WorldWideScience

Sample records for flow magnetic resonance

  1. Increased cerebral blood flow in preeclampsia with magnetic resonance imaging

    NARCIS (Netherlands)

    Zeeman, GG; Hatab, MR; Twickler, DM

    2004-01-01

    Objective: The purpose of this study was to compare third trimester and nonpregnant cerebral blood flow of women with preeclampsia to normotensive control subjects with the use of magnetic resonance imaging techniques. Study design: Nine normotensive pregnant women and 12 untreated women with preecl

  2. Magnetic resonance imaging of cerebrospinal fluid flow in pediatrics

    Energy Technology Data Exchange (ETDEWEB)

    Heroux, R. [Children' s Hospital of Eastern Ontario, Magnetic Resonance Imaging Dept., Ottawa, Ontario (Canada)

    2000-06-30

    Magnetic Resonance Imaging of flowing protons in cerebrospinal fluid is useful for demonstrating areas of obstruction or stenosis of the ventricular system causing hydrocephalus. This is used in pediatric patients to assess the circulation of the cerebrospinal fluid. This article discusses two studies. In the first, the cerebrospinal fluid flow study helped the neurosurgeon assess the patency after a third ventriculocisternostomy. The second study evaluated the cerebrospinal fluid flowing through the foramen magnum in a patient with cerebellar tonsilar descent (Chiari malformation) and a syringomyelia. Different techniques to evaluate the flow studies are also discussed. (author)

  3. Quantitative velocity distributions via nuclear magnetic resonance flow metering

    Science.gov (United States)

    O'Neill, Keelan T.; Fridjonsson, Einar O.; Stanwix, Paul L.; Johns, Michael L.

    2016-08-01

    We demonstrate the use of Tikhonov regularisation as a data inversion technique to determine the velocity distributions of flowing liquid streams. Regularisation is applied to the signal produced by a nuclear magnetic resonance (NMR) flow measurement system consisting of a pre-polarising permanent magnet located upstream of an Earth's magnetic field NMR detection coil. A simple free induction decay (FID) NMR signal is measured for the flowing stream in what is effectively a 'time-of-flight' measurement. The FID signal is then modelled as a function of fluid velocity and acquisition time, enabling determination of the velocity probability distributions via regularisation. The mean values of these velocity distributions were successfully validated against in-line rotameters. The ability to quantify multi-modal velocity distributions was also demonstrated using a two-pipe system.

  4. Some applications of magnetic resonance imaging in fluid mechanics: Complex flows and complex fluids

    NARCIS (Netherlands)

    Bonn, D.; Rodts, S.; Groenink, M.; Rafaï, S.; Shahidzadeh-Bonn, N.; Coussot, P.

    2008-01-01

    The review deals with applications of magnetic resonance imaging (MRI) techniques to study flow. We first briefly discuss the principles of flow measurement by MRI and give examples of some applications, such as multiphase flows, the MRI rheology of complex fluid flows, and blood flows in the human

  5. Intact plant magnetic resonance imaging to study dynamics in long-distance sap flow and flow-conducting surface area

    NARCIS (Netherlands)

    Scheenen, T.W.J.; Vergeldt, F.J.; Heemskerk, A.M.; As, van H.

    2007-01-01

    Due to the fragile pressure gradients present in the xylem and phloem, methods to study sap flow must be minimally invasive. Magnetic resonance imaging (MRI) meets this condition. A dedicated MRI method to study sap flow has been applied to quantify long-distance xylem flow and hydraulics in an

  6. Phase-Contrast Magnetic Resonance Angiography Measurements of Global Cerebral Blood Flow in the Neonate

    NARCIS (Netherlands)

    Benders, Manon J. N. L.; Hendrikse, Jeroen; de Vries, Linda S.; van Bel, Frank; Groenendaal, Floris

    2011-01-01

    Cerebral blood flow (CBF) alterations are important in pathogenesis of neonatal ischemic/hemorrhagic brain damage. In clinical practice, estimation of neonatal CBF is mostly based on Doppler-measured blood flow velocities in major intracranial arteries. Using phase-contrast magnetic resonance angiog

  7. Common Carotid Artery Flow Measured by 3-D Ultrasonic Vector Flow Imaging and Validated with Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Holbek, Simon; Hansen, Kristoffer Lindskov; Bouzari, Hamed

    2017-01-01

    Ultrasound (US) examination of the common carotid artery was compared with a through-plane magnetic resonance imaging (MRI) sequence to validate a recently proposed technique for 3-D US vector flow imaging. Data from the first volunteer examined were used as the training set, before volume flow a...

  8. Extraction of the magnetohydrodynamic blood flow potential from the surface electrocardiogram in magnetic resonance imaging.

    Science.gov (United States)

    Nijm, Grace M; Swiryn, Steven; Larson, Andrew C; Sahakian, Alan V

    2008-07-01

    The magnetohydrodynamic effect generates voltages related to blood flow, which are superimposed on the electrocardiogram (ECG) used for gating during cardiac magnetic resonance imaging (MRI). A method is presented for extracting the magnetohydrodynamic signal from the ECG. The extracted magnetohydrodynamic blood flow potential may be physiologically meaningful due to its relationship to blood flow. Removal of the magnetohydrodynamic voltages from the ECG can potentially lead to improved gating and diagnostically useful ECGs.

  9. Tomographic study of helical modes in bifurcating Taylor-Couette-Poiseuille flow using magnetic resonance imaging.

    Science.gov (United States)

    Moser, K W; Raguin, L G; Georgiadis, J G

    2001-07-01

    The quantitative visualization of flow in a wide-gap annulus (radius ratio 0.5) between concentric cylinders with the inner cylinder rotating and a superimposed axial flow reveals a novel mixed-mode state at relatively high flow rates. A fast magnetic resonance imaging sequence allows the cinematographic dissection and three-dimensional reconstruction of supercritical nonaxisymmetric modes in a regime where stationary helical and propagating toroidal vortices coexist. The findings shed light on symmetry-breaking instabilities, flow pattern selection, and their consequences for hydrodynamic mixing in a complex laminar flow that constitutes a celebrated prototype of many mixing or fractionation processes.

  10. The Role of Cine Flow Magnetic Resonance Imaging in Patients with Chiari 0 Malformation.

    Science.gov (United States)

    Ozsoy, Kerem Mazhar; Oktay, Kadir; Cetinalp, Nuri Eralp; Gezercan, Yurdal; Erman, Tahsin

    2016-12-14

    The aim of this study was to define the role of phase-contrast cine magnetic resonance imaging in deciding the therapeutic strategy and underlying pathophysiology resulting in syrinx formation in patients with Chiari type 0 malformation. Seven patients admitted to our clinic with diagnosis of Chiari 0 malformations during the period January 2005 to July 2016 were enrolled in the study. All patients underwent a detailed preoperative neurological examination. The entire neuroaxis magnetic resonance imaging and phase-contrast cine magnetic resonance imaging was obtained preoperatively and postoperatively. Seven patients (5 female and 2 male) cover the inclusion criteria of the Chiari type 0. All of the patients with Chiari type 0 malformation had absent cine flow at the craniovertebral junction except two patients. All these five patients underwent surgical interventions; suboccipital decompression and duraplasty. All of them showed both clinical and imaging improvements postoperatively. Cine flow magnetic resonance imaging appears to be a useful tool in the management of patients with Chiari 0 malformations. There was a good correlation between the clinical presentation and cine flow preoperatively, and between clinical improvement and cine flow postoperatively.

  11. 4-D flow magnetic resonance imaging: blood flow quantification compared to 2-D phase-contrast magnetic resonance imaging and Doppler echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Gabbour, Maya [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Medical Imaging 9, Chicago, IL (United States); Schnell, Susanne [Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Jarvis, Kelly [Northwestern University, Department of Biomedical Engineering, McCormick School of Engineering, Evanston, IL (United States); Robinson, Joshua D. [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Pediatrics, Division of Pediatric Cardiology, Chicago, IL (United States); Northwestern University Feinberg School of Medicine, Department of Pediatrics, Chicago, IL (United States); Markl, Michael [Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Northwestern University, Department of Biomedical Engineering, McCormick School of Engineering, Evanston, IL (United States); Rigsby, Cynthia K. [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Medical Imaging 9, Chicago, IL (United States); Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States)

    2015-06-15

    Doppler echocardiography (echo) is the reference standard for blood flow velocity analysis, and two-dimensional (2-D) phase-contrast magnetic resonance imaging (MRI) is considered the reference standard for quantitative blood flow assessment. However, both clinical standard-of-care techniques are limited by 2-D acquisitions and single-direction velocity encoding and may make them inadequate to assess the complex three-dimensional hemodynamics seen in congenital heart disease. Four-dimensional flow MRI (4-D flow) enables qualitative and quantitative analysis of complex blood flow in the heart and great arteries. The objectives of this study are to compare 4-D flow with 2-D phase-contrast MRI for quantification of aortic and pulmonary flow and to evaluate the advantage of 4-D flow-based volumetric flow analysis compared to 2-D phase-contrast MRI and echo for peak velocity assessment in children and young adults. Two-dimensional phase-contrast MRI of the aortic root, main pulmonary artery (MPA), and right and left pulmonary arteries (RPA, LPA) and 4-D flow with volumetric coverage of the aorta and pulmonary arteries were performed in 50 patients (mean age: 13.1 ± 6.4 years). Four-dimensional flow analyses included calculation of net flow and regurgitant fraction with 4-D flow analysis planes similarly positioned to 2-D planes. In addition, 4-D flow volumetric assessment of aortic root/ascending aorta and MPA peak velocities was performed and compared to 2-D phase-contrast MRI and echo. Excellent correlation and agreement were found between 2-D phase-contrast MRI and 4-D flow for net flow (r = 0.97, P < 0.001) and excellent correlation with good agreement was found for regurgitant fraction (r = 0.88, P < 0.001) in all vessels. Two-dimensional phase-contrast MRI significantly underestimated aortic (P = 0.032) and MPA (P < 0.001) peak velocities compared to echo, while volumetric 4-D flow analysis resulted in higher (aortic: P = 0.001) or similar (MPA: P = 0.98) peak

  12. Stochastic modeling for magnetic resonance quantification of myocardial blood flow

    Science.gov (United States)

    Seethamraju, Ravi T.; Muehling, Olaf; Panse, Prasad M.; Wilke, Norbert M.; Jerosch-Herold, Michael

    2000-10-01

    Quantification of myocardial blood flow is useful for determining the functional severity of coronary artery lesions. With advances in MR imaging it has become possible to assess myocardial perfusion and blood flow in a non-invasive manner by rapid serial imaging following injection of contrast agent. To date most approaches reported in the literature relied mostly on deriving relative indices of myocardial perfusion directly from the measured signal intensity curves. The central volume principle on the other hand states that it is possible to derive absolute myocardial blood flow from the tissue impulse response. Because of the sensitivity involved in deconvolution due to noise in measured data, conventional methods are sub-optimal, hence, we propose to use stochastic time series modeling techniques like ARMA to obtain a robust impulse response estimate. It is shown that these methods when applied for the optical estimation of the transfer function give accurate estimates of myocardial blood flow. The most significant advantage of this approach, compared with compartmental tracer kinetic models, is the use of a minimum set of prior assumptions on data. The bottleneck in assessing myocardial blood flow, does not lie in the MRI acquisition, but rather in the effort or time for post processing. It is anticipated that the very limited requirements for user input and interaction will be of significant advantage for the clinical application of these methods. The proposed methods are validated by comparison with mean blood flow measurements obtained from radio-isotope labeled microspheres.

  13. In vivo evaluation of femoral blood flow measured with magnetic resonance

    DEFF Research Database (Denmark)

    Henriksen, O; Ståhlberg, F; Thomsen, C;

    1989-01-01

    Quantitative measurements of blood flow based on magnetic resonance imaging (MRI) using conventional multiple spin echo sequences were evaluated in vivo in healthy young volunteers. Blood flow was measured using MRI in the femoral vein. The initial slope of the multiple spin echo decay curve...... that in vivo blood flow measurements made with MRI based on wash-out effects, commonly used in multiple spin echo imaging, do not give reliable absolute values for blood flow in the femoral artery or vein......., corrected for the T2 decay of non-flowing blood was used to calculate the blood flow. As a reference, the blood flow in the femoral artery was measured simultaneously with an invasive indicator dilution technique. T2 of non-flowing blood was measured in vivo in popliteal veins during regional circulatory...

  14. Magnetic resonance imaging (MRI: a technique to study flow an microstructure of concentrated emulsions

    Directory of Open Access Journals (Sweden)

    M. A. d'Avila

    2005-03-01

    Full Text Available Nuclear magnetic resonance (NMR and magnetic resonance imaging (MRI have recently been recognized as important techniques for R&D of products and processes, as is attested by several successful applications in different areas of chemical engineering in recent years. In this article we present new experimental methods based on MRI to study flow and microstructure of concentrated emulsions. The objective is to present the unique features of this noninvasive technique to accurately measure different properties of flowing particulate opaque systems. Experimental results of velocity profiles, spatial distribution of droplet sizes and spatial homogeneity of an oil-in-water dispersion in a horizontal, concentric cylinder geometry using different pulse sequences are presented. The application of these techniques allowed probing important information on flow and microstructure of multiphase systems of interest in chemical engineering and food science.

  15. Resonant behaviour of MHD waves on magnetic flux tubes. III - Effect of equilibrium flow

    Science.gov (United States)

    Goossens, Marcel; Hollweg, Joseph V.; Sakurai, Takashi

    1992-01-01

    The Hollweg et al. (1990) analysis of MHD surface waves in a stationary equilibrium is extended. The conservation laws and jump conditions at Alfven and slow resonance points obtained by Sakurai et al. (1990) are generalized to include an equilibrium flow, and the assumption that the Eulerian perturbation of total pressure is constant is recovered as the special case of the conservation law for an equilibrium with straight magnetic field lines and flow along the magnetic field lines. It is shown that the conclusions formulated by Hollweg et al. are still valid for the straight cylindrical case. The effect of curvature is examined.

  16. Measurement of Fluid Flow in Pipe and Porous Media by High-Resolution Magnetic Resonance Imaging

    Institute of Scientific and Technical Information of China (English)

    JIANG Lan-lan; SONG Yong-chen; LIU Yu; DOU Bin-lin; ZHU Ning-jun; ZHAO Jia-fei; BULITI Abudula

    2012-01-01

    The objective of this study is to understand the process of fluid flow in pipe and porous media with different pore structures.High-resolution Magnetic Resonance Imaging (MRI) technique was used to visualize the pore structure and measure fluid flow.The porous media was formed by packed bed of glass beads.Flow measurement was carried out by a modified spin echo sequence.The results show that the velocity distribution in pipe is annular and the linear relation between MRI velocity and actual velocity is found in pipe flow measurement.The flow distribution in porous media is rather heterogeneous,and it is consistent with heterogeneous pore structure.The flow through pores with the high volume flow rate is determined largely by geometrical effects such as pore size and cross-sectional area.

  17. The blood flow in the posterior communicant artery. Angiographic study by using magnetic resonance

    CERN Document Server

    Portela, L A P

    1995-01-01

    did not change the direction of flow present, in the circumstances of this study. The arterial circle of Willis is the most important collateral pathway for the cerebral vessels when one the afferents is occluded. Its normal function, without vascular compromise, has been considered in conflicting ways in the literature. For centuries after its description by Thomas Willis in 1664 it was considered a flow equalizer, with free admixture of blood within it. Since the beginning of this century the dominant view is one of a potential value only, with null effective flow in the communicating arteries. The premise is included in different experimental models. Alternatively, it was considered that the normal direction of flow is antero-posterior, from carotid to posterior cerebral, since carotid flow is greater. Using phase-contrast magnetic resonance angiography, a non-invasive qualitative method, it was found in 40 patients without morphological brain abnormality and in 10 healthy volunteers that flow can be seen ...

  18. Multidirectional flow analysis by cardiovascular magnetic resonance in aneurysm development following repair of aortic coarctation

    Directory of Open Access Journals (Sweden)

    Stalder Aurelien F

    2008-06-01

    Full Text Available Abstract Aneurysm formation is a life-threatening complication after operative therapy in coarctation. The identification of patients at risk for the development of such secondary pathologies is of high interest and requires a detailed understanding of the link between vascular malformation and altered hemodynamics. The routine morphometric follow-up by magnetic resonance angiography is a well-established technique. However, the intrinsic sensitivity of magnetic resonance (MR towards motion offers the possibility to additionally investigate hemodynamic consequences of morphological changes of the aorta. We demonstrate two cases of aneurysm formation 13 and 35 years after coarctation surgery based on a Waldhausen repair with a subclavian patch and a Vosschulte repair with a Dacron patch, respectively. Comprehensive flow visualization by cardiovascular MR (CMR was performed using a flow-sensitive, 3-dimensional, and 3-directional time-resolved gradient echo sequence at 3T. Subsequent analysis included the calculation of a phase contrast MR angiography and color-coded streamline and particle trace 3D visualization. Additional quantitative evaluation provided regional physiological information on blood flow and derived vessel wall parameters such as wall shear stress and oscillatory shear index. The results highlight the individual 3D blood-flow patterns associated with the different vascular pathologies following repair of aortic coarctation. In addition to known factors predisposing for aneurysm formation after surgical repair of coarctation these findings indicate the importance of flow sensitive CMR to follow up hemodynamic changes with respect to the development of vascular disease.

  19. Volumetric intake flow measurements of an IC engine using magnetic resonance velocimetry

    Science.gov (United States)

    Freudenhammer, Daniel; Baum, Elias; Peterson, Brian; Böhm, Benjamin; Jung, Bernd; Grundmann, Sven

    2014-05-01

    Magnetic resonance velocimetry (MRV) measurements are performed in a 1:1 scale model of a single-cylinder optical engine to investigate the volumetric flow within the intake and cylinder geometry during flow induction. The model is a steady flow water analogue of the optical IC-engine with a fixed valve lift of mm to simulate the induction flow at crank-angle bTDC. This setup resembles a steady flow engine test bench configuration. MRV measurements are validated with phase-averaged particle image velocimetry (PIV) measurements performed within the symmetry plane of the optical engine. Differences in experimental operating parameters between MRV and PIV measurements are well addressed. Comparison of MRV and PIV measurements is demonstrated using normalized mean velocity component profiles and showed excellent agreement in the upper portion of the cylinder chamber (i.e., mm). MRV measurements are further used to analyze the ensemble average volumetric flow within the 3D engine domain. Measurements are used to describe the 3D overflow and underflow behavior as the annular flow enters the cylinder chamber. Flow features such as the annular jet-like flows extending into the cylinder, their influence on large-scale in-cylinder flow motion, as well as flow recirculation zones are identified in 3D space. Inlet flow velocities are analyzed around the entire valve curtain perimeter to quantify percent mass flow rate entering the cylinder. Recirculation zones associated with the underflow are shown to reduce local mass flow rates up to 50 %. Recirculation zones are further analyzed in 3D space within the intake manifold and cylinder chamber. It is suggested that such recirculation zones can have large implications on cylinder charge filling and variations of the in-cylinder flow pattern. MRV is revealed to be an important diagnostic tool used to understand the volumetric induction flow within engine geometries and is potentially suited to evaluate flow changes due to intake

  20. Determining the flow regime in a biofilm carrier by means of magnetic resonance imaging.

    Science.gov (United States)

    Herrling, Maria P; Guthausen, Gisela; Wagner, Michael; Lackner, Susanne; Horn, Harald

    2015-05-01

    Biofilms on cylindrical carrier material originating from a lab-scale moving bed biofilm reactor (MBBR) were investigated by means of Magnetic Resonance Imaging (MRI). The aim of this study was to determine the local flow velocities at the inner face of the biofilm carrier. To get an insight into the mass transport processes, flow velocity maps of blank and with biofilm cultivated carriers were measured. A single carrier was placed in a tube in three different orientations and exposed to flow velocities of 0.21, 0.42, and 0.64 mm/s. The interplay of the biofilm morphology and the local flow pattern was then analyzed including the effect of the orientation of the carrier in relation to the upstream flow angle. Within this study, the biofilm carrier can be understood as an interconnected system of four sections in which the incoming fluid volume will be distributed depending on the biomass occupation and morphology. In sections with high biofilm occupation, the flow resistance is increased. Depending on the orientation of the carrier in the flow field, this effect leads to flow evasion through less covered sections showing higher flow velocities and consequently the risk of biofilm detachment. However, there was no clear correlation between biofilm coverage and flow ratio.

  1. Magnetic resonance imaging of flow and mass transfer in electrohydrodynamic liquid bridges

    CERN Document Server

    Wexler, Adam D; Fuchs, Elmar C; Woisetschläger, Jakob; Reiter, Gert; Fuchsjäger, Michael; Reiter, Ursula

    2016-01-01

    Here we report on the feasibility and use of magnetic resonance imaging based methods to the study of electrohydrodynamic (EHD) liquid bridges. High speed tomographic recordings through the longitudinal axis of water bridges were used to characterize the mass transfer dynamics, mixing, and flow structure. By filling one beaker with heavy water and the other with light water it was possible to track the spread of the proton signal throughout the total liquid volume. The mixing kinetics are different depending on where the light nuclei are located and proceeds faster when the anolyte is light water. Distinct flow and mixing regions are identified in the fluid volumes and it is shown that the EHD flow at the electrodes can be counteracted by the density difference between water isotopes. MR phase contrast imaging reveals that within the bridge section two separate counter propagating flows pass one above the other in the bridge.

  2. MRI (Magnetic Resonance Imaging)

    Science.gov (United States)

    ... and Procedures Medical Imaging MRI (Magnetic Resonance Imaging) MRI (Magnetic Resonance Imaging) Share Tweet Linkedin Pin it More sharing options ... usually given through an IV in the arm. MRI Research Programs at FDA Magnetic Resonance Imaging (MRI) ...

  3. Velocity measurements of flow through a step stenosis using Magnetic Resonance Imaging

    Science.gov (United States)

    Moser, K. W.; Kutter, E. C.; Georgiadis, J. G.; Buckius, R. O.; Morris, H. D.; Torczynski, J. R.

    Magnetic resonance imaging (MRI) is a versatile noninvasive tool for achieving full-field quantitative visualization of complex fluid flows. The MRI signal results from the interaction of radio-frequency (RF) pulses with nuclear spins exposed to a strong static magnetic field. The two main techniques of MRI velocimetry are time-of-flight and phase contrast techniques. Time-of- flight techniques involve tagging and tracking a material volume of fluid, whereas phase contrast techniques use magnetic field gradients to encode velocity information into the phase of the MRI signal. In this study, both techniques are used to probe the pressure-driven steady flow of water in a pipe with a step stenosis. The velocity measurements were then compared with computational results obtained using the FIDAP software package. The experiments show that the phase contrast method gives more accurate results, with 90% of the measurements within 10% of the local computational fluid dynamics (CFD) velocity predictions at Re=100 and 94% of the measurements within 10% of the local CFD predictions at Re=258. Although the time-of-flight experiments were not as accurate, they provide a good qualitative image of the flow field. Sources of the discrepancies between the MRI data and the CFD results are also discussed, including acceleration and spin flow-through artifacts.

  4. Velocity measurements of flow through a step stenosis using Magnetic Resonance Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Moser, K.W.; Kutter, E.C.; Georgiadis, J.G.; Buckius, R.O. [Illinois Univ., Urbana, IL (United States). Dept. of Mechanical and Industrial Engineering; Morris, H.D. [Biomedical Magnetic Resonance Laboratory University of Illinois at Urbana-Champaign 2100 South Goodwin Avenue Urbana, IL 61801 (United States); Torczynski, J.R. [Engineering Sciences Center, Sandia National Laboratories P.O. Box 5800, Albuquerque, NM 87185-0834 (United States)

    2000-11-01

    Magnetic resonance imaging (MRI) is a versatile noninvasive tool for achieving full-field quantitative visualization of complex fluid flows. The MRI signal results from the interaction of radio-frequency (RF) pulses with nuclear spins exposed to a strong static magnetic field. The two main techniques of MRI velocimetry are time-of-flight and phase contrast techniques. Time-of- flight techniques involve tagging and tracking a material volume of fluid, whereas phase contrast techniques use magnetic field gradients to encode velocity information into the phase of the MRI signal. In this study, both techniques are used to probe the pressure-driven steady flow of water in a pipe with a step stenosis. The velocity measurements were then compared with computational results obtained using the FIDAP software package. The experiments show that the phase contrast method gives more accurate results, with 90% of the measurements within 10% of the local computational fluid dynamics (CFD) velocity predictions at Re=100 and 94% of the measurements within 10% of the local CFD predictions at Re=258. Although the time-of-flight experiments were not as accurate, they provide a good qualitative image of the flow field. Sources of the discrepancies between the MRI data and the CFD results are also discussed, including acceleration and spin flow-through artifacts. (orig.)

  5. Magnetic Resonance Imaging-derived Flow Parameters for the Analysis of Cardiovascular Diseases and Drug Development.

    Science.gov (United States)

    Michael, Dada O; Bamidele, Awojoyogbe O; Adewale, Adesola O; Karem, Boubaker

    2013-01-01

    Nuclear magnetic resonance (NMR) allows for fast, accurate and noninvasive measurement of fluid flow in restricted and non-restricted media. The results of such measurements may be possible for a very small B 0 field and can be enhanced through detailed examination of generating functions that may arise from polynomial solutions of NMR flow equations in terms of Legendre polynomials and Boubaker polynomials. The generating functions of these polynomials can present an array of interesting possibilities that may be useful for understanding the basic physics of extracting relevant NMR flow information from which various hemodynamic problems can be carefully studied. Specifically, these results may be used to develop effective drugs for cardiovascular-related diseases.

  6. Cine phase-contrast magnetic resonance imaging for analysis of flow phenomena in experimental aortic dissection.

    Science.gov (United States)

    Iwai, F; Sostman, H D; Evans, A J; Nadel, S N; Hedlund, L W; Beam, C A; Charles, H C; Spritzer, C E

    1991-12-01

    Using a 1.5 T magnetic resonance imaging (MRI) system, cine phase-contrast and magnitude images were obtained in three phantoms that simulated different anatomic configurations of aortic dissection. The dissection phantoms were made of compliant materials, and pulsatile flow was used in all experiments. Phantoms differed only in the location of the fenestration between the true and false lumens (I: an upstream "entry" only, II: both upstream "entry" and downstream "re-entry," and III: a downstream "entry" only). Flow jets, flap motion, and wave propagation were clearly visualized in cine MR images of each phantom, and quantitatively analyzed with reference to the stimulated cardiac cycle of the pump. Flow in the false lumen was always bidirectional. Upstream and downstream flow waves collided and dispersed within the false lumen. Flow through the false lumen was the same in phantoms I and II, and least in phantom III. The average area of the true lumen was largest in phantom III and smallest in I. Phantom I had the highest overall flow rate in the false lumen and greatest change in false lumen size during the cardiac cycle, while the downstream "entry" phantom had the lowest of both parameters. Flow phenomena in aortic dissections can be studied by cine phase-contrast MRI.

  7. 4D magnetic resonance flow imaging for estimating pulmonary vascular resistance in pulmonary hypertension.

    Science.gov (United States)

    Kheyfets, Vitaly O; Schafer, Michal; Podgorski, Chris A; Schroeder, Joyce D; Browning, James; Hertzberg, Jean; Buckner, J Kern; Hunter, Kendal S; Shandas, Robin; Fenster, Brett E

    2016-10-01

    To develop an estimate of pulmonary vascular resistance (PVR) using blood flow measurements from 3D velocity-encoded phase contract magnetic resonance imaging (here termed 4D MRI). In all, 17 patients with pulmonary hypertension (PH) and five controls underwent right heart catheterization (RHC), 4D and 2D Cine MRI (1.5T) within 24 hours. MRI was used to compute maximum spatial peak systolic vorticity in the main pulmonary artery (MPA) and right pulmonary artery (RPA), cardiac output, and relative area change in the MPA. These parameters were combined in a four-parameter multivariate linear regression model to arrive at an estimate of PVR. Agreement between model predicted and measured PVR was also evaluated using Bland-Altman plots. Finally, model accuracy was tested by randomly withholding a patient from regression analysis and using them to validate the multivariate equation. A decrease in vorticity in the MPA and RPA were correlated with an increase in PVR (MPA: R(2) = 0.54, P < 0.05; RPA: R(2) = 0.75, P < 0.05). Expanding on this finding, we identified a multivariate regression equation that accurately estimates PVR (R(2) = 0.94, P < 0.05) across severe PH and normotensive populations. Bland-Altman plots showed 95% of the differences between predicted and measured PVR to lie within 1.49 Wood units. Model accuracy testing revealed a prediction error of ∼20%. A multivariate model that includes MPA relative area change and flow characteristics, measured using 4D and 2D Cine MRI, offers a promising technique for noninvasively estimating PVR in PH patients. J. MAGN. RESON. IMAGING 2016;44:914-922. © 2016 International Society for Magnetic Resonance in Medicine.

  8. Dynamic Contrast-Enhanced Magnetic Resonance Imaging of Tumor-Induced Lymph Flow

    Directory of Open Access Journals (Sweden)

    Alanna Ruddell

    2008-07-01

    Full Text Available The growth of metastatic tumors in mice can result in markedly increased lymph flow through tumor-draining lymph nodes (LNs, which is associated with LN lymphangiogenesis. A dynamic magnetic resonance imaging (MRI assay was developed, which uses low.molecular weight gadolinium contrast agent to label the lymphatic drainage, to visualize and quantify tumor-draining lymph flow in vivo in mice bearing metastatic melanomas. Tumor-bearing mice showed greatly increased lymph flow into and through draining LNs and into the bloodstream. Quantitative analysis established that both the amount and the rate of lymph flow through draining LNs are significantly increased in melanoma-bearing mice. In addition, the rate of appearance of contrast media in the bloodstream was significantly increased in mice bearing melanomas. These results indicate that gadolinium-based contrast-enhanced MRI provides a noninvasive assay for high-resolution spatial identification and mapping of lymphatic drainage and for dynamic measurement of changes in lymph flow associated with cancer or lymphatic dysfunction in mice. Low-molecular weight gadolinium contrast is already used for 1.5-T MRI scanning in humans, which should facilitate translation of this imaging assay.

  9. Visualization of vacuum cleaner-induced flow in a carpet by using magnetic resonance velocimetry

    Science.gov (United States)

    Lee, Jeesoo; Song, Simon

    2016-11-01

    Understanding characteristics of in-carpet flow induced by a vacuum cleaner nozzle is important to improve the design and performance of the cleaner nozzle. However, optical visualization techniques like PIV are limited to uncover the flow details because a carpet is opaque porous media. We have visualized a mean flow field in a cut-pile type carpet by magnetic resonance velocimetry. The flow was generated by a static vacuum cleaner nozzle, and the working fluid is a copper sulfate aqueous solution. Three dimensional, three component velocity vectors were obtained in a measurement domain of 336 x 128 x 14 mm3 covering the entire nozzle span and a 7-mm thick carpet below the nozzle. The voxel size was 1 x 1 x 0.5 (depthwise) mm3. Based on the visualization data, the permeability, the Forchheimer coefficient and pressure distribution were calculated for the carpet. This work was supported by the National Research Foundation of Korea (NRF) Grant funded by the Korea government (MSIP) (No. 2016R1A2B3009541).

  10. Cine magnetic resonance imaging for evaluation of cardiac structure and flow dynamics in congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Akagi, Teiji; Kiyomatsu, Yumi; Ohara, Nobutoshi; Takagi, Junichi; Sato, Noboru; Kato, Hirohisa (Kurume Univ., Fukuoka (Japan). School of Medicine); Eto, Takaharu

    1989-10-01

    Cine magnetic resonance imaging (Cine MRI) was performed in 20 patients aged 19 days to 13 years (mean 4.0 years), who had congenital heart disease confirmed at echocardiography or angiography. Prior to cine MRI, gated MRI was performed to evaluate for cardiac structure. Cine MRI was demonstrated by fast low fip angle shot imaging technique with a 30deg flip angle, 15 msec echo time, 30-40 msec pulse repetition time, and 128 x 128 acquisition matrix. Abnormalities of cardiac structure were extremely well defined in all patients by gated MRI. Intracardiac or intravascular blood flow were visualized in 17 (85%) of 20 patients by cine MRI. Left to right shunt flow through ventricular septal defect, atrial septal defect, and endocardial cushion defect were visualized with low signal intensity area. Low intensity jets flow through the site of re-coarctation of the aorta were also visualized. However, the good recording of cine MRI was not obtained because of artifacts in 3 of 20 patients (15%) who had severe congestive heart failure or respiratory arrhythmia. Gated MRI provides excellent visualization of fine structure, and cine MRI can provide high spatial resolution imaging of flow dynamic in a variety of congenital heart disease, noninvasively. (author).

  11. Measurement of cerebral blood flow using phase contrast magnetic resonance imaging and duplex ultrasonography.

    Science.gov (United States)

    Khan, Muhammad Ayaz; Liu, Jie; Tarumi, Takashi; Lawley, Justin Stevan; Liu, Peiying; Zhu, David C; Lu, Hanzhang; Zhang, Rong

    2017-02-01

    Phase contrast magnetic resonance imaging (PC-MRI) and color-coded duplex ultrasonography (CDUS) are commonly used for measuring cerebral blood flow in the internal carotid (ICA) and vertebral arteries. However, agreement between the two methods has been controversial. Recent development of high spatial and temporal resolution blood vessel wall edge-detection and wall-tracking methods with CDUS increased the accuracy and reliability of blood vessel diameter, hence cerebral blood flow measurement. The aim of this study was to compare the improved CDUS method with 3 T PC-MRI for cerebral blood flow measurements. We found that cerebral blood flow velocity measured in the ICA was lower using PC-MRI than CDUS (left ICA: PC-MRI, 18.0 ± 4.2 vs. CDUS, 25.6 ± 8.6 cm/s; right ICA: PC-MRI, 18.5 ± 4.8 vs. CDUS, 26.6 ± 6.7 cm/s, both p blood flow velocity measured in the left vertebral artery with PC-MRI was also lower than CDUS, but no differences in vertebral artery diameter were observed between the methods. Dynamic changes and/or intrinsic physiological fluctuations may have caused these differences in vessel diameter and velocity measurements between the methods. However, estimation of volumetric cerebral blood flow was similar and correlated between the methods despite the presence of large individual differences. These findings support the use of CDUS for cerebral blood flow measurements in the ICA and vertebral artery.

  12. Valve morphology effect in aortic coarctation flow using realistic silicon models and magnetic resonance imaging

    Science.gov (United States)

    Marrufo, Oscar; Solis-Najera, Sergio; Pibarot, Philippe; Kadem, Lyes; Kesharvarz-Motamed, Zahra; Rodriguez, Alfredo O.; Garcia, Julio

    2014-11-01

    Aortic valve morphology and phenotype may alter the aortic wall structure and its normal flow hemodynamics. However, the relationship between altered flow patterns and progression of wall pathology is often not fully understood in patients with aortic coartation and needs larger experimental work. In this study, we introduced a compatible experimental setup with magnetic resonance imaging (MRI) using a realistic aortic coarctation (AoCo) silicon model which can replicate physiological flow conditions (pressure, flow-wave, and systemic load). We evaluated the aortic valve hemodynamics of a normal tricuspid valve and a stenotic bicuspid valve using valve effective orifice area (EOA), peak and mean transvalvular pressure gradient (TPG). AoCo severity was assessed by the AoCo pressure gradient. For the tricuspid valve we obtained an EOA = 1.89 cm2, a peak TPG = 10 mmHg, and a mean TPG = 5 mmHg. For the bicuspid valve we obtained an EOA = 1.03 cm2, a peak TPG = 37 mmHg and a mean TPG = 13 mmHg. Furthermore, AoCo with tricuspid valve led to a peak AoCo pressure gradient (PG) = 11 mmHg and a mean PG = 5 mmHg. AoCo with bicuspid valve led to a peak PG = 6 mmHg and a mean PG = 3 mmHg. Aortic flow reattachment was more evident in presence of bicuspid valve and helical flow was present in all cases. This study showed that silicon prototyping in combination with MRI velocity measurements could successfully be used to assess hemodynamic effects of aortic valve morphology in aortic coarctation flow.

  13. Flow and distension in the carotid artery from magnetic resonance imaging

    Science.gov (United States)

    Yim, Peter J.; Demarco, J. K.

    2004-04-01

    Hemodynamic conditions in the carotid artery may be associated with progression of carotid artery (CA) disease and with the risk of stroke. A methodology for objective measurement of distension (DCA) and blood-flow (QCA) waveform from phase-contrast (PC) magnetic resonance (MR) imaging is presented. Measurement of DCA is obtained using a modified Hough Transform (mHT) applied to the magnitude-component of the PC MR. The mHT is based on the optimization of an objective function which is the sum of the gradient magnitude of the image sampled at 10° increments around the circle using bilinear interpolation. The mHT detects the boundary of the vessel in the cross-sectional image at 0.05-pixel resolution. Measurement of QCA is obtained by integration of the image intensity in the phase-component of the PC MR within the circular region detected by the mHT.

  14. Helical electric potential modulation via zonal-flow coupling to resonant magnetic perturbations

    Science.gov (United States)

    Leconte, M.; Kim, J.-H.

    2017-08-01

    Helical modulations of the electric potential were observed in several devices during application of resonant magnetic perturbations (RMPs). To address the implication of the helical modulation on RMP-induced transport, we derive a system of 1D equations for zonal flows (ZFs) and helical potential in the presence of RMPs. As ZFs are turbulence-driven, turbulence plays a major role in this plasma self-organization towards a quasi-equilibrium with 3D helical potential. The model reveals how RMPs modify an initially given a saturated-state of coexisting turbulence and ZFs. It is shown that RMPs trigger a transport bifurcation by allowing energy-transfer out of turbulence-driven ZFs into ZF-driven helical potential.

  15. Magnetic Resonance Flow Velocity and Temperature Mapping of a Shape Memory Polymer Foam Device

    Energy Technology Data Exchange (ETDEWEB)

    Small IV, W; Gjersing, E; Herberg, J L; Wilson, T S; Maitland, D J

    2008-10-29

    Interventional medical devices based on thermally responsive shape memory polymer (SMP) are under development to treat stroke victims. The goals of these catheter-delivered devices include re-establishing blood flow in occluded arteries and preventing aneurysm rupture. Because these devices alter the hemodynamics and dissipate thermal energy during the therapeutic procedure, a first step in the device development process is to investigate fluid velocity and temperature changes following device deployment. A laser-heated SMP foam device was deployed in a simplified in vitro vascular model. Magnetic resonance imaging (MRI) techniques were used to assess the fluid dynamics and thermal changes associated with device deployment. Spatial maps of the steady-state fluid velocity and temperature change inside and outside the laser-heated SMP foam device were acquired. Though non-physiological conditions were used in this initial study, the utility of MRI in the development of a thermally-activated SMP foam device has been demonstrated.

  16. Measurement of Two Phase Flow in Porous Medium Using High-resolution Magnetic Resonance Imaging

    Institute of Scientific and Technical Information of China (English)

    JIANG Lanlan; SONG Yongchen; LIU Yu; YANG Mingjun; ZHU Ningjun; WANG Xiaojing; DOU Binlin

    2013-01-01

    Measurement of two phase flow in porous medium for sequestration was carried out using high-resolution magnetic resonance imaging (MRI) technique.The porous medium was a packed bed of glass beads.Spin echo multi sequence was used to measure the distribution of CO2 and water in the porous medium.The intensity images show that the fluid distribution is non-uniform due to its viscosity and pore structure of porous medium.The velocity distribution of fluids is calculated from the saturation of water and porosity of porous medium.The experimental results show that fluid velocities vary with time and position.The capillary dispersion rate donated the effects of capillary,which was largest at water saturations of 0.45.The displacement process is different between in BZ-02 and BZ-2.The final water residual saturation depends on permeability and porosity.

  17. Real-time magnetic resonance imaging of deep venous flow during muscular exercise—preliminary experience

    Science.gov (United States)

    Merboldt, Klaus-Dietmar; Voit, Dirk; Dahm, Johannes; Frahm, Jens

    2016-01-01

    Background The accurate assessment of peripheral venous flow is important for the early diagnosis and treatment of disorders such as deep-vein thrombosis (DVT) which is a major cause of post-thrombotic syndrome or even death due to pulmonary embolism. The aim of this work is to quantitatively determine blood flow in deep veins during rest and muscular exercise using a novel real-time magnetic resonance imaging (MRI) method for velocity-encoded phase-contrast (PC) MRI at high spatiotemporal resolution. Methods Real-time PC MRI of eight healthy volunteers and one patient was performed at 3 Tesla (Prisma fit, Siemens, Erlangen, Germany) using a flexible 16-channel receive coil (Variety, NORAS, Hoechberg, Germany). Acquisitions were based on a highly undersampled radial FLASH sequence with image reconstruction by regularized nonlinear inversion at 0.5×0.5×6 mm3 spatial resolution and 100 ms temporal resolution. Flow was assessed in two cross-sections of the lower leg at the level of the calf muscle and knee using a protocol of 10 s rest, 20 s flexion and extension of the foot, and 10 s rest. Quantitative analyses included through-plane flow in the right posterior tibial, right peroneal and popliteal vein (PC maps) as well as signal intensity changes due to flow and muscle movements (corresponding magnitude images). Results Real-time PC MRI successfully monitored the dynamics of venous flow at high spatiotemporal resolution and clearly demonstrated increased flow in deep veins in response to flexion and extension of the foot. In normal subjects, the maximum velocity (averaged across vessel lumen) during exercise was 9.4±5.7 cm·s−1 for the right peroneal vein, 8.5±4.6 cm·s−1 for the right posterior tibial vein and 17.8±5.8 cm·s−1 for the popliteal vein. The integrated flow volume per exercise (20 s) was 1.9, 1.6 and 50 mL (mean across subjects) for right peroneal, right posterior tibial and popliteal vein, respectively. A patient with DVT presented with

  18. Vertigo-related cerebral blood flow changes on magnetic resonance imaging.

    Science.gov (United States)

    Chang, Feiyan; Li, Zhongshi; Xie, Sheng; Liu, Hui; Wang, Wu

    2014-11-01

    A prospective study using magnetic resonance imaging on a consecutive cohort of patients with cervical vertigo. To quantitatively investigate the cerebral blood flow (CBF) changes associated with cervical vertigo by using 3-dimensional pseudocontinuous arterial spin labeling. Previous studies reported blood flow velocity reduction in posterior circulation during vertigo. However, the detailed information of CBF related to cervical vertigo has not been provided. A total of 33 patients with cervical vertigo and 14 healthy volunteers were recruited in this study. Three-dimensional pseudocontinuous arterial spin labeling was performed on each subject to evaluate the CBF before and after the cervical hyperextension-hyperflexion movement tests, which was used to induce cervical vertigo. Repeated-measures analysis of variance was conducted to assess the effect of subjects and tests. There were time effects of CBF in the territory of bilateral superior cerebellar artery, bilateral posterior cerebral artery, bilateral middle cerebral artery, and right anterior cerebral artery, but no group effect was observed. The analysis of CBF revealed a significant main effect of tests (P=0.024) and participants (P=0.038) in the dorsal pons. Cervical vertigo onset may be related to CBF reduction in the dorsal pons, which sequentially evokes the vestibular nuclei. 2.

  19. Quantitative myocardial perfusion magnetic resonance imaging: the impact of pulsatile flow on contrast agent bolus dispersion

    Energy Technology Data Exchange (ETDEWEB)

    Graafen, Dirk; Hamer, Julia; Weber, Stefan; Schreiber, Laura M, E-mail: graafen@uni-mainz.de [Section of Medical Physics, Department of Radiology, Johannes Gutenberg University Medical Center, Mainz (Germany)

    2011-08-21

    Myocardial blood flow (MBF) can be quantified using T{sub 1}-weighted first-pass magnetic resonance imaging (MRI) in combination with a tracer-kinetic model, like MMID4. This procedure requires the knowledge of an arterial input function which is usually estimated from the left ventricle (LV). Dispersion of the contrast agent bolus may occur between the LV and the tissue of interest. The aim of this study was to investigate the dispersion under conditions of physiological pulsatile blood flow, and to simulate its effect on MBF quantification. The dispersion was simulated in coronary arteries using a computational fluid dynamics (CFD) approach. Simulations were accomplished on straight vessels with stenosis of different degrees and shapes. The results show that dispersion is more pronounced under resting conditions than during hyperemia. Stenosis leads to a reduction of dispersion. In consequence, dispersion results in a systematic MBF underestimation between -0.4% and -9.3%. The relative MBF error depends not only on the dispersion but also on the actual MBF itself. Since MBF under rest is more underestimated than under stress, myocardial perfusion reserve is overestimated between 0.1% and 4.5%. Considering other sources of errors in myocardial perfusion MRI, systematic errors of MBF by bolus dispersion are relatively small.

  20. MRI (Magnetic Resonance Imager)

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Yoshinori [Toshiba Corp., Kawasaki, Kanagawa (Japan)

    1995-05-01

    MRI is a widely used diagnostic imaging modality because it has excellent diagnostic capabilities, is safe to use and generates images not affected by bone artifacts. Images are obtained by utilizing the phenomenon of Nuclear Magnetic Resonance (NMR) by which protons located in a static magnetic field absorb radio frequency (RF) pulses with a specific frequency and release a part of the energy as a NMR signal. Potentially MRI has the ability to provide functional and metabolic information (such as flow, temperature, diffusion, neuron activity) in addition to morphological information. This paper describes the imaging principles and provides a general outline of some applications: flow imaging, metabolite imaging and temperature imaging. (J.P.N.).

  1. Optimal velocity encoding during measurement of cerebral blood flow volume using phase-contrast magnetic resonance angiography

    Institute of Scientific and Technical Information of China (English)

    Gang Guo; Yonggui Yang; Weiqun Yang

    2011-01-01

    This study investigated the effect of velocity encoding on measurement of brain blood flow and blood volume of inflow and outflow using phase-contrast magnetic resonance angiography. A single two-dimensional phase-contrast magnetic resonance angiography slice was applied perpendicular to the internal carotid artery and the vertebral artery at C2 level. For each subject, the velocity encoding was set from 30 to 90 cm/s with an interval of 10 cm/s for a total of seven settings. Various velocity encodings greatly affected blood flow volume, maximal blood flow velocity and mean blood flow velocity in the internal carotid artery, but did not significantly affect vertebral arteries and jugular veins. When velocity encoding was 60-80 cm/s, the inflow blood volume was 655 ± 118 mL/min, and the outflow volume was 506 ± 186 mL/min. The ratio of outflow/inflow was steady at 0.78-0.83, and there was no aliasing in any of the images. These findings suggest that velocity encodings of 60-80 cm/s should be selected during measurement of cerebral blood flow volume using phase-contrast magnetic resonance angiography.

  2. Magnetic resonance flow velocity and temperature mapping of a shape memory polymer foam device

    Directory of Open Access Journals (Sweden)

    Wilson Thomas S

    2009-12-01

    Full Text Available Abstract Background Interventional medical devices based on thermally responsive shape memory polymer (SMP are under development to treat stroke victims. The goals of these catheter-delivered devices include re-establishing blood flow in occluded arteries and preventing aneurysm rupture. Because these devices alter the hemodynamics and dissipate thermal energy during the therapeutic procedure, a first step in the device development process is to investigate fluid velocity and temperature changes following device deployment. Methods A laser-heated SMP foam device was deployed in a simplified in vitro vascular model. Magnetic resonance imaging (MRI techniques were used to assess the fluid dynamics and thermal changes associated with device deployment. Results Spatial maps of the steady-state fluid velocity and temperature change inside and outside the laser-heated SMP foam device were acquired. Conclusions Though non-physiological conditions were used in this initial study, the utility of MRI in the development of a thermally-activated SMP foam device has been demonstrated.

  3. Assessment of differential pulmonary blood flow using perfusion magnetic resonance imaging: comparison with radionuclide perfusion scintigraphy.

    Science.gov (United States)

    Molinari, Francesco; Fink, Christian; Risse, Frank; Tuengerthal, Siegfried; Bonomo, Lorenzo; Kauczor, Hans-Ulrich

    2006-08-01

    We sought to assess the agreement between lung perfusion ratios calculated from pulmonary perfusion magnetic resonance imaging (MRI) and those calculated from radionuclide (RN) perfusion scintigraphy. A retrospective analysis of MR and RN perfusion scans was conducted in 23 patients (mean age, 60 +/- 14 years) with different lung diseases (lung cancer = 15, chronic obstructive pulmonary disease = 4, cystic fibrosis = 2, and mesothelioma = 2). Pulmonary perfusion was assessed by a time-resolved contrast-enhanced 3D gradient-echo pulse sequence using parallel imaging and view sharing (TR = 1.9 milliseconds; TE = 0.8 milliseconds; parallel imaging acceleration factor = 2; partition thickness = 4 mm; matrix = 256 x 96; in-plane spatial resolution = 1.87 x 3.75 mm; scan time for each 3D dataset = 1.5 seconds), using gadolinium-based contrast agents (injection flow rate = 5 mL/s, dose = 0.1 mmol/kg of body weight). The peak concentration (PC) of the contrast agent bolus, the pulmonary blood flow (PBF), and blood volume (PBV) were computed from the signal-time curves of the lung. Left-to-right ratios of pulmonary perfusion were calculated from the MR parameters and RN counts. The agreement between these ratios was assessed for side prevalence (sign test) and quantitatively (Deming-regression). MR and RN ratios agreed on side prevalence in 21 patients (91%) with PC, in 20 (87%) with PBF, and in 17 (74%) with PBV. The MR estimations of left-to-right perfusion ratios correlated significantly with those of RN perfusion scans (P lung. Further studies in a larger group of patients are required to fully confirm the clinical suitability of this imaging method.

  4. Pulsatile cerebrospinal fluid flow measurement using phase-contrast magnetic resonance imaging in patients with cervical myelopathy.

    Science.gov (United States)

    Shibuya, Ryoichi; Yonenobu, Kazuo; Koizumi, Toshiaki; Kato, Yasuji; Mitta, Motoharu; Yoshikawa, Hideki

    2002-05-15

    A technical report is presented. To investigate the relation between the severity of myelopathy and the degree of cerebrospinal fluid flow disturbance by using magnetic resonance imaging to measure the velocity of the cerebrospinal fluid flow in patients with cervical spondylotic myelopathy. Analyses of pulsatile cerebrospinal fluid flow measured by phase-contrast magnetic resonance imaging in healthy subjects and patients with Arnold-Chiari syndrome have been reported. Few studies have evaluated the change of pulsatile cerebrospinal fluid flow velocity and the waveform of the plotted velocity in patients with cervical spondylotic myelopathy. Study 1: Pulsatile cerebrospinal fluid flow was measured at C7, positioned with cervical spine flexion and extension, to investigate the influence of cervical alignment on the pulsatile cerebrospinal fluid flow in five patients with cervical spondylotic myelopathy. Study 2: In 31 patients with cervical spondylotic myelopathy, pulsatile cerebrospinal fluid flow was measured at C3 and C7, with the neck set centrally. The relevance of cerebrospinal fluid flow disturbance and the severity of myelopathy evaluated by the Japanese Orthopedic Association scoring system also were studied. Study 1: The waveform of plotted pulsatile cerebrospinal fluid flow velocity showed no change resulting from the position of the cervical spine. Study 2: A high correlation between the Japanese Orthopedic Association score and the cerebrospinal fluid pulsatile flow amplitude at C7 was demonstrated (r = 0.75; P < 0.0001). The average Japanese Orthopedic Association score of 14 patients whose cerebrospinal fluid flow velocity waveforms were absent was significantly lower (P < 0.0001) than that of 17 patients whose waveforms were present. The disturbance of pulsatile cerebrospinal fluid flow demonstrated high correlation with the severity of myelopathy. Measurement of cerebrospinal fluid flow disturbance can quantify the degree of dural sac and spinal

  5. Peak flow velocities in the ascending aorta-real-time phase-contrast magnetic resonance imaging vs. cine magnetic resonance imaging and echocardiography.

    Science.gov (United States)

    Sohns, Jan M; Kowallick, Johannes T; Joseph, Arun A; Merboldt, K Dietmar; Voit, Dirk; Fasshauer, Martin; Staab, Wieland; Frahm, Jens; Lotz, Joachim; Unterberg-Buchwald, Christina

    2015-10-01

    This prospective study of eight healthy volunteers evaluates peak flow velocities (PFV) in the ascending aorta using real-time phase-contrast magnetic resonance imaging (MRI) in comparison to cine phase-contrast MRI and echocardiography. Flow measurements by echocardiography and cine phase-contrast MRI with breath-holding were performed according to clinical standards. Real-time phase-contrast MRI at 40 ms temporal resolution and 1.3 mm in-plane resolution was based on highly undersampled radial fast low-angle shot (FLASH) sequences with image reconstruction by regularized nonlinear inversion (NLINV). Evaluations focused on the determination of PFV. Linear regressions and Bland-Altman plots were used for comparisons of methods. When averaged across subjects, real-time phase-contrast MRI resulted in PFV of 120±20 cm s(-1) (mean ± SD) in comparison to 122±16 cm s(-1) for cine MRI and 124±20 cm s(-1) for echocardiography. The maximum deviations between real-time phase-contrast MRI and echocardiography ranged from -20 to +14 cm s(-1) (cine MRI: -10 to +12 cm s(-1)). Thus, in general, real-time phase-contrast MRI of cardiac outflow revealed quantitative agreement with cine MRI and echocardiography. The advantages of real-time MRI are measurements during free breathing and access to individual cardiac cycles.

  6. Cardiovascular Magnetic Resonance Imaging

    Science.gov (United States)

    Pelc, Norbert

    2000-03-01

    Cardiovascular diseases are a major source of morbidity and mortality in the United States. Early detection of disease can often be used to improved outcomes, either through direct interventions (e.g. surgical corrections) or by causing the patient to modify his or her behavior (e.g. smoking cessation or dietary changes). Ideally, the detection process should be noninvasive (i.e. it should not be associated with significant risk). Magnetic Resonance Imaging (MRI) refers to the formation of images by localizing NMR signals, typically from protons in the body. As in other applications of NMR, a homogeneous static magnetic field ( ~0.5 to 4 T) is used to create ``longitudinal" magnetization. A magnetic field rotating at the Larmor frequency (proportional to the static field) excites spins, converting longitudinal magnetization to ``transverse" magnetization and generating a signal. Localization is performed using pulsed gradients in the static field. MRI can produce images of 2-D slices, 3-D volumes, time-resolved images of pseudo-periodic phenomena such as heart function, and even real-time imaging. It is also possible to acquire spatially localized NMR spectra. MRI has a number of advantages, but perhaps the most fundamental is the richness of the contrast mechanisms. Tissues can be differentiated by differences in proton density, NMR properties, and even flow or motion. We also have the ability to introduce substances that alter NMR signals. These contrast agents can be used to enhance vascular structures and measure perfusion. Cardiovascular MRI allows the reliable diagnosis of important conditions. It is possible to image the blood vessel tree, quantitate flow and perfusion, and image cardiac contraction. Fundamentally, the power of MRI as a diagnostic tool stems from the richness of the contrast mechanisms and the flexibility in control of imaging parameters.

  7. Magnetic resonance 4D flow analysis of cerebrospinal fluid dynamics in Chiari I malformation with and without syringomyelia

    Energy Technology Data Exchange (ETDEWEB)

    Bunck, Alexander C. [University Hospital of Muenster, Department of Clinical Radiology, Muenster (Germany); University of Cologne, Department of Radiology, Cologne (Germany); Kroeger, Jan Robert; Juettner, Alena; Heindel, Walter; Schwindt, Wolfram; Niederstadt, Thomas [University Hospital of Muenster, Department of Clinical Radiology, Muenster (Germany); Brentrup, Angela [University Hospital of Muenster, Department of Neurosurgery, Muenster (Germany); Fiedler, Barbara [University Hospital of Muenster, Department of General Pediatrics, Muenster (Germany); Crelier, Gerard R. [ETH and University of Zurich, Institute for Biomedical Engineering, Zurich (Switzerland); Martin, Bryn A. [Ecole Polytechnique Federale de Lausanne, Laboratory of Hemodynamics and Cardiovascular Technology, School of Engineering, Interfaculty Institute of Bioengineering, Lausanne (Switzerland); Maintz, David [University Hospital of Muenster, Department of Clinical Radiology, Muenster (Germany); University Hospital of Cologne, Department of Radiology, Cologne (Germany)

    2012-09-15

    To analyse cerebrospinal fluid (CSF) hydrodynamics in patients with Chiari type I malformation (CM) with and without syringomyelia using 4D magnetic resonance (MR) phase contrast (PC) flow imaging. 4D-PC CSF flow data were acquired in 20 patients with CM (12 patients with presyrinx/syrinx). Characteristic 4D-CSF flow patterns were identified. Quantitative CSF flow parameters were assessed at the craniocervical junction and the cervical spinal canal and compared with healthy volunteers and between patients with and without syringomyelia. Compared with healthy volunteers, 17 CM patients showed flow abnormalities at the craniocervical junction in the form of heterogeneous flow (n = 3), anterolateral flow jets (n = 14) and flow vortex formation (n = 5), most prevalent in patients with syringomyelia. Peak flow velocities at the craniocervical junction were significantly increased in patients (-15.5 {+-} 11.3 vs. -4.7 {+-} 0.7 cm/s in healthy volunteers, P < 0.001). At the level of C1, maximum systolic flow was found to be significantly later in the cardiac cycle in patients (30.8 {+-} 10.3 vs. 22.7 {+-} 4.1%, P < 0.05). 4D-PC flow imaging allowed comprehensive analysis of CSF flow in patients with Chiari I malformation. Alterations of CSF hydrodynamics were most pronounced in patients with syringomyelia. (orig.)

  8. Numerical Simulation of Steady and Pulsatile Flow Through Vascular Stenoses and Comparisons with Experiments Using Phase Contrast Magnetic Resonance Imaging

    Science.gov (United States)

    Behrens, Geoffrey; Agarwal, Ramesh; Moghaddam, Abbas N.; Choi, Eric T.; Amini, Amir A.

