanding the role of the contact line forces on the kinetic energy dissipation in the contact line region.

  8. Clinical predictors of central sleep apnea evoked by positive airway pressure titration.

    Science.gov (United States)

    Moro, Marilyn; Gannon, Karen; Lovell, Kathy; Merlino, Margaret; Mojica, James; Bianchi, Matt T

    2016-01-01

    Treatment-emergent central sleep apnea (TECSA), also called complex apnea, occurs in 5%-15% of sleep apnea patients during positive airway pressure (PAP) therapy, but the clinical predictors are not well understood. The goal of this study was to explore possible predictors in a clinical sleep laboratory cohort, which may highlight those at risk during clinical management. We retrospectively analyzed 728 patients who underwent PAP titration (n=422 split-night; n=306 two-night). Demographics and self-reported medical comorbidities, medications, and behaviors as well as standard physiological parameters from the polysomnography (PSG) data were analyzed. We used regression analysis to assess predictors of binary presence or absence of central apnea index (CAI) ≥5 during split-night PSG (SN-PSG) versus full-night PSG (FN-PSG) titrations. CAI ≥5 was present in 24.2% of SN-PSG and 11.4% of FN-PSG patients during titration. Male sex, maximum continuous positive airway pressure, and use of bilevel positive airway pressure were predictors of TECSA, and rapid eye movement dominance was a negative predictor, for both SN-PSG and FN-PSG patients. Self-reported narcotics were a positive predictor of TECSA, and the time spent in stage N2 sleep was a negative predictor only for SN-PSG patients. Self-reported history of stroke and the CAI during the diagnostic recording predicted TECSA only for FN-PSG patients. Clinical predictors of treatment-evoked central apnea spanned demographic, medical history, sleep physiology, and titration factors. Improved predictive models may be increasingly important as diagnostic and therapeutic modalities move away from the laboratory setting, even as PSG remains the gold standard for characterizing primary central apnea and TECSA.

  9. Flow cytometry as an improved method for the titration of Chlamydiaceae and other intracellular bacteria.

    Science.gov (United States)

    Käser, T; Pasternak, J A; Hamonic, G; Rieder, M; Lai, K; Delgado-Ortega, M; Gerdts, V; Meurens, F

    2016-05-01

    Chlamydiaceae is a family of intracellular bacteria causing a range of diverse pathological outcomes. The most devastating human diseases are ocular infections with C. trachomatis leading to blindness and genital infections causing pelvic inflammatory disease with long-term sequelae including infertility and chronic pelvic pain. In order to enable the comparison of experiments between laboratories investigating host-chlamydia interactions, the infectious titer has to be determined. Titer determination of chlamydia is most commonly performed via microscopy of host cells infected with a serial dilution of chlamydia. However, other methods including fluorescent ELISpot (Fluorospot) and DNA Chip Scanning Technology have also been proposed to enumerate chlamydia-infected cells. For viruses, flow cytometry has been suggested as a superior alternative to standard titration methods. In this study we compared the use of flow cytometry with microscopy and Fluorospot for the titration of C. suis as a representative of other intracellular bacteria. Titer determination via Fluorospot was unreliable, while titration via microscopy led to a linear read-out range of 16 - 64 dilutions and moderate reproducibility with acceptable standard deviations within and between investigators. In contrast, flow cytometry had a vast linear read-out range of 1,024 dilutions and the lowest standard deviations given a basic training in these methods. In addition, flow cytometry was faster and material costs were lower compared to microscopy. Flow cytometry offers a fast, cheap, precise, and reproducible alternative for the titration of intracellular bacteria like C. suis. © 2016 International Society for Advancement of Cytometry. © 2016 International Society for Advancement of Cytometry.

  10. Clinical Effectiveness and Dose Titration in Pediatric Practice

    Directory of Open Access Journals (Sweden)

    Yu.V. Marushko

    2016-02-01

    Full Text Available The paper is devoted to the questions of usage of one of the popular antipyretic and anesthetic drug in pediatric practice — ibuprofen. In the article there are generalized literature data and own experience in ibuprofen dose titration in single dose 5 and 10 mg/kg depending on clinical situation.

  11. Uranium coulometric titration. Application to the determination of traces

    International Nuclear Information System (INIS)

    Bergey, C.

    After a description of the device, the means developed to improve the titration method are presented. Coulometry enables to determine U with an accuracy of 0,1% in samples of only several tenths of a milligram. This method is rapid but not intended for routine analysis [fr

  12. Isothermal Titration Calorimetry Can Provide Critical Thinking Opportunities

    Science.gov (United States)

    Moore, Dale E.; Goode, David R.; Seney, Caryn S.; Boatwright, Jennifer M.

    2016-01-01

    College chemistry faculties might not have considered including isothermal titration calorimetry (ITC) in their majors' curriculum because experimental data from this instrumental method are often analyzed via automation (software). However, the software-based data analysis can be replaced with a spreadsheet-based analysis that is readily…

  13. A dipstick sensor for coulometric acid-base titrations

    NARCIS (Netherlands)

    Olthuis, Wouter; van der Schoot, B.H.; Chavez, F.; Bergveld, Piet

    1989-01-01

    By performing an acid-base titration by coulometric generation of OH− or H+ ions at an inert electrode in close proximity to the pH-sensitive gate of an ISFET, it is possible to determine the acid or base concentration of a solution using the ISFET as an indicator device for the equivalence point in

  14. Using Spreadsheets to Produce Acid-Base Titration Curves.

    Science.gov (United States)

    Cawley, Martin James; Parkinson, John

    1995-01-01

    Describes two spreadsheets for producing acid-base titration curves, one uses relatively simple cell formulae that can be written into the spreadsheet by inexperienced students and the second uses more complex formulae that are best written by the teacher. (JRH)

  15. Developing and Demonstrating an Augmented Reality Colorimetric Titration Tool

    Science.gov (United States)

    Tee, Nicholas Yee Kwang; Gan, Hong Seng; Li, Jonathan; Cheong, Brandon Huey-Ping; Tan, Han Yen; Liew, Oi Wah; Ng, Tuck Wah

    2018-01-01

    The handling of chemicals in the laboratory presents a challenge in instructing large class sizes and when students are relatively new to the laboratory environment. In this work, we describe and demonstrate an augmented reality colorimetric titration tool that operates out of the smartphone or tablet of students. It allows multiple students to…

  16. Automation of potentiometric titration with a personal computer using ...

    African Journals Online (AJOL)

    sampling was designed and tested for automation of potentiometric titrations with personal ... automation permits us to carry out new types of experiments, such as those requiring ... have proved to be very useful in routine tasks but not in research, due to their ... This is done by a simple delay sub-routine in data acquisition.

  17. A General Simulator for Acid-Base Titrations

    Science.gov (United States)

    de Levie, Robert

    1999-07-01

    General formal expressions are provided to facilitate the automatic computer calculation of acid-base titration curves of arbitrary mixtures of acids, bases, and salts, without and with activity corrections based on the Davies equation. Explicit relations are also given for the buffer strength of mixtures of acids, bases, and salts.

  18. pH-metric solubility. 3. Dissolution titration template method for solubility determination.

    Science.gov (United States)

    Avdeef, A; Berger, C M

    2001-12-01

    The main objective of this study was to develop an effective potentiometric saturation titration protocol for determining the aqueous intrinsic solubility and the solubility-pH profile of ionizable molecules, with the specific aim of overcoming incomplete dissolution conditions, while attempting to shorten the data collection time. A modern theory of dissolution kinetics (an extension of the Noyes-Whitney approach) was applied to acid-base titration experiments. A thermodynamic method was developed, based on a three-component model, to calculate interfacial, diffusion-layer, and bulk-water reactant concentrations in saturated solutions of ionizable compounds perturbed by additions of acid/base titrant, leading to partial dissolution of the solid material. Ten commercial drugs (cimetidine, diltiazem hydrochloride, enalapril maleate, metoprolol tartrate, nadolol, propoxyphene hydrochloride, quinine hydrochloride, terfenadine, trovafloxacin mesylate, and benzoic acid) were chosen to illustrate the new titration methodology. It was shown that the new method is about 10 times faster in determining equilibrium solubility constants, compared to the traditional saturation shake-flask methods.

  19. The efficacy of three different mask styles on a PAP titration night.

    Science.gov (United States)

    Ebben, Matthew R; Oyegbile, Temitayo; Pollak, Charles P

    2012-06-01

    This study compared the efficacy of three different masks, nasal pillows, nasal masks and full face (oronasal) masks, during a single night of titration with continuous positive airway pressure (CPAP). Fifty five subjects that included men (n=33) and women (n=22) were randomly assigned to one of three masks and underwent a routine titration with incremental CPAP applied through the different masks. CPAP applied through the nasal pillows and nasal mask was equally effective in treating mild, moderate, and severe sleep apnea. However, CPAP applied through the oronasal mask required a significantly higher pressure compared to nasal masks to treat moderately severe (2.8 cm of H(2)O ± 2.1 SD) and severe (6.0 cm of H(2)O ± 3.2 SD) obstructive sleep apnea. CPAP applied with either nasal mask was effective in treating mild, moderate, and severe sleep apnea. The oronasal mask required significantly higher pressures in subjects with moderate to severe disease. Therefore, when changing from a nasal to an oronasal mask, a repeat titration is required to ensure effective treatment of sleep apnea, especially in patients with moderate to severe disease. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Reference method for total water in lint cotton by automated oven drying combined with volumetric Karl Fischer titration

    Science.gov (United States)

    In a preliminary study to measure total water in lint cotton we demonstrated that volumetric Karl Fischer Titration of moisture transported by a carrier gas from an attached small oven is more accurate than standard oven drying in air. The objective of the present study was to assess the measuremen...

  1. Study of Radiative Forcing of Dust Aerosols and its impact on Climate Characteristics

    KAUST Repository

    Qureshi, Fawwad H

    2012-12-01

    The purpose of following project is to study the effect of dust aerosols on the radiative forcing which is directly related to the surface temperature. A single column radiative convective model is used for simulation purpose. A series of simulations have been performed by varying the amount of dust aerosols present in the atmosphere to study the trends in ground temperature, heating rate and radiative forcing for both its longwave and shortwave components. A case study for dust storm is also performed as dust storms are common in Arabian Peninsula. A sensitivity analyses is also performed to study the relationship of surface temperature minimum and maximum against aerosol concentration, single scattering albedo and asymmetry factor. These analyses are performed to get more insight into the role of dust aerosols on radiative forcing.

  2. Marital status, labour force activity and mortality: a study in the USA and six European countries.

    Science.gov (United States)

    Van Hedel, Karen; Van Lenthe, Frank J; Avendano, Mauricio; Bopp, Matthias; Esnaola, Santiago; Kovács, Katalin; Martikainen, Pekka; Regidor, Enrique; Mackenbach, Johan P

    2015-07-01

    Labour force activity and marriage share some pathways through which they potentially influence health. In this paper, we examine whether marriage and labour force participation interact in the way they influence mortality in the USA and six European countries. We used data from the US National Health Interview Survey linked to the National Death Index, and national mortality registry data for Austria, England/Wales, Finland, Hungary, Norway and Spain (specifically, the Basque country) during 1999-2007, for men and women aged 30-59 years at baseline. We used Poisson regression to estimate both the additive (relative excess risk due to interaction) and multiplicative interactions between marriage and labour force activity on mortality. Labour force inactivity was associated with higher mortality, but this association was stronger for unmarried, rather than married, individuals. Likewise, being unmarried was associated with higher mortality, but this association was stronger for inactive than for active individuals. To illustrate, among US women out of the labour force, being unmarried was associated with a 3.98 times (95%CI 3.28-4.82) higher risk of dying than being married; whereas the relative risk (RR) was 2.49 (95%CI 2.10-2.94), for women who were active in the labour market. Although this interaction between marriage and labour force activity was only significant for women on a multiplicative scale, there was a significant additive interaction for both men and women. The pattern was similar across all countries. Marriage attenuated the increased mortality risk associated with labour force inactivity; while labour force activity attenuated the mortality risk associated with being unmarried. Our study emphasizes the importance of public health and social policies that improve the health and well-being of unmarried and inactive men and women. © 2015 the Nordic Societies of Public Health.

  3. Postural And Eye-Positional Effects On Human Biting Force: An Experimental Study

    Directory of Open Access Journals (Sweden)

    Altay Tabancacı

    2012-06-01

    Full Text Available Muscle groups affected on biting force are called temporal muscle as a major and masseter muscle as a minor. According to the human posture stability, forces of these muscles vary with the force directions. In this case, experimental investigation is strictly important such that biting force under different postural and eye- positional situations is changed. In this study, seven-male and seven-female within the age-range of 17-24 are considered corresponding to having with restorated molar tooth and without that type of tooth. With the help of specially designed biting fork, different posture- and eye-positions are investigated for experimental biting force analysis. Changes in eye-positions are not indicated significant difference for all postural positions. On one hand, it is obtained that biting force of no-filling tooth in men becomes maximum if facial muscles give full effort to biting. On the other hand, effect of facial muscles for women is not clearly noticed depending on the postural differences.

  4. Force majeure clauses and the threat of nuclear disaster. A Japanese case study

    Energy Technology Data Exchange (ETDEWEB)

    Guderian, Stephan Michael

    2011-07-22

    Force majeure clauses can be found in any commercial contract. Though more or less clear guidelines for the applicability of force majeure (clauses) exist in the form of international and national law, the applicability and enforceability of force majeure clauses with respect to nuclear incidents or disasters, however, remain ambiguous. Until the Japanese nuclear disaster, no major trade region was affected by any of the historical nuclear incidents. This case-study is based on the events surrounding the Tohoku earthquake, respective tsunami and nuclear incidents, especially at the Daiichi NPP and radiological contamination released there. The applicability and enforceability of force majeure clauses with their wide legal and economical implications are analyzed and evaluated according to the CISG and national domestic Japanese law. It is found that the assertion of force majeure is generally highly fact-specific and circumstance-sensitive. In general, the potential of nuclear disaster as an event triggering the force majeure defence is clearly evident, according to both international and Japanese law. Any claim must, however, be substantiated according to the principles of the different legal regimes under which the contract falls. In consequence, a company located within the evacuated areas will probably be able to successfully assert for majeure, whilst the success of any other claim will depend on the presentation of evidence, such as radiation levels and its effects in hindering performance of contractual obligations.

  5. Force majeure clauses and the threat of nuclear disaster. A Japanese case study

    International Nuclear Information System (INIS)

    Guderian, Stephan Michael

    2011-01-01

    Force majeure clauses can be found in any commercial contract. Though more or less clear guidelines for the applicability of force majeure (clauses) exist in the form of international and national law, the applicability and enforceability of force majeure clauses with respect to nuclear incidents or disasters, however, remain ambiguous. Until the Japanese nuclear disaster, no major trade region was affected by any of the historical nuclear incidents. This case-study is based on the events surrounding the Tohoku earthquake, respective tsunami and nuclear incidents, especially at the Daiichi NPP and radiological contamination released there. The applicability and enforceability of force majeure clauses with their wide legal and economical implications are analyzed and evaluated according to the CISG and national domestic Japanese law. It is found that the assertion of force majeure is generally highly fact-specific and circumstance-sensitive. In general, the potential of nuclear disaster as an event triggering the force majeure defence is clearly evident, according to both international and Japanese law. Any claim must, however, be substantiated according to the principles of the different legal regimes under which the contract falls. In consequence, a company located within the evacuated areas will probably be able to successfully assert for majeure, whilst the success of any other claim will depend on the presentation of evidence, such as radiation levels and its effects in hindering performance of contractual obligations.

