WorldWideScience

Sample records for fluoro-misonidazole positron emission

  1. Quantitative analysis of fluorodeoxyglucose-, fluoro-misonidazole- and fluoro-thymidine-PET images on five patients irradiated for a non-small-cell bronchial cancer; Analyse quantitative d'images de TEP au fluorodesoxyglucose, au fluoromisonidazole et a la fluorothymidine chez cinq patients irradies pour un cancer bronchique non a petites cellules

    Energy Technology Data Exchange (ETDEWEB)

    Thureau, S.; Dubray, B. [Departement de radiotherapie et physique medicale, centre Henri-Becquerel, Rouen (France); Litis EA 4108, QuantiF, universite de Rouen, Rouen (France); Modzelewski, R.; Lelandais, B.; Edet Sanson, A.; Gardin, I.; Vera, P. [Litis EA 4108, QuantiF, universite de Rouen, Rouen (France); Departement de medecine nucleaire, centre Henri-Becquerel, Rouen (France)

    2011-10-15

    As fluorodeoxyglucose-PET (positron emission tomography) is used for the planning of non-small-cell bronchial carcinoma radiotherapy in order to help to define the gross tumour volume (GTV), and as new tracers have been developed to define a biological target volume, the authors report the comparison of several thresholding methods by using fluorodeoxyglucose-, fluoro-misonidazole- and fluoro-thymidine-PET images. They notice important differences between the delineated volumes. Short communication

  2. The role of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in resectable pancreatic cancer.

    Science.gov (United States)

    Crippa, Stefano; Salgarello, Matteo; Laiti, Silvia; Partelli, Stefano; Castelli, Paola; Spinelli, Antonello E; Tamburrino, Domenico; Zamboni, Giuseppe; Falconi, Massimo

    2014-08-01

    The role of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in pancreatic ductal adenocarcinoma is debated. We retrospectively assessed the value of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in addition to conventional imaging as a staging modality in pancreatic cancer. (18)Fluoro-deoxyglucose positron emission tomography/computed tomography was performed in 72 patients with resectable pancreatic carcinoma after multi-detector computed tomography positron emission tomography was considered positive for a maximum standardized uptake value >3. Overall, 21% of patients had a maximum standardized uptake value ≤ 3, and 60% of those had undergone neoadjuvant treatment (P=0.0001). Furthermore, 11% of patients were spared unwarranted surgery since positron emission tomography/computed tomography detected metastatic disease. All liver metastases were subsequently identified with contrast-enhanced ultrasound. Sensitivity and specificity of positron emission tomography/computed tomography for distant metastases were 78% and 100%. The median CA19.9 concentration was 48.8 U/mL for the entire cohort and 292 U/mL for metastatic patients (P=0.112). The widespread application of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in patients with resectable pancreatic carcinoma seems not justified. It should be considered in selected patients at higher risk of metastatic disease (i.e. CA19.9>200 U/mL) after undergoing other imaging tests. Neoadjuvant treatment is significantly associated with low metabolic activity, limiting the value of positron emission tomography in this setting. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  3. 2-¹⁸fluoro-deoxy-D-glucose positron emission tomography (FDG-PET) for postchemotherapy seminoma residual lesions

    DEFF Research Database (Denmark)

    Bachner, M; Loriot, Y; Gross-Goupil, M

    2012-01-01

    2-¹⁸fluoro-deoxy-D-glucose positron emission tomography (FDG-PET) has been recommended in international guidelines in the evaluation of postchemotherapy seminoma residuals. Our trial was designed to validate these recommendations in a larger group of patients.......2-¹⁸fluoro-deoxy-D-glucose positron emission tomography (FDG-PET) has been recommended in international guidelines in the evaluation of postchemotherapy seminoma residuals. Our trial was designed to validate these recommendations in a larger group of patients....

  4. Incidental head and neck findings on 18F-fluoro-deoxy-glucose positron emission tomography computed tomography.

    Science.gov (United States)

    Williams, S P; Kinshuck, A J; Williams, C; Dwivedi, R; Wieshmann, H; Jones, T M

    2015-09-01

    The overlapping risk factors for lung and head and neck cancer present a definite risk of synchronous malignant pathology. This is the first study to specifically review incidental positron emission tomography computed tomography findings in the head and neck region in lung carcinoma patients. A retrospective review was performed of all lung cancer patients who underwent positron emission tomography computed tomography imaging over a five-year period (January 2008 - December 2012), identified from the Liverpool thoracic multidisciplinary team database. Six hundred and nine patients underwent positron emission tomography computed tomography imaging over this period. In 76 (12.5 per cent) scans, incidental regions of avid 18F-fluoro-deoxy-glucose uptake were reported in the head and neck region. In the 28 patients who were fully investigated, there were 4 incidental findings of malignancy. In lung cancer patients undergoing investigative positron emission tomography computed tomography scanning, a significant number will also present with areas of clinically significant 18F-fluoro-deoxy-glucose uptake in the head and neck region. Of these, at least 5 per cent may have an undiagnosed malignancy.

  5. The role of 18F-fluoro-2-deoxyglucose positron emission tomography/computed tomography in the management of patients with carcinoma of unknown primary.

    Science.gov (United States)

    Deonarine, P; Han, S; Poon, F W; de Wet, C

    2013-08-01

    Carcinoma of unknown primary is one of the ten most frequent cancers worldwide. Its median survival time is less than 10 months. Detecting primary tumour locations and/or occult metastatic lesions may inform definitive treatment and improve patients' prognosis. We aimed to determine: (1) the sensitivity, specificity and accuracy of (18)F-fluoro-2-deoxyglucose positron emission tomography/computed tomography; (2) its detection rate of primary tumour locations and occult metastases and (3) factors associated with improved survival times. We retrospectively reviewed all cases in the West of Scotland for the period 1 December 2007 to 31 May 2011 that met all our selection criteria: (1) diagnosis of carcinoma of unknown primary; (2) a thorough but negative 'work-up' and (3) (18)F-fluoro-2-deoxyglucose positron emission tomography/computed tomography report. Statistical methods included frequencies, Kaplan-Meier graphs and log-rank tests to compare survival times. (18)F-fluoro-2-deoxyglucose positron emission tomography/computed tomography detected primary tumour sites in 19/51 (37.3%) and occult metastases in 28/51 (54.9%) of eligible patients. Its sensitivity, specificity and accuracy were 79.2%, 70.4% and 74.5%, respectively; 20/51 (39.2%) patients died during the study period with a median survival of 8.4 months (range 21.4, SD ± 6.2). The number of metastatic locations was strongly associated with survival (p = 0.002), but detection of a primary tumour site (p = 0.174) or histopathology (p = 0.301) was not. (18)F-fluoro-2-deoxyglucose positron emission tomography/computed tomography detected occult metastatic sites in the majority and a primary cancer location in a substantial minority of patients. Our results were comparable with international literature and may indicate that (18)F-fluoro-2-deoxyglucose positron emission tomography/computed tomography have an early role to improve the accuracy of cancer staging and to optimise carcinoma of unknown

  6. Increased fluoro-deoxy-D-glucose uptake on positron emission tomography-computed tomography postbronchoalveolar lavage: a potential cause of radiologic misinterpretation.

    LENUS (Irish Health Repository)

    Leong, Sum

    2011-08-01

    Cytologic analysis of bronchoalveolar lavage (BAL) fluid is used for lung cancer diagnosis. We describe a patient with a history of rectal carcinoma who presented with a new lung mass. BAL was performed, with positron emission tomography-computed tomography the following day. There was mildly increased fluoro-deoxy-D-glucose uptake in areas of the lung parenchyma with new ground-glass opacification. This created ambiguity in staging, clarified 2 weeks later by a computed tomography showing complete resolution of the ground-glass opacity. Clinicians should be aware that BAL may cause increased pulmonary fluoro-deoxy-D-glucose uptake, making accurate radiologic interpretation problematic. We suggest that to optimize positron emission tomography-computed tomography, studies should not be performed within 24 hours of BAL.

  7. Preclinical evaluation of a positron emitting progestin ([18F]fluoro-16 alpha-methyl-19-norprogesterone) for imaging progesterone receptor positive tumours with positron emission tomography

    NARCIS (Netherlands)

    Verhagen, Aalt; Luurtsema, Gert; PESSER, JW; DEGROOT, TJ; OOSTERHUIS, JW; Vaalburg, Willem; Wouda, S.

    Three 21-fluoro-progestins were investigated as potential imaging agents for the in vivo assessment of human progesterone receptor positive neoplasms with positron emission tomography. In competitive binding assays these compounds demonstrated high specificity, competing only for progesterone

  8. Transformation of myelodysplastic syndrome to acute myeloid leukemia: a case with whole-body 2- (18F) fluoro-2-deoxy-D-glucose positron emission tomography

    International Nuclear Information System (INIS)

    Liu, Fang; Cao, Qinghua

    2011-01-01

    The case reported here was that of an old woman characterized by pancytopenia, chromosome clonal abnormality, fluctuation of the percent of blast cells at 20%, and negative evidence of malignancy in whole-body 2-( 18 F) fluoro-2-deoxy-D-glucose positron emission tomography ( 18 F-FDG PET). After about 10 months, the blast cells accounted for about 25%, the morphology of which was similar to that of previous ones, and 18 F-FDG PET demonstrated diffusing increased uptake in the right upper leg and lymph nodes and patchy high uptake of bone marrow. 2-( 18 F)-fluoro-2-deoxyglucose can reflect extramedullary infiltration and bone marrow cellularity of the whole body, compared with invasive, regional biopsies and aspirations. The value of 2-( 18 F)-fluoro-2-deoxyglucose or 3'-deoxy-3'-( 18 F)-fluorothymidine positron emission tomography as an indicator in predicting the transformation of myelodysplastic syndrome to acute myeloid leukemia needs to be explored in the future. (author)

  9. Comparison of five segmentation tools for 18F-fluoro-deoxy-glucose-positron emission tomography-based target volume definition in head and neck cancer.

    NARCIS (Netherlands)

    Schinagl, D.A.X.; Vogel, W.V.; Hoffmann, A.L.; Dalen, J.A. van; Oyen, W.J.G.; Kaanders, J.H.A.M.

    2007-01-01

    PURPOSE: Target-volume delineation for radiation treatment to the head and neck area traditionally is based on physical examination, computed tomography (CT), and magnetic resonance imaging. Additional molecular imaging with (18)F-fluoro-deoxy-glucose (FDG)-positron emission tomography (PET) may

  10. Basic principles of 18F-fluoro-deoxyglucose positron emission tomography

    International Nuclear Information System (INIS)

    Standke, R.

    2002-01-01

    Positron emission tomography uses photons to receive regional information about dynamic, physiologic, and biochemical processes in the living body. A positron decay is measured indirectly by the simultaneous registration of both gamma rays created by the annihilation. The event is counted, if two directly opposite located detectors register gamma rays in coincidence. Unfortunately the detectors of a positron emission tomography system do not register only true coincident events. There are also scattered and random coincidences. Different types of positron tomographs are presented and scintillation crystals, which are in use for positron emission tomography are discussed. The 2D- and 3D-acquisition methods are described as well as preprocessing methods, such as correction for attenuation, scatter and dead time. For quantification the relative parameter standard uptake value (SUV) is explained. Finally hybrid systems, such as combined positron emission tomography/computed tomography scanners and the use of computed tomography data for attenuation correction are introduced. (author)

  11. 2-18F-fluoro-2-deoxyglucose positron emission tomography in delirium.

    Science.gov (United States)

    Haggstrom, Lucy R; Nelson, Julia A; Wegner, Eva A; Caplan, Gideon A

    2017-11-01

    Delirium is a common, serious, yet poorly understood syndrome. Growing evidence suggests cerebral metabolism is fundamentally disturbed; however, it has not been investigated using 2- 18 F-fluoro-2-deoxyglucose (FDG) positron emission tomography (PET) in delirium. This prospective study thus explored FDG PET patterns of cerebral glucose metabolism in older inpatients with delirium. A particular emphasis was on the posterior cingulate cortex (PCC), a key region for attention, which is a central feature of delirium. Delirium scans were compared with post-delirium scans using visual analysis and semi-quantitative analysis with NeuroQ; 13 participants (8 female, median 84 y) were scanned during delirium, and 6 scanned again after resolution. On visual analysis, cortical hypometabolism was evident in all participants during delirium (13/13), and improved with delirium resolution (6/6). Using NeuroQ, glucose metabolism was higher post-delirium in the whole brain and bilateral PCC compared to during delirium ( p delirium duration. This research found widespread, reversible cortical hypometabolism during delirium and PCC hypometabolism was associated with inattention during delirium.

  12. Lynch Syndrome Associated Colon Adenocarcinoma Resembling Lymphoma on Fluoro-Deoxyglucose-Positron Emission Tomography/Computed Tomography

    International Nuclear Information System (INIS)

    Aparici, Carina Mari; Win, Aung Zaw

    2015-01-01

    The patient was a 46-year-old Asian male diagnosed with lynch syndrome associated colon adenocarcinoma in the right ascending colon. A presurgical staging 18-fluoro-deoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) found increased metabolic activity in the cervical, axillary, mediastinal, supraclavicular, para-aortic and mesenteric lymph nodes. This pattern of metastasis was very unusual for lynch syndrome associated colon adenocarcinoma and the involvement of those lymph nodes resembles the pattern of spread of lymphoma. He underwent right hemicolectomy and he was subsequently treated with 12 cycles of folinic acid (leucovorin), fluorouracil (5-FU), irinotecan. A restaging FDG-PET/CT at the end of the chemotherapy showed interval decrease in size and metabolic activity in the affected lymph nodes. FDG-PET/CT is a useful imaging modality in following-up the treatment response in colon adenocarcinoma

  13. Hemiballismus: Study of a case using positron emission tomography with 18fluoro-2-deoxyglucose

    International Nuclear Information System (INIS)

    Dubinsky, R.M.; Greenberg, M.; Di Chiro, G.; Baker, M.; Hallett, M.

    1989-01-01

    A 64-year-old man had right-sided persistent hemiballismus. Cerebral computed tomography (CT) and 0.5-T magnetic resonance imaging (MRI) showed no abnormalities, but 1.5-T MRI showed decreased signal intensity of the putamina, greater on the left than on the right. The subthalamic area was normal on CT and MRI. Positron emission tomography with 18fluoro2-deoxyglucose showed marked hypometabolism of the left putamen (60% of the right) and hypermetabolism of the left parietal lobe (138% of the right). The decreased metabolism of the left putamen may indicate a reduction in neuronal firing. The pathophysiology of the hemiballismus in this case may be loss of tonic inhibition of the lateral globus pallidus from the putamen, leading in turn to greater inhibition of the subthalamic nucleus, less excitation of the medial globus pallidus, and less inhibition of the thalamus and motor cortex, and thus allowing expression of the ballistic movements

  14. Anti-leucine rich glioma inactivated 1 protein and anti-N-methyl-D-aspartate receptor encephalitis show distinct patterns of brain glucose metabolism in 18F-fluoro-2-deoxy-d-glucose positron emission tomography.

    Science.gov (United States)

    Wegner, Florian; Wilke, Florian; Raab, Peter; Tayeb, Said Ben; Boeck, Anna-Lena; Haense, Cathleen; Trebst, Corinna; Voss, Elke; Schrader, Christoph; Logemann, Frank; Ahrens, Jörg; Leffler, Andreas; Rodriguez-Raecke, Rea; Dengler, Reinhard; Geworski, Lilli; Bengel, Frank M; Berding, Georg; Stangel, Martin; Nabavi, Elham

    2014-06-20

    Pathogenic autoantibodies targeting the recently identified leucine rich glioma inactivated 1 protein and the subunit 1 of the N-methyl-D-aspartate receptor induce autoimmune encephalitis. A comparison of brain metabolic patterns in 18F-fluoro-2-deoxy-d-glucose positron emission tomography of anti-leucine rich glioma inactivated 1 protein and anti-N-methyl-D-aspartate receptor encephalitis patients has not been performed yet and shall be helpful in differentiating these two most common forms of autoimmune encephalitis. The brain 18F-fluoro-2-deoxy-d-glucose uptake from whole-body positron emission tomography of six anti-N-methyl-D-aspartate receptor encephalitis patients and four patients with anti-leucine rich glioma inactivated 1 protein encephalitis admitted to Hannover Medical School between 2008 and 2012 was retrospectively analyzed and compared to matched controls. Group analysis of anti-N-methyl-D-aspartate encephalitis patients demonstrated regionally limited hypermetabolism in frontotemporal areas contrasting an extensive hypometabolism in parietal lobes, whereas the anti-leucine rich glioma inactivated 1 protein syndrome was characterized by hypermetabolism in cerebellar, basal ganglia, occipital and precentral areas and minor frontomesial hypometabolism. This retrospective 18F-fluoro-2-deoxy-d-glucose positron emission tomography study provides novel evidence for distinct brain metabolic patterns in patients with anti-leucine rich glioma inactivated 1 protein and anti-N-methyl-D-aspartate receptor encephalitis.

  15. 6-[F-18]Fluoro-L-Dihydroxyphenylalanine Positron Emission Tomography Is Superior to Conventional Imaging with I-123-Metaiodobenzylguanidine Scintigraphy, Computer Tomography, and Magnetic Resonance Imaging in Localizing Tumors Causing Catecholamine Excess

    NARCIS (Netherlands)

    Fiebrich, Helle-Brit; Brouwers, Adrienne H.; Kerstens, Michiel N.; Pijl, Milan E. J.; Kema, Ido P.; de Jong, Johan R.; Jager, Pieter L.; Elsinga, Philip H.; Dierckx, Rudi A. J. O.; van der Wal, Jacqueline E.; Sluiter, Wim J.; de Vries, Elisabeth G. E.; Links, Thera P.

    2009-01-01

    Context: Catecholamine excess is rare, but symptoms may be life threatening. Objective: The objective of the study was to investigate the sensitivity of 6-[F-18]fluoro-L-dihydroxyphenylalanine positron emission tomography (F-18-DOPAPET), compared with I-123-metaiodobenzylguanidine (I-123-MIBG)

  16. Positron emission tomography for the assessment of myocardial viability

    International Nuclear Information System (INIS)

    Schelbert, H.R.

    1991-01-01

    The detection of viable myocardium or ischemically injured myocardium with a reversible impairment of contractile function remains clinically important but challenging. Detection of reversible dysfunction and distinction from irreversible tissue injury by positron emission tomography is based on identification of preserved or even enhanced glucose metabolism with F-18 2-fluoro 2-deoxyglucose. Regional patterns of myocardial glucose utilization and blood flow, defined as perfusion-metabolism mismatches or matches, on positron emission tomography in patients with chronic or even acute ischemic heart disease are highly accurate in predicting the functional outcome after interventional revascularization. Compared with thallium-201 redistribution scintigraphy, positron emission tomography appears to be diagnostically more accurate, especially in patients with severely impaired left ventricular function. While larger clinical trials are needed for further confirmation, positron emission tomography has already proved clinically useful for stratifying patients with poor left ventricular function to the most appropriate therapeutic approach

  17. Primary pulmonary lymphoma-role of fluoro-deoxy-glucose positron emission tomography-computed tomography in the initial staging and evaluating response to treatment - case reports and review of literature

    International Nuclear Information System (INIS)

    Agarwal, Krishan Kant; Dhanapathi, Halanaik; Nazar, Aftab Hasan; Kumar, Rakesh

    2016-01-01

    Primary pulmonary lymphoma (PPL) is an uncommon entity of non-Hodgkin lymphoma, which accounts for <1% of all cases of lymphoma. We present two rare cases of PPL of diffuse large B-cell lymphoma, which underwent 18 fluorine fluoro-deoxy-glucose positron emission tomography-computed tomography for initial staging and response evaluation after chemotherapy

  18. Prediction of Central Nervous System Relapse of Diffuse Large B-Cell Lymphoma Using Pretherapeutic [18F]2-Fluoro-2-Deoxyglucose (FDG) Positron Emission Tomography/Computed Tomography.

    Science.gov (United States)

    Song, Yoo Sung; Lee, Won Woo; Lee, Jong Seok; Kim, Sang Eun

    2015-11-01

    Central nervous system (CNS) relapse of diffuse large B-cell lymphoma (DLBCL) is a rare complication, but has a poor prognosis with unknown pathophysiology. Recent trials of CNS prophylaxis have shown to be ineffective, despite patient's selection using several known clinical risk factors. In this study, the authors evaluated the value of pretreatment [F]2-Fluoro-2-deoxyglucose positron emission tomography in predicting CNS relapse in DLBCL patients.The authors analyzed 180 pathologically confirmed DLBCL patients, retrospectively. Patients underwent [F]2-Fluoro-2-deoxyglucose positron emission tomography/computed tomography before first line rituximab to cyclophosphamide, doxorubicin, vincristine, and prednisone therapy. Clinical characteristics were evaluated and total lesion glycolysis (TLG) with a threshold margin of 50% was calculated.Among age, sex, Ann Arbor stage, International Prognostic Index, revised International Prognostic Index, high serum lactate dehydrogenase level, presence of B symptoms, bulky disease (≥10 cm), extranodal lesion involvement, bone marrow involvement, high metabolic tumor volume ( >450 mL), and high TLG50 (>2000), the high TLG50 was the only significant prognostic factor for predicting CNS relapse in a multivariate analysis (P = 0.04). Kaplan-Meir survival analysis between high TLG50 (>2000) and low TLG50 (≤2000) groups revealed significantly different mean progression free survival (PFS) of 1317.2 ± 134.3 days and 1968.6 ± 18.3 days, respectively (P positron emission tomography/computed tomography is the most significant predictor of CNS relapse in un-treated DLBCL patients.

  19. Difference in prognostic significance of maximum standardized uptake value on [18F]-fluoro-2-deoxyglucose positron emission tomography between adenocarcinoma and squamous cell carcinoma of the lung

    International Nuclear Information System (INIS)

    Tsutani, Yasuhiro; Miyata, Yoshihiro; Misumi, Keizo; Ikeda, Takuhiro; Mimura, Takeshi; Hihara, Jun; Okada, Morihito

    2011-01-01

    This study evaluates the prognostic significance of [18F]-fluoro-2-deoxyglucose positron emission tomography/computed tomography findings according to histological subtypes in patients with completely resected non-small cell lung cancer. We examined 176 consecutive patients who had undergone preoperative [18F]-fluoro-2-deoxyglucose-positron emission tomography/computed tomography imaging and curative surgical resection for adenocarcinoma (n=132) or squamous cell carcinoma (n=44). Maximum standardized uptake values for the primary lesions in all patients were calculated as the [18F]-fluoro-2-deoxyglucose uptake and the surgical results were analyzed. The median values of maximum standardized uptake value for the primary tumors were 2.60 in patients with adenocarcinoma and 6.95 in patients with squamous cell carcinoma (P 6.95 (P=0.83) among patients with squamous cell carcinoma, 2-year disease-free survival rates were 93.9% for maximum standardized uptake value ≤3.7 and 52.4% for maximum standardized uptake value >3.7 (P<0.0001) among those with adenocarcinoma, and notably, 100 and 57.2%, respectively, in patients with Stage I adenocarcinoma (P<0.0001). On the basis of the multivariate Cox analyses of patients with adenocarcinoma, maximum standardized uptake value (P=0.008) was a significantly independent factor for disease-free survival as well as nodal metastasis (P=0.001). Maximum standardized uptake value of the primary tumor was a powerful prognostic determinant for patients with adenocarcinoma, but not with squamous cell carcinoma of the lung. (author)

  20. Positron emission tomography for staging of oesophageal and gastroesophageal malignancy

    NARCIS (Netherlands)

    Kole, AC; Plukker, JT; Nieweg, OE; Vaalburg, W

    Positron emission tomography (PET) with [F-18]-fluoro-2-deoxy-D-glucose (FDG) was prospectively investigated as a means of detecting metastatic disease in patients with oesophageal tumours and compared with computerized tomography (CT), with the surgical findings as a gold standard. Twenty-six

  1. Tumour imaging by Positron Emission Tomography using fluorinase generated 5-[18F]fluoro-5-deoxyribose as a novel tracer

    International Nuclear Information System (INIS)

    Dall'Angelo, Sergio; Bandaranayaka, Nouchali; Windhorst, Albert D.; Vugts, Danielle J.; Born, Dion van der; Onega, Mayca; Schweiger, Lutz F.; Zanda, Matteo; O'Hagan, David

    2013-01-01

    Introduction: 5-[ 18 F]Fluoro-5-deoxyribose ([ 18 F]FDR) 3 was prepared as a novel monosaccharide radiotracer in a two-step synthesis using the fluorinase, a C-F bond forming enzyme, and a nucleoside hydrolase. The resulting [ 18 F]FDR 3 was then explored as a radiotracer for imaging tumours (A431 human epithelial carcinoma) by positron emission tomography in a mice model. Methods: 5-[ 18 F]Fluoro-5-deoxyribose ([ 18 F]FDR) 3, was prepared by incubating S-adenosyl-L-methionine (SAM) and [ 18 F]fluoride with the fluorinase enzyme, and then incubating the product of this reaction, [ 18 F]-5'-fluoro-5'-deoxadenosine ([ 18 F]FDA) 2, with an adenosine hydrolase to generate [ 18 F]FDR 3. The enzymes were freeze-dried and were used on demand by dissolution in buffer solution. The resulting [ 18 F]FDR 3 was then administered to four mice that had tumours induced from the A431 human epithelial carcinoma cell line. Results: The tumour (A431 human epithelial carcinoma) bearing mice were successfully imaged with [ 18 F]FDR 3. The radiotracer displayed good tumour imaging resolution. A direct comparison of the uptake and efflux of [ 18 F]FDR 3 with 2-[ 18 F]fluoro-2-deoxyglucose ([ 18 F]FDG) was made, revealing comparative tumour uptake and imaging potential over the first 10–20 min. The study revealed however that [ 18 F]FDR 3 does not accumulate in the tumour as efficiently as [ 18 F]FDG over longer time periods. Conclusions: [ 18 F]FDR 3 can be rapidly synthesised in a two enzyme protocol and used to image tumours in small animal models

  2. Striatal kinetics of [11C]-(+)-nomifensine and 6-[18F]fluoro-L-dopa in Parkinson's disease measured with positron emission tomography

    International Nuclear Information System (INIS)

    Tedroff, J.; Aquilonius, S.-M.; Laihinen, A.; Rinne, U.; Hartvig, P.; Anderson, J.; Lundqvist, H.; Haaparanta, M.; Solin, O.; Antoni, G.; Gee, A.D.; Ulin, J.; Laangstroem, B.

    1990-01-01

    The kinetics in brain of the dopamine reuptake blocking agent [ 11 C]-(+)-nomifensine and the L-dopa analogue 6-[ 18 F]fluoro-L-dopa were compared in 3 patients with idopathic Parkinson's disease and agematched healthy volunteers using positron emission tomography. Regional uptake was analyzed and quantified according to a 3-compartment model. Retention of both tracers in striatal regions of the parkinsonian patients were reduced compared with the healthy volunteers mainly in the putamen, while the caudate nuclleus was only mildly affected. The reductions were considerably less than the decrease previously reported postmortem for striatal dopamine content in the basal ganglia of patients with Parkinson's disease. A fairly constant ratio between 6-[ 18 F]fluoro-L-dopa utilization and [ 11 C]-(+)-nomifensine binding in the caudate nucleus and the putamen were found in both groups unrelated to the size of the estimated parameters. This indicates that a limiting factor for the utilization of exogenous levodopa in Parkinsons's disease may be a reduced transport capacity for the amino acid into the dopaminergic terminals. (author)

  3. Electrocardiographic gating in positron emission computed tomography

    International Nuclear Information System (INIS)

    Hoffman, E.J.; Phelps, M.E.; Wisenberg, G.; Schelbert, H.R.; Kuhl, D.E.

    1979-01-01

    Electrocardiographic (ECG) synchronized multiple gated data acquisition was employed with positron emission computed tomography (ECT) to obtain images of myocardial blood pool and myocardium. The feasibility and requirements of multiple gated data acquisition in positron ECT were investigated for 13NH3, ( 18 F)-2-fluoro-2-D-deoxyglucose, and ( 11 C)-carboxyhemoglobin. Examples are shown in which image detail is enhanced and image interpretation is facilitated when ECG gating is employed in the data collection. Analysis of count rate data from a series of volunteers indicates that multiple, statistically adequate images can be obtained under a multiple gated data collection format without an increase in administered dose

  4. 2-deoxy-2-(18F)fluoro-D-glucose positron emission tomography/computed tomography imaging in paediatric oncology

    Institute of Scientific and Technical Information of China (English)

    John; Freebody; Eva; A; Wegner; Monica; A; Rossleigh

    2014-01-01

    Positron emission tomography(PET) is a minimally in-vasive technique which has been well validated for the diagnosis, staging, monitoring of response to therapy, and disease surveillance of adult oncology patients. Tra-ditionally the value of PET and PET/computed tomogra-phy(CT) hybrid imaging has been less clearly defined for paediatric oncology. However recent evidence has emerged regarding the diagnostic utility of these mo-dalities, and they are becoming increasingly important tools in the evaluation and monitoring of children with known or suspected malignant disease. Important indi-cations for 2-deoxy-2-(18F)fluoro-D-glucose(FDG) PET in paediatric oncology include lymphoma, brain tumours, sarcoma, neuroblastoma, Langerhans cell histiocytosis, urogenital tumours and neurofibromatosis type Ⅰ. This article aims to review current evidence for the use of FDG PET and PET/CT in these indications. Attention will also be given to technical and logistical issues, the description of common imaging pitfalls, and dosimetric concerns as they relate to paediatric oncology.

  5. Development of radiotracers for imaging NR2B subtype NMDA receptors with positron emission tomography

    International Nuclear Information System (INIS)

    Labas, R.

    2007-01-01

    The aim of this thesis was to develop new radioactive tracers for imaging NR2B subtype NMDA receptors with positron emission tomography. Several compounds including 4-(4-fluoro-benzyl)piperidine and presenting interesting in vivo biological properties were the object of a labelling with a positrons emitter atom ( 11 C or 18 F)

  6. Neuromyelitis optica spectrum disorder: 2-deoxy-2-[18F]fluoro-D-glucose positron emission tomography findings--case report.

    Science.gov (United States)

    Oyama, Hirofumi; Miwa, Shigeru; Noda, Tomoyuki; Sobajima, Atsuhiro; Kito, Akira; Maki, Hideki; Hattori, Kenichi; Wada, Kentaro

    2012-01-01

    A 51-year-old female with a history of rheumatoid arthritis rapidly developed anterior neck pain and paresis in the left upper and lower extremities and right lower extremity, sensory disturbance in the left upper and lower extremities, and bladder and rectal disorder. Adduction of the left eye and abduction of the right eye were also disturbed. Spinal magnetic resonance imaging demonstrated severe edema in the C1-T5 levels, which then deteriorated rapidly over 3 days, and lesions enhanced with gadolinium in the C1-C3 and C5-T3 levels. 2-Deoxy-2-[18F]fluoro-D-glucose positron emission tomography study demonstrated the inflammatory sites as segmental enhanced accumulation in the C1-C3, C5-C6, and T1 levels. The serum anti-aquaporin 4 antibody level was positive and she was diagnosed with neuromyelitis optica spectrum disorder. Marked improvement in the neurological conditions, concomitant with reduced spinal cord edema, was obtained by steroid pulse therapy.

  7. Dynamic 2-[18F]fluoro-2-deoxy-D-glucose positron emission tomography of liver tumours without blood sampling

    DEFF Research Database (Denmark)

    Keiding, S; Munk, O L; Schiøtt, K M

    2000-01-01

    Positron emission tomography (PET) using 2-[18F]fluoro-2-deoxy-D-glucose (FDG) is a useful diagnostic tool for the detection of tumours. Using dynamic FDG PET, net metabolic clearance of FDG, K, can be calculated by Gjedde-Patlak analysis of the time course of the radioactivity concentrations...... in tissue and arterial blood. We examined whether time-activity curves (TACs) based on arterial blood sampling could be replaced by TACs obtained from the descending aorta in dynamic PET scans of patients with liver tumours. The study was performed in two parts, using data from dynamic liver scans......, and 2.1-8.4:1 (mean, 4.6:1) based on blood sample TACs (P>0.3). We conclude that arterial blood sampling can be replaced by the present AORTA-VOI in the calculation of the net metabolic clearance of FDG in dynamic PET studies of liver tumours in human subjects. Udgivelsesdato: 2000-Apr...

  8. Striatal kinetics of ( sup 11 C)-(+)-nomifensine and 6-( sup 18 F)fluoro-L-dopa in Parkinson's disease measured with positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Tedroff, J; Aquilonius, S -M [Department of Neurology, University Hospital (Sweden); Laihinen, A; Rinne, U [Department of Neurology, University of Turku (Finland); Hartvig, P [Department of Hospital Pharmacy, University Hospital (Sweden); Anderson, J [Department of Radiation Sciences, University Hospital (Sweden); Lundqvist, H [Svenberg Laboratory, Uppsala University (Sweden); Haaparanta, M; Solin, O [Medical Cyclotron Laboratory, University of Turku (Finland); Antoni, G; Gee, A D; Ulin, J; Laangstroem, B [Department of Organic Chemistry, University Hospital (Sweden)

    1990-01-01

    The kinetics in brain of the dopamine reuptake blocking agent ({sup 11}C)-(+)-nomifensine and the L-dopa analogue 6-({sup 18}F)fluoro-L-dopa were compared in 3 patients with idopathic Parkinson's disease and agematched healthy volunteers using positron emission tomography. Regional uptake was analyzed and quantified according to a 3-compartment model. Retention of both tracers in striatal regions of the parkinsonian patients were reduced compared with the healthy volunteers mainly in the putamen, while the caudate nuclleus was only mildly affected. The reductions were considerably less than the decrease previously reported postmortem for striatal dopamine content in the basal ganglia of patients with Parkinson's disease. A fairly constant ratio between 6-({sup 18}F)fluoro-L-dopa utilization and ({sup 11}C)-(+)-nomifensine binding in the caudate nucleus and the putamen were found in both groups unrelated to the size of the estimated parameters. This indicates that a limiting factor for the utilization of exogenous levodopa in Parkinsons's disease may be a reduced transport capacity for the amino acid into the dopaminergic terminals. (author).

  9. Effects of hyperoxia on 18F-fluoro-misonidazole brain uptake and tissue oxygen tension following middle cerebral artery occlusion in rodents: Pilot studies.

    Directory of Open Access Journals (Sweden)

    Tim D Fryer

    Full Text Available Mapping brain hypoxia is a major goal for stroke diagnosis, pathophysiology and treatment monitoring. 18F-fluoro-misonidazole (FMISO positron emission tomography (PET is the gold standard hypoxia imaging method. Normobaric hyperoxia (NBO is a promising therapy in acute stroke. In this pilot study, we tested the straightforward hypothesis that NBO would markedly reduce FMISO uptake in ischemic brain in Wistar and spontaneously hypertensive rats (SHRs, two rat strains with distinct vulnerability to brain ischemia, mimicking clinical heterogeneity.Thirteen adult male rats were randomized to distal middle cerebral artery occlusion under either 30% O2 or 100% O2. FMISO was administered intravenously and PET data acquired dynamically for 3hrs, after which magnetic resonance imaging (MRI and tetrazolium chloride (TTC staining were carried out to map the ischemic lesion. Both FMISO tissue uptake at 2-3hrs and FMISO kinetic rate constants, determined based on previously published kinetic modelling, were obtained for the hypoxic area. In a separate group (n = 9, tissue oxygen partial pressure (PtO2 was measured in the ischemic tissue during both control and NBO conditions.As expected, the FMISO PET, MRI and TTC lesion volumes were much larger in SHRs than Wistar rats in both the control and NBO conditions. NBO did not appear to substantially reduce FMISO lesion size, nor affect the FMISO kinetic rate constants in either strain. Likewise, MRI and TTC lesion volumes were unaffected. The parallel study showed the expected increases in ischemic cortex PtO2 under NBO, although these were small in some SHRs with very low baseline PtO2.Despite small samples, the apparent lack of marked effects of NBO on FMISO uptake suggests that in permanent ischemia the cellular mechanisms underlying FMISO trapping in hypoxic cells may be disjointed from PtO2. Better understanding of FMISO trapping processes will be important for future applications of FMISO imaging.

  10. Tomography by positrons emission: integral unit to the service of Mexico

    International Nuclear Information System (INIS)

    Lopez D, F.A.

    2005-01-01

    The applications of the Positron emission tomography (PET) together with the one radiopharmaceutical 2 - [ 18 F]-fluoro-2-deoxy-D-glucose in the area of the medical imaging is expanding quickly and it possesses a bigger impact at the moment in favor of those patient to who suffers an oncological, cardiac or neurological illness in Mexico. (Author)

  11. False-positive uptake on 2-[18F]-fluoro-2-deoxy-D-glucose (FDG) positron-emission tomography/computed tomography (PET/CT) in oncological imaging

    International Nuclear Information System (INIS)

    Culverwell, A.D.; Scarsbrook, A.F.; Chowdhury, F.U.

    2011-01-01

    With the increasing utilization of integrated positron-emission tomography/computed tomography (PET/CT) using the glucose analogue 2-[ 18 F]-fluoro-2-deoxy-D-glucose (FDG) in oncological imaging, it is important for radiologists and nuclear medicine physicians to be aware that FDG uptake is not specific for malignancy, as many different physiological variants and benign pathological conditions can also exhibit increased glucose metabolism. Such false-positive FDG uptake often arises outside the area of primary interest and may mimic malignant disease, thereby confounding accurate interpretation of PET/CT studies. With the use of illustrative clinical cases, this article will provide a systematic overview of potential interpretative pitfalls and illustrate how such unexpected findings can be appropriately evaluated.

  12. Schooling mediates brain reserve in Alzheimer's disease: findings of fluoro-deoxy-glucose-positron emission tomography.

    Science.gov (United States)

    Perneczky, R; Drzezga, A; Diehl-Schmid, J; Schmid, G; Wohlschläger, A; Kars, S; Grimmer, T; Wagenpfeil, S; Monsch, A; Kurz, A

    2006-09-01

    Functional imaging studies report that higher education is associated with more severe pathology in patients with Alzheimer's disease, controlling for disease severity. Therefore, schooling seems to provide brain reserve against neurodegeneration. To provide further evidence for brain reserve in a large sample, using a sensitive technique for the indirect assessment of brain abnormality (18F-fluoro-deoxy-glucose-positron emission tomography (FDG-PET)), a comprehensive measure of global cognitive impairment to control for disease severity (total score of the Consortium to Establish a Registry for Alzheimer's Disease Neuropsychological Battery) and an approach unbiased by predefined regions of interest for the statistical analysis (statistical parametric mapping (SPM)). 93 patients with mild Alzheimer's disease and 16 healthy controls underwent 18F-FDG-PET imaging of the brain. A linear regression analysis with education as independent and glucose utilisation as dependent variables, adjusted for global cognitive status and demographic variables, was conducted in SPM2. The regression analysis showed a marked inverse association between years of schooling and glucose metabolism in the posterior temporo-occipital association cortex and the precuneus in the left hemisphere. In line with previous reports, the findings suggest that education is associated with brain reserve and that people with higher education can cope with brain damage for a longer time.

  13. Clinical applications of positron emission tomography at Montreal Neurological Institute

    International Nuclear Information System (INIS)

    Morgan, P.P.

    1983-01-01

    The Montreal Neurological Institute occupies a leading position in positron emission tomography (PET) of the brain with the help of the following three techological gains: they have acquired a 'Therascan' positron emission tomograph manufactured by Atomic Energy of Canada Ltd.; also, a 'Baby Cyclotron' manufactured by Japan Steel Works Ltd.; and they have written a computer program to display the results in colour. Four short-lived isotopes are used; 11 C, 15 O, 18 F, 13 N. Studies of the oxygen uptake of tumours, their glucose metabolism (as monitored by 18 F labelled 2-fluoro-2-deoxyglucose), and their uptake of therapeutic agents, provide valuable research and diagnostic information. PET is also being used to study epilepsy and cerebrovascular disease

  14. Synthesis and organ distribution of [18F]Fluoro-Org 6141 in the rat: A potential glucocorticoid receptor ligand for positron emission tomography

    International Nuclear Information System (INIS)

    Visser, G.M.; Krugers, H.J.; Luurtsema, G.; Waarde, A. van; Elsinga, P.H.; DeKloet, E.R.; Groen, M.B.; Bohus, B.; Go, K.G.; Paans, A.M.J.; Korf, J.; Vaalburg, W.

    1995-01-01

    For the synthesis of [ 18 F]Fluoro-Org 6141 via a nucleophilic substitution reaction with 18 F - , the tosyl group was chosen as the leaving group because of its stability and excellent leaving group ability. The biodistribution of the high affinity and moderate lipophilicity (log P 2.66, calculated value) ligand [ 18 F]Fluoro-Org 6141 (specific activity 8.2 to 37 TBq/mmol, yield 10% at EOB) was examined in sham adrenalectomized (sADX) and adrenalectomized (ADX) male Wistar rats. Two days after ADX or sADX, the animals were anesthetized and 0.37 to 1.85 MBq of [ 18 F]Fluoro-Org 6141 was administered intravenously. Kinetics of 18 F activity uptake were monitored for 3 h using a stationary double-headed positron emission tomography (PET) camera, and the biodistribution was assessed by ex vivo determination of radioactivity in several tissues and different brain areas. One hour after injection of the radioligand, the bladder, kidney, liver, trachea, and bone of sADX animals contained more concentration on a wet weight basis than blood. Three hours post injection, radioactivity was retained in bladder, trachea, and bone. The accumulation of radioactivity in brain corresponded to the concentration of activity in the blood within the first hours after injection. ADX animals showed a higher uptake of 18 F activity in spleen, testes, and brain areas (hippocampus and brainstem) but a lower uptake in bone than sADX rats. PET scans suggested that 18 F activity uptake in the brain had not yet reached a maximum at this interval. Although [ 18 F]Fluoro-Org 6141 is not useful for PET studies of glucocorticoid receptors (GRs), the results obtained with this compound indicate a synthetic strategy suitable for the synthesis of high-affinity radioligands for GRs

  15. Monitoring of herpes simplex virus thymidine kinase enzyme activity using positron emission tomography

    NARCIS (Netherlands)

    Hospers, GAP; Calogero, Anna; van Waarde, A; Doze, P; Vaalburg, W; Mulder, NH; de Vries, EFJ

    2000-01-01

    9-[(1-[F-18]Fluoro-3-hydroxy-2-propoxy)methyl]guanine ([F-18]FHPG) wasevaluated as a tracer for noninvasive positron emission tomography (PET) imaging of herpes simplex virus type 1 thymidine kinase (HSV-tk) gene expression. C6 rat glioma cells with and without the HSV-tk gene were incubated with

  16. Tomography by positrons emission: integral unit to the service of Mexico; Tomografia por emision de positrones: unidad integral al servicio de Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Lopez D, F A [Unidad PET-Ciclotron, Facultad de Medicina, UNAM (Mexico)

    2005-07-01

    The applications of the Positron emission tomography (PET) together with the one radiopharmaceutical 2 - [{sup 18} F]-fluoro-2-deoxy-D-glucose in the area of the medical imaging is expanding quickly and it possesses a bigger impact at the moment in favor of those patient to who suffers an oncological, cardiac or neurological illness in Mexico. (Author)

  17. Alternative positron emission tomography with non-conventional positron emitters: effects of their physical properties on image quality and potential clinical applications

    International Nuclear Information System (INIS)

    Pagani, M.; Stone-Elander, S.; Larsson, S.A.

    1997-01-01

    The increasing amount of clinically relevant information obtained by positron emission tomography (PET), primarily with fluorine-18 labelled 2-deoxy-2-fluoro-d-glucose, has generated a demand for new routes for the widespread and cost-efficient use of positron-emitting radiopharmaceuticals. New dual-head single-photon emission tomography (SPET) cameras are being developed which offer coincidence detection with camera heads lacking a collimator or SPET imaging with specially designed collimators and additional photon shielding. Thus, not only satellite PET imaging units but also nuclear medicine units investing in these new SPET/PET systems need to examine all available alternatives for rational radionuclide supplies from host cyclotrons. This article examines 25 ''alternative'' positron-emitting radionuclides, discusses the impact of their decay properties on image quality and reviews methods for their production as well as for their application in imaging techniques. (orig.)

  18. Infective endocarditis detected by 18F-fluoro-2-deoxy-d-glucose positron emission tomography/computed tomography in a patient with occult infection

    Directory of Open Access Journals (Sweden)

    Chia-Lu Yeh

    2011-11-01

    Full Text Available Integrated 18F-fluoro-2-deoxy-d-glucose positron emission tomography/computed tomography (FDG PET/CT has been clinically used to detect infectious lesions. We present a case with pyrexia and bacteremia of unknown origin. Whole body FDG PET/CT was arranged to look for an occult source of infection and it revealed a focal lesion with increased FDG uptake in the mitral valve area. Under suspicion of infective endocarditis, transthoracic echocardiography was repeated and then the presence of linear vegetation over the calcified mitral annulus was confirmed. Ultimately, definite infective endocarditis was diagnosed according to the Duke criteria. The patient recovered after the antibiotic therapy. In our case, FDG PET/CT can help to localize the exact site of occult infection, thereby guiding additional testing and facilitating timely definitive diagnosis and therapy.

  19. Simultaneous emission and transmission scanning in positron emission tomography

    International Nuclear Information System (INIS)

    Satoh, Tomohiko; Tanaka, Kazumi; Kitamura, Keishi; Amano, Masaharu; Miura, Shuichi

    2001-01-01

    Examination by PET (positron emission tomography) scanning, following the dosage of 2-deoxy- 18 F fluoro-D-glucose (FDG), is positively utilized for the diagnosis of cancers, rather than for the purpose of studies. This is because the examination by FDG-PET (PET scanning following the dosage of FDG) ensures higher efficiency in discrimination of cancers, than conventional CT and PET. The method of whole body scanning by PET scanning following the dosage of FDG is effectively utilized not only for discrimination cancers, but also for determining the degree of malignancy of tumors and evaluating the methods of treatment of cancers. In conventional methods for examining the degree of malignancy of tumors and evaluating the methods of cancer treatment, it is necessary to correct for the gamma-ray attenuation, which requires a longer time for examination, increasing the physical and psychological pains of the patients. We have installed the simultaneous emission and transmission scanning capability into the HEADTOME-V of the Shimadzu SET-2000W Series positron emission tomographic scanning instruments, to establish an instrument that permits FDG-PET whole body scanning in actual clinical fields, with minimized physical and psychological pains of patients concerned, yet ensuring an outstandingly high examination efficiency. This report also presents some data obtained by this newly developed instrument and those obtained in practical applications. (author)

  20. Laparoscopic Scar: a mimicker of Sister Mary Joseph's nodule on positron emission tomography/CT

    International Nuclear Information System (INIS)

    Setty, B.; Blake, M.A.; Holalkere, N.S.; Blaszkowsky, L.S.; Fischman, A.

    2006-01-01

    Positron emission tomography/CT is an established imaging method in the diagnosis and staging of cancers. 18 F -fluoro-2-deoxy-D-glucose (FDG) is the most commonly used radiotracer in positron emission tomography/CT. It is a tumour viability agent and usually its uptake within a lesion reflects the presence of a viable tumour tissue. However, false-positive FDG uptake is known to occur in benign processes of either inflammatory or infectious aetiology. We describe FDG uptake at the site of laparoscopic scar that mimicked Sister Mary Joseph's nodule in a patient with gastric adenocarcinoma. Here, the knowledge of the patient's history and subtle imaging findings helped in accurate staging of the patient. In this case report, we emphasize the value of the knowledge of the patient history and awareness of different pitfalls of FDG to achieve a correct diagnosis on positron emission tomography/CT

  1. [18F]-Fluoro-Deoxy-Glucose Positron Emission Tomography Scan Should Be Obtained Early in Cases of Autoimmune Encephalitis

    Directory of Open Access Journals (Sweden)

    C. R. Newey

    2016-01-01

    Full Text Available Introduction. Autoimmune encephalitis (AE is a clinically challenging diagnosis with nonspecific neurological symptoms. Prompt diagnosis is important and often relies on neuroimaging. We present a case series of AE highlighting the importance of an early [18F]-fluoro-deoxy-glucose positron emission tomography (FDG-PET scan. Methods. Retrospective review of seven consecutive cases of autoimmune encephalitis. Results. All patients had both magnetic resonance imaging (MRI and FDG-PET scans. Initial clinical presentations included altered mental status and/or new onset seizures. Six cases had serum voltage-gated potassium channel (VGKC antibody and one had serum N-methyl-D-aspartate (NMDA antibody. MRI of brain showed mesial temporal lobe hyperintensity in five cases of VGKC. The other two patients with VGKC or NMDA AE had restiform body hyperintensity on MRI brain or a normal MRI, respectively. Mesial temporal lobe hypermetabolism was noted in three cases on FDG-PET, despite initial unremarkable MRI. Malignancy workup was negative in all patients. Conclusion. A high index of suspicion for AE should be maintained in patients presenting with cognitive symptoms, seizures, and limbic changes on neuroimaging. In cases with normal initial brain MRI, FDG-PET can be positive. Additionally, extralimbic hyperintensity on MRI may also be observed.

  2. [18F]-Fluoro-Deoxy-Glucose Positron Emission Tomography Scan Should Be Obtained Early in Cases of Autoimmune Encephalitis

    Science.gov (United States)

    Sarwal, A.; Hantus, S.

    2016-01-01

    Introduction. Autoimmune encephalitis (AE) is a clinically challenging diagnosis with nonspecific neurological symptoms. Prompt diagnosis is important and often relies on neuroimaging. We present a case series of AE highlighting the importance of an early [18F]-fluoro-deoxy-glucose positron emission tomography (FDG-PET) scan. Methods. Retrospective review of seven consecutive cases of autoimmune encephalitis. Results. All patients had both magnetic resonance imaging (MRI) and FDG-PET scans. Initial clinical presentations included altered mental status and/or new onset seizures. Six cases had serum voltage-gated potassium channel (VGKC) antibody and one had serum N-methyl-D-aspartate (NMDA) antibody. MRI of brain showed mesial temporal lobe hyperintensity in five cases of VGKC. The other two patients with VGKC or NMDA AE had restiform body hyperintensity on MRI brain or a normal MRI, respectively. Mesial temporal lobe hypermetabolism was noted in three cases on FDG-PET, despite initial unremarkable MRI. Malignancy workup was negative in all patients. Conclusion. A high index of suspicion for AE should be maintained in patients presenting with cognitive symptoms, seizures, and limbic changes on neuroimaging. In cases with normal initial brain MRI, FDG-PET can be positive. Additionally, extralimbic hyperintensity on MRI may also be observed. PMID:27559482

  3. Clinical cardiac positron emission tomography: State of the art

    International Nuclear Information System (INIS)

    Gould, K.L.

    1991-01-01

    Cardiac positron emission tomography (PET) has evolved rapidly from a relatively esoteric research tool into clinical applications providing unique, quantitative information on myocardial perfusion, metabolism, and cell membrane function and having a potentially significant impact on cardiovascular medicine. Although there are many different positron radionuclides for imaging diverse myocardial behavior, three radionuclides have reached accepted clinical utility. Cardiac PET using nitrogen-13-ammonia, rubidium-82, and fluoro-18-deoxyglucose has proved accurate and definitive in multiple university and private-practice sites for diagnosing and assessing severity and location of coronary artery disease in symptomatic or asymptomatic patients, for identifying injured but viable myocardium potentially salvageable by revascularization, and for ruling out clinically significant coronary artery stenosis with a high specificity in patients who might otherwise undergo coronary arteriography to document the absence of significant disease. 89 references

  4. The efficacy of preoperative positron emission tomography-computed tomography (PET-CT) for detection of lymph node metastasis in cervical and endometrial cancer: clinical and pathological factors influencing it.

    Science.gov (United States)

    Nogami, Yuya; Banno, Kouji; Irie, Haruko; Iida, Miho; Kisu, Iori; Masugi, Yohei; Tanaka, Kyoko; Tominaga, Eiichiro; Okuda, Shigeo; Murakami, Koji; Aoki, Daisuke

    2015-01-01

    We studied the diagnostic performance of (18)F-fluoro-2-deoxy-d-glucose-positron emission tomography/computed tomography in cervical and endometrial cancers with particular focus on lymph node metastases. Seventy patients with cervical cancer and 53 with endometrial cancer were imaged with (18)F-fluoro-2-deoxy-D-glucose-positron emission tomography/computed tomography before lymphadenectomy. We evaluated the diagnostic performance of (18)F-fluoro-2-deoxy-D-glucose-positron emission tomography/computed tomography using the final pathological diagnoses as the golden standard. We calculated the sensitivity, specificity, positive predictive value and negative predictive value of (18)F-fluoro-2-deoxy-D-glucose-positron emission tomography/computed tomography. In cervical cancer, the results evaluated by cases were 33.3, 92.7, 55.6 and 83.6%, respectively. When evaluated by the area of lymph nodes, the results were 30.6, 98.9, 55.0 and 97.0%, respectively. As for endometrial cancer, the results evaluated by cases were 50.0, 93.9, 40.0 and 95.8%, and by area of lymph nodes, 45.0, 99.4, 64.3 and 98.5%, respectively. The limitation of the efficacy was found out by analyzing it by the region of the lymph node, the size of metastatic node, the historical type of tumor in cervical cancer and the prevalence of lymph node metastasis. The efficacy of positron emission tomography/computed tomography regarding the detection of lymph node metastasis in cervical and endometrial cancer is not established and has limitations associated with the region of the lymph node, the size of metastasis lesion in lymph node and the pathological type of primary tumor. The indication for the imaging and the interpretation of the results requires consideration for each case by the pretest probability based on the information obtained preoperatively. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Design of steady-state positron emission tomography protocols for neurobehavioral studies: CO15O and 19Ne

    International Nuclear Information System (INIS)

    Kearfott, K.J.; Rottenberg, D.A.; Volpe, B.T.

    1983-01-01

    Although the [ 18 F]-2-fluoro-2-deoxyglucose positron emission tomographic technique for measuring regional glucose metabolic rate has been successfully employed for neurobehavioral studies, the long (greater than 30 min) equilibration time required may complicate the interpretation of experimental results. Positron emission tomography neurobehavioral protocols employing the continuous inhalation of CO 15 O and 19 Ne were developed for measuring regional cerebral blood flow during multiple control and stimulation periods. Timing, lung absorbed dose, statistical accuracy, and resolution were considered. Studies with 19 Ne require shorter equilibration and stimulation times than do CO 15 O studies but entail higher absorbed doses and yield poorer imaging statistics

  6. [18F]FDG and [18F]FLT positron emission tomography imaging following treatment with belinostat in human ovary cancer xenografts in mice

    DEFF Research Database (Denmark)

    Jensen, Mette Munk; Erichsen, Kamille Dumong; Johnbeck, Camilla Bardram

    2013-01-01

    Belinostat is a histone deacetylase inhibitor with anti-tumor effect in several pre-clinical tumor models and clinical trials. The aim of the study was to evaluate changes in cell proliferation and glucose uptake by use of 3'-deoxy-3'-[(18)F]fluorothymidine ([18F]FLT) and 2-deoxy-2-[(18)F]fluoro-......]fluoro-D-glucose ([18F]FDG) positron emission tomography (PET) following treatment with belinostat in ovarian cancer in vivo models....

  7. Brain metabolism in autism. Resting cerebral glucose utilization rates as measured with positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Rumsey, J.M.; Duara, R.; Grady, C.; Rapoport, J.L.; Margolin, R.A.; Rapoport, S.I.; Cutler, N.R.

    1985-05-01

    The cerebral metabolic rate for glucose was studied in ten men (mean age = 26 years) with well-documented histories of infantile autism and in 15 age-matched normal male controls using positron emission tomography and (F-18) 2-fluoro-2-deoxy-D-glucose. Positron emission tomography was completed during rest, with reduced visual and auditory stimulation. While the autistic group as a whole showed significantly elevated glucose utilization in widespread regions of the brain, there was considerable overlap between the two groups. No brain region showed a reduced metabolic rate in the autistic group. Significantly more autistic, as compared with control, subjects showed extreme relative metabolic rates (ratios of regional metabolic rates to whole brain rates and asymmetries) in one or more brain regions.

  8. Brain metabolism in autism. Resting cerebral glucose utilization rates as measured with positron emission tomography

    International Nuclear Information System (INIS)

    Rumsey, J.M.; Duara, R.; Grady, C.; Rapoport, J.L.; Margolin, R.A.; Rapoport, S.I.; Cutler, N.R.

    1985-01-01

    The cerebral metabolic rate for glucose was studied in ten men (mean age = 26 years) with well-documented histories of infantile autism and in 15 age-matched normal male controls using positron emission tomography and (F-18) 2-fluoro-2-deoxy-D-glucose. Positron emission tomography was completed during rest, with reduced visual and auditory stimulation. While the autistic group as a whole showed significantly elevated glucose utilization in widespread regions of the brain, there was considerable overlap between the two groups. No brain region showed a reduced metabolic rate in the autistic group. Significantly more autistic, as compared with control, subjects showed extreme relative metabolic rates (ratios of regional metabolic rates to whole brain rates and asymmetries) in one or more brain regions

  9. Cardiac positron emission tomography

    International Nuclear Information System (INIS)

    Eftekhari, M.; Ejmalian, G.

    2003-01-01

    Positron emission tomography is an intrinsically tool that provide a unique and unparalleled approach for clinicians and researchers to interrogate the heart noninvasively. The ability to label substances of physiological interest with positron-emitting radioisotopes has permitted insight into normal blood flow and metabolism and the alterations that occur with disease states. Positron emission tomography of the heart has evolved as a unique, noninvasive approach for the assessment of myocardial perfusion, metabolism, and function. Because of the intrinsic quantitative nature of positron emission tomography measurements as well as the diverse compounds that can be labeled with positron- emitting radioisotopes, studies with positron emission tomography have provided rich insight into the physiology of the heart under diverse conditions

  10. Positron emission tomography

    International Nuclear Information System (INIS)

    Reivich, M.; Alavi, A.

    1985-01-01

    This book contains 24 selections. Some of the titles are: Positron Emission Tomography Instrumentation, Generator Systems for Positron Emitters, Reconstruction Algorithms, Cerebral Glucose Consumption: Methodology and Validation, Cerebral Blood Flow Tomography Using Xenon-133 Inhalation: Methods and Clinical Applications, PET Studies of Stroke, Cardiac Positron Emission Tomography, and Use of PET in Oncology

  11. Positron emission tomography in the management of cervix cancer patients

    International Nuclear Information System (INIS)

    Bonardel, G.; Gontier, E.; Soret, M.; Dechaud, C.; Fayolle, M.; Foehrenbach, H.; Chargari, C.; Bauduceau, O.

    2009-01-01

    Since its introduction in clinical practice in the 1990 s, positron emission tomography (PET), usually with 18 F-fluoro-2-deoxy-D-glucose ( 18 F-F.D.G.), has become an important imaging modality in patients with cancer. For cervix carcinoma, F.D.G.-PET is significantly more accurate than computed tomography (CT) and is recommended for loco-regional lymph node and extra pelvic staging. The metabolic dimension of the technique provides additional prognostic information. Ongoing studies now concentrate on more advanced clinical applications, such as the planning of radiotherapy, the response evaluation after the induction of therapy, the early detection of recurrence. Technical innovations, such as PET cameras with better spatial resolution and hybrid positron emission tomography/computed tomography (PET-CT), available now on the whole territory, provide both anatomic and metabolic information in the same procedure. From the point of view of biological metabolism, new radiopharmaceutical probes are being developed. Those hold promise for future refinements in this field. This article reviews the current applications of F.D.G.-PET in patients with cervix cancer. (authors)

  12. [Development of analysis software package for the two kinds of Japanese fluoro-d-glucose-positron emission tomography guideline].

    Science.gov (United States)

    Matsumoto, Keiichi; Endo, Keigo

    2013-06-01

    Two kinds of Japanese guidelines for the data acquisition protocol of oncology fluoro-D-glucose-positron emission tomography (FDG-PET)/computed tomography (CT) scans were created by the joint task force of the Japanese Society of Nuclear Medicine Technology (JSNMT) and the Japanese Society of Nuclear Medicine (JSNM), and published in Kakuigaku-Gijutsu 27(5): 425-456, 2007 and 29(2): 195-235, 2009. These guidelines aim to standardize PET image quality among facilities and different PET/CT scanner models. The objective of this study was to develop a personal computer-based performance measurement and image quality processor for the two kinds of Japanese guidelines for oncology (18)F-FDG PET/CT scans. We call this software package the "PET quality control tool" (PETquact). Microsoft Corporation's Windows(™) is used as the operating system for PETquact, which requires 1070×720 image resolution and includes 12 different applications. The accuracy was examined for numerous applications of PETquact. For example, in the sensitivity application, the system sensitivity measurement results were equivalent when comparing two PET sinograms obtained from the PETquact and the report. PETquact is suited for analysis of the two kinds of Japanese guideline, and it shows excellent spec to performance measurements and image quality analysis. PETquact can be used at any facility if the software package is installed on a laptop computer.

  13. Development of radiotracers for imaging NR2B subtype NMDA receptors with positron emission tomography; Developpement de radiotraceurs pour la visualisation des recepteurs NMDA de sous-type NR2B par tomographie par emission de positons

    Energy Technology Data Exchange (ETDEWEB)

    Labas, R

    2007-07-01

    The aim of this thesis was to develop new radioactive tracers for imaging NR2B subtype NMDA receptors with positron emission tomography. Several compounds including 4-(4-fluoro-benzyl)piperidine and presenting interesting in vivo biological properties were the object of a labelling with a positrons emitter atom ({sup 11}C or {sup 18}F)

  14. Synthesis of 2-[18F]fluoro-L-tyrosine via regiospecific fluoro-de-stannylation

    International Nuclear Information System (INIS)

    Hess, E.; Sichler, S.; Kluge, A.; Coenen, H.H.

    2002-01-01

    2-[ 18 F]Fluoro-L-tyrosine is a fluorine labelled amino acid, known to be incorporated into newly synthesised proteins, rendering it a potentially suitable tracer to image protein metabolism in vivo using positron emission tomography. For the electrophilic preparation of 2-[ 18 F]fluoro-L-tyrosine three protected 2-trialkylstannyl tyrosine derivatives have been synthesised for the first time as precursors. While O,N-di-Boc-2-triethylstannyl-L-tyrosine ethylester has proved to be suitable as precursor for radiosynthesis, imidazolidinon-derivatives of 2-triaklylstannyl tyrosine have not because of difficult fast hydrolysis of a phenolic O-methyl protective group. The di-Boc-tin derivative of tyrosine ethylester readily reacted with [ 18 F]F 2 , which was prepared via the 18 O(p,n) 18 F nuclear reaction. 2-[ 18 F]Fluoro-L-tyrosine was isolated after full deprotection with aqueous hydrobromic acid and HPLC purification with activities of 1.41±0.32 GBq. The isomeric and enantiomeric purity is high (both >99%). The preparation procedure is facile and easy to automate. The chemical yields of this fluoro-de-stannylation reaction as well as of the synthesis of 6-[ 18 F]fluoro-L-dopa, determined with an analogous precursor and non-radioactive fluorine under identical conditions, amounted to 42.7±1.6% and 60.2±2.8%, respectively

  15. Plasma concentrations of misonidazole

    Energy Technology Data Exchange (ETDEWEB)

    Notter, G; Rylander, U; Turesson, I

    1980-10-01

    The plasma concentrations of misonidazole doses between 0.6 and 2.0 g/m/sup 2/ were analyzed in respect to the variation within the same patient and between different patients. Peak plasma levels were observed after 2 hours. The mean plasma levels of misonidazole only at 3 hours were 23.8, 47.0 and 76.5 ..mu..g/ml after misonidazole doses of 0.6, 1.2 g/m/sup 2/, respectively. The half-life of misonidazole only was found to be 8.2 hours for women and 10.5 for men. Good linearity between plasma levels and drug doses was observed after administration of different single doses to the same patient within the dose range 0.6 to 2.0 g/m/sup 2/.

  16. Misonidazole-glutathione conjugates in CHO cells

    International Nuclear Information System (INIS)

    Varghese, A.J.; Whitmore, G.F.

    1984-01-01

    Misonidazole, after reduction to the hydroxylamine derivative, reacts with glutathione (GSH) under physiological conditions. The reaction product has been identified as a mixture of two isomeric conjugates. When water soluble extracts of CHO cells exposed to misonidazole under hypoxic conditions are subjected to HPLC analysis, misonidazole derivatives, having the same chromatographic properties as the GSH-MISO conjugates, were detected. When CHO cells were incubated with misonidazole in the presence of added GSH, a substantial increase in the amount of the conjugate was detected. When extracts of CHO cells exposed to misonidazole under hypoxia were subsequently exposed to GSH, an increased formation of the conjugate was observed. A rearrangement product of the hydroxylamine derivative of misonidazole is postulated as the reactive intermediate responsible for the formation of the conjugate

  17. Comparison of 18F-fluoro-L-DOPA, 18F-fluoro-deoxyglucose, and 18F-fluorodopamine PET and 123I-MIBG scintigraphy in the localization of pheochromocytoma and paraganglioma.

    NARCIS (Netherlands)

    Timmers, H.J.L.M.; Chen, C.C.; Carrasquillo, J.A.; Whatley, M.; Ling, A.; Havekes, B.; Eisenhofer, G.; Martiniova, L.; Adams, K.T.; Pacak, K.

    2009-01-01

    CONTEXT: Besides (123)I-metaiodobenzylguanidine (MIBG), positron emission tomography (PET) agents are available for the localization of paraganglioma (PGL), including (18)F-3,4-dihydroxyphenylalanine (DOPA), (18)F-fluoro-2-deoxy-D-glucose ((18)F-FDG), and (18)F-fluorodopamine ((18)F-FDA). OBJECTIVE:

  18. Tracers tor the investigation of cerebral presynaptic dopaminergic function with positron emission tomography

    International Nuclear Information System (INIS)

    Firnau, G.; Chirakal, R.; Nahmias, C.; Garnett, E.S.

    1991-01-01

    Two pharmacologic concepts, open-quotes metabolic precursorsclose quotes and open-quotes enzyme inhibitorsclose quotes have been applied to the design of PET tracers for the metabolic aspects of the neurotransmitter dopamine. As the result, highly useful, positron-emitting radiotracers have been developed with which to visualize and measure the cerebral distribution and metabolism of dopaminergic neurons. Positron emitter-labeled DOPA, particularly 6-[ 18 F]fluoro-L-DOPA, is being used to obtain information about the neurochemical anatomy of the dopamine system, and potentially, the rate constant of dopamine biosynthesis. 6-[ 18 F]Fluoro-L- meta-tyrosine delineates the dopaminergic structures even better than 6-[ 18 F]fluoro-L-DOPA but cannot provide kinetic information about dopamine biosynthesis. The in vivo activity of the enzyme aromatic L-aminoacid decarboxylase and that of monoamine oxidase types A and B can be measured with a-fluoro-methyl-6-[ 18 F]fluoro-L-DOPA, [ 11 C]clorgyline and L-[ 11 C]deprenyl, respectively. Thus, neuropharmacologic investigations of human presynaptic dopamine pharmacology are now possible in vivo

  19. Positron emission tomography

    International Nuclear Information System (INIS)

    Paans, A.M.J.

    1981-01-01

    Positron emitting radiopharmaceuticals have special applications in in-vivo studies of biochemical processes. The combination of a cyclotron for the production of radionuclides and a positron emission tomograph for the registration of the distribution of radioactivity in the body enables the measurement of local radioactivity concentration in tissues, and opens up new possibilities in the diagnosis and examination of abnormalities in the metabolism. The principles and procedures of positron emission tomography are described and the necessary apparatus considered, with emphasis on the positron camera. The first clinical applications using 55 Co bloemycine for tumor detection are presented. (C.F.)

  20. Clinical value of whole body fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography in the detection of metastatic bladder cancer.

    Science.gov (United States)

    Yang, Zhongyi; Pan, Lingling; Cheng, Jingyi; Hu, Silong; Xu, Junyan; Ye, Dingwei; Zhang, Yingjian

    2012-07-01

    To investigate the value of whole-body fluorine-18 2-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography for the detection of metastatic bladder cancer. From December 2006 to August 2010, 60 bladder cancer patients (median age 60.5 years old, range 32-96) underwent whole body positron emission tomography/computed tomography positron emission tomography/computed tomography. The diagnostic accuracy was assessed by performing both organ-based and patient-based analyses. Identified lesions were further studied by biopsy or clinically followed for at least 6 months. One hundred and thirty-four suspicious lesions were identified. Among them, 4 primary cancers (2 pancreatic cancers, 1 colonic and 1 nasopharyngeal cancer) were incidentally detected, and the patients could be treated on time. For the remaining 130 lesions, positron emission tomography/computed tomography detected 118 true positive lesions (sensitivity = 95.9%). On the patient-based analysis, the overall sensitivity and specificity resulted to be 87.1% and 89.7%, respectively. There was no difference of sensitivity and specificity in patients with or without adjuvant treatment in terms of detection of metastatic sites by positron emission tomography/computed tomography. Compared with conventional imaging modality, positron emission tomography/computed tomography correctly changed the management in 15 patients (25.0%). Positron emission tomography/computed tomography has excellent sensitivity and specificity in the detection of metastatic bladder cancer and it provides additional diagnostic information compared to standard imaging techniques. © 2012 The Japanese Urological Association.