    2003-11-01

    A commercially available numerical flow solver "FLUENT" is employed in simulation of blood flow through vascular stenoses. Fluid properties are set to match those of the blood mimicking fluid used in flow phantom experiments at the Washington University School of Medicine. Computational results are compared for steady flow through axisymmetric and three-dimensional phantoms modeling mild to severe stenonses with the data collected using Phase Contrast Magnetic Resonance Imaging (PC-MRI) technique by colleagues in the CVIA laboratory at Washington University School of Medicine. Computations are also performed for pulsatile flow through vascular stenoses. Comparisons of PC-MRI and FLUENT output data show qualitative agreement in streamline patterns and good quantitative agreement for pressure drop across the stenoses.

  9. Magnetic resonance imaging of slow water flow during infiltration and evaporation by tracer motion

    Science.gov (United States)

    Pohlmeier, A.; Haber-Pohlmeier, S.; Bechtold, M.; Vanderborght, J.; Vereecken, H.

    2012-04-01

    Water fluxes in soils control many processes in the environment like plant nutrition, solute and pollutant transport. In the last two decades non-invasive visualization methods have been adapted to monitor flux processes on the small scale. Magnetic resonance imaging (MRI), also well known from medical diagnostics, is one of the most versatile ones. It mostly probes directly the substance of interest: water, and it offers many opportunities to manipulate the observed signals for creating different contrasts and thus probing different properties of the porous medium and the embedded fluids. For example, one can make the signal sensitive to the total proton density, i. e. water content, to spatial distributions of relaxation times which reflect pore sizes, to spatial distributions of transport coefficients, and to concentration of contrast agents by using strongly T1 weighted MRI pulse sequences. In this presentation we use GdDTPA2- for monitoring flux processes in soil columns in an ultra-wide bore MRI scanner. It offers the opportunity for monitoring slow water fluxes mainly occurring in soil systems which are not monitorable with direct MRI flow imaging. This contrast agent is most convenient since it behaves conservatively, i.e. it does not sorb at different soil materials and it is chemically stable. Firstly, we show that its mode of action in natural porous media is identical to that known from medical applications as proved by the identical relaxivity parameters [1]. Secondly, the tracer is applied for the visualization of flux processes during evaporation-driven flow. Theoretical considerations by forward simulation predicted a lateral redistribution of solutes during evaporative upward fluxes from highly conductive fine material to neighbouring domains with low water content and conductivity. Here we could prove that such near-surface redistribution really takes place [2]. Thirdly, this tracer is applied for the investigation of water uptake by root systems

  10. Advances in magnetic resonance 8

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 8 describes the magnetic resonance in spin polarization and saturation transfer. This book discusses the theory of chemically induced dynamic spin polarization; basic results for the radical-pair mechanism; and optical spin polarization in molecular crystals. The theory of optical electronic polarization (OEP); NMR in flowing systems; and applications of NMR in a flowing liquid are also elaborated. This text likewise covers the saturation transfer spectroscopy; studies of spin labels in the intermediate and fast motion regions; and spin-density matrix and

  11. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses ... of the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical ...

  12. Absolute cerebral blood flow and blood volume measured by magnetic resonance imaging bolus tracking: comparison with positron emission tomography values

    DEFF Research Database (Denmark)

    Østergaard, Leif; Smith, D F; Vestergaard-Poulsen, Peter;

    1998-01-01

    The authors determined cerebral blood flow (CBF) with magnetic resonance imaging (MRI) of contrast agent bolus passage and compared the results with those obtained by O-15 labeled water (H215O) and positron emission tomography (PET). Six pigs were examined by MRI and PET under normo......- and hypercapnic conditions. After dose normalization and introduction of an empirical constant phi Gd, absolute regional CBF was calculated from MRI. The spatial resolution and the signal-to-noise ratio of CBF measurements by MRI were better than by the H215O-PET protocol. Magnetic resonance imaging cerebral...... blood volume (CBV) estimates obtained using this normalization constant correlated well with values obtained by O-15 labeled carbonmonooxide (C15O) PET. However, PET CBV values were approximately 2.5 times larger than absolute MRI CBV values, supporting the hypothesized sensitivity of MRI to small...

  13. Higher CHADS2 score is associated with impaired coronary flow reserve: A study using phase contrast cine magnetic resonance imaging.

    Science.gov (United States)

    Kirigaya, Hidekuni; Kato, Shingo; Gyotoku, Daiki; Yamada, Nao; Iinuma, Naoki; Kusakawa, Yuka; Iguchi, Kohei; Miki, Yuko; Nakachi, Tatsuya; Fukui, Kazuki; Iwasawa, Tae; Kimura, Kazuo

    2016-10-15

    The presence of coronary microvascular dysfunction (CMD) is an important prognostic marker for coronary artery disease (CAD) patients. The purpose of this study was to investigate whether the CHADS2 score is associated with CMD evaluated by magnetic resonance imaging (MRI). One hundred forty three patients with known or suspected CAD (mean age 70.3±9.5years) were enrolled. All patients did not have any significant coronary stenosis on X-ray coronary angiography (CAG) at the time of MRI acquisition. By using a 1.5T MRI scanner, breath-hold phase contrast cine MRI images of coronary sinus (CS) were obtained to assess the blood flow of CS both at rest and during adenosine triphosphate (ATP) infusion. Coronary flow reserve (CFR) was calculated as CS blood flow during ATP infusion divided by CS blood flow at rest. CMD was defined as CFRcine MRI. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. Magnetic Resonance Force Microscopy System

    Data.gov (United States)

    Federal Laboratory Consortium — The Magnetic Resonance Force Microscopy (MRFM) system, developed by ARL, is the world's most sensitive nuclear magnetic resonance (NMR) spectroscopic analysis tool,...

  15. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Magnetic Resonance, Functional (fMRI) - Brain Children's (Pediatric) CT (Computed Tomography) Magnetic Resonance Imaging (MRI) Safety Contrast Materials Children and Radiation ...

  16. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Magnetic Resonance, Functional (fMRI) - Brain Children's (Pediatric) CT (Computed Tomography) Magnetic Resonance Imaging (MRI) Safety Contrast Materials Children and Radiation Safety ...

  17. Three-Directional Evaluation of Mitral Flow in the Rat Heart by Phase-Contrast Cardiovascular Magnetic Resonance.

    Directory of Open Access Journals (Sweden)

    Kristine Skårdal

    Full Text Available Determination of mitral flow is an important aspect in assessment of cardiac function. Traditionally, mitral flow is measured by Doppler echocardiography which suffers from several challenges, particularly related to the direction and the spatial inhomogeneity of flow. These challenges are especially prominent in rodents. The purpose of this study was to establish a cardiovascular magnetic resonance (CMR protocol for evaluation of three-directional mitral flow in a rodent model of cardiac disease.Three-directional mitral flow were evaluated by phase contrast CMR (PC-CMR in rats with aortic banding (AB (N = 7 and sham-operated controls (N = 7. Peak mitral flow and deceleration rate from PC-CMR was compared to conventional Doppler echocardiography. The accuracy of PC-CMR was investigated by comparison of spatiotemporally integrated mitral flow with left ventricular stroke volume assessed by cine CMR.PC-CMR portrayed the spatial distribution of mitral flow and flow direction in the atrioventricular plane throughout diastole. Both PC-CMR and echocardiography demonstrated increased peak mitral flow velocity and higher deceleration rate in AB compared to sham. Comparison with cine CMR revealed that PC-CMR measured mitral flow with excellent accuracy. Echocardiography presented significantly lower values of flow compared to PC-CMR.For the first time, we show that PC-CMR offers accurate evaluation of three-directional mitral blood flow in rodents. The method successfully detects alterations in the mitral flow pattern in response to cardiac disease and provides novel insight into the characteristics of mitral flow.

  18. Magnetic Resonance Sensors

    Directory of Open Access Journals (Sweden)

    Robert H. Morris

    2014-11-01

    Full Text Available Magnetic Resonance finds countless applications, from spectroscopy to imaging, routinely in almost all research and medical institutions across the globe. It is also becoming more frequently used for specific applications in which the whole instrument and system is designed for a dedicated application. With beginnings in borehole logging for the petro-chemical industry Magnetic Resonance sensors have been applied to fields as varied as online process monitoring for food manufacture and medical point of care diagnostics. This great diversity is seeing exciting developments in magnetic resonance sensing technology published in application specific journals where they are often not seen by the wider sensor community. It is clear that there is enormous interest in magnetic resonance sensors which represents a significant growth area. The aim of this special edition of Sensors was to address the wide distribution of relevant articles by providing a forum to disseminate cutting edge research in this field in a single open source publication.[...

  19. Coronary artery flow measurement using navigator echo gated phase contrast magnetic resonance velocity mapping at 3.0 T.

    Science.gov (United States)

    Johnson, Kevin; Sharma, Puneet; Oshinski, John

    2008-01-01

    A validation study and early results for non-invasive, in vivo measurement of coronary artery blood flow using phase contrast magnetic resonance imaging (PC-MRI) at 3.0T is presented. Accuracy of coronary artery blood flow measurements by phase contrast MRI is limited by heart and respiratory motion as well as the small size of the coronary arteries. In this study, a navigator echo gated, cine phase velocity mapping technique is described to obtain time-resolved velocity and flow waveforms of small diameter vessels at 3.0T. Phantom experiments using steady, laminar flow are presented to validate the technique and show flow rates measured by 3.0T phase contrast MRI to be accurate within 15% of true flow rates. Subsequently, in vivo scans on healthy volunteers yield velocity measurements for blood flow in the right, left anterior descending, and left circumflex arteries. Measurements of average, cross-sectional velocity were obtainable in 224/243 (92%) of the cardiac phases. Time-averaged, cross-sectional velocity of the blood flow was 6.8+/-4.3cm/s in the LAD, 8.0+/-3.8cm/s in the LCX, and 6.0+/-1.6cm/s in the RCA.

  20. Flow Characterization of Severe Carotid Artery Stenosis in Pre- and Post-operative Phantoms by Using Magnetic Resonance Velocimetry

    Science.gov (United States)

    Ko, Seungbin; Song, Simon; Kim, Doosang

    2016-11-01

    It is remained unknown that the flow characteristics changes between pre- and post-operative severe carotid artery stenosis could affect the long-term patency or failure. However, in-vivo clinical experiments to uncover the flow details are far from bed-side due to limited measurement resolutions, blurring artifact, etc. We studied detailed flow characteristics of more than 75% severe carotid artery stenosis before and after surgical treatments. Real-size flow phantoms for 10 patients, who underwent carotid endarterectomy with patch/no patch closure, were prepared by using a 3D rapid-prototype machine from CT scanned images. The working fluid is a glycerin aqueous solution, and patient-specific pulsatile flows were applied to the phantoms, based on ultrasonic flow rate measurements. The flows were visualized with magnetic resonance velocimetry (MRV). The detailed flow characteristics are presented for both pre- and post-operative carotid arteries along with visualization data of 3 dimensional, 3 component velocity fields. This work was supported by the National Research Foundation of Korea (NRF) Grant funded by the Korea government (MSIP) (No. 2016R1A2B3009541).

  1. Visualization of periventricular collaterals in moyamoya disease with flow-sensitive black-blood magnetic resonance angiography: preliminary experience.

    Science.gov (United States)

    Funaki, Takeshi; Fushimi, Yasutaka; Takahashi, Jun C; Takagi, Yasushi; Araki, Yoshio; Yoshida, Kazumichi; Kikuchi, Takayuki; Miyamoto, Susumu

    2015-01-01

    Fragile abnormal collaterals in moyamoya disease, known as "moyamoya vessels," have rarely been defined. While flow-sensitive black-blood magnetic resonance angiography (FSBB-MRA) is a promising technique for visualizing perforating arteries, as of this writing no other reports exist regarding its application to moyamoya disease. Six adults with moyamoya disease underwent FSBB-MRA. It depicted abnormal collaterals as extended lenticulostriate, thalamic perforating, or choroidal arteries, which were all connected to the medullary or insular artery in the periventricular area and supplied the cortex. This preliminary case series illustrates the potential for FSBB-MRA to reveal abnormal moyamoya vessels, which could be reasonably defined as periventricular collaterals.

  2. Evaluation of flow volume and flow patterns in the patent false lumen of chronic aortic dissections using velocity-encoded cine magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Toshihisa; Watanabe, Shigeru; Sakurada, Hideki; Ono, Katsuhiro; Urano, Miharu; Hijikata, Yasuyoshi; Saito, Isao; Masuda, Yoshiaki [Chiba Univ. (Japan). School of Medicine

    2000-10-01

    In 21 patients with chronic aortic dissections and proven patent false lumens, the flow volume and flow patterns in the patent false lumens was evaluated using velocity-encoded cine magnetic resonance imaging (VENC-MRI) and the relationship between the flow characteristics and aortic enlargement was retrospectively examined. Flow patterns in the false lumen were divided into 3 groups: pattern A with primarily antegrade flow (n=6), pattern R with primarily retrograde flow (n=3), and pattern B with bidirectional flow (n=12). In group A, the rate of flow volume in the false lumen compared to the total flow volume in true and false lumens (%TFV) and the average rate of enlargement of the maximum diameter of the dissected aorta per year ({delta}D) were significantly greater than in groups R and B (%TFV: 74.1{+-}0.07 vs 15.2{+-}0.03 vs 11.8{+-}0.04, p<0.01; {delta}D: 3.62{+-}0.82 vs 0 vs 0.58{+-}0.15 mm/year, p<0.05, respectively). There was a significant correlation between %TFV and {delta}D (r=0.79, p<0.0001). Evaluation of flow volume and flow patterns in the patent false lumen using VENC-MRI may be useful for predicting enlargement of the dissected aorta. (author)

  3. Information flow and protein dynamics: the interplay between nuclear magnetic resonance spectroscopy and molecular dynamics simulations

    Science.gov (United States)

    Pastor, Nina; Amero, Carlos

    2015-01-01

    Proteins participate in information pathways in cells, both as links in the chain of signals, and as the ultimate effectors. Upon ligand binding, proteins undergo conformation and motion changes, which can be sensed by the following link in the chain of information. Nuclear magnetic resonance (NMR) spectroscopy and molecular dynamics (MD) simulations represent powerful tools for examining the time-dependent function of biological molecules. The recent advances in NMR and the availability of faster computers have opened the door to more detailed analyses of structure, dynamics, and interactions. Here we briefly describe the recent applications that allow NMR spectroscopy and MD simulations to offer unique insight into the basic motions that underlie information transfer within and between cells. PMID:25999971

  4. Information Flow and Protein Dynamics: the Interplay Between Nuclear Magnetic Resonance Spectroscopy and Molecular Dynamics Simulations

    Directory of Open Access Journals (Sweden)

    Nina ePastor

    2015-05-01

    Full Text Available Proteins participate in information pathways in cells, both as links in the chain of signals, and as the ultimate effectors. Upon ligand binding, proteins undergo conformation and motion changes, which can be sensed by the following link in the chain of information. Nuclear magnetic resonance (NMR spectroscopy and molecular dynamics (MD simulations represent powerful tools for examining the time-dependent function of biological molecules. The recent advances in NMR and the availability of faster computers have opened the door to more detailed analyses of structure, dynamics and interactions. Here we briefly describe the recent applications that allow NMR spectroscopy and MD simulations to offer unique insight into the basic motions that underlie information transfer within and between cells.

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... Us News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging ( ... if possible, or removed prior to the MRI scan. Because they can interfere with the magnetic field ...

  6. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) uses a powerful magnetic field, radio waves ...

  7. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) uses a powerful magnetic field, radio ...

  8. Magnetic resonance imaging flow void changes after cerebrospinal fluid shunt in post-traumatic hydrocephalus: clinical correlations and outcome.

    Science.gov (United States)

    Missori, Paolo; Miscusi, Massimo; Formisano, Rita; Peschillo, Simone; Polli, Filippo M; Melone, Antonio; Martini, Stefano; Paolini, Sergio; Delfini, Roberto

    2006-07-01

    The assessment of the flow-void in the cerebral aqueduct of patients with post-traumatic hydrocephalus on magnetic resonance imaging (MRI) evaluation could concur the right diagnosis and have a prognostic value. We analysed prospectively 28 patients after a severe head injury (GCSflow-void signal in the cerebral acqueduct on T2-weighted and proton density MRI. Twenty-two patients were shunted (n=19) or revised (n=3). Six patients were followed-up without surgery. Twenty out of 22 shunted patients (91%) showed variable reduction of the fast flow-void. Eighteen of the operated patients (82%) presented a significant clinical improvement at 6-month follow-up. All patients (n=2) who had no change of the fast flow-void after surgery did not clinically improve. The six non-shunted patients did not present any clinical or radiological improvement. In head-injured patients, fast flow-void in the cerebral aqueduct is diagnostic for post-traumatic hydrocephalus and its reduction after ventriculo-peritoneal shunt is correlated with a neurological improvement. In already shunted patients, a persistent fast flow-void is associated with a lack of or very slow clinical improvement and it should be considered indicative of under-drainage.

  9. Nuclear magnetic resonance characterization of the stationary dynamics of partially saturated media during steady-state infiltration flow

    Science.gov (United States)

    Rassi, Erik M.; Codd, Sarah L.; Seymour, Joseph D.

    2011-01-01

    Flow in porous media and the resultant hydrodynamics are important in fields including but not limited to the hydrology, chemical, medical and petroleum industries. The observation and understanding of the hydrodynamics in porous media are critical to the design and optimal utilization of porous media, such as those seen in trickle-bed reactors, medical filters, subsurface flows and carbon sequestration. Magnetic resonance (MR) provides for a non-invasive technique that can probe the hydrodynamics on pore and bulk scale lengths; many previous works have characterized fully saturated porous media, while rapid MR imaging (MRI) methods in particular have previously been applied to partially saturated flows. We present time- and ensemble-averaged MR measurements to observe the effects on a bead pack partially saturated with air under flowing water conditions. The 10 mm internal diameter bead pack was filled with 100 μm borosilicate glass beads. Air was injected into the bead pack as water flowed simultaneously through the sample at 25 ml h-1. The initial partially saturated state was characterized with MRI density maps, free induction decay (FID) experiments, propagators and velocity maps before the water flow rate was increased incrementally from 25 to 500 ml h-1. After the maximum flow rate of 500 ml h-1, the MRI density maps, FID experiments, propagators and velocity maps were repeated and compared to the data taken before the maximum flow rate. This work shows that a partially saturated single-phase flow has global flow dynamics that return to characteristic flow statistics once a steady-state high flow rate has been reached. This high flow rate pushed out a significant amount of the air in the bead pack and caused the return of a preferential flow pattern. Velocity maps indicated that local flow statistics were not the same for the before and after blow out conditions. It has been suggested and shown previously that a flow pattern can return to

  10. Suitable image parameters and analytical method for quantitatively measuring cerebral blood flow volume with phase-contrast magnetic resonance imaging.

    Directory of Open Access Journals (Sweden)

    Handa H

    1999-02-01

    Full Text Available The aim of this study was to determine suitable image parameters and an analytical method for phase-contrast magnetic resonance imaging (PC-MRI as a means of measuring cerebral blood flow volume. This was done by constructing an experimental model and applying the results to a clinical application. The experimental model was constructed from the aorta of a bull and circulating isotonic saline. The image parameters of PC-MRI (repetition time, flip angle, matrix, velocity rate encoding, and the use of square pixels were studied with percent flow volume (the ratio of actual flow volume to measured flow volume. The most suitable image parameters for accurate blood flow measurement were as follows: repetition time, 50 msec; flip angle, 20 degrees; and a 512 x 256 matrix without square pixels. Furthermore, velocity rate encoding should be set ranging from the maximum flow velocity in the vessel to five times this value. The correction in measuring blood flow was done with the intensity of the region of interest established in the background. With these parameters for PC-MRI, percent flow volume was greater than 90%. Using the image parameters for PC-MRI and the analytical method described above, we evaluated cerebral blood flow volume in 12 patients with occlusive disease of the major cervical arteries. The results were compared with conventional xenon computed tomography. The values found with both methods showed good correlation. Thus, we concluded that PC-MRI was a noninvasive method for evaluating cerebral blood flow in patients with occlusive disease of the major cervical arteries.

  11. Measurement of aortic blood flow by magnetic resonance below and above the origin of the coronary arteries in postmenopausal hormone replacement therapy

    DEFF Research Database (Denmark)

    Sørensen, Morten Beck; Fritz-Hansen, Thomas; Jensen, Henrik Halvor

    2004-01-01

    PURPOSE: Principal blood flow measures might be assessable by velocity-encoded cine magnetic resonance (VENC MR) of aortic blood flow. The feasibility of using VENC MR for clinical research was tested in a contemporary and controversial human model: the effects of 17beta-estradiol (E) and cyclic...

  12. Computational Diffusion Magnetic Resonance Imaging Based on Time-Dependent Bloch NMR Flow Equation and Bessel Functions.

    Science.gov (United States)

    Awojoyogbe, Bamidele O; Dada, Michael O; Onwu, Samuel O; Ige, Taofeeq A; Akinwande, Ninuola I

    2016-04-01

    Magnetic resonance imaging (MRI) uses a powerful magnetic field along with radio waves and a computer to produce highly detailed "slice-by-slice" pictures of virtually all internal structures of matter. The results enable physicians to examine parts of the body in minute detail and identify diseases in ways that are not possible with other techniques. For example, MRI is one of the few imaging tools that can see through bones, making it an excellent tool for examining the brain and other soft tissues. Pulsed-field gradient experiments provide a straightforward means of obtaining information on the translational motion of nuclear spins. However, the interpretation of the data is complicated by the effects of restricting geometries as in the case of most cancerous tissues and the mathematical concept required to account for this becomes very difficult. Most diffusion magnetic resonance techniques are based on the Stejskal-Tanner formulation usually derived from the Bloch-Torrey partial differential equation by including additional terms to accommodate the diffusion effect. Despite the early success of this technique, it has been shown that it has important limitations, the most of which occurs when there is orientation heterogeneity of the fibers in the voxel of interest (VOI). Overcoming this difficulty requires the specification of diffusion coefficients as function of spatial coordinate(s) and such a phenomenon is an indication of non-uniform compartmental conditions which can be analyzed accurately by solving the time-dependent Bloch NMR flow equation analytically. In this study, a mathematical formulation of magnetic resonance flow sequence in restricted geometry is developed based on a general second order partial differential equation derived directly from the fundamental Bloch NMR flow equations. The NMR signal is obtained completely in terms of NMR experimental parameters. The process is described based on Bessel functions and properties that can make it

  13. Advances in magnetic resonance 10

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 10, presents a variety of contributions to the theory and practice of magnetic resonance. The book contains three chapters that examine superoperators in magnetic resonance; ultrasonically modulated paramagnetic resonance; and the utility of electron paramagnetic resonance (EPR) and electron-nuclear double-resonance (ENDOR) techniques for studying low-frequency modes of atomic fluctuations and their significance for understanding the mechanism of structural phase transitions in solids.

  14. Myocardial blood flow quantification for evaluation of coronary artery disease by positron emission tomography, cardiac magnetic resonance imaging, and computed tomography.

    Science.gov (United States)

    Waller, Alfonso H; Blankstein, Ron; Kwong, Raymond Y; Di Carli, Marcelo F

    2014-05-01

    The noninvasive detection of the presence and functional significance of coronary artery stenosis is important in the diagnosis, risk assessment, and management of patients with known or suspected coronary artery disease. Quantitative assessment of myocardial perfusion can provide an objective and reproducible estimate of myocardial ischemia and risk prediction. Positron emission tomography, cardiac magnetic resonance, and cardiac computed tomography perfusion are modalities capable of measuring myocardial blood flow and coronary flow reserve. In this review, we will discuss the technical aspects of quantitative myocardial perfusion imaging with positron emission tomography, cardiac magnetic resonance imaging, and computed tomography, and its emerging clinical applications.

  15. Inflow hemodynamics evaluated by using four-dimensional flow magnetic resonance imaging and the size ratio of unruptured cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Futami, Kazuya [Matto-Ishikawa Central Hospital, Department of Neurosurgery, Hakusan, Ishikawa (Japan); Nambu, Iku; Kitabayashi, Tomohiro; Sano, Hiroki; Misaki, Kouichi; Uchiyama, Naoyuki; Nakada, Mitsutoshi [Kanazawa University School of Medicine, Department of Neurosurgery, Kanazawa, Ishikawa (Japan)

    2017-04-15

    Prediction of the rupture risk is critical for the identification of unruptured cerebral aneurysms (UCAs) eligible for invasive treatments. The size ratio (SR) is a strong morphological predictor for rupture. We investigated the relationship between the inflow hemodynamics evaluated on four-dimensional (4D) flow magnetic resonance (MR) imaging and the SR to identify specific characteristics related to UCA rupture. We evaluated the inflow jet patterns and inflow hemodynamic parameters of 70 UCAs on 4D flow MR imaging and compared them among 23 aneurysms with an SR ≥2.1 and 47 aneurysms with an SR ≤2.0. Based on the shape of inflow streamline bundles with a velocity ≥75% of the maximum flow velocity in the parent artery, the inflow jet patterns were classified as concentrated (C), diffuse (D), neck-limited (N), and unvisualized (U). The incidence of patterns C and N was significantly higher in aneurysms with an SR ≥2.1. The rate of pattern U was significantly higher in aneurysms with an SR ≤2.0. The maximum inflow rate and the inflow rate ratio were significantly higher in aneurysms with an SR ≥2.1. The SR affected the inflow jet pattern, the maximum inflow rate, and the inflow rate ratio of UCAs. In conjunction with the SR, inflow hemodynamic analysis using 4D flow MR imaging may contribute to the risk stratification for aneurysmal rupture. (orig.)

  16. Comparative imaging of differential pulmonary blood flow in patients with congenital heart disease: magnetic resonance imaging versus lung perfusion scintigraphy.

    Science.gov (United States)

    Roman, Kevin S; Kellenberger, Christian J; Farooq, Saqba; MacGowan, Christopher K; Gilday, David L; Yoo, Shi-Joon

    2005-03-01

    Lung perfusion scintigraphy is considered the gold standard to assess differential pulmonary blood flow while magnetic resonance (MR) has been shown to be an accurate alternative in some studies. The purpose of the study was to assess the accuracy of phase contrast magnetic resonance (PC-MR) in measuring pulmonary blood flow ratio compared with lung perfusion scintigraphy in patients with complex pulmonary artery anatomy or pulmonary hypertension and to document reasons for discrepant results. We identified 25 cases of congenital heart disease between January 2000 and 2003, in whom both techniques of assessing pulmonary blood flow were performed within a 6-month period without an interim surgical or transcatheter intervention. The study group included cases with branch pulmonary artery stenosis, intracardiac shunts, single ventricle circulation, pulmonary venous anomalies and conotruncal defects. The mean age at study was 5.7 years (range 0.33-12) with a mean weight of 20.3 kg (range 6.5-53.6). The two methods were compared using a Bland-Altman analysis, and the Pearson correlation coefficient was calculated using the lung scan as the gold standard. Discrepant results were examined by reviewing the source images to elucidate reasons for error by MR. Bland-Altman analysis comparing right pulmonary artery (RPA) blood flow percentage, as measured by each modality, showed a mean difference of 1.43+/-9.8 (95% limits of agreement: -17.8, 20.6) with a correlation coefficient of r=0.84, P10%) was found with a mean difference between techniques of 17.9%. The reasons for discrepant results included MR artifacts, dephasing owing to turbulent flow, site of data acquisition and lobar lung collapse. When using PC-MR to assess pulmonary blood flow ratio, important technical errors occur in a significant proportion of patients who have abnormal pulmonary artery anatomy or pulmonary hypertension. If these technical errors are avoided, PC-MR is able to supply both anatomic and

  17. Comparative imaging of differential pulmonary blood flow in patients with congenital heart disease: magnetic resonance imaging versus lung perfusion scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Roman, Kevin S. [Hospital for Sick Children, Department of Cardiology, Toronto, ON (Canada); Kellenberger, Christian J.; Farooq, Saqba; MacGowan, Christopher K.; Gilday, David L.; Yoo, Shi-Joon [Hospital for Sick Children, Diagnostic Imaging and Radiology, Toronto, ON (Canada)

    2005-03-01

    Lung perfusion scintigraphy is considered the gold standard to assess differential pulmonary blood flow while magnetic resonance (MR) has been shown to be an accurate alternative in some studies. The purpose of the study was to assess the accuracy of phase contrast magnetic resonance (PC-MR) in measuring pulmonary blood flow ratio compared with lung perfusion scintigraphy in patients with complex pulmonary artery anatomy or pulmonary hypertension and to document reasons for discrepant results. We identified 25 cases of congenital heart disease between January 2000 and 2003, in whom both techniques of assessing pulmonary blood flow were performed within a 6-month period without an interim surgical or transcatheter intervention. The study group included cases with branch pulmonary artery stenosis, intracardiac shunts, single ventricle circulation, pulmonary venous anomalies and conotruncal defects. The mean age at study was 5.7 years (range 0.33-12) with a mean weight of 20.3 kg (range 6.5-53.6). The two methods were compared using a Bland-Altman analysis, and the Pearson correlation coefficient was calculated using the lung scan as the gold standard. Discrepant results were examined by reviewing the source images to elucidate reasons for error by MR. Bland-Altman analysis comparing right pulmonary artery (RPA) blood flow percentage, as measured by each modality, showed a mean difference of 1.43{+-}9.8 (95% limits of agreement: -17.8, 20.6) with a correlation coefficient of r=0.84, P<0.0001. In six (24%) cases a large difference (>10%) was found with a mean difference between techniques of 17.9%. The reasons for discrepant results included MR artifacts, dephasing owing to turbulent flow, site of data acquisition and lobar lung collapse. When using PC-MR to assess pulmonary blood flow ratio, important technical errors occur in a significant proportion of patients who have abnormal pulmonary artery anatomy or pulmonary hypertension. If these technical errors are

  18. Functional Magnetic Resonance Imaging

    Science.gov (United States)

    Voos, Avery; Pelphrey, Kevin

    2013-01-01

    Functional magnetic resonance imaging (fMRI), with its excellent spatial resolution and ability to visualize networks of neuroanatomical structures involved in complex information processing, has become the dominant technique for the study of brain function and its development. The accessibility of in-vivo pediatric brain-imaging techniques…

  19. Single spin magnetic resonance

    Science.gov (United States)

    Wrachtrup, Jörg; Finkler, Amit

    2016-08-01

    Different approaches have improved the sensitivity of either electron or nuclear magnetic resonance to the single spin level. For optical detection it has essentially become routine to observe a single electron spin or nuclear spin. Typically, the systems in use are carefully designed to allow for single spin detection and manipulation, and of those systems, diamond spin defects rank very high, being so robust that they can be addressed, read out and coherently controlled even under ambient conditions and in a versatile set of nanostructures. This renders them as a new type of sensor, which has been shown to detect single electron and nuclear spins among other quantities like force, pressure and temperature. Adapting pulse sequences from classic NMR and EPR, and combined with high resolution optical microscopy, proximity to the target sample and nanoscale size, the diamond sensors have the potential to constitute a new class of magnetic resonance detectors with single spin sensitivity. As diamond sensors can be operated under ambient conditions, they offer potential application across a multitude of disciplines. Here we review the different existing techniques for magnetic resonance, with a focus on diamond defect spin sensors, showing their potential as versatile sensors for ultra-sensitive magnetic resonance with nanoscale spatial resolution.

  20. Functional Magnetic Resonance Imaging

    Science.gov (United States)

    Voos, Avery; Pelphrey, Kevin

    2013-01-01

    Functional magnetic resonance imaging (fMRI), with its excellent spatial resolution and ability to visualize networks of neuroanatomical structures involved in complex information processing, has become the dominant technique for the study of brain function and its development. The accessibility of in-vivo pediatric brain-imaging techniques…

  1. Cerebral blood flow and cerebrovascular reserve capacity: estimation by dynamic magnetic resonance imaging.

    Science.gov (United States)

    Schreiber, W G; Gückel, F; Stritzke, P; Schmiedek, P; Schwartz, A; Brix, G

    1998-10-01

    We have developed a new method for estimation of regional CBF (rCBF) and cerebrovascular reserve capacity on a pixel-by-pixel basis by means of dynamic magnetic resonance imaging (MRI). Thirteen healthy volunteers, 8 patients with occlusion and/or high grade stenosis of the internal carotid artery (ICA), and 2 patients with acute stroke underwent dynamic susceptibility-weighted contrast enhanced MRI. Using principles of indicator dilution theory and deconvolution analysis, maps of rCBF, regional cerebral blood volume, and of the mean transit time (MTT) were calculated. In patients with ICA occlusion/stenosis, cerebrovascular reserve capacity was assessed by the rCBF increase after acetazolamide stimulation. Mean gray and white matter rCBF values in normals were 67.1 and 23.7 mL x 100 g(-1) x min(-1), respectively. Before acetazolamide stimulation, six of eight patients with ICA occlusions showed decreased rCBF values; and in seven patients increased MTT values were observed in tissue ipsilateral to the occlusion. After acetazolamide stimulation, decreased cerebrovascular reserve capacity was observed in five of eight patients with ICA occlusion. In acute stroke, rCBF in the central core of ischemia was less than 8 mL x 100 g(-1) x min(-1). In peri-infarct tissue, rCBF and MTT were higher than in unaffected tissue but rCBF was normal. Dynamic MRI provides important clinical information on the hemodynamic state of brain tissue in patients with occlusive cerebrovascular disease or acute stroke.

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... content. Related Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... The teddy bear denotes child-specific content. Related Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging (MRI) ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... to remain perfectly still and follow breath-holding instructions while the images are being recorded. If you ... Images related to Magnetic Resonance Imaging (MRI) - Head Videos related to Magnetic Resonance Imaging (MRI) - Head Sponsored ...

  5. Magnetic resonance of phase transitions

    CERN Document Server

    Owens, Frank J; Farach, Horacio A

    1979-01-01

    Magnetic Resonance of Phase Transitions shows how the effects of phase transitions are manifested in the magnetic resonance data. The book discusses the basic concepts of structural phase and magnetic resonance; various types of magnetic resonances and their underlying principles; and the radiofrequency methods of nuclear magnetic resonance. The text also describes quadrupole methods; the microwave technique of electron spin resonance; and the Mössbauer effect. Phase transitions in various systems such as fluids, liquid crystals, and crystals, including paramagnets and ferroelectrics, are also

  6. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) uses a powerful ... of Children’s (Pediatric) MRI? What is Children’s (Pediatric) MRI? Magnetic resonance imaging (MRI) is a noninvasive medical ...

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head ... limitations of MRI of the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is ...

  8. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging ( ... the limitations of Children’s (Pediatric) MRI? What is Children’s (Pediatric) MRI? Magnetic resonance imaging (MRI) is a ...

  9. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) ... limitations of Children’s (Pediatric) MRI? What is Children’s (Pediatric) MRI? Magnetic resonance imaging (MRI) is a noninvasive ...

  10. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  11. Quantification of left and right atrial kinetic energy using four-dimensional intracardiac magnetic resonance imaging flow measurements.

    Science.gov (United States)

    Arvidsson, Per M; Töger, Johannes; Heiberg, Einar; Carlsson, Marcus; Arheden, Håkan

    2013-05-15

    Kinetic energy (KE) of atrial blood has been postulated as a possible contributor to ventricular filling. Therefore, we aimed to quantify the left (LA) and right (RA) atrial blood KE using cardiac magnetic resonance (CMR). Fifteen healthy volunteers underwent CMR at 3 T, including a four-dimensional phase-contrast flow sequence. Mean LA KE was lower than RA KE (1.1 ± 0.1 vs. 1.7 ± 0.1 mJ, P energy better than nonrotational flow did. The KE increase in early diastole was higher in the LA (P < 0.001). Systolic KE correlated with the combination of atrial volume and systolic velocity of the atrioventricular plane displacement (r(2) = 0.57 for LA and r(2) = 0.64 for RA). Early diastolic KE of the LA correlated with left ventricle (LV) mass (r(2) = 0.28), however, no such correlation was found in the right heart. This suggests that LA KE increases during early ventricular diastole due to LV elastic recoil, indicating that LV filling is dependent on diastolic suction. Right ventricle (RV) relaxation does not seem to contribute to atrial KE. Instead, RA KE generated during ventricular systole may be conserved in a hydraulic "flywheel" and transferred to the RV through helical flow, which may contribute to RV filling.

  12. Long term evaluation of brain perfusion with magnetic resonance in high flow extracranial-intracranial saphenous graft bypass

    Energy Technology Data Exchange (ETDEWEB)

    Bozzao, Alessandro [University of Rome La Sapienza, Department of Neuroradiology, II Faculty of Medicine, Rome (Italy); Sant' Andrea Hospital, Rome (Italy); Fasoli, Fabrizio; Finocchi, Vanina; Romano, Andrea; Fantozzi, Luigi M. [University of Rome La Sapienza, Department of Neuroradiology, II Faculty of Medicine, Rome (Italy); Santoro, Giuseppe [University of Rome La Sapienza, Department of Neurosurgery, I Faculty of Medicine, Rome (Italy)

    2007-01-15

    Assessment was made of the cerebral vascular haemodynamic parameters in patients with a high-flow extra-intracranial (EC-IC) bypass performed for therapeutic occlusion of the internal carotid artery (ICA). Sixteen patients with ICA occlusion and EC-IC bypass (time interval from surgery 1-6 years) underwent MRI. Perfusion-weighted magnetic resonance imaging (PW-MRI) sequences were performed without the use of an arterial input function. The relative cerebral blood volume (rCBV), mean transit time (MTT) and relative cerebral blood flow (rCBF) were evaluated in all patients at the level of the basal ganglia, centrum semiovale and cortex in both hemispheres. Statistically significant differences (P<0.005) were observed in the haemodynamic parameters, indicating increased rCBV in the basal ganglia and decreased rCBF and rCBV in the cortex of the hemisphere supplied by the graft with respect to the contralateral. Patients with occlusion of the ICA and high flow EC-IC bypass do have altered vascular haemodynamic status between the hemispheres. In particular, rCBF is impaired in the surgical hemisphere at the level of the cortex. These patients should be followed-up to rule out chronic ischemia. (orig.)

  13. Parallel Magnetic Resonance Imaging

    CERN Document Server

    Uecker, Martin

    2015-01-01

    The main disadvantage of Magnetic Resonance Imaging (MRI) are its long scan times and, in consequence, its sensitivity to motion. Exploiting the complementary information from multiple receive coils, parallel imaging is able to recover images from under-sampled k-space data and to accelerate the measurement. Because parallel magnetic resonance imaging can be used to accelerate basically any imaging sequence it has many important applications. Parallel imaging brought a fundamental shift in image reconstruction: Image reconstruction changed from a simple direct Fourier transform to the solution of an ill-conditioned inverse problem. This work gives an overview of image reconstruction from the perspective of inverse problems. After introducing basic concepts such as regularization, discretization, and iterative reconstruction, advanced topics are discussed including algorithms for auto-calibration, the connection to approximation theory, and the combination with compressed sensing.

  14. Magnetic resonance velocity mapping of 3D cerebrospinal fluid flow dynamics in hydrocephalus: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Stadlbauer, Andreas [Landesklinikum St. Poelten, MR Physics Group, Department of Radiology, St. Poelten (Austria); University of Erlangen-Nuremberg, Department of Neurosurgery, Erlangen (Germany); Salomonowitz, Erich [Landesklinikum St. Poelten, MR Physics Group, Department of Radiology, St. Poelten (Austria); Brenneis, Christian [Landesklinikum St. Poelten, Department of Neurology, St. Poelten (Austria); Ungersboeck, Karl [Landesklinikum St. Poelten, Department of Neurosurgery, St. Poelten (Austria); Riet, Wilma van der [European MRI Consultancy (EMRIC), Strasbourg (France); Buchfelder, Michael; Ganslandt, Oliver [University of Erlangen-Nuremberg, Department of Neurosurgery, Erlangen (Germany)

    2012-01-15

    To investigate the detectability of CSF flow alterations in the ventricular system of patients with hydrocephalus using time-resolved 3D MR velocity mapping. MR velocity mapping was performed in 21 consecutive hydrocephalus patients and 21 age-matched volunteers using a 3D phase-contrast (PC) sequence. Velocity vectors and particle path lines were calculated for visualisation of flow dynamics. CSF flow was classified as ''hypomotile flow'' if it showed attenuated dynamics and as ''hypermotile flow'' if it showed increased dynamics compared with volunteers. Diagnostic efficacy was compared with routine 2D cine PC-MRI. Seven patients showed hypomotile CSF flow: six had non-communicating hydrocephalus due to aqueductal stenosis. One showed oscillating flow between the lateral ventricles after craniotomy for intracranial haemorrhage. Seven patients showed normal flow: six had hydrocephalus ex vacuo due to brain atrophy. One patient who underwent ventriculostomy 10 years ago showed a flow path through the opening. Seven patients showed hypermotile flow: three had normal pressure hydrocephalus, three had dementia, and in one the diagnosis remained unclear. The diagnostic efficacy of velocity mapping was significantly higher except for that of aqueductal stenosis. Our approach may be useful for diagnosis, therapy planning, and follow-up of different kinds of hydrocephalus. (orig.)

  15. Stress Perfusion Coronary Flow Reserve Versus Cardiac Magnetic Resonance for Known or Suspected CAD.

    Science.gov (United States)

    Kato, Shingo; Saito, Naka; Nakachi, Tatsuya; Fukui, Kazuki; Iwasawa, Tae; Taguri, Masataka; Kosuge, Masami; Kimura, Kazuo

    2017-08-15

    Phase-contrast (PC) cine magnetic resonance imaging (MRI) of the coronary sinus is a noninvasive method to quantify coronary flow reserve (CFR). This study sought to compare the prognostic value of CFR by cardiac magnetic resonance (CMR) and stress perfusion CMR to predict major adverse cardiac events (MACE). Participants included 276 patients with known coronary artery disease (CAD) and 400 with suspected CAD. CFR was calculated as myocardial blood flow during adenosine triphosphate infusion divided by myocardial blood flow at rest using PC cine MRI of the coronary sinus. During a median follow-up of 2.3 years, 47 patients (7%) experienced MACE. Impaired CFR (10% ischemia on stress perfusion CMR were significantly associated with MACE in patients with known CAD (hazard ratio [HR]: 5.17 and HR: 5.10, respectively) and suspected CAD (HR: 14.16 and HR: 6.50, respectively). The area under the curve for predicting MACE was 0.773 for CFR and 0.731 for stress perfusion CMR (p = 0.58) for patients with known CAD, and 0.885 for CFR and 0.776 for stress perfusion CMR (p = 0.059) in the group with suspected CAD. In patients with known CAD, sensitivity, specificity, and positive and negative predictive values to predict MACE were 64%, 91%, 38%, and 97%, respectively, for CFR, and 82%, 59%, 15%, and 97%, respectively, for stress perfusion CMR. In the suspected CAD group, these values were 65%, 99%, 80%, and 97%, respectively, for CFR, and 72%, 83%, 22%, and 98%, respectively, for stress perfusion CMR. The predictive values of CFR and stress perfusion CMR for MACE were comparable in patients with known CAD. In patients with suspected CAD, CFR showed higher HRs and areas under the curve than stress perfusion CMR, suggesting that CFR assessment by PC cine MRI might provide better risk stratification for patients with suspected CAD. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  16. Relationship between coronary flow reserve evaluated by phase-contrast cine cardiovascular magnetic resonance and serum eicosapentaenoic acid

    Science.gov (United States)

    2013-01-01

    Background Long-term intake of long-chain n-3 polyunsaturated fatty acids (n-3 PUFAs), especially eicosapentaenoic acid (EPA) is associated with a low risk for cardiovascular disease. Phase-contrast cine cardiovascular magnetic resonance (PC cine CMR) can assess coronary flow reserve (CFR). The present study investigates the relationship between CFR evaluated by PC cine CMR and the serum EPA. Methods We studied 127 patients (male, 116 (91%); mean age, 72.2 ± 7.4 years) with known or suspected coronary artery disease (CAD). X-ray coronary angiography revealed no significant coronary arterial stenoses (defined as luminal diameter reduction ≥50% on quantitative coronary angiogram (QCA) analysis) in all study participants. Breath-hold PC cine CMR images of the coronary sinus (CS) were acquired to assess blood flow of the CS both at rest and during adenosine triphosphate (ATP) infusion. We calculated CFR as CS blood flow during ATP infusion divided by that at rest. Patients were allocated to groups according to whether they had high (n = 64, EPA ≥ 75.8 μg/mL) or low (n = 63, EPA  2.5, which is the previously reported lower limit of normal flow reserve without obstructive CAD. Multivariate analysis revealed that EPA is an independent predictor of CFR > 2.5 (odds ratio, 1.01; 95% confidence interval, 1.00 – 1.02, p = 0.008). Conclusions The serum EPA is significantly correlated with CFR in CAD patients without significant coronary artery stenosis. PMID:24359564

  17. Dynamic Susceptibility Contrast Perfusion Magnetic Resonance Imaging Demonstrates Reduced Periventricular Cerebral Blood Flow in Dogs with Ventriculomegaly

    Directory of Open Access Journals (Sweden)

    Martin J. Schmidt

    2017-08-01

    Full Text Available The nature of ventriculomegaly in dogs is still a matter of debate. Signs of increased intraventricular pressure and atrophy of the cerebral white matter have been found in dogs with ventriculomegaly, which would imply increased intraventricular pressure and, therefore, a pathological condition, i.e., to some extent. Reduced periventricular blood flow was found in people with high elevated intraventricular pressure. The aim of this study was to compare periventricular brain perfusion in dogs with and without ventriculomegaly using perfusion weighted-magnetic-resonance-imaging to clarify as to whether ventriculomegaly might be associated with an increase in intraventricular pressure. Perfusion was measured in 32 Cavalier King Charles spaniels (CKCS with ventriculomegaly, 10 CKCSs were examined as a control group. Cerebral blood flow (CBF was measured using free-hand regions of interest (ROI in five brain regions: periventricular white matter, caudate nucleus, parietal cortex, hippocampus, and thalamus. CBF was significantly lower in the periventricular white matter of the dogs with ventriculomegaly (p = 0.0029 but not in the other ROIs. Reduction of periventricular CBF might imply increase of intraventricular pressure in ventriculomegaly.

  18. Understanding Aqueous Electrolyte Stability through Combined Computational and Magnetic Resonance Spectroscopy: A Case Study on Vanadium Redox Flow Battery Electrolytes

    Energy Technology Data Exchange (ETDEWEB)

    Vijayakumar, M.; Nie, Zimin; Walter, Eric D.; Hu, Jian Z.; Liu, Jun; Sprenkle, Vincent L.; Wang, Wei

    2015-02-01

    Redox flow battery (RFB) is a promising candidate for energy storage component in designing resilient grid scale power supply due to the advantage of the separation of power and energy. However, poorly understood chemical and thermal stability issues of electrolytes currently limit the performance of RFB. Designing of high performance stable electrolytes requires comprehensive knowledge about the molecular level solvation structure and dynamics of their redox active species. The molecular level understanding of detrimental V2O5 precipitation process led to successful designing of mixed acid based electrolytes for vanadium redox flow batteries (VRFB). The higher stability of mixed acid based electrolytes is attributed to the choice of hydrochloric acid as optimal co-solvent, which provides chloride anions for ligand exchange process in vanadium solvation structure. The role of chloride counter anion on solvation structure and dynamics of vanadium species were studied using combined magnetic resonance spectroscopy and DFT based theoretical methods. Finally, the solvation phenomenon of multiple vanadium species and their impact on VRFB electrolyte chemical stability were discussed.

  19. Magnetic resonance imaging 4-D flow-based analysis of aortic hemodynamics in Turner syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, Raoul [University Medical Center Heidelberg, Department of Congenital Heart Disease and Pediatric Cardiology, Heidelberg (Germany); Neu, Marie [University Medical Center, Department of Pediatric Hematology/Oncology/Hemostaseology, Mainz (Germany); Hirtler, Daniel [University of Freiburg, Department of Congenital Heart Defects and Pediatric Cardiology, Heart Center, Freiburg im Breisgau (Germany); Gimpel, Charlotte [Center for Pediatrics, Medical Center - University of Freiburg, Department of General Pediatrics, Adolescent Medicine and Neonatology, Freiburg im Breisgau (Germany); Markl, Michael [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Northwestern University, Department of Biomedical Engineering, McCormick School of Engineering, Chicago, IL (United States); Geiger, Julia [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); University Children' s Hospital, Department of Radiology, Zuerich (Switzerland)

    2017-04-15

    Cardiovascular surveillance is important in Turner syndrome because of the increased risk of aortic dilation and dissection with consecutively increased mortality. To compare 4-D flow MRI for the characterization of aortic 3-D flow patterns, dimensions and vessel wall parameters in pediatric patients with Turner syndrome and age-matched controls. We performed 4-D flow MRI measuring in vivo 3-D blood flow with coverage of the thoracic aorta in 25 patients with Turner syndrome and in 16 female healthy controls (age mean ± standard deviation were 16 ± 5 years and 17 ± 4 years, respectively). Blood flow was visualized by time-resolved 3-D path lines. Visual grading of aortic flow in terms of helices and vortices was performed by two independent observers. Quantitative analysis included measurement of aortic diameters, quantification of peak systolic wall shear stress, pulsatility index and oscillatory shear index at eight defined sites. Patients with Turner syndrome had significantly larger aortic diameters normalized to BSA, increased vortices in the ascending aorta and elevated helix flow in the ascending and descending aorta compared to controls (all P<0.03). Patients with abnormal helical or vortical flow in the ascending aorta had significantly larger diameters of the ascending aorta (P<0.03). Peak systolic wall shear stress, pulsatility index and oscillatory shear index were significantly lower in Turner patients compared to controls (p=0.02, p=0.002 and p=0.01 respectively). Four-dimensional flow MRI provides new insights into the altered aortic hemodynamics and wall shear stress that could have an impact on the development of aortic dissections. (orig.)

  20. Nuclear Magnetic Resonance Gyroscope

    Science.gov (United States)

    Larsen, Michael; Griffith, Robert; Bulatowicz, Michael

    2014-03-01

    The navigation grade micro Nuclear Magnetic Resonance Gyroscope (micro-NMRG) being developed by the Northrop Grumman Corporation (NGC) has concluded the fourth and final phase of the DARPA Navigation Grade Integrated Micro Gyro (NGIMG) program. Traditional MEMS gyros utilize springs as an inherent part of the sensing mechanism, leading to bias and scale factor sensitivity to acceleration and vibration. As a result, they have not met performance expectations in real world environments and to date have been limited to tactical grade applications. The Nuclear Magnetic Resonance Gyroscope (NMRG) utilizes the fixed precession rate of a nuclear spin in a constant magnetic field as an inertial reference for determining rotation. The nuclear spin precession rate sensitivity to acceleration and vibration is negligible for most applications. Therefore, the application of new micro and batch fabrication methods to NMRG technology holds great promise for navigation grade performance in a low cost and compact gyro. This presentation will describe the operational principles, design basics, and demonstrated performance of the NMRG including an overview of the NGC designs developed and demonstrated in the DARPA gyro development program.

  1. Direct numerical simulation of pore-scale flow in a bead pack: Comparison with magnetic resonance imaging observations

    Science.gov (United States)

    Yang, Xiaofan; Scheibe, Timothy D.; Richmond, Marshall C.; Perkins, William A.; Vogt, Sarah J.; Codd, Sarah L.; Seymour, Joseph D.; McKinley, Matthew I.

    2013-04-01

    A significant body of current research is aimed at developing methods for numerical simulation of flow and transport in porous media that explicitly resolve complex pore and solid geometries, and at utilizing such models to study the relationships between fundamental pore-scale processes and macroscopic manifestations at larger (i.e., Darcy) scales. A number of different numerical methods for pore-scale simulation have been developed, and have been extensively tested and validated for simplified geometries. However, validation of pore-scale simulations of fluid velocity for complex, three-dimensional (3D) pore geometries that are representative of natural porous media is challenging due to our limited ability to measure pore-scale velocity in such systems. Recent advances in magnetic resonance imaging (MRI) offer the opportunity to measure not only the pore geometry, but also local fluid velocities under steady-state flow conditions in 3D and with high spatial resolution. In this paper, we present a 3D velocity field measured at sub-pore resolution (tens of micrometers) over a centimeter-scale 3D domain using MRI methods. We have utilized the measured pore geometry to perform 3D simulations of Navier-Stokes flow over the same domain using direct numerical simulation techniques. We present a comparison of the numerical simulation results with the measured velocity field. It is shown that the numerical results match the observed velocity patterns well overall except for a variance and small systematic scaling which can be attributed to the known experimental uncertainty in the MRI measurements. The comparisons presented here provide strong validation of the pore-scale simulation methods and new insights for interpretation of uncertainty in MRI measurements of pore-scale velocity. This study also provides a potential benchmark for future comparison of other pore-scale simulation methods. 2012 Elsevier Science.

  2. Phase-contrast magnetic resonance imaging reveals net retrograde aqueductal flow in idiopathic normal pressure hydrocephalus.

    Science.gov (United States)

    Ringstad, Geir; Emblem, Kyrre Eeg; Eide, Per Kristian

    2016-06-01

    OBJECT The objective of this study was to assess the net aqueductal stroke volume (ASV) and CSF aqueductal flow rate derived from phase-contrast MRI (PC-MRI) in patients with probable idiopathic normal pressure hydrocephalus (iNPH) before and after ventriculoperitoneal shunt surgery, and to compare observations with intracranial pressure (ICP) scores. METHODS PC-MRI at the level of the sylvian aqueduct was undertaken in patients undergoing assessment for probable iNPH. Aqueductal flow in the craniocaudal direction was defined as positive, or antegrade flow, and net ASV was calculated by subtracting retrograde from antegrade aqueductal flow. Aqueductal flow rate per minute was calculated by multiplying net ASV by heart rate. During the same hospital admission, clinical examination was performed using NPH score and overnight continuous ICP monitoring. Twelve patients were followed prospectively 12 months after shunt placement with clinical assessment and a second PC-MRI. The study also included 2 healthy controls. RESULTS Among 21 patients examined for iNPH, 17 (81%) received a shunt (shunt group), and 4 were treated conservatively (conservative group). Among the patients with shunts, a clinical improvement was observed in 16 (94%) of the 17. Net ASV was negative in 16 (76%) of 21 patients before shunt placement and in 5 (42%) of 12 patients after shunt placement, and increased from a median of -5 μl (range -175 to 27 μl) to a median of 1 μl (range -61 to 30 μl; p = 0.04). Among the 12 patients with PC-MRI after shunt placement, 11 were shunt responders, and in 9 of these 11 either a reduced magnitude of retrograde aqueductal flow, or a complete reversal from retrograde to antegrade flow, occurred. Net ASV was significantly lower in the shunt group than in the conservative group (p = 0.01). The aqueductal flow rate increased from -0.56 ml/min (range -12.78 to 0.58 ml/min) to 0.06 ml/min (range -4.51 to 1.93 ml/min; p = 0.04) after shunt placement. CONCLUSIONS In

  3. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Us News Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance ... if possible, or removed prior to the MRI scan. Because they can interfere with the magnetic field ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to Magnetic ...

  5. Magnetic resonance imaging of cerebral blood flow in animal stroke models

    Directory of Open Access Journals (Sweden)

    Qiang Shen

    2016-01-01

    Full Text Available Perfusion could provide useful information on the metabolic status and functional status of tissues and organs. This review summarizes the most commonly used perfusion measurement methods: Dynamic susceptibility contrast (DSC and arterial spin labeling (ASL and their applications in experimental stroke. Some new developments of cerebral blood flow (CBF techniques in animal models are also discussed.

  6. Magnetic Resonance Imaging of Cerebral Blood Flow in Animal Stroke Models

    OpenAIRE

    Qiang Shen; Timothy Q Duong

    2016-01-01

    Perfusion could provide useful information on the metabolic status and functional status of tissues and organs. This review summarizes the most commonly used perfusion measurement methods: Dynamic susceptibility contrast (DSC) and arterial spin labeling (ASL) and their applications in experimental stroke. Some new developments of cerebral blood flow (CBF) techniques in animal models are also discussed.

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... type your comment or suggestion into the following text box: Comment: E-mail: Area code: Phone no: ... Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging ( ...

  8. Advances in magnetic resonance 11

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 11, presents a variety of contributions to the theory and practice of magnetic resonance. The book contains three chapters and begins with a discussion of the principles and applications of dynamic nuclear polarization, with emphasis on molecular motions and collisions, intermolecular couplings, and chemical interactions. Subsequent chapters focus on the assessment of a proposed broadband decoupling method and studies of time-domain (or Fourier transform) multiple-quantum nuclear magnetic resonance.

  9. Functional Relevance of Coronary Artery Disease by Cardiac Magnetic Resonance and Cardiac Computed Tomography: Myocardial Perfusion and Fractional Flow Reserve

    Directory of Open Access Journals (Sweden)

    Gianluca Pontone

    2015-01-01

    Full Text Available Coronary artery disease (CAD is one of the leading causes of morbidity and mortality and it is responsible for an increasing resource burden. The identification of patients at high risk for adverse events is crucial to select those who will receive the greatest benefit from revascularization. To this aim, several non-invasive functional imaging modalities are usually used as gatekeeper to invasive coronary angiography, but the diagnostic yield of elective invasive coronary angiography remains unfortunately low. Stress myocardial perfusion imaging by cardiac magnetic resonance (stress-CMR has emerged as an accurate technique for diagnosis and prognostic stratification of the patients with known or suspected CAD thanks to high spatial and temporal resolution, absence of ionizing radiation, and the multiparametric value including the assessment of cardiac anatomy, function, and viability. On the other side, cardiac computed tomography (CCT has emerged as unique technique providing coronary arteries anatomy and more recently, due to the introduction of stress-CCT and noninvasive fractional flow reserve (FFR-CT, functional relevance of CAD in a single shot scan. The current review evaluates the technical aspects and clinical experience of stress-CMR and CCT in the evaluation of functional relevance of CAD discussing the strength and weakness of each approach.