  6. Evaluation of modified boehm titration methods for use with biochars.

    Science.gov (United States)

    Fidel, Rivka B; Laird, David A; Thompson, Michael L

    2013-11-01

    The Boehm titration, originally developed to quantify organic functional groups of carbon blacks and activated carbons in discrete pK ranges, has received growing attention for analyzing biochar. However, properties that distinguish biochar from carbon black and activated carbon, including greater carbon solubility and higher ash content, may render the original Boehm titration method unreliable for use with biochars. Here we use seven biochars and one reference carbon black to evaluate three Boehm titration methods that use (i) acidification followed by sparging (sparge method), (ii) centrifugation after treatment with BaCl (barium method), and (iii) a solid-phase extraction cartridge followed by acidification and sparging (cartridge method) to remove carbonates and dissolved organic compounds (DOC) from the Boehm extracts before titration. Our results for the various combinations of Boehm reactants and methods indicate that no one method was free of bias for all three Boehm reactants and that the cartridge method showed evidence of bias for all pK ranges. By process of elimination, we found that a combination of the sparge method for quantifying functional groups in the lowest pK range (∼5 to 6.4), and the barium method for quantifying functional groups in the higher pK ranges (∼6.4 to 10.3 and ∼10.3 to 13) to be free of evidence for bias. We caution, however, that further testing is needed and that all Boehm titration results for biochars should be considered suspect unless efforts were undertaken to remove ash and prevent interference from DOC. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  7. Prediction of Peak Back Compressive Forces as a Function of Lifting Speed and Compressive Forces at Lift Origin and Destination - A Pilot Study

    Directory of Open Access Journals (Sweden)

    Kasey O. Greenland

    2011-09-01

    Conclusion: SODA under-predict both static and dynamic peak back-compressive force values. Peak values are highly predictable and could be readily determined using back-compressive force assessments at the origin and destination of a lifting task. This could be valuable for enhancing job design and analysis in the workplace and for large-scale studies where a full analysis of each lifting task is not feasible.

  8. When acid-base titrations are carried out in unusual conditions

    Directory of Open Access Journals (Sweden)

    Domenico De Marco

    2012-12-01

    Full Text Available Uncommon aspects in acid-base titrations are presented, which occur in titrations between both mono- and/or poly-functional acid and bases but are rarely introduced in ordinary analytical chemistry courses.

  9. Numerical study of the lateral resolution in electrostatic force microscopy for dielectric samples

    International Nuclear Information System (INIS)

    Riedel, C; AlegrIa, A; Colmenero, J; Schwartz, G A; Saenz, J J

    2011-01-01

    We present a study of the lateral resolution in electrostatic force microscopy for dielectric samples in both force and gradient modes. Whereas previous studies have reported expressions for metallic surfaces having potential heterogeneities (Kelvin probe force microscopy), in this work we take into account the presence of a dielectric medium. We introduce a definition of the lateral resolution based on the force due to a test particle being either a point charge or a polarizable particle on the dielectric surface. The behaviour has been studied over a wide range of typical experimental parameters: tip-sample distance (1-20) nm, sample thickness (0-5) μm and dielectric constant (1-20), using the numerical simulation of the equivalent charge method. For potential heterogeneities on metallic surfaces expressions are in agreement with the bibliography. The lateral resolution of samples having a dielectric constant of more than 10 tends to metallic behaviour. We found a characteristic thickness of 100 nm, above which the lateral resolution measured on the dielectric surface is close to that of an infinite medium. As previously reported, the lateral resolution is better in the gradient mode than in the force mode. Finally, we showed that for the same experimental conditions, the lateral resolution is better for a polarizable particle than for a charge, i.e. dielectric heterogeneities should always look 'sharper' (better resolved) than inhomogeneous charge distributions. This fact should be taken into account when interpreting images of heterogeneous samples.

  10. Numerical study of the lateral resolution in electrostatic force microscopy for dielectric samples

    Energy Technology Data Exchange (ETDEWEB)

    Riedel, C; AlegrIa, A; Colmenero, J [Departamento de Fisica de Materiales UPV/EHU, Facultad de Quimica, Apartado 1072, 20080 San Sebastian (Spain); Schwartz, G A [Centro de Fisica de Materiales CSIC-UPV/EHU, Paseo Manuel de Lardizabal 5, 20018 San Sebastian (Spain); Saenz, J J, E-mail: riedel@ies.univ-montp2.fr [Donostia International Physics Center, Paseo Manuel de Lardizabal 4, 20018 San Sebastian (Spain)

    2011-07-15

    We present a study of the lateral resolution in electrostatic force microscopy for dielectric samples in both force and gradient modes. Whereas previous studies have reported expressions for metallic surfaces having potential heterogeneities (Kelvin probe force microscopy), in this work we take into account the presence of a dielectric medium. We introduce a definition of the lateral resolution based on the force due to a test particle being either a point charge or a polarizable particle on the dielectric surface. The behaviour has been studied over a wide range of typical experimental parameters: tip-sample distance (1-20) nm, sample thickness (0-5) {mu}m and dielectric constant (1-20), using the numerical simulation of the equivalent charge method. For potential heterogeneities on metallic surfaces expressions are in agreement with the bibliography. The lateral resolution of samples having a dielectric constant of more than 10 tends to metallic behaviour. We found a characteristic thickness of 100 nm, above which the lateral resolution measured on the dielectric surface is close to that of an infinite medium. As previously reported, the lateral resolution is better in the gradient mode than in the force mode. Finally, we showed that for the same experimental conditions, the lateral resolution is better for a polarizable particle than for a charge, i.e. dielectric heterogeneities should always look 'sharper' (better resolved) than inhomogeneous charge distributions. This fact should be taken into account when interpreting images of heterogeneous samples.

  11. Handgrip force steadiness in young and older adults: a reproducibility study.

    Science.gov (United States)

    Blomkvist, Andreas W; Eika, Fredrik; de Bruin, Eling D; Andersen, Stig; Jorgensen, Martin

    2018-04-02

    Force steadiness is a quantitative measure of the ability to control muscle tonus. It is an independent predictor of functional performance and has shown to correlate well with different degrees of motor impairment following stroke. Despite being clinically relevant, few studies have assessed the validity of measuring force steadiness. The aim of this study was to explore the reproducibility of handgrip force steadiness, and to assess age difference in steadiness. Intrarater reproducibility (the degree to which a rating gives consistent result on separate occasions) was investigated in a test-retest design with seven days between sessions. Ten young and thirty older adults were recruited and handgrip steadiness was tested at 5%, 10% and 25% of maximum voluntary contraction (MVC) using Nintendo Wii Balance Board (WBB). Coefficients of variation were calculated from the mean force produced (CVM) and the target force (CVT). Area between the force curve and the target force line (Area) was also calculated. For the older adults we explored reliability using intraclass correlation coefficient (ICC) and agreement using standard error of measurement (SEM), limits of agreement (LOA) and smallest real difference (SRD). A systematic improvement in handgrip steadiness was found between sessions for all measures (CVM, CVT, Area). CVM and CVT at 5% of MVC showed good to high reliability, while Area had poor reliability for all percentages of MVC. Averaged ICC for CVM, CVT and Area was 0.815, 0.806 and 0.464, respectively. Averaged ICC on 5%, 10%, and 25% of MVC was 0.751, 0.667 and 0.668, respectively. Measures of agreement showed similar trends with better results for CVM and CVT than for Area. Young adults had better handgrip steadiness than older adults across all measures. The CVM and CVT measures demonstrated good reproducibility at lower percentages of MVC using the WBB, and could become relevant measures in the clinical setting. The Area measure had poor reproducibility

  12. Magnetic force microscopy and simulation studies on Co 50 Fe 50 ...

    Indian Academy of Sciences (India)

    We studied the magnetization reversal mechanism of single-layered Co50Fe50 nanomagnets by measuring the magnetization reversal and using the micromagnetic simulations. The magnetization reversal strongly depends on the thickness of the nanomagnets. In the remanent state, the magnetic force microscopy studies ...

  13. The Australian Defence Force Mental Health Prevalence and Wellbeing Study: design and methods.

    NARCIS (Netherlands)

    Hooff, M.V.; McFarlane, A.C.; Davies, C.E.; Searle, A.K.; Fairweather-Schmidt, A.K.; Verhagen, A.F.; Benassi, H.; Hodson, S.E.

    2014-01-01

    BACKGROUND: The Australian Defence Force (ADF) Mental Health Prevalence and Wellbeing Study (MHPWS) is the first study of mental disorder prevalence in an entire military population. OBJECTIVE: The MHPWS aims to establish mental disorder prevalence, refine current ADF mental health screening

  14. Study on 16O in the alpha particle model using three-body forces

    International Nuclear Information System (INIS)

    Agrello, D.A.

    1979-01-01

    A study of the ground state of 16 O is made using an alpha particle model, all without internal structure, interacting through two-and three-body forces. Some nuclear properties of 16 O, such as binding energy and gaps, are also studied. (L.C.) [pt

  15. Accuracy and precision of protein-ligand interaction kinetics determined from chemical shift titrations

    Energy Technology Data Exchange (ETDEWEB)

    Markin, Craig J.; Spyracopoulos, Leo, E-mail: leo.spyracopoulos@ualberta.ca [University of Alberta, Department of Biochemistry (Canada)

    2012-12-15

    NMR-monitored chemical shift titrations for the study of weak protein-ligand interactions represent a rich source of information regarding thermodynamic parameters such as dissociation constants (K{sub D}) in the micro- to millimolar range, populations for the free and ligand-bound states, and the kinetics of interconversion between states, which are typically within the fast exchange regime on the NMR timescale. We recently developed two chemical shift titration methods wherein co-variation of the total protein and ligand concentrations gives increased precision for the K{sub D} value of a 1:1 protein-ligand interaction (Markin and Spyracopoulos in J Biomol NMR 53: 125-138, 2012). In this study, we demonstrate that classical line shape analysis applied to a single set of {sup 1}H-{sup 15}N 2D HSQC NMR spectra acquired using precise protein-ligand chemical shift titration methods we developed, produces accurate and precise kinetic parameters such as the off-rate (k{sub off}). For experimentally determined kinetics in the fast exchange regime on the NMR timescale, k{sub off} {approx} 3,000 s{sup -1} in this work, the accuracy of classical line shape analysis was determined to be better than 5 % by conducting quantum mechanical NMR simulations of the chemical shift titration methods with the magnetic resonance toolkit GAMMA. Using Monte Carlo simulations, the experimental precision for k{sub off} from line shape analysis of NMR spectra was determined to be 13 %, in agreement with the theoretical precision of 12 % from line shape analysis of the GAMMA simulations in the presence of noise and protein concentration errors. In addition, GAMMA simulations were employed to demonstrate that line shape analysis has the potential to provide reasonably accurate and precise k{sub off} values over a wide range, from 100 to 15,000 s{sup -1}. The validity of line shape analysis for k{sub off} values approaching intermediate exchange ({approx}100 s{sup -1}), may be facilitated by

  16. Accuracy and precision of protein–ligand interaction kinetics determined from chemical shift titrations

    International Nuclear Information System (INIS)

    Markin, Craig J.; Spyracopoulos, Leo

    2012-01-01

    NMR-monitored chemical shift titrations for the study of weak protein–ligand interactions represent a rich source of information regarding thermodynamic parameters such as dissociation constants (K D ) in the micro- to millimolar range, populations for the free and ligand-bound states, and the kinetics of interconversion between states, which are typically within the fast exchange regime on the NMR timescale. We recently developed two chemical shift titration methods wherein co-variation of the total protein and ligand concentrations gives increased precision for the K D value of a 1:1 protein–ligand interaction (Markin and Spyracopoulos in J Biomol NMR 53: 125–138, 2012). In this study, we demonstrate that classical line shape analysis applied to a single set of 1 H– 15 N 2D HSQC NMR spectra acquired using precise protein–ligand chemical shift titration methods we developed, produces accurate and precise kinetic parameters such as the off-rate (k off ). For experimentally determined kinetics in the fast exchange regime on the NMR timescale, k off ∼ 3,000 s −1 in this work, the accuracy of classical line shape analysis was determined to be better than 5 % by conducting quantum mechanical NMR simulations of the chemical shift titration methods with the magnetic resonance toolkit GAMMA. Using Monte Carlo simulations, the experimental precision for k off from line shape analysis of NMR spectra was determined to be 13 %, in agreement with the theoretical precision of 12 % from line shape analysis of the GAMMA simulations in the presence of noise and protein concentration errors. In addition, GAMMA simulations were employed to demonstrate that line shape analysis has the potential to provide reasonably accurate and precise k off values over a wide range, from 100 to 15,000 s −1 . The validity of line shape analysis for k off values approaching intermediate exchange (∼100 s −1 ), may be facilitated by more accurate K D measurements from NMR

  17. Accuracy and precision of protein-ligand interaction kinetics determined from chemical shift titrations.

    Science.gov (United States)

    Markin, Craig J; Spyracopoulos, Leo

    2012-12-01

    NMR-monitored chemical shift titrations for the study of weak protein-ligand interactions represent a rich source of information regarding thermodynamic parameters such as dissociation constants (K ( D )) in the micro- to millimolar range, populations for the free and ligand-bound states, and the kinetics of interconversion between states, which are typically within the fast exchange regime on the NMR timescale. We recently developed two chemical shift titration methods wherein co-variation of the total protein and ligand concentrations gives increased precision for the K ( D ) value of a 1:1 protein-ligand interaction (Markin and Spyracopoulos in J Biomol NMR 53: 125-138, 2012). In this study, we demonstrate that classical line shape analysis applied to a single set of (1)H-(15)N 2D HSQC NMR spectra acquired using precise protein-ligand chemical shift titration methods we developed, produces accurate and precise kinetic parameters such as the off-rate (k ( off )). For experimentally determined kinetics in the fast exchange regime on the NMR timescale, k ( off ) ~ 3,000 s(-1) in this work, the accuracy of classical line shape analysis was determined to be better than 5 % by conducting quantum mechanical NMR simulations of the chemical shift titration methods with the magnetic resonance toolkit GAMMA. Using Monte Carlo simulations, the experimental precision for k ( off ) from line shape analysis of NMR spectra was determined to be 13 %, in agreement with the theoretical precision of 12 % from line shape analysis of the GAMMA simulations in the presence of noise and protein concentration errors. In addition, GAMMA simulations were employed to demonstrate that line shape analysis has the potential to provide reasonably accurate and precise k ( off ) values over a wide range, from 100 to 15,000 s(-1). The validity of line shape analysis for k ( off ) values approaching intermediate exchange (~100 s(-1)), may be facilitated by more accurate K ( D ) measurements

  18. The vibrational source strength descriptor using power input from equivalent forces: a simulation study

    DEFF Research Database (Denmark)

    Laugesen, Søren; Ohlrich, Mogens

    1994-01-01

    Simple, yet reliable methods for the approximate determination of the vibratory power supplied by the internal excitation forces of a given vibrational source are of great interest. One such method that relies on the application of a number of “equivalent forces” and measurements of the mean...... squared velocity on either the source or the receiving structure is studied in this paper by means of computer simulations. The study considers a simple system of two flexural beams coupled via a pair of springs. The investigation shows that a relatively small number of equivalent forces suffice...

  19. Isothermal titration calorimetry and surface plasmon resonance allow quantifying substrate binding to different binding sites of Bacillus subtilis xylanase

    DEFF Research Database (Denmark)

    Cuyvers, Sven; Dornez, Emmie; Abou Hachem, Maher

    2012-01-01

    Isothermal titration calorimetry and surface plasmon resonance were tested for their ability to study substrate binding to the active site (AS) and to the secondary binding site (SBS) of Bacillus subtilis xylanase A separately. To this end, three enzyme variants were compared. The first...

  20. Reference test methods for total water in lint cotton by Karl Fischer Titration and low temperature distillation

    Science.gov (United States)

    In a study of comparability of total water contents (%) of conditioned cottons by Karl Fischer Titration (KFT) and Low Temperature Distillation (LTD) reference methods, we demonstrated a match of averaged results based on a large number of replications and weighing the test specimens at the same tim...

