WorldWideScience

Sample records for fluorescence spectrometer innovative

  1. Portable x-ray fluorescence spectrometer. Innovative technology summary report

    International Nuclear Information System (INIS)

    1998-12-01

    This report describes the application of portable X-ray fluorescence (XRF) spectrometry to characterize materials related to deactivation and decommissioning (D and D) of contaminated facilities. Two portable XRF instruments manufactured by TN Spectrace were used in a technology evaluation as part of the Large-Scale Demonstration Project (LSDP) held at the Chicago Pile-5 Research Reactor (CP-5) located at Argonne National Laboratory (ANL). The LSDP is sponsored by the US Department of Energy (DOE), Office of Science and Technology, Deactivation and Decommissioning Focus Are (DDFA). The objective of the LSDP is to demonstrate innovative technologies or technology applications potentially beneficial to the D and D of contaminated facilities. The portable XRF technology offers several potential benefits for rapid characterization of facility components and contaminants, including significant cost reduction, fast turnaround time,a nd virtually no secondary waste. Field work for the demonstration of the portable XRF technology was performed from August 28--September 3, 1996 and October 30--December 13, 1996

  2. Remote UV Fluorescence Lifetime Spectrometer, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal of this project is to develop, demonstrate, and deliver to NASA an innovative, portable, and power efficient Remote UV Fluorescence Lifetime Spectrometer...

  3. Experimental study on microlaser fluorescence spectrometer

    Science.gov (United States)

    Tian, Zhaoshuo; Wang, Ling; Zhang, Shanshan; Zhang, Yanchao; Liu, Libao; Gu, Erdan

    2018-01-01

    This paper presents a kind of miniature handheld laser fluorescence spectrometer, which integrates a laser emission system, a spectroscopic system, and a detection system into a volume of 100×50×20 mm3. A universal serial bus interface is connected to PC for data processing and spectrum display. The emitted laser wavelength is 405 nm. A spectral range is 400 to 760 nm and 2-nm optical resolution has been achieved. This spectrometer has the advantages of compact structure, small volume, high sensitivity, and low cost.

  4. Innovative instrumentation for mineralogical and elemental analyses of solid extraterrestrial surfaces: The Backscatter Moessbauer Spectrometer/X Ray Fluorescence analyzer (BaMS/XRF)

    Science.gov (United States)

    Shelfer, T. D.; Morris, Richard V.; Nguyen, T.; Agresti, D. G.; Wills, E. L.

    1994-01-01

    We have developed a four-detector research-grade backscatter Moessbauer spectrometer (BaMS) instrument with low resolution x-ray fluorescence analysis (XRF) capability. A flight-qualified instrument based on this design would be suitable for use on missions to the surfaces of solid solar-system objects (Moon, Mars, asteroids, etc.). Target specifications for the flight instrument are as follows: mass less than 500 g; volumes less than 300 cu cm; and power less than 2 W. The BaMS/XRF instrument would provide data on the oxidation state of iron and its distribution among iron-bearing mineralogies and elemental composition information. This data is a primary concern for the characterization of extraterrestrial surface materials.

  5. Combined "dual" absorption and fluorescence smartphone spectrometers.

    Science.gov (United States)

    Arafat Hossain, Md; Canning, John; Ast, Sandra; Cook, Kevin; Rutledge, Peter J; Jamalipour, Abbas

    2015-04-15

    A combined "dual" absorption and fluorescence smartphone spectrometer is demonstrated. The optical sources used in the system are the white flash LED of the smartphone and an orthogonally positioned and interchangeable UV (λex=370  nm) and blue (λex=450  nm) LED. The dispersive element is a low-cost, nano-imprinted diffraction grating coated with Au. Detection over a 300 nm span with 0.42 nm/pixel resolution was carried out with the camera CMOS chip. By integrating the blue and UV excitation sources into the white LED circuitry, the entire system is self-contained within a 3D printed case and powered from the smartphone battery; the design can be scaled to add further excitation sources. Using a customized app, acquisition of absorption and fluorescence spectra are demonstrated using a blue-absorbing and green-emitting pH-sensitive amino-naphthalimide-based fluorescent probe and a UV-absorbing and blue-emitting Zn2+-sensitive fluoro-ionophore.

  6. [Development of X-ray excited fluorescence spectrometer].

    Science.gov (United States)

    Ni, Chen; Gu, Mu; Di, Wang; Cao, Dun-Hua; Liu, Xiao-Lin; Huang, Shi-Ming

    2009-08-01

    An X-ray excited fluorescence spectrometer was developed with an X-ray tube and a spectrometer. The X-ray tube, spectrometer, autocontrol method and data processing selected were roundly evaluated. The wavelength and detecting efficiency of the apparatus were calibrated with the mercury and tungsten bromine standard lamps, and the X-ray excited emission spectra of BaF2, Cs I (Tl) crystals were measured. The results indicate that the apparatus has advantages of good wavelength resolution, high stability, easy to operation and good radioprotection. It is a wery effective tool for exploration of new scintillation materials.

  7. Developing an imaging bi-spectrometer for fluorescent materials

    Science.gov (United States)

    Mohammadi, Mahnaz

    Fluorescent effects have been observed for thousands of years. Stokes, in 1852, began the science of fluorescence culminating in his law of fluorescence, which explained that fluorescence emission occurs at longer wavelengths than the excitation wavelength. This phenomenon is observed extensively in the art world. Daylight fluorescent colors known as Day-GloRTM have become an artistic medium since the 1960s. Modern artists exploit these saturated and brilliant colors to glitter their painting. Multipsectral imaging as a noninvasive technique has been used for archiving by museums and cultural-heritage institutions for about a decade. The complex fluorescence phenomenon has been often ignored in the multispectral projects. The ignored fluorescence results in errors in digital imaging of artwork containing fluorescent colors. The illuminant-dependency of the fluorescence radiance makes the fluorescence colorimetry and consequently spectral imaging more complex. In this dissertation an abridged imaging bi-spectrometer for artwork containing both fluorescent and non-fluorescent colors was developed. The method developed included two stages of reconstruction of the spectral reflected radiance factor and prediction of the fluorescent radiance factor. The estimation of the reflected radiance factor as a light source independent component was achieved by imaging with a series of short-wavelength cutoff filters placed in the illumination path. The fluorescent radiance factor, a light source dependent component, was estimated based on a proposed model, the abridged two-monochromator method. The abridged two-monochromator method was developed for reconstructing the bi-spectral matrix of a fluorescent color based on a calibrated UV-fluorescence imaging. In this way, one could predict the fluorescence radiance factor under any desired illuminant and consequently a better color evaluation and rendering could be obtained. Furthermore, this method easily fitted in a general system

  8. Elemental analysis using a handheld X-Ray fluorescence spectrometer

    Science.gov (United States)

    Groover, Krishangi D.; Izbicki, John

    2016-06-24

    The U.S. Geological Survey is collecting geologic samples from local stream channels, aquifer materials, and rock outcrops for studies of trace elements in the Mojave Desert, southern California. These samples are collected because geologic materials can release a variety of elements to the environment when exposed to water. The samples are to be analyzed with a handheld X-ray fluorescence (XRF) spectrometer to determine the concentrations of up to 27 elements, including chromium.

  9. [The X-Ray Fluorescence Spectrometer Based on Pyroelectric Effect].

    Science.gov (United States)

    Dong, Yi-fan; Fan, Rui-rui; Guo, Dong-ya; Zhang, Chun-lei; Gao, Min; Wang, Jin-zhou; Liu, Ya-qing; Zhou, Da-wei; Wang, Huan-yu

    2016-02-01

    Pyroelectric X-ray generator is implemented, and an X-ray fluorescence spectrometer is accomplished by combining the pyroelectric X-ray generator with a high energy resolution silicon drift detector. Firstly, the parameters of the X-ray generator are decided by analyzing and calculating the influence of the thickness of the pyroelectriccrystal and the thickness of the target on emitted X-ray. Secondly, the emitted X-ray is measured. The energy of emitted X-ray is from 1 to 27 keV, containing the characteristic X-ray of Cu and Ta, and the max counting rate is more than 3 000 per second. The measurement also proves that the detector of the spectrometer has a high energy resolution which the FWMH is 210 eV at 8. 05 keV. Lastly, samples of Fe, Ti, Cr and high-Ti basalt are analyzed using the spectrometer, and the results are agreed with the elements of the samples. It shows that the spectrometer consisting of a pyroelectric X-ray generator and a silicon drift detector is effective for element analysis. Additionally, because each part of the spectrometer has a small volume, it can be easily modified to a portable one which is suitable for non-destructive, on-site and quick element analysis.

  10. Fast Monitoring Soil Environmental Qualities of Heavy Metal by Portable X-Ray Fluorescence Spectrometer.

    Science.gov (United States)

    Wang, Bao; Yu, Jian-xin; Huang, Biao; Hu, Wen-you; Chang, Qing

    2015-06-01

    Portable X-ray fluorescence (PXRF) spectrometer as a new type of equipment for quick test has a prominent prospect, but there are also shortcomings of detection range and limition, therefore this paper studied the suitability of PXRF spectrometer in monitoring soil environmental qualities of heavy metals included Cr, Ni, Cu, Zn, Pb, Cd, As and Hg, the aim of this paper is to screen elements which can be detected by this kind of instrument and evaluate the accuracy of test results. The research method is to test heavy metals contaminated soil samples by PXRF spectrometer, evaluate the accuracy of test results of PXRF compared with inductively coupled plasma mass(ICP-MS), then establish linear regression relationship between analysis results of PXRF and ICP-MS method. The results show that, (1) When measuring the soil environmental quality, PXRF spectrometer is appropriate to measure the content of Pb, Zn, Cr and Cu, except Ni, Cd, As and Hg. (2) Compared with the test value of ICP-MS, the test value of Pb and Zn is lower, the test value of Cu is higher, the test value of Cr is too high, all the results of PXRF spectrometer should be linear corrected according to standard analysis method. In conclusion, PXRF spectrometer is suitable for monitoring environmental quality of soil which is polluted by heavy metal such as Pb, Zn, Cr and Cu, it is an analysis means with characteristics of simple and rapid, accurate and reliable. The innovation of this article is that reasonable avoiding the shortcomings of PXRF spectrometer as using the instrument to monitor soil environmental quality, at last improved the application value of test results.

  11. FLEX: an imaging spectrometer for measurement of vegetation fluorescence

    Science.gov (United States)

    Smorenburg, Kees; Visser, Huib; Court, Andrew; Stoll, Marc Ph.

    2017-11-01

    Detection of vegetation fluorescence gives information about plant functioning, stress and vitality. During the past decades several ground based laser fluorosensors have been developed to investigate these processes and to demonstrate the value of this technique. FLEX (= FLuorescense EXplorer) is a space mission to measure the fluorescence of vegetation on earth over large areas from space. Such a mission would greatly improve the understanding and enhance the capability to quantify e.g. the role of terrestrial vegetation in global carbon sequestration. Because the fluorescence signal, which is excited by solar irradiation is low with respect to the reflected sunlight the signal from a satellite is proposed to be measured in the solar Fraunhofer lines, where the reflection signal is much reduced. The heart of FLEX is a high resolution imaging spectrometer with 2 channels: channel 1 around the Fraunhofer lines at ‡ = 397 nm, ‡= 423 nm and/or ‡ = 434 nm and channel 2 around the Fraunhofer line at ‡ = 656 nm. The required spectral resolution will depend on the linewidth (0.02-0.3 nm). A first definition of the field of view is 8.4 degrees, leading from an 800 km satellite altitude to a swath of about 120 km. For detection a 1024x1024 pixel frame transfer CCD detector is proposed, with a pixel dimension of 13 x 13 ‡ mm2. The maximum footprint is about 500x500m2. The optical configuration contains a scan mirror for solar calibration, for pointing the FOV in swath direction and for freezing the observed ground scene up to a few seconds to increase the signal to noise performance. At this moment the concept of FLEX is elaborated in a feasibility study. Both the scientific and instrument requirements are updated and the concept is studied in detail. Besides a development plan for FLEX is made. In this paper the idea and the headlines of FLEX are described.

  12. Hyper-filter-fluorescer spectrometer for fusion x-ray diagnostics

    International Nuclear Information System (INIS)

    Wang, C.L.

    1981-01-01

    The filter-fluorescer spectrometer (FFS) is a powerful tool for measuring x-ray spectrum from high fluence x-ray sources. However, this technique is limited to energies less than 120 keV, because there are no practical absorption edges available above this energy. In this paper, we present a new method of utilizing the filter-fluorescer system for x-ray spectral measurement above 120 keV. The new apparatus is called hyper-filter-fluorescer spectrometer

  13. The Mapping X-ray Fluorescence Spectrometer (MapX)

    Science.gov (United States)

    Sarrazin, P.; Blake, D. F.; Marchis, F.; Bristow, T.; Thompson, K.

    2017-12-01

    Many planetary surface processes leave traces of their actions as features in the size range 10s to 100s of microns. The Mapping X-ray Fluorescence Spectrometer (MapX) will provide elemental imaging at 100 micron spatial resolution, yielding elemental chemistry at a scale where many relict physical, chemical, or biological features can be imaged and interpreted in ancient rocks on planetary bodies and planetesimals. MapX is an arm-based instrument positioned on a rock or regolith with touch sensors. During an analysis, an X-ray source (tube or radioisotope) bombards the sample with X-rays or alpha-particles / gamma-rays, resulting in sample X-ray Fluorescence (XRF). X-rays emitted in the direction of an X-ray sensitive CCD imager pass through a 1:1 focusing lens (X-ray micro-pore Optic (MPO)) that projects a spatially resolved image of the X-rays onto the CCD. The CCD is operated in single photon counting mode so that the energies and positions of individual X-ray photons are recorded. In a single analysis, several thousand frames are both stored and processed in real-time. Higher level data products include single-element maps with a lateral spatial resolution of 100 microns and quantitative XRF spectra from ground- or instrument- selected Regions of Interest (ROI). XRF spectra from ROI are compared with known rock and mineral compositions to extrapolate the data to rock types and putative mineralogies. When applied to airless bodies and implemented with an appropriate radioisotope source for alpha-particle excitation, MapX will be able to analyze biogenic elements C, N, O, P, S, in addition to the cations of the rock-forming elements >Na, accessible with either X-ray or gamma-ray excitation. The MapX concept has been demonstrated with a series of lab-based prototypes and is currently under refinement and TRL maturation.

  14. A Compact Fluorescence Lifetime Excitation-Emission Spectrometer (FLEXEMS) for Detecting Trace Organics, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Small Business Innovative Research (SBIR) effort, Leiden Measurement Technology (LMT) proposes to design and build the Fluorescence Lifetime Excitation...

  15. A Compact Fluorescence Lifetime Excitation-Emission Spectrometer (FLEXEMS) for Detecting Trace Organics, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Small Business Innovative Research (SBIR) effort, Leiden Measurement Technology (LMT) proposes to design and build the Fluorescence Lifetime Excitation...

  16. Field transportable beta spectrometer. Innovative technology summary report

    International Nuclear Information System (INIS)

    1998-12-01

    The objective of the Large-Scale Demonstration Project (LSDP) is to select and demonstrate potentially beneficial technologies at the Argonne National Laboratory-East (ANL) Chicago Pile-5 Test Reactor (CP-5). The purpose of the LSDP is to demonstrate that by using innovative and improved deactivation and decommissioning (D and D) technologies from various sources, significant benefits can be achieved when compared to baseline D and D technologies. One such capability being addressed by the D and D Focus Area is rapid characterization for facility contaminants. The technology was field demonstrated during the period January 7 through January 9, 1997, and offers several potential benefits, including faster turn-around time, cost reduction, and reduction in secondary waste. This report describes a PC controlled, field-transportable beta counter-spectrometer which uses solid scintillation coincident counting and low-noise photomultiplier tubes to count element-selective filters and other solid media. The dry scintillation counter used in combination with an element-selective technology eliminates the mess and disposal costs of liquid scintillation cocktails. Software in the instrument provides real-time spectral analysis. The instrument can detect and measure Tc-99, Sr-90, and other beta emitters reaching detection limits in the 20 pCi range (with shielding). Full analysis can be achieved in 30 minutes. The potential advantages of a field-portable beta counter-spectrometer include the savings gained from field generated results. The basis for decision-making is provided with a rapid turnaround analysis in the field. This technology would be competitive with the radiometric analysis done in fixed laboratories and the associated chain of custody operations

  17. Micro-X-ray fluorescence spectrometer with x-ray single bounce metallic capillary optics for light element analysis (Conference Presentation)

    Science.gov (United States)

    Mroczka, Robert; Żukociński, Grzegorz; Łopucki, Rafał

    2017-05-01

    In the last 20 years, , due to the rapid development of X-ray optics, micro X-ray fluorescence spectrometry (micro-XRF) has become a powerful tool to determine the spatial distribution of major, minor, and trace elements within a sample. Micro-X-ray fluorescence (micro-XRF) spectrometers for light element analysis (6 work was supported and co-funded by the European Union as part of the Operational Programme Development of Eastern Poland for 2007-2013, Priority I Innovative Economy, Measure I.3. Support for Innovations and The National Centre for Research and Development, Project no. TANGO1,267102/NCBR/2015

  18. Innovative design and fabrication of safety enclosure for WD-XRF spectrometer

    International Nuclear Information System (INIS)

    Anwar, M.K.; Khan, A.M.; Bangash, M.A.

    2011-01-01

    A wavelength dispersive X-ray fluorescence spectrometer, Pan Analytical (Philips) model. Magix was purchased in 2002 for chemical analysis of nuclear related materials. The required analytical work could not be done in open atmosphere due to active nature of the samples. The Glove box adapted models of these instruments are banned for our country. Therefore modification and Glove box (GB) adaptation was required. It was very innovative and time consuming assignment as only sample handling part of the instrument had to be placed inside GB, leaving rest of the instrument available for later repair/maintenance work. Different options were considered for adaptation point of view, keeping in mind the isolation and negative pressure inside the GB. One of such option was finalized which involved placing a tray in between the spectrometer and top shield plate. An intricate and complex geometrical shaped tray was designed which extended outward in the shape of a glove box. In this way originality of the instrument was maintained as well as the required objectives were achieved. (author)

  19. Fluorescence from atmospheric aerosols observed with a multi-channel lidar spectrometer.

    Science.gov (United States)

    Sugimoto, Nobuo; Huang, Zhongwei; Nishizawa, Tomoaki; Matsui, Ichiro; Tatarov, Boyan

    2012-09-10

    A lidar for measuring fluorescence from atmospheric aerosols was constructed with a third harmonic Nd:YAG laser, a 1-m diameter telescope, and a 32-channel time-resolved photon-counting spectrometer system. Fluorescence spectrum and vertical distribution of fluorescent aerosols in the lower atmosphere were observed during the nighttime with excitation at 355 nm. Relatively strong broad fluorescence was observed from Asian dust and air-pollution aerosols transported from urban and industrial areas. Rough estimates of the fluorescence efficiency were given for these aerosols. The intensity of the total fluorescence over the spectral range from 420 to 510 nm was comparable to that of nitrogen vibrational Raman scattering. That indicates the possibility of making a compact Raman-Mie-fluorescence lidar for aerosol monitoring.

  20. Portable total reflection X-ray fluorescence spectrometer for nanogram Cr detection limit.

    Science.gov (United States)

    Kunimura, Shinsuke; Kawai, Jun

    2007-03-15

    A portable total reflection X-ray fluorescence spectrometer is presented. The present spectrometer mainly consists of a 1.5-W X-ray tube, a waveguide type slit, a detector, and a sample carrier (a quartz optical flat), and these components are contained in an attache case-type box. Continuum X-rays emitted from the low-power X-ray tube are used for the excitation of the X-ray fluorescence, and the minimum detection limit for Cr is a few nanograms or the level of 1013 atoms/cm2.

  1. A Fundamental Parameter-Based Calibration Model for an Intrinsic Germanium X-Ray Fluorescence Spectrometer

    DEFF Research Database (Denmark)

    Christensen, Leif Højslet; Pind, Niels

    1982-01-01

    A matrix-independent fundamental parameter-based calibration model for an energy-dispersive X-ray fluorescence spectrometer has been developed. This model, which is part of a fundamental parameter approach quantification method, accounts for both the excitation and detection probability. For each...

  2. The Mapping X-Ray Fluorescence Spectrometer (MAPX)

    Science.gov (United States)

    Blake, David; Sarrazin, Philippe; Bristow, Thomas; Downs, Robert; Gailhanou, Marc; Marchis, Franck; Ming, Douglas; Morris, Richard; Sole, Vincente Armando; Thompson, Kathleen; hide

    2016-01-01

    MapX will provide elemental imaging at =100 micron spatial resolution over 2.5 X 2.5 centimeter areas, yielding elemental chemistry at or below the scale length where many relict physical, chemical, and biological features can be imaged and interpreted in ancient rocks. MapX is a full-frame spectroscopic imager positioned on soil or regolith with touch sensors. During an analysis, an X-ray source (tube or radioisotope) bombards the sample surface with X-rays or alpha-particles / gamma rays, resulting in sample X-ray Fluorescence (XRF). Fluoresced X-rays pass through an X-ray lens (X-ray µ-Pore Optic, "MPO") that projects a spatially resolved image of the X-rays onto a CCD. The CCD is operated in single photon counting mode so that the positions and energies of individual photons are retained. In a single analysis, several thousand frames are stored and processed. A MapX experiment provides elemental maps having a spatial resolution of =100 micron and quantitative XRF spectra from Regions of Interest (ROI) 2 centimers = x = 100 micron. ROI are compared with known rock and mineral compositions to extrapolate the data to rock types and putative mineralogies. The MapX geometry is being refined with ray-tracing simulations and with synchrotron experiments at SLAC. Source requirements are being determined through Monte Carlo modeling and experiment using XMIMSIM [1], GEANT4 [2] and PyMca [3] and a dedicated XRF test fixture. A flow-down of requirements for both tube and radioisotope sources is being developed from these experiments. In addition to Mars lander and rover missions, MapX could be used for landed science on other airless bodies (Phobos/Deimos, Comet nucleus, asteroids, the Earth's moon, and the icy satellites of the outer planets, including Europa.

  3. Fluorescence Behavior and Dural Infiltration of Meningioma Analyzed by 5-Aminolevulinic Acid-Based Fluorescence: Operating Microscope Versus Mini-Spectrometer.

    Science.gov (United States)

    Knipps, Johannes; Beseoglu, Kerim; Kamp, Marcel; Fischer, Igor; Felsberg, Joerg; Neumann, Lisa M; Steiger, Hans-Jakob; Cornelius, Jan F

    2017-12-01

    To compare fluorescence intensity of tumor specimens, as measured by a fluorescence-guided surgery microscope and a spectrometer, to evaluate tumor infiltration of dura mater around meningiomas with help of these 2 different 5-aminolevulinic acid (5-ALA)-based fluorescence tools, and to correlate fluorescence intensity with histopathologic data. In a clinical series, meningiomas were resected by 5-ALA fluorescence-guided surgery. Fluorescence intensity was semiquantitatively rated by the surgeon at predefined points. Biopsies were harvested and fluorescence intensity measured by a spectrometer and histopathologically analyzed. Sampling was realized at the level of the dura in a centrifugal direction. A total of 104 biopsies (n = 13 tumors) were analyzed. Specificity and sensitivity of the microscope were 0.96 and 0.53 and of the spectrometer 0.95 and 0.93, respectively. Fluorescence intensity as measured by the spectrometer was correlated to histologically confirmed tumor burden. In a centrifugal direction, tumor burden and fluorescence intensity continuously decreased (along the dural tail). Below a threshold value of 639 arbitrary units no tumor was histologically detectable. At the level of the dura the spectrometer was highly sensitive for detection of meningioma cells. The surgical microscope showed false negative results and missed residual tumor cells in more than one half of the cases. The complementary use of both fluorescence tools may improve resection quality. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. A high resolution x-ray fluorescence spectrometer for near edge absorption studies

    International Nuclear Information System (INIS)

    Stojanoff, V.; Hamalainen, K.; Siddons, D.P.; Hastings, J.B.; Berman, L.E.; Cramer, S.; Smith, G.

    1991-01-01

    A high resolution fluorescence spectrometer using a Johann geometry in a back scattering arrangement was developed. The spectrometer, with a resolution of 0.3 eV at 6.5 keV, combined with an incident beam, with a resolution of 0.7 eV, form the basis of a high resolution instrument for measuring x-ray absorption spectra. The advantages of the instrument are illustrated with the near edge absorption spectrum of dysprosium nitrate. 10 refs., 4 figs

  5. A new design approach to innovative spectrometers. Case study: TROPOLITE

    Science.gov (United States)

    Volatier, Jean-Baptiste; Baümer, Stefan; Kruizinga, Bob; Vink, Rob

    2014-05-01

    Designing a novel optical system is a nested iterative process. The optimization loop, from a starting point to final system is already mostly automated. However this loop is part of a wider loop which is not. This wider loop starts with an optical specification and ends with a manufacturability assessment. When designing a new spectrometer with emphasis on weight and cost, numerous iterations between the optical- and mechanical designer are inevitable. The optical designer must then be able to reliably produce optical designs based on new input gained from multidisciplinary studies. This paper presents a procedure that can automatically generate new starting points based on any kind of input or new constraint that might arise. These starting points can then be handed over to a generic optimization routine to make the design tasks extremely efficient. The optical designer job is then not to design optical systems, but to meta-design a procedure that produces optical systems paving the way for system level optimization. We present here this procedure and its application to the design of TROPOLITE a lightweight push broom imaging spectrometer.

  6. Portable X-ray fluorescence spectrometer. Radiation hazard during utilization; Tragbare Roentgenfluoreszenzspektrometer. Strahlungsgefaehrdung bei der Verwendung

    Energy Technology Data Exchange (ETDEWEB)

    Spiess, Lothar

    2015-07-01

    The question in relation to radiation hazards of a portable X-ray fluorescence spectrometer is: In which time and for which instrument the hand dose is surmounted according radiation protection recommendations? The contribution shows the complexity of radiation protection. In each case of application the user should always be aware which dose leaves the equipment and how this radiation is absorbed. This is the only way of comparison with the legal dose limits.

  7. Development of a compact grazing exit X-ray fluorescence spectrometer for fast trace elemental analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ashida, Takafumi, E-mail: ashidatakafumi@gmail.com; Tsuji, Kouichi

    2014-11-01

    A compact grazing exit X-ray fluorescence (GE-XRF) spectrometer was developed in the laboratory. An Al cylindrical collimator for the primary X-rays was placed just above the sample stage. This collimator also played the role of an exit slit to detect fluorescent X-rays at small grazing exit angles. Therefore, no additional exit slit was used in this setup, leading to a compact design. The entire size of the analysis equipment was 80 mm × 200 mm × 170 mm (horizontal × vertical × height). The maximum exit angle was adjusted to the height of the sample stage. The background was drastically reduced at grazing exit angles, enabling trace elemental analysis. A calibration curve was obtained using 10 μL Ga solutions. Accordingly, the detection limit for Ga was evaluated to be 20 ppb. - Highlights: • We developed a compact GE-XRF spectrometer. • The dimension of GE-XRF spectrometer was 80 mm × 200 mm × 170 mm. • A detection limit of 20 ppb for Ga was obtained. • Analytical performance was comparable with that of a table-top TXRF spectrometer.

  8. Progress Toward Innovations in Cryogenic Ion Cluster Spectrometers

    Science.gov (United States)

    Howdieshell, Casey J.; Garand, Etienne

    2017-06-01

    Cryogenic Ion Vibrational Spectroscopy (CIVS) is a useful technique that yields rich information about non-covalent interactions in various systems including catalytic complexes, small biologically relevant molecules, and solvent networks. Current instrumentation demands high production costs and large laboratory facilities. We have designed an affordable and compact instrument that is capable of current CIVS experiments. This setup utilizes an ion funnel and a Linear Trap Quadrupole (LTQ) which improves the ion density and allows for spectroscopic interrogation directly in the trap. Preliminary results and future innovations will be discussed.

  9. Chemical Characterization of Nuclear Materials: Development a New Combined X-Ray Fluorescence and Raman Spectrometer

    International Nuclear Information System (INIS)

    Szaloki, I.; Gerenyi, A.

    2015-01-01

    New mobile analytical device based on combination of X-ray fluorescence and Raman spectrometer has been developed for prompt and quantitative characterization of chemical component from Al to U in nuclear waste or undeclared materials. The excitation source of the X-ray fluorescence spectrometer is an air-cooled X-ray tube with Ag transmission anode. For collection of secondary X-ray photons and data processing, a compact Amptek X-ray detector system is applied with silicon drift X-ray detector. The XRF system operates in confocal mode with focal volume around 1-4 mm 3 . Varying the geometrical position and orientation of the sample optional part of its surface can be analyzed. The Raman unit includes thermoelectrically cooled laser source having 500 mW power at wavelength 785 nm. In order to obtain spectral information from sample surface a reflection-type probe is connected by optical fibres to the Raman spectrometer. A mini focusing optics is set up to the sensor-fibre that provides the system to operate as confocal optical device in reflection mode. The XRF spectrometer with X-ray detector, Raman probe and X-ray tube are mechanically fixed and hermetically connected to an aluminium chamber, which can be optionally filled with helium. The chamber is mounted on a vertical stage that provides moving it to the sample surface. A new model and computer code have been developed for XRF quantitative analysis which describes the mathematical relationship between the concentration of sample elements and their characteristic X-ray intensities. For verification of the calculations standard reference alloy samples were measured. The results was in good agreement with certified concentrations in range of 0.001-100 w%. According to these numerical results this new method is successfully applicable for quick and non-destructive quantitative analysis of waste materials without using standard samples. (author)

  10. Exploratory analysis for the identification of false banknotes using portable X-ray Fluorescence spectrometer.

    Science.gov (United States)

    Zamalloa Jara, M A; Luízar Obregón, C; Araujo Del Castillo, C

    2018-05-01

    The aim of this study was to verify if a portable X-ray fluorescence (pXRF) spectrometer can recognize the security features in banknotes that are reproducible by counterfeiters. Peruvian Nuevo Sol banknotes were studied: 4 genuine and 3 fake ones, in 11 points of analysis for each one, at all 77 data set. The correlation analysis of spectra among original notes was 1.0, and there was no correlation with fake banknotes. pXRF prove that two security features were reproducible for counterfeiters. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  11. Note: Portable total reflection X-ray fluorescence spectrometer with small vacuum chamber

    Science.gov (United States)

    Kunimura, Shinsuke; Kudo, Shunpei; Nagai, Hiroki; Nakajima, Yoshihide; Ohmori, Hitoshi

    2013-04-01

    To improve the detection limits of a portable total reflection X-ray fluorescence (TXRF) spectrometer using white X-rays (i.e., both characteristic X-rays and continuum X-rays) from a 5 W X-ray tube, the measurement was performed in vacuum. The TXRF spectrum measured in vacuum was compared with that measured in air. The spectral background was significantly reduced when the scattering of the incident X-rays from air was reduced using a vacuum pump, leading to improvement in the detection limit. A detection limit of 8 pg was achieved for Cr when measuring in vacuum.

  12. Note: Portable total reflection X-ray fluorescence spectrometer with small vacuum chamber.

    Science.gov (United States)

    Kunimura, Shinsuke; Kudo, Shunpei; Nagai, Hiroki; Nakajima, Yoshihide; Ohmori, Hitoshi

    2013-04-01

    To improve the detection limits of a portable total reflection X-ray fluorescence (TXRF) spectrometer using white X-rays (i.e., both characteristic X-rays and continuum X-rays) from a 5 W X-ray tube, the measurement was performed in vacuum. The TXRF spectrum measured in vacuum was compared with that measured in air. The spectral background was significantly reduced when the scattering of the incident X-rays from air was reduced using a vacuum pump, leading to improvement in the detection limit. A detection limit of 8 pg was achieved for Cr when measuring in vacuum.

  13. Ultraminiature X-ray fluorescence spectrometer for in-situ geochemical analysis on Mars.

    Science.gov (United States)

    Clark, B. C.; Baird, A. K.

    1973-01-01

    A spectrometer based upon the X-ray fluorescence method of elemental analysis has been developed in an ultraminiature, rugged form suitable for a spacecraft mission to Mars. The instrument employs two radioisotope sources (Fe-55 and Cd-109) which irradiate adjacent areas on a regolith sample. Fluorescent X rays emitted by the sample are detected by four thin-window proportional counters. Using pulse-height discrimination, the energy spectra are determined. Virtually all elements above sodium in the periodic table are detected if present at sufficient levels. Minimum detection limits range from 30 ppm to 2% depending upon the element and the matrix. For most elements, they are below 0.5%. Accuracies also depend upon the matrix, but are generally better than plus or minus 0.5% for all elements of atomic number greater than 14. Elements below sodium are also detected, but as a single group. Ambiguities of identification of the elements producing the observed spectra are minimal.

  14. Vertical profiles of atmospheric fluorescent aerosols observed by a mutil-channel lidar spectrometer system

    Science.gov (United States)

    Huang, Z.; Huang, J.; Zhou, T.; Sugimoto, N.; Bi, J.

    2015-12-01

    Zhongwei Huang1*, Jianping Huang1, Tian Zhou1, Nobuo Sugimoto2, Jianrong Bi1 and Jinsen Shi11Key Laboratory for Semi-Arid Climate Change of the Ministry of Education, College of Atmospheric Sciences, Lanzhou University, Lanzhou, China. 2Atmospheric Environment Division, National Institutes for Environmental Studies, Tsukuba, Japan Email: huangzhongwei@lzu.edu.cn Abstract Atmospheric aerosols have a significant impact on regional and globe climate. The challenge in quantifying aerosol direct radiative forcing and aerosol-cloud interactions arises from large spatial and temporal heterogeneity of aerosol concentrations, compositions, sizes, shape and optical properties (IPCC, 2007). Lidar offers some remarkable advantages for determining the vertical structure of atmospheric aerosols and their related optical properties. To investigate the characterization of atmospheric aerosols (especially bioaerosols) with high spatial and temporal resolution, we developed a Raman/fluorescence/polarization lidar system employed a multi-channel spectrometer, with capabilities of providing measurements of Raman scattering and laser-induced fluorescence excitation at 355 nm from atmospheric aerosols. Meanwhile, the lidar system operated polarization measurements both at 355nm and 532nm wavelengths, aiming to obtain more information of aerosols. It employs a high power pulsed laser and a received telescope with 350mm diameter. The receiver could simultaneously detect a wide fluorescent spectrum about 178 nm with spectral resolution 5.7 nm, mainly including an F/3.7 Crossed Czerny-Turner spectrograph, a grating (1200 gr/mm) and a PMT array with 32 photocathode elements. Vertical structure of fluorescent aerosols in the atmosphere was observed by the developed lidar system at four sites across northwest China, during 2014 spring field observation that conducted by Lanzhou University. It has been proved that the developed lidar could detect the fluorescent aerosols with high temporal and

  15. Mobile low power total reflexion x-ray fluorescence spectrometer with pg-detection-limit

    Energy Technology Data Exchange (ETDEWEB)

    Dietsch, R.; Holz, Th.; Mai, H. [Fraunhofer Institute Material and Beam Technology, Dresden, (Germany); Waldschlaeger, U. [I.U.T. GmbH, Berlin, (Germany)

    1999-12-01

    Full text: Total reflexion x-ray fluorescence (TXRF) spectrometry is an efficient tool in trace element analysis. Conventional laboratory spectrometers can achieve detection limits in the pg-range. Unfortunately high power X-ray tubes (i.e. some kW) and LN{sub 2}-cooled Si(Li)-detectors are sometimes not applicable within mobile TXRF-spectrometers. Therefore a portable device for TXRF (PicoTAX{sub PS}) has been developed and the latest results will be presented. This device is a very compact combination of an air-cooled low power X-ray tube (Mo-anode, 40W) a Peltier-cooled PlN-diode detector and a high quality flat primary Ni/C X-ray mirror (2t= 7.84 nm, N100, R> 80%). The background radiation is reduced by means of this particular mirror. That way the achievable detection limits are comparable with conventional 1.5 kW TXRF- spectrometers. The characteristic parameters of X-ray source, detector and Ni/C mirror will be presented. Additionally, the performance of this portable TXRF-system will be demonstrated by selected examples. Copyright (1999) Australian X-ray Analytical Association Inc. 1 fig.

  16. A portable semi-micro-X-ray fluorescence spectrometer for archaeometrical studies

    Science.gov (United States)

    Zarkadas, Ch.; Karydas, A. G.

    2004-10-01

    A portable semi-micro-X-ray fluorescence (μ-XRF) spectrometer was developed in the Laboratory for Material Analysis of the N.C.S.R "Demokritos". It utilizes a novel end-window, battery-operated, low-power X-ray tube (40 kV, 40 μA) with Au as anode material, a peltier cooled Si-PIN X-ray detector and associated electronics. The unique design of the probe-like X-ray tube anode allows very close coupling of any optical component to the tube anode, as well as to the sample position. A 240 μm pin-hole collimator was used to form the semi-microbeam. Monte Carlo calculations, as well as several sets of measurements, were performed, in order to determine the optimum geometrical and operational parameters. Preliminary results about the performance of our spectrometer are presented and compared to those reported in the literature for other micro-XRF instruments utilizing various optical elements (pin-holes, poly-capillary lenses) for focusing X-rays. The potential of this semi-micro-XRF spectrometer in the archaeometrical research is also discussed.

  17. Downsizing of Johansson spectrometer for X-ray fluorescence trace analysis with brilliant undulator source

    CERN Document Server

    Sakurai, K; Inoue, K; Yagi, N

    2001-01-01

    The downsizing of a Johansson-type X-ray fluorescence (XRF) spectrometer has been examined as a way of enhancing detection efficiency with a tolerable loss of energy resolution. A compact spectrometer equipped with a Ge(2 2 0) analyzing crystal with a Rowland radius of 120 mm has been tested with a highly brilliant helical undulator source at BL40XU, SPring-8. The energy resolution obtained for cobalt K alpha sub 1 (6930.32 eV) was 8.8 eV, which is 10-20 times better than that obtained using a Si(Li) detector, and effectively improved the signal-to-background ratio for XRF spectra. The combination of the present spectrometer and a third generation synchrotron source could provide new opportunities for trace analytical applications, which have been difficult so far by conventional synchrotron XRF experiments based on a Si(Li) detector system. The detection limit obtained for solid bulk samples has reached a level of several tens of ppb.

  18. Multi-element analysis by portable total reflection X-ray fluorescence spectrometer.

    Science.gov (United States)

    Liu, Ying; Imashuku, Susumu; Kawai, Jun

    2013-01-01

    Multi-element solutions containing the 11 elements S, K, Sc, V, Mn, Co, Cu, Ga, As, Br and Y were analyzed by a portable total reflection X-ray fluorescence (TXRF) spectrometer. The excitation parameters (glancing angle, operational voltage and current) and sample amount were optimized for the portable TXRF in order to realize the smallest possible detection limits for all elements. The excitation parameter dependencies of the fluorescence signal and background for the detected elements are explained in detail. Background contributed by the sample carrier is also discussed. Consequently, nine elements were detectable at sub-nanogram levels in a single measurement of 10 min under the optimal experimental conditions. The portable TXRF spectrometer was found to be suitable for simultaneous multi-element analysis with low detection limits. The features of high sensitivity, small sample amount required, and fast detection of a wide range of elements make the portable TXRF a valuable tool in various applications, such as field studies in environmental and geological investigations.

  19. spectrometer

    Directory of Open Access Journals (Sweden)

    J. K. Hedelius

    2016-08-01

    Full Text Available Bruker™ EM27/SUN instruments are commercial mobile solar-viewing near-IR spectrometers. They show promise for expanding the global density of atmospheric column measurements of greenhouse gases and are being marketed for such applications. They have been shown to measure the same variations of atmospheric gases within a day as the high-resolution spectrometers of the Total Carbon Column Observing Network (TCCON. However, there is little known about the long-term precision and uncertainty budgets of EM27/SUN measurements. In this study, which includes a comparison of 186 measurement days spanning 11 months, we note that atmospheric variations of Xgas within a single day are well captured by these low-resolution instruments, but over several months, the measurements drift noticeably. We present comparisons between EM27/SUN instruments and the TCCON using GGG as the retrieval algorithm. In addition, we perform several tests to evaluate the robustness of the performance and determine the largest sources of errors from these spectrometers. We include comparisons of XCO2, XCH4, XCO, and XN2O. Specifically we note EM27/SUN biases for January 2015 of 0.03, 0.75, –0.12, and 2.43 % for XCO2, XCH4, XCO, and XN2O respectively, with 1σ running precisions of 0.08 and 0.06 % for XCO2 and XCH4 from measurements in Pasadena. We also identify significant error caused by nonlinear sensitivity when using an extended spectral range detector used to measure CO and N2O.

  20. [Establishment and Improvement of Portable X-Ray Fluorescence Spectrometer Detection Model Based on Wavelet Transform].

    Science.gov (United States)

    Li, Fang; Wang, Ji-hua; Lu, An-xiang; Han, Ping

    2015-04-01

    The concentration of Cr, Cu, Zn, As and Pb in soil was tested by portable X-ray fluorescence spectrometer. Each sample was tested for 3 times, then after using wavelet threshold noise filtering method for denoising and smoothing the spectra, a standard curve for each heavy metal was established according to the standard values of heavy metals in soil and the corresponding counts which was the average of the 3 processed spectra. The signal to noise ratio (SNR), mean square error (MSE) and information entropy (H) were taken to assess the effects of denoising when using wavelet threshold noise filtering method for determining the best wavelet basis and wavelet decomposition level. Some samples with different concentrations and H3 B03 (blank) were chosen to retest this instrument to verify its stability. The results show that: the best denoising result was obtained with the coif3 wavelet basis at the decomposition level of 3 when using the wavelet transform method. The determination coefficient (R2) range of the instrument is 0.990-0.996, indicating that a high degree of linearity was found between the contents of heavy metals in soil and each X-ray fluorescence spectral characteristic peak intensity with the instrument measurement within the range (0-1,500 mg · kg(-1)). After retesting and calculating, the results indicate that all the detection limits of the instrument are below the soil standards at national level. The accuracy of the model has been effectively improved, and the instrument also shows good precision with the practical application of wavelet transform to the establishment and improvement of X-ray fluorescence spectrometer detection model. Thus the instrument can be applied in on-site rapid screening of heavy metal in contaminated soil.

  1. Computer programmes for the control and data manipulation of a sequential x-ray-fluorescence spectrometer

    International Nuclear Information System (INIS)

    Spimpolo, G.F.

    1984-01-01

    Two computer programmes have been written for use on a fully automated Siemens SRS200 sequential X-ray-fluorescence spectrometer. The first of these is used to control the spectrometer via an LC200 logic controller using a Data General Nova IV minicomputer; the second is used for the on-line evaluation of the intensity results and the printout of the analytical results. This system is an alternative to the systems offered by Siemens Ltd, which consist of a Process PR310 or Digital DEC PDP1103 computer and the Siemens Spectra 310 software package. The multibatch capabilities of the programmes, with the option of measuring one sample or a tray of samples before the results are calculated, give the new programmes a major advantage over the dedicated software and, together with the elimination of human error in calculation, have resulted in increased efficiency and quality in routine analyses. A description is given of the two programmes, as well as instruction and guidelines to the user

  2. LabVIEW control software for scanning micro-beam X-ray fluorescence spectrometer.

    Science.gov (United States)

    Wrobel, Pawel; Czyzycki, Mateusz; Furman, Leszek; Kolasinski, Krzysztof; Lankosz, Marek; Mrenca, Alina; Samek, Lucyna; Wegrzynek, Dariusz

    2012-05-15

    Confocal micro-beam X-ray fluorescence microscope was constructed. The system was assembled from commercially available components - a low power X-ray tube source, polycapillary X-ray optics and silicon drift detector - controlled by an in-house developed LabVIEW software. A video camera coupled to optical microscope was utilized to display the area excited by X-ray beam. The camera image calibration and scan area definition software were also based entirely on LabVIEW code. Presently, the main area of application of the newly constructed spectrometer is 2-dimensional mapping of element distribution in environmental, biological and geological samples with micrometer spatial resolution. The hardware and the developed software can already handle volumetric 3-D confocal scans. In this work, a front panel graphical user interface as well as communication protocols between hardware components were described. Two applications of the spectrometer, to homogeneity testing of titanium layers and to imaging of various types of grains in air particulate matter collected on membrane filters, were presented. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Improvement of total reflection X-ray fluorescence spectrometer sensitivity by flowing nitrogen gas

    Science.gov (United States)

    Imashuku, Susumu; Tee, Deh Ping; Kawai, Jun

    2012-07-01

    The intensity of Ar Kα line was reduced by a factor of 17 times by flowing more than 400 mL min- 1 of N2 gas through gas pipe placed at the gap between the X-ray detector and the sample stage of the total reflection X-ray fluorescence (TXRF) spectrometer. The signal-to-background ratios of characteristic X-rays with energies less than 8 keV were improved by flowing N2 gas owing to the reduction of peak pileups related to the Ar Kα peak. The improvement of the signal-to-background ratios became significant as the energies of the characteristic X-rays approached that of the Ar Kα line (2.96 keV) for characteristic X-rays with energies less than 5 keV. When 1 μL of solution containing 10 mg L- 1 cadmium (10 ng) was measured with the TXRF spectrometer by flowing N2 gas, Cd Lα line was clearly observed, although the Cd Lα line overlapped with the Ar K lines without flowing N2 gas. The lower limit of detection of cadmium evaluated from the Cd Lα line was improved from 7.0 to 2.2 ng by flowing N2 gas. This N2 gas flowing technique can be applied to trace element analysis of cadmium in solutions which do not contain potassium such as leaching solutions from products containing cadmium in TXRF and conventional XRF measurements.

  4. Dual x-ray fluorescence spectrometer and method for fluid analysis

    Science.gov (United States)

    Wilson, Bary W.; Shepard, Chester L.

    2005-02-22

    Disclosed are an X-ray fluorescence (SRF) spectrometer and method for on-site and in-line determination of contaminant elements in lubricating oils and in fuel oils on board a marine vessel. An XRF source block 13 contains two radionuclide sources 16, 17 (e.g. Cd 109 and Fe 55), each oriented 180 degrees from the other to excite separate targets. The Cd 109 source 16 excites sample lube oil flowing through a low molecular weight sample line 18. The Fe 55 source 17 excites fuel oil manually presented to the source beam inside a low molecular weight vial 26 or other container. Two separate detectors A and B are arranged to detect the fluorescent x-rays from the targets, photons from the analyte atoms in the lube oil for example, and sulfur identifying x-rays from bunker fuel oil for example. The system allows both automated in-line and manual on-site analysis using one set of signal processing and multi-channel analyzer electronics 34, 37 as well as one computer 39 and user interface 43.

  5. Total reflection x-ray fluorescence spectrometers for multielemental analysis: status of commercial equipment

    International Nuclear Information System (INIS)

    Ayala Jimenez, R.E.

    2000-01-01

    Multi-elemental analysis by total reflection x-ray fluorescence spectrometry has evolved during two decades. At the present there are commercial equipment available for the chemical analysis in all kind of biological and mineral samples. The electronic industry has also been benefited from the scientific and technological developments in the field of TXRF. The basic components of the spectrometers can be summarized as follow: a) excitation source; b) geometric arrangement (optics) for collimation and monochromatization of the primary radiation; c) x-ray detector; d) hardware and software for operation of the instrument, data acquisition and spectral deconvolution to determine the concentrations of the element present in the sample (quantitative analysis). As optional there are manufacturers offering the conventional 45 degrees geometry for direct excitation of bulky liquid or solid samples. Personal communications of the author and the commercial brochures available at the moment of writing this presentation have allowed to list the following type of components used in the TXRF spectrometers for multi-elemental analysis (the devices used in the electronic industry to analyze silicon wafers are excluded). Excitation: high power x-ray tube, output from 1300 to 2000 watts; metal ceramic low power-ray tube, output up to 50 watts. Different anodes are used but molybdenum, tungsten and copper are frequent. The excitation systems can be customized according to the requirements of the laboratory. Detector: Si-Li semi-conductor liquid nitrogen cooled; silicon solid state thermoelectrically cooled (silicon drift detector SDD and Si-PIN diode). Optics: multilayer monochromator of Si-W or Ni-C; double multilayer monochromator. Electronics: spectroscopy amplifier, analog to digital converter adapted to a PC compatible computer with software in Windows environment for the whole operation of the spectrometer and for qualy/quantitative analysis of samples are standards in the

  6. A portable microfluidic fluorescence spectrometer device for γ-H2AX-based biological dosimetry

    International Nuclear Information System (INIS)

    Pope, I.A.; Barber, P.R.; Horn, S.; Ainsbury, E.; Rothkamm, K.; Vojnovic, B.

    2011-01-01

    Following a radiological incident the rapid identification of those individuals exposed to critically high radiation doses is important for initial triage and medical treatment. It has been previously demonstrated that scoring of radiation-induced foci of the phosphorylated histone γ-H2AX, which form at the sites of DNA double-strand breaks, may be used to determine radiation exposure levels from blood samples. Although faster than the 'gold standard' dicentric assay, foci scoring is still impractical in a field situation where large numbers of people may need to be screened. To deal with such a situation, an inexpensive portable device with high throughput capacity is desirable. Here we describe a portable microfluidic fluorescence spectrometer device which passes a suspension of γ-H2AX immunofluorescence-stained lymphocytes through a focused 488 nm laser beam in a microfluidic chamber and records emission spectra over the range 495-725 nm. The recorded emission spectra are spectrally unmixed into their constituent parts from which radiation exposure levels are determined. Proof of principle is demonstrated using cultured lymphoblastoid cells, exposed to X-ray doses between 0 and 8 Gy. With the current prototype setup it takes approximately 6 min to acquire and analyse 10,000 spectra. Further effort is required to fully develop this approach into a portable triage tool that could be used to help classify people into appropriate treatment categories based on radiation exposure levels.

  7. TX 2000: total reflection and 45o energy dispersive x-ray fluorescence spectrometer

    International Nuclear Information System (INIS)

    Pasti, F.; Torboli, A.; Valdes, M.

    2000-01-01

    This equipment, developed by Ital Structures, combines two kinds of energy dispersive X-ray fluorescence techniques, the first using total reflection geometry and the second conventional 45 o geometry. The equipment is completely controlled by a PC and to reach the condition of total reflection is very easy because it is enough to load the file with the right position for the corresponding energy. In this apparatus we used an x-ray tube with an alloy anode of Mo/W with a long fine focus at 2200 W. To monochromatize the x-ray beam while choosing, for example, the Mo K alpha or W L alpha or a piece of white spectrum of 33 keV, we use a highly reflective multilayer made of Si/W with 2d = 45.5 A o . The detector used in the equipment is a lithium drifted silicon detector (Si(Li)) with an excellent energy resolution of 135 eV at 5.9 keV and 1000 cps. We developed two programs written in Windows 95, 98 and NT for a 32 bit microprocessor. The first one is called TYACQ32 and has the following functions: first, complete control of the hardware, second automatic alignment of the TX 2000 spectrometer and third acquisition of spectra. The second program is EDXRF32. This is a program to accomplish spectrum and quantitative analysis for TXRF and EDXRF 45 o degrees analysis. (author)

  8. An imaging X-ray fluorescence spectrometer for near earth objects

    International Nuclear Information System (INIS)

    Martin, A.P.; Brunton, A.N.; Fraser, G.W.