  10. Functional Relevance of Coronary Artery Disease by Cardiac Magnetic Resonance and Cardiac Computed Tomography: Myocardial Perfusion and Fractional Flow Reserve

    Science.gov (United States)

    Andreini, Daniele; Bertella, Erika; Mushtaq, Saima; Guaricci, Andrea Igoren; Pepi, Mauro

    2015-01-01

    Coronary artery disease (CAD) is one of the leading causes of morbidity and mortality and it is responsible for an increasing resource burden. The identification of patients at high risk for adverse events is crucial to select those who will receive the greatest benefit from revascularization. To this aim, several non-invasive functional imaging modalities are usually used as gatekeeper to invasive coronary angiography, but the diagnostic yield of elective invasive coronary angiography remains unfortunately low. Stress myocardial perfusion imaging by cardiac magnetic resonance (stress-CMR) has emerged as an accurate technique for diagnosis and prognostic stratification of the patients with known or suspected CAD thanks to high spatial and temporal resolution, absence of ionizing radiation, and the multiparametric value including the assessment of cardiac anatomy, function, and viability. On the other side, cardiac computed tomography (CCT) has emerged as unique technique providing coronary arteries anatomy and more recently, due to the introduction of stress-CCT and noninvasive fractional flow reserve (FFR-CT), functional relevance of CAD in a single shot scan. The current review evaluates the technical aspects and clinical experience of stress-CMR and CCT in the evaluation of functional relevance of CAD discussing the strength and weakness of each approach. PMID:25692133

  11. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles ... Videos related to Magnetic Resonance Imaging (MRI) - Head Sponsored ...

  12. Advances in magnetic resonance 6

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 6 focuses on the theoretical and practical aspects of applying magnetic resonance methods to various problems in physical chemistry, emphasizing the different aspects of the exegesis of these problems. This book discusses the gas phase magnetic resonance of electronically excited molecules; techniques for observing excited electronic states; NMR studies in liquids at high pressure; and effect of pressure on self-diffusion in liquids. The nuclear magnetic resonance investigations of organic free radicals; measurement of proton coupling constants by NMR; an

  13. Magnetic resonance imaging analysis on the in-situ mixing zone of CO2 miscible displacement flows in porous media

    Science.gov (United States)

    Song, Yongchen; Yang, Wenzhe; Wang, Dayong; Yang, Mingjun; Jiang, Lanlan; Liu, Yu; Zhao, Yuechao; Dou, Binlin; Wang, Zhiguo

    2014-06-01

    The in-situ mixing zone represents dynamic characteristics of CO2 miscible displacement flows, which is important for carbon dioxide enhanced oil recovery (CO2-EOR) projects. However, the migration characteristics of the in-situ mixing zone under reservoir conditions has been neither well studied nor fully understood. The in-situ mixing zone with the flowing mixture of supercritical CO2 and n-decane (nC10) was investigated by using a magnetic resonance imaging apparatus at a reservoir condition of 8.5 MPa and 37.8 °C in porous media. The experimental results showed that the CO2-frontal velocity was larger than the mixing-frontal velocity. The mixing zone length was linearly declined in the miscible displacement process. And the declining rate of the mixing zone length was increased with injection rate. It indicates that the mixing zone length is not constant in a vertically stable CO2 misible displacement and a volume contraction due to phase behavior effects may occur. Then, an error function based on the convection-dispersion equation was fitted with CO2 miscible displacement experiments. The error function was well fitted both at a series of fixed core positions and a series of fixed displacement times. Furthermore, the longitudinal dispersion coefficients (Klx and Klt) and the longitudinal Peclet numbers (Ped and PeL) were quantified from the fitting results. The evolutions of the longitudinal dispersion coefficient were reduced along the displacement time. And the declining rate was increased with injection rate. And with proceeding, the longitudinal dispersion coefficient was tending towards stability and constant. But the evolutions of the longitudinal Peclet numbers were increased along the displacement time. And the increasing rate was increased with injection rate.

  14. Nuclear Magnetic resonance studies of the solvation of a high-performance nonaqueous redox flow electrolyte

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Xuchu; Hu, Mary Y.; Wei, Xiaoliang; Wang, Wei; Mueller, Karl T.; Chen, Zhong; Hu, Jian Z.

    2016-03-15

    Understanding the solvation structures of electrolytes is important for developing nonaqueous redox flow batteries that hold considerable potential for future large scale energy storage systems. The utilization of an emerging ionic-derivative ferrocene compounds, ferrocenylmethyl dimethyl ethyl ammonium bis (triflyoromethanesulfonyl)imide (Fc1N112-TFSI), has recently overcome the issue of solubility in the supporting electrolyte. In this work, 13C1H and 17O NMR investigations were carried out using solvent. It was observed that the spectra of 13C experience changes of chemical shifts while those of 17O undergo line width broadening, indicating interactions between solute and solvent molecules

  15. Partially orthogonal resonators for magnetic resonance imaging

    Science.gov (United States)

    Chacon-Caldera, Jorge; Malzacher, Matthias; Schad, Lothar R.

    2017-02-01

    Resonators for signal reception in magnetic resonance are traditionally planar to restrict coil material and avoid coil losses. Here, we present a novel concept to model resonators partially in a plane with maximum sensitivity to the magnetic resonance signal and partially in an orthogonal plane with reduced signal sensitivity. Thus, properties of individual elements in coil arrays can be modified to optimize physical planar space and increase the sensitivity of the overall array. A particular case of the concept is implemented to decrease H-field destructive interferences in planar concentric in-phase arrays. An increase in signal to noise ratio of approximately 20% was achieved with two resonators placed over approximately the same planar area compared to common approaches at a target depth of 10 cm at 3 Tesla. Improved parallel imaging performance of this configuration is also demonstrated. The concept can be further used to increase coil density.

  16. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... resonance imaging (MRI) uses a powerful magnetic field, radio waves and a computer to produce detailed pictures ... medical conditions. MRI uses a powerful magnetic field, radio frequency pulses and a computer to produce detailed ...

  17. Functional Magnetic Resonance Imaging Measures of Blood Flow Patterns in the Human Auditory Cortex in Response to Sound.

    Science.gov (United States)

    Huckins, Sean C.; Turner, Christopher W.; Doherty, Karen A.; Fonte, Michael M.; Szeverenyi, Nikolaus M.

    1998-01-01

    This study examined the feasibility of using functional magnetic resonance imaging (fMRI) in auditory research by testing the reliability of scanning parameters using high resolution and high signal-to-noise ratios. Findings indicated reproducibility within and across listeners for consonant-vowel speech stimuli and reproducible results within and…

  18. Magnetic resonance urography.

    Science.gov (United States)

    Leyendecker, John R; Gianini, John W

    2009-07-01

    Excellent contrast resolution and lack of ionizing radiation make magnetic resonance urography (MRU) a promising technique for noninvasively evaluating the entire urinary tract. While MRU currently lags behind CT urography (CTU) in spatial resolution and efficiency, new hardware and sequence developments have contributed to a resurgence of interest in MRU techniques. By combining unenhanced sequences with multiphase contrast-enhanced and excretory phase imaging, a comprehensive assessment of the kidneys, ureters, bladder, and surrounding structures is possible with image quality rivaling that obtained with other techniques. At the same time, formidable challenges remain to be overcome and further clinical validation is necessary before MRU can replace other forms of urography. In this article, we demonstrate the current potential of MRU to demonstrate a spectrum of urologic pathology involving the kidneys, ureters, and bladder while discussing the limitations and current status of this evolving technique.

  19. Blood flow and muscle bio-energetics by 31P-nuclear magnetic resonance after local cold acclimation.

    Science.gov (United States)

    Savourey, G; Clerc, L; Vallerand, A L; Leftheriotis, G; Mehier, H; Bittel, J H

    1992-01-01

    To clarify the origin of local cold adaptation and to define precisely its influence on muscle bio-energetics during local exercise, five subjects were subjected to repeated 5 degrees C cold water immersion of the right hand and forearm. The first aim of our investigation was therefore carried out by measuring local skin temperatures and peripheral blood flow during a cold hand test (5 degrees C, 5 min) followed by a 10-min recovery period. The 31P by nuclear magnetic resonance (31PNMR) muscle bio-energetic changes, indicating possible heat production changes, were measured during the recovery period. The second aim of our investigation was carried out by measuring 31PNMR muscle bioenergetics during handgrip exercise (10% of the maximal voluntary contraction for 5 min followed by a 10-min recovery period) performed both at a comfortable ambient temperature (22 degrees C; E) and after a cold hand test (EC), before and after local cold adaptation. Local cold adaptation, confirmed by warmer skin temperatures of the extremities (+30%, P less than 0.05), was related more to an increased peripheral blood flow, as shown by the smaller decrease in systolic peak [-245 (SEM 30) Hz vs -382 (SEM 95) Hz, P less than 0.05] than to a change in local heat production, because muscle bioenergetics did not vary. Acute local cold immersion decreased the inorganic phosphate:phosphocreatine (PC) ratio during EC compared to E [+0.006 (SEM 0.010) vs +0.078 (SEM 0.002) before acclimation and +0.029 (SEM 0.002) vs +0.090 (SEM 0.002) after acclimation respectively, P less than 0.05] without significant change in the PC:beta-adenosine triphosphate ratio and pH. Local adaptation did not modify these results statistically. The recovery of PC during E increased after acclimation [9.0 (SEM 0.2) min vs 3.0 (SEM 0.4) min, P less than 0.05]. These results suggested that local cold adaptation is related more to peripheral blood flow changes than to increased metabolic heat production in the muscle.

  20. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's (Pediatric) CT (Computed Tomography) Magnetic Resonance Imaging ( ...

  1. Advances in magnetic resonance 12

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 12, presents a variety of contributions to the theory and practice of magnetic resonance. The book contains six chapters and begins with a discussion of diffusion and self-diffusion measurements by nuclear magnetic resonance. This is followed by separate chapters on spin-lattice relaxation time in hydrogen isotope mixtures; the principles of optical detection of nuclear spin alignment and nuclear quadropole resonance; and the spin-1 behavior, including the relaxation of the quasi-invariants of the motion of a system of pairs of dipolar coupled spin-1/2 nu

  2. Left ventricular fluid kinetic energy time curves in heart failure from cardiovascular magnetic resonance 4D flow data.

    Science.gov (United States)

    Kanski, Mikael; Arvidsson, Per M; Töger, Johannes; Borgquist, Rasmus; Heiberg, Einar; Carlsson, Marcus; Arheden, Håkan

    2015-12-20

    Measurement of intracardiac kinetic energy (KE) provides new insights into cardiac hemodynamics and may improve assessment and understanding of heart failure. We therefore aimed to investigate left ventricular (LV) KE time curves in patients with heart failure and in controls. Patients with heart failure (n = 29, NYHA class I-IV) and controls (n = 12) underwent cardiovascular magnetic resonance (CMR) including 4D flow. The vortex-ring boundary was computed using Lagrangian coherent structures. The LV endocardium and vortex-ring were manually delineated and KE was calculated as ½mv(2) of the blood within the whole LV and the vortex ring, respectively. The systolic average KE was higher in patients compared to controls (2.2 ± 1.4 mJ vs 1.6 ± 0.6 mJ, p = 0.048), but lower when indexing to EDV (6.3 ± 2.2 μJ/ml vs 8.0 ± 2.1 μJ/ml, p = 0.025). No difference was seen in diastolic average KE (3.2 ± 2.3 mJ vs 2.0 ± 0.8 mJ, p = 0.13) even when indexing to EDV (9.0 ± 4.4 μJ/ml vs 10.2 ± 3.3 μJ/ml, p = 0.41). In patients, a smaller fraction of diastolic average KE was observed inside the vortex ring compared to controls (72 ± 6% vs 54 ± 9%, p < 0.0001). Three distinctive KE time curves were seen in patients which were markedly different from findings in controls, and with a moderate agreement between KE time curve patterns and degree of diastolic dysfunction (Cohen's kappa = 0.49), but unrelated to NYHA classification (p = 0.12), or 6-minute walk test (p = 0.72). Patients with heart failure exhibit higher systolic average KE compared to controls, suggesting altered intracardiac blood flow. The different KE time curves seen in patients may represent a conceptually new approach for heart failure classification.

  3. Pediatric magnetic resonance urography.

    Science.gov (United States)

    Jones, Richard A; Grattan-Smith, J Damien; Little, Stephen

    2011-03-01

    Magnetic resonance urography (MRU) is a powerful clinical tool that fuses anatomic information with functional data in a single test without the use of ionizing radiation. This article provides an overview of the technical aspects, as well as common clinical applications with an emphasis on the evaluation of hydronephrosis. A fluid challenge is an essential part of our MRU protocol and enables the definition of compensated or decompensated kidneys within the spectrum of hydronephrosis. This classification may have prognostic implications when surgery is being considered. In addition, underlying uropathy can be identified on the anatomical scans and renal scarring can be seen on both the anatomical and dynamic scans. MRU can identify and categorize dysmorphic kidneys in vivo and may provide insight into congenital abnormalities seen in conjunction with vesicoureteric reflux. MRU is still in its infancy and as the technique develops and becomes widely available, it seems likely that it will supplant renal scintigraphy in the evaluation of renal tract disorders in children. Copyright © 2011 Wiley-Liss, Inc.

  4. Advances in magnetic resonance 1

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 1, discusses developments in various areas of magnetic resonance. The subject matter ranges from original theoretical contributions through syntheses of points of view toward series of phenomena to critical and painstaking tabulations of experimental data. The book contains six chapters and begins with a discussion of the theory of relaxation processes. This is followed by separate chapters on the development of magnetic resonance techniques for studying rate processes in chemistry and the application of these techniques to various problems; the geometri

  5. Advances in magnetic resonance 9

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 9 describes the magnetic resonance in split constants and dipolar relaxation. This book discusses the temperature-dependent splitting constants in the ESR spectra of organic free radicals; temperature-dependent splittings in ion pairs; and magnetic resonance induced by electrons. The electron impact excitation of atoms and molecules; intramolecular dipolar relaxation in multi-spin systems; and dipolar cross-correlation problem are also elaborated. This text likewise covers the NMR studies of molecules oriented in thermotropic liquid crystals and diffusion

  6. Magnetic Resonance Imaging

    Science.gov (United States)

    ... metallic objects from being attracted by the powerful magnet of the MR system, you will typically receive ... teeth with magnetic keepers Other implants that involve magnets Medication patch (i.e., transdermal patch) that contains ...

  7. Magnetic resonance energy and topological resonance energy.

    Science.gov (United States)

    Aihara, Jun-Ichi

    2016-04-28

    Ring-current diamagnetism of a polycyclic π-system is closely associated with thermodynamic stability due to the individual circuits. Magnetic resonance energy (MRE), derived from the ring-current diamagnetic susceptibility, was explored in conjunction with graph-theoretically defined topological resonance energy (TRE). For many aromatic molecules, MRE is highly correlative with TRE with a correlation coefficient of 0.996. For all π-systems studied, MRE has the same sign as TRE. The only trouble with MRE may be that some antiaromatic and non-alternant species exhibit unusually large MRE-to-TRE ratios. This kind of difficulty can in principle be overcome by prior geometry-optimisation or by changing spin multiplicity. Apart from the semi-empirical resonance-theory resonance energy, MRE is considered as the first aromatic stabilisation energy (ASE) defined without referring to any hypothetical polyene reference.

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI of the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive ... of page What are some common uses of the procedure? MR imaging of the head is performed ...

  9. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the limitations of MRI of the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) ... ray, CT and ultrasound. top of page How is the procedure performed? MRI examinations may be performed ...

  10. Magnetic Resonance Imaging (MRI) Safety

    Science.gov (United States)

    ... Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) Safety What is MRI and how does ... the area being scanned include: Metallic spinal rod Plates, pins, screws, or metal mesh used to repair ...

  11. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... bore which can be more comfortable for larger size patients or patients with claustrophobia. Other MRI machines ... Gallery Magnetic Resonance Imaging (MRI) procedure View full size with caption Pediatric Content Some imaging tests and ...

  12. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... bore which can be more comfortable for larger size patients or patients with claustrophobia. Other MRI machines ... for magnetic resonance imaging (MRI) exam. View full size with caption Pediatric Content Some imaging tests and ...

  13. Magnetic resonance imaging the basics

    CERN Document Server

    Constantinides, Christakis

    2014-01-01

    Magnetic resonance imaging (MRI) is a rapidly developing field in basic applied science and clinical practice. Research efforts in this area have already been recognized with five Nobel prizes awarded to seven Nobel laureates in the past 70 years. Based on courses taught at The Johns Hopkins University, Magnetic Resonance Imaging: The Basics provides a solid introduction to this powerful technology. The book begins with a general description of the phenomenon of magnetic resonance and a brief summary of Fourier transformations in two dimensions. It examines the fundamental principles of physics for nuclear magnetic resonance (NMR) signal formation and image construction and provides a detailed explanation of the mathematical formulation of MRI. Numerous image quantitative indices are discussed, including (among others) signal, noise, signal-to-noise, contrast, and resolution. The second part of the book examines the hardware and electronics of an MRI scanner and the typical measurements and simulations of m...

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... data suggest that it is safe to continue breastfeeding after receiving intravenous contrast. For further information please ... that magnetic resonance imaging harms the fetus, pregnant women usually are advised not to have an MRI ...

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... Brain Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to ...

  16. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... is not harmful, but it may cause some medical devices to malfunction. Most orthopedic implants pose no ... Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. ...

  17. Magnetic Resonance Imaging (MRI) -- Head

    Science.gov (United States)

    ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... that magnetic resonance imaging harms the fetus, pregnant women usually are advised not to have an MRI ...

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... that magnetic resonance imaging harms the fetus, pregnant women usually are advised not to have an MRI ...

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI of the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive ... of page What are some common uses of the procedure? MR imaging of the head is performed ...

  20. Advances in magnetic resonance 2

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 2, features a mixture of experimental and theoretical contributions. The book contains four chapters and begins with an ambitious and general treatment of the problem of signal-to-noise ratio in magnetic resonance. This is followed by separate chapters on the interpretation of nuclear relaxation in fluids, with special reference to hydrogen; and various aspects of molecular theory of importance in NMR.

  1. Advances in magnetic resonance 4

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 4 deals with the relaxation, irradiation, and other dynamical effects that is specific to systems having resolved structure in their magnetic resonance spectra. This book discusses the anisotropic rotation of molecules in liquids by NMR quadrupolar relaxation; rotational diffusion constants; alternating linewidth effect; and theoretical formulations of the problem. The line shapes in high-resolution NMR; matrix representations of the equations of motion; matrix representations of the equations of motion; and intramolecular hydrogen bonds are also delibera

  2. Intraoperative magnetic resonance imaging.

    Science.gov (United States)

    Hall, Walter A; Truwit, Charles L

    2011-01-01

    Neurosurgeons have become reliant on image-guidance to perform safe and successful surgery both time-efficiently and cost-effectively. Neuronavigation typically involves either rigid (frame-based) or skull-mounted (frameless) stereotactic guidance derived from computed tomography (CT) or magnetic resonance imaging (MRI) that is obtained days or immediately before the planned surgical procedure. These systems do not accommodate for brain shift that is unavoidable once the cranium is opened and cerebrospinal fluid is lost. Intraoperative MRI (ioMRI) systems ranging in strength from 0.12 to 3 Tesla (T) have been developed in part because they afford neurosurgeons the opportunity to accommodate for brain shift during surgery. Other distinct advantages of ioMRI include the excellent soft tissue discrimination, the ability to view the surgical site in three dimensions, and the ability to "see" tumor beyond the surface visualization of the surgeon's eye, either with or without a surgical microscope. The enhanced ability to view the tumor being biopsied or resected allows the surgeon to choose a safe surgical corridor that avoids critical structures, maximizes the extent of the tumor resection, and confirms that an intraoperative hemorrhage has not resulted from surgery. Although all ioMRI systems allow for basic T1- and T2-weighted imaging, only high-field (>1.5 T) MRI systems are capable of MR spectroscopy (MRS), MR angiography (MRA), MR venography (MRV), diffusion-weighted imaging (DWI), and brain activation studies. By identifying vascular structures with MRA and MRV, it may be possible to prevent their inadvertent injury during surgery. Biopsying those areas of elevated phosphocholine on MRS may improve the diagnostic yield for brain biopsy. Mapping out eloquent brain function may influence the surgical path to a tumor being resected or biopsied. The optimal field strength for an ioMRI-guided surgical system and the best configuration for that system are as yet

  3. Magnetic resonance imaging; Imagerie par resonance magnetique

    Energy Technology Data Exchange (ETDEWEB)

    Fontanel, F. [Centre Hospitalier, 40 - Mont-de -Marsan (France); Clerc, T. [Centre Hospitalier Universitaire, 76 - Rouen (France); Theolier, S. [Hospice Civils de Lyon, 69 - Lyon (France); Verdenet, J. [Centre Hospitalier Universitaire, 25 - Besancon (France)

    1997-04-01

    The last improvements in nuclear magnetic resonance imaging are detailed here, society by society with an expose of their different devices. In the future the different technological evolutions will be on a faster acquisition, allowing to reduce the examination time, on the development of a more acute cardiac imaging, of a functional neuro-imaging and an interactive imaging for intervention. With the contrast products, staying a longer time in the vascular area, the angiography will find its place. Finally, the studies on magnetic fields should allow to increase the volume to examine. (N.C.).

  4. Comparison of cerebral blood flow measurement with [15O]-water positron emission tomography and arterial spin labeling magnetic resonance imaging: A systematic review.

    Science.gov (United States)

    Fan, Audrey P; Jahanian, Hesamoddin; Holdsworth, Samantha J; Zaharchuk, Greg

    2016-05-01

    Noninvasive imaging of cerebral blood flow provides critical information to understand normal brain physiology as well as to identify and manage patients with neurological disorders. To date, the reference standard for cerebral blood flow measurements is considered to be positron emission tomography using injection of the [(15)O]-water radiotracer. Although [(15)O]-water has been used to study brain perfusion under normal and pathological conditions, it is not widely used in clinical settings due to the need for an on-site cyclotron, the invasive nature of arterial blood sampling, and experimental complexity. As an alternative, arterial spin labeling is a promising magnetic resonance imaging technique that magnetically labels arterial blood as it flows into the brain to map cerebral blood flow. As arterial spin labeling becomes more widely adopted in research and clinical settings, efforts have sought to standardize the method and validate its cerebral blood flow values against positron emission tomography-based cerebral blood flow measurements. The purpose of this work is to critically review studies that performed both [(15)O]-water positron emission tomography and arterial spin labeling to measure brain perfusion, with the aim of better understanding the accuracy and reproducibility of arterial spin labeling relative to the positron emission tomography reference standard.

  5. Magnetic Resonance (MR) Defecography

    Science.gov (United States)

    ... their nature and the strength of the MRI magnet. Many implanted devices will have a pamphlet explaining ... large cylinder-shaped tube surrounded by a circular magnet. You will lie on a moveable examination table ...

  6. Advances in magnetic resonance 5

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 5 deals with the interpretation of ESR spectra and provides descriptions of experimental apparatus. This book discusses the halogen hyperfine interactions; organic radicals in single crystals; pulsed-Fourier-transform nuclear magnetic resonance spectrometer; and inhomogenizer and decoupler. The spectrometers for multiple-pulse NMR; weak collision theory of relaxation in the rotating frame; and spin Hamiltonian for the electron spin resonance of irradiated organic single crystals are also deliberated. This text likewise covers the NMR in helium three and m

  7. Portal hypertension in patients with cirrhosis: indirect assessment of hepatic venous pressure gradient by measuring azygos flow with 2D-cine phase-contrast magnetic resonance imaging.

    Science.gov (United States)

    Gouya, Hervé; Grabar, Sophie; Vignaux, Olivier; Saade, Anastasia; Pol, Stanislas; Legmann, Paul; Sogni, Philippe

    2016-07-01

    To measure azygos, portal and aortic flow by two-dimensional cine phase-contrast magnetic resonance imaging (2D-cine PC MRI), and to compare the MRI values to hepatic venous pressure gradient (HVPG) measurements, in patients with cirrhosis. Sixty-nine patients with cirrhosis were prospectively included. All patients underwent HVPG measurements, upper gastrointestinal endoscopy and 2D-cine PC MRI measurements of azygos, portal and aortic blood flow. Univariate and multivariate regression analyses were used to evaluate the correlation between the blood flow and HVPG. The performance of 2D-cine PC MRI to diagnose severe portal hypertension (HVPG ≥ 16 mmHg) was determined by receiver operating characteristic curve (ROC) analysis, and area under the curves (AUC) were compared. Azygos and aortic flow values were associated with HVPG in univariate linear regression model. Azygos flow (p cine PC MRI is a promising technique to evaluate significant portal hypertension in patients with cirrhosis. • Noninvasive HVPG assessment can be performed with MRI azygos flow. • Azygos MRI flow is an easy-to-measure marker to detect significant portal hypertension. • MRI flow is more specific that varice grade to detect portal hypertension.

  8. Turbulent Kinetic Energy Assessed by Multipoint 4-Dimensional Flow Magnetic Resonance Imaging Provides Additional Information Relative to Echocardiography for the Determination of Aortic Stenosis Severity.

    Science.gov (United States)

    Binter, Christian; Gotschy, Alexander; Sündermann, Simon H; Frank, Michelle; Tanner, Felix C; Lüscher, Thomas F; Manka, Robert; Kozerke, Sebastian

    2017-06-01

    Turbulent kinetic energy (TKE), assessed by 4-dimensional (4D) flow magnetic resonance imaging, is a measure of energy loss in disturbed flow as it occurs, for instance, in aortic stenosis (AS). This work investigates the additional information provided by quantifying TKE for the assessment of AS severity in comparison to clinical echocardiographic measures. Fifty-one patients with AS (67±15 years, 20 female) and 10 healthy age-matched controls (69±5 years, 5 female) were prospectively enrolled to undergo multipoint 4D flow magnetic resonance imaging. Patients were split into 2 groups (severe and mild/moderate AS) according to their echocardiographic mean pressure gradient. TKE values were integrated over the aortic arch to obtain peak TKE. Integrating over systole yielded total TKEsys and by normalizing for stroke volume, normalized TKEsys was obtained. Mean pressure gradient and TKE correlated only weakly (R(2)=0.26 for peak TKE and R(2)=0.32 for normalized TKEsys) in the entire study population including control subjects, while no significant correlation was observed in the AS patient group. In the patient population with dilated ascending aorta, both peak TKE and total TKEsys were significantly elevated (Penergy losses associated with bicuspid aortic valves and dilated ascending aortic geometries that are not assessable by current echocardiographic measures. These findings indicate that TKE may provide complementary information to echocardiography, helping to distinguish within the heterogeneous population of patients with moderate to severe AS. © 2017 American Heart Association, Inc.

  9. Interdependencies of aortic arch secondary flow patterns, geometry, and age analysed by 4-dimensional phase contrast magnetic resonance imaging at 3 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Frydrychowicz, Alex [University Hospital Schleswig-Holstein, Clinic for Radiology and Nuclear Medicine, Luebeck (Germany); Berger, Alexander; Russe, Maximilian F.; Bock, Jelena [University Hospital Freiburg, Department of Radiology, Medical Physics, Freiburg (Germany); Munoz del Rio, Alejandro [University of Wisconsin - Madison, Departments of Radiology and Medical Physics, Madison, WI (United States); Harloff, Andreas [University Hospital Freiburg, Department of Neurology and Clinical Neurophysiology, Freiburg (Germany); Markl, Michael [University Hospital Freiburg, Department of Radiology, Medical Physics, Freiburg (Germany); Northwestern University, Departments of Radiology and Biomedical Engineering, Chicago, IL (United States)

    2012-05-15

    It was the aim to analyse the impact of age, aortic arch geometry, and size on secondary flow patterns such as helix and vortex flow derived from flow-sensitive magnetic resonance imaging (4D PC-MRI). 62 subjects (age range = 20-80 years) without circumscribed pathologies of the thoracic aorta (ascending aortic (AAo) diameter: 3.2 {+-} 0.6 cm [range 2.2-5.1]) were examined by 4D PC-MRI after IRB-approval and written informed consent. Blood flow visualisation based on streamlines and time-resolved 3D particle traces was performed. Aortic diameter, shape (gothic, crook-shaped, cubic), angle, and age were correlated with existence and extent of secondary flow patterns (helicity, vortices); statistical modelling was performed. Helical flow was the typical pattern in standard crook-shaped aortic arches. With altered shapes and increasing age, helicity was less common. AAo diameter and age had the highest correlation (r = 0.69 and 0.68, respectively) with number of detected vortices. None of the other arch geometric or demographic variables (for all, P {>=} 0.177) improved statistical modelling. Substantially different secondary flow patterns can be observed in the normal thoracic aorta. Age and the AAo diameter were the parameters correlating best with presence and amount of vortices. Findings underline the importance of age- and geometry-matched control groups for haemodynamic studies. (orig.)

  10. [Pulmonary blood flow measurement using magnetic resonance imaging (MRI) without contrast medium;comparison of phase contrast MRI and perfusion-ventilation scintigraphy].

    Science.gov (United States)

    Yatsuyanagi, Eiji; Sato, Kazuhiro; Kikuchi, Keisuke; Saito, Hirotsugu

    2014-02-01

    To define the accuracy of pulmonary arterial blood flow (PA-flow) measured by phase contrast magnetic resonance imaging (PC-MRI), we compared the PA-flow data of PC-MRI with the data of perfusion-ventilation lung scintigraphy. Eighteen patients who preoperatively underwent PA-flow measurement using PC-MRI and perfusion-ventilation lung scintigraphy were evaluated. The PA-flow (cm3/sec) of MRI was calculated by multiplying maximum velocity (cm/sec) by region of interest (ROI) area (cm2) of measured main pulmonary artery using phase contrast method. The left to right ratio (R/L ratio) of PA-flow measured by PC-MRI was compared with the R/L ratios of the date of perfusion-ventilation lung scintigraphy. The R/L ratios of PC-MRI and perfusion lung scintigraphy were 1.43 ± 1.07 and 1.35 ± 0.82, respectively. Both ratios showed excellent correlation( y=-0.50+1.30x, r=0.99,pperfusion lung scintigraphy in the patients with a past history of lung resection, even if their R/L ratios of perfusion lung scintigraphy differed from those of ventilation lung scintigraphy. These results revealed that the PA-flow could be accurately measured by PC-MRI without contrast medium and nuclear medicine instruments.

  11. Diagnosis of moyamoya disease on magnetic resonance imaging: are flow voids in the basal ganglia an essential criterion for definitive diagnosis?

    Science.gov (United States)

    Mikami, Takeshi; Sugino, Toshiya; Ohtaki, Shunya; Houkin, Kiyohiro; Mikuni, Nobuhiro

    2013-08-01

    Flow voids in the basal ganglia cannot always be recognized on magnetic resonance imaging, even in patients with typical moyamoya disease. In this report, flow voids in the basal ganglia and cisternal flow voids of the sylvian valley were evaluated in patients with moyamoya disease, and their diagnostic value was verified. A total of 41 consecutive patients with moyamoya disease were included in this analysis. The number of flow voids in the basal ganglia and the sylvian valley were counted on each side by 3 observers. Then the numbers of flow voids were compared between the patients with moyamoya disease and controls. The patients with moyamoya disease had a significantly higher mean number of flow voids in the basal ganglia and the sylvian valley (P moyamoya disease. Comparative analysis using the area under the receiver operating curve indicated that the evaluation of flow voids in the sylvian valley was significantly superior method to that in the basal ganglia (P moyamoya disease was 6. Based on these findings, we recommend a definitive diagnosis of moyamoya disease should include assessment for abnormal vessels around the terminal portions of the internal carotid arteries.

  12. GHz nuclear magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Cross, T.A.; Drobny, G.; Trewhella, J.

    1994-12-01

    For the past dozen years, 500- and 600-MHz spectrometers have become available in many laboratories. The first 600-MHz NMR spectrometer (at Carnegie Mellon University) was commissioned more than 15 years ago and, until 1994, represented the highest field available for high-resolution NMR. This year, we have witnessed unprecedented progress in the development of very high field magnets for NMR spectroscopy, including the delivery of the first commercial 750-MHz NMR spectrometers. In addition, NMR signals have been obtained from 20-Tesla magnets (850 MHz for {sup 1}H`s) at both Los Alamos National Laboratory and Florida State University in the NHMFL (National High Magnetic Field Laboratory). These preliminary experiments have been performed in magnets with 100-ppm homogeneity, but a 20-Tesla magnet developed for the NHMFL will be brought to field this year with a projected homogeneity of 0.1 ppm over a 1-cm-diam spherical volume.

  13. Bifurcation magnetic resonance in films magnetized along hard magnetization axis

    Energy Technology Data Exchange (ETDEWEB)

    Vasilevskaya, Tatiana M., E-mail: t_vasilevs@mail.ru [Ulyanovsk State University, Leo Tolstoy 42, 432017 Ulyanovsk (Russian Federation); Sementsov, Dmitriy I.; Shutyi, Anatoliy M. [Ulyanovsk State University, Leo Tolstoy 42, 432017 Ulyanovsk (Russian Federation)

    2012-09-15

    We study low-frequency ferromagnetic resonance in a thin film magnetized along the hard magnetization axis performing an analysis of magnetization precession dynamics equations and numerical simulation. Two types of films are considered: polycrystalline uniaxial films and single-crystal films with cubic magnetic anisotropy. An additional (bifurcation) resonance initiated by the bistability, i.e. appearance of two closely spaced equilibrium magnetization states is registered. The modification of dynamic modes provoked by variation of the frequency, amplitude, and magnetic bias value of the ac field is studied. Both steady and chaotic magnetization precession modes are registered in the bifurcation resonance range. - Highlights: Black-Right-Pointing-Pointer An additional bifurcation resonance arises in a case of a thin film magnetized along HMA. Black-Right-Pointing-Pointer Bifurcation resonance occurs due to the presence of two closely spaced equilibrium magnetization states. Black-Right-Pointing-Pointer Both regular and chaotic precession modes are realized within bifurcation resonance range. Black-Right-Pointing-Pointer Appearance of dynamic bistability is typical for bifurcation resonance.

  14. Deuterium Nuclear Magnetic Resonance Measurements of Blood Flow and Tissue Perfusion Employing 2H2O as a Freely Diffusible Tracer

    Science.gov (United States)

    Ackerman, Joseph J. H.; Ewy, Coleen S.; Becker, Nancy N.; Shalwitz, Robert A.

    1987-06-01

    The use of deuterium oxide (2H2O) is proposed as a freely diffusible nuclear magnetic resonance (NMR) blood flow and tissue perfusion tracer of potential clinical utility. Deuterium is a stable, nonradiative isotope commercially available as 2H2O at enrichment levels of essentially 100%--i.e., 110 molar equivalent deuterium. This high concentration, together with the short relaxation time of the spin 1 (quadrupole) deuterium nuclide, provides substantial sensitivity for NMR spectroscopy. As a result, when 2H2O is administered in a bolus fashion to a specific tissue or organ in vivo, the deuterium NMR intensity time course can be analyzed, using mathematical models developed by others for radiolabeled tracers, to measure the rate of blood flow and tissue perfusion. Such an application is demonstrated herein at a static magnetic field of 8.5 tesla. Using single-compartment flow modeling, hepatic blood flow and tissue perfusion in fasted (18 hr) male Sprague-Dawley rats was determined to be 61 ± 17 (mean ± SD) ml/100 g per min (n = 5).

  15. Resonant interactions of perturbations in MHD flows

    Energy Technology Data Exchange (ETDEWEB)

    Sagalakov, A.M.; Shtern, V.N.

    1977-01-17

    The nonlinear theory of hydrodynamic stability differentiates three types of interactions: deformation of the initial velocity profile by Reynolds stress pulsations, multiplication of harmonics, and the resonant interaction of harmonics with dissimilar wave numbers and frequencies. This article analyzes an approach considering the first and third of these non-linear mechanisms, producing an acceptable approximation of the averaged characteristics of a developing pulsation movement, particularly the averaged turbulent velocity profile. The approach consists in analysis of triharmonic oscillations, the parameters of which satisfy the resonant relationships. A model of a triharmonic pulsation mode is studied which is applicable to MHD flows. It is shown in particular how a magnetic field transverse to the flow plane suppresses the resonant interaction of three-dimensional perturbations. This agrees with experimental studies on two-dimensional turbulence conducted earlier. 11 references, 3 figures.

  16. magnetic resonance imaging,etc.

    Institute of Scientific and Technical Information of China (English)

    张福基

    1998-01-01

    magnetic resonance imaging n.[1984] a noninvasive diagnostic technique that produces computerized images of internal body tissues and is based on nuclear magnetic resonance of atoms within he body induced by the application of radio waves磁共振成像(指一种非侵害 性诊断技术,能生成内部身体组织的计算机化影像,其依据是应用无线电波 感生体内原子并使之产磁共振)

  17. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... evaluate infections assess blood flow to the heart muscle evaluate findings following cardiovascular surgery In the abdominal ... a risk, depending on their nature and the strength of the MRI magnet. Many implanted devices will ...

  18. Development of a Semi-Automatic Technique for Flow Estimation using Optical Flow Registration and k-means Clustering on Two Dimensional Cardiovascular Magnetic Resonance Flow Images

    DEFF Research Database (Denmark)

    Brix, Lau; Christoffersen, Christian P. V.; Kristiansen, Martin Søndergaard

    of the aorta. Methods: 2D phase contrast flow images of the aorta were acquired from a patient with an enlarged pulmonary artery on a Philips Achieva 1.5T CMR system. The cardiac motion was removed from the data set using the Cornelius/Kanade registration algorithm. The time resolved flow data...... promising because it saves time for post-processing. However, the k-means cluster approach is not comprehensive for quantitative flow estimations as it is but seems feasible for a subsequent segmentation algorithm like deformable contours (i.e. snakes). Future work may overcome this manual part and make...

  19. Influence of pre-infarction angina, collateral flow, and pre-procedural TIMI flow on myocardial salvage index by cardiac magnetic resonance in patients with ST-segment elevation myocardial infarction

    DEFF Research Database (Denmark)

    Lønborg, Jacob Thomsen; Kelbæk, Henning Skov; Vejlstrup, Niels Grove

    2012-01-01

    BACKGROUND: In patients with ST-segment elevation myocardial infarction (STEMI) pre-infarction angina, pre-procedural TIMI flow and collateral flow to the myocardium supplied by the infarct related artery are suggested to be cardioprotective. We evaluated the effect of these factors on myocardial...... salvage index (MSI) and infarct size adjusting for area at risk in patients with STEMI treated with primary percutaneous coronary intervention. METHODS AND RESULTS: Cardiac magnetic resonance (CMR) was used to measure myocardial area at risk within 1-7 days and final infarct size 90±21 days after...

  20. Magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Bushong, S.C.

    1988-01-01

    This book introduces the fundamentals and principles of MRI, its capabilities and various techniques of application. Appropriate background for MRI is provided, including basic nuclear magnetic phenomena, modifications required for imaging, the current state of clinical knowledge and a survey of the future potential for in vivo MRI.

  1. Functionalized Magnetic Resonance Contrast Agent Selectively Binds to Glycoprotein IIb/IIIa on Activated Human Platelets under Flow Conditions and Is Detectable at Clinically Relevant Field Strengths

    Directory of Open Access Journals (Sweden)

    Constantin von zur Mühlen

    2008-03-01

    Full Text Available Recent progress in molecular magnetic resonance imaging (MRI provides the opportunity to image cells and cellular receptors using microparticles of iron oxide (MPIOs. However, imaging targets on vessel walls remains challenging owing to the quantity of contrast agents delivered to areas of interest under shear stress conditions. We evaluated ex vivo binding characteristics of a functional MRI contrast agent to ligand-induced binding sites (LIBSs on activated glycoprotein IIb/IIIa receptors of human platelets, which were lining rupture-prone atherosclerotic plaques and could therefore facilitate detection of platelet-mediated pathology in atherothrombotic disease. MPIOs were conjugated to anti-LIBS single-chain antibodies (LIBS-MPIO or control antibodies (control MPIO. Ex vivo binding to human platelet-rich clots in a dose-dependent manner was confirmed on a 3 T clinical MRI scanner and by histology (p < .05 for LIBS-MPIO vs control MPIO. By using a flow chamber setup, significant binding of LIBS-MPIO to a platelet matrix was observed under venous and arterial flow conditions, but not for control MPIO (p < .001. A newly generated MRI contrast agent detects activated human platelets at clinically relevant magnetic field strengths and binds to platelets under venous and arterial flow conditions, conveying high payloads of contrast to specific molecular targets. This may provide the opportunity to identify vulnerable, rupture-prone atherosclerotic plaques via noninvasive MRI.

  2. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... this is the case, you will be given instructions for your child about not eating or drinking several hours prior ... MRI) Safety Contrast Materials Children and Radiation Safety Videos related to Children’s (Pediatric) Magnetic Resonance Imaging Sponsored by Please note ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... of which shows a thin slice of the body. The images can then be studied from different angles by ... mail: Area code: Phone no: Thank you! ... Related Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain ...

  4. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... are the limitations of Children’s (Pediatric) MRI? What is Children’s (Pediatric) MRI? Magnetic resonance imaging (MRI) is ... ray, CT and ultrasound. top of page How is the procedure performed? MRI examinations may be performed ...

  5. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... E-mail: Area code: Phone no: Thank you! Images × Image Gallery Radiologist prepping patient for magnetic resonance imaging ( ... address): From (your name): Your e-mail address: Personal message (optional): Bees: Wax: Notice: RadiologyInfo respects your ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... E-mail: Area code: Phone no: Thank you! Images × Image Gallery Magnetic Resonance Imaging (MRI) procedure View full ... address): From (your name): Your e-mail address: Personal message (optional): Bees: Wax: Notice: RadiologyInfo respects your ...

  7. Magnetic Resonance Image Wavelet Enhancer

    Science.gov (United States)

    2007-11-02

    1Departamento de Ingenieria Electrica, UAM Iztapalapa, Mexico−DF, 09340, Mexico email:arog@xanum.uam.mx. Magnetic Resonance Centre, School of Physics...Number Task Number Work Unit Number Performing Organization Name(s) and Address(es) Departamento de Ingenieria Electrica, UAM Iztapalapa, Mexico-DF

  8. Evanescent Waves Nuclear Magnetic Resonance

    DEFF Research Database (Denmark)

    Halidi, El Mohamed; Nativel, Eric; Akel, Mohamad

    2016-01-01

    Nuclear Magnetic Resonance spectroscopy and imaging can be classified as inductive techniques working in the near- to far-field regimes. We investigate an alternative capacitive detection with the use of micrometer sized probes positioned at sub wavelength distances of the sample in order...

  9. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Magnetic Resonance ... allergic reaction than iodinated contrast material. Tell your doctor about any health problems, recent surgeries or allergies ...

  10. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. MRI ...

  11. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. MRI ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... structures of the brain and can also provide functional information (fMRI) in selected cases. MR images of ... Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain ...

  13. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose and treat medical ...

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose and treat medical ...

  15. Cardiovascular magnetic resonance: physics and terminology.

    Science.gov (United States)

    Rodgers, Christopher T; Robson, Matthew D

    2011-01-01

    Cardiovascular magnetic resonance (CMR) is the branch of magnetic resonance imaging (MRI) whose acquisition methods are adapted to surmount the particular challenges caused by motion of the heart and blood in vivo. Magnetic resonance imaging is supremely flexible; it can produce images showing the spatial distribution of diverse tissue characteristics, for example, proton density, T(1), T(2), T(2)(⁎), fat concentration, flow rate, and diffusion parameters. The image contrast may usefully be modified by intravenous infusion of contrast agents. Magnetic resonance imaging permits 2-dimensional or 3-dimensional acquisitions with arbitrary slice orientation. Unfortunately, MRI's flexibility is matched by a remarkable complexity not only in its fundamental principles but also in the optimization of applications in the clinic. This article attempts to demystify the basic principles of CMR and provides a primer on the terminology used in CMR. Complete confidence in the principles of CMR is not essential to use the technology. Nevertheless, knowledge of the principal terminology of MRI is a valuable first step when seeking to understand and apply modern methods in a clinical or research setting. Thus, the article closes with a glossary of terminology and references to high-quality educational resources. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. Advances in magnetic and optical resonance

    CERN Document Server

    Warren, Warren S

    1997-01-01

    Since 1965, Advances in Magnetic and Optical Resonance has provided researchers with timely expositions of fundamental new developments in the theory of, experimentation with, and application of magnetic and optical resonance.

  17. Intra- and inter-reader reproducibility of blood flow measurements on the ascending aorta and pulmonary artery using cardiac magnetic resonance.

    Science.gov (United States)

    Di Leo, Giovanni; D'Angelo, Ida Daniela; Alì, Marco; Cannaò, Paola Maria; Mauri, Giovanni; Secchi, Francesco; Sardanelli, Francesco

    2017-03-01

    The aim of our study was to estimate the intra- and inter-reader reproducibility of blood flow measurements in the ascending aorta and main pulmonary artery using cardiac magnetic resonance (CMR) and a semi-automated segmentation method. The ethics committee approved this retrospective study. A total of 50 consecutive patients (35 males and 15 females; mean age±standard deviation 27±13 years) affected by congenital heart disease were reviewed. They underwent CMR for flow analysis of the ascending aorta and main pulmonary artery (1.5 T, through-plane phase-contrast sequences). Two independent readers (R1, trained radiology resident; R2, lower-trained technician student) obtained segmented images twice (>10-day interval), using a semi-automated method of segmentation. Peak velocity, forward and backward flows were obtained. Bland-Altman analysis was used and reproducibility was reported as complement to 100% of the ratio between the coefficient of repeatability and the mean. R1 intra-reader reproducibility for the aorta was 99% (peak velocity), 95% (forward flow) and 49% (backward flow); for the pulmonary artery, 99%, 91% and 90%, respectively. R2 intra-reader reproducibility was 92%, 91% and 38%; 98%, 86% and 87%, respectively. Inter-reader reproducibility for the aorta was 91%, 85% and 20%; for the pulmonary artery 96%, 75%, and 82%, respectively. Our results showed a good to excellent reproducibility of blood flow measurements of CMR together with a semiautomated method of segmentation, for all variables except the backward flow of the ascending aorta, with a limited impact of operator's training.

  18. Parametric resonance induced chaos in magnetic damped driven pendulum

    Energy Technology Data Exchange (ETDEWEB)

    Khomeriki, Giorgi, E-mail: giokhomeriki123@gmail.com

    2016-07-15

    A damped driven pendulum with a magnetic driving force, appearing from a solenoid, where ac current flows is considered. The solenoid acts on the magnet, which is located at a free end of the pendulum. In this system the existence and interrelation of chaos and parametric resonance is theoretically examined. Derived analytical results are supported by numerical simulations and conducted experiments. - Highlights: • A damped magnetic pendulum is considered driven by off resonant magnetic field. • Our system is chaotic only when the conditions for parametric resonance are fulfilled. • Conducted experiments give a good agreement with theory and numerical simulations. • Calculated Lyapunov exponents are compared with parametric instability growth rates.

  19. Comparative Evaluation of Flow Quantification across the Atrioventricular Valve in Patients with Functional Univentricular Heart after Fontan's Surgery and Healthy Controls: Measurement by 4D Flow Magnetic Resonance Imaging and Streamline Visualization.

    Science.gov (United States)

    She, Hoi Lam; Roest, Arno A W; Calkoen, Emmeline E; van den Boogaard, Pieter J; van der Geest, Rob J; Hazekamp, Mark G; de Roos, Albert; Westenberg, Jos J M

    2017-01-01

    To evaluate the inflow pattern and flow quantification in patients with functional univentricular heart after Fontan's operation using 4D flow magnetic resonance imaging (MRI) with streamline visualization when compared with the conventional 2D flow approach. Seven patients with functional univentricular heart after Fontan's operation and twenty-three healthy controls underwent 4D flow MRI. In two orthogonal two-chamber planes, streamline visualization was applied, and inflow angles with peak inflow velocity (PIV) were measured. Transatrioventricular flow quantification was assessed using conventional 2D multiplanar reformation (MPR) and 4D MPR tracking the annulus and perpendicular to the streamline inflow at PIV, and they were validated with net forward aortic flow. Inflow angles at PIV in the patient group demonstrated wide variation of angles and directions when compared with the control group (P functional univentricular heart with previous Fontan's procedure. 4D flow aided generation of measurement planes according to the blood flood dynamics and has proven to be more accurate than the fixed plane 2D flow measurements when calculating flow quantifications. © 2016 Wiley Periodicals, Inc.

  20. Resonant magnetic fields from inflation

    CERN Document Server

    Byrnes, Christian T; Jain, Rajeev Kumar; Urban, Federico R

    2012-01-01

    We propose a novel scenario to generate primordial magnetic fields during inflation induced by an oscillating coupling of the electromagnetic field to the inflaton. This resonant mechanism has two key advantages over previous proposals. First of all, it generates a narrow band of magnetic fields at any required wavelength, thereby allaying the usual problem of a strongly blue spectrum and its associated backreaction. Secondly, it avoids the need for a strong coupling as the coupling is oscillating rather than growing or decaying exponentially. Despite these major advantages, we find that the backreaction is still far too large during inflation if the generated magnetic fields are required to have a strength of ${\\cal O}(10^{-15}\\, \\Gauss)$ today on observationally interesting scales. We provide a more general no-go argument, proving that this problem will apply to any model in which the magnetic fields are generated on subhorizon scales and freeze after horizon crossing.

  1. Magnetic resonance tomography in syringomyelia

    Energy Technology Data Exchange (ETDEWEB)

    Koehler, D.; Treisch, J.; Hertel, G.; Schoerner, W.; Fiegler, W.

    1985-12-01

    Thirteen patients with a clinical diagnosis of syringomyelia were examined by nuclear tomography (0.35 T magnet) in the spin-echo mode. In all thirteen patients, the T1 images (Se 400/35) showed a longitudinal cavity with a signal intensity of CSF. The shape and extent of the syrinx could be adequately demonstrated in 12 of the 13 examinations. Downward displacement of the cerebellar tonsils was seen in eight cases. The examination took between half and one hour. Advantages of magnetic resonance tomography (nuclear tomography) include the absence of artifacts, images in the line of the lesion and its non-invasiveness.

  2. Evanescent Waves Nuclear Magnetic Resonance

    DEFF Research Database (Denmark)

    Halidi, El Mohamed; Nativel, Eric; Akel, Mohamad

    2016-01-01

    Nuclear Magnetic Resonance spectroscopy and imaging can be classified as inductive techniques working in the near- to far-field regimes. We investigate an alternative capacitive detection with the use of micrometer sized probes positioned at sub wavelength distances of the sample in order to char...... a new road to a better understanding of the evanescent waves component in NMR with the opportunity to perform localized spectroscopy and imaging....

  3. Magnetic resonance and its applications

    CERN Document Server

    Chizhik, Vladimir I; Donets, Alexey V; Frolov, Vyacheslav V; Komolkin, Andrei V; Shelyapina, Marina G

    2014-01-01

    The book provides a basic understanding of the underlying theory, fundamentals and applications of magnetic resonance The book implies a few levels of the consideration (from simple to complex) of phenomena, that can be useful for different groups of readers The introductory chapter provides the necessary underpinning knowledge for newcomers to the methods The exposition of theoretical materials goes from initial to final formulas through detailed intermediate expressions.

  4. Volume Tracking: A new method for quantitative assessment and visualization of intracardiac blood flow from three-dimensional, time-resolved, three-component magnetic resonance velocity mapping

    Directory of Open Access Journals (Sweden)

    Arheden Håkan

    2011-04-01

    Full Text Available Abstract Background Functional and morphological changes of the heart influence blood flow patterns. Therefore, flow patterns may carry diagnostic and prognostic information. Three-dimensional, time-resolved, three-directional phase contrast cardiovascular magnetic resonance (4D PC-CMR can image flow patterns with unique detail, and using new flow visualization methods may lead to new insights. The aim of this study is to present and validate a novel visualization method with a quantitative potential for blood flow from 4D PC-CMR, called Volume Tracking, and investigate if Volume Tracking complements particle tracing, the most common visualization method used today. Methods Eight healthy volunteers and one patient with a large apical left ventricular aneurysm underwent 4D PC-CMR flow imaging of the whole heart. Volume Tracking and particle tracing visualizations were compared visually side-by-side in a visualization software package. To validate Volume Tracking, the number of particle traces that agreed with the Volume Tracking visualizations was counted and expressed as a percentage of total released particles in mid-diastole and end-diastole respectively. Two independent observers described blood flow patterns in the left ventricle using Volume Tracking visualizations. Results Volume Tracking was feasible in all eight healthy volunteers and in the patient. Visually, Volume Tracking and particle tracing are complementary methods, showing different aspects of the flow. When validated against particle tracing, on average 90.5% and 87.8% of the particles agreed with the Volume Tracking surface in mid-diastole and end-diastole respectively. Inflow patterns in the left ventricle varied between the subjects, with excellent agreement between observers. The left ventricular inflow pattern in the patient differed from the healthy subjects. Conclusion Volume Tracking is a new visualization method for blood flow measured by 4D PC-CMR. Volume Tracking

  5. Impairment of Coronary Flow Reserve Evaluated by Phase Contrast Cine-Magnetic Resonance Imaging in Patients With Heart Failure With Preserved Ejection Fraction.

    Science.gov (United States)

    Kato, Shingo; Saito, Naka; Kirigaya, Hidekuni; Gyotoku, Daiki; Iinuma, Naoki; Kusakawa, Yuka; Iguchi, Kohei; Nakachi, Tatsuya; Fukui, Kazuki; Futaki, Masaaki; Iwasawa, Tae; Kimura, Kazuo; Umemura, Satoshi

    2016-02-23

    Phase contrast (PC) cine-magnetic resonance imaging (MRI) of the coronary sinus allows for noninvasive evaluation of coronary flow reserve (CFR), which is an index of left ventricular microvascular function. The objective of this study was to investigate coronary flow reserve in patients with heart failure with preserved ejection fraction (HFpEF). We studied 25 patients with HFpEF (mean and SD of age: 73±7 years), 13 with hypertensive left ventricular hypertrophy (LVH) (67±10 years), and 18 controls (65±15 years). Breath-hold PC cine-MRI images of the coronary sinus were obtained to assess blood flow at rest and during ATP infusion. CFR was calculated as coronary sinus blood flow during ATP infusion divided by coronary sinus blood flow at rest. Impairment of CFR was defined as CFR <2.5 according to a previous study. The majority (76%) of HFpEF patients had decreased CFR. CFR was significantly decreased in HFpEF patients in comparison to hypertensive LVH patients and control subjects (CFR: 2.21±0.55 in HFpEF vs 3.05±0.74 in hypertensive LVH, 3.83±0.73 in controls; P<0.001 by 1-way ANOVA). According to multivariable linear regression analysis, CFR independently and significantly correlated with serum brain natriuretic peptide level (β=-68.0; 95% CI, -116.2 to -19.7; P=0.007). CFR was significantly lower in patients with HFpEF than in hypertensive LVH patients and controls. These results indicated that impairment of CFR might be a pathophysiological factor for HFpEF and might be related to HFpEF disease severity. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  6. Evaluation of tumor blood flow after feeder embolization in meningiomas by arterial spin-labeling perfusion magnetic resonance imaging.

    Science.gov (United States)

    Kawaji, Hiroshi; Koizumi, Shinichiro; Sakai, Naoto; Yamasaki, Tomohiro; Hiramatsu, Hisaya; Kanoko, Yusuke; Kamiya, Mika; Yamashita, Shuhei; Takehara, Yasuo; Sakahara, Harumi; Namba, Hiroki

    2013-10-01

    Preoperative embolization changes the amount of blood flow and pattern of flow distribution in meningioma. Tumor blood flow was investigated in eight meningioma patients before and after embolization using arterial spin-labeling (ASL) perfusion imaging. Although blood flow was significantly reduced in the whole tumor after embolization, changes in flow distribution patterns varied from one case to another. The findings suggest that evaluation of post-embolization tumor blood flow by ASL perfusion imaging would be useful in the surgical planning of meningioma.

  7. Advances in cardiac magnetic resonance imaging of congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Driessen, Mieke M.P. [University of Utrecht, University Medical Center Utrecht, Department of Radiology, PO Box 85500, Utrecht (Netherlands); University of Utrecht, University Medical Center Utrecht, Department of Cardiology, PO Box 85500, Utrecht (Netherlands); The Interuniversity Cardiology Institute of the Netherlands (ICIN) - Netherlands Heart Institute, PO Box 19258, Utrecht (Netherlands); Breur, Johannes M.P.J. [Wilhelmina Children' s Hospital, University Medical Center Utrecht, Department of Pediatric Cardiology, PO Box 85500, Utrecht (Netherlands); Budde, Ricardo P.J.; Oorschot, Joep W.M. van; Leiner, Tim [University of Utrecht, University Medical Center Utrecht, Department of Radiology, PO Box 85500, Utrecht (Netherlands); Kimmenade, Roland R.J. van; Sieswerda, Gertjan Tj [University of Utrecht, University Medical Center Utrecht, Department of Cardiology, PO Box 85500, Utrecht (Netherlands); Meijboom, Folkert J. [University of Utrecht, University Medical Center Utrecht, Department of Cardiology, PO Box 85500, Utrecht (Netherlands); Wilhelmina Children' s Hospital, University Medical Center Utrecht, Department of Pediatric Cardiology, PO Box 85500, Utrecht (Netherlands)

    2015-01-01

    Due to advances in cardiac surgery, survival of patients with congenital heart disease has increased considerably during the past decades. Many of these patients require repeated cardiovascular magnetic resonance imaging to assess cardiac anatomy and function. In the past decade, technological advances have enabled faster and more robust cardiovascular magnetic resonance with improved image quality and spatial as well as temporal resolution. This review aims to provide an overview of advances in cardiovascular magnetic resonance hardware and acquisition techniques relevant to both pediatric and adult patients with congenital heart disease and discusses the techniques used to assess function, anatomy, flow and tissue characterization. (orig.)

  8. Plasma-induced magnetic responses during nonlinear dynamics of magnetic islands due to resonant magnetic perturbations

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Seiya, E-mail: n-seiya@kobe-kosen.ac.jp [Kobe City College of Technology, Kobe, Hyogo 651-2194 (Japan)

    2014-12-15

    Resonant magnetic perturbations (RMPs) produce magnetic islands in toroidal plasmas. Self-healing (annihilation) of RMP-induced magnetic islands has been observed in helical systems, where a possible mechanism of the self-healing is shielding of RMP penetration by plasma flows, which is well known in tokamaks. Thus, fundamental physics of RMP shielding is commonly investigated in both tokamaks and helical systems. In order to check this mechanism, detailed informations of magnetic island phases are necessary. In experiments, measurement of radial magnetic responses is relatively easy. In this study, based on a theoretical model of rotating magnetic islands, behavior of radial magnetic fields during the self-healing is investigated. It is confirmed that flips of radial magnetic fields are typically observed during the self-healing. Such behavior of radial magnetic responses is also observed in LHD experiments.