  1. Detoxification with titration and tapering in gamma-hydroxybutyrate (GHB) dependent patients : The Dutch GHB monitor project

    NARCIS (Netherlands)

    Dijkstra, Boukje A G; Kamal, Rama; van Noorden, Martijn S; de Haan, Hein; Loonen, Anton J.M.; De Jong, Cor A J

    2016-01-01

    BACKGROUND AND AIMS: Gamma-hydroxybutyrate (GHB) detoxification procedures have been insufficiently studied for effectiveness and safety. Based on case reports, benzodiazepines are generally regarded as first-choice agents in GHB detoxification. Detoxification by titration and tapering (DeTiTap)

  2. Exploring variation in binding of Protein A and Protein G to immunoglobulin type G by isothermal titration calorimetry

    DEFF Research Database (Denmark)

    Lund, L. N.; Christensen, T.; Toone, E.

    2011-01-01

    ligands and for the establishment of generic processes for the purification of various antibodies. In this paper, the interactions between the two IgG-binding proteins and IgG of two different subclasses, IgG1 and IgG4, as well as their analogous Fc fragments have been studied by isothermal titration...

  3. New implementation of a shear-force microscope suitable to study topographical features over wide areas

    International Nuclear Information System (INIS)

    Ustione, A.; Cricenti, A.; Piacentini, M.; Felici, A. C.

    2006-01-01

    A new implementation of a shear-force microscope is described that uses a shear-force detection system to perform topographical imaging of large areas (∼1x1 mm 2 ). This implementation finds very interesting application in the study of archeological or artistic samples. Three dc motors are used to move a sample during a scan, allowing the probe tip to follow the surface and to face height differences of several tens of micrometers. This large-area topographical imaging mode exploits new subroutines that were added to the existing homemade software; these subroutines were created in Microsoft VISUAL BASIC 6.0 programming language. With this new feature our shear-force microscope can be used to study topographical details over large areas of archaeological samples in a nondestructive way. We show results detecting worn reliefs over a coin

  4. Numerical studies on the force characteristic of superconducting linear synchronous motor with HTS bulk magnet

    Science.gov (United States)

    Tang, Junjie; Li, Jing; Li, Xiang; Han, Le

    2018-03-01

    High temperature superconductor (HTS) bulks have significant potential use in linear motor application act as quasi-permanent magnet to replace traditional magnets. Force characteristic between HTS bulk magnet and traveling magnetic field was investigated with numerical simulation and experimental measurement in this paper. Influences of bulk height and number on the force characteristic were studied by the finite element model considering the nonlinear E-J relationship. Study was also made on addition of a back iron plate to the bulk magnet. Besides, force characteristic of bulk was compared with the permanent magnet results. The small initial decrease of the thrust could be explained by inside superconducting current redistribution. It was found that efficiency of linear motor did not increase by adding more bulk magnets. The bulk magnet will be remagnetized instead of erasing trapped field with the increase of the traveling magnetic field strength. The conclusions are helpful in prediction and design the linear motor with HTS bulk magnet.

  5. Axitinib with or without dose titration for first-line metastatic renal-cell carcinoma: a randomised double-blind phase 2 trial.

    Science.gov (United States)

    Rini, Brian I; Melichar, Bohuslav; Ueda, Takeshi; Grünwald, Viktor; Fishman, Mayer N; Arranz, José A; Bair, Angel H; Pithavala, Yazdi K; Andrews, Glen I; Pavlov, Dmitri; Kim, Sinil; Jonasch, Eric

    2013-11-01

    Population pharmacokinetic data suggest axitinib plasma exposure correlates with efficacy in metastatic renal-cell carcinoma. Axitinib dose titration might optimise exposure and improve outcomes. We prospectively assessed the efficacy and safety of axitinib dose titration in previously untreated patients with metastatic renal-cell carcinoma. In this randomised, double-blind, multicentre, phase 2 study, patients were enrolled from 49 hospitals and outpatient clinics in the Czech Republic, Germany, Japan, Russia, Spain, and USA. Patients with treatment-naive metastatic renal-cell carcinoma received axitinib 5 mg twice daily during a 4 week lead-in period. Those patients with blood pressure 150/90 mm Hg or lower, no grade 3 or 4 treatment-related toxic effects, no dose reductions, and no more than two antihypertensive drugs for 2 consecutive weeks were stratified by Eastern Cooperative Oncology Group performance status (0 vs 1), and then randomly assigned (1:1) to either masked titration with axitinib to total twice daily doses of 7 mg, and then 10 mg, if tolerated, or placebo titration. Patients who did not meet these criteria continued without titration. The primary objective was comparison of the proportion of patients achieving an objective response between randomised groups. Safety analyses were based on all patients who received at least one dose of axitinib. Between Sept 2, 2009, and Feb 28, 2011, we enrolled 213 patients, of whom 112 were randomly assigned to either the axitinib titration group (56 patients) or the placebo titration group (56 patients). 91 were not eligible for titration, and ten withdrew during the lead-in period. 30 patients (54%, 95% CI 40-67) in the axitinib titration group had an objective response, as did 19 patients (34%, 22-48]) in the placebo titration group (one-sided p=0·019). 54 (59%, 95% CI 49-70) of non-randomised patients achieved an objective response. Common grade 3 or worse, all-causality adverse events in treated patients

  6. Axitinib with or without dose titration for first-line metastatic renal-cell carcinoma: a randomised double-blind phase 2 trial

    Science.gov (United States)

    Rini, Brian I; Melichar, Bohuslav; Ueda, Takeshi; GrÜnwald, Viktor; Fishman, Mayer N; Arranz, José A; Bair, Angel H; Pithavala, Yazdi K; Andrews, Glen I; Pavlov, Dmitri; Kim, Sinil; Jonasch, Eric

    2014-01-01

    Summary Background Population pharmacokinetic data suggest axitinib plasma exposure correlates with efficacy in metastatic renal-cell carcinoma. Axitinib dose titration might optimise exposure and improve outcomes. We prospectively assessed the efficacy and safety of axitinib dose titration in previously untreated patients with metastatic renal-cell carcinoma. Methods In this randomised, double-blind, multicentre, phase 2 study, patients were enrolled from 49 hospitals and outpatient clinics in the Czech Republic, Germany, Japan, Russia, Spain, and USA. Patients with treatment-naive metastatic renal-cell carcinoma received axitinib 5 mg twice daily during a 4 week lead-in period. Those patients with blood pressure 150/90 mm Hg or lower, no grade 3 or 4 treatment-related toxic effects, no dose reductions, and no more than two antihypertensive drugs for 2 consecutive weeks were stratified by Eastern Cooperative Oncology Group performance status (0 vs 1), and then randomly assigned (1:1) to either masked titration with axitinib to total twice daily doses of 7 mg, and then 10 mg, if tolerated, or placebo titration. Patients who did not meet these criteria continued without titration. The primary objective was comparison of the proportion of patients achieving an objective response between randomised groups. Safety analyses were based on all patients who received at least one dose of axitinib. This ongoing trial is registered with ClinicalTrials.gov, number NCT00835978. Findings Between Sept 2, 2009, and Feb 28, 2011, we enrolled 213 patients, of whom 112 were randomly assigned to either the axitinib titration group (56 patients) or the placebo titration group (56 patients). 91 were not eligible for titration, and ten withdrew during the lead-in period. 30 patients (54%, 95% CI 40–67) in the axitinib titration group had an objective response, as did 19 patients (34%, 22–48]) in the placebo titration group (one-sided p=0·019). 54 (59%, 95% CI 49–70) of non

  7. Acidity titration curves - a versatile tool for the characterisation of acidic mine waste water

    International Nuclear Information System (INIS)

    Fyson, A.

    2000-01-01

    Acidity titrations with NaOH are valuable tools for characterisation of acidic mine waters. - Titrations can be used to estimate metal concentrations. - Titrations can be carried out in the field, minimising changes in water chemistry due to sample handling time and procedure. (orig.)

  8. Colloid Titration--A Rapid Method for the Determination of Charged Colloid.

    Science.gov (United States)

    Ueno, Keihei; Kina, Ken'yu

    1985-01-01

    "Colloid titration" is a volumetric method for determining charged polyelectrolytes in aqueous solutions. The principle of colloid titration, reagents used in the procedure, methods of endpoint detection, preparation of reagent solutions, general procedure used, results obtained, and pH profile of colloid titration are considered. (JN)

  9. The Acid-Base Titration of a Very Weak Acid: Boric Acid

    Science.gov (United States)

    Celeste, M.; Azevedo, C.; Cavaleiro, Ana M. V.

    2012-01-01

    A laboratory experiment based on the titration of boric acid with strong base in the presence of d-mannitol is described. Boric acid is a very weak acid and direct titration with NaOH is not possible. An auxiliary reagent that contributes to the release of protons in a known stoichiometry facilitates the acid-base titration. Students obtain the…

  10. Thermometric titration of cadmium with sodium diethyldithiocarbamate, with oxidation by hydrogen peroxide as indicator reaction.

    Science.gov (United States)

    Hattori, T; Yoshida, H

    1987-08-01

    A new method of end-point indication is described for thermometric titration of cadmium with sodium diethyldithiocarbamate (DDTC). It is based on the redox reaction between hydrogen peroxide added to the system before titration, and the first excess of DDTC. Amounts of cadmium in the range 10-50 mumoles are titrated within 1% error.

  11. Clinical predictors of central sleep apnea evoked by positive airway pressure titration

    Directory of Open Access Journals (Sweden)

    Moro M

    2016-07-01

    Full Text Available Marilyn Moro,1 Karen Gannon,1 Kathy Lovell,1 Margaret Merlino,1 James Mojica,2 Matt T Bianchi,1,3 1Neurology Department, 2Pulmonary and Critical Care Medicine, Massachusetts General Hospital, Boston, MA, USA; 3Division of Sleep Medicine, Harvard Medical School, Boston, MA, USA Purpose: Treatment-emergent central sleep apnea (TECSA, also called complex apnea, occurs in 5%–15% of sleep apnea patients during positive airway pressure (PAP therapy, but the clinical predictors are not well understood. The goal of this study was to explore possible predictors in a clinical sleep laboratory cohort, which may highlight those at risk during clinical management.Methods: We retrospectively analyzed 728 patients who underwent PAP titration (n=422 split night; n=306 two-night. Demographics and self-reported medical comorbidities, medications, and behaviors as well as standard physiological parameters from the polysomnography (PSG data were analyzed. We used regression analysis to assess predictors of binary presence or absence of central apnea index (CAI ≥5 during split PSG (SN-PSG versus full-night PSG (FN-PSG titrations.Results: CAI ≥5 was present in 24.2% of SN-PSG and 11.4% of FN-PSG patients during titration. Male sex, maximum continuous positive airway pressure, and use of bilevel positive airway pressure were predictors of TECSA, and rapid eye movement dominance was a negative predictor, for both SN-PSG and FN-PSG patients. Self-reported narcotics were a positive predictor of TECSA, and the time spent in stage N2 sleep was a negative predictor only for SN-PSG patients. Self-reported history of stroke and the CAI during the diagnostic recording predicted TECSA only for FN-PSG patients.Conclusion: Clinical predictors of treatment-evoked central apnea spanned demographic, medical history, sleep physiology, and titration factors. Improved predictive models may be increasingly important as diagnostic and therapeutic modalities move away from the

  12. A feasibility study for experimentally determining dynamic force distribution in a lap joint

    Energy Technology Data Exchange (ETDEWEB)

    Mayes, Randall Lee [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2013-11-01

    Developing constitutive models of the physics in mechanical joints is currently stymied by inability to measure forces and displacements within the joint. The current state of the art estimates whole joint stiffness and energy loss per cycle from external measured force input and one or two acceleration responses. To validate constitutive models beyond this state requires a measurement of the distributed forces and displacements at the joint interface. Unfortunately, introducing measurement devices at the interface completely disrupts the desired physics. A feasibility study is presented for a non-intrusive method of solving for the interface dynamic forces from an inverse problem using full field measured responses. The responses come from the viewable surface of a beam. The noise levels associated with digital image correlation and continuous scanning laser Doppler velocimetry are evaluated from typical beam experiments. Two inverse problems are simulated. One utilizes the extended Sum of Weighted Accelerations Technique (SWAT). The second is a new approach dubbed the method of truncated orthogonal forces. These methods are much more robust if the contact patch geometry is well identified. Various approaches to identifying the contact patch are investigated, including ion marker tracking, Prussian blue and ultrasonic measurements. A typical experiment is conceived for a beam which has a lap joint at one end with a single bolt connecting it to another identical beam. In a virtual test using the beam finite element analysis, it appears that the SWAT inverse method requires evaluation of too many coefficients to adequately identify the force distribution to be viable. However, the method of truncated orthogonal forces appears viable with current digital image correlation (and probably other) imaging techniques.

  13. Effects of positive end-expiratory pressure titration and recruitment maneuver on lung inflammation and hyperinflation in experimental acid aspiration-induced lung injury.

    Science.gov (United States)

    Ambrosio, Aline M; Luo, Rubin; Fantoni, Denise T; Gutierres, Claudia; Lu, Qin; Gu, Wen-Jie; Otsuki, Denise A; Malbouisson, Luiz M S; Auler, Jose O C; Rouby, Jean-Jacques

    2012-12-01

    In acute lung injury positive end-expiratory pressure (PEEP) and recruitment maneuver are proposed to optimize arterial oxygenation. The aim of the study was to evaluate the impact of such a strategy on lung histological inflammation and hyperinflation in pigs with acid aspiration-induced lung injury. Forty-seven pigs were randomly allocated in seven groups: (1) controls spontaneously breathing; (2) without lung injury, PEEP 5 cm H2O; (3) without lung injury, PEEP titration; (4) without lung injury, PEEP titration + recruitment maneuver; (5) with lung injury, PEEP 5 cm H2O; (6) with lung injury, PEEP titration; and (7) with lung injury, PEEP titration + recruitment maneuver. Acute lung injury was induced by intratracheal instillation of hydrochloric acid. PEEP titration was performed by incremental and decremental PEEP from 5 to 20 cm H2O for optimizing arterial oxygenation. Three recruitment maneuvers (pressure of 40 cm H2O maintained for 20 s) were applied to the assigned groups at each PEEP level. Proportion of lung inflammation, hemorrhage, edema, and alveolar wall disruption were recorded on each histological field. Mean alveolar area was measured in the aerated lung regions. Acid aspiration increased mean alveolar area and produced alveolar wall disruption, lung edema, alveolar hemorrhage, and lung inflammation. PEEP titration significantly improved arterial oxygenation but simultaneously increased lung inflammation in juxta-diaphragmatic lung regions. Recruitment maneuver during PEEP titration did not induce additional increase in lung inflammation and alveolar hyperinflation. In a porcine model of acid aspiration-induced lung injury, PEEP titration aimed at optimizing arterial oxygenation, substantially increased lung inflammation. Recruitment maneuvers further improved arterial oxygenation without additional effects on inflammation and hyperinflation.

  14. Monsoonal Responses to External Forcings over the Past Millennium: A Model Study (Invited)

    Science.gov (United States)

    Liu, J.; Wang, B.

    2009-12-01

    understanding the latitudinal differences of the monsoonal responses to external forcings and internal feedback processes. The strength of the forced response depends on latitude. On centennial-millennial time scales, the variation of the extratropical and subtropical rainfall tends to follow the effective solar radiation forcing closely; the tropical rainfall is less sensitive to the effective solar radiation forcing but responds significantly to the modern anthropogenic CO2 forcing. The spatial patterns and structures of the forced response differ from the internal mode (i.e., interannual variability that arises primarily from the internal feedback processes within the climate system). Further, the behavior of the internal mode is effectively modulated by changes in the mean state on the centennial to millennial time scales. These findings have important ramification in understanding the differences and linkages between the forced and internal modes of variability as well as in promoting communication between scientists studying modern- and paleo-monsoon variations.