  1. Clinical value of whole body fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography in the detection of metastatic bladder cancer

    International Nuclear Information System (INIS)

    Yang Zhongyi; Pan Lingling; Cheng Jingyi; Hu Silong; Xu Junyan; Zhang Yingjian; Ye Dingwei

    2012-01-01

    The objective of this study was to investigate the value of whole-body fluorine-18 2-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography for the detection of metastatic bladder cancer. From December 2006 to August 2010, 60 bladder cancer patients (median age 60.5 years old, range 32-96) underwent whole body positron emission tomography/computed tomography positron emission tomography/computed tomography. The diagnostic accuracy was assessed by performing both organ-based and patient-based analyses. Identified lesions were further studied by biopsy or clinically followed for at least 6 months. One hundred and thirty-four suspicious lesions were identified. Among them, 4 primary cancers (2 pancreatic cancers, 1 colonic and 1 nasopharyngeal cancer) were incidentally detected, and the patients could be treated on time. For the remaining 130 lesions, positron emission tomography/computed tomography detected 118 true positive lesions (sensitivity=95.9%). On the patient-based analysis, the overall sensitivity and specificity resulted to be 87.1% and 89.7%, respectively. There was no difference of sensitivity and specificity in patients with or without adjuvant treatment in terms of detection of metastatic sites by positron emission tomography/computed tomography. Compared with conventional imaging modality, positron emission tomography/computed tomography correctly changed the management in 15 patients (25.0%). Positron emission tomography/computed tomography has excellent sensitivity and specificity in the detection of metastatic bladder cancer and it provides additional diagnostic information compared to standard imaging techniques. (author)

  2. Fluorine-18 fluoro-2-deozyglucose positron emission tomography in recurrent rectal cancer: relation to tumour size and cellularity

    International Nuclear Information System (INIS)

    Ito, Kengo; Kato, Takashi; Ohta, Tyohiro; Tadokoro, Masanori; Yamada, Tetsuya; Ikeda, Mitsuru; Nishino, Masanari; Ishigaki, Takeo; Ito, Katsuiki; Gambhir, S.

    1996-01-01

    The aim of this study was to assess the value of fluorine-18 fluoro-2-deoxyglucose (FDG) positron emission tomography in patients with recurrent rectal cancer, in relation to tumour size and cellularity. Thirty-seven patients (21 mean and 16 women; mean age, 55.4±9.58 years) with suspected recurrence of rectal cancer were studied. FDG uptake was quantified by the differential absorption ratio (DAR). In 29 patients magnetic resonance imaging was also performed. To evaluate the signal intensity of the lesion, the lesion to muscle signal intensity ratio (SIR) were calculated on T2-weighted images. In seven patients who received surgical treatment the DAR and SIR were compared with the tumour cellularity. All 32 patients with confirmed recurrence showed increased FDG accumulation in the mass (DAR=4.57±1.89) in comparison with low FDG accumulation in five patients with scar (DAR=1.17±0.43). There was a significant correlation (r=0.661, P<0.001) between the DAR and the tumour diameter. There was no correlation between the DAR and SIR, whereas there was a significant correlation (r=0.565, P<0.01) between the DAR corrected using count recovery coefficient (DAR*) and SIR. In the histopathological findings there was a tendency for the DAR* and SIR to correlate with tumour cellularity. It is concluded that the DAR of recurrent rectal cancer should be evaluated taking into consideration the tumour size and cellularity. (orig.)

  3. Positron emission tomography in degenerative disorders of the dopaminergic system

    Energy Technology Data Exchange (ETDEWEB)

    Karbe, H; Holthoff, V; Huber, M; Herholz, K; Wienhard, K; Wagner, R; Heiss, W D [Universitaetsklinik fuer Neurologie und Max-Planck-Institut fuer neurologische Forschung, Koeln (Germany)

    1992-01-01

    21 patients who had Parkinson's disease (PD), PD plus dementia of Alzheimer type (PDAT) or progressive supranuclear palsy (PSP), were studied with positron emission tomography (PET) using ({sup 18}F)-2-fluoro-2-deoxy-D-glucose (FDG). In one patient with strictly unilateral PD side differences in striatal dopa uptake were studied with 6-({sup 18}F)fluoro-L-dopa (F-dopa). In patients with PD PET with FDG did not show any significant change in regional cerebral metabolic rates for glucose (rCMR(Glu)). In PDAT glucose metabolism was generally reduced, the most severe decrease was found in parietal cortex. The metabolic pattern was similar to that typically found in patients with Alzheimer's disease (AD). In the patient with strictly unilateral PD rCMR(Glu) was normal, F-dopa PET, however, revealed a distinct reduction of dopa uptake in the contralateral putamen. In PSP glucose metabolism was significantly decreased in subcortical regions (caudatum, putamen and brainstem) and in frontal cortex. Thus PET demonstrated a clear difference of metabolic pattern between PDAT and PSP. (authors).

  4. 2-[18F]fluoro-A-85380, an in vivo tracer for the nicotinic acetylcholine receptors

    International Nuclear Information System (INIS)

    Horti, Andrew G.; Scheffel, Ursula; Koren, Andrei O.; Ravert, Hayden T.; Mathews, William B.; Musachio, John L.; Finley, Paige A.; London, Edythe D.; Dannals, Robert F.

    1998-01-01

    The in vivo brain regional distribution of 2-[ 18 F]fluoro-A-85380, a novel tracer for positron emission tomographic (PET) studies, followed the regional densities of brain nAChRs reported in the literature. Evidence of binding to nAChRs and high specificity of the binding in vivo was demonstrated by inhibition with nAChR selective ligands as well as with unlabeled 2-fluoro-A-85380. A preliminary toxicology study of the 2-fluoro-A-85380 showed a relatively low biological effect. 2-[ 18 F]Fluoro-A-85380 holds promise as a useful radiotracer for imaging of nAChRs with PET

  5. Positron emission tomography

    International Nuclear Information System (INIS)

    Wienhard, K.; Heiss, W.D.

    1984-01-01

    The principles and selected clinical applications of positron emission tomography are described. In this technique a chemical compound is labeled with a positron emitting isotope and its biochemical pathway is traced by coincidence detection of the two annihilation photons. The application of the techniques of computed tomography allows to reconstruct the spatial distribution of the radioactivity within a subject. The 18 F-deoxyglucose method for quantitative measurement of local glucose metabolism is discussed in order to illustrate the possibilities of positron emission tomography to record physiological processes in vivo. (orig.) [de

  6. Crossed cerebellar diaschisis. A positron emission tomography study with L-[methyl-11C]methionine and 2-deoxy-2-[18F]fluoro-D-glucose

    International Nuclear Information System (INIS)

    Kajimoto, Katsufumi; Oku, Naohiko; Kimura, Yasuyuki

    2007-01-01

    Crossed cerebellar diaschisis (CCD) is defined as a depression of blood flow and oxidative metabolism of glucose in the cerebellum contralateral to a supratentorial brain lesion, as detected with positron emission tomography (PET) and single photon emission computed tomography. We examined whether L-[methyl- 11 C]methionine (MET) uptake is affected in CCD. In 12 patients with a unilateral supratentorial brain tumor, we evaluated the uptake of 2-deoxy-2-[ 18 F]fluoro-D-glucose (FDG) and MET in the cerebellar hemispheres by means of PET. Asymmetry index (AI) was defined as a difference in the average count between the ipsilateral and contralateral cerebellar hemispheres divided by the average count in both cerebellar hemispheres. Patients with AI of FDG PET more than 0.1 and those with AI equal to 0.1 or less than 0.1 were classified as CCD-positive and CCD-negative, respectively. Six patients were CCD-positive and others were CCD-negative in the FDG PET study. Between CCD-positive and CCD-negative patients, mean AI of MET was not significantly different (0.017±0.023 and 0.014±0.039, respectively). Different from glucose metabolism, cerebellar MET uptake was not affected in CCD. The present study may indicate that cerebellar MET uptake is independent of suppression of cerebellar neuronal activity. (author)

  7. 2-[{sup 18}F]fluoro-A-85380, an in vivo tracer for the nicotinic acetylcholine receptors

    Energy Technology Data Exchange (ETDEWEB)

    Horti, Andrew G.; Scheffel, Ursula; Koren, Andrei O.; Ravert, Hayden T.; Mathews, William B.; Musachio, John L.; Finley, Paige A.; London, Edythe D.; Dannals, Robert F

    1998-10-01

    The in vivo brain regional distribution of 2-[{sup 18}F]fluoro-A-85380, a novel tracer for positron emission tomographic (PET) studies, followed the regional densities of brain nAChRs reported in the literature. Evidence of binding to nAChRs and high specificity of the binding in vivo was demonstrated by inhibition with nAChR selective ligands as well as with unlabeled 2-fluoro-A-85380. A preliminary toxicology study of the 2-fluoro-A-85380 showed a relatively low biological effect. 2-[{sup 18}F]Fluoro-A-85380 holds promise as a useful radiotracer for imaging of nAChRs with PET.

  8. Positron emission tomography

    International Nuclear Information System (INIS)

    Iio, Masahiro

    1982-01-01

    Utilization of positron emission tomography was reviewed in relation to construction and planned construction of small-size medical cyclotrons, planned construction of positron cameras and utilization of short-lived radionuclides. (Chiba, N.)

  9. A phase I study on stereotactic body radiotherapy of liver metastases based on functional treatment planning using positron emission tomography with 2-[(18)F]fluoro-2-deoxy-d-galactose

    DEFF Research Database (Denmark)

    Fode, Mette Marie; Bak-Fredslund, Kirstine; Petersen, Jørgen Baltzer

    2017-01-01

    BACKGROUND AND PURPOSE: The galactose analog 2-[18F]fluoro-2-deoxy-d-galactose (FDGal) is used for quantification of regional hepatic metabolic capacity by functional positron emission tomography computerized tomography (PET/CT). In the present study, FDGal PET/CT was used for functional treatment...... planning (FTP) of stereotactic body radiotherapy (SBRT) of liver metastases with the aim of minimizing radiation dose to the best functioning liver tissue. MATERIAL AND METHODS: Fourteen patients referred for SBRT had FDGal PET/CT performed before and one month after the treatment. The planning CT...... and the FDGal PET/CT images were deformable co-registered. RESULTS: A reduction in the mean dose of approximately 2 Gy to the best functioning sub-volumes was obtained. One patient developed grade 2 acute morbidity and no patients experienced grade 3 or higher acute morbidities. The regional hepatic metabolic...

  10. Radiation-induced energy migration within solid DNA: The role of misonidazole as an electron trap

    International Nuclear Information System (INIS)

    Al-Kazwini, A.T.; O'Neill, P.; Adams, G.E.; Fielden, E.M.

    1990-01-01

    The in-pulse luminescence emission from solid DNA produced upon irradiation with electron pulses of energy below 260 keV has been investigated in vacuo at 293 K to gain an insight into the existence of radiation-induced charge/energy migration within DNA. The DNA samples contained misonidazole in the range 3 to 330 base pairs per misonidazole molecule. Under these conditions greater than 90% of the total energy is deposited in the DNA. The in-pulse radiation-induced luminescence spectrum of DNA was found to be critically dependent upon the misonidazole content of DNA. The luminescence intensity from the mixtures decreases with increasing content of misonidazole, and at the highest concentration, the intensity at 550 nm is reduced to 50% of that from DNA only. In the presence of 1 atm of oxygen, the observed emission intensity from DNA in the wavelength region 350-575 was reduced by 35-40% compared to that from DNA in vacuo. It is concluded that electron migration can occur in solid mixtures of DNA over a distance of up to about 100 base pairs

  11. Early Treatment Response Monitoring Using 2-Deoxy-2-[18F]fluoro-D-glucose Positron Emission Tomography Imaging during Fractionated Radiotherapy of Head Neck Cancer Xenografts

    Directory of Open Access Journals (Sweden)

    Jiayi Huang

    2014-01-01

    Full Text Available Background. To determine the optimal timing and analytic method of 2-deoxy-2-[18F]fluoro-D-glucose positron emission tomography (PET imaging during fractionated radiotherapy (RT to predict tumor control. Methods. Ten head neck squamous cell carcinoma xenografts derived from the UT-14-SCC cell line were irradiated with 50 Gy at 2 Gy per day over 5 weeks. Dynamic PET scans were acquired over 70 minutes at baseline (week 0 and weekly for seven weeks. PET data were analyzed using standard uptake value (SUV, retention index (RI, sensitivity factor (SF, and kinetic index (Ki. Results. Four xenografts had local failure (LF and 6 had local control. Eighty scans from week 0 to week 7 were analyzed. RI and SF after 10 Gy appeared to be the optimal predictors for LF. In contrast, SUV and Ki during RT were not significant predictors for LF. Conclusion. RI and SF of PET obtained after the first week of fractionated RT were the optimal methods and timing to predict tumor control.

  12. Positron emission tomography/computed tomography surveillance in patients with Hodgkin lymphoma in first remission has a low positive predictive value and high costs.

    Science.gov (United States)

    El-Galaly, Tarec Christoffer; Mylam, Karen Juul; Brown, Peter; Specht, Lena; Christiansen, Ilse; Munksgaard, Lars; Johnsen, Hans Erik; Loft, Annika; Bukh, Anne; Iyer, Victor; Nielsen, Anne Lerberg; Hutchings, Martin

    2012-06-01

    The value of performing post-therapy routine surveillance imaging in patients with Hodgkin lymphoma is controversial. This study evaluates the utility of positron emission tomography/computed tomography using 2-[18F]fluoro-2-deoxyglucose for this purpose and in situations with suspected lymphoma relapse. We conducted a multicenter retrospective study. Patients with newly diagnosed Hodgkin lymphoma achieving at least a partial remission on first-line therapy were eligible if they received positron emission tomography/computed tomography surveillance during follow-up. Two types of imaging surveillance were analyzed: "routine" when patients showed no signs of relapse at referral to positron emission tomography/computed tomography, and "clinically indicated" when recurrence was suspected. A total of 211 routine and 88 clinically indicated positron emission tomography/computed tomography studies were performed in 161 patients. In ten of 22 patients with recurrence of Hodgkin lymphoma, routine imaging surveillance was the primary tool for the diagnosis of the relapse. Extranodal disease, interim positron emission tomography-positive lesions and positron emission tomography activity at response evaluation were all associated with a positron emission tomography/computed tomography-diagnosed preclinical relapse. The true positive rates of routine and clinically indicated imaging were 5% and 13%, respectively (P = 0.02). The overall positive predictive value and negative predictive value of positron emission tomography/computed tomography were 28% and 100%, respectively. The estimated cost per routine imaging diagnosed relapse was US$ 50,778. Negative positron emission tomography/computed tomography reliably rules out a relapse. The high false positive rate is, however, an important limitation and a confirmatory biopsy is mandatory for the diagnosis of a relapse. With no proven survival benefit for patients with a pre-clinically diagnosed relapse, the high costs and low

  13. Positron emission tomography

    International Nuclear Information System (INIS)

    Chandrasekhar, Preethi; Himabindu, Pucha

    2000-01-01

    Positron Emission Tomography (PET) is a non-invasive nuclear imaging technique used to study different molecular pathways and anatomical structures. PET has found extensive applications in various fields of medicine viz. cardiology, oncology, psychiatry/psychology, neuro science and pulmonology. This study paper basically deals with the physics, chemistry and biology behind the PET technique. It discusses the methodology for generation of the radiotracers responsible for emission of positrons and the annihilation and detection techniques. (author)

  14. Positron emission tomography

    International Nuclear Information System (INIS)

    Dvorak, O.

    1989-01-01

    The principle is briefly described of positron emission tomography, and its benefits and constraints are listed. It is emphasized that positron emission tomography (PET) provides valuable information on metabolic changes in the organism that are otherwise only very difficult to obtain, such as brain diagnosis including relationships between mental disorders and the physiology and pathophysiology of the brain. A PET machine is to be installed in Czechoslovakia in the near future. (L.O.)

  15. Influence of 2-(18F) fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography on recurrent ovarian cancer diagnosis and on selection of patients for secondary cytoreductive surgery

    DEFF Research Database (Denmark)

    Risum, Signe; Høgdall, Claus; Markova, Elena

    2009-01-01

    physical examination, US, or increasing cancer antigen 125 (CA125) level (>50 U/mL or >15% above baseline level). Recurrent OC was diagnosed 58 times in 52 patients. The sensitivities of US, CT, and PET/CT for diagnosing recurrence were 66% (P = 0.003), 81% (P = 0.0001), and 97% (P ...The objective of this prospective study was to compare the sensitivities and the specificities of combined 2-(F) fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (PET/CT), abdominal/transvaginal ultrasound (US), and CT for diagnosing recurrent ovarian cancer (OC......) and to evaluate the influence of PET/CT on referral of patients with solitary recurrence to secondary cytoreductive surgery. From April 2005 to November 2007, 60 patients were consecutively included to PET/CT 68 times. The inclusion criteria were remission of 3 months or longer and recurrent OC suspected from...

  16. 2-[18 F]fluoro-2-deoxy-d-glucose (FDG) positron-emission tomography (PET) findings of chronic expanding intrapericardial hematoma: a potential interpretive pitfall that mimics a malignant tumor

    Science.gov (United States)

    2013-01-01

    A 77-year-old man who had undergone mitral valve replacement 5 years previously presented with an intrapericardial mass. Computed tomography and magnetic resonance imaging showed that the mass lesion contained hematoma components. Positron-emission tomography (PET) with 2-[18 F] fluoro-2-deoxy-d-glucose (FDG) revealed uptake in the peripheral rim of the mass. These findings suggested the presence of hematoma associated with a malignant lesion. Surgical resection was performed, and the histological diagnosis was chronic expanding intrapericardial hematoma without neoplastic changes. Chronic expanding intrapericardial hematoma is a rare disease but should be considered when an expanding mass is found in a patient after cardiac surgery. The FDG-PET findings of chronic expanding hematomas, including FDG uptake in the peripheral rim of the mass as a result of inflammation, should be recognized as a potential interpretive pitfall that mimics a malignant tumor. PMID:23324446

  17. Positron emission tomography

    NARCIS (Netherlands)

    Paans, AMJ

    Positron Emission Tomography (PET) is a method for determining biochemical and physiological processes in vivo in a quantitative way by using radiopharmaceuticals labelled with positron emitting radionuclides as C-11, N-13, O-15 and F-18 and by measuring the annihilation radiation using a

  18. Positron emission tomography/computed tomography and biomarkers for early treatment response evaluation in metastatic colon cancer

    DEFF Research Database (Denmark)

    Engelmann, Bodil E.; Loft, Annika; Kjær, Andreas

    2014-01-01

    BACKGROUND: Treatment options for metastatic colon cancer (mCC) are widening. We prospectively evaluated serial 2-deoxy-2-[18F]fluoro-d-glucose positron-emission tomography/computed tomography (PET/CT) and measurements of tissue inhibitor of metalloproteinases-1 (TIMP-1), carcinoembryonic antigen...... evaluated by PET/CT before treatment, after one and four treatment series. Morphological and metabolic response was independently assessed according to Response Evaluation Criteria in Solid Tumors and European Organization for Research and Treatment of Cancer PET criteria. Plasma TIMP-1, plasma u...

  19. Positron emission tomography

    International Nuclear Information System (INIS)

    Yamamoto, Y.L.; Thompson, C.J.; Diksic, M.; Meyer, E.; Feindel, W.H.

    1984-01-01

    One of the most exciting new technologies introduced in the last 10 yr is positron emission tomography (PET). PET provides quantitative, three-dimensional images for the study of specific biochemical and physiological processes in the human body. This approach is analogous to quantitative in-vivo autoradiography but has the added advantage of permitting non-invasive in vivo studies. PET scanning requires a small cyclotron to produce short-lived positron emitting isotopes such as oxygen-15, carbon-11, nitrogen-13 and fluorine-18. Proper radiochemical facilities and advanced computer equipment are also needed. Most important, PET requires a multidisciplinary scientific team of physicists, radiochemists, mathematicians, biochemists and physicians. The most recent trends are reviewed in the imaging technology, radiochemistry, methodology and clinical applications of positron emission tomography. (author)

  20. Simulation of the annihilation emission of galactic positrons; Modelisation de l'emission d'annihilation des positrons Galactiques

    Energy Technology Data Exchange (ETDEWEB)

    Gillard, W

    2008-01-15

    Positrons annihilate in the central region of our Galaxy. This has been known since the detection of a strong emission line centered on an energy of 511 keV in the direction of the Galactic center. This gamma-ray line is emitted during the annihilation of positrons with electrons from the interstellar medium. The spectrometer SPI, onboard the INTEGRAL observatory, performed spatial and spectral analyses of the positron annihilation emission. This thesis presents a study of the Galactic positron annihilation emission based on models of the different interactions undergone by positrons in the interstellar medium. The models are relied on our present knowledge of the properties of the interstellar medium in the Galactic bulge, where most of the positrons annihilate, and of the physics of positrons (production, propagation and annihilation processes). In order to obtain constraints on the positrons sources and physical characteristics of the annihilation medium, we compared the results of the models to measurements provided by the SPI spectrometer. (author)

  1. Improving 18F-Fluoro-D-Glucose-Positron Emission Tomography/Computed Tomography Imaging in Alzheimer's Disease Studies

    International Nuclear Information System (INIS)

    Knešaurek, Karin

    2015-01-01

    The goal was to improve Alzheimer's 2-deoxy-2- 18 F-fluoro-D-glucose ( 18 F FDG)-positron emission tomography (PET)/computed tomography (CT) imaging through application of a novel, hybrid Fourier-wavelet windowed Fourier transform (WFT) restoration technique, in order to provide earlier and more accurate clinical results. General Electric Medical Systems downward-looking sonar PET/CT 16 slice system was used to acquire studies. Patient data were acquired according the Alzheimer's disease Neuroimaging Initiative (ADNI) protocol. Here, we implemented Fourier-wavelet regularized restoration, with a Butterworth low-pass filter, order n = 6 and a cut-off frequency f = 0.35 cycles/pixel and wavelet (Daubechies, order 2) noise suppression. The original (PET-O) and restored (PET-R) ADNI subject PET images were compared using the Alzheimer's discrimination analysis by dedicated software. Forty-two PET/CT scans were used in the study. They were performed on eleven ADNI subjects at intervals of approximately 6 months. The final clinical diagnosis was used as a gold standard. For three subjects, the final clinical diagnosis was mild cognitive impairment and those 13 PET/CT studies were not included in the final comparison, as the result was considered as inconclusive. Using the reminding 29 PET/CT studies (23 AD and 6 normal), the sensitivity and specificity of the PET-O and PET-R were calculated. The sensitivity was 0.65 and 0.96 for PET-O and PET-R, respectively, and the specificity was 0.67 and 0.50 for PET-O and PET-R. The accuracy was 0.66 and 0.86 for PET-O and PET-R, respectively. The results of the study demonstrated that the accuracy of three-dimensional brain F-18 FDG PET images was significantly improved by Fourier-wavelet restoration filtering

  2. Interest of positron emission tomography with [{sup 18}F]-fluoro-misonidazole within the frame of a dose escalation for glioblastomas; Interet de la tomographie par emission de positrons au [{sup 18}F]-fluoromisonidazole dans le cadre d'une escalade de dose pour les glioblastomes

    Energy Technology Data Exchange (ETDEWEB)

    Huchet, A.; Benech, J.; Maire, J.P.; Trouette, R.; Galland-Girodet, S. [Service de radiotherapie, CHU de Bordeaux, Bordeaux (France); Lamare, F.; Mella, C.; Clermont, H. de; Fernandez, P. [Service de medecine nucleaire, CHU de Bordeaux, Bordeaux (France); Loiseau, H. [Service de neurochirurgie, CHU de Bordeaux, Bordeaux (France)

    2011-10-15

    Eleven patients suffering from an unresectable glioblastoma have been treated by positron emission tomography (PET) with [{sup 18}F]-FMiso and submitted to a MRI before treatment. Gross target volumes (GTV) have been determined, as well as hypoxic fraction within the tumours. A complication probability calculation has been performed. It appears that the PET-[{sup 18}F]-FMiso allows a smaller volume than MRI to be defined. A Normal Tissue Complication Probability (NTCP) modelling shows that this volume limits the complication risk increase due to dose escalation. Intensity modulation allows a better taking into account of these potential benefits of this biological target volume definition. Short communication

  3. Positron emission tomography with Positome, 2

    International Nuclear Information System (INIS)

    Nukui, Hideaki; Yamamoto, Y.L.; Thompson, C.J.; Feindel, W.

    1979-01-01

    Positron emission tomography with Positome II using 68 Ga-EDTA was performed in cases with brain tumor and cerebral arteriovenous malformation. A significant focal uptake in static study and hemodynamic changes in dynamic study were noted in all cases except one case with intracranial lipoma. Comparing this method with sup(99m) Tc-pertechnetate cerebral image study and computerized axial tomography, the diagnostic rate for detecting brain tumor was almost equal in all of these three methods. However, detecting and localizing was easier and clearer in static positron emission tomography with 68 Ga-EDTA than in sup(99m) Tc-pertechnetate cerebral image and computerized axial tomography without infusion of contrast medium. Furthermore, static positron emission tomography with 68 Ga-EDTA was superior to computerized axial tomography without infusion of contrast medium for detecting cerebral arteriovenous malformation. Concerning dynamic positron emission tomography with 68 Ga-EDTA, semiquantitative values obtained by this method correlated well with findings of computerized axial tomography and was thought to be more precise and in detail than the findings of sup(99m) Tc-pertechnetate cerebral image study. Summation of the previous studies about dynamic positron emission tomography with 77 Kr in occlusive cerebrovascular disease is also reported. In conclusion, static positron emission tomography with 68 Ga-EDTA is a very useful diagnostic method for detecting and localizing brain tumor and cerebral arteriovenous malformation without any attendant complications. Furthermore, a good combination of static and dynamic positron emission tomography and computerized axial tomography appear to be outstandingly effective for not only detecting the lesion but also understanding the pathophysiological aspect in cases with various intracranial lesions. (author)

  4. Radiation-enhanced cytotoxicity of misonidazole

    International Nuclear Information System (INIS)

    Korbelik, M.; Palcic, B.; Skarsgard, L.D.

    1981-01-01

    The effect of ionizing radiation on the toxicity of misonidazole to hypoxic mammalian cells was examined. Cell toxicity response (log surviving fraction vs time of exposure to misonidazole in hypoxia) can be approximated by a biphasic curve: an initial period of approximately zero-slope shoulder, followed by exponential decrease in survival. Radiation reduced the zero-slope shoulder of toxicity response in a dose-dependent manner and at a given dose, the shoulder totally disappeared. The slope of the exponential region of the toxic response was unaffected. The same final survival level was achieved regardless of the sequence in which radiation and mixonidazole exposure were applied to cells; in fact, there was no detectable repair of that radiation-induced damage which interacts with misonidazole toxicity (up to 24 hr). A mechanism for this interaction is proposed. Clinical implications are considered assuming that similar interaction between the two modalities takes place in vivo. Since the shoulder of toxic responses is eliminated at high radiation doses, repeated administration of radiation and misonidazole could lead to additional kill of chronically and acutely hypoxic cells, if indeed both types are present in human tumors

  5. Significance of 18F-2-deoxy-2-fluoro-glucose accumulation in the stomach on positron emission tomography

    International Nuclear Information System (INIS)

    Takahashi, Hiroshi; Ukawa, Kunio; Ohkawa, Nobuhiko

    2009-01-01

    To explain the accumulation of 18 F-2-deoxy-2-fluoro-glucose ( 18 FDG) on positron emission tomography (PET) in the stomach and differences in its pattern, we focus on the accumulation pattern in association with endoscopic findings of the gastric mucosa and Helicobacter pylori (Hp) infection. Of 599 cases undergoing 18 FDG-PET examinations, we retrospectively analyzed the pattern of 18 FDG accumulation in the stomach, findings of upper gastrointestinal endoscopy, and Hp infection. The pattern of 18 FDG accumulation was classified into three groups: localized accumulation only in the fornix (Group A, 32 patients), diffuse accumulation throughout the entire stomach (Group B, 49 patients), and no accumulation (Group C, 191 patients). Regarding the relation between Hp infection and 18 FDG accumulation, Hp infection was positive in 56.3% of Group A, 73.5% of Group B, and 24.1% of Group C, with significant differences (p 18 FDG accumulation and gastric mucosal inflammation, when Groups A and B were compared with Group C, nearly half of the cases in the former groups had papular redness with a significantly higher frequency of redness and erosion. Three cases found to have malignant tumor were limited to the former groups. One mucosa-associated lymphoid tissue (MALT) lymphoma case was also found in the same group. Accumulation of 18 FDG largely corresponded to mucosal inflammation including superficial gastritis and erosive gastritis, and therefore the main cause of non-specific 18 FDG accumulation was considered to be inflammatory mucosa (mainly redness). The accumulation pattern was not associated with atrophic changes of the gastric mucosa or with Hp infection, but with mucosal inflammatory changes, including redness and erosion localized to the fornix. Accumulation of 18 FDG in the stomach suggests a high probability of the presence of inflammatory change in the gastric mucosa forming a background for the development of cancer or malignant lymphoma, and thus requires

  6. Simulation of the annihilation emission of galactic positrons; Modelisation de l'emission d'annihilation des positrons Galactiques

    Energy Technology Data Exchange (ETDEWEB)

    Gillard, W

    2008-01-15

    Positrons annihilate in the central region of our Galaxy. This has been known since the detection of a strong emission line centered on an energy of 511 keV in the direction of the Galactic center. This gamma-ray line is emitted during the annihilation of positrons with electrons from the interstellar medium. The spectrometer SPI, onboard the INTEGRAL observatory, performed spatial and spectral analyses of the positron annihilation emission. This thesis presents a study of the Galactic positron annihilation emission based on models of the different interactions undergone by positrons in the interstellar medium. The models are relied on our present knowledge of the properties of the interstellar medium in the Galactic bulge, where most of the positrons annihilate, and of the physics of positrons (production, propagation and annihilation processes). In order to obtain constraints on the positrons sources and physical characteristics of the annihilation medium, we compared the results of the models to measurements provided by the SPI spectrometer. (author)

  7. Influence of catalase on the radiation sensitizing effect of misonidazole

    International Nuclear Information System (INIS)

    Gazso, G.L.; Dam, A.

    1985-01-01

    The radiation modifying action of misonidazole and catalase was investigated in Bacillus megaterium spores at various oxygen concentrations. Catalase (120 μg/ml) decreased the radiation sensitizing action of misonidazole. Misonidazole as an electron affinic radiation sensitizer enhanced the build up of H 2 O 2 , thus promoting the reaction with catalase. Protection by catalase was not enough to eliminate the total radiation sensitizing effect of misonidazole. (orig.)

  8. Cerebral (18)FluoroDeoxy-Glucose Positron Emission Tomography in paediatric anti N-methyl-D-aspartate receptor encephalitis: A case series.

    Science.gov (United States)

    Lagarde, Stanislas; Lepine, Anne; Caietta, Emilie; Pelletier, Florence; Boucraut, José; Chabrol, Brigitte; Milh, Mathieu; Guedj, Eric

    2016-05-01

    Anti-N-methyl-D-aspartate receptor (NMDAR) encephalitis is a frequent and severe cause of encephalitis in children with potential efficient treatment (immunotherapy). Suggestive clinical features are behavioural troubles, seizures and movement disorders. Prompt diagnosis and treatment initiation are needed to guarantee favourable outcome. Nevertheless, diagnosis may be challenging because of the classical ancillary test (magnetic resonance imaging (MRI), electroencephalogram, standard cerebro-spinal fluid analysis) have limited sensitivity. Currently, immunological analyses are needed for the diagnostic confirmation. In adult patients, some studies suggested a potential role of cerebral (18)FluoroDeoxy-Glucose Positron Emission Tomography (FDG-PET) in the evaluation of anti-NMDAR encephalitis. Nevertheless, almost no data exist in paediatric population. We report retrospectively clinical, ancillary tests and cerebral FDG-PET data in 6 young patients (median age=10.5 years, 4 girls) with immunologically confirmed anti-NMDAR encephalitis. Our patients presented classical clinical features of anti-NMDAR encephalitis with severe course (notably four patients had normal MRI). Our series shows the feasibility and the good sensitivity of cerebral FDG-PET (6/6 patients with brain metabolism alteration) in paediatric population. We report some particular features in this population: extensive, symmetric cortical hypometabolism especially in posterior areas; asymmetric anterior focus of hypermetabolism; and basal ganglia hypermetabolism. We found also a good correlation between the clinical severity and the cerebral metabolism changes. Moreover, serial cerebral FDG-PET showed parallel brain metabolism and clinical improvement. Our study reveals the existence of specific patterns of brain metabolism alteration in anti-NMDAR encephalitis in paediatric population. Copyright © 2015 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  9. 2-deoxy-2[F-18]fluoro-D-mannose positron emission tomography imaging in atherosclerosis

    NARCIS (Netherlands)

    Tahara, Nobuhiro; Mukherjee, Jogeshwar; de Haas, Hans J; Petrov, Artiom D; Tawakol, Ahmed; Haider, Nezam; Tahara, Atsuko; Constantinescu, Cristian C; Zhou, Jun; Boersma, Hendrikus H; Imaizumi, Tsutomu; Nakano, Masataka; Finn, Aloke; Fayad, Zahi; Virmani, Renu; Fuster, Valentin; Bosca, Lisardo; Narula, Jagat

    Progressive inflammation in atherosclerotic plaques is associated with increasing risk of plaque rupture. Molecular imaging of activated macrophages with 2-deoxy-2[F-18]fluoro-D-glucose ([F-18]FDG) has been proposed for identification of patients at higher risk for acute vascular events. Because

  10. Distribution of adoptively transferred porcine T-lymphoblasts tracked by 18F-2-fluoro-2-deoxy-D-glucose and position emission tomography

    International Nuclear Information System (INIS)

    Eriksson, Olof; Sadeghi, Arian; Carlsson, Bjoern; Eich, Torsten; Lundgren, Torbjoern; Nilsson, Bo; Toetterman, Thomas; Korsgren, Olle; Sundin, Anders

    2011-01-01

    Introduction: Autologous or allogeneic transfer of tumor-infiltrating T-lymphocytes is a promising treatment for metastatic cancers, but a major concern is the difficulty in evaluating cell trafficking and distribution in adoptive cell therapy. This study presents a method of tracking transfusion of T-lymphoblasts in a porcine model by 18 F-2-fluoro-2-deoxy-D-glucose ([ 18 F]FDG) and positron emission tomography. Methods: T-lymphoblasts were labeled with the positron-emitting tracer [ 18 F]FDG through incubation. The T-lymphoblasts were administered into the bloodstream, and the distribution was followed by positron emission tomography for 120 min. The cells were administered either intravenously into the internal jugular vein (n=5) or intraarterially into the ascending aorta (n=1). Two of the pigs given intravenous administration were pretreated with low-molecular-weight dextran sulphate. Results: The cellular kinetics and distribution were readily quantifiable for up to 120 min. High (78.6% of the administered cells) heterogeneous pulmonary uptake was found after completed intravenous transfusion. The pulmonary uptake was decreased either by preincubating and coadministrating the T-lymphoblasts with low-molecular-weight dextran sulphate or by administrating them intraarterially. Conclusions: The present work shows the feasibility of quantitatively monitoring and evaluating cell trafficking and distribution following administration of [ 18 F]FDG-labeled T-lymphoblasts. The protocol can potentially be transferred to the clinical setting with few modifications.

  11. Positron emission tomography in epilepsy

    International Nuclear Information System (INIS)

    Hosokawa, Shinichi; Kato, Motohiro; Otsuka, Makoto; Kuwabara, Yasuo; Ichiya, Yuichi; Goto, Ikuo

    1989-01-01

    Positron emission tomography (PET) was performed with the 18 F-fluoro-deoxy-glucose method on 29 patients with epilepsy (generalized epilepsy, 4; partial epilepsy, 24; undetermined type, 1). The subjects were restricted to patients with epilepsy without focal abnormality on X-CT. All the patients with generalized epilepsy showed a normal pattern on PET. Fourteen out of the 24 patients with partial epilepsy and the 1 with epilepsy of undermined type showed focal hypometabolism on PET. The hypometabolic zone was localized in areas including the temporal cortex in 11 patients, frontal in 2 and thalamus in 1. The location of hypometabolic zone and that of interictal paroxysmal activity on EEG were well correlated in most patients. The patients with poorly-controlled seizure showed a higher incidence of PET abnormality (12 out of 13) than those with well-controlled seizures (2 out of 11). The incidence of abnormality on PET and MRI and the location of both abnormality were not necessarily coincident. These results indicated that the PET examination in epilepsy provides valuable information about the location of epileptic focus, and that the findings on PET in patients with partial epilepsy may be one of the good indicators about the intractability of partial epilepsy, and that PET and MRI provide complementary information in the diagnosis of epilepsy. (author)

  12. New Possibilities of Positron-Emission Tomography

    Science.gov (United States)

    Volobuev, A. N.

    2018-01-01

    The reasons for the emergence of the angular distribution of photons generated as a result of annihilation of an electron and a positron in a positron-emission tomograph are investigated. It is shown that the angular distribution of the radiation intensity (i.e., the probability of photon emission at different angles) is a consequence of the Doppler effect in the center-of-mass reference system of the electron and the positron. In the reference frame attached to the electron, the angular distribution of the number of emitted photons does not exists but is replaced by the Doppler shift of the frequency of photons. The results obtained in this study make it possible to extend the potentialities of the positron-emission tomograph in the diagnostics of diseases and to obtain additional mechanical characteristics of human tissues, such as density and viscosity.

  13. Instrumentation for positron emission tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.; Derenzo, S.E.; Huesman, R.H.

    1984-01-01

    Positron emission tomography with a spatial resolution of 2 mm full width at half maximum for quantitation in regions of interest 4 mm in diameter will become possible with the development of detectors that achieve ultrahigh resolution. Improved resolution will be possible using solid-state photodetectors for crystal identification or photomultiplier tubes with many small electron multipliers. Temporal resolution of 2 seconds and gating of cyclic events can be accomplished if statistical requirements are met. The major physical considerations in achieving high-resolution positron emission tomography are the degradation in resolution resulting from positron range, emission angle, parallax error, detector sampling density, the sensitivity of various detector materials and packing schemes, and the tradeoff between temporal resolution and statistical accuracy. The accuracy of data required for physiological models depends primarily on the fidelity of spatial sampling independent of statistical constraints

  14. Positron emission tomography. Basic principles

    International Nuclear Information System (INIS)

    Rodriguez, Jose Luis; Massardo, Teresa; Gonzalez, Patricio

    2001-01-01

    The basic principles of positron emission tomography (PET) technique are reviewed. lt allows to obtain functional images from gamma rays produced by annihilation of a positron, a positive beta particle. This paper analyzes positron emitters production in a cyclotron, its general mechanisms, and the various detection systems. The most important clinical applications are also mentioned, related to oncological uses of fluor-l8-deoxyglucose

  15. Tumour and lymph node uptakes on dual-phased 2-deoxy-2-[18F]fluoro-D-glucose positron emission tomography/computed tomography correlate with prognostic parameters in breast cancer.

    Science.gov (United States)

    Chang, Chin-Chuan; Tu, Hung-Pin; Chen, Yu-Wen; Lin, Chia-Yang; Hou, Ming-Feng

    2014-12-01

    To examine correlations between the uptake of 2-deoxy-2-[18F]fluoro-D-glucose (FDG) by primary tumours and axillary lymph nodes, and clinical and biological tumour prognostic parameters, in patients with newly diagnosed breast cancer. Newly diagnosed breast cancer patients who had received a dual-phased FDG positron emission tomography/computed tomography scan for pretreatment staging were enrolled retrospectively. Maximal standardized uptake values at 1 h (SUV1), 2 h (SUV2), and retention indices (RI) of the tumours and ipsilateral axillary lymph nodes were measured. SUV and RI were compared with clinical and biological prognostic parameters. A total of 32 patients participated in the study. Tumour FDG uptake correlated with histological grade and tumour size. FDG uptake in axillary lymph nodes correlated positively with lymph node status, metastasis status and clinical stage. RI values for the tumour and lymph nodes were significantly positively correlated with human epidermal growth factor receptor-2 positivity. FDG uptake in tumours and lymph nodes showed correlations with some clinical and biological parameters, and may serve as a predictive marker of tumour biological behaviour in breast cancer. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  16. Simulation of the annihilation emission of galactic positrons

    International Nuclear Information System (INIS)

    Gillard, W.

    2008-01-01

    Positrons annihilate in the central region of our Galaxy. This has been known since the detection of a strong emission line centered on an energy of 511 keV in the direction of the Galactic center. This gamma-ray line is emitted during the annihilation of positrons with electrons from the interstellar medium. The spectrometer SPI, onboard the INTEGRAL observatory, performed spatial and spectral analyses of the positron annihilation emission. This thesis presents a study of the Galactic positron annihilation emission based on models of the different interactions undergone by positrons in the interstellar medium. The models are relied on our present knowledge of the properties of the interstellar medium in the Galactic bulge, where most of the positrons annihilate, and of the physics of positrons (production, propagation and annihilation processes). In order to obtain constraints on the positrons sources and physical characteristics of the annihilation medium, we compared the results of the models to measurements provided by the SPI spectrometer. (author)

  17. Positron emission tomography now and in the future

    International Nuclear Information System (INIS)

    Vaalburg, W.

    1987-01-01

    A survey is given of positron emission tomography used in nuclear medicine. The production of positron emitting radionuclides is discussed. The development of positron detectors is described. The application of positron emission tomography in cardiology, oncology and neurology is treated. The authors conclude that PET is a unique method to examine metabolic processes, although the method is still in its infancy. 7 refs.; 1 table

  18. Positron emission computed tomography

    International Nuclear Information System (INIS)

    Grover, M.; Schelbert, H.R.

    1985-01-01

    Regional mycardial blood flow and substrate metabolism can be non-invasively evaluated and quantified with positron emission computed tomography (Positron-CT). Tracers of exogenous glucose utilization and fatty acid metabolism are available and have been extensively tested. Specific tracer kinetic models have been developed or are being tested so that glucose and fatty acid metabolism can be measured quantitatively by Positron-CT. Tracers of amino acid and oxygen metabolism are utilized in Positron-CT studies of the brain and development of such tracers for cardiac studies are in progress. Methods to quantify regional myocardial blood flow are also being developed. Previous studies have demonstrated the ability of Positron-/CT to document myocardial infarction. Experimental and clinical studies have begun to identify metabolic markers of reversibly ischemic myocardium. The potential of Positron-CT to reliably detect potentially salvageable myocardium and, hence, to identify appropriate therapeutic interventions is one of the most exciting applications of the technique

  19. Positron emission tomography of the heart

    International Nuclear Information System (INIS)

    Budinger, T.F.; Yano, Y.; Mathis, C.A.; Moyer, B.R.; Huesman, R.H.; Derenzo, S.E.

    1983-01-01

    Positron emission tomography (PET) offers the opportunity to noninvasively measure heart muscle blood perfusion, oxygen utilization, metabolism of fatty acids, sugars and amino acids. This paper reviews physiological principles which are basic to PET instrumentation for imaging the heart and gives examples of the application of positron emission tomography for measuring myocardial flow and metabolism. 33 references, 11 figures, 1 table

  20. Positron emission tomography-computed tomography protocol considerations for head and neck cancer imaging.

    Science.gov (United States)

    Escott, Edward J

    2008-08-01

    Positron emission tomographic-computed tomographic (PET-CT) imaging of patients with primary head and neck cancers has become an established approach for staging and restaging, as well as radiation therapy planning. The inherent co-registration of PET and CT images made possible by the integrated PET-CT scanner is particularly valuable in head and neck cancer imaging due to the complex and closely situated anatomy in this part of the body, the varied sources of physiologic and benign 2-deoxy-2-[F-18]fluoro-D-glucose (FDG) tracer uptake that occurs in the neck, and the varied and complex posttreatment appearance of the neck. Careful optimization of both the CT and the PET portion of the examination is essential to insure the most accurate and clinically valuable interpretation of these examinations.

  1. The relation of putamen nucleus 6-[18F]fluoro-L-m-tyrosine uptake to total Unified Parkinson's Disease Rating Scale scores

    International Nuclear Information System (INIS)

    Buchy, R.

    2002-01-01

    The contribution of dopaminergic deficiency in the striatum to the severity of locomotor disability in Parkinson's disease has been consistently shown with 6-[ 18 F]fluoro-L-DOPA in positron emission tomography. Recently, 6-[ 18 F]fluoro-L-m-tyrosine, an alternative tracer with similar distribution kinetics has been used to facilitate data analysis. Locomotor disability in Parkinson's disease can be measured using the Unified Parkinson's Disease Rating Scale. The Unified Parkinson's Disease Rating Scale was used in conjunction with 6-[ 18 F]fluoro-L-m-tyrosine -PET to clinically examine a group of five Parkinson's disease patients. An inverse relation similar to that previously demonstrated with 6-[ 18 F]fluoro-L-DOPA was found between the putamen nucleus 6-[ 18 F]fluoro-L-m-tyrosine influx constant and Unified Parkinson's Disease Rating Scale score. This finding suggests that like 6-[ 18 F]fluoro-L-m-tyrosine can be used to accurately measure the degree of locomotor disability caused by Parkinson's disease. (author)

  2. Enhancement of misonidazole radiosensitization by an inhibitor of glutathione biosynthesis

    International Nuclear Information System (INIS)

    Hodgkiss, R.J.; Middleton, R.W.

    1983-01-01

    A well known inhibitor of glutathione biosynthesis, buthione sulphoximine (S-n-butyl homocysteine sulphoximine, BSO) depletes non-protein sulphydryls (NPSH) in Chinese hamster cells in vitro, resulting in a marked increase in the radiosensitization efficiency of misonidazole. V79 379A Chinese hamster cells were maintained in suspension cultures and irradiated in monolayers using 250 kVp X-rays at a dose rate of 3.93 Gy/min. Radiosensitization by misonidazole alone gave results within 0.1 sensitizer enhancement ratio (s.e.r.) of the curve reported by Watts et al. (1980). GSH (2 mmol dm - 3 ) added to the extracellular medium resulted in a marked decrease in the radiosensitization efficiency of misonidazole, eliminating the effect at 0.1 mmol dm - 3 misonidazole (s.e.r. = 1.0 relative to nitrogen control). A marked enhancement of the radiosensitization by misonidazole was observed when the cells had been incubated with BSO (0.1 mmol dm - 3 ). BSO alone at this concentration gave s.e.r. = 1.17; misonidazole alone (0.1 mmol dm - 3 ) gave s.e.r. = 1.18 and misonidazole with BSO (both 0.1. mmol dm - 3 ) gave s.e.r. = 1.9. The BSO treatment gave little effect in aerated cells. The concentration of BSO needed to produce these effects in vitro is ca. 40-fold lower than doses tolerated by mice in repeated administrations. (U.K.)

  3. Tomography by positrons emission

    International Nuclear Information System (INIS)

    Mosconi, Sergio L.

    1999-01-01

    The tomography by positrons emission is a technology that allows to measure the concentration of positrons emission in a tri dimensional body through external measurements. Among the isotope emissions have carbon isotopes are ( 11 C), of the oxygen ( 15 O), of the nitrogen ( 13 N) that are three the element that constitute the base of the organic chemistry. Theses have on of the PET's most important advantages, since many biological interesting organic molecules can be tracer with these isotopes for the metabolism studies 'in vivo' through PET, without using organic tracers that modify the metabolism. The mentioned isotopes, also possess the characteristic of having short lifetime, that constitute on of PET's advantages from the dosimetric point of view. Among 11 C, 15 O, and 13 N, other isotopes that can be obtained of a generator as the 68 Ga and 82 Rb

  4. Manipulation of [C-11]-5-hydroxytryptophan and 6-[F-18]fluoro-3,4-dihydroxy-L-phenylalanine accumulation in neuroendocrine tumor cells

    NARCIS (Netherlands)

    Neels, Oliver C.; Koopmans, Klaas P.; Jager, Pieter L.; Vercauteren, Laya; van Waarde, Aren; Doorduin, Janine; Timmer-Bosscha, Hetty; Brouwers, Adrienne H.; de Vries, Elisabeth G. E.; Dierckx, Rudi A. J. O.; Kema, Ido P.; Elsinga, Philip H.

    2008-01-01

    [C-11]-5-Hydroxytryptophan ([C-11]HTP) and 6-[F-18]fluoro-3,4-dihydroxy-L-phenylalanine [F-18]FDOPA) are used to image neuroendocrine tumors with positron emission tomography. The precise mechanism by which these tracers accumulate in tumor cells is unknown. We aimed to study tracer uptake via large

  5. Effect of misonidazole on radiosensitivity of Ehrlich ascites tumor cells

    International Nuclear Information System (INIS)

    Takeuchi, Hiroshi

    1986-01-01

    The effect of Misonidazole on radiosensitivity of Ehrlich ascites tumor cells was studied in vivo. Ehrlich ascites tumor cells growing intraperitoneally (ICR/SIC mice) for either 1, 4, 6 or 10 days were irradiated in vivo (whole body irradiation) with or without Misonidazole. Immediately after irradiation tumor cells were transplanted intraperitoneally into new animals. Four days later, the propagated surviving cells were removed and counted for analyses. Enhancement ratio of Misonidazole at the surviving fraction of 0.1 were 1.0 (for 1-day-old), 1.3 (for 4-day-old), 1.9 (for 6-day-old), 1.9 (for 10-day-old) and 2.8 (for anoxic cells) respectively. The gradual increase of the enhancement ratio of the ascites tumore cells during intraperitoneal growth from 1 through 10 days might be attributed to an increase of hypoxic tumor cells. Cytotoxicity was not observed at 0.1 mg per gram body weight of Misonidazole but was at 1 mg per gram body weight of Misonidazole in 6-day-old and 10-day-old Ehrlich ascites tumor cells which were supposed to contain hypoxic cells. These results suggest that Misonidazole may prove an effective radiosensitizer for hypoxic tumor cells. (author)

  6. Kinetic aspects of misonidazole and its major metabolite in radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Meering, P.G.; Maes, R.A.A. (Rijksuniversiteit Utrecht (Netherlands). Centre for Human Toxicology); Gonzalez, D.G. (Amsterdam Univ. (Netherlands). Dept. of Radiotherapy); Peperzeel, H.A. van (Rijksuniversiteit Utrecht (Netherlands). Academisch Ziekenhuis)

    1985-01-01

    Oral doses of misonidazole between 0.75 and 1.3 g/m/sup 2/ were administered during 3-5 days per week to 21 patients with various malignancies. Mean plasma levels of misonidazole and desmethylmisonidazole at the times of radiotherapy were in the range 20-50 and 2-12 mg/1 respectively. Slight accumulation of misonidazole and desmethylmisonidazole in plasma was observed with a dosage interval of 24 h. In patients with anticonvulsant comedication plasma elimination half-lives of misonidazole of 4.1-8.9 h were found. Observed side-effects were nausea and vomiting (9%), exanthema or rashes (14%) and mild peripheral neuropathy (9%).

  7. Positron emission tomography in neuropsychology.

    Science.gov (United States)

    Heiss, W D; Herholz, K; Pawlik, G; Wagner, R; Wienhard, K

    1986-01-01

    By positron emission tomography (PET) of 18F-2-fluoro-2-deoxy-D-glucose (FDG) local cerebral metabolic rate for glucose (LCMRGl) can be measured in man. Normal values in cerebral cortex and basal ganglia range from 35 to 50 mumol/100 g/min, the values in gray matter structures of the posterior fossa were 25-30 mumol/100 g/min, the lowest LCMRGl was found in the white matter (15-20 mumol/100 g/min). During sensory stimulation by various modalities functional activation increases LCMRGl in the respective special areas, while sleep decreases metabolic rate in all cortical and basal gray matter structures. In many neurological disorders CMRGl is altered in a disease-specific pattern. In dementia of the Alzheimer type CMRGl is impaired even in early stages with accentuation in the parieto-temporal cortex, while in multi-infarct dementia glucose uptake is mainly reduced in the multifocal small infarcts. In Huntington's chorea the most conspicuous changes are found in the caudate nucleus and putamen. In cases of focal lesions (e.g. ischemic infarcts) metabolic disturbances extend far beyond the site of the primary lesion and inactivation of metabolism is found in intact brain structures far away from the anatomical lesion. Additional applications of PET include determination of the metabolism of various substrates, of protein synthesis, of function and distribution of receptors, of tumor growth and of the distribution of drugs as well as the measurement of oxygen consumption, blood flow and blood volume.

  8. NMF on positron emission tomography

    DEFF Research Database (Denmark)

    Bödvarsson, Bjarni; Hansen, Lars Kai; Svarer, Claus

    2007-01-01

    In positron emission tomography, kinetic modelling of brain tracer uptake, metabolism or binding requires knowledge of the cerebral input function. Traditionally, this is achieved with arterial blood sampling in the arm or as shown in (Liptrot, M, et al., 2004) by non-invasive K-means clustering....... We propose another method to estimate time-activity curves (TAC) extracted directly from dynamic positron emission tomography (PET) scans by non-negative matrix factorization (NMF). Since the scaling of the basis curves is lost in the NMF the estimated TAC is scaled by a vector alpha which...

  9. Positron emission tomography in oncology

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    This report describes the current and potential uses of positron emission tomography in clinical medicine and research related to oncology. Assessment will be possible of metabolism and physiology of tumors and their effects on adjacent tissues. Specific probes are likely to be developed for target sites on tumors, including monoclonal antibodies and specific growth factors that recognize tumors. To date, most oncological applications of positron emission tomography tracers have been qualitative; in the future, quantitative metabolic measurements should aid in the evaluation of tumor biology and response to treatment

  10. 6-[18F]fluoro-A-85380: an in vivo tracer for the nicotinic acetylcholine receptor

    International Nuclear Information System (INIS)

    Scheffel, Ursula; Horti, Andrew G.; Koren, Andrei O.; Ravert, Hayden T.; Banta, Jeffrey P.; Finley, Paige A.; London, Edythe D.; Dannals, Robert F.

    2000-01-01

    6-[ 18 F]Fluoro-3-(2(S)-azetidinylmethoxy)pyridine (6-[ 18 F]fluoro-A-85380 or 6-[ 18 F]FA), a new tracer for positron emission tomography, was synthesized by no-carrier-added [ 18 F] fluorination of 6-iodo-3-((1-tert-butoxycarbonyl-2(S)-azetidinyl)methoxy)pyridine followed by acidic deprotection. 6-[ 18 F]FA followed the regional densities of brain nicotinic acetylcholine receptors (nAChRs) reported in the literature. Evidence of binding to nAChRs and high specificity of the binding in vivo was demonstrated by inhibition with nAChR selective ligands as well as with unlabeled 6-FA. A preliminary toxicology study of the 6-FA showed a relatively low biological effect

  11. Positron emission tomography

    International Nuclear Information System (INIS)

    Bolwig, T.G.; Haunsoe, S.; Dahlgaard Hove, J.; Hesse, B.; Hoejgard, L.; Jensen, M.; Paulson, O.B.; Hastrup Svendsen, J.; Soelvsten Soerensen, S.

    1994-01-01

    Positron emission tomography (PET) is a method for quantitative imaging of regional physiological and biochemical parameters. Positron emitting radioactive isotopes can be produced by a cyclotron, eg. the biologically important carbon ( 11 C), oxygen ( 15 O), and nitrogen ( 13 N) elements. With the tomographic principles of the PET scanner the quantitative distribution of the administered isotopes can be determined and images can be provided as well as dynamic information on blood flow, metabolism and receptor function. In neurology PET has been used for investigations on numerous physiological processes in the brain: circulation, metabolism and receptor studies. In Parkinson's disease PET studies have been able to localize the pathology specifically, and in early stroke PET technique can outline focal areas with living but non-functioning cells, and this could make it possible to intervene in this early state. With positron emission tomography a quantitative evaluation of myocardial blood flow, glucose and fatty acid metabolism can be made as well as combined assessments of blood flow and metabolism. Combined studies of blood flow and metabolism can determine whether myocardial segments with abnormal motility consist of necrotic or viable tissue, thereby delineating effects of revascularisation. In the future it will probably be possible to characterize the myocardial receptor status in different cardiac diseases. The PET technique is used in oncology for clinical as well as more basic research on tumor perfusion and metabolism. Further, tumor uptake of positron labelled cytotoxic drugs might predict the clinical benefit of treatment. (au) (19 refs.)

  12. F-18-fluorodeoxyglucose-positron emission tomography in colorectal cancer

    International Nuclear Information System (INIS)

    Joerg, L.; Langsteger, W.

    2002-01-01

    Whole-body positron emission tomography (PET) with the radiolabeled glucose analog F-18-fluorodeoxyglucose (F-18-FDG) is a sensitive diagnostic tool that images tumors based on increased uptake of glucose. Several recent publications have shown that F-18-fluorodeoxyglucose-positron emission tomography is more sensitive than computed-tomography (CT) in detecting colorectal cancer. In patients with increasing CEA (carcinoembryonic antigen) and no evidence of recurrent disease on CT F-18-fluorodeoxyglucose-positron emission tomography often detects recurrent cancer. In all, patient management seems to be changed in about 25 % of patients who undergo F-18-fluorodeoxyglucose-positron emission tomography in addition to standard staging procedure. Limited reports to date on both chemotherapy and radiotherapy support the role of F-18-fluorodeoxyglucose-positron emission tomography in assessing treatment response. Also regarding preoperative staging of primary colorectal cancer the literature is very limited. (author)

  13. Fluorinated tracers for imaging cancer with positron emission tomography

    International Nuclear Information System (INIS)

    Couturier, Olivier; Chatal, Jean-Francois; Luxen, Andre; Vuillez, Jean-Philippe; Rigo, Pierre; Hustinx, Roland

    2004-01-01

    2-[ 18 F]fluoro-2-deoxy-d-glucose (FDG) is currently the only fluorinated tracer used in routine clinical positron emission tomography (PET). Fluorine-18 is considered the ideal radioisotope for PET imaging owing to the low positron energy (0.64 MeV), which not only limits the dose rate to the patient but also results in a relatively short range of emission in tissue, thereby providing high-resolution images. Further, the 110-min physical half-life allows for high-yield radiosynthesis, transport from the production site to the imaging site and imaging protocols that may span hours, which permits dynamic studies and assessment of potentially fairly slow metabolic processes. The synthesis of fluorinated tracers as an alternative to FDG was initially tested using nucleophilic fluorination of the molecule, as performed when radiolabelling with iodine-124 or bromide-76. However, in addition to being long, with multiple steps, this procedure is not recommended for bioactive molecules containing reactive groups such as amine or thiol groups. Radiochemical yields are also often low. More recently, radiosynthesis from prosthetic group precursors, which allows easier radiolabelling of biomolecules, has led to the development of numerous fluorinated tracers. Given the wide availability of 18 F, such tracers may well develop into important routine tracers. This article is a review of the literature concerning fluorinated radiotracers recently developed and under investigation for possible PET imaging in cancer patients. Two groups can be distinguished. The first includes ''generalist'' tracers, i.e. tracers amenable to use in a wide variety of tumours and indications, very similar in this respect to FDG. These are tracers for non-specific cell metabolism, such as protein synthesis, amino acid transport, nucleic acid synthesis or membrane component synthesis. The second group consists of ''specific'' tracers for receptor expression (i.e. oestrogens or somatostatin), cell

  14. Positron emission tomography - a new approach to brain chemistry

    International Nuclear Information System (INIS)

    Jacobson, H.G.

    1988-01-01

    Positron emission tomography permits examination of the chemistry of the brain in living beings. Until recently, positron emission tomography had been considered a research tool, but it is rapidly moving into clinical practice. This report describes the uses and applications of positron emission tomography in examinations of patients with strokes, epilepsy, malignancies, dementias, and schizophrenia and in basic studies of synaptic neurotransmission

  15. Detection of a reactive metabolite of misonidazole in human urine

    International Nuclear Information System (INIS)

    Varghese, A.J.; Whitmore, G.F.

    1984-01-01

    Chemical studies have indicated that, following reduction of misonidazole to the hydroxylamine derivative, reaction with guanosine leads to the formation of a 2-carbon addition product of guanosine. In this study, the formation of the guanosine product is used to detect the presence of a reactive metabolite of misonidazole in the urine of patients treated with misonidazole. Urine samples were incubated with [ 14 C]guanosine and the guanosine product was separated by HPLC analysis. The quantities of product vary as much as 10-fold from patient to patient and it is suggested that the assay be useful as a predictor of patients susceptible to the development of peripheral neuropathy or other effects of misonidazole

  16. Assessment of infarct size by positron emission tomography and [18F]2-fluoro-2-deoxy-D-glucose: a new absolute threshold technique

    International Nuclear Information System (INIS)

    Chareonthaitawee, P.; Iozzo, Patricia; Schaefers, K.; Stegger, L.; Baker, C.S.R.; Camici, Paolo G.; Rimoldi, Ornella; Turkheimer, F.; Banner, N.R.; Yacoub, Magdi; Bonser, Robert S.

    2002-01-01

    Along with hibernating myocardium, infarct size is a critical term in the progression of left ventricular remodelling and congestive heart failure. Both infarcted and hibernating myocardium determine changes in remote non-ischaemic tissue. This study was designed to test the accuracy of a new technique to quantify infarct size using positron emission tomography (PET) with [ 18 F]2-fluoro-2-deoxy-D-glucose (FDG). Studies were carried out in (a) nine pigs with acute myocardial infarction (two sham-operated), produced by a 90-min occlusion of the circumflex coronary artery followed by a 4-h reperfusion, and (b) humans (six patients with ischaemic cardiomyopathy awaiting cardiac transplantation and five normal volunteers). In both animals and patients, myocardial FDG uptake was measured by PET during hyperinsulinaemic-euglycaemic clamp. Infarct size was quantified by an absolute threshold of tracer uptake obtained from the parametric (voxel-by-voxel) image of the metabolic rate of FDG. PET infarct size estimates were compared with independent ex vivo planimetric measurements of the explanted swine and patient hearts (at transplantation) after staining with triphenyltetrazolium chloride. There was good agreement between the planimetric and PET infarct size estimates both in pigs (n=9; r=0.96, y=0.94x +0.64, SEE=0.10, P<0.0001) and in humans (n=11; r=0.94, y=0.72x +2.93, SEE=0.09, P<0.0001). This study demonstrates the feasibility and accuracy of this PET method in estimating infarct size both in a model of reperfused acute myocardial infarction and in chronic ischaemic cardiomyopathy, although larger studies are needed to confirm these findings. (orig.)

  17. Detectability of colorectal neoplasia with fluorine-18-2-fluoro-2-deoxy-D-glucose positron emission tomography and computed tomography (FDG-PET/CT)

    International Nuclear Information System (INIS)

    Hirakawa, Tomoko; Okumura, Yoshihiro; Kato, Jun

    2012-01-01

    The purpose of this study was to analyze the detectability of colorectal neoplasia with fluorine-18-2-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (FDG-PET/CT). Data for a total of 492 patients who had undergone both PET/CT and colonoscopy were analyzed. After the findings of PET/CT and colonoscopy were determined independently, the results were compared in each of the six colonic sites examined in all patients. The efficacy of PET/CT was determined using colonoscopic examination as the gold standard. In all, 270 colorectal lesions 5 mm or more in size, including 70 pathologically confirmed malignant lesions, were found in 172 patients by colonoscopy. The sensitivity and specificity of PET/CT for detecting any of the colorectal lesions were 36 and 98%, respectively. For detecting lesions 11 mm or larger, the sensitivity was increased to 85%, with the specificity remaining consistent (97%). Moreover, the sensitivity for tumors 21 mm or larger was 96% (48/50). Tumors with malignant or high-grade pathology were likely to be positive with PET/CT. A size of 10 mm or smaller [odds ratio (OR) 44.14, 95% confidence interval (95% CI) 11.44-221.67] and flat morphology (OR 7.78, 95% CI 1.79-36.25) were significant factors that were associated with false-negative cases on PET/CT. The sensitivity of PET/CT for detecting colorectal lesions is acceptable, showing size- and pathology-dependence, suggesting, for the most part, that clinically relevant lesions are detectable with PET/CT. However, when considering PET/CT for screening purposes caution must be exercised because there are cases of false-negative results. (author)

  18. Comparison of (68)Ga-DOTA-Tyr(3)-octreotide and (18)F-fluoro-L-dihydroxyphenylalanine positron emission tomography in neuroendocrine tumor patients.

    Science.gov (United States)

    Putzer, D; Gabriel, M; Kendler, D; Henninger, B; Knoflach, M; Kroiss, A; Vonguggenberg, E; Warwitz, B; Virgolini, I J

    2010-02-01

    (68)Ga-DOTA-Tyr3-octreotide positron emission tomography ((68)Ga-DOTA-TOC PET) and (18)F-fluoro-L-dihydroxyphenylalanine PET ((18)F-DOPA PET) are emerging modalities for imaging of neuroendocrine tumors. This study reports our initial experiences with these two PET modalities on initial diagnosis, staging and restaging in NET patients. Fifteen patients with NET underwent both (68)Ga-DOTA-TOC and (18)F-DOPA PET as well as computed tomography (CT). Image findings were compared on a patient-basis (pathological uptake: yes/no) as well as on a lesion-basis. Contrast-enhanced CT and histological follow-up served as gold standard. Furthermore, imaging results were matched with tumor marker levels and quantitative tracer uptake by the tumor lesions. When comparing (68)Ga-DOTA-TOC and (18)F-DOPA PET, each modality showed a sensitivity of 64% and a specificity of 100% on a patient-based analysis. (68)Ga-DOTA-TOC PET and (18)F-DOPA PET showed equal findings in 7 out of 15 patients and disagreement in 8 patients. (68)Ga-DOTA-TOC revealed more metastases than (18)F-DOPA PET in 6 patients, while (18)F-DOPA PET detected more metastases than (68)Ga-DOTA-TOC in 4 patients. By (68)Ga-DOTA-TOC PET, 208 malignant lesions were detected, while by (18)F-DOPA only 86 lesions were found, and in CT 124, respectively. (68)Ga-DOTA-TOC and (18)F-DOPA PET are useful tools in the detection and staging of NET lesions. Our initial results allow the conclusion that (68)Ga-DOTA-TOC PET may have a stronger clinical impact in NET patients, as it does not only offer diagnostic information, but is decisive for the further treatment management, i. e. PRRT, as well.

  19. Positron-molecule interactions and corresponding positron attachment to molecules. As a basis for positron emission tomography (PET)

    International Nuclear Information System (INIS)

    Tachikawa, Masanori; Kimura, Mineo; Pichl, Lukas

    2007-01-01

    Through positron and electron interactions, they annihilate emitting primarily two gamma rays with 180-degree opposite directions. Positron spectroscopy using the characteristics of these gamma rays has been employed for analyzing various properties of material as well as for positron emission tomography (PET). However, its fundamental physics of positron-electron interactions and resulting features of emitting gamma rays are not well understood. By obtaining better understanding of positron interactions, it should become possible to provide the firm bases for positron spectroscopy in finer accuracy and quality. Here, we propose a significant mechanism for positron annihilation through positron attachment process, which may help increase the quality of positron spectroscopy. (author)

  20. Basic concepts on positron emission tomography in oncology and pediatric peculiarities

    International Nuclear Information System (INIS)

    Giammarile, F.; Pellet, O.

    2002-01-01

    (Positron Emission Tomography (PET) is an old functional imaging method, pertaining to the nuclear medicine field, based on the utilisation of positrons emitting nuclei, fixed on targeted molecules. Available since the Seventies, the clinical impact of PET grows daily, particularly in oncology. This method rests on the coincidence detection of the photons issued by the annihilation of the positron. It can be carried out on dedicated scans, equipped with a crown of detectors (PET camera) or on classical cameras whose crystal and electronic system has been adapted CDET camera). The 2-deoxy-2 fluoro-D-glucose marked with fluorine 18 [18FDG or FDG is a glucose analogue. Its cellular uptake uses the facilitated transport of glucose but its metabolism is partial because, contrary to this one, it remains within the cell. This allows functional studies (evaluation of glucose metabolism) on the cell. FDG uptake is thus increased under the pathological conditions comprising an increase in the consumption of glucose either by increase in glycolysis (malignant tumoral tissue) or by increase in the only anaerobic cycle (ischaemia). Consequently, this diagnostic method identifies in vivo the hyper-metabolism of malignant cells and provides a quantification of the tumoral glycolysis, during and after treatment. In Paediatrics, its diffusion and its use in clinical routine, are currently limited, because of the limited availability of the equipment. It is probable that with the awaited rise of PET in France, the paediatric applications will also see their place increasing in the diagnostic strategy of cancer. (authors)

  1. Positron emission tomography in the management of cervix cancer patients; Tomographie par emission de positons dans la prise en charge des cancers du col de l'uterus

    Energy Technology Data Exchange (ETDEWEB)

    Bonardel, G.; Gontier, E.; Soret, M.; Dechaud, C.; Fayolle, M.; Foehrenbach, H. [Hopital d' Instruction des Armees du Val-de-Grace, Service de Medecine Nucleaire, 75 - Paris (France); Chargari, C.; Bauduceau, O. [Hopital d' Instruction des Armees du Val-de-Grace, Service de Radiotherapie, 75 - Paris (France)

    2009-10-15

    Since its introduction in clinical practice in the 1990 s, positron emission tomography (PET), usually with {sup 18}F-fluoro-2-deoxy-D-glucose ({sup 18}F-F.D.G.), has become an important imaging modality in patients with cancer. For cervix carcinoma, F.D.G.-PET is significantly more accurate than computed tomography (CT) and is recommended for loco-regional lymph node and extra pelvic staging. The metabolic dimension of the technique provides additional prognostic information. Ongoing studies now concentrate on more advanced clinical applications, such as the planning of radiotherapy, the response evaluation after the induction of therapy, the early detection of recurrence. Technical innovations, such as PET cameras with better spatial resolution and hybrid positron emission tomography/computed tomography (PET-CT), available now on the whole territory, provide both anatomic and metabolic information in the same procedure. From the point of view of biological metabolism, new radiopharmaceutical probes are being developed. Those hold promise for future refinements in this field. This article reviews the current applications of F.D.G.-PET in patients with cervix cancer. (authors)

  2. A prospective evaluation of the impact of 18-F-fluoro-deoxy-D-glucose positron emission tomography staging on survival for patients with locally advanced esophageal cancer

    International Nuclear Information System (INIS)

    Blackstock, A. William; Farmer, Michael R.; Lovato, James; Mishra, Girish; Melin, Susan A.; Oaks, Timothy; Aklilu, Mabea; Clark, Paige B.; Levine, Edward A.

