  1. MIBI-{sup 99m}Tc mammary scintigraphy; Centellografia mamaria con MIBI-{sup 99m}Tc

    Energy Technology Data Exchange (ETDEWEB)

    Mayosky, Maria C; Parma, Elvira P; Armesto, Amparo M; Zarlenga, Ana C [Instituto de Oncologia Angel H. Roffo, Buenos Aires (Argentina). Centro Oncologico de Medicina Nuclear; Cresta, Carlos; Azar, Maria E; Noblia, Cristina [Instituto de Oncologia Angel H. Roffo, Buenos Aires (Argentina). Servicio de Mastologia

    1999-07-01

    121 patients suspected of breast cancer were studied with MIBI-{sup 99m}Tc to evaluate the suitability of the mammary scintigraphy in patients with doubtful cancer diagnosis.The results show 93 % sensitivity and 95 % specificity and indicate the usefulness of this procedure to increase the accuracy of the diagnosis.

  2. Labelled Preformed liposomes with 99MTC-DTPA, 99 MTC-ECD, 99MTC-MDP and 99MTC-MIBI : Labelling procedures and stability studies

    International Nuclear Information System (INIS)

    Savio, E.O.; Teran, M.A.; Vales, M.E.; Frier, M.

    2004-01-01

    Liposomes labelled with gamma e miters like 99mTc, can be used for scintigraphic imaging to non-invasively track and quantify the distribution of liposomes in the body. In vitro studies were done to choose a suitable radiopharmaceutical (RF) to be attached to performed liposomes. 99mTc-Complexes (DTPA, ECD, MDP, MIBI) were used to label collagen liposomes. Commercial kits were labelled with 99mTc04-(TechnoNuclear). Quality controls of the RF were performed. Collagen liposomes suspended in saline 0.9% were incubated at 4.25.37 and 60 for 30 min. Efficiency of the labelling procedure was determined by gel filtration using Sephadex G25 (Pharmacia) and NaC10.9%. Samples of 100mL (74MBq), were seeded and fractions of 0.5mL were colleted and measured in an ionisation chamber (Capintec CRC). Stability of the labelled liposomes was assessed incubating 0.5mL, of the suspension with 1mL of human serum during 30 min at 37 . Dialysis was performed using dialysis bags of 64 K pore size and NaCI 0.9% at room temperature. Samples of the saline bath were collected at 30.60 and 90 min. and measured in a solid scintillation counter Ortec.Liposomes labelled with 99mTc-DTPA and 99mTcMIBI showed a labelling efficiency of 80%; liposomes incubated with 99mTc-MDP were labelled in a 50% and 99mTc-ECD did not bind to liposomes in the conditions of study. Incubation of labelled liposomes with human serum showed 50% of strong binding to the plasmatic proteins for 99mTc-DTPA but low values (5%) for the other specimens. Labelled liposomes were achieved, with different RF, showing a suitable in vitro stability to perform in vivo studies

  3. Comparison of 99Tcm(V)-DMSA and 99Tcm-MIBI scintigraphy in medullary thyroid carcinoma

    International Nuclear Information System (INIS)

    Deng Bo; Xiao Huan; Chen Xiaofeng; Chen Huaming

    2004-01-01

    SPECT scintigraphy is used in 62 patients with medullary thyroid carcinoma (MTC), which are divided into two groups: 32 patients by 99 Tc m (V)-DMSA and 30 patients by 99 Tc m -MIBI. The qualitative analysis and half quantitative analysis are performed to the early and delayed images. Comparing the results with two groups, there is no difference in the masculine rate of MTC primary focus, but the results of 99 Tc m (V)-DMSA scintigraphy is obviously larger than 99 Tc m -MIBI by half quantitative analysis. The results show that the 99 Tc m (V)-DMSA scintigraphy is more predominant than the 99 Tc m -(V)-DMSA scintigraphy may be superior to 99 Tc m -MIBI in MTC primary focus and metastasis focus before surging for MTC patients. (authors)

  4. {sup 99m}Tc sestamibi imaging. Can it be a useful substitute for hepatobiliary scintigraphy in infantile jaundice?

    Energy Technology Data Exchange (ETDEWEB)

    Sadeghi, R.; Kakhki, V.R.D.; Zakavi, R. [Mashhad Univ. of Medical Sciences (Iran). Nuclear Medicine Dept.; Kianifar, H.R. [Mashhad Univ. of Medical Sciences (Iran). Paediatric Dept.; Ansari, K. [Tehran Univ. of Medical Sciences (Iran). Nuclear Medicine Dept.

    2009-07-01

    Hepatobiliary scintigraphy is an integral part in the diagnostic work-up of the neonatal cholestasis syndrome. However, less than optimal specificity is its major disadvantage. Differentiation between biliary atresia and neonatal hepatitis is nearly impossible in some cases with poor hepatocellular function. {sup 99m}Tc sestamibi (MIBI) is a cationic lipophilic agent which is a substrate of P-glycoprotein. This glycoprotein is normally expressed in biliary canalicular surfaces of hepatocytes. This property provides a hepatic excretory mechanism which is different from bilirubin excretion. In this study we evaluated the value of {sup 99m}Tc MIBI in differential diagnosis of neonatal cholestasis. 20 infants with a mean age of 2.41 months (range, 0.1-5 months) were included in the study. Ten infants turned out to have extrahepatic biliary atresia and the other ten had neonatal hepatitis. Hepatobiliary (with {sup 99m}Tc BrIDA) and {sup 99m}Tc MIBI scintigraphy were performed for all the patients. {sup 99m}Tc MIBI scintigraphy has shown bowel activity in all patients, including the patients with biliary atresia. Hepatobiliary scintigraphy revealed bowel activity only in five patients with neonatal hepatitis. Bowel visualization with {sup 99m}Tc MIBI may be seen in patients with biliary atresia and {sup 99m}Tc MIBI has limited value in differential diagnosis of neonatal cholestasis. (orig.)

  5. Paradoxical motion of interventricular septum on Tc-99m MIBI gated SPECT study

    International Nuclear Information System (INIS)

    Ergun, E.L.; Erbas, B.; Beylergil, V.; Demirturk, O.S.; Pasaoglu, I.

    2004-01-01

    After uncomplicated cardiac surgery, abnormal motion of the interventricular septum is frequently observed. The interventricular septum has often been found to display dyskinetic, or paradoxical motion by echocardiographic studies. This study was undertaken to describe instances of paradoxical motion of interventricular septum on Tc-99m MIBI gated SPECT studies in patients after coronary artery by pass graft surgery. Tc-99m MIBI gated SPECT in conjunction with stress myocardial perfusion SPECT was performed in 18 patients who had history of cardiac bypass graft surgery. Paradoxical motion of the interventricular septum was defined visually from Tc-99m MIBI gated SPECT. Perfusion of the interventricular septum was examined from myocardial perfusion images in the same study. Paradoxical motion of the interventricular septum was observed in 4 patients (22%). The interventricular septum was normally perfused in all patients. It was concluded that paradoxical motion of the interventricular septum in patients who had a history of cardiac by-pass graft surgery is not an uncommon finding and it can be observed with gated SPECT. The exact mechanism of this phenomenon is not well-known. A normal perfusion in interventricular wall helps to discriminate this situation from a real abnormality. (author)

  6. Early myocardial damage assessment in dystrophinopathies using 99Tcm-MIBI gated myocardial perfusion imaging

    Directory of Open Access Journals (Sweden)

    Zhang L

    2015-12-01

    Full Text Available Li Zhang,1,* Zhe Liu,2,* Ke-You Hu,3 Qing-Bao Tian,3 Ling-Ge Wei,4 Zhe Zhao,5 Hong-Rui Shen,5 Jing Hu5 1Department of Cardiovascular Disorders, 2Department of Geriatrics, The Third Hospital of Hebei Medical University, 3The Public Health Department, Hebei Medical University, 4Department of Nuclear Medicine, 5Department of Neuromuscular Disorders, The Third Hospital of Hebei Medical University, Shijiazhuang, People’s Republic of China *Li Zhang and Zhe Liu are first coauthors of this paper Background: Early detection of muscular dystrophy (MD-associated cardiomyopathy is important because early medical treatment may slow cardiac remodeling and attenuate symptoms of cardiac dysfunction; however, no sensitive and standard diagnostic method for MD at an earlier stage has been well-recognized. Thus, the aim of this study was to test the early diagnostic value of technetium 99m-methoxyisobutylisonitrile (99Tcm-MIBI gated myocardial perfusion imaging (G-MPI for MD.Methods and results: Ninety-one patients underwent 99Tcm-MIBI G-MPI examinations when they were diagnosed with Duchenne muscular dystrophy (DMD (n=77 or Becker muscular dystrophy (BMD; n=14. 99Tcm-MIBI G-MPI examinations were repeated in 43 DMD patients who received steroid treatments for 2 years as a follow-up examination. Myocardial defects were observed in nearly every segment of the left ventricular wall in both DMD and BMD patients compared with controls, especially in the inferior walls and the apices by using 99Tcm-MIBI G-MPI. Cardiac wall movement impairment significantly correlated with age in the DMD and BMD groups (rs=0.534 [P<0.05] and rs=0.784 [P<0.05], respectively. Intermittent intravenous doses of glucocorticoids and continuation with oral steroid treatments significantly improved myocardial function in DMD patients (P<0.05, but not in BMD patients.Conclusion: 99Tcm-MIBI G-MPI is a sensitive and safe approach for early evaluation of cardiomyopathy in patients with DMD or BMD

  7. MIBI-99mTc mammary scintigraphy

    International Nuclear Information System (INIS)

    Mayosky, Maria C.; Parma, Elvira P.; Armesto, Amparo M.; Zarlenga, Ana C.; Cresta, Carlos; Azar, Maria E.; Noblia, Cristina

    1999-01-01

    121 patients suspected of breast cancer were studied with MIBI- 99m Tc to evaluate the suitability of the mammary scintigraphy in patients with doubtful cancer diagnosis.The results show 93 % sensitivity and 95 % specificity and indicate the usefulness of this procedure to increase the accuracy of the diagnosis

  8. 99M-TC MIBI-an indicator of active disease in multiple myeloma

    International Nuclear Information System (INIS)

    Raluca Mititelu; Serban Ghita; Catalin Mazilu; George Marinescu

    2004-01-01

    Purpose: to evaluate the role of 99mTc-MIBI in the assessment of bone marrow involvement in patients with multiple myeloma and to demonstrate how different patterns of 99mTc-MIBI uptake are reflecting the activity of the disease. Material and method: 27 patients with documented MM were studied, 14M, 13 F, median age 62 years, range 31 - 78. 7 MPI (myocardial perfusion imaging) patients served as controle. Diagnosis and staging of the disease were based on standard criteria: 5 patients in stage I, 7 in stage II, 15 in stage III. The disease activity was determined by clinical and biological assessment and the aspect of bone marrow biopsy. 17 patients had active disease (2 patients in stage I, 4 in stage II, 11 in stage III), 10 patients had not' clinical and biological criteria of active disease. All patients included in the group of active disease underwent radiological examination, 99mTc-MDP whole-body scan and 99mTc-MIBI whole-body scan. MRI was performed in 5 patients with active disease (2 in stage I, 1 in stage II, 2 in stage lib - for evaluation of spine involvement. In the other group (patients with clinical and biological criteria of non-active disease), due to high cost of investigations, we performed whole-body 99mTc-MIBI scan, as the oncologist referred us the patient for monitoring therapeutic response. Whole-body 99mTc-MIBI scans were obtained 20 rain after iv injection of 740 MBq 99mTc-MIBI, in anterior and posterior views, with a dual-head gamma camera Philips -Axis. Results: In the group of patients with active disease (17 patients) we found three different patterns of pathologic 99mTc-MIBI uptake: focal uptake in different sites in 9 patients, diffuse uptake in 4, both focal and diffuse uptake in 3; no pathologic uptake was seen in 1 patient (probably due to overexpression of Pglycoprotein). In the other group, with non-active disease criteria (10 patients), we found normal aspect of 99mTc-MIBI uptake in 8 patients; 2 patients had diffuse increased

  9. Internal Dosimetry and the pharmacokinetic of the Cuban Kit of Methoxy-Isobutyl-Isonitrile (MIBI) marked with 99mTc

    International Nuclear Information System (INIS)

    Torres, L.A.; Pereztol, O.; Rodriguez, J.L.; Alvarez, I.; Fraxedas, R.; Mesa, G.; Rodriguez, R.

    1998-01-01

    The objective of the present work consisted on evaluating the Internal Dosimetry and the pharmacokinetic of the Cuban Kit of Methoxy-Isobutyl-Isonitrile (MIBI) marked with 99mTc. In the dosimetry studies and biodistribution five healthy volunteers were included and in the pharmacokinetic studies five patients were included with less than 5% of probability of suffering illness of artery coronary

  10. The role of Technetium99m-MIBI in the follow-up of differentiated thyroid carcinoma

    International Nuclear Information System (INIS)

    Machado, L.S.; Corbo, R.; Pedras, D.S.V.; Anttonuccia, J.B.

    2004-01-01

    Full text: Technetium-99m-methoxyisobutylisonitrile (99mTc-MIBI) is being used as a tumor-seeking agent over the last few years. We evaluated the role of 99mTc-MIBI whole body scan (WBS) in localizing metastatic lesions in patients with thyroid cancer and compared the results with 131I scan and serum thyroglobulin (Tg) levels. Eighty nine patients of differentiated thyroid cancer subjected to thyroidectomy were enrolled for the study. Early (20 minutes) and delayed (6 and 24 hours) whole body images were obtained after injecting 99mTc-MIBI. Tg measurements were obtained during thyroid hormone replacement and 4 weeks after hormone discontinuation. 131I scans were performed after low diagnostic or high ablative/therapeutic dose. These methods were used as standard to evaluate the presence of residual or metastatic thyroid cancer. The patients with positive 99mTc-MIBI scan but negative 131I scan underwent chest x-ray, computed tomography (CT) or magnetic resonance imaging (MRI). 34 of the total 89 patients were found to be negative on 131I scan. 23 of these 34 patients had negative 99mTc-MIBI WBS and 11 patients were positive for abnormal MIBI uptake (specificity: 67.6%). Twenty-two patients had both 99mTc-MIBI WBS and 131I scan positive. Eleven patients had 131I scan negative and 99mTc-MIBI WBS positive; seven of those proved to be true positive. From the findings of our study, it may be concluded that although 99mTc-MIBI has low sensitivity for detection of tumor recurrence, it definitely has a role as a supplementary tool to thyroglobulin measurements and 131I scans. (author)

  11. Reproducibility of the assessment of myocardial function using gated Tc-99m-MIBI SPECT and quantitative software

    International Nuclear Information System (INIS)

    Lee, Dong Soo; Cheon, Gi Jeong; Ahn, Ji Young; Jeong, Joon Ki; Lee, Myung Chul

    1998-01-01

    We investigated reproducibility of the quantification of left ventricular volume and ejection fraction, and grading of myocardial wall motion and systolic thickening when we used gated myocardial SPECT and Cedars quantification software. We performed gated myocardial SPECT in 33 consecutive patients twice in the same position after Tc-99m-MIBI SPECT. We used 16 frames per cycle for the gating of sequential Tc-99m-MIBI SPECT. After reconstruction, we used Cedars quantitative gated SPECT and calculated ventricular volume and ejection fraction (EF). Wall motion was graded using 5 point score. Wall thickening was graded using 4 point score. Coefficient of variation for re-examination of volume and fraction were calculated. Kappa values (k-value) for assessing reproducibility of wall motion or wall thickening were calculated. Enddiastolic volumes (EDV) ranged from 58 ml to 248 ml (122 ml +/-42 ml), endsystolic volumes (ESV) from 20 ml to 174 ml (65 ml+/-39 ml), and EF from 20% to 68% (51%+/-14%). Geometric mean of standard deviations of 33 patients was 5.0 ml for EDV, 3.9 ml for ESV and 1.9% for EF. Their average differences were not different from zero (p>0.05). k-value for wall motion using 2 consecutive images was 0.76 (confidence interval: 0.71-0.81). k-value was 0.87 (confidence interval: 0.83-0.90) for assessment of wall thickening. We concluded that quantification of functional indices, assessment of wall motion and wall thickening using gated Tc-99m MIBI SPECT was reproducible and we could use this method for the evaluation of short-acting drug effect

  12. Preoperative radiological diagnosis by 99mTc·MIBI-99mTc subtraction scintigraphy for primary hyperparathyroidism

    International Nuclear Information System (INIS)

    Inouye, Takahiro; Tomita, Toshiki; Shinden, Seiichi; Takagi, Hitoshi; Kano, Shigeru.

    1996-01-01

    Preoperative radiological diagnosis constitutes the most important factor for the surgical treatment of hyperparathyroidism. In this regard, MRI is useful for detecting the abnormal parathyroid, but it is often difficult to localize it using MRI only. It is thus necessary to combine this procedure with excellent subtraction scintigraphy. We performed both 201 Tl- 99m Tc and 99m Tc·MIBI- 99m Tc subtraction scintigraphy in seven patients with primary hyperparathyroidism and compared them the radiological results. Five patients presented parathyroid adenomas and the rest hypertrophy of the parathyroid. We could detect the abnormal parathyroid in four patients (57.1%) by 201 Tl- 99m Tc subtraction scintigraphy and in six patients (85.7%) by 99m Tc·MIBI- 99m Tc subtraction scintigraphy. We therefore believe that 99m Tc·MIBI- 99m Tc subtraction scintigraphy will become an essential examination for primary hyperparathyroidism rather than the presently employed 201 Tl- 99m Tc subtraction scintigraphy. (author)

  13. Parathyroid hormone measurement and 99Tcm-MIBI imaging for hyperparathyroidism diagnosis

    International Nuclear Information System (INIS)

    Zhao Yunyun; Wang Qian; Li Yuan; Yue Minggang; Li Hebei

    2011-01-01

    Objective: To evaluate 99 Tc m -MIBI imaging in patients with hyperparathyroidism and its correlation with serum intact PTH level. Methods: Seventy patients with suspicious hyperparathyroidism underwent 99 Tc m -MIBI imaging and serum intact PTH measurement. Abnormal increased uptake lesion appeared at early phase and even more clearly at delayed phase was considered as the positive by 99 Tc m -MIBI imaging. A cut-off value of PTH >88 ng/L was taken as the criteria for hyperparathyroidism diagnosis. The diagnostic efficacy of 99 Tc m -MIBI imaging combined with serum PTH measurement was assessed according to post-surgical histopathology or clinical follow-up. For those operated patients, Pearson correlation coefficient between serum PTH and the gland volume was calculated. Results: Hyperparathyroidism was confirmed in 38 patients by histopathology (n=36) or follow-up (n=2). The overall diagnostic accuracy of 99 Tc m -MIBI imaging was 90.0% (63/70), in which the accuracy was 80.0% (12/15) for patients with normal serum PTH and 92.7% (51/55) for those with elevated serum PTH. False positive 99 Tc m -MIBI imaging were found in 3 patients with normal serum PTH. The diagnostic accuracy of abnormally high serum PTH combined with 99 Tc m -MIBI imaging was 94.3% (66/70). There was a positive correlation between serum PTH level and the volume of pathologic parathyroid glands (r=0.782, P<0.001). Conclusions: Serum PTH measurement may help to improve the diagnostic accuracy of 99 Tc m -MIBI imaging in patients with hyperparathyroidism. (authors)

  14. Comparison of thallium-201, Tc-99m MIBI and I-131 scan in the follow-up assessment after I-131 ablative therapy in differentiated thyroid cancer

    International Nuclear Information System (INIS)

    Kwon, Jae Sung; Lee, Sung Keun; Kim, Doe Min; Park, Sae Jong; Jang, Kyong Sun; Kim, Eun Sil; Kim, Chong Soon

    1999-01-01

    We conducted a comparative study to evaluate the diagnostic values of Tl-201, Tc-99m MIBI and I-131 scans in the follow-up assessment after ablative I-131 therapy in differentiated thyroid cancer. The study population consisted of 20 patients who underwent surgical removal of thyroid cancer and ablative radioactive iodine therapy, and followed by one or more times of I-131 retreatment (33 cases). In all patients, Tl-201, Tc-99m MIBI, diagnostic and therapeutic I-131 scans were performed and the results were analyzed retrospectively. Also serum thyroglobulin levels were measured in all patients. The final diagnosis of recurrent or metastatic thyroid cancer was determined by clinical, biochemical, radiologic and/or biopsy findings. Positive rates (PR) of Tc-99m MIBI, Tl-201, diagnostic and therapeutic I-131 scans in detecting malignant thyroid tissue lesions were 70% (19/27), 54% (15/28), 35% (17/48) and 63% (30/48), respectively. The PR in the group of 20 cases (28 lesions) who underwent concomitant Tl-201 and I-131 scans were in the order of therapeutic 131 scan 71%, Tl-201 scan 54% and diagnostic I-131 scan 36%. There was no statistically significant difference between Tl-201 and diagnostic I-131 scans (p>0.05). In the group of 20 cases (27 lesions) who underwent concomitant Tc-99m MIBI and I-131 scans, the PR were in the order of Tc-99m MIBI scan 70%, I-131 therapeutic scan 52% and I-131 diagnostic scan 33%. The PR of Tc-99m MIBI was significantly higher than that of diagnostic I-131 scan (p<0.05). Tc-99m MIBI scan is superior to diagnostic I-131 scan in detecting recurrent or metastatic thyroid cancer following ablation therapy in patients with differentiated thyroid cancer. Tl-201 scan did not showed significantly higher positive rate than diagnostic I-131 scan. Instead of diagnostic I-131 scan before the I-131 retreatment, Tc-99m MIBI scan without discontinuing thyroid hormone replacement would be a prudent and effective approach in the management of these

  15. The value of regional wall motion abnormalities on 99Tcm-MIBI gated cardiac SPECT in predicting angiographic stenoses of coronary artery

    International Nuclear Information System (INIS)

    Li Dianfu; Huang Jun; Zhu Tiebing; Wang Liansheng; Yang Zhijian; Feng Jianlin; Li Jianhua; Chen Jianwei; Chang Guojun

    2004-01-01

    Objective: To determine the magnitude of angiographic stenoses of coronary artery in reversible regional wall motion abnormalities (RWMA) present in exercise stress 99 Tc m -methoxyisobutylisonitrile (MIBI) gated SPECT myocardial perfusion imaging (MPI). Methods: One hundred and sixteen patients undergoing coronary angiography two weeks before and after the exercise stress 99 Tc m -MIBI gated SPECT MPI. Images were acquired 15 to 20 min after stress. A five grades and twenty segments marking system was introduced to assess the RWMA and thickening of left ventricles. Results: The sensitivity of reversible RWMA for detecting ≥75% angiographic stenoses was 65%, with a specificity of 97%. Reversible RWMA has a high positive predictive value (98%) for stratification between severe angiographic stenoses of 75% and non-severe stenoses (less than 75%). Multivariate analysis showed that the post-stress wall motion (SSSWM), exercise wall motion differentiation value (SDSWM) and summed stress score (SSS) were the independent risk factor of coronary artery jeopardy score. Conclusions: Reversible RWMA, as shown by exercise stress 99 Tc m -MIBI gated SPECT MPI, is a significant predictor of angiographic disease with very high specificity and positive predictive values. Exercise reversible RWMA can rise the assessment value of angiographic severity in MPI

  16. Follow-up of a case of subacute thyroiditis with uncommon thyroid {sup 99m}Tc uptake

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Zhe; Li, Chengjiang, E-mail: 10518093zz@163.com [Medical College of Zhejiang University, Hangzhou (China). Hospital of Medical College. Department of Endocrinology and Metabolism

    2013-07-01

    Thyroidal 99mTc uptake in the acute thyrotoxic phase of subacute thyroiditis (SAT) is always inhibited. However, a patient with SAT had signs in the right-side thyroid gland with transient thyrotoxicosis and slightly high 99mTc uptake levels in the right lobe, low 99mTc uptake in the left lobe, and normal overall uptake. Histological examination showed cellular destruction and granulomatous inflammatory changes in the right lobe, with marked interstitial fibrosis in the left lobe. The patient was thyrotrophin-receptor antibody (TRAb) positive. After a short course of prednisolone, SAT-like symptoms and signs improved. TRAb-positivity resolved spontaneously after 22 months, and TSH levels were slightly low for 22 months. Levels then kept normal in the following four years. In conclusion, high 99mTc uptake by the right lobe was due to the combined effects of TRAb and left thyroid gland fibrosis. (author)

  17. Pharmacological study of 99mTc-CO-MIBI, a new mycoardial perfusion imaging agent comparison to 99mTc-MIBI

    International Nuclear Information System (INIS)

    Zhao Jiandong; Wang Jincheng; Mi Hongzhi

    2004-01-01

    For many years, 99m Tc-MIBI has been widely used for the diagnosis of ischemic heart disease. Although it has been regarded as a successful myocardial imaging agent, it has a notable defect of high liver radioactivities due to high uptake and slowly excrete. Recently, researchers had developed a new intermediate [ 99m Tc(CO) 3 (OH 2 ) 3 ] + , considering 99m Tc-MIBI excellent biodistribution, they synthesized a new class of compound- 99m Tc-CO-MIBI with [ 99m Tc(CO) 3 ] + core and ligand MIBI. Previous studies have preliminary demonstrated the following favorable properties: rapid blood-pool clearance, high myocardial extraction and rapid clearance kinetics from liver that indicated 99m Tc-CO-MIBI a promising new myocardial perfusion imaging agent. Furthermore, researchers separated the compound by changing liquid pH value and prepared single alkaline component 99m Tc-CO-MIBI. The pharmacological experiments in rat have provided better results on its biodistribution in vivo and much faster clearance kinetics from liver compared to 99mTc-MIBI. To evaluate the potential application of 99m Tc-CO-MIBI, further investigations are necessary to determine the evidence for enhanced ability in clinical decision making as a novel new myocardial perfusion imaging agent. Objective: Here, perform pharmacological experiment of 99m Tc-CO-MIBI, a new technetium-99m-labeled myocardial imaging agent compared to 99m Tc-MIBI in canines. To identify whether it is feasible in clinical application as a novel myocardial imaging agent, or not. Results: Accordingly, prepared the single alkaline component of 99m Tc-CO-MIBI. The complex was stable up to at least 7 hours after synthesized in vitro at either room temperature or 37 degree C water bath. Labeling yield and radiochemical purity (RCP) of the complex were evaluated by TLC and HPLC, the labeling percent was 93%-97% and the RCP was over 90%. Then administer 555MBq to every dog each times. A total of 5 dogs were involved. The data of

  18. Detection of myocardial ischemia of hypertrophic cardiomyopathy with gated 99Tcm-MIBI myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Jia Peng; Guo Wanhua; Du Minghua; Gao Ling

    2010-01-01

    Objective: To evaluate the value of gated 99 Tc m -methoxyisobutylisonitrile (MIBI) myocardial perfusion imaging in detection of myocardial ischemia in hypertrophic cardiomyopathy. Methods: Sixty-nine patients with clinically proven hypertrophic cardiomyopathy were divided into 2 groups using coronary angiogram as 'gold standard': positive group (n=19, narrowing ≥ 50%) and negative group (n=50, narrowing 99 Tc m -MIBI myocardial perfusion imaging was performed and positive in all 69 patients (41 males, 28 females, aged 35-75 years). Comparative analysis between the two groups was carried out using t-test. Results: In the positive group, reversible and irreversible perfusion defects were detected in 9 and 10 patients, respectively. Left ventricular ejection fraction (LVEF) increased to (69.1 ± 2.8)% in 8 patients and decreased to (42.8 ± 2.1)% in 11 patients. In the negative group, reversible and irreversible perfusion defects were found in 37 and 13 patients, respectively. LVEF increased to (70.8 ± 4.0)% in 38 patients and decreased to (48.9 ± 2.7)% in 12 patients. The values of ischemic area, severity and extent of perfusion defect, and LVEF were significantly different between the two groups (t=9.28, 16.51, 2.65; P 99 Tc m -MIBI myocardial perfusion imaging is valuable in assessing patients with hypertrophic cardiomyopathy. Detection for the presence or absence of coexisting coronary artery disease and myocardial ischemia has an important prognostic indication and management indication for these patients. (authors)

  19. Tc-99m-MIBI Uptake in Active Pulmonary Tuberculosis: A Case Report

    International Nuclear Information System (INIS)

    Lee, Chang Ho; Park, Chan Hee; Hwang, Hee Sung; Bae, Moon Sun

    1996-01-01

    Technetium-99m MIBI was developed as a myocardiac perfusion imagine agent and has been used effectively in the detection and post-therapeutic evaluation of various neoplasm such as thyroid, lung, bone and breast tumors. As an infrequent findings, Tc-99m MIBI agent has shown in non-neoplastic pulmonary conditions including fibroding alveolitis, pulmonary actinomycosis, active pulmonary sarcoidosis, pulmonary interstitial fibrosis in progressive systemic sclerosis and active osteomyelitis. In a recent report conducted by Cetin Oncel, Tc-99m MIBI imaging is an effective method in the detection and follow-up of pulmonary tuberculosis. We have also experienced Tc-99m-MIBI uptake in active pulmonary tuberculosis incidentally found in a patient with suspected proliferative villonodular synovitis of the left ankle.

  20. Absorbed radiation to the nuclear medicine nurses from patients administered 201Tl and 99mTc- MIBI

    International Nuclear Information System (INIS)

    Sattari, Ali; Dadashzadeh, Simin; Nasiroghli, G.; Firoozabadi, Hasan

    2008-01-01

    People who have administrated radiopharmaceuticals could be a source of radiation to their relatives, medical nurses, and people who have contact them. In this study, the dose rates at various distances of 5, 10,50 and 100 cm from 70 patients, who were administered diagnostic amounts of 201 Tl -Chloride and 99m Tc -MIBI, was measured using an ionization chamber. For determination of external radiation dose to the nurses the radiations in three deferent interval times have measured. The maximum values of external dose rates of 201 Tl and 99m Tc-MIBI were 11.2μSv/h ±2.3 and 43.1μSv/h ±11.9 respectively at 5 cm from the patients. Significant exposure from patients after injection of 99m Tc -MIBI was limited on the day of administration. Departure doses rate of 201 Tl fell gradually so by 3 days after administration was significant. Maximum and average absorbed dose of nuclear medicine staff for one 201 Tl scan was 4.6 and 2.7μSv/h, and for 99m Tc-MIBI was 18.1 and 9.8μSv/h in a working day. (author)

  1. Measurement of left ventricular ejection fraction from gated technetium-99m sestamibi myocardial images

    International Nuclear Information System (INIS)

    Boonyaprapa, S.; Ekmahachai, M.; Thanachaikun, N.; Jaiprasert, W.; Sukthomya, V.; Poramatikul, N.

    1995-01-01

    Sixty patients underwent SPET imaging with MIBI. Immediately after SPET acquisition ECG-gated 99m Tc-MIBI perfusion images were acquired using 24 planar images per R-R interval. A new method for measurement of LVEF from the ECG-gated 99m Tc-MIBI perfusion images was developed. To validate the method, LVEF derived from MIBI perfusion images was compared with that from conventional radionuclide ventriculography in all 60 patients. Forty patients had evidence of myocardial infarction and 20 had normal perfusion on MIBI imaging. There was no statistically significant difference between LVEF computed from 99m Tc-MIBI perfusion images and that from radionuclide ventriculography (r=0.7062, P 99m Tc-MIBI perfusion images can be obtained at the same time as assessment of myocardial perfusion and in the same orientation and metabolism of the myocardium, thereby permitting more accurate and realistic prognosis and diagnosis in patients with coronary artery disease. (orig.)

  2. Double-phase parathyroid 99Tcm-MIBI scintigraphy in secondary hyperparathyroidism

    International Nuclear Information System (INIS)

    Liu Wei; Xu Zhaoqiang; Hu Jianmin; Chang Guojun; Yao Weixuan; Li Yongjun; Chen Jianwei

    1999-01-01

    Objective: To evaluate the diagnostic value of double-phase parathyroid 99 Tc m -MIBI scintigraphy in secondary hyperparathyroidism (SHP) following chronic renal failure. Methods: 99 Tc m -MIBI parathyroid scintigraphy was performed on 20 SHP patients. All images were analyzed with parathyroid/thyroid ratio (PT/T) and parathyroid index (PTI). 3 patients underwent parathyroidectomy and ectopic autografting. Results: 8 patients were 99 Tc m -MIBI-positive. 9 parathyroid glands removed from 3 patients were histopathologically diagnosed as parathyroid hyperplasia. 8 of the 9 were scintigraphy positive with the sensitivity of 88.9%, the localization of the parathyroids with scanning before operation was accurate. It was found that there were 3 types of MIBI washout in hyperplastic parathyroids. Conclusions: 99 Tc m -MIBI scintigraphy is valuable in localization of parathyroids in SHP, especially of hyperfunctioning glands. Special attention should be paid to the fact that there are different types of MIBI washout in hyperplastic glands, otherwise some abnormal glands might be missed

  3. Technetium-99m Sestamibi in Multiple Myeloma

    International Nuclear Information System (INIS)

    Saber, R.A.

    2002-01-01

    Technetium-99m 2-methoxy - isobutyl - isonitrile (99mTc-MIBI) has been reported to be useful in evaluating patients with multiple myeloma. The aim of this study is to evaluate the role of technetium-99m sestamibi (99mTc-MIBI) scintigraphy in the diagnosis. staging and follow-up of patients with multiple myeloma. Methods and Materials: twenty-five consecutive patients with multiple myeloma were studied using 99mTc- MIBI. Of the 25 patients included in this study, 6 were in stage I, II in stage II and 8 in stage III. Anterior and posterior whole-body imaging were obtained 20 min after I.V. injection of 740 MBq of 99mTc-MIBI. Four different MIBI patterns could be described in our patients: physiological (P), diffuse (D), focal (F) and combined diffuse and focal (D+F). All patients in stages II and III as well as 3 patients in stage I were treated with chemotherapy (cyclophosphamide and prednisone) then 99mTc-MlBI scans were repeated after 6 courses. Results: in comparison to conventional X-ray skeletal survey, 99mTc-MIBI scans showed a higher number of myeloma bone disease at diagnosis. All patients with stage II and III multiple myeloma were positive with 99mTc-MlBl scans at diagnosis. The pattern of positive MIBI accumulation was diffuse in 13 (52%) patients, focal in 4 (16%) and combined focal and diffuse in 6 (24%) patients. The intensity of 99mTc-MIBI correlated with disease activity as determined by lactate dehydrogenase (LDH), number of plasma cells in bone marrow and serum electrophoresis. There was a direct correlation between 99mTc-MIBI scan result and clinical outcome of patients following 6 courses of chemotherapy. Sensitivity and specificity of 99mTc-MIBI scintigraphy in detecting myeloma bone lesions were 92% and 90% respectively. Conclusion: 99mTc-MIBI scintigraphy is a reliable method to evaluate bone marrow activity in patients with multiple myeloma and follow-up of myeloma bone lesions

  4. Development of 99Mo/99mTc Generator System for Production of Medical Radionuclide 99mTc using a Neutron-activated 99Mo and Zirconium Based Material (ZBM as its Adsorbent

    Directory of Open Access Journals (Sweden)

    I. Saptiama

    2016-12-01

    Full Text Available Molybdenum produced from fission of U-235 is the most desirable precursor for 99Mo/99mTc generator system as it is non-carrier added and has high specific activity. However, in the last decade there has been short supply of 99Mo due to several constrains. Therefore, there have been many works performed for development of 99Mo/99mTc generator system using 99Mo which is not produced from either LEU or HEU. This report deals with development of 99Mo/99mTc generator system where zirconium-based material (ZBM is used as adsorbent of neutron-activated 99Mo. The system was prepared by firstly irradiating natural Mo in the G. A. Siwabessy reactor to produce neutron-activated 99Mo. The target was dissolved in NaOH 4N and then neutralized with 12 M HCl. The 99Mo solution was then mixed with a certain amount of ZBM followed by heating at 90°C for three hours to allow the 99Mo adsorbed on ZBM. The 99Mo-ZBM (9.36 GBq of 99Mo was Mo/ 4.2 g ZBM was packed on a fritz-glass column. This column was then fitted serially with an alumina column for trapping 99Mo breakthrough. The columns were then eluted daily with saline solution for up to one week. The yield of 99mTc was found to be between 53.7 – 74% (n= 5. All 99mTc eluates were clear solutions with pH of 5. Breakthrough of 99Mo in 99mTc eluates was found to be 0.031 ± 0.019 μCi 99Mo/ mCi 99mTc (n= 5 which was less than the maximum activity of 99Mo allowed in 99mTc solution ( 99%. Radiolabeling of this 99mTc towards methylene diphosphonate (MDP kit gave a radiolabelling efficiency of 99%. In summary, a new 99Mo/99mTc generator system that used neutron-activated 99Mo and ZBM as its adsorbent has been successfully prepared. The 99mTc produced from this new 99Mo/99mTc generator system attained the quality of 99mTc required for medical purposes.

  5. Comparison between radioisotopic ventriculography in balance with Tc99-albumine-DTPA and quantitative gated SPECT with Tc-99m-MIBI for determining the eject fraction of left ventricle

    International Nuclear Information System (INIS)

    Noguera, E. C; Jaime, Adelina; Pamellin, Miriam; Veliz, J

    2002-01-01

    Radionuclide ventriculography (RNV) and electrocardiography gated myocardial perfusion single photon emission computed tomography (GSPECT), can be used to assess the ventricular function.The purpose of this study was:1) to compare left ventricular ejection fraction (LVEF(%) using post-stress or rest gated GSPECT with LVEF by resting RNV and 2) to evaluate the 99m-Tc99m human serum albumin (HAS) with diethylenetriaminepenta-acetic acid (DTPA) (99m-TcHSA-DTPA) as a potential use a as blood pool imaging agent (Au)

  6. Use of {sup 99m}Tc 2-methoxyisobutyl isonitrile in minimally invasive radioguided surgery in patients with primary hyperparathyroidism: A narrative review of the current literature

    Energy Technology Data Exchange (ETDEWEB)

    Denmeade, Kristie A [Nuclear Medicine and Ultrasound Department, Bankstown-Lidcombe Hospital, Bankstown, New South Wales (Australia); Constable, Chris [Brain and Mind Research Institute, University of Sydney, New South Wales (Australia); Reed, Warren M [Discipline of Medical Radiation Sciences, Faculty of Health Sciences, The University of Sydney, New South Wales (Australia); Nuclear Medicine and Ultrasound Department, Bankstown-Lidcombe Hospital, Bankstown, New South Wales (Australia)

    2013-06-15

    The use of technetium-99m 2-methoxyisobutyl isonitrile ({sup 99m}Tc MIBI) for assistance in minimally invasive radioguided surgery (MIRS) is growing in popularity as a safe, effective, and proficient technique used for parathyroidectomy in primary hyperparathyroidism (PHPT) treatment. Previously, the preferred treatment for PHPT was bilateral neck exploration (BNE), a very invasive, costly, and lengthy procedure. However, as a large majority (80–85% of cases of PHPT) are attributed to a single parathyroid adenoma (PA), a simpler more direct technique such as MIRS is a far better option. The following article is an exploration of the current literature concerning varied protocols utilizing {sup 99m}Tc MIBI for assistance in MIRS for patients undergoing treatment of PHPT. This technique boasts many advantageous outcomes for patients suffering from PHPT. These include a reduction in cost, operating time, and patient recovery; less evidence of post-surgical hypocalcaemia, less pain, and complications; superior cosmetic results; same-day discharge; and the possibility of local anaesthesia which is particularly beneficial in elderly patients. Better outcomes for patients with deep or ectopic PAs, reduced intra-operative complications, and improved cosmetic outcomes for patients who have previously undergone thyroid and/or parathyroid surgery are also advantageous. Of the literature reviewed it was also found that no patients suffered any major surgical complications such as laryngeal nerve palsy or permanent hypoparathyroidism using {sup 99m}Tc MIBI for assistance in MIRS.

  7. Dual-Phase 99MTc-MIBI Parathyroid Imaging Reveals Synchronous Parathyroid Adenoma and Papillary Thyroid Carcinoma: A Case Report

    Directory of Open Access Journals (Sweden)

    Ming-Che Chang

    2008-10-01

    Full Text Available The possibility of a coincidental appearance of hyperparathyroidism and thyroid cancer is not often considered because of its low incidence. Here, we present a case of a 49-year-old woman with a parathyroid adenoma coexisting with two sites of papillary thyroid carcinoma. Dual-phase 99mTc-methoxyisobutylisonitrile (MIBI parathyroid imaging before the operation correctly visualized the site of the parathyroid adenoma. In addition, two papillary thyroid carcinomas showed faint uptake of 99mTc-MIBI on delayed image. Total thyroidectomy and parathyroidectomy of a solitary parathyroid adenoma were performed. The patient subsequently underwent radioiodine-131 ablation and was treated with T4 suppression. This case illustrates the need for clinical awareness of concomitant hyperparathyroidism and thyroid cancer. Dual-phase 99mTc-MIBI parathyroid imaging may be useful for detecting indolent thyroid cancer before it becomes a distinct disease.

  8. The preparation and biodistribution of a new 99Tcm-nitrito complex 99TcmN-MIBI

    International Nuclear Information System (INIS)

    Zhang Xianzhong; Wang Xuebin; Zhang Junbo

    1997-01-01

    The technetium-99m nitrito intermediate is synthesized by using SnCl 2 ·2H 2 O as reductant, and the complex 99 Tc m N-MIBI is obtained through ligand exchange reaction. The labelling yield of 99 Tc m N-MIBI is over 95% by TLC. The conditions of preparing 99 Tc m N-MIBI are optimized. Results of stability and partition coefficient of 99 Tc m N-MIBI indicate that the complex is lipophilic and stable over 10 h at room temperature. The biodistribution of 99 Tc m N-MIBI in mice shows high myocardium uptake, and rather rapid clearance. For 5-min post-injection the heart-to-blood, heart-to-lung and heart-to-liver ratios are 3.18, 1.72 and 1.42, respectively. The new complex may be suitable for instant myocardial imaging. 99 Tc m N-MIBI has significant different biodistribution characteristics from 99 Tc m -MIBI. Based on these promising properties, 99 Tc m N-MIBI should be a new potential myocardial perfusion imaging agent

  9. Bone scintigraphy with 99m Tc MIBI. Its importance for the detection of malignant bone tumors

    International Nuclear Information System (INIS)

    Marrero, Luis O.; Tamayo, Alicia; Rodriguez, Oscar; Solano, Maria E.; Perera, Alejandro; Perez, Marylin

    1997-01-01

    99mT c-MIBI is a radiopharmaceutical widely employed for the detection and follow-up of different oncological diseases. The aim of the present work was to determine the value of the scintigraphy with 99mT c-MIBI for the diagnosis of malignant bone tumors, its metastases and recurrences. Twenty patients aged 24+- years old, suspected of having bone neoplasms, were studied. I

  10. Single isotope dual-phase scintigraphy with 99mTc-MIBI and 99mTc-tetrofosmin combined with SPECT technique in patients with secondary hyperparathyroidism

    International Nuclear Information System (INIS)

    Botushanova, A.; Yaneva, M.; Botushanov, N.

    2015-01-01

    Full text: Preoperative parathyroid scintigraphy is highly beneficial when used for minimally invasive parathyroidectomy. The aim is to examine the diagnostic value of single isotope dual-phase scintigraphy with 99mTc-MIBI and 99mTc-etrofosmin combined with SPECT technique in preoperative localization of hyperplastic parathyroid glands in patients with secondary hyperparathyroidism. The study included 15 patients aged 37 to 73 years (8 women and 7 men) with proven secondary hyperparathyroidism with increased serum calcium and parathyroid hormone. All patients were on chroniodialysis and treatment with Calcitriol. The examination was done with two-headed SPECT gamma camera SIMBIA by protocol for single isotope dual-phase scintigraphy and SPECT technique. 740 MBq 99mTc-MIBI were applied intravenously in 6 of the patients, and in 9 patients were administered 740 MBq 99mTc-tetrofosmin. The scintigraphy with 99mTc-MIBI visualized a focus of residual activity in 4 patients, and in 2 we received negative scintigraphy. The scintigraphy with 99mTc-tetrofosmin combined with SPECT showed an area of hyperfixation in both phases on SPECT images in 1 patient. In 2 patients hyperfixating areas suspicious for abnormal parathyroid glands were registered only in the early SPECT images. In 6 patients the scintigraphic results were negative. Negative scintigraphic results can be explained with the ability to suppress the uptake of 99mTc-MIBI and 99mTc - tetrofosmin by the parathyroid cells as a result of taking Calcitriol. Scintigraphy with 99mTc-MIBI and 99mTc-tetrofosmin did not show high sensitivity in identifying the hyperplastic parathyroid glands, although it was capable to distinguish patients with nodular hyperplasia of those with diffuse hyperplasia

  11. Localization diagnosis of hyperfunctional parathyroid gland using 99Tcm-MIBI and 99TcmO4- imaging

    International Nuclear Information System (INIS)

    Zhang Fenru; Deng Huixing; Duan Xiaoyi; Xue Jianjun; Gao Rui

    2010-01-01

    Objective: To study the localization diagnosis value of nuclide imaging by 99 Tc m -MIBI double phase parathyroid combined with 99 Tc m O 4 - thyroid imaging in patients with hyperparathyroidism (HPT). Methods: Patients with primary HPT were 36 cases. Control groups were 10 cases with thyroid disease. Early phase imaging was performed in 15 minute after injecting imaging agent 99 Tc m -MIBI. Delay phase imaging was performed in 2 hours. 36 HPT patients and 10 cases control groups were also performed 99 Tc m O 4 - thyroid imaging 24 hours later. The two kinds of imaging were compared with each other, were analyzed, and were underwent imaging subtracted by eyes and imaging results judgment. Results: In 36 cases of HPT patients, 34 cases showed positive result imaging with 99 Tc m -MIBI/ 99 Tc m O 4 - imaging. 2 cases showed false negative result. Positive rate was 94.44 % with 99 Tc m -MIBI/ 99 Tc m O 4 - imaging. The positive result imaging showed abnormal increased uptake of 99 Tc m -MIBI. In 36 cases of HPT patients, 12 cases showed positive result with single 99 Tc m -MIBI imaging. 4 cases showed false negative imaging. 20 cases showed ambiguous positive results. Positive rate was 88.89% (55.56% was ambiguous positive results) with single 99 Tc m -MIBI imaging. In 10 cases control groups, 3 cases showed false positive results with single 99 Tc m -MIBI imaging. 1 case showed ambiguous false positive results. No case showed false positive result with 99 Tc m -MIBI/ 99 Tc m O 4 - imaging. Conclusion: 99 Tc m -MIBI parathyroid double phase imaging combined with 99 Tc m O 4 - thyroid imaging have important value for diagnoses and localization of hyperparathyroidism. 99 Tc m -MIBI/ 99 Tc m O 4 - imaging have higher positive rate and higher specificity than single 99 Tc m -MIBI imaging for diagnoses and localization of hyperfunction parathyroid gland. (authors)

  12. The prognostic value of 99MTc-MIBI stress-rest myocardial perfusion imaging in patients suspected with coronary artery disease

    International Nuclear Information System (INIS)

    Wu Zhifang; Li Sijin; Liu Jianzhong; Zhang Wanchun

    2004-01-01

    Objective: To evaluate the prognostic value of 99mTc-MIBI stress-rest myocardial perfusion imaging (MPI) for patients suspected with coronary artery disease (CAD). Methods: 206 consecutive patients suspected with CAD (165 males, 41 females; age range 16-90 years, mean age 55.94±12.46 years) underwent 99mTc-MIBI stress-rest myocardial perfusion imaging (two days protocol), 57 pts with hypertension, 68 pts with hyperlipemia, 39 pts with diabetes and 62 pts with the family history of CAD. According to the imaging results, the 206 patients were divided into 3 groups. G1, normal, 135 pts; G2, reversible defects, 20 pts; G3, fixed defects, 51 pts. The mean time of follow-up was 33.25±14.95 (1-56) months. Results: The rate of cardiac events (CE) occurrence of the three groups was 1.5% (2/135), 65% ( 13/20) and 7.8% (4/51) respectively and there was significant difference between them. Kaplan-Meier survival curves analyzing the no-CE rates in the three groups, ischemic patients demonstrated a more significantly lower than normal and infarction ones in the no-CE rates(Log-rank statistic, chi-square 124.89, P <0.0001). The better predictor of future cardiac events is the reversible defect. Over all, 23.9% of the patients with abnormal stress MPI occurred cardiac events, but only 7.5% of the patients with abnormal rest ones did(chi-square 5.80, P =0.016). The prognoses of patients with normal stress MPI result were better than those with normal rest ones (1.5% versus 9.7%, chi-square 8.94, P =0.0028). Compared with rest MPI, the stress one is a better predictable method to analyze the patient' s condition and evaluate the prognosis. Conclusions: 99mTc-MIBI stress-rest myocardial perfusion imaging is a better Methods to evaluate the prognosis of patients suspected with CAD, and the rate of CE occurrence was 65% in reversible defects patients in this study. (authors)

  13. Prediction of improvement of myocardial wall motion after coronary artery bypass surgery using rest Tl-201/dipyridamole stress gated Tc-99m-MIBI/24 hour delay Tl-201 SPECT

    International Nuclear Information System (INIS)

    Lee, Dong Soo; Lee, Won Woo; Yeo, Jeong Yeo; Kim, Seok Ki; Kim, Ki Bong; Chung, June Key; Lee, Myung Chul

    1998-01-01

    Using rest Tl-201/ dipyridamole stress gated Tc-99m-MIBI/24 hour delay Tl-201 SPECT, we investigated the predictive values of the markers of the stress-rest reversibility (Rev), Tl-201 rest perfusion (Rest), Tl-201 24 hour redistribution (Del) and Tc-99m-MIBI gated systolic thickening (Thk) for wall motion improvement after coronary artery bypass surgery. In 39 patients (M:F=34:5, age 58±8), preoperative and postoperative (3 months) SPECT were compared. 24 hour delayed SPECT was done in 16 patients having perfusion defects at rest. Perfusion or wall motion was scored from 0 to 3 (0: normal to 3: defect or dyskinesia). Wall motion was abnormal in 142 segments among 585 segments of 99 artery territories which were surgically revascularized. After bypass surgery, ejection fraction increased from 37.8±9.0% to 45.5±12.3% in 22 patients who had decreased ejectin fraction preoperatively. Wall motion improved in 103 (72.5%) segments among 142 dysfunctional segments. Positive predictive values (PPV) of Rev, Rest, Del, and Thk were 83%, 76%, 43%, and 69% respectively. Negative predictive values (NPV) of Rev, Rest, Del, and Thk were 48%, 44%, 58%, and 21%, respectively. Rest/gated stress/delay SPECT had PPV of 74% and NPV of 46%. Through univariate logistic regression analysis revealed Rev( p=0.0008) and Rest (p=0.024) as significant predictors, stepwise multivariate test found Rev as the only good predictor (p=0.0008). Among independent predictors obtained by rest Tl-201/stress gated Tc-99m-MIBI/delayed Tl-201 myocardial SPECT for wall motion improvement after bypass surgery, stress-rest reversibility was the single most useful predictor

  14. Scintigraphy with 99MTC-MIBI in the assessment and the prediction of multidrug resistance in patients with lymphoma

    International Nuclear Information System (INIS)

    Peña Quian, Yamilé; Perera Pintado, Alejandro; Batista Cuellar, Juan F.; Prats Capote, Anaís; Coca Pérez, Marco A.; Sánchez González, Yolaine; Quesada Pozo, Rodobaldo; Hernández Ramírez, Porfirio; Silva Marín, Caridad; Morales Pérez, Ernesto; Peña Coego, Andria; Toirac Garcías, Noresma

    2007-01-01

    To determine the utility of scintigraphy with 99m Tc-MIBI for non-invasively assessment and prediction of multidrug resistance in patients with lymphoma. 152 patients were evaluated (120 with lymphoma and 32 with benign diseases of the lymph nodes). The biopsy of lymph nodes constituted the gold standard. Static images of thorax, abdomen and pelvis were acquired at 20 min, 2h, 3h and 4h after the intravenous administration of 925-1110 MBq (20-30 mCi) of 99m Tc-MIBI. The uptake indexes were determined for each time and the index of maximum uptake (ICmax) of the radiopharmaceutical for all patients was also calculated. The index of maximum uptake was compared with the clinical and hematological response to chemotherapy. The studies with 99m Tc-MIBI showed values of sensibility, specificity and diagnostic accuracy of 96%, 75% and 92%, respectively. Once chemotherapeutic treatment was concluded, 48 of the 120 studied patients with lymphoma showed complete remission of the disease, meanwhile 32 of them showed partial remission and non response to chemotherapy was observed in 40 cases. The outcomes of the present work revealed that a high index of maximum uptake (ICmax ≥6) could be an indicator of good response to chemotherapy, values of ICmax in a range from 3 to 6 were associated to either complete or partial remission and a ICmax ≤3 could be an indicator of poor response to chemotherapy. The scintigraphy with 99m Tc-MIBI was a useful tool for the study of patients with lymphoma and the assessment of their response to chemotherapy. (author)

  15. Usefulness of Technetium 99 m- Sestamibi (MIBI) scintigraphy in the detection of parathyroid adenoma and hyperplasia

    International Nuclear Information System (INIS)

    Markarian, Maria F.; Yelin, Enrique G.; Aparicio, Rocio; Marino, Juan M.

    2005-01-01

    Purpose: To evaluate parathyroid substration scintigraphy with Tc99m-pertechnetate-Tc99m-MIBI, for detection of parathyroid adenomas or hyperplasia in patients with hyperparathyroidism. Materials and methods: Thirty patients were studied by Tc99m-pertechnetate-Tc99m-MIBI scintigraphy, 24 with primary hyperparathyroidism, 2 with hypo echogenic nodular image behind the thyroid gland, 1 with bone fracture history, 1 with hypophosphataemia and 2 with secondary hyperparathyroidism. The initial image was made with pertechnetate, the next one and the late (2-3 hs) with Tc99m-MIBI, making digital substration with the first image. Six patients were excluded (difficult follow-up n=5, death n=1). Results: The final 24 patients series showed: 10 positive and 12 negative for adenomas; 1 positive and 1 negative for hyperplasia. The correlation between the scintigraphic study and the clinical, biochemical and anatomicopathological data, showed a high sensitivity (90%), and specificity (92%), for parathyroid adenomas and/or hyperplasia. Conclusions: The Tc99m-pertechnetate-Tc99m-MIBI shows high sensitivity and high specificity for the detection of adenomas and hyperplasia in patient with hyperparathyroidism. (author)

  16. Monitoring of response to the treatment with ganglionic gamma radiography with 99Tc-MIBI in lymphomas

    International Nuclear Information System (INIS)

    Solano, Maria E.; Gomez, Jose Ramon.

    1997-01-01

    Recently the use of 99m Tc-MIBI for the diagnosis and follow-up of lymphomas have been reported. The aim of the present work was to assess the utility of this radiopharmaceuticals for the post treatment follow-up of patients lymphomas

  17. Tc-99m MIBI SPECT in prediction of prognosis in patients with small cell lung cancer

    International Nuclear Information System (INIS)

    Akgun, A.; Cok, G.; Karapolat, I.; Goksel, T.; Burak, Z.

    2006-01-01

    The purpose of this study was to evaluate whether the degree of technetium-99m methoxyisobutylisonitrile (MIBI) uptake and its retention in delayed imaging in small cell lung cancer (SCLC) was correlated with the response to multiagent chemotherapy and to investigate if there was a relationship between the survival time of patients with SCLC and Tc-99m MIBI SPECT tumor uptake parameters at the time of diagnosis. Between 1998 and by December 2004, 40 patients with SCLC were studied with Tc-99m MIBI SPECT at the time of diagnosis. The patients were classified by a follow-up CT as good responders (complete or partial remission) and poor responders (stable disease or progressive disease). Following i.v. administration of 740 MBq Tc-99m MIBI, SPECT imaging at 30 minutes (early) and 2 hours (delayed) was performed. Regions of interests were placed over the tumors and contralateral normal lung tissue on one transverse section. The uptake ratio of the lesion to that in the contralateral normal lung was obtained from early images (early ratio; ER) as well as delayed images (delayed ratio; DR). The retention index (RI%) was measured as: RI%=[(DR-ER)/ER] x 100. Tc-99m MIBI tumor uptake parameters were compared with chemotherapeutic response and survival time. Of 40 patients, 29 patients were good responders (72.5%) and 11 patients were poor responders (27.5%). RI% of Tc-99m MIBI SPECT in the group of good response was significantly higher than in that with poor response (p<0.05). On the other hand, there was no significant difference between the two groups with respect to ER or DR values. Four of 40 patients were still alive with disease (10%). The patient survival time varied from 1 to 70 months (mean survival time=12.9±13.4 months). There was no significant difference between the survival time of patients with respect to ER or DR of Tc-99m MIBI SPECT imaging. When median RI% was accepted as a cut-off value (-3.85%), patients with higher RI% values had a longer survival

  18. Property of electrocardiogram gated single photon emission tomography by 99mTc-methoxy isobutyl isonitrile

    International Nuclear Information System (INIS)

    Imai, Kamon; Nishio, Yukari; Araki, Yasushi; Saito, Satoshi; Ozawa, Yukio; Yasugi, Tadao; Hagiwara, Kazuo; Kamata, Rikisaburo

    1992-01-01

    99m Tc-methoxy isobutyl isonitrile (MIBI) is a new developed myocardial perfusion imaging agent. Because this compound has higher photon energy than thallium (Tl), electrocardiogram gated single photon emission tomography (SPECT): end-diastolic (ED) and end-systolic (ES) short axis (SA) images could be taken. To investigate property of gated MIBI SPECT, MIBI myocardial scintigraphy, Tl scintigraphy (TMS) and analysis of left ventricular wall motion were performed in 6 patients with myocardial infarction. Left ventricule was divided into 8 segments. Perfusion defect (PD) was scored: '0' (normal), '1' (hypo-perfusion), '2' (defect). Wall motion abnormality (WMA) was also scored: '0' (normo-kinesis), '1' (hypo-kinesis), '2' (a-, dys-kinesis). Severity and extent of PD and WMA were calculated. Severity of WMA was 3.0±2.0 (M±SD), severity of PD was 3.3±1.7 in TMS, 3.7±1.3 in no-gated MIBI, 5.0±0.6 in ES-MIBI, 7.3±2.0 in ED-MIBI. Extent of WMA was 2.3±1.0. Extent of PD was 2.5±1.3 in TMS, 3.0±1.6 in no-gated MIBI, 3.5±0.8 in ES-MIBI, 4.8±1.0 in ED-MIBI. Compared with wall motion abnormality, severity and extent of PD in ED-MIBI was larger. From our data, it is concluded that perfusion defect in ED-MIBI was overestimated significantly. When we evaluate gated MIBI image, we must consider this property. (author)

  19. The efficacy of low and high dose (99m)Tc-MIBI protocols for intraoperative identification of hyperplastic parathyroid glands in secondary hyperparathyroidism.

    Science.gov (United States)

    Gencoglu, Esra Arzu; Aktas, Ayse

    2014-01-01

    The aim of this study was to compare the efficacy of low- and high-dose (99m)Tc-MIBI protocols for intraoperative identification of hyperplastic parathyroid glands via gamma probe in secondary hyperparathyroidism. This retrospective study was conducted using a prospective database of 59 patients who had undergone radioguided subtotal parathyroidectomy between 2004-2012. The patients were studied in 2 groups. Group 1 (n=31) received 37 MBq (99m)Tc-MIBI intravenously in the surgical room approximately 10 min before the beginning of the intervention and surgery was performed under gamma probe guidance. Group 2 (n=28) received 555 MBq (99m)Tc- MIBI intravenously 2h before surgery, which was also performed under gamma probe guidance. Intraoperative gamma probe findings, laboratory findings, and histopathological findings were evaluated together. Using acceptance of the histopathological findings as gold standard, sensitivity and specificity of intraoperative gamma probe for identifying hyperplastic parathyroid glands was 98% and 100%, respectively, in both groups. In the light of these findings, it is concluded that the low-dose (99m)Tc-MIBI protocol might be preferable for intraoperative identification of hyperplastic parathyroid glands in secondary hyperparathyroidism patients because it was observed to be as effective as the high-dose (99m)Tc-MIBI protocol. Furthermore, the low-dose protocol does not have the disadvantages that are associated with the high-dose protocol. Copyright © 2014 Elsevier España, S.L. and SEMNIM. All rights reserved.

  20. Concentration of sup(99m)Tc from the eluate of 99Mo-sup(99m)Tc generators

    International Nuclear Information System (INIS)

    Saucedo, T.; Mora, M.; Fraga de Suarez, A.H.; Mitta, A.E.A.

    1976-04-01

    A method is described to concentrate sup(99m)Tc solutions, originated in 99 Mo-sup(99m)Tc generators, independent of its age. The techniques of preparation of the different radiopharmaceuticals used in nuclear medicine are also described. (author) [es

  1. Preoperative localization of parathyroid carcinoma using Tc-99m MIBI.

    Science.gov (United States)

    Kitapçi, M T; Tastekin, G; Turgut, M; Caner, B; Kars, A; Barista, I; Bekdik, C

    1993-03-01

    A patient with parathyroid cancer is presented who underwent Tc-99m MIBI scintigraphy. The Tc-99m MIBI image demonstrated increased accumulation of activity at the lower pole of the left thyroid lobe which was later confirmed as a parathyroid cancer. Uptake by parathyroid cancer must be kept in mind as a cause of increased Tc-99m MIBI accumulation when a disease is in question in the thyroid or parathyroid gland.

  2. 99mTc-Tetrofosmin scintimammography in suspected breast cancer patients: comparison with 99mTc-MIBI

    International Nuclear Information System (INIS)

    Kim, Seong Jang; Kim, In Ju; Kim, Yong Ki; Bae, Young Tae

    2000-01-01

    The aim of this study was to investigate the diagnostic role of 99m Tc-Tetrofosmin in detection of breast cancer and compared with that of 99m Tc-MIBI. Forty-eight patients with a clinically palpable mass or abnormal mammographic or ultrasonographic findings had 99m Tc-MIBI and 99m Tc-Tetrofosmin scintimammographies after intravenous injection of 925 MBq of radiopharmaceuticals. The scintimammographs were correlated with histopathologic findings. Thirty-three patients were diagnosed with breast cancer and 15 patients with benign breast diseases. The numbers of true positive, true negative, false positive, and false negative cases of 99m Tc-MIBI scintimammography were 29, 10, 5, and 4 respectively. The sensitivity, specificity, positive predictive value, and negative predictive value of 99m Tc-MIBI scintimammographies were 87.8%, 66.7%, 85.3%, and 71.4% respectively. The numbers of true positive, true negative, false positive, and false negative cases of 99m Tc-Tetrofosmin were 31, 10, 5, and 2 respectively. The sensitivity, specificity, positive predictive value, negative predictive value of 99m Tc-Tetrofosmin were 93.9%, 66.7%, 86.1%, and 73.3% respectively. One patient was false negative in both 99m Tc-Tetrofosmin scintimammographies and its size was 0.5cm. 99m Tc-Tetrofosmin and 99m Tc-MIBI were non-invasive and useful in detection of breast cancer and 99m Tc-Tetrofosmin was comparable to the 99m Tc-MIBI in detection of primary breast cancer.=20

  3. Usefulness of 99mTc-Sestamibi whole body scan in the follow-up of differentiated thyroid cancer

    International Nuclear Information System (INIS)

    Pastore, Francisco A.; Fernandez, C.; Rios, V.; Funes Lorea, A; Volpe, B.; Lopez, S.

    2006-01-01

    Although radioiodine is and had been the more common used radioisotope in the follow-up of differentiated thyroid cancer (DTC), other radioisotopes, such as 99m Tc sestamibi (MIBI), had been incorporated as auxiliary methods. Our objective was to assess the diagnostic usefulness of MIBI in the long term follow-up of DTC. Thirty-two patients (26 (81%) female), mean age 45 ± 12.6 years, 2 with follicular carcinoma, and 30 with papillary carcinoma, were prospectively studied with MIBI. Mean time of follow-up from thyroidectomy to MIBI was 4.6 ± 4.9 years. (range, 7 months to 22 years). Sensitivity (Sens), specificity (Spec), positive predictive value (PPV), negative predictive value (NPV), and accuracy (A) was evaluated. We assessed agreement for MIBI and 131 I, by means of percent agreement and Cohen's kappa (k) statistic. The gold standard method to indicate persistent disease was serum thyroglobulin (Tg) measurement by ICMA, with cut-off level of = 2 ng/ml 'off T4', and > 0.2 ng/ml 'on T4'. In 3 patients with positive anti-Tg antibodies, 131 I scan and other auxiliary methods (Ultrasound, CT scan) were considered as gold standard. For MIBI the values of Sens, Spec, PPV, NPP, and A were 29% (26-32), 93% (89-96), 83% (74-91), 53% (51-55), and 59% (57-61), respectively. For 131 I were 31% (27-34), 100% (96-100), 100% (90-100), 56% (53-58), and 63% (61-65), respectively. The percent agreement between both radiopharmaceuticals was 76.6%, and k was 0.2 (-0.19 -0.63). Similar statistical indicators for MIBI and 131 I warrant the use of the former as alternative method. At the same time, a fair agreement between both radiopharmaceuticals demonstrates the additive information offered by MIBI in the follow-up of DTC. (author) [es

  4. Evaluation of left ventricular ejection fraction from radial long-axis tomography. A new reconstruction algorithm for ECG-gated technetium-99m Sestamibi SPECT

    International Nuclear Information System (INIS)

    Tsujimura, Eiichiro; Kusuoka, Hideo; Uehara, Toshiisa

    1997-01-01

    Radial long-axis tomography can provide views similar to contrast left ventriculography (LVG) including the basal and apical areas of the left ventricle, not possible in routine short-axis tomography. We applied this method to ECG-gated Tc-99m Sestamibi (MIBI) myocardial SPECT images to estimate the left ventricular ejection fraction (LVEF). ECG-gated Tc-99m MIBI SPECT was performed with a temporal resolution of 10 frames per R-R interval. LVEF was calculated on the basis of left ventricular volume estimates at end diastole (ED) and end systole (ES) with using an ellipsoid body model. To validate this method, LVEF's derived from ECG-gated Tc-99m MIBI SPECT were compared with those from LVG in 11 patients with coronary artery disease. There was a close linear correlation between LVEF values calculated from Tc-99m MIBI SPECT and those from LVG (r=0.89, p<0.001), although the gated SPECT underestimated LVEF compared to LVG. The technique showed excellent reproducibility (intra-observer variability, r=0.96, p<0.001; inter-observer variability, r=0.71, p<0.005). The radial long-axis tomography technique gives a good estimate of LVEF, in agreement with estimates based on LVG. ECG-gated Tc-99m MIBI SPECT can, therefore, be applicable to assess myocardial perfusion and ventricular function at the same time. (author)

  5. Evaluation of left ventricular ejection fraction from radial long-axis tomography. A new reconstruction algorithm for ECG-gated technetium-99m Sestamibi SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Tsujimura, Eiichiro; Kusuoka, Hideo; Uehara, Toshiisa [Osaka Univ. (Japan). Faculty of Medicine] [and others

    1997-08-01

    Radial long-axis tomography can provide views similar to contrast left ventriculography (LVG) including the basal and apical areas of the left ventricle, not possible in routine short-axis tomography. We applied this method to ECG-gated Tc-99m Sestamibi (MIBI) myocardial SPECT images to estimate the left ventricular ejection fraction (LVEF). ECG-gated Tc-99m MIBI SPECT was performed with a temporal resolution of 10 frames per R-R interval. LVEF was calculated on the basis of left ventricular volume estimates at end diastole (ED) and end systole (ES) with using an ellipsoid body model. To validate this method, LVEF`s derived from ECG-gated Tc-99m MIBI SPECT were compared with those from LVG in 11 patients with coronary artery disease. There was a close linear correlation between LVEF values calculated from Tc-99m MIBI SPECT and those from LVG (r=0.89, p<0.001), although the gated SPECT underestimated LVEF compared to LVG. The technique showed excellent reproducibility (intra-observer variability, r=0.96, p<0.001; inter-observer variability, r=0.71, p<0.005). The radial long-axis tomography technique gives a good estimate of LVEF, in agreement with estimates based on LVG. ECG-gated Tc-99m MIBI SPECT can, therefore, be applicable to assess myocardial perfusion and ventricular function at the same time. (author)

  6. Results of regular study on radionuclidic purity of sup(99m)Tc obtained from 99Mo-sup(99m)Tc generators

    International Nuclear Information System (INIS)

    Vlcek, J.; Rohacek, J.; Husak, V.

    1979-01-01

    A total of 39 sup(99m)Tc eluates obtained from 9 99 Mo-sup(99m)Tc generators delivered by The Radiochemical Centre Amersham during one year was studied with regard to their radionuclide purity. Using a Ge(Li) spectrometer the contaminants 60 Co, 103 Ru, 131 I, 134 Cs, 140 La and 188 Re were found in sup(99m)Tc-eluates with average levels ranging from 2.9 x 10 -3 to 2.8 x 10 -1 per cent of sup(99m)Tc activity. The additional total body absorbed dose caused by these contaminants, as calculated from their average content in sup(99m)Tc eluates, was less than 1% of the dose due to sup(99m)Tc pertechnetate. (orig.) 891 MG/orig. 892 CS [de

  7. The role of quantitative Tc-99m-MIBI gated SPECT/F-18-FDG PET imaging in the monitoring of intracoronary bone marrow cell transplantation

    International Nuclear Information System (INIS)

    Kaminek, M.; Myslivecek, M.

    2006-01-01

    A lot of unresolved questions still exist concerning the exact mechanism of the beneficial effects of bone marrow cell (BMC) transplantation for myocardial regeneration. The aim of this communication is to report the cases of patients with and without post-transplantation left ventricular function improvement. To this study we included consecutive patients with irreversible damage after a first acute ST-elevation myocardial infarction treated by coronary angioplasty with stent implantation. The irreversible damage was identified by dobutamine echocardiography and confirmed by rest gated Tc-99m-MIBI gated SPECT and in the majority of patients by F-18-FDG PET imaging as well. Using 4D-MSPECT software, we quantified MIBI/FDG uptake and gated SPECT left ventricular ejection fraction, end-diastolic/end-systolic volumes (LVEF, EDV/ESV) before BMC therapy and 3 months later. The results obtained in the initial group of patients in this study (27 patients in the BMC treated group, 16 patients in the control group) have been published previously [Eur J Nucl Med 2005; 32 (Suppl 1 ): S46]. Among the BMC group, we identified 13 responders to therapy with average LVEF improvement from 43.3%± 11% to 51.4%± 10.4% and EDV/ESV improvement from 145 ml/84 ml to 133 ml/67 ml. The remaining 14 patients were non-responders to therapy with no significant change in LVEF (39.1%±8.1% versus 39.8% ± 7.4%), the EDV/ESV increased from 166 ml/105 ml to 188 ml/116 ml. Responders to the cell therapy had prevailing MIBI uptake in the range of 31-50% of maximum in the infarction territory. On the other hand, non-responders to BMC therapy had prevailing MIBI uptake in the range of 0-30% of maximum. Two cases are presented in this report. Further studies with a larger cohort of patients would be helpful to evaluate our findings. We observed strong interindividual differences in the effectiveness of the cell therapy. Prevailing residual MIBI uptake in the range of 31-50% of maximum was in the

  8. Bone uptake of Tc-99m MIBI in patients with hyperparathyroidism

    International Nuclear Information System (INIS)

    Zhao, Yunyun; Wang, Qian

    2014-01-01

    The study aimed to investigate the incidence of bone uptake of tracer on Tc-99m MIBI imaging and explore its influencing factors and significance for diagnosis of metabolic bone disease (MBD) in patients with hyperparathyroidism (HPT). Seventy-nine consecutive patients with histopathologically confirmed HPT (63 primary and 16 secondary) who had preoperative Tc-99m MIBI imaging were retrospectively evaluated. Serum calcium (Ca), phosphorus (P), and intact parathyroid hormone (iPTH) were measured for all patients, and serum alkaline phosphatase (ALP) was measured for 62 patients. Of the 79 patients, 50 underwent bone mineral density (BMD) examination and 30 underwent bone scintigraphy. The incidence and characteristics of abnormal bone uptake of MIBI were recorded. Mann-Whitney test was performed to determine if serum iPTH, Ca, P, ALP, and BMD were different between the patients with and without MIBI bone uptake. Logistic regression analysis was used to analyze the factors that influence the bone uptake of MIBI. The concordance rate between Tc-99m MIBI imaging and bone scintigraphy in delineating MBD was calculated. Tc-99m MIBI imaging disclosed the abnormal bone uptake of tracer in 22 (27.8%) patients. Of them, 19 showed diffusely increased activity in skeleton, 2 showed focal uptake in brown tumors, and one showed both above patterns. Patients with bone uptake MIBI had higher level of serum iPTH (Z=-4.34, P < 0.001) and ALP (Z=-3.50, P < 0.001) than those without bone uptake. Logistic regression analysis also showed that bone uptake of MIBI was correlated with serum iPTH (OR=4.42, P < 0.001) and ALP (OR=3.21, P=0.002). Among the 30 patients that underwent bone scintigraphy, 76.7% patients showed signs of MBD, and the concordance rate between Tc-99m MIBI imaging and bone scintigraphy was 60% for detecting MBD. Bone uptake of MIBI in patients with HPT is commonly related to a high level of iPTH and ALP; it probably reflects an active stage of MBD, and it should be

  9. sup(99m)Tc-2-mercaptopropionylglycine

    International Nuclear Information System (INIS)

    Saji, Hideo; Odori, Teruo; Morita, Rikushi; Yokoyama, Akira; Tanaka, Hisashi.

    1979-01-01

    Labeling of 2-mercaptopropionylglycine (2-MPG) with sup(99m)Tc, was studied and its chemical characteristics were examined. Further, biliary excretion behavior of this complex was comparatively estimated in mice, rats and rabbits. sup(99m)Tc-2-MPG was rapidly excreted in large quantities into the bile in mice and rats: within 1 hr after injection, 51% of the injected dose was recovered from the bile in rats. On the other hand, the ligand exchange reaction between this complex and penicillamine indicates that a low hydrolyzed sup(99m)Tc species is coordinated with 2-MPG. These results suggest that a low hydrolyzed sup(99m)Tc state is an effective feature in biliary excretion behavior of sup(99m)Tc compounds. Another interesting in vivo behavior of sup(99m)Tc-2-MPG is the difference observed in mice and rabbits: in mice, very high sup(99m)Tc activity is concentrated in the gallbladder and the clearance from tissues other than the gallbladder is rapid, whereas in rabbits, although a rapid and high excretion into the gallbladder is observed, a considerable high sup(99m)Tc activity is retained in the liver and the kidney. One reason for this different in vivo behavior is the low stability of this complex at high dilution: a big animal has the large dilution volume which lead to higher decomposition estimated by the higher liver and kidney retention or the lower bile excretion. In conclusion, studies carried on sup(99m)Tc-2-MPG showed a good biliary excretion behavior but an in vivo unstableness in big animals. (author)

  10. The comparison of Tc99m-pertechnetate/mibi subtraction and double phase Tc99m-mibi techniques in parathyroid imaging

    International Nuclear Information System (INIS)

    Bilkay, Ue.; Erinc, R.; Karapolat, I.; Kumanlioglu, K.

    2001-01-01

    Experienced parathyroid surgeons can localize nearly %90-95 of the abnormal parathyroid glands with total thyroid bed exploration. For this reason, for the first surgical exploration preoperative imaging of the gland could be considered unnecessary. However, localization of the abnormal parathyroid tissue preoperatively could be beneficial in ectopic adenomas which consists %20 of all adenomas and also in shortening surgical procedure in single adenomas with the use of unilateral exploration. Re-exploration after an unsuccessful surgery is the most widely accepted indication for parathyroid imaging. Today, although Tc99m-MIBI is the accepted radionuclide with the advantages of giving better image quality with lower radiation dose over Tl-201, for imaging hyper functioning parathyroid tissue, there is no consensus on the ideal imaging protocol. Single-tracer double-phase imaging (STDP) and dual-tracer subtraction technique (Tc99m-pertechnetate/Tc99m-MIBI) (DTST) are proposed protocols using Tc99m-MIBI. The aim of this ongoing study is; to compare STDP imaging with DTST and to compare sensitivity of pinhole and high resolution parallel hole images in STDP protocol

  11. Localization of primary hyperparathyroidism using 99mTc-MIBI scintigraphy

    International Nuclear Information System (INIS)

    Yane, Katsunari; Emoto, Mie; Okamoto, Hideyuki; Yuki, Kazue; Hosoi, Hiroshi; Miyahara, Hiroshi

    2003-01-01

    To determine the clinical utility of 99mTc-MIBI scintigraphy (MIBI) in the localization of hyperfunctioning parathyroid lesions, detection of lesions in 14 patients with primary hyperparathyroidism was compared between MIBI, ultrasonography and computed tomography (CT). MIBI (85.7%) and ultrasonography (78.5%) demonstrated higher detection rates than CT (50%). Furthermore, combination of MIBI and ultrasonography (92.8%) increased the detection rate. One case of ectopic parathyroid adenoma was detected only on MIBI. The smallest parathyroid lesion detected using MIBI was a parathyroid adenoma weighing 300 mg. A combination of MIBI and ultrasonography is therefore useful for the localization of primary hyperparathyroidism, and MIBI is particularly useful for detecting ectopic lesions. (author)

  12. Diversification of 99Mo/99mTc separation: non–fission reactor production of 99Mo as a strategy for enhancing 99mTc availability.

    Science.gov (United States)

    Pillai, Maroor R A; Dash, Ashutosh; Knapp, Furn F Russ

    2015-01-01

    This paper discusses the benefits of obtaining (99m)Tc from non-fission reactor-produced low-specific-activity (99)Mo. This scenario is based on establishing a diversified chain of facilities for the distribution of (99m)Tc separated from reactor-produced (99)Mo by (n,γ) activation of natural or enriched Mo. Such facilities have expected lower investments than required for the proposed chain of cyclotrons for the production of (99m)Tc. Facilities can receive and process reactor-irradiated Mo targets then used for extraction of (99m)Tc over a period of 2 wk, with 3 extractions on the same day. Estimates suggest that a center receiving 1.85 TBq (50 Ci) of (99)Mo once every 4 d can provide 1.48-3.33 TBq (40-90 Ci) of (99m)Tc daily. This model can use research reactors operating in the United States to supply current (99)Mo needs by applying natural (nat)Mo targets. (99)Mo production capacity can be enhanced by using (98)Mo-enriched targets. The proposed model reduces the loss of (99)Mo by decay and avoids proliferation as well as waste management issues associated with fission-produced (99)Mo.

  13. In vitro studies of leukocyte labeling with /sup 99m/Tc

    International Nuclear Information System (INIS)

    Uchida, T.; Vincent, P.C.

    1976-01-01

    A method for labeling leukocytes in vitro with /sup 99m/Tc is described. Separated leukocytes are incubated with /sup 99m/Tc, followed by reduction with stannous chloride and washing with acid citrate dextrose solution. Maximum labeling occurs after at least 5 min incubation with pertechnetate, followed by at least 10 min incubation with stannous chloride. Labeling is similar at room temperature and at 37 0 C. The labeled leukocytes are viable, and reutilization of label does not occur in vitro. In acid conditions (pH 5.2), the elution of /sup 99m/Tc from leukocytes is comparable with that of 32 P-diisopropylfluorophosphate, but /sup 99m/Tc elution is greater at pH 7.2 to 7.4. Neutrophils label more heavily with /sup 99m/Tc than do monocytes, lymphocytes, erythrocytes, or platelets

  14. Combined Use of Tc-99m MIBI Scan and MRI for Evaluation of Active Lesions in Multiple Myeloma

    International Nuclear Information System (INIS)

    Mititelu, R.; Marinescu, G.; Iriciuc, M.; Rimbu, A.; Ghita, S.; Mazilu, C.; Murgoci, P.; Codorean, I.

    2006-01-01

    uptake (7pts) and a mixed pattern with focal lesions on a generalized diffuse uptake (8pts). 5/29 pts shown a normal uptake of the radiotracer (probably due to over-expression of P glycoprotein). In these patients we found MRI pathologic changes (focal vertebral lesions on different levels). 2/29 pts had no pathologic changes on spine MRI; one of them has shown a pattern of diffuse uptake on the MIBI scan, and the other one has shown focal uptake of MIBI, but not in the spine (ribs and skull). Combined use of spine MRI and MIBI scan results in a sensitivity of 96.66% for detecting pathologic changes and bone marrow involvement. Conclusion: 99mTc MIBI reflects the extent of bone marrow involvement and the activity of the disease. It has the advantage of whole body imaging in one single examination. Combined use of 99mTc-MIBI scan and spine MRI has a greater sensitivity than each method used separately (96.55% vs. 86.75% for MIBI and 89.65% for MRI). (author)

  15. An unusual accumulation of technetium-99m-sestamibi (99mTc-MIBI) mimicking an ectopic hyperfunctioning parathyroid tissue: usefulness of CT/SPECT technology in a single device

    International Nuclear Information System (INIS)

    Kienast, O.; Traub, T.; Dobrozemsky, G.; Dudczak, R.; Kurtaran, A.; Kletzmayr, J.; Kainberger, F.

    2002-01-01

    Full text: 99mTc-MIBI dual phase scintigraphy is a well established imaging modality in detecting hyperfunctioning parathyroid tissue. The authors report a case of 99mTc-MIBI scintigraphy showing MIBI-accumulation in projection of the upper mediastinum suspicious for hyperfunctioning parathyroid tissue. Further anatomical localization achieved by combined CT/SPECT technology revealed no mediastinal mass. A 71-year-old man with renal transplantation following chronic renal failure experienced hypercalcemia, hyperphosphatemia and elevation of serum parathyroid hormone levels. Ultrasonography of the neck revealed no enlarged parathyroid glands and further diagnostic work-up has been performed. A 99mTc-MIBI dual phase scintigraphy showed no abnormal accumulation in the typical parathyroid region but a focal activity in projection of the upper mediastinum was detected. The SPECT imaging of the neck and upper chest showed the accumulation in anterior location. This finding was interpreted as an ectopic (mediastinal) hyperfunctioning parathyroid tissue. In order to localize the focus, a CT/SPECT study with a single device system (GE Medical Systems Millennium VG gamma camera with Hawkeye) was done. This is an imaging system composed of a low current x-ray tube and a set of detectors mounted onto the camera's slip ring gantry. On registered and fused anatomical/functional images (CT/99mTc-MIBI SPECT), the increased accumulation of 99mTc-MIBI was shown to be an accumulation in the upper sternum. Further radiological examination revealed no abnormality in the sternum. This case illustrates the usefulness of the combined CT/SPECT imaging strategy with a single device in preventing unnecessary diagnostic/therapeutic interventions in patients with hyperthyroidism and abnormal 99mTc-MIBI scintigraphy. (author)

  16. Accumulation of Tc-99m-MIBI and Tc-99m-tetrofosmin in tumor cells. Uptake and washout studies

    International Nuclear Information System (INIS)

    Rodrigues, M.; Aghajanian, A.A.; Sinzinger, H.; Kalinowska, W.; Zielinski, C.

    2002-01-01

    Aim: To investigate in-vitro the uptake and washout of Tc-99m-MIBI and Tc-99m-tetrofosmin in human breast adenocarcinoma and soft tissue sarcoma cell lines. Methods: The uptake of Tc-99m-MIBI and Tc-99m-tetrofosmin (at 37 0 C, 10, 30 and 60 minutes after incubation with 7.4x10E5 Bq each tracer) was investigated in breast adenocarcinoma MCF-7 and SK-BR-3 cells, synovial sarcoma SW 982 cells and chondrosarcoma SW 1353 cells (concentration of 1x10E6 cells/ml incubation medium). Tracer uptake in cells incubated with ouabain (Na/K-ATPase pump inhibitor; 100 μM and 1mM; 15 and 30 minutes), nigericin (increases mitochondrial potential and disrupts cell membrane potential; 5 and 50 μg/ml; 15 minutes) and carbonyl cyanide m-chlorophenylhydrazone (CCCP) (depolarizes mitochondrial membrane; 10 and 100 μM; 30 minutes) was compared to that in cells without incubation with chemical agents (control cells). The washout (at 37 0 C, 10-60 minutes, 30 and 60 minutes after tracer incubation) of Tc-99m-MIBI and Tc-99m-tetrofosmin was studied in MCF-7 cells, SK-BR-3 cells , SW 1353 cells and fibrosarcoma SW 684 cells. Results: Cellular tracer uptake decreased with ouabain (decrease of Tc-99m-tetrofosmin > Tc-99m-MIBI in SK-BR-3 cells and SW 982 cells) and increased with nigericin (increase of Tc-99m-MIBI > Tc-99m-tetrofosmin in all cells) as compared to the uptake in control cells. With CCCP, decrease of Tc-99m-MIBI uptake in cells preincubated with nigericin was higher than that in cells under basal conditions, whereas a similar decrease of Tc-99m-tetrofosmin uptake in these two group of cells was found. Washout of Tc-99m-MIBI from all cells was lower than that of Tc-99m-tetrofosmin. No significant difference in cell-associated activity of both tracers was found between washout after 30 minutes and that after 60 minutes of incubation, in all cells. Washout of Tc-99m-MIBI from SK-BR-3 cells Tc-99m-tetrofosmin) and Na/K-ATPase pump (Tc-99m-tetrofosmin > Tc-99m-MIBI). Tc-99m-MIBI and

  17. The clinical use of myocardial gated SPECT imaging with 99TcmN-NOEt

    International Nuclear Information System (INIS)

    Li Sijin; Hu Guang; Liu Jianzhong; Tian Mei; Li Xianfeng; Zhang Wanchun; Wang Jin

    2002-01-01

    Objective: To evaluate the clinical value of 99 Tc m N-NOEt myocardial perfusion imaging comparing with 99 Tc m -MIBI. Methods: Twenty patients (pts) were divided into 2 groups. Group 1 (G1), left ventricular ejection fraction (LVEF) ≥ 50%, 13 pts, the mean age was (49.9 +- 14.7) years. Group 2 (G2), LVEF 0.05 vs G1). All the pst underwent gated SPECT imaging at 30 and 120 min after injection of 925 MBq 99 Tc m N-NOEt at rest, and the heart to lung (H/L) activity ratio was calculated. Of the 6 pts in G2 and 1 pt in G1 underwent the 99 Tc m -MIBI imaging within 3 days to the former imaging at 120 min after 99 Tc m -MIBI injection under the same condition as at 99 Tc m N-NOEt imaging. The left ventricles of the 7 pts were divided into 63 segments with 9 segments for each, and the four-point scoring system was used to evaluate the tracer uptake in the segments. Results: The H/L ratio was 1.47 +- 0.47 and 1.59 +- 0.53 (P > 0.50) respectively in G1 and was 0.72 +- 0.11 and 0.89 +- 0.11 (P 99 Tc m N-NOEt and 99 Tc m -MIBI for the presence of defects was 93.65%, Kappa +- s = 0.87 +- 0.12. The mean score was 2.0 +- 0.84 (MIBI) and 2.38 +- 0.84 (NOEt) respectively (P > 0.05). Conclusions: 1) If the lung uptake of 99 Tc m N-NOET showed higher, it suggested that the left ventricular function was poor. 2) The results of LVEF, EDV and ESV were accordant between MIBI and NOEt. 3) The extent and intensity of myocardial defect with NOEt imaging was more severe than that with MIBI

  18. The Clinical usefulness of {sup 99mT}c HMPAO Leukocyte/{sup 99mT}c phytate bone marrow scintigraphy for diagnosis of prosthetic knee infection: A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Kyung Pyo; Park, Ji Sun; Lee, Ah Young; Choi, Su Jung; Lee, Seok Mo; Bae, Sang Kyun [Inje Univ., Pusan Paik Hospital, Pusan (Korea, Republic of)

    2012-12-15

    The preferred radionuclide imaging procedure for diagnosing prosthetic joint infection is combined radiolabeled leukocyte/{sup 99mT}c sulfur colloid bone marrow scintigraphy, which has an accuracy of over 90%. Unfortunately, sulfur colloid is no longer available in South Korea. in this study, we evaluated the usefulness of {sup 99mT}c phytate, a substitute for {sup 99mT}c sulfur colloid, when combined with radiolabeled leukocyte scintigraphy in suspected prosthetic knee infections. Eleven patients (nine women, two men; mean age 72{+-}6 years) with painful knee prostheses and a suspicion of infection underwent both {sup 99mT}c phytate bone marrow scintigraphy (BMS). The combined images were interpreted as positive for infection when radioactivity in the LS at the sits of clinical interest clearly exceeded that of the BMS (discordant); they were interpreted as negative when the increased activity in the LS was consistent with an increased activity in the BMS(concordant). The final diagnosis was made with microbiological or intraoperative findings and a clinical follow up of at least 12 months. Five of eleven patients were diagnosed as having an infected prosthesis. The overall sensitivity, specificity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of the combined LS/BMS were 100%, 83%, 83%, 100% and 91%, respectively. We find that combined {sup 99mT}c HMPAO LS/{sup 99mT}c phytate BMS shows comparable diagnostic performance to other studies utilizing sulfur colloid. Combined {sup 99mT}c HMPAO LS/{sup 99mT}c phytate BMS is therefore expected to be an acceptable alternative to combined radiolabeled LS/{sup 99ms}ulfur colloid BMS for diagnosing prosthetic knee infections.

  19. Hürthle cell tumor dwelling in hot thyroid nodules: preoperative detection with technetium-99m-MIBI dual-phase scintigraphy.

    Science.gov (United States)

    Vattimo, A; Bertelli, P; Cintorino, M; Burroni, L; Volterrani, D; Vella, A; Lazzi, S

    1998-05-01

    Single injection dual-phase scintigraphy (early and late acquisitions) with 99mTc-MIBI was used to differentiate benign and malignant hot thyroid nodules. Thirteen euthyroid and two hyperthyroid patients displaying a hot thyroid nodule on the 99mTc scan due to an autonomously functioning thyroid nodule (AFTN) underwent early (15-30 min) and late (3-4 hr) thyroid scintigraphy after the administration of 740-1000 MBq 99mTc-MIBI. Visual scoring was done to assess nodular tracer uptake and retention. In addition, the nodular-to-thyroid (N/T) uptake ratio in the early and late image and the washout rates (WO) from the nodule and thyroidal tissue were measured. All patients underwent thyroid surgery. Histopathology revealed a Hürthle cell tumor in three nodules, a benign adenoma with oxyphilic metaplasia in two nodules and a benign adenoma without oxyphilic cells in the remaining 10 nodules. The Hürthle cell tumor nodules displayed intense and persistent uptake of 99mTc-MIBI (N/T was 2.81 +/- 0.52 and 5.53 +/- 1.06 in early and late images, respectively; WO from the nodule was 12.33 +/- 0.47, WO from the thyroidal tissue was 22.00 +/- 3.56). The benign nodules showed intense uptake in the early image and intense uptake to absent retention in the late image (N/T was 2.94 +/- 1.31 and 1.62 +/- 0.50 in the early and late images, respectively; WO from the nodule was 20.25 +/- 2.92, WO from the thyroidal tissue was 20.33 +/- 2.92). Single injection dual-phase 99mTc-MIBI scintigraphy of the thyroid with AFTN can identify nodules as a result of the activity of a Hürthle cell tumor, since these tumors cause intense and persistent tracer uptake in contrast with a benign AFTN.

  20. Role of 99mTc labelled GHA in post treatment evaluation of brain tumours

    International Nuclear Information System (INIS)

    Choudhury, P.

    2003-01-01

    Full text: Introduction: Biochemical investigations have a major role to play in the management of primary brain tumours. It is well known that major biochemical changes occur during cancerous transformation including changes in the energy metabolism of the cell. Changes take place in terms of utilization of glucose and other substrates, protein synthesis and expression of antigens and receptors. Changes also take place in disruption of transport mechanisms across cell membranes and other physiological boundaries like blood brain barrier. In the management of primary brain tumours positron emitting tracers have an undisputed role and the role of cationic tracers like Thallium-201, 99m-Tc MIBI and 99m-Tc tetrofosmin has been cited as an alternative to positron tracers in neuro oncology. It must be borne in mind that the cationic tracers are expensive to procure and facilities for positron emission tomography are not available in most of the developing countries. Tc-99m GHA Brain Imaging: Keeping in view the above, a cheaper alternative for PET radio tracers was evaluated. We have so far conducted more than 100 brain SPECT studies, using Tc-99m Glucoheptonic acid (GHA), in 60 patients of brain tumour, both at the time of their diagnosis, as well as after treatment during the follow-up period. Tc-99m Glucoheptonic acid (GHA) is a chemical glucose analogue. Avid concentration of the radiopharmaceutical was noted in viable tumor tissue in the SPECT images done one hour after injection of 740 MBq of 99m-Tc GHA. This was subsequently confirmed by histopathological examination in patients undergoing re-surgery for residual disease or follow up and clinical correlation in patients under remission. Avid tracer concentration was also well demonstrated in recurrent disease (proven by clinical examination, histopathology and/or magnetic resonance imaging (MRI). No significant tracer uptake was seen in areas of radiation induced necrosis. Non-specific uptake in the tumor bed was

  1. Evaluation of parathyroid imaging methods with {sup 99m}Tc-MIBI. The comparison of planar images obtained using a pinhole collimator and a parallel-hole collimator

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Hirofumi; Iwasaki, Ryuichiro; Hashimoto, Jun; Nakamura, Kayoko; Kunieda, Etsuo; Sanmiya, Toshikazu; Kubo, Atsushi [Keio Univ., Tokyo (Japan). School of Medicine; Ogawa, Koichi; Inagaki, Kazutoshi

    1999-07-01

    Parathyroid scintigraphy with {sup 99m}Tc-MIBI was performed using two kinds of collimators, namely, a pinhole one and a parallel-hole one, to evaluate which one was more suitable for the detection of hyperfunctioning parathyroid lesions. In the studies using {sup 99m}Tc source, the pinhole collimator showed better efficiency and spatial resolution in the distance where the parathyroid scan are actually performed. In the phantom study, the nodular activities modeling parathyroid lesions were visualized better on the images obtained using the pinhole collimator. In clinical studies for 30 patients suspicious of hyperparathyroidism, hyperfunctioning parathyroid nodules were better detected when the pinhole collimator was used. In conclusion, the pinhole collimator was thought to be more suitable for parathyroid scintigraphy with {sup 99m}Tc-MIBI than the parallel-hole collimator. (author)

  2. 99 mTc-MIBI washout as a complementary factor in the evaluation of idiopathic dilated cardiomyopathy (IDCM) using myocardial perfusion imaging.

    Science.gov (United States)

    Shiroodi, Mohammad Kazem; Shafiei, Babak; Baharfard, Nastaran; Gheidari, Mohammad Esmail; Nazari, Babak; Pirayesh, Elaheh; Kiasat, Ali; Hoseinzadeh, Samaneh; Hashemi, Abolghassem; Akbarzadeh, Mohammad Ali; Javadi, Hamid; Nabipour, Iraj; Assadi, Majid

    2012-01-01

    Rapid technetium-99 m methoxyisobutylisonitrile (99 mTc-MIBI) washout has been shown to occur in impaired myocardia. This study is based on the hypothesis that scintigraphy can be applied to calculate the myocardial 99 mTc-MIBI washout rate (WR) to diagnose and evaluate heart failure severity and other left ventricular functional parameters specifically in idiopathic dilated cardiomyopathy (IDCM) patients. Patients with IDCMP (n = 17; 52.65 ± 11.47 years) and normal subjects (n = 6; 49.67 ± 10.15 years) were intravenously administered 99 mTc-hexakis-2-methoxyisobutylisonitrile (99 mTc-MIBI). Next, early and delayed planar data were acquired (at 3.5-h intervals), and electrocardiogram (ECG)-gated myocardial perfusion single photon emission computed tomography (SPECT) was performed. The 99 mTc-MIBI WR was calculated using early and delayed planar images. Left ventricular functional parameters were also analyzed using quantitative gated SPECT (QGS) data. In target group, myocardial WRs (29.13 ± 6.68%) were significantly higher than those of control subjects (14.17 ± 3.31%; P 99 mTc-MIBI WR increased with the increasing severity of the NYHA functional class (23.16 ± 1.72% for class I, 30.25 ± 0.95% for class II, 32.60 ± 6.73% for class III, and 37.50 ± 7.77% for class IV; P = 0.02). The WR was positively correlated with the end-diastolic volume (EDV) index (r (2) = 0.216; β = 0.464; P = 0.02 [ml/m(2)], the end-systolic volume (ESV) index (r (2) = 0.234; β = 0.484; P = 0.01 [ml/m(2)]), the summed motion score (SMS) (r (2) = 0.544; β = 0.738; P = 0.00), and the summed thickening score (STS) (r (2) = 0.656; β = 0.810; P = 0.00); it was negatively correlated with the left ventricular ejection fraction (LVEF) (r (2) = 0.679; β = -0.824; P = 0.00). It can be concluded that 99 mTc-MIBI scintigraphy might be a valuable molecular imaging tool for the diagnosis and evaluation of myocardial damage or dysfunction severity.

