WorldWideScience

Sample records for flow cytometric cell

  1. Detection of circulating immune complexes by Raji cell assay: comparison of flow cytometric and radiometric methods

    International Nuclear Information System (INIS)

    Kingsmore, S.F.; Crockard, A.D.; Fay, A.C.; McNeill, T.A.; Roberts, S.D.; Thompson, J.M.

    1988-01-01

    Several flow cytometric methods for the measurement of circulating immune complexes (CIC) have recently become available. We report a Raji cell flow cytometric assay (FCMA) that uses aggregated human globulin (AHG) as primary calibrator. Technical advantages of the Raji cell flow cytometric assay are discussed, and its clinical usefulness is evaluated in a method comparison study with the widely used Raji cell immunoradiometric assay. FCMA is more precise and has greater analytic sensitivity for AHG. Diagnostic sensitivity by the flow cytometric method is superior in systemic lupus erythematosus (SLE), rheumatoid arthritis, and vasculitis patients: however, diagnostic specificity is similar for both assays, but the reference interval of FCMA is narrower. Significant correlations were found between CIC levels obtained with both methods in SLE, rheumatoid arthritis, and vasculitis patients and in longitudinal studies of two patients with cerebral SLE. The Raji cell FCMA is recommended for measurement of CIC levels to clinical laboratories with access to a flow cytometer

  2. Detection of circulating immune complexes by Raji cell assay: comparison of flow cytometric and radiometric methods

    Energy Technology Data Exchange (ETDEWEB)

    Kingsmore, S.F.; Crockard, A.D.; Fay, A.C.; McNeill, T.A.; Roberts, S.D.; Thompson, J.M.

    1988-01-01

    Several flow cytometric methods for the measurement of circulating immune complexes (CIC) have recently become available. We report a Raji cell flow cytometric assay (FCMA) that uses aggregated human globulin (AHG) as primary calibrator. Technical advantages of the Raji cell flow cytometric assay are discussed, and its clinical usefulness is evaluated in a method comparison study with the widely used Raji cell immunoradiometric assay. FCMA is more precise and has greater analytic sensitivity for AHG. Diagnostic sensitivity by the flow cytometric method is superior in systemic lupus erythematosus (SLE), rheumatoid arthritis, and vasculitis patients: however, diagnostic specificity is similar for both assays, but the reference interval of FCMA is narrower. Significant correlations were found between CIC levels obtained with both methods in SLE, rheumatoid arthritis, and vasculitis patients and in longitudinal studies of two patients with cerebral SLE. The Raji cell FCMA is recommended for measurement of CIC levels to clinical laboratories with access to a flow cytometer.

  3. Single-Cell Phosphospecific Flow Cytometric Analysis of Canine and Murine Adipose-Derived Stem Cells

    Directory of Open Access Journals (Sweden)

    Harumichi Itoh

    2017-01-01

    Full Text Available This study aimed to demonstrate single-cell phosphospecific flow cytometric analysis of canine and murine adipose-derived stem/stromal cells (ADSCs. ADSCs were obtained from clinically healthy laboratory beagles and C57BL/6 mice. Cell differentiation into adipocytes, osteocytes, and chondrocytes was observed for the cultured canine ADSCs (cADSCs and murine ADSCs (mADSCs to determine their multipotency. We also performed single-cell phosphospecific flow cytometric analysis related to cell differentiation and stemness. Cultured cADSCs and mADSCs exhibited the potential to differentiate into adipocytes, osteocytes, and chondrocytes. In addition, single-cell phosphospecific flow cytometric analysis revealed similar β-catenin and Akt phosphorylation between mADSCs and cADSCs. On the other hand, it showed the phosphorylation of different Stat proteins. It was determined that cADSCs and mADSCs show the potential to differentiate into adipocytes, osteocytes, and chondrocytes. Furthermore, a difference in protein phosphorylation between undifferentiated cADSCs and mADSCs was identified.

  4. Activity of ethanol-stressed Oenococcus oeni cells: a flow cytometric approach

    NARCIS (Netherlands)

    Silveira, da M.G.; Abee, T.

    2009-01-01

    Aims: To study the effect of ethanol on Oenococcus oeni activity at the single cell level. Methods and Results: The active extrusion of the fluorescent probe carboxy fluorescein (cF) was used to assess the metabolic activity of ethanol-stressed O. oeni cells. Subsequent flow cytometric analysis

  5. Double fluorescent flow cytometric assessment of bacterial internalization and binding by epithelial cells

    NARCIS (Netherlands)

    de Boer, E. C.; Bevers, R. F.; Kurth, K. H.; Schamhart, D. H.

    1996-01-01

    This study describes a new flow cytometric method for assessment of phagocytosis of specific bacteria (bacillus Calmette-Guérin (BCG) and Escherichia coli) by bladder epithelial cells. The internalization assay consisted of labeling bacteria chemically with fluorescein isothiocyanate (FITC).

  6. Flow cytometric immunophenotyping of adult T-cell leukemia/lymphoma using CD3 gating.

    Science.gov (United States)

    Yokote, Taiji; Akioka, Toshikazu; Oka, Satoko; Hara, Satoshi; Kobayashi, Kichinosuke; Nakajima, Hideto; Yamano, Takeshi; Ikemoto, Toshiyuki; Shimizu, Akira; Tsuji, Motomu; Hanafusa, Toshiaki

    2005-08-01

    Adult T-cell leukemia/lymphoma (ATLL) is a lymphoproliferative neoplasm of helper T lymphocytes caused by human T-cell leukemia virus type-1 (HTLV-1). The disease was first described in Kyushu, in southwestern Japan, and most frequently occurs in endemic areas, such as Japan, the Caribbean basin, West Africa, Brazil, and northern Iran. ATLL is essentially a disease of adults, characterized clinically by generalized lymphadenopathy, hepatosplenomegaly, skin lesions, and hypercalcemia. The prognosis of most patients is quite poor, with a median survival time of only 13 months, even if multiagent combination chemotherapy is given. In the present study, flow cytometric immunophenotyping with CD3 gating was performed on 30 samples from 26 patients who had been given a diagnosis of ATLL. The records of these patients also were reviewed retrospectively. In 14 of the 30 samples, an abnormal CD3(low) T-cell population was distinguishable from the normal T-cell populations by flow cytometric analysis. Herein we report a novel strategy for flow cytometric immunophenotyping of ATLL facilitated by CD3(low) gating.

  7. Flow cytometric quantification of radiation responses of murine peritoneal cells

    International Nuclear Information System (INIS)

    Tokita, N.; Raju, M.R.

    1982-01-01

    Methods have been developed to distinguish subpopulations of murine peritoneal cells, and these were applied to the measurement of early changes in peritoneal cells after irradiation. The ratio of the two major subpopulations in the peritoneal fluid, lymphocytes and macrophages, was measured rapidly by means of cell volume distribution analysis as well as by hypotonic propidium iodide (PI) staining. After irradiation, dose and time dependent changes were noted in the cell volume distributions: a rapid loss of peritoneal lymphocytes, and an increase in the mean cell volume of macrophages. The hypotonic PI staining characteristics of the peritoneal cells showed two or three distinctive G 1 peaks. The ratio of the areas of these peaks was also found to be dependent of the radiation dose and the time after irradiation. These results demonstrate that these two parameters may be used to monitor changes induced by irradiation (biological dosimetry), and to sort different peritoneal subpopulations

  8. Discrimination of bromodeoxyuridine labelled and unlabelled mitotic cells in flow cytometric bromodeoxyuridine/DNA analysis

    DEFF Research Database (Denmark)

    Jensen, P O; Larsen, J K; Christensen, I J

    1994-01-01

    Bromodeoxyuridine (BrdUrd) labelled and unlabelled mitotic cells, respectively, can be discriminated from interphase cells using a new method, based on immunocytochemical staining of BrdUrd and flow cytometric four-parameter analysis of DNA content, BrdUrd incorporation, and forward and orthogonal...... light scatter. The method was optimized using the human leukemia cell lines HL-60 and K-562. Samples of 10(5) ethanol-fixed cells were treated with pepsin/HCl and stained as a nuclear suspension with anti-BrdUrd antibody, FITC-conjugated secondary antibody, and propidium iodide. Labelled mitoses could...

  9. Flow Cytometric Analysis of T, B, and NK Cells Antigens in Patients with Mycosis Fungoides

    Directory of Open Access Journals (Sweden)

    Serkan Yazıcı

    2015-01-01

    Full Text Available We retrospectively analyzed the clinicopathological correlation and prognostic value of cell surface antigens expressed by peripheral blood mononuclear cells in patients with mycosis fungoides (MF. 121 consecutive MF patients were included in this study. All patients had peripheral blood flow cytometry as part of their first visit. TNMB and histopathological staging of the cases were retrospectively performed in accordance with International Society for Cutaneous Lymphomas/European Organization of Research and Treatment of Cancer (ISCL/EORTC criteria at the time of flow cytometry sampling. To determine prognostic value of cell surface antigens, cases were divided into two groups as stable and progressive disease. 17 flow cytometric analyses of 17 parapsoriasis (PP and 11 analyses of 11 benign erythrodermic patients were included as control groups. Fluorescent labeled monoclonal antibodies were used to detect cell surface antigens: T cells (CD3+, CD4+, CD8+, TCRαβ+, TCRγδ+, CD7+, CD4+CD7+, CD4+CD7−, and CD71+, B cells (HLA-DR+, CD19+, and HLA-DR+CD19+, NKT cells (CD3+CD16+CD56+, and NK cells (CD3−CD16+CD56+. The mean value of all cell surface antigens was not statistically significant between parapsoriasis and MF groups. Along with an increase in cases of MF stage statistically significant difference was found between the mean values of cell surface antigens. Flow cytometric analysis of peripheral blood cell surface antigens in patients with mycosis fungoides may contribute to predicting disease stage and progression.

  10. A new one-platform flow cytometric method for residual cell counting in platelet concentrates.

    Science.gov (United States)

    Schmidt, Michael; Spengler, Hans-Peter; Lambrecht, Bernd; Hourfar, Michael K; Seifried, Erhard; Tonn, Torsten

    2009-12-01

    According to German regulations and guidelines, residual red blood cells (rRBCs) and residual white blood cells (rWBCs) must number fewer than 3 x 10(9) cells/unit and 1 x 10(6) cells/unit in platelet concentrates (PCs), respectively. Due to low levels of residual cells in final products, there is still a need for fast, reliable, and sensitive methods of automated detection of these cell types. In Part A, 21 PCs were spiked with predetermined numbers of red blood cells (RBCs) and white blood cells (WBCs). The linearity, precision, and accuracy of the BD Thrombo Count assay (BD Biosciences Europe) were tested and validated according to international guidelines. Finally in Part B, 100 PCs prepared from pooled buffy coats were tested by the BD Thrombo Count assay and compared with other methods, including Nageotte (rWBCs) and Neubauer (rRBCs) counting chambers and the flow cytometric BD LeucoCOUNT (Becton Dickinson) assay (rWBCs). The unspecific background of blank PC samples was fewer than 0.02 cells/microL for WBCs and fewer than 34 cells/microL for RBCs (mean, 21). Linear regression and precision analyses of spiked PC samples were determined for both WBCs (r(2) = 0.992; range, 0.6-6.0 WBCs/microL) and RBCs (r(2) = 0.999; 800-8000 RBCs/microL). No carryover of cells or drift in results was detected in the automated sample acquisition mode. Analysis according to statistical methods of Bland and Altman demonstrated a high correlation between BD Thrombo Count and the Neubauer manual counting chamber. This novel flow cytometric test is a quick and reliable single-tube assay that has been demonstrated as a potential alternative for the existing manual microscopic counting procedures that are both time-consuming and laborious.

  11. Dissociation of mono- and co-culture spheroids into single cells for subsequent flow cytometric analysis.

    Science.gov (United States)

    Grässer, Ute; Bubel, Monika; Sossong, Daniela; Oberringer, Martin; Pohlemann, Tim; Metzger, Wolfgang

    2018-03-01

    Spheroids are considered to reflect the natural organization of cells better than 2D cell cultures, but their analysis by flow cytometry requires dissociation into single cells. We established protocols for dissociation of mono- and co-culture spheroids consisting of human fibroblasts and human endothelial cells. Cell recovery rate and viability after dissociation were evaluated with hemocytometer and by flow cytometry. The diameter of cells and the amount of cell aggregates were quantified by Casy ® -technology and the cellular composition was analyzed by flow cytometry. Optimal dissociation conditions with low cell aggregation were determined by size, cultivation time and cellular composition of the spheroids. Smaller spheroids (10,000 cells) could be dissociated with Accutase ® , whereas larger spheroids (50,000 cells) required more stringent dissociation conditions. The size of the cells decreased with increasing cultivation time. Cell recovery rate was dependent upon cellular composition and spheroid size. The highest cell recovery rate was found for co-culture spheroids. The highest cell viability was detected for dissociated fibroblast spheroids. A quantitative analysis of the cellular composition of dissociated co-culture spheroids was possible. Spheroids can be successfully dissociated into singular cells for subsequent flow cytometric analysis. Dissociation conditions as well as cell recovery rate and cell viability depend on size, cultivation time and cellular composition of the spheroids. The observed decrease in cell size in spheroids over time might be responsible for the well-known time-dependent decrease in spheroid size. Copyright © 2017 Elsevier GmbH. All rights reserved.

  12. Improved flow cytometric assessment reveals distinct microvesicle (cell-derived microparticle signatures in joint diseases.

    Directory of Open Access Journals (Sweden)

    Bence György

    Full Text Available INTRODUCTION: Microvesicles (MVs, earlier referred to as microparticles, represent a major type of extracellular vesicles currently considered as novel biomarkers in various clinical settings such as autoimmune disorders. However, the analysis of MVs in body fluids has not been fully standardized yet, and there are numerous pitfalls that hinder the correct assessment of these structures. METHODS: In this study, we analyzed synovial fluid (SF samples of patients with osteoarthritis (OA, rheumatoid arthritis (RA and juvenile idiopathic arthritis (JIA. To assess factors that may confound MV detection in joint diseases, we used electron microscopy (EM, Nanoparticle Tracking Analysis (NTA and mass spectrometry (MS. For flow cytometry, a method commonly used for phenotyping and enumeration of MVs, we combined recent advances in the field, and used a novel approach of differential detergent lysis for the exclusion of MV-mimicking non-vesicular signals. RESULTS: EM and NTA showed that substantial amounts of particles other than MVs were present in SF samples. Beyond known MV-associated proteins, MS analysis also revealed abundant plasma- and immune complex-related proteins in MV preparations. Applying improved flow cytometric analysis, we demonstrate for the first time that CD3(+ and CD8(+ T-cell derived SF MVs are highly elevated in patients with RA compared to OA patients (p=0.027 and p=0.009, respectively, after Bonferroni corrections. In JIA, we identified reduced numbers of B cell-derived MVs (p=0.009, after Bonferroni correction. CONCLUSIONS: Our results suggest that improved flow cytometric assessment of MVs facilitates the detection of previously unrecognized disease-associated vesicular signatures.

  13. Differentiation of HL-60 promyelocytic leukemia cells monitored by flow cytometric measurement of nitro blue tetrazolium (NBT) reduction.

    Science.gov (United States)

    Blair, O C; Carbone, R; Sartorelli, A C

    1985-01-01

    Reduction of nitro blue tetrazolium (NBT) to insoluble blue formazan granules occurs during the stimulus-induced respiratory burst of mature granulocytes and is routinely used as an indicator of the extent of granulocytic differentiation of HL-60 acute promyelocytic leukemia cells. In the present study, the differentiation of HL-60 leukemia cells induced by dimethylsulfoxide (DMSO) or retinoic acid was monitored by flow cytometric (FCM) measurement of forward and 90 degree light scatter of NBT treated cells. Two-parameter correlated analysis permitted a distinction between cells with increased forward and decreased 90 degree light scatter (NBT-), and cells with decreased forward and increased 90 degree light scatter (NBT+). Fixation of NBT treated cells with 1% paraformaldehyde facilitated flow cytometric analysis, and allowed differences in NBT reduction to be quantitated. DMSO-induced cells expressed an all-or-none reduction of NBT to formazan, compared with retinoic acid treated cells that exhibited a graded response. Three parameter flow cytometric analysis of HL-60 leukemia cells stained with propidium iodide in combination with NBT allowed the determination of the cell cycle distribution of NBT-treated cells.

  14. A flow cytometric method for characterization of circulating cell-derived microparticles in plasma

    Directory of Open Access Journals (Sweden)

    Morten Hjuler Nielsen

    2014-02-01

    Full Text Available Background and aim: Previous studies on circulating microparticles (MPs indicate that the majority of MPs are of a size below the detection limit of most standard flow cytometers. The objective of the present study was to establish a method to analyze MP subpopulations above the threshold of detection of a new generation BD FACSAria™ III digital flow cytometer. Methods: We analyzed MP subpopulations in plasma from 24 healthy individuals (9 males and 15 females. MPs were identified according to their size (<1.0-µm, by Lactadherin-FITC labelling, and by exposure of cell-specific markers. The sensitivity of the flow cytometer was tested against that of a previous-generation instrument FC500. Reproducibility of the FACSAria and our set-up was investigated, and the percentage of phosphatidylserine (PS exposing MPs binding Lactadherin was determined. Results: By using a flow cytometric approach we identified and quantitated MPs derived from platelets, monocytes, erythrocytes and endothelial cells. In addition, levels of tissue factor-positive MPs were determined. The FACSAria demonstrated improved sensitivity and increased MP detection range compared to the FC500 instrument. The reproducibility of PS+PMP and PS+MP measurements was 11.7 and 23.2%, respectively. When expressed as a percentage of total MPs, the PS-positive MP population represented 15.1±5.5%, and PS-positive MPs were significantly increased in men. Conclusion: We have established a method to measure MPs above the detection limit of a new generation flow cytometer and derived from a number of cell-types in a healthy population of men and women.

  15. A novel rapid and reproducible flow cytometric method for optimization of transfection efficiency in cells.

    Science.gov (United States)

    Homann, Stefanie; Hofmann, Christian; Gorin, Aleksandr M; Nguyen, Huy Cong Xuan; Huynh, Diana; Hamid, Phillip; Maithel, Neil; Yacoubian, Vahe; Mu, Wenli; Kossyvakis, Athanasios; Sen Roy, Shubhendu; Yang, Otto Orlean; Kelesidis, Theodoros

    2017-01-01

    Transfection is one of the most frequently used techniques in molecular biology that is also applicable for gene therapy studies in humans. One of the biggest challenges to investigate the protein function and interaction in gene therapy studies is to have reliable monospecific detection reagents, particularly antibodies, for all human gene products. Thus, a reliable method that can optimize transfection efficiency based on not only expression of the target protein of interest but also the uptake of the nucleic acid plasmid, can be an important tool in molecular biology. Here, we present a simple, rapid and robust flow cytometric method that can be used as a tool to optimize transfection efficiency at the single cell level while overcoming limitations of prior established methods that quantify transfection efficiency. By using optimized ratios of transfection reagent and a nucleic acid (DNA or RNA) vector directly labeled with a fluorochrome, this method can be used as a tool to simultaneously quantify cellular toxicity of different transfection reagents, the amount of nucleic acid plasmid that cells have taken up during transfection as well as the amount of the encoded expressed protein. Finally, we demonstrate that this method is reproducible, can be standardized and can reliably and rapidly quantify transfection efficiency, reducing assay costs and increasing throughput while increasing data robustness.

  16. A Flow Cytometric Analysis of Vitreous Inflammatory Cells in Patients with Proliferative Diabetic Retinopathy

    Directory of Open Access Journals (Sweden)

    Mojca Urbančič

    2013-01-01

    Full Text Available The purpose of this study was to investigate inflammatory cells in vitreous from patients with proliferative diabetic retinopathy (PDR using flow cytometric analysis. Twenty-eight patients with PDR requiring vitrectomy because of macular traction or tractional retinal detachment were enrolled in the study (n=28, and 6 patients with macular hole (MH formed the control group. Samples of vitreous and peripheral venous blood were obtained at the beginning of vitrectomy. T lymphocytes were found in vitreous from patients with PDR, and CD4/CD8 ratio was higher in vitreous (median 4.3 compared to blood (median 1.9; P=0.003. No B lymphocytes were detected in vitreous. The percentage of histiocytes/macrophages was significantly higher in vitreous (median 62.1 in comparison with blood (median 5.5; P<0.0001. No lymphocytes were detected in vitreous of the control group. There were more T lymphocytes in vitreous from patients with active PDR. No association between cells in the vitreous and visual acuity improvement after surgery was found. In conclusion, T lymphocytes are found in vitreous from patients with PDR and reflect the activity of PDR but do not seem to predict visual prognosis. Higher CD4/CD8 ratio in vitreous compared to blood from patients with PDR is consistent with local inflammatory response in PDR.

  17. Flow cytometric probing of mitochondrial function in equine peripheral blood mononuclear cells

    Directory of Open Access Journals (Sweden)

    Coignoul Freddy

    2007-09-01

    Full Text Available Abstract Background The morphopathological picture of a subset of equine myopathies is compatible with a primary mitochondrial disease, but functional confirmation in vivo is still pending. The cationic dye JC-1 exhibits potential-dependent accumulation in mitochondria that is detectable by a fluorescence shift from green to orange. As a consequence, mitochondrial membrane potential can be optically measured by the orange/green fluorescence intensity ratio. A flow cytometric standardized analytic procedure of the mitochondrial function of equine peripheral blood mononuclear cells is proposed along with a critical appraisal of the crucial questions of technical aspects, reproducibility, effect of time elapsed between blood sampling and laboratory processing and reference values. Results The JC-1-associated fluorescence orange and green values and their ratio were proved to be stable over time, independent of age and sex and hypersensitive to intoxication with a mitochondrial potential dissipator. Unless time elapsed between blood sampling and laboratory processing does not exceed 5 hours, the values retrieved remain stable. Reference values for clinically normal horses are given. Conclusion Whenever a quantitative measurement of mitochondrial function in a horse is desired, blood samples should be taken in sodium citrate tubes and kept at room temperature for a maximum of 5 hours before the laboratory procedure detailed here is started. The hope is that this new test may help in confirming, studying and preventing equine myopathies that are currently imputed to mitochondrial dysfunction.

  18. Development of a flow cytometric assay to quantify lymphocyte adhesion to cytokine-stimulated human endothelial and biliary epithelial cells.

    Science.gov (United States)

    Korlipara, L V; Leon, M P; Rix, D A; Douglas, M S; Gibbs, P; Bassendine, M F; Kirby, J A

    1996-05-27

    The adhesive interaction between T lymphocytes and parenchymal cells is of importance for many processes of the cellular immune response. This adhesion is regulated by the activation status of the T cell and by cytokines in the microenvironment which can alter adhesion molecule expression by endothelial and epithelial cells. In this study results from an isotopic adhesion assay were compared with those from a flow cytometric assay in order to determine which was most appropriate for the investigation of lymphocyte adhesion to human umbilical vein endothelial cells (HUVEC) and intrahepatic biliary epithelial cells (HIBEC). Treatment of both these cell types with the proinflammatory cytokines interferon-gamma (IFN-gamma) or tumour necrosis factor-alpha (TNF-alpha) significantly upregulated expression of intercellular adhesion molecule-1 (ICAM-1). Treatment with TNF-alpha also induced endothelial cells to express vascular cell adhesion molecule-1 (VCAM-1). The isotopic assay demonstrated increased adhesion of lymphoblasts to HUVEC which had been stimulated with cytokines for 15 h but failed to detect major changes in adhesion following 72 h of cytokine treatment of HUVEC or HIBEC. However, the flow cytometric assay reproducibly demonstrated increased adhesion following cytokine treatment for both these time periods; these increases corresponded with the changes in adhesion molecule expression by cytokine-stimulated HUVEC and HIBEC targets. The differences in apparent adhesion measured by the two assays after cytokine stimulation for 72 h may be explained by cytokine-induced changes in the morphology and confluency of cultured cells. Results of the isotopic assay are proportional to the total number of lymphoid cells bound by the cultured target cells and will be distorted by changes in effective target cell area. The flow cytometric assay measures the mean number of lymphoid cells bound by each target cell and is independent of the total binding area. It is concluded

  19. Flow cytometric analysis of expression of interleukin-2 receptor beta chain (p70-75) on various leukemic cells

    International Nuclear Information System (INIS)

    Hoshino, S.; Oshimi, K.; Tsudo, M.; Miyasaka, M.; Teramura, M.; Masuda, M.; Motoji, T.; Mizoguchi, H.

    1990-01-01

    We analyzed the expression of the interleukin-2 receptor (IL-2R) beta chain (p70-75) on various leukemic cells from 44 patients by flow cytometric analysis using the IL-2R beta chain-specific monoclonal antibody, designated Mik-beta 1. Flow cytometric analysis demonstrated the expression of the IL-2R beta chain on granular lymphocytes (GLs) from all eight patients with granular lymphocyte proliferative disorders (GLPDs), on adult T-cell leukemia (ATL) cells from all three patients with ATL, and on T-cell acute lymphoblastic leukemia (T-ALL) cells from one of three patients with T-ALL. Although GLs from all the GLPD patients expressed the IL-2R beta chain alone and not the IL-2R alpha chain (Tac-antigen: p55), ATL and T-ALL cells expressing the beta chain coexpressed the alpha chain. In two of seven patients with common ALL (cALL) and in both patients with B-cell chronic lymphocytic leukemia, the leukemic cells expressed the alpha chain alone. Neither the alpha chain nor the beta chain was expressed on leukemic cells from the remaining 28 patients, including all 18 patients with acute nonlymphocytic leukemia, five of seven patients with cALL, all three patients with multiple myeloma, and two of three patients with T-ALL. These results indicate that three different forms of IL-2R chain expression exist on leukemic cells: the alpha chain alone; the beta chain alone; and both the alpha and beta chains. To examine whether the results obtained by flow cytometric analysis actually reflect functional aspects of the expressed IL-2Rs, we studied the specific binding of 125I-labeled IL-2 (125I-IL-2) to leukemic cells in 18 of the 44 patients. In addition, we performed 125I-IL-2 crosslinking studies in seven patients. The results of IL-2R expression of both 125I-IL-2 binding assay and crosslinking studies were in agreement with those obtained by flow cytometric analysis

  20. A Protocol for the Comprehensive Flow Cytometric Analysis of Immune Cells in Normal and Inflamed Murine Non-Lymphoid Tissues

    Science.gov (United States)

    Yu, Yen-Rei A.; O’Koren, Emily G.; Hotten, Danielle F.; Kan, Matthew J.; Kopin, David; Nelson, Erik R.; Que, Loretta; Gunn, Michael D.

    2016-01-01

    Flow cytometry is used extensively to examine immune cells in non-lymphoid tissues. However, a method of flow cytometric analysis that is both comprehensive and widely applicable has not been described. We developed a protocol for the flow cytometric analysis of non-lymphoid tissues, including methods of tissue preparation, a 10-fluorochrome panel for cell staining, and a standardized gating strategy, that allows the simultaneous identification and quantification of all major immune cell types in a variety of normal and inflamed non-lymphoid tissues. We demonstrate that our basic protocol minimizes cell loss, reliably distinguishes macrophages from dendritic cells (DC), and identifies all major granulocytic and mononuclear phagocytic cell types. This protocol is able to accurately quantify 11 distinct immune cell types, including T cells, B cells, NK cells, neutrophils, eosinophils, inflammatory monocytes, resident monocytes, alveolar macrophages, resident/interstitial macrophages, CD11b- DC, and CD11b+ DC, in normal lung, heart, liver, kidney, intestine, skin, eyes, and mammary gland. We also characterized the expression patterns of several commonly used myeloid and macrophage markers. This basic protocol can be expanded to identify additional cell types such as mast cells, basophils, and plasmacytoid DC, or perform detailed phenotyping of specific cell types. In examining models of primary and metastatic mammary tumors, this protocol allowed the identification of several distinct tumor associated macrophage phenotypes, the appearance of which was highly specific to individual tumor cell lines. This protocol provides a valuable tool to examine immune cell repertoires and follow immune responses in a wide variety of tissues and experimental conditions. PMID:26938654

  1. A Protocol for the Comprehensive Flow Cytometric Analysis of Immune Cells in Normal and Inflamed Murine Non-Lymphoid Tissues.

    Directory of Open Access Journals (Sweden)

    Yen-Rei A Yu

    Full Text Available Flow cytometry is used extensively to examine immune cells in non-lymphoid tissues. However, a method of flow cytometric analysis that is both comprehensive and widely applicable has not been described. We developed a protocol for the flow cytometric analysis of non-lymphoid tissues, including methods of tissue preparation, a 10-fluorochrome panel for cell staining, and a standardized gating strategy, that allows the simultaneous identification and quantification of all major immune cell types in a variety of normal and inflamed non-lymphoid tissues. We demonstrate that our basic protocol minimizes cell loss, reliably distinguishes macrophages from dendritic cells (DC, and identifies all major granulocytic and mononuclear phagocytic cell types. This protocol is able to accurately quantify 11 distinct immune cell types, including T cells, B cells, NK cells, neutrophils, eosinophils, inflammatory monocytes, resident monocytes, alveolar macrophages, resident/interstitial macrophages, CD11b- DC, and CD11b+ DC, in normal lung, heart, liver, kidney, intestine, skin, eyes, and mammary gland. We also characterized the expression patterns of several commonly used myeloid and macrophage markers. This basic protocol can be expanded to identify additional cell types such as mast cells, basophils, and plasmacytoid DC, or perform detailed phenotyping of specific cell types. In examining models of primary and metastatic mammary tumors, this protocol allowed the identification of several distinct tumor associated macrophage phenotypes, the appearance of which was highly specific to individual tumor cell lines. This protocol provides a valuable tool to examine immune cell repertoires and follow immune responses in a wide variety of tissues and experimental conditions.

  2. Cell cycle flow cytometric analysis in the diagnosis and management of colorectal carcinoma.

    Science.gov (United States)

    Sampedro, A; Salas-Bustamante, A; López-Artimez, M; García-Muñíz, J L; Urdiales, G

    1999-08-01

    To establish prognostic models and protocols for individualized management in colorectal carcinoma patients based on both clinical and DNA flow cytometric parameters. Prospective study of 88 colon carcinoma patients with a minimum follow-up of 12 months, operated on with the intent to cure and not treated with radiotherapy or chemotherapy. All the cases were subjected to a clinical evaluation: age, sex, tumor localization and size, histologic grade, tumor stage, disease-free interval, survival and flow cytometric study (ploidy, DNA index and S-phase fraction [SPF]). From the total of 88 neoplasms studied, 56 (63.6%) were from males and 32 (36.4%) from females; 30 (34%) were located in the right side of the colon, 7 (8%) in the transverse colon and 51 (58%) in the left side of the colon. Eleven (12.5%) were stage I, 52 (59.1%) stage II and 25 (28%) stage III. Forty-two (47.7%) were diploid and 46 (52.3%) aneuploid. The S-phase mean was 14.6% (12% for diploids and 16.9% for aneuploids). During the follow-up period, 26.1% of diploid tumors recurred, whereas aneuploid tumors recurred in 36.9% (P < .05). SPF from diploid and aneuploid tumors was analyzed separately. Regarding relapse-free interval, the behavior of diploid tumors with a high SPF was similar to that of aneuploid ones. Two kinetic profiles were established, favorable (diploid tumors with low S phase) and unfavorable (diploid with high S phase and all aneuploid tumors), that had significant prognostic value for progression and survival and that allowed identification of patients at high risk of recurrence. We formulated a prognostic index according to SPF and tumor stage that has discriminatory capacity for biologic behavior in colorectal tumors.

  3. A flow cytometric assay for simultaneously measuring the ...

    African Journals Online (AJOL)

    This research objective was to exploit a novel method for measuring the proliferation, cytotoxicity of cytokine-induced killer (CIK) cells using carboxyfluorescein succinimidyl ester/proliferation index (CFSE/PI) and flow cytometric assay. As cells divide, CFSE is apportioned equally between the two daughter cells, leading to a ...

  4. Chemosensitivity of human small cell carcinoma of the lung detected by flow cytometric DNA analysis of drug-induced cell cycle perturbations in vitro

    DEFF Research Database (Denmark)

    Engelholm, S A; Spang-Thomsen, M; Vindeløv, L L

    1986-01-01

    A method based on detection of drug-induced cell cycle perturbation by flow cytometric DNA analysis has previously been described in Ehrlich ascites tumors as a way to estimate chemosensitivity. The method is extended to test human small-cell carcinoma of the lung. Three tumors with different...... sensitivities to melphalan in nude mice were used. Tumors were disaggregated by a combined mechanical and enzymatic method and thereafter have incubated with different doses of melphalan. After incubation the cells were plated in vitro on agar, and drug induced cell cycle changes were monitored by flow...

  5. A flow cytometric assay for simultaneously measuring the ...

    African Journals Online (AJOL)

    Jane

    2011-10-24

    Oct 24, 2011 ... This research objective was to exploit a novel method for measuring the proliferation, cytotoxicity of cytokine-induced killer (CIK) cells using carboxyfluorescein succinimidyl ester/proliferation index. (CFSE/PI) and flow cytometric assay. As cells divide, CFSE is apportioned equally between the two daughter ...

  6. A flow cytometric assay to quantify invasion of red blood cells by rodent Plasmodium parasites in vivo.

    Science.gov (United States)

    Lelliott, Patrick M; Lampkin, Shelley; McMorran, Brendan J; Foote, Simon J; Burgio, Gaetan

    2014-03-17

    Malaria treatments are becoming less effective due to the rapid spread of drug resistant parasites. Increased understanding of the host/parasite interaction is crucial in order to develop treatments that will be less prone to resistance. Parasite invasion of the red blood cell (RBC) is a critical aspect of the parasite life cycle and is, therefore, a promising target for the development of malaria treatments. Assays for analysing parasite invasion in vitro have been developed, but no equivalent assays exist for in vivo studies. This article describes a novel flow cytometric in vivo parasite invasion assay. Experiments were conducted with mice infected with erythrocytic stages of Plasmodium chabaudi adami strain DS. Exogenously labelled blood cells were transfused into infected mice at schizogony, and collected blood samples stained and analysed using flow cytometry to specifically detect and measure proportions of labelled RBC containing newly invaded parasites. A combination of antibodies (CD45 and CD71) and fluorescent dyes, Hoechst (DNA) and JC-1 (mitochondrial membrane potential), were used to differentiate parasitized RBCs from uninfected cells, RBCs containing Howell-Jolly bodies, leukocytes and RBC progenitors. Blood cells were treated ex vivo with proteases to examine the effects on in vivo parasite invasion. The staining and flow cytometry analysis method was accurate in determining the parasitaemia down to 0.013% with the limit of detection at 0.007%. Transfused labelled blood supported normal rates of parasite invasion. Protease-treated red cells resulted in 35% decrease in the rate of parasite invasion within 30 minutes of introduction into the bloodstream of infected mice. The invasion assay presented here is a versatile method for the study of in vivo red cell invasion efficiency of Plasmodium parasites in mice, and allows direct comparison of invasion in red cells derived from two different populations. The method also serves as an accurate

  7. Simple and easy method to evaluate uptake potential of nanoparticles in mammalian cells using a flow cytometric light scatter analysis.

    Science.gov (United States)

    Suzuki, Hiroshi; Toyooka, Tatsushi; Ibuki, Yuko

    2007-04-15

    Many classes of nanoparticles have been synthesized and widely applied, however, there is a serious lack of information concerning their effects on human health and the environment. Considering that their use will increase, accurate and cost-effective measurement techniques for characterizing "nanotoxicity" are required. One major toxicological concern is that nanoparticles are easily taken up in the human body. In this study, we developed a method of evaluating the uptake potential of nanosized particles using flow cytometric light scatter. Suspended titanium dioxide (TiO2) particles (5, 23, or 5000 nm) were added to Chinese hamster ovary cells. Observation by confocal laser scanning microscopy showed that the TiO2 particles easily moved to the cytoplasm of the cultured mammalian cells, not to the nucleus. The intensity of the side-scattered light revealed that the particles were taken up in the cells dose-, time-, and size-dependently. In addition, surface-coating of TiO2 particles changed the uptake into the cells, which was accurately reflected in the intensity of the side-scattered light. The uptake of other nanoparticles such as silver (Ag) and iron oxide (Fe3O4) also could be detected. This method could be used for the initial screening of the uptake potential of nanoparticles as an index of "nanotoxicity".

  8. Flow Cytometric Detection of PrPScin Neurons and Glial Cells from Prion-Infected Mouse Brains.

    Science.gov (United States)

    Yamasaki, Takeshi; Suzuki, Akio; Hasebe, Rie; Horiuchi, Motohiro

    2018-01-01

    In prion diseases, an abnormal isoform of prion protein (PrP Sc ) accumulates in neurons, astrocytes, and microglia in the brains of animals affected by prions. Detailed analyses of PrP Sc -positive neurons and glial cells are required to clarify their pathophysiological roles in the disease. Here, we report a novel method for the detection of PrP Sc in neurons and glial cells from the brains of prion-infected mice by flow cytometry using PrP Sc -specific staining with monoclonal antibody (MAb) 132. The combination of PrP Sc staining and immunolabeling of neural cell markers clearly distinguished neurons, astrocytes, and microglia that were positive for PrP Sc from those that were PrP Sc negative. The flow cytometric analysis of PrP Sc revealed the appearance of PrP Sc -positive neurons, astrocytes, and microglia at 60 days after intracerebral prion inoculation, suggesting the presence of PrP Sc in the glial cells, as well as in neurons, from an early stage of infection. Moreover, the kinetic analysis of PrP Sc revealed a continuous increase in the proportion of PrP Sc -positive cells for all cell types with disease progression. Finally, we applied this method to isolate neurons, astrocytes, and microglia positive for PrP Sc from a prion-infected mouse brain by florescence-activated cell sorting. The method described here enables comprehensive analyses specific to PrP Sc -positive neurons, astrocytes, and microglia that will contribute to the understanding of the pathophysiological roles of neurons and glial cells in PrP Sc -associated pathogenesis. IMPORTANCE Although formation of PrP Sc in neurons is associated closely with neurodegeneration in prion diseases, the mechanism of neurodegeneration is not understood completely. On the other hand, recent studies proposed the important roles of glial cells in PrP Sc -associated pathogenesis, such as the intracerebral spread of PrP Sc and clearance of PrP Sc from the brain. Despite the great need for detailed analyses

  9. Flow cytometric measurement of the metabolism of benzo [a] pyrene by mouse liver cells in culture

    International Nuclear Information System (INIS)

    Bartholomew, J.C.; Wade, C.G.; Dougherty, K.

    1984-01-01

    The metabolism of benzo[a]pyrene in individual cells was monitored by flow cytometry. The measurements are based on the alterations that occur in the fluorescence emission spectrum of benzo[a]pyrene when it is converted to various metabolities. Using present instrumentation the technique could easily detect 1 x 10/sup 6/ molecules per cells of benzo [a]pyrene and 1 x 10/sup 7/ molecules per cell of the diol epoxide. The analysis of C3H IOT 1/2 mouse fibroblasts growing in culture indicated that there was heterogeneity in the conversion of the parent compound into diol epoxide derivative suggesting that some variation in sensitivity to transformation by benzo[a]pyrene may be due to differences in cellular metabolism

  10. A flow cytometric method for characterization of circulating cell-derived microparticles in plasma.

    Science.gov (United States)

    Nielsen, Morten Hjuler; Beck-Nielsen, Henning; Andersen, Morten Nørgaard; Handberg, Aase

    2014-01-01

    Previous studies on circulating microparticles (MPs) indicate that the majority of MPs are of a size below the detection limit of most standard flow cytometers. The objective of the present study was to establish a method to analyze MP subpopulations above the threshold of detection of a new generation BD FACSAria™ III digital flow cytometer. We analyzed MP subpopulations in plasma from 24 healthy individuals (9 males and 15 females). MPs were identified according to their size (derived from platelets, monocytes, erythrocytes and endothelial cells. In addition, levels of tissue factor-positive MPs were determined. The FACSAria demonstrated improved sensitivity and increased MP detection range compared to the FC500 instrument. The reproducibility of PS+PMP and PS+MP measurements was 11.7 and 23.2%, respectively. When expressed as a percentage of total MPs, the PS-positive MP population represented 15.1±5.5%, and PS-positive MPs were significantly increased in men. We have established a method to measure MPs above the detection limit of a new generation flow cytometer and derived from a number of cell-types in a healthy population of men and women.

  11. Flow cytometric studies of the survival of cytochalasin-induced polyploidy in Chinese hamster ovary cells.

    Science.gov (United States)

    Court, J B; Burn, C; Moore, J L

    1990-05-01

    A method has been developed to estimate the post-irradiation survival of cytochalasin B-induced polyploidization of adherent Chinese hamster ovary cell using the flow cytometer. After exposure to radiation, surviving cells are allowed to become polyploid in the presence of cytochalasin, and are detached using trypsin, fixed by the addition of glutaraldehyde and stained using mithramycin. DNA content distributions are polymodal, and the absolute number of cells per culture in any given ploidy class is estimated by reference to a non-fluorescent bead internal standard, detected using forward scatter. Post-irradiation survival is defined as the ability to reach a given DNA content, and is reduced exponentially with dose. A bioassay to determine optimum cytochalasin concentrations can be derived from the relative size of the 2C (G0/G1) peak in the DNA content distribution. At culture densities greater than about 8 x 10(4) cell/cm2 the relative number of cells reaching at least 16C is reduced, but this inhibition is partially reversible by an increase in the medium glucose concentration, but not by the use of cytochalasin D or dihydro B.

  12. Optimization of flow cytometric detection and cell sorting of transgenic Plasmodium parasites using interchangeable optical filters.

    Science.gov (United States)

    Vorobjev, Ivan A; Buchholz, Kathrin; Prabhat, Prashant; Ketman, Kenneth; Egan, Elizabeth S; Marti, Matthias; Duraisingh, Manoj T; Barteneva, Natasha S

    2012-09-05

    Malaria remains a major cause of morbidity and mortality worldwide. Flow cytometry-based assays that take advantage of fluorescent protein (FP)-expressing malaria parasites have proven to be valuable tools for quantification and sorting of specific subpopulations of parasite-infected red blood cells. However, identification of rare subpopulations of parasites using green fluorescent protein (GFP) labelling is complicated by autofluorescence (AF) of red blood cells and low signal from transgenic parasites. It has been suggested that cell sorting yield could be improved by using filters that precisely match the emission spectrum of GFP. Detection of transgenic Plasmodium falciparum parasites expressing either tdTomato or GFP was performed using a flow cytometer with interchangeable optical filters. Parasitaemia was evaluated using different optical filters and, after optimization of optics, the GFP-expressing parasites were sorted and analysed by microscopy after cytospin preparation and by imaging cytometry. A new approach to evaluate filter performance in flow cytometry using two-dimensional dot blot was developed. By selecting optical filters with narrow bandpass (BP) and maximum position of filter emission close to GFP maximum emission in the FL1 channel (510/20, 512/20 and 517/20; dichroics 502LP and 466LP), AF was markedly decreased and signal-background improve dramatically. Sorting of GFP-expressing parasite populations in infected red blood cells at 90 or 95% purity with these filters resulted in 50-150% increased yield when compared to the standard filter set-up. The purity of the sorted population was confirmed using imaging cytometry and microscopy of cytospin preparations of sorted red blood cells infected with transgenic malaria parasites. Filter optimization is particularly important for applications where the FP signal and percentage of positive events are relatively low, such as analysis of parasite-infected samples with in the intention of gene

  13. Optimization of flow cytometric detection and cell sorting of transgenic Plasmodium parasites using interchangeable optical filters

    Directory of Open Access Journals (Sweden)

    Vorobjev Ivan A

    2012-09-01

    Full Text Available Abstract Background Malaria remains a major cause of morbidity and mortality worldwide. Flow cytometry-based assays that take advantage of fluorescent protein (FP-expressing malaria parasites have proven to be valuable tools for quantification and sorting of specific subpopulations of parasite-infected red blood cells. However, identification of rare subpopulations of parasites using green fluorescent protein (GFP labelling is complicated by autofluorescence (AF of red blood cells and low signal from transgenic parasites. It has been suggested that cell sorting yield could be improved by using filters that precisely match the emission spectrum of GFP. Methods Detection of transgenic Plasmodium falciparum parasites expressing either tdTomato or GFP was performed using a flow cytometer with interchangeable optical filters. Parasitaemia was evaluated using different optical filters and, after optimization of optics, the GFP-expressing parasites were sorted and analysed by microscopy after cytospin preparation and by imaging cytometry. Results A new approach to evaluate filter performance in flow cytometry using two-dimensional dot blot was developed. By selecting optical filters with narrow bandpass (BP and maximum position of filter emission close to GFP maximum emission in the FL1 channel (510/20, 512/20 and 517/20; dichroics 502LP and 466LP, AF was markedly decreased and signal-background improve dramatically. Sorting of GFP-expressing parasite populations in infected red blood cells at 90 or 95% purity with these filters resulted in 50-150% increased yield when compared to the standard filter set-up. The purity of the sorted population was confirmed using imaging cytometry and microscopy of cytospin preparations of sorted red blood cells infected with transgenic malaria parasites. Discussion Filter optimization is particularly important for applications where the FP signal and percentage of positive events are relatively low, such as analysis

  14. Multiparameter Flow Cytometric Assays to Quantify Effector and Regulatory T-Cell Function in Multiple Sclerosis.

    Science.gov (United States)

    Sinha, Sushmita; Crawford, Michael P; Ortega, Sterling B; Karandikar, Nitin J

    2015-01-01

    The immune system plays a major pathological and regulatory role in multiple sclerosis (MS) and, therefore, is a focus of extensive research. Animal models of MS have been crucial in understanding the pathological processes in MS and developing certain treatments, however, all crucial aspects of the human disease may not be appropriately modeled. With the exception of detecting oligoclonal bands and IgG synthesis in cerebrospinal fluids of MS patients, there has not been major progress in the development of immunologic tests that can be used for diagnosis of MS. Further, due to the lack of validated immune assays, routine monitoring of the immune system following therapy initiation is not a part of standard patient care in MS. This is critical since immunomodulatory therapies used for MS treatment are not benign and, more importantly, there is a considerable variation in clinical responses in MS patients initiating such therapies. Flow cytometry is a powerful tool that can be used for studying both the phenotype and function of immune cells. The studies described here will demonstrate how flow cytometry can be used to apply current knowledge about the MS immune system to develop a diagnostic laboratory test for the immunologic monitoring of this disease. Importantly, we will also show that the multiparameter flow cytometry based assay developed by us can also be implemented for the immunologic evaluation of therapeutic success in MS patients.