    1999-01-01

    We propose a novel imaging X-ray spectrometer to be flown on a space mission to a Near Earth Object (NEO) (the Moon, a near Earth asteroid or a comet). In either of the first two cases the instrument will record X-ray fluorescence excited from the surface by the solar X-ray flux to form 'compositional maps' of its surface, providing valuable information on the evolution of these objects. In the case of a comet, the device will study the X-ray emission resulting from its interaction with the solar wind. During cruise when the spacecraft is en-route to the NEO the instrument will be used to make astronomical observations of Active Galactic Nuclei (AGN), X-ray binary stars and coronal sources in star clusters such as the Pleiades or Hyades. The instrument, proposed for ESA's SMART-1 mission, is a miniature telescope, of 37.5 cm focal length, based on microchannel plate (MCP) optics and charged coupled device (CCD) detectors providing both imaging and a medium resolution ∼50-100 eV spectroscopic capability; sufficient to resolve the L lines of Ca, Ti, Fe, and the K lines of O, Mg, Al and Si with an angular resolution ∼10 arcmin and a 6x6 deg. field of view

  9. A portable total reflection X-ray fluorescence spectrometer with a diamond-like carbon coated X-ray reflector.

    Science.gov (United States)

    Kunimura, Shinsuke; Ohmori, Hitoshi

    2012-01-21

    A diamond-like carbon (DLC) coated quartz glass sample holder is used in a portable total reflection X-ray fluorescence (TXRF) spectrometer. A spot area of a water sample on the DLC sample holder becomes smaller than that on a quartz glass sample holder usually used in TXRF analysis because DLC is more hydrophobic. Therefore, the use of the DLC sample holder enhances fluorescent X-rays reaching a detector compared with the use of a quartz glass sample holder, leading to improvement in detection sensitivity. A detection limit of 28 pg is achieved for Cr in a river water sample when using the DLC sample holder.

  10. Improvement of total reflection X-ray fluorescence spectrometer sensitivity by flowing nitrogen gas

    Energy Technology Data Exchange (ETDEWEB)

    Imashuku, Susumu, E-mail: imashuku.susumu.2m@kyoto-u.ac.jp; Tee, Deh Ping; Kawai, Jun

    2012-07-15

    The intensity of Ar K{alpha} line was reduced by a factor of 17 times by flowing more than 400 mL min{sup -1} of N{sub 2} gas through gas pipe placed at the gap between the X-ray detector and the sample stage of the total reflection X-ray fluorescence (TXRF) spectrometer. The signal-to-background ratios of characteristic X-rays with energies less than 8 keV were improved by flowing N{sub 2} gas owing to the reduction of peak pileups related to the Ar K{alpha} peak. The improvement of the signal-to-background ratios became significant as the energies of the characteristic X-rays approached that of the Ar K{alpha} line (2.96 keV) for characteristic X-rays with energies less than 5 keV. When 1 {mu}L of solution containing 10 mg L{sup -1} cadmium (10 ng) was measured with the TXRF spectrometer by flowing N{sub 2} gas, Cd L{alpha} line was clearly observed, although the Cd L{alpha} line overlapped with the Ar K lines without flowing N{sub 2} gas. The lower limit of detection of cadmium evaluated from the Cd L{alpha} line was improved from 7.0 to 2.2 ng by flowing N{sub 2} gas. This N{sub 2} gas flowing technique can be applied to trace element analysis of cadmium in solutions which do not contain potassium such as leaching solutions from products containing cadmium in TXRF and conventional XRF measurements. - Highlights: Black-Right-Pointing-Pointer Intensity of Ar K{alpha} line was decreased by a factor of 17 times by flowing N{sub 2} gas. Black-Right-Pointing-Pointer S/N of characteristic X-rays with energies less than 8 keV were improved. Black-Right-Pointing-Pointer Detection limit of cadmium calculated from Cd L{alpha} line was improved from 7.0 to 2.2 ng by flowing N{sub 2} gas. Black-Right-Pointing-Pointer This technique can be applied to trace element analysis of Cd in leaching solutions.

  11. Development of portable X-ray diffractometer equipped with X-ray fluorescence spectrometer and its application to archaeology

    International Nuclear Information System (INIS)

    Yamashita, Daisuke; Ishizaki, Atsushi; Uda, Masayuki

    2009-01-01

    A portable X-ray diffractometer equipped with an X-ray fluorescence spectrometer was improved so as to obtain a diffraction pattern and a fluorescence spectrum in air from one and the same small area of a specimen. The reason why the portable XRD with an XRF spectrometer was specially designed for archaeology may be understood from the following facts: (1) some objects exhibited in museums are not allowed to be transferred from the open air to a vacuum, even if their volumes are small; (2) some objects are very difficult to move from their original sites; (3) some parts of exhibits are extremely fragile and cannot be examined in a vacuum; and (4) information on the chemical composition and structure from the same area of an object offers a better understanding of the constitutive materials of the object. Some examples of the use of a portable X-ray diffractometer equipped with an X-ray fluorescence spectrometer in the field are also introduced. Experimental results of Sho-kannon, Snew's mask and Tutankhamun's golden mask are shown here. (author)

  12. Design, manufacturing and alignment of a fluorescence imaging spectrometer based on refractive optics and a transmission grating

    Science.gov (United States)

    Lousberg, G. P.; Lemagne, F.; Gloesener, P.; Flebus, C.; Rougelot, S.; Coatantiec, C.; Harnisch, B.

    2017-11-01

    In the framework of the Fluorescence Explorer (FLEX) phase A/B1 study, an elegant breadboard (EBB) of an imaging spectrometer is designed, manufactured and aligned by AMOS, with Airbus Defence&Space as the prime Contractor of the study. The FLEX mission is one of the two candidates of the 8th Earth Explorer mission. The main constituting instrument of the FLEX mission is an imaging spectrometer observing vegetation fluorescence and reflectance with a high- and a low-resolution channels in the 500 nm -780 nm band. As part of the system feasibility study of the mission, a breadboard of the high-resolution channel of the instrument is designed and manufactured with a high representativeness of a future flight concept. The high-resolution channel is referred to as FIMAS (Fluorescence IMAging Spectrometer). The main purpose of the EBB is to demonstrate (1) the manufacturability of the instrument and (2) the compliance of the optical performances with respect to the science requirements (including spatial and spectral resolution and stray-light).

  13. Innovative optical spectrometers for ice core sciences and atmospheric monitoring at polar regions

    Science.gov (United States)

    Grilli, Roberto; Alemany, Olivier; Chappellaz, Jérôme; Desbois, Thibault; Faïn, Xavier; Kassi, Samir; Kerstel, Erik; Legrand, Michel; Marrocco, Nicola; Méjean, Guillaume; Preunkert, Suzanne; Romanini, Daniele; Triest, Jack; Ventrillard, Irene

    2015-04-01

    In this talk recent developments accomplished from a collaboration between the Laboratoire Interdisciplinaire de Physique (LIPhy) and the Laboratoire de Glaciologie et Géophysique de l'Environnement (LGGE) both in Grenoble (France), are discussed, covering atmospheric chemistry of high reactive species in polar regions and employing optical spectrometers for both in situ and laboratory measurements of glacial archives. In the framework of an ANR project, a transportable spectrometer based on the injection of a broadband frequency comb laser into a high-finesse optical cavity for the detection of IO, BrO, NO2 and H2CO has been realized.[1] The robust spectrometer provides shot-noise limited measurements for as long as 10 minutes, reaching detection limits of 0.04, 2, 10 and 200 ppt (2σ) for the four species, respectively. During the austral summer of 2011/12 the instrument has been used for monitoring, for the first time, NO2, IO and BrO at Dumont d'Urville Station at East of Antarctica. The measurements highlighted a different chemistry between East and West coast, with the halogen chemistry being promoted to the West and the OH and NOx chemistry on the East.[2] In the framework of a SUBGLACIOR project, an innovative drilling probe has been realized. The instrument is capable of retrieving in situ real-time vertical profiles of CH4 and δD of H2O trapped inside the ice sheet down to more than 3 km of depth within a single Antarctic season. The drilling probe containing an embedded OFCEAS (optical-feedback cavity-enhanced absorption spectroscopy) spectrometer will be extremely useful for (i) identify potential sites for investigating the oldest ice (aiming 1.5 Myrs BP records for resolving a major climate reorganization called the Mid-Pleistocene transition occurred around 1 Myrs ago) and (ii) providing direct access to past temperatures and climate cycles thanks to the vertical distribution of two key climatic signatures.[3] The spectrometer provides detection

  14. Application of a portable total reflection x-ray fluorescence spectrometer to a trace elemental analysis of wines

    International Nuclear Information System (INIS)

    Kunimura, Shinsuke; Kawai, Jun

    2009-01-01

    A portable total reflection X-ray fluorescence (TXRF) spectrometer has been applied to a trace elemental analysis of wines. Sulfur, K, Mn, Fe, and Rb were detected. These five elements were quantified by using 1 ppm of Co as an internal standard. The quantified concentrations ranged from sub-ppm to several hundred ppm. Because of organic substances in wines, the scattering of the incident X-rays from the dry residues of wines becomes strong. Therefore, a high spectral background appears in TXRF spectra of wines. Because of this background, relative standard deviations of the quantified concentrations were from 4 to 28%. Although the high spectral background appeared in the TXRF spectra of the wines, a detection limit down to several tens of ppb was achieved. The present portable spectrometer can be applied to screening for trace elements in wines before an accurate and precise analysis using a large elemental analyzer. (author)

  15. Trace Elemental Determination Using a Portable Total Reflection X-Ray Fluorescence Spectrometer with a Collodion Film Sample Holder.

    Science.gov (United States)

    Kunimura, Shinsuke; Shinkai, Tomoki

    2017-01-01

    Using a portable total-reflection X-ray fluorescence (TXRF) spectrometer with a collodion film sample holder, a spectrum of an analyte containing 50 ng of aluminum was measured. The Al Kα line (1.49 keV) that partially overlaps with the Si Kα line (1.74 keV) from a quartz glass substrate usually used as a sample holder for TXRF analysis, was clearly detected when using the collodion film sample holder. To investigate the quantitative performance of the portable spectrometer with a collodion film sample holder, the concentrations of Cr, Mn, and Fe in a certified reference material of river water (JSAC 0302-3b), whose certified values are 10.0, 5.1, and 59.6 μg/L, respectively, were determined by the internal-standard method. We showed that approximate concentrations of these elements were determined.

  16. Microfluidic Integration on Detector Array for Absorption and Fluorescence Micro-Spectrometers

    National Research Council Canada - National Science Library

    Adam, Mark L; Enzelberger, Markus; Quake, Stephen; Scherer, Axel

    2005-01-01

    .... Elastomers are excellent transparent materials, which provide hermetic seals to silicon dioxide and allow sensitive absorption and fluorescent spectroscopy in the visible and near-UV wavelength range...

  17. Laboratory Tests of a Handheld X-Ray Fluorescence Spectrometer: A Tool for Planetary Exploration

    Science.gov (United States)

    Young, K. E.; Evans, C. A.; Hodges, K.

    2011-12-01

    Maximizing the science return from a mission to another planetary surface involves the integration of science objectives with deployable technologies that enable the collection of data and samples. For long duration manned missions, it is likely that more samples will be collected than can be returned to Earth due to mass limits. A niche exists for technologies that help prioritize samples for return, provide data for future sample handling and curation, and characterization for samples that are not returned to Earth. To fill this niche, hardware and protocols for field instruments are currently being developed and evaluated at NASA Johnson Space Center and Arizona State University. Our goal is to develop an easily used, environmentally isolated facility as part of the astronaut surface habitat for preliminary sample characterization and down-selection. NASA has constructed a prototype, GeoLab, as a testbed for evaluating the scientific applicability and operational considerations of various analytical instruments. One instrument under evaluation is a small, portable x-ray fluorescence (XRF) spectrometer that can be also be used by astronaut explorers as part of their field gear while on scientific sorties, or on robotic field assistants. We report on preliminary usability tests for commercially available handheld XRF instruments. These instruments collect data by contacting the surface of a rock or sediment sample with an 8 mm-wide sensor window. Within 60 seconds, the devices can provide relatively precise data on the abundance of major and trace elements heavier than Na. Lab-based handheld XRF analyses of terrestrial and lunar samples, compared with those made with full-scale laboratory XRF systems, show good correlation, but we continue to investigate potential sources of error and the need for careful calibration with standards of known composition. Specifically, we use a suite of five terrestrial and five lunar basalts, all well characterized by conventional

  18. Detecting Metallic Primary Explosives with a Portable X-ray Fluorescence Spectrometer

    National Research Council Canada - National Science Library

    Hewitt, Alan D

    1997-01-01

    X-ray fluorescence spectrometry (XRF) analysis is a practical means of performing in-situ screening to establish the presence of high concentrations (>0.1% or 1000 ppm) of lead (Pb) and/or mercury (Hg...

  19. Static Hyperspectral Fluorescence Imaging of Viscous Materials Based on a Linear Variable Filter Spectrometer

    Directory of Open Access Journals (Sweden)

    Alexander W. Koch

    2013-09-01

    Full Text Available This paper presents a low-cost hyperspectral measurement setup in a new application based on fluorescence detection in the visible (Vis wavelength range. The aim of the setup is to take hyperspectral fluorescence images of viscous materials. Based on these images, fluorescent and non-fluorescent impurities in the viscous materials can be detected. For the illumination of the measurement object, a narrow-band high-power light-emitting diode (LED with a center wavelength of 370 nm was used. The low-cost acquisition unit for the imaging consists of a linear variable filter (LVF and a complementary metal oxide semiconductor (CMOS 2D sensor array. The translucent wavelength range of the LVF is from 400 nm to 700 nm. For the confirmation of the concept, static measurements of fluorescent viscous materials with a non-fluorescent impurity have been performed and analyzed. With the presented setup, measurement surfaces in the micrometer range can be provided. The measureable minimum particle size of the impurities is in the nanometer range. The recording rate for the measurements depends on the exposure time of the used CMOS 2D sensor array and has been found to be in the microsecond range.

  20. Airborne laser induced fluorescence imaging. Innovative technology summary report

    International Nuclear Information System (INIS)

    1999-06-01

    Laser-Induced Fluorescence (LIF) was demonstration as part of the Fernald Environmental Management Project (FEMP) Plant 1 Large Scale Demonstration and Deployment Project (LSDDP) sponsored by the US Department of Energy (DOE) Office of Science and Technology, Deactivation and Decommissioning Focus Area located at the Federal Energy Technology Center (FETC) in Morgantown, West Virginia. The demonstration took place on November 19, 1996. In order to allow the contaminated buildings undergoing deactivation and decommissioning (D and D) to be opened to the atmosphere, radiological surveys of floors, walls and ceilings must take place. After successful completion of the radiological clearance survey, demolition of the building can continue. Currently, this process is performed by collecting and analyzing swipe samples for radiological analysis. Two methods are used to analyze the swipe samples: hand-held frisker and laboratory analysis. For the purpose of this demonstration, the least expensive method, swipe samples analyzed by hand-held frisker, is the baseline technology. The objective of the technology demonstration was to determine if the baseline technology could be replaced using LIF

  1. Development of a silicon drift detector array: an x-ray fluorescence spectrometer for remote surface mapping

    Science.gov (United States)

    Gaskin, Jessica A.; Carini, Gabriella A.; Chen, Wei; De Geronimo, Gianluigi; Elsner, Ronald F.; Keister, Jeffrey W.; Kramer, Georgiana; Li, Zheng; Ramsey, Brian D.; Rehak, Pavel; Siddons, D. Peter

    2009-08-01

    Over the past three years NASA Marshall Space Flight Center has been collaborating with Brookhaven National Laboratory to develop a modular Silicon Drift Detector (SDD) X-Ray Spectrometer (XRS) intended for fine surface mapping of the light elements of the moon. The value of fluorescence spectrometry for surface element mapping is underlined by the fact that the technique has recently been employed by three lunar orbiter missions; Kaguya, Chandrayaan-1, and Chang'e. The SDD-XRS instrument we have been developing can operate at a low energy threshold (i.e. is capable of detecting Carbon), comparable energy resolution to Kaguya (<150 eV at 5.9 keV) and an order of magnitude lower power requirement, making much higher sensitivities possible. Furthermore, the intrinsic radiation resistance of the SDD makes it useful even in radiation-harsh environments such as that of Jupiter and its surrounding moons.

  2. Development of a Silicon Drift Detector Array: An X-ray Fluorescence Spectrometer for Remote Surface Mapping

    Energy Technology Data Exchange (ETDEWEB)

    Gaskin, J.A.; De Geronimo, G.; Carini, G.A.; Chen, W.; Elsner, R.F.; Kramer, G.; Keister, J.W.; Li, Z.; Ramsey, B.D.; Rehak, P.; Siddons, D.P.

    2009-09-11

    Over the past three years NASA Marshall Space Flight Center has been collaborating with Brookhaven National Laboratory to develop a modular Silicon Drift Detector (SDD) X-Ray Spectrometer (XRS) intended for fine surface mapping of the light elements of the moon. The value of fluorescence spectrometry for surface element mapping is underlined by the fact that the technique has recently been employed by three lunar orbiter missions; Kaguya, Chandrayaan-1, and Chang'e. The SDD-XRS instrument we have been developing can operate at a low energy threshold (i.e. is capable of detecting Carbon), comparable energy resolution to Kaguya (<150 eV at 5.9 keV) and an order of magnitude lower power requirement, making much higher sensitivities possible. Furthermore, the intrinsic radiation resistance of the SDD makes it useful even in radiation-harsh environments such as that of Jupiter and its surrounding moons.

  3. Development of a Silicon Drift Detector Array: An X-ray Fluorescence Spectrometer for Remote Surface Mapping

    International Nuclear Information System (INIS)

    Gaskin, J.A.; De Geronimo, G.; Carini, G.A.; Chen, W.; Elsner, R.F.; Kramer, G.; Keister, J.W.; Li, Z.; Ramsey, B.D.; Rehak, P.; Siddons, D.P.

    2009-01-01

    Over the past three years NASA Marshall Space Flight Center has been collaborating with Brookhaven National Laboratory to develop a modular Silicon Drift Detector (SDD) X-Ray Spectrometer (XRS) intended for fine surface mapping of the light elements of the moon. The value of fluorescence spectrometry for surface element mapping is underlined by the fact that the technique has recently been employed by three lunar orbiter missions; Kaguya, Chandrayaan-1, and Chang'e. The SDD-XRS instrument we have been developing can operate at a low energy threshold (i.e. is capable of detecting Carbon), comparable energy resolution to Kaguya (<150 eV at 5.9 keV) and an order of magnitude lower power requirement, making much higher sensitivities possible. Furthermore, the intrinsic radiation resistance of the SDD makes it useful even in radiation-harsh environments such as that of Jupiter and its surrounding moons.

  4. Trace elemental analysis of commercial bottled drinking water by a portable total reflection X-ray fluorescence spectrometer.

    Science.gov (United States)

    Kunimura, Shinsuke; Kawai, Jun

    2007-10-01

    A portable total reflection X-ray fluorescence spectrometer was applied to commercial bottled drinking water containing 62 ppb (microg/L) V, 7.5 ppm (mg/L) Ca, and 1 ppm K. A dry residue, prepared by repeated pipetting and drying a 20 microL portion of drinking water on a sample holder six times, and another dry residue, prepared by pipetting and drying a 120 microL portion of the drinking water, were measured. The size of the dry residue of the drinking water was reduced by repeating the pipetting and drying. Calcium and potassium were easily detected in these two dry residues. Vanadium was detected in the dry residue prepared by repeated pipetting and drying. Vanadium, calcium, and potassium were quantified by using an internal standard, and the average quantified concentrations of V, Ca, and K were 91 ppb, 8.2 ppm, and 1.5 ppm, respectively. Although these quantified concentrations deviated from the certified concentrations (62 ppb of V, 7.5 ppm of Ca, and 1 ppm of K), it was possible for this portable spectrometer to estimate approximate concentrations.

  5. Development of Standard Samples for on-board Calibration of a New Planetary X-Ray Fluorescence Spectrometer

    Science.gov (United States)

    Dreißigacker, Anne; Köhler, Eberhard; Fabel, Oliver; van Gasselt, Stephan

    2014-05-01

    At the Planetary Sciences and Remote Sensing research group at Freie Universität Berlin an SCD-based X-Ray Fluorescence Spectrometer is being developed to be employed on planetary orbiters to conduct direct, passive energy-dispersive x-ray fluorescence measurements of planetary surfaces through measuring the emitted X-Ray fluorescence induced by solar x-rays and high energy particles. Because the Sun is a highly variable radiation source, the intensity of solar X-Ray radiation has to be monitored constantly to allow for comparison and signal calibration of X-Ray radiation from lunar surface materials. Measurements are obtained by indirectly monitoring incident solar x-rays emitted from a calibration sample. This has the additional advantage of minimizing the risk of detector overload and damage during extreme solar events such as high-energy solar flares and particle storms as only the sample targets receive the higher radiation load directly (while the monitor is never directly pointing towards the Sun). Quantitative data are being obtained and can be subsequently analysed through synchronous measurement of fluorescence of the Moon's surface by the XRF-S main instrument and the emitted x-ray fluorescence of calibration samples by the XRF-S-ISM (Indirect Solar Monitor). We are currently developing requirements for 3 sample tiles for onboard correction and calibration of XRF-S, each with an area of 3-9 cm2 and a maximum weight of 45 g. This includes development of design concepts, determination of techniques for sample manufacturing, manufacturing and testing of prototypes and statistical analysis of measurement characteristics and quantification of error sources for the advanced prototypes and final samples. Apart from using natural rock samples as calibration sample, we are currently investigating techniques for sample manufacturing including laser sintering of rock-glass on metals, SiO2-stabilized mineral-powders, or artificial volcanic glass. High precision

  6. Confocal X-ray fluorescence spectrometer for in-situ analyses of paintings

    Science.gov (United States)

    Trojek, Tomáš; Prokeš, Radek; Šefců, Radka; Bilavčíková, Hana; Čechák, Tomáš

    2017-08-01

    This paper describes the properties of the newly constructed device for confocal X-ray fluorescence analysis that was tested with a sample plate consisting of 19 combinations of two single pigment layers. The preparation of this experimental wooden board with layered systems was based on knowledge of the panel painting techniques of Bohemian collections from the National Gallery in Prague dating back to the 14th and 15th centuries. The design of the confocal setup allows its transport and the in-situ measurement of paintings in depositories or even in exhibition areas. The advantages of our confocal setup with movable collimating optics are also described.

  7. Environmental trace-element analysis using a benchtop total reflection X-ray fluorescence spectrometer.

    Science.gov (United States)

    Stosnach, Hagen

    2005-07-01

    Total reflection X-ray fluorescence (TXRF) analysis is an established technique for trace-element analysis in various types of samples. Though expensive large-scale systems restricted the applications in the past, in this study the capability of a benchtop system for trace elemental analysis is reported. The suitability of this system for the mobile on-site analysis of heavy metal contaminated soils and sediments is reported as well as the possibilities and restrictions of TXRF for additional applications, including trace-element analysis of water, glass and biological samples.

  8. Laboratory-based micro-X-ray fluorescence setup using a von Hamos crystal spectrometer and a focused beam X-ray tube

    International Nuclear Information System (INIS)

    Kayser, Y.; Błachucki, W.; Dousse, J.-Cl.; Hoszowska, J.; Neff, M.; Romano, V.

    2014-01-01

    The high-resolution von Hamos bent crystal spectrometer of the University of Fribourg was upgraded with a focused X-ray beam source with the aim of performing micro-sized X-ray fluorescence (XRF) measurements in the laboratory. The focused X-ray beam source integrates a collimating optics mounted on a low-power micro-spot X-ray tube and a focusing polycapillary half-lens placed in front of the sample. The performances of the setup were probed in terms of spatial and energy resolution. In particular, the fluorescence intensity and energy resolution of the von Hamos spectrometer equipped with the novel micro-focused X-ray source and a standard high-power water-cooled X-ray tube were compared. The XRF analysis capability of the new setup was assessed by measuring the dopant distribution within the core of Er-doped SiO 2 optical fibers

  9. Laboratory-based micro-X-ray fluorescence setup using a von Hamos crystal spectrometer and a focused beam X-ray tube.

    Science.gov (United States)

    Kayser, Y; Błachucki, W; Dousse, J-Cl; Hoszowska, J; Neff, M; Romano, V

    2014-04-01

    The high-resolution von Hamos bent crystal spectrometer of the University of Fribourg was upgraded with a focused X-ray beam source with the aim of performing micro-sized X-ray fluorescence (XRF) measurements in the laboratory. The focused X-ray beam source integrates a collimating optics mounted on a low-power micro-spot X-ray tube and a focusing polycapillary half-lens placed in front of the sample. The performances of the setup were probed in terms of spatial and energy resolution. In particular, the fluorescence intensity and energy resolution of the von Hamos spectrometer equipped with the novel micro-focused X-ray source and a standard high-power water-cooled X-ray tube were compared. The XRF analysis capability of the new setup was assessed by measuring the dopant distribution within the core of Er-doped SiO2 optical fibers.

  10. Sun-induced fluorescence - a new probe of photosynthesis: First maps from the imaging spectrometer HyPlant

    Czech Academy of Sciences Publication Activity Database

    Rascher, U.; Alonso, A.; Burkart, A.; Cilia, C.; Cogliati, S.; Colombo, R.; Damm, A.; Drusch, M.; Guanter, L.; Hanuš, Jan; Hyvarinen, T.; Jullita, T.; Jussila, J.; Kataja, K.; Kokkalis, P.; Kraft, S.; Kraska, T.; Matveeva, M.; Moreno, J.; Müller, O.; Panigada, C.; Pikl, Miroslav; Pinto, F.; Prey, L.; Pude, F.; Rossini, M.; Schickling, A.; Schurr, E.; Schüttemeyer, D.; Verrlest, J.; Zemek, František

    2015-01-01

    Roč. 21, č. 12 (2015), s. 4673-4684 ISSN 1354-1013 Institutional support: RVO:67179843 Keywords : airborne measurements * chlorophyll fluorescence * FLEX * HyPlant * imaging spectroscopy * photosynthesis * remote sensing * sun-induced fluorescence * vegetation monitoring Subject RIV: EH - Ecology, Behaviour Impact factor: 8.444, year: 2015

  11. Assessment of an X-Ray Spectrometer for fluorescence cross sections measurements of elements with 22≤Ζ≤55 in a secondary target configuration

    International Nuclear Information System (INIS)

    Delabat Diaz, Y.

    2015-01-01

    A performance evaluation of an X-Ray Fluorescence Spectrometer for X-Ray Fluorescence (XRF) cross section measurements in a Secondary Target (ST) set-up has been carried out. Using Cd and Dy as STs, an annular 241 Am (∼1 Ci) radioactive source and an X-Ray Spectrometer with a Si(Li) semiconductor detector, the photon effective flux factors (Ι 0 Gε) were measured for some elements with 22≤Ζ≤55 as a function of the characteristics X-Rays energy for two different distances Source-St (0.5 cm and 1.0 cm). Thin high purity foils and a few pellets made out of composed materials were used as samples for the Ι 0 Gε calibrations. the contribution of 59.54 KeV scattered photons to the XRF was analysed and the Scattering Correction Factor (SCF) due to excitation by 59.54 keV scattered photons was estimated in the Cd configuration for further cross section measurements improvements. (Author)

  12. High energy resolution five-crystal spectrometer for high quality fluorescence and absorption measurements on an x-ray absorption spectroscopy beamline.

    Science.gov (United States)

    Llorens, Isabelle; Lahera, Eric; Delnet, William; Proux, Olivier; Braillard, Aurélien; Hazemann, Jean-Louis; Prat, Alain; Testemale, Denis; Dermigny, Quentin; Gelebart, Frederic; Morand, Marc; Shukla, Abhay; Bardou, Nathalie; Ulrich, Olivier; Arnaud, Stéphan; Berar, Jean-François; Boudet, Nathalie; Caillot, Bernard; Chaurand, Perrine; Rose, Jérôme; Doelsch, Emmanuel; Martin, Philippe; Solari, Pier Lorenzo

    2012-06-01

    Fluorescence detection is classically achieved with a solid state detector (SSD) on x-ray absorption spectroscopy (XAS) beamlines. This kind of detection however presents some limitations related to the limited energy resolution and saturation. Crystal analyzer spectrometers (CAS) based on a Johann-type geometry have been developed to overcome these limitations. We have tested and installed such a system on the BM30B/CRG-FAME XAS beamline at the ESRF dedicated to the structural investigation of very dilute systems in environmental, material and biological sciences. The spectrometer has been designed to be a mobile device for easy integration in multi-purpose hard x-ray synchrotron beamlines or even with a laboratory x-ray source. The CAS allows to collect x-ray photons from a large solid angle with five spherically bent crystals. It will cover a large energy range allowing to probe fluorescence lines characteristic of all the elements from Ca (Z = 20) to U (Z = 92). It provides an energy resolution of 1-2 eV. XAS spectroscopy is the main application of this device even if other spectroscopic techniques (RIXS, XES, XRS, etc.) can be also achieved with it. The performances of the CAS are illustrated by two experiments that are difficult or impossible to perform with SSD and the complementarity of the CAS vs SSD detectors is discussed.

  13. Improved spectrometer-microscope for quantitative fluorescence resonance energy transfer measurement based on simultaneous spectral unmixing of excitation and emission spectra.

    Science.gov (United States)

    Lin, Fangrui; Du, Mengyan; Yang, Fangfang; Wei, Lichun; Chen, Tongsheng

    2018-01-01

    Based on our recently developed quantitative fluorescence resonance energy transfer (FRET) measurement method using simultaneous spectral unmixing of excitation and emission spectra (ExEm-spFRET), we here set up an improved spectrometer-microscope (SM) for implementing modified ExEm-spFRET (mExEm-spFRET), in which a system correction factor (fsc) is introduced. Our SM system is very stable for at least six months. Implementation of mExEm-spFRET with four or two excitation wavelengths on SM for single living cells expressing different FRET constructs obtained consistent FRET efficiency (E) and acceptor-donor concentration ratio (Rc) values. We also performed mExEm-spFRET measurement for single living cells coexpressing cyan fluorescent protein (CFP)-Bax and yellow fluorescent protein (YFP)-Bax and found that the E values between CFP-Bax and YFP-Bax were very low (2.2%) and independent of Rc for control cells, indicating that Bax did not exist as homooligomer in healthy cells, but positively proportional to Rc in the case of Rc1 for staurosporine (STS)-treated cells, demonstrating that all Bax formed homooligomer after STS treatment for 6 h. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  14. The multianalyser system of the three axes neutron spectrometer PUMA: Pilot experiments with the innovative multiplex technique

    Science.gov (United States)

    Sobolev, Oleg; Hoffmann, Ron; Gibhardt, Holger; Jünke, Norbert; Knorr, Andreas; Meyer, Volker; Eckold, Götz

    2015-02-01

    A new type of multiplex technique for three axes neutron spectrometers has been realized and successfully commissioned at the PUMA spectrometer at FRM II. Consisting of eleven analyser-detector channels which can be configured individually, this technique is especially suitable for kinetic experiments where a single excitation spectrum is recorded as a function of time without the need to move the spectrometer. On a time-scale of seconds an entire spectrum can be recorded thus allowing users to monitor changes during fast kinetic processes in single shot experiments without the need for stroboscopic techniques. Moreover, the multianalyser system provides an efficient and rapid tool for mapping excitations in (Q,ω)-space. The results of pilot experiments demonstrate the performance of this new technique and a user-friendly software is presented which assists users during their experiments.

  15. Analysis of trace element compositions in adhesive cloth tapes using high-energy x-ray fluorescence spectrometer with three-dimensional polarization optics for forensic discrimination

    International Nuclear Information System (INIS)

    Goto, Akiko; Hokura, Akiko; Nakai, Izumi

    2008-01-01

    The forensic discrimination of adhesive cloth tapes often used in crimes was developed using a high-energy energy-dispersive X-ray fluorescence spectrometer with 3-dimensional polarization optics. The best measurement condition for discrimination of the tape was as follows: secondary targets, Rh and Al 2 O 3 ; measurement time, 300 s for Rh and 600 s for Al 2 O 3 ; 14 elements (Ca, Ti, Cr, Mn, Fe, Ni, Zn, Sr, Zr, Nb, Mo, Sb, Ba and Pb) were used for discrimination. It is found that the combined information of yarn density and the XRF peak intensity of the 14 elements successfully discriminated 29 out of 31 samples, of which 2 probably had the same origin. This technique is useful for forensic analysis, because it is nondestructive, rapid and easy. Therefore, it can be applied to actual forensic identification. (author)

  16. Rapid screening of heavy metals and trace elements in environmental samples using portable X-ray fluorescence spectrometer, A comparative study

    Science.gov (United States)

    McComb, Jacqueline Q.; Rogers, Christian; Han, Fengxiang X.; Tchounwou, Paul B.

    2014-01-01

    With industrialization, great amounts of trace elements and heavy metals have been excavated and released on the surface of the earth and dissipated into the environments. Rapid screening technology for detecting major and trace elements as well as heavy metals in variety of environmental samples is most desired. The objectives of this study were to determine the detection limits, accuracy, repeatability and efficiency of a X-ray fluorescence spectrometer (Niton XRF analyzer) in comparison with the traditional analytical methods, inductively coupled plasma optical emission spectrometer (ICP-OES) and inductively coupled plasma optical emission spectrometer (ICP-MS) in screening of major and trace elements of environmental samples including estuary soils and sediments, contaminated soils, and biological samples. XRF is a fast and non-destructive method in measuring the total concentration of multi--elements simultaneously. Contrary to ICP-OES and ICP-MS, XRF analyzer is characterized by the limited preparation required for solid samples, non-destructive analysis, increased total speed and high throughout, the decreased production of hazardous waste and the low running costs as well as multi-elemental determination and portability in the fields. The current comparative study demonstrates that XRF is a good rapid non-destructive method for contaminated soils, sediments and biological samples containing higher concentrations of major and trace elements. Unfortunately, XRF does not have sensitive detection limits of most major and trace elements as ICP-OES or ICP-MS but it may serve as a rapid screening tool for locating hot spots of uncontaminated field soils and sediments. PMID:25861136

  17. Innovation

    Science.gov (United States)

    EPA frames innovation as critical to the protection of human health and the environment through initiatives such as sustainable practices, innovative research, prize competitions, innovation awards, partnerships, and community activities.

  18. Pigment particles analysis with a total reflection X-ray fluorescence spectrometer: study of influence of instrumental parameters

    Energy Technology Data Exchange (ETDEWEB)

    Coccato, Alessia; Vandenabeele, Peter [Ghent University, Department of Archaeology, Ghent (Belgium); Vekemans, Bart; Vincze, Laszlo; Moens, Luc [Ghent University, Department of Analytical Chemistry, Ghent (Belgium)

    2016-12-15

    Total reflection X-ray fluorescence (TXRF) analysis is an excellent tool to determine major, minor and trace elements in minuscule amounts of samples, making this technique very suitable for pigment analysis. Collecting minuscule amounts of pigment material from precious works of art by means of a cotton swab is a well-accepted sampling method, but poses specific challenges when TXRF is to be used for the characterization of the unknown material. (orig.)

  19. Pigment particles analysis with a total reflection X-ray fluorescence spectrometer: study of influence of instrumental parameters

    Science.gov (United States)

    Coccato, Alessia; Vekemans, Bart; Vincze, Laszlo; Moens, Luc; Vandenabeele, Peter

    2016-12-01

    Total reflection X-ray fluorescence (TXRF) analysis is an excellent tool to determine major, minor and trace elements in minuscule amounts of samples, making this technique very suitable for pigment analysis. Collecting minuscule amounts of pigment material from precious works of art by means of a cotton swab is a well-accepted sampling method, but poses specific challenges when TXRF is to be used for the characterization of the unknown material.

  20. Fluorescence of the gamma, epsilon, and delta systems of nitric oxide - Polarization and use of calculated intensities for spectrometer calibration.

    Science.gov (United States)

    Poland, H. M.; Broida, H. P.

    1971-01-01

    Results of a study in which fluorescence of the gamma system of nitric oxide was obtained by excitation from both the 2144 A line of ionized cadmium and a continuum source. Individual rotational lines of the 2144 A excited fluorescence spectrum were found to be partially polarized and to have polarizations of differ ing sign. Measured relative vibrational band intensities from line and continuum excitation were compared to calculated Franck-Condon factors. Those Franck-Condon factors based on a single potential for the two spin states of the X super pi state agreed better with measured values than those based on separate potentials for the two spin states. Calculated intensities of the v prime = 3 progression were used to calibrate the instrument response in the wavelength region from 2000 to 2500 A and were checked with measured intensities of the v prime = 0.1, and 2 progressions. Fluorescence of the epsilon and delta bands obtained with continuum lamp excitation also were compared to calculated intensities.

  1. Measurements of Bacterial Concentrations on a Millimeter Scale in Ice Cores With a Scanning Laser Fluorescence Spectrometer

    Science.gov (United States)

    Price, P.; Rohde, R. A.; Bramall, N. E.; Bay, R. C.

    2006-12-01

    We report non-destructive detection of variability on a mm depth scale in the organic content of ice cores at NICL, as determined by the fluorescence spectrum measured by a Targeted Ultraviolet Chemical Sensor (TUCS). Many of the spectra we obtained are consistent with the amino acid tryptophan, a strongly fluorescing constituent in microbes. Identification with native fluorescence of microbes is supported by previous measurements of varying microbial concentration in samples from selected regions of the GISP2 core (Tung et al., 2005; 2006) that are consistent with our observations at the same depths. Sub-mm depth resolution was achieved and structure at this scale was observed. At each depth the fluorescence emission spectrum was measured at 5 wavelengths using 20-nm narrow band filters plus a long pass channel. The spectrum of microbes was calibrated by making lab measurements of fluorescence of various species and is distinguishable from mineral dust and metals due to differences in spectral shape. In bulk ice samples from 3 depths in the GISP2 core, where a table of methane concentrations (Ed Brook, unpublished) had shown several excesses above the atmospheric contribution, Tung et al. (2005) found 10-fold excesses of microbial concentrations at 2954 m and 3036 m and a 3-fold excess at 3018 m. In the present work we found strong, rapidly varying organic signals at all three depths. At 3018 m the peak value was much stronger than that obtained by Brook and occurred in the core section below the one he studied. Since he measured methane at several-meter depth intervals, and since we found the microbial excesses to be concentrated in 0.3 m intervals, we conclude that of order 30 microbe-rich regions may be present in GISP2. The 3 microbe-rich depths found by Tung et al. (2005) were less than 90 m above the basal ice at 3041-3053 m. The large fluctuations in apparent tryptophan concentrations that we found at 2954, 3018, and 3036 m are consistent with microbe

  2. Innovation

    DEFF Research Database (Denmark)

    Nielsen, Janni; Yaganeh, Suzanne; Bloch Rasmussen, Leif

    2013-01-01

    This paper contributes to a theoretical discussion of creation of innovation with participants in, or outside, organisations. We address the creation of innovation with a complex theoretical understanding drawing on the Scandinavian and the Participatory Design tradition introducing two approaches...... to the processes of innovation. We ask if innovation can be initiated and enhanced looking at two collaborative approaches; participatory innovation (PIN) and cooperative innovation (COIN). We invite to dialogue and reflections on PIN’s conflict and creative frictions on one side and COIN’s complexity......, complementarity in diversity and the didactic scaffolding of the innovation process on the other side. Our contribution focuses on the methods and practices for facilitation of co-creating activities between different groups leading to cooperation, and innovation in thinking....

  3. Construction of a remote probe for a spectrometer using NaI(TI) detector and X-ray fluorescence by energy dispersion

    International Nuclear Information System (INIS)

    Brandão Junior, Francisco Antônio

    2014-01-01

    This research project aims the utilization of NaI(Tl) cylindrical detectors with different sensitive volumes in the Nuclear Instrumentation Laboratory (LIN) of the Department of Nuclear Engineering at UFMG (DEN-UFMG) for construction of spectrometers using the X-ray fluorescence (XRF) technique. Conical coupling devices between the crystal detectors and the photomultiplier valve (VMF) were designed and constructed using easily handled material, joined by an optical fiber cable (FO) for driving the luminescence from the detector crystal to the VFM, allowing greater flexibility and accessibility to the device using the aforementioned technique. The cable connections were adapted to the cones that have a system with adjustable convergent lens to maximize level of luminescence (input and output). The photon beam is conducted by FO from the crystal detector to the VFM. This remote probe may bring new solutions for use not only in EDXRF technique but also in other future applications using the NaI(Tl) detector. The SR was designed and built based on the FO properties to conduct the light by total reflection with minimal loss; the first SR qualitative tests were performed and the results demonstrate that the system works properly. (author)

  4. Innovative molecular-based fluorescent nanoparticles for multicolor single particle tracking in cells

    International Nuclear Information System (INIS)

    Daniel, Jonathan; Blanchard-Desce, Mireille; Godin, Antoine G; Palayret, Matthieu; Lounis, Brahim; Cognet, Laurent

    2016-01-01

    Based on an original molecular-based design, we present bright and photostable fluorescent organic nanoparticles (FONs) showing excellent colloidal stability in various aqueous environments. Complementary near-infrared emitting and green emitting FONs were prepared using a simple, fast and robust protocol. Both types of FONs could be simultaneously imaged at the single-particle level in solution as well as in biological environments using a monochromatic excitation and a dual-color fluorescence microscope. No evidence of acute cytotoxicity was found upon incubation of live cells with mixed solutions of FONs, and both types of nanoparticles were found internalized in the cells where their motion could be simultaneously tracked at video-rate up to minutes. These fluorescent organic nanoparticles open a novel non-toxic alternative to existing nanoparticles for imaging biological structures, compatible with live-cell experiments and specially fitted for multicolor single particle tracking. (paper)

  5. Innovation

    OpenAIRE

    2009-01-01

    Il s’agit du second ouvrage paru dans le cadre du projet « Innovation und Recht », financé par la Fondation Volkswagen. D’approche interdisciplinaire, celui-ci a pour ambition de dé­terminer l’impact du droit existant sur l’innovation en vue de le faire évoluer. Au regard du droit de la concurrence et de la régulation sectorielle actuels, les auteurs se consacrent aux possibilités offertes par une orientation accrue vers l’innovation, notamment dans le secteur prometteur des télécommunication...

  6. Determination of heavy metals concentrations in airborne particulates matter (APM) from Manjung district, Perak using energy dispersive X-ray fluorescence (EDXRF) spectrometer

    Science.gov (United States)

    Arshad, Nursyairah; Hamzah, Zaini; Wood, Ab. Khalik; Saat, Ahmad; Alias, Masitah

    2015-04-01

    Airborne particulates trace metals are considered as public health concern as it can enter human lungs through respiratory system. Generally, any substance that has been introduced to the atmosphere that can cause severe effects to living things and the environment is considered air pollution. Manjung, Perak is one of the development districts that is active with industrial activities. There are many industrial activities surrounding Manjung District area such as coal fired power plant, quarries and iron smelting which may contribute to the air pollution into the environment. This study was done to measure the concentrations of Hg, U, Th, K, Cu, Fe, Cr, Zn, As, Se, Pb and Cd in the Airborne Particulate Matter (APM) collected at nine locations in Manjung District area within 15 km radius towards three directions (North, North-East and South-East) in 5 km intervals. The samples were collected using mini volume air sampler with cellulose filter through total suspended particulate (TSP). The sampler was set up for eight hours with the flow rate of 5 L/min. The filter was weighed before and after sample collection using microbalance, to get the amount of APM and kept in desiccator before analyzing. The measurement was done using calibrated Energy Dispersive X-Ray Fluorescence (EDXRF) Spectrometer. The air particulate concentrations were found below the Malaysia Air Quality Guidelines for TSP (260 µg/m3). All of the metals concentrations were also lower than the guidelines set by World Health Organization (WHO), Ontario Ministry of the Environment and Argonne National Laboratory, USA NCRP (1975). From the concentrations, the enrichment factor were calculated.

  7. Innovation

    DEFF Research Database (Denmark)

    Helms, Niels Henrik

    2012-01-01

    Kravet om innovation og kreativitet er på flere måder en stor og en ny udfordring for voksenuddannelserne. Det udfordrer det didaktiske dilemma, det at vi skal gøres til kompetente og frie mennesker gennem pædagogiske handlinger, som netop pålægger os en ufrihed. – Men hvor denne ufrihed...... innovative, netop er det, vi endnu ikke kender...

  8. Innovation

    OpenAIRE

    2008-01-01

    Voilà deux approches complémentaires de la problématique de l’innovation et des pôles de compétitivité. L’innovation, facteur-clef de compétitivité, y est considérée sous deux angles. D’un côté, celui de la politique industrielle et de sa mise en œuvre à l’échelon territorial via la création de pôles de compétitivité et des partenariats institutionnels que cela implique. D’un autre côté, l’angle des systèmes nationaux d’innovation et de leur comparaison internationale ; ces systèmes sont cons...

  9. Monolithic spectrometer

    Science.gov (United States)

    Rajic, Slobodan; Egert, Charles M.; Kahl, William K.; Snyder, Jr., William B.; Evans, III, Boyd M.; Marlar, Troy A.; Cunningham, Joseph P.

    1998-01-01

    A monolithic spectrometer is disclosed for use in spectroscopy. The spectrometer is a single body of translucent material with positioned surfaces for the transmission, reflection and spectral analysis of light rays.

  10. Innovation

    DEFF Research Database (Denmark)

    Torfing, Jacob; Ricard, Lykke Margot

    2017-01-01

    Innovation i krydsfeltet mellem forskellige styringsparadigmer i offentlige organisationer. New Public Governance gør det muligt at skabe offentlig værdi på nye måder. Men NPG er ingen trylledrik, der fra den ene dag til den anden skaber balance mellem borgernes store forventninger og en trængt...

  11. Innovation

    African Journals Online (AJOL)

    ... libraries as support for the reading intervention is also an important part of the project. The focus of this article is on the use of family literacy workshops to introduce the reading programme and the fledgling school libraries to parents and the potential role of the school library in supporting reading activities. Innovation Vol.

  12. Innovation

    African Journals Online (AJOL)

    In order to gain experience in scanning of diverse media, projects have deliberately been kept small. It has been found that management of scanned images is as important as the process of scanning. Adequate planning, correct storage procedures and accurate metadata are essential to the success of a project. Innovation ...

  13. Innovation

    African Journals Online (AJOL)

    The purpose of Innovation journal of appropriate librarianship and information work in Southern Africa is to publish material on libraries, information supply and other related matters in South and Southern Africa. Vol 45 (2012). DOWNLOAD FULL TEXT Open Access DOWNLOAD FULL TEXT Subscription or Fee Access ...

  14. INNOVATION

    DEFF Research Database (Denmark)

    Helms, Niels Henrik

    2012-01-01

    Kravet om innovation og kreativitet er på flere måder en stor og en ny udfordring for voksenuddannelserne. Det udfordrer det didaktiske dilemma, det at vi skal gøres til kompetente og frie mennesker gennem pædagogiske handlinger, som netop pålægger os en ufrihed. – Men hvor denne ufrihed tidligere...... kunne begrundes med, at skolen eller uddannelsen vidste bedre, så er det ikke længere tilfældet. Skolen skal sørge for, at vi lærer noget – og ikke noget andet. Men det kan ikke længere med bestemthed afgøres, hvad det er vi skal lære i skolen, fordi det nye, det kreative og ikke mindst innovative...

  15. Innovation

    OpenAIRE

    2012-01-01

    Présenté par FutuRIS, plate-forme prospective sur la recherche, l’innovation et la société animée par l’Association Nationale de la Recherche et de la Technologie, ce volume livre un panorama du système français de recherche et d’innovation dans son environnement européen. Sont abordés dans une première partie les champs décisionnels concernés, les politiques nationales menées en matière de R&D, les relations entre enseignement supérieur et recherche et l’Espace européen de la recherche à l’h...

  16. Compact fluorescent lamps, innovation for electricity saving; Lamparas fluorescentes compactas, innovacion para el ahorro de electricidad

    Energy Technology Data Exchange (ETDEWEB)

    Rivera, Fernando [Fideicomiso para el Ahorro de Energia Electrica (Mexico); Camacho P, Wendolin E; Villalobos Alarcon, German [Phillips Lighting Mexico (Mexico)

    2007-01-15

    An extremely important resource is electricity because it has provided illumination for homes, buildings and cities in the absence of natural light. Therefore, the human being is considering to save this valuable resource by using sophisticated light bulbs. At the end of the 70's the compact fluorescent lamps appeared. In this article we can disclose the advantages and disadvantages of this technology, and how some years later of its invention, those lamps satisfied the client expectations, due to its cost, electricity saving, longer lifetime, use possibilities, and technological improvements. We can also know how Federal Electricity Commission (CFE) and The Trust Fund for Electric Energy Savings (FIDE) supported a project to favor these lamps to be in the Mexican market. [Spanish] La electricidad es un recurso de suma importancia porque ha contribuido a la iluminacion de casas, edificios y ciudades, ante la ausencia de luz natural, es por ello que se ha buscado ahorrar este recurso tan preciado con el uso de lamparas sofisticadas. Una tecnologia que aparecio a finales de los anos 70 fueron las lamparas fluorescentes compactas. En este articulo encontramos sus ventajas y desventajas, y como despues de algunos anos de su creacion comenzaron a llenar las expectativas del cliente gracias a su costo, ahorro de electricidad, mayor tiempo de vida, posibilidades de aplicacion y mejoras tecnologicas. Asi mismo podemos conocer, el proyecto que se hizo para que esta tecnologia entrara al mercado mexicano, con el apoyo de la Comision Federal de Electricidad (CFE) y del Fideicomiso para el Ahorro de Energia Electrica (FIDE).

  17. Clinical Application of an Innovative Multiplex-Fluorescent-Labeled STRs Assay for Prader-Willi Syndrome and Angelman Syndrome.

    Science.gov (United States)

    Zhang, Kaihui; Liu, Shu; Feng, Bing; Yang, Yali; Zhang, Haiyan; Dong, Rui; Liu, Yi; Gai, Zhongtao

    2016-01-01

    Prader-Willi syndrome (PWS) and Angelman syndrome (AS) are two clinically distinct neurodevelopmental disorders caused by absence of paternally or maternally expressed imprinted genes on chr15q11.2-q13.3. Three mechanisms are known to be involved in the pathogenesis: microdeletions, uniparental disomy (UPD) and imprinting defects. Both disorders are difficult to be definitely diagnosed at early age if no available molecular cytogenetic tests. In this study, we identified 5 AS patients with the maternal deletion and 26 PWS patients with paternal deletion on chr15q11-q13 by using an innovative multiplex-fluorescent-labeled short tandem repeats (STRs) assay based on linkage analysis, and validated by the methylation-specific PCR and array comparative genomic hybridization techniques. More interesting, one of these PWS patients was confirmed as maternal uniparental isodisomy by the STR linkage analysis. The phenotypic and genotypic characteristics of these individuals were also presented. Our results indicate that the new linkage analysis is much faster and easier for large-scale screening deletion and uniparental disomy, thus providing a valuable method for early diagnosis of PWS/AS patients, which is critical for genetic diagnosis, management and improvement of prognosis.