    2006-01-01

    Purpose: To determine the impact of 18-F-fluoro-deoxy-D-glucose positron emission tomography (FDG-PET) in the staging and prognosis of patients with locally advanced esophageal cancer (LAEC). Methods and Materials: Between January 2000 and October 2004, all patients with LAEC evaluated in the Department of Radiation Oncology were considered for enrollment into a Phase II trial of preoperative chemoradiation. Entry required a staging whole-body FDG-PET scan. Results: One hundred ten consecutive patients were evaluated; 38 were ineligible for reasons including treatment elsewhere, prior malignancy, or refusal of treatment. After conventional staging (clinical examination, endoscopic ultrasound, and chest/abdominal computerized tomography), 33 patients were ineligible because of metastatic disease or poor performance status. Of the remaining 39 patients, 23 were confirmed to have LAEC after FDG-PET staging and were treated in the Phase II trial (Cohort I). Sixteen patients, however, had FDG-PET findings consistent with occult metastatic disease and were deemed ineligible for the trial but were treated with curative intent (Cohort II). The 2-year survival rate for the 23 patients in Cohort I was 64%, compared with 17% (p = 0.003) for patients in Cohort II (FDG-PET positive). Conclusions: More than one-third of patients determined to have LAEC with conventional staging were upstaged with the use of FDG-PET. Despite comparable therapy, upstaging with FDG-PET predicts poor 2-year survival

  3. Positron emission tomography suggests that the rate of progression of idiopathic parkinsonism is slow

    International Nuclear Information System (INIS)

    Bhatt, M.H.; Snow, B.J.; Martin, W.R.; Pate, B.D.; Ruth, T.J.; Calne, D.B.

    1991-01-01

    The authors performed sequential positron emission tomography scans with 6-[18F]fluoro-L-dopa in 9 patients with idiopathic parkinsonism and 7 age-matched normal control subjects to compare changes in the nigrostriatal dopaminergic pathway over time. The mean interval between the scans was 3.3 years for the group with idiopathic parkinsonism and 3.9 years for the control subjects. The scans were analyzed by calculating the ratio of striatal to background radioactivity. Both groups showed statistically significant reductions of striatal uptake over the interval. The rate of decrease was almost identical in each group (p = 0.6). They infer that the usual rate of loss of integrity of the dopaminergic nigrostriatal pathway in patients with idiopathic parkinsonism is slow and the rate of change between the two groups was comparable

  4. Distribution of adoptively transferred porcine T-lymphoblasts tracked by {sup 18}F-2-fluoro-2-deoxy-D-glucose and position emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Eriksson, Olof, E-mail: olof.eriksson@radiol.uu.se [Division of Radiology, Department of Oncology, Radiology, Oncology and Radiation Science, Uppsala University, Uppsala 751 87 (Sweden); Uppsala Imanet AB, GE Healthcare, Uppsala 751 85 (Sweden); Sadeghi, Arian; Carlsson, Bjoern; Eich, Torsten [Division of Immunology, Department of Immunology, Genetics and Pathology, Uppsala University, Uppsala 751 87 (Sweden); Lundgren, Torbjoern [Division of Transplantation Surgery, CLINTEC, Karolinska Institute, Stockholm 171 77 (Sweden); Nilsson, Bo; Toetterman, Thomas; Korsgren, Olle [Division of Immunology, Department of Immunology, Genetics and Pathology, Uppsala University, Uppsala 751 87 (Sweden); Sundin, Anders [Division of Radiology, Department of Oncology, Radiology, Oncology and Radiation Science, Uppsala University, Uppsala 751 87 (Sweden); Department of Radiology, Karolinska University Hospital and Molecular Medicine and Surgery, Karolinska Institute, Stockholm 171 77 (Sweden)

    2011-08-15

    Introduction: Autologous or allogeneic transfer of tumor-infiltrating T-lymphocytes is a promising treatment for metastatic cancers, but a major concern is the difficulty in evaluating cell trafficking and distribution in adoptive cell therapy. This study presents a method of tracking transfusion of T-lymphoblasts in a porcine model by {sup 18}F-2-fluoro-2-deoxy-D-glucose ([{sup 18}F]FDG) and positron emission tomography. Methods: T-lymphoblasts were labeled with the positron-emitting tracer [{sup 18}F]FDG through incubation. The T-lymphoblasts were administered into the bloodstream, and the distribution was followed by positron emission tomography for 120 min. The cells were administered either intravenously into the internal jugular vein (n=5) or intraarterially into the ascending aorta (n=1). Two of the pigs given intravenous administration were pretreated with low-molecular-weight dextran sulphate. Results: The cellular kinetics and distribution were readily quantifiable for up to 120 min. High (78.6% of the administered cells) heterogeneous pulmonary uptake was found after completed intravenous transfusion. The pulmonary uptake was decreased either by preincubating and coadministrating the T-lymphoblasts with low-molecular-weight dextran sulphate or by administrating them intraarterially. Conclusions: The present work shows the feasibility of quantitatively monitoring and evaluating cell trafficking and distribution following administration of [{sup 18}F]FDG-labeled T-lymphoblasts. The protocol can potentially be transferred to the clinical setting with few modifications.

  5. Dynamic 2-[18F]fluoro-2-deoxy-d-glucose positron emission tomography of liver tumours without blood sampling

    International Nuclear Information System (INIS)

    Keiding, S.; Munk, O.L.; Schioett, K.M.; Hansen, S.B.

    2000-01-01

    Positron emission tomography (PET) using 2-[ 18 F]fluoro-2-deoxy-d-glucose (FDG) is a useful diagnostic tool for the detection of tumours. Using dynamic FDG PET, net metabolic clearance of FDG, K, can be calculated by Gjedde-Patlak analysis of the time course of the radioactivity concentrations in tissue and arterial blood. We examined whether time-activity curves (TACs) based on arterial blood sampling could be replaced by TACs obtained from the descending aorta in dynamic PET scans of patients with liver tumours. The study was performed in two parts, using data from dynamic liver scans with arterial blood sampling in human subjects: First, data from four patients with no liver tumours and five patients with liver tumours were used as a training group. Volumes of interest were defined in the descending aorta (aorta VOIs) by four different methods. K values were calculated based on the corresponding TACs and compared with those based on TACs of the arterial blood sample radioactivity concentrations. The aorta VOI which gave K values that were in best agreement with the K values based on the arterial blood sample measurements was called the AORTA-VOI. Use of the AORTA-VOI was subsequently tested in a test group of 19 tumour patients by comparing the K values from the AORTA-VOI with the K values based on the arterial blood sample measurements. The AORTA-VOI consisted of the sum of small regions of interest (ROIs) drawn in the centre of the aorta (approximately six pixels of 2.4 x 2.4 mm per transaxial slice of 3.1 mm thickness) in as many transaxial slices as possible (30-40 slices). There were no statistically significant differences between the two sets of K values. The ratio of K values in tumour tissue to K values in reference tissue was 2.1-9.7:1 (mean, 5.4:1) based on the AORTA TACs, and 2.1-8.4:1 (mean, 4.6:1) based on blood sample TACs (P>0.3). We conclude that arterial blood sampling can be replaced by the present AORTA-VOI in the calculation of the net

  6. Positron emission tomography studies of brain receptors

    International Nuclear Information System (INIS)

    Maziere, B.; Maziere, M.

    1991-01-01

    Probing the regional distribution and affinity of receptors in the brain, in vivo, in human and non human primates has become possible with the use of selective ligands labelled with positron emitting radionuclides and positron emission tomography (PET). After describing the techniques used in positron emission tomography to characterize a ligand receptor binding and discussing the choice of the label and the limitations and complexities of the in vivo approach, the results obtained in the PET studies of various neurotransmission systems: dopaminergic, opiate, benzodiazepine, serotonin and cholinergic systems are reviewed

  7. Positron emission tomography

    International Nuclear Information System (INIS)

    Pavuk, M.

    2003-12-01

    The aim of this project is to provide a simple summary of new trends in positron emission tomography and its basic physical principles. It provides thereby compendious introduction of the trends of the present development in diagnostics using PET systems. A review of available literature was performed. (author)

  8. Fundamentals of positron emission tomography

    International Nuclear Information System (INIS)

    Ostertag, H.

    1989-01-01

    Positron emission tomography is a modern radionuclide method of measuring physiological quantities or metabolic parameters in vivo. The methods is based on: (1) Radioactive labelling with positron emitters; (2) the coincidence technique for the measurement of the annihilation radiation following positron decay; (3) analysis of the data measured using biological models. The basic aspects and problems of the method are discussed. The main fields of future research are the synthesis of new labelled compounds and the development of mathematical models of the biological processes to be investigated. (orig.) [de

  9. Positron emission tomography

    CERN Document Server

    Paans, A M J

    2006-01-01

    Positron Emission Tomography (PET) is a method for measuring biochemical and physiological processes in vivo in a quantitative way by using radiopharmaceuticals labelled with positron emitting radionuclides such as 11C, 13N, 15O and 18F and by measuring the annihilation radiation using a coincidence technique. This includes also the measurement of the pharmacokinetics of labelled drugs and the measurement of the effects of drugs on metabolism. Also deviations of normal metabolism can be measured and insight into biological processes responsible for diseases can be obtained. At present the combined PET/CT scanner is the most frequently used scanner for whole-body scanning in the field of oncology.

  10. Impact of [F-18]-fluoro-ethyl-tyrosine PET imaging on target definition for radiation therapy of high-grade glioma

    DEFF Research Database (Denmark)

    af Rosenschold, Per Munck; Costa, Junia; Engelholm, Svend Aage

    2015-01-01

    BACKGROUND: We sought to assess the impact of amino-acid (18)F-fluoro-ethyl-tyrosine (FET) positron emission tomography (PET) on the volumetric target definition for radiation therapy of high-grade glioma versus the current standard using MRI alone. Specifically, we investigated the influence....... Patients with grade IV glioma were found to be the primary candidates for PET-guided radiation therapy planning....

  11. Imaging Cellular Proliferation in Prostate Cancer with Positron Emission Tomography

    Directory of Open Access Journals (Sweden)

    Hossein Jadvar

    2015-07-01

    Full Text Available Prostate cancer remains a major public health problem worldwide. Imaging plays an important role in the assessment of disease at all its clinical phases, including staging, restaging after definitive therapy, evaluation of therapy response, and prognostication. Positron emission tomography with a number of biologically targeted radiotracers has been demonstrated to have potential diagnostic and prognostic utility in the various clinical phases of this prevalent disease. Given the remarkable biological heterogeneity of prostate cancer, one major unmet clinical need that remains is the non-invasive imaging-based characterization of prostate tumors. Accurate tumor characterization allows for image-targeted biopsy and focal therapy as well as facilitates objective assessment of therapy effect. PET in conjunction with radiotracers that track the thymidine salvage pathway of DNA synthesis may be helpful to fulfill this necessity. We review briefly the preclinical and pilot clinical experience with the two major cellular proliferation radiotracers, [18F]-3’-deoxy-3’-fluorothymidine and [18F]-2’-fluoro-5-methyl-1-beta-D-arabinofuranosyluracil in prostate cancer.

  12. Positron emission tomography imaging--technical considerations

    International Nuclear Information System (INIS)

    Muehllehner, G.; Karp, J.S.

    1986-01-01

    Positron imaging instrumentation has improved rapidly in the last few years. Scanners currently under development are beginning to approach fundamental limits set by positron range and noncolinearity effects. This report reviews the latest developments in positron emission tomography (PET) instrumentation, emphasizing the development of coding schemes that reduce the complexity and cost of high-resolution scanners. The relative benefits of using time-of-flight (TOF) information is discussed as well. 68 references

  13. Differentiation between malignant and benign pathologic fractures with F-18-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Shin, D.S.; Shon, O.J.; Byun, S.J. [Yeungnam University, Department of Orthopedic Surgery College of Medicine, Daegu (Korea); Choi, J.H. [Yeungnam University, Department of Surgical Pathology, College of Medicine, Daegu (Korea); Chun, K.A.; Cho, I.H. [Yeungnam University, Department of Nuclear Medicine, College of Medicine, Daegu (Korea)

    2008-05-15

    To evaluate the efficacy of F-18-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (FDG PET/CT) in differentiating malignant from benign pathologic fractures. F-18 FDG PET/CT was performed on 34 patients with pathologic fractures between May 2004 and June 2007. Fractures were located in tubular bones (26), in the pelvis (six), in the spine (one) and in a rib (one). The FDG uptake pattern at the fracture site was described, whether FDG uptake occurred in the marrow or cortex and soft tissue. Maximum standardized uptake values (SUVmax, the largest value at the region of interest) were measured at the fracture site, including cortical bone, bone marrow and soft tissue. As a reference standard, biopsy was used for 12 patients and clinical follow-up for 22 patients. Sensitivity, specificity and diagnostic accuracy of PET/CT were calculated. There were 19 malignant and 15 benign fractures. In the malignant fractures, PET/CT demonstrated high (mean SUVmax 12.0, range 4.3 to 45.7) F-18 FDG uptake in bone marrow in most cases (17 of 19). In benign fractures, there was low FDG uptake (mean SUVmax 2.9, range 0.6 to 5.5) within cortical bone or adjacent soft tissue around the fracture, rarely in the marrow. There were significant differences in the pattern of intramedullary FDG uptake (P < 0.001) and in the mean SUVmax (P < 0.01) between malignant and benign fractures. The sensitivity, specificity and diagnostic accuracy of F-18 FDG PET/CT were 89.5%, 86.7% and 88.2%, respectively, with a cut-off SUVmax set at 4.7. The time interval between fracture and PET/CT did not significantly influence FDG uptake at the fracture site. F-18 FDG PET/CT reliably differentiated between malignant and benign fractures based on the SUVmax and based on medullary uptake, which was characteristic for malignant fractures. (orig.)

  14. In-situ positron emission of CO oxidation

    NARCIS (Netherlands)

    Vonkeman, K.A.; Jonkers, G.; Wal, van der S.W.A.; Santen, van R.A.

    1993-01-01

    Using a Neuro ECAT positron tomog., the Positron Emission computed Tomog. (PET) was utilized to image the catalytic oxidn. of CO by using CO and CO2, labeled with short lived positron emitting nuclides. Studies were performed over highly dispersed CeO2/g-Al2O3 supported Pt and Rh catalysts. With a

  15. First image from a combined positron emission tomography and field-cycled MRI system.

    Science.gov (United States)

    Bindseil, Geron A; Gilbert, Kyle M; Scholl, Timothy J; Handler, William B; Chronik, Blaine A

    2011-07-01

    Combining positron emission tomography and MRI modalities typically requires using either conventional MRI with a MR-compatible positron emission tomography system or a modified MR system with conventional positron emission tomography. A feature of field-cycled MRI is that all magnetic fields can be turned off rapidly, enabling the use of conventional positron emission tomography detectors based on photomultiplier tubes. In this demonstration, two photomultiplier tube-based positron emission tomography detectors were integrated with a field-cycled MRI system (0.3 T/4 MHz) by placing them into a 9-cm axial gap. A positron emission tomography-MRI phantom consisting of a triangular arrangement of positron-emitting point sources embedded in an onion was imaged in a repeating interleaved sequence of ∼1 sec MRI then 1 sec positron emission tomography. The first multimodality images from the combined positron emission tomography and field-cycled MRI system show no additional artifacts due to interaction between the systems and demonstrate the potential of this approach to combining positron emission tomography and MRI. Copyright © 2010 Wiley-Liss, Inc.

  16. Comparison of five segmentation tools for 18F-fluoro-deoxy-glucose-positron emission tomography-based target volume definition in head and neck cancer.

    Science.gov (United States)

    Schinagl, Dominic A X; Vogel, Wouter V; Hoffmann, Aswin L; van Dalen, Jorn A; Oyen, Wim J; Kaanders, Johannes H A M

    2007-11-15

    Target-volume delineation for radiation treatment to the head and neck area traditionally is based on physical examination, computed tomography (CT), and magnetic resonance imaging. Additional molecular imaging with (18)F-fluoro-deoxy-glucose (FDG)-positron emission tomography (PET) may improve definition of the gross tumor volume (GTV). In this study, five methods for tumor delineation on FDG-PET are compared with CT-based delineation. Seventy-eight patients with Stages II-IV squamous cell carcinoma of the head and neck area underwent coregistered CT and FDG-PET. The primary tumor was delineated on CT, and five PET-based GTVs were obtained: visual interpretation, applying an isocontour of a standardized uptake value of 2.5, using a fixed threshold of 40% and 50% of the maximum signal intensity, and applying an adaptive threshold based on the signal-to-background ratio. Absolute GTV volumes were compared, and overlap analyses were performed. The GTV method of applying an isocontour of a standardized uptake value of 2.5 failed to provide successful delineation in 45% of cases. For the other PET delineation methods, volume and shape of the GTV were influenced heavily by the choice of segmentation tool. On average, all threshold-based PET-GTVs were smaller than on CT. Nevertheless, PET frequently detected significant tumor extension outside the GTV delineated on CT (15-34% of PET volume). The choice of segmentation tool for target-volume definition of head and neck cancer based on FDG-PET images is not trivial because it influences both volume and shape of the resulting GTV. With adequate delineation, PET may add significantly to CT- and physical examination-based GTV definition.

  17. Comparison of Five Segmentation Tools for 18F-Fluoro-Deoxy-Glucose-Positron Emission Tomography-Based Target Volume Definition in Head and Neck Cancer

    International Nuclear Information System (INIS)

    Schinagl, Dominic A.X.; Vogel, Wouter V.; Hoffmann, Aswin L.; Dalen, Jorn A. van; Oyen, Wim J.; Kaanders, Johannes H.A.M.

    2007-01-01

    Purpose: Target-volume delineation for radiation treatment to the head and neck area traditionally is based on physical examination, computed tomography (CT), and magnetic resonance imaging. Additional molecular imaging with 18 F-fluoro-deoxy-glucose (FDG)-positron emission tomography (PET) may improve definition of the gross tumor volume (GTV). In this study, five methods for tumor delineation on FDG-PET are compared with CT-based delineation. Methods and Materials: Seventy-eight patients with Stages II-IV squamous cell carcinoma of the head and neck area underwent coregistered CT and FDG-PET. The primary tumor was delineated on CT, and five PET-based GTVs were obtained: visual interpretation, applying an isocontour of a standardized uptake value of 2.5, using a fixed threshold of 40% and 50% of the maximum signal intensity, and applying an adaptive threshold based on the signal-to-background ratio. Absolute GTV volumes were compared, and overlap analyses were performed. Results: The GTV method of applying an isocontour of a standardized uptake value of 2.5 failed to provide successful delineation in 45% of cases. For the other PET delineation methods, volume and shape of the GTV were influenced heavily by the choice of segmentation tool. On average, all threshold-based PET-GTVs were smaller than on CT. Nevertheless, PET frequently detected significant tumor extension outside the GTV delineated on CT (15-34% of PET volume). Conclusions: The choice of segmentation tool for target-volume definition of head and neck cancer based on FDG-PET images is not trivial because it influences both volume and shape of the resulting GTV. With adequate delineation, PET may add significantly to CT- and physical examination-based GTV definition

  18. [F-18]2-fluoro-2-deoxyglucose (FDG) positron emission tomography after limb salvage surgery: post-surgical appearance, attenuation correction and local complications

    Energy Technology Data Exchange (ETDEWEB)

    Gelfand, Michael J.; Sharp, Susan E. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Nuclear Medicine Division, Cincinnati, OH (United States)

    2015-08-15

    Metal endoprostheses and internal fixation devices cause significant artifacts on CT after limb salvage surgery; positron emission tomography (PET) images should be evaluated for artifacts. (1) To describe [F-18]2-fluoro-2-deoxyglucose (FDG) PET uptake patterns after limb salvage surgery. (2) To determine whether metal endoprostheses and fixation hardware cause significant artifacts on CT attenuation-corrected PET that interfere with diagnostic use of PET/CT after limb salvage surgery. We reviewed 92 studies from 18 patients ages 5-21 years. Diagnoses were osteogenic sarcoma in 14, Ewing sarcoma in 3, and malignant peripheral nerve sheath tumor originating in bone in 1. Nine patients had distal femur/knee endoprostheses, five had lower-extremity bone allografts secured by large metal plates and four had upper-extremity limb salvage procedures. Maximum standardized uptake value was calculated at lower-extremity soft-tissue-endoprosthesis interfaces. In 15 patients with PET/CT imaging, the first PET/CT scan after limb salvage surgery was reviewed for metal artifacts on CT images and for artifacts at locations on PET corresponding to the CT metal artifacts. Increased FDG uptake was consistently present at soft-tissue interfaces with endoprostheses, allografts and internal fixation devices, with little or no FDG uptake at cemented endoprosthesis-bone interfaces. Maximum standardized uptake value at margins of femur/knee endoprostheses ranged from 1.4 to 5.7. In four patients with distal femur/knee endoprostheses, minimal artifact was noted on attenuation-corrected PET images, but image interpretation was not affected. In the other 11 patients who had CT attenuation correction, we detected no artifacts caused by the attenuation correction. CT attenuation correction did not cause artifacts that affected interpretation of attenuation-corrected PET images. (orig.)

  19. [F-18]2-fluoro-2-deoxyglucose (FDG) positron emission tomography after limb salvage surgery: post-surgical appearance, attenuation correction and local complications

    International Nuclear Information System (INIS)

    Gelfand, Michael J.; Sharp, Susan E.

    2015-01-01

    Metal endoprostheses and internal fixation devices cause significant artifacts on CT after limb salvage surgery; positron emission tomography (PET) images should be evaluated for artifacts. (1) To describe [F-18]2-fluoro-2-deoxyglucose (FDG) PET uptake patterns after limb salvage surgery. (2) To determine whether metal endoprostheses and fixation hardware cause significant artifacts on CT attenuation-corrected PET that interfere with diagnostic use of PET/CT after limb salvage surgery. We reviewed 92 studies from 18 patients ages 5-21 years. Diagnoses were osteogenic sarcoma in 14, Ewing sarcoma in 3, and malignant peripheral nerve sheath tumor originating in bone in 1. Nine patients had distal femur/knee endoprostheses, five had lower-extremity bone allografts secured by large metal plates and four had upper-extremity limb salvage procedures. Maximum standardized uptake value was calculated at lower-extremity soft-tissue-endoprosthesis interfaces. In 15 patients with PET/CT imaging, the first PET/CT scan after limb salvage surgery was reviewed for metal artifacts on CT images and for artifacts at locations on PET corresponding to the CT metal artifacts. Increased FDG uptake was consistently present at soft-tissue interfaces with endoprostheses, allografts and internal fixation devices, with little or no FDG uptake at cemented endoprosthesis-bone interfaces. Maximum standardized uptake value at margins of femur/knee endoprostheses ranged from 1.4 to 5.7. In four patients with distal femur/knee endoprostheses, minimal artifact was noted on attenuation-corrected PET images, but image interpretation was not affected. In the other 11 patients who had CT attenuation correction, we detected no artifacts caused by the attenuation correction. CT attenuation correction did not cause artifacts that affected interpretation of attenuation-corrected PET images. (orig.)

  20. Positron emission tomography

    International Nuclear Information System (INIS)

    Lindback, Stig

    1995-01-01

    Positron Emission Tomography (PET) is an advanced nuclear medicine technique used for research at major centres. Unique diagnostic information is obtained from tomographic measurements of the biochemistry and physiology of tissues and organs. In theory, diseases are related to biochemical changes and these can be observed with PET long before any anatomical changes are detectable. In PET the radioactive component is a positron-emitting isotope or 'tracer'. The positrons annihilate with electrons in the body to produce two gamma rays 180° apart; coincidence detection of these gammas provides a very efficient method of determining the spatial distribution of the radioisotope tracer. Because physiological measurements are usually required in a single imaging session, very short-lived isotopes are used to label the tracer molecules; isotope production and labelling is usually carried out in situ. The most commonly used radionuclides are carbon- 11 (half-life 20 minutes), nitrogen-13 (10 minutes), oxygen-15 (2 minutes), and fluorine-18 (110 minutes). A PET system has three major components: - a particle accelerator with targets for production of the positron-emitting isotopes; - chemistry modules for synthesis and labelling of the desired tracers; - and a PET camera for in-vivo measurements of the distribution of the tracer in the body

  1. Positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lindback, Stig [GEMS PET Systems AB, Uppsala (Sweden)

    1995-07-15

    Positron Emission Tomography (PET) is an advanced nuclear medicine technique used for research at major centres. Unique diagnostic information is obtained from tomographic measurements of the biochemistry and physiology of tissues and organs. In theory, diseases are related to biochemical changes and these can be observed with PET long before any anatomical changes are detectable. In PET the radioactive component is a positron-emitting isotope or 'tracer'. The positrons annihilate with electrons in the body to produce two gamma rays 180° apart; coincidence detection of these gammas provides a very efficient method of determining the spatial distribution of the radioisotope tracer. Because physiological measurements are usually required in a single imaging session, very short-lived isotopes are used to label the tracer molecules; isotope production and labelling is usually carried out in situ. The most commonly used radionuclides are carbon- 11 (half-life 20 minutes), nitrogen-13 (10 minutes), oxygen-15 (2 minutes), and fluorine-18 (110 minutes). A PET system has three major components: - a particle accelerator with targets for production of the positron-emitting isotopes; - chemistry modules for synthesis and labelling of the desired tracers; - and a PET camera for in-vivo measurements of the distribution of the tracer in the body.

  2. 6-[{sup 18}F]fluoro-A-85380: an in vivo tracer for the nicotinic acetylcholine receptor

    Energy Technology Data Exchange (ETDEWEB)

    Scheffel, Ursula; Horti, Andrew G.; Koren, Andrei O.; Ravert, Hayden T.; Banta, Jeffrey P.; Finley, Paige A.; London, Edythe D.; Dannals, Robert F. E-mail: robert_dannals@tracer.nm.jhu.edu

    2000-01-01

    6-[{sup 18}F]Fluoro-3-(2(S)-azetidinylmethoxy)pyridine (6-[{sup 18}F]fluoro-A-85380 or 6-[{sup 18}F]FA), a new tracer for positron emission tomography, was synthesized by no-carrier-added [{sup 18}F] fluorination of 6-iodo-3-((1-tert-butoxycarbonyl-2(S)-azetidinyl)methoxy)pyridine followed by acidic deprotection. 6-[{sup 18}F]FA followed the regional densities of brain nicotinic acetylcholine receptors (nAChRs) reported in the literature. Evidence of binding to nAChRs and high specificity of the binding in vivo was demonstrated by inhibition with nAChR selective ligands as well as with unlabeled 6-FA. A preliminary toxicology study of the 6-FA showed a relatively low biological effect.

  3. Positron emission tomography. Positronemisionstomografi

    Energy Technology Data Exchange (ETDEWEB)

    Bolwig, T G; Haunsoe, S; Dahlgaard Hove, J; Hesse, B; Hoejgard, L; Jensen, M; Paulson, O B; Hastrup Svendsen, J; Soelvsten Soerensen, S

    1994-10-01

    Positron emission tomography (PET) is a method for quantitative imaging of regional physiological and biochemical parameters. Positron emitting radioactive isotopes can be produced by a cyclotron, eg. the biologically important carbon ([sup 11]C), oxygen ([sup 15]O), and nitrogen ([sup 13]N) elements. With the tomographic principles of the PET scanner the quantitative distribution of the administered isotopes can be determined and images can be provided as well as dynamic information on blood flow, metabolism and receptor function. In neurology PET has been used for investigations on numerous physiological processes in the brain: circulation, metabolism and receptor studies. In Parkinson's disease PET studies have been able to localize the pathology specifically, and in early stroke PET technique can outline focal areas with living but non-functioning cells, and this could make it possible to intervene in this early state. With positron emission tomography a quantitative evaluation of myocardial blood flow, glucose and fatty acid metabolism can be made as well as combined assessments of blood flow and metabolism. Combined studies of blood flow and metabolism can determine whether myocardial segments with abnormal motility consist of necrotic or viable tissue, thereby delineating effects of revascularisation. In the future it will probably be possible to characterize the myocardial receptor status in different cardiac diseases. The PET technique is used in oncology for clinical as well as more basic research on tumor perfusion and metabolism. Further, tumor uptake of positron labelled cytotoxic drugs might predict the clinical benefit of treatment. (au) (19 refs.).

  4. Effects of misonidazole, irradiation and hyperthermia on lysosomal enzyme activity in mouse tumours

    International Nuclear Information System (INIS)

    Barratt, G.M.; Wills, E.D.

    1981-01-01

    Male C3H mice bearing transplanted tumours were treated with hyperthermia, gamma radiation and the radiosensitising drug misonidazole. The activity of tumour lysosomal acid phosphatase and β-glucuronidase was determined using quantitative cytochemical techniques which measure both lysosomal membrane permeability and enzyme activity. Misonidazole had no effect on the membrane permeability or enzyme activity of tumour lysosomes 1 hr after injection; but 25 hr after the drug treatment the permeability of the lysosomal membrane to the substrate was increased to 1.7 times control. Increases in the lysosomal enzyme activity and membrane permeability were observed 1 hr after combined treatment with misonidazole and irradiation, although neither the drug nor irradiation given alone affected the lysosomes 1 hr after treatment. Twenty-five hours after treatment of tumours with misonidazole given 25 minutes before irradiation of tumours, permeability of the lysosomal membrane had increased to 2.3 times the control. The effects of the irradiation and the radio-sensitisers were thus synergistic. Hyperthermic treatment of tumours increased and misonidazole decreased the lysosomal membrane permeability and enzyme activity measured immediately after exposure. Thus misonidazole and irradiation act synergistically to cause increased lysosomal activity but misonidazole depresses the effect of hyperthermia on lysosomes. (author)

  5. Speech disorders in olivopontocerebellar atrophy correlate with positron emission tomography findings

    International Nuclear Information System (INIS)

    Kluin, K.J.; Gilman, S.; Markel, D.S.; Koeppe, R.A.; Rosenthal, G.; Junck, L.

    1988-01-01

    We compared the severity of ataxic and spastic dysarthria with local cerebral metabolic rates for glucose (lCMRGlc) in 30 patients with olivopontocerebellar atrophy (OPCA). Perceptual analysis was used to examine the speech disorders, and rating scales were devised to quantitate the degree of ataxia and spasticity in the speech of each patient. lCMRGlc was measured with 18 F-2-fluoro-2-deoxy-D-glucose and positron emission tomography (PET). PET studies revealed marked hypometabolism in the cerebellar hemispheres, cerebellar vermis, and brainstem of OPCA patients compared with 30 control subjects. With data normalized to the cerebral cortex, a significant inverse correlation was found between the severity of ataxia in speech and the lCMRGlc within the cerebellar vermis, cerebellar hemispheres, and brainstem, but not within the thalamus. No significant correlation was found between the severity of spasticity in speech and lCMRGlc in any of these structures. The findings support the view that the severity of ataxia in speech in OPCA is related to the functional activity of the cerebellum and its connections in the brainstem

  6. Positron emission tomography

    International Nuclear Information System (INIS)

    Marchenkov, N.S.

    2000-01-01

    The foundations of the positron emission tomography (PET), widely used for the medical diagnostics, are considered. The brief description of the cyclotron for production of radionuclides, applied in the PET, the target devices for manufacturing the position emitters, the moduli for the radiopharmaceuticals synthesis (RPS) for the PET is presented. The necessity and concept of complete automation of the RPS for the PET are discussed [ru

  7. Redistribution of whole-body energy metabolism by exercise. A positron emission tomography study

    International Nuclear Information System (INIS)

    Masud, M.M.; Miyake, Masayasu; Watanuki, Shoichi; Itoh, Masatoshi; Tashiro, Manabu; Fujimoto, Toshihiko

    2009-01-01

    Our aim was to evaluate changes in glucose metabolism of skeletal muscles and viscera induced by different workloads using 18 F-2-fluoro-2-deoxyglucose ([ 18 F]FDG) and three-dimensional positron emission tomography (3-D PET). Five male volunteers performed ergometer bicycle exercise for 40 min at 40% and 70% of the maximal O 2 consumption (VO 2max ). [ 18 ]FDG was injected 10 min later following the exercise task. Whole-body 3-D PET was performed. Five other male volunteers were studied as a control to compare with the exercise group. The PET image data were analyzed using manually defined regions of interest to quantify the regional metabolic rate of glucose (rMRGlc). Group comparisons were made using analysis of variance, and significant differences (P 18 F]FDG-PET can be used as an index of organ energy metabolism for moderate exercise workloads (70% VO 2max ). The results of this investigation may contribute to sports medicine and rehabilitation science. (author)

  8. Usefulness of positron emission tomography (TEP) in the assessment of osteo-articular prosthesis

    International Nuclear Information System (INIS)

    Maldonado, A.; Suarez, J.P.; Dominguez, M.L.

    2004-01-01

    Joint arthroplasty is performed with increasing frequency as the population ages. Loosening or infection of the prosthesis is a relatively common event that can limit the lifetime of a prosthesis. Accuracy differentiation between aseptic and septic loosening of the prosthesis remains a challenge because of the consequences for patient management. Moreover, an early diagnosis of infected hip prosthesis is very important for optimal and cost-effective management. Various approaches have developed to visualize infection and inflammation by nuclear medicine techniques. Recently positron emission tomography (PET) with fluorine-l8 labelled 2 fluoro-2-deoxyglucose ( 18 F-FDG) has been shown to delineate infectious and inflammatory foci with high sensitivity owing to the increased glucose metabolism in inflammatory cells. In this paper we review the role of FDG-PET in this common differential diagnosis in patients with total knee and hip prostheses. Different patterns of FDG-PET interpretation have been described as wed as methodological aspects. (author)

  9. Radiosensitization of mammalian cells by misonidazole and oxygen: DNA damage exposed by Micrococcus luteus enzymes

    International Nuclear Information System (INIS)

    Skov, K.A.; Palcic, B.; Skarsgard, L.D.

    1979-01-01

    When misonidazole is present during irradiation of hypoxic mammalian cells, an enhancement of single-strand breaks (SSB) in DNA is observed. Oxygen also enhances SSB, presumably in a manner similar to that of misonidazole. The dose-modifying factor (DMF) for 15 mM misonidazole was found to be 3.4, compared to an oxygen enhancement ratio (OER) of 3.5. Another class of DNA damage, namely, sites exposed by an extract of Micrococcus luteus, was examined. Radiation-induced M. luteus extract-sensitive sites (MLS) were also found to be enhanced by the presence of misonidazole or molecular oxygen. The DMF for this damage by 15 mM misonidazole was 1.6 while the OER was 2.5. The ratio of MLS to SSB is approximately 1.25 under hypoxia, 0.9 in the presence of oxygen, and 0.6 in the presence of 15 mM misonidazole under hypoxic conditions. Incubation with misonidazole under conditions which are toxic to mammalian cells (37 0 C, hypoxia), and which result in many SSB, produces no detectable lesions sensitive to the M. luteus extract

  10. Reaction of misonidazole with DNA radicals and its effect on the template activity of DNA

    International Nuclear Information System (INIS)

    Endoh, Daiji; Kuwabara, Mikinori; Sato, Fumiaki; Yoshii, Giichi.

    1985-01-01

    After calf thymus DNA was gamma-irradiated in the solid state in vacuo and subsequently dissolved in aqueous solution containing misonidazole (3 mM) under hypoxic condition, the frequency of single-strand breaks and alkali-labile sites in DNA and the amount of misonidazole bound to DNA were measured. The presence of misonidazole converted the precursor radicals, which otherwise results in single-strand breaks, to alkali-labile sites, and the amount of alkali-labile sites increased linearly with increasing radiation dose. The amount of misonidazole bound to DNA also increased linearly with increasing radiation dose. The biological meaning of the changes in the frequency of single-strand breaks and alkali-labile sites by the reaction of misonidazole with DNA radicals and of binding misonidazole with DNA was examined using a model system to measure the template activity of DNA for RNA synthesis in vitro. The conversion of DNA radicals to alkali-labile sites protected the radiation-induced decrease in the template activity of DNA, while the adduct formation of misonidazole had no effect on it. (author)

  11. Positron emission tomography: Which indications, which benefits?; Tomographie par emission de positons (TEP): quelles indications, quels benefices?

    Energy Technology Data Exchange (ETDEWEB)

    Chassoux, F. [Ctr Hosp St Anne, Serv Neurochirurg, F-75014 Paris (France); Chassoux, F.; Chiron, C. [CEA, I2BM, Serv Hosp Frederic Joliot, F-91 Orsay (France); Chiron, C. [Hop Necker Enfants Malad, INSERM, U663, F-75015 Paris (France); Chassoux, F.; Chiron, C. [Univ Paris 06, F-75005 Paris (France)

    2008-07-01

    Positron emission tomography (PET) is currently used in the pre-surgical workup for drug-resistant partial epilepsies in addition to MRI. Inter-ictal metabolism is studied in clinical practice using {sup 18}fluoro-desoxy-glucose ({sup 18}FDG). In medial temporal lobe epilepsy (MTLE) associated with hippocampal sclerosis, hypo-metabolism ipsilateral to the epileptogenic focus is found in 70-90% of cases. However, hypo-metabolism is larger than the structural lesion observed on MRI and includes the epileptogenic zone and ictal discharge spread areas. Hypo-metabolism is related to surgical outcome and cognitive disturbances in MTLE. Although the usefulness of PET appears less well-established in extra-temporal lobe epilepsy and in children, its sensitivity may be improved by co-registration and superimposition of PET on MRI at any age. Focal hypo-metabolism can be easily detected by visual analysis, allowing detection of minor gyral abnormalities that may correspond to focal cortical dysplasias. Moreover, in cases of negative MRI, focal hypo-metabolism findings may help invasive monitoring planning and deep electrode placement for SEEG, and finally improve surgical outcome. (authors)

  12. Role of microsomal enzyme inducers in the reduction of misonidazole neurotoxicity

    Energy Technology Data Exchange (ETDEWEB)

    Jones, D.H.; Bleehen, N.M.; Workman, P.; Smith, N.C. (Cambridge Univ. (UK). Dept. of Clinical Oncology and Radiotherapeutics; Addenbrooke' s Hospital, Cambridge (UK))

    1983-11-01

    It has been shown that phenytoin, 300 mg daily for one week, produces consistent hepatic microsomal enzyme induction, resulting in a decrease of 25% in misonidazole half-life, without causing any toxicity per se. A longer period of administration gives only a slightly greater induction. Phenobarbitone in a daily dose of 90 mg causes a reduction of 18% and 23% in misonidazole half-life after 1 and 2 weeks' pre-treatment respectively, but is less suitable clinically because of its sedative effect. A further series of studies using phenytoin as the inducing agent has shown that, despite adequate enzyme induction and increased misonidazole metabolism, it is impossible to increase the total dose of misonidazole beyond the usually accepted value of 12 g/m/sup 2/ because of unacceptable neuropathy (a rate of 50% at a dose of 14 g/m/sup 2/ over three weeks). In single doses of above 3.0-4.0 g of misonidazole, severe nausea and vomiting are prominent, so that this side effect is a determining factor in the treatment fractionation. Audiometric studies show no correlation between the incidence of peripheral neuropathy and abnormal audiograms, and have no value in the early prediction of neurotoxicity.

  13. Hypoxic fraction and binding of misonidazole in EMT6/Ed multicellular tumor spheroids

    International Nuclear Information System (INIS)

    Franko, A.J.

    1985-01-01

    Misonidazole has been shown to bind selectively to hypoxic cells in tissue culture and to cells which are presumed to be chronically hypoxic in EMT6 spheroids and tumors. Thus it has considerable potential as a marker of hypoxic cells in vivo. To further evaluate this potential EMT6/Ed spheroids were used to quantitate misonidazole binding under conditions which resulted in hypoxic fractions between 0 and 1. The patterns of binding of 14 C-labeled misonidazole determined by autoradiography were consistent with the regions of radiobiological hypoxia as predicted by oxygen diffusion theory. The overall uptake of 3 H-labeled misonidazole by spheroids correlated well with the hypoxic fraction, although binding to aerobic cells and necrotic tissue contributed appreciably to the total label in the spheroids. It is concluded that misonidazole is an excellent marker of hypoxia in EMT6/Ed spheroids at the microscopic level, and the total amount bound per spheroid provides a potentially useful measure of the hypoxic fraction

  14. Application of mathematical removal of positron range blurring in positron emission tomography

    International Nuclear Information System (INIS)

    Haber, S.F.; Derenzo, S.E.; Uber, D.

    1990-01-01

    The range of positrons in tissue is an important limitation to the ultimate spatial resolution achievable in positron emission tomography. In this work the authors have applied a Fourier deconvolution technique to remove range blurring in images taken by the Donner 600-crystal positron tomograph. Using phantom data, the authors have found significant improvement in the image quality and the FWHM for both 68 Ga and 82 Rb. These were successfully corrected so that the images and FWHM almost matched those of 18 F which has negligible positron range. However, statistical noise was increased by the deconvolution process and it was not practical to recover the full spatial resolution of the tomograph

  15. [7α-18F]fluoro-17α-methyl-5α-dihydrotestosterone: a ligand for androgen receptor-mediated imaging of prostate cancer

    International Nuclear Information System (INIS)

    Garg, Pradeep K.; Labaree, David C.; Hoyte, Robert M.; Hochberg, Richard B.

    2001-01-01

    We have synthesized a 18 F-labeled androgen, [7α- 18 F]fluoro-17α-methyl-5α-dihydrotestosterone, in a no-carrier-added radiosynthesis by exchange of 18 F- (tetrabutylammonium fluoride) with the 7β-tosyloxy of 17α-methyl-5α-dihydrotestosterone. The nonradioactive steroid binds with high affinity and specificity to the androgen receptor and binds poorly, if at all, to other steroid receptors and plasma sex hormone binding globulin. The 7α- 18 F-androgen concentrates markedly in the prostate of rats by an androgen receptor-dependent mechanism. It is likely that [7α- 18 F]fluoro-17α-methyl-5α-dihydrotestosterone will be an excellent positron emission tomography imaging agent for prostate cancer

  16. Positron emission tomographic scan investigations of Huntington's disease: cerebral metabolic correlates of cognitive function

    International Nuclear Information System (INIS)

    Berent, S.; Giordani, B.; Lehtinen, S.; Markel, D.; Penney, J.B.; Buchtel, H.A.; Starosta-Rubinstein, S.; Hichwa, R.; Young, A.B.

    1988-01-01

    Fifteen drug-free patients with early to mid-stage Huntington's disease (HD) were evaluated with positron emission tomographic (PET) scans of 18 F-2-fluoro-2-deoxy-D-glucose uptake and quantitative measures of neurological function, learning, memory, and general intelligence. In comparison with a group of normal volunteers, the HD patients showed lower metabolism in both caudate (p less than 0.001) and putamen (p less than 0.001) on PET scans. A significant and positive relationship was found between neuropsychological measures of verbal learning and memory and caudate metabolism in the patient group but not in the normal group. Visual-spatial learning did not reflect a similar pattern, but performance intelligence quotient was positively related to both caudate and putamen metabolism in the HD group. Vocabulary level was unrelated to either brain structure. Discussion focuses on these and other observed brain-behavior relationships and on the implications of these findings for general behaviors such as those involved in coping and adaptation

  17. Comparison of Amino Acid Positron Emission Tomographic Radiotracers for Molecular Imaging of Primary and Metastatic Brain Tumors

    Directory of Open Access Journals (Sweden)

    Csaba Juhász

    2014-08-01

    Full Text Available Positron emission tomography (PET is an imaging technology that can detect and characterize tumors based on their molecular and biochemical properties, such as altered glucose, nucleoside, or amino acid metabolism. PET plays a significant role in the diagnosis, prognostication, and treatment of various cancers, including brain tumors. In this article, we compare uptake mechanisms and the clinical performance of the amino acid PET radiotracers (L-[methyl-11C]methionine [MET], 18F-fluoroethyl-tyrosine [FET], 18F-fluoro-L- dihydroxy-phenylalanine [FDOPA], and 11C-alpha-methyl-L-tryptophan [AMT] most commonly used for brain tumor imaging. First, we discuss and compare the mechanisms of tumoral transport and accumulation, the basis of differential performance of these radioligands in clinical studies. Then we summarize studies that provided direct comparisons among these amino acid tracers and to clinically used 2-deoxy-2[18F]fluoro-D-glucose [FDG] PET imaging. We also discuss how tracer kinetic analysis can enhance the clinical information obtained from amino acid PET images. We discuss both similarities and differences in potential clinical value for each radioligand. This comparative review can guide which radiotracer to favor in future clinical trials aimed at defining the role of these molecular imaging modalities in the clinical management of brain tumor patients.

  18. Sensitivity of 2-[18F]fluoro-2-deoxyglucose positron emission tomography for advanced colorectal neoplasms: a large-scale analysis of 7505 asymptomatic screening individuals.

    Science.gov (United States)

    Sekiguchi, Masau; Kakugawa, Yasuo; Terauchi, Takashi; Matsumoto, Minori; Saito, Hiroshi; Muramatsu, Yukio; Saito, Yutaka; Matsuda, Takahisa

    2016-12-01

    The sensitivity of 2-[ 18 F]fluoro-2-deoxyglucose positron emission tomography (FDG-PET) for advanced colorectal neoplasms among healthy subjects is not yet fully understood. The present study aimed to clarify the sensitivity by analyzing large-scale data from an asymptomatic screening population. A total of 7505 asymptomatic screenees who underwent both FDG-PET and colonoscopy at our Cancer Screening Division between February 2004 and March 2013 were analyzed. FDG-PET and colonoscopy were performed on consecutive days, and each examination was interpreted in a blinded fashion. The results of the two examinations were compared for each of the divided six colonic segments, with those from colonoscopy being set as the reference. The relationships between the sensitivity of FDG-PET and clinicopathological features of advanced neoplasms were also evaluated. Two hundred ninety-one advanced neoplasms, including 24 invasive cancers, were detected in 262 individuals. Thirteen advanced neoplasms (advanced adenomas) were excluded from the analysis because of the coexistence of lesions in the same colonic segment. The sensitivity, specificity, and positive and negative predictive values of FDG-PET for advanced neoplasms were 16.9 % [95 % confidence interval (CI) 12.7-21.8 %], 99.3 % (95 % CI 99.2-99.4 %), 13.5 % (95 % CI 10.1-17.6 %), and 99.4 % (95 % CI 99.3-99.5 %), respectively. The sensitivity was lower for lesions with less advanced histological grade, of smaller size, and flat-type morphology, and for those located in the proximal part of the colon. FDG-PET is believed to be difficult to use as a primary screening tool in population-based colorectal cancer screening because of its low sensitivity for advanced neoplasms. Even when it is used in opportunistic cancer screening, the limit of its sensitivity should be considered.

  19. The role of microsomal enzyme inducers in the reduction of misonidazole neurotoxicity

    International Nuclear Information System (INIS)

    Jones, D.H.; Bleehen, N.M.; Workman, P.; Smith, N.C.

    1983-01-01

    It has been shown that phenytoin, 300 mg daily for one week, produces consistent hepatic microsomal enzyme induction, resulting in a decrease of 25% in misonidazole half-life, without causing any toxicity per se. A longer period of administration gives only a slightly greater induction. Phenobarbitone in a daily dose of 90 mg causes a reduction of 18% and 23% in misonidazole half-life after 1 and 2 weeks' pre-treatment respectively, but is less suitable clinically because of its sedative effect. A further series of studies using phenytoin as the inducing agent has shown that, despite adequate enzyme induction and increased misonidazole metabolism, it is impossible to increase the total dose of misonidazole beyond the usually accepted value of 12 g/m 2 because of unacceptable neuropathy (a rate of 50% at a dose of 14 g/m 2 over three weeks). In single doses of above 3.0-4.0 g of misonidazole, severe nausea and vomiting are prominent, so that this side effect is a determining factor in the treatment fractionation. Audiometric studies show no correlation between the incidence of peripheral neuropathy and abnormal audiograms, and have no value in the early prediction of neurotoxicity. (author)

  20. Experimental study on central nervous toxicity of 'misonidazole' a hypoxic cell radiosensitizer

    International Nuclear Information System (INIS)

    Takahashi, Iku

    1981-01-01

    'Misonidazole', a radiosensitizer for hypoxic cells is expected to be applied to the treatment of malignant tumors, but its side effect becomes a subject of study, because its effective dose is close to its lethal dose. The auther performed experiments with mice on the central nervous toxicity, which is the most lethal of the side effects of Misonidazole, with the following results; 1. The abrupt death seen after the administration of a large dose of Misonidazole was attributable to the central nervous toxicity. LD 50 for d.d. strain mouse was 1.55 mg per body weight g. 2. The used mice always developed convulsion before death. But the administration of anticonvulsant failed to free them from death. 3. Autopsy findings were such abnormal ones as the degeneration and exfoliation of nerve cells and diapedetic focus. After sacrifice, however, no findings indicative of disturbance of central nerve could be detected. 4. Misonidazole, even in a small divided dose, left intracerebral retention, though slightly, indicating that its accumulation in the brain would be increased with increase in the dose. 5. The disturbance of central nerve was not exacerbated by the whole brain irradiation with Misonidazole. (author)

  1. The metabolism of the human brain studied with positron emission tomography

    International Nuclear Information System (INIS)

    Greitz, T.; Ingvar, D.H.; Widen, L.

    1985-01-01

    This volume presents coverage of the use of positron emission tomography (PET) to study the human brain. The contributors assess new developments in high-resolution positron emission tomography, cyclotrons, radiochemistry, and tracer kinetic models, and explore the use of PET in brain energy metabolism, blood flow, and protein synthesis measurements, receptor analysis, and pH determinations, In addition, they discuss the relevance and applications of positron emission tomography from the perspectives of physiology, neurology, and psychiatry

  2. Positron emission tomography imaging of gene expression

    International Nuclear Information System (INIS)

    Tang Ganghua

    2001-01-01

    The merging of molecular biology and nuclear medicine is developed into molecular nuclear medicine. Positron emission tomography (PET) of gene expression in molecular nuclear medicine has become an attractive area. Positron emission tomography imaging gene expression includes the antisense PET imaging and the reporter gene PET imaging. It is likely that the antisense PET imaging will lag behind the reporter gene PET imaging because of the numerous issues that have not yet to be resolved with this approach. The reporter gene PET imaging has wide application into animal experimental research and human applications of this approach will likely be reported soon

  3. Positron emission tomography camera

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    A positron emission tomography camera having a plurality of detector rings positioned side-by-side or offset by one-half of the detector cross section around a patient area to detect radiation therefrom. Each ring contains a plurality of scintillation detectors which are positioned around an inner circumference with a septum ring extending inwardly from the inner circumference along each outer edge of each ring. An additional septum ring is positioned in the middle of each ring of detectors and parallel to the other septa rings, whereby the inward extent of all the septa rings may be reduced by one-half and the number of detectors required in each ring is reduced. The additional septa reduces the costs of the positron camera and improves its performance

  4. Positron emission tomography neuroimaging in amyotrophic lateral sclerosis: what is new?

    International Nuclear Information System (INIS)

    Quartuccio, N.; Van Weehaeghe, D.; Van Laere, K.; Cistaro, A.; Jonsson, C.; Pagani, M.

    2014-01-01

    Amyotrophic lateral sclerosis (ALS) is a neuro degenerative disease involving upper and lower motor neurons, extra-motor neurons, microglia and astrocytes. The neuro degenerative process results in progressive muscle paralysis and even in cognitive impairment. Within the complex diagnostic work-up, positron emission tomography (PET) represents a valuable imaging tool in the assessment of patients with ALS. PET, by means of different radiotracers (i.e. 18 F-fluorodeoxyglucose, 6-[ 18 F]fluoro-L-dopa, [ 11 C]flumazenil) can assess the status of the wide range of brain regions and neural circuits, which can be affected by ALS. Furthermore, experimental radio compounds have been developed for the evaluation of white matter, which plays a role in the progression of the disease. Here we present a comprehensive review including in different sections the most relevant PET studies: studies investigating ALS and ALS-mimicking conditions (especially primary lateral sclerosis and other neuro degenerative diseases), articles selecting specific subsets of patients (with bulbar or spinal onset), studies investigating patients with familial type of ALS, studies evaluating the role of the white matter in ALS and papers evaluating the diagnostic sensitivity of PET in ALS patients

  5. In-situ positron emission of CO oxidation

    OpenAIRE

    Vonkeman, K.A.; Jonkers, G.; Wal, van der, S.W.A.; Santen, van, R.A.

    1993-01-01

    Using a Neuro ECAT positron tomog., the Positron Emission computed Tomog. (PET) was utilized to image the catalytic oxidn. of CO by using CO and CO2, labeled with short lived positron emitting nuclides. Studies were performed over highly dispersed CeO2/g-Al2O3 supported Pt and Rh catalysts. With a math. model of the reaction kinetics, based on the elementary steps of the catalytic reaction and partially on literature surface science data, the effect of CeO2 promotion and the presence of NO we...

  6. Radiopharmaceutical chemistry for positron emission tomography

    NARCIS (Netherlands)

    Elsinga, PH

    Radiopharmaceutical chemistry includes the selection, preparation, and preclinical evaluation of radiolabeled compounds. This paper describes selection criteria for candidates for positron emission tomography (PET) investigations. Practical aspects of nucleophilic and electrophilic

  7. Clinical experience with the radiosensitizer misonidazole

    International Nuclear Information System (INIS)

    Kogelnik, D.; Szepesi, T.; Kaercher, K.H.; Seitz, W.

    1979-01-01

    From April 1976 to June 1978, 74 cancer patients were treated with multiple doses of misonidazole at the University Clinic for Radiotherapy and Radiobiology of Vienna. Thirtyone patients had inoperable brain tumors or high-grade astrocytomas, the remaining patients suffered from late stages of various extracerebral malignancies. All patients were hospitalized and thoroughly examined for possible side-effects of this currently most promising hypoxic cell radiosensitizer. Neurotoxicity, principally the development of peripheral neuropathies, is the most important limiting factor in the clinical application of misonidazole. With total doses of 12 g/m 2 of surface area a low and acceptable incidence of neuropathies is seen. By extension of the over-all treatment time to 6-8 weeks the total dose may be increased to 15 g/m 2 . (orig.) 891 MG/orig. 892 RDG [de

  8. Three-dimensional patterns of speech-induced cerebral and cerebellar activation in healthy volunteers and in aphasic stroke patients studied by positron emission tomography of 2(18F)-fluorodeoxyglucose

    International Nuclear Information System (INIS)

    Pawlik, G.; Heiss, W.D.; Beil, C.; Gruenewald, G.; Herholz, K.; Wienhard, K.; Wagner, R.

    1987-01-01

    Eight healthy male volunteers and eight moderately aphasic patients with a single cerebral infarctions in the postacute stage, were studied by dynamic positron emission tomography (PET) using the 2(18F)-fluoro-2-deoxy-D-glucose method and a 7-slice positron camera. Because hemispheric speech dominance is commonly thought to be closely related to handedness, subjects were tested by the Oldfield and Bryden questionnaires; the volunteers also had a tracking and pin-sort test. PET studies were performed in random order, both at rest and during spontaneous speech of rather abstract and some biographic content, with a time interval of 2 to 7 days between measurements of the same individual. Data was analyzed by means of weighted, repeated measures of analysis of variance (ANOVA). 11 refs.; 2 figs

  9. Evaluation of whole-body cancer screening using 18F-2-deoxy-2-fluoro-D-glucose positron emission tomography. A preliminary report

    International Nuclear Information System (INIS)

    Terauchi, Takashi; Murano, Takeshi; Daisaki, Hiromitsu; Kanou, Daisuke; Shoda, Hiroko; Kakinuma, Ryutaro; Hamashima, Chisato; Moriyama, Noriyuki; Kakizoe, Tadao

    2008-01-01

    18 F-2-deoxy-2-fluoro-d-glucose positron emission tomography (FDG-PET) is a promising screening modality targeting whole body. However, the validity of PET cancer screening remains to be assessed. Even the screening accuracy for whole-body screening using FDG-PET has not been evaluated. In this study, we investigated the screening accuracy of PET cancer screening. A total of 2911 asymptomatic participants (1629 men and 1282 women, mean age 59.79 years) underwent both FDG-PET and other thorough examinations for multiple organs (gastrofiberscopy, total colonofiberscopy or barium enema, low-dose thin section computed tomography and sputum cytology, abdominal ultrasonography, an assay of prostate-specific antigen, mammography, mammary ultrasonography, Pap smear for the uterine cervix, and magnetic resonance imaging for the endometrium and ovaries) between February 2004 and January 2005, and followed sufficiently. The detection rate, sensitivity, specificity, and positive predictive value of FDG-PET were calculated using cancer data obtained from all examinations along with a 1 year follow-up. From among 2911 participants FDG-PET found 28 cancers, 129 cancers were PET negative. PET-positive cancers comprised seven colorectal cancers, four lung cancers, four thyroid cancers, three breast cancers, two gastric cancers, two prostate cancers, two small intestinal sarcomas (gastrointestinal stromal tumors), one malignant lymphoma, one head and neck malignancy (nasopharyngeal carcinoid tumor), one thymoma, and one hepatocellular carcinoma. PET-negative cancers included 22 gastric cancers and 20 prostate cancers that were essentially difficult to detect using FDG-PET. The overall detection rate, sensitivity, specificity, and positive predictive value were estimated to be 0.96%, 17.83%, 95.15%, and 11.20%, respectively. FDG-PET can detect a variety of cancers at an early stage as part of a whole-body screening modality. The detection rate of PET cancer screening was higher than

  10. Recent developments in positron emission tomography (PET) instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Derenzo, S.E.; Budinger, T.F.

    1986-04-01

    This paper presents recent detector developments and perspectives for positron emission tomography (PET) instrumentation used for medical research, as well as the physical processes in positron annihilation, photon scattering and detection, tomograph design considerations, and the potentials for new advances in detectors. 117 refs., 4 figs., 4 tabs.

  11. Recent developments in positron emission tomography (PET) instrumentation

    International Nuclear Information System (INIS)

    Derenzo, S.E.; Budinger, T.F.

    1986-04-01

    This paper presents recent detector developments and perspectives for positron emission tomography (PET) instrumentation used for medical research, as well as the physical processes in positron annihilation, photon scattering and detection, tomograph design considerations, and the potentials for new advances in detectors. 117 refs., 4 figs., 4 tabs

  12. Misonidazole in patients receiving radical radiotherapy: pharmacokinetic effects of phenytoin tumor response and neurotoxicity

    International Nuclear Information System (INIS)

    Moore, J.L.; Biol, F.I.; Patterson, I.C.M.; Dawes, P.J.D.K.; Henk, J.M.

    1982-01-01

    In 1978, a pilot study began of 29 patients with advanced tumors of the head and neck. The study showed an initial peripheral neuropathy rate of 55%, despite a dose limitation of 12 g/m 2 of misonidazole. Tumor response at 9 months was most encouraging. We are now able to examine tumor response and persistence of neuropathy in these patients 2 1/2 years after radical radiotherapy. The results are comparable with those obtained with hyperbaric oxygen in a clinical trial at this center during the 1970's. Neuropathy was a serious side effect but the drug phenytoin has been shown to shorten the half-life of misonidazole. We have examined the effect of phenytoin on the pharmacokinetics of misonidazole in 13 patients who received radical radiotherapy for advanced head and neck tumors or oesophageal tumors. Misonidazole was given in multiple doses, i.e. daily or weekly as it would be used in conventional therapy. Phenytoin was given either daily throughout treatment, or it was withdrawn during treatment. There were dramatic changes in the half-life of misonidazole, but the concentration at the time of irradiation was little affected. The significant changes in the half-life of misonidazole and the increased concentration of the metabolite desmethylmisonidazole are discussed

  13. The practicality of high magnification imaging by positron emission

    International Nuclear Information System (INIS)

    Hulett, L.D. Jr.; Pendyala, S.

    1988-01-01

    The positron emission microscope has the capability of contrasting areas having high concentrations of monatomic vacancies and other defects. Since the positrons traveling through the specimen will have energies of the same magnitude as that of valence electrons, image contrast will be sensitive to the chemistry of the specimen. In the near future resolutions of 10 nm or lower will be achieved. Whether or not optical aberrations will permit one atom resolution is not clear. For one atom resolution to be obtained positron emission fluxes must be brightness enhanced to 10 11 sec/sup/minus/1/cm/sup/minus/2/ or greater. 5 refs., 1 fig

  14. Ionization and positron emission in giant quasiatoms

    International Nuclear Information System (INIS)

    Soff, G.; Reinhardt, J.; Reus, T. de; Wietschorke, K.H.; Schaefer, A.; Mueller, B.; Greiner, W.; Mueller, U.; Schlueter, P.

    1985-07-01

    Electron excitation processes in superheavy quasiatoms are treated within a relativistic framework. Theoretical results on K-hole production rates as well as delta-electron and positron spectra are compared with experimental data. It is demonstrated that the study of heavy ion collisions with nuclear time delay promises a signature for the spontaneous positron formation in overcritical systems. Corresponding experimental results are confronted with our theoretical hypothesis. Recent speculations on the origin of the observed peak structures in positron spectra are critically reviewed. Atomic excitations are also employed to obtain information on the course of a nuclear reaction. Using a semiclassical picture we calculate the emission of delta-electrons and positrons in deep-inelastic nuclear reactions. Furthermore some consequences of conversion processes in giant systems are investigated. (orig.)

  15. Positron emission tomography of the lung

    International Nuclear Information System (INIS)

    Wollmer, P.

    1984-01-01

    Positron emission tomography enables the distribution of positron emitting isotopes to be imaged in a transverse plane through the body and the regional concentration of the isotope to be measured quantitatively. This thesis reports some applications of positron emission tomography to studies of pulmonary pathophysiology. Measurements in lung phantoms showed that regional lung density could be measured from a transmission tomogram obtained with an external source of positron emitting isotope. The regional, fractional blood volume was measured after labelling the blood with carbon-11-monoxide. Regional extravascular lung density (lung tissue and interstitial water per unit thoracic volume) was obtained by subtracting fractional blood volume from lung density. Measurements in normal subjects revealed large regional variations in lung density and fractional blood volume in the supine posture. Extravascular lung density showed a more uniform distribution. The technique has been used to study patients with chronic interstitial pulmonary oedema, pulmonary sarcoidosis and fibrosis, pulmonary arterial hypertension and patients with intracardiac, left-to-right shunt. Tomographic measurements of pulmonary tissue concentration of radionuclides are difficult, since corrections for the blood content and the inflation of the lung must be applied. A simultaneous measurement of lung density and fractional blood volume allows such corrections to be made and the extravascular tracer concentration to be calculated. This has been applied to measurements of the tissue penetration of carbon-11-labelled erythromycin in patients with lobar pneumonia. (author)

  16. High-dose irradiation and misonidazole in the treatment of malignant gliomas

    International Nuclear Information System (INIS)

    Kogelnik, H.D.; Kaercher, K.H.; Szepesi, T.; Schratter-Sehn, A.V.

    1982-01-01

    Thirty-three patients with grade III and IV supratentorial astrocytomas who were entered into a radomized two-arm study to evaluate the effect of misonidazole in conjunction with postoperative irradiation are available for analysis. All patients received the same radiation dose: 6650 rads (43 MeV photons) in 31 fractions over 7 1/2 weeks. Misonidazole was given orally 4 to 5 hours before irradiation on those treatment days when fractional radiation doses of 400 rads were used. The cumulative dose of misonidazole was 27 g, corresponding to 12.6 to 16.4 g/m 2 . With a minimum follow-up time of one year, median survival for patients receiving postoperative irradiation had a median survival of 57.1 weeks. The difference in the distribution of survival times between both groups is statistically significant (p < 0.02). From an analysis of variance for age, it cannot be ruled out that the survival difference between the two groups is at least partly due to differences in ages. Side effects of misonidazole were minimal, with only 2 patients experiencing mild paresthesias and 4 noting a transient tinnitus

  17. The norepinephrine transporter in attention-deficit/hyperactivity disorder investigated with positron emission tomography.

    Science.gov (United States)

    Vanicek, Thomas; Spies, Marie; Rami-Mark, Christina; Savli, Markus; Höflich, Anna; Kranz, Georg S; Hahn, Andreas; Kutzelnigg, Alexandra; Traub-Weidinger, Tatjana; Mitterhauser, Markus; Wadsak, Wolfgang; Hacker, Marcus; Volkow, Nora D; Kasper, Siegfried; Lanzenberger, Rupert

    2014-12-01

    Attention-deficit/hyperactivity disorder (ADHD) research has long focused on the dopaminergic system's contribution to pathogenesis, although the results have been inconclusive. However, a case has been made for the involvement of the noradrenergic system, which modulates cognitive processes, such as arousal, working memory, and response inhibition, all of which are typically affected in ADHD. Furthermore, the norepinephrine transporter (NET) is an important target for frequently prescribed medication in ADHD. Therefore, the NET is suggested to play a critical role in ADHD. To explore the differences in NET nondisplaceable binding potential (NET BPND) using positron emission tomography and the highly selective radioligand (S,S)-[18F]FMeNER-D2 [(S,S)-2-(α-(2-[18F]fluoro[2H2]methoxyphenoxy)benzyl)morpholine] between adults with ADHD and healthy volunteers serving as controls. Twenty-two medication-free patients with ADHD (mean [SD] age, 30.7 [10.4] years; 15 [68%] men) without psychiatric comorbidities and 22 age- and sex-matched healthy controls (30.9 [10.6] years; 15 [68%] men) underwent positron emission tomography once. A linear mixed model was used to compare NET BPND between groups. The NET BPND in selected regions of interest relevant for ADHD, including the hippocampus, putamen, pallidum, thalamus, midbrain with pons (comprising a region of interest that includes the locus coeruleus), and cerebellum. In addition, the NET BPND was evaluated in thalamic subnuclei (13 atlas-based regions of interest). We found no significant differences in NET availability or regional distribution between patients with ADHD and healthy controls in all investigated brain regions (F1,41sex nor smoking status influenced NET availability. We determined a significant negative correlation between age and NET availability in the thalamus (R2=0.29; P<.01 corrected) and midbrain with pons, including the locus coeruleus (R2=0.18; P<.01 corrected), which corroborates prior findings of a

  18. Radiopharmaceuticals in positron emission tomography: Radioisotope productions and radiolabelling procedures at the Austin and Repatriation Medical Centre

    International Nuclear Information System (INIS)

    Tochon-Danguy, H.J.; Sachinidis, J.I.; Chan, J.G.; Cook, M.

    1997-01-01

    Positron Emission Tomography (PET) is a technique that utilizes positron-emitting radiopharmaceuticals to map the physiology, biochemistry and pharmacology of the human body. Positron-emitting radioisotopes produced in a medical cyclotron are incorporated into compounds that are biologically active in the body. A scanner measures radioactivity emitted from a patient's body and provides cross-sectional images of the distribution of these radiolabelled compounds in the body. It is the purpose of this paper to review the variety of PET radiopharmaceuticals currently produced at the Austin and Repatriation Medical Centre in Melbourne. Radioisotope production, radiolabelling of molecules and quality control of radiopharmaceuticals will be discussed. A few examples of their clinical applications will be shown as well. During the last five years we achieved a reliable routine production of various radiopharmaceuticals labelled with the four most important positron-emitters: oxygen-15 (t, 1/2 =2min), nitrogen-13 (t 1/2 = 10 min), carbon-11 (t 1/2 =20 min) and fluorine-18 (t 1/2 = 110 min). These radiopharmaceuticals include [ 15 O]oxygen, [ 15 O]carbon monoxide, [ 15 O]carbon dioxide, [ 15 O]water, [ 13 N]ammonia, [ 11 C]flumazenil, [ 11 C]SCH23390, [ 18 F]fluoromisonidazole and [ 18 F]fluoro-deoxy-glucose ([ 18 F]FDG). In addition, since the half life of [ 18 F] is almost two hours, regional distribution can be done, and the Austin and Repatriation Medical Centre is currently supplying [ 18 F]FDG in routine to other hospitals. Future new radiopharmaceuticals development include a [ 18 F]thymidine analog to measure cell proliferation and a [ 11 C]pyrroloisoquinoline to visualize serotonergic neuron abnormalities. (authors)

  19. RELIABILITY OF POSITRON EMISSION TOMOGRAPHY-COMPUTED TOMOGRAPHY IN EVALUATION OF TESTICULAR CARCINOMA PATIENTS.

    Science.gov (United States)

    Nikoletić, Katarina; Mihailović, Jasna; Matovina, Emil; Žeravica, Radmila; Srbovan, Dolores

    2015-01-01

    The study was aimed at assessing the reliability of 18F-fluorodeoxyglucose positron emission tomography-computed tomography scan in evaluation of testicular carcinoma patients. The study sample consisted of 26 scans performed in 23 patients with testicular carcinoma. According to the pathohistological finding, 14 patients had seminomas, 7 had nonseminomas and 2 patients had a mixed histological type. In 17 patients, the initial treatment was orchiectomy+chemotherapy, 2 patients had orchiectomy+chemotherapy+retroperitoneal lymph node dissection, 3 patients had orchiectomy only and one patient was treated with chemotherapy only. Abnormal computed tomography was the main cause for the oncologist to refer the patient to positron emission tomography-computed tomography scan (in 19 scans), magnetic resonance imaging abnormalities in 1 scan, high level oftumor markers in 3 and 3 scans were perforned for follow-up. Positron emission tomography-computed tomography imaging results were compared with histological results, other imaging modalities or the clinical follow-up of the patients. Positron emission tomography-computed tomography scans were positive in 6 and negative in 20 patients. In two patients, positron emission tomography-computed tomography was false positive. There were 20 negative positron emission omography-computed tomography scans perforned in 18 patients, one patient was lost for data analysis. Clinically stable disease was confirmed in 18 follow-up scans performed in 16 patients. The values of sensitivty, specificity, accuracy, and positive- and negative predictive value were 60%, 95%, 75%, 88% and 90.5%, respectively. A hgh negative predictive value obtained in our study (90.5%) suggests that there is a small possibility for a patient to have future relapse after normal positron emission tomography-computed tomography study. However, since the sensitivity and positive predictive value of the study ire rather low, there are limitations of positive

  20. Positron emission tomography in drug development and drug evaluation

    NARCIS (Netherlands)

    Paans, AMJ; Vaalburg, W

    2000-01-01

    Positron Emission Tomography (PET) is an imaging modality which can determine biochemical and physiological processes in vivo in a quantitative way by using radiopharmaceuticals labeled with positron emitting radionuclides as C-11, N-13, O-15 and F-18 and by measuring the annihilation radiation

  1. Effects of co-dergocrine mesylate (Hydergine) in multi-infarct dementia as evaluated by positron emission tomography

    International Nuclear Information System (INIS)

    Nagasawa, Haruo; Kogure, Kyuya; Kawashima, Koichiro; Ido, Tatsuo; Itoh, Masatoshi; Hatazawa, Jun.