  15. Flow Cytometric Quantification of Peripheral Blood Cell β-Adrenergic Receptor Density and Urinary Endothelial Cell-Derived Microparticles in Pulmonary Arterial Hypertension.

    Directory of Open Access Journals (Sweden)

    Jonathan A Rose

    Full Text Available Pulmonary arterial hypertension (PAH is a heterogeneous disease characterized by severe angiogenic remodeling of the pulmonary artery wall and right ventricular hypertrophy. Thus, there is an increasing need for novel biomarkers to dissect disease heterogeneity, and predict treatment response. Although β-adrenergic receptor (βAR dysfunction is well documented in left heart disease while endothelial cell-derived microparticles (Ec-MPs are established biomarkers of angiogenic remodeling, methods for easy large clinical cohort analysis of these biomarkers are currently absent. Here we describe flow cytometric methods for quantification of βAR density on circulating white blood cells (WBC and Ec-MPs in urine samples that can be used as potential biomarkers of right heart failure in PAH. Biotinylated β-blocker alprenolol was synthesized and validated as a βAR specific probe that was combined with immunophenotyping to quantify βAR density in circulating WBC subsets. Ec-MPs obtained from urine samples were stained for annexin-V and CD144, and analyzed by a micro flow cytometer. Flow cytometric detection of alprenolol showed that βAR density was decreased in most WBC subsets in PAH samples compared to healthy controls. Ec-MPs in urine was increased in PAH compared to controls. Furthermore, there was a direct correlation between Ec-MPs and Tricuspid annular plane systolic excursion (TAPSE in PAH patients. Therefore, flow cytometric quantification of peripheral blood cell βAR density and urinary Ec-MPs may be useful as potential biomarkers of right ventricular function in PAH.

  16. Flow cytometric bacterial cell counts challenge conventional heterotrophic plate counts for routine microbiological drinking water monitoring.

    Science.gov (United States)

    Van Nevel, S; Koetzsch, S; Proctor, C R; Besmer, M D; Prest, E I; Vrouwenvelder, J S; Knezev, A; Boon, N; Hammes, F

    2017-04-15

    Drinking water utilities and researchers continue to rely on the century-old heterotrophic plate counts (HPC) method for routine assessment of general microbiological water quality. Bacterial cell counting with flow cytometry (FCM) is one of a number of alternative methods that challenge this status quo and provide an opportunity for improved water quality monitoring. After more than a decade of application in drinking water research, FCM methodology is optimised and established for routine application, supported by a considerable amount of data from multiple full-scale studies. Bacterial cell concentrations obtained by FCM enable quantification of the entire bacterial community instead of the minute fraction of cultivable bacteria detected with HPC (typically water samples per day, depending on the laboratory and selected staining procedure(s). Moreover, many studies have shown FCM total (TCC) and intact (ICC) cell concentrations to be reliable and robust process variables, responsive to changes in the bacterial abundance and relevant for characterising and monitoring drinking water treatment and distribution systems. The purpose of this critical review is to initiate a constructive discussion on whether FCM could replace HPC in routine water quality monitoring. We argue that FCM provides a faster, more descriptive and more representative quantification of bacterial abundance in drinking water. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Flow cytometric analysis of apoptosis in cryoconserved chicken primordial germ cells.

    Science.gov (United States)

    Sawicka, Dorota; Chojnacka-Puchta, Luiza; Zielinski, Marcin; Plucienniczak, Grazyna; Plucienniczak, Andrzej; Bednarczyk, Marek

    2015-03-01

    Our research aimed to compare the effects of four cryoprotectants and four slow freezing programs on the viability and apoptosis of primordial germ cells (PGCs) in vitro. PGCs were collected from chicken embryonic blood at Hamburger and Hamilton (HH) stages 14-16 and purified by Percoll density gradient centrifugation and then subjected to cryopreservation. We applied microscopy to determine the survival of PGCs after trypan blue staining and flow cytometry to examine apoptosis and viability after annexin V kit staining. We also examined the functionality of cryopreserved PGCs in vivo. Significant differences in viability of PGCs determined via microscopy and flow cytometry were observed. The most unfavorable combination for slow freezing PGCs was program 3 and MIX H (10% DMSO and 5% glycerol in Hank's solution supplemented with 10% FBS) as the cryoprotectant (48.43 and 15.37% live and early apoptotic PGCs, respectively). The highest average percentage of live PGCs (93.1%) and the lowest percentage of early apoptotic PGCs (6.5%) were achieved by slow freezing PGCs in the presence of DMSO F (10% DMSO in FBS) via program 1. Therefore, this method was chosen for the in vivo test. Cryopreserved (group 1) and freshly isolated (group 2) PGCs were transfectedwith a pEGFP-N1 plasmid, cultured under antibiotic selection, and then injected into 3-day-old embryos. After 5 days of incubation, we identified the EGFP marker gene in the gonads of 40 and 45% of recipients in groups 1 and 2, respectively. This is the first study to apply flow cytometry to examine the apoptosis and viability of cryopreserved PGCs. The in vitro and in vivo findings showed that the developed PGC cryoconservation method, depending on slow freezing at the rate of 2°C/min (program 1) in the presence of 10% DMSO F, is an improvement over previous cryoconservation methods and may be a useful tool for the ex situ strategy of poultry biodiversity preservation.

  18. Flow cytometric comparison of the effects of trialkyltins on the murine erythroleukemic cell.

    Science.gov (United States)

    Zucker, R M; Elstein, K H; Easterling, R E; Massaro, E J

    1989-10-02

    Cellular effects of exposure to tributyltin (TBT), triethyltin (TET), or trimethyltin (TMT) were investigated by flow cytometry employing the murine erythroleukemic cell (MELC) as a model cellular system. Cell viability was investigated by the carboxyfluorescein diacetate (CFDA) uptake/propidium iodide (PI) exclusion method: above a critical concentration (exposure for 4 h), which was specific for each of the trialkyltin compounds, the cell becomes permeable to PI, indicating loss of viability. Cellular CF fluorescence (derived from intracellular hydrolysis of CFDA) increased as a function of alkyltin concentration below the critical concentration and decreased as viability decreased above the critical concentration. Relative membrane potential, monitored with a cyanine dye (DiOC6), correlated with viability (PI exclusion), remaining essentially unaltered below the critical concentration and decreasing above it. At/above 1 microM TBT, 5 microM TET, or 100 microM TMT, the cell cycle was blocked in the G2/M phase. The 90 degrees light scatter (a measure of refractive index), axial light loss (a measure of volume), and fluorescein isothiocyanate (FITC) fluorescence (a measure of protein content) of nuclei isolated from trialkyltin-treated MELC by detergent treatment, increased as a function of organotin dose. Fluorescence and interference microscopy revealed increased quantities of residual cytoplasmic tags adherent to the nuclei as a function of organotin dose, apparently resulting from increased cytoplasmic resistance to detergent-mediated solubilization. The effects of the trialkyltins correlated with their lipophilicity (octanol/water coefficient). These data support the hypothesis that fixation (protein denaturation, cross-linking, etc.) is an important mode of organotin cytotoxicity.

  19. A flow cytometric technique for quantification and differentiation of bacteria in bulk tank milk

    DEFF Research Database (Denmark)

    Holm, C.; Mathiasen, T.; Jespersen, Lene

    2004-01-01

    AIMS: The present study describes a flow cytometric technique for quantification and differentiation of bacteria in bulk tank milk according to the main cause of elevated counts. METHODS AND RESULTS: A total of 75 Danish bulk tank milk samples exceeding the grading level of 3.0 x 10(4) CFU ml(-1...... parameters were as follows: staining with Oregon Green conjugated wheat germ agglutinin that binds to the cell wall of bacteria, staining with hexidium iodide that binds to all bacterial DNA, the flow cytometric forward scatter and the flow cytometric side scatter. Three regions in the flow cytometric plot...

  20. Flow cytometric bacterial cell counts challenge conventional heterotrophic plate counts for routine microbiological drinking water monitoring

    KAUST Repository

    Van Nevel, S.

    2017-02-08

    Drinking water utilities and researchers continue to rely on the century-old heterotrophic plate counts (HPC) method for routine assessment of general microbiological water quality. Bacterial cell counting with flow cytometry (FCM) is one of a number of alternative methods that challenge this status quo and provide an opportunity for improved water quality monitoring. After more than a decade of application in drinking water research, FCM methodology is optimised and established for routine application, supported by a considerable amount of data from multiple full-scale studies. Bacterial cell concentrations obtained by FCM enable quantification of the entire bacterial community instead of the minute fraction of cultivable bacteria detected with HPC (typically < 1% of all bacteria). FCM measurements are reproducible with relative standard deviations below 3% and can be available within 15 min of samples arriving in the laboratory. High throughput sample processing and complete automation are feasible and FCM analysis is arguably less expensive than HPC when measuring more than 15 water samples per day, depending on the laboratory and selected staining procedure(s). Moreover, many studies have shown FCM total (TCC) and intact (ICC) cell concentrations to be reliable and robust process variables, responsive to changes in the bacterial abundance and relevant for characterising and monitoring drinking water treatment and distribution systems. The purpose of this critical review is to initiate a constructive discussion on whether FCM could replace HPC in routine water quality monitoring. We argue that FCM provides a faster, more descriptive and more representative quantification of bacterial abundance in drinking water.

  1. Flow cytometric cell sorting and in vitro pre-osteoinduction are not requirements for in vivo bone formation by human adipose-derived stromal cells.

    Science.gov (United States)

    Liu, Yunsong; Zhao, Yan; Zhang, Xiao; Chen, Tong; Zhao, Xianghui; Ma, Gui-e; Zhou, Yongsheng

    2013-01-01

    Human adipose-derived stromal cells (hASCs) are a promising cell source for bone tissue engineering. However, before the clinical application of hASCs for the treatment of bone defects, key questions require answers, including whether pre-osteoinduction (OI) and flow cytometric cell purification are indispensible steps for in vivo bone formation by hASCs. In this study, hASCs were purified by flow cytometric cell sorting (FCCS). The osteogenic capabilities of hASCs and purified hASCs with or without pre-osteoinduction were examined through in vitro and in vivo experiments. We found that pre-OI enhanced the in vitro osteogenic capacity of hASCs. However, 8 weeks after in vivo implantation, there were no significant differences between hASCs and hASCs that had undergone OI (hASCs+OI) or between purified hASCs and purified hASCs+OI (P>0.05). Interestingly, we also found that purified hASCs had an osteogenic potential similar to that of unpurified hASCs in vitro and in vivo. These results suggest that FCCS and in vitro pre-OI are not requirements for in vivo bone formation by hASCs.

  2. Flow cytometric cell sorting and in vitro pre-osteoinduction are not requirements for in vivo bone formation by human adipose-derived stromal cells.

    Directory of Open Access Journals (Sweden)

    Yunsong Liu

    Full Text Available Human adipose-derived stromal cells (hASCs are a promising cell source for bone tissue engineering. However, before the clinical application of hASCs for the treatment of bone defects, key questions require answers, including whether pre-osteoinduction (OI and flow cytometric cell purification are indispensible steps for in vivo bone formation by hASCs. In this study, hASCs were purified by flow cytometric cell sorting (FCCS. The osteogenic capabilities of hASCs and purified hASCs with or without pre-osteoinduction were examined through in vitro and in vivo experiments. We found that pre-OI enhanced the in vitro osteogenic capacity of hASCs. However, 8 weeks after in vivo implantation, there were no significant differences between hASCs and hASCs that had undergone OI (hASCs+OI or between purified hASCs and purified hASCs+OI (P>0.05. Interestingly, we also found that purified hASCs had an osteogenic potential similar to that of unpurified hASCs in vitro and in vivo. These results suggest that FCCS and in vitro pre-OI are not requirements for in vivo bone formation by hASCs.

  3. A flow cytometric method for characterization of circulating cell-derived microparticles in plasma

    DEFF Research Database (Denmark)

    Nielsen, Morten Hjuler; Beck-Nielsen, Henning; Andersen, Morten Nørgaard

    2014-01-01

    BACKGROUND AND AIM: Previous studies on circulating microparticles (MPs) indicate that the majority of MPs are of a size below the detection limit of most standard flow cytometers. The objective of the present study was to establish a method to analyze MP subpopulations above the threshold...... of detection of a new generation BD FACSAria™ III digital flow cytometer. METHODS: We analyzed MP subpopulations in plasma from 24 healthy individuals (9 males and 15 females). MPs were identified according to their size (

  4. Flow cytometric assay detecting cytotoxicity against human endogenous retrovirus antigens expressed on cultured multiple sclerosis cells

    DEFF Research Database (Denmark)

    Møller-Larsen, A; Brudek, T; Petersen, T

    2013-01-01

    expressing increased amounts of human endogenous retrovirus antigens. MS patients also have increased antibody levels to these antigens. The target cells are spontaneously growing peripheral blood mononuclear cells (PBMCs) of B cell lineage, expressing human endogenous retrovirus HERV epitopes...... on their surface. Polyclonal antibodies against defined peptides in the Env- and Gag-regions of the HERVs were raised in rabbits and used in antibody-dependent cell-mediated cytotoxicity (ADCC) -assays. Rituximab® (Roche), a chimeric monoclonal antibody against CD20 expressed primarily on B cells, was used...

  5. Flow-cytometric measurements of somatic cell mutations in Thorotrast patients

    International Nuclear Information System (INIS)

    Umeki, Shigeko; Kyoizumi, Seishi; Kusunoki, Yoichiro; Nakamura, Nori; Sasaki, Masao; Mori, Takesaburo; Ishikawa, Yuichi; Cologne, J.B.; Akiyama, Mitoshi.

    1992-10-01

    Exposure to ionizing radiation is a well-recognized risk factor for cancer development. Because ionizing radiation can induce mutations, an accurate way of measuring somatic mutation frequencies could be a useful tool for evaluating cancer risk. In the present study, we have examined in vivo somatic mutation frequencies at the erythrocyte glycophorin A and T-cell receptor loci in 18 Thorotrast patients. These persons have been continuously irradiated with alpha particles emitted from the internal deposition of thorium dioxide and thus have increased risks of certain malignant tumors. When compared with controls, the Thorotrast patients showed a significantly higher frequency of mutants at the lymphocyte T-cell receptor loci but not at the erythrocyte glycophorin A loci. (author)

  6. Molecular pathways of early CD105-positive erythroid cells as compared with CD34-positive common precursor cells by flow cytometric cell-sorting and gene expression profiling

    International Nuclear Information System (INIS)

    Machherndl-Spandl, S; Suessner, S; Danzer, M; Proell, J; Gabriel, C; Lauf, J; Sylie, R; Klein, H-U; Béné, M C; Weltermann, A; Bettelheim, P

    2013-01-01

    Special attention has recently been drawn to the molecular network of different genes that are responsible for the development of erythroid cells. The aim of the present study was to establish in detail the immunophenotype of early erythroid cells and to compare the gene expression profile of freshly isolated early erythroid precursors with that of the CD34-positive (CD34 + ) compartment. Multiparameter flow cytometric analyses of human bone marrow mononuclear cell fractions (n=20) defined three distinct early erythroid stages. The gene expression profile of sorted early erythroid cells was analyzed by Affymetrix array technology. For 4524 genes, a differential regulation was found in CD105-positive erythroid cells as compared with the CD34 + progenitor compartment (2362 upregulated genes). A highly significant difference was observed in the expression level of genes involved in transcription, heme synthesis, iron and mitochondrial metabolism and transforming growth factor-β signaling. A comparison with recently published data showed over 1000 genes that as yet have not been reported to be upregulated in the early erythroid lineage. The gene expression level within distinct pathways could be illustrated directly by applying the Ingenuity software program. The results of gene expression analyses can be seen at the Gene Expression Omnibus repository

  7. Automated High-Dimensional Flow Cytometric Data Analysis

    Science.gov (United States)

    Pyne, Saumyadipta; Hu, Xinli; Wang, Kui; Rossin, Elizabeth; Lin, Tsung-I.; Maier, Lisa; Baecher-Allan, Clare; McLachlan, Geoffrey; Tamayo, Pablo; Hafler, David; de Jager, Philip; Mesirov, Jill

    Flow cytometry is widely used for single cell interrogation of surface and intracellular protein expression by measuring fluorescence intensity of fluorophore-conjugated reagents. We focus on the recently developed procedure of Pyne et al. (2009, Proceedings of the National Academy of Sciences USA 106, 8519-8524) for automated high- dimensional flow cytometric analysis called FLAME (FLow analysis with Automated Multivariate Estimation). It introduced novel finite mixture models of heavy-tailed and asymmetric distributions to identify and model cell populations in a flow cytometric sample. This approach robustly addresses the complexities of flow data without the need for transformation or projection to lower dimensions. It also addresses the critical task of matching cell populations across samples that enables downstream analysis. It thus facilitates application of flow cytometry to new biological and clinical problems. To facilitate pipelining with standard bioinformatic applications such as high-dimensional visualization, subject classification or outcome prediction, FLAME has been incorporated with the GenePattern package of the Broad Institute. Thereby analysis of flow data can be approached similarly as other genomic platforms. We also consider some new work that proposes a rigorous and robust solution to the registration problem by a multi-level approach that allows us to model and register cell populations simultaneously across a cohort of high-dimensional flow samples. This new approach is called JCM (Joint Clustering and Matching). It enables direct and rigorous comparisons across different time points or phenotypes in a complex biological study as well as for classification of new patient samples in a more clinical setting.

  8. Uncovering Aberrant Mutant PKA Function with Flow Cytometric FRET

    Directory of Open Access Journals (Sweden)

    Shin-Rong Lee

    2016-03-01

    Full Text Available Biology has been revolutionized by tools that allow the detection and characterization of protein-protein interactions (PPIs. Förster resonance energy transfer (FRET-based methods have become particularly attractive as they allow quantitative studies of PPIs within the convenient and relevant context of living cells. We describe here an approach that allows the rapid construction of live-cell FRET-based binding curves using a commercially available flow cytometer. We illustrate a simple method for absolutely calibrating the cytometer, validating our binding assay against the gold standard isothermal calorimetry (ITC, and using flow cytometric FRET to uncover the structural and functional effects of the Cushing-syndrome-causing mutation (L206R on PKA’s catalytic subunit. We discover that this mutation not only differentially affects PKAcat’s binding to its multiple partners but also impacts its rate of catalysis. These findings improve our mechanistic understanding of this disease-causing mutation, while illustrating the simplicity, general applicability, and power of flow cytometric FRET.

  9. Stereologic, histopathologic, flow cytometric, and clinical parameters in the prognostic evaluation of 74 patients with intraoral squamous cell carcinomas

    DEFF Research Database (Denmark)

    Bundgaard, T; Sørensen, Flemming Brandt; Gaihede, M

    1992-01-01

    BACKGROUND AND METHODS: A consecutive series of all 78 incident cases of intraoral squamous cell carcinoma occurring during a 2-year period in a population of 1.4 million inhabitants were evaluated by histologic score (the modified classification of Jacobsson et al.), flow cytometry, stereology, ...

  10. The cytometric future: it ain't necessarily flow!

    Science.gov (United States)

    Shapiro, Howard M

    2011-01-01

    Initial approaches to cytometry for classifying and characterizing cells were based on microscopy; it was necessary to collect relatively high-resolution images of cells because only a few specific reagents usable for cell identification were available. Although flow cytometry, now the dominant cytometric technology, typically utilizes lenses similar to microscope lenses for light collection, improved, more quantitative reagents allow the necessary information to be acquired in the form of whole-cell measurements of the intensities of light transmission, scattering, and/or fluorescence.Much of the cost and complexity of both automated microscopes and flow cytometers arises from the necessity for them to measure one cell at a time. Recent developments in digital camera technology now offer an alternative in which one or more low-magnification, low-resolution images are made of a wide field containing many cells, using inexpensive light-emitting diodes (LEDs) for illumination. Minimalist widefield imaging cytometers can provide a smaller, less complex, and substantially less expensive alternative to flow cytometry, critical in systems intended for in resource-poor areas. Minimalism is, likewise, a good philosophy in developing instrumentation and methodology for both clinical and large-scale research use; it simplifies quality assurance and compliance with regulatory requirements, as well as reduces capital outlays, material costs, and personnel training requirements. Also, importantly, it yields "greener" technology.

  11. Flow cytometric assessment of chicken T cell-mediated immune responses after Newcastle disease virus vaccination and challenge

    DEFF Research Database (Denmark)

    Dalgaard, T. S.; Norup, L. R.; Pedersen, A.R.

    2010-01-01

    . Despite a delayed NDV-specific antibody response to vaccination, L133 appeared to be better protected than L130 in the subsequent infection challenge as determined by the presence of viral genomes. Peripheral blood was analyzed by flow cytometry and responses in vaccinated/challenged birds were studied...... by 5-color immunophenotyping as well as by measuring the proliferative capacity of NDV-specific T cells after recall stimulation. Immunophenotyping identified L133 as having a significantly lower CD4/CD8 ratio and a lower frequency of γδ T cells than L130 in the peripheral T cell compartment...

  12. Evaluation of flow cytometric immunophenotyping and DNA analysis for detection of malignant cells in serosal cavity fluids.

    Science.gov (United States)

    Sayed, Douaa M; el-Attar, Madiha M; Hussein, Aliaa A R Mohamed

    2009-07-01

    The serosal cavities are frequent sites of tumor metastasis. The distinction between carcinoma cells, inflammatory cells, and reactive or malignant mesothelial cells can be difficult in cytology. Multicolor flow cytometry (FCM) provides the opportunity to evaluate multiple antigens simultaneously, making it possible to characterize various cell populations. In this study, we aimed to assess the diagnostic accuracy of FCM immunophenotyping and DNA in comparison with serum tumor markers and classic cytology for detection of malignant cells in pleural and ascitic fluids. One hundred and nineteen samples of body cavity fluids were analyzed. Immunophenotyping was performed by four-color immunofluorescent staining using monoclonal antibodies against Ber-EP4, cytokeratin, CD3, and CD45. The DNA analysis by FCM was also performed. In addition, serum CA19-9, CEA, AFP, and CA125 were analyzed. Ber-EP4 marker had the highest sensitivity (73%) and specificity (95.5%) in the detection of carcinoma cells in serous fluid and correlated with cytology in most of cases (73%). The mean of DI differed statistically in patients with malignant effusions than in benign one. DI showed no difference in fluids due to infiltration of malignant epithelial cells or hematopoietic malignancy or due to hepatocellular carcinoma developing in cirrhotic liver. Thus, flow cytometry appears to aid not only in the detection of malignant cells but also in the characterization of cell type. On the other hand, although DNA ploidy examination had better sensitivity; it had no advantage over conventional cytopathological examination in identification of malignant cells. 2009 Wiley-Liss, Inc.

  13. Multiparameter flow cytometric analysis of CD4 and CD8 T cell subsets in young and old people

    Directory of Open Access Journals (Sweden)

    Özcelik Dennis

    2008-07-01

    Full Text Available Abstract Background T cell-mediated immunity in elderly people is compromised in ways reflected in the composition of the peripheral T cell pool. The advent of polychromatic flow cytometry has made analysis of cell subsets feasible in unprecedented detail. Results Here we document shifts in subset distribution within naïve (N, central memory (CM and effector memory (EM cells defined by CD45RA and CCR7 expression in the elderly, additionally using the costimulatory receptors CD27 and CD28, as well as the coinhibitory receptors CD57 and KLRG-1, to further dissect these. Although differences between young and old were more marked in CD8 than in CD4 cells, a similar overall pattern prevailed in both. Thus, the use of all these markers together, and inclusion of assays of proliferation and cytokine secretion, may enable the construction of a differentiation scheme applicable to CD4 as well as CD8 cells, with the model (based on Romero et al. suggesting the progression N→CM→EM1→EM2→pE1→pE2→EM4→EM3→E end-stage non-proliferative effector cells. Conclusion Overall, the results suggest that both differences in subset distribution and differences between subsets are responsible for age-related changes in CD8 cells but that differences within rather than between subsets are more prominent for CD4 cells.

  14. Oxidative product formation in irradiated neutrophils. A flow cytometric analysis

    International Nuclear Information System (INIS)

    Wolber, R.A.; Duque, R.E.; Robinson, J.P.; Oberman, H.A.

    1987-01-01

    The effect of irradiation on neutrophil oxidative function was evaluated using a flow cytometric assay of intracellular hydrogen peroxide (H 2 O 2 ) production. This assay quantitates the H 2 O 2 -dependent conversion of the nonfluorescent compound, 2'-7'-dichlorofluorescein (DCFH), into fluorescent 2'-7'-dichlorofluorescein (DCF) on a single-cell basis. Intracellular H 2 O 2 production in response to stimulation with phorbol myristate acetate was not affected by neutrophil irradiation at doses up to 2500 rad. In addition, irradiation of intracellular DCFH and aqueous 2'-7'-dichlorofluorescein diacetate (DCFH-DA) resulted in DCF production, which suggested that oxidative molecules produced by aqueous radiolysis were detected by this assay. This study indicates that radiation doses of 1500 to 2500 rad, which are sufficient to prevent induction of graft-versus-host disease by transfused blood components, are not deleterious to neutrophil oxidative metabolism

  15. Flow cytometric measurement of the metabolism of benzo[a]pyrene by mouse liver cells in culture

    International Nuclear Information System (INIS)

    Bartholomew, J.C.; Wade, C.G.; Dougherty, K.K.

    1984-01-01

    The metabolism of benzo[a]pyrene in individual cells was monitored by flow cytometry. The measurements are based on the alterations that occur in the fluorescence emission spectrum of benzo[a]pyrene when it is converted to various metabolites. Using present instrumentation the technique could easily detect 1x10 6 molecules per cells of benzo[a]pyrene and 1x10 7 molecules per cell of the diol epoxide. The analysis of C3H IOT 1/2 mouse fibroblasts growing in culture indicated that there was heterogeneity in the conversion of the parent compound into diol epoxide derivatives suggesting that some variation in sensitivity to transformation by benzo[a]pyrene may be due to differences in cellular metabolism. The technique allows sensitive detection of metabolites in viable cells, and provides a new approach to the study of factors that influence both metabolism and transformation. (orig.)

  16. Flow cytometric quantification of all phases of the cell cycle and apoptosis in a two-color fluorescence plot.

    Directory of Open Access Journals (Sweden)

    Christine Vignon

    Full Text Available An optimal technology for cell cycle analysis would allow the concomitant measurement of apoptosis, G0, G1, S, G2 and M phases in combination with cell surface phenotyping. We have developed an easy method in flow cytometry allowing this discrimination in an only two-color fluorescent plot. It is based on the concomitant use of 7-amino-actinomycin D and the antibodies anti-Ki67 and anti-phospho(Ser10-histone H3, both conjugated to Alexa Fluor®488 to discriminate G0 and M phases, respectively. The method is particularly valuable in a clinical setting as verified in our laboratory by analyzing human leukemic cells from marrow samples or after exposure to cell cycle modifiers.

  17. Multivariate analysis of flow cytometric data using decision trees.

    Science.gov (United States)

    Simon, Svenja; Guthke, Reinhard; Kamradt, Thomas; Frey, Oliver

    2012-01-01

    Characterization of the response of the host immune system is important in understanding the bidirectional interactions between the host and microbial pathogens. For research on the host site, flow cytometry has become one of the major tools in immunology. Advances in technology and reagents allow now the simultaneous assessment of multiple markers on a single cell level generating multidimensional data sets that require multivariate statistical analysis. We explored the explanatory power of the supervised machine learning method called "induction of decision trees" in flow cytometric data. In order to examine whether the production of a certain cytokine is depended on other cytokines, datasets from intracellular staining for six cytokines with complex patterns of co-expression were analyzed by induction of decision trees. After weighting the data according to their class probabilities, we created a total of 13,392 different decision trees for each given cytokine with different parameter settings. For a more realistic estimation of the decision trees' quality, we used stratified fivefold cross validation and chose the "best" tree according to a combination of different quality criteria. While some of the decision trees reflected previously known co-expression patterns, we found that the expression of some cytokines was not only dependent on the co-expression of others per se, but was also dependent on the intensity of expression. Thus, for the first time we successfully used induction of decision trees for the analysis of high dimensional flow cytometric data and demonstrated the feasibility of this method to reveal structural patterns in such data sets.

  18. Flow cytometric immunoassay for sulfonamides in raw milk

    NARCIS (Netherlands)

    Keizer, de W.; Bienenmann-Ploum, M.; Bergwerff, A.A.; Haasnoot, W.

    2008-01-01

    Sulfonamide antibiotics are applied in veterinary medicine for the treatment of microbial infections. For the detection of residues of sulfonamides in milk, a multi-sulfonamide flow cytometric immunoassay (FCI) was developed using the Luminex MultiAnalyte Profiling (xMAP) technology. In this

  19. Flow cytometric analysis of FSHR, BMRR1B, LHR and apoptosis in granulosa cells and ovulation rate in merino sheep.

    Science.gov (United States)

    Regan, Sheena L P; McFarlane, James R; O'Shea, Tim; Andronicos, Nicholas; Arfuso, Frank; Dharmarajan, Arun; Almahbobi, Ghanim

    2015-08-01

    The aim of the present study was to determine the direct cause of the mutation-induced, increased ovulation rate in Booroola Merino (BB) sheep. Granulosa cells were removed from antral follicles before ovulation and post-ovulation from BB (n=5) and WT (n=12) Merino ewes. Direct immunofluorescence measurement of mature cell surface receptors using flow cytometry demonstrated a significant up-regulation of FSH receptor (FSHR), transforming growth factor beta type 1, bone morphogenetic protein receptor (BMPR1B), and LH receptor (LHR) in BB sheep. The increased density of FSHR and LHR provide novel evidence of a mechanism for increasing the number of follicles that are recruited during dominant follicle selection. The compounding increase in receptors with increasing follicle size maintained the multiple follicles and reduced the apoptosis, which contributed to a high ovulation rate in BB sheep. In addition, we report a mutation-independent mechanism of down-regulation to reduce receptor density of the leading dominant follicle in sheep. The suppression of receptor density coincides with the cessation of mitogenic growth and steroidogenic differentiation as part of the luteinization of the follicle. The BB mutation-induced attenuation of BMPR1B signaling led to an increased density of the FSHR and LHR and a concurrent reduction in apoptosis to increase the ovulation rate. The role of BMPs in receptor modulation is implicated in the development of multiple ovulations. © 2015 Society for Reproduction and Fertility.

  20. Flow cytometric analysis of peripheral blood and tumor-infiltrating regulatory T cells in dogs with oral malignant melanoma.

    Science.gov (United States)

    Tominaga, Makiko; Horiuchi, Yutaka; Ichikawa, Mika; Yamashita, Masao; Okano, Kumiko; Jikumaru, Yuri; Nariai, Yoko; Kadosawa, Tsuyoshi

    2010-05-01

    It is well known that tumor-infiltrating lymphocytes (TILs) and peripheral blood lymphocytes (PBLs) from patients with advanced-stage cancer have a poor immune response. Regulatory T cells (Tregs), characterized by the expression of a cluster of differentiation 4 and intracellular FoxP3 markers, can inhibit antitumor immunoresponse. In the present study, the prevalence of Tregs in peripheral blood and tumor tissue from dogs with oral malignant melanoma was evaluated by triple-color flow cytometry. The percentage of Tregs in the peripheral blood of the dogs with malignancy was significantly increased compared with healthy control dogs, and the percentage of Tregs within tumors was significantly increased compared with Tregs in peripheral blood of dogs with oral malignant melanoma. This finding suggests that the presence of tumor cells induced either local proliferation or selective migration of Tregs to tumor-infiltrated sites. A better understanding of the underlying mechanisms of Treg regulation in patients with cancer may lead to an effective anticancer immunotherapy against canine malignant melanoma and possibly other tumors.

  1. Optimized multiparametric flow cytometric analysis of circulating endothelial cells and their subpopulations in peripheral blood of patients with solid tumors: a technical analysis.

    Science.gov (United States)

    Zhou, Fangbin; Zhou, Yaying; Yang, Ming; Wen, Jinli; Dong, Jun; Tan, Wenyong

    2018-01-01

    Circulating endothelial cells (CECs) and their subpopulations could be potential novel biomarkers for various malignancies. However, reliable enumerable methods are warranted to further improve their clinical utility. This study aimed to optimize a flow cytometric method (FCM) assay for CECs and subpopulations in peripheral blood for patients with solid cancers. An FCM assay was used to detect and identify CECs. A panel of 60 blood samples, including 44 metastatic cancer patients and 16 healthy controls, were used in this study. Some key issues of CEC enumeration, including sample material and anticoagulant selection, optimal titration of antibodies, lysis/wash procedures of blood sample preparation, conditions of sample storage, sufficient cell events to enhance the signal, fluorescence-minus-one controls instead of isotype controls to reduce background noise, optimal selection of cell surface markers, and evaluating the reproducibility of our method, were integrated and investigated. Wilcoxon and Mann-Whitney U tests were used to determine statistically significant differences. In this validation study, we refined a five-color FCM method to detect CECs and their subpopulations in peripheral blood of patients with solid tumors. Several key technical issues regarding preanalytical elements, FCM data acquisition, and analysis were addressed. Furthermore, we clinically validated the utility of our method. The baseline levels of mature CECs, endothelial progenitor cells, and activated CECs were higher in cancer patients than healthy subjects ( P technical issues found in previously published assays and validated the reproducibility and sensitivity of our proposed method. Future work is required to explore the potential of our optimized method in clinical oncologic applications.

  2. Immunophenotypic Characterization of Human Bone Marrow Mast Cells. A Flow Cytometric Study of Normal and Pathological Bone Marrow Samples

    Directory of Open Access Journals (Sweden)

    Luis Escribano

    1998-01-01

    Full Text Available The goal of the present paper was to define the immunophenotype of bone marrow mast cells (BMMC from healthy controls and patients with hematologic malignancies (HM based on the use of multiple stainings with monoclonal antibodies analyzed by flow cytometry. Our results show that BMMC from both groups of individuals display a similar but heterogenous immunophenotype. The overall numbers of BMMC are higher in the HM group of individuals (p = 0.08. Three patterns of antigen expression were detected: (1 markers constantly positive in all cases analyzed (CD9, CD29, CD33, CD43, CD44, CD49d, CD49e, CD51, CD71, CD117, and FcεRI, (2 antigens that were constantly negative (CD1a, CD2, CD3, CD5, CD6, CD11a, CD14, CD15, CD16, CD19, CD20, CD21, CD23, CD25, CD30, CD34, CD38, CD41a, CD42b, CD65, CD66b, HLA-DR, and CD138, and (3 markers that were positive in a variable proportion of cases – CD11b (50%, CD11c (77%, CD13 (40%, CD18 (20%, CD22 (68%, CD35 (27%, CD40 (67%, CD54 (88% and CD61 (40%. In addition, BMMC from all cases explored were CD45+, and this antigen was expressed at an intensity similar to that of mature granulocytes.

  3. Technical discussions II - Flow cytometric analysis

    NARCIS (Netherlands)

    Cunningham, A; Cid, A; Buma, AGJ

    In this paper the potencial of flow cytometry as applied to the aquatic life sciences is discussed. The use of flow cytometry for studying the ecotoxicology of phytoplankton was introduced. On the other hand, the new flow cytometer EUROPA was presented. This is a multilaser machine which has been

  4. Intrinsic properties of so-called dormant probiotic bacteria, determined by flow cytometric viability assays.

    Science.gov (United States)

    Lahtinen, Sampo J; Ouwehand, Arthur C; Reinikainen, Johanna P; Korpela, Jaakko M; Sandholm, Jouko; Salminen, Seppo J

    2006-07-01

    Plate counting and four culture-independent flow cytometric assays were used to determine the viability and intrinsic properties of three probiotic strains during storage. The strains showed reduction in plate counts but were able to maintain esterase activity, intact cytoplasmic membrane, and pH gradient. The apparently uncultivable probiotic cells were active and stress resistant.

  5. Intrinsic Properties of So-Called Dormant Probiotic Bacteria, Determined by Flow Cytometric Viability Assays

    OpenAIRE

    Lahtinen, Sampo J.; Ouwehand, Arthur C.; Reinikainen, Johanna P.; Korpela, Jaakko M.; Sandholm, Jouko; Salminen, Seppo J.

    2006-01-01

    Plate counting and four culture-independent flow cytometric assays were used to determine the viability and intrinsic properties of three probiotic strains during storage. The strains showed reduction in plate counts but were able to maintain esterase activity, intact cytoplasmic membrane, and pH gradient. The apparently uncultivable probiotic cells were active and stress resistant.

  6. Flow cytometric evaluation of the contribution of ionic silver to genotoxic potential of nanosilver in human liver HepG2 and colon Caco2 cells.

    Science.gov (United States)

    Sahu, Saura C; Njoroge, Joyce; Bryce, Steven M; Zheng, Jiwen; Ihrie, John

    2016-04-01

    Exposure to nanosilver found in food- and cosmetics-related consumer products is of public concern because of the lack of information about its safety. In this study, two widely used in vitro cell culture models, human liver HepG2 and colon Caco2 cells, and the flow cytometric micronucleus (FCMN) assay were evaluated as tools for rapid predictive screening of the potential genotoxicity of nanosilver. Recently, we reported the genotoxicity of 20 nm nanosilver using these systems. In the current study presented here, we tested the hypothesis that the nanoparticle size and cell types were critical determinants of its genotoxicity. To test this hypothesis, we used the FCMN assay to evaluate the genotoxic potential of 50 nm nanosilver of the same shape, composition, surface charge and obtained from the same commercial source using the same experimental conditions and in vitro models (HepG2 and Caco2) as previously tested for the 20 nm silver. Results of our study show that up to the concentrations tested in these cultured cell test systems, the smaller (20 nm) nanoparticle is genotoxic to both the cell types by inducing micronucleus (MN). However, the larger (50 nm) nanosilver induces MN only in HepG2 cells, but not in Caco2 cells. Also in this study, we evaluated the contribution of ionic silver to the genotoxic potential of nanosilver using silver acetate as the representative ionic silver. The MN frequencies in HepG2 and Caco2 cells exposed to the ionic silver in the concentration range tested are not statistically significant from the control values except at the top concentrations for both the cell types. Therefore, our results indicate that the ionic silver may not contribute to the MN-forming ability of nanosilver in HepG2 and Caco2 cells. Also our results suggest that the HepG2 and Caco2 cell cultures and the FCMN assay are useful tools for rapid predictive screening of a genotoxic potential of food- and cosmetics-related chemicals including nanosilver

  7. Optimized multiparametric flow cytometric analysis of circulating endothelial cells and their subpopulations in peripheral blood of patients with solid tumors: a technical analysis

    Directory of Open Access Journals (Sweden)

    Zhou F

    2018-03-01

    Full Text Available Fangbin Zhou,1,2 Yaying Zhou,3 Ming Yang,1 Jinli Wen,3 Jun Dong,4 Wenyong Tan1 1Department of Oncology, The Second Clinical Medical College, Shenzhen People’s Hospital, Jinan University, Shenzhen, People’s Republic of China; 2Integrated Chinese and Western Medicine Postdoctoral Research Station, Jinan University, Guangzhou, People’s Republic of China; 3Clinical Medical Research Center, The Second Clinical Medical College, Shenzhen People’s Hospital, Jinan University, Shenzhen, People’s Republic of China; 4Department of Pathophysiology, Key Laboratory of the State Administration of Traditional Chinese Medicine, Medical College of Jinan University, Guangzhou, People’s Republic of China Background: Circulating endothelial cells (CECs and their subpopulations could be potential novel biomarkers for various malignancies. However, reliable enumerable methods are warranted to further improve their clinical utility. This study aimed to optimize a flow cytometric method (FCM assay for CECs and subpopulations in peripheral blood for patients with solid cancers.Patients and methods: An FCM assay was used to detect and identify CECs. A panel of 60 blood samples, including 44 metastatic cancer patients and 16 healthy controls, were used in this study. Some key issues of CEC enumeration, including sample material and anticoagulant selection, optimal titration of antibodies, lysis/wash procedures of blood sample preparation, conditions of sample storage, sufficient cell events to enhance the signal, fluorescence-minus-one controls instead of isotype controls to reduce background noise, optimal selection of cell surface markers, and evaluating the reproducibility of our method, were integrated and investigated. Wilcoxon and Mann–Whitney U tests were used to determine statistically significant differences.Results: In this validation study, we refined a five-color FCM method to detect CECs and their subpopulations in peripheral blood of patients

  8. Flow cytometric fingerprinting for microbial strain discrimination and physiological characterization.

    Science.gov (United States)

    Buysschaert, Benjamin; Kerckhof, Frederiek-Maarten; Vandamme, Peter; De Baets, Bernard; Boon, Nico

    2018-02-01

    The analysis of microbial populations is fundamental, not only for developing a deeper understanding of microbial communities but also for their engineering in biotechnological applications. Many methods have been developed to study their characteristics and over the last few decades, molecular analysis tools, such as DNA sequencing, have been used with considerable success to identify the composition of microbial populations. Recently, flow cytometric fingerprinting is emerging as a promising and powerful method to analyze bacterial populations. So far, these methods have primarily been used to observe shifts in the composition of microbial communities of natural samples. In this article, we apply a flow cytometric fingerprinting method to discriminate among 29 Lactobacillus strains. Our results indicate that it is possible to discriminate among 27 Lactobacillus strains by staining with SYBR green I and that the discriminatory power can be increased by combined SYBR green I and propidium iodide staining. Furthermore, we illustrate the impact of physiological changes on the fingerprinting method by demonstrating how flow cytometric fingerprinting is able to discriminate the different growth phases of a microbial culture. The sensitivity of the method is assessed by its ability to detect changes in the relative abundance of a mix of polystyrene beads down to 1.2%. When a mix of bacteria was used, the sensitivity was as between 1.2% and 5%. The presented data demonstrate that flow cytometric fingerprinting is a sensitive and reproducible technique with the potential to be applied as a method for the dereplication of bacterial isolates. © 2017 International Society for Advancement of Cytometry. © 2017 International Society for Advancement of Cytometry.

  9. A rapid flow cytometric method for determining the cellular composition of bronchoalveolar lavage fluid cells in mouse models of asthma

    NARCIS (Netherlands)

    van Rijt, Leonie S.; Kuipers, Harmjan; Vos, Nanda; Hijdra, Daniëlle; Hoogsteden, Henk C.; Lambrecht, Bart N.

    2004-01-01

    Mouse models of allergic asthma are increasingly used to study the immunopathology of this complex disorder. The degree and type of airway inflammation is often studied by determination of differential cell counts on cytospins of bronchoalveolar lavage fluid (BALF) cells stained with May-Grünwald

  10. Stereologic, histopathologic, flow cytometric, and clinical parameters in the prognostic evaluation of 74 patients with intraoral squamous cell carcinomas

    DEFF Research Database (Denmark)

    Bundgaard, T; Sørensen, Flemming Brandt; Gaihede, M

    1992-01-01

    , tumor size, and the TNM classification. RESULTS: The investigation showed a significant difference between the volume-weighted mean nuclear volume (nuclear vv) of oral leukoplakia (n = 29) and oral squamous cell carcinomas (P = 0.001). The value of the parameters as prognostic indicators of survival...

  11. High-Throughput Flow Cytometric Method for the Simultaneous Measurement of CAR-T Cell Characterization and Cytotoxicity against Solid Tumor Cell Lines.

    Science.gov (United States)

    Martinez, Emily M; Klebanoff, Samuel D; Secrest, Stephanie; Romain, Gabrielle; Haile, Samuel T; Emtage, Peter C R; Gilbert, Amy E

    2018-04-01

    High-throughput flow cytometry is an attractive platform for the analysis of adoptive cellular therapies such as chimeric antigen receptor T cell therapy (CAR-T) because it allows for the concurrent measurement of T cell-dependent cellular cytotoxicity (TDCC) and the functional characterization of engineered T cells with respect to percentage of CAR transduction, T cell phenotype, and measurement of T cell function such as activation in a single assay. The use of adherent tumor cell lines can be challenging in these flow-based assays. Here, we present the development of a high-throughput flow-based assay to measure TDCC for a CAR-T construct co-cultured with multiple adherent tumor cell lines. We describe optimal assay conditions (such as adherent cell dissociation techniques to minimize impact on cell viability) that result in robust cytotoxicity assays. In addition, we report on the concurrent use of T cell transduction and activation antibody panels (CD25) that provide further dissection of engineered T cell function. In conclusion, we present the development of a high-throughput flow cytometry method allowing for in vitro interrogation of solid tumor, targeting CAR-T cell-mediated cytotoxicity, CAR transduction, and engineered T cell characterization in a single assay.

  12. Flow cytometric immunophenotyping of regulatory T cells in chronic lymphocytic leukemia: comparative assessment of various markers and use of novel antibody panel with CD127 as alternative to transcription factor FoxP3.