  9. Effects of arterial blood flow on walls of the abdominal aorta: distributions of wall shear stress and oscillatory shear index determined by phase-contrast magnetic resonance imaging.

    Science.gov (United States)

    Sughimoto, Koichi; Shimamura, Yoshiaki; Tezuka, Chie; Tsubota, Ken'ichi; Liu, Hao; Okumura, Kenichiro; Masuda, Yoshitada; Haneishi, Hideaki

    2016-07-01

    Although abdominal aortic aneurysms (AAAs) occur mostly inferior to the renal artery, the mechanism of the development of AAA in relation to its specific location is not yet clearly understood. The objective of this study was to evaluate the hypothesis that even healthy volunteers may manifest specific flow characteristics of blood flow and alter wall shear or oscillatory shear stress in the areas where AAAs commonly develop. Eight healthy male volunteers were enrolled in this prospective study, aged from 24 to 27. Phase-contrast magnetic resonance imaging (MRI) was performed with electrocardiographic triggering. Flow-sensitive four-dimensional MR imaging of the abdominal aorta, with three-directional velocity encoding, including simple morphological image acquisition, was performed. Information on specific locations on the aortic wall was applied to the flow encodes to calculate wall shear stress (WSS) and oscillatory shear index (OSI). While time-framed WSS showed the highest peak of 1.14 ± 0.25 Pa in the juxtaposition of the renal artery, the WSS plateaued to 0.61 Pa at the anterior wall of the abdominal aorta. The OSI peaked distal to the renal arteries at the posterior wall of the abdominal aorta of 0.249 ± 0.148, and was constantly elevated in the whole abdominal aorta at more than 0.14. All subjects were found to have elevated OSI in regions where AAAs commonly occur. These findings indicate that areas of constant peaked oscillatory shear stress in the infra-renal aorta may be one of the factors that lead to morphological changes over time, even in healthy individuals.

  10. Experimental flow and perfusion measurement in an animal model with magnetic resonance tomography; Experimentelle Fluss- und Perfusionsmessungen im Tiermodell mit der Magnetresonanztomographie

    Energy Technology Data Exchange (ETDEWEB)

    Schoenberg, S.O.; Bock, M. [Deutsches Krebsforschungszentrum Heidelberg, Forschungsschwerpunkt Radiologische Diagnostik und Therapie (Germany); Just, A. [Inst. fuer Physiologie und Pathophysiologie, Univ. Heidelberg (Germany)

    2001-02-01

    Aim. Validation of non-invasive methods for morphologic and functional imaging of the kidney under physiologic and pathophysiologic conditions. Material and Methods. In chronically instrumented animals (foxhounds) comparative measurements of renal flow and perfusion were performed. Magnetic resonance imaging techniques were compared to data obtained from implanted flow probes and total kidney weight post mortem. In the MR system, different degrees of renal artery stenosis could be induced by means of an implanted inflatable cuff. The degree of stenosis was verified with high-resolution 3D contrast-enhanced MR angiography (3D-CE-MRA) using an intravascular contrast agent. Results. The MR-data agreed well with the invasively obtained results. Artifacts resulting from the implanted flow probes and other devices could be kept to a minimum due to appropriate selection of the probe materials and measurement strategies. Stenoses could be reproduced reliably and quantified from the induced morphologic and functional changes. Conclusion. Morphologic and functional MR techniques are well suited for non-invasive in vivo assessment of renal blood flow physiology. (orig.) [German] Ziel. Validierung von nichtinvasiven, morphologischen und funktionellen Magnetresonanzmethoden an der Niere unter physiologischen und pathophysiologischen Bedingungen. Material und Methode. Im chronisch instrumentierten Versuchstier (Foxhound) wurden vergleichende Messungen des Nierenarterienblutflusses und der parenchymalen Nierenperfusion durchgefuehrt. Dabei wurden die Magnetresonanzmessungen mit Daten eines implantierten Flussmesskopfes und dem autoptisch bestimmten Nierengewicht korreliert. Nierenarterienstenosen unterschiedlichen Grades konnten durch eine implantierte Manschette im Kernspintomographen waehrend der Messung induziert werden. Der Grad der induzierten Stenose wurde mit hochaufgeloesten MR-Angiographien unter Verwendung eines intravasalen Kontrastmittels verifiziert. Ergebnisse. Die

  11. Advances in magnetic resonance 3

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 3, describes a number of important developments which are finding increasing application by chemists. The book contains five chapters and begins with a discussion of how the properties of random molecular rotations reflect themselves in NMR and how they show up, often differently, in other kinds of experiments. This is followed by separate chapters on the Kubo method, showing its equivalence to the Redfield approach in the cases of most general interest; the current state of dynamic nuclear polarization measurements in solutions and what they tell us abou

  12. Systemic-to-pulmonary collateral flow in patients with palliated univentricular heart physiology: measurement using cardiovascular magnetic resonance 4D velocity acquisition

    Directory of Open Access Journals (Sweden)

    Valverde Israel

    2012-04-01

    Full Text Available Abstract Background Systemic-to-pulmonary collateral flow (SPCF may constitute a risk factor for increased morbidity and mortality in patients with single-ventricle physiology (SV. However, clinical research is limited by the complexity of multi-vessel two-dimensional (2D cardiovascular magnetic resonance (CMR flow measurements. We sought to validate four-dimensional (4D velocity acquisition sequence for concise quantification of SPCF and flow distribution in patients with SV. Methods 29 patients with SV physiology prospectively underwent CMR (1.5 T (n = 14 bidirectional cavopulmonary connection [BCPC], age 2.9 ± 1.3 years; and n = 15 Fontan, 14.4 ± 5.9 years and 20 healthy volunteers (age, 28.7 ± 13.1 years served as controls. A single whole-heart 4D velocity acquisition and five 2D flow acquisitions were performed in the aorta, superior/inferior caval veins, right/left pulmonary arteries to serve as gold-standard. The five 2D velocity acquisition measurements were compared with 4D velocity acquisition for validation of individual vessel flow quantification and time efficiency. The SPCF was calculated by evaluating the disparity between systemic (aortic minus caval vein flows and pulmonary flows (arterial and venour return. The pulmonary right to left and the systemic lower to upper body flow distribution were also calculated. Results The comparison between 4D velocity and 2D flow acquisitions showed good Bland-Altman agreement for all individual vessels (mean bias, 0.05±0.24 l/min/m2, calculated SPCF (−0.02±0.18 l/min/m2 and significantly shorter 4D velocity acquisition-time (12:34 min/17:28 min,p 2; Fontan 0.62±0.82 l/min/m2 and not in controls (0.01 + 0.16 l/min/m2, (3 inverse relation of right/left pulmonary artery perfusion and right/left SPCF (Pearson = −0.47,p = 0.01 and (4 upper to lower body flow distribution trend related to the weight (r = 0.742, p  Conclusions 4D

  13. Tunable Magnetic Resonance in Microwave Spintronics Devices

    Science.gov (United States)

    Chen, Yunpeng; Fan, Xin; Xie, Yunsong; Zhou, Yang; Wang, Tao; Wilson, Jeffrey D.; Simons, Rainee N.; Chui, Sui-Tat; Xiao, John Q.

    2015-01-01

    Magnetic resonance is one of the key properties of magnetic materials for the application of microwave spintronics devices. The conventional method for tuning magnetic resonance is to use an electromagnet, which provides very limited tuning range. Hence, the quest for enhancing the magnetic resonance tuning range without using an electromagnet has attracted tremendous attention. In this paper, we exploit the huge exchange coupling field between magnetic interlayers, which is on the order of 4000 Oe and also the high frequency modes of coupled oscillators to enhance the tuning range. Furthermore, we demonstrate a new scheme to control the magnetic resonance frequency. Moreover, we report a shift in the magnetic resonance frequency as high as 20 GHz in CoFe based tunable microwave spintronics devices, which is 10X higher than conventional methods.

  14. Magnetic resonance imaging of hemochromatosis arthropathy

    Energy Technology Data Exchange (ETDEWEB)

    Eustace, S. [Dept. of Radiology, Deaconess Hospital and Harvard Medical School, Boston, MA (United States); Buff, B. [Dept. of Radiology, Deaconess Hospital and Harvard Medical School, Boston, MA (United States); McCarthy, C. [The Inst. of Radiological Sciences, Mater Hospital, Dublin (Ireland); MacMathuana, P. [The Inst. of Radiological Sciences, Mater Hospital, Dublin (Ireland); Gilligan, P. [The Inst. of Radiological Sciences, Mater Hospital, Dublin (Ireland); Ennis, J.T. [The Inst. of Radiological Sciences, Mater Hospital, Dublin (Ireland)

    1994-10-01

    This study was undertaken to compare plain film radiography and magnetic resonance imaging in the assessment of hemochromatosis arthropathy of the knees of ten patients with a biopsy-proven diagnosis. Both modalities enabled visualisation of bony degenerative changes; magnetic resonance imaging enabled additional visualization of deformity of both cartilage and menisci. Magnetic resonance imaging failed reliably to confirm the presence of intra-articular iron in the patients studied. No correlation was observed between synovial fluid magnetic resonance signal values, corresponding serum ferritin levels, or the severity of the observed degenerative changes. (orig.)

  15. Noninvasive blood flow measurement and quantification of shunt volume by cine magnetic resonance in congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Sieverding, L.; Apitz, J. (Tuebingen Univ. (Germany). Abt. fuer Paediatrische Kardiologie); Jung, W.I. (Tuebingen Univ. (Germany). Abt. fuer Paediatrische Kardiologie Tuebingen Univ. (Germany). Physikalisches Inst.); Klose, U. (Tuebingen Univ. (Germany). Medizinisches Strahleninstitut und Roentgenabteilung)

    1992-04-01

    Based on the phase difference method as described by Nayler et al. we developed a gradient-echo sequence, which refocuses flow related phase shifts even for infants with their higher peak velocity, higher acceleration and faster heart rates. A repetition time (TR) of 15 ms provides a high temporal resolution for dynamic studies. Modification of the flow-rephasing gradient-echo sequence in slice select direction leads to a defined phase shift and the resultant phase difference images allow blood flow measurements in the great arteries and the calculation of blood volume per heart cycle (flow volume) to assess left and right ventricular stroke volume. This can also be achieved by calculation of the ventricular volume from contiguous slices of the whole heart, but, this in excessive measuring times. Both methods were applied in 6 examinations of children with congenital heart diseases (1 pulmonary sling, 1 coarctation of the aorta, 1 ventricular septal defect, 3 atrial septal defects). The age of the patients ranged from 3 months to 13.4 years (mean age 4.9 years). The regression analyses of both methods show a high correlation for systemic flow (y=-0.98+1.08 x, r=0.99, SEE=2.59 ml) and for pulmonary flow (y=-1.40+0.96 x, r=0.99, SEE=4.70 ml). The comparison of flow calculated Qp:Qs ratio and chamber size calculated Qp:Qs ratio with data obtained by heart catheterization show also a regression line close to the line of identity (y=-0.01+1.04 x, r=0.98, SEE=0.15 and y=0.28+0.96 x, r=0.81, SEE=0.47, respectively). (orig.).

  16. Magnetic resonance imaging of granular materials

    Science.gov (United States)

    Stannarius, Ralf

    2017-05-01

    Magnetic Resonance Imaging (MRI) has become one of the most important tools to screen humans in medicine; virtually every modern hospital is equipped with a Nuclear Magnetic Resonance (NMR) tomograph. The potential of NMR in 3D imaging tasks is by far greater, but there is only "a handful" of MRI studies of particulate matter. The method is expensive, time-consuming, and requires a deep understanding of pulse sequences, signal acquisition, and processing. We give a short introduction into the physical principles of this imaging technique, describe its advantages and limitations for the screening of granular matter, and present a number of examples of different application purposes, from the exploration of granular packing, via the detection of flow and particle diffusion, to real dynamic measurements. Probably, X-ray computed tomography is preferable in most applications, but fast imaging of single slices with modern MRI techniques is unmatched, and the additional opportunity to retrieve spatially resolved flow and diffusion profiles without particle tracking is a unique feature.

  17. Direction of flow in posterior communicating artery on magnetic resonance angiography in patients with occipital lobe infarcts

    NARCIS (Netherlands)

    Jongen, JCF; Franke, CL; Ramos, LMP; Wilmink, JT; van Gijn, J

    2004-01-01

    Background and Purpose - In some people the blood supply to the posterior cerebral artery occurs partly or even exclusively via the carotid system. This anatomic configuration may influence the risk of occipital lobe infarction. We studied the presence and direction of flow in the posterior communic

  18. Hemoglobin, hematocrit, and changes in cerebral blood flow : The Second Manifestations of ARTerial disease-Magnetic Resonance study

    NARCIS (Netherlands)

    van der Veen, Pieternella H.; Muller, Majon; Vincken, Koen L.; Westerink, Jan; Mali, Willem P. T. M.; van der Graaf, Yolanda; Geerlings, Mirjam I.; Doevendans, PAFM

    2015-01-01

    Hemoglobin and hematocrit are important determinants of blood viscosity and arterial oxygen content and may therefore influence cerebral blood flow (CBF). We examined cross-sectional and prospective associations of hemoglobin and hematocrit with CBF in 569 patients with manifest arterial disease (me

  19. Cerebral blood flow volume measurements of the carotid artery and ipsilateral branches using two-dimensional phase-contrast magnetic resonance angiography

    Institute of Scientific and Technical Information of China (English)

    Gang Guo; Yonggui Yang; Weiqun Yang

    2011-01-01

    The optimal velocity encoding of phase-contrast magnetic resonance angiography (PC MRA) in measuring cerebral blood flow volume (BFV) ranges from 60 to 80 cm/s. To verify the accuracy of two-dimensional (2D) PC MRA, the present study localized the region of interest at blood vessels of the neck using PC MRA based on three-dimensional time-of-flight sequences, and the velocity encodingwas set to 80 cm/s. Results of the measurements showed that the error rate was 7.0 ± 6.0%in the estimation of BFV in the internal carotid artery, the external carotid artery and the ipsilateralcommon carotid artery. There was no significant difference, and a significant correlation in BFV between internal carotid artery + external carotid artery and ipsilateral common carotid artery. Inaddition, the BFV of the common carotid artery was correlated with that of the ipsilateral internal carotid artery. The main error was attributed to the external carotid artery and its branches. Therefore,after selecting the appropriate scanning parameters and protocols, 2D PC MRA is more accuratein the determination of BFV in the carotid arteries.

  20. Regional and voxel-wise comparisons of blood flow measurements between dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) and arterial spin labeling (ASL) in brain tumors.

    Science.gov (United States)

    White, Carissa M; Pope, Whitney B; Zaw, Taryar; Qiao, Joe; Naeini, Kourosh M; Lai, Albert; Nghiemphu, Phioanh L; Wang, J J; Cloughesy, Timothy F; Ellingson, Benjamin M

    2014-01-01

    The objective of the current study was to evaluate the regional and voxel-wise correlation between dynamic susceptibility contrast (DSC) and arterial spin labeling (ASL) perfusion magnetic resonance imaging (MRI) measurement of cerebral blood flow (CBF) in patients with brain tumors. Thirty patients with histologically verified brain tumors were evaluated in the current study. DSC-MRI was performed by first using a preload dose of gadolinium contrast, then collecting a dynamic image acquisition during a bolus of contrast, followed by posthoc contrast agent leakage correction. Pseudocontinuous ASL was collected using 30 pairs of tag and control acquisition using a 3-dimensional gradient-echo spin-echo (GRASE) acquisition. All images were registered to a high-resolution anatomical atlas. Average CBF measurements within regions of contrast-enhancement and T2 hyperintensity were evaluated between the two modalities. Additionally, voxel-wise correlation between CBF measurements obtained with DSC and ASL were assessed. Results demonstrated a positive linear correlation between DSC and ASL measurements of CBF when regional average values were compared; however, a statistically significant voxel-wise correlation was only observed in around 30-40% of patients. These results suggest DSC and ASL may provide regionally similar, but spatially different measurements of CBF.

  1. Most water in the tomato truss is imported through the xylem, not the phloem: a nuclear magnetic resonance flow imaging study.

    Science.gov (United States)

    Windt, Carel W; Gerkema, Edo; Van As, Henk

    2009-10-01

    In this study, we demonstrate nuclear magnetic resonance flow imaging of xylem and phloem transport toward a developing tomato (Solanum lycopersicum) truss. During an 8-week period of growth, we measured phloem and xylem fluxes in the truss stalk, aiming to distinguish the contributions of the two transport tissues and draw up a balance between influx and efflux. It is commonly estimated that about 90% of the water reaches the fruit by the phloem and the remaining 10% by the xylem. The xylem is thought to become dysfunctional at an early stage of fruit development. However, our results do not corroborate these findings. On the contrary, we found that xylem transport into the truss remained functional throughout the 8 weeks of growth. During that time, at least 75% of the net influx into the fruit occurred through the external xylem and about 25% via the perimedullary region, which contains both phloem and xylem. About one-half of the net influx was lost due to evaporation. Halfway through truss development, a xylem backflow appeared. As the truss matured, the percentage of xylem water that circulated into the truss and out again increased in comparison with the net uptake, but no net loss of water from the truss was observed. The circulation of xylem water continued even after the fruits and pedicels were removed. This indicates that neither of them was involved in generating or conducting the circulation of sap. Only when the main axis of the peduncle was cut back did the circulation stop.

  2. New digital measurement methods for left ventricular volume using real-time three-dimensional echocardiography: comparison with electromagnetic flow method and magnetic resonance imaging

    Science.gov (United States)

    Qin, J. J.; Jones, M.; Shiota, T.; Greenberg, N. L.; Firstenberg, M. S.; Tsujino, H.; Zetts, A. D.; Sun, J. P.; Cardon, L. A.; Odabashian, J. A.; Flamm, S. D.; White, R. D.; Panza, J. A.; Thomas, J. D.

    2000-01-01

    AIM: The aim of this study was to investigate the feasibility and accuracy of using symmetrically rotated apical long axis planes for the determination of left ventricular (LV) volumes with real-time three-dimensional echocardiography (3DE). METHODS AND RESULTS: Real-time 3DE was performed in six sheep during 24 haemodynamic conditions with electromagnetic flow measurements (EM), and in 29 patients with magnetic resonance imaging measurements (MRI). LV volumes were calculated by Simpson's rule with five 3DE methods (i.e. apical biplane, four-plane, six-plane, nine-plane (in which the angle between each long axis plane was 90 degrees, 45 degrees, 30 degrees or 20 degrees, respectively) and standard short axis views (SAX)). Real-time 3DE correlated well with EM for LV stroke volumes in animals (r=0.68-0.95) and with MRI for absolute volumes in patients (r-values=0.93-0.98). However, agreement between MRI and apical nine-plane, six-plane, and SAX methods in patients was better than those with apical four-plane and bi-plane methods (mean difference = -15, -18, -13, vs. -31 and -48 ml for end-diastolic volume, respectively, Pmeasurement methods of real-time 3DE correlated well with reference standards for calculating LV volumes. Balancing accuracy and required time for these LV volume measurements, the apical six-plane method is recommended for clinical use.

  3. Four-dimensional visualization of thoracic blood flow by magnetic resonance imaging in a patient following correction of transposition of the great arteries (d-TGA) and uncorrected aortic coarctation.

    Science.gov (United States)

    Ley-Zaporozhan, J; Unterhinninghofen, R; Rengier, F; Markl, M; Eichhorn, J; von Tengg-Kobligk, H; Ley, S

    2009-10-01

    Recent advances in flow-sensitive magnetic resonance imaging (MRI) and data analysis allow for comprehensive noninvasive three-dimensional (3D) visualization of complex blood flow. Electrocardiogram (ECG)-gated three-directional (3dir) flow measurements were employed to assess and visualize time-resolved 3D blood flow in the pulmonary arteries (PA) and thoracic aorta. We present findings in a juvenile patient with surgically corrected transposition of the great arteries (d-TGA) and aortic coarctation. For the first time, the complex flow patterns in the PA following d-TGA were visualized. Morphologically, a slight asymmetry of the PA was found, with considerable impact on vascular hemodynamics, resulting in diastolic retrograde flow in the larger vessel and diastolic filling of the smaller PA. Additionally, increased flow to the supraaortic vessels was found due to aortic coarctation.

  4. Four-Dimensional Visualization of Thoracic Blood Flow by Magnetic Resonance Imaging in a Patient Following Correction of Transposition of the Great Arteries (d-TGA) and Uncorrected Aortic Coarctation

    Energy Technology Data Exchange (ETDEWEB)

    Ley-Zaporozhan, J.; Rengier, F.; Tengg-Kobligk, H. von (German Cancer Research Center (DKFZ) Heidelberg, Radiology, Heidelberg (Germany)); Ley, S.; Unterhinninghofen, R. (Univ. of Karlsruhe, Inst. of Computer Science and Engineering, Karlsruhe (Germany)); Markl, M. (Dept. of Diagnostic Radiology, Medical Physics, Univ. Hospital Freiburg, Freiburg (Germany)); Eichhorn, J. (Univ. Hospital, Pediatric Cardiology, Heidelberg (Germany))

    2009-10-15

    Recent advances in flow-sensitive magnetic resonance imaging (MRI) and data analysis allow for comprehensive noninvasive three-dimensional (3D) visualization of complex blood flow. Electrocardiogram (ECG)-gated three-directional (3dir) flow measurements were employed to assess and visualize time-resolved 3D blood flow in the pulmonary arteries (PA) and thoracic aorta. We present findings in a juvenile patient with surgically corrected transposition of the great arteries (d-TGA) and aortic coarctation. For the first time, the complex flow patterns in the PA following d-TGA were visualized. Morphologically, a slight asymmetry of the PA was found, with considerable impact on vascular hemodynamics, resulting in diastolic retrograde flow in the larger vessel and diastolic filling of the smaller PA. Additionally, increased flow to the supraaortic vessels was found due to aortic coarctation.

  5. Magnetic Resonance Imaging of Electrolysis.

    Science.gov (United States)

    Meir, Arie; Hjouj, Mohammad; Rubinsky, Liel; Rubinsky, Boris

    2015-01-01

    This study explores the hypothesis that Magnetic Resonance Imaging (MRI) can image the process of electrolysis by detecting pH fronts. The study has relevance to real time control of cell ablation with electrolysis. To investigate the hypothesis we compare the following MR imaging sequences: T1 weighted, T2 weighted and Proton Density (PD), with optical images acquired using pH-sensitive dyes embedded in a physiological saline agar solution phantom treated with electrolysis and discrete measurements with a pH microprobe. We further demonstrate the biological relevance of our work using a bacterial E. Coli model, grown on the phantom. The results demonstrate the ability of MRI to image electrolysis produced pH changes in a physiological saline phantom and show that these changes correlate with cell death in the E. Coli model grown on the phantom. The results are promising and invite further experimental research. PMID:25659942

  6. Pulmonary intravascular blood volume changes through the cardiac cycle in healthy volunteers studied by cardiovascular magnetic resonance measurements of arterial and venous flow

    Directory of Open Access Journals (Sweden)

    Arheden Hakan

    2009-10-01

    Full Text Available Abstract Background This study aims to present a novel method for using cardiovascular magnetic resonance (CMR to non-invasively quantify the variation in pulmonary blood volume throughout the cardiac cycle in humans. Methods 10 healthy volunteers (7 males, 3 female, age range 21-32 years were studied. The blood flow in the pulmonary artery and all pulmonary veins was quantified during free breathing using phase contrast velocity encoded CMR. The difference in flow between the pulmonary artery and the pulmonary veins was integrated to calculate the change in pulmonary blood volume throughout the cardiac cycle. Results The stroke volumes in the pulmonary artery and the sum of the pulmonary veins were (mean ± SEM 103 ± 6 ml and 95 ± 6 ml, respectively. The pulmonary blood volume variation (PBVV was 48 ± 5 ml, and the PBVV expressed as percent of the pulmonary artery stroke volume was 46 ± 3%. The maximum increase in pulmonary blood volume occurred 310 ± 12 ms after the R-wave from the ECG (32 ± 2% of the cardiac cycle. PBVV did not correlate to change in cross-sectional area in the pulmonary artery (R2 = 0.03, p = 0.66. Conclusion It is feasible to non-invasively quantify the change in pulmonary blood volume during the cardiac cycle in humans using CMR. The average pulmonary blood volume variation in healthy volunteers was approximately 50 ml and this was approximately 50% of the stroke volume. Further studies are needed to assess the utility of the pulmonary blood volume variation as a measure for identifying cardiac and pulmonary vascular disease.

  7. Cerebral blood flow in a healthy Circle of Willis and two intracranial aneurysms: computational fluid dynamics versus four-dimensional phase-contrast magnetic resonance imaging.

    Science.gov (United States)

    Berg, Philipp; Stucht, Daniel; Janiga, Gábor; Beuing, Oliver; Speck, Oliver; Thévenin, Dominique

    2014-04-01

    Computational fluid dynamics (CFD) opens up multiple opportunities to investigate the hemodynamics of the human vascular system. However, due to numerous assumptions the acceptance of CFD among physicians is still limited in practice and validation through comparison is mandatory. Time-dependent quantitative phase-contrast magnetic resonance imaging PC-MRI measurements in a healthy volunteer and two intracranial aneurysms were carried out at 3 and 7 Tesla. Based on the acquired images, three-dimensional (3D) models of the aneurysms were reconstructed and used for the numerical simulations. Flow information from the MR measurements were applied as boundary conditions. The four-dimensional (4D) velocity fields obtained by CFD and MRI were qualitatively as well as quantitatively compared including cut planes and vector analyses. For all cases a high similarity of the velocity patterns was observed. Additionally, the quantitative analysis revealed a good agreement between CFD and MRI. Deviations were caused by minor differences between the reconstructed vessel models and the actual lumen. The comparisons between diastole and systole indicate that relative differences between MRI and CFD are intensified with increasing velocity. The findings of this study lead to the conclusion that CFD and MRI agree well in predicting intracranial velocities when realistic geometries and boundary conditions are provided. Due to the considerably higher temporal and spatial resolution of CFD compared to MRI, complex flow patterns can be further investigated in order to evaluate their role with respect to aneurysm formation or rupture. Nevertheless, special care is required regarding the vessel reconstruction since the geometry has a major impact on the subsequent numerical results.

  8. DIFFERENTIATION OF AURANTII FRUCTUS IMMATURUS AND FRUCTUS PONICIRI TRIFOLIATAE IMMATURUS BY FLOW-INJECTION WITH ULTRAVIOLET SPECTROSCOPIC DETECTION AND PROTON NUCLEAR MAGNETIC RESONANCE USING PARTIAL LEAST-SQUARES DISCRIMINANT ANALYSIS.

    Science.gov (United States)

    Zhang, Mengliang; Zhao, Yang; Harrington, Peter de B; Chen, Pei

    2016-03-01

    Two simple fingerprinting methods, flow-injection coupled to ultraviolet spectroscopy and proton nuclear magnetic resonance, were used for discriminating between Aurantii fructus immaturus and Fructus poniciri trifoliatae immaturus. Both methods were combined with partial least-squares discriminant analysis. In the flow-injection method, four data representations were evaluated: total ultraviolet absorbance chromatograms, averaged ultraviolet spectra, absorbance at 193, 205, 225, and 283 nm, and absorbance at 225 and 283 nm. Prediction rates of 100% were achieved for all data representations by partial least-squares discriminant analysis using leave-one-sample-out cross-validation. The prediction rate for the proton nuclear magnetic resonance data by partial least-squares discriminant analysis with leave-one-sample-out cross-validation was also 100%. A new validation set of data was collected by flow-injection with ultraviolet spectroscopic detection two weeks later and predicted by partial least-squares discriminant analysis models constructed by the initial data representations with no parameter changes. The classification rates were 95% with the total ultraviolet absorbance chromatograms datasets and 100% with the other three datasets. Flow-injection with ultraviolet detection and proton nuclear magnetic resonance are simple, high throughput, and low-cost methods for discrimination studies.

  9. Functional Magnetic Resonance Imaging and Pediatric Anxiety

    Science.gov (United States)

    Pine, Daniel S.; Guyer, Amanda E.; Leibenluft, Ellen; Peterson, Bradley S.; Gerber, Andrew

    2008-01-01

    The use of functional magnetic resonance imaging in investigating pediatric anxiety disorders is studied. Functional magnetic resonance imaging can be utilized in demonstrating parallels between the neural architecture of difference in anxiety of humans and the neural architecture of attention-orienting behavior in nonhuman primates or rodents.…

  10. Chemical Principles Revisited. Proton Magnetic Resonance Spectroscopy.

    Science.gov (United States)

    McQuarrie, Donald A.

    1988-01-01

    Discusses how to interpret nuclear magnetic resonance (NMR) spectra and how to use them to determine molecular structures. This discussion is limited to spectra that are a result of observation of only the protons in a molecule. This type is called proton magnetic resonance (PMR) spectra. (CW)

  11. Enhancement of Magnetic Resonance Imaging with Metasurfaces

    NARCIS (Netherlands)

    Slobozhanyuk, Alexey P; Poddubny, Alexander N; Raaijmakers, AJE; van den Berg, CAT; Kozachenko, Alexander V; Dubrovina, Irina A; Melchakova, Irina V; Kivshar, Yuri S; Belov, Pavel A

    2016-01-01

    It is revealed that the unique properties of ultrathin metasurface resonators can improve magnetic resonance imaging dramatically. A metasurface formed when an array of metallic wires is placed inside a scanner under the studied object and a substantial enhancement of the radio-frequency magnetic

  12. Functional Magnetic Resonance Imaging and Pediatric Anxiety

    Science.gov (United States)

    Pine, Daniel S.; Guyer, Amanda E.; Leibenluft, Ellen; Peterson, Bradley S.; Gerber, Andrew

    2008-01-01

    The use of functional magnetic resonance imaging in investigating pediatric anxiety disorders is studied. Functional magnetic resonance imaging can be utilized in demonstrating parallels between the neural architecture of difference in anxiety of humans and the neural architecture of attention-orienting behavior in nonhuman primates or rodents.…

  13. Magnetic resonance imaging of the prostate

    DEFF Research Database (Denmark)

    Iversen, P; Kjaer, L; Thomsen, C

    1988-01-01

    Magnetic resonance imaging offers new possibilities in investigation of the prostate gland. Current results of imaging and tissue discrimination in the evaluation of prostatic disease are reviewed. Magnetic resonance imaging may be useful in the staging of carcinoma of the prostate....

  14. Magnetic resonance imaging of the prostate

    DEFF Research Database (Denmark)

    Iversen, P; Kjaer, L; Thomsen, C

    1987-01-01

    Magnetic resonance imaging offers new possibilities in the investigation of the prostate. The current results of imaging and tissue discrimination in the evaluation of prostatic disease are reviewed. Magnetic resonance imaging may be of value in the staging of carcinoma of the prostate....

  15. Intermodel Agreement of Myocardial Blood Flow Estimation From Stress-Rest Myocardial Perfusion Magnetic Resonance Imaging in Patients With Coronary Artery Disease

    NARCIS (Netherlands)

    Handayani, Astri; Triadyaksa, Pandji; Dijkstra, Hildebrand; Pelgrim, Gert Jan; van Ooijen, Peter M. A.; Prakken, Niek H. J.; Schoepf, U. Joseph; Oudkerk, Matthijs; Vliegenthart, Rozemarijn; Sijens, Paul E.

    2015-01-01

    Objectives: The aim of this study was to assess the intermodel agreement of different magnetic resonance myocardial perfusion models and evaluate their correspondence to stenosis diameter. Materials and Methods: In total, 260 myocardial segments were analyzed from rest and adenosine stress first-pas

  16. Quantification of aortic regurgitation by magnetic resonance velocity mapping

    DEFF Research Database (Denmark)

    Søndergaard, Lise; Lindvig, K; Hildebrandt, P

    1993-01-01

    The use of magnetic resonance (MR) velocity mapping in the quantification of aortic valvular blood flow was examined in 10 patients with angiographically verified aortic regurgitation. MR velocity mapping succeeded in identifying and quantifying the regurgitation in all patients, and the regurgit......The use of magnetic resonance (MR) velocity mapping in the quantification of aortic valvular blood flow was examined in 10 patients with angiographically verified aortic regurgitation. MR velocity mapping succeeded in identifying and quantifying the regurgitation in all patients......, and the regurgitant volume determined with MR velocity mapping agreed well with the grade obtained by aortic root angiography (p stroke volume (ml) measured by MR velocity mapping...

  17. A diffusion-weighted magnetic resonance imaging-based study of transcervical carotid stenting with flow reversal versus transfemoral filter protection.

    Science.gov (United States)

    Leal, Ignacio; Orgaz, Antonio; Flores, Ángel; Gil, Jose; Rodríguez, Rubén; Peinado, Javier; Criado, Enrique; Doblas, Manuel

    2012-12-01

    Transfemoral carotid artery stenting (CAS) has been associated with a high incidence of embolic phenomena and silent brain infarction. The goal of this study was to compare the incidence of new ischemic cerebral lesions on diffusion-perfusion magnetic resonance imaging (MRI) sequences after transcervical CAS performed with carotid flow reversal vs stenting via transfemoral approach with distal filter protection. During a 26-month period, 64 consecutive patients diagnosed with significant carotid stenosis by ultrasound imaging were assigned to transcervical CAS with carotid flow reversal or a transfemoral approach with a distal filter. The Rankin stroke scale was administered by an independent neurologist, and diffusion-weighted MRI (DW-MRI) studies were performed ≤24 hours before and ≤24 to 48 hours after the procedure. DW-MRI studies were compared by two neuroradiologists not involved in the study and blinded for time, clinical status, and treatment option. Hyperintense DW-MRI signals found after the procedure were interpreted as postoperative ischemic infarcts. All patients were assessed at 1, 6, and 12 months after the intervention. The distribution of demographic and pathologic variables was similar in both groups. All procedures were technically successful, with a mean carotid flow reversal time of 22 minutes. Twenty-one (70%) and 23 patients (69.69%) were symptomatic in the transcervical and transfemoral groups, respectively (P=.869). After intervention, new postprocedural DW-MRI ischemic infarcts were found in four transcervical (12.9%) and in 11 transfemoral (33.3%) patients (P=.03), without new neurologic symptoms. No major adverse events occurred at 30 days after the intervention. All patients remained neurologically intact, without an increase in stroke scale scoring. All stents remained patent, and all patients remained stroke-free during follow-up. In multivariate analysis, age (relative risk [RR], 1.022; Pfilter. The transcervical approach with

  18. Multidimensionally encoded magnetic resonance imaging.

    Science.gov (United States)

    Lin, Fa-Hsuan

    2013-07-01

    Magnetic resonance imaging (MRI) typically achieves spatial encoding by measuring the projection of a q-dimensional object over q-dimensional spatial bases created by linear spatial encoding magnetic fields (SEMs). Recently, imaging strategies using nonlinear SEMs have demonstrated potential advantages for reconstructing images with higher spatiotemporal resolution and reducing peripheral nerve stimulation. In practice, nonlinear SEMs and linear SEMs can be used jointly to further improve the image reconstruction performance. Here, we propose the multidimensionally encoded (MDE) MRI to map a q-dimensional object onto a p-dimensional encoding space where p > q. MDE MRI is a theoretical framework linking imaging strategies using linear and nonlinear SEMs. Using a system of eight surface SEM coils with an eight-channel radiofrequency coil array, we demonstrate the five-dimensional MDE MRI for a two-dimensional object as a further generalization of PatLoc imaging and O-space imaging. We also present a method of optimizing spatial bases in MDE MRI. Results show that MDE MRI with a higher dimensional encoding space can reconstruct images more efficiently and with a smaller reconstruction error when the k-space sampling distribution and the number of samples are controlled.

  19. Nuclear magnetic resonance studies of the solvation structures of a high-performance nonaqueous redox flow electrolyte

    Science.gov (United States)

    Deng, Xuchu; Hu, Mary; Wei, Xiaoliang; Wang, Wei; Mueller, Karl T.; Chen, Zhong; Hu, Jian Zhi

    2016-03-01

    Understanding the solvation structures of electrolytes is important for developing nonaqueous redox flow batteries that hold considerable potential for future large scale energy storage systems. The utilization of an emerging ionic-derivatived ferrocene compound, ferrocenylmethyl dimethyl ethyl ammonium bis(trifluoromethanesulfonyl)imide (Fc1N112-TFSI), has recently overcome the issue of solubility in the supporting electrolyte. In this work, 13C, 1H and 17O NMR investigations were carried out using electrolyte solutions consisting of Fc1N112-TFSI as the solute and the mixed alkyl carbonate as the solvent. It was observed that the spectra of 13C experience changes of chemical shifts while those of 17O undergo linewidth broadening, indicating interactions between solute and solvent molecules. Quantum chemistry calculations of both molecular structures and chemical shifts (13C, 1H and 17O) are performed for interpreting experimental results and for understanding the detailed solvation structures. The results indicate that Fc1N112-TFSI is dissociated at varying degrees in mixed solvent depending on concentrations. At dilute solute concentrations, most Fc1N112+ and TFSI- are fully disassociated with their own solvation shells formed by solvent molecules. At saturated concentration, Fc1N112+-TFSI- contact ion pairs are formed and the solvent molecules are preferentially interacting with the Fc rings rather than interacting with the ionic pendant arm of Fc1N112-TFSI.

  20. Magnetic Resonance Imaging Quantification of Regional Cerebral Blood Flow and Cerebrovascular Reactivity to Carbon Dioxide in Normotensive and Hypertensive Rats

    Science.gov (United States)

    Leoni, Renata F.; Paiva, Fernando F.; Henning, Erica C.; Nascimento, George C.; Tannús, Alberto; de Araujo, Draulio B.; Silva, Afonso C.

    2011-01-01

    Hypertension afflicts 25% of the general population and over 50% of the elderly. In the present work, arterial spin labeling MRI was used to non-invasively quantify regional cerebral blood flow (CBF), cerebrovascular resistance and CO2 reactivity in spontaneously hypertensive rats (SHR) and in normotensive Wistar Kyoto rats (WKY), at two different ages (3 months and 10 months) and under the effects of two anesthetics, α-chloralose and 2% isoflurane (1.5 MAC). Repeated CBF measurements were highly consistent, differing by less than 10% and 18% within and across animals, respectively. Under α-chloralose, whole brain CBF at normocapnia did not differ between groups (young WKY: 61±3ml/100g/min; adult WKY: 62±4ml/100g/min; young SHR: 70±9ml/100g/min; adult SHR: 69±8ml/100g/min), indicating normal cerebral autoregulation in SHR. At hypercapnia, CBF values increased significantly, and a linear relationship between CBF and PaCO2 levels was observed. In contrast, 2% isoflurane impaired cerebral autoregulation. Whole brain CBF in SHR was significantly higher than in WKY rats at normocapnia (young SHR: 139±25ml/100g/min; adult SHR: 104±23ml/100g/min; young WKY: 55±9ml/100g/min; adult WKY: 71±19ml/100g/min). CBF values increased significantly with increasing CO2; however, there was a clear saturation of CBF at PaCO2 levels greater than 70 mmHg in both young and adult rats, regardless of absolute CBF values, suggesting that isoflurane interferes with the vasodilatory mechanisms of CO2. This behavior was observed for both cortical and subcortical structures. Under either anesthetic, CO2 reactivity values in adult SHR were decreased, confirming that hypertension, when combined with age, increases cerebrovascular resistance and reduces cerebrovascular compliance. PMID:21708273

  1. Nuclear magnetic resonance system with continuous flow of polarized water to obtain the traceability to static magnetic fields; Sistema de ressonancia magnetica nuclear com fluxo continuo de agua polarizada para obtencao da rastreabilidade para campos magneticos estaticos

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Ramon Valls; Nazarre, Diego Joriro, E-mail: ramon@ipt.br [Instituto de Pesquisas Tecnologicas (IPT), Sao Paulo, SP (Brazil)

    2013-07-01

    We have developed a system to obtain the traceability of field or magnetic induction intensity in the range of 2 μT up to 2 T, even in the presence of magnetic field gradients or noisy environments. The system is based on a nuclear magnetic resonance magnetometer, built in streaming water. The calibration procedure of a coil for magnetic field generation is described, as well as the results obtained and the estimated uncertainty (author)

  2. A novel method of combining blood oxygenation and blood flow sensitive magnetic resonance imaging techniques to measure the cerebral blood flow and oxygen metabolism responses to an unknown neural stimulus.

    Science.gov (United States)

    Simon, Aaron B; Griffeth, Valerie E M; Wong, Eric C; Buxton, Richard B

    2013-01-01

    Simultaneous implementation of magnetic resonance imaging methods for Arterial Spin Labeling (ASL) and Blood Oxygenation Level Dependent (BOLD) imaging makes it possible to quantitatively measure the changes in cerebral blood flow (CBF) and cerebral oxygen metabolism (CMRO(2)) that occur in response to neural stimuli. To date, however, the range of neural stimuli amenable to quantitative analysis is limited to those that may be presented in a simple block or event related design such that measurements may be repeated and averaged to improve precision. Here we examined the feasibility of using the relationship between cerebral blood flow and the BOLD signal to improve dynamic estimates of blood flow fluctuations as well as to estimate metabolic-hemodynamic coupling under conditions where a stimulus pattern is unknown. We found that by combining the information contained in simultaneously acquired BOLD and ASL signals through a method we term BOLD Constrained Perfusion (BCP) estimation, we could significantly improve the precision of our estimates of the hemodynamic response to a visual stimulus and, under the conditions of a calibrated BOLD experiment, accurately determine the ratio of the oxygen metabolic response to the hemodynamic response. Importantly we were able to accomplish this without utilizing a priori knowledge of the temporal nature of the neural stimulus, suggesting that BOLD Constrained Perfusion estimation may make it feasible to quantitatively study the cerebral metabolic and hemodynamic responses to more natural stimuli that cannot be easily repeated or averaged.

  3. A novel method of combining blood oxygenation and blood flow sensitive magnetic resonance imaging techniques to measure the cerebral blood flow and oxygen metabolism responses to an unknown neural stimulus.

    Directory of Open Access Journals (Sweden)

    Aaron B Simon

    Full Text Available Simultaneous implementation of magnetic resonance imaging methods for Arterial Spin Labeling (ASL and Blood Oxygenation Level Dependent (BOLD imaging makes it possible to quantitatively measure the changes in cerebral blood flow (CBF and cerebral oxygen metabolism (CMRO(2 that occur in response to neural stimuli. To date, however, the range of neural stimuli amenable to quantitative analysis is limited to those that may be presented in a simple block or event related design such that measurements may be repeated and averaged to improve precision. Here we examined the feasibility of using the relationship between cerebral blood flow and the BOLD signal to improve dynamic estimates of blood flow fluctuations as well as to estimate metabolic-hemodynamic coupling under conditions where a stimulus pattern is unknown. We found that by combining the information contained in simultaneously acquired BOLD and ASL signals through a method we term BOLD Constrained Perfusion (BCP estimation, we could significantly improve the precision of our estimates of the hemodynamic response to a visual stimulus and, under the conditions of a calibrated BOLD experiment, accurately determine the ratio of the oxygen metabolic response to the hemodynamic response. Importantly we were able to accomplish this without utilizing a priori knowledge of the temporal nature of the neural stimulus, suggesting that BOLD Constrained Perfusion estimation may make it feasible to quantitatively study the cerebral metabolic and hemodynamic responses to more natural stimuli that cannot be easily repeated or averaged.

  4. Resting myocardial blood flow quantification using contrast-enhanced magnetic resonance imaging in the presence of stenosis: A computational fluid dynamics study

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, Karsten, E-mail: sommerk@uni-mainz.de, E-mail: Schreiber-L@ukw.de [Section of Medical Physics, Department of Radiology, Johannes Gutenberg University Medical Center, Mainz 55131, Germany and Max Planck Graduate Center with the Johannes Gutenberg University Mainz, Mainz 55128 (Germany); Bernat, Dominik; Schmidt, Regine; Breit, Hanns-Christian [Section of Medical Physics, Department of Radiology, Johannes Gutenberg University Medical Center, Mainz 55131 (Germany); Schreiber, Laura M., E-mail: sommerk@uni-mainz.de, E-mail: Schreiber-L@ukw.de [Comprehensive Heart Failure Center, Department of Cardiovascular Imaging, Würzburg University Hospital, Würzburg 97078 (Germany)

    2015-07-15

    Purpose: The extent to which atherosclerotic plaques affect contrast agent (CA) transport in the coronary arteries and, hence, quantification of myocardial blood flow (MBF) using magnetic resonance imaging (MRI) is unclear. The purpose of this work was to evaluate the influence of plaque induced stenosis both on CA transport and on the accuracy of MBF quantification. Methods: Computational fluid dynamics simulations in a high-detailed realistic vascular model were employed to investigate CA bolus transport in the coronary arteries. The impact of atherosclerosis was analyzed by inserting various medium- to high-grade stenoses in the vascular model. The influence of stenosis morphology was examined by varying the stenosis shapes but keeping the area reduction constant. Errors due to CA bolus transport were analyzed using the tracer-kinetic model MMID4. Results: Dispersion of the CA bolus was found in all models and for all outlets, but with a varying magnitude. The impact of stenosis was complex: while high-grade stenoses amplified dispersion, mild stenoses reduced the effect. Morphology was found to have a marked influence on dispersion for a small number of outlets in the post-stenotic region. Despite this marked influence on the concentration–time curves, MBF errors were less affected by stenosis. In total, MBF was underestimated by −7.9% to −44.9%. Conclusions: The presented results reveal that local hemodynamics in the coronary vasculature appears to have a direct impact on CA bolus dispersion. Inclusion of atherosclerotic plaques resulted in a complex alteration of this effect, with both degree of area reduction and stenosis morphology affecting the amount of dispersion. This strong influence of vascular transport effects impairs the accuracy of MRI-based MBF quantification techniques and, potentially, other bolus-based perfusion measurement techniques like computed tomography perfusion imaging.

  5. Study of cerebral blood flow by magnetic resonance 0. 5 T. Estudio de la perfusion cerebral con RM de 0,5 T

    Energy Technology Data Exchange (ETDEWEB)

    Torrijo, C.; Marti-Bonmati, L.; Palop, C.; Caballero, E.; Poyatos, C.; Sopena, R. (Hospital Doctor Peset. Servicio de Diagnostico por la Imagen. Valencia (Spain))

    1993-01-01

    To asses the cerebral blood flow by magnetic resonance, 1.5 T superconductor imagers have been used, taking slices of the brain for dynamic study following rapid iv administration of gadolinium (Gd-DTPA). Our aim was to attempt to reproduce these data with a 0.5 T superconductor imager. Thirty-two dynamic studies of the head were carried out. The first 10 were used to modify the methodology until a standard technique was achieved, which was employed for the remaining 22:T2*-weighted gradient-echo sequence (TR=50msec, TE=23 msec, angle=10*, thickness=10mm, matrix=128x64, FOV=250 mm), taking 15 slices in 75 seconds following a 20 ml iv bolus of Gd-DTPA. When the signal intensity was measured at the level of the cerebral cortex, a reduction was detected in association with the passage of Gd-DTPA through the cerebral microcirculation, with a mean signal loss of 5.96%[+-]2.25. This signal loss is significant (p<0.01) when compared with that reported in studies in which no contrast agent was used (2.54%[+-]0.6). The maximum signal loss appeared at times varying between 10 and 40 seconds after administration of the contrast medium. It is concluded that passage (perfusion) through the cerebral microcirculation can be observed at 0.5 T, although the attenuation values obtained are lower than those reported by other authors in their series. The time at which the signal loss appears after iv contrast administration is unpredictable, fact which further limits the utility of this methodology. (Author)

  6. Attempts to Improve Absolute Quantification of Cerebral Blood Flow in Dynamic Susceptibility Contrast Magnetic Resonance Imaging: A Simplified T1-Weighted Steady-State Cerebral Blood Volume Approach

    Energy Technology Data Exchange (ETDEWEB)

    Wirestam, R.; Knutsson, L.; Risberg, J.; Boerjesson, S.; Larsson, E.M.; Gustafson, L.; Passant, U.; Staahlberg, F. [Depts. of Medical Radiation Physics, Diagnostic Radiology, Psychiatry, and Psychogeriatrics, Lund Univ, Lund (Sweden)

    2007-07-15

    Background: Attempts to retrieve absolute values of cerebral blood flow (CBF) by dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) have typically resulted in overestimations. Purpose: To improve DSC-MRI CBF estimates by calibrating the DSC-MRI-based cerebral blood volume (CBV) with a corresponding T1-weighted (T1W) steady-state (ss) CBV estimate. Material and Methods: 17 volunteers were investigated by DSC-MRI and 133Xe SPECT. Steady-state CBV calculation, assuming no water exchange, was accomplished using signal values from blood and tissue, before and after contrast agent, obtained by T1W spin-echo imaging. Using steady-state and DSC-MRI CBV estimates, a calibration factor K = CBV(ss)/CBV(DSC) was obtained for each individual. Average whole-brain CBF(DSC) was calculated, and the corrected MRI-based CBF estimate was given by CBF(ss) = KxCBF(DSC). Results: Average whole-brain SPECT CBF was 40.1{+-}6.9 ml/min 100 g, while the corresponding uncorrected DSC-MRI-based value was 69.2{+-}13.8 ml/mi 100 g. After correction with the calibration factor, a CBF(ss) of 42.7{+-}14.0 ml/min 100 g was obtained. The linear fit to CBF(ss)-versus-CBF(SPECT) data was close to proportionality (R = 0.52). Conclusion: Calibration by steady-state CBV reduced the population average CBF to a reasonable level, and a modest linear correlation with the reference 133Xe SPECT technique was observed. Possible explanations for the limited accuracy are, for example, large-vessel partial-volume effects, low post-contrast signal enhancement in T1W images, and water-exchange effects.

  7. Fully automated quantification of regional cerebral blood flow with three-dimensional stereotaxic region of interest template. Validation using magnetic resonance imaging. Technical note

    Energy Technology Data Exchange (ETDEWEB)

    Takeuchi, Ryo; Katayama, Shigenori; Takeda, Naoya; Fujita, Katsuzo [Nishi-Kobe Medical Center (Japan); Yonekura, Yoshiharu [Fukui Medical Univ., Matsuoka (Japan); Konishi, Junji [Kyoto Univ. (Japan). Graduate School of Medicine

    2003-03-01

    The previously reported three-dimensional stereotaxic region of interest (ROI) template (3DSRT-t) for the analysis of anatomically standardized technetium-99m-L,L-ethyl cysteinate dimer ({sup 99m}Tc-ECD) single photon emission computed tomography (SPECT) images was modified for use in a fully automated regional cerebral blood flow (rCBF) quantification software, 3DSRT, incorporating an anatomical standardization engine transplanted from statistical parametric mapping 99 and ROIs for quantification based on 3DSRT-t. Three-dimensional T{sub 2}-weighted magnetic resonance images of 10 patients with localized infarcted areas were compared with the ROI contour of 3DSRT, and the positions of the central sulcus in the primary sensorimotor area were also estimated. All positions of the 20 lesions were in strict accordance with the ROI delineation of 3DSRT. The central sulcus was identified on at least one side of 210 paired ROIs and in the middle of 192 (91.4%) of these 210 paired ROIs among the 273 paired ROIs of the primary sensorimotor area. The central sulcus was recognized in the middle of more than 71.4% of the ROIs in which the central sulcus was identifiable in the respective 28 slices of the primary sensorimotor area. Fully automated accurate ROI delineation on anatomically standardized images is possible with 3DSRT, which enables objective quantification of rCBF and vascular reserve in only a few minutes using {sup 99m}Tc-ECD SPECT images obtained by the resting and vascular reserve (RVR) method. (author)

  8. Nuclear magnetic resonance. Tomography of tomorrow

    Energy Technology Data Exchange (ETDEWEB)

    Ethier, R.; Melanson, D.; Peters, T.M. (Montreal Neurological Inst., Quebec (Canada))

    1983-10-01

    Ten years following computerized tomography, a new technique called nuclear magnetic resonance revolutionizes the field of diagnostic imaging. A major advantage of nuclear magnetic resonance is that the danger of radiation is non-existent as compared to computerized tomography. When parts of the human body are subject to radio-frequencies while in a fixed magnetic field, its most detailed structures are revealed. The quality of images, the applications, as well as the indications are forever increasing. Images obtained at the level of the brain and spinal cord through nuclear magnetic resonance supercede those obtained through computerized tomography. Hence, it is most likely that myelography, along with pneumoencephalography will be eliminated as a diagnostic means. It is without a doubt that nuclear magnetic resonance is tomorrow's computerized tomography.

  9. Use of magnetic resonance urography.

    Science.gov (United States)

    Klein, L T; Frager, D; Subramanium, A; Lowe, F C

    1998-10-01

    Magnetic resonance urography (MRU) is a new technique that uses heavily weighted T2 coronal images with fat suppression pulse. Urine appears white on MRU, resembling an intravenous urogram (IVU). Contrast agents are not necessary. This study describes the use of MRU in the diagnosis and treatment of patients with hematuria. One hundred six patients with microscopic or gross hematuria and 6 normal volunteers underwent MRU between 1992 and 1995. A modified, heavily weighted T2 technique with intravenous administration of furosemide and ureteral compression was used. Thirty-two patients had other imaging techniques as well for comparison. MRU provided high-resolution images in almost all cases; 73 (69%) had a normal MRU. Significant findings in the 33 patients with abnormalities included renal cysts in 17 (51%), renal cell carcinoma in 6 (18%), transitional cell carcinoma in 5 (15%), ureteropelvic junction obstruction in 3 (9%), and stones causing obstruction in 6 (18%). Five patients with renal failure also had good visualization of the entire urinary tract. MRU was comparable to other imaging modalities except in identifying nonobstructing calculi. MRU provides an alternative to conventional imaging of the urinary tract, especially in those patients who have contraindications to ionizing radiation and contrast agents. Improvements in resolution, technique, and cost have to be addressed before it can be used regularly in urologic practice.

  10. Magnetic resonance images of hematospermia

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, Norio; Miki, Kenta; Kato, Nobuki; Furuta, Nozomu; Ohishi, Yukihiko [Jikei Univ., Tokyo (Japan). School of Medicine; Kondo, Naoya; Tashiro, Kazuya

    1998-12-01

    We performed MRI (magnetic resonance imaging) in the pelvic region of 70 cases with hematospermia and conducted a study on the abnormal MRI findings to which hematospermia could be attributed. We conducted a study on the morphological anomaly and change in the signal intensity in the prostate gland and of the seminal vesicle as well as on the presence or absence of dilation in the plexus venous surrounding the deferent duct or the prostate gland out of the abnormal MRI findings. As for the seminal vesicle, the patients whose seminal vesicle was seen in higher intensity than the prostate gland in T1 weighted images were diagnosed as having hemorrhagic focus and the patients whose seminal vesicle was seen in low intensity both in T1 and T2 weighted images were diagnosed as having fibrosis caused by chronic inflammation. Abnormal MRI findings were seen in 40 out of the 70 cases (57%). Anomaly in the prostate gland was indicated in 6 (9%) cases. Abnormality in the seminal vesicle was indicated in 30 cases (43%) including hemorrhage of seminal vesicle in 25 cases, chronic inflammation in five cases and cyst of seminal vesicle in one case. In conducting an examination of the patients with hematospermia, MRI is the nonivasive and reproducible method and it is possible to identify the hemorrhagic region. Therefore, MRI is thought to be useful to identify the causal organs of hematospermia. (author)

  11. Aortic dissection: magnetic resonance imaging.

    Science.gov (United States)

    Amparo, E G; Higgins, C B; Hricak, H; Sollitto, R

    1985-05-01

    Fifteen patients with suspected or known aortic dissection were imaged with magnetic resonance (MR). Thirteen of these patients were eventually shown to have dissection. In most instances the diagnosis was established by aortography and/or computed tomography (CT) prior to the MR study. Surgical proof (6/13) and/or aortographic proof (10/13) were available in 11/13 patients with aortic dissection. MR demonstrated the intimal flap and determined whether the dissection was type A or type B. In addition, MR: differentiated between the true and false lumens; determined the origins of the celiac, superior mesenteric, and renal arteries from the true or false lumen in the cases where the dissection extended into the abdominal aorta (8/12); allowed post-surgical surveillance of the dissection; and identified aortoannular ectasia in the three patients who had Marfan syndrome. In addition to the 13 cases with dissection, there were two cases in whom the diagnosis of dissection was excluded by MR. Our early experience suggests that MR can serve as the initial imaging test in clinically suspected cases of aortic dissection and that the information provided by MR is sufficient to manage many cases. Additionally, MR obviates the use of iodinated contrast media.

  12. Magnetic resonance in Multiple Sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Scotti, G.; Scialfa, G.; Biondi, A.; Landoni, L.; Caputo, D.; Cazzullo, C.L.

    1986-07-01

    Magnetic Resonance Imaging was performed in more than 200 patients with clinical suspicion or knowledge of Multiple Sclerosis. One hundred and forty-seven (60 males and 87 females) had MR evidence of multiple sclerosis lesions. The MR signal of demyelinating plaques characteristically has prolonged T1 and T2 relaxation times and the T2-weighted spin-echo sequences are generally superior to the T1-weighted images because the lesions are better visualized as areas of increased signal intensity. MR is also able to detect plaques in the brainstem, cerebellum and within the cervical spinal cord. MR appears to be an important, non-invasive method for the diagnosis of Multiple Sclerosis and has proven to be diagnostically superior to CT, evoked potentials (EP) and CSF examination. In a selected group of 30 patients, with the whole battery of the relevant MS studies, MR was positive in 100%, CT in 33,3%, EP in 56% and CSF examination in 60%. In patients clinically presenting only with signs of spinal cord involvement or optic neuritis or when the clinical presentation is uncertain MR has proven to be a very useful diagnostic tool for diagnosis of MS by demonstrating unsuspected lesions in the cerebral hemispheres.

  13. Magnetic resonance imaging of the heart.

    Science.gov (United States)

    Tscholakoff, D; Higgins, C B

    1985-01-01

    Magnetic resonance imaging (MRI) is a completely noninvasive technique for the evaluation of the cardiovascular system. With a multi-section technique and the spin echo pulse sequence the entire heart can be examined within six to ten minutes. All our cardiac MR studies were performed with electrocardiographic (ECG) gating, to obtain adequate resolution of the cardiac structures. With this technique, patients and animals with a variety of cardiac abnormalities were studied. The examined pathologic conditions included acute and chronic myocardial infarctions and their complications, hypertrophic and congestive cardiomyopathies, congenital heart diseases and pericardial diseases. MRI offers an enormous potential for cardiovascular diagnosis, even beyond the demonstration of pathoanatomy, because of the capability for direct tissue characterization and blood flow measurements.

