WorldWideScience

Sample records for focal length measurements

  1. Focal length measurement of a varifocal liquid lens with capacitance detection

    Science.gov (United States)

    Noda, Kentaro; Binh-Khiem, Nguyen; Takei, Yusuke; Takahata, Tomoyuki; Matsumoto, Kiyoshi; Shimoyama, Isao

    2014-04-01

    This paper reports on a detailed deformation model of varifocal liquid lenses fabricated by Parylene-on-liquid-deposition (POLD), which can be applied to measure and adjust the focal length of such lenses without using extra sensors or sensing mechanisms. The lens was fabricated by encapsulating a liquid between a transparent electrode and a polymer film that was covered with a metal electrode. When voltage is applied to the two electrodes, the lens deforms due to the electrostatic force, and its focal length and the capacitance between the two electrodes change simultaneously. This characteristic enables the focal length of the lens to be adjusted and detected by measuring the capacitance change. The focal length of the fabricated varifocal liquid lens changed from 153.6 to 82.6 mm by applying 150-V. The focal length change of the liquid lens was calculated from the change in its capacitance. Finally, to confirm the efficiency of this varifocal liquid lens, we fabricated a confocal distance sensor using the lens for laser scanning and demonstrated that this system can be used to measure distances of 94-140 mm with an average error of 0.83 mm and a standard deviation of 0.77 mm.

  2. Spherical aberration compensation method for long focal-length measurement based on Talbot interferometry

    Science.gov (United States)

    Luo, Yupeng; Huang, Xiao; Bai, Jian; Du, Juan; Liu, Qun; Luo, Yujie; Luo, Jia

    2017-08-01

    Large-aperture and long focal-length lens is widely used in high energy laser system. The method based on Talbot interferometry is a reliable method to measure the focal length of such elements. By employing divergent beam and two gratings of different periods, this method could realize full-aperture measurement, higher accuracy and better repeatability. However, it does not take into account the spherical aberration of the measured lens resulting in the moiré fringes bending, which will introduce measurement error. Furthermore, in long-focal measurement with divergent beam, this error is an important factor affecting the measurement accuracy. In this paper, we propose a new spherical aberration compensation method, which could significantly reduce the measurement error. Characterized by central-symmetric scanning window, the proposed method is based on the relationship between spherical aberration and the lens aperture. Angle data of moiré fringes in each scanning window is retrieved by Fourier analysis and statistically fitted to estimate a globally optimum value for spherical-aberration-free focal length calculation. Simulation and experiment have been carried out. Compared to the previous work, the proposed method is able to reduce the relative measurement error by 50%. The effect of scanning window size and shift step length on the results is also discussed.

  3. Measurement of contact angles of microscopic droplets by focal length method.

    Science.gov (United States)

    Geiger, Daniel; Geiger, Kirsten; Neckernuss, Tobias; Marti, Othmar; Amirkhani, Masoud

    2017-08-01

    We present a method to measure contact angles of microscopic droplets with a conventional microscope that possesses a precision focus adjustment stage. The droplets are modeled as spherical caps that act as lenses. Their focal length is determined by measuring the distance from the substrate surface to the level where a sharp image of the aperture stop is observed. The lens diameter is found by edge detection of a microscope image of the microdroplets. The spherical cap model relates the focal length and diameter of such lenses to the contact angle of the used liquid with known refractive index. The measurement procedure was applied to condensed water droplets on a silicon substrate covered by its native oxide layer. The results are found to be in good agreement with conventional, goniometric sessile drop measurements of the advancing contact angle.

  4. Continuously variable focal length lens

    Science.gov (United States)

    Adams, Bernhard W; Chollet, Matthieu C

    2013-12-17

    A material preferably in crystal form having a low atomic number such as beryllium (Z=4) provides for the focusing of x-rays in a continuously variable manner. The material is provided with plural spaced curvilinear, optically matched slots and/or recesses through which an x-ray beam is directed. The focal length of the material may be decreased or increased by increasing or decreasing, respectively, the number of slots (or recesses) through which the x-ray beam is directed, while fine tuning of the focal length is accomplished by rotation of the material so as to change the path length of the x-ray beam through the aligned cylindrical slows. X-ray analysis of a fixed point in a solid material may be performed by scanning the energy of the x-ray beam while rotating the material to maintain the beam's focal point at a fixed point in the specimen undergoing analysis.

  5. Sighting optics including an optical element having a first focal length and a second focal length

    Science.gov (United States)

    Crandall, David Lynn [Idaho Falls, ID

    2011-08-01

    One embodiment of sighting optics according to the teachings provided herein may include a front sight and a rear sight positioned in spaced-apart relation. The rear sight includes an optical element having a first focal length and a second focal length. The first focal length is selected so that it is about equal to a distance separating the optical element and the front sight and the second focal length is selected so that it is about equal to a target distance. The optical element thus brings into simultaneous focus, for a user, images of the front sight and the target.

  6. Focal Length Affects Depicted Shape and Perception of Facial Images.

    Directory of Open Access Journals (Sweden)

    Vít Třebický

    Full Text Available Static photographs are currently the most often employed stimuli in research on social perception. The method of photograph acquisition might affect the depicted subject's facial appearance and thus also the impression of such stimuli. An important factor influencing the resulting photograph is focal length, as different focal lengths produce various levels of image distortion. Here we tested whether different focal lengths (50, 85, 105 mm affect depicted shape and perception of female and male faces. We collected three portrait photographs of 45 (22 females, 23 males participants under standardized conditions and camera setting varying only in the focal length. Subsequently, the three photographs from each individual were shown on screen in a randomized order using a 3-alternative forced-choice paradigm. The images were judged for attractiveness, dominance, and femininity/masculinity by 369 raters (193 females, 176 males. Facial width-to-height ratio (fWHR was measured from each photograph and overall facial shape was analysed employing geometric morphometric methods (GMM. Our results showed that photographs taken with 50 mm focal length were rated as significantly less feminine/masculine, attractive, and dominant compared to the images taken with longer focal lengths. Further, shorter focal lengths produced faces with smaller fWHR. Subsequent GMM revealed focal length significantly affected overall facial shape of the photographed subjects. Thus methodology of photograph acquisition, focal length in this case, can significantly affect results of studies using photographic stimuli perhaps due to different levels of perspective distortion that influence shapes and proportions of morphological traits.

  7. Sighting optics including an optical element having a first focal length and a second focal length and methods for sighting

    Science.gov (United States)

    Crandall, David Lynn

    2011-08-16

    Sighting optics include a front sight and a rear sight positioned in a spaced-apart relation. The rear sight includes an optical element having a first focal length and a second focal length. The first focal length is selected so that it is about equal to a distance separating the optical element and the front sight and the second focal length is selected so that it is about equal to a target distance. The optical element thus brings into simultaneous focus for a user images of the front sight and the target.

  8. A potential individual cell malignancy indicator: focal length

    Science.gov (United States)

    Wang, Weina; Lear, Kevin L.

    2011-03-01

    The label-free technique of optofluidic intracavity spectroscopy (OFIS) utilizes the optical transmission spectrum of a cell in a microfluidic Fabry-Pérot (F-P) cavity to distinguish cells from cancerous cell lines and baseline normal blood cells. The classification between canine hemangiosarcoma (HSA) cancer cells and monocytes in canine normal peripheral blood mononuclear cells (PBMCs) had been demonstrated with 95% sensitivity and 98% specificity. Now with a new optical model that treats the cell settled at the bottom of the cavity as a thin lens, the focal length of cells was extracted and used as an individual cell malignancy indicator.

  9. Focal length estimation guided with object distribution on FocaLens dataset

    Science.gov (United States)

    Yan, Han; Zhang, Yu; Zhang, Shunli; Zhao, Sicong; Zhang, Li

    2017-05-01

    The focal length information of an image is indispensable for many computer vision tasks. In general, focal length can be obtained via camera calibration using specific planner patterns. However, for images taken by an unknown device, focal length can only be estimated based on the image itself. Currently, most of the single-image focal length estimation methods make use of predefined geometric cues (such as vanishing points or parallel lines) to infer focal length, which constrains their applications mainly on manmade scenes. The machine learning algorithms have demonstrated great performance in many computer vision tasks, but these methods are seldom used in the focal length estimation task, partially due to the shortage of labeled images for training the model. To bridge this gap, we first introduce a large-scale dataset FocaLens, which is especially designed for single-image focal length estimation. Taking advantage of the FocaLens dataset, we also propose a new focal length estimation model, which exploits the multiscale detection architecture to encode object distributions in images to assist focal length estimation. Additionally, an online focal transformation approach is proposed to further promote the model's generalization ability. Experimental results demonstrate that the proposed model trained on FocaLens can not only achieve state-of-the-art results on the scenes with distinct geometric cues but also obtain comparable results on the scenes even without distinct geometric cues.

  10. Dual-layer electrode-driven liquid crystal lens with electrically tunable focal length and focal plane

    Science.gov (United States)

    Zhang, Y. A.; Lin, C. F.; Lin, J. P.; Zeng, X. Y.; Yan, Q.; Zhou, X. T.; Guo, T. L.

    2018-04-01

    Electric-field-driven liquid crystal (ELC) lens with tunable focal length and their depth of field has been extensively applied in 3D display and imaging systems. In this work, a dual-layer electrode-driven liquid crystal (DELC) lens with electrically tunable focal length and controllable focal plane is demonstrated. ITO-SiO2-AZO electrodes with the dual-layer staggered structure on the top substrate are used as driven electrodes within a LC cell, which permits the establishment of an alternative controllability. The focal length of the DELC lens can be adjusted from 1.41 cm to 0.29 cm when the operating voltage changes from 15 V to 40 V. Furthermore, the focal plane of the DELC lens can selectively move by changing the driving method of the applied voltage to the next driven electrodes. This work demonstrates that the DELC lens has potential applications in imaging systems because of electrically tunable focal length and controllable focal plane.

  11. Optimization of confocal laser induced fluorescence for long focal length applications

    Science.gov (United States)

    Jemiolo, Andrew J.; Henriquez, Miguel F.; Thompson, Derek S.; Scime, Earl E.

    2017-10-01

    Laser induced fluorescence (LIF) is a non-perturbative diagnostic for measuring ion and neutral particle velocities and temperatures in a plasma. The conventional method for single-photon LIF requires intersecting optical paths for light injection and collection. The multiple vacuum windows needed for such measurements are unavailable in many plasma experiments. Confocal LIF eliminates the need for perpendicular intersecting optical paths by using concentric injection and collection paths through a single window. One of the main challenges with using confocal LIF is achieving high resolution measurements at the longer focal lengths needed for many plasma experiments. We present confocal LIF measurements in HELIX, a helicon plasma experiment at West Virginia University, demonstrating spatial resolution dependence on focal length and spatial filtering. By combining aberration mitigating optics with spatial filtering, our results show high resolution measurements at focal lengths of 0.5 m, long enough to access the interiors of many laboratory plasma experiments. This work was supported by U.S. National Science Foundation Grant No. PHY-1360278.

  12. Measuring microfocus focal spots using digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Fry, David A [Los Alamos National Laboratory

    2009-01-01

    Measurement of microfocus spot size can be important for several reasons: (1) Quality assurance during manufacture of microfocus tubes; (2) Tracking performance and stability of microfocus tubes; (3) Determining magnification (especially important for digital radiography where the native spatial resolution of the digital system is not adequate for the application); (4) Knowledge of unsharpness from the focal spot alone. The European Standard EN 12543-5 is based on a simple geometrical method of calculating focal spot size from unsharpness of high magnification film radiographs. When determining microfocus focal spot dimensions using unsharpness measurements both signal-to-noise (SNR) and magnification can be important. There is a maximum accuracy that is a function of SNR and therefore an optimal magnification. Greater than optimal magnification can be used but it will not increase accuracy.

  13. THERMAL EFFECTS ON CAMERA FOCAL LENGTH IN MESSENGER STAR CALIBRATION AND ORBITAL IMAGING

    Directory of Open Access Journals (Sweden)

    S. Burmeister

    2018-04-01

    Full Text Available We analyse images taken by the MErcury Surface, Space ENviorment, GEochemistry, and Ranging (MESSENGER spacecraft for the camera’s thermal response in the harsh thermal environment near Mercury. Specifically, we study thermally induced variations in focal length of the Mercury Dual Imaging System (MDIS. Within the several hundreds of images of star fields, the Wide Angle Camera (WAC typically captures up to 250 stars in one frame of the panchromatic channel. We measure star positions and relate these to the known star coordinates taken from the Tycho-2 catalogue. We solve for camera pointing, the focal length parameter and two non-symmetrical distortion parameters for each image. Using data from the temperature sensors on the camera focal plane we model a linear focal length function in the form of f(T = A0 + A1 T. Next, we use images from MESSENGER’s orbital mapping mission. We deal with large image blocks, typically used for the production of a high-resolution digital terrain models (DTM. We analyzed images from the combined quadrangles H03 and H07, a selected region, covered by approx. 10,600 images, in which we identified about 83,900 tiepoints. Using bundle block adjustments, we solved for the unknown coordinates of the control points, the pointing of the camera – as well as the camera’s focal length. We then fit the above linear function with respect to the focal plane temperature. As a result, we find a complex response of the camera to thermal conditions of the spacecraft. To first order, we see a linear increase by approx. 0.0107 mm per degree temperature for the Narrow-Angle Camera (NAC. This is in agreement with the observed thermal response seen in images of the panchromatic channel of the WAC. Unfortunately, further comparisons of results from the two methods, both of which use different portions of the available image data, are limited. If leaving uncorrected, these effects may pose significant difficulties in

  14. The Modernization of a Long-Focal Length Fringe-Type Laser Velocimeter

    Science.gov (United States)

    Meyers, James F.; Lee, Joseph W.; Cavone, Angelo A.; Fletcher, Mark T.

    2012-01-01

    A long-focal length laser velocimeter constructed in the early 1980's was upgraded using current technology to improve usability, reliability and future serviceability. The original, free-space optics were replaced with a state-of-the-art fiber-optic subsystem which allowed most of the optics, including the laser, to be remote from the harsh tunnel environment. General purpose high-speed digitizers were incorporated in a standard modular data acquisition system, along with custom signal processing software executed on a desktop computer, served as the replacement for the signal processors. The resulting system increased optical sensitivity with real-time signal/data processing that produced measurement precisions exceeding those of the original system. Monte Carlo simulations, along with laboratory and wind tunnel investigations were used to determine system characteristics and measurement precision.

  15. Overview of bunch length measurements

    International Nuclear Information System (INIS)

    Lumpkin, A. H.

    1999-01-01

    An overview of particle and photon beam bunch length measurements is presented in the context of free-electron laser (FEL) challenges. Particle-beam peak current is a critical factor in obtaining adequate FEL gain for both oscillators and self-amplified spontaneous emission (SASE) devices. Since measurement of charge is a standard measurement, the bunch length becomes the key issue for ultrashort bunches. Both time-domain and frequency-domain techniques are presented in the context of using electromagnetic radiation over eight orders of magnitude in wavelength. In addition, the measurement of microbunching in a micropulse is addressed

  16. CEBAF Upgrade Bunch Length Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, Mahmoud [Old Dominion Univ., Norfolk, VA (United States)

    2016-05-01

    Many accelerators use short electron bunches and measuring the bunch length is important for efficient operations. CEBAF needs a suitable bunch length because bunches that are too long will result in beam interruption to the halls due to excessive energy spread and beam loss. In this work, bunch length is measured by invasive and non-invasive techniques at different beam energies. Two new measurement techniques have been commissioned; a harmonic cavity showed good results compared to expectations from simulation, and a real time interferometer is commissioned and first checkouts were performed. Three other techniques were used for measurements and comparison purposes without modifying the old procedures. Two of them can be used when the beam is not compressed longitudinally while the other one, the synchrotron light monitor, can be used with compressed or uncompressed beam.

  17. Design of a nanopatterned long focal-length planar focusing collector for concentrated solar power

    Science.gov (United States)

    Ding, Qing; Choubal, Aakash; Toussaint, Kimani C.

    2017-02-01

    Concentrated solar power (CSP) facilities heavily utilize parabolic troughs to collect and concentrate sunlight onto receivers that deliver solar thermal energy to heat engines for generating electricity. However, parabolic troughs are bulky and heavy and result in a large capital investment for CSP plants, thereby making it difficult for CSP technology to be competitive with photovoltaics. We present the design of a planar focusing collector (PFC) with focal length beyond the micron scale. The PFC design is based on the use of a nanostructured silver surface for linearly polarized singlewavelength light. The designed PFC consists of metallic nanogrooves on a dielectric substrate. The geometric properties, namely the width and depth, of a single-unit nanogroove allows for full control of the optical phase at desired spatial coordinates along the nanogroove short-axis for a single wavelength. Moreover, we show numerically that such phase control can be used to construct a phase front that mimics that of a cylindrical lens. In addition, we determine the concentration ratio by comparing the width of our PFC design to the cross-sectional width of its focal spot. We also determine the conversion efficiency at long focal lengths by evaluating the ratio of the collected optical power to the incoming optical power. Finally, we examine the focusing behavior across multiple wavelengths and angles of incidence. Our work shows how nano-optics and plasmonics could contribute to this important area of CSP technology.

  18. High-Performance PVC Gel for Adaptive Micro-Lenses with Variable Focal Length.

    Science.gov (United States)

    Bae, Jin Woo; Shin, Eun-Jae; Jeong, Jaeu; Choi, Dong-Soo; Lee, Jong Eun; Nam, Byeong Uk; Lin, Liwei; Kim, Sang-Youn

    2017-05-18

    This paper presents a bio-inspired adaptive micro-lens with electrically tunable focus made of non-ionic high-molecular-weight polyvinyl chloride (PVC) gel. The optical device mimics the design of the crystalline lens and ciliary muscle of the human eye. It consists of a plano-convex PVC gel micro-lens on Indium Tin Oxide (ITO) glass, confined with an annular electrode operating as an artificial ciliary muscle. Upon electrical activation, the electroactive adhesive force of the PVC gel is exerted on the annular anode electrode, which reduces the sagittal height of the plano-convex PVC gel lens, resulting in focal length variation of the micro-lens. The focal length increases from 3.8 mm to 22.3 mm as the applied field is varied from 200 V/mm to 800 V/mm, comparable to that of the human lens. The device combines excellent optical characteristics with structural simplicity, fast response speed, silent operation, and low power consumption. The results show the PVC gel micro-lens is expected to open up new perspectives on practical tunable optics.

  19. Laser Beam Caustic Measurement with Focal Spot Analyser

    DEFF Research Database (Denmark)

    Olsen, Flemming Ove; Gong, Hui; Bagger, Claus

    2005-01-01

    In industrial applications of high power CO2-lasers the caustic characteristics of the laser beam have great effects on the performance of the lasers. A welldefined high intense focused spot is essential for reliable production results. This paper presents a focal spot analyser that is developed...... for measuring the beam profiles of focused high power CO2-lasers....

  20. Modeling of a Variable Focal Length Flat Lens Using Left Handed Metamaterials

    Science.gov (United States)

    Reinert, Jason

    2004-01-01

    Left Handed Metamaterials (LHM) were originally purposed by Victor Veselago in1968. These substances would allow a flat structure to focus electromagnetic (EM) waves because they have a negative index of refraction. A similar structure made from conventional materials, those with a positive index of refraction, would disperse the waves. But until recently, these structures have been purely theoretical because substances with both a negative permittivity and negative permeability, material properties necessary for a negative index of refraction, do not naturally exist, Recent developments have produced a structure composed of an array of thin wires and split ring resonators that shows a negative index of refraction. area smaller than a square wavelength. How small the area is can be determined by how perfectly the lens is polished and how pure the substance is that composes the lens. These lenses must also be curved for focusing to occur. The focal length is determined by the curvature of the lens and the material. On the other hand, a flat structure made from LHM would focus light because of the effect of a negative index of refraction in Snell s law. The focal length could also be varied by simply adjusting the distance of the lens from the source of radiation. This could create many devices that are adjustable to different situations in fields such as biomedical imaging and communication. the software package XFDTD which solves Maxwell s equations in the frequency domain as well as the time domain. The program used Drude models of materials to simulate the effect of negative permittivity and negative permeability. Because of this, a LHM can be simulated as a solid block of material instead of an array of wires and split ring resonators. After a flat lens is formed, I am to examine the focusing effect of the lens and determine if a higher resolution flat lens can be developed. Traditional lenses made from conventional materials cannot focus an EM wave onto an My

  1. Martian Length of Day Measurements from Rovers

    Science.gov (United States)

    Eubanks, T. M.; Bills, B.

    2012-06-01

    Changes in the Martian Length of Day (LOD) can be determined at a scientifically use level by a combination of regular (but not necessarily frequent) range and Doppler measurements from Earth and dead reckoning in a Kalman filter.

  2. Bunch Length Measurements in SPEAR3

    Energy Technology Data Exchange (ETDEWEB)

    Corbett, W.J.; Fisher, A.; Huang, X.; Safranek, J.; Sebek, J.; /SLAC; Lumpkin, A.; /Argonne; Sannibale, F.; /LBL, Berkeley; Mok, W.; /Unlisted

    2007-11-28

    A series of bunch length measurements were made in SPEAR3 for two different machine optics. In the achromatic optics the bunch length increases from the low-current value of 16.6ps rms to about 30ps at 25ma/bunch yielding an inductive impedance of -0.17{Omega}. Reducing the momentum compaction factor by a factor of {approx}60 [1] yields a low-current bunch length of {approx}4ps rms. In this paper we review the experimental setup and results.

  3. Distance and Cable Length Measurement System

    Science.gov (United States)

    Hernández, Sergio Elias; Acosta, Leopoldo; Toledo, Jonay

    2009-01-01

    A simple, economic and successful design for distance and cable length detection is presented. The measurement system is based on the continuous repetition of a pulse that endlessly travels along the distance to be detected. There is a pulse repeater at both ends of the distance or cable to be measured. The endless repetition of the pulse generates a frequency that varies almost inversely with the distance to be measured. The resolution and distance or cable length range could be adjusted by varying the repetition time delay introduced at both ends and the measurement time. With this design a distance can be measured with centimeter resolution using electronic system with microsecond resolution, simplifying classical time of flight designs which require electronics with picosecond resolution. This design was also applied to position measurement. PMID:22303169

  4. Stride length: measuring its instantaneous value

    International Nuclear Information System (INIS)

    Campiglio, G C; Mazzeo, J R

    2007-01-01

    Human gait has been studied from different viewpoints: kinematics, dynamics, sensibility and others. Many of its characteristics still remain open to research, both for normal gait and for pathological gait. Objective measures of some of its most significant spatial/temporal parameters are important in this context. Stride length, one of these parameters, is defined as the distance between two consecutive contacts of one foot with ground. On this work we present a device designed to provide automatic measures of stride length. Its features make it particularly appropriate for the evaluation of pathological gait

  5. Measuring the orbit length of the Tevatron

    International Nuclear Information System (INIS)

    Kerns, C.; Kerns, Q.; Miller, H.

    1985-06-01

    The orbit length in the Tevatron was measured when coasting beam was first obtained. The method was time-of-flight, using a vernier phase comparison between beam pickup signals and a synthesizer sine wave. Some effort was spent making a stable phase detector so that it would not be a limiting factor. The results exhibited a repeatability of a few Hz at 53 MHz, corresponding to a mean radius measurement to 0.1 mm. 5 refs., 4 figs

  6. Measure it! fun with length and distance

    CERN Document Server

    First, Rachel

    2016-01-01

    Make math fun with Measure It! Fun photographs, colorful graphics, and simple text are used to teach young readers basic math concepts. From Metric System to Standard System this book will help kids develop the skills they need. A simple activity at the end of the book encourages kids to put length and distance to use! Aligned to Common Core standards and correlated to state standards. Sandcastle is an imprint of Abdo Publishing, a division of ABDO.

  7. Smith Purcell Radiation Bunch-Length Measurement

    CERN Document Server

    Korbly, Stephen; Marsh, Roark A; Temkin, Richard J

    2005-01-01

    Measurements of Coherent Smith-Purcell Radiation (SPR) were performed at the 17 GHz high-gradient accelerator built by Haimson Research Corporation at the MIT Plasma Science and Fusion Center. SPR is a promising radiation source because the radiation intensity is enhanced by the number of grating periods. The radiation produced obeys the SP resonance condition correlating the radiation frequency at each observation angle, allowing SPR to be exploited as a bunch-length measurement. For a 15 MeV 150 mA 125 ns beam in short and long pulse modes, bunch-lengths of 0.6 ps and 1 ps were measured with this method, respectively, with an error of ± 0.1 ps. Frequency measurements were also performed using a double Heterodyne system. Heterodyne measurements revealed frequency-locking, which gave a power level enhancement of 1000 at integer multiples of the Accelerator RF frequency. Frequencies up to 514 GHz were measured with a bandwidth of 25 MHz.

  8. Bunch Length Measurements using Coherent Radiation

    CERN Document Server

    Ischebeck, Rasmus; Barnes, Christopher; Blumenfeld, Ian; Clayton, Chris; Decker, Franz Josef; Deng, Suzhi; Hogan, Mark; Huang Cheng Kun; Iverson, Richard; Johnson, Devon K; Krejcik, Patrick; Lu, Wei; Marsh, Kenneth; Oz, Erdem; Siemann, Robert; Walz, Dieter

    2005-01-01

    The accelerating field that can be obtained in a beam-driven plasma wakefield accelerator depends on the current of the electron beam that excites the wake. In the E-167 experiment, a peak current above 10kA will be delivered at a particle energy of 28GeV. The bunch has a length of a few ten micrometers and several methods are used to measure its longitudinal profile. Among these, autocorrelation of coherent transition radiation (CTR) is employed. The beam passes a thin metallic foil, where it emits transition radiation. For wavelengths greater than the bunch length, this transition radiation is emitted coherently. This amplifies the long-wavelength part of the spectrum. A scanning Michelson interferometer is used to autocorrelate the CTR. However, this method requires the contribution of many bunches to build an autocorrelation trace. The measurement is influenced by the transmission characteristics of the vacuum window and beam splitter. We present here an analysis of materials, as well as possible layouts ...

  9. Measurements of plasma mirror reflectivity and focal spot quality for tens of picosecond laser pulses

    Science.gov (United States)

    Forestier-Colleoni, Pierre; Williams, Jackson; Scott, Graeme; Mariscal, Dereck. A.; McGuffey, Christopher; Beg, Farhat N.; Chen, Hui; Neely, David; Ma, Tammy

    2017-10-01

    The Advanced Radiographic Capability (ARC) laser at the NIF (LLNL) is high-energy ( 4 kJ) with a pulse length of 30ps, and is capable of focusing to an intensity of 1018W/cm2 with a 100 μm focal spot. The ARC laser is at an intensity which can be used to produce proton beams. However, for applications such as radiography and warm dense matter creation, a higher laser intensity may be desired to generate more energetic proton beams. One possibility to increase the intensity is to decrease the focused spot size by employing a smaller f-number optic. But it is difficult to implement such an optic or to bring the final focusing parabola closer to the target within the complicated NIF chamber geometry. A proposal is to use ellipsoidal plasma mirrors (PM) for fast focusing of the ARC laser light, thereby increasing the peak intensity. There is uncertainty, however, in the survivability and reflectivity of PM at such long pulse durations. Here, we show experimental results from the Titan laser to study the reflectivity of flat PM as a function of laser pulse length. A calorimeter was used to measure the PM reflectivity. We also observed degradation of the far and near field energy distribution of the laser after the reflection by the PM for pulse-lengths beyond 10ps. Contract DE-AC52-07NA27344. Funded by the LLNL LDRD program: tracking code 17-ERD-039.

  10. Automated body hair counting and length measurement.

    Science.gov (United States)

    Vallotton, P; Thomas, N

    2008-11-01

    Hair loss or hair excess is a common condition. There is a growing need to quantitatively assess the success of interventions aimed at replenishing areas that lack hair or at removing hair from areas such as the back, the legs, or the arms. Non-invasive methods that do not require staining are highly desirable because the staining process itself may affect the efficacy of the treatment. We introduce a system based on a flatbed scanner and on novel and sensitive image analysis algorithms to count the number of hairs and their individual length. Additionally, a measure of hair visibility is introduced, which allows assessing objectively the severity of the condition. Our system is able to detect even hairs that are difficult to see to a human observer. It is robust to skin impurities or variations in the skin texture and colour. Scanner imaging ensures a sharp image over the whole field. The system analyses on the order of two images per minute, making it suitable for large clinical studies. Counts delivered by a human counter vs. the software were within 10% of each other (N=12). Based on our results, we expect that the software will be useful to a number of researchers investigating medical and cosmetic issues involving objective assessment of pilosity. The algorithm itself may be of use for other applications.

  11. Automated path length and M56 measurements at Jefferson Lab

    International Nuclear Information System (INIS)

    Hardy, D.; Tang, J.; Legg, R.

    1997-01-01

    Accurate measurement of path length and path length changes versus momentum (M 56 ) are critical for maintaining minimum beam energy spread in the CEBAF (Continuous Electron Beam Accelerator Facility) accelerator at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). The relative path length for each circuit of the beam (1256m) must be equal within 1.5 degrees of 1497 MHz RF phase. A relative path length measurement is made by measuring the relative phases of RF signals from a cavity that is separately excited for each pass of a 4.2 μs pulsed beam. This method distinguishes the path length to less than 0.5 path length error. The development of a VME based automated measurement system for path length and M 56 has contributed to faster machine setup time and has the potential for use as a feedback parameter for automated control

  12. Validation of Navigation Ultrasound for Clavicular Length Measurement

    DEFF Research Database (Denmark)

    Høj, Anders Thorsmark; Villa, Chiara; Christensen, Ole M

    2017-01-01

    ultrasound, to deliver accurate measurements seems promising. To examine the reliability and validity of navigation ultrasound for length measurements of the clavicle, a study was performed using length measurements performed before forensic autopsies from 2012 to 2013. In total, 38 bodies with a median age...

  13. Cervical length measurement: comparison of transabdominal and transvaginal approach

    DEFF Research Database (Denmark)

    Westerway, Sue C; Pedersen, Lars Henning; Hyett, Jon

    2015-01-01

    plots showed an inverse trend with shorter cervixes. In women with a cervix TV scan measurement, TA overestimated cervical length by 12 mm (P ... accurately, particularly if the cervix is short. At 24–34 weeks, a policy of proceeding to TV scan if TA measurement is women attending with symptoms and signs......Objective: To compare transabdominal (TA) and transvaginal (TV) ultrasound assessment of cervical length at 16-41 weeks gestation. Methods: TA and TV ultrasound measurements of cervical length were made on 491 pregnancies of 16-41 weeks gestation. Cervical length was measured from internal...

  14. Value of endometrial thickness measurement for diagnosing focal intrauterine pathology in women without abnormal uterine bleeding

    DEFF Research Database (Denmark)

    Dreisler, E; Sorensen, S Stampe; Ibsen, P H

    2009-01-01

    OBJECTIVE: To assess the diagnostic value of transvaginal sonographic (TVS) measurement of endometrial thickness for diagnosing focal intrauterine pathology in women without abnormal uterine bleeding (AUB). METHODS: A random selection from the Danish Civil Registration System was made: 1660 women...... aged 20-74 years were invited to participate and 686 women were eligible and accepted inclusion (429 pre- and 257 postmenopausal). The women underwent TVS measurement of endometrial thickness and saline contrast sonohysterography (SCSH). Hysteroscopic resection with histopathology (gold standard...... modulators (n = 2). Thus, 375 women without AUB were included (217 pre- and 158 postmenopausal). Receiver-operating characteristics (ROC) curves for endometrial thickness and focal lesion were analyzed. RESULTS: Focal intrauterine pathology was confirmed in 41 women (35 with polyps, five with submucosal...

  15. Tropicalized Lambda Lengths, Measured Laminations and Convexity

    DEFF Research Database (Denmark)

    C. Penner, R.

    of the basic cell decomposition of Riemann's moduli space to other contexts for general moduli spaces of flat connections on a surface. In any case, this discussion drastically simplifies aspects of previous related studies as is explained. Furthermore, a new class of measured laminations relative to an ideal...

  16. Bunch length measurement using coherent Cherenkov radiation

    International Nuclear Information System (INIS)

    Kan, K.; Yang, J.; Ogata, A.; Kondoh, T.; Norizawa, K.; Yoshida, Y.

    2011-01-01

    A new method for bunch diagnostic based on multimode Coherent Cherenkov Radiation (CCR) was proposed. Generation of quasi-monochromatic terahertz (THz) using multimode CCR on the order of 0.1 THz was carried out. The intensity and frequency of CCR were measured directly by a Michelson interferometer and a bolometer. (author)

  17. Measuring the Flatness of Focal Plane for Very Large Mosaic CCD Camera

    Energy Technology Data Exchange (ETDEWEB)

    Hao, Jiangang; Estrada, Juan; Cease, Herman; Diehl, H.Thomas; Flaugher, Brenna L.; Kubik, Donna; Kuk, Keivin; Kuropatkine, Nickolai; Lin, Huan; Montes, Jorge; Scarpine, Vic; /Fermilab

    2010-06-08

    Large mosaic multiCCD camera is the key instrument for modern digital sky survey. DECam is an extremely red sensitive 520 Megapixel camera designed for the incoming Dark Energy Survey (DES). It is consist of sixty two 4k x 2k and twelve 2k x 2k 250-micron thick fully-depleted CCDs, with a focal plane of 44 cm in diameter and a field of view of 2.2 square degree. It will be attached to the Blanco 4-meter telescope at CTIO. The DES will cover 5000 square-degrees of the southern galactic cap in 5 color bands (g, r, i, z, Y) in 5 years starting from 2011. To achieve the science goal of constraining the Dark Energy evolution, stringent requirements are laid down for the design of DECam. Among them, the flatness of the focal plane needs to be controlled within a 60-micron envelope in order to achieve the specified PSF variation limit. It is very challenging to measure the flatness of the focal plane to such precision when it is placed in a high vacuum dewar at 173 K. We developed two image based techniques to measure the flatness of the focal plane. By imaging a regular grid of dots on the focal plane, the CCD offset along the optical axis is converted to the variation the grid spacings at different positions on the focal plane. After extracting the patterns and comparing the change in spacings, we can measure the flatness to high precision. In method 1, the regular dots are kept in high sub micron precision and cover the whole focal plane. In method 2, no high precision for the grid is required. Instead, we use a precise XY stage moves the pattern across the whole focal plane and comparing the variations of the spacing when it is imaged by different CCDs. Simulation and real measurements show that the two methods work very well for our purpose, and are in good agreement with the direct optical measurements.

  18. FoCal – A high granularity electromagnetic calorimeter for forward direct photon measurements

    NARCIS (Netherlands)

    Zhang, C.

    2017-01-01

    The measurement of direct photon production at forward rapidity (y∼3−5) at the LHC provides access to the structure of protons and nuclei at very small values of fractional momentum (x∼10−5). FoCal, an extremely-high-granularity Forward Calorimeter covering 3.3<η<5.3 is proposed as a detector

  19. Real-time single-shot electron bunch length measurements

    CERN Document Server

    Wilke, I; Gillespie, W A; Berden, G; Knippels, G M H; Meer, A F G

    2002-01-01

    Linear accelerators employed as drivers for X-ray free electron lasers (FELs) require relativistic electron bunch with sub-picosecond bunch length. Precise bunch length measurements are important for the tuning and operation of the FELs. Previously, we have demonstrated that electro-optic detection is a powerful technique for sub-picosecond electron bunch length measurements. In those experiments, the measured bunch length was the average of all electron bunches within a macropulse. Here, for the first time, we present the measurement of the length of individual electron bunches using a development of our previous technique. In this experiment, the longitudinal electron bunch shape is encoded electro-optically on to the frequency spectrum of a chirped laser pulse. Subsequently, the laser pulse is dispersed by a grating and the spectrum is imaged with a CCD camera. Single bunch measurements are achieved by using a nanosecond gated camera, and synchronizing the gate with both the electron bunch and the laser pu...

  20. From Concrete to Abstract in the Measurement of Length

    International Nuclear Information System (INIS)

    Stephanou, Andreas; Fisher, William P Jr

    2013-01-01

    The concatenation of units of length is widely viewed as the paradigmatic expression of fundamental measurement. Survey, assessment, and test scores in educational and psychological measurement are often interpreted in ways that assume a concatenation of units to have been established, even though these assumptions are rarely stated or tested. A concatenation model for measurement is shown to be equivalent to a Rasch model: any two units of measurement placed end to end must together be of the same length as either one of them added to itself. This additive principle and a concatenation model of measurement together serve as a heuristic guide for organizing two experimental approaches to calibrating instruments for measuring length. The capacity to reproduce the unit of measurement from theory with no need for repeated empirical calibration experiments, as in the geometrical bisection of the line and the resultant halving of the length measure, is highlighted as essential to demonstrating a thorough understanding of the construct

  1. Bunch length measurements in the SLC damping ring

    International Nuclear Information System (INIS)

    Decker, F.J.; Limberg, T.; Minty, M.; Ross, M.

    1993-05-01

    The synchrotron light of the SLC damping ring was used to measure the bunch length with a streak camera at different times in the damping cycle. There are bunch length oscillations after injection, different equilibrium length during the cycle due to rf manipulations to avoid microwave instability oscillations, and just before extraction there is a longitudinal phase space rotation (bunch muncher) to shorten the bunch length. Measurements under these different conditions are presented and compared with BPM pulse height signals. Calibration and adjustment issues and the connection of the streak camera to the SLC control system are also discussed

  2. Validation of a novel ultrasound measurement of achilles tendon length

    DEFF Research Database (Denmark)

    Barfod, Kristoffer Weisskirchner; Riecke, Anja Falk; Boesen, Anders

    2014-01-01

    PURPOSE: A clinically applicable and accurate method for measuring Achilles tendon length is needed to investigate the influence of elongation of the Achilles tendon after acute rupture. The purpose of this study was to develop and validate an ultrasonographic (US) length measurement...... of the Achilles tendon-aponeurosis complex. METHODS: Both legs of 19 non-injured subjects were examined by magnetic resonance imaging (MRI) and US. The length from calcaneus to the medial head of m. Gastrocnemius was measured by three independent US examiners. Repeated US measurements were performed and compared...... to be further assessed in the setting of acute Achilles tendon rupture. CLINICAL RELEVANCE: This new ultrasound measurement might allow for length measurement of ruptured Achilles tendons in the acute and chronic state after rupture. LEVEL OF EVIDENCE: II....

  3. Validity of plant fiber length measurement : a review of fiber length measurement based on kenaf as a model

    Science.gov (United States)

    James S. Han; Theodore. Mianowski; Yi-yu. Lin

    1999-01-01

    The efficacy of fiber length measurement techniques such as digitizing, the Kajaani procedure, and NIH Image are compared in order to determine the optimal tool. Kenaf bast fibers, aspen, and red pine fibers were collected from different anatomical parts, and the fiber lengths were compared using various analytical tools. A statistical analysis on the validity of the...

  4. [Comparison between the tooth length measured by cone-beam CT and the tooth length measured with vernier caliper].

    Science.gov (United States)

    Yang, Yi-qiang; Mi, Zhen-lin; Ge, Zhen-lin

    2013-11-01

    To evaluate the accuracy of cone-bean CT (CBCT) on the measurement of the tooth length. One hundred and sixty single root premolars extracted for orthodontic purposes were selected. The tooth length was measured with vernier caliper. The premolars were divided into 10 groups randomly, 16 premolars in each group.In each group, the teeth were lined in molar area, premolar area, canine area and anterior tooth area in maxilla and mandible. Then CBCT was taken, and the tooth length was measured using the software supplied by the manufacturer in coronal and sagittal plane. Accuracy was compared between vernier caliper measurement and CBCT measurement. The tooth length measured by CBCT was smaller than that measured with the vernier caliper. Significant differences were found in six areas, except the maxillary and mandibular premolar areas. With the increase of mesial-distal inclination or buccolingual torque angle, the difference between tooth length measured by CBCT and that measured with vernier caliper increased. The correlation between buccolingual torque angle (∠X1) and the coronal view of CBCT radiology tooth length (Spearmen index was 7.00, P caliper.

  5. Measurement of endodontic file lengths: calibrated versus uncalibrated digital images.

    Science.gov (United States)

    Loushine, R J; Weller, R N; Kimbrough, W F; Potter, B J

    2001-12-01

    This in vitro study compared the accuracy of file length measurements made on calibrated and uncalibrated direct digital images. Endodontic files of known lengths and ISO sizes were used in 10 single-rooted, relatively straight teeth within cadaver specimens. The crowns of the teeth were ground flat and an orthodontic wire of known length was secured to the coronal surface. This wire was placed mesiodistally and perpendicular to the root and served as the reference point for the file measurement and as a calibration reference length. A #20 file was hand-measured to a length that reached the apical third of each tooth. It was inserted and a radiographic image was secured. The instrument was remeasured three additional times at different lengths on the same tooth and reinserted before each image acquisition. Thus 40 digital images were acquired using a GE X-ray unit and a Schick Computed Dental Radiography (CDR) #2 sensor. These images were placed in random order, and an independent, blinded investigator determined the file lengths using on-screen calibrated and uncalibrated measurement of the CDR image with a straight-line and multiple-line measuring technique. The experimental measurements were compared with each other and with the known clinical measurements. A two-way analysis of variance indicated that there was a statistically significant difference showing that the calibrated measurements were more accurate than the uncalibrated measurements (p = 0.0001), and there was no significant difference between the straight-line and multiple-line measuring techniques (p = 0.14).

  6. Accurate acoustic power measurement for low-intensity focused ultrasound using focal axial vibration velocity

    Science.gov (United States)

    Tao, Chenyang; Guo, Gepu; Ma, Qingyu; Tu, Juan; Zhang, Dong; Hu, Jimin

    2017-07-01

    Low-intensity focused ultrasound is a form of therapy that can have reversible acoustothermal effects on biological tissue, depending on the exposure parameters. The acoustic power (AP) should be chosen with caution for the sake of safety. To recover the energy of counteracted radial vibrations at the focal point, an accurate AP measurement method using the focal axial vibration velocity (FAVV) is proposed in explicit formulae and is demonstrated experimentally using a laser vibrometer. The experimental APs for two transducers agree well with theoretical calculations and numerical simulations, showing that AP is proportional to the square of the FAVV, with a fixed power gain determined by the physical parameters of the transducers. The favorable results suggest that the FAVV can be used as a valuable parameter for non-contact AP measurement, providing a new strategy for accurate power control for low-intensity focused ultrasound in biomedical engineering.

  7. In vivo myograph measurement of muscle contraction at optimal length

    Directory of Open Access Journals (Sweden)

    Ahmed Aminul

    2007-01-01

    Full Text Available Abstract Background Current devices for measuring muscle contraction in vivo have limited accuracy in establishing and re-establishing the optimum muscle length. They are variable in the reproducibility to determine the muscle contraction at this length, and often do not maintain precise conditions during the examination. Consequently, for clinical testing only semi-quantitative methods have been used. Methods We present a newly developed myograph, an accurate measuring device for muscle contraction, consisting of three elements. Firstly, an element for adjusting the axle of the device and the physiological axis of muscle contraction; secondly, an element to accurately position and reposition the extremity of the muscle; and thirdly, an element for the progressive pre-stretching and isometric locking of the target muscle. Thus it is possible to examine individual in vivo muscles in every pre-stretched, specified position, to maintain constant muscle-length conditions, and to accurately re-establish the conditions of the measurement process at later sessions. Results In a sequence of experiments the force of contraction of the muscle at differing stretching lengths were recorded and the forces determined. The optimum muscle length for maximal force of contraction was established. In a following sequence of experiments with smaller graduations around this optimal stretching length an increasingly accurate optimum muscle length for maximal force of contraction was determined. This optimum length was also accurately re-established at later sessions. Conclusion We have introduced a new technical solution for valid, reproducible in vivo force measurements on every possible point of the stretching curve. Thus it should be possible to study the muscle contraction in vivo to the same level of accuracy as is achieved in tests with in vitro organ preparations.

  8. Value of apparent diffusion coefficient measurement for discrimination of focal benign and malignant hepatic masses.

    Science.gov (United States)

    Kilickesmez, O; Bayramoglu, S; Inci, E; Cimilli, T

    2009-02-01

    The purpose of our study was to investigate the value of diffusion-weighted magnetic resonance imaging (DW-MRI) to discriminate benign and malignant focal lesions of the liver using parallel imaging technique. A total of 77 patients and 65 healthy controls were enrolled in the study. DW-MRI was performed with b-factors of 0, 500 and 1000 s/mm(2), and the apparent diffusion coefficients (ADC) values of the normal liver and the lesions were calculated. The mean ADC value of the focal liver lesions were as follows: simple cysts (3.16 +/- 0.18 x 10(-3) mm(2)/s), hydatid cysts (2.58 +/- 0.53 x 10(-3) mm(2)/s), hemangiomas (1.97 +/- 0.49 x 10(-3) mm(2)/s), metastases (1.14 +/- 0.41 x 10(-3) mm(2)/s) and hepatocellular carcinomas (HCC) (1.15 +/- 0.36 x 10(-3) mm(2)/s). The mean ADC values of all the disease groups were statistically significant when compared with the mean ADC value of the normal liver (1.56 +/- 0.14 x 10(-3) mm(2)/s), (P values of hemangiomas and HCC metastases (P present study showed that ADC measurement has the potential to differentiate benign and malignant focal hepatic lesions. We propose to add DW sequence in the MR protocol for the detection and quantitative discrimination of hepatic pathologies.

  9. The impact of precise robotic lesion length measurement on stent length selection: ramifications for stent savings.

    Science.gov (United States)

    Campbell, Paul T; Kruse, Kevin R; Kroll, Christopher R; Patterson, Janet Y; Esposito, Michele J

    2015-09-01

    Coronary stent deployment outcomes can be negatively impacted by inaccurate lesion measurement and inappropriate stent length selection (SLS). We compared visual estimate of these parameters to those provided by the CorPath 200® Robotic PCI System. Sixty consecutive patients who underwent coronary stent placement utilizing the CorPath System were evaluated. The treating physician assessed orthogonal images and provided visual estimates of lesion length and SLS. The robotic system was then used for the same measures. SLS was considered to be accurate when visual estimate and robotic measures were in agreement. Visual estimate SLSs were considered to be "short" or "long" if they were below or above the robotic-selected stents, respectively. Only 35% (21/60) of visually estimated lesions resulted in accurate SLS, whereas 33% (20/60) and 32% (19/60) of the visually estimated SLSs were long and short, respectively. In 5 cases (8.3%), 1 less stent was placed based on the robotic lesion measurement being shorter than the visual estimate. Visual estimate assessment of lesion length and SLS is highly variable with 65% of the cases being inaccurately measured when compared to objective measures obtained from the robotic system. The 32% of the cases where lesions were visually estimated to be short represents cases that often require the use of extra stents after the full lesion is not covered by 1 stent [longitudinal geographic miss (LGM)]. Further, these data showed that the use of the robotic system prevented the use of extra stents in 8.3% of the cases. Measurement of lesions with robotic PCI may reduce measurement errors, need for extra stents, and LGM. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Measurement, characterization, and modeling of noise in staring infrared focal plane arrays

    International Nuclear Information System (INIS)

    Scribner, D.A.; Kruer, M.R.; Gridley, C.J.; Sarkady, K.

    1987-01-01

    An account is given of selected methods for the measurement and characterization of spatial and temporal noise in staring focal plane arrays (FPAs), in order to demonstrate how these results can be used in simulations and analytic models to predict the performance of selected staring sensors. Attention is given to MIR FPAs applicable to the detection and tracking of point sources, and to the ways in which these spatial and temporal noise measurements can be incorporated into simulations and sensors having staring FPAs. Methods for predicting the performance of selected staring sensor systems are derivable from spatial and temporal noise values. 13 references

  11. Sonographic Measurement of Normal Splenic Length in Korean Adults

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Sang Bum; Cheon, Byung Kook; Kim, Jong Min; Oh, Kyung Seoung; Jung, Gyoo Sik; Huh, Jin Do; Joh, Young Duk [Kosin University College of Medicine, Busan (Korea, Republic of)

    1996-12-15

    To establish upper limit of normal splenic length of Korean adults on ultrasonography and to determice the degree of interobserver and intraobserver variation. Ultrasonographic scans were performed to measure the maximum length of spleen in 105 of 150 adults selected by convenience sampling. Remained 45 cases with any conditions that could alter splenic size were excluded from this study. The maximum length of spleen was measured and correlated with body surface area, patient height, weight, age and sex. In 31 of the 105 adults we evaluated the interobserver and intraobserver variations in sonographic measurements of splenic length obtained by three radiologists in blind fashion. The mean splenic length in 105 adults was 8.56cm ({+-} 0.95). The splenic length positively correlated with body surface area, patient height and weight (P <0.001), and negatively correlated with patient age (P < 0.01). Male spleen (8.87 cm {+-} 1.07) was longer than female spleen (8.35 cm {+-} 0.81) (P < 0.05). The following guidelines are proposed for the upper limit of normal splenic length at different groups of body surface area: no longer than 10 cm at 1.20{approx}1.59 m{sup 2}, 11 cm at1.60{approx}1.79 m{sup 2}, and 12 cm at 1.80{approx}1.99 m{sup 2}. The mean interobserver variation between any two radiologists ranged from 0.32 cm ({+-} 0.29) to 0.39 cm ({+-} 0.33) and interobserver variations were within 1 cm in 96%. The mean intraobserver variations were within 0.5 cm in 91%. The splenic length closely correlated with body surface area, patient height, weight and age. Particularly the upper limit of normal splenic length changed according to body surface area. Interobserver variation about 1 cm and intraobserver variation about 0.5 cm should be considered in the measurement of the splenic length on ultrasonography

  12. Electron bunch length measurement with a wakefield radiation decelerator

    Directory of Open Access Journals (Sweden)

    Weiwei Li

    2014-03-01

    Full Text Available In this paper, we propose a novel method to measure the electron bunch length with a dielectric wakefield radiation (DWR decelerator which is composed of two dielectric-lined waveguides (DLWs and an electron spectrometer. When an electron beam passes through a DLW, the DWR is excited which leads to an energy loss of the electron beam. The energy loss is found to be largely dependent on the electron bunch length and can be easily measured by an electron spectrometer which is essential for a normal accelerator facility. Our study shows that this method has a high resolution and a great simplicity.

  13. Measurement of the diffusion length of thermal neutrons inside graphite

    International Nuclear Information System (INIS)

    Ertaud, A.; Beauge, R.; Fauquez, H.; De Laboulay, H.; Mercier, C.; Vautrey, L.

    1948-11-01

    The diffusion length of thermal neutrons inside a given industrial graphite is determined by measuring the neutron density inside a parallelepipedal piling up of graphite bricks (2.10 x 2.10 x 2.442 m). A 3.8 curies (Ra α → Be) source is placed inside the parallelepipedal block of graphite and thin manganese detectors are used. Corrections are added to the unweighted measurements to take into account the effects of the damping of supra-thermal neutrons in the measurement area. These corrections are experimentally deduced from the differential measurements made with a cadmium screen interposed between the source and the first plane of measurement. An error analysis completes the report. The diffusion length obtained is: L = 45.7 cm ± 0.3. The average density of the graphite used is 1.76 and the average apparent density of the piling up is 1.71. (J.S.)

  14. Measuring Clearance Mechanics Based on Dynamic Leg Length

    Science.gov (United States)

    Khamis, Sam; Danino, Barry; Hayek, Shlomo; Carmeli, Eli

    2018-01-01

    The aim of this study was to quantify clearance mechanics during gait. Seventeen children diagnosed with hemiplegic cerebral palsy underwent a three-dimensional gait analysis evaluation. Dynamic leg lengths were measured from the hip joint center to the heel, to the ankle joint center and to the forefoot throughout the gait cycle. Significant…

  15. Measurement of surface crack length using image processing technology

    International Nuclear Information System (INIS)

    Nahm, Seung Hoon; Kim, Si Cheon; Kim, Yong Il; Ryu, Dae Hyun

    2001-01-01

    The development of a new experimental method is required to easily observe the growth behavior of fatigue cracks. To satisfy the requirement, an image processing technique was introduced to fatigue testing. The length of surface fatigue crack could be successfully measured by the image processing system. At first, the image data of cracks were stored into the computer while the cyclic loading was interrupted. After testing, crack length was determined using image processing software which was developed by ourselves. Block matching method was applied to the detection of surface fatigue cracks. By comparing the data measured by image processing system with the data measured by manual measurement with a microscope, the effectiveness of the image processing system was established. If the proposed method is used to monitor and observe the crack growth behavior automatically, the time and efforts for fatigue test could be dramatically reduced

  16. Multiscale multichroic focal planes for measurements of the cosmic microwave background

    Science.gov (United States)

    Cukierman, Ari; Lee, Adrian T.; Raum, Christopher; Suzuki, Aritoki; Westbrook, Benjamin

    2018-01-01

    We report on the development of multiscale multichroic focal planes for measurements of the cosmic microwave background (CMB). A multichroic focal plane, i.e., one that consists of pixels that are simultaneously sensitive in multiple frequency bands, is an efficient architecture for increasing the sensitivity of an experiment as well as for disentangling the contamination due to galactic foregrounds, which is increasingly becoming the limiting factor in extracting cosmological information from CMB measurements. To achieve these goals, it is necessary to observe across a broad frequency range spanning roughly 30-350 GHz. For this purpose, the Berkeley CMB group has been developing multichroic pixels consisting of planar superconducting sinuous antennas coupled to extended hemispherical lenslets, which operate at sub-Kelvin temperatures. The sinuous antennas, microwave circuitry and the transition-edge-sensor (TES) bolometers to which they are coupled are integrated in a single lithographed wafer.We describe the design, fabrication, testing and performance of multichroic pixels with bandwidths of 3:1 and 4:1 across the entire frequency range of interest. Additionally, we report on a demonstration of multiscale pixels, i.e., pixels whose effective size changes as a function of frequency. This property keeps the beam width approximately constant across all frequencies, which in turn allows the sensitivity of the experiment to be optimal in every frequency band. We achieve this by creating phased arrays from neighboring lenslet-coupled sinuous antennas, where the size of each phased array is chosen independently for each frequency band. We describe the microwave circuitry in detail as well as the benefits of a multiscale architecture, e.g., mitigation of beam non-idealities, reduced readout requirements, etc. Finally, we discuss the design and fabrication of the detector modules and focal-plane structures including cryogenic readout components, which enable the

  17. Electron Bunch Length Measurement for LCLS at SLAC

    International Nuclear Information System (INIS)

    Zelazny, M.; Allison, S.; Chevtsov, Sergei; Emma, P.; Kotturi, K.d.; Loos, H.; Peng, S.; Rogind, D.; Straumann, T.

    2007-01-01

    At Stanford Linear Accelerator Center (SLAC) a Bunch Length Measurement system has been developed to measure the length of the electron bunch for its new Linac Coherent Light Source (LCLS). This destructive measurement uses a transverse-mounted RF deflector (TCAV) to vertically streak the electron beam and an image taken with an insertable screen and a camera. The device control software was implemented with the Experimental Physics and Industrial Control System (EPICS) toolkit. The analysis software was implemented in Matlab(trademark) using the EPICS/Channel Access Interface for Scilab(trademark) and Matlab(trademark) (labCA). This architecture allowed engineers and physicists to develop and integrate their control and analysis without duplication of effort

  18. Electron Bunch Length Measurement for LCLS at SLAC

    Energy Technology Data Exchange (ETDEWEB)

    Zelazny, M.; Allison, S.; Chevtsov, Sergei; Emma, P.; Kotturi, K.d.; Loos, H.; Peng, S.; Rogind, D.; Straumann, T.; /SLAC

    2007-10-04

    At Stanford Linear Accelerator Center (SLAC) a Bunch Length Measurement system has been developed to measure the length of the electron bunch for its new Linac Coherent Light Source (LCLS). This destructive measurement uses a transverse-mounted RF deflector (TCAV) to vertically streak the electron beam and an image taken with an insertable screen and a camera. The device control software was implemented with the Experimental Physics and Industrial Control System (EPICS) toolkit. The analysis software was implemented in Matlab{trademark} using the EPICS/Channel Access Interface for Scilab{trademark} and Matlab{trademark} (labCA). This architecture allowed engineers and physicists to develop and integrate their control and analysis without duplication of effort.

  19. Absolute bunch length measurements by incoherent radiation fluctuation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sannibale, Fernando; Stupakov, Gennady; Zolotorev, Max; Filippetto, Daniele; Jagerhofer, Lukas

    2008-09-29

    By analyzing the pulse to pulse intensity fluctuations of the radiation emitted by a charge particle in the incoherent part of the spectrum, it is possible to extract information about the spatial distribution of the beam. At the Advanced Light Source (ALS) of the Lawrence Berkeley National Laboratory, we have developed and successfully tested a simple scheme based on this principle that allows for the absolute measurement of the rms bunch length. A description of the method and the experimental results are presented.

  20. Absolute Bunch Length Measurements by Incoherent Radiation Fluctuation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sannibale, F.; /LBL, Berkeley; Stupakov, G.V.; /SLAC; Zolotorev, M.S.; /LBL, Berkeley; Filippetto, D.; /INFN, Rome; Jagerhofer, L.; /Vienna, Tech. U.

    2009-12-09

    By analyzing the pulse to pulse intensity fluctuations of the radiation emitted by a charge particle in the incoherent part of the spectrum, it is possible to extract information about the spatial distribution of the beam. At the Advanced Light Source (ALS) of the Lawrence Berkeley National Laboratory, we have developed and successfully tested a simple scheme based on this principle that allows for the absolute measurement of the rms bunch length. A description of the method and the experimental results are presented.

  1. Automated translating beam profiler for in situ laser beam spot-size and focal position measurements

    Science.gov (United States)

    Keaveney, James

    2018-03-01

    We present a simple and convenient, high-resolution solution for automated laser-beam profiling with axial translation. The device is based on a Raspberry Pi computer, Pi Noir CMOS camera, stepper motor, and commercial translation stage. We also provide software to run the device. The CMOS sensor is sensitive over a large wavelength range between 300 and 1100 nm and can be translated over 25 mm along the beam axis. The sensor head can be reversed without changing its axial position, allowing for a quantitative estimate of beam overlap with counter-propagating laser beams. Although not limited to this application, the intended use for this device is the automated measurement of the focal position and spot-size of a Gaussian laser beam. We present example data of one such measurement to illustrate device performance.

  2. Electron bunch length measurement at the Vanderbilt FEL

    Energy Technology Data Exchange (ETDEWEB)

    Amirmadhi, F.; Brau, C.A.; Mendenhall, M. [Vanderbilt Free-Electron-Laser Center, Nashville, TN (United States)] [and others

    1995-12-31

    During the past few years, a number of experiments have been performed to demonstrate the possibility to extract the longitudinal charge distribution from spectroscopic measurements of the coherent far-infrared radiation emitted as transition radiation or synchrotron radiation. Coherent emission occurs in a spectral region where the wavelength is comparable to or longer than the bunch length, leading to an enhancement of the radiation intensity that is on the order of the number of particles per bunch, as compared to incoherent radiation. This technique is particularly useful in the region of mm and sub-mm bunch lengths, a range where streak-cameras cannot be used for beam diagnostics due to their limited time resolution. Here we report on experiments that go beyond the proof of principle of this technique by applying it to the study and optimization of FEL performance. We investigated the longitudinal bunch length of the Vanderbilt FEL by analyzing the spectrum of coherent transition radiation emitted by the electron bunches. By monitoring the bunch length while applying a bunch-compression technique, the amount of the compression could be easily observed. This enabled us to perform a systematic study of the FEL performance, especially gain and optical pulse width, as a function of the longitudinal electron distribution in the bunch. The results of this study will be presented and discussed.

  3. Constant-Length Random Substitutions and Gibbs Measures

    Science.gov (United States)

    Maldonado, C.; Trejo-Valencia, L.; Ugalde, E.

    2018-04-01

    This work is devoted to the study of processes generated by random substitutions over a finite alphabet. We prove, under mild conditions on the substitution's rule, the existence of a unique process which remains invariant under the substitution, and which exhibits a polynomial decay of correlations. For constant-length substitutions, we go further by proving that the invariant state is precisely a Gibbs measure which can be obtained as the projective limit of its natural Markovian approximations. We end up the paper by studying a class of substitutions whose invariant state is the unique Gibbs measure for a hierarchical two-body interaction.

  4. The elementary school teachers’ ability in the length measurement

    Science.gov (United States)

    Julie, Hongki

    2017-09-01

    The purpose of this study was to describe the elementary school teachers' mathematical ability (1) to develop students’ activities which constructed longer than, shorter than, and as long as concepts, (2) to develop students’ activities which constructed standard unit on the length measurement, and (3) to develop a problem which used by student to construct why a conversion activity on the unit of the length was useful in the daily life after they have participated in the Realistic Mathematics Education (RME) workshops. Curry and Outhread said if teachers knew more about the growth of students’ conceptual understanding of the length, they would be better able to teach that topic [4]. Therefore, in the workshop, teachers were asked to learn more on the stages of the measurement teaching and learning process and why each stage was important. This capability was described by the results of a test which was content of four problems given to teachers after they have attended the workshop. Research subjects in this study were 14 elementary school teachers at Yogyakarta. The results of the study were as follows: (1) only four of 14 teachers who had the first ability; (2) all teachers had the second ability; and (3) all the teachers did not have the third ability.

  5. π K atom lifetime and π K scattering length measurements

    Science.gov (United States)

    Yazkov, V.; DIRAC Collaboration

    2015-03-01

    Theory, using Low Energy QCD, calculated with high precision the π π and π K scattering length. To check the theoretical calculations for the processes, including s-quarks, we must measure the π K atom lifetime, that is connected to the π K scattering lengths by a precise relation. Evidence for π K atoms production is reported on a base of a number of produced π K atoms found to be N A = 653±42 together with the value of the π K pairs from atoms that breakup in the same target n A = 178±49. Using these results the analysis yields to a first value for the π K atom lifetime of τ = 2.5^{+3.0}_{-1.8} fs and a first model-independent measurement of the S-wave isospin-odd π K scattering length |a-0| = 1/3 |a^{1/2}0 - a^{3/2}0| = 0.11^{+0.09}_{-0.04} M^{-1}_{π } (the I and L in {aIL} stands for isospin and orbital momentum).

  6. Length-free near infrared measurement of newborn malnutrition

    Science.gov (United States)

    Mustafa, Fatin Hamimi; Bek, Emily J.; Huvanandana, Jacqueline; Jones, Peter W.; Carberry, Angela E.; Jeffery, Heather E.; Jin, Craig T.; McEwan, Alistair L.

    2016-11-01

    Under-nutrition in neonates can cause immediate mortality, impaired cognitive development and early onset adult disease. Body fat percentage measured using air-displacement-plethysmography has been found to better indicate under-nutrition than conventional birth weight percentiles. However, air-displacement-plethysmography equipment is expensive and non-portable, so is not suited for use in developing communities where the burden is often the greatest. We proposed a new body fat measurement technique using a length-free model with near-infrared spectroscopy measurements on a single site of the body - the thigh. To remove the need for length measurement, we developed a model with five discrete wavelengths and a sex parameter. The model was developed using air-displacement-plethysmography measurements in 52 neonates within 48 hours of birth. We identified instrumentation required in a low-cost LED-based screening device and incorporated a receptor device that can increase the amount of light collected. This near-infrared method may be suitable as a low cost screening tool for detecting body fat levels and monitoring nutritional interventions for malnutrition in neonates and young children in resource-constrained communities.

  7. Measurement of neutron diffusion length in heavy concrete

    International Nuclear Information System (INIS)

    Krejci, D.

    2007-04-01

    Using an aluminium sampler filled with heavy concrete the neutron diffusion length was determined, measuring thermal and fast neutrons over the whole beam hole with various threshold detectors using gold samples. These calculations should describe the neutron distribution in the whole concrete shield of the reactor and contribute to the investigation of the activation of the concrete shield using reactor parameters like operating time, power and neutron flux. Instrumentation, activation and positioning of the samples in the beam hole of the TRIGA Mark II reactor are described. (nevyjel)

  8. An inversion formula for the exponential Radon transform in spatial domain with variable focal-length fan-beam collimation geometry

    International Nuclear Information System (INIS)

    Wen Junhai; Liang Zhengrong

    2006-01-01

    Inverting the exponential Radon transform has a potential use for SPECT (single photon emission computed tomography) imaging in cases where a uniform attenuation can be approximated, such as in brain and abdominal imaging. Tretiak and Metz derived in the frequency domain an explicit inversion formula for the exponential Radon transform in two dimensions for parallel-beam collimator geometry. Progress has been made to extend the inversion formula for fan-beam and varying focal-length fan-beam (VFF) collimator geometries. These previous fan-beam and VFF inversion formulas require a spatially variant filtering operation, which complicates the implementation and imposes a heavy computing burden. In this paper, we present an explicit inversion formula, in which a spatially invariant filter is involved. The formula is derived and implemented in the spatial domain for VFF geometry (where parallel-beam and fan-beam geometries are two special cases). Phantom simulations mimicking SPECT studies demonstrate its accuracy in reconstructing the phantom images and efficiency in computation for the considered collimator geometries

  9. Fabrication of long-focal-length plano-convex microlens array by combining the micro-milling and injection molding processes.

    Science.gov (United States)

    Chen, Lei; Kirchberg, Stefan; Jiang, Bing-Yan; Xie, Lei; Jia, Yun-Long; Sun, Lei-Lei

    2014-11-01

    A uniform plano-convex spherical microlens array with a long focal length was fabricated by combining the micromilling and injection molding processes in this work. This paper presents a quantitative study of the injection molding process parameters on the uniformity of the height of the microlenses. The variation of the injection process parameters, i.e., barrel temperature, mold temperature, injection speed, and packing pressure, was found to have a significant effect on the uniformity of the height of the microlenses, especially the barrel temperature. The filling-to-packing switchover point is also critical to the uniformity of the height of the microlenses. The optimal uniformity was achieved when the polymer melts completely filled the mold cavity, or even a little excessively filled the cavity, during the filling stage. In addition, due to the filling resistance, the practical filling-to-packing switchover point can vary with the change of the filling processing conditions and lead to a non-negligible effect on the uniformity of the height of the microlenses. Furthermore, the effect of injection speed on the uniformity of the height of the microlenses was analyzed in detail. The results indicated that the effect of injection speed on the uniformity of the height of the microlenses is mainly attributed to the two functions of injection speed: transferring the filling-to-packing switchover point and affecting the distribution of residual flow stress in the polymer melt.

  10. Measurements and comparison of focal spot sizes of two types of x-ray tubes installed in simulators

    International Nuclear Information System (INIS)

    Wen, C.; Sorell, G.; Hille, N.

    1996-01-01

    Full text: Measurements of the effective focal spot size of two types of X-ray tubes installed in radiotherapeutic simulators (TOSHIBA and VARIAN-Ximatron) are presented. As recommended in ACPSEM Quality Assurance Protocols for Diagnostic X-ray Equipment [Heggie and Petty, APESM, Vol.8 No.1 1985], the effective focal spot size of X-ray tube is vital in determining the maximum resolution of radiographic and fluoroscopic images. Hence, the quality of clinical performance of diagnostic equipment is depended to a large extent upon the accuracy in measuring and maintaining the focal spot size of the X-ray tube and regular QA program. In determining the shape and the dimension of the effective focal spot that is located within the X-ray tube and can not be measured directly, a method developed by Spiegler and Breckinridge [Spiegler and Breckinrige, Radiation Physics, Vol. 102 Mar. 1972] was used. By irradiating a lead star pattern which is placed in a divert X-ray beam between the tube and a negative film, a magnified radiographic image of the test pattern can be obtained from a standard X-ray film. The actual shape of the effective focus is determined by tracing the locus of the image intensity inversion of the radial pattern where that is occurring when only a certain condition of spatial variation from a central ray-line is met. Then, the dimension of the focal spot can be calculated. In this measurements, three different test patterns (Typ 9/1, 5 deg Vertex Angle 0.03 mm Pb, Typ 9-2 deg-360 0.05 mmPb and Typ 9 Teilung 2 deg 0.05 mm Pb) with same diameter of 45 mm are used. Results from a series measurements which were carried out repetitively under same working condition of both simulators indicate that the effective focal spots of these two tubes are of similar rectangular shape. However, the dimensions of the focal spots are about 1.297 X 0.848 mm for the TOSHIBA tube and 0.692 X 0.532 mm for the Ximatron tube. The orientation of the focal spot for TOSHIBA tube is

  11. Philtrum length and intercommissural distance measurements at mixed dentition period.

    Science.gov (United States)

    Mostafa, Mostafa; Hassib, Nehal; Sayed, Inas; Neamat, Amany; Ramzy, Magda; El-Badry, Tarek; ElGabry, Hisham; Salem, Haidy; Omar, Nada; Ismail, Amira; Ibrahim, Yousra; Shebaita, Amr; Allam, Ahmed; Mostafa, Magdy

    2018-05-01

    Anthropometric measurements of the lip and mouth are of great importance in clinical dysmorphology as well as reconstructive plastic surgery. In this study, the philtrum length (PhL) and intercommissural distance (ICmD) nomograms for Egyptian children in the mixed dentition period were established. A group of 1,338 Egyptian students in primary schools (735 boys and 603 girls) were included in the study. The students were at mixed dentition period and their ages ranged from 7 to 12 years. Anthropometric norms of PhL and ICmD were developed with significant sex difference in certain groups. A ratio between PhL and ICmD was developed. These data will help facilitate both objective and subjective evaluation of the lip and mouth for proper diagnosis of orofacial anomalies and variations as well as for ideal treatment plans. © 2018 Wiley Periodicals, Inc.