  18. Innovation

    OpenAIRE

    2011-01-01

    Cette publication biennale, dont voici le septième volume, recense les tendances et les grandes orientations scientifiques, technologiques et industrielles, dans l’ensemble de la zone OCDE, ainsi que dans les grandes économies non membres. Outre les notes par pays en matière de recherche et d’innovation, le rapport présente l’évolution des politiques nationales et leur évaluation en termes de « dosage ». Comme l’OCDE célèbre cette année son 50e anniversaire, cette édition 2010 comporte égalem...

  19. Correlation spectrometer

    Science.gov (United States)

    Sinclair, Michael B [Albuquerque, NM; Pfeifer, Kent B [Los Lunas, NM; Flemming, Jeb H [Albuquerque, NM; Jones, Gary D [Tijeras, NM; Tigges, Chris P [Albuquerque, NM

    2010-04-13

    A correlation spectrometer can detect a large number of gaseous compounds, or chemical species, with a species-specific mask wheel. In this mode, the spectrometer is optimized for the direct measurement of individual target compounds. Additionally, the spectrometer can measure the transmission spectrum from a given sample of gas. In this mode, infrared light is passed through a gas sample and the infrared transmission signature of the gasses present is recorded and measured using Hadamard encoding techniques. The spectrometer can detect the transmission or emission spectra in any system where multiple species are present in a generally known volume.

  20. Innovation

    OpenAIRE

    2008-01-01

    A l’heure où le gouvernement fédéral accroît ses dépenses de R&D de 7 % pour réaliser l’objectif de Lisbonne des 3 % de R&D dans le PIB à l’horizon 2010, cette étude publiée par la Fondation Hans Böckler du DGB tombe à point nommé. Ses auteurs passent en revue pour les évaluer les politiques d’innovation technologique menée par 9 Länder, dont bien entendu la Bavière et le Bade-Wurtemberg, mais aussi la Saxe ou la Sarre. (ib)

  1. Multidimensional spectrometer

    Science.gov (United States)

    Zanni, Martin Thomas; Damrauer, Niels H.

    2010-07-20

    A multidimensional spectrometer for the infrared, visible, and ultraviolet regions of the electromagnetic spectrum, and a method for making multidimensional spectroscopic measurements in the infrared, visible, and ultraviolet regions of the electromagnetic spectrum. The multidimensional spectrometer facilitates measurements of inter- and intra-molecular interactions.

  2. Mass spectrometers

    International Nuclear Information System (INIS)

    Manojlov, V.E.; Nedelin, P.N.; Lukichev, A.N.; Sapozhkov, L.K.; Turubarov, V.I.

    1980-01-01

    Mass spectrometers of different types are suggested to use for qualitative and quantitative analyses of gas. The operation principles of static and dynamic mass spectrometer are studied. In static mass spectrometers mass separation of ions is performed by changing the value of accelerating voltage in the ion source when retaining the magnetic field intensity. Such devices are stationary. The device mass is conditioned by the magnet mass. Mass separation in dynamic mass spectrometers is dependent on the degree of energy increment of ions in HF-electric fields. Radio frequency mass spectrometers are used with advantage for studying upper layers of an atmosphere and are installed on radiosondes and satellites. The main technical characteristics of the MX-1330 mass spectrometer, the basis of which is the analyzer with 180 deg deviation of an ion beam in the field of permanent magnet, are presented. The device is intended for controlling the environment and permits to analyze gases with a molecular mass up to 450 using various systems of gas filling. The error of determination of molecular substance is not greater than +-3 %; the magnetic field intensity constitutes 4.8x10 5 A/m; the supply voltage is 380/220 V; the total power is 5.0 kVA [ru

  3. A novel vacuum spectrometer for total reflection x-ray fluorescence analysis with two exchangeable low power x-ray sources for the analysis of low, medium, and high Z elements in sequence

    Energy Technology Data Exchange (ETDEWEB)

    Wobrauschek, P., E-mail: wobi@ati.ac.at; Prost, J.; Ingerle, D.; Kregsamer, P.; Streli, C. [Atominstitut, TU Wien, Stadionallee 2, 1020 Vienna (Austria); Misra, N. L. [Fuel Chemistry Division, Bhabha Atomic Research Centre (BARC), Mumbai 400085 (India)

    2015-08-15

    The extension of the detectable elemental range with Total Reflection X-ray Fluorescence (TXRF) analysis is a challenging task. In this paper, it is demonstrated how a TXRF spectrometer is modified to analyze elements from carbon to uranium. Based on the existing design of a vacuum TXRF spectrometer with a 12 specimen sample changer, the following components were renewed: the silicon drift detector with 20 mm{sup 2} active area and having a special ultra-thin polymer window allowing the detection of elements from carbon upwards. Two exchangeable X-ray sources guarantee the efficient excitation of both low and high Z elements. These X-ray sources were two light-weighted easily mountable 35 W air-cooled low-power tubes with Cr and Rh anodes, respectively. The air cooled tubes and the Peltier-cooled detector allowed to construct a transportable tabletop spectrometer with compact dimensions, as neither liquid nitrogen cooling for the detector nor a water cooling circuit and a bulky high voltage generator for the X-ray tubes are required. Due to the excellent background conditions as a result of the TXRF geometry, detection limits of 150 ng for C, 12 ng for F, and 3.3 ng for Na have been obtained using Cr excitation in vacuum. For Rh excitation, the detection limits of 90 pg could be achieved for Sr. Taking 10 to 20 μl of sample volume, extrapolated detection limits in the ng/g (ppb) range are resulting in terms of concentration.

  4. A novel vacuum spectrometer for total reflection x-ray fluorescence analysis with two exchangeable low power x-ray sources for the analysis of low, medium, and high Z elements in sequence

    Science.gov (United States)

    Wobrauschek, P.; Prost, J.; Ingerle, D.; Kregsamer, P.; Misra, N. L.; Streli, C.

    2015-08-01

    The extension of the detectable elemental range with Total Reflection X-ray Fluorescence (TXRF) analysis is a challenging task. In this paper, it is demonstrated how a TXRF spectrometer is modified to analyze elements from carbon to uranium. Based on the existing design of a vacuum TXRF spectrometer with a 12 specimen sample changer, the following components were renewed: the silicon drift detector with 20 mm2 active area and having a special ultra-thin polymer window allowing the detection of elements from carbon upwards. Two exchangeable X-ray sources guarantee the efficient excitation of both low and high Z elements. These X-ray sources were two light-weighted easily mountable 35 W air-cooled low-power tubes with Cr and Rh anodes, respectively. The air cooled tubes and the Peltier-cooled detector allowed to construct a transportable tabletop spectrometer with compact dimensions, as neither liquid nitrogen cooling for the detector nor a water cooling circuit and a bulky high voltage generator for the X-ray tubes are required. Due to the excellent background conditions as a result of the TXRF geometry, detection limits of 150 ng for C, 12 ng for F, and 3.3 ng for Na have been obtained using Cr excitation in vacuum. For Rh excitation, the detection limits of 90 pg could be achieved for Sr. Taking 10 to 20 μl of sample volume, extrapolated detection limits in the ng/g (ppb) range are resulting in terms of concentration.

  5. A novel vacuum spectrometer for total reflection x-ray fluorescence analysis with two exchangeable low power x-ray sources for the analysis of low, medium, and high Z elements in sequence.

    Science.gov (United States)

    Wobrauschek, P; Prost, J; Ingerle, D; Kregsamer, P; Misra, N L; Streli, C

    2015-08-01

    The extension of the detectable elemental range with Total Reflection X-ray Fluorescence (TXRF) analysis is a challenging task. In this paper, it is demonstrated how a TXRF spectrometer is modified to analyze elements from carbon to uranium. Based on the existing design of a vacuum TXRF spectrometer with a 12 specimen sample changer, the following components were renewed: the silicon drift detector with 20 mm(2) active area and having a special ultra-thin polymer window allowing the detection of elements from carbon upwards. Two exchangeable X-ray sources guarantee the efficient excitation of both low and high Z elements. These X-ray sources were two light-weighted easily mountable 35 W air-cooled low-power tubes with Cr and Rh anodes, respectively. The air cooled tubes and the Peltier-cooled detector allowed to construct a transportable tabletop spectrometer with compact dimensions, as neither liquid nitrogen cooling for the detector nor a water cooling circuit and a bulky high voltage generator for the X-ray tubes are required. Due to the excellent background conditions as a result of the TXRF geometry, detection limits of 150 ng for C, 12 ng for F, and 3.3 ng for Na have been obtained using Cr excitation in vacuum. For Rh excitation, the detection limits of 90 pg could be achieved for Sr. Taking 10 to 20 μl of sample volume, extrapolated detection limits in the ng/g (ppb) range are resulting in terms of concentration.

  6. Non-destructive in situ study of “Mad Meg” by Pieter Bruegel the Elder using mobile X-ray fluorescence, X-ray diffraction and Raman spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Van de Voorde, Lien, E-mail: lien.vandevoorde@ugent.be [Ghent University, Department of Analytical Chemistry, X-ray Microspectroscopy and Imaging Research Group, Krijgslaan 281 S12, B-9000 Gent (Belgium); Van Pevenage, Jolien [Ghent University, Department of Analytical Chemistry, Raman Spectroscopy Research Group, Krijgslaan 281 S12, B-9000 Gent (Belgium); De Langhe, Kaat [Ghent University, Department of Archaeology, Archaeometry Research Group, Sint-Pietersnieuwstraat 35, B-9000 Gent (Belgium); De Wolf, Robin; Vekemans, Bart; Vincze, Laszlo [Ghent University, Department of Analytical Chemistry, X-ray Microspectroscopy and Imaging Research Group, Krijgslaan 281 S12, B-9000 Gent (Belgium); Vandenabeele, Peter [Ghent University, Department of Archaeology, Archaeometry Research Group, Sint-Pietersnieuwstraat 35, B-9000 Gent (Belgium); Martens, Maximiliaan P.J. [Ghent University, Department of Art, Music and Theatre Sciences, Blandijnberg 2, B-9000 Gent (Belgium)

    2014-07-01

    “Mad Meg”, a figure of Flemish folklore, is the subject of a famous oil-on-panel painting by the Flemish renaissance artist Pieter Bruegel the Elder, exhibited in the Museum Mayer van den Bergh (Antwerp, Belgium). This article reports on the in situ chemical characterization of this masterpiece by using currently available state-of-the-art portable analytical instruments. The applied non-destructive analytical approach involved the use of a) handheld X-ray fluorescence instrumentation for retrieving elemental information and b) portable X-ray fluorescence/X-ray diffraction instrumentation and laser-based Raman spectrometers for obtaining structural/molecular information. Next to material characterization of the used pigments and of the different preparation layers of the painting, also the verification of two important historical iconographic hypotheses is performed concerning the economic way of painting by Brueghel, and whether or not he used blue smalt pigment for painting the boat that appears towards the top of the painting. The pigments identified are smalt pigment (65% SiO{sub 2} + 15% K{sub 2}O + 10% CoO + 5% Al{sub 2}O{sub 3}) for the blue color present in all blue areas of the painting, probably copper resinate for the green colors, vermillion (HgS) as red pigment and lead white is used to form different colors. The comparison of blue pigments used on different areas of the painting gives no differences in the elemental fingerprint which confirms the existing hypothesis concerning the economic painting method by Bruegel. - Highlights: • In situ, non-destructive investigation of a famous painting by Pieter Bruegel. • Use of a new, commercial available, portable XRF/XRD instrumentation. • Multi-methodological approach: make also use of a mobile Raman spectrometer. • Used pigments and different preparation layers of the painting are characterized. • The verification of two important historical iconographic hypotheses are performed.

  7. Archaeochemical study of the ancient Egyptian glass from the collection of the Ancient Egyptian Museum, Tokyo using a newly developed portable X-ray fluorescence spectrometer equipped with a CMOS camera

    International Nuclear Information System (INIS)

    Kikugawa, Tadashi; Abe, Yoshinari; Nakai, Izumi; Sanada, Takashi

    2009-01-01

    An improved version of the portable X-ray fluorescence spectrometer, OURSTEX FA-IV was manufactured; its weight was reduced to 16 kg. and a CMOS camera was installed for pinpoint analysis of the artifacts. By applying this spectrometer to element analysis of ancient Egyptian glass in the collection of the Ancient Egyptian Museum, Shibuya, Tokyo, copper and cobalt were identified in the blue colorant of the glasses. A combination with a portable X-ray powder diffractometer was also examined, and disclosed lead antimonate Pb 2 Sb 2 O 7 and lead stannate PbSnO 3 as the yellow colorants and calcium antimonite Ca 2 Sb 2 O 7 as the white colorant of the glass. The results provide new examples of historical use of cobalt alum in the Roman period (A.D.2 C.) which was believed to be used only in the New Kingdom (B.C.14-11 C.), and that of lead stannate PbSnO 3 in the A.D.2 C, which was thought to be used after A.D.4 C. Further, XRF imaging utilizing laboratory X-ray microscope or synchrotron radiation X-ray microbeam was also applied to reveal colorants of yellow, blue, white and black colors used in complex archaeological patterns. (author)

  8. ICARUS+NESSiE: A proposal for short baseline neutrino anomalies with innovative LAr imaging detectors coupled with large muon spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Gibin, D., E-mail: daniele.gibin@pd.infn.it

    2013-04-15

    The proposal for an experimental search for sterile neutrinos beyond the Standard Model with a new CERN-SPS neutrino beam is presented. The experiment is based on two identical LAr-TPC's followed by magnetized spectrometers, observing the electron and muon neutrino events at 1600 and 300 m from the proton target. This project will exploit the ICARUS T600, moved from LNGS to the CERN “Far” position. An additional 1/4 of the T600 detector will be constructed and located in the “Near” position. Two spectrometers will be placed downstream of the two LAr-TPC detectors to greatly complement the physics capabilities. Comparing the two detectors, in absence of oscillations, all cross sections and experimental biases cancel out. Any difference of the event distributions at the locations of the two detectors might be attributed to the possible existence of ν-oscillations, presumably due to additional neutrinos with a mixing angle sin{sup 2}(2θ{sub new}) and a larger mass difference Δm{sub new}{sup 2}. The superior quality of the LAr imaging TPC, in particular its unique electron-π{sub 0} discrimination allows full rejection of backgrounds and offers a lossless ν{sub e} detection capability. The determination of the muon charge with the spectrometers allows the full separation of ν{sub μ} from anti-ν{sub μ} and therefore controlling systematics from muon mis-identification largely at high momenta.

  9. ICARUS+NESSiE: A proposal for short baseline neutrino anomalies with innovative LAr imaging detectors coupled with large muon spectrometers

    Science.gov (United States)

    Gibin, D.

    2013-04-01

    The proposal for an experimental search for sterile neutrinos beyond the Standard Model with a new CERN-SPS neutrino beam is presented. The experiment is based on two identical LAr-TPC's followed by magnetized spectrometers, observing the electron and muon neutrino events at 1600 and 300 m from the proton target. This project will exploit the ICARUS T600, moved from LNGS to the CERN "Far" position. An additional 1/4 of the T600 detector will be constructed and located in the "Near" position. Two spectrometers will be placed downstream of the two LAr-TPC detectors to greatly complement the physics capabilities. Comparing the two detectors, in absence of oscillations, all cross sections and experimental biases cancel out. Any difference of the event distributions at the locations of the two detectors might be attributed to the possible existence of ν-oscillations, presumably due to additional neutrinos with a mixing angle sin2(2θ) and a larger mass difference Δmnew2. The superior quality of the LAr imaging TPC, in particular its unique electron-π0 discrimination allows full rejection of backgrounds and offers a lossless νe detection capability. The determination of the muon charge with the spectrometers allows the full separation of νμ from anti-νμ and therefore controlling systematics from muon mis-identification largely at high momenta.

  10. Low Power Mass Spectrometer employing TOF Project

    Data.gov (United States)

    National Aeronautics and Space Administration — A low power Mass Spectrometer employing multiple time of flight circuits for parallel processing is possible with a new innovation in design of the Time of flight...

  11. Spectrometer gun

    Science.gov (United States)

    Waechter, David A.; Wolf, Michael A.; Umbarger, C. John

    1985-01-01

    A hand-holdable, battery-operated, microprocessor-based spectrometer gun includes a low-power matrix display and sufficient memory to permit both real-time observation and extended analysis of detected radiation pulses. Universality of the incorporated signal processing circuitry permits operation with various detectors having differing pulse detection and sensitivity parameters.

  12. Determination of trace elements in mine soil samples using portable X-ray fluorescence spectrometer: A comparative study with ICP-OES

    Directory of Open Access Journals (Sweden)

    Hamdi Sahraoui

    2016-08-01

    Full Text Available Lead (Pb, Zinc (Zn and Cadmium (Cd levels on soils surrounding of Lakhouat mine (North-West of Tunisia were measured. The total concentration of these elements in the soil samples was determined by portable X-ray fluorescence (XRF in situ and compared to the traditional digestion method using inductively coupled-plasma optical emission spectroscopy (ICP-OES. Statistical analyses were performed to determine if significant differences existed between the instrumental techniques, which included simple correlations by the regression lines and t-test for mean comparison. The statistical analysis demonstrated that no statistically significant differences were observed for the Pb concentrations; however, for the Zn and Cd concentrations, t-test showed significant differences between the inst

  13. The Spectrometer

    Science.gov (United States)

    Greenslade, Thomas B., Jr.

    2012-01-01

    In the fall of 1999 I was shown an Ocean Optics spectrometer-in-the-computer at St. Patricks College at Maynooth, Ireland, and thought that I had seen heaven. Of course, it could not resolve the sodium D-lines (I had done that many years before with a homemade wire diffraction grating), and I began to realize that inside was some familiar old…

  14. A Review of the Handheld X-Ray Fluorescence Spectrometer as a Tool for Field Geologic Investigations on Earth and in Planetary Surface Exploration

    Science.gov (United States)

    Young, Kelsey E.; Evans, Cynthia A.; Hodges, Kip V.; Bleacher, Jacob E.; Graff, Trevor G.

    2016-01-01

    X-ray fluorescence (XRF) spectroscopy is a well-established and commonly used technique in obtaining diagnostic compositional data on geological samples. Recently, developments in X-ray tube and detector technologies have resulted in miniaturized, field-portable instruments that enable new applications both in and out of standard laboratory settings. These applications, however, have not been extensively applied to geologic field campaigns. This study investigates the feasibility of using developing handheld XRF (hXRF) technology to enhance terrestrial field geology, with potential applications in planetary surface exploration missions. We demonstrate that the hXRF is quite stable, providing reliable and accurate data continuously over a several year period. Additionally, sample preparation is proved to have a marked effect on the strategy for collecting and assimilating hXRF data. While the hXRF is capable of obtaining data that are comparable to laboratory XRF analysis for several geologically-important elements (such as Si, Ca, Ti, and K), the instrument is unable to detect other elements (such as Mg and Na) reliably. While this limits the use of the hXRF, especially when compared to laboratory XRF techniques, the hXRF is still capable of providing the field user with significantly improved contextual awareness of a field site, and more work is needed to fully evaluate the potential of this instrument in more complex geologic environments.

  15. MASS SPECTROMETER

    Science.gov (United States)

    White, F.A.

    1960-08-23

    A mass spectrometer is designed with a first adjustable magnetic field for resolving an ion beam into beams of selected masses, a second adjustable magnetic field for further resolving the ion beam from the first field into beams of selected masses, a thin foil disposed in the path of the beam between the first and second magnets to dissociate molecular ions incident thereon, an electrostatic field for further resolving the ion beam from the second field into beams of selected masses, and a detector disposed adjacent to the electrostatic field to receive the ion beam.

  16. Quantitative analysis of heavy metals in automotive brake linings: a comparison between wet-chemistry based analysis and in-situ screening with a handheld X-ray fluorescence spectrometer.

    Science.gov (United States)

    Figi, R; Nagel, O; Tuchschmid, M; Lienemann, P; Gfeller, U; Bukowiecki, N

    2010-08-31

    Two extraction procedures for ecologically relevant elements present in automotive brake linings (Sb, Bi, Pb, Cd, Cr (total), Co, Cu, Mo, Ni, Sr, V, Zn, Sn) were developed and validated, applying a high pressure asher (HPA-S) and microwave extraction, respectively. Both of these methods allowed for the quantitative analysis of the extracted elements by inductively coupled plasma optical emission spectrometry (ICP-OES). The results were compared to measurements using a handheld energy-dispersive X-ray fluorescence spectrometer (ED-XRF), being in discussion by regulating agencies as in-situ screening tool for brake pads. The comparison indicates that the handheld ED-XRF analysis is basically an efficient screening tool for a reliable assessment of trace metal contents in automotive brake pads with respect to legal standards. While a quantitative determination of elements like Cd, Co, Cr, Mn, Mo, Ni, Pb and Sb was achievable, other elements (V, Cu, Bi, Zn, Sn and Sr) could only be determined qualitatively due to the special matrix characteristics of brake pads. 2010 Elsevier B.V. All rights reserved.

  17. Wavelength-dispersive total-reflection X-ray fluorescence with an efficient Johansson spectrometer and an undulator X-ray source: detection of 10-16 g-level trace metals.

    Science.gov (United States)

    Sakurai, Kenji; Eba, Hiromi; Inoue, Katsuaki; Yagi, Naoto

    2002-09-01

    The present paper reports significant enhancement of the detection power for total-reflection X-ray fluorescence (TXRF). The employment of an efficient wavelength-dispersive spectrometer rather than a conventional Si(Li) detector, as well as the use of a quasi-monochromatic undulator X-ray source, completely changed the quality of X-ray florescence spectra. The energy resolution is 20 times better, which effectively contributes to reducing the low-energy tail of the scattering background and to separating neighboring X-ray florescence peaks. Another advantage is its capability with respect to high-counting-rate measurements, which ensure the detection of weak signals from trace materials. The absolute and relative detection limit for nickel are 3.1 x 10(-16) g and 3.1 ppt (pg/g) for a 0.1-microL droplet of pure water, respectively, which is nearly 50 times better than the current best data achieved by conventional energy-dispersive TXRF using a Si(Li) detector system.

  18. Axis Spectrometer

    International Nuclear Information System (INIS)

    Park, Sungil

    2006-01-01

    The Cold Neutron Research Facility (CNRF) project carried out by Korea Atomic Energy Research Institute (KAERI) is an effort to bring cold neutron instrumentation to Korea's only large scale research reactor, HANARO, located in Daejeon. As part of the CNRF project, a cold neutron triple-axis spectrometer (Cold-TAS) is being developed along with other five: 40 m long and 12 m long small angle neutron scattering instruments (40m-SANS and 12m-SANS), disk-chopper time-of-flight spectrometer (DC-ToF), Bio- Reflectometer (Bio-REF) and the reflectometer with vertical sample geometry (REF-V). For those cold neutron instruments, the performance of an individual instrument depends not only on its design but also on the guide that feeds cold neutrons to the instrument. Therefore, the quality of the neutron flux at an instrument position has to be checked with the specification of the instrument. As for the Cold-TAS, since the instrument requires a tall beam and a high flux of short wavelength neutrons, it was tentatively decided that it would use the cold guide 4 (CG4). The detailed specification of the guide is listed. Checking the neutron flux of the guide at the instrument position is the obvious next step

  19. Introducing the Precision Isotope Ratio Mass Spectrometer: Novel Innovations in Multi-Collector Arrays for Isotopologues and Isotopomers in Organic Molecule Gas Analysis

    Science.gov (United States)

    Kasson, A.

    2016-12-01

    In January 2016, elementar Analysensysteme, GmbH (Germany), in conjunction with their daughter company, Isoprime Ltd. (United Kingdom) released the Precision isotope ratio mass spectrometer. The Precision is the newest light element IRMS on the market and adds some unique hardware and software functionalities to the basic core of stable isotopic research previously unseen. Although this system is designed to make the typical bulk and compound specific measurements that functioning stable isotope laboratories have been accustomed to, it has been designed to make complicated measurements of isotopologues, isotopomers and clumped isotopes much more turnkey and user friendly. Here we focus on some datasets that have been collected from three different beta test sites and highlight the functional use of the new hardware in conjunction with ionOS operating software. As part of those highlights, the improved precision, accuracy and ion optics of the Precision IRMS will be demonstrated. In addition, we intend to show that the reprocessing functions on the ionOS software package are not only beneficial to users of just the Precision IRMS, but to the entire stable isotope community as a whole.

  20. Fourier Transform Spectrometer

    Data.gov (United States)

    National Aeronautics and Space Administration — The Fourier Transform Spectrometer project demonstrates the efficacy of a miniaturized spectrometer for flight applications.A spectrometer is an instrument used to...

  1. Silicon spectrometer with a Peltier refrigerator

    International Nuclear Information System (INIS)

    Belcarz, E.; Chwaszczewska, J.; Hahn, G.; Nowicki, W.; Sawicka, B.; Skoczek, K.; Slapa, M.; Szymczak, M.

    1974-01-01

    This paper describes a spectrometer with a Si(Li) detector cooled by a Peltier refrigerator. The spectrometer is able to analyse samples of practically all most frequently encountered emitters of alpha, beta and low energy gamma radiation. The energy resolution were about 1.3-1.5 keV for 14 keV gamma radiation. The system can also operate in field conditions in the fluorescence analysis. (author)

  2. Smartphone Spectrometers

    Science.gov (United States)

    Willmott, Jon R.; Mims, Forrest M.; Parisi, Alfio V.

    2018-01-01

    Smartphones are playing an increasing role in the sciences, owing to the ubiquitous proliferation of these devices, their relatively low cost, increasing processing power and their suitability for integrated data acquisition and processing in a ‘lab in a phone’ capacity. There is furthermore the potential to deploy these units as nodes within Internet of Things architectures, enabling massive networked data capture. Hitherto, considerable attention has been focused on imaging applications of these devices. However, within just the last few years, another possibility has emerged: to use smartphones as a means of capturing spectra, mostly by coupling various classes of fore-optics to these units with data capture achieved using the smartphone camera. These highly novel approaches have the potential to become widely adopted across a broad range of scientific e.g., biomedical, chemical and agricultural application areas. In this review, we detail the exciting recent development of smartphone spectrometer hardware, in addition to covering applications to which these units have been deployed, hitherto. The paper also points forward to the potentially highly influential impacts that such units could have on the sciences in the coming decades. PMID:29342899

  3. Smartphone Spectrometers

    Directory of Open Access Journals (Sweden)

    Andrew J.S. McGonigle

    2018-01-01

    Full Text Available Smartphones are playing an increasing role in the sciences, owing to the ubiquitous proliferation of these devices, their relatively low cost, increasing processing power and their suitability for integrated data acquisition and processing in a ‘lab in a phone’ capacity. There is furthermore the potential to deploy these units as nodes within Internet of Things architectures, enabling massive networked data capture. Hitherto, considerable attention has been focused on imaging applications of these devices. However, within just the last few years, another possibility has emerged: to use smartphones as a means of capturing spectra, mostly by coupling various classes of fore-optics to these units with data capture achieved using the smartphone camera. These highly novel approaches have the potential to become widely adopted across a broad range of scientific e.g., biomedical, chemical and agricultural application areas. In this review, we detail the exciting recent development of smartphone spectrometer hardware, in addition to covering applications to which these units have been deployed, hitherto. The paper also points forward to the potentially highly influential impacts that such units could have on the sciences in the coming decades.

  4. Smartphone Spectrometers.

    Science.gov (United States)

    McGonigle, Andrew J S; Wilkes, Thomas C; Pering, Tom D; Willmott, Jon R; Cook, Joseph M; Mims, Forrest M; Parisi, Alfio V

    2018-01-14

    Smartphones are playing an increasing role in the sciences, owing to the ubiquitous proliferation of these devices, their relatively low cost, increasing processing power and their suitability for integrated data acquisition and processing in a 'lab in a phone' capacity. There is furthermore the potential to deploy these units as nodes within Internet of Things architectures, enabling massive networked data capture. Hitherto, considerable attention has been focused on imaging applications of these devices. However, within just the last few years, another possibility has emerged: to use smartphones as a means of capturing spectra, mostly by coupling various classes of fore-optics to these units with data capture achieved using the smartphone camera. These highly novel approaches have the potential to become widely adopted across a broad range of scientific e.g., biomedical, chemical and agricultural application areas. In this review, we detail the exciting recent development of smartphone spectrometer hardware, in addition to covering applications to which these units have been deployed, hitherto. The paper also points forward to the potentially highly influential impacts that such units could have on the sciences in the coming decades.

  5. Spectrometer for cluster ion beam induced luminescence

    Energy Technology Data Exchange (ETDEWEB)

    Ryuto, H., E-mail: ryuto@kuee.kyoto-u.ac.jp; Sakata, A.; Takeuchi, M.; Takaoka, G. H. [Photonics and Electronics Science and Engineering Center, Kyoto University, Kyoto 615-8510 (Japan); Musumeci, F. [Department of Physics and Astronomy, Catania University, Catania 95123 (Italy); INFN Laboratori Nazionali del Sud, Catania 95123 (Italy)

    2015-02-15

    A spectrometer to detect the ultra-weak luminescence originated by the collision of cluster ions on the surfaces of solid materials was constructed. This spectrometer consists of 11 photomultipliers with band-pass interference filters that can detect the luminescence within the wavelength ranging from 300 to 700 nm and of a photomultiplier without filter. The calibration of the detection system was performed using the photons emitted from a strontium aluminate fluorescent tape and from a high temperature tungsten filament. Preliminary measurements show the ability of this spectrometer to detect the cluster ion beam induced luminescence.

  6. Milli X-Ray Fluorescence Spectrometer

    Data.gov (United States)

    Federal Laboratory Consortium — The Eagle III Micro XRF unit is similar to a traditional XRF unit, with the primary difference being that the X-rays are focused by a polycapillary optic into a spot...

  7. Remote UV Fluorescence Lifetime Spectrometer, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — In-situ studies of the rocks, minerals, and soil on the Moon's surface provide a wealth of information during field geology and the mining phase for planetary...

  8. Dye laser spectrometer for the analysis of pulsed vacuum arcs

    International Nuclear Information System (INIS)

    Hargis, P.J. Jr.; Robertson, M.M.

    1975-01-01

    A pulsed dye laser spectrometer which is used to obtain detailed single shot spectroscopic measurements of the plasma in a pulsed vacuum arc was developed. The capabilities of this spectrometer are indicated by the detection of laser induced fluorescence signals from 10 6 neutral Ti atoms in the plasma of a pulsed vacuum arc with a Ti anode. (U.S.)

  9. Compact, Dual Channel, Mid-IR Laser Spectrometer Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The Small Business Innovative Research Phase I proposal seeks to develop a dual channel, compact mid-infrared laser spectrometer for planetary atmosphere...

  10. Compact, Dual Channel, Mid-IR Laser Spectrometer Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The Small Business Innovative Research Phase II proposal seeks to develop a dual channel, compact mid-infrared laser spectrometer for planetary atmosphere...

  11. Triple-axis spectrometer

    International Nuclear Information System (INIS)

    Toeroek, Gy.

    2001-01-01

    A triple-axis spectrometer has been designed for structural and dynamical studies of condensed matter. Because of the limited number of other operational equipment the triple axis spectrometer was used in a multi purpose regime, e.g. high resolution diffractometry, strain analysis, reflectometry, quasielastic and inelastic scattering. A polarization setup was also tested on this spectrometer. (R.P.)

  12. Optimization of time-correlated single photon counting spectrometer

    International Nuclear Information System (INIS)

    Zhang Xiufeng; Du Haiying; Sun Jinsheng

    2011-01-01

    The paper proposes a performance improving scheme for the conventional time-correlated single photon counting spectrometer and develops a high speed data acquisition card based on PCI bus and FPGA technologies. The card is used to replace the multi-channel analyzer to improve the capability and decrease the volume of the spectrometer. The process of operation is introduced along with the integration of the spectrometer system. Many standard samples are measured. The experimental results show that the sensitivity of the spectrometer is single photon counting, and the time resolution of fluorescence lifetime measurement can be picosecond level. The instrument could measure the time-resolved spectroscopy. (authors)

  13. Spherical grating spectrometers

    Science.gov (United States)

    O'Donoghue, Darragh; Clemens, J. Christopher

    2014-07-01

    We describe designs for spectrometers employing convex dispersers. The Offner spectrometer was the first such instrument; it has almost exclusively been employed on satellite platforms, and has had little impact on ground-based instruments. We have learned how to fabricate curved Volume Phase Holographic (VPH) gratings and, in contrast to the planar gratings of traditional spectrometers, describe how such devices can be used in optical/infrared spectrometers designed specifically for curved diffraction gratings. Volume Phase Holographic gratings are highly efficient compared to conventional surface relief gratings; they have become the disperser of choice in optical / NIR spectrometers. The advantage of spectrometers with curved VPH dispersers is the very small number of optical elements used (the simplest comprising a grating and a spherical mirror), as well as illumination of mirrors off axis, resulting in greater efficiency and reduction in size. We describe a "Half Offner" spectrometer, an even simpler version of the Offner spectrometer. We present an entirely novel design, the Spherical Transmission Grating Spectrometer (STGS), and discuss exemplary applications, including a design for a double-beam spectrometer without any requirement for a dichroic. This paradigm change in spectrometer design offers an alternative to all-refractive astronomical spectrometer designs, using expensive, fragile lens elements fabricated from CaF2 or even more exotic materials. The unobscured mirror layout avoids a major drawback of the previous generation of catadioptric spectrometer designs. We describe laboratory measurements of the efficiency and image quality of a curved VPH grating in a STGS design, demonstrating, simultaneously, efficiency comparable to planar VPH gratings along with good image quality. The stage is now set for construction of a prototype instrument with impressive performance.

  14. The SPEDE spectrometer

    Science.gov (United States)

    Papadakis, P.; Cox, D. M.; O'Neill, G. G.; Borge, M. J. G.; Butler, P. A.; Gaffney, L. P.; Greenlees, P. T.; Herzberg, R.-D.; Illana, A.; Joss, D. T.; Konki, J.; Kröll, T.; Ojala, J.; Page, R. D.; Rahkila, P.; Ranttila, K.; Thornhill, J.; Tuunanen, J.; Van Duppen, P.; Warr, N.; Pakarinen, J.

    2018-03-01

    The electron spectrometer, SPEDE, has been developed and will be employed in conjunction with the Miniball spectrometer at the HIE-ISOLDE facility, CERN. SPEDE allows for direct measurement of internal conversion electrons emitted in-flight, without employing magnetic fields to transport or momentum filter the electrons. Together with the Miniball spectrometer, it enables simultaneous observation of γ rays and conversion electrons in Coulomb excitation experiments using radioactive ion beams.

  15. The Omicron Spectrometer

    CERN Document Server

    Allardyce, B W

    1976-01-01

    It is intended to build a spectrometer with a large solid angle and a large momentum acceptance at the reconstructed synchrocyclotron at CERN. This spectrometer will have an energy resolution of about 1 MeV for particles with momenta up to about 400 MeV/c.

  16. Migration of iron and manganese into CCA-treated wood in soil contact and the resulting error in leaching results when using energy dispersive x-ray fluorescence spectrometers

    Science.gov (United States)

    Tor P. Schultz; Darrel D. Nicholas; Stan Lebow

    2003-01-01

    In a laboratory leaching study, we found that chromated copper arsenate (CCA) treated wood, which had been exposed to one of five soils examined, unexpectedly appeared to gain significant Cr (47%) when measured with an energy-dispersive x-ray fluorescence instrument (American Wood-Preservers' Association (AWPA) Method A9-01 2001). Analysis of some of the leached...

  17. Moessbauer backscattering spectrometer for mineralogical analysis of the Mars surface

    International Nuclear Information System (INIS)

    Klingelhoefer, G.; Foh, J.; Held, P.; Jaeger, H.; Kankeleit, E.; Teucher, R.

    1992-01-01

    A Moessbauer spectrometer for the mineralogical analysis of the Mars surface is under development. This instrument will be installed on a Mars-Rover, included in the Soviet Union Mars-94/96 Mars mission. Due to power and mass restrictions the electromechanical drive and the electronic components have been extremely miniaturized in comparison to standard systems. Solid state detectors (PIN-diodes) are used for γ- and x-ray detection. The whole spectrometer is controlled by a microprocessor (transputer). An additional application as X-ray fluorescence spectrometer is proposed. (orig.)

  18. Fourier Transform Spectrometer System

    Science.gov (United States)

    Campbell, Joel F. (Inventor)

    2014-01-01

    A Fourier transform spectrometer (FTS) data acquisition system includes an FTS spectrometer that receives a spectral signal and a laser signal. The system further includes a wideband detector, which is in communication with the FTS spectrometer and receives the spectral signal and laser signal from the FTS spectrometer. The wideband detector produces a composite signal comprising the laser signal and the spectral signal. The system further comprises a converter in communication with the wideband detector to receive and digitize the composite signal. The system further includes a signal processing unit that receives the composite signal from the converter. The signal processing unit further filters the laser signal and the spectral signal from the composite signal and demodulates the laser signal, to produce velocity corrected spectral data.

  19. Improved Mass Spectrometer Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The Improved Mass Spectrometer project will develop system requirements and analyze the path to space qualification.   The results of this project...

  20. Micro Plasma Spectrometer

    Data.gov (United States)

    National Aeronautics and Space Administration — The purpose of this IRAD project is to develop a preliminary design elements of miniature electron and ion plasma spectrometers and supporting electronics, focusing...

  1. Digital positron annihilation spectrometer

    International Nuclear Information System (INIS)

    Cheng Bin; Weng Huimin; Han Rongdian; Ye Bangjiao

    2010-01-01

    With the high speed development of digital signal process, the technique of the digitization and processing of signals was applied in the domain of a broad class of nuclear technique. The development of digital positron lifetime spectrometer (DPLS) is more promising than the conventional positron lifetime spectrometer equipped with nuclear instrument modules. And digital lifetime spectrometer has many advantages, such as low noise, long term stability, flexible online or offline digital processing, simple setup, low expense, easy to setting, and more physical information. Digital constant fraction discrimination is for timing. And a new method of optimizing energy windows setting for digital positron lifetime spectrometer is also developed employing the simulated annealing for the convenient use. The time resolution is 220ps and the count rate is 200cps. (authors)

  2. Neutral Kaon Spectrometer 2

    Science.gov (United States)

    Kaneta, M.; Beckford, B.; Fujii, T.; Fujii, Y.; Futatsukawa, K.; Han, Y. C.; Hashimoto, O.; Hirose, K.; Ishikawa, T.; Kanda, H.; Kimura, C.; Maeda, K.; Nakamura, S. N.; Suzuki, K.; Tsukada, K.; Yamamoto, F.; Yamazaki, H.

    2018-04-01

    A large-acceptance spectrometer, Neutral Kaon Spectrometer 2 (NKS2), was newly constructed to explore various photoproduction reactions in the gigaelectronvolt region at the Laboratory of Nuclear Science (LNS, currently ELPH), Tohoku University. The spectrometer consisted of a dipole magnet, drift chambers, and plastic scintillation counters. NKS2 was designed to separate pions and protons in a momentum range of less than 1 GeV/ c, and was placed in a tagged photon beamline. A cryogenic H2/D2 target fitted to the spectrometer were designed. The design and performance of the detectors are described. The results of the NKS2 experiment on analyzing strangeness photoproduction data using a 0.8-1.1 GeV tagged photon beam are also presented.

  3. Chip scale broadly tunable laser for laser spectrometer

    Science.gov (United States)

    Chao, Tien-Hsin; Lu, Thomas; Davis, Scott R.; Anderson, Michael H.

    2016-04-01

    We are developing an innovative Tunable Laser Spectrometer (TLS) that is compact, broad tuning range (> 200 nm) enabled by an innovative chip-scale (a waveguide based architecture), non-mechanical (voltage- controlled tuning), Waveguide External-cavity Semiconductor Laser (WECSL). This WECSL based TLS, with broad tuning range, will enable the simultaneous measurement of multiple gases abundances in Martian and other planetary atmospheres, adsorbed to soil; and bound to rocks. This monolithic, robust, integrated-optic Tunable Laser Absorption Spectrometer (TLS) will operate in the near infrared and infrared spectral bands. The system architecture, principles of operation and applications of the TLS will be reported in this paper.

  4. Development of a Gas Filled Magnet spectrometer coupled with the Lohengrin spectrometer for fission study

    Science.gov (United States)

    Kessedjian, G.; Chebboubi, A.; Faust, H.; Köster, U.; Materna, T.; Sage, C.; Serot, O.

    2013-03-01

    The accurate knowledge of the fission of actinides is necessary for studies of innovative nuclear reactor concepts. The fission yields have a direct influence on the evaluation of the fuel inventory or the reactor residual power after shutdown. A collaboration between the ILL, LPSC and CEA has developed a measurement program on fission fragment distributions at ILL in order to measure the isotopic and isomeric yields. The method is illustrated using the 233U(n,f)98Y reaction. However, the extracted beam from the Lohengrin spectrometer is not isobaric ions which limits the low yield measurements. Presently, the coupling of the Lohengrin spectrometer with a Gas Filled Magnet (GFM) is studied at the ILL in order to define and validate the enhanced purification of the extracted beam. This work will present the results of the spectrometer characterisation, along with a comparison with a dedicated Monte Carlo simulation especially developed for this purpose.

  5. Development of a Gas Filled Magnet spectrometer coupled with the Lohengrin spectrometer for fission study

    Directory of Open Access Journals (Sweden)

    Materna T.

    2013-03-01

    Full Text Available The accurate knowledge of the fission of actinides is necessary for studies of innovative nuclear reactor concepts. The fission yields have a direct influence on the evaluation of the fuel inventory or the reactor residual power after shutdown. A collaboration between the ILL, LPSC and CEA has developed a measurement program on fission fragment distributions at ILL in order to measure the isotopic and isomeric yields. The method is illustrated using the 233U(n,f98Y reaction. However, the extracted beam from the Lohengrin spectrometer is not isobaric ions which limits the low yield measurements. Presently, the coupling of the Lohengrin spectrometer with a Gas Filled Magnet (GFM is studied at the ILL in order to define and validate the enhanced purification of the extracted beam. This work will present the results of the spectrometer characterisation, along with a comparison with a dedicated Monte Carlo simulation especially developed for this purpose.

  6. Compton backscattering axial spectrometer

    International Nuclear Information System (INIS)

    Rad'ko, V.E.; Mokrushin, A.D.; Razumovskaya, I.V.

    1981-01-01

    Compton gamma backscattering axial spectrometer of new design with the 200 time larger aperture as compared with the known spectrometers at the equal angular resolution (at E=159 keV) is described. Collimator unit, radiation source and gamma detector are located in the central part of the spectrometer. The investigated specimen (of cylindrical form) and the so called ''black body'' used for absorption of photons, passed through the specimen are placed in the peripheric part. Both these parts have an imaginary symmetry axis that is why the spectrometer is called axial. 57 Co is used as the gamma source. The 122 keV spectral line which corresponds to the 83 keV backscattered photon serves as working line. Germanium disk detector of 10 mm diameter and 4 mm height has energy resolution not worse than 900 eV. The analysis of results of test measurements of compton water profile and their comparison with data obtained earlier show that only finity of detector resolution can essentially affect the form of Compton profile. It is concluded that the suggested variant of the spectrometer would be useful for determination of Compton profiles of chemical compounds of heavy elements [ru

  7. The dilepton spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Yegneswaran, A.; Claesson, G.; Fulton, R.; Hendrie, D.L.; Krebs, G.F.; Lallier, E.; Letessier-Selvon, A.; Matis, H.S.; Mulera, T.; Naudet, C.; Nesbitt, D.; Roche, G.; Schroeder, L.S.; Seidl, P.A. (Lawrence Berkeley Lab., CA (USA)); Beedoe, S.; Bystricky, J.; Carroll, J.; Gordon, J.; Igo, G.; Oillataguerre, P. (California Univ., Los Angeles (USA)); Christo, S.; Gilot, J.F.; Kirk, P.; Wang, Z.; Xu, I. (Louisiana State Univ., Baton Rouge (USA)); Force, P.; Landaud, G. (Clermont-Ferrand-2 Univ., 63 - Aubiere (France)); Hallman, T.; Madansky, L.; Welsh, R. (Johns Hopkins Univ., Baltimore, MD (USA)); Miller, D. (Northwestern Univ., Evanston, IL (USA))

    1990-05-01

    The dilepton spectrometer (DLS) at Lawrence Berkeley Laboratory's Bevalac has been designed and constructed to investigate the production of electron-positron pairs with low mass and low transverse momentum in proton-nucleus and nucleus-nucleus collisions for incident-beam kinetic energies of 5 A GeV and less. This article briefly recalls the physics objectives of the program, discusses the methodology of the measurement, presents details of the design of the spectrometer and the detector elements, and reports on their performance. Selected experimental results are given to illustrate the capability of the DLS and to demonstrate the level to which it is possible to realize the physics objectives with the spectrometer. (orig.).

  8. The Geostationary Fourier Transform Spectrometer

    Science.gov (United States)

    Key, Richard; Sander, Stanley; Eldering, Annmarie; Blavier, Jean-Francois; Bekker, Dmitriy; Manatt, Ken; Rider, David; Wu, Yen-Hung

    2012-01-01

    The Geostationary Fourier Transform Spectrometer (GeoFTS) is an imaging spectrometer designed for a geostationary orbit (GEO) earth science mission to measure key atmospheric trace gases and process tracers related to climate change and human activity. GEO allows GeoFTS to continuously stare at a region of the earth for frequent sampling to capture the variability of biogenic fluxes and anthropogenic emissions from city to continental spatial scales and temporal scales from diurnal, synoptic, seasonal to interannual. The measurement strategy provides a process based understanding of the carbon cycle from contiguous maps of carbon dioxide (CO2), methane (CH4), carbon monoxide (CO), and chlorophyll fluorescence (CF) collected many times per day at high spatial resolution (2.7kmx2.7km at nadir). The CO2/CH4/CO/CF measurement suite in the near infrared spectral region provides the information needed to disentangle natural and anthropogenic contributions to atmospheric carbon concentrations and to minimize uncertainties in the flow of carbon between the atmosphere and surface. The half meter cube size GeoFTS instrument is based on a Michelson interferometer design that uses all high TRL components in a modular configuration to reduce complexity and cost. It is self-contained and as independent of the spacecraft as possible with simple spacecraft interfaces, making it ideal to be a "hosted" payload on a commercial communications satellite mission. The hosted payload approach for measuring the major carbon-containing gases in the atmosphere from the geostationary vantage point will affordably advance the scientific understating of carbon cycle processes and climate change.

  9. Robotic Variable Interference Filter Imaging Spectrometer (R-VIFIS), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The innovation is a fast, lightweight, and miniaturized Robotic Variable Interference Filter Imaging Spectrometer (R-VIFIS) for a 350-2500nm wavelength range. A pair...

  10. Ultrasensitive Mid-Infrared In Situ Spectrometer for Planetary Atmospheric Analysis, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The Small Business Innovative Research Phase I proposal seeks to develop a compact, robust in situ spectrometer capable of detecting multiple gas-phase species in...

  11. Ultrasensitive Mid-Infrared In Situ Spectrometer for Planetary Atmospheric Analysis Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The Small Business Innovative Research Phase I proposal seeks to develop a compact, robust in situ spectrometer capable of detecting multiple gas-phase species in...

  12. The Omega spectrometer

    CERN Multimedia

    1972-01-01

    The Omega spectrometer which came into action during the year. An array of optical spark chambers can be seen withdrawn from the magnet aperture. In the 'igloo' above the magnet is located the Plumbicon camera system which collects information from the spark chambers.

  13. Speckle-based spectrometer

    DEFF Research Database (Denmark)

    Chakrabarti, Maumita; Jakobsen, Michael Linde; Hanson, Steen Grüner

    2015-01-01

    A novel spectrometer concept is analyzed and experimentally verified. The method relies on probing the speckle displacement due to a change in the incident wavelength. A rough surface is illuminated at an oblique angle, and the peak position of the covariance between the speckle patterns observed...

  14. MIRI spectrometer optical design

    NARCIS (Netherlands)

    Kruizinga, B.; Visser, H.; Pel, J.W.; Moddemeijer, K.; Smorenburg, C.

    2004-01-01

    MIRI (the Mid InfraRed Instrument) is one of the focal plane instruments of the James Webb Space Telescope. The instrument comprises a camera and a spectrometer module. The instrument plays the following key roles in the JWST science program. Discovery of the "first light". Assembly of galaxies:

  15. Magnetic spectrometer Grand Raiden

    International Nuclear Information System (INIS)

    Fujiwara, M.; Akimune, H.; Daito, I.; Fujimura, H.; Fujita, Y.; Hatanaka, K.; Ikegami, H.; Katayama, I.; Nagayama, K.; Matsuoka, N.; Morinobu, S.; Noro, T.; Yoshimura, M.; Sakaguchi, H.; Sakemi, Y.; Tamii, A.; Yosoi, M.

    1999-01-01

    A high-resolution magnetic spectrometer called 'Grand Raiden' is operated at the RCNP ring cyclotron facility in Osaka for nuclear physics studies at intermediate energies. This magnetic spectrometer has excellent ion-optical properties. In the design of the spectrometer, the second-order dispersion matching condition has been taken into account, and almost all the aberration terms such as (x vertical bar θ 3 ), (x vertical bar θφ 2 ), (x vertical bar θ 2 δ) and (x vertical bar θδ 2 ) in a third-order matrix calculation are optimized. A large magnetic rigidity of the spectrometer (K = 1400 MeV) gives a great advantage to measure the charge-exchange ( 3 He, t) reactions at 450 MeV. The ability of the high-resolution measurement has been demonstrated. Various coincidence measurements are performed to study the nuclear structures of highly excited states through decay properties of nuclear levels following nuclear reactions at intermediate energies

  16. Heat of vaporization spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, D. Jr.

    1979-03-01

    Multilayer desorption measurements of various substances adsorbed on a stainless-steel substrate are found to exhibit desorption profiles consistent with a zeroth-order desorption model. The singleness of the desorption transients together with their narrow peak widths makes the technique ideally suited for a heat of vaporization spectrometer for either substance analysis or identification.

  17. Heat of vaporization spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, D. Jr.

    1978-01-01

    Multilayer desorption measurements of various substances adsorbed on a stainless steel substrate are found to exhibit desorption profiles consistent with a zeroth order desorption model. The singleness of the desorption transients together with their narrow peak widths makes the technique ideally suited for a heat of vaporization spectrometer for either substance analysis or identification.

  18. Innovative learning for innovation

    NARCIS (Netherlands)

    Dr.Ir. Hay Geraedts

    2010-01-01

    Introduction Innovation is crucial for companies who have to react to constantly changing markets. Several national and European research institutes stress the importance of developing innovation for small and medium size enterprises (SMEs). This was a trigger to design a minor on strategic

  19. In Situ Mass Spectrometer Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The In Situ Mass Spectrometer projects focuses on a specific subsystem to leverage advanced research for laser-based in situ mass spectrometer development...

  20. Characterization of MEMS FTIR spectrometer

    Science.gov (United States)

    Khalil, Diaa; Sabry, Yasser; Omran, Haitham; Medhat, Mostafa; Hafez, Amr; Saadany, Bassam

    2011-03-01

    In this work we present the full characterization of an optical MEMS Fourier Transform Infra Red FTIR spectrometer fabricated by Deep Reactive Ion Etching DRIE Technology on Silicon substrate. Both electrical and optical properties of the spectrometer are measured. The presented techniques allows to build an engineering model for the spectrometer and to predict its main specifications taking into account the specificity of the MEMS technology used in the spectrometer fabrication.