  14. A Magnetic Resonance Measurement Technique for Rapidly Switched Gradient Magnetic Fields in a Magnetic Resonance Tomograph

    Directory of Open Access Journals (Sweden)

    K. Bartušek

    2003-01-01

    Full Text Available This paper describes a method for measuring of the gradient magnetic field in Nuclear Magnetic Resonance (NMR tomography, which is one of the modern medical diagnostic methods. A very important prerequisite for high quality imaging is a gradient magnetic field in the instrument with exactly defined properties. Nuclear magnetic resonance enables us to measure the pulse gradient magnetic field characteristics with high accuracy. These interesting precise methods were designed, realised, and tested at the Institute of Scientific Instruments (ISI of the Academy of Sciences of the Czech Republic. The first of them was the Instantaneous Frequency (IF method, which was developed into the Instantaneous Frequency of Spin Echo (IFSE and the Instantaneous Frequency of Spin Echo Series (IFSES methods. The above named methods are described in this paper and their a comparison is also presented.

  15. Magnetic Resonance Microscopy of Flows and Compressions of the Circulatory, Respiratory, and Digestive Systems in Pupae of the Tobacco Hornworm, Manduca sexta

    OpenAIRE

    2008-01-01

    Circulatory, respiratory, and digestive motions in Manduca sexta pupae were observed using proton-density weighted and fast-imaging with steady-state free procession magnetic resonance microscopy. Proton-density weighted images clearly differentiated pupal air sacs from the hemolymph and organs because, as expected, the air sacs appeared dark in these images. Steady-state free procession imaging allowed real-time monitoring of respiration and circulation, creating movies of hemolymph circulat...

  16. Magnetic Resonance Perfusion Imaging in the Study of Language

    Science.gov (United States)

    Hillis, Argye E.

    2007-01-01

    This paper provides a brief review of various uses of magnetic resonance perfusion imaging in the investigation of brain/language relationships. The reviewed studies illustrate how perfusion imaging can reveal areas of brain where dysfunction due to low blood flow is associated with specific language deficits, and where restoration of blood flow…

  17. Analysis and exploitation of field imperfections in magnetic resonance imaging

    NARCIS (Netherlands)

    Peeters, Johannes Martinus

    2006-01-01

    Field imperfections are normally undesirable in magnetic resonance imaging. They degrade the quality of the images by wrong depiction of the anatomy and decrease of the signal-to-noise ratio. Furthermore, for velocity, flow and diffusion quantification, measurement errors related to these imperfecti

  18. Reducing Field Distortion in Magnetic Resonance Imaging

    Science.gov (United States)

    Eom, Byeong Ho; Penanen, Konstantin; Hahn, Inseob

    2010-01-01

    A concept for a magnetic resonance imaging (MRI) system that would utilize a relatively weak magnetic field provides for several design features that differ significantly from the corresponding features of conventional MRI systems. Notable among these features are a magnetic-field configuration that reduces (relative to the conventional configuration) distortion and blurring of the image, the use of a superconducting quantum interference device (SQUID) magnetometer as the detector, and an imaging procedure suited for the unconventional field configuration and sensor. In a typical application of MRI, a radio-frequency pulse is used to excite precession of the magnetic moments of protons in an applied magnetic field, and the decaying precession is detected for a short time following the pulse. The precession occurs at a resonance frequency proportional to the strengths of the magnetic field and the proton magnetic moment. The magnetic field is configured to vary with position in a known way; hence, by virtue of the aforesaid proportionality, the resonance frequency varies with position in a known way. In other words, position is encoded as resonance frequency. MRI using magnetic fields weaker than those of conventional MRI offers several advantages, including cheaper and smaller equipment, greater compatibility with metallic objects, and higher image quality because of low susceptibility distortion and enhanced spin-lattice-relaxation- time contrast. SQUID MRI is being developed into a practical MRI method for applied magnetic flux densities of the order of only 100 T

  19. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... I-131 Therapy Radiology and You Sponsored by Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography ( ... pictures of the major blood vessels throughout your body. It may be performed with or without contrast ...

  20. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA is a noninvasive test ... of the major blood vessels throughout your body. It may be performed with or without contrast material ...

  1. single voxel magnetic resonance spectroscopy in distinguishing ...

    African Journals Online (AJOL)

    2011-03-03

    Mar 3, 2011 ... magnetic resonance spectroscopy (MRI, MRS) in differentiating focal neoplastic lesions from focal non- ..... this study, it is important to note that there were distinct differences in the .... Applications of MRS in the. 13. evaluation ...

  2. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA is a noninvasive test ... of the major blood vessels throughout your body. It may be performed with or without contrast material ...

  3. Can magnetic resonance imaging differentiate undifferentiated arthritis?

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Duer, Anne; Hørslev-Petersen, K

    2005-01-01

    A high sensitivity for the detection of inflammatory and destructive changes in inflammatory joint diseases makes magnetic resonance imaging potentially useful for assigning specific diagnoses, such as rheumatoid arthritis and psoriatic arthritis in arthritides, that remain undifferentiated after...... conventional clinical, biochemical and radiographic examinations. With recent data as the starting point, the present paper describes the current knowledge on magnetic resonance imaging in the differential diagnosis of undifferentiated arthritis....

  4. Enhancement of artificial magnetism via resonant bianisotropy

    CERN Document Server

    Markovich, Dmitry; Shalin, Alexander; Samusev, Anton; Krasnok, Alexander; Belov, Pavel; Ginzburg, Pavel

    2015-01-01

    All-dielectric "magnetic light" nanophotonics based on high refractive index nanoparticles allows controlling magnetic component of light at nanoscale without having high dissipative losses. The artificial magnetic optical response of such nanoparticles originates from circular displacement currents excited inside those structures and strongly depends on geometry and dispersion of optical materials. Here a new approach for increasing magnetic response via resonant bianisotropy effect is proposed and analyzed. The key mechanism of enhancement is based on electric-magnetic interaction between two electrically and magnetically resonant nanoparticles of all-dielectric dimer nanoantenna. It was shown that proper geometrical arrangement of the dimer in respect to the incident illumination direction allows flexible control over all vectorial components of magnetic polarizability, tailoring the later in the dynamical range of 100 % and enhancement up to 36 % relative to performances of standalone spherical particles....

  5. Torque-mixing Magnetic Resonance Spectroscopy

    Science.gov (United States)

    Losby, Joseph; Fani Sani, Fatemeh; Grandmont, Dylan; Diao, Zhu; Belov, Miro; Burgess, Jacob; Compton, Shawn; Hiebert, Wayne; Vick, Doug; Mohammad, Kaveh; Salimi, Elham; Bridges, Gregory; Thomson, Douglas; Freeman, Mark

    A universal, mechanical torque method for magnetic resonance spectroscopy is presented. In analogy to resonance detection by induction, a signal proportional to the transverse component of a precessing dipole moment can be measured as a pure mechanical torque in broadband, frequency-swept spectroscopy. Comprehensive electron spin resonance of a single-crystal, mesoscopic yttrium iron garnet disk at room temperature are presented to demonstrate the method. The rich detail allows analysis of even complex 3D spin textures.

  6. Magnetic Resonance Imaging (MRI) - Spine

    Science.gov (United States)

    ... their nature and the strength of the MRI magnet. Many implanted devices will have a pamphlet explaining ... large cylinder-shaped tube surrounded by a circular magnet. You will lie on a moveable examination table ...

  7. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... a powerful magnetic field, radio waves and a computer to produce detailed pictures of the inside of ... powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures of organs, soft tissues, ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... a powerful magnetic field, radio waves and a computer to produce detailed pictures of the brain and ... powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures of organs, soft tissues, ...

  9. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... a powerful magnetic field, radio waves and a computer to produce detailed pictures of the inside of ... powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures of organs, soft tissues, ...

  10. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... a powerful magnetic field, radio waves and a computer to produce detailed pictures of the brain and ... powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures of organs, soft tissues, ...

  11. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... help detect certain chronic diseases of the nervous system, such as multiple sclerosis diagnose problems with the ... the magnet. Some MRI units, called short-bore systems , are designed so that the magnet does not ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... of the head uses a powerful magnetic field, radio waves and a computer to produce detailed pictures ... medical conditions. MRI uses a powerful magnetic field, radio frequency pulses and a computer to produce detailed ...

  13. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... help detect certain chronic diseases of the nervous system, such as multiple sclerosis diagnose problems with the ... the magnet. Some MRI units, called short-bore systems , are designed so that the magnet does not ...

  14. Quantifying mixing using magnetic resonance imaging.

    Science.gov (United States)

    Tozzi, Emilio J; McCarthy, Kathryn L; Bacca, Lori A; Hartt, William H; McCarthy, Michael J

    2012-01-25

    Mixing is a unit operation that combines two or more components into a homogeneous mixture. This work involves mixing two viscous liquid streams using an in-line static mixer. The mixer is a split-and-recombine design that employs shear and extensional flow to increase the interfacial contact between the components. A prototype split-and-recombine (SAR) mixer was constructed by aligning a series of thin laser-cut Poly (methyl methacrylate) (PMMA) plates held in place in a PVC pipe. Mixing in this device is illustrated in the photograph in Fig. 1. Red dye was added to a portion of the test fluid and used as the minor component being mixed into the major (undyed) component. At the inlet of the mixer, the injected layer of tracer fluid is split into two layers as it flows through the mixing section. On each subsequent mixing section, the number of horizontal layers is duplicated. Ultimately, the single stream of dye is uniformly dispersed throughout the cross section of the device. Using a non-Newtonian test fluid of 0.2% Carbopol and a doped tracer fluid of similar composition, mixing in the unit is visualized using magnetic resonance imaging (MRI). MRI is a very powerful experimental probe of molecular chemical and physical environment as well as sample structure on the length scales from microns to centimeters. This sensitivity has resulted in broad application of these techniques to characterize physical, chemical and/or biological properties of materials ranging from humans to foods to porous media (1, 2). The equipment and conditions used here are suitable for imaging liquids containing substantial amounts of NMR mobile (1)H such as ordinary water and organic liquids including oils. Traditionally MRI has utilized super conducting magnets which are not suitable for industrial environments and not portable within a laboratory (Fig. 2). Recent advances in magnet technology have permitted the construction of large volume industrially compatible magnets suitable for

  15. Early experience with X-ray magnetic resonance fusion for low-flow vascular malformations in the pediatric interventional radiology suite

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Tiffany J. [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Keck School of Medicine of the University of Southern California, Los Angeles, CA (United States); Girard, Erin [Siemens Corporation, Corporate Technology, Princeton, NJ (United States); Shellikeri, Sphoorti; Vossough, Arastoo; Ho-Fung, Victor; Cahill, Anne Marie [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Setser, Randolph [Siemens Medical Solutions USA, Inc., Hoffman Estates, IL (United States)

    2016-03-15

    This technical innovation describes our experience using an X-ray magnetic resonance fusion (XMRF) software program to overlay 3-D MR images on real-time fluoroscopic images during sclerotherapy procedures for vascular malformations at a large pediatric institution. Five cases have been selected to illustrate the application and various clinical utilities of XMRF during sclerotherapy procedures as well as the technical limitations of this technique. The cases demonstrate how to use XMRF in the interventional suite to derive additional information to improve therapeutic confidence with regards to the extent of lesion filling and to guide clinical management in terms of intraprocedural interventional measures. (orig.)

  16. Magnetic-resonance velocity mapping of the central circulation

    DEFF Research Database (Denmark)

    Søndergaard, Lise

    1994-01-01

    In magnetic-resonance (MR) velocity mapping there exists a linear relationship between the velocity and signal in each element of a tomographic image. The technique can be used for quantitative measurements of linear velocities (m s-1) and flow rates (1 min-1). By using cinematographic images...... the flow profile during the cardiac cycle can be determined. This allows quantification of forward flow, regurgitant volume and regurgitant fraction in cases of heart-valve insufficiency. In valvular stenosis the transvalvular pressure gradient and valve area can be determined. Magnetic-resonance velocity...... mapping may also provide information about diastolic function of left ventricular function. Together with other MR imaging techniques, velocity mapping gives an accurate assessment of the severity of aortic dissection. Recent studies indicate that MR velocity mapping provides quantification of renal blood...

  17. Magnetic nanoparticles in magnetic resonance imaging and diagnostics.

    Science.gov (United States)

    Rümenapp, Christine; Gleich, Bernhard; Haase, Axel

    2012-05-01

    Magnetic nanoparticles are useful as contrast agents for magnetic resonance imaging (MRI). Paramagnetic contrast agents have been used for a long time, but more recently superparamagnetic iron oxide nanoparticles (SPIOs) have been discovered to influence MRI contrast as well. In contrast to paramagnetic contrast agents, SPIOs can be functionalized and size-tailored in order to adapt to various kinds of soft tissues. Although both types of contrast agents have a inducible magnetization, their mechanisms of influence on spin-spin and spin-lattice relaxation of protons are different. A special emphasis on the basic magnetism of nanoparticles and their structures as well as on the principle of nuclear magnetic resonance is made. Examples of different contrast-enhanced magnetic resonance images are given. The potential use of magnetic nanoparticles as diagnostic tracers is explored. Additionally, SPIOs can be used in diagnostic magnetic resonance, since the spin relaxation time of water protons differs, whether magnetic nanoparticles are bound to a target or not.

  18. Society for Cardiovascular Magnetic Resonance guidelines for reporting cardiovascular magnetic resonance examinations

    Directory of Open Access Journals (Sweden)

    van Rossum Albert C

    2009-03-01

    Full Text Available Abstract These reporting guidelines are recommended by the Society for Cardiovascular Magnetic Resonance (SCMR to provide a framework for healthcare delivery systems to disseminate cardiac and vascular imaging findings related to the performance of cardiovascular magnetic resonance (CMR examinations.

  19. Magnetic heat pump flow director

    Science.gov (United States)

    Howard, Frank S. (Inventor)

    1995-01-01

    A fluid flow director is disclosed. The director comprises a handle body and combed-teeth extending from one side of the body. The body can be formed of a clear plastic such as acrylic. The director can be used with heat exchangers such as a magnetic heat pump and can minimize the undesired mixing of fluid flows. The types of heat exchangers can encompass both heat pumps and refrigerators. The director can adjust the fluid flow of liquid or gas along desired flow directions. A method of applying the flow director within a magnetic heat pump application is also disclosed where the comb-teeth portions of the director are inserted into the fluid flow paths of the heat pump.

  20. Magnetic resonance imaging of iliotibial band syndrome.

    Science.gov (United States)

    Ekman, E F; Pope, T; Martin, D F; Curl, W W

    1994-01-01

    Seven cases of iliotibial band syndrome and the pathoanatomic findings of each, as demonstrated by magnetic resonance imaging, are presented. These findings were compared with magnetic resonance imaging scans of 10 age- and sex-matched control knees without evidence of lateral knee pain. Magnetic resonance imaging signal consistent with fluid was seen deep to the iliotibial band in the region of the lateral femoral epicondyle in five of the seven cases. Additionally, when compared with the control group, patients with iliotibial band syndrome demonstrated a significantly thicker iliotibial band over the lateral femoral epicondyle (P iliotibial band in the disease group was 5.49 +/- 2.12 mm, as opposed to 2.52 +/- 1.56 mm in the control group. Cadaveric dissections were performed on 10 normal knees to further elucidate the exact nature of the area under the iliotibial band. A potential space, i.e., a bursa, was found between the iliotibial band and the knee capsule. This series suggests that magnetic resonance imaging demonstrates objective evidence of iliotibial band syndrome and can be helpful when a definitive diagnosis is essential. Furthermore, correlated with anatomic dissection, magnetic resonance imaging identifies this as a problem within a bursa beneath the iliotibial band and not a problem within the knee joint.

  1. Embroidered Coils for Magnetic Resonance Sensors

    Directory of Open Access Journals (Sweden)

    Michael I. Newton

    2013-04-01

    Full Text Available Magnetic resonance imaging is a widely used technique for medical and materials imaging. Even though the objects being imaged are often irregularly shaped, suitable coils permitting the measurement of the radio-frequency signal in these systems are usually made of solid copper. One problem often encountered is how to ensure the coils are both in close proximity and conformal to the object being imaged. Whilst embroidered conductive threads have previously been used as antennae in mobile telecommunications applications, they have not previously been reported for use within magnetic resonance. In this paper we show that an embroidered single loop coil can be used in a commercial unilateral nuclear magnetic resonance system as an alternative to a solid copper. Data is presented showing the determination of both longitudinal (T1 and effective transverse (T2eff relaxation times for a flat fabric coil and the same coil conformed to an 8 cm diameter cylinder. We thereby demonstrate the principles required for the wider use of fabric based conformal coils within nuclear magnetic resonance and magnetic resonance imaging.

  2. Magnetic resonance of magnetic fluid and magnetoliposome preparations

    Energy Technology Data Exchange (ETDEWEB)

    Morais, Paulo C. [Universidade de Brasilia, Instituto de Fisica, Nucleo de Fisica Aplicada, 70919-970 Brasilia-DF (Brazil)]. E-mail: pcmor@unb.br; Santos, Judes G. [Universidade de Brasilia, Instituto de Fisica, Nucleo de Fisica Aplicada, 70919-970 Brasilia-DF (Brazil); Skeff Neto, K. [Universidade de Brasilia, Instituto de Fisica, Nucleo de Fisica Aplicada, 70919-970 Brasilia-DF (Brazil); Pelegrini, Fernando [Universidade Federal de Goias, Instituto de Fisica, 74001-970 Goiania-GO (Brazil); Cuyper, Marcel de [Katholieke Universiteit Leuven, Campus Kortrijk, Interdisciplinary Research Centre, B-8500 Kortrijk (Belgium)

    2005-05-15

    In this study, magnetic resonance was used to investigate lauric acid-coated magnetite-based magnetic fluid particles and particles which are surrounded by a double layer of phospholipid molecules (magnetoliposomes). The data reveal the presence of monomers and dimers in both samples. Whereas evidence for a thermally induced disruption of dimers is found in the magnetic fluid, apparently, the bilayer phospholipid envelop prevents the dissociation in the magnetoliposome samples.

  3. Tutte polynomial in functional magnetic resonance imaging

    Science.gov (United States)

    García-Castillón, Marlly V.

    2015-09-01

    Methods of graph theory are applied to the processing of functional magnetic resonance images. Specifically the Tutte polynomial is used to analyze such kind of images. Functional Magnetic Resonance Imaging provide us connectivity networks in the brain which are represented by graphs and the Tutte polynomial will be applied. The problem of computing the Tutte polynomial for a given graph is #P-hard even for planar graphs. For a practical application the maple packages "GraphTheory" and "SpecialGraphs" will be used. We will consider certain diagram which is depicting functional connectivity, specifically between frontal and posterior areas, in autism during an inferential text comprehension task. The Tutte polynomial for the resulting neural networks will be computed and some numerical invariants for such network will be obtained. Our results show that the Tutte polynomial is a powerful tool to analyze and characterize the networks obtained from functional magnetic resonance imaging.

  4. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... if your child has any implanted medical or electronic devices. Inform your doctor and the technologist prior ... magnetic field of the MRI unit, metal and electronic items are not allowed in the exam room. ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... magnetic field of the MRI unit, metal and electronic items are not allowed in the exam room. ... tell the technologist if you have medical or electronic devices in your body. These objects may interfere ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... conditions. MRI uses a powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures ... with claustrophobia. Newer open MRI units provide very high quality images for many types of exams. Older ...

  7. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... conditions. MRI uses a powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures ... with claustrophobia. Newer open MRI units provide very high quality images for many types of exams; however, ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or headphones ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media MR Angiography ( ...

  9. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... and extremities. Tell your doctor about your child’s health problems, medications, recent surgeries and allergies. The magnetic ... the radiologist if your child has any serious health problems or has recently had surgery. Some conditions, ...

  10. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... imaging (MRI) uses a powerful magnetic field, radio waves and a computer to produce detailed pictures of ... the body being imaged, send and receive radio waves, producing signals that are detected by the coils. ...

  11. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the head uses a powerful magnetic field, radio waves and a computer to produce detailed pictures of ... the body being imaged, send and receive radio waves, producing signals that are detected by the coils. ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... food, or the environment, or if you have asthma. The contrast material most commonly used for an ... also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or headphones ...

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... pregnant. The magnetic field is not harmful, but it may cause some medical devices to malfunction. Most ... number of abrupt onset or long-standing symptoms. It can help diagnose conditions such as: brain tumors ...

  14. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... allergies. The magnetic field is not harmful, but it may cause some medical devices to malfunction. Most ... cord is needed, MRI is useful because of its ability to see through the skull and the ...

  15. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... magnetic field is produced by passing an electric current through wire coils in most MRI units. Other ... that are detected by the coils. The electric current does not come in contact with the patient. ...

  16. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... magnetic field is produced by passing an electric current through wire coils in most MRI units. Other ... that are detected by the coils. The electric current does not come in contact with the patient. ...

  17. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... or potentially pose a risk, depending on their nature and the strength of the MRI magnet. Many ... of the body being studied. If a contrast material will be used in the MRI exam, a ...

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... or potentially pose a risk, depending on their nature and the strength of the MRI magnet. Many ... is positioned around the head. If a contrast material will be used in the MRI exam, a ...

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... intercom. Many MRI centers allow a friend or parent to stay in the room as long as they are also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or headphones ...

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... allergies and whether there’s a possibility you are pregnant. The magnetic field is not harmful, but it ... if there is any possibility that they are pregnant. MRI has been used for scanning patients since ...

  1. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... scanner. top of page How does the procedure work? Unlike conventional x-ray examinations and computed tomography ( ... as long as they are also screened for safety in the magnetic environment. Children will be given ...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... scanner. top of page How does the procedure work? Unlike conventional x-ray examinations and computed tomography ( ... as long as they are also screened for safety in the magnetic environment. Children will be given ...

  3. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... your child’s health problems, medications, recent surgeries and allergies. The magnetic field is not harmful, but it ... the exam if your child has a known allergy to contrast material. Your child should wear loose, ...

  4. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... if your child has any implanted medical or electronic devices. Inform your doctor and the technologist prior ... magnetic field of the MRI unit, metal and electronic items are not allowed in the exam room. ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... magnetic field of the MRI unit, metal and electronic items are not allowed in the exam room. ... tell the technologist if you have medical or electronic devices in your body. These objects may interfere ...

  6. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Tell your doctor about your child’s health problems, medications, recent surgeries and allergies. The magnetic field is ... routine and have him/her take food and medications as usual. Some MRI examinations may require your ...

  7. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... doctor about your child’s health problems, medications, recent surgeries and allergies. The magnetic field is not harmful, ... to the heart muscle evaluate findings following cardiovascular surgery In the abdominal and pelvic region, MRI is ...

  8. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... allergies. The magnetic field is not harmful, but it may cause some medical devices to malfunction. Most ... cord is needed, MRI is useful because of its ability to see through the skull and the ...

  9. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... pregnant. The magnetic field is not harmful, but it may cause some medical devices to malfunction. Most ... number of abrupt onset or long-standing symptoms. It can help diagnose conditions such as: brain tumors ...

  10. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... x-ray contrast material, drugs, food, or the environment, or if you have asthma. The contrast material ... are also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or ...

  11. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... x-ray contrast material, drugs, food, or the environment, or if your child has asthma. The contrast ... are also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... be examined on a computer monitor, transmitted electronically, printed or copied to a CD or uploaded to ... magnetic field of the MRI unit, metal and electronic items are not allowed in the exam room. ...

  13. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... be examined on a computer monitor, transmitted electronically, printed or copied to a CD or uploaded to ... magnetic field of the MRI unit, metal and electronic items are not allowed in the exam room. ...

  14. Magnetic resonance signal moment determination using the Earth's magnetic field

    Science.gov (United States)

    Fridjonsson, E. O.; Creber, S. A.; Vrouwenvelder, J. S.; Johns, M. L.

    2015-03-01

    We demonstrate a method to manipulate magnetic resonance data such that the moments of the signal spatial distribution are readily accessible. Usually, magnetic resonance imaging relies on data acquired in so-called k-space which is subsequently Fourier transformed to render an image. Here, via analysis of the complex signal in the vicinity of the centre of k-space we are able to access the first three moments of the signal spatial distribution, ultimately in multiple directions. This is demonstrated for biofouling of a reverse osmosis (RO) membrane module, rendering unique information and an early warning of the onset of fouling. The analysis is particularly applicable for the use of mobile magnetic resonance spectrometers; here we demonstrate it using an Earth's magnetic field system.

  15. Magnetic resonance signal moment determination using the Earth's magnetic field

    KAUST Repository

    Fridjonsson, Einar Orn

    2015-03-01

    We demonstrate a method to manipulate magnetic resonance data such that the moments of the signal spatial distribution are readily accessible. Usually, magnetic resonance imaging relies on data acquired in so-called k-space which is subsequently Fourier transformed to render an image. Here, via analysis of the complex signal in the vicinity of the centre of k-space we are able to access the first three moments of the signal spatial distribution, ultimately in multiple directions. This is demonstrated for biofouling of a reverse osmosis (RO) membrane module, rendering unique information and an early warning of the onset of fouling. The analysis is particularly applicable for the use of mobile magnetic resonance spectrometers; here we demonstrate it using an Earth\\'s magnetic field system.

  16. Magnetic resonance imaging of valvular heart disease

    DEFF Research Database (Denmark)

    Søndergaard, Lise; Ståhlberg, F; Thomsen, C

    1999-01-01

    The optimum management of patients with valvular heart diseases requires accurate and reproducible assessment of the valvular lesion and its hemodynamic consequences. Magnetic resonance imaging (MRI) techniques, such as volume measurements, signal-void phenomena, and velocity mapping, can be used...... the optimal timing for valvular surgery. This paper reviews the validation of these MRI techniques in assessing valvular heart disease and discusses some typical pitfalls of the techniques, including suggestions for solutions.J. Magn. Reson. Imaging 1999;10:627-638....

  17. Magnetic Microparticle Aggregation For Viscosity Determination By Magnetic Resonance

    Science.gov (United States)

    Hong, Rui; Cima, Michael J.; Weissleder, Ralph; Josephson, Lee

    2009-01-01

    Micron-sized magnetic particles were induced to aggregate when placed in homogeneous magnetic fields, like those of magnetic resonance (MR) imagers and relaxometers, and then spontaneously returned to their dispersed state when removed from the field. Associated with the aggregation and dispersion of the magnetic particles were time dependent increases and decreases in the spin-spin relaxation time (T2) of the water. Magnetic nanoparticles, with far smaller magnetic moments per particle, did not undergo magnetically induced aggregation, and exhibited time independent values of T2. The rate of T2 change associated with magnetic micro-particle aggregation was used to determine the viscosity of liquid samples, providing a method that can be of particular advantage for determining the viscosity of small volumes of potentially biohazardous samples of blood or blood plasma. PMID:18306403

  18. Clinical application of functional magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Alwatban, Adnan Z.W

    2002-07-01

    The work described in this thesis was carried out at the Magnetic Resonance Centre of the University of Nottingham during the time from May 1998 to April 2001, and is the work of the author except where indicated by reference. The main source of signal changes in functional magnetic resonance imaging (fMRJ) is the fluctuation of paramagnetic deoxyhaemoglobin in the venous blood during different states of functional performance. For the work of this thesis, fMRI studies were carried out using a 3 T MR system with an echo planar imaging (EPI) pulse sequence. Hearing research utilising fMRI has been previously reported in normal subjects. Hearing fMRI is normally performed by stimulating the auditory cortex via an acoustic task presentation such as music, tone, etc. However, performing the same research on deaf subjects requires special equipment to be designed to allow direct stimulation of the auditory nerve. In this thesis, a new method of direct electrical stimulation of the auditory nerve is described that uses a transtympanic electrode implanted onto the surface of the cochlea. This approach would however, result in electromotive forces (EMFs) being induced by the time varying magnetic field, which would lead to current flow and heating, as well as deflection of the metallic electrode within the static magnetic field, and image distortion due to the magnetic susceptibility difference. A gold-plated tungsten electrode with a zero magnetic susceptibility was developed to avoid image distortion. Used with carbon leads and a carbon reference pad, it enabled safe, distortion-free fMRI studies of deaf subjects. The study revealed activation of the primary auditory cortex. This fMRI procedure can be used to demonstrate whether the auditory pathway is fully intact, and may provide a useful method for pre-operative assessment of candidates for cochlear implantation. Glucose is the energy source on which the function of the human brain is entirely dependent. Failure to

  19. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... evaluate infections assess blood flow to the heart muscle evaluate findings following cardiovascular surgery In the abdominal ... IV line, into a vein in your child’s hand or arm. A saline solution may be used ...

  20. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... flow to the heart muscle evaluate findings following cardiovascular surgery In the abdominal and pelvic region, MRI ... of heart disease, asthma, diabetes, kidney disease or thyroid problems. Any of these conditions may influence the ...

  1. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... assess causes of arrhythmia (abnormal heart rhythm) evaluate infections assess blood flow to the heart muscle evaluate ... the presence of an otherwise hidden tumor or infection in a joint diagnose developmental joint abnormalities in ...

  2. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... evaluate infections assess blood flow to the heart muscle evaluate findings following cardiovascular surgery In the abdominal ... or infection in a joint diagnose developmental joint abnormalities in children detect bone cancer inspect the marrow ...

  3. Near-zero-field nuclear magnetic resonance

    OpenAIRE

    Ledbetter, Micah; Theis, Thomas; Blanchard, John; Ring, Hattie; Ganssle, Paul; Appelt, Stephan; Bluemich, Bernhard; Pines, Alex; Budker, Dmitry

    2011-01-01

    We investigate nuclear magnetic resonance (NMR) in near-zero-field, where the Zeeman interaction can be treated as a perturbation to the electron mediated scalar interaction (J-coupling). This is in stark contrast to the high field case, where heteronuclear J-couplings are normally treated as a small perturbation. We show that the presence of very small magnetic fields results in splitting of the zero-field NMR lines, imparting considerable additional information to the pure zero-field spectr...

  4. Magnetic resonance perfusion imaging without contrast media

    Energy Technology Data Exchange (ETDEWEB)

    Martirosian, Petros; Graf, Hansjoerg; Schick, Fritz [University Hospital of Tuebingen, Section on Experimental Radiology, Tuebingen (Germany); Boss, Andreas; Schraml, Christina; Schwenzer, Nina F.; Claussen, Claus D. [University Hospital of Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2010-08-15

    Principles of magnetic resonance imaging techniques providing perfusion-related contrast weighting without administration of contrast media are reported and analysed systematically. Especially common approaches to arterial spin labelling (ASL) perfusion imaging allowing quantitative assessment of specific perfusion rates are described in detail. The potential of ASL for perfusion imaging was tested in several types of tissue. After a systematic comparison of technical aspects of continuous and pulsed ASL techniques the standard kinetic model and tissue properties of influence to quantitative measurements of perfusion are reported. For the applications demonstrated in this paper a flow-sensitive alternating inversion recovery (FAIR) ASL perfusion preparation approach followed by true fast imaging with steady precession (true FISP) data recording was developed and implemented on whole-body scanners operating at 0.2, 1.5 and 3 T for quantitative perfusion measurement in various types of tissue. ASL imaging provides a non-invasive tool for assessment of tissue perfusion rates in vivo. Images recorded from kidney, lung, brain, salivary gland and thyroid gland provide a spatial resolution of a few millimetres and sufficient signal to noise ratio in perfusion maps after 2-5 min of examination time. Newly developed ASL techniques provide especially high image quality and quantitative perfusion maps in tissues with relatively high perfusion rates (as also present in many tumours). Averaging of acquisitions and image subtraction procedures are mandatory, leading to the necessity of synchronization of data recording to breathing in abdominal and thoracic organs. (orig.)

  5. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Therapy November 8 is the International Day of Radiology (IDoR) Radiology and You Sponsored by Image/Video Gallery Your ... Explains Magnetic Resonance Angiography (MRA) Transcript Welcome to Radiology Info dot org Hello, I’m Dr. Elliot ...

  6. Functional Magnetic Resonance Imaging in Consumer Research

    DEFF Research Database (Denmark)

    Reimann, Martin; Schilke, Oliver; Weber, Bernd

    2011-01-01

    Although the field of psychology is undergoing an immense shift toward the use of functional magnetic resonance imaging (fMRI), the application of this methodology to consumer research is relatively new. To assist consumer researchers in understanding fMRI, this paper elaborates on the findings...

  7. Modelling Strategies for Functional Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Madsen, Kristoffer Hougaard

    2009-01-01

    This thesis collects research done on several models for the analysis of functional magnetic resonance neuroimaging (fMRI) data. Several extensions for unsupervised factor analysis type decompositions including explicit delay modelling as well as handling of spatial and temporal smoothness...

  8. Automated Segmentation of Cardiac Magnetic Resonance Images

    DEFF Research Database (Denmark)

    Stegmann, Mikkel Bille; Nilsson, Jens Chr.; Grønning, Bjørn A.

    2001-01-01

    Magnetic resonance imaging (MRI) has been shown to be an accurate and precise technique to assess cardiac volumes and function in a non-invasive manner and is generally considered to be the current gold-standard for cardiac imaging [1]. Measurement of ventricular volumes, muscle mass and function...

  9. Interactive Real-time Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Brix, Lau

    Real-time acquisition, reconstruction and interactively changing the slice position using magnetic resonance imaging (MRI) have been possible for years. However, the current clinical use of interactive real-time MRI is limited due to an inherent low spatial and temporal resolution. This PhD proje...

  10. Pituitary magnetic resonance imaging in Cushing's disease.

    Science.gov (United States)

    Vitale, Giovanni; Tortora, Fabio; Baldelli, Roberto; Cocchiara, Francesco; Paragliola, Rosa Maria; Sbardella, Emilia; Simeoli, Chiara; Caranci, Ferdinando; Pivonello, Rosario; Colao, Annamaria

    2017-03-01

    Adrenocorticotropin-secreting pituitary tumor represents about 10 % of pituitary adenomas and at the time of diagnosis most of them are microadenomas. Transsphenoidal surgery is the first-line treatment of Cushing's disease and accurate localization of the tumor within the gland is essential for selectively removing the lesion and preserving normal pituitary function. Magnetic resonance imaging is the best imaging modality for the detection of pituitary tumors, but adrenocorticotropin-secreting pituitary microadenomas are not correctly identified in 30-50 % of cases, because of their size, location, and enhancing characteristics. Several recent studies were performed with the purpose of better localizing the adrenocorticotropin-secreting microadenomas through the use in magnetic resonance imaging of specific sequences, reduced contrast medium dose and high-field technology. Therefore, an improved imaging technique for pituitary disease is mandatory in the suspect of Cushing's disease. The aims of this paper are to present an overview of pituitary magnetic resonance imaging in the diagnosis of Cushing's disease and to provide a magnetic resonance imaging protocol to be followed in case of suspicion adrenocorticotropin-secreting pituitary adenoma.

  11. Magnetic resonance imaging in acute tendon ruptures

    Energy Technology Data Exchange (ETDEWEB)

    Daffner, R.H.; Lupetin, A.R.; Dash, N.; Riemer, B.L.

    1986-11-01

    The diagnosis of acute tendon ruptures of the extensor mechanism of the knee or the Achilles tendon of the ankle may usually be made by clinical means. Massive soft tissue swelling accompanying these injuries often obscures the findings, however. Magnetic resonance imaging (MRI) can rapidly demonstrate these tendon ruptures. Examples of the use of MRI for quadriceps tendon, and Achilles tendon rupture are presented.

  12. Breast magnetic resonance imaging guided biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Bo La; Kim, Sun Mi; Jang, Mi Jung [Dept. of Radiology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Cho, Nariya; Moon, Woo Kyung [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of); Kim, Hak Hee [Dept. of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2016-06-15

    Despite the high sensitivity of breast magnetic resonance imaging (MRI), pathologic confirmation by biopsy is essential because of limited specificity. MRI-guided biopsy is required in patients with lesions only seen on MRI. We review preprocedural considerations and the technique of MRI-guided biopsy, challenging situations and trouble-shooting, and correlation of radiologic and pathologic findings.

  13. Was magnetic resonance imaging scan contraindicated?

    Science.gov (United States)

    Rafiq, Muhammad Khizar

    2010-01-01

    An intravenous drug abuser with a retained needle posed a management problem at a neurosurgical unit, having declined magnetic resonance imaging (MRI) on safety grounds. However, later, having been assessed by the senior radiologist, she went though the MRI scan safely.

  14. Brain Morphometry Using Anatomical Magnetic Resonance Imaging

    Science.gov (United States)

    Bansal, Ravi; Gerber, Andrew J.; Peterson, Bradley S.

    2008-01-01

    The efficacy of anatomical magnetic resonance imaging (MRI) in studying the morphological features of various regions of the brain is described, also providing the steps used in the processing and studying of the images. The ability to correlate these features with several clinical and psychological measures can help in using anatomical MRI to…

  15. Biliary ascariasis on magnetic resonance cholangiopancreatography

    Directory of Open Access Journals (Sweden)

    Mohammad A Hashmi

    2009-01-01

    Full Text Available A 17-year-old girl presented with features of biliary obstruction. Magnetic resonance cholangi-pancreatography revealed typical linear signals in common bile duct, which appears like Ascaris lumbricoides. The diagnosis was confirmed by endoscopic removal of the worm.

  16. Sports health magnetic resonance imaging challenge.

    Science.gov (United States)

    Howell, Gary A; Stadnick, Michael E; Awh, Mark H

    2010-11-01

    Injuries to the Lisfranc ligament complex are often suspected, particularly in the setting of midfoot pain without radiographic abnormality. Knowledge of the anatomy and magnetic resonance imaging findings of injuries to this region is helpful for the diagnosing and treating physicians.

  17. Magnetic Resonance Imaging in Biomedical Engineering

    Science.gov (United States)

    Kaśpar, Jan; Hána, Karel; Smrčka, Pavel; Brada, Jiří; Beneš, Jiří; Šunka, Pavel

    2007-11-01

    The basic principles of magnetic resonance imaging covering physical principles and basic imaging techniques will be presented as a strong tool in biomedical engineering. Several applications of MRI in biomedical research practiced at the MRI laboratory of the FBMI CTU including other laboratory instruments and activities are introduced.

  18. Magnetic resonance imaging in radiotherapy treatment planning

    NARCIS (Netherlands)

    Moerland, Marinus Adriaan

    2001-01-01

    From its inception in the early 1970's up to the present, magnetic resonance imaging (MRI) has evolved into a sophisticated technique, which has aroused considerable interest in var- ious subelds of medicine including radiotherapy. MRI is capable of imaging in any plane and does not use ionizing rad

  19. Magnetic Resonance Angiography: Principles and Applications.

    Science.gov (United States)

    Dyke, Lara M

    2013-12-01

    Magnetic Resonance Angiography: Principles and Applications. Carr J. C., Carroll T. J., Springer-Verlag, Heidelberg/New York, 2012. 412 pp. Price $179.00. ISBN 978-1-4419-1685-3 (hardcover). © 2013 American Association of Physicists in Medicine.

  20. Magnetic resonance imaging (MRI) in syringomyelia

    NARCIS (Netherlands)

    H.L.J. Tanghe (Hervé)

    1995-01-01

    textabstractBased on an own material of 19 patients with syringomyelia and on the related literature a survey is given on the diagnosis, differential diagnosis, postoperative evaluation and the dynamics of CSF and cyst fluids, using magnetic resonance imaging (MRI). The following conclusions can be

  1. Evaluation of nuclear magnetic resonance spectroscopy variability

    Energy Technology Data Exchange (ETDEWEB)

    Barreto, Felipe Rodrigues; Salmon, Carlos Ernesto Garrido, E-mail: garrido@ffclrp.usp.br [Universidade de Sao Paulo (FFCLRP/USP), Ribeirao Preto, SP (Brazil). Fac. de Filisofia, Ciencias e Letras; Otaduy, Maria Concepcion Garcia [Universidade de Sao Paulo (FAMUS/USP), Sao Paulo, SP (Brazil). Fac. de Medicina. Departamento de Radiologia

    2014-11-01

    Introduction: the intrinsically high sensitivity of Magnetic Resonance Spectroscopy (MRS) causes considerable variability in metabolite quantification. In this study, we evaluated the variability of MRS in two research centers using the same model of magnetic resonance image scanner. Methods: two metabolic phantoms were created to simulate magnetic resonance spectra from in vivo hippocampus. The phantoms were filled with the same basic solution containing the following metabolites: N-acetyl-aspartate, creatine, choline, glutamate, glutamine and inositol. Spectra were acquired over 15 months on 26 acquisition dates, resulting in a total of 130 spectra per center. Results: the phantoms did not undergo any physical changes during the 15-month period. Temporal analysis from both centers showed mean metabolic variations of 3.7% in acquisitions on the same day and of 8.7% over the 15-month period. Conclusion: The low deviations demonstrated here, combined with the high specificity of Magnetic Resonance Spectroscopy, confirm that it is feasible to use this technique in multicenter studies in neuroscience research. (author)

  2. Interactive Real-time Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Brix, Lau

    Real-time acquisition, reconstruction and interactively changing the slice position using magnetic resonance imaging (MRI) have been possible for years. However, the current clinical use of interactive real-time MRI is limited due to an inherent low spatial and temporal resolution. This PhD proje...

  3. Numerical methods in electron magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Soernes, A.R

    1998-07-01

    The focal point of the thesis is the development and use of numerical methods in the analysis, simulation and interpretation of Electron Magnetic Resonance experiments on free radicals in solids to uncover the structure, the dynamics and the environment of the system.

  4. Magnetic resonance of the spine

    Energy Technology Data Exchange (ETDEWEB)

    Enzmann, D.R.; De La Paz, R.L.; Rubin, J.R.

    1990-01-01

    This book contains 12 chapters. Three chapters discuss principles of cerebrospinal fluid flow, spinal imaging techniques, and the physical basis and anatomic correlates of signal intensity in the spine. There are chapters on normal anatomy, congenital anomalies, trauma, tumors, infection, demyelinating disease, degenerative disease, vascular conditions, and syringomyelia.

  5. Liquid chromatography "on-flow" 1H nuclear magnetic resonance on native glycosphingolipid mixtures together with gas chromatography/mass spectrometry on the released oligosaccharides for screening and characterisation of carbohydrate-based antigens from pig lungs.

    Science.gov (United States)

    Bäcker, A E; Thorbert, S; Rakotonirainy, O; Hallberg, E C; Olling, A; Gustavsson, M; Samuelsson, B E; Soussi, B

    1999-01-01

    Glycosphingolipids were prepared from pig lung and pooled into two fractions with (i) or = 3 sugar residues. Oligosaccharides were prepared and used for gas chromatography, gas chromatography/mass spectrometry and matrix-assisted laser desorption/ionization mass spectrometry. The glycolipid fractions i and ii were further characterised and purified using a novel method based on high performance liquid chromatography "on-flow" proton nuclear magnetic resonance. The LC "on-flow" NMR technique showed good chromatographic separation and gave NMR spectral information which could be used as guidance for pooling of the separated mixture glycolipids. Conventional 1H NMR, thin layer immunostaining, gas chromatography, gas chromatography/mass spectrometry and matrix-assisted laser desorption/ionization mass spectrometry were used to characterise the glycolipids and to validate LC-NMR spectral data.

  6. Interaction of magnetic resonators studied by the magnetic field enhancement

    Science.gov (United States)

    Hou, Yumin

    2013-12-01

    It is the first time that the magnetic field enhancement (MFE) is used to study the interaction of magnetic resonators (MRs), which is more sensitive than previous parameters-shift and damping of resonance frequency. To avoid the coherence of lattice and the effect of Bloch wave, the interaction is simulated between two MRs with same primary phase when the distance is changed in the range of several resonance wavelengths, which is also compared with periodic structure. The calculated MFE oscillating and decaying with distance with the period equal to resonance wavelength directly shows the retardation effect. Simulation also shows that the interaction at normal incidence is sensitive to the phase correlation which is related with retardation effect and is ultra-long-distance interaction when the two MRs are strongly localized. When the distance is very short, the amplitude of magnetic resonance is oppressed by the strong interaction and thus the MFE can be much lower than that of single MR. This study provides the design rules of metamaterials for engineering resonant properties of MRs.

  7. Interaction of magnetic resonators studied by the magnetic field enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Hou, Yumin, E-mail: ymhou@pku.edu.cn [State Key Laboratory for Mesoscopic Physics, School of Physics, Peking University, Beijing 100871 (China)

    2013-12-15

    It is the first time that the magnetic field enhancement (MFE) is used to study the interaction of magnetic resonators (MRs), which is more sensitive than previous parameters–shift and damping of resonance frequency. To avoid the coherence of lattice and the effect of Bloch wave, the interaction is simulated between two MRs with same primary phase when the distance is changed in the range of several resonance wavelengths, which is also compared with periodic structure. The calculated MFE oscillating and decaying with distance with the period equal to resonance wavelength directly shows the retardation effect. Simulation also shows that the interaction at normal incidence is sensitive to the phase correlation which is related with retardation effect and is ultra-long-distance interaction when the two MRs are strongly localized. When the distance is very short, the amplitude of magnetic resonance is oppressed by the strong interaction and thus the MFE can be much lower than that of single MR. This study provides the design rules of metamaterials for engineering resonant properties of MRs.

  8. Interaction of magnetic resonators studied by the magnetic field enhancement

    Directory of Open Access Journals (Sweden)

    Yumin Hou

    2013-12-01

    Full Text Available It is the first time that the magnetic field enhancement (MFE is used to study the interaction of magnetic resonators (MRs, which is more sensitive than previous parameters–shift and damping of resonance frequency. To avoid the coherence of lattice and the effect of Bloch wave, the interaction is simulated between two MRs with same primary phase when the distance is changed in the range of several resonance wavelengths, which is also compared with periodic structure. The calculated MFE oscillating and decaying with distance with the period equal to resonance wavelength directly shows the retardation effect. Simulation also shows that the interaction at normal incidence is sensitive to the phase correlation which is related with retardation effect and is ultra-long-distance interaction when the two MRs are strongly localized. When the distance is very short, the amplitude of magnetic resonance is oppressed by the strong interaction and thus the MFE can be much lower than that of single MR. This study provides the design rules of metamaterials for engineering resonant properties of MRs.

  9. Magnetic resonance imaging of infectious myositis

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Ji Young; Kim, Jee Young; Kim, Sang Heum; Jung, Youn Ju; Cha, Eun Suk; Park, Joung Mi; Park, Young Ha [The Catholic Univ., College of Medicine, Suwon (Korea, Republic of)

    1998-09-01

    To describe the findings of magnetic resonance imaging in infectious myositis and to determine their value for differentiation between ruberculous and bacterial myositis. Magnetic resonance images of ten proven cases of infectious myositis (five tuberculous and five bacterial) were retrospectively reviewed in the light of clinical and laboratory findings. On the basis of magnetic resonance images, signal intensity of the mass, the presence or absence of an abscess, signal intensity of the peripheral wall, patterns of contrast enhancement, and associated findings were evaluated. Compared with those of bacterial myositis, the symptoms of tuberculous myositis lasted longer but there were no difinite local inflammatory signs. In three of five cases of bacterial myositis there were specific medical records;trauma in two cases and systemic lupus erythematosus in one. All tuberculous myositis cases involved a single muscle, but bacterial myositis affected multipe muscles in three cases(60%). All but one case showed a mass in the involved muscles. In one bacterial case, there was diffuse swelling in the involved muscle. On T1-weighted images, eight infectious cases showed low signal intensity;two, of the bactrerial type, showed subtle increased signal intensity. all cases demonstrated high signal intensity on t2-weighted images. The signal intensity of peripheral wall was slightly increased on T1-weighted images, but low on T2-weighted. In four cases there was associated cellulitis, and in one case each, adjacent joint effusion and deep vein thrombosis were seen. After gadolinium infusion, peripheral rim enhancement was noted in nine cases and heterogeneous enhancement in one. After magnetic resonance imaging of infectious myositis, the characteristic finding was an abscessed lesion, with the peripheral wall showing high signal intensity on T1-weighted images and low signal intensity on T2 weighted. Although we found it difficult to differentiate bacterial from tuberculous

  10. Positron emission tomography/magnetic resonance hybrid scanner imaging of cerebral blood flow using 15O-water positron emission tomography and arterial spin labeling magnetic resonance imaging in newborn piglets

    DEFF Research Database (Denmark)

    Andersen, Julie B; Henning, William S; Lindberg, Ulrich;

    2015-01-01

    Abnormality in cerebral blood flow (CBF) distribution can lead to hypoxic-ischemic cerebral damage in newborn infants. The aim of the study was to investigate minimally invasive approaches to measure CBF by comparing simultaneous (15)O-water positron emission tomography (PET) and single TI pulsed...

  11. Magnetic resonance imaging of aneurysmal subarachnoid hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, Toshihide; Shimosegawa, Eku; Inugami, Atsushi; Shishido, Fumio; Fujita, Hideaki; Ito, Hiroshi; Uemura, Kazuo; Yasui, Nobuyuki (Research Inst. of Brain and Blood Vessels, Akita (Japan))

    1991-11-01

    Magnetic resonance imaging of subarachnoid hemorrhage (SAH) due to aneurysm rupture was evaluated in relation to CT findings in nine patients. Six patients were studied within 3 days and the other three patients were studied 4 to 6 days from the ictus of SAH using a 0.5 Tesla superconducting unit. In all of the patients, hematoma in the subarachnoid space and ventricles was demonstrated by the proton density-weighted spin echo sequence, which showed that bloody cerebrospinal fluid (CSF) had a higher signal intensity than brain tissue or normal CSF. Magnetic resonance imaging was more sensitive in detecting SAH and more informative as to the site of the ruptured aneurysm than CT. Despite some limitations in applying it to patients with acute SAH, magnetic resonace imaging has clear advantages in the diagnosis of SAH. (author).

  12. The working principle of magnetic resonance therapy

    CERN Document Server

    Brizhik, Larissa; Fermi, Enrico

    2015-01-01

    In this paper we describe briefly the basic aspects of magnetic resonance therapy, registered as TMR therapy. Clinical studies have shown that application of this therapy significantly accelerates wound healing and, in particular, healing of the diabetic foot disease. To understand the working principle of this therapy, we analyze relevant to it biological effects produced by magnetic fields. Based on these data, we show that there is a hierarchy of the possible physical mechanisms, which can produce such effects. The mutual interplay between the mechanisms can lead to a synergetic outcome delayed in time, which can affect the physiological state of the organism. In particular, we show that soliton mediated charge transport during the redox processes in living organisms is sensitive to magnetic fields, so that such fields can facilitate redox processes in particular, and can stimulate the healing effect of the organism in general. This and other non-thermal resonant mechanisms of the biological effects of mag...

  13. Magnetic resonance imaging in inflammatory rheumatoid diseases.

    Science.gov (United States)

    Sudoł-Szopińska, Iwona; Mróz, Joanna; Ostrowska, Monika; Kwiatkowska, Brygida

    2016-01-01

    Magnetic resonance (MR) is used more and more frequently to diagnose changes in the musculoskeletal system in the course of rheumatic diseases, at their initial assessment, for treatment monitoring and for identification of complications. The article presents the history of magnetic resonance imaging, the basic principles underlying its operation as well as types of magnets, coils and MRI protocols used in the diagnostic process of rheumatic diseases. It enumerates advantages and disadvantages of individual MRI scanners. The principles of MRI coil operation are explained, and the sequences used for MR image analysis are described, particularly in terms of their application in rheumatology, including T1-, T2-, PD-weighted, STIR/TIRM and contrast-enhanced T1-weighted images. Furthermore, views on the need to use contrast agents to optimise diagnosis, particularly in synovitis-like changes, are presented. Finally, methods for the assessment of MR images are listed, including the semi-quantitative method by RAMRIS and quantitative dynamic examination.

  14. Magnetic resonance imaging by using nano-magnetic particles

    Energy Technology Data Exchange (ETDEWEB)

    Shokrollahi, H., E-mail: Shokrollahi@sutech.ac.ir [Electroceramics Group, Department of Materials Science and Engineering, Shiraz University of Technology, Shiraz (Iran, Islamic Republic of); Khorramdin, A. [Electroceramics Group, Department of Materials Science and Engineering, Shiraz University of Technology, Shiraz (Iran, Islamic Republic of); Isapour, Gh. [Department of Materials and Engineering, Hakim Sabzevari University (Iran, Islamic Republic of)

    2014-11-15

    Magnetism and magnetic materials play a major role in various biological applications, such as magnetic bioseparation, magnetic resonance imaging (MRI), hyperthermia treatment of cancer and drug delivery. Among these techniques, MRI is a powerful method not only for diagnostic radiology but also for therapeutic medicine that utilizes a magnetic field and radio waves. Recently, this technique has contributed greatly to the promotion of the human quality life. Thus, this paper presents a short review of the physical principles and recent advances of MRI, as well as providing a summary of the synthesis methods and properties of contrast agents, like different core materials and surfactants. - Highlights: • This paper studies the physics of MRI as a powerful diagnostic technique. • MRI uses the differentiation between healthy and pathological tissues. • The relaxation times can be shortened by the use of a magnetic contrast agent. • The magnetic nanoparticles act as contrast agents, helping to increase the resolution. • Different synthesis methods can influence the magnetic resonance behavior.

  15. [Magnetic resonance compatibility research for coronary mental stents].

    Science.gov (United States)

    Wang, Ying; Liu, Li; Wang, Shuo; Shang, Ruyao; Wang, Chunren

    2015-01-01

    The objective of this article is to research magnetic resonance compatibility for coronary mental stents, and to evaluate the magnetic resonance compatibility based on laboratory testing results. Coronary stents magnetic resonance compatibility test includes magnetically induced displacement force test, magnetically induced torque test, radio frequency induced heating and evaluation of MR image. By magnetic displacement force and torque values, temperature, and image distortion values to determine metal coronary stent demagnetization effect. The methods can be applied to test magnetic resonance compatibility for coronary mental stents and evaluate its demagnetization effect.

  16. Advances in magnetic and optical resonance

    CERN Document Server

    Warren, Warren S

    2013-01-01

    Advances in Magnetic and Optical Resonance contains three articles which review quite fundamentally different aspects of coherent spectroscopy. An enormous variety of effects can be observed when optical and spin resonances are coupled, usually by a combination of radio frequency and laser irradiation. The first article reviews these effects and pays particular attention to developing a theoretical framework which is as similar as possible for the optical and spin cases. Subsequent articles examine deuterium relaxation in molecular solids, and the spatiotemporal growth of multiple spin coheren

  17. Magnetic resonance imaging and its applicability in veterinary cardiology

    OpenAIRE

    Ferreira, José Manuel de Seiça

    2016-01-01

    Magnetic Resonance Imaging (MRI) is a technique whereby images are created by the manipulation of hydrogen atoms in magnetic fields; it is based on the principle of nuclear magnetic resonance (MR), which is non-invasive and non-ionising (Constantine, Shan, Flamm, & Sivananthan, 2004). Cardiac Magnetic Resonance Imaging (CMRI) uses the same principle: application of magnetic-field gradients that are adjusted to highlight desired tissue characteristics, producing a variety of sequences that all...

  18. Validation of magnetic resonance concentration measurements with adiabatic wall temperature measurements

    Science.gov (United States)

    Sayles, Emily L.; Eaton, John K.

    2016-12-01

    Adiabatic wall temperature measurements were obtained in a high subsonic Mach number airflow experiment and compared with concentration measurements near the surface from a low-speed liquid flow experiment. Excellent agreement between the temperature and concentration measurements validates the investigation of turbulent mixing phenomena in compressible gas flows through the study of incompressible liquid flows with magnetic resonance techniques.

  19. Magnetic particle motion in a Poiseuille flow

    NARCIS (Netherlands)

    Haverkort, J.W.; et al, not CWI

    2009-01-01

    The manipulation of magnetic particles in a continuous flow with magnetic fields is central to several biomedical applications, including magnetic cell separation and magnetic drug targeting. A simplified twodimensional 2D equation describing the motion of particles in a planar Poiseuille flow is co

  20. Magnetic resonance imaging based functional imaging in paediatric oncology.

    Science.gov (United States)

    Manias, Karen A; Gill, Simrandip K; MacPherson, Lesley; Foster, Katharine; Oates, Adam; Peet, Andrew C

    2017-02-01

    Imaging is central to management of solid tumours in children. Conventional magnetic resonance imaging (MRI) is the standard imaging modality for tumours of the central nervous system (CNS) and limbs and is increasingly used in the abdomen. It provides excellent structural detail, but imparts limited information about tumour type, aggressiveness, metastatic potential or early treatment response. MRI based functional imaging techniques, such as magnetic resonance spectroscopy, diffusion and perfusion weighted imaging, probe tissue properties to provide clinically important information about metabolites, structure and blood flow. This review describes the role of and evidence behind these functional imaging techniques in paediatric oncology and implications for integrating them into routine clinical practice. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Resonantly detecting axion-mediated forces with nuclear magnetic resonance.

    Science.gov (United States)

    Arvanitaki, Asimina; Geraci, Andrew A

    2014-10-17

    We describe a method based on precision magnetometry that can extend the search for axion-mediated spin-dependent forces by several orders of magnitude. By combining techniques used in nuclear magnetic resonance and short-distance tests of gravity, our approach can substantially improve upon current experimental limits set by astrophysics, and probe deep into the theoretically interesting regime for the Peccei-Quinn (PQ) axion. Our method is sensitive to PQ axion decay constants between 10(9) and 10(12) GeV or axion masses between 10(-6) and 10(-3) eV, independent of the cosmic axion abundance.

  2. Sensorineural hearing loss after magnetic resonance imaging

    DEFF Research Database (Denmark)

    Mollasadeghi, Abolfazl; Mehrparvar, Amir Houshang; Atighechi, Saeid

    2013-01-01

    Magnetic resonance imaging (MRI) devices produce noise, which may affect patient's or operators' hearing. Some cases of hearing impairment after MRI procedure have been reported with different patterns (temporary or permanent, unilateral or bilateral, with or without other symptoms like tinnitus)......). In this report, a case of bilateral sensorineural hearing loss in an otherwise healthy patient underwent brain MRI was described. The patient's hearing loss was accompanied with tinnitus and was not improved after 3 months of followup.......Magnetic resonance imaging (MRI) devices produce noise, which may affect patient's or operators' hearing. Some cases of hearing impairment after MRI procedure have been reported with different patterns (temporary or permanent, unilateral or bilateral, with or without other symptoms like tinnitus...