  12. Measuring (subglacial bedform orientation, length, and longitudinal asymmetry - Method assessment.

    Directory of Open Access Journals (Sweden)

    Marco G Jorge

    Full Text Available Geospatial analysis software provides a range of tools that can be used to measure landform morphometry. Often, a metric can be computed with different techniques that may give different results. This study is an assessment of 5 different methods for measuring longitudinal, or streamlined, subglacial bedform morphometry: orientation, length and longitudinal asymmetry, all of which require defining a longitudinal axis. The methods use the standard deviational ellipse (not previously applied in this context, the longest straight line fitting inside the bedform footprint (2 approaches, the minimum-size footprint-bounding rectangle, and Euler's approximation. We assess how well these methods replicate morphometric data derived from a manually mapped (visually interpreted longitudinal axis, which, though subjective, is the most typically used reference. A dataset of 100 subglacial bedforms covering the size and shape range of those in the Puget Lowland, Washington, USA is used. For bedforms with elongation > 5, deviations from the reference values are negligible for all methods but Euler's approximation (length. For bedforms with elongation < 5, most methods had small mean absolute error (MAE and median absolute deviation (MAD for all morphometrics and thus can be confidently used to characterize the central tendencies of their distributions. However, some methods are better than others. The least precise methods are the ones based on the longest straight line and Euler's approximation; using these for statistical dispersion analysis is discouraged. Because the standard deviational ellipse method is relatively shape invariant and closely replicates the reference values, it is the recommended method. Speculatively, this study may also apply to negative-relief, and fluvial and aeolian bedforms.

  13. In-vivo measurements of human brain tissue conductivity using focal electrical current injection through intracerebral multicontact electrodes.

    Science.gov (United States)

    Koessler, Laurent; Colnat-Coulbois, Sophie; Cecchin, Thierry; Hofmanis, Janis; Dmochowski, Jacek P; Norcia, Anthony M; Maillard, Louis G

    2017-02-01

    In-vivo measurements of human brain tissue conductivity at body temperature were conducted using focal electrical currents injected through intracerebral multicontact electrodes. A total of 1,421 measurements in 15 epileptic patients (age: 28 ± 10) using a radiofrequency generator (50 kHz current injection) were analyzed. Each contact pair was classified as being from healthy (gray matter, n = 696; white matter, n = 530) or pathological (epileptogenic zone, n = 195) tissue using neuroimaging analysis of the local tissue environment and intracerebral EEG recordings. Brain tissue conductivities were obtained using numerical simulations based on conductivity estimates that accounted for the current flow in the local brain volume around the contact pairs (a cube with a side length of 13 mm). Conductivity values were 0.26 S/m for gray matter and 0.17 S/m for white matter. Healthy gray and white matter had statistically different median impedances (P conductivity was found to be homogeneous as normality tests did not find evidence of multiple subgroups. Gray matter had lower conductivity in healthy tissue than in the epileptogenic zone (0.26 vs. 0.29 S/m; P = 0.012), even when the epileptogenic zone was not visible in the magnetic resonance image (MRI) (P = 0.005). The present in-vivo conductivity values could serve to create more accurate volume conduction models and could help to refine the identification of relevant intracerebral contacts, especially when located within the epileptogenic zone of an MRI-invisible lesion. Hum Brain Mapp 38:974-986, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  14. Determination of funnel length from cross section versus LET measurements

    International Nuclear Information System (INIS)

    Golke, K.W.

    1993-01-01

    This paper proposes an empirical model and method for determining the funnel length from heavy ion upset cross section as a function LET data. It is valid for bulk technologies having a lightly doped epi region over a heavily doped substrate region. Definition of the funnel length is necessary in order to define the heavy ion track length along which charge is collected. Knowing the track length and the threshold LET for upset, the critical charge can be calculated. Critical charge as well as sensitive volume dimensions for upset are required input parameters for upset calculation codes such as CREME. The more accurate the critical charge calculation, the more accurate the calculated upset rate

  15. Ocular Axial Length Measurement Among Normal Adults Using ...

    African Journals Online (AJOL)

    2017-07-26

    Jul 26, 2017 ... Background/Introduction: Macrophthalmia and microphthalmia are cardinal signs of many orbito-ocular and systemic diseases which are seen in northern Nigeria. Some cases of refractive error may also be directly related to the ocular axial length (AL). The need for an imaging parameter that will aid their ...

  16. Antennas for Terahertz Applications: Focal Plane Arrays and On-chip Non-contact Measurement Probes

    Science.gov (United States)

    Trichopoulos, Georgios C.

    The terahertz (THz) band provides unique sensing opportunities that enable several important applications such as biomedical imaging, remote non-destructive inspection of packaged goods, and security screening. THz waves can penetrate most materials and can provide unique spectral information in the 0.1--10 THz band with high resolution. In contrast, other imaging modalities, like infrared (IR), suffer from low penetration depths and are thus not attractive for non-destructive evaluation. However, state-of-the-art THz imaging systems typically employ mechanical raster scans using a single detector to acquire two-dimensional images. Such devices tend to be bulky and complicated due to the mechanical parts, and are thus rather expensive to develop and operate. Thus, large-format (e.g. 100x100 pixels) and all-electronics based THz imaging systems are badly needed to alleviate the space, weight and power (SWAP) factors and enable cost effective utilization of THz waves for sensing and high-data-rate communications. In contrast, photonic sensors are very compact because light can couple directly to the photodiode without residing to radiation coupling topologies. However, in the THz band, due to the longer wavelengths and much lower photon energies, highly efficient antennas with optimized input impedance have to be integrated with THz sensors. Here, we implement novel antenna engineering techniques that are optimized to take advantage of recent technological advances in solid-state THz sensing devices. For example, large-format focal plane arrays (FPAs) have been the Achilles' heel of THz imaging systems. Typically, optical components (lenses, mirrors) are employed in order to improve the optical performance of FPAs, however, antenna sensors suffer from degraded performance when they are far from the optical axis, thus minimizing the number of useful FPA elements. By modifying the radiation pattern of FPA antennas we manage to alleviate the off-axis aberration

  17. Reducing trial length in force platform posturographic sleep deprivation measurements

    Science.gov (United States)

    Forsman, P.; Hæggström, E.; Wallin, A.

    2007-09-01

    Sleepiness correlates with sleep-related accidents, but convenient tests for sleepiness monitoring are scarce. The posturographic test is a method to assess balance, and this paper describes one phase of the development of a posturographic sleepiness monitoring method. We investigated the relationship between trial length and accuracy of the posturographic time-awake (TA) estimate. Twenty-one healthy adults were kept awake for 32 h and their balance was recorded, 16 times with 30 s trials, as a function of TA. The balance was analysed with regards to fractal dimension, most common sway amplitude and time interval for open-loop stance control. While a 30 s trial allows estimating the TA of individual subjects with better than 5 h accuracy, repeating the analysis using shorter trial lengths showed that 18 s sufficed to achieve the targeted 5 h accuracy. Moreover, it was found that with increasing TA, the posturographic parameters estimated the subjects' TA more accurately.

  18. Measurement of electron beam bunch phase length by rectangular cavities

    International Nuclear Information System (INIS)

    Afanas'ev, V.D.; Rudychev, V.G.; Ushakov, V.I.

    1976-01-01

    An analysis of a phase length of electron bunches with the help of crossed rectangular resonators with the Hsub(102) oscillation type has been made. It has been shown that the electron coordinates after the duplex resonator are described by an ellipse equation for a non-modulated beam. An influence of the initial energy spread upon the electron motion has been studied. It has been ascertained that energy modulation of the electron beam results in displacement of each electron with respect to the ellipse which is proportional to modulation energy, i.e. an error in determination of the phase length of an electron bunch is proportional to the beam energy spread. Relations have been obtained which enable to find genuine values of phases of the analyzed electrons with an accuracy up to linear multipliers

  19. Dynamic Length Metrology (DLM) for measurements with sub-micrometre uncertainty in a production environment

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Hansen, Hans Nørgaard; Hattel, Jesper Henri

    2016-01-01

    Conventional length metrology for traceable accurate measurements requires costly temperature controlled facilities, long waiting time for part acclimatisation, and separate part material characterisation. This work describes a method called Dynamic Length Metrology (DLM) developed to achieve sub...

  20. Focal cerebral ischemia measured by the intra-arterial 133xenon method. Limitations of 2-dimensional blood flow measurements

    DEFF Research Database (Denmark)

    Skyhøj Olsen, T; Larsen, B; Bech Skriver, E

    1981-01-01

    The limitations of 2-dimensional isotope techniques in the study of focal cerebral ischemia were investigated using the intra-carotid 133 xenon injection method and a 254 multidetector scintillation camera. To make sure that the detectors "look" directly on infarcted areas, only patients with inf...

  1. Statistical length of DNA based on AFM image measured by a computer

    International Nuclear Information System (INIS)

    Chen Xinqing; Qiu Xijun; Zhang Yi; Hu Jun; Wu Shiying; Huang Yibo; Ai Xiaobai; Li Minqian

    2001-01-01

    Taking advantage of image processing technology, the contour length of DNA molecule was measured automatically by a computer. Based on the AFM image of DNA, the topography of DNA was simulated into a curve. Then the DNA length was measured automatically by inserting mode. It was shown that the experimental length of a naturally deposited DNA (180.4 +- 16.4 nm) was well consistent with the theoretical length (185.0 nm). Comparing to other methods, the present approach had advantages of precision and automatism. The stretched DNA was also measured. It present approach had advantages of precision and automatism. The stretched DNA was also measured. It was shown that the experimental length (343.6 +- 20.7 nm) was much longer than the theoretical length (307.0 nm). This result indicated that the stretching process had a distinct effect on the DNA length. However, the method provided here avoided the DNA-stretching effect

  2. An induction sensor for measuring rectilinear movements of substantial length

    International Nuclear Information System (INIS)

    Jaudou, Yves.

    1973-01-01

    The invention is characterized in that it comprises the steps of making one end of a magnetic core integral with the objet, the movements of which are to be measured. The core has the shape of an isoscele prism the base surface of which slides within two aligned coils contained in two adjacent arms of an A-C operated Wheatstone bridge. The impedances in the W-bridge other two arms is adjusted in order that the Wheatstone bridge be balanced at a given position of the object. The movement of the object is measured from the latter given position through the potential difference, proportional to said movement developed between two opposite apices E and D of the bridge, the latter being fed with AC between the other two apices (A and B). This can be applied to the measurement of the movements of irradiation capsules in a nuclear reactor [fr

  3. Esophageal distensibility measurement: impact on clinical management and procedure length.

    Science.gov (United States)

    Ahuja, N K; Agnihotri, A; Lynch, K L; Hoo-Fatt, D; Onyimba, F; McKnight, M; Okeke, F C; Garcia, P; Dhalla, S; Stein, E; Pasricha, P J; Clarke, J O

    2017-08-01

    Luminal distensibility measurement has demonstrated relevance to various disease processes, though its effects on clinical decision-making have been less well understood. This study aims to characterize the clinical impact of impedance planimetry measurement as well as the learning curve associated with its use in the esophagus. A single provider performed distensibility measurement in conjunction with upper endoscopy for a variety of clinical indications with the functional lumen imaging probe (FLIP) over a period of 21 months. Procedural data were prospectively collected and, along with medical records, retrospectively reviewed. Seventy-three procedures (70 patients) underwent esophageal distensibility measurement over the timeline of this study. The most common procedural indications were known or suspected achalasia (32.9%), dysphagia with connective tissue disease (13.7%), eosinophilic esophagitis (12.3%), and dysphagia with prior fundoplication (9.6%). FLIP results independently led to a change in management in 29 (39.7%) cases and supported a change in management in an additional 15 (20.5%) cases. The most common change in management was a new or amended therapeutic procedure (79.5%). Procedural time added by distensibility measurement was greater among earlier cases than among later cases. The median time added overall was 5 minutes and 46 seconds. Procedural time added varied significantly by procedural indication, but changes in management did not. Distensibility measurement added meaningful diagnostic information that impacted therapeutic decision-making in the majority of cases in which it was performed. Procedural time added by this modality is typically modest and decreases with experience. © The Authors 2017. Published by Oxford University Press on behalf of International Society for Diseases of the Esophagus. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  4. Cervical length measurement: comparison of transabdominal and transvaginal approach

    DEFF Research Database (Denmark)

    Westerway, Sue C; Pedersen, Lars Henning; Hyett, Jon

    2015-01-01

    accurately, particularly if the cervix is short. At 24–34 weeks, a policy of proceeding to TV scan if TA measurement is positive predictive value so is of limited value as a predictive tool for women attending with symptoms and signs...... of preterm labour > 24 weeks gestation. There is no value in TA assessment of the cervix > 36 weeks....

  5. The reliability of transabdominal cervical length measurement in a low-risk obstetric population: Comparison with transvaginal measurement.

    Science.gov (United States)

    Peng, Cheng-Ran; Chen, Chie-Pein; Wang, Kuo-Gon; Wang, Liang-Kai; Chen, Chen-Yu; Chen, Yi-Yung

    2015-04-01

    To determine the correlation between transabdominal (TA) and transvaginal (TV) cervical length measurement in a low-risk obstetric population in Taiwan. Women with a singleton pregnancy between 20 weeks and 24 weeks of gestation underwent postvoid TA and TV cervical length measurements. Differences between the measurements obtained using the two methods were evaluated. Two hundred and five women agreed to participate in the study. Paired TA and TV measurements were obtained in 174 women. The mean TA cervical length was 36.0 ± 4.9 mm and the mean TV cervical length was 37.6 ± 5.4 mm. The mean TA cervical length was shorter than the mean TV cervical length by 1.6 mm. The 5(th) percentile of TA and TV cervical length was 29 mm and 29.1 mm, respectively. The discrepancies between the two methods were not significantly correlated with maternal body mass index (BMI). All women with TV cervical length women in the present study, and the TA cervical length was closely correlated with the TV cervical length. The use of TA ultrasound could be an effective initial tool for cervical length screening in low-risk pregnant women. TA cervical length TV ultrasound. Copyright © 2015. Published by Elsevier B.V.

  6. Normal standards for kidney length as measured with US in premature infants

    International Nuclear Information System (INIS)

    Schlesinger, A.E.; Hedlund, G.L.; Pierson, W.P.; Null, D.M.

    1986-01-01

    In order to develop normal standards for kidney length in premature infants, the authors measured kidney length by US imaging in 39 (to date) premature infants less than 72 hours old and without known renal disease. Kidney length was compared with four different parameters of body size, including gestational age, birth weight, birth length, and body surface area. Similar standards have been generated previously for normal renal length as measured by US imaging in full-term infants and older children. These standards have proven utility in cases of congenital and acquired disorders that abnormally increase or decrease renal size. Scatter plots of kidney length versus body weight and kidney length versus body surface area conformed well to a logarithmic distribution, with a high correlation coefficient and close-fitting 95% confidence limits (SEE = 2.05)

  7. Subpicometer Length Measurement Using Semiconductor Laser Tracking Frequency Gauge

    Science.gov (United States)

    Thapa, Rajesh; Phillips, James D.; Rocco, Emanuele; Reasenburg, Robert D.

    2011-01-01

    We have demonstrated heretofore unattained distance precision of 0:14pm (2pm) incremental and 14nm (2.9 micrometers) absolute in a resonant (nonresonant) interferometer at an averaging time of 1 s, using inexpensive telecommunications diode lasers. We have controlled the main source of error, that due to spurious reflection and the resulting amplitude modulation. In the resonant interferometer, absolute distance precision is well under lambda/6. Therefore, after an interruption, an absolute distance measurement can be used to return to the same interferometer order.

  8. Effect of various digital processing algorithms on the measurement accuracy of endodontic file length.

    Science.gov (United States)

    Kal, Betül Ilhan; Baksi, B Güniz; Dündar, Nesrin; Sen, Bilge Hakan

    2007-02-01

    The aim of this study was to compare the accuracy of endodontic file lengths after application of various image enhancement modalities. Endodontic files of three different ISO sizes were inserted in 20 single-rooted extracted permanent mandibular premolar teeth and standardized images were obtained. Original digital images were then enhanced using five processing algorithms. Six evaluators measured the length of each file on each image. The measurements from each processing algorithm and each file size were compared using repeated measures ANOVA and Bonferroni tests (P = 0.05). Paired t test was performed to compare the measurements with the true lengths of the files (P = 0.05). All of the processing algorithms provided significantly shorter measurements than the true length of each file size (P 0.05). Decrease in mean error value was observed with increasing file size (P file length measurements when utilizing storage phosphor plates.

  9. A paired-laser photogrammetric method for in situ length measurement of benthic fishes

    Science.gov (United States)

    Rizzo, Austin A.; Welsh, Stuart A.; Thompson, Patricia A.

    2017-01-01

    Photogrammetry, a technique to obtain measurements from photographs, may be a valid method for measuring lengths of rare, threatened, or endangered species. Photogrammetric methods of measurement are nonintrusive and reduce the possibility of physical damage or physiological stress associated with the capture and handling of individuals. We evaluated precision and accuracy of photogrammetric length measurements relative to board measurements of Greenside Darters Etheostoma blennioides and Variegate Darters E. variatum in an aquarium and applied photogrammetry in a field study of the Diamond Darter Crystallaria cincotta, a federally listed endangered species. Digital photographs were taken of each individual using a waterproof camera equipped with two parallel lasers. Photogrammetric length measurements were digitized with ImageJ software. Agreement between board and photogrammetric measurements were high for Greenside and Variegate darters. The magnitude of differences was small between direct and photogrammetric measurements, ranging from 0.6% to 3.1%, depending on the species measured and the type of measurement taken. These results support photogrammetry as a useful method for obtaining length measurements of benthic stream fishes. Photogrammetric methods allowed for length measurements and an assessment of length frequency of 199 Diamond Darters, informative data for management that could not be collected with conventional measuring-board methods.

  10. Experimental Investigation Of The Real Contact Arc Length Measurement In The Cylindrical Plunge Grinding

    Directory of Open Access Journals (Sweden)

    Pang Jingzhu

    2016-01-01

    Full Text Available The real contact arc length in grinding is one of the most important indicators in investigating of the material removal mechanism for precision machining. It is generally affected by a combination of plastic and thermal deformations in the machining process. This paper will provide a systematic investigation of the contact arc length in the cylindrical grinding of titanium alloy Ti-6Al-4V. A series of single grit experiments and grinding temperature measurements, together with FEM simulation, will be utilized to determine the real contact arc length. The contact behavior between a grinding wheel and the workpiece was investigated by the contact time in the workpice surface temperature curves. It was found that in FEM simulation, the real contact length was about 2 times of the geometric length. With the experimental results of the different grinding parameters, the real contact lengths calculated by temperature curves were about 1.5 - 2 times of the geometric length.

  11. Utility of telomere length measurements for age determination of humpback whales

    Directory of Open Access Journals (Sweden)

    Morten Tange Olsen

    2014-12-01

    Full Text Available This study examines the applicability of telomere length measurements by quantitative PCR as a tool for minimally invasive age determination of free-ranging cetaceans. We analysed telomere length in skin samples from 28 North Atlantic humpback whales (Megaptera novaeangliae, ranging from 0 to 26 years of age. The results suggested a significant correlation between telomere length and age in humpback whales. However, telomere length was highly variable among individuals of similar age, suggesting that telomere length measured by quantitative PCR is an imprecise determinant of age in humpback whales. The observed variation in individual telomere length was found to be a function of both experimental and biological variability, with the latter perhaps reflecting patterns of inheritance, resource allocation trade-offs, and stochasticity of the marine environment.

  12. Automatic measurement of axial length of human eye using three-dimensional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Watanabe, Masaki; Kiryu, Tohru

    2011-01-01

    The measurement of axial length and the evaluation of three dimensional (3D) form of an eye are essential to evaluate the mechanism of myopia progression. We propose a method of automatic measurement of axial length including adjustment of the pulse sequence of short-term scan which could suppress influence of eyeblink, using a magnetic resonance imaging (MRI) which acquires 3D images noninvasively. Acquiring T 2 -weighted images with 3.0 tesla MRI device and eight-channel phased-array head coil, we extracted left and right eye ball images, and then reconstructed 3D volume. The surface coordinates were calculated from 3D volume, fitting the ellipsoid model coordinates with the surface coordinates, and measured the axial length automatically. Measuring twenty one subjects, we compared the automatically measured values of axial length with the manually measured ones, then confirmed significant elongation in the axial length of myopia compared with that of emmetropia. Furthermore, there were no significant differences (P<0.05) between the means of automatic measurements and the manual ones. Accordingly, the automatic measurement process of axial length could be a tool for the elucidation of the mechanism of myopia progression, which would be suitable for evaluating the axial length easily and noninvasively. (author)

  13. Significance of axial length monitoring in children with congenital cataract and update of measurement methods.

    Science.gov (United States)

    Zhan, Jiao; Lin, Haotian; Zhang, Xinyu; Chen, Weirong; Liu, Yizhi

    2013-06-01

    Congenital cataract is the main cause of blindness in children, with significantly varying treatment effects. The development of axial length is an important factor that affects the prognosis of these children. However, when compared with the eyes of normal children, the mechanism of growth of the axial length is so complicated that the reported findings differ significantly in terms of the measuring apparatus, assessment methods, and statistical outcome, making the rule of axial length development still unclear. In this paper, we first review the process of axial length development in normal healthy children and compare different hypotheses about certain factors that could affect the development of axial length. The results of some current research about the characteristics of axial length development in congenital cataract children are then reviewed. Lastly, the advantages and disadvantages of current axial length measurements methods are compared and analyzed. The purpose of this review is to improve our understanding of the complexity and importance of axial length development and to suggest better use of axial length monitoring measurements in congenital cataract children for pediatric ophthalmologists, with the hope of offering assistance that will enhance long-term therapeutic effects for these children.

  14. Measurement accuracy and reliability of tooth length on conventional and CBCT reconstructed panoramic radiographs

    Science.gov (United States)

    Flores-Mir, Carlos; Rosenblatt, Mark R; Major, Paul W.; Carey, Jason P.; Heo, Giseon

    2014-01-01

    INTRODUCTION: This in vivo study assessed accuracy and reliability of tooth length measurements obtained from conventional panoramic radiographs and CBCT panoramic reconstructions to that of a digital caliper (gold standard). METHODS: The sample consisted of subjects who had CBCT and conventional panoramic radiographic imaging and who required maxillary premolar extraction for routine orthodontic treatment. A total of 48 teeth extracted from 26 subjects were measured directly with digital calipers. Radiographic images were scanned and digitally measured in Dolphin 3D software. Accuracy of tooth length measurements made by CBCT panoramic reconstructions, conventional panoramic radiographs and digital caliper (gold standard) were compared to each other by repeated measures one-way ANOVA with Bonferroni correction and by single measures intraclass correlation coefficient. RESULTS: Repeated root length measures with digital calipers, panoramic radiographs and CBCT constructed panoramic-like images were all individually highly reliable. Compared to the caliper (gold standard), tooth measurements obtained from conventional panoramic radiographs were on average 6.3 mm (SD = 2.0 mm) longer, while tooth measurements from CBCT panoramic reconstructions were an average of 1.7 mm (SD = 1.2 mm) shorter. CONCLUSIONS: In comparison to actual tooth lengths, conventional panoramic radiographs were relatively inaccurate, overestimating the lengths by 29%, while CBCT panoramic reconstructions underestimated the lengths by 4%. PMID:25715716

  15. Measurement of subpicosecond bunch lengths using coherent Smith-Purcell radiation

    Directory of Open Access Journals (Sweden)

    S. E. Korbly

    2006-02-01

    Full Text Available We report the use of coherent Smith-Purcell radiation to measure the bunch length of femtosecond-scale, 15 MeV electron bunches produced by a 17 GHz rf accelerator. The Smith-Purcell radiation was produced by passing a train of electron bunches above a metal grating. The radiation was verified as Smith-Purcell radiation by measuring the resonance condition, dependence on beam current, and dependence on beam height above the grating. Measurements of the intensity of the radiation vs emission angle were analyzed to obtain the bunch length. The accelerator was operated in two different modes, producing bunches that were determined to have bunch lengths of 600 and 1000±200  fs. These nondestructive bunch length measurements were found to agree well with an independent, but destructive, measurement using a microwave deflecting cavity.

  16. Blood and dried blood spot telomere length measurement by qPCR: assay considerations.

    Directory of Open Access Journals (Sweden)

    DeAnna L Zanet

    Full Text Available Measurement of telomere length is crucial for the study of telomere maintenance and its role in molecular pathophysiology of diseases and in aging. Several methods are used to measure telomere length, the choice of which usually depends on the type and size of sample to be assayed, as well as cost and throughput considerations. The goal of this study was to investigate the factors that may influence the reliability of qPCR-based relative telomere length measurements in whole blood. Day to day intra-individual variability, types of blood anticoagulant, sample storage conditions, processing and site of blood draw were investigated. Two qPCR-based methods to measure telomere length (monoplex vs. multiplex were also investigated and showed a strong correlation between them. Freezing and thawing of the blood and storage of the blood at 4°C for up to 4 days did not affect telomere length values. Telomere lengths in dried blood spots were significantly higher than both whole blood and peripheral mononuclear blood cells, and were highly correlated with both. We found that telomere length measurements were significantly higher in dried blood spots collected directly from fingertip prick compared to dried blood spots prepared with anticoagulated whole blood collected from the finger, and non-blotted whole blood taken from both finger and arm venipuncture. This suggests that DNA from cells blotted on paper is not equivalent to that collected from venipuncture whole blood, and caution should be taken when comparing between blood sample types.

  17. The localization of focal heart activity via body surface potential measurements: tests in a heterogeneous torso phantom

    Science.gov (United States)

    Wetterling, F.; Liehr, M.; Schimpf, P.; Liu, H.; Haueisen, J.

    2009-09-01

    The non-invasive localization of focal heart activity via body surface potential measurements (BSPM) could greatly benefit the understanding and treatment of arrhythmic heart diseases. However, the in vivo validation of source localization algorithms is rather difficult with currently available measurement techniques. In this study, we used a physical torso phantom composed of different conductive compartments and seven dipoles, which were placed in the anatomical position of the human heart in order to assess the performance of the Recursively Applied and Projected Multiple Signal Classification (RAP-MUSIC) algorithm. Electric potentials were measured on the torso surface for single dipoles with and without further uncorrelated or correlated dipole activity. The localization error averaged 11 ± 5 mm over 22 dipoles, which shows the ability of RAP-MUSIC to distinguish an uncorrelated dipole from surrounding sources activity. For the first time, real computational modelling errors could be included within the validation procedure due to the physically modelled heterogeneities. In conclusion, the introduced heterogeneous torso phantom can be used to validate state-of-the-art algorithms under nearly realistic measurement conditions.

  18. The localization of focal heart activity via body surface potential measurements: tests in a heterogeneous torso phantom

    Energy Technology Data Exchange (ETDEWEB)

    Wetterling, F; Liehr, M; Haueisen, J [Biomagnetic Center, Department of Neurology, Friedrich Schiller University Jena, Jena (Germany); Schimpf, P [Department of Computer Science, Eastern Washington University, Cheney, WA (United States); Liu, H [Massachusetts General Hospital, Massachusetts Institute of Technology and Harvard Medical School, Boston, MA (United States)], E-mail: wetterlf@tcd.ie

    2009-09-21

    The non-invasive localization of focal heart activity via body surface potential measurements (BSPM) could greatly benefit the understanding and treatment of arrhythmic heart diseases. However, the in vivo validation of source localization algorithms is rather difficult with currently available measurement techniques. In this study, we used a physical torso phantom composed of different conductive compartments and seven dipoles, which were placed in the anatomical position of the human heart in order to assess the performance of the Recursively Applied and Projected Multiple Signal Classification (RAP-MUSIC) algorithm. Electric potentials were measured on the torso surface for single dipoles with and without further uncorrelated or correlated dipole activity. The localization error averaged 11 {+-} 5 mm over 22 dipoles, which shows the ability of RAP-MUSIC to distinguish an uncorrelated dipole from surrounding sources activity. For the first time, real computational modelling errors could be included within the validation procedure due to the physically modelled heterogeneities. In conclusion, the introduced heterogeneous torso phantom can be used to validate state-of-the-art algorithms under nearly realistic measurement conditions.

  19. The localization of focal heart activity via body surface potential measurements: tests in a heterogeneous torso phantom

    International Nuclear Information System (INIS)

    Wetterling, F; Liehr, M; Haueisen, J; Schimpf, P; Liu, H

    2009-01-01

    The non-invasive localization of focal heart activity via body surface potential measurements (BSPM) could greatly benefit the understanding and treatment of arrhythmic heart diseases. However, the in vivo validation of source localization algorithms is rather difficult with currently available measurement techniques. In this study, we used a physical torso phantom composed of different conductive compartments and seven dipoles, which were placed in the anatomical position of the human heart in order to assess the performance of the Recursively Applied and Projected Multiple Signal Classification (RAP-MUSIC) algorithm. Electric potentials were measured on the torso surface for single dipoles with and without further uncorrelated or correlated dipole activity. The localization error averaged 11 ± 5 mm over 22 dipoles, which shows the ability of RAP-MUSIC to distinguish an uncorrelated dipole from surrounding sources activity. For the first time, real computational modelling errors could be included within the validation procedure due to the physically modelled heterogeneities. In conclusion, the introduced heterogeneous torso phantom can be used to validate state-of-the-art algorithms under nearly realistic measurement conditions.

  20. Comparison of Wright's Formula and the Dunn Method for Measuring the Umbilical Arterial Catheter Insertion Length

    Directory of Open Access Journals (Sweden)

    Se-ra Min

    2015-04-01

    Conclusion: The use of Wright's formula overall results in superior correct placement of the UAC tip. It may be a more accurate and practical method than the conventional practice for measuring the UAC insertion length in newborns.

  1. Automatic species recognition, length measurement and weight determination, using the CatchMeter computer vision system

    OpenAIRE

    Svellingen, Cato; Totland, Bjørn; White, Darren; Øvredal, Jan Tore

    2006-01-01

    The collection of biological data on species composition and individual length and weight of specimen has always been an important part of fisheries research. Traditionally, the collected information has been recorded on paper prior to being entered into a computer for analysis. Electronic measuring boards that record length measurements, such as the FishMeter (Øvredal and Totland, 2000), have made the data collection process more efficient and reliable. In this contribution we describe a vis...

  2. Preliminary result of bunch length measurement using a modified Michelson interferometer

    International Nuclear Information System (INIS)

    Lin Xuling; Luo Feng; Bei Hua; Dai Zhimin; Chinese Academy of Sciences, Beijing; Zhang Jianbing; Lu Shanliang; Yu Tiemin

    2009-01-01

    Based on the femtosecond accelerator device which was built at the Shanghai Institute of Applied Physics (SINAP), recently a modified far infrared Michelson interferometer has been developed to measure the length of electron bunches via the optical autocorrelation method. Compared with our former normal Michelson interferometer, we use a hollow retroreflector instead of a flat mirror as the reflective mirror. The experimental setup and results of the bunch length measurement will be described in this paper. (authors)

  3. Measurement and restoration of equality in length of the lower limbs in total hip replacement

    Energy Technology Data Exchange (ETDEWEB)

    Hoikka, V.; Paavilainen, T.; Lindholm, T.S.; Turula, K.B.; Ylikoski, M.

    1987-08-01

    Alteration of the length of the lower limb was measured in 39 patients undergoing total hip replacement. Radiographs were taken in the erect posture prior to operation and 6 months postoperatively. The inequality of limb length was measured by the difference between the height of the vertices of the fermoral heads and by the difference between the lowest points of the ischial tuberosities. The change of the length was measured intraoperatively as the difference observed between two reference points: One above the acetabulum and the other on the proximal femur. Good correlation was obtained between the change of the limb length made intraoperatively and the change in the limb length using the ischial tuberosities as reference points; no correlation was observed when the vertices of the femoral heads were the reference points. Inequality of limb length can be radiologically determined before and after total hip arthroplasty. Femoral and prosthetic heads are not good reference points for measurement. The difference in the height of ischial tuberosities demonstrates inequality of limb functional length as it reflects the tilting of the pelvis.

  4. Polarization gating enables sarcomere length measurements by laser diffraction in fibrotic muscle

    Science.gov (United States)

    Young, Kevin W.; Dayanidhi, Sudarshan; Lieber, Richard L.

    2014-11-01

    Sarcomere length is a key parameter commonly measured in muscle physiology since it dictates striated muscle active force. Laser diffraction (LD)-based measurements of sarcomere length are time-efficient and sample a greater number of sarcomeres compared with traditional microscopy-based techniques. However, a limitation to LD techniques is that signal quality is severely degraded by scattering events as photons propagate through tissue. Consequently, sarcomere length measurements are unattainable when the number of scattering events is sufficiently large in muscle tissue with a high scattering probability. This occurs in fibrotic skeletal muscle seen in muscular dystrophies and secondary to tissue trauma, thus eliminating the use of LD to study these skeletal muscle ailments. Here, we utilize polarization gating to extract diffracted signals that are buried in noise created by scattering. Importantly, we demonstrate that polarization-gated laser diffraction (PGLD) enables sarcomere length measurements in muscles from chronically immobilized mice hind limbs; these muscles have a substantial increase of intramuscular connective tissue that scatter light and disable sarcomere length measurements by traditional LD. Further, we compare PGLD sarcomere lengths to those measured by bright field (BF) and confocal microscopy as positive controls and reveal a significant bias of BF but not of confocal microscopy.

  5. The Length of a Pestle: A Class Exercise in Measurement and Statistical Analysis.

    Science.gov (United States)

    O'Reilly, James E.

    1986-01-01

    Outlines the simple exercise of measuring the length of an object as a concrete paradigm of the entire process of making chemical measurements and treating the resulting data. Discusses the procedure, significant figures, measurement error, spurious data, rejection of results, precision and accuracy, and student responses. (TW)

  6. Tyre contact length on dry and wet road surfaces measured by three-axial accelerometer

    Science.gov (United States)

    Matilainen, Mika; Tuononen, Ari

    2015-02-01

    We determined the tyre contact length on dry and wet roads by measuring the accelerations of the inner liner with a three-axial accelerometer. The influence of the tyre pressure, driving velocity, and tread depth on the contact length was studied in both types of road surface conditions. On dry asphalt the contact length was almost constant, regardless of the driving velocity. On wet asphalt the presence of water could be detected even at low driving velocities (e.g. 20 km/h for a worn tyre) as the contact length began to decrease from that found in the dry asphalt situation. In addition to improving the performance of active safety systems and driver warning systems, the contact length information could be beneficial for classifying and studying the aquaplaning behaviour of tyres.

  7. Paediatric renal length measurements from ultrasound and DMSA scans: does clinical practice reflect theoretical normal values?

    International Nuclear Information System (INIS)

    Que, L.; Rutland, M.D.; Hassan, I.M.

    1999-01-01

    Full text: Renal length measurement is a routine part of ultrasound examination in children and those results are plotted on a normogram style graph, so that each child's results are compared to a normal range (mean ± 2 S.D.). Renal length measurements from the posterior oblique views of dimercaptosuccinic acid (DMSA) scans in our department have not always correlated well with the ultrasound measurements on the same patients. Renal lengths from the DMSA scans of 120 patients with apparently normal kidneys were recorded and used to generate a normogram of renal length at different ages (0.5-7 years). This DMSA normogram was compared to the ultrasound (US) normogram used in the Paediatric Radiology Department, and it showed slight differences in renal lengths (3-8 mm), but that the US normogram had smaller coefficients of variation (US = 6.6%, NM 8.3%), implying a 'tighter' normal range. 39 of these patients had DMSA and ultrasound measurements of renal length within 3 months, and these were studied first by calculating the mean and CV values for different age groups, and then by plotting individual renal lengths on the appropriate normograms. The measured data produced much greater variability in the ultrasound measurements than the DTPA measurements, and the individual points produced 4/78 (5.1%) abnormal results for DMSA, but 21/78 (26.9%) abnormal results for ultrasound. Thus, in routine clinical use, using patients with apparently normal kidneys, ultrasound was unable to match the 'normal range' set by their current normogram, but the nuclear medicine showed 5.1% of values outside the normal (DMSA) range, which was completely appropriate for a range of ± 2 standard deviations

  8. The accuracy of axial length measurements in cases of macula-off retinal detachment.

    Science.gov (United States)

    Abou-Shousha, Mohsen; Helaly, Hany Ahmed; Osman, Ihab Mohamed

    2016-04-01

    To assess the accuracy of axial length measurements in cases of macula-off retinal detachment using different methods (optical biometry, A-scan ultrasound, and combined applanation vector-A/B-scan biometry). This prospective clinical study included 100 eyes of 100 patients who underwent vitrectomy alone or phacovitrectomy for macula-off retinal detachment. All patients included signed an informed consent. Preoperative examination of the patients included recording the axial length measurements using optical biometry, A-scan ultrasound, and combined applanation vector-A/B-scan biometry. The mean postoperative IOLMaster axial length after macular reattachment was 26.11 ± 2.91 mm. The mean preoperative IOLMaster axial length with macula-off was 25.32 ± 2.72 mm. The mean preoperative A-scan axial length with macula-off was 25.29 ± 2.80 mm. The mean preoperative vector-A/B-scan axial length with macula-off was 26.03 ± 2.90 mm. The preoperative vector-A/B-scan mean absolute error was 0.59 ± 0.48 D (range, 0.10-2.25 D). Regular methods (optical biometry and A-scan biometry) of measuring the axial length in cases with a detached macula proved to be variable and less accurate. The vector-A/B-scan offered good measurements of the actual axial length in the patients. This was reflected on more accurate postoperative refractive outcome. Copyright © 2016 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  9. 16 CFR 500.12 - Measurement of commodities by length and width, how expressed.

    Science.gov (United States)

    2010-01-01

    ... square foot (929 cm2) be expressed in terms of length and width in linear measure. The customary inch... of 1 square foot (929 cm2) or more, but less than 4 square feet (37.1 dm2), be expressed in terms of... (10.16 cm) or less, the declaration of net quantity shall be expressed in terms of width and length in...

  10. Research on the measurement technology of effective arm length of swing arm profilometer

    Science.gov (United States)

    Chen, Lin; Jing, Hongwei; Wei, Zhongwei; Li, Jie; Cao, Xuedong

    2014-09-01

    When the swing arm profilometer(SAP) measuring the mirror, the effective arm length of SAP which haves an obvious influence on the measurement results of the mirror surface shape needs to be measured accurately. It requires the measurement uncertainty of the effective arm length to reach 10μm in order to meet the measurement requirements, in this paper, we present a kind of technology based on laser tracker to measure the effective arm length of SAP. When the swing arm rotates around the shaft axis of swing arm rotary stage, the probe and two laser tracker balls form three sections of circular arc around the shaft axis of swing arm rotary stage in space. Laser tracker tracks and measures the circular arcs of two laser tracker balls, the center coordinates of the circular plane of circular arc can be calculated by data processing. The linear equation that passes through the two center coordinates is the equation of the shaft axis of rotary stage, the vertical distance from the probe to the shaft axis of rotary stage which can be calculated refer to the equation from the point to the line is the effective arm length. After Matlab simulation, this measurement method can meet the measurement accuracy.

  11. Miniature focal plane mass spectrometer with 1000-pixel modified-CCD detector array for direct ion measurement

    Science.gov (United States)

    Sinha, Mahadeva P.; Wadsworth, Mark

    2005-02-01

    A high performance, focal plane miniature mass spectrometer (MMS) of Mattauch-Herzog geometry with a CCD-based array detector for the direct and simultaneous measurements of different mass ions is described. Miniaturization (10cm×5cm×5cm,395g) was accomplished by using high-energy-product magnet material (Nd-B-Fe alloy) and a high permeability yoke material (V-Co-Fe Alloy) for the fabrication of the magnetic sector. The electrostatic sector was machined from a single piece of machinable ceramic (MACOR). All the components of the analyzer are mounted on a single plate, which facilitate their alignment and make the instrument rugged. The modified-CCD based ion detector array has 1000 elements (20μm×2mm) and was invented in our laboratory. The photosensitive part of the CCD was replaced with a metal-oxide-semiconductor (MOS) capacitor for ion detection. The ion sensing capacitor plates are connected to the CCD gates that are operated in the fill-and spill mode providing a gain in the charge domain for the signal ions and minimizing various noises during measurements. The results reported in this article are the first application of this detector array for direct ion measurement and successfully prove the new technology. The MMS with the array detector can measure masses up to 250u with a unit mass resolution and expected to possess a sensitivity of detecting ˜5ions. The above attributes make MMS suitable for space applications for isotopic and chemical analysis and also for field applications on earth.

  12. Reliability of linear distance measurement for dental implant length with standardized periapical radiographs

    International Nuclear Information System (INIS)

    Wakoh, Mamoru; Harada, Takuya; Otonari, Takamichi

    2006-01-01

    The purpose of this study was to investigate the accuracy of distance measurements of implant length based on periapical radiographs compared with that of other modalities. We carried out an experimental trial to compare precision in distance measurement. Dental implant fixtures were buried in the canine and first molar regions. These were then subjected to periapical (PE) radiography, panoramic (PA) radiography conventional (CV) and medical computed (CT) tomography. The length of the implant fixture on each film was measured by nine observers and degree of precision was statistically analyzed. The precision of both PE radiographs and CT tomograms was closest at the highest level. Standardized PE radiography, in particular, was superior to CT tomography in the first molar region. This suggests that standardized PE radiographs should be utilized as a reliable modality for longitudinal and linear distance measurement, depending on implant length at local implantation site. (author)

  13. Contact Angle Measurement of Small Capillary Length Liquid in Super-repelled State.

    Science.gov (United States)

    Liu, Tingyi Leo; Kim, Chang-Jin Cj

    2017-04-07

    The difficulty of measuring very large contact angles (>150 degrees) has become more relevant with the increased popularity of super-repellent surfaces. Measurement is more difficult for dynamic contact angles, for which theoretical profiles do not fit well, and small capillary length liquids, whose sessile droplets sag by gravity. Here, we expand the issue to the limit by investigating dynamic contact angles of liquids with an extremely small capillary length (contact angles can be measured with a consistent accuracy despite their vastly different capillary lengths if one keeps the lens magnification inversely proportional to the capillary length. Verifying the droplet equator height is a key parameter, we propose a new Bond number defined by the equator height and optical resolution to represent the measurement accuracy of large contact angles. Despite negligible improvement for most liquids today, the proposed approach teaches how to measure very large contact angles with consistent accuracy when any of the liquids in consideration has a capillary length below 1.0 mm.

  14. Air method measurements of apple vessel length distributions with improved apparatus and theory

    Science.gov (United States)

    Shabtal Cohen; John Bennink; Mel Tyree

    2003-01-01

    Studies showing that rootstock dwarfing potential is related to plant hydraulic conductance led to the hypothesis that xylem properties are also related. Vessel length distribution and other properties of apple wood from a series of varieties were measured using the 'air method' in order to test this hypothesis. Apparatus was built to measure and monitor...

  15. Standing Height and its Estimation Utilizing Foot Length Measurements in Adolescents from Western Region in Kosovo

    Directory of Open Access Journals (Sweden)

    Stevo Popović

    2017-10-01

    Full Text Available The purpose of this research is to examine standing height in both Kosovan genders in the Western Region as well as its association with foot length, as an alternative to estimating standing height. A total of 664 individuals (338 male and 326 female participated in this research. The anthropometric measurements were taken according to the protocol of ISAK. The relationships between body height and foot length were determined using simple correlation coefficients at a ninety-five percent confidence interval. A comparison of means of standing height and foot length between genders was performed using a t-test. After that a linear regression analysis were carried out to examine extent to which foot length can reliably predict standing height. Results displayed that Western Kosovan male are 179.71±6.00cm tall and have a foot length of 26.73±1.20cm, while Western Kosovan female are 166.26±5.23cm tall and have a foot length of 23.66±1.06cm. The results have shown that both genders made Western-Kosovans a tall group, a little bit taller that general Kosovan population. Moreover, the foot length reliably predicts standing height in both genders; but, not reliably enough as arm span. This study also confirms the necessity for developing separate height models for each region in Kosovo as the results from Western-Kosovans don’t correspond to the general values.

  16. Effect of different levels of sharpness processing filter on the measurement accuracy of endodontic file length

    Directory of Open Access Journals (Sweden)

    Nastaran Farhadi

    2016-01-01

    Full Text Available Introduction: The present study was undertaken to evaluate the effect of different levels of sharpness processing filter on the accuracy of endodontic file length determination using digital periapical radiography. Materials and Methods: Forty human single-rooted permanent teeth were selected and International Organization for Standardization (ISO #08 K-files were inserted into the root canals of the teeth. The file lengths were measured with a digital caliper as the gold standard. Digital periapical images were obtained using a phosphor storage plate as a detector. Three levels of sharpness tool of Scanora software program version 5.1 was used to produce enhanced images: Sharpen 1 (mild level, Sharpen 2 (moderate level, and Sharpen 3 (high level. Two radiologists and two endodontists measured file lengths on the original and enhanced images. The measurements were compared using repeated measures ANOVA and Bonferroni tests (α = 0.05. Results: There were no significant differences between the measurement accuracy of original images and that of the Sharpen 1 and Sharpen 2 enhanced images (P > 0.05. However, significant differences were found between the measurement accuracy of original and that of the Sharpen 3 enhanced images (P 0.05. Conclusion: The application of mild and moderate levels of sharpness processing filter did not influence the accuracy of endodontic file length determination. However, high-level sharpness processing filter is not recommended due to its unfavorable effects on measurement accuracy.

  17. The use of an individual jig in measuring tooth length changes.

    Science.gov (United States)

    Brezniak, Naphtali; Goren, Shay; Zoizner, Ronen; Dinbar, Ariel; Arad, Arnon; Wasserstein, Atalia; Heller, Moshe

    2004-12-01

    The parallel periapical radiographic technique hides several problems that might affect the image seen on the film. To overcome these problems a special jig with an external wire attached to the tooth surface and parallel to its long axis was suggested. This study examines the accuracy of using an external object for measuring root length differences due to angular changes between the tooth and the film. The rule of three was used for all calculations as a compensating formula. A human central incisor was placed in a special jig. Two different wire lengths (11.8 +/- 0.1 mm and 16 +/- 0.1 mm) were attached to the tooth in six different ways. The tooth was radiographed at four different film to tooth angulations. The tooth and wire lengths were measured on the model itself and directly on the scanned film on a computer monitor. The results reveal that a wire, placed nine mm from the crown and parallel to the long axis of the tooth was the best jig for accurately measuring tooth length changes. Neither palatal nor buccal metal wires, intimately attached to the crown of the tooth, can serve as a tool to measure tooth length changes. The study could not find a way to skip the need for a cephalometric radiograph to verify the parallelism between the wire and the long axis of the tooth for this matter.

  18. Measuring telomere length for the early detection of precursor lesions of esophageal squamous cell carcinoma

    International Nuclear Information System (INIS)

    Lin, Shih-Wen; Wang, Guo-Qing; Wei, Wen-Qiang; Lu, Ning; Taylor, Philip R; Qiao, You-Lin; Dawsey, Sanford M; Abnet, Christian C; Freedman, Neal D; Murphy, Gwen; Risques, Rosana; Prunkard, Donna; Rabinovitch, Peter; Pan, Qin-Jing; Roth, Mark J

    2013-01-01

    Esophageal cancer is the sixth leading cause of cancer death worldwide; current early detection screening tests are inadequate. Esophageal balloon cytology successfully retrieves exfoliated and scraped superficial esophageal epithelial cells, but cytologic reading of these cells has poor sensitivity and specificity for detecting esophageal squamous dysplasia (ESD), the precursor lesion of esophageal squamous cell carcinoma (ESCC). Measuring telomere length, a marker for chromosomal instability, may improve the utility of balloon cytology for detecting ESD and early ESCC. We examined balloon cytology specimens from 89 asymptomatic cases of ESD (37 low-grade and 52 high-grade) and 92 age- and sex-matched normal controls from an esophageal cancer early detection screening study. All subjects also underwent endoscopy and biopsy, and ESD was diagnosed histopathologically. DNA was extracted from the balloon cytology cells, and telomere length was measured by quantitative PCR. A receiver operating characteristic (ROC) curve was plotted for telomere length as a diagnostic marker for high-grade dysplasia. Telomere lengths were comparable among the low- and high-grade dysplasia cases and controls, with means of 0.96, 0.96, and 0.92, respectively. The area under the ROC curve was 0.55 for telomere length as a diagnostic marker for high-grade dysplasia. Further adjustment for subject characteristics, including sex, age, smoking, drinking, hypertension, and body mass index did not improve the use of telomere length as a marker for ESD. Telomere length of esophageal balloon cytology cells was not associated with ESCC precursor lesions. Therefore, telomere length shows little promise as an early detection marker for ESCC in esophageal balloon samples

  19. Quantitative measurement of changes in adhesion force involving focal adhesion kinase during cell attachment, spread, and migration

    International Nuclear Information System (INIS)

    Wu, C.-C.; Su, H.-W.; Lee, C.-C.; Tang, M.-J.; Su, F.-C.

    2005-01-01

    Focal adhesion kinase (FAK) is a critical protein for the regulation of integrin-mediated cellular functions and it can enhance cell motility in Madin-Darby canine kidney (MDCK) cells by hepatocyte growth factor (HGF) induction. We utilized optical trapping and cytodetachment techniques to measure the adhesion force between pico-Newton and nano-Newton (nN) for quantitatively investigating the effects of FAK on adhesion force during initial binding (5 s), beginning of spreading (30 min), spreadout (12 h), and migration (induced by HGF) in MDCK cells with overexpressed FAK (FAK-WT), FAK-related non-kinase (FRNK), as well as normal control cells. Optical tweezers was used to measure the initial binding force between a trapped cell and glass coverslide or between a trapped bead and a seeded cell. In cytodetachment, the commercial atomic force microscope probe with an appropriate spring constant was used as a cyto-detacher to evaluate the change of adhesion force between different FAK expression levels of cells in spreading, spreadout, and migrating status. The results demonstrated that FAK-WT significantly increased the adhesion forces as compared to FRNK cells throughout all the different stages of cell adhesion. For cells in HGF-induced migration, the adhesion force decreased to almost the same level (∼600 nN) regardless of FAK levels indicating that FAK facilitates cells to undergo migration by reducing the adhesion force. Our results suggest FAK plays a role of enhancing cell adhesive ability in the binding and spreading, but an appropriate level of adhesion force is required for HGF-induced cell migration

  20. Interpretation of scanning electron microscope measurements of minority carrier diffusion lengths in semiconductors

    Science.gov (United States)

    Flat, A.; Milnes, A. G.

    1978-01-01

    In scanning electron microscope (SEM) injection measurements of minority carrier diffusion lengths some uncertainties of interpretation exist when the response current is nonlinear with distance. This is significant in epitaxial layers where the layer thickness is not large in relation to the diffusion length, and where there are large surface recombination velocities on the incident and contact surfaces. An image method of analysis is presented for such specimens. A method of using the results to correct the observed response in a simple convenient way is presented. The technique is illustrated with reference to measurements in epitaxial layers of GaAs. Average beam penetration depth may also be estimated from the curve shape.

  1. Competitive Balance Measures in Sports Leagues: The Effects of Variation in Season Length

    OpenAIRE

    P Dorian Owen; Nicholas King

    2013-01-01

    Appropriate measurement of competitive balance is a cornerstone of the economic analysis of professional sports leagues. We examine the distributional properties of the ratio of standard deviations (RSD) of points percentages, the most widely used measure of competitive balance in the sports economics literature, in comparison with other standard-deviation-based measures. Simulation methods are used to evaluate the effects of changes in season length on the distributions of competitive balanc...

  2. Foot length measurements of newborns of high and low risk pregnancies

    Directory of Open Access Journals (Sweden)

    Ana Karina Marques Salge

    Full Text Available Abstract OBJECTIVE Comparing foot length measurements of newborns in high and low risk pregnancies at a public hospital in Goiânia, GO, Brazil. METHOD A cross-sectional study carried out between April, 2013 and May, 2015, with a sample consisting of 180 newborns; 106 infants of women from high-risk pregnancies and 74 of women from low-risk pregnancies. Data were descriptively analyzed. Foot length measurement was performed using a stiff transparent plastic ruler, graduated in millimeters. The length of both feet was measured from the tip of the hallux (big toe to the end of the heel. RESULTS A statistically significant relationship was found between the foot length and newborn’s weight, between the cephalic and thoracic perimeters in the high-risk group and between the cephalic perimeter in the control group. CONCLUSION There is a need for creating cut-off points to identify newborns with intrauterine growth disorders using foot length.

  3. First working group meeting on the minority carrier diffusion length/lifetime measurement: Results of the round robin lifetime/diffusion length tests

    Energy Technology Data Exchange (ETDEWEB)

    Cudzinovic, M; Sopori, B [comp.

    1995-11-01

    As was noted in the cover letter that accompanied the samples, the eleven bare silicon samples were from various manufacturers. Table I lists the codes for the samples and the manufacturer of each sample. It also notes if the sample was single or poly-crystalline. The samples had been polished on one side before being sent out for measurements, but no further processing was done. The participants of the study were asked to measure either the lifetime or diffusion length of each of the samples using their standard procedure. Table II shows the experimental conditions used by the groups who measured diffusion length. All the diffusion length measurements were performed using the Surface Photovoltage method (SPV). Table M shows the experimental conditions for the lifetime measurements. All the lifetime measurements were made using the Photoconductance Decay method (PCD) under low level injection. These tables show the diameter of the spot size used during the measurement (the effective sampling area), the locations where measurements were taken, and the number of measurements taken at each location. Table N shows the results of the measurements. The table is divided into diffusion length and lifetime measurements for each sample. The values listed are the average values reported by each group. One of the immediate artifacts seen in the data is the large variation in the lifetime measurements. The values from MIT and Mobil are generally close. However, the measurements from NCSU are typically an order of magnitude lower.

  4. Ultrasonographic measurement of fetal foot length and femur/foot length ratio in second trimester of normal pregnancy tn Korean women

    International Nuclear Information System (INIS)

    Ji, Eun Kyung

    2001-01-01

    The aim of this study was to determine, using prenatal ultrasongraphy, normal fetal foot length and the femur length ratio during the second trimester of a normal pregnancy in Korean women. From May to July 1999, and in September of the same year, 1018 normal Korean singleton pregnancies showing no abnormality on prenatal sonograms were included in this study. The gestational age ranged from 19 to 30 weeks. Femur and foot length were measured by one radiologist. Regression analysis was performed for foot length and gestational age, and the mean value of the femur/foot length ratio and 95th percentile confidence interval of that mean value were calculated. The data obtained was compared with that obtained from caucasians. Foot length correlated with gestational age (r 2 =0.87, ρ value= 0.0001). The regression formula was as follows; Gestational age (days) = 70.98-2.15 X foot length (mm). Mean foot length at each gestational week was not different from the corresponding figure for Cancasians. The mean (±SD) value of the femur/foot length ratio was 0.96 (±0.05) and the 95 th percentile confidence interval of that mean value was 0.96± 0.000301, figures which are significantly lower than those for Caucasians. Fetal foot length during the second trimester of a normal pregnancy in Korean women is a reliable parameter for use in the assessment of gestational age. In our study the fetal foot length was not different from that of caucasians, while the femur/foot length ratio was lower than the value in that group. The nomogram depicted in of this study will serve as a useful adjunct in the screening of chromosomal abnormality or skeletal dysplasia among Koreans

  5. Measuring single-walled carbon nanotube length distributions from diffusional trajectories.

    Science.gov (United States)

    Streit, Jason K; Bachilo, Sergei M; Naumov, Anton V; Khripin, Constantine; Zheng, Ming; Weisman, R Bruce

    2012-09-25

    A new method is demonstrated for measuring the length distributions of dispersed single-walled carbon nanotube (SWCNT) samples by analyzing diffusional motions of many individual nanotubes in parallel. In this method, termed "length analysis by nanotube diffusion" (LAND), video sequences of near-IR fluorescence microscope images showing many semiconducting SWCNTs are recorded and processed by custom image analysis software. This processing locates the individual nanotubes, tracks their translational trajectories, computes the corresponding diffusion coefficients, and converts those values to nanotube lengths. The deduced length values are then compiled into a histogram of lengths present in the sample. By using specific excitation wavelengths and emission filters, this analysis is performed on selected (n,m) structural species. The new LAND method has been found to give distributions in very good agreement with those obtained by conventional AFM analysis of the same samples. Because it is fluorescence-based, LAND monitors only semiconducting, relatively pristine SWCNTs. However, it is less sensitive to artifacts from impurities and bundled nanotubes than AFM or light scattering methods. In addition, samples can be analyzed with less time and operator attention than by AFM. LAND is a promising alternative method for characterizing length distributions of SWCNTs in liquid suspension.

  6. Stability of measures from children's interviews: the effects of time, sample length, and topic.

    Science.gov (United States)

    Heilmann, John; DeBrock, Lindsay; Riley-Tillman, T Chris

    2013-08-01

    The purpose of this study was to examine the reliability of, and sources of variability in, language measures from interviews collected from young school-age children. Two 10-min interviews were collected from 20 at-risk kindergarten children by an examiner using a standardized set of questions. Test-retest reliability coefficients were calculated for 8 language measures. Generalizability theory (G-theory) analyses were completed to document the variability introduced into the measures from the child, session, sample length, and topic. Significant and strong reliability correlation coefficients were observed for most of the language sample measures. The G-theory analyses revealed that most of the variance in the language measures was attributed to the child. Session, sample length, and topic accounted for negligible amounts of variance in most of the language measures. Measures from interviews were reliable across sessions, and the sample length and topic did not have a substantial impact on the reliability of the language measures. Implications regarding the clinical feasibility of language sample analysis for assessment and progress monitoring are discussed.

  7. Pedestrian Stride Length Estimation from IMU Measurements and ANN Based Algorithm

    Directory of Open Access Journals (Sweden)

    Haifeng Xing

    2017-01-01

    Full Text Available Pedestrian dead reckoning (PDR can be used for continuous position estimation when satellite or other radio signals are not available, and the accuracy of the stride length measurement is important. Current stride length estimation algorithms, including linear and nonlinear models, consider a few variable factors, and some rely on high precision and high cost equipment. This paper puts forward a stride length estimation algorithm based on a back propagation artificial neural network (BP-ANN, using a consumer-grade inertial measurement unit (IMU; it then discusses various factors in the algorithm. The experimental results indicate that the error of the proposed algorithm in estimating the stride length is approximately 2%, which is smaller than that of the frequency and nonlinear models. Compared with the latter two models, the proposed algorithm does not need to determine individual parameters in advance if the trained neural net is effective. It can, thus, be concluded that this algorithm shows superior performance in estimating pedestrian stride length.

  8. Direct measurement of the triplet exciton diffusion length in organic semiconductors

    NARCIS (Netherlands)

    Mikhnenko, O.V.; Ruiter, R.; Blom, P.W.M.; Loi, M.A.

    2012-01-01

    We present a new method to measure the triplet exciton diffusion length in organic semiconductors. N,N′-di-[(1-naphthyl)-N,N′-diphenyl]-1,1′-biphenyl)-4,4′-diamine (NPD) has been used as a model system. Triplet excitons are injected into a thin film of NPD by a phosphorescent thin film, which is

  9. Measuring retinal blood flow in rats using Doppler optical coherence tomography without knowing eyeball axial length

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Wenzhong; Yi, Ji; Chen, Siyu [Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60208 (United States); Jiao, Shuliang [Department of Biomedical Engineering, Florida International University, Miami, Florida 33174 (United States); Zhang, Hao F., E-mail: hfzhang@northwestern.edu [Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60208 and Department of Ophthalmology, Northwestern University, Chicago, Illinois 60611 (United States)

    2015-09-15

    Purpose: Doppler optical coherence tomography (OCT) is widely used for measuring retinal blood flow. Existing Doppler OCT methods require the eyeball axial length, in which empirical values are usually used. However, variations in the axial length can create a bias unaccounted for in the retinal blood flow measurement. The authors plan to develop a Doppler OCT method that can measure the total retinal blood flow rate without requiring the eyeball axial length. Methods: The authors measured the retinal blood flow rate using a dual-ring scanning protocol. The small and large scanning rings entered the eye at different incident angles (small ring: 4°; large ring: 6°), focused on different locations on the retina, and detected the projected velocities/phase shifts along the probing beams. The authors calculated the ratio of the projected velocities between the two rings, and then used this ratio to estimate absolute flow velocity. The authors tested this method in both Intralipid phantoms and in vivo rats. Results: In the Intralipid flow phantom experiments, the preset and measured flow rates were consistent with the coefficient of determination as 0.97. Linear fitting between preset and measured flow rates determined the fitting slope as 1.07 and the intercept as −0.28. In in vivo rat experiments, the measured average total retinal blood flow was 7.02 ± 0.31μl/min among four wild-type rats. The authors’ measured flow rates were consistent with results in the literature. Conclusions: By using a dual-ring scanning protocol with carefully controlled incident angle difference between the two scanning rings in Doppler OCT, the authors demonstrated that it is feasible to measure the absolute retinal blood flow without knowing the eyeball axial length.

  10. Differentiation of multiple sclerosis plaques, subacute cerebral ischaemic infarcts, focal vasogenic oedema and lesions of subcortical arteriosclerotic encephalopathy using magnetisation transfer measurements

    International Nuclear Information System (INIS)

    Reidel, M.A.; Stippich, C.; Heiland, S.; Haehnel, S.; Storch-Hagenlocher, B.; Jansen, O.

    2003-01-01

    Although multiple sclerosis (MS) plaques, subacute cerebral ischaemic infarcts, focal vasogenic brain oedema, and subcortical arteriosclerotic encephalopathy (SAE) often have typical radiological patterns, they are sometimes difficult to distinguish from each other. Our aim was to determine whether they can be differentiated by magnetisation transfer (MT) measurements. We measured MT ratios (MTR) in ten patients with plaques of MS, 11 with subacute ischaemic infarcts, 12 with focal vasogenic oedema, and ten with lesions of SAE and compared the mean MTRs statistically. The MTR of normal white matter was 47.3%; the lowest MTR was found in plaques of MS (mean 26.4%). With the exception of vasogenic oedema and subacute cerebral ischaemic infarcts the mean MTRs were significantly different between all groups. MT measurements can provide additional information for the differentiation of these conditions, but we could not distinguish vasogenic oedema from subacute cerebral ischaemic infarcts. (orig.)

  11. Length determination on industrial polymer parts from measurement performed under transient temperature conditions

    DEFF Research Database (Denmark)

    Dalla Costa, Giuseppe; Madruga, Daniel González; De Chiffre, Leonardo

    2016-01-01

    the cooling phase, from 27 °C to 20 °C approximately. The length variation was measured by means of an inductive probe and the temperature with an RTD surface sensor. The frame of the system was composed by elements in Zerodur and Invar to minimize the thermal deformations of the structure. Uniform...... temperature in the part was assumed. The reference length at 20 °C (L20) was calculated with an a posteriori regression of the data from the complete cooling curve. A prediction of L20 was then performed exploiting partial segments of the curve. Several segments with different time spans and starting points...

  12. Measuring the attenuation length of water in the CHIPS-M water Cherenkov detector

    Energy Technology Data Exchange (ETDEWEB)

    Amat, F.; Bizouard, P. [Aix Marseille University Saint-Jerome, 13013 Marseille (France); Bryant, J. [Department of Physics and Astronomy, UCL, Gower St, London WC1E 6BT (United Kingdom); Carroll, T.J.; Rijck, S. De [Department of Physics, University of Texas at Austin, Austin, TX 78712 (United States); Germani, S. [Department of Physics and Astronomy, UCL, Gower St, London WC1E 6BT (United Kingdom); Joyce, T. [School of Physics and Astronomy, University of Minnesota, Minneapolis, MN 55455 (United States); Kriesten, B. [Department of Physics, College of William & Mary, Williamsburg, VA 23187 (United States); Marshak, M.; Meier, J. [School of Physics and Astronomy, University of Minnesota, Minneapolis, MN 55455 (United States); Nelson, J.K. [Department of Physics, College of William & Mary, Williamsburg, VA 23187 (United States); Perch, A.J.; Pfützner, M.M. [Department of Physics and Astronomy, UCL, Gower St, London WC1E 6BT (United Kingdom); Salazar, R. [Department of Physics, University of Texas at Austin, Austin, TX 78712 (United States); Thomas, J., E-mail: jennifer.thomas@ucl.ac.uk [Department of Physics and Astronomy, UCL, Gower St, London WC1E 6BT (United Kingdom); Department of Physics, University of Wisconsin, Madison, WI 53706 (United States); Trokan-Tenorio, J. [Department of Physics, University of Wisconsin, Madison, WI 53706 (United States); Vahle, P. [Department of Physics, College of William & Mary, Williamsburg, VA 23187 (United States); Wade, R. [Avenir Consulting, Abingdon, Oxfordshire (United Kingdom); Wendt, C. [Department of Physics, University of Wisconsin, Madison, WI 53706 (United States); Whitehead, L.H. [Department of Physics and Astronomy, UCL, Gower St, London WC1E 6BT (United Kingdom); and others

    2017-02-01

    The water at the proposed site of the CHIPS water Cherenkov detector has been studied to measure its attenuation length for Cherenkov light as a function of filtering time. A scaled model of the CHIPS detector filled with water from the Wentworth 2W pit, proposed site of the CHIPS deployment, in conjunction with a 3.2 m vertical column filled with this water, was used to study the transmission of 405 nm laser light. Results consistent with attenuation lengths of up to 100 m were observed for this wavelength with filtration and UV sterilization alone.

  13. Measurement of the diffusion length of thermal neutrons in the beryllium oxide

    International Nuclear Information System (INIS)

    Koechlin, J.C.; Martelly, J.; Duggal, V.P.

    1955-01-01

    The diffusion length of thermal neutrons in the beryllium oxide has been obtained while studying the spatial distribution of the neutrons in a massive parallelepiped of this matter placed before the thermal column of the reactor core of Saclay. The mean density of the beryllium oxide (BeO) is 2,95 gr/cm 3 , the mean density of the massif is 2,92 gr/cm 3 . The value of the diffusion length, deducted of the done measures, is: L = 32,7 ± 0,5 cm (likely gap). Some remarks are formulated about the influence of the spectral distribution of the neutrons flux used. (authors) [fr

  14. Photon path length distributions for cloudy skies – oxygen A-Band measurements and model calculations

    Directory of Open Access Journals (Sweden)

    O. Funk

    Full Text Available This paper addresses the statistics underlying cloudy sky radiative transfer (RT by inspection of the distribution of the path lengths of solar photons. Recent studies indicate that this approach is promising, since it might reveal characteristics about the diffusion process underlying atmospheric radiative transfer (Pfeilsticker, 1999. Moreover, it uses an observable that is directly related to the atmospheric absorption and, therefore, of climatic relevance. However, these studies are based largely on the accuracy of the measurement of the photon path length distribution (PPD. This paper presents a refined analysis method based on high resolution spectroscopy of the oxygen A-band. The method is validated by Monte Carlo simulation atmospheric spectra. Additionally, a new method to measure the effective optical thickness of cloud layers, based on fitting the measured differential transmissions with a 1-dimensional (discrete ordinate RT model, is presented. These methods are applied to measurements conducted during the cloud radar inter-comparison campaign CLARE’98, which supplied detailed cloud structure information, required for the further analysis. For some exemplary cases, measured path length distributions and optical thicknesses are presented and backed by detailed RT model calculations. For all cases, reasonable PPDs can be retrieved and the effects of the vertical cloud structure are found. The inferred cloud optical thicknesses are in agreement with liquid water path measurements.

    Key words. Meteorology and atmospheric dynamics (radiative processes; instruments and techniques

  15. Photon path length distributions for cloudy skies – oxygen A-Band measurements and model calculations

    Directory of Open Access Journals (Sweden)

    O. Funk

    2003-03-01

    Full Text Available This paper addresses the statistics underlying cloudy sky radiative transfer (RT by inspection of the distribution of the path lengths of solar photons. Recent studies indicate that this approach is promising, since it might reveal characteristics about the diffusion process underlying atmospheric radiative transfer (Pfeilsticker, 1999. Moreover, it uses an observable that is directly related to the atmospheric absorption and, therefore, of climatic relevance. However, these studies are based largely on the accuracy of the measurement of the photon path length distribution (PPD. This paper presents a refined analysis method based on high resolution spectroscopy of the oxygen A-band. The method is validated by Monte Carlo simulation atmospheric spectra. Additionally, a new method to measure the effective optical thickness of cloud layers, based on fitting the measured differential transmissions with a 1-dimensional (discrete ordinate RT model, is presented. These methods are applied to measurements conducted during the cloud radar inter-comparison campaign CLARE’98, which supplied detailed cloud structure information, required for the further analysis. For some exemplary cases, measured path length distributions and optical thicknesses are presented and backed by detailed RT model calculations. For all cases, reasonable PPDs can be retrieved and the effects of the vertical cloud structure are found. The inferred cloud optical thicknesses are in agreement with liquid water path measurements. Key words. Meteorology and atmospheric dynamics (radiative processes; instruments and techniques

  16. Lifetime and diffusion length measurements on silicon material and solar cells. [Intentionally doped with impurities

    Energy Technology Data Exchange (ETDEWEB)

    Othmer, S.; Chen, S.C.