    1990-01-01

    Three female patients aged from 74 to 79 with multi-infarct dementia were studied using positron emission tomography (PET) to assess the effect of co-dergocrine mesylate (Hydergine) on cerebral glucose metabolism. The cerebral glucose utilization (CMRGlc) of each patient was evaluated by PET scan using 2-deoxy-[ 18 F]-2-fluoro-D-glucose (FDG). Following the first PET study, 0.04 mg/kg of co-dergocrine mesylate was injected intravenously with 250 ml saline solution, and then the second PET study was performed. The CMRGlc was determined from the images of the PET scan and the radioactivity of 18 F in the plasma. After the administration of co-dergocrine mesylate, the value of CMRGlc increased significantly in the cerebral cortex (p<0.01 and p<0.05) and basal ganglia (p<0.05) compared with values before the administration, but no significant increase was found in the centrum semiovale. These results suggest that co-dergocrine mesylate stimulates glucose metabolism of neurons in the human brain. (author)

  2. Mu-opiate receptors measured by positron emission tomography are increased in temporal lobe epilepsy.

    Science.gov (United States)

    Frost, J J; Mayberg, H S; Fisher, R S; Douglass, K H; Dannals, R F; Links, J M; Wilson, A A; Ravert, H T; Rosenbaum, A E; Snyder, S H

    1988-03-01

    Neurochemical studies in animal models of epilepsy have demonstrated the importance of multiple neurotransmitters and their receptors in mediating seizures. The role of opiate receptors and endogenous opioid peptides in seizure mechanisms is well developed and is the basis for measuring opiate receptors in patients with epilepsy. Patients with complex partial seizures due to unilateral temporal seizure foci were studied by positron emission tomography using 11C-carfentanil to measure mu-opiate receptors and 18F-fluoro-deoxy-D-glucose to measure glucose utilization. Opiate receptor binding is greater in the temporal neocortex on the side of the electrical focus than on the opposite side. Modeling studies indicate that the increase in binding is due to an increase in affinity or the number of unoccupied receptors. No significant asymmetry of 11C-carfentanil binding was detected in the amygdala or hippocampus. Glucose utilization correlated inversely with 11C-carfentanil binding in the temporal neocortex. Increased opiate receptors in the temporal neocortex may represent a tonic anticonvulsant system that limits the spread of electrical activity from other temporal lobe structures.

  3. Positron emission tomographic imaging of cardiac sympathetic innervation and function

    International Nuclear Information System (INIS)

    Goldstein, D.S.; Chang, P.C.; Eisenhofer, G.; Miletich, R.; Finn, R.; Bacher, J.; Kirk, K.L.; Bacharach, S.; Kopin, I.J.

    1990-01-01

    Sites of uptake, storage, and metabolism of [ 18 F]fluorodopamine and excretion of [ 18 F]fluorodopamine and its metabolites were visualized using positron emission tomographic (PET) scanning after intravenous injection of the tracer into anesthetized dogs. Radioactivity was concentrated in the renal pelvis, heart, liver, spleen, salivary glands, and gall bladder. Uptake of 18F by the heart resulted in striking delineation of the left ventricular myocardium. Pretreatment with desipramine markedly decreased cardiac positron emission, consistent with dependence of the heart on neuronal uptake (uptake-1) for removal of circulating catecholamines. In reserpinized animals, cardiac positron emission was absent within 30 minutes after injection of [ 18 F]-6-fluorodopamine, demonstrating that the emission in untreated animals was from radioactive labeling of the sympathetic storage vesicles. Decreased positron emission from denervated salivary glands confirmed that the tracer was concentrated in sympathetic neurons. Radioactivity in the gall bladder and urinary system depicted the hepatic and renal excretion of the tracer and its metabolites. Administration of tyramine or nitroprusside increased and ganglionic blockade with trimethaphan decreased the rate of loss of myocardial radioactivity. The results show that PET scanning after administration of [ 18 F]fluorodopamine can be used to visualize sites of sympathetic innervation, follow the metabolism and renal and hepatic excretion of catecholamines, and examine cardiac sympathetic function

  4. Parkinson disease and positron tomography

    International Nuclear Information System (INIS)

    Baron, J.C.

    1984-10-01

    Physiopathologic investigations of Parkinson disease and parkinsonian syndrome using positron tomography are briefly reviewed: study of cerebral blood flow and metabolism; effects of L-DOPA; study of dopaminergic receptors and of 18 F-Fluoro-L-DOPA incorporation [fr

  5. Radioprotective effect of misonidazole (Ro-07-0582) on normal canine rectum

    Energy Technology Data Exchange (ETDEWEB)

    Stryker, J.A.; Albert, A.; Abt, A.B.

    1980-10-01

    A single 1500 rad (=15 Gy) dose of 10-MeV X-rays was administered to the pelvis of 20 mongrel dogs. Ten received misonidazole (Ro-07-0582), 100 mg/kg p.o., 4 hours pre-irradiation. Serum misonidazole levels immediately pre-irradiation were 43 +- 10 ..mu..g/ml (mean +- SD). The dogs were euthanized within 3 months post-irradiation. Each rectal specimen was studied for anatomic and histologic pathology and was assigned a Pathologic Alteration Score (PAS) of 1, 2, or 3 in order of increasing severity. The PAS of the rectal specimens from the drug group was 1.6 +- 0.7, and that of the controls 2.3 +- 0.8. The PAS of the drug group was significantly lower than the control group (P = 0.008). The data suggest that misonidazole is a radioprotector for normal tissue.

  6. Positron emission tomography of malignant tumours at head and neck. Evaluation of the diagnostic value of positron emission tomography by comparison with computed tomography

    International Nuclear Information System (INIS)

    Kettler, Nele

    2011-01-01

    Imaging methods for early, accurate diagnosis and aftercare of malignant growths is currently one of the most important research topics. The objective of this thesis is to evaluate the diagnostic value of FDG-positron emission tomography by comparison with computed tomography for patients with squamous cell carcinoma, malignant melanoma or sarcoma at head and neck. Measurement criteria are sensitivity and specificity. A retrospective evaluation of 100 examinations on 85 patients of University clinic Aachen was performed. The examination reports were supported by reports from histology, positron emission tomography and computed tomography. In each case, the histological results were assumed to provide a reliable benchmark. Sensitivity and specificity for the primary tumour site, metastatic lymphatic nodes and defined anatomic structures were compared across all patients. Comparisons were also performed on sub groups separated by gender, cancer type and the time and frequency at which tumours arose. The statistic analysis was done with MedCalc. Results: The results for sensitivity and specificity of the primary tumour site were 86.42% and 42.86%, and 64.71% and 66.07%, for positron emission tomography and computed tomography respectively. The results for the lymphatic nodes were 51.52% and 92.86% and 64.71% and 66.07%. When the constituent anatomic structures were evaluated separately, the specificity was significantly higher. The separation by gender showed no difference. Because the classification by tumor type resulted in samples that were of varying size, a comparison was difficult. For the diagnosis of primary tumours, the examination with positron emission tomography was superior, whereas computed tomography proved more effective for the diagnosis of recurrent tumours. For the diagnosis of the main tumour site, both methods were shown to be equally suitable. For the assessment of lymphatic nodes, positron emission tomography was superior to computed tomography

  7. Clinical impact of 18F-fluorodeoxyglucose positron emission tomography in the diagnosis of neurological diseases

    International Nuclear Information System (INIS)

    Buck, A.; Kamel, E.

    2002-01-01

    In this review it will be discussed in which neurological disorders positron emission tomography can yield important diagnostic information. Because positron emission tomography is an expensive method indications have to be cleary defined. One important question concerns the differentiation of tumor recurrence and scar due to radiation therapy or an operation. The grading of brain tumors is another application. In HIV patients fluorodeoxyglucose positron emission tomography can separate lymphoma and toxoplasmosis. In the evaluation of dementia positron emission tomography can help to clarify the differential diagnosis. Another important area is the presurgical evaluation of epilepsy patients and patients with cerebrovascular disease in whom a surgical revascularization procedure is planned. In extrapyramidal disorders, positron emission tomography can often help to establish the final diagnosis. (author)

  8. Comparison of Diagnostic Performance of Three-Dimensional Positron Emission Mammography versus Whole Body Positron Emission Tomography in Breast Cancer

    Directory of Open Access Journals (Sweden)

    Dong Dai

    2017-01-01

    Full Text Available Objective. To compare the diagnostic performance of three-dimensional (3D positron emission mammography (PEM versus whole body positron emission tomography (WBPET for breast cancer. Methods. A total of 410 women with normal breast or benign or highly suspicious malignant tumors were randomized at 1 : 1 ratio to undergo 3D-PEM followed by WBPET or WBPET followed by 3D-PEM. Lumpectomy or mastectomy was performed on eligible participants after the scanning. Results. The sensitivity and specificity of 3D-PEM were 92.8% and 54.5%, respectively. WBPET showed a sensitivity of 95.7% and specificity of 56.8%. After exclusion of the patients with lesions beyond the detecting range of the 3D-PEM instrument, 3D-PEM showed higher sensitivity than WBPET (97.0% versus 95.5%, P = 0.913, particularly for small lesions (<1 cm (72.0% versus 60.0%, P = 0.685. Conclusions. The 3D-PEM appears more sensitive to small lesions than WBPET but may fail to detect lesions that are beyond the detecting range. This study was approved by the Ethics Committee (E2012052 at the Tianjin Medical University Cancer Institute and Hospital (Tianjin, China. The instrument positron emission mammography (PEMi was approved by China State Food and Drug Administration under the registration number 20153331166.

  9. Positron emission tomography in oncology. Council on Scientific Affairs

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    This report describes the current and potential uses of positron emission tomography in clinical medicine and research related to oncology. Assessment will be possible of metabolism and physiology of tumors and their effects on adjacent tissues. Specific probes are likely to be developed for target sites on tumors, including monoclonal antibodies and specific growth factors that recognize tumors. To date, most oncological applications of positron emission tomography tracers have been qualitative; in the future, quantitative metabolic measurements should aid in the evaluation of tumor biology and response to treatment. 41 references

  10. Positron emission tomography camera

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    A positron emission tomography camera having a plurality of detector rings positioned side-by-side or offset by one-half of the detector cross section around a patient area to detect radiation therefrom. Each detector ring or offset ring includes a plurality of photomultiplier tubes and a plurality of scintillation crystals are positioned relative to the photomultiplier tubes whereby each tube is responsive to more than one crystal. Each alternate crystal in the ring is offset by one-half or less of the thickness of the crystal such that the staggered crystals are seen by more than one photomultiplier tube. This sharing of crystals and photomultiplier tubes allows identification of the staggered crystal and the use of smaller detectors shared by larger photomultiplier tubes thereby requiring less photomultiplier tubes, creating more scanning slices, providing better data sampling, and reducing the cost of the camera. The offset detector ring geometry reduces the costs of the positron camera and improves its performance

  11. Metabolism and pharmacokinetics of the hypoxic cell radiosensitizer and cytotoxic agent, misonidazole, in C3H mice

    International Nuclear Information System (INIS)

    Chin, J.B.; Rauth, A.M.

    1981-01-01

    Misonidazole, a 2-nitroimidazole, is presently of interest because of its radiosensitizing and toxic effects toward hypoxic tumor cells. The plasma and tissue distribution of misonidazole and various products was studied as a function of time and mode of administration in male C3H mice with KHT tumors. Polarographic measurements of nitro-group species in plasma after intravenous or intraperitoneal misonidazole administration indicated apparent half-lives of 1.0 to 1.5 hr. With an oral dose, a multicomponent curve was obtained. [ 14 C]misonidazole, labeled in the 2-position of the imidazole ring, was widely distributed to all tissues tested after intraperitioneal or oral administration. Paper chromatography of plasma and the water-soluble fraction of spleen, liver, kidney, brain, and KHT tumor tissue showed variations in the proportions of misonidazole, its 0-dimethylation product, the aminoimidazole, and low-R/sub F/ products (including glucuronides). There was radioactivity in the gastrointestinal lumen 1 hr after intravenous injection. These studies indicate that differences exist in total drug levels as well as in the proportions of metabolites present in various tissue types. Thus the radiosensitization and toxicity of misonidazole may depend on the particular tissue or tumor under study

  12. Clinical impact of Positron Emission Tomography (PET) on oncological patients and their potentially application context

    International Nuclear Information System (INIS)

    Alonso, O.

    2006-01-01

    (PET) Positron Emission Tomography is a technique of nuclear medicine that has ability of detecting cancer through mechanisms based on molecular alterations of neoplastic processes. This review describes the PET Oncology applications and discusses the potential application of this technology in the sanitary and national academic framework . The most widely used in Oncology plotter is an analogue of laglucosa labelled with fluo: 18F-2-fluoro-2-Deoxy-D-glucose (FDG). In this way, the PET detects tumour retention of FDG, due to the highest glycolytic of cancer cells. In addition, the PET allow the study of the entire body at the same exploratory and some teams are coupled to systems of axial tomography (PET-CT). By ET-FDG, it is possible to diagnose, staging and restaged the majority of cancers, with diagnostic accuracy close to 90 per cent higher than the values provided by the conventional imaging techniques such. It is also possible to know early response to cancer treatments and obtain relevant medical prognosis information. (author) [es

  13. Mycosis fungoides: Positron emission tomography/computed tomography in staging and monitoring the effect of therapy

    International Nuclear Information System (INIS)

    D’Souza, Maria Mathew; D’Souza, Paschal; Sharma, Rajnish; Jaimini, Abhinav; Mondal, Anupam

    2015-01-01

    A 58-year-old woman, diagnosed as a case of mycosis fungoides (MF), underwent [18F]-fluoro-D-glucose positron emission tomography/computed tomography (FDG PET/CT) examination. The study revealed intense FDG uptake in a large ulceroproliferative right thigh lesion, indurated plaques in the chest wall and left thigh, along with multiple sites of cutaneous involvement, axillary and inguinal lymphadenopathy. The patient underwent chemotherapy with CHOP regimen, radiotherapy for the right thigh lesion, along with topical corticosteroids and emollients for the disseminated cutaneous involvement. Repeat [18F]-FDG PET/CT study performed a year later, showed near complete disease regression specifically of the ulceroproliferative lesion and indurated cutaneous plaques, no change in lymphadenopathy, and a subtle diffuse progression of the remaining cutaneous lesions. A multidisciplinary approach to the diagnosis, staging and treatment of MF has long been suggested for optimizing outcomes from management of patients with this disease. This case highlights the potential role of incorporating PET/CT as a single modality imaging technique in the staging and assessment of response to therapy

  14. Radiopharmaceuticals in positron emission tomography: Radioisotope productions and radiolabelling procedures at the Austin and Repatriation Medical Centre

    Energy Technology Data Exchange (ETDEWEB)

    Tochon-Danguy, H.J.; Sachinidis, J.I.; Chan, J.G.; Cook, M. [Austin and Repatriation Medical Centre, Melbourne, VIC (Australia). Centre for Positron Emission Tomography

    1997-10-01

    Positron Emission Tomography (PET) is a technique that utilizes positron-emitting radiopharmaceuticals to map the physiology, biochemistry and pharmacology of the human body. Positron-emitting radioisotopes produced in a medical cyclotron are incorporated into compounds that are biologically active in the body. A scanner measures radioactivity emitted from a patient`s body and provides cross-sectional images of the distribution of these radiolabelled compounds in the body. It is the purpose of this paper to review the variety of PET radiopharmaceuticals currently produced at the Austin and Repatriation Medical Centre in Melbourne. Radioisotope production, radiolabelling of molecules and quality control of radiopharmaceuticals will be discussed. A few examples of their clinical applications will be shown as well. During the last five years we achieved a reliable routine production of various radiopharmaceuticals labelled with the four most important positron-emitters: oxygen-15 (t,{sub 1/2}=2min), nitrogen-13 (t{sub 1/2}= 10 min), carbon-11 (t{sub 1/2}=20 min) and fluorine-18 (t{sub 1/2}= 110 min). These radiopharmaceuticals include [{sup 15}O]oxygen, [{sup 15}O]carbon monoxide, [{sup 15}O]carbon dioxide, [{sup 15}O]water, [{sup 13}N]ammonia, [{sup 11}C]flumazenil, [{sup 11}C]SCH23390, [{sup 18}F]fluoromisonidazole and [{sup 18}F]fluoro-deoxy-glucose ([{sup 18}F]FDG). In addition, since the half life of [{sup 18}F] is almost two hours, regional distribution can be done, and the Austin and Repatriation Medical Centre is currently supplying [{sup 18}F]FDG in routine to other hospitals. Future new radiopharmaceuticals development include a [{sup 18}F]thymidine analog to measure cell proliferation and a [{sup 11}C]pyrroloisoquinoline to visualize serotonergic neuron abnormalities. (authors) 23 refs., 2 tabs.

  15. Homotopic non-local regularized reconstruction from sparse positron emission tomography measurements

    International Nuclear Information System (INIS)

    Wong, Alexander; Liu, Chenyi; Wang, Xiao Yu; Fieguth, Paul; Bie, Hongxia

    2015-01-01

    Positron emission tomography scanners collect measurements of a patient’s in vivo radiotracer distribution. The system detects pairs of gamma rays emitted indirectly by a positron-emitting radionuclide (tracer), which is introduced into the body on a biologically active molecule, and the tomograms must be reconstructed from projections. The reconstruction of tomograms from the acquired PET data is an inverse problem that requires regularization. The use of tightly packed discrete detector rings, although improves signal-to-noise ratio, are often associated with high costs of positron emission tomography systems. Thus a sparse reconstruction, which would be capable of overcoming the noise effect while allowing for a reduced number of detectors, would have a great deal to offer. In this study, we introduce and investigate the potential of a homotopic non-local regularization reconstruction framework for effectively reconstructing positron emission tomograms from such sparse measurements. Results obtained using the proposed approach are compared with traditional filtered back-projection as well as expectation maximization reconstruction with total variation regularization. A new reconstruction method was developed for the purpose of improving the quality of positron emission tomography reconstruction from sparse measurements. We illustrate that promising reconstruction performance can be achieved for the proposed approach even at low sampling fractions, which allows for the use of significantly fewer detectors and have the potential to reduce scanner costs

  16. Serial study of the concentration of misonidazole in human tumors correlated with histologic structure

    International Nuclear Information System (INIS)

    Rich, T.A.; Dische, S.; Saunders, M.I.; Stratford, M.R.L.; Minchinton, A.

    1981-01-01

    Multiple biopsies were obtained from eight patients with malignant tumors during a course of fractionated radiotherapy. An analysis of the total 2-nitroimidazole concentration and a histological examination of the biopsy sample was done on material which appeared macroscopically similar. The parts of the tumor biopsies showing necrosis were found to contain much lower concentrations of nitroimidazole when compared with those found in the samples with well-vascularized and apparently viable tumor. During the course of irradiation changes in misonidazole concentrations were not found when similar histological material was examined. The low values of misonidazole in necrotic regions in human tumors may partly account for the wide variation of misonidazole concentrations reported in the literature (percent tumor/plasma, mean 62.9 +- 34.4 STD). The clinical significance of the microscopic distribution of misonidazole in tumors in unknown but further work in this area may aid in predicting the usefulness of future radiosensitizers

  17. 77 FR 21783 - Guidance on Media Fills for Validation of Aseptic Preparations for Positron Emission Tomography...

    Science.gov (United States)

    2012-04-11

    ...] Guidance on Media Fills for Validation of Aseptic Preparations for Positron Emission Tomography Drugs... Aseptic Preparations for Positron Emission Tomography (PET) Drugs.'' This guidance is intended to help... Preparations for Positron Emission Tomography (PET) Drugs.'' Most PET drugs are designed for parenteral...

  18. The functional neuroanatomy of verbal memory in Alzheimer's disease: [18F]-Fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) correlates of recency and recognition memory.

    Science.gov (United States)

    Staffaroni, Adam M; Melrose, Rebecca J; Leskin, Lorraine P; Riskin-Jones, Hannah; Harwood, Dylan; Mandelkern, Mark; Sultzer, David L

    2017-09-01

    The objective of this study was to distinguish the functional neuroanatomy of verbal learning and recognition in Alzheimer's disease (AD) using the Consortium to Establish a Registry for Alzheimer's Disease (CERAD) Word Learning task. In 81 Veterans diagnosed with dementia due to AD, we conducted a cluster-based correlation analysis to assess the relationships between recency and recognition memory scores from the CERAD Word Learning Task and cortical metabolic activity measured using [ 18 F]-fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET). AD patients (Mini-Mental State Examination, MMSE mean = 20.2) performed significantly better on the recall of recency items during learning trials than of primacy and middle items. Recency memory was associated with cerebral metabolism in the left middle and inferior temporal gyri and left fusiform gyrus (p recognition memory was correlated with metabolic activity in two clusters: (a) a large cluster that included the left hippocampus, parahippocampal gyrus, entorhinal cortex, anterior temporal lobe, and inferior and middle temporal gyri; (b) the bilateral orbitofrontal cortices (OFC). The present study further informs our understanding of the disparate functional neuroanatomy of recency memory and recognition memory in AD. We anticipated that the recency effect would be relatively preserved and associated with temporoparietal brain regions implicated in short-term verbal memory, while recognition memory would be associated with the medial temporal lobe and possibly the OFC. Consistent with our a priori hypotheses, list learning in our AD sample was characterized by a reduced primacy effect and a relatively spared recency effect; however, recency memory was associated with cerebral metabolism in inferior and lateral temporal regions associated with the semantic memory network, rather than regions associated with short-term verbal memory. The correlates of recognition memory included the medial temporal lobe

  19. Features and applications of positron emission tomography

    International Nuclear Information System (INIS)

    Fan Mingwu

    1997-01-01

    Positron emission tomography, the so-called world's smartest camera, is based on a NaI or BGO detector and imaging of positron-emitting radioisotopes which are introduced as a tracer into the regional tissue or organ of interest. With the aid of a computer visual images of a series of these distributions can be built into a picture of the functional status of the tissue or organ being imaged. This highly accurate imaging technique is already widely used for clinical diagnostics heart disease, brain disorder, tumors and so on

  20. The Norepinephrine Transporter in Attention-Deficit/Hyperactivity Disorder Investigated With Positron Emission Tomography

    Science.gov (United States)

    Rami-Mark, Christina; Savli, Markus; Höflich, Anna; Kranz, Georg S.; Hahn, Andreas; Kutzelnigg, Alexandra; Traub-Weidinger, Tatjana; Mitterhauser, Markus; Wadsak, Wolfgang; Hacker, Marcus; Volkow, Nora D.; Kasper, Siegfried; Lanzenberger, Rupert

    2015-01-01

    IMPORTANCE Attention-deficit/hyperactivity disorder (ADHD) research has long focused on the dopaminergic system’s contribution to pathogenesis, although the results have been inconclusive. However, a case has been made for the involvement of the noradrenergic system, which modulates cognitive processes, such as arousal, working memory, and response inhibition, all of which are typically affected in ADHD. Furthermore, the norepinephrine transporter (NET) is an important target for frequently prescribed medication in ADHD. Therefore, the NET is suggested to play a critical role in ADHD. OBJECTIVE To explore the differences in NET nondisplaceable binding potential (NET BPND) using positron emission tomography and the highly selective radioligand (S,S)-[18F]FMeNER-D2 [(S,S)-2-(α-(2-[18F]fluoro[2H2]methoxyphenoxy)benzyl)morpholine] between adults with ADHD and healthy volunteers serving as controls. DESIGN, SETTING, AND PARTICIPANTS Twenty-two medication-free patients with ADHD (mean [SD] age, 30.7 [10.4] years; 15 [68%] men) without psychiatric comorbidities and 22 age- and sex-matched healthy controls (30.9 [10.6] years; 15 [68%] men) underwent positron emission tomography once. A linear mixed model was used to compare NET BPND between groups. MAIN OUTCOMES AND MEASURES The NET BPND in selected regions of interest relevant for ADHD, including the hippocampus, putamen, pallidum, thalamus, midbrain with pons (comprising a region of interest that includes the locus coeruleus), and cerebellum. In addition, the NET BPND was evaluated in thalamic subnuclei (13 atlas-based regions of interest). RESULTS We found no significant differences in NET availability or regional distribution between patients with ADHD and healthy controls in all investigated brain regions (F1,41 < 0.01; P = .96). Furthermore, we identified no significant association between ADHD symptom severity and regional NET availability. Neither sex nor smoking status influenced NET availability. We determined

  1. Amyloid-β positron emission tomography imaging probes

    DEFF Research Database (Denmark)

    Kepe, Vladimir; Moghbel, Mateen C; Långström, Bengt

    2013-01-01

    , a number of factors appear to preclude these probes from clinical utilization. As the available "amyloid specific" positron emission tomography imaging probes have failed to demonstrate diagnostic value and have shown limited utility for monitoring therapeutic interventions in humans, a debate...

  2. Clinical evaluation of misonidazole combined with radiotherapy in the treatment of carcinoma of the esophagus. A double-blind randomized trial

    Energy Technology Data Exchange (ETDEWEB)

    Irie, Goro (Hokkaido Univ., Sapporo (Japan). School of Medicine); Sakurai, Tomoyasu; Kikuchi, Yuzo

    1984-10-01

    A double-blind trial of misonidazole in esophageal cancer was undertaken from January 1981 to October 1982 as collaborative effort of the department of radiology of 18 institutions. The purposes of this study were: (1) To establish whether misonidazole can increase the effect of radiation in the treatment of patients with inoperable esophageal cancer and (2) to assess the toxic effects of misonidazole. A total 119 patients were enrolled in this study and 104 (misonidazole group : 48 patients, control group : 56 patients) were determined as eligible for evaluation. The patients were randomly allocated into two groups receiving either misonidazole or placebo. The patients were irradiated with 2 Gy/fraction, 5 times a week to a total dose of 40--75 Gy (mostly 60 Gy). 0.5g/m/sup 2/ of misonidazole was given 4 hours before each radiotherapy up to 10g/m/sup 2/. The effect of the treatment was evaluated as a decrease in the volume of the tumors. Histological types of the tumors were squamous cell carcinoma except a case with adenocarcinoma. The distribution of patients according to the stage and tumor type on X-ray images was equivalent in both groups. 85.4% of the patients in the misonidazole group obtained a complete response (CR) or a partial response (PR) as compared to 83.9% in the control group. No difference was demonstrated in the tumor regression comparing the two groups. Four patients in the misonidazole group (8%) developed central or peripheral neuropathy. There have been no severe complications in any of the patients. This study has failed to demonstrate any advantage for the addition of misonidazole in the radiation therapy of esophageal cancer. Possible reasons for the failure to demonstrate any therapeutic gain from misonidazole were discussed.

  3. Positron transaxial emission tomograph with computerized image reconstruction

    International Nuclear Information System (INIS)

    Jatteau, Michel.

    1981-01-01

    This invention concerns a positron transaxial emission tomography apparatus with computerized image reconstruction, like those used in nuclear medicine for studying the metabolism of organs, in physiological examinations and as a diagnosis aid. The operation is based on the principle of the detection of photons emitted when the positrons are annihilated by impact with an electron. The appliance is mainly composed of: (a) - a set of gamma ray detectors distributed on a polygonal arrangement around the body area to be examined, (b) - circuits for amplifying the signals delivered by the gamma ray detectors, (c) - computers essentially comprising energy integration and discrimination circuits and provided at the output of the detectors for calculating and delivering, as from the amplified signals, information on the position and energy relative to each occurrence constituted by the detections of photons, (d) - time coincidence circuits for selecting by emission of detector validation signals, only those occurrences, among the ensemble of those detected, which effectively result from the annihilation of positrons inside the area examined, (e) - a data processing system [fr

  4. Positron emission tomography of the heart

    International Nuclear Information System (INIS)

    Budinger, T.F.; Yano, Y.; Moyer, B.R.; Mathis, C.A.; Ganz, E.; Huesman, R.H.; Derenzo, S.E.

    1982-01-01

    Positron emission tomography (PET) of the heart can measure blood perfusion, metabolism of fatty acids, metabolism of sugars, uptake of amino acids and can quantitate infarction volume. The principles which are basic to PET instrumentation and procedures for quantitative studies of the heart muscle with examples of measurements of myocardial flow and metabolism, are reviewed

  5. Positron emission tomography of the heart

    International Nuclear Information System (INIS)

    Budinger, T.F.; Yano, Y.; Huesman, R.H.; Derenzo, S.E.; Moyer, B.R.; Mathis, C.A.; Ganz, E.; Knittel, B.

    1983-01-01

    Positron emission tomography (PET) of the heart can measure blood perfusion, metabolism of fatty acids, metabolism of sugars, uptake of amino acids and can quantitate infarction volume. The principles are reviewed which are basic to PET instrumentation and procedures for quantitative studies of human physiology with examples of measurements of myocardial flow and metabolism

  6. Positron Emission Tomography (PET) Experience with 2-[18F]Fluoro-3-(2(S)-azetidinylmethoxy)pyridine (2-[18F]FA) in the Living Human Brain of Smokers with Paranoid Schizophrenia

    Science.gov (United States)

    BRAŠIĆ, JAMES ROBERT; CASCELLA, NICOLA; KUMAR, ANIL; ZHOU, YUN; HILTON, JOHN; RAYMONT, VANESSA; CRABB, ANDREW; GUEVARA, MARIA RITA; HORTI, ANDREW G.; WONG, DEAN FOSTER

    2012-01-01

    Utilizing postmortem data (Breese, et al., 2000), we hypothesized that the densities of high-affinity neuronal α4β2 nicotinic acetylcholine receptors (nAChRs) in the brain exist in a continuum from highest to lowest as follows: smokers without schizophrenia > smokers with schizophrenia > nonsmokers without schizophrenia > nonsmokers with schizophrenia. Application of the Kruskal-Wallis Test (Stata, 2003) to the postmortem data (Breese, et al., 2000) confirmed the hypothesized order in the cortex and the hippocampus and attained significance in the caudate and the thalamus. Positron emission tomography (PET) was performed for 60 minutes at 6 hours after the intravenous administration of 444 megabequerels [MBq] (12 mCi) 2-[18F]fluoro-3-(2(S)-azetidinylmethoxy)pyridine (2-[18F]FA), a radiotracer for high-affinity neuronal α4β2 nAChRs, as a bolus plus continuous infusion to 10 adults (7 men and 3 women) (6 smokers including 5 with paranoid schizophrenia and 4 nonsmokers) ranging in age from 22 to 56 years (mean 40.1, standard deviation 13.6). The thalamic nondisplaceable binding potential (BPND) was 1.32 ± 0.19 (mean ± standard deviation) for healthy control nonsmokers; 0.50 ± 0.19 for smokers with paranoid schizophrenia; and 0.51 for the single smoker without paranoid schizophrenia. The thalamic BPNDs of nonsmokers were significantly higher than those of smokers who smoked cigarettes a few hours before the scans (P = 0.0105) (StataCorp, 2003), which was likely due to occupancy of nAChRs by inhaled nicotine in smokers. Further research is needed to rule out the effects of confounding variables. PMID:22169936

  7. Positron Emission Tomography: Principles, Technology, and Recent Developments

    Science.gov (United States)

    Ziegler, Sibylle I.

    2005-04-01

    Positron emission tomography (PET) is a nuclear medical imaging technique for quantitative measurement of physiologic parameters in vivo (an overview of principles and applications can be found in [P.E. Valk, et al., eds. Positron Emission Tomography. Basic Science and Clinical Practice. 2003, Springer: Heidelberg]), based on the detection of small amounts of posi-tron-emitter-labelled biologic molecules. Various radiotracers are available for neuro-logical, cardiological, and oncological applications in the clinic and in research proto-cols. This overview describes the basic principles, technology, and recent develop-ments in PET, followed by a section on the development of a tomograph with ava-lanche photodiodes dedicated for small animal imaging as an example of efforts in the domain of high resolution tomographs.

  8. Cerebral hypometabolism in progressive supranuclear palsy studied with positron emission tomography

    International Nuclear Information System (INIS)

    Foster, N.L.; Gilman, S.; Berent, S.; Morin, E.M.; Brown, M.B.; Koeppe, R.A.

    1988-01-01

    Progressive supranuclear palsy (PSP) is characterized by supranuclear palsy of gaze, axial dystonia, bradykinesia, rigidity, and a progressive dementia. Pathological changes in this disorder are generally restricted to subcortical structures, yet the type and range of cognitive deficits suggest the involvement of many cerebral regions. We examined the extent of functional impairment to cerebral cortical and subcortical structures as measured by the level of glucose metabolic activity at rest. Fourteen patients with PSP were compared to 21 normal volunteers of similar age using 18F-2-fluoro-2-deoxy-D-glucose and positron emission tomography. Glucose metabolism was reduced in the caudate nucleus, putamen, thalamus, pons, and cerebral cortex, but not in the cerebellum in the patients with PSP as compared to the normal subjects. Analysis of individual brain regions revealed significant declines in cerebral glucose utilization in most regions throughout the cerebral cortex, particularly those in the superior half of the frontal lobe. Declines in the most affected regions of cerebral cortex were greater than those in any single subcortical structure. Although using conventional neuropathological techniques the cerebral cortex appears to be unaffected in PSP, significant and pervasive functional impairments in both cortical and subcortical structures are present. These observations help to account for the constellation of cognitive symptoms in individual patients with PSP and the difficulty encountered in identifying a characteristic psychometric profile for this group of patients

  9. 18F-FDG positron emission tomography/computed tomography in infective endocarditis.

    Science.gov (United States)

    Salomäki, Soile Pauliina; Saraste, Antti; Kemppainen, Jukka; Bax, Jeroen J; Knuuti, Juhani; Nuutila, Pirjo; Seppänen, Marko; Roivainen, Anne; Airaksinen, Juhani; Pirilä, Laura; Oksi, Jarmo; Hohenthal, Ulla

    2017-02-01

    The diagnosis of infective endocarditis (IE), especially the diagnosis of prosthetic valve endocarditis (PVE) is challenging since echocardiographic findings are often scarce in the early phase of the disease. We studied the use of 2-[ 18 F]fluoro-2-deoxy-D-glucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) in IE. Sixteen patients with suspected PVE and 7 patients with NVE underwent visual evaluation of 18 F-FDG-PET/CT. 18 F-FDG uptake was measured also semiquantitatively as maximum standardized uptake value (SUV max ) and target-to-background ratio (TBR). The modified Duke criteria were used as a reference. There was strong, focal 18 F-FDG uptake in the area of the affected valve in all 6 cases of definite PVE, in 3 of 5 possible PVE cases, and in 2 of 5 rejected cases. In all patients with definite PVE, SUV max of the affected valve was higher than 4 and TBR higher than 1.8. In contrast to PVE, only 1 of 7 patients with NVE had uptake of 18 F-FDG by PET/CT in the valve area. Embolic infectious foci were detected in 58% of the patients with definite IE. 18 F-FDG-PET/CT appears to be a sensitive method for the detection of paravalvular infection associated with PVE. Instead, the sensitivity of PET/CT is limited in NVE.

  10. Positron Emission Tomography Reveals Abnormal Topological Organization in Functional Brain Network in Diabetic Patients.

    Science.gov (United States)

    Qiu, Xiangzhe; Zhang, Yanjun; Feng, Hongbo; Jiang, Donglang

    2016-01-01

    Recent studies have demonstrated alterations in the topological organization of structural brain networks in diabetes mellitus (DM). However, the DM-related changes in the topological properties in functional brain networks are unexplored so far. We therefore used fluoro-D-glucose positron emission tomography (FDG-PET) data to construct functional brain networks of 73 DM patients and 91 sex- and age-matched normal controls (NCs), followed by a graph theoretical analysis. We found that both DM patients and NCs had a small-world topology in functional brain network. In comparison to the NC group, the DM group was found to have significantly lower small-world index, lower normalized clustering coefficients and higher normalized characteristic path length. Moreover, for diabetic patients, the nodal centrality was significantly reduced in the right rectus, the right cuneus, the left middle occipital gyrus, and the left postcentral gyrus, and it was significantly increased in the orbitofrontal region of the left middle frontal gyrus, the left olfactory region, and the right paracentral lobule. Our results demonstrated that the diabetic brain was associated with disrupted topological organization in the functional PET network, thus providing functional evidence for the abnormalities of brain networks in DM.

  11. Effect of ginseng pretreatment on cerebral glucose metabolism in ischaemic rats using animal positron emission tomography (PET) and [18F]-FDG

    Energy Technology Data Exchange (ETDEWEB)

    Rye, Choi Seok; Magata, Y.; Saji, H.; Tajima, K.; Kitano, H.; Konishi, J.; Yokoyama, A. [Department of Radiopharmaceutical Chemistry, Faculty of Pharmaceutical Sciences, Kyoto University, Yoshida Shimoadachi-cho, Sakyo-ku, Kyoto 606-01 (Japan)

    1997-07-01

    To investigate the effect of ginseng on damaged brain activity, we evaluated the cerebral metabolic rate of glucose (CMRglc) as a functional index in post-ischaemic rats and compared the results with those obtained after the administration of a ginseng extract. CMRglc was measured using high resolution animal positron emission tomography with {sup 18}F-2-fluoro-2-deoxy-D-glucose ({sup 18}F-FDG). The rats subjected to a 30-min occlusion showed a significant reduction of k3, the rate constant for phosphorylation of {sup 18}F-FDG by hexokinase, compared with the normal value. The ginseng pretreatment prevented the reduction in k3 and CMRglc caused by ischaemia. Although further investigation is needed to elucidate the mechanism of action, ginseng may be useful for prevention and treatment of ischaemia. © 1997 John Wiley & Sons, Ltd.

  12. Somatosensory deficits in monkeys treated with misonidazole

    International Nuclear Information System (INIS)

    Maurissen, J.P.J.; Conroy, P.J.; Passalacqua, W.; Von Burg, R.; Weiss, B.; Sutherland, R.M.

    1981-01-01

    Misonidazole, a hypoxic cell radiosensitizer, can produce peripheral sensory disorders in humans. It has been studied in monkeys with a computer-controlled system for evaluating vibration sensitivity. Monkeys were trained to report when vibration was stimulating the finger tip. Sinusoidal vibrations of several frequencies were presented. Two monkeys were dosed with misonidazole and their vibration sensitivity tested. They received a dose of 3 g/m 2 (about 180 mg/kg) twice weekly over a period of 6 to 10 weeks. An amplitude-frequency detection function was determined for each monkey before and after drug treatment. An analysis of covariance comparing polynomial regressions was performed. A significant difference (p < 0.001) was found between control and experimental curves in both monkeys. Pharmacokinetic data indicated a half-life of the drug in blood of about 4 to 5 hr. The overall half-life for elimination did not increase throughout prolonged treatment with msonidazole. Neither motor nor sensory nerve conduction velocity was reduced after treatment

  13. Nuclear medicine and positron emission tomography: An overview

    International Nuclear Information System (INIS)

    McCarthy, T.J.; Schwarz, S.W.; Welch, M.J.

    1994-01-01

    Nuclear medicine is the field of medical practice that involves the oral or intravenous administration of radioactive materials for use in diagnosis and therapy. The majority of radiopharmaceutical available are used for diagnostic purposes. These involve the determination of organ function, shape, or position from an image of the radioactivity distribution within an organ or at a location within the body. After administration, the radiopharmaceutical localizes within an organ or target tissue due to its biological or physiologic characteristics. This diagnostic capability is usually the result of the emission of gamma radiation from the radiopharmaceutical localized within an organ. This allows for external detection and imaging using a special type of camera known as a gamma camera. When a positron-emitting radionuclide decays, a positron (positive electron) is emitted from the nucleus. The positron then annihilates with an electron, resulting in the release of energy in the form of two 511-KeV γ-rays at 180 degree to one another. The energy of these photons is sufficient to pass through tissue. Thus, placing a series of detectors around the patient allows technicians to monitor the emission of both of the photons that result from a single positron annihilation. this ultimately allows an accurate quantification of the distribution of radioactivity in the body not possible when only a single γ-ray is emitted

  14. New detector developments for high resolution positron emission tomography

    International Nuclear Information System (INIS)

    Ziegler, S.I.; Pichler, B.; Lorenz, E.

    1998-01-01

    The strength of quantitative, functional imaging using positron emission tomography, specially in small animals, is limited due to the spatial resolution. Therefore, various tomograph designs employing new scintillators, light sensors, or coincidence electronic are investigated to improve resolution without losses in sensitivity. Luminous scintillators with short light decay time in combination with novel readout schemes using photomultipliers or semiconductor detectors are currently tested by several groups and are implemented in tomographs for small animals. This review summarises the state of development in high resolution positron emission tomography with a detailed description of a system incorporating avalanche photodiode arrays and small scintillation crystals. (orig.) [de

  15. Positron emission tomography/computed tomography scanning for ...

    African Journals Online (AJOL)

    Background: Although the site of nosocomial sepsis in the critically ill ventilated patient is usually identifiable, it may remain occult, despite numerous investigations. The rapid results and precise anatomical location of the septic source using positron emission tomography (PET) scanning, in combination with computed ...

  16. Evaluation of outcome prediction and disease extension by quantitative 2-deoxy-2-[18F] fluoro-D-glucose with positron emission tomography in patients with small cell lung cancer

    International Nuclear Information System (INIS)

    Arslan, N.; Tuncel, M.; Kuzhan, O.; Alagoz, E.; Budakoglu, B.; Ozet, A.; Ozguven, M.A.

    2011-01-01

    The objective of this study is to determine whether 2-deoxy-2-[18F] fluoro-D-glucose with positron emission tomography (FDG-PET) imaging and quantitative PET parameters can predict outcome and differentiate patients with limited disease (LD) from extensive disease (ED) in patients with small cell lung cancer (SCLC). We retrospectively evaluated data from 25 patients who underwent either initial staging (Group A, n 12) or restaging (Group B, n 13) by conventional imaging methods and FDG-PET according to the simplified staging scheme developed by the Veterans Administration Lung Cancer Study Group-2. FDG-PET images were both visually and quantitatively evaluated with standardized uptake value (SUV) max , SUV ave , total metabolic tumor volume (with SUV max >%50 and SUV max >2.5), total lesion glycolysis (TLG) (with SUV max >%50 and SUV max >2.5). The correlation between quantitative PET parameters, disease stages and survival were analyzed. By conventional methods 14 of 25 (56%) patients were reported to have LD and 11 of 25 (44%) had ED. FDG-PET scan upstaged 9 out of 25 (36%) and downstaged 2 out of 25 (%8) patients. Among the quantitative PET parameters, TLGs were the only PET parameters that differentiated between Group A and Group B patients. FDG-PET staging (p=0.019) could predict significant survival difference between stages on contrary to conventional staging (p=0.055). Moreover, TLG [SUV max >%50] was the only quantitative PET parameter that could predict survival (p=0.027). FDG-PET imaging is a valuable tool in the management of patients with SCLC for a more accurate staging. The use of quantitative PET parameters may have a role in prediction of stage and survival. (author)

  17. 76 FR 6143 - Draft Guidance on Positron Emission Tomography Drug Applications-Content and Format for New Drug...

    Science.gov (United States)

    2011-02-03

    ...; formerly Docket No. 00D-0892] Draft Guidance on Positron Emission Tomography Drug Applications--Content and... Applications for Certain Positron Emission Tomography Drug Products; Availability,'' issued on March 10, 2000... and ANDAs.'' The draft guidance is intended to assist manufacturers of certain positron emission...

  18. Physical and technical basis of positron emission tomography (PET)

    International Nuclear Information System (INIS)

    Bauer, R.

    1994-01-01

    Positron emission tomography utilizes the annihilation of positrons, generating pairs of gamma quanta which are emitted in opposing directions. 'Electronic collimation' is performed by coincident detection of both quanta. Thus, there is no need for mechanical collimators and no limiting connection between sensitivity and spatial resolution. Transversal tomograms are reconstructed from the projection data by means of highly sophisticated data processing. The half life of the most positron emitters used in medical applications is short and of the order of some minutes. Therefore, many positron emitters have to be produced on-side by means of a cyclotron. PET is superior to SPECT with respect to physical and technical aspects, but the high costs of PET limit its wide-spread use up to now. (orig.) [de

  19. Role of fluorine-18-labeled 2-fluoro-2-deoxy-D-glucose positron emission tomography-computed tomography in the evaluation of axillary lymph node involvement in operable breast cancer in comparison with sentinel lymph node biopsy

    International Nuclear Information System (INIS)

    Challa, Vasu Reddy; Srivastava, Anurag; Dhar, Anita; Parshad, Rajinder; Bal, Chandrasekhar; Gona, Rama Mohan Reddy; Kumar, Rakesh; Sharma, Punit; Gupta, Siddhartha Datta

    2013-01-01

    Role of (18(F)fluorine-18-labeled 2-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography-computed tomography (PET-CT) in the evaluation of axillary lymph node involvement in T1T2N0 breast cancer and compare results with sentinel lymph node biopsy (SLNB). SLN was identified in 32 of 37 patients with an identification rate of 86.48% (32/37). With combined technique SLN identification rate was 100% (6/6) while with blue dye alone; it was 83.8% (26/31). Among 37 patients, 16 had axillary metastases of which 12 had macrometastases and four had micrometastases detected by immunohistochemistry (IHC). Of 12 patients with axillary macrometastases, skip metastases were present in two patients in whom SLN was negative and in two patients SLN was not identified, but axillary dissection showed metastases. PET-CT had shown sensitivity, specificity, negative predictive value and positive predictive value of 56%, 90%, 73%, and 81.8%, respectively. IHC of SLN detected four patients with micrometastases upstaging the disease by 11% (4/37). Because FDG PET-CT has a high specificity in the evaluation of axillary lymph node involvement in T1T2N0 breast cancer patients according to the results of this study if FDG PET-CT is positive in axillary lymph nodes, axillary lymph node dissection may be considered instead of SLNB

  20. Scintillation crystals for positron emission tomography having a non reflecting band

    International Nuclear Information System (INIS)

    Thompson, C.J.

    1992-01-01

    This invention relates generally to positron emission tomography, a sub-field of the class of medical imaging techniques using ionizing radiation and image reconstruction techniques; and more particularly to devices which use an array of scintillation detectors to detect the annihilation radiation from positron disintegration and use this information to reconstruct an image of the distribution of positron emitting isotope within a body section. 6 figs

  1. Is positron emission tomography useful in stroke?

    NARCIS (Netherlands)

    DeReuck, J; Leys, D; DeKeyser, J

    Positron emission tomography (PET) has been widely used in the study of stroke and related cerebrovascular diseases. It has shown the various stages leading to cerebral infarction and defined the significance of the ischaemic penumbra. PET scan can predict the clinical outcome of patients with acute

  2. Positron emission tomography in malignant haematological disease

    NARCIS (Netherlands)

    Schot, Bartholomeus Wilhelmus

    2007-01-01

    Positron emission tomography (PET) is a diagnostic technique with a promising role especially in the haemato-oncology. Although its use in the management ; of malignant lymphoma seems to be established already, much about the true potential and drawbacks of FDG-PET in this disease are still unknown.

  3. Evaluation of scintillators and semiconductor detectors to image three-photon positron annihilation for positron emission tomography

    International Nuclear Information System (INIS)

    Abuelhia, E.; Spyrou, N.M.; Kacperski, K.; College University, Middlesex Hospital, London

    2008-01-01

    Positron emission tomography (PET) is rapidly becoming the main nuclear imaging modality of the present century. The future of PET instrumentation relies on semiconductor detectors because of their excellent characteristics. Three-photon positron annihilation has been recently investigated as a novel imaging modality, which demands the crucial high energy resolution of semiconductor detector. In this work the evaluation of the NaI(Tl) scintillator and HPGe and CdZTe semiconductor detectors, to construct a simple three-photon positron annihilation scanner has been explored. The effect of detector and scanner size on spatial resolution (FWHM) is discussed. The characteristics: energy resolution versus count rate and point-spread function of the three-photon positron annihilation image profile from triple coincidence measurements were investigated. (author)

  4. Positron emission tomographic imaging of tumors using monoclonal antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Zalutsky, M.R.

    1992-08-01

    This research project is developing methods for utilizing positron emission tomography (PET) to increase the clinical potential of radiolabeled monoclonal antibodies (MAbs). This report describes the development of methods for labeling MAbs and their fragments with positron-emitting halogen nuclides, fluorine-18 and iodine-124. These nulides were selected because of the widespread availability of F-18 and because of our extensive experience in the development of new protein radiohalogenation methods.

  5. Positron emission tomography in a national research centre

    International Nuclear Information System (INIS)

    Weinreich, R.

    1989-01-01

    The example of the Paul Scherrer Institute shows that positron emission tomography can be implanted successfully as spin-off into an appropriate environment. The adaption to the existing irradiation facilities of the technique of production of the short-lived positron emitters is complex. However, the basic necessities of a tomography programme can be covered. Moreover, the relatively high energy of the institute's injector cyclotron allows additional production of rare-used longer-lived positron emitters. The scanner exceeded the guaranteed specifications. With respect to the somewhat lower availability of beam time compared to a usual baby cyclotron, the research programme must not be very patient-intense. A strong participation of the pharmaceutical industry has directed research priorities into the pharmacological area. (orig.) [de

  6. Positron emission tomography applied to fluidization engineering

    NARCIS (Netherlands)

    Dechsiri, C; Ghione, A; van de Wiel, F; Dehling, HG; Paans, AMJ; Hoffmann, AC

    The movement of particles in a laboratory fluidized bed has been studied using Positron Emission Tomography (PET). With this non-invasive technique both pulses of various shapes and single tracer particles were followed in 3-D. The equipment and materials used made it possible to label actual bed

  7. Clinical experience with intravenous misonidazole for carcinoma of the esophagus: results in attempting radiosensitization of each fraction of exposure

    International Nuclear Information System (INIS)

    Schwade, J.G.; Kinsella, T.J.; Kelly, B.; Rowland, J.; Johnston, M.; Glatstein, E.

    1984-01-01

    By using intravenous misonidazole, a hypoxic cell radiosensitizer, the authors attempted to test the hypothesis of hypoxia as the basis of the relatively poor results seen with radiation therapy in the treatment of carcinoma of the thoracic esophagus. As the peripheral neuropathy of misonidazole was well recognized, they felt that an adequate dose of misonidazole could be given approximately ten times before peripheral neuropathy would necessitate its discontinuation. Because of a desire to maximize any possible effects of radiosensitization, it was decided to administer misonidazole with each fraction of radiation, attempting to deliver curative radiation therapy with only ten fractions of radiation. The authors thus devised a scheme of radiation consisting of 400 rad twice a week for 5 weeks, a total of 4000 rad. Originally the attempt was made to utilize preoperative radiation therapy and assess the histologic specimens for efficacy. However, major pulmonary toxicity caused revision of that plan. Twenty six patients were treated with radiotherapy alone without surgery, 12 of the patients being randomized to receive intravenous misonidazole with 10 fractions of 400 rad each. In terms of partial response, complete response, local control, and long-term survival, there was no suggestion of any benefit of intravenous misonidazole in these patients. As a consequence, although the number of study patients was small, the investigation was discontinued. Possible explanations for the failure to demonstrate any benefit of misonidazole are discussed

  8. Positron Emission Tomography Particle tracking using cluster analysis

    International Nuclear Information System (INIS)

    Gundogdu, O.

    2004-01-01

    Positron Emission Particle Tracking was successfully used in a wide range of industrial applications. This technique primarily uses a single positron emitting tracer particle. However, using multiple particles would provide more comparative information about the physical processes taking place in a system such as mixing or fluidised beds. In this paper, a unique method that enables us to track more than one particle is presented. This method is based on the midpoint of the closest distance between two trajectories or coincidence vectors. The technique presented in this paper employs a clustering method

  9. Positron Emission Tomography Particle tracking using cluster analysis

    Energy Technology Data Exchange (ETDEWEB)

    Gundogdu, O. [University of Birmingham, School of Physics and Astronomy, Birmingham, B15 2TT (United Kingdom)]. E-mail: o.gundogdu@surrey.ac.uk

    2004-12-01

    Positron Emission Particle Tracking was successfully used in a wide range of industrial applications. This technique primarily uses a single positron emitting tracer particle. However, using multiple particles would provide more comparative information about the physical processes taking place in a system such as mixing or fluidised beds. In this paper, a unique method that enables us to track more than one particle is presented. This method is based on the midpoint of the closest distance between two trajectories or coincidence vectors. The technique presented in this paper employs a clustering method.

  10. 77 FR 71802 - Guidance on Investigational New Drug Applications for Positron Emission Tomography Drugs...

    Science.gov (United States)

    2012-12-04

    ... Positron Emission Tomography (PET) Drugs.'' The guidance is intended to assist manufacturers of PET drugs... one self-addressed adhesive label to assist that office in processing your requests. See the... ``Investigational New Drug Applications for Positron Emission Tomography (PET) Drugs.'' The guidance summarizes the...

  11. Cholinergic Receptor Binding in Alzheimer Disease and Healthy Aging: Assessment In Vivo with Positron Emission Tomography Imaging.

    Science.gov (United States)

    Sultzer, David L; Melrose, Rebecca J; Riskin-Jones, Hannah; Narvaez, Theresa A; Veliz, Joseph; Ando, Timothy K; Juarez, Kevin O; Harwood, Dylan G; Brody, Arthur L; Mandelkern, Mark A

    2017-04-01

    To compare regional nicotinic cholinergic receptor binding in older adults with Alzheimer disease (AD) and healthy older adults in vivo and to assess relationships between receptor binding and clinical symptoms. Using cross-sectional positron emission tomography (PET) neuroimaging and structured clinical assessment, outpatients with mild to moderate AD (N = 24) and healthy older adults without cognitive complaints (C group; N = 22) were studied. PET imaging of α4β2* nicotinic cholinergic receptor binding using 2-[ 18 F]fluoro-3-(2(S)azetidinylmethoxy)pyridine (2FA) and clinical measures of global cognition, attention/processing speed, verbal memory, visuospatial memory, and neuropsychiatric symptoms were used. 2FA binding was lower in the AD group compared with the C group in the medial thalamus, medial temporal cortex, anterior cingulate, insula/opercula, inferior caudate, and brainstem (p healthy older adults, lower receptor binding may be associated with slower processing speed. Cholinergic receptor binding in vivo may reveal links to other key brain changes associated with aging and AD and may provide a potential molecular treatment target. Published by Elsevier Inc.

  12. A simulation study of a method to reduce positron annihilation spread distributions using a strong magnetic field in positron emission tomography

    International Nuclear Information System (INIS)

    Iida, H.; Kanno, I.; Miura, S.; Murakami, M.; Takahashi, V.; Kemura, K.

    1986-01-01

    The positron trajectories have been three-dimensionally simulated using a Monte-Carlo method under various strength of the magnetic field. More than 5 tesla of the field confined the positrons effectively, resulting in increase of the probability of the annihilation within a limited small region, hence the higher spatial resolution in positron emission tomography

  13. Overeating Behavior and Striatal Dopamine with 6-[18F]-Fluoro-L--Tyrosine PET

    Directory of Open Access Journals (Sweden)

    Claire E. Wilcox

    2010-01-01

    Full Text Available Eating behavior may be affected by dopamine synthesis capacity. In this study, 6-[18F]-fluoro-L--tyrosine (FMT positron emission tomography (PET uptake in striatal subregions was correlated with BMI (kg/m2 and an estimate of the frequency of prior weight loss attempts in 15 healthy subjects. BMI was negatively correlated with FMT uptake in the dorsal caudate. Although the association between BMI and FMT uptake in the dorsal caudate was not significant upon correction for age and sex, the association fell within the range of a statistical trend. Weight loss attempts divided by years trying was also negatively correlated with FMT uptake in the dorsal putamen (=.05. These results suggest an association between low dorsal striatal presynaptic dopamine synthesis capacity and overeating behavior.

  14. Positron Emission Tomography (PET)

    International Nuclear Information System (INIS)

    Welch, M.J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET. 22 figs

  15. Positron Emission Tomography (PET)

    Science.gov (United States)

    Welch, M. J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET.

  16. Positron Emission Tomography (PET)

    Energy Technology Data Exchange (ETDEWEB)

    Welch, M.J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET. 22 figs.

  17. The effect of dynamic knee-extension exercise on patellar tendon and quadriceps femoris muscle glucose uptake in humans studied by positron emission tomography

    DEFF Research Database (Denmark)

    Kalliokoski, Kari K; Langberg, Henning; Ryberg, Ann Kathrine

    2005-01-01

    Both tendon and peritendinous tissue show evidence of metabolic activity, but the effect of acute exercise on substrate turnover is unknown. We therefore examined the influence of acute exercise on glucose uptake in the patellar and quadriceps tendons during dynamic exercise in humans. Glucose...... that tendon glucose uptake is increased during exercise. However, the increase in tendon glucose uptake is less pronounced than in muscle and the increases are uncorrelated. Thus tendon glucose uptake is likely to be regulated by mechanisms independently of those regulating skeletal muscle glucose uptake....... uptake was measured in five healthy men in the patellar and quadriceps tendons and the quadriceps femoris muscle at rest and during dynamic knee-extension exercise (25 W) using positron emission tomography and [18F]-2-fluoro-2-deoxy-D-glucose ([18F]FDG). Glucose uptake index was calculated by dividing...

  18. Fluorine-18 deoxyglucose uptake in sarcoidosis measured with positron emission tomography

    International Nuclear Information System (INIS)

    Brudin, L.H.; Valind, S.O.; Rhodes, C.G.; Pantin, C.F.; Sweatman, M.; Jones, T.; Hughes, J.M.B.

    1994-01-01

    Regional pulmonary glucose metabolism (MR glu ; μmol h -1 g -1 ), extravascular lung density (D EV ; g cm -3 ) and vascular volume (V B ; ml cm -3 ) were measured in a single midthoracic transaxial slice (-2 cm thick) using positron emission tomography (PET) in seven patients with histologically proven sarcoidosis. The measurements were repeated 1-7 months later after steroid therapy (in two cases, no treatment) in order to assess MR glu as an index of inflammation and relate it to routine pulmonary function tests, chest radiography and serum angiotensin converting enzyme (SACE) levels. MR glu was computed from serial lung scans and peripheral venous blood samples for 60 min following an i.v. injection of 18 F-2-fluoro-2-deoxy-D-glucose ( 18 FDG). Both MR glu (which was increased in six of seven patients) and elevated SACE levels returned to normal in those patients treated with high-dose steroids. Regional vascular volume was normal in six of seven cases and did not change significantly with therapy. The high tissue density measured in all patients decreased significantly in two of three patients treated with 40 mg prednisolone daily. The abnormal MR glu observed in active sarcoidosis becomes normal pari passu with SACE levels during high-dose steroid therapy. We conclude that MR glu measured with 18 FDG and PET may reflect ''disease activity'' in sarcoidosis in quantitative terms (per gram lung tissue) and in respect of disease distribution. (orig.)

  19. Advanced Instrumentation for Positron Emission Tomography [PET

    Science.gov (United States)

    Derenzo, S. E.; Budinger, T. F.

    1985-04-01

    This paper summarizes the physical processes and medical science goals that underlay modern instrumentation design for Positron Emission Tomography. The paper discusses design factors such as detector material, crystalphototube coupling, shielding geometry, sampling motion, electronics design, time-of-flight, and the interrelationships with quantitative accuracy, spatial resolution, temporal resolution, maximum data rates, and cost.

  20. An analysis of true- and false-positive results of vocal fold uptake in positron emission tomography-computed tomography imaging.

    Science.gov (United States)

    Seymour, N; Burkill, G; Harries, M

    2018-03-01

    Positron emission tomography-computed tomography with fluorine-18 fluorodeoxy-D-glucose has a major role in the investigation of head and neck cancers. Fluorine-18 fluorodeoxy-D-glucose is not a tumour-specific tracer and can also accumulate in benign pathology. Therefore, positron emission tomography-computed tomography scan interpretation difficulties are common in the head and neck, which can produce false-positive results. This study aimed to investigate patients detected as having abnormal vocal fold uptake on fluorine-18 fluorodeoxy-D-glucose positron emission tomography-computed tomography. Positron emission tomography-computed tomography scans were identified over a 15-month period where reports contained evidence of unilateral vocal fold uptake or vocal fold pathology. Patients' notes and laryngoscopy results were analysed. Forty-six patients were identified as having abnormal vocal fold uptake on positron emission tomography-computed tomography. Twenty-three patients underwent positron emission tomography-computed tomography and flexible laryngoscopy: 61 per cent of patients had true-positive positron emission tomography-computed tomography scans and 39 per cent had false-positive scan results. Most patients referred to ENT for abnormal findings on positron emission tomography-computed tomography scans had true-positive findings. Asymmetrical fluorine-18 fluorodeoxy-D-glucose uptake should raise suspicion of vocal fold pathology, accepting a false-positive rate of approximately 40 per cent.

  1. Serotonin synthesis studied with positron emission tomography, (PET)

    DEFF Research Database (Denmark)

    Honoré, Per Gustaf Hartvig; Lundquist, Pinelopi

    Positron emission tomography (PET) has the potential to study the biosynthesis and release of serotonin (5HT) at brain serotonergic neurons. PET requires probe compounds with specific attributes to enable imaging and quantification of biological processes. This section focuses on probes to measure...

  2. Positron emission CT on post-traumatic epilepsy

    International Nuclear Information System (INIS)

    Tsukiyama, Takashi; Tsubokawa, Takashi; Doi, Nobuyasu; Sato, Kohten; Iio, Masaaki.

    1983-01-01

    Six patients suffering from post-traumatic epilepsy were checked by encephalography (EEG), X-ray CT and cerebral positron emission computed tomography (PECT) using 11 C-carbon dioxide ( 11 CO 2 ) and 11 C-glucoses as indicators of the local cerebral circulation and local cerebral glucose utilization, in order to assess the diagnostic value of PECT in post-traumatic epilepsy. In those patients (4 cases) who had focal electrical abnormalities or X-ray CT lesions, PECT clearly revealed localized regions of decreased cerebral circulation and glucose utilization. A focal hypometabolic zone also appeared in the post-traumatic epilepsy (1 case) which had a normal X-ray CT. One case, who had been treated for several years by medication but showed no EEG change and no abnormality on X-ray CT, revealed a normal circulation and metabolism by RECT. This case did not require any further medication for epilepsy. It is concluded that positron emission CT represents a useful diagnostic method for post-traumatic epilepsy which does not demonstrate any abnormality on X-ray CT. (author)

  3. Comparison of Positron Emission Tomography Using 2-[18F]-fluoro-2-deoxy-D-glucose and 3-deoxy-3-[18F]-fluorothymidine in Lung Cancer Imaging

    Science.gov (United States)

    Wang, Fu-Li; Tan, Ye-Ying; Gu, Xiang-Min; Li, Tian-Ran; Lu, Guang-Ming; Liu, Gang; Huo, Tian-Long

    2016-01-01

    Background: The detection of solitary pulmonary nodules (SPNs) that may potentially develop into a malignant lesion is essential for early clinical interventions. However, grading classification based on computed tomography (CT) imaging results remains a significant challenge. The 2-[18F]-fluoro-2-deoxy-D-glucose (18F-FDG) positron emission tomography (PET)/CT imaging produces both false-positive and false-negative findings for the diagnosis of SPNs. In this study, we compared 18F-FDG and 3-deoxy-3-[18F]-fluorothymidine (18F-FLT) in lung cancer PET/CT imaging. Methods: The binding ratios of the two tracers to A549 lung cancer cells were calculated. The mouse lung cancer model was established (n = 12), and micro-PET/CT analysis using the two tracers was performed. Images using the two tracers were collected from 55 lung cancer patients with SPNs. The correlation among the cell-tracer binding ratios, standardized uptake values (SUVs), and Ki-67 proliferation marker expression were investigated. Results: The cell-tracer binding ratio for the A549 cells using the 18F-FDG was greater than the ratio using 18F-FLT (P < 0.05). The Ki-67 expression showed a significant positive correlation with the 18F-FLT binding ratio (r = 0.824, P < 0.01). The tumor-to-nontumor uptake ratio of 18F-FDG imaging in xenografts was higher than that of 18F-FLT imaging. The diagnostic sensitivity, specificity, and the accuracy of 18F-FDG for lung cancer were 89%, 67%, and 73%, respectively. Moreover, the diagnostic sensitivity, specificity, and the accuracy of 18F-FLT for lung cancer were 71%, 79%, and 76%, respectively. There was an obvious positive correlation between the lung cancer Ki-67 expression and the mean maximum SUV of 18F-FDG and 18F-FLT (r = 0.658, P < 0.05 and r = 0.724, P < 0.01, respectively). Conclusions: The 18F-FDG uptake ratio is higher than that of 18F-FLT in A549 cells at the cellular level. 18F-FLT imaging might be superior for the quantitative diagnosis of lung tumor

  4. Decision logic for retreatment of asymptomatic lung cancer recurrence based on positron emission tomography findings

    International Nuclear Information System (INIS)

    Frank, Albert; Lefkowitz, David; Jaeger, Stanley; Gobar, Lisa; Sunderland, John; Gupta, Naresh; Scott, Walter; Mailliard, James; Lynch, Henry; Bishop, John; Thorpe, Patricia; Dewan, Naresh

    1995-01-01

    Purpose: The purpose of the study was to determine if Positron emission tomography (PET) 2-[F-18] fluoro-2-deoxy-D-glucose (FDG) imaging could detect subclinical local lung cancer recurrence and whether retreatment of such recurrence was feasible and beneficial. Methods and Materials: Twenty patients with biopsy proven lung cancer were studied with Positron emission tomography for the purpose of detecting subclinical lung cancer recurrence over a period of 4.25 years. All patients were treated with external radiation as part or all of their therapy. Twenty patients had baseline PET and computed tomography (CT) studies for comparison with later studies. Surviving patients had a total of 40 sequential PET scans and 35 CT scans. The follow-up interval ranged from 5 to 40 months posttreatment. The differential uptake ratio (DUR) was determined for regions of interest of increased FDG uptake. Results: The median DUR value of the 20 baseline PET studies was 5.59. The DUR value of greater than 3 was empirically selected as being positive for tumor detection. On baseline studies, PET had a 100% correlation with the CT findings in regard to detection of the site of primary tumor involvement. Four of 20 patients showed areas of discordance in the mediastinal and hilar areas on initial PET and CT studies. Seven of 17 patients showed discordant posttreatment PET-CT findings. Two false positive PET studies were due to radiation pneumonitis and one to macrophage glycolysis in tumor necrosis. For detection of asymptomatic tumor recurrence, analysis of sequential PET and CT studies, biopsy results, and the patient's clinical course suggested that PET had a sensitivity of 100%, specificity of 89.3%, and accuracy of 92.5%. Computerized Tomography was found to have a sensitivity of 67%, specificity of 85%, and accuracy of 82% for detection of such early-stage recurrence. Five patients went on to have retreatment with external irradiation based upon the PET evidence. Four retreated

  5. Positron emission tomography in brain function study

    International Nuclear Information System (INIS)

    Wu Hua

    2006-01-01

    Little has been recognized about the advanced brain function. Recent years several new techniques such as event-related potentials, megnetoencephalography, functional magnetic resonance imaging and positron emission tomography (PET) have been used in the study of brain function. The methodology, application study in normal people and clinical patients of PET in brain function are reviewed. (authors)

  6. Positron Emission Tomography Reveals Abnormal Topological Organization in Functional Brain Network in Diabetic Patients

    Directory of Open Access Journals (Sweden)

    Qiu eXiangzhe

    2016-05-01

    Full Text Available Recent studies have demonstrated alterations in the topological organization of structural brain networks in diabetes mellitus (DM. However, the DM-related changes in the topological properties in functional brain networks are almost unexplored so far. We therefore used fluoro-D-glucose positron emission tomography (FDG-PET data to construct functional brain networks of 73 DM patients and 91 sex- and age-matched normal controls (NCs, followed by a graph theoretical analysis. We found that both DM patients and NCs had a small-world topology in functional brain network. In comparison to the NC group, the DM group was found to have significantly lower small-world index, lower normalized clustering coefficients and higher normalized shortest path length. Moreover, for diabetic patients, the nodal centrality was significantly reduced in the right rectus, the right cuneus, the left middle occipital gyrus, and the left postcentral gyrus, and it was significantly increased in the orbitofrontal region of the left middle frontal gyrus, the left olfactory region, and the right paracentral lobule. Our results demonstrated that the diabetic brain was associated with disrupted topological organization in the functional PET network, thus providing the functional evidence for the abnormalities of brain networks in DM.