  15. Labor force participation in later life: evidence from a cross-sectional study in Thailand.

    Science.gov (United States)

    Adhikari, Ramesh; Soonthorndhada, Kusol; Haseen, Fariha

    2011-04-08

    The labor force participation rate is an important indicator of the state of the labor market and a major input into the economy's potential for creating goods and services. The objectives of this paper are to examine the prevalence of labor force participation among older people in Thailand and to investigate the factors affecting this participation. The data for this study were drawn from the '2007 Survey of Older Persons' in Thailand. Bivariate analysis was used to identify the factors associated with labor force participation. The variables were further examined using multivariate analysis in order to identify the significant predictors of the likelihood of older people participating in the labor force, after controlling for other variables. Overall, 30,427 elderly people aged 60 or above were interviewed. More than a third (35%) of all respondents had participated in the labor force during the seven days preceding the survey. Respondents who were female (OR=0.56), those who were older (OR=0.47 for 70-79 and 0.21 for 80+ years), those who were widowed/divorced (OR=0.85), those who were living with their children (OR=0.69), those whose family income was relatively low, and those who worked in government sectors (OR=0.33) were less likely to participate in the labor force than were their counterparts. On the other hand, those who lived in urban areas (OR=1.2), those who had a low level of education (OR, secondary level 1.8, primary 2.4, and no schooling 2.5), those who were the head of the household (OR=1.9), and those who were in debt (OR=2.3) were more likely be involved in the labor force than their comparison groups. Furthermore, respondents who experienced greater difficulty in daily living, those who suffered from more chronic diseases, and those who assessed their health as poor were less likely to participate in the labor force than their counterparts. Labor force participation in their advanced years is not uncommon among the Thai elderly. The results

  16. Labor force participation in later life: Evidence from a cross-sectional study in Thailand

    Directory of Open Access Journals (Sweden)

    Soonthorndhada Kusol

    2011-04-01

    Full Text Available Abstract Background The labor force participation rate is an important indicator of the state of the labor market and a major input into the economy's potential for creating goods and services. The objectives of this paper are to examine the prevalence of labor force participation among older people in Thailand and to investigate the factors affecting this participation. Methods The data for this study were drawn from the '2007 Survey of Older Persons' in Thailand. Bivariate analysis was used to identify the factors associated with labor force participation. The variables were further examined using multivariate analysis in order to identify the significant predictors of the likelihood of older people participating in the labor force, after controlling for other variables. Results Overall, 30,427 elderly people aged 60 or above were interviewed. More than a third (35% of all respondents had participated in the labor force during the seven days preceding the survey. Respondents who were female (OR = 0.56, those who were older (OR = 0.47 for 70-79 and 0.21 for 80+ years, those who were widowed/divorced (OR = 0.85, those who were living with their children (OR = 0.69, those whose family income was relatively low, and those who worked in government sectors (OR = 0.33 were less likely to participate in the labor force than were their counterparts. On the other hand, those who lived in urban areas (OR = 1.2, those who had a low level of education (OR, secondary level 1.8, primary 2.4, and no schooling 2.5, those who were the head of the household (OR = 1.9, and those who were in debt (OR = 2.3 were more likely be involved in the labor force than their comparison groups. Furthermore, respondents who experienced greater difficulty in daily living, those who suffered from more chronic diseases, and those who assessed their health as poor were less likely to participate in the labor force than their counterparts. Conclusion Labor force participation in

  17. Solução oral escalonada de misoprostol para indução do parto: estudo piloto Titrated oral solution of misoprostol for labour induction: a pilot study

    Directory of Open Access Journals (Sweden)

    Alex Sandro Rolland Souza

    2010-05-01

    Full Text Available OBJETIVO: avaliar a efetividade e a segurança da administração de uma nova formulação de misoprostol em solução por via oral, com doses escalonadas, para indução do parto de feto vivo a termo. MÉTODOS: realizou-se um estudo multicêntrico, do tipo ensaio clínico, aberto, não-randomizado, no período de Julho a Dezembro de 2008. Foram incluídas 30 pacientes com indicação de indução do trabalho de parto, a termo, com feto vivo, índice de Bishop 5. Foram excluídas mulheres com cicatriz uterina, cardiotocografia alterada, gestação múltipla, restrição de crescimento fetal, hemorragia genital e presença de tumores, ulcerações ou malformações genitais. A dose inicial da solução oral foi de 20µg/h de misoprostol, nas primeiras 6 horas, aumentando em 20µg/h de misoprostol a cada 6 horas, se o trabalho de parto não fosse deflagrado, até uma dose máxima de 80µg/h, nas primeiras 24 horas, mantendo a dose máxima (80µg/h por mais 24 horas, se necessário. RESULTADOS: o trabalho de parto foi induzido satisfatoriamente em 96,7% das gestantes. O intervalo entre a primeira dose e o início das contrações uterinas foi de 3,8±1,8 horas, enquanto o intervalo entre a dose inicial e o parto variou entre 6 e 24 horas. A frequência de parto vaginal foi de 80% (n=24. A maioria das gestantes iniciou o trabalho de parto com a dose de 20µg/h (60%; n=18. A taquissistolia ocorreu em 13,3% das gestações e líquido meconial foi detectado em 20% dos casos. Houve dois casos de escore de Apgar PURPOSE: to test effectiveness and safety of the oral administration of a new misoprostol formulation in titrated doses for the induction of delivery of a live fetus at term. METHODS: an open pilot multicenter, non-randomized clinical trial was conducted from July to December 2008. A total of 30 patients with indications for induction of labor were included. The patients had a live fetus, Bishop score 5. Exclusion criteria were previous uterine

  18. A quantitative mechanistic description of Ni, Zn and Ca sorption on Na-Montmorillonite. Part I: Physico-chemical characterisation and titration measurements

    International Nuclear Information System (INIS)

    Baeyens, B.; Bradbury, M.H.

    1995-07-01

    The work presented in this report is primarily concerned with characterisation studies and titration measurements on conditioned Na-montmorillonite. The starting material, SWy-1 Na-montmorillonite (Crook County, Wyoming, USA), contains background metal impurities, soluble salts and sparingly soluble minerals which can influence titration and sorption measurements and thereby lead to difficulties in the interpretation of the data. A conditioning procedure is described which yielded a purified clay material in the homoionic sodium form with a particle size 4 . The reasons for choosing a batch method, coupled with back titration of the supernatant solutions, instead of a continuous procedure, are fully discussed. Chemical analyses data for the supernatant solutions are presented in detail. The influence of background impurities, not removed by the conditioning, and cation exchange processes on the form of the titration curves were investigates. Net Na-montmorillonite titration curves at two different ionic strengths were derived which are considered to reflect only the acid/base behaviour of ≡SOH type surface sites. The acid end point in the titration data was used to estimate an ≡SOH site capacity of 0.08 moles per kg conditioned Na-montmorillonite. (author) 8 figs., 19 tabs., refs

  19. Boehm Titration Revisited (Part I: Practical Aspects for Achieving a High Precision in Quantifying Oxygen-Containing Surface Groups on Carbon Materials

    Directory of Open Access Journals (Sweden)

    Jan Schönherr

    2018-04-01

    Full Text Available Practical aspects of the Boehm titration method are evaluated for obtaining reliable results in the quantification of oxygen-containing surface groups in a short time. Analytical criteria such as accuracy, repeatability, precision, and robustness are applied. Oxidized multi-walled carbon nanotubes (MWCNTs are used as the model substance. Different reaction bases (NaHCO3(aq, Na2CO3(aq, NaOH(aq are applied and treatment times are studied. We also show that smaller amounts of carbon material can be reliably analyzed by using an autotitrator combined with a pH electrode. We find that indirect titration with Na2CO3 results in the highest titration precision and accuracy despite the lower base strength compared with NaOH. Therefore, CO2 impurities do not have to be removed and only 7 min is necessary for one titration. The titration error with respect to the proposed method is 0.15% of the aliquot volume. The mixing method during the carbon treatment with bases (stirring, shaking, ultrasound treatment has no influence on the result as long as one allows a few hours for the reaction to complete. Finally, we provide a standard operating procedure for obtaining results with high precision during Boehm titration.

  20. A resolution study for electrostatic force microscopy on bimetallic samples using the boundary element method

    International Nuclear Information System (INIS)

    Shen Yongxing; Lee, Minhwan; Lee, Wonyoung; Barnett, David M; Pinsky, Peter M; Prinz, Friedrich B

    2008-01-01

    Electrostatic force microscopy (EFM) is a special design of non-contact atomic force microscopy used for detecting electrostatic interactions between the probe tip and the sample. Its resolution is limited by the finite probe size and the long-range characteristics of electrostatic forces. Therefore, quantitative analysis is crucial to understanding the relationship between the actual local surface potential distribution and the quantities obtained from EFM measurements. To study EFM measurements on bimetallic samples with surface potential inhomogeneities as a special case, we have simulated such measurements using the boundary element method and calculated the force component and force gradient component that would be measured by amplitude modulation (AM) EFM and frequency modulation (FM) EFM, respectively. Such analyses have been performed for inhomogeneities of various shapes and sizes, for different tip-sample separations and tip geometries, for different applied voltages, and for different media (e.g., vacuum or water) in which the experiment is performed. For a sample with a surface potential discontinuity, the FM-EFM resolution expression agrees with the literature; however, the simulation for AM-EFM suggests the existence of an optimal tip radius of curvature in terms of resolution. On the other hand, for samples with strip- and disk-shaped surface potential inhomogeneities, we have obtained quantitative expressions for the detectability size requirements as a function of experimental conditions for both AM- and FM-EFMs, which suggest that a larger tip radius of curvature is moderately favored for detecting the presence of such inhomogeneities

  1. Binding activity of patterned concanavalin A studied by atomic force microscopy

    International Nuclear Information System (INIS)

    Lebed, Kateryna; Pyka-Fosciak, Grazyna; Raczkowska, Joanna; Lekka, Malgorzata; Styczen, Jan

    2005-01-01

    The mode of protein immobilization plays a crucial role in the preparation of protein microarrays used for a wide spectrum of applications in analytical biochemistry. The microcontact printing technique was used to form a protein pattern using concanavalin A (Con A) since Con A belongs to a group of proteins widely used in analytical assays due to their selectivity as regards different kinds of carbohydrates. Atomic force microscopy was used to image surface topography, delivering information about the quality of the protein pattern. The force spectroscopy mode was used to verify the functional activity of deposited proteins via determination of the forces of interaction between Con A and carboxypeptidase Y bearing carbohydrate structure recognized by Con A. The calculated binding force between Con A and CaY was 105 ± 2 pN and it was compared with that measured for Con A deposited directly from the protein solution. The similarity of the value obtained for the interaction force was independent of the mode of protein deposition, thereby verifying that the microcontact printing technique did not influence the carbohydrate binding activity of Con A. The correlation between the surface topography of patterned samples and adhesion maps obtained showed the possible use of AFM for studying the chemical properties of different regions of the micropatterns produced

  2. An Experimental Study of Force Involved in Manual Rebar Bending Process

    Science.gov (United States)

    Deepu, Sasi; Vishnu, Rajendran S.; Harish, Mohan T.; Bhavani, Rao R.

    2018-02-01

    The work presents an experimental method of understanding the force applied during a manual rebar bending process. The study tracks the force with the variation of the angle of bend and the elapsed time from the start to the end of a complete manual rebar bending process. A sample of expert rebar bending labourers are used for conducting the experiment and the data processed to set a performance standard. If a simulator based rebar bending training can be provided for a novice, this standard can be used as a matrix to define how close a novice rebar bender is closing to the expertise.

  3. Photolithographic Polymerization of Diacetylene-Containing Phospholipid Bilayers Studied by Multimode Atomic Force Microscopy

    NARCIS (Netherlands)

    Morigaki, Kenichi; Schönherr, Holger; Frank, Curtis W.; Knoll, Wolfgang

    2003-01-01

    Photopolymerization of the diacetylene-containing phospholipid 1,2-bis(10,12-tricosadiynoyl)-sn-glycero-3-phosphocholine (1) in substrate-supported planar lipid bilayers (SPBs) has been studied by using multimode atomic force microscopy (AFM). Monolayers and bilayers of 1 have been transferred onto

  4. A preliminary study to find out maximum occlusal bite force in Indian individuals

    DEFF Research Database (Denmark)

    Jain, Veena; Mathur, Vijay Prakash; Pillai, Rajath

    2014-01-01

    PURPOSE: This preliminary hospital based study was designed to measure the mean maximum bite force (MMBF) in healthy Indian individuals. An attempt was made to correlate MMBF with body mass index (BMI) and some of the anthropometric features. METHODOLOGY: A total of 358 healthy subjects in the ag...

  5. Researching Refugee and Forced Migration Studies: An Introduction to the Field and the Reference Literature.

    Science.gov (United States)

    Mason, Elisa

    1999-01-01

    Describes the evolution of refugee and forced migration studies, identifies factors that render it a challenging field to research, and highlights a variety of Internet-based and other electronic resources that can be used to locate monographs, periodicals, grey literature, and current information. Provides a bibliography of reference materials in…

  6. The Peaceful Uses of Military Forces. Praeger Special Studies in International Politics and Public Affairs.

    Science.gov (United States)

    Hanning, Hugh

    This study of the peaceful uses of military forces (PUMF) offers a compendium of information and principles for the planning and conduct of such PUMF activities as meeting disaster or emergency relief situations, education and training, and economic and social projects. The provision of training opportunities by the military is a means of…

  7. Determination of uranium by a gravimetric-volumetric titration method

    International Nuclear Information System (INIS)

    Krtil, J.

    1998-01-01

    A volumetric-gravimetric modification of a method for the determination of uranium based on the reduction of uranium to U (IV) in a phosphoric acid medium and titration with a standard potassium dichromate solution is described. More than 99% of the stoichiometric amount of the titrating solution is weighed and the remainder is added volumetrically by using the Mettler DL 40 RC Memotitrator. Computer interconnected with analytical balances collects continually the data on the analyzed samples and evaluates the results of determination. The method allows to determine uranium in samples of uranium metal, alloys, oxides, and ammonium diuranate by using aliquot portions containing 30 - 100 mg of uranium with the error of determination, expressed as the relative standard deviation, of 0.02 - 0.05%. (author)

  8. Coulometric thermometric titration of halides in molten calcium nitrate tetrahydrate.

    Science.gov (United States)

    Zsigrai, I J; Bartusz, D B

    1983-01-01

    A method for coulometric thermometric precipitation titrations of chloride, bromide and iodide in molten calcium nitrate tetrahydrate at 55 degrees with coulometrically generated silver ions has been developed. The change in temperature during the titration is followed with the aid of a thermistor bridge coupled to a recorder. To minimize the temperature effect of the passage of current through the melt, two thermistors are connected in opposition in the bridge, with one in the anodic and the other in the cathodic cell compartment. Amounts of 62-80 mumole of halide have been determined with relative error below 0.4% and relative standard deviation less than 2.7%. The relative error in determination of 40 mumole of iodide was + 2%.

  9. Application of cause-and-effect analysis to potentiometric titration.

    Science.gov (United States)

    Kufelnicki, A; Lis, S; Meinrath, G

    2005-08-01

    A first attempt has been made to interpret physicochemical data from potentiometric titration analysis in accordance with the complete measurement-uncertainty budget approach (bottom-up) of ISO and Eurachem. A cause-and-effect diagram is established and discussed. Titration data for arsenazo III are used as a basis for this discussion. The commercial software Superquad is used and applied within a computer-intensive resampling framework. The cause-and-effect diagram is applied to evaluation of seven protonation constants of arsenazo III in the pH range 2-10.7. The data interpretation is based on empirical probability distributions and their analysis by second-order correct confidence estimates. The evaluated data are applied in the calculation of a speciation diagram including uncertainty estimates using the probabilistic speciation software Ljungskile.

  10. Characterization of solid-solution interface by potentiometric titration and electrophoretic mobility

    International Nuclear Information System (INIS)

    Lindecker, C.; Drot, R.; Fourest, B.; Simoni, E.

    1999-01-01

    The study of nuclear waste storage in deep geological sites involves the understanding of processes which could produce a possible dispersion or retention of radioelements. The dispersion of solid particles in aqueous solution is consequently important to be characterized. In this bi-phased system it is necessary to determine the characteristics of the solid-solution interface. The method used of this study is the techniques of potentiometric titration applied to heterogeneous systems. The material studied were phosphate matrices which were synthesized in the laboratory. The dependence of their surface change upon the nature of the electrolytes was investigated

  11. Two-phase titration of cerium(3) by permanganate

    International Nuclear Information System (INIS)

    Lazarev, A.I.; Lazareva, V.I.; Gerko, V.V.