    Science.gov (United States)

    Dasgupta, Alakananda; Mahapatra, Manoranjan; Saxena, Renu

    2013-04-01

    This study analyzed the frequency of regulatory T cells (Tregs) in chronic lymphocytic leukemia (CLL) by multiparameter flow cytometric immunophenotyping. Patients showed significantly increased frequencies of Tregs as compared to controls, a significantly higher percentage than that identified by previous studies, possibly indicating a different prognosis of CLL in different parts of the world and, more precisely, a worse prognosis of CLL in the Indian population. A higher frequency of Tregs was also seen in advanced stage of disease with significantly reduced frequencies of Tregs in patients with CLL after chemotherapy. A significant proportion of CD127low/-FoxP3+ Tregs expressed only low levels of CD25. Thus, CD127 appears to be a better marker than CD25 for the identification of CD4+FoxP3+ T cells as potential Tregs. Our results suggest that the specificity and sensitivity of CD4+CD127low/- cells are comparable to those of CD4+FoxP3+, which is the gold standard, and can be used as an alternative. This novel flow cytometric antibody panel with fewer number of antibodies is cost-effective and can be used to enumerate Tregs in resource-limited settings.

  13. Flow Cytometric Bead Sandwich Assay Based on a Split Aptamer.

    Science.gov (United States)

    Shen, Luyao; Bing, Tao; Liu, Xiangjun; Wang, Junyan; Wang, Linlin; Zhang, Nan; Shangguan, Dihua

    2018-01-24

    A few aptamers still bind their targets after being split into two moieties. Split aptamers have shown great potential in the development of aptameric sensors. However, only a few split aptamers have been generated because of lack of knowledge on the binding structure of their parent aptamers. Here, we report the design of a new split aptamer and a flow cytometric bead sandwich assay using a split aptamer instead of double antibodies. Through DMS footprinting and mutation assay, we figured out the target-binding moiety and the structure-stabilizing moiety of the l-selectin aptamer, Sgc-3b. By separating the duplex strand in the structure-stabilizing moiety, we obtained a split aptamer that bound l-selectin. After optimization of one part of the split sequence to eliminate the nonspecific binding of the split sequence pair, we developed a split-aptamer-based cytometric bead assay (SACBA) for the detection of soluble l-selectin. SACBA showed good sensitivity and selectivity to l-selectin and was successfully applied for the detection of spiked l-selectin in the human serum. The strategies for generating split aptamers and designing the split-aptamer-based sandwich assay are simple and efficient and show good practicability in aptamer engineering.

  14. Flow-cytometric measurement of CD4-8- T cells bearing T-cell receptor αβ chains, 1

    International Nuclear Information System (INIS)

    Kusunoki, Yoichiro; Hirai, Yuko; Kyoizumi, Seishi; Akiyama, Mitoshi.

    1992-09-01

    In this study we detected rare, possibly abnormal, T cells bearing CD3 surface antigen and T-cell receptor (TCR) αβ chains but lacking both CD4 and CD8 antigens (viz., TCRαβ + CD4 - 8 - cells, as determined by flow cytometry). The TCRαβ + CD4 - 8 - T cells were detected at a mean frequency of 0.63 ± 0.35 % (mean ± standard deviation) in peripheral blood TCRαβ + cells of 119 normal persons. Two unusual cases besides the 119 normal persons showed extremely elevated frequencies of TCRαβ + CD4 - 8 - T cells, viz., approximately 5 % to 10 % and 14 % to 19 % in whole TCRαβ + cells. Both individuals were males who were otherwise physiologically quite normal with no history of severe illness, and these high frequencies were also observed in blood samples collected 2 or 8 years prior to the current measurements. The TCRαβ + CD4 - 8 - T cells of the two individuals were found to express mature T-cell markers such as CD2,3, and 5 antigens, as well as natural killer (NK) cell markers, viz., CD11b, 16, 56, and 57 antigens, when peripheral blood lymphocytes were subjected to three-color flow cytometry. Lectin-dependent or redirected antibody-dependent cell-mediated cytotoxicities were observed for both freshly sorted TCRαβ + CD4 - 8 - cells and in vitro established clones. Nevertheless, NK-like activity was not detected. Further, Southern blot analysis of TCRβ and γ genes revealed identical rearrangement patterns for all the TCRαβ + CD4 - 8 - clones established in vitro. These results suggest that the TCRαβ + CD4 - 8 - T cells from these two mean exhibit unique characteristics and proliferate clonally in vivo. (author)

  15. Clonal evolution demonstrated by flow cytometric DNA analysis of a human colonic carcinoma grown in nude mice

    DEFF Research Database (Denmark)

    Vindeløv, L L; Spang-Thomsen, M; Visfeldt, J

    1982-01-01

    A spontaneous change in DNA content of a human colonic carcinoma grown in nude mice was observed fortuitously. The tumor initially had a G1 cell DNA content of 1.3 times that of normal cells. Flow cytometric DNA analysis showed in transplant generation 56 the appearance of a new subpopulation which...

  16. THE EFFECT OF LABELING INTENSITY, ESTIMATED BY REAL-TIME CONFOCAL LASER SCANNING MICROSCOPY, ON FLOW CYTOMETRIC APPEARANCE AND IDENTIFICATION OF IMMUNOCHEMICALLY LABELED MARINE DINOFLAGELLATES

    NARCIS (Netherlands)

    VRIELING, EG; DRAAIJER, A; VANZEIJL, WJM; PEPERZAK, L; GIESKES, WWC; VEENHUIS, M; Zeijl, Wilhelmus J.M. van

    Two different fluorescein isothiocyanate (FITC) conjugates were used to analyze the effect of labeling intensity on the flow cytometric appearance of marine dinoflagellates labeled with antibodies that specifically recognized the outer cell wall. Location of the labeling was revealed by

  17. Biotinylation of interleukin-2 (IL-2) for flow cytometric analysis of IL-2 receptor expression. Comparison of different methods

    NARCIS (Netherlands)

    M.O. de Jong (Marg); H. Rozemuller (Henk); J.G.J. Bauman (J. G J); J.W.M. Visser (Jan)

    1995-01-01

    textabstractThe main prerequisites for the use of biotinylated ligands to study the expression of growth factor receptors on heterogeneous cell populations, such as peripheral blood or bone marrow, by flow cytometric methods, are that the biotinylated ligand retains its binding ability and that

  18. Flow cytometric analysis of microbial contamination in food industry technological lines--initial study.

    Science.gov (United States)

    Józwa, Wojciech; Czaczyk, Katarzyna

    2012-04-02

    Flow cytometry constitutes an alternative for traditional methods of microorganisms identification and analysis, including methods requiring cultivation step. It enables the detection of pathogens and other microorganisms contaminants without the need to culture microbial cells meaning that the sample (water, waste or food e.g. milk, wine, beer) may be analysed directly. This leads to a significant reduction of time required for analysis allowing monitoring of production processes and immediate reaction in case of contamination or any disruption occurs. Apart from the analysis of raw materials or products on different stages of manufacturing process, the flow cytometry seems to constitute an ideal tool for the assessment of microbial contamination on the surface of technological lines. In the present work samples comprising smears from 3 different surfaces of technological lines from fruit and vegetable processing company from Greater Poland were analysed directly with flow cytometer. The measured parameters were forward and side scatter of laser light signals allowing the estimation of microbial cell contents in each sample. Flow cytometric analysis of the surface of food industry production lines enable the preliminary evaluation of microbial contamination within few minutes from the moment of sample arrival without the need of sample pretreatment. The presented method of fl ow cytometric initial evaluation of microbial state of food industry technological lines demonstrated its potential for developing a robust, routine method for the rapid and labor-saving detection of microbial contamination in food industry.

  19. Flow cytometric sensitivity and characteristics of plasma cells in patients with multiple myeloma or its precursor disease: influence of biopsy site and anticoagulation method.

    Science.gov (United States)

    Manasanch, Elisabet E; Salem, Dalia A; Yuan, Constance M; Tageja, Nishant; Bhutani, Manisha; Kwok, Mary; Kazandjian, Dickran; Carter, George; Steinberg, Seth M; Zuchlinski, Diamond; Mulquin, Marcia; Calvo, Katherine; Maric, Irina; Roschewski, Mark; Korde, Neha; Braylan, Raul; Landgren, Ola; Stetler-Stevenson, Maryalice

    2015-05-01

    Flow cytometry has increasing relevance for prognosis in myeloma and precursor disease (monoclonal gammopathy of unknown significance/smoldering myeloma), yet it has been reported that plasma cell enumeration by flow varies depending on the quality of marrow aspirate and field biopsied in patchy disease. We demonstrated increased sensitivity of flow over immunohistochemistry in abnormal-plasma cell detection in monoclonal gammopathy (n = 59)/smoldering myeloma (n = 87). We prospectively evaluated treatment-na ve smoldering myeloma (n = 9)/myeloma (n = 11) patients for the percentage of abnormal plasma cells/total plasma cell compartment, plasma cell viability/infiltration and flow immunophenotype depending on anticoagulant use, biopsy site and pull sequence in uni-and-bilateral bone marrow biopsies and aspirates. We found no statistical difference regarding the percentage of abnormal plasma cells, their immunophenotype or number/distribution in marrow samples even when obtained by different sequence in aspirates, or anticoagulants (p > 0.05). Our results show that plasma cell enumeration and immunophenotyping by flow cytometry is consistent under different conditions in these populations.

  20. Flow cytometric applications of tumor biology: prospects and pitfalls. [Applications in study of spontaneous dog tumors and in drug and radiation effects on cultured V79 cells

    Energy Technology Data Exchange (ETDEWEB)

    Raju, M.R.; Johnson, T.S.; Tokita, N.; Gillette, E.L.

    1979-01-01

    A brief review of cytometry instrumentation and its potential applications in tumor biology is presented using our recent data. Age-distribution measurements of cells from spontaneous dog tumors and cultured cells after exposure to x rays, alpha particles, or adriamycin are shown. The data show that DNA fluorescence measurements have application in the study of cell kinetics after either radiation or drug treatment. Extensive and careful experimentation is needed to utilize the sophisticated developments in flow cytometry instrumentation.

  1. Flow Cytometric Analysis of the Expression Pattern of Peroxisomal Proteins, Abcd1, Abcd2, and Abcd3 in BV-2 Murine Microglial Cells.

    Science.gov (United States)

    Debbabi, Meryam; Nury, Thomas; Helali, Imen; Karym, El Mostafa; Geillon, Flore; Gondcaille, Catherine; Trompier, Doriane; Najid, Amina; Terreau, Sébastien; Bezine, Maryem; Zarrouk, Amira; Vejux, Anne; Andreoletti, Pierre; Cherkaoui-Malki, Mustapha; Savary, Stéphane; Lizard, Gérard

    2017-01-01

    Microglial cells play important roles in neurodegenerative diseases including peroxisomal leukodystrophies. The BV-2 murine immortalized cells are widely used in the context of neurodegenerative researches. It is therefore important to establish the expression pattern of peroxisomal proteins by flow cytometry in these cells. So, the expression pattern of various peroxisomal transporters (Abcd1, Abcd2, Abcd3) contributing to peroxisomal β-oxidation was evaluated on BV-2 cells by flow cytometry and complementary methods (fluorescence microscopy, and RT-qPCR). By flow cytometry a strong expression of peroxisomal proteins (Abcd1, Abcd2, Abcd3) was observed. These data were in agreement with those obtained by fluorescence microscopy (presence of numerous fluorescent dots in the cytoplasm characteristic of a peroxisomal staining pattern) and RT-qPCR (high levels of Abcd1, Abcd2, and Abcd3 mRNAs). Thus, the peroxisomal proteins (Abcd1, Abcd2, Abcd3) are expressed in BV-2 cells, and can be analyzed by flow cytometry.

  2. Identification of microbes from the surfaces of food-processing lines based on the flow cytometric evaluation of cellular metabolic activity combined with cell sorting.

    Science.gov (United States)

    Juzwa, W; Duber, A; Myszka, K; Białas, W; Czaczyk, K

    2016-09-01

    In this study the design of a flow cytometry-based procedure to facilitate the detection of adherent bacteria from food-processing surfaces was evaluated. The measurement of the cellular redox potential (CRP) of microbial cells was combined with cell sorting for the identification of microorganisms. The procedure enhanced live/dead cell discrimination owing to the measurement of the cell physiology. The microbial contamination of the surface of a stainless steel conveyor used to process button mushrooms was evaluated in three independent experiments. The flow cytometry procedure provided a step towards monitoring of contamination and enabled the assessment of microbial food safety hazards by the discrimination of active, mid-active and non-active bacterial sub-populations based on determination of their cellular vitality and subsequently single cell sorting to isolate microbial strains from discriminated sub-populations. There was a significant correlation (r = 0.97; p vitality and the identification of species from defined sub-populations, although the identified microbes were limited to culturable cells.

  3. Cholesterol sensitivity of detergent resistance: A rapid flow cytometric test for detecting constitutive or induced raft association of membrane proteins

    OpenAIRE

    Imre Gombos, Zsolt Bacsó, Cynthia Detre, Henrietta Nagy, Katalin Goda, Márton Andrásfalvy, Gábor Szabó, János Matkó; Bacsó Zsolt (1963-) (biofizikus); Goda Katalin (1969-) (biofizikus); Szabó Gábor (1953-) (biofizikus)

    2004-01-01

    Lipid rafts are cholesterol- and glycosphingolipid-rich microdomains in the cellular plasma membranes that play critical roles in compartmentalization (concentration, coupling, and isolation) of receptors and signal molecules. Therefore, detecting constitutive or induced raft associations of such proteins is of central interest in cell biology. This has mostly been done with time- and cell-consuming immunobiochemical techniques affected by several sources of artifacts. A flow cytometric analy...

  4. Normal adult ramified microglia separated from other central nervous system macrophages by flow cytometric sorting: Phenotypic differences defined and direct ex vivo antigen presentation to myelin basic protein-reactive CD4{sup +} T cells compared

    Energy Technology Data Exchange (ETDEWEB)

    Ford, A.L.; Goodsall, A.L.; Sedgwick, J.D. [Centenary Institute of Cancer Medicine and Cell Biology, Sydney (Australia)] [and others

    1995-05-01

    Ramified microglia in the adult central nervous system (CNS) are the principal glial element up-regulating MHC class I and II expression in response to inflammatory events or neuronal damage. A proportion of these cells also express MHC class II constitutively in the normal CNS. The role of microglia as APCs for CD4{sup +} cells extravasating into the CNS remains undefined. In this study, using irradiation bone marrow chimeras in CD45-congenic rats, the phenotype CD45{sup low}CD11b/c{sup +} is shown to identify microglial cells specifically within the CNS. Highly purified populations of microglia and nonmicroglial but CNS-associated macrophages (CD45{sup high}CD11b/c{sup +}) have been obtained directly from the adult CNS, by using flow cytometric sorting. Morphologically, freshly isolated microglia vs other CNS macrophages are quite distinct. Of the two populations recovered from the normal CNS, it is the minority CD45{sup high}CD11 b/c{sup +} transitional macrophage population, and not microglia, that is the effective APC for experimental autoimmune encephalomyelitis-inducing CD4{sup +} myelin basic protein (MBP)-reactive T cells. CD45{sup high}CD11b/c{sup +} CNS macrophages also stimulate MBP-reactive T cells without addition of MBP to culture suggesting presentation of endogenous Ag. This is the first study in which microglia vs other CNS macrophages have been analyzed for APC ability directly from the CNS, with substantial cross-contamination between the two populations eliminated. The heterogeneity of these populations in terms of APC function is clearly demonstrated. Evidence is still lacking that adult CNS microglia have the capacity to interact with and stimulate CD4{sup +} T cells to proliferate or secrete IL-2. 60 refs., 6 figs., 1 tab.

  5. Multiparametric flow cytometric analysis of estrogen receptor: a ...

    African Journals Online (AJOL)

    Precise prognostication of breast cancer based on immunohistochemical features is a challenging assay. Thus, there is a need for more sophisticated prognostic determinants. This work aims to investigate the sensitivity of flow cytometry for the accurate evaluation of steroid receptor positive, tumor cells in formalin-fixed ...

  6. Flow cytometric DNA analysis of ducks accumulating 137Cs on a reactor reservoir

    International Nuclear Information System (INIS)

    George, L.S.; Dallas, C.E.; Brisbin, I.L. Jr.; Evans, D.L.

    1991-01-01

    The objective of this study was to detect red blood cell (rbc) DNA abnormalities in male, game-farm mallard ducks as they ranged freely and accumulated 137Cs (radiocesium) from an abandoned nuclear reactor cooling reservoir. Prior to release, the ducks were tamed to enable recapture at will. Flow cytometric measurements conducted at intervals during the first year of exposure yielded cell cycle percentages of DNA (G0/G1, S, G2 + M phases) of rbc, as well as coefficients of variation (CV) in the G0/G1 phase. DNA histograms of exposed ducks were compared with two sets of controls which were maintained 30 and 150 miles from the study site. 137Cs live wholebody burdens were also measured in these animals in a parallel kinetics study, and an approximate steady-state equilibrium was attained after about 8 months. DNA histograms from 2 of the 14 contaminated ducks revealed DNA aneuploid-like patterns after 9 months exposure. These two ducks were removed from the experiment at this time, and when sampled again 1 month later, one continued to exhibit DNA aneuploidy. None of the control DNA histograms demonstrated DNA aneuploid-like patterns. There were no significant differences in cell cycle percentages at any time point between control and exposed animals. A significant increase in CV was observed at 9 months exposure, but after removal of the two ducks with DNA aneuploidy, no significant difference was detected in the group monitored after 12 months exposure. An increased variation in the DNA and DNA aneuploidy could, therefore, be detected in duck rbc using flow cytometric analysis, with the onset of these effects being related to the attainment of maximal levels of 137Cs body burdens in the exposed animals

  7. Early changes in flow cytometric DNA profiles induced by californium-252 neutron brachytherapy in squamocellular carcinomas of the uterine cervix.

    Science.gov (United States)

    Tacev, T; Zaloudík, J; Janáková, L; Vagunda, V

    1998-01-01

    Ninety-five squamocellular carcinomas of the uterine cervix, clinical Stages II and III, were treated by either four schedules combining 252-californium neutron-gamma-radiotherapy with different proportions of a neutron component (9, 6 and 3 Gy) or gamma-irradiation alone. Flow cytometric DNA profiles were obtainable in 72 cases before treatment and 56 cases were monitored for DNA content by flow cytometry (FCM) in weekly intervals by analysis of sequential microbiopsies for one month during and after radiotherapy. DNA aneuploidy was reduced from 40% (25/63) to 19% (9/47) one week within therapy in neutron-treated groups, but not after initial gamma-radiotherapy alone. Extinction of DNA aneuploid subpopulations occurred after neutron therapy in all remaining aneuploid tumors (9/9) during further monitoring, but only in 40% (2/5) of tumors after sole gamma-irradiation. In contrast, proliferation index by more than 50% was more often achieved in groups with a higher gamma-radiation component than after neutrons only. When all therapy-induced DNA flow cytometric events are taken together for evaluation of the effects of various radiotherapy schedules, it appears that the regimen with the maximal neutron dose may not be optimal for all tumors. It is hypothesized that the differences in the early flow cytometric DNA profiles may select the DNA aneuploid squamous cell uterine cervical carcinomas as candidates for combined neutron-brachytherapy, while highly proliferating DNA near-diploid tumors may profit more from treatment with a higher gamma-radiotherapy component. However, these early DNA flow cytometric findings need to be correlated with clinical course of the disease to validate this hypothesis, a process which will be completed at the end of the expected five-year clinical outcome in 2000.

  8. Ultrastructural and flow cytometric analyses of lipid accumulation in microalgae

    Energy Technology Data Exchange (ETDEWEB)

    Solomon, J.A.; Hand, R.E. Jr.; Mann, R.C.

    1986-12-01

    Lipid accumulation in three species of microalgae was investigated with flow cytometry (FCM) and transmission electron microscopy (TEM). Previous studies using batch cultures of a algae have led to the assumption that lipid accumulation in microalgae is a gradual process requiring at least several days for completion. However, FCM reveals, through changes in the chlorophyll:lipid ratio, that the time span required for individual cells to change metabolic state is short. Simultaneous FCM measurements of chlorophyll and nile red (neutral lipid) fluorescence in individual cells of nitrogen-deficient Isochrysis populations revealed a bimodal population distribution as one stage in the lipid accumulation process. The fact that two discrete populations exist, with few cells in an intermediate stage, suggests rapid response to a liqid trigger. Interpretations of light and electron microscopic observations are consistent with this hypothesis. The time required for an entire population to achieve maximum lipid content is considerably longer than that required for a single cell, due to the variation in response time among cells. In this study high lipid cultures were sometimes obtained by using FCM to separate high lipid cells from the remainder of the population. FCM holds much promise for strain enhancement but considerable developmental work, directed at providing more consistent results, remains to be done. 8 refs., 35 figs.

  9. Cluster Analysis of Flow Cytometric List Mode Data on a Personal Computer

    NARCIS (Netherlands)

    Bakker Schut, Tom C.; Bakker schut, T.C.; de Grooth, B.G.; Greve, Jan

    1993-01-01

    A cluster analysis algorithm, dedicated to analysis of flow cytometric data is described. The algorithm is written in Pascal and implemented on an MS-DOS personal computer. It uses k-means, initialized with a large number of seed points, followed by a modified nearest neighbor technique to reduce

  10. A novel flow cytometric assay for measurement of In Vivo pulmonary neutrophil phagocytosis

    Directory of Open Access Journals (Sweden)

    Gentry-Nielsen Martha J

    2006-07-01

    Full Text Available Abstract Background Phagocytosis assays are traditionally performed in vitro using polymorphonuclear leukocytes (PMNs isolated from peripheral blood or the peritoneum and heat-killed, pre-opsonized organisms. These assays may not adequately mimic the environment within the infected lung. Our laboratory therefore has developed a flow cytometric in vivo phagocytosis assay that enables quantification of PMN phagocytosis of viable bacteria within the lungs of rats. In these studies, rats are injected transtracheally with lipopolysaccharide (LPS to recruit PMNs to their lungs. They are then infected with live 5(-and 6 carboxyfluorescein diacetate succinimidyl ester (CFDA/SE labeled type 3 Streptococcus pneumoniae. Bronchoalveolar lavage is performed and resident alveolar macrophages and recruited PMNs are labeled with monoclonal antibodies specific for surface epitopes on each cell type. Three color flow cytometry is utilized to identify the cell types, quantify recruitment, and determine uptake of the labeled bacteria. Results The viability of the alveolar macrophages and PMNs isolated from the lavage fluid was >95%. The values of the percentage of PMNs in the lavage fluid as well as the percentage of PMNs associated with CFSE-labeled S. pneumoniae as measured through flow cytometry showed a high degree of correlation with the results from manual counting of cytospin slides. Conclusion This assay is suitable for measuring bacterial uptake within the infected lung. It can be adapted for use with other organisms and/or animal model systems.

  11. A short-term in vitro test for tumour sensitivity to adriamycin based on flow cytometric DNA analysis

    DEFF Research Database (Denmark)

    Engelholm, S A; Spang-Thomsen, M; Vindeløv, L L

    1983-01-01

    A new method to test the sensitivity of tumour cells to chemotherapy is presented. Tumour cells were incubated in vitro on agar, and drug-induced cell cycle perturbation was monitored by flow cytometric DNA analysis. In the present study the method was applied to monitor the effect of adriamycin...... tumours. The dose level causing maximum accumulation in the G2 + M phase is suggested as a parameter for quantifying the sensitivity. The results indicate that the method can be extended to sensitivity testing of human tumours....

  12. Novel calibration method for flow cytometric fluorescence resonance energy transfer measurements between visible fluorescent proteins.

    Science.gov (United States)

    Nagy, Peter; Bene, László; Hyun, William C; Vereb, György; Braun, Manuela; Antz, Christof; Paysan, Jacques; Damjanovich, Sándor; Park, John W; Szöllősi, János

    2005-10-01

    The combination of fluorescence resonance energy transfer (FRET) and flow cytometry offers a statistically firm approach to study protein associations. Fusing green fluorescent protein (GFP) to a studied protein usually does not disturb the normal function of a protein, but quantitation of FRET efficiency calculated between GFP derivatives poses a problem in flow cytometry. We generated chimeras in which cyan fluorescent protein (CFP) was separated by amino acid linkers of different sizes from yellow fluorescent protein (YFP) and used them to calibrate the cell-by-cell flow cytometric FRET measurements carried out on two different dual-laser flow cytometers. Then, CFP-Kip1 was coexpressed in yeast cells with YFP and cyclin-dependent kinase-2 (Cdk2) and served as a positive control for FRET measurements, and CFP-Kip1 coexpressed with a random peptide fused to YFP was the negative control. We measured donor, direct, and sensitized acceptor fluorescence intensities and developed a novel way to calculate a factor (alpha) that characterized the fluorescence intensity of acceptor molecules relative to the same number of excited donor molecules, which is essential for quantifying FRET efficiency. This was achieved by calculating FRET efficiency in two different ways and minimizing the squared difference between the two results by changing alpha. Our method reliably detected the association of Cdk2 with its inhibitor, Kip1, whereas the nonspecific FRET efficiency between Cdk2 and a random peptide was negligible. We identified and sorted subpopulations of yeast cells showing interaction between the studied proteins. We have described a straightforward novel calibration method to accurately quantitate FRET efficiency between GFP derivatives in flow cytometry.

  13. Flow cytometric detection of growth factor receptors in autografts and analysis of growth factor concentrations in autologous stem cell transplantation: possible significance for platelet recovery

    DEFF Research Database (Denmark)

    Schiødt, I; Jensen, Charlotte Harken; Kjaersgaard, E

    2000-01-01

    In order to improve prediction of hematopoietic recovery, we conducted a pilot study, analyzing the significance of growth factor receptor expression in autografts as well as endogenous growth factor levels in blood before, during and after stem cell transplantation. Three early acting (stem cell...

  14. Fine needle aspirate flow cytometric phenotyping characterizes immunosuppressive nature of the mesothelioma microenvironment.

    Science.gov (United States)

    Lizotte, Patrick H; Jones, Robert E; Keogh, Lauren; Ivanova, Elena; Liu, Hongye; Awad, Mark M; Hammerman, Peter S; Gill, Ritu R; Richards, William G; Barbie, David A; Bass, Adam J; Bueno, Raphael; English, Jessie M; Bittinger, Mark; Wong, Kwok-Kin

    2016-08-19

    With the emergence of checkpoint blockade and other immunotherapeutic drugs, and the growing adoption of smaller, more flexible adaptive clinical trial designs, there is an unmet need to develop diagnostics that can rapidly immunophenotype patient tumors. The ability to longitudinally profile the tumor immune infiltrate in response to immunotherapy also presents a window of opportunity to illuminate mechanisms of resistance. We have developed a fine needle aspirate biopsy (FNA) platform to perform immune profiling on thoracic malignancies. Matching peripheral blood, bulk resected tumor, and FNA were analyzed from 13 mesothelioma patients. FNA samples yielded greater numbers of viable cells when compared to core needle biopsies. Cell numbers were adequate to perform flow cytometric analyses on T cell lineage, T cell activation and inhibitory receptor expression, and myeloid immunosuppressive checkpoint markers. FNA samples were representative of the tumor as a whole as assessed by head-to-head comparison to single cell suspensions of dissociated whole tumor. Parallel analysis of matched patient blood enabled us to establish quality assurance criteria to determine the accuracy of FNA procedures to sample tumor tissue. FNA biopsies provide a diagnostic to rapidly phenotype the tumor immune microenvironment that may be of great relevance to clinical trials.

  15. Super-resolved calibration-free flow cytometric characterization of platelets and cell-derived microparticles in platelet-rich plasma.

    Science.gov (United States)

    Konokhova, Anastasiya I; Chernova, Darya N; Moskalensky, Alexander E; Strokotov, Dmitry I; Yurkin, Maxim A; Chernyshev, Andrei V; Maltsev, Valeri P

    2016-02-01

    Importance of microparticles (MPs), also regarded as extracellular vesicles, in many physiological processes and clinical conditions motivates one to use the most informative and precise methods for their characterization. Methods based on individual particle analysis provide statistically reliable distributions of MP population over characteristics. Although flow cytometry is one of the most powerful technologies of this type, the standard forward-versus-side-scattering plots of MPs and platelets (PLTs) overlap considerably because of similarity of their morphological characteristics. Moreover, ordinary flow cytometry is not capable of measurement of size and refractive index (RI) of MPs. In this study, we 1) employed the potential of the scanning flow cytometer (SFC) for identification and characterization of MPs from light scattering; 2) suggested the reference method to characterize MP morphology (size and RI) with high precision; and 3) determined the lowest size of a MP that can be characterized from light scattering with the SFC. We equipped the SFC with 405 and 488 nm lasers to measure the light-scattering profiles and side scattering from MPs, respectively. The developed two-stage method allowed accurate separation of PLTs and MPs in platelet-rich plasma. We used two optical models for MPs, a sphere and a bisphere, in the solution of the inverse light-scattering problem. This solution provides unprecedented precision in determination of size and RI of individual spherical MPs-median uncertainties (standard deviations) were 6 nm and 0.003, respectively. The developed method provides instrument-independent quantitative information on MPs, which can be used in studies of various factors affecting MP population. © 2015 International Society for Advancement of Cytometry.

  16. Flow cytometric analysis of the granulocyte respiratory burst: a comparison study of fluorescent probes.

    Science.gov (United States)

    Vowells, S J; Sekhsaria, S; Malech, H L; Shalit, M; Fleisher, T A

    1995-01-13

    Chronic granulomatous disease (CGD) is a rare recessive disorder caused by defects in the NADPH oxidase enzyme complex of phagocytes (neutrophils, eosinophils and monocytes). CGD phagocytes fail to produce superoxide and other reactive oxygen species following cell activation (Malech, 1993). The products of oxidase activation can be measured in individual cells by flow cytometry using specific fluorescent probes that increase fluorescence upon oxidation (Trinkle et al., 1987). This approach can be used to confirm a diagnosis of CGD, and to detect the normal/abnormal phagocyte mixture that characterizes the X-linked CGD carrier state. Three fluorescent probes have been described as useful for this purpose: 2'7'-dichlorofluorescin diacetate (DCF) (Bass et al., 1983), 5,6-carboxy-2'7'-dichlorofluorescein diacetate, bis(acetoxymethyl) ester (C-DCF) (Hockenbery et al., 1993) and dihydrorhodamine 123 (DHR) (Rothe et al., 1988; Kinsey et al., 1987). A direct comparison between these three probes has not been reported. In this study we performed a direct comparison between these three probes, evaluating their ability in flow cytometric analysis to maximize fluorescent separation between activated CGD patient and normal granulocytes. Using a whole blood technique with phorbol myristate acetate (PMA) as an activator, it was found that DHR loaded normal granulocytes had a fluorescence intensity which, upon activation, was 48-fold higher than that of C-DCF loaded granulocytes and seven-fold higher than DCF loaded granulocytes (P < 0.001). Use of sodium azide to decrease the catabolism of H2O2 enhanced the fluorescence of DCF by 140%, C-DCF by 45% and DHR by 25%, suggesting that DCF is primarily sensitive to H2O2. DCF and DHR were then evaluated for sensitivity in the detection of small percentages of normal cells in a CGD/normal granulocyte mixture. Normal sub-populations as small as 0.1% could clearly be distinguished using DHR, while DCF was insensitive at this level. Based

  17. The value of flow cytometric analysis of platelet glycoprotein expression of CD34+ cells measured under conditions that prevent P-selectin-mediated binding of platelets

    NARCIS (Netherlands)

    Dercksen, M. W.; Weimar, I. S.; Richel, D. J.; Breton-Gorius, J.; Vainchenker, W.; Slaper-Cortenbach, C. M.; Pinedo, H. M.; von dem Borne, A. E.; Gerritsen, W. R.; van der Schoot, C. E.

    1995-01-01

    In the present study, we show by adhesion assays and ultrastructural studies that platelets can bind to CD34+ cells from human blood and bone marrow and that this interaction interferes with the accurate detection of endogenously expressed platelet glycoproteins (GPs). The interaction between these

  18. Flow cytometric method for measuring chromatin fragmentation in fixed sperm from yellow perch (Perca flavescens)

    Science.gov (United States)

    Jenkins, Jill A.; Draugelis-Dale, Rassa O.; Pinkney, Alfred E.; Iwanowicz, Luke R.; Blazer, Vicki

    2015-01-01

    Declining harvests of yellow perch, Perca flavescens, in urbanized watersheds of Chesapeake Bay have prompted investigations of their reproductive fitness. The purpose of this study was to establish a flow cytometric technique for DNA analysis of fixed samples sent from the field to provide reliable gamete quality measurements. Similar to the sperm chromatin structure assay, measures were made on the susceptibility of nuclear DNA to acid-induced denaturation, but used fixed rather than live or thawed cells. Nuclei were best exposed to the acid treatment for 1 minute at 37 °C followed by the addition of cold (4 °C) propidium iodide staining solution before flow cytometry. The rationale for protocol development is presented graphically through cytograms. Field results collected in 2008 and 2009 revealed DNA fragmentation up to 14.5%. In 2008, DNA fragmentation from the more urbanized watersheds was significantly greater than from reference sites (P = 0.026) and in 2009, higher percentages of haploid testicular cells were noted from the less urbanized watersheds (P = 0.032) indicating better reproductive condition at sites with less urbanization. For both years, total and progressive live sperm motilities by computer-assisted sperm motion analysis ranged from 19.1% to 76.5%, being significantly higher at the less urbanized sites (P chromatin compaction levels from samples translocated over distance and time. The protocol provides an approach that can be modified for other species across taxa.

  19. Validation of flow cytometric analysis of platelet function in patients with a suspected platelet function defect.

    Science.gov (United States)

    van Asten, I; Schutgens, R E G; Baaij, M; Zandstra, J; Roest, M; Pasterkamp, G; Huisman, A; Korporaal, S J A; Urbanus, R T

    2018-01-16

    Essentials The diagnosis of mild platelet function disorders (PFDs) is challenging. Validation of flow cytometric testing in patients with suspected PFDs is required. Flow cytometry has added value to light transmission aggregometry (LTA) in diagnosis of PFDs. There is fair agreement in diagnosing PFDs between LTA and flow cytometry. Background Light transmission aggregometry (LTA) is the most commonly used test for the diagnosis of platelet function disorders (PFDs), but has moderate sensitivity for mild PFDs. Flow cytometry has been recommended for additional diagnostics of PFDs but is not yet standardized as a diagnostic test. We developed a standardized protocol for flow cytometric analysis of platelet function that measures fibrinogen binding and P-selectin expression as platelet activation markers in response to agonist stimulation. Objectives To determine the additional value of flow cytometric platelet function testing to standard LTA screening in a cross-sectional cohort of patients with a suspected PFD. Methods Platelet function was assessed with flow cytometry and LTA in 107 patients suspected of a PFD in whom von Willebrand disease and coagulation factor deficiencies were excluded. Both tests were compared in terms of agreement and discriminative ability for diagnosing patients with PFDs. Results Out of 107 patients, 51 patients had an elevated bleeding score; 62.7% of the patients had abnormal platelet function measured with flow cytometry and 54.2% of the patients were abnormal based on LTA. There was fair agreement between LTA and flow cytometry (κ = 0.32). The discriminative ability of flow cytometric analysis in patients with an elevated bleeding score was good (AUC 0.82, 0.74-0.90), but moderate for LTA (AUC 0.70, 0.60-0.80). Both tests combined had a better discriminative ability (AUC 0.87, 0.80-0.94). Conclusion Flow cytometric analysis of platelet function has added value in diagnostics of PFDs in patients with unexplained bleeding tendency.

  20. A flow-cytometric NK-cytotoxicity assay adapted for use in rat repeated dose toxicity studies

    International Nuclear Information System (INIS)

    Marcusson-Staahl, Maritha; Cederbrant, Karin

    2003-01-01

    A recent regulatory document for immunotoxicity testing of new pharmaceutical drugs includes cytotoxic natural killer (NK)-cell function as a required parameter in repeated dose toxicity studies. The classical 51 Cr-release assay is the conventional test for cytotoxicity testing but several drawbacks with this assay has increased the demand for new reliable test systems. Here, we describe the optimisation of a flow-cytometric cytotoxicity assay especially adapted for regulatory rat studies in drug development. The test principle is based on target cell labelling with 5-(6)-carboxy-fluorescein succinimidyl ester (CFSE) and subsequent DNA-labelling with propidium iodide (PI) for identification of target cells with compromised cell membranes. The results are expressed as percentage of dead targets on a cell-to-cell basis. The final format of the assay includes 0.5 ml peripheral blood, 1.25x10 5 effector cells per sample, and collection of 500 target events by flow-cytometry. When NKR-P1+ cells were removed from the effector cell population by magnetic depletion the relative proportion decreased from 6 to 0.08%. The corresponding cytotoxic activity decreased from 68 to 8%. Also, the cytotoxic activity showed a significant and positive correlation with the proportion of NK-cells present in the effector cell suspension. Thus, the cytotoxicity measured is almost exclusively exerted by NK-cells. The current flow-cytometric test benefits from using peripheral blood as a source for effector cells since it will not conflict with the use of spleen for histopathological investigations in repeated dose toxicity studies. Additionally, since only a minimal number of effector cells are required per sample repeated testing of the same animal is enabled

  1. A Flow-Cytometric Gram-Staining Technique for Milk-Associated Bacteria

    Science.gov (United States)

    Holm, Claus; Jespersen, Lene

    2003-01-01

    A Gram-staining technique combining staining with two fluorescent stains, Oregon Green-conjugated wheat germ agglutinin (WGA) and hexidium iodide (HI) followed by flow-cytometric detection is described. WGA stains gram-positive bacteria while HI binds to the DNA of all bacteria after permeabilization by EDTA and incubation at 50°C for 15 min. For WGA to bind to gram-positive bacteria, a 3 M potassium chloride solution was found to give the highest fluorescence intensity. A total of 12 strains representing some of the predominant bacterial species in bulk tank milk and mixtures of these were stained and analyzed by flow cytometry. Overall, the staining method showed a clear differentiation between gram-positive and gram-negative bacterial populations. For stationary-stage cultures of seven gram-positive bacteria and five gram-negative bacteria, an average of 99% of the cells were correctly interpreted. The method was only slightly influenced by the growth phase of the bacteria or conditions such as freezing at −18°C for 24 h. For any of these conditions, an average of at least 95% of the cells were correctly interpreted. When stationary-stage cultures were stored at 5°C for 14 days, an average of 86% of the cells were correctly interpreted. The Gram-staining technique was applied to the flow cytometry analysis of bulk tank milk inoculated with Staphylococcus aureus and Escherichia coli. These results demonstrate that the technique is suitable for analyzing milk samples without precultivation. PMID:12732558

  2. Clonal evolution demonstrated by flow cytometric DNA analysis of a human colonic carcinoma grown in nude mice

    DEFF Research Database (Denmark)

    Vindeløv, L L; Spang-Thomsen, M; Visfeldt, J

    1982-01-01

    A spontaneous change in DNA content of a human colonic carcinoma grown in nude mice was observed fortuitously. The tumor initially had a G1 cell DNA content of 1.3 times that of normal cells. Flow cytometric DNA analysis showed in transplant generation 56 the appearance of a new subpopulation whi...... evolution of a tumor would be less pronounced if old subpopulations often become extinct as new ones emerge. Heterogeneity of human tumors is of clinical importance because the individual subpopulations may have different sensitivity patterns to antineoplastic drugs.......A spontaneous change in DNA content of a human colonic carcinoma grown in nude mice was observed fortuitously. The tumor initially had a G1 cell DNA content of 1.3 times that of normal cells. Flow cytometric DNA analysis showed in transplant generation 56 the appearance of a new subpopulation which...... in three passages completely overgrew the original population. The DNA content of the new subpopulation was twice that of the original population. The observation supports the hypothesis of clonal evolution of tumor cell populations. The growth rates of the tumor before and after the change showed...

  3. Flow cytometric chromosome sorting in plants: The next generation

    Czech Academy of Sciences Publication Activity Database

    Vrána, Jan; Šimková, Hana; Kubaláková, Marie; Čihalíková, Jarmila; Doležel, Jaroslav

    2012-01-01

    Roč. 57, č. 3 (2012), s. 331-337 ISSN 1046-2023 R&D Projects: GA ČR GAP501/10/1740 Grant - others:GA MŠk(CZ) ED0007/01/01 Program:ED Institutional research plan: CEZ:AV0Z50380511 Keywords : Chromosome sorting * Flow cytometry * Fluorescence in situ hybridization Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 3.641, year: 2012

  4. Flow cytometric analysis of bone marrow leukocytes in neonatal dogs

    Czech Academy of Sciences Publication Activity Database

    Faldyna, M.; Šinkora, Jiří; Knotigová, P.; Řeháková, Zuzana; Morávková, Alena; Toman, M.

    2003-01-01

    Roč. 95, - (2003), s. 165-176 ISSN 0165-2427 R&D Projects: GA ČR GA524/00/0474; GA ČR GP524/02/P010 Institutional research plan: CEZ:AV0Z5020903 Keywords : cd34 * sirp * b cell Subject RIV: EC - Immunology Impact factor: 1.652, year: 2003

  5. DNA flow cytometric analysis in variable types of hydropic placentas

    Directory of Open Access Journals (Sweden)

    Fatemeh Atabaki pasdar

    2015-05-01

    Full Text Available Background: Differential diagnosis between complete hydatidiform mole, partial hydatidiform mole and hydropic abortion, known as hydropic placentas is still a challenge for pathologists but it is very important for patient management. Objective: We analyzed the nuclear DNA content of various types of hydropic placentas by flowcytometry. Materials and Methods: DNA ploidy analysis was performed in 20 non-molar (hydropic and non-hydropic spontaneous abortions and 20 molar (complete and partial moles, formalin-fixed, paraffin-embedded tissue samples by flow cytometry. The criteria for selection were based on the histopathologic diagnosis. Results: Of 10 cases histologically diagnosed as complete hydatiform mole, 9 cases yielded diploid histograms, and 1 case was tetraploid. Of 10 partial hydatidiform moles, 8 were triploid and 2 were diploid. All of 20 cases diagnosed as spontaneous abortions (hydropic and non-hydropic yielded diploid histograms. Conclusion: These findings signify the importance of the combined use of conventional histology and ploidy analysis in the differential diagnosis of complete hydatidiform mole, partial hydatidiform mole and hydropic abortion.

  6. A novel flow cytometric HTS assay reveals functional modulators of ATP binding cassette transporter ABCB6.

    Directory of Open Access Journals (Sweden)

    Kishore Polireddy

    Full Text Available ABCB6 is a member of the adenosine triphosphate (ATP-binding cassette family of transporter proteins that is increasingly recognized as a relevant physiological and therapeutic target. Evaluation of modulators of ABCB6 activity would pave the way toward a more complete understanding of the significance of this transport process in tumor cell growth, proliferation and therapy-related drug resistance. In addition, this effort would improve our understanding of the function of ABCB6 in normal physiology with respect to heme biosynthesis, and cellular adaptation to metabolic demand and stress responses. To search for modulators of ABCB6, we developed a novel cell-based approach that, in combination with flow cytometric high-throughput screening (HTS, can be used to identify functional modulators of ABCB6. Accumulation of protoporphyrin, a fluorescent molecule, in wild-type ABCB6 expressing K562 cells, forms the basis of the HTS assay. Screening the Prestwick Chemical Library employing the HTS assay identified four compounds, benzethonium chloride, verteporfin, tomatine hydrochloride and piperlongumine, that reduced ABCB6 mediated cellular porphyrin levels. Validation of the identified compounds employing the hemin-agarose affinity chromatography and mitochondrial transport assays demonstrated that three out of the four compounds were capable of inhibiting ABCB6 mediated hemin transport into isolated mitochondria. However, only verteporfin and tomatine hydrochloride inhibited ABCB6's ability to compete with hemin as an ABCB6 substrate. This assay is therefore sensitive, robust, and suitable for automation in a high-throughput environment as demonstrated by our identification of selective functional modulators of ABCB6. Application of this assay to other libraries of synthetic compounds and natural products is expected to identify novel modulators of ABCB6 activity.

  7. FLOW CYTOMETRIC APPLICABILITY OF FLUORESCENT VITALITY PROBES ON PHYTOPLANKTON1.

    Science.gov (United States)

    Peperzak, Louis; Brussaard, Corina P D

    2011-06-01

    The applicability of six fluorescent probes (four esterase probes: acetoxymethyl ester of Calcein [Calcein-AM], 5-chloromethylfluorescein diacetate [CMFDA], fluorescein diacetate [FDA], and 2',7'-dichlorofluorescein diacetate [H 2 DCFDA]; and two membrane probes: bis-(1,3-dibutylbarbituric acid) trimethine oxonol [DiBAC 4 (3)] and SYTOX-Green) as vitality stains was tested on live and killed cells of 40 phytoplankton strains in exponential and stationary growth phases, belonging to 12 classes and consisting of four cold-water, 26 temperate, and four warm-water species. The combined live/dead ratios of all six probes indicated significant differences between the 12 plankton classes (P live/dead ratios of FDA and CMFDA were not significantly different from each other, and both performed better than Calcein-AM and H 2 DCFDA (P live/dead ratios) among all six probes belonged to nine genera from six classes of phytoplankton. In conclusion, FDA, CMFDA, DIBAC 4 (3), and SYTOX-Green represent a wide choice of vitality probes in the study of phytoplankton ecology, applicable in many species from different algal classes, originating from different regions and at different stages of growth. © 2011 Phycological Society of America.