  3. High speed functional magnetic resonance imaging

    CERN Document Server

    Gibson, A M

    2002-01-01

    The work in this thesis has been undertaken by the except where indicated by reference, within the Magnetic Resonance Centre at the University of Nottingham during the period from October 1998 to October 2001. This thesis documents the implementation and application of a novel high-speed imaging technique, the multi-slice, echo shifted, echo planar imaging technique. This was implemented on the Nottingham 3 T imaging system, for functional magnetic resonance imaging. The technique uses echo shifting over the slices in a multi-slice echo planar imaging acquisition scheme, making the echo time longer than the repetition time per slice. This allows for rapid volumar sampling of the blood oxygen level dependent effect in the human brain. The new high-speed technique was used to investigate the variability of measuring the timing differences between haemodynamic responses, at the same cortical location, to simple cued motor tasks. The technique was also used in an investigation into motor cortex functional connect...

  4. Magnetic resonance imaging findings in tuberculous meningoencephalitis

    Energy Technology Data Exchange (ETDEWEB)

    Pui, M.H.; Memon, W.A. [Aga Khan Univ. Hospital, Dept. of Radiology, Karachi (Pakistan)

    2001-02-01

    To evaluate the efficacy of magnetic resonance imaging (MRI) for distinguishing tuberculosis from other types of meningoencephalitis. MRIs of 100 patients with tuberculous (50), pyogenic (33), viral (14), or fungal (3) meningoencephalitis were analyzed independently by 2 radiologists. Number, size, location, signal characteristics, surrounding edema, and contrast enhancement pattern of nodular lesions; location and pattern of meningeal enhancement; extent of infarct or encephalitis and hydrocephalus were evaluated. Contrast-enhancing nodular lesions were detected in patients with tuberculous (43 of 50 patients), pyogenic (9 of 33), and fungal (3 of 3) infections. No nodules were detected in patients with viral meningoencephalitis. Using the criteria of 1 or more solid rim or homogeneously enhancing nodules smaller than 2 cm, the sensitivity, specificity and accuracy for diagnosing tuberculous meningitis were 86.0%, 90.0% and 88.0%, respectively. Magnetic resonance imaging is useful in distinguishing tuberculous from pyogenic, viral and fungal meningoencephalitis. (author)

  5. Measurement of myocardial perfusion using magnetic resonance

    DEFF Research Database (Denmark)

    Fritz-Hansen, T.; Jensen, L.T.; Larsson, H.B.;

    2008-01-01

    Cardiac magnetic resonance imaging (MRI) has evolved rapidly. Recent developments have made non-invasive quantitative myocardial perfusion measurements possible. MRI is particularly attractive due to its high spatial resolution and because it does not involve ionising radiation. This paper review...... myocardial perfusion imaging with MR contrast agents: methods, validation and experiences from clinical studies. Unresolved issues still restrict the use of these techniques to research although clinical applications are within reach Udgivelsesdato: 2008/12/8......Cardiac magnetic resonance imaging (MRI) has evolved rapidly. Recent developments have made non-invasive quantitative myocardial perfusion measurements possible. MRI is particularly attractive due to its high spatial resolution and because it does not involve ionising radiation. This paper reviews...

  6. Measurement of myocardial perfusion using magnetic resonance

    DEFF Research Database (Denmark)

    Fritz-Hansen, T.; Jensen, L.T.; Larsson, H.B.

    2008-01-01

    Cardiac magnetic resonance imaging (MRI) has evolved rapidly. Recent developments have made non-invasive quantitative myocardial perfusion measurements possible. MRI is particularly attractive due to its high spatial resolution and because it does not involve ionising radiation. This paper reviews...... myocardial perfusion imaging with MR contrast agents: methods, validation and experiences from clinical studies. Unresolved issues still restrict the use of these techniques to research although clinical applications are within reach Udgivelsesdato: 2008/12/8...

  7. Introduction to Magnetic Resonance Imaging Techniques

    OpenAIRE

    2009-01-01

    It is quite possible to acquire images with an MR scanner without understanding the principles behind it, but choosing the best parameters and methods, and interpreting images and artifacts, requires understanding. This text serves as an introduction to magnetic resonance imaging techniques. It is aimed at beginners in possession of only a minimal level of technical expertise, yet it introduces aspects of MR that are typically considered technically challenging. The notes were written in conn...

  8. Magnetic resonance in diagnosis of ureterocele

    Energy Technology Data Exchange (ETDEWEB)

    Nascimento, Humberto do; Hachul, Mauricio; Macedo Junior, Antonio [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Div. de Urologia]. E-mail: humbertojr1@aol.com

    2003-05-15

    Ultrasonography is the main non-invasive technique for screening of ureterocele, but presents some difficulties for its diagnosis. Other supplementary diagnostic methods have the disadvantage of being invasive or using ionizing radiation. Magnetic resonance (MR) has a high sensitivity for diagnosing urinary tract malformations in adults and children. We report one case of ureterocele in a 1-year old child with the purpose of presenting its diagnosis through MR. (author)

  9. "PALPATION BY IMAGING": MAGNETIC RESONANCE ELASTOGRAPHY

    Institute of Scientific and Technical Information of China (English)

    Lei Xu; Pei-yi Gao

    2006-01-01

    Elasticity is an important physical property of human tissues.There is a tremendous difference in elasticity between normal and pathological tissues.Noninvasive evaluation of the elasticity of human tissues would be valuable for clinical practice.Magnetic resonance elastography(MRE)is a recently developed noninvasive imaging technique that can directly visualize and quantitatively measure tissue elasticity.This article reviewed the MRE technique and its current status.

  10. Perfusion magnetic resonance imaging of the liver

    Institute of Scientific and Technical Information of China (English)

    Choon; Hua; Thng; Tong; San; Koh; David; J; Collins; Dow; Mu; Koh

    2010-01-01

    Perfusion magnetic resonance imaging (MRI) studies quantify the microcirculatory status of liver parenchyma and liver lesions, and can be used for the detection of liver metastases, assessing the effectiveness of antiangiogenic therapy, evaluating tumor viability after anticancer therapy or ablation, and diagnosis of liver cirrhosis and its severity. In this review, we discuss the basic concepts of perfusion MRI using tracer kinetic modeling, the common kinetic models applied for analyses, the MR scanning t...

  11. Magnetic resonance acoustic radiation force imaging.

    Science.gov (United States)

    McDannold, Nathan; Maier, Stephan E

    2008-08-01

    Acoustic radiation force impulse imaging is an elastography method developed for ultrasound imaging that maps displacements produced by focused ultrasound pulses systematically applied to different locations. The resulting images are "stiffness weighted" and yield information about local mechanical tissue properties. Here, the feasibility of magnetic resonance acoustic radiation force imaging (MR-ARFI) was tested. Quasistatic MR elastography was used to measure focal displacements using a one-dimensional MRI pulse sequence. A 1.63 or 1.5 MHz transducer supplied ultrasound pulses which were triggered by the magnetic resonance imaging hardware to occur before a displacement-encoding gradient. Displacements in and around the focus were mapped in a tissue-mimicking phantom and in an ex vivo bovine kidney. They were readily observed and increased linearly with acoustic power in the phantom (R2=0.99). At higher acoustic power levels, the displacement substantially increased and was associated with irreversible changes in the phantom. At these levels, transverse displacement components could also be detected. Displacements in the kidney were also observed and increased after thermal ablation. While the measurements need validation, the authors have demonstrated the feasibility of detecting small displacements induced by low-power ultrasound pulses using an efficient magnetic resonance imaging pulse sequence that is compatible with tracking of a dynamically steered ultrasound focal spot, and that the displacement increases with acoustic power. MR-ARFI has potential for elastography or to guide ultrasound therapies that use low-power pulsed ultrasound exposures, such as drug delivery.

  12. Fokker-Planck formalism in magnetic resonance simulations.

    Science.gov (United States)

    Kuprov, Ilya

    2016-09-01

    This paper presents an overview of the Fokker-Planck formalism for non-biological magnetic resonance simulations, describes its existing applications and proposes some novel ones. The most attractive feature of Fokker-Planck theory compared to the commonly used Liouville - von Neumann equation is that, for all relevant types of spatial dynamics (spinning, diffusion, stationary flow, etc.), the corresponding Fokker-Planck Hamiltonian is time-independent. Many difficult NMR, EPR and MRI simulation problems (multiple rotation NMR, ultrafast NMR, gradient-based zero-quantum filters, diffusion and flow NMR, off-resonance soft microwave pulses in EPR, spin-spin coupling effects in MRI, etc.) are simplified significantly in Fokker-Planck space. The paper also summarises the author's experiences with writing and using the corresponding modules of the Spinach library - the methods described below have enabled a large variety of simulations previously considered too complicated for routine practical use.

  13. Magnetic Resonance Velocimetry analysis of an angled impinging jet

    Science.gov (United States)

    Irhoud, Alexandre; Benson, Michael; Verhulst, Claire; van Poppel, Bret; Elkins, Chris; Helmer, David

    2016-11-01

    Impinging jets are used to achieve high heat transfer rates in applications ranging from gas turbine engines to electronics. Despite the importance and relative simplicity of the geometry, simulations historically fail to accurately predict the flow behavior in the vicinity of the flow impingement. In this work, we present results from a novel experimental technique, Magnetic Resonance Velocimetry (MRV), which measures three-dimensional time-averaged velocity without the need for optical access. The geometry considered in this study is a circular jet angled at 45 degrees and impinging on a flat plate, with a separation of approximately seven jet diameters between the jet exit and the impingement location. Two flow conditions are considered, with Reynolds numbers of roughly 800 and 14,000. Measurements from the MRV experiment are compared to predictions from Reynolds Averaged Navier Stokes (RANS) simulations, thus demonstrating the utility of MRV for validation of numerical analyses of impinging jet flow.

  14. Magnetic Heat Pump Containing Flow Diverters

    Science.gov (United States)

    Howard, Frank S.

    1995-01-01

    Proposed magnetic heat pump contains flow diverters for suppression of undesired flows. If left unchecked, undesired flows mix substantial amounts of partially heated and partially cooled portions of working fluid, effectively causing leakage of heat from heated side to cooled side. By reducing leakage of heat, flow diverters increase energy efficiency of magnetic heat pump, potentially offering efficiency greater than compressor-driven refrigerator.

  15. Magnetic Heat Pump Containing Flow Diverters

    Science.gov (United States)

    Howard, Frank S.

    1995-01-01

    Proposed magnetic heat pump contains flow diverters for suppression of undesired flows. If left unchecked, undesired flows mix substantial amounts of partially heated and partially cooled portions of working fluid, effectively causing leakage of heat from heated side to cooled side. By reducing leakage of heat, flow diverters increase energy efficiency of magnetic heat pump, potentially offering efficiency greater than compressor-driven refrigerator.

  16. Electro-Mechanical Resonant Magnetic Field Sensor

    CERN Document Server

    Temnykh, A B; Temnykh, Alexander B.; Lovelace, Richard V. E.

    2002-01-01

    We describe a new type of magnetic field sensor which is termed an Electro-Mechanical Resonant Sensor (EMRS). The key part of this sensor is a small conductive elastic element with low damping rate and therefore a high Q fundamental mode of frequency $f_1$. An AC current is driven through the elastic element which, in the presence of a magnetic field, causes an AC force on the element. When the frequency of the AC current matches the resonant frequency of the element, maximum vibration of the element occurs and this can be measured precisely by optical means. We have built and tested a model sensor of this type using for the elastic element a length of copper wire of diameter 0.030 mm formed into a loop shape. The wire motion was measured using a light emitting diode photo-transistor assembly. This sensor demonstrated a sensitivity better than 0.001G for an applied magnetic field of $ \\sim 1$G and a good selectivity for the magnetic field direction. The sensitivity can be easily improved by a factor of $\\sim ...

  17. Compact low field magnetic resonance imaging magnet: Design and optimization

    Science.gov (United States)

    Sciandrone, M.; Placidi, G.; Testa, L.; Sotgiu, A.

    2000-03-01

    Magnetic resonance imaging (MRI) is performed with a very large instrument that allows the patient to be inserted into a region of uniform magnetic field. The field is generated either by an electromagnet (resistive or superconductive) or by a permanent magnet. Electromagnets are designed as air cored solenoids of cylindrical symmetry, with an inner bore of 80-100 cm in diameter. In clinical analysis of peripheral regions of the body (legs, arms, foot, knee, etc.) it would be better to adopt much less expensive magnets leaving the most expensive instruments to applications that require the insertion of the patient in the magnet (head, thorax, abdomen, etc.). These "dedicated" apparati could be smaller and based on resistive magnets that are manufactured and operated at very low cost, particularly if they utilize an iron yoke to reduce power requirements. In order to obtain good field uniformity without the use of a set of shimming coils, we propose both particular construction of a dedicated magnet, using four independently controlled pairs of coils, and an optimization-based strategy for computing, a posteriori, the optimal current values. The optimization phase could be viewed as a low-cost shimming procedure for obtaining the desired magnetic field configuration. Some experimental measurements, confirming the effectiveness of the proposed approach (construction and optimization), have also been reported. In particular, it has been shown that the adoption of the proposed optimization based strategy has allowed the achievement of good uniformity of the magnetic field in about one fourth of the magnet length and about one half of its bore. On the basis of the good experimental results, the dedicated magnet can be used for MRI of peripheral regions of the body and for animal experimentation at very low cost.

  18. 4D-flow cardiac magnetic resonance-derived vorticity is sensitive marker of left ventricular diastolic dysfunction in patients with mild-to-moderate chronic obstructive pulmonary disease.

    Science.gov (United States)

    Schäfer, Michal; Humphries, Stephen; Stenmark, Kurt R; Kheyfets, Vitaly O; Buckner, J Kern; Hunter, Kendall S; Fenster, Brett E

    2017-04-27

    To investigate the possibility that vorticity assessed by four-dimensional flow cardiac magnetic resonance (4D-Flow CMR) in the left ventricle of patients with mild-to-moderate chronic obstructive pulmonary disease (COPD) is a potential marker of early LV diastolic dysfunction (LVDD) and more sensitive than standard echocardiography, and whether changes in vorticity are associated with quantitative computed tomography (CT) and clinical markers of COPD, and right ventricular (RV) echocardiographic markers indicative of ventricular interdependency. Sixteen COPD patients with presumptive LVDD and 10 controls underwent same-day 4D-Flow CMR and Doppler echocardiography to quantify early and late diastolic vorticity as well as standard evaluation for LVDD. Furthermore, all patients underwent detailed CT analysis for COPD markers including percent emphysema and air trapping. The 4D-Flow CMR derived diastolic vorticity measures were correlated with CT measures, standard clinical and CMR markers, and echocardiographic diastolic RV metrics. Early diastolic vorticity was significantly reduced in COPD patients (P < 0.0001) with normal left ventricular (LV) mass, geometry, systolic function, and no or mild signs of Doppler LVDD when compared with controls. Vorticity significantly differentiated COPD patients without echocardiographic signs of LVDD (n = 11) from controls (P < 0.0001), and from COPD patients with stage I LVDD (n = 5) (P < 0.0180). Vorticity markers significantly correlated with CT computed measures, CMR-derived RV ejection fraction, echocardiographic RV diastolic metrics, and 6-minute walk test. 4D-Flow CMR derived diastolic vorticity is reduced in patients with mild-to-moderate COPD and no or mild signs of LVDD, implying early perturbations in the LV flow domain preceding more obvious mechanical changes (i.e. stiffening and dilation). Furthermore, reduced LV vorticity appears to be driven by COPD induced changes in lung tissue and parallel RV

  19. Application of magnetic resonance techniques for imaging tumour physiology

    Energy Technology Data Exchange (ETDEWEB)

    Stubbs, M. [Saint George' s Hospital Medical School, London (United Kingdom). Dept. of Biochemistry

    1999-07-01

    Magnetic resonance (MR) techniques have the unique ability to measure in vivo the biochemical content of living tissue in the body in a dynamic, non-invasive and non-destructive manner. MR also permits serial investigations of steady-state tumour physiology and biochemistry, as well as the response of a tumour to treatment. Magnetic resonance imaging (MRI), Magnetic resonance spectroscopy (MRS) and a mixture of the two techniques (spectroscopic imaging) allow some physiological parameters, for example pH, to be 'imaged'. Using these methods, information on tissue bioenergetics and phospolipid membrane turnover, pH, hypoxia, oxygenation, and various aspects of vascularity including blood flow, angiogenesis, permeability and vascular volume can be obtained. In addition, MRS methods can be used for monitoring anticancer drugs (e.g. 5FU, ifosfamide) and their metabolites at their sites of action. The role of these state-of-the-art MR methods in imaging tumour physiology and their potential role in the clinic are discussed. (orig.)

  20. Portal biliopathy, magnetic resonance imaging and magnetic resonance cholangiopancreatography findings: a case series

    Science.gov (United States)

    Baskan, Ozdil; Erol, Cengiz; Sahingoz, Yusuf

    2016-01-01

    Portal biliopathy (PB) is a rare disorder, characterized by biliary ductal and gallbladder wall abnormalities seen in patients with portal hypertension. It most commonly occurs due to idiopathic extrahepatic portal vein obstruction (EHPVO). The abnormalities consist mainly of bile duct compression, stenoses, fibrotic strictures and dilation of both extrahepatic and intrahepatic bile ducts, as well as gallbladder varices. PB may mimic cholangiocarcinoma, sclerosing cholangitis, or choledocholithiasis. Misdiagnosis can be avoided using appropriate imaging modalities to prevent complications. We present the magnetic resonance imaging (MRI) and magnetic resonance cholangiography (MRCP) features of three patients with PB. PMID:25216728

  1. Accuracy of magnetic resonance based susceptibility measurements

    Science.gov (United States)

    Erdevig, Hannah E.; Russek, Stephen E.; Carnicka, Slavka; Stupic, Karl F.; Keenan, Kathryn E.

    2017-05-01

    Magnetic Resonance Imaging (MRI) is increasingly used to map the magnetic susceptibility of tissue to identify cerebral microbleeds associated with traumatic brain injury and pathological iron deposits associated with neurodegenerative diseases such as Parkinson's and Alzheimer's disease. Accurate measurements of susceptibility are important for determining oxygen and iron content in blood vessels and brain tissue for use in noninvasive clinical diagnosis and treatment assessments. Induced magnetic fields with amplitude on the order of 100 nT, can be detected using MRI phase images. The induced field distributions can then be inverted to obtain quantitative susceptibility maps. The focus of this research was to determine the accuracy of MRI-based susceptibility measurements using simple phantom geometries and to compare the susceptibility measurements with magnetometry measurements where SI-traceable standards are available. The susceptibilities of paramagnetic salt solutions in cylindrical containers were measured as a function of orientation relative to the static MRI field. The observed induced fields as a function of orientation of the cylinder were in good agreement with simple models. The MRI susceptibility measurements were compared with SQUID magnetometry using NIST-traceable standards. MRI can accurately measure relative magnetic susceptibilities while SQUID magnetometry measures absolute magnetic susceptibility. Given the accuracy of moment measurements of tissue mimicking samples, and the need to look at small differences in tissue properties, the use of existing NIST standard reference materials to calibrate MRI reference structures is problematic and better reference materials are required.

  2. Filling defect artefacts in magnetic resonance urography

    Energy Technology Data Exchange (ETDEWEB)

    Girish, G.; Chooi, W.K.; Morcos, S.K. [Department of Diagnostic Imaging, Northern General Hospital, Sheffield Teaching Hospitals NHS Trust, S5 7AU, Sheffield (United Kingdom)

    2004-01-01

    The aim of this study was to determine the prevalence of filling defect artefacts (FDA) in magnetic resonance urography (MRU). Retrospectively, we assessed MRU examinations of 45 patients with neurogenic bladder dysfunction (21 men, 24 women; mean age 35 years, age range 18-71 years). The MRU was performed 30 min after intramuscular injection of 20 mg frusemide using heavily T2-weighted fast-spin-echo techniques [axial, thick coronal slab, coronal maximum intensity projection (MIP) images] with fat saturation. The images were reviewed by two observers to determine the presence of filling defects and dilatation of pelvicalyceal system and ureters. The filling defects were classified into central, eccentric and complete. Clinical course and plain films were reviewed to determine significance of the detected filling defects. True filling defects were observed in 5 patients (11%) and all due to stones seen on the plain radiograph of the abdomen. Filling defects artefacts (FDAs) were seen in 23 patients (51%; 17 pelvicalyceal system, 17 upper third of ureters, 7 mid ureters and 1 distal ureter). No stones were seen on the plain radiograph of these patients and they had a favourable clinical course for over 24 months. The true filling defects were large in size, eccentric in position and seen in more than one sequence of the MRU examination (axial, n=5; slab, n=5; and MIP, n=4). Four (80%) of the patients with true defects and 21 (91%) of those with FDAs had dilatation of the pelvicalyceal system and ureters. The FDAs were small in size, centrally placed (74%) and always seen in axial images, rarely in slab images (2 cases) and not seen in MIP images. Artefactual filling defects can be seen in MRU examinations. The cause of the FDAs is not fully explained and could be secondary to turbulent and fast flow of the urine. Some of the FDAs seen in the calyces could be due to the tips of the papillae. Awareness of such defects obviates misinterpretation and prevents

  3. Magnetic resonance imaging of valvular heart disease

    DEFF Research Database (Denmark)

    Søndergaard, Lise; Ståhlberg, F; Thomsen, C

    1999-01-01

    The optimum management of patients with valvular heart diseases requires accurate and reproducible assessment of the valvular lesion and its hemodynamic consequences. Magnetic resonance imaging (MRI) techniques, such as volume measurements, signal-void phenomena, and velocity mapping, can be used...... in an integrated approach to gain qualitative and quantitative information on valvular heart disease as well as ventricular dimensions and functions. Thus, MRI may be advantageous to the established diagnostic tools in assessing the severity of valvular heart disease as well as monitoring the lesion and predicting...... the optimal timing for valvular surgery. This paper reviews the validation of these MRI techniques in assessing valvular heart disease and discusses some typical pitfalls of the techniques, including suggestions for solutions.J. Magn. Reson. Imaging 1999;10:627-638....

  4. 76 FR 58281 - Magnetic Resonance Imaging Safety; Public Workshop

    Science.gov (United States)

    2011-09-20

    ... HUMAN SERVICES Food and Drug Administration Magnetic Resonance Imaging Safety; Public Workshop AGENCY... the safe use of magnetic resonance imaging (MRI) and approaches to mitigate risks. The overall goal is...: The Food and Drug Administration (FDA) is announcing a public workshop entitled: ``Magnetic...

  5. Molecular structure and motion in zero field magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Jarvie, T.P.

    1989-10-01

    Zero field magnetic resonance is well suited for the determination of molecular structure and the study of motion in disordered materials. Experiments performed in zero applied magnetic field avoid the anisotropic broadening in high field nuclear magnetic resonance (NMR) experiments. As a result, molecular structure and subtle effects of motion are more readily observed.

  6. Achilles Impingement Tendinopathy on Magnetic Resonance Imaging.

    Science.gov (United States)

    Bullock, Mark J; Mourelatos, Jan; Mar, Alice

    2017-02-28

    Haglund's syndrome is impingement of the retrocalcaneal bursa and Achilles tendon caused by a prominence of the posterosuperior calcaneus. Radiographic measurements are not sensitive or specific for diagnosing Haglund's deformity. Localization of a bone deformity and tendinopathy in the same sagittal section of a magnetic resonance imaging scan can assist with the diagnosis in equivocal cases. The aim of the present cross-sectional study was to determine the prevalence of Haglund's syndrome in patients presenting with Achilles tendinopathy and note any associated findings to determine the criteria for a diagnosis of Haglund's syndrome. We reviewed 40 magnetic resonance imaging scans with Achilles tendinopathy and 19 magnetic resonance imaging scans with Achilles high-grade tears and/or ruptures. Achilles tendinopathy was often in close proximity to the superior aspect of the calcaneal tuberosity, consistent with impingement (67.5%). Patients with Achilles impingement tendinopathy were more often female (p < .04) and were significantly heavier than patients presenting with noninsertional Achilles tendinopathy (p = .014) or Achilles tendon rupture (p = .010). Impingement tendinopathy occurred medially (8 of 20) and centrally (10 of 20) more often than laterally (2 of 20) and was associated with a posterior prominence or hyperconvexity with a loss of calcaneal recess more often than a superior projection (22 of 27 versus 8 of 27; p < .001). Haglund's deformity should be reserved for defining a posterior prominence or hyperconvexity with loss of calcaneal recess because this corresponds with impingement. Achilles impingement tendinopathy might be more appropriate terminology for Haglund's syndrome, because the bone deformity is often subtle. Of the 27 images with Achilles impingement tendinopathy, 10 (37.0%) extended to a location prone to Achilles tendon rupture. Given these findings, insertional and noninsertional Achilles tendinopathy are not mutually

  7. Magnetic resonance in hearing loss and vertigo

    Directory of Open Access Journals (Sweden)

    Manuel Ángel MARTÍN-PÉREZ

    2017-03-01

    Full Text Available Introduction and objective: Hearing loss and vertiginous syndrome represent an important part of the otorhinolaryngology clinic. The role of the radiologist plays in their workup become fundamental. Studies using magnetic resonance imaging (MRI are essential to guide or give the diagnosis in these cases. Method: After performing a retrospective analysis of 456 MRI studies of patients with these symptoms, we conducted a review of the main pathologies recorded that can cause these symptoms. Results: We classify into vascular disorders and other variants, tumor pathology, malformations and inflammatory pathology; We also describe the most relevant findings on MRI and illustrated with examples of our center.

  8. Magnetic Resonance Imaging of Thyroid and Parathyroid

    Directory of Open Access Journals (Sweden)

    Miguel Gonzalo-Domínguez

    2016-11-01

    Full Text Available Introduction: The assessment of the thyroid and parathyroid pathology is usually achieved with ultrasounds. There are several systems of classification that are internationally accepted in neoplastic disease, such as TIRADS system, and there are well-defined patterns for ultrasound imaging in inflammatory disease. Material and methods: However, there are specific needs that require magnetic resonance imaging. We review the main indications of MRI in the evaluation of thyroid and parathyroid in 64 patients and determine which protocols are more appropriate and which sequences are better for a proper characterization. Results: Then we review the semiology obtained by this technique, making correlation with disease processes affecting these cervical structures.

  9. Magnetic resonance spectroscopy studies in migraine

    Energy Technology Data Exchange (ETDEWEB)

    Montagna, P.; Cortelli, P.; Barbiroli, B. (Inst. of Medical Pathology, Univ. of Bologna (Italy))

    1994-06-01

    The authors describe the method of [sup 31]phosphorus magnetic resonance spectroscopy and review the results when it is applied to the study of brain and muscle energy metabolism in migraine subjects. Brain energy metabolism appears to be abnormal in all major subtypes of migraine when measured both during and between attacks. Impaired energy metabolism is also documented in skeletal muscle. It is suggested that migraine is associated with a generalized disorder of mitochondrial oxidative phosphorylation and that this may constitute a threshold for the triggering of migraine attacks. 47 refs., 10 figs., 3 tabs.

  10. Cardiovascular magnetic resonance in systemic hypertension

    Directory of Open Access Journals (Sweden)

    Maceira Alicia M

    2012-06-01

    Full Text Available Abstract Systemic hypertension is a highly prevalent potentially modifiable cardiovascular risk factor. Imaging plays an important role in the diagnosis of underlying causes for hypertension, in assessing cardiovascular complications of hypertension, and in understanding the pathophysiology of the disease process. Cardiovascular magnetic resonance (CMR provides accurate and reproducible measures of ventricular volumes, mass, function and haemodynamics as well as uniquely allowing tissue characterization of diffuse and focal fibrosis. In addition, CMR is well suited for exclusion of common secondary causes for hypertension. We review the current and emerging clinical and research applications of CMR in hypertension.

  11. Cardiovascular magnetic resonance in systemic hypertension

    Science.gov (United States)

    2012-01-01

    Systemic hypertension is a highly prevalent potentially modifiable cardiovascular risk factor. Imaging plays an important role in the diagnosis of underlying causes for hypertension, in assessing cardiovascular complications of hypertension, and in understanding the pathophysiology of the disease process. Cardiovascular magnetic resonance (CMR) provides accurate and reproducible measures of ventricular volumes, mass, function and haemodynamics as well as uniquely allowing tissue characterization of diffuse and focal fibrosis. In addition, CMR is well suited for exclusion of common secondary causes for hypertension. We review the current and emerging clinical and research applications of CMR in hypertension. PMID:22559053

  12. Magnetic resonance images of chronic patellar tendinitis

    Energy Technology Data Exchange (ETDEWEB)

    Bodne, D.; Quinn, S.F.; Murray, W.T.; Cochran, C.; Bolton, T.; Rudd, S.; Lewis, K.; Daines, P.; Bishop, J.

    1988-01-01

    Chronic patellar tendinitis can be a frustrating diagnostic and therapeutic problem. This report evaluates seven tendons in five patients with chronic patellar tendinitis. The etiologies included 'jumper's knee' and Osgood-Schlatter disease. In all cases magnetic resonance images (MRI) showed thickening of the tendon. Some of the tendons had focal areas of thickening which helped establish the etiology. All cases had intratendinous areas of increased signal which, in four cases, proved to be chronic tendon tears. MRI is useful in evaluating chronic patellar tendinitis because it establishes the diagnosis, detects associated chronic tears, and may help determine appropriate rehabilitation. (orig.)

  13. Developments in boron magnetic resonance imaging (MRI)

    Energy Technology Data Exchange (ETDEWEB)

    Schweizer, M.

    1995-11-01

    This report summarizes progress during the past year on maturing Boron-11 magnetic resonance imaging (MRI) methodology for noninvasive determination of BNCT agents (BSH) spatially in time. Three major areas are excerpted: (1) Boron-11 MRI of BSH distributions in a canine intracranial tumor model and the first human glioblastoma patient, (2) whole body Boron-11 MRI of BSH pharmacokinetics in a rat flank tumor model, and (3) penetration of gadolinium salts through the BBB as a function of tumor growth in the canine brain.

  14. Magnetic resonance imaging of musculoaponeurotic fibromatosis

    Energy Technology Data Exchange (ETDEWEB)

    Hawnaur, J.M.; Jenkins, J.P.R.; Isherwood, I. (Manchester Univ. (UK). Dept. of Diagnostic Radiology)

    1990-10-01

    Musculoaponeurotic fibromatosis can be mistaken for soft-tissue sarcoma both clinically and on X-ray computed tomography. Magnetic resonance imaging (MRI) in three patients with this condition enabled the correct diagnosis to be made prospectively in two. The appearance on MRI of a heterogeneous mass with well-defined, predominantly peripheral areas of very low signal intensity due to dense fibrous tissue and areas of medium to high signal intensity corresponding to a more cellular stroma should raise the suspicion of musculoaponeurotic fibromatosis. Cellular areas within the tumour showed moderate enhancement after gadolinium diethylene triamine pentaacetic acid administration. (orig.).

  15. Magnetic resonance imaging of rat fetuses

    Energy Technology Data Exchange (ETDEWEB)

    Igarashi, Yo; Kawanishi, Hiroaki (Imamichi Institute for Animal Reproduction, Ibaraki (Japan)); Hasegawa, Kenichi; Otsu, Shinichi

    1993-06-01

    The internal structures of rat fetuses on day 18.0 of pregnancy were studied by magnetic resonance imaging in 1-mm sagittal slices. Each organ was represented as white to gray images different in tone according to the [sup 1]H proton content and the relaxation time. In solid organs, portions with high cell density were seen as white areas and those with low cell density as gray areas. In the tubular organs, the margins were imaged as white and the lumina as gray. (author).

  16. Fetal magnetic resonance imaging and human genetics

    Energy Technology Data Exchange (ETDEWEB)

    Hengstschlaeger, Markus [Medical Genetics, Obstetrics and Gynecology, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria)]. E-mail: markus.hengstschlaeger@meduniwien.ac.at

    2006-02-15

    The use of fetal magnetic resonance imaging (MRI), in addition to prenatal genetic testing and sonography, has the potential to improve prenatal diagnosis of genetic disorders. MRI plays an important role in the evaluation of fetal abnormalities and malformations. Fetal MRI often enables a differential diagnosis, a determination of the extent of the disorder, the prognosis, and an improvement in therapeutic management. For counseling of parents, as well as to basically understand how genetic aberrations affect fetal development, it is of great importance to correlate different genotypes with fetal MRI data.

  17. Sciatic neuropathy: findings on magnetic resonance neurography

    Science.gov (United States)

    Agnollitto, Paulo Moraes; Chu, Marcio Wen King; Simão, Marcelo Novelino; Nogueira-Barbosa, Marcello Henrique

    2017-01-01

    Injuries of the sciatic nerve are common causes of pain and limitation in the lower limbs. Due to its particular anatomy and its long course, the sciatic nerve is often involved in diseases of the pelvis or leg. In recent years, magnetic resonance neurography has become established as an important tool for the study of peripheral nerves and can be widely applied to the study of the sciatic nerve. Therefore, detailed knowledge of its anatomy and of the most prevalent diseases affecting it is essential to maximizing the accuracy of diagnostic imaging. PMID:28670031

  18. Magnetic resonance imaging of acoustic neuroma

    Energy Technology Data Exchange (ETDEWEB)

    Kashihara, Kengo; Murata, Hideaki; Ito, Haruhide; Onishi, Hiroaki; Kadoya, Masumi; Suzuki, Masayuki.

    1989-03-01

    Thirteen patients with acoustic neuroma were studied on a 1.5T superconductive magnetic resonance (MR) imager. Acoustic neuromas appeared as lower signal intensity than the surrounding brain stem on T1 weighted image (W.I.), and as higher signal intensity on T2 W.I.. Axial and coronal sections of T1 W.I. were very useful in observing the tumor in the auditory canal and in investigating the anatomical relations of the tumor and the surrounding structures. MR imaging is very excellent examination to make early diagnosis of the acoustic neuroma and preoperative anatomical evaluation.

  19. Sensorineural Hearing Loss after Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Abolfazl Mollasadeghi

    2013-01-01

    Full Text Available Magnetic resonance imaging (MRI devices produce noise, which may affect patient’s or operators’ hearing. Some cases of hearing impairment after MRI procedure have been reported with different patterns (temporary or permanent, unilateral or bilateral, with or without other symptoms like tinnitus. In this report, a case of bilateral sensorineural hearing loss in an otherwise healthy patient underwent brain MRI was described. The patient’s hearing loss was accompanied with tinnitus and was not improved after 3 months of followup.

  20. Monitoring angiogenesis using magnetic resonance methods

    DEFF Research Database (Denmark)

    Holm, David Alberg

    2008-01-01

    and the involved signaling molecules. Subsequently, a short review of contrast agents and perfusion measurements is given. Finally, methods for monitoring angiogenesis using magnetic resonance imaging are reviewed. A method for monitoring early stages of angiogenesis as well as the effect of anti......-angiogenic treatment is presented in the first manuscript. In the second and third manuscript, two separate methods of quantifying perfusion, blood volume and vessel permeability are presented. The methods are used to show that drug delivery to a xenografted tumor is plausible and to show possible vascular maturation...

  1. Hair product artifact in magnetic resonance imaging.

    Science.gov (United States)

    Chenji, Sneha; Wilman, Alan H; Mah, Dennell; Seres, Peter; Genge, Angela; Kalra, Sanjay

    2017-01-01

    The presence of metallic compounds in facial cosmetics and permanent tattoos may affect the quality of magnetic resonance imaging. We report a case study describing a signal artifact due to the use of a leave-on powdered hair dye. On reviewing the ingredients of the product, it was found to contain several metallic compounds. In lieu of this observation, we suggest that MRI centers include the use of metal- or mineral-based facial cosmetics or hair products in their screening protocols. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Magnetic resonance imaging in rheumatology. An overview.

    Science.gov (United States)

    Nissenbaum, M A; Adamis, M K

    1994-05-01

    Magnetic resonance (MR) imaging has revolutionized the assessment of pathology involving the musculoskeletal system. The soft tissue contrast, superb resolution, multiplanar acquisition potential, and the ability to monitor physiologic processes combine the best features of other imaging modalities. The sensitivity and specificity of MR imaging for a wide range of disease processes matches or supersedes conventional radiology, nuclear medicine, and clinical examination. This article provides a brief overview of the use of MR imaging for some of the more common clinical situations confronting the rheumatologist.

  3. Cardiac magnetic resonance in clinical cardiology

    Institute of Scientific and Technical Information of China (English)

    Andreas; Kumar; Rodrigo; Bagur

    2015-01-01

    Over the last decades, cardiac magnetic resonance(CMR) has transformed from a research tool to a widely used diagnostic method in clinical cardiology. This method can now make useful, unique contributions to the work-up of patients with ischemic and non-ischemic heart disease. Advantages of CMR, compared to other imaging methods, include very high resolution imaging with a spatial resolution up to 0.5 mm × 0.5 mm in plane, a large array of different imaging sequences to provide in vivo tissue characterization, and radiationfree imaging. The present manuscript highlights the relevance of CMR in the current clinical practice and new perspectives in cardiology.

  4. Magnetic resonance imaging of the cervical region

    Energy Technology Data Exchange (ETDEWEB)

    Tjoerstad, K.; Kaass, B.; Svihus, R.

    1987-11-01

    Magnetic resonance imaging (MRI) of the cervical region was carried out on 139 patients in a ten-month period. 64 patients came from Rogaland Central Hospital and 75 from the rest of Norway. A retrospective questionnaire was filled in by the referring physicians. MRI seems to be of great value in the diagnosis of cervical vertebrogenic myelopathy, multiple sclerosis, syringomyelia, and intraspinal tumors. Besides its diagnostic superiority, at least in patients with cervical myelopathy, MRI has definite economic advantages compared to CT and myelography.

  5. [Magnetic resonance imaging of the temporomandibular joint].

    Science.gov (United States)

    Ros Mendoza, L H; Cañete Celestino, E; Velilla Marco, O

    2008-01-01

    The temporomandibular joint (TMJ) is a small joint with complex anatomy and function. Diverse pathologies with very different symptoms can affect the TMJ. While various imaging techniques such as plain-film radiography and computed tomography can be useful, magnetic resonance imaging's superior contrast resolution reveals additional structures like the articular disk, making this technique essential for accurate diagnosis and treatment planning. We analyze the MRI signs of the different pathologies that can affect the TMJ from the structural and functional points of view.

  6. MRCP. Magnetic resonance cholangiopancreatography; MRCP. Magnetresonanzcholangiopankreatografie

    Energy Technology Data Exchange (ETDEWEB)

    Kinner, Sonja [Wisconsin-Madison Univ., Madison, WI (United States). Dept. of Radiology; Lauenstein, Thomas [Evangelisches Krankenhaus Duesseldorf (Germany). Radiologie

    2016-06-15

    Magnetic resonance cholangiopancreatography (MRCP) is a special MR technique to display and analyze the biliary tract and pancreatic ducts. MRCP sequences are equivalent to endoscopic retrograde cholangiopancreatography (ERCP) for diagnostic purposes due to technical developments of the classical T2 weighted MRCP sequences and the availability of contrast enhanced T1 weighted sequences. Therefore, MRCP plays a fundamental role in the diagnoses of hepatobliary and pancreatic diseases, which are presented in this review article as are technical details of sequence acquisitions and the underlying anatomy.

  7. Magnetic Field Gradient Calibration as an Experiment to Illustrate Magnetic Resonance Imaging

    Science.gov (United States)

    Seedhouse, Steven J.; Hoffmann, Markus M.

    2008-01-01

    A nuclear magnetic resonance (NMR) spectroscopy experiment for the undergraduate physical chemistry laboratory is described that encompasses both qualitative and quantitative pedagogical goals. Qualitatively, the experiment illustrates how images are obtained in magnetic resonance imaging (MRI). Quantitatively, students experience the…

  8. Near-zero-field nuclear magnetic resonance

    CERN Document Server

    Ledbetter, Micah; Blanchard, John; Ring, Hattie; Ganssle, Paul; Appelt, Stephan; Bluemich, Bernhard; Pines, Alex; Budker, Dmitry

    2011-01-01

    We investigate nuclear magnetic resonance (NMR) in near-zero-field, where the Zeeman interaction can be treated as a perturbation to the electron mediated scalar interaction (J-coupling). This is in stark contrast to the high field case, where heteronuclear J-couplings are normally treated as a small perturbation. We show that the presence of very small magnetic fields results in splitting of the zero-field NMR lines, imparting considerable additional information to the pure zero-field spectra. Experimental results are in good agreement with first-order perturbation theory and with full numerical simulation when perturbation theory breaks down. We present simple rules for understanding the splitting patterns in near-zero-field NMR, which can be applied to molecules with non-trivial spectra.

  9. Near-zero-field nuclear magnetic resonance.

    Science.gov (United States)

    Ledbetter, M P; Theis, T; Blanchard, J W; Ring, H; Ganssle, P; Appelt, S; Blümich, B; Pines, A; Budker, D

    2011-09-02

    We investigate nuclear magnetic resonance (NMR) in near zero field, where the Zeeman interaction can be treated as a perturbation to the electron mediated scalar interaction (J coupling). This is in stark contrast to the high-field case, where heteronuclear J couplings are normally treated as a small perturbation. We show that the presence of very small magnetic fields results in splitting of the zero-field NMR lines, imparting considerable additional information to the pure zero-field spectra. Experimental results are in good agreement with first-order perturbation theory and with full numerical simulation when perturbation theory breaks down. We present simple rules for understanding the splitting patterns in near-zero-field NMR, which can be applied to molecules with nontrivial spectra.

  10. Clinical applications of cardiovascular magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Marcu, C.B.; Beek, A.M.; Van Rossum, A.C. [Hospital of Saint Raphael, Cardiac Diagnostic Unit, New Haven, CT (United States)], E-mail: bogmarcu@pol.net

    2006-10-15

    Cardiovascular magnetic resonance imaging (MRI) has evolved from an effective research tool into a clinically proven, safe and comprehensive imaging modality. It provides anatomic and functional information in acquired and congenital heart disease and is the most precise technique for quantification of ventricular volumes, function and mass. Owing to its excellent interstudy reproducibility, cardiovascular MRI is the optimal method for assessment of changes in ventricular parameters after therapeutic intervention. Delayed contrast enhancement is an accurate and robust method used in the diagnosis of ischemic and nonischemic cardiomyopathies and less common diseases, such as cardiac sarcoidosis and myocarditis. First-pass magnetic contrast myocardial perfusion is becoming an alternative to radionuclide techniques for the detection of coronary atherosclerotic disease. In this review we outline the techniques used in cardiovascular MRI and discuss the most common clinical applications. (author)

  11. Nanoscale nuclear magnetic resonance with chemical resolution

    Science.gov (United States)

    Aslam, Nabeel; Pfender, Matthias; Neumann, Philipp; Reuter, Rolf; Zappe, Andrea; Fávaro de Oliveira, Felipe; Denisenko, Andrej; Sumiya, Hitoshi; Onoda, Shinobu; Isoya, Junichi; Wrachtrup, Jörg

    2017-07-01

    Nuclear magnetic resonance (NMR) spectroscopy is a key analytical technique in chemistry, biology, and medicine. However, conventional NMR spectroscopy requires an at least nanoliter-sized sample volume to achieve sufficient signal. We combined the use of a quantum memory and high magnetic fields with a dedicated quantum sensor based on nitrogen vacancy centers in diamond to achieve chemical shift resolution in 1H and 19F NMR spectroscopy of 20-zeptoliter sample volumes. We demonstrate the application of NMR pulse sequences to achieve homonuclear decoupling and spin diffusion measurements. The best measured NMR linewidth of a liquid sample was ~1 part per million, mainly limited by molecular diffusion. To mitigate the influence of diffusion, we performed high-resolution solid-state NMR by applying homonuclear decoupling and achieved a 20-fold narrowing of the NMR linewidth.

  12. Enhancement of magnetic resonance imaging with metasurfaces

    CERN Document Server

    Slobozhanyuk, A P; Raaijmakers, A J E; Berg, C A T van den; Kozachenko, A V; Dubrovina, I A; Melchakova, I V; Kivshar, Yu S; Belov, P A

    2015-01-01

    Magnetic resonance imaging (MRI) is the cornerstone technique for diagnostic medicine, biology, and neuroscience. This imaging method is highly innovative, noninvasive and its impact continues to grow. It can be used for measuring changes in the brain after enhanced neural activity, detecting early cancerous cells in tissue, as well as for imaging nanoscale biological structures, and controlling fluid dynamics, and it can be beneficial for cardiovascular imaging. The MRI performance is characterized by a signal-to-noise ratio, however the spatial resolution and image contrast depend strongly on the scanner design. Here, we reveal how to exploit effectively the unique properties of metasurfaces for the substantial improvement of MRI efficiency. We employ a metasurface created by an array of wires placed inside the MRI scanner under an object, and demonstrate a giant enhancement of the magnetic field by means of subwavelength near-field manipulation with the metasurface, thus strongly increasing the scanner sen...

  13. Plasmon coupling of magnetic resonances in an asymmetric gold semishell

    Science.gov (United States)

    Ye, Jian; Kong, Yan; Liu, Cheng

    2016-05-01

    The generation of magnetic dipole resonances in metallic nanostructures is of great importance for constructing near-zero or even negative refractive index metamaterials. Commonly, planar two-dimensional (2D) split-ring resonators or relevant structures are basic elements of metamaterials. In this work, we introduce a three-dimensional (3D) asymmetric Au semishell composed of two nanocups with a face-to-face geometry and demonstrate two distinct magnetic resonances spontaneously in the visible-near infrared optical wavelength regime. These two magnetic resonances are from constructive and destructive hybridization of magnetic dipoles of individual nanocups in the asymmetric semishell. In contrast, complete cancellation of magnetic dipoles in the symmetric semishell leads to only a pronounced electric mode with near-zero magnetic dipole moment. These 3D asymmetric resonators provide new ways for engineering hybrid resonant modes and ultra-high near-field enhancement for the design of 3D metamaterials.

  14. Shear flow effects on double tearing mode global magnetic reconnection

    CERN Document Server

    Voslion, Thibaut; Beyer, Peter; Yagi, Masatoshi; Benkadda, Sadruddin; Garbet, Xavier; Itoh, Kimitaka; Itoh, Sanae-I

    2009-01-01

    The dynamics of a global reconnection in the presence of a poloidal shear flow which is located in between magnetic islands is investigated. Different linear regimes are identified according to the value of the resistivity and the distance between the low-order resonant surfaces. It is found that the presence of a small shear flow affects and significantly delays the global reconnection processes. It is shown that this delay is linked to a breaking of symmetry imposed by the existence of the shear flow and the generation of a mean poloidal flow in the resistive layers.

  15. Functional imaging of plants: A nuclear magnetic resonance study of a cucumber plant

    NARCIS (Netherlands)

    Scheenen, T.; Heemskerk, A.; Jager, de A.; Vergeldt, F.J.; As, van H.

    2002-01-01

    Functional magnetic resonance imaging was used to study transients of biophysical parameters in a cucumber plant in response to environmental changes. Detailed flow imaging experiments showed the location of xylem and phloem in the stem and the response of the following flow characteristics to the

  16. Magnetic resonance imaging findings in adnexial torsion

    Energy Technology Data Exchange (ETDEWEB)

    Trindade, Ronald Meira Castro; Quadros, Marianne Siquara de [Hospital Albert Einstein, Sao Paulo, SP (Brazil). Instituto de Ensino e Pesquisa], e-mail: rtrindade@einstein.br; Baroni, Ronaldo Hueb; Rosemberg, Michelle; Racy, Marcelo de Castro Jorge; Tachibana, Adriano [Hospital Albert Einstein, Sao Paulo, SP (Brazil); Funari, Marcelo Buarque de Gusmao [Hospital Albert Einstein, Sao Paulo, SP (Brazil). Imaging Service

    2010-01-15

    Adnexial torsion is an unusual event, but a major cause of abdominal pain in women. It is often associated with ovarian tumor or cyst, but can occur in normal ovaries, especially in children. The twisting of adnexial structures may involve the ovary or tube, but frequently affects both. In most cases, it is unilateral, with slight predilection for the right size. In imaging findings, increased ovarian volume and adnexial masses are observed, with reduced or absent vascularisation. In cases of undiagnosed or untreated complete twist, hemorrhagic necrosis may occur leading to complications; in that, peritonitis is the most frequent. Early diagnosis helps preventing irreversible damage with conservative treatment, thereby saving the ovary. Limitations in performing physical examination, possible inconclusive results in ultrasound and exposure to radiation in computed tomography makes magnetic resonance imaging a valuable tool in emergency assessment of gynecological diseases. The objective of this study was to report two confirmed cases of adnexial twist, emphasizing the contribution of magnetic resonance imaging in the diagnosis of this condition. (author)

  17. Magnetic Resonance Imaging Methods in Soil Science

    Science.gov (United States)

    Pohlmeier, A.; van Dusschoten, D.; Blümler, P.

    2009-04-01

    Magnetic Resonance Imaging (MRI) is a powerful technique to study water content, dynamics and transport in natural porous media. However, MRI systems and protocols have been developed mainly for medical purposes, i.e. for media with comparably high water contents and long relaxation times. In contrast, natural porous media like soils and rocks are characterized by much lower water contents, typically 0 benefit. Three strategies can be applied for the monitoring of water contents and dynamics in natural porous media: i) Dedicated high-field scanners (with vertical bore) allowing stronger gradients and faster switching so that shorter echo times can be realized. ii) Special measurement sequences using ultrashort rf- and gradient-pulses like single point imaging derivates (SPI, SPRITE)(1) and multi-echo methods, which monitor series of echoes and allow for extrapolation to zero time(2). Hence, the loss of signal during the first echo period may be compensated to determine the initial magnetization (= water content) as well as relaxation time maps simultaneously. iii) Finally low field( strategies will be given. References 1) Pohlmeier et al. Vadose Zone J. 7, 1010-1017 (2008) 2) Edzes et al., Magn. Res. Imag. 16, 185-196 (1998) 3) Raich H, and Blümler P, Concepts in Magn. Reson. B 23B, 16-25 (2004) 4) Pohlmeier et al. Magn. Res. Imag. doi:10.1016/j.mri.2008.06.007 (2008)

  18. Magnetic resonance imaging of the bone marrow

    Energy Technology Data Exchange (ETDEWEB)

    Baur-Melnyk, Andrea (ed.) [Klinikum der Univ. Muenchen (Germany). Inst. fuer Klinische Radiologie

    2013-08-01

    The first book devoted to MRI of the bone marrow. Describes the MRI appearances of normal bone marrows and the full range of bone marrow disorders. Discusses the role of advanced MRI techniques and contrast enhancement. On account of its unrivalled imaging capabilities and sensitivity, magnetic resonance imaging (MRI) is considered the modality of choice for the investigation of physiologic and pathologic processes affecting the bone marrow. This book describes the MRI appearances of both the normal bone marrow, including variants, and the full range of bone marrow disorders. Detailed discussion is devoted to malignancies, including multiple myeloma, lymphoma, chronic myeloproliferative disorders, leukemia, and bone metastases. Among the other conditions covered are benign and malignant compression fractures, osteonecrosis, hemolytic anemia, Gaucher's disease, bone marrow edema syndrome, trauma, and infective and non-infective inflammatory disease. Further chapters address the role of MRI in assessing treatment response, the use of contrast media, and advanced MRI techniques. Magnetic Resonance Imaging of the Bone Marrow represents an ideal reference for both novice and experienced practitioners.

  19. Magnetic Resonance Imaging Evaluation of Cardiac Masses

    Energy Technology Data Exchange (ETDEWEB)

    Braggion-Santos, Maria Fernanda, E-mail: ferbraggion@yahoo.com.br [Divisão de Cardiologia do Departamento de Clínica Médica - Hospital das Clínicas - Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Hospital Universitário - Universidade de Heidelberg, Heidelberg (Germany); Koenigkam-Santos, Marcel [Centro de Ciências das Imagens e Física Médica - Hospital das Clínicas - Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Hospital Universitário - Universidade de Heidelberg, Heidelberg (Germany); Teixeira, Sara Reis [Centro de Ciências das Imagens e Física Médica - Hospital das Clínicas - Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Volpe, Gustavo Jardim [Divisão de Cardiologia do Departamento de Clínica Médica - Hospital das Clínicas - Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Divisão de Cardiologia - Universidade Johns Hopkins, Baltimore (United States); Trad, Henrique Simão [Centro de Ciências das Imagens e Física Médica - Hospital das Clínicas - Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Schmidt, André [Divisão de Cardiologia do Departamento de Clínica Médica - Hospital das Clínicas - Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil)

    2013-09-15

    Cardiac tumors are extremely rare; however, when there is clinical suspicion, proper diagnostic evaluation is necessary to plan the most appropriate treatment. In this context, cardiovascular magnetic resonance imaging (CMRI) plays an important role, allowing a comprehensive characterization of such lesions. To review cases referred to a CMRI Department for investigation of cardiac and paracardiac masses. To describe the positive case series with a brief review of the literature for each type of lesion and the role of cardiovascular magnetic resonance imaging in evaluation. Between August 2008 and December 2011, all cases referred for CMRI with suspicion of tumor involving the heart were reviewed. Cases with positive histopathological diagnosis, clinical evolution or therapeutic response compatible with the clinical suspicion and imaging findings were selected. Among the 13 cases included in our study, eight (62%) had histopathological confirmation. We describe five benign tumors (myxomas, rhabdomyoma and fibromas), five malignancies (sarcoma, lymphoma, Richter syndrome involving the heart and metastatic disease) and three non-neoplastic lesions (pericardial cyst, intracardiac thrombus and infectious vegetation). CMRI plays an important role in the evaluation of cardiac masses of non-neoplastic and neoplastic origin, contributing to a more accurate diagnosis in a noninvasive manner and assisting in treatment planning, allowing safe clinical follow-up with good reproducibility.

  20. Clinical application of functional magnetic resonance imaging

    CERN Document Server

    Alwatban, A Z W

    2002-01-01

    The work described in this thesis was carried out at the Magnetic Resonance Centre of the University of Nottingham during the time from May 1998 to April 2001, and is the work of the except where indicated by reference. The main source of signal changes in functional magnetic resonance imaging (fMRJ) is the fluctuation of paramagnetic deoxyhaemoglobin in the venous blood during different states of functional performance. For the work of this thesis, fMRI studies were carried out using a 3 T MR system with an echo planar imaging (EPI) pulse sequence. Hearing research utilising fMRI has been previously reported in normal subjects. Hearing fMRI is normally performed by stimulating the auditory cortex via an acoustic task presentation such as music, tone, etc. However, performing the same research on deaf subjects requires special equipment to be designed to allow direct stimulation of the auditory nerve. In this thesis, a new method of direct electrical stimulation of the auditory nerve is described that uses a ...

  1. Magnetic resonance methods in fetal neurology.

    Science.gov (United States)

    Mailath-Pokorny, M; Kasprian, G; Mitter, C; Schöpf, V; Nemec, U; Prayer, D

    2012-10-01

    Fetal magnetic resonance imaging (MRI) has become an established clinical adjunct for the in-vivo evaluation of human brain development. Normal fetal brain maturation can be studied with MRI from the 18th week of gestation to term and relies primarily on T2-weighted sequences. Recently diffusion-weighted sequences have gained importance in the structural assessment of the fetal brain. Diffusion-weighted imaging provides quantitative information about water motion and tissue microstructure and has applications for both developmental and destructive brain processes. Advanced magnetic resonance techniques, such as spectroscopy, might be used to demonstrate metabolites that are involved in brain maturation, though their development is still in the early stages. Using fetal MRI in addition to prenatal ultrasound, morphological, metabolic, and functional assessment of the fetus can be achieved. The latter is not only based on observation of fetal movements as an indirect sign of activity of the fetal brain but also on direct visualization of fetal brain activity, adding a new component to fetal neurology. This article provides an overview of the MRI methods used for fetal neurologic evaluation, focusing on normal and abnormal early brain development. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. General review of magnetic resonance elastography.

    Science.gov (United States)

    Low, Gavin; Kruse, Scott A; Lomas, David J

    2016-01-28

    Magnetic resonance elastography (MRE) is an innovative imaging technique for the non-invasive quantification of the biomechanical properties of soft tissues via the direct visualization of propagating shear waves in vivo using a modified phase-contrast magnetic resonance imaging (MRI) sequence. Fundamentally, MRE employs the same physical property that physicians utilize when performing manual palpation - that healthy and diseased tissues can be differentiated on the basis of widely differing mechanical stiffness. By performing "virtual palpation", MRE is able to provide information that is beyond the capabilities of conventional morphologic imaging modalities. In an era of increasing adoption of multi-parametric imaging approaches for solving complex problems, MRE can be seamlessly incorporated into a standard MRI examination to provide a rapid, reliable and comprehensive imaging evaluation at a single patient appointment. Originally described by the Mayo Clinic in 1995, the technique represents the most accurate non-invasive method for the detection and staging of liver fibrosis and is currently performed in more than 100 centers worldwide. In this general review, the mechanical properties of soft tissues, principles of MRE, clinical applications of MRE in the liver and beyond, and limitations and future directions of this discipline -are discussed. Selected diagrams and images are provided for illustration.