    1986-01-01

    Reaction of cerium (3) and permanganate was investigated at a room temperature depending on PH, concentrations of pyrophosphate, cerium (3), tetraphenylphosphonium and foreign compounds. Selective method of two-phase titration determination of cerium (3) by permanganate without using silver compounds, preliminary separation of chlorides, nitrates, was developed. The method was tested using alloys based on iron, nickel, REE, copper, cobalt (S r ≤0.008). Correctness is proved with method of standard additives

  12. Characterization of Native and Modified Starches by Potentiometric Titration

    OpenAIRE

    Soto, Diana; Urdaneta, Jose; Pernia, Kelly

    2014-01-01

    The use of potentiometric titration for the analysis and characterization of native and modified starches is highlighted. The polyelectrolytic behavior of oxidized starches (thermal and thermal-chemical oxidation), a graft copolymer of itaconic acid (IA) onto starch, and starch esters (mono- and diester itaconate) was compared with the behavior of native starch, the homopolymer, and the acid employed as a graft monomer and substituent. Starch esters showed higher percentages of acidity, follo...

  13. Determination of uranium and plutonium by sequential potentiometric titration

    International Nuclear Information System (INIS)

    Kato, Yoshiharu; Takahashi, Masao

    1976-01-01

    The determination of uranium and plutonium in mixed oxide fuels has been developed by sequential potentiometric titration. A weighed sample of uranium and plutonium oxides is dissolved in a mixture of nitric and hydrofluoric acids and the solution is fumed with sulfuric acid. After the reduction of uranium and plutonium to uranium(IV) and plutonium(III) by chromium(II) sulfate, 5 ml of buffer solution (KCl-HCl, pH 1.0) is added to the solution. Then the solution is diluted to 30 ml with water and the pH of the solution is adjusted to 1.0 -- 1.5 with 1 M sodium hydroxide. The solution is stirred until the oxidation of the excess of chromium(II) by air is completed. After the removal of dissolved oxygen by bubbling nitrogen through the solution for 10 minutes, uranium (IV) is titrated with 0.1 N cerium(IV) sulfate. Then, plutonium is titrated by 0.02 N cerium(IV) sulfate. When a mixture of uranium and plutonium is titrated with 0.1 N potassium dichromate potentiometrically, the potential change at the end point of plutonium is very small and the end point of uranium is also unclear when 0.1 N potassium permanganate is used as a titrant. In the present method, nitrate, fluoride and copper(II) interfere with the determination of plutonium and uranium. Iron interferes quantitatively with the determination of plutonium but not of uranium. Results obtained in applying the proposed method to 50 mg of mixtures of plutonium and uranium ((7.5 -- 50))% Pu were accurate to within 0.15 mg of each element. (auth.)

  14. Application of atomic force microscopy to the study of natural and model soil particles.

    Science.gov (United States)

    Cheng, S; Bryant, R; Doerr, S H; Rhodri Williams, P; Wright, C J

    2008-09-01

    The structure and surface chemistry of soil particles has extensive impact on many bulk scale properties and processes of soil systems and consequently the environments that they support. There are a number of physiochemical mechanisms that operate at the nanoscale which affect the soil's capability to maintain native vegetation and crops; this includes soil hydrophobicity and the soil's capacity to hold water and nutrients. The present study used atomic force microscopy in a novel approach to provide unique insight into the nanoscale properties of natural soil particles that control the physiochemical interaction of material within the soil column. There have been few atomic force microscopy studies of soil, perhaps a reflection of the heterogeneous nature of the system. The present study adopted an imaging and force measurement research strategy that accounted for the heterogeneity and used model systems to aid interpretation. The surface roughness of natural soil particles increased with depth in the soil column a consequence of the attachment of organic material within the crevices of the soil particles. The roughness root mean square calculated from ten 25 microm(2) images for five different soil particles from a Netherlands soil was 53.0 nm, 68.0 nm, 92.2 nm and 106.4 nm for the respective soil depths of 0-10 cm, 10-20 cm, 20-30 cm and 30-40 cm. A novel analysis method of atomic force microscopy phase images based on phase angle distribution across a surface was used to interpret the nanoscale distribution of organic material attached to natural and model soil particles. Phase angle distributions obtained from phase images of model surfaces were found to be bimodal, indicating multiple layers of material, which changed with the concentration of adsorbed humic acid. Phase angle distributions obtained from phase images of natural soil particles indicated a trend of decreasing surface coverage with increasing depth in the soil column. This was consistent with

  15. 76 FR 38669 - Submission for OMB Review; Comment Request; Food Reporting Comparison Study (FORCS) and Food and...

    Science.gov (United States)

    2011-07-01

    ...; Comment Request; Food Reporting Comparison Study (FORCS) and Food and Eating Assessment Study (FEAST) (NCI... Collection: Title: Food Reporting Comparison Study (FORCS) and Food and Eating Assessment Study (FEAST) (NCI... (in Minnesota, California, and Michigan) between ages 20 and 70 years. For the FEAST study...

  16. Protometric thermometric titrations of sparingly soluble compounds in water in the presence of n-octanol.

    Science.gov (United States)

    Burgot, G; Burgot, J-L

    2002-10-15

    Thermometric titrimetry permits titration of acido-basic compounds in water in the presence of n-octanol. n-Octanol permits the solubilization of protolytes and moreover may also displace the equilibria of the titration reactions. Hydrochlorides of highly insoluble derivatives such as phenothiazine derivatives can be titrated with satisfactory accuracy and precision by sodium hydroxide despite their high pK(a) values. Likewise barbiturate salts can be titrated by hydrochloric acid. In the case of some salts, the methodology may permit the sequential titration of the ion and counter ion. Copyright 2002 Elsevier Science B.V.

  17. Applications of atomic force microscopy to the studies of biomaterials in biomolecular systems

    Science.gov (United States)

    Ma, Xiang

    Atomic force microscopy (AFM) is a unique tool for the studies of nanoscale structures and interactions. In this dissertation, I applied AFM to study transitions among multiple states of biomaterials in three different microscopic biomolecular systems: MukB-dependent DNA condensation, holdfast adhesion, and virus elasticity. To elucidate the mechanism of MukB-dependent DNA condensation, I have studied the conformational changes of MukB proteins as indicators for the strength of interactions between MukB, DNA and other molecular factors, such as magnesium and ParC proteins, using high-resolution AFM imaging. To determine the physical origins of holdfast adhesion, I have investigated the dynamics of adhesive force development of the holdfast, employing AFM force spectroscopy. By measuring rupture forces between the holdfast and the substrate, I showed that the holdfast adhesion is strongly time-dependent and involves transformations at multiple time scales. Understanding the mechanisms of adhesion force development of the holdfast will be critical for future engineering of holdfasts properties for various applications. Finally, I have examined the elasticity of self-assembled hepatitis B virus-like particles (HBV VLPs) and brome mosaic virus (BMV) in response to changes of pH and salinity, using AFM nanoindentation. The distributions of elasticity were mapped on a single particle level and compared between empty, RNA- and gold-filled HBV VLPs. I found that a single HBV VLP showed heterogeneous distribution of elasticity and a two-step buckling transition, suggesting a discrete property of HBV capsids. For BMV, I have showed that viruses containing different RNA molecules can be distinguished by mechanical measurements, while they are indistinguishable by morphology. I also studied the effect of pH on the elastic behaviors of three-particle BMV and R3/4 BMV. This study can yield insights into RNA presentation/release mechanisms, and could help us to design novel drug

  18. The Social Determinants of Health in Military Forces of Iran: A Qualitative Study

    Science.gov (United States)

    Sanaeinasab, Hormoz; Ghanei, Mostafa; Mehrabi Tavana, Ali; Ravangard, Ramin; Karamali, Mazyar

    2015-01-01

    Providing effective health interventions and achieving equity in health need to apply the community-based approaches such as social determinants of health. In the military organizations, these determinants have received less attention from the military health researchers and policymakers. Therefore, this study aimed to identify and explain the social determinants affecting the health of military forces in Iran. This was a qualitative study which was conducted in 2014. The required data were collected through semistructured interviews and analyzed through Conventional Content Analysis. The studied sample consisted of 22 military health experts, policymakers, and senior managers selected using purposeful sampling method with maximum variation sampling. MAXQDA.2007 was used to analyze the collected data. After analyzing the collected data, two main contents, that is, “general social determinants of health” and “military social determinants of health,” with 22 themes and 90 subthemes were identified as the social determinants of military forces' health. Main themes were religious rule, spirituality promotion policies, international military factors, military command, and so forth. Given the role and importance of social factors determining the military forces' health, it can be recommended that the military organizations should pay more attention to these determinants in making policies and creating social, economic, and cultural structures for their forces. PMID:26379716

  19. The Mobile Insulin Titration Intervention (MITI) for Insulin Adjustment in an Urban, Low-Income Population: Randomized Controlled Trial.

    Science.gov (United States)

    Levy, Natalie; Moynihan, Victoria; Nilo, Annielyn; Singer, Karyn; Bernik, Lidia S; Etiebet, Mary-Ann; Fang, Yixin; Cho, James; Natarajan, Sundar

    2015-07-17

    Diabetes patients are usually started on a low dose of insulin and their dose is adjusted or "titrated" according to their blood glucose levels. Insulin titration administered through face-to-face visits with a clinician can be time consuming and logistically burdensome for patients, especially those of low socioeconomic status (SES). Given the wide use of mobile phones among this population, there is the potential to use short message service (SMS) text messaging and phone calls to perform insulin titration remotely. The goals of this pilot study were to (1) evaluate if our Mobile Insulin Titration Intervention (MITI) intervention using text messaging and phone calls was effective in helping patients reach their optimal insulin glargine dose within 12 weeks, (2) assess the feasibility of the intervention within our clinic setting and patient population, (3) collect data on the cost savings associated with the intervention, and (4) measure patient satisfaction with the intervention. This was a pilot study evaluating an intervention for patients requiring insulin glargine titration in the outpatient medical clinic of Bellevue Hospital Center in New York City. Patients in the intervention arm received weekday SMS text messages from a health management platform requesting their fasting blood glucose values. The clinic's diabetes nurse educator monitored the texted responses on the platform website each weekday for alarm values. Once a week, the nurse reviewed the glucose values, consulted the MITI titration algorithm, and called patients to adjust their insulin dose. Patients in the usual care arm continued to receive their standard clinic care for insulin titration. The primary outcome was whether a patient reached his/her optimal insulin glargine dose within 12 weeks. A total of 61 patients consented and were randomized into the study. A significantly greater proportion of patients in the intervention arm reached their optimal insulin glargine dose than patients in

  20. Effects of fixed or self-titrated dosages of Sativex on cannabis withdrawal and cravings

    Science.gov (United States)

    Trigo, Jose M.; Lagzdins, Dina; Rehm, Jürgen; Selby, Peter; Gamaleddin, Islam; Fischer, Benedikt; Barnes, Allan J.; Huestis, Marilyn A.; Le Foll, Bernard

    2016-01-01

    Background There is currently no pharmacological treatment approved for cannabis dependence. In this proof of concept study, we assessed the feasibility/effects of fixed and self-titrated dosages of Sativex (1:1, Δ9-tetrahydrocannabinol (THC)/cannabidiol (CBD)) on craving and withdrawal from cannabis among nine community-recruited cannabis-dependent subjects. Methods Participants underwent an 8-week double-blind placebo-controlled trial (an ABACADAE design), with four smoke as usual conditions (SAU) (A) separated by four cannabis abstinence conditions (B–E), with administration of either self-titrated/fixed doses of placebo or Sativex (up to 108 mg THC/100 mg CBD). The order of medication administration during abstinence conditions was randomized and counterbalanced. Withdrawal symptoms and craving were assessed using the Cannabis Withdrawal Scale (CWS), Marijuana Withdrawal Checklist (MWC) and Marijuana Craving Questionnaire (MCQ). Medication use was assessed during the study by means of self-reports, vial weight control, toxicology and metabolite analysis. Cannabis use was assessed by means of self-reports. Results High fixed doses of Sativex were well tolerated and significantly reduced cannabis withdrawal during abstinence, but not craving, as compared to placebo. Self-titrated doses were lower and showed limited efficacy as compared to high fixed doses. Participants reported a significantly lower “high” following Sativex or placebo as compared to SAU conditions. Cannabis/medication use along the study, as per self-reports, suggests compliance with the study conditions. Conclusions The results found in this proof of concept study warrant further systematic exploration of Sativex as a treatment option for cannabis withdrawal and dependence. PMID:26925704

  1. Effects of fixed or self-titrated dosages of Sativex on cannabis withdrawal and cravings.

    Science.gov (United States)

    Trigo, Jose M; Lagzdins, Dina; Rehm, Jürgen; Selby, Peter; Gamaleddin, Islam; Fischer, Benedikt; Barnes, Allan J; Huestis, Marilyn A; Le Foll, Bernard

    2016-04-01

    There is currently no pharmacological treatment approved for cannabis dependence. In this proof of concept study, we assessed the feasibility/effects of fixed and self-titrated dosages of Sativex (1:1, Δ(9)-tetrahydrocannabinol (THC)/cannabidiol (CBD)) on craving and withdrawal from cannabis among nine community-recruited cannabis-dependent subjects. Participants underwent an 8-week double-blind placebo-controlled trial (an ABACADAE design), with four smoke as usual conditions (SAU) (A) separated by four cannabis abstinence conditions (B-E), with administration of either self-titrated/fixed doses of placebo or Sativex (up to 108 mg THC/100 mg CBD). The order of medication administration during abstinence conditions was randomized and counterbalanced. Withdrawal symptoms and craving were assessed using the Cannabis Withdrawal Scale (CWS), Marijuana Withdrawal Checklist (MWC) and Marijuana Craving Questionnaire (MCQ). Medication use was assessed during the study by means of self-reports, vial weight control, toxicology and metabolite analysis. Cannabis use was assessed by means of self-reports. High fixed doses of Sativex were well tolerated and significantly reduced cannabis withdrawal during abstinence, but not craving, as compared to placebo. Self-titrated doses were lower and showed limited efficacy as compared to high fixed doses. Participants reported a significantly lower "high" following Sativex or placebo as compared to SAU conditions. Cannabis/medication use along the study, as per self-reports, suggests compliance with the study conditions. The results found in this proof of concept study warrant further systematic exploration of Sativex as a treatment option for cannabis withdrawal and dependence. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  2. Force spectroscopy studies on protein-ligand interactions: a single protein mechanics perspective.

    Science.gov (United States)

    Hu, Xiaotang; Li, Hongbin

    2014-10-01

    Protein-ligand interactions are ubiquitous and play important roles in almost every biological process. The direct elucidation of the thermodynamic, structural and functional consequences of protein-ligand interactions is thus of critical importance to decipher the mechanism underlying these biological processes. A toolbox containing a variety of powerful techniques has been developed to quantitatively study protein-ligand interactions in vitro as well as in living systems. The development of atomic force microscopy-based single molecule force spectroscopy techniques has expanded this toolbox and made it possible to directly probe the mechanical consequence of ligand binding on proteins. Many recent experiments have revealed how ligand binding affects the mechanical stability and mechanical unfolding dynamics of proteins, and provided mechanistic understanding on these effects. The enhancement effect of mechanical stability by ligand binding has been used to help tune the mechanical stability of proteins in a rational manner and develop novel functional binding assays for protein-ligand interactions. Single molecule force spectroscopy studies have started to shed new lights on the structural and functional consequence of ligand binding on proteins that bear force under their biological settings. Copyright © 2014 Federation of European Biochemical Societies. Published by Elsevier B.V. All rights reserved.