  3. Clinical importance of technetium-99m-methoxyisobutylisonitrile (MIBI) scintigraphy in differentiated thyroid carcinoma patients with elevated thyroglobulin levels and negative I-131 scanning results

    International Nuclear Information System (INIS)

    Kuecuek, N.O.; Kulak, H.A.; Aras, G.

    2006-01-01

    The aim of this study was to evaluate the potential contribution of Tc-99m-MIBI scintigraphy to the follow-up of patients with differentiated thyroid carcinoma, who had elevated Tg levels and negative I-131 whole-body scan (WBS) results. In this retrospective study, we evaluated 28 patients with differentiated thyroid carcinoma, who had total or near total thyroidectomy followed by an ablative dose of I-131 at various time intervals (15 women, 13 men; mean age 43±17 years). All patients were treated with T4 suppression. After a mean follow-up period of 6.1 years (range 3-15) all patients were determined to have a high serum Tg concentrations (>2 ng/ml) and previous negative I-131 WBS results. All patients were examined for metastatic sites using Tc-99m-MIBI scan. Scans were visually evaluated for detecting lymph node metastases and/or local recurrence, lung metastases and skeletal metastases. Tc-99m-MIBI scan demonstrated lesions in 23 patients (83.3%). In five patients with negative Tc-99m-MIBI scan findings (FN results): Chest CT showed small-sized mediastinal LN metastases in 2 patients and lung metastases in another 2 patients (<1 cm); Neck CT showed small-sized cervical LN involvement in 1 patient. The sensitivity of detection for neck was 94.4%, for lung 63.6%, and for bone lesions 100%. For all scan sites taken together, the sensitivity of disease detection was 83.3%, the specificity was 50%, positive predictive value (PPV) was 96.2%, and finally negative predictive value (NPV) was 16.7%. We concluded that Tc-99m-MIBI scan should be considered as a supplementary scintigraphic method for the follow-up of patients with high serum Tg levels and negative I-131 WBS results, and it can help clinicians in making the decision to treat these patients. (author)

  4. Assessment of the direct cyclotron production of (99m)Tc: An approach to crisis management of (99m)Tc shortage.

    Science.gov (United States)

    Rovais, Mohammad Reza Aboudzadeh; Aardaneh, Khosro; Aslani, Gholamreza; Rahiminejad, Ali; Yousefi, Kamran; Boulouri, Fatemeh

    2016-06-01

    Nowadays, the cyclotron production of technetium-99m ((99m)Tc) has been increased, due to the worldwide (99m)Tc generator shortage. In the present work, an improved strategy for the production of (99m)Tc, using the proton irradiation of the enriched (100)Mo was developed. The performance of this method in terms of the production yield, chemical purity, radiochemical purity, as well as radionuclide purity was evaluated. The average production yield was measured to be 356MBqμA(-1)h(-1). A good agreement was found between the calculated production yield and the experimental one. The radiochemical separation and total recovery yields of (99m)Tc were 92% and 69%, respectively. The radiochemical and the radionuclide purities of the (99m)Tc were 99% and >99.99% at the end of purification, respectively. The results of quality control tests (QC) support the concept that cyclotron-produced (99m)Tc is suitable for preparation of USP-compliant. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Preoperative localization of enlarged parathyroid glands by 99mTc-MIBI scintigraphy

    International Nuclear Information System (INIS)

    Fujimoto, Nobumasa; Itoh, Kiichiro; Kishikawa, Hidehumi; Tohda, Akira; Takaha, Natsuki; Kobayashi, Yoshiyuki; Nakamori, Shigeru; Sagawa, Shiro; Sonoda, Takao

    1997-01-01

    From June 1994 to September 1996, 24 patients with biochemical confirmation of hyperparathyroidism were studied with 99m Tc-MIBI scintigraphy prior to operation. Eleven patients had primary hyperparathyroidism (PHPT) and 13 had secondary hyperparathyroidism (SHPT) associated with chronic renal failure, including one patient with recurrent disease after subtotal parathyroidectomy. A positive 99m Tc-MIBI scan for an enlarged gland was defined as an area of persistent focal uptake on the delayed image acquired at 150 min after intravenous injection of 600 MBq of 99m Tc-MIBI. Of 11 patients with PHPT, 10 were found to have solitary parathyroid adenomas at surgery and one patient had primary hyperplasia. 99m Tc-MIBI scintigraphy accurately detected 9 of 10 adenomas and 2 of 3 hyperplastic glands with no false positive results. Both of the two glands that were not detected by 99m Tc-MIBI weighted 200 mg. The mean weight of the 11 glands that were visualized was 1264 mg. The sensitivity and predictive value positive for PHPT were 84.6% and 100%, respectively. In 13 patients with SHPT, all of 49 parathyroid glands were identified during surgery, with 43 hyperplastic glands and 6 normal-size glands. Of 43 hyperplastic glands, 28 were detected by 99m Tc-MIBI and there was significant difference between the mean weight of these 28 glands and that of the 15 nonimaged hyperplastic glands. None of the six normal glands were imaged with 99m Tc-MIBI. One patient had a false positive scan caused by a thyroid nodule. The sensitivity and predictive value positive for SHPT were 65.1% and 96.6%, respectively. (K.H.)

  6. First experience of brain tumour scintigraphy with 99mTc-MIBI before and after surgery

    International Nuclear Information System (INIS)

    Jurkiene, N.; Kulakiene, I.; Aleksandrovas, D.; Tamasauskas, A.

    2004-01-01

    Full text: Morphological imaging techniques like computed tomography and magnetic resonance imaging are routinely used to localize tumours. However, their use for prediction of histopathological diagnosis and tumour changes after treatment is difficult. Functional imaging using positron emission tomography and single photon emission computed tomography (SPECT) were introduced as non-invasive methods for the differentiation and evaluation of brain tumours, especially for their follow-up. The purpose of present study was to investigate the uptake of 99mTc-MIBI in case of malignant brain tumours before and after surgery. 25 patients (13 males and 12 females; age range 21-75 years; average age 48.76±17.25 years) with brain tumours were investigated. The histological diagnoses of the tumours were confirmed from surgical specimens. None of the patients had received any treatment before enrolment for the study. 99mTc-MIBI brain SPECT was performed 3.88±2.85 days before surgery and 9.88±2.24 days after surgery in all cases. SPECT scans were acquired in 64 projections over 360 deg. using a dual-head gamma camera (Siemens E.Cam) coupled with low energy collimator, 15 minutes after intravenous injection of 550 MBq 99mTc-MIBI. Data were recorded in a 64x64 matrix at a zoom factor of 1.78. SPECT images were reconstructed and analysed in the transversal, axial and coronal planes. The study results are presented in the table. Of the 25 tumors, only 19, majority glioblastoma (11) showed avid uptake in the pre- surgery scan. Tumors, II0 astrocytoma (1), oligoasrtrocytoma (1), III0 astrocytoma (3) were missed in the pre surgery scan. Comparison of pre- and postoperative images showed the reduction of 99mTc-MIBI uptake post-operatively except in one case of gliosarcoma where the uptake increased after surgery. In one case of III deg. astrocytoma the 99mTc-MIBI uptakes was observed only after the surgery. All post-operative images showed more intensive uptake in the scalp (zone of

  7. Usefulness of 99mTc MIBI scintigraphy in hyperparathyroidism. A retrospective analysis of the surgical patients

    International Nuclear Information System (INIS)

    Nakamura, Toshiyuki; Kobayashi, Shinya; Fujimori, Minoru

    1998-01-01

    In patients who receive surgery for primary or secondary hyperparathyroidism, preoperative diagnosis of the location of the parathyroid glands is important. Ninety-nine-m Technetium methoxyisobutylisonitrile (MIBI) accumulates in the pathological parathyroid. We used MIBI scintigraphy to detect diseased parathyroid glands in 20 patients with hyperparathyroidism, and successfully located the glands in seventeen. The accuracy of MIBI scintigraphy (100%) is significantly (p<0.05) better than that of Thallium-Technetium subtraction scintigraphy (56%). In a patient with hyperparathyroidism due to an ectopic parathyroid gland, MIBI scintigraphy showed accumulation in a mediastinal gland. MIBI scintigraphy is thus useful for gland location in hyperparathyroidism. (author)

  8. 99Tcm-MIBI hepatobiliary scintigraphy in peadiatric patients with severe cholestatic infant hepatitis syndrome

    International Nuclear Information System (INIS)

    Chen Guibing; Huang Jinxiong; He Xiaojiang; Luo Zuoming; Lu Zhengyuan; Wu Hua

    2010-01-01

    Objective: Because of the limited of 99 Tc m -diethyl iminodiacetic acid ( 99 Tc m -EHIDA) hepatobiliary scintigraphy in the diagnosis of severe cholestatic infant hepatitis syndrome, trial use 99 Tc m -methoxy isobutyl isonitrile ( 99 Tc m -MIBI) as a new hepatobiliary scintigraphy imaging agent to understand its applied basis and primary evaluate value in diagnosis of severe cholestatic infant hepatitis syndrome. Methods: constructed choledochal atresia animal model and investigated the application basis of 99 Tc m -MIBI hepatobiliary scintigraphy. Twenty-seven children patients of severe cholestatic who finally confirmed infant hepatitis syndrome were underwent firstly 99 Tc m -EHIDIA hepatobiliary scintigraphy. After 24 h delay imaging next day, 99 Tc m -MIBI hepatobiliary scintigraphy was underwent after 1 h. Two imaging agents of value in the diagnosis of severe cholestatic infant hepatitis syndrome were compared. Results: It was proved that 99 Tc m -MIBI was surely excreted by hepatobiliary and had no intestinal autocrine phenomenon in animal test. So 99 Tc m -MIBI can be used to undergo hepatobiliary scintigraphy. The sensitivity of 99 Tc m -MIBI hepatobiliary scintigraphy in the diagnosis of severe cholestatic infant hepatitis syndrome was 100% in our primary clinical study. Its sensitivity was higher than which of 99 Tc m -EHIDA hepatobiliary scintigraphy (66.67%) by far. Conclusion: With regard to those children patients who suspected highly severe cholestatic infant hepatitis syndrome in clinical, the sensitivity of 99 Tc m -MIBI hepatobiliary scintigraphy is obviously superior to conventional 99 Tc m -EHIDA hepatobiliary scintigraphy. (authors)

  9. Possibilities of 99mTc-MIBI for imaging of the thyroid parenchyma

    International Nuclear Information System (INIS)

    Mluchkov, N.; Mluchkov, Kh.

    1998-01-01

    Thyroid parenchyma imaging is very important as an evidence of residual part of the gland in case of thyroidectomy. The determination of the mass of this part and its function is crucial at the substituting hormonal therapy. Also at cases of thyroid carcinomas the differential diagnosis of recurrences of radiation and/or postoperative fibrosis is difficult. The thyroid imaging by 131 I and by 99m Tc-pertechnetates is not always possible because of gland blockage from medicines, thyroid hormones and foods with high iodine content. The aim of this study was to establish if 99m Tc-MIBI could depict the thyroid parenchyma without being influenced by gland blockage giving a real image of it. A comparative scintigraphic study has been carried out at 58 patients with different thyroid diseases using 99m Tc-pertechnetate, 131 I and 99m Tc-MIBI. There were 17 patients with diffuse goiter, 27 with nodules (23 of normal activity and 4 with cold nodules), 3 patients with retrosternal goiter and 11 with thyroid carcinoma after surgery intervention. The visualization of the thyroid parenchyma with 99m Tc-MIBI was better than that with 99 0 m Tc-pertechnetate and no dependent on suppression of the gland. All nodules showed 99m Tc-MIBI uptake with the same intensity as the surrounding normal gland tissue. The scintigraphy with 99m Tc-MIBI was of no value for differential diagnosis of nodules. 99m Tc-MIBI scintigraphy could be successfully applied at patients with retrosternal thyroid goiter and for detecting a thyroid rest at patients with thyroid cancer after surgery intervention. (author)

  10. Peptic ulcer imaging with /sup 99m/Tc sucralfate and possible advantages of /sup 99m/Tc sucrose octasulfate

    International Nuclear Information System (INIS)

    CentiColella, A.; Scopinaro, F.

    1986-01-01

    Sucralfate is a basic aluminum salt of sucrose octasulfate that protects the damaged mucosa and also the normal mucosa from peptic aggression. In fact sucralfate adheres to the mucosa as pH decreases below 4, and buffers the acid, slowly releasing sucrose octasulfate that forms insoluble complexes with the proteins exuded by the ulcers, or is washed out of the stomach. Sucralfate itself is also able to precipitate with proteins in the ulcers. Sucralfate may be labelled by several methods: /sup 99m/Tc HSA, /sup 99m/Tc DTPA, /sup 75/Se, /sup 111/In. The aims of this study were to evaluate the clinical results obtained using /sup 99m/Tc DTPA sucralfate, which the authors believe is the only labelled sucralfate suitable for clinical studies and to discuss the possible diagnostic uses of /sup 99m/Tc sucrose octasulfate. In fact, it has been possible to label the sucrose octasulfate either with /sup 99m/Tc DTPA or with /sup 99m/Tc without the use of intermediate ligands

  11. 99mTc-MIBI-SPECT-studies in the evaluation of brain tumors

    International Nuclear Information System (INIS)

    Ambrus, E.; Pavics, L.; Gruenwald, F.; Barath, B.; Tiszlavicz, L.; Bender, H.; Menzel, C.; Almasi, L.; Lang, J.; Bodosi, M.; Biersack, H.J.; Csernay, L.

    1994-01-01

    Brain SPECT studies were performed 5 and 60 minutes after 99m Tc-MIBI administration in 41 patients with brain tumors confirmed by CT and surgical removal (13 meningeomas, 8 astrocytomas grades I-III, 10 glioblastomas, 10 metastases). 99m Tc-MIBI uptake was found in 32 out of 41 brain tumors. According to the semiquantitative SPECT analysis, the tumor/non tumor radios revealed a statistically significant difference in the early tracer uptake between meningeomas and astrocytomas (+4.73±2.91 vs -1.75±0.75, p 99m Tc-MIBI uptake and its changes with time. We concluded that the combination of an early and late 99m Tc-MIBI brain SPECT may be helpful in the non invasive histological classification of brain tumors and the determination of the grade of theirs malignancy. (orig.) [de

  12. Rapid gated Thallium-201 perfusion SPECT - clinically feasible?

    International Nuclear Information System (INIS)

    Wadhwa, S.S.; Mansberg, R.; Fernandes, V.B.; Wilkinson, D.; Abatti, D.

    1998-01-01

    Full text: Standard dose energy window optimised Thallium-201 (Tl-201) SPECT has about half the counts of a standard dose from Technetium-99m Sestamibi (Tc99m-Mibi) gated perfusion SPECT. This study investigates the clinical feasibility of rapid energy window optimised Tl-201 gated perfusion SPECT (gated-TI) and compares quantitative left ventricular ejection fraction (LVEF) and visually assessed image quality for wall motion and thickening to analogous values obtained from Tc99m-Mibi gated perfusion SPECT (gated - mibi). Methods: We studied 60 patients with a rest gated Tl-201 SPECT (100 MBq, 77KeV peak, 34% window, 20 sec/projection) followed by a post stress gated Sestamibi SPECT (1GBq, 140KeV, 20% window, 20 sec/projection) separate dual isotope protocol. LVEF quantitation was performed using commercially available software (SPECTEF, General Electric). Visual grading of image quality for wall thickening and motion was performed using a three-point scale (excellent, good and poor). Results: LVEF for gated Tl-201 SPECT was 59.6 ± 12.0% (Mean ± SD). LVEF for gated Sestamibi SPECT was 60.4 ±11.4% (Mean ± SD). These were not significantly different (P=0.27, T-Test). There was good correlation (r=0.9) between gated-TI and gated-mibi LVEF values. The quality of gated-Tl images was ranked as excellent, good and poor in 12, 50 and 38% of the patients respectively. Image quality was better in gated-mibi SPECT, with ratings of 12, 62 and 26% respectively. Conclusion: Rapid gated Thallium-201 acquisition with energy window optimisation can be effectively performed on majority of patients and offers the opportunity to assess not only myocardial perfusion and function, as with Technetium based agents, but also viability using a single day one isotope protocol

  13. Comparison of Tc-99m-tetrofosmin and Tc-99m-MIBI scintimammography in differential diagnosis of breast mass

    International Nuclear Information System (INIS)

    Park, Jung Mi; Choi, Joon Young; Lee, Kyung Han; Choi, Yong; Choe, Yearn Seong; Kim, Sang Eun; Kim, Byung Tae; Nam, Seok Jin; Yang, Jeong Hyun

    2000-01-01

    Tc-99m-MIBI (MIBI) and Tc-99m-Tetrofosmin (TF) are commonly used for scintimammog (SMM). We compared the diagnostic ability of SMM using Tc-99m-MIBI and Tc-99m-TF for the differ diagnosis of breast mass. The study subjects were comprised of 123 breast lesior 86 normal breasts of 114 patients who underwent SMM. Bilateral prone images and anterior supine images obtained at 5 minutes and 1 or 3 hours after intravenous injection of 740 MBq of either MIBI or TF. of tumors were not significantly different between the MIBI and TF groups. First, two observers independ read the SMM without clinical information (1st interpretation), then read again with information about location (2nd interpretation). Sensitivity and specificity of each radiopharmaceutical for the diagnosis of cancer were evaluated in terms of image acquisition time, tumor size, and location. The SMM sb a good agreement between two observers for 1st and 2nd interpretation, except for TF SMM at hr. For first interpretation, the sensitivities at 5 min, 1 hr, and 3 hr were not significantly different between MIE TF SMM (81.6%, 80.0%, 60.9% in MIBI vs. 88.9%, 80.6%, 42.9% in TF), although the sensitivities of images were significantly lower than 5 min images in both MIBI and TF SMM. The specificity of TF at was superior to that of MIBI (81.5%, 90.0%, 82.9% in MIBI vs. 96.7%, 100%, 90.0% in TF, p<0.01 MB TF at 5 min). For the second interpretation with information of mass location, the sensitivities at 3 hr in were significantly lower than 5 min images (86.8%, 86.7%, 78.3% in MIBI vs. 88.9%, 93.5%, 57.1% in between MIBI and TF SMM. However, there was no significant difference in the specificity (60.0%, 5 75.0% for MIBI vs. 86.7%, 100%, 100% for TF). MIBI and TF SMM showed lower sensitivities for the t with less than 1 cm than tumors with more than 1 cm. However, the location of tumors did not influence sensitivity and specificity between MIBI and TF SMM. The ability for the differential diag of breast tumor is

  14. Evaluation of breast MIBI-Tc 99 m scintigraphy for the detection of breast cancer

    International Nuclear Information System (INIS)

    Loriaux, C.; Baeyens, L.; Paternot, J.; Martin, P.; Verhas, M.

    1997-01-01

    Full text. The aim of the work was to appreciate the contribution of MIBI-Tc 99 m scintigraphy for the detection of breast cancer and to situate this procedure in comparison with mammography 5 (X-ray M) and echography (E C). 21 patients presenting suspected lesion on clinical evaluation/or mammography were referred to the department for breast MIBI-Tc 99 m scintigraphy. 10 min after IV injection of MIBI-Tc 99 m 3 planar scan were realized with a present time of 10 min. The whole investigation including X-ray and surgical procedures were performed within 15 days. The pathologic findings were: 21 malignant lesion (18 canal cancers, 3 lobular cancers), 4 benign lesions (1 fibroadenoma, 2 granuloma, 1 fibrocystic disease). Lesions were bilateral in 3 cases and there was 1 bifocal lesion. 17 tumours were palpable and 8 not palpable, 10 lesion were 2,5 cm (24%). The overall sensitivity and specificity for MIBI-Tc 99 m were 67% and 75% respectively. For the group of palpable tumours, sensitivity of MIBI-Tc 99 m was 86%. In three cases, the X-ray M was difficult to interpret, the MIBI-Tc 99 m was true positive. In 3 false positive X-ray M procedures, the scintigraphy was true negative but, whatever the size of the tumor the best sensitivity was obtained with X-ray M (71%) and E C (70%) while for MIBI Tc-99 m, sensitivity was less (67%). MIBI-Tc 99 m appears to be a complementary tool in cases of difficulty of interpretation of mammography particularly in case of recurrence of the disease

  15. 99mTc renal tubular function agents: Current status

    International Nuclear Information System (INIS)

    Eshima, D.; Fritzberg, A.R.; Taylor, A. Jr.

    1990-01-01

    Orthoiodohippuric (OIH) acid labeled with 131I is a widely used renal radiopharmaceutical agent and has been the standard radiopharmaceutical agent for the measurement of effective renal plasma flow (EPRF). Limitations to the routine clinical use of 131I OIH are related to the suboptimal imaging properties of the 131I radionuclide and its relatively high radiation dose. 123I has been substituted for 131I; however, its high cost and short shelf-life have limited its widespread use. Recent work has centered on the development of a new 99mTc renal tubular function agent, which would use the optimal radionuclidic properties and availability of 99mTc and combine the clinical information provided by OIH. The search for a suitable 99mTc renal tubular function agent has focused on the diamide dithiolate (N2S2), the paraaminohippuric iminodiacetic acid (PAHIDA), and the triamide mercaptide (N3S) donor ligand systems. To date, the most promising 99mTc tubular function agent is the N3S complex: 99mTc mercaptoacetyltriglycine (99mTc MAG3). Studies in animal models in diuresis, dehydration, acid or base imbalance, ischemia, and renal artery stenosis demonstrate that 99mTc MAG3 behaves similarly to 131I OIH. A simple kit formulation is available that yields the 99mTc MAG3 complex in high radiochemical purity. Studies in normal subjects and patients indicate that 99mTc MAG3 is an excellent 99mTc renal tubular agent, but its plasma clearance is only 50% to 60% that of OIH. In an effort to develop an improved 99mTc renal tubular function agent, changes have been made in the core N3S donor ligand system, but to date no agent has been synthesized that is clinically superior to 99mTc MAG3. 61 references

  16. A review of sup(99m)Tc generator technology

    International Nuclear Information System (INIS)

    Molinski, V.J.

    1982-01-01

    The sup(99m)Tc generator has found widespread use because it is ideally suited for scintigraphy. The preparation of sup(99m)Tc generators using alumina and other ion exchange systems is described. Other methods of separating 99 Mo and sup(99m)Tc, such as solvent extraction and sublimation, are also discussed. Some of the problems associated with the alumina column type sup(99m)Tc generator are listed with possible causes and solutions to their problems. The current biomedical applications of the sup(99m)Tc radioisotope are the basis of a $100 million nuclear medicine business. The importance of the sup(99m)Tc generator makes it imperative that we understand and solve the problems associated with its manufacture. (author)

  17. Limitations of Tc99m-MIBI-SPECT imaging scans in persistent primary hyperparathyroidism.

    Science.gov (United States)

    Witteveen, Janneke E; Kievit, Job; Stokkel, Marcel P M; Morreau, Hans; Romijn, Johannes A; Hamdy, Neveen A T

    2011-01-01

    In primary hyperparathyroidism (PHPT) the predictive value of technetium 99m sestamibi single emission computed tomography (Tc99m-MIBI-SPECT) for localizing pathological parathyroid glands before a first parathyroidectomy (PTx) is 83-100%. Data are scarce in patients undergoing reoperative parathyroidectomy for persistent hyperparathyroidism. The aim of the present study was to determine the value of Tc99m-MIBI-SPECT in localizing residual hyperactive parathyroid tissue in patients with persistent primary hyperparathyroidism (PHPT) after initial excision of one or more pathological glands. We retrospectively evaluated the localizing accuracy of Tc99m-MIBI-SPECT scans in 19 consecutive patients with persistent PHPT who had a scan before reoperative parathyroidectomy. We used as controls 23 patients with sporadic PHPT who had a scan before initial surgery. In patients with persistent PHPT, Tc99m-MIBI-SPECT accurately localized a pathological parathyroid gland in 33% of cases before reoperative parathyroidectomy, compared to 61% before first PTx for sporadic PHPT. The Tc99m-MIBI-SPECT scan accurately localized intra-thyroidal glands in 2 of 7 cases and a mediastinal gland in 1 of 3 cases either before initial or reoperative parathyroidectomy. Our data suggest that the accuracy of Tc99m-MIBI-SPECT in localizing residual hyperactive glands is significantly lower before reoperative parathyroidectomy for persistent PHPT than before initial surgery for sporadic PHPT. These findings should be taken in consideration in the preoperative workup of patients with persistent primary hyperparathyroidism.

  18. Bone marrow uptake of 99mTc-MIBI in patients with multiple myeloma

    International Nuclear Information System (INIS)

    Fonti, R.; Del Vecchio, S.; Zannetti, A.; Di Gennaro, F.; Pace, L.; Salvatore, M.; De Renzo, A.; Catalano, L.; Califano, C.; Rotoli, B.

    2001-01-01

    In a previous study, we showed the ability of technetium-99m methoxyisobutylisonitrile ( 99m Tc-MIBI) scan to identify active disease in patients with multiple myeloma (Eur J Nucl Med 1998; 25: 714-720). In particular, a semiquantitative score of the extension and intensity of bone marrow uptake was derived and correlated with both the clinical status of the disease and plasma cell bone marrow infiltration. In order to estimate quantitatively 99m Tc-MIBI bone marrow uptake and to verify the intracellular localization of the tracer, bone marrow samples obtained from 24 multiple myeloma patients, three patients with monoclonal gammopathy of undetermined significance (MGUS) and two healthy donors were studied for in vitro uptake. After centrifugation over Ficoll-Hypaque gradient, cell suspensions were incubated with 99m Tc-MIBI and the uptake was expressed as the percentage of radioactivity specifically retained within the cells. The cellular localization of the tracer was assessed by micro-autoradiography. Twenty-two out of 27 patients underwent 99m Tc-MIBI scan within a week of bone marrow sampling. Whole-body images were obtained 10 min after intravenous injection of 555 MBq of the tracer; the extension and intensity of 99m Tc-MIBI uptake were graded using the semiquantitative score. A statistically significant correlation was found between in vitro uptake of 99m Tc-MIBI and both plasma cell infiltration (Pearson's coefficient of correlation r=0.69, P 99m Tc-MIBI inside the plasma cells infiltrating the bone marrow. Therefore, our findings show that the degree of tracer uptake both in vitro and in vivo is related to the percentage of infiltrating plasma cells which accumulate the tracer in their inner compartments. (orig.)

  19. Asialoglycoprotein-receptor-targeted hepatocyte imaging using {sup 99m}Tc galactosylated chitosan

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun-Mi [Department of Nuclear Medicine, Research Institute of Clinical Medicine, Chonbuk National University School of Medicine, Jeonju, Jeonbuk (Korea, Republic of); Jeong, Hwan-Jeong [Department of Nuclear Medicine, Research Institute of Clinical Medicine, Chonbuk National University School of Medicine, Jeonju, Jeonbuk (Korea, Republic of)]. E-mail: jayjeong@chonbuk.ac.kr; Kim, Se-Lim [Department of Nuclear Medicine, Research Institute of Clinical Medicine, Chonbuk National University School of Medicine, Jeonju, Jeonbuk (Korea, Republic of); Sohn, Myung-Hee [Department of Nuclear Medicine, Research Institute of Clinical Medicine, Chonbuk National University School of Medicine, Jeonju, Jeonbuk (Korea, Republic of); Nah, Jae-Woon [Division of Applied Materials Engineering, Department of Polymer Science and Engineering, Sunchon National University, Sunchon, Jeonnam (Korea, Republic of); Bom, Hee-Seung [Department of Nuclear Medicine, Chonnam National University School of Medicine, Gwangju (Korea, Republic of); Park, In-Kyu [School of Agricultural Biotechnology, Seoul National University, Seoul (Korea, Republic of); Cho, Chong-Su [School of Agricultural Biotechnology, Seoul National University, Seoul (Korea, Republic of)

    2006-05-15

    This study investigated the usefulness of {sup 99m}Tc hydrazinonicotinamide-galactosylated chitosan (HGC) in hepatocyte imaging. HGC was obtained by coupling the galactose moiety of both lactobionic acid and succinimidyl 6-hydrazinonicotinate hydrochloride (succinimidyl HYNIC). The coupled product was then radiolabeled with {sup 99m}Tc using stannous chloride and tricine as reducing agent and coligand, respectively. Labeling efficiency was >90% both in room temperature and in serum up to 24 h after injection. The hepatic uptake properties of {sup 99m}Tc HGC were studied in Balb/C mice. {sup 99m}Tc HGC and {sup 99m}Tc hydrazinonicotinamide chitosan (HC) were intravenously injected into mice, with receptor binding identified by coinjection with 9 and 14 mg of free galactose. Images were acquired with a {gamma}-camera. After injection via the tail vein of the mice, {sup 99m}Tc HGC showed high selectivity for the liver, while {sup 99m}Tc HC without a galactose group showed low liver uptake. In addition, the hepatic uptake of {sup 99m}Tc HGC was blocked by coinjection of free galactose. Tissue distribution was determined at three different times (10, 60 and 120 min). The liver accumulated 13.16{+-}2.72%, 16.11{+-}5.70% and 16.55{+-}2.28% of the injected dose per gram at 10, 60 and 120 min after injection, respectively. {sup 99m}Tc HGC showed specific and rapid targeting of hepatocytes. It is a promising receptor-specific radiopharmaceutical with potential applications in liver imaging for the evaluation of hepatocytic function.

  20. Evaluation of breast MIBI-Tc 99 m scintigraphy for the detection of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Loriaux, C.; Baeyens, L.; Paternot, J.; Martin, P.; Verhas, M. [Hospital Universitaire Brugmann, Bruxelles (Belgium). Service de Medecine Nucleaire et Clinique de Senologie

    1997-12-31

    Full text. The aim of the work was to appreciate the contribution of MIBI-Tc 99 m scintigraphy for the detection of breast cancer and to situate this procedure in comparison with mammography 5 (X-ray M) and echography (E C). 21 patients presenting suspected lesion on clinical evaluation/or mammography were referred to the department for breast MIBI-Tc 99 m scintigraphy. 10 min after IV injection of MIBI-Tc 99 m 3 planar scan were realized with a present time of 10 min. The whole investigation including X-ray and surgical procedures were performed within 15 days. The pathologic findings were: 21 malignant lesion (18 canal cancers, 3 lobular cancers), 4 benign lesions (1 fibroadenoma, 2 granuloma, 1 fibrocystic disease). Lesions were bilateral in 3 cases and there was 1 bifocal lesion. 17 tumours were palpable and 8 not palpable, 10 lesion were <1 cm (40%), 9 were between 1,1 and 2,5 cm (36%) and 7 were >2,5 cm (24%). The overall sensitivity and specificity for MIBI-Tc 99 m were 67% and 75% respectively. For the group of palpable tumours, sensitivity of MIBI-Tc 99 m was 86%. In three cases, the X-ray M was difficult to interpret, the MIBI-Tc 99 m was true positive. In 3 false positive X-ray M procedures, the scintigraphy was true negative but, whatever the size of the tumor the best sensitivity was obtained with X-ray M (71%) and E C (70%) while for MIBI Tc-99 m, sensitivity was less (67%). MIBI-Tc 99 m appears to be a complementary tool in cases of difficulty of interpretation of mammography particularly in case of recurrence of the disease

  1. A comparative study of 99Tcm-tetrofosmin and 99Tcm-MIBI myocardial imaging

    International Nuclear Information System (INIS)

    Zhao Kui; Chen Peng; Zhang Furong; Shen Wenhua

    2001-01-01

    Objective: To evaluate the value of 99 Tc m -tetrofosmin myocardial imaging for detecting coronary artery disease. Methods: Twenty-seven patients underwent 99 Tc m -tetrofosmin SPECT, twenty-six patients underwent 99 Tc m -MIBI SPECT; coronary angiography was performed on patients included in both groups (≥50% luminal diameter stenosis was considered significant coronary stenosis). Results: 99 Tc m -tetrofosmin produced high quality myocardial images from 30 min to several hours postinjection, the outlines of myocardial perfusion images provided by 99 Tc m -tetrofosmin imaging were clearly discernible. One-day exercise/rest 99 Tc m -tetrofosmin myocardial perfusion imaging was feasible and had a high sensitivity for detection of coronary artery disease. Sensitivities of 99 Tc m -tetrofosmin SPECT and 99 Tc m -MIBI SPECT for detecting coronary artery disease were 90% and 94%, respectively. The 95% confidence limits of both sensitivities were 68.65% - 98.77% and 72.33% - 99.86%, respectively; the positive predictive values of both imaging agents were 90.0% and 89.5%, respectively, the 95% confidence limits of those were 68.38% - 98.77% and 72.33% - 99.86% respectively; the positive predictive values of both imaging agents were 90.0% and 89.5%, respectively, the 95% confidence limits of those were 68.38% - 98.77% and 66.38% - 98.70%, respectively; efficiencies of both imaging agents were 85.2% and 88.5%, respectively. The 95% confidence limits of both efficiencies were 65.81% - 95.78% and 69.44 - 98.70%, respectively. The specificity for both imaging agents was 71% and 75%. There was no significant difference among above results (P > 0.05). No ECG abnormalities were found following the injection of 99 Tc m -tetrofosmin SPECT. There were no drug-related effects on blood pressure, heart rate and body temperature. This experiment failed to provide the negative predictive value of the myocardial perfusion imaging with 99 Tc m -tetrofosmin because that few patients with

  2. MIBI Tc-99m uptake due to breast cancer recurrence as an incidental finding in a patient with atypical chest pain

    International Nuclear Information System (INIS)

    Saavedra, P.; Cano, R.; Morales, R.; Urquiaga, J.; Negron, S.; Munoz, L.; Aguilar, C.; Mendoza, G.; Lopez, D.; Carlos, I.

    2005-01-01

    The purpose of this paper is lo report incidental findings of uptake of Tc99m-MIBI in anterior chest in a patient evaluated for a typical chest pain. A retrospective data collection was performed through chart review of the patient, a 67 year-old women, who had atypical chest pain with cardiac risk factors (hypertension, obesity, hypercholesterolemia, diabetes) with history of left total mastectomy (1995) without adjuvant chemotherapy and negative follow-up. Myocardial Perfusion imaging with Tc99m-MIBI was normal and showed uptake in anterior left chest in sagital views, described as suspected recurrent breast cancer. Oncological and cardiological evaluation of the patient was done and detected minimal palpable lesion in the surgery scar. Incisional biopsy of the lump in the surgery scar was positive for Infiltrative Ductal Breast Carcinoma. Tc-99m-MIBI is useful for detection of recurrence of breast carcinoma in surgery scar

  3. Bcl-2 overexpression prevents 99mTc-MIBI uptake in breast cancer cell lines

    International Nuclear Information System (INIS)

    Aloj, Luigi; Zannetti, Antonella; Caraco, Corradina; Del Vecchio, Silvana; Salvatore, Marco

    2004-01-01

    We have previously shown a correlation between the absence of technetium-99m methoxyisobutylisonitrile ( 99m Tc-MIBI) uptake and overexpression of the anti-apoptotic protein Bcl-2 in human breast carcinoma. To establish a direct cause-effect relationship between Bcl-2 overexpression and reduced 99m Tc-MIBI uptake, MCF-7 and T47D breast cancer cell lines were stably transfected with the human Bcl-2 gene to increase intracellular protein levels and tested for 99m Tc-MIBI uptake. All clones overexpressing Bcl-2 showed a dramatic reduction of 99m Tc-MIBI uptake as compared with mock transfected control cells. Tracer uptake was promptly and partially restored by induction of apoptosis with staurosporine treatment. After 4.5 h of staurosporine treatment, a tenfold increase in 99m Tc-MIBI uptake was observed in treated as compared with untreated Bcl-2 overexpressing cells. Our findings provide a rational basis for the development of an in vivo test to detect Bcl-2 overexpression in human tumours. (orig.)

  4. [Imaging of hyperparathyroidism-Ultrasonography and 99mTc-MIBI scintigraphy-].

    Science.gov (United States)

    Kawabe, Joji; Higashiyama, Shigeaki; Yoshida, Atsushi; Kotani, Kohei; Shiomi, Susumu

    2016-06-01

    Treatments for primary hyperparathyroidism due to adenoma, hyperplasia and carcinoma and secondary hyperparathyroidism are mainly surgical resections of them. Accurate imaging diagnoses of the existences and the regions are very important for reductions of invasiveness. We describe ultrasonography and (99m)Tc-MIBI scintigraphy of hyperparathyroidism. We explain an advantage, a disadvantage and diagnosability of these modalities. We mention utilities of SPECT/CT, too. We show echogram and (99m)Tc-MIBI scintigraphy images about 3 cases of hyperparathyroidism.

  5. Non-visualized Thyroid Gland by Tc-{sup 99m} MIBI Scan with Normal Thyroid Scan

    Energy Technology Data Exchange (ETDEWEB)

    Koca, Gokhan; Atilgan, Hasan Ikbal; Baskin, Aylin; Demirel, Koray; Korkmaz, Meliha [Ankara Training and Research Hospital, Ankara (Turkmenistan)

    2013-09-15

    We present the case of a 21-year-old man who was referred to us for parathyroid scintigraphy with high blood levels of intact parathormone and osteoporosis. Several methods and radiopharmaceuticals, e.g., Tc-99m MIBI and Tl-201 chloride/Tc-99m pertechnetate (Tl-201/TcPO{sup -4}) subtraction, are commonly used for this purpose. We present the case of a thyroid gland that demonstrates quite normal Tc-99m pertechnetate uptake, no accumulation of Tc-99m MIBI, and very low grade Tl-201 uptake. To the best of our knowledge, no similar case has been reported previously. A 21-year-old male with osteoporosis and growth-development retardation was referred for MIBI parathyroid scan because of high blood levels of intact parathormone and bone-specific alkaline-phosphatase, which were 219.4 (15-88 pg/ml) and 355 (21-58 U/L), respectively. In his Tc-99m pertechnetate (TcPO{sup -4}) pinhole scintigraphy, bilateral clearly visualized radioactivity accumulation in the thyroid gland was seen. In both early or late images of the Tc-99m MIBI parathyroid scan, the thyroid gland was not visualized. Therefore, a Tl-201/TcPO{sub -4} subtraction scan method was used. However, the Tl-201 accumulation level in the thyroid gland was not sufficient for the subtraction method. In his thyroid ultrasonography, the thyroid gland echo was homogenous, and there was neither any solid nor cystic lesion. The physical examination of his neck was normal. Other laboratory findings were all normal as follows. TSH: 3.03 (0.35-5.6 IU/mL), free T3: 3.66 (2.5-3.9 pg/mL), free T4: 0.90 (0.59-1.3 ng/dL), Anti-TPO:0.3 (0.40 IU/mL), Anti-TG-Ab: <2.2 (0-+u/L), TSH receptor Ab: 1.0 (0.14 U/L), osteocalcine: 9.13 (1.5-15 ng/dL), growth hormone: 1.3 (0.014-5.21), calcitonin:17 (0.150 ng/mL), sedimentation:6 (0.15 mm/h). There were no significant symptoms of acute or chronic thyroiditis. The cause for discordant uptake in the thyroid gland with T1-201 and Tc-99m MIBI scan could not be provided through clinical or

  6. Additional diagnostic value of 99Tcm-MIBI imaging over 'cold' nodules in 99Tcm thyroid imaging proved by ROC analysis

    International Nuclear Information System (INIS)

    Mei Ping; Qin Yongde; Wang Saigang; Ruxianguli; Baya; Lv Jie; Xie Bing; Sun Xiaoyan

    2007-01-01

    Objective: More studies have found that 99 Tc m -MIBI thyroid imaging may provide more differential diagnostic value than traditional 99 Tc m O 4 - thyroid imaging. This study attempted to analyze the receiver operating characteristic (ROC) curves to verify the additional diagnostic value of 99 Tc m -MIBI over 99 Tc m O 4 - thyroid imaging in the differentiation of the 'cold' nodules. Methods: Sixty-eight patients initially diagnosed with 'cold' nodules in 99 Tc m O 4 - thyroid scintigraphy were selected for further 99 Tc m -MIBI thyroid imaging at early (15 min after 99 Tc m -MIBI intravenous injection, ER) and delayed phase (2 h after injection, DR). Semi-quantitative analysis was performed using tumor/normal tissue (T/N) ratio both at ER and DR, with 0.8 defined as the threshold for differential diagnoses. In ROC curves analyses, the ratios from tumor/submaxillary gland (T/S) and tumor/heart (T/H) were derived to obtain the most proper differential diagnostic thresholds. Results: Of all patients with the 'cold' nodules, only eight cases were finally diagnosed on pathology with thyroid malignancy, while other 60 were benign. For differential diagnoses, the sensitivity, specificity and accuracy of semi-quantitative 99 Tc m -MIBI thyroid imaging were 100.0%, 76.7% and 79.4% respectively. However, with thresholds of T/N=0.995, T/S=0.995, T/H=1.005 derived from ROC curves for DR 99 Tc m -MIBI imaging, the differential diagnostic sensitivities were 100.0%, 87.5%, 75.0% and the specificities were 90.0%, 85.0%, 83.3% respectively. The areas under the ROC curves were 0.949, 0.876 and 0. 867 respectively for DR, all significantly larger than those of ER. Statistical difference was also evident between threshold values of 0.8 and 0.995 (χ 2 =6.125, P 99 Tc m -MIBI thyroid imaging provide additional diagnostic value over 99 Tc m O 4 - thyroid imaging for the differentiation of the 'cold' nodules. For 99 Tc m -MIBI thyroid imaging, DR is more valuable than ER in the ROC

  7. Comparison of uptake of 99mTc-MIBI, 99mTc-tetrofosmin and 99mT-Q12 into human breast cancer cell lines

    International Nuclear Information System (INIS)

    Yong, M. de; Bernard, B.F.; Breeman, W.A.P.; Ensing, G.; Benjamins, H.; Bakker, W.H.; Visser, T.J.; Krenning, E.P.

    1996-01-01

    Technetium-99m hexakis-2-methoxyisobutyl-isonitrile (MIBI), 99m Tc-tetrofosmin and 99m Tc-Q12 were all introduced for myocardial imaging but found additional applications as they are taken up by different tumours, enabling imaging of these lesions in patients. The aim of this study was to compare the uptake characteristics of these compounds in vitro in the human adenocarcinoma breast cell lines MCF-7 and ZR-75. It was shown that 99m Tc-MIBI had the highest cellular uptake (15.9%±0.5% dose/mg protein after 60 min in MCF-7, and 14.2%±0.4% dose/mg protein in ZR-75), followed by 99m Tc-tetrofosmin (6.8%±0.6% dose/mg protein in MCF-7, and 8.2%±0.2% dose/mg protein in ZR-75) and 99m TC-Q12 (3.2%±0.1% dose/mg protein in MCF-7, and 3.5%±0.3% dose/mg protein in ZR-75 cells). For all three compounds tenfold differences in specific activity did not influence total cell-associated radioactivity. Uptake of 99m Tc-MIBI and 99m Tc-tetrofosmin was obviously lower at 4 C than at 37 C, whereas 99m Tc-Q12 uptake showed only slight temperature dependence. When uptake was compared in cells grown to different cell densities (1 mg/ml cellular protein versus 0.3 mg/ml), no differences in uptake were detected when uptake was corrected for the amount of cellular protein present in the dishes. Furthermore, for all compounds it was shown that cellular radioactivity decreased rapidly after washing. Apart from the differences in cellular uptake of the three compounds after 60 min, no differences in residual cellular radioactivity after washing were found between the different compounds when expressed as a percentage of their 60-min uptake, suggesting that the efflux process of the radiolabelled compounds was similar. The differences in cell-associated activity after 60 min were thus presumably caused by differences in uptake. (orig./MG)

  8. Studies of techniques for the post-elution concentration of 99mTc obtained from gel type 99Mo/99mTc generators

    International Nuclear Information System (INIS)

    Suzuki, Katia Noriko

    2009-01-01

    On average 80% of the radiopharmaceuticals used in Nuclear Medicine are labeled with 99 mTc due to its physical properties and easy attainment through of 99 Mo/ 99 mTc generators. The Directory of Radiopharmacy (DIRF) of IPEN-CNEN/SP developed a gel type chromatographic generator of MoZr with 99 Mo produced by 98 Mo(n,γ) 99 Mo reaction that occurs at the IEA-R1 Nuclear Reactor. The gel is composed of zirconium molybdate with elution volume of 12 mL with an activity of 11100 MBq (300 mCi) producing a radioactive concentration of 925 MBq (25 mCi)/mL. The fission generator gives a higher radioactive concentration around 1850 MBq (50 mCi)/mL. The aim of this work is to study a system of post-elution concentration of 99 mTc for the attainment of a high enough radioactive concentration to meet the demands of the market, with a proved quality. Two types of systems of post-elution concentration were developed: the single and the tandem. The most appropriate system for the gel generator of 99 Mo/ 99 mTc, being at the same time sterile and vacuum automated, was the tandem system using Dionex 2.5 cc/QMA cartridges. The gel generator is eluted with 10 mL of solution of 0.1% NaCl and the pertechnetate anion is retained in the QMA cartridge and further eluted with 4 mL of saline. The process takes no more than 30 minutes. The elution efficiency of the system of concentration was 90 %. At the beginning of 2009 a global crisis in the supply of 99 Mo took place making it necessary the development of alternative technologies for the production of 99 Mo/ 99 mTc generators using fission produced 99 Mo and the development of an appropriate method to extend the useful life of this generator. The results of this study showed that the same system developed for the post- concentration of the gel generator can be employed for the fission generator, using the tandem system, giving a concentration factor of 3 for the elution of 99 mTc. (author)

  9. The Use of Sodium Hypochlorite Solution for (n,γ99Mo/99mTc Generator Based on Zirconium-Based Material (ZBM

    Directory of Open Access Journals (Sweden)

    I. Saptiama

    2015-08-01

    Full Text Available The many problems in preparing fission product 99Mo led into this work to develop 99Mo/99mTc generator using neutron-irradiated natural MoO3 targets and, more specifically, to develop a zirconium-based material (ZBM for chromatography columns that have an adsorption capacity of more than 100 mg Mo/g ZBM. This paper reports our recent experiments in the use of sodium hypochlorite solution of various concentrations to improve the yield of 99mTc in performance of (n,γ99Mo/99mTc generators based on the ZBM. The synthesized ZBM was coated with tetraethyl orthosilicate for improving the hardness of the material. The adsorption of [99Mo]molybdate into ZBM was carried out by reacting ZBM into [99Mo]molybdate solution at 90°C to form ZBM-[99Mo] molybdate. ZBM-[99Mo]molybdate was then packed into generator column, then eluted with 10 × 1 mL of saline followed by 1 × 5 mL of NaOCl solution. The NaOCl solution concentrations used were 0.5%; 1%; 3%; and 5% for each column, respectively. This study resulted in a ZBM which has a 99Mo adsorption capacity of 167.5 ± 3.4 mgMo/g ZBM, as well as in a yield eluate of 99mTc of up to 70%, and the find that the optimum NaOCl concentration was 3%. The use of sodium hypochlorite solution affected 99Mo breakthrough. The higher sodium hypochlorite concentration used, the more 99Mo breaktrough exist on 99mTc eluate.

  10. 99mTc-MIBI, 99mTc-tetrofosmin and 99mTc-Q12 in vitro and in vivo

    International Nuclear Information System (INIS)

    Bernard, Bert F.; Krenning, Eric P.; Breeman, Wout A. P.; Ensing, Geert; Benjamins, Harry; Bakker, Willem H.; Visser, Theo J.; Jong, Marion de

    1998-01-01

    The aim of this study was to compare uptake of 99m Tc-MIBI, 99m Tc-tetrofosmin and 99m Tc-Q12 in vitro and biodistribution in vivo in rats. In vitro, uptake decreased in the order MIBI→tetrofosmin→Q12. Uptake of MIBI and tetrofosmin, but not of Q12, in cultured tumor cells was dependent on the plasma membrane and mitochondrial potential. In vivo, heart uptake of all three compounds was high and stable. Tumor uptake decreased in the order MIBI→Q12→tetrofosmin and the tumor/blood ratio in the order MIBI→tetrofosmin→Q12

  11. Inhibition of early 99mTc-MIBI uptake by Bcl-2 anti-apoptotic protein overexpression in untreated breast carcinoma

    International Nuclear Information System (INIS)

    Del Vecchio, Silvana; Zannetti, Antonella; Aloj, Luigi; Caraco, Corradina; Ciarmiello, Andrea; Salvatore, Marco

    2003-01-01

    Lack of technetium-99m methoxyisobutylisonitrile ( 99m Tc-MIBI) uptake is consistently reported to predict poor response to subsequent chemotherapy in a variety of human malignant tumours. Since 99m Tc-MIBI accumulates within mitochondria, which also play a central role in apoptosis through the integration of death signals by Bcl-2 family members, we tested whether early 99m Tc-MIBI uptake is affected by alterations of the apoptotic pathway. Forty-two breast cancer patients were intravenously injected with 740 MBq of 99m Tc-MIBI and planar images were obtained 10 min post injection with the patients in the prone lateral position. Ten carcinomas failed to accumulate 99m Tc-MIBI and could not be visualised on scintigraphic images despite being larger than 1.8 cm (MIBI negative). Thirty-two of the 42 breast carcinomas showed focal uptake of 99m Tc-MIBI (MIBI positive), and 10 min tumour-to-background ratios (T/B) varied between 1.14 and 6.93. The apoptotic index, the rate of proliferation, and the expression of the anti-apoptotic Bcl-2 protein and pro-apoptotic Bax protein were assessed in surgically excised tumours. All MIBI-negative carcinomas showed a dramatic and statistically significant reduction in the apoptotic index as compared with MIBI-positive lesions (mean±SD, 0.14±0.15 vs 1.28±0.83, P 99m Tc-MIBI in breast carcinomas is affected by alterations of apoptotic pathway. High levels of Bcl-2, despite the stabilisation of mitochondrial membrane potentials, prevent accumulation of 99m Tc-MIBI in tumour cells. In conclusion, absent or reduced early 99m Tc-MIBI uptake in large tumours may indicate a Bcl-2-mediated resistance to chemo- and radiotherapy. (orig.)

  12. Three-dimensional display of 99mTc-MIBI myocardial scintigraphy

    International Nuclear Information System (INIS)

    Kashimada, Akio; Machida, Kikuo; Honda, Norinari

    1992-01-01

    One of 99m Tc-hexakis, 99m Tc-methoxyisobutyl isonitrile (MIBI), has been demonstrated to have a myocardial uptake proportional to regional coronary blood flow. In this study, 99m Tc-MIBI myocardial scintigraphy was performed for 16 patients with ischemic heart disease. After injection of 740 MBq of 99m Tc-MIBI, 64 projection images were collected during a 360-degree rotation. Three-dimensional (3D) display of the left ventricle was reconstructed with depth-shading method from 99m Tc-MIBI SPECT images, which were reconstructed by filtered back projection method. In 9 of the patients, left ventricular cineangiography were performed as diagnostic gold standard. Four physicians blinded to patients' clinical information interpreted 3D images and SPECT images on separate occasions. Diagnosis of hypoperfusion by 3D displays agreed with those of SPECT in 92.9% (104/112 segments), and disagreed in 7.1% (8 segments). Sensitivity and specificity of 3D images were 87.0% and 93.9%, which were not statistically different (p<0.05) from that of SPECT images (91.3%, 97.0%). Receiver operating characteristic (ROC) analysis revealed nearly identical curves for the two. Although 3D display had nearly identical diagnostic ability with SPECT, observers reported that 3D images were easier to diagnose than SPECT images. An advantage of the 3D display is that the display gives a more realistic impression of the left ventricle to an observer than tomography or planar imaging. Another advantage is that 3D display can reduce the amount of data storage compared with that of SPECT. In conclusion, 3D images may be useful for diagnosis of hypoperfusion of left ventricle. (author)

  13. Prognostic value of stress 99Tcm-MIBI myocardial perfusion SPECT after acute myocardial infarction

    International Nuclear Information System (INIS)

    Sui Xutao; Chen Zhi; Gao Shenghai; Shen Li; Li Shang'ai

    2003-01-01

    Objective: To investigate relativity of acute myocardial infarction (AMI) with clinical, stress test and perfusion imaging parameters and to assess predictive value on hard events of cardiac death or recurrent nonfatal AMI. Methods: One hundred and one patients of AMI underwent stress 99 Tc m -MIBI SPECT before discharge. Hard and soft events were followed-up, relative factors with cardiac events were analyzed by statistical methods and predictive value on hard events were assessed. Results: Independent predictors by multivariate analysis for cardiac hard events or all cardiac events consisted of a history of prior AMI (RR=5.30, CI 2.17-12.98), a low exercise capacity (RR=6.28, CI 1.92-21.46) and left ventricular ejection fraction 99 Tc m -MIBI SPECT is a single test that can provide exercise parameter, cardiac perfusion imaging information and left ventricular function assessment to identify high-risk and estimate hard prognosis at discharge of AMI patients. These high-risk patients can be referred for early invasive evaluation and intervention

  14. Diagnosis the metastatic sentinel node with Tc-99m-MIBI

    International Nuclear Information System (INIS)

    Georgiev-Predic, M.; Predic, P.; Karner, I.; Dodig, D.

    2002-01-01

    Aim: The purpose of this study was to analyse the occurrence of visualisation malignancy of sentinel node during preoperative lymphoscintigraphy in breast cancer. To precisely diagnose the metastatic sentinel node is very difficult. Material and Methods:Preoperative lymphoscintigraphy was performed in 47 patients with breast cancer after injection of Tc-99m-MIBI. We injected 20-40 MBq Tc-99m-MIBI peritumoral. Anterior and prone lateral planar images were obtained 2h, 4h, 6h and 20h after injection. The uptake were in region of sentinel node calculed. The sentinel node was intraoperatively identified and histologically analysed. Results: In 27 patients with intraoperatively detected metastatic sentinel node was in 25 patients increased uptake in sentinel node on scintigrams after 20h detected. In 20 patients with intraoperatively non detected metastatic sentinel node was in 19 patients increased uptake on scintigrams ower 2h-6h detected. Conclusion: The results indicated that is lymphoscintigraphy with Tc-99m-MIBI is a new method for detection the preoperatively metastatic sentinel node

  15. Determination of radiochemical yield of {sup 99m}Tc radiopharmaceutical preparations using gamma counter and linear radiochromatography scanner

    Energy Technology Data Exchange (ETDEWEB)

    Martins, Patricia de A.; Moura, Rebeca G.; Shiki, Andressa M.; Fukumori, Neuza T.O.; Matsuda, Margareth M.N., E-mail: patyosborne@yahoo.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    The radiochemical purity (RCP) evaluation is a prerequisite for radiopharmaceuticals before the administration in patients. RCP is defined as the proportion of the total radioactivity in the product that is present in the specified chemical form. The most widely used techniques for RCP determination in radiopharmaceutical preparations are thin layer chromatography (TLC-Al), instant thin layer chromatography (ITLC-SG) and paper chromatography (PC). These techniques combined with radioactivity detection are one of the most important tools in the RCP of the radiopharmaceutical compounds. Several methods are used for the determination of the spatial distribution of radioactivity on the strips. The aim of this study was to compare two methods for radioactivity measurement in the determination of RCP in {sup 99m}Tc radiopharmaceuticals using gamma counter and linear radiochromatography scanner. Lyophilized radiopharmaceuticals were labeled with {sup 99m}Tc. The analysis was carried out using TLC-Al and high performance thin layer chromatography (HPTLC-Cellulose) sheets, ITLC-SG and 3MM Whatman PC. The radioactivity distribution was determined by counting each strip during 1 minute in a radiochromatography TLC scanner. For comparison, the strips were cut into small pieces and each one was separately measured in a gamma-counter during 0.20 minutes in 70-210 KeV {sup 99m}Tc window. USP 36 and FDA specify that not less than 90% of the total radioactivity must be in the spot corresponding to {sup 99m}Tc labeled compound. In conclusion, the procedure for RCP determination of ALBUMINA-TEC, DEX500-TEC, ECD-TEC, MACRO-TEC and MIBI-TEC can be faster using radiochromatography. (author)

  16. Separation of sup(99m)Tc from 99MoO3

    International Nuclear Information System (INIS)

    Tomicic, M.

    1977-07-01

    At the present time sup(99m)Tc is widely used in nuclear medicine and its uses are increasing. It can be produced by various methods, and of those most frequently used today two have special features making them particularly applicable to the large-scale production of instant sup(99m)Tc - these are solvent extraction with methyl-ethyl-ketone and the sublimation methods. This report presents a bibliographic review of these methods, their main perfomance parameters, and experience obtained from the development and operation of a sublimation generator. Separation of sup(99m)Tc from irradiated MoO 3 was carried out with high yields (75-95%) after multiple repetition of the separation process with molybdenum trioxide heated for half an hour at a maximum temperature of 850-890 deg C in an air flow. The activity ratio of molybdenum in the separated sup(99m)Tc was of the order of 4 x 10 -5 . (author)

  17. Hypoxia-induced redox alterations and their correlation with {sup 99m}Tc-MIBI and {sup 99m}Tc-HL-91 uptake in colon cancer cells

    Energy Technology Data Exchange (ETDEWEB)

    Abrantes, Ana Margarida [Biophysics/Biomathematics Institute, IBILI, Faculty of Medicine, University of Coimbra, 3000-548 Coimbra (Portugal); Centre of Investigation on Environment Genetics and Oncobiology (CIMAGO), Faculty of Medicine, University of Coimbra, 3000-548 Coimbra (Portugal)], E-mail: mabrantes@ibili.uc.pt; Silva Serra, Maria Elisa [Chemistry Department, Faculty of Sciences and Technology, University of Coimbra, 3000-535 Coimbra (Portugal); Goncalves, Ana Cristina [Biochemistry Institute, Faculty of Medicine, University of Coimbra, 3000-548 Coimbra (Portugal); Centre of Investigation on Environment Genetics and Oncobiology (CIMAGO), Faculty of Medicine, University of Coimbra, 3000-548 Coimbra (Portugal); Rio, Joana; Oliveiros, Barbara; Laranjo, Mafalda [Biophysics/Biomathematics Institute, IBILI, Faculty of Medicine, University of Coimbra, 3000-548 Coimbra (Portugal); Rocha-Gonsalves, Antonio Manuel [Chemistry Department, Faculty of Sciences and Technology, University of Coimbra, 3000-535 Coimbra (Portugal); Centre of Investigation on Environment Genetics and Oncobiology (CIMAGO), Faculty of Medicine, University of Coimbra, 3000-548 Coimbra (Portugal); Sarmento-Ribeiro, Ana Bela [Biochemistry Institute, Faculty of Medicine, University of Coimbra, 3000-548 Coimbra (Portugal); Centre of Investigation on Environment Genetics and Oncobiology (CIMAGO), Faculty of Medicine, University of Coimbra, 3000-548 Coimbra (Portugal); Filomena Botelho, Maria [Biophysics/Biomathematics Institute, IBILI, Faculty of Medicine, University of Coimbra, 3000-548 Coimbra (Portugal); Centre of Investigation on Environment Genetics and Oncobiology (CIMAGO), Faculty of Medicine, University of Coimbra, 3000-548 Coimbra (Portugal)

    2010-02-15

    Colorectal cancer is one of the most common malignancies in the Western world and is an example of a solid tumour in which hypoxia is a common feature and develops because of the inability of the vascular system to supply adequate amounts of oxygen to growing tumours. Hypoxia effects on tumour cell biology can be detected and characterized using different methods. The use of imaging with {gamma}-emitting radionuclides to detect hypoxic tissue was first suggested by Chapman in 1979 [N Engl J Med 301 (1979) 1429-1432]. {sup 99m}Tc-4,9-diaza-3,3,10,10-tetramethyldodecan-2,11-dione dioxime, also known as {sup 99m}Tc-HL-91, has been among the most studied hypoxia markers. The objective of this study was to correlate the uptake of {sup 99m}Tc-HL-91 and {sup 99m}Tc-MIBI in colon cancer cells under normoxic and hypoxic conditions and to compare this information with some parameters such as oxidative stress and mitochondrial dysfunction of the cells analyzed by flow cytometry. Our results show that the in vitro {sup 99m}Tc-HL-91 uptake is higher in hypoxic conditions, which is confirmed by the decreased uptake of {sup 99m}Tc-MIBI. Flow cytometry results demonstrate that hypoxic conditions used are not enough to induce cellular death, but are responsible for the alterations in the intracellular redox environment, namely, increase of ROS production, proteic pimonidazol-derived adduct formation and alteration in the mitochondrial membrane permeability. Therefore, these results confirm that {sup 99m}Tc-HL-91 is a radiopharmaceutical with favourable characteristics for detecting hypoxia.

  18. Left ventricular function assessment using 123I/99mTc dual-isotope acquisition with two semi-conductor cadmium–zinc–telluride (CZT cameras: a gated cardiac phantom study

    Directory of Open Access Journals (Sweden)

    Tanguy Blaire

    2016-11-01

    Full Text Available Abstract Background The impact of increased energy resolution of cadmium–zinc–telluride (CZT cameras on the assessment of left ventricular function under dual-isotope conditions (99mTc and 123I remains unknown. The Amsterdam-gated dynamic cardiac phantom (AGATE, Vanderwilt techniques, Boxtel, The Netherlands was successively filled with a solution of 123I alone, 99mTc alone, and a mixture of 123I and 99mTc. A total of 12 datasets was acquired with each commercially available CZT camera (DNM 530c, GE Healthcare and DSPECT, Biosensors International using both energy windows (99mTc or 123I with ejection fraction set to 33, 45, and 60 %. End-diastolic (EDV and end-systolic (ESV volumes, ejection fraction (LVEF, and regional wall motion and thickening (17-segment model were assessed using Cedars-Sinai QGS Software. Concordance between single- and dual-isotope acquisitions was tested using Lin’s concordance correlation coefficient (CCC and Bland–Altman plots. Results There was no significant difference between single- or simultaneous dual-isotope acquisition (123I and 99mTc for EDV, ESV, LVEF, or segmental wall motion and thickening. Myocardial volumes using single- (123I, 99mTc and dual-isotope (reconstructed using both 123I and 99mTc energy windows acquisitions were, respectively, the following: EDV (mL 88 ± 27 vs. 89 ± 27 vs. 92 ± 29 vs. 90 ± 26 for DNM 530c (p = NS and 82 ± 20 vs. 83 ± 22 vs. 79 ± 19 vs. 77 ± 20 for DSPECT (p = NS; ESV (mL 40 ± 1 vs. 41 ± 2 vs. 41 ± 2 vs. 42 ± 1 for DNM 530c (p = NS and 37 ± 5 vs. 37 ± 1 vs. 35 ± 3 vs. 34 ± 2 for DSPECT (p = NS; LVEF (% 52 ± 14 vs. 51 ± 13 vs. 53 ± 13 vs. 51 ± 13 for DNM 530c (p = NS and 52 ± 16 vs. 54 ± 13 vs. 54 ± 14 vs. 54 ± 13 for DSPECT (p = NS; regional motion (mm 6.72 ± 2.82 vs. 6.58 ± 2.52 vs. 6.86 ± 2.99 vs. 6.59 ± 2

  19. Comparative study of uptake and washout of 99mTcN(NOEt)2 with 99mTc-MIBI in human cervical carcinoma cell lines

    International Nuclear Information System (INIS)

    Xing Shi'an; Zhang Yongxue; An Rui

    2002-01-01

    Objective: to investigate the cellular kinetics of bis (N-ethoxy-N-ethyl dithiocarbamato) nitrido 99m Tc(V) [ 99m TcN (NOEt) 2 ] in human cervical carcinoma cell line Hela and to compare it with that of 99m Tc hexakis-2- methoxyisobutyl isonitrile ( 99m Tc-MIBI), and hence to define the possible clinical value of 99m TcN(NOEt) 2 in tumor imaging. Methods: Using radionuclide tracer technique, 99m TcN(NOEt) 2 and 99m Tc-MIBI were incubated with human cervical carcinoma cell lines Hela at 37 degree C and at 22 degree C respectively. At several incubation times, the uptake and washout characteristics of the radiotracers in human cervical carcinoma cell line Hela were investigated and compared. Results: The maximum uptake of 99m TcN(NOEt) 2 in Hela was 46.15% and that of 99m Tc-MIBI was 12.6% (P 99m TcN(NOEt) 2 after 5 min incubation in human cervical carcinoma cell line Hela was 65% of the total uptake, while that of 99m Tc-MIBI was 50% of the total uptake (P 99m TcN(NOEt) 2 was retained in the Hela cells at one hour while 56.67% of 99m Tc-MIBI was retained (P 99m Tc-MIBI, the cellular kinetics of 99m TcN(NOEt) 2 was not temperature-dependent (the cellular kinetics is similar at 37 degree C and at 22 degree C, P>0.05). Conclusions: In vitro data suggest that 99m TcN(NOEt) 2 may be a better tracer than 99m Tc-MIBI in tumor imaging and 99m TcN(NOEt) 2 has potential application in clinical use

  20. {sup 201}Tl, {sup 99m}Tc-MIBI, {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin: relative retention and clearance kinetics in retrogradely perfused guinea pig hearts

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, Wolfgang M.; Moka, Detlef E-mail: detlef.moka@uni-koeln.de; Brockmann, Holger A.; Schomaecker, Klaus; Schicha, Harald

    2002-02-01

    Myocellular kinetics of {sup 201}Tl, {sup 99m}Tc-MIBI, {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin were investigated using retrogradely-perfused guinea-pig hearts. Relative retention decreased in the order {sup 99m}Tc-MIBI {yields}{yields} implies {sup 99m}Tc-tetrofosmin {yields}{yields} implies {sup 99m}Tc-furifosmin. {sup 201}Tl and {sup 99m}Tc-MIBI exhibited bi- (t1,t2), {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin triexponential (t1,t2,t3) time-activity-curves. Latest-phase elimination-half-life increased from {sup 201}Tl (t2) {yields}{yields} implies {sup 99m}Tc-MIBI (t2) {yields}{yields} implies {sup 99m}Tc-tetrofosmin (t3) {yields}{yields} implies {sup 99m}Tc-furifosmin (t3), showing a significant increase in deteriorating myocardium for all tracers but {sup 99m}Tc-furifosmin. Delayed elimination in deteriorating myocardium explains at least partly the redistribution phenomenon of {sup 201}Tl, and suggests a similar phenomenon for {sup 99m}Tc-MIBI and {sup 99m}Tc-tetrofosmin.

  1. Uptake of encapsulated 99mTc-MIBI into simple or pegylated liposomes in cultured cells and in tumour-bearing nude mice

    International Nuclear Information System (INIS)

    Vergote, J.; Belhaj-Tayeb, H.; Banisadr, G.; Leger, G.; Briane, D.; Moretti, J.L.

    2001-01-01

    Encapsulating 99m Tc-MIBI into liposomes could prolong its circulation half-life in blood without alteration of tracer abilities. In addition, surface coating of liposomes with polyethylene-glycol (PEG) have been shown to be efficient vehicles for antibiotics or 99m Tc-tracers. The uptake of encapsulated 99m Tc-MIBI into liposomes, simple or pegylated, in cancerous cells and its biodistribution were compared to the free 99m Tc-MIBI. The encapsulation of 99m Tc-MIBI into liposomes was obtained using a K + diffusion potential method. Untrapped 99m Tc-MIBI into liposomes preparations 'Small Unilamellar Vesicles' (SUVs) was removed by passing the SUVs through a chromatography column. 99m Tc-MIBI uptake in cells was qualified by measuring radioactivity retained in K562 and MCF7-ras cells incubated with encapsulated or free 99m Tc-MIBI. The biodistribution was explored in tumour-bearing nude mice. The efficiency with which 99m Tc-MIBI was encapsulated in liposomes was 45% - 50% for pegylated or not. In the two cell lines, the accumulation of 99m Tc-MIBI was similar either the tracer was free or encapsulated into liposomes. One hour after injection, the biodistribution showed a higher clearance for free 99m Tc-MIBI than for encapsulated tracer into liposomes. The tumour accumulated in a greater extent the encapsulated form than the free 99m Tc-MIBI. Encapsulated 99m Tc-MIBI into PEG-liposomes would be a promising radiopharmaceutical for tumour imaging in vivo. (author)

  2. Role of /sup 99/mTc pertechnetate uptake in the evaluation of thyroid function

    Energy Technology Data Exchange (ETDEWEB)

    Sucupira, M.S.; Camargo, E.E.; Nickoloff, E.L.; Alderson, P.O.; Wagner, H.N. Jr.

    1983-01-01

    To investigate the usefulness of the 20 min /sup 99/mTc-pertechnetate uptake test, the records of 246 consecutive patients were reviewed. Of these, 192 patients (151 females, 41 males; 10 weeks to 78 years) had at least one year clinical follow-up or a confirmed diagnosis by biopsy or surgery and were included in our study. In these patients, the /sup 99/mTc pertechnetate uptake and hormonal values (T3 resin uptake, T4 RIA, T-index) were obtained. These results were then compared to the clinical diagnosis at the time of the uptake and one year later. All patients received an i.v. injection of 5 mCi of /sup 99/mTc pertechnetate. Imaging was performed using a pinhole collimator and a scintillation camera interfaced to a computer. Regions of interest for the thyroid and the background were used to calculate the 20 min /sup 99/mTc pertechnetate uptake as a percentage of the injected dose. /sup 99/mTc uptake and hormonal values were confirmatory in 158 patients (82.3%): 138 were euthyroid, 18 were hyperthyroid and 2 were hypothyroid. In 29 other patients (15.1%) the pertechnetate uptake provided useful additional information and helped to identify Hashimoto's thyroiditis (8 patients); thyroid suppression by exogenous iodide, steroids or T4 (7 patients); overtreated hyperthyroidism (1 patient); persistent hyperthyroidism (5 patients); different stages of Grave's disease (4 patients); and toxic nodular goiter (4 patients). The /sup 99/mTc uptake was misleading in 5 euthyroid patients (2.6%). We have found the /sup 99/mTc pertechnetate uptake a useful adjunct to measurement of hormonal levels in patients with suspected thyroid disease.

  3. Lesion localization in patients with hyperparathyroidism using double-phase Tc-99m MIBI parathyroid scintigraphy

    International Nuclear Information System (INIS)

    Shin, Jung Woo; Ryu, Jin Sook; Kim, Jae Seung; Moon, Dae Hyuk; Hong, Seung Mo; Gong, Gyung Yub; Hong, Suk Joon; Lee, Hee Kyung

    1999-01-01

    This study was performed to evaluate the diagnostic usefulness of double-phase Tc-99m MIBI parathyroid scintigraphy with single photon emission computed tomography (SPECT) in patients with hyperparathyroidism. We also evaluated the relationship between Tc-99m MIBI uptake and oxyphil cell contents in parathyroid glands. The subjects were 28 parathyroid glands of 10 patients who underwent Tc-99m MIBI parathyroid scintigraphy and parathyroidectomy for clinically suspected hyperparathyroidism. Early and delayed pinhole images were obtained at 15 minutes and 2 hours after injection of Tc-99m MIBI, and SPECT images were followed. The weight and oxyphil cell contents of parathyroid tissue were obtained from pathologic specimen, and the scintigraphic findings were compared with histopathology. In surgical histopathology, 6 parathyroid adenomas and 9 parathyroid hyperplasias were confirmed. The sensitivity, specificity, and positive predictive value of early and delayed images were 46.7% (7/15), 76.9% (10/13), 70% (7/10) and 66.7% (10/15), 92.3% (12/13), 90.9% (10/11), respectively. SPECT image detected an additional small hyperplasia. The sensitivity, specificity, and positive predictive value of combined interpretation of early and delayed images with SPECT were 73.3% (11/15), 100% (13/13), 100% (11/11). The sensitivity was 100% (6/6) for adenoma, whereas that was 55.5% (5/9) for hyperplasia. Both adenomas and hyperplasias showed significantly increased oxyphil cell contents compared with normal parathyroid glands (p<0.0001), but the oxyphil cell content and weight were not significantly different between adenomas and hyperplasias. Double-phase Tc-99m MIBI parathyroid scintigraphy with SPECT is useful for lesion localization in patients with hyperparathyroidism. Although both adenoma and hyperplasia have increased oxyphil cell content, the sensitivity is high in adenoma, but low in hyperplasia

  4. The usefulness of 99mTc-MIBI in the detection of active pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Lee, H. J.; Jeon, D. S.; Yoo, S. D.; Lee, M. K.; Park, S. K.; Kim, S. J.; Kim, I. J.; Kim, Y. K.

    1998-01-01

    The use of radiopharmaceuticals in evaluation of pulmonary tuberculosis may help to resolve difficult diagnostic problems such as discordance between sputum examinations and chest roentgenographic findings. We investigated the usefulness of 99m Tc-methoxyisobutylisonitrile (MIBI) scintigraphy in the detection of active pulmonary tuberculosis. Forty-six patients with suspected active pulmonary tuberculosis were studied with sputum smear of AFB, sputum AFB culture, chest X-ray and MIBI scan. MIBI image was obtained 15 and 60 min after intravenous injection of 370MBq(10mCi) 99m Tc-MIBI. In 16 patients of them Ga scans were performed in addition to MIBI scan. Repeated MIBI scans were done in 7 patients with active pulmonary tuberculosis after 4∼6 months of antituberculous chemotherapy. Thirty-two patients were confirmed as active tuberculosis by sputum culture. Sensitivity of MIBI scan to active tuberculosis was 87.5%(28/32) and MIBI findings were negative in all of 14 patients with inactive disease. Focal uptake of MIBI was dense in the area that was strongly suggested active tuberculous lesions by chest roentgenogram. There was no discordance between MIBI and Ga image in 16 patients. But the uptake areas of Ga images were broader than that of MIBI images. After 4∼6 months of antituberculous treatment all repeated MIBI scans revealed negative findings except 1 patient with persistent active pulmonary tuberculosis due to drug resistance. MIBI scan could be used in the detection of active pulmonary tuberculosis as a useful noninvasive diagnostic tool

  5. To the radiotoxicity of {sup 99m}Tc radiopharmaceuticals

    Energy Technology Data Exchange (ETDEWEB)

    Ftacnikova, S [Inst. of Preventive and Clinical Medicine, 83301 Bratislava (Slovakia)

    1996-12-31

    In this paper the radiotoxicity and RBE values of Auger electrons for {sup 99m}Tc radiopharmaceuticals were discussed. Expression for the expected RBE for {sup 99m}Tc compounds is given. For the Auger electrons emitted in the decay of {sup 99m}Tc the RBE(Auger) = 10 and a value of 20 for the radiation weighing factor were recommended. (J.K.) 4 refs.

  6. Labelling, biodistribution and compartmental analysis of N-acetylcysteine labelled with Tc-99m. Comparative investigation with with {sup 99m} Tc-MIBI in an in vivo tumoral model; Estudo de marcacao, biodistribuicao e analise compartimental da N-acetil cisteina marcada com Tc-99m. Investigacao comparativa com MIBI-{sup 99m}Tc em modelo tumoral in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Faintuch, Bluma Linkowski

    1997-07-01

    Labelling and biodistribution studies were done with two different ligands, respectively Methoxy isobutyl isonitrile (MIBI) and N-acetylcysteine (NAC), employing Tc-99m as a tracer. The main objective was to assess the pharmacokinetic properties of the second substance, aiming at its possible application in cancer diagnosis. To this purpose an in vivo investigation was done using healthy and tumor-bearing rats with experimental cancer. Images of tumor-bearing rats registered in a scintillation camera indicated that with {sup 99m} Tc-MIBI none of the two selected times was adequate for visualization of the cancer mass. In contrast, {sup 99m} Tc-NAC permitted clear identification of the humor, four hours after injection. The results have demonstrated that {sup 99m} Tc-NAC is a radiopharmaceutical with affinity for cancer tissue and promising for further investigation concerning imaging diagnosis of tumors. (author)

  7. Dose calibrator linearity test: {sup 99m}Tc versus {sup 18}F radioisotopes

    Energy Technology Data Exchange (ETDEWEB)

    Willegaignon, Jose; Coura-Filho, George Barberio; Garcez, Alexandre Teles, E-mail: willegaignon@hotmail.com [Instituto do Cancer do Estado de Sao Paulo Octavio Frias de Oliveira (ICESP), Sao Paulo, SP (Brazil); Sapienza, Marcelo Tatit; Buchpiguel, Carlos Alberto [Universidade de Sao Paulo (FM/USP), Sao Paulo, SP (Brazil). Fac. de Medicina; Alves, Carlos Eduardo Gonzalez Ribeiro; Cardona, Marissa Anabel Rivera; Gutterres, Ricardo Fraga [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2015-01-15

    Objective: the present study was aimed at evaluating the viability of replacing {sup 18}F with {sup 99m}Tc in dose calibrator linearity testing. Materials and methods: the test was performed with sources of {sup 99m}Tc (62 GBq) and {sup 18}F (12 GBq) whose activities were measured up to values lower than 1 MBq. Ratios and deviations between experimental and theoretical {sup 99m}Tc and {sup 18}F sources activities were calculated and subsequently compared. Results: mean deviations between experimental and theoretical {sup 99m}Tc and {sup 18}F sources activities were 0.56 (± 1.79)% and 0.92 (± 1.19)%, respectively. The mean ratio between activities indicated by the device for the {sup 99m}Tc source as measured with the equipment precalibrated to measure {sup 99m}Tc and {sup 18}F was 3.42 (± 0.06), and for the {sup 18}F source this ratio was 3.39 (± 0.05), values considered constant over the measurement time. Conclusion: the results of the linearity test using {sup 99m}Tc were compatible with those obtained with the {sup 18}F source, indicating the viability of utilizing both radioisotopes in dose calibrator linearity testing. Such information in association with the high potential of radiation exposure and costs involved in {sup 18}F acquisition suggest {sup 99m}Tc as the element of choice to perform dose calibrator linearity tests in centers that use {sup 18}F, without any detriment to the procedure as well as to the quality of the nuclear medicine service. (author)

  8. Sup(99m)Tc compounds for diagnostic purposes

    International Nuclear Information System (INIS)

    Cifka, J.; Budsky, F.

    1980-01-01

    The applications of sup(99m)Tc in nuclear medicine are discussed, such as sodium pertechnetate in thyroid and brain scintigraphy, complex compounds in lungs and liver diao.nosis. Technetium generators are classified according to the method of separating sup(99m)Tc from 99 Mo. Adsorption generators are used, molybdate-99 is adsorbed on an Al 2 O 3 -packed column while pertechnetate-99m is eluted with 0.9% NaCl solution. Also used is continuous pertechnetate-99m extraction with methyl ethyl ketone from 0.5 M potassium molybdate and 2.5 M of potassium carbonate. The manufacture is described of kits for sup(99m)Tc radiopharmaceuticals preparation, eg., Diagos I, a gluconate complex, a lyophilisate for sup(99m)Tc-sodium pyrophosphate injections, a diagnostic kit for lung scintiscanning. (H.S.)

  9. Comparative study of gated myocardial perfusion imaging using 99Tcm-tetrofosmin and 99Tcm-sestamibi

    International Nuclear Information System (INIS)

    Wang Ruihua; Ruan Qiao; Sun Ke; Han Xingmin; Sun Bingqi; Xie Xinli; Cheng Bing; Chen Yanlin; Liu Baoping

    2013-01-01

    Objective: To compare the results of 99 Tc m -tetrofosmin (TF) and 99 Tc m -MIBI G-MPI in evaluating left ventricular myocardial perfusion and other functional parameters. Methods: TF and MIBI were both labeled by 99 Tc m and the radiochemical purities were tested. During December 2011 to May 2012, 112 patients who had examinations of CAG and echocardiograph in one week after G-MPI were divided into 99 Tc m -TF group (47 patients) and 99 Tc m -MIBI group (65 patients) by simple random sampling. Patients who suffered from severe arrhythmia, clinically suspicious of myocarditis or cardiomyopathy were excluded. The research was approved by the ethics committee, and all patients signed informed consents. One-day 99 Tc m -TF G-MPI and two-day 99 Tc m -MIBI G-MPI were performed. The left ventricular functional parameters were acquired automatically by Cedars quantitative gated SPECT (QGS) software, including LVEF, EDV, ESV, peak filling rate (PFR), peak ejection rate (PER) and phase standard difference (SD). The data were analyzed using χ 2 test, two-sample t test, paired t test and linear correlation analysis by SPSS 17.0. Results: The radiochemical purities of 99 Tc m -TF and 99 Tc m -MIBI were (97.5±0.4) % and (99.1±0.2) % respectively. The coincidence rates of 99 Tc m -TF and 99 Tc m -MIBI G-MPI with CAG were 88.9% (40/45) and 90.5% (57/63), respectively. There was no significant difference between G-MPI results of the two agents (χ 2 =0.389, P>0.05). There was also no significant difference between left ventricular functional parameters of the two agents (LVEF:(62.60±13.56)% vs (60.52±7.08)%, t=0.940; EDV: (103.3±17.29) ml vs (98.52±19.37) ml, t=1.348; ESV: (41.73±12.69) ml vs (46.05±10.81) ml, t=0.851; PER: (2.73±0.67)EDV/s vs (2.61±1.04) EDV/s, t=0.725; PFR: (2.13±0.80) EDV/s vs (2.07±1.09) EDV/s, t=0.339; phase SD: (5.58±4.16)° vs (5.97±4.64)°, t=0.450; all P>0.05). There was no significant difference between left ventricular functional

  10. Status of {sup 99}Mo-{sup 99m}Tc production development by (n, {gamma}) reaction

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, Kunihiko; Kaminaga, Masanori; Ishihara, Masahiro; Kawamura, Hiroshi [Japan Atomic Energy Agency, Oarai Research and Development Center, Oarai, Ibaraki (Japan); Mutalib, Abdul [National Nuclear Energy Agency of Indonesia (BATAN), Tangerang (Indonesia); Chakrov, Petr [Institute of Nuclear Physics, National Nuclear Center of Republic of Kazakhstan (INP-NNC-RK), Almaty (Kazakhstan)

    2012-03-15

    Technetium-99m ({sup 99m}Tc) is one of the most commonly used radioisotopes in the field of nuclear medicine. As one of effective uses of the JMTR, JAEA has a plan to produce {sup 99}Mo by (n, {gamma}) method, a parent nuclide of {sup 99m}Tc. JAEA has performed R and D on production method of {sup 99}Mo-{sup 99m}Tc in JMTR cooperating with foreign organizations and relevant Japanese enterprises under the cooperation programs. In this paper, present status of R and D for production of {sup 99}Mo-{sup 99m}Tc in JMTR under international cooperation is introduced and constructions of the irradiation and PIE facilities at the JMTR site are also described. (author)

  11. Reproducibility of an automatic quantitation of regional myocardial wall motion and systolic thickening on gated Tc-99m-MIBI myocardial SPECT

    International Nuclear Information System (INIS)

    Paeng, Jin Chul; Lee, Dong Soo; Cheon, Gi Jeong; Kim, Yu Kyeong; Chung, June Key; Lee, Myung Chul

    2000-01-01

    The aim of this study is to investigate the reproducibility of the quantitative assessment of segmental wall motion and systolic thickening provided by an automatic quantitation algorithm. Tc-99m-MIBI gated myocardial SPECT with dipyridamole stress was performed in 31 patients with known or suspected coronary artery disease (4 with single, 6 with two, 11 with triple vessel disease; ejection fraction 51±14%) twice consecutively in the same position. Myocardium was divided into 20 segments. Segmental wall motion and systolic thickening were calculated and expressed in mm and % increase respectively, using AutoQUANT TM software. The reproducibility of this quantitative measurement of wall motion and thickening was tested. Correlations between repeated measurements on consecutive gated SPECT were excellent for wall motion (r=0.95) and systolic thickening (r=0.88). On Bland-Altman analysis, two standard deviation was 2 mm for repeated measurement of segmental wall motion, and 20% for that of systolic thickening. The weighted kappa values of repeated measurements were 0.807 for wall motion and 0.708 for systolic thickening. Sex, perfusion, or segmental location had no influence on reproducibility. Segmental wall motion and systolic thickening quantified using AutoQUANT TM software on gated myocardial SPECT offers good reproducibility and is significantly different when the change is more than 2 mm for wall motion and more than 20% for systolic thickening

  12. Experimental study of 99Tcm-HL91 and 99Tcm-MIBI in mice bearing Lewis lung cancer

    International Nuclear Information System (INIS)

    Han Chunqi; Li Yaming; Ren Yangang; Yi Lijie

    2000-01-01

    Objective: To evaluate the ability of detecting lung cancer by 99 Tc m -HL91 and 99 Tc m -MIBI in mice bearing Lewis lung cancer. Methods: Four model mice underwent whole body planar imaging at 2 h, 4 h after injection of 99 Tc m -MIBI; four mice underwent whole body planar imaging at 2 h and 4 h after injection of 99 Tc m -HL91, and the mice of the 99 Tc m -HL91 group were then killed, the tumor, blood and organs were removed, weighted and the radioactivity was measured. ROIs were drawn around the tumor, head and chest in whole body planar images, and radioactivity ratios of tumor to head (T/H), chest (T/C) and contralateral limbs (T/L) were calculated. Results: No significant tumor radioactivity in 2 h and 4 h images of 99 Tc m -MIBI mice (T/C: 0.20 +- 0.08 and 0.14 +- 0.07) was found; increased tumor radioactivity was identified in images of 99 Tc m -HL91 mice (T/C: 3.25 +- 1.25 and 2.44 +- 1.07), and there was significant difference (t = 4.8 - 7.5, P 99 Tc m -HL91 in tumor tissue of mice is higher and clearance rate is slower. 99 Tc m -HL91 is a valuable tumor imaging agent for clinical diagnosis for the cancer

  13. Experimental research of 99Tcm-MIBI SPECT in detecting multidrug resistance status on tumor nude mice

    International Nuclear Information System (INIS)

    Hu Xudong; Ji Cheng; Wang Xiaoyue; Xu Jiaying; Fan Saijun; Yang Guoren

    2009-01-01

    Objective: To analyze 99 Tc m -MIBI images separately before and after VPL in nude mice bearing human lung tumors in order to find a feasible way in evaluating MDR status of tumor with 99 Tc m -MIBI image. Methods: Analysis of 99 Tc m -MIBI images was performed at 15 min, 60 min and 120 min after injecting 99 Tc m -MIBI 7.4 MBq in female BALB/c nude mice bearing human lung tumors. The tumor uptake rate (TUR) and retention rate (RI) were calculated and the data were analyzed. P-gp albumen ex-pression was determined by flow cytometry. Results: Significance difference in TUR was observed for at the 15th, 60th or 120th min between the imaging in the control group versus in the second imaging in VPL reverse group as well as between the first imaging and the second imaging in the reverse group. Furthermore, there was negative correlation between retention rate (RI) and P-gp albumen expression. Conclusion: These results for the first time demonstrate that the results of 99 Tc m -MIBI imaging exhibits a negative correlation to P-gp albumen expression, indicating that analysis of 99 Tc m -MIBI imaging may be a potential indicator for MDR status of tumor and can be used to monitoring the role of VPL in reverting the multidrug resistance. (authors)

  14. {sup 99m}Tc generator preparation using (n, {gamma}){sup 99}Mo produced ex-natural molybdenum

    Energy Technology Data Exchange (ETDEWEB)

    Le, So Van [Nuclear Research Institute, Dalat (Viet Nam)

    2003-03-01

    Theoretical assessment on the chromatographic {sup 99m}Tc generator preparation using (n, {gamma}) {sup 99}Mo produced ex-natural molybdenum was carried out. The relationship between the neutron flux for MoO{sub 3} target activation, Mo-content or Mo adsorption capacity of column packing material, {sup 99m}Tc pertechnetate concentration and/or {sup 99m}Tc radioactivity of eluate was established. The reasonably lower limit of neutron flux of reactor and Molybdenum content of column packing material were found out to estimate the production of portable chromatographic generators available for nuclear medicine application. The concentration of {sup 99m}Tc pertechnetate eluate of low {sup 99m}Tc concentration using the column elution technique was also evaluate theoretically and conducted successfully in practice. Three options of {sup 99m}Tc generator using Titanium-Molybdate, Zirconium-Molybdate and Zirconium Oxide as generator column-packing materials were prepared and successfully put into use in nuclear medicine application. (author)

  15. The Relation between Collateral Circulation and 99mTc-MIBI Heart SPECT

    International Nuclear Information System (INIS)

    Kim, Jae Man; Na, Deug Young; Park, Eun Kyung

    1994-01-01

    The coronary collateral vessels have revealed their significance in terms of reduction of infarct size, preservation left ventricular function, and prevention of left ventricular aneurysm in patients with myocardial infarction. The purpose of this study were to evaluated the relation between collateral circulation and 99m Tc-MIBI Heart SPECT in patient with acute myocardial infarction and their clinical significance. The fifty six MI patients with antegrade TIMI perfusion grade 0 and 1 were studied. The patients were classified into two groups; Group I included 30 patients with grade 2, 3 Collateral flow. Group II included 26 patients with grade 0, 1 Collateral flow. Collateral filling were graded from 0 to 3; 0- none, 1- Filling of side branch only, 2- Partial filling of the epicardial segment, 3- Complete filling of epicardial segment. Clinical variables, left ventricular function, 99m Tc-MIBI Heart SPECT were analyzed with angiographic finding. Results were following: 1) Collateral visualization was found to be greater in patient with involvement of right coronary artery (RCA). The collateral development site of infarct related artery was RCA 15 cases, left anterior descending artery (LAD) 10 cases, left circumflex artery (LCX) 5 cases, and the collateral circulation from LAD to RCA was 13 cases (40.6%). 2) There was a tendency to be decreased in peak CK activity with group I . 3) The presence of good collateral channels was more frequently 99m Tc-MIBI reversible perfusion defect (83.4% vs 15.3%, p 99m Tc-MlBI reversible perfusion defect.

  16. A comparison between 99Tcm-tetrofosmin and 99Tcm-MIBI myocardial perfusion imaging in detection of silent myocardial ischemia

    International Nuclear Information System (INIS)

    Fu Wei; Tang Yi; Liu Xuemei; Fan Yan; Liu Tao

    2012-01-01

    Objective: To compare 99 Tc m -tetrofosmin (TF) and 99 Tc m -MIBI adenosine stress/resting MPI in detection of silent myocardial ischemia (SMI). Methods: According to the WHO diagnostic criteria for coronary heart disease (CHD), 306 SMI patients were classified to three groups as type Ⅰ (n=122), type Ⅱ (n=112) and type Ⅲ (n=72). The subjects of each type were randomly divided into 2 subgroups; one subgroup underwent adenosine stress/rest MPI with 99 Tc m -MIBI and another subgroup with 99 Tc m -TF. The clinical diagnosis of CHD was proven with electrocardiogram (46 cases), dynamic electrocardiogram (219 cases) or CAG (41 cases). Comparison factors between the two tracers included image quality and diagnostic efficacy. The image quality was graded into three classes:excellent, good and moderate. χ 2 test and analysis of variance were used to analyze data. Results: The sensitivities of detecting myocardial ischemia with 99 Tc m -MIBI MPI and 99 Tc m -TF MPI in group type Ⅰ were 57.38% (35/61) vs 60.66% (37/61) (χ 2 =0.136, P>0.05); in group type Ⅱ 69.64% (39/56) vs 64.29% (36/56) (χ 2 =0.363, P>0.05) and in group type Ⅲ 83.33% (30/36) vs 88.89% (32/36) (χ 2 =0.465, P>0.05), respectively. There was no significant difference between the sensitivities of the two imaging modalities in all three types of SMI patients.In image quality grading, 99 Tc m -MIBI and 99 Tc m -TF demonstrated excellent images with 41.18% (63/153) vs 48.37% (74/153) (χ 2 =1.599, P=0.206), good with 45.10% (69/153) vs 34.64% (53/153) (χ 2 =3.489, P=0.062) and moderate with 13.72% (21/153) vs 16.99%(26/153) (χ 2 =0.628, P=0.428). There was no unqualified image with either modality. 99 Tc m -TF displayed quicker radioactivity clearance in liver and lungs. Thereby there was less interference or pitfalls present in the ventricle base or interior wall that may result from higher liver radioactivity retention. The waiting time between the tracer injection and imaging was at least 1 h

  17. Design of an X -band electron linear accelerator dedicated to decentralized 99Mo/99mTc supply: From beam energy selection to yield estimation

    Science.gov (United States)

    Jang, Jaewoong; Yamamoto, Masashi; Uesaka, Mitsuru

    2017-10-01

    The most frequently used radionuclide in diagnostic nuclear medicine, 99mTc, is generally obtained by the decay of its parent radionuclide, 99Mo. Recently, concerns have been raised over shortages of 99Mo/99mTc, owing to aging of the research reactors which have been supplying practically all of the global demand for 99Mo in a centralized fashion. In an effort to prevent such 99Mo/99mTc supply disruption and, furthermore, to ameliorate the underlying instability of the centralized 99Mo/99mTc supply chain, we designed an X -band electron linear accelerator which can be distributed over multiple regions, whereby 99Mo/99mTc can be supplied with improved accessibility. The electron beam energy was designed to be 35 MeV, at which an average beam power of 9.1 kW was calculated by the following beam dynamics analysis. Subsequent radioactivity modeling suggests that 11 of the designed electron linear accelerators can realize self-sufficiency of 99Mo/99mTc in Japan.

  18. Design of an X-band electron linear accelerator dedicated to decentralized ^{99}Mo/^{99m}Tc supply: From beam energy selection to yield estimation

    Directory of Open Access Journals (Sweden)

    Jaewoong Jang

    2017-10-01

    Full Text Available The most frequently used radionuclide in diagnostic nuclear medicine, ^{99m}Tc, is generally obtained by the decay of its parent radionuclide, ^{99}Mo. Recently, concerns have been raised over shortages of ^{99}Mo/^{99m}Tc, owing to aging of the research reactors which have been supplying practically all of the global demand for ^{99}Mo in a centralized fashion. In an effort to prevent such ^{99}Mo/^{99m}Tc supply disruption and, furthermore, to ameliorate the underlying instability of the centralized ^{99}Mo/^{99m}Tc supply chain, we designed an X-band electron linear accelerator which can be distributed over multiple regions, whereby ^{99}Mo/^{99m}Tc can be supplied with improved accessibility. The electron beam energy was designed to be 35 MeV, at which an average beam power of 9.1 kW was calculated by the following beam dynamics analysis. Subsequent radioactivity modeling suggests that 11 of the designed electron linear accelerators can realize self-sufficiency of ^{99}Mo/^{99m}Tc in Japan.

  19. Clinical Characteristics and Findings of 99mTc-MIBI Heart SPECT in Patients with Acute Myocardial Infarction with Normal Coronary Arteriography

    International Nuclear Information System (INIS)

    Park, Myung Jae; Choi, Tae Youl; Kim, Deong Yoon; Kang, Heung Sun; Choue, Chung Whee; Kim, Kwon Sam; Kim, Kwang Won; Kim, Myung Shick; Song, Jung Sang; Bae, Jong Hoa

    1993-01-01

    Among 64 patients with acute myocardial infarction who underwent coronary angiography, 7 patients (10.9%)showed normal coronary artery. Six patients were men and 1 patient was female. The mean age of patients were 31.1 ± 3.9 years. Among the risk factors of coronary heart disease, smoking was most probable factor in patients with acute myocardial infarction with normal coronary angiography. 99m Tc-MIBI heart SPECT performed 5 of 7 patients and showed that it could be used in diagnosis, localization, extent of infarct area in patients with acute myocardial infarction with normal coronary angiography. But follow up 99m Tc-MIBI heart SPECT study will be needed to define the ability of myocardial viability in this patients.

  20. Magnesium-Molybate Compounds as Matrix for 99Mo/99mTc Generators

    Directory of Open Access Journals (Sweden)

    Fabiola Monroy-Guzman

    2011-01-01

    Full Text Available This work reports the preparation of a 99mTc generator based on conversion of 99Mo produced by neutron irradiation, into insoluble magnesium 99Mo-molybdates compounds as matrix. The effect of magnesium salt types and concentration, Mg:Mo molar ratios, pH of molybdate solutions, eluate volume as well as the addition order of molybdate and magnesium solutions’ influences on the final 99mTc were evaluated. Polymetalates and polymolybdates salts either crystallized or amorphous were obtained depending on the magnesium salt and Mg:Mo molar ratio used in matrix preparation. 99Mo/99mTc generator production based on magnesium-99Mo molybdate compounds allow reduction of preparation time and eliminates the use of specialized installations. The best generator performances were attained using matrices prepared from 0.1 mol/L MgCl2·6H2O solutions, ammonium molybdate solutions at pH 7 and at a Mg:Mo molar ratio of 1:1.

  1. Isolation and labelling of human leucocytes with sup(99m)Tc

    International Nuclear Information System (INIS)

    Kalbaek, H.

    1986-01-01

    The role of the leucocyte isolation procedure on cell labeling with sup(99m)Tc has been evaluated. Separation of leucocytes was performed by two procedures: (1) sedimentation on methyl cellulose, followed by discontinuous gradient centrifugation; (2) methyl cellulose sedimentation and hypotonic haemolysis of residual red blood cells. After washing the cells in saline and incubation with a stannous pyrophosphate agent, the leucocytes were labelled with 5-10 mCi sup(99m)Tc. Procedure 1 gave a higher purity but lower recovery of polymorphonuclear leucocytes, and a minor contamination of red blood cells. sup(99m)Tc labelling of cells was slightly more efficient with this method, probably due to the presence of red blood cells. Procedure 1 is recommended for in vitro studies on cell kinetics and procedure 2 is recommended for clinical use. (orig.)