  7. Positron emission tomography: a new paradigm in cancer management

    International Nuclear Information System (INIS)

    Paez Gutierrez, Diana Isabel; De los Reyes, Amelia; Llamas Olier, Augusto

    2007-01-01

    The National Cancer Institute (NCI) is currently building a positron emission tomography facility that will house a cyclotron and a PET fusion scanner. lt should be operational as of december 2007, being a cancer dedicated national referral center, the NCI should provide both positron-emitting radiopharmaceuticals and medical services to institutions and patients nationwide. PET technology provides metabolic information that has been documented to be useful in patient care. The properties of positron decay allow accurate imaging of the in vivo distribution of positron-emitting radiopharmaceuticals. a wide array of positron-emitting radiopharmaceuticals has been used to characterize multiple physiologic and pathologic states. The major clinical PET applications are in cancer patients using fluorine-18 fluorodeoxyglucose (FDG). FDG, an analogue of glucose, accumulates in most tumors in a greater amount than it does in normal tissue. PET is being used in diagnosis and follow-up of several malignancies, and the list of articles supporting its use continues to grow. in this article, the instrumentation aspects of PET are described and most of the clinical applications in oncology are described

  8. Positron emission tomography in movement disorders

    International Nuclear Information System (INIS)

    Martin, W.R.W.

    1985-01-01

    Positron emission tomography provides a method for the quantitation of regional function within the living human brain. Studies of cerebral metabolism and blood flow in patients with Huntington's disease, Parkinson's disease and focal dystonia have revealed functional abnormalities within substructures of the basal ganglia. Recent developments permit assessment of both pre-synaptic and post-synaptic function ion dopaminergic pathways. These techniques are now being applied to studies of movement disorders in human subjects

  9. Positron emission tomography in movement disorders

    Energy Technology Data Exchange (ETDEWEB)

    Martin, W R.W.

    1985-02-01

    Positron emission tomography provides a method for the quantitation of regional function within the living human brain. Studies of cerebral metabolism and blood flow in patients with Huntington's disease, Parkinson's disease and focal dystonia have revealed functional abnormalities within substructures of the basal ganglia. Recent developments permit assessment of both pre-synaptic and post-synaptic function in dopaminergic pathways. These techniques are now being applied to studies of movement disorders in human subjects.

  10. Cambridge glioma trial of misonidazole and radiation therapy with associated pharmacokinetic studies

    International Nuclear Information System (INIS)

    Bleehen, N.M.

    1980-01-01

    Fifty-five patients with grade 3 and 4 supratentorial astrocytomas, were randomized into a three-limb study. At 9 months after the last treatment there were no differences in survival between the treatment groups. No cases of peripheral neuropathy were seen. Investigations into the possible cause of this are presented. It is thought that microsomal enzyme induction by the anticonvulsants phenobarbitone and phenytoin resulted in increased 0-demethylation of the misonidazole. Clinical data to confirm this view are presented. Current MRC protocols of misonidazole studies on gliomas and carcinomas of the cervix and head and neck are summarized

  11. Positron emission tomography experience with 2-[¹⁸F]fluoro-3-(2(S)-azetidinylmethoxy)pyridine (2-[¹⁸F]FA) in the living human brain of smokers with paranoid schizophrenia.

    Science.gov (United States)

    Brašić, James Robert; Cascella, Nicola; Kumar, Anil; Zhou, Yun; Hilton, John; Raymont, Vanessa; Crabb, Andrew; Guevara, Maria Rita; Horti, Andrew G; Wong, Dean Foster

    2012-04-01

    Utilizing postmortem data (Breese et al. [2000] Neuropsychopharmacology 23:351-364), we hypothesized that the densities of high-affinity neuronal α4β2 nicotinic acetylcholine receptors (nAChRs) in the brain exist in a continuum from highest to lowest as follows: smokers without schizophrenia > smokers with schizophrenia > nonsmokers without schizophrenia > nonsmokers with schizophrenia. Application of the Kruskal-Wallis Test (Statacorp, 2003) to the postmortem data (Breese et al. [2000] Neuropsychopharmacology 23:351-364) confirmed the hypothesized order in the cortex and the hippocampus and attained significance in the caudate and the thalamus. Positron emission tomography (PET) was performed for 60 min at 6 h after the intravenous administration of 444 megabequerels [MBq] (12 mCi) 2-[¹⁸F]fluoro-3-(2(S)-azetidinylmethoxy)pyridine (2-[¹⁸F]FA), a radiotracer for high-affinity neuronal α4β2 nAChRs, as a bolus plus continuous infusion to 10 adults (seven men and three women) (six smokers including five with paranoid schizophrenia and four nonsmokers) ranging in age from 22 to 56 years (mean 40.1, standard deviation 13.6). The thalamic nondisplaceable binding potential (BP(ND) ) was 1.32 ± 0.19 (mean ± standard deviation) for healthy control nonsmokers; 0.50 ± 0.19 for smokers with paranoid schizophrenia; and 0.51 for the single smoker without paranoid schizophrenia. The thalamic BP(ND) s of nonsmokers were significantly higher than those of smokers who smoked cigarettes a few hours before the scans (P = 0.0105) (StataCorp, 2003), which was likely due to occupancy of nAChRs by inhaled nicotine in smokers. Further research is needed to rule out the effects of confounding variables. Copyright © 2011 Wiley Periodicals, Inc.

  12. Prognostic significance of positron emission tomography using fluorine-18-fluorodeoxyglucose in patients treated for malignant lymphoma

    International Nuclear Information System (INIS)

    Cremerius, U.; Zimny, M.; Bares, R.; Buell, U.; Fabry, U.; Osieka, R.; Neuerburg, J.

    2001-01-01

    Aim: To evaluate the prognostic significance of positron emission tomography (PET) using fluorine-18-[2]-fluoro-2-deoxyglucose (FDG) in patients treated for Hodgkin's disease (HD) or non-Hodgkin's lymphoma (NHL) compared to conventional restaging (CRS). Methods: Fifty-six patients with either HD (n = 22), high-grade NHL (n = 26) or centrocytic-centroblastic NHL (n = 8) were included. PET was performed in 41 patients for treatment reevaluation up to three months after therapy and in patients with persisting residual masses (n = 10) or suspected relapse (n = 5) four to twelve months after treatment. The scans were evaluated qualitatively and quantitatively using standardised uptake values (SUV). Progression-free survival (PFS) was estimated to assess the prognostic value of FDG PET and clinical follow-up was taken as gold standard. Results: PET was positive in nineteen of 41 patients studied for treatment reevaluation. Progression was observed after a median interval of two months (range 0-15) in sixteen of 19 patients after a positive PET scan and in three of 22 patients after a negative scan (p 11.35 of lymphoma lesions was associated with poorer PFS than SUV [de

  13. Positron emission zone plate holography for particle tracking

    Energy Technology Data Exchange (ETDEWEB)

    Gundogdu, O. [University of Birmingham, School of Physics and Astronomy, Birmingham B15 2TT (United Kingdom)]. E-mail: o.gundogdu@surrey.ac.uk

    2006-01-15

    Positron Emission Particle Tracking (PEPT) is a powerful non-invasive technique that has been used extensively for tracking a single particle. In this paper, we present a study of zone plate holography method in order to track multiple particles, mainly two particles. The main aim is to use as small number of events as possible in the order to make it possible to track particles in fast moving industrial systems. A zone plate with 100% focal efficiency is simulated and applied to the Positron Emission Tomography (PET) data for multiple particle tracking. A simple trajectory code was employed to explore the effects of the nature of the experimental trajectories. A computer holographic reconstruction code that simulates optical reconstruction was developed. The different aspects of the particle location, particle activity ratios for enabling tagging of particles and zone plate and hologram locations are investigated. The effect of the shot noise is investigated and the limitations of the zone plate holography are reported.

  14. Positron emission zone plate holography for particle tracking

    International Nuclear Information System (INIS)

    Gundogdu, O.

    2006-01-01

    Positron Emission Particle Tracking (PEPT) is a powerful non-invasive technique that has been used extensively for tracking a single particle. In this paper, we present a study of zone plate holography method in order to track multiple particles, mainly two particles. The main aim is to use as small number of events as possible in the order to make it possible to track particles in fast moving industrial systems. A zone plate with 100% focal efficiency is simulated and applied to the Positron Emission Tomography (PET) data for multiple particle tracking. A simple trajectory code was employed to explore the effects of the nature of the experimental trajectories. A computer holographic reconstruction code that simulates optical reconstruction was developed. The different aspects of the particle location, particle activity ratios for enabling tagging of particles and zone plate and hologram locations are investigated. The effect of the shot noise is investigated and the limitations of the zone plate holography are reported

  15. Images to visualize the brain. PET: Positron Emission Tomography

    International Nuclear Information System (INIS)

    1992-01-01

    Diagnosis instrument and research tool, Positron Emission Tomography permits advanced technological developments on positron camera, on molecule labelling and principally on very complex 3D image processing. Cyceron Centre in Caen-France works on brain diseases and try to understand the mechanism of observed troubles and to assess the treatment efficiency with PET. Service Hospitalier Frederic Joliot of CEA-France establishes a mapping of cognitive functions in PET as vision areas, anxiety regions, brain organization of language, different attention forms, voluntary actions and motor functions

  16. The enhanced cytotoxicity of misonidazole in the thiol depleted state - An oxygen dependent mechanism

    International Nuclear Information System (INIS)

    Tuttle, S.W.; Varnes, M.E.; Donahue, L.; Biaglow, J.E.

    1985-01-01

    Incubating A549 cells in the presence of L-buthionine-S, R-sulfoximine and misonidazole under aerobic conditions results in lowered rates of cell growth and greater cytotoxicity than is seen with either drug alone. The authors previously demonstrated the accumulation of hydrogen peroxide from cells treated with misonidazole following the inhibition of GSH-peroxidase with thiol depleting agents. They hypothesize that the enhancement of misonidazole toxicity by L-BSO results from the increased exposure to hydrogen peroxide, and the possible formation of the highly reactive hydroxyl radical in the presence of trace metals via Fenton chemistry. Support for this hypothesis comes from their observations that addition of radical scavengers (such as SOD and catalase) and nutritional antioxidants (vitamin E) to the culture medium will partially inhibit the cytotoxic effects. Further work is being done to measure the products of reaction of toxic oxygen species with cellular macromolecules, i.e. lipids

  17. Usefulness of positron emission tomography (TEP) in the assessment of osteo-articular prosthesis; Utilite de la tomographie par emission de positons (TEP) dans l'etude des protheses osteo-articulaires

    Energy Technology Data Exchange (ETDEWEB)

    Maldonado, A.; Suarez, J.P.; Dominguez, M.L. [Centro PET Complutense, Madrid (Spain)

    2004-12-15

    Joint arthroplasty is performed with increasing frequency as the population ages. Loosening or infection of the prosthesis is a relatively common event that can limit the lifetime of a prosthesis. Accuracy differentiation between aseptic and septic loosening of the prosthesis remains a challenge because of the consequences for patient management. Moreover, an early diagnosis of infected hip prosthesis is very important for optimal and cost-effective management. Various approaches have developed to visualize infection and inflammation by nuclear medicine techniques. Recently positron emission tomography (PET) with fluorine-l8 labelled 2 fluoro-2-deoxyglucose ({sup 18}F-FDG) has been shown to delineate infectious and inflammatory foci with high sensitivity owing to the increased glucose metabolism in inflammatory cells. In this paper we review the role of FDG-PET in this common differential diagnosis in patients with total knee and hip prostheses. Different patterns of FDG-PET interpretation have been described as wed as methodological aspects. (author)

  18. ¹⁸F-fluorodeoxyglucose positron emission tomography-computed tomography for the evaluation of bone metastasis in patients with gastric cancer.

    Science.gov (United States)

    Ma, Dae Won; Kim, Jie-Hyun; Jeon, Tae Joo; Lee, Yong Chan; Yun, Mijin; Youn, Young Hoon; Park, Hyojin; Lee, Sang In

    2013-09-01

    The roles of positron emission tomography and bone scanning in identifying bone metastasis in gastric cancer are unclear. We compared the usefulness of positron emission tomography-computed tomography and scanning in detecting bone metastasis in gastric cancer. Data from 1485 patients diagnosed with gastric cancer who had undergone positron emission tomography-computed tomography and scanning were reviewed. Of 170 enrolled patients who were suspected of bone metastasis in either positron emission tomography or scanning, 81.2% were confirmed to have bone metastasis. The sensitivity, specificity, and accuracy were 93.5%, 25.0%, and 80.6%, respectively, for positron emission tomography and 93.5%, 37.5%, and 82.9%, respectively, for scanning. 87.7% of patients with bone metastasis showed positive findings on two modalities. 15.0% of solitary bone metastases were positive on positron emission tomography only. Positron emission tomography was superior to scanning for the detection of synchronous bone metastasis, but the two modalities were similar for the detection of metachronous bone metastasis. The concordance rate of response assessment after treatment between two modalities was moderate. Positron emission tomography-computed tomography may be more effective for the diagnosis of bone metastasis in the initial staging workup. Conversely, bone scanning and positron emission tomography-computed tomography may be similarly effective for the detection of metachronous bone metastasis. Copyright © 2013 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  19. Radiolysis of 2-[{sup 18}F]fluoro-2-deoxy-D-glucose ([{sup 18}F]FDG) and the role of ethanol and radioactive concentration

    Energy Technology Data Exchange (ETDEWEB)

    Jacobson, Mark S. [Division of Nuclear Medicine, Mayo Clinic, Rochester, MN (United States)], E-mail: jacobson.mark17@mayo.edu; Dankwart, Heather R. [Division of Nuclear Medicine, Mayo Clinic, Rochester, MN (United States); Mahoney, Douglas W. [Division of Biostatistics, Mayo Clinic, Rochester, MN (United States)

    2009-06-15

    Radiolysis is the process by which radioactively labeled compounds degrade. Many positron emission tomography (PET) radiopharmaceuticals produced with high radioactive concentrations and specific activities exhibit low radiochemical purity because of radiolysis. Little data exist that describe the radiolytic decomposition of 2-[{sup 18}F]fluoro-2-deoxy-D-glucose ([{sup 18}F]FDG). The objective of our study was to profile the degradation of [{sup 18}F]FDG at various radioactive concentrations by measuring radiochemical purity at different time intervals and to study the effects of ethanol, a well-known reductant stabilizer of [{sup 18}F]FDG preparations.

  20. Time-of-flight positron emission tomography and associated detectors

    International Nuclear Information System (INIS)

    Vacher, J.; Allemand, R.; Campagnolo, R.

    1983-04-01

    An analysis of the timing capabilities of the detectors (scintillators and photomultipliers) in time-of-flight positron emission tomography is presented. The advantages of BaF 2 compared with CsF for the futur tomographs are evaluated [fr

  1. Positron emission intensities in the decay of 64Cu, 76Br and 124I

    International Nuclear Information System (INIS)

    Qaim, S.M.; Bisinger, T.; Hilgers, K.; Nayak, D.; Coenen, H.H.

    2007-01-01

    The relatively long-lived positron emitters 64 Cu (t 1/2 = 12.7 h), 76 Br (t 1/2 = 16.2 h) and 124 I (t 1/2 = 4.18 d) are finding increasing applications in positron emission tomography (PET). For precise determination of their positron emission intensities, each radionuclide was prepared via a charged particle induced reaction in a ''no-carrier-added'' form and with high radionuclidic purity. It was then subjected to γ-ray and X-ray spectroscopy as well as to anticoincidence beta and γγ-coincidence counting. The positron emission intensities measured were: 64 Cu (17.8 ± 0.4)%, 76 Br (58.2 ± 1.9)% and 124 I (22.0 ± 0.5)%. The intensity of the weak 1346 keV γ-ray emitted in the decay of 64 Cu was determined as (0.54 ± 0.03)%. Some implications of the precisely determined nuclear data are discussed. (orig.)

  2. Acquisition of resistance to antitumor alkylating agent ACNU: a possible target of positron emission tomography monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Kawai, Hideya [Department of Neurosurgery, Faculty of Medical Sciences, University of Fukui, Fukui 910-1193 (Japan); Research Institute of Brain and Blood Vessels, Akita 010-0874 (Japan); Toyohara, Jun [Radiopharmaceutical Chemistry Section, Department of Medical Imaging, National Institute of Radiological Sciences, Chiba 263-8555 (Japan); Biomedical Imaging Research Center, University of Fukui, Fukui 910-1193 (Japan); Kado, Hirotsugu [Research Institute of Brain and Blood Vessels, Akita 010-0874 (Japan); Nakagawa, Takao [Department of Neurosurgery, Faculty of Medical Sciences, University of Fukui, Fukui 910-1193 (Japan); Takamatsu, Shinji [Biomedical Imaging Research Center, University of Fukui, Fukui 910-1193 (Japan); Furukawa, Takako [Biomedical Imaging Research Center, University of Fukui, Fukui 910-1193 (Japan); Yonekura, Yoshiharu [Biomedical Imaging Research Center, University of Fukui, Fukui 910-1193 (Japan); Kubota, Toshihiko [Department of Neurosurgery, Faculty of Medical Sciences, University of Fukui, Fukui 910-1193 (Japan); Fujibayashi, Yasuhisa [Biomedical Imaging Research Center, University of Fukui, Fukui 910-1193 (Japan)]. E-mail: yfuji@fmsrsa.fukui-med.ac.jp

    2006-01-15

    Early detection of tumor response to chemotherapy is of great importance for appropriate treatment of tumors. In this study, characteristics of two positron emission tomography (PET) tracers, [{sup 18}F]2-fluoro-2-deoxy-D-glucose (FDG) and[{sup 18}F]3'-fluoro-3'-deoxy-thymidine (FLT), in the early detection of tumor cell response as well as tolerance development to chemotherapy was compared using rat C6 glioma cells and 1-(4-amino-2-methyl-5-pyrimidinyl)-methyl-3-(2-chloroethyl) -3-nitrosoureahydrochloride (ACNU). ACNU is an alkylating agent known to induce drug resistance through expression of O {sup 6}-methylguanine-deoxyribonucleic acid methyl transferase (O {sup 6}-MGMT). We established an ACNU-resistant C6 glioma cell line (C6/ACNU) and investigated the effect of ACNU on the uptake of FLT and FDG. In C6 cells, DNA synthesis presented as [{sup 3}H]thymidine ([{sup 3}H]Thd) incorporation into DNA was quickly suppressed by ACNU. In C6/ACNU cells, the suppression was recovered promptly, indicating that DNA alkylation occurs initially but highly expressed O {sup 6}-MGMT repairs DNA, leading to the recovery of DNA synthesis. The patterns of FLT uptake in C6 and C6/ACNU were difficult to distinguish in the very early stage of the treatment, though it was reported that FLT uptake well correlated with proliferation in certain conditions. FDG uptake showed different patterns between the resistant and control cells, with significantly decreased uptake in C6 cells and unchanged uptake in C6/ACNU cells at 18-24 h after the treatment. Though difficult to be directly translated into clinical situation, the present study will provide a base to develop an appropriate protocol to assess tumor response to treatment by PET and to design effective treatment plans.

  3. Positron emission tomography with additional γ-ray detectors for multiple-tracer imaging.

    Science.gov (United States)

    Fukuchi, Tomonori; Okauchi, Takashi; Shigeta, Mika; Yamamoto, Seiichi; Watanabe, Yasuyoshi; Enomoto, Shuichi

    2017-06-01

    Positron emission tomography (PET) is a useful imaging modality that quantifies the physiological distributions of radiolabeled tracers in vivo in humans and animals. However, this technique is unsuitable for multiple-tracer imaging because the annihilation photons used for PET imaging have a fixed energy regardless of the selection of the radionuclide tracer. This study developed a multi-isotope PET (MI-PET) system and evaluated its imaging performance. Our MI-PET system is composed of a PET system and additional γ-ray detectors. The PET system consists of pixelized gadolinium orthosilicate (GSO) scintillation detectors and has a ring geometry that is 95 mm in diameter with an axial field of view of 37.5 mm. The additional detectors are eight bismuth germanium oxide (BGO) scintillation detectors, each of which is 50 × 50 × 30 mm 3 , arranged into two rings mounted on each side of the PET ring with a 92-mm-inner diameter. This system can distinguish between different tracers using the additional γ-ray detectors to observe prompt γ-rays, which are emitted after positron emission and have an energy intrinsic to each radionuclide. Our system can simultaneously acquire double- (two annihilation photons) and triple- (two annihilation photons and a prompt γ-ray) coincidence events. The system's efficiency for detecting prompt de-excitation γ-rays was measured using a positron-γ emitter, 22 Na. Dual-radionuclide ( 18 F and 22 Na) imaging of a rod phantom and a mouse was performed to demonstrate the performance of the developed system. Our system's basic performance was evaluated by reconstructing two images, one containing both tracers and the other containing just the second tracer, from list-mode data sets that were categorized by the presence or absence of the prompt γ-ray. The maximum detection efficiency for 1275 keV γ-rays emitted from 22 Na was approximately 7% at the scanner's center, and the minimum detection efficiency was 5.1% at the edge of

  4. Attenuation Correction Strategies for Positron Emission Tomography/Computed Tomography and 4-Dimensional Positron Emission Tomography/Computed Tomography

    OpenAIRE

    Pan, Tinsu; Zaidi, Habib

    2013-01-01

    This article discusses attenuation correction strategies in positron emission tomography/computed tomography (PET/CT) and 4 dimensional PET/CT imaging. Average CT scan derived from averaging the high temporal resolution CT images is effective in improving the registration of the CT and the PET images and quantification of the PET data. It underscores list mode data acquisition in 4 dimensional PET and introduces 4 dimensional CT popular in thoracic treatment planning to 4 dimensional PET/CT. ...

  5. Positron emission tomography takes lead

    International Nuclear Information System (INIS)

    Simms, R.

    1989-01-01

    Positron emission tomography (PET)'s ability to detect functional abnormalities before they manifest anatomically is examined and some of its most common applications are outlined. It is emphasised that when PET facility and Australian Nuclear Science and Technology Organization's national cyclotron are established at the Royal Prince Alfred Hospital, the availability of short-lived tracers such as oxygen 15, nitrogen 13 and fluorine 18 would improve the specificity of tests(e.g. for brain tumors or cardiac viability) further. Construction of the cyclotron will start shortly and is due to be completed and operating by the end of 1991

  6. Relationship between misonidazole toxicity and core temperature in C3H mice

    International Nuclear Information System (INIS)

    Gomer, C.J.; Johnson, R.J.

    1979-01-01

    A single intraperitoneal injection of the radiation sensitizer misonidazole at doses greater than 0.5 mg/g was found to produce a transient hypothermic response in C3H mice. An increase in the acute toxicity of this drug was demonstrated when the animal core temperature was maintained at a normal 35 to 37 0 C by placing the mice in a warmed environment immediately following injection of the drug. The LD/sub 50/3 days/ dose of misonidazole was determined to be 1.48 mg/g for mice allowed to become hypothermic following injection but 0.77 mg/g for mice maintained at a normal core temperature following injection

  7. Metabolism and radiosensitization of 4,5-dimethylmisonidazole, a ring-substituted analog of misonidazole

    International Nuclear Information System (INIS)

    Born, J.L.; Smith, B.R.; Harper, N.; Koch, C.J.

    1992-01-01

    In the present study, methyl groups were added to the imidazole ring of misonidazole in order to hinder adduct formation with cellular molecules after reductive-activation of the compound. It was anticipated that this would substantially decrease the hypoxic-cell toxicity of the parent drug. The presence of the two methyl groups reduced the half-wave reduction potential of dimethyl misonidazole (DMM) by about 70 mV, so we expected that its radiosensitizing ability would also decrease. In direct comparison with misonidazole, DMM, at equimolar concentrations, showed dramatically reduced binding to cellular macromolecules under bioreductive conditions, both in vivo, using a liver perfusion system, and in vitro, using tissue culture cells incubated under extreme hypoxia. However, DMM was only moderately less toxic than the parent compound, and showed greatly diminished radiation sensitization capacity. Since the decrease in toxicity was much less than expected, and the decrease in radiosensitization was much more than expected, this compound may be an important drug for continuing studies on the mechanisms of radiation sensitization, binding and cytotoxicity caused by electron affinic drugs. (Author)

  8. A controlled trial of misonidazole in the curative treatment of infiltrating bladder cancer

    International Nuclear Information System (INIS)

    Bydder, P.V.; Burry, A.F.; Gowland, S.; Bourne, R.G.; Chapman, P.; Firth, L.A.; Gray, A.J.; McIlroy, R.

    1989-01-01

    Between 1980 and 1983 a total of 89 patients with infiltrating transitional cell carcinoma of the bladder were entered into a multi centre randomised controlled clinical trial with either misonidazole or placebo added to the first 40.00 Gy of radiotherapy. Depending on their referring clinician, patients then completed treatment with either further radiotherapy to a radical dose, or surgery four weeks later. All patients have been followed up for a minimum of three years, and no significant difference has been found in local control, survival, or pathological downstaging of the tumour. The neurotoxicity was considerable, with 43% of patients receiving misonidazole developing a peripheral neuropathy, starting five weeks on average after beginning treatment, and with a mean duration of 27 months. Eighty per cent of patients affected still had peripheral neuropathy at three years or their prior death. There is a suggestion that alcohol may predispose to the neuropathy. This study failed to show any benefit of misonidazole in tumour control and produced unacceptably high levels of toxicity. 14 refs., 8 figs., 9 tabs

  9. Endogenous endophthalmitis caused by Cryptococcus neoformans Var. Gattii mimicking choroidal tumor: From positron-emission tomography/computed tomography to histopathology

    Directory of Open Access Journals (Sweden)

    Chun-Ju Lin

    2017-01-01

    Full Text Available A 60-year-old immunocompetent female with pneumonia history about 10 years ago suffered from blurred vision overall survival for 3 weeks. Common cold with headache and unintentional body weight loss was also noted recently. Choroidal detachment simulating choroidal tumor was observed in the temporal quadrant. The 18F-fluoro-2-deoxyglucose (FDG positron-emission tomography/computed tomography (CT scan showed focal, mild to moderate FDG uptake in the left lateral orbit, and an enhanced lesion was seen on the recent CT scan. The suspicious choroidal tumor became larger in a week. Phacoemulsification, vitrectomy, and retinal biopsies were performed. Histochemical study of the retinal specimens established the diagnosis of endogenous cryptococcal endophthalmitis. Vitreous culture yielded Cryptococcus neoformans var. gattii. Systemic and topical voriconazole eliminated the infection. In the literature, endogenous endophthalmitis caused by C. neoformans var. gattii has not been reported in detail. The key to successful management lies in early diagnosis. If clinical improvement could not be achieved after conventional management and imaging studies have failed to yield a definite diagnosis, retinal biopsy can be considered.

  10. Quantification in dynamic and small-animal positron emission tomography

    NARCIS (Netherlands)

    Disselhorst, Johannes Antonius

    2011-01-01

    This thesis covers two aspects of positron emission tomography (PET) quantification. The first section addresses the characterization and optimization of a small-animal PET/CT scanner. The sensitivity and resolution as well as various parameters affecting image quality (reconstruction settings, type

  11. A new liquid xenon scintillation detector for positron emission tomography

    International Nuclear Information System (INIS)

    Chepel, V.Yu.

    1993-01-01

    A new positron-sensitive detector of annihilation photons filled with liquid xenon is proposed for positron emission tomography. Simultaneous detection of both liquid xenon scintillation and ionization current produces a time resolution of < 1 ns and a position resolution in the tangential direction of the tomograph ring is ∼ 1 mm and in the radial direction is ∼ 5 mm. The advantages of a tomograph with new detectors are discussed. New algorithms of Compton scattering can be used. (author)

  12. Positron emission tomography for diagnosis of Alzheimer's disease and vascular dementia

    International Nuclear Information System (INIS)

    Mielke, R.; Heiss, W.-D.

    1998-01-01

    In mild or atypical cases of Alzheimer's disease (AD) the differential diagnosis to other dementing diseases, such as vascular dementia (VD), may pose a difficult problem. Beside computed tomography (CT) and magnetic resonance imaging (MRI), functional neuroimaging by positron emission tomography (PET). Support the clinical diagnosis by visualizing cerebral function. PET of 18 F-2-fluoro-2-deoxy-D-glucose (FDG) for measurement of regional cerebral glucose metabolism (rCMRGl) has shown a typical metabolic pattern in patients with probable AD: hypometabolism in temporoparietal and frontal association areas, but relative recessing of primary cortical areas, basal ganglia and cerebellum. In VD a different pattern is seen. It consists of scattered areas with reduction of rCMRGl typically extending over cortical and subcortical structures. Severity of dementia is correlated with rCMRGl reduction in the temporoparietal association cortex, irrespective of the cause of dementia. Also the total volume of hypometabolic regions is related to severity of dementia but did not differ between AD and VD, even in patients with small lacunar infarction. This indicates that the total volume of functional tissue loss is more important, since it also includes the effects of incompletely infarcted tissue and morphologically intact but deafferented cortex. The characteristic metabolic pattern has a high diagnostic accuracy for the discrimination between probable AD, normals and VD, even in patients with mild cognitive impairment. Under clinical and therapeutic aspects the analysis of longitudinal changes of rCMRGl has shown that neuropsychological and metabolic changes are closely related in both, AD and VD. (author)

  13. [Usefulness of ¹⁸F-fluoro-2-deoxyglucose positron emission tomography in evaluation of gastric cancer stage].

    Science.gov (United States)

    Yoon, Na Ri; Park, Jae Myung; Jung, Hee Sun; Cho, Yu Kyung; Lee, In Seok; Choi, Myung Gyu; Chung, In Sik; Song, Kyo Young; Park, Cho Hyun

    2012-05-01

    The usefulness of ¹⁸F-fluoro-2-deoxyglucose (FDG)-PET in detecting primary cancer, lymph node metastasis, and distant metastasis were studied in the gastric cancer patients. The subjects were 392 gastric cancer patients who received FDG-PET and an abdominal CT test prior to surgery. The results of FDG-PET and CT were compared with the surgical and pathologic results. The primary site detection rate of FDG-PET was 74.4%, 50.3% in early gastric cancer and 92.0% in advanced gastric cancer. Detection rate was higher when tumors were larger than 3.5 cm, had deeper depth of invasion, and at a later stage (pusefullness of FDG-PET is limited to the advanced stage. Diagnostic value of this test was not superior to CT. However, FDG-PET may be useful in detecting synchronous double primary cancers.

  14. 18F-fluorodeoxyglucose positron emission tomography in colorectal cancer: value in primary staging and follow-up

    International Nuclear Information System (INIS)

    Joerg, L.; Heinisch, M.; Rechberger, E.; Kurz, F.; Klug, R.; Aufschnaiter, M; Hammer, J.; Langsteger, W.

    2002-01-01

    Positron emission tomography using 18 F-fluorodeoxyglucose (FDG-PET) is a encouraging imaging techniques allowing a highly sensitive whole-body search for malignant foci detected by their increased glucose metabolism compared with benign tissues. Several studies are now available that indicate its added value for diagnosis and staging of colorectal cancer. In all, patient management seems to be changed in 20-30 % of patients who undergo fluorodeoxyglucose positron emission tomography in addition to standard staging procedures. Fluorodeoxyglucose positron emission tomography is also useful in monitoring radiation therapy and chemotherapy. Regarding preoperative staging of primary colorectal cancer the literature is very limited. (author)

  15. 4.5 Tesla magnetic field reduces range of high-energy positrons -- Potential implications for positron emission tomography

    International Nuclear Information System (INIS)

    Wirrwar, A.; Vosberg, H.; Herzog, H.; Halling, H.; Weber, S.; Mueller-Gaertner, H.W.; Forschungszentrum Juelich GmbH

    1997-01-01

    The authors have theoretically and experimentally investigated the extent to which homogeneous magnetic fields up to 7 Tesla reduce the spatial distance positrons travel before annihilation (positron range). Computer simulations of a noncoincident detector design using a Monte Carlo algorithm calculated the positron range as a function of positron energy and magnetic field strength. The simulation predicted improvements in resolution, defined as full-width at half-maximum (FWHM) of the line-spread function (LSF) for a magnetic field strength up to 7 Tesla: negligible for F-18, from 3.35 mm to 2.73 mm for Ga-68 and from 3.66 mm to 2.68 mm for Rb-82. Also a substantial noise suppression was observed, described by the full-width at tenth-maximum (FWTM) for higher positron energies. The experimental approach confirmed an improvement in resolution for Ga-68 from 3.54 mm at 0 Tesla to 2.99 mm FWHM at 4.5 Tesla and practically no improvement for F-18 (2.97 mm at 0 Tesla and 2.95 mm at 4.5 Tesla). It is concluded that the simulation model is appropriate and that a homogeneous static magnetic field of 4.5 Tesla reduces the range of high-energy positrons to an extent that may improve spatial resolution in positron emission tomography

  16. Positron Emission Tomography : background, possibilities and perspectives in neuroscience

    NARCIS (Netherlands)

    Paans, AMJ

    Positron Emission Tomography (PET) is a method for determining biochemical and physiological processes in vivo in a quantitative way. This includes the measurement of the pharmacokinetics of labeled drugs and the measurement of the effects of drugs and/or therapy on metabolism. Also deviations of

  17. Direct fluorination of melatonin and 5-hydroxy-L-tryptophan with [18F]F2

    International Nuclear Information System (INIS)

    Chirakal, R.; Firnau, G.; Garnett, E.S.

    1986-01-01

    In order that melatonin receptors may be studied in man with positron emission tomography, melatonin labelled with a positron emitting isotope is needed. The preparation of 6-fluoro-melatonin labelled with F-18 is described. Using the same fluorination method, 5-hydroxy-6-(F-18)fluorotryptophan and 4-(F-18)fluoro-5-hydroxy-tryptophan were also prepared. (UK)

  18. Potentials of positron emission tomography for regional cerebral blood flow evaluation

    International Nuclear Information System (INIS)

    Depresseux, J.C.

    1982-01-01

    A general overview of the potentials of positron emission tomography and of positron-emitting radiopharmaceuticals for the evaluation of regional cerebral blood flow is proposed and discussed. Specific characteristics of this technique are described, with special stress on conceptual and methodological implications. Four different approaches to the problem of the determination of cerebral blood flow are distinguished: trapping equilibrium methods, steady state equilibrium methods, clearance methods and convoluted kinetic methods [fr

  19. Comparison of cancer glucose utilization indexes by positron emission tomography using fluorine-18-fluoro-deoxyglucose

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Kyosan (Chiba Univ. (Japan). School of Medicine)

    1994-08-01

    Positron emission tomography (PET) using fluorine-18-fluorodeoxyglucose (FDG) has been used to diagnose various kinds of malignant tumors. Various indexes are calculated for evaluation of tumor glucose metabolism from FDG PET image. Some indexes need sequential multiple-time uptake data and arterial plasma FDG concentrations (dynamic study). But some indexes use only static image data to calculate. We calculated four kinds of indexes on each patient, and analyzed the correlation of each index with others. Previously untreated 35 patients (23 non-Hodgikin's lymphoma, 4 lung cancers, 2 epipharynx cancers and other 6 malignant tumors) were studied by FDG PET. In all patients, about 4 mCi (148 MBq) of FDG was injected intravenously in a fasting state, and a series of 2-min sequential scans was acquired for 60 min following injection. After sequential scans, 6-min scan was successively added for obtaining static image. The rate constants (k[sub 1]-k[sub 4]) calculated by non-linear least squares fitting routines, the slope of Patlak-Gjedde plot, differential absorption ratio (DAR) which represents tumor activity corrected by administrated dose per body weight, and tumor-to-normal soft-tissue contrast ratios (TCR) were calculated for each patient. The correlation of these indexes was analyzed statistically. Patlak-Gjedde plot seemed to be widely accepted for measuring tumor glucose metabolism, but it needs dynamic study data. DAR is a simple index easily calculated using static data. Our results showed that the slope of Patlak-Gjedde plot and DAR were closely correlated. It was suggested that the DAR could be used in place of Patlak-Gjedde plot. They also showed relatively well correlation with each other. Correlation between rate constant k[sub 3] and other indexes were from 0.67 to 0.43. It is acceptable result because rate constant K[sub 3] related the activity of hexokinase but other indexes may represent the overall glucose metabolism of the tumor tissue. (J.N.P.).

  20. Fluorodeoxyglucose-positron emission tomography/computed tomography imaging features of colloid adenocarcinoma of the lung: a case report.

    Science.gov (United States)

    Wang, ZhenGuang; Yu, MingMing; Chen, YueHua; Kong, Yan

    2017-07-27

    Colloid adenocarcinoma of the lung is a rare subtype of variants of invasive adenocarcinomas. We report the appearance of this unusual entity on 18 F-fluorodeoxyglucose positron emission tomography/computed tomography. A 60-year-old man of Chinese Han nationality coughed with a little white sputum for 1 month. Chest computed tomography showed multiple bilateral subpleural nodules and plaques accompanied by air bronchograms, which were most concentrated in the lower lobe of his right lung. Positron emission tomography indicated increased radioactivity uptake with a maximum standardized uptake value of 3.5. Positron emission tomography/computed tomography showed a soft tissue density lesion in his left adrenal gland with a maximum standardized uptake value of 4.1. The positron emission tomography/computed tomography appearance suggested a primary colloid adenocarcinoma in the lower lobe of his right lung accompanied by intrapulmonary and left adrenal gland metastases. The diagnostic rate of colloid adenocarcinoma can be increased by combining the anatomic and metabolic information of lesions. The advantage of positron emission tomography/computed tomography in the diagnosis of colloid adenocarcinoma, as with other cancers, is the ability to locate extrapulmonary disease, facilitating clinical staging.

  1. Fluorodeoxyglucose and C-Choline positron emission tomography for distinction of metastatic plexopathy and neuritis : a case report

    NARCIS (Netherlands)

    Bartels, Anna L.; Zeebregts, Clark J; Enting, Roeline; Slart, Riemer Hja

    2009-01-01

    INTRODUCTION: Fluorodeoxyglucose positron emission tomography scanning has an established role in the diagnostic work-up of many malignant diseases and also in the evaluation of cancer treatment response. Fluorodeoxyglucose positron emission tomography may, however be non-specific as infectious

  2. Cobalt-55 positron emission tomography in recurrent ischaemic stroke

    NARCIS (Netherlands)

    De Reuck, J; Santens, P; Keppens, J; De Bleecker, J; Strijckmans, K; Goethals, P; Lemahieu, [No Value; Korf, J

    The present study investigates if Cobalt-55 (Co-55) positron emission tomography (PET) allows us to distinguish and detect recent, recurrent strokes in patients who had already suffered a previous infarct in the same vascular territory. Fourteen patients with recurrent strokes underwent a Co-55 PET

  3. Positron emission tomography of incidentally detected small pulmonary nodules

    DEFF Research Database (Denmark)

    Fischer, B M; Mortensen, J; Dirksen, A

    2004-01-01

    The aim of this study was to assess the value of fluorodeoxyglucose positron emission tomography (FDG PET) imaging of small pulmonary nodules incidentally detected by spiral computed tomography (CT) in a high-risk population. Ten patients (five females, five males, aged 54-72 years) were recruited...

  4. Positron emission tomography in presurgical diagnosis of partial epilepsies

    International Nuclear Information System (INIS)

    Hajek, M.; Leenders, K.L.; Wieser, H.G.

    1992-01-01

    We present results of studies in which positron emission tomography was applied to the presurgical evaluation of epileptics. Emphasis is placed on results of PET studies with various tracers in partial epilepsies and on the use of PET in age-related epileptic syndromes in children. (orig.) [de

  5. Synthesis and preclinical characterization of 1-(6'-deoxy-6'-[18F]fluoro-β-d-allofuranosyl)-2-nitroimidazole (β-6'-[18F]FAZAL) as a positron emission tomography radiotracer to assess tumor hypoxia.

    Science.gov (United States)

    Wanek, Thomas; Kreis, Katharina; Križková, Petra; Schweifer, Anna; Denk, Christoph; Stanek, Johann; Mairinger, Severin; Filip, Thomas; Sauberer, Michael; Edelhofer, Patricia; Traxl, Alexander; Muchitsch, Viktoria E; Mereiter, Kurt; Hammerschmidt, Friedrich; Cass, Carol E; Damaraju, Vijaya L; Langer, Oliver; Kuntner, Claudia

    2016-11-01

    Positron emission tomography (PET) using fluorine-18 ( 18 F)-labeled 2-nitroimidazole radiotracers has proven useful for assessment of tumor oxygenation. However, the passive diffusion-driven cellular uptake of currently available radiotracers results in slow kinetics and low tumor-to-background ratios. With the aim to develop a compound that is actively transported into cells, 1-(6'-deoxy-6'-[ 18 F]fluoro-β-d-allofuranosyl)-2-nitroimidazole (β-[ 18 F]1), a putative nucleoside transporter substrate, was synthetized by nucleophilic [ 18 F]fluoride substitution of an acetyl protected labeling precursor with a tosylate leaving group (β-6) in a final radiochemical yield of 12±8% (n=10, based on [ 18 F]fluoride starting activity) in a total synthesis time of 60min with a specific activity at end of synthesis of 218±58GBq/μmol (n=10). Both radiolabeling precursor β-6 and unlabeled reference compound β-1 were prepared in multistep syntheses starting from 1,2:5,6-di-O-isopropylidene-α-d-allofuranose. In vitro experiments demonstrated an interaction of β-1 with SLC29A1 and SLC28A1/2/3 nucleoside transporter as well as hypoxia specific retention of β-[ 18 F]1 in tumor cell lines. In biodistribution studies in healthy mice β-[ 18 F]1 showed homogenous tissue distribution and excellent metabolic stability, which was unaffected by tissue oxygenation. PET studies in tumor bearing mice showed tumor-to-muscle ratios of 2.13±0.22 (n=4) at 2h after administration of β-[ 18 F]1. In ex vivo autoradiography experiments β-[ 18 F]1 distribution closely matched staining with the hypoxia marker pimonidazole. In conclusion, β-[ 18 F]1 shows potential as PET hypoxia radiotracer which merits further investigation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Dynamic positron emission tomography for study of cerebral hemodynamics in a cross section of the head using positron-emitting 68Ga-EDTA and 77Kr

    International Nuclear Information System (INIS)

    Yamamoto, Y.L.; Thompson, C.J.; Meyer, E.; Robertson, J.S.; Feindel, W.

    1977-01-01

    Dynamic positron emission tomographic studies were performed on over 120 patients with occlusive cerebrovascular disease, arteriovenous malformations, and brain tumors, using the positron section scanner, consisting of a ring of 32 scintillation detectors. The radiopharmaceuticals were nondiffusible 68 Ga-EDTA for transit time and uptake studies and the diffusible tracer, 77 Kr, for quantitative regional cerebral blood flow studies in every square centimeter of the cross section of the head. The results of dynamic positron emission tomography in correlation with the results from the gamma scintillation camera dynamic studies and computed tomography (CT) scans are discussed

  7. Radiosensitization of tumors and normal tissues by combined treatment with misonidazole and heat

    International Nuclear Information System (INIS)

    Hofer, K.G.; MacKinnon, A.R.; Schubert, A.L.; Lehr, J.E.; Grimmett, E.V.

    1981-01-01

    Combination treatment of mice with misonidazole (0.5 mg/g body wt.) and hyperthermia (41.5/sup o/C for 45 mins.) produced dramatic radiosensitization in hypoxic BP-8 murine sarcoma cells. The dose modifying factor (DMF: 4.3) was such that hypoxic BP-8 cells subjected to combination therapy became more radiosensitive than untreated, fully oxygenated cell populations. In contrast, radiosensitization by combination treatment was comparatively minor or completely absent in normal body tissues such as skin (DMF: 1.57), intestine (DMF: 1.0), and bone marrow (DMF: 1.0). These results suggest that simultaneous administration of misonidazole and hyperthermia may prove an effective adjuvant to conventional clinical radiation therapy

  8. 3D fast reconstruction in positron emission tomography

    International Nuclear Information System (INIS)

    Egger, M.L.; Scheurer, A. Hermann; Joseph, C.; Morel, C.

    1996-01-01

    The issue of long reconstruction times in positron emission tomography (PET) has been addressed from several points of view, resulting in an affordable dedicated system capable of handling routine 3D reconstructions in a few minutes per frame : on the hardware side using fast processors and a parallel architecture, and on the software side, using efficient implementation of computationally less intensive algorithms

  9. Para neoplastic syndromes: Usefulness of 18F-fluoro-deoxy-glucose (F.D.G.) positron emission tomography (PET)

    International Nuclear Information System (INIS)

    Banayan, S.; Janier, M.; Guillerma-Zucchi, N.; Billotey, C.; Ninet, J.; Delmas, P.; Thivolet, C.; Pellet, O.

    2008-01-01

    Background We evaluated the performance of 18 F-fluorodeoxyglucose ( 18 F.D.G.) positron emission tomography (PET) in the diagnosis of underlying malignancy in cases of suspected para neoplastic syndrome (P.S.). Methods 18 F.D.G.-PET was performed in 31 patients, clinically suspected to have P.S.. The P.S. were 34, among which 12 neurological diseases, eight endocrine, seven rheumatological, one dermatological and six vascular. We compared computed tomography (CT), iodine-enhanced most of the time, and 18 F.D.G.-PET reports to clinicians definitive conclusion at the end of the work-up and a follow-up period of, at least, two months. Results We obtained a histological diagnosis of cancer for ten patients, but could only identify the primary site of malignancy for nine of them. 18 F.D.G.-PET showed six primary sites among which three were not seen on CT. CT disclosed four primary sites, among which one was not seen on 18 F.D.G.-PET. In one case, 18 F.D.G.-PET disclosed regional lymph node metastases whereas these were not identified by CT. Eleven non-neoplastic causes were evidenced, among which 18 F.D.G.-PET played a major role in three cases. Ten causes were still undetermined at the end of the study. Conclusion Whole-body 18 F.D.G.-PET study plays an important role in the identification of underlying malignancy in clinically suspected para neoplastic syndromes; either by identifying the primary tumor or by directing biopsy of metastases. Furthermore, it can identify non-neoplastic causes. (authors)

  10. Three-dimensional imaging of hidden objects using positron emission backscatter

    International Nuclear Information System (INIS)

    Lee, Dongwon; Cowee, Misa; Fenimore, Ed; Galassi, Mark; Looker, Quinn; Mcneil, Wendy V.; Stonehill, Laura; Wallace, Mark

    2009-01-01

    Positron emission backscatter imaging is a technique for interrogation and three-dimensional (3-D) reconstruction of hidden objects when we only have access to the objects from one side. Using time-of-flight differences in detected direct and backscattered positron-emitted photons, we construct 3-D images of target objects. Recently at Los Alamos National Laboratory, a fully three-dimensional imaging system has been built and the experimental results are discussed in this paper. Quantitative analysis of images reconstructed in both two- and three-dimensions are also presented.

  11. Positron emission computerized tomography: a potential tool for in vivo quantitation of the distribution of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Huebner, K.F.; King, P.; Gibbs, W.D.; Washburn, L.C.; Hayes, R.L.

    1981-01-01

    The principles and some of the difficulties in quantitative positron emission computerized tomography have been discussed. We have shown that randoms and scattered events are a major cause of noise and counting errors in positron emission computerized tomography. The noise has been identified as a convoluting process and a mathematical solution has been presented. Examples of phantom studies and in vivo measurements have demonstrated that the distribution of positron emitting radiopharmaceuticals can be quantitated with much improved accuracy using the deconvolution equation to remove undesired noise

  12. Distinguishing tumor recurrence from irradiation sequelae with positron emission tomography in patients treated for larynx cancer

    International Nuclear Information System (INIS)

    Greven, K.M.; Williams, D.W. III; Keyes, J.W. Jr.; McGuirt, W.F.; Harkness, B.A.; Watson, N.E. Jr.; Raben, M.; Frazier, L.C.; Geisinger, K.R.; Capellari, J.O.

    1994-01-01

    Distinguishing persistent or recurrent tumor from postradiation edema, or soft tissue/cartilage necrosis in patients treated for carcinoma of the larynx can be difficult. Because recurrent tumor is often submucosal, multiple deep biopsies may be necessary before a diagnosis can be established. Positron emission tomography with 18F-2-fluro-2-deoxglucose (FDG) was studied for its ability to aid in this problem. Positron emission tomography (18FDG) scans were performed on 11 patients who were suspected of having persistent or recurrent tumor after radiation treatment for carcinoma of the larynx. Patients underwent thorough history and physical examinations, scans with computerized tomography, and pathologic evaluation when indicated. Standard uptake values were used to quantitate the FDG uptake in the larynx. The time between completion of radiation treatment and positron emission tomography examination ranged from 2 to 26 months with a median of 6 months. Ten patients underwent computed tomography (CT) of the larynx, which revealed edema of the larynx (six patients), glottic mass (four patients), and cervical nodes (one patient). Positron emission tomography scans revealed increased FDG uptake in the larynx in five patients and laryngectomy confirmed the presence of carcinoma in these patients. Five patients had positron emission tomography results consistent with normal tissue changes in the larynx, and one patient had increased FDG uptake in neck nodes. This patient underwent laryngectomy, and no cancer was found in the primary site, but nodes were pathologically positive. One patient had slightly elevated FDG uptake and negative biopsy results. The remaining patients have been followed for 11 to 14 months since their positron emission studies and their examinations have remained stable. In patients without tumor, average standard uptake values of the larynx ranged from 2.4 to 4.7, and in patients with tumor, the range was 4.9 to 10.7. 18 refs., 3 figs., 1 tab

  13. Imaging Atherosclerosis with Hybrid Positron Emission Tomography/Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Ripa, Rasmus Sejersten; Kjær, Andreas

    2015-01-01

    Noninvasive imaging of atherosclerosis could potentially move patient management towards individualized triage, treatment, and followup. The newly introduced combined positron emission tomography (PET) and magnetic resonance imaging (MRI) system could emerge as a key player in this context. Both...

  14. Failure of misonidazole-sensitized radiotherapy to impact upon outcome among stage III-IV squamous cancers of the head and neck

    International Nuclear Information System (INIS)

    Fazekas, J.; Pajak, T.F.; Wasserman, T.; Marcial, V.; Davis, L.; Kramer, S.; Rotman, M.; Stetz, J.

    1987-01-01

    As part of the RTOG research effort in the treatment of advanced, inoperable squamous cancer of the head and neck region, the hypoxic cell sensitizer, misonidazole, was selected for investigation as an adjuvant to definitive irradiation. Based upon a pilot experience (78-02) showing a 67% complete response rate among 36 AJC Stage III-IV patients receiving full-dose irradiation and 6 weekly p.o. doses of misonidazole, a phase III trial was carried out from '79-'83. Three hundred and six patients were entered, 42% of whom had oropharyngeal primaries and with 78% of all cases representing T3 or T4 (inoperable) lesions. Only 16% of the entire series presented with N0 necks. Fractionation was altered among the misonidazole-receiving patients, in contrast to standard 5 treatments per week among control patients, such that 2 separate treatments were given on each day of p.o. misonidazole administration (2.0 gm/m2/wk X 6 doses, 2.5 Gy in a.m., 2.1 Gy in p.m.). Total tumor doses were identical among the two treatment arms except that a limitation of 40.0 Gy to spinal cord was specified for sensitized radiotherapy vs. 45.0 Gy for control patients. Primary tumor clearance was observed to be 55-60%, with minor variations according to tumor stage and site. The local regional control rate among radiotherapy-alone patients was 26% at 2 years compared to 22% (2 years) within the misonidazole-receiving group. Analysis of survival revealed no advantage to the sensitized patients, with 55 +/- 2% surviving 1 year and 22 +/- 1% living 3 years following treatment in both treatment categories. Distant metastases as first site of failure (12-13%) and the local failure among initial complete responders (46%) showed no advantage to the misonidazole group. Although a misonidazole dosage of 2.0 gm/m2/wk X 6 (12 gm/m2 total) is well tolerated, no clinical benefit was demonstrated in this randomized trial

  15. Role of positron emission tomography-computed tomography in endometrial cancer

    Science.gov (United States)

    Erdemoğlu, Evrim; Çerçi, Sevim Süreyya; Erdemoğlu, Ebru; Yalçın, Yakup; Tatar, Burak

    2017-01-01

    Objective: The efficacy of preoperative 18F-fluoro-D-glucose (18F-FDG) positron emission tomography-computed tomography (PET-CT) in endometrium cancer is controversial. We examined the efficacy of PET-CT and the association between maximum standardized uptake value (SUVmax) and prognostic factors in endometrial cancer. Materials and Methods: Thirty patients with endometrial cancer underwent preoperative 18F-FDG/PET-CT. The patients were treated with abdominal hysterectomy with bilateral salpingo-oophorectomy, and bilateral systemic pelvic lymphadenectomy was planned for all patients; paraaortic lymphadenectomy was performed in patients with intermediate and high risk. Tumor histology, grade, depth of myometrial invasion, maximum tumor diameter, lymphovascular invasion, nodal status, and ovarian/adnexal metastases were recorded. Results: The mean primary tumor diameter was reported smaller in PET-CT and the effect size of PET-CT was -0.60. The kappa value was 0.06 for myometrial invasion. Pelvic lymph node metastasis was reported in 22.2% of patients in PET-CT. However, 3.7% of patients had pelvic lymph node metastasis. The kappa value for pelvic lymph node metastasis was 0.23, and sensitivity, specificity, and positive and negative predictive values were 100%, 80.7%, 16.6%, and 100%, respectively. Paraaortic lymph node metastasis in PET-CT was suspected in 10%. However, paraaortic lymph node metastasis was found in 6.7% in histopathologic analyses. The kappa value was 0.15. The sensitivity, specificity, and positive and negative predictive values of PET-CT for detecting paraaortic lymph node metastases were 100%, 93.7%, 66.6%, and 100%, respectively. Myometrial invasion and tumor diameter were the only important prognostic factors affecting SUVmax. Conclusion: According to our results, PET-CT has a limited role and diagnostic efficacy in endometrial cancer. The indications of FDG/PET-CT in endometrium cancer should be studied further and revised. PMID:29379661

  16. False Positive 18F-FDG Uptake in Mediastinal Lymph Nodes Detected with Positron Emission Tomography in Breast Cancer: A Case Report

    Directory of Open Access Journals (Sweden)

    Gamze Uğurluer

    2013-01-01

    Full Text Available Breast cancer is the most frequently diagnosed cancer among females. It is accepted that lymph node involvement with metastatic tumor and the presence of distant metastasis are the most important prognostic factors. Accurate staging is important in determining prognosis and appropriate treatment. Positron emission tomography with computed tomography detects malignancies using 2-[18F]-fluoro-2-deoxy-d-glucose (18F-FDG PET CT with high accuracy and they contribute to decisions regarding diagnosis, staging, recurrence, and treatment response. Here, we report a case of false positive metastatic mediastinal lymph nodes that were diagnosed by 18F-FDG PET CT in a 40-year-old breast cancer patient who had undergone preoperative evaluation. Right paratracheal, prevascular, aorticopulmonary, precarinal, subcarinal, hilar, and subhilar multiple conglomerated mediastinal lymph nodes were revealed in addition to left breast mass and axillary lymph nodes. Mediastinoscopy was performed with biopsy and pathology was reported as granulomatous lymphadenitis. In conclusion, any abnormal FDG accumulation in unusual lymph nodes must be evaluated carefully and confirmed histopathologically.

  17. Positron Emission Tomography in Prostate Cancer: Summary of Systematic Reviews and Meta-Analysis.

    Science.gov (United States)

    Jadvar, Hossein

    2015-09-01

    Prostate cancer is a prevalent public health problem worldwide. Over the past decade, there has been tremendous research activity in the potential use of positron emission tomography with a number of radiotracers targeted to various biological aspects of this complex tumor. Systematic reviews and meta-analysis are important contributions to the relevant literature that summarize the evidence while reducing the effect of various sources of bias in the published data. The accumulation of relevant data in this clinical setting has recently provided the opportunity for systematic reviews. In this brief article, I summarize the published systematic reviews and meta-analysis of positron emission tomography in prostate cancer. Most robust evidence suggests a probable role for first-line use of positron emission tomography with radiolabeled choline in restating patients with biochemical relapse of prostate cancer with the diagnostic performance that appears to be positively associated with the serum prostate specific antigen level and velocity. Future systematic reviews will be needed for other emerging radiotracers such as those based on prostate specific membrane antigen and gastrin-releasing peptide receptor.

  18. Application of positron emission tomography in the heart

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    This report discusses experimental and clinical applications of positron emission tomography to the heart, including measurements of blood flow to the myocardium and studies of metabolism and experimental injury. Most initial clinical studies have concentrated on ischemic heart disease, but the technique also has potential for investigation of cardiomyopathies, studying the neural control of the heart, and evaluating the effects of drugs on cardiac tissues

  19. Physiopathology of ischemic strokes: the input of positron emission tomography

    International Nuclear Information System (INIS)

    Steinling, M.; Samson, Y.

    1999-01-01

    The tomography by positrons emissions has brought essential physiological and pathological knowledge relative to cerebral vascular accidents in the acute phase, because it is possible to measure the cerebral blood flow, the oxygen extraction rate and the local oxygen consumption. (N.C.)

  20. Positron Emission Tomography: Its 65 years

    International Nuclear Information System (INIS)

    Del Guerra, A.; Belcari, N.; Bisogni, M.

    2016-01-01

    Positron Emission Tomography (PET) is a well-established imaging technique for in vivo molecular imaging. In this review after a brief history of PET there are presented its physical principles and the technology that has been developed for bringing PET from a bench experiment to a clinical indispensable instrument. The limitations and performance of the PET tomographs are discussed, both as for the hardware and software aspects. The status of art of clinical, preclinical and hybrid scanners (i.e., PET/CT and PET/MR) is reported. Finally the actual trend and the recent and future technological developments are fully illustrated.

  1. Simple noninvasive quantification method for measuring myocardial glucose utilization in humans employing positron emission tomography and fluorine-18 deoxyglucose

    International Nuclear Information System (INIS)

    Gambhir, S.S.; Schwaiger, M.; Huang, S.C.; Krivokapich, J.; Schelbert, H.R.; Nienaber, C.A.; Phelps, M.E.

    1989-01-01

    To estimate regional myocardial glucose utilization (rMGU) with positron emission tomography (PET) and 2-[ 18 F]fluoro-2-deoxy-D-glucose (FDG) in humans, we studied a method which simplifies the experimental procedure and is computationally efficient. This imaging approach uses a blood time-activity curve derived from a region of interest (ROI) drawn over dynamic PET images of the left ventricle (LV), and a Patlak graphic analysis. The spillover of radioactivity from the cardiac chambers to the myocardium is automatically removed by this analysis. Estimates of rMGU were obtained from FDG PET cardiac studies of six normal human subjects. Results from this study indicate that the FDG time-activity curve obtained from the LV ROI matched well with the arterial plasma curve. The rMGU obtained by Patlak graphic analysis was in good agreement with direct curve fitting results (r = 0.90). The average standard error of the estimate of the Patlak rMGU was low (3%). These results demonstrate the practical usefulness of a simplified method for the estimation of rMGU in humans by PET. This approach is noninvasive, computationally fast, and highly suited for developing parametric images of myocardial glucose utilization rate

  2. Positron Emission Tomography imaging with the SmartPET system

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, R.J. [Department of Physics, University of Liverpool, Liverpool, Merseyside L69 7ZE (United Kingdom)], E-mail: cooperrj@ornl.gov; Boston, A.J.; Boston, H.C.; Cresswell, J.R.; Grint, A.N.; Harkness, L.J.; Nolan, P.J.; Oxley, D.C.; Scraggs, D.P.; Mather, A.R. [Department of Physics, University of Liverpool, Liverpool, Merseyside L69 7ZE (United Kingdom); Lazarus, I.; Simpson, J. [STFC Daresbury Laboratory, Daresbury, Warrington, Cheshire WA4 4AD (United Kingdom)

    2009-07-21

    The Small Animal Reconstruction Tomograph for Positron Emission Tomography (SmartPET) project is the development of a small animal Positron Emission Tomography (PET) demonstrator based on the use of High-Purity Germanium (HPGe) detectors and state of the art digital electronics. The experimental results presented demonstrate the current performance of this unique system. By performing high precision measurements of one of the SmartPET HPGe detectors with a range of finely collimated gamma-ray beams the response of the detector as a function of gamma-ray interaction position has been quantified, facilitating the development of parametric Pulse Shape Analysis (PSA) techniques and algorithms for the correction of imperfections in detector performance. These algorithms have then been applied to data from PET imaging measurements using two such detectors in conjunction with a specially designed rotating gantry. In this paper we show how the use of parametric PSA approaches allows over 60% of coincident events to be processed and how the nature and complexity of an event has direct implications for the quality of the resulting image.

  3. Myocardial glucose metabolism assessed by positron emission tomography and the histopathologic findings of microvessels in syndrome X

    International Nuclear Information System (INIS)

    Satake, Osamichi; Kajinami, Kouji; Ishikawa, Yoshimaro; Ueda, Tadashi; Tsugawa, Hiroichi; Kanemitsu, Seiyu; Okubo, Shinji; Takekoshi, Noboru

    2004-01-01

    Syndrome X has been recognized as a disease that is primarily reflected in the cardiac microvasculature. Myocardial metabolism in this condition has been studied, but not in relation to small vessel pathology. In order to examine the relationship between myocardial metabolism and small vessel pathology, 24 consecutive patients with syndrome X (7 men, 17 women; mean age 58 years) were evaluated by the thallium exercise stress test, positron emission tomography using F-18 fluoro-deoxyglucose (FDG), and an endomyocardial biopsy. All patients showed either diffuse or focal increase in the myocardial uptake of FDG, but only 17 patients (71%) showed hypoperfused areas with partial or complete redistribution in the thallium study. Quantification of myocardial FDG uptake revealed that the value in syndrome X patients was 10-fold higher than in controls (p<0.0001). Histopathological examination revealed that in syndrome X there is an extensive increase in smooth muscle cells and thickening of the vascular wall, even in capillary vessels, and the small vessel lumen was markedly narrowed. There was a significant inverse correlation between FDG myocardial uptake and the microvessel luminal area. In syndrome X patients, myocardial FDG uptake is increased extensively, which is strongly associated with narrowed myocardial microvasculature. (author)

  4. Low-energy positron and electron diffraction and positron-stimulated secondary electron emission from Cu(100)

    International Nuclear Information System (INIS)

    Weiss, A.H.

    1983-01-01

    The results of two series of experiments are reported. In the first, an electrostatically guided beam of low-energy (40-400 eV) positrons, delta/sub p/ was used to study low-energy positron diffraction (LEPD) from a Cu(100) surface under ultrahigh-vacuum conditions. Low-energy electron diffraction (LEED) data were obtained from the same sample in the same apparatus. Comparison of LEPD and LEED intensity versus energy data with model calculations made using computer programs developed by C.B. Duke and collaborators indicated that: LEPD data is adequately modeled using potentials with no exchange-correlation term. The inelastic mean free path, lambda/sub ee/, is shorter for positrons than for electrons at low (< approx.80 eV). LEED is better than LEPD at making a determination of the first-layer spacing of Cu(100) for the particular data set reported. In the second set of experiments, the same apparatus and sample were used to compare positron- and electron-stimulated secondary-electron emission (PSSEE and ESSEE). The results were found to be consistent with existing models of secondary-electron production for metals. The energy distributions of secondary-electrons had broad low-energy (<10 eV) peaks for both positron and electron stimulation. But the PSEE distribution showed no elastic peak. Measurements of secondary-electron angular distributions, found to be cosine-like in both the PSSEE and ESSEE case, were used to obtain total secondary yield ratios, delta, at four beam energies ranging from 40-400 eV. The secondary yield ratio for primary positrons and the yield for primary electrons, delta/sub e/, were similar at these energies. For 400-eV primary particles the secondary yields were found to be delta/sub p/ = 0.94 +/- 0.12 and delta/sub e/ = 0.94 +/- 0./12, giving a ratio of unity for positron-stimulated secondary yield to electron-stimulated secondary yield

  5. Carbon-11 and fluorine-18 chemistry devoted to molecular probes for imaging the brain with positron emission tomography.

    Science.gov (United States)

    Dollé, Frédéric

    2013-01-01

    Exploration of the living human brain in real-time and in a noninvasive way was for centuries only a dream, made, however, possible today with the remarkable development during the four last decades of powerful molecular imaging techniques, and especially positron emission tomography (PET). Molecular PET imaging relies, from a chemical point of view, on the use and preparation of a positron-emitting radiolabelled probe or radiotracer, notably compounds incorporating one of two short-lived radionuclides fluorine-18 (T1/2 : 109.8 min) and carbon-11 (T1/2 : 20.38 min). The growing availability and interest for the radiohalogen fluorine-18 in radiopharmaceutical chemistry undoubtedly results from its convenient half-life and the successful use in clinical oncology of 2-[(18) F]fluoro-2-deoxy-d-glucose ([(18) F]FDG). The special interest of carbon-11 is not only that carbon is present in virtually all biomolecules and drugs allowing therefore for isotopic labelling of their chemical structures but also that a given molecule could be radiolabelled at different functions or sites, permitting to explore (or to take advantage of) in vivo metabolic pathways. PET chemistry includes production of these short-lived radioactive isotopes via nuclear transmutation reactions using a cyclotron, and is directed towards the development of rapid synthetic methods, at the trace level, for the introduction of these nuclides into a molecule, as well as the use of fast purification, analysis and formulation techniques. PET chemistry is the driving force in molecular PET imaging, and this special issue of the Journal of Labelled Compounds and Radiopharmaceuticals, which is strongly chemistry and radiochemistry-oriented, aims at illustrating, be it in part only, the state-of-the-art arsenal of reactions currently available and its potential for the research and development of specific molecular probes labelled with the positron emitters carbon-11 and fluorine-18, with optimal imaging

  6. Contribution of positron emission tomography in pleural disease.

    OpenAIRE

    Duysinx, Bernard; Corhay, Jean-Louis; Larock, Marie-Paule; Withofs, Nadia; Bury, Thierry; Hustinx, Roland; Louis, Renaud

    2010-01-01

    INTRODUCTION: Positron emission tomography (PET) now plays a clear role in oncology, especially in chest tumours. We discuss the value of metabolic imaging in characterising pleural pathology in the light of our own experience and review the literature. BACKGROUND: PET is particularly useful in characterising malignant pleural pathologies and is a factor of prognosis in mesothelioma. Metabolic imaging also provides clinical information for staging lung cancer, in researching the primary tumou...

  7. Positron emission tomography and migraine

    International Nuclear Information System (INIS)

    Chabriat, H.

    1992-01-01

    Positron emission tomography (PET) is a brain imaging technique that allows in vivo studies of numerous physiological parameters. There have been few PET studies in migraine patients. Cerebral blood flow changes with no variations in brain oxygen consumption have been reported in patients with prolonged neurologic manifestations during migraine attacks. Parenteral administration of reserpine during migraine headache has been followed by a fall in the overall cerebral uptake of glucose. The small sample sizes and a number of methodologic problems complicate the interpretation of these results. Recent technical advances and the development of new PET tracers can be expected to provide further insight into the pathophysiology of migraine. Today cerebral cortex 5 HT 2 serotonin receptors can be studied in migraine patients with PET

  8. Detectors, sampling, shielding, and electronics for positron emission tomography

    International Nuclear Information System (INIS)

    Derenzo, S.E.

    1981-08-01

    A brief discussion of the important design elements for positron emission tomographs is presented. The conclusions are that the instrumentation can be improved by the use of larger numbers of small, efficient detectors closely packed in many rings, the development of new detector materials, and novel electronic designs to reduce the deadtime and increase maximum event rates

  9. Novel targets for positron emission tomography (PET) radiopharmaceutical tracers for visualization of neuroinflammation

    Science.gov (United States)

    Shchepetkin, I.; Shvedova, M.; Anfinogenova, Y.; Litvak, M.; Atochin, D.

    2017-08-01

    Non-invasive molecular imaging techniques can enhance diagnosis of neurological diseases to achieve their successful treatment. Positron emission tomography (PET) imaging can identify activated microglia and provide detailed functional information based on molecular biology. This imaging modality is based on detection of isotope labeled tracers, which emit positrons. The review summarizes the developments of various radiolabeled ligands for PET imaging of neuroinflammation.

  10. Neural correlates of sensorimotor gating: A metabolic positron emission tomography study in awake rats

    Directory of Open Access Journals (Sweden)

    Cathrin eRohleder

    2014-05-01

    Full Text Available Impaired sensorimotor gating occurs in neuropsychiatric disorders such as schizophrenia and can be measured using the prepulse inhibition (PPI paradigm of the acoustic startle response. This assay is frequently used to validate animal models of neuropsychiatric disorders and to explore the therapeutic potential of new drugs. The underlying neural network of PPI has been extensively studied with invasive methods and genetic modifications. However, its relevance for healthy untreated animals and the functional interplay between startle- and PPI-related areas during a PPI session is so far unknown. Therefore, we studied awake rats in a PPI paradigm, startle control and background noise control, combined with behavioral [18F]fluoro-2-deoxyglucose positron emission tomography (FDG-PET. Subtractive analyses between conditions were used to identify brain regions involved in startle and PPI processing in well-hearing Black hooded rats. For correlative analysis with regard to the amount of PPI we also included hearing-impaired Lister hooded rats that startled more often, because their hearing threshold was just below the lowest prepulses. Metabolic imaging showed that the brain areas proposed for startle and PPI mediation are active during PPI paradigms in healthy untreated rats. More importantly, we show for the first time that the whole PPI modulation network is active during passive PPI sessions, where no selective attention to prepulse or startle stimulus is required. We conclude that this reflects ongoing monitoring of stimulus significance and constant adjustment of sensorimotor gating.