  8. Flow cytometric analysis of circulating platelet-monocyte aggregates in whole blood: methodological considerations.

    Science.gov (United States)

    Harding, Scott A; Din, Jehangir N; Sarma, Jaydeep; Jessop, Alasdair; Weatherall, Mark; Fox, Keith A A; Newby, David E

    2007-08-01

    Platelet-monocyte aggregates are increasingly being used to quantify platelet activation. The variables that influence platelet-monocyte aggregates have not been well defined. We sought to determine the effect of blood collection, handling and processing techniques on detected levels of platelet-monocyte aggregates using a flow cytometric assay. Whole blood was labelled with anti-CD14-PE and anti-CD42a-FITC. Thereafter, samples were fixed and red cells lysed. Analysis was performed with the flow cytometer initially triggering on light scatter and then on FL-2 to identify CD14-PE positive monocytes. Platelet-monocyte aggregates were defined as monocytes positive for CD42a. The effect of collection, handling and processing techniques on this assay were assessed. Anticoagulation with heparin (20.1 +/- 2.0%), PPACK (16.8 +/- 1.9%), sodium citrate (12.3 +/- 1.6%) and EDTA (9.5 +/- 1.0%) resulted in markedly different levels of platelet-monocyte aggregation (P venepuncture (20.9 +/- 3.9% vs.13.8 +/- 2.4%, P = 0.03). For every 10 minutes of delay prior to processing platelet-monocyte aggregates increased by 2.8% (P = 0.0001) in PPACK anticoagulated blood and 1.7% (P = 0.01) in citrate anticoagulated blood. Erythrocyte lysis together with fixation does not affect platelet-monocyte aggregation. Platelet-monocyte aggregates remained stable over 24 hours when fixed and stored at 4 degrees C. Multiple handling and processing factors may affect platelet-monocyte aggregation. We recommend the measurement of platelet-monocyte aggregates on samples collected by direct venepuncture, using a direct thrombin inhibitor as the anticoagulant and minimising the time delay before sample fixation.

  9. Flow cytometric of reticulocytes quantification: radio-induction medullary aplasia application

    International Nuclear Information System (INIS)

    Dubner, D.; Perez, M.; Gisone, P.

    1996-01-01

    Flow cytometric reticulocyte quantification was assayed in ten patients undergoing bone marrow transplantation (BMT) with previous conditioning by chemotherapy and total body irradiation. A reticulocyte maturity index (RMI) was determined taking into account the RNA content. With the aim of testing the utility of RMI as an early predictor of functional recovery in marrow aplasia, other hematological indicators as neutrophils count were comparatively evaluated. Mean time elapsed between BMT and engraftment evidence by RMI was 17,6 days. In six patients the RMI was the earliest indicator of functional recovery. The applicability of this assay in the pursuit of radioinduced bone marrow aplasia is discussed. (authors). 4 refs., 4 figs., 2 tabs

  10. Karyological and flow cytometric evidence of triploid specimens in Bufo viridis (Amphibia Anura

    Directory of Open Access Journals (Sweden)

    D Cavallo

    2010-01-01

    Full Text Available Karyological and flow cytometric (FCM analyses were performed on a group of 14 green toads of the Bufo viridis species from seven Eurasian populations. Both approaches gave concordant results concerning the DNA ploidy level. All the populations examined were represented exclusively by diploid or tetraploid specimens, except one, where triploids were found. Results evidenced an interpopulation variability in DNA content against the same ploidy level, as well as an unusually high number of triploids in a particular reproductive place. The origin of polyploidy and the presence and persistence of a high number of triploids in a particular population are discussed.

  11. Flow cytometric evaluation of physico-chemical impact on Gram-positive and Gram-negative bacteria

    Directory of Open Access Journals (Sweden)

    Antje eFröhling

    2015-09-01

    Full Text Available Since heat sensitivity of fruits and vegetables limits the application of thermal inactivation processes, new emerging inactivation technologies have to be established to fulfil the requirements of food safety without affecting the produce quality. The efficiency of inactivation treatments has to be ensured and monitored. Monitoring of inactivation effects is commonly performed using traditional cultivation methods which have the disadvantage of the time span needed to obtain results.The aim of this study was to compare the inactivation effects of peracetic acid (PAA, ozonated water (O3 and cold atmospheric pressure plasma (CAPP on Gram-positive and Gram-negative bacteria using flow cytometric methods. E. coli cells were completely depolarized after treatment (15 s with 0.25 % PAA at 10 °C, and after treatment (10 s with 3.8 mg l-1 O3 at 12°C. The membrane potential of CAPP treated cells remained almost constant at an operating power of 20 W over a time period of 3 min, and subsequently decreased within 30 s of further treatment. Complete membrane permeabilization was observed after 10 s O3 treatment, but treatment with PAA and CAPP did not completely permeabilize the cells within 2 min and 4 min, respectively. Similar results were obtained for esterase activity. O3 inactivates cellular esterase but esterase activity was detected after 4 min CAPP treatment and 2 min PAA treatment. L. innocua cells and P. carotovorum cells were also permeabilized instantaneously by O3 treatment at concentrations of 3.8 ± 1 mg l-1. However, higher membrane permeabilization of L. innocua and P. carotovorum than of E. coli was observed at CAPP treatment of 20 W. The degree of bacterial damage due to the inactivation processes is highly dependent on treatment parameters as well as on treated bacteria. Important information regarding the inactivation mechanisms can be obtained by flow cytometric measurements and this enables the definition of critical process

  12. Immuno-flow cytometric detection of the ichthyotoxic dinoflagellates Gyrodinium aureolum and Gymnodinium nagasakiense: independence of physiological state

    Science.gov (United States)

    Vrieling, Engel G.; van de Poll, Willem H.; Vriezekolk, Gertie; Gieskes, Winfried W. C.

    1997-05-01

    The ichthyotoxic dinoflagellates Gyrodinium aureolum and Gymnodinium nagasakiense were cultured under different environmental conditions to test possible variability in immunochemical labelling intensity of cell-surface antigens using species-specific monoclonal antibodies. Variation of antigen abundance (which is directly related to labelling intensity) at the cell surface, determined by immuno-flow cytometry of cells labelled with FITC, appeared to be small but significant compared to control cultures. In general, a minor decrease in FIX fluorescence was recorded during exponential growth, followed by an increase during stationary growth. FITC fluorescence was correlated with cell size, shape and structure. This suggests a constant number of antigens per unit of cell surface. In all cultures, immunochemically labelled cells were distinguished clearly from unlabelled cells; immuno-flow cytometric identification is apparently not affected by growth conditions. Only at the end of the stationary growth phase in batch cultures did the FITC fluorescence values drop, which suggests that unhealthy, dying or lysing cells may either alter the composition of the cell surface or just fail to express the antigen.

  13. A flow cytometric assay technology based on quantum dots-encoded beads

    International Nuclear Information System (INIS)

    Wang Haiqiao; Liu Tiancai; Cao Yuancheng; Huang Zhenli; Wang Jianhao; Li Xiuqing; Zhao Yuandi

    2006-01-01

    A flow cytometric detecting technology based on quantum dots (QDs)-encoded beads has been described. Using this technology, several QDs-encoded beads with different code were identified effectively, and the target molecule (DNA sequence) in solution was also detected accurately by coupling to its complementary sequence probed on QDs-encoded beads through DNA hybridization assay. The resolution of this technology for encoded beads is resulted from two longer wavelength fluorescence identification signals (yellow and red fluorescent signals of QDs), and the third shorter wavelength fluorescence signal (green reporting signal of fluorescein isothiocyanate (FITC)) for the determination of reaction between probe and target. In experiment, because of QDs' unique optical character, only one excitation light source was needed to excite the QDs and probe dye FITC synchronously comparing with other flow cytometric assay technology. The results show that this technology has present excellent repeatability and good accuracy. It will become a promising multiple assay platform in various application fields after further improvement

  14. Detection of nickel and palladium contact hypersensitivity by a flow cytometric lymphocyte proliferation test.

    Science.gov (United States)

    Spoerri, I; Scherer, K; Michel, S; Link, S; Bircher, A J; Heijnen, I A F M

    2015-03-01

    We established a flow cytometric lymphocyte proliferation test (LPT) for the detection of nickel (Ni) and palladium (Pd) sensitization. Eighty-one consecutive patients with an indication for patch test (PT) were tested by LPT with Ni (NiSO4 ) and Pd (Na2 PdCl4 and PdCl2 ) salts. The imprecision of the LPT was low (coefficient of variation 7.2%). Using PT as a diagnostic reference, the sensitivity and specificity of LPT were 74.4% and 80% for NiSO4 , 74.4% and 78.3% for Na2 PdCl4 , and 57.2% and 85.4% for PdCl2 , respectively. For both Ni and Pd, the likelihood ratio for a positive PT markedly increased with increasing LPT value. With medical history as a reference, the sensitivity and specificity were 40.6% and 82.1% for LPT and 59.4% and 89.7% for PT, respectively. Combination of LPT and PT resulted in a higher specificity of 95%, albeit lower sensitivity of 34.4%. In conclusion, flow cytometric LPT represents a reliable and useful method for the detection of Ni and Pd sensitization. LPT values correlate with PT results and, when used in combination with PT, increase test specificity. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. A flow cytometric protocol for titering recombinant adenoviral vectors containing the green fluorescent protein.

    Science.gov (United States)

    Hitt, D C; Booth, J L; Dandapani, V; Pennington, L R; Gimble, J M; Metcalf, J

    2000-03-01

    As the use of adenoviral vectors in gene therapy protocols increases, there is a corresponding need for rapid, accurate, and reproducible titer methods. Multiple methods currently exist for determining titers of recombinant adenoviral vector, including optical absorbance, electron microscopy, fluorescent focus assay, and the "gold standard" plaque assay. This paper introduces a novel flow cytometric method for direct titer determination that relies on the expression of the green fluorescent protein (GFP), a tracking marker incorporated into several adenoviral vectors. This approach was compared to the plaque assay using 10(-4)- to 10(-6)-fold dilutions of a cesium-chloride-purified, GFP expressing adenovirus (AdEasy + GFP + GAL). The two approaches yielded similar titers: 3.25 +/- 1.85 x 10(9) PFU/mL versus 3.46 +/- 0.76 x 10(9) green fluorescent units/(gfu/mL). The flow cytometric method is complete within 24 h in contrast to the 7 x 10 days required by the plaque assay. These results indicate that the GFU/mL is an alternative functional titer method for fluorescent-tagged adenoviral vectors.

  16. Vertical and longitudinal gradients in HNA-LNA cell abundances and cytometric characteristics in the Mediterranean Sea

    Directory of Open Access Journals (Sweden)

    F. Van Wambeke

    2011-07-01

    Full Text Available Heterotrophic bacterioplankton abundance and production were investigated with depth (down to bathypelagic layers and with longitude (from 4.9° E to 32.7° E along a cruise track across the Mediterranean Sea in early summer 2008. Abundances and flow cytometric characteristics (green fluorescence and side scatter signals of high nucleic acid (HNA and low nucleic acid (LNA bacterial cells were determined using flow cytometry. Contrary to what is generally observed, the relative importance of HNA cells, as a percent of total cells, (%HNA, range 30–69 % was inversely related to bacterial production (range 0.15–44 ng C l−1 h−1 although the negative relation was weak (log–log regression r2=0.19. The %HNA as well as the mean side scatter of HNA group increased significantly with depth in the meso and bathypelagic layers. Vertical stratification played an important role in influencing the distribution and characteristics of bacterial cells especially with regard to layers located above, within or below the deep chlorophyll maximum. Within a given layer, the relationships between the flow cytometric characteristics and environmental variables such as chlorophyll-a, nutrients or bacterial production changed. Overall, the relationships between HNA and LNA cells and environmental parameters differed vertically more than longitudinally.

  17. Flow cytometric-membrane potential detection of sodium channel active marine toxins: application to ciguatoxins in fish muscle and feasibility of automating saxitoxin detection.

    Science.gov (United States)

    Manger, Ronald; Woodle, Doug; Berger, Andrew; Dickey, Robert W; Jester, Edward; Yasumoto, Takeshi; Lewis, Richard; Hawryluk, Timothy; Hungerford, James

    2014-01-01

    Ciguatoxins are potent neurotoxins with a significant public health impact. Cytotoxicity assays have allowed the most sensitive means of detection of ciguatoxin-like activity without reliance on mouse bioassays and have been invaluable in studying outbreaks. An improvement of these cell-based assays is presented here in which rapid flow cytometric detection of ciguatoxins and saxitoxins is demonstrated using fluorescent voltage sensitive dyes. A depolarization response can be detected directly due to ciguatoxin alone; however, an approximate 1000-fold increase in sensitivity is observed in the presence of veratridine. These results demonstrate that flow cytometric assessment of ciguatoxins is possible at levels approaching the trace detection limits of our earlier cytotoxicity assays, however, with a significant reduction in analysis time. Preliminary results are also presented for detection of brevetoxins and for automation and throughput improvements to a previously described method for detecting saxitoxins in shellfish extracts.

  18. Multiplex competitive microbead-based flow cytometric immunoassay using quantum dot fluorescent labels

    International Nuclear Information System (INIS)

    Yu, Hye-Weon; Kim, In S.; Niessner, Reinhard; Knopp, Dietmar

    2012-01-01

    Highlights: ► First time, duplex competitive bead-based flow cytometric immunoassay was developed using ODs. ► Antibody-coated QD detection probes and antigen-immobilized microspheres were synthesized. ► The two model target analytes were low molecular weight compounds of microbial and chemical origin. ► The determination of different water types was possible after simple filtration of samples. - Abstract: In answer to the ever-increasing need to perform the simultaneous analysis of environmental hazards, microcarrier-based multiplex technologies show great promise. Further integration with biofunctionalized quantum dots (QDs) creates new opportunities to extend the capabilities of multicolor flow cytometry with their unique fluorescence properties. Here, we have developed a competitive microbead-based flow cytometric immunoassay using QDs fluorescent labels for simultaneous detection of two analytes, bringing the benefits of sensitive, rapid and easy-of-manipulation analytical tool for environmental contaminants. As model target compounds, the cyanobacterial toxin microcystin-LR and the polycyclic aromatic hydrocarbon compound benzo[a]pyrene were selected. The assay was carried out in two steps: the competitive immunological reaction of multiple targets using their exclusive sensing elements of QD/antibody detection probes and antigen-coated microsphere, and the subsequent flow cytometric analysis. The fluorescence of the QD-encoded microsphere was thus found to be inversely proportional to target analyte concentration. Under optimized conditions, the proposed assay performed well within 30 min for the identification and quantitative analysis of the two environmental contaminants. For microcystin-LR and benzo[a]pyrene, dose–response curves with IC 50 values of 5 μg L −1 and 1.1 μg L −1 and dynamic ranges of 0.52–30 μg L −1 and 0.13–10 μg L −1 were obtained, respectively. Recovery was 92.6–106.5% for 5 types of water samples like bottled

  19. Flow cytometric analysis of mitotic cycle perturbation by chemical carcinogens in cultured epithelial cells. [Effects of benzo(a)pyrene-diol-epoxide on mitotic cycle of cultural mouse liver epithelial cells

    Energy Technology Data Exchange (ETDEWEB)

    Pearlman, Andrew Leonard [Univ. of California, Berkeley, CA (United States)

    1978-08-01

    A system for kinetic analysis of mitotic cycle perturbation by various agents was developed and applied to the study of the mitotic cycle effects and dependency of the chemical carcinogen benzo(a)pyrene-diolepoxide, DE, upon a mouse lever epithelial cell line, NMuLi. The study suggests that the targets of DE action are not confined to DNA alone but may include cytoplasmic structures as well. DE was found to affect cells located in virtually every phase of the mitotic cycle, with cells that were actively synthesizing DNA showing the strongest response. However, the resulting perturbations were not confined to S-phase alone. DE slowed traversal through S-phase by about 40% regardless of the cycle phase of the cells exposed to it, and slowed traversal through G2M by about 50%. When added to G1 cells, DE delayed recruitment of apparently quiescent (G0) cells by 2 hours, and reduced the synchrony of the cohort of cells recruited into active proliferation. The kinetic analysis system consists of four elements: tissue culture methods for propagating and harvesting cell populations; an elutriation centrifugation system for bulk synchronization of cells in various phases of the mitotic cycle; a flow cytometer (FCM), coupled with appropriate staining protocols, to enable rapid analysis of the DNA distribution of any given cell population; and data reduction and analysis methods for extracting information from the DNA histograms produced by the FCM. The elements of the system are discussed. A mathematical analysis of DNA histograms obtained by FCM is presented. The analysis leads to the detailed implementation of a new modeling approach. The new modeling approach is applied to the estimation of cell cycle kinetic parameters from time series of DNA histograms, and methods for the reduction and interpretation of such series are suggested.

  20. CD33 monoclonal antibody conjugated Au cluster nano-bioprobe for targeted flow-cytometric detection of acute myeloid leukaemia

    Energy Technology Data Exchange (ETDEWEB)

    Retnakumari, Archana; Jayasimhan, Jasusri; Chandran, Parwathy; Menon, Deepthy; Nair, Shantikumar; Mony, Ullas; Koyakutty, Manzoor, E-mail: manzoork@aims.amrita.edu, E-mail: ullasmony@aims.amrita.edu [Amrita Centre for Nanoscience and Molecular Medicine, Amrita Institute of Medical Science, Cochin 682 041 (India)

    2011-07-15

    Protein stabilized gold nanoclusters (Au-NCs) are biocompatible, near-infrared (NIR) emitting nanosystems having a wide range of biomedical applications. Here, we report the development of a Au-NC based targeted fluorescent nano-bioprobe for the flow-cytometric detection of acute myeloid leukaemia (AML) cells. Au-NCs with {approx} 25-28 atoms showing bright red-NIR fluorescence (600-750 nm) and average size of {approx} 0.8 nm were prepared by bovine serum albumin assisted reduction-cum-stabilization in aqueous phase. The protein protected clusters were conjugated with monoclonal antibody against CD33 myeloid antigen, which is overexpressed in {approx} 99.2% of the primitive population of AML cells, as confirmed by immunophenotyping using flow cytometry. Au-NC-CD33 conjugates having average size of {approx} 12 nm retained bright fluorescence over an extended duration of {approx} a year, as the albumin protein protects Au-NCs against degradation. Nanotoxicity studies revealed excellent biocompatibility of Au-NC conjugates, as they showed no adverse effect on the cell viability and inflammatory response. Target specificity of the conjugates for detecting CD33 expressing AML cells (KG1a) in flow cytometry showed specific staining of {approx} 95.4% of leukaemia cells within 1-2 h compared to a non-specific uptake of {approx} 8.2% in human peripheral blood cells (PBMCs) which are CD33{sup low}. The confocal imaging also demonstrated the targeted uptake of CD33 conjugated Au-NCs by leukaemia cells, thus confirming the flow cytometry results. This study demonstrates that novel nano-bioprobes can be developed using protein protected fluorescent nanoclusters of Au for the molecular receptor targeted flow cytometry based detection and imaging of cancer cells.

  1. CD33 monoclonal antibody conjugated Au cluster nano-bioprobe for targeted flow-cytometric detection of acute myeloid leukaemia

    Science.gov (United States)

    Retnakumari, Archana; Jayasimhan, Jasusri; Chandran, Parwathy; Menon, Deepthy; Nair, Shantikumar; Mony, Ullas; Koyakutty, Manzoor

    2011-07-01

    Protein stabilized gold nanoclusters (Au-NCs) are biocompatible, near-infrared (NIR) emitting nanosystems having a wide range of biomedical applications. Here, we report the development of a Au-NC based targeted fluorescent nano-bioprobe for the flow-cytometric detection of acute myeloid leukaemia (AML) cells. Au-NCs with ~ 25-28 atoms showing bright red-NIR fluorescence (600-750 nm) and average size of ~ 0.8 nm were prepared by bovine serum albumin assisted reduction-cum-stabilization in aqueous phase. The protein protected clusters were conjugated with monoclonal antibody against CD33 myeloid antigen, which is overexpressed in ~ 99.2% of the primitive population of AML cells, as confirmed by immunophenotyping using flow cytometry. Au-NC-CD33 conjugates having average size of ~ 12 nm retained bright fluorescence over an extended duration of ~ a year, as the albumin protein protects Au-NCs against degradation. Nanotoxicity studies revealed excellent biocompatibility of Au-NC conjugates, as they showed no adverse effect on the cell viability and inflammatory response. Target specificity of the conjugates for detecting CD33 expressing AML cells (KG1a) in flow cytometry showed specific staining of ~ 95.4% of leukaemia cells within 1-2 h compared to a non-specific uptake of ~ 8.2% in human peripheral blood cells (PBMCs) which are CD33low. The confocal imaging also demonstrated the targeted uptake of CD33 conjugated Au-NCs by leukaemia cells, thus confirming the flow cytometry results. This study demonstrates that novel nano-bioprobes can be developed using protein protected fluorescent nanoclusters of Au for the molecular receptor targeted flow cytometry based detection and imaging of cancer cells.

  2. CD33 monoclonal antibody conjugated Au cluster nano-bioprobe for targeted flow-cytometric detection of acute myeloid leukaemia

    International Nuclear Information System (INIS)

    Retnakumari, Archana; Jayasimhan, Jasusri; Chandran, Parwathy; Menon, Deepthy; Nair, Shantikumar; Mony, Ullas; Koyakutty, Manzoor

    2011-01-01

    Protein stabilized gold nanoclusters (Au-NCs) are biocompatible, near-infrared (NIR) emitting nanosystems having a wide range of biomedical applications. Here, we report the development of a Au-NC based targeted fluorescent nano-bioprobe for the flow-cytometric detection of acute myeloid leukaemia (AML) cells. Au-NCs with ∼ 25-28 atoms showing bright red-NIR fluorescence (600-750 nm) and average size of ∼ 0.8 nm were prepared by bovine serum albumin assisted reduction-cum-stabilization in aqueous phase. The protein protected clusters were conjugated with monoclonal antibody against CD33 myeloid antigen, which is overexpressed in ∼ 99.2% of the primitive population of AML cells, as confirmed by immunophenotyping using flow cytometry. Au-NC-CD33 conjugates having average size of ∼ 12 nm retained bright fluorescence over an extended duration of ∼ a year, as the albumin protein protects Au-NCs against degradation. Nanotoxicity studies revealed excellent biocompatibility of Au-NC conjugates, as they showed no adverse effect on the cell viability and inflammatory response. Target specificity of the conjugates for detecting CD33 expressing AML cells (KG1a) in flow cytometry showed specific staining of ∼ 95.4% of leukaemia cells within 1-2 h compared to a non-specific uptake of ∼ 8.2% in human peripheral blood cells (PBMCs) which are CD33 low . The confocal imaging also demonstrated the targeted uptake of CD33 conjugated Au-NCs by leukaemia cells, thus confirming the flow cytometry results. This study demonstrates that novel nano-bioprobes can be developed using protein protected fluorescent nanoclusters of Au for the molecular receptor targeted flow cytometry based detection and imaging of cancer cells.

  3. Bivariate flow cytometric analysis and sorting of different types of maize starch grains.

    Science.gov (United States)

    Zhang, Xudong; Feng, Jiaojiao; Wang, Heng; Zhu, Jianchu; Zhong, Yuyue; Liu, Linsan; Xu, Shutu; Zhang, Renhe; Zhang, Xinghua; Xue, Jiquan; Guo, Dongwei

    2018-02-01

    Particle-size distribution, granular structure, and composition significantly affect the physicochemical properties, rheological properties, and nutritional function of starch. Flow cytometry and flow sorting are widely considered convenient and efficient ways of classifying and separating natural biological particles or other substances into subpopulations, respectively, based on the differential response of each component to stimulation by a light beam; the results allow for the correlation analysis of parameters. In this study, different types of starches isolated from waxy maize, sweet maize, high-amylose maize, pop maize, and normal maize were initially classified into various subgroups by flow cytometer and then collected through flow sorting to observe their morphology and particle-size distribution. The results showed that a 0.25% Gelzan solution served as an optimal reagent for keeping individual starch particles homogeneously dispersed in suspension for a relatively long time. The bivariate flow cytometric population distributions indicated that the starches of normal maize, sweet maize, and pop maize were divided into two subgroups, whereas high-amylose maize starch had only one subgroup. Waxy maize starch, conversely, showed three subpopulations. The subgroups sorted by flow cytometer were determined and verified in terms of morphology and granule size by scanning electron microscopy and laser particle distribution analyzer. Results showed that flow cytometry can be regarded as a novel method for classifying and sorting starch granules. © 2017 International Society for Advancement of Cytometry. © 2017 International Society for Advancement of Cytometry.

  4. Laser-based flow cytometric analysis of genotoxicity of humans exposed to ionizing radiation during the Chernobyl accident

    Science.gov (United States)

    Jensen, Ronald H.; Bigbee, William L.; Langlois, Richard G.; Grant, Stephen G.; Pleshanov, Pavel G.; Chirkov, Andre A.; Pilinskaya, Maria A.

    1991-05-01

    An analytical technique has been developed that allows laser-based flow cytometric measurement of the frequency of red blood cells that have lost allele-specific expression of a cell surface antigen due to genetic toxicity in bone marrow precursor cells. Previous studies demonstrated a correlation of such effects with the exposure of each individual to mutagenic phenomena, such as ionizing radiation, and the effects can persist for the lifetime of each individual. During the emergency response to the nuclear power plant accidert at Chemobyl, Ukraine, USSR, a number of people were exposed to whole body doses of ioniing radiation. Some of these individuals were tested with this laser-based assay and found to express a dose-dependent increase in the frequency of variant red blood cells that appears to be a persistent biological effect. This effect is similar to that which was previously observed in individuals who were exposed to ionizing radiation at Hiroshima in 1945 because of the A-bomb explosion. All data indicate that this assay might well be used as a biodosimeter to estimate radiation dose and also as an element to be used for estimating the risk of each individual to develop cancer due to radiation exposure.

  5. Flow cytometric analysis using SYBR Green I for genome size estimation in coffee.

    Science.gov (United States)

    Ronildo Clarindo, Wellington; Roberto Carvalho, Carlos

    2011-02-01

    Plant genome size has been measured by flow cytometry using propidium iodide as a dye for nuclear DNA staining. However, some authors have reported the occurrence of genome size estimation errors, especially in plants rich in secondary metabolites, such as the coffee tree. In this context, we tested an alternative cytometric protocol using the SYBR Green I as a fluorochrome for stoichiometrically staining nuclear double-stranded DNA in Coffea canephora (2x) and Coffea arabica (4x). The results showed that the respective mean genome size measured from nuclei stained with SYBR Green I and propidium iodide was statistically identical. However, the G(0)/G(1) peaks of nuclei stained with SYBR Green I exhibited lower coefficient variations (1.57-2.85%) compared to those stained with propidium iodide (2.75-4.80%). Coefficient variation statistical data suggest that SYBR Green I is adequate for stoichiometric nuclei staining using this methodology. Our results provide evidence that SYBR Green I can be used in flow cytometry measurements of plants, with the advantages of minimizing errors in nuclear DNA content quantification, staining relatively quicker, with high affinity, and being less mutagenic than propidium iodide. Copyright © 2009 Elsevier GmbH. All rights reserved.

  6. Flow cytometric analysis of lymphocyte proliferative responses to food allergens in dogs with food allergy.

    Science.gov (United States)

    Fujimura, Masato; Masuda, Kenichi; Hayashiya, Makio; Okayama, Taro

    2011-10-01

    Two different allergy tests, antigen-specific immunoglobulin E quantification (IgE test) and flow cytometric analysis of antigen-specific proliferation of peripheral lymphocytes (lymphocyte proliferation test), were performed to examine differences in allergic reactions to food allergens in dogs with food allergy (FA). Thirteen dogs were diagnosed as FA based on clinical findings and elimination diet trials. Seven dogs clinically diagnosed with canine atopic dermatitis (CAD) were used as a disease control group, and 5 healthy dogs were used as a negative control group. In the FA group, 19 and 33 allergen reactions were identified using the serum IgE test and the lymphocyte proliferation test, respectively. Likewise, in the CAD group, 12 and 6 allergen reactions and in the healthy dogs 3 and 0 allergen reactions were identified by each test, respectively. A significant difference was found between FA and healthy dogs in terms of positive allergen detection by the lymphocyte proliferation test, suggesting that the test can be useful to differentiate FA from healthy dogs but not from CAD. Both tests were repeated in 6 of the dogs with FA after a 1.5- to 5-month elimination diet trial. The IgE concentrations in 9 of 11 of the positive reactions decreased by 20-80%, whereas all the positive reactions in the lymphocyte proliferation test decreased to nearly zero (Pfood allergens may be involved in the pathogenesis of canine FA.

  7. Flow cytometric characterization of peripheral blood leukocyte populations of 3 neotropical snake species: Boa constrictor, Bothrops jararaca, and Crotalus durissus.

    Science.gov (United States)

    Carvalho, Marcelo P N; Queiroz-Hazarbassanov, Nicolle G T; Massoco, Cristina O; Rossi, Silmara; Sant'Anna, Sávio S; Catão-Dias, José L; Grego, Kathleen F

    2016-06-01

    The reptilian immune system is represented by innate, humoral, and cell-mediated mechanisms, involving different types of blood leukocytes. The development of optimized methods for the advanced study of origin and function of reptilian blood leukocytes is needed. The purpose of the study was to optimize leukocyte density gradient isolation protocols from snake peripheral blood samples, and characterize recovered cells by flow cytometry based on size and internal complexity for a qualitative and semi-quantitative assessment of leukocyte populations in one boa (Boa constrictor), and 2 viper species (Bothrops jararaca, Crotalus durissus). Blood samples from 30 snakes (10 from each species, 5 males and 5 females) were collected in tubes with sodium heparin. Fresh blood was centrifuged with either ficoll-paque PLUS or percoll density gradients for leukocyte isolation. Flow cytometric leukocyte gates were defined based on size (forward scatter [FSC]) and internal complexity (side scatter [SSC]). Relative leukocyte differential counts after sorting the cells in these gates in one snake for each species were compared to conventional light microscopic differential counts on unsorted isolated leukocytes. There was no statistical difference in the relative leukocyte populations, including heterophils, azurophils, and small and large lymphocytes between samples isolated by ficoll or percoll. Four leukocyte gates were identified based on their location in FSC/SSC cytograms. The relative leukocyte differential counts after sorting in single animals showed some agreement with the light microscopy differential count on unsorted cells. Based on FSC and SSC, 4 distinct leukocyte populations were found in ficoll or percoll density gradient isolated leukocytes from peripheral blood from boa and viper species. Further optimization of the technique should allow the performance of functional assays. © 2016 American Society for Veterinary Clinical Pathology.

  8. The evaluation of histo-blood group ABO typing by flow cytometric and PCR-amplification of specific alleles analyses and their application in clinical laboratories.

    Science.gov (United States)

    Aki, Kensaku; Izumi, Azusa; Hosoi, Eiji

    2012-01-01

    ABO antigens are oligosaccharide antigens, and are widely distributed on red blood and tissue cells as well as in saliva and body fluid. Therefore, these antigens are important not only for blood transfusion, but also for tissue cell and organ transplantations. Also, blood, hair, and seminal fluid are important sources of evidence at crime scenes, and these antigens are some of the most important markers for personal identification in forensic investigations. Here, we describe the development and use of quantitative analysis of A, B, and H antigens on red blood cells by employing flow cytometric analysis and the ABO genotyping method based on PCR-amplification of specific alleles (PASA) within DNA, especially from blood and saliva. In this study, flow cytometric analysis could be used to compare the differences between the expression of A and/or B and H antigens on red blood cells with various phenotypes, and the PASA method was able to determine the genotype of the type cisA(2)B(3) pedigree using only DNA extracted from saliva. These analysis methods are simple and useful for judging the ABO blood group system and genotyping, and are used widely throughout research and clinical laboratories and forensic fields.

  9. Flow cytometric analysis of viable bacteria in urine samples of febrile patients at the emergency department.

    Science.gov (United States)

    Tavenier, Anne H; de Boer, Foppie J; Moshaver, Bijan; van der Leur, Sjef J C M; Stegeman, Coen A; Groeneveld, Paul H P

    2017-08-16

    Fast and reliable diagnostics are important in febrile patients admitted to the emergency department. Current urine diagnostics are fast but moderately reliable or reliable but time consuming. Flow cytometry (FC) is a new promising technique in the diagnostics of complicated urinary tract infections by counting bacteria in urine samples. The aim of this study is to improve the FC method by counting only viable bacteria. Urine was obtained from 135 consecutive febrile patients at the emergency department. According to protocol regular diagnostic urine tests were performed. In addition, FC counting of viable and non-viable bacteria was executed after staining with thiazole orange and propidium iodide. All test results were compared to the results of urine culture (≥ 10 5 colony forming units/mL). At a cut-off value of 2.01 × 10 5 viable bacteria/mL the sensitivity was 100% and specificity was 78.4% (AUC-value 0.955 on ROC-curve). Spearman correlation test exhibited a higher correlation for flow cytometric counting of only viable bacteria than counting of all bacteria (0.59 vs. 0.37). Using ROC-curves, the AUC-values for FC counting of all bacteria, only viable bacteria and Gram staining were respectively 0.935, 0.955, and 0.968 (P > 0.05). FC counting of only viable bacteria can predict quickly and reliably positive and negative urine cultures in febrile patients admitted to the emergency department. It can help to improve the speed and accuracy of the diagnostic procedure at the emergency department. © 2017 Clinical Cytometry Society. © 2017 International Clinical Cytometry Society.

  10. Flow cytometric immunobead assay for quantitative detection of platelet autoantibodies in immune thrombocytopenia patients.

    Science.gov (United States)

    Zhai, Juping; Ding, Mengyuan; Yang, Tianjie; Zuo, Bin; Weng, Zhen; Zhao, Yunxiao; He, Jun; Wu, Qingyu; Ruan, Changgeng; He, Yang

    2017-10-23

    Platelet autoantibody detection is critical for immune thrombocytopenia (ITP) diagnosis and prognosis. Therefore, we aimed to establish a quantitative flow cytometric immunobead assay (FCIA) for ITP platelet autoantibodies evaluation. Capture microbeads coupled with anti-GPIX, -GPIb, -GPIIb, -GPIIIa and P-selectin antibodies were used to bind the platelet-bound autoantibodies complex generated from plasma samples of 250 ITP patients, 163 non-ITP patients and 243 healthy controls, a fluorescein isothiocyanate (FITC)-conjugated secondary antibody was the detector reagent and mean fluorescence intensity (MFI) signals were recorded by flow cytometry. Intra- and inter-assay variations of the quantitative FCIA assay were assessed. Comparisons of the specificity, sensitivity and accuracy between quantitative and qualitative FCIA or monoclonal antibody immobilization of platelet antigen (MAIPA) assay were performed. Finally, treatment process was monitored by our quantitative FCIA in 8 newly diagnosed ITPs. The coefficient of variations (CV) of the quantitative FCIA assay were respectively 9.4, 3.8, 5.4, 5.1 and 5.8% for anti-GPIX, -GPIb, -GPIIIa, -GPIIb and -P-selectin autoantibodies. Elevated levels of autoantibodies against platelet glycoproteins GPIX, GPIb, GPIIIa, GPIIb and P-selectin were detected by our quantitative FCIA in ITP patients compared to non-ITP patients or healthy controls. The sensitivity, specificity and accuracy of our quantitative assay were respectively 73.13, 81.98 and 78.65% when combining all 5 autoantibodies, while the sensitivity, specificity and accuracy of MAIPA assay were respectively 41.46, 90.41 and 72.81%. A quantitative FCIA assay was established. Reduced levels of platelet autoantibodies could be confirmed by our quantitative FCIA in ITP patients after corticosteroid treatment. Our quantitative assay is not only good for ITP diagnosis but also for ITP treatment monitoring.

  11. Flow cytometric gating for spleen monocyte and DC subsets: differences in autoimmune NOD mice and with acute inflammation.

    Science.gov (United States)

    Dong, Matthew B; Rahman, M Jubayer; Tarbell, Kristin V

    2016-05-01

    The role of antigen presenting cells (APCs) in the pathogenesis of autoimmune and other inflammatory diseases is now better understood due to advances in multicolor flow cytometry, gene expression analysis of APC populations, and functional correlation of mouse to human APC populations. A simple but informative nomenclature of conventional and plasmacytoid dendritic cell subsets (cDC1, cDC2, pDC) and monocyte-derived populations incorporates these advances, but accurate subset identification is critical. Ambiguous gating schemes and alterations of cell surface markers in inflammatory condition can make comparing results between studies difficult. Both acute inflammation, such as TLR-ligand stimulation, and chronic inflammation as found in mouse models of autoimmunity can alter DC subset gating. Here, we address these issues using in vivo CpG stimulation as an example of acute inflammation and the non-obese diabetic (NOD) mouse as a model of chronic inflammation.We provide a flow cytometric antibody panel and gating scheme that differentiate 2 monocytic and 3DC subsets in the spleen both at steady state and after CpG stimulation. Using this method, we observed differences in the composition of NOD DCs that have been previously reported, and newly identified increases in the number of NOD monocyte-derived DCs. Finally, we established a protocol for DC phosphoflow to measure the phosphorylation state of intracellular proteins, and use it to confirm functional differences in the identified subsets. Therefore, we present optimized methods for distinguishing monocytic and DC populations with and without inflammation and/or autoimmunity associated with NOD mice. Published by Elsevier B.V.

  12. FlowFP: A Bioconductor Package for Fingerprinting Flow Cytometric Data

    Directory of Open Access Journals (Sweden)

    Wade T. Rogers

    2009-01-01

    Full Text Available A new software package called flowFP for the analysis of flow cytometry data is introduced. The package, which is tightly integrated with other Bioconductor software for analysis of flow cytometry, provides tools to transform raw flow cytometry data into a form suitable for direct input into conventional statistical analysis and empirical modeling software tools. The approach of flowFP is to generate a description of the multivariate probability distribution function of flow cytometry data in the form of a “fingerprint.” As such, it is independent of a presumptive functional form for the distribution, in contrast with model-based methods such as Gaussian Mixture Modeling. FlowFP is computationally efficient and able to handle extremely large flow cytometry data sets of arbitrary dimensionality. Algorithms and software implementation of the package are described. Use of the software is exemplified with applications to data quality control and to the automated classification of Acute Myeloid Leukemia.

  13. Flow Cytometric Evaluation of Human Neutrophil Apoptosis During Nitric Oxide Generation In Vitro: The Role of Exogenous Antioxidants

    Directory of Open Access Journals (Sweden)

    Zofia Sulowska

    2005-01-01

    in vitro. The effect of exogenous supply of NO donors such as SNP, SIN-1, and GEA-3162 on the course of human neutrophil apoptosis and the role of extracellular antioxidants in this process was investigated. Isolated from peripheral blood, neutrophils were cultured in the presence or absence of NO donor compounds and antioxidants for 8, 12, and 20 hours. Apoptosis of neutrophils was determined in vitro by flow cytometric analysis of cellular DNA content and Annexin V protein binding to the cell surface. Exposure of human neutrophils to GEA-3162 and SIN-1 significantly accelerates and enhances their apoptosis in vitro in a time-dependent fashion. In the presence of SNP, intensification of apoptosis has not been revealed until 12 hours after the culture. The inhibition of GEA-3162- and SIN-1-mediated neutrophil apoptosis by superoxide dismutase (SOD but not by catalase (CAT was observed. Our results show that SOD and CAT can protect neutrophils against NO-donors-induced apoptosis and suggest that the interaction of NO and oxygen metabolites signals may determine the destructive or protective role of NO donor compounds during apoptotic neutrophil death.

  14. Air sampling to assess potential generation of aerosolized viable bacteria during flow cytometric analysis of unfixed bacterial suspensions

    Science.gov (United States)

    Carson, Christine F; Inglis, Timothy JJ

    2018-01-01

    This study investigated aerosolized viable bacteria in a university research laboratory during operation of an acoustic-assisted flow cytometer for antimicrobial susceptibility testing by sampling room air before, during and after flow cytometer use. The aim was to assess the risk associated with use of an acoustic-assisted flow cytometer analyzing unfixed bacterial suspensions. Air sampling in a nearby clinical laboratory was conducted during the same period to provide context for the existing background of microorganisms that would be detected in the air. The three species of bacteria undergoing analysis by flow cytometer in the research laboratory were Klebsiella pneumoniae, Burkholderia thailandensis and Streptococcus pneumoniae. None of these was detected from multiple 1000 L air samples acquired in the research laboratory environment. The main cultured bacteria in both locations were skin commensal and environmental bacteria, presumed to have been disturbed or dispersed in laboratory air by personnel movements during routine laboratory activities. The concentrations of bacteria detected in research laboratory air samples were reduced after interventional cleaning measures were introduced and were lower than those in the diagnostic clinical microbiology laboratory. We conclude that our flow cytometric analyses of unfixed suspensions of K. pneumoniae, B. thailandensis and S. pneumoniae do not pose a risk to cytometer operators or other personnel in the laboratory but caution against extrapolation of our results to other bacteria and/or different flow cytometric experimental procedures. PMID:29608197

  15. Simple flow cytometric detection of haemozoin containing leukocytes and erythrocytes for research on diagnosis, immunology and drug sensitivity testing

    Directory of Open Access Journals (Sweden)

    Grobusch Martin P

    2011-03-01

    Full Text Available Abstract Background Malaria pigment (haemozoin, Hz has been the focus of diverse research efforts. However, identification of Hz-containing leukocytes or parasitized erythrocytes is usually based on microscopy, with inherent limitations. Flow cytometric detection of depolarized Side-Scatter is more accurate and its adaptation to common bench top flow cytometers might allow several applications. These can range from the ex-vivo and in-vitro detection and functional analysis of Hz-containing leukocytes to the detection of parasitized Red-Blood-Cells (pRBCs to assess antimalarial activity. Methods A standard benchtop flow cytometer was adapted to detect depolarized Side-Scatter. Synthetic and Plasmodium falciparum Hz were incubated with whole blood and PBMCs to detect Hz-containing leukocytes and CD16 expression on monocytes. C5BL/6 mice were infected with Plasmodium berghei ANKA or P. berghei NK65 and Hz-containing leukocytes were analysed using CD11b and Gr1 expression. Parasitized RBC from infected mice were identified using anti-Ter119 and SYBR green I and were analysed for depolarized Side Scatter. A highly depolarizing RBC population was monitored in an in-vitro culture incubated with chloroquine or quinine. Results A flow cytometer can be easily adapted to detect depolarized Side-Scatter and thus, intracellular Hz. The detection and counting of Hz containing leukocytes in fresh human or mouse blood, as well as in leukocytes from in-vitro experiments was rapid and easy. Analysis of CD14/CD16 and CD11b/Gr1 monocyte expression in human or mouse blood, in a mixed populations of Hz-containing and non-containing monocytes, appears to show distinct patterns in both types of cells. Hz-containing pRBC and different maturation stages could be detected in blood from infected mice. The analysis of a highly depolarizing population that contained mature pRBC allowed to assess the effect of chloroquine and quinine after only 2 and 4 hours, respectively

  16. Functional and cytometric examination of different human lung epithelial cell types as drug transport barriers.

    Science.gov (United States)

    Min, Kyoung Ah; Rosania, Gus R; Kim, Chong-Kook; Shin, Meong Cheol

    2016-03-01

    To develop inhaled medications, various cell culture models have been used to examine the transcellular transport or cellular uptake properties of small molecules. For the reproducible high throughput screening of the inhaled drug candidates, a further verification of cell architectures as drug transport barriers can contribute to establishing appropriate in vitro cell models. In the present study, side-by-side experiments were performed to compare the structure and transport function of three lung epithelial cells (Calu-3, normal human bronchial primary cells (NHBE), and NL-20). The cells were cultured on the nucleopore membranes in the air-liquid interface (ALI) culture conditions, with cell culture medium in the basolateral side only, starting from day 1. In transport assays, paracellular transport across all three types of cells appeared to be markedly different with the NHBE or Calu-3 cells, showing low paracellular permeability and high TEER values, while the NL-20 cells showed high paracellular permeability and low TEER. Quantitative image analysis of the confocal microscope sections further confirmed that the Calu-3 cells formed intact cell monolayers in contrast to the NHBE and NL-20 cells with multilayers. Among three lung epithelial cell types, the Calu-3 cell cultures under the ALI condition showed optimal cytometric features for mimicking the biophysical characteristics of in vivo airway epithelium. Therefore, the Calu-3 cell monolayers could be used as functional cell barriers for the lung-targeted drug transport studies.

  17. Fluorescent particles in the antibody solution result in false TF- and CD14-positive microparticles in flow cytometric analysis.

    Science.gov (United States)

    Aass, Hans Christian D; Øvstebø, Reidun; Trøseid, Anne-Marie S; Kierulf, Peter; Berg, Jens Petter; Henriksson, Carola Elisabeth

    2011-12-01

    Tissue factor (TF)-positive microparticles (MPs) are highly procoagulant, and linked to thrombosis in sepsis and cancer. MP-associated TF may be assayed by immunological or functional methods. Several reports have demonstrated discrepancies between TF-protein and TF-activity, which have been explained by antibody binding to "encrypted" or degraded forms of inactive TF-protein. Our goal was to evaluate the possible interference of fluorescent antibody aggregates in solutions containing antibodies against TF and CD14 in flow cytometric analysis. Using monocyte-derived microparticles (MPs) released from human monocytes, incubated with or without lipopolysaccharides (LPS) in vitro, we measured MP-associated TF-protein (flow cytometry) and TF-activity (clot formation assay). MPs released from monocytes exposed to LPS (1 ng mL(-1) ) had ∼14 times higher TF-activity than MPs originated from monocytes exposed to only culture medium. However, using untreated anti-TF antibodies (American Diagnostica and BD) in the flow cytometric analysis, MPs released from unstimulated monocytes had a similar number of TF-positive events as MPs secernated from LPS-stimulated monocytes [∼45,000 events mL(-1) (American Diagnostica); ∼15,000 events mL(-1) (BD)]. These TF-positive events did not exert any TF-activity, and centrifugation (17,000g, 30 min, 4°C) of the antibody solutions prior to use effectively removed the interfering fluorescent events. Removal of fluorescent interference, probably in the form of fluorescent antibody aggregates, from the antibody solutions by centrifugation is essential to prevent the occurrence of false positive flow cytometric events. The events can be mistaken as MP-associated TF-protein, and interpreted as a discrepancy between TF-protein and TF-activity. Copyright © 2011 International Society for Advancement of Cytometry.