  2. Comparison of 99mTc-MIBI scanning and sentinel node biopsy in the detection of occult melanoma lymph node metastases

    International Nuclear Information System (INIS)

    Alonso, O.; Lago, G.; Lopes de Amorim, M.C.; Juri, C.; Larre Borges, A.; Martinez, M.; De Boni, D.; Espasandin, J.; Priario, J.

    2002-01-01

    Aim: Sentinel node biopsy (SNB) is a highly accurate technique for detecting occult metastatic disease in the regional lymph nodes. Our group has reported that 99m Tc-MIBI scintigraphy is an imaging technique that can detect clinically undetectable metastases. This prospective study shows preliminary results on the comparison of both techniques for the detection of lymph node invasion. Material and Methods: Twenty-two consecutive patients (15 women, 7 men; mean age, 55 years) with primary melanoma > 1.0 mm thick were enrolled (mean 2.6 mm). Patients underwent 99m Tc-MIBI scintigraphy of regional lymph nodes 1-2 weeks before surgery, acquiring 10-minute planar images with a LFOV gamma camera. A preoperative lymphoscintigraphy using 99m Tc-colloidal (Re) sulphide was performed the day before surgery, using a dose of 74-93 MBq. Radio guided SNB was performed with a hand-held gamma probe. Lymph nodes were examined histologically and immunostained for S-100 and HMB-45. Results: The sentinel node (SN) was identified in 21/22 patients. An average of 1.6 SN/lesion were harvested from melanomas located in the following regions: head and neck (n=3), trunk (n=6), extremities (n=12). All patients with negative SN (n=11) were also negative with MIBI. In 10 cases the SN demonstrated metastatic involvement, whereas 99m Tc-MIBI was positive in 8 of them (80%). In cases with positive SN/negative 99m Tc-MIBI, the pathology report revealed micro metastatic disease. Conclusion: These preliminary results suggest that 99m Tc-MIBI scanning has the potential of selecting a group of patients who might benefit from a selective complete lymphadenectomy

  3. Separation of sup(99m)Tc from 99Mo through a hydrous zirconium oxide column

    International Nuclear Information System (INIS)

    Mengatti, J.

    1980-01-01

    The preparation of 99 Mo-,sup(99m)Tc generator based on the adsorption of 99 Mo on hydrous zirconium oxide column, employing the in exchange technique, is described. The adsorption of 99 Mo on hydrous zirconium oxide (HZO) and the separation of sup(99m)Tc, generated by the decay of 99 Mo with saline solution, are analised. The sup(99m)Tc separation yield, pH of the eluted solution, aspect of the elution curve and the adsorption of 99 Mo on hydrous zirconium oxide calcined at 800 0 C are studied. The chemical and radioactive purities of the final product are analysed and the variation of the elution yield for successive elutions is studied. (Author) [pt

  4. Stress/Rest Tc-99m-MIBI SPECT in Comparison with Rest/Stress Rubidium - 82 PET

    International Nuclear Information System (INIS)

    Lee, D. S.; Kamg, K. W.; Lee, K. H.; Jeong, J. M.; Kwark, C. E.; Chung, J. K.; Lee, M.C.; Seo, J. D.; Koh, C. S.

    1995-01-01

    We compared stress/rest myocardial Tc-99m-MIBI tomographic image findings with rest/stress rubidium-82 tomographic images. In 23 patients with coronary artery disease (12 of them received bypass grafts before) and 6 normal subjects, rest rubidium PET study was performed, rubidium-82 and Tc-99m-MIBI were injected simultaneously to each patient after dipyridamole stress for rubidium PET and MIBI SPECT; and rest MIBI SPECT was performed 4 hours thereafter. We scored segmental decrease of rubidium, or MIBI uptakes into 5 grades for 29 segments from 3 short-axis, vertical and horizontal slices. Scores were summed for each major arterial territory. When more score than two grade-2's or one grade-3 was considered as the cue for significant stenosis for major arterial territories, 67% of 46 stenosed arteries were found with MIBI studies and 78% of them by rubidium studies. Fourteen among 28 grafted arterial territories of 12 post-CABG patients were found normal with both rubidium and MIBI. Segmental scores were concordant between rubidium and MIBI in 72% of 709-stress segments and in 80% of 825 rest segments. Stress rubidium segmental scores were less than stress MIBI scores in 9%, so were rest rubidium scores. Stress rubidium scores were more than stress MIBI scores in 20% of segments, and rest rubidium segmental scores were more than rest MIBI scores in 11%. Rank correlations (Spearman's rho's more than 0.7(stress) and 0.5(rest), slopes (MIBI/rubidium) around 0.7(stress) and 0.9(rest) suggested deeper and wider defects in stress with rubidium. Slope over 1 (MIBI/rubidium) with LAD segmental scores at rest and 7 territories which had much larger score with MIBI revealed exaggeration of rest defects with rest MIBI in same-day stress/rest study. Difference scores (stress-rest for each territory) suggesting ischemia were larger with rubidium (slope of MIBI/rubidium around 0.45). As has been implied by animal or separate-day- human studies, these segmental analyses with

  5. Evaluation of Cardiac Mitochondrial Function by a Nuclear Imaging Technique using Technetium-99m-MIBI Uptake Kinetics

    International Nuclear Information System (INIS)

    Matsuo, Shinro; Nakajima, Kenichi; Kinuya, Seigo

    2013-01-01

    Mitochondria play an important role in energy production for the cell. The proper function of a myocardial cell largely depends on the functional capacity of the mitochondria. Therefore it is necessary to establish a novel and reliable method for a non-invasive assessment of mitochondrial function and metabolism in humans. Although originally designed for evaluating myocardial perfusion, 99m Tc-MIBI can be also used to evaluate cardiac mitochondrial function. In a clinical study on ischemic heart disease, reverse redistribution of 99m Tc-MIBI was evident after direct percutaneous transluminal coronary angioplasty. The presence of increased washout of 99m Tc-MIBI was associated with the infarct-related artery and preserved left ventricular function. In non-ischemic cardiomyopathy, an increased washout rate of 99m Tc-MIBI, which correlated inversely with left ventricular ejection fraction, was observed in patients with congestive heart failure. Increased 99m Tc-MIBI washout was also observed in mitochondrial myopathy, encephalopathy, lactic acidosis and stroke-like episodes (MELAS) and in doxorubicin-induced cardiomyopathy. Noninvasive assessment of cardiac mitochondrial function could be greatly beneficial in monitoring possible cardiotoxic drug use and in the evaluation of cardiac damage in clinical medicine

  6. Achalasia diagnosed by {sup 99m}Tc pertechnetate scintigraphy; Diagnose einer Achalasie durch {sup 99m}Tc-Pertechnetat-Szintigraphie

    Energy Technology Data Exchange (ETDEWEB)

    Mikosch, P. [Landeskrankenhaus Klagenfurt (Austria). Abt. fuer Nuklearmedizin und Spezielle Endokrinologie; Gallowitsch, H.J. [Landeskrankenhaus Klagenfurt (Austria). Abt. fuer Nuklearmedizin und Spezielle Endokrinologie; Kresnik, E. [Landeskrankenhaus Klagenfurt (Austria). Abt. fuer Nuklearmedizin und Spezielle Endokrinologie; Lind, P. [Landeskrankenhaus Klagenfurt (Austria). Abt. fuer Nuklearmedizin und Spezielle Endokrinologie

    1997-06-01

    A 73-year-old patient presented a {sup 99m}Tc scintiscan with a focal tracer accumulation left and caudal of the thyroid gland. Further investigations with sonography, CT, esophagoscopy and barium swallow provided the diagnosis of achalasia as the reason for focal {sup 99m}Tc retention caudal of the thyroid gland. Explanation for {sup 99m}Tc accumulation within the esophagus may be the nonspecific accumulation of {sup 99m}Tc not only in the thyroid gland but also in the salivary glands. Excretion of the tracer follows with the saliva. Structural and motor disorders of the esophagus can thus lead to focal tracer retention within the esophagus simulating thyroid tissue. (orig.) [Deutsch] Eine 73jaehrige Patientin zeigte bei der {sup 99m}Tc-Schilddruesenszintigraphie eine von der Schilddruese abgesetzte deutliche fokale Speicherung links kaudal der Schilddruese. Die weitere diagnostische Abklaerung mittels Sonographie, CT, Oesophagoskopie und videoassistiertem Kontrastmittelschluckakt ergab als Ursache der {sup 99m}Tc-Speicherung eine Achalasie. Die Erklaerung einer {sup 99m}Tc-Speicherung in der Speiseroehre waere die unspezifische {sup 99m}Tc-Aufnahme in den Speicheldruesen mit nachfolgender Tracerelimination ueber den Speichel. Depotbildungen von Speichel bei Erkrankungen der Speiseroehre, die mit einer Transportstoerung des Speichels verbunden sind, koennen dadurch Schilddruesengewebe vortaeuschen. (orig.)

  7. Detecting culprit vessel of coronary artery disease with SPECT 99Tcm-MIBI myocardial imaging

    International Nuclear Information System (INIS)

    Luan Zhaosheng; Zhou Wen; Peng Yong; Su Yuwen; Tian Jianhe; Gai lue; Sun Zhijun

    2002-01-01

    Objective: To assess the value of detecting culprit vessel of coronary artery disease (CAD) with SPECT 99 Tc m -MIBI myocardial imaging. Methods: Forty-six patients with CAD were studied. Every patients had multiple-vessel lesion showed by coronary arteriography and was treated by revascularization as percutaneous transluminal angioplasty (PTCA), coronary artery bypass graft (CABG) or laser holing. Exercise (EX), rest (RE) and intravenous infusion of nitroglycerine (NTG) SPECT 99 Tc m -MIBI myocardial imagings were performed before revascularization. Exercise and rest images revealed the myocardial ischemia. NTG images revealed myocardial viability. Culprit vessels were detected according to the defects showed by above mentioned images. The veracity of detected culprit vessels was tested with the outcome of the reperfusion therapy. Results: In this group, the coronary arteriography revealed 107 lesioned coronary arteries. Myocardial imaging detected 46 culprit vessels including 23 left anterior descending (LAD), 19 left circumflex coronary artery (LCX) and 4 right coronary artery (RCA). All 46 culprit vessels underwent revascularization and had nice outcome. The veracity of 99 Tc m -MIBI myocardial imaging detected culprit vessels was high according to patients' outcome. Conclusion: Exercise, rest and NTG 99 Tc m -MIBI myocardial imaging is a great method for detecting culprit vessels in multivessel coronary disease

  8. The separation of sup(99m)Tc from 99Mo through an aluminium oxide chromatographic columm

    International Nuclear Information System (INIS)

    Imoto, S.T.

    1980-01-01

    The separation of sup(99m)Tc from 99 Mo using the chromatographic method is studied. Alumina is used as adsorbent. The pH values for adsorption of carrier-free 99 Mo on columns filled with ordinary alumina and with that thermically treated at 1000 0 C for five hours, and the separation conditions of sup(99m)Tc using physiologic solution as eluent are determined. The sup(99m)Tc separation yields of both columns are compared and the quality of the products obtained by successive elutions for 10 days is analyzed. (Author) [pt

  9. A comparative study of 99mTc-HL91 and 99mTc-MIBI imaging in experimental tumor and inflammatory models

    International Nuclear Information System (INIS)

    Cao, W.; Zhang, X.Y.; An, R.

    2002-01-01

    Aim: 99m Tc-HL91 is a newly developed hypoxic imaging agent for ischemic myocardium and tumor imaging. 99m Tc-MIBI is one of imaging agent for mammary tumor imaging. The aim of this experiment is to evaluate the diagnostic value of 99m Tc-HL91 in detection of solid tumor in experimental tumor and inflammatory models, via comparative study with 99m Tc-MIBI. Material and Methods: HL91 kits was provided by China Nine Star Co. Three kinds of bearing solid neoplasm mice groups (bearing Ehrlich carcinoma mice, bearing H 22 carcinoma mice and bearing human ovarian COC 1 neoplasm nude mice) and two inflammatory model groups (chemical and bacterial inflammation) underwent static whole body planar images at 1 and 4 hours post injection of 99m Tc-HL91. Two kinds of bearing neoplasm mice groups (bearing Ehrlich carcinoma mice, bearing H 22 carcinoma mice) and two inflammatory model groups (chemical and bacterial inflammation) underwent static planar images post injection of 99m Tc-MIBI, at early phase (10∼20 minutes) and delayed phase (2 hrs). All of mice were sacrificed at 4 hrs. The tumors, or inflammatory lesions, blood and contralateral muscles were removed, weighed and the radioactivity was measured. Regions of interesting (ROIs) were drawn around tumor, inflammatory lesions and contralateral muscles in planar images, and the radioactivity ratios of target (tumor or inflammatory lesions)-to-blood (T/B), target-to-non target (contralateral muscles) i. e. T/NT was calculated. Results: Neoplasm can be clearly visible in planar images at 1hr and 4 hrs post injection of 99m Tc-HL91 in all tumor models. At same time inflammatory lesions cannot be seen clearly. Neoplasm can be seen in delayed phase in 99m Tc-MIBI groups, but not easy to distinguish them from inflammation. Conclusion: Compared with 99m Tc-MIBI imaging, 99m Tc-HL91 has much more diagnostic value in detection of solid neoplasm, and can distinguish neoplasm from inflammation

  10. Relationship between the 99mTc-MIBI and expression of P-glycoprotein in lung cancer

    International Nuclear Information System (INIS)

    Meng Zili; Shen Zhenya

    2002-01-01

    Objective: To correlate the imaging of 99m Tc-MIBI with the expression of P-glycoprotein (PGP) in lung cancer. Methods: All patients, undergoing early (30 min) and delayed (3h) 99m Tc-MIBI imaging before initiation of chemo-or radiotherapy, were diagnosed pathologically. Immunohistochemical studies were performed using a monoclonal antibody, P-170, developed against the internal epitope of PGP. Normal tissue and tumor washout rate and tumor-to-background ratio were correlated with the level of PGP expression. Results: There was an inverse correlation between tumor-to-background ratio and the density of PGP (P 0.1). Conclusion: The reduced ability for the tumors to accumulate MIBI correlates well with the increased levels of PGP expression, tumor washout rate of MIBI does not correlate with the density of PGP in tumor tissues

  11. Discussion on twenty-two hepatobiliary scintigraphs performed with technetium 99m-labelled N-(2,6 dimethylphenylcarbamoylmethyl) iminodiacetic acid (or HIDA-99mTc) at the Val-de-Grace Army Instruction Hospital

    International Nuclear Information System (INIS)

    Hoste, Philippe.

    1978-12-01

    Intraveinously injected technetium 99m-labelled N-(2,6 dimethyl-phenylcarbamoylmethyl) iminodiacetic acid, or HIDA-99mTc, is taken up by the hepatocytes and secreted in the bile, a fraction being normally eliminated by the kidneys. Isotopic examination with HIDA-99mTc gives valuable information on the morphology of the liver during the first minutes of the test, thus revealing the presence of parenchyma disease. In all observed cases of secondary hepatic localisations in particular the HIDA-99mTc images overlie those obtained with technetium colloids. By the examination it is also possible: - to establish the existence or otherwise of a functional vesicle, - to follow the path of the radiotracer along the bile duct. In short, HIDA-99mTc hepatobiliary scintigraphy is particularly useful for the study of hepatocyte uptake and bile elimination since it allows a continuous quantitative study of the liver-bile function under given physiological conditions [fr

  12. An expedient method for the preparation of 99mTc-MIBI and 99mTc-MAG3 using microwave and teflon 'bomb'

    International Nuclear Information System (INIS)

    Varelis, P.; Poot, M.T.

    1998-01-01

    Full text: The recommended method for the preparation of 99mTc-MIBI and 99mTc-MAG3 requires that they be heated in a boiling water bath for 10 minutes, after reconstitution with sodium pertechnetate. This method is both inconvenient and time consuming. A more rapid and convenient method for the preparation of these radiopharmaceuticals employs a conventional microwave oven. However, a serious limitation of this method is the hazard associated with an explosion of a vessel containing a radioactive substance. Traditionally, mixtures that can potentially explode are contained in a device called a 'bomb'. We have developed a method, utilising such a device, that allows us to rapidly and safely prepare 99mTc-MIBI and 99mTc-MAG3 using a microwave oven. This device is used in our department on a daily basis. Since using the teflon bomb, there has been one incidence of an explosion, which was successfully contained within the bomb. There was no statistically significant difference between the radiochemical purity (RCP) of the microwave prepared samples and those obtained using the recommended method. In conclusion, 99mTc-MIBI and 99mTc-MAG3 can be safely prepared and quality controlled in under ten minutes using a microwave oven and our teflon bomb. The average RCP for 99mTc-MIBI and 99mTc-MAG3 prepared using a microwave oven were 97.0+2.0% (n=19) and 99.8+0.2 (n=7) respectively

  13. An expedient method for the preparation of 99mTc-MIBI and 99mTc-MAG3 using microwave and teflon `bomb`

    Energy Technology Data Exchange (ETDEWEB)

    Varelis, P.; Poot, M.T. [St George Hospital, Sydney, NSW (Australia). Department of Nuclear Medicine

    1998-06-01

    Full text: The recommended method for the preparation of 99mTc-MIBI and 99mTc-MAG3 requires that they be heated in a boiling water bath for 10 minutes, after reconstitution with sodium pertechnetate. This method is both inconvenient and time consuming. A more rapid and convenient method for the preparation of these radiopharmaceuticals employs a conventional microwave oven. However, a serious limitation of this method is the hazard associated with an explosion of a vessel containing a radioactive substance. Traditionally, mixtures that can potentially explode are contained in a device called a `bomb`. We have developed a method, utilising such a device, that allows us to rapidly and safely prepare 99mTc-MIBI and 99mTc-MAG3 using a microwave oven. This device is used in our department on a daily basis. Since using the teflon bomb, there has been one incidence of an explosion, which was successfully contained within the bomb. There was no statistically significant difference between the radiochemical purity (RCP) of the microwave prepared samples and those obtained using the recommended method. In conclusion, 99mTc-MIBI and 99mTc-MAG3 can be safely prepared and quality controlled in under ten minutes using a microwave oven and our teflon bomb. The average RCP for 99mTc-MIBI and 99mTc-MAG3 prepared using a microwave oven were 97.0+2.0% (n=19) and 99.8+0.2 (n=7) respectively

  14. A {sup 99m}Tc Generator using PZC for (n,{gamma}) {sup 99}Mo

    Energy Technology Data Exchange (ETDEWEB)

    Adang, H G; Mutalib, A; Suparman, I; Hamid,; Purwadi, B; Pancoko, M; Setiowati, S; Yulianti, V; Robertus, D H [Radioisotope Production Center, National Atomic Energy Agency Kawasan PUSPIPTEK, Serpong (Indonesia)

    1998-10-01

    The high performance adsorbent Poly Zirconium Compound (PZC) was produced by Department of Radioisotope, Japan Atomic Energy Research Institute. This compound was developed as an adsorbent for natural Mo (n,{gamma}) {sup 99}Mo-{sup 99m}Tc Generator. In the present paper, we report the performance of the PZC for a {sup 99m}Tc Generator which was focused on the yield, on elution profile and {sup 99}Mo breakthrough. (author)

  15. THE CLINICAL SIGNIFICANCE OF 99mTc-MIBI BREAST IMAGING IN THE DIAGNOSIS OF EARLY BREAST CANCER

    Institute of Scientific and Technical Information of China (English)

    任长才; 金少津; 邹强; 朱汇庆; 王红鹰; 梁春立

    2001-01-01

    Objective: To find an effective, sensitive, specific and noninvasive diagnostic method of breast cancer. Methods: 109 masses of 102 patients with breast lesions smaller than 2 cm in diameter were divided into three groups to undergo 99mTc-MIBI imaging and compared with the results of pathology examination. 20 cases without breast lesions were selected as control. Abnormal condensation of 99mTc-MIBI in the breast reaching 10% higher than that in the counterpart of the healthy breast was regarded as positive. Results: Of 32 breast cancers, positive imaging appeared in 25. Negative imaging were found in 31 of 38 benign breast lesions. Of 39 occult breast lesions, positive imaging appeared in 6 and 3 of them were breast cancer, 2 of 3 patients with slightly increased 99mTc-MIBI imaging threshold were breast cancer also. No positive imaging was found in the control group. The diagnostic accuracy, sensitivity, specificity, positive predictive value, negative predictive value of 99mTc-MIBI was 88.4%, 89.2%, 88.0%, 75.0% and 95.3%, respectively. Conclusion: 99mTc-MIBI imaging had higher sensitivity and accuracy in the diagnosis of breast cancer and differentiation between benign and malignant breast lesions. It could provide useful information for the diagnosis of clinically suspected breast cancer.

  16. 99mTc-MIBI/123I-Na subtraction scanning for localized parathyroid adenoma in patients with asymptomatic/mild primary hyperparathyroidism

    International Nuclear Information System (INIS)

    Tanaka, Yuji; Funahashi, Hiroomi; Imai, Tsuneo

    1996-01-01

    Primary hyperparathyroidism is most commonly detected as a mild elevation of the serum calcium concentration. In the present study, the utility of 99m Tc-methoxyisobutylisonitrile (MIBI) imaging before initial surgery was evaluated for localizing abnormal parathyroid glands in patients with asymptomatic and mild primary hyperparathyroidism. The results were compared with those of thallium-technetium subtraction scanning (TTSS). 99m Tc-MIBI/ 123 I-Na subtraction scanning was performed in 11 patients, and TTSS was performed in 10 of them. The sensitivity was 100% and the positive predictive value was 92% for 99m Tc-MIBI/ 123 I-Na, while the sensitivity was 50% and the positive predictive value was 100% for TTSS. The smallest gland detected weighed 85 mg in 99m Tc-MIBI/ 123 I-Na, and 570 mg in TTSS. There was a difference between the median weight of adenomas which were detected by 99m Tc-MIBI/ 123 I-Na (754 mg), and those which were detected by TTSS (1,195 mg). These results suggest that TTSS parathyroid scintigraphy could give way to 99m Tc-MIBI/ 123 I-Na parathyroid scintigraphy for improved detection of low-weight abnormal parathyroid glands. (author)

  17. Photo-production of (99)Mo/(99m)Tc with electron linear accelerator beam.

    Science.gov (United States)

    Avagyan, R; Avetisyan, A; Kerobyan, I; Dallakyan, R

    2014-09-01

    We report on the development of a relatively new method for the production of (99)Mo/(99m)Tc. The method involves the irradiation of natural molybdenum using high-intensity bremsstrahlung photons from the electron beam of the LUE50 linear electron accelerator located at the Yerevan Physics Institute (YerPhi). The production method has been developed and shown to be successful. The linear electron accelerator at YerPhi was upgraded to allow for significant increases of the beam intensity and spatial density. The LUE50 was also instrumented by a remote control system for ease of operation. We have developed and tested the (99m)Tc extraction from the irradiation of natural MoO3. This paper reports on the optimal conditions of our method of (99)Mo production. We show the success of this method with the production and separation of the first usable amounts of (99m)Tc. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Diversification in the Supply Chain of (99)Mo Ensures a Future for (99m)Tc.

    Science.gov (United States)

    Cutler, Cathy S; Schwarz, Sally W

    2014-07-01

    The uncertain availability of (99m)Tc has become a concern for nuclear medicine departments across the globe. An issue for the United States is that currently it is dependent on a supply of (99m)Tc (from (99)Mo) that is derived solely by production outside the United States. Since the United States uses half the world's (99)Mo production, the U.S. (99)Mo supply chain would be greatly enhanced if a producer were located within the United States. The fragility of the old (99)Mo supply chain is being addressed as new facilities are constructed and new processes are developed to produce (99)Mo without highly enriched uranium. The conversion to low-enriched uranium is necessary to minimize the potential misuse of highly enriched uranium in the world for nonpeaceful means. New production facilities, new methods for the production of (99)Mo, and a new generator elution system for the supply of (99m)Tc are currently being pursued. The progress made in all these areas will be discussed, as they all highlight the need to embrace diversity to ensure that we have a robust and reliable supply of (99m)Tc in the future. © 2014 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  19. Transport of /sup 99m/Tc complexes through the blood-brain barrier

    International Nuclear Information System (INIS)

    Loberg, M.D.; Corder, E.H.; Fields, A.T.; Callery, P.S.

    1979-01-01

    Thirteen /sup 99m/Tc complexes have been synthesized and used to determine the relationships between protein binding, lipophilicity and membrane transport. The lipophilicity of the /sup 99m/Tc complexes was altered by adding substituents to either IDA, EDTA, DTPA or oxine; membrane transport was estimated using the brain uptake index (BUI) method. The BUI of the /sup 99m/Tc complexes was found to vary directly with lipophilicity and inversely with protein binding. These results demonstrated that /sup 99m/Tc-oxine derivatives are better suited for use in the development of intracellular tracers than are the /sup 99m/Tc derivatives of aminopolycarboxylates

  20. Simulation of a gamma-camera for activity measurement of {sup 99m}Tc using the Monte Carlo Gate code; Simulação de uma gama-câmara para medidas de atividade de {sup 99m}Tc com o código de Monte Carlo Gate

    Energy Technology Data Exchange (ETDEWEB)

    Barrientos, C.P. Castro; Souza-Santos, D. [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Mação Junior, J.L.; Wunder, R.S.; Knust, I.C., E-mail: car_pcb@aluno.ird.gov.br [Hospital Naval Marcílio Dias, Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Brazil has a growing demand for nuclear medicine services (NMS), and radiopharmaceuticals supplied by the National Nuclear Energy Commission (CNEN) provide approximately two million nuclear medicine (NM) procedures per year. Among these radiopharmaceuticals, one of the most used is {sup 99m}Tc. The manipulation of unsealed radioactive sources presents a risk of incorporation. Workers who handle radiopharmaceuticals in NM procedures should be subject to an internal individual monitoring program to optimize their practices as well as to ensure that dose limits are not exceeded. This program may require measuring the activity of incorporated radionuclides, done in a whole body counter. This measurement may prove impracticable due to the absence of dedicated systems, available to all workers in a country. One solution to this problem would be to perform the measurement of the incorporated activity using the Gamma camera of the NMS in which the occupationally exposed individual (IOE) works. The objective of this work is to simulate with the Monte Carlo method a Gamma camera, with the code Gate, validating the results for the {sup 99m}Tc through measurements performed in an NMS. Measurements of counts were taken around the 140 keV main peak, with and without the collimator, that were correlated with the source activity. The validation shows good agreement between the simulation and the experimental data, with a difference of about 3% for the simulation without the collimator and about 2% for the simulation with the collimator. (author)

  1. Investigations on the structures of sup(99m)Tc and 113Sn pyrophosphate complexes and of sup(99m)Tc and 113Sn ethane hydroxy diphosphate complexes

    International Nuclear Information System (INIS)

    Hohloch, M.

    1980-01-01

    The complex formation of double labelling of bivalent 113 Sn and reduced, quadrovalent sup(99m)Tc with pyrophosphate (PPi) or ethane hydroxy diphosphorate (EHDP) has been investigated by means of in vivo distribution in the rat. The molar rates of sup(99m)Tc and 113 Sn to PPi resp. EHDP, as well as the pH-value and the initial concentration is varied. Furthermore, both elements were oxidized with H 2 O 2 in the alkaline medium. Four typical sup(99m)Tc and two typical 113 Sn in-vivo distribution patterns can be differentiated: 1. Pertechnetate, characterized by a strong enrichment in the stomach, forms when all Sn-II has been oxidized to Sn-IV in the preparation. 2. One bone-seeking 113 Sn-II PPi (EHDP) complex and a sup(99m)Tc-IV PPi (EHDP) complex each, which are formed at least equimolar ratio of Sn to PPi (EHDP) and suffiently high concentration of PPi (EHDP) in the physiological pH-value. 3. A non-bone-seeking sup(99m)Tc-IV compound, which is enriched in the kidneys instead, is formed in the weakly alkaline medium or at low PPi (EHDP) concentration. This is probably monomeric technetium dioxide dihydrate. 4. A sup(99m)Tc as well as a Sn colloid is formed at deficient ligand concentration (PPi or EHDP to Sn). The chemical composition of the complexes is discussed the possible reaction courses are illustrated in the following diagrams. (orig./MG) [de

  2. Rapid radiochemical methods for preparation of sup(99m)Tc labelled compounds

    International Nuclear Information System (INIS)

    Narasimhan, D.V.S.; Banodkar, S.M.; Kothari, K.; Mani, R.S.

    1981-01-01

    Several inorganic and organic compounds incorporating sup( 99 m)Tc are being extensively used for imaging various body organs. The preparation of these sup( 99 m)Tc compounds with the necessary purity requirements is carried out by controlled reduction of sup( 99 m)Tc-pertechnetate using Sn(II) ions as the reducing agent followed by complexation with various active ingredients. The authors here present procedures developed at Radiopharmaceuticals Section of BARC for preparing sup( 99 m)Tc-diphosphonate, sup( 99 m)Tc-glucoheptonate, sup( 99 m)Tc-albumin microspheres and sup( 99 m)Tc-phytate with high radiochemical purity. The paper also describes procedures for the preparation of freeze-dried kits for single step preparation of these compounds. The paper also describes the authors' experience with various analytical procedures for the determination of radiochemical purity of these preparations. (author)

  3. Detection and localization of enlarged parathyroid glands in patients with hyperparathyroidism using 99mTc-methoxyisobutylisonitrile (MIBI). A study of subtraction scintigraphy with 99mTc-pertechnetate

    International Nuclear Information System (INIS)

    Katagiri, Makoto; Ohtawa, Takahiro; Otsuka, Nobuaki; Morita, Koichi; Sone, Teruki; Mimura, Hiroaki; Yanagimoto, Shinichi; Fukunaga, Masao; Harada, Tanekazu

    1995-01-01

    In this study we investigated the detectability of abnormal parathyroid gland(s) by 99m Tc-methoxy-isobutylisonitrile (MIBI) scintigraphy in patients with hyperparathyroidism. The subjects were 6 patients with primary hyperparathyroidism (PHP) with a single adenoma and 13 patients with renal hyperparathyroidism (RHP) on chronic maintenance hemodialysis. The imaging data of 99m Tc-pertechnetate were subtracted from those of 99m Tc-MIBI (MIBI-Tc), and number and location of the positive images on scintigrams were compared with those obtained by conventional scintigraphy using 201 Tl-Cl and 99m Tc-pertechnetate (Tl-Tc). All of the patients underwent surgery, and the number and location of the abnormal parathyroid glands were confirmed. The number of resected parathyroid glands were 6 in PHP and 52 in RHP. The detectability of MIBI-Tc was 83.3% in PHP and 51.9% in RHP, while that of Tl-Tc was 100% and 44.2%, respectively. Although no statistically significant difference in the detectability was found between MIBI-Tc and Tl-Tc, the number of false positives with MIBI-Tc was less than that with Tl-Tc. The detectability of MIBI-Tc depended on the size of the parathyroid gland. The maximal diameter and weight of the smallest parathyroid gland detected were 15 mm and 290 mg in PHP, and 9 mm and 50 mg in RHP. The existence of the thyroid gland did not reduce the detectability of MIBI-Tc. In conclusion, MIBI-Tc was clinically very useful for the detection of abnormal parathyroid glands in patients with hyperparathyroidism. (author)

  4. 99mTc-MIBI SPECT in small call lung cancer patients before chemotherapy and after unresponsive chemotherapy

    International Nuclear Information System (INIS)

    Yamamoto, Yuka; Nishiyama, Yoshihiro; Fukunaga, Kotaro; Satoh, Katashi; Fujita, Jiro; Ohkawa, Motoomi

    2001-01-01

    We evaluated the accumulation of 99m Tc-MIBI in small cell lung cancer patients before chemotherapy and after unresponsive chemotherapy. The pre-chemotherapeutic group included 22 newly diagnosed patients. These patients underwent a 99m Tc-MIBI SPECT study before starting chemotherapy. After chemotherapy, based on changes in tumor size, three different patterns of response (complete remission: CR, partial remission: PR and no change: NC) were defined. The post-chemotherapeutic group included 11 patients after chemotherapy who did not respond to chemotherapy. These patients underwent a 99m Tc-MIBI SPECT study after completion of chemotherapy. SPECT images were acquired 15 min (early) and 2 hr (delayed) after injection of 99m Tc-MIBI. With a region of interest technique, the early ratio, delayed ratio and retention index were calculated. Early and delayed ratios in pre-chemotherapeutic patients were significantly higher than those in post-chemotherapeutic patients. There were no significant differences between the pre-chemotherapeutic and post-chemotherapeutic patients in the retention index. In the pre-chemotherapeutic patients, early and delayed ratios for the CR and PR groups were significantly higher than those for the NC group. There were no significant differences in the retention index with respect to the tumor response. 99m Tc-MIBI might be useful for evaluating the tumor chemosensitivity in patients with small cell lung cancer. (author)

  5. Prediction of functional recovery after revascularization using quantitative gated myocardial perfusion SPECT: a multi-center cohort study in Japan

    International Nuclear Information System (INIS)

    Nakajima, Kenichi; Tamaki, Nagara; Kuwabara, Yoichi; Kawano, Masaya; Matsunari, Ichiro; Taki, Junichi; Nishimura, Shigeyuki; Yamashina, Akira; Ishida, Yoshio; Tomoike, Hitonobu

    2008-01-01

    Prediction of left ventricular functional recovery is important after myocardial infarction. The impact of quantitative perfusion and motion analyses with gated single-photon emission computed tomography (SPECT) on predictive ability has not been clearly defined in multi-center studies. A total of 252 patients with recent myocardial infarction (n = 74) and old myocardial infarction (n = 175) were registered from 25 institutions. All patients underwent resting gated SPECT using 99m Tc-hexakis-2-methoxy-isobutyl isonitrile (MIBI) and repeated the study after revascularization after an average follow-up period of 132 ± 81 days. Visual and quantitative assessment of perfusion and wall motion were performed in 5,040 segments. Non-gated segmental percent uptake and end-systolic (ES) percent uptake were good predictors of wall motion recovery and significantly differed between improved and non-improved groups (66 ± 17% and 55 ± 18%, p 99m Tc-MIBI uptake provided a useful predictor of wall motion improvement. Application of quantitative approach with non-gated and ES percent uptake enhanced predictive accuracy over visual analysis particularly in a multi-center study. (orig.)

  6. The evaluation of dobutamine 99mTc-MIBI myocardial perfusion imaging in the diagnosis of coronary heart disease

    International Nuclear Information System (INIS)

    He Qing; Qu Wanying; Gong Junhui; Zhou Ying

    1996-01-01

    The method and the clinical value of dobutamine stress test as a substitute for exercise test in 99m Tc-MIBI myocardial perfusion imaging was investigated. 40 Patients were intravenously infused with dobutamine through IVAC syringe pumps by incremental doses, and 99m Tc-MIBI was injected at the peak dobutamine heart rate. The myocardial imaging was then performed. The rest myocardial imaging was done after 48 hours. 30 of the 31 patients with coronary heart disease showed reversible perfusion defects in dobutamine 99m Tc-MIBI myocardial perfusion images and 7 of the 9 patients without coronary heart disease showed normal images. The sensitivity of this test was 96.8% and the specificity 77.8%. None of the studies was discontinued due to dobutamine side effect. Dobutamine 99m Tc-MIBI myocardial perfusion imaging is a safe and sensitive method in the diagnosis of coronary heart disease

  7. Localizing diagnosis of hyperfunctional parathyroid glands using 99mTc-methoxyisobutylisonitrile (MIBI)

    International Nuclear Information System (INIS)

    Katagiri, Makoto; Yokobayashi, Tsuneo; Fukunaga, Masao; Harada, Tanekazu.

    1995-01-01

    In this study, we investigated the detectability of hyperfunctional parathyroid gland(s) by subtraction scintigraphy using 99m Tc-methoxyisobutylisonitrile and 99m Tc-pertechnetate (MIBI-Tc), and compared the findings with those obtained by conventional subtraction scintigraphy using 201 Tl-Cl and 99m Tc-pertechnetate (Tl-Tc), ultrasonography (US) and computed tomography (CT). The subjects were 6 patients with primary hyperparathyroidism (PHP) with a single adenoma and 13 with renal hyperparathyroidism (RHP) with hyperplasia receiving chronic maintenance hemodialysis. All of the patients underwent surgery, and the number and location of the abnormal parathyroid glands were confirmed. The numbers of resected parathyroid glands were 6 in the PHP group and 52 in the RHP group. In the PHP group, the detectability of hyperfunctional parathyroid glands with MIBI-Tc, Tl-Tc, US and CT was 83.3%, 100%, 83.3% and 83.3%, respectively. In the RHP group, on the other hand, these values were lower than those in the PHP group: 51.9%, 44.2%, 57.7% and 56.3%, respectively. No statistically significant differences were observed among the diagnostic tools in either group. As 99m Tc-MIBI has many physiological advantages over 201 Tl-Cl as a radiotracer, this radionuclide is expected to become useful for the detection of hyperfunctional parathyroid glands. (author)

  8. Gfr estimation using 99mTc DTPA gates method for assessment of early diabetic nephropathy - a comparison with 24-hour creatinine clearance

    International Nuclear Information System (INIS)

    Ghafoor, S.; Ali, M.K.; Khan, G.

    2014-01-01

    To correlate Gates glomerular filtration rate (GGFR) using technetium-99m diethylene triaminepentacetic acid (99mTc DTPA) with 24-hour creatinine clearance (CRCL) and to establish relationship with duration of diabetes in patients with early diabetic nephropathy. Study Design: A cross-sectional comparative study carried out in Nuclear Medical Centre from Aug 2009 to Jan 2010 at Armed Forces Institute of Pathology (AFIP), Rawalpindi, Pakistan. Patients and Methods: A total of eighty three subjects were enrolled, who were divided into three groups; group 1 comprised 31 normotensive diabetics, group 2 had 37 hypertensive diabetics while group 3 had 15 normal subjects. The DTPA GFR and creatinine clearance in healthy subjects as well as diabetic patients were compared using the unpaired student's t-test. The linear association between GFR, creatinine clearance and disease duration was expressed by Pearson's correlation coefficient 'r' along with their significance levels. Results: Gates GFR showed hyperfiltration in normotensive diabetics (96.6 +- 3.3 ml/min/1.73 m/sub 2/), significantly (p<0.05) higher than controls (85.5 +- 5 ml/min/1.73 m/sub 2/), whereas hypertensive diabetics had a significantly lower (p<0.05) Gates GFR (76.8 +- 3.7) than that of controls. Significant degree of correlation existed between GGFR and CRCL in hypertensive diabetics (p<0.05, r=0.716) and controls (r=0.546). Gates GFR also showed good correlation with duration of diabetes in both diabetic groups as compared to that of CRCL. GGFR also correlated well with duration of hypertension 0.37 (0.31-0.43) as compared to CRCL 0.155 (0.15-0.16) in all groups. Conclusions: The 99mTc-DTPA clearance correlates significantly with 24-hour creatinine clearance as well as with disease duration and can provide a simple and convenient index of kidney function in patients of early diabetic nephropathy. (author)

  9. Role of scintigammagraphy with 99mTc-Gluthatione and 99mTc-MIBI in the evaluation and staging of lymphoma

    International Nuclear Information System (INIS)

    Pena Quian, Yamile; Perera Pintado, Alejandro; Coca Perez, Marco A.; Batista Cuellar, Juan F.; Prats Capote, Anais; Sanchez Mendoza, Elvia; Sosa, Adriana; Mesa Cuervo, Jose R.; Hernandez Ramirez, Porfirio

    2004-01-01

    Full text: The aim of this study was to assess the utility of scintigammagraphy using 99mTc-MIBI and 99mTc-Gluthatione for the evaluation and staging of patients with lymphomas. We studied thirty patients (age range 16-66 years) of Hodgkin's disease (HD) and non-Hodgkin's lymphoma (NHL). A control group (CG) of 8 patients with negative histological results was also studied. The patients were divided in three groups; HD group: thirteen patients (7 males and 6 females); NHL: seventeen patients (10 males and 7 females); CG: eight patients (2 males and 6 females). Scintigammagraphy studies were performed 20 min and 2 h after intravenous administration of 925-1110 MBq of 99mTc-MIBI or 99mTc-Gluthatione (GSH) using a gamma camera (Sophy DS-7, Sopha Medical System, France) equipped with low energy all purpose parallel hole collimator. Anterior and posterior images of thorax, abdomen and pelvis in 128x128 pixels matrix each for 1 million counts per view were acquired. A 20% window centered on the 140 keV was used for all acquisitions. All images were processed and analysed on a workstation (Power Vision, SMV, Canada) and interpreted by three qualified and experienced nuclear medicine specialist. The final diagnosis was reached by consensus. The images with a focal abnormal intense uptake were considered positive. Images showing diffuse bilateral and symmetrical uptake, bilateral lung uptake and intestinal uptake were considered negative. The overall sensitivity, specificity and accuracy of results for both radiopharmaceuticals were calculated using the histological findings, x-ray, ultrasound and CT scanning as confirmation criterion as gold standard. The nodular sclerosis was the most frequent type in HD group. In this group twelve patients were positive with 99mTc-MIBI scintigammagraphy while one was negative (nodular sclerosis, grade II). Scintigammagraphy with 99mTc-GSH was positive in all patients in HD group. However, scintigammagraphy with both radiopharmaceuticals

  10. The clinical value of 99mTc-MIBI imaging for axillary lymph node metastasis of breast cancer

    International Nuclear Information System (INIS)

    Song Bangkun; Yang Jisheng; Shen Dawei; Zuo Lei; Jiang Ling; Zhou Ya

    2001-01-01

    Objective: To observe the clinical value of 99m Tc-MIBI imaging for axillary lymph node metastasis of breast cancer. Methods: 56 patients with breast cancer proven by pathology were imaged with 99m Tc-MIBI. Images were taken at 5, 30, 60 minutes. The axillary area of affected side was included in imaging field. Results: The primary foci in 55 cases were positive and one case was negative in uptake. Of the 56 cases, 35 had histologically proven axillary lymph node metastases. MIBI uptake was seen in 30 cases and negative in 5 cases. The sensitivity was 85.7% (30/35 cases). In 21 cases who had no metastasis, 3 cases showed false positive uptake and 18 cases were true negative, making the specificity 85.7%. In the case who had negative imaging for primary focus, which was non-palpable, had an enlarged axillary lymphatic node. Positive MIBI uptake of the node area was seen in this case. Conclusion: 99m Tc-MIBI imaging is valuable for the diagnosis of axillary nodal metastasis of breast cancer. Even though there is no palpable primary focus, if there is an enlarged axillary lymphatic node and positive MIBI uptake, metastasis should be considered

  11. Study of the elution {sup 99}Mo-{sup 99m}Tc generators produced at IPEN-CNEN/SP

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Paula Regina Corain [Pontificia Univ. Catolica de Sao Paulo, SP (Brazil); Instituto de Pesquisas Energeticas e Nucleares IPEN/CNEN-SP, Sao Paulo, SP (Brazil)]. E-mail: corain.lopes@uol.com.br; Osso Junior, Joao Alberto [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mail: jaosso@ipen.br

    2007-07-01

    Over the last years {sup 99m}Tc has become a very important asset in modern nuclear medicine, due to the emission of gamma ray of optimal energy (140 keV) and a suitable half-life (6.04 h). A further attribute of {sup 99m}Tc is its formation from the decay of {sup 99}Mo and the availability from {sup 99}Mo-{sup 99m}Tc generator systems. The most common and practical generator types consist of a chromatographic column packed with aluminium oxide, onto which the highly purified fission product {sup 99}Mo (imported from Canada) is adsorbed in the form of molybdate. {sup 99m}Tc is further eluted with saline solution. The objective of this work is to study the performance and the elution profile of {sup 99m}Tc from high activity generators in order to decrease molybdenum and aluminium concentration. The experiments involved the use of paper filters and Sep Pak columns and also the changing in the time interval between elutions. {sup 99}Mo breakthrough was measured using a dose calibrator and aluminium by UV-Vis spectrophotometry. The best results were achieved using a Sep Pak column containing neutral aluminium oxide. (author)

  12. Observation of 99Tcm-MIBI uptake of ischemic myocardium in dog models after left circumflex coronary artery constriction

    International Nuclear Information System (INIS)

    Cheng Guanghua; Dai Yunhai; Wu Kefang; Xu Quanfeng

    2008-01-01

    Objective: To observe 99 Tc m -MIBI uptake of ischemic myocardium at different times (1h, 4h) in dog models after left circumflex coronary artery constriction. Methods: 12 dog models of coronary artery stenosis were prepared by left circumflex coronary ligation, and were given injection of 99 Tc m -MIBI at the dosage of 185 MBq (5 mCi). Six models were sacrificed at one hour and four hours after the injection respectively. Radio-uptake in about 100 mg myocardium from both ischemic and non-ischemic sites were measured with r-counter. Results: No significant differences were found between ratios of radioactive count of ischemic over normal myocardial tissues at 1h and 4h after injection of 99 Tc m -MIBI (0.726±0.054 and 0.673±0.080, respective, t=1.3452, P >0.05). Conclusion: The extension of post-injection time would not increase 99 Tc m -MIBI uptake in ischemic myocardium. (authors)

  13. Myocardial perfusion scintigraphy with technetium99m-MIBI in the diagnosis of coronary artery disease in women

    International Nuclear Information System (INIS)

    Peix, A.T.; Chacon, D.; Ponce, F.; Torres, M.; Llerena, L.; Lopez, A.; Cabrera, O.; Maltas, A.M.; Carrillo, R.

    2002-01-01

    Aim: To assess the value of myocardial perfusion scintigraphy for coronary artery disease (CAD) in women, we compared the results of a technetium99m-methoxy-isobutyl-isonitrile ( 99m Tc-MIBI) scintigraphy with those of a coronary angiography in a group of women referred for evaluation of chest pain. Material and Methods: Twenty women, 15 of them postmenopausal, were included. A 99m Tc-MIBI myocardial scintigraphy with one-day protocol (rest-stress) was performed. When needed, a combined stress (ergometric plus dipyridamole) was used. Both qualitative and quantitative regional uptake analysis was done. In patients with normal coronary arteries and positive myocardial scintigraphies, measurements were made of serum cholesterol and triglycerides (CHOD-PAD enzymatic colorimetric test), and lipoprotein(a) -Lp(a)- (BioSCREEN Lp(a) method). Results: Change in regional uptake (stress/rest) was as follows: during stress 99m Tc-MIBI, 116 segments had normal uptake (from 93±9% to 94±7%), 52 had moderately reduced uptake (from 67±9% to 75±17%), and 12 had severely reduced uptake (from 33±9% to 64±28%). Qualitative and quantitative analysis coincided in 18 cases. The two non-coincident cases were patients in whom qualitative analysis and coronary angiography were normal, but on quantitative analysis it appeared a reversible defect in one case and a 'reverse redistribution' pattern in the other. Breast attenuation defects were detected in four cases. Myocardial scintigraphy and coronary angiography coincided in 70% cases (figure). The remainder 30% was constituted by patients with positive scintigraphy and normal coronary arteries; among these cases, the 71% were postmenopausal and had systolic hypertension, chest pain at rest, positive ergometric test and hypercholesterolemia (table). Conclusion: We concluded that 99m Tc-MIBI myocardial scintigraphy can help in the CAD diagnosis in postmenopausal women

  14. Is Tc99m-MIBI scintigraphy a predictor of response to pre-operative neoadjuvant chemotherapy in Osteosarcoma?

    Directory of Open Access Journals (Sweden)

    Vahidreza Dabbagh Kakhki

    2013-10-01

    Full Text Available Objectives: Multidrug resistance (MDR, which may be due to the over expression of P-glycoprotein (Pgp and/or MRP, is a major problem in neoadjuvant chemotherapy of osteosarcoma. The aim of this study was to investigate the role of Tc-99m MIBI scan for predicting the response to pre-operative chemotherapy. Materials and Methods: Twenty-five patients (12 males and 13 females, aged between 8 and 52y with osteosarcoma were studied. Before the chemotherapy, planar 99mTc-MIBI anterior and posterior images were obtained 10-min [tumor-to-background ratio: (T1/B110min] and 3-hr after tracer injection. After completion of chemotherapy, again 99mTc-MIBI scan was performed at 10-min after tracer injection. In addition to calculation of decay corrected tumor to background (T/B ratios ,  using the 10-min and 3-hr images of the pre-chemotherapy scintigraphy , percent wash-out rate (WR% of 99mTc-MIBI was calculated. Using the 10-min images of the pre- and post-chemotherapy scans, the percent reduction in uptake at the tumor site after treatment (Red% was also calculated. Then after surgical resection, tumor response was assessed by percentage of necrosis. Results: All patients showed significant 99mTc-MIBI uptake in early images. Only 9 patients showed good response to chemotherapy (necrosis≥90% while 16 patients were considered as non-responder (necrosis

  15. Quantitative planar imaging with technetium-99m methoxyisobutyl isonitrile: Comparison of uptake patterns with thallium-201

    International Nuclear Information System (INIS)

    Sinusas, A.J.; Beller, G.A.; Smith, W.H.; Vinson, E.L.; Brookeman, V.; Watson, D.D.

    1989-01-01

    To compare the myocardial uptake pattern of 99mTc-labeled methoxyisobutyl isonitrile [( 99mTc] MIBI) and 201TI, planar scintigraphy were performed in both patients with documented coronary artery disease and subjects with a low likelihood of disease. Quantitative analysis was employed using a standard interpolative background subtraction algorithm and a new algorithm modified to better accommodate for the differences in extracardiac activity seen with [99mTc]MIBI rest images. Among patients with coronary artery disease, the standard algorithm yielded no significant difference in relative defect magnitude between [99mTc]MIBI and 201TI on stress scintigrams (p = 0.48), although the magnitude of [99mTc]MIBI defects was greater on resting images (p = 0.02). When the modified algorithm was employed, defect magnitude was similar for both stress (p = 0.91) and rest (p = 0.20) images. Normal segmental uptake ratios derived from a comparison of contralateral segments (e.g., septal:posterolateral) in the low likelihood patients were similar for both [99mTc]MIBI and 201TI. Thus, modification of the standard interpolative background subtraction algorithm is necessary for quantitative planar [99mTc]MIBI perfusion imaging. When appropriate background subtraction is employed, myocardial uptake and quantitative defect magnitude of [99mTc]MIBI and 201TI planar images are similar

  16. Limitations of Tc99m-MIBI-SPECT imaging scans in persistent primary hyperparathyroidism

    NARCIS (Netherlands)

    Witteveen, Janneke E.; Kievit, Job; Stokkel, Marcel P. M.; Morreau, Hans; Romijn, Johannes A.; Hamdy, Neveen A. T.

    2011-01-01

    In primary hyperparathyroidism (PHPT) the predictive value of technetium 99m sestamibi single emission computed tomography (Tc99m-MIBI-SPECT) for localizing pathological parathyroid glands before a first parathyroidectomy (PTx) is 83-100%. Data are scarce in patients undergoing reoperative

  17. Diagnostic value of early post-exercise 99Tcm-MIBI ECG-gated myocardial perfusion imaging in severe coronary artery disease

    International Nuclear Information System (INIS)

    Li Dianfu; Huang Jun; Feng Jianlin; Cheng Xu; Li Xinli; Cao Kejiang

    2005-01-01

    Objective: To study and compare the diagnostic value in severe coronary artery disease (CAD) of 99 Tc m -methoxyisobutylisonitrile (MIBI) electrocardiogram (ECG)-gated early post-exercise myocardial perfusion imaging (G-MPI) with that of non-ECG-gated myocardial perfusion imaging (NG-MPI). Methods: Two hundred and fifteen suspected CAD patients had undergone G-MPI and coronary artery angiography (CAG) within one month were enrolled and distributed into three-vessel and non-three-vessel CAD groups according to CAG results (≥70%); the diagnostic values in severe CAD of G-MPI and NG-MPI were gained and compared to determine which one of the two protocols would be superior in identification of severe three-vessel CAD. Results: When the ≥70% diameter stenosis CAG was the diagnostic standard of severe CAD, the sensitivity of G-MPI and NG-MPI in the diagnosis of severe CAD were 95.3% (143/150) and 90.7% (136/150, χ 2 =2.509, P=0.113), but when the comparison specifically pinpointed to severe three-vessel CAD, there was significant difference between G-MPI [100%(51/51)] and NG-MPI [92.2% (47/51), χ 2 =4.163, P=0.041]. Diagnostic specificity of G-MPI was 80.0% and that of NG-MPI was 72.3% (χ 2 =1.059, P=0.303). Conclusions: The incremental diagnostic sensitivity of G-MPI adding to the NG-MPI in the diagnosis of severe CAD was mainly from the three-vessel subgroup patients. Exercise stress G-MPI has better diagnostic value in severe three-vessel CAD patients than NG-MPI. (authors)

  18. Comparative study of {sup 99}Mo/{sup 99m}Tc generators at base of synthesized gels starting from activation and fission {sup 99}Mo; Estudio comparativo de generadores {sup 99}Mo/{sup 99m}Tc a base de geles sintetizados a partir de {sup 99}Mo de activacion y de fision

    Energy Technology Data Exchange (ETDEWEB)

    Lopez M, I Z [UAEM, Paseo Colon esq. Paseo Tollocan, 50120 Toluca, Estado de Mexico (Mexico); Monroy G, F; Rivero G, T; Rojas N, P [ININ, Carretera Mexico -Toluca S/N, 52045 La Marquesa Ocoyoacac, Estado de Mexico (Mexico)

    2007-07-01

    The {sup 99m}Tc is used for diagnostic and therapy. It is produced starting from {sup 99}Mo, absorbed in chromatographic columns, loaded with alumina that absorb only 0.2% of {sup 99}Mo with high specific activities of {sup 99}Mo, obtained from the {sup 235}U fission. Given these conditions and limitations, new preparation procedures of {sup 99}Mo/{sup 99m}Tc generators, its have been developed, using zirconium molybdates gels that incorporates until 30% of {sup 99}Mo, conserve similar characteristics of quality and purity that the traditional generator. The radiochemical characteristics of the {sup 99m}Tc elution, depend strongly on the gel preparation conditions. In particular, the present work has by object to determine the influence of the {sup 99}Mo used type, fission or activation product, during the gels synthesis, as well as the used air flow for the agitation in the gels preparation and its influence in the {sup 99}Mo/{sup 99m}Tc generators quality. When diminishing the flow of agitation air the efficiency it increases and in the radionuclide purity of the eluates and when using {sup 99}Mo from fission for the gels production it increases in an important way the elutriation efficiency, the radiochemical and radionuclide purity of the {sup 99m}Tc eluates. (Author)

  19. A study of microscopic dose rate distribution of 99Tcm-MIBI in the liver of mice

    International Nuclear Information System (INIS)

    Wang Mingxi; Zhang Liang'an; Wang Yong; Dai Guangfu

    2002-01-01

    Objective: A microdosimetry model was tried to develop an accurate way to evaluate absorbed dose rates in target cell nuclei from radiopharmaceuticals. Methods: Microscopic frozen section autoradiography was used to determine the subcellular locations of 99 Tc m -MIBI relative to the tissue histology in the liver of mice after injection of 99 Tc m -MIBI via tail for two hours, and a mathematical model was developed to evaluate the microscopic dose rates in cell nuclei. The Medical Internal Radiation Dose (MIRD) schema was also used to evaluate the dose rates at the same time, and a comparison of the results of the two methods was conducted to determine which method is better to accurately estimate microscopic dose rates. Results: The spatial distribution of 99 Tc m -MIBI in the liver of mice at subcellular level was not uniform, and the differences between the microdosimetry model and MIRD schema were significant (P 99 Tc m -labeled pharmaceuticals at the microscopic level

  20. Diagnostic accuracy of Tc-99m MIBI scintimammography in breast cancer

    International Nuclear Information System (INIS)

    Park, Jung Mi; Choi, Joon Young; Lee, Kyung Han; Kim, Sang Eun; Kim, Byung Tae; Nam, Suk Jin; Yang, Jung Hyun

    1998-01-01

    For the characterization of breast mass, the results of Tc-99m MIBI scintimmamography were much varied between studies. This may result from various factors including tumor size, experience of observer and expression of MDR gene, So, we evaluated the influence of tumor size, knowledge of clinical information, experience of observer and expression of Pgp53 gene on the accuracy of MIBI scintimmamography for the characterization of breast mass. MIBI scintimmamography was prospectively performed in 44 patients with breast masses before surgical resection. The anterior and both lateral prone chest images were acquired at 5 min and 3 hour after injection of 740 MBq of Tc-99m MIBI. Two independent observers reviewed the images for characterization of breast mass without any clinical information. Then the images were reviewed with knowledge of clinical information including tumor size and location. If lesions proved to be malignant, presence of Pgp53 was evaluated by immunohistochemical staining. The comparisons of intraobserver/interobserver diagnostic accuracy and variance were performed by chi-square test and kappa test, respectively. The 54.4% of all lesions (24/44) were malignant. The sensitive, specificity and accuracy of scintimmamography were 73.3%, 82.8%, 79.5% and 73.3%, 84.5%, 80.7% with/without clinical information in observer A, and 76.7%, 86.2%, 83% and 70%, 89.7%, 83% with/without clinical information in observer B, respectively. There were no significant differences in sensitivity, specificity and accuracy between two observers or in same observer with/without clinical information. The agreement for the characterization of breast mass between the two observers was significantly excellent (κ=0.876/ κ=0.897 with/without clinical information, respectively). Intraobserver variance according to the knowledge of clinical information was also small ( κ=0.795 in observer A; κ=0.900 in observer B). Pgp53 was positive in 8 lesions. The sensitivities of

  1. Feasibility of fractionating MIBI cold kits for cost reduction

    Energy Technology Data Exchange (ETDEWEB)

    Penglis, S.; Tsopelas, C. [Royal Adelaide Hospital. SA (Australia)

    1998-06-01

    Full text: Recently {sup 99m}Tc-MIBI become the first 99mTc-labelled myocardial perfusion imaging agent commercially available in Australia. After labelling each vial is sufficient for three to four patient doses. However, it becomes very expensive when only a single patient dose is required (up to $350 per dose). Our goal in this study was to subdivide the MIBI kit into fractions to establish the stability of these split kits. If successful, this would reduce the expense and make the product more cost-effective. After dissolving the Iyophilised ingredients of a MIBI vial with 5 mL of N2-purged normal saline, 1 mL aliquots of the resultant solution were dispensed into N2-filled vials under aseptic conditions. The vials were then stored frozen at -70 deg C. 99mTc-MIBI was prepared by the addition of 2 GBq of {sup 99m}Tc-pertechnetate in I mL of normal saline to the fractionated kit, followed by heating at 100 deg C for 10 minutes at 0, 2, 4 and 8 weeks post-fractionation. The product was allowed to cool before testing for radiochemical purity (RCP) for up to six hours post-labelling. The RCP of each vial was determined using aluminium oxide coated aluminium TLC strips (Merck) run in 100% ethanol. Over the eight-week evaluation period RCP was maintained at 94.2 + 1.3% over six hours (n = 16), which is greater than the minimum recommended RCP (90%) for patient use. These results show that fractionation of MIBI cold kits and sub-frozen storage under an N{sub 2} atmosphere provides a stable and economical multidose product. Using this method the cost of a single patient dose can be reduced considerably from $350, even allowing for the labour involved in the fractionation

  2. Feasibility of fractionating MIBI cold kits for cost reduction

    International Nuclear Information System (INIS)

    Penglis, S.; Tsopelas, C.

    1998-01-01

    Full text: Recently 99m Tc-MIBI become the first 99mTc-labelled myocardial perfusion imaging agent commercially available in Australia. After labelling each vial is sufficient for three to four patient doses. However, it becomes very expensive when only a single patient dose is required (up to $350 per dose). Our goal in this study was to subdivide the MIBI kit into fractions to establish the stability of these split kits. If successful, this would reduce the expense and make the product more cost-effective. After dissolving the Iyophilised ingredients of a MIBI vial with 5 mL of N2-purged normal saline, 1 mL aliquots of the resultant solution were dispensed into N2-filled vials under aseptic conditions. The vials were then stored frozen at -70 deg C. 99mTc-MIBI was prepared by the addition of 2 GBq of 99m Tc-pertechnetate in I mL of normal saline to the fractionated kit, followed by heating at 100 deg C for 10 minutes at 0, 2, 4 and 8 weeks post-fractionation. The product was allowed to cool before testing for radiochemical purity (RCP) for up to six hours post-labelling. The RCP of each vial was determined using aluminium oxide coated aluminium TLC strips (Merck) run in 100% ethanol. Over the eight-week evaluation period RCP was maintained at 94.2 + 1.3% over six hours (n = 16), which is greater than the minimum recommended RCP (90%) for patient use. These results show that fractionation of MIBI cold kits and sub-frozen storage under an N 2 atmosphere provides a stable and economical multidose product. Using this method the cost of a single patient dose can be reduced considerably from $350, even allowing for the labour involved in the fractionation

  3. Role of adenosine 99MTc sestamibi myocardial perfusion spect in evaluation of symptomatic hypertensives with recent onset left bundle branch block

    International Nuclear Information System (INIS)

    Padma, S.; Sundaram, P.S.; Zachariah, M.; Hariads, K.K.

    2004-01-01

    Objectives: Adenosine pharmacological stress Myocardial Perfusion Imaging (AMPI) is the preferred imaging modality for IHD evaluation in pts with Left Bundle Branch Block (LBBB). Good prognosis has been reported in recent onset LBBB pts with normal MPI. Our aim was to evaluate the utility and analyze the predictive value of SestaMIBI AMPI in symptomatic recent onset LBBB hypertensives for coronary artery disease evaluation. Methods: 29 hypertensive pts, age range 36-72yrs, mean 54+ 6 yrs, M:F- 21:8 with recent onset complete LBBB, under evaluation for typical/atypical angina who had AMPI between Nov 02-Nov 03, were retrospectively analyzed. LBBB was diagnosed ECG wise if there is prolonged QRS complex i.e. 0.125sec or more in sinus/supraventricular rhythm, a QS or rS complex in lead 1, and an R-wave peak time of 0.06sec in leads 1, V5 or V6 with no Q wave in same lead. Pts with prior Myocardial Infarct / revasularisation, pacemaker induced LBBB were excluded. Single day 6 min. Adenosine infusion Stress-rest 99m Tc MIBI gated MPI was performed with a dual head variable angle Gamma Camera at 76-degree angle. Coronary Angiogram (CAG) correlation was available in 24 pts. Results: Myocardial perfusion SPECT images were assessed visually and by a 20-segment model. Location, extent and severity of the LV perfusion defects were evaluated. 6/29 pts (20.7%) had normal stress-rest perfusion in all LV segments.12 (41.4%) had isolated septal fixed defect with normal perfusion in rest of the segments.3 pts (10.3%)showed isolated reversible septal defects while 8(27.6%) had reversible septal defects with reversible defects in other LV segments also. Pts with fixed septal perfusion defect showed moderate to good septal wall thickening in gated SPECT images. While all pts with multiple reversible perfusion defects had angiographically proven coronary artery disease (i.e. 3pts had LAD lesion, 2 had Triple vessel and 3 showed double vessel lesions), 1 out of 3 pts with isolated

  4. Evaluation of effects of early intravenous thrombolytic therapy in acute myocardial infarction with 99mTc-MIBI tomography imaging

    International Nuclear Information System (INIS)

    Zhang Zhongzheng; Xue Zheng; Qin Fuzhong

    1997-01-01

    PURPOSE: To evaluate the effects of early intravenous thrombolytic therapy in acute myocardial infarction (AMI) with 99m Tc-MIBI tomography imaging. METHODS: 22 patients with AMI were observed using 99m Tc-MIBI rest myocardial tomography imaging. The semiquantitative score of myocardial 99m Tc-MIBI uptake was expressed with a four point scoring system. RESULTS: The findings showed in patients in whom reperfusion was achieved, mean scores decreased from 9.1 +- 3.3 before thrombolytic therapy to 3.7 +- 2.2 (t 4.085, P 99m Tc-MIBI perfusion defect segments correlated with that of the ECG-determined infarct site. The comparison between the first and the second myocardial imaging in the non-thrombolytic-treatment group was statistically insignificant. CONCLUSION: The potential advantages of rest myocardial imaging in AMI before and after thrombolytic therapy not only provide an information for assessing the extent of improvement of myocardial ischemia but also provide an imaging basis for determining coronary artery reperfusion

  5. Preperation and performance of {sup 99}Mo/{sup 99m}Tc chromatographic column generator based on zirconium molybdosilicate

    Energy Technology Data Exchange (ETDEWEB)

    Mostafa, M.; Saber, H.M.; El-Sadek, A.A. [Atomic Energy Authority, Cairo (Egypt). Hot Labs. Center; Nassar, M.Y. [Benha Univ. (Egypt). Chemistry Dept.

    2016-08-01

    Zirconium molybdosilicate (ZrMoSi) gel prepared using {sup 99}Mo radiotracer via peroxo route was used as a base material for {sup 99}Mo/{sup 99m}Tc column generator. The {sup 99m}Tc elution yield and {sup 99}Mo breakthrough in the eluate were studied as a function of the pH-value of gel precipitation, gel drying temperature and Zr: Mo: Si molar ratio. Precipitation pH-value of 2, drying temperature of 100 C and Zr: Mo: Si molar ratio of 0.5: 0.5: 1 were found to be the optimum conditions achieving {sup 99m}Tc elution yield of 82% and {sup 99}Mo breakthrough of 1.0 x 10{sup -3}%. The gel prepared with the optimum conditions was characterized by BET surface area and pore size analyzer, IR spectroscopy, thermal analysis (TGA and DTA), XRD, XRF and FESEM. Technetium-99m eluted from the optimum ZrMoSi {sup 99}Mo/{sup 99m}Tc generator was found to have a high radiochemical purity (98% as {sup 99m}TcO{sub 4}{sup -}) and chemical purity meeting criteria of clinical grade.

  6. Comparison of Nitrate-augmented resting gated 99mTc-Sestamibi imaging with Low Dose Dobutamine SPECT for the detection of Myocardial Viability

    International Nuclear Information System (INIS)

    Parameswaran, R.V.; Dash, P.K.; Barooah, B.; Guruprasad, H.P.; Purantharan, N.

    2002-01-01

    Background: Dobutamine Echocardiography and Radionuclide imaging with Tl-201 and Technetium agents are two of the most established techniques available for the detection of viable myocardium. The purpose of this study was to evaluate the utility of Low dose Dobutamine gated Myocardial SPECT in identifying additional areas of dysfunctional, but viable myocardium when compared to nitrate-augmented rest gated SPECT with SestaMIBI. Materials and Methods: 20 patients (19 males and 1 female, with an age range of 40- 65 yrs and a mean of 52.75yrs) all with history of MI or severe LV dysfunction were included in this study. Patients with LBBB, recent revascularisation, arrhythmias etc were excluded from the study. A routine stress-rest study was initially performed on them with 99mTc-SestaMIBI and both the stress as well as resting studies was gated and the resting study was augmented with 10mg of sublingual nitrate. After the resting study was over, the patient was infused with Low dose Dobutamine(5μg/kg/min), at which time the gated acquisition was started and the infusion was continued till the acquisition got completed. In the perfusion study with SestaMIBI, all infarct segments which have uptake less than 50% as compared to the maximally perfused area was deemed non-viable Results: A 17-segment Myocardial model was used for both perfusion as well as quantification of wall motion and wall thickening. 110 akinetic/dyskinetic segments were taken up for analysis. 93 of these segments were non-viable and improvement in wall motion was seen in 17 segments (15.4%) in the nitrate-augmented SPECT. Dobutamine study showed improvement in totally in 27 segments (24.5%), 10 of which were additional segments which were non-viable in Nitrate SPECT study, apart from the 17 segments which showed improvement in the Nitrate study. In Dobutamine study, there was also improvement in wall thickening in 10 (10.7%) out of 93 segments which had showed less than 50% of MIBI uptake. Conclusion

  7. A comparison of radionuclide thyroid angiography, 99mTc-MIBI scintigraphy and power Doppler ultrasonography in the differential diagnosis of solitary cold thyroid nodules

    International Nuclear Information System (INIS)

    Demirel, Koray; Kapucu, Oezlem; Yuecel, Cem; Oezdemir, Hakan; Ayvaz, Goeksun; Taneri, Ferit

    2003-01-01

    We prospectively studied 43 patients with solitary cold thyroid nodules greater than 1.5 cm in diameter to determine the comparative diagnostic value of radionuclide thyroid angiography (RTA), technetium-99m methoxyisobutylisonitrile ( 99m Tc-MIBI) scintigraphy and power Doppler ultrasonography (PDUS) in the differentiation of benign and malignant thyroid nodules. Perfusion of the nodules in RTA was compared with the perfusion in the surrounding normal thyroid tissue and classified as follows: 0, avascular; 1, hypovascular; 2, isovascular; 3, hypervascular. 99m Tc-MIBI uptake in the nodules compared with that in surrounding thyroid tissue was scored for both early and delayed images as follows: 0, cold; 1, decreased; 2, equal; 3, increased. PDUS patterns were classified as nodule vascularisation patterns. The malignancy criteria were set as follows: hypervascular nodule with rapid washout in RTA; complex ring sign with anarchic structure or delta sign in PDUS, and positive retention and increased uptake in the nodule in the early and delayed 99m Tc-MIBI images. These data were compared with the histopathological results. Histology revealed thyroid carcinoma in nine patients (five cases of papillary carcinoma, three of follicular carcinoma and one of medullary carcinoma) and benign conditions in 34 patients (30 cases of nodular goitre, three of lymphocytic thyroiditis and one of follicular adenoma). Sensitivity, specificity and accuracy were, respectively, 0.89, 1.00 and 0.97 for RTA, 1.00, 0.76 and 0.81 for PDUS, and 0.67, 0.91 and 0.86 for 99m Tc-MIBI scintigraphy (when nodules with increased uptake in both the early and the delayed images and a positive retention index were considered as malignant). RTA, 99m Tc-MIBI scintigraphy and PDUS could be helpful in the preoperative assessment of solitary cold thyroid nodules. In this study, RTA was found to be the most accurate and specific method for differentiation of malignant from benign thyroid nodules. (orig.)

  8. Comparison of the uptakes of Tc-99m MIBI and Tc-99m tetrofosmin in A549, an MRP-expressing cancer cell, in vitro and in vivo

    International Nuclear Information System (INIS)

    Yoo, Jeong Ah; Jeong, Shin Young; Seo, Myung Rang; Bae, Jin Ho; Ahn, Byeong Cheol; Lee, Kyu Bo; Lee, Jae Tae; Choi, Sang Woon; Lee, Byung Ho

    2003-01-01

    Uptakes of Tc-99m MIBI (MIBI) and Tc-99m tetrofosmin (tetrofosmin) in human non-small cell lung cancer A549, multidrug-resistance associated protein (MRP) expressing cell, were investigated in vitro and in vivo. Western blot analysis and immunohistochemistry were used for detetion of MRP in A549 cells with anti-MRPr1 antibody. Cellular uptakes of two tracers were evaluated at 100 μM of verapamil (Vrp), 50 μM of cyclosporin A (CsA) and 25 μM of butoxysulfoximide (BSO) after incubation with MIBI and tetrofosmin for 30 and 60 min at 37.deg.C, using single cell suspensions at 1x10 6 cells/ml. Radioactivities in supernatants and pellets were measured with gamma well counter. A549 cells were inoculated in each flanks of 24 nude mice. Group 1 (Gr1) and Gr3 mice were treated with only MIBI or tetrofosmin, and Gr2 and Gr4 mice were treated with 70mg/kg of CsA i.p. for 1 hour before injection of 370KBq of MIBI or tetrofosmin. Mice were sacrificed at 10, 60 and 240 min. Radioactivities of organs and tumors were expressed as percentage injected dose per gram of tissue (%ID/gm). Western blot analysis of the A549 cells detected expression of MRPr1 (190 kDa) and immunohistochemical staining of tumor tissue for MRPr1 revealed brownish staining in cell membrane but not P-gp. Upon incubating A549 cells for 60 min with MIBI and tetrofosmin, cellular uptake of MIBI was higher than that of tetrofosmin. Coincubation with modulators resulted in an increase in cellular uptakes of MIBI and tetrofosmin. Coincubation with modulators resulted in an increase in cellular uptakes of MIBI and tetorfosmin. Percentage increase of MIBI was higher than that of tetrofosmin with Vrp by 623% and 427%, CsA by 753% and 629% and BSO by 219% and 140%, respectively. There was no significant difference in tumoral uptakes of MIBI and tetrofosmin between Gr1 and Gr3. Percentage increases in MIBI (114% at 10 min, 257% at 60 min, 396% at 240 min) and tetrofosmin uptake (110% at 10 min, 205% at 60 min, 410% at

  9. Actions needed to ensure a reliable supply of 99Mo and 99mTc?

    International Nuclear Information System (INIS)

    Cameron, R.; Peykov, P.

    2014-01-01

    The NEA established the High-level Group on the Security of Supply of Medical Radioisotopes (HLG-MR) to examine the causes of 99 Mo/ 99 mTc supply shortages in 2009. It undertook an economic analysis and determined that lack of economic sustainability in producing reactors was the major cause of the shortages. From that it developed a policy approach, including principles and supporting recommendations to address those causes. Since then it has looked at the way the supply chain has implemented these policy principles through initiating a self-assessment process, which revealed uneven application and lack of adherence to the key principle of full cost recovery. As part of the analysis, the NEA has also reviewed the global 99 Mo/ 99 mTc supply situation periodically, using the most up-to-date data from supply chain participants, to highlight periods of reduced supply and underscore the case for implementing the HLG-MR policy approach in a timely and globally-consistent manner. This current paper presents the preliminary results from an updated 99 Mo supply and demand forecast, focusing on the potentially critical 2015-2020 period, when two major 99 Mo producers (the NRU reactor in Canada and the OSIRIS reactor in France) are scheduled to cease 99 Mo irradiations. It concludes with a review of the effectiveness of the actions taken to date and indicates where further action is needed. (author)

  10. Impact of Gate 99mTc DTPA GFR, Serum Creatinine and Urea in Diagnosis of Patients with Chronic Kidney Failure

    Science.gov (United States)

    Miftari, Rame; Nura, Adem; Topçiu-Shufta, Valdete; Miftari, Valon; Murseli, Arbenita; Haxhibeqiri, Valdete

    2017-01-01

    Aim: The aim of this study was determination of validity of 99mTcDTPA estimation of GFR for early detection of chronic kidney failure Material and methods: There were 110 patients (54 males and 56 females) with kidney disease referred for evaluation of renal function at UCC of Kosovo. All patients were included in two groups. In the first group were included 30 patients confirmed with renal failure, whereas in the second group were included 80 patients with other renal disease. In study were included only patients with ready results of creatinine, urea and glucose in the blood serum. For estimation of GFR we have used the Gate GFR DTPA method. The statistical data processing was conducted using statistical methods such as arithmetic average, the student t-test, percentage or rate, sensitivity, specificity and accuracy of the test. Results: The average age of all patients was 36 years old. The average age of female was 37 whereas of male 35. Patients with renal failure was significantly older than patients with other renal disease (p<0.005). Renal failure was found in 30 patients (27.27%). The concentration of urea and creatinine in blood serum of patients with renal failure were significantly higher than in patients with other renal disease (P< 0.00001). GFR in patients with renal failure were significantly lower than in patients with other renal disease, 51.75 ml/min (p<0.00001). Sensitivity of uremia and creatininemia for detection of renal failure were 83.33%, whereas sensitivity of 99mTcDTPA GFR was 100%. Specificity of uraemia and creatininemia were 63% whereas specificity of 99mTcDTPA GFR was 47.5%. Diagnostic accuracy of blood urea and creatinine in detecting of renal failure were 69%, whereas diagnostic accuracy of 99mTcDTPA GFR was 61.8%. Conclusion: Gate 99mTc DTPA scintigraphy in collaboration with biochemical tests are very sensitive methods for early detection of patients with chronic renal failure. PMID:28883673

  11. Phenolic aminocarboxylate chelates of 99mTc as hepatobiliary agents.

    Science.gov (United States)

    Hunt, F C; Maddalena, D J; Wilson, J G; Bautovich, G J

    1986-01-01

    A series of alkyl- and halogen-substituted derivatives of ethylenediamine di[o-hydroxyphenylacetic acid] (EDDHA) and N,N'-bis[2-hydroxybenzyl] ethylenediamine N,N'-diacetic acid (HBED) were complexed with 99mTc and their biodistribution was determined in rats. All complexes displayed substantial hepatobiliary excretion; of each series, 99mTc-Br-EDDHA and 99mTc-di-Cl-HBED had the maximum amount in the gastrointestinal tract. Scintigraphic studies of 99mTc-Cl-EDDHA in dogs revealed prompt imaging of the liver followed by imaging of the gall bladder as the complex was excreted into the bile.

  12. Preparation of clinical-scale 99Mo/99mTc column generator using neutron activated low specific activity 99Mo and nanocrystalline γ-Al2O3 as column matrix.

    Science.gov (United States)

    Chakravarty, Rubel; Ram, Ramu; Dash, Ashutosh; Pillai, M R A

    2012-10-01

    Preparation of clinical-scale (99)Mo/(99m)Tc generator using (n,γ) activated low specific activity (99)Mo and nanocrystalline γ-Al(2)O(3) as a high capacity sorbent matrix is attempted. Nanocrystalline γ-Al(2)O(3) was synthesized by 'solid state mechanochemical' reaction of aluminum nitrate with ammonium bicarbonate. Experimental parameters were optimized to effectively separate (99m)Tc from (99)Mo using this sorbent as the column matrix. The performance features of a 13 GBq (350 mCi) (99)Mo/(99m)Tc generator using this sorbent and (99)Mo produced by (n,γ) route having specific activity 12.9-18.5 GBq/g were evaluated for 10 days. The sorbent possessed the requisite selectivity for (99)Mo and demonstrated a maximum sorption capacity of 200 ± 5mg Mo/g, which is ~10 times higher than that of ordinary acidic alumina. The overall yield of (99m)Tc was >80%, with radionuclidic purity >99.99% and radiochemical purity >99%. The yield of (99m)Tc varied from 7.8 to 2.1 GBq in the eluate for the six days of operation of the generator. The radioactive concentration of (99m)Tc eluted was adequate for the formulation of radiopharmaceuticals. The performance of the generator remained consistent over an extended period of 10 days. The eluted (99m)Tc was suitable for the formulation of (99m)Tc-DMSA and (99m)Tc-EC resulting in high radiolabeling yields (>98%). The effectiveness of γ-Al(2)O(3) as a new generation sorbent in the development of clinically useful (99)Mo/(99m)Tc generator using low specific activity (99)Mo and yielding (99m)Tc with adequate radioactive concentration and high purity suitable for formulation of radiopharmaceuticals is demonstrated. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Comparison of 99mTc-MIBI Myocardial Uptake at Rest with Reinjection and 24-hour after Reinjection Images of 201T1

    International Nuclear Information System (INIS)

    Bom, Hee Seung; Kim, Ji Yeul; Park, Joo Hyung; Ahn, Young Keun; Jeong, Myung Ho; Cho, Jeong Gwan; Park, Jong Choon; Kang, Jung Chaee

    1992-01-01

    Clinical role of 99m Tc-MIBI myocardial scintigraphy in the diagnosis of coronary artery disease (CAD) is now well accepted, however, the role of it in the identification of viable myocardium in patients with chronic CAD has not yet been clarified. To determine the usefulness of rest-injected 99m Tc-MIBI scan as a marker of myocardial viability, the regional uptake of this agent at rest was compared with that of '2 01 T1 on reinjection and 24 hours after reinjection images. Subject patients were 13 chronic CAD patients who showed irreversible perfusion defect(s) on standard pharmacologic (dipyridamole) stress-redistribution images. Immediately after the redistribution images were obtained, 37 MBq thallium was injected at rest, and images were reacquired at 10 minutes and 24 hours after reinjection. After then 740 MBq 99m Tc-MIBI was injected, and 1 hour later rest MIBI myocardial imaging was performed. Five sets of images (stress, redistribution, reinjection, delayed images of thallium, and rest image of MIBI) were then analyzed qualitatively and quantitatively. Left ventricle was arbitrarily divided into 9 segments (apex, basal and apical portions of anterior, septal, inferior, and lateral walls). Seven patients and 30 regions showed a fixed perfusion defect on the stress-redistribution images. Among 30 regions, 15 showed positive uptakes and 6 showed negative uptakes on both 201 T1 reinjection/delayed images and 99m Tc-MIBI rest images. Five regions showed only thallium uptake and were regarded as viable clinically. Of four regions which showed only 99m Tc-MIBI uptake, two were regarded as viable, while the other two were regarded as a nonviable scar tissue clinically. In conclusion, 201 T1 reinjection technique was more reliable in the identification of viable myocardium. However, the role of 99m Tc-MIBI in identification of viable myocardium was still remained to be clarified because 2 of 9 regions showed only 99m Tc-MIBI uptake and were regarded as viable

  14. Scintigraphy with Tc99m-MIBI to annual prediction the evolution of women referred for evaluation of precordial pain

    International Nuclear Information System (INIS)

    Peix, Amalia; Chacon, Deylis; Ponce, Felizardo; Lopez, Adlin; Cabrera, Omar; Maltas, Ana Ma.; Carrillo, Regla

    2002-01-01

    In order to evaluate the capacity of myocardial perfusion scintigraphy with Tc99m-MIBI to predict the evolution of women referred for evaluation of precordial pain, the rates of cardiovascular events at one year were studied in a group of patients with normal scintigraphy (group 1: 17 patients) and in another with reversible perfusion defects (group 2: 17 patients). The one-day protocol was applied for scintigraphy with Tc99m-MIBI (rest/stress) with combined stress (ergometrin bicycle plus 0.28 mg/Ig of dipyridamole) in those cases where it was necessary. A quantitative and qualitative analysis of the regional uptake was made. Patients from group 1 were younger than those from group 2 (average age: 49 vs 55, respectively, p = 0.04) and they had less hypercholesterolemia (112 % vs 59 %, respectively, p = 0.01). The rates of appearance of cardiovascular events at one year were calculated for patients from group 2 by using the Kaplan-Meier's method. The rates of appearance of clinical events (myocardial infarction and unstable angina) and of revascularization procedures (percutaneous transluminal coronary angioplasty and aortocoronary bypass surgery) were 0.24 in both cases. Only a patient from group 1 presented varying angina at 5 months. No deaths were reported in any of the groups. 94 % of the patients with normal perfusion scintigraphy were free of events after a one-year follow-up, whereas only 53 % of those with reversible perfusion defects showed a similar behavior. It was concluded that myocardial perfusion scintigraphy with Tc99m-MIBI is a useful tool to predict the evolution of women referred for evaluation of precordial pain at one year

  15. Pre-operative localization of parathyroid adenoma by Tc-99m-sestamibi scintigraphy (MIBI)

    International Nuclear Information System (INIS)

    Ramadan, Edward; Vishne, Tal H; Koren, Romelia; Lerner, Igor; Melloul, Moshe; Dreznik, Zeev

    2002-01-01

    The use of pre-operative imaging for localization of primary parathyroid adenoma may influence the duration and results of parathyroidectomy. The current study was aimed to evaluate the efficiency of localization of parathyroid adenoma by Tc-99m-sestamibi (MIBI) scintigraphy and compare the results with those achieved by the use of preoperative ultrasound. Seventy five patients, aged 25 to 83 years with primary hyperparathyroidism were operated due to primary adenoma in Rabin Medical Center from January 1995 to April 1997. Fifty of them had a preoperative MIBI scintigraphy and ultrasound for localization of parathyroid adenoma, while 25 had a preoperative ultrasound alone. Ultrasound identified correctly the adenoma in 84 percent of the cases, as compared to 96 percent identified by MIBI scintigraphy (p<0.01). MIBI scintigraphy shortened operation length from 120±20 min to 80±15 min (p<0.05) and reduced the number of frozen sections from 2.2±0.4 to 1.1±0.3 (p<0.001). MIBI scintigraphy is the most efficient modality for preoperative localization of parathyroid adenoma as compared to other imaging procedures, and can shorten operative time (Au)

  16. Clinical evaluation of 99Tcm-MIBI myocardial perfusion imaging for the detection of coronary artery disease in patients with metabolic syndrome

    International Nuclear Information System (INIS)

    Tian Yueqin; Wei Hongxing; Guo Xinhua; Guo Feng; He Zuoxiang

    2008-01-01

    Objective: Metabolic syndrome is a combination of medical disorders that consist of a collection of independent factors at risk of developing coronary artery disease. The purpose of this study was to evaluate the value of 99 Tc m -methoxyisobutylisonitrile (MIBI) myocardial perfusion imaging for the diagnosis of coronary artery disease in patients with metabolic syndrome. Methods: A total of 251 patients [mean age (59 ± 10) years, 179 men, 72 women] were included in this study. All patients underwent exercise and rest 99 Tc m -MIBI myocardial perfusion imaging and coronary angiography. Results: Of the 163 patients with significant coronary artery stenosis, 116 showed abnormal 99 Tc m -MIBI myocardial perfusion imaging; and among the 88 patients with normal coronary angiography, 82 showed normal myocardial perfusion imaging. The sensitivity, specificity and accuracy of 99 Tc m -MIBI myocardial perfusion imaging for coronary artery disease detection were 71% (116/163), 93% (82/88) and 79% (198/251), respectively. The positive and negative predictive values were 95% (116/122) and 64% (82/129), respectively. Conclusion: 99 Tc m -MIBI myocardial perfusion imaging has important clinical value for detecting coronary artery disease in patients with metabolic syndrome. (authors)

  17. Study of gels of molybdenum with cerium in the preparation of generators of 99Mo - 99mTc

    Directory of Open Access Journals (Sweden)

    Vanessa Moraes

    2005-10-01

    Full Text Available 99mTc has ideal nuclear properties for organ imaging in nuclear medicine, and it is obtained from the 99Mo-99mTc generator. Four different types of generators are available: chromatographic that uses 99Mo from fission of uranium; MEK solvent extraction; Tc2O7 sublimation; gel chromatographic. This work presents the preparation of gel generators of molybdenum with cerium and characterization of the gels: mass ratio between molybdenum and cerium, structure, size of particles and elution percentage of 99mTc after irradiating the gels. Eight gels were prepared at the same temperature of 50 ºC with concentrations of NaOH of 2 and 4 mol/L, mass ratio of 0.31 and 0.38 and final pH of 3.5 and 4.5. The analysis of the results proved that these gels are not adequate for preparation of the generators of 99Mo-99mTc, since the elution percentages are low, when compared with the gel of molybdenum with zirconium.O 99mTc é o radiofármaco mais utilizado em Medicina Nuclear. Ele é obtido do gerador de 99Mo-99mTc e existem quatro tipos diferentes de geradores: cromatográfico que utiliza 99Mo de fissão; extração por solvente com MKT; sublimação do heptaóxido de tecnécio; cromatográfico tipo gel. Este trabalho apresenta a preparação de geradores tipo gel de molibdênio com cério, a caracterização desses géis com relação à quantidade de molibdênio e de cério, sua estrutura, tamanho das partículas e porcentagem de eluição do 99mTc após o gel ser irradiado. Foram preparados oito géis na temperatura de 50ºC com concentração de NaOH de 2 e 4 mol/L, relação de massa de 0,31 e 0,38 e pH final de 3,5 e 4,5. A análise dos resultados comprovou que esses géis não são adequados para preparação dos geradores de 99Mo-99mTc, já que as porcentagens de eluição são baixas, quando comparadas com o gel de molibdênio com zircônio.

  18. Effect of acidity and chemical composition of sup(99m)Tc-radiopharmaceuticals on sup(99m)Tc accumulation in necrotic tissue of rat myocardium

    Energy Technology Data Exchange (ETDEWEB)

    Vilcek, S; Machan, V; Kalincak, M [Ustav Radioekologie a Vyuzitia Jadrovej Techniky, Kosice (Czechoslovakia); Nicak, A [Univerzita P.J. Safarika, Kosice (Czechoslovakia). Lekarska Fakulta

    1981-04-30

    Experiments showed that the cumulation of technetium-99m following the administration of /sup 99m/Tc-Sn-pyrophosphate and s/sup 99m/Tc-Sn-oxytetracycline in the necrotic tissue of rat myocardium damaged by cauterization depended on the end pH value. The maximum /sup 99m/Tc cumulation in the myocardial lesion was noted when the end pH value ranged in 5.5 to 6.0. It appeared that pyrophosphate concentration decrease below the critical limit not only affected the cumulation of /sup 99m/Tc in the particular organs but also in the necrotic tissue of the myocardium.

  19. Effect of acidity and chemical composition of sup(99m)Tc-radiopharmaceuticals on sup(99m)Tc accumulation in necrotic tissue of rat myocardium

    International Nuclear Information System (INIS)

    Vilcek, S.; Machan, V.; Kalincak, M.; Nicak, A.

    1981-01-01

    Experiments showed that the cumulation of technetium-99m following the administration of sup(99m)Tc-Sn-pyrophosphate and sup(99m)Tc-Sn-oxytetracycline in the necrotic tissue of rat myocardium damaged by cauterization depended on the end pH value. The maximum sup(99m)Tc cumulation in the myocardial lesion was noted when the end pH value ranged in 5.5 to 6.0. It appeared that pyrophosphate concentration decrease below the critical limit not only affected the cumulation of sup(99m)Tc in the particular organs but also in the necrotic tissue of the myocardium. (author)

  20. Diagnostic value of dilatation of the left ventricular cavity on exercise 99Tcm-MIBI imaging for coronary artery disease

    International Nuclear Information System (INIS)

    Zhang Xiangsong; Tang Anwu; Zhang Bin; Liu Bin; Xu Weiping

    2000-01-01

    Objective: To investigate the diagnostic value of dilatation of the left ventricular cavity on exercise 99 Tc m -MIBI imaging for triple-vessel disease. Methods: Exercise and rest myocardial perfusion imaging were performed on 76 patients with known angiograms. The exercise/rest ratio of the left ventricular dimension (LVD) from the 99 Tc m -MIBI imaging was defined as the left ventricular dilatation ratio (LVDR). Results: 21 of 76 patients showed an abnormal LVDR, and 19 of the 21 patients (90%) had triple-vessel disease. By routine analysis method, the sensitivity and specificity for diagnosing triple-vessel disease was 50% and 91%, respectively, whereas LVDR had a sensitivity of 82% and a specificity of 94%. When LVDR was used in combination with the routine analysis method, sensitivity increased to 91% without a significant loss of specificity. Conclusions: Quantitatively analysis of the dilatation of the left ventricular cavity on exercise 99 Tc m -MIBI imaging could increase the sensitivity for diagnosing triple-vessel disease and provide complementary information to exercise 99 Tc m -MIBI imaging

  1. The key role of {sup 99m}Tc-MIBI SPECT/CT in the diagnosis of parathyroid adenoma: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Li, Qing; Pan, Jiemin; Luo, Quanyong; Wang, Yan; Bao, Yuqian; Jia, Weiping, E-mail: wpjia@sjtu.edu.cn, E-mail: wpjia@yahoo.com [Shanghai Jiao Tong University Affiliated Sixth People' s Hospital, Shanghai (China)

    2015-06-15

    The concomitant occurrence of primary hyperparathyroidism (PHPT) due to parathyroid adenoma and papillary thyroid carcinoma (PTC) is not common. The co-occurrence of parathyroid tumors and thyroid diseases can lead to misdiagnosis owing to mutual interference of imaging in the early period of disease. The most commonly used imaging techniques for the preoperative localization of parathyroid and thyroid adenomas are technetium-99m sestamibi ({sup 99m}Tc-MIBI) scintigraphy and ultrasonography of the neck. Recently, {sup 99m}Tc-MIBI single-photon emission computed tomography associated with computed tomography scintigraphy (SPECT/CT) has been used to detect PHPT, and its diagnostic value is being evaluated. Herein, we report a patient with an unusual co-occurrence of parathyroid adenoma and multiple thyroid diseases, including papillary thyroid carcinoma, thyroid adenoma and lymphocytic thyroiditis, which were localized with {sup 99}mTc-MIBI SPECT/CT and confirmed surgically. We suggest that {sup 99m}Tc-MIBI SPECT/CT can play an important role in the diagnosis of parathyroid and thyroid lesions. (author)

  2. Development of MIBI kit for heart imaging

    International Nuclear Information System (INIS)

    Khamis, S.B.; Ab-Wahid, M.

    1998-01-01

    99m Tc-isonitriles have been shown to be a very promising substitute for Thallium-201 ( 201 TI) for myocardial perfusion imaging. In this study, the lyophilized kit of Methoxyisobutylisonitrile (MIBI) was prepared and labeled with 99m Tc. Several factors affecting the labeling yield such as the kit's stannous content, boiling time during labeling, and the volume of 99m Tc used during reconstitution were also investigated. The radiochemical purity (RCP) determination of the labeled product was analyzed by HPLC, solvent-extraction, TLC and ITLC-SG chromatographic methods in various systems. Animal biodistribution study performed in rats indicated the 99m Tc-MIBI accumulation in the myocardial is up to 3 hours with little or no redistribution. Toxicity studies performed indicate no clinical signs of abnormality in mice at injected dose equivalent in amount of 100 times the human dose in proportion to body weight. Stability studies of the labeled complex performed at room temperature showed no change in radiochemical purity (> 95%) 6 hours post-preparation. Compatibility and comparative studies were done using both MINT and commercially available MIBI kits and 99m Tc generator eluates. From the results obtained the MINT produced MIBI kits were found to be comparable in quality to that of commercials. (author)

  3. Correlation of single image Tc-99m MIBI scan and ultrasonography with fine needle aspiration cytology (FNAC) to assess neoplasia in solitary 'cold' thyroid nodules

    International Nuclear Information System (INIS)

    Sohaib, M.; Saeed, S.; Naseeb, H.K.; Hyder, S.W.

    2007-01-01

    Various investigative approaches for the management of solitary thyroid nodules have been adopted, which involve Tc-99m pertechnetate scan, ultrasonography and fine needle aspiration cytology (FNAC). Incidence of neoplasm in a solitary thyroid nodule showing cold lesion on Tc-99m pertechnetate scan vary from 9 to 26%. In the current study we evaluated the utility of Tc-99m labeled Hexakis2- methoxyisobutyl isonitrile (Tc-99m MIBI) in differentiating neoplastic from non-neoplastic lesions among nodules which are cold on Tc-99m pertechnetate scan and solid or mixed on ultrasonography. Forty-nine patients, all having solitary cold nodules on Tc-99m Pertechnetate scans were included in the study. All underwent ultrasonography, Tc- 99m MIBI scan and FNAC. Ultrasound findings were categorized as solid, mixed and cystic. Anterior images of thyroid were acquired 15 minutes after intravenous injection of Tc-99m MIBI. The thyroid nodules were classified into 5 categories depending on the degree of MIBI uptake. They were; Category-1 showing intense uptake, Category -2 showing slightly higher uptake than the surrounding normal thyroid tissue, Category - 3 with uptake equal to the normal thyroid, Category -4 showing less uptake than the surrounding normal tissue and Category -5 showing no or negligible uptake of Tc-99m MIBI. Receiver Operating Characteristic (ROC) curve was generated using Tc-99m MIBI results. FNAC revealed 10 nodules with neoplastic lesions (8 follicular and two pleomorphic), 29 with colloid goiter and 5 with benign cystic lesions. Tc-99m MIBI images revealed Categories- 1,2,3,4 and 5 scintigraphic patterns in 2,12, 11, 10 and 14 patients respectively. One patient in Category 1 and 9 in Category 2 proved to be neoplastic in nature, while none of the patients in category 3 to 5 had evidence of neoplasm on FNAC. The ROC curve revealed excellent performance of Tc-99m MIBI scan in diagnosing neoplastic lesions in the solitary cold thyroid nodules. Considering

  4. A comparison of radionuclide thyroid angiography, {sup 99m}Tc-MIBI scintigraphy and power Doppler ultrasonography in the differential diagnosis of solitary cold thyroid nodules

    Energy Technology Data Exchange (ETDEWEB)

    Demirel, Koray; Kapucu, Oezlem [Department of Nuclear Medicine, Gazi University School of Medicine, Ankara (Turkey); Yuecel, Cem; Oezdemir, Hakan [Department of Radiology, Gazi University School of Medicine, Ankara (Turkey); Ayvaz, Goeksun [Department of Endocrinology and Metabolic Diseases, Gazi University School of Medicine, Ankara (Turkey); Taneri, Ferit [Department of Surgery, Gazi University School of Medicine, Ankara (Turkey)

    2003-05-01

    We prospectively studied 43 patients with solitary cold thyroid nodules greater than 1.5 cm in diameter to determine the comparative diagnostic value of radionuclide thyroid angiography (RTA), technetium-99m methoxyisobutylisonitrile ({sup 99m}Tc-MIBI) scintigraphy and power Doppler ultrasonography (PDUS) in the differentiation of benign and malignant thyroid nodules. Perfusion of the nodules in RTA was compared with the perfusion in the surrounding normal thyroid tissue and classified as follows: 0, avascular; 1, hypovascular; 2, isovascular; 3, hypervascular. {sup 99m}Tc-MIBI uptake in the nodules compared with that in surrounding thyroid tissue was scored for both early and delayed images as follows: 0, cold; 1, decreased; 2, equal; 3, increased. PDUS patterns were classified as nodule vascularisation patterns. The malignancy criteria were set as follows: hypervascular nodule with rapid washout in RTA; complex ring sign with anarchic structure or delta sign in PDUS, and positive retention and increased uptake in the nodule in the early and delayed {sup 99m}Tc-MIBI images. These data were compared with the histopathological results. Histology revealed thyroid carcinoma in nine patients (five cases of papillary carcinoma, three of follicular carcinoma and one of medullary carcinoma) and benign conditions in 34 patients (30 cases of nodular goitre, three of lymphocytic thyroiditis and one of follicular adenoma). Sensitivity, specificity and accuracy were, respectively, 0.89, 1.00 and 0.97 for RTA, 1.00, 0.76 and 0.81 for PDUS, and 0.67, 0.91 and 0.86 for {sup 99m}Tc-MIBI scintigraphy (when nodules with increased uptake in both the early and the delayed images and a positive retention index were considered as malignant). RTA, {sup 99m}Tc-MIBI scintigraphy and PDUS could be helpful in the preoperative assessment of solitary cold thyroid nodules. In this study, RTA was found to be the most accurate and specific method for differentiation of malignant from benign

  5. Osteomyelitis diagnosis by {sup 99m}Tc radiolabeled aptamers

    Energy Technology Data Exchange (ETDEWEB)

    Santos, S.R.; Ferreira, I.M.; Andrade, A.S.R., E-mail: sararoberta7@hotmail.com, E-mail: imendesf@yahoo.com.br, E-mail: antero@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Barros, A.L.B.; Cardoso, V.N.; Diniz, O.F., E-mail: brancodebarros@yahoo.com.br, E-mail: valbertcardoso@yahoo.com.br, E-mail: simoneodilia@yahoo.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Faculdade de Farmacia. Departamento de Analises Clinicas e Toxicologicas

    2015-07-01

    Osteomyelitis, which is characterized by progressive inflammatory destruction and new opposition of bone, is still a difficult infection to treat. The clinical diagnosis in late stages is achieved easily, but an early diagnosis is more challenging. Staphylococcus aureus is a common agent found in osteomyelitis and bone prostheses infection. Diagnosis by scintigraphy has advantages because it is a non-invasive procedure and is able to perform an early diagnosis even before anatomic changes. Thus, nuclear medicine could contribute to an accurate diagnosis since specific radiopharmaceuticals were developed. In this study, aptamers selected to Staphylococcus aureus were labeled with {sup 99m}Tc and used for bacteria identification in an osteomyelitis experimental model. The aptamers selected to S. aureus were directly labelled with {sup 99m}Tc and were evaluated by biodistribution studies. Wistar rats with intraosseous infection in the right paw were used. A random aptamer labelled with {sup 99m}Tc was as control. Six animals were used in each group. The aptamers labeled with {sup 99m}Tc were able to identify the infection foci caused by S. aureus displaying a target/non-target ratio of 2,23 ± 0,20, after 3 h. The control group presented a target/non-target ratio 1,08 ± 0.23. The results indicated that the radiolabeled aptamers were able to identify specifically the infection foci and they should be further explored for infection diagnosis by scintigraphy. (author)

  6. The value of Tc-99m MIBI scintigraphy in active disease and remission phase of multiple myeloma

    International Nuclear Information System (INIS)

    Saghari, M.; Fallahi, B.; Eftekhari, M.; Irvani, M.; Izadyar, S.; Esmaili, J.; Beiki, D.; Fard, A.