  3. Three different up-titration regimens of ponesimod, an S1P1 receptor modulator, in healthy subjects.

    Science.gov (United States)

    Scherz, Michael W; Brossard, Patrick; D'Ambrosio, Daniele; Ipek, Murat; Dingemanse, Jasper

    2015-06-01

    Ponesimod is a selective S1P1 receptor modulator, and induces dose-dependent reduction of circulating lymphocytes upon oral dosing. Previous studies showed that single doses up to 75 mg or multiple doses up to 40 mg once daily are well tolerated, and heart rate (HR) reduction and atrio-ventricular conduction delays upon treatment initiation are reduced by gradual up-titration to the maintenance dose. This single-center, open-label, randomized, multiple-dose, 3-treatment, 3-way crossover study compared the tolerability, safety, pharmacokinetics, cardiodynamics, and effects on lymphocytes of 3 different up-titration regimens of ponesimod in healthy male and female subjects. Up-titration regimens comprised escalating periods of b.i.d. dosing (2.5 or 5 mg) and q.d. dosing (10 or 20 mg or both). After the third up-titration period a variable-duration washout period of 1-3 days was followed by re-challenge with a single 20-mg dose of ponesimod. Adverse events were transient and mild to moderate in intensity, not different between regimens. HR decrease after the first dose was greater than after all subsequent doses, including up-titration doses. Little or no HR change was observed with morning doses of b.i.d. regimens, suggesting that 2.5 and 5 mg b.i.d. are sufficient to sustain cardiac desensitization for the 12-hours dosing interval. © 2015, The American College of Clinical Pharmacology.

  4. Electrophoretic separation of alginic sodium diester and sodium hexametaphosphate in chondroitin sulfate that interfere with the cetylpyridinium chloride titration assay.

    Science.gov (United States)

    Weiguo, Zhang; Giancaspro, Gabriel; Adams, Kristie M; Neal-Kababick, James; Hildreth, Jana; Li, Aishan; Roman, Mark C; Betz, Joseph M

    2014-01-01

    The most commonly used chondroitin sulfate (CS) assay method is cetylpyridinium chloride (CPC) titration. Cellulose acetate membrane electrophoresis (CAME) is the technique used for detection of impurities in the U.S. Pharmacopeia's CS monograph. Because CPC titration is a relatively nonspecific quantitative technique, the apparent amount of CS as determined by CPC titration alone may not reflect the true amount of CS due to possible interference with the CPC assay by impurities that contain CPC titratable functional groups. When CAME is used in conjunction with CPC titration, certain non-CS and adulterants can be visualized and estimated, and a true value for CS can be assigned once the presence of these non-CS impurities has been ruled out. This study examines conjunct application of CPC and CAME in ascertaining CS assay and purity in the presence of certain adulterants. These include propylene glycol alginate sulfate sodium, known in commerce as alginic sodium diester (ASD), and Zero One (Z1), a water-soluble agent newly reported in the CS marketplace and subsequently identified as sodium hexametaphosphate. ASD, Z1, and CS are similar in physical appearance and solubility in water and ethanol. They are also titratable anions and form ionic pairs with CPC, therefore interfering with the CPC titration assay for CS CAME separates these adulterants from each other and from CS by differences in their electrophoretic mobility. CAME is able to detect these impurities in CS at levels as low as 0.66% by weight. Although it is recommended that a method for detecting impurities (e.g., CAME) be used in cormbination with relatively nonspecific assay methods such as CPC titration, this is seldom done in practice. Assay results for CS derived fromn CPC titration may, therefore, be misleading, leaving the CS supply chain vulnerable to adulteration. In this study, the authors investigated ASD and Z1 adulteration of CS and developed an electrophoretic separation of these

  5. Potential benefits of slow titration of paroxetine treatment in an elderly population: eight-week results from a naturalistic setting.

    Science.gov (United States)

    Gibiino, Sara; Mori, Elisa; De Ronchi, Diana; Serretti, Alessandro

    2013-08-01

    Late-life depression, often in association with anxiety, affects approximately 15% of individuals older than 65 years. Selective serotonin reuptake inhibitors are the first-line treatment but could be responsible of an early exacerbation of anxiety, possibly reduced by a very gradual titration of drugs. The main aim of this study is to compare gradual and rapid (standard) titration of paroxetine in an elderly population. In a naturalistic setting, 50 elderly (≥60 years old) outpatients with unipolar mood disorder or anxiety disorder were naturalistically assigned to abrupt initiation of 10 mg of paroxetine or to a gradual increase with 2.5 mg on alternate days up to 10 mg in 7 days. Then dosage could be maintained at 10 mg or increased according to clinical response. Primary outcome was efficacy as assessed by the Hamilton Depression Rating Scale (HAM-D) 21, HAM-D symptom subscales (core, psychic anxiety, somatic anxiety cluster), and Hamilton Anxiety Rating Scale changes. Secondary outcome was evaluation of overall dropouts at eighth week and evaluation of most common adverse effects through the global judgment of the Dosage Record and Treatment Emergent Symptom Scale. All data were recorded weekly for the first 8 weeks of treatment (with 1 more evaluation after 3 days from the baseline). Samples were comparable at baseline, with patients in gradual titration showing a higher level of psychic anxiety. During the first 3 days of treatment, a significant worsening in psychic anxiety was observed in patients treated abruptly with 10 mg of paroxetine (difference in HAM-D psychic anxiety subscale from baseline: 110.61% vs 89.38% with rapid and slow titration, respectively; t test P = 0.03). Overall, a significantly greater improvement in depressive and anxious symptoms favored gradual titration (HAM-D core cluster and HAM-D psychic anxiety cluster, respectively, P = 0.014 and P titration). Our results suggest that a gradual titration of paroxetine could avoid the

  6. Dose Response Effects of Lisdexamfetamine Dimesylate Treatment in Adults with ADHD: An Exploratory Study

    Science.gov (United States)

    Faraone, Stephen V.; Spencer, Thomas J.; Kollins, Scott H.; Glatt, Stephen J.; Goodman, David

    2012-01-01

    Objective: To explore dose-response effects of lisdexamfetamine dimesylate (LDX) treatment for ADHD. Method: This was a 4-week, randomized, double-blinded, placebo-controlled, parallel-group, forced-dose titration study in adult participants, aged 18 to 55 years, meeting "Diagnostic and Statistical Manual of Mental Disorders" (4th ed., text rev.)…

  7. Prediction of peak back compressive forces as a function of lifting speed and compressive forces at lift origin and destination - a pilot study.

    Science.gov (United States)

    Greenland, Kasey O; Merryweather, Andrew S; Bloswick, Donald S

    2011-09-01

    To determine the feasibility of predicting static and dynamic peak back-compressive forces based on (1) static back compressive force values at the lift origin and destination and (2) lifting speed. Ten male subjects performed symmetric mid-sagittal floor-to-shoulder, floor-to-waist, and waist-to-shoulder lifts at three different speeds (slow, medium, and fast), and with two different loads (light and heavy). Two-dimensional kinematics and kinetics were captured. Linear regression analyses were used to develop prediction equations, the amount of predictability, and significance for static and dynamic peak back-compressive forces based on a static origin and destination average (SODA) back-compressive force. Static and dynamic peak back-compressive forces were highly predicted by the SODA, with R(2) values ranging from 0.830 to 0.947. Slopes were significantly different between slow and fast lifting speeds (p assessments at the origin and destination of a lifting task. This could be valuable for enhancing job design and analysis in the workplace and for large-scale studies where a full analysis of each lifting task is not feasible.

  8. Experimental study of cooling BIPV modules by forced convection in the air channel

    International Nuclear Information System (INIS)

    Kaiser, A.S.; Zamora, B.; Mazón, R.; García, J.R.; Vera, F.

    2014-01-01

    Highlights: • An experimental setup for studying the effects of forced convection on cell temperature. • The induced velocity within the forced convection channel significantly affects the PV cooling. • Correlations for the Ross coefficient, module temperature, efficiency, and power output. • Prediction of the thermal behavior of the PV module in BIPV configurations. - Abstract: The efficiency of photovoltaic systems depends mainly on the cell temperature. Frequently, the PV collectors are installed on the top of the building. One cost effective method to regulate the temperature of rooftop integrated photovoltaic panels is to provide an open air channel beneath the panel. The cell temperature of these PV modules is very much influenced by the capability of ventilating this channel. The ventilation may be modified by different factors such as the wind velocity, the air gap size, and the forced convection induced by a fan or by a conventional air conditioning system. This paper describes an experimental setup to study the influence of the air gap size and the forced ventilation on the cell temperature (and consequently on the electrical efficiency of the PV module) of a BIPV configuration, for different values of the incident solar radiation, ambient temperatures, and aspect ratios, as well as for several forced ventilation conditions. Semi empirical correlations for the Ross coefficient, module temperature, electrical efficiency, and power output are proposed, showing a good agreement with respect to experimental measurements. A critical channel aspect ratio close to 0.11 can be considered to minimize overheating of PV devices. For a duct velocity V v = 6 m/s, a power output increase of 19% is observed over the natural ventilation case (V v = 0.5 m/s)

  9. Influence of different beverages on the force degradation of intermaxillary elastics: an in vitro study

    Directory of Open Access Journals (Sweden)

    Jorge César Borges Leão Filho

    2013-04-01

    Full Text Available Objective: The aim of this study was to evaluate in vitro the effects of frequently ingested beverages on force degradation of intermaxillary elastics. Material and Methods: One hundred and eighty 1/4-inch intermaxillary elastics (TP Orthodontics were immersed into six different beverages: (1 Coca-Cola®; (2 Beer; (3 Orange juice; (4 Red wine; (5 Coffee and (6 artificial saliva (control. The period of immersion was 15 min for the first and second cycles and 30 min for the third to fifth cycles. Tensile forces were read in a tensile testing machine before and after the five immersion cycles. One-way repeated measures ANOVA was used to identify significant differences. Results: Force degradation was seen in all evaluated groups and at all observation periods (p<0.05. A greater degree of degradation was present at the initial periods, decreasing gradually over time. However, no statistically significant differences were seen among groups at the same periods, showing that different groups behaved similarly. Conclusions: The chemical nature of the evaluated beverages was not able to influence the degree of force degradation at all observation periods.

  10. Study of adhesion of vertically aligned carbon nanotubes to a substrate by atomic-force microscopy

    Science.gov (United States)

    Ageev, O. A.; Blinov, Yu. F.; Il'ina, M. V.; Il'in, O. I.; Smirnov, V. A.; Tsukanova, O. G.

    2016-02-01

    The adhesion to a substrate of vertically aligned carbon nanotubes (VA CNT) produced by plasmaenhanced chemical vapor deposition has been experimentally studied by atomic-force microscopy in the current spectroscopy mode. The longitudinal deformation of VA CNT by applying an external electric field has been simulated. Based on the results, a technique of determining VA CNT adhesion to a substrate has been developed that is used to measure the adhesion strength of connecting VA CNT to a substrate. The adhesion to a substrate of VA CNT 70-120 nm in diameter varies from 0.55 to 1.19 mJ/m2, and the adhesion force from 92.5 to 226.1 nN. When applying a mechanical load, the adhesion strength of the connecting VA CNT to a substrate is 714.1 ± 138.4 MPa, and the corresponding detachment force increases from 1.93 to 10.33 μN with an increase in the VA CNT diameter. As an external electric field is applied, the adhesion strength is almost doubled and is 1.43 ± 0.29 GPa, and the corresponding detachment force is changed from 3.83 to 20.02 μN. The results can be used in the design of technological processes of formation of emission structures, VA CNT-based elements for vacuum microelectronics and micro- and nanosystem engineering, and also the methods of probe nanodiagnostics of VA CNT.

  11. Experimental study of tyre/road contact forces in rolling conditions for noise prediction

    Science.gov (United States)

    Cesbron, Julien; Anfosso-Lédée, Fabienne; Duhamel, Denis; Ping Yin, Hai; Le Houédec, Donatien

    2009-02-01

    This paper deals with the experimental study of dynamical tyre/road contact for noise prediction. In situ measurements of contact forces and close proximity noise levels were carried out for a slick tyre rolling on six different road surfaces between 30 and 50 km/h. Additional texture profiles of the tested surfaces were taken on the wheel track. Normal contact stresses were measured at a sampling frequency of 10752 Hz using a line of pressure sensitive cells placed both along and perpendicular to the rolling direction. The contact areas obtained during rolling were smaller than in static conditions. This is mainly explained by the dynamical properties of tyre compounds, like the viscoelastic behaviour of the rubber. Additionally the root-mean-square of the resultant contact forces at various speeds was in the same order for a given road surface, while their spectra were quite different. This is certainly due to a spectral influence of bending waves propagating in the tyre during rolling, especially when the wavelength is small in comparison with the size of the contact patch. Finally, the levels of contact forces and close proximity noise measured at 30 km/h were correlated. Additional correlations with texture levels were performed. The results show that the macro-texture generates contact forces linearly around 800 Hz and consequently noise levels between 500 and 1000 Hz via the vibrations transmitted to the tyre.

  12. Influence of different beverages on the force degradation of intermaxillary elastics: an in vitro study.

    Science.gov (United States)

    Leão Filho, Jorge César Borges; Gallo, Daphine Beatriz; Santana, Regis Meller; Guariza-Filho, Odilon; Camargo, Elisa Souza; Tanaka, Orlando Motohiro

    2013-01-01

    The aim of this study was to evaluate in vitro the effects of frequently ingested beverages on force degradation of intermaxillary elastics. One hundred and eighty 1/4-inch intermaxillary elastics (TP Orthodontics) were immersed into six different beverages: (1) Coca-Cola®; (2) Beer; (3) Orange juice; (4) Red wine; (5) Coffee and (6) artificial saliva (control). The period of immersion was 15 min for the first and second cycles and 30 min for the third to fifth cycles. Tensile forces were read in a tensile testing machine before and after the five immersion cycles. One-way repeated measures ANOVA was used to identify significant differences. Force degradation was seen in all evaluated groups and at all observation periods (pdegradation was present at the initial periods, decreasing gradually over time. However, no statistically significant differences were seen among groups at the same periods, showing that different groups behaved similarly. The chemical nature of the evaluated beverages was not able to influence the degree of force degradation at all observation periods.

  13. Theoretical and experimental studies on transient forced convection heat transfer of helium gas

    International Nuclear Information System (INIS)

    Liu, Qiusheng; Fukuda, Katsuya; Shibahara, Makoto

    2008-01-01

    Forced convection transient heat transfer for helium gas at various periods of exponential increase of heat input to a horizontal cylinder and a plate (ribbon) one was experimentally and theoretically studied. In the experimental studies, the authors measured heat flux, surface temperature, and transient heat transfer coefficients for forced convection flow of helium gas over a horizontal cylinder and a plate (ribbon) one under wide experimental conditions. Empirical correlations for quasi-steady-state heat transfer and transient heat transfer were obtained based on the experimental data. In the theoretical study, transient heat transfer was numerically solved based on a turbulent flow model. The values of numerical solution for surface temperature and heat flux were compared and discussed with authors' experimental data. (author)

  14. A new approach to flow-batch titration. A monosegmented flow titrator with coulometric reagent generation and potentiometric or biamperometric detection.

    Science.gov (United States)

    de Aquino, Emerson Vidal; Rohwedder, Jarbas José Rodrigues; Pasquini, Celio

    2006-11-01

    Monosegmented flow analysis (MSFA) has been used as a flow-batch system to produce a simple, robust, and mechanized titrator that enables true titrations to be performed without the use of standards. This paper also introduces the use of coulometry with monosegmented titration by proposing a versatile flow cell. Coulometric generation of the titrand is attractive for titrations performed in monosegmented systems, because the reagent can be added without increasing the volume of sample injected. Also, biamperomeric and potentiometric detection of titration end-points can increase the versatility of the monosegmented titrator. The cell integrates coulometric generation of the titrand with detection of end-point by potentiometry or biamperometry. The resulting titrator is a flow-batch system in which the liquid monosegment, constrained by the interfaces of the gaseous carrier stream, plays the role of a sample of known volume to be titrated. The system has been used for determination of ascorbic acid, by coulometric generation of I2 with biamperometric detection, and for determination of Fe(II), by coulometric generation of Ce(IV) with potentiometric detection of the end-point, both in feed supplements.