  18. Flow cytometric assessment of microbial abundance in the near-field area of seawater reverse osmosis concentrate discharge

    KAUST Repository

    Van Der Merwe, Riaan

    2014-06-01

    The discharge of concentrate and other process waters from seawater reverse osmosis (SWRO) plant operations into the marine environment may adversely affect water quality in the near-field area surrounding the outfall. The main concerns are the increase in salt concentration in receiving waters, which results in a density increase and potential water stratification near the outfall, and possible increases in turbidity, e.g., due to the discharge of filter backwash waters. Changes in ambient water quality may affect microbial abundance in the area, for example by hindering the photosynthesis process or disrupting biogenesis. It is widely accepted that marine biodiversity is lower in more extreme conditions, such as high salinity environments. As aquatic microbial communities respond very rapidly to changes in their environment, they can be used as indicators for monitoring ambient water quality. The objective of this study was to assess possible changes in microbial abundance as a result of concentrate discharge into the near-field area (<. 25. m) surrounding the outfall of the King Abdullah University of Science and Technology (KAUST) SWRO plant. Flow cytometric (FCM) analysis was conducted in order to rapidly determine microbial abundance on a single-cell level in 107 samples, taken by diving, from the discharge area, the intake area and two control sites. FCM analysis combined the measurement of distinct scatter of cells and particles, autofluorescence of cyanobacteria and algae, and fluorescence after staining of nucleic acids with SYBR® Green for a total bacterial count. The results indicate that changes in microbial abundance in the near-field area of the KAUST SWRO outfall are minor and appear to be the result of a dilution effect rather than a direct impact of the concentrate discharge. © 2014 Elsevier B.V.

  19. Effect of 17 beta-oestradiol on growth curves and flow cytometric DNA distribution of two human breast carcinomas grown in nude mice

    DEFF Research Database (Denmark)

    Brünner, N; Spang-Thomsen, M; Vindeløv, L

    1983-01-01

    The effect of 17 beta-oestradiol on a "receptor positive" and on a "receptor negative" human breast carcinoma grown in nude mice was studied. Experimental growth data were used to determine the effect on tumour growth. Flow cytometric DNA analysis (FCM) performed on tumour tissue obtained...... by sequential fine-needle aspirations was used to estimate the effect on the cell cycle. In the receptor-positive breast carcinoma, oestradiol induced complete tumour regression and characteristic cell cycle changes. In the receptor-negative breast carcinoma, no changes in tumour growth and cell cycle...... prior to any reduction in the tumour size, the results suggest that FCM may prove a valuable method in the early detection of tumour response to hormone treatment in human breast cancer....

  20. Micronuclei frequency in circulating erythrocytes from rainbow trout (Oncorhynchus mykiss) subjected to radiation, an image analysis and flow cytometric study

    International Nuclear Information System (INIS)

    Schultz, N.; Norrgren, L.; Grawe, J.; Johannisson, A.; Medhage, O.

    1993-01-01

    Rainbow trout (oncorhynchus mykiss) were exposed to a single X-ray dose of 4 Gy. The frequency of micronuclei in the peripheral erythrocytes was investigated at regular intervals up to 58 days after the exposure. A flow cytometric method and a semi-automatic image analysis method were used to estimate the micronuclei frequency. The results show that both methods can detect an increased frequency of micronuclei in peripheral erythrocytes from exposed fish. However, the semi-automatic image analysis method was the most stable and sensitive. (Author)

  1. Fluorescence in situ hybridization and sequential catalysed reporter deposition (2C-FISH for the flow cytometric sorting of freshwater ultramicrobacteria

    Directory of Open Access Journals (Sweden)

    Stefan M Neuenschwander

    2015-03-01

    Full Text Available Flow cytometric sorting is a powerful tool to physically separate cells within mixed microbial communities. If combined with phylogenetic staining (fluorescence in situ hybridization, FISH it allows to specifically sort defined genotypic microbial populations from complex natural samples. However, the targeted enrichment of freshwater ultramicrobacteria, such as members of the LD12 clade of Alphaproteobacteria (SAR11-IIIb, is still challenging. Current FISH protocols, even in combination with signal amplification by catalysed reporter deposition (CARD, are not sufficiently sensitive for the distinction of these bacteria from background noise by flow cytometry, presumably due to their low ribosome content and small cell sizes. We, therefore, modified a CARD based flow sorting protocol with the aim of increasing its sensitivity to a level sufficient for ultramicrobacteria. This was achieved by a second signal amplification step mediated by horseradish peroxidase labelled antibodies targeted to the fluorophores that were previously deposited by CARD-FISH staining. The protocol was tested on samples from an oligo-mesotrophic lake. Ultramicrobacteria affiliated with LD12 Alphaproteobacteria could be successfully sorted to high purity by flow cytometry. The ratios of median fluorescence signal to background ranged around 20, and hybridization rates determined by flow cytometry were comparable to those obtained by fluorescence microscopy. Potential downstream applications of our modified cell staining approach range from the analysis of microdiversity within 16S rRNA-defined populations to that of functional properties, such as the taxon-specific incorporation rates of organic substrates.

  2. Rapid Detection and Enumeration of Giardia lamblia Cysts in Water Samples by Immunomagnetic Separation and Flow Cytometric Analysis ▿ †

    Science.gov (United States)

    Keserue, Hans-Anton; Füchslin, Hans Peter; Egli, Thomas

    2011-01-01

    Giardia lamblia is an important waterborne pathogen and is among the most common intestinal parasites of humans worldwide. Its fecal-oral transmission leads to the presence of cysts of this pathogen in the environment, and so far, quantitative rapid screening methods are not available for various matrices, such as surface waters, wastewater, or food. Thus, it is necessary to establish methods that enable reliable rapid detection of a single cyst in 10 to 100 liters of drinking water. Conventional detection relies on cyst concentration, isolation, and confirmation by immunofluorescence microscopy (IFM), resulting in low recoveries and high detection limits. Many different immunomagnetic separation (IMS) procedures have been developed for separation and cyst purification, so far with variable but high losses of cysts. A method was developed that requires less than 100 min and consists of filtration, resuspension, IMS, and flow cytometric (FCM) detection. MACS MicroBeads were used for IMS, and a reliable flow cytometric detection approach was established employing 3 different parameters for discrimination from background signals, i.e., green and red fluorescence (resulting from the distinct pattern emitted by the fluorescein dye) and sideward scatter for size discrimination. With spiked samples, recoveries exceeding 90% were obtained, and false-positive results were never encountered for negative samples. Additionally, the method was applicable to naturally occurring cysts in wastewater and has the potential to be automated. PMID:21685159

  3. Microbial Eco-Physiology of the human intestinal tract: a flow cytometric approach

    NARCIS (Netherlands)

    Amor, Ben K.

    2004-01-01

    This thesis describes a multifaceted approach to further enhance our view of the complex human intestinal microbial ecosystem. This approach combines me advantages of flow cyrometry (FCM), a single cell and high-throughput technology, and molecular techniques that have proven themselves to be

  4. Flow cytometric measurement of RNA synthesis using bromouridine labelling and bromodeoxyuridine antibodies

    DEFF Research Database (Denmark)

    Jensen, P O; Larsen, J; Christiansen, J

    1993-01-01

    Nuclear RNA synthesis can be analysed by flow cytometry of cells labelled with 5-bromouridine (BrUrd) and stained with anti-bromodeoxyuridine (BrdUrd) antibody and FITC-conjugated secondary antibody. A panel of 5 different commercially available anti-BrdUrd antibodies was tested on cells of a HL-60...... human leukemia cell line, stained as a methanol-fixed nuclear suspension. The BrUrd-induced fluorescence signals were highest with the antibody ABDM (Partec), moderate but reproducible with B-44 (Becton Dickinson), variable or low with BR-3 and IU-4 (Caltag), and not detectable with Bu20a (DAKO...... the variation of RNA synthesis during the cell cycle. The BrUrd incorporation was high in the S and G2 phase, variable in G1, and negligible in mitosis. Similar results were obtained using other cell types....

  5. Flow cytometric analysis of X-ray sensitivity in ataxia telangiectasia

    International Nuclear Information System (INIS)

    Rudolph, N.S.; Latt, S.A; Harvard Medical School, Boston

    1989-01-01

    Flow cytrometric analysis of 5-bromodeoxyuridine (BrdU) incorporation during DNA synthesis was used to characterize the effects of X-rays on cell-cycle kinetics in the DNA-repair deficiency disease ataxia telangiectasia (AT). Cultured fibroblasts from homozygotes (at/at), heterozygotes (at/+) and normal controls (+/+) were either: (1) irradiated, cultured, then pulsed with BrdU and harvested, or (2) pulsed with BrdU, irradiated, cultured and then harvested. Cells were then fixed and stained with both a fluoresceinated monoclonal antibody against BrdU to identify S-phase cells and with propidium diiodide to measure total DNA content. Irradiation of +/+ and at/+ cells induced a similar, transient G 2 /M arrest detectable within 8 h, which subsequently delayed by 6-8 h the passage of cells into G 1 and depleted early S phase. In contrast, at/at cells failed to arrest in G 2 /M phase and entered the next cell cycle withou pausing to repair radiation-induced damage. X-Rays also blocked entry of +/+ G 1 cells into S phase, subsequently reducing the total S-phase population. This effect was not observed in at/at cells. These cell-cycle responses to radiation may be of diagnostic use and ultimately may help explain the basic defect in AT. (author). 38 refs.; 7 figs.; 2 tabs

  6. Effect of acidic pH on flow cytometric detection of bacteria stained with SYBR Green I and their distinction from background

    International Nuclear Information System (INIS)

    Baldock, Daniel; Nocker, Andreas; Nebe-von-Caron, Gerhard; Bongaerts, Roy

    2013-01-01

    Unspecific background caused by biotic or abiotic particles, cellular debris, or autofluorescence is a well-known interfering parameter when applying flow cytometry to the detection of microorganisms in combination with fluorescent dyes. We present here an attempt to suppress the background signal intensity and thus to improve the detection of microorganisms using the nucleic acid stain SYBR ® Green I. It has been observed that the fluorescent signals from SYBR Green I are greatly reduced at acidic pH. When lowering the pH of pre-stained samples directly prior to flow cytometric analysis, we hypothesized that the signals from particles and cells with membrane damage might therefore be reduced. Signals from intact cells, temporarily maintaining a neutral cytosolic pH, should not be affected. We show here that this principle holds true for lowering background interference, whereas the signals of membrane-compromised dead cells are only affected weakly. Signals from intact live cells at low pH were mostly comparable to signals without acidification. Although this study was solely performed with SYBR ® Green I, the principle of low pH flow cytometry (low pH-FCM) might hold promise when analyzing complex matrices with an abundance of non-cellular matter, especially when expanded to non-DNA binding dyes with a stronger pH dependence of fluorescence than SYBR Green I and a higher pK a value. (paper)

  7. APPLICATION OF SIX-COLOR FLOW CYTOMETRIC ANALYSIS FOR IMMUNE PROFILE MONITORING

    Directory of Open Access Journals (Sweden)

    I. V. Kudryavtsev

    2015-01-01

    Full Text Available The article deals with applications of six-color flow analysis for studying the immune state parameters by means of flow cytometry. Whole blood from healthy donors was stained with combination of monoclonal antibodies, i.e., HLA-DR-FITC, CD16+56-PE, CD4-ECD, CD19-ECD, CD8-PC5.5, CD3-PC7, CD45-APC (Beckman Coulter, USA using a “no-wash” technology. To adjust the photomultiplier (PMT voltage, we used the tubes with each of the tested monoclonal antibodies, PMT voltage was considered optimal when the negative population was located in the middle of the first decade at the logarithmic scale. The compensatory adjustment was performed in automatic mode, using Navios software (Beckman Coulter, USA. We discuss an optimal gating strategy in order to assess the populations of interest: total T cells (CD3+CD19-, T helper cells (CD3+CD4+, cytotoxic T lymphocytes (CD3+CD8+, B cells (CD3-CD19+, NK cells (CD3-CD16+CD56+, NKT cells (CD3+CD16+CD56+, activated T lymphocytes (CD3+HLA-DR+. 

  8. Flow cytometric analysis of lymphocytes and lymphocyte subpopulations in induced sputum from patients with asthma

    Directory of Open Access Journals (Sweden)

    Yutaro Shiota

    2000-01-01

    Full Text Available Study objectives were to compare the numbers of lymphocytes and lymphocyte subpopulations in induced sputum from asthmatic patients and from healthy subjects, and to determine the effect of inhaled anti-asthmatic steroid therapy on these cell numbers. Hypertonic saline inhalation was used to non-invasively induce sputum samples in 34 patients with bronchial asthma and 21 healthy subjects. The sputum samples were reduced with dithioerythritol and absolute numbers of lymphocytes and lymphocyte subpopulations were assessed by direct immunofluorescence and flow cytometry. To assess the effect of beclomethasone dipropionate (BDP on induced sputum, numbers of lymphocytes and lymphocyte subpopulations in sputum also were evaluated after 4 weeks of BDP inhalation treatment in seven asthmatic patients. An adequate sample was obtained in 85.3% of patients with asthma and in 79.2% of the healthy subjects. Induced sputum from patients with asthma had increased numbers of lymphocytes (P = 0.009; CD4+ cells (P = 0.044; CD4+ cells-bearing interleukin-2 receptor (CD25; P = 0.016; and CD4+ cells bearing human histocompatibility leukocyte antigen (HLA-DR (P = 0.033. CD8+ cells were not increased in asthmatic patients. In patients treated with inhaled steroids, numbers of lymphocytes, CD4+ cells, CD25-bearing CD4+ cells and HLA-DR-bearing CD4+ cells in sputum decreased from pretreatment numbers (P = 0.016, 0.002, 0.003 and 0.002, respectively. Analysis of lymphocytes in induced sputum by flow cytometry is useful in assessing bronchial inflammation, and activated CD4+ lymphocytes may play a key role in the pathogenesis of airway inflammation in bronchial asthma.

  9. Flow cytometric determination of osmotic behaviour of animal erythrocytes toward their engineering for drug delivery

    Directory of Open Access Journals (Sweden)

    Kostić Ivana T.

    2015-01-01

    Full Text Available Despite the fact that the methods based on the osmotic properties of the cells are the most widely used for loading of drugs in human and animal erythrocytes, data related to the osmotic properties of erythrocytes derived from animal blood are scarce. This work was performed with an aim to investigate the possibility of use the flow cytometry as a tool for determination the osmotic behaviour of porcine and bovine erythrocytes, and thus facilitate the engineering of erythrocytes from animal blood to be drug carriers. The method of flow cytometry successfully provided the information about bovine and porcine erythrocyte osmotic fragility, and made the initial steps in assessment of erythrocyte shape in a large number of erythrocytes. Although this method is not able to confirm the swelling of pig erythrocytes, it indicated to the differences in pig erythrocytes that had basic hematological parameters inside and outside the reference values. In order to apply/use the porcine and bovine erythrocytes as drug carriers, the method of flow cytometry, confirming the presence of osmotically different fractions of red blood cells, indicated that various amounts of the encapsulated drug in porcine and bovine erythrocytes can be expected.

  10. Flow cytometric investigation of immune-response-related surface molecules on human colorectal cancers

    DEFF Research Database (Denmark)

    Diederichsen, Axel Cosmus Pyndt; Stenholm, A C; Kronborg, O

    1998-01-01

    different colorectal cancers were monitored by multiparameter flow cytometry. Gating on EP4+ cells, the expression of the surface molecules HLA class I, HLA class II, CD80 (B7-1), CD54 (ICAM-I) and CD58 (LFA-3) was evaluated. In 60 of 70 tumours, all tumour cells expressed HLA class I, in 10 tumours 15......Our purpose was to clarify whether human colorectal cancer cells are equipped to present tumour-associated-antigens to the immune system, and whether this ability correlates with lymphoid infiltration, the Dukes' stage and Jass classification. Enzymatically dissociated tumour cells from 70......-96% of the tumour cells expressed HLA class I. In 1 tumour, all tumour cells expressed HLA class II, in 67 tumours some expressed HLA class II, in 2 tumours none expressed HLA class II. Expression of CD58 was heterogeneous, and there was no or only sparse expression of CD80 and CD54. Expression of the HLA class I...

  11. Lymphocyte subset enumeration in HIV seronegative and HIV-1 seropositive adults in Dar es Salaam, Tanzania: determination of reference values in males and females and comparison of two flow cytometric methods.

    Science.gov (United States)

    Urassa, W K; Mbena, E M; Swai, A B; Gaines, H; Mhalu, F S; Biberfeld, G

    2003-06-01

    The level of CD4(+) T-lymphocytes represents a useful marker with which to monitor the progression of HIV infection. Sex and geographical differences in the reference values of lymphocyte subsets have been reported. We have compared two flow cytometric methods (MultiSET and SimulSET) for the quantification of lymphocyte subsets using whole blood from 92 HIV seropositive and 241 seronegative adults, and determined the reference values of lymphocyte subsets in HIV seronegative Tanzanian subjects. In seronegative Tanzanian subjects, the percentages of CD3(+) and CD4(+) T-lymphocytes and the CD4(+):CD8(+) T-lymphocyte ratios were lower while the percentage of natural killer cells was higher compared to the levels of the corresponding parameters reported for Europeans. Seronegative Tanzanian females had significantly higher levels of CD3(+) and CD4(+) T-lymphocytes and CD4(+):CD8(+) T-lymphocyte ratios compared to seronegative males. The correlation coefficients of CD3(+), CD4(+) and CD8(+) T lymphocyte counts and percentages obtained by the two flow cytometric methods were high. The median values of the number of CD4(+) T-lymphocytes obtained by the two methods were not significantly different. In conclusion, determination of the reference values of lymphocyte subsets in HIV seronegative Tanzanian adults showed significant sex differences and differences in percentage values compared to those reported in certain other geographical areas. There was acceptable agreement in the levels of CD4(+) T-lymphocyte values obtained by the two flow cytometric methods.

  12. Japanese Society for Laboratory Hematology flow cytometric reference method of determining the differential leukocyte count: external quality assurance using fresh blood samples.

    Science.gov (United States)

    Kawai, Y; Nagai, Y; Ogawa, E; Kondo, H

    2017-04-01

    To provide target values for the manufacturers' survey of the Japanese Society for Laboratory Hematology (JSLH), accurate standard data from healthy volunteers were needed for the five-part differential leukocyte count. To obtain such data, JSLH required an antibody panel that achieved high specificity (particularly for mononuclear cells) using simple gating procedures. We developed a flow cytometric method for determining the differential leukocyte count (JSLH-Diff) and validated it by comparison with the flow cytometric differential leukocyte count of the International Council for Standardization in Haematology (ICSH-Diff) and the manual differential count obtained by microscopy (Manual-Diff). First, the reference laboratory performed an imprecision study of JSLH-Diff and ICSH-Diff, as well as performing comparison among JSLH-Diff, Manual-Diff, and ICSH-Diff. Then two reference laboratories and seven participating laboratories performed imprecision and accuracy studies of JSLH-Diff, Manual-Diff, and ICSH-Diff. Simultaneously, six manufacturers' laboratories provided their own representative values by using automated hematology analyzers. The precision of both JSLH-Diff and ICSH-Diff methods was adequate. Comparison by the reference laboratory showed that all correlation coefficients, slopes and intercepts obtained by the JSLH-Diff, ICSH-Diff, and Manual-Diff methods conformed to the criteria. When the imprecision and accuracy of JSLH-Diff were assessed at seven laboratories, the CV% for lymphocytes, neutrophils, monocytes, eosinophils, and basophils was 0.5~0.9%, 0.3~0.7%, 1.7~2.6%, 3.0~7.9%, and 3.8~10.4%, respectively. More than 99% of CD45 positive leukocytes were identified as normal leukocytes by JSLH-Diff. When JSLH-Diff method were validated by comparison with Manual-Diff and ICSH-Diff, JSLH-Diff showed good performance as a reference method. © 2016 John Wiley & Sons Ltd.

  13. Flow-cytometric analysis of changes in lymphocyte subsets in the blood of cancer patients during radiation therapy

    International Nuclear Information System (INIS)

    Ogawa, Yasuhiro; Maeda, Tomoho; Ogawa, Yukiko

    1983-01-01

    In this study, we report a clinical application of a rapid flow-cytometric immunofluorescence method for studying lymphocyte subsets in whole blood by using monoclonal antibodies OKT3, OKT4, OKT8, OKIa1, OKT6, OKT10, OKT9, OKT11 and OKM1. Changes in the relative percentages and absolute counts of various lymphocyte subsets during radiotherapy of cancer patients were evaluated by this method. In patients with good response, the elevation of OKT 4 + -lymphocyte level and/or the depression of OKT8 + -lymphocyte level was observed. In contrast, the depression of OKT4 + -lymphocyte level and/or the elevation of OKT8 + -lymphocyte level was observed on patients with poor response. Our data indicate that these monoclonal antibodies can be regarded as invaluable tools for evaluation of immune status of cancer patients during radiotherapy. (author)

  14. Effect of 17 beta-oestradiol on growth curves and flow cytometric DNA distribution of two human breast carcinomas grown in nude mice

    DEFF Research Database (Denmark)

    Brünner, N; Spang-Thomsen, M; Vindeløv, L

    1983-01-01

    The effect of 17 beta-oestradiol on a "receptor positive" and on a "receptor negative" human breast carcinoma grown in nude mice was studied. Experimental growth data were used to determine the effect on tumour growth. Flow cytometric DNA analysis (FCM) performed on tumour tissue obtained...

  15. A heparin-based method for flow cytometric analysis of microparticles directly from platelet-poor plasma in calcium containing buffer

    DEFF Research Database (Denmark)

    Iversen, Line V; Ostergaard, Ole; Nielsen, Christoffer

    2013-01-01

    V negative MPs to clinical parameters in systemic diseases, which emphasize the importance of including characterization of AnxV-binding. An obstacle in flow cytometric analysis of AnxV-binding to MPs is that plasma may clot when adding the Ca(2+)-containing buffers. We here devise a simple method...

  16. Flow Cytometric Analysis of Leishmania Reactive CD4+/CD8+ Lymphocyte Proliferation in Cutaneous Leishmaniasis

    Directory of Open Access Journals (Sweden)

    H Keshavarz

    2008-12-01

    Full Text Available Background: Determination of the division history of T cells in vitro is helpful in the study of effector mechanisms against infections. Technique described here uses the intracellular fluorescent label carboxyfluorescein diacetate succinimidyl ester (CFSE to monitor the proliferation. Methods: In a cross sectional study, blood samples were collected from 7 volunteers with history of cutaneous leishmania­sis (CL and one healthy control from endemic areas in Isfahan province who referred to the Center for Research and Training in Skin Diseases and Leprosy (CRTSDL, then CD4+/CD8+ lymphocytes and CD14+ monocytes were isolated from peri­pheral blood mononuclear cells (PBMC using mAbs and magnetic nanoparticles. CFSE labeled CD4+ or CD8+ lympho­cytes cultured with autologous monocytes in the presence of PHA, SLA, live Leishmania major or as control with­out sti­mulation. Cells were harvested after 7 days and were analyzed using flow cytometry. Results: Five consecutive divisions were monitored separately. Stimulation of CD4+ or CD8+ lymphocytes from CL sub­jects with SLA showed a significant difference in proliferation comparing with unstimulated cells (P< 0.05. The signifi­cant difference in the percentages of CD4+ cells stimulated with SLA was revealed at different divisions for each subject. In CD8+ lymphocyte, significant stronger stimulation of SLA was evident later in the proliferation process. The mean number of divisions in both CD4+/CD8+ lymphocytes stimulated with SLA was significantly greater than when stimulated with live L. major (P=0.007 / P=0.012, respectively Conclusion: The percentage of divided cells might be calculated separately in each division. The cells remained active following CFSE staining and there is possibility of functional analysis simultaneously.

  17. Flow cytometric analysis of p21 protein expression on irradiated human lymphocytes; Analise por citometria de fluxo da expressao da proteina p21 em linfocitos humanos irradiados

    Energy Technology Data Exchange (ETDEWEB)

    Santos, N.F.G.; Amaral, A., E-mail: neyliane@gmail.com [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Departamento de Energia Nuclear. Laboratorio de Modelagem e Biodosimetria Aplicada; Freitas-Silva, R. [Universidade Federal de Pernambuco (UFPE), Garanhuns, PE (Brazil). Departamento de Ciencias Naturais e Exatas; Pereira, V.R.A. [Fundacao Oswaldo Cruz (FIOCRUZ), Recife, PE (Brazil). Centro de Pesquisas Aggeu Magalhaes. Departamento de Imunologia. Lab. de Imunoparasitologia; Tasat, D.R. [Universidad Nacional de General San Martin, Buenos Aires (Argentina). Escuela de Ciencia y Tecnologia. Laboratorio de Biologia Celular del Pulmon

    2013-08-15

    Cell cycle blockage in G1 is a mechanism p21 protein-regulated and coupled to DNA damage response to permit genetic content analysis, damage repair and cell death. Analysis of proteins that participates of this response has progressed with new analytic tools, and data contributes to comprehension of radioinduced molecular events as well as to new approaches on practices that employ ionizing radiation. On this perspective, the aim of this research was to evaluate, by flow cytometry, p21 expression on irradiated human lymphocytes, maintained under different experimental conditions. Peripheral blood samples from 10 healthy subjects were irradiated with doses of 0 (non-irradiated), 1, 2 and 4 Gy. Lymphocytes were processed to analysis on ex vivo (no cultured) condition and after 24; 48 and 72 hours culture, with and without phytohemagglutinin stimulation. p21 protein expression levels were measured by flow cytometry, as percentage values. Results indicate that flow cytometric assay allows detection of changes on p21 expression, since it was detected significant increase on phytohemagglutinin-stimulated samples, for all times, against basal expression (ex vivo). However, it was not observed significant alterations on p21 protein radioinduced levels, for all doses, times and culture conditions analyzed. These results not indicate so p21 protein as bioindicator of ionizing radiation exposure. Nevertheless, data confirmation may to require analysis of a more numerous population. (author)

  18. Flow cytometric evaluation of sperm parameters in relation to fertility potential.

    Science.gov (United States)

    Gillan, Lindsay; Evans, Gareth; Maxwell, W M C

    2005-01-15

    Most laboratory methods used to evaluate semen quality have not correlated highly with fertilizing capacity. The discovery of a variety of fluorochromes and compounds conjugated to fluorescent probes has enabled a more widespread analysis of sperm attributes, and in conjunction with the flow cytometer, permit the evaluation of a large number of spermatozoa. A number of characteristics of sperm integrity, viability and function can be assessed by flow cytometry. The DNA status of spermatozoa has been determined using the metachromatic properties of acridine orange (AO). AO staining, when used in the sperm chromatin structure assay (SCSA), correlates with fertility in a number of species. DNA fragmentation can also be assessed using the terminal deoxynucleotidyl transferase-mediated dUTP nick-end labeling (TUNEL) assay, which identifies DNA strand breaks by labeling free 3'-OH termini with modified nucleotides. The status of the sperm acrosome can be determined using fluorescently labeled lectins and LysoTracker Green DND-26, a fluorescent acidotropic probe. Capacitation status has been observed through calcium-mediated changes using chlortetracycline (CTC) or by changes in membrane fluidity monitored by the binding of the fluorescent amphiphilic probe, Merocyanine 540. Fluorescently labeled annexin-V, C6NBD and Ro-09-0198 can also be used to detect changes in membrane phospholipid distribution. Cell viability can be determined using the propensity of propidium iodide (PI), ethidium homodimer-1 (EthD-1) or Yo-Pro-1 to permeate damaged membranes. These are generally more adaptable to clinical flow cytometry than the bisbenzimide membrane impermeable stain, Hoechst 33258, which excites in the ultraviolet range and requires UV laser equipment. Mitochondrial function can be determined using rhodamine 123 (R123) and MitoTracker Green FM (MITO) and 5,5',6,6'-tetrachloro-1,1',3,3'-tetraethylbenzimidazolyl-carbocyanine iodide (JC-1). Flow cytometry is a tool that may be used

  19. Dysregulated angiogenesis in B-chronic lymphocytic leukemia: Morphologic, immunohistochemical, and flow cytometric evidence

    Directory of Open Access Journals (Sweden)

    Crawford Susan E

    2008-04-01

    Full Text Available Abstract Background The extent of enhanced bone marrow angiogenesis in chronic lymphocytic leukemia (CLL and relationship to proangiogenic factors and prognostic indicators is largely unexplored. Methods To further investigate the role of angiogenesis in CLL by evaluating the topography and extent of angiogenesis in a group of CLL bone marrow biopsies, to study the expression of pro and antiangiogenic vascular factors in CLL cells to more precisely document the cell types producing these factors, and to evaluate the role, if any, of localized hypoxia in upregulation of angiogenesis in CLL We used immunohistochemistry (IHC (n = 21 pts with antibodies to CD3 and CD20, proangiogenic (VEGF, HIF-1a and antiangiogenic (TSP-1 factors, and VEGF receptors -1 and -2 to examine pattern/extent of CLL marrow involvement, microvessel density (MVD, and angiogenic characteristics; flow cytometry (FC was performed on 21 additional cases for VEGF and TSP-1. Results CLL patients had higher MVD (23.8 vs 14.6, p~0.0002 compared to controls (n = 10. MVD was highest at the periphery of focal infiltrates, was not enhanced in proliferation centers, and was increased irrespective of the presence or absence of cytogenetic/immunophenotypic markers of aggressivity. By IHC, CLL cells were VEGF(+, HIF-1a (+, TSP-1(-, VEGFR-1(+, and VEGFR-2(+. By FC, CLL cells were 1.4–2.0-fold brighter for VEGF than T cells and were TSP-1(-. Conclusion CLL demonstrates enhanced angiogenesis, with increased MVD, upregulated VEGF and downregulated TSP-1. Upregulation of HIF-1a in all CLL cases suggests localized tissue hypoxia as an important stimulant of microvessel proliferation. The presence of VEGF receptors on CLL cells implies an autocrine effect for VEGF. Differences in MVD did not correlate with traditional genetic/immunophenotypic markers of aggressiveness.

  20. Clinical flow cytometric screening of SAP and XIAP expression accurately identifies patients with SH2D1A and XIAP/BIRC4 mutations.

    Science.gov (United States)

    Gifford, Carrie E; Weingartner, Elizabeth; Villanueva, Joyce; Johnson, Judith; Zhang, Kejian; Filipovich, Alexandra H; Bleesing, Jack J; Marsh, Rebecca A

    2014-07-01

    X-linked lymphoproliferative disease is caused by mutations in two genes, SH2D1A and XIAP/BIRC4. Flow cytometric methods have been developed to detect the gene products, SAP and XIAP. However, there is no literature describing the accuracy of flow cytometric screening performed in a clinical lab setting. We reviewed the clinical flow cytometric testing results for 656 SAP and 586 XIAP samples tested during a 3-year period. Genetic testing was clinically performed as directed by the managing physician in 137 SAP (21%) and 115 XIAP (20%) samples. We included these samples for analyses of flow cytometric test accuracy. SH2D1A mutations were detected in 15/137 samples. SAP expression was low in 13/15 (sensitivity 87%, CI 61-97%). Of the 122 samples with normal sequencing, SAP was normal in 109 (specificity 89%, CI 82-94%). The positive predictive values (PPVs) and the negative predictive values (NPVs) were 50% and 98%, respectively. XIAP/BIRC4 mutations were detected in 19/115 samples. XIAP expression was low in 18/19 (sensitivity 95%, CI 73-100%). Of the 96 samples with normal sequencing, 59 had normal XIAP expression (specificity 61%, CI 51-71%). The PPVs and NPVs were 33% and 98%, respectively. Receiver-operating characteristic analysis was able to improve the specificity to 75%. Clinical flow cytometric screening tests for SAP and XIAP deficiencies offer good sensitivity and specificity for detecting genetic mutations, and are characterized by high NPVs. We recommend these tests for patients suspected of having X-linked lymphoproliferative disease type 1 (XLP1) or XLP2. © 2014 Clinical Cytometry Society.

  1. Flow cytometric assay for analysis of cytotoxic effects of potential drugs on human peripheral blood leukocytes

    Science.gov (United States)

    Nieschke, Kathleen; Mittag, Anja; Golab, Karolina; Bocsi, Jozsef; Pierzchalski, Arkadiusz; Kamysz, Wojciech; Tarnok, Attila

    2014-03-01

    Toxicity test of new chemicals belongs to the first steps in the drug screening, using different cultured cell lines. However, primary human cells represent the human organism better than cultured tumor derived cell lines. We developed a very gentle toxicity assay for isolation and incubation of human peripheral blood leukocytes (PBL) and tested it using different bioactive oligopeptides (OP). Effects of different PBL isolation methods (red blood cell lysis; Histopaque isolation among others), different incubation tubes (e.g. FACS tubes), anticoagulants and blood sources on PBL viability were tested using propidium iodide-exclusion as viability measure (incubation time: 60 min, 36°C) and flow cytometry. Toxicity concentration and time-depended effects (10-60 min, 36 °C, 0-100 μg /ml of OP) on human PBL were analyzed. Erythrocyte lysis by hypotonic shock (dH2O) was the fastest PBL isolation method with highest viability (>85%) compared to NH4Cl-Lysis (49%). Density gradient centrifugation led to neutrophil granulocyte cell loss. Heparin anticoagulation resulted in higher viability than EDTA. Conical 1.5 mL and 2 mL micro-reaction tubes (both polypropylene (PP)) had the highest viability (99% and 97%) compared to other tubes, i.e. three types of 5.0 mL round-bottom tubes PP (opaque-60%), PP (blue-62%), Polystyrene (PS-64%). Viability of PBL did not differ between venous and capillary blood. A gentle reproducible preparation and analytical toxicity-assay for human PBL was developed and evaluated. Using our assay toxicity, time-course, dose-dependence and aggregate formation by OP could be clearly differentiated and quantified. This novel assay enables for rapid and cost effective multiparametric toxicological screening and pharmacological testing on primary human PBL and can be adapted to high-throughput-screening.°z

  2. Flow cytometric analysis of microparticle phenotype and their role in thrombin generation.

    Science.gov (United States)

    Macey, M G; Enniks, N; Bevan, S

    2011-01-01

    Microparticles may be generated from a number of cell types and are known to play a role in haemostasis by a variety of mechanisms. We investigated the role of platelet, red cell, and leucocyte-derived microparticles in the measurement of thrombin generation. Four parameters of thrombin generation (the endogenous thrombin potential (ETP), lag time, time to peak, peak height) and microparticle content was determined in 35 plasma samples from normal individuals pre and post filtration to remove microparticles. Immunofluorescent flow cytometry was used to identify and enumerate platelet, leucocyte, monocyte and red cell derived microparticles in plasma samples based on the expression of CD42b, CD45, CD15, and Glycophorin A respectively. Expression of phosphatidylserine and tissue factor by microparticles was determined by Annexin V and anti CD142 binding. The pre and post filtration results were compared. There was a significant decrease in ETP and Peak Height, and an increase in the time to peak post filtration (P microparticles was also observed. The change in CD42b+ microparticles correlated highly with the change in Annexin V+ microparticles (r = 0.68). Whilst the change in ETP correlated best with the change in CD15+ microparticles (r = 0.45) and the change in time to peak correlated with the change in Annexin V binding (r = 0.52) (P < 0.01). The presence of micropartcles in plasma significantly affects thrombin generation. Copyright © 2010 International Clinical Cytometry Society.

  3. Flow-cytometric study of vital cellular functions in Escherichia coli during solar disinfection (SODIS).

    Science.gov (United States)

    Berney, Michael; Weilenmann, Hans-Ulrich; Egli, Thomas

    2006-06-01

    The effectiveness of solar disinfection (SODIS), a low-cost household water treatment method for developing countries, was investigated with flow cytometry and viability stains for the enteric bacterium Escherichia coli. A better understanding of the process of injury or death of E. coli during SODIS could be gained by investigating six different cellular functions, namely: efflux pump activity (Syto 9 plus ethidium bromide), membrane potential [bis-(1,3-dibutylbarbituric acid)trimethine oxonol; DiBAC4(3)], membrane integrity (LIVE/DEAD BacLight), glucose uptake activity (2-[N-(7-nitrobenz-2-oxa-1,3-diazol-4-yl)amino]-2-deoxy-d-glucose; 2-NBDG), total ATP concentration (BacTiter-Glo) and culturability (pour-plate method). These variables were measured in E. coli K-12 MG1655 cells that were exposed to either sunlight or artificial UVA light. The inactivation pattern of cellular functions was very similar for both light sources. A UVA light dose (fluence) of 80 % of the cells was observed at a fluence of approximately 1500 kJ m(-2), and the cytoplasmic membrane of bacterial cells became permeable at a fluence of >2500 kJ m(-2). Culturable counts of stressed bacteria after anaerobic incubation on sodium pyruvate-supplemented tryptic soy agar closely correlated with the loss of membrane potential. The results strongly suggest that cells exposed to >1500 kJ m(-2) solar UVA (corresponding to 530 W m(-2) global sunlight intensity for 6 h) were no longer able to repair the damage and recover. Our study confirms the lethal effect of SODIS with cultivation-independent methods and gives a detailed picture of the 'agony' of E. coli when it is stressed with sunlight.

  4. Comparison of quantitative flow cytometric data provided by panels with lower and increased color number

    Science.gov (United States)

    Bocsi, József; Mittag, Anja; Pierzchalski, Arkadiusz; Baumgartner, Adolf; Dähnert, Ingo; Tárnok, Attila

    2012-03-01

    To date the flow cytometry (FCM) industry is booming with new generations of commercial clinical instruments. Long-term clinical studies have the dilemma that moving to new instruments being capable of more complex cell-analysis makes it difficult to compare new data with those obtained on older instruments with less complex analysis panels. Since 15 years we conduct follow-up studies on children with congenital heart diseases. In this period we moved from 2- to 3- and now to 10-color FCM immunophenotyping panels. Questions arise how to compare and transfer data from lower to higher level of complexity. Two comparable antibody panels for leukocyte immunophenotyping (12-tube 2-colors, and 9-tube 4-colors) were measured on a BD FACScalibur FCM (calibration: Spherotech beads) in 19 blood samples from children with congenital heart disease. This increase of colors was accompanied by moving antibodies that were in the 2-color panel either FITC or PE labeled to red dyes such as PerCP or APC. Algorithms were developed for bridging data for quantitative characterization of antigen expression (mean fluorescence intensity) and frequency of different cell subpopulations in combination with rainbow bead standard data. This approach worked for the most relevant antibodies (CD3, CD4, CD8 etc.) well, but rendered substantial uncertainty for activation markers (CD69 etc.). Our techniques are particularly well suited to the analysis in long-term studies and have the potential to compare older and recent results in a standardized way.

  5. Flow-cytometric assessment of cellular poly(ADP-ribosylation capacity in peripheral blood lymphocytes

    Directory of Open Access Journals (Sweden)

    Hyland Paul

    2006-07-01

    Full Text Available Abstract Background Poly(ADP-ribosylation is a posttranslational modification of nuclear proteins catalysed by poly(ADP-ribose polymerases (PARPs, using NAD+ as a substrate. Activation of PARP-1 is in immediate response to DNA damage generated by endogenous and exogenous damaging agents. It has been implicated in several crucial cellular processes including DNA repair and maintenance of genomic stability, which are both intimately linked with the ageing process. The measurement of cellular poly(ADP-ribosylation capacity, defined as the amount of poly(ADP-ribose produced under maximal stimulation, is therefore relevant for research on ageing, as well as for a variety of other scientific questions. Results This paper reports a new, robust protocol for the measurement of cellular poly(ADP-ribosylation capacity in PBMC or Jurkat T-cells using flow cytometry, based on a previously established immuno-dot-blot assay. In order to validate the new assay, we determined the dose-response curve of 3-aminobenzamide, a well-known competitive PARP inhibitor, and we derived an IC50 that is very close to the published value. When testing a set of PBMC samples taken from fifteen healthy young human donors, we could confirm the presence of a substantial interindividual variation, as previously observed using a radiometric assay. Conclusion The methodology described in this paper should be generally useful for the determination of cellular poly(ADP-ribosylation capacity in a wide variety of settings, especially for the comparison of large sets of samples, such as population studies. In contrast to previously published radiometric or immuno-dot-blot assays, the new FACS-based method allows (i selective analysis of mononuclear cells by gating and (ii detection of a possible heterogeneity in poly(ADP-ribosylation capacity between cells of the same type.

  6. Simple flow cytometric protocol of CD4+/CD8+ lymphocyte ratio assessment in bronchoalveolar lavage fluids from patients with interstitial lung diseases.

    Science.gov (United States)

    Szpechcinski, Adam; Kopinski, Piotr; Giedronowicz, Dorota; Rozy, Adriana; Jagus, Paulina; Szolkowska, Malgorzata; Chorostowska-Wynimko, Joanna

    2011-10-01

    To validate the fast and accurate flow cytometric (FCM) protocol using blood-standardized antibodies for alveolar lymphocyte subtyping with respect to standard immunocytochemistry (IC). FCM and IC were applied to immunophenotype T cell subsets in bronchoalveolar lavage (BAL) fluids from patients with interstitial lung diseases. Diagnostic BAL specimens from 50 patients with suspected sarcoidosis, idiopathic pulmonary fibrosis, and hypersensitivity pneumonitis were evaluated by both IC and FCM. In FCM, CD4+ and CD8+ T cells were identified by light scatter gating with CD3 selection using basic tricolor cytometer. Relative amounts of CD4+, CD8+ T cells, and CD4+/CD8+ ratios demonstrated by the FCM showed excellent, significant correlations with IC results. FCM values did not differ significantly from IC results. However, the sensitivity and specificity of conventional IC staining were not sufficient to assess CD4+/ CD8+ ratio in most idiopathic pulmonary fibrosis cases. Additionally, performing IC immunophenotyping in BAL samples with low lymphocyte content introduced a remarkable error into CD4+/CD8+ ratio assessment. FCM allowed reliable, precise, and fast T-cell subset measurement in all BAL samples, overcoming the IC disadvantages. Our validated FCM protocol provides diagnostically relevant CD4+/CD8+ ratio determination by simple light scatter gating strategy with CD3 selection.

  7. Evaluation of chromatin condensation in human spermatozoa: a flow cytometric assay using acridine orange staining.

    Science.gov (United States)

    Golan, R; Shochat, L; Weissenberg, R; Soffer, Y; Marcus, Z; Oschry, Y; Lewin, L M

    1997-01-01

    The quality of sperm chromatin is an important factor in fertilization and is especially critical where one spermatozoon is artificially selected for fertilizing an egg (as in intracytoplasmic sperm injection). In this study, flow cytometry after staining of human spermatozoa with Acridine Orange was used to study chromatin structure. A method is described for estimating the percentage of cells in a human sperm sample that have completed epididymal maturation in regard to chromatin condensation. Of the 121 samples of the semen that were examined, nine contained a higher percentage of hypocondensed spermatozoa and six samples contained elevated amounts of hypercondensed spermatozoa. In addition to aberrancies in chromatin condensation other defects showed up as satellite populations of spermatozoa with higher than normal ratios of red/green fluorescence after Acridine Orange staining. Such defects were found in 15 semen samples. The use of swim-up and Percoll gradient centrifugation methods was shown to improve the percentage of spermatozoa with normal chromatin structure in some samples with poor initial quality.

  8. Proposed criterion for distinguishing ABO mosaics from ABO chimeras using flow cytometric analysis.

    Science.gov (United States)

    Oda, Akira; Matsuyama, Nobuki; Hirashima, Mizuko; Ishii, Hiroyuki; Kimura, Keiko; Matsukura, Harumichi; Hirayama, Fumiya; Kawa, Keisei; Fukumori, Yasuo

    2015-01-01

    Differentiation of ABO mosaics from chimeras is performed using flow cytometry (FCM) analysis. Although mosaics and chimeras have been distinguished by presence or absence of clear resolution using FCM analysis, the lack of quantitative metrics and definitive criteria for this differentiation has made some cases difficult to differentiate. In this study, therefore, we attempted to establish a definitive and quantitative criterion for this differentiation. When FCM histogram gates for group "A" or "B" antigen-negative and -positive red blood cells (RBCs) were set such that group O RBCs were classified as 99 percent negative and group A or B RBCs as 99 percent positive, the percentages of RBCs in the middle region of six chimeras and 23 mosaics (12 A mosaics and 11 B mosaics) were 0.1-0.6 percent and 7.0-19.0 percent, respectively. This results suggested that ABO mosaics and chimeras can be unambiguously differentiated when the cutoff point of the intermediate region is set to 1 percent.

  9. An improved flow cytometric immunobead array to detect autoantibodies in plasma from patients with immune thrombocytopenic purpura.