  11. Role and impact of [18F]-fluorodeoxyglucose positron emission tomography in recurrent breast cancer

    International Nuclear Information System (INIS)

    Grahek, D.; Montravers, F.; Aide, N.; Kerrou, K.; Talbot, J.N.

    2004-01-01

    [18F]-fluorodeoxyglucose positron emission tomography is widely used in oncology to detect malignant tissue, assess the extent of the disease and follow up treatment. In breast cancer, recurrence detection seems to be the leading indication of [18F] fluorodeoxyglucose positron emission tomography. This review, including recent publications, aims to evaluate its role to detect the recurrent malignant. tissue when tumour marker levels are isolatedly rising and to evaluate the extent of-the disease. The first impact studies reveal its important role in the management of the patients suspected of breast cancer recurrence. (author)

  12. Study of the effect of misonidazole in conjunction with radiotherapy for the treatment of head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Henk, J.M.; Adams, G.E.; Ash, D. (Medical Research Council, London (UK))

    1984-07-01

    The effect of the hypoxic cell sensitiser misonidazole as an adjuvant to radiotherapy of head and neck cancer was tested in a randomised double blind study. Patients with squamous carcinoma of the upper alimentary and respiratory tract, excluding those with early disease with good prognosis, who were deemed suitable for radical radiotherapy and fit to receive the drug were entered. Two radiotherapy regimes were employed, 10 fractions in 3 weeks to a modal tumour dose of 4000-4500 cGy, and 20 fractions in 4 weeks to a modal tumour dose of 5000-5750 cGy. Participating radiotherapists opted for one of the schemes. Misonidazole or placebo capsules were administered 4 to 5 hours before each fraction of radiotherapy to a total of 11 to 13 g/m/sup 2/. 168 patients were treated with 10 fractions and 99 with 20 fractions, between March 1979 and November 1981, when entry was stopped because of the high incidence of drug toxicity and lack of benefit. The estimated hazard ratio for local control was 0.89, indicating a slight advantage to misonidazole, statistically insignificant (p = 0.5). Peripheral neuropathy occurred in 56 patients receiving misonidazole, and was more severe when treatment was given in 10 fractions.

  13. Simulated annealing image reconstruction for positron emission tomography

    International Nuclear Information System (INIS)

    Sundermann, E.; Lemahieu, I.; Desmedt, P.

    1994-01-01

    In Positron Emission Tomography (PET) images have to be reconstructed from moisy projection data. The noise on the PET data can be modeled by a Poison distribution. In this paper, we present the results of using the simulated annealing technique to reconstruct PET images. Various parameter settings of the simulated annealing algorithm are discussed and optimized. The reconstructed images are of good quality and high contrast, in comparison to other reconstruction techniques. (authors)

  14. MR imaging and positron emission tomography of cortical heterotopia

    Energy Technology Data Exchange (ETDEWEB)

    Bairamian, D.; Di Chiro, G.; Theodore, W.H.; Holmes, M.D.; Dorwart, R.H.; Larson, S.M.

    1985-11-01

    Heterotopia of the gray matter is a developmental malformation in which ectopic cortex is found in the white matter of the brain. A case of a 33-year-old man with cortical heterotopia who had a lifelong history of seizures and psychomotor retardation is reported, including the results of cerebral CT, magnetic resonance imaging, and positron emission tomography using YF-2-deoxyglucose.

  15. MR imaging and positron emission tomography of cortical heterotopia

    International Nuclear Information System (INIS)

    Bairamian, D.; Di Chiro, G.; Theodore, W.H.; Holmes, M.D.; Dorwart, R.H.; Larson, S.M.

    1985-01-01

    Heterotopia of the gray matter is a developmental malformation in which ectopic cortex is found in the white matter of the brain. A case of a 33-year-old man with cortical heterotopia who had a lifelong history of seizures and psychomotor retardation is reported, including the results of cerebral CT, magnetic resonance imaging, and positron emission tomography using 18 F-2-deoxyglucose

  16. Positron emission tomography camera

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    A positron emission tomography camera having a plurality of detector planes positioned side-by-side around a patient area to detect radiation. Each plane includes a plurality of photomultiplier tubes and at least two rows of scintillation crystals on each photomultiplier tube extend across to adjacent photomultiplier tubes for detecting radiation from the patient area. Each row of crystals on each photomultiplier tube is offset from the other rows of crystals, and the area of each crystal on each tube in each row is different than the area of the crystals on the tube in other rows for detecting which crystal is actuated and allowing the detector to detect more inter-plane slides. The crystals are offset by an amount equal to the length of the crystal divided by the number of rows. The rows of crystals on opposite sides of the patient may be rotated 90 degrees relative to each other

  17. Measurement of regional cerebral glucose utilization in man by positron emission tomography

    International Nuclear Information System (INIS)

    Baron, J.C.

    1986-05-01

    The various methods available for the study of regional cerebral glucose consumption in man by positron emission tomography are described and their applications, limitations and principal physiopathological results are presented [fr

  18. Positron emission tomography of FDG in schizophrenia

    International Nuclear Information System (INIS)

    Sargent, T. III; Kusubov, N.

    1986-01-01

    The use of the Donner dynamic positron emission tomograph to study fluorodeoxyglucose labelled 18 F uptake in the brain of six patients with schizophrenia is reported. The glucose metabolic rate and the local cerebral metabolic rate were calculated. The dynamic brain uptake data and the blood input function were used to calculate rate constants by an iterative least squares fitting program for all regions of interest chosen in the brain. Although the number of patients was small, differences in k3 were statistically significant in several brain regions compared with normal controls

  19. Is there any role of positron emission tomography computed tomography for predicting resectability of gallbladder cancer?

    Science.gov (United States)

    Kim, Jaihwan; Ryu, Ji Kon; Kim, Chulhan; Paeng, Jin Chul; Kim, Yong-Tae

    2014-05-01

    The role of integrated (18)F-2-fluoro-2-deoxy-D-glucose positron emission tomography computed tomography (PET-CT) is uncertain in gallbladder cancer. The aim of this study was to show the role of PET-CT in gallbladder cancer patients. Fifty-three patients with gallbladder cancer underwent preoperative computed tomography (CT) and PET-CT scans. Their medical records were retrospectively reviewed. Twenty-six patients underwent resection. Based on the final outcomes, PET-CT was in good agreement (0.61 to 0.80) with resectability whereas CT was in acceptable agreement (0.41 to 0.60) with resectability. When the diagnostic accuracy of the predictions for resectability was calculated with the ROC curve, the accuracy of PET-CT was higher than that of CT in patients who underwent surgical resection (P=0.03), however, there was no difference with all patients (P=0.12). CT and PET-CT had a discrepancy in assessing curative resection in nine patients. These consisted of two false negative and four false positive CT results (11.3%) and three false negative PET-CT results (5.1%). PET-CT was in good agreement with the final outcomes compared to CT. As a complementary role of PEC-CT to CT, PET-CT tended to show better prediction about resectability than CT, especially due to unexpected distant metastasis.

  20. Quantification of mu and non-mu opiate receptors in temporal lobe epilepsy using positron emission tomography.

    Science.gov (United States)

    Mayberg, H S; Sadzot, B; Meltzer, C C; Fisher, R S; Lesser, R P; Dannals, R F; Lever, J R; Wilson, A A; Ravert, H T; Wagner, H N

    1991-07-01

    Alterations in a variety of neurotransmitter systems have been identified in experimental models of epilepsy and in brain tissue from patients with intractable temporal lobe seizures. The availability of new high-affinity radioligands permits the study of some neuroreceptors in vivo with positron emission tomography (PET). We previously characterized the in vivo binding of 11C-carfentanil, a potent and selective mu opiate receptor agonist, and described increases in 11C-carfentanil binding in the temporal neocortex of patients with unilateral temporal lobe epilepsy. These studies have been extended to 11C-diprenorphine, which labels mu, kappa, and delta opiate receptor subtypes. Paired measurements of opiate receptor binding were performed with PET using 11C-carfentanil and 11C-diprenorphine in patients with unilateral temporal lobe seizures. Carfentanil binding, reflecting changes in mu opiate receptors, was increased in the temporal neocortex and decreased in the amygdala on the side of the epileptic focus. Diprenorphine binding, reflecting mu as well as non-mu opiate subtypes, was not significantly different among regions in the focus and nonfocus temporal lobes. Regional glucose metabolism, measured using 18F-2-fluoro-2-deoxyglucose, was decreased in the mesial and lateral aspects of the temporal lobe ipsilateral to the epileptogenic focus. The variation in pattern of carfentanil and diprenorphine binding supports a differential regulation of opiate subtypes in unilateral temporal lobe epilepsy.

  1. Evaluation of carbohydrate cardiac metabolism by the 18FDG and positron emission tomography in the myocardial infarction with healthy coronaries

    International Nuclear Information System (INIS)

    Agostini, D.; Quennelle, F.; Babatasi, G.; Grollier, G.; Potier, J.C.; Bouvard, G.

    1997-01-01

    The aim of this study was to evaluate the regional myocardial metabolism of glucose (RMMG) by positron emission tomography (PET) with fluoro-de-oxy-glucose ( 18 FDG) in patients having myocardial infarction with healthy coronaries (MIHC). Four patients (4M, age: 41 ± 12 years) have presented: MI with a coronarography showing no significant lesions on the epicardial arteries, an irreversible anterior hypo-perfusion, moderated at 201 Tl scintigraphy and an isotopic FEVG 18 FDG. The dynamical images allow measuring RMMG and the static image to define the regions of interest on ventricular transaxial cross sections. A myocardial region embodying the totality of VG, including the septal, anterior and lateral regions and an intracavitary region are handy delimited. A model with 3 compartments is applied to the time-activity curves measured in the VG (input function) and in the myocardium (Patlak's method) and allows measuring the RMMG. The mean value of RMMG, measured along the VG, is significantly diminished as compared with that measured in healthy subjects. In conclusion, the PET based on 18 FDG shows that the myocardial carbohydrate metabolism is altered in patients afflicted with MIHC

  2. Investigating Serotonergic Function Using Positron Emission Tomography: Overview and Recent Findings

    NARCIS (Netherlands)

    Veltman, D.J.; Ruhe, H.G.; Booij, J.

    2010-01-01

    Mono-aminergic neurotransmitters, in particular serotonin (5-HT), are involved in regulating a large number of psychological and physiological functions, and abnormal 5-HT transmission has been implicated in a wide variety of neuropsychiatric disorders. Positron emission tomography (PET) is a

  3. Readout of scintillator light with avalanche photodiodes for positron emission tomography

    International Nuclear Information System (INIS)

    Chen, Ruru; Fremout, A.; Tavernier, S.; Bruyndonckx, P.; Clement, D.; Loude, J.-F.; Morel, C.

    1999-01-01

    The noise properties and other relevant characteristics of avalanche photodiodes have been investigated with the perspective of replacing photomultiplier tubes in positron emission tomography. It is clearly demonstrated that they are a valid alternative to photomultiplier tubes in this application

  4. Time-of-flight positron emission tomography using optical fiber circuit

    International Nuclear Information System (INIS)

    Yamawaki, Masato; Katsumura, Yousuke; Suzuki, Takenori

    2008-01-01

    The measurement method and system architecture of a new time-of-flight positron emission tomography (TOF-PET) system are proposed. This system collects scintillation light using optical fibers connected directly to scintillators and measures the position of positron annihilation. Many scintillators are placed cylindrically whereby a pair of scintillators detects a pair of γ-rays generated at the positron annihilation point. Optical fiber circuits, most of which are bundles of optical fibers bound clockwise or counterclockwise around the cylinder of scintillators, collect light signals generated by γ-rays. These light signals are amplified by several photomultiplier tubes and processed using a single digital oscilloscope to determine the TOF of the positron annihilation γ-rays. One of the most important factors in the performance of the TOF-PET system is the TOF resolution. When fiber circuits are used for transmitting light signals, the dispersion of light signals and the decrease in light intensity are the major factors in the deterioration of the TOF resolution. The result of the preliminary experiment leads to the conclusion that the use of optical fibers degrades the intensity of light but does not severely degrade the TOF resolution. (author)

  5. Measurement of absolute bone blood flow by positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nahmias, C.; Cockshott, W.P.; Garnett, E.S.; Belbeck, L.W.

    1986-03-01

    A method of measuring bone blood flow has been developed using /sup 18/F sodium fluoride and positron emission tomography. The blood flow levels are in line with those obtained experimentally from microsphere embolisation. This investigative method could be applied to elucidate a number of clinical questions involving bone perfusion.

  6. Improved positron emission tomography camera

    International Nuclear Information System (INIS)

    Mullani, N.A.

    1986-01-01

    A positron emission tomography camera having a plurality of rings of detectors positioned side-by-side or offset by one-half of the detector cross section around a patient area to detect radiation therefrom, and a plurality of scintillation crystals positioned relative to the photomultiplier tubes whereby each tube is responsive to more than one crystal. Each alternate crystal in the ring may be offset by one-half or less of the thickness of the crystal such that the staggered crystals are seen by more than one photomultiplier tube. This sharing of crystals and photomultiplier tubes allows identification of the staggered crystal and the use of smaller detectors shared by larger photomultiplier tubes thereby requiring less photomultiplier tubes, creating more scanning slices, providing better data sampling, and reducing the cost of the camera. (author)

  7. The Positron Emission Tomography. A diagnostic technique

    International Nuclear Information System (INIS)

    Salvadori, P.

    2001-01-01

    Positron Emission Tomography (PET) is a new imaging modality, which is able to assess non-invasively the biochemical mechanisms, underlying physiological and pathophysiological processes in vivo in humans. The technique relies on the administration of radioactive tracers labeled with short-lived positron emitters, which need to be produced on site via a particle accelerator (cyclotron). Radionuclides are produced upon request and formulated into biologically active organic molecules having precise pharmacokinetics and specificity. The radiotracer can be detected by the PET scanner and represented as tomographic sections (images of body sections) showing its regional distribution and concentration. This makes it possible to address clinical questions concerning occurrence and evolution of many diseases as well as their response to therapy. The ability to image (measure) biological processes and not only anatomy enables PET to explore diseases in the very early stage, including those diseases which are not related to modifications of organ structure (e.g. psychiatric diseases, metabolic disorders, biochemical disfunction). PET plays a major role, in conjunction with the other imaging modalities, to improve diagnosis capabilities and disease mechanism understanding [it

  8. Positron emission tomography in the evaluation of subdural hematomas

    International Nuclear Information System (INIS)

    Ericson, K.; Bergstroem, M.; Eriksson, L.

    1980-01-01

    Fifteen patients with 21 subdural effusions were investigated both with transmission computer assisted tomography (CAT) and positron emission tomography (PET). The tracer in the emission studies was 68 Ga-EDTA. Twelve lesions were visualized both with CAT and PET. Five lesions that were negative or doubtful on CAT were visualized with PET, whereas four lesions negative or doubtful on PET were demonstrated by CAT. The two methods complement each other due to the fact that they are based on different mechanisms: CAT mainly on attenuation of the fluid collection. PET on isotope accumulation, particularly in the hematoma membranes

  9. Emission computed tomography: methodology and applications

    International Nuclear Information System (INIS)

    Reivich, M.; Alavi, A.; Greenberg, J.; Fowler, J.; Christman, D.; Rosenquist, A.; Rintelmann, W.; Hand, P.; MacGregor, R.; Wolf, A.

    1980-01-01

    A technique for the determination of local cerebral glucose metabolism using positron emission computed tomography is described as an example of the development of use of this methodology for the study of these parameters in man. The method for the determination of local cerebral glucose metabolism utilizes 18 F-2-fluoro-2-deoxyglucose ([ 18 F]-FDG). In this method [ 18 F]-FDG is used as a tracer for the exchange of glucose between plasma and brain and its phosphorylation by hexokinase in the tissue. The labelled product of metabolism, [ 18 F]-FDG phosphate, is essentially trapped in the tissue over the time course of the measurement. The studies demonstrate the potential usefulness of emission computed tomography for the measurement of various biochemical and physiological parameters in man. (Auth.)

  10. Simulated annealing image reconstruction for positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sundermann, E; Lemahieu, I; Desmedt, P [Department of Electronics and Information Systems, University of Ghent, St. Pietersnieuwstraat 41, B-9000 Ghent, Belgium (Belgium)

    1994-12-31

    In Positron Emission Tomography (PET) images have to be reconstructed from moisy projection data. The noise on the PET data can be modeled by a Poison distribution. In this paper, we present the results of using the simulated annealing technique to reconstruct PET images. Various parameter settings of the simulated annealing algorithm are discussed and optimized. The reconstructed images are of good quality and high contrast, in comparison to other reconstruction techniques. (authors). 11 refs., 2 figs.

  11. Detectors for high resolution dynamic positron emission tomography

    International Nuclear Information System (INIS)

    Derenzo, S.E.; Budinger, T.F.; Huesman, R.H.

    1985-01-01

    Tomography is the technique of producing a photographic image of an opaque specimen by transmitting a beam of x-rays or gamma rays through the specimen onto an adjacent photographic film. The image results from variations in thickness, density, and chemical composition, of the specimen. This technique is used to study the metabolism of the human brain. This article examines the design of equipment used for high resolution dynamic positron emission tomography. 27 references, 5 figures, 3 tables

  12. The electronics system for the LBNL positron emission mammography (PEM) camera

    CERN Document Server

    Moses, W W; Baker, K; Jones, W; Lenox, M; Ho, M H; Weng, M

    2001-01-01

    Describes the electronics for a high-performance positron emission mammography (PEM) camera. It is based on the electronics for a human brain positron emission tomography (PET) camera (the Siemens/CTI HRRT), modified to use a detector module that incorporates a photodiode (PD) array. An application-specified integrated circuit (ASIC) services the photodetector (PD) array, amplifying its signal and identifying the crystal of interaction. Another ASIC services the photomultiplier tube (PMT), measuring its output and providing a timing signal. Field-programmable gate arrays (FPGAs) and lookup RAMs are used to apply crystal-by-crystal correction factors and measure the energy deposit and the interaction depth (based on the PD/PMT ratio). Additional FPGAs provide event multiplexing, derandomization, coincidence detection, and real-time rebinning. Embedded PC/104 microprocessors provide communication, real-time control, and configure the system. Extensive use of FPGAs make the overall design extremely flexible, all...

  13. Positron emission tomography (PET) in psychiatry

    International Nuclear Information System (INIS)

    Buchsbaum, M.S.

    1984-01-01

    In the past the approach to the brain has been necessarily indirect, employing peripheral fluids to assess central and regional neurochemical processes. Blood, urine, skin and muscle biopsy, and cerebrospinal fluid are valuable reflectors of the neurochemical and neuropharmacological activity of the brain, but are removed in time and place from disordered thought processes and diluted by the products of both functional and dysfunctional brain systems. Biopsy studies have helped in studying the functional disorders of organs like the liver, but they are destructive to the brain and less useful because unlike these organs, the brain has a regional variation in its chemistry. The experimental insights from animal studies focusing on the pharmacology of individual cell groups - in striatum or locus coeruleus, for example - cannot easily or unambigiously be applied to clinical populations. Positron emission tomography (PET) is a versatile approach utilizing the mathematics of x-ray transmission scanning (CT scanning) to produce slice images of radioisotope distribution. PET makes possible a wide range of metabolic studies. Positron emitters such as carbon-11 or fluorine-18 can be used to label glucose, amino acids, drugs, neurotransmitter precursors, and many other molecules and examine their distribution and fate in discrete cell groups

  14. Measurement of brain pH with positron emission tomography

    International Nuclear Information System (INIS)

    Buxton, R.B.; Alpert, N.M.; Ackerman, R.H.; Wechsler, L.R.; Elmaleh, D.R.; Correia, J.A.

    1985-01-01

    With positron emission tomography (PET) it is now possible to measure local brain pH noninvasively in humans. The application of PET to the determination of pH is relatively new, so only a handful of papers on the subject have appeared in print. This chapter reviews the current strategies for measuring brain pH with PET, discuss methodological problems, and present initial results

  15. Regional myocardial blood flow, metabolism and function assessed noninvasively by positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Schelbert, H.R.; Phelps, M.E.; Hoffman, E.; Huang, S.; Kuhl, D.E.

    1979-01-01

    Positron emission computed tomography is a new technique for the noninvasive measure of myocardial blood flow, mechanical function and, in particular, metabolism. The capability of this new study means is due to the technological innovations of the imaging device and the availability of radioactive tracers that are specific for blood flow and metabolism. The device permits recording of cross-sectional images of the left ventricular myocardium that reflect quantitatively regional tracer tissue concentrations. By employing tracer kinetic models this new technique permits the measurement of regional glucose and fatty acid metabolism of the heart. While already an important new tool for investigative studies into cardiac physiology and pathophysiology, the clinical utility of positron emission tomography remains to be defined.

  16. Regional myocardial blood flow, metabolism and function assessed noninvasively by positron emission tomography

    International Nuclear Information System (INIS)

    Schelbert, H.R.; Phelps, M.E.; Hoffman, E.; Huang, S.; Kuhl, D.E.

    1979-01-01

    Positron emission computed tomography is a new technique for the noninvasive measure of myocardial blood flow, mechanical function and, in particular, metabolism. The capability of this new study means is due to the technological innovations of the imaging device and the availability of radioactive tracers that are specific for blood flow and metabolism. The device permits recording of cross-sectional images of the left ventricular myocardium that reflect quantitatively regional tracer tissue concentrations. By employing tracer kinetic models this new technique permits the measurement of regional glucose and fatty acid metabolism of the heart. While already an important new tool for investigative studies into cardiac physiology and pathophysiology, the clinical utility of positron emission tomography remains to be defined

  17. Investigation of granular impact using positron emission particle tracking

    KAUST Repository

    Marston, Jeremy O.

    2015-04-01

    We present results from an experimental study of granular impact using a combination of high-speed video and positron emission particle tracking (PEPT). The PEPT technique exploits the annihilation of photons from positron decay to determine the position of tracer particles either inside a small granular bed or attached to the object which impacts the bed. We use dense spheres as impactors and the granular beds are comprised of glass beads which are fluidised to achieve a range of different initial packing states. For the first time, we have simultaneously investigated both the trajectory of the sphere, the motion of particles in a 3-D granular bed and particles which jump into the resultant jet, which arises from the collapse of the cavity formed by the impacting sphere.

  18. X-ray-based attenuation correction for positron emission tomography/computed tomography scanners.

    Science.gov (United States)

    Kinahan, Paul E; Hasegawa, Bruce H; Beyer, Thomas

    2003-07-01

    A synergy of positron emission tomography (PET)/computed tomography (CT) scanners is the use of the CT data for x-ray-based attenuation correction of the PET emission data. Current methods of measuring transmission use positron sources, gamma-ray sources, or x-ray sources. Each of the types of transmission scans involves different trade-offs of noise versus bias, with positron transmission scans having the highest noise but lowest bias, whereas x-ray scans have negligible noise but the potential for increased quantitative errors. The use of x-ray-based attenuation correction, however, has other advantages, including a lack of bias introduced from post-injection transmission scanning, which is an important practical consideration for clinical scanners, as well as reduced scan times. The sensitivity of x-ray-based attenuation correction to artifacts and quantitative errors depends on the method of translating the CT image from the effective x-ray energy of approximately 70 keV to attenuation coefficients at the PET energy of 511 keV. These translation methods are usually based on segmentation and/or scaling techniques. Errors in the PET emission image arise from positional mismatches caused by patient motion or respiration differences between the PET and CT scans; incorrect calculation of attenuation coefficients for CT contrast agents or metallic implants; or keeping the patient's arms in the field of view, which leads to truncation and/or beam-hardening (or x-ray scatter) artifacts. Proper interpretation of PET emission images corrected for attenuation by using the CT image relies on an understanding of the potential artifacts. In cases where an artifact or bias is suspected, careful inspection of all three available images (CT and PET emission with and without attenuation correction) is recommended. Copyright 2003 Elsevier Inc. All rights reserved.

  19. Analysis of solute transport in plants using positron emission tomography

    International Nuclear Information System (INIS)

    Partelova, D.

    2016-01-01

    In the first part of the work, geometrically and radiochemically characterized standards (phantoms) imitating the plant tissues and allowing the exact quantification of visualised radioindicator in plant tissues were designed and prepared within the study of visual and analytical characteristics of used positron emission tomograph (microPET system) commercially developed for animal objects at visualization of thin objects. Individual experiments carried out by exposure of excised leaves of tobacco (Nicotiana tabacum L.) or radish (Raphanus sativus L.) in solutions of 2-deoxy-2-fluoro-D-glucose labelled with positron emitter 18 F (2-[ 18 F]FDG) containing 10-, 100-, or 1000-times higher concentrations of D-glucose (c glu ) in comparison with the original 2-[ 18 F]FDG solution showed that the significant changes in visualisation of 2-[ 18 F]FDG distribution as well as in chemical portion of 2-[ 18 F]FDG within the leaf blade were observed as result of increased c glu . In the experiments with the whole plants of tobacco or radish exposed in 2-[ 18 F]FDG solution through the root system, only minimal translocation of 18 F radioactivity into the above-ground parts of plants, also in the case of increased c glu , was observed, which suggest the role of root system as a selective barrier of 2-[ 18 F]FDG transport from roots to the above-ground parts. On the basis of mentioned knowledge and analytical approaches (application of prepared phantoms), the dynamic study of 2-[ 18 F]FDG uptake and transport within the excised leaf of tobacco or whole radish plant was carried out. The description of these processes was realized through the 3D PET images and through the quantification of 2-[ 18 F]FDG distribution within the chosen regions of interest from the point of view of accumulated 18 F radioactivity (in Bq) or amount of D-glucose (in μg) as well. Application of methods of multivariate analysis allows to found the similarities between studied objects mainly from the point

  20. Evaluation of response to immune checkpoint inhibitors: Is there a role for positron emission tomography?

    Institute of Scientific and Technical Information of China (English)

    Matteo Bauckneht; Roberta Piva; Gianmario Sambuceti; Francesco Grossi; Silvia Morbelli

    2017-01-01

    Strategies targeting intracellular negative regulators such as immune checkpoint inhibitors(ICPIs) have demonstrated significant antitumor activity across a wide range of solid tumors. In the clinical practice, the radiological effect of immunotherapeutic agents has raised several more relevant and complex challenges for the determination of their imaging-based response at single patient level. Accordingly, it has been suggested that the conventional Response Evaluation Criteria in Solid Tumors assessment alone, based on dimensional evaluation provided by computed tomography(CT), tends to underestimate the benefit of ICPIs at least in a subset of patients, supporting the need of immunerelated response criteria. Different from CT, very few data are available for the evaluation of immunotherapy by means of 18F-fluoro-2-deoxy-D-glucose positron emission tomography(FDG-PET). Moreover, since the antineoplastic activity of ICPIs is highly related to the activation of T cells against cancer cells, FDG accumulation might cause false-positive findings. Yet, discrimination between benign and malignant processes represents a huge challenge for FDG-PET in this clinical setting. Consequently, it might be of high interest to test the complex and variegated response to ICPIs by means of PET and thus it is worthwhile to ask if a similar introduction of immune-related PET-based criteria could be proposed in the future. Finally, PET might offer a new insight into the biology and pathophysiology of ICPIs thanks to a growing number of non-invasive immunediagnostic approaches based on non-FDG tracers.

  1. Fundamental limits of positron emission mammography

    International Nuclear Information System (INIS)

    Moses, William W.; Qi, Jinyi

    2001-01-01

    We explore the causes of performance limitation in positron emission mammography cameras. We compare two basic camera geometries containing the same volume of 511 keV photon detectors, one with a parallel plane geometry and another with a rectangular geometry. We find that both geometries have similar performance for the phantom imaged (in Monte Carlo simulation), even though the solid angle coverage of the rectangular camera is about 50 percent higher than the parallel plane camera. The reconstruction algorithm used significantly affects the resulting image; iterative methods significantly outperform the commonly used focal plane tomography. Finally, the characteristics of the tumor itself, specifically the absolute amount of radiotracer taken up by the tumor, will significantly affect the imaging performance

  2. Inhibition of [11C]mirtazapine binding by alpha2-adrenoceptor antagonists studied by positron emission tomography in living porcine brain

    DEFF Research Database (Denmark)

    Smith, Donald F; Dyve, Suzan; Minuzzi, Luciano

    2006-01-01

    Inhibition of [11C]mirtazapine binding by alpha2-adrenoceptor antagonists studied by positron emission tomography in living porcine brain......Inhibition of [11C]mirtazapine binding by alpha2-adrenoceptor antagonists studied by positron emission tomography in living porcine brain...

  3. Clinical applications of positron emission tomography in breast cancer patients

    International Nuclear Information System (INIS)

    Roemer, W.; Avril, N.; Schwaiger, M.

    1997-01-01

    Increased glucose metabolism by malignant tissue can be visualized with positron emission tomography (PET), using the radiolabeled glucose analogue F-18 fluorodeoxyglucose (FDG). Depending on the criteria of image interpretation FDG-PET allows detection of breast cancer with a sensitivity of 68% to 94 % and a specificity of 84 % to 97 %. However, sensitivity to visualize small tumors (< 1 cm) is limited. Positron emission tomography demonstrates tumor involvement of regional lymph nodes with high accuracy, predominantly in patients with advanced breast cancer. The sensitivity for the detection of axillary lymph node metastases was 79% with a corresponding specificity of 96 %. Lymph node metastases could not be identified in four of six patients with small primary breast cancer (stage pT1), resulting in a sensitivity of only 33% in these patients. By visualizing primary tumors and metastases in one imaging procedure, PET imaging may allow the effective staging of breast cancer patients. Further studies are needed to define the role of scintigraphic techniques for the diagnostic work-up in patients. (author)

  4. Methods and instrumentation for positron emission tomography

    International Nuclear Information System (INIS)

    Mandelkern, M.A.; Phelps, M.E.

    1988-01-01

    This paper reports on positron emission tomography (PET), a technique for the noninvasive measurement of local tissue concentrations of injected radioactive tracers. Tracer kinetics techniques can be applied to this information to quantify physiologic function in human tissue. In the tracer method, a pharmaceutical is labeled by a radioactive atom. When introduced into the subject that molecule follows a physiologic pathway. The space- and time-dependent distribution of the radionuclide is obtained via an imaging technique. If the radiopharmaceutical is sufficiently analogous to a natural substrate or other substance of interest, a quantitative image can be translated into a physiologic measurement

  5. Positron emission tomography in the diagnosis and staging of lung cancer

    DEFF Research Database (Denmark)

    Fischer, B M; Mortensen, J; Højgaard, L

    2001-01-01

    positron emission tomography (PET) and gamma-camera PET in the diagnostic investigation of non-small-cell lung cancer (NSCLC). A systematic literature search was carried out in the MEDLINE and EMBASE databases and the Cochrane Controlled Trials Register. We identified 55 original works on the diagnostic...

  6. A case of skeletal tuberculosis and psoas abscess: disease activity evaluated using 18 F-fluorodeoxyglucose positron emission tomography-computed tomography

    International Nuclear Information System (INIS)

    Kimizuka, Yoshifumi; Hasegawa, Naoki; Ishii, Makoto; Murakami, Koji; Ishioka, Kota; Yagi, Kazuma; Ishii, Ken; Watanabe, Kota; Soejima, Kenzo; Betsuyaku, Tomoko

    2013-01-01

    Psoas abscess complicating tuberculous spondylitis is a rare morbidity in extrapulmonary tuberculosis. There are no established guidelines for evaluating the clinical response of psoas abscess. Although several studies have shown that positron emission tomography-computed tomography with 18 F-fluorodeoxyglucose can play a potential role in diagnosing multifocal tuberculosis and monitoring the clinical response of pulmonary tuberculosis, to our knowledge, this is the first report demonstrating that positron emission tomography-computed tomography is useful for evaluating local inflammation and disease activity of a tuberculous psoas abscess. We report a case of multifocal bone and lymph node tuberculosis with concomitant lumbar psoas abscess in a 77-year-old man, along with a literature review. An initial positron emission tomography-computed tomography scan showed intense 18 F-fluorodeoxyglucose accumulation in the sternum, ribs, vertebrae, and lymph nodes. The patient was successfully treated with antitubercular agents and computed tomography-guided drainage therapy. A follow-up positron emission tomography-computed tomography after abscess drainage and 9 months of antitubercular drug treatment revealed that the majority of lesions improved; however, protracted inflammation surrounding the psoas abscess was still observed. These results indicate that disease activity of psoas abscess can remain, even after successful drainage and antitubercular medication regime of appropriate duration. We have successfully followed up the extent of skeletal tuberculosis complicated with psoas abscess by positron emission tomography-computed tomography. In this patient, positron emission tomography-computed tomography is useful for evaluating the disease activity of tuberculous psoas abscess and for assessing the appropriate duration of antitubercular drug therapy in psoas abscess

  7. Influence of 18F-fluorodeoxyglucose-positron emission tomography on computed tomography-based radiation treatment planning for oesophageal cancer

    International Nuclear Information System (INIS)

    Everitt, C.; Leong, T.

    2006-01-01

    The addition of positron emission tomography (PET) information to CT-based radiotherapy treatment planning has the potential to improve target volume definition through more accurate localization of the primary tumour and involved regional lymph nodes. This case report describes the first patient enrolled to a prospective study evaluating the effects of coregistered positron emission tomography/CT images on radiotherapy treatment planning for oesophageal cancer. The results show that if combined positron emission tomography/CT is used for radiotherapy treatment planning, there may be alterations to the delineation of tumour volumes when compared to CT alone. For this patient, a geographic miss of tumour would have occurred if CT data alone were used for radiotherapy planning Copyright (2006) Blackwell Publishing Asia Pty Ltd

  8. Evaluation of Positron Emission Tomographic Tracers for Imaging of Papillomavirus-Induced Tumors in Rabbits

    Directory of Open Access Journals (Sweden)

    Sonja Probst

    2014-01-01

    Full Text Available In this study, simultaneous positron emission tomography (PET/magnetic resonance (MR imaging was employed to evaluate the feasibility of the PET tracers 2-deoxy-2-18F-fluoro-D-glucose (18F-FDG, 11C-choline, and 18F-fluorothymidine (18F-FLT to detect papillomavirus-induced tumors in an established rabbit model system. The combined PET/MR allowed the analysis of tracer uptake of the tumors using the morphologic information acquired by MR. New Zealand White rabbits were infected with cottontail rabbit papillomavirus genomes and were imaged for up to 10 months with a simultaneous PET/MR system during the course of infection. The uptake characteristics of the PET tracers 11C-choline and 18F-FLT of tumors and reference tissues were examined relative to the clinical standard, 18F-FDG. Tracer biodistribution of various organs was measured by gamma-counting after the last PET scan and compared to the in vivo PET/MR 18F-FDG uptake. Increased tracer uptake was found 2 months postinfection in primary tumors with 18F-FDG and 11C-choline, whereas 18F-FLT failed to detect the tumors at all measured time points. Our data show that the PET tracer 18F-FDG is superior for imaging papillomavirus-induced tumors in rabbits compared to 11C-choline and 18F-FLT. However, 11C-choline imaging, which has previously been applied to detect various tumor entities in patients, appears to be an alternative to 18F-FDG.

  9. Positron emission tomography tracers for imaging angiogenesis

    International Nuclear Information System (INIS)

    Haubner, Roland; Beer, Ambros J.; Wang, Hui; Chen, Xiaoyuan

    2010-01-01

    Position emission tomography imaging of angiogenesis may provide non-invasive insights into the corresponding molecular processes and may be applied for individualized treatment planning of antiangiogenic therapies. At the moment, most strategies are focusing on the development of radiolabelled proteins and antibody formats targeting VEGF and its receptor or the ED-B domain of a fibronectin isoform as well as radiolabelled matrix metalloproteinase inhibitors or α v β 3 integrin antagonists. Great efforts are being made to develop suitable tracers for different target structures. All of the major strategies focusing on the development of radiolabelled compounds for use with positron emission tomography are summarized in this review. However, because the most intensive work is concentrated on the development of radiolabelled RGD peptides for imaging α v β 3 expression, which has successfully made its way from bench to bedside, these developments are especially emphasized. (orig.)

  10. Positron emission tomography of hepatic first-pass metabolism of ammonia in pig

    DEFF Research Database (Denmark)

    Keiding, S; Munk, O L; Roelsgaard, K

    2001-01-01

    Hepatic first-pass metabolism plays a key role in metabolic regulation and drug metabolism. Metabolic processes can be quantified in vivo by positron emission tomography scanning (PET). We wished to develop a PET technique to measure hepatic first-pass metabolism of ammonia. Seven anaesthetised...... pigs were given positron-labelled ammonia, (13)NH(3), into the portal vein and into the vena cava as successive 2-min infusions followed by 22-min dynamic liver scanning. Vena cava infusion data were used to account for recirculation of tracer and metabolites following the portal vein infusion...

  11. Cerebral metabolic data obtained by positron emission tomography in physiological aging. A review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Pellat, J; Hommel, M

    1987-06-18

    Following a summary of the general principles and limitations of metabolic measurements by positron emission tomography and of the different indices used to interpret the data, the authors review the results of published studies on physiological aging. Globally, with strict inclusion criteria absolute metabolic values at rest and under partial sensorial deprivation are little or not modified by age. In contrast, functional interactions between regions, as deduced from metabolic intercorrelations, are perhaps different in elderly people. In any case, positron emission tomography seems to discriminate between normal aging and different patterns of pathological aging. Technical improvements, more refined neuropsychological correlations and the use of dynamic activation paradigms will no doubt provide, in the future, a better definition of normal and pathological aging as positron tomography.

  12. Cerebral metabolic data obtained by positron emission tomography in physiological aging. A review of the literature

    International Nuclear Information System (INIS)

    Pellat, J.; Hommel, M.

    1987-01-01

    Following a summary of the general principles and limitations of metabolic measurements by positron emission tomography and of the different indices used to interpret the data, the authors review the results of published studies on physiological aging. Globally, with strict inclusion criteria absolute metabolic values at rest and under partial sensorial deprivation are little or not modified by age. In contrast, functional interactions between regions, as deduced from metabolic intercorrelations, are perhaps different in elderly people. In any case, positron emission tomography seems to discriminate between normal aging and different patterns of pathological aging. Technical improvements, more refined neuropsychological correlations and the use of dynamic activation paradigms will no doubt provide, in the future, a better definition of normal and pathological aging as positron tomography [fr

  13. Human primary visual cortex topography imaged via positron tomography

    International Nuclear Information System (INIS)

    Schwartz, E.L.; Christman, D.R.; Wolf, A.P.

    1984-01-01

    The visuotopic structure of primary visual cortex was studied in a group of 7 human volunteers using positron emission transaxial tomography (PETT) and 18 F-labeled 2-deoxy-2-fluoro-D-glucose ([ 18 F]DG). A computer animation was constructed with a spatial structure which was matched to estimates of human cortical magnification factor and to striate cortex stimulus preferences. A lateralized cortical 'checker-board' pattern of [ 18 F]DG was stimulated in primary visual cortex by having subjects view this computer animation following i.v. injection of [ 18 F]DG. The spatial structure of the stimulus was designed to produce an easily recognizable 'signature' in a series of 9 serial PETT scans obtained from each of a group of 7 volunteers. The predicted lateralized topographic 'signature' was observed in 6 of 7 subjects. Applications of this method for further PETT studies of human visual cortex are discussed. (Auth.)

  14. Geneva University - The AX-PET experiment : A demonstrator for an axial Positron Emission Tomography

    CERN Multimedia

    Université de Genève

    2012-01-01

    Geneva University École de physique Département de physique nucléaire et corspusculaire 24, quai Ernest-Ansermet 1211 Genève 4 Tél.: (022) 379 62 73 Fax: (022) 379 69 92   Wednesday 14 March 2012 SEMINAIRE DE PHYSIQUE CORPUSCULAIRE 11.15 a.m. - Science II, Auditoire 1S081, 30, quai Ernest-Ansermet, 1211 Genève 4 The AX-PET experiment : A demonstrator for an axial Positron Emission Tomography Dr Chiara CASELLA   ETH Zurich   PET (Positron Emission Tomography) is a tool for in-vivo functional imaging, successfully used since the earliest days of nuclear medicine. It is based on the detection of the two coincident 511 keV photons from the annihilation of a positron, emitted from a radiotracer injected into the body. Tomographic analysis of the coincidence data allows for a 3D reconstructed image of the source distribution. The AX-PET experiment proposes a novel geometrical approach for a PET scanner, in which l...

  15. An automated blood sampling system used in positron emission tomography

    International Nuclear Information System (INIS)

    Eriksson, L.; Bohm, C.; Kesselberg, M.

    1988-01-01

    Fast dynamic function studies with positron emission tomography (PET), has the potential to give accurate information of physiological functions of the brain. This capability can be realised if the positron camera system accurately quantitates the tracer uptake in the brain with sufficiently high efficiency and in sufficiently short time intervals. However, in addition, the tracer concentration in blood, as a function of time, must be accurately determined. This paper describes and evaluates an automated blood sampling system. Two different detector units are compared. The use of the automated blood sampling system is demonstrated in studies of cerebral blood flow, in studies of the blood-brain barrier transfer of amino acids and of the cerebral oxygen consumption. 5 refs.; 7 figs

  16. High resolution and high speed positron emission tomography data acquisition

    International Nuclear Information System (INIS)

    Burgiss, S.G.; Byars, L.G.; Jones, W.F.; Casey, M.E.

    1986-01-01

    High resolution positron emission tomography (PET) requires many detectors. Thus, data collection systems for PET must have high data rates, wide data paths, and large memories to histogram the events. This design uses the VMEbus to cost effectively provide these features. It provides for several modes of operation including real time sorting, list mode data storage, and replay of stored list mode data

  17. Positron emission tomography basic sciences

    CERN Document Server

    Townsend, D W; Valk, P E; Maisey, M N

    2003-01-01

    Essential for students, science and medical graduates who want to understand the basic science of Positron Emission Tomography (PET), this book describes the physics, chemistry, technology and overview of the clinical uses behind the science of PET and the imaging techniques it uses. In recent years, PET has moved from high-end research imaging tool used by the highly specialized to an essential component of clinical evaluation in the clinic, especially in cancer management. Previously being the realm of scientists, this book explains PET instrumentation, radiochemistry, PET data acquisition and image formation, integration of structural and functional images, radiation dosimetry and protection, and applications in dedicated areas such as drug development, oncology, and gene expression imaging. The technologist, the science, engineering or chemistry graduate seeking further detailed information about PET, or the medical advanced trainee wishing to gain insight into the basic science of PET will find this book...

  18. Positron emission tomography: Physics, instrumentation, and image analysis

    International Nuclear Information System (INIS)

    Porenta, G.

    1994-01-01

    Positron emission tomography (PET) is a noninvasive diagnostic technique that permits reconstruction of cross-sectional images of the human body which depict the biodistribution of PET tracer substances. A large variety of physiological PET tracers, mostly based on isotopes of carbon, nitrogen, oxygen, and fluorine is available and allows the in vivo investigation of organ perfusion, metabolic pathways and biomolecular processes in normal and diseased states. PET cameras utilize the physical characteristics of positron decay to derive quantitative measurements of tracer concentrations, a capability that has so far been elusive for conventional SPECT (single photon emission computed tomography) imaging techniques. Due to the short half lives of most PET isotopes, an on-site cyclotron and a radiochemistry unit are necessary to provide an adequate supply of PET tracers. While operating a PET center in the past was a complex procedure restricted to few academic centers with ample resources. PET technology has rapidly advanced in recent years and has entered the commercial nuclear medicine market. To date, the availability of compact cyclotrons with remote computer control, automated synthesis units for PET radiochemistry, high-performance PET cameras, and userfriendly analysis workstations permits installation of a clinical PET center within most nuclear medicine facilities. This review provides simple descriptions of important aspects concerning physics, instrumentation, and image analysis in PET imaging which should be understood by medical personnel involved in the clinical operation of a PET imaging center. (author)

  19. Measurement of regional cerebral metabolic rate for glucose in the human subject with (F-18)-2-deoxy-2-fluoro-d-glucose and emission computed tomography: validation of the method

    International Nuclear Information System (INIS)

    Phelps, M.E.; Huang, S.C.; Hoffman, E.J.; Selin, C.; Kuhl, D.E.

    1977-01-01

    Tracer techniques and models of in vitro quantitative autoradiography and tissue counting for the measure of regional metabolic rates (rMR) are combined with emission computed tomography (ECT). This approach, Physiologic Tomography (PT), provides atraumatic and analytical measurements of rMR. PT is exemplified with the regional measurement of the cerebral metabolic rate for glucose (CMRGlu) in man with ( 18 F)-2-deoxy-2-fluoro-D-glucose (FDG) and positron ECT. Our model incorporates a k 4 * mediated hydrolysis of FDG-6-PO 4 to FDG which then competes with phosphorylation (k 3 *) of FDG back to FDG-6-PO 4 and reverse transport (k 2 *) back to blood. Although small, k 4 * is found to be significant. The ECAT positron tomograph was used to measure the rate constants (k 1 *→k 4 *), lumped constant (LC), stability, and reproducibility of the model in man. Since these parameters have not been measured for FDG in any species, comparisons are made to values for DG in rat and monkey. Compartmental concentrations of FDG and FDG-6-PO 4 were determined and show that cerebral FDG-6-PO 4 steadily accumulates for about 100 mins, plateaus and then slowly decreases due to hydrolysis. Cerebral blood FDG concentration was determined to be a minor contribution to tissue activity after 10 min. Regional CMRGlu measurements are reproducible to +- 5.5% over 5 hrs. PT allows the in vivo study ofregional biochemistry and physiology in normal and pathophysiologic states in man with a unique and fundamental capability

  20. Radiopharmaceuticals for Assessment of Altered Metabolism and Biometal Fluxes in Brain Aging and Alzheimer's Disease with Positron Emission Tomography.

    Science.gov (United States)

    Xie, Fang; Peng, Fangyu

    2017-01-01

    Aging is a risk factor for Alzheimer's disease (AD). There are changes of brain metabolism and biometal fluxes due to brain aging, which may play a role in pathogenesis of AD. Positron emission tomography (PET) is a versatile tool for tracking alteration of metabolism and biometal fluxes due to brain aging and AD. Age-dependent changes in cerebral glucose metabolism can be tracked with PET using 2-deoxy-2-[18F]-fluoro-D-glucose (18F-FDG), a radiolabeled glucose analogue, as a radiotracer. Based on different patterns of altered cerebral glucose metabolism, 18F-FDG PET was clinically used for differential diagnosis of AD and Frontotemporal dementia (FTD). There are continued efforts to develop additional radiopharmaceuticals or radiotracers for assessment of age-dependent changes of various metabolic pathways and biometal fluxes due to brain aging and AD with PET. Elucidation of age-dependent changes of brain metabolism and altered biometal fluxes is not only significant for a better mechanistic understanding of brain aging and the pathophysiology of AD, but also significant for identification of new targets for the prevention, early diagnosis, and treatment of AD.

  1. Persistence of cerebral metabolic abnormalities in chronic schizophrenia as determined by positron emission tomography

    International Nuclear Information System (INIS)

    Wolkin, A.; Jaeger, J.; Brodie, J.D.; Wolf, A.P.; Fowler, J.; Rotrosen, J.; Gomez-Mont, F.; Cancro, R.

    1985-01-01

    Local cerebral metabolic rates were determined by positron emission tomography and the deoxyglucose method in a group of 10 chronic schizophrenic subjects before and after somatic treatment and in eight normal subjects. Before treatment, schizophrenic subjects had markedly lower absolute metabolic activity than did normal controls in both frontal and temporal regions and a trend toward relative hyperactivity in the basal ganglia area. After treatment, their metabolic rates approached those seen in normal subjects in nearly all regions except frontal. Persistence of diminished frontal metabolism was manifested as significant relative hypofrontality. These findings suggest specific loci of aberrant cerebral functioning in chronic schizophrenia and the utility of positron emission tomography in characterizing these abnormalities

  2. Tissue distributions of radiopharmaceuticals labeled with positron emitters and problems in relating them to human studies

    International Nuclear Information System (INIS)

    Christman, D.R.

    1980-01-01

    This paper discusses a few specific examples of organ distributions involving positron-emitting nuclides intended to illustrate some specific points in this area. In particular, work with 2-fluoro-2-deoxyglucose will be discussed in some detail, and its distribution in the body compared with the closely related (chemically but not biologically) 3-fluoro-3-deoxyglucose and 1- 11 C-2-deoxyglucose. Other compounds labeled with these two nuclides, and with 13 N and 15 O will also be discussed

  3. Positron emission tomography in the follow-up of cutaneous malignant melanoma patients

    DEFF Research Database (Denmark)

    Danielsen, Maria; Højgaard, Liselotte; Kjær, Andreas

    2014-01-01

    node involvement and distant metastases, accentuating the importance of close surveillance to identify disease progression at an early stage, and thereby detect recurrences amenable to treatment. Positron emission tomography (PET) has already been proven useful in the staging of CMM, but the utility...

  4. Application of positron emission tomography in industrial research

    International Nuclear Information System (INIS)

    Jonkers, G.; van den Bergen, E.A.; Vonkeman, K.A.

    1990-01-01

    Positron Emission computed Tomography (PET) is a relatively new imaging technique, exploiting the 511 keV annihilation radiation characteristic of positron emitters. Although exclusively used till now in the field of nuclear medicine, the application of PET for the non-invasive, in-situ visualisation of processes of industrial interest is challenging, because PET can in principle be used to obtain quantitative, 2D/3D images of the flow and distribution of fluids inside process units, whose steel walls may be up to several centimeters thick. With the aid of a NeuroECAT positron tomographer the PET technique has been utilised to image important (model) processes in the petrochemical industry, using physical labelling of the phase to be imaged. First, the displacement of a brine/surfactant phase, labelled with 66 Ga-EDTA, in a piece of reservoir rock was imaged. Secondly, the dehydration of water-in-oil emulsions was monitored dynamically by labelling the water phase with 68 Ga-EDTA. The second study in particular demonstrates that in the presence of noisy data the image reconstruction method utilised strongly influences the results obtained. With the advent of PET in nuclear medicine the availability of short-lived positron emitting nuclides like 11 C (t1/2 = 20 min), 13 N (t1/2 = 10 min) and 15 0 (t1/2 = 2 min) has increased considerably, allowing the investigation of industrially important reactions by chemical labelling. Utilising the NeuroECAT in a special mode, the catalytic oxidation of carbon monoxide could be imaged in a model tubular reactor by using 11 C-labelled CO, providing information about the kinetics of the individual reaction steps and interactions and about the degree of occupation of catalytically active sites. (author)

  5. Contribution of positron emission tomography in neurology

    International Nuclear Information System (INIS)

    Salmon, E.; Franck, G.

    1992-01-01

    Positron Emission Tomography (PET) is a scanner technique using tracers labelled with shortlived radioisotopes which allows to study and quantify human metabolic processes or drug pharmacology in vivo. The technique is first applied in physiological studies. Sleep, normal brain metabolism or cerebral activations have been studied. The pharmacological approach concerns both drug distribution in the human brain and blood flow or metabolic variations under treatment. Main neurological applications in pathology are cerebrovascular disorders, diseases leading to dementia, epilepsy, movement disorders, and brain tumors. In each field of application, PET gives unique and frequently early informations. It nicely combines both dynamic informations and measurement precision. (author)

  6. Use of positron emission tomography in colorectal cancer

    International Nuclear Information System (INIS)

    Gonzalez E, Patricio; Jofre E, Josefina; Massardo V, Teresa; Humeres, Pamela; Canessa G, Jose; Sierralta C, Paulina

    2002-01-01

    The value of PET (Positron Emission Tomography) in colorectal cancer is presented. PET is a novel technique that uses F-18-FDG (fluorodeoxiglucose) to assess glucose metabolism by whole body imaging. It has been demonstrated that malignant cells have both increase of glucose uptake and utilization. In colorectal cancer, PET is indicated for staging, assess recurrence, liver metastasis and treatment follow-up. PET is more sensitive and specific than CT (Computed Tomography) and is cost effective. In 30% of cases PET may change patient management, avoiding unnecessary procedures (au)

  7. Design of a volume-imaging positron emission tomograph

    International Nuclear Information System (INIS)

    Harrop, R.; Rogers, J.G.; Coombes, G.H.; Wilkinson, N.A.; Pate, B.D.; Morrison, K.S.; Stazyk, M.; Dykstra, C.J.; Barney, J.S.; Atkins, M.S.; Doherty, P.W.; Saylor, D.P.

    1988-11-01

    Progress is reported in several areas of design of a positron volume imaging tomograph. As a means of increasing the volume imaged and the detector packing fraction, a lens system of detector light coupling is considered. A prototype layered scintillator detector demonstrates improved spatial resolution due to a unique Compton rejection capability. The conceptual design of a new mechanism for measuring scattered radiation during emission scans has been tested by Monte Carlo simulation. The problem of how to use effectively the resulting sampled scattered radiation projections is presented and discussed

  8. Intrinsic spatial resolution limitations due to differences between positron emission position and annihilation detection localization

    International Nuclear Information System (INIS)

    Perez, Pedro; Malano, Francisco; Valente, Mauro

    2012-01-01

    Since its successful implementation for clinical diagnostic, positron emission tomography (PET) represents the most promising medical imaging technique. The recent major growth of PET imaging is mainly due to its ability to trace the biologic pathways of different compounds in the patient's body, assuming the patient can be labeled with some PET isotope. Regardless of the type of isotope, the PET imaging method is based on the detection of two 511-keV gamma photons being emitted in opposite directions, with almost 180 deg between them, as a consequence of electron-positron annihilation. Therefore, this imaging method is intrinsically limited by random uncertainties in spatial resolutions, related with differences between the actual position of positron emission and the location of the detected annihilation. This study presents an approach with the Monte Carlo method to analyze the influence of this effect on different isotopes of potential implementation in PET. (author)

  9. A case of skeletal tuberculosis and psoas abscess: disease activity evaluated using (18) F-fluorodeoxyglucose positron emission tomography-computed tomography.

    Science.gov (United States)

    Kimizuka, Yoshifumi; Ishii, Makoto; Murakami, Koji; Ishioka, Kota; Yagi, Kazuma; Ishii, Ken; Watanabe, Kota; Soejima, Kenzo; Betsuyaku, Tomoko; Hasegawa, Naoki

    2013-11-14

    Psoas abscess complicating tuberculous spondylitis is a rare morbidity in extrapulmonary tuberculosis. There are no established guidelines for evaluating the clinical response of psoas abscess. Although several studies have shown that positron emission tomography-computed tomography with 18 F-fluorodeoxyglucose can play a potential role in diagnosing multifocal tuberculosis and monitoring the clinical response of pulmonary tuberculosis, to our knowledge, this is the first report demonstrating that positron emission tomography-computed tomography is useful for evaluating local inflammation and disease activity of a tuberculous psoas abscess. We report a case of multifocal bone and lymph node tuberculosis with concomitant lumbar psoas abscess in a 77-year-old man, along with a literature review. An initial positron emission tomography-computed tomography scan showed intense 18 F-fluorodeoxyglucose accumulation in the sternum, ribs, vertebrae, and lymph nodes. The patient was successfully treated with antitubercular agents and computed tomography-guided drainage therapy. A follow-up positron emission tomography-computed tomography after abscess drainage and 9 months of antitubercular drug treatment revealed that the majority of lesions improved; however, protracted inflammation surrounding the psoas abscess was still observed. These results indicate that disease activity of psoas abscess can remain, even after successful drainage and antitubercular medication regime of appropriate duration. We have successfully followed up the extent of skeletal tuberculosis complicated with psoas abscess by positron emission tomography-computed tomography. In this patient, positron emission tomography-computed tomography is useful for evaluating the disease activity of tuberculous psoas abscess and for assessing the appropriate duration of antitubercular drug therapy in psoas abscess.

  10. The value of positron emission tomography/computed tomography for evaluating metastatic disease in patients with pancreatic cancer.

    Science.gov (United States)

    Kim, Mi-Jin; Lee, Kwang Hyuck; Lee, Kyu Taek; Lee, Jong Kyun; Ku, Bon-Ho; Oh, Cho-Rong; Heo, Jin Seok; Choi, Seong-Ho; Choi, Dong Wook

    2012-08-01

    Routine application of positron emission tomography/computed tomography (PET/CT) for pancreatic cancer staging remains a controversial approach. The purpose of this study was to reassess the clinical impact of PET/CT for the detection of distant metastasis of pancreatic cancer. From January 2006 to June 2009, 125 patients with histologically proven pancreatic cancer that had undergone PET/CT at our hospital were retrospectively reviewed. To evaluate the clinical efficacy of PET/CT on the management plan, the post-PET/CT management plans were compared with the pre-PET/CT management plans. After the conventional staging workup, we determined that 76 patients (60.8%) had resectable lesions, whereas 48 patients had unresectable lesions. One patient underwent explorative laparotomy due to equivocal resectability. Positron emission tomography/computed tomography diagnosed distant metastasis in only 2 (2.6%) of the 76 patients with resectable lesions, and these patients did not undergo unnecessary surgical treatment. Complete resection was not performed in 8 of the 74 operative patients because they had distant metastasis detected during the operative procedure. Positron emission tomography/computed tomography diagnosed distant metastasis in 32 of the 44 patients with metastatic lesions that were histologically shown to have sensitivity of 72.7%. Positron emission tomography/computed tomography has a limited role in the evaluation of metastatic disease from pancreatic cancer.

  11. Application of positron emission tomography in the lung

    International Nuclear Information System (INIS)

    Valind, S.O.; Wollmer, P.E.; Rhodes, C.G.

    1985-01-01

    The early application of positron emission tomography in the lung was mainly concerned with the investigation of the regional volume of the vascular and extravascular compartments, using measurements of fractional blood volume and lung density. However, in addition to its passive role in the exchange of oxygen and carbon dioxide, the lung exerts a number of active, metabolic functions such as the inactivation of circulating vasoactive compounds and the synthesis and release of biologically active substances. Furthermore, many of the pulmonary disorders originate at a cellular or metabolic level, or have metabolic consequences. Many of the substrates of biochemical reactions and the biologically active compounds, or their analogs, can be labeled with positron-emitting radioisotopes without disturbing their biological or biochemical characteristics. In combination with the development of the appropriate physiological and biochemical models, the quantitative measurements possible with PET provide a unique opportunity of regionally studying the metabolic processes of the lung of man in vivo. Hence, a range of different expressions of metabolism and of lung function can be evaluated and their interdependence can be studied regionally

  12. Practical no-gold-standard evaluation framework for quantitative imaging methods: application to lesion segmentation in positron emission tomography.

    Science.gov (United States)

    Jha, Abhinav K; Mena, Esther; Caffo, Brian; Ashrafinia, Saeed; Rahmim, Arman; Frey, Eric; Subramaniam, Rathan M

    2017-01-01

    Recently, a class of no-gold-standard (NGS) techniques have been proposed to evaluate quantitative imaging methods using patient data. These techniques provide figures of merit (FoMs) quantifying the precision of the estimated quantitative value without requiring repeated measurements and without requiring a gold standard. However, applying these techniques to patient data presents several practical difficulties including assessing the underlying assumptions, accounting for patient-sampling-related uncertainty, and assessing the reliability of the estimated FoMs. To address these issues, we propose statistical tests that provide confidence in the underlying assumptions and in the reliability of the estimated FoMs. Furthermore, the NGS technique is integrated within a bootstrap-based methodology to account for patient-sampling-related uncertainty. The developed NGS framework was applied to evaluate four methods for segmenting lesions from F-Fluoro-2-deoxyglucose positron emission tomography images of patients with head-and-neck cancer on the task of precisely measuring the metabolic tumor volume. The NGS technique consistently predicted the same segmentation method as the most precise method. The proposed framework provided confidence in these results, even when gold-standard data were not available. The bootstrap-based methodology indicated improved performance of the NGS technique with larger numbers of patient studies, as was expected, and yielded consistent results as long as data from more than 80 lesions were available for the analysis.

  13. Lhermitte-Duclos disease presenting with positron emission tomography-magnetic resonance fusion imaging: a case report

    Directory of Open Access Journals (Sweden)

    Calabria Ferdinando

    2012-03-01

    Full Text Available Abstract Introduction Lhermitte-Duclos disease or dysplastic gangliocytoma of the cerebellum is an extremely rare tumor. It is a slowly enlarging mass within the cerebellar cortex. The majority of cases are diagnosed in the third or fourth decade of life. Case presentation We report the case of a 37-year-old Caucasian woman who underwent positron emission tomography-computed tomography with fluorine-18-fluorodeoxyglucose for evaluation of a solitary lung node. No pathological uptake was detected in the solitary lung node but the positron emission tomography-computed tomography of her brain showed intense tracer uptake, suggestive of a malignant neoplasm, in a mass in her left cerebellar lobe. Our patient had experienced two years of occipital headache and movement disorder. Subsequently, magnetic resonance imaging was performed with contrast agent administration, showing a large subtentorial mass in her left cerebellar hemisphere, with compression and dislocation of the fourth ventricle. Metabolic data provided by positron emission tomography and morphological magnetic resonance imaging views were fused in post-processing, allowing a diagnosis of dysplastic gangliocytoma with increased glucose metabolism. Total resection of the tumor was performed and histological examination confirmed the diagnosis of Lhermitte-Duclos disease. Conclusions Our case indicates that increased uptake of fluorine-18-fluorodeoxyglucose may be misinterpreted as a neoplastic process in the evaluation of patients with Lhermitte-Duclos disease, but supports the usefulness of integrated positron emission tomography-magnetic resonance imaging in the exact pathophysiologic explanation of this disease and in making the correct diagnosis. However, an accurate physical examination and exact knowledge of clinical data is of the utmost importance.

  14. Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography in Disseminated Cryptococcosis.

    Science.gov (United States)

    Tripathy, Sarthak; Parida, Girish Kumar; Roy, Shambo Guha; Singhal, Abhinav; Mallick, Saumya Ranjan; Tripathi, Madhavi; Shamim, Shamim Ahmed

    2017-01-01

    Disseminated cryptococcosis without pulmonary involvement is a very rare phenomenon. Patterns of organ involvement in cryptococcosis resemble various other infective conditions as well as malignant conditions on fluorodeoxyglucose positron emission tomography-computed tomography. We present a case of a 43-year-old male patient who had disseminated cryptococcosis. The rarity of the case being noninvolvement of lungs and meninges and resembling more like lymphoma due to the diffuse involvement of the lymph nodes on both sides of the diaphragm.

  15. 18F-FDG PET/CT-based early treatment response evaluation of nanoparticle-assisted photothermal cancer therapy.

    Science.gov (United States)

    Norregaard, Kamilla; Jørgensen, Jesper T; Simón, Marina; Melander, Fredrik; Kristensen, Lotte K; Bendix, Pól M; Andresen, Thomas L; Oddershede, Lene B; Kjaer, Andreas

    2017-01-01

    Within the field of nanoparticle-assisted photothermal cancer therapy, focus has mostly been on developing novel heat-generating nanoparticles with the right optical and dimensional properties. Comparison and evaluation of their performance in tumor-bearing animals are commonly assessed by changes in tumor volume; however, this is usually a late-occurring event. This study implements 2-deoxy-2-[F-18]fluoro-D-glucose positron emission tomography imaging to perform early evaluation of the treatment outcome of photothermal therapy. Silica-gold nanoshells (NS) are administered intravenously to nude mice bearing human neuroendocrine tumor xenografts and the tumors are irradiated by a near-infrared laser. The animals are positron emission tomography scanned with 2-deoxy-2-[F-18]fluoro-D-glucose one day before and one day after treatment. Using this setup, a significant decrease in tumor uptake of 2-deoxy-2-[F-18]fluoro-D-glucose is found already one day after therapy in the group receiving NS and laser treatment compared to control animals. At this time point no change in tumor volume can be detected. Moreover, the change in tumor uptake, is used to stratify the animals into responders and non-responders, where the responding group matched improved survival. Overall, these findings support the use of 2-deoxy-2-[F-18]fluoro-D-glucose positron emission tomography imaging for preclinical and clinical evaluation and optimization of photothermal therapy.

  16. Misonidazole and unconventional radiation in advanced squamous cell carcinoma of the esophagus: a phase II study of the Radiation Therapy Oncology Group

    International Nuclear Information System (INIS)

    Ydrach, A.A.; Marcial, V.A.; Parsons, J.; Concannon, J.; Asbell, S.O.; George, F.

    1982-01-01

    This is a report on Radiation Therapy Oncology Group (RTOG) Protocol78-32, a Phase I/II prospective study aimed at determining tolerance, tumor response, and survival of squamous cell carcinoma of the esophagus treated with unorthodox fractionation radiotherapy combined with misonidazole. Misonidazole was administered by mouth 4 to 6 hr prior to radiation, at a dose of 1.0 to 1.25 Gm/.m 2 ; blood levels were measured at about 4 hr after intake of the drug and reported in micrograms/ml. Radiotherapy was administered at 4 to 6 hr post-misonidazole dose and given with 400 rad fractions, alternating 2 or 3 times/week, up to 4,800 rad. A total of 43 patients were entered; 26 are evaluated for survival at 1 year post accession. Thirty patients (88%) received the planned radiation course. Twenty-eight patients (78%) received the planned misonidazole dosage. Tumor response, evaluated in 18 patients, showed a complete regression (C.R.) in only 2 patients (11%); and partial response (P.R.) in 6 patients (33%). Eight patients (44%) showed no tumor response to planned therapy. Toxicity was acceptable and in 38 evaluated patients only 4 reported (11%) nausea and vomiting, 7 reported mild paresthesias (18%). The median survival was only five months. In 26 patients evaluated for 1 year survival determination, only 1 survived (3.8%) this period. In view of the poor tumor response and low survival observed, we do not recommend that this particular fractionation regimen with misonidazole be used in a Phase III randomized trial in squamous cell carcinoma of the esophagus

  17. Positron emission tomography in drug development

    International Nuclear Information System (INIS)

    Rubin, R. H.; Fischman, A. J.

    1997-01-01

    There are four kinds of measurements that can be carried out with positron emission tomography (PET) that can contribute significantly to the process of drug development: pharmacodynamic measurement of tissue metabolism influenced by a given drug; precise measurements of tissue blood flow; tissue pharmacokinetics of a given drug following administration of a particular dose; and the temporal course of ligand-receptor interaction. One or more of these measurements can greatly improve the decision making involved in determining the appropriate dose of a drug, the clinical situations in which a drug might be useful, and the linkage of pharmacokinetics with pharmacodynamics, which is at the heart of effective drug development. The greater the potential of a particular compound as a therapeutic agent, the greater the potential for PET to contribute to the drug development process

  18. Positron emission tomography in oncology

    International Nuclear Information System (INIS)

    Lecomte, R.; Bentourkia, M.; Benard, F.

    2002-01-01

    Positron Emission Tomography is a sophisticated molecular imaging technique, using a special scanner, that displays the functional status of tissues in the body at the cellular level (their metabolism). It is a diagnostic scan that provides the physician with information not available with traditional anatomic studies such as CT or MRI. PET can detect changes in cell function (disease) long before they are evident as physical (anatomic) changes seen on CT or MRI. In this way PET can add important information about many diseases allowing the physician to make a diagnosis often much earlier than with anatomic imaging techniques such as CT or MRI alone. In addition, in cases where an abnormality is noted on CT or MRI, PET can help differentiate benign changes from changes due to disease. PET scanning also typically images the entire body, unlike CT/MRI which is usually broken up into specific limited body section scans. All cells use glucose as an energy source but cancer cells use much more since they are growing much faster and out of control. This is the basis of imaging with F-18 FDG glucose, the radiotracer agent use in a PET oncology study. The abnormal, accelerated glucose used by cancer cells is detected by the PET scanner that processes the emissions from the F-18 FDG glucose by abnormally high levels of metabolism (tumor)

  19. Brain kinetics of L-[β-11C]DOPA in humans studied by positron emission tomography

    International Nuclear Information System (INIS)

    Hartvig, P.; Agren, H.; Reibring, L.; Tedroff, J.; Bjurling, P.; Kihlberg, T.; Langstroem, B.