  15. Investigation of zirconium oxychloride interaction with acetylacetone by the method of pH-metric titration

    International Nuclear Information System (INIS)

    Zharkova, N.Ya.; Martynenko, L.I.; Dzyubenko, N.G.

    1989-01-01

    Interaction of zirconium oxychloride with acetylacetone (NA) was studied by the method of pH-metric titration using KOH and NH 4 OH as neutralizing agents. It is shown that processes of hydrolysis and complexation complete in the system. It was established that decrease of hydrolysis of Zr-containing complex forms and ZrA 4 · 10H 2 O isolation takes place in relatively concentrated solutions of ZrOCl 2 and NA mixture, taken with 1:4 molar ratio when using NH 4 OH as neutralizing agent

  16. Indirect potentiometric titration of ascorbic acid in pharmaceutical preparations using copper based mercury film electrode.

    Science.gov (United States)

    Abdul Kamal Nazer, Meeran Mohideen; Hameed, Abdul Rahman Shahul; Riyazuddin, Patel

    2004-01-01

    A simple and rapid potentiometric method for the estimation of ascorbic acid in pharmaceutical dosage forms has been developed. The method is based on treating ascorbic acid with iodine and titration of the iodide produced equivalent to ascorbic acid with silver nitrate using Copper Based Mercury Film Electrode (CBMFE) as an indicator electrode. Interference study was carried to check possible interference of usual excipients and other vitamins. The precision and accuracy of the method was assessed by the application of lack-of-fit test and other statistical methods. The results of the proposed method and British Pharmacopoeia method were compared using F and t-statistical tests of significance.

  17. Numerical and experimental study on vorticity measurement in liquid metal using local Lorentz force velocimetry

    Science.gov (United States)

    Hernández, Daniel; Marangoni, Rafael; Schleichert, Jan; Karcher, Christian; Fröhlich, Thomas; Wondrak, Thomas

    2018-03-01

    Local Lorentz force velocimetry (local LFV) is a contactless velocity measurement technique for liquid metals. Due to the relative movement between an electrically conductive fluid and a static applied magnetic field, eddy currents and a flow-braking Lorentz force are generated inside the metal melt. This force is proportional to the flow rate or to the local velocity, depending on the volume subset of the flow spanned by the magnetic field. By using small-size magnets, a localized magnetic field distribution is achieved allowing a local velocity assessment in the region adjacent to the wall. In the present study, we describe a numerical model of our experiments at a continuous caster model where the working fluid is GaInSn in eutectic composition. Our main goal is to demonstrate that this electromagnetic technique can be applied to measure vorticity distributions, i.e. to resolve velocity gradients as well. Our results show that by using a cross-shaped magnet system, the magnitude of the torque perpendicular to the surface of the mold significantly increases improving its measurement in a liquid metal flow. According to our numerical model, this torque correlates with the vorticity of the velocity in this direction. Before validating our numerical predictions, an electromagnetic dry calibration of the measurement system composed of a multicomponent force and torque sensor and a cross-shaped magnet was done using a rotating disk made of aluminum. The sensor is able to measure simultaneously all three components of force and torque, respectively. This calibration step cannot be avoided and it is used for an accurate definition of the center of the magnet with respect to the sensor’s coordinate system for torque measurements. Finally, we present the results of the experiments at the mini-LIMMCAST facility showing a good agreement with the numerical model.

  18. Automated high-pressure titration system with in situ infrared spectroscopic detection

    International Nuclear Information System (INIS)

    Thompson, Christopher J.; Martin, Paul F.; Chen, Jeffrey; Schaef, Herbert T.; Rosso, Kevin M.; Felmy, Andrew R.; Loring, John S.; Benezeth, Pascale

    2014-01-01

    A fully automated titration system with infrared detection was developed for investigating interfacial chemistry at high pressures. The apparatus consists of a high-pressure fluid generation and delivery system coupled to a high-pressure cell with infrared optics. A manifold of electronically actuated valves is used to direct pressurized fluids into the cell. Precise reagent additions to the pressurized cell are made with calibrated tubing loops that are filled with reagent and placed in-line with the cell and a syringe pump. The cell's infrared optics facilitate both transmission and attenuated total reflection (ATR) measurements to monitor bulk-fluid composition and solid-surface phenomena such as adsorption, desorption, complexation, dissolution, and precipitation. Switching between the two measurement modes is accomplished with moveable mirrors that direct the light path of a Fourier transform infrared spectrometer into the cell along transmission or ATR light paths. The versatility of the high-pressure IR titration system was demonstrated with three case studies. First, we titrated water into supercritical CO 2 (scCO 2 ) to generate an infrared calibration curve and determine the solubility of water in CO 2 at 50 °C and 90 bar. Next, we characterized the partitioning of water between a montmorillonite clay and scCO 2 at 50 °C and 90 bar. Transmission-mode spectra were used to quantify changes in the clay's sorbed water concentration as a function of scCO 2 hydration, and ATR measurements provided insights into competitive residency of water and CO 2 on the clay surface and in the interlayer. Finally, we demonstrated how time-dependent studies can be conducted with the system by monitoring the carbonation reaction of forsterite (Mg 2 SiO 4 ) in water-bearing scCO 2 at 50 °C and 90 bar. Immediately after water dissolved in the scCO 2 , a thin film of adsorbed water formed on the mineral surface, and the film thickness increased with time as the

  19. Charge characteristics of humic and fulvic acids: comparative analysis by colloid titration and potentiometric titration with continuous pK-distribution function model.

    Science.gov (United States)

    Bratskaya, S; Golikov, A; Lutsenko, T; Nesterova, O; Dudarchik, V

    2008-09-01

    Charge characteristics of humic and fulvic acids of a different origin (inshore soils, peat, marine sediments, and soil (lysimetric) waters) were evaluated by means of two alternative methods - colloid titration and potentiometric titration. In order to elucidate possible limitations of the colloid titration as an express method of analysis of low content of humic substances we monitored changes in acid-base properties and charge densities of humic substances with soil depth, fractionation, and origin. We have shown that both factors - strength of acidic groups and molecular weight distribution in humic and fulvic acids - can affect the reliability of colloid titration. Due to deviations from 1:1 stoichiometry in interactions of humic substances with polymeric cationic titrant, the colloid titration can underestimate total acidity (charge density) of humic substances with domination of weak acidic functional groups (pK>6) and high content of the fractions with molecular weight below 1kDa.

  20. The effect of cigarette smoke extract on thrombomodulin-thrombin binding: an atomic force microscopy study.

    Science.gov (United States)

    Wei, Yujie; Zhang, Xuejie; Xu, Li; Yi, Shaoqiong; Li, Yi; Fang, Xiaohong; Liu, Huiliang

    2012-10-01

    Cigarette smoking is a well-known risk factor for cardiovascular disease. Smoking can cause vascular endothelial dysfunction and consequently trigger haemostatic activation and thrombosis. However, the mechanism of how smoking promotes thrombosis is not fully understood. Thrombosis is associated with the imbalance of the coagulant system due to endothelial dysfunction. As a vital anticoagulation cofactor, thrombomodulin (TM) located on the endothelial cell surface is able to regulate intravascular coagulation by binding to thrombin, and the binding results in thrombosis inhibition. This work focused on the effects of cigarette smoke extract (CSE) on TM-thrombin binding by atomic force microscopy (AFM) based single-molecule force spectroscopy. The results from both in vitro and live-cell experiments indicated that CSE could notably reduce the binding probability of TM and thrombin. This study provided a new approach and new evidence for studying the mechanism of thrombosis triggered by cigarette smoking.

  1. RACORO continental boundary layer cloud investigations: 1. Case study development and ensemble large-scale forcings

    Science.gov (United States)

    Vogelmann, Andrew M.; Fridlind, Ann M.; Toto, Tami; Endo, Satoshi; Lin, Wuyin; Wang, Jian; Feng, Sha; Zhang, Yunyan; Turner, David D.; Liu, Yangang; Li, Zhijin; Xie, Shaocheng; Ackerman, Andrew S.; Zhang, Minghua; Khairoutdinov, Marat

    2015-06-01

    Observation-based modeling case studies of continental boundary layer clouds have been developed to study cloudy boundary layers, aerosol influences upon them, and their representation in cloud- and global-scale models. Three 60 h case study periods span the temporal evolution of cumulus, stratiform, and drizzling boundary layer cloud systems, representing mixed and transitional states rather than idealized or canonical cases. Based on in situ measurements from the Routine AAF (Atmospheric Radiation Measurement (ARM) Aerial Facility) CLOWD (Clouds with Low Optical Water Depth) Optical Radiative Observations (RACORO) field campaign and remote sensing observations, the cases are designed with a modular configuration to simplify use in large-eddy simulations (LES) and single-column models. Aircraft measurements of aerosol number size distribution are fit to lognormal functions for concise representation in models. Values of the aerosol hygroscopicity parameter, κ, are derived from observations to be 0.10, which are lower than the 0.3 typical over continents and suggestive of a large aerosol organic fraction. Ensemble large-scale forcing data sets are derived from the ARM variational analysis, European Centre for Medium-Range Weather Forecasts, and a multiscale data assimilation system. The forcings are assessed through comparison of measured bulk atmospheric and cloud properties to those computed in "trial" large-eddy simulations, where more efficient run times are enabled through modest reductions in grid resolution and domain size compared to the full-sized LES grid. Simulations capture many of the general features observed, but the state-of-the-art forcings were limited at representing details of cloud onset, and tight gradients and high-resolution transients of importance. Methods for improving the initial conditions and forcings are discussed. The cases developed are available to the general modeling community for studying continental boundary clouds.

  2. RACORO Continental Boundary Layer Cloud Investigations: 1. Case Study Development and Ensemble Large-Scale Forcings

    Science.gov (United States)

    Vogelmann, Andrew M.; Fridlind, Ann M.; Toto, Tami; Endo, Satoshi; Lin, Wuyin; Wang, Jian; Feng, Sha; Zhang, Yunyan; Turner, David D.; Liu, Yangang; hide

    2015-01-01

    Observation-based modeling case studies of continental boundary layer clouds have been developed to study cloudy boundary layers, aerosol influences upon them, and their representation in cloud- and global-scale models. Three 60 h case study periods span the temporal evolution of cumulus, stratiform, and drizzling boundary layer cloud systems, representing mixed and transitional states rather than idealized or canonical cases. Based on in situ measurements from the Routine AAF (Atmospheric Radiation Measurement (ARM) Aerial Facility) CLOWD (Clouds with Low Optical Water Depth) Optical Radiative Observations (RACORO) field campaign and remote sensing observations, the cases are designed with a modular configuration to simplify use in large-eddy simulations (LES) and single-column models. Aircraft measurements of aerosol number size distribution are fit to lognormal functions for concise representation in models. Values of the aerosol hygroscopicity parameter, kappa, are derived from observations to be approximately 0.10, which are lower than the 0.3 typical over continents and suggestive of a large aerosol organic fraction. Ensemble large-scale forcing data sets are derived from the ARM variational analysis, European Centre for Medium-Range Weather Forecasts, and a multiscale data assimilation system. The forcings are assessed through comparison of measured bulk atmospheric and cloud properties to those computed in "trial" large-eddy simulations, where more efficient run times are enabled through modest reductions in grid resolution and domain size compared to the full-sized LES grid. Simulations capture many of the general features observed, but the state-of-the-art forcings were limited at representing details of cloud onset, and tight gradients and high-resolution transients of importance. Methods for improving the initial conditions and forcings are discussed. The cases developed are available to the general modeling community for studying continental boundary

  3. Study of vapour phase dynamics with nitrogen boiling in the field of centrifugal forces

    International Nuclear Information System (INIS)

    Levchenko, N.M.; Kolod'ko, I.M.

    1987-01-01

    The vapour phase dynamics during film boiling of liquid nitrogen on horizontal wire in the field of centrifugal forces has been studied experimentally in a wide range of overloads(1 ≤ η ≤ 375) and heat fluxes (q kp2 ≤ q ≤ 4q kpi ). The available data confirmed and the theoretical relationships suggested make it possible to calculate the hydrodynamic film boiling parameters (wave length, bubble departure diameter and frequency) for other liquids

  4. Thermometric titration in investigation of the formation of polyanions of molybdenum(VI), tungsten(VI), vanadium(V), and chromium (VI)-I: comparison of thermometric and potentiometric titration curves.

    Science.gov (United States)

    Kiba, N; Takeuchi, T

    1973-09-01

    A new twin-cell thermometric titrator has been devised and used for thermometric titration of solutions of sodium molybdate, sodium tungstate, sodium orthovanadate, ammonium metavanadate, and potassium chromate with perchloric acid. The thermometric titration curves were compared with corresponding pH-titration curves for elucidation of the reactions occurring in the titrations. Thermometric titrimetric methods have been developed for the determination of tungsten, vanadium and chromium.

  5. Self-titration by experienced e-cigarette users: blood nicotine delivery and subjective effects.

    Science.gov (United States)

    Dawkins, Lynne E; Kimber, Catherine F; Doig, Mira; Feyerabend, Colin; Corcoran, Olivia

    2016-08-01

    Self-titration is well documented in the tobacco literature. The extent to which e-cigarette users (vapers) self-titrate is unknown. This study explored the effects of high and low nicotine strength liquid on puffing topography, nicotine delivery and subjective effects in experienced vapers. Eleven experienced male vapers completed 60 min of ad libitum vaping under low (6 mg/mL) and high (24 mg/mL) nicotine liquid conditions in two separate sessions. Measurements included puffing topography (puff number, puff duration, volume of liquid consumed) and changes in plasma nicotine levels, craving, withdrawal symptoms, self-reported hit, satisfaction and adverse effects. Liquid consumption and puff number were higher and puff duration longer, in the low nicotine strength condition (all ps < 0.01). The mean difference in nicotine boost from baseline in the low condition was 8.59 (7.52) ng/mL, 16.99 (11.72) ng/mL and 22.03 (16.19) ng/mL at 10, 30 and 60 min, respectively. Corresponding values for the high condition were 33.77 (34.88) ng/mL, 35.48 (28.31) ng/mL and 43.57 (34.78) ng/mL (ps < 0.05). There were no statistically significant differences between conditions in self-reported craving, withdrawal symptoms, satisfaction, hit or adverse effects. Vapers engaged in compensatory puffing with lower nicotine strength liquid, doubling their consumption. Whilst compensatory puffing was sufficient to reduce craving and withdrawal discomfort, self-titration was incomplete with significantly higher plasma nicotine levels in the high condition.

  6. Novel strategy for generation and titration of recombinant adeno-associated virus vectors.

    Science.gov (United States)

    Shiau, Ai-Li; Liu, Pu-Ste; Wu, Chao-Liang

    2005-01-01

    Recombinant adeno-associated virus (rAAV) vectors have many advantages for gene therapeutic applications compared with other vector systems. Several methods that use plasmids or helper viruses have been reported for the generation of rAAV vectors. Unfortunately, the preparation of large-scale rAAV stocks is labor-intensive. Moreover, the biological titration of rAAV is still difficult, which may limit its preclinical and clinical applications. For this study, we developed a novel strategy to generate and biologically titrate rAAV vectors. A recombinant pseudorabies virus (PrV) with defects in its gD, gE, and thymidine kinase genes was engineered to express the AAV rep and cap genes, yielding PS virus, which served as a packaging and helper virus for the generation of rAAV vectors. PS virus was useful not only for generating high-titer rAAV vectors by cotransfection with an rAAV vector plasmid, but also for amplifying rAAV stocks. Notably, the biological titration of rAAV vectors was also feasible when cells were coinfected with rAAV and PS virus. Based on this strategy, we produced an rAAV that expresses prothymosin alpha (ProT). Expression of the ProT protein in vitro and in vivo mediated by rAAV/ProT gene transfer was detected by immunohistochemistry and a bioassay. Taken together, our results demonstrate that the PrV vector-based system is useful for generating rAAV vectors carrying various transgenes.