    1977-01-01

    Experimental methods were evaluated for the determination of lifetime and diffusion length in silicon intentionally doped with potentially lifetime-degrading impurities found in metallurgical grade silicon, impurities which may be residual in low-cost silicon intended for use in terrestrial flat-plat arrays. Results obtained by these methods were compared for mutual consistency. Lifetime measurements were made using a steady-state photoconductivity method, which was compared with a photoconductivity decay technique. Diffusion length determinations were made using short-circuit current measurements under penetrating illumination. This method was compared with a direct measurement of diffusion length using a scanning electron microscope. Mutual consistency among all experimental methods was verified, but steady-state photoconductivity was found preferable to photoconductivity decay at short lifetimes and in the presence of traps. The effects of a number of impurities on lifetime in bulk material, and on diffusion length in cells fabricated from this material, were determined. Results were compared with those obtained by others on the same material and devices using different techniques. General agreement was found in terms of the hierarchy of impurities which degrade the lifetime.

  17. Air method measurements of apple vessel length distributions with improved apparatus and theory.

    Science.gov (United States)

    Cohen, Shabtai; Bennink, John; Tyree, Mel

    2003-08-01

    Studies showing that rootstock dwarfing potential is related to plant hydraulic conductance led to the hypothesis that xylem properties are also related. Vessel length distribution and other properties of apple wood from a series of varieties were measured using the 'air method' in order to test this hypothesis. Apparatus was built to measure and monitor conductivity to air of fresh wood segments of different lengths. Theory for determining vessel length distribution was improved to give a single parameter uni-modal vessel length probability density function. The function, derived by combining the exponential extinction (with extinction coefficient k) of wood conductivity to air (C) as wood length (x) increases (i.e. C=Co exp (-kx)) with the differential double difference formula, is Px=xxk2 exp (-kx), where Px is the fraction of vessels of length x. The main parameter of the distribution, k, was found to be the inverse of the mode of the distribution, i.e. the most common vessel length, Lo. Lo for ten apple rootstock and scion varieties varied from 5.6+/-0.1 cm (+/-SE) for MM.111 to 9.0+/-1.0 for Prunifolia (P <0.05). Average maximum vessel length was approximately 50 cm, and differences were not significant. Effective vessel radii ranged from 14 for Prunifolia to 24.3+/-0.7 micro m for M.26, with standard errors less than 12% of the mean. Specific conductivity of a 15 cm wood segment ranged from 2x109-4) to 1.6+/-0.2x10(-2) dm3 s(-1) kPa(-1) m(-1) for maruba and M.26, respectively, with standard errors up to 63% of the mean. Vessel density at the air entry point ranged from 18+/-3 to 42+/-6 vessels mm-2 for M.26 and MM.106, respectively, with standard errors as high as 89% of the mean. It was concluded that there is no general relationship between the wood properties investigated and rootstock size class, and that plasticity increases from vessel lengths to radii to specific conductivity and vessel densities.

  18. Ex vivo radiographic tooth length measurements with the reference sphere method (RSM).

    Science.gov (United States)

    Roeder, Felix; Brüllmann, Dan; d'Hoedt, Bernd; Schulze, Ralf

    2010-12-01

    A reference-based radiographic "reference sphere method" (RSM) for accurate length measurements in (dental) projection radiographs for the assessment of tooth length in dry human mandible sections is evaluated. RSM determines the depth coordinates of reference spheres placed in the object plane from the elliptical distortion of their shadows. Two segments (one canine and one molar) of dry human mandibles were exposed 95 times at different angulations (0-40°) on a dental charge-coupled device receptor. Three steel spheres (diameters d (1) = 2.00 mm, d (2) = 3.00 mm) were attached roughly coplanar with the tooth's main axis. Radiographs were assessed once by visual inspection plus manual landmark identification with a mouse-driven cursor. The results were compared to the true tooth length assessed after extraction and to a conventional method (C), i.e., the rule of proportion based on magnification of the sphere shadows. Mean relative length error was 2.28% (d (1)) and 0.46% (d (2)) for RSM and -13.58% (d (1)) and -9.90% (d (2)) for C. For both methods, length errors were significantly (p correction of objects coplanar with the reference spheres. Remaining errors are mainly due to incorrect landmark definition. In our setup, these were exaggerated by the visual/manual image-evaluation process. Automated image analysis has been shown for similar tasks to minimize these errors considerably.

  19. The influence of humidity on accuracy length measurement on polymer parts

    DEFF Research Database (Denmark)

    Madruga, Daniel González; Alexiou, A.; Dalla Costa, Giuseppe

    2016-01-01

    The work deals with an experimental study of the influence of humidity on accurate length measurements on ABS parts. Polymer parts absorb water from the ambient until they reach hygroscopic equilibrium. Water content causes an expansion of the polymer part. The relationship between the water...... content and this expansion has been barely studied, especially from a metrology point of view including its contribution to the measurement uncertainty. The experimental set-up includes a humidity chamber, an invar fixture with 8 inductive probes and a scale. The humidity chamber was used to create...... parts were measured at 5 levels of relative humidity from 50 %RH to 90 %RH, and constant temperature, 20 ±0.2˚C. Water content equilibrium with the ambient was achieved at each level by acclimatization of the parts for 24 hours. An average length variation over the humidity range of 15 μm was found...

  20. L-shaped caliper for limb length measurement during total hip arthroplasty.

    Science.gov (United States)

    Shiramizu, K; Naito, M; Shitama, T; Nakamura, Y; Shitama, H

    2004-09-01

    The existing methods of assessing limb lengthening during total hip arthroplasty (THA) are prone to error because the measurements are not parallel to the limb lengthening axis. In order to address this, we designed a caliper to estimate limb lengthening during THA and evaluated its accuracy compared with our previous device, the straight caliper. Limb lengths were measured in 100 patients. The L-shaped caliper was used in 50 cases and the straight caliper in 50. The correlation between intra-operative and post-operative radiographic measurements was significantly improved using the L-shaped device (p < 0.0001, r = 0.934). This method was extremely accurate in predicting changes in limb length due to surgery.

  1. Two- and three-dimensional CT measurements of urinary calculi length and width: a comparative study.

    Science.gov (United States)

    Lidén, Mats; Thunberg, Per; Broxvall, Mathias; Geijer, Håkan

    2015-04-01

    The standard imaging procedure for a patient presenting with renal colic is unenhanced computed tomography (CT). The CT measured size has a close correlation to the estimated prognosis for spontaneous passage of a ureteral calculus. Size estimations of urinary calculi in CT images are still based on two-dimensional (2D) reformats. To develop and validate a calculus oriented three-dimensional (3D) method for measuring the length and width of urinary calculi and to compare the calculus oriented measurements of the length and width with corresponding 2D measurements obtained in axial and coronal reformats. Fifty unenhanced CT examinations demonstrating urinary calculi were included. A 3D symmetric segmentation algorithm was validated against reader size estimations. The calculus oriented size from the segmentation was then compared to the estimated size in axial and coronal 2D reformats. The validation showed 0.1 ± 0.7 mm agreement against reference measure. There was a 0.4 mm median bias for 3D estimated calculus length compared to 2D (P calculus in axial and coronal reformats becomes underestimated compared to 3D if its orientation is not aligned to the image planes. Future studies aiming to correlate calculus size with patient outcome should use a calculus oriented size estimation. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  2. Is socioeconomic status associated with biological aging as measured by telomere length?

    Science.gov (United States)

    Robertson, Tony; Batty, G David; Der, Geoff; Fenton, Candida; Shiels, Paul G; Benzeval, Michaela

    2013-01-01

    It has been hypothesized that one way in which lower socioeconomic status (SES) affects health is by increasing the rate of biological aging. A widely used marker of biological aging is telomere length. Telomeres are structures at the ends of chromosomes that erode with increasing cell proliferation and genetic damage. We aimed to identify, through systematic review and meta-analysis, whether lower SES (greater deprivation) is associated with shorter telomeres. Thirty-one articles, including 29 study populations, were identified. We conducted 3 meta-analyses to compare the telomere lengths of persons of high and low SES with regard to contemporaneous SES (12 study populations from 10 individual articles), education (15 study populations from 14 articles), and childhood SES (2 study populations from 2 articles). For education, there was a significant difference in telomere length between persons of high and low SES in a random-effects model (standardized mean difference (SMD) = 0.060, 95% confidence interval (CI): 0.002, 0.118; P = 0.042), although a range of sensitivity analyses weakened this association. There was no evidence for an association between telomere length and contemporaneous SES (SMD = 0.104, 95% CI: -0.027, 0.236; P = 0.119) or childhood SES (SMD = -0.037, 95% CI: -0.143, 0.069; P = 0.491). These results suggest weak evidence for an association between SES (as measured by education) and biological aging (as measured by telomere length), although there was a lack of consistent findings across the SES measures investigated here. © The Author 2012. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health.

  3. Core Length and Spray Width Measurements in Shear Coaxial Rocket Injectors from X-ray Radiography Measurements

    Science.gov (United States)

    2015-05-01

    Rocket Injectors from X-ray Radiography Measurements 5a. CONTRACT NUMBER In-House 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) M. D...behavior. To overcome the problems of multiple scattering, the near-injector region was studied using x-ray radiography at Argonne National Laboratory’s...and understand more clearly what this term means. Three methods are explored to measure core length from x-ray radiography data and are compared to

  4. Core Length and Spray Width Measurements in Shear Coaxial Injectors from X-ray Radiography Measurements (Briefing Charts)

    Science.gov (United States)

    2015-04-01

    Injectors from X- ray Radiography Measurements 5a. CONTRACT NUMBER In-House 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d...behavior. To overcome the problems of multiple scattering, the near-injector region was studied using x-ray radiography at Argonne National...length” and understand more clearly what this term means. Three methods are explored to measure core length from x-ray radiography data and are

  5. Analysis of impedance measurements of a suspension of microcapsules using a variable length impedance measurement cell

    Directory of Open Access Journals (Sweden)

    Dejan Krizaj

    2012-10-01

    Full Text Available Electrical impedance measurements of the suspensions have to take into account the double layer impedance that is due to a very thin charged layer formed at the electrode-electrolite interface. A dedicated measuring cell that enables variation of the distance between the electrodes was developed for investigation of electrical properties of suspensions using two electrode impedance measurements. By varying the distance between the electrodes it is possible to separate the double layer and the suspension impedance from the measured data. From measured and extracted impedances electrical lumped models have been developed. The error of non inclusion of the double layer impedance has been analyzed. The error depends on the frequency of the measurements as well as on the distance between the electrodes.

  6. Dynamic Length Metrology (DLM) for measurements with sub-micrometre uncertainty in a production environment

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Hansen, Hans Nørgaard; Hattel, Jesper Henri

    2016-01-01

    by mathematical or numerical modelling of the thermo-mechanical effects. It is hereby possible concurrently to predict condition-specific material properties as well as part dimensions at any point, time, temperature, humidity, etc. Knowing all systematic errors and influencing factors, and their combined effect......, on a given length, it is possible to calculate the corrected length at 20°C, zero measuring force, etc. An estimation of the measurement uncertainty U can be obtained following the guidelines of the GUM, dimensional values and their uncertainties being the final result of the analysis. Preliminary...... investigations have indicated that the approach is viable, either using analytical modelling or FEM. An expanded uncertainty (k=2) lower than 0.4 μm was achieved using a steel gauge block as workpiece....

  7. Non-dispersive method for measuring longitudinal neutron coherence length using high frequency cold neutron pulser

    International Nuclear Information System (INIS)

    Kawai, T.; Tasaki, S.; Ebisawa, T.; Hino, M.; Yamazaki, D.; Achiwa, N.

    1999-01-01

    Complete text of publication follows. A non-dispersive method is proposed for measuring the longitudinal coherence length of a neutron using a high frequency cold neutron pulser (hf-CNP) placed between two multilayer spin splitters (MSS) which composes the cold neutron spin interferometer. Two spin eigenstates of a neutron polarized x-y plane are split non-dispersively and longitudinally in time by the hf-CNP which could reflect two components alternatively in time. The reduction of the visibility of interference fringes after being superposed by the second MSS is measured as a function of the frequency of the pulser by TOF method. From the zero visibility point obtained by extrapolation one could obtain the longitudinal coherence length of the neutron. (author)

  8. Influence of DNA extraction methods on relative telomere length measurements and its impact on epidemiological studies.

    Science.gov (United States)

    Raschenberger, Julia; Lamina, Claudia; Haun, Margot; Kollerits, Barbara; Coassin, Stefan; Boes, Eva; Kedenko, Ludmilla; Köttgen, Anna; Kronenberg, Florian

    2016-05-03

    Measurement of telomere length is widely used in epidemiologic studies. Insufficient standardization of the measurements processes has, however, complicated the comparison of results between studies. We aimed to investigate whether DNA extraction methods have an influence on measured values of relative telomere length (RTL) and whether this has consequences for epidemiological studies. We performed four experiments with RTL measurement in quadruplicate by qPCR using DNA extracted with different methods: 1) a standardized validation experiment including three extraction methods (magnetic-particle-method EZ1, salting-out-method INV, phenol-chloroform-isoamyl-alcohol PCI) each in the same 20 samples demonstrated pronounced differences in RTL with lowest values with EZ1 followed by INV and PCI-isolated DNA; 2) a comparison of 307 samples from an epidemiological study showing EZ1-measurements 40% lower than INV-measurements; 3) a matching-approach of two similar non-diseased control groups including 143 pairs of subjects revealed significantly shorter RTL in EZ1 than INV-extracted DNA (0.844 ± 0.157 vs. 1.357 ± 0.242); 4) an association analysis of RTL with prevalent cardiovascular disease detected a stronger association with INV than with EZ1-extracted DNA. In summary, DNA extraction methods have a pronounced influence on the measured RTL-values. This might result in spurious or lost associations in epidemiological studies under certain circumstances.

  9. Fiber length measurement from the determination of juvenile wood in Eucalyptus citriodora

    OpenAIRE

    Calonego, Fred Willians [UNESP; Severo, Elias Taylor Durgante [UNESP; Assi, Priscila Paula [UNESP

    2005-01-01

    The juvenile wood has peculiar characteristics from the anatomical structure and physical-mechanical properties, considering these aspects the knowledge of the wood is essential for wood adequate utilization. The aim of this work was to determinate the zone of juvenile wood of pith-bark direction in Eucalyptus citriodora. The juvenile and mature wood zones were determined across fiber length measurement in various height in the tree stem. Results showed that juvenile wood zone occurs approxim...

  10. Interpretation of Core Length in Shear Coaxial Rocket Injectors from X-ray Radiography Measurements

    Science.gov (United States)

    2014-06-01

    technique , X- ray radiography , to the well-studied problem of core length of shear coaxial jets is an important step in understanding the strengths...role, as is evident in Fig. 8a for the SC1. Unfortunately the X-ray radiography technique cannot distinguish between intact liquid in the jet and...Shear Coaxial Rocket Injectors from X-ray Radiography Measurements 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT

  11. Cervical Length & Leading Placental Edge to Internal OS Measurements - TA vs TV

    DEFF Research Database (Denmark)

    Westerway, Sue Campbell; Pedersen, Lars Henning; Hyett, Jon

    Brief Description of the Purpose of the Study: To compare cervical length/leading placental edge from the internal cervical os measurements obtained by both transabdominal (TA) and transvaginal (TV) approach and to assess intra / inter-observer variation for these measurements. Methods: Cross......, both overall and stratified by gestation. Test characteristics were calculated for cervix,25mm. On twenty of the above studies, two observers measured each of the param- eters at least twice. Intra / inter-observer error was the mean deviation calculated as a percentage of the mean measurement. Main...... Results: Overall, TA measurements of both cervix and placental edge position were statistically different from measure- ments obtained TV. In second trimester, the TA cervix estimate was 2.7 mm , (95% CI 1.8-3.6) TV estimate. .24 weeks gestation, the difference between the two methods for cervix...

  12. The accuracy of the radiographic method in root canal length measurement

    International Nuclear Information System (INIS)

    Jo, Eun Young; Park, Chang Seo

    1998-01-01

    For the successful endodontic treatment, root canal should be cleaned thoroughly by accurate mechanical and chemical canal preparation and sealed completely with canal filling material without damaging the periapical tissues. The accuracy of the root canal length measurement is a prerequisite for the success of the endodontic treatment, and the root canal length is often determined by the standard periapical radiographs and digital tactile sense. In this study, the accuracy and the clinical usefulness of Digora, an intraoral digital imaging processor and the conventional standard radiographs were compared by measuring the length from the top of the file to the root apex. 30 single rooted premolars were invested in a uniformly sized blocks and No.25 K-file was inserted into and fixed in each canal. Each block was placed in equal distance and position to satisfy the principle of the bisecting angle and paralleling techniques and Digora system's image and standard periapical radiographs were taken. Each radiograph was examined by 3 different observers by measuring the length from top of the file to the root apex and each data was compared and analyzed. The results were as follows; 1. In the bisecting angle technique, the average difference between the Digora system and standard periapical radiograph was 0.002 mm and the standard deviation was 0.341 mm which showed no statistically significant difference between the two systems (p>0.05). Also, in the paralleling technique, the average difference between these two system was 0.007 mm and the standard deviation was 0.323 mm which showed no statistically significant difference between the two systems (p>0.05). 2. In Digora system, the average difference between the bisecting angle and paralleling technique was -0.336 mm and the standard deviation was 0.472 mm which showed a statistically significant difference between the two techniques (p 0.05). In conclusion, the determination of the root canal length by using the

  13. The accuracy of the radiographic method in root canal length measurement

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Eun Young; Park, Chang Seo [Dept. of Dental Radiology, College of Dentistry, Yonsei University, Seoul (Korea, Republic of)

    1998-08-15

    For the successful endodontic treatment, root canal should be cleaned thoroughly by accurate mechanical and chemical canal preparation and sealed completely with canal filling material without damaging the periapical tissues. The accuracy of the root canal length measurement is a prerequisite for the success of the endodontic treatment, and the root canal length is often determined by the standard periapical radiographs and digital tactile sense. In this study, the accuracy and the clinical usefulness of Digora, an intraoral digital imaging processor and the conventional standard radiographs were compared by measuring the length from the top of the file to the root apex. 30 single rooted premolars were invested in a uniformly sized blocks and No.25 K-file was inserted into and fixed in each canal. Each block was placed in equal distance and position to satisfy the principle of the bisecting angle and paralleling techniques and Digora system's image and standard periapical radiographs were taken. Each radiograph was examined by 3 different observers by measuring the length from top of the file to the root apex and each data was compared and analyzed. The results were as follows; 1. In the bisecting angle technique, the average difference between the Digora system and standard periapical radiograph was 0.002 mm and the standard deviation was 0.341 mm which showed no statistically significant difference between the two systems (p>0.05). Also, in the paralleling technique, the average difference between these two system was 0.007 mm and the standard deviation was 0.323 mm which showed no statistically significant difference between the two systems (p>0.05). 2. In Digora system, the average difference between the bisecting angle and paralleling technique was -0.336 mm and the standard deviation was 0.472 mm which showed a statistically significant difference between the two techniques (p<0.05). Also, 3. In Digora system and the standard periapical radiographs

  14. Effect of length of measurement period on accuracy of predicted annual heating energy consumption of buildings

    International Nuclear Information System (INIS)

    Cho, Sung-Hwan; Kim, Won-Tae; Tae, Choon-Soeb; Zaheeruddin, M.

    2004-01-01

    This study examined the temperature dependent regression models of energy consumption as a function of the length of the measurement period. The methodology applied was to construct linear regression models of daily energy consumption from 1 day to 3 months data sets and compare the annual heating energy consumption predicted by these models with actual annual heating energy consumption. A commercial building in Daejon was selected, and the energy consumption was measured over a heating season. The results from the investigation show that the predicted energy consumption based on 1 day of measurements to build the regression model could lead to errors of 100% or more. The prediction error decreased to 30% when 1 week of data was used to build the regression model. Likewise, the regression model based on 3 months of measured data predicted the annual energy consumption within 6% of the measured energy consumption. These analyses show that the length of the measurement period has a significant impact on the accuracy of the predicted annual energy consumption of buildings

  15. Comparison of lifts versus tape measure in determining leg length discrepancy.

    Science.gov (United States)

    Badii, Maziar; Wade, A Nicole; Collins, David R; Nicolaou, Savvakis; Kobza, B Jacek; Kopec, Jacek A

    2014-08-01

    To evaluate the validity (accuracy) and reliability of 2 commonly used clinical methods, 1 indirect (lifts) and 1 direct (tape measure), for assessment of leg length discrepancy (LLD) in comparison to radiograph. Twenty subjects suspected of having LLD participated in this study. Two clinical methods, 1 direct using a tape measure and 1 indirect using lifts, were standardized and carried out by 4 examiners. Difference in height of the femoral heads on standing pelvic radiograph was measured and served as the gold standard. The intraclass correlation coefficient assessing interobserver reliability was 0.737 for lifts and 0.477 for tape measure. The remainder of the analysis is based on the average of the measurements by the 4 examiners. Pearson correlation coefficients were 0.93 for the lifts and 0.75 for the tape measure method. Paired sample t tests showed difference in means of 2 mm (p = 0.051) for lifts and -5 mm (p = 0.007) for tape measure compared with radiograph. Sensitivity and specificity were 55% and 89% for lifts and 45% and 56% for tape measure, respectively, using > 5 mm as the definition for LLD. The wrong leg was identified as being shorter in 1 out of 20 subjects using lifts versus 7 out of 20 using tape measure. The indirect standing method of LLD measurement using lifts had superior validity, interobserver reliability, and specificity in comparison with radiograph over the direct supine method using tape measure. Both clinical methods underestimated LLD compared with radiograph.

  16. Reliability of length measurements collected by community nurses and health volunteers in rural growth monitoring and promotion services.

    Science.gov (United States)

    Laar, Matilda E; Marquis, Grace S; Lartey, Anna; Gray-Donald, Katherine

    2018-02-17

    Length measurements are important in growth, monitoring and promotion (GMP) for the surveillance of a child's weight-for-length and length-for-age. These two indices provide an indication of a child's risk of becoming wasted or stunted, and are more informative about a child's growth than the widely used weight-for-age index (underweight). Although the introduction of length measurements in GMP is recommended by the World Health Organization, concerns about the reliability of length measurements collected in rural outreach settings have been expressed by stakeholders. Our aim was to describe the reliability and challenges associated with community health personnel measuring length for rural outreach GMP activities. Two reliability studies (A and B), using 10 children less than 24 months each, were conducted in the GMP services of a rural district in Ghana. Fifteen nurses and 15 health volunteers (HV) with no prior experience in length measurements were trained. Intra- and inter-observer technical error of measurement (TEM), average bias from expert anthropometrist, and coefficient of reliability (R) of length measurements were assessed and compared across sessions. Observations and interviews were used to understand the ability and experiences of health personnel with measuring length at outreach GMP. Inter-observer TEM was larger than intra-observer TEM for both nurses and HV at both sessions and was unacceptably (compared to error standards) high in both groups at both time points. Average biases from expert's measurements were within acceptable limits, however, both groups tended to underestimate length measurements. The R for lengths collected by nurses (92.3%) was higher at session B compared to that of HV (87.5%). Length measurements taken by nurses and HV, and those taken by an experienced anthropometrist at GMP sessions were of moderate agreement (kappa = 0.53, p reliability of length measurements improved after two refresher trainings for nurses but

  17. Round-Trip System Available to Measure Path Length Variation in Korea VLBI System for Geodesy

    Science.gov (United States)

    Oh, Hongjong; Kondo, Tetsuro; Lee, Jinoo; Kim, Tuhwan; Kim, Myungho; Kim, Suchul; Park, Jinsik; Ju, Hyunhee

    2010-01-01

    The construction project of Korea Geodetic VLBI officially started in October 2008. The construction of all systems will be completed by the end of 2011. The project was named Korea VLBI system for Geodesy (KVG), and its main purpose is to maintain the Korea Geodetic Datum. In case of the KVG system, an observation room with an H-maser frequency standard is located in a building separated from the antenna by several tens of meters. Therefore KVG system will adopt a so-called round-trip system to transmit reference signals to the antenna with reduction of the effect of path length variations. KVG s round-trip system is designed not only to use either metal or optical fiber cables, but also to measure path length variations directly. We present this unique round trip system for KVG.

  18. A set-up to measure the optical attenuation length of scintillating fibres

    CERN Document Server

    Alfieri, C; Joram, C

    2015-01-01

    The optical attenuation length of a scintillating fibre characterizes the quality of light transport through the fibre. It relates directly to the quantity of detectable light at the readout end of the fibre. An optical bench has been constructed, which allows excitation of the fibre at various distances from the photodetector. Depending on the choice of the photodetector – Si-PIN photodiode or grating spectrometer – the attenuation length is measured as weighted average over the sensitivity of the photodetector or as a spectral distribution. A few examples illustrate its operation and performance. The set-up serves for fibre optimisation in the R&D phase and is expected to be used for systematic checks during the series production phase of the LHCb SciFi tracker project.

  19. Measurement of the $\\pi K$ atom lifetime and the $\\pi K$ scattering length

    CERN Document Server

    Adeva, B.; The PS212 collaboration; Allkofer, Y.; Amsler, C.; Anania, A.; Aogaki, S.; Benelli, A.; Brekhovskikh, V.; Cechak, T.; Chiba, M.; Chliapnikov, P.; Drijard, D.; Dudarev, A.; Dumitriu, D.; Federicova, P.; Fluerasu, D.; Gorin, A.; Gorchakov, O.; Gritsay, K.; Guaraldo, C.; Gugiu, M.; Hansroul, M.; Hons, Z.; Horikawa, S.; Iwashita, Y.; Karpukhin, V.; Kluson, J.; Kobayashi, M.; Kruglov, V.; Kruglova, L.; Kulikov, A.; Kulish, E.; Kuptsov, A.; Lamberto, A.; Lanaro, A.; Lednicky, R.; Marinas, C.; Martincik, J.; Nemenov, L.; Nikitin, M.; Okada, K.; Olchevskii, V.; Pentia, M.; Penzo, A.; Plo, M.; Prusa, P.; Rappazzo, G.; Romero Vidal, A.; Ryazantsev, A.; Rykalin, V.; Saborido, J.; Schacher, J.; Sidorov, A.; Smolik, J.; Takeutchi, F.; Tauscher, L.; Trojek, T.; Trusov, S.; Urban, T.; Vrba, T.; Yazkov, V.; Yoshimura, Y.; Zhabitsky, M.; Zrelov, P.

    2017-09-19

    After having announced the statistically significant observation (5.6~$\\sigma$) of the new exotic $\\pi K$ atom, the DIRAC experiment at the CERN proton synchrotron presents the measurement of the corresponding atom lifetime, based on the full $\\pi K$ data sample: $\\tau = (5.5^{+5.0}_{-2.8}) \\cdot 10^{-15}s$. By means of a precise relation ($<1\\%$) between atom lifetime and scattering length, the following value for the S-wave isospin-odd $\\pi K$ scattering length $a_0^{-}~=~\\frac{1}{3}(a_{1/2}-a_{3/2})$ has been derived: $\\left|a_0^-\\right| = (0.072^{+0.031}_{-0.020}) M_{\\pi}^{-1}$.

  20. Interferometer with Continuously Varying Path Length Measured in Wavelengths to the Reference Mirror

    Science.gov (United States)

    Ohara, Tetsuo (Inventor)

    2016-01-01

    An interferometer in which the path length of the reference beam, measured in wavelengths, is continuously changing in sinusoidal fashion and the interference signal created by combining the measurement beam and the reference beam is processed in real time to obtain the physical distance along the measurement beam between the measured surface and a spatial reference frame such as the beam splitter. The processing involves analyzing the Fourier series of the intensity signal at one or more optical detectors in real time and using the time-domain multi-frequency harmonic signals to extract the phase information independently at each pixel position of one or more optical detectors and converting the phase information to distance information.

  1. Measurement report on the LHC injection kicker ripple denition and maximum pulse length (MD 1268)

    CERN Document Server

    Bartmann, Wolfgang; Kotzian, Gerd; Stoel, Linda; Velotti, Francesco Maria; Vlachodimitropoulos, Vasileios; Wiesner, Christoph; CERN. Geneva. ATS Department

    2016-01-01

    The present LHC lling scheme uses a batch spacing which corresponds to the design report specication of the injection kicker rise time. A reduction of the batch spacing can be directly used to increase luminosity without detrimental eect on beam stability. Therefore, measurements were performed to understand if a tighter batch spacing would lead to increased injection oscillations of a the rst and last bunches of a bunch train and eventually also a growth of the transverse emittance. The results of theses measurement were used to dene the minimum possible batch spacing for an acceptable emittance growth. Another measurement was performed to test if a batch consisting of 320 bunches can be injected instead of the nominal 288 bunch trains. This bunch train is dierently produced in the LHC injectors and features an optimum between beam stability and luminosity gain. The pulse length of the injection kicker was measured to ensure the full batch can be injected at once.

  2. Comparison of Echo 7 field line length measurements to magnetospheric model predictions

    International Nuclear Information System (INIS)

    Nemzek, R.J.; Winckler, J.R.; Malcolm, P.R.

    1992-01-01

    The Echo 7 sounding rocket experiment injected electron beams on central tail field lines near L = 6.5. Numerous injections returned to the payload as conjugate echoes after mirroring in the southern hemisphere. The authors compare field line lengths calculated from measured conjugate echo bounce times and energies to predictions made by integrating electron trajectories through various magnetospheric models: the Olson-Pfitzer Quiet and Dynamic models and the Tsyganenko-Usmanov model. Although Kp at launch was 3-, quiet time magnetic models est fit the echo measurements. Geosynchronous satellite magnetometer measurements near the Echo 7 field lies during the flight were best modeled by the Olson-Pfitzer Dynamic Model and the Tsyganenko-Usmanov model for Kp = 3. The discrepancy between the models that best fit the Echo 7 data and those that fit the satellite data was most likely due to uncertainties in the small-scale configuration of the magnetospheric models. The field line length measured by the conjugate echoes showed some temporal variation in the magnetic field, also indicated by the satellite magnetometers. This demonstrates the utility an Echo-style experiment could have in substorm studies

  3. Measurement of cochlear length using the 'A' value for cochlea basal diameter: A feasibility study.

    Science.gov (United States)

    Deep, Nicholas L; Howard, Brittany E; Holbert, Sarah O; Hoxworth, Joseph M; Barrs, David M

    2017-07-01

    To determine whether the cochlea basal diameter (A value) measurement can be consistently and precisely obtained from high-resolution temporal bone imaging for use in cochlear length estimation. A feasibility study at a tertiary referral center was performed using the temporal bone CTs of 40 consecutive patients. The distance from the round window to the lateral wall was measured for each cochlea by two independent reviewers, a neuroradiologist and an otolaryngologist. The interrater reliability was calculated using the intraclass correlation coefficient (ICC) and the Bland-Altman plot. Forty patients (19 males, 21 females) for a total of 80 cochleae were included. Interrater reliability on the same ear had a high level of agreement by both the ICC and the Bland-Altman plot. ICCs were 0.90 (95% CI: 0.82, 0.94) for the left ear and 0.96 (95% CI: 0.92, 0.98) for the right ear. Bland-Altman plot confirmed interrater reliability with all 96% of measurements falling within the 95% limits of agreement. Measurement between the round window and lateral cochlear wall can be consistently and reliably obtained from high-resolution temporal bone CT scans. Thus, it is feasible to utilize this method to estimate the cochlear length of patients undergoing cochlear implantation.

  4. In Vivo Sarcomere Length Measurement in Whole Muscles during Passive Stretch and Twitch Contractions.

    Science.gov (United States)

    Young, Kevin W; Kuo, Bill P-P; O'Connor, Shawn M; Radic, Stojan; Lieber, Richard L

    2017-02-28

    Muscle force is dictated by micrometer-scale contractile machines called sarcomeres. Whole-muscle force drops from peak force production to zero with just a few micrometers of sarcomere length change. No current technology is able to capture adequate dynamic sarcomere data in vivo, and thus we lack fundamental data needed to understand human movement and movement disorders. Methods such as diffraction, endoscopy, and optical coherence tomography have been applied to muscle but are prohibitively invasive, sensitive to motion artifact, and/or imprecise. Here, we report dynamic sarcomere length measurement in vivo using a combination of our recently validated resonant reflection spectroscopy method combined with optical frequency domain interferometry. Using a 250-μm-wide fiber optic probe, we captured nanometer sarcomere length changes from thousands of sarcomeres on the sub-millisecond timescale during whole-muscle stretch and twitch contraction. We believe that this demonstrates the first large-scale sensing of sarcomere dynamics in vivo, which is a necessary first step to understand movement disorders and to create patient-specific surgical interventions and rehabilitation. Published by Elsevier Inc.

  5. Comparison between Conventional Blind Embryo Transfer and Embryo Transfer Based on Previously Measured Uterine Length

    Directory of Open Access Journals (Sweden)

    Nasrin Saharkhiz

    2014-11-01

    Full Text Available Background: Embryo transfer (ET is one of the most important steps in assisted reproductive technology (ART cycles and affected by many factors namely the depth of embryo deposition in uterus. In this study, the outcomes of intracytoplasmic sperm injection (ICSI cycles after blind embryo transfer and embryo transfer based on previously measured uterine length using vaginal ultrasound were compared. Materials and Methods: This prospective randomised clinical trial included one hundred and forty non-donor fresh embryo transfers during January 2010 to June 2011. In group I, ET was performed using conventional (blind method at 5-6cm from the external os, and in group II, ET was done at a depth of 1-1.5 cm from the uterine fundus based on previously measured uterine length using vaginal sonography. Appropriate statistical analysis was performed using Student’s t test and Chi-square or Fisher’s exact test. The software that we used was PASW statistics version 18. A p value <0.05 was considered statistically significant. Results: Chemical pregnancy rate was 28.7% in group I and 42.1% in group II, while the difference was not statistically significant (p=0.105. Clinical pregnancy, ongoing pregnancy and implantation rates for group I were 21.2%, 17.7%, and 12.8%, while for group II were 33.9%, 33.9%, and 22.1, respectively. In group I and group II, abortion rates were 34.7% and 0%, respectively, indicating a statistically significant difference (p<0.005. No ectopic pregnancy occurred in two groups. Conclusion: The use of uterine length measurement during treatment cycle in order to place embryos at depth of 1-1.5cm from fundus significantly increases clinical and ongoing pregnancy and implantation rates, while leads to a decrease in abortion rate (Registration Number: IRCT2014032512494N1.

  6. Effects of energy chirp on bunch length measurement in linear accelerator beams

    Science.gov (United States)

    Sabato, L.; Arpaia, P.; Giribono, A.; Liccardo, A.; Mostacci, A.; Palumbo, L.; Vaccarezza, C.; Variola, A.

    2017-08-01

    The effects of assumptions about bunch properties on the accuracy of the measurement method of the bunch length based on radio frequency deflectors (RFDs) in electron linear accelerators (LINACs) are investigated. In particular, when the electron bunch at the RFD has a non-negligible energy chirp (i.e. a correlation between the longitudinal positions and energies of the particle), the measurement is affected by a deterministic intrinsic error, which is directly related to the RFD phase offset. A case study on this effect in the electron LINAC of a gamma beam source at the Extreme Light Infrastructure-Nuclear Physics (ELI-NP) is reported. The relative error is estimated by using an electron generation and tracking (ELEGANT) code to define the reference measurements of the bunch length. The relative error is proved to increase linearly with the RFD phase offset. In particular, for an offset of {{7}\\circ} , corresponding to a vertical centroid offset at a screen of about 1 mm, the relative error is 4.5%.

  7. Diffusion length measurement using the scanning electron microscope. [for silicon solar cell

    Science.gov (United States)

    Weizer, V. G.

    1975-01-01

    The present work describes a measuring technique employing the scanning electron microscope in which values of the true bulk diffusion length are obtained. It is shown that surface recombination effects can be eliminated through application of highly doped surface field layers. The effects of high injection level and low-high junction current generation are investigated. Results obtained with this technique are compared to those obtained by a penetrating radiation (X-ray) method, and a close agreement is found. The SEM technique is limited to cells that contain a back surface field layer.

  8. Determination of {pi}{pi} scattering lengths from measurement of {pi}{sup +{pi}-} atom lifetime

    Energy Technology Data Exchange (ETDEWEB)

    Adeva, B. [Santiago de Compostela University (Spain); Afanasyev, L. [JINR Dubna (Russian Federation); Benayoun, M. [LPNHE des Universites Paris VI/VII, IN2P3-CNRS (France); Benelli, A. [Zurich University (Switzerland); Berka, Z. [Czech Technical University in Prague, Prague (Czech Republic); Brekhovskikh, V. [IHEP Protvino (Russian Federation); Caragheorgheopol, G. [IFIN-HH, National Institute for Physics and Nuclear Engineering, Bucharest (Romania); Cechak, T. [Czech Technical University in Prague, Prague (Czech Republic); Chiba, M. [Tokyo Metropolitan University (Japan); Chliapnikov, P.V. [IHEP Protvino (Russian Federation); Ciocarlan, C.; Constantinescu, S. [IFIN-HH, National Institute for Physics and Nuclear Engineering, Bucharest (Romania); Costantini, S. [Basel University (Switzerland); Curceanu, C. [IFIN-HH, National Institute for Physics and Nuclear Engineering, Bucharest (Romania); Doskarova, P. [Czech Technical University in Prague, Prague (Czech Republic); Dreossi, D. [INFN, Sezione di Trieste and Trieste University, Trieste (Italy); Drijard, D., E-mail: Daniel.Drijard@cern.ch [CERN, Geneva (Switzerland); Dudarev, A. [JINR Dubna (Russian Federation); Ferro-Luzzi, M. [CERN, Geneva (Switzerland); Fungueirino Pazos, J.L. [Santiago de Compostela University (Spain)

    2011-10-05

    The DIRAC experiment at CERN has achieved a sizeable production of {pi}{sup +{pi}-} atoms and has significantly improved the precision on its lifetime determination. From a sample of 21 227 atomic pairs, a 4% measurement of the S-wave {pi}{pi} scattering length difference |a{sub 0}-a{sub 2}|=(0.2533{sub -0.0078}{sup +0.0080}|{sub stat}{sup +0.0078}{sub -0.0073}|{sub syst})M{sub {pi}}{sup +-1} has been attained, providing an important test of Chiral Perturbation Theory.

  9. Improvement on a Michelson interferometer for bunch length measurement of a femtosecond accelerator

    International Nuclear Information System (INIS)

    Lin Xuling; Bei Hua; Zhang Jianbing; Dai Zhimin

    2009-01-01

    Based on the femtosecond accelerator facility at Shanghai Institute of Applied Physics (SINAP), a conventional far-infrared Michelson interferometer was built to measure the bunch length by means of optical autocorrelation. However, according to the preliminary experiment result, the resolution of interferometer is not good enough, because the mirror-driving mechanism makes the moving mirror tend to tilt or wobble as it retards. Considering of the allowable errors, we calculate the maximum allowable titling angle of the moving mirror, and discuss the alignment plan in this paper. (authors)

  10. An autocorrelation technique for measuring sub-picosecond bunch length using coherent transition radiation

    International Nuclear Information System (INIS)

    Barry, W.

    1991-01-01

    A new technique for determining sub-picosecond bunch length using infrared transition radiation and interferometry is proposed. The technique makes use of an infrared Michelson interferometer for measuring the autocorrelation of transition radiation emitted from a thin conducting foil placed in the beam path. The theory of coherent radiation from a charged particle beam passing through a thin conducting foil is presented. Subsequently, the analysis of this radiation through Michelson interferometry is shown to provide the autocorrelation of the longitudinal bunch profile. An example relevant to the CEBAF front end test is discussed. (author)

  11. Evaluation of a multimode fiber optic low coherence interferometer for path length resolved Doppler measurments of diffuse light

    NARCIS (Netherlands)

    Varghese, Babu; Rajan, Vinayakrishnan; van Leeuwen, Ton; Steenbergen, Wiendelt

    2007-01-01

    The performance of a graded index multimode fiber optic low coherence Mach-Zehnder interferometer with phase modulation is analyzed. Investigated aspects were its ability to measure path length distributions and to perform path length resolved Doppler measurements of multiple scattered photons in a

  12. Evaluation of a multimode fiber optic low coherence interferometer for path length resolved Doppler measurements of diffuse light

    NARCIS (Netherlands)

    Varghese, Babu; Rajan, Vinayakrishnan; van Leeuwen, Ton G.; Steenbergen, Wiendelt

    2007-01-01

    The performance of a graded index multimode fiber optic low coherence Mach-Zehnder interferometer with phase modulation is analyzed. Investigated aspects were its ability to measure path length distributions and to perform path length resolved Doppler measurements of multiple scattered photons in a

  13. [Mean length utterance (MLU) as a measure of language development of children with Down syndrome].

    Science.gov (United States)

    Marques, Suelen Fernanda; Limongi, Suelly Cecilia Olivan

    2011-01-01

    To characterize the mean length utterance in morphemes (MLU-m) and words (MLU-w) produced by children with Down syndrome (DS), and to verify the effectiveness of using EME-w as a measure of general language development of children with DS. Participants were 15 children with ages between 5 and 12 years, who were submitted to a free interaction situation. They were divided into three groups, according to chronological and mental age, as established by the results of the Primary Test of Nonverbal Intelligence. The first 100 utterances were analyzed considering: number of grammatical morphemes (GM) for articles, nouns and verbs (GM-1), and pronouns, prepositions and conjunctions (GM-2); mean length utterance for morphemes (MLU-m) and words (MLU-w). The between-groups comparison showed that the MLU averages were higher for older groups, and differences were found for all variables, except for GM-2. The same results were obtained in the within-group comparison, for all variables. There was a strong correlation between MLU-m and MLU-w. MLU-w can be used as an identification measure of general linguistic development. However, it is emphasized that the use of all MLU variables provides more efficacy in the characterization of linguistic development and the analysis of language impairments.

  14. Comparative evaluation of three methods to measure working length - Manual tactile sensation, digital radiograph, and multidetector computed tomography: Anin vitrostudy.

    Science.gov (United States)

    Dutta, Kaushik; Desai, Priti D; Das, Utapal Kumar; Sarkar, Soumayabrata

    2017-01-01

    Compare the measurement of working length with three different methods manual tactile sensation, digital radiography and Mutidetector computed tomography(MDCT). 40 human premolar extracted for orthodontic purpose were selected. Teeth were store in sodium chloride (0.9%) during the study. Access cavity was prepared and canal patency was seen with no 10 file in each tooth. Manually no 15 K file was inserted from access cavity until the tip was visible at the foramen, a silicon stopper was adjusted to the corresponding buccal cusp tip and the root canal length was measured. After that in each tooth with no-15 K file inserted from access cavity with stop at tip of buccal cusp until tip appear at foramen and x-ray was taken with digital radiograph (RVG,Satelac) and canal length was measured. After that all teeth are mounted in wax block,MDCT scan was done and in the scan images of teeth, root canal length is measured from buccal cusp tip to root end. After taking measurement of working length with all three methods and the data was stastically analyzed with One Way Analysis of variance (ANOVA) followed by Turkey's Test. ANOVA and turkeys test showed that there was no significant difference in the measurements by the three procedures (p>0.05). Working length measurement with MDCT scan and other two conventional methods does not show significant difference in measurement. Use of newer 3D imaging technique is useful in root canal treatment for measuring working length.

  15. Recent high-accuracy measurements of the 1S0 neutron-neutron scattering length

    International Nuclear Information System (INIS)

    Howell, C.R.; Chen, Q.; Gonzalez Trotter, D.E.; Salinas, F.; Crowell, A.S.; Roper, C.D.; Tornow, W.; Walter, R.L.; Carman, T.S.; Hussein, A.; Gibbs, W.R.; Gibson, B.F.; Morris, C.; Obst, A.; Sterbenz, S.; Whitton, M.; Mertens, G.; Moore, C.F.; Whiteley, C.R.; Pasyuk, E.; Slaus, I.; Tang, H.; Zhou, Z.; Gloeckle, W.; Witala, H.

    2000-01-01

    This paper reports two recent high-accuracy determinations of the 1 S 0 neutron-neutron scattering length, a nn . One was done at the Los Alamos National Laboratory using the π - d capture reaction to produce two neutrons with low relative momentum. The neutron-deuteron (nd) breakup reaction was used in other measurement, which was conducted at the Triangle Universities Nuclear Laboratory. The results from the two determinations were consistent with each other and with previous values obtained using the π - d capture reaction. The value obtained from the nd breakup measurements is a nn = -18.7 ± 0.1 (statistical) ± 0.6 (systematic) fm, and the value from the π - d capture experiment is a nn = -18.50 ± 0.05 ± 0.53 fm. The recommended value is a nn = -18.5 ± 0.3 fm. (author)

  16. Pelvic reference selection in patients with unilateral Crowe type IV DDH for measuring leg length inequality.

    Science.gov (United States)

    Zhang, Yanbo; Chang, Fei; Wang, Chenyu; Yang, Modi; Wang, Jincheng

    2015-01-01

    We identified the presence of deformities in the affected pelvis of unilateral Crowe type IV DDH patients, and if present, whether the teardrop and ischial lines were parallel with the sacral base line. We also verified whether the sacral base line provided a better pelvic landmark than the teardrop line for determining leg length inequality (LLI). After leveling the pelvis by using a block to lift the short leg, standard anterior-posterior full-length radiography was performed on 10 patients and 10 healthy volunteers as controls. The ratio of pelvic heights on each side of the pelvis, the angles formed by the sacral base line and the other 2 lines between 2 groups were measured. LLI were measured by sacral base line and teardrop line respectively. The ratio between the pelvic heights was lower in the patient group than in the control group (0.95 versus 0.99). The angles between the teardrop and ischial lines and the sacral base line in the patient group were both greater than in the control group (6.08° versus 0.92° and 7.13° versus 0.97°). LLI measured from the sacral base line was larger than from the teardrop line in the patient group (5.55 cm versus 4.36 cm). There was pelvic asymmetry and the sacral base line was not parallel with the other 2 lines in unilateral Crowe type IV DDH. The leveled sacral base line was perpendicular to the longitudinal axis of the body, and may be a better choice for accurate LLI measurement in this situation.

  17. Measurement of clavicular length and shortening after a midshaft clavicular fracture: Spatial digitization versus planar roentgen photogrammetry.

    Science.gov (United States)

    Stegeman, Sylvia A; de Witte, Pieter Bas; Boonstra, Sjoerd; de Groot, Jurriaan H; Nagels, Jochem; Krijnen, Pieta; Schipper, Inger B

    2016-08-01

    Clavicular shortening after fracture is deemed prognostic for clinical outcome and is therefore generally assessed on radiographs. It is used for clinical decision making regarding operative or non-operative treatment in the first 2weeks after trauma, although the reliability and accuracy of the measurements are unclear. This study aimed to assess the reliability of roentgen photogrammetry (2D) of clavicular length and shortening, and to compare these with 3D-spatial digitization measurements, obtained with an electromagnetic recording system (Flock of Birds). Thirty-two participants with a consolidated non-operatively treated two or multi-fragmented dislocated midshaft clavicular fracture were analysed. Two observers measured clavicular lengths and absolute and proportional clavicular shortening on radiographs taken before and after fracture consolidation. The clavicular lengths were also measured with spatial digitization. Inter-observer agreement on the radiographic measurements was assessed using the Intraclass Correlation Coefficient (ICC). Agreement between the radiographic and spatial digitization measurements was assessed using a Bland-Altman plot. The inter-observer agreement on clavicular length, and absolute and proportional shortening on trauma radiographs was almost perfect (ICC>0.90), but moderate for absolute shortening after consolidation (ICC=0.45). The Bland-Altman plot compared measurements of length on AP panorama radiographs with spatial digitization and showed that planar roentgen photogrammetry resulted in up to 37mm longer and 34mm shorter measurements than spatial digitization. Measurements of clavicular length on radiographs are highly reliable between observers, but may not reflect the actual length and shortening of the clavicle when compared to length measurements with spatial digitization. We recommend to use proportional shortening when measuring clavicular length or shortening on radiographs for clinical decision making. Copyright

  18. Foot length measurements of newborns of high and low risk pregnancies.

    Science.gov (United States)

    Salge, Ana Karina Marques; Rocha, Érika Lopes; Gaíva, Maria Aparecida Munhoz; Castral, Thaíla Correa; Guimarães, Janaína Valadares; Xavier, Raphaela Maioni

    2017-03-09

    Comparing foot length measurements of newborns in high and low risk pregnancies at a public hospital in Goiânia, GO, Brazil. A cross-sectional study carried out between April, 2013 and May, 2015, with a sample consisting of 180 newborns; 106 infants of women from high-risk pregnancies and 74 of women from low-risk pregnancies. Data were descriptively analyzed. Foot length measurement was performed using a stiff transparent plastic ruler, graduated in millimeters. The length of both feet was measured from the tip of the hallux (big toe) to the end of the heel. A statistically significant relationship was found between the foot length and newborn's weight, between the cephalic and thoracic perimeters in the high-risk group and between the cephalic perimeter in the control group. There is a need for creating cut-off points to identify newborns with intrauterine growth disorders using foot length. Comparar as medidas do comprimento hálux-calcâneo de recém-nascidos em gestações de alto e baixo risco em um hospital público de Goiânia, GO. Estudo transversal, realizado no período de abril de 2013 a maio de 2015, cuja amostra constituiu-se de 180 recém-nascidos, 106 filhos de mulheres com gestação de alto risco e 74 de mulheres com gestação de baixo risco. Os dados foram analisados descritivamente. A medida do comprimento hálux-calcâneo foi realizada utilizando-se de régua plástica transparente rígida, graduada em milímetros. Foram medidos ambos os pés, aferindo-se o comprimento da ponta do hálux até a extremidade do calcâneo. Foi encontrada relação estatisticamente significante entre o comprimento hálux-calcâneo e o peso do recém-nascido, entre os perímetros cefálico e torácico no grupo de alto risco e entre o perímetro cefálico no grupo controle. Existe necessidade da criação de pontos de corte para identificar recém-nascidos com desvios de crescimento intrauterino utilizando-se do comprimento hálux-calcâneo. Comparar las mediciones

  19. Retrieval of Effective Correlation Length and Snow Water Equivalent from Radar and Passive Microwave Measurements

    Directory of Open Access Journals (Sweden)

    Juha Lemmetyinen

    2018-01-01

    Full Text Available Current methods for retrieving SWE (snow water equivalent from space rely on passive microwave sensors. Observations are limited by poor spatial resolution, ambiguities related to separation of snow microstructural properties from the total snow mass, and signal saturation when snow is deep (~>80 cm. The use of SAR (Synthetic Aperture Radar at suitable frequencies has been suggested as a potential observation method to overcome the coarse resolution of passive microwave sensors. Nevertheless, suitable sensors operating from space are, up to now, unavailable. Active microwave retrievals suffer, however, from the same difficulties as the passive case in separating impacts of scattering efficiency from those of snow mass. In this study, we explore the potential of applying active (radar and passive (radiometer microwave observations in tandem, by using a dataset of co-incident tower-based active and passive microwave observations and detailed in situ data from a test site in Northern Finland. The dataset spans four winter seasons with daily coverage. In order to quantify the temporal variability of snow microstructure, we derive an effective correlation length for the snowpack (treated as a single layer, which matches the simulated microwave response of a semi-empirical radiative transfer model to observations. This effective parameter is derived from radiometer and radar observations at different frequencies and frequency combinations (10.2, 13.3 and 16.7 GHz for radar; 10.65, 18.7 and 37 GHz for radiometer. Under dry snow conditions, correlations are found between the effective correlation length retrieved from active and passive measurements. Consequently, the derived effective correlation length from passive microwave observations is applied to parameterize the retrieval of SWE using radar, improving retrieval skill compared to a case with no prior knowledge of snow-scattering efficiency. The same concept can be applied to future radar

  20. Use of a corrugated beam pipe as a passive deflector for bunch length measurements

    Science.gov (United States)

    Seok, Jimin; Chung, Moses; Kang, Heung-Sik; Min, Chang-Ki; Na, Donghyun

    2018-02-01

    We report the experimental demonstration of bunch length measurements using a corrugated metallic beam pipe as a passive deflector. The corrugated beam pipe has been adopted for reducing longitudinal chirping after the bunch compressors in several XFEL facilities worldwide. In the meantime, there have been attempts to measure the electron bunch's longitudinal current profile using the dipole wakefields generated in the corrugated pipe. Nevertheless, the bunch shape reconstructed from the nonlinearly deflected beam suffers from significant distortion, particularly near the head of the bunch. In this paper, we introduce an iterative process to improve the resolution of the bunch shape reconstruction. The astra and elegant simulations have been performed for pencil beam and cigar beam cases, in order to verify the effectiveness of the reconstruction process. To overcome the undesirable effects of transverse beam spreads, a measurement scheme involving both the corrugated beam pipe and the spectrometer magnet has been employed, both of which do not require a dedicated (and likely very expensive) rf system. A proof-of-principle experiment was carried out at Pohang Accelerator Laboratory (PAL) Injector Test Facility (ITF), and its results are discussed together with a comparison with the rf deflector measurement.

  1. Use of a corrugated beam pipe as a passive deflector for bunch length measurements

    Directory of Open Access Journals (Sweden)

    Jimin Seok

    2018-02-01

    Full Text Available We report the experimental demonstration of bunch length measurements using a corrugated metallic beam pipe as a passive deflector. The corrugated beam pipe has been adopted for reducing longitudinal chirping after the bunch compressors in several XFEL facilities worldwide. In the meantime, there have been attempts to measure the electron bunch’s longitudinal current profile using the dipole wakefields generated in the corrugated pipe. Nevertheless, the bunch shape reconstructed from the nonlinearly deflected beam suffers from significant distortion, particularly near the head of the bunch. In this paper, we introduce an iterative process to improve the resolution of the bunch shape reconstruction. The astra and elegant simulations have been performed for pencil beam and cigar beam cases, in order to verify the effectiveness of the reconstruction process. To overcome the undesirable effects of transverse beam spreads, a measurement scheme involving both the corrugated beam pipe and the spectrometer magnet has been employed, both of which do not require a dedicated (and likely very expensive rf system. A proof-of-principle experiment was carried out at Pohang Accelerator Laboratory (PAL Injector Test Facility (ITF, and its results are discussed together with a comparison with the rf deflector measurement.

  2. Axial Length Measurement Failure Rates with the IOLMaster and Lenstar LS 900 in Eyes with Cataract.

    Science.gov (United States)

    McAlinden, Colm; Wang, Qinmei; Pesudovs, Konrad; Yang, Xin; Bao, Fangjun; Yu, Ayong; Lin, Shishi; Feng, Yifan; Huang, Jinhai

    2015-01-01

    To evaluate axial length (AL) measurement failure rate with the IOLMaster (Carl Zeiss AG, Germany) and Lenstar LS 900 (Haag-Streit AG, Switzerland) in eyes with cataract. Two hundred and ninety-six eyes of 170 patients with cataract were enrolled. Cataract type and severity were graded using the Lens Opacities Classification System III (LOCS III) and AL measurements were attempted with IOLMaster (version 5.4) and Lenstar LS 900 (version 1.1). Chi-squared analysis was used to assess if the difference in AL measurement acquisition rate was statistically significant between the two devices. The association of the different cataract types and severity with the AL measurement acquisition rate was evaluated with logistic regression analysis. AL measurements were obtained in 184 eyes (62.16%) using the IOLMaster and 191 eyes (64.53%) using the Lenstar, which corresponds to a failure rate of 37.84% and 35.47% respectively. Chi-square analysis indicated no significant difference between the Lenstar and IOLMaster for AL measurement failure rate (x2 = 0.356, P = 0.550). Logistic regression analysis indicated no association between acquisition rates and cortical or nuclear cataracts with either device. There was a statistically significant association between acquisition rates and increasing severity of posterior subcapsular cataracts with the IOLMaster (β = -1.491, PLS 900 (β = -1.507, PLS 900 have similar AL measurement failure rates (35-38%) for Chinese public hospital cataract patients. Increasing severity of posterior subcapsular cataracts was problematic for both devices.

  3. A Study of an Information Retrieval Performance Measure: Expected Search Length as a Function of File Size and Organization.

    Science.gov (United States)

    Deutsch, Donald R.; Kraft, Donald H.

    A framework is developed to evaluate expected search length, an important measure of an information storage and retrieval system's performance, as a function of the size of the information file and its organization in terms of indexing search structure. Previous research pertaining to search length by W.S. Cooper and others is surveyed and…

  4. The validity of cone-beam computed tomography in measuring root canal length using a gold standard

    NARCIS (Netherlands)

    Liang, Y.H.; Jiang, L.; Chen, C.; Gao, X.J.; Wesselink, P.R.; Wu, M.K.; Shemesh, H.

    2013-01-01

    Introduction The distance between a coronal reference point and the major apical foramen is important for working length determination. The aim of this in vitro study was to determine the accuracy of root canal length measurements performed with cone-beam computed tomographic (CBCT) scans using a

  5. First $\\pi K$ atom lifetime and $\\pi K$ scattering length measurements

    CERN Document Server

    Adeva, B; Allkofer, Y; Amsler, C; Anania, A; Aogaki, S; Benelli, A; Brekhovskikh, V; Cechak, T; Chiba, M; Chliapnikov, P; Ciocarlan, C; Constantinescu, S; Doskarova, P; Drijard, D; Dudarev, A; Duma, M; Dumitriu, D; Fluerasu, D; Gorin, A; Gorchakov, O; Gritsay, K; Guaraldo, C; Gugiu, M; Hansroul, M; Hons, Z; Horikawa, S; Iwashita, Y; Karpukhin, V; Kluson, J; Kobayashi, M; Kruglov, V; Kruglova, L; Kulikov, A; Kulish, E; Kuptsov, A; Lamberto, A; Lanaro, A; Lednicky, R; Marinas, C; Martincik, J; Nemenov, L; Nikitin, M; Okada, K; Olchevskii, V; Pentia, M; Penzo, A; Plo, M; Ponta, T; Prusa, P; Rappazzo, G; Romero Vidal, A; Ryazantsev, A; Rykalin, V; Schacher, J; Sidorov, A; Smolik, J; Sugimoto, S; Takeutchi, F; Tauscher, L; Trojek, T; Trusov, S; Urban, T; Vrba, T; Yazkov, V; Yoshimura, Y; Zhabitsky, M; Zrelov, P

    2014-01-01

    The results of a search for hydrogen-like atoms consisting of $\\pi^{\\mp}K^{\\pm}$ mesons are presented. Evidence for $\\pi K$ atom production by 24 GeV/c protons from CERN PS interacting with a nickel target has been seen in terms of characteristic $\\pi K$ pairs from their breakup in the same target ($178 \\pm 49$) and from Coulomb final state interaction ($653 \\pm 42$). Using these results the analysis yields a first value for the $\\pi K$ atom lifetime of $\\tau=(2.5_{-1.8}^{+3.0})$ fs and a first model-independent measurement of the S-wave isospin-odd $\\pi K$ scattering length $\\left|a_0^-\\right|=\\frac{1}{3}\\left|a_{1/2}-a_{3/2}\\right|= \\left( 0.11_{-0.04}^{+0.09} \\right)M_{\\pi}^{-1}$ ($a_I$ for isospin $I$).

  6. Method for single-shot measurement of picosecond laser pulse-lengths without electronic time dispersion

    International Nuclear Information System (INIS)

    Kyrala, G.A.

    1987-01-01

    A two-source shear pattern recording is proposed as a method for single-shot measurement of the pulse shape from nearly monochromatic sources whose pulse lengths are shorter than their coherence times. The basis of this method relies on the assertion that if two identical electromagnetic pulses are recombined with a time delay greater than the sum of their pulse widths, the recordable spatial pattern has no fringes in it. At an arbitrary delay, translated into an actual spatial recording position, the recorded modulated intensity will sample the corresponding laser intensity at that delay time, but with a modulation due to the coherence function of the electromagnetic pulse. Two arrangements are proposed for recording the pattern. The principles, the design parameters, and the methodologies of these arrangements are presented. Resolutions of the configurations and their limitations are given as well

  7. Measurement of the neutron-neutron scattering length using the π-d capture reaction

    International Nuclear Information System (INIS)

    Chen, Q.; Howell, C. R.; Kiser, M. R.; Roper, C. D.; Salinas, F.; Setze, H. R.; Tornow, W.; Walter, R. L.; Carman, T. S.; Gibbs, W. R.; Gibson, B. F.; Morris, C.; Obst, A.; Sterbenz, S.; Whitton, M.; Hussein, A.; Mertens, G.; Moore, C. F.; Whiteley, C. R.; Pasyuk, E.

    2008-01-01

    We have determined a value for the 1 S 0 neutron-neutron scattering length (a nn ) from high-precision measurements of time-of-flight spectra of neutrons from the 2 H(π - ,n γ) n capture reaction. The measurements were done at the Los Alamos Meson Physics Facility by the E1286 Collaboration. The high spatial resolution of our γ-ray detector enabled us to make a detailed assessment of the systematic uncertainties in our techniques. The value obtained in the present work is a nn =-18.63±0.10 (statistical) ± 0.44 (systematic) ± 0.30 (theoretical) fm. This result is consistent with previous determinations of a nn from the π - d capture reaction. We found that the analysis of the data with calculations that use a relativistic phase-space factor gives a more negative value for a nn by 0.33 fm over the analysis done using a nonrelativistic phase-space factor. Combining the present result with the previous ones from π - d capture gives a nn =-18.63±0.27(expt)±0.30 fm (theory). For the first time the combined statistical and systematic experimental uncertainty in a nn is smaller than the theoretical uncertainty and comparable to the uncertainty in the proton-proton 1 S 0 scattering length (a pp ). This average value of a nn when corrected for the magnetic-moment interaction of the two neutrons becomes -18.9 ± 0.4 fm, which is 1.6 ± 0.5 fm different from the recommended value of a pp , thereby confirming charge symmetry breaking at the 1% confidence level

  8. Testing of focal plane arrays

    International Nuclear Information System (INIS)

    Merriam, J.D.

    1988-01-01

    Problems associated with the testing of focal plane arrays are briefly examined with reference to the instrumentation and measurement procedures. In particular, the approach and instrumentation used as the Naval Ocean Systems Center is presented. Most of the measurements are made with flooded illumination on the focal plane array. The array is treated as an ensemble of individual pixels, data being taken on each pixel and array averages and standard deviations computed for the entire array. Data maps are generated, showing the pixel data in the proper spatial position on the array and the array statistics

  9. Length, width and centroid distance as measures of teams tactical performance in youth football.

    Science.gov (United States)

    Folgado, Hugo; Lemmink, Koen A P M; Frencken, Wouter; Sampaio, Jaime

    2014-01-01

    Small-sided games are commonly used in training and teaching contexts of football. However, few studies have focused on the tactical implications of this type of drills. The aim of this study is to identify how tactical collective behaviour varies with age in different small-sided game formats. We investigated the in-game field position in three different age groups of youth football players [under-9 (n=10; age = 8.5 ± 0.53), under-11 (n=10; age = 10.4 ± 0.52) and under-13 (n=10; age = 12.7 ± 0.48)], participating in two different small-sided game conditions (GK + 3 × 3 + GK and GK + 4 × 4 + GK). A team variable was created based on the players' length per width ratio (lpwratio), and a match variable was calculated as the distance between the centroid of the two teams. Results show that team variable values were influenced by the age of the players, as younger teams tend to present a higher value of lpwratio in their dispersion on the pitch. The variability of this variable also showed a decrease for teams with older players, suggesting a more consistent application of the width (stretching and creating space) and concentration (compressing into a confined area) principles of play and reflecting a higher level of collective tactical behaviour. Match variable showed a larger centroid distance for the older age groups in comparison with the younger players in the GK + 3 × 3 + GK, while all age groups demonstrated similar large centroid distances in the GK + 4 × 4 + GK game format. These results suggest that length and width ratio and centroid distance are useful measures of tactical performance in small-sided games in youth football.

  10. Multiple measures of adiposity are associated with mean leukocyte telomere length in the Northern Finland birth cohort 1966

    OpenAIRE

    Buxton, Jessica L.; Das, Shikta; Rodriguez, Alina; Kaakinen, Marika; Couto Alves, Alexessander; Sebert, Sylvain; Millwood, Iona Y.; Laitinen, Jaana; O’Reilly, Paul F.; Jarvelin, Marjo-Riitta; Blakemore, Alexandra I. F.

    2014-01-01

    Studies of leukocyte telomere length (LTL) and adiposity have produced conflicting results, and the relationship between body mass index (BMI) and telomere length throughout life remains unclear. We therefore tested association of adult LTL measured in 5,598 participants with: i) childhood growth measures (BMI and age at adiposity rebound (AR)); ii) change in BMI from childhood to adulthood and iii) adult BMI, waist-to-hip ratio (WHR), body adiposity index (BAI). Childhood BMI at AR was posit...

  11. Cell length measurements in longitudinal smooth muscle strips of the pig urinary bladder

    NARCIS (Netherlands)

    E. van Asselt (Els); R. Schot (Rachel); R. van Mastrigt (Ron)

    1993-01-01

    textabstractIn this study the length of smooth muscle cells in muscle bundles of pig urinary bladder wall was determined after dissection in Tyrode buffers with different calcium concentrations ([Ca2+]). Previous studies have shown that the length of isolated smooth muscle cells decreases with an

  12. How Does Definition of Minimum Break Length Affect Objective Measures of Sitting Outcomes Among Office Workers?

    DEFF Research Database (Denmark)

    Kloster, Stine; Danquah, Ida Høgstedt; Holtermann, Andreas

    2017-01-01

    described how the definition of minimum break duration affects sitting outcomes. Therefore, the aim was to address how definitions of break length affect total sitting time, number of sit-to-stand transitions, prolonged sitting periods and time accumulated in prolonged sitting periods among office workers......-to-stand transitions decreased, and number of prolonged sitting periods and total time accumulated in prolonged sitting periods increased, with increasing minimum break length. Total sitting time was not influenced by varying break length. CONCLUSIONS: The definition of minimum break length influenced the sitting...... outcomes with the exception of total sitting time. A standard definition of break length is needed for comparison and interpretation of studies in the evolving research field of sedentary behaviour....

  13. Stride length determination during overground running using a single foot-mounted inertial measurement unit.

    Science.gov (United States)

    Brahms, C Markus; Zhao, Yang; Gerhard, David; Barden, John M

    2018-02-10

    From a research perspective, detailed knowledge about stride length (SL) is important for coaches, clinicians and researchers because together with stride rate it determines the speed of locomotion. Moreover, individual SL vectors represent the integrated output of different biomechanical determinants and as such provide valuable insight into the control of running gait. In recent years, several studies have tried to estimate SL using body-mounted inertial measurement units (IMUs) and have reported promising results. However, many studies have used systems based on multiple sensors or have only focused on estimating SL for walking. Here we test the concurrent validity of a single foot-mounted, 9-degree of freedom IMU to estimate SL for running. We employed a running-specific, Kalman filter based zero-velocity update (ZUPT) algorithm to calculate individual SL vectors with the IMU and compared the results to SLs that were simultaneously recorded by a 6-camera 3D motion capture system. The results showed that the analytical procedures were able to successfully identify all strides that were recorded by the camera system and that excellent levels of absolute agreement (ICC(3,1) = 0.955) existed between the two methods. The findings demonstrate that individual SL vectors can be accurately estimated with a single foot-mounted IMU when running in a controlled laboratory setting. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Model of vortex dynamics in superconducting films in two-coil measurements of the coherence length

    Science.gov (United States)

    Lemberger, Thomas; Loh, Yen Lee

    In two-coil measurements on superconducting films, a magnetic field from a small coil is applied to the center of the film. When the amplitude of the ac field is increased, the film undergoes a transition from the ``Meissner'' state to a state with vortices and antivortices. Ultimately, the vortex density matches the applied magnetic field and field screening is negligible. Experimentally, the field at the transition is related to the superconducting coherence length, although a full theory of the relationship is lacking. We show that the mutual inductance between drive and pickup coils, on opposite sides of the film, as a function of ac field amplitude is well-described by a phenomenological model in which vortices and antivortices appear together in the film at the radius where the induced supercurrent is strongest, and then they move through a landscape of moderately strong vortex pinning sites. Work at OSU supported by DOE-Basic Energy Sciences through Grant No. FG02-08ER46533.

  15. Is sonographically measured cervical length at 37 weeks of gestation associated with intrapartum cesarean section? A prospective cohort study.