    2004-01-01

    Background: 99m Tc methoxy isobutyl isonitrile ( 99m Tc -MIBI)has been proposed as a tumor seeking agent in malignant disease. The goal of this study is to evaluate the frequency distribution of the different patterns, intensity and extension of abnormal uptake identified in MIBI scan in relation with various clinical status of the patients diagnosed as a multiple myeloma. Methods: forty-three patients entered the study, including six patients with no prior treatment , 22 patients who received autologous bone morrow graft, and 15 patients with history of chemotherapy and radiotherapy. Plasma protein electrophoresis for monoclonal antibody, bone morrow biopsy and urine analysis for Bence-Jones protein has been carried out and standard criteria were used for diagnosis of active disease and remission phase for each patients. The extension of each lesion(E-score) on scintigraphy were categorized into E 0 -E 3 by three nuclear physicians who were blinded to the patient's clinical condition. I-score was also obtained with comparing the intensity of the lesions with intensity of myocardial uptake and classified as I 0 -I 3 . Results: the sensitivity, specificity, positive predictive value and negative predictive value of 99m Tc -MIBI scan for determining active lesions and released cases were 69%, 100%, 100% and 60%, respectively. Nineteen patients were initially thought to be in remission phase, but scintigraphy was abnormal in 5 cases who were diagnosed as active myeloma later in the course of the study. There was a significant correlation between clinical status and pattern, intensity and extension of the abnormal uptake of 99m Tc -MIBI. Also a significant correlation between intensity and extension of the abnormal tracer uptake with serum monoclonal component and urine Bence-Jones protein was noted, however no correlation between blood hemo globulin and degree of extension in scintigraphy was seen. Conclusion: Our study suggests the pattern, extension and intensity of

  7. Mandibular brown tumor revealing primary hyperparathyroidism. Contribution of the 99Tc-MIBI scintigraphy (report of case)

    International Nuclear Information System (INIS)

    Bahri, H.; Mhiri, A.; Zayed, S.; Letaief, B.; Slim, I.; Kraiem, T.; Ben Slimen, M.F.; Sellem, A.; Hammami, H.; Ladgham, A.

    2006-01-01

    Thanks to the development of new diagnostic and therapeutic techniques, it has became rare to discover a primary hyperparathyroidism at the stage of renal and/or bony complications. The contribution of the 99m Tc-MIBI scintigraphy has been well described in the detection of the parathyroid adenoma but few publications showed its capacity to detect also brown tumors. We report a case of mandible brown tumor, revealing a primary hyperparathyroidism. 99m Tc-MDP scintigraphy, done in the setting of the bony lesion balance, showed the multifocal character of this tumor. 99m Tc-MIBI scintigraphy pointed out both parathyroid adenoma and brown tumor that fixed the radio tracer. (author)

  8. PENGARUH REGENERASI KOLOM ALUMINA ASAM TERHADAP RECOVERY DAN KUALITAS 99mTc HASIL EKSTRAKSI PELARUT MEK DARI 99Mo HASIL AKTIVASI NEUTRON

    Directory of Open Access Journals (Sweden)

    Adang H G

    2017-01-01

    Full Text Available ABSTRAK PENGARUH REGENERASI KOLOM ALUMINA ASAM TERHADAP RECOVERY DAN KUALITAS 99mTc HASIL EKSTRAKSI PELARUT MEK DARI 99Mo HASIL AKTIVASI NEUTRON. Melalui kerjasama antara PTRR-BATAN, Chiyoda dan JAEA Jepang telah dilakukan pemurnian 99mTc dari 99Mo hasil aktivasi neutron dengan menggunakan metode kromatografi kolom alumina asam terhadap hasil ekstraksi MEK (Metil Etil Keton. Pemurnian 99mTc dengan metode kolom alumina asam hanya dapat digunakan satu kali dan pemurnian berikutnya harus diganti dengan kolom baru. Hal ini dinilai kurang praktis dan juga memerlukan biaya yang mahal. Dalam penelitian ini dicoba penggunaan kolom alumina asam untuk pemurnian 99mTc lebih dari satu kali dengan melakukan proses regenerasi dengan cara melewatkan larutan HNO3 0,1N setiap kali proses pemurnian selesai. Penelitian ini bertujuan untuk mendapatkan larutan 99mTc yang dapat digunakan untuk penandaan kit radiofarmaka. Parameter yang diamati dalam penelitian ini adalah recovery, profil elusi, pH, kemurnian radiokimia dan kemurnian radionuklida (lolosan 99Mo. Hasil penelitian yang dilakukan selama 5 hari telah diperoleh pH ~5, recovery > 60 %, kemurnian radiokimia > 95 % dan lolosan 99Mo tidak terdeteksi. Dari hasil perlakuan terhadap kolom alumina asam dengan larutan HNO3 0,1 N disimpulkan bahwa kolom alumina asam tidak perlu diganti setiap hari. Kata kunci: 99mTc, 99Mo, MEK, kolom alumina asam, kemurnian radiokimia. ABSTRACT Purification of 99mTc from 99Mo activation using acidic alumina column chromatography system from MEK (Methyl Ethyl Keton extraction has been carried out through cooperation between PTRR - BATAN, Chiyoda and JAEA Japan. This method has a limitation that acidic alumina column for purification of 99mTc can be used only once, for the next purification acidic alumina column should be replaced with new column, so it is less practical and also requires high cost. This study aims to obtain a 99mTc solution can be use for labelling of a

  9. Contribution of the Technetium-99m-sestamibi (MIBI) scintigraphy in primary hyperparathyroidism to determination of parathyroidectomy

    International Nuclear Information System (INIS)

    Nishida, Takuro; Hayakawa, Katsumi; Nishimura, Kazumasa; Kawakami, Satoshi; Sakamoto, Makoto; Koh, Toshikiyo; Hida, Shuichi

    1999-01-01

    We reviewed retrospectively the 12 patients who underwent parathyroidectomy because of hyperparathyroidism and judged to what degree the Technetium-99m-sestamibi (MIBI) scintigraphy contributed to determination of parathyroidectomy. From the view point that weather parathyroidectomy could be decided without the MIBI scintigraphy, we classified the cases into three groups; great, fair, and poor contribution. We judged 4 cases as great contribution, 5 cases as fair contribution and 3 cases as poor contribution. We concluded that if the MIBI scintigraphy is positive in patients with primary hyperparathyroidism, parathyroidectomy is strongly recommended, because of its high sensitivity and accuracy for detection of parathyroid adenomas and because there were no false-positive cases with the MIBI scintigraphy. (author)

  10. Alterations in electrocardiogram of adenosine test for 99Tcm-MIBI myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Xie Boqia; Tian Yueqin; Zheng Lihui

    2011-01-01

    Objective: To analyze alterations in electrocardiogram (ECG) of adenosine test in 99 Tc m -MIBI myocardial perfusion imaging(MPI)SPECT study. Methods: A total of 641 patients were included in the study. The patients each underwent 99 Tc m -MIBI MPI with adenosine test. The ECGs were taken before, during, and after adenosine infusion. Results: In all, abnormal ECGs were found in 205(32.0%) patients. During adenosine infusion, 20.6%(132/641) of patients suffered from arrhythmia, 29.5%(39/132) had atrial premature beats, 34.1% (45/132) had premature ventricular beats, and 6.1% (8/132) had sinoatrial block. In addition, 5.3% (7/132) had first-, 24.2% (32/132) had second-, and 0.8% (1/132) had third-degree atrioventricular block (AVB). After adenosine infusion, 4.4%( 28/641) of patients suffered from arrhythmia, 57.1% (16/28) had atrial premature beats, 39.3% (11/28) had premature ventricular beats, and 3.6% (1/28) had sinoatrial block. The perfusion images showed ischemia in 36 patients and infarction in 8 patients. Adenosine infusion was terminated in 39 patients (6.1%) because of poorly tolerated side effects. However, no death or acute myocardial infarction occurred in the study. Conclusions: Adenosine pharmacologic test for 99 Tc m -MIBI MPI may result in relatively high incidence of arrhythmia in ECG monitoring. (authors)

  11. 29 CFR 99.315 - Audit findings follow-up.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Audit findings follow-up. 99.315 Section 99.315 Labor Office... § 99.315 Audit findings follow-up. (a) General. The auditee is responsible for follow-up and corrective... include the reference numbers the auditor assigns to audit findings under § 99.510(c). Since the summary...

  12. 99Tcm-MIBI imaging in diagnosing benign/malign pulmonary disease and analysis of lung cancer DNA content

    International Nuclear Information System (INIS)

    Feng Yanlin; Tan Jiaju; Yang Jie; Zhu Zheng; Yu Fengwen; He Xiaohong; Huang Kemin; Yuan Baihong; Su Shaodi

    2002-01-01

    Objective: To evaluate the value of 99 Tc m -methoxyisobutylisonitrile (MIBI) lung imaging in diagnosing benign/malign pulmonary disease and the relation of 99 Tc m -MIBI uptake ratio (UR) with lung cancer DNA content. Methods: Early and delay imaging were performed on 27 cases of benign lung disease and 46 cases of malign lung disease. Visual analysis of the images and T/N uptake ratio measurement were performed on every case. Cancer cell DNA content and DNA index (DI) were measured in 24 cases of malign pulmonary disease. Results: The delay phase UR was 1.13 ± 0.19 in benign disease group, and the delay phase UR was 1.45 ± 0.21 in malign disease group (t6.51, P 99 Tc m -MIBI is not an ideal imaging agent for differentiating pulmonary benign/malign disease. Lung cancer DNA content may be reflected by delay phase UR

  13. Determination of 99Mo contamination in 99mTc elute obtained from 99Mo/99mTc- generator

    International Nuclear Information System (INIS)

    Momennezhad, M.; Zakavi, S. R.; Sadeghi, R.

    2010-01-01

    99m Tc is a widely used radioisotope in nuclear medicine centers which is obtained by elution from Mo-99/Tc-99m generators. Usually the generators are either supplied by the Iran Atomic Energy Agency or by private companies from foreign countries. In this study we have measured 99 Mo contamination in 99m Tc elute from different generators in a period of one year. Materials and Methods: The radionuclide impurity of the 99m Tc elute were studied in two types of radionuclide generators (A: produced in Iran and B: Imported from other country). In-vitro measurements were performed using dose calibrator. Direct measurements were made, using a standard canister at the time of milking of the generators and also in Subsequent hours after milking. Results: The results showed a mean of 99 Mo impurity in generators A and B to be 0.00932±0.0043 and 0.0170±0.0127 respectively. Although the results showed that the 99 Mo contamination in 99 mTc elute was lesser than the maximum accepted activity limit of 0.015%, the difference in these two types may reflect different methods of productions of generator, as well as the quality control procedures. Conclusion: The mean of 99 Mo contamination in generators produced in Iran Atomic Energy Organization was lesser than generators imported from foreign origin.

  14. Correlation between the Histo-Pathological Grade and Tumour Uptake Analysis of Tc99m-MIBI in Breast Cancer Nodules

    International Nuclear Information System (INIS)

    Haider, Saima

    2006-01-01

    Full text: Breast Cancer is the most common malignancy among women in the world. X-Ray mammography is the best screening device, but radionuclide imaging such as Tc-99m MIBI Scintimammography promises to play an important role as an adjunctive functional imaging tool in breast malignancies. The aim of the study was to correlate the Histopathological grade and semi-quantitative analysis of tracer uptake in Tc-99m MIBI Scintimammography. Seven (7) female patients (mean age 47.5+10) with locally advanced breast cancer were imaged. Informed written consent was taken from each patient. Average of 950 MBq (0.3 mCi/kg) Tc-99m MIBI was injected intravenously in the contra lateral arm to the site of lesion. Static prone MIBI Scintimammoscans of the affected side was acquired 5-10 minutes post injection for 10 minutes. Similarly 10 minute static view of normal side was also done. The background subtracted lesions to normal ratios (LNR) were acquired. Histopathological grading of tumours was done according to Bloom Richardson grading system. All the tumours were infiltrating ductal carcinoma. The mean LNR value is higher in high-grade lesions while less in low-grade tumours. Higher un-differentiation of malignant tumour is related with aggressive nature of the disease. This would suggest that more aggressive tumours have higher uptake of Tc-99m MIBI and therefore greater invasiveness of malignancy. (author)

  15. Multimodal imaging NMR-{sup 99m}Tc-MIBI Spect to guide stereotactic biopsy: a case report; A propos d'un cas d'intervention neurochirurgicale guidee par l'imagerie multi-modalite IRM-TEMP au {sup 99m}Tc-MIBI

    Energy Technology Data Exchange (ETDEWEB)

    Prigent-Le Jeune, F.; Coste, E.; Perez, S.; Lecouffe, P.; Steinling, M. [Hopital Roger Salengro, CHRU, Service Central de Medecine Nucleaire, UF de Neurologie, 59 - Lille (France); Dubois, F.; Blond, S. [Hopital Roger Salengro, CHRU, Service de Neurologie, 59 - Lille (France)

    2001-03-01

    Multimodal imaging is the simultaneous and co-registered use of images issued from different modalities in order to improve the information quality and the pathology diagnosis. We have developed a registration method between cerebral {sup 99m}Tc-MIBI tomo-scintigraphy and MRI, easy to use in standard clinical practice for cerebral glioma follow up. This paper presents the follow-up of a patient, having an abnormal tracer uptake without any clinical or neuro-morphological disorder. The registered images helped the neurosurgeon to define the stereotactic biopsy trajectory according to the abnormal uptake area position. The histological analysis demonstrated a high grade recurrence. This clinical case confirms the contribution of the multimodal imaging, in the pre-operative planning of neurosurgical stereotactic biopsy, in order to accurately localize the tumour recurrence on the anatomical images. (authors)

  16. Molecular imaging with (99m)Tc-MIBI and molecular testing for mutations in differentiating benign from malignant follicular neoplasm: a prospective comparison.

    Science.gov (United States)

    Giovanella, L; Campenni, A; Treglia, G; Verburg, F A; Trimboli, P; Ceriani, L; Bongiovanni, M

    2016-06-01

    To compare mutation analysis of cytology specimens and (99m)Tc-MIBI thyroid scintigraphy for differentiating benign from malignant thyroid nodules in patients with a cytological reading of follicular neoplasm. Patients ≥18 years of age with a solitary hypofunctioning thyroid nodule (≥10 mm), normal thyrotropin and calcitonin levels, and a cytological diagnosis of follicular neoplasm were prospectively enrolled. Mutation analysis and (99m)Tc-MIBI scintigraphy were performed and patients were subsequently operated on to confirm or exclude a malignant lesion. Mutations for KRAS, HRAS and NRAS and for BRAF and translocations of PAX8/PPARγ, RET/PTC1 and RET/PTC3 were investigated. Static thyroid scintigraphic images were acquired 10 and 60 min after intravenous injection of 200 MBq of (99m)Tc-MIBI and visually assessed. Additionally, the MIBI washout index was calculated using a semiquantitative method. In our series, 26 % of nodules with a follicular pattern on cytology were malignant with a prevalence of follicular carcinomas. (99m)Tc-MIBI scintigraphy was found to be significantly more accurate (positive likelihood ratio 4.56 for visual assessment and 12.35 for semiquantitative assessment) than mutation analysis (positive likelihood ratio 1.74). A negative (99m)Tc-MIBI scan reliably excluded malignancy. In patients with a thyroid nodule cytologically diagnosed as a follicular proliferation, semiquantitative analysis of (99m)Tc-MIBI scintigraphy should be the preferred method for differentiating benign from malignant nodules. It is superior to molecular testing for the presence of differentiated thyroid cancer-associated mutations in fine-needle aspiration cytology sample material.

  17. Non-Q-wave myocardial infarction: impaired myocardial energy metabolism in regions with reduced 99mTc-MIBI accumulation.

    Science.gov (United States)

    Moka, D; Baer, F M; Theissen, P; Schneider, C A; Dietlein, M; Erdmann, E; Schicha, H

    2001-05-01

    Reduced regional technetium-99m methoxyisobutylisonitrile (99mTc-MIBI) accumulation in patients with chronic non-Q-wave infarction (NQWI) but without significant coronary artery stenosis indicates non-transmural damage of the myocardial wall. The aim of this study was to characterise cardiac energy metabolism after NQWI using phosphorus-31 magnetic resonance spectroscopy (31P-MRS) and to compare the biochemical remodelling with changes in regional 99mTc-MIBI uptake and with morphological and functional parameters assessed by magnetic resonance imaging (MRI). Fifteen patients with a history of NQWI, exclusion of significant coronary artery stenosis (energy metabolism. Spectroscopic measurements were performed in the infarct-related myocardial region. Corresponding gradient-echo MR images and myocardial 99mTc-MIBI single-photon emission tomography images were acquired for exact localisation of the infarct region. All examinations were performed at rest under anti-ischaemic medication. Data were compared with those of patients in whom coronary artery disease had been excluded by angiography (group B, n=10). All patients of group A displayed anterior wall hypokinesia in the infarcted area on both ventriculography and MRI, with a reduced myocardial accumulation of 99mTc-MIBI (66.3%+/-11.8% vs 95.6%+/-2.2% in group B). The mean wall thickness during the complete cardiac cycle (9.5+/-1.8 mm vs 13.1+/-1.1 mm in group B, Penergy metabolism.

  18. Production of kits for the labelling with 113sup(m)In and sup(99m)Tc, at the CNEA

    International Nuclear Information System (INIS)

    Palcos, M.C.; Kurcbart, Horacio; Nowotny, G.; Ramos, Elsa; Riesgo, J.G.; Mitta, A.E.A.

    1978-05-01

    The actual state of the production of radiopharmaceuticals in the form of reagents kits at the C.N.E.A. is described. This could allow the users to label compounds with sup(113m)In and sup(99m)Tc in an easy and reproducible way. At present, the following sets are provided routinarily a) To label with sup(99m)Tc: Albumin macroaggregates: calcium gluconate; antimonium sulfide colloid, sodium phytate; sodium calcium DTPA; seroalbumin; sodium pyrophosphate; sodium citrate. b) To label with sup(113m)In: albumin macroaggregates; PVP-bicarbonate; DTPA; human seroalbumin. Regarding products in a developping stage, we have: to labed with sup(99m)Tc: dimercapto-succinic acid, set for the labelling of human erythrocytes, set for sup(113m)In and sup(99m)Tc concentration and bleomicin; to label with sup(113m)In: EDTMP sup(99m)In. (author) [es

  19. Effect of iron deficiency anemia on the biodistribution of {sup 99m}Tc radiopharmaceuticals

    Energy Technology Data Exchange (ETDEWEB)

    Calmanovici, Gabriela P. [Radioisotopes Laboratory, Physics Department, School of Pharmacy and Biochemistry, University of Buenos Aires, Junin 956 - 1113, Buenos Aires (Argentina); Salgueiro, Maria J. [Radioisotopes Laboratory, Physics Department, School of Pharmacy and Biochemistry, University of Buenos Aires, Junin 956 - 1113, Buenos Aires (Argentina); Janjetic, Mariana A. [Physics Department, School of Pharmacy and Biochemistry, University of Buenos Aires, Junin 956 - 1113, Buenos Aires (Argentina); Leonardi, Natalia M. [Radioisotopes Laboratory, Physics Department, School of Pharmacy and Biochemistry, University of Buenos Aires, Junin 956 - 1113, Buenos Aires (Argentina); Boccio, Jose R. [Physics Department, School of Pharmacy and Biochemistry, University of Buenos Aires, Junin 956 - 1113, Buenos Aires (Argentina); Zubillaga, Marcela B. [Radioisotopes Laboratory, Physics Department, School of Pharmacy and Biochemistry, University of Buenos Aires, Junin 956 - 1113, Buenos Aires (Argentina)]. E-mail: mzubi@ffyb.uba.ar

    2006-05-15

    The distribution of colloids and labeled cells in organs is influenced by their intrinsic properties and by the state of the investigated subject. Iron deficiency remains an unsolved nutritional problem all over the world; one of its severe consequences is anemia. Because iron metabolism principally takes place in the liver, spleen, bone marrow, skeletal muscle and blood, we studied the effect of iron deficiency anemia on the biodistribution of {sup 99m}Tc phytate, {sup 99m}Tc gelatin colloid and {sup 99m}Tc RBC (red blood cells labeled with {sup 99m}Tc). Our results show that iron deficiency anemia modifies the pattern of biodistribution of the two colloids assayed. However, this behavior is different for both of them. This work contributes to studies that kinetically and statistically establish that iron deficiency anemia induces a significant inversion in the spleen-liver activity relationship when centellographic studies are performed with colloids such as {sup 99m}Tc phytate.

  20. A new approach for manufacturing and processing targets to produce 99mTc with cyclotrons

    Science.gov (United States)

    Matei, L.; McRae, G.; Galea, R.; Niculae, D.; Craciun, L.; Leonte, R.; Surette, G.; Langille, S.; Louis, C. St.; Gelbart, W.; Abeysekera, B.; Johnson, R. R.

    2017-06-01

    The most important radioisotope for nuclear medicine is 99mTc. After the supply crisis of 99Mo starting in 2008, the availability of 99mTc became a worldwide concern. Alternative methods for producing the medical imaging isotope 99mTc are actively being developed around the world. The reaction 100Mo(p, 2n)99mTc provides a direct route that can be incorporated into routine production in nuclear medicine centers that possess medical cyclotrons for production of other isotopes, such as those used for Positron Emission Tomography. This paper describes a new approach for manufacturing targets for the (p, 2n) nuclear reaction on 100Mo and the foundation for the subsequent commercial separation and purification of the 99mTc produced. Two designs of targets are presented. The targets used to produce 99mTc are subject to a number of operational constraints.They must withstand the temperatures generated by the irradiation, accommodate temperature gradients from cooling system of the target, must be resilient and must be easily post-processed to separate the 99mTc. After irradiation, the separation of Tc from Mo was carried out using an innovative two-step approach. The process described in this paper can be automated with modules that easily fit in standard production hot cells found in nuclear medicine facilities.

  1. A reliable method for the quality control of 99mTc-MIBI prepared using fractionated cardiolite kits

    International Nuclear Information System (INIS)

    Poot, M.T.; Varelis, P.

    1998-01-01

    Full text: The reconstitution of fractionated Cardiolite kits with Na[ 99m Tc]TcO 4 eluted from a wet-column generator results in a preparation that contains elevated amounts of a polar radiochemical impurity, which is normally present in only trace amounts when such kits are reconstituted with eluate from a dry-column generator. We demonstrate, using HPLC, that this impurity causes a positive bias in several reported quality control methods (TLC, ITLC and SPE) for 99m Tc-MIBI, including that recommended by the manufacturer (TLC). A rapid procedure, based on a C18 solid phase extraction (SPE) cartridge, for measuring the radiochemical purity (RCP) of 99m Tc-MIBI samples was developed and compared with three other methods including HPLC. Over a RCP range of 49-98%, the values obtained using our SPE method deviated from those obtained using HPLC by 1.1+1.395 (n=26). In conclusion our SPE method is a rapid and reliable means of quality controlling 99m Tc-MIBI

  2. A reliable method for the quality control of 99mTc-MIBI prepared using fractionated cardiolite kits

    Energy Technology Data Exchange (ETDEWEB)

    Poot, M.T.; Varelis, P. [St George Hospital, Sydney, NSW (Australia). Department of Nuclear Medicine

    1998-06-01

    Full text: The reconstitution of fractionated Cardiolite kits with Na[{sup 99m}Tc]TcO{sub 4} eluted from a wet-column generator results in a preparation that contains elevated amounts of a polar radiochemical impurity, which is normally present in only trace amounts when such kits are reconstituted with eluate from a dry-column generator. We demonstrate, using HPLC, that this impurity causes a positive bias in several reported quality control methods (TLC, ITLC and SPE) for {sup 99m}Tc-MIBI, including that recommended by the manufacturer (TLC). A rapid procedure, based on a C18 solid phase extraction (SPE) cartridge, for measuring the radiochemical purity (RCP) of {sup 99m}Tc-MIBI samples was developed and compared with three other methods including HPLC. Over a RCP range of 49-98%, the values obtained using our SPE method deviated from those obtained using HPLC by 1.1+1.395 (n=26). In conclusion our SPE method is a rapid and reliable means of quality controlling {sup 99m}Tc-MIBI

  3. Detection of the involvement of salivary glands in autoimmune diseases of thyroid gland by using Ttc-99m MIBI

    Directory of Open Access Journals (Sweden)

    Deniz Söylemez ¹

    2017-03-01

    Full Text Available Aim: The aim of this study was to determine the involvement in the salivary glands of the patients with Graves’ Disease, Hashimoto Thyroiditis and controls by detecting the changes of Tc-99m Methoxyisobutylisonitrile (Tc-99m MIBI uptake. Material and Methods: The study was conducted between January 2008 and December 2009. 19 patients with Graves’ disease (6 men, 13 women, 28 Hashimoto Thyroiditis patients (5 men, 23 women and 11 euthyroid controls (4 men, 7 women were evaluated retrospectively. Uptake values of parotid and submandibular glands were calculated by drawing elliptical ROIs (region of interest and using the formula for uptake calculation. Result: In all three groups, in parotis glands, a statistical significant difference between Tc-99m MIBI uptake was not detected. The Tc-99m MIBI upateke values in submandibular glands were statistically different among patients with Graves’Disease, Hashimoto Thyroiditis, as well as in Control group (p<0.05. Conclusion: We concluded that the different uptake values of Tc-99m-MIBI in submandibular glands in Graves disease and Hashimoto thyroiditis as compared to the control group patient would be results of the histopathological features, such as autoimmunity, high mitochondria number and inflammatory reaction. [J Contemp Med 2017; 7(1.000: 67-73

  4. Effectiveness of Tc-99m MIBI scintigraphy in diagnosing lung cancer

    International Nuclear Information System (INIS)

    Tanaka, Shigebumi; Asao, Takayuki; Ubukata, Mikio; Sugiyama, Hiroyuki; Yajima, Yasumi; Takenoshita, Seiichi; Nagamachi, Yukio

    1997-01-01

    The use of Tc-99m hexakis 2-methoxy isobutyl isonitrile (MIBI) scintigraphy for quantitative diagnosis was examined. A total of 37 lesions from 31 patients with respiratory disease (19 lesions from 19 primary lung cancer patients, 8 lesions from 3 metastatic lung cancer patients and 10 lesions from benign lung disease patients) were examined. Positive results were seen in 89.4% of the primary lung cancer lesions, 50.0% of the metastatic lung cancer lesions, and 20.0% of the benign lung disease lesions. The positive rate of 77.7% for malignant lung cancer was significantly higher (P<0.01) than that for benign lung cancer. In particular, for lesions with a tumor diameter of 1.0 cm or more, the positive rate for malignant lung cancer lesions (95.2%) was significantly higher (P<0.001) than that for benign lung disease lesions (25.0%). These results thus indicate Tc-99m MIBI scintigraphy to be useful for qualitative diagnosis of lung peripheral coin lesions with a diameter of 1.0 cm or more. (author)

  5. Development of methods of labeling pentavalent DMSA with {sup 99m}Tc and {sup 188}Re; Desenvolvimento de metodos para marcacao de DMSA pentavalente com {sup 99m}Tc e {sup 188}Re

    Energy Technology Data Exchange (ETDEWEB)

    Brambilla, Tania de Paula, email: jtoniolo@ipen.br

    2009-07-01

    Technetium-99 m is the most useful radionuclide in diagnostic imaging procedures in Nuclear Medicine, more than 80 percent of radiopharmaceuticals are {sup 99m}Tc-labeled compounds. {sup 99m}Tc-DMSA(V) has been used for imaging of soft tissue, head and neck tumors. It shows a particularly high specificity for medullary thyroid carcinoma and bone metastases in a variety of cancers. Biodistribution studies of {sup 188}Re-DMSA(V) have shown that its general pharmacokinetic properties are similar to that of {sup 99m}Tc-DMSA(V), so this agent could be used for targeted radiotherapy of these tumors. The aim of this work is the development of methods of labeling DMSA(V) with {sup 99m}Tc and {sup 188}Re. {sup 99m}Tc-DMSA(V) can be prepared by two methods. One of them is the indirect one, through the use of a commercial kit of DMSA (III), by adjusting the pH from 2.5 to {approx} 8.5 with NaHCO{sub 3}. This method was evaluated and optimized presenting high labeling yields. The other method is the direct one, through the preparation of a lyophilised kit ready for labeling with {sup 99m}Tc, being the method of interest of this work, due to the easy of its clinical use. The most adequate formulation of the kit was: 1.71 mg of DMSA, 0.53 mg of SnCl{sub 2}.2H{sub 2}O and 0.83 mg of ascorbic acid (pH 9). Labeling yields higher than 95% were achieved labeling this kit with 1 to 2 m L of {sup 99m}Tc with activities up to 4736 MBq (128 mCi). The kit was stable up to 6 months and biodistribution studies confirmed the quality of the DMSA (V) labeled with {sup 99m}Tc using this kit. The reduction potential of Re is lower than the one for Tc, so the labeling conditions of {sup 188}Re-DMSA(V) are different from the ones used for {sup 99m}Tc- DMSA(V). {sup 188}Re-DMSA(V) is prepared in acid solution, that makes it possible to use the DMSA (III) commercial kit developed for labeling with {sup 99m}Tc, prepared in pH 2.5, for labeling with {sup 188}Re. Labeling yields higher than 95% were

  6. Precision measurement of the half-life of {sup 90m}Nb and {sup 99m}Tc

    Energy Technology Data Exchange (ETDEWEB)

    Kikunaga, H.; Fujisawa, H.; Ooe, K. [Osaka Univ., Toyonaka (Japan). Graduate School of Science] [and others

    2011-07-01

    We have produced {sup 90m}Nb and {sup 99m}Tc in the reactions of {sup nat}Zr(p, xn){sup 90m}Nb and {sup 100}Mo({gamma}, n){sup 99}Mo, followed by disintegration to {sup 99m}Tc, respectively, and measured the halflives of these nuclides by using a reference source method. In order to determine the short half-lives of {sup 90m}Nb precisely, an on-line gas-jet system has been employed. As a result, the half-lives of these nuclides were determined with good precision on the order of magnitude of 0.1%. (orig.)

  7. Quantification of 99mTc-MIBI lung uptake in myocardial SPECT studies

    International Nuclear Information System (INIS)

    Qu Wanying; Lu Zhenping; Zhou Ying; He Qin

    1996-01-01

    To assess the significance of 99m Tc-MIBI lung uptake during myocardial SPECT studies in the evaluation of left ventricular dysfunction. 42 control subjects and 65 patients with coronary artery disease (CAD) were investigated with 99m Tc-MIBI myocardial SPECT and radionuclide ventriculography (RNV) within 1 week. The lung-to-heart ratios (LHR) both at rest and exercise were calculated from the anterior projection of the SPECT image sets. The left ventricular ejection fraction (LVEF) was determined using RNV. In the control group, a significant decrease in LHR was observed during exercise (P<0.01). The CAD group showed significantly high LHR values both at rest and exercise. A negative correlation was observed between LHR values and LVEF at rest (r -0.6234, P<0.001) and exercise (r = -0.6113, P<0.001). LHR both at rest and exercise are significantly correlated with LVEF and may be useful in the evaluation of left ventricular function

  8. Radiation damage to mouse testis cells from [/sup 99m/Tc] pertechnetate

    International Nuclear Information System (INIS)

    Mian, T.A.; Suzuki, N.; Glenn, H.J.; Haynie, T.P.; Meistrich, M.L.

    1977-01-01

    The radiation dose and the biologic damage to mouse testis from intravenously administered [/sup 99m/Tc] pertechnetate were studied. The dose was measured for penetrating radiations from /sup 99m/Tc, using calibrated thermoluminescent dosimeters and calculations from the uptake of the nuclide in the testis, and was found to be 4.9 rads per mCi of 99 Tc. The biologic damage was measured by the decrease in the number of sperm heads in the testis, counted both by hemacytometer and by Coulter counter. In preliminary experiments using external gamma radiation from 137 Cs, the number of sperm heads reached a minimum 29 days after irradiation. Twenty-nine days after injection of 5.8 mCi of /sup 99m/Tc, which gives 28 rads to the testis, the number of sperm heads decreased to 70% of control. The biologic effect corresponds to that seen after 40 rads of gamma radiation from 137 Cs. The damage to mouse testis cells from internally administered /sup 99m/Tc as measured in an in vivo system appears to be at least as significant as that from external gamma irradiation, if not more so

  9. /sup 99m/Tc dextran: a new blood-pool-labeling agent for radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Henze, E.; Robinson, G.D.; Kuhl, D.E.; Schelbert, H.R.

    1982-01-01

    We have explored the possibility of imaging the cardiac blood pool with dextran (Dx) labeled with /sup 99m/Tc (Tc) after Sn2+ reduction. Stannous dextran (SnDx) kits were prepared in advance and labeling was performed by adding /sup 99m/Tc. The labeling efficiency was greater than 95%. /sup 99m/Tc dextran (TcDx) was highly stable both in vivo and in vitro. In seven dogs we compared the quality of blood-pool images obtained with TcDx of different molecular weights (4 X 10(4) . Dx-40; 5 X 10(5) . Dx-500; 2 X 10(6) . Dx-2000) and with /sup 99m/Tc red blood cells (TcRBC) labeled in vitro, and determined the organ distribution of this new agent by whole-body scanning and blood sampling. TcDx provided high-quality cardiac blood-pool images up to 60 min after injection. The heart-to-lung ratios averaged 3.7 for TcDx-40, 3.9 for TcDx-500, and 5.4 for TcRBC at 60 min. Whereas TcDx-40 showed a relatively rapid initial urinary excretion and TcDx-2000 was degraded rapidly, TcDx-500 demonstrated the best kinetics for blood-pool imaging. Thus, TcDx is a new radiopharmaceutical with high labeling efficiency and stability. It overcomes a number of the limitations of currently used blood-labeling agents and may become useful for blood-pool imaging in man

  10. Molecular imaging with {sup 99m}Tc-MIBI and molecular testing for mutations in differentiating benign from malignant follicular neoplasm: a prospective comparison

    Energy Technology Data Exchange (ETDEWEB)

    Giovanella, L.; Treglia, G.; Ceriani, L. [Oncology Institute of Southern Switzerland, Department of Nuclear Medicine and Thyroid Centre, Bellinzona (Switzerland); Campenni, A. [Policlinico Universitario, Istituto di Medicina Nucleare, Messina (Italy); Verburg, F.A. [RWTH University Hospital Aachen, Department of Nuclear Medicine, Aachen (Germany); Trimboli, P. [Oncology Institute of Southern Switzerland, Department of Nuclear Medicine and Thyroid Centre, Bellinzona (Switzerland); Ospedale Israelitico, Sezione di Endocrinologia e Diabetologia, Roma (Italy); Bongiovanni, M. [Centre Hopitalier Universitaire Vaudouise, Institut de Pathologie, Lausanne (Switzerland)

    2016-06-15

    To compare mutation analysis of cytology specimens and {sup 99m}Tc-MIBI thyroid scintigraphy for differentiating benign from malignant thyroid nodules in patients with a cytological reading of follicular neoplasm. Patients ≥18 years of age with a solitary hypofunctioning thyroid nodule (≥10 mm), normal thyrotropin and calcitonin levels, and a cytological diagnosis of follicular neoplasm were prospectively enrolled. Mutation analysis and {sup 99m}Tc-MIBI scintigraphy were performed and patients were subsequently operated on to confirm or exclude a malignant lesion. Mutations for KRAS, HRAS and NRAS and for BRAF and translocations of PAX8/PPARγ, RET/PTC1 and RET/PTC3 were investigated. Static thyroid scintigraphic images were acquired 10 and 60 min after intravenous injection of 200 MBq of {sup 99m}Tc-MIBI and visually assessed. Additionally, the MIBI washout index was calculated using a semiquantitative method. In our series, 26 % of nodules with a follicular pattern on cytology were malignant with a prevalence of follicular carcinomas. {sup 99m}Tc-MIBI scintigraphy was found to be significantly more accurate (positive likelihood ratio 4.56 for visual assessment and 12.35 for semiquantitative assessment) than mutation analysis (positive likelihood ratio 1.74). A negative {sup 99m}Tc-MIBI scan reliably excluded malignancy. In patients with a thyroid nodule cytologically diagnosed as a follicular proliferation, semiquantitative analysis of {sup 99m}Tc-MIBI scintigraphy should be the preferred method for differentiating benign from malignant nodules. It is superior to molecular testing for the presence of differentiated thyroid cancer-associated mutations in fine-needle aspiration cytology sample material. (orig.)

  11. Current Outlook for 99mTc Distribution Based on Electron Accelerator Production

    International Nuclear Information System (INIS)

    Benjamin L. Nelson; W. David Bence; John R. Snyder

    2007-01-01

    In 1999 a practical example illustrating the economical and reliable production of 99mTc from an accelerator was developed. It included the realistic costs involved in establishing and operating the accelerator facility and the distribution of the 99mTc to regions in Florida. However, the technology was never commercialized. Recent political and economic developments prompted this second look at accelerator produced 99mTc. The practicality of this system in 2007 dollars was established to account for inflation and current demand. The same distribution model and production schedule from the Global 1999 study were used. Numbers were found using current rates and costs where possible and indexed estimations when necessary. Though several of the costs increased significantly and the sale price remains at approximately 35 cents/mCi, the unit cost of 99mTc throughput only increased from 12.8 cents/mCi to 15.0 cents/mCi or approximately 17.2% from 1999 to 2007 thus continuing to be economically viable. This study provides ground work for creating business development models at additional locations within the U.S

  12. The new 99mTc myocardial perfusion imaging agents: 99mTc-sestamibi and 99mTc-teboroxime

    International Nuclear Information System (INIS)

    Berman, D.S.; Kiat, H.; Maddahi, J.

    1991-01-01

    The two new 99m (99mTc) labeled myocardial perfusion agents, 99mTc-Sestamibi and 99mTc-Teboroxime, are now available for routine clinical application. Both agents allow assessment of ejection fraction by the first-pass technique at rest or during exercise, thus providing additional information not available with thallium-201. 99mTc-Sestamibi has long myocardial residence time, as well as adequate myocardial extraction, providing images of higher count density and superior quality compared with thallium-201. 99mTc-Teboroxime has excellent myocardial uptake characteristics but is cleared very rapidly from the myocardium. Both tracers have shown results similar to those obtained with thallium-201 for detection of coronary artery disease and the assessment of defect reversibility. 99mTc-Sestamibi studies using the rest/stress imaging sequence can be accomplished in approximately 5 hours; studies using dual-isotope imaging (rest thallium-201 and stress 99mTc-Sestamibi injection) can be completed in 1 to 2 hours. Gated stress images can be performed with 99mTc-Sestamibi, providing simultaneous information of myocardial perfusion at stress and resting wall motion or thickening and allowing rapid differentiation of ischemic from infarcted tissue. Because of its slow myocardial clearance and absence of redistribution, 99mTc-Sestamibi allows uncoupling of the time of injection from the time of imaging and thus can be valuable in the evaluation of acute myocardial infarction and outcome of thrombolytic therapy. With 99mTc-Teboroxime, rapid serial studies are feasible. Pharmacologic stress and rest studies with 99mTc-Teboroxime single photon emission computed tomography potentially can be completed in under 30 minutes. 73 references

  13. Effect of verapamil on cellular uptake of Tc-99m MIBI and tetrofosmin on several cancer cells

    International Nuclear Information System (INIS)

    Kim, Dae Hyun; Yoo, Jung Ah; Bae, Jin Ho; Jeong, Shin Young; Suh, Myung Rang; Ahn, Byeong Cheol; Lee, Kyu Bo; Lee, Jae Tae

    2004-01-01

    Cellular uptake of 99 mTc-sestamibi (MIBI) and 99 mTc-tetrofosmin (TF) is low in cancer cells expressing multidrug resistance(MDR) by p-glycoprotein(Pgp) or multidrug related protein(MRP). Verapamil is known to increase cellular uptake of MIBI in MDR cancer cells, but is recently reported to have different effects on tracer uptake in certain cancer cells. This study was prepared to evaluate effects of verapamil on cellular uptake of MIBI and TF in several cancer cells. Cellular uptakes of Tc-99m MIBI and TF were measured in erythroleukemia K562 cell, breast cancer MCF7 cell, and human ovarian cancer SK-OV-3 cells, and data were compared with those of doxorubicin-resistant K562(Ad) cells. RT-PCR and Western blot analysis were used for the detection of mdr1 mRNA and Pgp expression, and to observe changes in isotypes of PKC enzyme. Effects of verapamil on MIBI and TF uptake were evaluated at different concentrations upto 200 μM at 1*10 6 cells/ m l at 37.deg.C. Radioactivity in supernatant and pellet was measured with gamma counter to calculate cellular uptake ratio. Toxicity of verapamil was measured with MTT assay. Cellular uptakes of MIBI and TF were increased by time in four cancer cells studied. Co-incubation with verapamil resulted in an increase in uptake of MIBI and TF in K562(Adr) cell at a concentration of 100 μM and the maximal increase at 50 μM was 10-times to baseline. In contrast, uptakes of MIBI and TF in K562, MCF7m SK-OV3 cells were decreased with verapamil treatment at a concentration over 1 μM. With a concentration of 200 μM verapamil, respectively. Cellular uptakes of MIBI and TF in MCF7 and SK-OV-3 cells were not changed with 10μM, but were also decreased with verapamil higher than 10μM, resulting 40% and 5% of baseline at 50 μM. MTT assay of four cells revealed that K562, MCF7, SK-OV3 were not damaged with verapamil at 200 μM. Although verapamil increases uptake of MIBI and TF in MDR cancer cells, cellular uptakes were further decreased

  14. {sup 99m}Tc-(V)DMSA scintimammography in the assessment of breast lesions: comparative study with {sup 99m}Tc-MIBI

    Energy Technology Data Exchange (ETDEWEB)

    Papantoniou, V.; Papadaki, E.; Valotassiou, V.; Stipsanelli, A.; Zerva, C. [Dept. of Nuclear Medicine, Alexandra University Hospital, Athens (Greece); Christodoulidou, J.; Pampouras, G. [Dept. of Radiology, Alexandra University Hospital, Athens (Greece); Louvrou, A.; Lazaris, D.; Keramopoulos, A.; Michalas, S. [Dept. of Obstetrics and Gynaecology, Alexandra University Hospital, Athens (Greece); Sotiropoulou, M. [Dept. of Pathology, Alexandra University Hospital, Athens (Greece)

    2001-07-01

    The purpose of this study was to evaluate and compare the diagnostic accuracy of pentavalent technetium-99m dimercaptosuccinic acid [{sup 99m}Tc-(V)DMSA] and {sup 99m}Tc-methoxyisobutylisonitrile (MIBI) in the detection of primary breast cancer and metastatic lymph node involvement, and in the clarification of cases with indeterminate mammograms. Forty-one women (mean age{+-}SD 55{+-}7 years) referred for a suspicious breast lesion on physical examination and/or an abnormal mammogram underwent MIBI and (V)DMSA scintimammography (SMM) at separate sessions (48-h interval). Lateral prone and anterior supine images were obtained at 10 and 60 min after administration of 740-925 MBq of each tracer, in the arm contralateral to the breast lesion. The ipsilateral axillary region was also included in the field of view. The results of SMM and mammography were compared with histological findings. Breast cancer was histologically confirmed in 26 patients (mean diameter{+-}SD 2.87{+-}1.5 cm). Benign lesions were found in 15 patients (mean diameter{+-}SD 2.04{+-}2.7 cm). Mammography was definitely positive in 23/26 patients with breast cancer and indeterminate in 3/26 (sensitivity 88.4%). In benign lesions, mammography was true negative in 5/15 cases and indeterminate in 10/15 (specificity 33.3%). Both MIBI and (V)DMSA SMM detected 23/26 breast cancers (sensitivity 88.4%) and were true negative in 14/15 (specificity 93.3%). T/B ratios for breast cancer in MIBI and (V)DMSA scans were similar, and significantly higher than for benign lesions. MIBI correctly diagnosed 12/13 and (V)DMSA 11/13 cases in which the findings of mammography were indeterminate. In addition, (V)DMSA detected seven of eight cases of in situ ductal carcinoma (DCIS) associated with infiltrating carcinomas, while MIBI detected only two of these eight cases. (V)DSMA was also diffusely concentrated in benign lesions complicated by epithelial hyperplasia. Metastatic lymph node involvement was successfully imaged in

  15. 99Tcm-MIBI imaging with liposomal prostaglandin E1 infusion to detect viable myocardium in post-myocardial infarction patients

    International Nuclear Information System (INIS)

    Zheng Yong; Cai Hongbin; Miao Weibing; Lin Jun; Pan Runyang; Lin Haoxue

    2007-01-01

    Objective: The pharmacological efficiencies of liposomal prostaglandin E 1 (Lipo-PGE 1 ) infusion and nitrate infusion on 99 Tc m -methoxyisobutylisonitrile (MIBI) imaging detection of viable myocardium in post-myocardial infarction (MI) patients were compared in the current study. Methods: Thirty-two patients with MI underwent 99 Tc m -MIBI imaging at rest, nitrate infusion and Lipo-PGE 1 infusion respectively. The semi-quantitative analysis of 99 Tc m -MIBI imaging was carried out in 16 segments over each left ventricle. Results: Abnormal 99 Tc m -MIBI distribution in 216 segments (42.2%) at rest, 178 segments (34.8%) at nitrate infusion, and 184 segments (35.9%) at Lipo-PGE 1 infusion were identified. Among the 216 abnormal segments at rest, 89 (41.2%) and 81 (37.5%) were found improved after nitrate infusion and Lipo-PGE 1 infusion respectively. Detecting viable myocardium with Lipo-PGE 1 infusion imaging was accordant with that of nitrate infusion imaging in 89.8% of the cases. The mean uptake scores of abnormal segments at rest, nitrate infusion, and Lipo-PGE 1 infusion were 15.3 ± 3.3, 10.5 ± 1.4 (P 1 infusion imaging can be used for detection of viable myocardium in patients with MI. (authors)

  16. Phenolic aminocarboxylate chelates of sup(99m)Tc as hepatobiliary agents

    Energy Technology Data Exchange (ETDEWEB)

    Hunt, F.C.; Maddalena, D.J.; Wilson, J.G.; Bautovich, G.J.

    1986-01-01

    A series of alkyl- and halogen-substituted derivatives of ethylenediamine di(omicron-hydroxyphenylacetic acid) (EDDHA) and N,N'-bis(2-hydroxybenzyl) ethylenediamine N,N'-diacetic acid (HBED) were complexed with sup(99m)Tc and their biodistribution was determined in rats. All complexes displayed substantial hepatobiliary excretion; of each series, sup(99m)Tc-Br-EDDHA and sup(99m)Tc-di-Cl-HBED had the maximum amount in the gastrointestinal tract. Scintigraphic studies of sup(99m)Tc-Cl-EDDHA in dogs revealed prompt imaging of the liver followed by imaging of the gall bladder as the complex was excreted into the bile.

  17. Phenolic aminocarboxylate chelates of sup(99m)Tc as hepatobiliary agents

    International Nuclear Information System (INIS)

    Hunt, F.C.; Maddalena, D.J.; Wilson, J.G.; Bautovich, G.J.

    1986-01-01

    A series of alkyl- and halogen-substituted derivatives of ethylenediamine di[omicron-hydroxyphenylacetic acid] (EDDHA) and N,N'-bis[2-hydroxybenzyl] ethylenediamine N,N'-diacetic acid (HBED) were complexed with sup(99m)Tc and their biodistribution was determined in rats. All complexes displayed substantial hepatobiliary excretion; of each series, sup(99m)Tc-Br-EDDHA and sup(99m)Tc-di-Cl-HBED had the maximum amount in the gastrointestinal tract. Scintigraphic studies of sup(99m)Tc-Cl-EDDHA in dogs revealed prompt imaging of the liver followed by imaging of the gall bladder as the complex was excreted into the bile. (author)

  18. Synthesis of Cu[MIBI]4Cl to prepare 99m Tc [MIBI]6+ as a myocardial perfusion agent

    International Nuclear Information System (INIS)

    Ramirez G, L.

    1994-01-01

    2-Methoxyisobutylisonitrile (MIBI) is a key starting material in the preparation of technetium-99m hexakis (2-methoxyisobutylisonitrile). This cationic complex has been reported to be clinically useful as myocardial perfusion agent. In this work, we designed an improved synthetic method to prepare 2-methoxyisobutylisonitrile in a two step synthesis with an overall yield of 52.9 % , on the basis of 2-methoxyisobutylamine is a primary amine which, when is heated with a mixture of chloroform and alcoholic potash, produces an isonitrile. Its spectroscopic properties as well as the preparation of its copper and technetium-99m complexes are also presented. (Author)

  19. The value of Tc-99m MIBI SPECT during isosorbide dinitrate infusion in assessment of viable myocardium in patients with myocardial infarction

    International Nuclear Information System (INIS)

    Li Shengting; Liu Xiujie; Lu Zongliang

    1996-01-01

    Tc-99m MIBI myocardial SPECT has shown promise for evaluation of coronary artery disease. But its role in predicting myocardial viability is still under investigation. The purpose of this study was to evaluate the value of Tc-99m MIBI myocardial SPECT during isosorbide dinitrate (ISDN) infusion in the assessment of myocardial viability. Thirty-seven patients with previous myocardial infarction (the infarct age ranged from ≤ 30 days to 900 days) were studied, of them 13 patients had Tc-99m MIBI studies before and after coronary artery bypass grafting (CABG). The results showed that out of 134 segments with hypoperfusion at resting SPECT, 56 segments (41.8%) had an increase in Tc-99m MIBI uptake during ISDN infusion. Among them, 17 segments (30.4%) were normalized, 6 segments (10.7%) were significantly improved and 33 segments (58.9%) were improved. The degree of improvement in perfusion was related to the age of the myocardial infarction. In 13 patients with CABG, of 31 segments with improvement in perfusion post CABG, 25 segments (80.6%) showed perfusion improvement during ISDN infusion, and of 28 segments with improved wall motion post CABG, 23 segments (82.1%) showed improvement in perfusion during ISDN infusion. Tc-99m MIBI SPECT during ISDN infusion may therefore be a useful approach for assessing myocardial viability. (author)

  20. Production optimization of {sup 99}Mo/{sup 99m}Tc zirconium molybate gel generators at semi-automatic device: DISIGEG

    Energy Technology Data Exchange (ETDEWEB)

    Monroy-Guzman, F., E-mail: fabiola.monroy@inin.gob.mx [Instituto Nacional de Investigaciones Nucleares, Carretera Mexico-Toluca S/N, La Marquesa, Ocoyoacac, 52750, Estado de Mexico (Mexico); Rivero Gutierrez, T., E-mail: tonatiuh.rivero@inin.gob.mx [Instituto Nacional de Investigaciones Nucleares, Carretera Mexico-Toluca S/N, La Marquesa, Ocoyoacac, 52750, Estado de Mexico (Mexico); Lopez Malpica, I.Z.; Hernandez Cortes, S.; Rojas Nava, P.; Vazquez Maldonado, J.C. [Instituto Nacional de Investigaciones Nucleares, Carretera Mexico-Toluca S/N, La Marquesa, Ocoyoacac, 52750, Estado de Mexico (Mexico); Vazquez, A. [Instituto Mexicano del Petroleo, Eje Central Norte Lazaro Cardenas 152, Col. San Bartolo Atepehuacan, 07730, Mexico D.F. (Mexico)

    2012-01-15

    DISIGEG is a synthesis installation of zirconium {sup 99}Mo-molybdate gels for {sup 99}Mo/{sup 99m}Tc generator production, which has been designed, built and installed at the ININ. The device consists of a synthesis reactor and five systems controlled via keyboard: (1) raw material access, (2) chemical air stirring, (3) gel dried by air and infrared heating, (4) moisture removal and (5) gel extraction. DISIGEG operation is described and dried condition effects of zirconium {sup 99}Mo- molybdate gels on {sup 99}Mo/{sup 99m}Tc generator performance were evaluated as well as some physical-chemical properties of these gels. The results reveal that temperature, time and air flow applied during the drying process directly affects zirconium {sup 99}Mo-molybdate gel generator performance. All gels prepared have a similar chemical structure probably constituted by three-dimensional network, based on zirconium pentagonal bipyramids and molybdenum octahedral. Basic structural variations cause a change in gel porosity and permeability, favouring or inhibiting {sup 99m}TcO{sub 4}{sup -} diffusion into the matrix. The {sup 99m}TcO{sub 4}{sup -} eluates produced by {sup 99}Mo/{sup 99m}Tc zirconium {sup 99}Mo-molybdate gel generators prepared in DISIGEG, air dried at 80 Degree-Sign C for 5 h and using an air flow of 90 mm, satisfied all the Pharmacopoeias regulations: {sup 99m}Tc yield between 70-75%, {sup 99}Mo breakthrough less than 3 Multiplication-Sign 10{sup -3}%, radiochemical purities about 97% sterile and pyrogen-free eluates with a pH of 6. - Highlights: Black-Right-Pointing-Pointer {sup 99}Mo/{sup 99m}Tc generators based on {sup 99}Mo-molybdate gels were synthesized at a semi-automatic device. Black-Right-Pointing-Pointer Generator performances depend on synthesis conditions of the zirconium {sup 99}Mo-molybdate gel. Black-Right-Pointing-Pointer {sup 99m}TcO{sub 4}{sup -} diffusion and yield into generator depends on gel porosity and permeability. Black

  1. Milking technique of sup(99m)Tc generators and labeling efficiencies

    International Nuclear Information System (INIS)

    Salehi, N.; Guignard, P.A.

    1985-01-01

    Increased levels of 99 Tc in generator produced sup(99m)Tc have an adverse effect on the labelling efficiency of red blood cells and human serum albumin. A two-step milking technique in which the first 1-2 ml of eluate is discarded has been found to produce higher and more constant labelling efficiency of lymphocytes and platelets than a one-step procedure. Binding efficiency of platelet-rich plasma and lymphocytes with sup(99m)Tc is greater in the two-step technique. High activity concentration in the eluate for critical labelling is between 1.5-3 ml. (U.K.)

  2. Role of 99MTc-DTPA renal scintigraphy using gates protocol with extended acquisition time in evaluation of the function of pre-operative donor kidneys and post-operative remaining kidney

    International Nuclear Information System (INIS)

    Trinh Thi Minh Chau; Nguyen Xuan Canlh; Le Huu tam; Truong Quang Xuan

    2004-01-01

    Introduction: Radionuclide Methods have been extensively used in kidney transplantation. This non-invasive technique provides quantitative analysis of total and individual renal function as well as assessment of urinary outflow tract. Aim of this study was to evaluate renal function of potential kidney-donors and follow up post-nephrectomy kidney-donors by 99mTc-DTPA renal scintigraphy using Gates protocol with extended acquisition. MATERIALS AND Methods: This study included 72 living kidney donors. In addition to routine laboratory and radiological evaluations, a 99mTc-DTPA dynamic renal scintigraphy was acquired 15 second per frame for 30 minutes. Glomerular filtration rate (GFR) was calculated based on Gates protocol. Urinary outflow tract was assayed by renogram generated and consecutive dynamic renal images of up to 30 minute. Renal scintigraphy was also performed in follow-up of 37 post-nephrectomy kidney donors. Results 6 of 72 (8.3%) living related donors were excluded from nephrectomy due to reduced GFR of either total or individual kidney. One of 6 excluded donors had one non-functional kidney. No donors have shown urinary tract obstruction. In 66 kidney donors who were indicated nephrectomy, pre-nephrectomy mean total GFR, calculated by Gates method, was 108 mi/minute that was significantly higher than GFR result of 94 mi/minute by Cockcroft and Gault prediction equation (p 0.05). These results are not significant, indicative of functional compensation occuring after unilateral nephrectomy. Conclusion: Tc-99m DTPA dynamic renal scintigraphy using Gates protocol with extended acquisition time is a valuable simple radionuclide technique which is able to assess total and individual renal function and urinary outflow tract. This technique should be used as an integral part of the pre-operative evaluation contributing to the choice of nephrectomy side in potential kidney donors and as follow-up of post-operative remaining kidney. (authors)

  3. Lung scintigraphy with Tc-99m-MIBI in diagnosis of active tuberculosis

    International Nuclear Information System (INIS)

    Raziei, G.; Fotouhi, F.; Masjedi, M.R.; Neshandar, E.

    2002-01-01

    Tuberculosis is highly contagious infection and one of the most important health problems in the world today, particularly in our country. Routine diagnostic procedures are sometimes unable to differentiated active from inactive cases particularly in elderly. Children, immunomedics patients, Chronic cases with recurrent actuate infection and in the patients unable to provide sputum for microbiological studies. Several radiopharmaceuticals have been used in the evaluation of active pulmonary TB. In this study Tc 99 m-MIBI lung scan was performed using a single head ADAC gamma camera. 62 patients including 34 APTB 915 male and 19 female) and 28 IPTB 99 male and 19 female) underwent six minutes anterior and posterior chest images 20 and minutes after injection of 10 mCi (370 MBq) of Tc 99 m-MIBI. Visual grading was generated by comparing uptake of lesion with neck soft tissue (sternoleidomastoid muscle) and myocardium. For semiquantitative analysis, regions of interest were draw over the lesion (L), non lesion (NL) and neck soft tissue (SCM) and mean count value of ROIs as well as L/NL, L/SCM values were obtained. Results: From 34 patients with APTB, 4 PTS had normal lung uptake (11.7%), 14 PTs+(41, 2%), 14 PTs++41.2%) and 2 PTS +++ (5.9%), therefore 30 PTs of APTB were positive in scintigraphy (88.2%). From 28 patients with IPTB 21 PTs had normal lung uptake (75%), 6 PTs+ (21.4%) and one PT ++ (3.5%). In the semi quantitative study L/NL ratio is calculated for + about 1.35 +/-0.15 and below from this range is considered with normal limit. The sensitivity, specificity, accuracy, PPV and NPV were 88.2% 75%, 82.2%, 81.1% and 84% respectively. From 100 CXR lesion in APTB, 60 had compatible positive scan and from 86 CXR lesions in IPTB 9 had compatible positive scan, where as incompatible positive findings were 12 and 2 respectively. This study indicates Tc 99 m - MIBI lung scan can be used as a reliable complementary study in diagnosis of APTB and differentiating from

  4. The significance of a dipyridamole induced [sup 99m]Tc-MIBI perfusion abnormality on single photon emission tomography: A quantiative validation with labelled water and positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Rechavia, E.; Galassi, A.R.; Araujo, L.I.; Halson, P.; Lammertsma, A.; Jones, T.; Lavender, J.P.; Maseri, A. (Royal Postgraduate Medical School, London (United Kingdom). Nuclear Medicine Dept. Medical Research Council, London (United Kingdom). Cyclotron Unit Medical Research Council, London (United Kingdom). Cardiovascular Unit)

    1992-12-01

    To relate [sup 99m]Tc-MIBI uptake to regional myocardial blood flow (rMBF), [sup 99m]Tc-MIBI SPET and H[sub 2] [sup 15]O PET scans were obtained at rest and after dipyridamole infusion in six patients with single vessel coronary artery disease. [sup 99m]Tc-MIBI-H[sub 2] [sup 15]O data sets were created for each segment perfused by the stenotic vessel and for a normal reference area, assigning regions on the SPET tomograms to comparable regions on the PET by similar transaxial image reconstructions. All patients demonstrated post-dipyridamole [sup 99m]Tc-MIBI perfusion defects in the territories supplied by the stenotic arteries; Resting rMBF in these regions was slightly lower than that in the normal areas. A 43% [+-] 14% reduction in [sup 99m]Tc-MIBI activity in the area at risk was coupled with on average a 60% [+-] 9% reduction in post-dipyridamole rMBF compared with control regions. Thus, SPET assessment of [sup 99m]Tc-MIBI uptake tends to underestimate the perfusion contrast between areas with normal and areas with low coronary vasodilatory reserve when compared to PET. However, these findings may still not affect the clinical usefulness of [sup 99m]Tc-MIBI and more extensive studies are required to confirm these results in the clinical environment (orig./MG).

  5. Alcoholic hepatitis with negligible sup(99m)Tc uptake and transient elevation of serum alpha-fetoprotein

    International Nuclear Information System (INIS)

    Hoshino, Hirosuke; Okumura, Makoto; Shimizu, Masanori; Eimoto, Tadaaki

    1981-01-01

    A 35 year old male with typical alcoholic hepatitis presented almost negligible uptake of sup(99m)Tc on the liver scan. Electron microscopic findings disclosing decreased number of Kupffer cells and impaired blood flow in the sinusoids may elucidate extremely diminshed uptake of isotope by the liver. Transient elevation of serum α-fetoprotein up to 3200 ng/ml observed during the active stage may indicate a regeneration process of hepatic necrosis occurred following the acute alcoholic hepatitis. (author)

  6. Benchmark experiment for the cross section of the 100Mo(p,2n)99mTc and 100Mo(p,pn)99Mo reactions

    Science.gov (United States)

    Takács, S.; Ditrói, F.; Aikawa, M.; Haba, H.; Otuka, N.

    2016-05-01

    As nuclear medicine community has shown an increasing interest in accelerator produced 99mTc radionuclide, the possible alternative direct production routes for producing 99mTc were investigated intensively. One of these accelerator production routes is based on the 100Mo(p,2n)99mTc reaction. The cross section of this nuclear reaction was studied by several laboratories earlier but the available data-sets are not in good agreement. For large scale accelerator production of 99mTc based on the 100Mo(p,2n)99mTc reaction, a well-defined excitation function is required to optimise the production process effectively. One of our recent publications pointed out that most of the available experimental excitation functions for the 100Mo(p,2n)99mTc reaction have the same general shape while their amplitudes are different. To confirm the proper amplitude of the excitation function, results of three independent experiments were presented (Takács et al., 2015). In this work we present results of a thick target count rate measurement of the Eγ = 140.5 keV gamma-line from molybdenum irradiated by Ep = 17.9 MeV proton beam, as an integral benchmark experiment, to prove the cross section data reported for the 100Mo(p,2n)99mTc and 100Mo(p,pn)99Mo reactions in Takács et al. (2015).

  7. Comparative uptake of 67Ga and /sup 99m/Tc MDP in rabbits with a benign noninfected bone lesion (fracture)

    International Nuclear Information System (INIS)

    Bushberg, J.T.; Hoffer, P.B.; Schreiber, G.J.; Lawson, A.J.; Lawson, J.P.; Lord, P.

    1985-01-01

    Mid-shaft fractures of the radius and ulna were produced in 3 to 4 kg New Zealand white rabbits and quantitative uptake of /sup 99m/Tc MDP and 67 Ga determined at 11, 18, 25, 32, 51, and 78 days following fracture. Two hundred microCi of 67 Ga was administered 24 hours prior to sacrifice and 1.5 mCi /sup 99m/Tc MDP 2 hours prior to sacrifice. Specific activity ratios (SARs) were determined between fracture and control sides for bone, muscle and skin. SARs for bone were surprisingly similar for /sup 99m/Tc MDP and 67 Ga, reaching peak values of 6.07 +/- 0.64 (/sup 99m/Tc 18 days); 6.58 +/- 0.90 ( 67 Ga 32 days), subsequently decreasing to minimum values at 78 days postfracture (/sup 99m/Tc MDP 2.25 +/- 0.14; 67 Ga 2.18 +/- 0.08). There was no statistically significant difference in SAR for /sup 99m/Tc MDP vs. 67 Ga in bone at any time after fracture. Whole sections of limb were resected on selected animals and activity ratios determined for these sections as a function of the contribution of activity from the various tissues in the volume of interest. Total activity ratios of 67 Ga were lower than bone SARs as a result of the contribution of activity from muscle and skin. Thus, the apparent lower activity ratios noted on 67 Ga images compared with /sup 99m/Tc MDP images in this fracture model were not due to differences in bone SARs but rather due to the higher soft tissue background activity contribution in the 67 Ga images

  8. MIBI-SPECT in hypofunctioning thyroid nodules for detection of thyroid carcinoma; MIBI-SPECT bei kalten Knoten zur Schilddruesenkarzinomdetektion

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, M.; Schicha, H. [Universitaetsklinikum Koeln (Germany). Klinik und Poliklinik fuer Nuklearmedizin

    2010-12-15

    The clinical usefulness of Tc-99m-MIBI in hypofunctioning thyroid nodules for detection of thyroid carcinoma is presented. Tc-99m-MIBI is a lipophilic cation and a non-specific radiopharmaceutical for tumour imaging. It has become an important imaging technique for the assessment of hypofunctioning thyroid nodules because of its high negative predictive value excluding malignant thyroid tumours. After injection of Tc-99m-MIBI either a single-phase protocol with late planar and SPECT images about 1-2 h post injection or a double-phase protocol with early (about 15-30 min p.i.) and late images (about 2 h p.i.) were reported. Findings include a reduced, an isointense or an increased Tc-99m-MIBI accumulation in the thyroid nodule in comparison to the paranodular thyroid tissue and in comparison to pertechnetate thyroid scintigraphy. A 'Match' between pertechnetate and Tc-99m-MIBI scintigraphy is a concordantly decreased uptake in the thyroid nodule in comparison to the normal thyroid gland. This finding has a negative predictive value of >97% to exclude differentiated thyroid cancer. A definite 'Mismatch' means a cold thyroid nodule on pertechnetate scintigraphy and an increased uptake of Tc-99m-MIBI in comparison to the MIBI-uptake of the paranodular thyroid tissue. The positive predictive value of this finding for malignancy varies between studies and is in the range of <10-65% (Cologne data: 19%) depending on the prevalence of malignant thyroid tumours in the patient population studied. An isointense uptake was not associated with thyroid malignancy according to 'Cologne' data. Further studies are desirable for better characterization of the method. (orig.)

  9. Dual-phase 99mTc-MIBI scintigraphy with delayed neck and thorax SPECT/CT and bone scintigraphy in patients with primary hyperparathyroidism. Correlation with clinical or pathological variables

    International Nuclear Information System (INIS)

    Qiu, Zhongling; Shen, Chentian; Zhu, Ruisen; Luo, Quanyong; Wu, Bo

    2014-01-01

    The purpose of this study was to assess the relationship between 99m Tc-MIBI and 99m Tc-MDP bone scintigraphy and clinical or pathological variables, including preoperative serum PTH levels and tumor diameter, in patients with newly diagnosed PHPT. Dual phase 99m Tc-MIBI planar scintigraphy was performed in 244 patients with PHPT. Of these patients, 155 underwent 99m Tc-MDP bone scintigraphy to detect bone changes before parathyroidectomy. Factors influencing 99m Tc-MIBI scintigraphy and 99m Tc-MDP bone scintigraphy detection rate were assessed using univariate and multivariate logistic regression analysis; optimal cutoff values for predicting positive 99m Tc-MIBI and 99m Tc-MDP bone scintigraphy were evaluated using ROC analysis. Among 244 patients, 174 (71.31%) patients with 181 foci had a positive 99m Tc-MIBI planar scintigraphy; delayed neck and thorax SPECT/CT could identify and locate the 99m Tc-MIBI lesions but could not find more lesions than planar scintigraphy. 70 (28.69%) patients had a negative 99m Tc-MIBI planar scintigraphy. Tumor diameter, serum PTH level and symptoms were statistically significant predictive factors in predicting positive 9m Tc-MIBI scintigraphy both univariate and multivariate logistic regression analyses. The optimal thresholds for tumor diameter and serum PTH by ROC analysis were 1.03 cm and 127.60 ng/L, respectively. Among 155 patients with bone scintigraphy, 99m Tc-MDP bone scintigraphy showed positive finding in 80 (51.61%) patients and negative finding in 75 patients. Univariate logistic regression analysis showed that patient age, sex, tumor diameter and PTH level (≥150 ng/L) were statistically significant in predicting positive 99m Tc-MDP bone scintigraphy. Multivariate logistic regression analysis showed both tumor diameter and PTH ≥150 ng/L were statistically significant in predicting positive 99m Tc-MDP bone scintigraphy. The optimal thresholds for tumor diameter and serum PTH by ROC analysis were 1.96 cm and 163

  10. Alternative chromatographic system for the quality control of lipophilic technetium-99m radiopharmaceuticals such as [99mTc(MIBI6]+

    Directory of Open Access Journals (Sweden)

    D.P. Faria

    2015-01-01

    Full Text Available Knowledge of the radiochemical purity of radiopharmaceuticals is mandatory and can be evaluated by several methods and techniques. Planar chromatography is the technique normally employed in nuclear medicine since it is simple, rapid and usually of low cost. There is no standard system for the chromatographic technique, but price, separation efficiency and short time for execution must be considered. We have studied an alternative system using common chromatographic stationary phase and alcohol or alcohol:chloroform mixtures as the mobile phase, using the lipophilic radiopharmaceutical [99mTc(MIBI6]+ as a model. Whatman 1 modified phase paper and absolute ethanol, Whatman 1 paper and methanol:chloroform (25:75, Whatman 3MM paper and ethanol:chloroform (25:75, and the more expensive ITLC-SG and 1-propanol:chloroform (10:90 were suitable systems for the direct determination of radiochemical purity of [99mTc(MIBI6]+ since impurities such as 99mTc-reduced-hydrolyzed (RH, 99mTcO4 - and [99mTc(cysteine2]- complex were completely separated from the radiopharmaceutical, which moved toward the front of chromatographic systems while impurities were retained at the origin. The time required for analysis was 4 to 15 min, which is appropriate for nuclear medicine routines.

  11. 99Tcm-MIBI and 18F-FDG DISA imaging in the evaluation of CABG combined with autologous bone marrow mononuclear cell transplantation in patients with myocardial infarction

    International Nuclear Information System (INIS)

    Zhang Fuqiang; Chen Xianying; Zhang Guoxu; Wang Zhiguo; Ma Dongchu; Wang Huishan

    2009-01-01

    Objective: Autologous bone marrow mononuclear cell transplantation is a treatment modality under investigation for severe coronary heart disease. Its beneficial effects on ventricular function, myocardial perfusion and metabolism remain to be evaluated. The present study proposed a 18 F-fluorodeoxyglucose (FDG) and 99 Tc m -methoxyisobutylisinitrile (MIBI) dual-isotope simultaneous acquisition (DISA) imaging technique to assess the effects of coronary artery bypass grafting (CABG) combined with autologous bone marrow mononuclear cell transplantation in patients with old myocardial infarction (OMI). Methods: Twenty patients with OMI, whose diagnosis was confirmed with angiography. were divided into a convention. al CABG group (group A, n=11) and CABG+ autologous bone marrow mononuclear cell transplantation group (group B, n=9). All subjects underwent gated cardiac DISA tomography at one week preoperatively and four months postoperatively. The segmental myocardial uptake of the tracers was scored as 3, 2, 1 and 0. Paired-samples t test was used to compare data of the two groups. Results In group A, there were 52 perfusion/metabolism mismatched segments, 99 Tc m -MIBI and 18 F-FDG uptake scores of these segments in-creased from preoperatively 1.48 ± 0.75( 99 Tc m -MIBI)and 1.90 ± 0.75( 18 F-FDG) to postoperatively 1.75 ± 0.68 and 2.13 ± 0.74 (t=3.25 and 2.37, both P 0.05). However, in group B, there was significant increase of the myocardial uptake scores both in mismatched segments and matched segments. In the 45 mismatched segments of this group,preoperative and postoperative 99 Tc m -MIBI/ 18 F-FDG uptake scores were 1.24 ± 0.68/1.71 ± 0.76 and 1.53 ± 0.66/2.00 ± 0.64, respectively (t=2.93 and 2.56. both P 99 Tc m -MIBI/ 18 F-FDG uptake scores were 0.94 ± 0.75/1.50 ± 0.74 and 1.22 ± 0.76/1.78 ± 0.64. respectively (t=2.71 and 3.37. both P 0.05). Conclusions: CABG combined with autologous bone marrow mononuclear cell transplantation may improve myocardial

  12. 99m-Tc DMSA scintigraphy and color/power doppler sonography for children pyelonephritis diagnosis and follow-up

    International Nuclear Information System (INIS)

    Hitzel, A.; Manrique, A.; Gardin, I.; Vera, P.; Hitzel, A.; Dacher, J.N.; Manrique, A.; Menard, J.F.; Gardin, I.; Vera, P.; Dacher, J.N.; Liard, A.; Menard, J.F.

    2004-01-01

    Early diagnosis of acute pyelonephritis is essential to avoid scarring development. This study was performed to evaluate capabilities of color/doppler sonography to detect pyelonephritis and to predict scarring when compared with 99m Tc-DMSA scintigraphy. Fifty-seven children were evaluated during pyelonephritis: biology (CRP, creatinine, blood formula), color/power doppler sonography and 99m Tc-DMSA scintigraphy (DMSA1). 7 ± 2 months later, follow-up consisted in biological tests and a 99m 'Tc-DMSA scintigraphy (DMSA2). During pyelonephritis, body temperature, CRP value and neutrophil counts were significantly higher in patients with an abnormal DMSA1 but not in patients with abnormal doppler sonography. When compared with DMSA1, doppler sonography sensitivity and specificity were 80% and 81% respectively. DMSA1 and doppler sonography were concordant in 86% of children with a pyelonephritis. At follow-up, all clinical et biological parameters were normalized. DMSA2 was abnormal in 51% of children. When compared with DMSA2, positive and negative predictive values for scarring of doppler sonography were 57% and 75% respectively. DMSA 1, positive and negative predictive values for scarring were 62% and 100%. In conclusion, color/power doppler sonography is a reliable tool for pyelonephritis diagnosis, but its predictive value for scarring is poor. Negative predictive value of DMSA scintigraphy is excellent. (author)

  13. Production of $^{99}$?? and $^{99m}$Tc in the $^{100}$Mo($\\gamma, n$) Photonuclear Reaction at the Electron Accelerator - MT-25 Microtron

    CERN Document Server

    Sabelnikov, A V; Gustova, M V; Dmitriev, S N

    2004-01-01

    $^{99}$Mo was obtained in the $^{100}$Mo($\\gamma, n$) reaction at the electron accelerator - MT-25 microtron of the LNR. A foil of $^{\\rm nat}$Mo(9.6{\\%} $^{100}$Mo) and $^{100}$MoO$_{3}$ powder (100{\\%} ^{100}$Mo) were used as targets. The $^{99}$Mo radiation yield under experimental conditions amounted to 3.2 kBq/$\\mu $A$\\cdot $h$\\cdot $mg of $^{100}$Mo. The $^{99m}$Tc isolation from the target material and other radioactive impurities was realized by means of ion exchange. A possibility of use of the $^{99}$Mo/$^{99m}$Tc generator based on molybdenumcarbonyl was investigated. The radioactive impurity content in the final $^{99m}$Tc preparations did not exceed 10$^{-5}$ Bq/Bq.

  14. Application of 99mTc-MIBI for diagnostic evaluation of multiple myeloma and lymphoma

    International Nuclear Information System (INIS)

    Kostadinova, I.; Garcheva, M.; Petrov, T.

    1995-01-01

    An attempt is made to determine the stage of multiple myeloma (MM), Hodgkin lymphoma (HL) and non-Hodgkin lymphoma (NHL) after applying 99 mTc-MIBI, as well as to proof the residual vital tissue after chemo- and radiotherapy. 15 patients with these diseases and 3 controls are examined. An increased tracer uptake was found at 7 of the patients along the bones (in MM) or focal intake at typical places (in HL and NHL) as a sign of an active disease. In comparison with X-ray and bone scintigraphy, the whole body examination with 99m Tc-MIBI allows visualization of more pathological sites. The preliminary results show that more patients with MM, HL and NHL can be examined in order to determine activity and stage of the disease and to differentiate between active and fibrous tissues after chemo and radio therapy. 6 refs., 2 figs. (author)

  15. Electrolytic preparation of sup(99m)Tc human serum albumin using tin electrodes

    International Nuclear Information System (INIS)

    Narasimhan, D.V.S.; Mani, R.S.

    1975-01-01

    A method for labelling human serum albumin [HSA] with sup(99m)Tc using electrolytically generated Sn/II/ ions has been developed. The procedure uses Sn electrodes for electrolysis and gives high labelling yields. The amount of Sn released into the final product was found to be much less than the reported toxic levels. A ready-to-use kit for obtaining sterile sup(99m)Tc HSA is described. Tin metal wires sealed in aluminium were irradiated in a CIRUS reactor at a neutron flux of 7.5x10 12 n cm -2 sec -1 for one month. The 113 Sn produced in the wire was used for tracer studies with the electrolitically labelled HSA. sup(99m)Tc in the form sodium pertechnetate in 0.9% NaCl was obtained by methyl ethyl ketone extraction from alkaline solutions of neutron irradiated 99 Mo [specific activity 50-200 mCi/g] in the solvent extraction generator developed at Isotope Division, BARC. Radiochemical purity analysis of sup(99m)Tc labelled HSA prepared by the above procedure was carried out by ascending paper chromatography on Whatman No.1 paper, and 85% methanol and 0.9% sodium chloride as solvents. (F.Gy.)

  16. 99mTc ovalbumin labelled eggs for gastric emptying scintigraphy: in-vitro comparison of solid food markers.

    Science.gov (United States)

    Blanc, Frédérique; Salaun, Pierre Y; Couturier, Olivier; Querellou, Solène; Le Duc-Pennec, Alexandra; Mougin-Degraef, Marie; Bizais, Yves; Legendre, Jean M

    2005-11-01

    The reliability of solid phase gastric emptying measurements by scintigraphy requires a marker that remains within the solid component of the test meal, and which is not degraded by the gastric juice throughout the scintigraphic procedure. In Europe, foods are most often labelled with 99mTc rhenium sulfide macrocolloid (RSMC) but this solid phase marker was withdrawn from the market in January 2004. To test other potential solid phase markers and to compare them to the reference marker RSMC. These markers were rhenium sulfide nanocolloid (RSNC), tin fluoride colloid (TFC), phytates and two albumins (Alb and AlbC). All were radiolabelled with 99mTc. After quality control, each 99mTc marker was incorporated into the albumin of one egg. Then, egg white and yolk were mixed together, and a well-cooked omelette was prepared. Aliquots of the omelette were incubated with an acidic solution of pepsin at 37 degrees C which mimicked gastric juice. Unbound radioactivity in the supernatant fraction was measured at various times up to 3 h. The radiochemical purity was > 95% for all radiopharmaceuticals. During the in-vitro incubation, the percentage of 99mTc labelled colloids released from the omelette increased continuously: after 3 h, 5% for TFC and RSMC, 8% for phytates, and > 9% for the two albumins and RSNC. Considering quality controls and release of 99mTc during in-vitro incubation of the omelette, TFC showed the same behaviour as the reference marker RSMC. Thus, TFC seems to be the best candidate to replace RSMC for the radiolabelling of the solid phase of the gastric emptying test meal.

  17. Effects of concurrent drug therapy on technetium /sup 99m/Tc gluceptate biodistribution

    International Nuclear Information System (INIS)

    Hinkle, G.H.; Basmadjian, G.P.; Peek, C.; Barker, K.K.; Ice, R.D.

    1982-01-01

    Drug interactions with /sup 99m/Tc gluceptate resulting in altered biodistribution were studied using chart review and animal tests. Charts of nine patients who had abnormal gallbladder uptake of technetium /sup 99m/Tc gluceptate during a two-year period were reviewed to obtain data such as concurrent drug therapy, primary diagnosis, and laboratory values. Adult New Zealand white rabbits were then used for testing the biodistribution of technetium /sup 99m/Tc gluceptate when administered concurrently with possibly interacting drugs identified in the chart review--penicillamine, penicillin G potassium, penicillin V potassium, acetaminophen, and trimethoprim-sulfamethoxazole. Chart review revealed no conclusive patterns of altered biodistribution associated with other factors. The data did suggest the possibility that the five drugs listed above might cause increased hepatobiliary clearance of the radiopharmaceutical. Animal tests showed that i.v. penicillamine caused substantial distribution of radioactivity into the gallbladder and small bowel. Minimally increased gallbladder radioactivity occurred when oral acetaminophen and trimethoprim-sulfamethoxazole were administered concurrently. Oral and i.v. penicillins did not increase gallbladder activity. Penicillamine may cause substantial alteration of the biodistribution of technetium /sup 99m/Tc gluceptate

  18. Comparison of whole-body 18F-FDG PET, 99mTc-MIBI SPET, and post-therapeutic 131I-Na scintigraphy in the detection of metastatic thyroid cancer

    International Nuclear Information System (INIS)

    Iwata, Masahiro; Kasagi, Kanji; Misaki, Takashi; Matsumoto, Keiichi; Nakamoto, Yuji; Iida, Yasuhiro; Ishimori, Takayoshi; Higashi, Tatsuya; Saga, Tsuneo; Konishi, Junji

    2004-01-01

    The usefulness of fluorine-18 fluorodeoxyglucose (FDG) positron emission tomography (PET) in differentiated thyroid cancer (DTC) has been demonstrated by many investigators, but in only a small number of studies have FDG-PET images been compared with those obtained using other non-iodine tumour-seeking radiopharmaceuticals. In most of the studies, planar imaging was performed for comparison using thallium-201 chloride or technetium-99m 2-methoxyisobutylisonitrile ( 99m Tc-MIBI). Furthermore, FDG-PET studies were not always performed in the hypothyroid state with increased levels of thyroid stimulating hormone (TSH), which are known to increase FDG uptake by DTC. The aim of this study was to compare the ability of FDG-PET to detect metastatic DTC with that of 99m Tc-MIBI whole-body single-photon emission tomography (SPET) and post-therapeutic iodine-131 scintigraphy, evaluated under TSH stimulation. Nineteen patients (8 men, 11 women; age range, 38-72 years, mean 60 years; 17 thyroidectomised and 2 inoperable patients following 131 I ablation of the remaining thyroid tissue; 16 papillary and 3 follicular carcinomas) with metastatic DTC underwent FDG-PET whole-body scan (WBS) and 99m Tc-MIBI SPET WBS at an interval of less than 1 week, followed by 131 I therapy. The SPET images were reconstructed using the maximum likelihood expectation maximisation (ML-EM) method. All patients were hypothyroid at the time of each scan. 131 I WBS was performed 3-5 days after oral administration of the therapeutic dose. A total of 32 lesions [10 lymph node (LN), 15 lung, 6 bone, 1 muscle] were diagnosed as metastases, as confirmed by histopathology and/or other imaging modalities (X-ray, US, CT, MRI, bone, 201 Tl and 131 I scans). FDG-PET, 99m Tc-MIBI SPET and post-therapeutic 131 I scintigraphy respectively revealed a total of 26 (81.3%), 20 (62.5%) and 22 (68.8%) lesions. These techniques respectively demonstrated nine (90.0%), eight (80.0%) and six (60.0%) LN metastases, and eleven

  19. Tc-99m MIBI imaging for secondary skeletal involvement in breast and prostate cancers and multiple myeloma

    International Nuclear Information System (INIS)

    Zehra, F.; Haq, S.; Fatmi, S.; Safaqat, S.

    2004-01-01

    Objective:The Objective of the study was to evaluate the role of Tc-99m MIBI whole body imaging in assessing secondary osseous involvement in patients with malignancy of breast, prostate or multiple myeloma. In this study a total of 41 patients were included. Out of these 18 had breast carcinoma, 12 had prostate carcinoma and 11 were diagnosed cases of multiple myeloma. All patients had their whole body MIBI imaging done which was compared with MDP bone scan by employing some other diagnostic modality (plain radiographs, CT scan, MRI scan or histopathological evidence) to confirm the lesions detected by either of the scans. The results of all the studies were evaluated qualitatively by assessing the number of lesions visually by three experienced nuclear physicians. Quantitative analysis of the lesions was also done, by calculating the lesion to normal uptake ratio, to augment the findings of visual assessment and for statistical analysis. Results: Results obtained in this study by MIBI and MDP imaging varied significantly among different groups and subgroups of patients depending on the primary malignancy and stage of therapy. However results obtained by imaging of patients within a group and subgroup were consistent with each other. MIBI scan showed a sensitivity of 99% in cases of multiple myeloma, where MDP scan was only 16% sensitive. In case of pre-therapy patients of breast and prostate carcinoma, the sensitivity of MIBI scan came out to be 80% and 74% respectively. In patients who were on chemo/radiotherapy MIBI scan was 54% sensitive in patients with breast carcinoma and 38% sensitive in patients with prostate carcinoma. MDP scan showed a sensitivity of 100% in all the groups. The positive predictive value of MIBI scan came out to be 100% but that of MDP was 42-76% in different groups. It is therefore concluded that the most significant role of MIBI imaging is in detection of bone metastases secondary to breast and prostate carcinoma in pre

  20. Studies on {sup 99}Mo-{sup 99m}Tc adsorption and elution behaviors using the inorganic sorbent ceric tungstate and conventional organic resins

    Energy Technology Data Exchange (ETDEWEB)

    El-Sweify, Fatma H.; Fattah, Alaa El-Din A. Abdel; Aly, Shorouk M.; Ghamry, Mohamed A. [Atomic Energy Authority, Cairo (Egypt). Hot Laboratories Center; El-Sheikh, Ragaa [Zagazig Univ. (Egypt). Chemistry Dept.

    2017-09-01

    Adsorption behavior of {sup 99}Mo(VI) and {sup 99m}Tc(VII) was studied on ceric tungstate (CeW) and compared with the adsorption on the conventional cation and anion exchangers Dowex-50X8 and AG-2X8, respectively. The studies were carried out under static and dynamic conditions. The effect of contact time and pH on the adsorption was investigated under static conditions. High K{sub d}-values for sorption of {sup 99}Mo(VI) on (CeW) were obtained over the investigated pH range. {sup 99m}Tc was adsorbed with much lower K{sub d}-values. The K{sub d}-values were pH dependent. K{sub d}-values of {sup 99}Mo-adsorption on AG-2X8 were lower than those on (CeW) and vice versa for {sup 99m}Tc. Ionic species of both elements were not adsorbed on Dowex-50X8, indicating the absence of cationic species and the adsorption of both elements on AG-2X8 and (CeW) as anionic species. The loading and elution behaviors of {sup 99}Mo and {sup 99m}Tc on (CeW) were studied using different eluents. {sup 99}Mo remained strongly adsorbed under all conditions whereas {sup 99m}Tc was easily eluted. Adsorption of some fission products, i.e. {sup 95}Zr(IV) and {sup 95}Nb(V), in addition to {sup 123m}Te(IV) and {sup 75}Se(IV), as representatives of their corresponding fission product isotopes, as well as {sup 181}Hf, as probable radioactive contaminant was also studied. Solutions of the ionic species of those metals were loaded in mixtures together with {sup 99}Mo on (CeW) columns. Strong adsorption of those ionic species and {sup 99}Mo on (CeW) was found whereas {sup 99m}Tc was easily eluted. Different eluents were investigated for eluting {sup 99m}Tc from {sup 99}Mo-adsorbed on (CeW).

  1. Biodistribution studies of {sup 99m}Tc-labeled myoblasts in a murine model of muscular dystrophy

    Energy Technology Data Exchange (ETDEWEB)

    Colombo, F.R. E-mail: colombof@policlinico.mi.it; Torrente, Y.; Casati, R.; Benti, R.; Corti, S.; Salani, S.; D' Angelo, M.G.; DeLiso, A.; Scarlato, G.; Bresolin, N.; Gerundini, P

    2001-11-01

    The purpose of this study was twofold: first, to evaluate the myoblast labeling of various {sup 99m}Tc complexes and to select the complex that best accomplishes this labeling, and second to evaluate the biodistribution of myoblasts labeled with this complex using mice with MDX muscular dystrophy (the murine homologue of Duchenne's muscular dystrophy). The following ligands were used to prepare the corresponding {sup 99m}Tc complexes: hexakis-methoxy-isobutyl-isonitrile (MIBI), bis(2-ethoxyethyl)diphosphinoethane (Tf), (RR,SS)-4,8-diaza-3,6,6,9-tetramethyl-undecane-2,10-dione-bisoxime (HM-PAO), bis(N-ethyl)dithiocarbamate (NEt), and bis(N-ethoxy, N-ethyl)dithiocarbamate (NOEt). One million murine myoblasts were incubated for 30-60 minutes with 5 mCi of each of the 99mTc complexes prepared from the above ligands. Viability was assessed by microscopic counting after trypan blue staining, and the radioactivity absorbed in the cells was measured after centrifugation. The compound with the highest uptake in cellular pellets was [{sup 99m}Tc]N-NOEt. The biodistribution of myoblasts labeled with this complex was evaluated after intraaortic injection in dystrophic mice. Such an approach has the potential of effecting widespread gene transfer through the bloodstream to muscles lacking dystrophin.

  2. Magnetic resonance Imaging (MRI) and technetium-99m-methoxyisonitrile (MIBI) scintigraphy to evaluate the abnormal parathyroid gland and PEIT efficacy for secondary hyperparathyroidism

    International Nuclear Information System (INIS)

    Wada, Akihiko; Sugihara, Masaki; Sugimura, Kazuro; Kuroda, Hiroyuki

    1999-01-01

    Percutaneous ethanol injection therapy (PEIT) of the abnormal parathyroid gland is an effective treatment in patients with chronic renal failure with dialysis that tends to be unresponsive to medication. To evaluate the efficacy of PEIT, we investigated the correlation between serum intact PTH (iPTH), and the findings of MR imaging and 99m Tc-MIBI scintigraphy. PEIT was performed 32 times in 24 patients with secondary hyperparathyroidism. Both MR imaging and MIBI scintigraphy were performed before and after PEIT. The detectability of parathyroid lesions was evaluated by MRI and MIBI scintigraphy with reference to ultrasound (B-mode) findings (as a standard) and the comparison of each treatment was done between imaging changes and serum iPTH levels. In the small parathyroid glands ( 99m Tc-MIBI scintigraphy. The reduction of high signal intensity area after PEIT on T2-weighted MR images is considered an useful therapeutic evaluation guideline than the reduction of MIBI accumulation on scintigraphy. (author)

  3. Supervising PTCA treatment with a scheme of steps combination SPECT 99Tcm-MIBI myocardial imaging

    International Nuclear Information System (INIS)

    Luan Zhaosheng; Tian Jiahe; Peng Yong; Zhou Wen; Gai Luyue; Sun Zhijun; Su Yuwen; Liu Xiaohu

    2001-01-01

    Objective: To set up a useful supervising method around PTCA treatment. Methods: A scheme of steps combination SPECT 99 Tc m -MIBI myocardial imaging was devised. 87 patients with coronary artery disease were selected into the study. 3-step imaging, exercise, rest and intravenous infusion of nitroglycerine (NTG) imaging, was performed at 1 week before PTCA. 2-step imaging, exercise and rest imaging, was performed 1-2 weeks after PTCA. All of the indexes obtained from steps combination imaging before and after PTCA were contrasted with each other in pairs. Results: 1) Compared with outcome of clinical assessing, the imaging after PTCA could correctly assess PTCA outcome. 2) The myocardial defects showed in 3-step imaging before PTCA appeared to be ameliorated after PTCA and the amelioration showed in exercise imaging was more evident than that in rest imaging. The myocardial perfusion state revealed by NTG imaging was similar to that revealed by rest imaging after PTCA. 3) The 3-step imaging findings correlated with PTCA outcome, the best correlation was found between indexes of myocardial defect changes showed by NTG and exercise imaging and indexes of PTCA outcome (r = 0.9470, P 99 Tc m -MIBI myocardial SPECT imaging scheme is a very useful supervising method around PTCA. 2-step imaging after PTCA could assess outcome correctly, and 3-step imaging before it could predict outcome correctly, too

  4. Comparison of 99mTc-HYNIC-TOC and HYNIC-TATE octreotide scintigraphy with FDG PET and 99mTc-MIBI in local recurrent or distant metastatic thyroid cancers.

    Science.gov (United States)

    Sager, Sait; Kabasakal, Levent; Halac, Metin; Maecke, Helmut; Uslu, Lebriz; Önsel, Çetin; Kanmaz, Bedii

    2013-05-01

    There have been various studies for early diagnosis of local recurrent or distant metastatic thyroid cancers. The aim of this study is to evaluate the clinical utility of 99mTc-HYNIC-TOC and 99mTc-HYNIC-TATE, octreotide derivatives, to detect recurrences or distant metastases in 131I-negative thyroglobulin positive thyroid cancer patients and to compare the lesions with FDG PET and 99mTc-MIBI studies in the same patient group. Twenty differentiated thyroid cancer patients, 7 male and 13 female, mean age 54.6 ± 15.3 (range 13-78 years), were included in this study. Eighteen patients had papillary thyroid cancer and 2 had follicular thyroid cancer. Fifteen patients received HYNIC-TOC and 5 patients received HYNIC-TATE as a radiopharmaceutical. All patients underwent whole-body scan 1 and 4 hours after injection of octreotide derivatives and SPECT imagings were performed from the suspicious sites. The lesions that were seen in 99mTc-HYNIC-TOC and 99mTc-HYNIC-TATE studies were compared with 99mTc-MIBI and FDG-PET studies. Among 99mTc-HYNIC-TOC and 99mTc-HYNIC-TATE scintigraphies, 15 patient studies were evaluated as true positive (75%) and 5 were false negative (25%). The total number of lesions in octreotide scintigraphy was 48 in 20 patients. Of 20 patients, 19 had FDG-PET study, 15 of them were evaluated as true positive (78.9%), and 4 them were evaluated as false negative (21.1%). Total number of lesions in FDG PET was 74. 99mTc-MIBI study was positive in 11 patients (55%) and negative in 9 patients (45%). Total number of lesions in 99mTc-MIBI was 25. Technetium-labeled somatostatin receptor scintigraphy analogues HYNIC-TOC and HYNIC-TATE are useful imaging alternatives in somatostatin receptor expressing thyroid cancer patients. Radiolabeling is easy and they are readily available for routine use.

  5. /sup 99m/Tc labeling of antibodies to cardiac myosin Fab and to human fibrinogen

    International Nuclear Information System (INIS)

    Khaw, B.A.; Strauss, H.W.; Carvalho, A.; Locke, E.; Gold, H.K.; Haber, E.