  1. A novel spectrometer for neutrino experiments

    CERN Document Server

    Pasqualini, Laura

    2015-01-01

    The WA104-NESSiE program developed in the context of the CERN Neutrino Platform, includes an innovative spectrometer to measure the charge and the momentum of muons in 0.5-5 GeV/c range. A tracking apparatus with a spatial resolution of 1 mm was designed, to be placed in a magnetized air volume in order to achieve a charge resolution and mis-identification of better than 1% at 1 GeV/c. Preliminary results obtained by detecting cosmic ray muons are reported.

  2. Fluorescence spectroscopy

    DEFF Research Database (Denmark)

    Bagatolli, Luis

    2016-01-01

    Fluorescence spectroscopy is a powerful experimental tool used by scientists from many disciplines. During the last decades there have been important developments on distinct fluorescence methods, particularly those related to the study of biological phenomena. This chapter discusses the foundati......Fluorescence spectroscopy is a powerful experimental tool used by scientists from many disciplines. During the last decades there have been important developments on distinct fluorescence methods, particularly those related to the study of biological phenomena. This chapter discusses...

  3. Fluorescence Spectra of Highlighter Inks

    Science.gov (United States)

    Birriel, Jennifer J.; King, Damon

    2018-01-01

    Fluorescence spectra excited by laser pointers have been the subject of several papers in TPT. These papers all describe a fluorescence phenomenon in which the reflected laser light undergoes a change in color: this color change results from the combination of some partially reflected laser light and additional colors generated by fluorescent emission. Here we examine the fluorescence spectra of highlighter inks using green and violet laser pointers. We use an RSpec Explorer spectrometer to obtain spectra and compare the emission spectra of blue, green, yellow, orange, pink, and purple highlighters. The website Compound Interest details the chemical composition of highlighter inks; in addition, the site discusses how some base dye colors can be combined to produce the variety commercially available colors. Spectra obtained in this study were qualitatively consistent with the Compound Interest site. We discuss similarities and differences between various highlighter colors and conclude with the relevance of such studies to physics students.

  4. Wide band ENDOR spectrometer

    International Nuclear Information System (INIS)

    Mendonca Filho, C.

    1973-01-01

    The construction of an ENDOR spectrometer operating from 0,5 to 75 MHz within a single band, with ore Klystron and homodine detection, and no fundamental changes on the electron spin resonance spectrometer was described. The ENDOR signal can be detected both by amplitude modulation of the frequency field, or direct detection of the ESR output, which is taken to a signal analyser. The signal-to-noise ratio is raised by averaging rather than filtering avoiding the use of long time constants, providing natural line widths. The experimental apparatus and the spectra obtained are described. A discussion, relating the ENDOR line amplitudes with the experimental conditions is done and ENDOR mechanism, in which there is a relevant presence of cross relaxation is proposed

  5. FAST NEUTRON SPECTROMETER

    Science.gov (United States)

    Davis, F.J.; Hurst, G.S.; Reinhardt, P.W.

    1959-08-18

    An improved proton recoil spectrometer for determining the energy spectrum of a fast neutron beam is described. Instead of discriminating against and thereby"throwing away" the many recoil protons other than those traveling parallel to the neutron beam axis as do conventional spectrometers, this device utilizes protons scattered over a very wide solid angle. An ovoidal gas-filled recoil chamber is coated on the inside with a scintillator. The ovoidal shape of the sensitive portion of the wall defining the chamber conforms to the envelope of the range of the proton recoils from the radiator disposed within the chamber. A photomultiplier monitors the output of the scintillator, and a counter counts the pulses caused by protons of energy just sufficient to reach the scintillator.

  6. Mark III spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Bernstein, D.; Bernstein, J.; Bunnell, K.; Burgueno, G.; Cassell, R.; Collins, B.; Coward, D.; Einsweiler, K.; Eisele, R.; Haber, B.

    1984-10-01

    This paper describes the design, construction and performance of the Mark III, a new general purpose large solid angle spectrometer at SPEAR, the SLAC 2-8 GeV e/sup +/e storage ring. The detector has been designed for the study of exclusive final states in e/sup +/e annihilation, which requires large solid angle coverage combined with charged particle momentum resolution, particle identification, and photon detection efficiency at low energies. (orig.).

  7. Mark III spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Bernstein, D.; Bernstein, J.; Bunnell, K.; Burgueno, G.; Cassell, R.; Collins, B.; Coward, D.; Einsweiler, K.; Eisele, R.; Haber, B. (Stanford Linear Accelerator Center, CA (USA))

    1984-10-01

    This paper describes the design, construction and performance of the Mark III, a new general purpose large solid angle spectrometer at SPEAR, the SLAC 2-8 GeV e/sup +/e/sup -/ storage ring. The detector has been designed for the study of exclusive final states in e/sup +/e/sup -/ annihilation, which requires large solid angle coverage combined with charged particle momentum resolution, particle identification, and photon detection efficiency at low energies.

  8. Magnetic spectrometer control system

    International Nuclear Information System (INIS)

    Lecca, L.A.; Di Paolo, Hugo; Fernandez Niello, Jorge O.; Marti, Guillermo V; Pacheco, Alberto J.; Ramirez, Marcelo

    2003-01-01

    The design and implementation of a new computerized control system for the several devices of the magnetic spectrometer at TANDAR Laboratory is described. This system, as a main difference from the preexisting one, is compatible with almost any operating systems of wide spread use available in PC. This allows on-line measurement and control of all signals from any terminal of a computer network. (author)

  9. ALICE photon spectrometer crystals

    CERN Multimedia

    Maximilien Brice

    2006-01-01

    Members of the mechanical assembly team insert the last few crystals into the first module of ALICE's photon spectrometer. These crystals are made from lead-tungstate, a crystal as clear as glass but with nearly four times the density. When a high-energy particle passes through one of these crystals it will scintillate, emitting a flash of light allowing the energy of photons, electrons and positrons to be measured.

  10. Miniaturized Ion Mobility Spectrometer

    Science.gov (United States)

    Kaye, William J (Inventor); Stimac, Robert M. (Inventor)

    2017-01-01

    By utilizing the combination of a unique electronic ion injection control circuit in conjunction with a particularly designed drift cell construction, the instantly disclosed ion mobility spectrometer (IMS) achieves increased levels of sensitivity, while achieving significant reductions in size and weight. The instant IMS is of a much simpler and easy to manufacture design, rugged and hermetically sealed, capable of operation at high temperatures to at least 250 degrees Centigrade, and is uniquely sensitive, particularly to explosive chemicals.

  11. A spectrometer for the NSF

    International Nuclear Information System (INIS)

    Sanderson, N.E.

    1979-01-01

    It is shown that the capabilities of a magnetic spectrometer are needed to fully exploit the research programme involving charged particle detection to be carried out on the Nuclear Structure Facility (NSF) presently under construction at Daresbury. Performance requirements for such a spectrometer are examined indicating that the QMG/2 spectrometer of the Groningen type is very well suited to the high resolution work which will be possible using beams of light - heavy ions (A < 40). Consequently, and following the recommendations of the Magnetic Spectrometer Working Party, this spectrometer is to be installed at the NSF. (U.K.)

  12. Innovation af innovation

    DEFF Research Database (Denmark)

    Harste, Gorm

    2009-01-01

    , at innovation af innovationen forsøges gennemført på en måde, hvor tiden kræves at forholde sig til sin egen tidslighed i form af fremtid, nutid, fortid og ikke mindst i form af samtidighed. I tiden skal vi iagttage, hvordan vi iagttager tiden. Vi dobbelt-koder tiden på samme måde, som forskning forsker i...... organisationssystemerne. De to typer systemer kan noget helt bestemt med fænomenet tid. De kan synkronisere. Analyseres organisationssystemer ser vi, imidlertid at innovation kræver ro. Stærkt innovative systemer er militærsystemet og kunstsystemet, der også inddrages, og hvor vi ser paradokset mellem innovation og...... involution. Tid er med et medium og ikke et lufttomt rum. Tid er end ikke en gasart, men udgør et solidt fluidum, som samfundet bader i og flyder i, konstant i bevægelse. Reformer forudsætter former, og innovation forudsætter involution. Kun sådan muliggøres evolution....

  13. Orchestrating innovation

    NARCIS (Netherlands)

    Berkers, F.T.H.M.; Klein Woolthuis, R.J.A.; Boer, J. de

    2015-01-01

    Orchestrating Innovation increases the probability of success, minimizing the probability of failure of technological innovations by creating sustained societal and economic value. Orchestrating innovation propagates to take into account and actively involve all relevant stakeholders of the (future)

  14. Fluorescent standards for photodynamic therapy

    Science.gov (United States)

    Belko, N.; Kavalenka, S.; Samtsov, M.

    2016-08-01

    Photodynamic therapy is an evolving technique for treatment of various oncological diseases. This method employs photosensitizers - species that lead to death of tumor cells after the photoactivation. For further development and novel applications of photodynamic therapy new photosensitizers are required. After synthesis of a new photosensitizer it is important to know its concentration in different biological tissues after its administration and distribution. The concentration is frequently measured by the extraction method, which has some disadvantages, e.g. it requires many biological test subjects that are euthanized during the measurement. We propose to measure the photosensitizer concentration in tissue by its fluorescence. For this purpose fluorescent standards were developed. The standards are robust and simple to produce; their fluorescence signal does not change with time. The fluorescence intensity of fluorescent standards seems to depend linearly on the dye concentration. A set of standards thus allow the calibration of a spectrometer. Finally, the photosensitizer concentration can be determined by the fluorescence intensity after comparing the corresponding spectrum with spectra of the set of fluorescent standards. A biological test subject is not euthanized during this kind of experiment. We hope this more humane technique can be used in future instead of the extraction method.

  15. MASS SPECTROMETER LEAK

    Science.gov (United States)

    Shields, W.R.

    1960-10-18

    An improved valve is described for precisely regulating the flow of a sample fluid to be analyzed, such as in a mass spectrometer, where a gas sample is allowed to "leak" into an evacuated region at a very low, controlled rate. The flow regulating valve controls minute flow of gases by allowing the gas to diffuse between two mating surfaces. The structure of the valve is such as to prevent the corrosive feed gas from contacting the bellows which is employed in the operation of the valve, thus preventing deterioration of the bellows.

  16. Open Innovation

    OpenAIRE

    Gassmann, Oliver; Enkel, Ellen

    2006-01-01

    In the past 10 years, numerous interesting articles, book chapters, and books have been written on open innovation strategies in mainly large companies. While closed innovation models have resulted in important breakthrough innovations, many large companies have abandoned vertical integration strategies in recent years and have moved toward a combination of both closed and open innovation models that are used for reaching different sets of innovative goals. The definition of open innovation a...

  17. The SPEDE electron spectrometer

    CERN Document Server

    O'Neill, George

    This thesis presents SPEDE (SPectrometer for Electron DEtection) and documents its construction, testing and performance during commissioning at Jyvaskyla, Finland, before deployment at the HIE-ISOLDE facility at CERN coupled with the MINIBALL array to perform in-beam electron-gamma spectroscopy using post-accelerated radioactive ion beams. Commissioning experiments took place in two two-day stints during spring 2015, coupled with several JUROGAMII gamma-detectors. This spectrometer will help aid in fully understanding exotic regions of the nuclear chart such as regions with a high degree of octupole deformation, and in those nuclei exhibiting shape coexistence. For the rst time, electron spectroscopy has been performed at the target position from states populated in accelerated nuclei via Coulomb excitation. The FWHM of SPEDE is approximately 7 keV at 320 keV, and Doppler correction was possible to improve Doppler broadened peaks. The results are intended to give the reader a full understanding of the dete...

  18. Prototype Neutron Energy Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Stephen Mitchell, Sanjoy Mukhopadhyay, Richard Maurer, Ronald Wolff

    2010-06-16

    The project goals are: (1) Use three to five pressurized helium tubes with varying polyethylene moderators to build a neutron energy spectrometer that is most sensitive to the incident neutron energy of interest. Neutron energies that are of particular interest are those from the fission neutrons (typically around 1-2 MeV); (2) Neutron Source Identification - Use the neutron energy 'selectivity' property as a tool to discriminate against other competing processes by which neutrons are generated (viz. Cosmic ray induced neutron production [ship effect], [a, n] reactions); (3) Determine the efficiency as a function of neutron energy (response function) of each of the detectors, and thereby obtain the composite neutron energy spectrum from the detector count rates; and (4) Far-field data characterization and effectively discerning shielded fission source. Summary of the presentation is: (1) A light weight simple form factor compact neutron energy spectrometer ready to be used in maritime missions has been built; (2) Under laboratory conditions, individual Single Neutron Source Identification is possible within 30 minutes. (3) Sources belonging to the same type of origin viz., (a, n), fission, cosmic cluster in the same place in the 2-D plot shown; and (4) Isotopes belonging to the same source origin like Cm-Be, Am-Be (a, n) or Pu-239, U-235 (fission) do have some overlap in the 2-D plot.

  19. Detection of Counterfeit Tequila by Fluorescence Spectroscopy

    Directory of Open Access Journals (Sweden)

    José Manuel de la Rosa Vázquez

    2015-01-01

    Full Text Available An ultraviolet (UV light induced fluorescence study to discriminate fake tequila from genuine ones is presented. A portable homemade system based on four light emitting diodes (LEDs from 255 to 405 nm and a miniature spectrometer was used. It has been shown that unlike fake and silver tequila, which produce weak fluorescence signal, genuine mixed, rested, and aged tequilas show high fluorescence emission in the range from 400 to 750 nm. The fluorescence intensity grows with aging in 100% agave tequila. Such fluorescence differences can even be observed with naked eyes. The presented results demonstrate that the fluorescence measurement could be a good method to detect counterfeit tequila.

  20. LADEE Neutral Mass Spectrometer Data

    Data.gov (United States)

    National Aeronautics and Space Administration — This bundle contains the data collected by the Neutral Mass Spectrometer (NMS) instrument aboard the Lunar Atmosphere and Dust Environment Explorer (LADEE)...

  1. Applications in oil industry of a wavelength dispersive X-ray fluorescence spectrometer (WDXRF); Applications en petrochimie, d'un spectrometre de fluorescence de rayons X d'entree de gamme, dispersif en longueur d'onde (WDXRF)

    Energy Technology Data Exchange (ETDEWEB)

    Lienemann, C.P.; Roche, E. [Institut Francais du Petrole (IFP Lyon), Dir. Physique et Analyse, Lab. de Fluorescence-X, Absorption et Emission Atomique, 69 - Vernaison (France); Yellepeddi, R.; Bonvin, D. [Thermo Electron SA, Ecublens (Switzerland); Matula, G. [Thermo Electron, 91 - Courtaboeuf (France)

    2004-11-01

    X-ray fluorescence spectrometry (WDXRF) is a broadly used technique in oil chemistry. It can be used to detect Si, S, Pb, Ni, V, Cl, Br....Now WDXRF equipment is composed of low power X-ray tubes that makes unnecessary a cooling system for the detector. This paper assesses the use of WDXRF (with a 50 W tube) for the quantitative analysis of S in various samples of oil products. The advantages of this method are the rapidity of the analysis, the continuous availability of the equipment and its easy handling that implies that this equipment could be used in a self-service way. This test has allowed us to define the specificities of the technique: -) a 2 ml sample is sufficient, -) a quantification limit of 2 ppm has been obtained for an analysis time of 2 mn, and -) sulfur concentrations ranging from 2 ppm to 3%. (A.C.)

  2. Orchestrating innovation

    OpenAIRE

    Berkers, F.T.H.M.; Klein Woolthuis, R.J.A.; Boer, J. de

    2015-01-01

    Orchestrating Innovation increases the probability of success, minimizing the probability of failure of technological innovations by creating sustained societal and economic value. Orchestrating innovation propagates to take into account and actively involve all relevant stakeholders of the (future) ecosystem in which the innovation will, can or has to be adopted.

  3. Innovative didaktik

    DEFF Research Database (Denmark)

    Lund, Birthe

    Innovative didaktik. This deals with innovative didaktik from at methodological point of view in three ways - how to define the concept, how to develop it and how analyse it. Issues analysed: How to create innovative students? How to create innovative learning envoriments? These are core questions...

  4. Mindful innovation

    DEFF Research Database (Denmark)

    Olsen, Poul Bitsch

    2008-01-01

    Mindful innovation is an approach to innovation that pays attention to people's experience in an organization rather than to formal organization or social role.......Mindful innovation is an approach to innovation that pays attention to people's experience in an organization rather than to formal organization or social role....

  5. The nanopore mass spectrometer

    Science.gov (United States)

    Bush, Joseph; Maulbetsch, William; Lepoitevin, Mathilde; Wiener, Benjamin; Mihovilovic Skanata, Mirna; Moon, Wooyoung; Pruitt, Cole; Stein, Derek

    2017-11-01

    We report the design of a mass spectrometer featuring an ion source that delivers ions directly into high vacuum from liquid inside a capillary with a sub-micrometer-diameter tip. The surface tension of water and formamide is sufficient to maintain a stable interface with high vacuum at the tip, and the gas load from the interface is negligible, even during electrospray. These conditions lifted the usual requirement of a differentially pumped system. The absence of a background gas also opened up the possibility of designing ion optics to collect and focus ions in order to achieve high overall transmission and detection efficiencies. We describe the operation and performance of the instrument and present mass spectra from solutions of salt ions and DNA bases in formamide and salt ions in water. The spectra show singly charged solute ions clustered with a small number of solvent molecules.

  6. BNL multiparticle spectrometer software

    International Nuclear Information System (INIS)

    Saulys, A.C.

    1984-01-01

    This paper discusses some solutions to problems common to the design, management and maintenance of a large high energy physics spectrometer software system. The experience of dealing with a large, complex program and the necessity of having the program controlled by various people at different levels of computer experience has led us to design a program control structure of mnemonic and self-explanatory nature. The use of this control language in both on-line and off-line operation of the program will be discussed. The solution of structuring a large program for modularity so that substantial changes to the program can be made easily for a wide variety of high energy physics experiments is discussed. Specialized tools for this type of large program management are also discussed

  7. A Moessbauer effect spectrometer

    International Nuclear Information System (INIS)

    Fayek, M.K.; Abbas, Y.M.; Bahgat, A.A.

    1983-01-01

    A Moessbauer effect spectrometer of Harwell type is installed and put in operation. The driving system is of a constant acceleration mode with a velocity range 40mm/sec. and associated to a 1024 multichannel analyser working in a multiscalar time mode. The gamma ray sources are 50 mCi Co 57 in Pd and 20 mCi Snsup(119m) in Ba Sn(O) 3 . Measurements are taken with the source kept at room temperature, while the absorber can be maintained at various temperatures. Gamma ray resonance spectra of different standard samples are obtained. Zero velocity and magnetic field calibration curves are deduced. Examples of some Moessbauer spectra for running investigated materials with a comprehensive general description are also given

  8. Photo ion spectrometer

    Science.gov (United States)

    Gruen, Dieter M.; Young, Charles E.; Pellin, Michael J.

    1989-01-01

    A charged particle spectrometer for performing ultrasensitive quantitative analysis of selected atomic components removed from a sample. Significant improvements in performing energy and angular refocusing spectroscopy are accomplished by means of a two dimensional structure for generating predetermined electromagnetic field boundary conditions. Both resonance and non-resonance ionization of selected neutral atomic components allow accumulation of increased chemical information. A multiplexed operation between a SIMS mode and a neutral atomic component ionization mode with EARTOF analysis enables comparison of chemical information from secondary ions and neutral atomic components removed from the sample. An electronic system is described for switching high level signals, such as SIMS signals, directly to a transient recorder and through a charge amplifier to the transient recorder for a low level signal pulse counting mode, such as for a neutral atomic component ionization mode.

  9. The Philippine spectrometer

    International Nuclear Information System (INIS)

    Juliano, J.O.

    1965-01-01

    A notable project for international collaboration, in which participants from Indonesia, Korea, Thailand, China and the Philippines are working together, has been launched in the Philippines with Indian assistance under the aegis of the Agency. This is a regional training and research programme using a neutron crystal spectrometer, which has been established since January 1965 at the Philippine Atomic Research Centre in Diliman, Quezon City, Philippines. It is called the IPA Project after the signatories to a five year trilateral agreement, namely, the Government of India,the Republic of the Philippines, and the International Atomic Energy Agency. The programme is administered by a Joint Committee composed of one representative each of the Philippines, India and the Agency. The objective of this cooperative venture is to establish a research centre on neutron diffraction in which scientists and technicians from any Member State of IAEA in South Asia, South-East Asia and Pacific, or Far East regions could come to participate in research and training. Studies in solid state physics, such a s the structure determination of alloys and organic crystals, studies on the orientation of magnetic moments in the lattice of magnetic substances, and other problems based on elastic and inelastic scattering of neutrons are undertaken. There are a number of research reactors in this region where neutron spectrometers can be utilized and the recent establishment of this cooperative international research and training programme has been a timely one for this area of the world. Indeed, a number of other countries have shown a strong growing interest in the development of the project

  10. Magnetic quadrupole and solenoidal spectrometers

    International Nuclear Information System (INIS)

    Laurent, H.; Schapira, J.P.

    1979-01-01

    General optical properties of magnetic quadrupole spectrometers are reviewed, together with experimental purposes for nuclear physics: background reduction, magnetic rigidity filtering for extreme forward angles measurements, light charged particle discrimination, ionic charge state separation, time of flight mass spectrometry and fast collection of radioactive nuclear reaction products. Possibility of alternative devices such as superconducting quadrupoles or solenoid spectrometers are discussed. (Auth.)

  11. The ALICE forward muon spectrometer

    Indian Academy of Sciences (India)

    ICE detector will allow to identify the quarkonium states through both the dielectron and the dimuon channels. For this purpose the apparatus is equipped with a transition radiation detector in its central part and with a forward muon spectrometer at small angles. After a brief description of the forward muon spectrometer, ...

  12. ATF beamline 1 analysis spectrometer

    International Nuclear Information System (INIS)

    Fernow, R.C.; Kirk, H.G.; Ulc, S.

    1993-01-01

    We describe the design parameters and expected performance of the analysis spectrometer for beamline 1 at the BNL Accelerator Test Facility. The spectrometer should be well suited for measuring the change in energy caused by the first generation laser acceleration experiments

  13. Motor Oil Classification Based on Time-Resolved Fluorescence

    OpenAIRE

    Mu, Taotao; Chen, Siying; Zhang, Yinchao; Guo, Pan; Chen, He; Meng, Fandong

    2014-01-01

    A time-resolved fluorescence (TRF) technique is presented for classifying motor oils. The system is constructed with a third harmonic Nd:YAG laser, a spectrometer, and an intensified charge coupled device (ICCD) camera. Steady-state and time-resolved fluorescence (TRF) measurements are reported for several motor oils. It is found that steady-state fluorescence is insufficient to distinguish the motor oil samples. Then contour diagrams of TRF intensities (CDTRFIs) are acquired to serve as uniq...

  14. Collaborative innovation

    DEFF Research Database (Denmark)

    Torfing, Jacob; Sørensen, Eva; Hartley, Jean

    2013-01-01

    There are growing pressures for the public sector to be more innovative but considerable disagreement about how to achieve it. This article uses institutional and organizational analysis to compare three major public innovation strategies. The article confronts the myth that the market......-driven private sector is more innovative than the public sector by showing that both sectors have a number of drivers of as well as barriers to innovation, some of which are similar, while others are sector specific. The article then systematically analyzes three strategies for innovation: New Public Management...... for enhancing public innovation is contingent rather than absolute. Some contingencies for each strategy are outlined....

  15. Neutron range spectrometer

    Science.gov (United States)

    Manglos, Stephen H.

    1989-06-06

    A neutron range spectrometer and method for determining the neutron energy spectrum of a neutron emitting source are disclosed. Neutrons from the source are collimnated along a collimation axis and a position sensitive neutron counter is disposed in the path of the collimated neutron beam. The counter determines positions along the collimation axis of interactions between the neutrons in the neutron beam and a neutron-absorbing material in the counter. From the interaction positions, a computer analyzes the data and determines the neutron energy spectrum of the neutron beam. The counter is preferably shielded and a suitable neutron-absorbing material is He-3. The computer solves the following equation in the analysis: ##EQU1## where: N(x).DELTA.x=the number of neutron interactions measured between a position x and x+.DELTA.x, A.sub.i (E.sub.i).DELTA.E.sub.i =the number of incident neutrons with energy between E.sub.i and E.sub.i +.DELTA.E.sub.i, and C=C(E.sub.i)=N .sigma.(E.sub.i) where N=the number density of absorbing atoms in the position sensitive counter means and .sigma. (E.sub.i)=the average cross section of the absorbing interaction between E.sub.i and E.sub.i +.DELTA.E.sub.i.

  16. UCN gravitational spectrometer

    International Nuclear Information System (INIS)

    Kawabata, Yuji

    1988-01-01

    Concept design is carried out of two types of ultra cold neutron scallering equipment using the fall-focusing principle. One of the systems comprises a vertical gravitational spectrometer and the other includes a horizontal gravitation analyzer. A study is made of their performance and the following results are obtained. Fall-focusing type ultra cold neutron scattering equipment can achieve a high accuracy for measurement of energy and momentum. Compared with conventional neutron scattering systems, this type of equipment can use neutron very efficiently because scattered neutrons within a larger solid angle can be used. The maximum solid angle is nearly 4π and 2π for the vertical and horizontal type, respectively. Another feature is that the size of equipment can be reduced. In the present concept design, the equipment is spherical with a diameter of about 1 m, as compared with NESSIE which is 6.7 m in length and 4.85 m in height with about the same accuracy. Two horizontal analyzers and a vertical spectroscope are proposed. They are suitable for angle-dependent non-elastic scattering in the neutron velocity range of 6∼15 m/s, pure elastic scattering in the range of 4∼7 m/s, or angle-integration non-elastic scattering in the range of 4∼15 m/s. (N.K.)

  17. Respiratory mass spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Mostert, J.W. (Pretoria Univ. (South Africa). Dept. of Anesthesiology)

    1983-06-01

    The high degree of technical perfection of the respiratory mass spectrometer has rendered the instrument feasible for routine monitoring of anesthetized patients. It is proposed that the difference between inspired and expired oxygen tension in mm Hg be equated with whole body oxygen consumption in ml/min/M/sup 2/ body-surface area at STPD, by the expedient of multiplying tension-differences by a factor of 2. Years of experience have confirmed the value of promptly recognizing sudden drops in this l/E tension difference below 50 mm Hg indicative of metabolic injury from hypovolemia or respiratory depression. Rises in l/E tension-differences were associated with shivering as well as voluntary muscle activity. Tension differences of less than 25 mm Hg (equated with a whole-body O/sub 2/ consumption of less than 50 ml O/sub 2//min/M/sup 2/) occurred in a patient in the sitting position for posterior fossa exploration without acidosis, hypoxia or hypotension for several hours prior to irreversible cardiac arrest. The value of clinical monitoring by mass spectrometry is especially impressive in open-heart surgery.

  18. CHIRON – A new high resolution spectrometer for CTIO

    Directory of Open Access Journals (Sweden)

    Marcy G.W.

    2011-07-01

    Full Text Available Small telescopes can play an important role in the search for exoplanets because they offer an opportunity for high cadence observations that are not possible with large aperture telescopes. However, there is a shortage of high resolution spectrometers for precision Doppler planet searches. We report on an innovative design for CHIRON, an inexpensive spectrometer that we are building for the 1.5-m telescope at CTIO in Chile. The resolution will be R >80.000, the spectral format spanning 410 to 880 nm. The total throughput of the telescope and spectrometer will be better than 12%, comparable with the efficiency of state-of-the-art spectrometers. The design is driven by the requirements for precision Doppler searches for exoplanets using an iodine cell. The optical layout is a classical echelle with 140 mm beam size. The bench-mounted spectrometer will be fibre-fed followed by an image slicer. An apochromatic refractor is used as the camera. Image quality and throughput of the design are excellent over the full spectral range. Extensive use of commercially available components and avoidance of complicated custom optics are key for quick and resource-efficient implementation.

  19. Adaptive Computed Tomography Imaging Spectrometer Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The present proposal describes the development of an adaptive Computed Tomography Imaging Spectrometer (CTIS), or "Snapshot" spectrometer which can "instantaneously"...

  20. Technology Innovation

    Science.gov (United States)

    EPA produces innovative technologies and facilitates their creation in line with the Agency mission to create products such as the stormwater calculator, remote sensing, innovation clusters, and low-cost air sensors.

  1. Science Innovation

    Science.gov (United States)

    EPA provides innovative research activities that help transform the protection of human health and the environment with high-risk, high-reward Pathfinder Innovation Projects, the P3 student competition, and low-cost air monitoring.

  2. Innovation hubs

    DEFF Research Database (Denmark)

    O´Hara, J.; Hansen, Poul H. Kyvsgård; Turner, N.

    2008-01-01

    hubs that attempts to discover the causes of failure of innovation hubs through the comparison of successful and failed hubs. Success factors for innovation hubs are also discussed and suggestions are made as to lessons that can be learned from the experiences of innovation hubs."......"Whilst ‘incremental innovation' is an imperative for the short-to-medium term success of a company, there is also a need for companies to engage in innovation activity that goes beyond the incremental in order to guarantee long-term success. However, such ‘radical innovation' (RI) poses new...... of separation from the culture and routines of the mainstream organisation. Unfortunately, it would appear that many attempts to set-up innovation hubs have ended in failure within a few years; not before considerable time, effort and resource has been expended. This paper reports on a study of six innovation...

  3. Responsive Innovation

    DEFF Research Database (Denmark)

    Pedersen, Carsten

    Although the importance of stakeholder networks has been recognized in recent years, a non-teleological model that incorporates their collective sensing into innovation processes has so far not been developed. Hence, this paper argues that traditional linear and sequential innovation models...... are insufficient in hypercompetitive environments. Instead, it is proposed that companies should ground their innovation processes in the collective sensing of frontline-employees and customers that operate around the organizational periphery. This frames the concept of responsive innovation, where key...

  4. Political innovations

    DEFF Research Database (Denmark)

    Sørensen, Eva

    2017-01-01

    are mainly interested in assessing and promoting innovations in public service delivery, but have paid little or no attention to the need for innovations in polity, politics and policy. This article develops a research agenda for studying innovations in political institutions, in the political process...... and in policy outputs. It proposes a number of research themes related to political innovations that call for scholarly attention, and identifies push and pull factors influencing the likelihood that these themes will be addressed in future research....

  5. Brugerdreven innovation

    DEFF Research Database (Denmark)

    Helms, Niels Henrik; Larsen, Lasse Juel

    2007-01-01

    På et generelt plan er vores afsæt et opgør med traditionelle modeller for kreativitet og innovation. Artiklen mener, at brugerdreven innovation ikke bare en god idé, men en beskrivelse af, hvordan innovation finder sted. Vores afsæt er interaktionsdesign, hvor vi bygger på den antagelse...

  6. Facilitating innovations

    NARCIS (Netherlands)

    Buurma, J.S.; Visser, A.J.; Migchels, G.

    2011-01-01

    Many innovations involve changes which transcend the individual business or are only achievable when various businesses and/or interested parties take up the challenge together. In System Innovation Programmes, the necessary innovations are facilitated by means of workshops related to specific areas

  7. Multi-way based calibration transfer between two Raman spectrometers.

    Science.gov (United States)

    Kompany-Zareh, Mohsen; van den Berg, Frans

    2010-06-01

    A standardization algorithm based on the application of Tucker3 models on the tensorized measurement signals is proposed to transfer calibration information between two Raman spectrometers. The secondary instrument in this study is a low cost and portable CCD based unit employing an efficient 532 nm green laser. The primary instrument is a high performance Fourier-transform based laboratory instrument using a low efficiency NIR laser at 1064 nm, albeit with very limited sample fluorescence interference. This work is a first investigation of calibration transfer on Raman spectral data which include different values of fluorescent background from one instrument to the other. The spectra of a small set of calibration samples are measured on both spectrometers. Using the ability of Tucker3 to estimate missing values in tensorized data, we reconstruct the spectrum of a new sample on the primary instrument based on its measured response of the secondary instrument without the need for constructing an explicit transfer model. This way spectra of a prediction sample measured on one spectrometer can be successfully transferred to another spectrometer as if it has been measured directly on the latter. Hence, the task of calibration transfer among instruments is posed as a missing data problem. A discrete wavelet transform is performed to improve the predictive ability. Performance criteria for judging the success of the calibration transfer are reported as the standard error of prediction for estimation of samples in a prediction set. By comparison, the proposed Tucker3 based standardization method shows a better performance as compared to piecewise direct standardization. The method is expected to be applicable for performing calibration transfer using data from instruments other than Raman spectrometers.

  8. Elements of Tiny Plasma Spectrometers

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to advance major elements of a miniaturized plasma spectrometer for flight on future missions. This type of instrument has been developed and successfully...

  9. Moessbauer spectrometer on integrated circuits

    International Nuclear Information System (INIS)

    Tomov, T.; Spasov, A.; Kunov, B.

    1978-01-01

    Two versions of the small-size high-quality Moessbauer spectrometer for 57 Fe spectroscopy are developed. The first version includes a proportion counter, a preamplifier, a one-chennel analyzer, a timer, and a scaler. The spectrometer is intended for measuring characteristic points of the Moessbauer-spectra and operates at constant velocities. The spectrometer parameters are as follows: integral non-linearity of the entire channel about 1%, maximum load for 14 keV line 8x10 4 pulse/s. The second version uses a multichannel time analyzer as a recording device. The spectrometer operates in the saw-toothed velocity modulation, the integral nonlinearity of the modulation being at least 0.1%

  10. Miniaturized Waveguide Fourier Transform Spectrometer

    Data.gov (United States)

    National Aeronautics and Space Administration — To demonstrate the efficacy of a spectrometer-on-chip system for in-situ and remote monitoring of planetary atmospheric and surface chemistry, physics, and surface...

  11. Versatile central spectrometer for ISABELLE

    International Nuclear Information System (INIS)

    Cheng, D.; Goulianso, K.; Knapp, B.; Rosen, J.; Schlein, P.

    1975-01-01

    A large aperture magnetic spectrometer is proposed to study hadrons and leptons produced in the central region at Isabelle. The essential element of the spectrometer is a large double-dipole magnet system with common flux return straddling the intersection region. The air gaps provide magnetic analysis of charged particle for up to 50 percent of the azimuthal angular range. Drift chambers, Cherenkov counters and shower detectors positioned on both sides of the beam lines comprise two spectrometers for analysis of hadrons and electrons. Muons can be momentum analyzed over a large fraction at the azimuthal angle by utilizing the upper and lower sections on the magnet yoke to provide hadron filtering and magnetic deflection. Cylindrical chambers around the vacuum pipe provide multiplicity information for events of interest. The proposed magnet configuration allows unobscured coverage of smaller angle particles with the addition of septum magnet spectrometers downstream of the central magnet in both arms.

  12. Portable Remote Imaging Spectrometer (PRISM)

    Data.gov (United States)

    National Aeronautics and Space Administration — Develop an UV-NIR (350nm to 1050 nm) portable remote imaging spectrometer (PRISM) for flight on a variety of airborne platforms with high SNR and response uniformity...

  13. Electron spectrometers with internal conversion

    International Nuclear Information System (INIS)

    Suita, J.C.; Lemos Junior, O.F.; Auler, L.T.; Silva, A.G. da

    1981-01-01

    The efforts that the Department of Physics (DEFI) of Institute of Nuclear Engineering (IEN) are being made aiming at adjusting the electron spectrometers with internal conversion to its necessity, are shown. (E.G.) [pt

  14. Open innovation

    DEFF Research Database (Denmark)

    Bogers, Marcel; Chesbrough, Henry; Moedas, Carlos

    2018-01-01

    Open innovation is now a widely used concept in academia, business, and policy making. This article describes the state of open innovation at the intersection of research, practice, and policy. It discusses some key trends (e.g., digital transformation), challenges (e.g., uncertainty......), and potential solutions (e.g., EU funding programs) in the context of open innovation and innovation policy. With this background, the authors introduce select papers published in this Special Section of California Management Review that were originally presented at the second annual World Open Innovation...

  15. Coastal Research Imaging Spectrometer

    Science.gov (United States)

    Lucey, Paul G.; Williams, Timothy; Horton, Keith A.

    2004-01-01

    The Coastal Research Imaging Spectrometer (CRIS) is an airborne remote sensing system designed specifically for research on the physical, chemical, and biological characteristics of coastal waters. The CRIS includes a visible-light hyperspectral imaging subsystem for measuring the color of water, which contains information on the biota, sediment, and nutrient contents of the water. The CRIS also includes an infrared imaging subsystem, which provides information on the temperature of the water. The combination of measurements enables investigation of biological effects of both natural and artificial flows of water from land into the ocean, including diffuse and point-source flows that may contain biological and/or chemical pollutants. Temperature is an important element of such measurements because temperature contrasts can often be used to distinguish among flows from different sources: for example, a sewage outflow could manifest itself in spectral images as a local high-temperature anomaly. Both the visible and infrared subsystems scan in pushbroom mode: that is, an aircraft carrying the system moves along a ground track, the system is aimed downward, and image data are acquired in across-track linear arrays of pixels. Both subsystems operate at a frame rate of 30 Hz. The infrared and visible-light optics are adjusted so that both subsystems are aimed at the same moving swath, which has across-track angular width of 15 . Data from the infrared and visible imaging subsystems are stored in the same file along with aircraft- position data acquired by a Global Positioning System receiver. The combination of the three sets of data is used to construct infrared and hyperspectral maps of scanned areas (see figure). The visible subsystem is based on a grating spectrograph and a rapid-readout charge-coupled-device camera. Images of the swatch are acquired in 256 spectral bands at wavelengths from 400 to 800 nm. The infrared subsystem, which is sensitive in a single

  16. Fluorescence detection of dental calculus

    International Nuclear Information System (INIS)

    Gonchukov, S; Sukhinina, A; Vdovin, Yu; Biryukova, T

    2010-01-01

    This work is devoted to the optimization of fluorescence dental calculus diagnostics in optical spectrum. The optimal wavelengths for fluorescence excitation and registration are determined. Two spectral ranges 620 – 645 nm and 340 – 370 nm are the most convenient for supra- and subgingival calculus determination. The simple implementation of differential method free from the necessity of spectrometer using was investigated. Calculus detection reliability in the case of simple implementation is higher than in the case of spectra analysis at optimal wavelengths. The use of modulated excitation light and narrowband detection of informative signal allows us to decrease essentially its diagnostic intensity even in comparison with intensity of the low level laser dental therapy

  17. X-ray spectrometer with a low-cost SiC photodiode

    Science.gov (United States)

    Zhao, S.; Lioliou, G.; Barnett, A. M.

    2018-04-01

    A low-cost Commercial-Off-The-Shelf (COTS) 4H-SiC 0.06 mm2 UV p-n photodiode was coupled to a low-noise charge-sensitive preamplifier and used as photon counting X-ray spectrometer. The photodiode/spectrometer was investigated at X-ray energies from 4.95 keV to 21.17 keV: a Mo cathode X-ray tube was used to fluoresce eight high-purity metal foils to produce characteristic X-ray emission lines which were used to characterise the instrument. The energy resolution (full width at half maximum, FWHM) of the spectrometer was found to be 1.6 keV to 1.8 keV, across the energy range. The energy linearity of the detector/spectrometer (i.e. the detector's charge output per photon as a function of incident photon energy across the 4.95 keV to 21.17 keV energy range), as well as the count rate linearity of the detector/spectrometer (i.e. number of detected photons as a function of photon fluence at a specific energy) were investigated. The energy linearity of the detector/spectrometer was linear with an error spectrometer was linear with an error spectrometers is attractive for nanosatellite/CubeSat applications (including solar flare monitoring), and for cost sensitive industrial uses.

  18. Informal Innovation

    DEFF Research Database (Denmark)

    Hartmann, Mia Rosa Koss; Hartmann, Rasmus Koss

    Informal innovation, defined as the development and putting-into-use of novel solutions by non-R&D employees without prior formal approval from or subsequent revealing to superiors, has been recurrently observed in organizational research. But even as it is increasingly recognized that R......, creating a need for further informal innovation. We discuss the generalizability of these findings and implications for research and managerial practice.......&D is not the only plausible source of innovation inside organizations, informal innovation has yet to be systematically explored or theorized. We propose a theory of informal innovation based on analyses of prior literature and mixed-method, multi-site studies of innovation at the working level of two extreme...

  19. Spectrometers for compact neutron sources

    Science.gov (United States)

    Voigt, J.; Böhm, S.; Dabruck, J. P.; Rücker, U.; Gutberlet, T.; Brückel, T.

    2018-03-01

    We discuss the potential for neutron spectrometers at novel accelerator driven compact neutron sources. Such a High Brilliance Source (HBS) relies on low energy nuclear reactions, which enable cryogenic moderators in very close proximity to the target and neutron optics at comparably short distances from the moderator compared to existing sources. While the first effect aims at increasing the phase space density of a moderator, the second allows the extraction of a large phase space volume, which is typically requested for spectrometer applications. We find that competitive spectrometers can be realized if (a) the neutron production rate can be synchronized with the experiment repetition rate and (b) the emission characteristics of the moderator can be matched to the phase space requirements of the experiment. MCNP simulations for protons or deuterons on a Beryllium target with a suitable target/moderator design yield a source brightness, from which we calculate the sample fluxes by phase space considerations for different types of spectrometers. These match closely the figures of todays spectrometers at medium flux sources. Hence we conclude that compact neutron sources might be a viable option for next generation neutron sources.

  20. Inverse-magnetron mass spectrometer

    International Nuclear Information System (INIS)

    Pakulin, V.N.

    1979-01-01

    Considered is the operation of a typical magnetron mass spectrometer with an internal ion source and that of an inverse magnetron mass spectrometer with an external ion source. It is found that for discrimination of the same mass using the inverse design of mass spectrometers it is possible to employ either r 2 /r 1 times lesser magnetic fields at equal accelerating source-collector voltages, or r 2 /r 1 higher accelerating voltages at equal magnetic fields, as compared to the typical design (r 1 and r 2 being radii of the internal and external electrodes of the analyser, respectively). The design of an inverse-magnetron mass spectrometer is described. The mass analyzer is formed by a cylindrical electrode of 3 mm diameter and a coaxial tubular cylinder of 55 mm diameter. External to the analyzer is an ionizing chamber at the pressure of up to 5x10 -6 torr. The magnetic field along the chamber axis produced by a solenoid was 300 Oe. At the accelerating voltage of 100 V and mass 28, the spectrometer has a resolution of 30 at a half-peak height

  1. Innovation @ NASA

    Science.gov (United States)

    Roman, Juan A.

    2014-01-01

    This presentation provides an overview of the activities National Aeronautics and Space Administration (NASA) is doing to encourage innovation across the agency. All information provided is available publicly.

  2. Responsive Innovation

    DEFF Research Database (Denmark)

    Pedersen, Carsten

    Although the importance of stakeholder networks has been recognized in recent years, a non-teleological model that incorporates their collective sensing into innovation processes has so far not been developed. Hence, this paper argues that traditional linear and sequential innovation models are i...... stakeholders engaged in the organization’s ongoing business activities collectively identify issues that central managers subsequently can resolve.......Although the importance of stakeholder networks has been recognized in recent years, a non-teleological model that incorporates their collective sensing into innovation processes has so far not been developed. Hence, this paper argues that traditional linear and sequential innovation models...

  3. Evaluation of the ROTAX spectrometer

    International Nuclear Information System (INIS)

    Tietze-Jaensch, H.; Schmidt, W.; Geick, R.

    1997-01-01

    After installation of the new-type rotating crystal analyser spectrometer ROTAX at ISIS, we report on practical experience and describe its current status. The rotating analyser technique works feasibly and reliably and provides an ultimate scan flexibility on a pulsed time-of-flight neutron spectrometer. The spinning analyser achieves a mulitplex advantage factor of ca. 50 without compromising the resolution of the instrument. Despite these instrument merits its individual beam position at ISIS has only an unsatisfactorily weak flux, thus hindering this instrument yet to become fully competitive with other high-performance neutron spectrometers based at high-flux reactors. However, we strongly recommend a ROTAX-type instrument to be emphasized when the instrumentation suite of the future European spallation source ESS will come under scrutiny. (orig.)

  4. How to Design a Spectrometer.

    Science.gov (United States)

    Scheeline, Alexander

    2017-10-01

    Designing a spectrometer requires knowledge of the problem to be solved, the molecules whose properties will contribute to a solution of that problem and skill in many subfields of science and engineering. A seemingly simple problem, design of an ultraviolet, visible, and near-infrared spectrometer, is used to show the reasoning behind the trade-offs in instrument design. Rather than reporting a fully optimized instrument, the Yin and Yang of design choices, leading to decisions about financial cost, materials choice, resolution, throughput, aperture, and layout are described. To limit scope, aspects such as grating blaze, electronics design, and light sources are not presented. The review illustrates the mixture of mathematical rigor, rule of thumb, esthetics, and availability of components that contribute to the art of spectrometer design.

  5. Optical analysis and performance verification on ALADIN spectrometers

    Science.gov (United States)

    Francou, Laurent; Rugi Grond, Elisabetta; Blum, Steffen; Voland, Christoph

    2017-11-01

    The Aeolus mission will take an innovative wind lidar called ALADIN (Atmospheric LAser Doppler INstrument) into space to measure wind profiles in the lowermost 30 km of the Earth's atmosphere. ALADIN is a direct detection wind lidar capable of using the backscatter signal from both molecular (Rayleigh-) and aerosol (Mie-) scattering to retrieve independent wind information. To achieve the mission goal, two separate spectrometers have been manufactured. The Rayleigh spectrometer is using a Fabry-Perot etalon with 2 paths and works like 2 narrow band filters. The detector measures the power reflected by the atmosphere for each thin band. The Mie spectrometer core is a Fizeau etalon. A CCD matrix measures directly the spectral response with a very fine resolution. For both etalons, the critical parameters are the FWHM (Full Width Half Maximum) and the Finesse. High optical quality and extremely narrow FWHM are needed to achieve mission performance but also request high quality system for the verification of those performances. The optical performance predictions, the verification philosophy and the test results are presented. The description of the different measurement setups including a system able to do spectral measurement with a resolution of some femtometers, the characteristic of the equipment and mathematical method used for calibration and to optimize the measurement accuracy are described. For the 2 spectrometers, a numerical model has been developed to analyse and predict the spectral response. The model and the results of the analysis are presented in the documents. The comparison between analysis and measurement results is discussed.

  6. use of x-ray fluorescence spectrometry to determine trace elements ...

    African Journals Online (AJOL)

    NIJOTECH

    here, an X-ray spectrometer was constructed and used to detect the presence of trace elements in graphite matrix by their K fluorescence X-ray lines. Equipment. The spectrometer consisted of an X-ray tube. (as primary source), a sample holder and a turn-table carrying the analyzer crystal and the detector, all mounted on ...

  7. Interfacing an aspiration ion mobility spectrometer to a triple quadrupole mass spectrometer

    International Nuclear Information System (INIS)

    Adamov, Alexey; Viidanoja, Jyrki; Kaerpaenoja, Esko; Paakkanen, Heikki; Ketola, Raimo A.; Kostiainen, Risto; Sysoev, Alexey; Kotiaho, Tapio

    2007-01-01

    This article presents the combination of an aspiration-type ion mobility spectrometer with a mass spectrometer. The interface between the aspiration ion mobility spectrometer and the mass spectrometer was designed to allow for quick mounting of the aspiration ion mobility spectrometer onto a Sciex API-300 triple quadrupole mass spectrometer. The developed instrumentation is used for gathering fundamental information on aspiration ion mobility spectrometry. Performance of the instrument is demonstrated using 2,6-di-tert-butyl pyridine and dimethyl methylphosphonate

  8. Design & Innovation

    DEFF Research Database (Denmark)

    Boelskifte, Per; Jørgensen, Ulrik

    2005-01-01

    The new design and innovation programme at DTU is challenging some of the standard concepts dominating most engineering educations. The programme, its background, context and basic educational ideas are presented and discussed in this paper. To build competences that match the need for innovative...

  9. Sensitive innovation

    DEFF Research Database (Denmark)

    Søndergaard, Katia Dupret

    Present paper discusses sources of innovation as heterogenic and at times intangible processes. Arguing for heterogeneity and intangibility as sources of innovation originates from a theoretical reading in STS and ANT studies (e.g. Callon 1986, Latour 1996, Mol 2002, Pols 2005) and from field work...

  10. Entrepreneurial Innovation

    NARCIS (Netherlands)

    Rigotti, L.; Ryan, M.; Vaithianathan, R.

    2001-01-01

    This paper constructs an equilibrium model of entrepreneurial innovation where individuals differ in their attitude toward uncertainty.Unlike previous models of innovation, the firm-formation process is endogenous.An entrepreneur, who owns residual profits, utilizes an uncertain technology and hires

  11. Innovation process

    DEFF Research Database (Denmark)

    Kolodovski, A.

    2006-01-01

    Purpose of this report: This report was prepared for RISO team involved in design of the innovation system Report provides innovation methodology to establish common understanding of the process concepts and related terminology The report does not includeRISO- or Denmark-specific cultural, econom...

  12. Pollution detection using the spectral fluorescent signatures (SFS technique

    Directory of Open Access Journals (Sweden)

    Mª Del Carmen Martín

    2014-06-01

    Full Text Available This work has been developed in the Applied Physics Department at the University of Vigo within the line of research based on the treatment of the degraded water by pollutants through the use of microalgae, reducing the emissions of greenhouse gases through the absorption of CO2 in the process and the reuse of biomass as biofuel. Remote sensing techniques have contributed to a great extent to the development of oil pollution monitoring systems. However, the available detection methods, mainly designed for spaceborne and airborne long distance inspection, are too expensive and complex to be used in an operational way by relatively unskilled personnel. In the framework of DEOSOM project (European AMPERA project, an innovative water monitoring method was proposed, in two steps: early oil spill detection using a portable shipborne laser-induced fluorescence LIDAR (LIF/LIDAR, and analysis of suspicious water samples in laboratory using the Spectral Fluorescent Signature (SFS technique. This work is focused on the second technique. This system aims to optimize the production of microalgae for biofuel and contaminant cleaning applications and was developed and tested in photo-bioreactors in the University of Vigo within the EnerBioAlgae project (SUDOE. In this project, the SFS technique was used as a diagnostic tool employing the fluorescence analyzer INSTANT-SCREENER M53UVC. The Spectral Fluorescence Signature technique (SFS is based on compounds fluorescence properties. The fluorescence intensity of a sample is measured at different excitation and emission wavelengths to produce a 3-dimensional fluorescence matrix, which can also be presented as a 2-dimensional color image where the color shows the intensity of the fluorescence. These matrices offer qualitative and quantitative information, since they can be useful for the identification of different substances from their characteristic excitation and emission spectra of fluorescence. They also

  13. MAPPING INNOVATION

    DEFF Research Database (Denmark)

    Thuesen, Christian Langhoff; Koch, Christian

    2011-01-01

    By adopting a theoretical framework from strategic niche management research (SNM) this paper presents an analysis of the innovation system of the Danish Construction industry. Theories within SNM look upon innovation in a sector as a socio-technical phenomenon and identifies three levels of socio......-technical interaction within which sectorial innovation can be explained. The analysis shows a multifaceted landscape of innovation around an existing regime, built in the existing ways of working and developing over generations. The regime is challenged from various niches and the sociotechnical landscape through...... trends as globalization. Three niches (Lean Construction, BIM and System Deliveries) are subject to a detailed analysis showing partly incompatible rationales and various degrees of innovation potential. The paper further discusses how existing policymaking operates in a number of tensions one being...