    Science.gov (United States)

    de Vries, Bradley; Narayan, Rajit; McGeechan, Kevin; Santiagu, Stanley; Vairavan, Ramesh; Burke, Minke; Phipps, Hala; Hyett, Jon

    2018-02-16

    Cesarean section rates continue to increase globally. Prediction of intrapartum cesarean section could lead to preventive measures. Our aim was to assess the association between sonographically measured cervical length at 37 weeks of gestation and cesarean section among women planning a vaginal birth. The population was women with a low-risk pregnancy or with gestational diabetes. This was a prospective cohort study conducted in a tertiary referral hospital in Sydney, Australia. In all, 212 women with a low-risk pregnancy or with gestational diabetes were recruited including 158 nulliparous and 54 parous women. Maternal demographic, clinical and ultrasound characteristics were collected at 37 weeks of gestation. Semi-Bayesian logistic regression and Markov chain Monte Carlo simulation were used to assess the relationship between cervical length and cesarean section in labor. Rates of cesarean section were 5% (2/55) for cervical length ≤20 mm, 17% (17/101) for cervical length 20-32 mm, and 27% (13/56) for cervical length >32 mm. These rates were 4, 22 and 33%, respectively, in nulliparous women. In the semi-Bayesian analysis, the odds ratio for cesarean section was 6.2 (95% confidence interval 2.2-43) for cervical length 20-32 mm and 10 (95% confidence interval 4.8-74) for cervical length >32 mm compared with the lowest quartile of cervical length, after adjusting for maternal age, parity, height, prepregnancy body mass index, gestational diabetes, induction of labor, neonatal sex and birthweight centile. Cervical length at 37 weeks of gestation is associated with intrapartum cesarean section. © 2018 Nordic Federation of Societies of Obstetrics and Gynecology.

  16. Triage by cervical length sonographic measurements for targeted therapy in threatened preterm labor: A double blind randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Homeira Vafaei

    2017-11-01

    Full Text Available Background: Preterm labor and birth are associated with several neonatal complications including respiratory distress syndrome and intraventricular hemorrhage. Differentiating true and false labor pain is a dilemma to obstetricians. Objective: To elucidate the role of cervical length measurement in prediction of birth in pregnant women with threatened preterm labor. Materials and Methods: In this double blind randomized clinical trial, 120 women with gestational age <34 wk who presented painful uterine contractions randomly assigned to undergo measurement of cervical length. Patients were registered in the hospital and a unit number was given. Based on the unit numbers, patients were randomly assigned to two groups using a computerized random digit generator. All participants were managed accordingly (n=65 or to receive tocolysis as planned (n=55. Tocolysis was prescribed when cervical length was <15 mm while those with cervical length ≥15 mm were managed expectantly. Delivery within 7 days of the presentation was the primary outcome. Results: This RCT showed in case group, 78.9% of patient with cervical length <15 mm were delivered within 7 days and only 21.1% of them maintained their pregnancy. Of those with cervical length ≥15 mm, only 15.2% were delivered within the study period and the rest (84.8% maintained their pregnancy (p<0.001. Conclusion: “Our results indicate that in women who presented preterm labor symptoms, cervical length measurement will result in decreased unnecessary tocolytic treatment. Women with cervical length ≥15mm should not receive tocolysis, however, withholding corticosteroid therapy in these patients needs further evidence.

  17. Length distribution of single-walled carbon nanotubes in aqueous suspension measured by electrospray differential mobility analysis.

    Science.gov (United States)

    Pease, Leonard F; Tsai, De-Hao; Fagan, Jeffery A; Bauer, Barry J; Zangmeister, Rebecca A; Tarlov, Michael J; Zachariah, Michael R

    2009-12-01

    The first characterization of the length distribution of single-walled carbon nanotubes (SWCNT) dispersed in a liquid by electrospray differential mobility analysis (ES-DMA) is presented. Although an understanding of geometric properties of SWCNTs, including length, diameter, aspect ratio, and chirality, is essential for commercial applications, rapid characterization of nanotube length distributions remains challenging. Here the use of ES-DMA to obtain length distributions of DNA-wrapped SWCNTs dispersed in aqueous solutions is demonstrated. Lengths measured by ES-DMA compare favorably with those obtained from multiangle light scattering, dynamic light scattering, field flow fractionation with UV/vis detection, and atomic force microscopy, validating ES-DMA as a technique to measure SWCNTs of <250 nm in length. The nanotubes are previously purified and dispersed by wrapping with oligomeric DNA in aqueous solution and centrifuging to remove bundles and amorphous carbon. These dispersions are particularly attractive due to their amenability to bulk processing, ease of storage, high concentration, compatibility with biological and high-throughput manufacturing environments, and for their potential applications ranging from electronics and hydrogen-storage vessels to anticancer agents.

  18. Accuracy of measurement by laser diffraction method of length of contracting muscle sarcomeres

    Energy Technology Data Exchange (ETDEWEB)

    Klimov, A.A.; Andreyev, O.A.

    The method of laser beam diffraction was used on striate muscle fibers to study changes in sarcomere length during contraction, as determined by the angular distance between (+1)-(left) and (-1)-(right) diffraction maximums. The course of force development was recorded simultaneously. The absolute margin of error in determining the mean length of sarcomeres did not exceed 0.05 ..mu..m in the range of 1.8 to 2.8 ..mu..m lengths, and 0.1 ..mu..m in the range of 2.8 to 3.3. Changes in mean length of sarcomeres were recorded with accuracy to 0.003 ..mu..m with concurrent monitoring of positions (+1) and (-1) maximums. It was demonstrated that during fiber contraction there is shifting not only of (+1) and (-1) maximums, but (0) maximum also, which is attributable to the effects of light refraction with change in shape of illuminated segment of fiber. This change can be caused by redistribution of sarcomere lengths along the axis of the fiber during contraction and, accordingly, local changes in fiber diameter.

  19. Measured tube technique for ensuring the correct length of slippery artificial chordae in mitral valvuloplasty.

    Science.gov (United States)

    Matsui, Yoshiro; Kubota, Suguru; Sugiki, Hiroshi; Wakasa, Satoshi; Ooka, Tomonori; Tachibana, Tsuyoshi; Sasaki, Shigeyuki

    2011-09-01

    Mitral valvuloplasty using Gore-Tex (W.L. Gore & Associates, Inc, Flagstaff, AZ) as artificial chordae is often associated with difficulties in determining the length of the artificial chordae, as well as preventing knot slippage, especially for patients with broad anterior leaflet prolapse. We describe a simple technique that enables surgeons to easily determine the correct length of the artificial chordae and tie slippery knots without using a specific device. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Vertebral height as the measure of lesion length in carcinoma of the ...

    African Journals Online (AJOL)

    With the modified tech- nique it was possible to decrease treat- ment length and the number of nor- mal oesophageal mucosa in the treat- ment volume, thereby reducing the chance of treatment-related complica- tions such as strictures and ulceration. Introduction. The majority of patients with car- cinoma of the oesophagus ...

  1. Improved theory of time domain reflectometry with variable coaxial cable length for electrical conductivity measurements

    Science.gov (United States)

    Although empirical models have been developed previously, a mechanistic model is needed for estimating electrical conductivity (EC) using time domain reflectometry (TDR) with variable lengths of coaxial cable. The goals of this study are to: (1) derive a mechanistic model based on multisection tra...

  2. Importance of epoch length and registration time on accelerometer measurements in younger children

    DEFF Research Database (Denmark)

    Dencker, M; Svensson, J; El-Naaman, B

    2012-01-01

    The aim of this study was to investigate the effect of epoch length on accumulation of minutes of physical activity per day over a spectrum of intensities, and the effect that selection of number of hours of acceptable registration required per day had on number of days that were considered accep...

  3. Accuracy and head positioning effects on measurements of anterior tooth length using 3-dimensional and conventional dental panoramic radiography.

    Science.gov (United States)

    Kitai, Noriyuki; Murabayashi, Manabu; Sugimoto, Hiroshi; Fujiwara, Atsushi; Tome, Wakako; Katsumata, Akitoshi

    2017-03-01

    The purposes of this study were to examine the accuracy and the head positioning effects on measurements of anterior tooth length using 3-dimensional (3D) and conventional dental panoramic radiography and to investigate whether 3D panoramic radiography is suitable for the evaluation of anterior tooth length. A simulated human head was radiographed at 4, 8, and 12 mm displaced positions, and at 5°, 10°, and 15° tilted positions from the standard head position using 3D and conventional panoramic radiography, and also using cone-beam computed tomography. Anterior tooth lengths were measured on the panoramic and cone-beam computed tomography images. The values for the standard head position in the panoramic radiographs were defined as the standard values. Measurement error was defined as the standard value minus the cone-beam computed tomography value on each panoramic radiograph. The head position ratio of the measurement value to the standard value at each head position was calculated. Measurement errors for the 3D panoramic radiographs were significantly smaller than those for the conventional panoramic radiographs. In the 3D panoramic radiographs, the head position ratios at the 4, 8, and 12 mm displaced positions and at the 5° tilted position were within ±5% of the standard value. Three-dimensional panoramic radiography is suitable for the quantitative evaluation of anterior tooth length with high accuracy. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  4. Influence of Landscape Coverage on Measuring Spatial and Length Properties of Rock Fracture Networks: Insights from Numerical Simulation

    Science.gov (United States)

    Cao, Wenzhuo; Lei, Qinghua

    2018-01-01

    Natural fractures are ubiquitous in the Earth's crust and often deeply buried in the subsurface. Due to the difficulty in accessing to their three-dimensional structures, the study of fracture network geometry is usually achieved by sampling two-dimensional (2D) exposures at the Earth's surface through outcrop mapping or aerial photograph techniques. However, the measurement results can be considerably affected by the coverage of forests and other plant species over the exposed fracture patterns. We quantitatively study such effects using numerical simulation. We consider the scenario of nominally isotropic natural fracture systems and represent them using 2D discrete fracture network models governed by fractal and length scaling parameters. The groundcover is modelled as random patches superimposing onto the 2D fracture patterns. The effects of localisation and total coverage of landscape patches are further investigated. The fractal dimension and length exponent of the covered fracture networks are measured and compared with those of the original non-covered patterns. The results show that the measured length exponent increases with the reduced localisation and increased coverage of landscape patches, which is more evident for networks dominated by very large fractures (i.e. small underlying length exponent). However, the landscape coverage seems to have a minor impact on the fractal dimension measurement. The research findings of this paper have important implications for field survey and statistical analysis of geological systems.

  5. Measurements of 3D slip velocities and plasma column lengths of a gliding arc discharge

    DEFF Research Database (Denmark)

    Zhu, Jiajian; Gao, Jinlong; Ehn, Andreas

    2015-01-01

    A non-thermal gliding arc discharge was generated at atmospheric pressure in an air flow. The dynamics of the plasma column and tracer particles were recorded using two synchronized high-speed cameras. Whereas the data analysis for such systems has previously been performed in 2D (analyzing...... the single camera image), we provide here a 3D data analysis that includes 3D reconstructions of the plasma column and 3D particle tracking velocimetry based on discrete tomography methods. The 3D analysis, in particular, the determination of the 3D slip velocity between the plasma column and the gas flow......, gives more realistic insight into the convection cooling process. Additionally, with the determination of the 3D slip velocity and the 3D length of the plasma column, we give more accurate estimates for the drag force, the electric field strength, the power per unit length, and the radius...

  6. Measurements of 3D slip velocities and plasma column lengths of a gliding arc discharge

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Jiajian; Gao, Jinlong; Ehn, Andreas; Aldén, Marcus; Li, Zhongshan, E-mail: zhongshan.li@forbrf.lth.se, E-mail: alpers@ma.tum.de [Division of Combustion Physics, Lund University, P.O. Box 118, S-221 00 Lund (Sweden); Moseev, Dmitry [Max-Planck-Institut für Plasmaphysik, D-85748 Garching bei München (Germany); FOM Institute DIFFER, 3430 BE Nieuwegein (Netherlands); Kusano, Yukihiro [Department of Wind Energy, Section for Composites and Materials Mechanics, Technical University of Denmark, Risø Campus, Frederiksborgvej 399, DK-4000 Roskilde (Denmark); Salewski, Mirko [Department of Physics, Section for Plasma Physics and Fusion Energy, Technical University of Denmark, DK-2800 Kongens Lyngby (Denmark); Alpers, Andreas, E-mail: zhongshan.li@forbrf.lth.se, E-mail: alpers@ma.tum.de; Gritzmann, Peter; Schwenk, Martin [Zentrum Mathematik, Technische Universität München, D-85747 Garching bei München (Germany)

    2015-01-26

    A non-thermal gliding arc discharge was generated at atmospheric pressure in an air flow. The dynamics of the plasma column and tracer particles were recorded using two synchronized high-speed cameras. Whereas the data analysis for such systems has previously been performed in 2D (analyzing the single camera image), we provide here a 3D data analysis that includes 3D reconstructions of the plasma column and 3D particle tracking velocimetry based on discrete tomography methods. The 3D analysis, in particular, the determination of the 3D slip velocity between the plasma column and the gas flow, gives more realistic insight into the convection cooling process. Additionally, with the determination of the 3D slip velocity and the 3D length of the plasma column, we give more accurate estimates for the drag force, the electric field strength, the power per unit length, and the radius of the conducting zone of the plasma column.

  7. ABSOLUTE BUNCH LENGTH MEASUREMENTS AT THE ALS BY INCOHERENTSYNCHROTRON RADIATION FLUCTUATION ANALYSIS

    Energy Technology Data Exchange (ETDEWEB)

    Sannibale, Fernando; Zolotorev, Max S.; Filippetto, Daniele; Stupakov, Gennady V.

    2007-06-22

    By analysing the pulse to pulse intensity fluctuations ofthe radiation emitted by a charge particle in the incoherent part of thespectrum, it is possible to extract information about the spatialdistribution of the beam. At the Advanced Light Source (ALS) of theLawrence Berkeley National Laboratory, we have developed and tested asimple scheme based on this principle that allows for the absolutemeasurement of the bunch length. A description of the method and theexperimental results are presented.

  8. In Vivo Sarcomere Length Measurement in Whole Muscles during Passive Stretch and Twitch Contractions

    OpenAIRE

    Young, Kevin W.; Kuo, Bill P.-P.; O’Connor, Shawn M.; Radic, Stojan; Lieber, Richard L.

    2017-01-01

    Muscle force is dictated by micrometer-scale contractile machines called sarcomeres. Whole-muscle force drops from peak force production to zero with just a few micrometers of sarcomere length change. No current technology is able to capture adequate dynamic sarcomere data in vivo, and thus we lack fundamental data needed to understand human movement and movement disorders. Methods such as diffraction, endoscopy, and optical coherence tomography have been applied to muscle but are prohibitive...

  9. Simultaneous Water Vapor and Dry Air Optical Path Length Measurements and Compensation with the Large Binocular Telescope Interferometer

    Science.gov (United States)

    Defrere, D.; Hinz, P.; Downey, E.; Boehm, M.; Danchi, W. C.; Durney, O.; Ertel, S.; Hill, J. M.; Hoffmann, W. F.; Mennesson, B.; hide

    2016-01-01

    The Large Binocular Telescope Interferometer uses a near-infrared camera to measure the optical path length variations between the two AO-corrected apertures and provide high-angular resolution observations for all its science channels (1.5-13 microns). There is however a wavelength dependent component to the atmospheric turbulence, which can introduce optical path length errors when observing at a wavelength different from that of the fringe sensing camera. Water vapor in particular is highly dispersive and its effect must be taken into account for high-precision infrared interferometric observations as described previously for VLTI/MIDI or the Keck Interferometer Nuller. In this paper, we describe the new sensing approach that has been developed at the LBT to measure and monitor the optical path length fluctuations due to dry air and water vapor separately. After reviewing the current performance of the system for dry air seeing compensation, we present simultaneous H-, K-, and N-band observations that illustrate the feasibility of our feed forward approach to stabilize the path length fluctuations seen by the LBTI nuller uses a near-infrared camera to measure the optical path length variations between the two AO-corrected apertures and provide high-angular resolution observations for all its science channels (1.5-13 microns). There is however a wavelength dependent component to the atmospheric turbulence, which can introduce optical path length errors when observing at a wavelength different from that of the fringe sensing camera. Water vapor in particular is highly dispersive and its effect must be taken into account for high-precision infrared interferometric observations as described previously for VLTI MIDI or the Keck Interferometer Nuller. In this paper, we describe the new sensing approach that has been developed at the LBT to measure and monitor the optical path length fluctuations due to dry air and water vapor separately. After reviewing the current

  10. [Vasa praevia diagnosis during transvaginal measurement of cervical length as preventing preterm delivery in the second quarter].

    Science.gov (United States)

    Belmonte-Andújar, L I; Fuentes-Rozalén, A M; Soler-Garcia, R M

    2016-03-01

    Vasa praevia is a rare pregnancy complication with a high fetal mortality when not diagnosed in the prenatal period. two cases of vasa praevia diagnosed during the second trimester ultrasound cervical measurement. We propose carry out further investigation about cost effectiveness of double vaginal screening (cervical length measurement and vasa praevia) during the second trimester morphology ultrasound. This implementation could allow to reduce the high mortality associated to this obstetric complication.

  11. Application of a Low-Energy Electron Beam as a Tool for ultrashort bunch length measurement in circular machines

    CERN Document Server

    Nikiforov, D A; Malyutin, D; Matveenko, A; Rusinov, K; Starostenko, A A

    2017-01-01

    A new diagnostic device designed for non-destructive ultrashort bunch length measurement is described. The operating principle of the device and the measuring technique are described. The possible scheme of arrangement of the device elements are described. The results of simulations of EBP application for different beams under investigation are presented. The quality requirements of the low energy testing beam are considered and resolving detector ability is determined.

  12. Correlation of Leukocyte Telomere Length Measurement Methods in Patients with Dyskeratosis Congenita and in Their Unaffected Relatives

    OpenAIRE

    Khincha, Payal P.; Dagnall, Casey L.; Hicks, Belynda; Jones, Kristine; Aviv, Abraham; Kimura, Masayuki; Katki, Hormuzd; Aubert, Geraldine; Giri, Neelam; Alter, Blanche P.; Savage, Sharon A.; Gadalla, Shahinaz M.

    2017-01-01

    Several methods have been employed to measure telomere length (TL) in human studies. It has been difficult to directly compare the results from these studies because of differences in the laboratory techniques and output parameters. We compared TL measurements (TLMs) by the three most commonly used methods, quantitative polymerase chain reaction (qPCR), flow cytometry with fluorescence in situ hybridization (flow FISH) and Southern blot, in a cohort of patients with the telomere biology disor...

  13. Length and volume of morphologically normal kidneys in Korean Children: Ultrasound measurement and estimation using body size

    International Nuclear Information System (INIS)

    Kim, Jun Hwee; Kim, Myung Joon; Lim, Sok Hwan; Lee, Mi Jung; Kim, Ji Eun

    2013-01-01

    To evaluate the relationship between anthropometric measurements and renal length and volume measured with ultrasound in Korean children who have morphologically normal kidneys, and to create simple equations to estimate the renal sizes using the anthropometric measurements. We examined 794 Korean children under 18 years of age including a total of 394 boys and 400 girls without renal problems. The maximum renal length (L) (cm), orthogonal anterior-posterior diameter (D) (cm) and width (W) (cm) of each kidney were measured on ultrasound. Kidney volume was calculated as 0.523 x L x D x W (cm 3 ). Anthropometric indices including height (cm), weight (kg) and body mass index (m 2 /kg) were collected through a medical record review. We used linear regression analysis to create simple equations to estimate the renal length and the volume with those anthropometric indices that were mostly correlated with the US-measured renal sizes. Renal length showed the strongest significant correlation with patient height (R2, 0.874 and 0.875 for the right and left kidneys, respectively, p < 0.001). Renal volume showed the strongest significant correlation with patient weight (R2, 0.842 and 0.854 for the right and left kidneys, respectively, p < 0.001). The following equations were developed to describe these relationships with an estimated 95% range of renal length and volume (R2, 0.826-0.884, p < 0.001): renal length = 2.383 + 0.045 x Height (± 1.135) and = 2.374 + 0.047 x Height (± 1.173) for the right and left kidneys, respectively; and renal volume 7.941 + 1.246 x Weight (± 15.920) and = 7.303 + 1.532 x Weight (± 18.704) for the right and left kidneys, respectively. Scatter plots between height and renal length and between weight and renal volume have been established from Korean children and simple equations between them have been developed for use in clinical practice.

  14. Coupling of relative intensity noise and pathlength noise to the length measurement in the optical metrology system of LISA Pathfinder

    Science.gov (United States)

    Wittchen, Andreas; the LPF Collaboration

    2017-05-01

    LISA Pathfinder is a technology demonstration mission for the space-based gravitational wave observatory, LISA. It demonstrated that the performance requirements for the interferometric measurement of two test masses in free fall can be met. An important part of the data analysis is to identify the limiting noise sources. [1] This measurement is performed with heterodyne interferometry. The performance of this optical metrology system (OMS) at high frequencies is limited by sensing noise. One such noise source is Relative Intensity Noise (RIN). RIN is a property of the laser, and the photodiode current generated by the interferometer signal contains frequency dependant RIN. From this electric signal the phasemeter calculates the phase change and laser power, and the coupling of RIN into the measurement signal depends on the noise frequency. RIN at DC, at the heterodyne frequency and at two times the heterodyne frequency couples into the phase. Another important noise at high frequencies is path length noise. To reduce the impact this noise is suppressed with a control loop. Path length noise not suppressed will couple directly into the length measurement. The subtraction techniques of both noise sources depend on the phase difference between the reference signal and the measurement signal, and thus on the test mass position. During normal operations we position the test mass at the interferometric zero, which is optimal for noise subtraction purposes. This paper will show results from an in-flight experiment where the test mass position was changed to make the position dependant noise visible.

  15. A volumetric approach to path-length measurements is essential when treating radiotherapy with modulated beams

    Energy Technology Data Exchange (ETDEWEB)

    Forde, Elizabeth, E-mail: eforde@tcd.ie [Discipline of Radiation Therapy, School of Medicine, Trinity College Dublin, Dublin (Ireland); Booth, Jeremy [Northern Sydney Cancer Centre, Royal North Shore Hospital, New South Wales (Australia); Leech, Michelle [Discipline of Radiation Therapy, School of Medicine, Trinity College Dublin, Dublin (Ireland)

    2014-07-01

    The established dosimetric benefits of intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy have lead to their increased use in prostate radiotherapy. Complimenting these techniques, volumetric image guidance has supported increased positional accuracy. In addition, 3-dimensional image guidance has also allowed for assessment of potential dosimetric variation that can be attributed to a deformation of either internal or external structures, such as rectal distension or body contour. Compounding these issues is the variation of tissue density through which the new field position passes and also the variation of dose across a modulated beam. Despite the growing level of interest in this area, there are only a limited number of articles that examine the effect of a variation in beam path length, particularly across a modulated field. IMRT and volumetric-modulated radiation therapy (VMAT) fields are dynamic in nature, and the dose gradient within these fields is variable. Assessment of variation of path length away from the beam's central axis and across the entire field is vital where there is considerable variation of dose within the field, such as IMRT and VMAT. In these cases, reliance on the traditional central axis to focus skin distances is no longer appropriate. This article discusses these more subtle challenges that may have a significant clinical effect if left unrecognized and undervalued.

  16. Correlation of intra-articular osseous measurements with posterior cruciate ligament length on MRI scans.

    LENUS (Irish Health Repository)

    Orakzai, S H

    2010-01-01

    Six patients with a clinical diagnosis of chronic posterior cruciate ligament (PCL) rupture, based on a positive posterior drawer test, had a normal appearance of the PCL on an MRI scan. It is postulated that the PCL had been ruptured but healed in a lengthened state. 12 volunteers with no history of knee trauma underwent an MRI scan of the knee. In this control group (n = 12), there was a close correlation between the lateral femoral condylar width in the sagittal plane and the PCL length, with a ratio of 2:1 (95% confidence interval (CI) = 1.817-2.095). In the clinically abnormal group (n = 6), the ratio was 1.49:1 (95% CI = 1.206-1.782) (p< 0.0005). In conclusion, the ratio of the lateral femoral condylar width in the sagittal plane to the PCL length is a useful index for diagnosing PCL attenuation and lengthening in the presence of a normal morphological MR appearance.

  17. Isotopic fractionation in proteins as a measure of hydrogen bond length

    Energy Technology Data Exchange (ETDEWEB)

    McKenzie, Ross H., E-mail: r.mckenzie@uq.edu.au [School of Mathematics and Physics, University of Queensland, Brisbane 4072 (Australia); Athokpam, Bijyalaxmi; Ramesh, Sai G. [Department of Inorganic and Physical Chemistry, Indian Institute of Science, Bangalore 560 012 (India)

    2015-07-28

    If a deuterated molecule containing strong intramolecular hydrogen bonds is placed in a hydrogenated solvent, it may preferentially exchange deuterium for hydrogen. This preference is due to the difference between the vibrational zero-point energy for hydrogen and deuterium. It is found that the associated fractionation factor Φ is correlated with the strength of the intramolecular hydrogen bonds. This correlation has been used to determine the length of the H-bonds (donor-acceptor separation) in a diverse range of enzymes and has been argued to support the existence of short low-barrier H-bonds. Starting with a potential energy surface based on a simple diabatic state model for H-bonds, we calculate Φ as a function of the proton donor-acceptor distance R. For numerical results, we use a parameterization of the model for symmetric O–H⋯O bonds [R. H. McKenzie, Chem. Phys. Lett. 535, 196 (2012)]. We consider the relative contributions of the O–H stretch vibration, O–H bend vibrations (both in plane and out of plane), tunneling splitting effects at finite temperature, and the secondary geometric isotope effect. We compare our total Φ as a function of R with NMR experimental results for enzymes, and in particular with an earlier model parametrization Φ(R), used previously to determine bond lengths.

  18. A volumetric approach to path-length measurements is essential when treating radiotherapy with modulated beams.

    Science.gov (United States)

    Forde, Elizabeth; Booth, Jeremy; Leech, Michelle

    2014-01-01

    The established dosimetric benefits of intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy have lead to their increased use in prostate radiotherapy. Complimenting these techniques, volumetric image guidance has supported increased positional accuracy. In addition, 3-dimensional image guidance has also allowed for assessment of potential dosimetric variation that can be attributed to a deformation of either internal or external structures, such as rectal distension or body contour. Compounding these issues is the variation of tissue density through which the new field position passes and also the variation of dose across a modulated beam. Despite the growing level of interest in this area, there are only a limited number of articles that examine the effect of a variation in beam path length, particularly across a modulated field. IMRT and volumetric-modulated radiation therapy (VMAT) fields are dynamic in nature, and the dose gradient within these fields is variable. Assessment of variation of path length away from the beam׳s central axis and across the entire field is vital where there is considerable variation of dose within the field, such as IMRT and VMAT. In these cases, reliance on the traditional central axis to focus skin distances is no longer appropriate. This article discusses these more subtle challenges that may have a significant clinical effect if left unrecognized and undervalued. Copyright © 2014 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  19. Do focal colors look particularly "colorful"?

    Science.gov (United States)

    Witzel, Christoph; Franklin, Anna

    2014-04-01

    If the most typical red, yellow, green, and blue were particularly colorful (i.e., saturated), they would "jump out to the eye." This would explain why even fundamentally different languages have distinct color terms for these focal colors, and why unique hues play a prominent role in subjective color appearance. In this study, the subjective saturation of 10 colors around each of these focal colors was measured through a pairwise matching task. Results show that subjective saturation changes systematically across hues in a way that is strongly correlated to the visual gamut, and exponentially related to sensitivity but not to focal colors.

  20. The Accuracy of the Digital imaging system and the frequency dependent type apex locator in root canal length measurement

    International Nuclear Information System (INIS)

    Lee, Byoung Rib; Park, Chang Seo

    1998-01-01

    In order to achieve a successful endodontic treatment, root canals must be obturated three-dimensionally without causing any damage to apical tissues. Accurate length determination of the root canal is critical in this case. For this reason, I've used the conventional periapical radiography, Digora (digital imaging system) and Root ZX (the frequency dependent type apex locator) to measure the length of the canal and compare it with the true length obtained by cutting the tooth in half and measuring the length between the occlusal surface and the apical foramen. From the information obtained by these measurements, I was able to evaluate the accuracy and clinical usefulness of each systems, whether the thickness of files used in endodontic therapy has any effect on the measuring systems was also evaluated in an effort to simplify the treatment planning phase of endodontic treatment. 29 canals of 29 sound premolars were measured with no 15, no 20, no 25 files by 3 different dentists each using the periapical radiography, Digora and Root ZX. The measurements were then compared with the true length. The results were as follows ; 1. In comparing mean discrepancies between measurements obtained by using periapical radiography (mean error : -0.449 ± 0.444 mm), Digora (mean error : -0.417 ± 0.415 mm) and Root ZX (mean error : 0.123 ± 0.458 mm) with true length, periapical radiography and Digora system had statistically significant differences (p 0.05). 2. By subtracting values obtained by using periapical radiography, Digora and Root ZX from the true length and making a distribution table of their absolute values, the following analysis was possible. In the case of periapical film, 140 out of 261 (53.6%) were clinically acceptable satisfying the margin of error of less than 0.5 mm, 151 out of 261 (53,6%) were acceptable in the Digora system while Root ZX had 197 out of 261 (75.5%) within the limits of 0.5 mm margin of error. 3. In determining whether the thickness of

  1. The Accuracy of the Digital imaging system and the frequency dependent type apex locator in root canal length measurement

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Byoung Rib; Park, Chang Seo [Dept. of Dental Radiology, College of Dentistry, Yensei University, Seoul (Korea, Republic of)

    1998-08-15

    In order to achieve a successful endodontic treatment, root canals must be obturated three-dimensionally without causing any damage to apical tissues. Accurate length determination of the root canal is critical in this case. For this reason, I've used the conventional periapical radiography, Digora (digital imaging system) and Root ZX (the frequency dependent type apex locator) to measure the length of the canal and compare it with the true length obtained by cutting the tooth in half and measuring the length between the occlusal surface and the apical foramen. From the information obtained by these measurements, I was able to evaluate the accuracy and clinical usefulness of each systems, whether the thickness of files used in endodontic therapy has any effect on the measuring systems was also evaluated in an effort to simplify the treatment planning phase of endodontic treatment. 29 canals of 29 sound premolars were measured with no 15, no 20, no 25 files by 3 different dentists each using the periapical radiography, Digora and Root ZX. The measurements were then compared with the true length. The results were as follows; 1. In comparing mean discrepancies between measurements obtained by using periapical radiography (mean error : -0.449 {+-} 0.444 mm), Digora (mean error : -0.417 {+-} 0.415 mm) and Root ZX (mean error : 0.123 {+-} 0.458 mm) with true length, periapical radiography and Digora system had statistically significant differences (p<0.05) in most cases while root zx showed none (p>0.05). 2. By subtracting values obtained by using periapical radiography, Digora and Root ZX from the true length and making a distribution table of their absolute values, the following analysis was possible. In the case of periapical film, 140 out of 261 (53.6%) were clinically acceptable satisfying the margin of error of less than 0.5 mm, 151 out of 261 (53,6%) were acceptable in the Digora system while Root ZX had 197 out of 261 (75.5%) within the limits of 0.5 mm

  2. Voxel effects within digital images of trabecular bone and their consequences on chord-length distribution measurements

    International Nuclear Information System (INIS)

    Rajon, D.A.; Shah, A.P.; Watchman, C.J.; Bolch, W.E.; Jokisch, D.W.; Patton, P.W.

    2002-01-01

    Chord-length distributions through the trabecular regions of the skeleton have been investigated since the early 1960s. These distributions have become important features for bone marrow dosimetry; as such, current models rely on the accuracy of their measurements. Recent techniques utilize nuclear magnetic resonance (NMR) microscopy to acquire 3D images of trabecular bone that are then used to measure 3D chord-length distributions by Monte Carlo methods. Previous studies have shown that two voxel effects largely affect the acquisition of these distributions within digital images. One is particularly pertinent as it dramatically changes the shape of the distribution and reduces its mean. An attempt was made to reduce this undesirable effect and good results were obtained for a single-sphere model using minimum acceptable chord (MAC) methods (Jokisch et al 2001 Med. Phys. 28 1493-504). The goal of the present work is to extend the study of these methods to more general models in order to better quantify their consequences. First, a mathematical model of a trabecular bone sample was used to test the usefulness of the MAC methods. The results showed that these methods were not efficient for this simulated bone model. These methods were further tested on a single voxelized sphere over a large range of voxel sizes. The results showed that the MAC methods are voxel-size dependent and overestimate the mean chord length for typical resolutions used with NMR microscopy. The study further suggests that bone and marrow chord-length distributions currently utilized in skeletal dosimetry models are most likely affected by voxel effects that yield values of mean chord length lower than their true values. (author)

  3. Modeling the effect of probe force on length measurements on polymer parts

    DEFF Research Database (Denmark)

    Mohammadi, Ali; Sonne, Mads Rostgaard; Dalla Costa, Giuseppe

    2016-01-01

    Measurement uncertainty at micrometer level is in the future going to be very common in dimensional measurements on polymer parts. Accurate dimensional measurement of polymer parts is becoming a key and common practice in the industry, especially when micrometer tolerances are required. When...... numerically. Both analytical and numerical approaches were compared with the experimental results. The results showed that the numerical model was able to predict the deformation of the polymer part due to different probe forces. Furthermore it was shown, that the probe force should be taking into account...... when measurement with a few micrometer accuracy should be performed on thin walled polymer parts....

  4. 'Length'at Length

    Indian Academy of Sciences (India)

    Admin

    He was interested to know how `large' is the set of numbers x for which the series is convergent. Here large refers to its length. But his set is not in the class ♢. Here is another problem discussed by Borel. Consider .... have an infinite collection of pairs of new shoes and want to choose one shoe from each pair. We have an ...

  5. The measurement of cholinesterase activities as a biomarker in chub (Leuciscus cephalus): the fish length should not be ignored

    Energy Technology Data Exchange (ETDEWEB)

    Flammarion, P.; Noury, P.; Garric, J

    2002-12-01

    The fish length should be considered within the statistical analysis of ChE activities in chub species. - Biomarkers are early warning systems of the exposure of aquatic organisms to pollutants. Among them, the measurement of the cholinesterase (ChE) activities in fish muscle is a biomarker of the exposure to organophosphosphates and carbamates pesticides. As such it has been used in numerous field studies both in marine and continental waters. Cyprinids (chub, Leuciscus cephalus) were sampled in river sites (France) in relatively clean and polluted areas. We performed the statistical analysis of the ChE activities and we generally observed a statistical relationship between ChE activities and fish length, the larger fish having the lower ChE activities. We concluded that the great majority of the significant differences in ChE activities between sites could be due in fact to differences in fish length between field samples. We stress the importance of taking into account the fish length whenever differences in ChE levels between field sites must be interpreted.

  6. Actively cooled pump limiters and power scrape-off length measurements in Tore-Supra

    International Nuclear Information System (INIS)

    Guilhem, D.; Seigneur, A.; Chappuis, P.; Chatelier, M.; DeMichelis, C.; Deschamps, P.; Grosman, A.; Hess, W.; Lecoustey, P.; Loarer, T.; Poutchy, L.; Schlosser, J.

    1992-01-01

    TORE-SUPRA is a superconducting Tokamak aimed at studying long plasma pulses (>30 s). It is equipped with two types of pump limiters (PL). A provisional type, semi-inertially cooled between shots, has been used for plasma scrape off characterization. The e-folding length λq for power deposition on these components has been unfolded (1.0cm 19 m -3 19 m -3 ), of power level up to 4 MW and of toroidal magnetic field (1.5 T -1/2 ). The second type used for long pulse operation, is actively cooled during shots, its thermal time constant being less than 2 seconds. Experiments using this ITER relevant technology are presented. Three of the actively cooled limiters have been successfully tested in a steady state regime with a surface temperature less than 1000 deg C (I p =1.6 MA). The design value for power removal on this type of limiters has been obtained. Peak power fluxes of 10 MW/m 2 have been estimated. This represents a breakthrough for high heat flux components since critical heat flux and burnout with subcooled flow boiling are major aspects for this kind of design

  7. Experimental Focal Cerebral Ischemia

    DEFF Research Database (Denmark)

    Christensen, Thomas

    2007-01-01

    Focal cerebral ischemia due to occlusion of a major cerebral artery is the cause of ischemic stroke which is a major reason of mortality, morbidity and disability in the populations of the developed countries. In the seven studies summarized in the thesis focal ischemia in rats induced by occlusion...... in the penumbra is recruited in the infarction process leading to a progressive growth of the infarct. The penumbra hence constitutes an important target for pharmacological treatment because of the existence of a therapeutic time window during which treatment with neuroprotective compounds may prevent...

  8. An evaluation of deep-sea benthic megafauna length measurements obtained with laser and stereo camera methods

    Science.gov (United States)

    Dunlop, Katherine M.; Kuhnz, Linda A.; Ruhl, Henry A.; Huffard, Christine L.; Caress, David W.; Henthorn, Richard G.; Hobson, Brett W.; McGill, Paul; Smith, Kenneth L.

    2015-02-01

    The 25 year time-series collected at Station M, ~4000 m on the Monterey Deep-sea Fan, has substantially improved understanding of the role of the deep-ocean benthic environment in the global carbon cycle. However, the role of deep-ocean benthic megafauna in carbon bioturbation, remineralization and sequestration is relatively unknown. It is important to gather both accurate and precise measurements of megafaunal community abundance, size distribution and biomass to further define their role in deep-sea carbon cycling and possible sequestration. This study describes initial results from a stereo camera system attached to a remotely operated vehicle and analyzed using the EventMeasure photogrammetric measurement software to estimate the density, length and biomass of 10 species of mobile epibenthic megafauna. Stereo length estimates were compared to those from a single video camera system equipped with sizing lasers and analyzed using the Monterey Bay Aquarium Research Institute's Video Annotation and Reference System. Both camera systems and software were capable of high measurement accuracy and precision (megafauna species studied. The stereo image analysis process took substantially longer than the video analysis and the value of the EventMeasure software tool would be improved with developments in analysis automation. The stereo system is less influenced by object orientation and height, and is potentially a useful tool to be mounted on an autonomous underwater vehicle and for measuring deep-sea pelagic animals where the use of lasers is not feasible.

  9. Acoustic Scattering by Axisymmetric Finite-Length Bodies with Application to Fish: Measurement and Modeling

    National Research Council Canada - National Science Library

    Reeder, D

    2002-01-01

    ... laboratory acoustic measurements. A general acoustic scattering model is developed that is accurate and numerically efficient for a wide range of frequencies, angles of orientation, irregular axisymmetric shapes and boundary...

  10. Q-FISH measurement of hepatocyte telomere lengths in donor liver and graft after pediatric living-donor liver transplantation: donor age affects telomere length sustainability.

    Directory of Open Access Journals (Sweden)

    Youichi Kawano

    Full Text Available Along with the increasing need for living-donor liver transplantation (LDLT, the issue of organ shortage has become a serious problem. Therefore, the use of organs from elderly donors has been increasing. While the short-term results of LDLT have greatly improved, problems affecting the long-term outcome of transplant patients remain unsolved. Furthermore, since contradictory data have been reported with regard to the relationship between donor age and LT/LDLT outcome, the question of whether the use of elderly donors influences the long-term outcome of a graft after LT/LDLT remains unsettled. To address whether hepatocyte telomere length reflects the outcome of LDLT, we analyzed the telomere lengths of hepatocytes in informative biopsy samples from 12 paired donors and recipients (grafts of pediatric LDLT more than 5 years after adult-to-child LDLT because of primary biliary atresia, using quantitative fluorescence in situ hybridization (Q-FISH. The telomere lengths in the paired samples showed a robust relationship between the donor and grafted hepatocytes (r = 0.765, p = 0.0038, demonstrating the feasibility of our Q-FISH method for cell-specific evaluation. While 8 pairs showed no significant difference between the telomere lengths for the donor and the recipient, the other 4 pairs showed significantly shorter telomeres in the recipient than in the donor. Multiple regression analysis revealed that the donors in the latter group were older than those in the former (p = 0.001. Despite the small number of subjects, this pilot study indicates that donor age is a crucial factor affecting telomere length sustainability in hepatocytes after pediatric LDLT, and that the telomeres in grafted livers may be elongated somewhat longer when the grafts are immunologically well controlled.

  11. Path-length-resolved measurements of multiple scattered photons in static and dynamic turbid media using phase-modulated low-coherence interferometry

    NARCIS (Netherlands)

    Varghese, Babu; Rajan, Vinayakrishnan; van Leeuwen, Ton G.; Steenbergen, Wiendelt

    2007-01-01

    In optical Doppler measurements, the path length of the light is unknown. To facilitate quantitative measurements, we develop a phase-modulated Mach-Zehnder interferometer with separate fibers for illumination and detection. With this setup, path-length-resolved dynamic light scattering measurements

  12. Establishment of a method to measure length of the ulnar nerve and standardize F-wave values in clinically normal beagles.

    Science.gov (United States)

    Hirasawa, Shun; Shimizu, Miki; Marui, Yuumi; Kishimoto, Miori; Okuno, Seiichi

    2014-12-01

    We designed a new method of measuring the length of the ulnar nerve and determining standard values for F-wave parameters of the ulnar nerve in clinically normal beagles. Nerve length must be precisely measured to determine F-wave latency and conduction velocity. The length of the forelimb has served as the length of the ulnar nerve for F-wave assessments, but report indicates that F-wave latency is proportional to the length of the pathway traveled by nerve impulses. Therefore, we measured the surface distance from a stimulus point to the spinous process of the first thoracic vertebra (nerve length 1) and the anterior horn of the scapula (nerve length 2) as landmarks through the olecranon and the shoulder blade acromion. The correlation coefficients between the shortest F-wave latency and the length of nerves 1, 2 or the forelimb were 0.61, 0.7 and 0.58. Nerve length 2 generated the highest value. Furthermore, the anterior horn of the scapula was easily palpated in any dog regardless of well-fed body. We concluded that nerve length 2 was optimal for measuring the length of the ulnar nerve.

  13. Path length dependence of jet quenching measured with ALICE at the LHC

    NARCIS (Netherlands)

    Bertens, R.A.

    2016-01-01

    Jets are used to probe the quark-gluon plasma (QGP) that is created in heavy-ion collisions, by using the fact that medium-induced parton energy loss from elastic and radiative interactions between partons and the QGP lead to a modification of the measured jet spectrum. The dependence of the energy

  14. Life expectancy: complex measures of the length and the health related quality of life

    Directory of Open Access Journals (Sweden)

    Daniele Spizzichino

    2008-06-01

    Full Text Available

    Background: Life expectancy is one of the most frequently used indicators to assess mortality and the health of a population. It is a synthetic measure of mortality, which has the advantage of allowing for comparisons over time and between different groups, while eliminating the influence of the age structure of the population. Life expectancy has the advantage of being very easy to understand, although it needs to be interpreted within the context of the complex system of hypothesis that generates it. This is even more important for health expectancies and health gap measures, which are synthetic indicators that take into account both survival and health condition of a population.

    Methods: It is given a description of the most frequently used methods to calculate life expectancy, health expectancies and health gap measures. Measures of health expectancy are disability free life expectancy and healthy life expectancy. As health gap measures, frequently are used DALYs (Disability Adjusted Life Years.

    Discussion: There are various bodies and central government agencies that either have management data or carry out statistical systematic surveys and disability surveys. Statistically speaking, the worst aspect of this scenario is that it creates confusion and uncertainty among the end users of this data, namely the policy makers. At an international level the statistical data on disability is scarcely comparable among countries, despite huge efforts on the part of international organisations to harmonize classifications and definitions of disability.

    Results and Conclusions: There are several methods to compute life expectancy, each of these has some advantages and some disadvantages. Usually life expectancy is used also to account for the health status of population. Actually with the growing role of chronic and degenerative diseases, the increased number of

  15. Cervical length measurement in nulliparous women at term by ultrasound & its relationship to spontaneous onset of labour.

    Science.gov (United States)

    Mukherji, Joydev; Bhadra, Avishek; Ghosh, Suhas Kumar; Hazra, Avijit; Anant, Monika; Bhattacharya, Subir Kumar; Das, Bibekananda; Banu, Shabnam

    2017-10-01

    Data on serial cervical length (CL) measurements in pregnancy at term to predict spontaneous labour onset are scarce and conflicting. This study was conducted to observe CL changes preceding spontaneous onset of labour, by serial transvaginal sonography (TVS) and transabdominal sonography (TAS), in nulliparous Indian women near term. Only nulliparous women with a singleton foetus in cephalic presentation and who confirmed their gestational age were recruited. Sonographic CL measurements were taken at weekly intervals from 36 wk gestation onwards by a single ultrasonologist. Transabdominal and transvaginal measurements were undertaken using the suitable transducer probes with the women in the supine position. A total of 104 women with spontaneous onset of labour were evaluated. There was substantial variation in CL measurements, both by TVS and by TAS, from 36 to 40 wk gestation, although the two sets of measurements correlated closely. Mean CL changed significantly over the last three weeks before delivery. However, only one-third of the women showed CL change of >5 mm per week in the last three weeks. There was poor correlation between gestational age at delivery and the last measured CL, either by TVS or TAS. Length >3.1 mm, measured by TVS at 38 wk gestation, predicted post-dated pregnancy to a limited extent. Inter-individual variations in CL and in CL changes were large. Thus, it was not practical to predict spontaneous onset of labour by sonographic CL measurement near term. Post-dated pregnancy may be predicted with limited success. Further studies should explore other parameters, in addition to CL.

  16. Optical absorption coefficient and minority carrier diffusion length measurements in low-cost silicon solar cell material

    Energy Technology Data Exchange (ETDEWEB)

    Swimm, R.T.; Dumas, K.A.

    1982-11-01

    The optical absorption coefficient of silicon solar cell material grown by three low-cost growth methods was measured in the wavelength interval 0.8< or =lambda< or =1.0 ..mu..m, the wavelength region of interest in surface photovoltage measurements of the minority carrier diffusion length. The square root of the absorption coefficient was found to vary linearly with photon energy over the wavelengths studied, and the measured data agree with a linear empirical fit to within 0.5% RMS. The absorption coefficients obtained are slightly lower than those reported by Runyan, with the greatest disagreement at long wavelengths. Minority carrier diffusion lengths computed using the present absorption coefficients are approximately 16% greater than those calculated using Runyan's data. Excellent sample-to-sample agreement within and between lots indicates that for two of the growth methods studied, material quality as judged by optical properties has not been sacrificed by the use of low-cost growth methods. Samples grown by the third growth method studied showed measurably poorer optical quality.

  17. Noise Suppression on the Tunable Laser for Precise Cavity Length Displacement Measurement

    Czech Academy of Sciences Publication Activity Database

    Šmíd, Radek; Čížek, Martin; Mikel, Břetislav; Hrabina, Jan; Lazar, Josef; Číp, Ondřej

    2016-01-01

    Roč. 16, č. 9 (2016), 1428:1-11 ISSN 1424-8220 R&D Projects: GA ČR(CZ) GPP102/12/P962; GA ČR GB14-36681G; GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : Fabry-Perot cavity * unbalance Michelson interferometer * noise suppression * heterodyne interferometry * displacement measurement Subject RIV: BH - Optics, Masers, Lasers Impact factor: 2.677, year: 2016

  18. Development of a Data Reduction Algorithm for Optical Wide Field Patrol (OWL) II: Improving Measurement of Lengths of Detected Streaks

    Science.gov (United States)

    Park, Sun-Youp; Choi, Jin; Roh, Dong-Goo; Park, Maru; Jo, Jung Hyun; Yim, Hong-Suh; Park, Young-Sik; Bae, Young-Ho; Park, Jang-Hyun; Moon, Hong-Kyu; Choi, Young-Jun; Cho, Sungki; Choi, Eun-Jung

    2016-09-01

    As described in the previous paper (Park et al. 2013), the detector subsystem of optical wide-field patrol (OWL) provides many observational data points of a single artificial satellite or space debris in the form of small streaks, using a chopper system and a time tagger. The position and the corresponding time data are matched assuming that the length of a streak on the CCD frame is proportional to the time duration of the exposure during which the chopper blades do not obscure the CCD window. In the previous study, however, the length was measured using the diagonal of the rectangle of the image area containing the streak; the results were quite ambiguous and inaccurate, allowing possible matching error of positions and time data. Furthermore, because only one (position, time) data point is created from one streak, the efficiency of the observation decreases. To define the length of a streak correctly, it is important to locate the endpoints of a streak. In this paper, a method using a differential convolution mask pattern is tested. This method can be used to obtain the positions where the pixel values are changed sharply. These endpoints can be regarded as directly detected positional data, and the number of data points is doubled by this result.

  19. An Experimental Measurement on Laminar Burning Velocities and Markstein Length of Iso-Butane-Air Mixtures at Ambient Conditions

    Directory of Open Access Journals (Sweden)

    Yousif Alaeldeen Altag

    2016-01-01

    Full Text Available In the present work, experimental investigation on laminar combustion of iso-butane-air mixtures was conducted in constant volume explosion vessel. The experiments were conducted at wide range of equivalence ratios ranging between Ф = 0.6 and 1.4 and atmospheric pressure of 0.1 MPa and ambient temperature of 303K. Using spherically expanding flame method, flame parameters including stretched, unstretched flame propagation speeds, laminar burning velocities and Markstein length were calculated. For laminar burning velocities the method of error bars of 95% confidence level was applied. In addition, values of Markstein lengths were measured in wide range of equivalence ratios to study the influence of stretch rate on flame instability and burning velocity. It was found that the stretched flame speed and laminar burning velocities increased with equivalence ratios and the peak value was obtained at equivalence ratio of Ф = 1.1. The Markstein length decreased with the increases in equivalence ratios, which indicates that the diffusion thermal flame instability increased at high equivalence ratios in richer mixture side. However, the total deviations in the laminar burning velocities have discrepancies of 1.2-2.9% for all investigated mixtures.

  20. The effects of social status on biological aging as measured by white-blood-cell telomere length.

    Science.gov (United States)

    Cherkas, L F; Aviv, A; Valdes, A M; Hunkin, J L; Gardner, J P; Surdulescu, G L; Kimura, M; Spector, T D

    2006-10-01

    Low socio-economic status (SES) is associated with a shortened life expectancy, but its effect on aging is unknown. The rate of white-blood-cell (WBC) telomere attrition may be a biological indicator of human aging. We tested the hypothesis that SES is associated with telomere attrition independent of known risk factors influencing the aging process. We studied 1552 female twins. A venous blood sample was taken from each twin and isolated WBCs used for extraction of DNA. Terminal restriction fragment length (TRFL) was measured. Questionnaire data were collected on occupation, education, income, smoking, exercise, height and weight. Standard multiple linear regression and multivariate analyses of variance tested for associations between SES and TRFL, adjusting for covariates. A discordant twin analysis was conducted on a subset to verify findings. WBC telomere length was highly variable but significantly shorter in lower SES groups. The mean difference in TRFL between nonmanual and manual SES groups was 163.2 base pairs (bp) of which 22.9 bp (approximately 14%) was accounted for by body mass index, smoking and exercise. Comparison of TRFL in the 17 most discordant SES twin pairs confirmed this difference. Low SES, in addition to the harmful effects of smoking, obesity and lack of exercise, appears to have an impact on telomere length.

  1. LEARNING ONE-DIGIT DECIMAL NUMBERS BY MEASUREMENT AND GAME PREDICTING LENGTH

    Directory of Open Access Journals (Sweden)

    Puji Astuti

    2014-01-01

    Full Text Available This paper aims to describe how students develop understanding of one-digit decimals. To achieve the aim, Local Instruction Theory (LIT about the process of learning decimals and the means designed to support that learning are developed. Along with this idea, the framework of Realistic Mathematics Education (RME is proposed. Based on the aim, design research methodology is used. This paper discusses learning activities of three meetings from teaching experiment of the focus group students of the fourth grade elementary school in Surabaya: SDIT Al Ghilmani. The data indicated that the learning activities promoted the students’ understanding of one-digit decimal numbers.Keyword: measurement, decimal numbers, number line DOI: http://dx.doi.org/10.22342/jme.5.1.1447.35-46

  2. Effect of working length measurement by electronic apex locator or digital radiography on postoperative pain: a randomized clinical trial.

    Science.gov (United States)

    Kara Tuncer, Aysun; Gerek, Müzeyyen

    2014-01-01

    The aim of this study was to evaluate the effect of working length determination methods, electronic apex locator and digital radiography, on postoperative pain. Two hundred twenty patients with asymptomatic single-rooted vital teeth were randomly assigned to 2 groups according to the method used for working length determination, the radiographic group and the electronic apex locator group. After working length determination, chemomechanical preparation was performed in a crown-down technique with ProTaper instruments. A master cone radiograph was taken. Canals were obturated with gutta-percha and sealer by using a lateral compaction technique. Postoperative pain was assessed after 4, 6, 12, 24, and 48 hours by using a 4-point pain intensity scale. In addition, patients were asked to record the number of days necessary to achieve complete pain resolution. Postoperative pain during the 4-hour to 48-hour interval studied was not significantly different (P > .05) between groups. The mean times for pain dissipation in the radiographic and electronic apex locator groups were 3.37 ± 2.79 and 3.88 ± 3.34 days, respectively. The difference between groups was not statistically significant (P > .05). There is no difference in postoperative pain between working length measurement methods by using an electronic apex locator or digital radiography. The reduced exposure to radiation by using apex locator may be a factor that influences a dentist's decision to choose the electronic apex locator over radiography. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  3. Axial Length Variation Impacts on Superficial Retinal Vessel Density and Foveal Avascular Zone Area Measurements Using Optical Coherence Tomography Angiography.

    Science.gov (United States)

    Sampson, Danuta M; Gong, Peijun; An, Di; Menghini, Moreno; Hansen, Alex; Mackey, David A; Sampson, David D; Chen, Fred K

    2017-06-01

    To evaluate the impact of image magnification correction on superficial retinal vessel density (SRVD) and foveal avascular zone area (FAZA) measurements using optical coherence tomography angiography (OCTA). Participants with healthy retinas were recruited for ocular biometry, refraction, and RTVue XR Avanti OCTA imaging with the 3 × 3-mm protocol. The foveal and parafoveal SRVD and FAZA were quantified with custom software before and after correction for magnification error using the Littman and the modified Bennett formulae. Relative changes between corrected and uncorrected SRVD and FAZA were calculated. Forty subjects were enrolled and the median (range) age of the participants was 30 (18-74) years. The mean (range) spherical equivalent refractive error was -1.65 (-8.00 to +4.88) diopters and mean (range) axial length was 24.42 mm (21.27-28.85). Images from 13 eyes were excluded due to poor image quality leaving 67 for analysis. Relative changes in foveal and parafoveal SRVD and FAZA after correction ranged from -20% to +10%, -3% to +2%, and -20% to +51%, respectively. Image size correction in measurements of foveal SRVD and FAZA was greater than 5% in 51% and 74% of eyes, respectively. In contrast, 100% of eyes had less than 5% correction in measurements of parafoveal SRVD. Ocular biometry should be performed with OCTA to correct image magnification error induced by axial length variation. We advise caution when interpreting interocular and interindividual comparisons of SRVD and FAZA derived from OCTA without image size correction.

  4. On the frequency distributions per unit area of the projected and etchable lengths of surface-intersecting fission tracks: influences of track revelation, observation and measurement

    CERN Document Server

    Jonckheere, R

    1999-01-01

    In addition to the statistical bounds discussed, thermal history analysis based on the projected and etchable length distributions of surface intersecting fission tracks is limited by systematic factors related to track revelation, observation and measurement. The effects of track revelation, in particular, distort these distributions in the length intervals of interest. An observation threshold poses a problem if it is described by a critical angle theta sub c , but not if it is described by other criteria proposed in the literature. Measurement imprecisions, predictably, blur the thermal history information contained in these distributions. Measurements of semi-confined tracks, added as a result of surface etching, are a more promising alternative to confined track length measurements for accessing the thermal history record in the fission track length distribution. On the other hand, measurements of the projected lengths of surface intersecting tracks offer the theoretical possibility of determining the tr...

  5. Central Sensitization Inventory as a Predictor of Worse Quality of Life Measures and Increased Length of Stay Following Spinal Fusion.

    Science.gov (United States)

    Bennett, E Emily; Walsh, Kevin M; Thompson, Nicolas R; Krishnaney, Ajit A

    2017-08-01

    Central sensitization is abnormal and intense enhancement of pain mechanism by the central nervous system. Patients with central sensitization may be at higher risk of poor outcomes after spinal fusion. The Central Sensitivity Inventory (CSI) was developed to identify and quantify key symptoms related to central sensitization. In 664 patients who underwent thoracic and/or lumbar fusion, we evaluated retrospectively pretreatment CSI as a predictor of postoperative quality of life measures, length of stay, and discharge status. Preoperative Pain Disability Questionnaire scores, Patient Health Questionnaire-9 scores, and EuroQol-5 Dimensions index scores were significantly worse in patients with preoperative CSI ≥40 compared with patients with preoperative CSI <40 (P < 0.0001 for all). After adjusting for demographic variables, operation duration, and preoperative health status, preoperative CSI was significantly associated with higher postoperative Pain Disability Questionnaire total score (unadjusted P < 0.001, adjusted P = 0.009), higher postoperative Patient Health Questionnaire-9 score (unadjusted P < 0.001, adjusted P = 0.001), and lower postoperative EuroQol-5 Dimensions index (unadjusted P < 0.001, adjusted P = 0.001). For each 10-unit increase in CSI, average length of stay increased by 6.4% (95% confidence interval 0.4%-12.6%, P = 0.035). The odds of being discharged home after adjusting for confounders was not statistically related to preoperative CSI (P = 0.0709). Preoperative CSI was associated with worse quality of life outcomes and increased length of stay after spinal fusions. CSI may be an additional measure in evaluating patients preoperatively to better predict successful spinal fusion outcomes. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. On the Quaternionic Focal Curves

    Directory of Open Access Journals (Sweden)

    Nurten (BAYRAK GÜRSES

    2017-06-01

    Full Text Available In this study, a brief summary about quaternions and quaternionic curves are firstly presented. Also, the definition of focal curve is given. The focal curve of a smooth curve consists of the centers of its osculating hypersphere.  By using this definition and the quaternionic osculating hyperspheres of these curves, the quaternionic focal curves in the spaces $\\Q$ and $\\Q_\

  7. Distribution of axial length and ocular biometry measured using partial coherence laser interferometry (IOL Master) in an older white population.

    Science.gov (United States)

    Fotedar, Reena; Wang, Jie Jin; Burlutsky, George; Morgan, Ian G; Rose, Kathryn; Wong, Tien Y; Mitchell, Paul

    2010-03-01

    We aimed to describe norms for the distribution of axial length (AL) and other ocular biometric parameters in an older Caucasian population, measured using partial coherence laser interferometry (Zeiss IOL Master; Carl Zeiss AG, Oberkochen, Germany), a technique now routinely used in measuring AL before cataract surgery. We also aimed to assess age and gender relationships with these parameters and their correlations with spherical equivalent refraction (SER). Cross-sectional analysis of the Blue Mountains Eye Study (BMES) cohort at the examinations (10-year follow-up examination). From 2002 to 2004, 1952 persons (76% of surviving baseline BMES participants) aged 59 years or older had ocular biometry measured at the 10-year examinations. Spherical equivalent refraction was calculated as the sum of sphere +0.5 cylinder power, after protocol refraction. Measurements of AL, corneal curvature (K1), anterior chamber depth (ACD), and corneal diameter (WTW) were performed using the IOL Master. Only right phakic eyes (n = 1335) with biometry data were included. Axial length distribution. Mean AL was 23.44 mm (95% confidence interval [CI], 23.38-23.50) and was greater in men, 23.76 mm (CI, 23.68-23.84), than in women, 23.19 mm (CI, 23.11-23.27). The mean K1, ACD, and WTW were 43.42 diopters (D), 3.10 mm, and 12.06 mm, respectively. The AL and ACD distributions were both positively skewed and peaked, whereas the WTW and K1 distributions were near normal. From age 59 years or older, a mean reduction in AL with age was observed (P for trend = 0.005), 0.12 mm per decade (P = 0.0176) in women but only 0.02 mm per decade (P = 0.6319) in men. Mean SER was 0.58 D, and the distribution was peaked with a negative skew. The SER was negatively correlated with both AL (beta coefficient -0.688) and ACD (beta coefficient -0.222), but not with K1 or WTW. These data provide normative values in the older general population for AL measured using the IOL Master. Axial length distribution was

  8. Weight and see: Line bisection in neglect reliably measures the allocation of attention, but not the perception of length.

    Science.gov (United States)

    McIntosh, Robert D; Ietswaart, Magdalena; Milner, A David

    2017-11-01

    Line bisection has long been a routine test for unilateral neglect, along with a range of tests requiring cancellation, copying or drawing. However, several studies have reported that line bisection, as classically administered, correlates relatively poorly with the other tests of neglect, to the extent that some authors have questioned its status as a valid test of neglect. In this article, we re-examine this issue, employing a novel method for administering and analysing line bisection proposed by McIntosh et al. (2005). We report that the measure of attentional bias yielded by this new method (EWB) correlates significantly more highly with cancellation, copying and drawing measures than the classical line bisection error measure in a sample of 50 right-brain damaged patients. Furthermore when EWB was combined with a second measure that emerges from the new analysis (EWS), even higher correlations were obtained. A Principal Components Analysis found that EWB loaded highly on a major factor representing neglect asymmetry, while EWS loaded on a second factor which we propose may measure overall attentional investment. Finally, we found that tests of horizontal length and size perception were related poorly to other measures of neglect in our group. We conclude that this novel approach to interpreting line bisection behaviour provides a promising way forward for understanding the nature of neglect. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  9. Precise NMR measurement and stabilization system of magnetic field of a superconducting 7 T wave length shifter

    CERN Document Server

    Borovikov, V M; Karpov, G V; Korshunov, D A; Kuper, E A; Kuzin, M V; Mamkin, V R; Medvedko, A S; Mezentsev, N A; Repkov, V V; Shkaruba, V A; Shubin, E I; Veremeenko, V F

    2001-01-01

    The system of measurement and stabilization of the magnetic field in the superconducting 7 T wave length shifter (WLS), designed at Budker Institute of Nuclear Physics are described. The measurements are performed by nuclear magnetic resonance (NMR) magnetometer at two points of the WLS magnetic field. Stabilization of the field is provided by the current pumping system. The stabilization system is based on precise NMR measurement of magnetic field as a feedback signal for computer code which control currents inside the superconducting coils. The problem of the magnetic field measurements with NMR method consists in wide spread of field in the measured area (up to 50 Gs/mm), wide temperature range of WLS operating, small space for probe and influence of iron hysteresis. Special solid-state probes were designed to satisfy this requirements. The accuracy of magnetic field measurements at probe locations is not worse than 20 ppm. For the WLS field of 7 T the reproducibility of the magnetic field of 30 ppm has be...

  10. On-line qualification of a micro probing system for precision length measurement of micro-features on precision parts

    International Nuclear Information System (INIS)

    Chen, Yuan-Liu; Ito, So; Kikuchi, Hirotaka; Kobayashi, Ryo; Shimizu, Yuki; Gao, Wei

    2016-01-01

    This paper presents on-line qualification of the effective diameter of the micro-stylus tip ball of a micro probing system for precision length measurement of micro-features on precision parts by utilizing a set of gauge blocks as the qualification artefact, which is composed by one calibrated gauge block and two supporting gauge blocks that are wrung together for a good mechanical stability. The qualification artefact is aligned side by side with the precision part to be measured for enabling a rapid transfer between the qualification step of the probe two-point tip ball diameter and the length measurement step of the precision part. Based on the proposed setup, on-line qualifications of a micro-stylus with a nominal tip ball diameter of 52.6 μ m were carried out by using two methods referred to as Method A and Method B, respectively. Method A is operated by probing the opposite sides of the gap between the two supporting gauge blocks separated by the calibrated gauge block, and Method B is operated by probing the opposite sides of the calibrated gauge block supported by the two supporting gauge blocks. Intensive uncertainty analyses based on the experimental results and the geometrical models were carried out to compare the performances of these two methods. Method A, which was confirmed to be more accurate and faster than Method B, was then employed to measure the width of a micro-gap on a precision part with compensation of the determined effective two-point tip ball diameter. (paper)

  11. On-line qualification of a micro probing system for precision length measurement of micro-features on precision parts

    Science.gov (United States)

    Chen, Yuan-Liu; Ito, So; Kikuchi, Hirotaka; Kobayashi, Ryo; Shimizu, Yuki; Gao, Wei

    2016-07-01

    This paper presents on-line qualification of the effective diameter of the micro-stylus tip ball of a micro probing system for precision length measurement of micro-features on precision parts by utilizing a set of gauge blocks as the qualification artefact, which is composed by one calibrated gauge block and two supporting gauge blocks that are wrung together for a good mechanical stability. The qualification artefact is aligned side by side with the precision part to be measured for enabling a rapid transfer between the qualification step of the probe two-point tip ball diameter and the length measurement step of the precision part. Based on the proposed setup, on-line qualifications of a micro-stylus with a nominal tip ball diameter of 52.6 μm were carried out by using two methods referred to as Method A and Method B, respectively. Method A is operated by probing the opposite sides of the gap between the two supporting gauge blocks separated by the calibrated gauge block, and Method B is operated by probing the opposite sides of the calibrated gauge block supported by the two supporting gauge blocks. Intensive uncertainty analyses based on the experimental results and the geometrical models were carried out to compare the performances of these two methods. Method A, which was confirmed to be more accurate and faster than Method B, was then employed to measure the width of a micro-gap on a precision part with compensation of the determined effective two-point tip ball diameter.

  12. The accuracy of three-dimensional fused deposition modeling (FDM) compared with three-dimensional CT-Scans on the measurement of the mandibular ramus vertical length, gonion-menton length, and gonial angle

    Science.gov (United States)

    Savitri, I. T.; Badri, C.; Sulistyani, L. D.

    2017-08-01

    Presurgical treatment planning plays an important role in the reconstruction and correction of defects in the craniomaxillofacial region. The advance of solid freeform fabrication techniques has significantly improved the process of preparing a biomodel using computer-aided design and data from medical imaging. Many factors are implicated in the accuracy of the 3D model. To determine the accuracy of three-dimensional fused deposition modeling (FDM) models compared with three-dimensional CT scans in the measurement of the mandibular ramus vertical length, gonion-menton length, and gonial angle. Eight 3D models were produced from the CT scan data (DICOM file) of eight patients at the Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, University of Indonesia, Cipto Mangunkusumo Hospital. Three measurements were done three times by two examiners. The measurements of the 3D CT scans were made using OsiriX software, while the measurements of the 3D models were made using a digital caliper and goniometry. The measurement results were then compared. There is no significant difference between the measurements of the mandibular ramus vertical length, gonion-menton length, and gonial angle using 3D CT scans and FDM 3D models. FDM 3D models are considered accurate and are acceptable for clinical applications in dental and craniomaxillofacial surgery.

  13. Direct comparison of flow-FISH and qPCR as diagnostic tests for telomere length measurement in humans.

    Directory of Open Access Journals (Sweden)

    Fernanda Gutierrez-Rodrigues

    Full Text Available Telomere length measurement is an essential test for the diagnosis of telomeropathies, which are caused by excessive telomere erosion. Commonly used methods are terminal restriction fragment (TRF analysis by Southern blot, fluorescence in situ hybridization coupled with flow cytometry (flow-FISH, and quantitative PCR (qPCR. Although these methods have been used in the clinic, they have not been comprehensively compared. Here, we directly compared the performance of flow-FISH and qPCR to measure leukocytes' telomere length of healthy individuals and patients evaluated for telomeropathies, using TRF as standard. TRF and flow-FISH showed good agreement and correlation in the analysis of healthy subjects (R(2 = 0.60; p<0.0001 and patients (R(2 = 0.51; p<0.0001. In contrast, the comparison between TRF and qPCR yielded modest correlation for the analysis of samples of healthy individuals (R(2 = 0.35; p<0.0001 and low correlation for patients (R(2 = 0.20; p = 0.001; Bland-Altman analysis showed poor agreement between the two methods for both patients and controls. Quantitative PCR and flow-FISH modestly correlated in the analysis of healthy individuals (R(2 = 0.33; p<0.0001 and did not correlate in the comparison of patients' samples (R(2 = 0.1, p = 0.08. Intra-assay coefficient of variation (CV was similar for flow-FISH (10.8 ± 7.1% and qPCR (9.5 ± 7.4%; p = 0.35, but the inter-assay CV was lower for flow-FISH (9.6 ± 7.6% vs. 16 ± 19.5%; p = 0.02. Bland-Altman analysis indicated that flow-FISH was more precise and reproducible than qPCR. Flow-FISH and qPCR were sensitive (both 100% and specific (93% and 89%, respectively to distinguish very short telomeres. However, qPCR sensitivity (40% and specificity (63% to detect telomeres below the tenth percentile were lower compared to flow-FISH (80% sensitivity and 85% specificity. In the clinical setting, flow-FISH was more accurate, reproducible, sensitive, and specific in the measurement of human

  14. Windowing UWB microwave, mm-wave multi-port S-parameter measurements using open-ended excess electrical length

    Directory of Open Access Journals (Sweden)

    Gholamreza Askari

    2017-05-01

    Full Text Available Multi-port measurements are a big challenge in circuits' verification, especially when the frequency increases. This study presents a new technique for measuring S-parameters of multi-port ultra-wideband (UWB microwave and mm-wave circuits. The concepts are based on direct or indirect applying modulated UWB impulse radio in desired bandwidth to the one port of the modified multi-port circuit and gathering the reflected signal in the same port and the output signal in the second port in time domain, and the other ports are left opened with a special designed added electrical length. Then by applying intelligent windowing in time domain to the gathering data, and using fast Fourier transform, the desired S-parameters are extracted. Validation of this technique is verified by design and fabrication of a three-port UWB Wilkinson power divider in 22–30 GHz. The simulation and measurement results of the reflection and transmission S-parameters by using this new technique are very close to those are extracted with the conventional vector network analysers S-parameters measurements and show the ability and the accuracy of this technique.