    1982-01-01

    We have developed a method of labeling biologically active labile macromolecules, such as human fibrinogen (HF) and anticardiac-myosin Fab (AM-Fab), with /sup 99m/Tc at neutral pH. This method uses dithionite reduction of pertechnetate and subsequent labeling, to test the method with acid-labile macromolecules. Complexes of diethylene triamine pentaacetic acid with macromolecules such as human fibrinogen (D-HF) and anticardiac-myosin Fab (D-AM-Fab) were labeled and utilized in in vitro and in vivo studies. In biodistribution studies, the /sup 99m/Tc D-HF had a two-component blood clearance (half-times 1 hr and 15 hr) and was 80--88% coagulable. The /sup 99m/Tc AM-Fab retained its immunoreactivity as tested by affinity chromatography; also during in vivo localization in experimental myocardial infarction. This labeling technique provides an easy and efficient approach to the /sup 99m/Tc labeling of other biologically active and acid-labile macromolecules

  6. Development, preparation and control of sup(99m)Tc or sup(113m)In labelled stannous hydroxide radiopharmaceuticals. Part of a coordinated programme on radiopharmaceuticals

    International Nuclear Information System (INIS)

    Alvarez Cervera, J.

    1975-01-01

    The preparation of different sup(99m)Tc and sup(113m)In radiopharmaceuticals using stannous chloride was investigated. Chemical and radiochemical procedures for the quality control of these preparations were studied. Toxicity and biological controls of the preparation were carried out. Procedures for the preparation and control of the following radiopharmaceuticals have been standardized by the authors; albumin macroaggregates labelled with sup(99m)Tc, sup(113m)In and other isotopes for lung scanning; albumin microspheres labelled with sup(99m)Tc for lung scanning; sup(99m)Tc or sup(113m)In-labelled stannous hydroxide colloid for liver scanning; sup(99m)Tc-stannous phytate for liver scanning; sup(99m)Tc-Sn-dextrose, a new radiopharmaceutical which has been proposed by the authors and is now used in Mexico for renal and cerebral scanning and sup(99m)Tc-Sn pyrophosphate and diphosphonate for bone scanning

  7. Technetium 99mTc Pertechnetate Brain Scanning

    International Nuclear Information System (INIS)

    Rhee, Sang Min; Park, Jin Yung; Lee, Ahn Ki; Chung, Choo Il; Hong, Chang Gi; Rhee, Chong Heon; Koh, Chang Soon

    1968-01-01

    Technetium 99 mTc pertechnetate brain scanning were performed in 3 cases of head injury (2 chronic subdural hematomas and 1 acute epidural hematoma), 2 cases of brain abscess and 1 case of intracerebral hematoma associated with arteriovenous anomaly. In all the cases brain scintigrams showed 'hot areas.' Literatures on radioisotope scanning of intracranial lesions were briefly reviewed. With the improvement of radioisotope scanner and development of new radiopharmaceuticals brain scanning became a safe and useful screening test for diagnosis of intracranial lesions. Brain scanning can be easily performed even to a moribund patient without any discomfort and risk to the patient which are associated with cerebral angiography or pneumoencephalography. Brain scanning has been useful in diagnosis of brain tumor, brain abscess, subdural hematoma, and cerebral vascular diseases. In 80 to 90% of brain tumors positive scintigrams can be expected. Early studies were done with 203 Hg-Neohydrin or 131 I-serum albumin. With these agents, however, patients receive rather much radiation to the whole body and kidneys. In 1965 Harper introduced 99 mTc to reduce radiation dose to the patient and improve statistical variation in isotope scanning.

  8. Preparation and labelling hydroxyapatite with 223Ra and 99mTc

    International Nuclear Information System (INIS)

    Malkova, E.; Micolova, P.; Vlk, M.; Kozempel, J.; Rabyk, M.

    2015-01-01

    The aim of this study was the preparation, studies and investigation of novel nanoparticles suitable for targeted delivery of 223 Ra and 99 mTc. Preliminary experiments were focused on the synthesis of hydroxyapatite nanoparticles (HANPs) and their affinity to 223 Ra and 99m Tc. Technetium-99m ( 99 mTc, T 1 /2 = 6.0 h) is the most commonly used medical radionuclide for diagnostic procedures. Radium-223 is the first -emitting radionuclide approved for targeted radionuclide therapy. The physical half-life of 223 Ra of 11.4 days is providing sufficient time for the synthesis, distribution and administration of the radiopharmaceutical to patients. HANPs labelling yields with 223 Ra were 95 - 100 % and with 99m Tc were 93 - 94 % depending on the reaction conditions. HANPs were studied on FT-IR (Fourier transform infrared spectroscopy), XRPD (X-Ray Powder Diffraction), DLS (Dynamic Light Scattering), and the sizes of nanoparticles were studied at temperatures 80, 120 and 200 grad C. (authors)

  9. {sup 99m}Tc-MIBI scintigraphy for early detection of locally recurrent non-small cell lung cancer treated with definitive radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Furuta, Masaya; Nozaki, Miwako; Kawashima, Miho; Iimuro, Mamoru; Kitazumi, Yoshinori; Okayama, Aya; Natsui, Satoshi [Department of Radiology, Koshigaya Hospital, Dokkyo University School of Medicine, 2-1-50 Minami-Koshigaya, 343-8555, Koshigaya (Japan); Hamashima, Yoshio; Nagao, Koushuu [Department of Respiratory Internal Medicine, Koshigaya Hospital, Dokkyo University School of Medicine, Koshigaya (Japan)

    2003-07-01

    After radiation therapy of lung cancer, a dense fibrotic shadow develops in the irradiated lung. Owing to this fibrosis, early detection of local recurrence after treatment is sometimes difficult even when using computed tomography (CT) and magnetic resonance imaging. We investigated the diagnostic accuracy of technetium-99m hexakis 2-methoxyisobutylisonitrile ({sup 99m}Tc-MIBI) scintigraphy for the detection of recurrent lung cancer following definitive radiation therapy. Eighteen patients with primary non-small cell lung cancer treated with radiation therapy 1 year previously were studied with {sup 99m}Tc-MIBI scintigraphy. They showed no evidence of local recurrence on serial chest radiographs. All single-photon emission tomography (SPET) images acquired 2 h after intravenous administration of the radiopharmaceutical were visually interpreted with knowledge of the pretreatment chest radiograph, CT and the details of radiation therapy (radiation portals and administered doses). A region of interest (ROI) analysis was also performed. In addition to the ROI ratio of tumour uptake to accumulation in contralateral normal lung (tumour/lung ratio), another semiquantitative analysis, the ratio of tumour uptake to accumulation in radiation fibrosis (tumour/fibrosis ratio), was performed to differentiate between accumulation in radiation fibrosis and the tumour uptake. The scintigraphic diagnoses were correlated with clinical outcome. The sensitivity, specificity and negative predictive value of {sup 99m}Tc-MIBI scintigraphy for the detection of recurrent lung cancer were all 88.9% (8/9). The tumour/lung ratios (mean{+-}SEM) of the nine patients with local recurrence and the other eight without local failure were 2.00{+-}0.11 and 1.40{+-}0.09, respectively (P<0.01). The tumour/fibrosis ratios of the patients with and those without recurrence were 1.47{+-}0.08 and 0.93{+-}0.05, respectively (P<0.01). These results suggest that {sup 99m}Tc-MIBI scintigraphy might be of

  10. Development and utilization of the inorganic polymer materials for {sup 99}Mo-{sup 99m}Tc and {sup 188}W-{sup 188}Re generator based on (n, gamma) method

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Kosuke; Ishikawa, Koji; Terunuma, Hitoshi; Hasegawa, Yoshio; Tatenuma, Katsuyoshi [KAKEN Co., Mito, Ibaraki (Japan)

    2003-03-01

    A molybdenum (Mo) adsorbent called PZC (Poly Zirconium Compound) with high efficiency of Mo adsorption has been developed in order to generate {sup 99m}Tc from {sup 99}Mo produced from natural Mo by (n, gamma) method. The {sup 99m}Tc generator using PZC has cleared mostly the technical subjects. By the results of many experiments, cold and hot test with {sup 99}Mo activity from low level (10{sup 5} Bq) to high level (10{sup 10} Bq), it has been confirmed that the PZC method can be practically applied for the (n, gamma) {sup 99}Mo-{sup 99m}Tc generator. From the reasons that PZC has the ability and many merits such as high adsorption capacity (>250 mg-Mo/g-PZC) of Mo, high elution yield (av. 80%) of {sup 99m}Tc, the low breakthrough (<0.05 kBq-{sup 99m}Mo/MBq-{sup 99m}Tc) of {sup 99}Mo and others, the current (n, fission) {sup 99m}Tc generator utilizing {sup 99}Mo produced from enriched uranium will be taken the place by PZC method. In this paper, the practicability of PZC and a newly developed functional material PTC(Poly Titanium Compound) as the (n, gamma) {sup 99}Mo-{sup 99m}Tc generator, and an ability of PZC as the {sup 188}W-{sup 188}Re generator will be shown. (author)

  11. Background {sup 99m}Tc-methoxyisobutylisonitrile uptake of breast-specific gamma imaging in relation to background parenchymal enhancement in magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Hai-Jeon; Kim, Bom Sahn [Ewha Womans University, Department of Nuclear Medicine, Yangchun-Ku, Seoul (Korea, Republic of); Kim, Yemi [Ewha Womans University, Clinical Research Institute and Department of Conservative Dentistry, Seoul (Korea, Republic of); Lee, Jee Eun [Ewha Womans University, Department of Radiology, Seoul (Korea, Republic of)

    2015-01-15

    This study investigated factors that could affect background uptake of {sup 99m}Tc- methoxyisobutylisonitrile (MIBI) on normal breast by breast-specific gamma imaging (BSGI). In addition, the impact of background {sup 99m}Tc-MIBI uptake on the diagnostic performance of BSGI was further investigated. One hundred forty-five women with unilateral breast cancer who underwent BSGI, MRI, and mammography were retrospectively enrolled. Background uptake on BSGI was evaluated qualitatively and quantitatively. Patients were classified into non-dense and dense breast groups according to mammographic breast density. Background parenchymal enhancement (BPE) was rated according to BI-RADS classification. The relationship of age, menopausal status, mammographic breast density, and BPE with background {sup 99m}Tc-MIBI uptake was analyzed. Heterogeneous texture and high background uptake ratio on BSGI were significantly correlated with younger age (p < 0.001, respectively), premenopausal status (p < 0.001 and p = 0.003), dense breast (p < 0.001, respectively), and marked BPE (p < 0.001, respectively). On multivariate analysis, only BPE remained a significant factor for background MIBI uptake (p < 0.001).There was a significant reduction in positive predictive value (p = 0.024 and p = 0.002) as background MIBI uptake and BPE grade increased. BPE on MRI was the most important factor for background MIBI uptake on BSGI. High background MIBI uptake or marked BPE can diminish the diagnostic performance of BSGI. (orig.)

  12. /sup 99m/Tc labelled ulcer avid agents

    International Nuclear Information System (INIS)

    Scopinaro, F.; Linari, G.; Baldieri, M.; Liberatore, M.; Corti, E.; Signori, C.

    1986-01-01

    Sulfated oligosaccharides have some interesting pharmacological properties: they are anticoagulants and protect the ulcerative areas of epithelia by precipitating over ulcers together with exudative proteins. Some sucralfate labelling methods using /sup 75/Se, /sup 111/In, /sup 99m/Tc-albumin and /sup 99m/Tc-DTPA have been reported. Only the /sup 99m/Tc-sucralfate has, at present, the requisites to be used as an ulcer-seeking agent. The aim of this study were: (a) to introduce a simple and easy-to-repeat method for the labelling of sucralfate with /sup 99m/Tc-DTPA; (b) to demonstrate that it is possible to label the sucrose octasulfate directly with /sup 99m/Tc without the aid of other ligands (e.g. DTPA)

  13. Predictive value of brain SPECT with 99 technetium - MIBI for differentiation of histologic grade brain gliomas

    International Nuclear Information System (INIS)

    León Castellón, Roberto; Martín Escuela, Juan Miguel; López Díaz, Ing. Adlin; Salva Camaño, Silvia; Gómez Viera, DrC. Nelson; San Pedro, Aley Palau; Castro Jiménez, Mayté

    2016-01-01

    Diagnosis and treatment of primary tumors of the nervous system remain difficult and are a challenge to be addressed in a multidisciplinary way. In order to determine the usefulness of brain SPECT 99 Tc MIBI to differentiate histologic grade brain gliomas - Frequently brain tumors - they were studied 68 patients with this technique. A dynamic study first step in AP and lateral view was performed, and a SPECT at 20 minutes post-administration and at 2 hours late views. the post-surgical histological study of injuries was used as control. several imaging parameters such as the absolute activity of 99m Tc-MIBI were calculated both early and late phase, cortex contralateral tumor rates; pituitary tumor; choroid plexus tumor and Reason Late / Early phase tumor index / contralateral cortex tumor volume functional phase, the volume concentration of MIBI activity in the tumor and the retention rate of the radiopharmaceutical. Of the 68 patients studied, 11 were high-grade tumors and 57 low grade. The cortex contralateral tumor in late stage index showed a negative satisfactory sensitivity of 98.6% and specificity 77.1%, positive predictive value (PPV) of 48.2% and (NPV) of 99.8%. The reason late stage / early in the index tumor / contralateral cortex showed values ​​in turn 96.3%, 98.7%, 98.8% and 98.8% sensitivity, specificity, PPV and NPV respectively. The retention rate showed a 99% sensitivity, 89% specificity and PPV, NPV of 95% and 99% respectively. Conclusion: The combination cortex contralateral tumor rate in late stage, the reason late stage / early stage tumor index / contralateral cortex and the retention rate of the radiopharmaceutical are the most useful parameters to predict histologic grade of brain gliomas. (author)

  14. Technology of the sup(99m)Tc generator, Elumatic III made by Commissariat a l'Energie Atomique, France

    International Nuclear Information System (INIS)

    Le Bris, H.; Pasqualini, R.; Reboul, J.

    1982-01-01

    The article describes the choices leading to the development of an ''integrated'' 99 Mo-sup(99m)Tc generator meeting the following requirements: (a) total activity eluted in a volume of 5 ml; (b) adequate radioprotection both for the user and the manufacturer; (c) injectable eluate. (author)

  15. Labelling, biodistribution and compartmental analysis of N-acetylcysteine labelled with Tc-99m. Comparative investigation with with 99m Tc-MIBI in an in vivo tumoral model

    International Nuclear Information System (INIS)

    Faintuch, Bluma Linkowski

    1997-01-01

    Labelling and biodistribution studies were done with two different ligands, respectively Methoxy isobutyl isonitrile (MIBI) and N-acetylcysteine (NAC), employing Tc-99m as a tracer. The main objective was to assess the pharmacokinetic properties of the second substance, aiming at its possible application in cancer diagnosis. To this purpose an in vivo investigation was done using healthy and tumor-bearing rats with experimental cancer. Images of tumor-bearing rats registered in a scintillation camera indicated that with 99m Tc-MIBI none of the two selected times was adequate for visualization of the cancer mass. In contrast, 99m Tc-NAC permitted clear identification of the humor, four hours after injection. The results have demonstrated that 99m Tc-NAC is a radiopharmaceutical with affinity for cancer tissue and promising for further investigation concerning imaging diagnosis of tumors. (author)

  16. An embedded system based computer controlled process automation for recovery and purification of 99mTc from (n,γ)99Mo

    International Nuclear Information System (INIS)

    De, Anirban; Pal, S.S.; Bhaskar, P.; Kumari, S.; Khare, V.K.; Duttaroy, A.; Garai, M.; Thakur, S.K.; Saha, S.; Chattopadhyay, Sankha; Barua, Luna; Das, Sujata Saha; Kumar, U.; Das, M.K.

    2012-01-01

    99 Mo produced 99 mTc (t 1/2 = 6 hr, 140 KeV γ-ray) is the most useful radioisotope for nuclear diagnostics. High specific activity 99 Mo is supplied globally mainly by five old reactors whose routine or unscheduled maintenance shutdown causes supply irregularities that adversely affects patient management in nuclear medicine centres. 99m Tc may also be produced via 98 Mo(n,γ) in a natural MoO 3 target in reactor or by 100 Mo(n,2n) 99 Mo or 100 Mo(p,2n) 99 mTc reaction in cyclotron. To meet the crisis proposals are there to produce 99 Mo by 100 Mo(n,2n) 99 Mo or 99m Tc directly by 100 Mo(p,2n) 99m Tc in a cyclotron. Of the several separation methods of 99 mTc from molybdenum, the most common are adsorption column chromatography, sublimation and liquid-liquid solvent extraction. The conventional methods besides being cumbersome are often hazardous, polluting, require skilled manpower and facilities like fume hood and so are not always practically feasible for hospitals. To address these, VECC and BRIT, Kolkata have collaborated to develop an embedded system based automated 99 Mo/ 99m Tc generator from low specific activity 99 Mo using solvent extraction technique, supervised by a PC based GUI. (author)

  17. Evaluation of sup(99m)Tc-albumin dilution curve with simultaneous injection of sup(99m)Tc- and 131I-albumins

    International Nuclear Information System (INIS)

    Kinoshita, Masahiko; Kato, Shotaro; Motomura, Masakazu; Kawakita, Seiichi

    1979-01-01

    A critical comparison of radiocardiograms with sup(99m)Tc- and 131 I-albumins was made to determine whether or not sup(99m)Te-albumin can be used as a tracer for measuring blood volume (BV) and cardiac output (CO). Simultaneous injection of both isotopes was given to twenty-two patients to obtain radiocardiograms for each by means of a single scintillation counter with two pulse height analyzers. Such method allows for the determination of the energy levels for both sup(99m)Tc and 131 I. The radiocardiographic pattern was somewhat different between sup(99m)Tc- and 131 I-radiocardiograms: The ratio of left to right peak height was 16% on the average lower in the sup(99m)Tc-radiocardiogram than in the 131 I-one. The reason for the lower ratio is explained by greater absorption of sup(99m)Tc-radioactivity within the soft tissue interposing between the scintillation probe and heart. The values for sup(99m)Tc-derived blood volume were 7.4% on the average larger than those for 131 I-derived blood volume (p less than 0.01), although the correlation was excellent (r = 0.98 p less than 0.01). There was no systemic difference between cardiac output determined by sup(99m)Tc- and 131 I-albumins since the overestimation of blood volume can compensate for the underestimation of CO/BV by sup(99m)Tc-study. In view of its rapid extravasation, sup(99m)Tc-albumin is not so appropriate tracer for accurate measurements of BV and CO/BV, although it may be used for measurement of cardiac output. (author)

  18. Diagnostic ability of Tc-99m MIBI SPECT in coronary artery diseases in not affected by the degree of exercise

    International Nuclear Information System (INIS)

    Lee, Jae Tae; Kim, Jong Soo; Chun, Kyung Ah; Lee, Sang Woo; Kang, Do Young; Cho, Yong Keun; Chae, Shung Chull; Lee, Kyu Bo

    1999-01-01

    The sensitivity of ST-depression in the electrocardiogram during exercise is influenced by the level of efforts. However, unlike the prevalence of ST-depression of exercise ECG, the degree of exercise is reported to do not influence the diagnostic ability of myocardial perfusion scan. Furthermore, the relation between the prevalence of myocardial ischemia and effort is still controversial. We evaluated the effect of the degree of exercise on the ability of SPECT imaging to detect coronary artery stenosis. The patient population was comprised of 111 patients (73 men and 38 women, mean age 56 years) who underwent an exercise test in conjunction with Tc-99m MIBI and cardiac catheterization within 3 months apart each other. The degree of exercise was classified into four groups according to the percentage of maximal predicted heart rate. The sensitivity and specificity was compared between each group. The overall diagnostic sensitivity was significantly higher with Tc-99m MIBI SPECT than exercise ECG. The specificity was not significantly different between two tests. Sensitivity and specificity of Tc-99m MIBI was not different between four groups. Sensitivity for individual coronary stenosis seemed to be lower in subjects who had premature termination of exercise due to early appearance of ST depression. These results suggest that the overall diagnostic sensitivity of Tc-99m MIBI myocardial perfusion SPECT is not significantly affected by the degree of exercise in stable patients undergoing symptom-limited treadmil exercise testing. Myocardial perfusion SPECT imaging should be added to routine exercise stress testing for the detection of coronary artery disease

  19. Clinical evaluation of adenosine and exercise stress 99Tcm-MIBI myocardial imaging in detection of myocardial ischemia in patients with untypical chest pain

    International Nuclear Information System (INIS)

    Tian Yueqin; He Zuoxiang; Wang Qi; Hu Fenghuan; Yang Weixian; Qiao Shubing; Liu Xiujie

    2005-01-01

    Objective: To evaluate the value of adenosine and exercise stress 99 Tc m -methoxyisobutylisonitrile (MIBI) myocardial imaging for the diagnosis of myocardial ischemia in patients with untypical chest pain. Methods: Two groups included. Group 1: 67 cases of adenosine 99 Tc m -MIBI myocardial imaging. Group 2: 81 cases of exercise stress 99 Tc m -MIBI myocardial imaging. All of the patients had coronary angiography (CAG). The results of them were compared. Results: 23 out of 67 patients in group 1 had significant coronary stenosis after CAG, 16 showed reversible perfusion abnormalities in adenosine imaging. 41 of 44 patients with normal CAG showed normal adenosine imaging. The sensitivity, specificity and accuracy of adenosine imaging for coronary artery disease detection were 70%, 93% and 85%, respectively. Group 2: 22 out of 31 patients with significant coronany stenosis after CAG showed reversible perfusion abnormalities, 48 of 50 patients with normal CAG showed normal exercise imaging. The sensitivity, specificity and accuracy of exercise imaging for coronary artery disease detection were 71%, 96% and 86%, respectively. Conclusion: Reversible perfusion abnormalities found both in adenosine and exercise stress 99 Tc m -MIBI myocardial imaging were the key point for diagnosis of myocardial ischemia in patients with untypical chest pain. (authors)

  20. Evaluation of '9{sup 9}Mo presence in eluates of {sup 99}mTc used in nuclear medicine; Avaliacao da presenca de {sup 99}Mo em eluatos de {sup 99m}Tc utilizados em medicina nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Bianca da Silva

    2010-07-01

    Tc-99m is used for diagnostic imaging in nuclear medicine through SPECT technique. It is obtained by the elution of {sup 99}Mo/{sup 99m}Tc generators. During the elution process {sup 99}Mo can be extracted becoming a radionuclidic impurity. One of the quality parameters of the eluate is the radionuclidic purity, MBT (molybdenum break through), defined as the ratio between {sup 99}Mo and {sup 99m}Tc activities in the eluate. The North-American and European pharmacopoeias restrict the {sup 99}Mo content, respectively, in 0.015 e 0.1% and, according to the International Atomic Energy Agency (IAEA), the activity ratio at the moment of administration of the radiopharmaceutical to the patient, should not exceed 0.015%. In Brazil, the control of such parameter is not obliged in official regulations. Thus, the objective of this work is to evaluate the occurrence of {sup 99}Mo in {sup 99m}Tc eluates. It was initially optimized a methodology to determine the activity of {sup 99}Mo in eluate samples. Efficiency curves were obtained for a NaI (Tl) 8'' x 4'' scintillation detector installed at the In Vivo Monitoring Laboratory (LABMIV-IRD). The methodology has been validated through the measurement of a {sup 99}Mo standard liquid source calibrated at the National Metrology Laboratory for Ionizing Radiation (LNMRI-IRD). The samples analyzed in this work were gently supplied by 5 Nuclear Medicine Clinics located in the city of Rio de Janeiro. The activities of {sup 99}mTc and {sup 99}Mo in those samples have been measured respectively at the clinics and at the LABMIV. By applying a standardized methodology, the ration between the activities were calculated. The results show that 147 out of 174 samples presented {sup 99}Mo activities above the minimum detectable activity of the technique. On the other hand, only 2 out of 147 samples surpassed the MBT limit suggested by the IAEA and have been detected in samples eluted from generators of 750 mCi. In one of the

  1. Profile of MIBI liquid phase radiopharmaceutical for myocardial imaging

    International Nuclear Information System (INIS)

    I Daruwati; ME Sriyani; NK Oekar; N Zainuddin; KA Hanafiah

    2016-01-01

    The 99m Tc-MIBI radiopharmaceutical has been used in nuclear medicine in Indonesia for myocardial imaging. BATAN researchers have mastered the technology to manufacture MIBI as a lyophilized kit. A reformulation of MIBI radiopharmaceutical has been conducted to improve the stability of the kit especially in the liquid-phase kit. Basically, radiopharmaceuticals in liquid form are not different from the dry kit. However in the manufacturing of liquid-phase kit, lyophilization process was not done. To improve the stability of liquid kit, a reformulation of the components was conducted by using two separate vials (Formulation 2) and the characteristics were compared with the one-vial formulation (Formulation 1). The MIBI Formulation 2 consists of two vials, vial A containing 0.06 mg of SnCl 2 2H 2 O and 2.6 mg Sodium Citrate 2H 2 O and vial B containing 0.5 mg of [Cu(MIBI) 4 ]BF 4 , 1 mg of cysteine hydrochloride, and 20 mg of mannitol. The purposes of this study were to determine the stability of two different formulations of MIBI as a liquid-phase kit, to compare their stability in different storage condition such as in refrigerator and freezer, and to compare the ratio of activities attained between target and nontarget organs after injection to animal model. As a diagnostic agent, MIBI was reconstituted with Technetium-99m as radionuclide tracer to 99m Tc-MIBI labeled compound. The radiochemical purity of 99m Tc-MIBI was determined by chromatography method using alumina thin-layer chromatography paper as the stationary phase and ethanol 95% as the mobile phase. The results showed MIBI Formulation 2 has a higher stability than Formulation 1. Formulation 2 also maintained a 96.68% radiochemical purity under 52-day storage and attained a target-to-nontarget activity ratio of 8.22. (author)

  2. '99Mo/99mTc Generator Based on High Radionuclidic Pure Zirconium Molybdate Gel

    International Nuclear Information System (INIS)

    Amin, M.; Mostafa, M.; El-Amir, M.A.; El-Absy, M.A.; Mohamed, O.I.; Farag, A.B.

    2014-01-01

    99 Mo / 99 mTc radioisotope generator was prepared using in-situ precipitated zirconium molybdate chromatographic column. Zirconium molybdate gel matrix was synthesized by precipitation of neutron activation molybdenum-99 from its solution after variety purification processes to prevent contamination of the 99m Tc eluate with cross-contaminants. Greeter than 82.7 ± 0.4 % of the generated 99m Tc was immediately and reproducible eluted by passing 10 ml 0.9 % NaCl solution through the 1 g zirconium molybdate- 99 Mo column matrix at a flow rate of 0.5 ml / min and room temperature with high chemical, radionuclide ( ≥ 99.9 % 99m Tc) and radiochemical purity ( ≥ 97.7 % % as 99 mTcO 4 - ) with ph value suitable for medical uses.

  3. Comparison of technetium-99m methoxyisobutylisonitrile and gallium-67 citrate scanning in the assessment of lymphomas

    International Nuclear Information System (INIS)

    Ziegels, P.; Nocaudie, M.; Huglo, D.; Deveaux, M.; Detourmignies, L.; Wattel, E.; Marchandise, X.

    1995-01-01

    The aim of this study was to compare the value of scintigraphy using technetium-99m methoxy-isobutylisonitrile (MIBI) with that of scintigraphy using gallium-67 citrate in the assessment of Hodgkin's disease and non-Hodgkin's lymphoma and to relate these results with those of CT scan and MRI. Fifty-eight patients were included either for a follow-up examination or for monitoring of their treatment. Twenty-three residual masses were studied. A whole-body scan was performed, followed by single-photon emission computed tomography (SPET) 20 min after injection of 740 MBq of 99m Tc-MIBI and 72 h after injection of 185 MBq of 67 Ga citrate. The overall sensitivity of 99m Tc-MIBI and 67 Ga citrate was 71% and 68%, respectively, and the overall specificity was 76% and 44%, respectively. For residual masses, the sensitivity was 44% with both tracers and the specificity was 80% with 99m Tc-MIBI and 53% with 67 Ga citrate. The positive predictive values were 85% and 68% and the negative predictive values were 59% and 44%, respectively. The signal-to-background ratio was 1.5 for 99m Tc-MIBI and 2 for 67 Ga citrate. At present, 99m Tc-MIBI cannot replace 67 Ga citrate in the assessment of lymphomas. (orig.)

  4. Development of 99mTc agents for imaging central neural system receptors

    International Nuclear Information System (INIS)

    2004-01-01

    Radiopharmaceuticals that bind to central neural system (CNS) receptors in vivo are potentially useful for understanding the pathophysiology of anumber of neurological and psychiatric disorders, their diagnosis and treatment. Carbon-11 labelled compounds and positron emission tomography(PET) imaging have played a vital role in establishing the usefulness of imaging the dopaminergic, cholinergic, serotonergic and benzodiazapine receptors, and relating the receptor density to disease status. Since the use of 11C agents is constrained due to their 20 min half-life, various radiohalogenated analogues based on the structure of 11C compounds have been successfully developed, providing comparable information. Iodine- 123 is the most widely employed of these radioisotopes; it has a longer, 13 h, half-life. Through the use of 123I, there has been a steady growth in CNS receptor imaging studies employing single photon emission computerized tomography (SPECT). SPECT, as compared with PET, has slightly inferior image resolution but has the advantage of being readily available worldwide. However, the 123I radiopharmaceutical is expensive and the distribution system outside of the major markets is not well developed for its supply on a routine basis. The ideal radioisotope for SPECT imaging is 99mTc, due to its low cost per dose, availability through commercially available generator systems and physical decay characteristics. Over 80% of all diagnostic nuclear medicine imaging studies worldwide are conducted using this radioisotope. Development of 99mTc radiopharmaceuticals for imaging CNS receptors is therefore of considerable importance. On the basis of the recommendations of a consultants meeting, the International Atomic Energy Agency (IAEA) initiated in 1996 a Co-ordinated Research Project (CRP) on Development of Agents for Imaging CNS Receptors based on 99mTc. At that time there were no 99mTc CNS receptor imaging radiopharmaceuticals available even though work on

  5. Localization of the acute lower gastrointestinal hemorrhage in vivo-in vitro labeling of red blood cells with sup(99m)Tc

    International Nuclear Information System (INIS)

    Noguera, E.; Mothe, G.; Wyse, E.

    1984-01-01

    For the detection and localization of acute lower gastrointestinal hemorrhage in vivo-in vitro labeling of red blood cells with sup(99m)Tc and sup(99m)Tc sulfur colloid has been sugested. The procedure for labeling RBC with sup(99m)Tc consisted in injecting IV 1 mg of ClSn; 20 minutes after injection of tin 10 cc of blood were withdrawn in a syringe containing 20 mCi of sup(99m)Tc; this was incubated for 10 minutes and then injected IV. Scintigraphy of the abdominal cavity was done in supine position and performed with a large field gamma camera with a parallel hole-low energy colimator. Computer adquisition of images was started 5 minutes after RBC injection and made at the rate of one enery 5 minutes for 45 minutes. 14 patients were studied divided in: a) control: 6 patients. b) with active gastrointestinal hemorrhage: 4 patients had positive scintigraphy. The hemorrhage was documented with superior mesenteric arteriography, endoscopy and/or necropsy. The sensitivity was 100%. In 4 out of 14 patients scintigraphy with sup(99m)Tc RBC compared with simultaneous sup(99m)Tc sulfur colloid demonstrated that all patients with positive sup(99m)Tc RBC had also positive sup(99m)Tc sulfur colloid scintigraphy. c) without active gastrointestinal hemorrhage: all of them had negative scintigraphy (specificity 100%). Abdominal scintigraphy with sup(99m)Tc RBC or sulfur colloid are both sensitive for detection and localization of lower gastrointestinal bleeding and the negative study suggests the absence of active hemorrhage. It is suggested that the sup(99m)Tc sulfur colloid scintigraphy should be the initial procedure to study these patients and abdominal arteriography should be performed only in patients with positive abdominal scintigraphy. (M.E.L.) [es

  6. Evaluation of brain tumors by simultaneous dual isotope SPECT with 201Tl-chloride and 99mTc-MIBI

    International Nuclear Information System (INIS)

    Nagai, Hidemasa; Yamasaki, Toshiki; Yamamoto, Yoshiaki; Takada, Daikei; Miyazaki, Takeshi; Sugimoto, Keiji; Matsumoto, Yoshifumi; Akiyama, Yasuhiko; Moritake, Kouzo

    2004-01-01

    Single photon emission computed tomography (SPECT) is useful for detecting brain tumors. In this study, we evaluated the utility of simultaneous dual SPECT with 201 Tl-Chloride (Tl) and 99m Tc-MIBI (MIBI) for diagnosis of brain tumors. We evaluated 20 cases, including 2 glioblastomas, 7 anaplastic astrocytomas, 2 oligodendrogliomas, 2 anaplastic ependymomas, 2 medulloblastomas, 2 meningiomas, 1 malignant meningioma, 1 pituitary adenoma, and 1 craniopharyngioma. We analyzed the uptake ratio (T/N ratio) of tracers in both Tl and MIBI at max counts/pixels ratio in the region of interest. The T/N ratios in early and delayed images were described as early ratios (ER) and delay ratios (DR), respectively. The retention index (RI) was calculated as the DR/ER ratio. Significant correlations were found between ER and DR for both Tl (DR=0.797 x ER+0.359, r=0.871), and MIBI (DR=0.961 x ER-0.191, r=0.784). Next, we analyzed the correlations between Tl and MIBI SPECT, for ER, DR, and RI. ER values for the two were strongly correlated (r=0.791), DR values were weakly correlated (r=0.556), and RI exhibited no correlation between them (r=0.328). There were no correlations between tumor volume and T/N ratio for the two (ER-Tl; r=0.0095, DR-Tl; r=0.0050, ER-MIBI; r=0.036, DR-MIBI; r=0.254). Lastly no correlation was found between RI-Tl and RI-MIBI (r=0.328). We discuss the difference in the mechanism of accumulation of two tracers and the significance of simultaneous dual SPECT using them for the differential diagnosis of pituitary tumors, regrowth of oligodendrogliomas, and multi-drug resistance of chemotherapy. Dual SPECT with Tl and MIBI appears to be useful for the diagnosis of brain tumor. (author)

  7. Relationship Between Adenosine - Induced ST Segment Depression During 99mTc-MIBI Scintigraphy and The Severity of Coronary Artery Disease

    International Nuclear Information System (INIS)

    Cho, Jung Ah; Choi, Jung Il; Kwak, Dong Suk

    1994-01-01

    Pharmacologic coronary vasodilation in conjunction with myocardial perfusion scintigraphy has become an alternative to dynamic exercise test for the diagnosis and risk stratification of coronary artery disease, especially in patients who are unable to perform adequate exercise. Dipyridamole and adenosine have been used for pharmacologic stress testing with myocardial perfusion imaging. Adenosine is a potent, coronary vasodilator with rapid onset of action, short half life, near maximal coronary vasodilation and less serious side effects. ST segment depression has been reported in about 7-15% of patients with coronary artery disease receiving dipyridamole in conjunction with myocardial perfusion imaging. The exact cause and clinical significance are not known. In order to evaluate the relationship between adenosine-induced ST segment depression during 99m Tc-MIBI myocardial perfusion scintigraphy and the severity of coronary artery disease, we performed 99m -MIBI imaging after intravenous infusion of adenosine in 120 patients with suspected coronary artery disease. Of the 120 patients, 28 also performed coronary angiography. There were 24 patients with ST segment depression during 99m Tc-MIIBI scintigraphy and 96 patients without ST segment depression. Adenosine was infused intravenously at a dose of 0.14 mg/kg per minute for 6 minutes and 99 MmTc-MIB1 was injected at 3 minute. We then compared the hemodynamic changes, side effects, scintigraphic and angiographic findings. Heart rate increased 90 ± 19 beats/minute in the group with ST depression compared with 80 ±16 beats/minute in the group without ST depression(p 9m Tc-MIBI images were abnormal in 23(96%) patients with ST segment depression and 66(69%) patients without ST segment depression(p 99m Tc-MIBI myocardial perfusion scintigraphy with intravenous adenosine is related to the severity of coronary artery disease.

  8. Evaluation of the quality of the radiopharmaceutical 99mTc-MIBI and its influence on image quality in myocardial perfusion scintigraphy; Avaliacao da qualidade do radiofarmaco {sup 99m}Tc-MIBI e sua influencia na qualidade da imagem em cintilografia de perfusao do miocardio

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Poliane Angelo de Lucena

    2013-07-01

    This study evaluated the quality of the {sup 99m}Tc-MIBI radiopharmaceutical from different manufacturers, used in three nuclear medicine services (NMS) in Recife-PE, through labeling procedure of each service. It was observed their biodistribution by quantifying the activity present in the organs of interest (heart / liver), the influence and interference in image quality and in myocardial scintigraphy diagnosis exam. In these NMS (A, B and C) were done quality controls in the eluates of {sup 99}Mo/{sup 99m}Tc generators (radionuclidic, chemical and radiochemical purity and pH) and of the {sup 99m}Tc-MIBI radiopharmaceutical (radiochemical purity and pH) used in myocardial scintigraphy exam. In the case of radiochemical purity (RCP), was used the thin layer chromatography technique; after the chromatographic ran on, the plates were analyzed both in the dose calibrator, and in scintillation camera of each NMS. The radiopharmaceutical biodistribution was evaluated through the activities present in the heart and liver images in 60 patients, using the technique of combined images counting. Five nuclear physicians analyzed 24 images through myocardial perfusion visual interpretation during stress, it was verified the agreement degree among them. The results of the quality control showed that all eluate samples were in agreement with the manufacturers in relation to radionuclidic purity and pH. In relation to chemical purity, 10% of the services samples B and C showed Al{sup +3} values above 10 ppm. In the RCP, it was observed that using the scintillation camera, only 22% of the samples would be discarded, while with dose calibrator would be 78%, indicating that the scintillation camera is more sensitive in chromatographic pale analysis. For the labeled radiopharmaceutical, the services B and C presented respectively one and three samples with RCP percentage below 90%. However, C service presented the lowest medium to liver/heart proportions, showing that this factor

  9. Preparation and characterization of iron(III) {sup 99}Mo-molybdate(VI) gels for the assessment of {sup 99m}Tc elution performance

    Energy Technology Data Exchange (ETDEWEB)

    Amin, Mahmoud; Fasih, Tharwat W.; El-Absy, Mohamed A. [Egyptian Atomic Energy Authority, Cairo (Egypt)

    2018-04-01

    New iron(III) {sup 99}Mo-molybdate(VI) gels (Fe{sup 99}Mo) of high Mo content were prepared by the precipitation/filtration method. {sup 99}Mo-MoO{sub 3} dissolved in NaOH was added to aqueous solutions of Fe(NO{sub 3}){sub 3} at Mo/Fe mole fractions ∝2.21 and 1.99 with continuous stirring at ambient room temperature. Two different Fe{sup 99}Mo were precipitated from the mixed solutions adjusted at pH 2 and 4.7. The amount of water of hydration increased with the increasing the gel settling time and pH of the mixed solution. The matrices were characterized by radiometric, XRD, SEM, XRF, FT-IR, TGA, and DTA measurements. Small chromatographic columns of 2.0 g Fe{sup 99}Mo containing ≥800 mg Mo tagged with 740 MBq {sup 99}Mo were eluted with 5 mL saline solution. Highly reproducible {sup 99m}Tc elution indices suitable for preparation of {sup 99}Mo/{sup 99m}Tc generators were achieved from generator supported with 0.5 g Al{sub 2}O{sub 3} filter. Elution performance of {sup 99m}Tc radionuclide was highly dependent on the gel structural properties.

  10. Evaluation of {sup 99}Mo/{sup 99m}Tc generator columns after irradiation with different absorbed doses

    Energy Technology Data Exchange (ETDEWEB)

    Fukumori, Neuza T.O.; Mengatti, Jair; Matsuda, Margareth M.N., E-mail: ntfukumo@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNE-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    The {sup 99}Mo/{sup 99m}Tc generator is widely used in nuclear medicine and it consists of a glass column containing Teflon® strips and alumina in which {sup 99}Mo produced by {sup 235}U fission is adsorbed. The {sup 99}mTcO4- eluate shall meet the sterile and pyrogen free conditions for injectable radiopharmaceuticals as determined by the Good Manufacturing Practices. The purpose of this study was to evaluate the feasibility of using gamma radiation in the sterilization of the {sup 99}Mo/{sup 99m}Tc generator column and the influence on the elution efficiency. Alumina-containing columns were irradiated with 10, 15, 25 and 50 kGy absorbed doses. Alumina samples and control (non-irradiated) were submitted to X-ray diffraction and the combined use of scanning electron microscopy and elemental analysis. Teflon® samples were evaluated by thermogravimetry (TGA) and differential scanning calorimetry (DSC). X-ray diffractograms and micrographies with elemental analysis showed no significant changes in the crystalline structure of the alumina because it was stable α-Al{sub 2}O{sub 3}. TGA demonstrated that higher doses showed changes in lower temperatures and times than the control material. For DSC the higher the absorbed dose, the greater the polymer chain breakage and crosslinking in the material. The generator system without radioactivity was set up with the irradiated columns and the eluates demonstrated to be sterile and pyrogen free. The effects of different absorbed doses on the generator column, although some reported changes in the materials, demonstrated that the sterilization of the columns by irradiation with gamma rays as an alternative to wet heat sterilization is feasible from a technical and financial point of view. (author)

  11. Assessment of right ventricular overload using 99mTc-hexakis-methoxy-2-isobutylisonitrile (MIBI) and 123I-β-methyl iodophenyl pentadecanoic acid (BMIPP) myocardial scintigraphy

    International Nuclear Information System (INIS)

    Matsumoto, Katsushige

    2002-01-01

    Thallium-201 myocardial imaging is known to be useful for evaluating right ventricular (RV) overload. The degree of RV wall visualization has been shown to reflect RV myocardial mass and the right-to-left ventricular pressure ratio. Recently, 99m Tc-hexakis-methoxy-2-isobutylisonitrile (MIBI) and 123 I-β-methyl iodophenyl pentadecanoic acid (BMIPP) were developed and have been used to evaluate ischemic heart disease. The purpose of this study was to evaluate the RV pressure and myocardial fatty acid metabolism in the right ventricle in patients with chronic RV overloading using 99m Tc-MIBI and 123 I-BMIPP myocardial imaging. 99m Tc-MIBI myocardial scintigraphy (planar and SPECT) was performed in 76 patients with RV overloading, and 123 I-BMIPP SPECT was performed in 33 patients with RV overloading. The degree of RV wall visualization using 99m Tc-MIBI planar imaging was correlated with the elevation of RV systolic pressure. The right atrium was visualized with a high frequency in patients with RV overloading, and the degree of the right atrial wall visualization was correlated with the elevation of RV end-diastolic pressure. A count ratio of right-to-left ventricular free wall (RV/LV ratio) using 99m Tc-MIBI SPECT correlated well with a systolic pressure ratio of right-to-left ventricle (sRVp/sLVp). On the other hand, no significant correlation was found between RV/LV ratio using 123 I-BMIPP SPECT and sRVp/sLVp. For the patients with RV overloading at a RV systolic pressure of 70 mmHg or more, impaired fatty acid metabolism in the RV myocardium was noted using the quantitative analysis of 123 I-BMIPP SPECT. In conclusion, RV pressure can be evaluated by quantitative analysis using 99m Tc-MIBI myocardial scintigraphy. Myocardial metabolism in the RV wall may be impaired in patients with severe RV overloading. (author)

  12. Technetium {sup 99m}Tc Pertechnetate Brain Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Rhee, Sang Min; Park, Jin Yung; Lee, Ahn Ki; Chung, Choo Il; Hong, Chang Gi [Capital Army Hospital, ROKA, Seoul (Korea, Republic of); Rhee, Chong Heon; Koh, Chang Soon [Radiological Research Institute, Seoul (Korea, Republic of)

    1968-03-15

    Technetium {sup 99}mTc pertechnetate brain scanning were performed in 3 cases of head injury (2 chronic subdural hematomas and 1 acute epidural hematoma), 2 cases of brain abscess and 1 case of intracerebral hematoma associated with arteriovenous anomaly. In all the cases brain scintigrams showed 'hot areas.' Literatures on radioisotope scanning of intracranial lesions were briefly reviewed. With the improvement of radioisotope scanner and development of new radiopharmaceuticals brain scanning became a safe and useful screening test for diagnosis of intracranial lesions. Brain scanning can be easily performed even to a moribund patient without any discomfort and risk to the patient which are associated with cerebral angiography or pneumoencephalography. Brain scanning has been useful in diagnosis of brain tumor, brain abscess, subdural hematoma, and cerebral vascular diseases. In 80 to 90% of brain tumors positive scintigrams can be expected. Early studies were done with 203 Hg-Neohydrin or {sup 131}I-serum albumin. With these agents, however, patients receive rather much radiation to the whole body and kidneys. In 1965 Harper introduced {sup 99}mTc to reduce radiation dose to the patient and improve statistical variation in isotope scanning.

  13. DNA double-strand breaks in blood lymphocytes induced by two-day 99mTc-MIBI myocardial perfusion scintigraphy.

    Science.gov (United States)

    Rief, Matthias; Hartmann, Lisa; Geisel, Dominik; Richter, Felicitas; Brenner, Winfried; Dewey, Marc

    2018-07-01

    To investigate DNA double-strand breaks (DSBs) in blood lymphocytes induced by two-day 99m Tc-MIBI myocardial perfusion scintigraphy (MPS) using y-H2AX immunofluorescence microscopy and to correlate the results with 99m Tc activity in blood samples. Eleven patients who underwent two-day MPS were included. DSB blood sampling was performed before and 5min, 1h and 24h after the first and second radiotracer injections. 99m Tc activity was measured in each blood sample. For immunofluorescence microscopy, distinct foci representing DSBs were quantified in lymphocytes after staining for the phosphorylated histone variant y-H2AX. The 99m Tc-MIBI activity measured on days one and two was similar (254±25 and 258±27 MBq; p=0.594). Compared with baseline DSB foci (0.09±0.05/cell), a significant increase was found at 5min (0.19±0.04/cell) and 1h (0.18±0.04/cell) after the first injection and at 5min and 1h after the second injection (0.21±0.03 and 0.19±0.04/cell, respectively; p=0.003 for both). At 24h after the first and second injections, the number of DSB foci had returned to baseline (0.06±0.02 and 0.12±0.05/cell, respectively). 99m Tc activity levels in peripheral blood samples correlated well with DSB counts (r=0.451). DSB counts reflect 99m Tc-MIBI activity after injection for two-day MPS, and might allow individual monitoring of biological effects of cardiac nuclear imaging. • Myocardial perfusion scintigraphy using 99m Tc induces time-dependent double-strand breaks (DSBs) • γ-H2AX immunofluorescence microscopy shows DSB as an early response to radiotracer injection • Activity measurements of 99m Tc correlate well with detected DSB • DSB foci induced by 99m Tc return to baseline 24h after radiotracer injection.

  14. Performance tests on column materials for {sup 99}Mo-{sup 99m}Tc generator

    Energy Technology Data Exchange (ETDEWEB)

    Sombrito, E Z; Bulos, A D; Tangonan, M C [Chemistry Research Section, Atomic Research Div., Philippine Nuclear Research Inst., Quezon (Philippines)

    1998-10-01

    To meet the need of producing a {sup 99}Mo-{sup 99m}Tc generator, based on low specific activity reactor-produced {sup 99}Mo, different procedures for preparing zirconium molybdate gels were tested. Performance tests were done on molybdate gel columns prepared using the procedures developed by Vietnam and China, and recently, on a polyzirconium compound (PZC) prepared in Japan. The conditions for the batch drying of a large volume of the gel material were studied as well as the conditions in preparing a column to concentrate technetium-99m. The performance of PZC sample as column material for the generator was also evaluated. (author)

  15. Role of 99mTc-MIBI in evaluation of palpable breast lesions

    International Nuclear Information System (INIS)

    Laghari, Naeem Ahmed; Anees, Mohammad

    2004-01-01

    Full text: Breast carcinoma is the most frequently diagnosed malignancy in women with 41% of all new cases diagnosed in developing countries. Over 323,000 women in the developing countries were detected in 1990, leading to 140,000 deaths. The annual incidence of breast carcinoma among women in Pakistan accounts for 32% of all detected carcinomas and 18% of all cancer related deaths. Three years data (2000-2002) collected from Bahawalpur Institute of Nuclear Medicine and Oncology (BINO) indicated that 16.5% of the total patients were registered with carcinoma breast. To reduce the mortality associated with this disease, screening of asymptomatic women has been advocated to diagnose problems at an early stage, particularly by X-ray mammography on annual basis after the age of 50. The available imaging modalities like mammography and ultrasound lack the desired specificity to differentiate the malignant masses from benign ones; hence there is a need to search for more specific imaging tool and to save the patients from unnecessary biopsies. Technetium-99m labeled methoxy-isobutyl-isonitrile (99mTc-MIBI) is a well-known cardiac perfusion-imaging agent. After convincing reports from various parts of the world that it specifically accumulates in malignant breast masses, we carried out a study to evaluate the diagnostic performance of 99mTc-MIBI scintimammography in palpable breast lesions. Patients with palpable breast lesions were studied after obtaining informed written consent. The study was carried out as a prospective trial. A total of 42 patients with 45 palpable breast masses were included in this study. The median age was 44 years (range 19-84 years). Tc-99m-MIBI was injected in a dose of 740 MBq in dorsal pedal vein and if unsuccessful then in medial cubital vein on the opposite side of the breast, to be imaged for the lump. Planar 10 minutes images in prone lateral and in supine position with arms raised behind the head were acquired 10 minutes and 60-90 minute

  16. The application of 99Tcm-MIBI scintimammography to diagnose multidrug resistance of breast cancer

    International Nuclear Information System (INIS)

    Cheng Bing

    2002-01-01

    The author discussed the main mechanism of multidrug resistance of breast cancer tissues, and the correlation between technetium-99m sestamibi ( 99 Tc m -MIBI) breast imaging results, with the expression of drug resistance proteins P-glycoprotein and glutathione-S-transferase-π in human breast cancer. Through not all the results reported before matched each other, as a kind of a noninvasive simple functional test imaging technology in vitro, SPECT can be used to diagnose P-glycoprotein expression in breast cancer, and can be used to predict chemotherapy response

  17. Detection of coronary artery disease with exercise 99Tcm-MIBI SPECT in patients with atrial fibrillation

    International Nuclear Information System (INIS)

    Yang Minfu; Guo Xinhua; He Zuoxiang; Tou Kefei; Yang Yuejin

    2007-01-01

    Objective: To investigate the ability of exercise myocardial perfusion imaging (MPI) for detecting coronary artery disease (CAD) in patients with atrial fibrillation (AF). Methods: Fifty-eight consecutive patients with AF during symptom-limited exercise 99 Tc m -methoxyisobutylisonitrile (MIBI) SPECT imaging were retrospectively analyzed. All patients underwent coronary angiography within an interval of 90 d. Results: The overall diagnostic sensitivity, specificity and accuracy of exercise 99 Tc m -MIBI SPECT were 60% (9/15), 88% (38/43) and 81% (47/58), respectively. Among patients without valvular disease, the diagnostic sensitivity and specificity were 60% (9/15) and 96% (22/23). The diagnostic accuracy was 80% (16/20) in patients with valvular heart disease. Conclusion: In patients with AF during exercise test, exercise MPI has a moderate sensitivity and an excellent specificity in detection of CAD to those without valvular disease, and has a high diagnostic accuracy in patients with valvular heart disease. (authors)

  18. Reversal of multidrug resistance with KR-30035: evaluated with biodistribution of Tc-99m MIBI in nude mice bearing human tumor xenografts

    International Nuclear Information System (INIS)

    Kim, Jung Kyun; Lee, Jae Tae; Lee, Byung Ho

    2001-01-01

    KR-30035 (KR), a new MDR reversing agent, has been found to produce a similar degree of increased Tc-99m MIBI uptake in cultured tumor cells over-expressing mdr1 mRNA compared to verapamil (VP), with less cardiovascular effects. We assessed the MDR-reversing ability of KR in vivo, and effects of various doses of KR on MIBI uptake in nude mice bearing P-glycoprotein (P-gp) positive (+) and P-gp negative (-) human tumor xenografts. P-gp (+) HCT15/CLO2 colorectal and P-gp (-) A549 non-small cell cancer cells were inoculated in each flank of 120 nude mice (20 mice x 6 groups). Group 1 (Gr1) mice received 10mg/kg Kr i.p. 3 times (x3); Gr2, 10mg/kg VP i.p. x3; Gr3, 10mg/kg KR i.p. x2 + 25mg/kg KR i.p. x1; Gr4, 10mg/kg KR i.p. x 2 + 50mg/kg i.p. x1; Gr5, 10mg/kg Kr i.p. x2 + 25mg/kg KR i.v. x1, GrC, controls. The mice were then injected with Tc-99m MIBI and sacrificed after 10 min, 30 min, 90 min and 240 min. Tumor uptake of MIBI (TU) in each group was compared. Tu in P-gp (+) and (-)tumors were both higher in Gr1 than Gr2. Washout rate between the 10 min and 4 hours was lower in Gr5 of P-gp (+) cell (0.93) than the control. Percentage increases in Tu were higher in P-gp (+) than P-gp (-) tumors with all KR doses. Pgp (+) TU were highest at 10 min (173% of GrC) and persisted up to 240 min (144%) in Gr3. Larger doses of KR resulted in a lesser degree of increase in P-gp (+) TU at 10 min (130% in Gr4 and 117% in Gr5) and 30 min (178%, 129%), but TU increased by time up to 240 min (177%, 196%). Heart and lung uptakes were markedly increased in Gr4 and Gr5 at 10 and 3C min, likely due to cardiovascular effects. No mice died. These data further suggest that KR that has significantly lower cardiovascular toxicity than verapamil can be used as an active inhibitor of MDR. Even a relatively low dose of KR significantly increased Tc-99m MIBI uptake in P-gp (+) tumors in vivo

  19. Determination of 99Mo contamination in a nuclear medicine patient submitted to a diagnostic procedure with 99mTc

    Directory of Open Access Journals (Sweden)

    Bernardo Maranhão Dantas

    2005-10-01

    Full Text Available 99mTc is a radionuclide widely used for imaging diagnosis in nuclear medicine. In Brazil it is obtained by elution from 99Mo-99mTc generators supplied by the Nuclear Energy Research Institute (IPEN. The elution is carried out in radiopharmacy laboratories located in hospitals and clinics. Depending of the quality of the generator and conditions of use during the elution process, 99Mo can be extracted from the column of the generator, becoming a radionuclidic impurity of the eluate used for the obtention of the radiopharmaceutical to be administered to the patient. 99Mo emits high-energy photons and beta particles and its presence degrades the quality of the image and unnecessarily increases the radiation dose delivered to the patient. An in-vivo measurement technique was developed to verify the occurrence of internal contamination by 99Mo in nuclear medicine patients. Direct measurements were made in a volunteer who underwent myocardial scintigraphy with 99mTc-sestamibi. The results indicated the presence of internal contamination of the patien by 99Mot. The activity was tracked for several days, and an assessment of the radiation dose from the contaminant 99Mo was made.O 99mTc é um radionuclídeo largamente utilizado em diagnósticos por imagem em medicina nuclear. No Brasil, ele é obtido por eluição de um gerador de 99Mo-99mTc fornecido pelo IPEN. A eluição do gerador é feita nas clínicas onde se realizam os exames. Durante a eluição o 99Mo pode ser carreado da coluna, tornando-se uma impureza radionuclídica do eluato a ser utilizado para a obtenção do radiofármaco administrado ao paciente. O 99Mo emite fótons de alta energia e partículas beta, e sua presença, além de provocar degradação na qualidade da imagem do exame, aumenta desnecessariamente a dose de radiação no paciente. Assim, com o objetivo de verificar a possível ocorrência de contaminação interna por 99Mo em pacientes de medicina nuclear, foi desenvolvida

  20. Determination of the worst case for cleaning validation of equipment used in the radiopharmaceutical production of lyophilized reagents for {sup 99m}Tc labelling

    Energy Technology Data Exchange (ETDEWEB)

    Porto, Luciana Valeria Ferrari Machado; Fukumori, Neuza Taeko Okasaki; Matsuda, Margareth Mie Nakamura, E-mail: luciana.porto@anvisa.gov.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Radiofarmacia

    2016-01-15

    Cleaning validation, a requirement of the current Good Manufacturing Practices (cGMP) for Drugs, consists of documented evidence that cleaning procedures are capable of removing residues to predetermined acceptance levels. This report describes a strategy for the selection of the worst case product for the production of lyophilized reagents (LRs) for labeling with {sup 99m}Tc from the Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/Sao Paulo). The strategy is based on the calculation of a 'worst case index' that incorporates information about drug solubility, cleaning difficulty, and occupancy rate in the production line. It allowed a reduction in the required number of validations considering the possible manufacturing flow of a given product and the subsequent flow, thus facilitating the process by reducing operation time and cost. The products identified as 'worst case' were LRs PUL-TEC and MIBI-TEC. (author). (author)

  1. An exploratory study on 99mTc-RGD-BBN peptide scintimammography in the assessment of breast malignant lesions compared to 99mTc-3P4-RGD2.

    Directory of Open Access Journals (Sweden)

    Qianqian Chen

    Full Text Available This study aimed to explore the diagnostic performance of single photon emission computed tomography / computerized tomography (SPECT/CT using a new radiotracer 99mTc-RGD-BBN for breast malignant tumor compared with 99mTc-3P4-RGD2.6 female patients with breast malignant tumors diagnosed by fine needle aspiration cytology biopsy (FNAB who were scheduled to undergo surgery were included in the study. 99mTc-3P4-RGD2 and 99mTc-RGD-BBN were performed with single photon emission computed tomography (SPECT at 1 hour after intravenous injection of 299 ± 30 MBq and 293 ± 32 MBq of radiotracers respectively at separate day. The results were evaluated by the Tumor to non-Tumor ratios (T/NT. 99mTc-RGD-BBN and 99mTc-3P4-RGD2 SPECT/CT images were interpreted independently by 3 experienced nuclear medicine physicians using a 3-point scale system. All of the samples were analyzed immunohistochemically to evaluate the integrin αvβ3 and gastrin-releasing peptide receptor (GRPR expression. The safety, biodistribution and radiation dosimetry of 99mTc-RGD-BBN were also evaluated in the healthy volunteers.No serious adverse events were reported in any of the patients during the study. The effective radiation dose entirely conformed to the relevant standards. A total of 6 palpable malignant lesions were detected using 99mTc-RGD-BBN SPECT/CT with clear uptake. All malignant lesions were also detected using 99mTc-3P4-RGD2 SPECT/CT. The results showed that five malignant lesions were with clear uptake and the other one with barely an uptake. 4 malignant cases were found with both αvβ3 and GRPR expression, 1 case with only GRPR positive expression (integrin αvβ3 negative and 1 case with only integrin αvβ3 positive expression (GRPR negative.99mTc-RGD-BBN is a safe agent for detecting breast cancer. 99mTc-RGD-BBN may have the potential to make up for the deficiency of 99mTc-3P4-RGD2 in the detection of breast cancer with only GRPR positive expression (integrin

  2. Alternative chromatographic system for the quality control of lipophilic technetium-99m radiopharmaceuticals such as [{sup 99m}Tc(MIBI){sub 6}]{sup +}

    Energy Technology Data Exchange (ETDEWEB)

    Faria, D.P.; Buchpiguel, C.A.; Marques, F.L.N., E-mail: danielefaria1@gmail.com [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Faculdade de Medicina. Departamento de Radiologia. Servico de Medicina Nuclear

    2015-10-15

    Knowledge of the radiochemical purity of radiopharmaceuticals is mandatory and can be evaluated by several methods and techniques. Planar chromatography is the technique normally employed in nuclear medicine since it is simple, rapid and usually of low cost. There is no standard system for the chromatographic technique, but price, separation efficiency and short time for execution must be considered. We have studied an alternative system using common chromatographic stationary phase and alcohol or alcohol:chloroform mixtures as the mobile phase, using the lipophilic radiopharmaceutical [{sup 99m}Tc(MIBI){sub 6}]{sup +} as a model. Whatman 1 modified phase paper and absolute ethanol, Whatman 1 paper and methanol: chloroform (25:75), Whatman 3MM paper and ethanol:chloroform (25:75), and the more expensive ITLC-SG and 1-propanol: chloroform (10:90) were suitable systems for the direct determination of radiochemical purity of [{sup 99m}Tc(MIBI){sub 6}]{sup +} since impurities such as {sup 99m}Tc-reduced-hydrolyzed (RH), {sup 99m}TcO4{sup -} and [{sup 99m}Tc(cysteine){sub 2}]{sup -} complex were completely separated from the radiopharmaceutical, which moved toward the front of chromatographic systems while impurities were retained at the origin. The time required for analysis was 4 to 15 min, which is appropriate for nuclear medicine routines. (author)

  3. An experimental study on recovery of renal function using {sup 99m}Tc DMSA scintigram after percutaneous nephrostomy in unilateral hydronephrosis

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Tae Yong; Nam, Sang Hwa; Park, Jong Yeon; Kim, Byung Soo [College of Medicine, Pusan National University, Pusan (Korea, Republic of)

    1992-07-15

    Obstruction on the urinary tract eventually results in damage to the kidneys and lose of function. The questions that concern the clinician are the degree of nephron loss in that kidney and potential for recovery following the relief of obstruction. {sup 99m}Tc DMSA accumulates in tubule cells and has been proposed as a marker of the tubular mass. The authors estimated the renal uptake ratio of {sup 99m}Tc DMSA for the degree of nephron loss corresponding to duration of hydronephrosis following left ureteral ligation in 5 New Zealand white rabbits and the potential for recovery following percutaneous nephrostomy of hydronephrosis in 24 rabbits. While the renal uptake ratio of {sup 99m}Tc DMSA of the kidney with unilateral hydronephrosis following ureteral ligation reduced dramatically within 24 hour, that of the opposite healthy kidney increased, and the total renal uptake ratio was same as normal functioning kidneys before ureteral ligation. Upon ureteral release, there was no evidence of definite recovery or impairment in the experimental kidneys for 5 days. The authors conclude that a combination of ureteral release and administration of some drugs such as renal vasodilator or diuretics is an appropriate treatment for the recovery of function in unilateral hydronephrosis.

  4. Comparison of Diagnostic Accuracy for Detecting coronary Artery Disease of Dipyridamole 99mTc-MIBI Myocardial SPECT and It's Defect Map between Men and Women

    International Nuclear Information System (INIS)

    Lee, Dong Soo; Oh, Byung Hee; Chung, June Key; Lee, Myoung Mook; Park, Young Bae; Lee, Myung Chul; Seo, Jung Don; Lee, Young Woo; Koh, Chang Soon

    1993-01-01

    To evaluate the usefulness and differences in diagnosing coronary artery disease (CAD) between men and women of intravenous dipyridamole 99m Tc-MIBI myocardial SPECT, we obtained 99m Tc-MIBI myocardial SPECT and compared with the findings of coronary angiographies. Ninety eight male and 37 female patients who underwent dipyridamole 99m Tc- MIBI myocardial imaging within one month of cardiac catheterization were studied. Scans were considered abnormal if perfusion defect was detected and the defect size was more than 12% for left anterior descending artery (LAD) and circumflex(LCX) and 8% for right coronary artery (RCA) territories. Lesions ≥ 50% luminal diameter narrowing were considered significant CAD. Overall sensitivity for detection of CAD was 94.3% in men and 96.4% in women; specificity was 70% in men and 52.6% in women (P=not significant, ns). Vessel-matched sensitivity was 75.3% in men and 72.7% in women (P=ns); specificity was 84.6% in men and 67.9% in women (P 99m Tc-MIBI myocardial SPECT is a safe, noninvasive test for evaluation of CAD. There was no gender difference to detect CAD, but more false-positive rate in women especially in the territory of LAD.

  5. A neutral lipophilic complex of sup(99m)Tc with a multidentate amine oxime

    International Nuclear Information System (INIS)

    Troutner, D.E.; Volkert, W.A.; Hoffman, T.J.; Holmes, R.A.

    1984-01-01

    Propylene amine oxime, 3,3'-(1,3-propanediyldiimino)bis(3-methyl-2-butanone)dioxime, (PnAO) forms a neutral lipophilic complex with sup(99m)Tc in >95% yield at room temperature at pH 5-10. The complex can be prepared with generator produced sup(99m)Tc using 10 -5 M SnC 4 H 4 O 6 as the reducing agent at ligand concentrations as low as 3 x 10 -5 M. It is stable in saline solutions for as long as 24 h. [Sup(99m)Tc]PnAO may be useful as an imaging agent which passively diffuses across the blood brain barrier. (author)

  6. Studies on chemical effects on x-ray intensity ratios of K/sub β//K/sub α/ in nuclear decay of technetium nuclides /sup 99m/Tc, /sup 97m/Tc, and /sup 95m/Tc

    International Nuclear Information System (INIS)

    Yamoto, I.; Kaji, H.; Yoshihara, K.

    1986-01-01

    Chemical effects of characteristic x-ray intensity ratios of K/sub β//K/sub α/ were investigated for the second d-group element Tc in the decay processes /sup 99m/Tc99 Tc (two-step isomeric transition), /sup 97m/Tc → 97 Tc (one-step isomeric transition), and /sup 95m/Tc → 95 Mo (electron capture). The objective nuclides were produced by (n, γ)β - , (d, xn), and (α, xn) reactions and were chemically separated from the target materials. The x rays were measured with a pure germanium detector, and the K/sub β/ x rays were analyzed into the two components K/sup prime//sub beta1/ and K/sup //sub beta2/ using a computer program. The chemical effect of the intensity ratio was more pronounced for K/sup prime//sub beta2//K/sub α/ than for K/sup //sub beta1//K/sub α/, as expected. The effect was larger in KTcO 4 than in the other species of Tc 2 S 7 , K 2 TcCl 6 , and Tc metal. The effect in the two-step isomeric transition in /sup 99m/Tc was found to be larger than in the one-step isomeric transition in /sup 97m/Tc. The effect in the electron capture in /sup 95m/Tc (Mo x rays) was similar to that in /sup 97m/Tc although the ratio K/sub β//K/sub α/ was smaller in /sup 95m/Tc than in /sup 97m/Tc, reflecting the change of nuclear charge. The tendency of the observed chemical effect was explained by taking into account the interfering factors which involve Pauling's ionicity in chemical bonding between Tc and its counter atom

  7. External radiation dose from patients received diagnostic doses of 201 T1-Chloride and 99 Tc-MIBI

    International Nuclear Information System (INIS)

    Dadashzadeh, S.; Sattari, A.; Nasiroghli, G.A.

    2002-01-01

    Patients receiving diagnostic doses of radiopharmaceuticals become a source of contamination and exposure for those who come in contact with them, such as nuclear medicine technologists, relatives and nurses. Therefore, the measurement of external radiation dose from these patients is necessary. In this study, the dose rates at distances of 10, 50 and 100 cm from 70 patients who received diagnostic amounts of 201 T1-Chloride and 99 Tc-MIBI was measures. The results showed that the maximum external radiation dose rates for 201 T1 and 99 Tc-MIBI were 18.4 and 75.0 μ Sv.h -1 , respectively, at 5 cm distance from the patients. The average radiation dose received by nuclear medicine technologists, considering their close contact during one working day was 12.5 ± 3.4μ Sv. The highest received dose was 22.7 μSv, which was well below the acceptable dose limit

  8. Development of methodology for evaluation of {sup 99m}Tc and {sup 131}I incorporated activities during lactation; Desenvolvimento de metodologia para avaliacao da atividade de {sup 99m}Tc e {sup 131}I em lactantes

    Energy Technology Data Exchange (ETDEWEB)

    Santos, L. [Universidade Federal do Rio de Janeiro (IF/UFRJ), RJ (Brazil). Inst. de Fisica; Dantas, A.L.A.; Mesquita, S.A. [Universidade Federal do Rio de Janeiro (IF/UFRJ), RJ (Brazil). Inst. de Fisica; Oliveira, S.M.V., E-mail: adantas@ird.gov.br, E-mail: silvia@ird.gov.br [Universidade Federal do Rio de Janeiro (IF/UFRJ), RJ (Brazil). Inst. de Fisica; Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Div. de Dosimetria

    2012-07-01

    Internal contamination of babies may occur for milk ingestion or inhalation of mothers occupationally exposed to ionizing radiation with possible incorporation or mothers submitted to medical exposures during lactation. Radionuclide concentrations in the mother's milk may cause organ absorbed doses in the babies proportionally to the breast volumes. Milk analysis allow to determine activities ingested by the babies by determining the peak of mother's milk considering the decrease of the activity rate and the milk activities drunk at different time intervals. The work had the aim to develop simulators and methodology to evaluate {sup 99m}Tc and {sup 131}I in lactation, in the following steps: to prepare standard solution of contaminated milk separately with {sup 99m}Tc and {sup 131}I; to build four breast simulators (600 g and 800 g) and respective calibration for two geometries (breast and whole-body) in the Whole-Body Counter Unit in Instituto de Radioprotecao e Dosimetria. The results demonstrated the system efficiency to determine {sup 99m}Tc and {sup 131}I activities in breasts during the lactation period. The methodology for positioning in the 'breast geometry' seemed to be more efficient than the 'whole-body geometry' for different breast volumes. The experiment allows achieving better evaluation of internal dosimetry of mothers and their young children. (author)

  9. 201Tl/99mTc-MIBI SPECT to evaluate therapy effect of BNCT with BSH and BPA for malignant brain tumor

    International Nuclear Information System (INIS)

    Shibata, Yasushi; Katayama, Wataru; Yamamoto, Tetsuya; Nakai, Kei; Endo, Kiyoshi; Matsuda, Masahide; Matsushita, Akira; Matsumura, Akira

    2006-01-01

    201 Tl/ 99m Tc-MIBI SPECT are imaging modalities to evaluate the malignancy and viability of brain tumor. We reviewed these SPECT findings before and after BNCT, and evaluated the usefulness of SPECT. The study includes total 11 patients admitted in our hospital between 1999 and 2005, 8 with glioblastoma, 2 with anaplastic astrocytoma and 2 with anaplastic oligodendroglioma. SPECT was taken with multidetector SPECT at 15 minutes and 3 hours after intravenous injection of Tl 74 MBq or MIBI 740 MBq. Region of interests were set on tumor and contralateral white matter and radioactivity ratios were calculated as Tl, MIBI indexes. For patients with no residual tumor in MRI, Tl/MIBI indexes were low. For patients with large residual tumor the indexes were high. For the patients with recurrent tumor the indexes were very high. Tl/MIBI indexes before BNCT correlated with survival and progression-free period after BNCT. SPECT indexes decreased after BNCT. For 8 patients with recurrent tumor, the indexes increased. Tl and MIBI SPECT are valuable to evaluate malignancy, viability, survival and recurrence of malignant glioma in BNCT. (author)

  10. Evaluation of the influence of pH in the efficiency of the {sup 99}Mo-{sup 99m}Tc at basis of zirconium molybdate; Evaluacion de la influencia de pH en la eficiencia del generador {sup 99}Mo-{sup 99m}Tc a base de molibdato de zirconio

    Energy Technology Data Exchange (ETDEWEB)

    Diaz A, L V

    2003-07-01

    The {sup 99m}Tc are the radionuclide more used in the nuclear medicine, it is used for diagnostic and therapy, and he is commonly takes place by means of a generator {sup 99} Mo-{sup 99m}Tc, using molybdenum ({sup 99}Mo) product of the fission of the uranium, adsorbed over alumina. This generator imposes the use of high activities you specify of {sup 99} Mo, as well as of complex processes of separation of the one {sup 99} Mo, generating important quantities of radioactive waste of medium activity. As well as, the production of these generators, demands the use of reactors of great capacity that Mexico not it possesses, in such a way that, presently work is carried out a generator of {sup 99} Mo- {sup 99m} Tc, in the one which {sup 99} Mo taken place by the reaction {sup 98} Mo(n, {gamma}) {sup 99} Mo that it was part from a gel to base is used of molybdate and zirconium. It was found, therefore, to produce a generator {sup 99} Mo- {sup 99m}Tc with the help of gels of zirconium and molybdates with the same characteristics of quality and purity that those obtained by the one traditional generator and that it can be carried out under the conditions technical-economics prevailing in Mexico. Specifically, this work has been focused to the study of the effect caused by the variation of the one p H in the solutions of ZrOCl{sub 2} * 8H{sub 2}O (zirconil) and of molybdates, of the relationships molars zirconium : molybdenum (Zr:Mo), as well as the effect of the concentration variation, time of preparation and consequently p H of the ZrOCl{sub 2} * 8H{sub 2}O in the synthesis of the gel zirconium - {sup 99} molybdenum, on the efficiency of the generator and the quantity of {sup 99} Mo presents in the {sup 99m} Tc taken place by this means. The gel used for the production of {sup 99m}Tc will possess a discharge efficiency of recovery of {sup 99m}Tc and a contained first floor of pollutants, in particular smaller to 0.015% of {sup 99} Mo, main source of impurity radionuclide

  11. Evaluation of attenuation correction, scatter correction and resolution recovery in myocardial Tc-99m MIBI SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Larcos, G.; Hutton, B.F.; Farlow, D.C.; Campbell- Rodgers, N.; Gruenewald, S.M.; Lau, Y.H. [Westmead Hospital, Westmead, Sydney, NSW (Australia). Departments of Nuclear Medicine and Ultrasound and Medical Physics

    1998-06-01

    Full text: The introduction of transmission based attenuation correction (AC) has increased the diagnostic accuracy of Tc-99m MIBI myocardial perfusion SPECT. The aim of this study is to evaluate recent developments, including scatter correction (SC) and resolution recovery (RR). We reviewed 13 patients who underwent Tc-99m MIBI SPECT (two day protocol) and coronary angiography and 4 manufacturer supplied studies assigned a low pretest likelihood of coronary artery disease (CAD). Patients had a mean age of 59 years (range: 41-78). Data were reconstructed using filtered backprojection (FBP; method 1), maximum likelihood (ML) incorporating AC (method 2), ADAC software using sinogram based SC+RR followed by ML with AC (method 3) and ordered subset ML incorporating AC,SC and RR (method 4). Images were reported by two of three blinded experienced physicians using a standard semiquantitative scoring scheme. Fixed or reversible perfusion defects were considered abnormal; CAD was considered present with stenoses > 50%. Patients had normal coronary anatomy (n=9), single (n=4) or two vessel CAD (n=4) (four in each of LAD, RCA and LCX). There were no statistically significant differences for any combination. Normalcy rate = 100% for all methods. Physicians graded 3/17 (methods 2,4) and 1/17 (method 3) images as fair or poor in quality. Thus, AC or AC+SC+RR produce good quality images in most patients; there is potential for improvement in sensitivity over standard FBP with no significant change in normalcy or specificity

  12. Comparison of radionuclide thyroid angiography, Tc-99m-MIBI scintigraphy and power Doppler ultrasonography in the differential diagnosis of solitary cold thyroid nodules

    International Nuclear Information System (INIS)

    Kapucu, L.O.; Demirel, K.; Unlu, M.; Yucel, C.; Ozdemir, H.; Ayvaz, G.; Taneri, F.

    2002-01-01

    Materials and Methods: RTA (n:70), PD (n:58) and Tc-99m-MIBI (n:43) were performed in 70 patients with solitary cold thyroid nodules. Perfusion of the nodules in RTA was compared with the perfusion in the surrounding normal thyroid tissue and classified as follows: 0=avascular, 1 hypovascular; 2=euvascular; 3=hypervascular. Additionally, retention ratios (counts at 2 minutes/peak count value in the region of the nodule) were calculated. PD patterns were classified as follows: type A, perilesional vascular halo; type B, perilesional vascular halo and intralesional vascularisation, subdivided in: 1) with moderate intralesional vascularisation, homogeneous structure and regular vessel caliber and 2) with rich intralesional vascularisation, anarchical structure and winding vessel caliber and flow; type C, perilesional vascular halo with characteristic peripheral large afferent vessel characterized by winding caliber and flow. MIBI uptake in the nodules were scored for both early and delayed images as follows: 0=cold, 1=decreased; 2=equal and 3=increased uptake compared with surrounding thyroid tissue. Semiquantitative analysis was performed using a lesion to non-lesion ratio on early (ER) and delayed images (DR). Additionally, a retention index (RI) was calculated using the formula RI=(DR-ER) x 100/ER. These data were compared with the results of histolopathology. Results: Histology revealed thyroid carcinoma in 9 patients and benign nodular goiter in 61 patients. 8 of the 9 malignant nodules displayed hypervascularisation in RTA. Mean retention ratios were 0.41 (SD±0.13) in malignant nodules and 0.80 (SD±0.12) in benign nodules. There was significant difference in the retention ratios between malignant and benign lesions (p=0.001). A receiver operating characteristic analysis was performed to determine threshold levels for the differentiation of malignant from benign nodules. The specificities of RTA for hypervascular nodules with retention ratio threshold value <0

  13. Hypoxia-induced redox alterations and their correlation with 99mTc-MIBI and 99mTc-HL-91 uptake in colon cancer cells

    International Nuclear Information System (INIS)

    Abrantes, Ana Margarida; Silva Serra, Maria Elisa; Goncalves, Ana Cristina; Rio, Joana; Oliveiros, Barbara; Laranjo, Mafalda; Rocha-Gonsalves, Antonio Manuel; Sarmento-Ribeiro, Ana Bela; Filomena Botelho, Maria

    2010-01-01

    Colorectal cancer is one of the most common malignancies in the Western world and is an example of a solid tumour in which hypoxia is a common feature and develops because of the inability of the vascular system to supply adequate amounts of oxygen to growing tumours. Hypoxia effects on tumour cell biology can be detected and characterized using different methods. The use of imaging with γ-emitting radionuclides to detect hypoxic tissue was first suggested by Chapman in 1979 [N Engl J Med 301 (1979) 1429-1432]. 99m Tc-4,9-diaza-3,3,10,10-tetramethyldodecan-2,11-dione dioxime, also known as 99m Tc-HL-91, has been among the most studied hypoxia markers. The objective of this study was to correlate the uptake of 99m Tc-HL-91 and 99m Tc-MIBI in colon cancer cells under normoxic and hypoxic conditions and to compare this information with some parameters such as oxidative stress and mitochondrial dysfunction of the cells analyzed by flow cytometry. Our results show that the in vitro 99m Tc-HL-91 uptake is higher in hypoxic conditions, which is confirmed by the decreased uptake of 99m Tc-MIBI. Flow cytometry results demonstrate that hypoxic conditions used are not enough to induce cellular death, but are responsible for the alterations in the intracellular redox environment, namely, increase of ROS production, proteic pimonidazol-derived adduct formation and alteration in the mitochondrial membrane permeability. Therefore, these results confirm that 99m Tc-HL-91 is a radiopharmaceutical with favourable characteristics for detecting hypoxia.

  14. Assessment of non-typical worsening of myocardial perfusion in rest in comparison to stress in 99mTc-MIBI SPECT studies. Preliminary report

    International Nuclear Information System (INIS)

    Dabrowski, A.; Szumilak, B.; Wnuk, J.; Konieczna, S.; Teresinska, A.

    2002-01-01

    Worsening of regional rest perfusion in comparison to stress perfusion, observed in a few percentage of myocardial perfusion 99m Tc-MIBI SPECT studies, does not have an easy clinical interpretation. Also, no reports evaluating the relationship between worsening and technical SPECT study conditions are available. The goal of our study is: 1) to assess the reproducibility of this non-typical effect - by repeating the rest study on separate day after new MIBI injection; 2) to assess reproducibility of this effect in rest perfusion images performed at different time points after one MIBI injection; 3) to propose the most probable clinical explanation for this effect. Up to now, 20 patients (100 predicted altogether) with rest perfusion worsening in routine stress-rest 99m Tc-MIBI SPECT perfusion imaging were studied. The group was clinically in homogeneous (7 patients with suspected coronary artery disease (CAD), 4 patients with CAD and no myocardial infarction (MI), 8 patients after MI, and 1 patient with developmental anomaly). Within 14 days, rest study was repeated, with data acquisition performed at 1 h and 3 hrs after MIBI injection. Regional myocardial perfusion was evaluated qualitatively, in 17 segments of the LV and compared among stress and all the three rest (BAD-I, BAD-II, BAD-III) studies. In 175 segments there was perfusion worsening in at least one of the three rest studies. In the highest percentage of these segments (n=53, 30%, ), worsening was present in all rest studies. Among stress defects with perfusion worsening in BAD-I, the highest percentage (55%, ) presented worsening also in BAD-II (performed after separate injection of MIBI, but like in BAD-I also 1 h after injection), significantly lower percentage - persistent defect in BAD-II (25%, ), and some smaller percentage - transient defect in BAD-II (20%, ). In segments with perfusion worsening present in one of the rest studies, our preliminary results show: 1) the highest probability of

  15. Studies on the preparation of sup(99m)Tc labelled medical tracer compounds: pt. 4

    International Nuclear Information System (INIS)

    Kim, J.R.; Park, K.B.; Shim, H.S.

    1981-01-01

    A crude extract from a Korean native plant, Banha (Pinellia ternata), has been known to agglutinate the erythrocytes of rabbit, mouse and especially erythrocytes of leukemic patients, Sarcoma-180 cell and Ehrlich ascite cell. The Banha lectin was labelled either with 125 with 125 I by means of chloramine-T method or with sup(99m)Tc by using aqueous sodium pertechnetate (- sup(99m)Tc) solution and stannous chloride as a reducing agent. Their labelling yield was 60% and 98%, respectively. These labelled compounds were administered to mice by intraperitoneal injections and their radioactivity distributions were measured after 3 hours. The uptake of 125 I labelled compound to tissue in mice appeared in the order of kidney, pancreas, spleen, liver, blood, and stomach, but in the case of sup(99m)Tc, it appeared in the order of kidney, pancreas, stomach, liver, spleen and blood

  16. Pharmacologic stress-induced stunning: evaluation with quantitative gated SPECT

    International Nuclear Information System (INIS)

    Chun, K. A.; Cho, I. H.; Won, K. J.; Lee, H. W.

    2000-01-01

    The after-effect of pharmacologic stress (adenosine) on left ventricular (LV) function, end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (LVEF) were evaluated after pharmacologic stress with Tl-201 and 99m Tc-MIBI SPECT using an automated program in 153 subjects. The subjects were grouped as follows: 1) Tl-201 group (n=35, male 18, female 17, mean age: 58 years); normal scan (n=24), ischemia (n=8) and infarction (n=3). 2) 99m Tc-MIBI group (n=118, male 60, female 58, mean age: 62 years); normal scan (n=73), ischemia (n=20) and infarction (n=25) based on the interpretation of perfusion images. All patients were in sinus rhythm during the study. 1)Tl-201 group; In patients with ischemia (the mean time interval between injection and acquisition is 12.3 min), post-stress LVEF was significantly depressed after adenosine infusion (51.2 ± 6.3% vs 59.8± 8.2%, p 99m Tc-MIBI group; In patients with ischemia (the mean time interval between injection and acquisition is 80 min), post-stress LVEF was significantly depressed after adenosine infusion (p<0.001) and ΔLVEF was 5.1%. Eight patients (40%) showed an increase in LVEF greater than 5% from poststress to rest. Poststress ESV (37.1±17.3 ml) was significantly higher than ESV (31.3±15.5 ml, p<0.001) at rest, but no significant difference in EDV. These results showed that pharmacologic stress induced stunning is well noted in the early quantitative gated SPECT in ischemic patients and also observed in the delayed gated SPECT, even though the rate of stunning is less than the early SPECT

  17. Quantitative evaluation of bile diversion surgery utilizing /sup 99m/Tc HIDA scintigraphy

    International Nuclear Information System (INIS)

    Wickremesinghe, P.C.; Dayrit, P.Q.; Manfredi, O.L.; Fazio, R.A.; Fagel, V.L.

    1983-01-01

    This is a report of 21 patients presenting with epigastric pain, bilious vomiting, upper gastrointestinal bleeding, iron-deficiency anemia, and weight loss, who had undergone Billroth II gastrectomy from 3 to 35 yr earlier. Eighteen of 21 patients were found to have significant enterogastric reflux indices varying from 60% to 95% demonstrated by /sup 99m/Tc HIDA scintigraphy. Thirteen patients had diversion antireflux surgery in the form of a Roux-en-Y procedure, and 1 patient had a Henley loop jejunal interposition. Postoperative /sup 99m/Tc HIDA scintigraphic studies showed the enterogastric reflux indices to have decreased significantly to a range of 2%-26% (p less than 0.00001). There was marked improvement of symptoms, including correction of anemia and weight gain in those patients who had been anemic or who had sustained earlier weight loss. The enterogastric reflux indices of 10 asymptomatic control patients after Billroth II gastrectomy ranged from 4% to 45%. /sup 99m/Tc HIDA scintigraphy is useful in evaluating patients before and after bile diversion surgery, and demonstrates the quantitative decrease in enterogastric reflux after such surgery

  18. Comparison study among methodologies of planar chromatography for radiochemical control of technetium-99m; Estudo comparativo entre metodologias de cromatografia planar para controle radioquimico de radiofarmacos de tecnecio-99m

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Elisiane de Godoy

    2012-07-01

    Radiopharmaceuticals are substances that have radioisotopes in their composition. About 95% of the procedures performed in nuclear medicine use radiopharmaceuticals with diagnostic purposes, and the Lyophilized Reagents (LR) labeled with Technetium-99m ({sup 99}mTc), obtained from {sup 99}Mo/{sup 99}mTc generator, are the most one used. Quality Control represents the set of assays to be performed to assure that the product is adequate to its purpose. An important feature to be evaluated in {sup 99m}Tc radiopharmaceuticals is the radiochemical purity (% RqP) to quantify free pertechnetate ({sup 99}mTcO{sub 4}{sup -}) and technetium colloidal (99mTcO{sub 2}) mainly by paper chromatography (PC), thin layer (TLC) and High Performance Liquid Chromatography (HPLC). The objective of this work was to perform the comparison among the radiochemical control methodologies of LR labeled with {sup 99m}Tc, described in the United States Pharmacopoeia (USP) and European Pharmacopoeia (EP) and those used by IPEN. {sup 99m}TcO{sub 4}{sup -} eluate and DISIDA, DMSA, DTPA, EC, ECD, GHA, MIBI, MDP, PIRO, SAH and Sn Coloidal LR were provided by IPEN-CNEN/SP. TLC-cellulose, TLC-SG.TLC-SG reverse phase, HPTLC-cellulose, HPTLC-SG (Merck) and ITLC-SG (Pall Corporation), W1MM, W3MM, W17M e W31ET (Whatman) chromatographic plates were used. The measurement of the radioactivity was done in a Perkin Elmer Cobra D-5002 gamma counter. LR were labeled to obtain 55,0 MBq mL{sup 1} (1,5 mCi mL{sup 1}) of final radioactive concentration. The %{sup 99m}TcO{sub 4}{sup -}, %{sup 99m}TcO{sub 2} and % RqP were determined up to 4 hour labeling. From 11 LR, only EC and GHA have no radiochemical control methods in USP and EP. In USP and/or EP, DTPA, MDP, PIRO, SAH and Sn Coloidal methods use ITLC-SG; IPEN uses this chromatography plate in DISIDA, EC, ECD, GHA, PIRO, MIBI and SAH. As ITLC-SG had been out of production (recommended in 40, 70 and 41% of the USP, EP and IPEN methodologies, respectively), it was

  19. The {sup 99m}Tc generator using poly zirconium chloride (PZC)

    Energy Technology Data Exchange (ETDEWEB)

    Wan Awang, Wan Anuar; Dahalan, Rehir; Kasim, Shaaban [Medical Technology Div., Malaysian Inst. for Nuclear Technology Research (MINT), Selangor (Malaysia)

    1998-10-01

    The {sup 99m}Tc generator system has been prepared using poly zirconium chloride (PZC) to replace alumina (Al{sub 2}O{sub 3}) as a adsorbent. The Mo-98 (MoO{sub 3}) was irradiated using our 1 MW TRIGA MARK II research reactor. The amount of Mo-99 adsorbed to the PZC has been studied and the yield from the elution was about 20%. (author)

  20. The labelling of antibody anti-PBP2a with {sup 99m}Tc; Estudo de marcacao do anticorpo monoclonal anti-PBP2a com {sup 99m}Tc

    Energy Technology Data Exchange (ETDEWEB)

    Mororo, Janio da Silva

    2012-07-01

    Staphylococcus aureus is a major cause of life-threatening infections such as bacteraemia and endocarditis. Unfortunately, many strains of this bacterial species have become resistant to certain antibiotics, including methicillin and amoxicillin. These strains are known as methicillin-resistant S. aureus (MRSA). The penicillin binding protein 2a (PBP2a) is the enzyme responsible for conferring resistance p-lactams antibiotics for MRSA, being one promising molecule for therapy with mAb. However, besides the therapy, the methods of diagnosis are also inefficient because the diagnosis currently takes several days to produce a reliable result. Taking into account, the objective of this research was radiolabeling one anti-PBP2a mAb developed by Bio-Manguinhos/FioCruz-RJ, utilizing {sup 99m}Tc, for in situ diagnostic of the infectious caused by MRSA. First, anti-PBP2a mAb was reduced utilizing 2-mecaptoethanol (2-ME) for generate sulphydryl groups (-SH) and after to be labeled with {sup 99m}Tc. In this work, were utilized two techniques of direct method: Method 1, using tartrate and gentisic acid reagents, acting like transchelant and stabilizer agents, respectively; and Method 2, using one commercial kit of MDP. Besides the radiolabeling, the mAb reduced and mAb labeled with {sup 99m}Tc were submitted to immunoreactivity analysis, with SDS-PAGE non-reducing, Immunoblotting, ELISA and neutralization assay in vitro methods. The quantity produced of sulphydryl groups by mAb was satisfactory, approximately 5 per mAb, utilizing 6.500:1 of 2-ME:mAb molar ratio. The better labeling method was Method 2, with labeling yield of 73.5%, and showed a good stability after 2 hours (73.2%). The better formulation was: 0.5 mg of mAb anti- PBP2a, 10 {mu}U of MDP kit, after resuspended with 5 mL of saline, and 75.48 MBq (2.04 mCi) of {sup 99m}Tc, reacting by 15 minutes. The labeled mAb maintained the immunoreactivity, utilizing immunologic and in vitro experiments. (author)

  1. Relation between expression p-glycoprotein and the findings of the centellography with Tc-99m MIBI in patients with advanced mammary cancer

    International Nuclear Information System (INIS)

    Delgado, L; Alonso, O; Gualco, G; Vargas, C; Ortega, V; Alonso, I; Suarez, L; Nunez, M; Roca, R; Sabini, G; Muse, IM

    2004-01-01

    We have previously shown that pre-treatment tumor uptake of 99m Tc-MIBI, a transport substrate of P-glycoprotein (Pgp), is correlated to clinical response to doxorubicin-based chemotherapy in advanced breast cancer (ABC) patients. The aim of this study was to investigate the possible association between Pgp expression, MIBI uptake and clinical response to chemotherapy in breast cancer lesions. Twenty-seven lesions from 26 patients with ABC were included in the study. Pre-chemotherapy Pgp expression was investigated by immunocytochemistry. MIBI scintigraphy was performed 2-8 days prior chemotherapy. Images were acquired 10 minutes (early phase) and 60 minutes (delayed phase) post injection of 740-1110 MBq of 99m Tc-MIBI. Tumor-to-normal background tissue uptake ratios were calculated in the early (T/Be) and delayed (T/Bd) phase of the study. Both ratios were significantly higher (p< 0.05) in Pgp negative (n=21) than in Pgp positive lesions (n=6). Furthermore, both ratios were higher in responder compared to non-responder lesions (T/Be 2.2 vs 1.4; T/Bd 1.8 vs 1.4; p< 0.05). All lesions with a T/Be ratio higher than 1.5 were classified as responders. No significant association was found between Pgp expression and response to chemotherapy. We concluded that MIBI scintigraphy may predict MDR1 phenotype and response to doxorubicin-based chemotherapy in ABC. Pgp expression would not be useful for predicting chemotherapy response (Au)

  2. Development of kits for 99mTc radiopharmaceuticals for infection imaging. Report of a co-ordinated research project 2000-2003

    International Nuclear Information System (INIS)

    2004-09-01

    Infectious diseases remain a major health problem and cause of death worldwide, particularly in developing countries. Nuclear medicine imaging, because of its sensitivity, offers an attractive option for diagnosis of focal infections. This needs a reliable radiopharmaceutical that can selectively concentrate in sites of infection. Over the years 67 Ga and other radiopharmaceuticals that localize in inflammation associated with infection sites, also known as 'non-specific agents' have been used for infection imaging. However, experience has shown that an 'infection specific agent' that concentrates selectively at sites of infection and not inflammation would have several advantages. The first such agent developed more than two decades ago was 111 In-leucocytes which is still considered a 'gold standard'. Considerations of cost, availability, and superior properties for imaging make 99 mTc a better label than 111 In. 99 mTc white blood cell (WBC) was developed subsequently and used for infection imaging. However, both 111 In and 99 mTc WBCs have a number of drawbacks, in particular: each patient's blood sample has to be collected and individually radiolabelled; well-trained staff and suitable facilities for separating and labelling the patient's blood are needed; the risk of infection and cross-contamination associated with potential blood-borne microorganisms; and cost of materials. Because of these, considerable efforts have been continuously made towards developing convenient replacements for 99 mTc WBCs with limited success, 99 mTc antigranulocyte antibody being a good example. However, these radiopharmaceuticals still have many disadvantages, related to either their cost and availability or their performance. In view of the large potential for applications in patients, the development of new and improved 99 mTc labelled infection specific imaging agents was considered as a very worthwhile aim for scientific research in general and, in particular, for the

  3. Does the chocolate interfere with the radiolabelling of erythrocytes with 99 mTc?; Le chocolat interfere-t-il avec le radiomarquage des erythrocytes au 99 mTc?

    Energy Technology Data Exchange (ETDEWEB)

    Bustani, H.; Colavolpe, C.; Imbert-Joscht, I.; Moubarik, C.; Havlik, P.; Pisano, P.; Guillet, B. [Service de medecine nucleaire, CHU Nord, Marseille, (France)

    2009-05-15

    We present in this work the case of a failure of erythrocytes labelling with {sup 99m}Tc for a twenty five years old patient making the examination not interpretable. The patient reported that she drank a chocolate drink the morning before the examination. it is the first observation of a such interaction between the chocolate consumption. We do not have any explanation at this date, some compounds in the cocoa can be considered with caution. Some flavonoids (catechins and pro-cyanidins) modify the plasmatic and intra-erythrocyte oxido-reducer statute and could interact with the labelling (specific reduction of the {sup 99m}Tc pertechnetate in the middle of erythrocyte by the tin pyrophosphate. These compounds, as well as the methyl-xanthine-theobromine, seem modify the membrane permeability of erythrocytes and could interfere with the input of pyrophosphate or {sup 99m}Tc-pertechnetate in the middle of erythrocyte. these observations, in spite of preliminary ones, lead us to recommend near the patients to avoid the chocolate foods in the twenty four hours before this type of examinations. (N.C.)

  4. Development of {sup 99m}Tc extraction-recovery by solvent extraction method

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, Akihiro; Nishikata, Kaori; Izumo, Hironobu; Tsuchiya, Kunihiko; Ishihara, Masahiro [Japan Atomic Energy Agency, Oarai Research and Development Center, Oarai, Ibaraki (Japan); Tanase, Masakazu; Fujisaki, Saburo; Shiina, Takayuki; Ohta, Akio; Takeuchi, Nobuhiro [Chiyoda Technol Corp., Tokyo (Japan)

    2012-03-15

    {sup 99m}Tc is used as a radiopharmaceutical in the medical field for the diagnosis, and manufactured from {sup 99}Mo, the parent nuclide. In this study, the solvent extraction with MEK was selected, and preliminary experiments were carried out using Re instead of {sup 99m}Tc. Two tests were carried out in the experiments; the one is the Re extraction test with MEK from Re-Mo solution, the other is the Re recovery test from the Re-MEK. As to the Re extraction test, and it was clear that the Re extraction yield was more than 90%. Two kinds of Re recovery tests, which are an evaporation method using the evaporator and an adsorption/elution method using the alumina column, were carried out. As to the evaporation method, the Re concentration in the collected solution increased more than 150 times. As to the adsorption/elution method, the Re concentration increased in the eluted solution more than 20 times. (author)

  5. Use of /sup 99m/Tc diethylenetriaminepentaacetic acid for assessment of renal function in dogs with suspected renal disease

    International Nuclear Information System (INIS)

    Krawiec, D.R.; Twardock, A.R.; Badertscher, R.R. II; Daniel, G.B.; Dugan, S.J.

    1988-01-01

    The effectiveness of technetium /sup 99m/-labeled diethylenetriaminepentaacetic acid (/sup 99m/Tc DTPA) to assess renal function in 13 dogs with suspected renal disease was evaluated. Glomerular filtration rates (actual GFR) were determined on the basis of endogenous creatinine clearance. Predicted GFR were determined by using /sup 99m/Tc DTPA within 72 hours after the determination of creatinine clearance. The percentage of an IV administered dose of /sup 99m/Tc DTPA in the kidneys (percentage dose) was determined. Two equations were used to calculate predicted GFR, which were derived from previously reported linear regression analysis of inulin (In) and creatinine (Cr) GFR vs percentage dose /sup 99m/Tc DTPA in dog kidneys. The correlations of actual GFR vs predicted GFR (In) and actual GFR vs predicted GFR (Cr) were both r = 0.92. The dogs' mean actual GFR was 1.73 +/- 1.35 ml/min/kg. Their mean predicted GFR (In) and predicted GFR (Cr) were 1.92 +/- 1.42 ml/min/kg and 1.85 +/- 1.27 ml/min/kg, respectively. Therefore, /sup 99m/Tc DTPA can be used with high accuracy as an agent to predict GFR in dogs with suspected renal disease. The procedure for determining GFR by use of nuclear medicine was rapid and noninvasive and appeared to induce little stress in the animals evaluated

  6. Quantitative hepatosplenic scintiscanning. Experimental and clinical studies to determine the contents of radioactivity in liver and spleen following administration of 99mTc sulfur colloid

    International Nuclear Information System (INIS)

    Feuchtinger, T.