    Science.gov (United States)

    Zhao, Yunxiao; Zhu, Mingqing; Jiang, Miao; Zuo, Bin; Wu, Qingyu; Ruan, Changgeng; He, Yang

    2015-01-01

    Autoantibodies against platelet glycoproteins (GPs) play an important role in immune thrombocytopenic purpura (ITP). This study was to develop an improved flow cytometric immunobead array (FCIA) assay to detect platelet autoantibodies in ITP patient plasma. Plasma samples were isolated from 71 ITP patients and 136 non-ITP controls and incubated with platelets from normal individuals. After washing, platelets were lysed and the platelet lysates were incubated with polystyrene microbeads coupled with monoclonal antibodies against human GPs IX (SZ1), Ib (SZ2), IIIa (SZ21), IIb (SZ22), and P-selectin (SZ51). Platelet GP-autoantibody complexes were detected by flow cytometry using a FITC-labeled secondary antibody. Autoantibodies against platelet GPIb, GPIIb, GPIIIa, GPIX and P-selectin were detected in plasma from ITP patients, as indicated by high mean fluorescent intensity values when microbeads with antibodies SZ1, SZ2, SZ21, SZ22, and SZ51 were used. In ROC analysis, values of the area under the curve were 0.74, 0.83, 0.80, 0.79 and 0.87, respectively. Compared with the previously reported assays, this new FCIA eliminated the need of isolating platelets from ITP patients without compromising assay sensitivity and accuracy in predicting ITP. This simplified FICA assay may be more suitable for ITP diagnosis in clinical laboratory settings. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Monitoring microbiological changes in drinking water systems using a fast and reproducible flow cytometric method

    KAUST Repository

    Prest, Emmanuelle I E C

    2013-12-01

    Flow cytometry (FCM) is a rapid, cultivation-independent tool to assess and evaluate bacteriological quality and biological stability of water. Here we demonstrate that a stringent, reproducible staining protocol combined with fixed FCM operational and gating settings is essential for reliable quantification of bacteria and detection of changes in aquatic bacterial communities. Triplicate measurements of diverse water samples with this protocol typically showed relative standard deviation values and 95% confidence interval values below 2.5% on all the main FCM parameters. We propose a straightforward and instrument-independent method for the characterization of water samples based on the combination of bacterial cell concentration and fluorescence distribution. Analysis of the fluorescence distribution (or so-called fluorescence fingerprint) was accomplished firstly through a direct comparison of the raw FCM data and subsequently simplified by quantifying the percentage of large and brightly fluorescent high nucleic acid (HNA) content bacteria in each sample. Our approach enables fast differentiation of dissimilar bacterial communities (less than 15min from sampling to final result), and allows accurate detection of even small changes in aquatic environments (detection above 3% change). Demonstrative studies on (a) indigenous bacterial growth in water, (b) contamination of drinking water with wastewater, (c) household drinking water stagnation and (d) mixing of two drinking water types, univocally showed that this FCM approach enables detection and quantification of relevant bacterial water quality changes with high sensitivity. This approach has the potential to be used as a new tool for application in the drinking water field, e.g. for rapid screening of the microbial water quality and stability during water treatment and distribution in networks and premise plumbing. © 2013 Elsevier Ltd.

  11. Flow cytometric analysis of platelet cyclooxygenase-1 and -2 and surface glycoproteins in patients with immune thrombocytopenia and healthy individuals.

    Science.gov (United States)

    Rubak, Peter; Kristensen, Steen D; Hvas, Anne-Mette

    2017-06-01

    Immature platelets may contain more platelet enzymes such as cyclooxygenase (COX)-1 and COX-2 than mature platelets. Patients with immune thrombocytopenia (ITP) have a higher fraction of immature platelets and can therefore be utilized as a biological model for investigating COX-1 and COX-2 platelet expression. The aims were to develop flow cytometric assays for platelet COX-1 and COX-2 and to investigate the COX-1 and COX-2 platelet expression, platelet turnover, and platelet glycoproteins in ITP patients (n = 10) compared with healthy individuals (n = 30). Platelet count and platelet turnover parameters (mean platelet volume (MPV), immature platelet fraction (IPF), and immature platelet count (IPC)) were measured by flow cytometry (Sysmex XE-5000). Platelet COX-1, COX-2, and the glycoproteins (GP)IIb, IX, Ib, Ia, and IIIa were all analyzed by flow cytometry (Navios) and expressed as median fluorescence intensity. COX analyses were performed in both whole blood and platelet rich plasma (PRP), whereas platelet glycoproteins were analyzed in whole blood only. ITP patients had significantly lower platelet count (55 × 10 9 /L) than healthy individuals (240 × 10 9 /L, p platelet count and IPC (both p-values Platelet COX-1 expression was higher in ITP patients than healthy individuals using whole blood (p COX-1 platelet turnover and COX-1 expression (all p-values platelet turnover and COX-1 and COX-2 expressions (all p-values platelet turnover in ITP patients (all p-values 0.14, rho = 0.11-0.28). In conclusion, ITP patients expressed higher COX-1 and platelet glycoprotein levels than healthy individuals. COX-1 and platelet glycoproteins demonstrated positive correlations with platelet turnover in ITP patients. In healthy individuals, COX-1 and COX-2 expression correlated positively with platelet turnover. PRP was more sensitive compared with whole blood as regards determination of COX. Therefore, PRP is the recommended matrix for investigating COX-1 and COX-2 in

  12. Proliferation and apoptosis in infection with infectious bursal disease virus: a flow cytometric study.

    Science.gov (United States)

    Ojeda, F; Skardova, I; Guarda, M I; Ulloa, J; Folch, H

    1997-01-01

    Programmed cell death, or apoptosis, is involved in the normal physiology of many immunocompetent organs, including lymphocytes of the bursa of Fabricius in chickens. Involvement of apoptosis has also been described in some viral diseases such as AIDS. The purpose of this work was to study the potential role of apoptosis in the pathogenesis of Gumboro disease in the bursa of Fabricius. Our results show that 1-3 days after infection of young chickens with infectious bursal disease virus, the number of apoptotic cells increases and cellularity and proliferation decrease. Because of the dynamic nature of bursal lymphocyte populations and the involvement of apoptosis in lymphocyte cell physiology, the increased level of cells undergoing apoptosis may be due to an impairment in the withdrawal of apoptotic cells. A concomitant increase in macrophages in infected bursae and a dramatic decrease in cellularity suggest that an increase in apoptosis may be an important cause of cell depletion.

  13. Single-laboratory validation of a multiplex flow cytometric immunoassay for the simultaneous detection of coccidiostats in eggs and feed.

    Science.gov (United States)

    Bienenmann-Ploum, Monique E; Vincent, Ursula; Campbell, Katrina; Huet, Anne-Catherine; Haasnoot, Willem; Delahaut, Philippe; Stolker, Linda A A M; Elliott, Christopher T; Nielen, Michel W F

    2013-11-01

    Coccidiostats are authorized in the European Union (EU) to be used as poultry feed additives. Maximum (residue) levels (M(R)Ls) have been set within the EU for consumer and animal protection against unintended carry-over, and monitoring is compulsory. This paper describes the single-laboratory validation of a previously developed multiplex flow cytometric immunoassay (FCIA) as screening method for coccidiostats in eggs and feed and provides and compares different approaches for the calculation of the cut-off levels which are not described in detail within Commission Decision 2002/657/EC. Comparable results were obtained between the statistical (reference) approach and the rapid approaches. With the most rapid approach, the cut-off levels for narasin/salinomycin, lasalocid, diclazuril, nicarbazin (DNC) and monensin in egg, calculated as percentages of inhibition (%B/B0), were 60, 32, 76, 80 and 84, respectively. In feed, the cut-off levels for narasin/salinomycin, lasalocid, nicarbazin (DNC) and monensin were 70, 64, 72 and 78, respectively, and could not be determined for diclazuril. For all analytes, except for diclazuril in feed, the rate of false positives (false non-compliant) in blank samples was lower than 1 %, and the rate of false negatives (false compliant) at the M(R)Ls was below 5 %. Additionally, very good correlations (r ranging from 0.994 to 0.9994) were observed between two different analysers, a sophisticated flow cytometer (FlexMAP 3D(®)) and a more cost-efficient and transportable planar imaging detector (MAGPIX(®)), hence demonstrating adequate transferability.

  14. [Standardization of the quantitative flow cytometric test with anti-D antibodies for fetomaternal hemorrhage in RhD negative women].

    Science.gov (United States)

    Spychalska, Justyna; Uhrynowska, Małgorzata; Pyl, Hanna; Klimczak-Jajor, Edyta; Kopeć, Izabella; Peciakowska, Małgorzata; Gutowska, Renata; Gawlak, Maciej; Słomska, Sylwia; Dąbkowska, Syiwia; Szczecina, Roman; Dębska, Marzena; Brojer, Ewa

    2015-07-01

    In order to determine the appropriate dose of anti-D immunoglobulin to be administered as a preventive measure against hemolytic disease of the fetus/newborn in the subsequent pregnancy it is necessary to assess the number of fetal red blood cells that infiltrate/penetrate into the maternal circulation as a result of fetomaternal hemorrhage (FMH). One of the quantitative methods of FMH analysis is based on flow cytometry (FACS) which makes use of monoclonal antibodies to RhD antigen (anti-D test). The aim of the study was to further develop the method, evaluate its sensitivity and reproducibility and to compare it with the test based on the detection of fetal hemoglobin (HbF). The FACS study involved 20 RhD negative pregnant women and 80 RhD negative women after delivery. The following monoclonal antibodies were used: BRAD 3 FITC (anti-RhD antigen), CD45 PerCP (anti leukocyte antigen CD45), and anti-HbF PE. The fluorescence intensity of cells incubated with BRAD 3 FITC was demonstrated to depend on the RhD antigen expression, though the anti-D test also detects the weak D variant. The CD45 PerCP antibodies increased the sensitivity of anti-D test since they eliminated the leukocytes which non-specifically bind anti-D from the analysis. The presence of anti-D antibodies in maternal plasma does not affect the quantitative assessment of the fetal RhD positive fetal cells with BRAD 3 FITC. In case of FMH, the results of the anti-D test were similar to those with anti-HbF antibodies. The flow cytometric test with anti-D and anti-CD45 is useful in the assessment of the fetomaternal hemorrhage in RhD negative women. The sensitivity of the test is estimated at 0.05%.

  15. Nuclear chromatin variations in human spermatozoa undergoing swim-up and cryopreservation evaluated by the flow cytometric sperm chromatin structure assay.

    Science.gov (United States)

    Spanò, M; Cordelli, E; Leter, G; Lombardo, F; Lenzi, A; Gandini, L

    1999-01-01

    The sperm chromatin structure assay (SCSA) is a flow cytometric (FCM) technique which exploits the metachromatic properties of Acridine Orange to monitor the susceptibility of sperm chromatin DNA to in-situ acid denaturation. SCSA was used to study the chromatin structure variations of human spermatozoa in semen, both before and after swim-up and after cryopreservation. Semen samples were provided by 19 healthy normozoospermic subjects attending pre-marriage checks. Each sample was divided into three aliquots: the first aliquot was evaluated without further treatment, the second underwent swim-up, and the third was stored according to standard cryopreservation techniques in liquid nitrogen at -196 degrees C. Samples were also analysed by light and fluorescence microscopy (after Acridine Orange staining to evaluate the number of green fluorescent sperm heads), and by computer-assisted semen analysis. The results showed that post-rise spermatozoa represent a subpopulation characterized by a general improvement of the morphological (reduction of the percentage of abnormal forms and heads, increase of the green head sperm percentage) and kinetic parameters. This subpopulation also exhibited improved chromatin structure properties, confirming that these cells have the best structural and functional characteristics, indicative of optimal fertilizing ability. On the other hand, overall sperm quality deteriorates after cryopreservation. When thawed spermatozoa underwent an additional swim-up round, a general improvement of nuclear maturity was seen in the post-rise spermatozoa.

  16. Quick cytogenetic screening of breeding bulls using flow cytometric sperm DNA histogram analysis.

    Science.gov (United States)

    Nagy, Szabolcs; Polgár, Péter J; Andersson, Magnus; Kovács, András

    2016-09-01

    The aim of the present study was to test the FXCycle PI/RNase kit for routine DNA analyses in order to detect breeding bulls and/or insemination doses carrying cytogenetic aberrations. In a series of experiments we first established basic DNA histogram parameters of cytogenetically healthy breeding bulls by measuring the intraspecific genome size variation of three animals, then we compared the histogram profiles of bulls carrying cytogenetic defects to the baseline values. With the exception of one case the test was able to identify bulls with cytogenetic defects. Therefore, we conclude that the assay could be incorporated into the laboratory routine where flow cytometry is applied for semen quality control.

  17. Flow cytometric analysis of lymphocytes in aplastic anemia among atomic bomb survivors

    International Nuclear Information System (INIS)

    Imamura, Nobutaka; Inada, Tominari; Asaoku, Hideki; Abe, Kazuhiro; Oguma, Nobuo; Kuramoto, Atsushi

    1986-01-01

    In 6 patients with aplastic anemia and 3 patients with pernicious anemia, lymphocyte subpopulations in the peripheral blood were measured, before and after steroid therapy, with a fluorescence-activated cell sorder using various monoclonal antibodies. The ratio of OKT4-positive lymphocytes (T4) to OKT8-positive lymphocytes (T8) in the peripheral blood was reduced in 2 patients (20 %). The T4/T8 ratio returned to normal during remission of anemia. Hematological improvement was seen after a large amount of steroid therapy in 3 patients. The number of Tac-positive cells tended to decrease and the T4/T8 ratio tended to return to normal with hematological improvement, although there was no correlation to hydrocortisone reaction. Some patients were supposed to have abnormal number of suppressor and inducer T cells. (Namekawa, K.)

  18. Flow cytometric analysis of RNA synthesis by detection of bromouridine incorporation

    DEFF Research Database (Denmark)

    Larsen, J K; Jensen, Peter Østrup; Larsen, J

    2001-01-01

    RNA synthesis has traditionally been investigated by a laborious and time-consuming radiographic method involving incorporation of tritiated uridine. Now a faster non-radioactive alternative has emerged, based on immunocytochemical detection. This method utilizes the brominated RNA precursor...... bromouridine, which is taken into a cell, phosphorylated, and incorporated into nascent RNA. The BrU-substituted RNA is detected by permeabilizing the cells and staining with certain anti-BrdU antibodies. This dynamic approach yields information complementing that provided by cellular RNA content analysis...

  19. DEA 1 expression on dog erythrocytes analyzed by immunochromatographic and flow cytometric techniques.

    Science.gov (United States)

    Acierno, M M; Raj, K; Giger, U

    2014-01-01

    The Dog erythrocyte antigen (DEA) 1 blood group system was thought to contain types DEA 1.1 and 1.2 (and possibly 1.3 [A3]). However, DEA 1.2+ dogs are very rare and newer typing methods reveal varying degrees of DEA 1 positivity. To assess if variation in DEA 1 positivity is because of quantitative differences in surface antigen expression. To determine expression patterns in dogs over time and effects of blood storage (4°C). To evaluate DEA 1.2+ samples by DEA 1 typing methods. Anticoagulated blood samples from 66 dogs in a research colony and from a hospital, and 9 previously typed DEA 1.2+ dogs from an animal blood bank. Research study: Samples were analyzed by flow cytometry and immunochromatographic strip using a monoclonal anti-DEA 1 antibody. Twenty dogs were DEA 1-, whereas 46 dogs were weakly to strongly DEA 1+. Antigen quantification revealed excellent correlation between strip and flow cytometry (r = 0.929). Both methods reclassified DEA 1.2+ samples as weakly to moderately DEA 1+, but they were not retyped with the polyclonal anti-DEA 1.1/1.X antibodies. Dogs and blood samples retained their relative DEA 1 antigen densities over time. The blood group system DEA 1 is a continuum from negative to strongly positive antigen expression. Previously typed DEA 1.2+ appears to be DEA 1+. These findings further the understanding of the DEA 1 system and suggest that all alleles within the DEA 1 system have a similarly based epitope recognized by the monoclonal antibody. Copyright © 2014 by the American College of Veterinary Internal Medicine.

  20. Development of a novel flow cytometric approach to evaluate fish sperm chromatin using fixed samples

    Science.gov (United States)

    Jenkins, Jill A.

    2013-01-01

    The integrity of the paternal DNA is essential for the accurate transmission of genetic information, yet fertilization is not inhibited by chromatin breakage. Some methods are available for the sensitive detection of DNA damage and can be applied in studies of environmental toxicology, carcinogenesis, aging, and assisted reproduction techniques in both clinical and experimental settings. Because semen samples obtained from remote locations undergo chromatin damage prior to laboratory assessment, the present study was undertaken to evaluate treatments for effective chromatin staining in the development of a DNA fragmentation assay using fixed milt from yellow perch (Perca flavescens). Similar to the sperm chromatin structure assay (SCSA), susceptibility of nuclear DNA to acid-induced denaturation was measured by flow cytometry (FCM). Use of 10% buffered formalin for milt fixation allowed easier peak discrimination than 4% paraformaldehyde. The effects of time and temperature of incubation in 0.08 N HCl were evaluated in order to determine the ideal conditions for promoting DNA decondensation and making strand breaks more available for staining and detection by FCM. The best results were obtained with incubation at 37°C for 1 minute, followed by cold propidium iodide staining for 30 minutes.

  1. Color encoded microbeads-based flow cytometric immunoassay for polycyclic aromatic hydrocarbons in food

    International Nuclear Information System (INIS)

    Meimaridou, Anastasia; Haasnoot, Willem; Noteboom, Linda; Mintzas, Dimitrios; Pulkrabova, Jana; Hajslova, Jana; Nielen, Michel W.F.

    2010-01-01

    Food contamination caused by chemical hazards such as persistent organic pollutants (POPs) is a worldwide public health concern and requires continuous monitoring. The chromatography-based analysis methods for POPs are accurate and quite sensitive but they are time-consuming, laborious and expensive. Thus, there is a need for validated simplified screening tools, which are inexpensive, rapid, have automation potential and can detect multiple POPs simultaneously. In this study we developed a flow cytometry-based immunoassay (FCIA) using a color-encoded microbeads technology to detect benzo[a]pyrene (BaP) and other polycyclic aromatic hydrocarbons (PAHs) in buffer and food extracts as a starting point for the future development of rapid multiplex assays including other POPs in food, such as polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs). A highly sensitive assay for BaP was obtained with an IC 50 of 0.3 μg L -1 using a monoclonal antibody (Mab22F12) against BaP, similar to the IC 50 of a previously described enzyme-linked immunosorbent assay (ELISA) using the same Mab. Moreover, the FCIA was 8 times more sensitive for BaP compared to a surface plasmon resonance (SPR)-based biosensor immunoassay (BIA) using the same reagents. The selectivity of the FCIAs was tested, with two Mabs against BaP for 25 other PAHs, including two hydroxyl PAH metabolites. Apart from BaP, the FCIAs can detect PAHs such as indenol[1,2,3-cd]pyrene (IP), benz[a]anthracene (BaA), and chrysene (CHR) which are also appointed by the European Food Safety Authority (EFSA) as suitable indicators of PAH contamination in food. The FCIAs results were in agreement with those obtained with gas chromatography-mass spectrometry (GC-MS) for the detection of PAHs in real food samples of smoked carp and wheat flour and has great potential for the future routine application of this assay in a simplex or multiplex format in combination with simplified extraction procedure which are

  2. Development of gammabeta thymocyte subsets during prenatal and postnatal ontogeny: a flow cytometric study in miniature pigs

    Czech Academy of Sciences Publication Activity Database

    Šinkora, Marek; Šinkorová, J.

    2003-01-01

    Roč. 87, č. 1 (2003), s. 101 ISSN 0165-2478 R&D Projects: GA ČR GA524/01/0919 Institutional research plan: CEZ:AV0Z5020903 Keywords : thymocyte subsets * cytometric Subject RIV: EE - Microbiology, Virology Impact factor: 1.710, year: 2003

  3. Development of a flow cytometric method to analyze subpopulations of bacteria in probiotic products and dairy starters

    NARCIS (Netherlands)

    Bunthof, C.J.; Abee, T.

    2002-01-01

    Flow cytometry (FCM) is a rapid and sensitive technique that can determine cell numbers and measure various physiological characteristics of individual cells by using appropriate fluorescent probes. Previously, we developed an FCM assay with the viability probes carboxyfluorescein diacetate (cFDA)

  4. Challenges of flow-cytometric estimation of nuclear genome size in orchids, a plant group with both whole-genome and progressively partial endoreplication.

    Science.gov (United States)

    Trávníček, Pavel; Ponert, Jan; Urfus, Tomáš; Jersáková, Jana; Vrána, Jan; Hřibová, Eva; Doležel, Jaroslav; Suda, Jan

    2015-10-01

    Nuclear genome size is an inherited quantitative trait of eukaryotic organisms with both practical and biological consequences. A detailed analysis of major families is a promising approach to fully understand the biological meaning of the extensive variation in genome size in plants. Although Orchidaceae accounts for ∼10% of the angiosperm diversity, the knowledge of patterns and dynamics of their genome size is limited, in part due to difficulties in flow cytometric analyses. Cells in various somatic tissues of orchids undergo extensive endoreplication, either whole-genome or partial, and the G1-phase nuclei with 2C DNA amounts may be lacking, resulting in overestimated genome size values. Interpretation of DNA content histograms is particularly challenging in species with progressively partial endoreplication, in which the ratios between the positions of two neighboring DNA peaks are lower than two. In order to assess distributions of nuclear DNA amounts and identify tissue suitable for reliable estimation of nuclear DNA content, we analyzed six different tissue types in 48 orchid species belonging to all recognized subfamilies. Although traditionally used leaves may provide incorrect C-values, particularly in species with progressively partial endoreplication, young ovaries and pollinaria consistently yield 2C and 1C peaks of their G1-phase nuclei, respectively, and are, therefore, the most suitable parts for genome size studies in orchids. We also provide new DNA C-values for 22 orchid genera and 42 species. Adhering to the proposed methodology would allow for reliable genome size estimates in this largest plant family. Although our research was limited to orchids, the need to find a suitable tissue with dominant 2C peak of G1-phase nuclei applies to all endopolyploid species. © 2015 International Society for Advancement of Cytometry.

  5. A novel and easy FxCycle™ violet based flow cytometric method for simultaneous assessment of DNA ploidy and six-color immunophenotyping.

    Science.gov (United States)

    Tembhare, Prashant; Badrinath, Yajamanam; Ghogale, Sitaram; Patkar, Nikhil; Dhole, Nilesh; Dalavi, Pooja; Kunder, Nikesh; Kumar, Ashok; Gujral, Sumeet; Subramanian, P G

    2016-03-01

    Abnormal DNA ploidy is a valuable prognostic factor in many neoplasms, especially in hematological neoplasms like B-cell acute lymphoblastic leukemia (B-ALL) and multiple myeloma (MM). Current methods of flow-cytometric (FC) DNA-ploidy evaluation are either technically difficult or limited to three- to four-color immunophenotyping and hence, challenging to evaluate DNA-ploidy in minute tumor population with background rich of its normal counterpart cells and other hematopoietic cells. We standardized a novel sensitive and easy method of simultaneous evaluation of six- to seven-color immunophenotyping and DNA-ploidy using a dye-FxCycle Violet (FCV). Linearity, resolution, and coefficient of variation (CV) for FCV were studied using chicken erythrocyte nuclei. Ploidy results of FCV were compared with Propidium iodide (PI) in 20 samples and intra-assay variation for FCV was studied. Using this six-color immunophenotyping & FCV-protocol DNA-ploidy was determined in bone-marrow samples from 124 B-ALL & 50 MM patients. Dilution experiment was also conducted to determine the sensitivity in detection of aneuploidy in minute tumor population. FCV revealed high linearity and resolution in 450/50 channel. On comparison with PI, CV of Go/G1-peak with FCV (mean-CV 4.1%) was slightly higher than PI (mean-CV 2.9%) but had complete agreement in ploidy results. Dilution experiment showed that aneuploidy could be accurately detected up to the limit of 0.01% tumor cells. Intra-assay variation was very low with CV of 0.005%. In B-ALL, hypodiploidy was noted in 4%, hyperdiploidy in 24%, near-hyperdiploidy in 13% and remaining 59% were diploid. In MM, hypodiploidy was in 2%, hyperdiploidy in 58%, near-hyperdiploidy in 8% and remaining 30% were diploid. FCV-based DNA-ploidy method is a sensitive and easy method for simultaneous evaluation of six-color immunophenotyping and DNA analysis. It is useful in DNA-ploidy evaluation of minute tumor population in cases like minimal residual

  6. Flow cytometric sexing of spider sperm reveals an equal sperm production ratio in a female-biased species

    DEFF Research Database (Denmark)

    Vanthournout, Bram; Deswarte, K; Hammad, H

    2014-01-01

    that other factors influence sex ratio variation. In this paper, we investigate whether this additional variation can be explained by the unequal production of male- and female-determining sperm cells during sperm production. Using flow cytometry, we show that males produce equal amounts of male- and female......-determining sperm cells; thus bias in sperm production does not contribute to the sex ratio bias observed in this species. This demonstrates that other factors such as parental genes suppressing endosymbiont effects and cryptic female choice might play a role in sex allocation in this species....

  7. Development of a flow cytometric bead immunoassay and its assessment as a possible aid to potency evaluation of enterotoxaemia vaccines

    Directory of Open Access Journals (Sweden)

    Angela Buys

    2014-03-01

    Full Text Available Enterotoxaemia, an economically important disease of sheep, goats and calves, is caused by systemic effects of the epsilon toxin produced by the anaerobic bacterium Clostridium perfringens type D. The only practical means of controlling the occurrence of enterotoxaemia is to immunise animals by vaccination. The vaccine is prepared by deriving a toxoid from the bacterial culture filtrate and the potency of the vaccine is tested with the in vivo mouse neutralisation test (MNT. Due to ethical, economic and technical reasons, alternative in vitro assays are needed. In this study an indirect cytometric bead immunoassay (I-CBA was developed for use in vaccine potency testing and the results were compared with those obtained using an indirect enzyme-linked immunosorbent assay (I-ELISA and the MNT. Sera were collected from guinea pigs immunised with three different production batches of enterotoxaemia vaccine and the levels of anti-epsilon toxin antibodies were determined. Although the intra- and inter-assay variability was satisfactory, epsilon antitoxin levels determined by both the I-ELISA and indirect cytometric bead immunoassay (I-CBA tests were higher than those of the MNT assay. In contrast to the MNT, all of the serum samples were identified as having antitoxin levels above the required minimum (not less than 5 U/mL. These results indicate that the respective in vitro tests in their current formats are not yet suitable alternatives to the in vivo MNT. The growing demand for a more humane, cost-effective and efficient method for testing the potency of enterotoxaemia vaccines, however, provides a strong impetus for further optimisation and standardisation of the I-CBA assay but further analytical research is required.

  8. An extended leukocyte differential count (16 types of circulating leukocytes) using the CytoDiff flow cytometric system can provide information for the discrimination of sepsis severity and prediction of outcome in sepsis patients.

    Science.gov (United States)

    Park, Sang Hyuk; Park, Borae G; Park, Chan-Jeoung; Kim, Sue; Kim, Duck-Hee; Jang, Seongsoo; Hong, Suk-Kyung; Chi, Hyun-Sook

    2014-07-01

    The Beckman Coulter CytoDiff flow cytometric system (Beckman Coulter, Miami, FL) was recently developed for performing leukocyte differential counts in up to 16 leukocyte subpopulations. We compared these leukocyte subpopulation levels among patients with three stages of sepsis (uncomplicated sepsis, severe sepsis, septic shock), especially focused on the discrimination of complicated sepsis from uncomplicated sepsis. We examined a total of 181 samples with sepsis who were admitted to the surgical intensive care unit. In addition, we examined samples obtained from 60 normal healthy volunteers. Both the proportions and absolute numbers of each cell type in the four groups were obtained using the CytoDiff flow cytometric system and compared. Mature neutrophils and immature granulocytes failed to discriminate patients with complicated sepsis from those with uncomplicated sepsis although their absolute numbers were increased compared with normal controls. In contrast, almost all lymphocyte subpopulations and CD16(-) monocytes decreased significantly in patients with complicated sepsis compared with uncomplicated sepsis. Among them, only B lymphocytes showed independent ability to discriminate two groups. Both B lymphocytes and CD16(-) monocytes possessed a significant adverse prognostic impact on overall survival when their absolute numbers decreased. Almost all lymphocyte subpopulations and CD16(-) monocytes decrease in size with increasing sepsis severity. Among them, only B lymphocytes showed independent ability to discriminate patients with complicated sepsis from those with uncomplicated sepsis. Both B lymphocytes and CD16 (-) monocytes show a significant adverse prognostic impact on overall survival outcomes in sepsis patients when their absolute numbers are decreased. Copyright © 2013 Clinical Cytometry Society.

  9. An extended leukocyte differential count (16 types of circulating leukocytes) using the cytodiff flow cytometric system can provide informations for the discrimination of sepsis severity and prediction of outcome in sepsis patients.

    Science.gov (United States)

    Park, Sang Hyuk; Park, Borae G; Park, Chan-Jeoung; Kim, Sue; Kim, Duck-Hee; Jang, Seongsoo; Hong, Suk-Kyung; Chi, Hyun-Sook

    2013-08-20

    Background: The Beckman Coulter CytoDiff flow cytometric system (Beckman Coulter, Miami, FL, USA) was recently developed for performing leukocyte differential counts in up to 16 leukocyte subpopulations. We compared these leukocyte subpopulation levels among patients with three stages of sepsis (uncomplicated sepsis, severe sepsis, septic shock), especially focused on the discrimination of complicated sepsis from uncomplicated sepsis. Methods: We examined a total of 181 samples with sepsis who were admitted to the surgical intensive care unit. In addition, we examined samples obtained from 60 normal healthy volunteers. Both the proportions and absolute numbers of each cell type in the four groups were obtained using the CytoDiff flow cytometric system and compared. Results: Mature neutrophils and immature granulocytes failed to discriminate patients with complicated sepsis from those with uncomplicated sepsis although their absolute numbers were increased compared with normal controls. In contrast, almost all lymphocyte subpopulations and CD16(-) monocytes decreased significantly in patients with complicated sepsis compared with uncomplicated sepsis. Among them, only B lymphocytes showed independent ability to discriminate two groups. Both B lymphocytes and CD16(-) monocytes possessed a significant adverse prognostic impact on overall survival when their absolute numbers decreased. Conclusions: Almost all lymphocyte subpopulations and CD16(-) monocytes decrease in size with increasing sepsis severity. Among them, only B lymphocytes showed independent ability to discriminate patients with complicated sepsis from those with uncomplicated sepsis. Both B lymphocytes and CD16(-) monocytes show a significant adverse prognostic impact on overall survival outcomes in sepsis patients when their absolute numbers are decreased. © 2013 Clinical Cytometry Society. Copyright © 2013 Clinical Cytometry Society.

  10. Flow Cytometric Clinical Immunomonitoring Using Peptide–MHC Class II Tetramers: Optimization of Methods and Protocol Development

    Directory of Open Access Journals (Sweden)

    Diahann T. S. L. Jansen

    2018-01-01

    Full Text Available With the advent of novel strategies to induce tolerance in autoimmune and autoimmune-like conditions, clinical trials of antigen-specific tolerizing immunotherapy have become a reality. Besides safety, it will be essential to gather mechanistic data on responding CD4+ T cells to assess the effects of various immunomodulatory approaches in early-phase trials. Peptide–MHC class II (pMHCII multimers are an ideal tool for monitoring antigen-specific CD4+ T cell responses in unmanipulated cells directly ex vivo. Various protocols have been published but there are reagent and assay limitations across laboratories that could hinder their global application to immune monitoring. In this methodological analysis, we compare protocols and test available reagents to identify sources of variability and to determine the limitations of the tetramer binding assay. We describe a robust pMHCII flow cytometry-based assay to quantify and phenotype antigen-specific CD4+ T cells directly ex vivo from frozen peripheral blood mononuclear cell samples, which we suggest should be tested across various laboratories to standardize immune-monitoring results.

  11. Flow cytometric method for enumeration and characterization of newly released polymorphonuclear leukocytes from the bone marrow using 5'-bromo-2'-deoxyuridine.

    Science.gov (United States)

    Shih, Chih-Horng; Whalen, Beth A; Goto, Yukinobu; Hogg, James C; van Eeden, Stephan F

    2005-09-01

    Inflammation accelerates polymorphonuclear leukocyte (PMN) release from the bone marrow, and these PMNs are implicated in inappropriate tissue injury. We have previously developed a method using 5'-bromo-2'-deoxyuridine (BrdU) to study PMN kinetics using an immunocytochemical grading system of PMN on cytospin slides. The aim of this study was to develop a flow cytometric method to quantify the number of positively stained PMN and grade the intensity of staining for the transit time calculation of PMN through the marrow. Dividing myeloid progenitors in the marrow of rabbits were labeled with a pulse dosage of intravenous BrdU. BrdU-labeled PMN (PMN(BrdU)) were detected in the circulation using a FITC-conjugated anti-BrdU monoclonal antibody. The PMN(BrdU) were assigned to five groups according to their FITC intensity, and the transit times of PMN at different stages of development in the marrow were calculated. Results were compared using parallel immunocytochemical analysis of the same samples. In control animals, PMN(BrdU) in the circulation peaked at 72 h after BrdU labeling with 36.0% of PMN labeled. In normal rabbits, the transit times of PMN through the mitotic pool (49.5 +/- 4.2 h) and maturation pool (65.5 +/- 3.1 h) correlated well with immunocytochemical analysis and previously published values. Using this method, we demonstrated that exposure to air pollution particles accelerates the release of PMN(BrdU) from the marrow. We conclude that a flow cytometric approach for identifying BrdU-labeled leukocytes provides an objective and accurate method for studying leukocyte kinetics and behavior.

  12. Enumeration of extracellular vesicles by a new improved flow cytometric method is comparable to fluorescence mode nanoparticle tracking analysis.

    Science.gov (United States)

    Pasalic, Leonardo; Williams, Rebekka; Siupa, Agnieszka; Campbell, Heather; Henderson, Michelle J; Chen, Vivien M Y

    2016-05-01

    Extracellular vesicles (EVs) play a role in a variety of physiological and pathological processes. However, use of EVs as biomarkers has been hampered by limitations of current detection and enumeration methods. We compared fluorescence-threshold flow cytometry (FT-FC) to nanoparticle tracking analysis (NTA) for enumeration of cell culture-derived EVs. FT-FC and NTA utilising fluorescence mode (F-NTA) enumerated similar numbers of EVs stained with a membrane dye PKH67. Both methods were sufficiently sensitive to detect cell-derived EVs above the background of culture medium. Light scatter NTA (LS-NTA) detected 10-100× more particles than either fluorescence-based method but demonstrated poor specificity. F-NTA appeared to have better sensitivity for vesicles, however, the FT-FC method combined direct enumeration of EVs with high sensitivity and specificity in the >100nm range. Due to wider availability and higher degree of automation and standardisation, FT-FC is a reasonable surrogate to F-NTA for quantification of EVs. Extracellular vesicles are small particles, which can act as tools for intercellular communication. One recent area of interest in EVs is their potentials as biomarkers. In this article, the authors investigated and compared fluorescence-threshold flow cytometry (FT-FC) to nanoparticle tracking analysis (NTA) for the detection of EVs and showed that FT- FC method could be more advantageous. This technique should provide a new alternative for the future. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  13. Influence of a radioprotector WR-638 on the lymphoid compartment of the irradiated rat thymus: a flow cytometric analysis

    International Nuclear Information System (INIS)

    Dragojevic-Simic, V.; Colic, M.; Gasic, S.

    1994-01-01

    The T cell composition of the thymus of X-ray irradiated (3.5 Gy) Wistar rat protected with WR-638 was analyzed by flow cytometry using monoclonal antibodies directed to the Thy 1.1, CD43, CD2, CD5, CD4, CD8 and class I and II MHC antigens. It was shown that this dose of X-rays caused cyclic changes in thymic cellularity manifested as: primary involution (until day 2), primary regeneration (from days 2 to 14), secondary involution (from days 14 to 21) and secondary regeneration (from days 21 to 30). WR-638 reduced the magnitude of thymocyte depletion in the primary involutive phase of the irradiated thymi. (author)

  14. Transmission electron microscopic morphological study and flow cytometric viability assessment of Acinetobacter baumannii susceptible to Musca domestica cecropin.

    Science.gov (United States)

    Gui, Shuiqing; Li, Rongjiang; Feng, Yongwen; Wang, Sanming

    2014-01-01

    Multidrug-resistant (MDR) Acinetobacter baumannii infections are difficult to treat owing to the extremely limited armamentarium. Expectations about antimicrobial peptides' use as new powerful antibacterial agents have been raised on the basis of their unique mechanism of action. Musca domestica cecropin (Mdc), a novel antimicrobial peptide from the larvae of Housefly (Musca domestica), has potently active against Gram-positive and Gram-negative bacteria standard strain. Here we evaluated the antibacterial activity of Mdc against clinical isolates of MDR-A. baumannii and elucidate the related antibacterial mechanisms. The minimal inhibitory concentration (MIC) of Mdc was 4 μg/mL. Bactericidal kinetics of Mdc revealed rapid killing of A. baumannii (30 min). Flow cytometry using viability stain demonstrated that Mdc causes A. baumannii membrane permeabilization in a concentration- and time-dependent process, which correlates with the bactericidal action. Moreover, transmission electron microscopic (TEM) examination showed that Mdc is capable of disrupting the membrane of bacterial cells, resulting in efflux of essential cytoplasmic components. Overall, Mdc could be a promising antibacterial agent for MDR-A. baumannii infections.

  15. Transmission Electron Microscopic Morphological Study and Flow Cytometric Viability Assessment of Acinetobacter baumannii Susceptible to Musca domestica cecropin

    Directory of Open Access Journals (Sweden)

    Shuiqing Gui

    2014-01-01

    Full Text Available Multidrug-resistant (MDR Acinetobacter baumannii infections are difficult to treat owing to the extremely limited armamentarium. Expectations about antimicrobial peptides' use as new powerful antibacterial agents have been raised on the basis of their unique mechanism of action. Musca domestica cecropin (Mdc, a novel antimicrobial peptide from the larvae of Housefly (Musca domestica, has potently active against Gram-positive and Gram-negative bacteria standard strain. Here we evaluated the antibacterial activity of Mdc against clinical isolates of MDR-A. baumannii and elucidate the related antibacterial mechanisms. The minimal inhibitory concentration (MIC of Mdc was 4 μg/mL. Bactericidal kinetics of Mdc revealed rapid killing of A. baumannii (30 min. Flow cytometry using viability stain demonstrated that Mdc causes A. baumannii membrane permeabilization in a concentration- and time-dependent process, which correlates with the bactericidal action. Moreover, transmission electron microscopic (TEM examination showed that Mdc is capable of disrupting the membrane of bacterial cells, resulting in efflux of essential cytoplasmic components. Overall, Mdc could be a promising antibacterial agent for MDR-A. baumannii infections.

  16. The combination of kinetic and flow cytometric semen parameters as a tool to predict fertility in cryopreserved bull semen.

    Science.gov (United States)

    Gliozzi, T M; Turri, F; Manes, S; Cassinelli, C; Pizzi, F

    2017-11-01

    Within recent years, there has been growing interest in the prediction of bull fertility through in vitro assessment of semen quality. A model for fertility prediction based on early evaluation of semen quality parameters, to exclude sires with potentially low fertility from breeding programs, would therefore be useful. The aim of the present study was to identify the most suitable parameters that would provide reliable prediction of fertility. Frozen semen from 18 Italian Holstein-Friesian proven bulls was analyzed using computer-assisted semen analysis (CASA) (motility and kinetic parameters) and flow cytometry (FCM) (viability, acrosomal integrity, mitochondrial function, lipid peroxidation, plasma membrane stability and DNA integrity). Bulls were divided into two groups (low and high fertility) based on the estimated relative conception rate (ERCR). Significant differences were found between fertility groups for total motility, active cells, straightness, linearity, viability and percentage of DNA fragmented sperm. Correlations were observed between ERCR and some kinetic parameters, and membrane instability and some DNA integrity indicators. In order to define a model with high relation between semen quality parameters and ERCR, backward stepwise multiple regression analysis was applied. Thus, we obtained a prediction model that explained almost half (R 2=0.47, Pfertility. Once the accuracy of fertility prediction has been confirmed, the model developed in the present study could be used by artificial insemination centers for bull selection or for elimination of poor fertility ejaculates.

  17. Cytometric comparisons between circulating tumor cells from prostate cancer patients and the prostate-tumor-derived LNCaP cell line

    Science.gov (United States)

    Lazar, Daniel C.; Cho, Edward H.; Luttgen, Madelyn S.; Metzner, Thomas J.; Loressa Uson, Maria; Torrey, Melissa; Gross, Mitchell E.; Kuhn, Peter

    2012-02-01

    Many important experiments in cancer research are initiated with cell line data analysis due to the ease of accessibility and utilization. Recently, the ability to capture and characterize circulating tumor cells (CTCs) has become more prevalent in the research setting. This ability to detect, isolate and analyze CTCs allows us to directly compare specific protein expression levels found in patient CTCs to cell lines. In this study, we use immunocytochemistry to compare the protein expression levels of total cytokeratin (CK) and androgen receptor (AR) in CTCs and cell lines from patients with prostate cancer to determine what translational insights might be gained through the use of cell line data. A non-enrichment CTC detection assay enables us to compare cytometric features and relative expression levels of CK and AR by indirect immunofluorescence from prostate cancer patients against the prostate cancer cell line LNCaP. We measured physical characteristics of these two groups and observed significant differences in cell size, fluorescence intensity and nuclear to cytoplasmic ratio. We hope that these experiments will initiate a foundation to allow cell line data to be compared against characteristics of primary cells from patients.

  18. Flow cytogenetic studies in chromosomes and whole cells for the detection of clastogenic effects

    International Nuclear Information System (INIS)

    Otto, F.J.; Oldiges, H.

    1980-01-01

    Flow cytometric measurements of the chromosomal DNA content have been used to develop a screening method for the detection of chemically- or physically-induced cytogenetic damage. The reproducibility of this flow cytogenetic assay was shown in a series of subcultures of a Chinese hamster cell clone. The accuracy and sensitivity was tested in cultures treated with chemical mutagens and x-rays. The clastogenic effectiveness was quantified and the dose-effect relationship was established by the increase of the coefficient of variation of the peak of the largest chromosome type in the flow histograms. Since structural chromosome aberrations cause an unequal division of the DNA at mitosis, it is expected that clastogenic effects can be detected also in whole cells of growing populations as an increased dispersion of the cellular DNA content. In order to test this feature, high resolution flow cytometric measurements were performed in x-irradiated hamster cells in vitro and mouse bone marrow cells in vivo

  19. Commercially Available Antibodies to Human Tumour Necrosis Factor-α Tested for Cross-Reactivity with Ovine and Bovine Tumour Necrosis Factor-α using Flow Cytometric Assays

    Directory of Open Access Journals (Sweden)

    Waller K Persson

    2004-06-01

    Full Text Available A thorough understanding of the immune system, including the role of different cytokines, during inflammatory diseases in ruminants could lead to the development of new diagnostic methods and treatments. Tumour necrosis factor-α (TNF-α is an important cytokine in the onset of the inflammatory responses. Unfortunately, the number of studies on cytokines, like TNF-α, in ruminants is limited due to a lack of species-specific reagents. As cytokines have remained rather conserved during evolution, cross-reactivity between animal species may occur. Therefore, the aim of the present study was to investigate 5 commercially available antibodies against human TNF-α for their ability to cross-react with ovine and/or bovine TNF-α, using a bead-based flow cytometric method. Two of the antibody clones (Mab 11 and 6401.1111 showed cross reactivity with ovine recombinant TNF-α in concentrations above 2.5 ng/ml. However, none of the antibodies detected TNF-α in bovine milk, or serum containing known concentrations of bovine TNF-α, as earlier determined with ELISA. The results could be due to inability of the antibodies to cross-react between species, but quenching of the signal by matrix proteins might also have lowered the response.

  20. Response of Syngonium podophyllum L. ‘White Butterfly’ shoot cultures to alternative media additives and gelling agents, and flow cytometric analysis of regenerants

    Directory of Open Access Journals (Sweden)

    JAIME A. TEIXEIRA DA SILVA

    2015-05-01

    Full Text Available Abstract. Teixeira da Silva JA. 2015. Response of Syngonium podophyllum L. ‘White Butterfly’ shoot cultures to alternative media additives and gelling agents, and flow cytometric analysis of regenerants. Nusantara Bioscience 7: 26-32. Syngonium podophyllum L. (arrowhead vine is a popular leafy indoor pot plant whose tissue culture has been established, primarily through in vitro shoot culture, but several interesting aspects have not yet been explored. In this study, cv. ‘White Butterfly’ was used to investigate the response of shoot formation to alternative gelling agents and media additives. Gellan gum (Gelrite® at 2 g/L resulted in greater leaf production, plantlet fresh weight and higher chlorophyll content (SPAD value than all other gelling agents tested, including agar, Bacto agar, phytagel, oatmeal agar, potato dextrose agar, barley starch and corn starch, when on a basal Hyponex® (NPK = 6.5: 6: 19; 3 g/L medium. Several alternative liquid medium additives tested (low and full fat milk, Coca-Cola®, coffee, Japanese green, Oolong and Darjeeling teas negatively impacted plant growth, stunted roots and decreased chlorophyll content (SPAD value of leaves. Plant growth on medium with refined sucrose or table sugar responded similarly. Poor growth was observed when crude extract from a high rebaudioside-containing stevia (Stevia rebaudiana Bertoni line - an artificial sweetener - was used. Leaf tissue from the control did not show any endopolyploidy but low levels of endopolyploidy (8C were detected in some treatments.