  14. Participatory Innovation

    DEFF Research Database (Denmark)

    Buur, Jacob; Matthews, Ben

    2008-01-01

    An increasing number of corporations engage with users in co-innovation of products and services. But there are a number of competing perspectives on how best to integrate these understandings into existing corporate innovation development processes. This paper maps out three of the dominant...... approaches, compares them in terms of goals, methods and basic philosophy, and shows how they may beneficially enrich one another. We will present an industrial innovation case that has been instrumental to the development of what we have termed ‘Participatory Innovation’. Based on this we will list...... the challenges such an approach sets to innovation management, and discuss research directions we see as fundamental to the development of the field of user-driven innovation. Udgivelsesdato: September...

  15. Responsible innovation

    CERN Document Server

    De Woot, Philippe

    2015-01-01

    Economic development is rooted in disruption, not in equilibrium. And a powerful engine of economic development is innovation; but is this innovation always for the common good? The dark side of the extraordinary dynamism of innovation lies precisely in its destructive power. If simply left to market forces, it could lead to social chaos and great human suffering. To face the challenges of our time, we must create the proper climate and culture to develop strong entrepreneurial drive. But, more than ever, we must give this entrepreneurial drive its ethical and societal dimensions. Responsible innovation means a more voluntary orientation towards the great problems of the 21st century, e.g. depletion of the planet's resources, rising inequality, and new scientific developments potentially threatening freedom, democracy and human integrity. We need to transform our ceaseless creativity into real progress for humankind. In this respect, the rapid development of social innovation opens the door for new methods an...

  16. Accidental Innovation

    DEFF Research Database (Denmark)

    Austin, Robert D.; Devin, Lee; Sullivan, Erin E.

    2012-01-01

    Historical accounts of human achievement suggest that accidents can play an important role in innovation. In this paper, we seek to contribute to an understanding of how digital systems might support valuable unpredictability in innovation processes by examining how innovators who obtain value from...... they incorporate accidents into their deliberate processes and arranged surroundings. By comparing makers working in varied conditions, we identify specific factors (e.g., technologies, characteristics of technologies) that appear to support accidental innovation. We show that makers in certain specified...... conditions not only remain open to accident but also intentionally design their processes and surroundings to invite and exploit valuable accidents. Based on these findings, we offer advice for the design of digital systems to support innovation processes that can access valuable unpredictability....

  17. A Micro-Cylindrical Ion Trap (µ-CIT) Micro-Mass Spectrometer Instrument System (µ-MSIS) for NASA Planetary Exploration

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal of this follow-on early stage innovation activity is to advance the development of new, extremely small, low power, and low cost "micro" mass spectrometer...

  18. A Micro-Cylindrical Ion Trap (µ-CIT) Micro-Mass Spectrometer Instrument System (µ-MSIS) for NASA Planetary Exploration

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal of this follow-on early stage innovation activity is to advance the development of new, extremely small, low power, and low cost “micro” mass spectrometer...

  19. Mid infrared MEMS FTIR spectrometer

    Science.gov (United States)

    Erfan, Mazen; Sabry, Yasser M.; Mortada, Bassem; Sharaf, Khaled; Khalil, Diaa

    2016-03-01

    In this work we report, for the first time to the best of our knowledge, a bulk-micromachined wideband MEMS-based spectrometer covering both the NIR and the MIR ranges and working from 1200 nm to 4800 nm. The core engine of the spectrometer is a scanning Michelson interferometer micro-fabricated using deep reactive ion etching (DRIE) technology. The spectrum is obtained using the Fourier Transform techniques that allows covering a very wide spectral range limited by the detector responsivity. The moving mirror of the interferometer is driven by a relatively large stroke electrostatic comb-drive actuator. Zirconium fluoride (ZrF4) multimode optical fibers are used to connect light between the white light source and the interferometer input, as well as the interferometer output to a PbSe photoconductive detector. The recorded signal-to-noise ratio is 25 dB at the wavelength of 3350 nm. The spectrometer is successfully used in measuring the absorption spectra of methylene chloride, quartz glass and polystyrene film. The presented solution provides a low cost method for producing miniaturized spectrometers in the near-/mid-infrared.

  20. Spectra of clinical CT scanners using a portable Compton spectrometer

    International Nuclear Information System (INIS)

    Duisterwinkel, H. A.; Abbema, J. K. van; Kawachimaru, R.; Paganini, L.; Graaf, E. R. van der; Brandenburg, S.; Goethem, M. J. van

    2015-01-01

    Purpose: Spectral information of the output of x-ray tubes in (dual source) computer tomography (CT) scanners can be used to improve the conversion of CT numbers to proton stopping power and can be used to advantage in CT scanner quality assurance. The purpose of this study is to design, validate, and apply a compact portable Compton spectrometer that was constructed to accurately measure x-ray spectra of CT scanners. Methods: In the design of the Compton spectrometer, the shielding materials were carefully chosen and positioned to reduce background by x-ray fluorescence from the materials used. The spectrum of Compton scattered x-rays alters from the original source spectrum due to various physical processes. Reconstruction of the original x-ray spectrum from the Compton scattered spectrum is based on Monte Carlo simulations of the processes involved. This reconstruction is validated by comparing directly and indirectly measured spectra of a mobile x-ray tube. The Compton spectrometer is assessed in a clinical setting by measuring x-ray spectra at various tube voltages of three different medical CT scanner x-ray tubes. Results: The directly and indirectly measured spectra are in good agreement (their ratio being 0.99) thereby validating the reconstruction method. The measured spectra of the medical CT scanners are consistent with theoretical spectra and spectra obtained from the x-ray tube manufacturer. Conclusions: A Compton spectrometer has been successfully designed, constructed, validated, and applied in the measurement of x-ray spectra of CT scanners. These measurements show that our compact Compton spectrometer can be rapidly set-up using the alignment lasers of the CT scanner, thereby enabling its use in commissioning, troubleshooting, and, e.g., annual performance check-ups of CT scanners

  1. Spectra of clinical CT scanners using a portable Compton spectrometer.

    Science.gov (United States)

    Duisterwinkel, H A; van Abbema, J K; van Goethem, M J; Kawachimaru, R; Paganini, L; van der Graaf, E R; Brandenburg, S

    2015-04-01

    Spectral information of the output of x-ray tubes in (dual source) computer tomography (CT) scanners can be used to improve the conversion of CT numbers to proton stopping power and can be used to advantage in CT scanner quality assurance. The purpose of this study is to design, validate, and apply a compact portable Compton spectrometer that was constructed to accurately measure x-ray spectra of CT scanners. In the design of the Compton spectrometer, the shielding materials were carefully chosen and positioned to reduce background by x-ray fluorescence from the materials used. The spectrum of Compton scattered x-rays alters from the original source spectrum due to various physical processes. Reconstruction of the original x-ray spectrum from the Compton scattered spectrum is based on Monte Carlo simulations of the processes involved. This reconstruction is validated by comparing directly and indirectly measured spectra of a mobile x-ray tube. The Compton spectrometer is assessed in a clinical setting by measuring x-ray spectra at various tube voltages of three different medical CT scanner x-ray tubes. The directly and indirectly measured spectra are in good agreement (their ratio being 0.99) thereby validating the reconstruction method. The measured spectra of the medical CT scanners are consistent with theoretical spectra and spectra obtained from the x-ray tube manufacturer. A Compton spectrometer has been successfully designed, constructed, validated, and applied in the measurement of x-ray spectra of CT scanners. These measurements show that our compact Compton spectrometer can be rapidly set-up using the alignment lasers of the CT scanner, thereby enabling its use in commissioning, troubleshooting, and, e.g., annual performance check-ups of CT scanners.

  2. Nuclear innovation in Saskatchewan: innovation

    Energy Technology Data Exchange (ETDEWEB)

    Alexander, N. [Sylvia Fedoruk Canadian Centre for Nuclear Innovation, Saskatoon, SK (Canada)

    2015-07-01

    This paper describes nuclear innovation in Saskatchewan. The first stage is the Canadian Institute for Science and Innovation Policy (CSIP) and how you have a successful discussion about a technically complex issue, understand what information people need in order to have an informed discussion, understand how to convey that information to those people in a constructive way.

  3. Participatory Innovation

    DEFF Research Database (Denmark)

    Buur, Jacob; Matthews, Ben

    2008-01-01

    An increasing number of corporations engage with users in co-innovation of products and services. But there are a number of competing perspectives on how best to integrate these understandings into existing corporate innovation development processes. This paper maps out three of the dominant appr...... the challenges such an approach sets to innovation management, and discuss research directions we see as fundamental to the development of the field of user-driven innovation. Udgivelsesdato: September......An increasing number of corporations engage with users in co-innovation of products and services. But there are a number of competing perspectives on how best to integrate these understandings into existing corporate innovation development processes. This paper maps out three of the dominant...... approaches, compares them in terms of goals, methods and basic philosophy, and shows how they may beneficially enrich one another. We will present an industrial innovation case that has been instrumental to the development of what we have termed ‘Participatory Innovation’. Based on this we will list...

  4. Injection Seeded Laser for Formaldehyde Differential Fluorescence Lidar

    Science.gov (United States)

    Schwemmer, G.; Yakshin, M.; Prasad, C.; Hanisco, T.; Mylapore, A. R.; Hwang, I. H.; Lee, S.

    2016-01-01

    We describe the design and development of an injection seeded Nd:YVO4 laser for use in a differential fluorescence lidar for measuring atmospheric formaldehyde profiles. A high repetition rate Q-switched laser is modified to accept injection seed input to spectrally narrow and tune the output. The third harmonic output is used to excite formaldehyde (HCHO) fluorescence when tuned to a HCHO absorption line. Spectral confirmation is made with the use of a photoacoustic cell and grating spectrometer.

  5. System for Gamma an X rays fluorescence spectrometric

    International Nuclear Information System (INIS)

    Alonso Abad, D.; Arista Romeu, E.; Bolanos Perez, L. and others

    1997-01-01

    A system for spectrometry of gamma or fluorescence X rays is presented. It sis composed by a Si(Li) semiconductors detector, a charge sensitive preamplifier, a high voltage power supply, a spectrometric amplifier and a monolithic 1024 channels multichannel analyzers or an IBM compatible 4096 channels add - on- card multichannel analyzer. The system can be configured as a 1024 or 4096 channels gamma or fluorescent X rays spectrometer

  6. Fluorescent Probes and Fluorescence (Microscopy Techniques — Illuminating Biological and Biomedical Research

    Directory of Open Access Journals (Sweden)

    Gregor P. C. Drummen

    2012-11-01

    Full Text Available Fluorescence, the absorption and re-emission of photons with longer wavelengths, is one of those amazing phenomena of Nature. Its discovery and utilization had, and still has, a major impact on biological and biomedical research, since it enables researchers not just to visualize normal physiological processes with high temporal and spatial resolution, to detect multiple signals concomitantly, to track single molecules in vivo, to replace radioactive assays when possible, but also to shed light on many pathobiological processes underpinning disease states, which would otherwise not be possible. Compounds that exhibit fluorescence are commonly called fluorochromes or fluorophores and one of these fluorescent molecules in particular has significantly enabled life science research to gain new insights in virtually all its sub-disciplines: Green Fluorescent Protein. Because fluorescent proteins are synthesized in vivo, integration of fluorescent detection methods into the biological system via genetic techniques now became feasible. Currently fluorescent proteins are available that virtually span the whole electromagnetic spectrum. Concomitantly, fluorescence imaging techniques were developed, and often progress in one field fueled innovation in the other. Impressively, the properties of fluorescence were utilized to develop new assays and imaging modalities, ranging from energy transfer to image molecular interactions to imaging beyond the diffraction limit with super-resolution microscopy. Here, an overview is provided of recent developments in both fluorescence imaging and fluorochrome engineering, which together constitute the “fluorescence toolbox” in life science research.

  7. Design & Innovation

    DEFF Research Database (Denmark)

    Boelskifte, Per; Jørgensen, Ulrik

    2005-01-01

    The new design and innovation programme at DTU is challenging some of the standard concepts dominating most engineering educations. The programme, its background, context and basic educational ideas are presented and discussed in this paper. To build competences that match the need for innovative...... and design oriented engineers in industry and society has turned out to challenge a number of the standard – and often taken for granted – concepts in engineering education still dominated world wide by rather strict norms and concepts of learning that do not challenge the students creativity and innovative...

  8. Compact Spectrometers Based on Linear Variable Filters

    Data.gov (United States)

    National Aeronautics and Space Administration — Demonstrate a linear-variable spectrometer with an H2RG array. Linear Variable Filter (LVF) spectrometers provide attractive resource benefits – high optical...

  9. Design and Elementary Evaluation of a Highly-Automated Fluorescence-Based Instrument System for On-Site Detection of Food-Borne Pathogens

    Directory of Open Access Journals (Sweden)

    Zhan Lu

    2017-02-01

    Full Text Available A simple, highly-automated instrument system used for on-site detection of foodborne pathogens based on fluorescence was designed, fabricated, and preliminarily tested in this paper. A corresponding method has been proved effective in our previous studies. This system utilizes a light-emitting diode (LED to excite fluorescent labels and a spectrometer to record the fluorescence signal from samples. A rotation stage for positioning and switching samples was innovatively designed for high-throughput detection, ten at most in one single run. We also developed software based on LabVIEW for data receiving, processing, and the control of the whole system. In the test of using a pure quantum dot (QD solution as a standard sample, detection results from this home-made system were highly-relevant with that from a well-commercialized product and even slightly better reproducibility was found. And in the test of three typical kinds of food-borne pathogens, fluorescence signals recorded by this system are highly proportional to the variation of the sample concentration, with a satisfied limit of detection (LOD (nearly 102–103 CFU·mL−1 in food samples. Additionally, this instrument system is low-cost and easy-to-use, showing a promising potential for on-site rapid detection of food-borne pathogens.

  10. First results from the MAPS spectrometer at ISIS

    International Nuclear Information System (INIS)

    Frost, C.D.; Perring, T.G.

    2001-01-01

    The scientific commissioning of MAPS, the new state-of-the-art neutron scattering instrument at ISIS, has just begun. The design of MAPS has been optimised for studies of coherent excitations in single-crystals. The principal innovation is the use of position sensitive detectors that provide close to continuos coverage over a large solid angle detector array in the forward direction. The technical description of the spectrometer is presented, and examples from the first scientific experiments are used to illustrate how the position sensitive detectors coupled with easy-to-use visualisation software is already beginning to have an impact in the measurement of excitations in single crystals. (author)

  11. Photostability effect of silica nanoparticles encapsulated fluorescence dye

    Science.gov (United States)

    Ahmad, Atiqah; Zakaria, Nor Dyana; Razak, Khairunisak Abdul

    2017-12-01

    Fluorescence dyes are based on small organic molecules have become of interest in chemical biology and widely used for cell and intracellular imaging. However, fluorescence dyes have limitations such as photo bleaching, poor photochemical stability and has a short Stokes shift. It is less valuable for long-term cell tracking strategies and has very short lifetime. In order to overcome the problems, dye-incorporated nanomaterials become of interest. Nanomaterials encapsulation provides a protection layer around the fluorescence dye which improves the stability of fluorescence dye. In this study, silica nanoparticles encapsulated with 1,1%-dioctadecyl-3,3,3%,3%-tetramethylindocarbocyanine perchlorate (Dil) was successfully synthesised by using micelle entrapment method to investigate the effect of encapsulation of nanoparticles towards the properties of fluorescent dye. The synthesised nanoparticles (SiDil) was characterised by particle size analyser, Transmission Electron Microscopy (TEM), UV-Vis spectrometer and Fluorescent spectrometer. Observation using TEM showed spherical shape of nanoparticles with 53 nm diameter. Monodispersed and well nanoparticles distribution was confirmed by low polydispersity index of 0.063 obtained by particle size analyser. Furthermore, the photoluminescence properties of the SiDil were evaluated and compared with bare Dil dye. Both SiDil and bare Dil was radiated under 200 W of Halogen lamp for 60 minutes and the absorbance intensity was measured using UV-Vis spectrometer. The result showed more stable absorbance intensity for SiDil compared to bare Dil dye, which indicated that Si nanoparticles encapsulation improved the photostability property.

  12. Innovation Awards

    Science.gov (United States)

    EPA promotes environmental stewardship by recognizing innovators in schools, communities and businesses in categories such as environmental education, green chemistry, smart growth, green power, and reducing air pollution and climate change impacts.

  13. Online Innovation

    DEFF Research Database (Denmark)

    Vujovic, Sladjana; Ulhøi, John Parm

    2008-01-01

    on proprietary knowledge. Design/methodology/approach - The paper borrows from the theory of communities-of-practice, which takes into account social relations, contacts, and the transfer and incorporation of knowledge. Open source innovation is not the exclusive preserve of computer nerds, but also has...... implications for existing software manufacturers. The paper therefore includes the case of IBM, a company which has successfully integrated this new and more open way of collaboration into its business model. Findings - The paper concludes that online computer-based innovation fundamentally challenges current...... for practitioners directly involved in innovation and product development. Originality/value - This paper develops a conceptual framework for understanding product development based on non-proprietary knowledge, which cannot be adequately accounted for by traditional corporate innovation theory alone....

  14. Reconsidering Innovation

    DEFF Research Database (Denmark)

    Vaaben, Nana Katrine

    Innovation and reforms seem to be on the agenda everywhere, not least in political attempts to reorganize the public sector in ways that are supposed to enable our welfare societies to survive economic turmoil and sinister future prognosis. This paper examines how classical anthropological theories...... and debates about change, myths, and othering can help us rethink theoretical approaches to innovation in organizational studies, and the concern is especially to consider the implications that our “innovation myths” can have for public employees and the valuation their work. The argument in the paper...... is that innovation is better understood as a perspective (a prism) than as a product or a process, and that this perspective tends to “other” people who’s work is not visible as a positive asset in a budget, but may be visible as a positive contribution in people’s lives. The way in which that point is made...

  15. MAPPING INNOVATION

    DEFF Research Database (Denmark)

    Thuesen, Christian Langhoff; Koch, Christian

    2011-01-01

    By adopting a theoretical framework from strategic niche management research (SNM) this paper presents an analysis of the innovation system of the Danish Construction industry. The analysis shows a multifaceted landscape of innovation around an existing regime, built around existing ways of working...... and developed over generations. The regime is challenged from various niches and the socio-technical landscape through trends as globalization. Three niches (Lean Construction, BIM and System Deliveries) are subject to a detailed analysis showing partly incompatible rationales and various degrees of innovation...... potential. The paper further discusses how existing policymaking operates in a number of tensions one being between government and governance. Based on the concepts from SNM the paper introduces an innovation map in order to support the development of meta-governance policymaking. By mapping some...

  16. Participatory Innovation

    DEFF Research Database (Denmark)

    Buur, Jacob; Matthews, Ben

    In this paper we discuss the potential for Participatory Design (PD) to make a fundamental contribution to the business-oriented field of user-driven innovation, taking note of where we find PD can best benefit from interaction with this other field. We examine some of the challenges that must be...... be addressed if PD is to contribute to innovation processes in companies. We conclude by presenting a research agenda comprising of six promising topics to shape a new discipline of Participatory Innovation.......In this paper we discuss the potential for Participatory Design (PD) to make a fundamental contribution to the business-oriented field of user-driven innovation, taking note of where we find PD can best benefit from interaction with this other field. We examine some of the challenges that must...

  17. Innovation networks

    OpenAIRE

    Ahrweiler, Petra; Keane, Mark T.

    2013-01-01

    This paper advances a framework for modeling the component interactions between cognitive and social aspects of scientific creativity and technological innovation. Specifically, it aims to characterize Innovation Networks; those networks that involve the interplay of people, ideas and organizations to create new, technologically feasible, commercially-realizable products, processes and organizational structures. The tri-partite framework captures networks of ideas (Concept Level), people (Ind...

  18. Leadership Innovations

    Science.gov (United States)

    1993-04-01

    leadership " and " leadership in innovation." 3 THEORY , AS AN INSTRUMENT OF ANALYSIS FOR INNOVATION IN LEADERSHIP There are many...attributes of a leader.𔃺 Attempts to define leadership usually contrast it with "followship", management ," or sometimes - with ’beadship."’" These...plausible theory . - . . . -. - -- Nevertheless, some authors consider, and I agree, that there is no true leadership theory because existing

  19. Electron spectrometer for gas-phase spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Bozek, J.D.; Schlachter, A.S. [Ernest Orlando Lawrence Berkeley National Lab., CA (United States)

    1997-04-01

    An electron spectrometer for high-resolution spectroscopy of gaseous samples using synchrotron radiation has been designed and constructed. The spectrometer consists of a gas cell, cylindrical electrostatic lens, spherical-sector electron energy analyzer, position-sensitive detector and associated power supplies, electronics and vacuum pumps. Details of the spectrometer design are presented together with some representative spectra.

  20. Quantum Dot Spectrometer (GSFC IRAD)

    Data.gov (United States)

    National Aeronautics and Space Administration — We are developing an ultra-compact, low mass, low-cost, yet high resolution, multispectral imager based on an innovative quantum dot array concept. The quantum dot...

  1. Airborne gamma ray spectrometer surveying

    International Nuclear Information System (INIS)

    1991-01-01

    The International Atomic Energy Agency (IAEA) in its role as collector and disseminator of information on nuclear techniques has long had an interest in gamma ray spectrometer methods and has published a number of Technical Reports on various aspects of the subject. At an Advisory Group Meeting held in Vienna in November 1986 to review appropriate activities the IAEA could take following the Chernobyl accident, it was recommended that preparation begin on a new Technical Report on airborne gamma ray spectrometer surveying, taking into account the use of the technique for environmental monitoring as well as for nuclear emergency response requirements. Shortly thereafter the IAEA became the lead organization in the Radioelement Geochemical Mapping section of the International Geological Correlation Programme/United Nations Educational, Scientific and Cultural Organization (UNESCO) Project on International Geochemical Mapping. These two factors led to the preparation of the present Technical Report. 18 figs, 4 tabs

  2. Heavy-ion-spectrometer system

    International Nuclear Information System (INIS)

    1982-05-01

    LBL safety policy (Pub 300 Appendix E) states that every research operation with a Class A risk potential (DOE 5484.1) should identify potentially hazardous procedures associated with the operation and develop methods for accomplishing the operation safely without personnel injury or property damage. The rules and practices that management deems to be minimally necessary for the safe operations of the Heavy Ion Spectrometer System (HISS) in the Bevatron Experimental Hall (51B) are set forth in this Operation Safety Procedures

  3. Heavy-ion-spectrometer system

    Energy Technology Data Exchange (ETDEWEB)

    1982-05-01

    LBL safety policy (Pub 300 Appendix E) states that every research operation with a Class A risk potential (DOE 5484.1) should identify potentially hazardous procedures associated with the operation and develop methods for accomplishing the operation safely without personnel injury or property damage. The rules and practices that management deems to be minimally necessary for the safe operations of the Heavy Ion Spectrometer System (HISS) in the Bevatron Experimental Hall (51B) are set forth in this Operation Safety Procedures (OSP).

  4. The HISS spectrometer at LBL

    International Nuclear Information System (INIS)

    Greiner, D.

    1981-01-01

    The Heavy Ion Spectrometer System at LBL is designed to be a general purpose experimental work bench able to support a wide variety of experiments. Our philosophy is to provide instruments capable of investigating, with multi-particle sensitivity, a large portion of phase space. We have not chosen a particular region such as mid-rapidity or projectile frame, but instead, have made sure that the magnet and the instrumentation allow these choices as well as many others. (orig.)

  5. The superconducting kaon spectrometer - SKS

    International Nuclear Information System (INIS)

    Fukuda, T.; Takahashi, T.; Aoki, K.; Doi, Y.; Kondo, Y.; Makida, Y.; Nomachi, M.; Noumi, H.; Sasaki, O.; Shintomi, T.; Bhang, H.; Park, H.; Youn, M.; Yu, H.; Gavrilov, Y.; Ajimura, S.; Kishimoto, T.; Ohkusu, A.; Shinkai, N.; Maeda, K.; Sawafta, R.

    1995-01-01

    A superconducting kaon spectrometer has been installed in the north experimental hall of the KEK 12-GeV proton synchrotron. The spectrometer was designed to serve for nuclear physics experiments with meson beams in the 1 GeV/c region, particular emphasis being laid on study of Λ-hypernuclei via (π + ,K + ) reactions. In order to obtain Λ-hypernuclear data with better statistics and energy resolution, it was designed to have a good momentum resolution of 0.1% FWHM and a large acceptance of 100 msr. It consists of a large superconducting dipole magnet, tracking chambers, and trigger counters that can efficiently select kaons from large background of pions and protons. The overall energy resolution for scattering is realized together with a beam-line spectrometer in the K6 beam line, the momentum resolution of which was also designed to be better than 0.1% FWHM. A good energy resolution of better than 2 MeV FWHM has been confirmed in π - - 12 C elastic scattering and in the (π + ,K + ) reaction on 12 C. (orig.)

  6. Oxford MDM-2 magnetic spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Pringle, D.M.; Catford, W.N.; Winfield, J.S.; Lewis, D.G.; Jelley, N.A.; Allen, K.W.; Coupland, J.H.

    1986-05-01

    A new high resolution magnetic spectrometer - the Oxford MDM-2 spectrometer - has been designed, installed and tested. The layout of the magnetic elements is in the order: entrance sextupole and multipole, gradient-field dipole and exit multipole. The device has a ''normal'' focal plane, and the 1.6 m radius dipole magnet has a maximum mass-energy product of 315 MeV amu. At the maximum solid angle of 8 msr, the ratio of energies that can be accepted by the spectrometer (Esub(max)/Esub(min)) is 1.31. Precise measurements have been performed on the magnetic elements. The dipole magnet has very low hysteresis and field integral errors that amount to less than 1 part in 10/sup 4/. After some in situ modifications the field distributions of the magnets closely approximated the original design specifications. On-line tests with various ion-beams have revealed the optimum setting for each element. These are close to theoretical predictions from the program RAYTRACE, incorporating the parameterised results of the magnetic measurements. An aberration limited resolution (E/..delta..E) of greater than 3000 has been observed at 8 msr solid angle.

  7. A NMR spectrometer for educational purposes

    International Nuclear Information System (INIS)

    Colnago, Luiz A.; Torre Neto, Andre

    1991-01-01

    A NMR spectrometer has been constructed for educational purposes, such as teaching of the technique basic principles and instrumentation. The spectrometer has been designed with a minimum number of components so that the students may have acquittance with both the spectrometer, through block diagrams, and the small numbers of existent components . The device was based on a 0.t Tesla magnet from the continuous wave spectrometer (E M 300 - Varian) existent at the Instituto Militar de Engenharia, and it is expected to facilitate the comprehension of the commercial spectrometers

  8. A quinoline based pH sensitive ratiometric fluorescent sensor ...

    Indian Academy of Sciences (India)

    Fluorescence measurements were performed on a Hitachi F7000 spectrofluorimeter. Mass spectra measurement was carried out by Waters Xevo G2-. S QTof Mass Spectrometer. pH measurements were carried out using Orion 3-Star Plus pH Benchtop Meter. 2.2 Synthesis. The compound 1 was synthesized by stirring an.

  9. Use of X-Ray Fluorescence Spectrometry to Determine Trace ...

    African Journals Online (AJOL)

    This paper deals with application of X-ray fluorescence spectrometry for the detection of trace elements in graphic. An X-ray spectrometer was constructed and used to carry out measurements on graphite spheres impregnated with different chemical elements. The intensities of the lines of these trace elements, as function of ...

  10. X-ray emission spectroscopy. X-ray fluorescence

    International Nuclear Information System (INIS)

    Despujols, J.

    1992-01-01

    Principles of X-ray emission spectrometry are first recalled, then wave-length dispersive and energy dispersive X-ray fluorescence spectrometer are described. They are essentially designed for qualitative and quantitative analysis of elements (Z>10). Sample preparation, calibration, corrections, interferences, accuracy are reviewed. Examples of use in different industries are given. (71 refs.)

  11. Fluorescence detection: SPIE volume 743

    International Nuclear Information System (INIS)

    Menzel, E.R.

    1987-01-01

    This book contains proceedings arranged into four sessions. They are: Fluorescence spectroscopic techniques; Fluorescence in analysis and materials characterization; Fluorescence in medicine and biochemistry; and Fluorescence in criminalistics

  12. Fluorescence detection: SPIE volume 743

    Energy Technology Data Exchange (ETDEWEB)

    Menzel, E.R.

    1987-01-01

    This book contains proceedings arranged into four sessions. They are: Fluorescence spectroscopic techniques; Fluorescence in analysis and materials characterization; Fluorescence in medicine and biochemistry; and Fluorescence in criminalistics.

  13. Software Innovation

    DEFF Research Database (Denmark)

    Rose, Jeremy

      Innovation is the forgotten key to modern systems development - the element that defines the enterprising engineer, the thriving software firm and the cutting edge software application.  Traditional forms of technical education pay little attention to creativity - often encouraging overly ratio...... out the new field of software innovation. It organizes the existing scientific research into eight simple heuristics - guiding principles for organizing a system developer's work-life so that it focuses on innovation.......  Innovation is the forgotten key to modern systems development - the element that defines the enterprising engineer, the thriving software firm and the cutting edge software application.  Traditional forms of technical education pay little attention to creativity - often encouraging overly...... rationalistic ways of thinking which stifle the ability to innovate. Professional software developers are often drowned in commercial drudgery and overwhelmed by work pressure and deadlines. The topic that will both ensure success in the market and revitalize their work lives is never addressed. This book sets...

  14. Ion mobility spectrometer / mass spectrometer (IMS-MS).

    Energy Technology Data Exchange (ETDEWEB)

    Hunka Deborah Elaine; Austin, Daniel E.

    2005-07-01

    The use of Ion Mobility Spectrometry (IMS) in the Detection of Contraband Sandia researchers use ion mobility spectrometers for trace chemical detection and analysis in a variety of projects and applications. Products developed in recent years based on IMS-technology include explosives detection personnel portals, the Material Area Access (MAA) checkpoint of the future, an explosives detection vehicle portal, hand-held detection systems such as the Hound and Hound II (all 6400), micro-IMS sensors (1700), ordnance detection (2500), and Fourier Transform IMS technology (8700). The emphasis to date has been on explosives detection, but the detection of chemical agents has also been pursued (8100 and 6400). Combining Ion Mobility Spectrometry (IMS) with Mass Spectrometry (MS) is described. The IMS-MS combination overcomes several limitations present in simple IMS systems. Ion mobility alone is insufficient to identify an unknown chemical agent. Collision cross section, upon which mobility is based, is not sufficiently unique or predictable a priori to be able to make a confident peak assignment unless the compounds present are already identified. Molecular mass, on the other hand, is much more readily interpreted and related to compounds. For a given compound, the molecular mass can be determined using a pocket calculator (or in one's head) while a reasonable value of the cross-section might require hours of computation time. Thus a mass spectrum provides chemical specificity and identity not accessible in the mobility spectrum alone. In addition, several advanced mass spectrometric methods, such as tandem MS, have been extensively developed for the purpose of molecular identification. With an appropriate mass spectrometer connected to an ion mobility spectrometer, these advanced identification methods become available, providing greater characterization capability.

  15. Ion Mobility Spectrometer / Mass Spectrometer (IMS-MS)

    Energy Technology Data Exchange (ETDEWEB)

    Hunka, Deborah E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Austin, Daniel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2005-10-01

    The use of Ion Mobility Spectrometry (IMS)in the Detection of Contraband Sandia researchers use ion mobility spectrometers for trace chemical detection and analysis in a variety of projects and applications. Products developed in recent years based on IMS-technology include explosives detection personnel portals, the Material Area Access (MAA) checkpoint of the future, an explosives detection vehicle portal, hand-held detection systems such as the Hound and Hound II (all 6400), micro-IMS sensors (1700), ordnance detection (2500), and Fourier Transform IMS technology (8700). The emphasis to date has been on explosives detection, but the detection of chemical agents has also been pursued (8100 and 6400).

  16. Everyday Innovation

    DEFF Research Database (Denmark)

    Lippke, Lena; Wegener, Charlotte

    2014-01-01

    activities in which teachers succeed to balance continuities and discontinuities. Studying innovation as a balance between change and stability thus involves emerging, negotiated processes of learning and participation in everyday practices where people talk, interact and conduct their work and studies......Purpose – The purpose of this paper is to explore how vocational teachers’ everyday practices can constitute innovative learning spaces that help students to experience engagement and commitment towards education and thus increase their possibilities for completing their studies despite notable...... difficulties. Design/methodology/approach – Based on two ethnographic field studies, we analyse vocational teaching situations in which teachers and students engage in daily remaking of the vocational educational training practice. It is argued that these everyday situations can be understood as innovative...

  17. Collaborative innovation

    DEFF Research Database (Denmark)

    Timenes Laugen, Bjørge; Lassen, Astrid Heidemann

    2011-01-01

    Industry and academia alike are increasingly becoming aware of the fact that innovation does not take place in isolated cells or functions within the firm. Although the idea of involving internal and external actors in the new product development (NPD) process is not new, the knowledge about...... the benefits and pitfalls is still limited. This paper aims to contribute to refining the concept of open innovation, by investigating how strategic priorities influence the degree of external and internal involvement in the NPD process, moderated by contextual factors. The results indicate that suppliers...... are heavily involved in the NPD process in firms in B2C markets aiming at increasing the innovation volume. For B2B companies the reverse picture emerges. However, when the aim is to increase the radicality of new products, suppliers and customers are heavily involved for firms in B2B markets....

  18. Open innovation

    DEFF Research Database (Denmark)

    West, Joel; Bogers, Marcel

    2017-01-01

    Interest in open innovation (OI) as a field of research has grown exponentially since the phrase was coined by Chesbrough in his 2003 book, with numerous articles, special issues, books, and conference sessions. Various reviews of the literature have summarized prior work, offered new frameworks......, and identified opportunities for future research. Here we summarize these opportunities, which include more research on outbound OI, the role of open innovation in services, and network forms of collaboration such as consortia, communities, ecosystems, and platforms. Research should also examine the use of OI...... is rejected, abandoned, or fails. Finally, we consider how OI can be better linked to prior theoretical research, including topics such as absorptive capacity, user innovation, resources, dynamic capabilities, business models, and the definition of the firm....

  19. Reconsidering Innovation

    DEFF Research Database (Denmark)

    Vaaben, Nana Katrine

    Innovation og reformer er på dagsordenen allevegne, ikke mindst i politiske forsøg på at reorganisere den offentlige sektor for at få velfærdssamfundet til at kunne overleve økonomisk tumult og dystre fremtidsprognoser. Dette papir undersøger, hvordan klassiske antropologiske teorier og debatter om...... forandring og myter kan hjælpe os med at genoverveje teoretiske forståelser af innovation i organisatoriske studier. I særlig grad sættes der fokus på de implikationer som vores "innovationsmyte" kan have for offentligt ansatte og værdsættelsen af deres arbejde. Analysens argument er, at innovation ikke skal...

  20. Responsive Innovation

    DEFF Research Database (Denmark)

    Pedersen, Carsten

    In dynamic environments, competitive advantage lies in developing useful knowledge from continuous streams of unstructured and ambiguous data. Frontline employees and certain groups of customers are often the first to sense emerging issues of strate-gic importance due to their experiential insights...... of the firm’s daily operations. Yet, they are rarely asked to provide updated information about critical issues. The present paper seeks to conceptually develop the notion of responsive innovation, by drawing on literary streams concerning collective sensing, strategic issue diagnosis and integra......-tive strategy within a micro foundations perspective. It is posited that companies should root their innovation processes in the collective sensing of frontline-employees and customers that operate around the organizational periphery. This frames the con-cept of responsive innovation, where individuals engaged...

  1. Semiconductor X-ray spectrometers

    International Nuclear Information System (INIS)

    Muggleton, A.H.F.

    1978-02-01

    An outline is given of recent developments in particle and photon induced x-ray fluorescence (XRF) analysis. Following a brief description of the basic mechanism of semiconductor detector operation a comparison is made between semiconductor detectors, scintillators and gas filled proportional devices. Detector fabrication and cryostat design are described in more detail and the effects of various device parameters on system performance, such as energy resolution, count rate capability, efficiency, microphony, etc. are discussed. The main applications of these detectors in x-ray fluorescence analysis, electron microprobe analysis, medical and pollution studies are reviewed

  2. Effektiv innovation

    DEFF Research Database (Denmark)

    Søndergaard, Katia Dupret; Brandi, Ulrik

    2011-01-01

    Er det vækst og udvikling eller åbenhed, videnudvikling, netværk, leg og innovation? Eller er det prisregulering, tilpasning og stærk styring, som skal gøre universiteterne til førende drivkræfter for dansk vækst?......Er det vækst og udvikling eller åbenhed, videnudvikling, netværk, leg og innovation? Eller er det prisregulering, tilpasning og stærk styring, som skal gøre universiteterne til førende drivkræfter for dansk vækst?...

  3. The Alpha Magnetic Spectrometer (AMS)

    CERN Document Server

    Alcaraz, J; Ambrosi, G; Anderhub, H; Ao, L; Arefev, A; Azzarello, P; Babucci, E; Baldini, L; Basile, M; Barancourt, D; Barão, F; Barbier, G; Barreira, G; Battiston, R; Becker, R; Becker, U; Bellagamba, L; Bene, P; Berdugo, J; Berges, P; Bertucci, B; Biland, A; Bizzaglia, S; Blasko, S; Bölla, G; Boschini, M; Bourquin, Maurice; Brocco, L; Bruni, G; Buénerd, M; Burger, J D; Burger, W J; Cai, X D; Camps, C; Cannarsa, P; Capell, M; Casadei, D; Casaus, J; Castellini, G; Cecchi, C; Chang, Y H; Chen, H F; Chen, H S; Chen, Z G; Chernoplekov, N A; Tzi Hong Chiueh; Chuang, Y L; Cindolo, F; Commichau, V; Contin, A; Crespo, P; Cristinziani, M; Cunha, J P D; Dai, T S; Deus, J D; Dinu, N; Djambazov, L; Dantone, I; Dong, Z R; Emonet, P; Engelberg, J; Eppling, F J; Eronen, T; Esposito, G; Extermann, P; Favier, Jean; Fiandrini, E; Fisher, P H; Flügge, G; Fouque, N; Galaktionov, Yu; Gervasi, M; Giusti, P; Grandi, D; Grimm, O; Gu, W Q; Hangarter, K; Hasan, A; Hermel, V; Hofer, H; Huang, M A; Hungerford, W; Ionica, M; Ionica, R; Jongmanns, M; Karlamaa, K; Karpinski, W; Kenney, G; Kenny, J; Kim, W; Klimentov, A; Kossakowski, R; Koutsenko, V F; Kraeber, M; Laborie, G; Laitinen, T; Lamanna, G; Laurenti, G; Lebedev, A; Lee, S C; Levi, G; Levchenko, P M; Liu, C L; Liu, H T; Lopes, I; Lu, G; Lü, Y S; Lübelsmeyer, K; Luckey, D; Lustermann, W; Maña, C; Margotti, A; Mayet, F; McNeil, R R; Meillon, B; Menichelli, M; Mihul, A; Mourao, A; Mujunen, A; Palmonari, F; Papi, A; Park, I H; Pauluzzi, M; Pauss, Felicitas; Perrin, E; Pesci, A; Pevsner, A; Pimenta, M; Plyaskin, V; Pozhidaev, V; Postolache, V; Produit, N; Rancoita, P G; Rapin, D; Raupach, F; Ren, D; Ren, Z; Ribordy, M; Richeux, J P; Riihonen, E; Ritakari, J; Röser, U; Roissin, C; Sagdeev, R; Sartorelli, G; Schwering, G; Scolieri, G; Seo, E S; Shoutko, V; Shoumilov, E; Siedling, R; Son, D; Song, T; Steuer, M; Sun, G S; Suter, H; Tang, X W; Ting, Samuel C C; Ting, S M; Tornikoski, M; Torsti, J; Ulbricht, J; Urpo, S; Usoskin, I; Valtonen, E; Vandenhirtz, J; Velcea, F; Velikhov, E P; Verlaat, B; Vetlitskii, I; Vezzu, F; Vialle, J P; Viertel, Gert M; Vitè, Davide F; Gunten, H V; Wallraff, W; Wang, B C; Wang, J Z; Wang, Y H; Wiik, K; Williams, C; Wu, S X; Xia, P C; Yan, J L; Yan, L G; Yang, C G; Yang, M; Ye, S W; Yeh, P; Xu, Z Z; Zhang, H Y; Zhang, Z P; Zhao, D X; Zhu, G Y; Zhu, W Z; Zhuang, H L; Zichichi, A; Zimmermann, B

    2002-01-01

    The Alpha Magnetic Spectrometer (AMS) is a large acceptance (0.65 sr m sup 2) detector designed to operate in the International Space Station (ISS) for three years. The purposes of the experiment are to search for cosmic antimatter and dark matter and to study the composition and energy spectrum of the primary cosmic rays. A 'scaled-down' version has been flown on the Space Shuttle Discovery for 10 days in June 1998. The complete AMS is programmed for installation on the ISS in October 2003 for an operational period of 3 yr. This contribution reports on the experimental configuration that will be installed on the ISS.

  4. The Alpha Magnetic Spectrometer (ams)

    Science.gov (United States)

    Ionica, Maria

    2004-01-01

    The Alpha Magnetic Spectrometer (AMS), once installed on the International Space Station will provide precise measurements of the cosmic ray spectra up to TeV energy range, and will search for cosmological antimatter and missing matter. A prototype version of the detector was operated successfully on the space shuttle Discovery in June 1998 (STS-91). Here we briefly report on the design of the AMS apparatus and present the results of the measurements of the fluxes of proton, electron, positron and helium from the STS-91 flight.

  5. Portable neutron spectrometer and dosimeter

    Science.gov (United States)

    Waechter, D.A.; Erkkila, B.H.; Vasilik, D.G.

    The disclosure relates to a battery operated neutron spectrometer/dosimeter utilizing a microprocessor, a built-in tissue equivalent LET neutron detector, and a 128-channel pulse height analyzer with integral liquid crystal display. The apparatus calculates doses and dose rates from neutrons incident on the detector and displays a spectrum of rad or rem as a function of keV per micron of equivalent tissue and also calculates and displays accumulated dose in millirads and millirem as well as neutron dose rates in millirads per hour and millirem per hour.

  6. New spectrometer for charged particles

    International Nuclear Information System (INIS)

    Wajsfelner, Rene

    1970-02-01

    This thesis is devoted to the study and development of an electrostatic spectrometer which is not only more accurate for the determination of size distributions of electrically charged radio-active atmospheric aerosols, but which can also be used for measuring the grain-size distribution of any cloud of particles which will previously have been charged according to a known, reproducible law. An experimental study has been made of the development of this precipitator and also of its calibration. The electrical charge on spherical polystyrene latex particles suspended in air by atomization has been studied; a theoretical explanation of these results is put forward. (author) [fr

  7. The Alpha Magnetic Spectrometer (AMS)

    International Nuclear Information System (INIS)

    Alcaraz, J.; Alpat, B.; Ambrosi, G.; Anderhub, H.; Ao, L.; Arefiev, A.; Azzarello, P.; Babucci, E.; Baldini, L.; Basile, M.; Barancourt, D.; Barao, F.; Barbier, G.; Barreira, G.; Battiston, R.; Becker, R.; Becker, U.; Bellagamba, L.; Bene, P.; Berdugo, J.; Berges, P.; Bertucci, B.; Biland, A.; Bizzaglia, S.; Blasko, S.; Boella, G.; Boschini, M.; Bourquin, M.; Brocco, L.; Bruni, G.; Buenerd, M.; Burger, J.D.; Burger, W.J.; Cai, X.D.; Camps, C.; Cannarsa, P.; Capell, M.; Casadei, D.; Casaus, J.; Castellini, G.; Cecchi, C.; Chang, Y.H.; Chen, H.F.; Chen, H.S.; Chen, Z.G.; Chernoplekov, N.A.; Chiueh, T.H.; Chuang, Y.L.; Cindolo, F.; Commichau, V.; Contin, A.; Crespo, P.; Cristinziani, M.; Cunha, J.P. da; Dai, T.S.; Deus, J.D.; Dinu, N.; Djambazov, L.; DAntone, I.; Dong, Z.R.; Emonet, P.; Engelberg, J.; Eppling, F.J.; Eronen, T.; Esposito, G.; Extermann, P.; Favier, J.; Fiandrini, E.; Fisher, P.H.; Fluegge, G.; Fouque, N.; Galaktionov, Yu.; Gervasi, M.; Giusti, P.; Grandi, D.; Grimm, O.; Gu, W.Q.; Hangarter, K.; Hasan, A.; Hermel, V.; Hofer, H.; Huang, M.A.; Hungerford, W.; Ionica, M.; Ionica, R.; Jongmanns, M.; Karlamaa, K.; Karpinski, W.; Kenney, G.; Kenny, J.; Kim, W.; Klimentov, A.; Kossakowski, R.; Koutsenko, V.; Kraeber, M.; Laborie, G.; Laitinen, T.; Lamanna, G.; Laurenti, G.; Lebedev, A.; Lee, S.C.; Levi, G.; Levtchenko, P.; Liu, C.L.; Liu, H.T.; Lopes, I.; Lu, G.; Lu, Y.S.; Luebelsmeyer, K.; Luckey, D.; Lustermann, W.; Mana, C.; Margotti, A.; Mayet, F.; McNeil, R.R.; Meillon, B.; Menichelli, M.; Mihul, A.; Mourao, A.; Mujunen, A.; Palmonari, F.; Papi, A.; Park, I.H.; Pauluzzi, M.; Pauss, F.; Perrin, E.; Pesci, A.; Pevsner, A.; Pimenta, M.; Plyaskin, V.; Pojidaev, V.; Postolache, V.; Produit, N.; Rancoita, P.G.; Rapin, D.; Raupach, F.; Ren, D.; Ren, Z.; Ribordy, M.; Richeux, J.P.; Riihonen, E.; Ritakari, J.; Roeser, U.; Roissin, C.; Sagdeev, R.; Sartorelli, G.; Schultz von Dratzig, A.; Schwering, G.; Scolieri, G.; Seo, E.S.; Shoutko, V.; Shoumilov, E.; Siedling, R.; Son, D.; Song, T.; Steuer, M.; Sun, G.S.; Suter, H.; Tang, X.W.; Ting, S.C.C.Samuel C.C.; Ting, S.M.; Tornikoski, M.; Torsti, J.; Tr umper, J.; Ulbricht, J.; Urpo, S.; Usoskin, I.; Valtonen, E.; Vandenhirtz, J.; Velcea, F.; Velikhov, E.; Verlaat, B.; Vetlitsky, I.; Vezzu, F.; Vialle, J.P.; Viertel, G.; Vite, D.; Gunten, H. Von; Wicki, S.W.S. Waldmeier; Wallraff, W.; Wang, B.C.; Wang, J.Z.; Wang, Y.H.; Wiik, K.; Williams, C.; Wu, S.X.; Xia, P.C.; Yan, J.L.; Yan, L.G.; Yang, C.G.; Yang, M.; Ye, S.W.; Yeh, P.; Xu, Z.Z.; Zhang, H.Y.; Zhang, Z.P.; Zhao, D.X.; Zhu, G.Y.; Zhu, W.Z.; Zhuang, H.L.; Zichichi, A.; Zimmermann, B.

    2002-01-01

    The Alpha Magnetic Spectrometer (AMS) is a large acceptance (0.65 sr m 2 ) detector designed to operate in the International Space Station (ISS) for three years. The purposes of the experiment are to search for cosmic antimatter and dark matter and to study the composition and energy spectrum of the primary cosmic rays. A 'scaled-down' version has been flown on the Space Shuttle Discovery for 10 days in June 1998. The complete AMS is programmed for installation on the ISS in October 2003 for an operational period of 3 yr. This contribution reports on the experimental configuration that will be installed on the ISS

  8. Ion Mobility Spectrometer Field Test

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Nicholas [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; McLain, Derek [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Steeb, Jennifer [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division

    2017-12-20

    The Morpho Saffran Itemizer 4DX Ion Mobility Spectrometer previously used to detect uranium signatures in FY16 was used at the former New Brunswick Facility, a past uranium facility located on site at Argonne National Laboratory. This facility was chosen in an attempt to detect safeguards relevant signatures and has a history of processing uranium at various enrichments, chemical forms, and purities; various chemicals such as nitric acid, uranium fluorides, phosphates and metals are present at various levels. Several laboratories were sampled for signatures of nuclear activities around the laboratory. All of the surfaces that were surveyed were below background levels of the radioanalytical instrumentation and determined to be radiologically clean.

  9. Policy Innovation in Innovation Policy

    DEFF Research Database (Denmark)

    Borras, Susana

    as with national and sub-national governments in Europe, all of them introducing interesting novelties in their innovation policy. These changes refer to different aspects of policy, mainly the content of policy initiatives towards science, technology and innovation; the instruments governments are using...... to achieve their goals; and the actors in the policy system that are being mobilised in pursuing these goals. This paper deals with these policy changes, paying special attention to the novelties introduced since the early 1990s in Europe. The perspective of this paper deals mainly on the changes introduced...... at the EU level, and mentions similar trends taking place at national and sub-national levels. The questions that guide the contents here are essentially three, namely, what are the main traits of innovation policies in Europe since the 1990s and how have the EU and different national governments approached...

  10. Innovative Pedagogy

    DEFF Research Database (Denmark)

    The main purpose of this book is to take a closer look at how students and teachers in educational institutions apply the innovative, the playful and the emotional and creative dimensions of learning. With this contribution, the authors aim at reaching an international audience of educators at se...

  11. Financing Innovation

    International Development Research Centre (IDRC) Digital Library (Canada)

    Finance, real estate and business services are expanding their share with regard to government services. South Africa's ...... Although limited in amplitude, venture capital (VC) initiatives have existed since the 1980s, supported by the Brazilian Innovation Agency (FINEP) and BNDES (Melo 1988 and 1994). The question ...

  12. Balanced Innovation Management

    National Research Council Canada - National Science Library

    King, David R

    2007-01-01

    The Department of Defense has demonstrated success in managing innovation. The military's approach to innovation management extends beyond traditional distinctions between internal and external innovation modes...

  13. Ion cyclotron resonance spectrometer with fourier transformation

    International Nuclear Information System (INIS)

    Pikver, R.; Suurmaa, Eh.; Syugis, A.; Tammik, A.; Lippmaa, Eh.