  15. Method Specific Calibration Corrects for DNA Extraction Method Effects on Relative Telomere Length Measurements by Quantitative PCR.

    Science.gov (United States)

    Seeker, Luise A; Holland, Rebecca; Underwood, Sarah; Fairlie, Jennifer; Psifidi, Androniki; Ilska, Joanna J; Bagnall, Ainsley; Whitelaw, Bruce; Coffey, Mike; Banos, Georgios; Nussey, Daniel H

    2016-01-01

    Telomere length (TL) is increasingly being used as a biomarker in epidemiological, biomedical and ecological studies. A wide range of DNA extraction techniques have been used in telomere experiments and recent quantitative PCR (qPCR) based studies suggest that the choice of DNA extraction method may influence average relative TL (RTL) measurements. Such extraction method effects may limit the use of historically collected DNA samples extracted with different methods. However, if extraction method effects are systematic an extraction method specific (MS) calibrator might be able to correct for them, because systematic effects would influence the calibrator sample in the same way as all other samples. In the present study we tested whether leukocyte RTL in blood samples from Holstein Friesian cattle and Soay sheep measured by qPCR was influenced by DNA extraction method and whether MS calibration could account for any observed differences. We compared two silica membrane-based DNA extraction kits and a salting out method. All extraction methods were optimized to yield enough high quality DNA for TL measurement. In both species we found that silica membrane-based DNA extraction methods produced shorter RTL measurements than the non-membrane-based method when calibrated against an identical calibrator. However, these differences were not statistically detectable when a MS calibrator was used to calculate RTL. This approach produced RTL measurements that were highly correlated across extraction methods (r > 0.76) and had coefficients of variation lower than 10% across plates of identical samples extracted by different methods. Our results are consistent with previous findings that popular membrane-based DNA extraction methods may lead to shorter RTL measurements than non-membrane-based methods. However, we also demonstrate that these differences can be accounted for by using an extraction method-specific calibrator, offering researchers a simple means of accounting for

  16. Measuring the length distribution of self-assembled lipid nanotubes by orientation control with a high-frequency alternating current electric field in aqueous solutions.

    Science.gov (United States)

    Hirano, Ken; Aoyagi, Masaru; Ishido, Tomomi; Ooie, Toshihiko; Frusawa, Hiroshi; Asakawa, Masumi; Shimizu, Toshimi; Ishikawa, Mitsuru

    2009-02-15

    The present work addresses the length distribution of self-assembled lipid nanotubes (LNTs) by controlling the orientation of the LNTs using an alternating current (ac) electric field in aqueous solutions. The effect of the ac field on the orientation and rotation of individual LNTs was examined to evaluate the optimum orientation frequency by visualizing the individual LNTs in real time. By using the high-frequency ac field, we have successfully measured the length distribution for two different types of LNTs and have quantitatively analyzed the maximum occurrences of the length distribution as well as the extension of the longer length region.

  17. Reliability of the two-point measurement of the spatial correlation length from Gaussian-shaped fluctuating signals in fusion-grade plasmas

    Science.gov (United States)

    Kim, Jaewook; Nam, Y. U.; Lampert, M.; Ghim, Y.-C.

    2016-10-01

    A statistical method for the estimation of the spatial correlation lengths of Gaussian-shaped fluctuating signals with two measurement points is examined to quantitatively evaluate its reliability (variance) and accuracy (bias error). The standard deviation of the correlation value is analytically derived for randomly distributed Gaussian shaped fluctuations satisfying stationarity and homogeneity, allowing us to evaluate, as a function of fluctuation-to-noise ratios, the sizes of averaging time windows and the ratios of the distance between the two measurement points to the true correlation length, and the goodness of the two-point measurement for estimating the spatial correlation length. Analytic results are confirmed with numerically generated synthetic data and real experimental data obtained with the KSTAR beam emission spectroscopy diagnostic. Our results can be applied to Gaussian-shaped fluctuating signals where a correlation length must be measured with only two measurement points.

  18. Estimating age from recapture data: integrating incremental growth measures with ancillary data to infer age-at-length

    Science.gov (United States)

    Eaton, Mitchell J.; Link, William A.

    2011-01-01

    Estimating the age of individuals in wild populations can be of fundamental importance for answering ecological questions, modeling population demographics, and managing exploited or threatened species. Significant effort has been devoted to determining age through the use of growth annuli, secondary physical characteristics related to age, and growth models. Many species, however, either do not exhibit physical characteristics useful for independent age validation or are too rare to justify sacrificing a large number of individuals to establish the relationship between size and age. Length-at-age models are well represented in the fisheries and other wildlife management literature. Many of these models overlook variation in growth rates of individuals and consider growth parameters as population parameters. More recent models have taken advantage of hierarchical structuring of parameters and Bayesian inference methods to allow for variation among individuals as functions of environmental covariates or individual-specific random effects. Here, we describe hierarchical models in which growth curves vary as individual-specific stochastic processes, and we show how these models can be fit using capture–recapture data for animals of unknown age along with data for animals of known age. We combine these independent data sources in a Bayesian analysis, distinguishing natural variation (among and within individuals) from measurement error. We illustrate using data for African dwarf crocodiles, comparing von Bertalanffy and logistic growth models. The analysis provides the means of predicting crocodile age, given a single measurement of head length. The von Bertalanffy was much better supported than the logistic growth model and predicted that dwarf crocodiles grow from 19.4 cm total length at birth to 32.9 cm in the first year and 45.3 cm by the end of their second year. Based on the minimum size of females observed with hatchlings, reproductive maturity was estimated

  19. Measurement of the mass of the top quark using the transverse decay length and lepton transverse momentum techniques

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Christian

    2014-05-02

    A measurement of the mass of the top quark using the transverse momentum of the lepton and decay length of the B-Hadron has been presented. The result is m{sub Top}=(170.4±1.1{sub stat.}±2.3{sub syst.}) GeV. This is compatible with previous measurements of the mass of the top quark, done by either the ATLAS collaboration or other experiments. The total uncertainty on the result of this analysis, Δ{sup total}m{sub Top}=2.6 GeV is larger than results by other measurements. However, with an jet energy scale uncertainty of only Δ{sup Jes}m{sub Top}=0.3 GeV it has one of the smallest uncertainties caused by this source. In a combination of results this will help reducing the total uncertainty on the mass of the top quark. The value of 0.42 on the strength on final state radiation indicates that the simulation underestimates the strength of final state radiation. There is currently work ongoing aiming to publish the results found in this thesis in the context of an official ATLAS publication. Additionally the uncertainties can be compared with those one would obtain by using only one of the two variables. If one considers only the transverse decay length, a statistical error of Δm{sub Top}{sup stat.}=1.7 GeV and a systematic uncertainty of Δm{sub Top}{sup stat.}=7.8 GeV is obtained, dominated by the uncertainty on initial and final state radiation. The statistical uncertainty obtained by using the transverse momentum of the lepton is with Δm{sub Top}{sup stat.}=1.4 GeV a bit lower than the one obtained by the transverse decay length alone but still larger than the one of the presented measurement. The systematic uncertainty obtained is Δm{sub Top}{sup stat.}=2.7 GeV. Combining the two variables is therefore worthwhile compared with using only the transverse momentum of the lepton alone. The dominant uncertainties on the measurement are caused by imperfect knowledge of the simulation parameters, especially the choice of Monte-Carlo generator. Other large

  20. Correlation of Leukocyte Telomere Length Measurement Methods in Patients with Dyskeratosis Congenita and in Their Unaffected Relatives.

    Science.gov (United States)

    Khincha, Payal P; Dagnall, Casey L; Hicks, Belynda; Jones, Kristine; Aviv, Abraham; Kimura, Masayuki; Katki, Hormuzd; Aubert, Geraldine; Giri, Neelam; Alter, Blanche P; Savage, Sharon A; Gadalla, Shahinaz M

    2017-08-13

    Several methods have been employed to measure telomere length (TL) in human studies. It has been difficult to directly compare the results from these studies because of differences in the laboratory techniques and output parameters. We compared TL measurements (TLMs) by the three most commonly used methods, quantitative polymerase chain reaction (qPCR), flow cytometry with fluorescence in situ hybridization (flow FISH) and Southern blot, in a cohort of patients with the telomere biology disorder dyskeratosis congenita (DC) and in their unaffected relatives (controls). We observed a strong correlation between the Southern blot average TL and the flow FISH total lymphocyte TL in both the DC patients and their unaffected relatives ( R ² of 0.68 and 0.73, respectively). The correlation between the qPCR average TL and that of the Southern blot method was modest ( R ² of 0.54 in DC patients and of 0.43 in unaffected relatives). Similar results were noted when comparing the qPCR average TL and the flow FISH total lymphocyte TL ( R ² of 0.49 in DC patients and of 0.42 in unaffected relatives). In conclusion, the strengths of the correlations between the three widely used TL assays (qPCR, flow FISH, and Southern blot) were significantly different. Careful consideration is warranted when selecting the method of TL measurement for research and for clinical studies.

  1. Correlation of Leukocyte Telomere Length Measurement Methods in Patients with Dyskeratosis Congenita and in Their Unaffected Relatives

    Science.gov (United States)

    Khincha, Payal P.; Hicks, Belynda; Jones, Kristine; Aviv, Abraham; Kimura, Masayuki; Katki, Hormuzd; Aubert, Geraldine; Giri, Neelam; Alter, Blanche P.; Savage, Sharon A.; Gadalla, Shahinaz M.

    2017-01-01

    Several methods have been employed to measure telomere length (TL) in human studies. It has been difficult to directly compare the results from these studies because of differences in the laboratory techniques and output parameters. We compared TL measurements (TLMs) by the three most commonly used methods, quantitative polymerase chain reaction (qPCR), flow cytometry with fluorescence in situ hybridization (flow FISH) and Southern blot, in a cohort of patients with the telomere biology disorder dyskeratosis congenita (DC) and in their unaffected relatives (controls). We observed a strong correlation between the Southern blot average TL and the flow FISH total lymphocyte TL in both the DC patients and their unaffected relatives (R2 of 0.68 and 0.73, respectively). The correlation between the qPCR average TL and that of the Southern blot method was modest (R2 of 0.54 in DC patients and of 0.43 in unaffected relatives). Similar results were noted when comparing the qPCR average TL and the flow FISH total lymphocyte TL (R2 of 0.49 in DC patients and of 0.42 in unaffected relatives). In conclusion, the strengths of the correlations between the three widely used TL assays (qPCR, flow FISH, and Southern blot) were significantly different. Careful consideration is warranted when selecting the method of TL measurement for research and for clinical studies. PMID:28805708

  2. Optical Design of a Broadband Infrared Spectrometer for Bunch Length Measurement at the Linac Coherent Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Kiel; /SLAC

    2012-09-07

    The electron pulses generated by the Linac Coherent Light Source at the SLAC National Accelerator Laboratory occur on the order of tens of femtoseconds and cannot be directly measured by conventional means. The length of the pulses can instead be reconstructed by measuring the spectrum of optical transition radiation emitted by the electrons as they move toward a conducting foil. Because the emitted radiation occurs in the mid-infrared from 0.6 to 30 microns a novel optical layout is required. Using a helium-neon laser with wavelength 633 nm, a series of gold-coated off-axis parabolic mirrors were positioned to direct a beam through a zinc selenide prism and to a focus at a CCD camera for imaging. Constructing this layout revealed a number of novel techniques for reducing the aberrations introduced into the system by the off-axis parabolic mirrors. The beam had a recorded radius of less than a millimeter at its final focus on the CCD imager. This preliminary setup serves as a model for the spectrometer that will ultimately measure the LCLS electron pulse duration.

  3. The effect of gestational age and cervical length measurements in the prediction of spontaneous preterm birth in twin pregnancies : an individual patient level meta-analysis

    NARCIS (Netherlands)

    Kindinger, L M; Poon, L C; Cacciatore, S; MacIntyre, D A; Fox, N S; Schuit, E; Mol, B W; Liem, S; Lim, A C; Serra, V; Perales, A; Hermans, F; Darzi, A; Bennett, P; Nicolaides, K H; Teoh, T G

    2016-01-01

    OBJECTIVE: To assess the effect of gestational age (GA) and cervical length (CL) measurements at transvaginal ultrasound (TVUS) in the prediction of preterm birth in twin pregnancy. DESIGN: Individual patient data (IPD) meta-analysis. SETTING: International multicentre study. POPULATION:

  4. Systemic focal epileptogenesis

    Energy Technology Data Exchange (ETDEWEB)

    Remler, M.P.; Marcussen, W.H.

    1986-01-01

    Rats that receive radiation to 0.25 cc of one cerebral hemisphere are clinically and electroencephalographically normal until there is a breakdown of the blood-brain barrier (BBB) at 3 to 6 months postradiation. This BBB lesion can be detected by transient focal seizure activity produced by the BBB-excluded systemic convulsant bicuculline methiodide. In two rats the seizure activity induced by this one injection was self-sustaining. In seven of 15 other rats tested, the subsequent administration of repeated 2 mg/kg injections created a chronic focus that continued to spike with great frequency for 3 weeks or more without further administration of any convulsant. In three of eight other rats, implanted minipumps delivering 180 micrograms/h of bicuculline methiodide produced self-sustaining epileptic activity.

  5. Focal femoral condyle resurfacing.

    LENUS (Irish Health Repository)

    Brennan, S A

    2013-03-01

    Focal femoral inlay resurfacing has been developed for the treatment of full-thickness chondral defects of the knee. This technique involves implanting a defect-sized metallic or ceramic cap that is anchored to the subchondral bone through a screw or pin. The use of these experimental caps has been advocated in middle-aged patients who have failed non-operative methods or biological repair techniques and are deemed unsuitable for conventional arthroplasty because of their age. This paper outlines the implant design, surgical technique and biomechanical principles underlying their use. Outcomes following implantation in both animal and human studies are also reviewed. Cite this article: Bone Joint J 2013;95-B:301-4.

  6. Charging as a Focal Practice

    DEFF Research Database (Denmark)

    Bødker, Mads

    an example of how a mundance “device” turns focal once it is connected to a contextual infrastructure (the ‘wild’), and reflects on the applicability of the notion of focality. The guiding question is how the notion of ‘focal things and practices’ drawn from Borgmann might help us think about the (strained......This position paper reflects on Borgmann’s notion of ‘focal things’ and its applicability in the discourse about interaction with technologies in nature. Using the example of a combined cooking burner and thermoelectric 5W smartphone charger (a BioLite cook stove), this position paper gives...

  7. Focal surfaces of hyperbolic cylinders

    Science.gov (United States)

    Georgiev, Georgi Hristov; Pavlov, Milen Dimov

    2017-12-01

    Cylindrical surfaces have many applications in geometric modeling, architecture and other branches of engineering. In this paper, we describe two cylindrical surfaces associated to a given hyperbolic cylinder. The first one is a focal surface which is determined by reciprocal principle curvature of the hyperbolic cylinder. The second one is a generalized focal surface obtained by reciprocal mean curvature of the same hyperbolic cylinder. In particular, we show that each of these surfaces admits three different parametric representations. As consequence, it is proved that the focal and generalized focal surfaces of the hyperbolic cylinder are rational surfaces. An illustrative example is included.

  8. Variations of OCT measurements corrected for the magnification effect according to axial length and refractive error in children

    Directory of Open Access Journals (Sweden)

    Inmaculada Bueno-Gimeno

    2018-01-01

    Full Text Available Purpose: The aim of this paper was to examine the distribution of macular, retinal nerve fiber layer (RNFL thickness and optic disc parameters of myopic and hyperopic eyes in comparison with emmetropic control eyes and to investigate their variation according to axial length (AL and spherical equivalent (SE in healthy children. Methods: This study included 293 pairs of eyes of 293 children (145 boys and 148 girls, ranging in age from 6 to 17 years. Subjects were divided according to SE in control (emmetropia, 99 children, myopia (100 children and hyperopia (94 children groups and according to axial AL in 68 short (25.00mm, 36. Macular parameters, RNFL thickness and optic disc morphology were assessed by the CirrusTM HD-OCT. AL was measured using the IOL-Master system. Littmann’s formula was used for calculating the corrected AL-related ocular magnification. Results: Mean age (±SD was 10.84±3.05 years; mean (±SD SE was +0.14±0.51 D (range from −8.75 to +8.25 D and mean AL (±SD was 23.12±1.49. Average RNFL thickness, average macular thickness and macular volume decreased as AL and myopia increased. No correlations between AL/SE and optic disc parameters were found after correcting for magnification effect. Conclusions: AL and refractive error affect measurements of macular and RNFL thickness in healthy children. To make a correct interpretation of OCT measurements, ocular magnification effect should be taken into account by clinicians or OCT manufacturers.

  9. Inter-laboratory validation of the measurement of follicle stimulating hormone (FSH after various lengths of frozen storage

    Directory of Open Access Journals (Sweden)

    Behr Barry

    2010-11-01

    Full Text Available Abstract Background Serum follicle stimulating hormone (FSH levels are used clinically to evaluate infertility, pituitary and gonadal disorders. With increased frequency of research collaborations across institutions, it is essential that inter-laboratory validation is addressed. Methods An inter-laboratory validation of three commercial FSH immunoassays was performed with human serum samples of varying frozen storage length (2 batches of 15 samples each at -25 degree C. Percentage differences and Bland-Altman limits of agreement were calculated. Results The inter- and intra-laboratory consistency of FSH values with the same assay manufacturer was much higher after shorter-term storage (frozen for less than 11 months, mean percentage degradation less than 4% than after long-term storage (2-3 years, mean percentage degradation = 23%. Comparing assay results from different manufacturers, there was similar overall long term degradation as seen with the same manufacturer (-25%, however the degradation was greater when the original FSH was greater than 20 mIU/mL relative to less than 10 mIU/mL (p Conclusion The findings suggest that degradation of serum samples stored between 11 months and 2-3 years at -25 degrees C can lead to unstable FSH measurements. Inter-laboratory variability due to frozen storage time and manufacturer differences in assay results should be accounted for when designing and implementing research or clinical quality control activities involving serum FSH at multiple study sites.

  10. Focal midbrain tumors in children

    NARCIS (Netherlands)

    Vandertop, W. P.; Hoffman, H. J.; Drake, J. M.; Humphreys, R. P.; Rutka, J. T.; Amstrong, D. C.; Becker, L. E.

    1992-01-01

    The clinical and neuroradiological features of focal midbrain tumors in 12 children are described, and the results of their surgical management are presented. Patients with a focal midbrain tumor usually exhibit either symptoms and signs of raised intracranial pressure caused by an obstructive

  11. Comparison of left and right ventricular volume measurement using the Simpson's method and the area length method

    International Nuclear Information System (INIS)

    Hergan, Klaus; Schuster, Antonius; Fruehwald, Julia; Mair, Michael; Burger, Ralph; Toepker, Michael

    2008-01-01

    Purpose: To compare ventricular volume measurement using a volumetric approach in the three standard cardiac planes and ventricular volume estimation by a geometrical model, the Area-Length method (ALM). Materials and methods: Fifty-six healthy volunteers were examined (27 males, 29 females) on a 1.5 T MR-unit with ECG-triggered steady state free precision (SSFP) Cine-MR sequences and parallel image acquisition. Multiple slices in standardized planes including the short-axis view (sa), 4-chamber view (4ch), left and right 2-chamber views (2ch) were used to cover the whole heart. End-systolic and end-diastolic ventricular volumes (EDV, ESV), stroke volume (SV), and ejection fraction (EF) were calculated with Simpson's rule in all planes and with ALM in the 2ch and 4ch planes. Global function parameters measured in the sa plane were compared with those obtained in the other imaging planes. Results: A very good correlation is observed when comparing functional parameters calculated with Simpson's rule in all imaging planes: for instance, the mean EDV/ESV of the left and right ventricle of the female population group measured in sa, 4ch, and 2ch: left ventricle EDV/ESV 114.3/44.4, 120.9/46.5, and 117.7/45.3 ml; right ventricle EDV/ESV 106.6/46.0, 101.2/41.1, and 103.5/43.0 ml. Functional parameters of the left ventricle calculated with ALM in 2ch and 4ch correlate to parameters obtained in sa with Simpson's rule in the range of 5-10%: for instance, the EDV/ESV of the left ventricle of the male population group measured in the sa, 4ch, and 2ch: 160.3/63.5, 163.1/59.0, and 167.0/65.7 ml. Functional parameters of the right ventricle measured with ALM in 4ch are 40-50% lower and calculated in 2ch almost double as high as compared with the parameters obtained in sa with Simpson's rule: for instance, male right ventricular EDV/ESV measured in sa, 4ch, and 2ch: 153.4/68.1, 97.5/34.5, and 280.2/123.2 ml. The EF correlates for all imaging planes measured with the Simpson's rule

  12. Comparison of left and right ventricular volume measurement using the Simpson's method and the area length method

    Energy Technology Data Exchange (ETDEWEB)

    Hergan, Klaus [Department of Radiology, Paracelsus Medical University Salzburg (Austria)], E-mail: k.hergan@salk.at; Schuster, Antonius [Department of Radiology, LKH Feldkirch (Austria); Fruehwald, Julia [Department of Radiology, Medical University Vienna (Austria); Mair, Michael; Burger, Ralph; Toepker, Michael [Department of Radiology, LKH Feldkirch (Austria)

    2008-02-15

    Purpose: To compare ventricular volume measurement using a volumetric approach in the three standard cardiac planes and ventricular volume estimation by a geometrical model, the Area-Length method (ALM). Materials and methods: Fifty-six healthy volunteers were examined (27 males, 29 females) on a 1.5 T MR-unit with ECG-triggered steady state free precision (SSFP) Cine-MR sequences and parallel image acquisition. Multiple slices in standardized planes including the short-axis view (sa), 4-chamber view (4ch), left and right 2-chamber views (2ch) were used to cover the whole heart. End-systolic and end-diastolic ventricular volumes (EDV, ESV), stroke volume (SV), and ejection fraction (EF) were calculated with Simpson's rule in all planes and with ALM in the 2ch and 4ch planes. Global function parameters measured in the sa plane were compared with those obtained in the other imaging planes. Results: A very good correlation is observed when comparing functional parameters calculated with Simpson's rule in all imaging planes: for instance, the mean EDV/ESV of the left and right ventricle of the female population group measured in sa, 4ch, and 2ch: left ventricle EDV/ESV 114.3/44.4, 120.9/46.5, and 117.7/45.3 ml; right ventricle EDV/ESV 106.6/46.0, 101.2/41.1, and 103.5/43.0 ml. Functional parameters of the left ventricle calculated with ALM in 2ch and 4ch correlate to parameters obtained in sa with Simpson's rule in the range of 5-10%: for instance, the EDV/ESV of the left ventricle of the male population group measured in the sa, 4ch, and 2ch: 160.3/63.5, 163.1/59.0, and 167.0/65.7 ml. Functional parameters of the right ventricle measured with ALM in 4ch are 40-50% lower and calculated in 2ch almost double as high as compared with the parameters obtained in sa with Simpson's rule: for instance, male right ventricular EDV/ESV measured in sa, 4ch, and 2ch: 153.4/68.1, 97.5/34.5, and 280.2/123.2 ml. The EF correlates for all imaging planes measured

  13. ePAT: A simple method to tag adenylated RNA to measure poly(A)-tail length and other 3′ RACE applications

    OpenAIRE

    Jänicke, Amrei; Vancuylenberg, John; Boag, Peter R.; Traven, Ana; Beilharz, Traude H.

    2012-01-01

    The length of the poly(A)-tail that terminates most mRNA can serve as a readout of its metabolism. A long poly(A)-tail is generally associated with actively translating mRNA, whereas a short poly(A)-tail often indicates a translationally repressed state. Here, the authors present a simple new method to measure transcript-specific poly(A)-tail length using standard molecular biology reagents.

  14. Optical interconnections to focal plane arrays

    Energy Technology Data Exchange (ETDEWEB)

    Rienstra, J.L.; Hinckley, M.K.

    2000-11-01

    The authors have successfully demonstrated an optical data interconnection from the output of a focal plane array to the downstream data acquisition electronics. The demonstrated approach included a continuous wave laser beam directed at a multiple quantum well reflectance modulator connected to the focal plane array analog output. The output waveform from the optical interconnect was observed on an oscilloscope to be a replica of the input signal. They fed the output of the optical data link to the same data acquisition system used to characterize focal plane array performance. Measurements of the signal to noise ratio at the input and output of the optical interconnection showed that the signal to noise ratio was reduced by a factor of 10 or more. Analysis of the noise and link gain showed that the primary contributors to the additional noise were laser intensity noise and photodetector receiver noise. Subsequent efforts should be able to reduce these noise sources considerably and should result in substantially improved signal to noise performance. They also observed significant photocurrent generation in the reflectance modulator that imposes a current load on the focal plane array output amplifier. This current loading is an issue with the demonstrated approach because it tends to negate the power saving feature of the reflectance modulator interconnection concept.

  15. Assessment of hamstring muscle length in school-aged children using the sit-and-reach test and the inclinometer measure of hip joint angle.

    Science.gov (United States)

    Cornbleet, S L; Woolsey, N B

    1996-08-01

    The sit-and-reach test (SRT) is commonly used to assess flexibility of the spine and length of the hamstring muscles. The purposes of this study were (1) to describe hamstring muscle length as reflected by use of the SRT and the hip joint angle (HJA) in children, (2) to examine the correlation between SRT and HJA measurements, and (3) to examine gender differences for both measures. The participants were 410 school-aged children (211 girls, 199 boys). Each child performed the SRT. In the final position, the SRT score was obtained and the HJA was measured using an inclinometer placed over the sacrum. A mean SRT value of 24 cm and a mean HJA value of 81 degrees were obtained for all subjects. There was a strong correlation between the SRT and HJA measurements (r = .76). There was a difference between boys and girls for both measures. The results suggest differences in expectations for hamstring muscle length in boys and girls. Although scores for the SRT and HJA were correlated, we prefer to assess hamstring muscle length using HJA scores because these scores are not influenced by anthropometric factors or spinal mobility. The results of this study suggest that HJA measurements guide treatment more effectively than do SRT measurements.

  16. Determination of the length and position of the lower oesophageal sphincter (LOS) by correlation of external measurements with combined radiographic and manometric estimations in the cat

    International Nuclear Information System (INIS)

    Hashim, M.A.; Waterman, A.E.

    1992-01-01

    Fifty DSH cats were studied radiographically and a highly significant linear correlation was found between the length of the oesophagus measured to the diaphragmatic line on the radiographs and the externally measured distance from the lower jaw incisor teeth to the anterior border of the head of 10th rib. A subsequent manometric study utilizing this correlation in 40 cats suggests that the functional lower oesophageal sphincter (LOS) is situated almost at the level of the diaphragm in the cat. Significant differences were found between the length of the LOS in cats anaesthetized with ketamine compared to alphaxalone-alphadolone or xylazine-ketamine-atropine. The mean lengths of the LOS was 1.42 +/- 0.3 cm. The findings of this study indicate that external measurements can be used to position catheters for accurate oesophageal manometry in the cat

  17. Fundamental length and relativistic length

    International Nuclear Information System (INIS)

    Strel'tsov, V.N.

    1988-01-01

    It si noted that the introduction of fundamental length contradicts the conventional representations concerning the contraction of the longitudinal size of fast-moving objects. The use of the concept of relativistic length and the following ''elongation formula'' permits one to solve this problem

  18. Flame Length

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — Flame length was modeled using FlamMap, an interagency fire behavior mapping and analysis program that computes potential fire behavior characteristics. The tool...

  19. Accessible length scale of the in-plane structure in polarized neutron off-specular and grazing-incidence small-angle scattering measurements

    Science.gov (United States)

    Maruyama, R.; Bigault, T.; Wildes, A. R.; Dewhurst, C. D.; Saerbeck, T.; Honecker, D.; Yamazaki, D.; Soyama, K.; Courtois, P.

    2017-06-01

    Polarized neutron off-specular and grazing-incidence small-angle scattering measurements are useful methods to investigate the in-plane structure and its correlation of layered systems. Although these measurements give information on complementary and overlapping length scale, the different characteristics between them need to be taken into account when performed. In this study, the difference in the accessible length scale of the in-plane structure, which is one of the most important characteristics, was discussed using an Fe/Si multilayer together with simulations based on the distorted wave Born approximation.

  20. The computed cranial focal point

    NARCIS (Netherlands)

    Jong, G.A. de; Maal, T.J.J.; Delye, H.

    2015-01-01

    INTRODUCTION: Stereophotogrammetry is a radiation-free method for monitoring skull development after craniosynostosis repair. Lack of clear fixed reference points complicate longitudinal comparison of 3D photographs. Therefore we developed the 'computed cranial focal point' (CCFP). METHODS: The CCFP

  1. Diagnostic imaging in focal epilepsy

    International Nuclear Information System (INIS)

    Zlatareva, D.

    2013-01-01

    Focal epilepsies account for 60% of all seizure disorders worldwide. In this review the classic and new classification system of epileptic seizures and syndromes as well as genetic forms are discussed. Magnetic resonance (MR) is the technique of choice for diagnostic imaging in focal epilepsy because of its sensitivity and high tissue contrast. The review is focused on the lack of consensus of imaging protocols and reported findings in refractory epilepsy. The most frequently encountered MRI findings in epilepsy are reported and their imaging characteristics are depicted. Diagnosis of hippocampal sclerosis and malformations of cortical development as two major causes of refractory focal epilepsy is described in details. Some promising new techniques as positron emission tomography computed tomography (PET/CT) and MR and PET/CT fusion are briefly discussed. Also the relevance of adequate imaging in focal epilepsy, some practical points in imaging interpretation and differential diagnosis are highlighted. (author)

  2. Feasibility of repeated self-measurements of maximum step length and gait speed by community-dwelling older persons

    NARCIS (Netherlands)

    Bongers, K.T.; Schoon, Y.; Olde Rikkert, M.G.M.

    2016-01-01

    OBJECTIVES: Self-management of mobility and fall risk can be important in fall prevention; however, it remains unstudied. Therefore, the current study assessed whether community-dwelling older persons were able to repeatedly self-assess maximum step length (MSL) and gait speed (GS) in their own home

  3. Measurements on the influence of the length of the daily submergence time on the condition and appearence of mussels (

    NARCIS (Netherlands)

    Basal, M.

    1972-01-01

    Mussels (Mytilus edulis) living at different intertidal levels (viz. about 40, 10 and 0% of time exposed to the air) were compared as to length distribution, meat and shell weight, and linear dimensions. The long-exposed mussels were found to be on average smaller, to contain less meat, to

  4. Development and Psychometric Evaluation of a New Instrument for Measuring Sleep Length and Television and Computer Habits of Swedish School-Age Children

    Science.gov (United States)

    Garmy, Pernilla; Jakobsson, Ulf; Nyberg, Per

    2012-01-01

    The aim was to develop a new instrument for measuring length of sleep as well as television and computer habits in school-age children. A questionnaire was constructed for use when children visit the school health care unit. Three aspects of the validity of the questionnaire were examined: its face validity, content validity, and construct…

  5. Characterization of Small Focal Renal Lesions: Diagnostic Accuracy with Single-Phase Contrast-enhanced Dual-Energy CT with Material Attenuation Analysis Compared with Conventional Attenuation Measurements.

    Science.gov (United States)

    Marin, Daniele; Davis, Drew; Roy Choudhury, Kingshuk; Patel, Bhavik; Gupta, Rajan T; Mileto, Achille; Nelson, Rendon C

    2017-09-01

    Purpose To determine whether single-phase contrast material-enhanced dual-energy material attenuation analysis improves the characterization of small (1-4 cm) renal lesions compared with conventional attenuation measurements by using histopathologic analysis and follow-up imaging as the clinical reference standards. Materials and Methods In this retrospective, HIPAA-compliant, institutional review board-approved study, 136 consecutive patients (95 men and 41 women; mean age, 54 years) with 144 renal lesions (111 benign, 33 malignant) measuring 1-4 cm underwent single-energy unenhanced and contrast-enhanced dual-energy computed tomography (CT) of the abdomen. For each renal lesion, attenuation measurements were obtained; attenuation change of greater than or equal to 15 HU was considered evidence of enhancement. Dual-energy attenuation measurements were also obtained by using iodine-water, water-iodine, calcium-water, and water-calcium material basis pairs. Mean lesion attenuation values and material densities were compared between benign and malignant renal lesions by using the two-sample t test. Diagnostic accuracy of attenuation measurements and dual-energy material densities was assessed and validated by using 10-fold cross-validation to limit the effect of optimistic bias. Results By using cross-validated optimal thresholds at 100% sensitivity, iodine-water material attenuation images significantly improved specificity for differentiating between benign and malignant renal lesions compared with conventional enhancement measurements (93% [103 of 111]; 95% confidence interval: 86%, 97%; vs 81% [90 of 111]; 95% confidence interval: 73%, 88%) (P = .02). Sensitivity with iodine-water and calcium-water material attenuation images was also higher than that with conventional enhancement measurements, although the difference was not statistically significant. Conclusion Contrast-enhanced dual-energy CT with material attenuation analysis improves specificity for

  6. DESI focal plate mechanical integration and cooling

    Science.gov (United States)

    Lambert, A. R.; Besuner, R. W.; Claybaugh, T. M.; Silber, J. H.

    2016-08-01

    The Dark Energy Spectroscopic Instrument (DESI) is under construction to measure the expansion history of the Universe using the Baryon Acoustic Oscillation technique[1]. The spectra of 40 million galaxies over 14000 sq. deg will be measured during the life of the experiment. A new prime focus corrector for the KPNO Mayall telescope will deliver light to 5000 fiber optic positioners. The fibers in turn feed ten broad-band spectrographs. This paper describes the mechanical integration of the DESI focal plate and the thermal system design. The DESI focal plate is comprised of ten identical petal assemblies. Each petal contains 500 robotic fiber positioners. Each petal is a complete, self-contained unit, independent from the others, with integrated power supply, controllers, fiber routing, and cooling services. The major advantages of this scheme are: (1) supports installation and removal of complete petal assemblies in-situ, without disturbing the others, (2) component production, assembly stations, and test procedures are repeated and parallelizable, (3) a complete, full-scale prototype can be built and tested at an early date, (4) each production petal can be surveyed and tested as a complete unit, prior to integration, from the fiber tip at the focal surface to the fiber slit at the spectrograph. The ten petal assemblies will be installed in a single integration ring, which is mounted to the DESI corrector. The aluminum integration ring attaches to the steel corrector barrel via a flexured steel adapter, isolating the focal plate from differential thermal expansions. The plate scale will be kept stable by conductive cooling of the petal assembly. The guider and wavefront sensors (one per petal) will be convectively cooled by forced flow of air. Heat will be removed from the system at ten liquid-cooled cold plates, one per petal, operating at ambient temperature. The entire focal plate structure is enclosed in an insulating shroud, which serves as a thermal barrier

  7. Development and reliability of the Achilles Tendon Length Measure and comparison with the Achilles Tendon Resting Angle on patients with an Achilles tendon rupture

    DEFF Research Database (Denmark)

    Hansen, Maria Swennergren; Barfod, Kristoffer Weisskirchner; Kristensen, Morten Tange

    2017-01-01

    BACKGROUND: There is a need for a valid, reliable, and easily applicable clinical measure of the length of the Achilles tendon (AT) after rupture. This study examines the reliability of a new ruler based measurement, the Achilles Tendon Length Measure (ATLM) in comparison with the goniometer......-based Achilles Tendon Resting Angle (ATRA). METHODS: Measurements were performed by two independent physiotherapists eight weeks after AT rupture on 28 patients treated non-operatively. RESULTS: The mean (SD) injured ATLM was 56.5 (2.3)cm, ICC2.1 0.91(CI [0.72-0.97]), SEM 0.7cm (SEM% 1.2), MDC 1.9cm (MDC% 3...

  8. Upright MRI measurement of mechanical axis and frontal plane alignment as a new technique: a comparative study with weight bearing full length radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Liodakis, Emmanouil; Kenawey, Mohamed; Doxastaki, Iosifina; Krettek, Christian; Haasper, Carl; Hankemeier, Stefan [Medical School Hannover, Department of Trauma Surgery, Hannover (Germany)

    2011-07-15

    The purpose of this prospective study was to investigate the practicality, accuracy, and reliability of upright MR imaging as a new radiation-free technique for the measurement of mechanical axis. We used upright MRI in 15 consecutive patients (30 limbs, 44.7 {+-} 20.6 years old) to measure mechanical axis deviation (MAD), hip-knee-ankle (HKA) angle, leg length, and all remaining angles of the frontal plane alignment according to Paley (mLPFA, mLDTA, mMPTA, mLDTA, JLCA). The measurements were compared to weight bearing full length radiographs, which are considered to be the standard of reference for planning corrective surgery. FDA-approved medical planning software (MediCAD) was used for the above measurements. Intra- and inter-observer reproducibility using mean absolute differences was also calculated for both methods. The correlation coefficient between angles determined with upright MRI and weight bearing full length radiographs was high for mLPFA, mLDTA, mMPTA, mLDTA, and the HKA angle (r > 0.70). Mean interobserver and intraobserver agreements for upright MRI were also very high (r > 0.89). The leg length and the MAD were significantly underestimated by MRI (-3.2 {+-} 2.2 cm, p < 0.001 and -6.2 {+-} 4.4 mm, p = 0.006, respectively). With the exception of underestimation of leg length and MAD, upright MR imaging measurements of the frontal plane angles are precise and produce reliable, reproducible results. (orig.)

  9. Fundamental length

    International Nuclear Information System (INIS)

    Pradhan, T.

    1975-01-01

    The concept of fundamental length was first put forward by Heisenberg from purely dimensional reasons. From a study of the observed masses of the elementary particles known at that time, it is sumrised that this length should be of the order of magnitude 1 approximately 10 -13 cm. It was Heisenberg's belief that introduction of such a fundamental length would eliminate the divergence difficulties from relativistic quantum field theory by cutting off the high energy regions of the 'proper fields'. Since the divergence difficulties arise primarily due to infinite number of degrees of freedom, one simple remedy would be the introduction of a principle that limits these degrees of freedom by removing the effectiveness of the waves with a frequency exceeding a certain limit without destroying the relativistic invariance of the theory. The principle can be stated as follows: It is in principle impossible to invent an experiment of any kind that will permit a distintion between the positions of two particles at rest, the distance between which is below a certain limit. A more elegant way of introducing fundamental length into quantum theory is through commutation relations between two position operators. In quantum field theory such as quantum electrodynamics, it can be introduced through the commutation relation between two interpolating photon fields (vector potentials). (K.B.)

  10. Body mass index, Bishop score, and sonographic measurement of the cervical length as predictors of successful labor induction in twin gestations.

    Science.gov (United States)

    Park, Kyo-Hoon; Hong, Joon-Seok; Kang, Woong-Sun; Shin, Dong-Myung; Kim, Shi-Nae

    2009-01-01

    To evaluate the predictive value of body mass index (BMI), Bishop score, and sonographic measurement of cervical length for predicting successful labor induction (defined as an ability to achieve the active phase of labor corresponding to a cervical dilatation of > or =4 cm within 12 h of initiating oxytocin) in near-term twin gestations. This prospective, observational study enrolled 72 consecutive women with twin gestations at >36.0 weeks' gestation who were scheduled for induction of labor. Transvaginal ultrasound for measurement of the cervical length was performed and the Bishop score was determined by digital examination. The BMI was calculated based on the weight and height at the time of induction. Labor induction was successful in 63% (45/72) of women. The mean BMI was significantly lower in women who had successfully induced labor, but no significant differences existed with respect to the mean cervical length, median Bishop score, proportion of parous and nulliparous women, and the mean total birth weight of the twin pairs between the two patient groups. Multiple logistic regression demonstrated that only BMI provided a significant contribution in predicting successful labor induction. BMI independently predicted the success of labor induction in twin gestations but the sonographic measurement of the cervical length and Bishop score had poor predictive values for successful induction.

  11. Effects of different storage and measuring methods on larval length values for the blow flies (Diptera: Calliphoridae) Lucilia sericata and Calliphora vicina.

    Science.gov (United States)

    Bugelli, Valentina; Campobasso, Carlo Pietro; Verhoff, Marcel A; Amendt, Jens

    2017-05-01

    In forensic entomology, the methods of sampling, killing, and storing entomological samples can affect larval age estimation, and, hence, the estimation of the minimum post-mortem interval. In the existing manuals, there is a certain amount of heterogeneity regarding methods and the recommendations for best practice in forensic entomology are insufficiently validated. This study evaluated three different length-measurement methods for larval stages and examined the influence of different killing and storing methods on the larval length of two forensically important blow flies, Lucilia sericata and Calliphora vicina. The three different measuring methods were a) a ruler with a 0.1mm scale, b) a geometrical micrometer, and c) a computer-aided stereomicroscope. They were used to measure the length of L 1 -L 3 C. vicina larvae and detect no significant differences. This supports the view that a simple tool like a geometrical micrometer can produce reliable results in forensic entomology. Newly hatched larvae of L. sericata and C. vicina were killed with hot water (HW) and divided into two equal subsamples. Lengths of all larvae were measured immediately after killing, then every 24h until day 4, and once more after 7days of storage in ≥70%-ethanol. L. sericata larvae only showed significant changes in length in the HW group stored at room temperature. After 4 and 7days of storage, these 24-h- and 72-h-old larvae showed a significant decrease in length compared with those in a fridge at 6°C. This decrease can, however, be considered a negligible natural variation without forensically relevant consequences for larval age estimation of L. sericata samples. For C. vicina, an increase in length was observed over time. This was significant only for younger larvae (24-48h old) stored in 70%-ethanol. This variance in length can lead to a wrong estimation of age; however, only for larvae stored in 70%-ethanol, not for those stored in 96%-ethanol. We examined the influence of

  12. First observation of $\\pi^{-}K^+$ and $\\pi^{+}K^-$ atoms, their lifetime measurement and $\\pi K$ scattering lengths evaluation

    CERN Document Server

    Afanasyev, Leonid

    2016-01-01

    The Low Energy QCD allows to calculate the ππ and π K scattering lengths with high precision. There are accurate relations between these scattering lengths and π + π − , π − K + , π + K − atoms lifetimes. The experiment on the first observation of π − K + and π + K − atoms is described. The atoms were generated in Nickel and Platinum targets hit by the PS CERN proton beam with momentum of 24 GeV/ c . Moving in the target, part of atoms break up producing characteristic π K pairs (atomic pairs) with small relative momentum Q in their c.m.s. In the experiment, we detected n A = 349 ± 62 (5.6 standard deviations) π − K + and π + K − atomic pairs. The main part of π K pairs are produced in free state. The majority of such particles are generated directly or from short-lived sources as ρ , ω and similar resonances. The electromagnetic interactions in the final state create Coulomb pairs with a known sharp dependence on Q . This effect allows to evaluate the number of these Coulomb pai...

  13. [DWI MAGNETIC RESONANCE IN CHARACTERIZATION OF FOCAL LIVER LESIONS].

    Science.gov (United States)

    Jahić, E; Sofić, A; Husić-Selimović, A

    2016-09-01

    The aim of this study was to examine the possibilities of measuring ADC/DWI values with the ROI method for precise differentiation of focal liver lesions from normal liver parenchyma. The study included 100 liver lesions sized ≥1 cm, previously detected in patients by ultrasound and computed tomography. It is done by measuring the diffusion coefficient ADC folder (MRI 3T), setting the ROI on the periphery of hepatic lesions, on the liver parenchyma around the focal hepatic lesions and on liver parenchyma that is distant to hepatic lesions. In our study, difference between the average ADC value of focal liver lesions (1.24 x10(-3) mm(2)/s) and normal liver parenchyma around focal liver lesions (1.001x10(-3) mm(2)/s) was statistically confirmed. There was statistically proven difference in the average ADC values between normal liver parenchyma around focal lesions and liver parenchyma located distant from focal lesions of (1.003x10-3 mm2/s). Wilcoxon rank test yielded differences in the average (median) ADC values between total lesions in patients and liver parenchyma directly around focal lesions (p<0.0005). Wilcoxon rank test showed no differences in the average (median) ADC between liver parenchyma directly around focal lesions and distant of focal hepatic lesions (p<0.0005). The results obtained for each focal liver lesion were compared with histopathology findings obtained by puncture or surgery, and for cystic lesions radiological follow up was sufficient. For all liver lesions, the resulting overall DWI/ADC sensitivity was 92% and specificity 77%. Kendall’s tau-b coefficient of concordance showed a statistically significant correlation between our DWI diagnosis and histopathology verification for all liver lesions (p<0.0005). He mangiomas and cysts showed greatest difference in ADC values as compared with healthy liver. ADC values of hepatocellular carcinoma (HCC) and the surrounding normal liver parenchyma were not statistically different, which can be

  14. Measurement of Dead Space Fraction Upon ICU Admission Predicts Length of Stay and Clinical Outcomes Following Bidirectional Cavopulmonary Anastomosis.

    Science.gov (United States)

    Cigarroa, Claire L; van den Bosch, Sarah J; Tang, Xiaoqi; Gauvreau, Kimberlee; Baird, Christopher W; DiNardo, James A; Kheir, John Nagi

    2018-01-01

    saturation were linearly associated with prolonged ICU length of stay, hospital length of stay, duration of mechanical ventilation, and duration of thoracic drainage (p space fraction in excess of 0.28 or arterial oxyhemoglobin saturation less than 78% upon ICU admission indicates an increased likelihood of requiring intervention prior to hospital discharge. Increasing alveolar dead space fraction and decreasing arterial oxyhemoglobin saturation are associated with increased lengths of stay.

  15. Effects of correlations between particle longitudinal positions and transverse plane on bunch length measurement: a case study on GBS electron LINAC at ELI-NP

    Science.gov (United States)

    Sabato, L.; Arpaia, P.; Cianchi, A.; Liccardo, A.; Mostacci, A.; Palumbo, L.; Variola, A.

    2018-02-01

    In high-brightness LINear ACcelerators (LINACs), electron bunch length can be measured indirectly by a radio frequency deflector (RFD). In this paper, the accuracy loss arising from non-negligible correlations between particle longitudinal positions and the transverse plane (in particular the vertical one) at RFD entrance is analytically assessed. Theoretical predictions are compared with simulation results, obtained by means of ELEctron Generation ANd Tracking (ELEGANT) code, in the case study of the gamma beam system (GBS) at the extreme light infrastructure—nuclear physics (ELI-NP). In particular, the relative error affecting the bunch length measurement, for bunches characterized by both energy chirp and fixed correlation coefficients between longitudinal particle positions and the vertical plane, is reported. Moreover, the relative error versus the correlation coefficients is shown for fixed RFD phase 0 rad and π rad. The relationship between relative error and correlations factors can help the decision of using the bunch length measurement technique with one or two vertical spot size measurements in order to cancel the correlations contribution. In the case of the GBS electron LINAC, the misalignment of one of the quadrupoles before the RFD between  ‑2 mm and 2 mm leads to a relative error less than 5%. The misalignment of the first C-band accelerating section between  ‑2 mm and 2 mm could lead to a relative error up to 10%.

  16. Educational attainment but not measures of current socioeconomic circumstances are associated with leukocyte telomere length in healthy older men and women.

    Science.gov (United States)

    Steptoe, Andrew; Hamer, Mark; Butcher, Lee; Lin, Jue; Brydon, Lena; Kivimäki, Mika; Marmot, Michael; Blackburn, Elizabeth; Erusalimsky, Jorge D

    2011-10-01

    Low socioeconomic status (SES) may be associated with accelerated biological aging, but findings relating SES with telomere length have been inconsistent. We tested the hypotheses that shorter telomere length and telomerase activity would be related more robustly to education, an early life indicator of socioeconomic position, than to current indicators of socioeconomic circumstances. Healthy men and women aged 53-76 years from the Whitehall II epidemiological cohort provided blood samples from which telomere length was assessed in 448 and telomerase activity in 416. Educational attainment was classified into four levels, while household income and grade of employment were measured as indicators of current socioeconomic circumstances. Age, gender, blood pressure, glycated hemoglobin, high density lipoprotein cholesterol, smoking, body mass index and physical activity were included as covariates. We found that lower educational attainment was associated with shorter telomere length after controlling statistically for biological and behavioral covariates. Neither household income nor employment grade was related to telomere length. The association between telomere length and education remained significant after adjusting for current socioeconomic circumstances. In men, highest levels of telomerase activity were found in the lowest education group. We conclude that low SES defined in terms of education but not current socioeconomic circumstances is associated with shortened telomeres. Low educational attainment may be an indicator of long-term SES trajectories, and be associated with accumulated allostatic load resulting in telomere shortening. Education may also promote problem-solving skills leading to reduced biological stress responsivity, with favorable consequences for biological aging. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. MEASUREMENT OF LOW ENERGY DETECTION EFFICIENCY OF A PLASTIC SCINTILLATOR: IMPLICATIONS ON THE LOWER ENERGY LIMIT AND SENSITIVITY OF A HARD X-RAY FOCAL PLANE COMPTON POLARIMETER

    International Nuclear Information System (INIS)

    Chattopadhyay, T.; Vadawale, S. V.; Shanmugam, M.; Goyal, S. K.

    2014-01-01

    The polarization measurements in X-rays offer a unique opportunity for the study of physical processes under the extreme conditions prevalent at compact X-ray sources, including gravitation, magnetic field, and temperature. Unfortunately, there has been no real progress in observational X-ray polarimetry thus far. Although photoelectron tracking-based X-ray polarimeters provide realistic prospects of polarimetric observations, they are effective in the soft X-rays only. With the advent of hard X-ray optics, it has become possible to design sensitive X-ray polarimeters in hard X-rays based on Compton scattering. An important point that should be carefully considered for the Compton polarimeters is the lower energy threshold of the active scatterer, which typically consists of a plastic scintillator due to its lowest effective atomic number. Therefore, an accurate understanding of the plastic scintillators energy threshold is essential to make a realistic estimate of the energy range and sensitivity of any Compton polarimeter. In this context, we set up an experiment to investigate the plastic scintillators behavior for very low energy deposition events. The experiment involves the detection of Compton scattered photons from a long, thin, plastic scintillator (a similar configuration as the eventual Compton polarimeter) by a high resolution CdTe detector at different scattering angles. We find that it is possible to detect energy deposition well below 1 keV, though with decreasing efficiency. We present detailed semianalytical modeling of our experimental setup and discuss the results in the context of the energy range and sensitivity of the Compton polarimeter involving plastic scintillators

  18. Focal lesions of the patella

    Energy Technology Data Exchange (ETDEWEB)

    Hedayati, B. [Royal national Orthopaedic Hospital Stanmore, Brockley Hill Stanmore, Department of Radiology, Middlesex (United Kingdom); Lewisham Hospital NHS Trust, Department of Radiology, London (United Kingdom); Saifuddin, A. [Royal national Orthopaedic Hospital Stanmore, Brockley Hill Stanmore, Department of Radiology, Middlesex (United Kingdom)

    2009-08-15

    Focal lesions of the patella may be identified during the investigation of anterior knee pain or as an incidental finding on radiological images. This pictorial review describes the radiographic appearances of a wide range of conditions that have been seen in this sesamoid bone. Where appropriate, computed tomography and magnetic resonance features have been included. (orig.)

  19. Focal therapy in prostate cancer

    NARCIS (Netherlands)

    van den Bos, W.

    2016-01-01

    Interesting developments took place in the treatment of prostate cancer including focal therapy for less aggressive organ-confined prostate cancer. Fortunately, curative treatment is often still an option for patients suffering from the lower staged tumors. In carefully selected patients, the

  20. Prediction of preterm birth in multiple pregnancies: development of a multivariable model including cervical length measurement at 16 to 21 weeks' gestation.

    Science.gov (United States)

    van de Mheen, Lidewij; Schuit, Ewoud; Lim, Arianne C; Porath, Martina M; Papatsonis, Dimitri; Erwich, Jan J; van Eyck, Jim; van Oirschot, Charlotte M; Hummel, Piet; Duvekot, Johannes J; Hasaart, Tom H M; Groenwold, Rolf H H; Moons, Karl G M; de Groot, Christianne J M; Bruinse, Hein W; van Pampus, Maria G; Mol, Ben W J

    2014-04-01

    To develop a multivariable prognostic model for the risk of preterm delivery in women with multiple pregnancy that includes cervical length measurement at 16 to 21 weeks' gestation and other variables. We used data from a previous randomized trial. We assessed the association between maternal and pregnancy characteristics including cervical length measurement at 16 to 21 weeks' gestation and time to delivery using multivariable Cox regression modelling. Performance of the final model was assessed for the outcomes of preterm and very preterm delivery using calibration and discrimination measures. We studied 507 women, of whom 270 (53%) delivered models for preterm and very preterm delivery had a c-index of 0.68 (95% CI 0.63 to 0.72) and 0.68 (95% CI 0.62 to 0.75), respectively, and showed good calibration. In women with a multiple pregnancy, the risk of preterm delivery can be assessed with a multivariable model incorporating cervical length and other predictors.

  1. Vertebrae length and ultra-structure measurements of collagen fibrils and mineral content in the vertebrae of lordotic gilthead seabreams (Sparus aurata).

    Science.gov (United States)

    Berillis, Panagiotis; Panagiotopoulos, Nikolaos; Boursiaki, Vaia; Karapanagiotidis, Ioannis T; Mente, Eleni

    2015-08-01

    Skeletal deformities of gilthead seabream (Sparus aurata) are a major factor affecting the production cost, the external morphology and survival and growth of the fish. Adult individuals of S. aurata were collected from a commercial fish farm in Greece and were divided into two groups: one with the presence of lordosis, a skeletal deformity, and one without any skeletal deformity. Fishes were X-rayed, and cervical, abdominal and caudal vertebrae lengths were measured. Vertebrae were taken from the site of the vertebral column where lordosis occurred. One part was decalcified and prepared for collagen examination with transmission electron microscopy, and the rest were incinerated, and the Ca and P contents were measured. The stoichiometries of the samples were obtained by EDS (Energy Dispersive Spectroscopy). The same procedure was followed for fish without skeletal deformities (vertebrae were taken from the middle region of the vertebral column). The decalcified vertebrae parts were examined with TEM, collagen micrographs were taken and the fibrils' periods and diameters were measured. There were no significant differences for both Ca and P or the collagen fibrils' periods between the two fish groups. The mean lengths of the cervical, abdominal and caudal vertebrae where lordosis occurred were similar to the lengths of the respective regions of the individuals without the skeletal deformity. The TEM examination showed a significantly smaller mean vertebrae collagen fibril diameter from the fishes with lordosis compared with those from the controls, revealing the significance of collagen to bone structure. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Is measurement of cervical length an accurate predictive tool in women with a history of preterm delivery who present with threatened preterm labor?

    Science.gov (United States)

    Melamed, N; Hiersch, L; Meizner, I; Bardin, R; Wiznitzer, A; Yogev, Y

    2014-12-01

    To determine whether sonographically measured cervical length is an effective predictive tool in women with threatened preterm labor and a history of past spontaneous preterm delivery. This was a retrospective cohort study of all women with singleton pregnancies who presented with preterm labor at less than 34 + 0 weeks' gestation and underwent sonographic measurement of cervical length in a tertiary medical center between 2007 and 2012. The accuracy of cervical length in predicting preterm delivery was compared between women with and those without a history of spontaneous preterm delivery. Women with risk factors for preterm delivery other than a history of preterm delivery were excluded from both groups. Overall, 1023 women who presented with preterm labor met the study criteria, of whom 136 (13.3%) had a history of preterm delivery (past-PTD group) and 887 (86.7%) had no risk factors for preterm delivery (low-risk group). The rate of preterm delivery was significantly higher for women with a history of preterm delivery (36.8% vs 22.5%; P delivery interval in low-risk women (r = 0.32, P delivery (r = 0.07, P = 0.4). On multivariable analysis, cervical length was independently associated with the risk of preterm delivery for women in the low-risk group but not for women with a history of previous preterm delivery. For women with previous preterm delivery who presented with threatened preterm labor, cervical length failed to distinguish between those who did and those who did not deliver prematurely (area under the receiver-operating characteristics curve range, 0.475-0.506). When using standardized thresholds, the sensitivity and specificity of cervical length for the prediction of preterm delivery were significantly lower in women with previous preterm delivery than in women with no risk factors for preterm delivery. Cervical length appears to be of limited value in the prediction of preterm delivery among women with threatened preterm labor

  3. Comparison of four measures in reducing length of stay in burns: An Asian centre's evolved multimodal burns protocol.

    Science.gov (United States)

    Chong, Si Jack; Kok, Yee Onn; Choke, Abby; Tan, Esther W X; Tan, Kok Chai; Tan, Bien-Keem

    2017-09-01

    Multidisciplinary burns care is constantly evolving to improve outcomes given the numerous modalities available. We examine the use of Biobrane, micrografting, early renal replacement therapy and a strict target time of surgery within 24h of burns on improving outcomes of length of stay, duration of surgery, mean number of surgeries and number of positive tissue cultures in a tertiary burns centre. A post-implementation prospective cohort of inpatient burns patients from 2014 to 2015 (n=137) was compared against a similar pre-implementation cohort from 2013 to 2014 (n=93) using REDCAP, an electronic database. There was no statistically significant difference for comorbidities, age and percentage (%) TBSA between the new protocol and control groups. The protocol group had shorter mean time to surgery (23.5-38.5h) (pmicrograft/allograft, early CRRT and surgery within 24h were successfully introduced. These are useful adjuncts in the armamentarium to be considered for any burns centre. Copyright © 2017. Published by Elsevier Ltd.

  4. Telomere length and depression

    DEFF Research Database (Denmark)

    Wium-Andersen, Marie Kim; Ørsted, David Dynnes; Rode, Line

    2017-01-01

    BACKGROUND: Depression has been cross-sectionally associated with short telomeres as a measure of biological age. However, the direction and nature of the association is currently unclear. AIMS: We examined whether short telomere length is associated with depression cross-sectionally as well...... as prospectively and genetically. METHOD: Telomere length and three polymorphisms, TERT, TERC and OBFC1, were measured in 67 306 individuals aged 20-100 years from the Danish general population and associated with register-based attendance at hospital for depression and purchase of antidepressant medication....... RESULTS: Attendance at hospital for depression was associated with short telomere length cross-sectionally, but not prospectively. Further, purchase of antidepressant medication was not associated with short telomere length cross-sectionally or prospectively. Mean follow-up was 7.6 years (range 0...

  5. Measurement of muscle length-related electromyography activity of the hip flexor muscles to determine individual muscle contributions to the hip flexion torque.

    Science.gov (United States)

    Jiroumaru, Takumi; Kurihara, Toshiyuki; Isaka, Tadao

    2014-01-01

    This study aimed to investigate muscle length-related electromyography (EMG) of the iliopsoas (IL) and other hip flexor muscles to determine individual muscle contributions to the hip flexion torque. Ten healthy sedentary young men participated in the EMG experiment. A subgroup of six subjects underwent a magnetic resonance imaging (MRI) measurement to confirm the region of the skin over the IL. Surface EMG signals were sampled from the IL, rectus femoris (RF), sartorius (SA), and tensor fasciae latae (TFL) using an active electrode. The subjects performed maximum voluntary isometric hip flexion with the right hip joint set at -10°, 0°, 30°, and 60°. The root mean square (RMS) value for the TFL at 30° (0.81 ± 0.19, p muscle length changes were significantly correlated in the IL (r =0.39, p muscles.

  6. Cervical length measurement in nulliparous women at term by ultrasound & its relationship to spontaneous onset of labour

    Directory of Open Access Journals (Sweden)

    Joydev Mukherji

    2017-01-01

    Interpretation & conclusions: Inter-individual variations in CL and in CL changes were large. Thus, it was not practical to predict spontaneous onset of labour by sonographic CL measurement near term. Post-dated pregnancy may be predicted with limited success. Further studies should explore other parameters, in addition to CL.

  7. Inverse-designed stretchable metalens with tunable focal distance

    Science.gov (United States)

    Callewaert, Francois; Velev, Vesselin; Jiang, Shizhou; Sahakian, Alan Varteres; Kumar, Prem; Aydin, Koray

    2018-02-01

    In this paper, we present an inverse-designed 3D-printed all-dielectric stretchable millimeter wave metalens with a tunable focal distance. A computational inverse-design method is used to design a flat metalens made of disconnected polymer building blocks with complex shapes, as opposed to conventional monolithic lenses. The proposed metalens provides better performance than a conventional Fresnel lens, using lesser amount of material and enabling larger focal distance tunability. The metalens is fabricated using a commercial 3D-printer and attached to a stretchable platform. Measurements and simulations show that the focal distance can be tuned by a factor of 4 with a stretching factor of only 75%, a nearly diffraction-limited focal spot, and with a 70% relative focusing efficiency, defined as the ratio between power focused in the focal spot and power going through the focal plane. The proposed platform can be extended for design and fabrication of multiple electromagnetic devices working from visible to microwave radiation depending on scaling of the devices.

  8. Focal hyperhidrosis: diagnosis and management

    Science.gov (United States)

    Haider, Aamir; Solish, Nowell

    2005-01-01

    HYPERHIDROSIS, A CONDITION CHARACTERIZED by excessive sweating, can be generalized or focal. Generalized hyperhidrosis involves the entire body and is usually part of an underlying condition, most often an infectious, endocrine or neurologic disorder. Focal hyperhidrosis is idiopathic, occurring in otherwise healthy people. It affects 1 or more body areas, most often the palms, armpits, soles or face. Almost 3% of the general population, largely people aged between 25 and 64 years, experience hyperhidrosis. The condition carries a substantial psychological and social burden, since it interferes with daily activities. However, patients rarely seek a physician's help because many are unaware that they have a treatable medical disorder. Early detection and management of hyperhidrosis can significantly improve a patient's quality of life. There are various topical, systemic, surgical and nonsurgical treatments available with efficacy rates greater than 90%–95%. PMID:15632408

  9. Design and validation of a 3D virtual reality desktop system for sonographic length and volume measurements in early pregnancy evaluation.

    Science.gov (United States)

    Baken, Leonie; van Gruting, Isabelle M A; Steegers, Eric A P; van der Spek, Peter J; Exalto, Niek; Koning, Anton H J

    2015-03-01

    To design and validate a desktop virtual reality (VR) system, for presentation and assessment of volumetric data, based on commercially off-the-shelf hardware as an alternative to a fully immersive CAVE-like I-Space VR system. We designed a desktop VR system, using a three-dimensional (3D) monitor and a six degrees-of-freedom tracking system. A personal computer uses the V-Scope (Erasmus MC, Rotterdam, The Netherlands) volume-rendering application, developed for the I-Space, to create a hologram of volumetric data. Inter- and intraobserver reliability for crown-rump length and embryonic volume measurements are investigated using Bland-Altman plots and intraclass correlation coefficients. Time required for the measurements was recorded. Comparing the I-Space and the desktop VR system, the mean difference for crown-rump length is -0.34% (limits of agreement -2.58-1.89, ±2.24%) and for embryonic volume -0.92% (limits of agreement -6.97-5.13, ±6.05%). Intra- and interobserver intraclass correlation coefficients of the desktop VR system were all >0.99. Measurement times were longer on the desktop VR system compared with the I-Space, but the differences were not statistically significant. A user-friendly desktop VR system can be put together using commercially off-the-shelf hardware at an acceptable price. This system provides a valid and reliable method for embryonic length and volume measurements and can be used in clinical practice. © 2014 Wiley Periodicals, Inc.

  10. Grupo Focal em Pesquisas Sociais

    Directory of Open Access Journals (Sweden)

    Maria Lúcia Silva Servo

    2012-10-01

    Full Text Available Este artigo tem como objetivo discutir a técnica de grupo focal em pesquisas sociais. Apresenta-se as concepções sobre grupo focal. Traz-se os postulados de Pichon-Rivière sobre grupo operativo, os instrumentos de planificação, os vetores do campo grupal para nortear a dinâmica e a observação do campo grupal, bem como a organização, a operacionalização e a análise dos dados das sessões de grupo focal. Através desta técnica de coleta de dados em pesquisas sociais, é possível a construção do ECRO grupal sobre a tarefa proposta pelo pesquisador; e, a elaboração do projeto grupal a partir da aceitação ativa dos sujeitos sociais participantes da investigação.

  11. Focal midbrain tumors in children.

    Science.gov (United States)

    Vandertop, W P; Hoffman, H J; Drake, J M; Humphreys, R P; Rutka, J T; Amstrong, D C; Becker, L E

    1992-08-01

    The clinical and neuroradiological features of focal midbrain tumors in 12 children are described, and the results of their surgical management are presented. Patients with a focal midbrain tumor usually exhibit either symptoms and signs of raised intracranial pressure caused by an obstructive hydrocephalus (50%) or symptoms and signs caused by pressure on the tegmentum and cerebral peduncles. The lesions are confined to the tectal plate or tegmentum with possible extension upward to the thalamus and downward to the pons, displacing but not invading these structures. The edges of the tumor are well defined, and the large majority have a solid consistency with intense regular enhancement after intravenous contrast. Radical resection is hardly ever feasible in brain stem tumors, but in this series, significant reduction of the tumor mass was obtained in 75% of the patients, with no surgical mortality and minimal surgical morbidity and with the majority of patients showing clinical improvement postoperatively. All tumors were nonpilocytic, low-grade astrocytomas. Six patients received adjunctive radiotherapy. The mean follow-up period is 2.5 years, and all patients are alive and doing well. We conclude that focal midbrain tumors in children appear to be a distinct subgroup of brain stem tumors and are very amenable to surgical resection with an excellent long-term prognosis.

  12. Sub-recoil cooling up to nano-Kelvin. Direct measurement of spatial coherency length. New tests for Levy statistics

    International Nuclear Information System (INIS)

    Saubamea, B.

    1998-12-01

    This thesis presents a new method to measure the temperature of ultracold atoms from the spatial autocorrelation function of the atomic wave-packets. We thus determine the temperature of metastable helium-4 atoms cooled by velocity selective dark resonance, a method known to cool the atoms below the temperature related to the emission or the absorption of a single photon by an atom at rest, namely the recoil temperature. This cooling mechanism prepares each atom in a coherent superposition of two wave-packets with opposite mean momenta, which are initially superimposed and then drift apart. By measuring the temporal decay of their overlap, we have access to the Fourier transform of the momentum distribution of the atoms. Using this method, we can measure temperatures as low as 5 nK, 800 times as small as the recoil temperature. Moreover we study in detail the exact shape of the momentum distribution and compare the experimental results with two different theoretical approaches: a quantum Monte Carlo simulation and an analytical model based on Levy statistics. We compare the calculated line shape with the one deduced from simulations, and each theoretical model with experimental data. A very good agreement is found with each approach. We thus demonstrate the validity of the statistical model of sub-recoil cooling and give the first experimental evidence of some of its characteristics: the absence of steady-state, the self-similarity and the non Lorentzian shape of the momentum distribution of the cooled atoms. All these aspects are related to the non ergodicity of sub-recoil cooling. (author)

  13. ePAT: A simple method to tag adenylated RNA to measure poly(A)-tail length and other 3′ RACE applications

    Science.gov (United States)

    Jänicke, Amrei; Vancuylenberg, John; Boag, Peter R.; Traven, Ana; Beilharz, Traude H.

    2012-01-01

    The addition of a poly(A)-tail to the 3′ termini of RNA molecules influences stability, nuclear export, and efficiency of translation. In the cytoplasm, dynamic changes in the length of the poly(A)-tail have long been recognized as reflective of the switch between translational silence and activation. Thus, measurement of the poly(A)-tail associated with any given mRNA at steady-state can serve as a surrogate readout of its translation-state. Here, we describe a simple new method to 3′-tag adenylated RNA in total RNA samples using the intrinsic property of Escherichia coli DNA polymerase I to extend an RNA primer using a DNA template. This tag can serve as an anchor for cDNA synthesis and subsequent gene-specific PCR to assess poly(A)-tail length. We call this method extension Poly(A) Test (ePAT). The ePAT approach is as efficient as traditional Ligation-Mediated Poly(A) Test (LM-PAT) assays, avoids problems of internal priming associated with oligo-dT-based methods, and allows for the accurate analysis of both the poly(A)-tail length and alternate 3′ UTR usage in 3′ RACE applications. PMID:22543866

  14. The Sentinel 4 focal plane subsystem

    Science.gov (United States)

    Hohn, Rüdiger; Skegg, Michael P.; Hermsen, Markus; Hinger, Jürgen; Williges, Christian; Reulke, Ralf

    2017-09-01

    The Sentinel 4 instrument is an imaging spectrometer, developed by Airbus under ESA contract in the frame of the joint European Union (EU)/ESA COPERNICUS program with the objective of monitoring trace gas concentrations. Sentinel 4 will provide accurate measurements of key atmospheric constituents such as ozone, nitrogen dioxide, sulfur dioxide, formaldehyde, as well as aerosol and cloud properties. Sentinel 4 is unique in being the first geostationary UVN mission. The SENTINEL 4 space segment will be integrated on EUMETSAT's Meteosat Third Generation Sounder satellite (MTG-S). Sentinel 4 will provide coverage of Europe and adjacent regions. The Sentinel 4 instrument comprises as a major element two Focal Plane Subsystems (FPS) covering the wavelength ranges 305 nm to 500 nm (UVVIS) and 750 nm to 775 nm (NIR) respectively. The paper describes the Focal Plane Subsystems, comprising the detectors, the optical bench and the control electronics. Further the design and development approach will be presented as well as first measurement results of FPS Qualification Model.