  1. Effect of chronic pesticide exposure on murine cornea: a histopathological, cytological and flow cytometric approach to study ocular damage by xenobiotics.

    Science.gov (United States)

    Sanyal, Shalini; Das, Prosun; Law, Sujata

    2016-02-01

    Pesticide exposure can occur directly or indirectly in an occupational setting or otherwise. The health hazards of pesticides have long been studied; however, little is known about the ocular insult of these potent chemicals. In this study, we examined the consequences of long-term pesticide exposure on the ocular tissue in animal model with special focus on the cornea. Swiss Albino mice were sacrificed to obtain the eye globes and various cytological, cytotoxic and histological evaluations, in vitro growth kinetic studies and flow cytometric analyses of select cytokeratins were performed to determine the structural and functional damage due to pesticide exposure. Our study revealed the detrimental impact of this xenobiotic insult by cataloguing the damage to each layer of the cornea wherein it was discovered that all the functional layers as well as the membranes were compromised. We hope that our investigation will pave the way for future studies in this oft overlooked area of affront caused by pesticide exposure to the ocular surface.

  2. Flow cytometric analysis of variation in the level of nuclear DNA endoreduplication in the cotyledons amongst Vigna radiata cultivars

    Czech Academy of Sciences Publication Activity Database

    Pal, A.; Vrána, Jan; Doležel, Jaroslav

    2004-01-01

    Roč. 57, č. 3 (2004), s. 262-266 ISSN 0008-7114 R&D Projects: GA AV ČR IBS5038104 Grant - others:Indian National Science Academy(IN) INSA Institutional research plan: CEZ:AV0Z5038910 Keywords : Cotyledon * endoreduplication * flow cytometry Subject RIV: GE - Plant Breeding Impact factor: 0.366, year: 2004

  3. Flow cytometric and microscopic analysis of the effect of tannic acid on plant nuclei and estimation of DNA content

    Czech Academy of Sciences Publication Activity Database

    Loureiro, J.; Rodriguez, E.; Doležel, Jaroslav; Santos, C.

    2006-01-01

    Roč. 98, - (2006), s. 515-527 ISSN 0305-7364 R&D Projects: GA MŠk(CZ) LC06004 Institutional research plan: CEZ:AV0Z50380511 Keywords : genome size * flow cytometry * nuclear DNA content Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 2.448, year: 2006

  4. A 'fragile cell' sub-population revealed during cytometric assessment of Saccharomyces cerevisiae viability in lipid-limited alcoholic fermentation.

    Science.gov (United States)

    Delobel, P; Pradal, M; Blondin, B; Tesniere, C

    2012-11-01

    To show that in anaerobic fermentation with limiting lipid nutrients, cell preparation impacts the viability assessment of yeast cells, and to identify the factors involved. Saccharomyces cerevisiae viability was determined using propidium iodide staining and the flow cytometry. Analyses identified intact cells, dead cells and, under certain conditions, the presence of a third subpopulation of apparently damaged cells. This intermediate population could account for up to 40% of the entire cell population. We describe, analyse and discuss the effects of different solutions for cell resuspension on the respective proportion of these three populations, in particular that of the intermediate population. We show that this intermediate cell population forms in the absence of Ca(2+)/Mg(2+). Cell preparation significantly impacts population viability assessment by FCM. The intermediate population, revealed under certain conditions, could be renamed as 'fragile cells'. For these cells, Ca(2+) and Mg(2+) reduce cell membrane permeability to PI. This is the first study that analyses and discusses the factors influencing the formation of an intermediate population when studying viability in yeast alcoholic fermentation. With a wider application in biological research, this study provides important support to the relatively new questioning of propidium iodide staining as a universal cell death indicator. © 2012 The Authors. Letters in Applied Microbiology © 2012 The Society for Applied Microbiology.

  5. Immuno-flow cytometric detection of the ichthyotoxic dinoflagellates Gyrodinium aureolum and Gymnodinium nagasakiense : Independence of physiological state

    NARCIS (Netherlands)

    Vrieling, EG; vandePoll, WH; Vriezekolk, G; Gieskes, WWC

    The ichthyotoxic dinoflagellates Gyrodinium aureolum and Gymnodinium nagasakiense were cultured under different environmental conditions to test possible variability in immunochemical labelling intensity of cell-surface antigens using species-specific monoclonal antibodies. Variation of antigen

  6. PATHOMORPHOLOGICAL AND CYTOMETRIC PARAMETERS OF BLOOD RED CELLS OF AGE-2 PRUSSIAN CARP (CARASSIUS AURATUS GIBELIO (BLOCH, 1782 IN THE CONDITIONS OF INTOXICATION WITH COPPER IONS

    Directory of Open Access Journals (Sweden)

    T. Sharamok

    2017-09-01

    Full Text Available Purpose. To detect the effect of elevated copper ion concentrations (10 aquaculture Maximum Permissible Limits on morphological and cytometric parameters of erythrocytes of age-2 Prussian carp (Carassius gibelio Bloch, 1782 in experimental and natural conditions. Methodology. During the work, summarized results of studies performed in 2015-2016 were used. Morphological and cytometric parameters of Prussian carp erythrocytes were determined in the conditions of natural habitats (Zaporizhzhia reservoir and an experiment. Copper ion concentration both in the experiment and natural conditions was similar and was 0.01 mg/L (10 aquaculture Maximum Permissible Limits. Experimental studies were performed during 21 days. In the control aquarium, fish were kept in the settled tap water; while in the experimental aquaria, intoxication of fish with copper ions was modelled by introducing CuSO4 in water. Blood smears were examined under 40x and 100 x magnifications with the use of microphotography (digital camera Sciencelab T500 5.17 M. Findings. The performed hematological studies showed that under the conditions of experimental chronic intoxication with copper ions (0.01 mg/L, age-2 Prussian carp had an increase in the share of immature forms of erythrocytes, increase in the number of erythrocytes with pathological signs (cell wall destruction, atypical forms, increase in the nucleus-cytoplasm ration, but the difference in cytometric parameters of erythrocytes between experimental and control fish was not significant. When comparing the morphometric parameters of erythrocytes of fish kept in experimental and natural conditions with similar copper ion concentrations (0.01 mg/L, a significant increase in the nucleus areas of mature erythrocytes was detected and, correspondingly, an increase in the nucleus-cytoplasm ratio of erythrocytes (by almost 30% in fish in experimental conditions compared to fish, which lived in the Zaporizhzhia reservoir. An increase

  7. Simultaneous flow cytometric quantification of plant nuclear DNA contents over the full range of described angiosperm 2C values.

    Science.gov (United States)

    Galbraith, David W

    2009-08-01

    Flow cytometry provides a rapid, accurate, and simple means to determine nuclear DNA contents (C-value) within plant homogenates. This parameter is extremely useful in a number of applications in basic and applied plant biology; for example, it provides an important starting point for projects involving whole genome sequencing, it facilitates characterization of plant species within natural and agricultural settings, it allows facile identification of engineered plants that are euploid or that represent desired ploidy classes, it points toward studies concerning the role of C-value in plant growth and development and in response to the environment and in terms of evolutionary fitness, and, in uncovering new and unexpected phenomena (for example endoreduplication), it uncovers new avenues of scientific enquiry. Despite the ease of the method, C-values have been determined for only around 2% of the described angiosperm (flowering plant) species. Within this small subset, one of the most remarkable observations is the range of 2C values, which spans at least two orders of magnitude. In determining C-values for new species, technical issues are encountered which relate both to requirement for a method that can provide accurate measurements across this extended dynamic range, and that can accommodate the large amounts of debris which accompanies flow measurements of plant homogenates. In this study, the use of the Accuri C6 flow cytometer for the analysis of plant C-values is described. This work indicates that the unusually large dynamic range of the C6, a design feature, coupled to the linearity of fluorescence emission conferred by staining of nuclei using propidium iodide, allows simultaneous analysis of species whose C-values span that of almost the entire described angiosperms. Copyright 2009 International Society for Advancement of Cytometry.

  8. Improved flow cytometric identification of myelopoiesis by the simultaneous labelling with CD13, CD14 and CD66 monoclonal antibodies

    DEFF Research Database (Denmark)

    Bonde, J; Meyer, K; Broe, M K

    1996-01-01

    in the fast determination of remission state. In MDS, the immature myeloid component could be distinguished in patients defined according to the FAB classification with the possibility of identifying aberrant phenotypes, the assay should also be of interest in other myeloproliferative disorders. Moreover......The aim of the present study was to increase our knowledge of myelopoiesis evaluated by flow cytometry. We therefore designed a triple-marker assay employing monoclonal antibodies against the CD13 (immature), the CD14 (monocytic), and the CD66 (mature myeloid) antigens using three...

  9. Flow cytometric minimal residual disease monitoring in children with acute lymphoblastic leukemia treated by regimens with reduced intensity

    Directory of Open Access Journals (Sweden)

    A. M. Popov

    2015-01-01

    Full Text Available 191 consecutive unselected children with acute lymphoblastic leukemia aged from 1 to 16 years were enrolled in the study. Bone marrow samples were obtained at the time of initial diagnostics as well as at days 15 (n = 188, 36 (n = 191, and 85 (n = 187 of remission induction. Minimal residual disease (MRD was assessed by 6–10-color flow cytometry. Flow cytometry data at day 15 allowed distinguishing three patients groups with significantly different outcome (p ˂ 0.0001: 35.64 % patients with MRD < 0.1 % represented 5-year event-free survival (EFS of 100 %; 48.40 % cases with 0.1 % ≤ MRD< 10 % had EFS 84.6 ± 4.2 %; 15.96 % patients with very high MRD (≥ 10 % belonged to group with poor outcome (EFS 56.7 ± 9.0 %. At the end of remission induction (day 36 36 children (18.85 % with MRD higher than 0.1 % had significantly worse outcome compared to remaining ones (EFS 49.4 ± 9.0 and 93.5 ± 2.1 % respectively; p ˂ 0.0001. From a clinical standpoint it is relevant to evaluate both low-risk and high-risk criteria. Multivariate analysis showed that day 15 MRD data is better for low-risk patients definition while end-induction MRD is the strongest unfavorable prognostic factor.

  10. Genetic stock assessment of spawning arctic cisco (Coregonus autumnalis) populations by flow cytometric determination of DNA content.

    Science.gov (United States)

    Lockwood, S F; Bickham, J W

    1991-01-01

    Intraspecific variation in cellular DNA content was measured in five Coregonus autumnalis spawning populations from the Mackenzie River drainage, Canada, using flow cytometry. The rivers assayed were the Peel, Arctic Red, Mountain, Carcajou, and Liard rivers. DNA content was determined from whole blood preparations of fish from all rivers except the Carcajou, for which kidney tissue was used. DNA content measurements of kidney and blood preparations of the same fish from the Mountain River revealed statistically indistinguishable results. Mosaicism was found in blood preparations from the Peel, Arctic Red, Mountain, and Liard rivers, but was not observed in kidney tissue preparations from the Mountain or Carcajou rivers. The Liard River sample had significantly elevated mean DNA content relative to the other four samples; all other samples were statistically indistinguishable. Significant differences in mean DNA content among spawning stocks of a single species reinforces the need for adequate sample sizes of both individuals and populations when reporting "C" values for a particular species.

  11. Flow cytometric monitoring of bacterioplankton phenotypic diversity predicts high population-specific feeding rates by invasive dreissenid mussels.

    Science.gov (United States)

    Props, Ruben; Schmidt, Marian L; Heyse, Jasmine; Vanderploeg, Henry A; Boon, Nico; Denef, Vincent J

    2018-02-01

    Species invasion is an important disturbance to ecosystems worldwide, yet knowledge about the impacts of invasive species on bacterial communities remains sparse. Using a novel approach, we simultaneously detected phenotypic and derived taxonomic change in a natural bacterioplankton community when subjected to feeding pressure by quagga mussels, a widespread aquatic invasive species. We detected a significant decrease in diversity within 1 h of feeding and a total diversity loss of 11.6 ± 4.1% after 3 h. This loss of microbial diversity was caused by the selective removal of high nucleic acid populations (29 ± 5% after 3 h). We were able to track the community diversity at high temporal resolution by calculating phenotypic diversity estimates from flow cytometry (FCM) data of minute amounts of sample. Through parallel FCM and 16S rRNA gene amplicon sequencing analysis of environments spanning a broad diversity range, we showed that the two approaches resulted in highly correlated diversity measures and captured the same seasonal and lake-specific patterns in community composition. Based on our results, we predict that selective feeding by invasive dreissenid mussels directly impacts the microbial component of the carbon cycle, as it may drive bacterioplankton communities toward less diverse and potentially less productive states. © 2017 Society for Applied Microbiology and John Wiley & Sons Ltd.

  12. Flow cytometric investigations of diploid and tetraploid plants and in vitro cultures of Datura stramonium and Hyoscyamus niger.

    Science.gov (United States)

    Weber, Jost; Georgiev, Vasil; Pavlov, Atanas; Bley, Thomas

    2008-10-01

    Plant in vitro systems are valuable sources for the production of biological active substances. However, changed profiles of secondary metabolites, and low, variable yields possibly caused by genetic instabilities complicate their industrial implementation. DNA profiling of plant in vitro cultures may provide data for the selection of highly producing in vitro cultures. Diploid and tetraploid Datura stramonium and Hyoscyamus niger plant as well as calli, and hairy root lines derived from them were analyzed by flow cytometry. Plant in vitro cultures undergo several cycles of endoreduplication more than the explants from which they were obtained. The highest cycle values were observed in calli (e.g. 1.19 for diploid H. niger) possibly induced by the growth factors. However, hairy roots cultivated without growth factor exhibited significant degrees of endoreduplication (cycle value 0.88 for diploid H. niger). Sets of five hairy root lines from each plant and ploidy level showed consistent within-set ploidy patterns. The ploidy profiles of investigated plant in vitro and in vivo differ. For the first time we report that hairy roots of two Solanaceae species undergo endoreduplication. Theploidy profiles of in vitro cultures (hairy roots and calli) seem to be influenced by the genome size, the growth factors applied, and the type of in vitro culture. The transformation of several hairy root lines showed no differences in the ploidy patterns. Copyright 2008 International Society for Advancement of Cytometry.

  13. Flow cytometric analysis of pollen grains collected from individual bees provides information about pollen load composition and foraging behaviour.

    Science.gov (United States)

    Kron, Paul; Kwok, Allison; Husband, Brian C

    2014-01-01

    Understanding the species composition of pollen on pollinators has applications in agriculture, conservation and evolutionary biology. Current identification methods, including morphological analysis, cannot always discriminate taxa at the species level. Recent advances in flow cytometry techniques for pollen grains allow rapid testing of large numbers of pollen grains for DNA content, potentially providing improved species resolution. A test was made as to whether pollen loads from single bees (honey-bees and bumble-bees) could be classified into types based on DNA content, and whether good estimates of proportions of different types could be made. An examination was also made of how readily DNA content can be used to identify specific pollen species. The method allowed DNA contents to be quickly found for between 250 and 9391 pollen grains (750-28 173 nuclei) from individual honey-bees and between 81 and 11 512 pollen grains (243-34 537 nuclei) for bumble-bees. It was possible to identify a minimum number of pollen species on each bee and to assign proportions of each pollen type (based on DNA content) present. The information provided by this technique is promising but is affected by the complexity of the pollination environment (i.e. number of flowering species present and extent of overlap in DNA content). Nevertheless, it provides a new tool for examining pollinator behaviour and between-species or cytotype pollen transfer, particularly when used in combination with other morphological, chemical or genetic techniques.

  14. Studies of the ABO and FORS Histo-Blood Group Systems: Focus on Flow Cytometric and Genetic Analysis

    OpenAIRE

    Hult, Annika

    2013-01-01

    ABO is the clinically most important blood group system and its antigens are carbohydrate moieties present on the surface of the red blood cell (RBC) but also on other tissues throughout the body. The ABO gene encodes an enzyme, a glycosyltransferase (GT),that adds a terminal monosaccharide to the precursor structure, H antigen, to define the A or B antigens. Blood group O is due to a non-functional GT that leaves the precursor unchanged. Weak expression of ABO antigens can be acquired or be ...

  15. Cytometric characterization of circulating tumor cells captured by microfiltration and their correlation to the CellSearch(®) CTC test.

    Science.gov (United States)

    Adams, Daniel L; Stefansson, Steingrimur; Haudenschild, Christian; Martin, Stuart S; Charpentier, Monica; Chumsri, Saranya; Cristofanilli, Massimo; Tang, Cha-Mei; Alpaugh, R Katherine

    2015-02-01

    Recent studies reporting hundreds, to thousands, of circulating tumor cells (CTCs) in the blood of cancer patients have raised questions regarding the prevalence of CTCs, as enumerated by the CellSearch(®) CTC Test. Although CellSearch has been shown to consistently detect clinically relevant CTCs; the ability to only capture EpCAM positive cells has led to speculation that it captures limited subsets of CTCs. In contrast, alternative approaches to CTC isolation are often cited as capturing large numbers of CTCs from patient blood. Not surprisingly the number of cells isolated by alternative approaches show poor correlations when compared to CellSearch, even when accounting for EpCAM presence or absence. In an effort to address this discrepancy, we ran an exploratory method comparison study to characterize and compare the CTC subgroups captured from duplicate blood samples from 30 breast and prostate cancer patients using a microfiltration system (CellSieve™) and CellSearch. We then categorized the CellSieve Cytokeratin(CK)+/CD45-/DAPI+ cells into five morphologically distinct subpopulations for correlative analysis. Like other filtration techniques, CellSieve isolated greater numbers of CK+/CD45- cells than CellSearch. Furthermore, analysis showed low correlation between the total CK+/CD45- cells captured by these two assays, regardless of EpCAM presence. However, subgrouping of CK+/CD45-/DAPI+ cells based on distinct cytokeratin staining patterns and nuclear morphologies elucidated a subpopulation correlative to CellSearch. Using method comparison analyses, we identified a specific CTC morphology which is highly correlative between two distinct capture methods. These data suggests that although various morphologic CTCs with similar phenotypic expressions are present in the blood of cancer patients, the clinically relevant cells isolated by CellSearch can potentially be identified using non-EpCAM dependent isolation. © 2014 The Authors. Published by Wiley

  16. Corrigendum to "Flow cytometric quantitation of platelet phagocytosis by monocytes using a pH-sensitive dye, pHrodo-SE" [Journal of Immunological Methods 447 (2017) 57-64].

    Science.gov (United States)

    Takahashi, Daisuke; Fujihara, Mitsuhiro; Miyazaki, Toru; Matsubayashi, Keiji; Sato, Shinichiro; Azuma, Hiroshi; Kato, Toshiaki; Kino, Shuichi; Ikeda, Hisami; Takamoto, Shigeru; Sato, Noriyuki; Torigoe, Toshihiko

    2018-03-01

    Antibody-mediated phagocytosis of platelets using a flow cytometric monocyte-based phagocytosis assay (FMPA) has been shown to predict the outcome of platelet transfusion. The easy adherence between platelets and monocytes even in the absence of an antibody is regarded as one of limitations of the FMPA. To improve the FMPA for prediction of transfusion outcome, we used the pH-sensitive dye pHrodo succinimidyl ester (pHrodo-SE), which has weak fluorescence at neutral pH and has increased fluorescence intensity in low pH conditions such as in lysomes. Platelets stained with pHrodo-SE were sensitized with an HLA class I monoclonal antibody (w6/32 clone) or anti-HLA class I containing antisera. The platelets were incubated with monocyte-enriched mononuclear cells. Phagocytic activity was assessed by the percentage of monocytes that phagocytosed platelets. Sensitization of platelets with w6/32 significantly increased platelet phagocytosis by monocytes in dose- and time-dependent manners. Anti-HLA class I antibody-containing sera caused platelet phagocytosis in a cognate antigen-antibody-dependent manner. There was a significant correlation (r=0.69, p<0.01) between phagocytic index and titer of HLA class I antibody measured by lymphocyte immunofluorescence test-flow cytometry. In addition, the phagocytic index obtained by FMPA with pHrodo-SE was significantly higher than that obtained by FMPA with the previously used dye, carboxyfluorescein diacetate succinimidyl ester, when platelets were sensitized by w6/32 and anti-HLA class I antibody-containing sera. Because of the higher resolution and higher sensitivity than those of the previous method, the pHrodo-SE-based FMPA may be suitable for more precise quantitation of phagocytosis activity, which would enable qualitative evaluation of transfusion effectiveness. Copyright © 2018.

  17. Detection of bacteriophage-infected cells of Lactococcus lactis using flow cytometry

    DEFF Research Database (Denmark)

    Michelsen, Ole; Cuesta-Dominguez, Álvaro; Albrektsen, Bjarne

    2007-01-01

    Bacteriophage infection in dairy fermentation constitutes a serious problem worldwide. We have studied bacteriophage infection in Lactococcus lactis by using the flow cytometer. The first effect of the infection of the bacterium is a change from cells in chains toward single cells. We interpret...... describe a new method for detection of phage infection in Lactococcus lactis dairy cultures. The method is based on flow cytometric detection of cells with low-density cell walls. The method allows fast and early detection of phage-infected bacteria, independently of which phage has infected the culture...

  18. Exploring the feasibility of multi-site flow cytometric processing of gut associated lymphoid tissue with centralized data analysis for multi-site clinical trials.

    Science.gov (United States)

    McGowan, Ian; Anton, Peter A; Elliott, Julie; Cranston, Ross D; Duffill, Kathryn; Althouse, Andrew D; Hawkins, Kevin L; De Rosa, Stephen C

    2015-01-01

    The purpose of this study was to determine whether the development of a standardized approach to the collection of intestinal tissue from healthy volunteers, isolation of gut associated lymphoid tissue mucosal mononuclear cells (MMC), and characterization of mucosal T cell phenotypes by flow cytometry was sufficient to minimize differences in the normative ranges of flow parameters generated at two trial sites. Forty healthy male study participants were enrolled in Pittsburgh and Los Angeles. MMC were isolated from rectal biopsies using the same biopsy acquisition and enzymatic digestion protocols. As an additional comparator, peripheral blood mononuclear cells (PBMC) were collected from the study participants. For quality control, cryopreserved PBMC from a single donor were supplied to both sites from a central repository (qPBMC). Using a jointly optimized standard operating procedure, cells were isolated from tissue and blood and stained with monoclonal antibodies targeted to T cell phenotypic markers. Site-specific flow data were analyzed by an independent center which analyzed all data from both sites. Ranges for frequencies for overall CD4+ and CD8+ T cells, derived from the qPBMC samples, were equivalent at both UCLA and MWRI. However, there were significant differences across sites for the majority of T cell activation and memory subsets in qPBMC as well as PBMC and MMC. Standardized protocols to collect, stain, and analyze MMC and PBMC, including centralized analysis, can reduce but not exclude variability in reporting flow data within multi-site studies. Based on these data, centralized processing, flow cytometry, and analysis of samples may provide more robust data across multi-site studies. Centralized processing requires either shipping of fresh samples or cryopreservation and the decision to perform centralized versus site processing needs to take into account the drawbacks and restrictions associated with each method.

  19. Exploring the feasibility of multi-site flow cytometric processing of gut associated lymphoid tissue with centralized data analysis for multi-site clinical trials.

    Directory of Open Access Journals (Sweden)

    Ian McGowan

    Full Text Available The purpose of this study was to determine whether the development of a standardized approach to the collection of intestinal tissue from healthy volunteers, isolation of gut associated lymphoid tissue mucosal mononuclear cells (MMC, and characterization of mucosal T cell phenotypes by flow cytometry was sufficient to minimize differences in the normative ranges of flow parameters generated at two trial sites. Forty healthy male study participants were enrolled in Pittsburgh and Los Angeles. MMC were isolated from rectal biopsies using the same biopsy acquisition and enzymatic digestion protocols. As an additional comparator, peripheral blood mononuclear cells (PBMC were collected from the study participants. For quality control, cryopreserved PBMC from a single donor were supplied to both sites from a central repository (qPBMC. Using a jointly optimized standard operating procedure, cells were isolated from tissue and blood and stained with monoclonal antibodies targeted to T cell phenotypic markers. Site-specific flow data were analyzed by an independent center which analyzed all data from both sites. Ranges for frequencies for overall CD4+ and CD8+ T cells, derived from the qPBMC samples, were equivalent at both UCLA and MWRI. However, there were significant differences across sites for the majority of T cell activation and memory subsets in qPBMC as well as PBMC and MMC. Standardized protocols to collect, stain, and analyze MMC and PBMC, including centralized analysis, can reduce but not exclude variability in reporting flow data within multi-site studies. Based on these data, centralized processing, flow cytometry, and analysis of samples may provide more robust data across multi-site studies. Centralized processing requires either shipping of fresh samples or cryopreservation and the decision to perform centralized versus site processing needs to take into account the drawbacks and restrictions associated with each method.

  20. Improving the resolution of cryopreserved X- and Y-sperm during DNA flow cytometric analysis with the addition of Percoll to quench the fluorescence of dead sperm

    NARCIS (Netherlands)

    Stap, J.; Hoebe, R. A.; Merton, J. S.; Haring, R. M.; Bakker, P. J.; Aten, J. A.

    1998-01-01

    The most effective method to control the sex of offspring is by separating X- from Y-bearing sperm on the basis of their DNA content. Sperm can be stained with Hoechst 33342 and efficiently sexed using a flow cytometer/cell sorter. However, applying this established assay to cryopreserved bovine

  1. Flow immunocytochemistry of marker expression in cells from body cavity fluids.

    Science.gov (United States)

    Krishan, Awtar; Ganjei-Azar, Parvin; Hamelik, Ronald; Sharma, Deepti; Reis, Isildinha; Nadji, Mehrdad

    2010-02-01

    Diagnostic cytology based on the examination of cells from body cavity fluids misses approximately 50% of patients with a proven malignancy. In an earlier study, we used immunohistochemical detection of epithelial membrane antigen expression with flow cytometric detection of DNA aneuploidy to reduce the number of false negatives. In the present study, we have combined DNA flow cytometry with flow cytometric detection of marker expression to analyze cells from body cavity fluids. Seventy-nine specimens of ascites and pleural fluids were analyzed by diagnostic cytology, DNA flow cytometry, and for the expression of the following markers: Ber-EP4, progesterone (PR), MUC4, and thyroid transcription factor-1 (TTF-1). DNA index of equal to or greater than 1.2 was seen in 33/79 (41.7%) of the samples. Statistical analysis of 79 samples in which data from cytology, DNA aneuploidy, and expression of at least one of the markers was available showed that by combining data from positive marker expression with that of aneuploidy, the sensitivity was increased from 58.5 to 100%. In contrast, out of the 38 samples designated as non-malignant by diagnostic cytology, nine had aneuploid DNA content and 16 of the diploid samples had a positive marker expression. Specificity was reduced from 74.7 to 31.6% due to the presence of aneuploidy and marker expression in these samples. ALDH1(pos)/CD44(pos)/CD24(neg) expression has been reported to be associated with human breast tumor stem cells. Some of our samples had cells with this phenotype. Flow cytometry offers the advantage of rapid multiparametric analysis of DNA aneuploidy and marker expression in cells from body cavity fluids based on the analysis of a large number of cells without observer bias. By further developing the use of specific markers and aneuploidy, it may be possible to refine flow cytometric analysis for rapid detection of malignant cells in body cavity fluids.

  2. Fuel cells flows study

    International Nuclear Information System (INIS)

    Riva, R.; Bador, B.; Marchand, M.; Lebaigue, O.

    1999-01-01

    Fuel cells are energy converters, which directly and continuously produce electricity from paired oxidation reduction-reactions: In most cases, the reactants are oxygen and hydrogen with water as residue. There are several types of fuel cells using various electrolytes and working at different temperatures. Proton Exchange Membrane Fuel Cells are, in particular, studied in the GESTEAU facility. PEMFC performance is chiefly limited by two thermal-hydraulic phenomena: the drying of membranes and the flooding of gas distributors. Up to now, work has been focused on water flooding of gas channels. This has showed the influence of flow type on the electrical behaviour of the cells and the results obtained have led to proposals for new duct geometries. (authors)

  3. Flow cytometry detection of planktonic cells with polycyclic aromatic hydrocarbons sorbed to cell surfaces

    KAUST Repository

    Cerezo, Maria I.

    2017-02-17

    Polycyclic aromatic hydrocarbons are very important components of oil pollution. These pollutants tend to sorb to cell surfaces, exerting toxic effects on organisms. Our study developed a flow cytometric method for the detection of PAHs sorbed to phytoplankton by exploiting their spectral characteristics. We discriminated between cells with PAHs from cells free of PAHs. Clear discrimination was observed with flow cytometer provided with 375 or 405nm lasers in addition to the standard 488nm laser necessary to identify phytoplankton. Using this method, we measured the relationship between the percentages of phytoplankton organisms with PAHs, with the decrease in the growth rate. Moreover, the development of this method could be extended to facilitate the study of PAHs impact on cell cultures from a large variety of organisms.

  4. Cytometric analysis of mammalian sperm for induced morphologic and DNA content errors

    Energy Technology Data Exchange (ETDEWEB)

    Pinkel, D.

    1983-06-27

    Some flow-cytometric and image analysis procedures under development for quantitative analysis of sperm morphology are reviewed. The results of flow-cytometric DNA-content measurements on sperm from radiation exposed mice are also summarized, the results related to the available cytological information, and their potential dosimetric sensitivity discussed. (ACR)

  5. Cytometric analysis of mammalian sperm for induced morphologic and DNA content errors

    International Nuclear Information System (INIS)

    Pinkel, D.

    1983-01-01

    Some flow-cytometric and image analysis procedures under development for quantitative analysis of sperm morphology are reviewed. The results of flow-cytometric DNA-content measurements on sperm from radiation exposed mice are also summarized, the results related to the available cytological information, and their potential dosimetric sensitivity discussed

  6. Lymphocyte subsets show different response patterns to in vivo bound natalizumab--a flow cytometric study on patients with multiple sclerosis.

    Directory of Open Access Journals (Sweden)

    Andrea Harrer

    Full Text Available Natalizumab is an effective monoclonal antibody therapy for the treatment of relapsing-remitting multiple sclerosis (RRMS and interferes with immune cell migration into the central nervous system by blocking the α(4 subunit of very-late activation antigen-4 (VLA-4. Although well tolerated and very effective, some patients still suffer from relapses in spite of natalizumab therapy or from unwanted side effects like progressive multifocal leukoencephalopathy (PML. In search of a routine-qualified biomarker on the effectiveness of natalizumab therapy we applied flow cytometry and analyzed natalizumab binding to α(4 and α(4 integrin surface levels on T-cells, B-cells, natural killer (NK cells, and NKT cells from 26 RRMS patients under up to 72 weeks of therapy. Four-weekly infusions of natalizumab resulted in a significant and sustained increase of lymphocyte-bound natalizumab (p<0.001 which was paralleled by a significant decrease in detectability of the α(4 integrin subunit on all lymphocyte subsets (p<0.001. We observed pronounced natalizumab accumulations on T and B cells at single measurements in all patients who reported clinical disease activity (n = 4. The natalizumab binding capacity of in vitro saturated lymphocytes collected during therapy was strongly diminished compared to treatment-naive cells indicating a therapy-induced reduction of α(4. Summing up, this pilot study shows that flow cytometry is a useful method to monitor natalizumab binding to lymphocytes from RRMS patients under therapy. Investigating natalizumab binding provides an opportunity to evaluate the molecular level of effectiveness of natalizumab therapy in individual patients. In combination with natalizumab saturation experiments, it possibly even provides a means of studying the feasability of patient-tailored infusion intervals. A routine-qualified biomarker on the basis of individual natalizumab saturation on lymphocyte subsets might be an effective tool to

  7. Corrected Lymphocyte Percentages Reduce the Differences in Absolute CD4+ T Lymphocyte Counts between Dual-Platform and Single-Platform Flow Cytometric Approaches.

    Science.gov (United States)

    Noulsri, Egarit; Abudaya, Dinar; Lerdwana, Surada; Pattanapanyasat, Kovit

    2018-03-13

    To determine whether a corrected lymphocyte percentage could reduce bias in the absolute cluster of differentiation (CD)4+ T lymphocyte counts obtained via dual-platform (DP) vs standard single-platform (SP) flow cytometry. The correction factor (CF) for the lymphocyte percentages was calculated at 6 laboratories. The absolute CD4+ T lymphocyte counts in 300 blood specimens infected with human immunodeficiency virus (HIV) were determined using the DP and SP methods. Applying the CFs revealed that 4 sites showed a decrease in the mean bias of absolute CD4+ T lymphocyte counts determined via DP vs standard SP (-109 vs -84 cells/μL, -80 vs -58 cells/μL, -52 vs -45 cells/μL, and -32 vs 1 cells/μL). However, 2 participating laboratories revealed an increase in the difference of the mean bias (-42 vs -49 cells/μL and -20 vs -69 cells/μL). Use of the corrected lymphocyte percentage shows potential for decreasing the difference in CD4 counts between DP and the standard SP method.

  8. Lymphocyte subsets show different response patterns to in vivo bound natalizumab--a flow cytometric study on patients with multiple sclerosis.

    Science.gov (United States)

    Harrer, Andrea; Pilz, Georg; Einhaeupl, Max; Oppermann, Katrin; Hitzl, Wolfgang; Wipfler, Peter; Sellner, Johann; Golaszewski, Stefan; Afazel, Shahrzad; Haschke-Becher, Elisabeth; Trinka, Eugen; Kraus, Joerg

    2012-01-01

    Natalizumab is an effective monoclonal antibody therapy for the treatment of relapsing-remitting multiple sclerosis (RRMS) and interferes with immune cell migration into the central nervous system by blocking the α(4) subunit of very-late activation antigen-4 (VLA-4). Although well tolerated and very effective, some patients still suffer from relapses in spite of natalizumab therapy or from unwanted side effects like progressive multifocal leukoencephalopathy (PML). In search of a routine-qualified biomarker on the effectiveness of natalizumab therapy we applied flow cytometry and analyzed natalizumab binding to α(4) and α(4) integrin surface levels on T-cells, B-cells, natural killer (NK) cells, and NKT cells from 26 RRMS patients under up to 72 weeks of therapy. Four-weekly infusions of natalizumab resulted in a significant and sustained increase of lymphocyte-bound natalizumab (pqualified biomarker on the basis of individual natalizumab saturation on lymphocyte subsets might be an effective tool to improve treatment safety.

  9. Assessment of the viability and fertilizing potential of cryopreserved bovine spermatozoa using dual fluorescent staining and two-flow cytometric systems.

    Science.gov (United States)

    Ericsson, S A; Garner, D L; Redelman, D; Ahmad, K

    1989-04-01

    A dual fluorescent staining system utilizing 5 (and-6)-carboxy-4',5'-dimethyl fluorescein diacetate (CDMFDA) and Hydroethidine (HED) was developed to provide quantifiable information reflective of spermatozoal viability and fertilizing potential. Cryopreserved spermatozoa from ten bulls on which there was fertilizing capacity information were incubated for 1.5, and 3 hr at 39 degrees C prior to fluorogenic staining. Spermatozoa were analyzed using both a FACS Analyzer and an EPICS V flow cytometer to determine if a particular fluorescence pattern was due to an instrumental artifact or cellular processes. Five fluorescent cellular populations were identified by the FACS Analyzer and three populations by the EPICS V. Spermatozoa were quantified after each incubation time for red (HED) and green (CDMFDA) fluorescence. Viable spermatozoa retained the greatest amount of both green and red fluorescence. Dead or moribund spermatozoa had a decrease in over-all fluorescence. The number of viable cells at 0 hr plus the number of dead or morbid cells at any time period were identified by the FACS Analyzer as important in estimating the potential fertility of a bull. The EPICS V identified the number of dead or moribund cells as being related to nonreturn rates. Incubation of samples decreased cellular viability, which resulted in reduced levels of both green and red fluorescence. Similarities between data obtained with both flow cytometers illustrated that cellular processes, not instrumental artifacts, were responsible for the decrease in over-all fluorescence when viability declined, the relationship between the number of cells with specific fluorescence levels and nonreturn rates, and the incubative-induced changes in fluorescence patterns.

  10. Flow Cytometric Determination of Cellular Sources and Frequencies of Key Cytokine-Producing Lymphocytes Directed against Recombinant LACK and Soluble Leishmania Antigen in Human Cutaneous Leishmaniasis

    Science.gov (United States)

    Bottrel, R. L. A.; Dutra, W. O.; Martins, F. A.; Gontijo, B.; Carvalho, E.; Barral-Netto, M.; Barral, A.; Almeida, R. P.; Mayrink, W.; Locksley, R.; Gollob, K. J.

    2001-01-01

    Leishmaniasis, caused by infection with the protozoan parasite Leishmania, affects millions of individuals worldwide, causing serious morbidity and mortality. This study directly determined the frequency of cells producing key immunoregulatory cytokines in response to the recombinant antigen Leishmania homolog of receptors for activated kinase C (LACK) and soluble leishmania antigen (SLA), and it determined relative contributions of these antigens to the overall cytokine profile in individuals infected for the first time with Leishmania braziliensis. All individuals presented with the cutaneous clinical form of leishmaniasis and were analyzed for proliferative responses to LACK antigen and SLA, frequency of lymphocyte subpopulations (analyzed ex vivo), and antigen-induced (LACK and SLA) cytokine production at the single-cell level (determined by flow cytometry). The following were determined. (i) The Th1-type response previously seen in patients with cutaneous leishmaniasis is due to gamma interferon (IFN-γ) production by several different sources, listed in order of contribution: CD4+ T lymphocytes, CD4−, CD8− lymphocytes, and CD8+ T lymphocytes. (ii) SLA induced a higher frequency of lymphocytes producing IFN-γ and tumor necrosis factor alpha (TNF-α) than did LACK. (iii) LACK induced an activation of monocyte populations as reflected by an increased percentage of CD14-positive cells. (iv) Neither SLA nor LACK induced detectable frequencies of cells producing interleukin-4 (IL-4) or IL-5. These data demonstrated a multifaceted immune response to SLA in human leishmaniasis involving Th1 CD4+ T lymphocytes (IFN-γ+ and IL-10−/IL-4−), Tc1 CD8+ T cells (IFN-γ+, and IL-10−/IL-4−), and a high frequency of TNF-α-producing lymphocytes. Moreover, it was determined that the recombinant antigen LACK acts as a weak inducer of Th1-type lymphocyte responses compared to SLA. PMID:11292745

  11. In vitro effects of zirconia and alumina particles on human blood monocyte-derived macrophages: X-ray microanalysis and flow cytometric studies.

    Science.gov (United States)

    Nkamgueu, E M; Adnet, J J; Bernard, J; Zierold, K; Kilian, L; Jallot, E; Benhayoune, H; Bonhomme, P

    2000-12-15

    The cytocompatibility of two particulate bioceramics, zirconia and alumina, was studied using human blood monocytes driven to differentiate into mature macrophages with granulocyte macrophage-colony-stimulating factor. Changes in individual cell elemental composition, particularly sodium and potassium content, were assessed by X-ray microanalysis of ultrathin freeze-dried sections. Phagocytosis and respiratory burst of macrophages exposed to biomaterial for 7 days were analyzed under flow cytometry using uptake of fluorescent latex beads and 2'7'-dichlorofluorescien diacetate oxidation, respectively. Zirconia and alumina particles were found to decrease the intracellular potassium/sodium ratio (an index of cell vitality) significantly (p2 times reduced by zirconia and >5 times reduced by alumina). The present study clearly demonstrates that reduction of the phagocytic capacity of macrophages associated with altered oxidative metabolism caused by biomaterial particles is characterized by changes in intracellular elemental content. Thus, investigation of cellular homeostasis by electron probe microanalysis together with analysis of functional changes may improve estimation of biomaterial cytocompatibility. Copyright 2000 John Wiley & Sons, Inc.

  12. Seasonality in molecular and cytometric diversity of marine bacterioplankton: the reshuffling of bacterial taxa by vertical mixing

    KAUST Repository

    García, Francisca C.

    2015-07-17

    The ’cytometric diversity’ of phytoplankton communities has been studied based on single-cell properties, but the applicability of this method to characterize bacterioplankton has been unexplored. Here, we analysed seasonal changes in cytometric diversity of marine bacterioplankton along a decadal time-series at three coastal stations in the Southern Bay of Biscay. Shannon-Weaver diversity estimates and Bray-Curtis similarities obtained by cytometric and molecular (16S rRNA tag sequencing) methods were significantly correlated in samples from a 3.5-year monthly time-series. Both methods showed a consistent cyclical pattern in the diversity of surface bacterial communities with maximal values in winter. The analysis of the highly resolved flow cytometry time-series across the vertical profile showed that water column mixing was a key factor explaining the seasonal changes in bacterial composition and the winter increase in bacterial diversity in coastal surface waters. Due to its low cost and short processing time as compared to genetic methods, the cytometric diversity approach represents a useful complementary tool in the macroecology of aquatic microbes.

  13. EPR-Spin Trapping and Flow Cytometric Studies of Free Radicals Generated Using Cold Atmospheric Argon Plasma and X-Ray Irradiation in Aqueous Solutions and Intracellular Milieu.

    Science.gov (United States)

    Uchiyama, Hidefumi; Zhao, Qing-Li; Hassan, Mariame Ali; Andocs, Gabor; Nojima, Nobuyuki; Takeda, Keigo; Ishikawa, Kenji; Hori, Masaru; Kondo, Takashi

    2015-01-01

    Electron paramagnetic resonance (EPR)-spin trapping and flow cytometry were used to identify free radicals generated using argon-cold atmospheric plasma (Ar-CAP) in aqueous solutions and intracellularly in comparison with those generated by X-irradiation. Ar-CAP was generated using a high-voltage power supply unit with low-frequency excitation. The characteristics of Ar-CAP were estimated by vacuum UV absorption and emission spectra measurements. Hydroxyl (·OH) radicals and hydrogen (H) atoms in aqueous solutions were identified with the spin traps 5,5-dimethyl-1-pyrroline N-oxide (DMPO), 3,3,5,5-tetramethyl-1-pyrroline-N-oxide (M4PO), and phenyl N-t-butylnitrone (PBN). The occurrence of Ar-CAP-induced pyrolysis was evaluated using the spin trap 3,5-dibromo-4-nitrosobenzene sulfonate (DBNBS) in aqueous solutions of DNA constituents, sodium acetate, and L-alanine. Human lymphoma U937 cells were used to study intracellular oxidative stress using five fluorescent probes with different affinities to a number of reactive species. The analysis and quantification of EPR spectra revealed the formation of enormous amounts of ·OH radicals using Ar-CAP compared with that by X-irradiation. Very small amounts of H atoms were detected whereas nitric oxide was not found. The formation of ·OH radicals depended on the type of rare gas used and the yield correlated inversely with ionization energy in the order of krypton > argon = neon > helium. No pyrolysis radicals were detected in aqueous solutions exposed to Ar-CAP. Intracellularly, ·OH, H2O2, which is the recombination product of ·OH, and OCl- were the most likely formed reactive oxygen species after exposure to Ar-CAP. Intracellularly, there was no practical evidence for the formation of NO whereas very small amounts of superoxides were formed. Despite the superiority of Ar-CAP in forming ·OH radicals, the exposure to X-rays proved more lethal. The mechanism of free radical formation in aqueous solutions and an

  14. EPR-Spin Trapping and Flow Cytometric Studies of Free Radicals Generated Using Cold Atmospheric Argon Plasma and X-Ray Irradiation in Aqueous Solutions and Intracellular Milieu.