    1983-01-01

    The ion cyclotron resonance spectrometer with Fourier transformation intended for investigating mass specta and chemical reaction kinetics in the gaseous phase is described. The mass-spectrum of CO and N 2 positive ions is shown. The spectrometer consists of an electromagnet with power supply, a vacuum system, a cell with electronic equipment and a minicomputer. In the vacuum system (5x10 -9 Torr) there is a cubic measuring cell heated up to 400 deg C. The spectrometer mass resolution is of the 10 5 order. The spectrometer is able to operate as a high-resolution analytical mass-spectrometer of positive and negative ions. The experience of the spectrometer operation confirms its effectiveness for investigating ion-molecular reactions, in particular, proton transfer reactions

  14. Fluorescence color diversity of great barrier reef corals

    Directory of Open Access Journals (Sweden)

    Grigory Lapshin

    2015-07-01

    Full Text Available A group of variously colored proteins belonging to the green fluorescent protein (GFP family are responsible for coloring coral tissues. Corals of the Great Barrier Reef were studied with the custom-built fiber laser fluorescence spectrometers. Spectral analysis showed that most of the examined corals contained multiple fluorescent peaks ranging from 470 to 620 nm. This observation was attributed to the presence of multiple genes of GFP-like proteins in a single coral, as well as by the photo-induced post-translational modifications of certain GFP-like proteins. We isolated a novel photo-convertible fluorescent protein (FP from one of the tested corals. We propose that two processes may explain the observed diversity of the fluorescent spectra in corals: (1 dark post-translational modification (maturation, and (2 color photo-conversion of certain maturated proteins in response to sunlight.

  15. Digital Spectrometers for Interplanetary Science Missions

    Science.gov (United States)

    Jarnot, Robert F.; Padmanabhan, Sharmila; Raffanti, Richard; Richards, Brian; Stek, Paul; Werthimer, Dan; Nikolic, Borivoje

    2010-01-01

    A fully digital polyphase spectrometer recently developed by the University of California Berkeley Wireless Research Center in conjunction with the Jet Propulsion Laboratory provides a low mass, power, and cost implementation of a spectrum channelizer for submillimeter spectrometers for future missions to the Inner and Outer Solar System. The digital polyphase filter bank spectrometer (PFB) offers broad bandwidth with high spectral resolution, minimal channel-to-channel overlap, and high out-of-band rejection.

  16. The construction of the SPEG spectrometer

    International Nuclear Information System (INIS)

    Gastebois, J.

    1979-01-01

    About two years ago, two distinct types of magnetic spectrometer were proposed. Since then for essentially financial reasons, only one type has been retained by the Scientific Council: the SPEG ('Energy loss spectrometer for GANIL'). This spectrometer is described in a technical document of April 1978. An overall view of the equipment is given here together with a survey of the means necessary for its realization [fr

  17. A computer based Moessbauer spectrometer system

    International Nuclear Information System (INIS)

    Jin Ge; Li Yuzhi; Yin Zejie; Yao Chunbo; Li Tie; Tan Yexian; Wang Jian

    1999-01-01

    A computer based Moessbauer spectrometer system with a single chip processor for online control and data acquisition is developed. The spectrometer is designed as a single-width NIM module and can be performed directly in NIM crate. Because the structure of the spectrometer is designed to be quite flexible, the system is easy to be configured with other kinds of Moessbauer driver, and can be used in other data acquisition systems

  18. Innovation Teams : Before Innovation Work is Begun

    OpenAIRE

    Johnsson, Mikael

    2014-01-01

    This paper focuses on innovation teams before innovation work is begun. The reason is that innovation teams are considered to be successful doing such work. However, prior studies show problems in innovation-related-knowledge, - knowledge gaps, -information and -awareness why this research aims to understand these aspects and how they relate to newly formed innovation team as they need to handle these aspects. Two case studies conducted during 1,5 years show that a newly formed innovation tea...

  19. Rethinking Open Innovation Beyond the Innovation Funnel

    OpenAIRE

    Wim Vanhaverbeke

    2013-01-01

    In his article, I first argue that open innovation can be applied in situations where companies do not themselves develop new products or services. As a consequence, open innovation becomes relevant for a much larger group of organizations than previously considered. Second, I argue that open-innovation scholars have insufficiently differentiated open-innovation initiatives in terms of their impact on companies’ growth: some open-innovation initiatives lead to incremental innovations in an ex...

  20. Innovation Enablers for Innovation Teams - A Review

    OpenAIRE

    Johnsson, Mikael

    2017-01-01

    This review consolidates research on innovation enablers for innovation teams, defined within this research as factors that enable a crossfunctional team within an organization to conduct innovation work, to provide a deeper understanding of what factors enable innovation teams to conduct innovation work, which means that this research involves three areas to provide a holistic picture: the organizational context, the team itself, and the individuals within the innovation team. A systematic d...

  1. Cryogenic Scan Mechanism for Fourier Transform Spectrometer

    Science.gov (United States)

    Brasunas, John C.; Francis, John L.

    2011-01-01

    A compact and lightweight mechanism has been developed to accurately move a Fourier transform spectrometer (FTS) scan mirror (a cube corner) in a near-linear fashion with near constant speed at cryogenic temperatures. This innovation includes a slide mechanism to restrict motion to one dimension, an actuator to drive the motion, and a linear velocity transducer (LVT) to measure the speed. The cube corner mirror is double-passed in one arm of the FTS; double-passing is required to compensate for optical beam shear resulting from tilting of the moving cube corner. The slide, actuator, and LVT are off-the-shelf components that are capable of cryogenic vacuum operation. The actuator drives the slide for the required travel of 2.5 cm. The LVT measures translation speed. A proportional feedback loop compares the LVT voltage with the set voltage (speed) to derive an error signal to drive the actuator and achieve near constant speed. When the end of the scan is reached, a personal computer reverses the set voltage. The actuator and LVT have no moving parts in contact, and have magnetic properties consistent with cryogenic operation. The unlubricated slide restricts motion to linear travel, using crossed roller bearings consistent with 100-million- stroke operation. The mechanism tilts several arc seconds during transport of the FTS mirror, which would compromise optical fringe efficiency when using a flat mirror. Consequently, a cube corner mirror is used, which converts a tilt into a shear. The sheared beam strikes (at normal incidence) a flat mirror at the end of the FTS arm with the moving mechanism, thereby returning upon itself and compensating for the shear

  2. Fluorogen-based reporters for fluorescence imaging: a review

    Science.gov (United States)

    Jullien, Ludovic; Gautier, Arnaud

    2015-12-01

    Fluorescence bioimaging has recently jumped into a new area of spatiotemporal resolution and sensitivity thanks to synergistic advances in both optical physics and probe/biosensor design. This review focuses on the recent development of genetically encodable fluorescent reporters that bind endogenously present or exogenously applied fluorogenic chromophores (so-called fluorogens) and activate their fluorescence. We highlight the innovative engineering and design that gave rise to these new natural and synthetic fluorescent reporters, and describe some of the emerging applications in imaging and biosensing.

  3. Innovation Assessment

    DEFF Research Database (Denmark)

    Hasselbalch, Jacob

    2017-01-01

    Current regulatory approaches are ill-equipped to address the challenges of governing through periods of disruptive technological change. This article hones in on the use of assessment regimes at the level of the European Union, particularly in the work of the Commission, to argue for a missing...... middle between technology assessment and impact assessment. Technology assessment focuses on the upstream governance of science and technology, while impact assessment focuses on the downstream governance of the impacts of specific policy options. What is missing is a form of midstream governance, which...... I label innovation assessment, to steer polities through periods of disruptive technological change, during which innovations have taken concrete forms and are beginning to diffuse, but still exhibit much scope for rapid, unexpected change and alternative trajectories of development. By juxtaposing...

  4. Innovations in urban agriculture

    NARCIS (Netherlands)

    Schans, van der J.W.; Renting, Henk; Veenhuizen, Van René

    2014-01-01

    This issuehighlights innovations in urban agriculture. Innovation and the various forms of innovations are of particular importance because urban agriculture is adapted to specific urban challenges and opportunities. Innovation is taking place continuously, exploring the multiple fundions of urban

  5. Depth resolved hyperspectral imaging spectrometer based on structured light illumination and Fourier transform interferometry

    Science.gov (United States)

    Choi, Heejin; Wadduwage, Dushan; Matsudaira, Paul T.; So, Peter T.C.

    2014-01-01

    A depth resolved hyperspectral imaging spectrometer can provide depth resolved imaging both in the spatial and the spectral domain. Images acquired through a standard imaging Fourier transform spectrometer do not have the depth-resolution. By post processing the spectral cubes (x, y, λ) obtained through a Sagnac interferometer under uniform illumination and structured illumination, spectrally resolved images with depth resolution can be recovered using structured light illumination algorithms such as the HiLo method. The proposed scheme is validated with in vitro specimens including fluorescent solution and fluorescent beads with known spectra. The system is further demonstrated in quantifying spectra from 3D resolved features in biological specimens. The system has demonstrated depth resolution of 1.8 μm and spectral resolution of 7 nm respectively. PMID:25360367

  6. The myths of innovation

    National Research Council Canada - National Science Library

    Berkun, Scott

    2007-01-01

    ... . . . . . . . . . . . . . . . . . . . . . . 1 Chapter 2 We understand the history of innovation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Chapter 3 There is a method for innovation...

  7. Time-of-flight spectrometers

    International Nuclear Information System (INIS)

    Carrico, J.P.

    1976-01-01

    The flight time of an ion in an inhomogeneous, oscillatory electric field (IOFE) is an m/e-dependent property of this field and is independent of the initial position and velocity. The d.c. component of the equation of motion for an ion in the IOFE describes a harmonic oscillation of constant period. When ions oscillate for many periods with one species overtaking another the motion may no longer be truly periodic although the resulting period or 'quasi-period' still remains independent of the initial conditions. This period or 'quasi-period' is used in the time-of-flight mass spectrometer described. The principle of operation is also described and both analytical and experimental results are reported. (B.D.)

  8. The BNL multiparticle spectrometer software

    International Nuclear Information System (INIS)

    Saulys, A.C.

    1985-01-01

    This paper discusses some solutions to problems common to the design, management and maintenance of a large high energy physics spectrometer software system. The experience of dealing with a large, complex program and the necessity of having the programm controlled by various people at different levels of computer experience has led us to design a program control structure of mnemonic and self-explanatory nature. The use of this control language in both ''on-line'' and ''off-line'' operation of the program will be discussed. The solution of structuring a large program for modularity so that substantial changes to the program can be made easily for a wide variety of high energy physics experiments is discussed. Specialized tools for this type of large program management are also discussed. (orig.)

  9. Tomato seeds maturity detection system based on chlorophyll fluorescence

    Science.gov (United States)

    Li, Cuiling; Wang, Xiu; Meng, Zhijun

    2016-10-01

    Chlorophyll fluorescence intensity can be used as seed maturity and quality evaluation indicator. Chlorophyll fluorescence intensity of seed coats is tested to judge the level of chlorophyll content in seeds, and further to judge the maturity and quality of seeds. This research developed a detection system of tomato seeds maturity based on chlorophyll fluorescence spectrum technology, the system included an excitation light source unit, a fluorescent signal acquisition unit and a data processing unit. The excitation light source unit consisted of two high power LEDs, two radiators and two constant current power supplies, and it was designed to excite chlorophyll fluorescence of tomato seeds. The fluorescent signal acquisition unit was made up of a fluorescence spectrometer, an optical fiber, an optical fiber scaffolds and a narrowband filter. The data processing unit mainly included a computer. Tomato fruits of green ripe stage, discoloration stage, firm ripe stage and full ripe stage were harvested, and their seeds were collected directly. In this research, the developed tomato seeds maturity testing system was used to collect fluorescence spectrums of tomato seeds of different maturities. Principal component analysis (PCA) method was utilized to reduce the dimension of spectral data and extract principal components, and PCA was combined with linear discriminant analysis (LDA) to establish discriminant model of tomato seeds maturity, the discriminant accuracy was greater than 90%. Research results show that using chlorophyll fluorescence spectrum technology is feasible for seeds maturity detection, and the developed tomato seeds maturity testing system has high detection accuracy.

  10. Intrinsic fluorescence biomarkers in cells treated with chemopreventive drugs

    Science.gov (United States)

    Kirkpatrick, Nathaniel D.; Brands, William R.; Zou, Changping; Brewer, Molly A.; Utzinger, Urs

    2005-03-01

    Non-invasive monitoring of cellular metabolism offers promising insights into areas ranging from biomarkers for drug activity to cancer diagnosis. Fluorescence spectroscopy can be utilized in order to exploit endogenous fluorophores, typically metabolic co-factors nicotinamide adenine dinucleotide (NADH) and flavin adenine dinucleotide (FAD), and estimate the redox status of the sample. Fluorescence spectroscopy was applied to follow metabolic changes in epithelial ovarian cells as well as bladder epithelial cancer cells during treatment with a chemopreventive drug that initiates cellular quiescence. Fluorescence signals consistent with NADH, FAD, and tryptophan were measured to monitor cellular activity, redox status, and protein content. Cells were treated with varying concentrations of N-4-(hydroxyphenyl) retinamide (4-HPR) and measured in a stable environment with a sensitive fluorescence spectrometer. A subset of measurements was completed on a low concentration of cells to demonstrate feasibility for medical application such as in bladder or ovary washes. Results suggest that all of the cells responded with similar dose dependence but started at different estimated redox ratio baseline levels correlating with cell cycle, growth inhibition, and apoptosis assays. NADH and tryptophan related fluorescence changed significantly while FAD related fluorescence remained unaltered. Fluorescence data collected from approximately 1000 - 2000 cells, comparable to a bladder or ovary wash, was measurable and useful for future experiments. This study suggests that future intrinsic biomarker measurements may need to be most sensitive to changes in NADH and tryptophan related fluorescence while using FAD related fluorescence to help estimate the baseline redox ratio and predict response to chemopreventive agents.

  11. Time-resolved laser-induced fluorescence system

    Science.gov (United States)

    Bautista, F. J.; De la Rosa, J.; Gallegos, F. J.

    2006-02-01

    Fluorescence methods are being used increasingly in the measurement of species concentrations in gases, liquids and solids. Laser induced fluorescence is spontaneous emission from atoms or molecules that have been excited by laser radiation. Here we present a time resolved fluorescence instrument that consists of a 5 μJ Nitrogen laser (337.1 nm), a sample holder, a quartz optical fiber, a spectrometer, a PMT and a PC that allows the measurement of visible fluorescence spectra (350-750 nm). Time response of the system is approximately 5 ns. The instrument has been used in the measurement of colored bond paper, antifreeze, diesel, cochineal pigment and malignant tissues. The data acquisition was achieved through computer control of a digital oscilloscope (using General Purpose Interface Bus GPIB) and the spectrometer via serial (RS232). The instrument software provides a graphic interface that lets make some data acquisition tasks like finding fluorescence spectra, and fluorescence lifetimes. The software was developed using the Lab-View 6i graphic programming package and can be easily managed in order to add more functions to it.

  12. Laboratory EXAFS Spectrometer, Principles and Applications

    NARCIS (Netherlands)

    Koningsberger, D.C.; Kampers, F.W.H.; Duivenvoorden, F.B.M.; Zon, J.B.A.D. van; Brinkgreve, P.; Viegers, M.P.A.

    1985-01-01

    In order to be independent of poor availability of synchrotron beamtime a laboratory EXAFS spectrometer has been developed. The X-ray source is a rotating anode generator (max. voltage 60 kV, max. current 300 mA). Monochromatisation and focusing is done with a linear spectrometer, based upon the

  13. The high momentum spectrometer drift chambers

    Science.gov (United States)

    Abbott, D.; Baker, O. K.; Beaufait, J.; Bennett, C.; Bryant, E.; Carlini, R.; Kross, B.; McCauley, A.; Naing, W.; Shin, T.; Vulcan, W.

    1992-12-01

    The High Momentum Spectrometer in Hall C will use planar drift chambers for charged particle track reconstruction. The chambers are constructed using well understood technology and a conventional gas mixture. Two (plus one spare) drift chambers will be constructed for this spectrometers. Each chamber will contain 6 planes of readout channels. This paper describes the chamber design and gas handling system used.

  14. The MIRI Medium Resolution Spectrometer calibration pipeline

    NARCIS (Netherlands)

    Labiano, A.; Azzollini, R.; Bailey, J.; Beard, S.; Dicken, D.; García-Marín, M.; Geers, V.; Glasse, A.; Glauser, A.; Gordon, K.; Justtanont, K.; Klaassen, P.; Lahuis, F.; Law, D.; Morrison, J.; Müller, M.; Rieke, G.; Vandenbussche, B.; Wright, G.

    2016-01-01

    The Mid-Infrared Instrument (MIRI) Medium Resolution Spectrometer (MRS) is the only mid-IR Integral Field Spectrometer on board James Webb Space Telescope. The complexity of the MRS requires a very specialized pipeline, with some specific steps not present in other pipelines of JWST instruments,

  15. A Mass Spectrometer Simulator in Your Computer

    Science.gov (United States)

    Gagnon, Michel

    2012-01-01

    Introduced to study components of ionized gas, the mass spectrometer has evolved into a highly accurate device now used in many undergraduate and research laboratories. Unfortunately, despite their importance in the formation of future scientists, mass spectrometers remain beyond the financial reach of many high schools and colleges. As a result,…

  16. Open innovations, innovation communities and firm's innovative activities

    Directory of Open Access Journals (Sweden)

    Getejanc Vesna

    2016-01-01

    Full Text Available The open innovation paradigm emphasizes the fact that firms can improve their performance by opening their business models and reduce their R&D costs by effective incorporation of external knowledge. In other words, companies are able to capture value through knowledge that exists outside the boundaries of their organization. The shift from closed to open model of innovation has imposed the necessity to adopt more open approach to innovation within traditional academic view of business strategy. The adoption of this innovative approach is emphasized even more, by the necessity for stronger connection and cooperation among the participants of the innovation process. Free will and collaboration are the main characteristics of open source software, which is recognized in literature as the role model of open innovation and is a rapidly growing method of technology development. Furthermore, innovative communities represent a great opportunity for improvement of the companies' innovation activities, since they have become an important source for identifying the needs and problems of the users. Their development has been fostered by information technologies and recent social changes in user behavior. Recognizing and better understanding the motivation of the members of the innovation communities that guide them to participate in the process of idea generation, can have significant influence on their incorporation within the innovation process. Equally important is to define the incentives that are suited for stimulating and fostering innovative user activities. Taking this topic in consideration, the purpose of this article is to address the following questions: In what way does the collaboration in open source software projects have positive effect on companies' innovation performance? What are the innovation communities and how can companies establish successful interaction with them? Why does the interaction with innovation communities lead to

  17. Modeling mini-orange electron spectrometers

    International Nuclear Information System (INIS)

    Canzian da Silva, Nelson; Dietzsch, Olacio

    1994-01-01

    A method for calculating the transmission of mini-orange electron spectrometers is presented. The method makes use of the analytical solution for the magnetic field of a plane magnet in the calculation of the spectrometer spatial field distribution by superimposing the fields of the several magnets that compose the system. Electron trajectories through the spectrometer are integrated numerically in a Monte Carlo calculation and the transmission of the spectrometer as a function of the electron energy is evaluated. A six-magnet mini-orange spectrometer was built and its transmission functions for several distances from source to detector were measured and compared to the calculations. The overall agreement is found to be good. The method is quite general and can be applied to the design of systems composed of plane magnets, predicting their performance before assembling them. ((orig.))

  18. Reviews in fluorescence 2010

    CERN Document Server

    Geddes, Chris D

    2011-01-01

    ""Reviews in Fluorescence 2010"", the seventh volume of the book serial from Springer, serves as a comprehensive collection of current trends and emerging hot topics in the field of fluorescence and closely related disciplines. It summarizes the year's progress in fluorescence and its applications, with authoritative analytical reviews specialized enough to be attractive to professional researchers, yet also appealing to the wider audience of scientists in related disciplines of fluorescence. ""Reviews in Fluorescence"" offers an essential reference material for any lab working in the fluoresc

  19. Innovative Therapeutics

    Directory of Open Access Journals (Sweden)

    Laura M.G. Meems, MD, PhD

    2016-12-01

    Full Text Available Natriuretic peptides (NPs are essential for the maintenance of volume homeostasis, and can be of myocardial, renal, and endothelial origin. Advances in peptide engineering have enabled the design of innovative designer NPs that go beyond native peptides in efficacy, specificity, and resistance to enzymatic degradation. Therefore, designer NPs provide an unparalleled opportunity for the treatment of cardiovascular disease. In this review, we report the conceptual framework of peptide engineering of the NPs that resulted in designer peptides for cardiovascular disease. We specifically provide an update on those currently in clinical trials for heart failure and hypertension.

  20. Innovative instrumentation

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    At this year's particle physics conference at Brighton, a parallel session was given over to instrumentation and detector development. While this work is vital to the health of research and its continued progress, its share of prime international conference time is limited. Instrumentation can be innovative three times — first when a new idea is outlined, secondly when it is shown to be feasible, and finally when it becomes productive in a real experiment, amassing useful data rather than operational experience. Hyams' examples showed that it can take a long time for a new idea to filter through these successive stages, if it ever makes it at all

  1. Lippmann waveguide spectrometer with enhanced throughput and bandwidth for space and commercial applications.

    Science.gov (United States)

    Madi, Mohammad; Ceyssens, Frederik; Shorubalko, Ivan; Herzig, Hans Peter; Guldimann, Benedikt; Giaccari, Philippe

    2018-02-05

    This article presents an innovative high spectral resolution waveguide spectrometer, from the concept to the prototype demonstration and the test results. The main goal is to build the smallest possible Fourier transform spectrometer (FTS) with state of the art technology. This waveguide FTS takes advantage of a customized pattern of nano-samplers fabricated on the surface of a planar waveguide that allows the increase of the measurement points necessary for increasing the spectral bandwidth of the FTS in a fully static way. The use of a planar waveguide on the other hand allows enhancing the throughput in a waveguide spectrometer compared to the conventional devices made of single-mode waveguides. A prototype is made in silicon oxynitride/silicon dioxide technology and characterized in the visible range. This waveguide spectrometer shows a nominal bandwidth of 256~nm at a central wavelength of 633~nm thanks to a custom pattern of nanodisks providing a μm sampling interval. The implementation of this innovative waveguide FTS for a real-case scenario is explored and further development of such device for the imaging FTS application is discussed.

  2. Raman spectroscopy using a spatial heterodyne spectrometer: proof of concept.

    Science.gov (United States)

    Gomer, Nathaniel R; Gordon, Christopher M; Lucey, Paul; Sharma, Shiv K; Carter, J Chance; Angel, S Michael

    2011-08-01

    The use of a spatial heterodyne interferometer-based spectrometer (SHS) for Raman spectroscopy is described. The motivation for this work is to develop a small, rugged, high-resolution ultraviolet (UV) Raman spectrometer that is compatible with pulsed laser sources and that is suitable for planetary space missions. UV Raman is a particular technical challenge for space applications because dispersive (grating) approaches require large spectrographs and very narrow slits to achieve the spectral resolution required to maximize the potential of Raman spectroscopy. The heterodyne approach of the SHS has only a weak coupling of resolution and throughput, so a high-resolution UV SHS can both be small and employ a wide slit to maximize throughput. The SHS measures all optical path differences in its interferogram simultaneously with a detector array, so the technique is compatible with gated detection using pulsed lasers, important to reject ambient background and mitigate fluorescence (already low in the UV) that might be encountered on a planetary surface where samples are uncontrolled. The SHS has no moving parts, and as the spectrum is heterodyned around the laser wavelength, it is particularly suitable for Raman measurements. In this preliminary report we demonstrate the ability to measure visible wavelength Raman spectra of liquid and solid materials using an SHS Raman spectrometer and a visible laser. Spectral resolution and bandpass are also discussed. Separation of anti-Stokes and Stokes Raman bands is demonstrated using two different approaches. Finally spectral bandpass doubling is demonstrated by forming an interference pattern in both directions on the ICCD detector followed by analysis using a two-dimensional Fourier transform.

  3. Apollo 15 X-ray fluorescence experiment

    Science.gov (United States)

    Adler, I.; Trombka, J.; Gerard, J.; Schmadebeck, R.; Lowman, P.; Blodgett, H.; Yin, L.; Eller, E.; Lamothe, R.; Gorenstein, P.

    1971-01-01

    The X-ray fluorescence spectrometer, carried in the SIM bay of the command service module was employed principally for compositional mapping of the lunar surface while in lunar orbit, and secondarily, for X-ray astronomical observations during the trans-earth coast. The lunar surface measurements involved observations of the intensity and characteristics energy distribution of the secondary or fluorescent X-rays produced by the interaction of solar X-rays with the lunar surface. The astronomical observations consisted of relatively long periods of measurements of X-rays from pre-selected galactic sources such as Cyg-X-1 and Sco X-1 as well as from the galactic poles.

  4. Approaching Service Innovation Patterns

    OpenAIRE

    NAGY Andrea

    2013-01-01

    The present paper aims at analyzing the types of innovation in the field of services. First, the concept of innovation is defined and second, field literature is reviewed from the perspective of service innovation. The main types of innovation are identified based on several attempts at defining innovation, the most notable being Schumpeter’s. Thus, it is possible to approach concepts such as product and process innovation, incremental and radical innovation. Another aim has been to regard se...

  5. Fluorescent optical position sensor

    Science.gov (United States)

    Weiss, Jonathan D.

    2005-11-15

    A fluorescent optical position sensor and method of operation. A small excitation source side-pumps a localized region of fluorescence at an unknown position along a fluorescent waveguide. As the fluorescent light travels down the waveguide, the intensity of fluorescent light decreases due to absorption. By measuring with one (or two) photodetectors the attenuated intensity of fluorescent light emitted from one (or both) ends of the waveguide, the position of the excitation source relative to the waveguide can be determined by comparing the measured light intensity to a calibrated response curve or mathematical model. Alternatively, excitation light can be pumped into an end of the waveguide, which generates an exponentially-decaying continuous source of fluorescent light along the length of the waveguide. The position of a photodetector oriented to view the side of the waveguide can be uniquely determined by measuring the intensity of the fluorescent light emitted radially at that location.

  6. Reviews in fluorescence 2008

    CERN Document Server

    Geddes, Chris D

    2010-01-01

    This volume serves as a comprehensive collection of current trends and emerging hot topics in the field of fluorescence spectroscopy. It summarizes the year's progress in fluorescence and its applications as well as includes authoritative analytical reviews.

  7. Fluorescence correlation spectroscopy

    NARCIS (Netherlands)

    Hink, M.A.; Verveer, P.J.

    2015-01-01

    Fluorescence fluctuation spectroscopy techniques allow the quantification of fluorescent molecules present at the nanomolar concentration level. After a brief introduction to the technique, this chapter presents a protocol including background information in order to measure and quantify the

  8. [The coding correction of slit diffraction in Hadamard transform spectrometer].

    Science.gov (United States)

    Li, Bo; Wang, Shu-Rong; Huang, Yu; Wang, Jun-Bo

    2013-08-01

    According to the principles of Hadamard transform spectrometer and the slit diffraction characteristics, the influence of spectrometer entrance slit diffraction of Hadamard transform spectrometer on the measurement result was analyzed, for the diffraction case, the Hadamard transform spectrometer instrument structure matrix was studied, and the Hadamard transform spectrometer encoding/decoding method was established. The analysis of incident spectral verified the correctness of the coding/ decoding. This method is very important for the high precision measurement of Hadamard transform spectrometer.

  9. Raman spectrometer with microprobe capability

    Science.gov (United States)

    Boyd, J. T.; Jackson, H. E.

    1986-01-01

    This report describes the results of this equipment grant funded as a part of the Department of Defense (DOD) University Research Instrumentation Program. This grant funded the purchase of a Raman spectrometer with microprobe capability having resolution of 1.0 micron. This report describes the equipment selecting decision, the configuration of the instrument selected, and some experimental results. The experimental results include Raman spectra used in characterization of laser recrystallized silicon and ion implanted regions in semi-insulating GaAs. The Raman microprobe can be used to characterize the effects of substrate temperature, beam power density and shape, beam scan speed and direction, deposition rate, substrate seeding, and polysilicon encapsulation schemes both near and away from grain boundaries. The frequency shift and the peak width of the Raman scattering from the triply degenerate zone center phonon in Si allow determination of the strain in the grains of laser recrystallized polysilicon. Reducing these strains will allow us to achieve large single grains of device quality.

  10. An Infrared Drill Borehole Spectrometer for Mars

    Science.gov (United States)

    Smythe, W.; Foote, M.; Johnson, E.; Daly, J.; Loges, P.; Puscasu, I.; Gorevan, S.; Chu, P.; Granahan, J.

    2005-08-01

    The best clues to Mars past may be hidden below the surface of Mars. Long exposure to the sun, high winds and dust storms, large diurnal temperature excursions, and eons of space weathering combine to render a greatly modified surface, in many instances remarkable for its appearance of uniform composition. Drilling can provide access to the layers in the caps, to the permafrost and possibly, to pristine crustal material. The drilling process is complex with high demand on support resources. It is vital to make the drilling process as efficient as possible. A most promising approach is to instrument the drill string itself, thereby avoiding the complexity of sample handling, speeding and simplifying drill operations, and allowing examination of freshly exposed surfaces within the borehole. A solid-state IR spectrometer is being integrated with a blackbody source into a package to fit within an existing Mars drill design. The borehole IR spectrometer is used to monitor facies encountered throughout the drilling process. The spectrometer/IR combination is used in reflectance spectrometer mode to monitor H2O and CO2 content, as well as iron and carbonate mineralogies. Integration required adapting the existing spectrometer to fit within the drill -- including attaching the detectors directly to the spectrometer waveguide, developing the techniques required to seal the micro-thermopile detectors to the waveguide, implementing miniaturized digital conversion electronics, combining the spectrometer with the IR source and coupling them to a suitable window, implementing a suitable sealed package to fit within the drill, integrating and testing the package on a drill, and establishing the proper gain for both stimulus and spectrometer to permit reasonable range of Mars soil analogs. Tests have shown that both sapphire and diamond windows perform well in the drilling environment. Testing of the integrated spectrometer and drill will be completed in the coming year.

  11. Miniature and micro spectrometers market: who is going to catch the value?

    Science.gov (United States)

    Bouyé, Clémentine; d'Humières, Benoît

    2017-02-01

    The market of miniature and micro spectrometers is evolving fast. The technology is getting ever smaller and cheaper while keeping high performances. The market is attracting new players: spin-offs from major research institutes, large companies outside the classic spectroscopy market, software providers with innovative analytical solutions, … The goal of this involvement is to bring spectroscopy closer to the end-users and provide spectrometers able to operate on-field or in-line. The high potential of compact spectrometers is recognized for a wide variety of applications: chemistry, pharmaceutics, agro-food, agriculture, forensics, healthcare, consumer applications, … But its emergence as a large volume market faces a major bottleneck. Each application implies specific processes and analyses and specific parameters to control, i.e. a specific interpretation of the raw spectra in order to provide information usable by nonphotonic experts. Who is going to pay for that adaptation effort? Are there ways for reducing the adaptation costs, by means of selflearning algorithms and/or flexible and easily adaptable sensors? In other words, who is going to catch the value? In this article, we will investigate the potential of each major industrial application market and provide market data. We will also wonder, what are the strengths and weaknesses of the different players - spectrometer manufacturers, algorithms developers, full-systems providers, … - to catch the value of the compact spectrometer market.

  12. Advanced, Compact, Ultraviolet Imaging Spectrometer for Planetary Systems

    Data.gov (United States)

    National Aeronautics and Space Administration — The Advanced, Compact, Ultraviolet Imaging Spectrometer for Planetary Systems will advance the capabilities of ultraviolet imaging spectrometers by improving the...

  13. [Development of Micro-Spectrometer with a Function of Timely Temperature Compensation].

    Science.gov (United States)

    Bao, Jian-guang; Liu, Zheng-kun; Chen, Huo-yao; Lin, Ji-ping; Fu, Shao-jun

    2015-05-01

    Temperature drift will be brought to Micro-Spectrometer used for demodulating the Varied Line-Space(VLS) grating position sensor on aircraft due to high-low temperature shock. We successfully made a Micro-Spectrometer, for the VLS grating position sensor on aircraft, which still have stable output under temperature shock enviro nment. In order to present a real time temperature compensation scheme, the effects temperature change has on Micro-Spectrometer are analyzed and the traditional cross Czerny-Turner (C-T)optical structure is optimized. Both optical structures are analyzed by optics design software ZEMAX and proved that comparedwithtraditional cross C-T optical structure, the newone can accomplish not only smaller spectrum drift but also spectrum drift with better linearity. Based on the new optical structure. The scheme of using reference wavelength to accomplish real time temperature compensation was proposed and a Micro-fiber Spectrometer was successfully manufactured, whith is with Volume of 80 mm X 70 mmX 70 mm, integration time of 8 ~1 000 ms and FullWidthHalfMaximum(FWHM) of 2 nm. Experiments show that the new spectrometer meets the design requirement. Under high temperature in the range of nearly 60 °C, the standard error of wavelength of this new spectrometer is smaller than 0. 1 nm, and the maximum error of wavelength is 0. 14 nm, which is much smaller than required 0. 3 nm. Innovations of this paper are the schemeof real time temperature compensation, the new cross C-T optical structure and a Micro-fiber Spectrometer based on it.

  14. Measuring and interpreting X-ray fluorescence from planetary surfaces.

    Science.gov (United States)

    Owens, Alan; Beckhoff, Burkhard; Fraser, George; Kolbe, Michael; Krumrey, Michael; Mantero, Alfonso; Mantler, Michael; Peacock, Anthony; Pia, Maria-Grazia; Pullan, Derek; Schneider, Uwe G; Ulm, Gerhard

    2008-11-15

    As part of a comprehensive study of X-ray emission from planetary surfaces and in particular the planet Mercury, we have measured fluorescent radiation from a number of planetary analog rock samples using monochromatized synchrotron radiation provided by the BESSY II electron storage ring. The experiments were carried out using a purpose built X-ray fluorescence (XRF) spectrometer chamber developed by the Physikalisch-Technische Bundesanstalt, Germany's national metrology institute. The XRF instrumentation is absolutely calibrated and allows for reference-free quantitation of rock sample composition, taking into account secondary photon- and electron-induced enhancement effects. The fluorescence data, in turn, have been used to validate a planetary fluorescence simulation tool based on the GEANT4 transport code. This simulation can be used as a mission analysis tool to predict the time-dependent orbital XRF spectral distributions from planetary surfaces throughout the mapping phase.

  15. Innovators Intent

    DEFF Research Database (Denmark)

    Granados, Maria Luisa; Rai, Sudhanshu

    With this paper we want to explore further the innovators intent, where social enterprises use imaginative ways to take advantage of information technology to create, share and manage the knowledge pool of their small enterprise. We draw on several perspectives on how information processing needs...... of understanding on how IT can support the management of knowledge within the context of SEs dealing with different contextual settings influenced by: constant tensions between social and economic objectives, more focus on sustainability than competiveness, limited resources, and high levels of democratic...... are addressed, as well as the manner in which IT enables and facilitates sense-making. Studies exploring the role of IT in organisations abound, however our focus is not large organisations but small social enterprises (SEs) and how they use IT to further their business objectives. Hence there is still a lack...

  16. Funding innovation

    CERN Multimedia

    Marina Giampietro

    2012-01-01

    For the first time, six knowledge and technology transfer activities are set to benefit from a dedicated fund made available by the Knowledge Transfer group. This initiative cements CERN’s commitment to sharing its technological knowledge and expertise with society.   GEM detectors for flame detection and early earthquake prediction, radio-frequency absorbers for energy recovery, and exotic radioisotopes for medical applications are among the projects funded by the recently introduced KT Fund. “CERN’s scientific programme generates a considerable amount of intellectual property, a natural driver for innovation,” explains Giovanni Anelli, Head of the Knowledge Transfer Group. “Very often, though, financial support is needed to bring the newly-born technologies a step further and make them ready for transfer to other research institutes or to companies.” This is where the KT fund comes into play. It provides vital support in the early sta...

  17. Guided-wave high-performance spectrometers for the MEOS miniature earth observation satellite

    Science.gov (United States)

    Kruzelecky, Roman V.; Wong, Brian; Zou, Jing; Jamroz, Wes; Sloan, James; Cloutis, Edward

    2017-11-01

    The MEOS Miniature Earth Observing Satellite is a low-cost mission being developed for the Canadian Space Agency with international collaborations that will innovatively combine remote correlated atmospheric/land-cover measurements with the corresponding atmospheric and ecosystem modelling in near real-time to obtain simultaneous variations in lower tropospheric GHG mixing ratios and the resulting responses of the surface ecosystems. MEOS will provide lower tropospheric CO2, CH4, CO, N2O, H2O and aerosol mixing ratios over natural sources and sinks using two kinds of synergistic observations; a forward limb measurement and a follow-on nadir measurement over the same geographical tangent point. The measurements will be accomplished using separate limb and nadir suites of innovative miniature line-imaging spectrometers and will be spatially coordinated such that the same air mass is observed in both views within a few minutes. The limb data will consist of 16-pixel vertical spectral line imaging to provide 1-km vertical resolution, while the corresponding nadir measurements will view sixteen 5 by 10 km2 ground pixels with a 160-km East-West swath width. To facilitate the mission accommodation on a low-cost microsat with a net payload mass under 22 kg, groundbreaking miniature guided-wave spectrometers with advanced optical filtering and coding technologies will be employed based on MPBC's patented IOSPEC technologies. The data synergy requirements for each view will be innovatively met using two complementary miniature line-imaging spectrometers to provide broad-band measurements from 1200 to 2450 nm at about 1.2 nm/pixel bandwidth using a multislit binary-coded MEMS-IOSPEC and simultaneous high-resolution multiple microchannels at 0.03 nm FWHM using the revolutionary FP-IOSPEC Fabry-Perot guided-wave spectrometer concept. The guided-wave spectrometer integration provides an order of magnitude reduction in the mass and volume relative to traditional bulk

  18. Injection Seeded Laser for Formaldehyde Differential Fluorescence Lidar

    Directory of Open Access Journals (Sweden)

    Schwemmer G.

    2016-01-01

    Full Text Available We describe the design and development of an injection seeded Nd:YVO4 laser for use in a differential fluorescence lidar for measuring atmospheric formaldehyde profiles. A high repetition rate Q-switched laser is modified to accept injection seed input to spectrally narrow and tune the output. The third harmonic output is used to excite formaldehyde (HCHO fluorescence when tuned to a HCHO absorption line. Spectral confirmation is made with the use of a photoacoustic cell and grating spectrometer.

  19. Preliminary results of absolute wavelength calibration of imaging X-ray crystal spectrometer on EAST

    Energy Technology Data Exchange (ETDEWEB)

    Pan, Xiayun [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); University of Science and Technology of China, Hefei 230026 (China); Wang, Fudi [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Chen, Jun [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); University of Science and Technology of China, Hefei 230026 (China); Lyu, Bo, E-mail: blu@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Li, Yingying; Fu, Jia; Xu, Liqing [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Shi, Yuejiang [University of Science and Technology of China, Hefei 230026 (China); Department of Nuclear Engineering, Seoul National University, Seoul 151-742 (Korea, Republic of); Ye, Minyou [University of Science and Technology of China, Hefei 230026 (China); Wan, Baonian [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China)

    2015-10-15

    Highlights: • The absolute wavelength calibration method for X-ray crystal spectrometer using X-ray fluorescence of the appropriate materials was first tested on EAST, and the preliminary experimental results were obtained. • The experimental results were thoroughly discussed and suggestion for further improvements of the experimental arrangement was proposed. • Rotation calibration of X-ray crystal spectrometer on EAST using MHD frequency was presented when the absolute wavelength calibration method is unavailable currently. - Abstract: Imaging X-ray crystal spectrometers (XCS) are currently operating on several major tokamaks to provide profiles of ion temperature and rotation velocity. In order to acquire absolute rotation velocity, several indirect methods were pursued previously, however the direct and effective method is to use known X-ray lines for wavelength calibration. One way to produce standard spectral lines is X-ray fluorescence, which could be excited by X-rays from tokamak plasmas. As part of the upgrade of XCS system on EAST, wavelength calibration was studied using cadmium's L-shell lines, namely Lα{sub 1} line (3.9564 Å) and Lα{sub 2} line (3.9650 Å) as the reference wavelength. The Geant 4 code was used to optimize foil thickness to achieve a reasonable X-ray fluorescence intensity. The Cd foil was placed between the beryllium window and crystal and could be retracted to provide in situ wavelength calibration. The detailed arrangement and preliminary wavelength calibration results of imaging X-ray crystal spectrometer on EAST are presented, plus the calibration using MHD frequency.

  20. The VERDI fission fragment spectrometer

    International Nuclear Information System (INIS)

    Fregeau, M. O.; Brys, T.; Gamboni, T.; Geerts, W.; Oberstedt, S.; Oberstedt, A.; Borcea, R.

    2013-01-01

    The VERDI time-of-flight spectrometer is dedicated to measurements of fission product yields and of prompt neutron emission data. Pre-neutron fission-fragment masses will be determined by the double time-of-flight (TOF) technique. For this purpose an excellent time resolution is required. The time of flight of the fragments will be measured by electrostatic mirrors located near the target and the time signal coming from silicon detectors located at 50 cm on both sides of the target. This configuration, where the stop detector will provide us simultaneously with the kinetic energy of the fragment and timing information, significantly limits energy straggling in comparison to legacy experimental setup where a thin foil was usually used as a stop detector. In order to improve timing resolution, neutron transmutation doped silicon will be used. The high resistivity homogeneity of this material should significantly improve resolution in comparison to standard silicon detectors. Post-neutron fission fragment masses are obtained form the time-of-flight and the energy signal in the silicon detector. As an intermediary step a diamond detector will also be used as start detector located very close to the target. Previous tests have shown that poly-crystalline chemical vapour deposition (pCVD) diamonds provides a coincidence time resolution of 150 ps not allowing complete separation between very low-energy fission fragments, alpha particles and noise. New results from using artificial single-crystal diamonds (sCVD) show similar time resolution as from pCVD diamonds but also sufficiently good energy resolution. (authors)

  1. Progress of the BESS Superconducting Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Haino, S. E-mail: haino@icepps.s.u-tokyo.ac.jp; Abe, K.; Anraku, K.; Fuke, H.; Hams, T.; Ikeda, N.; Itasaki, A.; Izumi, K.; Kumazawa, T.; Lee, M.H.; Maeno, T.; Makida, Y.; Matsuda, S.; Matsui, N.; Matsumoto, H.; Matsumoto, K.; Mitchell, J.W.; Moiseev, A.A.; Nishimura, J.; Nozaki, M.; Omiya, H.; Orito, S.; Ormes, J.F.; Sanuki, T.; Sasaki, M.; Seo, E.S.; Shikaze, Y.; Streitmatter, R.E.; Suzuki, J.; Takasugi, Y.; Takeuchi, S.; Tanaka, K.; Taniguchi, T.; Tanizaki, K.; Yamagami, T.; Yamamoto, A.; Yamamoto, Y.; Yamato, K.; Yoshida, T.; Yoshimura, K

    2004-02-01

    Balloon-borne Experiment with a Superconducting Spectrometer (BESS) is a balloon-borne spectrometer to study elementary particle phenomena in the early Universe as well as the origin and the propagation of cosmic radiation. The instrument has a unique feature of a thin superconducting solenoid which enables a large acceptance with a cylindrical configuration. Nine balloon flights have been successfully carried out since 1993. In 2002, the detector was upgraded as the BESS-TeV spectrometer to extend primary cosmic-ray spectra up to 1 TeV. For further studies of low-energy antiprotons, a new spectrometer, BESS-Polar, with a ultra-thin superconducting solenoid is being developed for long duration balloon flights in Antarctica.

  2. Low Power FPGA Based Spectrometer Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to design a general purpose reconfigurable wide bandwidth spectrometer for use in NASA's passive microwave missions, deep space network and radio...

  3. TRISP: Three axes spin echo spectrometer

    Directory of Open Access Journals (Sweden)

    Thomas Keller

    2015-12-01

    Full Text Available TRISP, operated by the Max-Planck-Institute for Solid State Research, is a high-resolution neutron spectrometer combining the three axes and neutron resonance spin echo (NRSE techniques.

  4. RITA-type triple axis spectrometers

    International Nuclear Information System (INIS)

    Roennow, H.M.

    2001-01-01

    The RITA spectrometer at Risoe National Laboratory was the first to incorporate a complete re-thinking of the neutron-path from source, through detector to analysis. Since then, other RITA-type spectrometers such as SPINS at NIST, RITA-II at PSI have been built, and several new spectrometers around the world are adapting the same philosophy. The main novelty of RITA was the introduction of a single back-end tank featuring both an analyser block with multiple individually turnable analyser blades and a 2D position sensitive detector. Several new triple-axis spectrometers are presently being built at existing and future sources, and almost all of them have learnt from the experience with RITA. (R.P.)

  5. View of the Axial Field Spectrometer

    CERN Multimedia

    1980-01-01

    The Axial Field Spectrometer, with the vertical uranium/scintillator calorimeter and the central drift chamber retracted for service. One coil of the Open Axial Field Magnet is just visible to the right.

  6. Computer control in a compton scattering spectrometer

    International Nuclear Information System (INIS)

    Cui Ningzhuo; Chen Tao; Gong Zhufang; Yang Baozhong; Mo Haiding; Hua Wei; Bian Zuhe

    1995-01-01

    The authors introduced the hardware and software of computer autocontrol of calibration and data acquisition in a Compton Scattering spectrometer which consists of a HPGe detector, Amplifiers and a MCA

  7. Electrostatic Spectrometer for Mars Rover Wheel

    Data.gov (United States)

    National Aeronautics and Space Administration — Develop a simple electrostatic spectrometer that can be mounted on the wheels of a Mars rover to continuously and unobtrusively determine the mineral composition and...

  8. Low Power FPGA Based Spectrometer, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to design a general purpose reconfigurable wide bandwidth spectrometer for use in NASA's passive microwave missions, deep space network and radio...

  9. MGS SAMPLER THERMAL EMISSION SPECTROMETER GLOBAL TEMPERATURE

    Data.gov (United States)

    National Aeronautics and Space Administration — This archive contains Thermal Emission Spectrometer (TES) 25-micron global surface temperature data, collected during the ANS portion of the Mars Global Surveyor...

  10. Innovation in Your Community

    Science.gov (United States)

    EPA has many innovation programs that can help the public bring innovative solutions to their local areas by reducing waste, engaging students to contribute innovative ideas, and helping businesses implement sustainable practices.

  11. Organizing Systemic Innovation

    NARCIS (Netherlands)

    F.P.H. Jaspers (Ferdinand)

    2009-01-01

    textabstractSystemic innovation refers to product development activities that involve the change of multiple interdependent components. Unlike autonomous innovation, which refers to components that change independently, systemic innovation is for many firms the norm rather than the exception. This

  12. Design and construction of a NIR spectrometer

    CERN Document Server

    Barcala-Riveira, J M; Fernandez-Marron, J L; Molero-Menendez, F; Navarrete-Marin, J J; Oller-Gonzalez, J C

    2003-01-01

    This document describes the design and construction of a NIR spectrometer based on an acoustic-optic tunable filter. The spectrometer will be used for automatic identification of plastics in domestic waste. The system works between 1200 and 1800 nm. Instrument is controlled by a personal computer. Computer receives and analyses data. A software package has been developed to do these tasks. (Author) 27 refs.

  13. Design and construction of a NIR spectrometer

    International Nuclear Information System (INIS)

    Barcala Riveira, J. M.; Fernandez Marron, J. L.; Alberdi Primicia, J.; Molero Menendez, F.; Navarrete Marin, J. J.; Oller Gonzalez, J. C.

    2003-01-01

    This document describes the design and construction of a NIR spectrometer based on an acoustic-optic tunable filter. The spectrometer will be used for automatic identification of plastics in domestic waste. The system works between 1200 and 1800 nm. Instrument is controlled by a personal computer. Computer receives and analyses data. A software package has been developed to do these tasks. (Author) 27 refs

  14. A digital control system for neutron spectrometers

    DEFF Research Database (Denmark)

    Hansen, Knud Bent; Skaarup, Per

    1968-01-01

    A description is given of the principles of a digital system used to control neutron spectrometers. The system is composed of independent functional units with the control programme stored on punched paper tape or in a computer.......A description is given of the principles of a digital system used to control neutron spectrometers. The system is composed of independent functional units with the control programme stored on punched paper tape or in a computer....

  15. Fast-response personal Moessbauer spectrometer

    International Nuclear Information System (INIS)

    Kholmetskij, A.L.; Mashlan, M.; Misevich, O.V.; Evdokimov, V.A.; Lopatik, A.R.; Zhak, D.; Fedorov, A.A.; Snashel, V.

    1995-01-01

    Spectrometer design to record transmission Moessbauer spectra is described. The spectrometer consists of PC/AT computer with 1 mb memory and 40 mb hard disk, of EPSON LX 850 printer, of color monitor with VGA graphical adapter, of data accumulation system, of speed generator, of motion system with minivibrator, of scintillation detector with YA10 3 :Ce scintillator, of single-channel amplitude analyzer, of measuring bench and of 57 Co(Rh) source. 1 ref.; 1 fig

  16. Muon momentum measurement in magnetized iron spectrometers

    International Nuclear Information System (INIS)

    Voss, R.; Zupancic, C.

    1984-01-01

    Measuring the momentum of high-energy muons with a magnetized iron spectrometer is a conventional technique employed by numerous experiments and may appear to be an old-fashioned subject. In the TeV regime, multiple scattering errors become small compared to measurement errors achieveable with large-surface particle detectors, and there are indications that new physical effects influencing the resolution properties of a muon spectrometer may become important. (orig./HSI)

  17. The BTeV main spectrometer

    International Nuclear Information System (INIS)

    Sheldon, P.D.

    2001-01-01

    BTeV is a second generation B-factory experiment that will use a double-arm, forward spectrometer in the C0 experimental hall at the Fermilab Tevatron. I will describe the motivation and design of the 'main spectrometer', consisting of a ring-imaging Cherenkov system for charged particle identification, an electromagnetic calorimeter of lead-tungstate crystals, a proportional tube muon system with magnetized filtering steel, and a straw-tube and silicon strip charged particle tracking system

  18. Ruggedized Spectrometers Are Built for Tough Jobs

    Science.gov (United States)

    2015-01-01

    The Mars Curiosity Chemistry and Camera instrument, or ChemCam, analyzes the elemental composition of materials on the Red Planet by using a spectrometer to measure the wavelengths of light they emit. Principal investigator Roger Wiens worked with Ocean Optics, out of Dunedin, Florida, to rework the company's spectrometer to operate in cold and rowdy conditions and also during the stresses of liftoff. Those improvements have been incorporated into the firm's commercial product line.

  19. Study of neutron spectrometers for ITER

    Energy Technology Data Exchange (ETDEWEB)

    Kaellne, Jan

    2005-11-15

    A review is presented of the developments in the field of neutron emission spectrometry (NES) which is of relevance for identifying the role of NES diagnostics on ITER and selecting suitable instrumentation. Neutron spectrometers will be part of the ITER neutron diagnostic complement and this study makes a special effort to examine which performance characteristics the spectrometers should possess to provide the best burning plasma diagnostic information together with neutron cameras and neutron yield monitors. The performance of NES diagnostics is coupled to how much interface space can be provided which has lead to an interest to find compact instruments and their NES capabilities. This study assesses all known spectrometer types of potential interest for ITER and makes a ranking of their performance (as demonstrated or projected), which, in turn, are compared with ITER measurement requirements as a reference; the ratio of diagnostic performance to interface cost for different spectrometers is also discussed for different spectrometer types. The overall result of the study is an assessment of which diagnostic functions neutron measurements can provide in burning plasma fusion experiments on ITER and the role that NES can play depending on the category of instrument installed. Of special note is the result that much higher quality diagnostic information can be obtained from neutron measurements with total yield monitors, profile flux cameras and spectrometers when the synergy in the data is considered in the analysis and interpretation.