    1983-01-01

    Hepatosplenic scintiscans were obtained from 78 patients following administration of 99mTc sulfur colloid using a double-head scanner and subjected to quantitative analysis. It was the aim of the study to assess the practicability of quantitative scintiscanning of liver and spleen, to define the range of generally acceptable, normal values for the concentration of 99mTc sulfur colloid in liver and spleen as well as to evaluate the clinical relevance of this method. The following values were determined to be normal: 4.7±1.5 for the liver: Spleen ratio; 31±3% for the proportion of the left hepatic lobe in total liver concentration; 68.7±5.4% and 17.4±3.6% for the active contents of liver and spleen, respectively. Quantitative scintiscanning constitutes a very sensitive method to detect transformation processes in the liver that are associated with a decreased liver: Spleen ratio and an increased ratio between the left hepatic lobe and the total organ. The method is unsuitable to assess pathological accumulation of the tracer substances. The question as to whether the use of the more time-consuming procedure of quantitative scintiscanning is justified by the additional diagnostic information gained remains to be investigated in further studies. (TRV) [de

  7. Synthesis and evaluation of hydroxamamide-based tetradentate ligands as a new class of thiol-free chelating molecules for 99mTc radiopharmaceuticals.

    Science.gov (United States)

    Xu, L C; Nakayama, M; Harada, K; Nakayama, H; Tomiguchi, S; Kojima, A; Takahashi, M; Arano, Y

    1998-04-01

    Both N,N'-ethylene bis(benzohydroxamamide) [(C2(BHam)2)] and N,N'-propylene bis(benzohydroxamamide) [(C3(BHam)2)] were designed as new thiol-free chelating molecules for 99mTc radiopharmaceuticals. Synthetic procedures using oxadiazoline intermediates were developed for C2(BHam)2 and C3(BHam)2. Both C2(BHam)2 and C3(BHam)2 formed 99mTc complexes with high yields over a wide pH range (pH 3-12) at room temperature. Complexation yields of over 95% were achieved at ligand concentrations as low as 2.5 x 10(-6) M. Reversed-phase HPLC analyses indicated that both C2(BHam)2 and C3(BHam)2 formed 99mTc complexes as single species with stabilities much higher than those of 99mTc-BHam. Selective complex formation of 99mTc with the two ligands was observed in the presence of human IgG. No decomposition with low protein binding were demonstrated when the two 99mTc complexes were incubated in murine plasma. Although further structural studies are required, these findings implied that the Ham-based tetradentate ligands would serve as new chelating molecules for 99mTc radiopharmaceuticals.

  8. Perfusion scintigraphy of the hand with sup(99m)Tc labelled microspheres - an alternative to angiography in the diagnosis of peripheral perfusion disturbances

    Energy Technology Data Exchange (ETDEWEB)

    Karnahl, H M; Hedde, J P [Allgemeine Ortskrankenkasse Koeln (Germany, F.R.). Strahleninstitut

    1979-12-01

    sup(99m)Tc labelled microspheres were injected in the A. brachialis in addition to angiography of the hand in 15 patients. The hereby obtained results show good correlation between angiography and scintigraphy. The completely normal perfusion scintigram of the hand allows to dispense with angiography. The pathological scan, however, requires angiography. Perfusion scintigraphy of the hand seems to be most useful in the follow-up of therapeutic effects in perfusion disturbances.

  9. Study to modify the elution system in a sup(99m)Tc generator

    International Nuclear Information System (INIS)

    Delgado S, Baldomero.

    1979-01-01

    The sup(99m)Tc generator is a system that allows us to obtain sup(99m)Tc through the radioactive desintegration of 99 Mo, a radionuclide absorbed in an alumine chromatographic column, the sup(99m)Tc extraction is accomplished by elution and the 99 Mo remains at the column. In this work we try to modify the elution procedure of the generator. At present after eluating the generator, it must be dried with air, in order to support the column in an oxidant atmosphere to avoid the reduction of the technetiate. This reduction causes a low yield of elution, since the reduced species of the technetium can not be eluated. The drying of the column with air complicates a little the elution procedure, and we look to simplify it, the employed methods to resolve the problem were: a) adding an oxidant agent to the elution saline solution, b) adsorbing an oxidant in the alumina chromatographic column, after that the 99 Mo was settled. In the case a) the used oxidant agents were KMnO 4 , K 2 Cr 2 O 7 , NaNo 2 , etc. At concentration rates of 10 -7 M the obtained yields in high activity generators were of the 25-30%. In the case b) variable amounts of a disolution of 2.5 mg/ml of K 2 CrO 4 were adsorbed, the obtained yields in high activity generators were about 85-90%, this second procedure was better, it lets us keep the column wet and it is not necessary to dry it with air, and in this way it can be carried out more easily and efficiently the elution procedure. (author)

  10. {sup 99m}Tc Nanocoll: A radiopharmaceutical for sentinel node localisation in breast cancer-In vitro and in vivo results

    Energy Technology Data Exchange (ETDEWEB)

    Gommans, G.M.M. [Department of Nuclear Medicine, West-Fries Hospital Hoorn (Netherlands); Department of Nuclear Medicine (0030), Medical Centre Alkmaar, Wilhelminalaan 12, 1815 JD Alkmar (Netherlands)], E-mail: g.m.m.gommans@mca.nl; Gommans, E. [Department of Chemical Engineering, Twente University of Technology (Netherlands); Zant, F.M. van der [Department of Nuclear Medicine (0030), Medical Centre Alkmaar, Wilhelminalaan 12, 1815 JD Alkmar (Netherlands); Teule, G.J.J. [Department of Nuclear Medicine, University Medical Centre Maastricht (Netherlands); Schors, T.G. van der [Department of Clinical Pharmacy, West-Fries Hospital Hoorn (Netherlands); Waard, J.W.D. de [Department of Surgery, West-Fries Hospital Hoorn (Netherlands)

    2009-09-15

    This study evaluated labelling efficiency and radiochemical purity of {sup 99m}Tc colloid albumin to identify an optimal labelling protocol for sentinel node detection. Results indicate that a 72 h eluate is not recommended for high specific labelling of {sup 99m}Tc colloid albumin. Ex vivo, significantly higher count rates were reached using a 2 h eluate in vacuum or nitrogen. Labelling 26 MBq/{mu}g {sup 99m}Tc colloid albumin with a 2 h eluate under nitrogen is recommended because of the ease of labelling.

  11. Simultaneous 99mTc and 123I dual-isotope brain striatal phantom single photon emission computed tomography: validation of 99mTc-TRODAT-1 and 123I-IBZM simultaneous dopamine system brain imaging.

    Science.gov (United States)

    Kao, Pan-Fu; Wey, Shiaw-Pyng; Yang, An-Shoei

    2009-11-01

    [2[[2-[[[3-(4-chlorophenyl)-8-methyl-8-azabicyclo[3,2,1]-oct-2-yl]-methyl](2-mercaptoethyl)-amino]ethyl]amino]ethanethiolato(3-)-N2,N2',S2,S2]oxo-[1R-exo-exo)])-[99mTc]-technetium (99mTc-TRODAT-1) and 123I-iodobenzamide (123I-IBZM) are radiotracers for brain dopamine pre- and postsynaptic neuron imaging. The purpose of this study was to evaluate imaging parameters and crossed energy interference using simultaneous single photon emission computed tomography (SPECT) 99mTc and 123I data acquisition. A five-compartment brain striatal phantom was filled with 99mTc and/or 123I radioactive solutions with different striatal-to-background ratios, ranging from 3:1 to 9:1. SPECT data were acquired with energy window settings of 15% for the centered window at 140 keV for 99mTc and a 10% asymmetric window at 159 keV for 123I. The experiments were carried out using either individual (99mTc or 123I only) or both radionuclides. The striatal-to-background ratios and energy crossed interference between 99mTc and 123I were calculated. The phantom SPECT images demonstrated that the energy crossed interferences from 123I to 99mTc, and vice versa, were 22 +/- 12.4% and 0.4 +/- 1.0%, respectively. A net interference of 7.1 +/- 4.0% for the counts in the 15% centered 99mTc window can be expected from 123I and a net interference of 1.6 +/- 3.3% for the counts in the 10% asymmetric 123I window was derived from 99mTc. The correlation of striatal-to-background ratios between single isotope and simultaneous dual-isotope was excellent (R2 = 0.99). The imaging parameters used in this simultaneous dualisotope SPECT imaging could be used in future clinical practice for imaging patients with movement disorders by using 99mTc-TRODAT-1 and 123I-IBZM. The striatal-to-background ratios were not affected by the crossed interference between 99mTc and 123I.

  12. Simultaneous 99mTC and 123I Dual-Isotope Brain Striatal Phantom Single Photon Emission Computed Tomography: Validation of 99mTC-Trodat-1 and 123I-IBZM Simultaneous Dopamine System Brain Imaging

    Directory of Open Access Journals (Sweden)

    Pan-Fu Kao

    2009-11-01

    Full Text Available [2[[2-[[[3-(4-chlorophenyl-8-methyl-8-azabicyclo[3,2,1]-oct-2-yl]-methyl](2-mercaptoethylamino]ethyl]amino]ethanethiolato(3--N2,N2′,S2,S2]oxo-[1R-exo-exo]-[99mTc]-technetium (99mTc-TRODAT-1 and 123I-iodobenzamide (123I-IBZM are radiotracers for brain dopamine preand postsynaptic neuron imaging. The purpose of this study was to evaluate imaging parameters and crossed energy interference using simultaneous single photon emission computed tomography (SPECT 99mTc and 123I data acquisition. A five-compartment brain striatal phantom was filled with 99mTc and/or 123I radioactive solutions with different striatal-to-background ratios, ranging from 3:1 to 9:1. SPECT data were acquired with energy window settings of 15% for the centered window at 140 keV for 99mTc and a 10% asymmetric window at 159 keV for 123I. The experiments were carried out using either individual (99mTc or 123I only or both radionuclides. The striatal-to-background ratios and energy crossed interference between 99mTc and 123I were calculated. The phantom SPECT images demonstrated that the energy crossed interferences from 123I to 99mTc, and vice versa, were 22 ± 12.4% and 0.4 ± 1.0%, respectively. A net interference of 7.1 ± 4.0% for the counts in the 15% centered 99mTc window can be expected from 123I and a net interference of 1.6 ± 3.3% for the counts in the 10% asymmetric 123I window was derived from 99mTc. The correlation of striatal-to-background ratios between single isotope and simultaneous dual-isotope was excellent (R2 = 0.99. The imaging parameters used in this simultaneous dual-isotope SPECT imaging could be used in future clinical practice for imaging patients with movement disorders by using 99mTc-TRODAT-1 and 123I-IBZM. The striatal-to-background ratios were not affected by the crossed interference between 99mTc and 123I.

  13. Utility of Tc-99m Sestamibi scintigraphy in predicting the post-surgical recurrences in patients with osteosarcoma

    International Nuclear Information System (INIS)

    Racioppi, S.; Lastiri, J.; Pallotta, G.; Dibar, E.; Makiya, M.; Jager, V.; Montivero, M.; Muscolo, L.; Parysow, O.

    2004-01-01

    Full text: Anatomic modalities are not specific enough to evaluate local recurrences in the post-surgical follow up of patients with osteosarcoma. The purpose of this study was to assess the value of Tc-99m Sestamibi (MIBI) scans in the post-surgical follow up of patients with osteosarcoma. We analysed the results of 83 Tc-99m MIBI studies in 32 patients and compared these with other investigations like CT, MRI, X-ray, bone scans and also correlated with histopathology findings. Two independent observers evaluated all the scans. Sixteen out of 83 scans were found to be MIBI positive. Eleven of these 16 scans were confirmed as true positive (PPV 69%) and 5 false positive (FP). Scintiscans in 2 of these 5 patients were acquired early after surgery and in the long term follow up both became negative. The other 3 FP scans were labeled as pseudoarthrosis or graft fracture. Of the 67 negative scans, 64 were true negative (NPV 95%). Three were false negative, 2 of them were cases with MDR. It was concluded that MIBI whole body scan is a useful tool in the post-surgical follow up of patients with osteosarcoma, particularly to evaluate local or regional recurrences. A negative scan is highly predictive for no tumor recurrence. A negative baseline scan could be consistent with MDR gene expression. (author)

  14. Labelling of bilirubin with /sup 99m/Tc and pharmacokinetic behavior

    International Nuclear Information System (INIS)

    Kaempfer, I.; Schneider, G.; Blottner, A.; Deckart, H.; Staedtisches Klinikum Berlin-Buch

    1982-01-01

    The yield of the bilirubin labelling with /sup 99m/Tc amounted to 97%. The labelled complex has been stable for 24 hours with the pH range 2-7.5. As evidenced in animal experiments the labelled bilirubin is probably subjected to natural degradation processes. Side effects could not be noticed. A disadvantage seems to be the slow transfer of /sup 99m/Tc-bilirubin from the hepatic cell to the biliary capillary

  15. The clinical application of SPECT myocardial perfusion imaging with 99mTc-MIBI

    International Nuclear Information System (INIS)

    Dong Weiyu

    1992-01-01

    This paper reported 182 SPECT myocardial perfusion images with China made 99m Tc-MIBI and were compared with ECG and UCG. The sensitivity of SPECT in ischemic were 91.2% and was higher than ECG (74.9%)and UCG (61.8%) (P < 0.01). And its specificity, accuracy and positive predictive rate were 78.3%, 90% and 97% respectively. Besides 9 cases have reverse distribution after exercise and rest images. In some ICD patients had shown their SPECT images, the perfusion defects in exercise as well as in rest image

  16. Effects of triiodothyronine upon the 131I and sup(99m)Tc uptake by the submandibular salivary glands in A2G mice

    International Nuclear Information System (INIS)

    Houssay, A.B.; Gamper, C.H.; Curbelo, H.M.

    1977-01-01

    The organ:plasma ratios and the isotope uptake in thyroid and submandibular glands were measured at different time intervals after a tracer dose of 131 I or sup(99m)Tc. Triiodothyronine depressed markedly the isotope uptake in both glands, but the inhibition of 131 I or sup(99m)Tc uptake by the thyroids was obtained with much lower doses. Thyrotrophin, while increasing markedly the 131 I or sup(99m)Tc uptake by the thyroids, did not produce any change in the 131 I or sup(99m)Tc uptake by the submandibular glands, when given either to normal or to triiodothyronine-inhibited mice. (author)

  17. Our experience with B.A.R.C. sup(99m)Tc generator

    International Nuclear Information System (INIS)

    Padmanabhan, V.; Pandurengan, N.; Lakshmanan, A.V.

    1980-01-01

    sup(99m)Tc has been eluted from its parent 99 Mo by solvent extraction method. It is pointed out that there is considerable variation in the eluted activity in day to day practice and any administration of the isotope to the patient must be measured in an isotope calibrator. Operator dose levels have been recorded which are quite within the permissible levels. (auth.)

  18. Study of different absorbent materials for the preparation of generator systems of {sup 99}Mo - {sup 99m}Tc and {sup 188}W-{sup 188}Re

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Paula Regina Corain; Osso Junior, Joao Alberto, E-mail: paulinhacorain@usp.b, E-mail: jaosso@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2009-07-01

    Amongst some currently radioisotopes, {sup 99m}Tc and {sup 188}Re present adequate decay properties for use in Nuclear Medicine. In the current times the most diagnosis examinations are performed with {sup 99m}Tc and {sup 188}Re is one radioisotope of potential use in therapy techniques. The objective of this work consists of determining the capacity of some adsorbent materials for retention of molybdenum and tungsten, aiming the optimization of generator systems of {sup 99}Mo-{sup 99m}Tc and {sup 188}W-{sup 188}Re with suitable characteristics for application in Nuclear Medicine. Known amounts, in mass, of molybdenum and tungsten were percolated through different chromatographic columns containing different commercial adsorbent materials such as: PZC (poly-zirconium compound), acid alumina and calcinated alumina used in the routine preparation of {sup 99}Mo-{sup 99m}Tc generators at IPEN. The tungsten ({sup 188}W), as well the PZC used in this project, supplied by Russia and Japan, respectively, through the International Atomic Energy Agency (IAEA) and used without any previous preparation. Also trace amounts of {sup 99}Mo and {sup 188}W were added to the initial solutions and the generators were assembled. The {sup 99}Mo-{sup 99m}Tc generators were then eluted with known volumes of 0.9% NaCl solution every 24 hours whereas the {sup 188}W-{sup 188}Re generators were eluted every 48 hours. The eluted samples were analyzed by Gamma Spectroscopy and later submitted to quality control evaluation. The results showed that the PZC presents superior retention capacity for Mo of 97.50mg Mo/gPZC, higher than in acid and calcinated alumina, however the elution efficiency at lower pHs is not so high. With regards to the experiments carried out with {sup 188}W and alumina, it was verified that the elution efficiency of {sup 188}Re was not reproducible and the retention capacity of W was 90.23mgW/gAl{sub 2}O{sub 3} at pH 7. (author)

  19. Positive thyroid cancer scintigraphy using technetium-99m methoxyisobutylisonitrile

    International Nuclear Information System (INIS)

    Nemec, J.; Nyvltova, O.; Blazek, T.; Vlcek, P.; Racek, P.; Novak, Z.; Preiningerova, M.; Hubackova, M.; Krizova, M.; Zimak, J.; Bilek, R.

    1996-01-01

    The aim of the study was to evaluate the possibility of detecting thyroid cancer recurrences without the need for withdrawal of thyroid suppressive treatment. Upper-body or whole-body scintigraphy was performed in a group of 200 patients evaluated for differentiated thyroid cancers in 1993 and 1994 using technetium-99m sestamibi. Scans were performed 20-30 min following i.v. administration of 500 MBq of 99m Tc-methoxyisobutylisonitrile (MIBI). Bone and lung metastases were detected with very high sensitivity and specificity, with a very high predictive value of negative results and a somewhat lower predictive value of positive results. The sensitivity and specificity of findings in the neck were lower but the predictive value of negative results was high. Whole-body scans with 99m Tc-MIBI are a useful tool in the follow-up of patients with differentiated thyroid cancer, for the detection of distant metastatic lesions. (orig.)

  20. Alternative generators of the 99mTc

    International Nuclear Information System (INIS)

    Khujaev, S.

    2004-01-01

    9 9mTc is the most widely used radionuclide in nuclear medicine. 9 9mTc radionuclide is obtained from a generator, in which 9 9Mo servest as the parent radionuclide. In the generator 9 9mTc and 9 9Mo radionuclides are found in genetic balance and 9 9mTc radionuclide is chemically extracted from the system periodically. Although there already exists many ways and variants of manufacturing 9 9mTc generators, search for new variants of the 9 9Mo → 9 9mTc generator systems continue. An example is the investigations carried out with the support of the IAEA. In these research works, generators based on elution of poly molybdate gels have been developed and evaluated. These generators will be serving as alternative technologies for production of 9 9mTc radionuclide, which use 9 9Mo produced by non-fission means. It is known that in Australia and China more than 30% of 9 9mTc generators are gel-generators. The works of authors are devoted to the problem of searching new perspective materials as a column material that will serve as adsorbent. The main purpose of all the research on alternative technologies is the usage of parent radionuclide 9 9Mo that is obtained from 9 8Mo(n, γ) 9 9Mo reaction instead of as a fission product. Our work examines the possibility of reception of generators 9 9Mo → 9 9mTc using non-fission 9 9Mo that is based on insoluble salts of molybdate

  1. Comparison of 99m-Tc-MDP and 99m-Tc-MIBI whole body scans for diagnosis of widespread skeletal metastases

    International Nuclear Information System (INIS)

    Ansari, M.; Hoshiar, A.; Mortazavi, S.H.

    2002-01-01

    Skeletal metastasis is one of the most important disabling complications of the malignant diseases. As in general, the survival of patients with osteometastatic lesions is relatively long, an early diagnosis can lead to improve the patient's life, both quantitatively and qualitatively and prevent exacerbation of the disease and disabling complications. In this study 22 patients with established diagnosis of malignant disease and clinical manifestations of skeletal metastasis were evaluated both with 99 m-Tc-MIBI and 99 m-Tc-MDP whole body scans, in two separate phases. Patient's diagnosis were as following: small round cell tumor, breast carcinoma. Nasopharynx carcinoma and multiple myeloma. In the first phase of the study a whole body bone scan was performed by IV injection of 740MBq 99 m-Tc-MDP. After a period of 1 week a whole body scan carried out by 99 m-Tc-MDP for all the patients. No treatment such as radiation therapy ar chemotherapy was done in this 1 week interval. The number and intensity of the scan findings were compared visually, according to the three- phase staging, subsequently. whole body survey with 99 m-Tc-MDP in 14 out 22 patient were positive demonstrating only 44.4% of body lesions established on whole body bone scan with 99 m-Tc-MDP. The mean value of intensity of radiotracer uptake was around 1.5+ (mild to moderate ). on the other hand in 7 patients with positive 99 m-Tc-MDP scan some hidden soft tissue lesions ( mostly lymph nodes) were detected with intensity of 2+. So this study shows that whole body bone scan is preferable for detection of widespread metastasis comparing with 99 m-Tc-MDP whole body scan. the significance of 99 m-Tc-MDP scan is mainly limited to some equivocal of soft tissue lesions

  2. Myocardial imaging with 99mTc-2-methoxyisobutilisonitrile in the assessment of reperfusion after intravenous thrombolytic treatment for acute myocardial infarction

    International Nuclear Information System (INIS)

    Vattimo, A.; Favilli, R.; Bertelli, P.; Burroni, L.; Gaddi, R.; Ferretti, A.; Baldi, L.

    1989-01-01

    The effect of reperfusion with intravenous streptokinase for acute myocardial infarction (AMI) was assessed by myocardial scintigraphy in 6 patients using 99m Tc-MIBI injected before and 48 hours after the thrombolysis. All patients showed 3 to 4 segmental defects consistent for AMI in the baseline study. The post-thrombolytic study showed an intense reperfusion in 3 patients, a moderate reperfusion in 2 patients and absence of reperfusion in one patient. These findings indicate that the dual imaging strategy with 99m Tc-MIBI is an effective non-invasive technique to assess the effectiveness of reperfusion in acute myocardial infarcted areas. (orig.) [de

  3. Compensation of Cross-Contamination in Simultaneous 201Tl/99mTc Myocardial Perfusion SPECT Imaging

    Directory of Open Access Journals (Sweden)

    Faraz Kalantari

    2009-12-01

    Full Text Available Introduction: It is a common protocol to use 201Tl for the rest and 99mTc for the stress cardiac SPECT imaging. Theoretically, both types of imaging may be performed simultaneously using different energy windows for each radionuclide. However, a potential limitation is the cross-contamination of scattered photons from 99mTc and collimator X-rays into the 201Tl energy window. We used a middle energy window method to correct this cross-contamination. Material and Methods: Using NCAT, a typical software torso phantom was generated. An extremely thin line source of 99mTc activity was placed inside the cardiac region of the phantom and no activity in the other parts.  The SimSET Monte Carlo simulator was used to image the phantom in different energy windows. To find the relationship between projections in different energy windows, deconvolution theory was used. We investigated the ability of the suggested functions in three steps: Monte Carlo simulation, phantom experiment and clinical study. In the last step, SPECT images of eleven patients who had angiographic data were acquired in different energy windows. All of these images were compared by determining the contrast between a defect or left ventricle cavity and the myocardium. Results: We found a new 2D kernel which had an exponential pattern with a much higher center. This function was used for modeling 99mTc down scatter distribution from the middle window image. X-ray distribution in the 201Tl window was also modeled as the 99mTc photopeak image convolved by a Gaussian function. Significant improvements in the contrasts of the simultaneous dual 201Tl images were found in each step before and after reconstruction. In comparison with other similar methods, better results were acquired using our suggested functions. Conclusion: Our results showed contrast improvement in thallium images after correction, however, many other parameters should be evaluated for clinical approaches. There are many

  4. 99MTC Alpha-Fetoprotein: A Novel, Specific Agent for the Detection of Human Breast Cancer

    National Research Council Canada - National Science Library

    Line, Bruce

    1998-01-01

    .... We have demonstrated that technetium-99m radiolabeled human alpha-fetoprotein (99mTc AFP) localizes in human breast cancer cells in-vivo, most likely concentrating in breast cancer cells due to a specific receptor not found in normal adult breast tissue...

  5. 99MTC Alpha-Fetoprotein: A Novel, Specific Agent for the Detection of Human Breast Cancer

    National Research Council Canada - National Science Library

    Line, Bruce

    1999-01-01

    .... We have demonstrated that technetium-99m radiolabeled human alpha-fetoprotein (99mTc AFP) localizes in human breast cancer cells in-vivo, most likely concentrating in breast cancer cells due to a specific receptor not found in normal adult breast tissue...

  6. Detection of metastatic bone cancer by scintiscanning with sup(99m)Tc labelled sodium pyrophosphate

    International Nuclear Information System (INIS)

    Kromer, Bernard.

    1973-01-01

    Bone scanning with sup(99m)Tc sodium pyrophosphate was performed in 65 patients with primary neoplasms, using a gamma-camera. The scans are compared to those obtained with 85 Sr and 87 Sr. Sup(99m)Tc appears to be superior to the other two in the detection of metastatic bone lesions, mainly because of its physical characteristics (high yield of 140 KeV photons, short physical half-life). The advantages related to these characteristics are emphasized: possibility of rapid and systematic investigation of the whole skeleton using a gamma-camera; low dose irradiation of the patient which enables frequent repetitive studies to be performed [fr

  7. On the dose calculation at the cellular level and its implications for the RBE of {sup 99m}Tc and {sup 123}I

    Energy Technology Data Exchange (ETDEWEB)

    Freudenberg, R., E-mail: robert.freudenberg@uniklinikum-dresden.de; Runge, R.; Maucksch, U.; Berger, V.; Kotzerke, J. [University Hospital/Faculty of Medicine Carl Gustav Carus, Technische Universität Dresden, Department of Nuclear Medicine, Dresden, Saxony 01307 (Germany)

    2014-06-15

    Purpose: Based on the authors’ previous findings concerning the radiotoxicity of{sup 99m}Tc, the authors compared the cellular survival under the influence of this nuclide with that following exposure to the Auger electron emitter {sup 123}I. To evaluate the relative biological effectiveness (RBE) of both radionuclides, knowledge of the absorbed dose is essential. Thus, the authors present the dose calculations and discuss the results based on different models of the radionuclide distribution. Both different target volumes and the influence of the uptake kinetics were considered. Methods: Rat thyroid PC Cl3 cells in culture were incubated with either{sup 99m}Tc or {sup 123}I or were irradiated using 200 kV x-rays in the presence or absence of perchlorate. The clonogenic cell survival was measured via colony formation. In addition, the intracellular radionuclide uptake was quantified. Single-cell dose calculations were based on Monte Carlo simulations performed using Geant4. Results: Compared with external radiation using x-rays (D{sub 37} = 2.6 Gy), the radionuclides {sup 99m}Tc (D{sub 37} = 3.5 Gy), and {sup 123}I (D{sub 37} = 3.8 Gy) were less toxic in the presence of perchlorate. In the absence of perchlorate, the amount of activity a{sub 37} that was necessary to reduce the surviving fraction (SF) to 0.37 was 22.8 times lower for {sup 99m}Tc and 12.4 times lower for {sup 123}I because of the dose increase caused by intracellular radionuclide accumulation. When the cell nucleus was considered as the target for the dose calculation, the authors found a RBE of 2.18 for {sup 99m}Tc and RBE = 3.43 for {sup 123}I. Meanwhile, regarding the dose to the entire cell, RBE = 0.75 for {sup 99m}Tc and RBE = 1.87 for {sup 123}I. The dose to the entire cell was chosen as the dose criterion because of the intracellular radionuclide accumulation, which was found to occur solely in the cytoplasm. The calculated number of intracellular decays per cell was (975 ± 109) decays

  8. Quality audit programme for {sup 99m}Tc and {sup 131}I radioactivity measurements with radionuclide calibrators

    Energy Technology Data Exchange (ETDEWEB)

    Joseph, Leena [Radiation Safety Systems Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India)], E-mail: leena@barc.gov.in; Anuradha, R.; Kulkarni, D.B. [Radiation Safety Systems Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India)

    2008-06-15

    The use of radiopharmaceuticals in nuclear medicine for diagnosis and therapy has increased over the years with {sup 99m}Tc and {sup 131}I being most widely used. Quality audit programmes for radioactivity measurements of {sup 131}I have been ongoing and the 12th audit was recently conducted among seventy nuclear medicine centres (NMC) in India. An audit for the activity measurements of {sup 99m}Tc was conducted for the first time among ten NMCs in Mumbai, India. These programmes for radioactivity measurements have become very important to establish traceability of measurements to national and international standards and ensure accurate calibration of radionuclide calibrators. The results of both the audits are very encouraging. Ninety-four percent of the NMCs for {sup 131}I activity measurements were within a window of {+-}10% and for {sup 99m}Tc one NMC was deviating more than {+-}10%. The methodology adopted for the audit and results are discussed in detail in this paper.

  9. Evaluation of sup(99m)Tc labeled amino acids as radiopharmaceuticals, 4. S-substituted cysteines and N-substituted iminodiacetic acids

    Energy Technology Data Exchange (ETDEWEB)

    Karube, Yoshiharu; Maeda, Tatsuo; Ohya, Masato; Sugata, Setsuro; Kono, Akira (Kyushu Cancer Center Research Inst., Fukuoka (Japan)); Matsushima, Yoshikazu

    1982-06-01

    Sixteen sup(99m)Tc labeled ligands were evaluated as scintigraphic agents. The ligands studied were cysteine, glutathione, their S-substituted derivatives, lysine-N sup(epsilon), N sup(epsilon)-diacetic acid, glycylglycine-N,N-diacetic acid, glycylglycylglycine-N,N-diacetic acid, taurine-N,N-diacetic acid, hydrazine-N,N-diacetic acid, ethylenediamine-N,N-diacetic acid, and propylne-1,3-diamine-N/sup 1/-,N/sup 1/-diacetic acid. The ligands were labeled with sup(99m)Tc by the SnCl/sub 2/ method with more than 95% yield. The in vivo behavior of the sup(99m)Tc labeled ligands were studied in golden hamsters and dogs. The organ distribution in golden hamsters indicated clearance both by hepatobiliary and renal systems. The pancreas/blood ratios were much lower in the sup(99m)Tc ligands than in /sup 75/Se-selenomethionine. Scintigraphic studies in dogs showed that the liver and kidneys were well visualized but the accumulation by the pancreas was not sufficient for clear visualization.

  10. A new inorganic adsorbent of (n, {gamma}){sup 99}Mo for the practical {sup 99m}Tc generator

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, Y; Nishino, M [Kaken Co., Asahi, Ibaraki (Japan). Functional Materials Inst.; Ishikawa, K; Tatenuma, K; Kurosawa, K; Tanase, M; Yamabayashi, H

    1998-10-01

    Technetium-99m is used most widely in diagnostic nuclear medicine. By the milking procedure, it is normally eluted as the daughter nuclide from {sup 99}Mo adsorbed in an alumina column as a generator. Molybdenum-99 with high specific activity has been produced in large quantities from the fission of irradiated {sup 235}U. However, the production process involves the troublesome handling process of various fission products in the high radiation field and generates highly radioactive and poisonous wastes. To avoid these drawbacks, some gel generators have been proposed. They are of zirconium molybdate, zirconium molybdophosphate or titanium molybdate gel, which are able to be applied to {sup 99}Mo obtained easily by (n, {gamma}) reaction of natural Mo. However, it has become apparent that the gel has been prepared only under certain strict conditions such as concentrations and reaction temperature, and eventually the elution rate of {sup 99m}Tc was unstable because of any influences of the gel preparation conditions. We have developed and reported a new inorganic adsorbent (Polyinorganic Zirconium Compound: PZC) of {sup 99}Mo with a low specific activity obtained by (n, {gamma}) reaction to overcome the problems of gel generators above mentioned. PZC was prepared from ZrCl{sub 4} and isopropyl alcohol. The adsorbed amount of {sup 99}Mo (Mo) to PZC was about 200 mg/g-PZC, and the yield of {sup 99m}Tc was about 80%. And the breakthrough of {sup 99}Mo was less than 0.5%. In this paper, the properties of the improved PZC, performance of generators with {sup 99}Mo loaded from 0.5 to 470 MBq, and a method to reduce the breakthrough of {sup 99}Mo are described. (author)

  11. Technetium /sup 99m/Tc macroaggregated albumin lung scans. Use in chronic childhood asthma

    International Nuclear Information System (INIS)

    Hyde, J.S.; Koch, D.F.; Isenberg, P.D.; Werner, P.

    1976-01-01

    Serial roentgenograms and technetium /sub 99m/Tc macroaggregated albumin lung scans were done simultaneously in 30 bronchodilator-dependent asthmatic children and young adults during both relative remission and attacks of status asthmaticus. When chest roentgenograms showed air trapping and increased peribronchial vascular markings associated with persistent perfusion defects, the children benefited from further laboratory studies and continuous comprehensive therapy. Serial scans provided information about underperfusion that was not discernible either by roentgenograms or by usual blood gas studies. Also, lung scans are easier to obtain in children with long-standing asthma than are detailed pulmonary tests. In our study, technetium /sup 99m/Tc macroaggregated albumin scans showed persistent regional perfusion defects in 20 children with chronic asthma during relative remission and exacerbations

  12. Comparative analysis of hepatopulmonary shunt obtained from pretherapy 99mTc MAA scintigraphy and post-therapy 90Y Bremsstrahlung imaging in 90Y microsphere therapy.

    Science.gov (United States)

    Jha, Ashish Kumar A; Zade, Anand A; Rangarajan, Venkatesh; Purandare, Nilendu; Shah, Sneha A; Agrawal, Archi; Kulkarni, Suyash S; Shetty, Nitin

    2012-05-01

    (99m)Tc macroaggregate albumin (MAA) scintigraphy is routinely used to estimate the hepatopulmonary shunt (HPS) of (90)Y microspheres because of their comparable average particle sizes (20-30 µm). However, the MAA particle size can vary from 10 to 90 µm. Therefore, HPS computed from (99m)Tc MAA scintigraphy may not accurately represent the HPS of (90)Y microspheres. In view of this, the present study was undertaken to investigate the accuracy of (99m)Tc MAA scintigraphy in estimating the HPS of (90)Y microspheres. Nineteen sessions of transarterial radioembolization using (90)Y therasphere were carried out in 17 patients for hepatic malignancies (both primary and secondary). For each session of therapy, a pretherapeutic (99m)Tc MAA scintigraphy and post-therapeutic (90)Y Bremsstrahlung scintigraphy were performed. The HPSs obtained from these images were compared. The mean HPS fractions calculated from the pretherapeutic (99m)Tc MAA study and the post-therapeutic (90)Y Bremsstrahlung images were 4.77 ± 2.81 and 4.52 ± 2.5%, respectively. The coefficient of correlation (r) was 0.96. (99m)Tc MAA scintigraphy accurately predicts the HPS of (90)Y microspheres.

  13. Influence of antiseptic on the impurities in the preparation of dimercaptosuccinic labelled with {sup 99m}Tc; Influence des antiseptiques sur la presence d'impuretes dans la preparation de l'acide dimercaptosuccinique marque au 99mTc

    Energy Technology Data Exchange (ETDEWEB)

    Metaye, T.; Rosenberg, T.; Perdrisot, R. [CHU de Poitiers, Service de medecine nucleaire et biophysique, 86 (France)

    2010-07-01

    Purpose: antiseptic solutions are used to disinfect the rubber stoppers on the bottles of radiopharmaceutical. Small amounts of these solutions can pass into the bottle when the cap is pricked to inject the {sup 99m}Tc. After finding in a patient a suboptimal labelling using biseptin, we studied the effect of various antiseptics on the presence of impurities in the preparation of the dimercaptosuccinic acid labelled with {sup 99m}Tc ({sup 99m}Tc-D.M.S.A.). Conclusions: We recommend using 70% isopropanol or modified alcohol Cooper instead of biseptin to disinfect the D.M.S.A. bottles caps. (N.C.)

  14. Balloon-based adjuvant radiotherapy in breast cancer: comparison between 99mTc and HDR 192Ir

    Directory of Open Access Journals (Sweden)

    Tarcísio Passos Ribeiro de Campos

    2016-04-01

    Full Text Available Abstract Objective: To perform a comparative dosimetric analysis, based on computer simulations, of temporary balloon implants with 99mTc and balloon brachytherapy with high-dose-rate (HDR 192Ir, as boosts to radiotherapy. We hypothesized that the two techniques would produce equivalent doses under pre-established conditions of activity and exposure time. Materials and Methods: Simulations of implants with 99mTc-filled and HDR 192Ir-filled balloons were performed with the Siscodes/MCNP5, modeling in voxels a magnetic resonance imaging set related to a young female. Spatial dose rate distributions were determined. In the dosimetric analysis of the protocols, the exposure time and the level of activity required were specified. Results: The 99mTc balloon presented a weighted dose rate in the tumor bed of 0.428 cGy.h-1.mCi-1 and 0.190 cGyh-1.mCi-1 at the balloon surface and at 8-10 mm from the surface, respectively, compared with 0.499 and 0.150 cGyh-1.mCi-1, respectively, for the HDR 192Ir balloon. An exposure time of 24 hours was required for the 99mTc balloon to produce a boost of 10.14 Gy with 1.0 Ci, whereas only 24 minutes with 10.0 Ci segments were required for the HDR 192Ir balloon to produce a boost of 5.14 Gy at the same reference point, or 10.28 Gy in two 24-minutes fractions. Conclusion: Temporary 99mTc balloon implantation is an attractive option for adjuvant radiotherapy in breast cancer, because of its availability, economic viability, and similar dosimetry in comparison with the use of HDR 192Ir balloon implantation, which is the current standard in clinical practice.

  15. assessment of the clinical role of simultaneous 99mTc-MIBI and 201Tl dual-isotopic myocardial perfusion SPECT imaging in the patients wit hypertension

    International Nuclear Information System (INIS)

    Xie Wenhui; Zhang Lihua; Hu Shilong; Yang Shunfang; Zeng Jun

    2004-01-01

    Objective: To study the clinical role of Simultaneous rest technetium-99m sestamibi ( 99m Tc-MIBI) and stress thallium-201 (201Tl) Dual-isotopic myocardial perfusion SPECT imaging in the patients with hypertension. Methods: 116 patients with high blood pressure underwent simultaneous dual-isotopic myocardial perfusion SPECT imaging with 99m Tc-MIBI and 201Tl. 99m Tc-MIBI was injected at rest, 15 min later dobutamine was instilled into vein begin with 5 mg/kg/min, before and after instilling the base ECG, blood pressure, heart rate was recorded. when the maximal dose of Dobutamine was achieved, thallium-201 was injected, the dual-isotopic simultaneously SPECT imagine was performed. The stress and rest imagine was obtained. After tomographic reconstruction, the images were interpreted by two experienced observers without previous knowledge of results of other studies. Coronary angiography was performed in two weeks. All of 116 patients were found normal. Results: (1) All of 116 patients with high blood pressure were divided as three group by the course of disease: A group ( 20 year), 15. The heart/lung ratios of A, B, C group were 2.651±0.246, 2.546±0.231, 2.490±0.36 (mean±SD)respectively, no significant difference was noted among three group. Normal heart/lung ratios is 2.50±0.28 among of control group of 20. (2) The overall sensitivity for the dual-isotopic simultaneously myocardial SPECT imagine of high blood pressure was 46.55%(54/116). (3) Anterior, lateral, inferior, apex, interventricular septal segment were regarded as a whole segment, 111 segments display abnormal 201Tl uptake. 63, 30, 18 segments were in A, B, C group respectively, and no significant difference was noted among three group. 4 85 segments reveal reduced stressing 201Tl uptake and no typical redistribution was observed in the delay 201Tl imagines. 20, 24, 14, 12, 15 segments were in anterior, lateral, inferior, apex, interventricular septal segment respectively. 26 segments display

  16. In vivo/in vitro labeling of red blood cells with sup(99m)Tc and clinical applications

    International Nuclear Information System (INIS)

    Bauer, R.; Langhammer, H.; Pabst, H.W.; Bauer, U.; Sauer, E.

    1981-01-01

    A reliable and stabile in vivo/in vitro labeling technique of red blood cells (RBC) is described. The patients are injected 20% of the content of an unlabeled kit used for bone scintigraphy (TechneScan PYP, Byk-Mallinckrodt). 15 minutes later 3 ml blood are sampled in a heparinized syringe. The blood is incubated together with 30-40 mCi (1-1.5 GBq) sup(99m)Tc for 10 minutes in a water bath at 35-37 0 C. After centrifugation at 500 g a dose of 15-25 mCi (0.6-1 GBq) sup(99m)Tc labeled RBC may be withdrawn in a volume of 1-1.5 ml. Mean labeling efficiency is 88%, without using the first eluat of a Tc-generator the yield is as high as 92%. Due to the small volume, the labeled RBC may be reinjected as bolus and first pass radionuclide angiocardiography can be performed. Using labeled RBC, scintigraphy of the intravasal space is possible up to 20 hours without deterioration in contrast or accumulation of radioactivity in the extravasal space or in other organs. Evaluation of heart function can be performed up to 10 hours. In addition, labeled RBC are useful in detecting unknown gastrointestinal bleeding. (orig.) [de

  17. {sup 99m}Tc-3PRGD{sub 2} SPECT to monitor early response to neoadjuvant chemotherapy in stage II and III breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Bin; Chen, Bin; Wang, Ting; Chen, Minglong; Ji, Tiefeng; Gao, Shi; Ma, Qingjie [China-Japan Union Hospital of Jilin University, Department of Nuclear Medicine, Changchun (China); Song, Yan [China-Japan Union Hospital of Jilin University, Department of Breast Surgery, Changchun (China); Wang, Xueju [China-Japan Union Hospital of Jilin University, Department of Pathology, Changchun (China)

    2015-08-15

    Monitoring of response to neoadjuvant chemotherapy (NCT) is important for optimal management of patients with breast cancer. {sup 99m}Tc-3PRGD{sub 2} SPECT is a newly developed imaging modality for evaluating tumor vascular status. In this study, we investigated the application of {sup 99m}Tc-3PRGD{sub 2} SPECT in evaluating therapy response to NCT in patients with stage II or III breast cancer. Thirty-three patients were scheduled to undergo {sup 99m}Tc-3PRGD{sub 2} SPECT at baseline, after the first and second cycle of NCT. Four patients had extremely low {sup 99m}Tc-3PRGD{sub 2} uptake at baseline, and were not included in the subsequent studies. Changes in tumor to nontumor (T/N) ratio were compared with pathological tumor responses classified using the residual cancer burden system. Receiver operator characteristic analysis was used to compare the power to identify responders between the end of the first and the end of the second cycle of NCT. The impact of breast cancer subtype on {sup 99m}Tc-3PRGD{sub 2} uptake was evaluated. The correlation between {sup 99m}Tc-3PRGD{sub 2} uptake and pathological tumor response was also evaluated in each breast cancer subtype. Surgery was performed after four cycles of NCT and pathological analysis revealed 18 responders and 15 nonresponders. In patients with clearly visible {sup 99m}Tc-3PRGD{sub 2} uptake at baseline, the sensitivity, specificity, and negative predictive value of {sup 99m}Tc-3PRGD{sub 2} SPECT were 86.7 %, 85.7 % and 86.7 % after the first cycle of NCT, and 92.9 %, 93.3 % and 93.3 % after the second cycle, respectively. Among these patients, the HER-2-positive group demonstrated both higher T/N ratios and a greater change in T/N ratio than patients with other breast cancer subtypes (P < 0.05). A strong correlation was found between changes in T/N ratio and pathological tumor response in the HER-2-positive group (P < 0.03). {sup 99m}Tc-3PRGD{sub 2} SPECT seems to be useful for determining the pathological

  18. Confirmation of hydrazone formation in HYNIC-peptide conjugate preparation, and its hydrolysis during labeling with {sup 99m}Tc

    Energy Technology Data Exchange (ETDEWEB)

    Gandomkar, M. [Radioisotope Division, Nuclear Research Center, Atomic Energy Organization of Iran (AEOI), Tehran (Iran, Islamic Republic of)]. E-mail: msgandomkar@yahoo.com; Najafi, R. [Radioisotope Division, Nuclear Research Center, Atomic Energy Organization of Iran (AEOI), Tehran (Iran, Islamic Republic of); Shafiei, M. [Radioisotope Division, Nuclear Research Center, Atomic Energy Organization of Iran (AEOI), Tehran (Iran, Islamic Republic of); Ebrahimi, S.E.S. [Department of Medicinal Chemistry, Faculty of Pharmacy, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of)

    2007-07-15

    Because of its monodenticity, 6-hydrazinopyridine-3-carboxylic acid (HYNIC) is of interest as a bifunctional chelator for labeling peptide with {sup 99m}Tc. Here, we confirm the formation of hydrazone in HYNIC-conjugated peptide. The preparative HPLC was used to purify the HYNIC conjugated somatostatin-based peptide and the result showed two peaks, even after two consecutive purifications. Analysis of these peaks by mass spectrometry indicated the presence of hydrazone, produced during preparation conjugate. Further, we have shown that presence of hydrazone really does not matter because under {sup 99m}Tc-labeling conditions, hydrazone is hydrolyzed back to HYNIC that then chelates {sup 99m}Tc. A HYNIC-peptide conjugate freeze-dried kit was also prepared in a mildly acidic or neutral condition with a final pH of 6-7. The kit was then labeled by {sup 99m}Tc and incubated in 100 dec. C for 10 min, and a labeling yield of >95% was obtained.

  19. Evaluation of parathyroid imaging methods with 99mTc-MIBI. The comparison of planar images obtained using a pinhole collimator and a parallel-hole collimator

    International Nuclear Information System (INIS)

    Fujii, Hirofumi; Iwasaki, Ryuichiro; Hashimoto, Jun; Nakamura, Kayoko; Kunieda, Etsuo; Sanmiya, Toshikazu; Kubo, Atsushi; Ogawa, Koichi; Inagaki, Kazutoshi

    1999-01-01

    Parathyroid scintigraphy with 99m Tc-MIBI was performed using two kinds of collimators, namely, a pinhole one and a parallel-hole one, to evaluate which one was more suitable for the detection of hyperfunctioning parathyroid lesions. In the studies using 99m Tc source, the pinhole collimator showed better efficiency and spatial resolution in the distance where the parathyroid scan are actually performed. In the phantom study, the nodular activities modeling parathyroid lesions were visualized better on the images obtained using the pinhole collimator. In clinical studies for 30 patients suspicious of hyperparathyroidism, hyperfunctioning parathyroid nodules were better detected when the pinhole collimator was used. In conclusion, the pinhole collimator was thought to be more suitable for parathyroid scintigraphy with 99m Tc-MIBI than the parallel-hole collimator. (author)

  20. Evaluating microvascular obstruction after acute myocardial infarction using cardiac magnetic resonance imaging and 201-thallium and 99m-technetium pyrophosphate scintigraphy

    International Nuclear Information System (INIS)

    Onishi, Takayuki; Kobayashi, Isshi; Onishi, Yuko; Kawashima, Tomoyuki; Muramoto, Hirotaka; Nakamura, Hiroaki; Nagata, Yasutoshi; Umezawa, Shigeo; Niwa, Akihiro

    2010-01-01

    Few studies have compared the ability of cardiac magnetic resonance (CMR) with that of scintigraphy using 201-thallium (201-Tl) and 99m-technetium pyrophosphate (99m-Tc PYP) to evaluate microvascular obstructions (MOs). In the present study the relationship between the scintigraphic and CMR characteristics of MOs after acute myocardial infarction (MI) was examined. The 14 patients (age 69±8 years, 11 males) underwent 201-Tl/99m-Tc PYP single photon emission computed tomography (SPECT) 7±3 days, initial CMR 16±12 days, and follow-up CMR 193±20 days after a reperfused first acute MI. Each image was analyzed using a 17-segment model. Segmental extent of delayed enhancement (DE), wall motion (WM) and degree of 201-Tl uptake were scored in 238 segments. Of 91 MI segments, MO was recognized in 22 (25%) segments on CMR. WM was significantly better in proportion to 201-Tl uptake (P=0.01) in MO segments. All 8 MO segments with WM improvement at follow-up had 99m-Tc PYP uptake, although only 3 (21%) of 14 MO segments that did not show WM improvement at follow-up had 99m-Tc PYP uptake (P=0.001). 99m-Tc PYP and 201-Tl scintigraphy have the potential to predict WM status and improvement of the MO region after reperfused acute MI. (author)

  1. ACS labelled with sup(99m)Tc and cartilage scintigraphy

    International Nuclear Information System (INIS)

    Dupuy, J.C.; Harmand, M.F.; Blanquet, P.

    1976-01-01

    ACS, chondroitine-sulphate acid, is the principal mucopolysaccharide of cartilagineous substance. We therefore thought it of interest to label this molecule with sup(99m)Tc so as to obtain a scintigraphic image of cartilagineous formations. sup(99m)Tc-pyrophosphate and the sup(99m)Tc-polyphosphates permit simultaneous imaging of hyperactive zones in bone and cartilage. The ACS-labelling technique is based on the reduction of sup(99m)Tc-pertechnetate by the tin-II-ion. Sephadex-gel chromatography at different pH-levels was used to study labelling gain, under optimum conditions it can attain 85%. The labelled product was administered intravenously and studied in rat and rabbit. An identical biological half-life of 15 minutes was found for both species. Scintigraphes from rabbits permitted clear visualization of the epiphyses of tubular bones, intervertebral cartilage, and auricular cartilage. These encouraging results point to interesting clinical applications

  2. Biological studies on 99m Tc-methoxy isobutyl isonitrile (MIBI) in oncological models

    International Nuclear Information System (INIS)

    Faintuch, Bluma L.; Almeida, Maria Aparecida T.M. de; Carvalho, Olga G.; Araujo, Elaine B.; Muramoto, Emiko

    1995-01-01

    The scanning of solid tumors with the help of radioactive isotopes is a well-accepted procedure, useful in the diagnosis and staging of ma lignant diseases. MIBI- 99m Tc is a tracer endowed with chemical and biological properties that recommend it for various purposes it has been used in the study of myocardial perfusion, as well as in the imaging of benign and malignant lesions of lungs, thyroid and bones. Yet, there is little experience with this compounds in intraperitoneal and abdominal cancer. in the present investigation this drug was prepared and tested in two oncologic models, respectively a solid and an ascitic rat tumor. (author). 8 refs., 1 tab

  3. Direct {sup 99m}Tc labeling of Herceptin (trastuzumab) by {sup 99m}Tc(I) tricarbonyl ion

    Energy Technology Data Exchange (ETDEWEB)

    Chen, W.-J.; Yen, C.-L.; Lo, S.-T.; Chen, K.-T. [Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu 30013, Taiwan (China); Lo, J.-M. [Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu 30013, Taiwan (China)], E-mail: jmlo@mx.nthu.edu.tw

    2008-03-15

    By simply incubating Herceptin (trastuzumab) with [{sup 99m}Tc(CO){sub 3}(OH{sub 2}){sub 3}]{sup +} ion in saline, a significant yield of {sup 99m}Tc-labeled trastuzumab was found to be achievable. The effective labeling may be based on that trastuzumab is inherent with endogenous histidine group to which {sup 99m}Tc(I) tricarbonyl ion can be strongly bound. For practical {sup 99m}Tc labeling processing, trastuzumab was purified beforehand from the commercial product, Herceptin (Genentech) via size exclusion chromatography to remove the excipient, {alpha}-histidine and a high-labeled yield could be obtained by incubating the purified trastuzumab with [{sup 99m}Tc(CO){sub 3}(OH{sub 2}){sub 3}]{sup +}. Retention of bioactivity of the {sup 99m}Tc(I)-labeled trastuzumab was validated using a cell binding test.

  4. Direct elution of sup(99m)Tc complexes from neutron irradiation produced 99Mo incorporated in a MoCl2-MoBr2 mixture

    International Nuclear Information System (INIS)

    Ganzerli Valentini, M.T.; Stella, R.; Genova, N.

    1987-01-01

    A novel type of sup(99m)Tc generator, enabling radiopharmaceutical preparation without reductant addition, was prepared and tested. Neutron activated product 99 Mo, in the form of dichloride cluster, was incorporated into inactive molybdenum dichloride-dibromide mixture (MCB) that was left to settle over an activated alumina layer. Direct elution with aqueous ligands such as salicylate or iminodiacetate derivatives in the pH range 6.5-7.5 yielded chemically stable sup(99m)Tc complexes accompanied by small amounts of secondary products (mostly sup(99m)TcO - 4 ). Pentavalent oxidation state in the salicylate complex and tervalent in the iminodiacetate (IDA) and in the N-(2,6-dimethylphenylcarbamoylmethyl) iminodiacetate (HIDA) complexes were assigned to the element after comparison with reference complexes. The anion exchange version of reverse-phase HPLC was used to resolve the eluted product mixture. (author)

  5. Quality control studies of {sup 99}Mo used in {sup 99}Mo/{sup 99m}Tc generators produced at IPEN/CNEN-SP, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Said, Daphne S.; Brambilla, Tania P.; Matsuda, Margareth M.N.; Osso Junior, Joao A., E-mail: daphnesaid@usp.br, E-mail: taniabrambilla@yahoo.com.br, E-mail: mmatsuda@ipen.br, E-mail: jaosso@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    {sup 99m}Tc is the most used radionuclide in nuclear medicine. In Brazil, the {sup 99}Mo/{sup 99m}Tc generators are produced exclusively by the Center of Radiopharmacy at IPEN-CNEN/SP, by importing {sup 99}Mo from different suppliers. {sup 99}Mo (t{sub 1/2} = 66 h) is a fission product of {sup 235}U, therefore, it can be accompanied by several radioisotopes that are highly prejudicial for human health, demanding a strict quality control of this product for generators safe use. The European Pharmacopoeia established some parameters and limits that evaluate the quality of the solution of sodium [{sup 99}Mo]molybdate, that is used as raw material for generator's production. The European Pharmacopoeia also recommends some analytical methods to perform these evaluations, however, it has been observed difficulties on the implementation of these methods by the generator's producers. These difficulties are probably related to the lack of practicability of the proposed methods and the extensive list of utilized reagents. In this work some procedures of the European Pharmacopoeia's quality control method for {sup 99}Mo were evaluated. Different types of solid phase exchanger cartridges were tested for retention of {sup 99}Mo in 3 different conditions. Cartridges that presented percentages of retention higher than 90% were also tested for separation of {sup 99}Mo from possible contaminants (Ru e Te). The results shown that solid phase exchanger cartridges that presented percentages of retention of Mo higher than 90% also presented significant percentages of retention of Ru and Te. An alternative method for separation of {sup 99}Mo from {sup 131}I (other contaminant) are also proposed. (author)

  6. Thyroid nodules with indeterminate cytology: molecular imaging with 99mTc-methoxyisobutylisonitrile (MIBI) is more cost-effective than the Afirma registered gene expression classifier

    International Nuclear Information System (INIS)

    Heinzel, Alexander; Mueller, Dirk; Behrendt, Florian F.; Giovanella, Luca; Mottaghy, Felix M.; Verburg, Frederik A.

    2014-01-01

    To compare the cost-effectiveness of 99m Tc-methoxyisobutylisonitrile (MIBI) thyroid scintigraphy and the Afirma registered gene expression classifier for the assessment of cytologically indeterminate thyroid nodules. A decision tree model was used. Costs were calculated from the perspective of the German health insurance system. The robustness of the results was assessed with probabilistic sensitivity analyses using a Monte Carlo simulation. Life expectancy was 34.3 years (estimated costs per patient EUR1,459 - EUR2,224) for the MIBI scan and 34.1 years (estimated costs EUR3,560 - EUR4,071) for the molecular test. These results were confirmed by the Monte Carlo simulation. MIBI thyroid scintigraphy is more cost-effective than the gene expression classifier. (orig.)

  7. Studies of monoclonal antibodies IOR-CEA-1 and IOR-EGF/R3 labelled with {sup 99m}Tc; Estudo de marcacao dos anticorpos monoclonais IOR-CEA-1 e IOR-EGF/R3 com {sup 99m}Tc

    Energy Technology Data Exchange (ETDEWEB)

    Dias, Carla Roberta de Barros Rodrigues

    2005-07-01

    Nuclear Medicine is a speciality that uses radioisotopes for the diagnosis or treatment of diseases and it is considered one of the best tools among the diagnostic modalities for detection of cancer. {sup 99m}Tc is one of the main isotopes for labelling antibodies and in Nuclear Medicine in general, due to its adequate physical properties, availability and low cost. Labelled monoclonal antibodies have shown promising results for diagnosis and therapy of cancer and their use has brought great experimental and clinical advances in the field of oncology. The main clinical applications of immunoscintigraphy with monoclonal antibodies are staging and evaluation of tumoral reappearance. The antibodies employed in this work were: OIR-CEA-1, a murine monoclonal antibody that acts directly against CEA expressed in several neoplasia in particular those from the gastrointestinal tract (colorectal cancer) and IOR-EGF/R3, a murine monoclonal antibody that binds to the external domain of EGF-R and it has been used in the diagnosis of tumors of epithelial origin. The objectives of this work were the development and optimization of the reduction and purification processes, the radiolabelling techniques and quality control procedures (radiochemical, immunoreactivity and cystein challenge) and imaging studies of monoclonal antibodies OIR-CEA-1 and IOR-EGF/R3, using the simple, fast and efficient method of direct labelling of the antibody with {sup 99m}Tc. The final results was the definition of the best conditions for the preparation of lyophilized reactive kits of OIR-CEA-1 and IOR- EGF/R3 for an efficient diagnostic application in Nuclear Medicine. The most adequate conditions for the labelling of the antibodies were: 1.0 mg Ab, 29 {mu}L MDP, 3.0 {mu}g Sn{sup 2+}, 1 mL of {sup 99m}Tc and 30 min. reaction time. With these conditions the labelling yield was always higher than 95% and the maximum activity of {sup 99m}Tc was about 2220 MBq (60 mCi). The evidences of the efficiency and

  8. Prediction of remission in Graves` disease treated with long-term carbimazole therapy: evaluation of technetium-99m thyroid uptake and TSH concentrations as prognostic indicators

    Energy Technology Data Exchange (ETDEWEB)

    Prakash, R. [Dept. of Nuclear Medicine, Batra Hospital, New Delhi (India)

    1996-02-01

    Computerized technetium-99m thyroid uptake and thyrotropin (TSH) estimation using a sensitive immunoradiometric assay were performed at presentation and following completion of an 18-month course of antithyroid drug therapy in 45 patients with Graves` disease. All patients had increased {sup 99m}Tc thyroid uptake and subnormal TSH levels before the start of treatment. Twentytwo patients developed recurrent hyperthyroidism in a 3-year follow-up period. Of the 22 patients with relapse, 20 had had a persistently increased {sup 99m}Tc thyroid uptake at the end of the course of carbimazole treatment, whereas TSH had remained subnormal in 18 of the 22. All 23 patients who remained in remission until the end of the 3-year follow-up had had normal {sup 99m}Tc thyroid uptake following completion of antihyroid drug treatment. TSH levels had reverted to normal in 19 cases, but remained subnormal in four cases in this group at the end of treatment. The results suggest a high likelihood of relapse in patients who have persistently increased {sup 99m}Tc thyroid uptake and subnormal TSH after a full course of carbimazole treatment. Patients whose {sup 99m}Tc thyroid uptake and TSH levels have reverted to normal are likely to stay in long-term remission. Assessment of {sup 99m}Tc thyroid uptake and TSH levels following completion of carbimazole therapy for Graves` disease offers useful information regarding long-term prognosis. (orig.)

  9. [Shielding effect of clinical X-ray protector and lead glass against annihilation radiation and gamma rays of 99mTc].

    Science.gov (United States)

    Fukuda, Atsushi; Koshida, Kichiro; Yamaguchi, Ichiro; Takahashi, Masaaki; Kitabayashi, Keitarou; Matsubara, Kousuke; Noto, Kimiya; Kawabata, Chikako; Nakagawa, Hiroto

    2004-12-01

    Various pharmaceutical companies in Japan are making radioactive drugs available for positron emission tomography (PET) in hospitals without a cyclotron. With the distribution of these drugs to hospitals, medical check-ups and examinations using PET are expected to increase. However, the safety guidelines for radiation in the new deployment of PET have not been adequately improved. Therefore, we measured the shielding effect of a clinical X-ray protector and lead glass against annihilation radiation and gamma rays of (99m)Tc. We then calculated the shielding effect of a 0.25 mm lead protector, 1 mm lead, and lead glass using the EGS4 (Electron Gamma Shower Version 4) code. The shielding effects of 22-mm lead glass against annihilation radiation and gamma rays of (99m)Tc were approximately 31.5% and 93.3%, respectively. The clinical X-ray protector against annihilation radiation approximately doubled the skin-absorbed dose.

  10. NTS1-R-targeted diagnostic imaging of malignant tumors with 99mTc labeled neurotensin analogues

    International Nuclear Information System (INIS)

    Nikolopoulou, A.; Nock, B.; Maina, T.; Galanis, A.; Cordopatis, P.

    2004-01-01

    Full text: Recent studies, based on receptor radio autoradiography methods in human biopsy specimens, have demonstrated the expression of neurotensin receptors of subtype 1 (NTSI-R) at a high density in primary human cancers, such as in ductal exocrine pancreatic carcinoma, Ewing's sarcoma and meningioma. This finding provides the molecular basis for the scintigraphic detection of NTS1-R-positive tumors in patients using radiolabeled NT analogues in combination with SPECT. We synthesized two novel NT analogues based on the NT (8-13) peptide sequence - essential for interaction with the NTS1-R - and modified at the N-terminal by a covalently attached open chain tetraamine chelator for stable binding of the radionuclide. In this work, a comparative study of the new compounds in cells and animal models is presented and their suitability in the NTS1-R- targeted diagnostic imaging of malignant tumors is discussed. In particular, the tetra-amine functional analogues NT1: [N4- (a) Ala0, Dab9] NT (8-13) and NT2: [N4- (a) Ala0, Dab9, Tle12] NT (8-13) were synthesized by SPPS techniques applying Fmoc/Boc protection strategies. The ES-MS spectra of the chromatographically purified products were consistent with the expected formulae. Incorporation of the radiometal (99mTc) by the open chain tetraamine framework proceeded different at room temperature in alkaline aqueous medium using SnCl2 as reducing agent in the presence of citrate. Under the above mild conditions labelling was nearly quantitative leading to single radiopeptide species of high specific activity. During competition binding assays in human colon adenocarcinoma WiDr cell membranes, using [125I-Tyr3] NT as the radioligand, both peptide conjugates demonstrated high affinity binding to the NTS1-R with IC50s 30 and 80 pM, respectively (IC50 for native NT= 0.20 nM). Both radiopeptides showed a rapid and NTS1-R-mediated migration into the intracellular compartment of the same cells reaching a 95% internalization

  11. Labeling of human immune gamma globulin with sup(99m)Tc

    International Nuclear Information System (INIS)

    Wong, D.W.; Huang, J.T.

    1977-01-01

    Human immune serum gamma globulin and rabbit anti-Stap. aureus antibody have been successfully labeled with sup(99m)Tc at pH 7.4 with an average binding efficiency of 86 and 82%, respectively. The labeled proteins behave similarly to unlabeled gamma-globulin fraction in the normal human serum as demonstrated by protein electrophoresis. The biological half-time of sup(99m)Tc-gamma-globulin in dog has been determined to be 54 min for the fast component and 14.7 hr for a slower component. Immunological assays demonstrate no significant change in antibody activity after labeling process. (author)

  12. Chemistry of /sup 99m/Tc labeling kits

    International Nuclear Information System (INIS)

    Srivastava, S.C.; Meinken, G.; Richards, P.

    1976-01-01

    Problems have been reported with the use of kit-produced /sup 99m/Tc radiopharmaceuticals. This study was undertaken to understand the chemistry involved in various stannous kit systems. The relation between Tc, tin, and the ligands used to complex the reduced Tc was investigated. It is concluded that for reliable performance, stannous kits should be prepared so that most of the tin is kept in the usable (reducing) form; a solution would be to use minimum tin and a large excess of complexing agent. Oxidation of the Tc complex to free pertechnetate is not a major problem in most kit systems. 5 figures

  13. Utility of breast gammagraphy with technological 99mibi the diagnosis of breast disease

    International Nuclear Information System (INIS)

    Saure Sarria, Victor Manuel

    2009-01-01

    Breast cancer ranks first among causes of death in women around the world, in Cuba in 2003 the incidence was 20.3% with a mortality 15.6%. Among the complementary tests of this pathology has scan breast, in this work was to evaluate the usefulness of scintigraphy in breast cancer diagnosis, we performed an observational study where were included 66 patients admitted to hospital for cancer of Camaguey breast nodules suggestive of malignant neo proliferative process in the period from January 2004 to December 2006 were taken as a group study all women who attended the clinic at that time interval and meet the following conditions: Patients over 30 years informed consent of the study, breast tumors palpable at physical examination possibility of subsequent histological confirmation, some with questionable mammograms, dense breasts, stages I and II disease, the radiotracer was used as MIBI Tc-99, and the rectilinear scanner and computer computerized imager is A sensitivity of 95%, a specificity of 88% and predictive value 90.2% positive. Which it was concluded that breast scintigraphy is useful in diagnosis of the disease. (Author)

  14. Quantitative analysis of 99Tcm-MIBI myocardial perfusion images before and after intracoronary stenting

    International Nuclear Information System (INIS)

    Liu Liangfu; Wang Tie; Yin Chuangui; Hu Dayi; Liu Jian; Li Xinhua; Zhang Shourong; Jia Sanqing

    2001-01-01

    Objective: Assessing the value of 99 Tc m -MIBI myocardial perfusion imaging (SPECT) in selection of patients for stenting, and in evaluation of the therapeutic effects of the procedure and its value for following-up of the patients with coronary artery stents. Methods: Rest and dipyridamole stress SPECT were performed in 51 patients with coronary artery diseases and coronary artery stents one week before procedure, one week and half a year (21 cases) after procedure. The location, degree and area of blood flow deficit were quantitatively analyzed. Results: Before the procedure, 50 patients showed blood flow deficit degree >80% (the lower the percentage, the more the blood flow deficit degree), blood flow deficit area 80%, 8 (16%) patients who had been with blood flow deficit area 70% before the procedure, 10 (20%) of them one week after procedure were without any severe blood flow deficit. Their acute myocardial infarctions were significantly improved. Pre-procedure, at rest, the blood flow deficit degree was 38.05%, at one week after procedure became 57.40%, it was improved by 19.35%. The patients with blood flow deficit area of 70.75% at rest before the procedure, showed a deficit area of 55.91% one week after the procedure. Compared to pre-procedure readings, the significant improvement (P 0.05) in blood flow deficit degree and area between rest and dipyridamole stress SPECT before or one week, half a year after procedure. Conclusions: The blood flow deficit degree or area measured by SPECT were improved one week and half a year after procedure. SPECT is valuable in selection of patients for the procedure and in evaluation of the effect of the therapy and it is very useful during follow-up of the patients with intracoronary stents

  15. Radiation dose to bladder wall following the administration of sup(99m)Tc-microspheres and sup(99m)Tc-DTPA

    International Nuclear Information System (INIS)

    Smith, T.

    1981-01-01

    Castronovo et al. (Health Phys. Vol. 39, p 112, 1980) reported a method of calculating the dose to the bladder wall following administration of sup(99m)Tc human albumin microspheres (sup(99m)Tc-HAM) for lung perfusion scanning. The present note comments that (1) the dosimetry is estimated for an unusual bladder voiding schedule and no indication is given of the variation of dose to be expected with different schedules, and (2) that the method assumes linear biological excretion of the radiopharmaceutical into the bladder in any particular filling period. It is shown that whilst this is a valid approximation in the case considered, it is not a generally applicable principle. Values of bladder wall dose commitments following intravenous administration of sup(99m)Tc-HAM or sup(99m)Tc DTPA are tabulated. Values for constant voiding cycles are presented for four different bladder voiding periods between 2 and 8 hr, and for three different methods of calculation:-a method described in this paper, the linear excretion method of Castronovo et al., and the method of Snyder et al. (ORNL-4584, pp. 206-208, 1970) which allows for urine flow rate. (U.K.)

  16. 99m-Tc tetrofosmin scintigraphy vs mammography in breast cancer detection

    International Nuclear Information System (INIS)

    Jaukovic, L.J.; Spaic, R.; Markovic, S.; Stankovic, N.; Dimitrijevic, S.; Strbac, M.

    2002-01-01

    99m-Tc tetrofosmin is a widely used radiotracer for breast cancer imaging. Routine mammography ,as a method for screening breast cancer patients, might be insufficient for diagnosis, especially in patients with dense breast. Aim: The aim of this study was to compare the results of mammography (MM) and scintimammography with 99m- Tc tetrofosmin (SMM) in detection of primary breast cancer. Method: Thirty patients with breast disease were included in study. All of them had clinical investigation, MM, SMM and surgical biopsy for final histological diagnosis. An amount of 600 MBq 99m- Tc tetrofosmin was injected intravenously in the arm opposite to the side of breast lesion. Ten minutes after injection planar breast 7-minutes scans were performed in supine (anterior) and prone (left and right lateral) position. Results: Out of 30 lesion breast cancer was histologically confirmed in 20 (15 ductal invasive, two lobular, one colloid, one papillar carcinoma and one case of cyst sarcoma phylodes- malignant type.) For MM sensitivity of 80%, specificity of 60% and accuracy of 76 % were obtained. At SMM 19/ 20 malignant lesions were detected. Only one false negative result was obtained in 1.0 cm lobular infiltrative cancer, although the smallest detectable lesion measured 0.6 cm. At pathohistology ten lesions presented benign. Four false positive results (two fibroadenomas, one lipogranuloma and one case of fibrocystic disease) were observed, six true negative results in four cases with fibrocystic disease and two fibroadenomas. The overall sensitivity of scintimammography was 95%, specificity 60% and accuracy 83%. Conclusion: We concluded that sensitivity of 99m-Tc tetrofosmin scintimammography in detection of breast cancer is superior to that of mammography. Our results suggest that 99m -Tc tetrofosmin is a suitable tumor seeking agent for breast cancer imaging

  17. Occupational exposure to {sup 99m}Tc and {sup 131}I in a radiopharmacy room

    Energy Technology Data Exchange (ETDEWEB)

    Valle, Bruna P.; Cunha, Kenya Dias da; Sa, Lidia Vasconcellos de; Souza, Wanderson; Santos, Maristela; Medeiras, Geiza; Conceicao, Cirilo S. [Universidade do Estado, Nova Friburgo, RJ (Brazil). Inst. Politecnico. Dept. de Modelagem Computacional], e-mail: brunapvalle@gmail.com, e-mail: kenya@ird.gov.br, e-mail: lidia@ird.gov.br, e-mail: wander@ird.gov.br, e-mail: mstela@ird.gov.br; Abrantes, Marcio Borges de [Centro de Medicina Nuclear Guanabara, Rio de Janeiro, RJ (Brazil)], e-mail: marcioabrantes@pop.com.br

    2009-07-01

    Brazil has about 310 nuclear medicine services and 90% of these services use Molybdenum/Technetium generators to prepare several radiopharmaceuticals to diagnostics; about 70% use also {sup 131}I for diagnosis and therapy. These radionuclides are associated to compounds in liquid form and during the manipulation to prepare and administer the patient dose some radioactive airborne particle can be generated. As consequence the workers can be exposed to airborne particles in the respirable fraction containing {sup 99m}Tc and {sup 131}I. The aim of this study is develop a simple and rapid method to verify if the exhaust systems installed in the SMN are efficient in preventing the inhalation of radionuclides airborne particles by workers. In order to estimate the occupational exposure a nuclear medicine service was selected and aerosol samples were collected using personal air sampler with a cyclone. The samples were analyzed using a germanium detector system and the {sup 99m}Tc and {sup 131}I average concentrations were obtained as 16,6 {+-} 14,34 mBq/m{sup 3} and 0.72 {+-} 0.36 mBq/m{sup 3}, respectively. It was not observed a correlation among air concentration and total activity processed in laboratory. These results show that the worker inhales airborne particles containing {sup 99m}Tc and {sup 131}I. (author)

  18. Thyroid nodules with indeterminate cytology: molecular imaging with {sup 99m}Tc-methoxyisobutylisonitrile (MIBI) is more cost-effective than the Afirma registered gene expression classifier

    Energy Technology Data Exchange (ETDEWEB)

    Heinzel, Alexander [RWTH Aachen University Hospital, Department of Nuclear Medicine, Aachen, Pauwelsstrasse 30 (Germany); Institute for Neuroscience and Medicine (INM-4), Research Centre, Juelich (Germany); Mueller, Dirk [University of Cologne, Institute for Health Economics and Clinical Epidemiology, Cologne (Germany); Behrendt, Florian F. [RWTH Aachen University Hospital, Department of Nuclear Medicine, Aachen, Pauwelsstrasse 30 (Germany); Giovanella, Luca [Institute of Southern Switzerland, Department of Nuclear Medicine Oncology, Belinzona (Switzerland); Mottaghy, Felix M.; Verburg, Frederik A. [RWTH Aachen University Hospital, Department of Nuclear Medicine, Aachen, Pauwelsstrasse 30 (Germany); Maastricht University Medical Center, Department of Nuclear Medicine, Maastricht (Netherlands)

    2014-08-15

    To compare the cost-effectiveness of {sup 99m}Tc-methoxyisobutylisonitrile (MIBI) thyroid scintigraphy and the Afirma registered gene expression classifier for the assessment of cytologically indeterminate thyroid nodules. A decision tree model was used. Costs were calculated from the perspective of the German health insurance system. The robustness of the results was assessed with probabilistic sensitivity analyses using a Monte Carlo simulation. Life expectancy was 34.3 years (estimated costs per patient EUR1,459 - EUR2,224) for the MIBI scan and 34.1 years (estimated costs EUR3,560 - EUR4,071) for the molecular test. These results were confirmed by the Monte Carlo simulation. MIBI thyroid scintigraphy is more cost-effective than the gene expression classifier. (orig.)

  19. Rest delayed images on 99mTc-MIBI myocardial SPECT as a noninvasive screen for the diagnosis of vasospastic angina pectoris

    International Nuclear Information System (INIS)

    Ono, Soichi; Yamaguchi, Hiroyuki; Takayama, Shin; Kurabe, Atsushi; Heito, Takayuki

    2002-01-01

    Diagnostic usefulness of 99m Tc-hexakis-2-methoxy isobutyl isonitrile (MIBI) myocardial SPECT at rest was examined in 39 cases of coronary vasospastic angina pectoris who were diagnosed by a positive reaction to ergonovine provocation. SPECT was performed 45 minutes (early image) and 3 hours (delayed image) after the intravenous injection of approximately 600 MBq of MIBI. Decrease in accumulation was ranked by four defect scores (0: normal; 1: slight decrease; 2: moderate decrease; 3: severe decrease) and the total defect score was evaluated semiquantitatively. The washout rate between the normal area and the spasm area was also evaluated quantitatively using bull's eye. As a result, 15 cases (15/39; 38.4%) showed decreased accumulation in the early image and 27 cases (27/39; 69.2%) showed decreased accumulation in the delayed image. All of the cases which showed decreased accumulation in the early image had decreased accumulation in the delayed image as well. In 6 cases (6/34; 17.6%) showed ST wave changes during exercise ECG and 16 cases (16/34: 47%) showed decreased accumulation in the exercise myocardial SPECT. The washout rate of MIBI in the decreased accumulation area was significantly higher than that of the normal area. Of 32 ergonovine induced vasospastic area, 23 areas (72%) exhibited decreased accumulation in the delayed image for the same area. Decreased accumulation in the delayed image in MIBI was due to the enhanced washout, which, in turn, indicated declined retention of MIBI by mitochondrial membrane. In coronary vasospastic angina pectoris, spasm induced ischemia was thought to have an effect on the mitochondria. This study suggested that even with a normal exercise ECG and exercise myocardial SPECT, there's a strong possibility of coronary vasospastic angina pectoris if a decreased accumulation was found in the delayed image in the MIBI myocardial SPECT at rest. Hence, in diagnosing coronary vasospastic angina pectoris, the delayed image in the

  20. Reagent' sets for the concentration of sup(99m)Tc and sup(113m)In

    International Nuclear Information System (INIS)

    Bianco de Salas, G.N.; Arciprete, J.; Mitta, A.E.A.

    1976-10-01

    A simple technique for the concentration of the eluates from 99 Mo/sup(99m)Tc and 113 Sn/sup(113m)In generators is described. The reagents' sets provided by the C.N.E.A. for the labelling of different radiopharmaceuticals can be used by only reducing their volumes proportionally. Both concentration techniques for Tc-99m and In-113m will be supplied to users as reagents' sets. (author) [es

  1. Study of Eustachian tube drainage function with radioisotope (99m-Tc)

    International Nuclear Information System (INIS)

    Marone, S.A.M.; Miniti, A.

    1985-01-01

    The knowledge of the physiological condition of the Eustachian tube is of major significance to the understanding of the middle ear pathology as well as for the treatment of each case. This paper studies the drainage function of the Eustachian tube. The choice of the Technetium (99m-Tc) as tracer was based on its physical qualities - tracer perfectly adaptable to the detection system, pure gamma emitter, low energy and 6 hours half-life. The use of Tc-99m turns out to be a very accurate method for testing the drainage function. It is an entirely physiological method, and it produces no side effect reactions. (Auth.)

  2. In vivo regional quantitation of intrathoracic /sup 99m/Tc using SPECT: concise communication

    International Nuclear Information System (INIS)

    Osborne, D.; Jaszczak, R.; Coleman, R.E.; Greer, K.; Lischko, M.

    1982-01-01

    A whole-body single-photon emission computed tomographic system (SPECT) was used to quantitate the activities of a series of /sup 99m/Tc point sources in the dog's thorax and to evaluate attenuation of a uniform esophageal line source containing a known concentration of /sup 99m/Tc. A first-order attenuation correction and an empirically derived attenuation coefficient of 0.09 cm-1 were used in the SPECT analyses of the intrathoracic point sources. The relationship between SPECT measurements of multiple point-source activities and the same sources measured in air was linear over a range of 100 to 1000 muCi (slope 1.08; R2 coefficient of determination 0.97). These data are sufficiently accurate to allow an estimate of the regional activity of radiopharmaceutical in the dog's thorax and justify their use in experimental quantitation of regional pulmonary perfusion

  3. Cardiac amyloidosis detection with pyrophosphate-99mTc scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Souza, D.S.F.; Ichiki, W.A.; Coura Filho, G.B.; Izaki, M.; Giorgi, M.C.P.; Soares Junior, J; Meneghetti, J.C. [Universidade de Sao Paulo (FM/USP), SP (Brazil). Fac. de Medicina. Instituto do Coracao. Servico de Medicina Nuclear e Imagem Molecular

    2008-07-01

    Full text: Introduction: Amyloidosis is a rare disease, characterized by extracellular deposition of insoluble amyloid fibrils in organs and tissues. It may affect virtually any system, preferably heart, kidneys and liver. The cardiac involvement produces a spectrum of clinical features, usually with progressive dysfunction. Early diagnosis is important for institution of appropriate therapy. Case report: Male patient, 75 years old, with diagnosed congestive heart failure functional class III and Mobitz II second-degree atrial-ventricular block, was hospitalized for implantation of definitive cardiac pacemaker. Patient mentioned history of worsening effort dyspnoea over a one-month period, progressing to minimum effort, orthopnea, paroxysmal nocturnal dyspnoea and paroxysms of dry cough, and swelling of lower limbs. Echocardiography showed diffuse hypertrophy of left ventricle (LV), with systolic dysfunction due to diffuse hypokinesia and hyperrefringent aspect in the septum. It was questioned a cardiac infiltrating process. Cardiac amyloidosis was considered as a diagnostic hypothesis. The patient underwent a pyrophosphate-{sup 99m}Tc scintigraphy, which showed abnormal tracer uptake in the heart projection, with diffuse pattern on the left ventricle walls, compatible with the clinical suspicion cardiac amyloidosis, which was later confirmed by endomyocardial biopsy. Discussion: In this case report, the patient had clinical and other auxiliary examinations, such as electrocardiography and Doppler echocardiography, compatible with cardiac amyloidosis, which led to implementation with pyrophosphate-{sup 99m}Tc scintigraphy and later endomyocardial biopsy. Cardiac amyloidosis occurs in about half the cases of primary amyloidosis (AL) and is rare in secondary amyloidosis (AA). Its clinical presentation is polymorphic and it can be classified into four distinctive types: restrictive cardiomyopathy, systolic dysfunction, postural hypotension and conduction disorders

  4. Estimation in adults of the glomerular filtration rate in [99mTc] DTPA renography - the rate constant method

    International Nuclear Information System (INIS)

    Carlsen, Ove

    2004-01-01

    The purpose of this study was to design an alternative and robust method for estimation of glomerular filtration rate (GFR) in [ 99 mTc]-diethylenetriaminepentaacetic acid ([ 99 mTc] -DTPA renography with a reliability not significantly lower than that of the conventional Gates' method. Methods: The method is based on renographies lasting 40 min in which regions of interest (ROIs) are manually created over selected parts of certain blood pools (e.g. heart, lungs, spleen, and liver). For each ROI the corresponding time-activity curve (TAC) was generated, decay corrected and exposed to a monoexponential fit in the time interval 10 to 40 min postinjection. The rate constant in min-1 of the monoexponential fit was denoted BETA. Following an iterative procedure comprising usually 5-10 manually created ROIs, the monoexponential fit with the maximum rate constant (BETA max ) was used for estimation of GFR. Results: In a patient material of 54 adult subjects in whom GFR was determined with multiple or one sample techniques with [ 51 Cr]-ethylenediaminetetraacetic acid ([ 51 Cr]-EDTA) the regression curve of standard GFR (GFR std ) (i.e. GFR adjusted to 1.73 m 2 body surface area) showed a close, non-linear relationship with BETA max with a correlation coefficient of 95%. The standard errors of estimate (SEE) were 6.6, 10.6 and 16.8 for GFR std equal to 30, 60, and 120 ml/(min .73 m 2 ), respectively. The corresponding SEE values for almost the same patient material using Gates' method were 8.4, 11.9, and 16.8 ml/(min 1.73 m 2 ). Conclusions: The alternative rate constant method yields estimates of GFR std with SEE values equal to or slightly smaller than in Gates' method. The two methods provide statistically uncorrelated estimates of GFR std . Therefore, pooled estimates of GFR std can be calculated with SEE values approximately 1.41 times smaller than those mentioned above. The reliabilities of the pooled estimate of GFR std separately and of the multiple samples method

  5. Optimizing labeling conditions for cysteine-based peptides with {sup 99m}Tc

    Energy Technology Data Exchange (ETDEWEB)

    Sabahnoo, Hamideh; Hosseinimehr, Seyed Jalal, E-mail: sjhosseinim@yahoo.com [Department of Radiopharmacy, Faculty of Pharmacy, Pharmaceutical Sciences Research Center, Mazandaran University of Medical Sciences, Sari (Iran, Islamic Republic of)

    2016-07-01

    Radiolabelled peptides have attracted a great deal of attention due to their wide applicability in the development of target-specific radiopharmaceuticals. They can easily be used in diagnostic imaging as carriers for the delivery of radionuclides to tumors as well as for therapy. Previous investigations revealed that technetium(V) could form stable complexes with peptide-based ligands of N{sub 3}S type such as Cys-Gly-Gly-Gly. Herein, a targeting HER-2 receptor peptide was labeled with technetium-{sup 99m} ({sup 99m}Tc) with two different types of tetrapeptide-based ligands, Cys-Gly-Gly-Gly and Cys-Ser-Ser-Ser. The effect of experimental parameters in the labeling procedure such as type of buffer solutions, pH of media, and type of exchange ligands were optimized toward obtaining maximum labeling yield. The optimum labeling conditions were different for two peptides. Shelf life of both labeled peptides was determined by analytical reversed-phase high-performance liquid chromatography (RP-HPLC) and thin layer chromatography (TLC) that showed radiochemical yield up to 95% even after 4 h. (author)

  6. Dual-phase 99mTc-MIBI imaging and the expressions of P-gp, GST-π, and MRP1 in hyperparathyroidism.

    Science.gov (United States)

    Xue, Jianjun; Liu, Yan; Yang, Danrong; Yu, Yan; Geng, Qianqian; Ji, Ting; Yang, Lulu; Wang, Qi; Wang, Yuanbo; Lu, Xueni; Yang, Aimin

    2017-10-01

    The aim of this study was to further elucidate the mechanisms of dual-phase technetium-99m methoxyisobutylisonitrile (Tc-MIBI) parathyroid imaging by exploring the association between early uptake results (EUR), delayed uptake results (DUR), and the retention index (RI) in dual-phase Tc-MIBI parathyroid imaging and P glycoprotein (P-gp), multidrug resistance-associated protein 1 (MRP1), and glutathione S-transferase-π (GST-π) expression in hyperparathyroidism (HPT). Preoperative dual-phase (early and delayed) Tc-MIBI imaging was performed on 74 patients undergoing parathyroidectomy for HPT. EUR, DUR, and RI were calculated. P-gp, MRP1, and GST-π expressions were assessed using immunohistochemistry in resected tissue from HPT and control patients. The association between P-gp, MRP1, and GST-π expressions and EUR, DUR, and RI in HPT was evaluated. The positive rate of dual-phase T c-MIBI imaging was 91.89% (68/74) and the false-negative rate was 8.11% (6/74). P-gp and GST-π expressions were higher in tissues resected from control compared with HPT patients (47.37 and 81.5%, P<0.05); there was no difference in MRP1. EUR were associated with P-gp and GST-π expressions, and DUR were associated with MRP1 expression. There was a significant difference in MRP1 expression between RI greater than or equal to 0 and RI less than 0. There was no relationship between the sensitivity of dual-phase Tc-MIBI imaging and P-gp, MRP1, and GST-π expressions in resected parathyroid tissue. The six false-negative HPT cases consisted of three P-gp (-)/MRP1 (-) tissues, three P-gp (-)/GST-π (-) tissues, and four MRP1 (-)/GST-π (-) tissues. As P-gp and GST-π expressions were higher in tissues resected from control compared with HPT patients, Tc-MIBI may wash out faster from normal parathyroid tissue surrounding the lesion compared with the lesion itself, facilitating detection.

  7. The effect of water on the extra-cardiac background on Tc-99m MIBI myocardial scintigraphy

    International Nuclear Information System (INIS)

    Nolan, L.; Bouma, H.M.; Ellmann, A.

    2004-01-01

    Full text: Introduction Tc-99m MIBI (methoxy isobutyl isonitrile) scintigraphy of the heart provides information on myocardial perfusion. Stress and rest myocardial perfusion imaging is performed on patients with suspected ischaemic heart disease. Tc-99m MIBI is concentrated by the liver and excreted into the gastro intestinal tract. Interfering hepatic and intestinal activity complicates the interpretation of myocardial perfusion in the inferior wall. The intake of a fatty meal after administration of the radiopharmaceutical decreases hepatic activity but often increases intestinal activity. A simple, cheap method to decrease hepatic and intestinal activity will help to optimise the diagnostic evaluation of abnormalities in the inferior wall of the heart. Aim: The purpose of the study Is to investigate the volume effect of a full stomach induced by 400ml of water on the appearance of intestinal artifacts on stress-rest Tc-99m MIBI myocardial perfusion imaging in order to assist in the evaluation of the Inferior wall of the left ventricle. Methods: Initially a retrospective study was performed on 40 patients referred for myocardial perfusion scintigraphy. Two groups of patients were studied; in one group (group A) patients did not receive water and in the second group (group B) each patient drank 400ml of water directly before imaging. Based on the results of the retrospective study, a prospective study has been initiated. Each patient will be imaged twice after stress or during rest. During part 1 patients will abstain from water and food before imaging. In part 2, imaging will be repeated after the ingestion of 2 glasses (400mi) water and 2 slices of buttered bread. In each patient myocardial perfusion of the inferior wall will be compared with and without water and a light meal. Results: Results from the retrospective study comparing 2 groups of patients show that there is better visibility of Inferior wall perfusion of patients in group B, implying that more

  8. 99Tcm-MIBI single photon emission tomography (SPET) for detecting myocardial ischaemia and necrosis in patients with significant coronary artery disease

    International Nuclear Information System (INIS)

    Sciammarella, M.G.; Fragasso, G.; Gerundini, P.; Maffioli, L.; Cappelletti, A.; Margonato, A.; Savi, A.; Chierchia, S.

    1992-01-01

    The ability of 99 Tc m -methoxyisobutylisonitrile (MIBI) single photon emission tomography (SPET) to detect myocardial ischaemia and necrosis was assessed in 56 patients with clinically recognised ischaemic heart disease (IHD). All underwent coronary angiography (CA) and left ventriculography (LV). SPET images were obtained at rest and at peak exercise 90 min after injection of 99 Tc m -MIBI. The presence of persistent (P) or reversible (R) perfusion defects (PD) was then correlated to the resting and exercise ECG and to the results of CA and LV. Of the 56 patients, 34 had reversible underperfusion (RPD), 46 persistent underperfusion (PPD) and 31 had both. The occurrence of RPD correlated well with the occurrence of exercise-induced ST segment depression and/or angina (27 patients of 34 patients, 79%) and with the presence of significant coronary artery disease (CAD) (33 of 44, 73%). In 45 of 46 patients (98%) PPD corresponded to akinetic or severely hypokinetic segments (LV) usually explored by ECG leads exhibiting diagnostic Q waves (42 of 46 patients, 91%). The scan was normal both at rest and after stress in four of 11 patients with no CAD, and in two of 45 patients with CAD. Finally, an abnormal resting scan was seen in seven of 11 patients with normal coronary arteries, of whom six had regional wall motion abnormalities. In conclusion, MIBI SPET is a highly reliable technique for assessing the presence and location of myocardial ischaemia and necrosis. (Author)

  9. Balloon-based adjuvant radiotherapy in breast cancer: comparison between {sup 99m}Tc and HDR {sup 192}Ir

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Tarcisio Passos Ribeiro de; Lima, Carla Flavia de; Cuperschmid, Ethel Mizrahy, E-mail: tprcampos@pq.cnpq.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil)

    2016-03-15

    Objective: To perform a comparative dosimetric analysis, based on computer simulations, of temporary balloon implants with {sup 99m}Tc and balloon brachytherapy with high-dose-rate (HDR) {sup 192}Ir, as boosts to radiotherapy. We hypothesized that the two techniques would produce equivalent doses under pre-established conditions of activity and exposure time. Materials and methods: simulations of implants with {sup 99m}Tc-filled and HDR {sup 192}Ir-filled balloons were performed with the Siscodes/MCNP5, modeling in voxels a magnetic resonance imaging set related to a young female. Spatial dose rate distributions were determined. In the dosimetric analysis of the protocols, the exposure time and the level of activity required were specified. Results: the {sup 99m}Tc balloon presented a weighted dose rate in the tumor bed of 0.428 cGy.h{sup -1}.mCi{sup -1} and 0.190 cGyh{sup -1} at the balloon surface and at 8-10 mm from the surface, respectively, compared with 0.499 and 0.150 cGyh{sup -1}.mCi{sup -1}, respectively, for the HDR {sup 192}Ir balloon. An exposure time of 24 hours was required for the {sup 99m}Tc balloon to produce a boost of 10.14 Gy with 1.0 Ci, whereas only 24 minutes with 10.0 Ci segments were required for the HDR {sup 192}Ir balloon to produce a boost of 5.14 Gy at the same reference point, or 10.28 Gy in two 24-minutes fractions. Conclusion: temporary {sup 99m}Tc balloon implantation is an attractive option for adjuvant radiotherapy in breast cancer, because of its availability, economic viability, and similar dosimetry in comparison with the use of HDR {sup 192}Ir balloon implantation, which is the current standard in clinical practice. (author)

  10. Pharmacokinetic model of myocardial 99mTc-sestamibi washout

    International Nuclear Information System (INIS)

    Watanabe, Tsubasa; Monzen, Hajime; Mizowaki, Takashi; Hiraoka, Masahiro; Hara, Masatake

    2013-01-01

    Technetium-99m sestamibi ( 99m Tc-MIBI) scintigraphy has been reported to be a functional imaging tool for in vivo detection of mitochondrial dysfunction in myocardium and multidrug resistance-associated protein expression in tumors. The purpose of this study was to propose a clinically applicable pharmacokinetic model with metabolic equilibrium of 99m Tc-MIBI and to evaluate the accuracy of the model. For this study, eight healthy men received 99m Tc-MIBI scintigraphy. The planar images were obtained at 0.25, 0.5, 1, 2, 3, 4, 5, and 6 h after 99m Tc-MIBI injection. The measured time series 99m Tc-MIBI counts were fitted to our model by nonlinear regression analysis. The predictive performance of the model was determined by comparing the residuals between measured and predicted values. We obtained a good regression by fitting data from 0.25 to 6 h after 99m Tc-MIBI injection, with excellent correlation between measured and predicted 99m Tc-MIBI counts (R 2 =0.9792) and a slope near unity. The 95% confidence interval of the mean prediction error included 0, which means that the prediction was not significantly biased. The precision of the prediction was also excellent. Our model shows good predictive capacity, with favorable bias and accuracy. By comparing the predictive values of this model with measured values, mitochondrial 99m Tc-MIBI washout can be quantified. 99m Tc-MIBI washout rates are reported to be a promising method for evaluating cardiac function in patients with cardiac diseases and P-glycoprotein expression in tumor cells. Therefore, this quantification could be useful for mitochondrial functional imaging, especially in patients with cardiac diseases or tumors. (author)

  11. Thallium-201 is comparable to technetium-99m-sestamibi for estimating cardiac function in patients with abnormal myocardial perfusion imaging

    Directory of Open Access Journals (Sweden)

    Ming-Che Wu

    2015-11-01

    Full Text Available We analyzed the left-ventricular functional data obtained by cardiac-gated single-photon emission computed tomography myocardial perfusion imaging (MPI with thallium-201 (Tl-201 and technetium-99m-sestamibi (MIBI protocols in different groups of patients, and compared the data between Tl-201 and MIBI. Two hundred and seventy-two patients undergoing dipyridamole stress/redistribution Tl-201 MPI and 563 patients undergoing 1-day rest/dipyridamole stress MIBI MPI were included. Higher mean stress ejection fraction (EF, rest EF, and change in EF (ΔEF were noticed in the normal MPI groups by both Tl-201 and MIBI protocols. Higher mean EF was observed in the females with normal MPI results despite their higher mean age. Comparisons between the Tl-201 and MIBI groups suggested a significant difference in all functional parameters, except for the rest end diastolic volume/end systolic volume and ΔEF between groups with negative MPI results. For the positive MPI groups, there was no significant difference in all parameters, except for the change in end diastolic volume and change in end systolic volume after stress between both protocols. The Tl-201 provides comparable left-ventricular functional data to MIBI cardiac-gated single-photon emission computed tomography in patients with positive MPI results, and may therefore be undertaken routinely for incremental functional information that is especially valuable to this patient group.

  12. Preliminary applied study of assessment ischemic/viable myocardium by 99Tcm-HL91

    International Nuclear Information System (INIS)

    Liu Gang; Wu Hua

    2004-01-01

    Objective: To investigate the representation of 99 Tc m -HL91 in the ischemic myocardium, evaluate the diagnosis value of 99 Tc m -HL91 on hypoxic but viable myocardium. Methods: Six patients with cardiac infarction all underwent 99 Tc m -MIBI SPECT and 99 Tc m -HL91 SPECT. Average radioactivity of ischemic area and normal area were respectively obtained by ROI (2 x 2 pixels) on heart minor axis of images, And the radioactivity ratios of target (ischemic area)-to-non target(normal area)were calculated. Results: In image of 99 Tc m -HL91 SPECT, two patients who's radioactivity coloboma of 99 Tc m -MIBI image could be filled with 99 Tc m -HL91, four patients were not caught sight of obvious filling up. Conclusion 99 Tc m -HL91 can be selectively uptaken by ischemic and hypoxic but viable myocardium. it combination of 99 Tc m -MIBI SPECT may be good for accurate diagnosis and differentiation of viable myocardium. (authors)

  13. Analysis of the influence factors on myocardium to liver ratio of 99Tcm-MIBI

    International Nuclear Information System (INIS)

    Zhang Jinming; Tian Jiahe; Zhao Xiaoguang; Liu Zilai; Wang Shengcai

    1995-01-01

    The resting myocardial SPECT by different MIBI kits for 113 cases of normal and ischemic heart disease is performed. The preparation of kits, reducing agents, and the time of imaging are checked using myocardium to liver (M/L) ratio as the parameter of myocardium uptake of MIBI. It shows that MIBI uptake of myocardium has no relation with the reducing agents, the time of imaging between 60-120 min, while M/L ratio varied in every individual case. The ratio of M/L has also no relation to the Radiochemical Purity (RCP) as long as RCP is more than 95%

  14. Use of pyrophosphate-/sup 99m/Tc in diagnosis of malignant tumors of bones

    Energy Technology Data Exchange (ETDEWEB)

    Kasatkin, Yu N; Purizhanskii, I I; Survila, Z P; Agranat, V Z; Korsunskii, V N

    1976-10-01

    Pyrophosphate-/sup 99m/Tc was administered intravenously in a dose of 0.05 to 0.08 mCi per 1 kg body weight of the patient. Studies were made after 4, 6, and 24 hours with fixed and movable detectors. During investigations a gamma-chamber magnetic memory and a 4096-channel analyzer were also used. A quantitative processing of the material was made. The authors determined distribution of the preparation in normal and pathological bone tissue. A total of 142 patients with tumors of the bone tissue were examined; 858 radioisotope measurements were made. An analysis of accumulation of pyrophosphate-/sup 99m/Tc in primary osteogenic tumors in systemic affections of the bones and bone metastases was made. There is a relation between the concentration of the radiopharmaceutical preparation and the morphological structure of the tumor. Reduction in the accumulation of the radioactive indicator took place after radiation and medicinal effect, this made it possible to judge the regression of the tumor.