  15. Comparison of anterior segment measurements using Sirius Topographer® and Nidek Axial Length-Scan® with assessing repeatability in patients with cataracts

    Directory of Open Access Journals (Sweden)

    Resat Duman

    2018-01-01

    Full Text Available Purpose: The purpose of this study is to evaluate anterior segment measurements obtained using CSO Sirius Topographer® (CSO, Firenze, Italy and Nidek Axial Length (AL-Scan® (Nidek CO., Gamagori, Japan. Methods: A total of 43 eyes of 43 patients were included in this prospective study. The central corneal thickness (CCT, anterior chamber depth (ACD, white-to-white distance (WTW, flat keratometry (K1, steep keratometry (K2, and mean keratometry (K values were randomly measured three times with each device by the same examiner. The intraclass correlation coefficient of repeatability was analyzed. The compatibility of both devices was evaluated using the 95% limits of the agreement proposed by Bland and Altman. Results: Examiner achieved high repeatability for all parameters on each device except the WTW measured by Sirius. All measurements except WTW and K1 taken with the Sirius were higher than that taken with the Nidek AL-Scan®. The difference in CCT, ACD, and WTW values was statistically significant. Conclusion: High repeatability of the measurements was achieved on both devices. Although Km, K1, and K2 measurements of the Sirius and the AL-Scan® showed good agreement, WTW, CCT, and ACD measurements significantly differed between two devices. Thus, anterior segment measurements except for Km, K1, and K2 cannot be used interchangeably between Sirius and Nidek AL-Scan® devices.

  16. Systems considerations in mosaic focal planes

    Science.gov (United States)

    White, K. P., III

    1983-08-01

    Two key reasons for pursuing the development of mosaic focal planes are reviewed and it is shown that rapid frame repetition rate is the only requirement that can be solved no other way than through mosaic focal planes. With the view that spaceborne mosaic focal plane sensors are necessarily 'smart sensors' requiring a lot of onboard processing just to function, it is pointed out that various artificial intelligence techniques may be the most appropriate to incorporate in the data processing. Finally, a novel mosaic focal plane design is proposed, termed a virtual mosaic focal plane, in response to other system constraints.

  17. TRIM15 is a focal adhesion protein that regulates focal adhesion disassembly

    Science.gov (United States)

    Uchil, Pradeep D.; Pawliczek, Tobias; Reynolds, Tracy D.; Ding, Siyuan; Hinz, Angelika; Munro, James B.; Huang, Fang; Floyd, Robert W.; Yang, Haitao; Hamilton, William L.; Bewersdorf, Joerg; Xiong, Yong; Calderwood, David A.; Mothes, Walther

    2014-01-01

    ABSTRACT Focal adhesions are macromolecular complexes that connect the actin cytoskeleton to the extracellular matrix. Dynamic turnover of focal adhesions is crucial for cell migration. Paxillin is a multi-adaptor protein that plays an important role in regulating focal adhesion dynamics. Here, we identify TRIM15, a member of the tripartite motif protein family, as a paxillin-interacting factor and a component of focal adhesions. TRIM15 localizes to focal contacts in a myosin-II-independent manner by an interaction between its coiled-coil domain and the LD2 motif of paxillin. Unlike other focal adhesion proteins, TRIM15 is a stable focal adhesion component with restricted mobility due to its ability to form oligomers. TRIM15-depleted cells display impaired cell migration and reduced focal adhesion disassembly rates, in addition to enlarged focal adhesions. Thus, our studies demonstrate a cellular function for TRIM15 as a regulatory component of focal adhesion turnover and cell migration. PMID:25015296

  18. MARBLE (Multiple Antenna Radio-interferometry for Baseline Length Evaluation): Development of a Compact VLBI System for Calibrating GNSS and Electronic Distance Measurement Devices

    Science.gov (United States)

    Ichikawa, R.; Ishii, A.; Takiguchi, H.; Kimura, M.; Sekido, M.; Takefuji, K.; Ujihara, H.; Hanado, Y.; Koyama, Y.; Kondo, T.; Kurihara, S.; Kokado, K.; Kawabata, R.; Nozawa, K.; Mukai, Y.; Kuroda, J.; Ishihara, M.; Matsuzaka, S.

    2012-12-01

    We are developing a compact VLBI system with a 1.6-m diameter aperture dish in order to provide reference baseline lengths for calibration. The reference baselines are used to validate surveying instruments such as GPS and EDM and is maintained by the Geospatial Information Authority of Japan (GSI). The compact VLBI system will be installed at both ends of the reference baseline. Since the system is not sensitive enough to detect fringes between the two small dishes, we have designed a new observation concept including one large dish station. We can detect two group delays between each compact VLBI system and the large dish station based on conventional VLBI measurement. A group delay between the two compact dishes can be indirectly calculated using a simple equation. We named the idea "Multiple Antenna Radio-interferometry for Baseline Length Evaluation", or MARBLE system. The compact VLBI system is easy transportable and consists of the compact dish, a new wide-band front-end system, azimuth and elevation drive units, an IF down-converter unit, an antenna control unit (ACU), a counterweight, and a monument pillar. Each drive unit is equipped with a zero-backlash harmonic drive gearing component. A monument pillar is designed to mount typical geodetic GNSS antennas easily and an offset between the GNSS antenna reference point. The location of the azimuth-elevation crossing point of the VLBI system is precisely determined with an uncertainty of less than 0.2 mm. We have carried out seven geodetic VLBI experiments on the Kashima-Tsukuba baseline (about 54 km) using the two prototypes of the compact VLBI system between December 2009 and December 2010. The average baseline length and repeatability of the experiments is 54184874.0 ± 2.4 mm. The results are well consistent with those obtained by GPS measurements. In addition, we are now planning to use the compact VLBI system for precise time and frequency comparison between separated locations.

  19. SNAP Satellite Focal Plane Development

    International Nuclear Information System (INIS)

    Bebek, C.; Akerlof, C.; Aldering, G.; Amanullah, R.; Astier, P.; Baltay, C.; Barrelet, E.; Basa, S.; Bercovitz, J.; Bergstrom, L.; Berstein, G.P.; Bester, M.; Bohlin, R.; Bonissent, A.; Bower, C.; Campbell, M.; Carithers, W.; Commins, E.; Day, C.; Deustua, S.; DiGennaro, R.; Ealet, A.; Ellis, R.; Emmett, W.; Eriksson, M.; Fouchez, D.; Fruchter, A.; Genat, J-F.; Goldhaber, G.; Goobar, A.; Groom, D.; Heetderks, H.; Holland, S.; Huterer, D.; Johnson, W.; Kadel, R.; Karcher, A.; Kim, A.; Kolbe, W.; Lafever, R.; Lamoureaux, J.; Lampton, M.; Lefevre, O.; Levi, M.; Levin, D.; Linder, E.; Loken, S.; Malina, R.; Mazure, A.; McKay, T.; McKee, S.; Miquel, R.; Morgan, N.; Mortsell, E.; Mostek, N.; Mufson, S.; Musser, J.; Roe, N.; Nugent, P.; Oluseyi, H.; Pain, R.; Palaio, N.; Pankow, D.; Perlmutter, S.; Prieto, E.; Rabinowitz, D.; Refregier, A.; Rhodes, J.; Schubnell, M.; Sholl, M.; Smadja, G.; Smith, R.; Smoot, G.; Snyder, J.; Spadafora, A.; Szymkowiak, A.; Tarle, G.; Taylor, K.; Tilquin, A.; Tomasch, A.; Vincent, D.; von der Lippe, H.; Walder, J-P.; Wang, G.

    2003-01-01

    The proposed SuperNova/Acceleration Probe (SNAP) mission will have a two-meter class telescope delivering diffraction-limited images to an instrumented 0.7 square degree field in the visible and near-infrared wavelength regime. The requirements for the instrument suite and the present configuration of the focal plane concept are presented. A two year R and D phase, largely supported by the Department of Energy, is just beginning. We describe the development activities that are taking place to advance our preparedness for mission proposal in the areas of detectors and electronics

  20. MRI of focal cortical dysplasia

    International Nuclear Information System (INIS)

    Lee, B.C.P.; Hatfield, G.A.; Bourgeois, B.; Park, T.S.

    1998-01-01

    We studied nine cases of focal cortical dysplasia (FCD) by MRI, with surface-rendered 3D reconstructions. One case was also examined using single-voxel proton MR spectroscopy (MRS). The histological features were reviewed and correlated with the MRI findings. The gyri affected by FCD were enlarged and the signal of the cortex was slightly increased on T1-weighted images. The gray-white junction was indistinct. Signal from the subcortical white matter was decreased on T1- and increased on T2-weighted images in most cases. Contrast enhancement was seen in two cases. Proton MRS showed a spectrum identical to that of normal brain. (orig.) (orig.)

  1. Interferon Induced Focal Segmental Glomerulosclerosis

    Directory of Open Access Journals (Sweden)

    Yusuf Kayar

    2016-01-01

    Full Text Available Behçet’s disease is an inflammatory disease of unknown etiology which involves recurring oral and genital aphthous ulcers and ocular lesions as well as articular, vascular, and nervous system involvement. Focal segmental glomerulosclerosis (FSGS is usually seen in viral infections, immune deficiency syndrome, sickle cell anemia, and hyperfiltration and secondary to interferon therapy. Here, we present a case of FSGS identified with kidney biopsy in a patient who had been diagnosed with Behçet’s disease and received interferon-alpha treatment for uveitis and presented with acute renal failure and nephrotic syndrome associated with interferon.

  2. Crosstalk between focal adhesions and material mechanical properties governs cell mechanics and functions.

    Science.gov (United States)

    Fusco, Sabato; Panzetta, Valeria; Embrione, Valerio; Netti, Paolo A

    2015-09-01

    Mechanical properties of materials strongly influence cell fate and functions. Focal adhesions are involved in the extremely important processes of mechanosensing and mechanotransduction. To address the relationship between the mechanical properties of cell substrates, focal adhesion/cytoskeleton assembly and cell functions, we investigated the behavior of NIH/3T3 cells over a wide range of stiffness (3-1000kPa) using two of the most common synthetic polymers for cell cultures: polyacrylamide and polydimethylsiloxane. An overlapping stiffness region was created between them to compare focal adhesion characteristics and cell functions, taking into account their different time-dependent behavior. Indeed, from a rheological point of view, polyacrylamide behaves like a strong gel (elastically), whereas polydimethylsiloxane like a viscoelastic solid. First, focal adhesion characteristics and dynamics were addressed in terms of material stiffness, then cell spreading area, migration rate and cell mechanical properties were correlated with focal adhesion size and assembly. Focal adhesion size was found to increase in the whole range of stiffness and to be in agreement in the overlapping rigidity region for the investigated materials. Cell mechanics directly correlated with focal adhesion lengths, whereas migration rate followed an inverse correlation. Cell spreading correlated with the substrate stiffness on polyacrylamide hydrogel, while no specific trend was found on polydimethylsiloxane. Substrate mechanics can be considered as a key physical cue that regulates focal adhesion assembly, which in turn governs important cellular properties and functions. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  3. Focal nodular hyperplasia in children

    International Nuclear Information System (INIS)

    Mancheva, Ts.; El Shemeri, S.; Balev, B.; Rasheva, N.; Georgieva, M.

    2016-01-01

    Focal nodular hyperplasia (FNH) is a rare benign tumor of the liver, which is extremely rare reported in children. We present a case of 6-month-old female. The infant was referred to the hospital for further investigation of incidentally established heterodense mass in the liver. Ultrasound and CT examinations were performed. They were combined with laboratory and viral serologic tests. The liver function tests were normal, except AFP. Viral serologic tests for hepatitis B and C were negative. Abdominal ultrasound revealed a heterodense mass, well-defined from the surrounding liver tissue. On Doppler examination, the blood supply is proven to be from a large artery. The findings on CT imaging include a solitary, homogeneous, and slightly hypoattenuating mass compared to the surrounding liver on unenhanced CT. After administration of i.v. contrast the lesion demonstrates rapid homogeneous contrast enhancement at the arterial phase (except for the central scar). On venous phase, the mass becomes isotense as compared to the surrounding liver. Although the diagnosis of FNH in children can be challenging for the radiologist, different imaging modalities like ultrasound, CT and MRI all offer specific advantages in the detection. Key words: FOCAL Nodular Hyperplasia. Imaging Diagnostic. Pediatric. Tumours In Children

  4. Validation of Transient Elastography and Comparison with Spleen Length Measurement for Staging of Fibrosis and Clinical Prognosis in Primary Sclerosing Cholangitis.

    Directory of Open Access Journals (Sweden)

    Hanno Ehlken

    Full Text Available Patients with primary sclerosing cholangitis (PSC develop progressive liver fibrosis and end-stage liver disease. Non-invasive and widely available parameters are urgently needed to assess disease stage and the risk of clinical progression. Transient elastography (TE has been reported to predict fibrosis stage and disease progression. However, these results have not been confirmed in an independent cohort and comparison of TE measurement to other non-invasive means is missing.In a retrospective study we collected data from consecutive PSC patients receiving TE measurements from 2006 to 2014 (n = 139. Data from 62 patients who also underwent a liver biopsy were used to assess the performance of TE and spleen length (SL measurement for the staging of liver fibrosis. Follow-up data from this cohort (n = 130, Hamburg and another independent cohort (n = 80, Paris was used to compare TE and SL as predictors of clinical outcome applying Harrel's C calculations.TE measurement had a very good performance for the diagnosis and exclusion of higher fibrosis stages (≥F3: AUROC 0.95 and an excellent performance for the diagnosis and exclusion of cirrhosis (F4 vs. < F4: AUROC 0.98. Single-point TE measurement had very similar predictive power for patient outcome as previously published. In a combined cohort of PSC patients (n = 210, SL measurements had a similar performance as TE for the prediction of patient outcome (5 x cross-validated Harrel's C 0.76 and 0.72 for SL and TE, respectively.Baseline TE measurement has an excellent performance to diagnose higher fibrosis stages in PSC. Baseline measurements of SL and TE have similar usefulness as predictive markers for disease progression in patients with PSC.

  5. The influence of NDT-Bobath and PNF methods on the field support and total path length measure foot pressure (COP) in patients after stroke.

    Science.gov (United States)

    Krukowska, Jolanta; Bugajski, Marcin; Sienkiewicz, Monika; Czernicki, Jan

    In stroke patients, the NDT - (Bobath - Neurodevelopmental Treatment) and PNF (Proprioceptive Neuromuscular Facilitation) methods are used to achieve the main objective of rehabilitation, which aims at the restoration of maximum patient independence in the shortest possible period of time (especially the balance of the body). The aim of the study is to evaluate the effect of the NDT-Bobath and PNF methods on the field support and total path length measure foot pressure (COP) in patients after stroke. The study included 72 patients aged from 20 to 69 years after ischemic stroke with Hemiparesis. The patients were divided into 4 groups by a simple randomization. The criteria for this division were: the body side (right or left) affected by paresis and the applied rehabilitation methods. All the patients were applied the recommended kinesitherapeutic method (randomized), 35 therapy sessions, every day for a period of six weeks. Before initiation of therapy and after 6 weeks was measured the total area of the support and path length (COP (Center Of Pressure) measure foot pressure) using stabilometer platform - alpha. The results were statistically analyzed. After treatment studied traits decreased in all groups. The greatest improvement was obtained in groups with NDT-Bobath therapy. NDT-Bobath method for improving the balance of the body is a more effective method of treatment in comparison with of the PNF method. In stroke patients, the effectiveness of NDT-Bobath method does not depend on hand paresis. Copyright © 2016 Polish Neurological Society. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.

  6. Correspondence optimization in 2D standardized carotid wall thickness map by description length minimization: A tool for increasing reproducibility of 3D ultrasound-based measurements.

    Science.gov (United States)

    Chen, Yimin; Chiu, Bernard

    2016-12-01

    The previously described 2D standardized vessel-wall-plus-plaque thickness (VWT) maps constructed from 3D ultrasound vessel wall measurements using an arc-length (AL) scaling approach adjusted the geometric variability of carotid arteries and has allowed for the comparisons of VWT distributions in longitudinal and cross-sectional studies. However, this mapping technique did not optimize point correspondence of the carotid arteries investigated. The potential misalignment may lead to errors in point-wise VWT comparisons. In this paper, we developed and validated an algorithm based on steepest description length (DL) descent to optimize the point correspondence implied by the 2D VWT maps. The previously described AL approach was applied to obtain initial 2D maps for a group of carotid arteries. The 2D maps were reparameterized based on an iterative steepest DL descent approach, which consists of the following two steps. First, landmarks established by resampling the 2D maps were aligned using the Procrustes algorithm. Then, the gradient of the DL with respect to horizontal and vertical reparameterizations of each landmark on the 2D maps was computed, and the 2D maps were subsequently deformed in the direction of the steepest descent of DL. These two steps were repeated until convergence. The quality of the correspondence was evaluated in a phantom study and an in vivo study involving ten carotid arteries enrolled in a 3D ultrasound interscan variability study. The correspondence quality was evaluated in terms of the compactness and generalization ability of the statistical shape model built based on the established point correspondence in both studies. In the in vivo study, the effect of the proposed algorithm on interscan variability of VWT measurements was evaluated by comparing the percentage of landmarks with statistically significant VWT-change before and after point correspondence optimization. The statistical shape model constructed with optimized

  7. Comparison of fiber length analyzers

    Science.gov (United States)

    Don Guay; Nancy Ross Sutherland; Walter Rantanen; Nicole Malandri; Aimee Stephens; Kathleen Mattingly; Matt Schneider

    2005-01-01

    In recent years, several fiber new fiber length analyzers have been developed and brought to market. The new instruments provide faster measurements and the capability of both laboratory and on-line analysis. Do the various fiber analyzers provide the same length, coarseness, width, and fines measurements for a given fiber sample? This paper provides a comparison of...

  8. Measurement of Pion and Proton Response and Longitudinal Shower Profiles up to 20 Nuclear Interaction Lengths with the ATLAS Tile Calorimeter

    CERN Document Server

    Adragna, P; Anderson, K; Antonaki, A; Arabidze, A; Batkova, L; Batusov, V; Beck, H P; Bergeaas Kuutmann, E; Biscarat, C; Blanchot, G; Bogush, A; Bohm, C; Boldea, V; Bosman, M; Bromberg, C; Budagov, J; Burckhart-Chromek, D; Caprini, M; Caloba, L; Calvet, D; Carli, T; Carvalho, J; Cascella, M; Castelo, J; Castillo, M V; Cavalli-Sforza, M; Cavasinni, V; Cerqueira, A S; Clement, C; Cobal, M; Cogswell, F; Constantinescu, S; Costanzo, D; Corso-Radu, A; Cuenca, C; Damazio, D O; Davidek, T; De, K; Del Prete, T; Di Girolamo, B; Dita, S; Djobava, T; Dobson, M; Dotti, A; Downing, R; Efthymiopoulos, I; Eriksson, D; Errede, D; Errede, S; Farbin, A; Fassouliotis, D; Febbraro, R; Fenyuk, A; Ferdi, C; Ferrer, A; Flaminio, V; Francis, D; Fullana, E; Gadomski, S; Gameiro, S; Garde, V; Gellerstedt, K; Giakoumopoulou, V; Gildemeister, O; Gilewsky, V; Giokaris, N; Gollub, N; Gomes, A; Gonzalez, V; Gorini, B; Grenier, P; Gris, P; Gruwe, M; Guarino, V; Guicheney, C; Gupta, A; Haeberli, C; Hakobyan, H; Haney, M; Hellman, S; Henriques, A; Higon, E; Holmgren, S; Hurwitz, M; Huston, J; Iglesias, C; Isaev, A; Jen-La Plante, I; Jon-And, K; Joos, M; Junk, T; Karyukhin, A; Kazarov, A; Khandanyan, H; Khramov, J; Khubua, J; Kolos, S; Korolkov, I; Krivkova, P; Kulchitsky, Y; Kurochkin, Yu; Kuzhir, P; LeCompte, T; Lefevre, R; Lehmann, G; Leitner, R; Lembesi, M; Lesser, J; Li, J; Liablin, M; Lokajicek, M; Lomakin, Y; Lupi, A; Maidanchik, C; Maio, A; Makouski, M; Maliukov, S; Manousakis, A; Mapelli, L; Marques, C; Marroquim, F; Martin, F; Mazzoni, E; Merritt, F; Miagkov, A; Miller, R; Minashvili, I; Miralles, L; Montarou, G; Mosidze, M; Myagkov, A; Nemecek, S; Nessi, M; Nodulman, L; Nordkvist, B; Norniella, O; Novakova, J; Onofre, A; Oreglia, M; Pallin, D; Pantea, D; Petersen, J; Pilcher, J; Pina, J; Pinhao, J; Podlyski, F; Portell Bueso, X; Poveda, J; Pribyl, L; Price, L E; Proudfoot, J; Ramstedt, M; Richards, R; Roda, C; Romanov, V; Rosnet, P; Roy, P; Ruiz, A; Rumiantsev, V; Russakovich, N; Salto, O; Salvachua, B; Sanchis, E; Sanders, H; Santoni, C; Saraiva, J G; Sarri, F; Satsunkevitch, I; Says, L P; Schlager, G; Schlereth, J; Seixas, J M; Sellden, B; Shalanda, N; Shevtsov, P; Shochet, M; Silva, J; Da Silva, P; Simaitis, V; Simonyan, M; Sissakian, A; Sjolin, J; Solans, C; Solodkov, A; Soloviev, I; Solovyanov, O; Sosebee, M; Spano, F; Stanek, R; Starchenko, E; Starovoitov, P; Stavina, P; Suk, M; Sykora, I; Tang, F; Tas, P; Teuscher, R; Tokar, S; Topilin, N; Torres, J; Tremblet, L; Tsiareshka, P; Tylmad, M; Underwood, D; Unel, G; Usai, G; Valero, A; Valkar, S; Valls, J A; Vartapetian, A; Vazeille, F; Vichou, I; Vinogradov, V; Vivarelli, I; Volpi, M; White, A; Zaitsev, A; Zenine, A; Zenis, T

    2010-01-01

    The response of pions and protons in the energy range of 20 to 180 GeV produced at CERN's SPS H8 test beam line in the ATLAS iron-scintillator Tile hadron calorimeter has been measured. The test-beam configuration allowed to measure the longitudinal shower development for pions and protons up to 20 nuclear interaction lengths. It is found that pions penetrate deeper in the calorimeter than protons. However, protons induce showers that are wider laterally to the direction of the impinging particle. Including the measured total energy response, the pion to proton energy ratio and the resolution, all observations are consistent with a higher electromagnetic energy fraction in pion induced showers. The data are compared with GEANT4 simulations using several hadronic physics lists. The measured longitudinal shower profiles are described by an analytical shower parameterization within an accuracy of 5-10%. The amount of energy leaking out behind the calorimeter is determined and parameterised as a function of the b...

  9. Regional cerebral blood flow in focal cortical epilepsy

    DEFF Research Database (Denmark)

    Hougaard, Kristina Dupont; Oikawa, T; Sveinsdottir, E

    1976-01-01

    Regional cerebral blood flow (rCBF) was studied in ten patients with focal cortical epilepsy. The blood flow was measured by the intra-arterial injection of xenon 133 (133Xe), and the isotope clearance was recorded by a multidetector scintillation camera with 254 detectors. Three patients were st...

  10. Regional cerebral blood flow in focal cortical epilepsy

    DEFF Research Database (Denmark)

    Hougaard, Kristina Dupont; Oikawa, T; Sveinsdottir, E

    1976-01-01

    Regional cerebral blood flow (rCBF) was studied in ten patients with focal cortical epilepsy. The blood flow was measured by the intra-arterial injection of xenon 133 (133Xe), and the isotope clearance was recorded by a multidetector scintillation camera with 254 detectors. Three patients were...

  11. RTG diagnostics of dental focal infection

    International Nuclear Information System (INIS)

    Petrasova, A.; Ondrasovicova, J.; Cecctkova, A.

    2008-01-01

    The theory of focal infection has always been and still is a controversial issue for many dentists and scientists. Even though the focal infection does not occupy the first place in modern medicine, its understanding is imperative. The authors summarized the knowledge about dental focal infection and its relationship to systemic the diseases of the whole body in their publication and they also focused on the radiodiagnostics of this disease. (authors)

  12. Periodontitis in patients with focal tuberculosis

    Directory of Open Access Journals (Sweden)

    Alexandrova Е.А.

    2010-12-01

    Full Text Available The research goal is to investigate the mechanisms of formation and peculiarities of periodontitis in patients with focal tuberculosis. Patients with periodontitis and focal tuberculosis are proved to develop local inflammatory reaction with increased infection and activation of proinflammatory cytokines in parodontal pockets fluid. The main risk factor of frequent and durable recurrence of parodontal pathology in case of focal tuberculosis was the development of pathologic process as a cause of disbalance of lipid peroxidation and antioxidant system, endotoxicosis syndrome

  13. Idiopathic focal epilepsies: the "lost tribe".

    Science.gov (United States)

    Pal, Deb K; Ferrie, Colin; Addis, Laura; Akiyama, Tomoyuki; Capovilla, Giuseppe; Caraballo, Roberto; de Saint-Martin, Anne; Fejerman, Natalio; Guerrini, Renzo; Hamandi, Khalid; Helbig, Ingo; Ioannides, Andreas A; Kobayashi, Katsuhiro; Lal, Dennis; Lesca, Gaetan; Muhle, Hiltrud; Neubauer, Bernd A; Pisano, Tiziana; Rudolf, Gabrielle; Seegmuller, Caroline; Shibata, Takashi; Smith, Anna; Striano, Pasquale; Strug, Lisa J; Szepetowski, Pierre; Valeta, Thalia; Yoshinaga, Harumi; Koutroumanidis, Michalis

    2016-09-01

    epigenetic factors involved that might also explain low observed twin concordance? The genetic (and epigenetic) models for different IFEs, their comorbidities, and their similarities to other neurodevelopmental disorders deserve investigation in the coming years. In so doing, we will probably learn much about normal brain functioning. This is because these disorders, perhaps more than any other human brain disease, are disorders of functional brain systems (even though these functional networks may not yet be fully defined). In June 2012, an international group of clinical and basic science researchers met in London under the auspices of the Waterloo Foundation to discuss and debate these issues in relation to IFEs. This Waterloo Foundation Symposium on the Idiopathic Focal Epilepsies: Phenotype to Genotype witnessed presentations that explored the clinical phenomenology, phenotypes and endophenotypes, and genetic approaches to investigation of these disorders. In parallel, the impact of these epilepsies on children and their families was reviewed. The papers in this supplement are based upon these presentations. They represent an updated state-of-the-art thinking on the topics explored. The symposium led to the formation of international working groups under the umbrella of "Luke's Idiopathic Focal Epilepsy Project" to investigate various aspects of the idiopathic focal epilepsies including: semiology and classification, genetics, cognition, sleep, high-frequency oscillations, and parental resources (see www.childhood-epilepsy.org). The next sponsored international workshop, in June 2014, was on randomised controlled trials in IFEs and overnight learning outcome measures.

  14. Lengths of Schwabe cycles in the seventh and eighth centuries indicated by precise measurement of carbon-14 content in tree rings

    Science.gov (United States)

    Miyake, Fusa; Masuda, Kimiaki; Nakamura, Toshio

    2013-12-01

    (14C) is produced in the atmosphere by galactic cosmic rays, which are modulated by solar magnetic activity. Its content in tree rings is retained and provides a record of past cosmic ray intensity and solar activity. We have measured, with 2 year resolution, the 14C content in Japanese cedar tree rings for the period A.D. 600 to 760, which includes a small grand solar minimum in the seventh to eighth centuries. Periodicity analysis of the 14C data shows that there is a component in the frequency band of the Schwabe cycle, with a period of 12-13 years continuing throughout the minimum. This is the fourth case in which an increase in the length of the Schwabe cycle has been observed in a grand solar minimum, after the Maunder Minimum, the Spörer Minimum, and the Fourth Century B.C. Minimum.

  15. Measurement of the penetration depth and coherence length of MgB2 in all directions using transmission electron microscopy

    DEFF Research Database (Denmark)

    Loudon, J. C.; Yazdi, Sadegh; Kasama, Takeshi

    2015-01-01

    lengths. This gave penetration depths Lambda(ab) = 100 +/- 35 nm and Lambda(c) = 120 +/- 15 nm at 10.8 K in a field of 4.8 mT. The large error in Lambda(ab) is a consequence of tilting the sample about a and had it been tilted about c, the errors on Lambda(ab) and Lambda(c) would be reversed. Thus...... gives Lambda(ab) = 107 +/- 8 nm, Lambda(c) = 120 +/- 15 nm, xi(ab) = 39 +/- 11 nm, and xi(c) = 35 +/- 10 nm, which agree well with measurements made using other techniques. The experiment required two days to conduct and does not require large-scale facilities. It was performed on a very small sample...

  16. Large Format Uncooled Focal Plane Array Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Black Forest Engineering has identified innovative modifications in uncooled focal plane array (UFPA) architecture and processing that allows development of large...

  17. Flux dynamics in ultrasensitive superconducting focal planes

    Data.gov (United States)

    National Aeronautics and Space Administration — The performance of superconducting focal planes will drive the achievable specifications of ultrasensitive instruments for NASA astrophysics missions, yet they have...

  18. Game Movement as Enactive Focalization

    Directory of Open Access Journals (Sweden)

    Yotam Shibolet

    2018-01-01

    Full Text Available This paper integrates thought on game narrative and embodied cognition, in order to consider the significance of movement to the embodied narrative experience of games. If games are a mode of ‘environmental storytelling’, determining the player’s mobile situatedness within the gamespace is of crucial importance. The metaphor of game design as narrative architecture should be expanded to include te the design of movement dynamics, alongside geographical gamespace. I suggest a theoretical infrastructure that aims to enable further analysis of movement design’s role in this scope. The theory of enactive perception asserts that all perception is inherently negotiated through embodied understanding of moving within environment. According to this model, by giving meaning to perception, movement is also directly related to the structure of consciousness and thought. Cognitive definitions of ‘narrative’ that integrate embodiment are applied to argue it can relevantly account for part of thought’s role in enactive perception. Mieke Bal’s concept of focalization (1997 broaches narrative perspective by underscoring the constant “movement of the look”. For enactive perception, such mobility should be understood as inseparable from the movement of the body even when perspective could appear detached from embodiment. Therefore, I offer the supplementary concept of “enactive focalization” – narrative perception as interpreted through the interconnected dynamics or perspectival and physical movement. To exemplify my ideas and the potential of future research in this scope, I discuss the uniquely effective and affective movement dynamic design of Journey. This paper concludes by reflecting on enactive focalization in light of the increased utilization of embodiment in the contemporary digital media landscape.

  19. Wavelet Imaging on Multiple Scales (WIMS) reveals focal adhesion distributions, dynamics and coupling between actomyosin bundle stability

    Science.gov (United States)

    Toplak, Tim; Palmieri, Benoit; Juanes-García, Alba; Vicente-Manzanares, Miguel; Grant, Martin; Wiseman, Paul W.

    2017-01-01

    We introduce and use Wavelet Imaging on Multiple Scales (WIMS) as an improvement to fluorescence correlation spectroscopy to measure physical processes and features that occur across multiple length scales. In this study, wavelet transforms of cell images are used to characterize molecular dynamics at the cellular and subcellular levels (i.e. focal adhesions). We show the usefulness of the technique by applying WIMS to an image time series of a migrating osteosarcoma cell expressing fluorescently labelled adhesion proteins, which allows us to characterize different components of the cell ranging from optical resolution scale through to focal adhesion and whole cell size scales. Using WIMS we measured focal adhesion numbers, orientation and cell boundary velocities for retraction and protrusion. We also determine the internal dynamics of individual focal adhesions undergoing assembly, disassembly or elongation. Thus confirming as previously shown, WIMS reveals that the number of adhesions and the area of the protruding region of the cell are strongly correlated, establishing a correlation between protrusion size and adhesion dynamics. We also apply this technique to characterize the behavior of adhesions, actin and myosin in Chinese hamster ovary cells expressing a mutant form of myosin IIB (1935D) that displays decreased filament stability and impairs front-back cell polarity. We find separate populations of actin and myosin at each adhesion pole for both the mutant and wild type form. However, we find these populations move rapidly inwards toward one another in the mutant case in contrast to the cells that express wild type myosin IIB where those populations remain stationary. Results obtained with these two systems demonstrate how WIMS has the potential to reveal novel correlations between chosen parameters that belong to different scales. PMID:29049414

  20. Abnormalities of spatial discrimination in focal and generalized dystonia.

    Science.gov (United States)

    Molloy, F M; Carr, T D; Zeuner, K E; Dambrosia, J M; Hallett, M

    2003-10-01

    Sensory processing is impaired in focal hand dystonia (FHD), with most previous studies having evaluated only the symptomatic limb. The purpose of this study was to establish whether the sensory system is affected in other types of dystonias and whether the contralateral hand is also involved in FHD. We used a spatial acuity measure (Johnson-Van Boven-Phillips domes) to evaluate sensory spatial discrimination in both hands of patients with different forms of dystonias including primary generalized DYT1 dystonia (associated with a unique deletion in the DYT1 gene) (n = 13), FHD (n = 15), benign essential blepharospasm (n = 9), cervical dystonia (n = 10) and in age-matched controls. Clinical evaluation included the Fahn dystonia scale for the focal dystonia groups and the Marsden-Burke-Fahn scale for the generalized dystonia group. Spatial discrimination was normal in patients with DYT1 dystonia, despite all of these patients having hand dystonia. However, spatial discrimination thresholds were significantly increased in both hands in the focal dystonia groups (thresholds were similar for each group) and did not correlate significantly with either severity or duration of dystonic symptoms. Thresholds were significantly increased in the dominant hand compared with the non-dominant hand only within the FHD group. Our observations demonstrate involvement of both the dominant and non-dominant somatosensory cortices, and suggest that abnormal sensory processing is a fundamental disturbance in patients with focal dystonia. These findings of altered sensory processing in idiopathic focal but not generalized DYT1 dystonia suggest both a primary pathophysiological role for the phenomenon in focal dystonia and divergent pathophysiological processes in the two conditions.

  1. Progress in Long Scale Length Laser-Plasma Interactions

    International Nuclear Information System (INIS)

    Glenzer, S H; Arnold, P; Bardsley, G; Berger, R L; Bonanno, G; Borger, T; Bower, D E; Bowers, M; Bryant, R; Buckman, S.; Burkhart, S C; Campbell, K; Chrisp, M P; Cohen, B I; Constantin, G; Cooper, F; Cox, J; Dewald, E; Divol, L; Dixit, S; Duncan, J; Eder, D; Edwards, J; Erbert, G; Felker, B; Fornes, J; Frieders, G; Froula, D H; Gardner, S D; Gates, C; Gonzalez, M; Grace, S; Gregori, G; Greenwood, A; Griffith, R; Hall, T; Hammel, B A; Haynam, C; Heestand, G; Henesian, M; Hermes, G; Hinkel, D; Holder, J; Holdner, F; Holtmeier, G; Hsing, W; Huber, S; James, T; Johnson, S; Jones, O S; Kalantar, D; Kamperschroer, J H; Kauffman, R; Kelleher, T; Knight, J; Kirkwood, R K; Kruer, W L; Labiak, W; Landen, O L; Langdon, A B; Langer, S; Latray, D; Lee, A; Lee, F D; Lund, D; MacGowan, B; Marshall, S; McBride, J; McCarville, T; McGrew, L; Mackinnon, A J; Mahavandi, S; Manes, K; Marshall, C; Mertens, E; Meezan, N; Miller, G; Montelongo, S; Moody, J D; Moses, E; Munro, D; Murray, J; Neumann, J; Newton, M; Ng, E; Niemann, C; Nikitin, A; Opsahl, P; Padilla, E; Parham, T; Parrish, G; Petty, C; Polk, M; Powell, C; Reinbachs, I; Rekow, V; Rinnert, R; Riordan, B; Rhodes, M.

    2003-01-01

    The first experiments on the National Ignition Facility (NIF) have employed the first four beams to measure propagation and laser backscattering losses in large ignition-size plasmas. Gas-filled targets between 2 mm and 7 mm length have been heated from one side by overlapping the focal spots of the four beams from one quad operated at 351 nm (3ω) with a total intensity of 2 x 10 15 W cm -2 . The targets were filled with 1 atm of CO 2 producing of up to 7 mm long homogeneously heated plasmas with densities of n e = 6 x 10 20 cm -3 and temperatures of T e = 2 keV. The high energy in a NIF quad of beams of 16kJ, illuminating the target from one direction, creates unique conditions for the study of laser plasma interactions at scale lengths not previously accessible. The propagation through the large-scale plasma was measured with a gated x-ray imager that was filtered for 3.5 keV x rays. These data indicate that the beams interact with the full length of this ignition-scale plasma during the last ∼1 ns of the experiment. During that time, the full aperture measurements of the stimulated Brillouin scattering and stimulated Raman scattering show scattering into the four focusing lenses of 6% for the smallest length (∼2 mm). increasing to 12% for ∼7 mm. These results demonstrate the NIF experimental capabilities and further provide a benchmark for three-dimensional modeling of the laser-plasma interactions at ignition-size scale lengths

  2. Progress in long scale length laser plasma interactions

    Science.gov (United States)

    Glenzer, S. H.; Arnold, P.; Bardsley, G.; Berger, R. L.; Bonanno, G.; Borger, T.; Bower, D. E.; Bowers, M.; Bryant, R.; Buckman, S.; Burkhart, S. C.; Campbell, K.; Chrisp, M. P.; Cohen, B. I.; Constantin, C.; Cooper, F.; Cox, J.; Dewald, E.; Divol, L.; Dixit, S.; Duncan, J.; Eder, D.; Edwards, J.; Erbert, G.; Felker, B.; Fornes, J.; Frieders, G.; Froula, D. H.; Gardner, S. D.; Gates, C.; Gonzalez, M.; Grace, S.; Gregori, G.; Greenwood, A.; Griffith, R.; Hall, T.; Hammel, B. A.; Haynam, C.; Heestand, G.; Henesian, M.; Hermes, G.; Hinkel, D.; Holder, J.; Holdner, F.; Holtmeier, G.; Hsing, W.; Huber, S.; James, T.; Johnson, S.; Jones, O. S.; Kalantar, D.; Kamperschroer, J. H.; Kauffman, R.; Kelleher, T.; Knight, J.; Kirkwood, R. K.; Kruer, W. L.; Labiak, W.; Landen, O. L.; Langdon, A. B.; Langer, S.; Latray, D.; Lee, A.; Lee, F. D.; Lund, D.; MacGowan, B.; Marshall, S.; McBride, J.; McCarville, T.; McGrew, L.; Mackinnon, A. J.; Mahavandi, S.; Manes, K.; Marshall, C.; Menapace, J.; Mertens, E.; Meezan, N.; Miller, G.; Montelongo, S.; Moody, J. D.; Moses, E.; Munro, D.; Murray, J.; Neumann, J.; Newton, M.; Ng, E.; Niemann, C.; Nikitin, A.; Opsahl, P.; Padilla, E.; Parham, T.; Parrish, G.; Petty, C.; Polk, M.; Powell, C.; Reinbachs, I.; Rekow, V.; Rinnert, R.; Riordan, B.; Rhodes, M.; Roberts, V.; Robey, H.; Ross, G.; Sailors, S.; Saunders, R.; Schmitt, M.; Schneider, M. B.; Shiromizu, S.; Spaeth, M.; Stephens, A.; Still, B.; Suter, L. J.; Tietbohl, G.; Tobin, M.; Tuck, J.; Van Wonterghem, B. M.; Vidal, R.; Voloshin, D.; Wallace, R.; Wegner, P.; Whitman, P.; Williams, E. A.; Williams, K.; Winward, K.; Work, K.; Young, B.; Young, P. E.; Zapata, P.; Bahr, R. E.; Seka, W.; Fernandez, J.; Montgomery, D.; Rose, H.

    2004-12-01

    The first experiments on the National Ignition Facility (NIF) have employed the first four beams to measure propagation and laser backscattering losses in large ignition-size plasmas. Gas-filled targets between 2 and 7 mm length have been heated from one side by overlapping the focal spots of the four beams from one quad operated at 351 nm (3ω) with a total intensity of 2 × 1015 W cm-2. The targets were filled with 1 atm of CO2 producing up to 7 mm long homogeneously heated plasmas with densities of ne = 6 × 1020 cm-3 and temperatures of Te = 2 keV. The high energy in an NIF quad of beams of 16 kJ, illuminating the target from one direction, creates unique conditions for the study of laser-plasma interactions at scale lengths not previously accessible. The propagation through the large-scale plasma was measured with a gated x-ray imager that was filtered for 3.5 keV x-rays. These data indicate that the beams interact with the full length of this ignition-scale plasma during the last ~1 ns of the experiment. During that time, the full aperture measurements of the stimulated Brillouin scattering and stimulated Raman scattering show scattering into the four focusing lenses of 3% for the smallest length (~2 mm), increasing to 10-12% for ~7 mm. These results demonstrate the NIF experimental capabilities and further provide a benchmark for three-dimensional modelling of the laser-plasma interactions at ignition-size scale lengths.

  3. Measurement of product of solid state laser materials by an ...

    Indian Academy of Sciences (India)

    In this method a microchip laser is formed by keeping a small piece of the sample in plane–plane resonator and a diode laser (808 nm) is used for pumping. The pump power induced thermal lensing effect is used to make the cavity stable. The cavity mode area is estimated by measuring the thermal lens focal length at the ...

  4. Prenatal sonographic diagnosis of focal musculoskeletal anomalies

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jung Kyu; Cho, Jeong Yeon; Lee, Young Ho; Kim, Ei Jeong; Chun, Yi Kyeong [Samsung Cheil Hospital, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2002-09-15

    Focal musculoskeletal anomalies are various and may be an isolated finding or may be found in conjunction with numerous associations, including genetic syndromes, Karyotype abnormals, central nervous system anomalies and other general musculoskeletal disorders. Early prenatal diagnosis of these focal musculoskeletal anomalies nor only affects prenatal care and postnatal outcome but also helps in approaching other numerous associated anomalies.

  5. Prenatal sonographic diagnosis of focal musculoskeletal anomalies

    International Nuclear Information System (INIS)

    Ryu, Jung Kyu; Cho, Jeong Yeon; Lee, Young Ho; Kim, Ei Jeong; Chun, Yi Kyeong

    2002-01-01

    Focal musculoskeletal anomalies are various and may be an isolated finding or may be found in conjunction with numerous associations, including genetic syndromes, Karyotype abnormals, central nervous system anomalies and other general musculoskeletal disorders. Early prenatal diagnosis of these focal musculoskeletal anomalies nor only affects prenatal care and postnatal outcome but also helps in approaching other numerous associated anomalies.

  6. Measuring the amount of serum albumin in burn patients and the relationship between the burned area and length of hospital stay

    Directory of Open Access Journals (Sweden)

    Maryam Roham

    2017-08-01

    Methods: This cross-sectional study was conducted on patients aged over 16 years who referred to the Motahari Hospital of September 2014 to February 2015 in the first 24 hours of their referral. The amount of Albumin was measured in two groups of discharged patients and patients who died while hospitalized, one week after hospital stay and in the time of discharge and death; and its relationship in terms of each other was determined by statistical analysis. We also assessed the relationship between burn and duration of hospital stay with the amount of Albumin on the day of patient’s admission. Results: This study showed that the average amount of albumin in the group of discharged patients in the time of admission, one week after and during admission was significantly higher than the group of expired patients (P<0.0001. Also there was a significant relation between the burned area and the amount of albumin (P<0.0001. The more the burned area, the less the amount of Albumin. But there was no significant relationship between the amount of albumin with age and length of hospital stay. Conclusion: Measuring the level of Albumin is one of the yardsticks that can be used for prognosis of recovery or death of burn patients, and its assessment at regular intervals in burn patients is essential.

  7. Focal osteoporosis defects play a key role in hip fracture.

    Science.gov (United States)

    Poole, Kenneth E S; Skingle, Linda; Gee, Andrew H; Turmezei, Thomas D; Johannesdottir, Fjola; Blesic, Karen; Rose, Collette; Vindlacheruvu, Madhavi; Donell, Simon; Vaculik, Jan; Dungl, Pavel; Horak, Martin; Stepan, Jan J; Reeve, Jonathan; Treece, Graham M

    2017-01-01

    Hip fractures are mainly caused by accidental falls and trips, which magnify forces in well-defined areas of the proximal femur. Unfortunately, the same areas are at risk of rapid bone loss with ageing, since they are relatively stress-shielded during walking and sitting. Focal osteoporosis in those areas may contribute to fracture, and targeted 3D measurements might enhance hip fracture prediction. In the FEMCO case-control clinical study, Cortical Bone Mapping (CBM) was applied to clinical computed tomography (CT) scans to define 3D cortical and trabecular bone defects in patients with acute hip fracture compared to controls. Direct measurements of trabecular bone volume were then made in biopsies of target regions removed at operation. The sample consisted of CT scans from 313 female and 40 male volunteers (158 with proximal femoral fracture, 145 age-matched controls and 50 fallers without hip fracture). Detailed Cortical Bone Maps (c.5580 measurement points on the unfractured hip) were created before registering each hip to an average femur shape to facilitate statistical parametric mapping (SPM). Areas where cortical and trabecular bone differed from controls were visualised in 3D for location, magnitude and statistical significance. Measures from the novel regions created by the SPM process were then tested for their ability to classify fracture versus control by comparison with traditional CT measures of areal Bone Mineral Density (aBMD). In women we used the surgical classification of fracture location ('femoral neck' or 'trochanteric') to discover whether focal osteoporosis was specific to fracture type. To explore whether the focal areas were osteoporotic by histological criteria, we used micro CT to measure trabecular bone parameters in targeted biopsies taken from the femoral heads of 14 cases. Hip fracture patients had distinct patterns of focal osteoporosis that determined fracture type, and CBM measures classified fracture type better than a

  8. Position sensitive proportional counters as focal plane detectors

    International Nuclear Information System (INIS)

    Ford, J.L.C. Jr.

    1979-01-01

    The rise time and charge division techniques for position decoding with RC-line proportional counters are reviewed. The advantages that these detectors offer as focal plane counters for nuclear spectroscopy performed with magnetic spectrographs are discussed. The theory of operation of proportional counters as position sensing devices is summarized, as well as practical aspects affecting their application. Factors limiting the position and energy resolutions obtainable with a focal plane proportional counter are evaluated and measured position and energy loss values are presented for comparison. Detector systems capable of the multiparameter measurements required for particle identification, background suppression and ray-tracing are described in order to illustrate the wide applicability of proportional counters within complex focal plane systems. Examples of the use of these counters other than with magnetic spectrographs are given in order to demonstrate their usefulness in not only nuclear physics but also in fields such as solid state physics, biology, and medicine. The influence of the new focal plane detector systems on future magnetic spectrograph designs is discussed. (Auth.)

  9. Early vision and focal attention

    Science.gov (United States)

    Julesz, Bela

    1991-07-01

    At the thirty-year anniversary of the introduction of the technique of computer-generated random-dot stereograms and random-dot cinematograms into psychology, the impact of the technique on brain research and on the study of artificial intelligence is reviewed. The main finding-that stereoscopic depth perception (stereopsis), motion perception, and preattentive texture discrimination are basically bottom-up processes, which occur without the help of the top-down processes of cognition and semantic memory-greatly simplifies the study of these processes of early vision and permits the linking of human perception with monkey neurophysiology. Particularly interesting are the unexpected findings that stereopsis (assumed to be local) is a global process, while texture discrimination (assumed to be a global process, governed by statistics) is local, based on some conspicuous local features (textons). It is shown that the top-down process of "shape (depth) from shading" does not affect stereopsis, and some of the models of machine vision are evaluated. The asymmetry effect of human texture discrimination is discussed, together with recent nonlinear spatial filter models and a novel extension of the texton theory that can cope with the asymmetry problem. This didactic review attempts to introduce the physicist to the field of psychobiology and its problems-including metascientific problems of brain research, problems of scientific creativity, the state of artificial intelligence research (including connectionist neural networks) aimed at modeling brain activity, and the fundamental role of focal attention in mental events.

  10. 7 Length-weight relationship

    African Journals Online (AJOL)

    Administrator

    Length-weight measurements were taken from well-preserved fish specimens from which stomachs were extracted for the analysis of the food contents, using frequency of occurrence, numerical and gravimetric methods, as well as index of relative importance. The length-frequency analysis showed a size distribution with a ...

  11. A novel method for patient exit and entrance dose prediction based on water equivalent path length measured with an amorphous silicon electronic portal imaging device

    International Nuclear Information System (INIS)

    Kavuma, Awusi; Glegg, Martin; Metwaly, Mohamed; Currie, Garry; Elliott, Alex

    2010-01-01

    In vivo dosimetry is one of the quality assurance tools used in radiotherapy to monitor the dose delivered to the patient. Electronic portal imaging device (EPID) images for a set of solid water phantoms of varying thicknesses were acquired and the data fitted onto a quadratic equation, which relates the reduction in photon beam intensity to the attenuation coefficient and material thickness at a reference condition. The quadratic model is used to convert the measured grey scale value into water equivalent path length (EPL) at each pixel for any material imaged by the detector. For any other non-reference conditions, scatter, field size and MU variation effects on the image were corrected by relative measurements using an ionization chamber and an EPID. The 2D EPL is linked to the percentage exit dose table, for different thicknesses and field sizes, thereby converting the plane pixel values at each point into a 2D dose map. The off-axis ratio is corrected using envelope and boundary profiles generated from the treatment planning system (TPS). The method requires field size, monitor unit and source-to-surface distance (SSD) as clinical input parameters to predict the exit dose, which is then used to determine the entrance dose. The measured pixel dose maps were compared with calculated doses from TPS for both entrance and exit depth of phantom. The gamma index at 3% dose difference (DD) and 3 mm distance to agreement (DTA) resulted in an average of 97% passing for the square fields of 5, 10, 15 and 20 cm. The exit dose EPID dose distributions predicted by the algorithm were in better agreement with TPS-calculated doses than phantom entrance dose distributions.

  12. Uniqueness in the determination of vibration sources in rectangular Germain–Lagrange plates using displacement measurements over line segments with arbitrary small length

    International Nuclear Information System (INIS)

    Kawano, Alexandre

    2013-01-01

    The theme of this work is related to the field of vibration and source detection, which is important in naval, aerospace and civil engineering industries. The detection of unexpected vibration sources, in general, signals malfunctioning, or even an undesired presence in the case of defense systems. The focus will be on thin plates, which are among the basic building blocks of large complex structures. Here, we consider loads acting on a rectangular plate R of the product form g(t)Q(x), where the function of time g has a continuous first derivative and the spatial load distribution Q is a square-integrable function over R. We prove that the observation of the displacement of a line segment with arbitrary length parallel to one of the sides of the plate is enough for the determination of Q, provided that the interval of time is long enough. We also prove that the normal derivative along a side of the rectangle measured for an arbitrarily small interval of time is sufficient to determine the spatial load distribution Q. The method used to obtain the results is based on the series decomposition of the dynamic response and an analysis of the almost periodic distribution that arises from it. (paper)

  13. Comparing linkage designs based on land facets to linkage designs based on focal species.

    Science.gov (United States)

    Brost, Brian M; Beier, Paul

    2012-01-01

    Least-cost modeling for focal species is the most widely used method for designing conservation corridors and linkages. However, these designs depend on today's land covers, which will be altered by climate change. We recently proposed an alternative approach based on land facets (recurring landscape units of relatively uniform topography and soils). The rationale is that corridors with high continuity of individual land facets will facilitate movement of species associated with each facet today and in the future. Conservation practitioners might like to know whether a linkage design based on land facets is likely to provide continuity of modeled breeding habitat for species needing connectivity today, and whether a linkage for focal species provides continuity and interspersion of land facets. To address these questions, we compared linkages designed for focal species and land facets in three landscapes in Arizona, USA. We used two variables to measure linkage utility, namely distances between patches of modeled breeding habitat for 5-16 focal species in each linkage, and resistance profiles for focal species and land facets between patches connected by the linkage. Compared to focal species designs, linkage designs based on land facets provided as much or more modeled habitat connectivity for 25 of 28 species-landscape combinations, failing only for the three species with the most narrowly distributed habitat. Compared to land facets designs, focal species linkages provided lower connectivity for about half the land facets in two landscapes. In areas where a focal species approach to linkage design is not possible, our results suggest that conservation practitioners may be able to implement a land facets approach with some confidence that the linkage design would serve most potential focal species. In areas where focal species designs are possible, we recommend using the land facet approach to complement, rather than replace, focal species approaches.

  14. Focal pancreatic enlargement: differentiation between pancreatic adenocarcinoma and focal pancreatitis on CT and ERCP

    International Nuclear Information System (INIS)

    Kim, Eun Kyung; Kim, Ki Whang; Lee, Jong Tae; Kim, Hee Soo; Yoo, Hyung Sik; Yu, Jeong Sik; Yoon, Sang Wook

    1995-01-01

    To differentiate the pancreatic adenocarcinoma from focal pancreatitis on CT and ERCP in cases of focal pancreatic enlargement. We analysed CT findings of 66 patients of pancreatic adenocarcinoma (n = 45) or focal pancreatitis (n = 21) with respect to size, density, calcification, pancreatic or biliary duct dilatation, fat plane obliteration around the vessels, direction of retroperitoneal extension, lymphadenopathy, pseudocyst formation and atrophy of pancreas. ERCP available in 48 patients were analysed in respect to morphologic appearance of CBD and pancreatic duct, and distance between the two ducts. The patients in focal pancreatitis were younger with more common history of alcohol drinking. There was no statistical difference in calcifications of the mass (18% in the adenocarcinoma, 33% in the focal pancreatitis), but a tendency of denser, larger number of calcifications was noted in focal pancreatitis. The finding of fat plane obliteration around the vessels were more common in pancreatic adenocarcinoma, and fascial thickenings were more prominent in focal pancreatitis, although not statistically significant. On ERCP, there were no differential points of CBD, pancreatic duct morphology, but distance between the two ducts at the lesion center was more wider in focal pancreatitis. Differentiating focal pancreatitis from pancreatic adenocarcinoma is difficult. However, we should consider the possibility of focal pancreatitis in cases of patients with young age, having alcoholic history in association with CT findings of large numbers of and dense calcifications, and ERCP findings of prominent separation of two duct at the lesion center

  15. Focal pancreatic enlargement: differentiation between pancreatic adenocarcinoma and focal pancreatitis on CT and ERCP

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Kyung; Kim, Ki Whang; Lee, Jong Tae; Kim, Hee Soo; Yoo, Hyung Sik; Yu, Jeong Sik; Yoon, Sang Wook [Yonsei University, College of Medicine, Seoul (Korea, Republic of)

    1995-10-15

    To differentiate the pancreatic adenocarcinoma from focal pancreatitis on CT and ERCP in cases of focal pancreatic enlargement. We analysed CT findings of 66 patients of pancreatic adenocarcinoma (n = 45) or focal pancreatitis (n = 21) with respect to size, density, calcification, pancreatic or biliary duct dilatation, fat plane obliteration around the vessels, direction of retroperitoneal extension, lymphadenopathy, pseudocyst formation and atrophy of pancreas. ERCP available in 48 patients were analysed in respect to morphologic appearance of CBD and pancreatic duct, and distance between the two ducts. The patients in focal pancreatitis were younger with more common history of alcohol drinking. There was no statistical difference in calcifications of the mass (18% in the adenocarcinoma, 33% in the focal pancreatitis), but a tendency of denser, larger number of calcifications was noted in focal pancreatitis. The finding of fat plane obliteration around the vessels were more common in pancreatic adenocarcinoma, and fascial thickenings were more prominent in focal pancreatitis, although not statistically significant. On ERCP, there were no differential points of CBD, pancreatic duct morphology, but distance between the two ducts at the lesion center was more wider in focal pancreatitis. Differentiating focal pancreatitis from pancreatic adenocarcinoma is difficult. However, we should consider the possibility of focal pancreatitis in cases of patients with young age, having alcoholic history in association with CT findings of large numbers of and dense calcifications, and ERCP findings of prominent separation of two duct at the lesion center.

  16. Decompression of tension pneumothoraces in Asian trauma patients: greater success with lateral approach and longer catheter lengths based on computed tomography chest wall measurements.

    Science.gov (United States)

    Goh, S; Xu, W R; Teo, L T

    2017-10-03

    Our study aims to compare the anterior and lateral approaches for needle thoracostomy (NT) and determine the adequacy of catheter lengths used for NT in Asian trauma patients based on computed tomography chest wall measurements. A retrospective review of chest computed tomography scans of 583 Singaporean trauma patients during period of 2011-2015 was conducted. Four measurements of chest wall thickness (CWT) were taken at the second intercostal space, midclavicular line and fifth intercostal space, midaxillary line bilaterally. Measurements were from the superficial skin layer of the chest wall to the pleural space. Successful NT was defined radiologically as CWT ≤ 5 cm. There were 593 eligible subjects. Mean age was 49.1 years (49.1 ± 21.0). Majority were males (77.0%) and Chinese (70.2%). Mean CWT for the anterior approach was 4.04 cm (CI 3.19-4.68) on the left and 3.92 cm (CI 3.17-4.63) on the right. Mean CWT for the lateral approach was 3.52 cm (CI 2.52-4.36) on the left, and 3.62 cm (CI 3.65-4.48) on the right. Mean CWT was shorter in the lateral approach by 0.52 cm on the left and 0.30 cm on the right (p = 0.001). With a 5.0 cm catheter in the anterior approach, 925 out of 1186 sites (78.8%) will have adequate NT as compared to 98.2% with a 7.0 cm catheter. Similarly, in the lateral approach 1046 out of 1186 (88.2%) will have adequate NT as compared to 98.5% with a 7.0 cm catheter. Obese subjects had significantly higher mean CWT in both approaches (p = 0.001). There was moderate correlation between BMI and CWT in the anterior approach, r 2  = 0.529 as compared to the lateral approach, r 2  = 0.244. Needle decompression using the lateral approach or a longer catheter is more likely to succeed in Asian trauma patients. A high BMI is an independent predictor of failure of NT, especially for the anterior as compared to lateral approach.

  17. Large Format Uncooled Focal Plane Array Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Uncooled focal plane arrays have improved dramatically and array sizes of 320x240 elements in a 50-?m pitch are commercially available at affordable cost. Black...

  18. Focal adhesions and cell-matrix interactions

    DEFF Research Database (Denmark)

    Woods, A; Couchman, J R

    1988-01-01

    Focal adhesions are areas of cell surfaces where specializations of cytoskeletal, membrane and extracellular components combine to produce stable cell-matrix interactions. The morphology of these adhesions and the components identified in them are discussed together with possible mechanisms...

  19. Strong reducing of the laser focal volume

    CSIR Research Space (South Africa)

    Godin, T

    2011-08-01

    Full Text Available Many applications of lasers seek nowadays for focal spots whose corresponding volume is getting smaller and smaller in order to ensure high spatial resolution. This problem, studied by many research groups around the world, is the core...

  20. Focal Cortical Hypometabolism and Infantile Spasms

    Directory of Open Access Journals (Sweden)

    J Gordon Millichap

    2002-06-01

    Full Text Available The occurrence and prognostic significance of focal defects in cerebral cortical glucose metabolism were evaluated in infants with newly diagnosed symptomatic and cryptogenic infantile spasms examined at Turku and Helsinki Universities, Finland.

  1. Determination of the size of X-ray tube focal spots: direct digitalization vs optical evaluation

    International Nuclear Information System (INIS)

    Furquim, Tania A.C.; Yanikian, Denise; Costa, Paulo R.

    1996-01-01

    A comparative study between standard techniques for evaluation of X-ray tubes focal spots and a newer one which uses digital resources for image acquisition is presented. Results from measurements by using both methods are presented

  2. discouraged by queue length

    Directory of Open Access Journals (Sweden)

    P. R. Parthasarathy

    2001-01-01

    Full Text Available The transient solution is obtained analytically using continued fractions for a state-dependent birth-death queue in which potential customers are discouraged by the queue length. This queueing system is then compared with the well-known infinite server queueing system which has the same steady state solution as the model under consideration, whereas their transient solutions are different. A natural measure of speed of convergence of the mean number in the system to its stationarity is also computed.

  3. Focal lesions in the central nervous system

    International Nuclear Information System (INIS)

    Fabrikant, J.I.; Budinger, T.F.; Tobias, C.A.; Born, J.L.

    1980-01-01

    This report reviews the animal and human studies currently in progress at LBL with heavy-ion beams to induce focal lesions in the central nervous system, and discusses the potential future prospects of fundamental and applied brain research with heavy-ion beams. Methods are being developed for producing discrete focal lesions in the central nervous system using the Bragg ionization peak to investigate nerve pathways and neuroendocrine responses, and for treating pathological disorders of the brain

  4. Treatment planning for prostate focal laser ablation in the face of needle placement uncertainty

    Energy Technology Data Exchange (ETDEWEB)

    Cepek, Jeremy, E-mail: jcepek@robarts.ca; Fenster, Aaron [Robarts Research Institute, London, Ontario N6A 5K8, Canada and Biomedical Engineering, The University of Western Ontario, London, Ontario N6A 5B9 (Canada); Lindner, Uri; Trachtenberg, John [Department of Surgical Oncology, Division of Urology, University Health Network, Toronto, Ontario M5G 2C4 (Canada); Davidson, Sean R. H. [Ontario Cancer Institute, University Health Network, Toronto, Ontario M5G 2M9 (Canada); Haider, Masoom A. [Department of Medical Imaging, Sunnybrook Health Sciences Center, Toronto, Ontario M4N 3M5, Canada and Department of Medical Imaging, University of Toronto, Toronto, Ontario M5S 2J7 (Canada); Ghai, Sangeet [Department of Medical Imaging, University Health Network, Toronto, Ontario M5G 2M9 (Canada)

    2014-01-15

    Purpose: To study the effect of needle placement uncertainty on the expected probability of achieving complete focal target destruction in focal laser ablation (FLA) of prostate cancer. Methods: Using a simplified model of prostate cancer focal target, and focal laser ablation region shapes, Monte Carlo simulations of needle placement error were performed to estimate the probability of completely ablating a region of target tissue. Results: Graphs of the probability of complete focal target ablation are presented over clinically relevant ranges of focal target sizes and shapes, ablation region sizes, and levels of needle placement uncertainty. In addition, a table is provided for estimating the maximum target size that is treatable. The results predict that targets whose length is at least 5 mm smaller than the diameter of each ablation region can be confidently ablated using, at most, four laser fibers if the standard deviation in each component of needle placement error is less than 3 mm. However, targets larger than this (i.e., near to or exceeding the diameter of each ablation region) require more careful planning. This process is facilitated by using the table provided. Conclusions: The probability of completely ablating a focal target using FLA is sensitive to the level of needle placement uncertainty, especially as the target length approaches and becomes greater than the diameter of ablated tissue that each individual laser fiber can achieve. The results of this work can be used to help determine individual patient eligibility for prostate FLA, to guide the planning of prostate FLA, and to quantify the clinical benefit of using advanced systems for accurate needle delivery for this treatment modality.

  5. A Micro-Thermal Sensor for Focal Therapy Applications

    Science.gov (United States)

    Natesan, Harishankar; Hodges, Wyatt; Choi, Jeunghwan; Lubner, Sean; Dames, Chris; Bischof, John

    2016-02-01

    There is an urgent need for sensors deployed during focal therapies to inform treatment planning and in vivo monitoring in thin tissues. Specifically, the measurement of thermal properties, cooling surface contact, tissue thickness, blood flow and phase change with mm to sub mm accuracy are needed. As a proof of principle, we demonstrate that a micro-thermal sensor based on the supported “3ω” technique can achieve this in vitro under idealized conditions in 0.5 to 2 mm thick tissues relevant to cryoablation of the pulmonary vein (PV). To begin with “3ω” sensors were microfabricated onto flat glass as an idealization of a focal probe surface. The sensor was then used to make new measurements of ‘k’ (W/m.K) of porcine PV, esophagus, and phrenic nerve, all needed for PV cryoabalation treatment planning. Further, by modifying the sensor use from traditional to dynamic mode new measurements related to tissue vs. fluid (i.e. water) contact, fluid flow conditions, tissue thickness, and phase change were made. In summary, the in vitro idealized system data presented is promising and warrants future work to integrate and test supported “3ω” sensors on in vivo deployed focal therapy probe surfaces (i.e. balloons or catheters).

  6. A Micro-Thermal Sensor for Focal Therapy Applications.

    Science.gov (United States)

    Natesan, Harishankar; Hodges, Wyatt; Choi, Jeunghwan; Lubner, Sean; Dames, Chris; Bischof, John

    2016-02-26

    There is an urgent need for sensors deployed during focal therapies to inform treatment planning and in vivo monitoring in thin tissues. Specifically, the measurement of thermal properties, cooling surface contact, tissue thickness, blood flow and phase change with mm to sub mm accuracy are needed. As a proof of principle, we demonstrate that a micro-thermal sensor based on the supported "3ω" technique can achieve this in vitro under idealized conditions in 0.5 to 2 mm thick tissues relevant to cryoablation of the pulmonary vein (PV). To begin with "3ω" sensors were microfabricated onto flat glass as an idealization of a focal probe surface. The sensor was then used to make new measurements of 'k' (W/m.K) of porcine PV, esophagus, and phrenic nerve, all needed for PV cryoabalation treatment planning. Further, by modifying the sensor use from traditional to dynamic mode new measurements related to tissue vs. fluid (i.e. water) contact, fluid flow conditions, tissue thickness, and phase change were made. In summary, the in vitro idealized system data presented is promising and warrants future work to integrate and test supported "3ω" sensors on in vivo deployed focal therapy probe surfaces (i.e. balloons or catheters).

  7. Focal nodular hyperplasia in a child with hemihypertrophy and multiple cutaneous vascular malformations.

    Science.gov (United States)

    Al-Attar, M; Verma, R; Shannon, R S; McKeever, P A; Rickett, A

    2004-03-01

    A case of focal nodular hyperplasia of the liver occurring in a 9-year-old girl with musculoskeletal hemihypertrophy and multiple cutaneous capillary haemangiomata is described. The child presented because of limb length discrepancy and was found to have a large mass in the liver. Imaging showed a mass of similar characteristics to normal liver tissue. Prominent vascular supply to the liver was also seen. We present this case to emphasize the important diagnosis of focal nodular hyperplasia, which may occur in syndromic form in children with typical cutaneous and skeletal manifestations.

  8. Calculation of exit dose for conformal and dynamically‐wedged fields, based on water‐equivalent path length measured with an amorphous silicon electronic portal imaging device

    Science.gov (United States)

    Glegg, Martin; Metwaly, Mohamed; Currie, Garry; Elliott, Alex

    2011-01-01

    In this study, we use the quadratic calibration method (QCM), in which an EPID image is converted into a matrix of equivalent path lengths (EPLs) and, therefore, exit doses, so as to model doses in conformal and enhanced dynamic wedge (EDW) fields. The QCM involves acquiring series of EPID images at a reference field size for different thicknesses of homogeneous solid water blocks. From these, a set of coefficients is established that is used to compute the EPL of any other irradiated material. To determine the EPL, the irradiated area must be known in order to establish the appropriate scatter correction. A method was devised for the automatic calculation of areas from the EPID image that facilitated the calculation of EPL for any field and exit dose. For EDW fields, the fitting coefficients were modified by utilizing the linac manufacturer's golden segmented treatment tables (GSTT) methodology and MU fraction model. The nonlinear response of the EPL with lower monitor units (MUs) was investigated and slight modification of the algorithm performed to account for this. The method permits 2D dose distributions at the exit of phantom or patient to be generated by relating the EPL with an appropriate depth dose table. The results indicate that the inclusion of MU correction improved the EPL determination. The irradiated field areas can be accurately determined from EPID images to within ± 1% uncertainty. Cross‐plane profiles and 2D dose distributions of EPID predicted doses were compared with those calculated with the Eclipse treatment planning system (TPS) and those measured directly with MapCHECK 2 device. Comparison of the 2D EPID dose maps to those from TPS and MapCHECK shows that more than 90% of all points passed the gamma index acceptance criteria of 3% dose difference and 3 mm distance to agreement (DTA), for both conformal and EDW study cases. We conclude that the EPID QCM is an accurate and convenient method for in vivo dosimetry and may, therefore

  9. Laser focal profiler based on forward scattering of a nanoparticle

    Science.gov (United States)

    Ota, Taisuke

    2018-03-01

    A laser focal intensity profiling method based on the forward scattering from a nanoparticle is demonstrated for in situ measurements using a laser focusing system with six microscope objective lenses with different numerical apertures ranging from 0.15 to 1.4. The measured profiles showed Airy disc patterns although their rings showed some imperfections due to aberrations and misalignment of the test system. The dipole radiation model revealed that the artefact of this method was much smaller than the influence of the deterioration in the experimental system; a condition where no artefact appears was predicted based on proper selection of measurement angles.