  7. A novel approach for high precision rapid potentiometric titrations: application to hydrazine assay.

    Science.gov (United States)

    Sahoo, P; Malathi, N; Ananthanarayanan, R; Praveen, K; Murali, N

    2011-11-01

    We propose a high precision rapid personal computer (PC) based potentiometric titration technique using a specially designed mini-cell to carry out redox titrations for assay of chemicals in quality control laboratories attached to industrial, R&D, and nuclear establishments. Using this technique a few microlitre of sample (50-100 μl) in a total volume of ~2 ml solution can be titrated and the waste generated after titration is extremely low comparing to that obtained from the conventional titration technique. The entire titration including online data acquisition followed by immediate offline analysis of data to get information about concentration of unknown sample is completed within a couple of minutes (about 2 min). This facility has been created using a new class of sensors, viz., pulsating sensors developed in-house. The basic concept in designing such instrument and the salient features of the titration device are presented in this paper. The performance of the titration facility was examined by conducting some of the high resolution redox titrations using dilute solutions--hydrazine against KIO(3) in HCl medium, Fe(II) against Ce(IV) and uranium using Davies-Gray method. The precision of titrations using this innovative approach lies between 0.048% and 1.0% relative standard deviation in different redox titrations. With the evolution of this rapid PC based titrator it was possible to develop a simple but high precision potentiometric titration technique for quick determination of hydrazine in nuclear fuel dissolver solution in the context of reprocessing of spent nuclear fuel in fast breeder reactors. © 2011 American Institute of Physics

  8. Major depression, fibromyalgia and labour force participation: A population-based cross-sectional study

    Directory of Open Access Journals (Sweden)

    Patten Scott B

    2006-01-01

    Full Text Available Abstract Background Previous studies have documented an elevated frequency of depressive symptoms and disorders in fibromyalgia, but have not examined the association between this comorbidity and occupational status. The purpose of this study was to describe these epidemiological associations using a national probability sample. Methods Data from iteration 1.1 of the Canadian Community Health Survey (CCHS were used. The CCHS 1.1 was a large-scale national general health survey. The prevalence of major depression in subjects reporting that they had been diagnosed with fibromyalgia by a health professional was estimated, and then stratified by demographic variables. Logistic regression models predicting labour force participation were also examined. Results The annual prevalence of major depression was three times higher in subjects with fibromyalgia: 22.2% (95% CI 19.4 – 24.9, than in those without this condition: 7.2% (95% CI 7.0 – 7.4. The association persisted despite stratification for demographic variables. Logistic regression models predicting labour force participation indicated that both conditions had an independent (negative effect on labour force participation. Conclusion Fibromyalgia and major depression commonly co-occur and may be related to each other at a pathophysiological level. However, each syndrome is independently and negatively associated with labour force participation. A strength of this study is that it was conducted in a large probability sample from the general population. The main limitations are its cross-sectional nature, and its reliance on self-reported diagnoses of fibromyalgia.

  9. Semi-automated potentiometric titration method for uranium characterization.

    Science.gov (United States)

    Cristiano, B F G; Delgado, J U; da Silva, J W S; de Barros, P D; de Araújo, R M S; Lopes, R T

    2012-07-01

    The manual version of the potentiometric titration method has been used for certification and characterization of uranium compounds. In order to reduce the analysis time and the influence of the analyst, a semi-automatic version of the method was developed in the Brazilian Nuclear Energy Commission. The method was applied with traceability assured by using a potassium dichromate primary standard. The combined standard uncertainty in determining the total concentration of uranium was around 0.01%, which is suitable for uranium characterization. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Lower limb force, power and performance in skateboarding: an exploratory study

    Directory of Open Access Journals (Sweden)

    Cláudia Tarragô Candotti

    2012-09-01

    Full Text Available The purpose of this study was to identify the relationship between the height reached when performing the Ollie maneuver and the muscle force and power of the lower limbs required by beginner level skateboarders. Ten practitioners of Street category, with at least two years experience and who participate in competitions in Beginner, Amateur II or Amateur I categories were submitted to three tests: (1 maximal voluntary contraction of the knee and hip extensor muscles; (2 vertical jump tests, Counter Movement Jump (CJ and Squat Jump (SJ; and (3 the maximum height achieved during the Ollie maneuver. The results demonstrate that the variance of the Ollie maneuver (p<0.05 is explained by the power estimated with the CJ (76.3%; and the maximal force of the knee extensor muscle (50.6%. These results suggest that the variable power is strongly associated with the performance of the Ollie maneuver.

  11. Patient emotions and perceptions of antiepileptic drug changes and titration during treatment for epilepsy.

    Science.gov (United States)

    Fishman, Jesse; Cohen, Greg; Josephson, Colin; Collier, Ann Marie; Bharatham, Srikanth; Zhang, Ying; Wild, Imane

    2017-04-01

    To investigate the impact of antiepileptic drug (AED) change and dose titration on the emotional well-being of patients with epilepsy. Members of an online epilepsy community were invited to voluntarily participate in an online survey. The cross-sectional anonymous survey consisted of 31 multiple choice questions balanced in terms of variety and positivity/negativity of emotions concerning participants' most recent AED change. To substantiate survey results, spontaneous comments from epilepsy-related online forums and social media websites that mentioned participants' experiences with AED medication changes (termed passive listening statements) were analyzed and categorized by theme. All 345 survey participants (270 [78.3%] female; 172 [49.9%] were 26-45years old) self-reported an epilepsy/seizure diagnosis and were currently taking seizure medication; 263 (76.2%) were taking ≥2 AEDs and 301 (87.2%) had ≥1 seizure in the previous 18months. All participants reported a medication change within the previous 12months (dose increased [153 participants (44.3%)], medication added [105 (30.4%)], dose decreased [49 (14.2%)], medication removed [38 (11.0%)]). Improving seizure control (247 [71.6%]) and adverse events (109 [31.6%]) were the most common reasons for medication change. Primary emotions most associated (≥10% of participants) with an AED regimen change were (before medication change; during/after medication change) hopefulness (50 [14.5%]; 43 [12.5%]), uncertainty (50 [14.5%]; 69 [20.0%]), and anxiety (35 [10.1%]; 45 [13.0%]), and were largely due to concerns whether the change would work (212/345 [61.4%]; 180/345 [52.2%]). In the text analysis segment aimed at validating the survey, 230 participants' passive listening statements about medication titration were analyzed; additional seizure activity during dose titration (93 [40.4%]), adverse events during titration (71 [30.9%]), higher medication dosages (33 [14.3%]), and drug costs (25 [10.9%]) were the

  12. Atomic force microscopic study of the influence of physical stresses on Saccharomyces cerevisiae and Schizosaccharomyces pombe.

    Science.gov (United States)

    Adya, Ashok K; Canetta, Elisabetta; Walker, Graeme M

    2006-01-01

    Morphological changes in the cell surfaces of the budding yeast Saccharomyces cerevisiae (strain NCYC 1681), and the fission yeast Schizosaccharomyces pombe (strain DVPB 1354), in response to thermal and osmotic stresses, were investigated using an atomic force microscope. With this microscope imaging, together with measurements of culture viability and cell size, it was possible to relate topological changes of the cell surface at nanoscale with cellular stress physiology. As expected, when the yeasts were exposed to thermostress or osmostress, their viability together with the mean cell volume decreased in conjunction with the increase in thermal or osmotic shock. Nevertheless, the viability of cells stressed for up to 1 h remained relatively high. For example, viabilities were >50% and >90% for the thermostressed, and >60% and >70% for the osmostressed S. cerevisiae and Schiz. pombe, respectively. Mean cell volume measurements, and bearing and roughness analyses of atomic force microscope images of stressed yeasts indicate that Schiz. pombe may be more resistant to physical stresses than S. cerevisiae. Overall, this study has highlighted the usefulness of atomic force microscope in studies of yeast stress physiology.

  13. Comparison of vertical ground reaction forces during overground and treadmill running. A validation study

    NARCIS (Netherlands)

    Kluitenberg, Bas; Bredeweg, Steef W.; Zijlstra, Sjouke; Zijlstra, Wiebren; Buist, Ida

    2012-01-01

    Background: One major drawback in measuring ground-reaction forces during running is that it is time consuming to get representative ground-reaction force (GRF) values with a traditional force platform. An instrumented force measuring treadmill can overcome the shortcomings inherent to overground

  14. A Study of the Confinement Induced Sponge to Lamellar Phase Transformation by Direct Force Measurement

    International Nuclear Information System (INIS)

    Antelmi, David

    1996-10-01

    The interactions between two macroscopic walls immersed in an isotropic symmetric sponge phase (L_3) at different volume fractions, Φ, were studied with a surface force apparatus. The purpose of these experiments was to investigate the behaviour of the sponge phase when confined between two smooth rigid surfaces. Particular attention was given to investigating this behaviour as the bulk transition to the lamellar phase (L_α) was approached. At temperatures far from the L_3/L_α bulk transition temperature, the force-distance profile showed weak oscillations with a periodicity approximately equal to twice the characteristic length, ξ, measured for the sponge phase from small angle x-ray scattering. Furthermore, the oscillations were superimposed on an exponential attractive background that decayed with an order parameter correlation length of 2-3 times ξ The attractive background was explained by the enhancement of the sponge order in the vicinity of the rigid walls. The structural oscillations observed in the force-distance profile, although not completely understood, were discussed in terms of the packing of sponge cells (cell size ξ). The significance of the observed periodicity (2ξ) may indicate the importance of the symmetric nature of the sponge phase. By moving pairs of cells in response to an applied strain, the symmetry of the sponge structure is protected. As the temperature increased towards the L_3/L_α bulk transition temperature, an abrupt change in the force-distance profile was observed at a threshold separation labelled D*_i_n. A different force regime was observed for separations below D*_i_n which oscillated with a periodicity that was twice the reticular spacing, d, for a L_α phase of similar Φ. The force oscillations were superimposed on an attractive background that was almost linear. These observations were consistent with a first order phase transition from the sponge phase to the lamellar phase, induced by the confinement, where the

  15. Integration of the Forced-Choice Questionnaire and the Likert Scale: A Simulation Study

    Directory of Open Access Journals (Sweden)

    Yue Xiao

    2017-05-01

    Full Text Available The Thurstonian item response theory (IRT model allows estimating the latent trait scores of respondents directly through their responses in forced-choice questionnaires. It solves a part of problems brought by the traditional scoring methods of this kind of questionnaires. However, the forced-choice designs may still have their own limitations: The model may encounter underidentification and non-convergence and the test may show low test reliability in simple test designs (e.g., test designs with only a small number of traits measured or short length. To overcome these weaknesses, the present study applied the Thurstonian IRT model and the Graded Response Model to a different test format that comprises both forced-choice blocks and Likert-type items. And the Likert items should have low social desirability. A Monte Carlo simulation study is used to investigate how the mixed response format performs under various conditions. Four factors are considered: the number of traits, test length, the percentage of Likert items, and the proportion of pairs composed of items keyed in opposite directions. Results reveal that the mixed response format can be superior to the forced-choice format, especially in simple designs where the latter performs poorly. Besides the number of Likert items needed is small. One point to note is that researchers need to choose Likert items cautiously as Likert items may bring other response biases to the test. Discussion and suggestions are given to construct personality tests that can resist faking as much as possible and have acceptable reliability.

  16. Cross-sectional study of neck pain and cervical sagittal alignment in air force pilots.

    Science.gov (United States)

    Moon, Bong Ju; Choi, Kyong Ho; Yun, Chul; Ha, Yoon

    2015-05-01

    There is a high prevalence of neck pain in air force pilots; however, the causes are not clear and are considered work-related. Kyphotic changes in the cervical spine have been known to cause neck pain. In this study, we investigated the association between neck pain and cervical kyphosis in air force pilots. This is a cross-sectional study of 63 Republic of South Korea Air Force pilots. We examined the C2-7 absolute rotation angle (ARA) using the posterior tangent method and other radiologic parameters on whole spine lateral radiographs. We divided the participants into a neck pain group (N = 32) and no neck pain group (N = 31), and subsequently analyzed the difference in radiographic parameters and clinical data between the two groups. There were no significant differences found in age, body mass index, total flight time, or aerobic or anaerobic exercise between the neck pain and control groups. The fighter pilots had higher 1-yr prevalence of neck pain than nonfighter pilots (84.4% vs. 15.6%). The lower C2-7 ARA (OR = 0.91, 95% CI 0.846, 0.979) and fighter type aircrafts (OR = 3.93, 95% CI 1.104, 13.989) were associated with neck pain. Fighter pilots experienced neck pain more frequently than the nonfighter pilots. Those fighter pilots suffering from neck pain were shown to have more kyphotic changes in the cervical spine than control pilots through evaluation of whole spine lateral radiographs using the posterior tangent method. These key findings suggest that the forces involved in flying a fighter type aircraft may affect cervical alignment and neck pain.

  17. Practical Focus on American Diabetes Association/European Association for the Study of Diabetes Consensus Algorithm in Patients with Type 2 Diabetes Mellitus: Timely Insulin Initiation and Titration (Iran-AFECT).

    Science.gov (United States)

    Khamseh, Mohammad Ebrahim; Yousefzadeh, Gholamreza; Banazadeh, Zahra; Ghareh, Sahar

    2017-02-01

    The aim of this study was to evaluate the safety and effectiveness of insulin glargine in a large population from a variety of clinical care in Iranian people with type 2 diabetes mellitus (T2DM) and to measure the percentage of patients achieving glycosylated hemoglobin (HbA1c) Diabetes Association

  18. A Basic Study on Countermeasure Against Aerodynamic Force Acting on Train Running Inside Tunnel Using Air Blowing

    Science.gov (United States)

    Suzuki, Masahiro; Nakade, Koji

    A basic study of flow controls using air blowing was conducted to reduce unsteady aerodynamic force acting on trains running in tunnels. An air blowing device is installed around a model car in a wind tunnel. Steady and periodic blowings are examined utilizing electromagnetic valves. Pressure fluctuations are measured and the aerodynamic force acting on the car is estimated. The results are as follows: a) The air blowing allows reducing the unsteady aerodynamic force. b) It is effective to blow air horizontally at the lower side of the car facing the tunnel wall. c) The reduction rate of the unsteady aerodynamic force relates to the rate of momentum of the blowing to that of the uniform flow. d) The periodic blowing with the same frequency as the unsteady aerodynamic force reduces the aerodynamic force in a manner similar to the steady blowing.

  19. Free Software Development. 3. Numerical Description of Soft Acid with Soft Base Titration

    Directory of Open Access Journals (Sweden)

    Lorentz JÄNTSCHI

    2002-12-01

    Full Text Available The analytical methods of qualitative and quantitative determination of ions in solutions are very flexible to automation. The present work is focus on modeling the process of titration and presents a numerical simulation of acid-base titration. A PHP program to compute all iterations in titration process that solves a 3th rank equation to find value of pH for was built and is available through http internet protocol at the address: http://vl.academicdirect.org/molecular_dynamics/ab_titrations/v1.1/ The method allows expressing the value of pH in any point of titration process and permits to observe the equivalence point of titration.

  20. [A double antibody sandwich ELISA based assay for titration of severe fever with thrombocytopenia syndrome virus].

    Science.gov (United States)

    Liu, Lin; Zhang, Quan-Fu; Li, Chuan; Li, Jian-Dong; Jiang, Xiao-Lin; Zhang, Fu-Shun; Wu, Wei; Liang, Mi-Fang; Li, De-Xin

    2013-06-01

    To develop an assay for titration of severe fever with thrombocytopenia syndrome virus (SFTSV) based on double antibody sandwich ELISA. A double antibody sandwich ELISA was developed for detection of SFTSV based on SFTSV nucleocapsid (N) protein specific poly- and monoclonal antibodies, procedures were optimized and evaluated. This ELISA based titration assay was compared with fluorescence assasy and plaque assay based titration method. The results suggested that the titers obtained by ELISA based method are consistent with those obtained by IFA based method (R = 0.999) and the plaque assay titration method (R = 0.949). The novel ELISA based titration method with high sensitivity and specificity is easy to manage and perform, and can overcome the subjectivity associated with result determination of the fluorescence assay and plaque assay based methods. The novel ELISA based titration method can also be applied to high throughput detection.