  20. Ion guide quadrupole mass spectrometer at Jyvaeskylae

    International Nuclear Information System (INIS)

    Iivonen, A.; Saintola, R.; Valli, K.; Morita, K.; Yoshida, A.

    1991-01-01

    A new mass analyzing device consisting of an ion guide connected to a commercial quadrupole mass spectrometer is being developed at the Department of Physics, University of Jyvaeskylae. The new spectrometer is expected to have the similar properties to the present ion guide isotope separator on-line (IGISOL): excellent stability, similar separation efficiency for all chemical elements and short separation time. This ion guide mass spectrometer (IGQMS) is schematically shown. The IGQMS differs from the IGISOL in four essential ways: a squeezer ion guide, a differential pumping section, a transport section in which an electrostatic lens system brings ions into high vacuum, and a commercial quadrupole spectrometer used in place of a magnetic separator. The entire spectrometer became operational in the summer of 1990. The tests have been done with the alpha-active Po-215 ions released from an Ac-227 source in the target chamber. The squeezer, differential pumping section, transport section and quadrupole mass spectrometer of the IGQMS are described. The results of the measured transmission yield and the total yield of Po-215 and some merits of the IGQMS are reported. (K.I.)

  1. Recent ion optics and mass spectrometers

    International Nuclear Information System (INIS)

    Matsuda, Hisashi

    1976-01-01

    The establishment of the third order approximation method for computing the orbit of the ion optical system for mass spectrometers and the completion of its computer program are reported. A feature of this orbit computation is in that the effect of the fringing field can be considered with the accuracy of third order approximation. Several new ion optical systems for mass spectrometers have been proposed by using such orbit computing programs. Brief explanation and the description on the future prospect and problems are made on the following items: the vertual image double focusing mass spectrometer, the second order double focusing mass spectrometer, the E x B superposed field mass spectrometer, and the apparatus with a cylindrical electric field and Q-lens. In the E x B superposed field with Matsuda plates, if the magnetic field is generated by an electromagnet instead of a permanent magnet, the dispersion of mass and energy can be changed at will. The Matsuda plates are known as the auxiliary electrodes positioned at the top and bottom of a cylindrical capacitor. Utilizing those characteristics, a zoom spectrometer can be made, with which only a necessary part of mass spectra can be investigated in detail, but the whole spectra are investigated roughly. In addition, the distribution of energy can be investigated simultaneously after the separation of ionic mass similarly to the parabola apparatus. (Iwakiri, K.)

  2. Moessbauer spectrometer MsAa-3

    International Nuclear Information System (INIS)

    Gornicki, R.; Blachowski, A.; Ruebenbauer, K.

    2007-01-01

    The paper is aimed at the description of the newly developed Moessbauer spectrometer MsAa-3. The spectrometer MsAa-3 consists of a high quality γ--ray spectrometer including either a proportional gas detector head or a scintillation detector head, a transducer driving system including the transducer, data storage system, and data communication system based on the TCP/IP protocol. Additionally, the Michelson-Morley interferometer is provided for precise calibration of the transducer velocity. The spectrometer is equipped with an integrated simple temperature controller. All the essential functions are remotely controlled over the TCP/IP link allowing for the spectrometer set-up as the stand-alone unit in the computer network, e.g. on the Internet. External γ-ray detectors or external complete nuclear blocks could be used as well. The spectrometer is equipped with software allowing for setting all the functions, to perform on-line control, and retrieve data. The Moessbauer data processing software MOSGRAF is enclosed as well. The latter software allows for the calculation of the variety of velocity reference functions. (authors)

  3. Workplace innovation and social innovation : an introduction

    NARCIS (Netherlands)

    Jürgen Howaldt; Dr. Ben Fruytier; Peter R.A. Oeij; Steven Dhondt

    2016-01-01

    This is the introduction to the special issue of World Review of Entrepreneurship, Management and Sustainable Development (WREMSD) dedicated to workplace innovation and social innovation related to work and organisation. As technological and business model innovations alone are not sufficient to

  4. Workplace innovation and social innovation: an introduction

    NARCIS (Netherlands)

    Howaldt, J.; Oeij, P.R.A.; Dhondt, S.; Fruytier, B.

    2016-01-01

    This is the introduction to this special issue of World Review of Entrepreneurship, Management and Sustainable Development (WREMSD) dedicated to workplace innovation and social innovation related to work and organisation. As technological and business model innovations alone are not sufficient to

  5. Bridging conflicting innovation spheres of tourism innovation

    DEFF Research Database (Denmark)

    Fuglsang, Lars; Sørensen, Flemming; Nordli, Anne Jørgensen

    2016-01-01

    that in tourist destinations actors belong to conflicting innovation spheres but can be brought together in innovation processes when a diplomat enable compromises and when innovation spheres change from personalized to more generalized forms of activity during interaction. The findings are relevant not only...

  6. Challenging the Innovation Paradigm

    CERN Document Server

    Sveiby, Karl Erik; Segercrantz, Beata

    2012-01-01

    Innovation is almost always seen as a "good thing". Challenging the Innovation Paradigm is a critical analysis of the innovation frenzy and contemporary innovation research. The one-sided focus on desirable effects of innovation misses many opportunities to reduce the undesirable consequences. Authors in this book show how systemic effects outside the innovating firms reduce the net benefits of innovation for individual employees, customers, as well as for society as a whole - also the innovators' own organizations. This book analyzes the dominant discourses that construct and recons

  7. THOR Ion Mass Spectrometer (IMS)

    Science.gov (United States)

    Retinò, Alessandro

    2017-04-01

    Turbulence Heating ObserveR (THOR) is the first mission ever flown in space dedicated to plasma turbulence. The Ion Mass Spectrometer (IMS) onboard THOR will provide the first high-time resolution measurements of mass-resolved ions in near-Earth space, focusing on hot ions in the foreshock, shock and magnetosheath turbulent regions. These measurements are required to study how kinetic-scale turbulent fluctuations heat and accelerate different ion species. IMS will measure the full three-dimensional distribution functions of main ion species (H+, He++, O+) in the energy range 10 eV/q to 30 keV/q with energy resolution DE/E down to 10% and angular resolution down to 11.25˚ . The time resolution will be 150 ms for O+, 300 ms for He++ and ˜ 1s for O+, which correspond to ion scales in the the foreshock, shock and magnetosheath regions. Such high time resolution is achieved by mounting four identical IMS units phased by 90˚ in the spacecraft spin plane. Each IMS unit combines a top-hat electrostatic analyzer with deflectors at the entrance together with a time-of-flight section to perform mass selection. Adequate mass-per-charge resolution (M/q)/(ΔM/q) (≥ 8 for He++ and ≥ 3 for O+) is obtained through a 6 cm long Time-of-Flight (TOF) section. IMS electronics includes a fast sweeping high voltage board that is required to make measurements at high cadence. Ion detection includes Micro Channel Plates (MCPs) combined with Application-Specific Integrated Circuits (ASICs) for charge amplification and discrimination and a discrete Time-to-Amplitude Converter (TAC) to determine the ion time of flight. A processor board will be used to for ion events formatting and will interface with the Particle Processing Unit (PPU), which will perform data processing for THOR particle detectors. The IMS instrument is being designed and will be built and calibrated by an international consortium of scientific institutes from France, USA, Germany and Japan and Switzerland.

  8. Construction of a photoelectron spectrometer of hemispherical type

    International Nuclear Information System (INIS)

    Park, C.Y.; Kim, S.K.; Lee, D.W.

    1983-01-01

    We constructed the double focusing electron spectrometer for the ultraviolet photonelectron spectroscopy(UPS). The spectrometer is hemispherical type with the high resolution power with a vaule of about 100. The efficiency of the spectrometer was examined by the thermoelectron spectroscopy and UPS of the valence band of the Pd. It is merit of the present spectrometer that is very simple and small. (Author)

  9. Speeding Up Innovation

    DEFF Research Database (Denmark)

    Sørensen, Flemming; Mattsson, Jan

    2016-01-01

    Minimisation of time-to-market strategies can provide companies with a competitive advantage in dynamic and competitive environments. Using parallel innovation processes has been emphasised as one strategy to speed up innovation processes and consequently minimise the time-to-market of innovations....... Much innovation today takes place in open structures in which networks play an important role. However, little is known about how innovation networks can facilitate parallel innovation processes. This paper discusses how innovation network structures develop and support exploration and exploitation...... in parallel innovation processes and in this way sustain speedy innovation processes. A case study of an innovation network is carried out by analysing communication structures and the information contents of emails related to a particular innovation process. The analysis shows how certain characteristics...

  10. X-ray fluorescence analysis for trace element determination in foodstuff chemistry

    International Nuclear Information System (INIS)

    Wildanger, W.

    The physical fundamentals of X-ray fluorescence analysis are given and the routine spectrometers described. The basic principles are given of analytical methods used in qualitative and quantitative fluorescence analyses. Examples are given of the use of the method in a number of fields and the possibility and usefulness is discussed for the determination of trace elements in foodstuffs. The preparation of samples, preliminary concentration of components and calibration methods are discussed. (M.K.)

  11. Fluorescence staging laparoscopy for gastrointestinal malignancies: experimental experience

    Science.gov (United States)

    Prosst, Ruediger L.; Pietschmann, Mathias; Rheinwald, Markus; Haase, Thomas; Herfarth, Christian; Gahlen, Johannes

    2001-01-01

    Accurate staging can be a major problem in therapeutic planning of advanced abdominal malignancies. We experimentally combined conventional staging laparoscopy with aminolevulinic acid (ALA) induced fluorescence diagnosis (FD) to improve the detection of disseminated peritoneal tumors. Using different photosensitization times and ALA concentrations we evaluated the optimal fluorescence parameters for laparoscopic fluorescence diagnosis of intra abdominal tumor spread. In a rat tumor model we performed conventional and fluorescence laparoscopy to determine the increase of sensitivity gained by FD in terms of additionally detected lesions. After laparoscopic examination, the fluorescence emission from the tumors was spectrometically analyzed. Serum levels of ALA and PpIX were measured by HPLC to determine their systemic metabolism. Fluorescence staging laparoscopy was able to visualize even macroscopically occult neoplasms. Using 1.5 percent ALA solution and a photosensitization time of 4 hours as favorable parameters the diagnostic value of conventional staging laparoscopy was significantly improved: 35 percent of all malignant lesions were detected only by FD. Therefore, fluorescence laparoscopy suggest to be a highly promising preoperative staging tool requiring minimal technical and clinical expenditure. It provides the laparoscopist with a rapid and accurate technique to assess more thoroughly the full extent of malignant tumor growth in the abdominal cavity.

  12. The LASS [Larger Aperture Superconducting Solenoid] spectrometer

    International Nuclear Information System (INIS)

    Aston, D.; Awaji, N.; Barnett, B.

    1986-04-01

    LASS is the acronym for the Large Aperture Superconducting Solenoid spectrometer which is located in an rf-separated hadron beam at the Stanford Linear Accelerator Center. This spectrometer was constructed in order to perform high statistics studies of multiparticle final states produced in hadron reactions. Such reactions are frequently characterized by events having complicated topologies and/or relatively high particle multiplicity. Their detailed study requires a spectrometer which can provide good resolution in momentum and position over almost the entire solid angle subtended by the production point. In addition, good final state particle identification must be available so that separation of the many kinematically-overlapping final states can be achieved. Precise analyses of the individual reaction channels require high statistics, so that the spectrometer must be capable of high data-taking rates in order that such samples can be acquired in a reasonable running time. Finally, the spectrometer must be complemented by a sophisticated off-line analysis package which efficiently finds tracks, recognizes and fits event topologies and correctly associates the available particle identification information. This, together with complicated programs which perform specific analysis tasks such as partial wave analysis, requires a great deal of software effort allied to a very large computing capacity. This paper describes the construction and performance of the LASS spectrometer, which is an attempt to realize the features just discussed. The configuration of the spectrometer corresponds to the data-taking on K + and K - interactions in hydrogen at 11 GeV/c which took place in 1981 and 1982. This constitutes a major upgrade of the configuration used to acquire lower statistics data on 11 GeV/c K - p interactions during 1977 and 1978, which is also described briefly

  13. The LASS (Larger Aperture Superconducting Solenoid) spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Aston, D.; Awaji, N.; Barnett, B.; Bienz, T.; Bierce, R.; Bird, F.; Bird, L.; Blockus, D.; Carnegie, R.K.; Chien, C.Y.

    1986-04-01

    LASS is the acronym for the Large Aperture Superconducting Solenoid spectrometer which is located in an rf-separated hadron beam at the Stanford Linear Accelerator Center. This spectrometer was constructed in order to perform high statistics studies of multiparticle final states produced in hadron reactions. Such reactions are frequently characterized by events having complicated topologies and/or relatively high particle multiplicity. Their detailed study requires a spectrometer which can provide good resolution in momentum and position over almost the entire solid angle subtended by the production point. In addition, good final state particle identification must be available so that separation of the many kinematically-overlapping final states can be achieved. Precise analyses of the individual reaction channels require high statistics, so that the spectrometer must be capable of high data-taking rates in order that such samples can be acquired in a reasonable running time. Finally, the spectrometer must be complemented by a sophisticated off-line analysis package which efficiently finds tracks, recognizes and fits event topologies and correctly associates the available particle identification information. This, together with complicated programs which perform specific analysis tasks such as partial wave analysis, requires a great deal of software effort allied to a very large computing capacity. This paper describes the construction and performance of the LASS spectrometer, which is an attempt to realize the features just discussed. The configuration of the spectrometer corresponds to the data-taking on K and K interactions in hydrogen at 11 GeV/c which took place in 1981 and 1982. This constitutes a major upgrade of the configuration used to acquire lower statistics data on 11 GeV/c K p interactions during 1977 and 1978, which is also described briefly.

  14. Fluorescent minerals, a review

    Science.gov (United States)

    Modreski, P.J.; Aumente-Modreski, R.

    1996-01-01

    Fluorescent minerals are more than just an attractive novelty, and collecting them is a speciality for thousands of individuals who appreciate their beauty, rarity, and scientific value. Fluorescent properties can be used as an aid to mineral identification, locality determination, and distinction between natural and synthetic gemstones. This article gives an overview of those aspects of fluorescence that are of most interest to collectors, hobbyists, and mineralogists. -from Authors

  15. Application of x-ray fluorescence Spectrometry to the evaluation of heavy metal Pollution in the region of meknes (morocco)

    International Nuclear Information System (INIS)

    Rahmani, A.; Benyai Ch, F.; Bounakhla, M.; Zahry, F.; Bilal, E.; Moutte, J.; Gruffat, J.

    2001-01-01

    In this work we present the performances and capabilities of the energy Dispersive X-ray fluorescence (ED-XRF) spectrometers at the National Center For the Nuclear Energy, Sciences and Techniques (CNESTEN, Rabat, Morocco). These spectrometers are configured around a Si(Li) detector and use either radioisotope Excitation radioactive ( 55 Fe, 109 Cd and 241 Am radioactive sources) or Secondary target X-ray tube excitation (using Mo and Cu secondary targets). The Analytical results of these spectrometers were compared to those of the wave length Dispersive X-ray fluorescence (WD-XRF) spectrometer at the Ecole des Mines de St Etienne (France). This comparison was carried out using reference materials Samples from the International Atomic Energy Agency (IAEA). The data of such comparison showed that the present experimental setup of the spectrometers, allowed to reproduce the certified values with an accuracy of 5 % for major elements and of 10 to 20 % for trace elements. This intercomparison Showed also the advantages of each of the spectrometers. The WD-XRF Spectrometer being more sensitive at low X-ray energies, while the ED-XRF Spectrometer is more efficient for quantification of trace elements. As an application, we also present the preliminary results obtained in using These techniques for the evaluation of the heavy metal pollution induced by the use For irrigation purpose, of waters loaded with urban and industrial waste waters, in The region of Meknes (Morocco)

  16. Atomic-fluorescence spectrophotometry

    International Nuclear Information System (INIS)

    Bakhturova, N.F.; Yudelevich, I.G.

    1975-01-01

    Atomic-fluorescence spectrophotometry, a comparatively new method for the analysis of trace quantities, has developed rapidly in the past ten years. Theoretical and experimental studies by many workers have shown that atomic-fluorescence spectrophotometry (AFS) is capable of achieving a better limit than atomic absorption for a large number of elements. The present review examines briefly the principles of atomic-fluorescence spectrophotometry and the types of fluorescent transition. The excitation sources, flame and nonflame atomizers, used in AFS are described. The limits of detection achieved up to the present, using flame and nonflame methods of atomization are given

  17. User Innovation Management

    DEFF Research Database (Denmark)

    Kanstrup, Anne Marie; Bertelsen, Pernille

    User Innovation Management (UIM) is a method for fo-opereation with users in innovation projects. The UIM method emphasizes the practice of a participatorty attitude.......User Innovation Management (UIM) is a method for fo-opereation with users in innovation projects. The UIM method emphasizes the practice of a participatorty attitude....

  18. Innovation fri for floskler

    DEFF Research Database (Denmark)

    Bukh, Per Nikolaj

    2009-01-01

    Anmeldelse af Roberto Verganti, 2009, Design-Driven Innovation: Changing the Rules of Competition by Radically Innovating what things mean, Harvard Business Press. Udgivelsesdato: 27. november......Anmeldelse af Roberto Verganti, 2009, Design-Driven Innovation: Changing the Rules of Competition by Radically Innovating what things mean, Harvard Business Press. Udgivelsesdato: 27. november...

  19. Education and Social Innovation

    DEFF Research Database (Denmark)

    Rasmussen, Palle

    The working paper is an attempt to structure the issue of education and social innovation and indicate topics that can be investigated further. Three aspects are outlined, the contribution of social innovation in educational provision, the educative dimension of social innovation and the issue...... of education for social innovation....

  20. Entrepreneurship, Innovation and Institutions

    NARCIS (Netherlands)

    Stam, E.; Nooteboom, B.

    2011-01-01

    This paper discusses the nature of entrepreneurship and its relation to innovation along a cycle in which exploration and exploration follow upon each other. We place the roles of entrepreneurship in innovation policy within this cycle of innovation. Different types of innovation along the cycle of

  1. Time-of-flight isochronous spectrometer

    International Nuclear Information System (INIS)

    Wouters, J.M.; Vieira, D.J.; Wollnik, H.

    1985-01-01

    This report is the second in a series of progress reports describing the design and construction of the time-of-flight isochronous (TOFI) spectrometer and its associated secondary beam line. TOFI, which is being constructed jointly by INC and MP Divisions, is designed to measure in a systematic fashion the ground-state masses of the light neutron-rich nuclei with A<70 that lie far from the valley of β stability. In the past year the authors ordered all the long-lead items necessary for construction of the spectrometer and installed the first half of the secondary beam line. Furthermore, a major portion of the control system for both the spectrometer and beam line was designed and installed. This annual report briefly summarizes the current status of the spectrometer and describes in some detail the design and installation of the first half of the transport line. For a summary of the scientific goals and overall design of the TOFI spectrometer, see the 1983 Progress at LAMPF report

  2. Making Collaborative Innovation Accountable

    DEFF Research Database (Denmark)

    Sørensen, Eva

    The public sector is increasingly expected to be innovative, but the prize for a more innovative public sector might be that it becomes difficult to hold public authorities to account for their actions. The article explores the tensions between innovative and accountable governance, describes the...... the foundation for these tensions in different accountability models, and suggest directions to take in analyzing the accountability of collaborative innovation processes.......The public sector is increasingly expected to be innovative, but the prize for a more innovative public sector might be that it becomes difficult to hold public authorities to account for their actions. The article explores the tensions between innovative and accountable governance, describes...

  3. Innovation Across the Supply Chain

    DEFF Research Database (Denmark)

    Druehl, Cheryl; Carrillo, Janice; Hsuan, Juliana

    Innovation is an integral part of every firm’s ongoing operations. Beyond product innovation, supply chain innovations offer a unique source of competitive advantage. We synthesize recent research on innovation in the supply chain, specifically, innovative supply chain processes...

  4. Use of a Superconducting Tunnel Junction for X-Ray Fluorescence Spectroscopy

    International Nuclear Information System (INIS)

    Hiller, L.

    2001-01-01

    A superconducting tunnel junction (STJ) in combination with a superconducting absorber of radiation may function as a highly resolving x-ray spectrometer. Electronic excitations, or quasiparticles, are created when a superconductor absorbs an x ray and are detected as an excess tunnel current through the junction. The number of quasiparticles created and the magnitude of the excess current is proportional to the energy of the absorbed x ray. This is similar to existing semiconductor-based spectrometers that measure electron-hole pairs, but with 1000 times more excitations. The energy measurement therefore can be up to 30 times more precise with a superconducting detector than with a semiconductor detector. This work describes the development and testing of an STJ spectrometer design for x-ray fluorescence applications. First, the basic principles of the STJ spectrometer are explained. This is followed by detailed simulations of the variance in the number of quasiparticles produced by absorption of an x ray. This variance is inherent in the detector and establishes an upper limit on the resolving power of the spectrometer. These simulations include effects due to the materials used in the spectrometer and to the multilayer structure of the device. Next, the spectrometer is characterized as functions of operating temperature, incident x-ray energy, and count rate. Many of these tests were performed with the spectrometer attached to a synchrotron radiation port. Finally, example x-ray fluorescence spectra of materials exposed to synchrotron radiation are presented. These materials are of interest to semiconductor processing and structural biology, two fields that will benefit immediately from the improved resolving power of the STJ spectrometer

  5. Fluorescence-Activated Cell Sorting of Live Versus Dead Bacterial Cells and Spores

    Science.gov (United States)

    Bernardini, James N.; LaDuc, Myron T.; Diamond, Rochelle; Verceles, Josh

    2012-01-01

    This innovation is a coupled fluorescence-activated cell sorting (FACS) and fluorescent staining technology for purifying (removing cells from sampling matrices), separating (based on size, density, morphology, and live versus dead), and concentrating cells (spores, prokaryotic, eukaryotic) from an environmental sample.

  6. Socio-Ecological Innovation

    DEFF Research Database (Denmark)

    Edgeman, Rick; Eskildsen, Jacob Kjær

    is part of the enterprise cultural fabric, is foundational to enterprise strategy, and contributes to the financial security of the enterprise. Innovation for Sustainability is innovation that is specifically targeted to address ecological and / or societal considerations. That is, Innovation......Socio‐Ecological Innovation or SEI is innovation resulting from strategic integration of sustainable innovation and innovation for sustainability. In particular SEI is regarded as critical to organizations intent on progressing toward Sustainable Enterprise Excellence (SEE) and, indeed, progressing...... toward the asymptotic goal of becoming a continuously relevant and responsible organization (CR2O). Sustainable Innovation is something that is attained only when innovation in an enterprise is regular, systematic, and systemic to the endeavors of the enterprise itself – that is – Sustainable Innovation...

  7. Ultratrace analysis of actinides via coprecipitation/laser-induced fluorescence spectroscopy

    International Nuclear Information System (INIS)

    Miller, S.M.

    1982-01-01

    Actinides were selectively preconcentrated by coprecipitating each out of solution with a fluoride matrix and calcining each sample at 800 0 C. The fluorescence spectrum of each sample was recorded by illuminating the sample with laser light and detecting fluorescence with either a fluorescence/Raman spectrometer, an infrared spectrometer or in certain cases a filter fluorimeter. Three previously unobserved actinide spectra were recorded. Narrow lines at 546.9 nm, 564.6 nm, and 569.6 nm were found for CaF 2 :PuO 2++ at 10K. CaF 2 :Am + 3 displayed two broadband fluorescent peaks at 625 nm and 746 nm at room temperature and CaF 2 :Pu + 3 possessed a fluorescent peak at 1.22 microns at 10K. Energy transfer was observed in the form of Tb fluorescence quenching in TbF 3 :Pu + 3 when Pu was present in quantities of 10 ppM or more and in the form of Tb fluorescence enhancement in TbF 3 :Am + 3 when 1 ppM or more of Am was present. Careful sample preparation and the use of temporal as well as a spectral discrimination system extended the detection limit of U from 1 ml samples to the subfemtogram level. The fluorescence detection limits for Pu and Am were extended to 0.48 and 0.032 pg/ml. 39 figures, 9 tables

  8. Innovative characterization, monitoring and sensor technologies for environmental radioactivity at USDOE sites

    International Nuclear Information System (INIS)

    Hutter, A.; Weeks, S.

    2001-01-01

    The mission of the U.S. Department of Energy Office of Environmental Management (EM) is to clean up its contaminated sites from the past production of nuclear weapons. Within EM, the Office of Science and Technology (OST) is responsible for providing a full range of science and technology resources needed to support resolution of EM cleanup and long-term environmental stewardship problems. This responsibility includes implementation of a technology development pathway from basic research to development, demonstration, and deployment of scientific and technological solutions needed by DOE sites. One OST Program is the Characterization, Monitoring, and Sensor Technology Crosscutting Program (CMST-CP), which aims to provide innovative technologies (i.e., faster, better, cheaper, and/or safer) for environmental characterization and monitoring. Several technologies are described that CMST-CP has supported for development with significant benefits realized or projected over the baseline characterization and monitoring practices. Examples of these technologies include mapping of subsurface radioactivity using Cone Penetrometer and drilling techniques; a Rapid Liquid Sampler for Sr, Ra, Tc, and Cs using 3M Empore TM Rad Disks; Long-Range Alpha Detectors; a Compact High Resolution Spectrometer; BetaScint TM for determination of Sr in soil; Laser-Induced Fluorescence Imaging techniques for mapping U on surfaces; the Environmental Measurements While Drilling System; and the Expedited Site Characterization methodology. (author)

  9. Systems of Innovation

    OpenAIRE

    Soete, Luc; Verspagen, Bart; Weel, Bas ter

    2009-01-01

    We review the literature on national innovation systems. We first focus on the emergence of the concept of innovation systems, reviewing its historical origins and three main flavours (associated to three “founding fathers†of the concept). After this, we discuss how the notion of innovation systems filled a need for providing a broader basis for innovation policy. We conclude with some perspectives on the future of the innovation systems literature.

  10. STRATEGIC INNOVATION APPROACH

    OpenAIRE

    Dogan, Nilhun

    2017-01-01

    In recentyears, the concept of innovation has become the most debated topic inliterature and in particular, the strategic importance of innovation managementfor businesses is emphasized. In this context, the strategic innovationapproach, which emerged as a synergy of innovation and strategic management,seems to play an important role in achieving sustainable competitive advantage.The aim of this article is to emphasize the importance of innovation andstrategic innovation approach.  

  11. Adaptive Tunable Laser Spectrometer for Space Applications

    Science.gov (United States)

    Flesch, Gregory; Keymeulen, Didier

    2010-01-01

    An architecture and process for the rapid prototyping and subsequent development of an adaptive tunable laser absorption spectrometer (TLS) are described. Our digital hardware/firmware/software platform is both reconfigurable at design time as well as autonomously adaptive in real-time for both post-integration and post-launch situations. The design expands the range of viable target environments and enhances tunable laser spectrometer performance in extreme and even unpredictable environments. Through rapid prototyping with a commercial RTOS/FPGA platform, we have implemented a fully operational tunable laser spectrometer (using a highly sensitive second harmonic technique). With this prototype, we have demonstrated autonomous real-time adaptivity in the lab with simulated extreme environments.

  12. Magnetic field measurements of the BLAST spectrometer

    International Nuclear Information System (INIS)

    Dow, Karen A.; Botto, Tancredi; Goodhue, Abigail; Hasell, Douglas; Loughnan, Dylan; Murphy, Kilian; Smith, Timothy Paul; Ziskin, Vitaliy

    2009-01-01

    The Bates Large Acceptance Spectrometer Toroid has been built to study nuclear physics reactions using a stored, polarized electron beam and a variety of polarized targets internal to the storage ring. The spectrometer consists of eight coils surrounding the target cell. There is a requirement of nominally zero field along the centerline of the spectrometer for proper electron beam storage. In addition, the polarized internal targets require a low field gradient in the target region. Magnetic field measurements were made near the beam centerline to guide the alignment of the coils and satisfy the field magnitude and gradient requirements. After the coils were aligned, the magnetic field was measured in the detector regions to provide information for particle tracking.

  13. SPEG: An energy loss spectrometer for GANIL

    Science.gov (United States)

    Bianchi, L.; Fernandez, B.; Gastebois, J.; Gillibert, A.; Mittig, W.; Barrette, J.

    1989-04-01

    Since July 1985, an energy loss spectrometer (SPEG) is under operation at the National Heavy Ion Laboratory (GANIL), at Caen (France). It has been designed to allow the study of quantum states populated in reactions induced by nuclei accelerated at energies up to 100 A MeV. The spectrometer has been designed by P. Birien. The optical properties and the main magnetic features have been calculated by Birien and Valero. A detailed reported of their study is given in ref. [1]. In the first part of the present paper, after recalling the specifications of the spectrometer, we shall give an overall description of the main characteristics, together with indications about the various shimming procedures which have been used to achieve the desired resolution (sections 1-4). In the second part, we shall describe various accessories and the different kinds of detectors which are used during experiments, with several illustrations of experimental results (sections 5 and 6).

  14. An EUV spectrometer for atmospheric remote sensing

    International Nuclear Information System (INIS)

    Chakrabarti, S.; Cotton, D.M.; Lampton, M.; Siegmund, O.H.W.; Link, R.

    1989-01-01

    This paper describes the Berkeley EUV Airglow Rocket Spectrometer (BEARS) experiment, designed to investigate the interactions between the solar ionizing radiation and the earth's upper atmosphere. The primary objective of this experiment is the verification the feasibility of using EUV observations as a quantitative diagnostic of the terrestrial atmosphere and its plasma environment. The expected information provided by spectroscopic measurements of EUV emission will include data on the excitation mechanisms, excitation rates, and branching ratios. The BEARS experimental package consists of a high-resolution EUV airglow spectrometer, a hydrogen Lyman-alpha photometer to measure both the solar radiations and the geocoronal emissions, and a moderate-resolution solar EUV spectrometer. In a test experiment, the instruments were carried aboard a four-stage sounding rocket to a peak altitude of about 960 km and obtained airglow spectra in the 980-1060 A range and in the 1300-1360 range. 34 refs

  15. Landsat-Swath Imaging Spectrometer Design

    Science.gov (United States)

    Mouroulis, Pantazis; Green, Robert O.; Van Gorp, Byron; Moore, Lori; Wilson, Daniel W.; Bender, Holly A.

    2015-01-01

    We describe the design of a high-throughput pushbroom imaging spectrometer and telescope system that is capable of Landsat swath and resolution while providing better than 10 nm per pixel spectral resolution. The design is based on a 3200 x 480 element x 18 µm pixel size focal plane array, two of which are utilized to cover the full swath. At an optical speed of F/1.8, the system is the fastest proposed to date to our knowledge. The utilization of only two spectrometer modules fed from the same telescope reduces system complexity while providing a solution within achievable detector technology. Predictions of complete system response are shown. Also, it is shown that detailed ghost analysis is a requirement for this type of spectrometer and forms an essential part of a complete design.

  16. A compact multichannel spectrometer for Thomson scattering.

    Science.gov (United States)

    Schoenbeck, N L; Schlossberg, D J; Dowd, A S; Fonck, R J; Winz, G R

    2012-10-01

    The availability of high-efficiency volume phase holographic (VPH) gratings and intensified CCD (ICCD) cameras have motivated a simplified, compact spectrometer for Thomson scattering detection. Measurements of T(e) VPH grating and measurements T(e) > 100 eV by a 2072 l∕mm VPH grating. The spectrometer uses a fast-gated (~2 ns) ICCD camera for detection. A Gen III image intensifier provides ~45% quantum efficiency in the visible region. The total read noise of the image is reduced by on-chip binning of the CCD to match the 8 spatial channels and the 10 spectral bins on the camera. Three spectrometers provide a minimum of 12 spatial channels and 12 channels for background subtraction.

  17. A compact multichannel spectrometer for Thomson scatteringa)

    Science.gov (United States)

    Schoenbeck, N. L.; Schlossberg, D. J.; Dowd, A. S.; Fonck, R. J.; Winz, G. R.

    2012-10-01

    The availability of high-efficiency volume phase holographic (VPH) gratings and intensified CCD (ICCD) cameras have motivated a simplified, compact spectrometer for Thomson scattering detection. Measurements of Te VPH grating and measurements Te > 100 eV by a 2072 l/mm VPH grating. The spectrometer uses a fast-gated (˜2 ns) ICCD camera for detection. A Gen III image intensifier provides ˜45% quantum efficiency in the visible region. The total read noise of the image is reduced by on-chip binning of the CCD to match the 8 spatial channels and the 10 spectral bins on the camera. Three spectrometers provide a minimum of 12 spatial channels and 12 channels for background subtraction.

  18. Prismatic analyzer concept for neutron spectrometers

    DEFF Research Database (Denmark)

    Birk, Jonas O.; Marko, M.; Freeman, P.G.

    2014-01-01

    Developments in modern neutron spectroscopy have led to typical sample sizes decreasing from few cm to several mm in diameter samples. We demonstrate how small samples together with the right choice of analyser and detector components makes distance collimation an important concept in crystal...... analyser spectrometers. We further show that this opens new possibilities where neutrons with different energies are reflected by the same analyser but counted in different detectors, thus improving both energy resolution and total count rate compared to conventional spectrometers. The technique can...... inverse geometry Time-of-flight spectrometer installed at PSI, Switzerland, and shows excellent agreement with the predictions. Typical improvements will be 2.0 times finer resolution and a factor of 1.9 in flux gain compared to a focussing Rowland geometry, or of 3.3 times finer resolution and a factor...

  19. A compact multichannel spectrometer for Thomson scattering

    Energy Technology Data Exchange (ETDEWEB)

    Schoenbeck, N. L.; Schlossberg, D. J.; Dowd, A. S.; Fonck, R. J.; Winz, G. R. [Department of Engineering Physics, University of Wisconsin, Madison, Wisconsin 53706 (United States)

    2012-10-15

    The availability of high-efficiency volume phase holographic (VPH) gratings and intensified CCD (ICCD) cameras have motivated a simplified, compact spectrometer for Thomson scattering detection. Measurements of T{sub e} < 100 eV are achieved by a 2971 l/mm VPH grating and measurements T{sub e} > 100 eV by a 2072 l/mm VPH grating. The spectrometer uses a fast-gated ({approx}2 ns) ICCD camera for detection. A Gen III image intensifier provides {approx}45% quantum efficiency in the visible region. The total read noise of the image is reduced by on-chip binning of the CCD to match the 8 spatial channels and the 10 spectral bins on the camera. Three spectrometers provide a minimum of 12 spatial channels and 12 channels for background subtraction.

  20. Medical innovation laws: an unnecessary innovation.

    Science.gov (United States)

    Richards, Bernadette

    2016-06-01

    Objective This paper aims to demonstrate that any suggestion that there is a need for specific innovation laws is flawed. Innovation is central to good medical practice and is adequately supported by current law. Methods The paper reviews the nature of medical innovation and outlines recent attempts in the UK to introduce specific laws aimed at 'encouraging' and 'supporting' innovation. The current legal framework is outlined and the role of the law in relation to medical innovation explored. Results The analysis demonstrates the cyclic relationship between medical advancement and the law and concludes that there is no requirement for specific innovation laws. Conclusions The law not only supports innovation and development in medical treatment but encourages it as central to a functioning medical system. There is no need to introduce specific laws aimed at medical innovation; to do so represents an unnecessary legal innovation and serves to complicate matters. What is known about the topic? Over recent months, there has been a great deal of discussion surrounding the law in the context of medical innovation. This was driven by the attempts in the UK to introduce specific laws in the Medical Innovation Bill. The general subject matter - negligence and the expected standard of care in the provision of treatment - is very well understood, but not in cases where the treatment can be described as innovative. The general rhetoric in both the UK and Australia around the Medical Innovation Bill demonstrates a lack of understanding of the position of the law with regards to innovative treatment. What does this paper add? This paper adds clarity to the debate. It presents the law and explains the manner in which the law can operate around innovative treatment. The paper asserts that medical innovation is both supported and encouraged by existing legal principles. What are the implications for practitioners? The paper presents an argument that can guide the policy position

  1. Reflection zone plate wavelength-dispersive spectrometer for ultra-light elements measurements.

    Science.gov (United States)

    Hafner, Aljoša; Anklamm, Lars; Firsov, Anatoly; Firsov, Alexander; Löchel, Heike; Sokolov, Andrey; Gubzhokov, Renat; Erko, Alexei

    2015-11-16

    We have developed an electron beam excitation ultra-soft X-ray add-on device for a scanning electron microscope with a reflective zone plate mulichannel spectrometer in order to analyse ultra-light elements such as Li and B. This spectrometer has high (λ/Δλ~100) resolving power in the energy range of 45 eV - 1120 eV. Metallic Li samples were examined and fluorescence spectra successfully measured. Energy resolution of 0.49 eV was measured in the ultra-low energy range using the Al L(2,3) line at 71 eV. High sensitivity of Boron detection was demonstrated on a B(4)C sample with layer thicknesses of 1-50 nm, detecting an amount of metallic Boron as small as ~0.57 fg.

  2. First results from the new double velocity-double energy spectrometer VERDI

    Science.gov (United States)

    Frégeau, M. O.; Oberstedt, S.; Gamboni, Th.; Geerts, W.; Hambsch, F.-J.; Vidali, M.

    2016-05-01

    The VERDI spectrometer (VElocity foR Direct mass Identification) is a two arm time-of-flight spectrometer built at the European Commission Joint Research Centre IRMM. It determines fragment masses and kinetic energy distributions produced in nuclear fission by means of the double velocity and double energy (2v-2E) method. The simultaneous measurement of pre- and post neutron fragment characteristics allows studying the share of excitation energy between the two fragments. In particular, the evolution of fission modes and neutron multiplicity may be studied as a function of the available excitation energy. Both topics are of great importance for the development of models used in the evaluation of nuclear data, and also have important implications for the fundamental understanding of the fission process. The development of VERDI focus on maximum geometrical efficiency while striving for highest possible mass resolution. An innovative transmission start detector, using electrons ejected from the target itself, was developed. Stop signal and kinetic energy of both fragments are provided by two arrays of silicon detectors. The present design provides about 200 times higher geometrical efficiency than that of the famous COSI FAN TUTTE spectrometer [Nuclear Instruments and Methods in Physics Research 219 (1984) 569]. We report about a commissioning experiment of the VERDI spectrometer, present first results from a 2v-2E measurement of 252Cf spontaneous fission and discuss the potential of this instrument to contribute to the investigation prompt fission neutron characteristics as a function of fission fragment properties.

  3. First results from the new double velocity–double energy spectrometer VERDI

    Energy Technology Data Exchange (ETDEWEB)

    Frégeau, M.O.; Oberstedt, S., E-mail: stephan.oberstedt@ec.europa.eu; Gamboni, Th.; Geerts, W.; Hambsch, F.-J.; Vidali, M.

    2016-05-01

    The VERDI spectrometer (VElocity foR Direct mass Identification) is a two arm time-of-flight spectrometer built at the European Commission Joint Research Centre IRMM. It determines fragment masses and kinetic energy distributions produced in nuclear fission by means of the double velocity and double energy (2v–2E) method. The simultaneous measurement of pre- and post neutron fragment characteristics allows studying the share of excitation energy between the two fragments. In particular, the evolution of fission modes and neutron multiplicity may be studied as a function of the available excitation energy. Both topics are of great importance for the development of models used in the evaluation of nuclear data, and also have important implications for the fundamental understanding of the fission process. The development of VERDI focus on maximum geometrical efficiency while striving for highest possible mass resolution. An innovative transmission start detector, using electrons ejected from the target itself, was developed. Stop signal and kinetic energy of both fragments are provided by two arrays of silicon detectors. The present design provides about 200 times higher geometrical efficiency than that of the famous COSI FAN TUTTE spectrometer [Nuclear Instruments and Methods in Physics Research 219 (1984) 569]. We report about a commissioning experiment of the VERDI spectrometer, present first results from a 2v-2E measurement of {sup 252}Cf spontaneous fission and discuss the potential of this instrument to contribute to the investigation prompt fission neutron characteristics as a function of fission fragment properties.

  4. Multimodal fluorescence imaging spectroscopy

    NARCIS (Netherlands)

    Stopel, Martijn H W; Blum, Christian; Subramaniam, Vinod; Engelborghs, Yves; Visser, Anthonie J.W.G.

    2014-01-01

    Multimodal fluorescence imaging is a versatile method that has a wide application range from biological studies to materials science. Typical observables in multimodal fluorescence imaging are intensity, lifetime, excitation, and emission spectra which are recorded at chosen locations at the sample.

  5. Wide size range fast integrated mobility spectrometer

    Science.gov (United States)

    Wang, Jian

    2013-10-29

    A mobility spectrometer to measure a nanometer particle size distribution is disclosed. The mobility spectrometer includes a conduit and a detector. The conduit is configured to receive and provide fluid communication of a fluid stream having a charged nanometer particle mixture. The conduit includes a separator section configured to generate an electrical field of two dimensions transverse to a dimension associated with the flow of the charged nanometer particle mixture through the separator section to spatially separate charged nanometer particles of the charged nanometer particle mixture in said two dimensions. The detector is disposed downstream of the conduit to detect concentration and position of the spatially-separated nanometer particles.

  6. Spectrometer Baseline Control Via Spatial Filtering

    Science.gov (United States)

    Burleigh, M. R.; Richey, C. R.; Rinehart, S. A.; Quijada, M. A.; Wollack, E. J.

    2016-01-01

    An absorptive half-moon aperture mask is experimentally explored as a broad-bandwidth means of eliminating spurious spectral features arising from reprocessed radiation in an infrared Fourier transform spectrometer. In the presence of the spatial filter, an order of magnitude improvement in the fidelity of the spectrometer baseline is observed. The method is readily accommodated within the context of commonly employed instrument configurations and leads to a factor of two reduction in optical throughput. A detailed discussion of the underlying mechanism and limitations of the method are provided.

  7. Upgrade of an old Raman Spectrometer

    DEFF Research Database (Denmark)

    Hansen, Susanne Brunsgaard; Berg, Rolf W.; Stenby, Erling Halfdan

    2004-01-01

    Improvement of a conventional Jeol Raman spectrometer with a single channel photo multiplier detector is described. New optical components (fibres, mirror, lens and CCD detector) have been chosen to design a high quality and easy-to-use instrument. Tests have shown that with this modified...... spectrometer Raman spectra can be acquired of a quality comparable to the spectra obtained previously, but the time needed to obtain a spectrum is markedly reduced. Selected test spectra and a simple calibration procedure to obtain the wavenumber values from the band CCD pixel position are presented....

  8. An efficient gravitational spectrometer for ultracold neutrons

    International Nuclear Information System (INIS)

    Geltenbort, P.; Goeltl, L.; Henneck, R.; Horras, M.; Kirch, K.; Knecht, A.; Lauss, B.; Meier, M.; Straumann, U.; Zsigmond, G.

    2010-01-01

    We report on the design and construction of an efficient gravitational spectrometer for ultracold neutrons. The spectrometer is suited to experiments that can greatly profit from knowledge of the neutron energy spectrum without losing available statistics, such as many of the current precision experiments that use ultracold neutrons. The description of the apparatus is complemented by the results of the first test measurements which served as a proof of principle and showed its capability of discriminating between different UCN energy ranges. The measurements showed the expected behavior and are in qualitative agreement with Monte Carlo simulations.

  9. An efficient gravitational spectrometer for ultracold neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Geltenbort, P. [Institut Laue-Langevin, Grenoble (France); Goeltl, L. [Paul Scherrer Institut, PSI, Villigen (Switzerland); ETH Zuerich, Zuerich (Switzerland); Henneck, R. [Paul Scherrer Institut, PSI, Villigen (Switzerland); Horras, M. [Paul Scherrer Institut, PSI, Villigen (Switzerland); Excellence Cluster ' Universe' , Technische Universitaet Muenchen, Garching (Germany); Kirch, K., E-mail: klaus.kirch@psi.c [Paul Scherrer Institut, PSI, Villigen (Switzerland); ETH Zuerich, Zuerich (Switzerland); Knecht, A., E-mail: a.knecht@psi.c [Paul Scherrer Institut, PSI, Villigen (Switzerland); University of Zuerich, Zuerich (Switzerland); ETH Zuerich, Zuerich (Switzerland); Lauss, B.; Meier, M. [Paul Scherrer Institut, PSI, Villigen (Switzerland); Straumann, U. [University of Zuerich, Zuerich (Switzerland); Zsigmond, G. [Paul Scherrer Institut, PSI, Villigen (Switzerland)

    2010-12-01

    We report on the design and construction of an efficient gravitational spectrometer for ultracold neutrons. The spectrometer is suited to experiments that can greatly profit from knowledge of the neutron energy spectrum without losing available statistics, such as many of the current precision experiments that use ultracold neutrons. The description of the apparatus is complemented by the results of the first test measurements which served as a proof of principle and showed its capability of discriminating between different UCN energy ranges. The measurements showed the expected behavior and are in qualitative agreement with Monte Carlo simulations.

  10. Large acceptance spectrometers for π0 mesons

    International Nuclear Information System (INIS)

    Awes, T.C.; Ferguson, R.L.; Obenshain, F.E.

    1984-01-01

    A spectrometer composed of lead-oxide loaded glass blocks has been constructed for detection of neutral pi mesons emitted in low energy heavy ion reactions. The spectrometer detects the Cerenkov radiation emitted when the high energy photons (Eγ approx. 70 MeV) resulting from π 0 decay create electron-position pairs in the glass, initiating electromagnetic showers. A geometric acceptance of better than 5% of 4π is possible; the π 0 detection efficiency varies between this value at T/sub π/ = 0 MeV and 1% for T/sub π/ approx. 100 MeV

  11. Precision evaluation of pressed pastille preparation different methods for X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Lima, Raquel Franco de Souza; Melo Junior, Germano; Sa, Jaziel Martins

    1997-01-01

    This work relates the comparison between the results obtained with the two different methods of preparing pressed pastilles from the crushed sample. In this study, the reproductivity is evaluated, aiming to define the method that furnishes a better analytic precision. These analyses were realized with a X-ray fluorescence spectrometer at the Geology Department of the Federal University of Rio Grande do Norte

  12. X-ray fluorescence activities at Saha Institute of Nuclear Physics, India

    Indian Academy of Sciences (India)

    X-ray fluorescence activities at Saha Institute of Nuclear Physics are pursued around three facilities that we have in our division: (i) a Kevex 60 W X-ray generator, (ii) a curved crystal spectrometer (Spectroscan VY) and (iii) 109Cd and 241Am radioactive sources. With the Kevex X-ray generator, using an XYZ geometry, ...

  13. Some aspects of detectors and electronics for x-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Goulding, F.S.

    1976-08-01

    Some of the less recognized and potentially important parameters of the electronics and detectors used in X-ray fluorescence spectrometers are discussed. Detector factors include window (dead-layer) effects, time-dependent background and excess background. Noise parameters of field-effect transistors and time-variant pulse shaping are also discussed

  14. Organising for innovation in regional innovation systems

    DEFF Research Database (Denmark)

    Brink, Tove

    2017-01-01

    The research in this paper reveals how organising the innovation ecosystem can enable the achievement of the aim for innovation and competiveness. The research was conducted from June 2014 to May 2015 using a qualitative deductive approach among operation & maintenance (O&M) actors in offshore wind...... and educational training. A contribution is made to application of the triple helix notion to enable innovation in offshore wind ecosystems....

  15. Open Innovation Ecosystem: Towards Collaborative Innovation

    OpenAIRE

    Böhmer, Annette Isabel; Lindemann, Udo

    2015-01-01

    Innovation is a precondition for the success of companies in today’s markets to differentiate from their competitors. Particularly disruptive innovations are addressed in numerous research contributions, product contests and advertisements. They carry a high risk of failure and often require a high investment in research and development. (Watty, 2013) Corporate groups are often very successful in specialized market segments and with incremental innovations adapted to the needs ...

  16. Fluorescence live cell imaging.

    Science.gov (United States)

    Ettinger, Andreas; Wittmann, Torsten

    2014-01-01

    Fluorescence microscopy of live cells has become an integral part of modern cell biology. Fluorescent protein (FP) tags, live cell dyes, and other methods to fluorescently label proteins of interest provide a range of tools to investigate virtually any cellular process under the microscope. The two main experimental challenges in collecting meaningful live cell microscopy data are to minimize photodamage while retaining a useful signal-to-noise ratio and to provide a suitable environment for cells or tissues to replicate physiological cell dynamics. This chapter aims to give a general overview on microscope design choices critical for fluorescence live cell imaging that apply to most fluorescence microscopy modalities and on environmental control with a focus on mammalian tissue culture cells. In addition, we provide guidance on how to design and evaluate FP constructs by spinning disk confocal microscopy. © 2014 Elsevier Inc. All rights reserved.

  17. Past, present and future roles of the x-ray fluorescence method for materials characterization

    International Nuclear Information System (INIS)

    Jenkins, R.

    1988-01-01

    The use of X-ray methods for materials characterisation include Wavelength and Energy Dispersive Spectrometry, Powder and Single Crystal Diffractometry, plus various types of absorptionmetry. Over the recent years X-ray fluorescence spectrometry has become one of the most valuable methods for the quantitative and qualitative analysis of materials. In particular, the speed, accuracy and versatility of X-ray fluorescence are the most important features amoung the many which have made it the method of choice in over 15 000 laboratories all over the world. Included within the category of speciality spectrometers are Total Reflection Spectrometers (TRXRF), Synchrotron Source Spectrometers (SSXRF), and Proton induced X-ray Emission (PIXE). One thing that each of these three special systems have in common is a very high sensitivity and ability to work with extremely low concentrations and/or small specimens

  18. Measurement of K fluorescence yields in actinide elements

    International Nuclear Information System (INIS)

    Ahmad, I.; Sjoblom, R.K.

    1976-01-01

    The K fluorescence yields (ω/sub K/) for several actinide elements have been determined from the K Auger electron and K x-ray intensities. The electron spectra were measured with a cooled Si(Li) spectrometer and the K x-ray intensities were measured with a Ge(Li) diode. From our present measurements the following values of K fluorescence yield have been obtained: Np, 97.1 +- 0.5 percent; Pu, 97.3 +- 0.5 percent; Cm, 97.2 +- 0.7 percent; Cf, 97.2 +- 0.5 percent; and Es, 97.1 +- 0.5 percent. These numbers indicate that the K fluorescence yield in the Z = 93 to Z = 99 region remains constant within the experimental error

  19. Innovation Types and Talent Management for Innovation

    Directory of Open Access Journals (Sweden)

    Juan A. Marin-Garcia

    2011-12-01

    Full Text Available Companies need to become innovative and in order to do so, they must learn how to be able to manage the talent of their workforce In this working paper we have reviewed the literature concerning the concept of innovation as a key for the challenge for change in companies to establish a synthesis and a classification of the types of innovation required. We propose a number of competencies needed by the different staff members (support, technicians, managers, etc as well, so that they can succeed in being innovative in different ways.