  10. Production of high energy, uniform focal profiles with the Nike laser

    Science.gov (United States)

    Lehecka, T.; Lehmberg, R. H.; Deniz, A. V.; Gerber, K. A.; Obenschain, S. P.; Pawley, C. J.; Pronko, M. S.; Sullivan, C. A.

    1995-02-01

    Nike, a KrF laser facility at the Naval Research Laboratory, is designed to produce high intensity, ultra-uniform focal profiles for experiments relating to direct drive inertial confinement fusion. We present measurements of focal profiles through the next-to-last amplifier, a 20 × 20 cm 2 aperture electron beam pumped amplifier capable of producing more than 120 J of output in a 120 ns pulse. Using echelon free induced spatial incoherence beam smoothing this system has produced focal profiles with less than 2% tilt and curvature and less than 2% rms variation from a flat top distribution.

  11. Diagnostic Performance and Additional Value of Elastosonography in Focal Breast Lesions: Statistical Correlation between Size-Dependant Strain Index Measurements, Multimodality-BI-RADS Score, and Histopathology in a Clinical Routine Setting

    Science.gov (United States)

    Bonel, Harald M.; Huber, Adrian; Christe, Andreas

    2014-01-01

    Objective. To evaluate the diagnostic benefit of real-time elastography (RTE) in clinical routine. Strain indices (SI) for benign and malignant tumors were assessed. Methods. 100 patients with 110 focal breast lesions were retrieved. Patients had mammography (MG), ultrasound (US), and, if necessary, MRI. RTE was conducted after ultrasound. Lesions were assessed with BI-RADS for mammography and ultrasound. Diagnosis was established with histology or follow-up. Results. SI for BI-RADS 2 was 1.71 ± 0.86. Higher SI (2.21 ± 1.96) was observed for BI-RADS 3 lesions. SI of BI-RADS 4 and 5 lesions were significantly higher (16.92 ± 20.89) and (19.54 ± 10.41). 31 malignant tumors exhibited an average SI of 16.13 ± 14.67; SI of benign lesions was 5.29 ± 11.87 (P value 3.8 for malignant disease. Sensitivity of sonography was 90.3% (specificity 78.5%). RTE showed a sensitivity of 87.1% (specificity 79.7%). Accuracy of all modalities combined was 96.8%. In BI-RADS 3 lesions RTE was able to detect all malignant lesions (sensitivity 100%, specificity 92.9%, and accuracy 93.9%). Conclusions. RTE increased sensitivity and specificity for breast cancer detection when used in combination with ultrasound. PMID:24967295

  12. Measurement of absolute light yield and determination of a lower limit for the light attenuation length for YAP:Ce crystal

    International Nuclear Information System (INIS)

    Del Guerra, A.; Domenico, G.D.; Zavattini, G.

    1996-01-01

    The aim of this work was to study the peak position of the photoabsorption peak as a function of the interaction distance from the photomultiplier window in order to get some information about the light attenuation length, internal reflectivity and absolute light yield for a 2 x 2 x 30 mm 3 YAP:Ce scintillator

  13. Prenatal sonographic diagnosis of focal musculoskeletal anomalies

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jung-Kyu; Cho, Jeong-Yeon; Choi, Jong-Sun [Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2003-12-15

    Focal musculoskeletal anomalies vary, and can manifest as part of a syndrome or be accompanied by numerous other conditions such as genetic disorders, karyotype abnormalities, central nervous system anomalies and other skeletal anomalies, lsolated focal musculoskeletal anomaly does, however, also occur; its early prenatal diagnosis is important in deciding prenatal care, and also helps in counseling parents about the postnatal effects of numerous possible associated anomalies. We have encountered 50 cases involving focal musculoskeletal anomalies, including total limb dysplasia [radial ray abnormality (n=3), mesomelic dysplasia (n=1)]; anomalies of the hand [polydactyly (n=8), syndactyly (n=3), ectrodactyly (n=1), clinodactyly (n=6), clenched hand (n=5)]; anomalies of the foot [clubfoot (n=10), rockerbottom foot (n=5), sandal gap deformity (n=1), curly toe (n=2)]; amniotic band syndrome (n=3); and anomalies of the focal spine [block vertebra (n=1), hemivertebra (n=1)]. Among these 50 cases, five [polydactyly (n=1), syndactyly (n=2) and curly toe (n=2) were confirmed by postnatal physical evaluation, two (focal spine anomalies) were diagnosed after postnatal radiologic examination, and the remaining 43 were proven at autopsy. For each condition, we describe the prenatal sonographic findings, and include a brief review.

  14. Prenatal sonographic diagnosis of focal musculoskeletal anomalies

    International Nuclear Information System (INIS)

    Ryu, Jung-Kyu; Cho, Jeong-Yeon; Choi, Jong-Sun

    2003-01-01

    Focal musculoskeletal anomalies vary, and can manifest as part of a syndrome or be accompanied by numerous other conditions such as genetic disorders, karyotype abnormalities, central nervous system anomalies and other skeletal anomalies, lsolated focal musculoskeletal anomaly does, however, also occur; its early prenatal diagnosis is important in deciding prenatal care, and also helps in counseling parents about the postnatal effects of numerous possible associated anomalies. We have encountered 50 cases involving focal musculoskeletal anomalies, including total limb dysplasia [radial ray abnormality (n=3), mesomelic dysplasia (n=1)]; anomalies of the hand [polydactyly (n=8), syndactyly (n=3), ectrodactyly (n=1), clinodactyly (n=6), clenched hand (n=5)]; anomalies of the foot [clubfoot (n=10), rockerbottom foot (n=5), sandal gap deformity (n=1), curly toe (n=2)]; amniotic band syndrome (n=3); and anomalies of the focal spine [block vertebra (n=1), hemivertebra (n=1)]. Among these 50 cases, five [polydactyly (n=1), syndactyly (n=2) and curly toe (n=2) were confirmed by postnatal physical evaluation, two (focal spine anomalies) were diagnosed after postnatal radiologic examination, and the remaining 43 were proven at autopsy. For each condition, we describe the prenatal sonographic findings, and include a brief review

  15. Focal fatty infiltra- tion and focal fatty sparing of the liver

    African Journals Online (AJOL)

    Enrique

    Introduction. Focal fatty infiltration of the liver is caused by focal deposition of intracel- lular fat within hepatocytes. Although more commonly detected in adults it has also been described in children.1. The most common cause is alcohol abuse, although diabetes, obesity, cer- tain drugs, toxins, protein energy mal- nutrition ...

  16. Characteristics of focal mechanisms in Chile subduction

    Directory of Open Access Journals (Sweden)

    Wang Xiaoshan

    2012-08-01

    Full Text Available We use the Centroid Moment Tensor (CMT solution of the earthquakes occurred in Chile subduction to analyze the characteristics of focal mechanisms. We define the angle between P, B, and T axes of focal mechanisms and three stress axes of tectonic stress field as the consistency parameter, to research the dynamic changes of focal mechanism pattern in earthquake preparation area before the 2010 Maule, Chile earthquake. The result shows that the consistency parameter decreases before the earthquake, and the area of the lower consistent parameter visually coincides with the distribution of aftershocks. This phenomenon is similar to the Load-Unload Response Ratio (LURR decreases prior to the occurrence of macro-fracture happened in the acoustic emission experiments involving large rock specimens under tri-axial stress.

  17. Comparison of Birth-and Conception-Based Definitions of Postnatal Age in Developmental and Reproductive Rodent Toxicity Studies: lnfluence of Gestation Length on Measurements of Offspring Body Weight and Puberty in Controls

    Science.gov (United States)

    Most laboratories conducting developmental and reproductive toxicity studies in rodents assign age by defining postnatal day (PND) 0 or 1 as the day of birth (DOB); i.e., gestation length affects PND and the timing of postnatal measurements. Some laboratories, however, define age...

  18. First-trimester screening in pregnancies conceived by assisted reproductive technology: significance of gestational dating by oocyte retrieval or sonographic measurement of crown-rump length

    DEFF Research Database (Denmark)

    Gjerris, A.C.; Loft, A.; Pinborg, A.

    2008-01-01

    OBJECTIVES: To evaluate, in pregnancies conceived by assisted reproductive technology, whether determination of gestational age (GA) by date of oocyte aspiration (DOA) or crown-rump length (CRL) at first-trimester screening influences the distribution of serum and sonographic markers or the perfo......OBJECTIVES: To evaluate, in pregnancies conceived by assisted reproductive technology, whether determination of gestational age (GA) by date of oocyte aspiration (DOA) or crown-rump length (CRL) at first-trimester screening influences the distribution of serum and sonographic markers......). Weight-corrected log multiples of the median (MoM) marker distributions specific for IVF pregnancy were established using multiple log regression and compared for DOA- and CRL-based GA calculation. RESULTS: GA determined by CRL was significantly larger, albeit slightly, than was GA determined by DOA...

  19. Autofocusing Airy beam STED microscopy with long focal distance

    Science.gov (United States)

    Hu, Di; Liang, Yao; Chen, Yin; Chen, Zan Hui; Huang, Xu Guang

    2017-12-01

    Stimulated emission depletion (STED) is a very important technique in super-resolution microscopy. Until now, while autofocusing Airy beam (AAB) has been an attractive theme for both theoretical and applied researches, there are almost no report on AABs being used in STED microscopy. In this paper, we propose a novel STED microscopy based on AABs. A radially symmetric 3/2 phase plate is involved to simultaneously generate autofocusing excitation- and depletion-Airy beams. Remarkably, the AAB can auto-focus to a wavelength-scale spot with a long focal depth (several millimeters): on the contrary, the working distance of a conventional high numerical aperture (NA) objective is usually very short (about 200 μm). Our calculations indicate that the AAB based STED microscopy can achieve a super-resolution spot with FWHM of 58 nm while the focal length is 4.638 mm. Moreover, with properties of non-diffracting and self-healing, the Airy beam could enable a reduction of the scattering distortion induced by the specimens and has a great potential in imaging thick specimens.

  20. Recurrent Focal myositis: a rare inflammatory myopathy.

    Science.gov (United States)

    Teixeira, F; Peixoto, D; Costa, J A; Bogas, M; Taipa, R; Melo Pires, M; Afonso, C; Araújo, D

    2014-01-01

    Focal myositis is an acute and localized muscle inflammation of unknown aetiology. The clinical diagnosis is often difficult to obtain, since it can be confused with infections, vascular thrombosis or muscle tumours such as sarcomas. This leads to a significant delay in the diagnosis, resulting in the administration of inappropriate and potentially harmful treatments.  We report here a case of recurrent focal myositis in a woman where the diagnosis was only obtained after 6 years, despite multiple hospital admissions. This case reinforces the importance of clinical knowledge and experience to tackle challenging medical scenarios.

  1. Focal splenic masses of the extramedullary hematopoiesis

    International Nuclear Information System (INIS)

    Incedayi, M.; Sivrioglu, A.

    2012-01-01

    Full text: Extramedullary hematopoiesis arises from pleuripotential stem cells distributed throughout the body. It is most common in patients with congenital hemolytic anemia, such as thalassemia, sickle cell anemia and hereditary spherocytosis as a response to ineffective red blood cell formation. Although microscopic foci of Extramedullary hematopoiesis are commonly seen in the spleen and liver parenchyma, focal mass-like lesion of extramedullary hematopoiesis in the liver and spleen are rare. We report a case of intrasplenic focal extramedullary hematopoiesis lesions and the imaging features of extramedullary hematopoiesis on computed tomography and magnetic resonance imaging. Extramedullary hematopoiesis should always be considered as a diagnosis in a patient with a known hematological disorder

  2. Actinic Granuloma with Focal Segmental Glomerulosclerosis

    Directory of Open Access Journals (Sweden)

    Ruedee Phasukthaworn

    2016-02-01

    Full Text Available Actinic granuloma is an uncommon granulomatous disease, characterized by annular erythematous plaque with central clearing predominately located on sun-damaged skin. The pathogenesis is not well understood, ultraviolet radiation is recognized as precipitating factor. We report a case of a 52-year-old woman who presented with asymptomatic annular erythematous plaques on the forehead and both cheeks persisting for 2 years. The clinical presentation and histopathologic findings support the diagnosis of actinic granuloma. During that period of time, she also developed focal segmental glomerulosclerosis. The association between actinic granuloma and focal segmental glomerulosclerosis needs to be clarified by further studies.

  3. CdTe Focal Plane Detector for Hard X-Ray Focusing Optics

    Science.gov (United States)

    Seller, Paul; Wilson, Matthew D.; Veale, Matthew C.; Schneider, Andreas; Gaskin, Jessica; Wilson-Hodge, Colleen; Christe, Steven; Shih, Albert Y.; Inglis, Andrew; Panessa, Marco

    2015-01-01

    The demand for higher resolution x-ray optics (a few arcseconds or better) in the areas of astrophysics and solar science has, in turn, driven the development of complementary detectors. These detectors should have fine pixels, necessary to appropriately oversample the optics at a given focal length, and an energy response also matched to that of the optics. Rutherford Appleton Laboratory have developed a 3-side buttable, 20 millimeter x 20 millimeter CdTe-based detector with 250 micrometer square pixels (80 x 80 pixels) which achieves 1 kiloelectronvolt FWHM (Full-Width Half-Maximum) @ 60 kiloelectronvolts and gives full spectroscopy between 5 kiloelectronvolts and 200 kiloelectronvolts. An added advantage of these detectors is that they have a full-frame readout rate of 10 kilohertz. Working with NASA Goddard Space Flight Center and Marshall Space Flight Center, 4 of these 1 millimeter-thick CdTe detectors are tiled into a 2 x 2 array for use at the focal plane of a balloon-borne hard-x-ray telescope, and a similar configuration could be suitable for astrophysics and solar space-based missions. This effort encompasses the fabrication and testing of flight-suitable front-end electronics and calibration of the assembled detector arrays. We explain the operation of the pixelated ASIC readout and measurements, front-end electronics development, preliminary X-ray imaging and spectral performance, and plans for full calibration of the detector assemblies. Work done in conjunction with the NASA Centers is funded through the NASA Science Mission Directorate Astrophysics Research and Analysis Program.

  4. Magnetoencephalography (MEG) predicts focal epileptogenicity in cavernomas

    Science.gov (United States)

    Stefan, H; Scheler, G; Hummel, C; Walter, J; Romstock, J; Buchfelder, M; Blumcke, I

    2004-01-01

    Objective: The aim of this study was to identify the irritative epileptic zone in patients with cavernomas by means of magnetoencephalography (MEG). Method: Among 82 patients operated for epilepsy, whose presurgical evaluation had included MEG, histological assessment of the tissue removed had confirmed cavernomas in eight. These eight patients had epilepsy since 18.6 (SD 12.7) years on average. The monitoring lasted about 2.1 (SD 1.3) hours and a median 20.9 (SD 14.3) spikes per hour were recorded. Spontaneous brain activity was recorded by means of a 74 channel dual unit MEG system (Magnes II, 4-D Neuroimaging) with simultaneous EEG recording (31 scalp electrodes). Spike analysis was performed using different source (moving dipole, current density reconstruction) and head models (spherical shells, BEM). Co-registration of neurophysiological and imaging data (MRI) was based upon anatomical landmarks. Results: In 6/8 patients co-localisation from the cavernoma and epileptic zone was found. In two patients the focus was localised in the parieto-occipital lobe, in three patients in the frontal lobe and in three patients in the temporal lobe. In one case of temporal and one case of frontal lobe focus localisation there was no spatial relationship to the cavernoma. Conclusion: In cases of focal seizures due to a single cavernoma, MEG may precisely delineate the epileptogenic tissue bordering the lesion. In patients with multiple cavernomas or dual pathology, MSI may reveal the complexity of the case, and contribute to the decision about further invasive diagnostics and more sophisticated therapeutic measures. MEG is a promising method for prediction of the epileptic zone in cavernoma related epilepsies, and thus it can contribute to decision making about and planning of epilepsy surgery. PMID:15314122

  5. Evaluation of focused ultrasound algorithms: Issues for reducing pre-focal heating and treatment time.

    Science.gov (United States)

    Yiannakou, Marinos; Trimikliniotis, Michael; Yiallouras, Christos; Damianou, Christakis

    2016-02-01

    Due to the heating in the pre-focal field the delay between successive movements in high intensity focused ultrasound (HIFU) are sometimes as long as 60s, resulting to treatment time in the order of 2-3h. Because there is generally a requirement to reduce treatment time, we were motivated to explore alternative transducer motion algorithms in order to reduce pre-focal heating and treatment time. A 1 MHz single element transducer with 4 cm diameter and 10 cm focal length was used. A simulation model was developed that estimates the temperature, thermal dose and lesion development in the pre-focal field. The simulated temperature history that was combined with the motion algorithms produced thermal maps in the pre-focal region. Polyacrylimde gel phantom was used to evaluate the induced pre-focal heating for each motion algorithm used, and also was used to assess the accuracy of the simulation model. Three out of the six algorithms having successive steps close to each other, exhibited severe heating in the pre-focal field. Minimal heating was produced with the algorithms having successive steps apart from each other (square, square spiral and random). The last three algorithms were improved further (with small cost in time), thus eliminating completely the pre-focal heating and reducing substantially the treatment time as compared to traditional algorithms. Out of the six algorithms, 3 were successful in eliminating the pre-focal heating completely. Because these 3 algorithms required no delay between successive movements (except in the last part of the motion), the treatment time was reduced by 93%. Therefore, it will be possible in the future, to achieve treatment time of focused ultrasound therapies shorter than 30 min. The rate of ablated volume achieved with one of the proposed algorithms was 71 cm(3)/h. The intention of this pilot study was to demonstrate that the navigation algorithms play the most important role in reducing pre-focal heating. By evaluating in

  6. Infrared MUSIC from Z technology focal planes

    International Nuclear Information System (INIS)

    Waters, C.R.; Sommese, A.; Johnston, D.; Landau, H.

    1989-01-01

    Presented is the Multiple Signal Classification (MUSIC) algorithm which uses the high frequency differences in sensed time signals to discriminate, count, and accurately locate closely spaced targets. Z technology focal planes allow the implementation of this algorithm and the trade-off between finer spatial resolution systems and systems with coarser resolution but higher sampling rates

  7. Ketogenic Diet for Epilepsy and Focal Malformation

    Directory of Open Access Journals (Sweden)

    J Gordon Millichap

    2008-09-01

    Full Text Available The efficacy and long-term treatment outcome of a classic ketogenic diet (KD addon treatment (4:1 lipid/nonlipid ratio, without initial fasting and fluid restriction were evaluated retrospectively in 47 children with intractable epilepsy and focal malformation of cortical development, in a study at Severance Children’s and Sanggye Park Hospitals, Seoul, Korea.

  8. Sensory-motor integration in focal dystonia.

    Science.gov (United States)

    Avanzino, Laura; Tinazzi, Michele; Ionta, Silvio; Fiorio, Mirta

    2015-12-01

    Traditional definitions of focal dystonia point to its motor component, mainly affecting planning and execution of voluntary movements. However, focal dystonia is tightly linked also to sensory dysfunction. Accurate motor control requires an optimal processing of afferent inputs from different sensory systems, in particular visual and somatosensory (e.g., touch and proprioception). Several experimental studies indicate that sensory-motor integration - the process through which sensory information is used to plan, execute, and monitor movements - is impaired in focal dystonia. The neural degenerations associated with these alterations affect not only the basal ganglia-thalamic-frontal cortex loop, but also the parietal cortex and cerebellum. The present review outlines the experimental studies describing impaired sensory-motor integration in focal dystonia, establishes their relationship with changes in specific neural mechanisms, and provides new insight towards the implementation of novel intervention protocols. Based on the reviewed state-of-the-art evidence, the theoretical framework summarized in the present article will not only result in a better understanding of the pathophysiology of dystonia, but it will also lead to the development of new rehabilitation strategies. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Florid periosteal reaction and focal fibrocartilaginous dysplasia

    International Nuclear Information System (INIS)

    Nakase, T.; Yasui, Natsuo; Araki, Nobuhito; Tanaka, Makoto; Yoshikawa, Hideki; Ochi, Takahiro; Kuratsu, Shigeyuki

    1998-01-01

    Focal fibrocartilaginous dysplasia (FFCD) is a rare condition causing tibia vara in childhood. It is characterized by progressive tibia vara in young children with a characteristic radiographic lesion. This paper is thought to be the first to describe FFCD exhibiting florid periosteal reaction at the time of presentation with a subtle faint osteolytic lesion in the diametaphysis of the proximal tibia. (orig.)

  10. Focal adhesions and assessment of cytotoxicity

    NARCIS (Netherlands)

    van Kooten, TG; Klein, CL; Wagner, M; Kirkpatrick, CJ

    Focal adhesions are highly ordered assemblies of transmembrane receptors, extracellular matrix proteins, and a large number of cytoplasmic proteins, including structural proteins, as well as tyrosine kinases, phosphatases, and their substrates. They are now accepted as a prime component of signal

  11. Measurement of product of solid state laser materials by an ...

    Indian Academy of Sciences (India)

    The cavity mode area is estimated by measuring the thermal lens focal length at the threshold and the average pump area is measured by Gaussian fit to the intensity profiles of the pump beam. The value of product of Nd:YVO4 crystal obtained by this method is within 10% of the reported values. The advantage of this ...

  12. Mature clustered, regularly interspaced, short palindromic repeats RNA (crRNA) length is measured by a ruler mechanism anchored at the precursor processing site.

    Science.gov (United States)

    Hatoum-Aslan, Asma; Maniv, Inbal; Marraffini, Luciano A

    2011-12-27

    Precise RNA processing is fundamental to all small RNA-mediated interference pathways. In prokaryotes, clustered, regularly interspaced, short palindromic repeats (CRISPR) loci encode small CRISPR RNAs (crRNAs) that protect against invasive genetic elements by antisense targeting. CRISPR loci are transcribed as a long precursor that is cleaved within repeat sequences by CRISPR-associated (Cas) proteins. In many organisms, this primary processing generates crRNA intermediates that are subject to additional nucleolytic trimming to render mature crRNAs of specific lengths. The molecular mechanisms underlying this maturation event remain poorly understood. Here, we defined the genetic requirements for crRNA primary processing and maturation in Staphylococcus epidermidis. We show that changes in the position of the primary processing site result in extended or diminished maturation to generate mature crRNAs of constant length. These results indicate that crRNA maturation occurs by a ruler mechanism anchored at the primary processing site. We also show that maturation is mediated by specific cas genes distinct from those genes involved in primary processing, showing that this event is directed by CRISPR/Cas loci.

  13. The effects of surgical lengthening of hamstring muscles in children with cerebral palsy--the consequences of pre-operative muscle length measurement.

    Science.gov (United States)

    Laracca, Ettore; Stewart, Caroline; Postans, Neil; Roberts, Andrew

    2014-03-01

    Children with cerebral palsy often undergo multiple orthopaedic surgical procedures in a single episode. Evidence of the effectiveness of individual components within the overall package is sparse. The introduction of musculoskeletal modelling in Oswestry has led to a more conservative management approach being taken with hamstring muscles for children walking in a degree of crouch. Muscles which were shown to be of at least normal length at initial contact were not surgically lengthened, as would have been the case previously. A retrospective review of 30 such patients was therefore possible, comparing 15 patients treated before the policy change who had their hamstrings lengthened with 15 treated after who did not. All patients had pre and post operative gait assessments and significant changes were observed for each group separately and for the two groups when compared. The comparison revealed that preserving the hamstrings does tend to reduce, and therefore normalize, the dynamic muscle length. Examination of the two patient groups separately, however, reveals a more complex picture with more global gait improvements seen when the hamstrings were lengthened. No absolute recommendation can be made to inform the clinical management of all children with normal to long hamstring muscles during gait. The final decision of whether to include a hamstring lengthening will need to take into account the characteristics of the individual child. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Endodontic Working Length Measurement Using Cone-beam Computed Tomographic Images Obtained at Different Voxel Sizes and Field of Views, Periapical Radiography, and Apex Locator: A Comparative Ex Vivo Study.

    Science.gov (United States)

    Yılmaz, Funda; Kamburoğlu, Kıvanç; Şenel, Buğra

    2017-01-01

    The aim of this study was to evaluate the accuracy of working length determination by using an electronic apex locator, periapical radiography, and cone-beam computed tomographic (CBCT) imaging obtained at different voxel sizes and field of views (FOVs) in extracted human teeth. Thirty extracted human mandibular premolar teeth were used. The electronic working length measurements were performed by using an electronic apex locator (Root ZX; J Morita Corp, Kyoto, Japan). Five different image sets were obtained as follows: (1) CBCT imaging: 40 × 40 mm FOV, 0.080 mm 3 (FOV 40 ); (2) CBCT imaging: 60 × 60 mm FOV, 0.125 mm 3 (FOV 60 ); (3) CBCT imaging: 80 × 80 mm FOV, 0.160 mm 3 (FOV 80 ); (4) CBCT imaging: 100 × 100 mm FOV, 0.250 mm 3 (FOV 100 ); and (5) periapical digital radiography. Direct measurements performed with an electronic digital caliper were considered as the gold standard and compared with the electronic apex locator, CBCT, and periapical image measurements. Data were analyzed using a 2-way analysis of variance test. Significance level was set at P  .05 and the Gage R&R value was 30%). There were significant differences in the methods in terms of mean differences from the gold standard (P < .05). This study showed that available CBCT scans with different FOVs can be used for working length measurement. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  15. Direct measuring of single-cycle mid-IR light bullets path length in LiF by the laser coloration method

    Science.gov (United States)

    Chekalin, Sergey; Kompanets, Victor; Kuznetsov, Andrey; Dormidonov, Alexander; Kandidov, Valerii

    2017-10-01

    A colour-centre structure formed in a LiF crystal under filamentation of a femtosecond mid-IR laser pulse with a power slightly exceeding the critical power for self-focusing has been experimentally and theoretically investigated. A single-cycle light bullet was recorded for the first time by observation of strictly periodic oscillations for the density of the color centers induced in an isotropic LiF crystal under filamentation of a laser beam with a wavelength tuned in the range from 2600 to 3900 nm, which is due to the periodic change in the light field amplitude in the light bullet formed under filamentation under propagation in dispersive medium. The light bullet path length was not more than one millimeter.

  16. Direct measuring of single-cycle mid-IR light bullets path length in LiF by the laser coloration method

    Directory of Open Access Journals (Sweden)

    Chekalin Sergey

    2017-01-01

    Full Text Available A colour-centre structure formed in a LiF crystal under filamentation of a femtosecond mid-IR laser pulse with a power slightly exceeding the critical power for self-focusing has been experimentally and theoretically investigated. A single-cycle light bullet was recorded for the first time by observation of strictly periodic oscillations for the density of the color centers induced in an isotropic LiF crystal under filamentation of a laser beam with a wavelength tuned in the range from 2600 to 3900 nm, which is due to the periodic change in the light field amplitude in the light bullet formed under filamentation under propagation in dispersive medium. The light bullet path length was not more than one millimeter.

  17. X-ray focal spot reconstruction by circular penumbra analysis—Application to digital radiography systems

    Energy Technology Data Exchange (ETDEWEB)

    Di Domenico, Giovanni, E-mail: didomenico@fe.infn.it; Cardarelli, Paolo; Taibi, Angelo; Gambaccini, Mauro [Dipartimento di Fisica e Scienze della Terra, Università degli Studi di Ferrara, via Saragat 1, FE I-44122, Italy and INFN - sezione di Ferrara, via Saragat 1, FE I-44122 (Italy); Contillo, Adriano [Dipartimento di Fisica e Scienze della Terra, Università degli Studi di Ferrara, via Saragat 1, FE I-44122 (Italy)

    2016-01-15

    Purpose: The quality of a radiography system is affected by several factors, a major one being the focal spot size of the x-ray tube. In fact, the measurement of such size is recognized to be of primary importance during acceptance tests and image quality evaluations of clinical radiography systems. The most common device providing an image of the focal spot emission distribution is a pin-hole camera, which requires a high tube loading in order to produce a measurable signal. This work introduces an alternative technique to obtain an image of the focal spot, through the processing of a single radiograph of a simple test object, acquired with a suitable magnification. Methods: The radiograph of a magnified sharp edge is a well-established method to evaluate the extension of the focal spot profile along the direction perpendicular to the edge. From a single radiograph of a circular x-ray absorber, it is possible to extract simultaneously the radial profiles of several sharp edges with different orientations. The authors propose a technique that allows to obtain an image of the focal spot through the processing of these radial profiles by means of a pseudo-CT reconstruction technique. In order to validate this technique, the reconstruction has been applied to the simulated radiographs of an ideal disk-shaped absorber, generated by various simulated focal spot distributions. Furthermore, the method has been applied to the focal spot of a commercially available mammography unit. Results: In the case of simulated radiographs, the results of the reconstructions have been compared to the original distributions, showing an excellent agreement for what regards both the overall distribution and the full width at half maximum measurements. In the case of the experimental test, the method allowed to obtain images of the focal spot that have been compared with the results obtained through standard techniques, namely, pin-hole camera and slit camera. Conclusions: The method was

  18. Genetics Home Reference: familial focal epilepsy with variable foci

    Science.gov (United States)

    ... epilepsy with variable foci Familial focal epilepsy with variable foci Printable PDF Open All Close All Enable ... expand/collapse boxes. Description Familial focal epilepsy with variable foci (FFEVF) is an uncommon form of recurrent ...

  19. Telomere length analysis.

    Science.gov (United States)

    Canela, Andrés; Klatt, Peter; Blasco, María A

    2007-01-01

    Most somatic cells of long-lived species undergo telomere shortening throughout life. Critically short telomeres trigger loss of cell viability in tissues, which has been related to alteration of tissue function and loss of regenerative capabilities in aging and aging-related diseases. Hence, telomere length is an important biomarker for aging and can be used in the prognosis of aging diseases. These facts highlight the importance of developing methods for telomere length determination that can be employed to evaluate telomere length during the human aging process. Telomere length quantification methods have improved greatly in accuracy and sensitivity since the development of the conventional telomeric Southern blot. Here, we describe the different methodologies recently developed for telomere length quantification, as well as their potential applications for human aging studies.

  20. Focal tracer uptake in the jaw.

    Science.gov (United States)

    El-Zahry, Mai R; Sinzinger, Helmut

    2014-01-01

    Focal tracer uptake in the jaw during conventional bone scintigraphy is a quite frequent finding usually due to dental disease and seldom to other diseases including malignant disease. Methylene diphosphonate-technetium-99m ((99m)Tc-MDP) 3-phase bone scan is considered the most sensitive imaging method for the detection of jaw osteonecrosis at an early stage. This finding can also but seldom be seen in patients undergoing palliative radionuclide treatment for bone metastases. In conclusion, focal jaw lesions are usually benign and of dental origin. In a small percentage of cancer patients of about 4.3%, jaw lesions as diagnosed among 347 cases of various carcinomas may be due to malignancy. Unfortunately, the number of studies is small, most of them are retrospective and few show biopsy results.

  1. Membership Functions for Fuzzy Focal Elements

    Directory of Open Access Journals (Sweden)

    Porębski Sebastian

    2016-09-01

    Full Text Available The paper presents a study on data-driven diagnostic rules, which are easy to interpret by human experts. To this end, the Dempster-Shafer theory extended for fuzzy focal elements is used. Premises of the rules (fuzzy focal elements are provided by membership functions which shapes are changing according to input symptoms. The main aim of the present study is to evaluate common membership function shapes and to introduce a rule elimination algorithm. Proposed methods are first illustrated with the popular Iris data set. Next experiments with five medical benchmark databases are performed. Results of the experiments show that various membership function shapes provide different inference efficiency but the extracted rule sets are close to each other. Thus indications for determining rules with possible heuristic interpretation can be formulated.

  2. Chest pain in focal musculoskeletal disorders

    DEFF Research Database (Denmark)

    Stochkendahl, Mette Jensen; Christensen, Henrik Wulff

    2010-01-01

    The musculoskeletal system is a recognized source of chest pain. However, despite the apparently benign origin, patients with musculoskeletal chest pain remain under-diagnosed, untreated, and potentially continuously disabled in terms of anxiety, depression, and activities of daily living. Several...... overlapping conditions and syndromes of focal disorders, including Tietze syndrome, costochondritis, chest wall syndrome, muscle tenderness, slipping rib, cervical angina, and segmental dysfunction of the cervical and thoracic spine, have been reported to cause pain. For most of these syndromes, evidence...... arises mainly from case stories and empiric knowledge. For segmental dysfunction, clinical features of musculoskeletal chest pain have been characterized in a few clinical trials. This article summarizes the most commonly encountered syndromes of focal musculoskeletal disorders in clinical practice....

  3. Focal plane AIT sequence: evolution from HRG-Spot 5 to Pleiades HR

    Science.gov (United States)

    Le Goff, Roland; Pranyies, Pascal; Toubhans, Isabelle

    2017-11-01

    Optical and geometrical image qualities of Focal Planes, for "push-broom" high resolution remote sensing satellites, require the implementation of specific means and methods for the AIT sequence. Indeed the geometric performances of the focal plane mainly axial focusing and transverse registration, are duly obtained on the basis of adjustment, setting and measurement of optical and CCD components with an accuracy of a few microns. Since the end of the 1970s, EADS-SODERN has developed a series of detection units for earth observation instruments like SPOT and Helios. And EADS-SODERN is now responsible for the development of the Pleiades High Resolution Focal Plane assembly. This paper presents the AIT sequences. We introduce all the efforts, innovative solutions and improvements made on the assembly facilities to match the technical evolutions and breakthrough of the Pleiades HR FP concept in comparison with the previous High Resolution Geometric SPOT 5 Focal Plane. The main evolution drivers are the implementation of strip filters and the realization of 400 mm continuous retinas. For Pleiades HR AIT sequence, three specific integration and measuring benches, corresponding with the different assembly stages, are used: a 3-D non-contact measurement machine for the assembly of detection module, a 3-D measurement machine for mirror integration on the main Focal Plane SiC structure, and a 3-D geometric coordinates control bench to focus detection module lines and to ensure they are well registered together.

  4. Multispecies, Integrative GWAS for Focal Segmental Glomerulosclerosis

    Science.gov (United States)

    2017-09-01

    Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person ...project are to identify genetic determinants of focal segmental glomerulosclerosis (FSGS) using genomewide association studies in mouse strains. We have...OF PAGES  17 19a. NAME OF RESPONSIBLE PERSON USAMRMC a. REPORT u  b. ABSTRACT u  c. THIS PAGE u  19b. TELEPHONE NUMBER (Include area

  5. Proximal focal femoral deficiency: A case report

    Directory of Open Access Journals (Sweden)

    Shashank Sharma

    2015-01-01

    Full Text Available Proximal focal femoral deficiency (PFFD is a rare congenital anomaly resulting in limb shortening and disability in young. The exact cause of the disease is not known and it may present as varying grades of affection involving the proximal femur and the acetabulum. Recognition of this rare abnormality on radiographs can help manage these cases better since early institution of therapy may help in achieving adequate growth of the femur.

  6. Focal epileptic seizures mimicking sleep paralysis.

    Science.gov (United States)

    Galimberti, Carlo Andrea; Ossola, Maria; Colnaghi, Silvia; Arbasino, Carla

    2009-03-01

    Sleep paralysis (SP) is a common parasomnia. The diagnostic criteria for SP, as reported in the International Classification of Sleep Disorders, are essentially clinical, as electroencephalography (EEG)-polysomnography (PSG) is not mandatory. We describe a subject whose sleep-related events fulfilled the diagnostic criteria for SP, even though her visual hallucinations were elementary, repetitive and stereotyped, thus differing from those usually reported by patients with SP. Video/EEG-PSG documented the focal epileptic nature of the SP-like episodes.

  7. Focal Scalp Hair Heterochromia in an Infant.

    Science.gov (United States)

    Kumar, Pramod

    2017-02-01

    Hair heterochromia involves the presence of two different non-artificially induced colours of hair in the same individual which can be due to either iron deficiency anaemia, genetic mutations or mosaicism. We report a six-month old male infant who presented to the Department of Dermatology, Saham Hospital, Saham, Oman, in 2013 with focal scalp hair heterochromia without any detectable underlying abnormalities. The area of heterochromia was still noticeable at a one-year follow-up.

  8. Focal Scalp Hair Heterochromia in an Infant

    OpenAIRE

    Kumar, Pramod

    2017-01-01

    Hair heterochromia involves the presence of two different non-artificially induced colours of hair in the same individual which can be due to either iron deficiency anaemia, genetic mutations or mosaicism. We report a six-month old male infant who presented to the Department of Dermatology, Saham Hospital, Saham, Oman, in 2013 with focal scalp hair heterochromia without any detectable underlying abnormalities. The area of heterochromia was still noticeable at a one-year follow-up.

  9. Focal Scalp Hair Heterochromia in an Infant

    Directory of Open Access Journals (Sweden)

    Pramod Kumar

    2017-03-01

    Full Text Available Hair heterochromia involves the presence of two different non-artificially induced colours of hair in the same individual which can be due to either iron deficiency anaemia, genetic mutations or mosaicism. We report a six-month old male infant who presented to the Department of Dermatology, Saham Hospital, Saham, Oman, in 2013 with focal scalp hair heterochromia without any detectable underlying abnormalities. The area of heterochromia was still noticeable at a one-year follow-up.

  10. Focal plane scanner with reciprocating spatial window

    Science.gov (United States)

    Mao, Chengye (Inventor)

    2000-01-01

    A focal plane scanner having a front objective lens, a spatial window for selectively passing a portion of the image therethrough, and a CCD array for receiving the passed portion of the image. All embodiments have a common feature whereby the spatial window and CCD array are mounted for simultaneous relative reciprocating movement with respect to the front objective lens, and the spatial window is mounted within the focal plane of the front objective. In a first embodiment, the spatial window is a slit and the CCD array is one-dimensional, and successive rows of the image in the focal plane of the front objective lens are passed to the CCD array by an image relay lens interposed between the slit and the CCD array. In a second embodiment, the spatial window is a slit, the CCD array is two-dimensional, and a prism-grating-prism optical spectrometer is interposed between the slit and the CCD array so as to cause the scanned row to be split into a plurality of spectral separations onto the CCD array. In a third embodiment, the CCD array is two-dimensional and the spatial window is a rectangular linear variable filter (LVF) window, so as to cause the scanned rows impinging on the LVF to be bandpass filtered into spectral components onto the CCD array through an image relay lens interposed between the LVF and the CCD array.

  11. Focal Conic Flower Textures at Curved Interfaces

    Directory of Open Access Journals (Sweden)

    Daniel A. Beller

    2013-12-01

    Full Text Available Focal conic domains (FCDs in smectic-A liquid crystals have drawn much attention, both for their exquisitely structured internal form and for their ability to direct the assembly of micromaterials and nanomaterials in a variety of patterns. A key to directing FCD assembly is control over the eccentricity of the domain. Here, we demonstrate a new paradigm for creating spatially varying FCD eccentricity by confining a hybrid-aligned smectic with curved interfaces. In particular, we manipulate interface behavior with colloidal particles in order to experimentally produce two examples of what has recently been dubbed the flower texture [C. Meyer et al., Focal Conic Stacking in Smectic A Liquid Crystals: Smectic Flower and Apollonius Tiling, Materials 2, 499, 2009MATEG91996-194410.3390/ma2020499], where the focal hyperbolæ diverge radially outward from the center of the texture, rather than inward as in the canonical éventail or fan texture. We explain how this unconventional assembly can arise from appropriately curved interfaces. Finally, we present a model for this system that applies the law of corresponding cones, showing how FCDs may be embedded smoothly within a “background texture” of large FCDs and concentric spherical layers, in a manner consistent with the qualitative features of the smectic flower. Such understanding could potentially lead to disruptive liquid-crystal technologies beyond displays, including patterning, smart surfaces, microlens arrays, sensors, and nanomanufacturing.

  12. Validity of hamstring muscle length assessment during the sit-and-reach test using an inclinometer to measure hip joint angle.

    Science.gov (United States)

    Youdas, James W; Krause, David A; Hollman, John H

    2008-01-01

    The aim of this study was twofold: (i) to describe the criterion-related validity of the sit-and-reach test (SRT) using a hand-held inclinometer when assessing hamstring muscle length (HML) when HML is recorded in degrees of hip joint angle (HJA); and (ii) to describe the effect of gender and age on HML in healthy adults during the performance of a SRT. We examined 212 healthy subjects (106 men and 106 women) whose ages ranged from 20 to 79 years. The Pearson-product moment correlation coefficient (r) described the relationship between HJA at the end-point of the SRT and the criterion, supine passive straight-leg raise (PSLR). We conducted a 6 x 2 analysis of variance, where age was stratified on 6 levels of 10-year increments (20-29, 30-39, 40-49, 50-59, 60-69, and 70-79 years of age) and gender was stratified on 2 levels (men and women). There was a statistically significant correlation (r = 0.59, P sitting position on a hard surface. Clinicians should recognize there are differences in HML between men and women, and that men and women between 20 to 49 years of age have more HML than their counterparts between ages 60 to 79 years.

  13. Multispectral linear array (MLA) focal plane mechanical and thermal design

    Science.gov (United States)

    Mitchell, A. S.; Kaminski, E. F.

    1982-01-01

    The mechanical and thermal design of an integrated focal plane subsystem of a Multispectral Linear Array (MLA) instrument is discussed in terms of focal-plane alignment, thermoelastic performance, and thermal requirements. The modular construction and thermal control of the focal plane array are discussed.

  14. Substrate, focal adhesions, and actin filaments: a mechanical unit with a weak spot for mechanosensitive proteins

    International Nuclear Information System (INIS)

    Kirchenbuechler, David; Born, Simone; Kirchgessner, Norbert; Houben, Sebastian; Hoffmann, Bernd; Merkel, Rudolf

    2010-01-01

    Mechanosensing is a vital prerequisite for dynamic remodeling of focal adhesions and cytoskeletal structures upon substrate deformation. For example, tissue formation, directed cell orientation or cell differentiation are regulated by such mechanosensing processes. Focal adhesions and the actin cytoskeleton are believed to be involved in these processes, but where mechanosensing molecules are located and how elastic substrate, focal adhesions and the cytoskeleton couple with each other upon substrate deformation still remains obscure. To approach these questions we have developed a sensitive method to apply defined spatially decaying deformation fields to cells cultivated on ultrasoft elastic substrates and to accurately quantify the resulting displacements of the actin cytoskeleton, focal adhesions, as well as the substrate. Displacement fields were recorded in live cell microscopy by tracking either signals from fluorescent proteins or marker particles in the substrate. As model cell type we used myofibroblasts. These cells are characterized by highly stable adhesion and force generating structures but are still able to detect mechanical signals with high sensitivity. We found a rigid connection between substrate and focal adhesions. Furthermore, stress fibers were found to be barely extendable almost over their whole lengths. Plastic deformation took place only at the very ends of actin filaments close to focal adhesions. As a result, this area became elongated without extension of existing actin filaments by polymerization. Both ends of the stress fibers were mechanically coupled with detectable plastic deformations on either site. Interestingly, traction force dependent substrate deformation fields remained mostly unaffected even when stress fiber elongations were released. These data argue for a location of mechanosensing proteins at the ends of actin stress fibers and describe, except for these domains, the whole system to be relatively rigid for tensile

  15. Kalman Filter for Calibrating a Telescope Focal Plane

    Science.gov (United States)

    Kang, Bryan; Bayard, David

    2006-01-01

    The instrument-pointing frame (IPF) Kalman filter, and an algorithm that implements this filter, have been devised for calibrating the focal plane of a telescope. As used here, calibration signifies, more specifically, a combination of measurements and calculations directed toward ensuring accuracy in aiming the telescope and determining the locations of objects imaged in various arrays of photodetectors in instruments located on the focal plane. The IPF Kalman filter was originally intended for application to a spaceborne infrared astronomical telescope, but can also be applied to other spaceborne and ground-based telescopes. In the traditional approach to calibration of a telescope, (1) one team of experts concentrates on estimating parameters (e.g., pointing alignments and gyroscope drifts) that are classified as being of primarily an engineering nature, (2) another team of experts concentrates on estimating calibration parameters (e.g., plate scales and optical distortions) that are classified as being primarily of a scientific nature, and (3) the two teams repeatedly exchange data in an iterative process in which each team refines its estimates with the help of the data provided by the other team. This iterative process is inefficient and uneconomical because it is time-consuming and entails the maintenance of two survey teams and the development of computer programs specific to the requirements of each team. Moreover, theoretical analysis reveals that the engineering/ science iterative approach is not optimal in that it does not yield the best estimates of focal-plane parameters and, depending on the application, may not even enable convergence toward a set of estimates.

  16. Fractional baud-length coding

    Directory of Open Access Journals (Sweden)

    J. Vierinen

    2011-06-01

    Full Text Available We present a novel approach for modulating radar transmissions in order to improve target range and Doppler estimation accuracy. This is achieved by using non-uniform baud lengths. With this method it is possible to increase sub-baud range-resolution of phase coded radar measurements while maintaining a narrow transmission bandwidth. We first derive target backscatter amplitude estimation error covariance matrix for arbitrary targets when estimating backscatter in amplitude domain. We define target optimality and discuss different search strategies that can be used to find well performing transmission envelopes. We give several simulated examples of the method showing that fractional baud-length coding results in smaller estimation errors than conventional uniform baud length transmission codes when estimating the target backscatter amplitude at sub-baud range resolution. We also demonstrate the method in practice by analyzing the range resolved power of a low-altitude meteor trail echo that was measured using a fractional baud-length experiment with the EISCAT UHF system.

  17. Myofilament length dependent activation

    Energy Technology Data Exchange (ETDEWEB)

    de Tombe, Pieter P.; Mateja, Ryan D.; Tachampa, Kittipong; Mou, Younss Ait; Farman, Gerrie P.; Irving, Thomas C. (IIT); (Loyola)

    2010-05-25

    The Frank-Starling law of the heart describes the interrelationship between end-diastolic volume and cardiac ejection volume, a regulatory system that operates on a beat-to-beat basis. The main cellular mechanism that underlies this phenomenon is an increase in the responsiveness of cardiac myofilaments to activating Ca{sup 2+} ions at a longer sarcomere length, commonly referred to as myofilament length-dependent activation. This review focuses on what molecular mechanisms may underlie myofilament length dependency. Specifically, the roles of inter-filament spacing, thick and thin filament based regulation, as well as sarcomeric regulatory proteins are discussed. Although the 'Frank-Starling law of the heart' constitutes a fundamental cardiac property that has been appreciated for well over a century, it is still not known in muscle how the contractile apparatus transduces the information concerning sarcomere length to modulate ventricular pressure development.

  18. Spatial noise in staring IR focal plane arrays

    International Nuclear Information System (INIS)

    Scribner, D.A.; Kruer, M.R.; Sarkady, K.; Gridley, J.C.

    1988-01-01

    Problems with nonuniformity correction algorithms due to nonlinear pixel response and 1/f noise have been shown previously to cause spatial noise which can be significantly greater than temporal noise. The residual spatial noise after correction cannot be reduced with time averaging. Because of spatial noise the sensitivity of staring FPA sensors is often less than predicted on the basis of the temporal noise of the individual elements. A review is given of methods for measuring and analyzing spatial noise (after nonuniformity correction) in staring infrared focal plane arrays. Automated measurement techniques are described briefly, including necessary equipment and data reduction procedures. An example of spatial noise measurements is given using a staring InSb Charge Injection Device (CID) array

  19. The role of executive functioning in memory performance in pediatric focal epilepsy

    Science.gov (United States)

    Sepeta, Leigh N.; Casaletto, Kaitlin Blackstone; Terwilliger, Virginia; Facella-Ervolini, Joy; Sady, Maegan; Mayo, Jessica; Gaillard, William D.; Berl, Madison M.

    2016-01-01

    Objective Learning and memory are essential for academic success and everyday functioning, but the pattern of memory skills and its relationship to executive functioning in children with focal epilepsy is not fully delineated. We address a gap in the literature by examining the relationship between memory and executive functioning in a pediatric focal epilepsy population. Methods Seventy children with focal epilepsy and 70 typically developing children matched on age, intellectual functioning, and gender underwent neuropsychological assessment, including measures of intelligence (WASI/DAS), as well as visual (CMS Dot Locations) and verbal episodic memory (WRAML Story Memory and CVLT-C). Executive functioning was measured directly (WISC-IV Digit Span Backward; CELF-IV Recalling Sentences) and by parent report (Behavior Rating Inventory of Executive Function (BRIEF)). Results Children with focal epilepsy had lower delayed free recall scores than controls across visual and verbal memory tasks (p = 0.02; partial η2 = .12). In contrast, recognition memory performance was similar for patients and controls (p = 0.36; partial η2 = .03). Children with focal epilepsy demonstrated difficulties in working memory (p = 0.02; partial η2 = .08) and planning/organization (p = 0.02) compared to controls. Working memory predicted 9–19% of the variance in delayed free recall for verbal and visual memory; organization predicted 9–10% of the variance in verbal memory. Patients with both left and right focal epilepsy demonstrated more difficulty on verbal versus visual tasks (p = 0.002). Memory performance did not differ by location of seizure foci (temporal vs. extra-temporal, frontal vs. extra-frontal). Significance Children with focal epilepsy demonstrated memory ability within age-level expectations, but delayed free recall was inefficient compared to typically developing controls. Memory difficulties were not related to general cognitive impairment or seizure localization

  20. Upper Extremity Length Equalization

    OpenAIRE

    DeCoster, Thomas A.; Ritterbusch, John; Crawford, Mark

    1992-01-01

    Significant upper extremity length inequality is uncommon but can cause major functional problems. The ability to position and use the hand may be impaired by shortness of any of the long bones of the upper extremity. In many respects upper and lower extremity length problems are similar. They most commonly occur after injury to a growing bone and the treatment modalities utilized in the lower extremity may be applied to the upper extremity. These treatment options include epiphysiodesis, sho...

  1. Focal increase of cerebral blood flow during stereognostic testing in man

    DEFF Research Database (Denmark)

    Roland, E; Larsen, B

    1976-01-01

    An attempt was made to study the regional cerebral blood flow (rCBF) pattern during stereognostic discrimination in man. The rCBF was measured in 18 subjects who had no major neurological defects. The clearance from the hemisphere of xenon 133 injected (133Xe) into the carotid artery was measured...... with a 254-channel dynamic gamma camera. During stereognostic discrimination with hand, mouth, or foot, the rCBF increased focally in the corresponding contralateral sensory-motor region and increased focally in the premotor part of the frontal lobe. The increase in the sensory region was attributed...

  2. Analysis of ureteral length in adult cadavers

    Directory of Open Access Journals (Sweden)

    Hugo F. F. Novaes

    2013-04-01

    Full Text Available Introduction In some occasions, correlations between human structures can help planning surgical intra-abdominal interventions. The previous determination of ureteral length helps pre-operatory planning of surgeries, reduces costs of auxiliary exams, the correct choice of double-J catheter with low morbidity and fewer symptoms, and an adequate adhesion to treatment. Objective To evaluate ureteral length in adult cadavers and to analyze its correlation with anthropometric measures. Materials and Methods: From April 2009 to January 2012 we determined ureteral length of adult cadavers submitted to necropsy and obtained the following measures: height, distance from shoulder to wrist, elbow-wrist, xiphoid appendix-umbilicus, umbilicus-pubis, xiphoid appendix-pubis and between iliac spines. We analyzed the correlations between ureteral length and those anthropometric measures. Results We dissected 115 ureters from 115 adult corpses from April 2009 to January 2012. Median ureteral length didn't vary between sexes or according to height. It was observed no correlation among ureteral length and all considered anthropometric measures in all analyzed subgroups and in general population. There were no significant differences between right and left ureteral measures. Conclusions There is no difference of ureteral length in relation to height or gender (male or female. There is no significant correlation among ureteral length and the considered anthropometric measures.

  3. Focal Anterior Displacement of the Thoracic Spinal Cord without Evidence of Spinal Cord Herniation or an Intradural Mass

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Yoon; Lee, Joon Woo; Lee, Guen Young; Kang, Heung Sik [Department of Radiology, Seoul National University Bundang Hospital, Seongnam 463-707 (Korea, Republic of)

    2014-07-01

    We report magnetic resonance imaging (MRI) findings on focal anterior displacement of the thoracic spinal cord in asymptomatic patients without a spinal cord herniation or intradural mass. We identified 12 patients (male:female = 6:6; mean age, 51.7; range, 15-83 years) between 2007 and 2011, with focal anterior displacement of the spinal cord and without evidence of an intradural mass or spinal cord herniation. Two radiologists retrospectively reviewed the MRI findings in consensus. An asymmetric spinal cord deformity with a focal dented appearance was seen on the posterior surface of the spinal cord in all patients, and it involved a length of 1 or 2 vertebral segments in the upper thoracic spine (thoracic vertebrae 1-6). Moreover, a focal widening of the posterior subarachnoid space was also observed in all cases. None of the patients had myelopathy symptoms, and they showed no focal T2-hyperintensity in the spinal cord with the exception of one patient. In addition, cerebrospinal fluid (CSF) flow artifacts were seen in the posterior subarachnoid space of the affected spinal cord level. Computed tomography myelography revealed preserved CSF flow in the two available patients. Focal anterior spinal cord indentation can be found in the upper thoracic level of asymptomatic patients without a spinal cord herniation or intradural mass.

  4. Focal Anterior Displacement of the Thoracic Spinal Cord without Evidence of Spinal Cord Herniation or an Intradural Mass

    International Nuclear Information System (INIS)

    Lee, Jong Yoon; Lee, Joon Woo; Lee, Guen Young; Kang, Heung Sik

    2014-01-01

    We report magnetic resonance imaging (MRI) findings on focal anterior displacement of the thoracic spinal cord in asymptomatic patients without a spinal cord herniation or intradural mass. We identified 12 patients (male:female = 6:6; mean age, 51.7; range, 15-83 years) between 2007 and 2011, with focal anterior displacement of the spinal cord and without evidence of an intradural mass or spinal cord herniation. Two radiologists retrospectively reviewed the MRI findings in consensus. An asymmetric spinal cord deformity with a focal dented appearance was seen on the posterior surface of the spinal cord in all patients, and it involved a length of 1 or 2 vertebral segments in the upper thoracic spine (thoracic vertebrae 1-6). Moreover, a focal widening of the posterior subarachnoid space was also observed in all cases. None of the patients had myelopathy symptoms, and they showed no focal T2-hyperintensity in the spinal cord with the exception of one patient. In addition, cerebrospinal fluid (CSF) flow artifacts were seen in the posterior subarachnoid space of the affected spinal cord level. Computed tomography myelography revealed preserved CSF flow in the two available patients. Focal anterior spinal cord indentation can be found in the upper thoracic level of asymptomatic patients without a spinal cord herniation or intradural mass

  5. Does sleep deprivation alter functional EEG networks in children with focal epilepsy?

    Directory of Open Access Journals (Sweden)

    Eric evan Diessen

    2014-04-01

    Full Text Available Electroencephalography (EEG recordings after sleep deprivation increase the diagnostic yield in patients suspected of epilepsy if the routine EEG remains inconclusive. Sleep deprivation is associated with increased interictal EEG abnormalities in patients with epilepsy, but the exact mechanism is unknown. In this feasibility study, we used a network analytical approach to provide novel insights into this clinical observation. The aim was to characterize the effect of sleep deprivation on interictal functional network organization using a unique dataset of paired routine and sleep deprivation recordings in patients and controls. We included twenty-one children referred to the first seizure clinic of our center with suspected new onset focal epilepsy in whom a routine interictal and a sleep deprivation EEG (SD-EEG were performed. Seventeen children, in whom the diagnosis of epilepsy was excluded, served as controls. For both time points weighted functional networks were constructed based on interictal artifact free time-series. Routine and sleep deprivation networks were characterized at different frequency bands using minimum spanning tree (MST measures (leaf number and diameter and classical measures of integration (path length and segregation (clustering coefficient. A significant interaction was found for leaf number and diameter between patients and controls after sleep deprivation: patients showed a shift towards a more path-like MST network whereas controls showed a shift towards a more star-like MST network. This shift in network organization after sleep deprivation in patients is in accordance with previous studies showing a more regular network organization in the ictal state and might relate to the increased epileptiform abnormalities found in patients after sleep deprivation. Larger studies are needed to verify these results. Finally, MST measures were more sensitive in detecting network changes as compared to the classical measures of

  6. Focal Molography: Coherent Microscopic Detection of Biomolecular Interaction

    Directory of Open Access Journals (Sweden)

    Christof Fattinger

    2014-08-01

    Full Text Available We introduce and theoretically investigate here a novel analytical method that we have called focal molography, in which molecular interactions are made visible through scattering of coherent light by a coherent pattern of molecules. The scattered light quantifies the presence of molecules at molecular interaction sites. It is separated from noncoherent background scatter by a combination of local dark-field illumination, interference enhancement, and spatial filtering. The latter is achieved by holographic focusing of the wave field generated by the coherently assembled molecules onto an Airy disk and by subtraction of the noncoherent irradiance in the focal plane outside the disk from the irradiance in the disk. This new microscopic method allows distinct detection of low-refractive-index contrast in the nanoenvironment of biomolecules from which information on the interaction of the coherently assembled molecules with molecules in a liquid or gaseous sample may be deduced. The noncoherent surroundings of the coherently assembled molecules consist of freely diffusing solvent and solute molecules. The surroundings, as well as changes in temperature, do not contribute to the coherent signal in the diffraction focus. Interference lithography or high-resolution-imaging lithography can be used to synthesize the coherent pattern of molecules on a monolithic substrate. The coherent pattern of molecules constitutes a synthetic phase hologram that creates a diffraction-limited light wave. We suggest the term “mologram” for the coherent assembly of functional nanostructures and the term “focal molography” for label-free or labeled analysis of molecular interactions through the measurement of the properties of light in the focus of the mologram. We derive analytical formulas that express the detection signal and the sensitivity of focal molography on the surface of a high-refractive-index thin-film optical waveguide in terms of known parameters

  7. Innovative compact focal plane array for wide field vis and ir orbiting telescopes

    Science.gov (United States)

    Hugot, Emmanuel; Vives, Sébastien; Ferrari, Marc; Gaeremynck, Yann; Jahn, Wilfried

    2017-11-01

    The future generation of high angular resolution space telescopes will require breakthrough technologies to combine large diameters and large focal plane arrays with compactness and lightweight mirrors and structures. Considering the allocated volume medium-size launchers, short focal lengths are mandatory, implying complex optical relays to obtain diffraction limited images on large focal planes. In this paper we present preliminary studies to obtain compact focal plane arrays (FPA) for earth observations on low earth orbits at high angular resolution. Based on the principle of image slicers, we present an optical concept to arrange a 1D FPA into a 2D FPA, allowing the use of 2D detector matrices. This solution is particularly attractive for IR imaging requiring a cryostat, which volume could be considerably reduced as well as the relay optics complexity. Enabling the use of 2D matrices for such an application offers new possibilities. Recent developments on curved FPA allows optimization without concerns on the field curvature. This innovative approach also reduces the complexity of the telescope optical combination, specifically for fast telescopes. This paper will describe the concept and optical design of an F/5 - 1.5m telescope equipped with such a FPA, the performances and the impact on the system with a comparison with an equivalent 1.5m wide field Korsch telescope.

  8. Focal inflammatory diseases of the liver

    International Nuclear Information System (INIS)

    Oto, Aytekin; Akhan, Okan; Oezmen, Mustafa

    1999-01-01

    Inflammatory lesions constitute an important subgroup of focal liver lesions. They may mimic primary or metastatic neoplastic lesions and their differentiation from neoplasia is clinically very important since management of the patient significantly changes. Radiologists should have an important role in both the diagnosis and therapy of these lesions by performing percutaneous aspirations and drainages. In this review we discussed the radiological findings of pyogenic abscesses, amebic abscesses, candidiasis, tuberculosis, hydatic cysts, fascioliasis, ascariasis, schistosomiasis, and sarcoidosis with a special emphasis on US, CT and MR characteristics

  9. Focal inflammatory diseases of the liver

    Energy Technology Data Exchange (ETDEWEB)

    Oto, Aytekin; Akhan, Okan; Oezmen, Mustafa

    1999-10-01

    Inflammatory lesions constitute an important subgroup of focal liver lesions. They may mimic primary or metastatic neoplastic lesions and their differentiation from neoplasia is clinically very important since management of the patient significantly changes. Radiologists should have an important role in both the diagnosis and therapy of these lesions by performing percutaneous aspirations and drainages. In this review we discussed the radiological findings of pyogenic abscesses, amebic abscesses, candidiasis, tuberculosis, hydatic cysts, fascioliasis, ascariasis, schistosomiasis, and sarcoidosis with a special emphasis on US, CT and MR characteristics.

  10. Focal Myasthenia Gravis in Two Dogs

    Directory of Open Access Journals (Sweden)

    Ayman Atiba

    2014-07-01

    Full Text Available Two dogs were presented with history of regurgitation. Both dogs were diagnosed with focal myasthenia gravis (FMG. Thoracic radiography was consisted with megaesophagus. Acetylcholine receptors (AChRs antibody titer was positive. Both dogs were treated with pyridostigmine bromide as sole treatment. One case rapidly resolved with the recovery of the esophagus, while the other case even the AChRs antibody titer was normalized after 60 days but the clinical remission was occurred after long time. This report suggested that clinical signs of FMG were resolved, but we can’t predict the time required, additionally, pyridostigmine bromide might be effective for palliation of symptoms.

  11. Characterization of DECam focal plane detectors

    Energy Technology Data Exchange (ETDEWEB)

    Diehl, H.Thomas; Angstadt, Robert; Campa, Julia; Cease, Herman; Derylo, Greg; Emes, John H.; Estrada, Juan; Kibik, Donna; Flaugher, Brenna L.; Holland, Steve E.; Jonas, Michelle; /Fermilab /Madrid, CIEMAT /LBL, Berkeley /Argonne /Pennsylvania U.

    2008-06-01

    DECam is a 520 Mpix, 3 square-deg FOV imager being built for the Blanco 4m Telescope at CTIO. This facility instrument will be used for the 'Dark Energy Survey' of the southern galactic cap. DECam has chosen 250 ?m thick CCDs, developed at LBNL, with good QE in the near IR for the focal plane. In this work we present the characterization of these detectors done by the DES team, and compare it to the DECam technical requirements. The results demonstrate that the detectors satisfy the needs for instrument.

  12. Precision Laser Annealing of Focal Plane Arrays

    Energy Technology Data Exchange (ETDEWEB)

    Bender, Daniel A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); DeRose, Christopher [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Starbuck, Andrew Lea [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Verley, Jason C. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jenkins, Mark W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-09-01

    We present results from laser annealing experiments in Si using a passively Q-switched Nd:YAG microlaser. Exposure with laser at fluence values above the damage threshold of commercially available photodiodes results in electrical damage (as measured by an increase in photodiode dark current). We show that increasing the laser fluence to values in excess of the damage threshold can result in annealing of a damage site and a reduction in detector dark current by as much as 100x in some cases. A still further increase in fluence results in irreparable damage. Thus we demonstrate the presence of a laser annealing window over which performance of damaged detectors can be at least partially reconstituted. Moreover dark current reduction is observed over the entire operating range of the diode indicating that device performance has been improved for all values of reverse bias voltage. Additionally, we will present results of laser annealing in Si waveguides. By exposing a small (<10 um) length of a Si waveguide to an annealing laser pulse, the longitudinal phase of light acquired in propagating through the waveguide can be modified with high precision, <15 milliradian per laser pulse. Phase tuning by 180 degrees is exhibited with multiple exposures to one arm of a Mach-Zehnder interferometer at fluence values below the morphological damage threshold of an etched Si waveguide. No reduction in optical transmission at 1550 nm was found after 220 annealing laser shots. Modeling results for laser annealing in Si are also presented.

  13. Using the focal phase to control attosecond processes

    Science.gov (United States)

    Hoff, Dominik; Krüger, Michael; Maisenbacher, Lothar; Paulus, Gerhard G.; Hommelhoff, Peter; Sayler, A. M.

    2017-12-01

    The spatial evolution of the electric field of focused broadband light is crucial for many emerging attosecond technologies. Here the effects of the input beam parameters on the evolution of few-cycle laser pulses in the focus are discussed. Specifically, we detail how the frequency-dependent input beam geometry, chirp and chromatic aberration can affect the spatial dependence of the carrier-envelope phase (CEP), central frequency and pulse duration in the focus. These effects are confirmed by a direct, three-dimensional measurement of the CEP-evolution in the focus of a typical few-cycle pulse laser using electron rescattering at metal nanotips in combination with a CEP-metre. Moreover, we demonstrate a simple measurement technique to estimate the focal CEP evolution by input-beam parameters. These parameters can be used in novel ways in order to control attosecond dynamics and tailor highly nonlinear light–matter interactions.

  14. Relativistic Length Agony Continued

    Science.gov (United States)

    Redzic, D. V.

    2014-06-01

    We made an attempt to remedy recent confusing treatments of some basic relativistic concepts and results. Following the argument presented in an earlier paper (Redzic 2008b), we discussed the misconceptions that are recurrent points in the literature devoted to teaching relativity such as: there is no change in the object in Special Relativity, illusory character of relativistic length contraction, stresses and strains induced by Lorentz contraction, and related issues. We gave several examples of the traps of everyday language that lurk in Special Relativity. To remove a possible conceptual and terminological muddle, we made a distinction between the relativistic length reduction and relativistic FitzGerald-Lorentz contraction, corresponding to a passive and an active aspect of length contraction, respectively; we pointed out that both aspects have fundamental dynamical contents. As an illustration of our considerations, we discussed briefly the Dewan-Beran-Bell spaceship paradox and the 'pole in a barn' paradox.

  15. Telomere Length and Mortality

    DEFF Research Database (Denmark)

    Kimura, Masayuki; Hjelmborg, Jacob V B; Gardner, Jeffrey P

    2008-01-01

    Leukocyte telomere length, representing the mean length of all telomeres in leukocytes, is ostensibly a bioindicator of human aging. The authors hypothesized that shorter telomeres might forecast imminent mortality in elderly people better than leukocyte telomere length. They performed mortality...... telomeres predicted the death of the first co-twin better than the mTRFL did (mTRFL: 0.56, 95% confidence interval (CI): 0.49, 0.63; mTRFL(50): 0.59, 95% CI: 0.52, 0.66; mTRFL(25): 0.59, 95% CI: 0.52, 0.66; MTRFL: 0.60, 95% CI: 0.53, 0.67). The telomere-mortality association was stronger in years 3-4 than...

  16. Structural and effective connectivity in focal epilepsy

    Directory of Open Access Journals (Sweden)

    Christopher S. Parker

    2018-01-01

    Full Text Available Patients with medically-refractory focal epilepsy may be candidates for neurosurgery and some may require placement of intracranial EEG electrodes to localise seizure onset. Assessing cerebral responses to single pulse electrical stimulation (SPES may give diagnostically useful data. SPES produces cortico-cortical evoked potentials (CCEPs, which infer effective brain connectivity. Diffusion-weighted images and tractography may be used to estimate structural brain connectivity. This combination provides the opportunity to observe seizure onset and its propagation throughout the brain, spreading contiguously along the cortex explored with electrodes, or non-contiguously. We analysed CCEPs and diffusion tractography in seven focal epilepsy patients and reconstructed the effective and structural brain networks. We aimed to assess the inter-modal similarity of the networks at a large scale across the cortex, the effective and structural connectivity of the ictal-onset zone, and investigate potential mechanisms of non-contiguous seizure spread. We found a significant overlap between structural and effective networks. Effective network CCEP amplitude, baseline variation, and outward connectivity was higher at ictal-onset zones, while structural connection strength within the ictal-onset zone tended to be higher. These findings support the concept of hyperexcitable cortex being associated with seizure generation. The high prevalence of structural and effective connections from the ictal-onset zone to sites of non-contiguous spread suggests that macroscopic structural and effective connections are plausible routes for non-contiguous seizure spread.

  17. Musical anhedonia after focal brain damage.

    Science.gov (United States)

    Belfi, Amy M; Evans, Erin; Heskje, Jonah; Bruss, Joel; Tranel, Daniel

    2017-03-01

    People listen to music because it is pleasurable. However, there are individual differences in the reward value of music. At the extreme low end of this continuum, individuals who derive no pleasure from music are said to have 'musical anhedonia.' Cases of acquired musical anhedonia following focal brain damage are rare, with only a handful having been reported in the scientific literature. Here, we surveyed a large sample of patients with focal brain damage to identify the frequency, specificity, and neural correlates of acquired musical anhedonia. Participants completed the Musical anhedonia Questionnaire and the Barcelona Music Reward Questionnaire (Mas-Herrero et al., 2013) to assess changes in musical enjoyment and reward following brain injury. Neuroanatomical data were analyzed with a proportional MAP-3 method to create voxelwise lesion proportion difference maps. No clear or consistent neuroanatomical correlates of musical anhedonia were identified. One patient with damage to the right-hemisphere putamen and internal capsule displayed specific and severe acquired musical anhedonia. These findings indicate that acquired musical anhedonia is very uncommon, a result which is consistent with the fact that only a small number of such cases have been reported in the literature. This rarity could have positive implications for the therapeutic potentialities of music in patients with severe neurological disorders. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. 7 CFR 29.6024 - Length.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Length. 29.6024 Section 29.6024 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Standards Definitions § 29.6024 Length. The linear measurement of cured tobacco leaves from the...