  3. Indirect magnetic resonance lymphangiography in patients with lymphedema

    Energy Technology Data Exchange (ETDEWEB)

    Lohrmann, Christian [Division of Diagnostic Radiology, Department of Radiology, University Hospital of Freiburg, Hugstetter Strasse 55, D-79106 Freiburg (Germany)]. E-mail: lohrmann@mrs1.ukl.uni-freiburg.de; Foeldi, Etelka [Foeldi Clinic for Lymphology, Hinterzarten, Roesslehofweg 2-6, D-79856 Hinterzarten (Germany); Langer, Mathias [Division of Diagnostic Radiology, Department of Radiology, University Hospital of Freiburg, Hugstetter Strasse 55, D-79106 Freiburg (Germany)

    2006-09-15

    Purpose: To assess the feasibility of indirect magnetic resonance (MR) lymphangiography with intracutaneous injection of gadodiamide, a commercially available, non-ionic, extracellular paramagnetic contrast agent for the detection of lymphatic vessels in patients with lymphedema. Materials and methods: In 2005, three patients with lymphedema of the lower extremities (1 primary, 2 secondary) were referred by the Foeldi Clinic for Lymphology for indirect magnetic resonance lymphangiography. 4.5 mL of gadodiamide and 0.5 mL of mepivacainhydrochloride 1% were injected intracutaneously into the dorsal aspect of each foot. MR imaging was performed with a 1.5-T system equipped with high-performance gradients. For indirect magnetic resonance lymphangiography, a 3D Fast Low Angle Shot (FLASH) sequence (TR/TE: 5.1/1.23; flip angle: 25; matrix: 448 x 448; bandwidth: 330 Hz/pixel; 6/8 rectangular field of view with a maximum dimension of 500 mm; slices: 88; voxel size: 2.0 mm x 1.0 mm x 1.0 mm; acquisition time: 0 min 31 s) was used. Results: Indirect magnetic resonance lymphangiography depicted lymphatic vessels of the lower and upper leg, and inguinal lymph nodes in all three patients. After 5 min of contrast material application, concomitant venous enhancement was detected. Collateral vessels with dermal back-flow were seen in two patients. A lymphocele in the inguinal region with the afferent lymphatic vessel was depicted in one patient. Conclusion: In the presented small study group, indirect magnetic resonance lymphangiography was technically feasible, and no complications were observed after intracutaneous injection of gadodiamide. Visualizing the lymphatic vessels and accompanying complications non-invasively and without the use of radiation, the presented method has the capability to become a routine diagnostic imaging tool in patients with primary and secondary lymphedema. The method is not able to characterize lymph node morphology, but could provide additional

  4. Biological effects of exposure to magnetic resonance imaging: an overview

    OpenAIRE

    Formica Domenico; Silvestri Sergio

    2004-01-01

    Abstract The literature on biological effects of magnetic and electromagnetic fields commonly utilized in magnetic resonance imaging systems is surveyed here. After an introduction on the basic principles of magnetic resonance imaging and the electric and magnetic properties of biological tissues, the basic phenomena to understand the bio-effects are described in classical terms. Values of field strengths and frequencies commonly utilized in these diagnostic systems are reported in order to a...

  5. Oxygen challenge magnetic resonance imaging in healthy human volunteers.

    Science.gov (United States)

    Dani, Krishna A; Moreton, Fiona C; Santosh, Celestine; Lopez, Rosario; Brennan, David; Schwarzbauer, Christian; Goutcher, Colin; O'Hare, Kevin; Macrae, I Mhairi; Muir, Keith W

    2017-01-01

    Oxygen challenge imaging involves transient hyperoxia applied during deoxyhaemoglobin sensitive (T2*-weighted) magnetic resonance imaging and has the potential to detect changes in brain oxygen extraction. In order to develop optimal practical protocols for oxygen challenge imaging, we investigated the influence of oxygen concentration, cerebral blood flow change, pattern of oxygen administration and field strength on T2*-weighted signal. Eight healthy volunteers underwent multi-parametric magnetic resonance imaging including oxygen challenge imaging and arterial spin labelling using two oxygen concentrations (target FiO2 of 100 and 60%) administered consecutively (two-stage challenge) at both 1.5T and 3T. There was a greater signal increase in grey matter compared to white matter during oxygen challenge (p challenge imaging. Reductions in cerebral blood flow did not obscure the T2*-weighted signal increases. In conclusion, the optimal protocol for further study should utilise target FiO2 = 100% during a single oxygen challenge. Imaging at both 1.5T and 3T is clinically feasible.

  6. Ferromagnetic resonance of particulate magnetic recording tapes

    Science.gov (United States)

    Netzelmann, U.

    1990-08-01

    The room-temperature ferromagnetic resonance (FMR) spectra of γ-Fe2O3, CrO2, and barium ferrite particulate magnetic recording tapes have been measured at microwave frequencies of 9.35 and 35 GHz for various orientations of the static and high-frequency magnetic fields with respect to the tape. For CrO2 tapes, the influence of the width of the angular distribution of the particle orientations on the FMR spectra has been studied from the nearly isotropic case up to the highly oriented case. Hysteretic behavior for a CrO2 tape as well as the effect of tape calendering for a γ-Fe2O3 tape has been observed by FMR. Experimental results are found to be in reasonable agreement with results of theoretical calculations based on a model of an ellipsoidal single-domain particle with both shape and magnetocrystalline anisotropy. Magnetostatic interaction inside the magnetic film has been introduced by expressing the total magnetostatic energy as a combination of a part dependent on particle shape and a part dependent on the shape of the tape. As a result of a comparison of experimental data with calculated data from the model, the magnetocrystalline easy axis of the CrO2 particles is found to be parallel with the particle axis.

  7. Spatial localization in nuclear magnetic resonance spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Keevil, Stephen F [Department of Medical Physics, Guy' s and St Thomas' NHS Foundation Trust, Guy' s Hospital, London, SE1 9RT (United Kingdom); Division of Imaging Sciences, King' s College London, Guy' s Campus, London, SE1 9RT (United Kingdom)

    2006-08-21

    The ability to select a discrete region within the body for signal acquisition is a fundamental requirement of in vivo NMR spectroscopy. Ideally, it should be possible to tailor the selected volume to coincide exactly with the lesion or tissue of interest, without loss of signal from within this volume or contamination with extraneous signals. Many techniques have been developed over the past 25 years employing a combination of RF coil properties, static magnetic field gradients and pulse sequence design in an attempt to meet these goals. This review presents a comprehensive survey of these techniques, their various advantages and disadvantages, and implications for clinical applications. Particular emphasis is placed on the reliability of the techniques in terms of signal loss, contamination and the effect of nuclear relaxation and J-coupling. The survey includes techniques based on RF coil and pulse design alone, those using static magnetic field gradients, and magnetic resonance spectroscopic imaging. Although there is an emphasis on techniques currently in widespread use (PRESS, STEAM, ISIS and MRSI), the review also includes earlier techniques, in order to provide historical context, and techniques that are promising for future use in clinical and biomedical applications. (topical review)

  8. Multidataset Refinement Resonant Diffraction, and Magnetic Structures.

    Science.gov (United States)

    Attfield, J Paul

    2004-01-01

    The scope of Rietveld and other powder diffraction refinements continues to expand, driven by improvements in instrumentation, methodology and software. This will be illustrated by examples from our research in recent years. Multidataset refinement is now commonplace; the datasets may be from different detectors, e.g., in a time-of-flight experiment, or from separate experiments, such as at several x-ray energies giving resonant information. The complementary use of x rays and neutrons is exemplified by a recent combined refinement of the monoclinic superstructure of magnetite, Fe3O4, below the 122 K Verwey transition, which reveals evidence for Fe(2+)/Fe(3+) charge ordering. Powder neutron diffraction data continue to be used for the solution and Rietveld refinement of magnetic structures. Time-of-flight instruments on cold neutron sources can produce data that have a high intensity and good resolution at high d-spacings. Such profiles have been used to study incommensurate magnetic structures such as FeAsO4 and β-CrPO4. A multiphase, multidataset refinement of the phase-separated perovskite (Pr0.35Y0.07Th0.04Ca0.04Sr0.5)MnO3 has been used to fit three components with different crystal and magnetic structures at low temperatures.

  9. Purely electric and magnetic dipole resonances in metamaterial dielectric resonators through perturbation theory inspired geometries

    CERN Document Server

    Campione, Salvatore; Warne, Larry K; Sinclair, Michael B

    2014-01-01

    In this paper we describe a methodology for tailoring the design of metamaterial dielectric resonators, which represent a promising path toward low-loss metamaterials at optical frequencies. We first describe a procedure to decompose the far field scattered by subwavelength resonators in terms of multipolar field components, providing explicit expressions for the multipolar far fields. We apply this formulation to confirm that an isolated high-permittivity cube resonator possesses frequency separated electric and magnetic dipole resonances, as well as a magnetic quadrupole resonance in close proximity to the electric dipole resonance. We then introduce multiple dielectric gaps to the resonator geometry in a manner suggested by perturbation theory, and demonstrate the ability to overlap the electric and magnetic dipole resonances, thereby enabling directional scattering by satisfying the first Kerker condition. We further demonstrate the ability to push the quadrupole resonance away from the degenerate dipole ...

  10. Perfusion information extracted from resting state functional magnetic resonance imaging.

    Science.gov (United States)

    Tong, Yunjie; Lindsey, Kimberly P; Hocke, Lia M; Vitaliano, Gordana; Mintzopoulos, Dionyssios; Frederick, Blaise deB

    2017-02-01

    It is widely known that blood oxygenation level dependent (BOLD) contrast in functional magnetic resonance imaging (fMRI) is an indirect measure for neuronal activations through neurovascular coupling. The BOLD signal is also influenced by many non-neuronal physiological fluctuations. In previous resting state (RS) fMRI studies, we have identified a moving systemic low frequency oscillation (sLFO) in BOLD signal and were able to track its passage through the brain. We hypothesized that this seemingly intrinsic signal moves with the blood, and therefore, its dynamic patterns represent cerebral blood flow. In this study, we tested this hypothesis by performing Dynamic Susceptibility Contrast (DSC) MRI scans (i.e. bolus tracking) following the RS scans on eight healthy subjects. The dynamic patterns of sLFO derived from RS data were compared with the bolus flow visually and quantitatively. We found that the flow of sLFO derived from RS fMRI does to a large extent represent the blood flow measured with DSC. The small differences, we hypothesize, are largely due to the difference between the methods in their sensitivity to different vessel types. We conclude that the flow of sLFO in RS visualized by our time delay method represents the blood flow in the capillaries and veins in the brain.

  11. Long-term follow-up of cerebral infarction patients with proton magnetic resonance spectroscopy

    DEFF Research Database (Denmark)

    Gideon, P; Sperling, B; Arlien-Søborg, P

    1994-01-01

    ) to the chronic stage (> 6 months) with proton magnetic resonance spectroscopy. Cerebral blood flow was measured with single-photon emission-computed tomography with 99mTc-labeled d,l-hexamethylenepropyleneamine oxime as flow tracer. RESULTS: Lactate was found in all patients in the acute stage of stroke. Lactate......BACKGROUND AND PURPOSE: With proton magnetic resonance spectroscopy it is possible to measure the content of various brain metabolites in vivo, including N-acetylaspartate (which may be used as a neuronal marker), creatine, choline, and lactate. The content of these brain metabolites was measured...... connection between the reduction of cerebral blood flow and the spectroscopic findings in the chronic stage and to some extent the clinical outcome. Studies of larger clinical groups will be necessary to further elucidate the prognostic potential of proton magnetic resonance spectroscopy in human stroke....

  12. Magnetic resonance tracking of fluorescent nanodiamond fabrication

    Science.gov (United States)

    Shames, A. I.; Osipov, V. Yu; Boudou, J. P.; Panich, A. M.; von Bardeleben, H. J.; Treussart, F.; Vul', A. Ya

    2015-04-01

    Magnetic resonance techniques (electron paramagnetic resonance (EPR) and nuclear magnetic resonance (NMR)) are used for tracking the multi-stage process of the fabrication of fluorescent nanodiamonds (NDs) produced by high-energy electron irradiation, annealing, and subsequent nano-milling. Pristine commercial high pressure and high temperature microdiamonds (MDs) with mean size 150 μm contain ~5  ×  1018 spins/g of singlet (S = 1/2) substitutional nitrogen defects P1, as well as sp3 C-C dangling bonds in the crystalline lattice. The half-field X-band EPR clearly shows (by the appearance of the intense ‘forbidden’ g = 4.26 line) that high-energy electron irradiation and annealing of MDs induce a large amount (~5  ×  1017 spins/g) of triplet (S = 1) magnetic centers, which are identified as negatively charged nitrogen vacancy defects (NV-). This is supported by EPR observations of the ‘allowed’ transitions between Zeeman sublevels of the triplet state. After progressive milling of the fluorescent MDs down to an ultrasubmicron scale (≤100 nm), the relative abundance of EPR active NV- defects in the resulting fluorescent NDs (FND) substantially decreases and, vice versa, the content of C-inherited singlet defects correlatively increases. In the fraction of the finest FNDs (mean particle size dried supernatant of ultracentrifuged aqueous dispersion of FNDs, the NV- content is found to be reduced by one order of magnitude whereas the singlet defects content increases up to ~2  ×  1019 spins/g. In addition, another triplet-type defect, which is characterized by the g = 4.00 ‘forbidden’ line, appears. On reduction of the particle size below the 20 nm limit, the ‘allowed’ EPR lines become practically unobservable, whereas the ‘forbidden’ lines remain as a reliable fingerprint of the presence of NV- centers in small ND systems. The same size reduction causes the disappearance of the characteristic hyperfine satellites in the

  13. Applications of nuclear magnetic resonance imaging in process engineering

    Science.gov (United States)

    Gladden, Lynn F.; Alexander, Paul

    1996-03-01

    During the past decade, the application of nuclear magnetic resonance (NMR) imaging techniques to problems of relevance to the process industries has been identified. The particular strengths of NMR techniques are their ability to distinguish between different chemical species and to yield information simultaneously on the structure, concentration distribution and flow processes occurring within a given process unit. In this paper, examples of specific applications in the areas of materials and food processing, transport in reactors and two-phase flow are discussed. One specific study, that of the internal structure of a packed column, is considered in detail. This example is reported to illustrate the extent of new, quantitative information of generic importance to many processing operations that can be obtained using NMR imaging in combination with image analysis.

  14. Gadolinium-enhanced magnetic resonance angiography in brain death

    Science.gov (United States)

    Luchtmann, M.; Beuing, O.; Skalej, M.; Kohl, J.; Serowy, S.; Bernarding, J.; Firsching, R.

    2014-01-01

    Confirmatory tests for the diagnosis of brain death in addition to clinical findings may shorten observation time required in some countries and may add certainty to the diagnosis under specific circumstances. The practicability of Gadolinium-enhanced magnetic resonance angiography to confirm cerebral circulatory arrest was assessed after the diagnosis of brain death in 15 patients using a 1.5 Tesla MRI scanner. In all 15 patients extracranial blood flow distal to the external carotid arteries was undisturbed. In 14 patients no contrast medium was noted within intracerebral vessels above the proximal level of the intracerebral arteries. In one patient more distal segments of the anterior and middle cerebral arteries (A3 and M3) were filled with contrast medium. Gadolinium-enhanced MRA may be considered conclusive evidence of cerebral circulatory arrest, when major intracranial vessels fail to fill with contrast medium while extracranial vessels show normal blood flow.

  15. Surface Coil for Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Beatriz Taimy Ricardo Ferro

    2015-01-01

    Full Text Available Currently Magnetic Resonance Imaging (MRI, has become a vital tool for the clinical diagnosis of various diseases, especially in the Nervisos Central System and the Musculos keletal System. Coils(RF are an essential component in the generation of these images, are responsible for exciting thespins of nuclei in a sample and/or detect the resultant signal coming from them. The use of surface RF coils has increased considerably, because they have a high signal to noise ratio, a parameter that defines the quality of the image. In the present work, there was realized the theoretical design and practical implementation of a circular surface RF coil. The experimental prototype was optimized to be used in the tomograph Giroimag03  built in Medical Biophysics Center

  16. Magnetic resonance imaging in patients with panhypopituitarism

    Energy Technology Data Exchange (ETDEWEB)

    Pozzi Mucelli, R.S. [Ist. di Radiologia, Univ. di Trieste, Ospedale di Cattinara (Italy); Frezza, F. [Ist. di Radiologia, Univ. di Trieste, Ospedale di Cattinara (Italy); Magnaldi, S. [Ist. di Radiologia, Univ. di Trieste, Ospedale di Cattinara (Italy); Proto, G. [Servizio di Endocrinologia, Ospedale Civile di Udine (Italy)

    1992-02-01

    Primary panhypopituitarism consists of functional deficiency of the anterior pituitary lobe, which appears during infancy or adolescence. The magnetic resonance findings in 10 patients with a history of primary hypopituitarism are presented. The findings include: reduced pituitary size in all cases; partially (8 cases) or totally (2 cases) empty sella; thin (4 cases), partially visible (3 cases) or absent (2 cases) pituitary stalk; absence of the posterior lobe in 9 cases; bright spot corresponding to an ectopic posterior lobe in 8 cases. These findings are similar to those already reported in pituitary dwarfism and may help understanding of the pathogenesis of the disease, which seems to be related to a pituitary stalk lesion. (orig.)

  17. Chest magnetic resonance imaging: a protocol suggestion

    Directory of Open Access Journals (Sweden)

    Bruno Hochhegger

    2015-12-01

    Full Text Available Abstract In the recent years, with the development of ultrafast sequences, magnetic resonance imaging (MRI has been established as a valuable diagnostic modality in body imaging. Because of improvements in speed and image quality, MRI is now ready for routine clinical use also in the study of pulmonary diseases. The main advantage of MRI of the lungs is its unique combination of morphological and functional assessment in a single imaging session. In this article, the authors review most technical aspects and suggest a protocol for performing chest MRI. The authors also describe the three major clinical indications for MRI of the lungs: staging of lung tumors; evaluation of pulmonary vascular diseases; and investigation of pulmonary abnormalities in patients who should not be exposed to radiation.

  18. Chest magnetic resonance imaging: a protocol suggestion*

    Science.gov (United States)

    Hochhegger, Bruno; de Souza, Vinícius Valério Silveira; Marchiori, Edson; Irion, Klaus Loureiro; Souza Jr., Arthur Soares; Elias Junior, Jorge; Rodrigues, Rosana Souza; Barreto, Miriam Menna; Escuissato, Dante Luiz; Mançano, Alexandre Dias; Araujo Neto, César Augusto; Guimarães, Marcos Duarte; Nin, Carlos Schuler; Santos, Marcel Koenigkam; Silva, Jorge Luiz Pereira e

    2015-01-01

    In the recent years, with the development of ultrafast sequences, magnetic resonance imaging (MRI) has been established as a valuable diagnostic modality in body imaging. Because of improvements in speed and image quality, MRI is now ready for routine clinical use also in the study of pulmonary diseases. The main advantage of MRI of the lungs is its unique combination of morphological and functional assessment in a single imaging session. In this article, the authors review most technical aspects and suggest a protocol for performing chest MRI. The authors also describe the three major clinical indications for MRI of the lungs: staging of lung tumors; evaluation of pulmonary vascular diseases; and investigation of pulmonary abnormalities in patients who should not be exposed to radiation. PMID:26811555

  19. Cardiac magnetic resonance imaging: patient safety considerations.

    Science.gov (United States)

    Giroletti, Elio; Corbucci, Giorgio

    Magnetic Resonance Imaging (MRI) is widely used in medicine. In cardiology, it is used to assess congenital or acquired diseases of the heat: and large vessels. Unless proper precautions are taken, it is generally advisable to avoid using this technique in patients with implanted electronic stimulators, such as pacemakers and defibrillators, on account of the potential risk of inducing electrical currents on the endocardial catheters, since these currents might stimulate the heart at a high frequency, thereby triggering dangerous arrhythmias. In addition to providing some basic information on pacemakers, defibrillators and MRI, and on the possible physical phenomena that may produce harmful effects, the present review examines the indications given in the literature, with particular reference to coronary stents, artificial heart valves and implantable cardiac stimulators.

  20. [Gastric magnetic resonance study (methods, semiotics)].

    Science.gov (United States)

    Stashuk, G A

    2003-01-01

    The paper shows the potentialities of gastric study by magnetic resonance imaging (MRI). The methodic aspects of gastric study have been worked out. The MRI-semiotics of the unchanged and tumor-affected wall of the stomach and techniques in examining patients with gastric cancer of various sites are described. Using the developed procedure, MRI was performed in 199 patients, including 154 patients with gastric pathology and 45 control individuals who had no altered gastric wall. Great emphasis is placed on the role of MRI in the diagnosis of endophytic (diffuse) gastric cancer that is of priority value in its morphological structure. MRI was found to play a role in the diagnosis of the spread of a tumorous process both along the walls of the stomach and to its adjacent anatomic structures.

  1. Magnetic resonance imaging of the small bowel

    Energy Technology Data Exchange (ETDEWEB)

    Deeab, Dhafer A., E-mail: dhafer_ahmed@yahoo.co [Department of Radiology, St Mary' s Campus, Imperial College NHS Trust, London (United Kingdom); Dick, Elizabeth; Sergot, Antoni A.; Sundblon, Lauren; Gedroyc, Wady [Department of Radiology, St Mary' s Campus, Imperial College NHS Trust, London (United Kingdom)

    2011-02-15

    Magnetic Resonance Imaging of the Small Bowel (MR Enterography, or MRE) is becoming increasingly popular as the first imaging modality for the diagnosis and follow-up of small bowel diseases. The inherent advantages of MRI, including excellent soft tissue contrast, multiplanar capability and lack of ionising radiation are well known. In addition, the use of luminal contrast agents in MRE has the added advantage of demonstrating the lumen and the wall directly, something not possible to achieve with conventional small bowel barium follow-through imaging. This review will highlight recent technical advances to this low cost, simple technique which is easily achievable in all hospitals. It will also review normal and abnormal radiological findings and highlight the value of this technique to both the clinician and patient alike in the investigation of small bowel disease.

  2. Magnetic resonance imaging of the adrenal

    Energy Technology Data Exchange (ETDEWEB)

    Reinig, J.W.; Doppmann, J.L.

    1986-04-01

    Magnetic resonance imaging (MRI) of the adrenals was performed on 50 subjects: 5 normal volunteers, 6 Cushing patients with bilateral adrenal hyperplasia, 14 patients with adrenal adenomas, 3 with adrenal carcinomas, 15 with pheochromocytomas and 7 with metastatic disease to the adrenal. The normal and hyperplastic adrenal glands were imaged in all cases. Using the signal intensity of the adrenals on a T2 weighted image, various forms of adrenal pathology could be differentiated. A ratio of signal intensity of the adrenal mass to the liver was utilized and allowed the differentitaion of adrenal adenomas from adrenal carcinomas, pheochromocytomas and metastases. Using the same ratio, metastases could be distinguished from pheochromocytomas as well. MRI appears to be particularly valuable in distinguishing clinically silent adrenal metastases from nonfunctioning adrenal adenomas.

  3. Functional magnetic resonance imaging studies of language.

    Science.gov (United States)

    Small, Steven L; Burton, Martha W

    2002-11-01

    Functional neuroimaging of language builds on almost 150 years of study in neurology, psychology, linguistics, anatomy, and physiology. In recent years, there has been an explosion of research using functional imaging technology, especially positron emission tomography (PET) and functional magnetic resonance imaging (fMRI), to understand the relationship between brain mechanisms and language processing. These methods combine high-resolution anatomic images with measures of language-specific brain activity to reveal neural correlates of language processing. This article reviews some of what has been learned about the neuroanatomy of language from these imaging techniques. We first discuss the normal case, organizing the presentation according to the levels of language, encompassing words (lexicon), sound structure (phonemes), and sentences (syntax and semantics). Next, we delve into some unusual language processing circumstances, including second languages and sign languages. Finally, we discuss abnormal language processing, including developmental and acquired dyslexia and aphasia.

  4. Fetal Cerebral Magnetic Resonance Imaging Beyond Morphology.

    Science.gov (United States)

    Jakab, András; Pogledic, Ivana; Schwartz, Ernst; Gruber, Gerlinde; Mitter, Christian; Brugger, Peter C; Langs, Georg; Schöpf, Veronika; Kasprian, Gregor; Prayer, Daniela

    2015-12-01

    The recent technological advancement of fast magnetic resonance imaging (MRI) sequences allowed the inclusion of diffusion tensor imaging, functional MRI, and proton MR spectroscopy in prenatal imaging protocols. These methods provide information beyond morphology and hold the key to improving several fields of human neuroscience and clinical diagnostics. Our review introduces the fundamental works that enabled these imaging techniques, and also highlights the most recent contributions to this emerging field of prenatal diagnostics, such as the structural and functional connectomic approach. We introduce the advanced image processing approaches that are extensively used to tackle fetal or maternal movement-related image artifacts, and which are necessary for the optimal interpretation of such imaging data. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Magnetic resonance imaging of facial muscles

    Energy Technology Data Exchange (ETDEWEB)

    Farrugia, M.E. [Department of Clinical Neurology, University of Oxford, Radcliffe Infirmary, Oxford (United Kingdom)], E-mail: m.e.farrugia@doctors.org.uk; Bydder, G.M. [Department of Radiology, University of California, San Diego, CA 92103-8226 (United States); Francis, J.M.; Robson, M.D. [OCMR, Department of Cardiovascular Medicine, University of Oxford, John Radcliffe Hospital, Oxford (United Kingdom)

    2007-11-15

    Facial and tongue muscles are commonly involved in patients with neuromuscular disorders. However, these muscles are not as easily accessible for biopsy and pathological examination as limb muscles. We have previously investigated myasthenia gravis patients with MuSK antibodies for facial and tongue muscle atrophy using different magnetic resonance imaging sequences, including ultrashort echo time techniques and image analysis tools that allowed us to obtain quantitative assessments of facial muscles. This imaging study had shown that facial muscle measurement is possible and that useful information can be obtained using a quantitative approach. In this paper we aim to review in detail the methods that we applied to our study, to enable clinicians to study these muscles within the domain of neuromuscular disease, oncological or head and neck specialties. Quantitative assessment of the facial musculature may be of value in improving the understanding of pathological processes occurring within facial muscles in certain neuromuscular disorders.

  6. Breast conserving therapy and magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Seki, Tsuneaki; Masuda, Yu; Hachiya, Junichi; Nitatori, Toshiaki; Fukushima, Hisayoshi; Uchigasaki, Shinya [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine

    1996-12-01

    Recently, breast conserving therapy has been widely accepted in our country. The extensive intraductal component (EIC) is a serious problem in breast conserving therapy, because it is well-known that EIC frequently causes locoregional recurrence in preserved breast parenchyma. Magnetic resonance imaging (MRI) is a useful method for detecting breast masses due to its excellent contrast resolution. We studied the application of MRI to detection of intraductal spread in twenty-two patients. All cases were revealed invasive cancer with intraductal spread by histopathological examination. MRI findings of intraductal spread can be divided into two major groups. One is daugter nodules or strand-like enhancement and the other is bridging enhancement. We also reffered to the preliminary study of MR-guiding transcutaneous aspiration biopsy of mammographically and clinically occult breast masses. (author)

  7. Quantum information processing through nuclear magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Bulnes, J.D.; Sarthour, R.S.; Oliveira, I.S. [Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil); Bonk, F.A.; Azevedo, E.R. de; Bonagamba, T.J. [Sao Paulo Univ., Sao Carlos, SP (Brazil). Inst. de Fisica; Freitas, J.C.C. [Espirito Santo Univ., Vitoria, ES (Brazil). Dept. de Fisica

    2005-09-15

    We discuss the applications of Nuclear Magnetic Resonance (NMR) to quantum information processing, focusing on the use of quadrupole nuclei for quantum computing. Various examples of experimental implementation of logic gates are given and compared to calculated NMR spectra and their respective density matrices. The technique of Quantum State Tomography for quadrupole nuclei is briefly described, and examples of measured density matrices in a two-qubit I = 3/2 spin system are shown. Experimental results of density matrices representing pseudo-Bell states are given, and an analysis of the entropy of theses states is made. Considering an NMR experiment as a depolarization quantum channel we calculate the entanglement fidelity and discuss the criteria for entanglement in liquid state NMR quantum information. A brief discussion on the perspectives for NMR quantum computing is presented at the end. (author)

  8. Magnetic resonance urography by virtual reality modelling.

    Science.gov (United States)

    Beigi, Navid; Sangild, Thomas; Terkildsen, Søren Vorre; Deding, Dorthe; Stødkilde-Jørgensen, Hans; Pedersen, Michael

    2003-01-01

    The purpose of this study was to create a 3D visualization of the urinary tract by a novel virtual reality approach, and to evaluate the usefulness of this method for papillary classification as compared with 2D urogram obtained by maximum intensity projection (MIP). In one healthy pig, magnetic resonance urography was performed using a T1-weighted 3D gradient echo pulse sequence. Post-processing was performed by means of an MIP algorithm and by using 3D virtual reality modelling, followed by manual classification of papillae as being either simple or compound. The 2D MIP urogram demonstrated 6 simple and 6 compound papillae, whereas the 3D urogram demonstrated 5 simple and 7 compound papillae. In both urograms, some papillae were unsuccessfully classified. The possibility of using virtual reality devices allowed 3D rotation and offered additional diagnostic information. However, further studies should reveal its feasibility in diseased kidneys.

  9. Stafne bone cavity--magnetic resonance imaging.

    Science.gov (United States)

    Segev, Yoram; Puterman, Max; Bodner, Lipa

    2006-07-01

    A case of Stafne bone cavity (SBC) affecting the body of the mandible of a 51-year-old female is reported. The imaging modalities included panoramic radiograph, computed tomography (CT) and magnetic resonance (MR) imaging. Panoramic radiograph and CT were able to determine the outline of the cavity and its three dimensional shape, but failed to precisely diagnose the soft tissue content of the cavity. MR imaging demonstrated that the bony cavity is filled with soft tissue that is continuous and identical in signal with that of the submandibular salivary gland. Based on the MR imaging a diagnosis of SBC was made and no further studies or surgical treatment were initiated. MR imaging should be considered the diagnostic technique in cases where SBC is suspected. Recognition of the lesion should preclude any further treatment or surgical exploration.

  10. Magnetic resonance imaging of optic nerve

    Directory of Open Access Journals (Sweden)

    Foram Gala

    2015-01-01

    Full Text Available Optic nerves are the second pair of cranial nerves and are unique as they represent an extension of the central nervous system. Apart from clinical and ophthalmoscopic evaluation, imaging, especially magnetic resonance imaging (MRI, plays an important role in the complete evaluation of optic nerve and the entire visual pathway. In this pictorial essay, the authors describe segmental anatomy of the optic nerve and review the imaging findings of various conditions affecting the optic nerves. MRI allows excellent depiction of the intricate anatomy of optic nerves due to its excellent soft tissue contrast without exposure to ionizing radiation, better delineation of the entire visual pathway, and accurate evaluation of associated intracranial pathologies.

  11. Magnetic resonance imaging of intervertebral disc degeneration

    Energy Technology Data Exchange (ETDEWEB)

    Maeda, Hiroshi; Noguchi, Masao (Kitakyushu City Yahata Hospital, Fukuoka (Japan)); Kira, Hideaki; Fujiki, Hiroshi; Shimokawa, Isao; Hinoue, Kaichi

    1993-02-01

    The aim of this study was to correlate the degree of lumbar intervertebral disc degeneration with findings of magnetic resonance imaging (MRI). Seventeen autopsied (from 7 patients) and 21 surgical (from 20 patients) intervertebral discs were used as specimens for histopathological examination. In addition, 21 intervertebral discs were examined on T2-weighted images. Histopathological findings from both autopsied and surgical specimens were well correlated with MRI findings. In particular, T2-weighted images reflected increased collagen fibers and rupture within the fibrous ring accurately. However, when severely degenerated intervertebral discs and hernia protruding the posterior longitudinal ligament existed, histological findings were not concordant well with T2-weighted images. Morphological appearances of autopsy specimens, divided into four on T2-weighted images, were well consistent with histological degeneration. This morphological classification, as shown on T2-weighted images, could also be used in the evaluation of intervertebral disc degeneration. (N.K.).

  12. Magnetic resonance imaging of brain death

    Energy Technology Data Exchange (ETDEWEB)

    Lee, D.H.; Nathanson, J.A.; Fox, A.J.; Pelz, D.M.; Lownie, S.P.

    1995-06-01

    In order to demonstrate the magnetic resonance imaging (MRI) appearance of the brain in patients with clinical brain death, high-field MRI was performed on 5 patients using conventional T1-weighted and T2-weighted imaging. The study showed MRI exhibited similar features for all of the patients, features which were not found in MRI of comatose patients who were not clinically brain dead. It was stated that up to now the most important limitation in MRI of patients with suspected brain death has been the extreme difficulty of moving them out of the intensive care setting. If this problem can be overcome, and it appears possible with with the advent of MRI-compatible ventilators and noninvasive monitoring, MRI could become an excellent alternative for confirming clinical diagnosis of brain death for such patients. 15 refs., 3 figs.

  13. Quantum information processing and nuclear magnetic resonance

    CERN Document Server

    Cummins, H K

    2001-01-01

    as spectrometer pulse sequence programs. Quantum computers are information processing devices which operate by and exploit the laws of quantum mechanics, potentially allowing them to solve problems which are intractable using classical computers. This dissertation considers the practical issues involved in one of the more successful implementations to date, nuclear magnetic resonance (NMR). Techniques for dealing with systematic errors are presented, and a quantum protocol is implemented. Chapter 1 is a brief introduction to quantum computation. The physical basis of its efficiency and issues involved in its implementation are discussed. NMR quantum information processing is reviewed in more detail in Chapter 2. Chapter 3 considers some of the errors that may be introduced in the process of implementing an algorithm, and high-level ways of reducing the impact of these errors by using composite rotations. Novel general expressions for stabilising composite rotations are presented in Chapter 4 and a new class o...

  14. Magnetic resonance imaging of traumatic cervical injury

    Energy Technology Data Exchange (ETDEWEB)

    Juhng, S. K.; Lee, K. S.; Sohn, K. J.; Choi, S. S.; Won, J. J. [Wonkwang University School of Medicine, Iri (Korea, Republic of)

    1994-04-15

    To evaluate magnetic resonance imaging (MRI) findings of cevical injuries. MRI studies of 34 patients with cervical spinal injuries were analyzed retrospectively. All MRI scans were obtained with an 1.0T superconductive MRI scanner (Siemens Magnetom 42SPE) and their findings were analyzed regarding the spinal cord, bony spine, ligaments, and intervertebral disks. A variety of abnormal findings were detected: 25 cord abnormalities including cord compression (15 cases), cord edema (4 cases), syringomyelia (4 cases), myelomalacia (1 case), and hemorrhagic contusion (1 case), 18 ligamentous injuries, 22 disk herniations (9 post-traumatic, 13 chronic degenerative), 11 spine fractures, and 4 subluxations. MRI is useful in evaluating the spinal cord itself, in depicting ligamentous injuries, in establishing the presence of disc herniation, and in assessing the alignment of cervical spine.

  15. Nuclear magnetic resonance imaging of the spine

    Energy Technology Data Exchange (ETDEWEB)

    Modic, M.T.; Weinstein, M.A.; Pavlicek, W.; Starnes, D.L.; Duchesneau, P.M.; Boumphrey, F.; Hardy, R.J. Jr.

    1984-01-01

    Forty subjects were examined to determine the accuracy and clinical usefulness of nuclear magnetic resonance (NMR) examination of the spine. The NMR images were compared with plain radiographs, high-resolution computed tomograms, and myelograms. The study included 15 patients with normal spinal cord anatomy and 25 patients whose pathological conditions included canal stenosis, herniated discs, metastatic tumors, primary cord tumor, trauma, Chiari malformations, syringomyelia, and developmental disorders. Saturation recovery images were best in differentiating between soft tissue and cerebrospinal fluid. NMR was excellent for the evaluation of the foramen magnum region and is presently the modality of choice for the diagnosis of syringomyelia and Chiari malformation. NMR was accurate in diagnosing spinal cord trauma and spinal canal block.

  16. Cardiovascular magnetic resonance in hypertrophic cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Shiozaki, Afonso Akio; Parga, Jose Rodrigues; Arteaga, Edmundo; Rochitte, Carlos Eduardo [Sao Paulo Univ. (USP), SP (Brazil). Instituto do Coracao. Setor de Tomografia Computarizada e Ressonancia Magnetica Cardiovascular]. E-mail: rochitte@incor.usp.br; Kim, Raymond J. [Duke Cardiovascular Magnetic Resonance Center, Durham, NC (United States); Tassi, Eduardo Marinho [Diagnosticos da America S.A., Rio de Janeiro, RJ (Brazil). Sector of Cardiovascular Magnetic Resonance and Computed Tomography

    2007-03-15

    Hypertrophic cardiomyopathy (HCM) is the most frequent genetic cardiac disease that causes sudden death in young people, with an incidence of 1:500 adults. The routinely used criteria for worst prognosis have limited sensitivity and specificity. Thus, the estimated risk of evolving to dilated cardiomyopathy or sudden death is somewhat inaccurate, leading to management uncertainty of HCM patients. Therefore, an accurate noninvasive method for the diagnosis of HCM with prognostic value is of great importance. In the last years, Cardiovascular Magnetic Resonance (CMR) emerged not only as a diagnostic tool, but also as a study with prognostic values, by characterizing myocardial fibrosis with great accuracy in HCM patients. Additionally, CMR identifies the types of hypertrophy, analyses the ventricular function, estimates the intraventricular gradient and allows the determination of differential diagnosis. Moreover, CMR can uniquely access myocardial fibrosis in HCM. (author)

  17. Prostate magnetic resonance imaging: challenges of implementation.

    Science.gov (United States)

    Loch, Ronald; Fowler, Kathryn; Schmidt, Ryan; Ippolito, Joseph; Siegel, Cary; Narra, Vamsi

    2015-01-01

    Prostate cancer is among the most common causes of cancer and cancer deaths in men. Screening methods and optimal treatments have become controversial in recent years. Prostate magnetic resonance imaging (MRI) is gaining popularity as a tool to assist diagnosis, risk assessment, and staging. However, implementation into clinical practice can be difficult, with many challenges associated with image acquisition, postprocessing, interpretation, reporting, and radiologic-pathologic correlation. Although state-of-the-art technology is available at select sites for targeting tissue biopsy and interpreting multiparametric prostate MRI, many institutions struggle with adapting this new technology into an efficient multidisciplinary model of patient care. This article reviews several of the challenges that radiologists should be aware of when integrating prostate MRI into their clinical practice.

  18. Magnetic resonance imaging of septic sacroiliitis

    Energy Technology Data Exchange (ETDEWEB)

    Sandrasegaran, K. (MRI Unit, Dept. of Radiology, St. James' s Univ. Hospital, Leeds (United Kingdom)); Saifuddin, A. (MRI Unit, Dept. of Radiology, St. James' s Univ. Hospital, Leeds (United Kingdom)); Coral, A. (MRI Unit, Dept. of Radiology, St. James' s Univ. Hospital, Leeds (United Kingdom)); Butt, W.P. (MRI Unit, Dept. of Radiology, St. James' s Univ. Hospital, Leeds (United Kingdom))

    1994-05-01

    Five cases of septic sacroiliitis diagnosed by magnetic resonance imaging (MRI) are presented. Imaging was performed between 2 and 14 days after onset of symptoms and consisted of varying combinations of coronal short tau inversion recovery (STIR), axial T2-weighted spin echo (SE), and coronal and axial pre- and postcontrast T1-weighted SE scans. Abnormalities included demonstration of sacroiliac joint effusions, bone oedema and adjacent inflammation as high signal on STIR and T2-weighted SE scans, and identification of abscesses in two cases as rim-enhancing lesions anterior to the joint on gadolinium-enhanced T1-weighted SE scans. The role of MRI and other forms of imaging in septic sacroiliitis is discussed. (orig.)

  19. Monitoring angiogenesis using magnetic resonance methods

    DEFF Research Database (Denmark)

    Holm, David Alberg

    2008-01-01

    -angiogenic treatment is presented in the first manuscript. In the second and third manuscript, two separate methods of quantifying perfusion, blood volume and vessel permeability are presented. The methods are used to show that drug delivery to a xenografted tumor is plausible and to show possible vascular maturation...... and the involved signaling molecules. Subsequently, a short review of contrast agents and perfusion measurements is given. Finally, methods for monitoring angiogenesis using magnetic resonance imaging are reviewed. A method for monitoring early stages of angiogenesis as well as the effect of anti...... in a transgenic mouse model. The last manuscript presents a new method for in vivo cell labeling. This method could find use in studying the metastatic spread of cancer cells throughout the body....

  20. Cardiovascular magnetic resonance in carotid atherosclerotic disease

    Directory of Open Access Journals (Sweden)

    Chen Huijun

    2009-12-01

    Full Text Available Abstract Atherosclerosis is a chronic, progressive, inflammatory disease affecting many vascular beds. Disease progression leads to acute cardiovascular events such as myocardial infarction, stroke and death. The diseased carotid alone is responsible for one third of the 700,000 new or recurrent strokes occurring yearly in the United States. Imaging plays an important role in the management of atherosclerosis, and cardiovascular magnetic resonance (CMR of the carotid vessel wall is one promising modality in the evaluation of patients with carotid atherosclerotic disease. Advances in carotid vessel wall CMR allow comprehensive assessment of morphology inside the wall, contributing substantial disease-specific information beyond luminal stenosis. Although carotid vessel wall CMR has not been widely used to screen for carotid atherosclerotic disease, many trials support its potential for this indication. This review summarizes the current state of knowledge regarding carotid vessel wall CMR and its potential clinical application for management of carotid atherosclerotic disease.

  1. Optimal sequence for magnetic resonance cholangiopancreatography

    Energy Technology Data Exchange (ETDEWEB)

    Kanzaki, Hiroshi; Akata, Soichi; Ozuki, Taizo; Abe, Kimihiko [Tokyo Medical Coll. (Japan)

    2001-09-01

    Magnetic resonance cholangiopancreatography (MRCP) has attracted attention as a useful examination for abnormalities of the pancreaticobiliary system, because it is a simple procedure. Since there are few detailed reports on optimal sequences for MRCP, we attempted to clarify the topic. The magnetic resonance imaging (MRI) equipment we used was a 1.0 Tesla super-conductive type. A fast spin echo (16 echo train) was used, and the echo space was set at 17 msec. TE was changed from 17 msec to 272 msec in 17 msec increments. TR was changed from 1,000 msec to 9,000 msec by 1,000 msec increments. Bile juice which had been collected from the PTCD tube of a patient with common bile duct cancer, was put in a test tube of 10 mm internal diameter. Saline was used as a substitute for pancreatic juice, because collection of pancreatic juice was difficult. Fat was used for contrast. Each signal intensity inside the test tube was measured and evaluated. We attempted to evaluate the signal of gastric juice by adding blueberry juice, making use of its manganese ion (Mn{sup ++}). With longer TR, the signal intensities of bile and pancreas juice increased. As TE became longer, the signal intensities of bile and pancreas juice decreased slightly, while that of fat decreased much more. In MRCP, it is necessary to set up a long TE to increase the relative signal intensity difference of fat in bile and pancreas juice. The signal intensity of gastric juice was made to disappear by the addition of blueberry juice diluted to a ratio of 1:3. (author)

  2. Observation of spin diffusion in zero-field magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Suter, D.; Jarvie, T.P.; Sun, B.; Pines, A.

    1987-07-06

    We report the measurement of spin diffusion at zero field, observed by two-dimensional deuterium magnetic resonance of a polycrystalline sample. This demonstrates for the first time an appealing feature of pulsed zero-field magnetic resonance, namely the potential for structure determination in solids without the need for single crystals or oriented samples.

  3. Resonances and dipole moments in dielectric, magnetic, and magnetodielectric cylinders

    DEFF Research Database (Denmark)

    Dirksen, A.; Arslanagic, Samel; Breinbjerg, Olav

    2011-01-01

    An eigenfunction solution to the problem of plane wave scattering by dielectric, magnetic, and magnetodielectric cylinders is used for a systematic investigation of their resonances. An overview of the resonances with electric and magnetic dipole moments, needed in, e.g., the synthesis...... of metamaterials, is given with an emphasis on their strength, bandwidth, and isolation....

  4. Monitoring Locally Induced Hyperthermia with Magnetic Resonance Imaging

    NARCIS (Netherlands)

    M.W. Vogel (M.)

    2005-01-01

    markdownabstract__Abstract__ Magnetic resonance thermometry is a relatively new and unique technology for non-invasive monitoring of (local) therapeutic temperature changes that is not yet in common use. Temperature measurements using magnetic resonance heat thermometry can be performed in several

  5. Computed tomography and magnetic resonance findings in lipoid pneumonia.

    OpenAIRE

    Bréchot, J M; Buy, J.N.; Laaban, J P; Rochemaure, J

    1991-01-01

    A case of exogenous lipoid pneumonia was documented by computed tomography and magnetic resonance imaging. Although strongly suggesting the presence of fat on T1 weighted images, magnetic resonance does not produce images specific for this condition. Computed tomography is the best imaging modality for its diagnosis.

  6. Nuclear magnetic resonance in environmental engineering: principles and applications.

    NARCIS (Netherlands)

    Lens, P.N.L.; Hemminga, M.A.

    1998-01-01

    This paper gives an introduction to nuclear magnetic resonance spectroscopy (NMR) and magnetic resonance imaging (MRI) in relation to applications in the field of environmental science and engineering. The underlying principles of high resolution solution and solid state NMR, relaxation time measure

  7. Compact electrically detected magnetic resonance setup

    Directory of Open Access Journals (Sweden)

    Michael Eckardt

    2015-04-01

    Full Text Available Electrically detected magnetic resonance (EDMR is a commonly used technique for the study of spin-dependent transport processes in semiconductor materials and electro-optical devices. Here, we present the design and implementation of a compact setup to measure EDMR, which is based on a commercially available benchtop electron paramagnetic resonance (EPR spectrometer. The electrical detection part uses mostly off-the-shelf electrical components and is thus highly customizable. We present a characterization and calibration procedure for the instrument that allowed us to quantitatively reproduce results obtained on a silicon-based reference sample with a “large-scale” state-of-the-art instrument. This shows that EDMR can be used in novel contexts relevant for semiconductor device fabrication like clean room environments and even glove boxes. As an application example, we present data on a class of environment-sensitive objects new to EDMR, semiconducting organic microcrystals, and discuss similarities and differences to data obtained for thin-film devices of the same molecule.

  8. Mathematical Development and Computational Analysis of Harmonic Phase-Magnetic Resonance Imaging (HARP-MRI) Based on Bloch Nuclear Magnetic Resonance (NMR) Diffusion Model for Myocardial Motion.

    Science.gov (United States)

    Dada, Michael O; Jayeoba, Babatunde; Awojoyogbe, Bamidele O; Uno, Uno E; Awe, Oluseyi E

    2017-09-13

    Harmonic Phase-Magnetic Resonance Imaging (HARP-MRI) is a tagged image analysis method that can measure myocardial motion and strain in near real-time and is considered a potential candidate to make magnetic resonance tagging clinically viable. However, analytical expressions of radially tagged transverse magnetization in polar coordinates (which is required to appropriately describe the shape of the heart) have not been explored because the physics required to directly connect myocardial deformation of tagged Nuclear Magnetic Resonance (NMR) transverse magnetization in polar geometry and the appropriate harmonic phase parameters are not yet available. The analytical solution of Bloch NMR diffusion equation in spherical geometry with appropriate spherical wave tagging function is important for proper analysis and monitoring of heart systolic and diastolic deformation with relevant boundary conditions. In this study, we applied Harmonic Phase MRI method to compute the difference between tagged and untagged NMR transverse magnetization based on the Bloch NMR diffusion equation and obtained radial wave tagging function for analysis of myocardial motion. The analytical solution of the Bloch NMR equations and the computational simulation of myocardial motion as developed in this study are intended to significantly improve healthcare for accurate diagnosis, prognosis and treatment of cardiovascular related deceases at the lowest cost because MRI scan is still one of the most expensive anywhere. The analysis is fundamental and significant because all Magnetic Resonance Imaging techniques are based on the Bloch NMR flow equations.

  9. Magnetic resonance spectroscopy as a diagnostic modality for carcinoma thyroid

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Nikhil [Department of Surgery, Maulana Azad Medical College, Lok Nayak Hospital, New Delhi (India)], E-mail: nikhil_ms26@yahoo.co.in; Kakar, Arun K. [Department of Surgery, Maulana Azad Medical College, Lok Nayak Hospital, New Delhi (India); Chowdhury, Veena [Department of Radiodiagnosis, Maulana Azad Medical College, Lok Nayak Hospital, New Delhi (India); Gulati, Praveen [MR Centre, A-23 Green Park, New Delhi (India); Shankar, L. Ravi [Department of Radioiodine Uptake and Imaging, Institute of Nucler Medicine and Allied Sciences (INMAS), Timarpur, New Delhi (India); Vindal, Anubhav [Department of Surgery, Maulana Azad Medical College, Lok Nayak Hospital, New Delhi (India)

    2007-12-15

    Aim: The aim of this study was to observe the findings of magnetic resonance spectroscopy of solitary thyroid nodules and its correlation with histopathology. Materials and methods: In this study, magnetic resonance spectroscopy was carried out on 26 patients having solitary thyroid nodules. Magnetic resonance spectroscopy (MRS) was performed on a 1.5 T super conductive system with gradient strength of 33 mTs. Fine needle aspiration cytology was done after MRS. All 26 patients underwent surgery either because of cytopathologically proven malignancy or because of cosmetic reasons. Findings of magnetic resonance spectroscopy were compared with histopathology of thyroid specimens. Results and conclusion: It was seen that presence or absence of choline peak correlates very well with presence or absence of malignant foci with in the nodule (sensitivity = 100%; specificity = 88.88%). These results indicate that magnetic resonance spectroscopy may prove to be an useful diagnostic modality for carcinoma thyroid.

  10. Torque-mixing magnetic resonance spectroscopy (Conference Presentation)

    Science.gov (United States)

    Losby, Joseph; Fani Sani, Fatemeh; Grandmont, Dylan T.; Diao, Zhu; Belov, Miro; Burgess, Jacob A.; Compton, Shawn R.; Hiebert, Wayne K.; Vick, Doug; Mohammad, Kaveh; Salimi, Elham; Bridges, Gregory E.; Thomson, Douglas J.; Freeman, Mark R.

    2016-10-01

    An optomechanical platform for magnetic resonance spectroscopy will be presented. The method relies on frequency mixing of orthogonal RF fields to yield a torque amplitude (arising from the transverse component of a precessing dipole moment, in analogy to magnetic resonance detection by electromagnetic induction) on a miniaturized resonant mechanical torsion sensor. In contrast to induction, the method is fully broadband and allows for simultaneous observation of the equilibrium net magnetic moment alongside the associated magnetization dynamics. To illustrate the method, comprehensive electron spin resonance spectra of a mesoscopic, single-crystal YIG disk at room temperature will be presented, along with situations where torque spectroscopy can offer complimentary information to existing magnetic resonance detection techniques. The authors are very grateful for support from NSERC, CRC, AITF, and NINT. Reference: Science 350, 798 (2015).

  11. Italian registry of cardiac magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Francone, Marco [Department of Radiological, Oncological and Pathological Sciences, Sapienza University of Rome (Italy); Di Cesare, Ernesto, E-mail: ernesto.dicesare@cc.univaq.it [Dipartimento di Scienze Cliniche Applicate e Biotecnologie, Università di L’Aquila (Italy); Cademartiri, Filippo [Cardio-Vascular Imaging Unit, Giovanni XXIII Hospital, Monastier di Treviso, TV (Italy); Erasmus Medical Center University, Rotterdam (Netherlands); Pontone, Gianluca [IRCCS Centro Cardiologico Monzino (Italy); Lovato, Luigi [Policlinico S. Orsola Bologna (Italy); Matta, Gildo [Azienda ospedaliera G Brotzu Cagliari (Italy); Secchi, Francesco [IRCCS Policlinico San Donato, Radiology Unit, Milan (Italy); Maffei, Erica [Cardio-Vascular Imaging Unit, Giovanni XXIII Hospital, Monastier di Treviso, TV (Italy); Erasmus Medical Center University, Rotterdam (Netherlands); Pradella, Silvia [Azienda Ospedaliera Universitaria Careggi (Italy); Carbone, Iacopo [Department of Radiological, Oncological and Pathological Sciences, Sapienza University of Rome (Italy); Marano, Riccardo [Policlinico Gemelli, Università Cattolica Roma (Italy); Bacigalupo, Lorenzo [Ospedale Galliera, Genova (Italy); Chiodi, Elisabetta [Ospedale S. Anna Ferrara (Italy); Donato, Rocco [Azienda Ospedaliera Universitaria G. Martino, Me (Italy); Sbarbati, Stefano [Ospedale Madre Giuseppina Vannini, Roma (Italy); De Cobelli, Francesco [IRCCS S. Raffaele, Università Vita Salute, Milano (Italy); Di Renzi, Paolo [Fate Bene Fratelli Isola tiberina, Roma (Italy); Ligabue, Guido; Mancini, Andrea [Azienda Ospedaliera-Universitaria Policlinico di Modena (Italy); Palmieri, Francesco [Diparimento di Diagnostica per immagini e radiologia interventistica, Ospedale S. Maria delle Grazie, Pozzuoli, Napoli (Italy); and others

    2014-01-15

    Objectives: Forty sites were involved in this multicenter and multivendor registry, which sought to evaluate indications, spectrum of protocols, impact on clinical decision making and safety profile of cardiac magnetic resonance (CMR). Materials and methods: Data were prospectively collected on a 6-month period and included 3376 patients (47.2 ± 19 years; range 1–92 years). Recruited centers were asked to complete a preliminary general report followed by a single form/patient. Referral physicians were not required to exhibit any specific certificate of competency in CMR imaging. Results: Exams were performed with 1.5 T scanners in 96% of cases followed by 3 T (3%) and 1 T (1%) magnets and contrast was administered in 84% of cases. The majority of cases were performed for the workup of inflammatory heart disease/cardiomyopathies representing overall 55.7% of exams followed by the assessment of myocardial viability and acute infarction (respectively 6.9% and 5.9% of patients). In 49% of cases the final diagnosis provided was considered relevant and with impact on patient's clinical/therapeutic management. Safety evaluation revealed 30 (0.88%) clinical events, most of which due to patient's preexisting conditions. Radiological reporting was recorded in 73% of exams. Conclusions: CMR is performed in a large number of centers in Italy with relevant impact on clinical decision making and high safety profile.

  12. Experiments in Nuclear Magnetic Resonance Microscopy

    Science.gov (United States)

    Lee, Yong; Lu, Wei; Choi, J.-H.; Chia, H. J.; Mirsaidov, U. M.; Guchhait, S.; Cambou, A. D.; Cardenas, R.; Park, K.; Markert, J. T.

    2006-03-01

    We report our group's effort in the construction of an 8-T, ^3 He cryostat based nuclear magnetic resonance force microscope (NMRFM). The probe has two independent 3-D of piezoelectric x-y-z positioners for precise positioning of a fiber optic interferometer and a sample/gradient-producing magnet with respect to a micro-cantilever. The piezoelectric positioners have a very uniform controllable step size with virtually no backlash. A novel RF tuning circuit board design is implemented which allows us to simply swap out one RF component board with another for experiments involving different nuclear species. We successfully fabricated and are characterizing 50μm x50μm x0.2μm double torsional oscillators. We have also been characterizing ultrasoft cantilevers whose spring constant is on the order of 10-4 N/m. We also report NMRFM data for ammonium dihydrogen phosphate(ADP) at room temperature using our 1.2-T system. Observed features include the correct shift of the NMR peak with carrier frequency, increases in signal amplitude with both RF field strength and frequency modulation amplitude, and signal oscillation (spin nutation) as a function of tipping RF pulse length. Experiments in progress on NH4MgF3 (at 1.2 T) and MgB2 (at 8.1 T) will also be briefly reviewed. Robert A. Welch Foundation grant No.F-1191 and the National Science Foundation grant No. DMR-0210383.

  13. Electric and magnetic dipole couplings in split ring resonator metamaterials

    Institute of Scientific and Technical Information of China (English)

    Fan Jing; Sun Guang-Yong; and Zhu Wei-Ren

    2011-01-01

    In this paper,the electric and the magnetic dipole couplings between the outer and the inner rings of a single split ring resonator (SRR) are investigated.We numerically demonstrate that the magnetic resonance frequency can be substantially modified by changing the couplings of the electric and magnetic dipoles,and give a theoretical expression of the magnetic resonance frequency.The results in this work are expected to be conducive to a deeper understanding of the SRR and other similar metamaterials,and provide new guidance for complex metamaterials design with a tailored electromagnetic response.

  14. Magnetic resonance imaging in neurologic diseases

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Hyun; Han, Man Chung; Wan, Chu Wan; Myung, Ho Jin; Choi, Kil Soo [Seoul National University College of Medicine, Seoul (Korea, Republic of); Ahn, Chang Beom; Oh, Chang Hyun; Cho, Zang Hee [Koear Advanced Institute of Science, Seoul (Korea, Republic of)

    1985-02-15

    Magnetic resonance (MR) imaging with 0.15 Tesla resistive magnet developed by Korea Advanced Institute of Science were performed in 27 patients with various neurologic diseases and compared with x-ray computed tomography (CT). The purpose of the paper is to evaluate the image quality, the diagnostic value and limitation, and the optimal pulse sequence of MR imagings with a resistive magnet. The MR images were obtained by using a variety of pulse sequence with spin echo technique including saturation recovery. T2-weighted spin echo, and/or inversion recovery with various pulse repetition (TR) and echo delay (TE) times. The MR imaging demonstrated the capability of detecting the lesions shown on CT in al cases and also detected an additional finding in one case (multiple sclerosis) which was not seen on CT. The MR imaging appeared to be more useful than CT in the evaluation of syringomyelia of spinal cord and white matter disease, while it failed to demonstrated small calcific lesion or inflammatory nodule (less than 1 cm) shown on CT and has shown somewhat poor contrast resolution in the case of meingloma. The spatial resolution of saturation recovery images was similar or superior to CT, whereas the contrast resolution of saturation recovery was inferior to CT. While the saturation recovery images have shown false negative findings in 5 patients (19%), the inversion recovery and T2-weighted spin echo have shown consistently positive findings. The inversive recovery and T2-weighted spin echo images demonstrated better contrast discrimination between normal and pathologic conditions than the saturation recovery images, but somewhat poorer spatial resolution. Authors suggest that the MR images of both the saturation recovery with 300/30 and T2-weighted spin echo with 1000/90 be used as a routine procedure and additional inversion recovery of 1300/300/30 sequence as a option if white matter disease is suspected.

  15. Waveguide volume probe for magnetic resonance imaging and spectroscopy

    DEFF Research Database (Denmark)

    2015-01-01

    The present disclosure relates to a probe for use within the field of nuclear magnetic resonance, such as magnetic resonance imaging (MRI), and magnetic resonance spectroscopy (MRS)). One embodiment relates to an RF probe for magnetic resonance imaging and/or spectroscopy comprising a conductive...... non-magnetic hollow waveguide having an internal volume and at least one open end, one or more capacitors and at least a first conductive non-magnetic wire, wherein said first conductive wire connects at least one of said one or more capacitors to opposite walls of one open end of the waveguide...... and wherein said first conductive wire and said one or more capacitors are located outside of said internal volume, wherein the internal volume of the hollow waveguide defines an imaging volume or sample volume....