  20. Polychromatic excitation improves detection limits in total reflection X-ray fluorescence analysis compared with monochromatic excitation.

    Science.gov (United States)

    Kunimura, Shinsuke; Kawai, Jun

    2010-08-01

    Detection limits obtained by a portable total reflection X-ray fluorescence (TXRF) spectrometer with or without a monochromator are compared. A 1 W X-ray tube (tube voltage: 20 kV) is used in this spectrometer. Polychromatic excitation improves the detection limits in TXRF analysis with the low power X-ray tube compared with monochromatic excitation. A detection limit of 26 pg is achieved for Co when using the weak polychromatic X-rays.

  1. Innovative fluorescence detection technique for metals in cestode ...

    African Journals Online (AJOL)

    Recent work in the field of parasitology has drawn attention to the application of parasites as pollution-accumulation indicators, particularly cestodes. A discrepancy in metal concentrations within cestode posterior and anterior tissue has led researchers to attribute this phenomenon to metals binding to the shells of their ...

  2. Innovation and collective entrepreneurship

    DEFF Research Database (Denmark)

    Spear, Roger

    2012-01-01

    This paper aims to examine different forms of innovation including social innovation, and why innovation and social innovation have become important themes in public policy – in a context of the increasing and diverse demands on welfare regimes, and in an era of constrained budgets. It will review......, including the role of the institutional and policy framework. It will set this analysis within the context of public policy, demonstrating the role of public policy in enabling such innovations in the social and solidarity economy....... different perspectives on innovation and social innovation and the dynamic interaction through collective entrepreneurship in the the social and solidarity economy; bringing out process and outcome dimensions of innovation. And it will develop an understanding of the drivers and barriers to innovation...

  3. Containers, facilitators, innovators?

    DEFF Research Database (Denmark)

    Makkonen, Teemu; Merisalo, Maria; Inkinen, Tommi

    2018-01-01

    : are they containers, facilitators or innovators? This is investigated here through empirical material derived from 27 interviews with top departmental management in three Finnish cities (Helsinki, Espoo and Vantaa). The results show that local city governments (LCGs) consider cities as facilitators of innovation...... without the active role of LCGs as innovators. City employees are innovative – the seeming lack of public sector innovation is actually a result of measurement issues that favour (patentable) technological innovations rather than those more common to LCGs, meaning service and organisational types....... Therefore, LCGs can be seen as highly innovative organisations. There are, however, barriers to innovation in the public sector, such as the cost of innovation activity, the lack of incentives for it, and working culture that does not support it. Lastly, the results show that LCGs have not really fully...

  4. Hybrid plasmon photonic crystal resonance grating for integrated spectrometer biosensor.

    Science.gov (United States)

    Guo, Hong; Guo, Junpeng

    2015-01-15

    Using nanofabricated hybrid metal-dielectric nanohole array photonic crystal gratings, a hybrid plasmonic optical resonance spectrometer biosensor is demonstrated. The new spectrometer sensor technique measures plasmonic optical resonance from the first-order diffraction rather than via the traditional method of measuring optical resonance from transmission. The resonance spectra measured with the new spectrometer technique are compared with the spectra measured using a commercial optical spectrometer. It is shown that the new optical resonance spectrometer can be used to measure plasmonic optical resonance that otherwise cannot be measured with a regular optical spectrometer.

  5. Motor oil classification based on time-resolved fluorescence.

    Science.gov (United States)

    Mu, Taotao; Chen, Siying; Zhang, Yinchao; Guo, Pan; Chen, He; Meng, Fandong

    2014-01-01

    A time-resolved fluorescence (TRF) technique is presented for classifying motor oils. The system is constructed with a third harmonic Nd:YAG laser, a spectrometer, and an intensified charge coupled device (ICCD) camera. Steady-state and time-resolved fluorescence (TRF) measurements are reported for several motor oils. It is found that steady-state fluorescence is insufficient to distinguish the motor oil samples. Then contour diagrams of TRF intensities (CDTRFIs) are acquired to serve as unique fingerprints to identify motor oils by using the distinct TRF of motor oils. CDTRFIs are preferable to steady-state fluorescence spectra for classifying different motor oils, making CDTRFIs a particularly choice for the development of fluorescence-based methods for the discrimination and characterization of motor oils. The two-dimensional fluorescence contour diagrams contain more information, not only the changing shapes of the LIF spectra but also the relative intensity. The results indicate that motor oils can be differentiated based on the new proposed method, which provides reliable methods for analyzing and classifying motor oils.

  6. Fluorescence intensity dependence on the propagation plane inclination

    International Nuclear Information System (INIS)

    Fernandez, J.E.; Rubio, Marcelo; Sanchez, H. J.

    1987-01-01

    An experimental confirmation of the fluorescence intensity behaviour with the inclination of the propagation plane (α angle) was carried out. A special angular sample-holder was developed and set up on our X-ray spectrometer. This sample-holder allows different positions of irradiation of the sample modifying the α angle until the maximum angle (α Μ ) is reached in the limit situation. In this work, this maximum angle was 86 deg and the incidence and take off angles were both 45 deg. The sample-holder and the collimation system were carefully lined up. The fluorescent spectra of three National Bureau of Standards (NBS) standard samples were taken for sixteen different α angle positions. The theoretical scheme for both enhanced fluorescent lines and nonenhanced fluorescent lines was confirmed, i.e. the invariance of the primary intensity with the α angle and the decline of the enhanced fluorescence intensities under the same conditions. This experimental confirmation agrees with theoretical prediction: the vanishing of the secondary fluorescence in the extreme case α = π/2. (Author) [es

  7. Purchasing and Innovation

    DEFF Research Database (Denmark)

    Hanghøj, Astrid; Mols, Niels Peter

    2015-01-01

    show that integrative, relational, innovative,and intelligence capabilities are positively related to innovation. However, relational capabilities are not found to have significant effect on purchasings contribution to supply and practice innovation, i.e. new markets, new suppliers, and new purchasing...... practices. The relationship between intelligence capabilities and purchasings contribution to product and production innovations depends on the level of innovation capabilities.......In this paper we develop a number of hypotheses relating four purchasing capabilities to two measures of purchasings contribution to innovation. The hypotheses are tested with data collected through a websurvey completed by 321 purchasing professionals in Danish production companies. Our results...

  8. Elpasolite Planetary Ice and Composition Spectrometer (EPICS): A Low-Resource Combined Gamma-Ray and Neutron Spectrometer for Planetary Science

    Science.gov (United States)

    Stonehill, L. C.; Coupland, D. D. S.; Dallmann, N. A.; Feldman, W. C.; Mesick, K.; Nowicki, S.; Storms, S.

    2017-12-01

    The Elpasolite Planetary Ice and Composition Spectrometer (EPICS) is an innovative, low-resource gamma-ray and neutron spectrometer for planetary science missions, enabled by new scintillator and photodetector technologies. Neutrons and gamma rays are produced by cosmic ray interactions with planetary bodies and their subsequent interactions with the near-surface materials produce distinctive energy spectra. Measuring these spectra reveals details of the planetary near-surface composition that are not accessible through any other phenomenology. EPICS will be the first planetary science instrument to fully integrate the neutron and gamma-ray spectrometers. This integration is enabled by the elpasolite family of scintillators that offer gamma-ray spectroscopy energy resolutions as good as 3% FWHM at 662 keV, thermal neutron sensitivity, and the ability to distinguish gamma-ray and neutron signals via pulse shape differences. This new detection technology will significantly reduce size, weight, and power (SWaP) while providing similar neutron performance and improved gamma energy resolution compared to previous scintillator instruments, and the ability to monitor the cosmic-ray source term. EPICS will detect scintillation light with silicon photomultipliers rather than traditional photomultiplier tubes, offering dramatic additional SWaP reduction. EPICS is under development with Los Alamos National Laboratory internal research and development funding. Here we report on the EPICS design, provide an update on the current status of the EPICS development, and discuss the expected sensitivity and performance of EPICS in several potential missions to airless bodies.

  9. Triple-axis spectrometer DruechaL

    International Nuclear Information System (INIS)

    Buehrer, W.; Keller, P.

    1996-01-01

    DruechaL is a triple-axis spectrometer located at a cold guide. The characteristics of guide and instrument allow the use of a broad spectral range of neutrons. The resolution in momentum and energy transfer can be tuned to match the experimental requirements by using either collimators or focusing systems (monochromator, antitrumpet, analyser). (author) figs., tabs., refs

  10. Neutron spectrometer using NE218 liquid scintillator

    International Nuclear Information System (INIS)

    Dance, J.B.; Francois, P.E.

    1976-01-01

    A neutron spectrometer has been constructed using NE218 liquid scintillator. Discrimination against electron-gamma events was obtained usng a charge-comparison pulse shape discrimination system. The resolution obtained was about 0.25 MeV F.W.H.M. at 2.0 MeV

  11. L G Smith's RF mass spectrometer

    International Nuclear Information System (INIS)

    Koets, E.

    1981-01-01

    From 1948 on Lincoln G Smith developed mass spectrometers based on time and frequency measurements. With his last machine he obtained an accuracy of the order of 1 to 10 9 . After his untimely death in 1972 his unique instrument was moved to Delft, where its development is carried on. (author)

  12. Triple-axis spectrometer DruechaL

    Energy Technology Data Exchange (ETDEWEB)

    Buehrer, W.; Keller, P. [Lab. for Neutron Scattering ETH Zurich, Zurich (Switzerland) and Paul Scherrer Institute, Villigen (Switzerland)

    1996-11-01

    DruechaL is a triple-axis spectrometer located at a cold guide. The characteristics of guide and instrument allow the use of a broad spectral range of neutrons. The resolution in momentum and energy transfer can be tuned to match the experimental requirements by using either collimators or focusing systems (monochromator, antitrumpet, analyser). (author) figs., tabs., refs.

  13. Advanced Laboratory NMR Spectrometer with Applications.

    Science.gov (United States)

    Biscegli, Clovis; And Others

    1982-01-01

    A description is given of an inexpensive nuclear magnetic resonance (NMR) spectrometer suitable for use in advanced laboratory courses. Applications to the nondestructive analysis of the oil content in corn seeds and in monitoring the crystallization of polymers are presented. (SK)

  14. A 'tiny-orange' spectrometer for electrons

    International Nuclear Information System (INIS)

    Silva, N.C. da.

    1990-01-01

    An tiny-orange electron spectrometer was designed and constructed using flat permanent magnets and a surface barrier detector. The transmission functions of different system configurations were determined for energies in the 200-1100 KeV range. A mathematical model for the system was developed. (L.C.J.A.)

  15. Imaging mass spectrometer with mass tags

    Science.gov (United States)

    Felton, James S.; Wu, Kuang Jen; Knize, Mark G.; Kulp, Kristen S.; Gray, Joe W.

    2010-06-01

    A method of analyzing biological material by exposing the biological material to a recognition element, that is coupled to a mass tag element, directing an ion beam of a mass spectrometer to the biological material, interrogating at least one region of interest area from the biological material and producing data, and distributing the data in plots.

  16. Design of radial neutron spectrometer for ITER

    International Nuclear Information System (INIS)

    Nishitani, Takeo; Kasai, Satoshi; Iguchi, Tetsuo; Ebisawa, Katsuyuki; Kita, Yoshio.

    1996-09-01

    We designed the radial neutron spectrometer using a new type DT neutron spectrometer base on a recoil proton counter-telescope technique aiming ion temperature measurement for ITER. The neutron spectrometer will be installed on the well-collimated neutron beam line. A large-area recoil proton emitter is placed in parallel to the incident neutron beam and a micro-channel collimating plates are inserted between the radiator and the recoil proton detectors away from the neutron beam in order to limit the scattering angle of protons to the proton detectors. Here a very thin polyethylene film and a silicon surface barrier detector are employed as the radiator and proton detector, respectively. The energy resolution and detection efficiency are estimated to be 2.5% and 1x10 -5 counts/(n/cm 2 ), respectively for DT neutron through Monte Carlo calculations. Five units of the spectrometers will be installed just out side the bio-shield and consist a fun array using penetrations inside the bio-shield and a pre-collimator in the horizontal port. The life time of the proton detectors is estimated to be about one year in the Basic Performance Phase of ITER by neutron transport calculations using MCNP Monte Carlo code. The necessary R and D items and the design work were identified. (author)

  17. Calibration method for ion mobility spectrometer

    International Nuclear Information System (INIS)

    Vasiliev, Valery

    2011-01-01

    The new method for the calibration of the ion mobility spectrometer has been developed. This article describes the working principle, advantages and disadvantages of the calibration method operating in the mode of explosives detection. This method is most suitable for use in portable detectors, due to the small weight, small size parameters and low power consumption.

  18. A superheterodyne spectrometer for electronic paramagnetic. Resonance

    International Nuclear Information System (INIS)

    Laffon, J.L.

    1963-12-01

    After a few generalities about electron paramagnetic resonance, a consideration of different experimental techniques authorises the choice of a particular type of apparatus. An EPR superheterodyne spectrometer built in the laboratory and having a novel circuit is described in detail. With this apparatus, many experimental results have been obtained and some of these are described as example. (author) [fr

  19. A procedure for the improvement in the determination of a TXRF spectrometer sensitivity curve

    International Nuclear Information System (INIS)

    Bennun, Leonardo; Sanhueza, Vilma

    2010-01-01

    A simple procedure is proposed to determine the total reflection X-ray fluorescence (TXRF) spectrometer sensitivity curve; this procedure provides better accuracy and exactitude than the standard established method. It uses individual pure substances instead of the use of vendor-certified values of reference calibration standards, which are expensive and lack any method to check their quality. This method avoids problems like uncertainties in the determination of the sensitivity curve according to different standards. It also avoids the need for validation studies between different techniques, in order to assure the quality of their TXRF results. (author)

  20. A procedure for the improvement in the determination of a TXRF spectrometer sensitivity curve.

    Science.gov (United States)

    Bennun, Leonardo; Sanhueza, Vilma

    2010-01-01

    A simple procedure is proposed to determine the total reflection X-ray fluorescence (TXRF) spectrometer sensitivity curve; this procedure provides better accuracy and exactitude than the standard established method. It uses individual pure substances instead of the use of vendor-certified values of reference calibration standards, which are expensive and lack any method to check their quality. This method avoids problems like uncertainties in the determination of the sensitivity curve according to different standards. It also avoids the need for validation studies between different techniques, in order to assure the quality of their TXRF results.

  1. Triggering system innovation in agricultural innovation systems

    NARCIS (Netherlands)

    Turner, James A.; Williams, Tracy; Nicholas, Graeme; Foote, Jeff; Rijswijk, Kelly; Barnard, Tim; Beechener, Sam; Horita, Akiko

    2017-01-01

    This article describes a process for stimulating engagement among change agents to develop a shared understanding of systemic problems in the agricultural innovation system (AIS), challenge prevalent institutional logics and identify actions they might undertake to stimulate system innovation.

  2. When innovative instructional designs are too innovative

    DEFF Research Database (Denmark)

    Kjærgaard, Thomas; Wahl, Christian

    2015-01-01

    This paper presents a study of what happens when innovation of an instructional design is too innovative. The study investigates an implementation process of a new instructional design in nursing education. The new instructional design should be a step away for a functionalist approach to learning...

  3. [Effect of quantum dots CdSe/ZnS's concentration on its fluorescence].

    Science.gov (United States)

    Jin, Min; Huang, Yu-hua; Luo, Ji-xiang

    2015-02-01

    The authors measured the absorption and the fluorescence spectra of the quantum dots CdSe/ZnS with 4 nm in size at different concentration with the use of the UV-Vis absorption spectroscopy and fluorescence spectrometer. The effect of quantum dots CdSe/ZnS's concentration on its fluorescence was especially studied and its physical mechanism was analyzed. It was observed that the optimal concentration of the quantum dots CdSe/ZnS for fluorescence is 2 micromole x L(-1). When the quantum dot's concentration is over 2 micromol x L(-1), the fluorescence is decreased with the increase in the concentration. While the quantum dot's concentration is less than 2 micromol x L(-1), the fluorescence is decreased with the decrease in the concentration. There are two main reasons: (1) fluorescence quenching and 2) the competition between absorption and fluorescence. When the quantum dot's concentration is over 2 micromol x L(-1), the distance between quantum dots is so close that the fluorescence quenching is induced. The closer the distance between quantum dots is, the more serious the fluorescence quenching is induced. Also, in this case, the absorption is so large that some of the quantum dots can not be excited because the incident light can not pass through the whole sample. As a result, the fluorescence is decreased with the increase in the quantum dot's concentration. As the quantum dot's concentration is below 2 micromol x L(-1), the distance between quantum dots is far enough that no more fluorescence quenching is induced. In this case, the fluorescence is determined by the particle number per unit volume. More particle number per unit volume produces more fluorescence. Therefore, the fluorescence is decreased with the decrease in the quantum dot's concentration.

  4. Highly thermostable fluorescent proteins

    Science.gov (United States)

    Bradbury, Andrew M [Santa Fe, NM; Waldo, Geoffrey S [Santa Fe, NM; Kiss, Csaba [Los Alamos, NM

    2011-03-22

    Thermostable fluorescent proteins (TSFPs), methods for generating these and other stability-enhanced proteins, polynucleotides encoding such proteins, and assays and method for using the TSFPs and TSFP-encoding nucleic acid molecules are provided. The TSFPs of the invention show extremely enhanced levels of stability and thermotolerance. In one case, for example, a TSFP of the invention is so stable it can be heated to 99.degree. C. for short periods of time without denaturing, and retains 85% of its fluorescence when heated to 80.degree. C. for several minutes. The invention also provides a method for generating stability-enhanced variants of a protein, including but not limited to fluorescent proteins.

  5. Innovating innovation Policy. Rethinking green innovation policy in evolutionary perspective

    NARCIS (Netherlands)

    Arentsen, Maarten J.; Dinica, V.; Marquart, N.E.

    1999-01-01

    Advanced environmental standards such as sustainability require substantial improvements in the environmental performances of present technologies. Governments are faced with the challenge to design green innovation policies able to support producers and users of technologies to comply with such

  6. TR and fluorescence study of organic nanostructures

    International Nuclear Information System (INIS)

    Zheludeva, S.; Novikova, N.; Myagkov, I.; Yurieva, E.

    2000-01-01

    The development of several x-ray scattering techniques based on total external fluorescence study and x-ray standing wave method is presented and used for characterization of organic nano-structures on the base of Langmuir-Blodgett films of fatty acid salts and phospholipids. Spectral selectivity of data obtained permits to detect alien interfacial layers and ions in organic structures, to get information about inter-diffusion at the interfaces, about ion permeation through organic bilayers - models of bio-membranes. The perspectives of investigation of protein - lipid bilayers on liquid surface by above mentioned techniques at SR source are discussed. Such study may allow to explore conformation structure and biological functions of membrane proteins and channel forming molecules in their native environment. The facilities of X-ray spectrometer designed and constructed for this purpose are presented. (author)

  7. Multi-element analysis of pyrite ores using polarized energy-dispersive X-ray fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ustuendag, Zafer [Department of Chemistry, Faculty of Science, Ankara University, Ankara (Turkey)]. E-mail: zustun@science.ankara.edu.tr; Ustuendag, Ilknur [Department of Physics Engineering, Faculty of Engineering, Hacettepe University, Ankara (Turkey); Kagan Kadioglu, Yusuf [Department of Geological Engineering, Faculty of Engineering, Ankara University, Ankara (Turkey)

    2007-07-15

    X-ray fluorescence (XRF) spectrometry is used worldwide in geological material analysis. This study, applies polarized energy-dispersive X-ray fluorescence (PEDXRF) Spectrometer and compares in the samples of Rize-Cayeli and Mardin pyrite ores. The samples of pyrite ore were collected from the Rize and Mardin in Turkey. The prepared samples were analyzed using a PEDXRF spectrometer. The result of the analysis shows the presence of many elements including rare-earth elements (from Na to Th). The accuracy and precision of the technique for chemical analysis is demonstrated by analyzing USGS standards, GEOL, GBW 7109 and GBW-7309 sediment.

  8. Pathfinder Innovation Projects

    Science.gov (United States)

    The Pathfinder program supports high-risk, high-reward research ideas with funding and staff time. The goal is to feed a culture of innovation in the Agency and integrate innovative ideas in EPA research programs.

  9. Innovation and STEM Schools

    Science.gov (United States)

    Roberts, Julia Link

    2015-01-01

    How do schools with a focus on science, technology, engineering, and mathematics (STEM) fit in with state goals to increase innovation and to boost the economy? This article briefly discusses how educators can encourage creativity and innovation.

  10. Detecting Social Innovation agency

    DEFF Research Database (Denmark)

    Pel, Bonno; Dorland, Jens; Wittmayer, Julia

    2017-01-01

    Considering that it is important for the social innovation research field to confront its methodological challenges, this contribution addresses the challenge of choosing appropriate units of analysis. In processes of transformative social innovation, the agency is distributed and therefore...

  11. Diversity and Innovation

    DEFF Research Database (Denmark)

    Østergaard, Christian Richter; Timmermans, Bram; Kristinsson, Kári

    2007-01-01

    Denne metoderapport udgør og beskriver den kvantitative analyse, som er grundlaget for kapitel 6 og appendiks 2 i Forsknings- og Innovationsstyrelsens rapport om Innovation og mangfoldighed - Ny viden og erfaringer med medarbejderdreven innovation...

  12. Roadmap for Inclusive Innovation

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — The Roadmap for Inclusive Innovation data set shares the status of action items under the Roadmap for Inclusive Innovation. Each action or project has been assigned...

  13. In search of Innovation

    DEFF Research Database (Denmark)

    Lex, Simon Westergaard

    2016-01-01

    This essay explores innovation as a socially and culturally embedded practice, coming to life in correlation between structural organizational conventions and entrepreneurial performances. With an empirical departure, it describes a rational understanding of creation, and it identifies innovation...

  14. Innovative Work Behavior

    DEFF Research Database (Denmark)

    Pihl-Thingvad, Signe; Klausen, Kurt Klaudi

    work behaviour of the employees in a particular empirical setting. Innovative work behaviour has become an important concept in the literature on innovation. Theories on managing change and innovation in public service organizations would suggest that managers have several possibilities when ensuring...... the behaviour of both managers and employees. In order to ensure the implementation of innovation, public managers must pay close attention to the behaviour of the employees. This paper focuses on how and to which extend innovation is implemented into public service organizations, by examining the innovative...... the implementation of innovation. There is, however, still a gap (both empirical and theoretical) in the literature on how managers can contribute to and strengthen the employees’ innovative work behaviour in public service organizations. Therefore, we focus on the following research questions. Which management...

  15. Cyclical innovations and production

    OpenAIRE

    Greiner, Alfred

    1994-01-01

    Cyclical innovations and production : a formal model of the firm reflecting Schumpeterian ideas / Alfred Greiner and Horst Hanusch. - In: Innovation in technology, industries, and institutions / ed. by Yuichi Shionoya ... - Ann Arbor : Univ. of Michigan Press, 1994. - S. 157-169

  16. Innovations, status, and networks

    NARCIS (Netherlands)

    P. Wang (Pengfei)

    2016-01-01

    markdownabstractTo obtain and maintain competitive advantage, firms need to implement appropriate innovation strategies (i.e. exploration or exploitation) and acquire status in external networks. In this dissertation, I investigate how innovation strategy, status, and network structure jointly

  17. Dis-locating innovation

    NARCIS (Netherlands)

    Barba Latta, Iulian I.V.

    2017-01-01

    This dissertation dwells on an experimental approach to the emergence of alternative innovations, interrogated through their spatiotemporal and material conditions. Proceeding from the more recent spate of contributions that grant recognition to innovation processes as a common feature of any

  18. Logistic innovations in transport

    Directory of Open Access Journals (Sweden)

    Mirosław Antonowicz

    2014-03-01

    Full Text Available Introduction: The article discusses the issue of logistic innovations in transport. The essentials of logistic innovations in transport together with some examples of specific innovations are presented. The role of the client's needs in transport innovations is indicated. The most vital postulates affecting the innovativeness of shipping companies and derived from the author's experience as well as scholarly publications, are time, safety, reliability as well as comprehensiveness of service offer. Following the analysis of the issue, and on the grounds of Kaizen's and Lean's method, the concept of continuous innovations is suggested as very useful for the development of transport. The potential of clusters as the source of logistic innovations in transport is emphasised. Methods: The discussion of the issue was preceded by the author's analysis of written sources on innovativeness, the evaluation of ratings of innovativeness as well as the analysis of rewarded innovative solutions in transport subsequent to the businesses participation in the programme of innovative solutions in transport. The role of innovation practical business operations is argued following the analysis of some strategic documents such as: 2011 White Paper and the Strategy for the Development of Transport by 2020 adopted by the Polish government in 2013. Aim: The aim of the article is to present the role and significance of the issue of logistic innovations in transport and to cite instances of practical solutions implemented by shipping companies, the solutions which resulted in measurable effects. Following the author's observation of the instances of innovative solutions as well as his analysis of the ratings of innovativeness, the article aims to present the conclusions as for the specific kinds of activities which are indispensable to foster innovativeness in transport. Conclusions: The conclusions derived from the author's analyses and observations show that logistic

  19. SuperSpec: A Revolutionary New Spectrometer for Submillimeter Astronomy

    Data.gov (United States)

    National Aeronautics and Space Administration — SuperSpec is a new spectrometer for submm astronomy. SuperSpec stands out from other submm spectrometers in that the detectors are coupled to a series of resonant...

  20. Entrepreneurship and Innovation Policy

    OpenAIRE

    Erik Stam

    2008-01-01

    What is meant by entrepreneurship, innovation and economic growth is often not clear or very idiosyncratic. This paper starts with a discussion of the nature of entrepreneurship and its relation to innovation. The second section provides an overview of theory and empirical research on the relation between entrepreneurship, innovation and economic growth. The paper continues with a study on entrepreneurship and innovation in the Netherlands in an international and historical perspective. After...

  1. Institutionel innovation i professionsfeltet

    OpenAIRE

    Bretlau, Lars

    2008-01-01

    The title of this master dissertation is: ”Institutional innovation in Bachelor Degrees of profes-sion – potentials and barriers”. The question examined in the dissertation are: why innovation is becoming increasingly desi-rable for professions and which institutional potentials and barriers can be expected as a con-sequence of implementing institutional innovation in the Danish professional education sector? These questions aim to examine how challenges of innovation can be openly and system...

  2. Strategy of technical innovation

    International Nuclear Information System (INIS)

    Lee, Ga Jong

    1990-12-01

    This book deals with policy of scientific technique and technical innovation such as research for development and types of technical innovation, historical development and process of technical innovation, economic growth, technology change and investment for research and development, structure and form of technical transfer with the meaning process, from, structure and theory, economic growth and investment of research and development with experiential analysis and case study on strategy of technical innovation in electron and fine chemical industry.

  3. 16 tales of innovation

    DEFF Research Database (Denmark)

    16 Tales of Innovation are told by 16 leaders, who have completed the LAICS executive master program, a collaboration between Aarhus University and Copenhagen Business School. The book is based on their Master theses and illustrates how they have experimented with different innovation tools, models...... and innovation theories within their own organization. Here they share their unique insights into the processes, methods and the impact of their academic work with innovation in practice....

  4. Innovating for sustainability

    DEFF Research Database (Denmark)

    The theme of the articles is innovating for sustainability. Empirically the articles shows how enterprises makes environmental innovations related to their processes and products within the organic dairy industry, the fish processing industry and the car industry.......The theme of the articles is innovating for sustainability. Empirically the articles shows how enterprises makes environmental innovations related to their processes and products within the organic dairy industry, the fish processing industry and the car industry....

  5. The Pharmakon of Innovation

    DEFF Research Database (Denmark)

    Johnsen, Christian Garmann

    , the concept of management is attributed a curious dual function, as being, on the one hand, the ‘toxic’ that can ‘kill’ innovation, and, on the other hand, ‘cure’ that will make the organization innovative. Informed by Derrida’s reflection upon the dual meaning of Plato’s concept of pharmakon, as being both...... weather management is the cure or the poison for innovation. We will therefore show how management is the pharmakon of innovation....

  6. Measuring Manufacturing Innovativeness

    DEFF Research Database (Denmark)

    Blichfeldt, Henrik; Knudsen, Mette Præst

    2017-01-01

    Globalization and customization increases the pressure on manufacturing companies, and the ability to provide innovativeness is a potential source of competitive advantage. This paper positions the manufacturing entity in the innovation process, and investigates the relation between innovation vers...... technology and organizational concepts. Based on Danish survey data from the European Manufacturing Survey (EMS-2015) this paper finds that there is a relation between innovative companies, and their level of technology and use of organizational concepts. Technology and organizational concepts act...

  7. Reviews in fluorescence 2007

    CERN Document Server

    Lakowicz, Joseph R; Geddes, Chris D

    2009-01-01

    This fourth volume in the Springer series summarizes the year's progress in fluorescence, with authoritative analytical reviews specialized enough for professional researchers, yet also appealing to a wider audience of scientists in related fields.

  8. Introduction to fluorescence

    CERN Document Server

    Jameson, David M

    2014-01-01

    "An essential contribution to educating scientists in the principles of fluorescence. It will also be an important addition to the libraries of practitioners applying the principles of molecular fluorescence."-Ken Jacobson, Kenan Distinguished Professor of Cell Biology and Physiology, University of North Carolina at Chapel Hill"An exquisite compendium of fluorescence and its applications in biochemistry enriched by a very exciting historical perspective. This book will become a standard text for graduate students and other scientists."-Drs. Zygmunt (Karol) Gryczynski and Ignacy Gryczynski, University of North Texas Health Science Center"… truly a masterwork, combining clarity, precision, and good humor. The reader, novice or expert, will be pleased with the text and will not stop reading. It is a formidable account of the fluorescence field, which has impacted the life sciences so considerably in the last 60 years."-Jerson L. Silva, M.D., Ph.D., Professor and Director, National Institute of Science and Tech...

  9. Social Innovation Europe: Country Summary: Poland. Social Innovation in Poland

    OpenAIRE

    Klimczuk, Andrzej

    2015-01-01

    The history of social innovation in country, challenges being addressed by social innovation. the key actors, who is promoting social innovation. A few of the key projects that illustrate social innovation.

  10. The TRIUMF low energy pion spectrometer and channel

    International Nuclear Information System (INIS)

    Sobie, R.J.; Drake, T.E.; Barnett, B.M.; Erdman, K.L.; Gyles, W.; Johnson, R.R.; Roser, H.W.; Tacik, R.; Blackmore, E.W.; Gill, D.R.

    1983-08-01

    A low energy pion spectrometer has been developed for use with the TRIUMF M13 pion channel. The combined channel and spectrometer resolution is presently 1.1 MeV at T = 50 MeV. This is limited by the amount of gas and detector material in the spectrometer in addition to the inherent resolution of the channel. Improvements to both the spectrometer and channel are discussed

  11. Hardware of automation systems of isotope mass spectrometers

    International Nuclear Information System (INIS)

    Manojlov, V.V.; Meleshkin, A.S.; Novikov, L.V.; Kornil'ev, S.O.; Voronin, B.M.

    1997-01-01

    The modernized hardware of isotope mass spectrometers is described. The modern control systems for the mass spectrometers are fulfilled on the basis of IBM/PC AT. Versions of subsystems mass spectrometer control through a standard bus and through a digital-to-analog converter are considered. The characteristics of an electrometric amplifier and interface cards developed for modernized automation systems of the isotope mass spectrometers are presented

  12. Miniature anastigmatic spectrometer design with a concave toroidal mirror.

    Science.gov (United States)

    Dong, Jianing; Chen, He; Zhang, Yinchao; Chen, Siying; Guo, Pan

    2016-03-01

    An advanced optical design for a low-cost and astigmatism-corrected spectrometer with a high resolution is presented. The theory and method of astigmatism correction are determined with the use of a concave toroidal mirror. The performances of a modified spectrometer and a traditional spectrometer are compared, and the analysis is verified. Experimentally, the limiting resolution of our spectrometer is 0.1 nm full width at half-maximum, as measured for 579.1 nm.

  13. Technical innovation and management

    International Nuclear Information System (INIS)

    Yoon, Yang Cheol

    1982-08-01

    This book gives explanations of the conception of technical innovation, development plan in Korea, connection between technology and a growth factor in national income, problem of technical innovation in developing country, analysis on cooperation between a developed country and a developing country, evaluation and strategy of technical development in Korea, technical innovation of industry, management of technical industry, analysis of special condition in Korea.

  14. Business Model Innovation Leadership

    DEFF Research Database (Denmark)

    Lindgren, Peter

    2012-01-01

    When SME´s practice business model (BM) innovation (BMI), leading strategically BMs through the innovation process can be the difference between success and failure to a BM. Business Model Innovation Leadership (BMIL) is however extremely complex to carry out especially to small and medium size...

  15. Revolution of Innovation Management

    DEFF Research Database (Denmark)

    Viardot, Eric

    management such as user innovation, crowd sourcing and crowd funding, as well as social media. In line with the constant globalization of innovation, the first volume of Revolution of Innovation Management offers a variety of international perspectives on these topics with illustrations and analysis coming...

  16. China's Innovation Paradox

    Science.gov (United States)

    Chan, Jeremy

    2015-01-01

    China aims to become an innovation-led nation by 2020, but its leadership is generally sceptical--and oftentimes hostile--to the market forces, open exchange of ideas, and creative destruction that have unlocked innovation in other countries. Instead, Beijing hopes to promote innovation in China through a massive expansion in higher education,…

  17. Bureaucracy and Innovation Revisited

    DEFF Research Database (Denmark)

    Hartmann, Mia Koss; Koss Hartmann, Rasmus

    expectations of epistemic boundaries and these expectations lead to both innovation and innovation hiding, which interact to produce low levels of overt innovation. We make this argument based on three years of full-time in-depth ethnographic field studies in two police units and two military units...

  18. Competition and Innovation Policy

    OpenAIRE

    Philip Lowe

    2008-01-01

    Innovation and competition go hand in hand. Innovative markets are competitive markets and innovative companies succeed in them. In the European Commission, as in competition authorities across the world, our focus is on ensuring that this happens in the most efficient and fair manner.

  19. Innovation, exports and productivity

    NARCIS (Netherlands)

    Cassiman, B.; Golovko, E.; Martinez-Ros, E.

    2010-01-01

    We argue that the positive association found between firm productivity and exports in the literature relates to the firm's innovation decisions. Using a panel of Spanish manufacturing firms we find strong evidence that product innovation - and not process innovation - affects productivity and

  20. Innovate or Die.

    NARCIS (Netherlands)

    Jagersma, P.K.

    2003-01-01

    Concentrates on innovation as an under-exploited path to success in the business community, though reckons becoming innovative is not easy. Suggests innovative companies have a number of common characteristics, which are ten strategies to be implemented to create success, these are listed in full.

  1. Differentially pumped dual linear quadrupole ion trap mass spectrometer

    Science.gov (United States)

    Owen, Benjamin C.; Kenttamaa, Hilkka I.

    2015-10-20

    The present disclosure provides a new tandem mass spectrometer and methods of using the same for analyzing charged particles. The differentially pumped dual linear quadrupole ion trap mass spectrometer of the present disclose includes a combination of two linear quadrupole (LQIT) mass spectrometers with differentially pumped vacuum chambers.

  2. 21 CFR 862.2860 - Mass spectrometer for clinical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Mass spectrometer for clinical use. 862.2860 Section 862.2860 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Instruments § 862.2860 Mass spectrometer for clinical use. (a) Identification. A mass spectrometer for...

  3. A magnetic-lens - mini-orange coincidence spectrometer

    International Nuclear Information System (INIS)

    Bargholtz, C.; Holmberg, L.; Ruus, N.; Tegner, P.E.; Weiss, G.

    1997-04-01

    A coincidence spectrometer consisting of a Gerholm type magnetic lens and a permanent magnet mini-orange spectrometer is described. Electron-electron or electron-positron coincidences may be registered in various angular settings. The spectrometer has been developed mainly to search for anomalous contributions to Bhabha scattering or positrons and is at present used for such studies. 6 refs

  4. Measured properties of an out-of-plane spectrometer

    International Nuclear Information System (INIS)

    Mandeville, J.B.; Cardman, L.S.; Dolfini, S.M.; Kim, W.; Laszewski, R.M.; Papanicolas, C.N.; Williamson, S.E.; Alarcon, R.; Goergen, J.; Martinez, D.; Dow, K.; Farkhondeh, M.M.; Tieger, D.; Zumbro, J.; Epstein, M.; Magaziotis, D.; Bernstein, A.; Bertozzi, W.; Bhushan, V.; Gilad, S.; Holtrop, M.; Jordan, D.; McIlvain, T.; Weinstein, L.; Beck, R.; Boeglin, W.; Offermann, E.A.J.M.

    1994-01-01

    We report the results of measurements of the properties of a prototype out-of-plane magnetic spectrometer (OOPS). This spectrometer is one of four identical modules which, together with a support structure, comprise the OOPS cluster. The performance of the spectrometer was found to closely match its design characteristics. (orig.)

  5. Practical using of TXRF spectrometers with slitless collimators for the trace analysis of targets surfaces

    International Nuclear Information System (INIS)

    Egorov, V.K.; Zuev, A.P.; Kondratiev, O.S.; Egorov, E.V.

    2000-01-01

    TXRF spectrometer with the slitless collimator used for a formation of the x-ray excitating beam (TXRF-SC spectrometer) is a new variety of an instrument been destined for the trace analysis of surfaces by x-ray fluorescence method at the total reflection of the x-ray incident beam. Some theoretical concepts are introduced for a characterization of the x-ray optics been unique to the TXRF-SC spectrometer. The principle design of the TXRF-SC spectrometer used for the trace quantitative analysis of a surface are discussed. Spectra of a secondary x-ray radiation yield for typical targets been collected by using of the TXRF-SC spectrometer and calculation of surface trace elements concentrations are presented. The analytical and operating parameters of the TXRF-SC spectrometer and one characterized by standard optical scheme are compared. The slitless collimator of the x-ray radiation is formed by two quartz polished plates mated together. Lengths of the plates are not equal. The target is placed on the surface of the long quartz plate and produces the continuation of the initial slitless collimator. Target orientation problem vanishes but problem of the surface contact effect appears. The secondary x-ray radiation excitated in a surface of the target is led out across the hole in the long quartz plate. The radiation is registered by a standard Si (Li) semiconductor detector and is collected by a multi-channel analyzer. The fundamental difference of the x-ray optical scheme been unique to TXRF-SC spectrometer from the standard one is the excitation of a studied surface by a flared x-ray beam with angle ΔΘ = 2Θ c , where Θ c is the critical angle of the total reflection. The vital peculiarity of a x-ray slitless collimation is the absence of a radiation monochromatism in output of the collimator. The sensible divergence of the x-ray excitating beam and the availability in it of monochromatic and white radiation alike allow to get in the surface layer of target the

  6. Fluorescence--remission sensoring of skin tumours: preliminary results.

    Science.gov (United States)

    Wollina, Uwe; Nelskamp, Cornelia; Scheibe, Armin; Fassler, Dieter; Schmidt, Wolf-Dieter

    2007-11-01

    Nonmelanoma skin cancer (NMSC) is one of the most common malignancies in men. Objective evaluation by digital dermoscopy, as for pigmented lesions, does not provide sufficient data to discriminate between benign and malignant lesions. Therefore, other techniques have to be developed. Hospitalized patients of an academic teaching hospital were evaluated. Because the simultaneous measurement of fluorescence and remission of skin is impossible, a principle of subsequent measurement of remission and fluorescence had been developed by our group. This was combined with dermoscopic imaging. VIS-NIR remission spectroscopy was performed using the laboratory device TIDAS. Fluorescence spectroscopy was realized using a SKINSKAN. Fluorescence emission was detected by a highly sensitive PMT-detector. Based on this evaluation, we developed an optimized measuring device (FRIS, fluorescence-remission-imaging sensor) combining sensors for fluorescence, remission and digital imaging with a white light ring illumination, a drilled mirror and fibre optics. FRIS consists of an industrial personal computer with a touch screen combining three UV-VIS spectrometer modules and a white light source for remission measurements and referencing. Furthermore, included are a CCD coloured camera module and an LED white light ring-illumination. Fluorescence emission is realized by a UV-LED with a peak wavelength of 370 nm. System control uses Window frames and a specifically developed software Skinrem3.exe . Using this technology, we performed a pilot study in 19 patients with 30 NMSC-suspicious lesions including: actinic keratosis (n=10), basal cell carcinoma (BCC; n=16) and squamous cell carcinoma (SCC; n=4 with two in situ carcinomas). Reproducibility measured or FRIS by relative standard deviation of repeated spectroscopic measurements was 2 AU indicates BCC. To substantiate the diagnostic potency of this technology, further studies are needed. A combination of fluorescence and remission

  7. ACCOUNTING OF THE INNOVATION OPERATIONS

    Directory of Open Access Journals (Sweden)

    S. Kafka

    2017-08-01

    Full Text Available The main points of innovation of enterprises, the requirements for innovation, sources of funding, stages of the life cycle of product innovation, the order of recording transactions of innovative character were researched.

  8. Staging Collaborative Innovation Processes

    DEFF Research Database (Denmark)

    Pedersen, Signe; Clausen, Christian

    Organisations are currently challenged by demands for increased collaborative innovation internally as well as with external and new entities - e.g. across the value chain. The authors seek to develop new approaches to managing collaborative innovative processes in the context of open innovation...... and public private innovation partnerships. Based on a case study of a collaborative design process in a large electronics company the paper points to the key importance of staging and navigation of collaborative innovation process. Staging and navigation is presented as a combined activity: 1) to translate...

  9. Service co-innovation

    DEFF Research Database (Denmark)

    Henten, Anders; Sundbo, Jon; Sundbo, Donna

    This paper examines the factors affecting the innovativeness of service encounters. The assumption is that a considerable share of innovations in service industries is initiated in the service encounters. The theoretical foundation of this paper builds on a combination of research tradition...... of studies of the degree of satisfaction of the users with the services in the service encounters and studies that examine service innovation processes. The paper is based on research conducted in 21 service delivery situations in as many service companies. Drivers of and barriers to encounterbased service...... innovation and a model are presented. The conclusion is that employees are the core factor in connecting customers with the innovating organization....

  10. Innovation policies for tourism

    DEFF Research Database (Denmark)

    Hjalager, Anne-Mette

    2012-01-01

    The nature, extent, and implications of innovation in tourism are increasingly investigated in academic research, but the policies that affect these transformations in the industry and at tourism destinations are not equally well conceptualised theoretically or analysed empirically. The purpose...... of this article is, in an analysis of the literature, to interpret the rationale behind innovation policy, and to explain the persisting challenges related to acquisition of an informed foundation for policies based upon quantitative and qualitative inquiries. Observed in a historical perspective, innovation...... framework of policy instruments for innovation in tourism. New generations of policies instigate a mainstreaming of the innovation agenda in ways that proceed beyond the traditional policy concepts....

  11. Revolution of Innovation Management

    DEFF Research Database (Denmark)

    This edited collection explores how digitalization is changing the management of innovation, and the subsequent implications for the next phases in its development. The authors identify and examine relevant phenomena which are related to the ongoing digital breakthrough in the context of innovation...... management such as user innovation, crowd sourcing and crowd funding, as well as social media. In line with the constant globalization of innovation, the first volume of Revolution of Innovation Management offers a variety of international perspectives on these topics with illustrations and analysis coming...

  12. Revolution of Innovation Management

    DEFF Research Database (Denmark)

    This edited volume explores how the rapid development of business model innovation changes innovation management at an international level. It discusses the next phases in its development, and the impact that this could have on the field. The authors identify and examine recent trends which have...... the potential to disrupt the traditional way of managing innovation, notably in terms of creativity, product development, and process change. In line with the constant globalization of innovation, the second volume of Revolution of Innovation Management offers a variety of international perspective...

  13. Multiple-ion-beam time-of-flight mass spectrometer

    International Nuclear Information System (INIS)

    Rohrbacher, Andreas; Continetti, Robert E.

    2001-01-01

    An innovative approach to increase the throughput of mass spectrometric analyses using a multiple-ion-beam mass spectrometer is described. Two sample spots were applied onto a laser desorption/ionization target and each spot was simultaneously irradiated by a beam of quadrupled Nd:YLF laser radiation (261.75 nm) to produce ions by laser-desorption ionization. Acceleration of the ions in an electric field created parallel ion beams that were focused by two parallel einzel lens systems. After a flight path of 2.34 m, the ions were detected with a microchannel plate-phosphor screen assembly coupled with a charge coupled device camera that showed two resolved ion beams. Time-of-flight mass spectra were also obtained with this detector. Experiments were performed using both metal atom cations (Ti + and Cr + ) produced by laser desorption/ionization and the molecular ions of two different proteins (myoglobin and lysozyme), created by matrix assisted laser desorption/ionization using an excess of nicotinic acid as matrix

  14. Multiple-ion-beam time-of-flight mass spectrometer

    Science.gov (United States)

    Rohrbacher, Andreas; Continetti, Robert E.

    2001-08-01

    An innovative approach to increase the throughput of mass spectrometric analyses using a multiple-ion-beam mass spectrometer is described. Two sample spots were applied onto a laser desorption/ionization target and each spot was simultaneously irradiated by a beam of quadrupled Nd:YLF laser radiation (261.75 nm) to produce ions by laser-desorption ionization. Acceleration of the ions in an electric field created parallel ion beams that were focused by two parallel einzel lens systems. After a flight path of 2.34 m, the ions were detected with a microchannel plate-phosphor screen assembly coupled with a charge coupled device camera that showed two resolved ion beams. Time-of-flight mass spectra were also obtained with this detector. Experiments were performed using both metal atom cations (Ti+ and Cr+) produced by laser desorption/ionization and the molecular ions of two different proteins (myoglobin and lysozyme), created by matrix assisted laser desorption/ionization using an excess of nicotinic acid as matrix.

  15. INNOVATIVE TECHNOLOGY VERIFICATION REPORT XRF ...

    Science.gov (United States)

    The Niton XLt 700 Series (XLt) XRF Services x-ray fluorescence (XRF) analyzer was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation (SITE) Program. The field portion of the demonstration was conducted in January 2005 at the Kennedy Athletic, Recreational and Social Park (KARS) at Kennedy Space Center on Merritt Island, Florida. The demonstration was designed to collect reliable performance and cost data for the XLt analyzer and seven other commercially available XRF instruments for measuring trace elements in soil and sediment. The performance and cost data were evaluated to document the relative performance of each XRF instrument. This innovative technology verification report describes the objectives and the results of that evaluation and serves to verify the performance and cost of the XLt analyzer. Separate reports have been prepared for the other XRF instruments that were evaluated as part of the demonstration. The objectives of the evaluation included determining each XRF instrument’s accuracy, precision, sample throughput, and tendency for matrix effects. To fulfill these objectives, the field demonstration incorporated the analysis of 326 prepared samples of soil and sediment that contained 13 target elements. The prepared samples included blends of environmental samples from nine different sample collection sites as well as spiked samples with certified element concentrations. Accuracy

  16. Circular dichroism spectroscopy of fluorescent proteins

    NARCIS (Netherlands)

    Visser, N.V.; Hink, M.A.; Borst, J.W.; Krogt, van der G.N.M.; Visser, A.J.W.G.

    2002-01-01

    Circular dichroism (CD) spectra have been obtained from several variants of green fluorescent protein: blue fluorescent protein (BFP), enhanced cyan fluorescent protein (CFP), enhanced green fluorescent protein (GFP), enhanced yellow fluorescent protein (YFP), all from Aequorea victoria, and the red

  17. The SeaQuest Spectrometer at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Aidala, C.A.; et al.

    2017-06-29

    The SeaQuest spectrometer at Fermilab was designed to detect oppositely-charged pairs of muons (dimuons) produced by interactions between a 120 GeV proton beam and liquid hydrogen, liquid deuterium and solid nuclear targets. The primary physics program uses the Drell-Yan process to probe antiquark distributions in the target nucleon. The spectrometer consists of a target system, two dipole magnets and four detector stations. The upstream magnet is a closed-aperture solid iron magnet which also serves as the beam dump, while the second magnet is an open aperture magnet. Each of the detector stations consists of scintillator hodoscopes and a high-resolution tracking device. The FPGA-based trigger compares the hodoscope signals to a set of pre-programmed roads to determine if the event contains oppositely-signed, high-mass muon pairs.

  18. Portable gas chromatograph-mass spectrometer

    Science.gov (United States)

    Andresen, B.D.; Eckels, J.D.; Kimmons, J.F.; Myers, D.W.

    1996-06-11

    A gas chromatograph-mass spectrometer (GC-MS) is described for use as a field portable organic chemical analysis instrument. The GC-MS is designed to be contained in a standard size suitcase, weighs less than 70 pounds, and requires less than 600 watts of electrical power at peak power (all systems on). The GC-MS includes: a conduction heated, forced air cooled small bore capillary gas chromatograph, a small injector assembly, a self-contained ion/sorption pump vacuum system, a hydrogen supply, a dual computer system used to control the hardware and acquire spectrum data, and operational software used to control the pumping system and the gas chromatograph. This instrument incorporates a modified commercial quadrupole mass spectrometer to achieve the instrument sensitivity and mass resolution characteristic of laboratory bench top units. 4 figs.

  19. Neutron spectrometer for improved SNM search.

    Energy Technology Data Exchange (ETDEWEB)

    Vance, Andrew L.; Aigeldinger, Georg

    2007-03-01

    With the exception of large laboratory devices with very low sensitivities, a neutron spectrometer have not been built for fission neutrons such as those emitted by special nuclear materials (SNM). The goal of this work was to use a technique known as Capture Gated Neutron Spectrometry to develop a solid-state device with this functionality. This required modifications to trans-stilbene, a known solid-state scintillator. To provide a neutron capture signal we added lithium to this material. This unique triggering signal allowed identification of neutrons that lose all of their energy in the detector, eliminating uncertainties that arise due to partial energy depositions. We successfully implemented a capture gated neutron spectrometer and were able to distinguish an SNM like fission spectrum from a spectrum stemming from a benign neutron source.

  20. PAC Spectrometer for Condensed Matter Investigation

    CERN Document Server

    Brudanin, V B; Kochetov, O I; Korolev, N A; Milanov, M; Ostrovsky, I V; Pavlov, V N; Salamatin, A V; Timkin, V V; Velichkov, A I; Fomicheva, L N; Tsvyaschenko, A V; Akselrod, Z Z

    2005-01-01

    A four-detector spectrometer of perturbed angular $\\gamma \\gamma $ correlations is developed for investigation of hyperfine interactions in condensed matter. It allows measurements with practically any types of detectors. A unique circuit design involving a specially developed Master PAC unit combined with a computer allows a substantially higher efficiency, reduced setup time and simpler operation in comparison with traditional PAC spectrometers. A cryostat and a high-temperature oven allow measurements in the temperature range from 120 to 1300 K. An encased electromagnet makes it possible to generate a magnetic field up to 2 T on a sample. The measurement system includes a press with a specially designed high-pressure chamber allowing on-line PAC measurements in samples under pressure up to 60 GPa.