  15. Synthesis of the compound tetrakis (2- methoxy isobutyl isonitrile) copper (I) tetrafluoroborate -(Cu[MIBI]4BF4): substance used in the production of the radiopharmaceutical sestamibi 99m Tc

    International Nuclear Information System (INIS)

    Silva, Katia Suzi da Silveira

    2005-01-01

    The radiopharmaceutical SESTAMIBI- 99m Tc presents interest and application in the clinical routine in Nuclear Medicine, especially for evaluation of the myocardium function and in the diagnosis of some tumors types, and the Center of Radiopharmacy of the IPEN has interest in the development of this radiopharmaceutical for attendance of the nuclear medicine class necessities. In this work it was demonstrated the synthesis and characterization of the active compound tetrakis (2- methoxy isobutyl isonitrile) copper (I) tetrafluoroborate - Cu[MIBI] 4 BF 4 - to be used in the preparation of lyophilized reagents for labeling with technetium- 99m as well as labeling studies and biological distribution. The synthesis of the reagent Cu[MIBI] 4 BF 4 was carried out in accordance with previously described procedures, in 5 steps and the compounds were characterized for infra-red, magnetic nuclear resonance, melting point and thin layer chromatography. The characterization of the chelate of MIBI -Cu[MIBI] 4 BF 4 - was carried out using high performance liquid chromatography, compared with a standard sample of the product and presented similar results, as described in literature. The lyophilized reagent was prepared and labeled with technetium- 99m , showing high radiochemical purity, higher than 97%, with high stability. Biological distribution in different animals showed good uptake in the heart, in time compatible with the acquisition of scintigraphy images, demonstrating the applicability of the reagent synthesized in the attainment of cardiac scintigraphy images. (author)

  16. Production of the antimicrobial peptide UBI 29-41 labelled with 99mTc by an indirect method; Obtencion del peptido antimicrobiano UBI 29-41 marcado con 99mTc empleando un metodo indirecto

    Energy Technology Data Exchange (ETDEWEB)

    Nevares, Noemi; Crudo, Jose L; Zapata, Miguel; Castiglia, Silvia G. de [Comision Nacional de Energia Atomica, Ezeiza (Argentina). Dept. de Radioquimica

    2003-07-01

    The infection processes are a major problem in human health causing a high number of human deaths all around the world. Diagnostic imaging in nuclear medicine is an attractive option in the detection of infection processes due to its sensitivity. The antimicrobial peptides are very important in the development of new radiopharmaceuticals, since their antimicrobial activity towards a great variety of microorganisms have been proven. The aim of this work was to obtain the antimicrobial peptide UBI 29-41 labelled with technetium 99 m, by an indirect method via NHS-Hynic and tricine as a coligand, and evaluate its stability and its ability to discriminate between infection and inflammation sites. The radiochemical purity of the labeling procedure was 95.5{+-}1,2 %. The cysteine challenge showed a great stability of the 99mTc UBI-Hynic, and the stability in human serum showed that the 81% of the radioactivity remained bounded to UBI-Hynic at 48 hs of incubation. The bio distribution's studies showed main elimination via kidney of 99mTc UBI-Hynic and the target/non target ratio was 1,81 for infected mice and 1,16 for inflamed mice. (author)

  17. Comparative study of tricarbonilic complexes of {sup 99m}TC in the diagnosis of fungal infections

    Energy Technology Data Exchange (ETDEWEB)

    Fernández, Leticia Gabriela; Teran, Mariella Adriana [Facultad de Quimica, Montevideo (Uruguay); Reyes, Ana Laura [Cudim, Montevideo (Uruguay)

    2017-07-01

    Full text: Introduction: Clinical-epidemiological studies show that the incidence of fungal infections has experienced a substantial increase in the last years. Our working group focused on the radioactive labelling of commercially available antifungal agents and their evaluation as potential specific tracer agents for fungal infections (Curr Radiopharm, 2014, 7( 2), 144-150). Objective: Optimization of various antifungal agents labelling using {sup 99m}Tc tricarbonyl complexes and their subsequent evaluation in vitro and in vivo as radiotracers in the detection, through scintigraphic images, of fungal infections. Methodology: Complexes were obtained by substitution of the precursor triaquotricarboniltechnetium (I) with the antifungals: Caspofungin, amphotericin b, Voriconazole and Fluconazole[2]. The physicochemical evaluation of the complexes was performed by the analysis of the stability in milieu, stability in plasma, lipophilicity, plasma protein binding and binding to yeasts. The biological evaluation of the complexes was carried out according to the protocol 070510 approved by the Commission of Animal Experimentation (University of the Republic, Uruguay). The model used consisted of CD1 mice (n=4 per group), females of 8-10 weeks with a weight of 22 ± 2 g. The groups studied were: G0=healthy animals, G1=sterile inflammation, G2=infection by C.albicans and G3=infection by A.niger. The lesions were induced by inoculation of 100μL of the agents in the left hind thigh. Once the lesions were developed, the complexes were administered iv (37MBq,1mCi in 0.1mL) and biodistribution studies were performed at various post-injection times. In addition, images were acquired in a preclinical image system for animals for 60 min, 40 mm ROR, 5-pinhole collimator, 80 x 80 pixel array. Results: All the complexes were obtained with a radiochemical purity higher to 90,0% and were stable more than 4 hours post substitution. Plasma stability, Log P, Protein binding and C

  18. Direct elution of sup(99m)Tc complexes from neutron irradiation produced /sup 99/Mo incorporated in a MoCl/sub 2/-MoBr/sub 2/ mixture

    Energy Technology Data Exchange (ETDEWEB)

    Ganzerli Valentini, M.T.; Stella, R.; Genova, N.

    1987-01-01

    A novel type of sup(99m)Tc generator, enabling radiopharmaceutical preparation without reductant addition, was prepared and tested. Neutron activated product /sup 99/Mo, in the form of dichloride cluster, was incorporated into inactive molybdenum dichloride-dibromide mixture (MCB) that was left to settle over an activated alumina layer. Direct elution with aqueous ligands such as salicylate or iminodiacetate derivatives in the pH range 6.5-7.5 yielded chemically stable sup(99m)Tc complexes accompanied by small amounts of secondary products (mostly sup(99m)TcO/sup -//sub 4/). Pentavalent oxidation state in the salicylate complex and tervalent in the iminodiacetate (IDA) and in the N-(2,6-dimethylphenylcarbamoylmethyl) iminodiacetate (HIDA) complexes were assigned to the element after comparison with reference complexes. The anion exchange version of reverse-phase HPLC was used to resolve the eluted product mixture.

  19. Experience in infection images with new radio antibiotic the {sup 99m}Tc-ceftizoxime (TCF); Experiencia en imagenes de infecciones con un nuevo radio-antibiotico la ceftizoxima-{sup 99m}Tc (CFT)

    Energy Technology Data Exchange (ETDEWEB)

    Soroa, Victoria E; Rabiller, Graciela; Velasquez Espeche, Maria del H. [Comision Nacional de Energia Atomica, Buenos Aires (Argentina). Centro de Medicina Nuclear; Fioriolli, Marcelo H; Rodriguez, Hernan [Hospital de Clinicas Jose de San Martin, Buenos Aires (Argentina); Roca, Manuel; Martin-Comin, Joseph [Hospital Universitario Bellvitge, Barcelona (Spain). Servicio de Medicina Nuclear

    2004-07-01

    Previous results obtained in the detection of infections with {sup 99m}Tc-ceftizoxime encourage to the group of work to investigate the behavior of an antibiotic of third generation: the ceftizoxime radiolabelled with {sup 99m}Tc and to compare it with other radio-labels in different infectious / inflammatory pathologies. [Spanish] Anteriores resultados obtenidos en la deteccion de infecciones con el {sup 99m}TC-ceftizoxima incentivo al grupo de trabajo a investigar el comportamiento de un antibiotico de tercera generacion: la ceftizoxima radiomarcada con {sup 99m}Tc y compararlo con otros radiomarcadores en diferentes patologias infecciosas/inflamatorias.

  20. Assessment of sistemic ventricle function in corrected transposition of great arteries with Gated SPECT: comparison with radionuclide ventriculography

    International Nuclear Information System (INIS)

    Alexanderson, E.; Espinola, N.; Duenas, D.; Fermon, S.; Acevedo, C.; Martinez, C.

    2002-01-01

    Corrected trasposition of great arteries is a uncommon congenital heart disease where the right ventricle works as the sistemic one. QGS Gated SPECT program was designed to recognize the contours of left ventricle being a good method to evaluate left ventricle ejection fraction. The purpose of this study was to evaluate the right ventricle ejection fraction (RVEF) by gated SPECT using Tc-99mSestaMIBI in comparison with radionuclide ventriculography (RVG) in patients with corrected trasposition of great arteries. Methods: We performed gated SPECT and radionuclide ventriculography within 15 days of each other in 7 adults consecutive patients with the diagnosis of corrected trasposition of great arteries (5 men, 2 women; mean age 47 y). Gated tomographic data, including ventricular volumes and ejection fraction, were processed using QGS automatic algorithm, whereas equilibrium radionuclide ventriculography used standard techniques. Results: We found a good correlation between right ventricle ejection fraction obtained with Gated SPECT compared with equilibrium radionuclide ventriculography. The mean of the RVEF with Gated SPECT was 41.2% compared with 44.2% of RVEF with equilibrium radionuclide ventriculography. Both methods recognized abnormal RVEF in 5 patients ( 50%) with Gated SPECT and abnormal with RVG meanwhile another patient had normal RVEF with RVG and abnormal with Gated SPECT. Conclusion: Quantitative gated tomography, using Tc 99mSestaMIBI, has a good correlation with radionuclide ventriculography for the assessment of right ventricle ejection fraction in patients with corrected trasposition of great arteries. These results support the clinical use of this technique among these patients

  1. Comparison of film sensitivity for sup(99m)Tc gamma-rays

    International Nuclear Information System (INIS)

    Kojima, Kazuhiko; Katayama, Masaharu; Hisada, Kinichi.

    1975-01-01

    Recently a new method of γ-ray imaging by holography has been studied at several nuclear medical laboratories. The holography is of a very simple. An axis Fresnel zone plate made of lead (2 mm thickness) is placed between the γ-ray source and a detector, and its shadow is recorded as a hologram. The hologram obtained is illuminated by parallel beams of He-Ne laser (6328 A), and an image of the radioisotope distribution in the object is reconstructed by diffraction. The better the resolution of the shadow hologram, the better are the reconstructed images obtained. For this reason the detector for recording the γ-ray hologram must be selected carefully. Three kinds of medical X-ray film were used as detectors for holograms to compare film sensitivity. Generally these medical X-ray films have poor sensitivity to γ-rays of sup(99m)Tc. In order to intensify the film sensitivity for γ-rays of sup(99m)Tc, combinations of six kinds of intensifying screens were studied. Good film sensitivity was obtained by RP (Kodak Co.) film combined with a KZ-S fluorescent intensifying screen. The fluorescent screen was better than fluorometallic screens with similar properties. Using this film-screen combination, shadow holograms could be recorded for 2-3 minutes and images could be optically reconstructed. (auth.)

  2. {sup 99m}Tc radiolabeling and biodistribution study of scorpionfish (Scorpaena plumieri) venom in Swiss mice

    Energy Technology Data Exchange (ETDEWEB)

    Soprani, Juliana; Pujatti, Priscilla B.; Santos, Raquel G. dos [Centro de Desenvolvimento da Tecnologia Nuclear(CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Lab. de Radiobiologia]. E-mail: falejs@yahoo.com.br; priscillapujatti@yahoo.com.br; santosr@cdtn.br; Figueiredo, Suely G. de [Universidade Federal do Espirito Santo (UFES), Vitoria, ES (Brazil). Depto. de Ciencias Fisiologicas]. E-mail: suelygf@gmail.com; Simal, Carlos [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Faculdade de Medicina]. E-mail: csimal@brfree.com.br

    2007-07-01

    The use of radiotracers in research of animal venom has been scarce, although it allows an excellent approach to follow the process of biodistribution and kinetics of toxins, and tissue distribution studies are very important for clinical use. Our group has demonstrated that Scorpaena plumieri venom (SP) possess high antitumoral activity and can be a source of template molecules for the development of antitumoral drugs. The purpose of this study was to radiolabel SP with 99mTc and investigate its biodistribution profile. High labeling yield was obtained and the results suggest that [99mTc]SP can be an useful tool for in vivo studies. The analysis indicated that SP is excreted manly by the kidneys with a slow clearance rate. The significant [99mTc]SP uptake in the heart and lungs may explain, at least partially, the pulmonary edema and effect cardiac observed by the envenoming. (author)

  3. Adenosine stress and exercise 99Tcm-MIBI myocardial perfusion imaging in the diagnosis and risk stratification of patients with unstable angina

    International Nuclear Information System (INIS)

    Jia Peng; Guo Wanhua; Xu Shoulin; Feng Xuefeng

    2008-01-01

    Objective: The aim of this study was to evaluate the clinical value of adenosine stress or exercise 99 Tc m -methoxyisobutylisonitrile (MIBI) myocardial perfusion imaging in the diagnosis and risk stratification of patients with unstable angina. Methods: Eighty-seven hospitalized patients with unstable angina [54 men and 33 women, aged of (56.5±12.5) years] underwent adenosine stress or exercise myocardial perfusion imaging and coronary angiography. Patients were followed up. Results: Fifty-seven patients had abnormal myocardial perfusion imaging and significant coronary artery stenosis. Ten patients had abnormal myocardial perfusion imaging but normal coronary angiography. Eight patients had normal myocardial perfusion imaging but significant coronary artery stenosis. Twelve patients had normal myocardial perfusion imaging and normal coronary angiography. Patients with abnormal myocardial perfusion imaging had worse prognosis. There was relationship between cardiac events and the extent and severity of myocardial ischemia. Conclusion: Adenosine stress and exercise myocardial perfusion imaging is of important clinical value in the diagnosis and risk stratification of patients with unstable angina. (authors)

  4. Identification of Hürthle cell tumor by single-injection, double-phase scintigraphy with technetium-99m-sestamibi.

    Science.gov (United States)

    Vattimo, A; Bertelli, P; Cintorino, M; Burroni, L; Volterrani, D; Vella, A

    1995-05-01

    Early and late (double-phase) scintigraphy with 99mTc-MIBI was used in a comparative study of the scintigraphic aspects of Hürthle cell tumors and other thyroid tumors. Single-injection, dual-phase (15-30 min and 3-4 hr) thyroid scintigraphy with 99mTc-sestamibi (MIBI) was performed on 41 patients who displayed a cold nodule on previous 99mTc scintigraphy. Visual scoring of nodular uptake was done to compare thyroidal and background tracer uptake. In addition, the nodular-to-thyroid (N/T) uptake ratio in the early and late images and the washout rate from the nodule (WON) and thyroidal tissue (WOT) were measured. Cytologic results were obtained for all patients; histopathologic results were obtained for the 20 patients who had surgery. In eight patients (Group A), the nodule displayed intense and persistent uptake of MIBI (N/T = 1.77 +/- 0.46 and 3.20 +/- 1.37; WON = 17.2% +/- 6.3%; WOT = 24.6% +/- 7.5%); histopathology revealed Hürthle cell tumors (two carcinomas and three adenomas) in five surgical patients. In 15 patients (Group B), the nodule displayed intense uptake in the early image with fading activity in the late image (N/T = 1.45 +/- 0.54 and 0.84 +/- 0.30; WON = 30.0% +/- 7.3%; WOT = 24.5% +/- 6.8%); histopathology revealed a colloid nodule (n = 1), papillary carcinoma (n = 4) and follicular carcinoma (n = 5) in 10 surgical patients. In the remaining 18 patients (Group C), the nodule was cold and late images were not acquired. Histopathology revealed colloid nodules (n = 2) and follicular adenoma (n = 3) in five surgical patients. Single-injection, dual-phase MIBI scintigraphy of the thyroid can identify Hürthle cell tumors because these tumors have intense, persistent tracer uptake in contrast to other thyroid tumors.

  5. Studies of labelling conditions for gentamicin with sup(99m)Tc. Complexation with ruthexium. Establishment of pharmacokinetics parameters through compartmental analysis

    International Nuclear Information System (INIS)

    Carvalho, O.G. de.

    1988-01-01

    Gentamicin sulphate is an aminoglycoside antibiotic type specifically used for treatment of infections produced by Gram-negative bacterias but at the other hand it presents ototoxic reactions as a serious side effect. The main purpose of labelling gentamicin with sup(99m)Tc was to obtain a radioactive tracer to carry out biological studies and compartmental analysis of this antibiotic. The optimal labelling conditions of gentamicin sulphate with sup(99m)Tc, using sodium pertechnetate solution eluted from a sup(99)Mo- sup(99m)Tc generator, were stablished by testing different masses of antibiotic, and reduction agent (SnCl sub(2).2H sub(2)O), and also different reaction time and final labelling PH. The same labelling procedure was used with Re (amonium perrenate) in order to obtain some semi-quantitative approximations of the chemical structure of the complex formed, since Re and Tc present similar chemical characteristics. In this way it is possible to suggest the role that the groups NH2 and C-O bonding of the gentamicin play in the complexation process. From the studies of the biological uptake of sup(99m)Tc-gentamicin sulphate in rats, the kidneys showed the highest affinity for the antibiotic. The maximum uptake was observed in 180 to 240 minutes followed by a decrease of it afterwards. For the dose and time used, no significative uptake by the auricular region was detected. Curve of plasma decay of sup(99m)Tc-gentamicin was obtained, and from the exponentials of each beanch of this curve respective half-lives were calculated. Furthermore the apparent volume of distribution was determined, and with the residual radioactivity in the body, the biological half-life and total clearance were obtained. The distribution of sup(99m)Tc-gentamicin in rats was set in a bi-compartments in addition to a retention one for the 24 hours time interval studied. (author)

  6. Evaluation of 99mTc labelled human immunoglobulin (99mTc-HIG) in infection/inflammatory foci imaging. Final report for the period 15 December 1996 - 15 August 1997

    International Nuclear Information System (INIS)

    Shimpi, H.H.

    1997-10-01

    The aim of the study was to investigate whether the labelling efficiency biodistribution and inflammatory focus detection are dependent on the source of the human immunoglobulin G (HIG) and the chelating agent used in the labelling of the HIG with 99mTc. Three forms of immunoglobulins; Gamma venin P, Intraglobulin F and Sandoglobulin were used in this study. Reduction of HIG was done by 2-mercaptoethanol at molar ratio 1000:1, with 30 minutes reaction time at room temperature. The reduced HIG was then purified, membrane filtered aliquoted and lyophilised. Lyophilised HIG was dissolved in sterile normal saline and chelated with one of the following ligands Sn-MDP, SN PYP, Sn DTPA, SN-GH and Sn-citrate and then added 99m Tc04 for labelling. The radiochemical purity of the labelled compound was 90%. The biodistribution studies were done wistar rats where in the experimental groups were sacrifised at 3,5 and 24 hours following 99mTc HIG injection intravenously. Imaging studies were carried out in rabbits. Sterile inflammatory lesions were produced in the thigh muscle of these animals by injection of turpentine oil and the contralateral thigh muscle served as-controls. The results showed that there was no significant difference in biodistribution and inflammatory focus uptake of 9gmTc HIG with respect to the sources of HIG. There was favourable biodistribution characteristics when the ligands used were Sn MDP and Sn-Citrate

  7. Radioactive excretion in human milk following administration of /sup 99m/Tc macroaggregated albumin

    International Nuclear Information System (INIS)

    Pittard, W.B.; Merkatz, R.; Fletcher, B.D.

    1982-01-01

    Albumin-tagged sodium pertechnetate (technetium) is routinely used in nuclear medicine for scanning procedures of the lung. The rate of excretion of this radionuclide into breast milk and the resultant potential radiation hazard to the nursing infant have received little attention. Therefore the milk from a nursing mother who required a lung scan because of suspected pulmonary emboli using an intravenous injection of 4 mCi of /sup 99m/Tc macroaggregated human serum albumin was monitored. Albumin tagging severely limited the entrance of technetium into her milk and the radioactivity of the milk returned to base line by 24 hours. A total of 2.02 muCi of technetium was measured in the 24-hour milk collection after technetium injection and 94% of this amount was excreted by 15.5 hours. This amount of technetium administered orally to a newborn would deliver a total body radiation dose of .3 mrad. Therefore, an infant would receive trivial doses of radiation if breast-feeding were resumed 15.5 hours after administration of the radionuclide to the mother and nursing can clearly be resumed safely 24 hours after injection

  8. Osteosclerotic and osteolytic manifestations of hyperparathyroidism in a case of Tc99m SestaMIBI positive parathyroid adenoma

    International Nuclear Information System (INIS)

    Das, Kalpa Jyoti; Sehgal, Aditi Khurana; Jaiman, Ashish; Sethi, Ravinder Singh

    2005-01-01

    Primary hyperparathyroidism is the first differential diagnosis when a patient presents with asymptomatic hypercalcemia. The symptoms of hyperparathyroidism can be as grave as skeletal, cardiovascular, and neuropsychological changes. Skeletal manifestations are relatively common, and patient may present with generalized or focal bone pains, fragility fractures, subperiosteal bone resorption, and osteolytic lesions like brown tumors and salt and pepper appearance of the skull. However, focal osteosclerotic lesions of the skull are rare findings in hyperparathyroidism. Only a few cases of associated osteosclerosis are reported in the literature. Here, we report a case of Tc99m SestaMIBI positive parathyroid adenoma with coexisting osteolytic and osteosclerotic skull lesions on Tc99m methylene diphosphonate bone scan

  9. Radiation-hygienic assessment of sup(99m)Tc generators

    International Nuclear Information System (INIS)

    Panfilova, N.P.; Kochetova, G.P.; Zol'nikova, N.I.; Trunov, B.V.

    1985-01-01

    Radiation-hygienic evaluation of labour conditions and degree of medical personnel irradiation during operation of short-lived radionuclide generators (of the activity 12950MBq, 18500 MBq) in radionuclide diagnosis has been made. For the purpose the exposure dose rate in working places from sup(99m)Tc generator was determined. Simultaneously, operation by operation timing at all the sta.oes of technological process is carried out. Measurements are realized at four levels (head, breast, pelvis, hands). It is shown, that total personnel dose at the first day of operation with generator constitutes 8.64 mR to hands, 1.12 mR to head, 2.333 mR to breast, 1.309 mR to pelvis

  10. The study of interaction of modified fatty acid with {sup 99m}Tc in alcoholic media

    Energy Technology Data Exchange (ETDEWEB)

    Skuridin, V. S.; Stasyuk, E. S.; Varlamova, N. V.; Nesterov, E. A.; Sadkin, V. L.; Rogov, A. S., E-mail: rogov@tpu.ru; Ilina, E. A.; Larionova, L. A.; Villa, N. E. [Institute of Physics and Technology, Tomsk Polytechnic University, Tomsk, 634050 (Russian Federation); Sinilkin, I. G.; Zelchan, R. V. [Institute of Physics and Technology, Tomsk Polytechnic University, Tomsk, 634050 (Russian Federation); Tomsk Cancer Research Institute, Tomsk, 634050 (Russian Federation); Sazonova, S. I. [Institute of Physics and Technology, Tomsk Polytechnic University, Tomsk, 634050 (Russian Federation); Research Institute of Cardiology, Tomsk, 634012 (Russian Federation)

    2016-08-02

    The paper presents the results of laboratory research aimed at the development of methods of synthesis of new radiodiagnostic agents based on modified fatty acid labelled with technetium-99m intended for scintigraphic evaluation of myocardial metabolism. In particular, the interaction of substance with {sup 99m}Tc in alcoholic media and the use of ethanol as solvent in the synthesis of the radiopharmaceutical were studied.

  11. Radionuclide study of thyroid function in pediatrics, using sup(99m)Tc, 123I or 131I: 150 case-reports

    International Nuclear Information System (INIS)

    Guillet, J.; Basse-Cathalinat, B.; Soubiran, G.; Blanquet, P.; Guillet, G.

    1981-01-01

    THe best radioisotope for in vivo thyroid investigations is the one which provides the highest quality scintigrams with the least radiation exposure. The choice of 131 I, 123 I or sup(99m)Tc in 150 children is discussed. Cases included 25 dysgenesis, 4 goiters with hypothyroidism, 56 goiters without thyroid dysfunction, 3 thyroiditis, and 11 cold nodules. When thyroid scanning is performed with 131 I, the gland's radiation exposure is high. 123 I is preferable since a fairly high activity can be obtained without delivering an excessive radiation dose. (approximately 2 rad to the thyroid for 50 microCi/m 2 ). sup(99m)Tc which is readily available is not a true iodine analog. It does not give a true picture of iodine metabolism. 123 I was generally used in cases of hypothyroidism, goiter (whenever a defect in thyroid hormone synthesis was suspected) and hyperthyroidism. sup(99m)Tc was generally used in other cases. The low radiation doses delivered by these radioisotopes allows study of thyroid function in the neonate [fr

  12. Effective visualization of suppressed thyroid tissue by means of baseline 99mTc-methoxy isobutyl isonitrile in comparison with 99mTc-pertechnetate scintigraphy after TSH stimulation.

    Science.gov (United States)

    Vattimo, A; Bertelli, P; Burroni, L

    1992-01-01

    Baseline 99mTc-MIBI thyroid scintigraphy was compared with 99mTc-pertechnetate scintigraphy after TSH stimulation in seven patients with suppressed thyroid tissue due to an autonomously functioning thyroid nodule (AFTN). In all patients the suppressed thyroid tissue was visualized by means of both baseline 99mTc-MIBI and post-TSH 99mTc-pertechnetate scintigraphy, and in some cases the former technique provided better visualization. In one patient presenting a "warm" nodule T3-suppression did not affect the nodular/extranodular uptake ratio of 99mTc-MIBI, whereas the 99mTc-pertechnetate uptake ratio increased significantly. This leads us to hypothesize that the thyroid uptake of 99mTc-MIBI is not related to TSH control, but rather to other mechanisms such as the blood flow. Since exogenous TSH is no longer available, 99mTc-MIBI scintigraphy can be successfully used in the place of repeated 99mTc-pertechnetate scintigraphy after TSH stimulation in the assessment of AFTN.

  13. Rapid and accurate determination of radiochemical purity of sup(99m)Tc compounds

    International Nuclear Information System (INIS)

    Tamat, S.R.

    1977-01-01

    The wide spread use of sup(99m)Tc-labelled radiopharmaceuticals and limitation of the short half-life of the isotope, is associated with an urgent need for a rapid, simple but accurate method for determining the radiochemical purity of the compound. A short paper chromatographic (KK) or thin layer chromatographic (KLT) method using 95% methanol or 0.9% saline solution as solvents, has solved the problem. With these methods, the amount of free sup(99m)Tc pertechnetate in a compound, can be determined in only a few minutes. These methods compare satisfactorily with lengtheir procedures. (author)

  14. Accuracy of 99Molybdenum assays in /sup 99m/Technetium solutions

    International Nuclear Information System (INIS)

    Williams, C.C.; Kereiakes, J.G.; Grossman, L.W.

    1981-01-01

    A study was performed to determine the accuracy of 99 Mo measurements using three commercial dose calibrators with their 99 Mo assay shields. One 99 Mo assay shield allowed excessive penetration by the lower energy /sup 99m/Tc photons, resulting in the calibrator's falsely high interpretation of the activity of 99 Mo present in the high-activity /sup 99m/Tc eluates. All three calibrators performed adequately with a National Bureau of Standards 99 Mo standard in equilibrium with /sup 99m/Tc. By using low-activity aliquots of 99 Mo and /sup 99m/Tc, a low-level linearity test was performed. Only one of the calibrators was found to reflect accurately the activity of 99 Mo present under all conditions tested

  15. Comparison study among methodologies of planar chromatography for radiochemical control of technetium-99m

    International Nuclear Information System (INIS)

    Monteiro, Elisiane de Godoy

    2012-01-01

    Radiopharmaceuticals are substances that have radioisotopes in their composition. About 95% of the procedures performed in nuclear medicine use radiopharmaceuticals with diagnostic purposes, and the Lyophilized Reagents (LR) labeled with Technetium-99m ( 99 mTc), obtained from 99 Mo/ 99 mTc generator, are the most one used. Quality Control represents the set of assays to be performed to assure that the product is adequate to its purpose. An important feature to be evaluated in 99m Tc radiopharmaceuticals is the radiochemical purity (% RqP) to quantify free pertechnetate ( 99 mTcO 4 - ) and technetium colloidal (99mTcO 2 ) mainly by paper chromatography (PC), thin layer (TLC) and High Performance Liquid Chromatography (HPLC). The objective of this work was to perform the comparison among the radiochemical control methodologies of LR labeled with 99m Tc, described in the United States Pharmacopoeia (USP) and European Pharmacopoeia (EP) and those used by IPEN. 99m TcO 4 - eluate and DISIDA, DMSA, DTPA, EC, ECD, GHA, MIBI, MDP, PIRO, SAH and Sn Coloidal LR were provided by IPEN-CNEN/SP. TLC-cellulose, TLC-SG.TLC-SG reverse phase, HPTLC-cellulose, HPTLC-SG (Merck) and ITLC-SG (Pall Corporation), W1MM, W3MM, W17M e W31ET (Whatman) chromatographic plates were used. The measurement of the radioactivity was done in a Perkin Elmer Cobra D-5002 gamma counter. LR were labeled to obtain 55,0 MBq mL 1 (1,5 mCi mL 1 ) of final radioactive concentration. The % 99m TcO 4 - , % 99m TcO 2 and % RqP were determined up to 4 hour labeling. From 11 LR, only EC and GHA have no radiochemical control methods in USP and EP. In USP and/or EP, DTPA, MDP, PIRO, SAH and Sn Coloidal methods use ITLC-SG; IPEN uses this chromatography plate in DISIDA, EC, ECD, GHA, PIRO, MIBI and SAH. As ITLC-SG had been out of production (recommended in 40, 70 and 41% of the USP, EP and IPEN methodologies, respectively), it was necessary to search alternatives to replace ITLC-SG plate in the radiochemical control

  16. 99mTc-3PRGD2 Scintimammography in Palpable and Nonpalpable Breast Lesions

    Directory of Open Access Journals (Sweden)

    Lin Liu

    2014-07-01

    Full Text Available The aim of this study was to explore the diagnostic performance of 99mTc-3(poly-(ethylene glycol,PEG4-RGD2 (99mTc-3PRGD2 scintimammography (SMM in patients with either palpable or nonpalpable breast lesions and compare SMM to mammography to assess the possible incremental value of SMM in breast cancer detection. We also investigated the αvβ3 expression in malignant and benign breast lesions. Ninety-four patients with 110 lesions were included in this study. Mammograms were evaluated according to the Breast Imaging Reporting and Data System (BI-RADS by a specialized imaging radiologist. Prone SMM was performed 1 hour after injection of 99mTc-3PRGD2. Scintigraphic images were interpreted independently by two experienced nuclear medicine physicians using a three-point system, and the kappa value was calculated to determine the interreader agreement. The McNemar test was used to compare SMM and mammography with respect to sensitivity, specificity, and accuracy. Diagnostic values for breast cancer detection were evaluated for each lesion. Immunohistochemistry was performed to evaluate integrin αvβ3 expression. Histopathology revealed 46 malignant lesions and 64 benign lesions. The overall sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of SMM were 83%, 73%, 77%, 69%, and 85%, respectively. The kappa value between the two reviewers was 0.63. The diagnostic values of SMM were higher than those of mammography in evaluating overall breast lesions. A sensitivity of 91% was achieved when SMM and mammography results were combined with 60% of all false-negative mammography findings classified as true-positive results by SMM. Integrin αvβ3 expression was positively identified using SMM imaging. SMM is a promising tool to avoid unnecessary biopsies when used in addition to mammography and can be used to image αvβ3 expression in breast cancer with good image quality.

  17. Primary application of 99Tcm-octreotide imaging in the diagnosis of breast cancer

    International Nuclear Information System (INIS)

    Zhang Jinshan; Deng Nianying; Li Shun; Zhang Jiayun; Lin Yanbing

    2004-01-01

    Objective: To evaluate the clinical value of 99 Tc m -octreotide scintigraphy in the diagnosis of breast cancer. Methods: 99 Tc m -octreotide and 99 Tc m -methoxyisobutylisonitrile (MIBI) imaging were performed on 36 patients with breast masses confirmed by pathology (19 patients with breast cancer and 17 benign lesions) . The imaging was read as positive when focal radioactivity increased in the breast both on 99 Tc m -octreotide and 99 Tc m -MIBI imaging. The uptake ratios (UR) of lesion (L) to normal (N) were calculated after 99 Tc m -MIBI injection at 10-15 min and 99 Tc m -octreotide injection at different time points (5-10 min, 60-90 min and 180 min). Results: The sensitivity of 99 Tc m -octreotide imaging in the diagnosis of primary breast cancer was lower than that of 99 Tc m -MIBI (68.4% vs 94.7%, P 99 Tc m -octreotide and 99 Tc m -MIBI (83.3% and 86.1%, respectively, P>0.05). Conclusion: Comparing with 99 Tc m -MIBI 99 Tc m -octreotide imaging showed a higher specificity and the same accuracy in the diagnosis of breast cancer

  18. Evaluation of the influence of percent labeling of {sup 99m}Tc-MIBI on nuclear medicine procedures in Recife, Pernambuco State, Brazil; Avaliacao da influencia do percentual de marcacao do {sup 99m}Tc-MIBI em procedimentos de medicina nuclear em Recife, PE

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Jucilene Maria

    2003-08-15

    The aim of this work was to evaluate the influence of percent labeling of the radiopharmaceutical {sup 99m}Tc-MIBI on the procedures adopted by the nuclear medicine clinics in Recife, Pernambuco State, Brazil, and their possible interference with image quality in myocardial perfusion examinations. This work was performed at two nuclear medicine services in Recife that use pharmaceuticals provided by two different manufacturers: Cardiolite, provided by Dupont and Cardiosyd, provided by SYDMA. The pH, percent labeling and stability of samples of {sup 99m}Tc-MIBI and the percent uptake in heart and liver of a number of patients were evaluated. The results showed that the pH values measured in all samples of both radiopharmaceuticals were within the limits recommended. In 48% of the Cardiolite samples, the percent labeling was less than 90%, which is the minimum recommended limit. On the other hand, 87,5% of the Cardiosyd samples measured values above 98%. Both radiopharmaceuticals had good labeling stability, even in samples with low percent labeling efficiencies. In spite of the higher percent labeling of Cardiosyd its heart uptake is similar to that observed with the Cardiolite, even when the percent labeling is lower than 90%. On the other hand, the image quality, according to physicians, evaluation was poorer for Cardiosyd images, due to high noise and poor sharpness. (author)

  19. WE-AB-204-12: Dosimetry at the Sub-Cellular Scale of Auger-Electron Emitter 99m-Tc in a Mouse Single Thyroid Follicle Model

    Energy Technology Data Exchange (ETDEWEB)

    Taborda, A; Benabdallah, N; Desbree, A [Institut de Radioprotection et de Surete Nucleaire, Fontenay-aux-roses (France)

    2015-06-15

    Purpose: To perform a dosimetry study at the sub-cellular scale of Auger-electron emitter 99m-Tc using a mouse single thyroid cellular model to investigate the contribution of the 99m-Tc Auger-electrons to the absorbed dose and possible link to the thyroid stunning in in vivo experiments in mice, recently reported in literature. Methods: The simulation of S-values for Auger-electron emitting radionuclides was performed using both the recent MCNP6 software and the Geant4-DNA extension of the Geant4 toolkit. The dosimetric calculations were validated through comparison with results from literature, using a simple model of a single cell consisting of two concentric spheres of unit density water and for six Auger-electron emitting radionuclides. Furthermore, the S-values were calculated using a single thyroid follicle model for uniformly distributed 123-I and 125-I radionuclides and compared with published S-values. After validation, the simulation of the S-values was performed for the 99m-Tc radionuclide within the several mouse thyroid follicle cellular compartments, considering the radiative and non-radiative transitions of the 99m-Tc radiation spectrum. Results: The calculated S-values using MCNP6 are in good agreement with the results from literature, validating its use for the 99m-Tc S-values calculations. The most significant absorbed dose corresponds to the case where the radionuclide is uniformly distributed in the follicular cell’s nucleus, with a S-value of 7.8 mGy/disintegration, due mainly to the absorbed Auger-electrons. The results show that, at a sub-cellular scale, the emitted X-rays and gamma particles do not contribute significantly to the absorbed dose. Conclusion: In this work, MCNP6 was validated for dosimetric studies at the sub-cellular scale. It was shown that the contribution of the Auger-electrons to the absorbed dose is important at this scale compared to the emitted photons’ contribution and can’t be neglected. The obtained S

  20. Biochemical markers in the follow-up of medullary thyroid cancer

    NARCIS (Netherlands)

    de Groot, Jan Willem B.; Kema, Ido P.; Breukelman, Henk; van der Veer, Eveline; Wiggers, Theo; Plukker, John T. M.; Wolffenbuttel, Bruce H. R.; Links, Thera P.

    2006-01-01

    Medullary thyroid cancer (MTC) shares biochemical features with other neuroendocrine tumors but the particular characteristics are largely unexplored. We investigated the biochemical neuroendocrine profile of MTC and whether specific markers could be useful in follow-up. In addition to the standard

  1. Effects of Momordica charantia on osmotic fragility and label red blood cells and plasmatic protein with 99m-Tc in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Magnata, Simey S.L.P. [Pernambuco Univ., Recife, PE (Brazil). Dept. de Energia Nuclear]. E-mail: sfmagnata@terra.com.br; Correia, Marilia B.L.; Brandao, Jose Odinilson C.; Souza, Grace M.L.; Catanho, Maria Teresa J.A. [Pernambuco Univ., Recife, PE (Brazil). Dept. de Biofisica e Radiobiologia; Terra, Daniele A.; Amorim, Lucia F. [Rio Grande do Norte Univ., Natal, RN (Brazil). Dept. de Fisiologia

    2005-07-01

    The use of natural products in the treatment physiopathology awaken the interest in the inquiry of the action mechanisms. The Momordica charantia, Melao de Sao Caetano, is used in the Caribbean and Orient for the diseases as stomatitis, cancer and diabetes. This work aims to verify the effect of the Momordica charantia's aqueous extract leaves on osmotic fragility and on labeling red blood cells (RBC) and plasmatic proteins with {sup 99m}Tc in vitro. To evaluate the osmotic fragility, samples of heparinized blood (500 mL) was incubed for 1 hour with brut extract (500 mL) in different concentrations (0; 10; 50 and 100% v/v); after centrifugation, the RCB were submitted the incubation (1 hour) with a gradient of NaCl (0;0,1;0,25;0,4;0,7 and 0.9%), the OD of supernatant was determined. With regards to label red blood cells and plasmatic proteins with {sup 99m}Tc in vitro was carried out by incubating of anticoagulant whole blood (500 mL) for 1 hour with brut extract (500 mL) in different concentrations (0; 10; 50 and 100% v/v). A stannous chloride solution of 1,2 {mu}g/mL was added the incubation for 60 minutes. After this the {sup 99m}Tc (3,7 MBq) was added and the incubation was continued for another 10 minutes. Those were centrifuged, precipitated with trichloroacetic acid 5% and mensured in a counter. The results shows that with regard to osmotic fragility, only the extract in the concentration of 100% provoked hemolysis. The Momordica charantia's extract is an agent who modify the fixation of {sup 99m}Tc in red blood cells. The results show with regard to osmotic fragility, only the extract in the quantity 100% provoked hemolysis. It is concluded that the Momordica charantia's extract is an agent who unchains the cellular fragility and {sup 99m}Tc fixation, showing a reduction effect. (author)

  2. Scatter and cross-talk correction for one-day acquisition of 123I-BMIPP and 99mtc-tetrofosmin myocardial SPECT.

    Science.gov (United States)

    Kaneta, Tomohiro; Kurihara, Hideyuki; Hakamatsuka, Takashi; Ito, Hiroshi; Maruoka, Shin; Fukuda, Hiroshi; Takahashi, Shoki; Yamada, Shogo

    2004-12-01

    123I-15-(p-iodophenyl)-3-(R,S)-methylpentadecanoic acid (BMIPP) and 99mTc-tetrofosmin (TET) are widely used for evaluation of myocardial fatty acid metabolism and perfusion, respectively. ECG-gated TET SPECT is also used for evaluation of myocardial wall motion. These tests are often performed on the same day to minimize both the time required and inconvenience to patients and medical staff. However, as 123I and 99mTc have similar emission energies (159 keV and 140 keV, respectively), it is necessary to consider not only scattered photons, but also primary photons of each radionuclide detected in the wrong window (cross-talk). In this study, we developed and evaluated the effectiveness of a new scatter and cross-talk correction imaging protocol. Fourteen patients with ischemic heart disease or heart failure (8 men and 6 women with a mean age of 69.4 yr, ranging from 45 to 94 yr) were enrolled in this study. In the routine one-day acquisition protocol, BMIPP SPECT was performed in the morning, with TET SPECT performed 4 h later. An additional SPECT was performed just before injection of TET with the energy window for 99mTc. These data correspond to the scatter and cross-talk factor of the next TET SPECT. The correction was performed by subtraction of the scatter and cross-talk factor from TET SPECT. Data are presented as means +/- S.E. Statistical analyses were performed using Wilcoxon's matched-pairs signed-ranks test, and p corrected total count was 26.0 +/- 5.3%. EDV and ESV after correction were significantly greater than those before correction (p = 0.019 and 0.016, respectively). After correction, EF was smaller than that before correction, but the difference was not significant. Perfusion scores (17 segments per heart) were significantly lower after as compared with those before correction (p correction revealed significant differences in EDV, ESV, and perfusion scores. These observations indicate that scatter and cross-talk correction is required for one

  3. {sup 99m}Tc sestamibi cardiac tomography and dobutamine echocardiography in the identification of reversible left ventricular dysfunction in patients with acute myocardial infarction; Tomografia cardiaca con {sup 99m}Tc sestamibi ed ecocardiografia con dobutamina nell'identificazione della disfunzione ventricolare sinistra reversibile nei pazienti con infarto acuto del miocardio

    Energy Technology Data Exchange (ETDEWEB)

    Gisonni, P.; Cuocolo, A.; Spinelli, L.; Acampa, W.; Florimonte, L.; Nicolai, E.; Petretta, M.; Sodano, A. [Naples Univ. Federico 2. (Italy). Centro per la Medicina Nucleare del Consiglio Nazionale delle Ricerche. Dipt. di Scienze Biomorfologiche e Funzionali

    1999-04-01

    The authors investigated the role of technetium-99m ({sup 99m}Tc) sestamibi cardiac imaging and dobutamine echocardiography in detecting myocardial viability early after acute myocardial infarction. [Italian] La presenza di tessuto miocardico ibernato o stordito contribuisce alla genesi della disfunzione ventricolare sinistra nei pazienti con infarto del miocardio. L'identificazione del miocardio malfunzionante ma ancora vitale ha particolare rilevanza nel predire il recupero della funzione ventricolare in seguito a interventi di rivascolarizzazione coronarica. In questo studio e' stato valutato il ruolo della scintigrafia con tecnezio-99m ({sup 99m}Tc) sestamibi e dell'ecocardiografia con dobutamina nell'identificazione del miocardio vitale dopo infarto acuto del miocardio.

  4. Spectrophotometric determination of Sn+2 in lyophilized kit for labeling with 99mTc

    International Nuclear Information System (INIS)

    Araujo, Elaine Bortoleti; Sampel, Carolina Judith; Melo, Ivani Bortoleti; Okamoto, Miriam R.Y; Silva, Constancia P.G

    2004-01-01

    The preparation of 99 mTc labeled radiopharmaceuticals depends on the reduction of the technetium pertechnetate, commonly by stannous chloride (SnCl 2 ). The determination of the Sn +2 contents in the lyophilized preparations represents an important quality control procedure that may be applied to the process and to the final product. The objective os this work is the optimization of an spectrophotometric assay to the determination os Sn +2 contents in a citrate-stannous lyophilized kit for 99 mTc labeling. The spectrophotometric methodology employed is based in the colour development when Sn +2 reacts with sodium molybdate in the presence of potasium thiocyanate in chloridric medium. The colourfull reaction studied showed high stability after 60 minutes of the mixtures preparation. The sequence of reagents introduction in the reaction mixture was determinant to the assay. The molibdenium-stannous-tiocianate sequence produces calibration curves with good correlations (R2 ≥ 0.99). The concentrations of the molibdenium solution was also studied, in order to determine a ideal concentration for the Sn +2 range. The spectrophotometric method studied was usefull to the determination of Sn +2 content in different batches of citrate-stannous preparations. The method was fast and easy and can be applied to different stages of the production process, in order to guarantee the content of Sn +2 in the preparations (Au)

  5. Solvent extraction technology of 90Mo-sup(99m)Tc system: design and operational considerations

    International Nuclear Information System (INIS)

    Noronha, O.P.D.; Sewatkar, A.B.

    1983-01-01

    The design features of 99 Mo-sup(99m)Tc solvent extraction system have been reviewed. An improved semi-automated system has been improvised using the basic equipment of an indigenous unit along with other accessories, and with an added element of radiation protection to handle daily about 300-600 millicurie amounts of reactor-produced very low specific activity 99 Mo. The system has been used routinely for obtaining sup(99m)TcO 4 - - required for diagnostic purposes in nuclear medicine for the last twelve years. The performance characteristics of this unit with respect to yield and purity of 99 TcO 4 - - consistency of the process, the radiation dose to personnel and related health physics aspects have been evaluated. (author)

  6. Cyclotron Production of Technetium-99m

    Science.gov (United States)

    Gagnon, Katherine M.

    Technetium-99m (99mTc) has emerged as the most widely used radionuclide in medicine and is currently obtained from a 99Mo/ 99mTc generator system. At present, there are only a handful of ageing reactors worldwide capable of producing large quantities of the parent isotope, 99Mo, and owing to the ever growing shutdown periods for maintenance and repair of these ageing reactors, the reliable supply 99mTc has been compromised in recent years. With an interest in alternative strategies for producing this key medical isotope, this thesis focuses on several technical challenges related to the direct cyclotron production of 99mTc via the 100Mo(p,2n)99mTc reaction. In addition to evaluating the 100Mo(p,2n)99mTc and 100Mo(p,x)99Mo reactions, this work presented the first experimental evaluation of the 100Mo(p,2n) 99gTc excitation function in the range of 8-18 MeV. Thick target calculations suggested that large quantities of cyclotron-produced 99mTc may be possible. For example, a 6 hr irradiation at 500 μA with an energy window of 18→10 MeV is expected to yield 1.15 TBq of 99mTc. The level of coproduced 99gTc contaminant was found to be on par with the current 99Mo/99mTc generator standard eluted with a 24 hr frequency. Highly enriched 100Mo was required as the target material for 99mTc production and a process for recycling of this expensive material is presented. An 87% recovery yield is reported, including metallic target preparation, irradiation, 99mTc extraction, molybdate isolation, and finally hydrogen reduction to the metal. Further improvements are expected with additional optimization experiments. A method for forming structurally stable metallic molybdenum targets has also been developed. These targets are capable of withstanding more than a kilowatt of beam power and the reliable production and extraction of Curie quantities of 99mTc has been demonstrated. With the end-goal of using the cyclotron-produced 99mTc clinically, the quality of the cyclotron

  7. Comparison of /sup 99m/Tc diethyl-iminodiacetic acid and 131I rose bengal for hepatobiliary studies in liver-transplant patients: concise communication

    International Nuclear Information System (INIS)

    Klingensmith, W.C. III; Fritzberg, A.R.; Koep, L.J.

    1979-01-01

    Previous animal studies indicate that technetium-99m N,α-(2,6-diethylacetanilide)-iminodiacetic acid (/sup 99m/Tc diethyl-IDA) is superior to 131 I rose bengal ( 131 I RB) in most, but not all, physiologic parameters. Technetium-99m diethyl-IDA has a faster blood clearance, greater hepatic clearance, and a shorter hepatocyte transit time, but 131 I RB exhibits less renal clearance. We evaluated the relative merits of /sup 99m/Tc-diethyl-IDA and 131 I RB in paired studies in ten liver-transplant patients. Technetium-99m diethyl-IDA images were superior to 131 I RB images in demonstrating: (1) the liver parenchyma, (2) intrahepatic ducts, (3) small-bowel activity early after injection, and (4) in a smaller number of comparisons, colonic activity at 24 hr after injection. In addition, the percentage of dose excreted in the urine in 3 h for both radiopharmaceuticals was measured in 19 patients (total serum bilirubin range: 0.5 to 22.4 mg/dl). The percentage of dose of/sup 99m/Tc diethyl-IDA excreted in the urine averaged 7.5 in patients with normal total bilirubin levels and increased significantly with increasing total bilirubin levels. In the case of 131 I RB, normal patients averaged 4.9% of the injected dose in the urine and there was no increase with increasing total bilirubin levels. It is concluded that (1) /sup 99m/TC diethyl-IDA is superior to 131 I RB for imaging the hepatobiliary system, and (2) renal excretion of 131 I RB, unlike that of /sup 99m/Tc diethyl-IDA, is relatively unaffected by the total serum bilirubin level during the first 3 h after injection

  8. A modified method for the in vivo labeling of red blood cells with /sup 99m/Tc: concise communication

    International Nuclear Information System (INIS)

    Callahan, R.J.; Froelich, J.W.; McKusick, K.A.; Leppo, J.; Strauss, H.W.

    1982-01-01

    The rate of incorporation of /sup 99m/Tc into red blood cells pretinned in vivo was measured by collecting blood samples in stannous DTPA solution, which served as a competing ligand for /sup 99m/Tc. This collection technique permitted a measurement of high-affinity red-cell labeling efficiency at the instant of sampling. At 0.5 min after injection only 62% of technetium is tightly bound to the red cell; this rises to 94.5% at 10 min. Based on the graded labeling of the red cells, the in vivo labeling procedure was modified by isolating pertechnetate and red blood cells tinned in vivo in a syringe during the first 10 min of labeling. The pertechnetate is thus prevented from distributing to extravascular compartments, and 90% of the injected /sup 99m/Tc is firmly bound to red blood cells at the time of injection. In a series of 23 patients, seven were tested with the in vivo method and seven with the modified in vivo method, and nine patients were tested with each method on separate occasions. A decrease in gastric activity and improved image quality were found with the modified method compared with the standard method of in vivo red-cell labeling

  9. Scintigraphies after renal transplant: study of transplant function and of sup(99m)Tc labelled lymphocytes transit

    Energy Technology Data Exchange (ETDEWEB)

    Guey, A; Touraine, J L; Collard, M; Traeger, J [Institut National de la Sante et de la Recherche Medicale (INSERM), Hopital Edouard-Herriot, 69 - Lyon (France)

    1977-01-01

    In a first series of scintigraphic investigations in patients with a renal transplant, 'conventional' tracers, were used (sup(99m)Tc pertechnetate and sodium iodohippurate iodine-131) and they gave insight on alteration of the function of the transplanted kidney. Precisions on scintigraphic criteria of diagnosis of vascular complications and urinary fistulae were obtained but no clear cut discrimination between ischemic acute tubular necrosis and early rejection was apparent. Despite the use of a data acquisition and processing system (SCINTI-16) and despite improved functional characterization of the transplant, such methods do not appear to provide definite criteria for an early diagnosis of acute rejection. A different approach, using lymphocytes as a vector, was investigated. A method for lymphocyte labelling with sup(99m)Tc was developed. Labelled autologous lymphocytes were injected to normal volunteers and to patients, then the body distribution was determined and followed over a period of 24 hours. The activity was more precisely quantified at the site of the transplant, repeatedly for 24 hours following injection, and the resulting curves were altered in phases of preclinical rejection. The lymphocyte transit in the kidney would be slower during acute rejection crises of the transplanted kidney and this might be responsible for the different aspect of the curve, especially at 3 to 5 hours. This working hypothesis, will be analysed and documented, using more precise quantifications (close selection of the studied area), evaluating the intrarenal transit of each lymphocyte subpopulation and accurately measuring isotope release. It will then perhaps be possible to define very precise and precocious criteria of rejection.

  10. [sup 99]Tc[sup m]-MIBI single photon emission tomography (SPET) for detecting myocardial ischaemia and necrosis in patients with significant coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Sciammarella, M.G.; Fragasso, G.; Gerundini, P.; Maffioli, L.; Cappelletti, A.; Margonato, A.; Savi, A.; Chierchia, S. (Istituto Scientifico H San Raffaele, Milan (Italy). Dept. of Nuclear Medicine)

    1992-12-01

    The ability of [sup 99]Tc[sup m]-methoxyisobutylisonitrile (MIBI) single photon emission tomography (SPET) to detect myocardial ischaemia and necrosis was assessed in 56 patients with clinically recognised ischaemic heart disease (IHD). All underwent coronary angiography (CA) and left ventriculography (LV). SPET images were obtained at rest and at peak exercise 90 min after injection of [sup 99]Tc[sup m]-MIBI. The presence of persistent (P) or reversible (R) perfusion defects (PD) was then correlated to the resting and exercise ECG and to the results of CA and LV. Of the 56 patients, 34 had reversible underperfusion (RPD), 46 persistent underperfusion (PPD) and 31 had both. The occurrence of RPD correlated well with the occurrence of exercise-induced ST segment depression and/or angina (27 patients of 34 patients, 79%) and with the presence of significant coronary artery disease (CAD) (33 of 44, 73%). In 45 of 46 patients (98%) PPD corresponded to akinetic or severely hypokinetic segments (LV) usually explored by ECG leads exhibiting diagnostic Q waves (42 of 46 patients, 91%). The scan was normal both at rest and after stress in four of 11 patients with no CAD, and in two of 45 patients with CAD. Finally, an abnormal resting scan was seen in seven of 11 patients with normal coronary arteries, of whom six had regional wall motion abnormalities. In conclusion, MIBI SPET is a highly reliable technique for assessing the presence and location of myocardial ischaemia and necrosis. (Author).

  11. Evaluation of aptamers labelled with {sup 99m}Tc for identification of Staphylococcus aureus bacteria; Avaliacao de aptameros marcados com {sup 99m}Tc para identificacao de focos infecciosos de Staphylococcus aureus

    Energy Technology Data Exchange (ETDEWEB)

    dos Santos, Sara Roberta

    2014-06-01

    Staphylococcus aureus is specie of great medical importance because it is often associated with many infections in humans. This bacterium can cause diseases ranging from simple infections to life-threatening infections such as endocarditis, pneumonia, meningitis, toxic shock syndrome, septicemia, osteomyelitis, among others. S. aureus is the most commonly agent found in infections of the skin and soft tissues, bone infections and bone prostheses. The difficulty in early detection of specific foci caused by bacteria has raised the need to search for new techniques for this purpose. Diagnosis by scintigraphy has advantages over other methods because it is able to identify damage tissues without the need of invasive procedures and is able to perform an early diagnosis even before anatomic changes. Thus, nuclear medicine could contribute to an accurate diagnosis of bacterial infections, since specific radiopharmaceuticals were developed. Aptamers are oligonucleotides that have high affinity and specificity for their molecular targets and are emerging as a new class of molecules for radiopharmaceuticals development. Radiolabeled aptamers specific to the infectious agents, could give a significant contribution to the infection diagnosis by scintigraphy. In this study, aptamers selected to S. aureus were labeled with {sup 99m}Tc and used for the bacteria identification in vitro and in vivo. The aptamers labeled with {sup 32}P and incubated in vitro with S. aureus cells showed high affinity for the bacterial cells when compared with the library of oligonucleotides with random sequences used as control. The aptamers labeled with {sup 99m}Tc also showed affinity for S. aureus cells when compared with the library, but unspecific binding was also verified. The {sup 99m}Tc labelled aptamers were stable in 0.9% saline, plasma of Swiss mice and in excess of cysteine. The in vivo biodistribution studies using Swiss mice with intramuscular infection in the right thigh showed that

  12. Immediate renal imaging and renography with /sup 99m/Tc methylene diphosphonate to assess renal blood flow, excretory function, and anatomy

    International Nuclear Information System (INIS)

    Glass, E.C.; DeNardo, G.L.; Hines, H.H.

    1980-01-01

    /sup 99m/Tc methylene diphosphonate (/sup 99m/Tc MDP) was evaluated as a clinical renal imaging agent in 20 patients referred for bone scintigraphy. Sequential scintigraphy, which was started immediately after injection, yielded blood flow studies of high quality, and subsequent images accurately delineated renal anatomy and excretion in nonazotemic patients. In comparison with delayed images, early images were vastly superior in quality and demonstrated improved target-to-nontarget activity ratios (p < 0.001) and improved lesion detectability (p < 0.01). Renal imaging performed incidental to bone scintigraphy with MDP can be greatly enhanced by initiating sequential scintigraphy immediately after injection

  13. Simultaneous acquisition of (99m)Tc- and (123)I-labeled radiotracers using a preclinical SPECT scanner with CZT detectors.

    Science.gov (United States)

    Kobayashi, Masato; Matsunari, Ichiro; Nishi, Kodai; Mizutani, Asuka; Miyazaki, Yoshiharu; Ogai, Kazuhiro; Sugama, Jyunko; Shiba, Kazuhiro; Kawai, Keiichi; Kinuya, Seigo

    2016-05-01

    Simultaneous acquisition of (99m)Tc and (123)I was evaluated using a preclinical SPECT scanner with cadmium zinc telluride (CZT)-based detectors. 10-ml cylindrical syringes contained about 37 MBq (99m)Tc-tetrofosmin ((99m)Tc-TF) or 37 MBq (123)I-15-(p-iodophenyl)-3R,S-methyl pentadecanoic acid ((123)I-BMIPP) were used to assess the relationship between these SPECT radioactive counts and radioactivity. Two 10-ml syringes contained 100 or 300 MBq (99m)Tc-TF and 100 MBq (123)I-BMIPP to assess the influence of (99m)Tc upscatter and (123)I downscatter, respectively. A rat-sized cylindrical phantom also contained both 100 or 300 MBq (99m)Tc-TF and 100 MBq (123)I-BMIPP. The two 10-ml syringes and phantom were scanned using a pinhole collimator for rats. Myocardial infarction model rats were examined using 300 MBq (99m)Tc-TF and 100 MBq (123)I-BMIPP. Two 1-ml syringes contained 105 MBq (99m)Tc-labeled hexamethylpropyleneamine oxime ((99m)Tc-HMPAO) and 35 MBq (123)I-labeled N-ω-fluoropropyl-2β-carbomethoxy-3β-(4-iodophenyl) nortropane ((123)I-FP-CIT). The two 1-ml syringes were scanned using a pinhole collimator for mice. Normal mice were examined using 105 MBq (99m)Tc-HMPAO and 35 MBq (123)I-FP-CIT. The relationship between SPECT radioactive counts and radioactivity was excellent. Downscatter contamination of (123)I-BMIPP exhibited fewer radioactive counts for 300 MBq (99m)Tc-TF without scatter correction (SC) in 125-150 keV. There was no upscatter contamination of (99m)Tc-TF in 150-175 keV. In the rat-sized phantom, the radioactive count ratio decreased to 4.0 % for 300 MBq (99m)Tc-TF without SC in 125-150 keV. In the rats, myocardial images and radioactive counts of (99m)Tc-TF with the dual tracer were identical to those of the (99m)Tc-TF single injection. Downscatter contamination of (123)I-FP-CIT was 4.2 % without SC in 125-150 keV. In the first injection of (99m)Tc-HMPAO and second injection of (123)I-FP-CIT, brain images and radioactive counts

  14. Biodistribution studies of 99mTc-labeled myoblasts in a murine model of muscular dystrophy

    International Nuclear Information System (INIS)

    Colombo, F.R.; Torrente, Y.; Casati, R.; Benti, R.; Corti, S.; Salani, S.; D'Angelo, M.G.; DeLiso, A.; Scarlato, G.; Bresolin, N.; Gerundini, P.

    2001-01-01

    The purpose of this study was twofold: first, to evaluate the myoblast labeling of various 99m Tc complexes and to select the complex that best accomplishes this labeling, and second to evaluate the biodistribution of myoblasts labeled with this complex using mice with MDX muscular dystrophy (the murine homologue of Duchenne's muscular dystrophy). The following ligands were used to prepare the corresponding 99m Tc complexes: hexakis-methoxy-isobutyl-isonitrile (MIBI), bis(2-ethoxyethyl)diphosphinoethane (Tf), (RR,SS)-4,8-diaza-3,6,6,9-tetramethyl-undecane-2,10-dione-bisoxime (HM-PAO), bis(N-ethyl)dithiocarbamate (NEt), and bis(N-ethoxy, N-ethyl)dithiocarbamate (NOEt). One million murine myoblasts were incubated for 30-60 minutes with 5 mCi of each of the 99mTc complexes prepared from the above ligands. Viability was assessed by microscopic counting after trypan blue staining, and the radioactivity absorbed in the cells was measured after centrifugation. The compound with the highest uptake in cellular pellets was [ 99m Tc]N-NOEt. The biodistribution of myoblasts labeled with this complex was evaluated after intraaortic injection in dystrophic mice. Such an approach has the potential of effecting widespread gene transfer through the bloodstream to muscles lacking dystrophin

  15. Radionuclide study of thyroid function in pediatrics, using sup(99m)Tc, /sup 123/I or /sup 131/I: 150 case-reports

    Energy Technology Data Exchange (ETDEWEB)

    Guillet, J.; Basse-Cathalinat, B.; Soubiran, G.; Blanquet, P. (Hopital Pellegrin, 33 - Bordeaux (France)); Guillet, G. (Johns Hopkins Medical Institutions, Baltimore, MD (USA). Div. of Nuclear Medicine)

    1981-11-01

    THe best radioisotope for in vivo thyroid investigations is the one which provides the highest quality scintigrams with the least radiation exposure. The choice of /sup 131/I, /sup 123/I or sup(99m)Tc in 150 children is discussed. Cases included 25 dysgenesis, 4 goiters with hypothyroidism, 56 goiters without thyroid dysfunction, 3 thyroiditis, and 11 cold nodules. When thyroid scanning is performed with /sup 131/I, the gland's radiation exposure is high. /sup 123/I is preferable since a fairly high activity can be obtained without delivering an excessive radiation dose. (approximately 2 rad to the thyroid for 50 microCi/m/sup 2/). sup(99m)Tc which is readily available is not a true iodine analog. It does not give a true picture of iodine metabolism. /sup 123/I was generally used in cases of hypothyroidism, goiter (whenever a defect in thyroid hormone synthesis was suspected) and hyperthyroidism. sup(99m)Tc was generally used in other cases. The low radiation doses delivered by these radioisotopes allows study of thyroid function in the neonate.

  16. Comparative uptake of Tc-99m sestamibi and Tc-99m tetrofosmin in cancer cells and tissue expressing P-Glycoprotein or multidrug resistance associated protein

    International Nuclear Information System (INIS)

    Cho, Jung Ah; Lee, Jae Tae; Yoo, Jung Ah

    2005-01-01

    99m Tc-sestamibi(MIBI) and 99m Tc-tetrofosmin have been used as substrates for P-glycoprotein (Pgp) and multidrug resistance associated protein (MRP), which are closely associated with multidrug resistance of the tumors. To understand different handling of radiotracers in cancer cell lines expressing Pgp and MRP, we compared cellular uptakes of 99m Tc-MIBI and 99m Tc-tetrofosmin. The effects of cyclosporin A (CsA), well-known multidrug resistant reversing agent, on the uptake of both tracers were also compared. HCT15/CL02 human colorectal cancer cells for Pgp expressing cells, and human non-small cell lung cancer A549 cells for MRP expressing cells, were used for in vitro and in vivo studies. RT-PCR, western blot analysis and immunohistochemistry were used for detection of Pgp and MRP. MDR-reversal effect with CsA was evaluated at different drug concentrations after incubation with MIBI or tetrofosmin. Radioactivities of supernatant and pellet were measured with gamma well counter. Tumoral uptake of the tracers were measured from tumor bearing nude mice treated with or without CsA. RT-PCR, western blot analysis of the cells and immunochemical staining revealed selective expression of Pgp and MRP for HCT15/CL02 and A549 cells, respectively. There were no significant difference in cellular uptakes of both tracers in HCT15/CL02 cells, but MIBI uptake was slightly higher than that of tetrofosmin in A549 cells. Co-incubation with CsA resulted in a increase in cellular uptakes of MIBI and tetrofosmin. Uptake of MIBI or tetrofosmin in HCT15/CL02 cells was increased by 10-and 2.4-fold, and by 7.5 and 6.3-fold in A549 cells, respectively. Percentage increase of MIBI was higher than that of tetrofosmin with CsA for both cells (ρ < 0.05). In vivo biodistribution study showed that MIBI (114% at 10 min, 257% at 60 min, 396% at 24C min) and tetrofosmin uptake (110% at 10 min, 205% at 60 min, 410% at 240 min) were progressively increased by the time, up to 240 min with CsA. But

  17. Comparative uptake of Tc-99m sestamibi and Tc-99m tetrofosmin in cancer cells and tissue expressing P-Glycoprotein or multidrug resistance associated protein

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jung Ah; Lee, Jae Tae; Yoo, Jung Ah [School of Medicine, Kyungpook National University, Daegu (Korea, Republic of)] (and others)

    2005-02-15

    {sup 99m}Tc-sestamibi(MIBI) and {sup 99m}Tc-tetrofosmin have been used as substrates for P-glycoprotein (Pgp) and multidrug resistance associated protein (MRP), which are closely associated with multidrug resistance of the tumors. To understand different handling of radiotracers in cancer cell lines expressing Pgp and MRP, we compared cellular uptakes of {sup 99m}Tc-MIBI and {sup 99m}Tc-tetrofosmin. The effects of cyclosporin A (CsA), well-known multidrug resistant reversing agent, on the uptake of both tracers were also compared. HCT15/CL02 human colorectal cancer cells for Pgp expressing cells, and human non-small cell lung cancer A549 cells for MRP expressing cells, were used for in vitro and in vivo studies. RT-PCR, western blot analysis and immunohistochemistry were used for detection of Pgp and MRP. MDR-reversal effect with CsA was evaluated at different drug concentrations after incubation with MIBI or tetrofosmin. Radioactivities of supernatant and pellet were measured with gamma well counter. Tumoral uptake of the tracers were measured from tumor bearing nude mice treated with or without CsA. RT-PCR, western blot analysis of the cells and immunochemical staining revealed selective expression of Pgp and MRP for HCT15/CL02 and A549 cells, respectively. There were no significant difference in cellular uptakes of both tracers in HCT15/CL02 cells, but MIBI uptake was slightly higher than that of tetrofosmin in A549 cells. Co-incubation with CsA resulted in a increase in cellular uptakes of MIBI and tetrofosmin. Uptake of MIBI or tetrofosmin in HCT15/CL02 cells was increased by 10-and 2.4-fold, and by 7.5 and 6.3-fold in A549 cells, respectively. Percentage increase of MIBI was higher than that of tetrofosmin with CsA for both cells ({rho} < 0.05). In vivo biodistribution study showed that MIBI (114% at 10 min, 257% at 60 min, 396% at 24C min) and tetrofosmin uptake (110% at 10 min, 205% at 60 min, 410% at 240 min) were progressively increased by the time, up to

  18. Survey of /sup 99m/Tc contamination of laboratory personnel: hand decontamination

    International Nuclear Information System (INIS)

    Nishiyama, H.; Van Tuinen, R.J.; Lukes, S.J.; Feller, P.A.

    1980-01-01

    Decontamination after exposure to various /sup 99m/Tc radiopharmaceuticals was tested with serial hand washings both with and without soap. All radiopharmaceuticals were removed more effectively with soap and the degree of decontamination related closely to the number of washings. The affinity of the radiopharmaceuticals for the skin varied, depending upon the labeled material, and only macroaggregated albumin was effectively removed to less than 1% of its original activity with soap. Activity transfer to the opposite hand could be substantial with macroaggregated albumin and sulfur colloid if soap is not used

  19. Clinical value of atropine-four minutes adenosine stressed 99Tcm-MIBI myocardial perfusion imaging in the diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Peng Xulan; Zhang Baoniu; Jiang Sufang; Liang Hongwei; Liu Jun; Gao Guizhu; Ding Minghui; Hou Junfu

    2008-01-01

    Objective: The aim of this study was to compare the diagnostic efficacy of atropine-4 min adenosine stressed 99 Tc m -methoxyisobutylisonitrile (MIBI) myocardial perfusion imaging in the diagnosis of coronary artery disease (CAD). Methods: A total of 56 patients were divided into atropine-4 min adenosine stress (research group) and 6 min adenosine infusion (control group). The sex, age, the severity of CAD (judged by coronary, angiography) and associated symptoms were matched between the 2 groups. In research group, 0.5 mg atropine was injected intravenously 10 min before adenosine infusion. Adenosine was infused at a rate of 0.14 mg·kg -1 ·min -1 intravenously for 4 min and 6 min in research and control groups. At 3 min after adenosine infusion, 740 MBq 99 Tc m -MIBI was injected. SPECT myocardial imaging was obtained 1.5 h later. A rest myocardial perfusion imaging was performed on the following day. Results: (1) In research group and control group, the sensitivity, specificity, diagnostic accuracy was 85%, 6/8, 82% and 86%, 5/7, 82%, respectively (χ 2 0.05). (2)The sensitivity of the adenosine test for detection of single vessel, two vessels, three vessels disease were 6/7, 8/9, 3/4 and 7/8, 7/8, 4/5 in research group and control group, respectively(χ 2 0.05). (3) Side affects occurred in 82% of the patients in the research group and in 89% of the patients in the control group. The incidence of side effects in the two groups was not significantly different besides chest depression (43% and 68%, χ 2 =4.000, <0.05). Conclusions: Atropine-4 min adenosine infusion, in combination with perfusion tomography, has similar diagnostic efficacy for CAD to the 6 min protocol, and has lower incidence of chest depression than the standard 6 min infusion. (authors)

  20. Resting technetium-99m methoxyisobutylisonitrile cardiac imaging in chronic coronary artery disease: comparison with rest-redistribution thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Cuocolo, A.; Maurea, S.; Pace, L.; Nicolai, E.; Nappi, A.; Imbriaco, M.; Trimarco, B.; Salvatore, M.

    1993-01-01

    We studied 19 patients with angiographically proven coronary artery disease and left ventricular dysfunction (ejection fraction 33%±8%) by resting technetium-99m methoxyisobutylisonitrile ( 99m Tc-MIBI) and rest-redistribution thallium-201 cardiac imaging. Thallium and 99m Tc-MIBI studies were visually analysed. Of 285 segments, 203 (71%) had normal thallium uptake, 48 (17%) showed reversible thallium defects and 34 (12%) showed irreversible thallium defects. Of these 34 irreversible thallium defects, 19 (56%) were moderate and 15 (44%) were severe. Of the corresponding 285 segments, 200 (70%) had normal 99m Tc-MIBI uptake, while 37 (13%) showed moderate and 48 (17%) showed severe reduction of MIBI uptake. Myocardial segmental agreement for regional uptake score between initial thallium and resting 99m Tc-MIBI images was 90% (κ=0.78). Segmental agreement between delayed thallium and resting 99m Tc-MIBI images was 77% (κ=0.44). In particular, in 26 (9%) segments 99m Tc-MIBI uptake was severely reduced while delayed thallium uptake was normal or only moderately reduced. These data suggest that although rest-redistribution thallium and resting 99m Tc-MIBI cardiac imaging provide concordant results in the majority of myocardial segments, some segments with severely reduced resting 99m Tc-MIBI uptake may contain viable but hypoperfused myocardium. Thus, conclusions on myocardial viability based on 99m Tc-MIBI uptake should be made with caution in chronic coronary artery disease. (orig.)

  1. Stability 'in vivo' and 'in vitro' of the diisopropyl-IDA sup(99m)Tc

    International Nuclear Information System (INIS)

    Verdera, E.S.; Leon, A.S.; Robles, A.M.; Correa, Angela; Oliver, Guillermo; Gamma, Santos; Lanzzeri, Stella; Mitta, A.E.A.

    1982-01-01

    The 'in vitro' and 'in vivo' stability of the diisopropyl (IDA-3) kit in solution and of the molecule labelled with sup(99m)Tc was studied. The following items were studied a) shelf life of the kit in solution b) 'in vitro' stability of the labelled molecule c) distribution and elimination kinetics d) identification and behaviour of the excretion products. Chromatographic control shows 95% yield of labelled product after 20 days storage at 4 deg C and 92% yield after 30 days in the same conditions; biological distribution was good in both cases. Regarding the 'in vitro' stability, no alteration was observed within the 4 hours after its preparation. The stability of the complex was determined by the reaction between sup(99m)TcIDA-3 and DTPA. Analysis by electrophoresis shows the complex to be stable even with DTPA concentrations 5 times higher. Kinetics of distribution and elimination of the labelled molecule, in animals, were afterwards confirmed by sequential scintigraphic images in humans. The excretion of unaltered sup(99m)Tc-IDA by biliary and urinary ways was confirmed by cromatographic and electrophoretic analysis of bladder and gall bladder content and by determination of its biological distribution. (author) [es

  2. Design and setup of a portable stirring device for transfer and dissolution of {sup 99}Mo applied to the use of a {sup 99m}Tc generator; Diseno e implementacion de un modulo portatil para el traslado y disolucion de Mo-99 aplicado al empleo de un generador de Tc-99m

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, Yon [Universidad Nacional de Ingenieria, Lima (Peru). Facultad de Ingenieria Mecanica; Urquizo, Rafael [Universidad Tecnologica del Peru, Lima (Peru). Facultad de Ingenieria de Sistemas y Electronica; Mendoza, Pablo [Direccion de Investigacion y Desarrollo, Instituto Peruano de Energia Nuclear, Lima (Peru); Rojas, Jorge [Universidad Nacional Mayor San Marcos, Lima (Peru). Facultad de Quimica e Ingenieria Quimica

    2014-07-01

    This work shows the design and implementation of a portable magnetic stirring device for transfer and efficient dissolution of Mo{sub O}3 coupled to a {sup 99m}Tc generator prototype. The development of this equipment will enable an efficient and safe transfer of {sup 99}Mo at a 2 Ci of maximum activity from the nuclear reactor Huarangal to the point of operation of the {sup 99m}Tc generator equipment. This article describes the mechanical design, volume and shielding calculation, the electronics design and the programmable speed control of the stirring system for radioactive samples. (authors).

  3. Utility of the tetrophosmine-{sup 99m}Tc in the determination of malignant tumours located in the muscle-skeletal system, preliminary report; Utilidad de la tetrofosmina-{sup 99m}Tc en la determinacion de malignidad de tumores localizados en el sistema musculoesqueletico, reporte preliminar

    Energy Technology Data Exchange (ETDEWEB)

    Garcia R, J C; Gonzalez, I F; Rico, G; Linares, L M; Delgado C, E; Baena, L [Centro Nacional de Rehabilitacion, Mexico D.F. (Mexico); Adame, G; Gonzalez R, D [MIYMSA, Mexico D.F. (Mexico); Perez C, J P; Valencia, S [Hospital medica Sur, Mexico D.F. (Mexico)

    2005-07-01

    From its authorization by the FDA, as radiopharmaceutical to be used in studies of myocardial perfusion, multiple articles have appeared in the literature it prescribes that its validate the use of the tetrophosmine-{sup 99m}Tc in the valuation of different tumors, so much in the determination of malignancy, like in the evolution and in the response to the treatment. For that reason the objective of this protocol is to evaluate the utility of the tetrophosmine- {sup 99m}Tc in the determination of malignancy in non treated tumors located in the skeletal muscle system, in a population of 40 patients coming from the service of bony tumors of the National Center of Rehabilitation. For the time being its report the discoveries in 27 studies. (Author)

  4. Comparative evaluation of 123I and /sup 99m/Tc for thyroid studies

    International Nuclear Information System (INIS)

    Atkins, H.L.; Ansari, A.N.; Bradley-Moore, P.R.; Lambrecht, R.; Wolf, A.

    1975-01-01

    Both /sup 99m/Tc and 123 I can be used to advantage in assessing thyroid function and anatomy. The nuclides have similar principal gamma photons, and their short physical half-lives result in low radiation dose, thus allowing administration of large quantities of activity. The very early uptakes of these radionuclides by the thyroid do not bear a consistent relationship, and that requires further study. The clinical value of 123 I depends ultimately on its consistent availability at reasonable cost

  5. The diagnostic value of monoclonal antibody scan (leucoscan) compared with 99mTc MDP bone scan and Ga 67 in diagnosing bone and joint infection

    International Nuclear Information System (INIS)

    Koukouraki, S.I.; Velidaki, A.; Prassopoulos, V.; Karkavitsas, N.; Vavouranakis, H.; Hatjipavlou, A.

    2002-01-01

    Full text: Nowadays different radiopharmaceuticals have been developed as 99mTc MDP, 67Ga citrate, 111In oxine- and 99mTc HMPAO labeled leucocytes for the accurate localization of bone/joint infection, but all of them have limitations that encouraged the search of new agents characterized from high and early uptake in infectious/inflammatory tissues, low toxicity and no accumulation in non inflamed tissues. The purpose of this study is to compare the diagnostic value of a 99mTc labeled antigranulocyte Fab' fragment (Leucoscan) with 99mTc MDP bone scan and 67 Ga. The monoclonal antibody, Leucoscan, is an IgG murine Fab' fragment directed against a NCA-90 epitope located on the surface of granulocytes. 45 patients with suspected bone and joint infection (18 total hip prosthesis, 4 knee prosthesis, 8 vertebral infection and 15 long bones) were included in this study. All patients underwent conventional Rx, bone scan, 67Ga scan and Leucoscan. Three phase 99mTc MDP bone scan and 67Ga scan were performed using standard procedures. For Leucoscan the antibody was labeled with 25 mCi of 99mTc and was infected intravenously over 30 seconds. Ten minutes planar images were taken 1 h and 2 hrs p.i using a GE Millennium γ camera provided with a LEGP collimator. Images were evaluated as score 1 (no abnormal uptake), score 2 (probably positive), score 3 (definitely infected) according the intensity of abnormally increased uptake. Results were compared with 99mTc MDP bone scan and 67Ga scans. The final diagnosis was given by the surgical verification with histopathology or culture. All 45 patients had pathologic proof of presence/absence of bone and joint infection. 36/45 were positive for bone or joint infection and 9/45 were negative.30/36 patients with surgically proven bone and joint infection had true positive Leucoscan, 26/36 had true positive MDP bone scan and 20/36 true positive 67Ga scan. Nine out of 9 patients with proven absence of inflammation had true negative

  6. Performance study of molybdenum gels with titanium for preparation of {sup 99}Mo-{sup 99m}Tc generators; Estudo do desempenho de geis de molibdenio com titanio no preparo de geradores de {sup 99}Mo-{sup 99m}Tc

    Energy Technology Data Exchange (ETDEWEB)

    Moraes, Vanessa; Osso Junior, Joao Alberto [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)]. E-mail: vmoraes@ipen.br

    2005-07-01

    {sup 99m}Tc is the most used radioisotope in Nuclear Medicine, due to nuclear characteristics. It is obtained by the radioactive decay of {sup 99}Mo, generator of radioisotope system. When {sup 99}Mo is produced by the activation in reactor, the most used technique for the preparation of the generators is the gel type generator, which incorporates {sup 99}Mo to the gel that is insoluble, chemically inert to the solutions and with properties of ion exchange. Several countries had already studied this methodology, as is the case of Vietnam, India, China, Australian. This work has the objective of studying the performance and characterization of molybdenum gels with titanium. Four variables in the preparation of the gel were studied: mass ratio between Mo and Ti (1.80 and 2.25), concentration of NaOH (2 and 4 mol/L), final temperature (25 and 50 deg C) and pH (3.5 and 4.5). The prepared gels were analyzed with relation to the size of its particles, identification of its structure, amount of molybdenum, amount of titanium, profile of elution, pH of the elution, determination of the radioisotopes in the eluate and final radiochemical purity. The final result is a formularization of the gel with the best characteristics for posterior preparation of the generator of {sup 99m}Tc-{sup 99}Mo. (author)

  7. Myocardial impairment detected by late gadolinium enhancement in hypertrophic cardiomyopathy: comparison with 99mTc-MIBI/tetrofosmin and 123I-BMIPP SPECT.

    Science.gov (United States)

    Hashimura, Hiromi; Kiso, Keisuke; Yamada, Naoaki; Kono, Atsushi; Morita, Yoshiaki; Fukushima, Kazuto; Higashi, Masahiro; Noguchi, Teruo; Ishibashi-Ueda, Hatsue; Naito, Hiroaki; Sugimura, Kazuro

    2013-06-17

    Myocardial fibrosis is considered to be an important factor in myocardial dysfunction and sudden cardiac death in hypertrophic cardiomyopathy (HCM). The purpose of this study was to compare myocardial fibrosis detected by late gadolinium enhancement (LGE) on cardiac MRI with myocardial perfusion and fatty acid metabolism assessed by single photon emission computed tomography in HCM. We retrospectively evaluated 20 consecutive HCM patients (female, 7; mean age, 53.4 years) who underwent LGE, technetium-99m methoxyisobutylisonitrile/tetrofosmin (99mTc-MIBI/tetrofosmin), and iodine-123 beta-methyl-iodophenylpentadecanoic acid (123I-BMIPP) imaging. We calculated the myocardium-to-lumen signal ratio (M/L) for LGE in 17 segments based on the American Heart Association statement. Scoring of 99mTc-MIBI/tetrofosmin (PI) and 123I-BMIPP (BM) was performed for each segment using a 5-point scale (0, normal; 4, highly decreased). Nineteen of 20 patients (95%) and 153 of 340 segments (45%) showed LGE. M/Ls were 0.42±0.16, 0.55±0.17, and 0.65±0.24 in PI0/BM0, PI0/BM1-4 and PI1-4/BM1-4, respectively. All M/Ls were significantly higher than that of a normal control (0.34±0.14) (pacid metabolism, and is more strongly associated with disorders of fatty acid metabolism than with perfusion abnormalities. M/L may be a useful indicator of disease severity.

  8. 99mTc-MIBI radio-guided minimally invasive parathyroidectomy: experience with patients with normal thyroids and nodular goiters.

    Science.gov (United States)

    Casara, Dario; Rubello, Domenico; Cauzzo, Cristina; Pelizzo, Maria Rosa

    2002-01-01

    The surgical approach to primary hyperparathyroidism (HPT) is changing. In patients with a high probability to be affected by a solitary parathyroid adenoma (PA), a unilateral neck exploration (UNE) or a minimally invasive radio-guided surgery (MIRS) using the intraoperative gamma probe (IGP) technique have recently been proposed. We investigated the role of IGP in a group of 84 patients with primary HPT who were homogeneously evaluated before surgery by a single-day imaging protocol including 99mTcO4/MIBI subtraction scan and neck ultrasound (US) and then operated on by the same surgical team. Quick parathyroid hormone (QPTH) was intraoperatively measured in all cases to confirm successful parathyroidectomy. In 70 patients with scan/US evidence of a single enlarged parathyroid gland (EPG) and with a normal thyroid gland, MIRS was planned. In the other 14 patients, the IGP technique was utilized during a standard bilateral neck exploration (BNE) because of the presence of concomitant nodular goiter (11 cases) or multiglandular disease (MGD) (3 cases). The IGP technique consisted of the following: (1) in the operating room, a low 99mTc-MIBI dose (37 MBq) was injected intravenously during anesthesia induction; (2) subsequently, the patient's neck was scanned with the probe by the surgeon to localize the cutaneous projection of the EPG; (3) in patients who underwent MIRS, the EPG was detected intraoperatively with the probe and removed through a small, 2 to 2.5 cm skin incision; (4) radioactivity was measured on the EPG both in vivo and ex vivo, the thyroid, the background and the parathyroid bed after EPG removal. In patients with concomitant nodular goiter, the radioactivity was also measured on the thyroid nodules. Surgical and pathologic findings were consistent with a single PA in 78 patients, parathyroid carcinoma in 2, and MGD in 4. MIRS was successfully performed in 67 of the 70 patients (97.7%) in whom this approach was planned. It must be pointed out that

  9. Synthesis, Characterization and Biological Studies of 99mTc and 188Re Peptides

    Science.gov (United States)

    Sanders, Vanessa

    Radiopharmaceuticals are very powerful diagnostic tools for evaluation of a host of medical conditions. These drugs are labeled with radioactive isotopes, which are utilized to create pictures of areas of interest through absorption of the drug. They are currently in high demand due to their ability to image areas that traditional imaging devices cannot. The radioisotope 99mTc, with a half-life of 6.01 hours and a 140 keV gamma emission, is central to many radiopharmaceutical compounds. This isotope is easily obtained from a 99Mo-99mTc generator, through beta decay and column chromatography separations. Very little technetium, less than 6 ng, is needed to label the pharmaceuticals for use in-vivo. Another radioisotope 188Re is also important due to its ability to be used for therapy while being tracked throughout the body. Radiotherapy gives radiopharmaceuticals a huge advantage by their ability to destroy rapidly growing cells. One of the main reasons there is interest in rhenium pharmaceuticals is the chemical similarity between it and technetium. The 188Re isotope also has a considerably short half-life of approximately 17 hours and has emission energy of 155 keV. The 188Re isotope is separated from 188W-188Re generator, analogously to the 99Mo-99mTc generator. The ligand used in this work is a pentapepetide macrocyclic ligand. This ligand, KYCAR (lysyl-tyrosyl-cystyl-alanyl-arginine), has been designed as a potential chelating ligand for imaging and therapeutic in vivo agents. Ligands are chosen based on their in-situ biological behavior, and are used in the complexation with technetium and rhenium. Understanding and exploiting technetium and rhenium chemistry can provide insight into the reaction mechanisms and coordination chemistry of these compounds. The exploration of various oxidation states as a function of the ligands used and the reaction conditions can help develop novel radiopharmaceuticals. The investigations of the manipulation of oxidation states

  10. Production of the antimicrobial peptide UBI 29-41 labelled with 99mTc by an indirect method

    International Nuclear Information System (INIS)

    Nevares, Noemi; Crudo, Jose L.; Zapata, Miguel; Castiglia, Silvia G. de

    2003-01-01

    The infection processes are a major problem in human health causing a high number of human deaths all around the world. Diagnostic imaging in nuclear medicine is an attractive option in the detection of infection processes due to its sensitivity. The antimicrobial peptides are very important in the development of new radiopharmaceuticals, since their antimicrobial activity towards a great variety of microorganisms have been proven. The aim of this work was to obtain the antimicrobial peptide UBI 29-41 labelled with technetium 99 m, by an indirect method via NHS-Hynic and tricine as a coligand, and evaluate its stability and its ability to discriminate between infection and inflammation sites. The radiochemical purity of the labeling procedure was 95.5±1,2 %. The cysteine challenge showed a great stability of the 99mTc UBI-Hynic, and the stability in human serum showed that the 81% of the radioactivity remained bounded to UBI-Hynic at 48 hs of incubation. The bio distribution's studies showed main elimination via kidney of 99mTc UBI-Hynic and the target/non target ratio was 1,81 for infected mice and 1,16 for inflamed mice. (author)

  11. Labelling of m-trimethyl silylphenyl-ethylidene-1, i-bisphosphonate with /sup 99m/Tc and its evaluation as an imaging agent

    International Nuclear Information System (INIS)

    Sajid, K.M.; Mahmood, R.

    2012-01-01

    Technetium-99m labeled phosphates and phosphonates have since long been in use for bone imaging to diagnose bone infection, bone metastasis and bone fracture. /sup 131/ I -labeled bisphosphonates have also been prepared for targeted radiotherapy of bone metastasis. Although animal experiments show good accumulation of bisphosphonates in bone. The agent has never been tried in humans because of high gamma and beta energy. The agent must first be tested in humans using a relatively safe radioisotope. Technitium-99m (/sup 99m/Tc) a radioisotope with relatively low gamma energy 99m and short half-life can serve as a good label. Whether /sup 99m/Tc-labeled bisphosphonates can be used as good imaging agents is another aspect that needs further investigation. A study was therefore, conducted to label m-trimethyl silylphenyl)-ethylidene-1, 1-bisphosphonate with /sup 99m/Tc and standardize the labeling procedure. The labeling procedure - involved reduction of technetium (TcO/sub 4/) with stannous chloride followed by chelation of technetium with bisphosphonates. Radiochemical purity was checked by paper chromatography. Pyrogenicity was checked by administration of the labeled compound into rabbits. The stability of the compound was determined by noting the radiochemical binding at several intervals of half an hour after preparation. Biodistribution of the agent was studied by injecting the labeled compound into rabbits. The results showed that the compound could be labeled with /sup 99m/Tc without any difficulty. The ease of binding was excellent. There was more than 95% binding of technetium with the compound and the labelled compound was reasonably stable for 5 hours after labeling. The rectal temperature remained stable during this period, which showed that the animal accepted the compound and there were no pyrogenic reactions. Biodistribution studies on rabbit showed that accumulation of agent was poor in bones and the labeled compound remains in blood even after 4

  12. A case of parathyroid carcinoma visualized on Tc-99m-sestamibi scintigraphy

    International Nuclear Information System (INIS)

    Aigner, R.M.; Fueger, G.F.; Lax, S.

    1997-01-01

    Recent studies indicate that Tc-99m-Sestamibi (MIBI, DuPont Pharma) is a useful tracer for detecting parathyroid adenomas. We present a patient with focal Tc-99m-MIBI uptake in parathyroid carcinoma which has only been described once before (1). Tc-99m-MIBI scintigraphy may be considered for diagnosing pathological parathyroid tissue. But presently the histopathological examination only allows the differentiation between adenoma and carcinoma. (orig.) [de

  13. Sestamibi technetium-99m brain single-photon emission computed tomography to identify recurrent glioma in adults: 201 studies.

    Science.gov (United States)

    Le Jeune, Florence Prigent; Dubois, François; Blond, Serge; Steinling, Marc

    2006-04-01

    In the follow-up of treated gliomas, CT and MRI can often not differentiate radionecrosis from recurrent tumor. The aim of this study was to assess the interest of functional imaging with (99m)Tc-MIBI SPECT in a large series of 201 examinations. MIBI SPECT were performed in 81 patients treated for brain gliomas. A MIBI uptake index was computed as the ratio of counts in the lesion to counts in the controlateral region. SPECT was compared to stereotactic biopsy in 14 cases, or in the others cases to imaging evolution or clinical course at 6 months after the last tomoscintigraphy Two hundred and one tomoscintigraphies were performed. One hundred and two scans were true positive, 82 scans were true negative. Six scans were false positive (corresponding to 3 patients): 2 patients with an inflammatory reaction after radiosurgery, 1 with no explanation up to now. Eleven scans were false negative (5 patients): 1 patient with a deep peri-ventricular lesion, 2 patients with no contrast enhancement on MRI, 2 patients with a temporal tumor. The sensitivity for tumor recurrence was 90%, specificity 91.5% and accuracy 90.5%. We studied separately low and high grade glioma: sensitivity for tumor recurrence was respectively 91% and 89%, specificity 100% and 83% and accuracy 95% and 87%. MIBI SPECT allowed the diagnose of anaplasic degenerence of low grade sometimes earlier than clinical (5 cases) or MRI signs (7 cases). Our results confirm the usefullness of MIBI SPECT in the follow-up of treated gliomas for the differential diagnosis between radiation necrosis and tumor recurrence.

  14. Evaluation of the influence of percent labeling of 99mTc-MIBI on nuclear medicine procedures in Recife, Pernambuco State, Brazil

    International Nuclear Information System (INIS)

    Pereira, Jucilene Maria

    2003-08-01

    The aim of this work was to evaluate the influence of percent labeling of the radiopharmaceutical 99m Tc-MIBI on the procedures adopted by the nuclear medicine clinics in Recife, Pernambuco State, Brazil, and their possible interference with image quality in myocardial perfusion examinations. This work was performed at two nuclear medicine services in Recife that use pharmaceuticals provided by two different manufacturers: Cardiolite, provided by Dupont and Cardiosyd, provided by SYDMA. The pH, percent labeling and stability of samples of 99m Tc-MIBI and the percent uptake in heart and liver of a number of patients were evaluated. The results showed that the pH values measured in all samples of both radiopharmaceuticals were within the limits recommended. In 48% of the Cardiolite samples, the percent labeling was less than 90%, which is the minimum recommended limit. On the other hand, 87,5% of the Cardiosyd samples measured values above 98%. Both radiopharmaceuticals had good labeling stability, even in samples with low percent labeling efficiencies. In spite of the higher percent labeling of Cardiosyd its heart uptake is similar to that observed with the Cardiolite, even when the percent labeling is lower than 90%. On the other hand, the image quality, according to physicians, evaluation was poorer for Cardiosyd images, due to high noise and poor sharpness. (author)

  15. Application of 99mTc-MIBI myocardial tomography imaging for the diagnosis of coronary heart disease

    International Nuclear Information System (INIS)

    Wu Kegui; Chen Daguang; Chen Jinshui

    1992-01-01

    99m Tc-MIBI myocardial tomography imaging was obtained from 119 cases with Sopha Medical SPECT system. 38 cases of coronary heart diseases, 33 cases of coronary heart diseases combined with hypertension and 48 cases of myocardial infarction were diagnosed according to clinical symptoms and signs, ECG, exercise ECG (treadmill test) and other laboratory studies. The results showed that positive rate of myocardial thermography imaging for detecting coronary heart disease was 70.21% at rest, and the positivity can be further increased by myocardial tomography imaging with exercise test. On the contrary the positivity of exercise ECG was only 63.8%. It was concluded that radionuclide myocardial tomography imaging was noninvasive and more sensitive and specific than the exercise ECG in detecting coronary heart disease

  16. Frequency and severity of myocardial perfusion abnormalities using Tc-99m MIBI SPECT in cardiac syndrome X

    International Nuclear Information System (INIS)

    Saghari, Mohsen; Assadi, Majid; Eftekhari, Mohammad; Yaghoubi, Mohammad; Fard-Esfahani, Armaghan; Malekzadeh, Jan-Mohammad; Sichani, Babak Fallhi; Beiki, Davood; Takavar, Abbas

    2006-01-01

    Cardiac syndrome X is defined by a typical angina pectoris with normal or near normal (stenosis <40%) coronary angiogram with or without electrocardiogram (ECG) change or atypical angina pectoris with normal or near normal coronary angiogram plus a positive none-invasive test (exercise tolerance test or myocardial perfusion scan) with or without ECG change. Studies with myocardial perfusion imaging on this syndrome have indicated some abnormal perfusion scan. We evaluated the role of myocardial perfusion imaging (MPI) and also the severity and extent of perfusion abnormality using Tc-99m MIBI Single Photon Emission Computed Tomography (SPECT) in these patients. The study group consisted of 36 patients with cardiac syndrome X. The semiquantitative perfusion analysis was performed using exercise Tc-99m MIBI SPECT. The MPI results were analyzed by the number, location and severity of perfusion defects. Abnormal perfusion defects were detected in 13 (36.10%) cases, while the remaining 23 (63.90%) had normal cardiac imaging. Five of 13 (38.4%) abnormal studies showed multiple perfusion defects. The defects were localized in the apex in 3, apical segments in 4, midventricular segments in 12 and basal segments in 6 cases. Fourteen (56%) of all abnormal segments revealed mild, 7(28%) moderate and 4 (16%) severe reduction of tracer uptake. No fixed defects were identified. The vessel territories were approximately the same in all subjects. The Exercise treadmill test (ETT) was positive in 25(69%) and negative in 11(30%) patients. There was no consistent pattern as related to the extent of MPI defects or exercise test results. Our study suggests that multiple perfusion abnormalities with different levels of severity are common in cardiac syndrome X, with more than 30 % of these patients having at least one abnormal perfusion segment. Our findings suggest that in these patients microvascular angina is probably more common than is generally believed

  17. Contrast-enhanced computed tomography does not improve the diagnostic value of parathyroid dual-phase MIBI SPECT/CT

    DEFF Research Database (Denmark)

    Andersen, Trine B; Aleksyniene, Ramune; Boldsen, Søren K

    2018-01-01

    OBJECTIVE: The aim of this study was to investigate the contribution of contrast-enhanced computed tomography (CE-CT) to the localization of parathyroid adenomas compared with the dual-phase Tc-99m MIBI SPECT with low-dose CT (LD-CT). PATIENTS AND METHODS: This retrospective study included...... consecutive patients with primary hyperparathyroidism who underwent a preoperative dual-phase MIBI SPECT/CT followed by surgical resection. The standard of care was dual-phase MIBI SPECT/CT, acquired with LD-CT in the early phase and CE-CT in the late phase (SPECT/CE-CT). The presence and localization...... of positive sites were extracted from study reports. To examine the role of CE-CT, patient cases were independently re-reviewed, with the early LD-CT fused with early and late SPECT (SPECT/LD-CT). The two SPECT/CT methods were compared for sensitivity, and the positive predictive value and histopathology were...