  19. Evolução do comprimento cervical uterino na gestação, avaliado pela ultra-sonografia transvaginal Changes in cervical length during pregnancy measured by transvaginal ultrasound

    Directory of Open Access Journals (Sweden)

    Reginaldo Antônio de Oliveira Freitas-Júnior

    2003-03-01

    Full Text Available OBJETIVO: analisar a evolução do comprimento cervical uterino, ao longo da gestação, avaliado por meio da ultra-sonografia transvaginal. MÉTODOS: foi realizado estudo prospectivo, longitudinal, no qual 82 gestantes hígidas foram acompanhadas desde o início da gestação, das quais 49 mantiveram o seguimento até o parto sem complicações da gravidez, sendo examinadas a cada quatro semanas, e agrupadas, conforme a paridade, em nulíparas ou com um ou mais partos anteriores. O comprimento do colo uterino foi avaliado em vista sagital pela ultra-sonografia transvaginal, com a medida linear da distância entre os orifícios cervicais interno e externo. RESULTADOS: as médias de comprimento do colo uterino, bem como os percentis 5, 25, 50, 75 e 95, em função da idade gestacional, não diferiram significativamente entre os grupos estudados (p>0.05. No intervalo entre a 20ª e a 24ª semana gestacional o comprimento cervical variou entre 28, 35 e 47,2 mm, com os percentis 5, 50 e 95, respectivamente. O comprimento cervical uterino diminuiu progressivamente ao longo da gestação normal, sendo esse encurtamento significativo após a 20ª semana de gravidez e mais expressivo após a 28ª semana (pPURPOSE: to establish a normality curve of cervical length during pregnancy measured by transvaginal ultrasonography. METHODS: we conducted a prospective, longitudinal study on 82 healthy pregnant women who were followed up from the beginning of pregnancy to delivery at four-week intervals, of whom 49 concluded the study. Patients were divided according to parity into nulliparous women and women with one or more previous deliveries. Cervical length was measured in a sagittal view by transvaginal ultrasonography, as the linear distance between internal and external cervical os. RESULTS: no significant difference was observed in mean cervical length or the 5th, 25, 50th, 75th, or 95th percentile according to gestational age between groups (p>0

  20. Full Length Research Article

    African Journals Online (AJOL)

    Administrator

    Out of the 320 male sheep examined, 87(27.2%) were infected, while 9(19.1%) of the 47 females examined were infected (Table 2). Infection varied from one abattoir to another. Age related distribution of P. cervi is shown in Table 3. Out of 356 adult sheep (>2yrs) examined, 35. Full Length Research Article. 12 ...

  1. Diagnóstico do parto pré-termo pela medida ultrassonográfica do comprimento do colo uterino Preterm labor diagnosis by sonographic measurement of the uterine cervical length

    Directory of Open Access Journals (Sweden)

    Carlos Eduardo Ferreira Novaes

    2009-10-01

    Full Text Available OBJETIVO: Medir o comprimento do colo uterino, utilizando a ultrassonografia transvaginal, em pacientes com quadro clínico compatível com ameaça de parto pré-termo, e correlacionar a medida do colo uterino, em cada caso, com a interrupção espontânea da gravidez dentro de sete dias. MATERIAIS E MÉTODOS: Foram realizados exames ultrassonográficos em 72 pacientes com quadro clínico compatível com ameaça de parto pré-termo. RESULTADOS: A sensibilidade do exame foi de 90,5%, a especificidade, de 98%, o valor preditivo positivo, de 95%, e o valor preditivo negativo, de 96%. A análise foi realizada utilizando-se a medida de 15 mm de comprimento do colo uterino como valor preditivo do parto pré-termo. CONCLUSÃO: Parece ser possível prever o parto pré-termo em pacientes com colo uterino menor que 15 mm. Tal observação poderá trazer contribuição para a administração mais oportuna de corticoides, com o intuito de acelerar a maturidade pulmonar fetal.OBJECTIVE: To measure the uterine cervical length by using transvaginal ultrasonography in patients with clinical signs compatible with preterm labor threat, and correlating each individual measurement with spontaneous pregnancy interruption within seven days. MATERIALS AND METHODS: Sonographic examinations were performed in 72 patients with clinical signs compatible with preterm labor threat. RESULTS: Sensitivity was 90.5%, specificity, 98%, positive predictive value, 95%, and negative predictive value, 96%. A standard uterine cervix length of 15 mm was considered as a predictive value for preterm labor. CONCLUSION: It seems to be possible to foresee preterm delivery in patients whose cervical length is < 15 mm. Such observation could contribute to a timely corticosteroid administration to accelerate fetal lung maturity.

  2. PHYSICS WITH A FOCAL PLANE PROTON POLARIMETER FOR HALL A AT CEBAF

    Energy Technology Data Exchange (ETDEWEB)

    Ron Gilman; F.T. Baker; Louis Bimbot; Ed Brash; Charles Glashausser; Mark Jones; Gerfried Kumbartzki; Sirish Nanda; Charles F. Perdrisat; Vina Punjabi; Ronald Ransome; Paul Rutt

    1994-09-01

    A focal plane polarimeter intended for the CEBAF Hall A high resolution hadron spectrometer is under construction at Rutgers University and the College of William and Mary. Experiments with focal plane polarimeters are only now beginning at electron accelerators; they play a prominent role in the list of approved experiments for Hall A. Construction of the polarimeter is in progress, it is expected to be brought to CEBAF in spring 1995. Several coincidence (e,e'p) and singles (gamma, p) measurements by the Hall A Collaboration are expected to start in 1996. In this paper we describe the polarimeter and the physics program planned for it.

  3. Spatial characterization of the internal gas target at the ESR for the FOCAL experiment

    Science.gov (United States)

    Gassner, T.; Beyer, H. F.

    2015-11-01

    The FOCAL experiment involves a highly accurate twin crystal spectrometer, designed for the measurement of the ground state Lamb shift of stored highly charged ions, like hydrogen-like Au78+, via spectroscopy in the hard-x-ray regime with an accuracy down to the few-eV level where higher-order QED contributions become accessible. For this level of accuracy all geometrical parameters including the position of the x-ray source are of crucial importance. In this conference proceeding we present our efforts to characterize the internal gas target at the experiment storage ring at GSI Darmstadt where in 2012 the FOCAL experiment was conducted.

  4. CT appearance of focal fatty infiltration of the liver

    International Nuclear Information System (INIS)

    Halvorsen, R.A.; Korobkin, M.; Ram, P.C.; Thompson, W.M.

    1982-01-01

    Focal fatty infiltration of the liver is an entity that may be confused with liver metastasis on computed tomography (CT). The imaging results and medical records of 16 patients with CT appearance suggestive of focal fatty liver were reviewed, three of whom had the simultaneous presence of metastitic liver disease. Focal fatty liver often has a distinctive appearance with CT, usually with a nonspherical shape, absence of mass effect, and density close to water. Liver metastases are usually round or oval, and unless cystic or necrotic, they have CT attenuation values closer to normal liver parenchyma than water. A radionuclide liver scan almost always resolves any confusion about the differential diagnosis of focal fatty liver: a well defined focus of photon deficiency is due to neoplasm rather than focal fatty infiltration. Sonography sometimes helps to confirm the CT impression, but may be misleading if the diagnosis of focal or diffuse fatty infiltration is not suspected before the examination

  5. Improvement of the focal-plane detector system for medium heavy ions

    International Nuclear Information System (INIS)

    Wan Yude; Li Zhongzhen

    1992-01-01

    An improved medium heavy ion focal-plane detector system (500 mm long) was tested with beam and has been used in nuclear physics experiment. The measured results at tandem accelerator with 66 MeV 12 C beam are: the energy resolution of the residual energy E detector is about 7%. The experiment of particle discrimination has been performed

  6. Physical Activity Performance of Focal Middle School Students

    Science.gov (United States)

    Erfle, Stephen E.; Gelbaugh, Corey M.

    2013-01-01

    Histograms of push-ups and curl-ups from a sample of more than 9,000 students show periodic spikes at five and 10 unit intervals. This article argues that these spikes are related to focal points, a game theoretic concept popularized by Nobel Laureate Thomas Schelling. Being focal on one test makes one more likely to be focal on the other. Focal…

  7. Sorghum cobalt analysis on not determined wave length with atomic ...

    African Journals Online (AJOL)

    This study was to know the better wave length on measuring cobalt content in forage sorghum hybrid (Sorghum bicolor) with an atomic absorption spectrophotometer. The analysis was on background correction mode with three wave lengths; 240.8, 240.7 (determined wave length or recommended wave length) and 240.6 ...

  8. [A focused sound field measurement system by LabVIEW].

    Science.gov (United States)

    Jiang, Zhan; Bai, Jingfeng; Yu, Ying

    2014-05-01

    In this paper, according to the requirement of the focused sound field measurement, a focused sound field measurement system was established based on the LabVIEW virtual instrument platform. The system can automatically search the focus position of the sound field, and adjust the scanning path according to the size of the focal region. Three-dimensional sound field scanning time reduced from 888 hours in uniform step to 9.25 hours in variable step. The efficiency of the focused sound field measurement was improved. There is a certain deviation between measurement results and theoretical calculation results. Focal plane--6 dB width difference rate was 3.691%, the beam axis--6 dB length differences rate was 12.937%.

  9. Absolute and relative-rate measurement of the rate coefficient for reaction of perfluoro ethyl vinyl ether (C2F5OCF[double bond, length as m-dash]CF2) with OH.

    Science.gov (United States)

    Srinivasulu, G; Bunkan, A J C; Amedro, D; Crowley, J N

    2018-01-31

    The rate coefficient (k 1 ) for the reaction of OH radicals with perfluoro ethyl vinyl ether (PEVE, C 2 F 5 OCF[double bond, length as m-dash]CF 2 ) has been measured as a function of temperature (T = 207-300 K) using the technique of pulsed laser photolysis with detection of OH by laser-induced fluorescence (PLP-LIF) at pressures of 50 or 100 Torr N 2 bath gas. In addition, the rate coefficient was measured at 298 K and in one atmosphere of air by the relative-rate technique with loss of PEVE and reference reactant monitored in situ by IR absorption spectroscopy. The rate coefficient has a negative temperature dependence which can be parameterized as: k 1 (T) = 6.0 × 10 -13  exp[(480 ± 38/T)] cm 3 molecule -1 s -1 and a room temperature value of k 1 (298 K) = (3.0 ± 0.3) × 10 -12 cm 3 molecule -1 s -1 . Highly accurate rate coefficients from the PLP-LIF experiments were achieved by optical on-line measurements of PEVE and by performing the measurements at two different apparatuses. The large rate coefficient and the temperature dependence indicate that the reaction proceeds via OH addition to the C[double bond, length as m-dash]C double bond, the high pressure limit already being reached at 50 Torr N 2 . Based on the rate coefficient and average OH levels, the atmospheric lifetime of PEVE was estimated to be a few days.

  10. Smart trigger logic for focal plane arrays

    Science.gov (United States)

    Levy, James E; Campbell, David V; Holmes, Michael L; Lovejoy, Robert; Wojciechowski, Kenneth; Kay, Randolph R; Cavanaugh, William S; Gurrieri, Thomas M

    2014-03-25

    An electronic device includes a memory configured to receive data representing light intensity values from pixels in a focal plane array and a processor that analyzes the received data to determine which light values correspond to triggered pixels, where the triggered pixels are those pixels that meet a predefined set of criteria, and determines, for each triggered pixel, a set of neighbor pixels for which light intensity values are to be stored. The electronic device also includes a buffer that temporarily stores light intensity values for at least one previously processed row of pixels, so that when a triggered pixel is identified in a current row, light intensity values for the neighbor pixels in the previously processed row and for the triggered pixel are persistently stored, as well as a data transmitter that transmits the persistently stored light intensity values for the triggered and neighbor pixels to a data receiver.

  11. Focal epilepsy in the Belgian shepherd

    DEFF Research Database (Denmark)

    Berendt, Mette; Gulløv, Christina Hedal; Fredholm, Merete

    2009-01-01

    OBJECTIVES: To establish the mode of inheritance and describe the clinical features of epilepsy in the Belgian shepherd, taking the outset in an extended Danish dog family (199 individuals) of Groenendael and Tervueren with accumulated epilepsy. METHODS: Epilepsy positive individuals (living...... and deceased) were ascertained through a telephone interview using a standardised questionnaire regarding seizure history and phenomenology. Living dogs were invited to a detailed clinical evaluation. Litters more than five years of age, or where epilepsy was present in all offspring before the age of five......, were included in the calculations of inheritance. results: Out of 199 family members, 66 dogs suffered from epilepsy. The prevalence of epilepsy in the family was 33%. Fifty-five dogs experienced focal seizures with or without secondary generalisation, while four dogs experienced primary generalised...

  12. Idiopathic focal segmental glomerulosclerosis and HLA antigens

    Directory of Open Access Journals (Sweden)

    M. Gerbase-DeLima

    1998-03-01

    Full Text Available The objective of the present study was to investigate a possible association between HLA class II antigens and idiopathic focal segmental glomerulosclerosis (FSGS. HLA-A, -B, -DR and -DQ antigens were determined in 19 Brazilian patients (16 white subjects and three subjects of Japanese origin with biopsy-proven FSGS. Comparison of the HLA antigen frequencies between white patients and white local controls showed a significant increase in HLA-DR4 frequency among FSGS patients (37.7 vs 17.2%, P<0.05. In addition, the three patients of Japanese extraction, not included in the statistical analysis, also presented HLA-DR4. In conclusion, our data confirm the association of FSGS with HLA-DR4 previously reported by others, thus providing further evidence for a role of genes of the HLA complex in the susceptibility to this disease

  13. Focal pachygyria with unusual vascular anomaly.

    Science.gov (United States)

    Watanabe, M; Tanaka, R; Takeda, N; Ikuta, F; Oyanagi, K

    1990-01-01

    A case of focal pachygyria with an unusual vascular anomaly is reported. Preoperative magnetic resonance imaging demonstrated few and broad gyri, and an abnormally thickened cortex of the right frontal lobe. In addition, T2-weighted imaging showed a high intensity lesion beneath the thickened cortex. In the pachygyric cortex, the peripheral portions of the arteries were tortuous and irregularly dilated, and prominent deep medullary veins were found draining into the subependymal veins. Histological examination revealed a decreased number of neurons with no tendency towards lamination, and degenerative changes with gliosis in the white matter. These findings suggest that the etiology of this anomaly may be gradual perfusion failure restricted to the territory of the anomalous vessels through the period of neuronal migration to the post-migratory, perinatal stage.

  14. THE IMAGING PROPERTIES OF THE GAS PIXEL DETECTOR AS A FOCAL PLANE POLARIMETER

    International Nuclear Information System (INIS)

    Fabiani, S.; Costa, E.; Del Monte, E.; Muleri, F.; Soffitta, P.; Rubini, A.; Bellazzini, R.; Brez, A.; De Ruvo, L.; Minuti, M.; Pinchera, M.; Sgró, C.; Spandre, G.; Spiga, D.; Tagliaferri, G.; Pareschi, G.; Basso, S.; Citterio, O.; Burwitz, V.; Burkert, W.

    2014-01-01

    X-rays are particularly suited to probing the physics of extreme objects. However, despite the enormous improvements of X-ray astronomy in imaging, spectroscopy, and timing, polarimetry remains largely unexplored. We propose the photoelectric polarimeter Gas Pixel Detector (GPD) as a candidate instrument to fill the gap created by more than 30 yr without measurements. The GPD, in the focus of a telescope, will increase the sensitivity of orders of magnitude. Moreover, since it can measure the energy, the position, the arrival time, and the polarization angle of every single photon, it allows us to perform polarimetry of subsets of data singled out from the spectrum, the light curve, or an image of the source. The GPD has an intrinsic, very fine imaging capability, and in this work we report on the calibration campaign carried out in 2012 at the PANTER X-ray testing facility of the Max-Planck-Institut für extraterrestrische Physik of Garching (Germany) in which, for the first time, we coupled it with a JET-X optics module with a focal length of 3.5 m and an angular resolution of 18 arcsec at 4.5 keV. This configuration was proposed in 2012 aboard the X-ray Imaging Polarimetry Explorer (XIPE) in response to the ESA call for a small mission. We derived the imaging and polarimetric performance for extended sources like pulsar wind nebulae and supernova remnants as case studies for the XIPE configuration and also discuss possible improvements by coupling the detector with advanced optics that have a finer angular resolution and larger effective areas to study extended objects with more detail

  15. MEG-based imaging of focal neuronal current sources

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, J.W.; Leahy, R.M. [University of Southern California, Los Angeles, CA (United States); Mosher, J.C. [Los Alamos National Lab., NM (United States)

    1996-07-01

    We describe a new approach to imaging neuronal current sources from measurements of the magnetoencephalogram (MEG) associated with sensory, motor, or cognitive brain activation. Previous approaches to this problem have concentrated on the use of weighted minimum norm inverse methods. While these methods ensure a unique solution, they do not introduce information specific to the MEG inverse problem, often producing overly smoothed solutions and exhibiting severe sensitivity to noise. We describe a Bayesian formulation of the inverse problem in which a Gibbs prior is constructed to reflect the sparse focal nature of neuronal current sources associated with evoked response data. The prior involves a binary process indicating active sources and a continuous Gaussian process designating associated amplitudes. An estimate of the primary current source distribution for a specific data set is formed by maximizing over the posterior probability with respect to the binary and continuous variables.

  16. Pharmacological response of systemically derived focal epileptic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Remler, M.P.; Sigvardt, K.; Marcussen, W.H.

    1986-11-01

    Focal epileptic lesions were made in rats by systemic focal epileptogenesis. In this method, a focal lesion of the blood-brain barrier (BBB) is produced by focal alpha irradiation followed by repeated systemic injection of a convulsant drug that cannot cross the normal BBB, resulting in a chronic epileptic focus. Changes in the spike frequency of these foci in response to various drugs was recorded. The controls, saline and chlorpromazine, produced no change. Phenytoin, phenobarbital, chlordiazepoxide, and valproic acid produced the expected decrease in spike frequency. Pentobarbital and diazepam produced a paradoxical increase in spike frequency.

  17. CT findings of focal organizing pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jun Gyun; Yoon, Sang Wook; Nam, Ji Eun; Choe, Kyu Ok; Kim, Hyoung Jung; Lee, Du Yon; Kim, Sang Jin [Yonsei Univ. College of Medicine, Seoul (Korea, Republic of); Ryu, Young Hoon [Gil General Hospital, Seoul (Korea, Republic of); Ryu, Suk Jong [Inje Univ. College of Medicine, Pusan (Korea, Republic of)

    2000-12-01

    Focal organizing pneumonia (FOP) is a benign condition which is often difficult to differentiate from bronchogenic carcinoma, and many patients with FOP undergo invasive procedures. We tried to determine which CT features might help provide a confident diagnosis of FOP. We retrospectively reviewed the medical records, chest radiographs and CT scans of 13 patients with histopathologically proven FOP. Initial chest radiographs in all 13 suggested bronchogenic carcinoma. The CT scans were reviewed by three radiologists, and final decisions were reached by consensus. They were analyzed in terms of the size, shape, contour and localization of the lesion, interior characteristics of the nodule, changes in surrounding structures, and changes in any of these findings, as revealed by follow-up chest CT scanning. FOP lesions were oval or triangular in shape and between 1.8 and 6.5cm in their largest diameter. All had irregular margins and all but one were peripherally located. Eight (61.5%) were in contact with the pleura and five (38.5%) were located along the peripheral bronchovascular bundle, with pleural indentation; in eight (61.5%), post-contrast CT scanning revealed inhomogeneous enhancement, and four (30.8%) had pleural tags. In five (38.5%), there was coarse spiculation; for six (46.2%), air bronchograms were available, and in four (30.8%), satellite nodules were present. Spotty calcification and lymph node enlargement were each evident in one case only. Follow-up CT scanning, available in four cases, showed that the mass decreased in size in three and disappeared completely in one. Although there were no consistent CT features for differentiating focal organizing pneumonia from lung cancer, the possibility of the former should be considered when a peripherally-located oval or triangular-shaped mass is in broad contact with the pleura or is located along the bronchovascular bundle, and satellite nodules are also present.

  18. Focal cryotherapy: step by step technique description.

    Science.gov (United States)

    Redondo, Cristina; Srougi, Victor; da Costa, José Batista; Baghdad, Mohammed; Velilla, Guillermo; Nunes-Silva, Igor; Bergerat, Sebastien; Garcia-Barreras, Silvia; Rozet, François; Ingels, Alexandre; Galiano, Marc; Sanchez-Salas, Rafael; Barret, Eric; Cathelineau, Xavier

    2017-01-01

    Focal cryotherapy emerged as an efficient option to treat favorable and localized prostate cancer (PCa). The purpose of this video is to describe the procedure step by step. We present the case of a 68 year-old man with localized PCa in the anterior aspect of the prostate. The procedure is performed under general anesthesia, with the patient in lithotomy position. Briefly, the equipament utilized includes the cryotherapy console coupled with an ultrasound system, argon and helium gas bottles, cryoprobes, temperature probes and an urethral warming catheter. The procedure starts with a real-time trans-rectal prostate ultrasound, which is used to outline the prostate, the urethra and the rectal wall. The cryoprobes are pretested and placed in to the prostate through the perineum, following a grid template, along with the temperature sensors under ultrasound guidance. A cystoscopy confirms the right positioning of the needles and the urethral warming catheter is installed. Thereafter, the freeze sequence with argon gas is started, achieving extremely low temperatures (-40ºC) to induce tumor cell lysis. Sequentially, the thawing cycle is performed using helium gas. This process is repeated one time. Results among several series showed a biochemical disease-free survival between 71-93% at 9-70 month- follow-up, incontinence rates between 0-3.6% and erectile dysfunction between 0-42% (1-5). Focal cryotherapy is a feasible procedure to treat anterior PCa that may offer minimal morbidity, allowing good cancer control and better functional outcomes when compared to whole-gland treatment. Copyright® by the International Brazilian Journal of Urology.

  19. Focal cryotherapy: step by step technique description

    Directory of Open Access Journals (Sweden)

    Cristina Redondo

    Full Text Available ABSTRACT Introduction and objective: Focal cryotherapy emerged as an efficient option to treat favorable and localized prostate cancer (PCa. The purpose of this video is to describe the procedure step by step. Materials and methods: We present the case of a 68 year-old man with localized PCa in the anterior aspect of the prostate. Results: The procedure is performed under general anesthesia, with the patient in lithotomy position. Briefly, the equipment utilized includes the cryotherapy console coupled with an ultrasound system, argon and helium gas bottles, cryoprobes, temperature probes and an urethral warming catheter. The procedure starts with a real-time trans-rectal prostate ultrasound, which is used to outline the prostate, the urethra and the rectal wall. The cryoprobes are pretested and placed in to the prostate through the perineum, following a grid template, along with the temperature sensors under ultrasound guidance. A cystoscopy confirms the right positioning of the needles and the urethral warming catheter is installed. Thereafter, the freeze sequence with argon gas is started, achieving extremely low temperatures (-40°C to induce tumor cell lysis. Sequentially, the thawing cycle is performed using helium gas. This process is repeated one time. Results among several series showed a biochemical disease-free survival between 71-93% at 9-70 month- follow-up, incontinence rates between 0-3.6% and erectile dysfunction between 0-42% (1–5. Conclusions: Focal cryotherapy is a feasible procedure to treat anterior PCa that may offer minimal morbidity, allowing good cancer control and better functional outcomes when compared to whole-gland treatment.

  20. Gap length distributions by PEPR

    International Nuclear Information System (INIS)

    Warszawer, T.N.

    1980-01-01

    Conditions guaranteeing exponential gap length distributions are formulated and discussed. Exponential gap length distributions of bubble chamber tracks first obtained on a CRT device are presented. Distributions of resulting average gap lengths and their velocity dependence are discussed. (orig.)

  1. Uniquely identifying cell orientation and sarcomere length in the intact rodent heart with oblique plane remote focussing microscopy

    Science.gov (United States)

    Corbett, A. D.; Burton, R. A. B.; Bub, G.; Wilson, T.

    2015-07-01

    In cardiac imaging, the spacing between sub-cellular sarcomere structures is of great importance to physiologists in understanding muscle design and performance. Making accurate measurements of the sarcomere length (SL) presents a significant imaging challenge owing to the size of the SL (~2μm) and its naturally low variability (pathological models of chronic hypertension. As well as improving measurement precision, the distribution of α across the field of view provides additional structural information which can be related to disease morphology. To validate this new imaging protocol, the value of α calculated from the oblique planes provided the input to a rigid model cell which was used to predict the appearance of the cell in the conventional focal plane. The comparison of the model to the image data provided a confidence metric for our measurements. Finally, by considering the optical transfer function, the range of cell orientations for which the method is valid could be calculated.

  2. Length of excitable knots

    Science.gov (United States)

    Maucher, Fabian; Sutcliffe, Paul

    2017-07-01

    In this paper, we present extensive numerical simulations of an excitable medium to study the long-term dynamics of knotted vortex strings for all torus knots up to crossing number 11. We demonstrate that FitzHugh-Nagumo evolution preserves the knot topology for all the examples presented, thereby providing a field theory approach to the study of knots. Furthermore, the evolution yields a well-defined minimal length for each knot that is comparable to the ropelength of ideal knots. We highlight the role of the medium boundary in stabilizing the length of the knot and discuss the implications beyond torus knots. We also show that there is not a unique attractor within a given knot topology.

  3. Pion nucleus scattering lengths

    International Nuclear Information System (INIS)

    Huang, W.T.; Levinson, C.A.; Banerjee, M.K.

    1971-09-01

    Soft pion theory and the Fubini-Furlan mass dispersion relations have been used to analyze the pion nucleon scattering lengths and obtain a value for the sigma commutator term. With this value and using the same principles, scattering lengths have been predicted for nuclei with mass number ranging from 6 to 23. Agreement with experiment is very good. For those who believe in the Gell-Mann-Levy sigma model, the evaluation of the commutator yields the value 0.26(m/sub σ//m/sub π/) 2 for the sigma nucleon coupling constant. The large dispersive corrections for the isosymmetric case implies that the basic idea behind many of the soft pion calculations, namely, slow variation of matrix elements from the soft pion limit to the physical pion mass, is not correct. 11 refs., 1 fig., 3 tabs

  4. Aromatase and neuroinflammation in rat focal brain ischemia.

    Science.gov (United States)

    Zhong, Yu H; Dhawan, Jasbeer; Kovoor, Joel A; Sullivan, John; Zhang, Wei X; Choi, Dennis; Biegon, Anat

    2017-11-01

    Accumulating evidence suggests that expression of aromatase, the enzyme responsible for the conversion of androgens to estrogens, is transiently upregulated in rat stroke models. It was further suggested that increased aromatase expression is linked to neuroinflammation and that it is neuroprotective in females. Our goal was to investigate aromatase upregulation in male rats subjected to experimental stroke in relationship to neuroinflammation, infarct and response to treatment with different putative neuroprotective agents. Intact male rats were subjected to transient (90min) middle cerebral artery occlusion (MCAO) and administered selfotel (N-methyl-d-aspartic acid (NMDA) receptor competitive antagonist), TPEN (a zinc chelator), a combination of the two drugs or vehicle, injected immediately after reperfusion. Animals were killed 14days after MCAO and consecutive brain sections used to measure aromatase expression, cerebral infarct volume and neuroinflammation. Quantitative immunohistochemistry (IHC) demonstrated increased brain aromatase expression in the peri-infarct area relative to contralesional area, which was partially abrogated by neuroprotective agents. There was no correlation between aromatase expression in the peri-infarct zone and infarct volume, which was reduced by neuroprotective agents. Microglial activation, measured by quantitative autoradiography, was positively correlated with infarct and inversely correlated with aromatase expression in the peri-infarct zone. Our findings indicate that focal ischemia upregulates brain aromatase in the male rat brain at 14days post surgery, which is within the time frame documented in females. However, the lack of negative correlation between aromatase expression and infarct volume and lack of positive correlation between microgliosis and aromatase do not support a major role for aromatase as a mediator of neuroprotection or a causal relationship between microglial activation and increased aromatase

  5. Length-weight and length-length relationships of freshwater wild ...

    African Journals Online (AJOL)

    Length-weight and length-length relationships of freshwater wild catfish Mystus bleekeri from Nala Daik, Sialkot, Pakistan. ... Linear regression analysis was used, first to compute the degree of relationship between length and weight and then among total (TL), standard (SL) and fork lengths (FL). LWR exhibited a highly ...

  6. Relativistic length agony continued

    Directory of Open Access Journals (Sweden)

    Redžić D.V.

    2014-01-01

    Full Text Available We made an attempt to remedy recent confusing treatments of some basic relativistic concepts and results. Following the argument presented in an earlier paper (Redžić 2008b, we discussed the misconceptions that are recurrent points in the literature devoted to teaching relativity such as: there is no change in the object in Special Relativity, illusory character of relativistic length contraction, stresses and strains induced by Lorentz contraction, and related issues. We gave several examples of the traps of everyday language that lurk in Special Relativity. To remove a possible conceptual and terminological muddle, we made a distinction between the relativistic length reduction and relativistic FitzGerald-Lorentz contraction, corresponding to a passive and an active aspect of length contraction, respectively; we pointed out that both aspects have fundamental dynamical contents. As an illustration of our considerations, we discussed briefly the Dewan-Beran-Bell spaceship paradox and the ‘pole in a barn’ paradox. [Projekat Ministarstva nauke Republike Srbije, br. 171028

  7. Acute focal nephritis. Echographic diagnostic by computerized Tomography. Nefritis aguda focal. Diagnostico ecografico por TC

    Energy Technology Data Exchange (ETDEWEB)

    Castaner, F.; Gomez-Martinech, E.; Ferrer, J.; Barcelo, J.; LLado, I.; Pont, J.

    1991-01-01

    Radiologic findings of four cases of acute focal nephritis and their clinical correlation are presented. They were studied by means of echography and computerized tomography (CT). The latter was the technique of choice for their diagnosis in the study carried out after intravenous radiopaque contrast injection because of its sensitivity and specificity. The literature on this topic is reviewed and some guidelines for diagnosis and differential diagnosis are proposed. (Author)

  8. The length of the male urethra

    Directory of Open Access Journals (Sweden)

    Tobias. S. Kohler

    2008-08-01

    Full Text Available PURPOSE: Catheter-based medical devices are an important component of the urologic armamentarium. To our knowledge, there is no population-based data regarding normal male urethral length. We evaluated the length of the urethra in men with normal genitourinary anatomy undergoing either Foley catheter removal or standard cystoscopy. MATERIALS AND METHODS: Male urethral length was obtained in 109 men. After study permission was obtained, the subject's penis was placed on a gentle stretch and the catheter was marked at the tip of the penis. The catheter was then removed and the distance from the mark to the beginning of the re-inflated balloon was measured. Alternatively, urethral length was measured at the time of cystoscopy, on removal of the cystoscope. Data on age, weight, and height was obtained in patients when possible. RESULTS: The mean urethral length was 22.3 cm with a standard deviation of 2.4 cm. Urethral length varied between 15 cm and 29 cm. No statistically significant correlation was found between urethral length and height, weight, body mass index (BMI, or age. CONCLUSIONS: Literature documenting the length of the normal male adult urethra is scarce. Our data adds to basic anatomic information of the male urethra and may be used to optimize genitourinary device design.

  9. Intersubunit distances in full-length, dimeric, bacterial phytochrome Agp1, as measured by pulsed electron-electron double resonance (PELDOR) between different spin label positions, remain unchanged upon photoconversion.

    Science.gov (United States)

    Kacprzak, Sylwia; Njimona, Ibrahim; Renz, Anja; Feng, Juan; Reijerse, Edward; Lubitz, Wolfgang; Krauss, Norbert; Scheerer, Patrick; Nagano, Soshichiro; Lamparter, Tilman; Weber, Stefan

    2017-05-05

    Bacterial phytochromes are dimeric light-regulated histidine kinases that convert red light into signaling events. Light absorption by the N-terminal photosensory core module (PCM) causes the proteins to switch between two spectrally distinct forms, Pr and Pfr, thus resulting in a conformational change that modulates the C-terminal histidine kinase region. To provide further insights into structural details of photoactivation, we investigated the full-length Agp1 bacteriophytochrome from the soil bacterium Agrobacterium fabrum using a combined spectroscopic and modeling approach. We generated seven mutants suitable for spin labeling to enable application of pulsed EPR techniques. The distances between attached spin labels were measured using pulsed electron-electron double resonance spectroscopy to probe the arrangement of the subunits within the dimer. We found very good agreement of experimental and calculated distances for the histidine-kinase region when both subunits are in a parallel orientation. However, experimental distance distributions surprisingly showed only limited agreement with either parallel- or antiparallel-arranged dimer structures when spin labels were placed into the PCM region. This observation indicates that the arrangements of the PCM subunits in the full-length protein dimer in solution differ significantly from that in the PCM crystals. The pulsed electron-electron double resonance data presented here revealed either no or only minor changes of distance distributions upon Pr-to-Pfr photoconversion. © 2017 by The American Society for Biochemistry and Molecular Biology, Inc.

  10. In vitro phosphorylation of the focal adhesion targeting domain of focal adhesion kinase by Src kinase.

    Science.gov (United States)

    Cable, Jennifer; Prutzman, Kirk; Gunawardena, Harsha P; Schaller, Michael D; Chen, Xian; Campbell, Sharon L

    2012-03-20

    Focal adhesion kinase (FAK), a key regulator of cell adhesion and migration, is overexpressed in many types of cancer. The C-terminal focal adhesion targeting (FAT) domain of FAK is necessary for proper localization of FAK to focal adhesions and subsequent activation. Phosphorylation of Y926 in the FAT domain by the tyrosine kinase Src has been shown to promote metastasis and invasion in vivo by linking the FAT domain to the MAPK pathway via its interaction with growth factor receptor-bound protein 2. Several groups have reported that inherent conformational dynamics in the FAT domain likely regulate phosphorylation of Y926; however, what regulates these dynamics is unknown. In this paper, we demonstrate that there are two sites of in vitro Src-mediated phosphorylation in the FAT domain: Y926, which has been shown to affect FAK function in vivo, and Y1008, which has no known biological role. The phosphorylation of these two tyrosine residues is pH-dependent, but this does not reflect the pH dependence of Src kinase activity. Circular dichroism and nuclear magnetic resonance data indicate that the stability and conformational dynamics of the FAT domain are sensitive to changes in pH over a physiological pH range. In particular, regions of the FAT domain previously shown to regulate phosphorylation of Y926 as well as regions near Y1008 show pH-dependent dynamics on the microsecond to millisecond time scale.

  11. MRI in assessing children with learning disability, focal findings, and reduced automaticity.

    Science.gov (United States)

    Urion, David K; Huff, Hanalise V; Carullo, Maria Paulina

    2015-08-18

    In children with clinically diagnosed learning disabilities with focal findings on neurologic or neuropsychological evaluations, there is a hypothesized association between disorders in automaticity and focal structural abnormalities observed in brain MRIs. We undertook a retrospective analysis of cases referred to a tertiary-hospital-based learning disabilities program. Individuals were coded as having a focal deficit if either neurologic or neuropsychological evaluation demonstrated focal dysfunction. Those with abnormal MRI findings were categorized based on findings. Children with abnormalities from each of these categories were compared in terms of deficits in automaticity, as measured by the tasks of Rapid Automatized Naming, Rapid Alternating Stimulus Naming, or the timed motor performance battery from the Physical and Neurological Examination for Soft Signs. Data were compared in children with and without disorders of automaticity regarding type of brain structure abnormality. Of the 1,587 children evaluated, 127 had a focal deficit. Eighty-seven had a brain MRI (52 on 1.5-tesla machines and 35 on 3.0-tesla machines). Forty of these images were found to be abnormal. These children were compared with a clinic sample of 150 patients with learning disabilities and no focal findings on examination, who also had undergone MRI. Only 5 of the latter group had abnormalities on MRI. Reduced verbal automaticity was associated with cerebellar abnormalities, whereas reduced automaticity on motor or motor and verbal tasks was associated with white matter abnormalities. Reduced automaticity of retrieval and slow timed motor performance appear to be highly associated with MRI findings. © 2015 American Academy of Neurology.

  12. Dual focal-spot imaging for phase extraction in phase-contrast radiography

    International Nuclear Information System (INIS)

    Donnelly, Edwin F.; Price, Ronald R.; Pickens, David R.

    2003-01-01

    The purpose of this study was to evaluate dual focal spot imaging as a method for extracting the phase component from a phase-contrast radiography image. All measurements were performed using a microfocus tungsten-target x-ray tube with an adjustable focal-spot size (0.01 mm to 0.045 mm). For each object, high-resolution digital radiographs were obtained with two different focal spot sizes to produce matched image pairs in which all other geometric variables as well as total exposure and tube kVp were held constant. For each image pair, a phase extraction was performed using pixel-wise division. The phase-extracted image resulted in an image similar to the standard image processing tool commonly referred to as 'unsharp masking' but with the additional edge-enhancement produced by phase-contrast effects. The phase-extracted image illustrates the differences between the two images whose imaging parameters differ only in focal spot size. The resulting image shows effects from both phase contrast as well as geometric unsharpness. In weakly attenuating materials the phase-contrast effect predominates, while in strongly attenuating materials the phase effects are so small that they are not detectable. The phase-extracted image in the strongly attenuating object reflects differences in geometric unsharpness. The degree of phase extraction depends strongly on the size of the smallest focal spot used. This technique of dual-focal spot phase-contrast radiography provides a simple technique for phase-component (edge) extraction in phase-contrast radiography. In strongly attenuating materials the phase-component is overwhelmed by differences in geometric unsharpness. In these cases the technique provides a form of unsharp masking which also accentuates the edges. Thus, the two effects are complimentary and may be useful in the detection of small objects

  13. Short cervical length dilemma.

    Science.gov (United States)

    Suhag, Anju; Berghella, Vincenzo

    2015-06-01

    Preterm birth (PTB) is a leading cause of neonatal morbidity and mortality. With research efforts, the rate of PTB decreased to 11.4% in 2013. Transvaginal ultrasound (TVU) cervical length (CL) screening predicts PTB. In asymptomatic singletons without prior spontaneous PTB (sPTB), TVU CL screening should be done. If the cervix is 20 mm or less, vaginal progesterone is indicated. In asymptomatic singletons with prior sPTB, serial CL screening is indicated. In multiple gestations, routine cervical screening is not indicated. In symptomatic women with preterm labor, TVU CL screening and fetal fibronectin testing is recommended. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Primary length standard adjustment

    Science.gov (United States)

    Ševčík, Robert; Guttenová, Jana

    2007-04-01

    This paper deals with problems and techniques connected with primary length standard adjusting, which includes disassembling of the device and by use of the secondary laser with collimated beam and diffraction laws successively reassembling of the laser. In the reassembling process the device was enhanced with substituting the thermal grease cooling of cold finger by copper socket cooler. This improved external cooling system enables more effective cooling of molecular iodine in the cell, which allows better pressure stability of iodine vapor and easier readjustment of the system.

  15. uper-resolution Axial Localization of Ultrasound Scatter Using Multi-focal Imaging

    DEFF Research Database (Denmark)

    Diamantis, Konstantinos; Greenaway, Alan H.; Anderson, Tom

    2017-01-01

    to noise ratio in each image. Conclusion: Super-resolution axial imaging from optical microscopy has been successfully translated into ultrasound imaging by using raw ultrasound data and standard beamforming. Significance: The normalized sharpness method has the potential to be used in scatterer...... localization applications and contribute in current super-resolution ultrasound imaging techniques.......This paper aims to develop a method for achieving micrometre axial scatterer localization for medical ultrasound, surpassing the inherent, pulse length dependence limiting ultrasound imaging. Methods: The method, directly translated from cellular microscopy, is based on multi-focal imaging...

  16. Radiologic manifestations of focal cerebral hyperemia in acute stroke

    DEFF Research Database (Denmark)

    Olsen, Tom Skyhøj; Skriver, E B; Herning, M

    1991-01-01

    In 16 acute stroke patients with focal cerebral hyperemia angiography and regional cerebral blood flow (rCBF) were studied 1 to 4 days post stroke. CT was performed twice with and without contrast enhancement 3 +/- 1 days and 16 +/- 4 days post stroke. Angiographic evidence of focal cerebral hype...

  17. Proximal Focal Femoral Deficiency in Ibadan a Developing ...

    African Journals Online (AJOL)

    The cultural aversion to amputation in our environment makes it difficult to employ that option of treatment. Proximal focal femoral deficiency in Ibadan a developing country's perspective and a review of the literature. Keywords: Proximal focal femoral deficiency , congenital malformations , limb malformations , lower limb ...

  18. Concordance of MRI and EEG Focal Slowing in Nonsyndromic Epilepsy

    Directory of Open Access Journals (Sweden)

    J Gordon Millichap

    2013-04-01

    Full Text Available Investigators at the Kangwon National University, Korea, and The Epilepsy Center, Lurie Children’s Hospital of Chicago, USA studied the correlation and significance of EEG focal slowing and focal MRI abnormalities in 253 children with nonsyndromic epilepsy.

  19. Contrast enhanced ultrasound in CT-undetermined focal liver lesions

    DEFF Research Database (Denmark)

    Sandrose, Sebastian; Karstrup, S.; Gerke, Oke

    2016-01-01

    Purpose: The purpose of this study was to examine the diagnostic accuracy of CEUS in the diagnosis of focal liver lesions, which were undetermined at CT scan. Materials and Methods: From January 2010 to December 2010, patients with CT-undetermined focal liver lesions were included in this study...

  20. [Color Doppler sonography of focal abdominal lesions].

    Science.gov (United States)

    Licanin, Zoran; Lincender, Lidija; Djurović, V; Salihefendić, Nizama; Smajlović, Fahrudin

    2004-01-01

    Color Doppler sonography (CDS--spectral, color and power), harmonic imaging techniques (THI, PHI), possibility of 3D analysis of picture, usage of contrast agents, have raised the values of ultrasound as a diagnostic method to a very high level. THI--non-linear gray scale modality, is based on the processing of higher reflected frequencies, that has improved a picture resolution, which is presented with less artifacts and limiting effects of obesity and gases. Ultrasound contrast agents improve analysis of micro and macro circulation of the examined area, and with the assessment of velocity of supply in ROI (wash in), distribution and time of signal weakening (wash out), are significantly increasing diagnostic value of ultrasound. Besides the anatomical and topographic presentation of examined region (color, power), Color Doppler sonography gives us haemodynamic-functional information on vascularisation of that region, as well as on pathologic vascularisation if present. Avascular aspect of a focal pathologic lesion corresponds to a cyst or haematoma, while coloration and positive spectral curve discover that anechogenic lesions actually represents aneurysms, pseudoaneurysms or AVF. In local inflammatory lesion, abscess in an acute phase, CDS shows first increased, and then decreased central perfusion, while in a chronic phase, a pericapsular vascularisation is present. Contribution of CDS in differentiation of hepatic tumors (hemangioma, HCC and metastasis) is very significant. Central color dots along the peripheral blood vessels and the blush phenomenon are characteristics of capillary hemangioma, peritumoral vascular ring "basket" of HCC, and "detour" sign of metastasis. The central artery, RI from 0.45 to 0.60 and radial spreading characterize FNH. Hepatic adenoma is characterized by an intratumoral vein, and rarely by a vascular hallo. Further on, blood velocity in tumor defined by Color Doppler, distinguishes malignant from benign lesion, where 40 cm/s is a

  1. Inhibition of thermolysin by phosphonamidate transition-state analogues: measurement of 31P-15N bond lengths and chemical shifts in two enzyme-inhibitor complexes by solid-state nuclear magnetic resonance.

    Science.gov (United States)

    Copié, V; Kolbert, A C; Drewry, D H; Bartlett, P A; Oas, T G; Griffin, R G

    1990-10-02

    31P and 15N chemical shifts and 31P-15N bond lengths have been measured with solid-state NMR techniques in two inhibitors of thermolysin, carbobenzoxy-Glyp-L-Leu-L-Ala (ZGpLA) and carbobenzoxy-L-Phep-L-Leu-L-Ala (ZFpLA), both as free lithium salts and when bound to the enzyme. Binding of both inhibitors to thermolysin results in large changes in the 31P chemical shifts. These changes are more dramatic for the tighter binding inhibitor ZFpLA, where a approximately 20 ppm downfield movement of the 31P isotropic chemical shift (sigma iso) is observed. This shift is due to changes in the shift tensor elements sigma 11 and sigma 22, while sigma 33 remains essentially constant. We observed a similar pattern for ZGpLA, but only a approximately 5 ppm change occurs in sigma iso. The changes in the 15N chemical shifts for both inhibitors are small upon binding, amounting to downfield shifts of 2 and 4 ppm for ZGpLA and ZFpLA, respectively. This indicates that there are no changes in the protonation state of the 15N in either the ZFpLA- or the ZGpLA-thermolysin complex. NMR distance measurements yield a P-N bond length rP-N = 1.68 +/- 0.03 A for the tight binding inhibitor ZFpLA both in its free lithium salt form and in its thermolysin-ZFpLA complex, a distance that is much shorter than the 1.90-A distance reported by X-ray crystallography studies [Holden et al. (1987) Biochemistry 26, 8542-8553].(ABSTRACT TRUNCATED AT 250 WORDS)

  2. Ballistic Target PHD Filter Based on Infrared Focal Plane Ambiguous Observation

    Directory of Open Access Journals (Sweden)

    Wei Zhao

    2017-01-01

    Full Text Available Space-based early warning system, the main detection means of which is passive detection based on focal plane, is an important part of ballistic missile defense system. The focal plane is mainly composed of CCD, and its size can reach the micron level, so the pixel is often regarded as point of no area in image postprocessing. The design of traditional tracking methods is based on this, and the observation based on the focal plane is modeled as the azimuth with random noise. However, this modeling is inaccurate. In the context of space-based detection, CCD cannot be simplified as a point, and its size should be considered. And the corresponding observation cannot be treated as azimuth with random noise. In this paper, the observation based on focal plane is modeled as Unambiguously Generated Ambiguous (UGA measurement. The PHD filter algorithm is redesigned and simplified. The simulation results show that the algorithm based on UGA measurement observation model has better tracking effect compared with that based on traditional observation model. This method provides technical support for more accurate target tracking for space-based early warning system.

  3. Economic issues of broiler production length

    Directory of Open Access Journals (Sweden)

    Szőllősi László

    2014-01-01

    Full Text Available The length of broiler production cycle is also an important factor when profitability is measured. This paper is to determine the effects of different market ages and down-time period, overall broiler production cycle length on performance and economic parameters based on Hungarian production and financial circumstances. A deterministic model was constructed to manage the function-like correlations of age-related daily weight gain, daily feed intake and daily mortality data. The results show that broiler production cycle length has a significant effect on production and economic performance. Cycle length is determined by the length of down-time and grow-out periods. If down-time period is reduced by one day, an average net income of EUR 0.55 per m2 is realizable. However, the production period is not directly proportional either with emerging costs or obtainable revenues. Profit maximization is attainable if the production period is 41-42 days.

  4. Cosmology Large Angular Scale Surveyor (CLASS) Focal Plane Development

    Science.gov (United States)

    Chuss, D. T.; Ali, A.; Amiri, M.; Appel, J.; Bennett, C. L.; Colazo, F.; Denis, K. L.; Dünner, R.; Essinger-Hileman, T.; Eimer, J.; Fluxa, P.; Gothe, D.; Halpern, M.; Harrington, K.; Hilton, G.; Hinshaw, G.; Hubmayr, J.; Iuliano, J.; Marriage, T. A.; Miller, N.; Moseley, S. H.; Mumby, G.; Petroff, M.; Reintsema, C.; Rostem, K.; U-Yen, K.; Watts, D.; Wagner, E.; Wollack, E. J.; Xu, Z.; Zeng, L.

    2016-08-01

    The Cosmology Large Angular Scale Surveyor (CLASS) will measure the polarization of the Cosmic Microwave Background to search for and characterize the polarized signature of inflation. CLASS will operate from the Atacama Desert and observe ˜ 70 % of the sky. A variable-delay polarization modulator provides modulation of the polarization at ˜ 10 Hz to suppress the 1/ f noise of the atmosphere and enable the measurement of the large angular scale polarization modes. The measurement of the inflationary signal across angular scales that spans both the recombination and reionization features allows a test of the predicted shape of the polarized angular power spectra in addition to a measurement of the energy scale of inflation. CLASS is an array of telescopes covering frequencies of 38, 93, 148, and 217 GHz. These frequencies straddle the foreground minimum and thus allow the extraction of foregrounds from the primordial signal. Each focal plane contains feedhorn-coupled transition-edge sensors that simultaneously detect two orthogonal linear polarizations. The use of single-crystal silicon as the dielectric for the on-chip transmission lines enables both high efficiency and uniformity in fabrication. Integrated band definition has been implemented that both controls the bandpass of the single-mode transmission on the chip and prevents stray light from coupling to the detectors.

  5. Cosmology Large Angular Scale Surveyor (CLASS) Focal Plane Development

    Science.gov (United States)

    Chuss, D. T.; Ali, A.; Amiri, M.; Appel, J.; Bennett, C. L.; Colazo, F.; Denis, K. L.; Dunner, R.; Essinger-Hileman, T.; Eimer, J.; hide

    2015-01-01

    The Cosmology Large Angular Scale Surveyor (CLASS) will measure the polarization of the Cosmic Microwave Background to search for and characterize the polarized signature of inflation. CLASS will operate from the Atacama Desert and observe approx.70% of the sky. A variable-delay polarization modulator provides modulation of the polarization at approx.10Hz to suppress the 1/f noise of the atmosphere and enable the measurement of the large angular scale polarization modes. The measurement of the inflationary signal across angular scales that spans both the recombination and reionization features allows a test of the predicted shape of the polarized angular power spectra in addition to a measurement of the energy scale of inflation. CLASS is an array of telescopes covering frequencies of 38, 93, 148, and 217 GHz. These frequencies straddle the foreground minimum and thus allow the extraction of foregrounds from the primordial signal. Each focal plane contains feedhorn-coupled transition-edge sensors that simultaneously detect two orthogonal linear polarizations. The use of single-crystal silicon as the dielectric for the on-chip transmission lines enables both high efficiency and uniformity in fabrication. Integrated band definition has been implemented that both controls the bandpass of the single-mode transmission on the chip and prevents stray light from coupling to the detectors.

  6. The dose-response of canine focal gastric mucosal blood flow to misoprostol

    International Nuclear Information System (INIS)

    Gana, T.J.; Pherson, B.R.; Koo, J.

    1989-01-01

    The dose-response of focal gastric mucosal blood flow was measured simultaneously by laser-Doppler flowmetry and hydrogen gas clearance in the canine chambered gastric segment to topical misoprostol. Simultaneously obtained mucosal blood flow values showed a highly significant linear correlation in the basal but not misoprostol periods between the two techniques. Laser-Doppler flowmetry measured a dose-dependent increase in blood flow, while in contrast, hydrogen gas clearance showed a gradual decline in blood flow after misoprostol administration throughout all experiments. It is concluded that misoprostol dose-dependently and transiently increases focal gastric mucosal blood flow. However, only laser-Doppler flowmetry is sensitive enough to detect it. Although it can measure steady-state blood flow, owing to the duration of one measurement, hydrogen gas clearance is incapable of detecting rapid flow changes

  7. The dose-response of canine focal gastric mucosal blood flow to misoprostol

    Energy Technology Data Exchange (ETDEWEB)

    Gana, T.J.; Pherson, B.R.; Koo, J. (Alberta Univ., Edmonton, AB (Canada))

    1989-01-01

    The dose-response of focal gastric mucosal blood flow was measured simultaneously by laser-Doppler flowmetry and hydrogen gas clearance in the canine chambered gastric segment to topical misoprostol. Simultaneously obtained mucosal blood flow values showed a highly significant linear correlation in the basal but not misoprostol periods between the two techniques. Laser-Doppler flowmetry measured a dose-dependent increase in blood flow, while in contrast, hydrogen gas clearance showed a gradual decline in blood flow after misoprostol administration throughout all experiments. It is concluded that misoprostol dose-dependently and transiently increases focal gastric mucosal blood flow. However, only laser-Doppler flowmetry is sensitive enough to detect it. Although it can measure steady-state blood flow, owing to the duration of one measurement, hydrogen gas clearance is incapable of detecting rapid flow changes.

  8. Fast Focal Point Correction in Prism-Coupled Total Internal Reflection Scanning Imager Using an Electronically Tunable Lens.

    Science.gov (United States)

    Zhu, Chenggang; Ge, Bilin; Chen, Ru; Zhu, Xiangdong; Mi, Lan; Ma, Jiong; Wang, Xu; Zheng, Fengyun; Fei, Yiyan

    2018-02-09

    Total internal reflection (TIR) is useful for interrogating physical and chemical processes that occur at the interface between two transparent media. Yet prism-coupled TIR imaging microscopes suffer from limited sensing areas due to the fact that the interface (the object plane) is not perpendicular to the optical axis of the microscope. In this paper, we show that an electrically tunable lens can be used to rapidly and reproducibly correct the focal length of an oblique-incidence scanning microscope (OI-RD) in a prism-coupled TIR geometry. We demonstrate the performance of such a correction by acquiring an image of a protein microarray over a scan area of 4 cm² with an effective resolution of less than 20 microns. The electronic focal length tuning eliminates the mechanical movement of the illumination lens in the scanning microscope and in turn the noise and background drift associated with the motion.

  9. Fast Focal Point Correction in Prism-Coupled Total Internal Reflection Scanning Imager Using an Electronically Tunable Lens

    Directory of Open Access Journals (Sweden)

    Chenggang Zhu

    2018-02-01

    Full Text Available Total internal reflection (TIR is useful for interrogating physical and chemical processes that occur at the interface between two transparent media. Yet prism-coupled TIR imaging microscopes suffer from limited sensing areas due to the fact that the interface (the object plane is not perpendicular to the optical axis of the microscope. In this paper, we show that an electrically tunable lens can be used to rapidly and reproducibly correct the focal length of an oblique-incidence scanning microscope (OI-RD in a prism-coupled TIR geometry. We demonstrate the performance of such a correction by acquiring an image of a protein microarray over a scan area of 4 cm2 with an effective resolution of less than 20 microns. The electronic focal length tuning eliminates the mechanical movement of the illumination lens in the scanning microscope and in turn the noise and background drift associated with the motion.

  10. Depression in focal, segmental and generalized dystonia.

    Science.gov (United States)

    Lewis, L; Butler, A; Jahanshahi, M

    2008-11-01

    Dystonia causes body disfigurement in the majority of those affected. Our aim was to test the hypothesis that low self-esteem resulting from the sense of disfigurement is an important component of self-reported depression in focal, segmental and generalized dystonia. Questionnaires to assess self-reported depression, self-esteem, body concept, disfigurement, disability and quality of life were completed by 329 community based dystonia patients. Moderate to severe depression was reported by 30 %. Self-reported depression had a strong somatic component, but patients also showed a specific concern with self-image. Extent of dystonia, body parts affected and marital status influenced self-reported depression in dystonia. Self esteem, body concept, disfigurement and quality of life emerged as factors which accounted for the variance of self-reported depression in dystonia. These results suggest that in dystonia, disfigurement, negative body concept, low self-esteem, and the impact of the disease on quality of life make important contributions to depression. However, longitudinal followup is required to firmly establish the direction of causality between depression and these psychosocial variables in dystonia.

  11. Medical image of the week: focal myopericaditis

    Directory of Open Access Journals (Sweden)

    Meenakshisundaram C

    2015-07-01

    Full Text Available No abstract available. Article truncated at 150 words. A 44-year-old man with no significant past medical history was admitted with a history of two episodes of substernal chest pain unrelated to exertion which had resolved spontaneously. Admission vital signs were within normal limits and physical examination was unremarkable. Basic lab tests were normal and urine toxicology was negative. Electrocardiogram was unremarkable with no ST/T changes. Troponin I was elevated at 4.19 which trended up to 6.57. An urgent cardiac angiogram was done which revealed normal patent coronaries. His transthoracic echocardiogram was also reported to be normal. He continued to have intermittent episodes of chest pain that was partially relieved by morphine. Erythrocyte sedimentation rate and C-reactive protein were elevated. Work up for autoimmune diseases, vasculitis, myocarditis panel were insignificant. Later, magnetic resonance imaging (MRI with gadolinium enhanced contrast (Figure 1 was obtained which showed abnormal epicardial/subepicardial myocardial enhancement within the inferolateral wall and cardiac apex consistent with focal ...

  12. Pathogenetic mechanisms of focal cortical dysplasia.

    Science.gov (United States)

    Marin-Valencia, Isaac; Guerrini, Renzo; Gleeson, Joseph G

    2014-07-01

    Focal cortical dysplasias (FCDs) constitute a prevalent cause of intractable epilepsy in children, and is one of the leading conditions requiring epilepsy surgery. Despite recent advances in the cellular and molecular biology of these conditions, the pathogenetic mechanisms of FCDs remain largely unknown. The purpose if this work is to review the molecular underpinnings of FCDs and to highlight potential therapeutic targets. A systematic review of the literature regarding the histologic, molecular, and electrophysiologic aspects of FCDs was conducted. Disruption of the mammalian target of rapamycin (mTOR) signaling comprises a common pathway underlying the structural and electrical disturbances of some FCDs. Other mechanisms such as viral infections, prematurity, head trauma, and brain tumors are also posited. mTOR inhibitors (i.e., rapamycin) have shown positive results on seizure management in animal models and in a small cohort of patients with FCD. Encouraging progress has been achieved on the molecular and electrophysiologic basis of constitutive cells in the dysplastic tissue. Despite the promising results of mTOR inhibitors, large-scale randomized trials are in need to evaluate their efficacy and side effects, along with additional mechanistic studies for the development of novel, molecular-based diagnostic and therapeutic approaches. Wiley Periodicals, Inc. © 2014 International League Against Epilepsy.

  13. Evaluation of Hemodynamics in Focal Steatosis and Focal Spared Lesion of the Liver Using Contrast-Enhanced Ultrasonography with Sonazoid

    International Nuclear Information System (INIS)

    Shiozawa, K.; Watanabe, M.; Ikehara, T.; Kogame, M.; Shinohara, M.; Shinohara, M.; Ishii, K.; Igarashi, Y.; Sumino, Y.; Shiozawa, K.; Makino, H.

    2014-01-01

    We aim to investigate the hemodynamics in focal steatosis and focal spared lesion of the liver using contrast-enhanced ultrasonography (CEUS) with Sonazoid. The subjects were 47 patients with focal steatosis and focal spared lesion. We evaluated enhancement patterns (hyper enhancement, iso enhancement, and hypo enhancement) in the vascular phase and the presence or absence of a hypoechoic area in the post vascular phase for these lesions using CEUS. Of the 24 patients with focal steatosis, the enhancement pattern was iso enhancement in 19 and hypo enhancement in 5. Hypoechoic areas were noted in the post vascular phase in 3 patients. Of the 23 patients with focal spared lesions, the enhancement pattern was iso enhancement in 18 and hyper enhancement in 5. No hypoechoic areas were noted in the post vascular phase in any patient. The hemodynamics in focal steatosis and focal spared lesions in non diffuse fatty liver can be observed using low-invasive procedures in real-time by CEUS. It was suggested that differences in the dynamics of enhancement in the vascular phase of CEUS were influenced by the fat deposits in the target lesion, the surrounding liver parenchyma, and the third inflow.

  14. Pilot-Assisted Inertial Navigation System Aiding Using Bearings-Only Measurements Taken Over Time

    Science.gov (United States)

    2015-03-26

    their classroom . The students in the GNC track at AFIT, our long tech- nical discussions over coffee or a rip it will be some of my fondest memories...used to constrain the elevation of the ground feature. The E/O system provides a measurement of the ground feature in the inverted image plane dl while...actually inverted . Projecting the inversion of the image frame yields a projection of the scene in front of the aperture the length of the focal

  15. Focal and Ambient Processing of Built Environments: Intellectual and Atmospheric Experiences of Architecture

    Science.gov (United States)

    Rooney, Kevin K.; Condia, Robert J.; Loschky, Lester C.

    2017-01-01

    Neuroscience has well established that human vision divides into the central and peripheral fields of view. Central vision extends from the point of gaze (where we are looking) out to about 5° of visual angle (the width of one’s fist at arm’s length), while peripheral vision is the vast remainder of the visual field. These visual fields project to the parvo and magno ganglion cells, which process distinctly different types of information from the world around us and project that information to the ventral and dorsal visual streams, respectively. Building on the dorsal/ventral stream dichotomy, we can further distinguish between focal processing of central vision, and ambient processing of peripheral vision. Thus, our visual processing of and attention to objects and scenes depends on how and where these stimuli fall on the retina. The built environment is no exception to these dependencies, specifically in terms of how focal object perception and ambient spatial perception create different types of experiences we have with built environments. We argue that these foundational mechanisms of the eye and the visual stream are limiting parameters of architectural experience. We hypothesize that people experience architecture in two basic ways based on these visual limitations; by intellectually assessing architecture consciously through focal object processing and assessing architecture in terms of atmosphere through pre-conscious ambient spatial processing. Furthermore, these separate ways of processing architectural stimuli operate in parallel throughout the visual perceptual system. Thus, a more comprehensive understanding of architecture must take into account that built environments are stimuli that are treated differently by focal and ambient vision, which enable intellectual analysis of architectural experience versus the experience of architectural atmosphere, respectively. We offer this theoretical model to help advance a more precise understanding of the

  16. Método para medida do comprimento da cóclea por meio de ressonância magnética A method for measuring the length of the coclea through magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Fernando Pochini Sobrinho

    2009-04-01

    Full Text Available Sabe-se que a deficiência auditiva afeta boa parte da população. Nos casos em que a surdez é profunda e bilateral, podem ocorrer problemas na aquisição de fala nas crianças, bem como na comunicação e socialização do indivíduo. O implante coclear vem sendo utilizado como opção terapêutica para esses casos. Na atualidade a Ressonância magnética da orelha interna é exame obrigatório na avaliação pré-operatória destes pacientes. No dia-a-dia, nos perguntamos se a ressonância magnética pode fornecer dados não só qualitativos como também quantitativos, com medidas lineares reais na cóclea reconstruída em imagens em três dimensões. OBJETIVO: O objetivo deste estudo é propor uma técnica para obtenção de medidas do comprimento da cóclea em imagens de ressonância magnética obtidos de ossos temporais de cadáveres. MATERIAL E MÉTODO: Foram avaliadas imagens de reconstrução em três dimensões da cóclea de seis cadáveres. Por meio de sobreposição de réguas digitalizadas sobre estas imagens foi possível medir o comprimento coclear. RESULTADO: Estas medidas variaram de 17 a 26,5 milímetros. CONCLUSÃO: Conclui-se que foi possível medir o comprimento da cóclea em imagens em três dimensões de ressonância magnética pelo método proposto.We know that hearing impairment affects a large part of the population. In cases of profound and bilateral hearing loss, children may have problems in speech development, as well as communication and socialization. Cochlear implants have been used as a treatment option in these cases. Today, inner ear MRI is a mandatory test in the preoperative evaluation of these individuals. In our daily routines, we wonder whether MRI can provide not only qualitative, but also quantitative data, with real cochlear linear values built from three dimension images. AIMS: The aim of the present investigation is to propose a method to obtain MRI cochlear length measures from the temporal bones

  17. Focal Atrichia: A Diagnostic Clue in Female Pattern Hair Loss.

    Science.gov (United States)

    Olsen, Elise A; Whiting, David A

    2017-10-07

    Focal atrichia is a common clinical finding in female pattern hair loss whose specificity and histologic findings need further clarification. To determine the frequency of focal atrichia in various types of hair loss and its histologic characteristics in female pattern hair loss. Part 1: Review of 250 consecutive female patients seen with hair loss for the presence of focal atrichia and Part 2: paired biopsies of haired areas vs focal atrichia in 18 subjects with female pattern hair loss RESULTS: Focal atrichia was seen in 46/104 (44%) of women with female pattern hair loss, including 67% of late onset vs 15% of early onset, compared to 3/146 (2%) of those with other hair disorders Biopsy findings of focal atrichia in female pattern hair loss showed primarily a more progressive miniaturization process than that of haired areas of the scalp. Some women with female pattern hair loss may have had concomitant chronic telogen effluvium CONCLUSIONS: When present, focal atrichia is a clinical clue to the diagnosis of female pattern hair loss, particularly late onset subtype. Copyright © 2017. Published by Elsevier Inc.

  18. The dispersion-focalization theory of sound systems

    Science.gov (United States)

    Schwartz, Jean-Luc; Abry, Christian; Boë, Louis-Jean; Vallée, Nathalie; Ménard, Lucie

    2005-04-01

    The Dispersion-Focalization Theory states that sound systems in human languages are shaped by two major perceptual constraints: dispersion driving auditory contrast towards maximal or sufficient values [B. Lindblom, J. Phonetics 18, 135-152 (1990)] and focalization driving auditory spectra towards patterns with close neighboring formants. Dispersion is computed from the sum of the inverse squared inter-spectra distances in the (F1, F2, F3, F4) space, using a non-linear process based on the 3.5 Bark critical distance to estimate F2'. Focalization is based on the idea that close neighboring formants produce vowel spectra with marked peaks, easier to process and memorize in the auditory system. Evidence for increased stability of focal vowels in short-term memory was provided in a discrimination experiment on adult French subjects [J. L. Schwartz and P. Escudier, Speech Comm. 8, 235-259 (1989)]. A reanalysis of infant discrimination data shows that focalization could well be the responsible for recurrent discrimination asymmetries [J. L. Schwartz et al., Speech Comm. (in press)]. Recent data about children vowel production indicate that focalization seems to be part of the perceptual templates driving speech development. The Dispersion-Focalization Theory produces valid predictions for both vowel and consonant systems, in relation with available databases of human languages inventories.

  19. The semiology of febrile seizures: Focal features are frequent.

    Science.gov (United States)

    Takasu, Michihiko; Kubota, Tetsuo; Tsuji, Takeshi; Kurahashi, Hirokazu; Numoto, Shingo; Watanabe, Kazuyoshi; Okumura, Akihisa

    2017-08-01

    To clarify the semiology of febrile seizures (FS) and to determine the frequency of FS with symptoms suggestive of focal onset. FS symptoms in children were reported within 24h of seizure onset by the parents using a structured questionnaire consisting principally of closed-ended questions. We focused on events at seizure commencement, including changes in behavior and facial expression, and ocular and oral symptoms. We also investigated the autonomic and motor symptoms developing during seizures. The presence or absence of focal and limbic features was determined for each patient. The associations of certain focal and limbic features with patient characteristics were assessed. Information was obtained on FS in 106 children. Various events were recorded at seizure commencement. Behavioral changes were observed in 35 children, changes in facial expression in 53, ocular symptoms in 78, and oral symptoms in 90. In terms of events during seizures, autonomic symptoms were recognized in 78, and convulsive motor symptoms were recognized in 68 children. Focal features were evident in 81 children; 38 children had two or more such features. Limbic features were observed in 44 children, 9 of whom had two or more such features. There was no significant relationship between any patient characteristic and the numbers of focal or limbic features. The semiology of FS varied widely among children, and symptoms suggestive of focal onset were frequent. FS of focal onset may be more common than is generally thought. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Syncope causes transient focal neurological symptoms.

    Science.gov (United States)

    Ryan, D J; Harbison, J A; Meaney, J F; Rice, C P; King-Kallimanis, B; Kenny, R A

    2015-09-01

    The prevalence of focal neurology (FN) as a consequence of syncope is unknown. The aim of the study was to determine its prevalence, risk factors and short-term consequences. A consecutive sample of syncope-unit attendees during a 9-month period had detailed diagnostic syncope evaluation as per European Cardiac Society guidelines coupled with assessment for FN present during syncope/pre-syncope by screening questionnaire, follow-up interview and neuroimaging (1.5T magnetic resonance imaging [MRI]). All participants were followed up for 24 months. Risk factors for FN were identified by comparing FN cases with syncope controls without FN (3:1 ratio). Five-hundred and forty consecutively attended for investigation of syncope (n = 401) and pre-syncope (n = 139). Thirty-one (5.7%) had FN events during hypotensive symptoms, mean age 49 years (19-85). The majority of FN cases had vasovagal syncope (VVS); 22 (71%), whereas eight had OH (25.8%) and one (3.2%) had cardiac arrhythmia. Median duration of FN was 15 min (IQR: 34.5). MRI in 28 (90%) was normal and in 3, old cerebral infarction was evident. Risk factors for FN/syncope were frequent syncope (P = 0·008), childhood syncope (P syncope/pre-syncope have co-extant FN, which during 24-month follow-up, does not progress to a persistent deficit (>24 h). Awareness of co-occurrence of FN and syncope is important as stroke misdiagnosis results in aggressive anti-hypertensive management and future events may ensue. © The Author 2015. Published by Oxford University Press on behalf of the Association of Physicians. All rights reserved. For Permissions, please email: journals.permissions@oup.com.