    1991-01-01

    The in vivo dopamine precursor L-3,4-dihydroxyphenylalanine (L-DOPA) labelled with 11 C in the β position has been used for positron emission tomography studies of L-DOPA utilization in the brain. The brain uptake and kinetics of L-[ 11 C]DOPA-derived radioactivity were studied in healthy male volunteers, and the specific utilization, i.e. decarboxylation rate of L-[ 11 C]DOPA in different brain areas, was quantified using a brain region devoid of specific L-[ 11 C]DOPA utilization as reference. Total uptake of L-[ 11 C]DOPA-derived radioactivity measured in the brain varied two- to three-fold between subjects, with highest radioactivity in the striatal region. Specific utilization of L-[ 11 C]DOPA radioactivity in the striatal region and in the prefrontal cortex varied twofold between subjects. No specific utilization was observed in other regions of the brain. The uptake of radioactivity in the brain increased dose-dependently with the simultaneous administration of unlabelled L-DOPA up to 10 mg. On the other hand, a decrease in brain radioactivity uptake was measured after pretreatment with 1 mg/kg oral L-DOPA, indicating competition for transport across the blood-brain barrier. Benserazide 0.5mg/kg orally increased somewhat the radioactivity uptake to the brain. None of these pharmacological perturbations demonstrated any clearcut effect on specific utilization of L-[ 11 C]DOPA. Thus, 11 C-labelled L-DOPA is introduced as an alternative to the well-established L-6-[ 18 F]fluoro-DOPA methodology in clinical studies on brain L-DOPA uptake and dopamine synthesis. (authors)

  20. Cobalt-55 positron emission tomography in traumatic brain injury : A pilot study

    NARCIS (Netherlands)

    Jansen, HML; vanderNaalt, J; vanZomeren, AH; Paans, AMJ; VeenmavanderDuin, L; Hew, JM; Pruim, J; Minderhoud, JM; Korf, J

    Traumatic brain injury is usually assessed with the Glasgow coma scale (GCS), CT, or MRI. After such injury, the injured brain tissue is characterised by calcium mediated neuronal damage and inflammation. Positron emission tomography with the isotope cobalt-55 (Go-PET) as a calcium tracer enables

  1. Investigation of positron moderator materials for electron-linac-based slow positron beamlines

    International Nuclear Information System (INIS)

    Suzuki, Ryoichi; Ohdaira, Toshiyuki; Uedono, Akira

    1998-01-01

    Positron re-emission properties were studied on moderator materials in order to improve the positron moderation system of electron-linac-based intense slow positron beamlines. The re-emitted positron fraction was measured on tungsten, SiC, GaN, SrTiO 3 , and hydrogen-terminated Si with a variable-energy pulsed positron beam. The results suggested that tungsten is the best material for the primary moderator of the positron beamlines while epitaxially grown n-type 6H-SiC is the best material for the secondary moderator. Defect characterization by monoenergetic positron beams and surface characterization by Auger electron spectroscopy were carried out to clarify the mechanism of tungsten moderator degradation induced by high-energy electron irradiation. The characterization experiments revealed that the degradation is due to both radiation-induced vacancy clusters and surface carbon impurities. For the restoration of degraded tungsten moderators, oxygen treatment at ∼900degC is effective. Furthermore, it was found that oxygen at the tungsten surface inhibits positronium formation; as a result, it can increase the positron re-emission fraction. (author)

  2. Positron emission tomography - a new technique for observing fluid behaviour in engineering systems

    International Nuclear Information System (INIS)

    Stewart, P.A.E.; Rogers, J.D.; Skelton, R.T.

    1988-01-01

    Positron emission tomography promises to become a powerful new technique for flow tracing and measurement within metal structures in general and operating engines in particular. The principles involved are outlined, and a mobile positron camera system being developed jointly by Rolls-Royce, Castrol, the University of Birmingham and the Rutherford-Appleton Laboratory of the SERC is described. Finally, illustrative examples of the camera's capability are presented drawn from its use to study lubricating fluid flow in the bearings of a Viper gas turbine engine on test up to 100% full power. (author)

  3. Effects of oxygen and misonidazole on cell transformation and cell killing in C3H 10T1/2 cells by X rays in vitro

    International Nuclear Information System (INIS)

    Borsa, J.; Sargent, M.D.; Einspenner, M.; Azzam, E.I.; Raaphorst, G.P.

    1984-01-01

    The effects of oxygen (air) and misonidazole on the transformation and killing of 10T1/2 cells by X rays were examined. The oxygen effect for the cell transformation end point was very similar to that for cell killing. Misonidazole enhanced both cell killing and cell transformation to a similar extent. The enhancement of both end points by misonidazole occurred only in the absence of oxygen during irradiation and was of lesser magnitude than that observed for oxygen. These results demonstrate that the radiation chemical processes leading to cell killing and cell transformation, respectively, are affected similarly by these two enhancers of radiation action. 22 references, 3 figures, 2 tables

  4. Fluorodeoxyglucose Positron Emission Tomography–Computed Tomography in Disseminated Cryptococcosis

    Science.gov (United States)

    Tripathy, Sarthak; Parida, Girish Kumar; Roy, Shambo Guha; Singhal, Abhinav; Mallick, Saumya Ranjan; Tripathi, Madhavi; Shamim, Shamim Ahmed

    2017-01-01

    Disseminated cryptococcosis without pulmonary involvement is a very rare phenomenon. Patterns of organ involvement in cryptococcosis resemble various other infective conditions as well as malignant conditions on fluorodeoxyglucose positron emission tomography–computed tomography. We present a case of a 43-year-old male patient who had disseminated cryptococcosis. The rarity of the case being noninvolvement of lungs and meninges and resembling more like lymphoma due to the diffuse involvement of the lymph nodes on both sides of the diaphragm. PMID:29142368

  5. Imaging prostate cancer: an update on positron emission tomography and magnetic resonance imaging

    DEFF Research Database (Denmark)

    Bouchelouche, Kirsten; Turkbey, Baris; Choyke, Peter

    2010-01-01

    , and molecular imaging information. Developments in imaging technologies, specifically magnetic resonance imaging (MRI) and positron emission tomography (PET)/computed tomography (CT), have improved the detection rate of prostate cancer. MRI has improved lesion detection and local staging. Furthermore, MRI...

  6. High-resolution PET [Positron Emission Tomography] for Medical Science Studies

    Science.gov (United States)

    Budinger, T. F.; Derenzo, S. E.; Huesman, R. H.; Jagust, W. J.; Valk, P. E.

    1989-09-01

    One of the unexpected fruits of basic physics research and the computer revolution is the noninvasive imaging power available to today's physician. Technologies that were strictly the province of research scientists only a decade or two ago now serve as the foundations for such standard diagnostic tools as x-ray computer tomography (CT), magnetic resonance imaging (MRI), magnetic resonance spectroscopy (MRS), ultrasound, single photon emission computed tomography (SPECT), and positron emission tomography (PET). Furthermore, prompted by the needs of both the practicing physician and the clinical researcher, efforts to improve these technologies continue. This booklet endeavors to describe the advantages of achieving high resolution in PET imaging.

  7. Comparison of the incidence of oncogenic transformation produced by x-rays, misonidazole, and chemotherapy agents

    International Nuclear Information System (INIS)

    Hall, E.J.; Miller, R.C.; Osmak, R.; Zimmerman, M.

    1982-01-01

    An established line of mouse fibroblasts (10T1/2 cells) cultured in vitro was used to compare the incidence of oncogenic transformation produced by x rays, the hypoxic cell radiosensitizer misonidazole, and a range of commonly used chemotherapy agents. A 3-day exposure to misonidazole at a concentration obtainable during treatment produced an incidence of transformation similar to that of about 50 rad. When chemotherapy agents were tested at concentrations comparable to those used clinically and matched to produce similar cell killing, the incidence of transformation varied widely: some agents, such as vincristine, did not produce transformation at a level detectable above background, while others, such as cis-plantinum, appear to be potent carcinogens and produce transformation at a rate orders of magnitude higher than that achieved with x rays

  8. Serial non-invasive assessment of antibody induced nephritis in mice using positron emission tomography.

    Directory of Open Access Journals (Sweden)

    Guiyang Hao

    Full Text Available Mouse models of experimental anti-glomerular basement membrane (anti-GBM nephritis provide an analytical tool for studying spontaneous lupus nephritis. The potential of Positron Emission Tomography (PET was evaluated using 2-deoxy-2-[(18F]fluoro-d-glucose (FDG as a probe to monitor the progression of anti-GBM induced nephritis in a mouse model. The imaging results were compared to conventional measures of renal function and pathological changes. Serum and urinary vascular cell adhesion molecule-1 (VCAM-1 levels were used as measures of endothelial cell activation and inflammation. Following a challenge with anti-glomerular antibodies, mice exhibited peak changes in serum creatinine, proteinuria, and glomerulonephritis score at 14 days post-challenge (p.c.. In contrast, VCAM levels peaked at day 7 p.c. On dynamic PET images (0-60 min of day 7, kidneys of the anti-GBM nephritis mice demonstrated a unique pattern of FDG uptake. Compared to the time activity curve (TAC prior to challenge, a rightward shift was observed after the challenge. By day 10 p.c., kidney FDG uptake was lower than baseline and remained so until the study ended at 21 days p.c. During this time frame measures of renal dysfunction remained high but VCAM-1 levels declined. These changes were accompanied by an increase in kidney volume as measured by Computed Tomography (CT and intra-abdominal fluid collection. Our results suggest that FDG-PET-CT can be used as a non-invasive imaging tool to longitudinally monitor the progression of renal disease activity in antibody mediated nephritis and the magnitude of renal FDG retention correlates better with early markers of renal inflammation than renal dysfunction.

  9. single photon emission tomography and positron emission tomography - Part 1 (October 2012), Part 2 (October 2010)

    International Nuclear Information System (INIS)

    Buvat, Irene

    2010-10-01

    The objective of this lecture is to present the single photon emission computed tomography (SPECT) and the positron emission tomography (PET) imaging techniques. Part 1 Content: 1 - Introduction: anatomic, functional and molecular imaging; 2 - Radiotracers: chemical and physical constraints, gamma photon emitters, positon emitters, radioisotopes production, emitters type and imaging techniques; 3 - Gamma cameras; 4 - Quantification in emission tomography: attenuation, scattering, un-stationary spatial resolution; 5 - Synthesis and conclusion. Part 2 content: 1 - Positon emitters; 2 - Positons detection: Coincidence detection (electronic collimation, PET detectors with gamma cameras, dedicated PET detectors, spectrometry); PET detectors type; time-of-flight PET; 2D PET; 3D PET; 3 - Quantification in emission tomography: detected events, attenuation, scattering, fortuitous coincidences, standardisation; 4 - Common SPECT and PET problems: partial volume effect, movement, tomographic reconstruction, calibration, dead time; 5 - Synthesis and conclusion

  10. Characterization of hepatic tumors using [11C]metomidate through positron emission tomography

    DEFF Research Database (Denmark)

    Roivainen, Anne; Naum, Alexandru; Nuutinen, Heikki

    2013-01-01

    ABSTRACT: BACKGROUND: Using positron emission tomography (PET), we compared two tracers, [11C]metomidate ([11C]MTO) and [11C]acetate ([11C]ACE), for the characterization of hepatic tumors. METHODS: Thirty-three patients underwent PET with [11C]MTO and [11C]ACE and magnetic resonance imaging (MRI...

  11. The role of positron emission tomography in mediastinal staging of patients with non-small cell lung cancer.

    Science.gov (United States)

    d'Amico, Andrea; Turska-d'Amico, Maria; Jarzab, Barbara; Zielinski, Marcin

    2015-01-01

    To examine the diagnostic accuracy of positron emission tomography/computed tomography in evaluating the mediastinum of patients with non-small cell lung cancer compared to histopathology results. The prospective study was conducted at the Department of Thoracic Surgery of the Pulmonary Hospital in Zakopane, Poland, from September 2008 to August 2012 and comprised patients with radiologically-suspected lung cancer. All patients underwent histological verification by either mediastinoscopy alone or thoracotomy with mediastinal lymphanedectomy. Computed tomography and positron emission tomography/computed tomography data sets were compared with the results of the histopathology examinations. There were 80 patients in the study. In the diagnosis of mediastinal lymph nodes, computed tomography was able to detect 9(11.25%) true-positive, 17(21.25%) false-positive, 40(50%) true-negative and 14(17.5%) false-negative cases. The sensitivity, specificity and accuracy of the method were found to be 39%, 70% and 61% respectively, while the positive and negative predictive values were 35% and 74%. Positron emission tomography/computed tomography yielded 15(18.75%) true-positive, 12(15%) false-positive, 46(57.5%) true-negative and 7(8.75%) false-negative cases. Sensitivity was 68% while specificity was 79%. The accuracy was 96%, and the positive and negative predictive values were 55% and 87% respectively. Positron emission tomography/computed tomography had higher diagnostic accuracy than computed tomography in assessing mediastinal lymph nodes of patients with non-small cell lung cancer. However, a positive test requires histopathology confirmation.

  12. Positron emission tomography. Present status and Romanian perspectives

    International Nuclear Information System (INIS)

    Constantinescu, B.; Lungu, V.

    1995-01-01

    Basic principles of the positron emission tomography (PET) are summarised. The main PET methods using short-lived radioisotopes (i.e. 11 C, 13 N, 15 O, 18 F) are briefly reviewed. Three types of particle accelerators for radioisotopes production and medical uses (including radiotherapy), corresponding to the proton energy (E p p p < 200 MeV) are presented. PET imaging equipment and procedures are discussed. Main radiopharmaceuticals based on beta decay for PET studies and their role in medicine is also described. Finally, perspectives for a PET program in Romania (Cyclotron + Radiochemistry + Tomograph ) are discussed. (author)

  13. Synthesis of stereo (R and S) and geometric (E and Z) [F-18]fluoro-β-fluoromethylene-M-tyrosine derivatives: specific PET probes for central dopamine systems

    International Nuclear Information System (INIS)

    Lacan, G.; Barrio, J.R.; Satyamurthy, N.; Yu, D.C.; Huang, S.C.; Phelps, M.E.

    1994-01-01

    Racemic β-fluoromethylene-m-tyrosine (FMMl) was developed as an aromatic amino acid decarboxylase (AAAD)- activated monoamine oxidase (MAO) suicide inhibitor. Direct [F-18] fluorination of pure enantiomers, R and S-(E)-β- fluoromethylene-m-tyrosine (E-FMMT) and the racemic geometric isomer R,S(Z)-β-fluoromethylene-m-tyrosine (Z-FMMT) with [F- 18] acetylhypofluorite, afforded 6- and 2[F-18] fluoro positional isomers as the major products. Regioselective radiofluorodestannylation of the respective 4-trimethylstannyl R,S- (E) - FMMT with [F-18]F 2 yielded the 4[F-18] fluoro derivative, thus allowing for the systematic evaluation of the regio- and stereo radiofluorinated AAAD probes. Macacca nemestrina monkeys were injected iv with purified radiofluorinated FMMT analogs and the distribution of activity in the central dopaminergic system was studied with positron emission tomography (PET). Radiofluorinated stereo and geometric FMMT derivatives showed significant differences in their in vivo striatal localization, with radioprobe localization decreasing in the order: 6F-S-(E)-FMMT >> 2F-S-(E)- FMMT >> 4F-R,S-(E)-FMMT. Neither radiofluorinated analogs of R-(E)- FMMT and R,S-(Z)-FMMT showed any significant striatal localization in vivo. (author)

  14. Position emission tomography with or without computed tomography in the primary staging of Hodgkin's lymphoma

    DEFF Research Database (Denmark)

    Hutchings, Martin; Loft, Annika; Hansen, Mads

    2006-01-01

    BACKGROUND AND OBJECTIVES: In order to receive the most appropriate therapy, patients with Hodgkin's lymphoma (HL) must be accurately stratified into different prognostic staging groups. Computed tomography (CT) plays a pivotal role in the conventional staging. The aim of the present study...... was to investigate the value of positron emission tomography using 2-[18F]fluoro-2-deoxy-D-glucose (FDG-PET) and combined FDG-PET/CT for the staging of HL patients, and the impact on the choice of treatment. DESIGN AND METHODS: Ninety-nine consecutive, prospectively included patients had FDG-PET and CT...

  15. Parametric imaging of the rate constant K[sub i] using 18Fluoro-L-dopa positron emission tomography in progressive supranuclear palsy

    Energy Technology Data Exchange (ETDEWEB)

    Cordes, M. (Neurodegenerative Disorders Centre, Univ. Hospital, Univ. of British Columbia, Vancouver, BC (Canada) Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf-Virchow, Berlin (Germany)); Snow, B.J. (Neurodegenerative Disorders Centre, Univ. Hospital, Univ. of British Columbia, Vancouver, BC (Canada)); Morrison, S. (TRIUMF, Univ. of British Columbia, Vancouver, BC (Canada)); Sossi, V. (TRIUMF, Univ. of British Columbia, Vancouver, BC (Canada)); Ruth, T.J. (TRIUMF, Univ. of British Columbia, Vancouver, BC (Canada)); Calne, D.B. (Neurodegenerative Disorders Centre, Univ. Hospital, Univ. of British Columbia, Vancouver, BC (Canada))

    1993-01-01

    Positron emission tomography (PET) studies using 18F-L-dopa were carried out in 9 patients with supranuclear palsy and 13 controls. For quantification of PET data a rate constant K[sub i] was calculated for the radiotracer using a graphical method. Corrections for nonspecific activity were performed in both arterial plasma and brain tissue. The purpose of this study was to test the hypothesis that parametric images of the rate constant K mapping can be obtained on a pixel-by-pixel basis using an appropriate mathematical algorithm. K[sub i] values from these parametric images and the graphical approach were compared. Both correlated closely, with y=0.013+0.947[sup *]x, r=0.992 and y=-0.052+1.048[sup *]x, r=0.965 in patients and controls, respectively. Contrast measurements were also performed and showed a striking increase in contrast on parametric images. K mapping offers several advantages over the graphical approach, since parametric images are time-independent, i.e. one image represents the quantitative result of the study. In addition, parmetric images of the rate constant are normalized to arterial plasma radioactivity and corrected for tissue metabolites. Thus, parametric images of K[sub i] in different individuals can be compared directly without further processing in order to assess the nigrostriatal integrity. (orig.)

  16. Value of adjuvant misonidazole in the definitive irradiation of advanced head and neck squamous cancer: an RTOG pilot study (78-02)

    International Nuclear Information System (INIS)

    Fazekas, J.T.; Goodman, R.L.; McLean, C.J.

    1981-01-01

    This RTOG Phase II trial was instituted to determine the toxicity and potential value of the electron-affinic agent, Misonidazole, adjunctive to definitive radiotherapy of T3 and T4 squamous cancers of the oral cavity, oropharynx, or hypopharynx. The fractionation schema was altered to deliver two separate treatments (250 rad and 210 rad) on each day when Misonidazole was administered, while maintaining relatively ''standard'' fractionation (5 fractions and 1000 rad per week). In order to achieve effective enhancement while minimizing toxicity, Misonidazole doses were limited to 2.5 gm/m 2 once per week, not to exceed 24 gm total cumulative in 6 weeks. The dosage was reduced to 2.0 gm/m 2 /wk after the first 30 patients were entered. Among the 50 patients entered, toxicity was confined to the nervous system, with one-third of the patients experiencing mild or moderate peripheral neuropathies and an equal number developing nausea and/or vomiting following p.o. drug administration. Encephalopathy occurred in 10% of the 30 patients receiving 2.5 mg/m 2 dosage. Serum drug levels and cumulative Misonidazole doses did not correlate well with toxicity or response except in comparison of the ''no response'' to the ''complete response'' categories. Immediate mucosal and skin reactions were not enhanced and unusual late normal tissue effects were not encountered. Complete disappearance of all visible and palpable primary tumor was noted in 67% of the 36 patients who completed the adjuvant sensitizer program. Tumor response and survival did not generally correlate with measured (serum) Misonidazole concentration; recurrence was also independent of these measured levels. These preliminary results seemed sufficiently encouraging to warrant a Phase III (randomized) study, now underway by the RTOG

  17. The role of (18)F-FDG positron emission tomography in the follow-up of liver tumors treated with (90)Yttrium radioembolization.

    Science.gov (United States)

    Bagni, Oreste; Filippi, Luca; Schillaci, Orazio

    2015-01-01

    In the last years, radioembolization (RE) has emerged as a novel technique for the treatment of malignant hepatic lesions using (90)Y embedded in spheres, which are infused directly into the hepatic arterial circulation. (90)Y-spheres, once implanted in liver, can release a significant radiation burden to neoplastic cells with a relative low dose to normal parenchyma. (90)Y RE results as a combination of embolization and radiation therapy, thus the standard radiologic follow up modalities may be not sufficiently accurate to assess tumor response to treatment. (18)Fluoro-deoxyglucose Positron Emission Tomography ((18)F-FDG PET) detects glucose uptake and metabolic activity in tumor cells. (18)F-FDG PET has become a well established diagnostic tool in many oncological scenarios. Furthermore, PET response criteria (PERCIST) have been recently introduced to categorize the metabolic response to therapy of cancer patients. Several semiquantitative parameters, such as SUVmax and its changes, the Functional Tumor Volume and the Total Lesion Glycolysis can be useful to accurately assess tumor changes after therapy. The purpose of this article is to present the literature on the role of (18)F-FDG PET in the evaluation of patients with primary and secondary liver tumors treated with (90)Y RE.

  18. High energy positron imaging

    International Nuclear Information System (INIS)

    Chen Shengzu

    2003-01-01

    The technique of High Energy Positron Imaging (HEPI) is the new development and extension of Positron Emission Tomography (PET). It consists of High Energy Collimation Imaging (HECI), Dual Head Coincidence Detection Imaging (DHCDI) and Positron Emission Tomography (PET). We describe the history of the development and the basic principle of the imaging methods of HEPI in details in this paper. Finally, the new technique of the imaging fusion, which combined the anatomical image and the functional image together are also introduced briefly

  19. Scintillators for positron emission tomography

    International Nuclear Information System (INIS)

    Moses, W.W.; Derenzo, S.E.

    1995-09-01

    Like most applications that utilize scintillators for gamma detection, Positron Emission Tomography (PET) desires materials with high light output, short decay time, and excellent stopping power that are also inexpensive, mechanically rugged, and chemically inert. Realizing that this ''ultimate'' scintillator may not exist, this paper evaluates the relative importance of these qualities and describes their impact on the imaging performance of PET. The most important PET scintillator quality is the ability to absorb 511 keV photons in a small volume, which affects the spatial resolution of the camera. The dominant factor is a short attenuation length (≤ 1.5 cm is required), although a high photoelectric fraction is also important (> 30% is desired). The next most important quality is a short decay time, which affects both the dead time and the coincidence timing resolution. Detection rates for single 511 keV photons can be extremely high, so decay times ≤ 500 ns are essential to avoid dead time losses. In addition, positron annihilations are identified by time coincidence so ≤5 ns fwhm coincidence pair timing resolution is required to identify events with narrow coincidence windows, reducing contamination due to accidental coincidences. Current trends in PET cameras are toward septaless, ''fully-3D'' cameras, which have significantly higher count rates than conventional 2-D cameras and so place higher demands on scintillator decay time. Light output affects energy resolution, and thus the ability of the camera to identify and reject events where the initial 511 keV photon has undergone Compton scatter in the patient. The scatter to true event fraction is much higher in fully-3D cameras than in 2-D cameras, so future PET cameras would benefit from scintillators with a 511 keV energy resolution < 10--12% fwhm

  20. Instrumentation optimization for positron emission mammography

    International Nuclear Information System (INIS)

    Moses, William W.; Qi, Jinyi

    2003-01-01

    The past several years have seen designs for PET cameras optimized to image the breast, commonly known as Positron Emission Mammography or PEM cameras. The guiding principal behind PEM instrumentation is that a camera whose field of view is restricted to a single breast has higher performance and lower cost than a conventional PET camera. The most common geometry is a pair of parallel planes of detector modules, although geometries that encircle the breast have also been proposed. The ability of the detector modules to measure the depth of interaction (DOI) is also a relevant feature. This paper finds that while both the additional solid angle coverage afforded by encircling the breast and the decreased blurring afforded by the DOI measurement improve performance, the ability to measure DOI is more important than the ability to encircle the breast

  1. Minimally invasive input function for 2-{sup 18}F-fluoro-A-85380 brain PET studies

    Energy Technology Data Exchange (ETDEWEB)

    Zanotti-Fregonara, Paolo [National Institute of Mental Health, NIH, Molecular Imaging Branch, Bethesda, MD (United States); Maroy, Renaud; Peyronneau, Marie-Anne; Trebossen, Regine [CEA, DSV, I2BM, Service Hospitalier Frederic Joliot, Orsay (France); Bottlaender, Michel [CEA, DSV, I2BM, NeuroSpin, Gif-sur-Yvette (France)

    2012-04-15

    Quantitative neuroreceptor positron emission tomography (PET) studies often require arterial cannulation to measure input function. While population-based input function (PBIF) would be a less invasive alternative, it has only rarely been used in conjunction with neuroreceptor PET tracers. The aims of this study were (1) to validate the use of PBIF for 2-{sup 18}F-fluoro-A-85380, a tracer for nicotinic receptors; (2) to compare the accuracy of measures obtained via PBIF to those obtained via blood-scaled image-derived input function (IDIF) from carotid arteries; and (3) to explore the possibility of using venous instead of arterial samples for both PBIF and IDIF. Ten healthy volunteers underwent a dynamic 2-{sup 18}F-fluoro-A-85380 brain PET scan with arterial and, in seven subjects, concurrent venous serial blood sampling. PBIF was obtained by averaging the normalized metabolite-corrected arterial input function and subsequently scaling each curve with individual blood samples. IDIF was obtained from the carotid arteries using a blood-scaling method. Estimated Logan distribution volume (V{sub T}) values were compared to the reference values obtained from arterial cannulation. For all subjects, PBIF curves scaled with arterial samples were similar in shape and magnitude to the reference arterial input function. The Logan V{sub T} ratio was 1.00 {+-} 0.05; all subjects had an estimation error <10%. IDIF gave slightly less accurate results (V{sub T} ratio 1.03 {+-} 0.07; eight of ten subjects had an error <10%). PBIF scaled with venous samples yielded inaccurate results (V{sub T} ratio 1.13 {+-} 0.13; only three of seven subjects had an error <10%). Due to arteriovenous differences at early time points, IDIF could not be calculated using venous samples. PBIF scaled with arterial samples accurately estimates Logan V{sub T} for 2-{sup 18}F-fluoro-A-85380. Results obtained with PBIF were slightly better than those obtained with IDIF. Due to arteriovenous concentration

  2. MRI and {sup 18}F-fluorodeoxyglucose positron emission tomography in hemimegalencephaly

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, K.T.; Liebig, T.; Hosten, N. [Departments of Radiology and Nuclear Medicine, Virchow-Klinikum, Charite, Berlin (Germany); Amthauer, H.; Farahati, J.; Felix, R. [Departments of Radiology and Nuclear Medicine, Virchow-Klinikum, Charite, Berlin (Germany); PET-Centre Berlin, Virchow-Klinikum, Charite, Humboldt-University, Berlin (Germany); Etou, A.; Lehmann, T.N. [Department of Neurosurgery, Virchow-Klinikum, Charite, Humboldt-University, Berlin (Germany)

    2000-10-01

    We report hemimegalencephaly in a 44-year-old woman with mental retardation, epilepsy and a mild hemiparesis. In addition to typical findings on MRI, 2-deoxy-2[{sup 18}F]fluorodeoxyglucose positron-emission tomography (PET) demonstrated glucose hypometabolism of the affected hemisphere. The results of PET have been coregistered with morphological information from the MRI studies by image fusion. (orig.)

  3. A feature point identification method for positron emission particle tracking with multiple tracers

    Energy Technology Data Exchange (ETDEWEB)

    Wiggins, Cody, E-mail: cwiggin2@vols.utk.edu [University of Tennessee-Knoxville, Department of Physics and Astronomy, 1408 Circle Drive, Knoxville, TN 37996 (United States); Santos, Roque [University of Tennessee-Knoxville, Department of Nuclear Engineering (United States); Escuela Politécnica Nacional, Departamento de Ciencias Nucleares (Ecuador); Ruggles, Arthur [University of Tennessee-Knoxville, Department of Nuclear Engineering (United States)

    2017-01-21

    A novel detection algorithm for Positron Emission Particle Tracking (PEPT) with multiple tracers based on optical feature point identification (FPI) methods is presented. This new method, the FPI method, is compared to a previous multiple PEPT method via analyses of experimental and simulated data. The FPI method outperforms the older method in cases of large particle numbers and fine time resolution. Simulated data show the FPI method to be capable of identifying 100 particles at 0.5 mm average spatial error. Detection error is seen to vary with the inverse square root of the number of lines of response (LORs) used for detection and increases as particle separation decreases. - Highlights: • A new approach to positron emission particle tracking is presented. • Using optical feature point identification analogs, multiple particle tracking is achieved. • Method is compared to previous multiple particle method. • Accuracy and applicability of method is explored.

  4. Photon emission by electrons and positrons traversing thin single crystal

    International Nuclear Information System (INIS)

    Ol'chak, A.S.

    1984-01-01

    Radiation emission by planar channeled particles (electrons, positrons) in a thin single crystal of thickness L is considered. It is shown that for L approximately πb/THETAsub(L) (b is the lattice constant, THETA sub(L) the Lindhard angle) besides the main spontaneous channeling maxima there exist auxiliary interference maxima, the positions of all the maxima depending on L. The dependence of the radiation spectral intensity on crystal thickness is discussed

  5. Positron-emission tomography imaging of long-term shape recognition challenges

    OpenAIRE

    Rosier, A.; Cornette, L.; Dupont, P.; Bormans, G.; Michiels, J.; Mortelmans, L.; Orban, G. A.

    1997-01-01

    Long-term visual memory performance was impaired by two types of challenges: a diazepam challenge on acquisition and a sensory challenge on recognition. Using positron-emission tomography regional cerebral blood flow imaging, we studied the effect of these challenges on regional brain activation during the delayed recognition of abstract visual shapes as compared with a baseline fixation task. Both challenges induced a significant decrease in differential activation in the left fusiform gyrus...

  6. Positron emission tomography of malignant tumours at head and neck. Evaluation of the diagnostic value of positron emission tomography by comparison with computed tomography; Positronenemissionstomographie bei malignen Tumoren im Kopf- und Halsbereich. Beurteilung der diagnostischen Wertigkeit der Positronenemissionstomographie im Vergleich zur Computertomographie

    Energy Technology Data Exchange (ETDEWEB)

    Kettler, Nele

    2011-12-02

    Imaging methods for early, accurate diagnosis and aftercare of malignant growths is currently one of the most important research topics. The objective of this thesis is to evaluate the diagnostic value of FDG-positron emission tomography by comparison with computed tomography for patients with squamous cell carcinoma, malignant melanoma or sarcoma at head and neck. Measurement criteria are sensitivity and specificity. A retrospective evaluation of 100 examinations on 85 patients of University clinic Aachen was performed. The examination reports were supported by reports from histology, positron emission tomography and computed tomography. In each case, the histological results were assumed to provide a reliable benchmark. Sensitivity and specificity for the primary tumour site, metastatic lymphatic nodes and defined anatomic structures were compared across all patients. Comparisons were also performed on sub groups separated by gender, cancer type and the time and frequency at which tumours arose. The statistic analysis was done with MedCalc. Results: The results for sensitivity and specificity of the primary tumour site were 86.42% and 42.86%, and 64.71% and 66.07%, for positron emission tomography and computed tomography respectively. The results for the lymphatic nodes were 51.52% and 92.86% and 64.71% and 66.07%. When the constituent anatomic structures were evaluated separately, the specificity was significantly higher. The separation by gender showed no difference. Because the classification by tumor type resulted in samples that were of varying size, a comparison was difficult. For the diagnosis of primary tumours, the examination with positron emission tomography was superior, whereas computed tomography proved more effective for the diagnosis of recurrent tumours. For the diagnosis of the main tumour site, both methods were shown to be equally suitable. For the assessment of lymphatic nodes, positron emission tomography was superior to computed tomography

  7. Correlation of PET and AMS analyses for early kinetics of 2-fluoro-2-deoxyglucose (FDG)

    International Nuclear Information System (INIS)

    Minamimoto, Ryogo; Hamabe, Yoshimi; Miyaoka, Teiji; Theeraladanon, Chumpol; Oka, Takashi; Matsui, Takao; Inoue, Tomio

    2010-01-01

    The draft of the guidelines for microdosing in clinical trials was published in Japan in 2008 following the guidelines of the European Medicines Agency (EMEA) and the Food and Drug Administration (FDA). It recommends utilizing accelerator mass spectrometry (AMS), liquid chromatography/mass spectrometry (LC/MS/MS), and positron emission tomography (PET) for monitoring drug metabolites in preclinical studies. In this study, we clarified the correlation in measuring result between PET and AMS. The AMS measurement was undergone by using AMS system of Institute of Accelerator Analysis Ltd. (IAA, Kawasaki, Japan). First the back ground 14 C level of blood in mice was measured by AMS. Second, we clarified the relationship between AMS and PET by using 2-fluoro-2-deoxyglucose (FDG). The correlation coefficient (r) of the measurements using PET ( 18 F-FDG) and AMS ( 14 C-FDG) were quite high at 0.97 (Y = 7.54E - 05X + 0.02, p 18 F-FDG was nearly identical with that of 14 C-FDG. These results indicate that the AMS analysis has excellent correlation with the PET method.

  8. Correlation of PET and AMS analyses for early kinetics of 2-fluoro-2-deoxyglucose (FDG)

    Science.gov (United States)

    Minamimoto, Ryogo; Hamabe, Yoshimi; Miyaoka, Teiji; Theeraladanon, Chumpol; Oka, Takashi; Matsui, Takao; Inoue, Tomio

    2010-04-01

    The draft of the guidelines for microdosing in clinical trials was published in Japan in 2008 following the guidelines of the European Medicines Agency (EMEA) and the Food and Drug Administration (FDA). It recommends utilizing accelerator mass spectrometry (AMS), liquid chromatography/mass spectrometry (LC/MS/MS), and positron emission tomography (PET) for monitoring drug metabolites in preclinical studies. In this study, we clarified the correlation in measuring result between PET and AMS. The AMS measurement was undergone by using AMS system of Institute of Accelerator Analysis Ltd. (IAA, Kawasaki, Japan). First the back ground 14C level of blood in mice was measured by AMS. Second, we clarified the relationship between AMS and PET by using 2-fluoro-2-deoxyglucose (FDG). The correlation coefficient ( r) of the measurements using PET ( 18F-FDG) and AMS ( 14C-FDG) were quite high at 0.97 ( Y = 7.54 E - 05 X + 0.02, p blood clearance profile of 18F-FDG was nearly identical with that of 14C-FDG. These results indicate that the AMS analysis has excellent correlation with the PET method.

  9. Revisiting the prognostic value of preoperative 18F-fluoro-2-deoxyglucose (18F-FDG) positron emission tomography (PET) in early-stage (I and II) non-small cell lung cancers (NSCLC)

    International Nuclear Information System (INIS)

    Agarwal, Mohit; Brahmanday, Govinda; Bajaj, Sunil K.; Wong, Ching-Yee Oliver; Ravikrishnan, K.P.

    2010-01-01

    The aims were to determine if the maximum standardized uptake value (SUV max ) of the primary tumor as determined by preoperative 18 F-fluoro-2-deoxyglucose ( 18 F-FDG) positron emission tomography (PET) is an independent predictor of overall survival and to assess its prognostic value after stratification according to pathological staging. A retrospective clinicopathologic review of 363 patients who had a preoperative 18 F-FDG PET done before undergoing attempted curative resection for early-stage (I and II) non-small cell lung cancer (NSCLC) was performed. Patients who had received any adjuvant or neoadjuvant chemotherapy or radiation therapy were excluded. The primary outcome measure was duration of overall survival. Receiver-operating characteristic (ROC) curves were plotted to find out the optimal cutoff values of SUV max yielding the maximal sensitivity plus specificity for predicting the overall survival. Survival curves stratified by median SUV max and optimal cutoff SUV max were estimated by the Kaplan-Meier method and statistical differences were assessed using the log-rank test. Multivariate proportional hazards (Cox) regression analyses were applied to test the SUV max 's independency of other prognostic factors for the prediction of overall survival. The median duration of follow-up was 981 days (2.7 years). The median SUV max was 5.9 for all subjects, 4.5 for stage IA, 8.4 for stage IB, and 10.9 for stage IIB. The optimal cutoff SUV max was 8.2 for all subjects. No optimal cutoff could be established for specific stages. In univariate analyses, each doubling of SUV max [i.e., each log (base 2) unit increase in SUV max ] was associated with a 1.28-fold [95% confidence interval (CI): 1.03-1.59, p = 0.029] increase in hazard of death. Univariate analyses did not show any significant difference in survival by SUV max when data were stratified according to pathological stage (p = 0.119, p = 0.818, and p = 0.882 for stages IA, IB, and IIB, respectively

  10. 18F-fluorodeoxyglucose positron emission tomography predicts survival of patients with neuroendocrine tumors

    DEFF Research Database (Denmark)

    Binderup, Tina; Knigge, Ulrich; Loft, Annika

    2010-01-01

    PURPOSE: (18)F-fluorodeoxyglucose positron emission tomography (FDG-PET) is currently not used on a routine basis for imaging of neuroendocrine (NE) tumors. The aim of this study was to investigate the prognostic value of FDG-PET in patients with NE tumors. EXPERIMENTAL DESIGN: Ninety...

  11. Preparation of radiopharmaceuticals labelled with bromine positron emitting isotopes for the study of dopaminergic receptors of the central nervous system using positron emission tomography

    International Nuclear Information System (INIS)

    Loc'h, C.

    1988-04-01

    The in vivo study of dopaminergic receptors of the central nervous system using positron emission tomography requires the preparation of radiopharmaceuticals labelled with β + emitting isotopes. The chemical and pharmacological properties of these ligands are evaluated. Cyclotron produced 75 and 76 bromine β + emitting isotopes are incorporated into dopaminergic ligands by electrophilic substitution using peracetic acid in a no-carrier added form. Purity, lipophilicity and specific activity are analyzed. Pharmacological criteria (specificity, saturability, displacement, localization) required for ligand-receptor binding studies are evaluated in vitro on striatal membranes and in vivo in the rat. Positron emission tomographic studies show that the study of dopaminergic D2 receptors is possible using 75 and 76 bromine labelled bromospiperone and bromolisuride. These ligands are used in physiological and pharmacological studies of the central nervous system [fr

  12. Positron astronomy with SPI/INTEGRAL

    International Nuclear Information System (INIS)

    Weidenspointner, G.; Diehl, R.; Strong, A.; Weidenspointner, G.; Skinner, G.K.; Skinner, G.K.; Jean, P.; Knoedlseder, J.; Von Ballmoos, P.; Cordier, B.; Schanne, S.; Winkler, C.

    2008-01-01

    We provide an overview of positron astronomy results that have been obtained using the INTEGRAL spectrometer SPI, and discuss their implications for the still mysterious origin of positrons in our Galaxy. It has long been known that the 511 keV positron annihilation emission is strongest from the central region of our Galaxy. Recently, it has been discovered with the SPI spectrometer that the weaker 511 keV line emission from the inner Galactic disk appears to be asymmetric, with the emission to the west of the Galactic center being about twice as strong than that to the east. This distribution of positron annihilation resembles that of low mass X-ray binaries as observed with the INTEGRAL imager IBIS at hard X-ray energies, suggesting that these systems could provide a significant portion of the positrons in our Galaxy. In addition, the spectrometer SPI has permitted unprecedented spectroscopy of annihilation radiation from the bulge and disk regions of the Galaxy, which commences to yield important insights into the conditions of the medium in which the positrons annihilate. (authors)

  13. RANDOM COPOLYMER BLENDS OF STYRENE, PARA-FLUORO STYRENE AND ORTHO-FLUORO STYRENE

    NARCIS (Netherlands)

    OUDHUIS, AACM; TENBRINKE, G; KARASZ, FE

    1993-01-01

    This study completes the investigation of the phase behaviour of polymer blends involving styrene (S), ortho-fluoro styrene (oFS) and para-fluoro styrene (pFS). As before, due to the proximity of the glass transition temperatures of most blends investigated, the miscibility or immiscibility is

  14. Comparing staging by positron emission tomography with contrast-enhanced computed tomography and by pathology in head and neck squamous cell carcinoma.

    Science.gov (United States)

    Qualliotine, J R; Mydlarz, W K; Chan, J Y K; Zhou, X; Wang, H; Agrawal, N

    2015-12-01

    This study aimed to evaluate the ability of positron emission tomography with contrast-enhanced computed tomography to correctly stage head and neck squamous cell carcinomas, in comparison with pathological staging. Positron emission tomography computed tomography was used to determine the tumour-node-metastasis classification and overall cancer stage in 85 head and neck squamous cell carcinoma patients who underwent pre-operative imaging using this modality and primary surgery between July 2010 and January 2013. Staging by positron emission tomography computed tomography was retrospectively compared with staging using pathological specimens. Agreement between imaging stage and pathological stage was examined by univariate and multivariate analysis both overall and for each primary tumour site. This imaging modality was 87.5 per cent sensitive and 44.8 per cent specific in identifying regional cervical metastases, and had false positive and false negative rates of 18.8 per cent and 8.2 per cent, respectively. The positive predictive and negative predictive values were 75.4 per cent and 65.0 per cent, respectively. Univariate and multivariate analyses revealed a significant agreement between positron emission tomography computed tomography and pathological node classification in older patients and for the oral cavity primary tumour site. There was significant agreement between both methods in the overall classification only for tumours classified as T3 or greater. Positron emission tomography computed tomography should be used with caution for the pre-operative staging of head and neck cancers because of its high false positive and false negative rates.

  15. Evaluation of F-18-labeled 5-iodocytidine ({sup 18}F-FIAC) as a new potential positron emission tomography probe for herpes simplex virus type 1 thymidine kinase imaging

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Pei-Chia; Wu, Chun-Yi; Chang, Wen-Yi; Chang, Wei-Ting [Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei, 11221, Taiwan (China); Alauddin, Mian [Department of Experimental Diagnostic Imaging, MD Anderson Cancer Center, University of Texas, TX, 77054 (United States); Liu, Ren-Shan [Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei, 11221, Taiwan (China); Department of Nuclear Medicine, Faculty of Medicine, National Yang-Ming University, Taipei, 11221, Taiwan (China); Department of Nuclear Medicine and National PET/Cyclotron Center, Taipei Veterans General Hospital, Taipei, 11217, Taiwan (China); Lin, Wuu-Jyh [Institute of Nuclear Energy Research, Atomic Energy Council, Taoyuan, 32546, Taiwan (China); Chen, Fu-Du [College of Health and Leisure Science, TransWorld University, Yunlin, 64063, Taiwan (China); Chen, Chuan-Lin, E-mail: clchen2@ym.edu.tw [Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei, 11221, Taiwan (China); Wang, Hsin-Ell, E-mail: hewang@ym.edu.tw [Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei, 11221, Taiwan (China)

    2011-10-15

    Objective: Herpes simplex virus type 1 thymidine kinase (HSV1-tk) gene in combination with radiolabeled nucleoside substrates is the most widely used reporter system. This study characterized 1-(2'-deoxy-2'-[{sup 18}F]fluoro-{beta}-D-arabinofuranosyl)-5-iodocytosine ({sup 18}F-FIAC) as a new potential positron emission tomography (PET) probe for HSV1-tk gene imaging and compared it with 2'-deoxy-2'-[{sup 18}F]fluoro-5-iodo-1-{beta}-D-arabinofuranosyluracil ({sup 18}F-FIAU) and 2'-deoxy-2'-[{sup 18}F]fluoro-5-ethyl-1-{beta}-D-arabinofuranosyluracil({sup 18}F-FEAU) (thymidine analogues) in an NG4TL4-WT/STK sarcoma-bearing mouse model. Methods: A cellular uptake assay, biodistribution study, radioactive metabolites assay and microPET imaging of NG4TL4-WT/STK tumor-bearing mice post administration of {sup 18}F-FIAC, {sup 18}F-FIAU and {sup 18}F-FEAU were conducted to characterize the biological properties of these tracers. Results: Highly specific uptake of {sup 18}F-FIAC, {sup 18}F-FIAU and {sup 18}F-FEAU in tk-transfected [tk(+)] cells was observed. The tk(+)-to-tk(-) cellular uptake ratio after a 2-h incubation was 66.6{+-}25.1, 76.3{+-}18.2 and 247.2{+-}37.2, respectively. In biodistribution studies, {sup 18}F-FIAC showed significant tk(+) tumor specificity (12.6; expressed as the tk(+)-to-tk(-) tumor uptake ratio at 2 h postinjection) comparable with {sup 18}F-FIAU (15.8) but lower than {sup 18}F-FEAU (48.0). The results of microPET imaging also revealed the highly specific accumulation of these three radioprobes in the NG4TL4-tk(+) tumor. Conclusion: Our findings suggested that the cytidine analogue {sup 18}F-FIAC is a new potential PET probe for the imaging of HSV1-tk gene expression. {sup 18}F-FIAC may be regarded as the prodrug of {sup 18}F-FIAU in vivo.

  16. Time-of-Flight Positron Emission Tomography with Radiofrequency Phototube

    International Nuclear Information System (INIS)

    Margaryan, A.; Kakoyan, V.; Knyazyan, S.

    2011-01-01

    In this paper γ-detector, based on the radiofrequency (RF) phototube and recently developed fast and ultrafast scintillators, is considered for Time-of-Flight positron emission tomography applications. Timing characteristics of such a device has been investigated by means of a dedicated Monte Carlo code based on the single photon counting concept. Biexponential timing model for scintillators have been used. The calculations have shown that such a timing model is in a good agreement with recently measured data. The timing resolution of -detectors can be significantly improved by using the RF phototube. (authors)

  17. Low-resource synchronous coincidence processor for positron emission tomography

    International Nuclear Information System (INIS)

    Sportelli, Giancarlo; Belcari, Nicola; Guerra, Pedro; Santos, Andres

    2011-01-01

    We developed a new FPGA-based method for coincidence detection in positron emission tomography. The method requires low device resources and no specific peripherals in order to resolve coincident digital pulses within a time window of a few nanoseconds. This method has been validated with a low-end Xilinx Spartan-3E and provided coincidence resolutions lower than 6 ns. This resolution depends directly on the signal propagation properties of the target device and the maximum available clock frequency, therefore it is expected to improve considerably on higher-end FPGAs.

  18. Functional imaging of the brain with positron emission tomography

    International Nuclear Information System (INIS)

    Alavi, A.; Reivich, M.; Jones, S.C.; Greenberg, J.H.; Wolf, A.P.

    1982-01-01

    An extensive review, with 191 references, of the development and diagnostic use of positron emission tomography (PET) of the brain is presented. An historical overview of functional studies of the brain reviews the use of nitrons oxide, 85 Kr and 133 Xe, [ 14 C]2-deoxyglucose, and [ 18 F]FDG. The [ 18 F]FDG technique allows the investigation of the effects of physiologic stimulation on the brain. Several studies using this technique are reported. The effects of stroke, seizure disorders, aging and dementia, and schizophrenia on cerebral metabolism as demosntrated by PET are explored

  19. Positron emission tomography/magnetic resonance hybrid scanner imaging of cerebral blood flow using 15O-water positron emission tomography and arterial spin labeling magnetic resonance imaging in newborn piglets

    DEFF Research Database (Denmark)

    Andersen, Julie B; Henning, William S; Lindberg, Ulrich

    2015-01-01

    Abnormality in cerebral blood flow (CBF) distribution can lead to hypoxic-ischemic cerebral damage in newborn infants. The aim of the study was to investigate minimally invasive approaches to measure CBF by comparing simultaneous (15)O-water positron emission tomography (PET) and single TI pulsed...

  20. A multicrystal two dimensional BGO detector system for positron emission tomography

    International Nuclear Information System (INIS)

    Casey, M.E.; Nutt, R.

    1986-01-01

    This paper presents a discussion of a new multicrystal detector system as it is implemented in Positron Emission Tomography. The system consists of a 32 x 8 matrix of BGO crystals, a tuned light pipe, and four photomultipliers. The electronics that decodes the position consists of fast preamps, gated integrators, and level comparators. This detector represents a major development toward reducing the cost of PET

  1. Positron Emission Tomography/Magnetic Resonance Imaging for Local Tumor Staging in Patients With Primary Breast Cancer: A Comparison With Positron Emission Tomography/Computed Tomography and Magnetic Resonance Imaging.

    Science.gov (United States)

    Grueneisen, Johannes; Nagarajah, James; Buchbender, Christian; Hoffmann, Oliver; Schaarschmidt, Benedikt Michael; Poeppel, Thorsten; Forsting, Michael; Quick, Harald H; Umutlu, Lale; Kinner, Sonja

    2015-08-01

    This study aimed to assess the diagnostic performance of integrated positron emission tomography (PET)/magnetic resonance imaging (MRI) of the breast for lesion detection and local tumor staging of patients with primary breast cancer in comparison to PET/computed tomography (CT) and MRI. The study was approved by the local institutional review board. Forty-nine patients with biopsy-proven invasive breast cancer were prospectively enrolled in our study. All patients underwent a PET/CT, and subsequently, a contrast-enhanced PET/MRI of the breast after written informed consent was obtained before each examination. Two radiologists independently evaluated the corresponding data sets (PET/CT, PET/MRI, and MRI) and were instructed to identify primary tumors lesions as well as multifocal/multicentric and bilateral disease. Furthermore, the occurrence of lymph node metastases was assessed, and the T-stage for each patient was determined. Histopathological verification of the local tumor extent and the axillary lymph node status was available for 30 of 49 and 48 of 49 patients, respectively. For the remaining patients, a consensus characterization was performed for the determination of the T-stage and nodal status, taking into account the results of clinical staging, PET/CT, and PET/MRI examinations. Statistical analysis was performed to test for differences in diagnostic performance between the different imaging procedures. P values less than 0.05 were considered to be statistically significant. Positron emission tomography/MRI and MRI correctly identified 47 (96%) of the 49 patients with primary breast cancer, whereas PET/CT enabled detection of 46 (94%) of 49 breast cancer patients and missed a synchronous carcinoma in the contralateral breast in 1 patient. In a lesion-by-lesion analysis, no significant differences could be obtained between the 3 imaging procedures for the identification of primary breast cancer lesions (P > 0.05). Positron emission tomography/MRI and

  2. 18F-FDG PET/CT-based early treatment response evaluation of nanoparticle-assisted photothermal cancer therapy.

    Directory of Open Access Journals (Sweden)

    Kamilla Norregaard

    Full Text Available Within the field of nanoparticle-assisted photothermal cancer therapy, focus has mostly been on developing novel heat-generating nanoparticles with the right optical and dimensional properties. Comparison and evaluation of their performance in tumor-bearing animals are commonly assessed by changes in tumor volume; however, this is usually a late-occurring event. This study implements 2-deoxy-2-[F-18]fluoro-D-glucose positron emission tomography imaging to perform early evaluation of the treatment outcome of photothermal therapy. Silica-gold nanoshells (NS are administered intravenously to nude mice bearing human neuroendocrine tumor xenografts and the tumors are irradiated by a near-infrared laser. The animals are positron emission tomography scanned with 2-deoxy-2-[F-18]fluoro-D-glucose one day before and one day after treatment. Using this setup, a significant decrease in tumor uptake of 2-deoxy-2-[F-18]fluoro-D-glucose is found already one day after therapy in the group receiving NS and laser treatment compared to control animals. At this time point no change in tumor volume can be detected. Moreover, the change in tumor uptake, is used to stratify the animals into responders and non-responders, where the responding group matched improved survival. Overall, these findings support the use of 2-deoxy-2-[F-18]fluoro-D-glucose positron emission tomography imaging for preclinical and clinical evaluation and optimization of photothermal therapy.

  3. Value of adjuvant misonidazole in the definitive irradiation of advanced head and neck squamous cancer: an RTOG pilot study (number78-02)

    International Nuclear Information System (INIS)

    Fazekas, J.T.; Goodman, R.L.; McLean, C.J.

    1981-01-01

    This RTOG Phase II trial was instituted to determine the toxicity and potential value of the electron-affinic agent, Misonidazole, adjunctive to definitive radiotherapy of T3 and T4 squamous cancers of the oral cavity, oropharynx, or hypopharynx. The fractionation schema was altered to deliver two separate treatments (250 rad and 210 rad) on each day when Misonidazole was administered, while maintaining relatively ''standard'' fractionation (5 fractions and 1000 rad per week). In order to achieve effective enhancement while minimizing toxicity, Misonidazole doses were limited to 2.5 gm/m 2 once per week, not to exceed 24 gm total cumulative in 6 weeks. Definitive radiation therapy in the range of 6500-7000 rad was delivered over 6 1/2-8 weeks. The dosage was reduced to 1.0 gm/m 2 /wk after the first 30 patients were entered. Among the 50 patients entered, toxicity was confined to the nervous system, with one-third of the patients experiencing mild or moderate peripheral neuropathies (paresthesias, numbness) and an equal number developing nausea and/or vomiting following p.o. drug administration. Encelphalopathy occurred in 10% of the 30 patients receiving 2.5 mg/m 2 dosage. Serum drug levels and cumulative Misonidazole doses did not correlate well with toxicity or response except in comparison of the ''no response'' to the ''complete response'' categories. Immediate mucosal and skin reactions were not enhanced and unusual late normal tissue effects were not encountered. Complete disappearance of all visible and palpable primary tumor was noted in 67% of the 36 patients who completed the adjuvant sensitizer program. Tumor response and survival did not generally correlate with measured (serum) Misonidazole concentration; recurrence was also independent of these measured levels

  4. Performance evaluation of BGO block detectors used in positron emission tomography and a coincidence system

    International Nuclear Information System (INIS)

    Kim, J. H.; Choi, Y.; Lim, K. C.; Lee, M. Y.; Woo, S. K.; Lee, K. H.; Kim, S. E.; Choi, Y. S.; Kim, B. T.

    1999-01-01

    We investigated the basic performances of the BGO block detectors, which is used in the GE Advance positron emission tomography. The block detector is composed of 36 small BGO crystals coupled to two 2-channel photomultiplier tubes. In this study, we measured the crystal map and the intrinsic energy resolution of the detector. The coincidence signals between the detectors were also obtained using F-18. The intrinsic energy resolution of the block detector was 69% FWHM at 140 keV and 33% FWHM at 511 keV. High quality crystal map and the coincidence signals between the detectors were successfully obtained. The timing resolution of the detectors are being measured. The results of this study demonstrate the feasibility of developing high performance positron emission tomography

  5. Studies of positron induced luminescence from polymers

    International Nuclear Information System (INIS)

    Xu, J.; Hulett, L.D. Jr.; Lewis, T.A.; Tolk, N.H.

    1994-01-01

    Light emission from polymers (anthracene dissolved in polystryrene) induced by low-energy positrons and electrons has been studied. Results indicate a clear difference between optical emissions under positron and electron bombardment. The positron-induced luminescence spectrum is believed to be generated by both collisional and annihilation processes

  6. Contribution of positron emission tomography in pleural disease.

    Science.gov (United States)

    Duysinx, B; Corhay, J-L; Larock, M-P; Withofs, N; Bury, T; Hustinx, R; Louis, R

    2010-10-01

    Positron emission tomography (PET) now plays a clear role in oncology, especially in chest tumours. We discuss the value of metabolic imaging in characterising pleural pathology in the light of our own experience and review the literature. PET is particularly useful in characterising malignant pleural pathologies and is a factor of prognosis in mesothelioma. Metabolic imaging also provides clinical information for staging lung cancer, in researching the primary tumour in metastatic pleurisy and in monitoring chronic or recurrent pleural pathologies. PET should therefore be considered as a useful tool in the diagnosis of liquid or solid pleural pathologies. Copyright © 2010 SPLF. Published by Elsevier Masson SAS. All rights reserved.

  7. Kinetic modeling in pre-clinical positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kuntner, Claudia [AIT Austrian Institute of Technology GmbH, Seibersdorf (Austria). Biomedical Systems, Health and Environment Dept.

    2014-07-01

    Pre-clinical positron emission tomography (PET) has evolved in the last few years from pure visualization of radiotracer uptake and distribution towards quantification of the physiological parameters. For reliable and reproducible quantification the kinetic modeling methods used to obtain relevant parameters of radiotracer tissue interaction are important. Here we present different kinetic modeling techniques with a focus on compartmental models including plasma input models and reference tissue input models. The experimental challenges of deriving the plasma input function in rodents and the effect of anesthesia are discussed. Finally, in vivo application of kinetic modeling in various areas of pre-clinical research is presented and compared to human data.

  8. Combined use of positron emission tomography and volume doubling time in lung cancer screening with low-dose CT scanning

    DEFF Research Database (Denmark)

    Ashraf, H; Dirksen, A; Jakobsen, Annika Loft

    2011-01-01

    In lung cancer screening the ability to distinguish malignant from benign nodules is a key issue. This study evaluates the ability of positron emission tomography (PET) and volume doubling time (VDT) to discriminate between benign and malignant nodules.......In lung cancer screening the ability to distinguish malignant from benign nodules is a key issue. This study evaluates the ability of positron emission tomography (PET) and volume doubling time (VDT) to discriminate between benign and malignant nodules....

  9. Positron emission tomography of the heart

    International Nuclear Information System (INIS)

    Schelbert, H.R.; Phelps, M.E.; Kuhl, D.E.

    1979-01-01

    Positron emission computed tomography (PCT) represents an important new tool for the noninvasive evaluation and, more importantly, quantification of myocardial performance. Most currently available techniques permit assessment of only one aspect of cardiac function, i.e., myocardial perfusion by gamma scintillation camera imaging with Thallium-201 or left ventricular function by echocardiography or radionuclide angiocardiography. With PCT it may become possible to study all three major segments of myocardial performance, i.e., regional blood flow, mechanical function and, most importantly, myocardial metabolism. Each of these segments can either be evaluated separately or in combination. This report briefly describes the principles and technological advantages of the imaging device, reviews currently available radioactive tracers and how they can be employed for the assessment of flow, function and metabolism; and, lastly, discusses possible applications of PCT for the study of cardiac physiology or its potential role in the diagnosis of cardiac disease

  10. Positron emission tomography of the heart

    Energy Technology Data Exchange (ETDEWEB)

    Schelbert, H.R.; Phelps, M.E.; Kuhl, D.E.

    1979-01-01

    Positron emission computed tomography (PCT) represents an important new tool for the noninvasive evaluation and, more importantly, quantification of myocardial performance. Most currently available techniques permit assessment of only one aspect of cardiac function, i.e., myocardial perfusion by gamma scintillation camera imaging with Thallium-201 or left ventricular function by echocardiography or radionuclide angiocardiography. With PCT it may become possible to study all three major segments of myocardial performance, i.e., regional blood flow, mechanical function and, most importantly, myocardial metabolism. Each of these segments can either be evaluated separately or in combination. This report briefly describes the principles and technological advantages of the imaging device, reviews currently available radioactive tracers and how they can be employed for the assessment of flow, function and metabolism; and, lastly, discusses possible applications of PCT for the study of cardiac physiology or its potential role in the diagnosis of cardiac disease.

  11. A positron emission tomography study of wind-up pain in chronic postherniotomy pain

    DEFF Research Database (Denmark)

    Kupers, Ron; Lonsdale, Markus Georg; Aasvang, Eske Kvanner

    2011-01-01

    -induced wind-up pain in neuropathic pain patients. We therefore used positron emission tomography (PET) to investigate the cerebral response pattern of mechanical wind-up pain in a homogenous group of 10 neuropathic pain patients with long-standing postherniotomy pain in the groin area. Patients were scanned...

  12. Combined computed tomography and fluorodeoxyglucose positron emission tomography in the diagnosis of prosthetic valve endocarditis: a case series.

    Science.gov (United States)

    Bartoletti, Michele; Tumietto, Fabio; Fasulo, Giovanni; Giannella, Maddalena; Cristini, Francesco; Bonfiglioli, Rachele; Raumer, Luigi; Nanni, Cristina; Sanfilippo, Silvia; Di Eusanio, Marco; Scotton, Pier Giorgio; Graziosi, Maddalena; Rapezzi, Claudio; Fanti, Stefano; Viale, Pierluigi

    2014-01-13

    The diagnosis of prosthetic valve endocarditis is challenging. The gold standard for prosthetic valve endocarditis diagnosis is trans-esophageal echocardiography. However, trans-esophageal echocardiography may result in negative findings or yield images difficult to differentiate from thrombus in patients with prosthetic valve endocarditis. Combined computed tomography and fluorodeoxyglucose positron emission tomography is a potentially promising diagnostic tool for several infectious conditions and it has also been employed in patients with prosthetic valve endocarditis but data are still scant. We reviewed the charts of 6 patients with prosthetic aortic valves evaluated for suspicion of prosthetic valve endocarditis, at two different hospital, over a 3-year period. We found 3 patients with early-onset PVE cases and blood cultures yielding Pseudomonas aeruginosa, Staphylococcus epidermidis and Staphylococcus lugdunensis, respectively; and 3 late-onset cases in the remaining 3 patients with isolation in the blood of Streptococcus bovis, Candida albicans and P. aeruginosa, respectively. Initial trans-esophageal echocardiography was negative in all the patients, while fluorodeoxyglucose positron emission tomography showed images suspicious for prosthetic valve endocarditis. In 4 out of 6 patients valve replacement was done with histology confirming the prosthetic valve endocarditis diagnosis. After an adequate course of antibiotic therapy fluorodeoxyglucose positron emission tomography showed resolution of prosthetic valve endocarditis in all the patients. Our experience confirms the potential role of fluoroseoxyglucose positron emission tomography in the diagnosis and follow-up of prosthetic valve endocarditis.

  13. Derisking the Cu-Mediated 18F-Fluorination of Heterocyclic Positron Emission Tomography Radioligands.

    Science.gov (United States)

    Taylor, Nicholas J; Emer, Enrico; Preshlock, Sean; Schedler, Michael; Tredwell, Matthew; Verhoog, Stefan; Mercier, Joel; Genicot, Christophe; Gouverneur, Véronique

    2017-06-21

    Molecules labeled with fluorine-18 ( 18 F) are used in positron emission tomography to visualize, characterize and measure biological processes in the body. Despite recent advances in the incorporation of 18 F onto arenes, the development of general and efficient approaches to label radioligands necessary for drug discovery programs remains a significant task. This full account describes a derisking approach toward the radiosynthesis of heterocyclic positron emission tomography (PET) radioligands using the copper-mediated 18 F-fluorination of aryl boron reagents with 18 F-fluoride as a model reaction. This approach is based on a study examining how the presence of heterocycles commonly used in drug development affects the efficiency of 18 F-fluorination for a representative aryl boron reagent, and on the labeling of more than 50 (hetero)aryl boronic esters. This set of data allows for the application of this derisking strategy to the successful radiosynthesis of seven structurally complex pharmaceutically relevant heterocycle-containing molecules.

  14. GABA-A stimulation in normal volunteers and during temporal epilepsy measured by 18FDG with positron emission tomography

    International Nuclear Information System (INIS)

    Cinotti, L.; Le Bars, D.; Garcia-Larrea, L.; Peyron, R.; Gregoire, M.C.; Lavenne, F.; Comar, D.; Mauguiere, F.; Krogsgaard-Larsen, P.

    1996-01-01

    The γ-amino butyric acid (GABA) is the principal inhibitory neurotransmitter of the brain and it has been evoked in epilepto-genesis. Using a GABA analog, the THIP, we tried to establish if the gabaergic neurotransmission was modified in the epileptic focus. For this purpose, we measured the effects of this specific GABA agonist on the cerebral glucose consumption (CMRGlu) as measured by 18F-fluoro-deoxyglucose ( 18 FDG) with positron emission tomography (PET). Eight patients presenting temporal epilepsy and three normal volunteers received two 18 FDG PET studies, after placebo and THIP injection, in random order. Clinical symptoms and electroencephalographic data demonstrated a trend towards sleepiness and a diminution of alpha waves after THIP injection. CMRGlu was globally increased with THIP in cortical regions, cerebellum and caudate nuclei. The average increase was 17% in grey matter while it did not reach significancy in white matter. Under the placebo condition, the asymmetry between the focus and the controlateral internal temporal zone was 18% as an average, and reduced significantly to 11% after THIP injection. In the external temporal zones, the asymmetry decreased from 28% to 14%. These results suggest that gabaergic inhibition requires energy in the normal brain tissue and in this with temporal epilepsy. Since the asymmetry of glucose consumption tends to diminish, the inhibitory GABA system appears preserved in temporal epilepsy with an enhanced sensitivity in the focus. (Authors). 6 refs., 4 figs

  15. Comparison study of positron emission tomography, X-ray CT and MRI in Parkinsonism with dementia

    International Nuclear Information System (INIS)

    Okada, Junichi; Peppard, R.; Calne, D.B.

    1989-01-01

    Brain atrophy and local cerebral metabolic rate of glucose (LCMR-glc) in Parkinson's disease with dementia and Parkinsonism-dementia complex (PDC) were studied using positron emission tomography (PET) with F-18-2-deoxy-2-fluoro-D-glucose, X-ray CT and magnetic resonance imaging (MRI). The group of Parkinson's disease with dementia (n=7) had a significantly decreased LCMR-glc in all regions when compared with the age-matched normal group. In the group of Parkinson's disease without dementia (n=6), LCMR-glc was also significantly lower than the control group, although it was higher than the group with associated dementia. Some of the normal aged persons had cortical atrophy. There was no correlation between LCMR-glc and cortical atrophy. Six Guamnian patients had PDC associated with amyotrophic lateral sclerosis (ALS), and four patients had it without ALS. LCMR-glc did not differ in the two groups. It was, however, significantly lower than that in 5 Guamanian and 10 Caucasian normal persons. The group of PDC had a noticeable cortical atrophy and ventricular dilatation, regardless of the presence or absence of ALS. There was correlation between decrease of LCMR-glc and cortical atrophy of the frontal, parietal and temporal lobes. Parkinson's disease and PDC were different from Alzheimer's disease in which a decreased LCMR-glc has been reported to be usually confined to the cerebral cortex. Cortical atrophy and ventricular dilatation were depicted on MRI and CT in the PDC group, but did not in the group of Parkinson's disease. PET was useful in the functional examination and both MRI and CT were useful in the anatomical examination of these diseases. (Namekawa, K)

  16. Rapid detection of human infections with fluorine-18 fluorodeoxyglucose and positron emission tomography: preliminary results

    International Nuclear Information System (INIS)

    Sugawara, Yoshifumi; Kison, P.V.; Russo, J.E.; Zasadny, K.R.; Braun, D.K.; Wahl, R.L.

    1998-01-01

    The purpose of this study was to evaluate the feasibility of 2-[fluorine-18]fluoro-2-deoxy-d-glucose (FDG) and positron emission tomography (PET) for rapid detection of human infections. Eleven patients who were known or suspected to be harboring various infections were studied with FDG-PET. Dynamic scans over the putative infection sites were performed immediately after FDG (370 MBq) injection through 60 min, and static images including multiple projection images were then obtained. FDG uptake was assessed visually into four grades (0, normal; 1, probably normal; 2, probably abnormal; 3, definitely abnormal). For the semiquantitative index of FDG uptake in infections, the standardized uptake value of FDG normalized to the predicted lean body mass (SUV-lean, SUL) was determined from the images obtained at 50-60 min after FDG injection. PET results were compared with final clinical diagnoses. Eleven lesions in eight patients, which were interpreted as grade 2 or 3 by FDG-PET, were all concordant with active infectious foci. The SUL values of infections ranged from 0.97 to 6.69. In two patients, FDG-PET correctly showed no active infection. In one patient, it was difficult to detect infectious foci by FDG-PET due to substantial normal background uptake of FDG. In total, FDG-PET correctly diagnosed the presence or absence of active infection in 10 of 11 patients. Fusion images of PET with computed tomography showed the most intense FDG uptake to be within an abscess wall. In conclusion, FDG-PET appears to be a promising modality for rapid imaging of active human infections. More extensive clinical evaluation is warranted to determine the accuracy of this method. (orig.)

  17. Comparison study of positron emission tomography, X-ray CT and MRI in Parkinsonism with dementia

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Junichi; Peppard, R; Calne, D B

    1989-05-01

    Brain atrophy and local cerebral metabolic rate of glucose (LCMR-glc) in Parkinson's disease with dementia and Parkinsonism-dementia complex (PDC) were studied using positron emission tomography (PET) with F-18-2-deoxy-2-fluoro-D-glucose, X-ray CT and magnetic resonance imaging (MRI). The group of Parkinson's disease with dementia (n=7) had a significantly decreased LCMR-glc in all regions when compared with the age-matched normal group. In the group of Parkinson's disease without dementia (n=6), LCMR-glc was also significantly lower than the control group, although it was higher than the group with associated dementia. Some of the normal aged persons had cortical atrophy. There was no correlation between LCMR-glc and cortical atrophy. Six Guamnian patients had PDC associated with amyotrophic lateral sclerosis (ALS), and four patients had it without ALS. LCMR-glc did not differ in the two groups. It was, however, significantly lower than that in 5 Guamanian and 10 Caucasian normal persons. The group of PDC had a noticeable cortical atrophy and ventricular dilatation, regardless of the presence or absence of ALS. There was correlation between decrease of LCMR-glc and cortical atrophy of the frontal, parietal and temporal lobes. Parkinson's disease and PDC were different from Alzheimer's disease in which a decreased LCMR-glc has been reported to be usually confined to the cerebral cortex. Cortical atrophy and ventricular dilatation were depicted on MRI and CT in the PDC group, but did not in the group of Parkinson's disease. PET was useful in the functional examination and both MRI and CT were useful in the anatomical examination of these diseases. (Namekawa, K).

  18. Small animal positron emission tomography imaging and in vivo studies of atherosclerosis

    DEFF Research Database (Denmark)

    Hag, Anne Mette Fisker; Ripa, Rasmus Sejersten; Pedersen, Sune Folke

    2013-01-01

    Atherosclerosis is a growing health challenge globally, and despite our knowledge of the disease has increased over the last couple of decades, many unanswered questions remain. As molecular imaging can be used to visualize, characterize and measure biological processes at the molecular and cellu...... knowledge obtained from in vivo positron emission tomography studies of atherosclerosis performed in small animals....