  18. The diagnosis accuracy and safety of 99Tcm-MIBI myocardial perfusion imaging-a retrospective multicenter study

    International Nuclear Information System (INIS)

    Wang Rongfu; Qiu Yanli; Wang Liqin

    2012-01-01

    Objective: To evaluate the diagnostic accuracy and safety of 99 Tc m -MIBI MPI by retrospectively analyzing data from this multicenter study. Methods: Participating centers included six hospitals: Peking University First Hospital, Beijing Fuwai Hospital of Chinese Academy of Medical Science and Peking Union Medical College, Anzhen Hospital of Capital Medical University, Beijing Hospital of Health Ministry, Beijing Tongren Hospital of Capital Medical University and Peking University People's Hospital. According to the inclusion and exclusion criteria, 500 subjects (335 male, 165 female, mean age (60.1 ±11.1) years) who underwent MPI between April 1998 and April 2006 were enrolled. All subjects were investigated with stress/rest MPI and CAG within 1 month. Stress test was performed with bicycle ergometry or with intravenous dipyridamole, adenosine or ATP. Perfusion defects on MPI were allocated to corresponding coronary arteries. During the stress and imaging period,any discomfort or symptoms were recorded. Coronary stenosis with ≥ 50% luminal narrowing was considered significant in CAG and taken as the gold standard. 99 Tc m -MIBI MPI results for the number of stenosed vessels, stenotic severity and coronary artery allocation were compared using χ 2 test. Results: There were 280 subjects that underwent exercise stress tests and the remaining 220 received pharmacological stress tests (117 adenosine, 32 dipyridamole, 71 ATP). Two hundred and forty-nine patients had significant coronary stenosis and 251 had normal CAG. Out of the 249 patients with positive CAG results, 101 had one-vessel, 66 had two-vessel and 82 had three-vessel disease. Significant stenosis of the LAD was present in 205 patients, 144 had RCA stenosis and 130 had stenosis of the LCX. The sensitivity,specificity, accuracy, positive predictive and negative predictive values of MPI for detection of coronary artery disease were 65.1% (162/249), 81.3% (204/251), 73.2% (366/500), 77.5% (162

  19. Measurement and Estimation of the 99Mo Production Yield by 100Mo(n,2n)99Mo

    Science.gov (United States)

    Minato, Futoshi; Tsukada, Kazuaki; Sato, Nozomi; Watanabe, Satoshi; Saeki, Hideya; Kawabata, Masako; Hashimoto, Shintaro; Nagai, Yasuki

    2017-11-01

    We, for the first time, measured the yield of 99Mo, the mother nuclide of 99mTc used in nuclear medicine diagnostic procedures, produced by the 100Mo(n,2n)99Mo reaction with accelerator neutrons. The neutrons with a continuous energy spectrum from the thermal energy up to about 40 MeV were provided by the C(d,n) reaction with 40 MeV deuteron beams. It was proved that the 99Mo yield agrees with that estimated by using the latest data on neutrons from the C(d,n) reaction and the evaluated cross section of the 100Mo(n,2n)99Mo reaction given in the Japanese Evaluated Nuclear Data Library. On the basis of the agreement, a systematic calculation was carried out to search for an optimum condition that enables us to produce as much 99Mo as possible with a good 99Mo/100Mo value from an economical point of view. The calculated 99Mo yield from a 150 g 100MoO3 sample indicated that about 30% of the demand for 99Mo in Japan can be met with a single accelerator capable of 40 MeV, 2 mA deuteron beams. Here, by referring to an existing 18F-fluorodeoxyglucose (FDG) distribution system we assumed that 99mTc radiopharmaceuticals formed after separating 99mTc from 99Mo can be delivered to hospitals from a radiopharmaceutical company within 6 h. The elution of 99mTc from 99Mo twice a day would meet about 50% of the demand for 99Mo.

  20. Technetium-99m-hexakis-2-methoxyisobutylisonitrile scintigraphy and multidrug resistance-related protein expression in human primary lung cancer

    International Nuclear Information System (INIS)

    Duan Xiaoyi; Wang Jiansheng; Liu Min; Guo Youmin

    2008-01-01

    The occurrence of multidrug resistance (MDR) is a major cause of resistance to chemotherapeutic agents in patients with lung cancer, in part owing to the overexpression of MDR-related proteins. Technetium-99m-hexakis-2-methoxyisobutylisonitrile ( 99m Tc-MIBI) has been shown to be a substrate for some MDR-related proteins. The aim of this study is to evaluate the role of 99m Tc-MIBI scintigraphy for functional imaging of MDR-related protein phenotypes. To determine the correlation between 99m Tc-MIBI scintigraphy and the expression level of P-glycoprotein (Pgp), multidrug-resistance protein (MRP), and glutathione-S-transferase Pi (GSTπ), 26 patients (17 men and 9 women, median age 57.5 years) with primary lung cancer were investigated. Following intravenous administration of 925 MBq 99m Tc-MIBI, single-photon emission computed tomography (SPECT) and computed tomography (CT) were performed at 15 min and 2 h. On the basis of the fused images, tumor to background (T/B) ratio of both early and delayed images, and washout rate (WR%) of 99m Tc-MIBI were calculated. The immunohistochemical staining of Pgp, MRP, and GSTπ was performed, and the expression level was semiquantitated using a pathoimage analysis system. The imaging results were compared with the status of Pgp, MRP, and GSTπ expression. The WR% of 99m Tc-MIBI showed a significant positive correlation with Pgp expression (r=0.560, P=0.003), as no correlation was observed between WR% and MRP or GSTπ (r=0.354, P=0.076; r=0.324, P=0.106). Neither early T/B nor delayed T/B correlated with the expression level of Pgp, MRP, and GSTπ. WR%, Pgp, and GSTπ expression showed significant differences between squamous cell carcinoma (group A) and adenocarcinoma (group B). There was no significant difference among Pgp, MRP, and GSTπ expression levels in any cases (P>0.05). Our data confirmed that 99m Tc-MIBI scintigraphy is useful for determining the MDR caused by Pgp in patients with primary lung cancer. (author)

  1. Re-estimation of renal function with 99mTc-DTPA by the Gates' method

    International Nuclear Information System (INIS)

    Itoh, Kazuo; Arakawa, Masanori

    1987-01-01

    We analyzed a regression equation between percent total renal uptake (%TRU) of 99m Tc-DTPA and creatinine clearance (Ccr) by the Gates' method in 82 patients. 1) The following regression equations between measured renal depth on CT scan and (weight in kg)/(height in cm) in Japanese were obtained; Right in both kidneys = 13.6361 · (W/H) 0.6996 (n = 217, r = 0.86691, p 0.7554 (n = 224, r = 0.8822, p 0.8099 (n = 27, r = 0.9515, p 0.6997 (n = 21, r = 0.9213, p 2 ) = 13.15 · %TRU 0.787 (n = 86, r = 0.820, p 0.753 (n = 40, r = 0.754). The Gates' method is very convenient for an immediate estimation of glomerular filtration rate (GFR) after renal scintigraphy using 99m Tc-DTPA. However, the correlation coefficient was not high as compared to the Gates' results. The equation which was reported by Gates' is not necessarily adaptable in routine study. Each facility which uses the Gates' method for estimating GFR should obtain the corrected regression equation between %TRU and Ccr. (author)

  2. Development of a kit for Tc-MIBI preparation

    International Nuclear Information System (INIS)

    Cruz, J.; Lopez, M.; Hernandez, I.; Chiotellis, E.

    1994-01-01

    The development and evaluation of formulation to obtain 99 mTc-MIBI were carried out. The work consisted of ligand synthesis, development of a suitable formulation, study of the product biological behaviour in laboratory animals and the lyophilized product stability. (L.C.J.A.). 5 refs, 1 fig, 5 tabs

  3. Comparative study of 99Mo/99mTc generators at base of synthesized gels starting from 99Mo of activation and of fission

    International Nuclear Information System (INIS)

    Lopez M, I.Z.; Monroy G, F.; Rivero G, T.; Rojas N, P.

    2007-01-01

    At the present time the more used and diffused radionuclide in nuclear medicine it is the Technetium 99 metastable ( 99 mTc) it is used for diagnostic and therapy. It is produced starting from molybdenum 99 ( 99 Mo), which is absorbed in chromatographic columns, loaded with alumina that absorb only 0.2% of 99 Mo situation that forces to use high specific activities of 99 Mo that it is obtained starting from the fission of the 235 U. Given these conditions and limitations, new preparation procedures of 99 Mo/ 99m Tc generators, of low or medium specific activity, its have been developed, using gels of zirconium molybdates that incorporates until 30% in weight of 99 Mo in the gel, and also conserve similar characteristics of quality and purity that those obtained by the traditional generator; reducing by this way the cost of production of the 99m Tc, when using 99 Mo of low specific activity, in the preparation of 99 Mo/ 99m Tc generators. The radiochemical characteristics of the elution of 99m Tc, depends strongly on the gel preparation conditions. In particular, the present work has for object to determine the influence of the used type of 99 Mo, fission or activation product, during the gels synthesis, as well as the used air flow for the agitation in the gels preparation and its influence in the quality of the 99 Mo/ 99m Tc generators. When diminishing the agitation air flow the efficiency it increases and in the radionuclide purity of the eluates and when using 99 Mo of fission for the gels production it increases in an important way the elution efficiency, the radiochemical purity and radionuclide of the eluates of 99m Tc. (Author)

  4. The role of technetium-99m methoxyisobutylisonitrile scintigraphy in the differential diagnosis of cold thyroid nodules

    Energy Technology Data Exchange (ETDEWEB)

    Mezosi, E.; Bajnok, L.; Sztojka, I.; Szabo, J.; Leovey, A.; Kakuk, G.; Nagy, E. [Department of Medicine, University Medical School, Debrecen (Hungary); Gyory, F. [Department of Surgery, University Medical School, Debrecen (Hungary); Varga, J.; Galuska, L. [Nuclear Medicine Centre, University Medical School, Debrecen (Hungary)

    1999-08-01

    Various diagnostic techniques have been successfully used in the clinical management of cold nodules; however, the decision on whether to employ surgery or a conservative treatment is not always easy. This study was designed to appraise the diagnostic value of technetium-99m methoxyisobutylisonitrile (MIBI) scintigraphy in the assessment of cold nodules detected using {sup 99m}Tc-pertechnetate. Fifty-two patients were included in the study. All had already been selected for surgery, based on their clinical and laboratory findings, including fine-needle aspiration biopsy. The total number of cold nodules on {sup 99m}Tc-pertechnetate scans was 59. The thyroid scan was performed 20-40 min after i.v. injection of 400 MBq of {sup 99m}Tc-MIBI. Uptake of MIBI in thyroid nodules was compared with that in the surrounding normal thyroid tissue, and a score of between 0 and 3 was assigned to each nodule as follows: 0, cold; 1, decreased; 2, equal; 3, hot. Definitive histology revealed nodular goitre in 24 cases, adenoma in 19, thyroiditis in 1, differentiated cancer in 12, medullary cancer in 2, and anaplastic cancer in 1. None of the degenerative nodules were hot on MIBI scan, while the adenomas showed a variety of MIBI imaging patterns, most frequently the score 3 pattern. In the diagnosis of differentiated thyroid cancer the sensitivities of score 3 and score 2+3 MIBI uptake patterns were 83% (10/12) and 100%, respectively. The score 3 MIBI uptake pattern had a specificity of 100% and a positive predictive value of 100% with respect to thyroid (benign and malignant) neoplastic diseases, whereas a specificity of 72% and a positive predictive value of 43% were observed in the detection of differentiated cancer. After a cold nodule had been detected using {sup 99m}Tc-pertechnetate, a second scan with high MIBI uptake increased by 7.8 times the probability that this nodule would be a differentiated cancer. In conclusion, {sup 99m}Tc-MIBI scintigraphy is a useful method in the

  5. The preparation of {sup 99m}Tc from {sup 99}Mo-{sup 99m}Tc using Poly-Zirconium Compound (PZC)

    Energy Technology Data Exchange (ETDEWEB)

    Laohawilai, S [Isotope Production Div., Office of Atomic Energy for Peace (Thailand)

    1998-10-01

    The process of for providing the {sup 99m}Tc-gel generator followed the protocol that received from Department of Radioisotopes, Tokai Research Establishment, JAERI. Sodium molybdate (molybdenum-99), pH 7 with concentration 20 mg/ml and activity nearly 1 mCi/ml was added into the adsorbent (PZC). The total activity of {sup 99}Mo was about 10 mCi and the heating time was varied from 3-18 hours at 70degC. The properties of the gel were studied for elution profile and elution efficiency. The molybdenum breakthrough in sodium pertechnetate (technetium-99m) was also performed. (author)

  6. Assessment of left ventricular performance by ECG-gated SPECT. Comparison with magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Tadamura, Eiji; Inubushi, Masayuki; Kubo, Shigeto; Matsumoto, Keiichi; Yokoyama, Hiroshi; Fujita, Toru; Konishi, Junji [Kyoto Univ. (Japan). Faculty of Medicine

    1999-10-01

    In the measurement of a left ventricular volume, MIBI-QGS was compared with MRI. Because it became clear by the experiment using phantom that a volume calculated with QGS was smaller than the actual volume, data of clinical study were corrected. Subjects were 20 patients with coronary artery disease. Fourteen patients had anamnesis of myocardial infarct. ECG-gated SPECT was performed one hour after intravenous injection of MIBI (600 MBq) in rest. End diastolic volume (EDV), end systolic volume (ESV) and ejection fraction (EF) were calculated using QGS. Cine-MR image was obtained by using MR system of 1.5 Tesla within 1 week after SPECT. A condition was as follows; segmented k-space gradient echo with view sharing, TR=11 ms, TE=1.4 ms, flip angle 20 degree, field of view 32 cm, matrix 256 x 196, 8 lines per segment. LVEF, ESV and EF were analysed by Bland-Altman method, and the difference between MIBI-gated-SPECT and MRI was no problem. Horizontal dislocation image and vertical major axis dislocation image were provided. Minor axis crossing images of 10-12 slice were also filmed in order to cover all left ventricles. As a result, availability of MIBI-QGS became clear. Some factors which produces the measurement error are examined. (K.H.)

  7. Scintigraphic findings on 99mTc-MDP, 99mTc-sestamibi and 99mTc-HMPAO images in Gaucher's disease

    International Nuclear Information System (INIS)

    Mariani, G.; Molea, N.; La Civita, L.; Porciello, G.; Lazzeri, E.; Ferri, C.

    1996-01-01

    We report here on the use of the lipophilic cationic complex technetium-99m sestamibi ( 99m Tc-MIBI), employed as an indicator of increased cellular density and metabolic activity, to evaluate Gaucher cell infiltrates in the bone marrow; 99m Tc-hexametazime ( 99m Tc-HMPAO) was also employed, as a pure indicator of lipidic infiltration in the bone marrow. A 67-year-old patient with known type 1 Gaucher's disease presented with a painful left hip and knee and difficulty in gait subsequent to traumatic fracture of the left femoral neck that had required implant of a fixation screw-plaque. Bone scan with 99m Tc-methylene diphosphonate revealed reduced uptake at the distal metaphyseal-epiphyseal femoral region. In addition, whole-body maps and spot-view acquisitions of the thighs and legs were recorded at both 30 min and 2.5 h after the injection of 99m Tc-MIBI: the scintigraphic pattern clearly showed increased uptake at several sites involved by Gaucher deposits in the bone marrow (both knees, with variable intensity in different areas), matching the bone changes detected by conventional x-ray. The target to non-target ratios slowly decreased with time, from an average value of 2.25 in the early scan to an average value of 2 in the delayed scan. The lipid-soluble agent 99m Tc-HMPAO exhibited a superimposable scintigraphic pattern of accumulation at the involved sites, though with lower target to non-target ratios (1.27-1.48). The results obtained in this patient suggest a potential role of 99m Tc-MIBI in the scintigraphic evaluation of Gaucher's lipid deposits in the bone marrow. If the results are confirmed in other patients, this radiopharmaceutical would offer clear advantages over 133 Xe because of its wider availability and greater practicality (i.v. administration of 99m Tc-MIBI versus inhalation of 133 Xe, and use of a single gamma camera instead of two as with 133 Xe). (orig.). With 3 figs

  8. A modified {sup 99} Mo- {sup 99} Tc generator on Zirconium molybdo- phosphate-{sup 99} Mo gel. Vol. 3

    Energy Technology Data Exchange (ETDEWEB)

    El-Kolaly, M T; Talaat, H [Labelled Compounds Department, Cairo (Egypt); Botros, N [Radioistspe and Generator Department, Radioisotope Production and Sealed Source Division, Hot Laboratories Center, Atomic Energy Authority, Cairo (Egypt)

    1996-03-01

    A modified {sup 99} Mo - {sup 99} Tc gel generator is described. The new generator is based on the use of zirconium molybdophosphate - {sup 99} Mo gel in which {sup 99} Mo chemically combined in the gel structure, where {sup 99m}Tc can be easily eluted with distilled water or saline. The gel was prepared via chemical reaction between zirconyl chloride and molybdophosphate - {sup 99} Mo solution. The PH of the reaction mixture was adjusted with NaOH. Different gels have been prepared by varying the molar ratio of Mo:Zr:p. The PH and time of digeston on complete gel formation was also investigated in order to optimize the condition of gel preparation. Molybdophosphate {sup 32} P solution was used to determine the phosphorous content in the gel and in the {sup 99m}Tc eluate. The temperature and time of drying of the gel and their effect on {sup 99m}Tc elution efficiency were also studied. From the data obtained, the optimum conditions for routine production of {sup 99} Mo - {sup 99m}Tc generator are presented and discussed. 2 figs., 6 tabs.

  9. Diagnosis of severe and extensive coronary artery disease using gated myocardial perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Ihn Ho; Lee, Hyoung Woo; Won, Kyu Chang; Park, Jong Sun; Sin, Dog Gu; Kim, Young Jo; Shim, Bong Sub [College of Medicine, Yeungnam Univ., Taegu (Korea, Republic of)

    1999-07-01

    Left ventricular volumes and ejection fractions constitute important informations in the diagnosis and prognosis of cardiac disease. Aim of the study is to verify if the assessment of left ventricular function and perfusion together by gated myocardial perfusion SPECT is useful for diagnosing severe and extensive CAD. We examined 27 consecutive patients (17 males and 10 females, mean age : 60.1 years) who underwent two day rest/stress Tc-99m MIBI gated SPECT. Stress was done with adenosine. Post-stress gated SPECT was done at 1 hour after an injection of Tc-99m MIBI (740 MBq). All patients underwent coronary angiography after gated SPECT within 1 month. We divided them three groups with single vessel disease, double vessel disease and triple vessel disease or severe proximal left coronary artery stenosis. Extent of Defect (ED), Reversibility of Extent (RE), Severity of Defect (SD) and Severity of Reversibility (SR) were calculated by CEqual program. Post-stress LVEF, Rest LVEF, End-diastolic volume(EDV), End-systolic volume(ESV), Transient Ischemic Dilation (TID) of left ventricle (Post-stress EDV/Rest EDV) were calculated using gated SPECT quantification program. Left ventricle is divided with 18 segments and wall motion was scored (normal=0, mild hypokinesia =1, severe hypokinesia =2, akinesia =3 and dyskinesia =4), and then post-stress summed wall motion score was calculated. Post-stress summed wall motion score and post-stress LVEF were significant differences between three groups ( P <0.01). Extent of defect, Extent of reversibility, Severity of defect and severity of reversibility in Polar map were significant differences between three groups ( P <0.01). Post-stress Transient left ventricular dilatation and test LVEF were not significant differences between three groups ( P > 0.05). The gated SPECT pattern (low post-stress LVEF and post-stress summed wall motion score) add important diagnostic information over ungated perfusion data (high ED, ER and SR and

  10. Analysis of the variation of the activity of a "9"9"mTc sample after dilution with saline solution

    International Nuclear Information System (INIS)

    Kuahara, L.T.; Correa, E.L.; Potiens, M.P.A.

    2016-01-01

    The activity meter is essential equipment in nuclear medicine services.To ensure its good operation and know the factors which may influence its readings is vital for the activity administered to the patient be correct. Many factors may influence the activity meter accuracy, such as the type of container, geometry, and radioactive material volume. The aim of this study was to analyze the measurements variations in 0.5 ml and 1.0 ml of "9"9"mTc pure and diluted in 2.5 ml of saline solution, in containers used in nuclear medicine. Variations of up to 4 % in measured values were found. (author)

  11. Studies of post-elution concentration of {sup 99m}-Tc eluted from a gel type chromatographic generator

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Katia N.; Osso Junior, Joao Alberto [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mail: norisuzuki6@yahoo.com.br; jaosso@ipen.br

    2007-07-01

    The radiopharmaceuticals most used in Diagnostic Nuclear Medicine are those labeled with the metastable technetium ({sup 99m}Tc) due to its ideal physical properties of decay (t{sub 1/2} 6.01 h, E{gamma} 140 keV), low cost and availability facilitated through the commercial generator {sup 99}Mo /{sup 99m}Tc. This radionuclide is formed by the {beta}{sup -} decay of {sup 99}Mo adsorbed on an alumina column of the generator and collected in the form of sodium pertechnetate (Na{sup 99m}TcO{sub 4}) by elution with saline solution (0.9%). The Radiopharmacy Center (CR) of the IPEN-CNEN/SP developed a gel type chromatographic generator of MoZr with {sup 99}Mo produced by {sup 98}Mo(n, {gamma}){sup 99}Mo reaction that occurs in IEA-R1 Nuclear Reactor. The gel is composed of zirconium molybdate with elution volume of 12 ml with an activity of 11100 MBq (300 mCi) producing a radioactive concentration of 925 MBq (34 mCi) / ml. The fission generator gives a higher radioactive concentration around 1850 MBq (69 mCi) / ml. The aim of this work is to study a system of post-elution concentration using ion exchange cartridges in tandem (cation - anion) for the attainment of a high enough radioactive concentration to meet the demand of market, with a proved quality. This system of concentration will be made based in the technique of solid phase extraction (SPE) using commercial cartridges of extraction, which contains the solid phase and eluent saline solution (0.9%). As the eluent results of this system used in the gel generator of MoZr will be compared with the fission generator currently produced by IPEN-CNEN/SP. (author)

  12. Dosimetric contribution of organs of biokinetics of {sup 99m}Tc and {sup 123}I to estimate radiation doses in thyroids of children of 1 and 5 years; Contribucion dosimetrica de organos de la biocinetica del {sup 99m}Tc y {sup 123}I para estimar dosis en tiroides de ninos de 1 y 5 anos

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez, M.V.; Castillo, C.E.; Abanto, D.M.; Rocha, D.; Garcia, W.H.; Marin, K., E-mail: marvva@hotmail.com [Universidad Nacional de Trujillo (UNT), Trujillo (Peru); Quispe, R. [Centro de Ciencias Aplicadas y Desarrollo Tecnologico, UNAM, Mexico (Mexico)

    2015-07-01

    The absorbed doses by thyroids during uptake studies through biokinetics of radiopharmaceuticals containing {sup 123}I (iodine) or {sup 99m}Tc (pertechnetate) are estimated. Using the MIRD scheme and the representation of Cristy-Eckerman for thyroids in children of 1 and 5 years, the objective of the study was to determine whether the dosimetric biokinetic contributions of the organs of {sup 123}I (iodide) and {sup 99m}Tc (pertechnetate) biokinetic are significant in the estimated of the absorbed dose for thyroid uptake studies.

  13. Brain Tumour Scintigraphy with {sup 99m}Tc-Pertechnetate, {sup 99m}Tc-Fe(II) Complex and {sup 131}I-Labelled Macroaggregated Albumin - Comparison of Results; La Scintigraphie des Tumeurs Cerebrales a l'Aide de Pertechnetate Marque au {sup 99m}Tc, de Complexe {sup 99m}Tc-Fe-II et de Macroagregats d'Albumine Marques au {sup 131}I. Comparaison des Resultats

    Energy Technology Data Exchange (ETDEWEB)

    Haas, J. P.; Dietz, H.; Schmidt, K. J.; Doerr, F.; Brod, K. H.; Wolf, R. [Institut de Radiologie Clinique et Clinique de Neurochirurgie, Universite de Mayence, Federal Republic of Germany (Germany)

    1969-05-15

    {sup 99m}Tc, in the form of pertechnetate, has now gained its place in brain scintigraphy. The present authors and many others have found its diagnostic value equal to that of substances labelled with mercury or iodine. Using {sup 99m}Tc-pertechnetate as the basis of their work, the authors attempted to extend isotopic diagnosis by two methods, namely: intra-arterial introduction of macroaggregated albumin; and intravenous injection of a new substance, the {sup 99m}Tc-Fe(II) complex. Following their publication in 1966 of the results obtained with the first method, the authors now present an account of their experiments carried out on over 100 patients with brain tumours. Compared with scintigraphy involving intravenous injection of {sup 99m}Tc-pertechnetate, this new method gives supplementary information which is often of considerable help in clinical neuroradiological diagnosis of these patients. The findings in a majority of cases were confirmed by operation or by autopsy. The method made it possible for the first time to use scintigraphy to visualize the arterial network of the brain. In view of the ease with which brain scintigraphy can be performed after intravenous injection, and also of our experience with the {sup 99m}Tc-Fe(II) complex in kidney scintigraphy and the evidence of a brief report in the United States literature, the authors decided to try out this substance in the detection of brain tumours. Their first results showed it to be incontestably superior to all others previously applied intravenously. It has the indubitable advantages of {sup 99m}Tc as regards the irradiation dose to the patient and gives an exceptionally precise delineation of the invasive cerebral processes due to a rapid fall in blood concentration. A combination of these two new scintigraphic methods would thus seem to open up new possibilities and greatly enhance the field of application of radioisotopes in the clinical study of brain diseases. The paper contains material

  14. Differential diagnosis of MRI detected intra cranial space occupying lesions (ICSOLS)-role of 99MTC tetrofosmin cerebral spect

    International Nuclear Information System (INIS)

    Padmal, S.; Sundaram, P.S.; Kumar, S.

    2004-01-01

    Discriminating the correct etiology of Intra Cranial Space Occupying Lesions (ICSOLs) detected by MRI is of paramount importance in deciding the right therapeutic approach. Functional imaging like 99m Tc Tetrofosmin cerebral SPECT (C SPECT) can be used to differentiate malignant from other benign cerebral pathologies. Objective: Our aim was to assess the efficacy of C SPECT in differentiating various etiologies (i.e. Infective / Inflammatory, Neoplastic and Post Radiotherapy changes) of MRI detected ICSOLs. We also aimed to assess the incremental value of quantitative uptake ratios in identifying the exact nature of ICSOLs. Method: 26 Patients (M:F=20:6), age range 28-76 yrs, mean 42±7 yrs were evaluated by 99mTc Tetrofosmin cerebral SPECT. 14/26 patients were HIV positive cases while remaining 12 were treated patients of intracerebral malignancies. All these patients had one or more discrete MRI detected ICSOLs. 6/4 patients with HIV and 4/12 patients in the non HIV group showed more than 1 discrete ICSOLs. 20 mci of 99mTc Tetrofosmin was injected IV .15 min (early) and 2 hrs (delayed) post injection C SPECT images were acquired on a dual head variable angle Gamma camera. After reconstruction, transverse, coronal and sagittal images were co- registered with DICOM online available MRI images using aco- registration software. Focal Tetrofosmin uptake in MRI detected ICSOL was interpreted as abnormal. Tetrofosmin uptake index (Ix) was calculated in early and delayed images as ratio of counts in lesion to that of contra lateral region. A value of more than 1.3 was considered to be abnormal. Persistent Ix of more than 1.3 in initial and delayed images were considered to be malignant while Ix of more or less than 1.3 in initial but less than 1.3 in delayed images was considered to be benign in both groups. Results: In HIV group (14 pts), 4 patients showed an Ix of less than 1.3 in both early and delayed images and 7 patients showed an Ix of more than 1.3 in early but

  15. The method of activity determination of Tc-99m in ionization chamber

    International Nuclear Information System (INIS)

    Broda, R.

    1980-01-01

    The paper presents a method of finding the efficiency of sup(99m)Tc activity measurements in the ionization chamber, basing on 99 Mo activity measurements and the activity ratio of sup(99m)Tc to 99 Mo in 99 Mo + sup(99m)Tc solution. The activity of 99 Mo has been determined in 4πβ-γ coincidence system with liquid scintillator in β channel by means of the absolute method of two-stage coincidence. The activity ratio of sup(99m)Tc to 99 Mo has been determined by means of spectrometric method. The 99 Mo and sup(99m)Tc activities have been measured in 99 Mo + sup(99m)Tc generators, and the activity of sup(99m)Tc solution after elution has been measured. It has been shown that sup(99m)Tc activity, determined by means of the chamber method on the basis of the efficiency found, corresponds to the activity determined by means of spectrometric method, and that sup(99m)Tc activity, measured in generator before elution, is equal to the sum of sup(99m)Tc activity eluted and the one remained in generator. (author)

  16. Labelling and optimization of PHOTOFRIN {sup registered} with {sup 99m}Tc

    Energy Technology Data Exchange (ETDEWEB)

    Fakhar-e-Alam, M. [Pakistan Institute of Engineering and Applied Sciences, Islamabad (Pakistan); Roohi, S.; Amir, N.; Zahoor, R. [Pakistan Institute of Nuclear Science and Technology, Islamabad (Pakistan). Isotope Production Div.; Atif, M.; Firdous, S. [National Institute of Laser and Optronics, Islamabad (Pakistan). Biophotonics Lab.

    2010-07-01

    PHOTOFRIN {sup registered} was labelled with {sup 99m}Tc using SnCl{sub 2}.2H{sub 2}O as reducing agent. Instant thin layer chromatography (ITLC-SG) in 0.05 M NaOH was used for evaluation of radiochemical purity. Labelling efficiency was dependent on various factors that include the ligand/reductant ratio, pH and time of incubation. Therefore, optimum conditions of labelling were also determined. The stability of {sup 99m}Tc-PHOTOFRIN {sup registered} in serum was checked by using fresh human serum. Tissue distribution of {sup 99m}Tc-PHOTOFRIN {sup registered} was evaluated in Sprague Dawley rats. PHOTOFRIN {sup registered} was labelled with an efficiency of > 95% under optimum conditions, which were PHOTOFRIN {sup registered}: 200 {mu}g, pH: 3-4, SnCl{sub 2}.2H{sub 2}O: 15 {mu}g and 30 min incubation at room temperature. The {sup 99m}Tc-labelled PHOTOFRIN {sup registered} remained stable in human serum for 24 h. Biodistribution study in rats revealed maximum concentration of the labelled compound in liver, lungs and spleen at 0.5 h, and significant activity was also seen in the bladder and urine, indicating the mode of urinary excretion of PHOTOFRIN {sup registered}. (orig.)

  17. The utility of the gammagraph with 99mTc-MIBI as a complement to mammography in patients with a suspicion of breast cancer in a Havanna, Cuba health area

    International Nuclear Information System (INIS)

    Pena Quian, Yamile; Pena Coego, Andria; Coca Perez, Marco A; Batista Cuellar, Juan F

    2006-01-01

    To determine the utility of the gammagraphy with 99m Tc-MIBI, like complement of the mammography, in the study of patient with breast cancer suspicion, we study 22 patients with nodules of breast, in an area of health, by means of ultrasound, mammography, gammagraphy and biopsy, this it constituted the gold standard. The 68.2% of the patients presented carcinomas of breast and 31.8% injures benign. The gammagraphy showed values of sensibility, specificity and accuracy diagnoses superiors to the remaining techniques employees. Metastasis in axillary's nodule existed in 46.6% of the cases with breast cancer. Four (57.1%) they were detected by the gammagraphy. Conclusions: The gammagraphy with 99m Tc-MIBI was of great utility like complement of the mammography, for the study of patient with breast cancer, it was specially useful in the cases reported as suspects and uncertain for the mammography and in the detection of axillaries nodules (au)

  18. Distribuição do dextran-99mTc e do carvão ativado no linfonodo-sentinela em coelho = Distribution of dextran-99mTc and activated carbon in sentinel lymph nodes of rabbits

    Directory of Open Access Journals (Sweden)

    Rocha, Rogério Porto da

    2006-01-01

    Conclusões: A solução de CA (6% e corante vital (azul patente V na proporção 1: 1 determinou uma fácil identificação do LS no intra-operatório. A análise comparativa da distribuição do CA e do dextran-99mTc demonstra que ambos se comportaram da mesma forma concentrando-se na mesma metade do LS

  19. Comparison of thallium-201 scan and Tc-99m sestamibi scan in the differential diagnosis of breast mass

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Ihn Ho; Won, Kyu Jang; Lee, Hyung Woo; Lee, Soon Jung [College of Medicine, Yonsei Univ., Seoul (Korea, Republic of)

    1999-02-01

    We performed this study to compare Tl-201 and Tc-99m MIBI scans for the differentiation of malignant from benign breast mass. Thirty-eight female patients underwent Tl-201 breast scan and thirty-two of them also underwent Tc-99m MIBI scan of the breast. After intravenous injection of 74-111 MBq of Tl-201, early (10 minutes) and delayed (3 hours) images were obtained. Then, 555-740 MBq of Tc-99m MIBI was injected and images after 30 minutes were obtained. We compared Tl-201 and Tc-99m MIBI scans with pathologic results. Twenty-three patients were confirmed to have infiltrating duct carcinoma and fifteen patients to have benign breast mass by excisonal biopsy. The sensitivity of early and delayed Tl-201 scan and Tc-99m MIBI scan in the detection of malignant breast lesion were 100% (23/23), 82% (18/22), and 90% (18/20), respectively. The sensitivity of early Tl-201 scan was significantly higher than that of delayed Tl-201 scan, (p<0.05). The specificity of early and delayed Tl-201 scan and Tc-99m MIBI scan were 73% (11/15), 73% (11/15) and 83% (10/12), respectively (p: not significant). Three patients out of nine with fibroadenoma and one patient with atypical duct hyperplasia were false positive in both early and delayed Tl-201 scans. The size of fibroadenoma with false positive in early and delayed Tl-201 scan (4 cases) was larger than that of 11 fibroadenoma with true negative scan (p<0.01). Metastatic axillary lymph node involvement was present in fifteen patients. The sensitivity to detect metastatic nodes was 38% (5/13) for early Tl-201 images, 15% (2/13) for delayed Tl-201 images, 58% (7/12) for Tc-99m MIBI planar images and 67% (4/6) for Tc-99m MIBI SPECT. The sensitivity of Tc-99m MIBI planar or SPECT was significantly higher than that of delayed Tl-201 images (p<0.05). Early Tl-201 and Tc-99m MIBI scan are useful noninvasive methods to differentiate malignant from benign mass of breast. Tc-99m MIBI scan was sensitive in detecting axillary lymph node

  20. Quality assurance of Mo-99/Tc-99m radionuclide generators

    Science.gov (United States)

    Uzunov, Nikolay; Yordanova, Galina; Salim, Seniha; Stancheva, Natalya; Mineva, Vanya; Meléndez-Alafort, Laura; Rosato, Antonio

    2018-03-01

    Gamma-ray spectrometry analyses of the radionuclide content of eluate from two Mo-99/Tc-99m radionuclide generators POLTECHNET have been performed. The relative activities of 99Mo 103Ru and 131I radioisotopes with respect to the activity of 99mTc at different time intervals after the primary pertechnetate elution of the generators have been analyzed. The relative activities of the isotopes were determined and compared to the radionuclidic purity requirements for 99mTc.

  1. Evaluation of '99Mo presence in eluates of 99mTc used in nuclear medicine

    International Nuclear Information System (INIS)

    Ribeiro, Bianca da Silva

    2010-01-01

    Tc-99m is used for diagnostic imaging in nuclear medicine through SPECT technique. It is obtained by the elution of 99 Mo/ 99m Tc generators. During the elution process 99 Mo can be extracted becoming a radionuclidic impurity. One of the quality parameters of the eluate is the radionuclidic purity, MBT (molybdenum break through), defined as the ratio between 99 Mo and 99m Tc activities in the eluate. The North-American and European pharmacopoeias restrict the 99 Mo content, respectively, in 0.015 e 0.1% and, according to the International Atomic Energy Agency (IAEA), the activity ratio at the moment of administration of the radiopharmaceutical to the patient, should not exceed 0.015%. In Brazil, the control of such parameter is not obliged in official regulations. Thus, the objective of this work is to evaluate the occurrence of 99 Mo in 99m Tc eluates. It was initially optimized a methodology to determine the activity of 99 Mo in eluate samples. Efficiency curves were obtained for a NaI (Tl) 8'' x 4'' scintillation detector installed at the In Vivo Monitoring Laboratory (LABMIV-IRD). The methodology has been validated through the measurement of a 99 Mo standard liquid source calibrated at the National Metrology Laboratory for Ionizing Radiation (LNMRI-IRD). The samples analyzed in this work were gently supplied by 5 Nuclear Medicine Clinics located in the city of Rio de Janeiro. The activities of 99 mTc and 99 Mo in those samples have been measured respectively at the clinics and at the LABMIV. By applying a standardized methodology, the ration between the activities were calculated. The results show that 147 out of 174 samples presented 99 Mo activities above the minimum detectable activity of the technique. On the other hand, only 2 out of 147 samples surpassed the MBT limit suggested by the IAEA and have been detected in samples eluted from generators of 750 mCi. In one of the samples, eluted from a generator of 1000 mCi, the calculated MBT value was very close

  2. Cintilografia do miocárdio com tecnécio 99m-MIBI e administração de adenosina em portadores de doença arterial coronária: correlação dos resultados com a angiografia coronária e o ultra-som intracoronário Adenosine myocardial perfusion SPECT with Tc-99m-MIBI in patients with obstructive coronary artery disease: correlation between quantitative coronary angiography and intravascular ultrasound measurements

    Directory of Open Access Journals (Sweden)

    Luiz Eduardo Mastrocolla

    2006-01-01

    Full Text Available OBJETIVO: Estabelecer a correlação da cintilografia de perfusão do miocárdio (CPM com Tecnécio 99m-MIBI (MIBI e injeção de adenosina, empregando a angiografia coronária quantitativa (ACQ e o ultra-som intracoronário (UIC como comparação. MÉTODOS: Estudo de 70 pacientes com doença arterial coronária (DAC, encaminhados à CPM com MIBI e adenosina. As manifestações clínicas, do eletrocardiograma (ECG e os resultados das imagens foram correlacionadas às variáveis da análise visual e quantitativa da angiografia, bem como ao UIC. RESULTADOS: A média de idades foi de 60,6 anos, com 39 pacientes do sexo masculino. A angiografia coronária evidenciou estenose do diâmetro da luz (E% de 49,94% em 105 artérias, com reavaliação à ACQ em 83 artérias (79% e média de 44,20%, pOBJECTIVE: To correlate myocardial perfusion scintigraphy (MPS with Tc-99m-MIBI and adenosine infusion using quantitative coronary angiography (QCA and intravascular ultrasound (IVUS. METHODS: Seventy patients with coronary artery disease (CAD referred for myocardial perfusion scintigraphy (MPS with MIBI and adenosine were studied. Clinical, electrocardiographic (ECG, and scintigraphic findings were correlated with variables of visual and quantitative angiographic analysis, as well as to those of IVUS. RESULTS: The mean age of patients was 60.6 years, and 39 were male. Coronary angiography showed percentage of diameter stenosis (% DS of 49.94% in 105 arteries, 83 of which were re-evaluated by QCA (79%, mean of 44.20%, p<0.05. ST-segment depression during adenosine infusion was associated with higher degrees of % DS (55.0% vs. 47.8%, p<0.05. Scintigraphic ischemia was correlated with greater cross-sectional area of lumen obstruction by IVUS (% CSA. Clinical, ECG, and IVUS findings were considered together and expressed as global ischemic versus non-ischemic responses. Ischemia was associated with lower values of minimal lumen diameter (MLD and minimal lumen area

  3. Comparison of different modalities in diagnosis of coronary artery disease (ECG, ETT, Angiography, Rest and Stress Echo. and 99m Tc-MIBI)

    International Nuclear Information System (INIS)

    Zein, A.A.M.

    2002-01-01

    This study was conducted in order to compare the most important five investigation modalities commonly used to investigate coronary artery disease, these were ECG, Exercise Tolerance Test (ETT), Echocardiography, SPECT imaging using 99m Tc-Sestamibi, and Angiography. The three test modalities, ECG, Echo, and 99m Tc-MIBI were conducted in both rest and stress conditions. All patients were referred to the hospital (NORI) from cardiology departments of different hospitals for stress/rest 99mTc-MIBI cardiac perfusion study. The decision to proceed with coronary angiography was made by the cardiologist to confirm or exclude diagnosis of CAD, to determine the potential surgical candidates and to assess complications if any. 17 patients were included in the study, 16 males and one female. All of them underwent the five test modalities mentioned, 80% of them were smokers, 47% were hypertensives, 20% were diabetics. The sensitivity of ECG, ETT, and Echocardiography were found to be 60.0%, 73.3%, and 82.4% respectively. Both angiography and 99mTc-Sestamibi were found to be 100% sensitive for detection of CAD. Specificity for all modalities tested was found to be 1, which is unrealistically high due to the small number of normal patients (only two). The predictive value of positive test came to be 1 for all test modalities, where as the predictive value of negative test was calculated to be 0.25, 0.33, and 0.67 for the tests, ECG, ETT, and Echocardiography respectively, but in case of 99mTc-Sestamibi, and coronary angiography it was found to be 1 for both of them. The localization ability of the different test modalities for ischemic and/or infarcted areas was investigated taking coronary angiography as the gold standard. All the three modalities, ECG, Echo, and 99mTc-Sestamibi showed good results in detection of areas supplied by left anterior descending artery, and on the other hand poor results in detection of left circumflex hypoperfused tributaries. The differential

  4. A preliminary feasibility study of simultaneous dual-isotope imaging with a solid-state dedicated cardiac camera for evaluating myocardial perfusion and fatty acid metabolism.

    Science.gov (United States)

    Ko, Toshiyuki; Utanohara, Yuko; Suzuki, Yasuhiro; Kurihara, Makiko; Iguchi, Nobuo; Umemura, Jun; Sumiyoshi, Tetsuya; Tomoike, Hitonobu

    2016-01-01

    Simultaneous dual-isotope SPECT imaging with 201Tl and (123)I-β-methyl-p-iodophenylpentadecanoic acid (BMIPP) is used to study the perfusion-metabolism mismatch. It predicts post-ischemic functional recovery by detecting stunned myocardium. On the other hand, (99m)Tc-MIBI is another radioisotope widely used in myocardial perfusion imaging because of its better image quality and lower radiation exposure than 201Tl. However, since the photopeak energies of (99m)Tc and (123)I are very similar, crosstalk hampers the simultaneous use of these two radioisotopes. To overcome this problem, we conducted simultaneous dual-isotope imaging study using the D-SPECT scanner (Spectrum-Dynamics, Israel) which has a novel detector design and excellent energy resolution. We first conducted a basic experiment using cardiac phantom to simulate the condition of normal perfusion and impaired fatty acid metabolism. Subsequently, we prospectively recruited 30 consecutive patients who underwent successful percutaneous coronary intervention for acute myocardial infarction, and performed (99m)Tc-MIBI/(123)I-BMIPP dual-isotope imaging within 5 days after reperfusion. Images were interpreted by two experienced cardiovascular radiologists to identify the infarcted and stunned areas based on the coronary artery territories. As a result, cardiac phantom experiment revealed no significant crosstalk between (99m)Tc and (123)I. In the subsequent clinical study, (99m)Tc-MIBI/(123)I-BMIPP dual-isotope imaging in all participant yielded excellent image quality and detected infarcted and stunned areas correctly when compared with coronary angiographic findings. Furthermore, we were able to reduce radiation exposure to significantly approximately one-eighth. In conclusion, we successfully demonstrated the practical application of simultaneous assessment of myocardial perfusion and fatty acid metabolism by (99m)Tc-MIBI and (123)I-BMIPP using a D-SPECT cardiac scanner. Compared with conventional (201)Tl

  5. Measurement and comparison of left ventricular ejection fraction utilizing first transit and gated scintiangiography

    International Nuclear Information System (INIS)

    Fletcher, J.W.; Herbig, F.K.; Daly, J.L.; Walter, K.E.

    1975-01-01

    Paired serial radionuclide scans were used for determinations of left ventricular ejection fraction (LVEF) in open chest dogs with constant cardiac output and varying ventricular rates following the left atrial injection of 99m-Tc human serum albumin. Values of LVEF obtained by first transit (high frequency) data analysis and ECG-gated scintiphotography were obtained over a wide range of ventricular rate and stroke volume. The results of this study show no significant difference in LVEF as determined by both of these methods of data acquisition and analysis and demonstrate the feasibility of rapid serial determination of LVEF by radioisotope techniques

  6. Evaluation of Tc-99m leukocyte scan in the diagnosis of acute appendicitis

    International Nuclear Information System (INIS)

    Butler, J.A.; Marcus, C.S.; Henneman, P.L.; Inkelis, S.H.; Wilson, S.E.

    1987-01-01

    A new /sup 99m/Tc Microlite leukocyte scan was performed in 38 patients to assess its value in the diagnosis of acute appendicitis. Autologous leukocytes are labeled with /sup 99m/Tc by inducing phagocytosis of /sup 99m/Tc albumin microcolloid particles. The advantages of this test over the standard indium-111 scan include superior imaging capability, a marked reduction (greater than 75%) in the radiation dose, and performance of the test including labeling, in less than 3 hr. Imaging is performed at 5-90 min postinjection of labeled cells. There were 19 male and 19 female patients with ages ranging from 10 to 80 years, in whom the diagnosis of appendicitis was indeterminate on clinical examination. Of the 13 of the 38 patients (34%) who came to surgery 12 had acute appendicitis. The WBC scan correctly identified 10 of the 12 cases of appendicitis. There were two false-negative studies. In the nonoperative group of 25 patients admitted for observation, 21 studies were reported as negative and four identified other sites of inflammation. All patients with a negative study have remained asymptomatic on follow-up. With a sensitivity of 83% (10/12) and a specificity of 100% (26/26) the /sup 99m/Tc leukocyte scan provides a rapid and highly accurate method for diagnosis of appendicitis in this preliminary study of patients with equivocal clinical exams

  7. Myocardial perfusion scintigraphy with technetium 99m-MIBI in the diagnosis of coronary artery disease in women

    International Nuclear Information System (INIS)

    Peix, C. Amalia; Chacon, Deylis; Llerena, Lorenzo; Torres, Maritza; Garcia, Ernesto Javier; Cabrera, Lazaro Omar

    2006-01-01

    The results of technetium 99 m - methoxy-isobutyl-isonitrile scintigraphy in a one-day protocol: rest - physical or combined stress bicycle plus endovenoous dipyridamole were compared with those of coronary angiography in 20 women referred for the evaluation of pre cordial pain and of the usefulness of myocardial perfusion scintigraphy. The uptake of the radio drug under stress and at rest varied from 93 + - 9 to 94 + - 7 % in the 204 segments with normal uptake under stress, from 67 He articulates it analyzes the reasons or utility of the employment of the radioactive iodine in the diagnosis and treatment of the thyroid affections + - 9 to 75 + - 17 % in the 89 with moderate reduction, and from 33 + - 9 to 64 + - 28 % in the 27 with severe reduction. The qualitative and quantitative uptake analyses coincided in 18 patients. The perfusion scintigraphy and the angiography agreed in 70 % of the patients. It was concluded that the myocardial perfusion scintigraphy with technetium 99 -MIBI contributes to the diagnosis of the coronary artery disease in women

  8. Biokinetic and dosimetry of {sup 99m}Tc-14F7-monoclonal antibody in patients with breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, Joaquin; Calderon, Carlos; Pimentel, Gilmara; Oliva, Juan P., E-mail: jgg@infomed.sld.cu [Departmento de Medicina Nuclear, Instituto de Oncologia y Radiobiologia, Cidad Habana (Cuba); Casaco, Angel [Division de Ensayos Clinicos, Centro de Inmunologia Molecular, Reparto Siboney, Ciudad Habana (Cuba)

    2008-07-01

    Full text: The 14F7 murine MAb is an IgG1 that binds specifically to GM3(Neu-Gc) ganglioside strongly recognizing the antigen displayed in human breast and melanoma tumors. A preliminary report showed in vivo evidences of presence of GM3(Neu-Gc) ganglioside in human breast primary tumors using 14F7 MAb labelled with {sup 99m}Tc. In this work the pharmacokinetics and biodistribution of {sup 99m}Tc-14F7 MAb in patient with breast cancer were studied. The absorbed dose in normal organ and tumors was also calculated. The patients were selected from a Phase I/II clinical trial which included 14 female patients with cytological diagnose of breast carcinoma in stage II without previous onco-specific treatment. Three groups were conformed: Group I (0.3mg, n=5), Group II (1mg, n=5) and Group III (3mg, n=4). The activity ranged in 1.11 - 1.48GBq (30- 40mCi) was intravenously administered during 1-2min. The {sup 99m}Tc-14F7 plasma clearance was determined by blood sampling at 5, 10, 20, 30min and 1, 2, 4, 8 and 24h after injection. All urine excreted by patients was collected during 24h after injection at intervals of 0-2h, 2-8h and 8-24h. Prior to injection, a transmission scan of head, thorax, abdomen and pelvis was obtained using a {sup 57}Co flood source. Anterior and posterior whole body images were acquired at 30min, 2h, 4h, 8h and 24h after injection using a Gamma Camera (SophyCamera DS7) with pinhole collimator. Static anterior and posterior images were obtained from head, thorax, abdomen, pelvis and lateral images of each breast in pendular position at 2h, 4h, 8h and 24h. Internal absorbed dose calculation was performed according to MIRD formalism using the S values for adult non-pregnant female phantom downloaded from the RADAR website. Self-absorbed tumor dose were calculated assuming those as spheres with uniform distribution of activity. The plasma clearance of radiotracer in all groups shows a monoexponential decay behaviour with biological elimination half time

  9. Instant thin layer chromatography (ITLC) - the most true and convenient method for the determination of radiochemical purity of Tc-99m Labeled radiopharmaceuticals

    International Nuclear Information System (INIS)

    Anwar-Ul-Azim, M.; Ansari, M.I.H.

    2007-01-01

    Full text: Determination of radiochemical purity usually involves paper chromatography method or some column chromatography such as ion exchange or gel filtration technique. In this study, a modified chromatography method with thin-layer support called instant thin Layer chromatography (ITLC) was used for the measurement of radiochemical purity. The aim of the study was to present instant thin layer chromatography-Silica-Gel (ITLC-SG) technique as a fairly rapid , convenient and inexpensive system for the screening of radiochemical impurities of 99mTc-labeled radiopharmaceuticals resulting from physical , chemical and/or radiation decomposition. Materials and Methods: The experiment was carried out at the Institute of Nuclear Medicine and Ultrasound, Dhaka for a period of 10 months from August '05 to May '06. Radiochemical purity of seven types of 99mTc-labeled radiopharmaceuticals, namely 99mTc-DTPA,99mTc- MI I, 99m Tc - HDP, 99m Tc - DMSA, 99m Tc - Tetofosmin, 99mTc-Fyton and 99mTc-ECD were measured by the use of two solvent dual-instant thin layer chromatography systems. Commercially available instant thin layer chromatography plate ( 20cm x20cm) impregnated with silica gel (ITLC-SG: Merck, Germany) was used as a stationary phase for the measurement of radiochemical impurities.Acetone, Ethyl methyl ketone, chloroform and methanol were used to measure the amount of free pertechnetate in the labelled radiopharmaceuticals and 0.9% saline was used in all cases as solvent (Mobile phase) to measure the amount of the hydrolyzed-reduced technetium colloid. Results: The results showed that the measured radiochemical purity of 99mTc-DTPA, 99mTc-MIBI, 99mTc-HDP, 99mTc-DMSA, 99mTc-Tetofosmin, 99mTc-Fyton and 99mTc-ECD were acceptable for all the studied samples except two samples of 99mTc-MIBI, one sample of 99mTc-Fyton and two samples of 99mTc-ECD, where the measured radiochemical purity were not within the acceptable RCP limits of commonly used radiopharmaceuticals (RCP

  10. Synthesis, characterization and biological evaluation of a novel "3 + 1" mixed ligand 99mTc complex having an aliphatic thiol as coligand.

    Science.gov (United States)

    Rey, A; Papadopoulos, M; Leon, E; Mallo, L; Pirmettis, Y; Manta, E; Raptopoulou, C; Chiotellis, E; Leon, A

    2001-03-01

    A novel "3 + 1" mixed ligand 99mTc complex with N,N-bis(2-mercaptoethyl)-N'N'-diethyl-ethilenediamine as ligand and 1-octanethiol as coligand was prepared and evaluated as potential brain radiopharmaceutical. Preparation at tracer level was accomplished by substitution, using 99mTc-glucoheptonate as precursor and a coligand/ligand ratio of 5. Under these conditions the labeling yield was over 80% and a major product with radiochemical purity >80% was isolated by HPLC methods and used for biological evaluation. Chemical characterization at carrier level was developed using the corresponding rhenium and 99gTc complexes. Results were consistent with the expected "3 + 1" structure and X-ray diffraction study demonstrated that the complex adopted a distorted trigonal bipyramidal geometry. All sulphur atoms underwent ionization leading to the formation of a neutral compound. Biodistribution in mice demonstrated early brain uptake, fast blood clearance and excretion through hepatobiliary system. Although brain/blood ratio increased significantly with time, this novel 99mTc complex did not exhibit ideal properties as brain perfusion radiopharmaceutical since brain uptake was too low.

  11. Observations of super early left ventricular remodeling experimental myocardial infarction

    International Nuclear Information System (INIS)

    Zhang, C.G.; Jin, J.H.; Zhao, X.B.; Kang, C.S.; Liang, F.Y.; Yin, Z.M.; Liu, G.F.; Li, S.J.; Li, X.F.; Hu, G.; Qin, D.Z.; Song, L.Z.

    2004-01-01

    Purpose: Ventricular remodeling is defined as the changes in the shape and size of the entire left ventricle after acute myocardial infarction (AMI). Many investigators have shown that left ventricular remodeling is related to clinical outcomes, including mortality, that represent the natural history, of the heart failure syndrome. The aim of this study was to demonstrate that it is possible to observe super early left ventricular remodeling by 99mTc-MIBI myocardial imaging in the dog model of acute experimental myocardial infarction. Methods: Experimental subjects: Twenty-three healthy mongrel dogs (14-25 kg) of either sex were studied under general anesthesia (sodium pentobarbital, 30 mg/kg). The left anterior descending (LAD) coronary artery was dissected and ligated between the first and second diagonal branches. Seven dogs died of ventricular fibrillation after the LAD coronary artery ligation. The 16 remaining dogs were divided into two groups: Group A (GA) received 99mTc-MIBI myocardial imaging (n=8): Group B (GB) received 99mTc-MIBI myocardial imaging combined with echocardiography (n=8). 99mTc-MIBI myocardial perfusion imaging :Static 99mTc-MIBI myocardial imaging was taken with ADAC Vertex Dual-head SPECT. 99mTc-MIBI kit was manufactured in Syncor, China. Each dog served as its own control, and was scanned by 99mTc-MIBI myocardial imaging and chocardiography at 48-72 hours before ligation. The mean time of the first acquisition was 21.87 ± 11.03 (14-48) minutes post-operatively in GA, 57.63±22.83 (30-99) minutes for 99mTc-MIBI imaging in GB, 26.00±15.07 (12-50) minutes for echocardiography in GB. Acquisition techniques for Gated SPECT: ECG synchronized data collection: R wave trigger, 8 Frames/Cardiac cycle. Images were gathered by rotating the detectors 180 degrees at 6 degrees per frame. Each frame took 40 seconds. The dog position was supine. The images were acquired and recorded for 6 hours following the LAD coronary artery ligation. After 6 hours

  12. Assessment of response of limb sarcoma to neoadjuant chemotherapy with Tc99m SESTAMIBI

    International Nuclear Information System (INIS)

    Krishnakumar, R.; Priyadarshini, R.; Begum, Balkis; Manivannan, K.; Shanmugasundaram, B.; Anuradha, S.

    2004-01-01

    Full text: Osteosarcoma is one of the malignant tumours, which spreads locally by breaking the periosteum. With the introduction of cytotoxic drugs as neo-adjuant chemotherapy, aggressive mutilating surgeries have decreased. CT/MRI though very useful in assessing the local response, nuclear medicine imaging procedures are reported to be more specific. Sestamibi, a myocardial perfusion-scanning agent also concentrates in tumours. The study is aimed at the evaluation of MIBI (Cardiolite) imaging in assessing the response of neo-adjuant chemotherapy in limb sarcomas (both bone and soft tissue tumours) before conservative resection. About 25-30 mCi of 99mTc MIBI is given intravenously followed by dynamic images for 1-2 minutes and thereafter static images at 30min., 1 hr. and 2 hours of injection. 62 patients (Osteosarcoma -35, Ewing's sarcoma -15, Rhabdomyosarcoma -1 and Soft Tissue sarcoma -1) were studied. 17 patients were dropped from the study as they progressed locally or developed metastases. Of the 35 patients having osteosarcoma, 30 patients were eligible for limb salvage surgery (LSS). 5 patients progressed locally and were not eligible for LSS and were advised amputation. Of the 10 Ewing's sarcoma patients, 7 were treated with chemotherapy, 2 underwent LSS and 1 was amputated. All these patients underwent 4 studies: 1st - baseline; 2nd- after 3 courses of chemo; 3rd - after 6 courses of chemo; 4th-after 12 cycles of chemotherapy. There were no demonstrable abnormal focal concentrations in the abdomen or elsewhere in any of these patients suggestive of metastases. The tumour site showed avid uptake. Quantitative estimation of the uptake was done. The ratios of uptake in the tumor site to the corresponding uninvolved site were calculated at different intervals viz. 5 min, 30min, 60min, 90min and 2hrs. The wash off rates of the tracer from the tumour sites at different interval was also analysed. We noticed that in patients where the ratio in the 1st and 2nd

  13. Scintigraphic scoring system for grading severity of gastro-esophageal reflux on 99mTc sulfur colloid gastro-esophageal reflux scintigraphy: A prospective study of 39 cases with pre and post treatment assessment.

    Science.gov (United States)

    Puranik, Ameya D; Nair, Gopinathan; Aggarwal, Rajiv; Bandyopadhyay, Abhijit; Shinto, Ajit; Zade, Anand

    2013-04-01

    The study aimed at developing a scoring system for scintigraphic grading of gastro-esophageal reflux (GER), on gastro-esophageal reflux scintigraphy (GERS) and comparison of clinical and scintigraphic scores, pre- and post-treatment. A total of 39 cases with clinically symptomatic GER underwent 99mTc sulfur colloid GERS; scores were assigned based on the clinical and scintigraphic parameters. Post domperidone GERS was performed after completion of treatment. Follow up GERS was performed and clinical and scintigraphic parameters were compared with baseline parameters. Paired t-test on pre and post domperidone treatment clinical scores showed that the decline in post-treatment scores was highly significant, with P value reflux and also for following children post-treatment.

  14. Study of the properties of sup(99m)Tc-DTPA-ferroascorbinate and sup(99m)Tc-dextrose as radiopharmaceuticals for renal scintiscanning

    International Nuclear Information System (INIS)

    Salambashev, L.; Konstantinov, P.; Ketskarova, S.; Kovacheva, S.; Babeva, S.

    1979-01-01

    Description is made of an own method for labelling of the complex DTPA-ferroascorbinate and dextrose with sup(99m)Tc for the purpose of renal scintiscanning. Experimental investigations on rabbits were carried out, and afterwards conventional scintiscanning and follow-up of the intake into the renal parenchyma by means of gamma camera were performed on 15 patients. The observations revealed that sup(99m)Tc-DTPA-ferroascorbinate was more rapidly excreted (40 min to 2 h following the intravenous administration). For this reason it is more convenient for gamma camera examination, while sup(99m)Tc-dextrose is fixing more lastingly in the parenchyma and respons to all requirements with respect to radiopharmaceuticals for conventional renal scintiscanning. (author)

  15. Cerebral perfution studies

    International Nuclear Information System (INIS)

    Mut, Fernando

    1994-01-01

    For detecting in precocious form a coronary disease is necessary to aply a diagnostic techniques. The main considerations to be indicated in the present work are: physiological considerations, myocardial perfusion studies with radiotracers such as Talio 201, 99mTc, MIBI, 99mTc-Teboroxima, 99mTc-Fosfinas, instrumentation for obtain good images, proceedings protocols, studies interpretation, standards, SPECT, anomalies standards, coronary diseases

  16. Cerebral perfution studies; Estudios de Perfusion Cerebral

    Energy Technology Data Exchange (ETDEWEB)

    Mut, Fernando [Universidad de la Republica, Montevideo (Uruguay). Centro de Medicina Nuclear

    1994-12-31

    For detecting in precocious form a coronary disease is necessary to aply a diagnostic techniques. The main considerations to be indicated in the present work are: physiological considerations, myocardial perfusion studies with radiotracers such as Talio 201, 99mTc, MIBI, 99mTc-Teboroxima, 99mTc-Fosfinas, instrumentation for obtain good images, proceedings protocols, studies interpretation, standards, SPECT, anomalies standards, coronary diseases.

  17. Myocardial perfusion studies in coronary diseases; Estudios de Perfusion Miocardica en la Enfermedad Coronaria

    Energy Technology Data Exchange (ETDEWEB)

    Mut, Fernando [Universidad de la Republica, Montevideo (Uruguay)

    1994-12-31

    For detecting in precocious form a coronary disease is necessary to apply a diagnostic techniques. The main considerations to be indicated in the present work are: physiological considerations, myocardial perfusion studies with radiotracers such as Talio 201, 99mTc, MIBI, 99mTc-Teboroxima, 99mTc-Fosfinas, instrumentation for obtain good images,proceedings protocols, studies interpretation, standards, SPECT, anomalies standards, coronary diseases.

  18. Myocardial perfusion studies in coronary diseases

    International Nuclear Information System (INIS)

    Mut, Fernando

    1994-01-01

    For detecting in precocious form a coronary disease is necessary to apply a diagnostic techniques. The main considerations to be indicated in the present work are: physiological considerations, myocardial perfusion studies with radiotracers such as Talio 201, 99mTc, MIBI, 99mTc-Teboroxima, 99mTc-Fosfinas, instrumentation for obtain good images,proceedings protocols, studies interpretation, standards, SPECT, anomalies standards, coronary diseases

  19. The effect of dimethyl sulfoxide on the induction of DNA strand breaks in plasmid DNA and colony formation of PC Cl3 mammalian cells by alpha-, beta-, and Auger electron emitters (223)Ra, (188)Re, and (99m)Tc.

    Science.gov (United States)

    Runge, Roswitha; Oehme, Liane; Kotzerke, Jörg; Freudenberg, Robert

    2016-12-01

    DNA damage occurs as a consequence of both direct and indirect effects of ionizing radiation. The severity of DNA damage depends on the physical characteristics of the radiation quality, e.g., the linear energy transfer (LET). There are still contrary findings regarding direct or indirect interactions of high-LET emitters with DNA. Our aim is to determine DNA damage and the effect on cellular survival induced by (223)Ra compared to (188)Re and (99m)Tc modulated by the radical scavenger dimethyl sulfoxide (DMSO). Radioactive solutions of (223)Ra, (188)Re, or (99m)Tc were added to either plasmid DNA or to PC Cl3 cells in the absence or presence of DMSO. Following irradiation, single strand breaks (SSB) and double strand breaks (DSB) in plasmid DNA were analyzed by gel electrophoresis. To determine the radiosensitivity of the rat thyroid cell line (PC Cl3), survival curves were performed using the colony formation assay. Exposure to 120 Gy of (223)Ra, (188)Re, or (99m)Tc leads to maximal yields of SSB (80 %) in plasmid DNA. Irradiation with 540 Gy (223)Ra and 500 Gy (188)Re or (99m)Tc induced 40, 28, and 64 % linear plasmid conformations, respectively. DMSO prevented the SSB and DSB in a similar way for all radionuclides. However, with the α-emitter (223)Ra, a low level of DSB could not be prevented by DMSO. Irradiation of PC Cl3 cells with (223)Ra, (188)Re, and (99m)Tc pre-incubated with DMSO revealed enhanced survival fractions (SF) in comparison to treatment without DMSO. Protection factors (PF) were calculated using the fitted survival curves. These factors are 1.23 ± 0.04, 1.20 ± 0.19, and 1.34 ± 0.05 for (223)Ra, (188)Re, and (99m)Tc, respectively. For (223)Ra, as well as for (188)Re and (99m)Tc, dose-dependent radiation effects were found applicable for plasmid DNA and PC Cl3 cells. The radioprotection by DMSO was in the same range for high- and low-LET emitter. Overall, the results indicate the contribution of mainly indirect radiation

  20. Determination of Tc-99 in radioactive wastes; Determinacion de Tc-99 en desechos radiactivos

    Energy Technology Data Exchange (ETDEWEB)

    Rivera S, A. A.

    2015-07-01

    Tc-99 is a fission product and one of the most important radionuclides from the view point of safety assessment for the disposal of radioactive waste because of its long half-life (2.1 x 10{sup 5} years) and high mobility in soil-water systems, if this is released into the environment in significant quantities can concentrate on plants and animals. Tc-99 is a pure beta emitter with a maximum energy of 292 KeV, so their quantification imposes destructive methods to be analyzed by liquid scintillation. Therefore the quantification of Tc-99 in ion exchange resins requires of the mineralization of these and separation of Tc-99 of other radioisotopes present in the resin. Therefore the object of this thesis is to develop a quantification method of Tc-99 content in spent exchange resins. So in order to track the behavior of technetium during digestion exchange resins and radiochemical separation, given its high volatility, in this work the {sup 99m}Tc is used. To determine the degree of mineralization of the resins, an analysis was performed by chromatography. Subsequently the method used to determine the percentage of {sup 99m}Tc aerosolized during mineralization of resin is described. After the method for the radiochemical separation of {sup 99m}Tc is presented by liquid-liquid extraction using crown ether as extractant; for this testing was performed by varying the molarity of the extractant, the ratio of solvent extractant, type of digestion of the resin and the presence of Sr-85, in order to study the behavior of {sup 99m}Tc in the presence of this radioisotope. Finally, a track beta spectra of a sample of {sup 99m}Tc eluted from a generator {sup 99}Mo/{sup 99m}Tc function of time was performed. (Author)

  1. Comparison of fluorine-18 fluorodeoxyglucose positron emission tomography and technetium-99m methoxyisobutylisonitrile scintimammography in the detection of breast tumours

    Energy Technology Data Exchange (ETDEWEB)

    Palmedo, H.; Bender, H.; Gruenwald, F.; Zamora, P.; Biersack, H.J. [Department of Nuclear Medicine, University of Bonn (Germany); Mallmann, P.; Krebs, D. [Department of Gynecology and Obstetrics, University of Bonn (Germany)

    1997-09-01

    The aim of this study was to compare, in breast cancer patients, the diagnostic accuracy of positron emission tomography (PET) using fluorine-18 fluorodeoxyglucose (FDG) and scintimammography (SMM) using technetium-99m methoxyisobutylisonitrile (MIBI). A total of 20 patients (40 breasts with 22 lesions) were evaluated serially with MIBI and, on the following day, with FDG. For SMM, planar and single-photon emission tomography imaging in the prone position was performed starting at 10 min following the injection of MIBI (740 MBq). For PET, scans were acquired 45-60 min after the injection of FDG (370 MBq) and attentuation correction was performed following transmission scans. Results from SMM and PET were subsequently compared with the histopathology results. True-positive results were obtained in 12/13 primary breast cancers (mean diameter=29 mm, range 8-53 mm) with both FDG and MIBI. False-negative results were obtained in two local recurrences (diameter <9 mm) with both FDG and MIBI. In benign disease, FDG and MIBI did not localize three fibrocystic lesions, two fibroadenomas and one inflammatory lesion (true-negative), but both localized one fibroadenoma (false-positive). Collectively, the results demonstrate a sensitivity of 92%, and a specificity of 86%, for primary breast cancer regardless of whether FDG or MIBI was used. In contrast to MIBI scintigraphy, FDG PET scored the axillae correctly as either positive (metastatic disease) or negative (no axillary disease) in all 12 patients. The tumour/non-tumour ratio for MIBI was 1.97 (range 1.43-3.1). The mean standard uptake value (SUV) for FDG uptake was 2.57 (range 0.3-6.2). The diagnostic accuracy of SMM was equivalent to that of FDG PET for the detection of primary breast cancer. For the detection of in situ lymph node metastases of the axilla, FDG seems to be more sensitive than {sup 99m}Tc-MIBI. (orig.). With 4 figs., 2 tabs.

  2. A comparative study of 99Tcm-MIBI exercise myocardial perfusion imaging and the coronary arteriography in the diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Huang Xiaohong; Yan Aiping; Li Yuren; Hou Zhenwen; Jiang Ningyi; Lu Xianping

    2003-01-01

    Objective: A comparative evaluation of 99 Tc m -MIBI exercise myocardial perfusion imaging (MPI) and coronary arteriography (CAG) in diagnosis of coronary artery disease. Methods: MPI and CAG were performed on 92 patients with clinical equivocal diagnosis of coronary artery disease. The results were comparatively studied. Results: The sensitivity and specificity of MPI were 83.9% and 69.1%. Both modalities matched in 78.3% cases. Conclusion: MPI offers useful information for the diagnosis of coronary artery disease. And patients with a normal MPI don't need a further coronary angiography

  3. Significance of 99mTc-MIBI myocardial SPECT imaging in diagnosis of syndrome X

    International Nuclear Information System (INIS)

    Tian Yueqing; Liu Xiujie; Jiao Shubin

    1996-01-01

    To assess the value of myocardial imaging in the diagnosis of syndrome X, the study was performed with 99m Tc-MIBI myocardial SPECT imaging in 64 patients. The patients were divided into three groups: group 1 had 21 patients diagnosed as syndrome X, group 2 had 17 patients with chest pain and normal coronary arteries without ST segment depression during exercise, group 3 had 26 patients with the angina pectoris and coronary stenoses≥50%. The myocardial SPECT imaging of the three groups was compared qualitatively and semi-quantitatively. Myocardial imaging identified 11 cases of myocardial ischemia from 21 patients with syndrome X. The ischemic score of myocardial imaging was 1.1 +- 0.3 for syndrome X and 1.8 +- 0.7 for patients with coronary heart disease (CHD) angina pectoris (t = 3.1746, P<0.01). Myocardial imaging may partly show myocardial ischemia in patients with syndrome X. The extent of ischemia in patients with syndrome X was significantly less than that in patients with CHD angina pectoris

  4. {sup 99m}Tc-labeled-1-thio-{beta}-D-glucose as a new tool to temporomandibular joint inflammatory disorders diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Borges Brasileiro, Claudia, E-mail: cbbrasileiro@gmail.co [Departamento de Engenharia Nuclear-PCA, Escola de Engenharia, Universidade Federal de Minas Gerais (UFMG)-Avenida Presidente Antonio Carlos, 6627, CEP: 31270-100 Belo Horizonte, MG (Brazil); Fonseca Pacheco, Cinthia Mara da, E-mail: cinthia@newtonpaiva.b [Faculdade de Ciencias Biologicas e da Saude, Centro Universitario Newton Paiva-Avenida Silva Lobo, 1730, Belo Horizonte, MG (Brazil); Martins Queiroz-Junior, Celso, E-mail: cmqj@yahoo.com.b [Departamento de Clinica, Patologia e Cirurgia Odontologica, Faculdade de Odontologia, Universidade Federal de Minas Gerais (UFMG)-Avenida Presidente Antonio Carlos, 6627, Belo Horizonte, MG (Brazil); Flavia de Lima, Carla, E-mail: carla.flavia@terra.com.b [Nucleo de Diagnostico Cardiovascular (ECOGRAF)-Rua dos Otoni, 881, Belo Horizonte, MG (Brazil); Batista da Silva, Juliana, E-mail: silvajb@cdtn.b [Unidade de Pesquisa e Producao de Radiofarmacos, Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN)-Avenida Presidente Antonio Carlos, 6627, Belo Horizonte, MG (Brazil); Passos Ribeiro de Campos, Tarcisio, E-mail: campos@nuclear.ufmb.b [Departamento de Engenharia Nuclear-PCA, Escola de Engenharia, Universidade Federal de Minas Gerais (UFMG)-Avenida Presidente Antonio Carlos, 6627, CEP: 31270-100 Belo Horizonte, MG (Brazil)

    2010-12-15

    Aim: The aim of this study was to evaluate early detection of temporomandibular joint (TMJ) inflammatory changes based on 1-thio-{beta}-D-glucose radiolabeled with technetium-99m. Method: The method applied a TMJ inflammation model in rats followed by radiopharmaceutical synthesis, intravenous administration of {sup 99m}Tc-1-TG and kinetic scintigraphy imaging. Results: Results show a significant difference of {sup 99m}Tc-1-TG uptake between inflamed TMJ and the control joint. The biodistribution of {sup 99m}Tc-1-TG by images showed the kidneys' excretion. Conclusion: As conclusion, {sup 99m}Tc-1-TG is a helpful tool in TMJ inflammatory process detection.

  5. Separation of 99Tc from irradiated molybdenum oxide by extraction with trioctilamine

    International Nuclear Information System (INIS)

    Carvalho, O.G. de.

    1979-01-01

    A separation method of sup( 99 m)Tc, from irradiated molybdenum oxide, by extraction with trioctilamino in 1,2 dichloroethane, 2% v/v is studied. Two preliminary studies are done: 1) Stablishment of the shaking time necessary to reach the equilibrium between the organic and the aqueous phase; 2) Choice of the concentration of solution of TOA in 1,2 dichloroethane to obtain the best separation conditions of sup( 99 m)Tc. After stablishing these two parameters, the study of extraction in solutions of hydrochloric nitric and sulfuric acids in different concentrations is done, followed by the study of the variation of extraction percentage of sup( 99 m)Tc in relation to the molybdenum oxide mass and the back-extraction of sup( 99 m)Tc to the aqueous phase with solutions of perchloric acid 1,0 and 0,1 N and ammonium hydroxide 1,0 N. (Author) [pt

  6. Cyclopentadienyl tricarbonyl complexes of 99mTc for the in vivo imaging of the serotonin 5-HT 1a receptor in the brain

    International Nuclear Information System (INIS)

    Saidi, Mouldi; Trabelsi, Adel; MEKNI, Abdelkader; Kretzschmar, M.; Sefert, S.; Bergmann, R.; Pietzsch, H.-J.

    2005-01-01

    The present interest in the 5-HT 1a receptor is due to its implicated role in several major neuropsychiatric disorders such as depression, eating disorders and anxiety. For the diagnosis of these pathophysiological processes it is important to have radioligands in hand able to specifically bind on the 5-HT 1a receptor in order to allow brain imaging. due to the optimal radiation properties of 99mTc there is a considerable interest in the development of 99mTc radiopharmaceuticals for imaging serotonergic CNS receptors using single-photon emission tomography (SPET). Here we introduce two cyclopentadienyl technitium tricarbonyl conjugates of piperidine derivatives which show high accumulation of radioactivity in brain areas rich in 5-HT 1a receptors

  7. Fatores de correção volumétrica na medição de atividade de 99mTc e 123I em calibradores de radionuclídeos

    Directory of Open Access Journals (Sweden)

    Amanda Ribeiro Correia

    2012-04-01

    Full Text Available OBJETIVO: Determinar os fatores de correção para a variação volumétrica dos radiofármacos contidos em recipientes de diferentes geometrias. Comparar a influência desses fatores na determinação da atividade de 99mTc e 123I utilizando dois tipos de calibradores: um com câmara de ionização e outro com detector Geiger-Müller (G-M. Avaliar o desempenho de calibradores de alguns serviços de medicina nuclear em medição de atividade de 99mTc e 123I. MATERIAIS E MÉTODOS: Foram utilizados oito calibradores, frascos de vidro 10R, seringas de plástico de 3 e 5 mL e soluções de 99mTc e 123I. Os fatores de correção foram determinados a partir das medições práticas da variação da leitura do calibrador com a variação do volume da solução no recipiente. O desempenho foi avaliado em relação ao critério de aceitação de ±10% de exatidão exigida pela norma brasileira. RESULTADOS: A variação da resposta do calibrador com a variação do volume do frasco foi bem maior no calibrador que utiliza G-M. Ela também foi maior para 123I do que para 99mTc. CONCLUSÃO: Os resultados confirmam que a resposta dos calibradores depende do volume contido nos recipientes. Essa dependência é mais crítica para os calibradores equipados com detector G-M e para 123I quando comparado com 99mTc.

  8. MIBI scintigraphy in hypofunctioning thyroid nodules. Can it predict the dignity of the lesion?

    Energy Technology Data Exchange (ETDEWEB)

    Theissen, P.; Schmidt, M.; Ivanova, T.; Dietlein, M.; Schicha, H. [Dept. of Nuclear Medicine, Univ. of Cologne (Germany)

    2009-07-01

    Aim: Several authors have investigated the value of technetium-MIBI scanning to predict the dignity of hypofunctioning, cold thyroid nodules (HTN) in regions with differing levels of iodine supply. They concluded that an MIBI scan can exclude thyroid malignancy, although comparisons between the studies are of limited value owing to differences in methodology and wide variations in patient selection criteria. The present study investigates whether the above claim is also valid in Germany, a country with a long-standing and persistent, mild iodine deficiency and a high incidence of nodules in large goiters with a low prevalence of malignancy. Patients, methods: The study compares the results of {sup 99m}Tc-MIBI scintigraphy (incl. SPECT and planar images) in HTN (MIBI) with those of fine-needle aspiration biopsy (FNAB) and histology. Of 154 consecutive patients (121 women, 33 men; mean age 56 {+-} 12 years), 73 underwent thyroid surgery from which the results of FNAB and MIBI were assessed. Selection criteria were risk estimation or conditions limiting the feasibility of FNAB. The mean thyroid volume was 42 {+-} 25 ml, with 2.1 {+-} 1.4 nodules per patient. Results: Histology revealed thyroid malignancies in 8 out of 73 patients (11.0%). The negative predictive value for MIBI was 97%, which is comparable to FNAB (94%). However, in 19.5% of patients FNAB was indeterminate. Lower specificity (54%) and low positive predictive value (19%) showed that MIBI accumulation cannot differentiate between malignant and benign thyroid nodules. However, comparison with cytological and/or histological findings indicated that it could distinguish between lesions with differing rates of mitochondrial metabolism. Conclusion: Even in areas of former or mild iodine deficiency MIBI forms a basis for choosing between wait-and-see and surgical strategies if FNAB is unfeasible or not representative. However, even for pathological MIBI results, the prevalence of malignancy is not very high

  9. 16-Cyclopentadienyl tricarbonyl 99mTc 16-oxo-hexadecanoic acid: synthesis and evaluation of fatty acid metabolism in mouse myocardium.

    Science.gov (United States)

    Lee, Byung Chul; Kim, Dong Hyun; Lee, Iljung; Choe, Yearn Seong; Chi, Dae Yoon; Lee, Kyung-Han; Choi, Yong; Kim, Byung-Tae

    2008-06-26

    We synthesized 16-cyclopentadienyl tricarbonyl 99mTc 16-oxo-hexadecanoic acid (99mTc-CpTT-16-oxo-HDA, 1) and investigated its potential as a radiotracer for evaluating fatty acid metabolism in myocardium. Radiotracer 1 was synthesized in 22.6 +/- 6.3% decay-corrected yield by a double ligand transfer reaction between the ferrocene adduct of methyl hexadecanoate ( 2) and Na99mTcO 4 in the presence of Cr(CO)6 and CrCl3, followed by hydrolysis of the methyl ester group. Radiotracer 1 was found to be chemically stable (99% at 6 h) when incubated in human serum. A tissue distribution study in mice showed that high radioactivity accumulated in heart (9.03%ID/g at 1 min and 5.41%ID/g at 5 min postinjection) with rapid clearance and that heart to blood uptake ratios increased with time (2.13 at 5 min and 3.76 at 30 min postinjection). Metabolite analysis of the heart tissues using a simple extraction method showed that 99mTc-CpTT-4-oxo-butyric acid was detected as the major radioactive metabolite by HPLC, suggesting that 1 is metabolized to 99mTc-CpTT-4-oxo-butyric acid via beta-oxidation in myocardium.

  10. Determination of Sn in 99{sup m}Tc Radiopharmaceutical Kits by Polarographic Methods; Determinacion de Estano en Radiofarmacos de 99{sup m}Tc mediante Metodos Polarograficos

    Energy Technology Data Exchange (ETDEWEB)

    Castro, M; Cruz, J; Sanchez, M

    2009-07-01

    Kits of 99{sup m}Tc radiopharmaceuticals are used in nuclear medicine for diagnosis of different diseases. Sn (II) is one of the essential components in their formulations, which is used for reduction 99{sup m}Tc-pertechnetate in cold kits for on-site preparation 99{sup m}Tc-pertechnetate radiopharmaceuticals. Usually, these cold kits contain different additives (complexing agents, antioxidants, buffers, etc.) and the amount of Sn (II) varies from kit to kit. The determination of Sn in these products is essential in assessing their quality. We report here the development of a new polarographic method for the determination of Sn (II) and total Sn in representative radiopharmaceuticals kits (for the content of Sn and chemical composition) produced at the Center of Isotopes of Cuba (CENTIS). These methods were validated by analysis of variance and recovery techniques. From the results of the validation, the characteristic functions of uncertainties and fits are considered for the established methods, which give the necessary evidences to demonstrate the usefulness of these methods according to the current trends in Analytical Chemistry. This work provides practical results of great importance for CENTIS. After the speciation of Sn in the MAG3 radiopharmaceuticals kit is inferred that the production process is affected by uncontrolled factors that influence in the product stability, which demonstrates the necessity for analytical tools for the characterization of products and processes. (Author) 57 refs.

  11. Scintigraphic images of bacterial infection using aptamers directly labeled with {sup 99m}Tc

    Energy Technology Data Exchange (ETDEWEB)

    Santos, S.R.; Correa, C.R.; Andrade, A.S.R., E-mail: sararoberta7@hotmail.com, E-mail: crisrcorrea@gmail.com, E-mail: antero@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Barros, A.L.B.; Diniz, S.O.F.; Cardoso, V.N., E-mail: brancodebarros@yahoo.com.br, E-mail: valbertcardoso@yahoo.com.br, E-mail: simoneodilia@yahoo.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Faculdade de Farmacia. Departamento de Analises Clinicas e Toxicologicas

    2015-07-01

    Staphylococcus aureus is specie of great medical importance and is the most commonly agent found in infections of soft tissues, bone infections and bone prostheses. In this study, aptamers selected to S. aureus were labeled by the direct method with {sup 99m}Tc and used for bacterial infection identification by scintigraphy. The radiolabeled aptamers radiochemical purity and stability were assessed by thin-layer chromatography (TLC). Three groups of Swiss mice (n=6) were used for the scintigraphic imaging studies. The first group was infected intramuscularly in the right thigh with S. aureus, the second group with C. albicans and the third group received zymosan to induce aseptic inflammation. After 24 h, radiolabeled aptamers (18 MBq) were injected by the tail vein. Scintigraphic images were acquired at 1 h and 4 h postinjection. The radiolabeling yield with {sup 99m}Tc was over 90%. The radiolabeled aptamers were stable in 0.9% saline, plasma and cysteine excess. The scintigraphic image profiles showed high uptake in the kidneys and bladder in all groups, indicating a main renal excretion consistent with the hydrophilic nature of the molecule. No accumulation of radioactivity was observed in the thyroid, stomach, liver and spleen, indicating acceptable levels of radiochemical impurities. The group infected with S. aureus showed a visible uptake in the infected right thigh at 1 h post-injection. For the control groups (C. albicans and zymosan) visible differences between the right and left thighs were not observed. The radiolabeled aptamers were able to distinguish aseptic inflammation from bacterial infection and bacterial from fungal infection. (author)

  12. Gated 99mTc-MIBI single-photon emission computed tomography for the evaluation of left ventricular ejection fraction. Comparison with three-dimensional echocardiography

    International Nuclear Information System (INIS)

    Lipiec, P.; Wejner-Mik, P.; Krzeminska-Pakula, M.; Kapusta, A.; Kasprzak, J.D.; Kusmierek, J.; Plachcinska, A.; Szuminski, R.

    2008-01-01

    Parameters of left ventricular systolic function directly influence the management of patients with suspected coronary artery disease (CAD). Quantitative gated single-photon emission computed tomography (QGS; Cedars-Sinai Medical Center, Los Angeles, CA, USA) allows the computation of left ventricular ejection fraction (LVEF) from myocardial perfusion imaging studies which are frequently performed on patients with suspected CAD. Three-dimensional (3D) echocardiography is considered to be the echocardiographic ''gold standard'' for the quantification of LVEF. We sought to compare QGS with 3D echocardiography in the evaluation of EF in patients with suspected CAD. Ninety-one consecutive patients with suspected CAD, scheduled for coronary angiography, underwent rest electrocardiographic-gated technetium-99m methoxyisobutylisonitrile SPECT (G-SPECT) with measurement of LVEF by QGS and transthoracic 3D echocardiography with off-line measurement of LVEF (Tomtec 4D LV Analysis 1.1). The diagnosis of CAD was based on coronary angiography, performed on every patient. Nine patients were excluded from the analysis owing to unsuitability for 3D echocardiography (8 patients) or G-SPECT (1 patient). In the remaining group of 82 patients, 71 (87%) had significant CAD, 34 (42%) had a history of myocardial infarction, and 50 (61%) had perfusion defects at rest G-SPECT images. The mean LVEF measured by QGS and 3D echocardiography was 53±13% and 53±10%, respectively. The mean difference in LVEF between 3D echocardiography and QGS was 0.1±6.0% (P=0.87), and the correlation between the values obtained by both methods was high (r=0.88, P< 0.001). The largest discrepancies were observed in patients with small ventricular volumes. In patients undergoing diagnostic work-up for CAD, the measurement of LVEF by QGS algorithm provides high correlation and satisfactory agreement with the results of reference ultrasound method- 3D echocardiography. (author)

  13. Spent 99Mo/99mTc generator as an economical source of 99Mo

    International Nuclear Information System (INIS)

    El-Kolaly, M.T.

    1990-01-01

    An improved method for utilization and purification of 99 Mo from spent 90 Mo/ 99m Tc generators has been described. After washing the generator with saline to remove the generated 99m Tc, followed by 2 mL 5 M NaOH containing a few drops of H 2 O 2 , the 99 Mo was quantitatively eluted from the generator with 5 mL 5 M NaOH. The alkaline eluate containing 99 Mo was contaminated with partially dissolved alumina. In the present method, an anion-exchange resin Dowex 1 x 8 column was used for purification of 99 Mo from the contaminating alumina. The resultant 99 Mo was of high purity and contained 3+ /mL 99 Mo solution, as estimated by atomic absorption. (author)

  14. Synthesis and Preliminary Evaluation of a New 99mTc Labeled Substance P Analogue as a Potential Tumor Imaging Agent

    Science.gov (United States)

    Mozaffari, Saeed; Erfani, Mostafa; Beiki, Davood; Johari Daha, Fariba; Kobarfard, Farzad; Balalaie, Saeed; Fallahi, Babak

    2015-01-01

    Neurokinin 1 receptors (NK1R) are overexpressed on several types of important human cancer cells. Substance P (SP) is the most specific endogenous ligand known for NK1Rs. Accordingly,a new SP analogue was synthesized and evaluated for detection of NK1R positive tumors.[6-hydrazinopyridine-3-carboxylic acid (HYNIC)-Tyr8-Met(O)11-SP] was synthesized and radiolabeled with 99mTc using ethylenediamine-N,N'-diacetic acid (EDDA)and Tricine as coligands. Common physicochemical properties of radioconjugate were studied and in-vitro cell line biological tests were accomplished to determine the receptor mediated characteristics. In-vivo biodistribution in normal and tumor bearingnude mice was also assessed. The cold peptide was prepared in high purity (>99%) and radiolabeled with 99mTc at high specific activities (84-112GBq/µmol) with an acceptable labeling yield (>95%). The radioconjugate was stable in-vitro in the presence of human serum and showed 44% protein binding to human serumalbumin. In-vitro cell line studies on U373MG cells showed an acceptable uptake up to 4.91 ± 0.22% with the ratio of 60.21 ± 1.19% for its specific fraction and increasing specific internalization during 4 h. Receptor binding assays on U373MG cells indicated a mean Kd of 2.46 ± 0.43 nM and Bmax of 128925 ± 8145 sites/cell. In-vivo investigations determined the specific tumor uptake in 3.36 percent of injected dose per gram (%ID/g) for U373MG cells and noticeable accumulations of activity in the intestines and lung. Predominant renal excretion pathway was demonstrated. Therefore, this new radiolabeled peptide could be a promising radiotracer for detection of NK1R positive primary or secondary tumors. PMID:25561916

  15. Development of 4D mathematical observer models for the task-based evaluation of gated myocardial perfusion SPECT

    Science.gov (United States)

    Lee, Taek-Soo; Frey, Eric C.; Tsui, Benjamin M. W.

    2015-04-01

    This paper presents two 4D mathematical observer models for the detection of motion defects in 4D gated medical images. Their performance was compared with results from human observers in detecting a regional motion abnormality in simulated 4D gated myocardial perfusion (MP) SPECT images. The first 4D mathematical observer model extends the conventional channelized Hotelling observer (CHO) based on a set of 2D spatial channels and the second is a proposed model that uses a set of 4D space-time channels. Simulated projection data were generated using the 4D NURBS-based cardiac-torso (NCAT) phantom with 16 gates/cardiac cycle. The activity distribution modelled uptake of 99mTc MIBI with normal perfusion and a regional wall motion defect. An analytical projector was used in the simulation and the filtered backprojection (FBP) algorithm was used in image reconstruction followed by spatial and temporal low-pass filtering with various cut-off frequencies. Then, we extracted 2D image slices from each time frame and reorganized them into a set of cine images. For the first model, we applied 2D spatial channels to the cine images and generated a set of feature vectors that were stacked for the images from different slices of the heart. The process was repeated for each of the 1,024 noise realizations, and CHO and receiver operating characteristics (ROC) analysis methodologies were applied to the ensemble of the feature vectors to compute areas under the ROC curves (AUCs). For the second model, a set of 4D space-time channels was developed and applied to the sets of cine images to produce space-time feature vectors to which the CHO methodology was applied. The AUC values of the second model showed better agreement (Spearman’s rank correlation (SRC) coefficient = 0.8) to human observer results than those from the first model (SRC coefficient = 0.4). The agreement with human observers indicates the proposed 4D mathematical observer model provides a good predictor of the

  16. Study of different adsorbent materials for the preparation of generator systems of 99Mo - 99mTc and 188W-188Re

    International Nuclear Information System (INIS)

    Lopes, Paula Regina Corain

    2009-01-01

    Amongst some existing radioisotopes, 99m Tc and 188 Re present adequate physical chemical properties for use in Nuclear Medicine in the areas of diagnosis and therapy, respectively. Moreover, these radioisotopes can be distributed to medical centers in the form of generator systems of 99 Mo- 99m Tc and 188 W- 188 Re, allowing autonomy and practicity in use. The objective of this work consists of determining the capacity of some adsorbent materials for retention of molibdenium and tungsten, aiming the optimization of generator systems of 99 Mo- 99 mTc and 188 W- 188 Re with suitable characteristics for application in Nuclear Medicine. Known amounts, in mass, of molybdenum (Mo) and tungsten (W) were added to the loading solutions previously prepared, with values of pH adjusted between 1 and 7, and these were then percolated through different devices containing in its interior alumina, resin or poly-zirconium compound also known as PZC. The elutions were carried out within an interval of time of approximately 24 hours for the generator systems of 99 Mo - 99 mTc and 48 hours for the generator systems of 188 W- 188 Re due to the difference between the half-lives of radionuclides involved in the reactions. The eluted samples from both generator systems containing 99m Tc or 188 Re were submitted to quality control tests aiming to evaluate the radionuclidic, radiochemical and chemical purity, but no significant contamination for 99 Mo, 188 W, technetium or rhenium in the colloidal states and zirconium were detected in the eluted solutions and in the solutions extracted with saline solution for any value of pH studied. The commercial alumina cartridges known as Acid Sep Pak were more efficient in retaining the molybdenum in the loading solutions when compared with the others commercial retention devices employed. However, when this comparison extends to the chromatographic alumina columns, the use of acid alumina as adsorbent is more efficient when compared to the Acid Sep

  17. Semi-quantitative analysis of post-transarterial radioembolization 90Y Microsphere position emission tomography combined with computed tomography (PET/CT) images in advance liver malignancy: Comparison with 99mTc macroaggregated albumin (MAA) single photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    Rhee, Seung Hong; Kim, Sung Eun; Cho, Jae Hyuk; Park, Ju Kyung; Kim, Yun Hwan; Choe, Jae Gol; Eo, Jae Seon; Park, So Yeon; Lee, Eun Sub

    2016-01-01

    The purpose of this study is to evaluate the correlation between pretreatment planning technetium-99m ( 99 mTc) macroaggregated albumin (MAA) SPECT images and posttreatment transarterial radioembolization (TARE) yttirum-90 ( 90 Y) PET/CT images by comparing the ratios of tumor-to-normal liver counts. Fifty-two patients with advanced hepatic malignancy who underwent 90 Y microsphere radioembolization from January 2010 to December 2012 were retrospectively reviewed. Patients had undergone 99 mTc MAA intraarterial injection SPECT for a pretreatment evaluation of microsphere distribution and therapy planning. After the administration of 90 Y microspheres, the patients underwent posttreatment 90 Y PET/CT within 24 h. For semiquantitative analysis, the tumor-to-normal uptake ratios in 90 Y PET/CT (TNR-yp) and 99 mTc MAA SPECT (TNR-ms) as well as the tumor volumes measured in angiographic CT were obtained and analyzed. The relationship of TNR-yp and TNR-ms was evaluated by Spearman's rank correlation and Wilcoxon's matched pairs test. In a total of 79 lesions of 52 patients, the distribution of microspheres was well demonstrated in both the SPECT and PET/CT images. A good correlation was observed of between TNR-ms and TNR-yp (rho value = 0.648, p < 0.001). The TNR-yp (median 2.78, interquartile range 2.43) tend to show significantly higher values than TNR-ms (median 2.49, interquartile range of 1.55) (p = 0.012). The TNR-yp showed weak correlation with tumor volume (rho = 0.230, p = 0.041). The 99mTc MAA SPECT showed a good correlation with 90 Y PET/CT in TNR values, suggesting that 99 mTc MAA can be used as an adequate pretreatment evaluation method. However, the 99 mTc MAA SPECT image consistently shows lower TNR values compared to 90Y PET/CT, which means the possibility of underestimation of tumorous uptake in the partition dosimetry model using 99 mTc MAA SPECT. Considering that 99 mTc MAA is the only clinically available surrogate marker

  18. Computer assisted analysis of sup(99m)Tc pyrophosphate bone uptake in Paget's disease

    International Nuclear Information System (INIS)

    Maayan, M.L.; Eisenberg, J.; Volpert, E.; Shai, F.; Mroczek, R.

    1982-01-01

    The present clinical study describes a method of evaluation of Paget's disease bone by computer assisted analysis of activity curves obtained over normal and pathological portions of the skeleton in the same patient. The data obtained lead to a differential diagnosis between Paget's and metastatic disease of the bone, as well as an evaluation of subsequent therapy. The results indicate a higher bone activity, (expressed by bone flow and bone uptake, of sup(99m)Tc pyrophosphate) in Paget's than in metastatic disease of the bone, as well as a normalization of these parameters after prolonged therapy of Paget's patients with salmon calcitonin

  19. Use of 99mTc pertechnetate in patients with differentiated thyroid carcinoma

    International Nuclear Information System (INIS)

    Garcia del Rio, Hernan; Degrossi, Osvaldo J.; Pena, M.; Alvarez, L.; Faure, E.

    2006-01-01

    The possibility of using 99m Tc as an effective marker for the follow up of differentiated thyroid carcinoma is demonstrated. 99m Tc will avoid the blind use of radioiodine and it makes possible, in the case of rhTSH stimulation, to establish the need of 131 I therapy and the prompt application of this treatment [es

  20. Analytical and radiochemical methods in the stability study of the MIBI-Sm

    International Nuclear Information System (INIS)

    Isaac, M.; Leyva, R.; Gamboa, R.; Turino, D.

    1997-01-01

    99mT c-MIBI is a radiopharmaceutical imaging agent useful for assessing myocardial perfusion. This paper presents the stability results obtained in the radiochemical purity and others parameters in the quality control of 5 batch during more than 2 years