  16. Controlling interactions between highly magnetic atoms with Feshbach resonances.

    Science.gov (United States)

    Kotochigova, Svetlana

    2014-09-01

    This paper reviews current experimental and theoretical progress in the study of dipolar quantum gases of ground and meta-stable atoms with a large magnetic moment. We emphasize the anisotropic nature of Feshbach resonances due to coupling to fast-rotating resonant molecular states in ultracold s-wave collisions between magnetic atoms in external magnetic fields. The dramatic differences in the distribution of resonances of magnetic (7)S3 chromium and magnetic lanthanide atoms with a submerged 4f shell and non-zero electron angular momentum is analyzed. We focus on dysprosium and erbium as important experimental advances have been recently made to cool and create quantum-degenerate gases for these atoms. Finally, we describe progress in locating resonances in collisions of meta-stable magnetic atoms in electronic P-states with ground-state atoms, where an interplay between collisional anisotropies and spin-orbit coupling exists.

  17. Controlling interactions between highly-magnetic atoms with Feshbach resonances

    CERN Document Server

    Kotochigova, Svetlana

    2014-01-01

    This paper reviews current experimental and theoretical progress in the study of dipolar quantum gases of ground and meta-stable atoms with a large magnetic moment. We emphasize the anisotropic nature of Feshbach resonances due to coupling to fast-rotating resonant molecular states in ultracold s-wave collisions between magnetic atoms in external magnetic fields. The dramatic differences in the distribution of resonances of magnetic $^7$S$_3$ chromium and magnetic lanthanide atoms with a submerged 4f shell and non-zero electron angular momentum is analyzed. We focus on Dysprosium and Erbium as important experimental advances have been recently made to cool and create quantum-degenerate gases for these atoms. Finally, we describe progress in locating resonances in collisions of meta-stable magnetic atoms in electronic P states with ground-state atoms, where an interplay between collisional anisotropies and spin-orbit coupling exists.

  18. Evaluation of the flow of cerebrospinal fluid as well as gender and age characteristics in patients with communicating hydrocephalus, using phase-contrast magnetic resonance imaging.

    Science.gov (United States)

    Bogomyakova, Olga; Stankevich, Yu; Mesropyan, N; Shaybman, L; Tulupov, A

    2016-12-01

    To determine the difference in the velocity parameters of cerebrospinal fluid flow in patients with varying severity of communicating hydrocephalus compared to a group of healthy volunteers without hydrodynamic disorders. The study involved 35 subjects with communicating hydrocephalus (25 subjects with Evans index of 0.31; 10 subject with Evans index of 0.46) and 62 healthy volunteers. The mean, volume, and peak flow velocities were determined at the different intracranial levels. Also were made an assessment of gender and age differences. Analysis of the differences between the mean values showed the progressive inhibition of cerebrospinal fluid outflow from the cranial cavity [in moderate communicating hydrocephalus-at 1.5 times (p hydrocephalus at 2-2.5 times (p < 0.01)], depending on the severity of enlargement of the ventricular system and, most likely, related to inhibition of its reabsorption. These changes may explain the clinical symptoms of subjects and serve as diagnostic criteria. Also it was revealed a significant influence of the factor of age on speed characteristics of the cerebrospinal fluid flow (F = 5.3303, p = 0.0003, for mean velocity).

  19. Control of Transport-barrier relaxations by Resonant Magnetic Perturbations

    CERN Document Server

    Leconte, M; Garbet, X; Benkadda, S

    2009-01-01

    Transport-barrier relaxation oscillations in the presence of resonant magnetic perturbations are investigated using three-dimensional global fluid turbulence simulations from first principles at the edge of a tokamak. It is shown that resonant magnetic perturbations have a stabilizing effect on these relaxation oscillations and that this effect is due mainly to a modification of the pressure profile linked to the presence of both residual residual magnetic island chains and a stochastic layer.

  20. Normal ranges and test-retest reproducibility of flow and velocity parameters in intracranial arteries measured with phase-contrast magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Correia de Verdier, Maria; Wikstroem, Johan [Uppsala University Hospital, Department of Radiology, Uppsala University, Uppsala (Sweden)

    2016-05-15

    The purpose of the present study was to investigate normal ranges and test-retest reproducibility of phase-contrast MRI (PC-MRI)-measured flow and velocity parameters in intracranial arteries. Highest flow (HF), lowest flow (LF), peak systolic velocity (PSV), and end diastolic velocity (EDV) were measured at two dates in the anterior (ACA), middle (MCA), and posterior (PCA) cerebral arteries of 30 healthy volunteers using two-dimensional PC-MRI at 3 T. Least detectable difference (LDD) was calculated. In the left ACA, HF was (mean (range, LDD)) 126 ml/min (36-312, 59 %), LF 61 ml/min (0-156, 101 %), PSV 64 cm/s (32-141, 67 %), and EDV 35 cm/s (18-55, 42 %); in the right ACA, HF was 154 ml/min (42-246, 49 %), LF 77 ml/min (0-156, 131 %), PSV 75 cm/s (26-161, 82 %), and EDV 39 cm/s (7-59, 67 %). In the left MCA, HF was 235 ml/min (126-372, 35 %), LF 116 ml/min (42-186, 48 %), PSV 90 cm/s (55-183, 39 %), and EDV 46 cm/s (20-66, 28 %); in the right MCA, HF was 238 ml/min (162-342, 44 %), LF 120 ml/min (72-216, 48 %), PSV 88 cm/s (55-141, 35 %), and EDV 45 cm/s (26-67, 23 %). In the left PCA, HF was 108 ml/min (42-168, 54 %), LF 53 ml/min (18-108, 64 %), PSV 50 cm/s (24-77, 63 %), and EDV 28 cm/s (14-40, 45 %); in the right PCA, HF was 98 ml/min (30-162, 49 %), LF 49 ml/min (12-84, 55 %), PSV 47 cm/s (27-88, 59 %), and EDV 27 cm/s (16-41, 45 %). PC-MRI-measured flow and velocity parameters in the main intracranial arteries have large normal ranges. Reproducibility is highest in MCA. (orig.)

  1. Feasibility of measuring renal blood flow by phase-contrast magnetic resonance imaging in patients with autosomal dominant polycystic kidney disease

    Energy Technology Data Exchange (ETDEWEB)

    Spithoven, E.M.; Meijer, E.; Boertien, W.E.; Gaillard, C.A.J.M.; Jong, P.E. de; Gansevoort, R.T. [University of Groningen, Department of Nephrology, Community and Occupational Medicine, University Medical Center Groningen, PO Box 30.001, RB Groningen (Netherlands); Borns, C.; Kappert, P.; Greuter, M.J.W.; Jagt, E. van der [University of Groningen, Department of Radiology, Community and Occupational Medicine, University Medical Center Groningen, Groningen (Netherlands); Vart, P. [University of Groningen, Department of Health Sciences, Community and Occupational Medicine, University Medical Center Groningen, Groningen (Netherlands)

    2016-03-15

    Renal blood flow (RBF) has been shown to predict disease progression in autosomal dominant polycystic kidney disease (ADPKD). We investigated the feasibility and accuracy of phase-contrast RBF by MRI (RBF{sub MRI}) in ADPKD patients with a wide range of estimated glomerular filtration rate (eGFR) values. First, we validated RBF{sub MRI} measurement using phantoms simulating renal artery hemodynamics. Thereafter, we investigated in a test-set of 21 patients intra- and inter-observer coefficient of variation of RBF{sub MRI}. After validation, we measured RBF{sub MRI} in a cohort of 91 patients and compared the variability explained by characteristics indicative for disease severity for RBF{sub MRI} and RBF measured by continuous hippuran infusion. The correlation in flow measurement using phantoms by phase-contrast MRI was high and fluid collection was high (CCC=0.969). Technical problems that precluded RBF{sub MRI} measurement occurred predominantly in patients with a lower eGFR (34% vs. 16%). In subjects with higher eGFRs, variability in RBF explained by disease characteristics was similar for RBF{sub MRI} compared to RBF{sub Hip,} whereas in subjects with lower eGFRs, this was significantly less for RBF{sub MRI}. Our study shows that RBF can be measured accurately in ADPKD patients by phase-contrast, but this technique may be less feasible in subjects with a lower eGFR. (orig.)

  2. Magnetic Field Gradient Waveform Monitoring for Magnetic Resonance

    Science.gov (United States)

    Han, Hui

    Linear magnetic field gradients have played a central role in Magnetic Resonance Imaging (MRI) since Fourier Transform MRI was proposed three decades ago. Their primary function is to encode spatial information into MR signals. Magnetic field gradients are also used to sensitize the image contrast to coherent and/or incoherent motion, to selectively enhance an MR signal, and to minimize image artifacts. Modern MR imaging techniques increasingly rely on the implementation of complex gradient waveforms for the manipulation of spin dynamics. However, gradient system infidelities caused by eddy currents, gradient amplifier imperfections and group delays, often result in image artifacts and other errors (e.g., phase and intensity errors). This remains a critical problem for a wide range of MRI techniques on modern commercial systems, but is of particular concern for advanced MRI pulse sequences. Measuring the real magnetic field gradients, i.e., characterizing eddy currents, is critical to addressing and remedying this problem. Gradient measurement and eddy current calibration are therefore a general topic of importance to the science of MRI. The Magnetic Field Gradient Monitor (MFGM) idea was proposed and developed specifically to meet these challenges. The MFGM method is the heart of this thesis. MFGM methods permit a variety of magnetic field gradient problems to be investigated and systematically remedied. Eddy current effects associated with MR compatible metallic pressure vessels were analyzed, simulated, measured and corrected. The appropriate correction of eddy currents may enable most MR/MRI applications with metallic pressure vessels. Quantitative imaging (1D/2D) with model pressure vessels was successfully achieved by combining image reconstruction with MFGM determined gradient waveform behaviour. Other categories of MR applications with metallic vessels, including diffusion measurement and spin echo SPI T2 mapping, cannot be realized solely by MFGM guided

  3. Non-resonant magnetic braking on JET and TEXTOR

    DEFF Research Database (Denmark)

    Sun, Y.; Liang, Y.; Shaing, K.C.

    2012-01-01

    The non-resonant magnetic braking effect induced by a non-axisymmetric magnetic perturbation is investigated on JET and TEXTOR. The collisionality dependence of the torque induced by the n = 1, where n is the toroidal mode number, magnetic perturbation generated by the error field correction coil...

  4. More accurate quantification of pulmonary blood flow by magnetic resonance imaging than by lung perfusion scintigraphy in patients with fontan circulation.

    Science.gov (United States)

    Fratz, Sohrab; Hess, John; Schwaiger, Markus; Martinoff, Stefan; Stern, Heiko C

    2002-09-17

    Quantitative evaluation of pulmonary perfusion using lung perfusion scintigraphy in patients with atriopulmonary anastomosis (APA) or total cavopulmonary connection (TCPC) or partial cavopulmonary connection (PCPC) is difficult because of preferential draining of the venae cavae to one lung. Scintigraphy is the gold standard. Phase-velocity MRI (PV-MRI) is a new technique for determining pulmonary perfusion. The aim of this study was therefore to determine whether PV-MRI is more accurate than scintigraphy for quantitative evaluation of pulmonary perfusion ratios in patients with APA, TCPC, or PCPC. We studied 15 patients with APA, TCPC, or PCPC (16+/-7 years old, 4 female). Twelve patients (15+/-8 years old, 3 female) with a single pulmonary blood source supplied by a subpulmonary ventricle, ensuring complete mixing of the radioactive tracer before entering the pulmonary circulation, served as controls. Pulmonary scintigraphy and PV-MRI were performed in all patients. Bland-Altman analysis showed a clinically unacceptable difference of 7.1% right pulmonary blood flow (27.2% upper and -13.0% lower limit of agreement) between the two methods in the study group. The two methods agreed excellently in the control group (difference, 1.6%; 4.0% upper and -7.2% lower limit of agreement), showing that the bad agreement in the study group was caused by the problems encountered using pulmonary scintigraphy in patients with APA, TCPC, or PCPC. Because of preferential caval flow into either lung, PV-MRI is more accurate for evaluating pulmonary perfusion ratios than lung perfusion scintigraphy in patients with Fontan-like circulation.

  5. Tuning Coler Magnetic Current Apparatus with Magneto-Acoustic Resonance

    Science.gov (United States)

    Ludwig, Thorsten

    An attempt was made to tune the Coler magnetic current apparatus with the magneto acoustic resonance of the magnetic rods. Measurements with a replica of the famous Coler "Magnetstromapparat" were conducted. In order to tune the acoustic, magnetic and electric resonance circuits of the Coler device the magneto-acoustic resonance was measured with a frequency scan through a function generator and a lock-in amplifier. The frequency generator was powering a driving coil, while the lock-in was connected to a pickup coil. Both coils were placed on a magnetic rod. Resonances were observed up to the 17th harmonic. The quality Q of the observed resonances was 270. To study the magneto-acoustic resonance in the time domain a pair of Permendur rods were employed. The magneto-acoustic resonances of the Permendur rods were observed with an oscilloscope. Spectra of the magneto acoustic resonance were measured for the Permendur rods and for a Coler replica magnet in the frequency range from 25 kHz to 380 kHz. The next step was to bring the resonances of the Permendur rods close together so that they overlap. The 10thharmonic was chosen because it was close to the 180 kHz that Hans Coler related to ferromagnetism. Further more magneto-acoustic coupling between the Permendur rods was studied. Finally the question was explored if Hans Coler converted vacuum fluctuations via magnetic and acoustic resonance into electricity. There is a strong connection between magnetism and quantum field zero point energy (ZPE). An outlook is given on next steps in the experiments to unveil the working mechanism of the Coler magnetic current apparatus.

  6. Purcell factor of Mie resonators featuring electric and magnetic modes

    CERN Document Server

    Zambrana-Puyalto, Xavier

    2015-01-01

    We present a modal approach to compute the Purcell factor in Mie resonators exhibiting both electric and magnetic resonances. The analytic expressions of the normal modes are used to calculate the effective volumes. We show that important features of the effective volume can be predicted thanks to the translation-addition coefficients of a displaced dipole. Using our formalism, it is easy to see that, in general, the Purcell factor of Mie resonators is not dominated by a single mode, but rather by a large superposition. Finally we consider a silicon resonator homogeneously doped with electric dipolar emitters, and we show that the average electric Purcell factor dominates over the magnetic one.

  7. Real-time magnetic resonance imaging investigation of resonance tuning in soprano singing

    OpenAIRE

    Bresch, Erik; Narayanan, Shrikanth

    2010-01-01

    This article investigates using real-time magnetic resonance imaging the vocal tract shaping of 5 soprano singers during the production of two-octave scales of sung vowels. A systematic shift of the first vocal tract resonance frequency with respect to the fundamental is shown to exist for high vowels across all subjects. No consistent systematic effect on the vocal tract resonance could be shown across all of the subjects for other vowels or for the second vocal tract resonance.

  8. Magnetic Resonance Imaging in Pediatric Elbow Fractures

    Energy Technology Data Exchange (ETDEWEB)

    Pudas, T.; Hurme, T.; Mattila, K.; Svedstroem, E. [Univ. of Turku, (Finland). Depts. of Radiology and Pediatric Surgery

    2005-10-01

    Purpose: Magnetic resonance imaging (MRI) evaluation of pediatric elbow trauma with or without a visible fracture on radiography. Material and Methods: MRI was performed in the acute phase in 25 children with an elbow injury. Nine patients with an elbow effusion only on radiographs and 16 with a fracture or luxation seen on radiographs underwent subsequent MRI. No sedation was used. Results: MRI revealed eight occult fractures (89%) in seven out of nine patients who had only an effusion on radiographs. Based on MRI findings, septic arthritis was suspected in one patient. Two patients out of five with a supracondylar fracture on the radiograph had a cartilage lesion in the humerus. MRI depicted a 3-mm gap on the articular surface in two patients with a lateral condyle fracture, a more accurate fracture location in two patients than the radiographs, and an additional occult fracture in two patients. MRI showed a fracture not seen on radiographs in two of three patients with prior luxation. Conclusion: MRI is a sensitive and accurate method in the diagnosis of pediatric elbow injuries, especially when only an effusion is present on radiographs. Occult fractures are more common in pediatric patients with elbow injury than reported earlier.

  9. Magnetic resonance imaging in complex partial seizures

    Energy Technology Data Exchange (ETDEWEB)

    Furune, Sunao; Negoro, Tamiko; Maehara, Mitsuo; Nomura, Kazushi; Miura, Kiyokuni; Takahashi, Izumi; Watanabe, Kazuyoshi (Nagoya Univ. (Japan). Faculty of Medicine)

    1989-09-01

    Magnetic resonance imaging (MRI) and computed tomography (CT) were performed on 45 patients with intractable complex partial seizures. MRI was performed with a superconducting whole-body scanner operating at 0.5 tesla (T) and 1.5 T. In patients with temporal lobe epilepsy, 8 of 24 patients had abnormal CT, but 16 or 24 patients showed abnormal MRI. 1.5 T MRI detected more abnormality than 0.5 T MRI when CT was normal. In patients with frontal lobe epilepsy, 5 of 7 patients had normal CT and MRI. In 2 other patients, MRI demonstrated an arachnoid cyst and increased signal intensity area on the T2-weighted images which were not detected by CT. In patients with occipital lobe epilepsy, 5 of 6 patients show abnormal CT and MRI. In patients with tuberous sclerosis, MRI revealed some increased signal intensity areas on the T2-weighted images in the occipital and temporal lobe, which were not detected by CT. Most surface EEG foci corresponded with the side of MRI abnormality. These data indicate that MRI is more informative than CT in complex partial seizures. MRI is the imaging technique of choice in the diagnosis of complex partial seizures. (author).

  10. Focal liver lesions: Practical magnetic resonance imagingapproach

    Institute of Scientific and Technical Information of China (English)

    2015-01-01

    With the widespread of cross-sectional imaging, a growthof incidentally detected focal liver lesions (FLL) hasbeen observed. A reliable detection and characterizationof FLL is critical for optimal patient management.Maximizing accuracy of imaging in the context ofFLL is paramount in avoiding unnecessary biopsies,which may result in post-procedural complications. Atremendous development of new imaging techniqueshas taken place during these last years. Nowadays,Magnetic resonance imaging (MRI) plays a key rolein management of liver lesions, using a radiation-freetechnique and a safe contrast agent profile. MRI playsa key role in the non-invasive correct characterizationof FLL. MRI is capable of providing comprehensiveand highly accurate diagnostic information, withthe additional advantage of lack of harmful ionizingradiation. These properties make MRI the mainstay forthe noninvasive evaluation of focal liver lesions. In thispaper we review the state-of-the-art MRI liver protocol,briefly discussing different sequence types, the uniquecharacteristics of imaging non-cooperative patients anddiscuss the role of hepatocyte-specific contrast agents.A review of the imaging features of the most commonbenign and malignant FLL is presented, supplementedby a schematic representation of a simplistic practicalapproach on MRI.

  11. Magnetic resonance urography in pediatric urology.

    Science.gov (United States)

    Cerwinka, Wolfgang H; Kirsch, Andrew J

    2010-07-01

    Magnetic resonance urography (MRU) has evolved into an effective imaging tool for the evaluation of the urinary tract in children. The goal of this article is to describe current techniques and applications of MRU and to review recent advances. MRU is most commonly applied to the evaluation of hydronephrosis and provides valuable insight into a wide range of obstructive uropathies. MRU was shown to be superior to renal scintigraphy for the diagnosis of pyelonephritis and renal scarring. The use of MRU for the assessment of urolithiasis, vesicoureteral reflux, renal trauma, and fetal urinary tract abnormalities is limited and technical refinements are required. Judicious use of gadolinium-based contrast agents in patients at risk for nephrogenic systemic fibrosis was recently shown to avoid new occurrences. Potential future applications include virtual endoscopy and MRU-guided procedures. MRU has the potential to revolutionize imaging of the urinary tract in children. It integrates exquisite anatomical information with a variety of functional data and avoids ionizing radiation. MRU is increasingly employed as a problem solver when conventional imaging studies remain inconclusive and its growing application will likely improve availability and cost in the future.

  12. Endorectal magnetic resonance imaging in persistent hemospermia

    Directory of Open Access Journals (Sweden)

    Adilson Prando

    2008-03-01

    Full Text Available OBJECTIVE: To present the spectrum of abnormalities found at endorectal magnetic resonance imaging (E-MRI, in patients with persistent hemospermia. MATERIALS AND METHODS: A review of E-MRI findings observed in 86 patients with persistent hemospermia was performed and results compared with those reported in the literature. Follow-up was possible in 37 of 86 (43% patients with hemospermia. RESULTS: E-MRI showed abnormal findings in 52 of 86 (60% patients with hemospermia. These findings were: a hemorrhagic seminal vesicle and ejaculatory duct, isolated (n = 11 or 21% or associated with complicated midline prostatic cyst (n = 10 or 19.0%; b hemorrhagic chronic seminal vesiculitis, isolated (n = 14 or 27% or associated with calculi within dilated ejaculatory ducts (n = 2 or 4 %; c hemorrhagic seminal vesicle associated with calculi within dilated ejaculatory duct (n = 4 or 7.7% or within seminal vesicle (n = 4 or 7.7%; d non-complicated midline prostatic cyst (n = 6 or 11.5%; and e prostate cancer (n = 1 or 2%. Successful treatment was more frequent in patients with chronic inflammatory and/or obstructive abnormalities. CONCLUSION: E-MRI should be considered the modality of choice, for the evaluation of patients with persistent hemospermia.

  13. Endorectal magnetic resonance imaging in persistent hemospermia

    Energy Technology Data Exchange (ETDEWEB)

    Prando, Adilson [Vera Cruz Hospital, Campinas, SP (Brazil). Dept. of Radiology and Diagnostic Imaging

    2008-03-15

    Objective: To present the spectrum of abnormalities found at endorectal magnetic resonance imaging (E-MRI), in patients with persistent hemospermia. Materials and methods: A review of E-MRI findings observed in 86 patients with persistent hemospermia was performed and results compared with those reported in the literature. Follow-up was possible in 37 of 86 (43%) patients with hemospermia. Results: E-MRI showed abnormal findings in 52 of 86 (60%) patients with hemospermia. These findings were: a) hemorrhagic seminal vesicle and ejaculatory duct, isolated (n = 11 or 21%) or associated with complicated midline prostatic cyst (n = 10 or 19.0%); b) hemorrhagic chronic seminal vesiculitis, isolated (n = 14 or 27%) or associated with calculi within dilated ejaculatory ducts (n = 2 or 4 %); c) hemorrhagic seminal vesicle associated with calculi within dilated ejaculatory duct (n = 4 or 7.7%) or within seminal vesicle (n = 4 or 7.7%); d) non-complicated midline prostatic cyst (n = 6 or 11.5%); and e) prostate cancer (n = 1 or 2%). Successful treatment was more frequent in patients with chronic inflammatory and/or obstructive abnormalities. Conclusion: E-MRI should be considered the modality of choice, for the evaluation of patients with persistent hemospermia. (author)

  14. Magnetic resonance imaging of the normal placenta.

    Science.gov (United States)

    Blaicher, Wibke; Brugger, Peter C; Mittermayer, Christoph; Schwindt, Jens; Deutinger, Josef; Bernaschek, Gerhard; Prayer, Daniela

    2006-02-01

    The goal of this study was to provide a representative description of the normal placenta with contrast medium-free magnetic resonance imaging (MRI) in order to determine a standard of reference. One hundred consecutive singleton pregnancies were investigated by MRI without application of a contrast medium. The mean gestational age (GA) at the time of investigation was 29.5 weeks (range 19-40). Patients with suspected utero-placental insufficiency (UPI) or placental anomalies were excluded. Signal intensities were assessed and correlated with the respective GA. Antenatal MRI without contrast medium was able to depict placental status and morphological changes during gestation. A regular homogeneous structure was found in weeks 19-23. Subsequently, sporadic, slightly marked lobules appeared, which increased in number and markedness with ongoing gestation. Stratification of the lobules was observed after 36 weeks. The ratio of placental and amniotic fluid signal intensities decreased significantly with higher GA and with placental grading. MRI is well suited as an imaging method for the placenta. Our data may be used as a reference in the assessment of the placenta on MRI, and may have further clinical impact with respect to the determination of UPI.

  15. Magnetic resonance imaging of the normal placenta

    Energy Technology Data Exchange (ETDEWEB)

    Blaicher, Wibke [Department of Gynecology and Obstetrics, University Hospital Vienna (Austria)]. E-mail: wibke.blaicher@meduniwien.ac.at; Brugger, Peter C. [Center of Anatomy and Cell Biology, University Hospital of Vienna (Austria); Mittermayer, Christoph [Department of Pediatrics, Division of Neonatology and Intensive Care, University Hospital of Vienna (Austria); Schwindt, Jens [Department of Pediatrics, Division of Neonatology and Intensive Care, University Hospital of Vienna (Austria); Deutinger, Josef [Department of Gynecology and Obstetrics, University Hospital Vienna (Austria); Bernaschek, Gerhard [Department of Gynecology and Obstetrics, University Hospital Vienna (Austria); Prayer, Daniela [Department of Radiology, Division of Neuroradiology, University Hospital of Vienna (Austria)

    2006-02-15

    The goal of this study was to provide a representative description of the normal placenta with contrast medium-free magnetic resonance imaging (MRI) in order to determine a standard of reference. One hundred consecutive singleton pregnancies were investigated by MRI without application of a contrast medium. The mean gestational age (GA) at the time of investigation was 29.5 weeks (range 19-40). Patients with suspected utero-placental insufficiency (UPI) or placental anomalies were excluded. Signal intensities were assessed and correlated with the respective GA. Antenatal MRI without contrast medium was able to depict placental status and morphological changes during gestation. A regular homogeneous structure was found in weeks 19-23. Subsequently, sporadic, slightly marked lobules appeared, which increased in number and markedness with ongoing gestation. Stratification of the lobules was observed after 36 weeks. The ratio of placental and amniotic fluid signal intensities decreased significantly with higher GA and with placental grading. MRI is well suited as an imaging method for the placenta. Our data may be used as a reference in the assessment of the placenta on MRI, and may have further clinical impact with respect to the determination of UPI.

  16. Pancreatitis: computed tomography and magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, P.J.A.; Sheridan, M.B. [Dept. of Clinical Radiology, St. James' s University Hospital, Leeds (United Kingdom)

    2000-03-01

    The value of CT in management of severe acute pancreatitis is well established. Some, but not all, experimental studies suggest a detrimental effect of intravenous iodinated contrast agents in acute pancreatitis, but although initial clinical data tends to support this, the positive advantages of enhanced CT outweigh the possible risks. Magnetic resonance imaging has been shown to be as effective as CT in demonstrating the presence and extent of pancreatic necrosis and fluid collections, and probably superior in indicating the suitability of such collections for percutaneous drainage. Image-guided intervention remains a key approach in the management of severely ill patients, and the indications, techniques and results of radiological intervention are reviewed herein. Both CT and MRI can be used to diagnose advanced chronic pancreatitis, with the recent addition of MRCP as a viable alternative to diagnostic endoscopic retrograde cholangiopancreatography (ERCP). Both MRCP and CT/MR imaging of the pancreatic parenchyma still have limitations in the recognition of the earliest changes of chronic pancreatitis - for which ERCP and tests of pancreatic function remain more sensitive - but the clinical significance of these minor changes remains contentious. (orig.)

  17. Potts disease: Diagnosis with magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Pursey, Jacqueline [MRI Department, Gartnavel General Hospitial, 1053 Great Western road, Glasgow G12 0YN (United Kingdom)], E-mail: Jacqueline.pursey@ggc.scot.nhs.uk; Stewart, Sharon [School of Health and Social Care, Caledonian University, Glasgow (United Kingdom)

    2010-02-15

    The eponymously named Potts disease is a relatively rare form of Tuberculosis (TB) which affects the spine. TB of the spine is one of the earliest diseases known to man and in the 20th century was thought to be a disease which had been defeated by the advent of antitubercular drugs. Over the last two decades there have been several reports which indicate a revival of TB in both the developing and developed world. Factors which may be contributing to this are the spread of the HIV virus, increased immigration and the emergence of drug resistant strains of the TB bacteria. Potts disease has an insidious onset and often the radiographic findings are far advanced when a diagnosis is finally reached. MRI is able to detect changes to the vertebrae in Potts disease earlier than radiographs. This case report outlines the clinical presentation of a young male with Potts disease who was HIV negative, and the important role that MRI plays in diagnosis and therefore in appropriate and timely intervention. The typical magnetic resonance (MR) imaging features and the radiographic hallmarks of the disease will also be discussed.

  18. Magnetic resonance imaging of cystic periventricular leukomalacia

    Energy Technology Data Exchange (ETDEWEB)

    Kadoi, Nobuaki; Nomura, Junko; Nowatari, Masahiko; Ohta, Takeo; Kamohara, Takashi; Yashiro, Kimio (Kitasato Univ., Sagamihara, Kanagawa (Japan). School of Medicine)

    1990-08-01

    A study was performed to assess the values of magnetic resonance (MR) imaging in evaluation and the follow up of patients with cystic periventricular leukomalacia. Ten patients selected for MR imaging were diagnosed as having periventricular cystic lesions based on US scans. The range of gestational ages was 27 to 32 weeks, and the range of birth weights was 927 to 2,046 g. Twenty MR examinations were carried out using a 0.5 T superconducting system (Resona; Yokogawa). On the first MR examinations, taken by 6 months of age, low signal intensity lesions within the periventricular white matter, moderate ventriculomegaly with irregularity of the ventricular wall and delayed myelination were observed. These were the MR findings observed in the subacute stage of PVL. On the second or the third MR examinations, taken after 12 months of age, increased signal intensity in periventricular white matter on T{sub 2} weighted images decreased volume of periventricular white matter and centrum semiovale and the ventriculomagaly with irregularity of ventricular wall were observed. However, progressions of myelination were proved to be not delayed in comparison with age matched controls. These were thought to be the MR findings of late stage of PVL. As the US findings of PVL have good correlation with pathologic changes revealed at autopsy, MR imaging can depict myelination and detect PVL lesion beyond the neonatal period. These observations demonstrate the value of the MR imaging for the follow up of the patients with PVL beyond the time of fontanel closure. (author).

  19. Statistical normalization techniques for magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Russell T. Shinohara

    2014-01-01

    Full Text Available While computed tomography and other imaging techniques are measured in absolute units with physical meaning, magnetic resonance images are expressed in arbitrary units that are difficult to interpret and differ between study visits and subjects. Much work in the image processing literature on intensity normalization has focused on histogram matching and other histogram mapping techniques, with little emphasis on normalizing images to have biologically interpretable units. Furthermore, there are no formalized principles or goals for the crucial comparability of image intensities within and across subjects. To address this, we propose a set of criteria necessary for the normalization of images. We further propose simple and robust biologically motivated normalization techniques for multisequence brain imaging that have the same interpretation across acquisitions and satisfy the proposed criteria. We compare the performance of different normalization methods in thousands of images of patients with Alzheimer's disease, hundreds of patients with multiple sclerosis, and hundreds of healthy subjects obtained in several different studies at dozens of imaging centers.

  20. Magnetic resonance imaging in retropharyngeal tendinitis

    Energy Technology Data Exchange (ETDEWEB)

    Ekbon, K.; Annell, K.; Traeff, J.; Torhall, J. (Soeder Hospital, Stockholm (Sweden))

    1994-08-01

    Seven consecutive patients with acute retropharyngeal tendinitis underwent plain X-ray and magnetic resonance imaging (MRI) of the cervical spine. All seven had marked soft tissue swelling anterior to C1 and C2 on plain X-ray, and soft tissue calcification at this level was present in five of them. On MRI, there was markedly increased signal intensity on T[sub 2]-weighted images in the acute phase and intermediate signal intensity on T[sub 1]-weighted images, anterior to the level of CI and C2, often extending as far down as C6. These changes correlated well with the soft tissue swelling seen on conventional X-ray of the cervical spine. The maximum mid-sagittal thickness of the soft issues was significantly greater in the tendinitis patients than in 12 control subjects free of symptoms from the pharynx or the cervical spine. Treatment with non-steroidal anti-inflammatory drugs rapidly alleviated symptoms, and at follow-up MRI showed regression or complete restitution of the changes. In conclusion, MRI can visualize the edematous changes in the longus colli muscle and adds useful diagnostic information in suspected cases of acute retropharyngeal tendinitis. 9 refs., 4 figs., 3 tabs.

  1. Compression-sensitive magnetic resonance elastography

    Science.gov (United States)

    Hirsch, Sebastian; Beyer, Frauke; Guo, Jing; Papazoglou, Sebastian; Tzschaetzsch, Heiko; Braun, Juergen; Sack, Ingolf

    2013-08-01

    Magnetic resonance elastography (MRE) quantifies the shear modulus of biological tissue to detect disease. Complementary to the shear elastic properties of tissue, the compression modulus may be a clinically useful biomarker because it is sensitive to tissue pressure and poromechanical interactions. In this work, we analyze the capability of MRE to measure volumetric strain and the dynamic bulk modulus (P-wave modulus) at a harmonic drive frequency commonly used in shear-wave-based MRE. Gel phantoms with various densities were created by introducing CO2-filled cavities to establish a compressible effective medium. The dependence of the effective medium's bulk modulus on phantom density was investigated via static compression tests, which confirmed theoretical predictions. The P-wave modulus of three compressible phantoms was calculated from volumetric strain measured by 3D wave-field MRE at 50 Hz drive frequency. The results demonstrate the MRE-derived volumetric strain and P-wave modulus to be sensitive to the compression properties of effective media. Since the reconstruction of the P-wave modulus requires third-order derivatives, noise remains critical, and P-wave moduli are systematically underestimated. Focusing on relative changes in the effective bulk modulus of tissue, compression-sensitive MRE may be useful for the noninvasive detection of diseases involving pathological pressure alterations such as hepatic hypertension or hydrocephalus.

  2. Magnetic resonance angiography in suspected cerebral vasculitis

    Energy Technology Data Exchange (ETDEWEB)

    Demaerel, Philippe; De Ruyter, Nele; Wilms, Guido [Department of Radiology, Universitair Ziekenhuis, KU Leuven, 3000, Leuven (Belgium); Maes, Frederik [Department of Medical Imaging Computing, Universitair Ziekenhuis, KU Leuven, 3000, Leuven (Belgium); Velghe, Beatrijs [Department of Radiology, Ziekenhuis Oost-Limburg, Schiepse Bos 6, 3600, Genk (Belgium)

    2004-06-01

    The purpose of this study was to determine the technical capacity and diagnostic accuracy of 3D time-of-flight magnetic resonance angiography (MRA) in suspected cerebral vasculitis in a retrospective analysis of MRA and digital subtraction angiography (DSA) in 14 young patients with clinical and/or radiological suspicion of cerebral vasculitis. A total of nine arteries were evaluated in each patient. Consensus review of DSA by three observers was the reference standard. The sensitivity for detecting a stenosis varied from 62 to 79% for MRA and from 76 to 94% for DSA, depending on the observer. The specificity for detecting a stenosis varied from 83 to 87% for MRA and from 83 to 97% for DSA. Using the criterion ''more than two stenoses in at least two separate vascular distributions'' to consider the examination as being true positive, the false-positive rates for MRA and DSA were comparable. MRA plays a role as the first angiographical examination in the diagnostic work-up of suspected cerebral vasculitis. When more than two stenoses in at least two separate vascular distributions are depicted on MRA, DSA is not expected to add a significant diagnostic contribution in a patient with suspected cerebral vasculitis. DSA remains necessary when MRA is normal or when less than three stenoses are seen. (orig.)

  3. Meralgia paresthetica: 3-Tesla magnetic resonance neurography.

    Science.gov (United States)

    Chhabra, Avneesh; Del Grande, Filippo; Soldatos, Theodoros; Chalian, Majid; Belzberg, Allan J; Williams, Eric H; Jalali, Farahani S; Thawait, Gaurav K; Eng, John; Carrino, John A

    2013-06-01

    To assess the diagnostic accuracy and observer performance of 3-Tesla magnetic resonance neurography (MRN) in the evaluation of meralgia paresthetica (MP). Two independent readers were blinded to the clinical diagnosis and evaluated the MRN studies of the pelvis of 11 patients with MP and 28 control participants. In each study, the lateral femoral cutaneous nerves were assessed for signal alteration and/or neuroma formation, indicating lateral femoral cutaneous neuropathy, at various levels along their course. Intra- and inter-observer reliability was evaluated. Both readers exhibited substantial intraobserver agreement in detecting signal alterations and neuroma formation of the lateral femoral cutaneous nerve (LFCN). The readers demonstrated moderate interobserver agreement in detecting signal alteration of the LFCN and poor interobserver agreement in diagnosing neuroma formation. Sensitivity, specificity, positive predictive value, and negative predictive value of LFCN neuropathy diagnosis were ≥ 71 % and ≥ 94 % for both readers respectively. The diagnostic test accuracy was ≥ 90 % for both readers. 3-Tesla MRN provides reliable and accurate diagnostic evaluation of meralgia paresthetica.

  4. Neural network segmentation of magnetic resonance images

    Science.gov (United States)

    Frederick, Blaise

    1990-07-01

    Neural networks are well adapted to the task of grouping input patterns into subsets which share some similarity. Moreover once trained they can generalize their classification rules to classify new data sets. Sets of pixel intensities from magnetic resonance (MR) images provide a natural input to a neural network by varying imaging parameters MR images can reflect various independent physical parameters of tissues in their pixel intensities. A neural net can then be trained to classify physically similar tissue types based on sets of pixel intensities resulting from different imaging studies on the same subject. A neural network classifier for image segmentation was implemented on a Sun 4/60 and was tested on the task of classifying tissues of canine head MR images. Four images of a transaxial slice with different imaging sequences were taken as input to the network (three spin-echo images and an inversion recovery image). The training set consisted of 691 representative samples of gray matter white matter cerebrospinal fluid bone and muscle preclassified by a neuroscientist. The network was trained using a fast backpropagation algorithm to derive the decision criteria to classify any location in the image by its pixel intensities and the image was subsequently segmented by the classifier. The classifier''s performance was evaluated as a function of network size number of network layers and length of training. A single layer neural network performed quite well at

  5. Antepartum pelvimetry by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Koshiba, Hisato; Kikuchi, Noriko; Ogino, Yoshio [Kyoto Second Red Cross Hospital (Japan)] (and others)

    2001-09-01

    Evaluation of the pelvis by pelvimetry plays an important role in selecting patients for possible vaginal delivery. However, x-ray pelvimetry involves the disadvantage of fetal exposure to ionizing radiation. The clear advantage of magnetic resonance imaging (MRI) pelvimetry is that this procedure is free from ionizing radiation. Measurements with MRI are as reliable as those with x-ray pelvimetry and the contrast of MRI is even better. MRI shows soft-tissue structures as well as bone. The use of this scanning technique is contraindicated for patients with pacemakers. But, pacemakers are rarely encountered in young pregnant women. In our department, 203 patients underwent antepartum pelvimetry with MRI during the last 5 years. T1-weighted mediosagittal images were used for measurement of the obstetric conjugate (OC) and to determine whether a straight sacrum can be recognized. Data were compared between patients who had undergone cesarean section due to cephalopelvic disproportion (CPD) and patients who experienced vaginal delivery. OC and OC-biparietal diameter were significantly different between the two groups. MRI can be further used for the diagnosis of CPD and to select patients for whom planned vaginal delivery is appropriate. (author)

  6. Cardiovascular magnetic resonance in pericardial diseases

    Directory of Open Access Journals (Sweden)

    Francone Marco

    2009-05-01

    Full Text Available Abstract The pericardium and pericardial diseases in particular have received, in contrast to other topics in the field of cardiology, relatively limited interest. Today, despite improved knowledge of pathophysiology of pericardial diseases and the availability of a wide spectrum of diagnostic tools, the diagnostic challenge remains. Not only the clinical presentation may be atypical, mimicking other cardiac, pulmonary or pleural diseases; in developed countries a shift for instance in the epidemiology of constrictive pericarditis has been noted. Accurate decision making is crucial taking into account the significant morbidity and mortality caused by complicated pericardial diseases, and the potential benefit of therapeutic interventions. Imaging herein has an important role, and cardiovascular magnetic resonance (CMR is definitely one of the most versatile modalities to study the pericardium. It fuses excellent anatomic detail and tissue characterization with accurate evaluation of cardiac function and assessment of the haemodynamic consequences of pericardial constraint on cardiac filling. This review focuses on the current state of knowledge how CMR can be used to study the most common pericardial diseases.

  7. Constraining groundwater modeling with magnetic resonance soundings.

    Science.gov (United States)

    Boucher, Marie; Favreau, Guillaume; Nazoumou, Yahaya; Cappelaere, Bernard; Massuel, Sylvain; Legchenko, Anatoly

    2012-01-01

    Magnetic resonance sounding (MRS) is a noninvasive geophysical method that allows estimating the free water content and transmissivity of aquifers. In this article, the ability of MRS to improve the reliability of a numerical groundwater model is assessed. Thirty-five sites were investigated by MRS over a ∼5000 km(2) domain of the sedimentary Continental Terminal aquifer in SW Niger. Time domain electromagnetic soundings were jointly carried out to estimate the aquifer thickness. A groundwater model was previously built for this section of the aquifer and forced by the outputs from a distributed surface hydrology model, to simulate the observed long-term (1992 to 2003) rise in the water table. Uncertainty analysis had shown that independent estimates of the free water content and transmissivity values of the aquifer would facilitate cross-evaluation of the surface-water and groundwater models. MRS results indicate ranges for permeability (K = 1 × 10(-5) to 3 × 10(-4) m/s) and for free water content (w = 5% to 23% m(3) /m(3) ) narrowed by two orders of magnitude (K) and by ∼50% (w), respectively, compared to the ranges of permeability and specific yield values previously considered. These shorter parameter ranges result in a reduction in the model's equifinality (whereby multiple combinations of model's parameters are able to represent the same observed piezometric levels), allowing a better constrained estimate to be derived for net aquifer recharge (∼22 mm/year).

  8. Magnetic resonance imaging of pelvic endometriosis.

    Science.gov (United States)

    Méndez Fernández, R; Barrera Ortega, J

    Endometriosis is common in women of reproductive age; it can cause pelvic pain and infertility. It is important to diagnose endometriosis and to thoroughly evaluate its extension, especially when surgical treatment is being considered. Magnetic resonance imaging (MRI) with careful examination technique and interpretation enables more accurate and complete diagnosis and staging than ultrasonography, especially in cases of deep pelvic endometriosis. Furthermore, MRI can identify implants in sites that can be difficult to access in endoscopic or laparoscopic explorations. In this article, we describe the appropriate MRI protocol for the study of pelvic endometriosis and the MRI signs of pelvic organ involvement. It is necessary to know the subtle findings and to look for them so we can ensure that they are not overlooked. We describe clinical grading systems for endometriosis and review the diagnostic efficacy of MRI in comparison with other imaging techniques and surgery. Copyright © 2017 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Magnetic resonance imaging (MRI) in parasinus mucocele

    Energy Technology Data Exchange (ETDEWEB)

    Kakisu, Yonetsugu; Watanabe, Yoshihiro (Chiba Univ. (Japan). School of Medicine)

    1989-07-01

    We evaluated the clinical value of magnetic resonance imaging (MRI) in 9 cases of parasinus mucocele. The series included frontal mucocele 1 case, frontal and anterior ethmoidal mucocele 3 cases, anterior mucocele 2 cases, posterior ethmoidal mucocele 2 cases, and maxillary mucocele 1 case. MRI was performed with proton density P (300), inversion recovery IR (1000, 350), and spin echo SE (1000, 60/90) with 0.1 tesla resistive conducting system, or with T/sub 1/-weighted SE (440, 40), IR (1500, 500) and T/sub 2/-weighted SE (1500, 500) with 0.5 tesla superconducting system. We obtained images of variable intensities when employing P, IR and T/sub 1/-weighted SE imaging. It was possible to differentiate mucocele from normal orbital tissue by comparison with T/sub 2/-weighted imaging. All the 9 cases manifested a high intensity of T/sub 2/-weighted images. The findings were suggestive of a possibility to verify the content to parasinus cysts by MRI findings. (author).

  10. Magnetic resonance tomography of the knee joint

    Energy Technology Data Exchange (ETDEWEB)

    Puig, Stefan; Kuruvilla, Yojena Chittazhathu Kurian; Ebner, Lukas [University Hospital, University of Berne, Department of Interventional, Pediatric and Diagnostic Radiology Inselspital, Berne (Switzerland); Endel, Gottfried [Main Association of Austrian Social Insurance Institutions, Vienna (Austria)

    2015-10-15

    To compare the diagnostic performance of magnetic resonance imaging (MRI) in terms of sensitivity and specificity using a field strength of <1.0 T (T) versus ≥1.5 T for diagnosing or ruling out knee injuries or knee pathologies. The systematic literature research revealed more than 10,000 references, of which 1598 abstracts were reviewed and 87 full-text articles were retrieved. The further selection process resulted in the inclusion of four systematic reviews and six primary studies. No differences could be identified in the diagnostic performance of low- versus high-field MRI for the detection or exclusion of meniscal or cruciate ligament tears. Regarding the detection or grading of cartilage defects and osteoarthritis of the knee, the existing evidence suggests that high-field MRI is tolerably specific but not very sensitive, while there is literally no evidence for low-field MRI because only a few studies with small sample sizes and equivocal findings have been performed. We can recommend the use of low-field strength MRI systems in suspected meniscal or cruciate ligament injuries. This does, however, not apply to the diagnosis and grading of knee cartilage defects and osteoarthritis because of insufficient evidence. (orig.)

  11. NUCLEAR MAGNETIC RESONANCE STUDIES OF URANOCENES

    Energy Technology Data Exchange (ETDEWEB)

    Luke, Wayne D.; Streitwieser, Jr., Andrew

    1979-12-01

    In the past several years a substantial amount of work has been devoted toward evaluation of the contact and pseudocontact contributions to the observed isotropic shifts in H nuclear magnetic resonance (NMR) spectra of uranium(IV) organometallic compounds. One reason for interest in this area arises from using the presence of contact shifts as a prcbe for covalent character in the uranium carbon bonds in these compounds. Several extensive {sup 1}H NNR studies on Cp{sub 3} U-X compounds and less extensive studies on uranocenes have been reported. Interpretation of these results suggests that contact shifts-contribute significantly to the observed isotropic shifts. Their presence has been taken as indicative of covalent character of metal carbon bonds in these systems, but agreement is not complete. In this paper we shall review critically the work reported on uranocenes in the light of recent results and report recent work on attempted separation of the observed isotropic shifts in alkyluranocenes into contact and pseudocontact components.

  12. Magnetic resonance imaging of cerebellopontine angle lesions

    Directory of Open Access Journals (Sweden)

    Pratiksha Yadav

    2015-01-01

    Full Text Available Background: Cerebellopontine angle (CPA tumors are usually benign, and they are divided into extra-axial, intra-axial, extradural, and petrous axis tumors. CPA pathologies can be asymptomatic or it may present with vertigo, tinnitus, or unilateral hearing loss depending upon the site of tumor origin and displacement of the neurovascular structure. Aim and Objectives: To evaluate the role of magnetic resonance imaging (MRI aided with contrast-enhanced MRI as an imaging modality for diagnosis of CPA lesions. Materials and Methods: Analysis of 36 patients of CPA lesions over a period of 2 years was done. MRI was performed on Siemens 1.5 Tesla MAGNETOM Avanto Machine. Conclusion: There are spectrums of pathologies, which can present with these symptoms, which includes tumors, vascular malformations, and vascular loop compressing vestibulocochlear nerve or mastoid pathology so it is important to investigate the patient by MRI. Contrast-enhanced MRI is the most sensitive investigation in the evaluation of the CPA lesions, its characteristic, and its extent.

  13. Magnetic resonance imaging in glenohumeral instability

    Science.gov (United States)

    Jana, Manisha; Gamanagatti, Shivanand

    2011-01-01

    The glenohumeral joint is the most commonly dislocated joint of the body and anterior instability is the most common type of shoulder instability. Magnetic resonance (MR) imaging, and more recently, MR arthrography, have become the essential investigation modalities of glenohumeral instability, especially for pre-procedure evaluation before arthroscopic surgery. Injuries associated with glenohumeral instability are variable, and can involve the bones, the labor-ligamentous components, or the rotator cuff. Anterior instability is associated with injuries of the anterior labrum and the anterior band of the inferior glenohumeral ligament, in the form of Bankart lesion and its variants; whereas posterior instability is associated with reverse Bankart and reverse Hill-Sachs lesion. Multidirectional instability often has no labral pathology on imaging but shows specific osseous changes such as increased chondrolabral retroversion. This article reviews the relevant anatomy in brief, the MR imaging technique and the arthrographic technique, and describes the MR findings in each type of instability as well as common imaging pitfalls. PMID:22007285

  14. Magnetic Resonance Imaging Features of Neuromyelitis Optica

    Energy Technology Data Exchange (ETDEWEB)

    You, Sun Kyung; Song, Chang June; Park, Woon Ju; Lee, In Ho; Son, Eun Hee [Chungnam National University College of Medicine, Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2013-03-15

    To report the magnetic resonance (MR) imaging features of the spinal cord and brain in patients of neuromyelitis optica (NMO). Between January 2001 and March 2010, the MR images (spinal cord, brain, and orbit) and the clinical and serologic findings of 11 NMO patients were retrospectively reviewed. The contrast-enhancement of the spinal cord was performed (20/23). The presence and pattern of the contrast-enhancement in the spinal cord were classified into 5 types. Acute myelitis was monophasic in 8 patients (8/11, 72.7%); and optic neuritis preceded acute myelitis in most patients. Longitudinally extensive cord lesion (average, 7.3 vertebral segments) was involved. The most common type was the diffuse and subtle enhancement of the spinal cord with a multifocal nodular, linear or segmental intense enhancement (45%). Most of the brain lesions (5/11, 10 lesions) were located in the brain stem, thalamus and callososeptal interphase. Anti-Ro autoantibody was positive in 2 patients, and they showed a high relapse rate of acute myelitis. Anti-NMO IgG was positive in 4 patients (4/7, 66.7%). The imaging findings of acute myelitis in NMO may helpful in making an early diagnosis of NMO which can result in a severe damage to the spinal cord, and to make a differential diagnosis of multiple sclerosis and inflammatory diseases of the spinal cord such as toxocariasis.

  15. Bolus characteristics based on Magnetic Resonance Angiography

    Directory of Open Access Journals (Sweden)

    Bi Xiaoming

    2006-10-01

    Full Text Available Abstract Background A detailed contrast bolus propagation model is essential for optimizing bolus-chasing Computed Tomography Angiography (CTA. Bolus characteristics were studied using bolus-timing datasets from Magnetic Resonance Angiography (MRA for adaptive controller design and validation. Methods MRA bolus-timing datasets of the aorta in thirty patients were analyzed by a program developed with MATLAB. Bolus characteristics, such as peak position, dispersion and bolus velocity, were studied. The bolus profile was fit to a convolution function, which would serve as a mathematical model of bolus propagation in future controller design. Results The maximum speed of the bolus in the aorta ranged from 5–13 cm/s and the dwell time ranged from 7–13 seconds. Bolus characteristics were well described by the proposed propagation model, which included the exact functional relationships between the parameters and aortic location. Conclusion The convolution function describes bolus dynamics reasonably well and could be used to implement the adaptive controller design.

  16. Segmentation of neuroanatomy in magnetic resonance images

    Science.gov (United States)

    Simmons, Andrew; Arridge, Simon R.; Barker, G. J.; Tofts, Paul S.

    1992-06-01

    Segmentation in neurological magnetic resonance imaging (MRI) is necessary for feature extraction, volume measurement and for the three-dimensional display of neuroanatomy. Automated and semi-automated methods offer considerable advantages over manual methods because of their lack of subjectivity, their data reduction capabilities, and the time savings they give. We have used dual echo multi-slice spin-echo data sets which take advantage of the intrinsically multispectral nature of MRI. As a pre-processing step, a rf non-uniformity correction is applied and if the data is noisy the images are smoothed using a non-isotropic blurring method. Edge-based processing is used to identify the skin (the major outer contour) and the eyes. Edge-focusing has been used to significantly simplify edge images and thus allow simple postprocessing to pick out the brain contour in each slice of the data set. Edge- focusing is a technique which locates significant edges using a high degree of smoothing at a coarse level and tracks these edges to a fine level where the edges can be determined with high positional accuracy. Both 2-D and 3-D edge-detection methods have been compared. Once isolated, the brain is further processed to identify CSF, and, depending upon the MR pulse sequence used, the brain itself may be sub-divided into gray matter and white matter using semi-automatic contrast enhancement and clustering methods.

  17. Magnetic Resonance Imaging of Cartilage Repair

    Science.gov (United States)

    Trattnig, Siegfried; Winalski, Carl S.; Marlovits, Stephan; Jurvelin, Jukka S.; Welsch, Goetz H.; Potter, Hollis G.

    2011-01-01

    Articular cartilage lesions are a common pathology of the knee joint, and many patients may benefit from cartilage repair surgeries that offer the chance to avoid the development of osteoarthritis or delay its progression. Cartilage repair surgery, no matter the technique, requires a noninvasive, standardized, and high-quality longitudinal method to assess the structure of the repair tissue. This goal is best fulfilled by magnetic resonance imaging (MRI). The present article provides an overview of the current state of the art of MRI of cartilage repair. In the first 2 sections, preclinical and clinical MRI of cartilage repair tissue are described with a focus on morphological depiction of cartilage and the use of functional (biochemical) MR methodologies for the visualization of the ultrastructure of cartilage repair. In the third section, a short overview is provided on the regulatory issues of the United States Food and Drug Administration (FDA) and the European Medicines Agency (EMEA) regarding MR follow-up studies of patients after cartilage repair surgeries. PMID:26069565

  18. Magnetic resonance imaging at ultrahigh fields.

    Science.gov (United States)

    Ugurbil, Kamil

    2014-05-01

    Since the introduction of 4 T human systems in three academic laboratories circa 1990, rapid progress in imaging and spectroscopy studies in humans at 4 T and animal model systems at 9.4 T have led to the introduction of 7 T and higher magnetic fields for human investigation at about the turn of the century. Work conducted on these platforms has demonstrated the existence of significant advantages in SNR and biological information content at these ultrahigh fields, as well as the presence of numerous challenges. Primary difference from lower fields is the deviation from the near field regime; at the frequencies corresponding to hydrogen resonance conditions at ultrahigh fields, the RF is characterized by attenuated traveling waves in the human body, which leads to image nonuniformities for a given sample-coil configuration because of interferences. These nonuniformities were considered detrimental to the progress of imaging at high field strengths. However, they are advantageous for parallel imaging for signal reception and parallel transmission, two critical technologies that account, to a large extend, for the success of ultrahigh fields. With these technologies, and improvements in instrumentation and imaging methods, ultrahigh fields have provided unprecedented gains in imaging of brain function and anatomy, and started to make inroads into investigation of the human torso and extremities. As extensive as they are, these gains still constitute a prelude to what is to come given the increasingly larger effort committed to ultrahigh field research and development of ever better instrumentation and techniques.

  19. Science Drivers and Technical Challenges for Advanced Magnetic Resonance

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Karl T.; Pruski, Marek; Washton, Nancy M.; Lipton, Andrew S.

    2013-03-07

    This report recaps the "Science Drivers and Technical Challenges for Advanced Magnetic Resonance" workshop, held in late 2011. This exploratory workshop's goal was to discuss and address challenges for the next generation of magnetic resonance experimentation. During the workshop, participants from throughout the world outlined the science drivers and instrumentation demands for high-field dynamic nuclear polarization (DNP) and associated magnetic resonance techniques, discussed barriers to their advancement, and deliberated the path forward for significant and impactful advances in the field.

  20. Correlation of Magnetic Resonance Imaging Tumor Volume with Histopathology

    Science.gov (United States)

    Turkbey, Baris; Mani, Haresh; Aras, Omer; Rastinehad, Ardeshir R.; Shah, Vijay; Bernardo, Marcelino; Pohida, Thomas; Daar, Dagane; Benjamin, Compton; McKinney, Yolanda L.; Linehan, W. Marston; Wood, Bradford J.; Merino, Maria J.; Choyke, Peter L.; Pinto, Peter A.

    2017-01-01

    Purpose The biology of prostate cancer may be influenced by the index lesion. The definition of index lesion volume is important for appropriate decision making, especially for image guided focal treatment. We determined the accuracy of magnetic resonance imaging for determining index tumor volume compared with volumes derived from histopathology. Materials and Methods We evaluated 135 patients (mean age 59.3 years) with a mean prostate specific antigen of 6.74 ng/dl who underwent multiparametric 3T endorectal coil magnetic resonance imaging of the prostate and subsequent radical prostatectomy. Index tumor volume was determined prospectively and independently by magnetic resonance imaging and histopathology. The ellipsoid formula was applied to determine histopathology tumor volume, whereas manual tumor segmentation was used to determine magnetic resonance tumor volume. Histopathology tumor volume was correlated with age and prostate specific antigen whereas magnetic resonance tumor volume involved Pearson correlation and linear regression methods. In addition, the predictive power of magnetic resonance tumor volume, prostate specific antigen and age for estimating histopathology tumor volume (greater than 0.5 cm3) was assessed by ROC analysis. The same analysis was also conducted for the 1.15 shrinkage factor corrected histopathology data set. Results There was a positive correlation between histopathology tumor volume and magnetic resonance tumor volume (Pearson coefficient 0.633, p <0.0001), but a weak correlation between prostate specific antigen and histopathology tumor volume (Pearson coefficient 0.237, p=0.003). On linear regression analysis histopathology tumor volume and magnetic resonance tumor volume were correlated (r2=0.401, p <0.00001). On ROC analysis AUC values for magnetic resonance tumor volume, prostate specific antigen and age in estimating tumors larger than 0.5 cm3 at histopathology were 0.949 (p <0.0000001), 0.685 (p=0.001) and 0.627 (p=0