  19. Radiotherapy in combination with misonidazole and ACNU (1-(4 amino-2 methyl-5 pyrimidinyl) methyl-3-(2 chloroethyl)-3-nitrosourea hydrochloride)

    Energy Technology Data Exchange (ETDEWEB)

    Asakura, Hideo; Mashima, Yasuoki; Kanazawa, Atsuko (Toranomon Hospital, Tokyo (Japan)); Maruhashi, Akira

    1983-11-01

    Misonidazole and ACNU were intermittently combined one or several times with radiotherapy. Misonidazole was orally administered with a dose of 1.5g/m/sup 2/ 4 hours before irradiation. ACNU with a dose of 60mg/m/sup 2/ mixed with predonisolone (40 mg) was intravenously injected between misonidazole and irradiation. Irradiation was carried out with the fractionation of 120 rads per fraction and 5 fractions per week in lung cancer and of 200 rads per fraction and 3 fractions per week in head and neck cancer. Twenty lung cancer patients and 13 head and neck cancer patients were treated from July, 1980 to April, 1982. In lung cancer, BAI (bronchial artery infusion) of adriamycin was added besides the above-mentioned treatment. Complete plus partial response rate of lung cancer was 85%, one year survival rate by Kaplan-Meier's method 65 +- 10.7% and two year survival rate 39.8 +- 12.2%, which were promising. In head and neck cancer, complete plus partial response rate was 76.9%, and one year survival rate 67.3 +- 13.6%. Head and neck cancer contained many recurrent and many advanced stage cases. Side effects of this treatment were nausea, vomiting and thrombocytopenia due to ACNU. These were all transient. Any peripheral neuropathy due to misonidazole was not observed in this treatment scheme. The fractionation in multomodality therapy is discussed and the mechanism of chemosensitization is bibliographically discussed.

  20. Activity-based costing evaluation of a [F-18]-fludeoxyglucose positron emission tomography study

    NARCIS (Netherlands)

    Krug, Bruno; Van Zanten, Annie; Pirson, Anne-Sophie; Crott, Ralph; Vander Borght, Thierry

    2009-01-01

    Objective: The aim of the study is to use the activity-based costing approach to give a better insight in the actual cost structure of a positron emission tomography procedure (FDG-PET) by defining the constituting components and by simulating the impact of possible resource or practice changes.

  1. Fluorine-18 fluorodeoxyglucose positron emission tomography-computed tomography in evaluation of residual intramuscular myxoma

    International Nuclear Information System (INIS)

    Zade, Anand; Ahire, Archana; Shetty, Shishir; Rai, Sujith; Bokka, Rajashekharrao; Velumani, Arokiaswamy; Kabnurkar, Rasika

    2015-01-01

    Intramuscular myxoma (IM) is a rare benign neoplasm. In a patient diagnosed with IM of left thigh, we report the utility of a postoperative fluorine-18 fluorodeoxyglucose positron emission tomography-computed tomography scan in assessing the efficacy of surgical excision

  2. A prospective study of 2-[F-18] fluoro-2-deoxy-D-glucose/positron emission tomography scan, Tc-99m-labeled arcitumomab (CEA-scan), and blind second-look laparotomy for detecting colon cancer recurrence in patients with increasing carcinoembryonic antigen levels

    Czech Academy of Sciences Publication Activity Database

    Libutti, S. K.; Alexander, HR.; Choyke, P.; Bartlett, DL.; Bacharach, SL.; Whatley, M.; Jousse, F.; Eckelman, WC.; Kranda, Karel; Neumann, RD.; Carrasquillo, JA.

    2001-01-01

    Roč. 8, č. 10 (2001), s. 779-786 ISSN 1068-9265 R&D Projects: GA AV ČR KSK4055109 Keywords : carcinoembryonic antigen * positron emission tomography * FDG Subject RIV: FD - Oncology ; Hematology Impact factor: 3.308, year: 2001

  3. Origin and annihilation physics of positrons in the Galaxy

    International Nuclear Information System (INIS)

    Alexis, Anthony

    2014-01-01

    A gamma radiation at 511 keV is observed since the early 1970's toward the Galactic bulge region. This emission is the signature of a large number of electron-positron annihilations, the positron being the electron's antiparticle. Unfortunately, the origin of the positrons responsible for this emission is still a mystery. Many positron-source candidates have been suggested but none of them can account for the galactic annihilation emission. The spatial distribution of this emission is indeed very atypical. Since 2002, the SPI spectrometer onboard the INTEGRAL space laboratory revealed an emission strongly concentrated toward the galactic bulge and a weaker emission from the galactic disk. This morphology is unusual because it does not correspond to any of the known galactic astrophysical-object or interstellar-matter distributions. The assumption that positrons annihilate close to their sources (i.e. the spatial distribution of the annihilation emission reflects the spatial distribution of the sources) has consequently been called into question. Recent studies suggest that positrons could propagate far away from their sources before annihilating. This physical aspect could be the key point to solve the riddle of the galactic positron origin. This thesis is devoted to the modelling of the propagation and annihilation of positrons in the Galaxy, in order to compare simulated spatial models of the annihilation emission with recent measurements provided by SPI/INTEGRAL. This method allows to put constraints on the origin of galactic positrons. We therefore developed a propagation Monte-Carlo code of positrons within the Galaxy in which we implemented all the theoretical and observational knowledge about positron physics (sources, transport modes, energy losses, annihilation modes) and the interstellar medium of our Galaxy (interstellar gas distributions, galactic magnetic fields, structures of the gaseous phases). Due to uncertainties in several physical parameters

  4. Utility of positron emission tomography for tumour surveillance in children with neurofibromatosis type 1

    Energy Technology Data Exchange (ETDEWEB)

    Moharir, Mahendranath [Hospital for Sick Children, Division of Neurology, Ontario (Canada); London, Kevin [Children' s Hospital at Westmead, Department of Nuclear Medicine, Sydney (Australia); Howman-Giles, Robert [University of Sydney, Discipline of Imaging, Faculty of Medicine, Sydney (Australia); North, Kathryn [Children' s Hospital at Westmead, Institute for Neuroscience and Muscle Research, Sydney, NSW (Australia)

    2010-07-15

    There is little consensus regarding optimal surveillance of optic pathway glioma (OPG) and plexiform neurofibroma (PNF) in childhood neurofibromatosis type 1 (NF1). {sup 18}F-2-Fluoro-2-deoxy-D-glucose (FDG) positron emission tomography and computed tomography (PET/CT) is employed in the surveillance of adult PNFs; but its utility has neither been specifically studied in children with PNFs nor in children with OPG. Review of PET/CT studies was performed in NF1 children with OPG or PNF. FDG-avidity of tumours was semi-quantitatively analysed and graded by calculating the maximum standardised uptake value (SUV{sub max}) [grade 1: <3 (low), grade 2: >3-<4 (intermediate), grade 3: >4 (intense)]. Eighteen children (ten girls; median age: 8.5-years) had PET/CT. Nineteen OPGs were imaged. The SUV{sub max} could be measured in 16. Ten were grade 1 and three each were grade 2 and grade 3. FDG-avidity reduced from grade 3 to grade 1 in two symptomatic OPGs following chemotherapy and this was associated with clinical improvement. PET/CT diagnosed symptomatic OPGs with a sensitivity of 0.625 [95% confidence interval (CI): 0.259-0.897] and specificity of 0.875 (95% CI: 0.466-0.993). Sixteen PNFs were imaged. Twelve were grade 1 and two each were grade 2 and grade 3. The two grade 3 PNFs were confirmed malignant peripheral nerve sheath tumours. PET/CT diagnosed malignant transformation with a sensitivity of 1.0 (95% CI: 0.197-1.0) and specificity of 0.857 (95% CI: 0.561-0.974). PET/CT may contribute useful information to the surveillance of OPG in childhood NF1 - particularly to identify progressive, symptomatic tumours. As in adults, PET/CT is useful for the detection of malignant transformation in PNFs in children with NF1. (orig.)

  5. Utility of positron emission tomography for tumour surveillance in children with neurofibromatosis type 1

    International Nuclear Information System (INIS)

    Moharir, Mahendranath; London, Kevin; Howman-Giles, Robert; North, Kathryn

    2010-01-01

    There is little consensus regarding optimal surveillance of optic pathway glioma (OPG) and plexiform neurofibroma (PNF) in childhood neurofibromatosis type 1 (NF1). 18 F-2-Fluoro-2-deoxy-D-glucose (FDG) positron emission tomography and computed tomography (PET/CT) is employed in the surveillance of adult PNFs; but its utility has neither been specifically studied in children with PNFs nor in children with OPG. Review of PET/CT studies was performed in NF1 children with OPG or PNF. FDG-avidity of tumours was semi-quantitatively analysed and graded by calculating the maximum standardised uptake value (SUV max ) [grade 1: 3- 4 (intense)]. Eighteen children (ten girls; median age: 8.5-years) had PET/CT. Nineteen OPGs were imaged. The SUV max could be measured in 16. Ten were grade 1 and three each were grade 2 and grade 3. FDG-avidity reduced from grade 3 to grade 1 in two symptomatic OPGs following chemotherapy and this was associated with clinical improvement. PET/CT diagnosed symptomatic OPGs with a sensitivity of 0.625 [95% confidence interval (CI): 0.259-0.897] and specificity of 0.875 (95% CI: 0.466-0.993). Sixteen PNFs were imaged. Twelve were grade 1 and two each were grade 2 and grade 3. The two grade 3 PNFs were confirmed malignant peripheral nerve sheath tumours. PET/CT diagnosed malignant transformation with a sensitivity of 1.0 (95% CI: 0.197-1.0) and specificity of 0.857 (95% CI: 0.561-0.974). PET/CT may contribute useful information to the surveillance of OPG in childhood NF1 - particularly to identify progressive, symptomatic tumours. As in adults, PET/CT is useful for the detection of malignant transformation in PNFs in children with NF1. (orig.)

  6. Dynamic positron emission tomography in man using small bismuth germanate crystals

    International Nuclear Information System (INIS)

    Derenzo, S.E.; Budinger, T.F.; Huesman, R.H.; Cahoon, J.L.

    1982-04-01

    Primary considerations for the design of positron emission tomographs for medical studies in humans are the need for high imaging sensitivity, whole organ coverage, good spatial resolution, high maximum data rates, adequate spatial sampling with minimum mechanical motion, shielding against out of plane activity, pulse height discrimination against scattered photons, and timing discrimination against accidental coincidences. We discuss the choice of detectors, sampling motion, shielding, and electronics to meet these objectives

  7. Transcutaneous measurement of the arterial input function in positron emission tomography

    International Nuclear Information System (INIS)

    Litton, J.E.; Eriksson, L.

    1990-01-01

    Positron emission tomography (PET) provides a powerful tool in medical research. Biochemical function can be both precisely localized and quantitatively measured. To achieve reliable quantitation it is necessary to know the time course of activity concentration in the arterial blood during the measurement. In this study the arterial blood curve from the brachial artery is compared to the activity measured in the internal carotid artery with a new transcutaneous detector

  8. 18 F-Labeling of Sensitive Biomolecules for Positron Emission Tomography.

    Science.gov (United States)

    Krishnan, Hema S; Ma, Longle; Vasdev, Neil; Liang, Steven H

    2017-11-07

    Positron emission tomography (PET) imaging study of fluorine-18 labeled biomolecules is an emerging and rapidly growing area for preclinical and clinical research. The present review focuses on recent advances in radiochemical methods for incorporating fluorine-18 into biomolecules via "direct" or "indirect" bioconjugation. Recently developed prosthetic groups and pre-targeting strategies, as well as representative examples in 18 F-labeling of biomolecules in PET imaging research studies are highlighted. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Preamputation evaluation of lower-limb skeletal muscle perfusion with H(2) (15)O positron emission tomography.

    Science.gov (United States)

    Scremin, Oscar U; Figoni, Stephen F; Norman, Keith; Scremin, A M Erika; Kunkel, Charles F; Opava-Rutter, Dorene; Schmitter, Eric D; Bert, Alberto; Mandelkern, Mark

    2010-06-01

    To establish whether muscle blood flow (MBF) measurements with O-water positron emission tomography could reliably identify patients with critical limb ischemia and detect and quantify a distal deficit in skeletal MBF in these cases. O-water positron emission tomography scans were performed at rest or during unloaded ankle plantar and dorsiflexion exercise of the diseased leg in 17 subjects with leg ischemia or on a randomly selected leg of 18 age-matched healthy control subjects. TcPO2 was evaluated with Novametrix monitors and perfusion of skin topically heated to 44 degrees C and adjacent nonheated areas with a Moor Instruments laser Doppler imaging scanner. The enhancement of MBF induced by exercise was significantly lower in ischemic than in normal legs, and the sensitivity and specificity of this phenomenon were similar to those of laser Doppler imaging or TcPO2 in identifying ischemia subjects. In addition, the exercise MBF deficit was predominant at the distal-leg levels, indicating the ability of the technique to help determine the correct level of amputation. Skeletal MBF of legs with severe ischemia can be detected accurately with O-water positron emission tomography and could add valuable information about viability of skeletal muscle in the residual limb when deciding the level of an amputation.

  10. Measurement of blood-brain barrier permeability with positron emission tomography in patients with multiple sclerosis

    International Nuclear Information System (INIS)

    Fieschi, C.; Pozzilli, C.; Bernardi, S.; Bozzao, L.; Lenzi, G.L.; Picozzi, P.; Iannotti, F.; Conforti, P.

    1988-01-01

    The purpose of the investigation was to elucidate the role of positron emission tomography using 68 Ga-EDTA in the study of blood-brain barrier abnormalities associated with multiple sclerosis. 14 refs.; 1 figure

  11. Three dimensional positron-CT: 3D-PET

    International Nuclear Information System (INIS)

    Ishii, K.

    2000-01-01

    Positron-CT, namely the positron emission tomograph (PET) provides us the metabolism images obtained by the administration of the drug labeled by the positron emission nuclide in the human body. For example, the carbohydrate metabolism image is obtained by the administration of glucose labelled by 18 F-radioisotopes, and it can be applied to early detection of the cancer and research of high-order function of the brain. As well as X-ray CT, the examine receives the exposure in the positron CT. 3D-PET is based on the solid measurement of γ-rays, therefore, the detection sensitivity of 3D-PET becomes very high and it is possible to drastically reduce the dose of the positron emission nuclide. Because the exposure is reduced to the utmost, the positron CT diagnosis would be possible for the child and the exposure of positron CT doctor in charge can be also reduced. This ideal functional diagnostic imaging equipment, namely, 3D-PET is introduced here. (author)

  12. Monitoring variables affecting positron emission tomography measurements of cerebral blood flow in anaesthetized pigs

    DEFF Research Database (Denmark)

    Alstrup, Aage Kristian Olsen; Zois, Nora Elisabeth; Simonsen, Mette

    Background: Positron emission tomography (PET) imaging of anaesthetised pig brains is a useful tool in neuroscience. Stable cerebral blood flow (CBF) is essential for PET, since variations can affect the kinetics of several radiotracers. However, the impact of physiological factors regulating CBF...

  13. Early positron emission tomography response-adapted treatment in stage I and II hodgkin lymphoma

    DEFF Research Database (Denmark)

    André, Marc P.E.; Girinsky, Théodore; Federico, Massimo

    2017-01-01

    Purpose Patients who receive combined modality treatment for stage I and II Hodgkin lymphoma (HL) have an excellent outcome. Early response evaluation with positron emission tomography (PET) scan may improve selection of patients who need reduced or more intensive treatments. Methods We performed...

  14. Characterization of positron emission tomography hypoxia tracer uptake and tissue oxygenation via electrochemical modeling

    NARCIS (Netherlands)

    Bowen, S.R.; Kogel, A.J. van der; Nordsmark, M.; Bentzen, S.M.; Jeraj, R.

    2011-01-01

    PURPOSE: Unique uptake and retention mechanisms of positron emission tomography (PET) hypoxia tracers make in vivo comparison between them challenging. Differences in imaged uptake of two common hypoxia radiotracers, [(61)Cu]Cu-ATSM and [(18)F]FMISO, were characterized via computational modeling to

  15. A positron emission tomography study of cardiac sequelae in children with Kawasaki disease, 1

    International Nuclear Information System (INIS)

    Ohmochi, Yutaka

    1994-01-01

    This study quantitatively measured regional myocardial blood flow (MBF) and perfusable tissue fraction (pTF) in 25 children (mean age: 17.2±2.7) with Kawasaki disease using positron emission tomography and H 2 15 O. Patients were divided into three groups based on coronary angiographic findings. Group 1 consisted of 11 patients with normal coronary angiograms; Group 2, 7 patients with stenotic coronary lesions. There were no significant differences in MBF and pTF among 5 divided regions on the left ventricular wall. Average MBF at rest in Group 1 was 0.91±0.19 ml/min/g. There was a poor correlation between MBF estimated positron emission tomography and patient's age in Group 1. (r=-0.374, Y=-0.0234X + 1.254: p 2 15 O, to determine the functional capacity of coronary artery lesions and myocardial damage in children with Kawasaki disease. (author)

  16. Positron Emission Tomography: Current Challenges and Opportunities for Technological Advances in Clinical and Preclinical Imaging Systems

    Science.gov (United States)

    Vaquero, Juan José; Kinahan, Paul

    2017-01-01

    Positron emission tomography (PET) imaging is based on detecting two time-coincident high-energy photons from the emission of a positron-emitting radioisotope. The physics of the emission, and the detection of the coincident photons, give PET imaging unique capabilities for both very high sensitivity and accurate estimation of the in vivo concentration of the radiotracer. PET imaging has been widely adopted as an important clinical modality for oncological, cardiovascular, and neurological applications. PET imaging has also become an important tool in preclinical studies, particularly for investigating murine models of disease and other small-animal models. However, there are several challenges to using PET imaging systems. These include the fundamental trade-offs between resolution and noise, the quantitative accuracy of the measurements, and integration with X-ray computed tomography and magnetic resonance imaging. In this article, we review how researchers and industry are addressing these challenges. PMID:26643024

  17. Positron Emission Tomography: Current Challenges and Opportunities for Technological Advances in Clinical and Preclinical Imaging Systems.

    Science.gov (United States)

    Vaquero, Juan José; Kinahan, Paul

    2015-01-01

    Positron emission tomography (PET) imaging is based on detecting two time-coincident high-energy photons from the emission of a positron-emitting radioisotope. The physics of the emission, and the detection of the coincident photons, give PET imaging unique capabilities for both very high sensitivity and accurate estimation of the in vivo concentration of the radiotracer. PET imaging has been widely adopted as an important clinical modality for oncological, cardiovascular, and neurological applications. PET imaging has also become an important tool in preclinical studies, particularly for investigating murine models of disease and other small-animal models. However, there are several challenges to using PET imaging systems. These include the fundamental trade-offs between resolution and noise, the quantitative accuracy of the measurements, and integration with X-ray computed tomography and magnetic resonance imaging. In this article, we review how researchers and industry are addressing these challenges.

  18. Cardiological applications of positron emission tomography

    International Nuclear Information System (INIS)

    Schelbert, H.; Czernin, J.

    1994-01-01

    Positron emission tomography (PET) expands the diagnostic possibilities of nuclear medicine techniques for the diagnosis of coronary artery disease and, especially, for the identification of myocardial viability. The presence of coronary artery disease can be detected by evaluation of myocardial blood flow at rest and during pharmacologically induced hyperemia with a sensitivity of 84 to 98% and a specificity of 78 to 100% according to recent studies. Comparative investigations in the same patients have demonstrated a significant gain in the diagnostic accuracy of PET as compared with single photon emission computed tomography (SPECT). PET has influenced even more profoundly the identification of myocardial viability. Measured against the functional outcome of regional contractile function after successful revascularization, an increase of glucose utilization relative to regional myocardial blood flow is 77 to 85% accurate in identifying reversibly injured myocardium. Conversely, PET is 78 to 92% accurate in identifying myocardium as irreversibly injured when pre-operative glucose uptake was reduced or absent. Recent studies have indicated that it is possible to predict to some extent post-revascularization improvement in left ventricular function as well as in congestive heart failure related symptoms in patients with ischemic cardiomyopathy. Furthermore, PET can identify patients with an increased risk of mortality and morbidity as a result of ischemic heart disease and, thus, stratify patients to the most appropriate and cost-effective therapeutic approach. (authors)

  19. A statistical analysis of count normalization methods used in positron-emission tomography

    International Nuclear Information System (INIS)

    Holmes, T.J.; Ficke, D.C.; Snyder, D.L.

    1984-01-01

    As part of the Positron-Emission Tomography (PET) reconstruction process, annihilation counts are normalized for photon absorption, detector efficiency and detector-pair duty-cycle. Several normalization methods of time-of-flight and conventional systems are analyzed mathematically for count bias and variance. The results of the study have some implications on hardware and software complexity and on image noise and distortion

  20. Adjusted scaling of FDG positron emission tomography images for statistical evaluation in patients with suspected Alzheimer's disease.

    Science.gov (United States)

    Buchert, Ralph; Wilke, Florian; Chakrabarti, Bhismadev; Martin, Brigitte; Brenner, Winfried; Mester, Janos; Clausen, Malte

    2005-10-01

    Statistical parametric mapping (SPM) gained increasing acceptance for the voxel-based statistical evaluation of brain positron emission tomography (PET) with the glucose analog 2-[18F]-fluoro-2-deoxy-d-glucose (FDG) in patients with suspected Alzheimer's disease (AD). To increase the sensitivity for detection of local changes, individual differences of total brain FDG uptake are usually compensated for by proportional scaling. However, in cases of extensive hypometabolic areas, proportional scaling overestimates scaled uptake. This may cause significant underestimation of the extent of hypometabolic areas by the statistical test. To detect this problem, the authors tested for hypermetabolism. In patients with no visual evidence of true focal hypermetabolism, significant clusters of hypermetabolism in the presence of extended hypometabolism were interpreted as false-positive findings, indicating relevant overestimation of scaled uptake. In this case, scaled uptake was reduced step by step until there were no more significant clusters of hypermetabolism. In 22 consecutive patients with suspected AD, proportional scaling resulted in relevant overestimation of scaled uptake in 9 patients. Scaled uptake had to be reduced by 11.1% +/- 5.3% in these cases to eliminate the artifacts. Adjusted scaling resulted in extension of existing and appearance of new clusters of hypometabolism. Total volume of the additional voxels with significant hypometabolism depended linearly on the extent of the additional scaling and was 202 +/- 118 mL on average. Adjusted scaling helps to identify characteristic metabolic patterns in patients with suspected AD. It is expected to increase specificity of FDGPET in this group of patients.

  1. FEASIBILITY OF POSITRON EMISSION TOMOGRAPHY OF DOSE DISTRIBUTION IN PROTON BEAM CANCER THERAPY

    International Nuclear Information System (INIS)

    BEEBE-WANG, J.J.; DILMANIAN, F.A.; PEGGS, S.G.; SCHLYEER, D.J.; VASKA, P.

    2002-01-01

    Proton therapy is a treatment modality of increasing utility in clinical radiation oncology mostly because its dose distribution conforms more tightly to the target volume than x-ray radiation therapy. One important feature of proton therapy is that it produces a small amount of positron-emitting isotopes along the beam-path through the non-elastic nuclear interaction of protons with target nuclei such as 12 C, 14 N, and 16 O. These radioisotopes, mainly 11 C, 13 N and 15 O, allow imaging the therapy dose distribution using positron emission tomography (PET). The resulting PET images provide a powerful tool for quality assurance of the treatment, especially when treating inhomogeneous organs such as the lungs or the head-and-neck, where the calculation of the dose distribution for treatment planning is more difficult. This paper uses Monte Carlo simulations to predict the yield of positron emitters produced by a 250 MeV proton beam, and to simulate the productions of the image in a clinical PET scanner

  2. Clinical evaluation of hypoxic cell sensitizer (Misonidazole)

    Energy Technology Data Exchange (ETDEWEB)

    Asakawa, Hiroshi (Miyagi Prefectural Adult Disease Center, Natori (Japan)); Watarai, Jiro; Hoshino, Toshiaki

    1984-06-01

    Clinical effectiveness and toxicity of Misonidazole were analyzed and discussed in 22 cases of carcinoma of uterine cervix, 17 cases of esophageal cancer and 11 with other malignancies treated by radiation. By clinical and histologic examination in the controlled trial, it was shown that radiation response of tumor was slightly sensitized in the treated group with this drug, compared with that in the control group. It was confirmed that there was no significant difference between radiation response of tumor in both groups. Peripheral neuropathy was a complication in 10% and toxicodermatitis in 12% even if the total dose administered was below 10 g/m/sup 2/. From these results, it was strongly suggested that this drug is not suitable in combination with simple fractionated irradiation as a hypoxic cell sensitizer.

  3. Diffuse nesidioblastosis diagnosed on a Ga-68 DOTATATE positron emission tomography/computerized tomography

    International Nuclear Information System (INIS)

    Arun, Sasikumar; Mittal, Bhagwant Rai; Shukla, Jaya; Bhattacharya, Anish; Kumar, Praveen

    2013-01-01

    The authors describe a 50 days old pre-term infant with persistent hyperinsulinemic hypoglycemia of infancy in whom 68 Ga DOTATATE positron emission tomography/computerized tomography scan showed diffusely increased tracer uptake in the entire pancreas with no abnormal tracer uptake anywhere else in the body, suggestive of a diffuse variant of nesidioblastosis. (author)

  4. Fluorodeoxyglucose-based positron emission tomography imaging to monitor drug responses in hematological tumors

    NARCIS (Netherlands)

    Newbold, Andrea; Martin, Ben P.; Cullinane, Carleen; Bots, Michael

    2014-01-01

    Positron emission tomography (PET) can be used to monitor the uptake of the labeled glucose analog fluorodeoxyglucose (¹⁸F-FDG), a process that is generally believed to reflect viable tumor cell mass. The use of ¹⁸F-FDG PET can be helpful in documenting over time the reduction in tumor mass volume

  5. Positron emission tomographic imaging of tumors using monoclonal antibodies. Progress report, April 15, 1992--October 31, 1992

    Energy Technology Data Exchange (ETDEWEB)

    Zalutsky, M.R.

    1992-08-01

    This research project is developing methods for utilizing positron emission tomography (PET) to increase the clinical potential of radiolabeled monoclonal antibodies (MAbs). This report describes the development of methods for labeling MAbs and their fragments with positron-emitting halogen nuclides, fluorine-18 and iodine-124. These nulides were selected because of the widespread availability of F-18 and because of our extensive experience in the development of new protein radiohalogenation methods.

  6. Compressive effect of the magnetic field on the positron range in commonly used positron emitters simulated using Geant4

    Science.gov (United States)

    Li, Chong; Cao, Xingzhong; Liu, Fuyan; Tang, Haohui; Zhang, Zhiming; Wang, Baoyi; Wei, Long

    2017-11-01

    The compressive effect of a magnetic field on the positron range from commonly used positron emitters in PET (Positron Emission Tomography) was simulated using the Geant4 toolkit with H2O as the environmental material. The compression of the positron range, which was different in the directions parallel and perpendicular to the magnetic field, showed finite final variation of relative change rate versus the magnetic field. The variation greatly depended on the positron-emission energy spectrum in the same medium. Furthermore, the volume of the positron annihilation point was dramatically compressed as the magnetic field was set in the range of 3-6T. It was more prominent for 82Rb , which is generally used as a positron source in PET technology.

  7. 18 F-sodium fluoride positron emission tomography of the equine distal limb: Exploratory study in three horses.

    Science.gov (United States)

    Spriet, M; Espinosa, P; Kyme, A Z; Phillips, K L; Katzman, S A; Galuppo, L D; Stepanov, P; Beylin, D

    2018-01-01

    Positron emission tomography (PET) is a cross-sectional, functional imaging modality that has recently become available to the horse. The use of 18 F-sodium fluoride ( 18 F-NaF), a PET bone tracer, has not previously been reported in this species. To assess the feasibility of 18 F-NaF PET in the equine distal limb and explore possible applications in the horse in comparison with other imaging modalities. Exploratory descriptive study involving three research horses. Horses were placed under general anaesthesia prior to intravenous (i.v.) administration of 1.5 MBq/kg of 18 F-NaF. Positron emission tomography imaging of both front feet and fetlocks was performed using a portable scanner. Computed tomography (CT) of the distal limb was performed under a separate anaesthetic episode. Bone scintigraphy and magnetic resonance imaging (MRI) were subsequently performed under standing sedation. Images obtained from PET and other imaging modalities were independently assessed and the results correlated. Positron emission tomography images were obtained without complication. The radiation exposure rate was similar to equine bone scintigraphy. Positron emission tomography detected focal 18 F-NaF uptake in areas where other imaging modalities did not identify any abnormalities. This included sites of ligamentous attachment, subchondral compact bone plate and the flexor cortex of the navicular bone. 18 F-NaF uptake was identified in some, but not all, osseous fragments and areas of osseous formation, suggesting a distinction between active and inactive lesions. A small number of horses were included and histopathology was not available. 18 F-NaF PET imaging of the equine distal limb provides useful additional information when compared with CT, MRI and scintigraphy and has the potential for both research and clinical applications in the horse. The Summary is available in Chinese - see Supporting information. © 2017 EVJ Ltd.

  8. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle W

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present...

  9. Motion correction in thoracic positron emission tomography

    CERN Document Server

    Gigengack, Fabian; Dawood, Mohammad; Schäfers, Klaus P

    2015-01-01

    Respiratory and cardiac motion leads to image degradation in Positron Emission Tomography (PET), which impairs quantification. In this book, the authors present approaches to motion estimation and motion correction in thoracic PET. The approaches for motion estimation are based on dual gating and mass-preserving image registration (VAMPIRE) and mass-preserving optical flow (MPOF). With mass-preservation, image intensity modulations caused by highly non-rigid cardiac motion are accounted for. Within the image registration framework different data terms, different variants of regularization and parametric and non-parametric motion models are examined. Within the optical flow framework, different data terms and further non-quadratic penalization are also discussed. The approaches for motion correction particularly focus on pipelines in dual gated PET. A quantitative evaluation of the proposed approaches is performed on software phantom data with accompanied ground-truth motion information. Further, clinical appl...

  10. Applications of positron emission tomography to psychiatry

    International Nuclear Information System (INIS)

    Volkow, N.D.; Brodie, J.D.; Gomez-mont, F.

    1985-01-01

    The brain's inaccessibility has hampered investigation of the metabolic changes underlying the behavioral and psychological symptoms of psychiatric patients. Using positron emission transaxial tomography (PET) to study the functioning human brain opens the possibility of directly investigating the patterns of activity associated with mental illness. A major focus of present-day research in psychiatry has been to identify etiological agents that fit a medical model of psychiatric illness. Experiments seeking pathophysiological indices that would permit objective classification of psychiatric illnesses have failed to reveal consistent abnormalities. The lack of consistency is explained in part by research designs that deal with the brain as if it were a homogeneous organ. PET offers a unique technique for monitoring the regional biochemical activity that is associated with the different ''brain states'' and ''brain traits'' of normal subjects and psychiatric patients

  11. Positron Emission Tomography (PET) and breast cancer in clinical practice

    International Nuclear Information System (INIS)

    Lavayssiere, Robert; Cabee, Anne-Elizabeth; Filmont, Jean-Emmanuel

    2009-01-01

    The landscape of oncologic practice has changed deeply during the past few years and there is now a need, through a multidisciplinary approach, for imaging to provide accurate evaluation of morphology and function and to guide treatment (Image Guided Therapy). Increasing emphasis has been put on Position Emission Tomography (PET) role in various cancers among clinicians and patients despite a general context of healthcare expenditure limitation. Positron Emission Tomography has currently a limited role in breast cancer, but also general radiologists and specialists should be aware of these indications, especially when staging aggressive cancers and looking for recurrence. Currently, the hybrid systems associating PET and Computed Tomography (CT) and in the same device [Rohren EM, Turkington TG, Coleman RE. Clinical applications of PET in oncology. Radiology 2004;231:305-32; Blodgett TM, Meltzer CM, Townsend DW. PET/CT: form and function. Radiology 2007;242:360-85; von Schulthess GK, Steinert HC, Hany TF. Integrated PET/CT: current applications and futures directions. Radiology 2006;238(2):405-22], or PET-CT, are more commonly used and the two techniques are adding their potentialities. Other techniques, MRI in particular, may also compete with PET in some instance and as far as ionizing radiations dose limitation is considered, some breast cancers becoming some form of a chronic disease. Breast cancer is a very complex, non-uniform, disease and molecular imaging at large may contribute to a better knowledge and to new drugs development. Ongoing research, Positron Emission Mammography (PEM) and new tracers, are likely to bring improvements in patient care [Kelloff GJ, Hoffman JM, Johnson B, et al. Progress and promise of FDG-PET Imaging for cancer patient management and oncologic drug development. Clin Cancer Res 2005;1(April (8)): 2005

  12. Positron Emission Tomography (PET) and breast cancer in clinical practice

    Energy Technology Data Exchange (ETDEWEB)

    Lavayssiere, Robert [Centre d' Imagerie Paris-Nord, 1, avenue Charles Peguy, 95200 Sarcelles (France); Institut du Sein Henri Hartmann (ISHH), 1, rue des Dames Augustines, 92200 Neuilly sur Seine (France)], E-mail: cab.lav@wanadoo.fr; Cabee, Anne-Elizabeth [Centre d' Imagerie Paris-Nord, 1, avenue Charles Peguy, 95200 Sarcelles (France); Institut du Sein Henri Hartmann (ISHH), 1, rue des Dames Augustines, 92200 Neuilly sur Seine (France); Centre RMX, 80, avenue Felix Faure, 75105 Paris (France); Filmont, Jean-Emmanuel [Institut du Sein Henri Hartmann (ISHH), 1, rue des Dames Augustines, 92200 Neuilly sur Seine (France); American Hospital of Paris, Nuclear Medicine, 63, boulevard Victor Hugo - BP 109, 92202 Neuilly sur Seine Cedex (France)

    2009-01-15

    The landscape of oncologic practice has changed deeply during the past few years and there is now a need, through a multidisciplinary approach, for imaging to provide accurate evaluation of morphology and function and to guide treatment (Image Guided Therapy). Increasing emphasis has been put on Position Emission Tomography (PET) role in various cancers among clinicians and patients despite a general context of healthcare expenditure limitation. Positron Emission Tomography has currently a limited role in breast cancer, but also general radiologists and specialists should be aware of these indications, especially when staging aggressive cancers and looking for recurrence. Currently, the hybrid systems associating PET and Computed Tomography (CT) and in the same device [Rohren EM, Turkington TG, Coleman RE. Clinical applications of PET in oncology. Radiology 2004;231:305-32; Blodgett TM, Meltzer CM, Townsend DW. PET/CT: form and function. Radiology 2007;242:360-85; von Schulthess GK, Steinert HC, Hany TF. Integrated PET/CT: current applications and futures directions. Radiology 2006;238(2):405-22], or PET-CT, are more commonly used and the two techniques are adding their potentialities. Other techniques, MRI in particular, may also compete with PET in some instance and as far as ionizing radiations dose limitation is considered, some breast cancers becoming some form of a chronic disease. Breast cancer is a very complex, non-uniform, disease and molecular imaging at large may contribute to a better knowledge and to new drugs development. Ongoing research, Positron Emission Mammography (PEM) and new tracers, are likely to bring improvements in patient care [Kelloff GJ, Hoffman JM, Johnson B, et al. Progress and promise of FDG-PET Imaging for cancer patient management and oncologic drug development. Clin Cancer Res 2005;1(April (8)): 2005].

  13. Positron emission tomography and migraine. Tomographie par emission de positons et migraine

    Energy Technology Data Exchange (ETDEWEB)

    Chabriat, H. (CEA, 91 - Orsay (France). Service Hospitalier Frederic Joliot)

    1992-04-01

    Positron emission tomography (PET) is a brain imaging technique that allows in vivo studies of numerous physiological parameters. There have been few PET studies in migraine patients. Cerebral blood flow changes with no variations in brain oxygen consumption have been reported in patients with prolonged neurologic manifestations during migraine attacks. Parenteral administration of reserpine during migraine headache has been followed by a fall in the overall cerebral uptake of glucose. The small sample sizes and a number of methodologic problems complicate the interpretation of these results. Recent technical advances and the development of new PET tracers can be expected to provide further insight into the pathophysiology of migraine. Today cerebral cortex 5 HT{sub 2} serotonin receptors can be studied in migraine patients with PET.

  14. Estimation of intersubject variability of cerebral blood flow measurements using MRI and positron emission tomography

    DEFF Research Database (Denmark)

    Henriksen, Otto Mølby; Larsson, Henrik B W; Hansen, Adam E

    2012-01-01

    PURPOSE: To investigate the within and between subject variability of quantitative cerebral blood flow (CBF) measurements in normal subjects using various MRI techniques and positron emission tomography (PET). MATERIALS AND METHODS: Repeated CBF measurements were performed in 17 healthy, young...

  15. Positron emission CT and X-ray CT findings in chronic obstructive pulmonary diseases

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Yoshikazu; Murata, Kiyoshi; Ito, Harumi; Senda, Michio; Yonekura, Yoshiharu; Konishi, Junji; Nishimura, Koichi; Izumi, Takahide; Oshima, Shunsaku

    1987-08-01

    Positron emission CT and X-ray CT were performed in fifteen patients with emphysema confirmed SAB and twelve patients with clinical DPB. In patients with emphysema, 20 of 36 areas showed a central pattern and their perfusion scintigrams showed stripe-signs. On the other hand, the patients with DPB showed outer layer progression of the disease.

  16. Statistical properties of compartmental model parameters extracted from dynamic positron emission tomography experiments

    International Nuclear Information System (INIS)

    Mazoyer, B.M.; Huesman, R.H.; Budinger, T.F.; Knittel, B.L.

    1986-01-01

    Over the past years a major focus of research in physiologic studies employing tracers has been the computer implementation of mathematical methods of kinetic modeling for extracting the desired physiological parameters from tomographically derived data. A study is reported of factors that affect the statistical properties of compartmental model parameters extracted from dynamic positron emission tomography (PET) experiments

  17. Optically stimulated luminescence properties of Tm3+ doped KMgF3 fluoro perovskite

    International Nuclear Information System (INIS)

    Camargo, L.; Marcazzo, J.; Perez C, L.; Cruz Zaragoza, E.; Martinez O, S. A.

    2017-10-01

    In this work the optically stimulated luminescence (OSL) properties of undoped and Tm 3+ doped KMgF 3 fluoro perovskite have been investigated for the first time. OSL efficiency for stimulation with different wavelengths has been analyzed for each compound. The maximum OSL emission was found with blue light stimulation. The radioluminescence (Rl) spectra have shown two emission peaks at 455 and 360 nm, which can be ascribed to the 1 D 2 - 3 F 4 and 1 D 2 - 3 H 6 transitions of the Tm 3+ cations. It has been found that doping with Thulium 0.5 mol % renders the most intense OSL emission. Furthermore, several dosimetric properties such as OSL response as a function of dose, reproducibility of the OSL signal after several cycles of irradiation readout and the minimum detectable dose have been investigated. Finally, the OSL response of KMgF 3 : Tm 3+ has been compared to that of commercial Al 2 O 3 :C and the possible application of this fluoro perovskite to OSL dosimetry has been evaluated. (Author)

  18. Comparison study of positron emission tomography, X-ray CT and MRI in Parkinsonism with dementia

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Junichi; Peppard, R.; Calne, D.B.

    1989-05-01

    Brain atrophy and local cerebral metabolic rate of glucose (LCMR-glc) in Parkinson's disease with dementia and Parkinsonism-dementia complex (PDC) were studied using positron emission tomography (PET) with F-18-2-deoxy-2-fluoro-D-glucose, X-ray CT and magnetic resonance imaging (MRI). The group of Parkinson's disease with dementia (n=7) had a significantly decreased LCMR-glc in all regions when compared with the age-matched normal group. In the group of Parkinson's disease without dementia (n=6), LCMR-glc was also significantly lower than the control group, although it was higher than the group with associated dementia. Some of the normal aged persons had cortical atrophy. There was no correlation between LCMR-glc and cortical atrophy. Six Guamnian patients had PDC associated with amyotrophic lateral sclerosis (ALS), and four patients had it without ALS. LCMR-glc did not differ in the two groups. It was, however, significantly lower than that in 5 Guamanian and 10 Caucasian normal persons. The group of PDC had a noticeable cortical atrophy and ventricular dilatation, regardless of the presence or absence of ALS. There was correlation between decrease of LCMR-glc and cortical atrophy of the frontal, parietal and temporal lobes. Parkinson's disease and PDC were different from Alzheimer's disease in which a decreased LCMR-glc has been reported to be usually confined to the cerebral cortex. Cortical atrophy and ventricular dilatation were depicted on MRI and CT in the PDC group, but did not in the group of Parkinson's disease. PET was useful in the functional examination and both MRI and CT were useful in the anatomical examination of these diseases. (Namekawa, K).

  19. Evaluation of brain tumours by positron emission tomography

    International Nuclear Information System (INIS)

    Schober, O.; Meyer, G.J.

    1992-01-01

    The clinical application of positron emission tomography (PET) for the evaluation of brain tumours has proved clinically valuable. Amino acid and FDG-glucose PET provide information on the degree of malignancy and the prognosis during the initial evaluation. After therapy, the residual tumour can be visualized and recurrence can be differentiated from necrosis. Amino acids have advantages over FDG for these clinical applications. Blood flow, oxygen extraction and metabolism and blood-brain barrier permeability are of minor relevance in clinical situations. Comparison of PET with MRI and MRS will provide new data. The quantitative information of the unique information yielded by PET will lead to a more important clinical role, as will the extrapolation of this experience to the SPECT technique. (orig.) [de

  20. Analysis of human cerebral functions using positron emission tomography (PET)

    International Nuclear Information System (INIS)

    Shibasaki, Takashi

    1984-01-01

    Positron emission tomography has two major advantages to analyse human cerebral functions in vivo. First, we can see the distribution of a variety of substance in the living (and doing something) human brain. Positron emitters, 11 C, 13 N, 15 O and 18 F, are made by medical cyclotron and are elements of natural substrates or easily tagged to substrate. Second, the distribution of the tracer is calculated to make a quantitative functional map in a reasonable spatial resolution over the entire brain in the same time. Not only cortical areas but also deeper structures show regional cerebral blood flow (rCBF) or local cerebral metabolic rates (LCMRs). Nowadays, PET is put to practical use for determination of mainly rCBF, LCMR for glucose (LCMRsub(glu)), LCMR for oxygen (LCMRsub(o2)) and regional cerebral blood volume (rCBV). There have been many other pilot studies, such as estimation of distribution of given neurotransmitters or modulators in the brain which also confirms the substances' role in the neuronal function, and observation of protein synthesis relating to memory function. (J.P.N.)

  1. Effect of misonidazole (Ro-07-0582) on the incidence of micronuclei in irradiated Ehrlich tumour ascites cells

    Energy Technology Data Exchange (ETDEWEB)

    Olinici, C D; Mustea, I [Institute of Oncology, Cluj (Romania)

    1978-12-01

    Misonidazole (1-(2-nitro-1-imidazole)-3-methoxy-2-propanol) was injected intraperitoneally into mice on the fifth day of development of Ehrlich ascites tumours. The animals were then /sup 60/Co ..gamma..-irradiated (100 to 400 R) and killed at 24 to 72 hours post-irradiation. Ascites tumour cells from the mice were stained by the Feulgen reaction and the incidence of micronuclei determined. Pretreatment with misonidazole induced an increase in the incidence of micronuclei in the irradiated tumour cells. This increase was most conspicuous at higher radiation doses and at 48 hours post-irradiation. The results suggest the possibility of using the micronucleus assay for the screening of substances with radio-sensitizing potential. The method would be especially suitable for the study of tumours irradiated in vivo with high doses of radiation, since cytogenetic methods present difficulties under these conditions.

  2. Correlation of PET and AMS analyses for early kinetics of 2-fluoro-2-deoxyglucose (FDG)

    Energy Technology Data Exchange (ETDEWEB)

    Minamimoto, Ryogo, E-mail: ryogom@yokohama-cu.ac.j [Department of Radiology, Graduate School of Medicine, Yokohama City University, Yokohama (Japan); Hamabe, Yoshimi; Miyaoka, Teiji [Institute of Accelerator Analysis (IAA) Ltd., Kawasaki (Japan); Theeraladanon, Chumpol; Oka, Takashi [Department of Radiology, Graduate School of Medicine, Yokohama City University, Yokohama (Japan); Matsui, Takao [Institute of Accelerator Analysis (IAA) Ltd., Kawasaki (Japan); Inoue, Tomio [Department of Radiology, Graduate School of Medicine, Yokohama City University, Yokohama (Japan)

    2010-04-15

    The draft of the guidelines for microdosing in clinical trials was published in Japan in 2008 following the guidelines of the European Medicines Agency (EMEA) and the Food and Drug Administration (FDA). It recommends utilizing accelerator mass spectrometry (AMS), liquid chromatography/mass spectrometry (LC/MS/MS), and positron emission tomography (PET) for monitoring drug metabolites in preclinical studies. In this study, we clarified the correlation in measuring result between PET and AMS. The AMS measurement was undergone by using AMS system of Institute of Accelerator Analysis Ltd. (IAA, Kawasaki, Japan). First the back ground {sup 14}C level of blood in mice was measured by AMS. Second, we clarified the relationship between AMS and PET by using 2-fluoro-2-deoxyglucose (FDG). The correlation coefficient (r) of the measurements using PET ({sup 18}F-FDG) and AMS ({sup 14}C-FDG) were quite high at 0.97 (Y = 7.54E - 05X + 0.02, p < 0.001). The blood clearance profile of {sup 18}F-FDG was nearly identical with that of {sup 14}C-FDG. These results indicate that the AMS analysis has excellent correlation with the PET method.

  3. Integration of Quantitative Positron Emission Tomography Absolute Myocardial Blood Flow Measurements in the Clinical Management of Coronary Artery Disease.

    Science.gov (United States)

    Gewirtz, Henry; Dilsizian, Vasken

    2016-05-31

    In the >40 years since planar myocardial imaging with(43)K-potassium was introduced into clinical research and management of patients with coronary artery disease (CAD), diagnosis and treatment have undergone profound scientific and technological changes. One such innovation is the current state-of-the-art hardware and software for positron emission tomography myocardial perfusion imaging, which has advanced it from a strictly research-oriented modality to a clinically valuable tool. This review traces the evolving role of quantitative positron emission tomography measurements of myocardial blood flow in the evaluation and management of patients with CAD. It presents methodology, currently or soon to be available, that offers a paradigm shift in CAD management. Heretofore, radionuclide myocardial perfusion imaging has been primarily qualitative or at best semiquantitative in nature, assessing regional perfusion in relative terms. Thus, unlike so many facets of modern cardiovascular practice and CAD management, which depend, for example, on absolute values of key parameters such as arterial and left ventricular pressures, serum lipoprotein, and other biomarker levels, the absolute levels of rest and maximal myocardial blood flow have yet to be incorporated into routine clinical practice even in most positron emission tomography centers where the potential to do so exists. Accordingly, this review focuses on potential value added for improving clinical CAD practice by measuring the absolute level of rest and maximal myocardial blood flow. Physiological principles and imaging fundamentals necessary to understand how positron emission tomography makes robust, quantitative measurements of myocardial blood flow possible are highlighted. © 2016 American Heart Association, Inc.

  4. 18 F-fluorodeoxyglucose positron emission tomography-computed tomography for preoperative lymph node staging in patients undergoing radical cystectomy for bladder cancer: a prospective study.

    Science.gov (United States)

    Hitier-Berthault, Maryam; Ansquer, Catherine; Branchereau, Julien; Renaudin, Karine; Bodere, Françoise; Bouchot, Olivier; Rigaud, Jérôme

    2013-08-01

    The objective of our study was to analyze the diagnostic performance of (18) F-fluorodeoxyglucose positron emission tomography-computed tomography for lymph node staging in patients with bladder cancer before radical cystectomy and to compare it with that of computed tomography. A total of 52 patients operated on between 2005 and 2010 were prospectively included in this prospective, mono-institutional, open, non-randomized pilot study. Patients who had received neoadjuvant chemotherapy or radiotherapy were excluded. (18) F-fluorodeoxyglucose positron emission tomography-computed tomography in addition to computed tomography was carried out for lymph node staging of bladder cancer before radical cystectomy. Lymph node dissection during radical cystectomy was carried out. Findings from (18) F-fluorodeoxyglucose positron emission tomography-computed tomography and computed tomography were compared with the results of definitive histological examination of the lymph node dissection. The diagnostic performance of the two imaging modalities was assessed and compared. The mean number of lymph nodes removed during lymph node dissection was 16.5 ± 10.9. Lymph node metastasis was confirmed on histological examination in 22 cases (42.3%). This had been suspected in five cases (9.6%) on computed tomography and in 12 cases (23.1%) on (18) F-fluorodeoxyglucose positron emission tomography-computed tomography. Sensitivity, specificity, positive predictive value, negative predictive value, relative risk and accuracy were 9.1%, 90%, 40%, 57.4%, 0.91 and 55.7%, respectively, for computed tomography, and 36.4%, 86.7%, 66.7%, 65%, 2.72, 65.4%, respectively, for (18) F-fluorodeoxyglucose positron emission tomography-computed tomography. (18) F-fluorodeoxyglucose positron emission tomography-computed tomography is more reliable than computed tomography for preoperative lymph node staging in patients with invasive bladder carcinoma undergoing radical cystectomy. © 2012 The Japanese

  5. Sensitivity estimation in time-of-flight list-mode positron emission tomography.

    Science.gov (United States)

    Herraiz, J L; Sitek, A

    2015-11-01

    An accurate quantification of the images in positron emission tomography (PET) requires knowing the actual sensitivity at each voxel, which represents the probability that a positron emitted in that voxel is finally detected as a coincidence of two gamma rays in a pair of detectors in the PET scanner. This sensitivity depends on the characteristics of the acquisition, as it is affected by the attenuation of the annihilation gamma rays in the body, and possible variations of the sensitivity of the scanner detectors. In this work, the authors propose a new approach to handle time-of-flight (TOF) list-mode PET data, which allows performing either or both, a self-attenuation correction, and self-normalization correction based on emission data only. The authors derive the theory using a fully Bayesian statistical model of complete data. The authors perform an initial evaluation of algorithms derived from that theory and proposed in this work using numerical 2D list-mode simulations with different TOF resolutions and total number of detected coincidences. Effects of randoms and scatter are not simulated. The authors found that proposed algorithms successfully correct for unknown attenuation and scanner normalization for simulated 2D list-mode TOF-PET data. A new method is presented that can be used for corrections for attenuation and normalization (sensitivity) using TOF list-mode data.

  6. Sensitivity estimation in time-of-flight list-mode positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Herraiz, J. L. [Madrid-MIT M+Visión Consortium, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 and Grupo de Física Nuclear, Departamento de Física Atómica, Molecular y Nuclear, Universidad Complutense de Madrid, CEI Moncloa, Madrid 28040 (Spain); Sitek, A., E-mail: sarkadiu@gmail.com [Center for Advanced Medical Imaging Sciences, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts 02114 (United States)

    2015-11-15

    Purpose: An accurate quantification of the images in positron emission tomography (PET) requires knowing the actual sensitivity at each voxel, which represents the probability that a positron emitted in that voxel is finally detected as a coincidence of two gamma rays in a pair of detectors in the PET scanner. This sensitivity depends on the characteristics of the acquisition, as it is affected by the attenuation of the annihilation gamma rays in the body, and possible variations of the sensitivity of the scanner detectors. In this work, the authors propose a new approach to handle time-of-flight (TOF) list-mode PET data, which allows performing either or both, a self-attenuation correction, and self-normalization correction based on emission data only. Methods: The authors derive the theory using a fully Bayesian statistical model of complete data. The authors perform an initial evaluation of algorithms derived from that theory and proposed in this work using numerical 2D list-mode simulations with different TOF resolutions and total number of detected coincidences. Effects of randoms and scatter are not simulated. Results: The authors found that proposed algorithms successfully correct for unknown attenuation and scanner normalization for simulated 2D list-mode TOF-PET data. Conclusions: A new method is presented that can be used for corrections for attenuation and normalization (sensitivity) using TOF list-mode data.

  7. 77 FR 8262 - Draft Guidance on Investigational New Drug Applications for Positron Emission Tomography Drugs...

    Science.gov (United States)

    2012-02-14

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2012-D-0081] Draft Guidance on Investigational New Drug Applications for Positron Emission Tomography Drugs; Availability AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food and Drug...

  8. Dynamic Positron Emission Tomography [PET] in Man Using Small Bismuth Germanate Crystals

    Science.gov (United States)

    Derenzo, S. E.; Budinger, T. F.; Huesman, R. H.; Cahoon, J. L.

    1982-04-01

    Primary considerations for the design of positron emission tomographs for medical studies in humans are the need for high imaging sensitivity, whole organ coverage, good spatial resolution, high maximum data rates, adequate spatial sampling with minimum mechanical motion, shielding against out of plane activity, pulse height discrimination against scattered photons, and timing discrimination against accidental coincidences. We discuss the choice of detectors, sampling motion, shielding, and electronics to meet these objectives.

  9. Radiation Therapy Oncology Group clinical trials with misonidazole

    International Nuclear Information System (INIS)

    Wasserman, T.H.; Stetz, J.; Phillips, T.L.

    1981-01-01

    This paper presents a review of the progressive clinical trials of the hypoxic cell radiosensitizer, misonidazole, in the Radiation Therapy Oncology Group (RTOG). Presentation is made of all the schemas of the recently completed and currently active RTOG Phase II and Phase III studies. Detailed information is provided on the clinical toxicity of the Phase II trials, specifically regarding neurotoxicity. With limitations in drug total dose, a variety of dose schedules have proven to be tolerable, with a moderate incidence of nausea and vomiting and mild peripheral neuropathy or central neuropathy. No other organ toxicity has been seen, specifically no liver, renal or bone marrow toxicities. An additional Phase III malignant glioma trial in the Brain Tumor Study Group is described

  10. Comparative assessment of 6-[18 F]fluoro-L-m-tyrosine and 6-[18 F]fluoro-L-dopa to evaluate dopaminergic presynaptic integrity in a Parkinson's disease rat model.

    Science.gov (United States)

    Becker, Guillaume; Bahri, Mohamed Ali; Michel, Anne; Hustadt, Fabian; Garraux, Gaëtan; Luxen, André; Lemaire, Christian; Plenevaux, Alain

    2017-05-01

    Because of the progressive loss of nigro-striatal dopaminergic terminals in Parkinson's disease (PD), in vivo quantitative imaging of dopamine (DA) containing neurons in animal models of PD is of critical importance in the preclinical evaluation of highly awaited disease-modifying therapies. Among existing methods, the high sensitivity of positron emission tomography (PET) is attractive to achieve that goal. The aim of this study was to perform a quantitative comparison of brain images obtained in 6-hydroxydopamine (6-OHDA) lesioned rats using two dopaminergic PET radiotracers, namely [ 18 F]fluoro-3,4-dihydroxyphenyl-L-alanine ([ 18 F]FDOPA) and 6-[ 18 F]fluoro-L-m-tyrosine ([ 18 F]FMT). Because the imaging signal is theoretically less contaminated by metabolites, we hypothesized that the latter would show stronger relationship with behavioural and post-mortem measures of striatal dopaminergic deficiency. We used a within-subject design to measure striatal [ 18 F]FMT and [ 18 F]FDOPA uptake in eight partially lesioned, eight fully lesioned and ten sham-treated rats. Animals were pretreated with an L-aromatic amino acid decarboxylase inhibitor. A catechol-O-methyl transferase inhibitor was also given before [ 18 F]FDOPA PET. Quantitative estimates of striatal uptake were computed using conventional graphical Patlak method. Striatal dopaminergic deficiencies were measured with apomorphine-induced rotations and post-mortem striatal DA content. We observed a strong relationship between [ 18 F]FMT and [ 18 F]FDOPA estimates of decreased uptake in the denervated striatum using the tissue-derived uptake rate constant K c . However, only [ 18 F]FMT K c succeeded to discriminate between the partial and the full 6-OHDA lesion and correlated well with the post-mortem striatal DA content. This study indicates that the [ 18 F]FMT could be more sensitive, with respect of [ 18 F]FDOPA, to investigate DA terminals loss in 6-OHDA rats, and open the way to in vivo L

  11. The effect of dexamethasone on the radiation survival response and misonidazole-induced hypoxic-cell cytotoxicity in Chinese hamster cells V-79-753B in vitro

    International Nuclear Information System (INIS)

    Millar, B.C.; Jinks, S.

    1981-01-01

    Overnight exposure of Chinese hamster cells, V-79-753B, to microgram quantities of the synthetic corticosteroid, dexamethasone, resulted in a decrease in sensitivity towards radiation, both in air and in hypoxia. The effect was dose-modifying and the oxygen enhancement ratio did not change appreciably. Similarly, when dexamethasone-treated hypoxic cells were irradiated in the presence of misonidazole, a hypoxic cell radiosensitizer, there was a decrease in radiation sensitivity compared with untreated hypoxic cells irradiated with misonidazole. (author)

  12. Deoxyfluoroketohexoses: 4-deoxy-4-fluoro-D-sorbose and -tagatose and 5-deoxy-5-fluoro-L-sorbose.

    Science.gov (United States)

    Rao, G V; Que, L; Hall, L D; Fondy, T P

    1975-04-01

    4-Deoxy-4-fluoro-alpha-D-sorbose (6) was prepared in crystalline form by the action of potassium hydrogen fluoride on 3,4-anhydro-1,2-O-isopropylidene-beta-D-psicopyranose (3) followed by deacetonation. Under identical conditions, 3,4-anhydro-1,2-O-isopropylidene-beta-D-tagatopyranose (7) underwent epoxide migration to give 4,5-anhydro-1,2-O-isopropylidene-beta-D-fructopyranose (12), which after deacetonation yielded 4-deoxy-4-fluoro-D-tagatose (15) and 5-deoxy-5-fluoro-alpha-L-sorbopyranose (16), the latter as the crystalline, free sugar. The action of glycol-cleavage reagents on the isopropylidene acetals of the deoxyfluoro sugars was consistent with the assigned structures. The structures were established by 13-C n.m.r. studies of the free deoxyfluoro sugars 6 and 16 and of the isopropylidene acetal 13, and by 1-H n.m.r. studies on the acetylated isopropylidene acetals 5 diacetate, 13 diacetate, and 14 diacetate. 5-Deoxy-5-fluoro-L-sorbose (16) was biologically active, producing in mice effects characteristic of deoxyfluorotrioses and of fluoroacetate. 4-Deoxy-4-fluoro-D-tagatose (15) and 4-deoxy-4-fluoro-D-sorbose (6) produced no apparent effects in mice up to a dose of 500mg/kg. The implications of these findings with respect to transport, phosphorylation, and the action of aldolase on ketohexoses are discussed.

  13. A new method of detection for a positron emission tomograph using a time of flight method

    International Nuclear Information System (INIS)

    Gresset, Christian.

    1981-05-01

    In the first chapter, it is shown the advantages of positron radioemitters (β + ) of low period, and the essential characteristics of positron tomographs realized at the present time. The second chapter presents the interest of an original technique of image reconstruction: the time of flight technique. The third chapter describes the characterization methods which were set for verifying the feasibility of cesium fluoride in tomography. Chapter four presents the results obtained by these methods. It appears that the cesium fluoride constitute presently the best positron emission associated to time of flight technique. The hypotheses made on eventual performances of such machines are validated by experiments with phantom. The results obtained with a detector (bismuth germanate) conserves all its interest in skull tomography [fr

  14. The role of positron emission tomography in the detection of incidental gastrointestinal tract lesions in patients examined for lung cancer

    International Nuclear Information System (INIS)

    Isobe, Kazutoshi; Hata, Yoshinobu; Sakaguchi, Shinji; Takai, Yujiro; Shibuya, Kazutoshi; Takagi, Keigo; Homma, Sakae

    2010-01-01

    The purpose of this study was to clarify the clinical characteristics of lung cancer patients with abnormal accumulation in the gastrointestinal tract by fluoro-2-deoxyglucose positron emission tomography (PET). Of the 968 consecutive patients with primary lung cancer who underwent PET from October 2005 through September 2009, 26 patients had local abnormal accumulation in the gastrointestinal tract. We retrospectively compared the localization of abnormal accumulation in the gastrointestinal tract, standardized uptake value (SUV)max (1 hour), and the final clinical diagnosis. The site of abnormal accumulation was the esophagus in 1 case, the stomach in 8 and the small intestine to large intestine in 17. In 15 out of 26 (57%) cases with true PET positive results, there was esophageal cancer in 1 case, gastric cancer in 2, gastrointestinal stromal tumor in 1, colon cancer in 8, and 1 each of metastasis to the stomach, small intestine and large intestine from lung cancer. In 11 cases with false PET-positive results, there was a stomach polyp in 1 case, gastritis in 3, colon polyp in 1, diverticulitis in 1 and normal physiologic accumulation in 5. There were no differences in mean SUVmax among malignant lesions, benign lesions, and normal physiologic accumulation. We should perform endoscopy of the digestive tract to detect malignant lesions with high incidence rates when PET shows localalized abnormal accumulation in the gastrointestinal, tract in patients with lung cancer. (author)

  15. Positron emission tomography and basal ganglia functions

    International Nuclear Information System (INIS)

    Kato, Motohiro; Otsuka, Makoto; Taniwaki, Koukyo; Hosokawa, Shinichi; Kuwabara, Yasuo; Ichiya, Yuichi

    1990-01-01

    With the advent of positron emission tomography (PET), studies on the human brain function and pathophysiology of brain damage have been extremely progressed. It is well-known that the basal ganglia plays an important role as one of the central nervous system involved in exercise regulation. More recently, the potential involvement of the basal ganglia in psychological processes, such as cognitive function, has been pointed out, receiving much attention. In spite of such a lot of studies, however, basal ganglia function remains unclear. This paper describes the relationships between PET findings and basal ganglia function. PET findings are discussed in relation to brain energy metabolism and striatal dopamine function. Pathophysiology of the basal ganglia are described in terms of the following diseases: Parkinson's disease, Parkinson's syndrome, progressive supranuclear palsy, Huntington's disease, and dystonia. Physiological backgrounds of the basal ganglia for PET images are also referred to. (N.K.) 75 refs

  16. Positron emission tomography and basal ganglia functions

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Motohiro; Otsuka, Makoto; Taniwaki, Koukyo; Hosokawa, Shinichi; Kuwabara, Yasuo; Ichiya, Yuichi [Kyushu Univ., Fukuoka (Japan). Faculty of Medicine

    1990-05-01

    With the advent of positron emission tomography (PET), studies on the human brain function and pathophysiology of brain damage have been extremely progressed. It is well-known that the basal ganglia plays an important role as one of the central nervous system involved in exercise regulation. More recently, the potential involvement of the basal ganglia in psychological processes, such as cognitive function, has been pointed out, receiving much attention. In spite of such a lot of studies, however, basal ganglia function remains unclear. This paper describes the relationships between PET findings and basal ganglia function. PET findings are discussed in relation to brain energy metabolism and striatal dopamine function. Pathophysiology of the basal ganglia are described in terms of the following diseases: Parkinson's disease, Parkinson's syndrome, progressive supranuclear palsy, Huntington's disease, and dystonia. Physiological backgrounds of the basal ganglia for PET images are also referred to. (N.K.) 75 refs.

  17. 2-[{sup 18}F]fluoro-2-deoxy-D-glucose positron emission tomography (F.D.G.-PET) can identify chronic lymphocytic leukaemia (C.L.L.) stage A et stage B patients; La tomographie par emission de positons au 2-[{sup 18}F] fluoro-2-desoxy-D-glucose (TEP-FDG) permet d'identifier les stades A et B des leucemies lymphoides chroniques (LLC)

    Energy Technology Data Exchange (ETDEWEB)

    Berthelot, C.; Vervueren, L.; Le Jeune, J.J.; Couturier, O. [Centre Hospitalier Universitaire, Service de Medecine Nucleaire, 49 - Angers (France); Truchan-Graczyk, M.; Genevieve, F.; Ifrah, N. [Centre Hospitalier Universitaire, Service d' Hematologie, 49 - Angers (France); Poirier, A.L. [BEC, centre Paul-Papin, 49 -Angers (France); Artur-Guillemette, P. [Centre Hospitalier Universitaire, Service de Radiologie, 49 - Angers (France)

    2009-09-15

    Purpose: There is no data in the literature concerning the utility of 2-[{sup 18}F]fluoro-2-deoxy-d-glucose positron emission tomography (F.D.G.-PET) in chronic lymphocytic leukaemia (C.L.L.), except for the diagnosis of Richter's transformations. The purpose of this study was to assess the potential role of F.D.G.-PET in C.L.L. stages A and B. Materials and methods Thirty-five patients (61 {+-} 9 years; 11 women, 24 men; 8 B and 27 A) have benefited of a F.D.G.-PET scan at baseline, for example, before an eventual treatment. F.D.G.-PET scans were analyzed visually and the maximum values of the Standardised Uptake Value (S.U.V.{sub max}) were measured in the main lymph nodes areas. The ability of F.D.G.-PET to differentiate stages A and B patients was evaluated by Student's tests and Receiver Operating Characteristics (R.O.C.) analysis. Results All patients with a normal F.D.G.-PET (n = 18) were stages A. The remaining 17 patients (9 A and 8 B) showed hyper metabolisms in nodal areas above (n = 17) and below (n = 9) the diaphragm, and no visceral involvement. The lymph nodes hyper metabolisms were always bilateral, and of low intensity (= mediastinum; 9 A), or of higher intensity (= liver, 8 B). The S.U.V.{sub max} of stage B (n = 8) were significantly higher than those of the 27 stages A, in all lymph nodes areas except in mediastinum. The highest intensity of F.D.G. uptake was observed in axillary area in stages B patients (S.U.V.max = 2.74 {+-} 1.03). An axillary S.U.V.{sub max} of 1.33 is the most suitable value for the discrimination between stages A and B patients (R.O.C.; AUC = 0.968; sensitivity 1.00; specificity 0.91). Conclusion Lymph nodes hyper metabolisms are constant in the B stage, and more intense than in stage A. These anomalies are always bilateral, unlike what is observed in Richter's transformation. The intensity of axillary lymph nodes F.D.G. uptake can distinguish C.L.L. stages A and B. (authors)

  18. Effect of combined misonidazole and accelerated neon ions on a human melanoma transplanted into nude mice

    International Nuclear Information System (INIS)

    Guichard, M.; Tenforde, T.; Curtis, S.; Malaise, E.P.

    1982-01-01

    The response to accelerated neon ions of human Nall melanomas growing in nude mice was measured by an in vitro colony-forming assay following in situ tumor irradiation in the midposition of a 10-cm extended-peak ionization region. Values of the relative biological effectiveness (RBE) for peak neon ions compared with 60 Coγ radiation were 3.2 and 3.4, respectively, at the 1% and 10% survival levels. Following irradiation with peak neon ions, the repair of potentially lethal damage (PLD) was comparable to that observed after γ irradiation. When misonidazole (1 mg/g intraperitoneal dose) was administered in combination with extended-peak neon ions, the drug enhancement ratio (ER) at the 1% survival level was 1.5 if the tumors were removed and plated in vitro immediately following irradiation, and 1.9 if tumor excision and plating were delayed for greater than or equal to 6 hours. Administration of misonidazole completely inhibited PLD repair following either γ irradiation or extended peak neon-ion irradiation

  19. Emission tomography with positrons principle, physical performances of a ring detector and quantitative possibilities

    International Nuclear Information System (INIS)

    Soussaline, F.; Plummer, D.; Todd Pokropek, A.E.; Loc'h, C.; Comar, D.

    1979-01-01

    Satisfactory qualitative and quantitative data in positron emission tomography requires the use of a well adapted tomographic system. A number of parameters have been identified which can be considered as the critical characteristics for evaluation and intercomparison of such systems. Using these the choice of a single slice ring positron camera could be justified by its physical performance, which is presented and discussed. Series of physical and mathematical simulations allow an appropriate knowledge of such a system, which has been in use for more than a year in a clinical environment. These studies aid to the interpretation of very interesting physiopathologic studies. In principle, a positron tomographic system permits measurement of absolute quantitative concentration values, which are essential for precise metabolic studies. The main sources of error comprising the calibration of the system, the tail effects and the precision for attenuation correction are analysed. When taking in account these errors, a precision of the order of 10% should be obtainable [fr

  20. Effectiveness of lead aprons in positron emission tomography

    International Nuclear Information System (INIS)

    Bezerra Fonseca, R.; Amaral, A.

    2008-01-01

    Full text: In the last two decades, Positron Emission Tomography (PET) has emerged as clinical diagnostic technique, becoming one of the fastest growing imaging tools in modern nuclear medicine. Because 511 keV annihilation photon energy is much higher than the photon with mean energy of 140 keV emitted in Single Photon Computed Tomography (SPECT), medical staff working in PET studies receive a higher dose than those working only with SPECT tracers do. As a result, special attention must be paid to keep radiation exposure as low as reasonably achievable (ALARA principle). Lead equivalent apron is the principal personal protective equipment for technologists occupationally exposed to ionizing radiation in medical procedures and may be an important component in the ALARA program. However, in practices involving PET, 0.5 mm lead equivalent aprons have been used regardless of photon's energy. In this context, this work was designed for evaluating radioprotective effectiveness of such aprons in PET procedures. For this, the operational quantities personal dose equivalent H p (0.07) and H p (10) have been assessed by using MCNP4C code in a model of individual exposure to small source of 511 keV photons, representing the situation of injection of the radiopharmaceutical, in two situations: technologists wearing and not wearing 0.5 mm lead aprons. To represent the technologist a mathematical anthropomorphic phantom was employed, and the simulated source to subject distances varied between 40 to 100 cm, in steps of 10 cm. The results showed no significant differences between the values obtained for H p (10) in the two situations, pointing out that that there is no radioprotective influence of wearing such aprons on PET practices. Compared to simulations without such device, H p (0.07) increased up about 26% when technologist is wearing radioprotective aprons, depending on the source to subject distance. On the basis of this work, 0.5 mm lead equivalent aprons should not be