    Directory of Open Access Journals (Sweden)

    Hidefumi Uchiyama

    Full Text Available Electron paramagnetic resonance (EPR-spin trapping and flow cytometry were used to identify free radicals generated using argon-cold atmospheric plasma (Ar-CAP in aqueous solutions and intracellularly in comparison with those generated by X-irradiation. Ar-CAP was generated using a high-voltage power supply unit with low-frequency excitation. The characteristics of Ar-CAP were estimated by vacuum UV absorption and emission spectra measurements. Hydroxyl (·OH radicals and hydrogen (H atoms in aqueous solutions were identified with the spin traps 5,5-dimethyl-1-pyrroline N-oxide (DMPO, 3,3,5,5-tetramethyl-1-pyrroline-N-oxide (M4PO, and phenyl N-t-butylnitrone (PBN. The occurrence of Ar-CAP-induced pyrolysis was evaluated using the spin trap 3,5-dibromo-4-nitrosobenzene sulfonate (DBNBS in aqueous solutions of DNA constituents, sodium acetate, and L-alanine. Human lymphoma U937 cells were used to study intracellular oxidative stress using five fluorescent probes with different affinities to a number of reactive species. The analysis and quantification of EPR spectra revealed the formation of enormous amounts of ·OH radicals using Ar-CAP compared with that by X-irradiation. Very small amounts of H atoms were detected whereas nitric oxide was not found. The formation of ·OH radicals depended on the type of rare gas used and the yield correlated inversely with ionization energy in the order of krypton > argon = neon > helium. No pyrolysis radicals were detected in aqueous solutions exposed to Ar-CAP. Intracellularly, ·OH, H2O2, which is the recombination product of ·OH, and OCl- were the most likely formed reactive oxygen species after exposure to Ar-CAP. Intracellularly, there was no practical evidence for the formation of NO whereas very small amounts of superoxides were formed. Despite the superiority of Ar-CAP in forming ·OH radicals, the exposure to X-rays proved more lethal. The mechanism of free radical formation in aqueous solutions and

  15. Measurement of separase proteolytic activity in single living cells by a fluorogenic flow cytometry assay.

    Directory of Open Access Journals (Sweden)

    Wiltrud Haaß

    Full Text Available ESPL1/Separase, an endopeptidase, is required for centrosome duplication and separation of sister-chromatides in anaphase of mitosis. Overexpression and deregulated proteolytic activity of Separase as frequently observed in human cancers is associated with the occurrence of supernumerary centrosomes, chromosomal missegregation and aneuploidy. Recently, we have hypothesized that increased Separase proteolytic activity in a small subpopulation of tumor cells may serve as driver of tumor heterogeneity and clonal evolution in chronic myeloid leukemia (CML. Currently, there is no quantitative assay to measure Separase activity levels in single cells. Therefore, we have designed a flow cytometry-based assay that utilizes a Cy5- and rhodamine 110 (Rh110-biconjugated Rad21 cleavage site peptide ([Cy5-D-R-E-I-M-R]2-Rh110 as smart probe and intracellular substrate for detection of Separase enzyme activity in living cells. As measured by Cy5 fluorescence the cellular uptake of the fluorogenic peptide was fast and reached saturation after 210 min of incubation in human histiocytic lymphoma U937 cells. Separase activity was recorded as the intensity of Rh110 fluorescence released after intracellular peptide cleavage providing a linear signal gain within a 90-180 min time slot. Compared to conventional cell extract-based methods the flow cytometric assay delivers equivalent results but is more reliable, bypasses the problem of vague loading controls and unspecific proteolysis associated with whole cell extracts. Especially suited for the investigaton of blood- and bone marrow-derived hematopoietic cells the flow cytometric Separase assay allows generation of Separase activity profiles that tell about the number of Separase positive cells within a sample i.e. cells that currently progress through mitosis and about the range of intercellular variation in Separase activity levels within a cell population. The assay was used to quantify Separase proteolytic

  16. Flow cytometric readout based on Mitotracker Red CMXRos staining of live asexual blood stage malarial parasites reliably assesses antibody dependent cellular inhibition

    DEFF Research Database (Denmark)

    Jogdand, Prajakta S; Singh, Susheel K; Christiansen, Michael

    2012-01-01

    asynchronous and tightly synchronized asexual blood stage cultures of Plasmodium falciparum were stained with CMXRos and subjected to detection by flow cytometry and fluorescence microscopy. The parasite counts obtained by flow cytometry were compared to standard microscopic counts obtained through examination......ABSTRACT: BACKGROUND: Functional in vitro assays could provide insights into the efficacy of malaria vaccine candidates. For estimating the anti-parasite effect induced by a vaccine candidate, an accurate determination of live parasite count is an essential component of most in vitro bioassays....... Although traditionally parasites are counted microscopically, a faster, more accurate and less subjective method for counting parasites is desirable. In this study mitochondrial dye (Mitotracker Red CMXRos) was used for obtaining reliable live parasite counts through flow cytometry. METHODS: Both...

  17. Challenges of flow-cytometric estimation of nuclear genome size in orchids, a plant group with both whole-genome and progressively partial endoreplication

    Czech Academy of Sciences Publication Activity Database

    Trávníček, Pavel; Ponert, J.; Urfus, Tomáš; Jersáková, Jana; Vrána, Jan; Hřibová, Eva; Doležel, Jaroslav; Suda, Jan

    2015-01-01

    Roč. 87, č. 10 (2015), s. 958-966 ISSN 1552-4922 R&D Projects: GA ČR GAP506/12/1320 Institutional support: RVO:67985939 ; RVO:67179843 ; RVO:61389030 Keywords : flow cytometry * genome size * hyporeduplication Subject RIV: EF - Botanics; EF - Botanics (UEB-Q); EH - Ecology, Behaviour (UEK-B) Impact factor: 3.181, year: 2015

  18. Colour-encoded paramagnetic microbead-based direct inhibition triplex flow cytometric immunoassay for ochratoxin A, fumonisins and zearalenone in cereals and cereal-based feed

    NARCIS (Netherlands)

    Peters, J.; Thomas, D.; Boers, E.A.M.; Rijk, de T.C.; Berthiller, F.; Haasnoot, W.; Nielen, M.W.F.

    2013-01-01

    A combined (triplex) immunoassay for the simultaneous detection of three mycotoxins in grains was developed with superparamagnetic colour-encoded microbeads, in combination with two bead-dedicated flow cytometers. Monoclonal antibodies were coupled to the beads, and the amounts of bound mycotoxins

  19. Flow cytometric readout based on Mitotracker Red CMXRos staining of live asexual blood stage malarial parasites reliably assesses antibody dependent cellular inhibition

    Directory of Open Access Journals (Sweden)

    Jogdand Prajakta S

    2012-07-01

    Full Text Available Abstract Background Functional in vitro assays could provide insights into the efficacy of malaria vaccine candidates. For estimating the anti-parasite effect induced by a vaccine candidate, an accurate determination of live parasite count is an essential component of most in vitro bioassays. Although traditionally parasites are counted microscopically, a faster, more accurate and less subjective method for counting parasites is desirable. In this study mitochondrial dye (Mitotracker Red CMXRos was used for obtaining reliable live parasite counts through flow cytometry. Methods Both asynchronous and tightly synchronized asexual blood stage cultures of Plasmodium falciparum were stained with CMXRos and subjected to detection by flow cytometry and fluorescence microscopy. The parasite counts obtained by flow cytometry were compared to standard microscopic counts obtained through examination of Giemsa-stained thin smears. A comparison of the ability of CMXRos to stain live and compromised parasites (induced by either medium starvation or by anti-malarial drug treatment was carried out. Finally, parasite counts obtained by CMXRos staining through flow cytometry were used to determine specific growth inhibition index (SGI in an antibody-dependent cellular inhibition (ADCI assay. Results Mitotracker Red CMXRos can reliably detect live intra-erythrocytic stages of P. falciparum. Comparison between staining of live with compromised parasites shows that CMXRos predominantly stains live parasites with functional mitochondria. Parasite counts obtained by CMXRos staining and flow cytometry were highly reproducible and can reliably determine the ability of IgG from hyper-immune individuals to inhibit parasite growth in presence of monocytes in ADCI assay. Further, a dose-dependent parasite growth inhibitory effect could be detected for both total IgG purified from hyper-immune sera and affinity purified IgGs against the N-terminal non-repeat region of GLURP

  20. Flow cytometric readout based on Mitotracker Red CMXRos staining of live asexual blood stage malarial parasites reliably assesses antibody dependent cellular inhibition.

    Science.gov (United States)

    Jogdand, Prajakta S; Singh, Susheel K; Christiansen, Michael; Dziegiel, Morten H; Singh, Subhash; Theisen, Michael

    2012-07-20

    Functional in vitro assays could provide insights into the efficacy of malaria vaccine candidates. For estimating the anti-parasite effect induced by a vaccine candidate, an accurate determination of live parasite count is an essential component of most in vitro bioassays. Although traditionally parasites are counted microscopically, a faster, more accurate and less subjective method for counting parasites is desirable. In this study mitochondrial dye (Mitotracker Red CMXRos) was used for obtaining reliable live parasite counts through flow cytometry. Both asynchronous and tightly synchronized asexual blood stage cultures of Plasmodium falciparum were stained with CMXRos and subjected to detection by flow cytometry and fluorescence microscopy. The parasite counts obtained by flow cytometry were compared to standard microscopic counts obtained through examination of Giemsa-stained thin smears. A comparison of the ability of CMXRos to stain live and compromised parasites (induced by either medium starvation or by anti-malarial drug treatment) was carried out. Finally, parasite counts obtained by CMXRos staining through flow cytometry were used to determine specific growth inhibition index (SGI) in an antibody-dependent cellular inhibition (ADCI) assay. Mitotracker Red CMXRos can reliably detect live intra-erythrocytic stages of P. falciparum. Comparison between staining of live with compromised parasites shows that CMXRos predominantly stains live parasites with functional mitochondria. Parasite counts obtained by CMXRos staining and flow cytometry were highly reproducible and can reliably determine the ability of IgG from hyper-immune individuals to inhibit parasite growth in presence of monocytes in ADCI assay. Further, a dose-dependent parasite growth inhibitory effect could be detected for both total IgG purified from hyper-immune sera and affinity purified IgGs against the N-terminal non-repeat region of GLURP in ADCI assays coupled with determination of

  1. Use of flow cytometry for the possible identification of radio-induced changes in DNA of animal cells

    International Nuclear Information System (INIS)

    Spano, M.; Leonardi, M.; Cordelli, E.

    1991-01-01

    Since DNA is the main cellular target of ionizing irradiation, methods fit for analyzing DNA alterations should be able to discern irradiated versus control cells. Flow cytometry allows the rapid measurement of DNA content of single chromosomes or cell nuclei at very high resolution on a statistically significant sample. Alterations of chromatine structure can also be analyzed by flow cytometry. Briefly, evaluation of in situ DNA resistance to denaturation can be evaluated by flow cytometric analysis of different staining pattern of single versus double strange regions of DNA. In the present work both approaches were used with the aim to recognize cells derived from an irradiated sample of breast chicken. Although flow cytometry has been demonstrated to be a useful tool to detect DNA alterations and has been widely used to detect damages on DNA induced by several physical and chemical agents, it was unable to detect clastogenic effects induced by electrons on DNA of chicken breast cells. Heavily irradiated nuclei, even if challenged by denaturating treatments that partially collapse chromatine organization, do not present differences from non irradiated samples after flow cytometric DNA content measurement. (16 refs)

  2. Flow Cytometric DNA index, G-band Karyotyping, and Comparative Genomic Hybridization in Detection of High Hyperdiploidy in Childhood Acute Lymphoblastic Leukemia

    DEFF Research Database (Denmark)

    Nygaard, Ulrikka; Larsen, Jacob; Kristensen, Tim D

    2006-01-01

    High hyperdiploid acute lymphoblastic leukemia in children is related to a good outcome. Because these patients may be stratified to a low-intensity treatment, we have investigated the sensitivity of flow cytometry (FCM), G-band karyotyping (GBK), and high-resolution comparative genomic hybridiza......High hyperdiploid acute lymphoblastic leukemia in children is related to a good outcome. Because these patients may be stratified to a low-intensity treatment, we have investigated the sensitivity of flow cytometry (FCM), G-band karyotyping (GBK), and high-resolution comparative genomic...... hybridization (HR-CGH) in detecting high hyperdiploid leukemic clones. Twenty-six girls and 34 boys with acute lymphoblastic leukemia diagnosed in 1998 to 1999 were analyzed by FCM, GBK, and HR-CGH. The correlations between DNA indices obtained by FCM, GBK, and HR-CGH were significant (rs=0.61 to 0.77; P

  3. In-depth validation of acridine orange staining for flow cytometric parasite and reticulocyte enumeration in an experimental model using Plasmodium berghei

    DEFF Research Database (Denmark)

    Hein-Kristensen, L; Wiese, L; Kurtzhals, J A L

    2009-01-01

    Flow cytometry is potentially an effective method for counting malaria parasites, but inconsistent results have hampered its routine use in rodent models. A published two-channel method using acridine orange offers clear discrimination between the infected and uninfected erythrocytes. However......, preliminary studies showed concerns when dealing with Plasmodium berghei-infected blood samples with high numbers of reticulocytes. In hyperparasitemic or chronic P. berghei infection, enhanced erythropoietic activity results in high numbers of circulating immature reticulocytes. We show that even though...

  4. Detection of HIV-RNA-positive monocytes in peripheral blood of HIV-positive patients by simultaneous flow cytometric analysis of intracellular HIV RNA and cellular immunophenotype.

    Science.gov (United States)

    Patterson, B K; Mosiman, V L; Cantarero, L; Furtado, M; Bhattacharya, M; Goolsby, C

    1998-04-01

    Determinations of plasma HIV viral RNA copy numbers help to define the kinetics of HIV-1 infection in vivo and to monitor antiretroviral therapy. However, questions remain regarding the identity of various infected cell types contributing to this free virus pool and to the in vivo lifecycle of HIV during disease progression. Characterization of a novel fluorescence in situ hybridization (FISH) assay employing a pool of labeled oligonucleotide probes directed against HIV RNA was done followed by coupling of the FISH assay with simultaneous surface immunophenotyping to address these questions. In vitro characterizations of this assay using tumor necrosis factor-alpha stimulated and unstimulated ACH-2 cells demonstrated the ability to detect < 5% HIV RNA positive cells with a sensitivity of < 30 RNA copies per cell. Peripheral blood mononuclear cells from 39 HIV-seropositive patients on no, single, combination, or triple drug therapy and 8 HIV-seronegative patients were examined. The majority of HIV-positive patients (24/39) harbored monocytes positive for HIV RNA and a significantly higher fraction of patients with high plasma viral load carried positive monocytes (13/16) than did patients in the low plasma viral load group (11/23). These results demonstrate the effectiveness of a novel FISH assay for identifying and monitoring HIV-infected cell populations in the peripheral blood of HIV-positive patients. In addition, monocytes are a major source of cellular HIV virus in the peripheral blood of HIV patients, even with progression of disease.

  5. Flow Cytometric DNA index, G-band Karyotyping, and Comparative Genomic Hybridization in Detection of High Hyperdiploidy in Childhood Acute Lymphoblastic Leukemia

    DEFF Research Database (Denmark)

    Nygaard, Ulrikka; Larsen, Jacob; Kristensen, Tim D

    2006-01-01

    High hyperdiploid acute lymphoblastic leukemia in children is related to a good outcome. Because these patients may be stratified to a low-intensity treatment, we have investigated the sensitivity of flow cytometry (FCM), G-band karyotyping (GBK), and high-resolution comparative genomic hybridiza......High hyperdiploid acute lymphoblastic leukemia in children is related to a good outcome. Because these patients may be stratified to a low-intensity treatment, we have investigated the sensitivity of flow cytometry (FCM), G-band karyotyping (GBK), and high-resolution comparative genomic.......001 for all comparisons). However, in 4 of 18 patients, high hyperdiploidy was overlooked by GBK or HR-CGH, and even when FCM was applied, 2 of 18 patients with high hyperdiploidy by GBK and/or HR-CGH were classified as nonhigh hyperdiploid. If high hyperdiploid subclones were included, FCM could detect all...... high hyperdiploid patients found by either GBK or HR-CGH, but would then in addition classify 15% to 20% of the remaining patients as high hyperdiploid. Thus, both GBK and HR-CGH overlook patients with high hyperdiploidy, and FCM only detects all high hyperdiploid patients if small high hyperdiploid...

  6. Generation of highly productive polyclonal and monoclonal tobacco suspension lines from a heterogeneous transgenic BY-2 culture through flow cytometric sorting

    OpenAIRE

    Kirchhoff, Janina

    2012-01-01

    Over the last 20 years, plant cells gained increasing interest as host systems for the production of human and animal pharmaceuticals. Transgenic tobacco suspension cultures are an especially promising production host because of their beneficial growth, low maintenance requirement and the possibility of contained cultivation in bioreactors under controlled conditions. The excellent product quality of plant-produced proteins was demonstrated for a multitude of proteins, but the heterogeneous a...

  7. Innovations in diagnosis and post-therapeutic monitoring of Chagas disease: Simultaneous flow cytometric detection of IgG1 antibodies anti-live amastigote, anti-live trypomastigote, and anti-fixed epimastigote forms of Trypanosoma cruzi.

    Science.gov (United States)

    Alessio, Glaucia Diniz; Côrtes, Denise Fonseca; Machado de Assis, Girley Francisco; Júnior, Policarpo Ademar Sales; Ferro, Eloisa Amália Vieira; Antonelli, Lis Ribeiro do Valle; Teixeira-Carvalho, Andréa; Martins-Filho, Olindo Assis; de Lana, Marta

    2014-11-01

    This study developed a remarkable methodological innovation (FC-ATE) which enables simultaneous detection of antibodies specific to the three evolutive forms of Trypanosoma cruzi: live amastigote (AMA), live trypomastigote (TRYPO), and fixed epimastigote (EPI) using a differential fluorescence staining as low (AMA), intermediate (TRYPO), and high (EPI). An outstanding performance (100%) was observed in the discrimination of the chagasic (CH) and non-chagasic (NCH) patients. In the applicability of FC-ATE in the diagnosis of Chagas disease, 100% of the CH samples presented positivity in the percentage of positive fluorescent parasites (PPFP) for all the three forms of T. cruzi. Moreover, 94% of the samples of NCH presented negative values of PPFP with AMA and TRYPO, and 88% with EPI. Samples from the NCH group with false-positive results were those belonging to the leishmaniasis patients. Considering the applicability of this technique in post-therapeutic monitoring of Chagas disease, 100% of non-treated (NT) and treated non-cured (TNC) samples were positive with the three T. cruzi evolutive forms, while a percentage of 100% from samples of the treated cured (TC) patients were negative with AMA, 93% with TRYPO and 96% with EPI. The comparison between FC-ATE and two other flow cytometric tests using the same samples of patients NT, TNC and TC showed that the three techniques presented different reactivities, although categorical correlation between the methodologies was observed. Taken together, the results obtained with the novel FC-ATE method have shown an outstanding performance in the diagnosis and post-therapeutic monitoring of Chagas disease. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Further evaluation of the prognostic value of morphometric and flow cytometric parameters in breast-cancer patients with long follow-up.

    Science.gov (United States)

    Uyterlinde, A M; Baak, J P; Schipper, N W; Peterse, H; Matze, E; Meijer, C J

    1990-01-15

    The added prognostic value of cellular DNA content compared with single and combined morphometric factors and classical parameters such as tumor size, nodal status, histologic grade and estrogen receptor (ER) content was investigated in 225 consecutive breast-cancer patients with long follow-up. Of all features investigated, the MPI (multivariate prognostic index) had the strongest prognostic value [Mantel-Cox (MC) = 48.2, p less than 0.00005]. The results further showed that neither age nor ER content had significant prognostic value, but the DNA index (DI) as a single parameter had (though weak) prognostic significance (MC = 5.9, p = 0.015); a similar result was obtained with the percentage of S-phase cells (MC = 6.1, p = 0.013). The DI had (restricted) additional prognostic value to the morphometric features (MPI plus DI Mantel-Cox 53.0, p less than 0.0001). The percentage of S-phase cells had no additional prognostic value over the MPI. On the other hand, the additional value of the DI over tumor size and nodal status was much more impressive (MC = 41.0 and 40.7), although it did not reach the prognostic significance of the MPI. Prediction of disease outcome with a linear combination of quantitative microscopical parameters of the primary tumor alone [MAI (mitotic activity index), DI and mean nuclear area] was very accurate, even without considering lymph-node status (MC 30.8, p less than 0.0005). Grade had no additional value to the MPI at all (p = 0.76). This could be especially important for lymph-node-negative patients in whom the prognostic value of the MPI and the MAI are confirmed.

  9. Monitoring functions in managed microbial systems by cytometric bar coding.

    Science.gov (United States)

    Koch, Christin; Fetzer, Ingo; Schmidt, Thomas; Harms, Hauke; Müller, Susann

    2013-02-05

    Cytometric monitoring of microbial community dynamics can be used to estimate stability of technical microbial processes like biogas production by analysis of segregated cell abundance changes. In this study, structure variations of a biogas community were cytometrically recorded over 9 months and found to be of diagnostic value for process details. The reactor regime was intentionally disturbed with regard to substrate overload or H(2)S accumulation. A single-cell based approach called cytometric bar coding (CyBar) for fast identification of reactive subcommunities was used. Functionality of specific subcommunities was uncovered by processing CyBar data with abiotic reactor parameters using Spearman's correlation coefficient. Twenty subcommunities showed a discrete and divergent behavior. For example, a 4-fold substrate overload increased the cell number of two acidogenic index subcommunities to 176 and 193% within three days. Supplementary analyses were done using DNA fingerprinting, cloning, and sequencing. Bioreactor perturbations were shown to create cell abundance changes in subcommunities rather than variations in their phylogenetic composition. The used workflow and macros are ready-to-use tools and allow on-site monitoring and interpretation of variation in microbial community functions within a few hours.

  10. Quantitative analysis of gold and carbon nanoparticles in mammalian cells by flow cytometry light scattering

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Gang [Nanjing University, State Key Laboratory of Pharmaceutical Biotechnology, School of Life Sciences (China); Liu, Naicheng; Wang, Zhenheng [Nanjing University, Department of Orthopedics, Jinling Hospital, School of Medicine (China); Shi, Tongguo; Gan, Jingjing; Wang, Zhenzhen; Zhang, Junfeng, E-mail: jfzhang@nju.edu.cn [Nanjing University, State Key Laboratory of Pharmaceutical Biotechnology, School of Life Sciences (China)

    2017-02-15

    Nanoparticle-based applications for diagnostics and therapeutics have been extensively studied. These applications require a profound understanding of the fate of nanoparticles (NPs) in cellular environments. However, until now, few analytical methods are available and most of them rely on fluorescent properties or special elements of NPs; therefore, for NPs without observable optical properties or special elements, the existing methods are hardly applicable. In this study, we introduce a flow cytometry light scattering (FCLS)-based approach that quantifies in situ NPs accurately in mammalian cells. Continuous cells of heterogeneous human epithelial colorectal adenocarcinoma (Caco-2 cells), mouse peritoneal macrophages (MPM), and human adenocarcinomic alveolar basal epithelia (A549 cells) were cultured with NPs with certain concentrations and size. The intensity of the flow cytometric side scattered light, which indicates the quantity of NPs in the cells, was analyzed. The result shows an accurate size- and dose-dependent uptake of Au NPs (5, 30, 250 nm) in Caco-2 cells. The size- and dose- dependence of Au NPs (5, 30, 250 nm) and carbon NPs (50, 500 nm) in cells was validated by transmission electron microscope (TEM). This paper demonstrates the great potential of flow cytometry light scattering in the quantitative study of the size and dose effect on in situ metallic or non-metallic NPs in mammalian cells.

  11. Cytometric evaluation of intracellular IFN-γ and IL-4 levels in thyroid follicular cells from patients with autoimmune thyroid diseases

    Directory of Open Access Journals (Sweden)

    Bossowski Artur

    2011-09-01

    Full Text Available Abstract Background In recent few years is underlined that altered balance of pro- and anti-inflammatory cytokines play an important role in the pathogenesis of AITD. The aim of this study was to estimate intracellular INF-γ and IL-4 levels in thyroid-infiltrating lymphocytes and thyrocytes isolated from thyroid tissues in 54 adolescent patients aged 8-21 years, with Graves' disease (GD; n = 18, Hashimoto's thyroiditis (HT; n = 18 and non-toxic multinodular goiter (NTMG; n = 18. Methods Fresh thyroid tissues were taken on culture medium RPMI -1640, it was mechanically prepared. In next step were added cell activators -12- myristate 13- the acetate (PMA and Ionomycin as well as the inhibitor of transportation of proteins - Breferdin A. They were cultured 24 hours in 50 ml flasks at 37°C in a 5-95% CO2-air water-saturated atmosphere. After that, thyrocytes were identified by mouse mAb directed against human TPO epitope 64 conjugated with rabbit anti-mouse antibodies IgG (Fab'2 labeled by FITC. After incubation at room temperature to each of samples added reagent A fixative the cellular membrane. In next step into the cell suspensions were added reagent B to permeabilization of cellular membrane and specific anti-IL-4-PE or anti-IFN-γ-PE mAbs. Identification of intracellular cytokines in T lymphocytes was performed in the same procedure with application of anti-CD4-PerCP and anti-CD8-PerCP mAbs specific for T lymphocytes. The cells were analyzed in a flow cytometry (Coulter EPICS XL. Results In examined group of patients with GD we observed statistically significant higher mean percentage of cells with phenotype CD4+IL-4 (p Conclusions We conclude that human thyrocytes in autoimmune thyroid disorders could be a source of cytokine production and that their activation influences local interaction with T lymphocytes inflowing to the thyroid gland.

  12. Fluorescent multiplex cell flow systems and methods

    KAUST Repository

    Merzaban, Jasmeen

    2017-06-01

    Systems and methods are provided for simultaneously assaying cell adhesion or cell rolling for multiple cell specimens. One embodiment provides a system for assaying adhesion or cell rolling of multiple cell specimens that includes a confocal imaging system containing a parallel plate flow chamber, a pump in fluid communication with the parallel plate flow chamber via a flow chamber inlet line and a cell suspension in fluid communication with the parallel plate flow chamber via a flow chamber outlet line. The system also includes a laser scanning system in electronic communication with the confocal imaging system, and a computer in communication with the confocal imaging system and laser scanning system. In certain embodiments, the laser scanning system emits multiple electromagnetic wavelengths simultaneously it cause multiple fluorescent labels having different excitation wavelength maximums to fluoresce. The system can simultaneously capture real-time fluorescence images from at least seven cell specimens in the parallel plate flow chamber.

  13. Challenges of setting up flow cytometry for diagnosis of leukemia ...

    African Journals Online (AJOL)

    The bone marrow (BM) is a complex tissue containing cells of multiple hematopoietic cell lineages in all stages of development. Flow cytometric immunophenotyping evaluates the frequencies of the various leukocyte (sub) populations in BM and blood that then helps in the diagnosis of leukemia's. The aim of this study was ...

  14. Flow Cell Design for Effective Biosensing

    Science.gov (United States)

    Pike, Douglas J.; Kapur, Nikil; Millner, Paul A.; Stewart, Douglas I.

    2013-01-01

    The efficiency of three different biosensor flow cells is reported. All three flow cells featured a central channel that expands in the vicinity of the sensing element to provide the same diameter active region, but the rate of channel expansion and contraction varied between the designs. For each cell the rate at which the analyte concentration in the sensor chamber responds to a change in the influent analyte concentration was determined numerically using a finite element model and experimentally using a flow-fluorescence technique. Reduced flow cell efficiency with increasing flow rates was observed for all three designs and was related to the increased importance of diffusion relative to advection, with efficiency being limited by the development of regions of recirculating flow (eddies). However, the onset of eddy development occurred at higher flow rates for the design with the most gradual channel expansion, producing a considerably more efficient flow cell across the range of flow rates considered in this study. It is recommended that biosensor flow cells be designed to minimize the tendency towards, and be operated under conditions that prevent the development of flow recirculation. PMID:23344373

  15. Fuel cell with internal flow control

    Science.gov (United States)

    Haltiner, Jr., Karl J.; Venkiteswaran, Arun [Karnataka, IN

    2012-06-12

    A fuel cell stack is provided with a plurality of fuel cell cassettes where each fuel cell cassette has a fuel cell with an anode and cathode. The fuel cell stack includes an anode supply chimney for supplying fuel to the anode of each fuel cell cassette, an anode return chimney for removing anode exhaust from the anode of each fuel cell cassette, a cathode supply chimney for supplying oxidant to the cathode of each fuel cell cassette, and a cathode return chimney for removing cathode exhaust from the cathode of each fuel cell cassette. A first fuel cell cassette includes a flow control member disposed between the anode supply chimney and the anode return chimney or between the cathode supply chimney and the cathode return chimney such that the flow control member provides a flow restriction different from at least one other fuel cell cassettes.

  16. Responses of Cells to Flow in Vitro

    Directory of Open Access Journals (Sweden)

    Shigehiro Hashimoto

    2013-06-01

    Full Text Available The response of cells to a flow has been studied in vitro. The response of cells was examined in two types of flow channels: a circumnutating flow in a donut-shaped open channel in a culture dish, and a one-way flow in a parallelepiped rhombus flow channel. Variation was made on the material of the parallelepiped channel to study on adhesion of cells to the plates: glass and polydimethylsiloxane. Behavior of cells on the plate was observed under a flow of a medium with an inverted phase-contrast-microscope. The shear stress on the plate is calculated with an estimated parabolic distribution of the velocity between the parallel plates. The adhesion of cells was evaluated with the cumulated shear, which is a product of the shear stress and the exposure time. The experimental results show that cells are responsive to the flow, which governs orientation, exfoliation, and differentiation. The response depends on the kinds of cells: endothelial cells orient along the stream line, although myocytes orient perpendicular to the stream line. The adhesion depends on the combination between scaffold and cell: myocytes are more adhesive to glass than cartilage cells, and fibroblasts are more adhesive to oxygenated polydimethylsiloxane than glass.

  17. Multiplex flow cytometry barcoding and antibody arrays identify surface antigen profiles of primary and metastatic colon cancer cell lines.

    Directory of Open Access Journals (Sweden)

    Kumar Sukhdeo

    Full Text Available Colon cancer is a deadly disease affecting millions of people worldwide. Current treatment challenges include management of disease burden as well as improvements in detection and targeting of tumor cells. To identify disease state-specific surface antigen signatures, we combined fluorescent cell barcoding with high-throughput flow cytometric profiling of primary and metastatic colon cancer lines (SW480, SW620, and HCT116. Our multiplexed technique offers improvements over conventional methods by permitting the simultaneous and rapid screening of cancer cells with reduced effort and cost. The method uses a protein-level analysis with commercially available antibodies on live cells with intact epitopes to detect potential tumor-specific targets that can be further investigated for their clinical utility. Multiplexed antibody arrays can easily be applied to other tumor types or pathologies for discovery-based approaches to target identification.

  18. Identification and detection of murine leukemia blasts by flow cytometry

    OpenAIRE

    sprotocols

    2015-01-01

    Human leukemia has been determined and classified with the help of flow cytometry for the past two decades. Past attempts to detect leukemia blasts relied on both forward and side scatter (FSC and SSC) based on cell size and granularity. However, this technique failed to show a clean separation of blasts from normal lineage cells. In 1993, Borowitz, et al developed flow cytometric analysis to distinguish human leukemia blasts from other normal lineage cells by using fluorescence-conjugated CD...

  19. A selective procedure for DNA extraction from apoptotic cells applicable for gel electrophoresis and flow cytometry.

    Science.gov (United States)

    Gong, J; Traganos, F; Darzynkiewicz, Z

    1994-05-01

    In cells undergoing apoptosis (programmed cell death), a fraction of nuclear DNA is fragmented to the size equivalent of DNA in mono- or oligonucleosomes. When such DNA is analyzed by agarose gel electrophoresis it generates the characteristic "ladder" pattern of discontinuous DNA fragments. Such a pattern of DNA degradation generally serves as a marker of the apoptotic mode of cell death. We developed a simple, rapid, and selective procedure for extraction of the degraded, low-molecular-weight DNA from apoptotic cells. The cells are prefixed in 70% ethanol, DNA is extracted with 0.2 M phosphate-citrate buffer at pH 7.8, and the extract is sequentially treated with RNase A and proteinase K and then subjected to electrophoresis. The ladder pattern was detected from DNA extracted from 1-2 x 10(6) HL-60 cells, of which as few as 8% were apoptotic, by flow cytometric criteria, as well as from blood and bone marrow samples from leukemic patients undergoing chemotherapy. The method is rapid and uses nontoxic reagents (no phenol, chloroform, etc.). This approach permits the analysis of DNA extracted from the very same cell population that is subjected to measurements by flow cytometry to estimate DNA ploidy, the cell cycle distribution of nonapoptotic cells, the percentage of apoptotic cells, or other parameters. Furthermore, the cells may be stored in 70% ethanol for at least several weeks before analysis without any significant DNA degradation. Treatment with ethanol also inactivates several pathogens, thereby increasing the safety of sample handling. The method is applicable to clinical samples, which can be fixed in ethanol and then stored and/or safety transported prior to analysis.

  20. The CD8+ granzyme B+ T-cell subset in peripheral blood from healthy individuals contains activated and apoptosis-prone cells

    NARCIS (Netherlands)

    Wever, P. C.; van der Vliet, H. J.; Spaeny, L. H.; Wolbink, A. M.; van Diepen, F. N.; Froelich, C. J.; Hack, C. E.; ten Berge, I. J.

    1998-01-01

    Granzyme B (GrB) has been implicated in induction of apoptosis in target cells. The presence of GrB in peripheral blood CD8+ T cells from healthy individuals was analysed in immunocytochemical and flow cytometric studies. Furthermore, CD8+ GrB- T cells and CD8+ GrB+ T cells were compared regarding

  1. Geophysical Fluid Flow Cell (GFFC) Simulation

    Science.gov (United States)

    1999-01-01

    These simulations of atmospheric flow use the same experimental parameters but started with slightly different initial conditions in the model. The simulations were part of data analysis for the Geophysical Fluid Flow Cell (GFFC), a planet in a test tube apparatus flown on Spacelab to mimic the atmospheres on gas giant planets and stars. (Credit: Dr. Tim Miller of Global Hydrology and Climate Center at the Marshall Space Flight Center)

  2. Detection of Xanthomonas axonopodis pv. phaseoli in bean seeds by flow cytometry, immunostaining and direct viable counting

    NARCIS (Netherlands)

    Tebaldi, N.D.; Peters, J.; Chitarra, L.G.; Souza, R.M.; Zouwen, van der P.S.; Bergervoet, J.H.W.; Wolf, van der J.M.

    2010-01-01

    Flow cytometric analysis of immuno-stained cells (immuno-FCM) was compared to immunofluorescence microscopy (IF) and dilution plating on a semi-selective medium, for quantitative detection of Xanthomonas axonopodis pv. phaseoli (Xap) in bean seed extracts. Cell concentrations of Xap between 103-107

  3. FLOCK cluster analysis of mast cell event clustering by high-sensitivity flow cytometry predicts systemic mastocytosis.

    Science.gov (United States)

    Dorfman, David M; LaPlante, Charlotte D; Pozdnyakova, Olga; Li, Betty

    2015-11-01

    In our high-sensitivity flow cytometric approach for systemic mastocytosis (SM), we identified mast cell event clustering as a new diagnostic criterion for the disease. To objectively characterize mast cell gated event distributions, we performed cluster analysis using FLOCK, a computational approach to identify cell subsets in multidimensional flow cytometry data in an unbiased, automated fashion. FLOCK identified discrete mast cell populations in most cases of SM (56/75 [75%]) but only a minority of non-SM cases (17/124 [14%]). FLOCK-identified mast cell populations accounted for 2.46% of total cells on average in SM cases and 0.09% of total cells on average in non-SM cases (P < .0001) and were predictive of SM, with a sensitivity of 75%, a specificity of 86%, a positive predictive value of 76%, and a negative predictive value of 85%. FLOCK analysis provides useful diagnostic information for evaluating patients with suspected SM, and may be useful for the analysis of other hematopoietic neoplasms. Copyright© by the American Society for Clinical Pathology.

  4. Evaluation of CD307a expression patterns during normal B-cell maturation and in B-cell malignancies by flow cytometry.

    Science.gov (United States)

    Auat, Mariangeles; Cardoso, Chandra Chiappin; Santos-Pirath, Iris Mattos; Rudolf-Oliveira, Renata Cristina Messores; Matiollo, Camila; Lange, Bárbara Gil; da Silva, Jessica Pires; Dametto, Gisele Cristina; Pirolli, Mayara Marin; Colombo, Maria Daniela Holthausen Perico; Santos-Silva, Maria Claudia

    2018-02-24

    Flow cytometric immunophenotyping is deemed a fundamental tool for the diagnosis of B-cell neoplasms. Currently, the investigation of novel immunophenotypic markers has gained importance, as they can assist in the precise subclassification of B-cell malignancies by flow cytometry. Therefore, the purpose of the present study was to evaluate the expression of CD307a during normal B-cell maturation and in B-cell malignancies as well as to investigate its potential role in the differential diagnosis of these entities. CD307a expression was assessed by flow cytometry in normal precursor and mature B cells and in 115 samples collected from patients diagnosed with precursor and mature B-cell neoplasms. CD307a expression was compared between neoplastic and normal B cells. B-acute lymphoblastic leukemia cases exhibited minimal expression of CD307a, displaying a similar expression pattern to that of normal B-cell precursors. Mantle cell lymphoma (MCL) cases showed the lowest levels of CD307a among mature B-cell neoplasms. CD307a expression was statistically lower in MCL cases than in chronic B lymphocytic leukemia (CLL) and marginal zone lymphoma (MZL) cases. No statistical differences were observed between CD307a expression in neoplastic and normal plasma cells. These results indicate that the assessment of CD307a expression by flow cytometry could be helpful to distinguish CLL from MCL, and the latter from MZL. Although these results are not entirely conclusive, they provide a basis for further studies in a larger cohort of patients. © 2018 International Clinical Cytometry Society. © 2018 International Clinical Cytometry Society.

  5. Cell and nuclear enlargement of SW480 cells induced by a plant lignan, arctigenin: evaluation of cellular DNA content using fluorescence microscopy and flow cytometry.

    Science.gov (United States)

    Kang, Kyungsu; Lee, Hee Ju; Yoo, Ji-Hye; Jho, Eun Hye; Kim, Chul Young; Kim, Minkyun; Nho, Chu Won

    2011-08-01

    Arctigenin is a natural plant lignan previously shown to induce G(2)/M arrest in SW480 human colon cancer cells as well as AGS human gastric cancer cells, suggesting its use as a possible cancer chemopreventive agent. Changes in cell and nuclear size often correlate with the functionality of cancer-treating agents. Here, we report that arctigenin induces cell and nuclear enlargement of SW480 cells. Arctigenin clearly induced the formation of giant nuclear shapes in SW480, as demonstrated by fluorescence microscopic observation and quantitative determination of nuclear size. Cell and nuclear size were further assessed by flow cytometric analysis of light scattering and fluorescence pulse width after propidium iodide staining. FSC-H and FL2-W values (parameters referring to cell and nuclear size, respectively) significantly increased after arctigenin treatment; the mean values of FSC-H and FL2-W in arctigenin-treated SW480 cells were 572.6 and 275.1, respectively, whereas those of control cells were 482.0 and 220.7, respectively. Our approach may provide insights into the mechanism behind phytochemical-induced cell and nuclear enlargement as well as functional studies on cancer-treating agents.

  6. Towards optical cell transfection inside a micro flow cell

    Science.gov (United States)

    Breunig, H. G.; Uchugonova, A.; König, K.

    2014-03-01

    For optical transfection, cells are shortly subjected to intense, focused laser radiation which leads to a temporary opening in the cell membrane. Although the method is very efficient and ensures high cell viability, the targeting of single cells with laser pulses is a tedious and slow approach. We present first measurements aiming at an experimental setup which is suitable for high throughput and automated optical cell transfection. In our setup, cells flow through a micro flow cell where they are spatially confined. The laser radiation is focused into the cell in a way that an elongated focal region is realized. This makes the time consuming aiming of the laser beam at individual cells unnecessary and opens the possibility to develop a completely automated system. The elongated laser focal region is realized by a quasi-Bessel beam which is generated by an axicon lens setup and continuously scanned from side to side of the cell. We present test measurements of the newly employed setup and discuss its suitability to be fully integrated into a flow cell sequencing system.

  7. Flow-Based Single Cell Deposition for High-Throughput Screening of Protein Libraries.

    Directory of Open Access Journals (Sweden)

    Cassandra Stowe

    Full Text Available The identification and engineering of proteins having refined or novel characteristics is an important area of research in many scientific fields. Protein modelling has enabled the rational design of unique proteins, but high-throughput screening of large libraries is still required to identify proteins with potentially valuable properties. Here we report on the development and evaluation of a novel fluorescent activated cell sorting based screening platform. Single bacterial cells, expressing a protein library to be screened, are electronically sorted and deposited onto plates containing solid nutrient growth media in a dense matrix format of between 44 and 195 colonies/cm2. We show that this matrix format is readily applicable to machine interrogation (<30 seconds per plate and subsequent bioinformatic analysis (~60 seconds per plate thus enabling the high-throughput screening of the protein library. We evaluate this platform and show that bacteria containing a bioluminescent protein can be spectrally analysed using an optical imager, and a rare clone (0.5% population can successfully be identified, picked and further characterised. To further enhance this screening platform, we have developed a prototype electronic sort stream multiplexer, that when integrated into a commercial flow cytometric sorter, increases the rate of colony deposition by 89.2% to 24 colonies per second. We believe that the screening platform described here is potentially the foundation of a new generation of high-throughput screening technologies for proteins.

  8. Multiparameter cytometric analysis of complex cellular response

    Czech Academy of Sciences Publication Activity Database

    Šimečková, Šárka; Fedr, Radek; Remšík, Jan; Kahounová, Z.; Slabáková, Eva; Souček, Karel

    2018-01-01

    Roč. 93A, č. 2 (2018), s. 239-248 ISSN 1552-4922 R&D Projects: GA MZd(CZ) NV15-28628A; GA MZd(CZ) NV15-33999A; GA MZd(CZ) NV17-28518A Institutional support: RVO:68081707 Keywords : flow-cytometry * permeabilization * apoptosis * fixation Subject RIV: EB - Genetics ; Molecular Biology OBOR OECD: Cell biology Impact factor: 3.222, year: 2016

  9. Multiparameter cytometric analysis of complex cellular response.

    Science.gov (United States)

    Šimečková, Šárka; Fedr, Radek; Remšík, Ján; Kahounová, Zuzana; Slabáková, Eva; Souček, Karel

    2018-02-01

    Complex analysis of cellular responses after experimental treatment is important for screening, mechanistic understanding of treatment effects, and the identification of sensitive and resistant cell phenotypes. Modern multicolor flow cytometry has demonstrated its power for such analyses. Here, we introduce a multiparametric protocol for complex analysis of cytokinetics by the simultaneous detection of seven fluorescence parameters. This analysis includes the detection of two surface markers for immunophenotyping, analysis of proliferation based on the cell cycle and the measurement of incorporated nucleoside analogue 5-ethynyl-2'-deoxyuridine (EdU) in newly synthesized DNA, analysis of DNA damage using an anti-phospho-histone H2A.X (Ser139) antibody, and determination of cell death using a fixable viability probe and intracellular detection of caspase-3 activation. To demonstrate the applicability of this protocol for the analysis of heterogeneous and complex cell responses, we used different treatments and model cell lines. We demonstrated that this protocol has the potential to provide complex and simultaneous analysis of cytokinetics and analyze the heterogeneity of the response at the single-cell level. © 2017 International Society for Advancement of Cytometry. © 2017 International Society for Advancement of Cytometry.

  10. A Triple-Stain Flow Cytometric Method to Assess Plasma- and Acrosome-Membrane Integrity of Cryopreserved Bovine Sperm Immediately after Thawing in Presence of Egg-Yolk Particles

    NARCIS (Netherlands)

    Nagy, S.; Jansen, J.; Topper, E.K.; Gadella, B.M.

    2003-01-01

    Simultaneously evaluating postthaw viability and acrosome integrity of spermatozoa by flow cytometry would provide a valuable testing tool in both research and routine work. In the present study, a new triple-stain combination was developed for the simultaneous evaluation of viability and acrosome

  11. Effect on growth and cell cycle kinetics of estradiol and tamoxifen on MCF-7 human breast cancer cells grown in vitro and in nude mice

    DEFF Research Database (Denmark)

    Brünner, N; Bronzert, D; Vindeløv, L L

    1989-01-01

    determined by repeated flow cytometric DNA analyses in vitro and in vivo and by the technique of labeled mitosis in nude mouse-grown tumors. Under in vitro conditions, estradiol induced a pronounced increase in S-phase fraction and cell number. TAM inhibited growth of MCF-7 cells with a concomitant increase...

  12. Image cytometric nuclear texture features in inoperable head and neck cancer: a pilot study

    International Nuclear Information System (INIS)

    Strojan-Flezar, Margareta; Lavrencak, Jaka; Zganec, Mario; Strojan, Primoz

    2011-01-01

    Image cytometry can measure numerous nuclear features which could be considered a surrogate end-point marker of molecular genetic changes in a nucleus. The aim of the study was to analyze image cytometric nuclear features in paired samples of primary tumor and neck metastasis in patients with inoperable carcinoma of the head and neck. Image cytometric analysis of cell suspensions prepared from primary tumor tissue and fine needle aspiration biopsy cell samples of neck metastases from 21 patients treated with concomitant radiochemotherapy was performed. Nuclear features were correlated with clinical characteristics and response to therapy. Manifestation of distant metastases and new primaries was associated (p<0.05) with several chromatin characteristics from primary tumor cells, whereas the origin of index cancer and disease response in the neck was related to those in the cells from metastases. Many nuclear features of primary tumors and metastases correlated with the TNM stage. A specific pattern of correlation between well-established prognostic indicators and nuclear features of samples from primary tumors and those from neck metastases was observed. Image cytometric nuclear features represent a promising candidate marker for recognition of biologically different tumor subgroups

  13. Dose-dependent effect of 17 beta-estradiol determined by growth curves and flow cytometric DNA analysis of a human breast carcinoma (T61) grown in nude mice

    DEFF Research Database (Denmark)

    Brünner, N; Spang-Thomsen, M; Vindeløv, L

    1985-01-01

    An estrogen and progesterone receptor-positive human breast carcinoma (T61) grown in nude mice was exposed to 1.0, 0.1, 0.01, and 0.001 mg 17 beta-estradiol. These doses resulted in serum peak concentrations (day 1) of estradiol ranging from 3.5 X 10(-8) to 6.9 X 10(-10) M. The effect...... fraction of polyploid cells. The results suggest that estradiol induces a dose-dependent cell killing effect in the T61 human breast carcinoma. The correlation between the treatment-induced growth delay and the effect on the cell cycle distribution indicates that the changes in the cell cycle...... are a reflection of the estradiol-induced cell destruction. Since no tumor growth stimulation could be observed even at very low serum estradiol concentrations, the T61 human breast carcinoma may represent a new aspect in the study of human breast cancer....

  14. Lawsone inhibits cell growth and improves the efficacy of cisplatin in ...

    African Journals Online (AJOL)

    Cell cycle analysis was done by Flow cytometric studies, Immunoblotting studies for protein expression was done, proteins controlling cell cycle such as cyclinD1, cyclin E, cyclin A, cyclin B1 and Cip1/p21 and p53 which also are cyclin dependent inhibitors of protein kinase were estimated. Annexin V staining was done to ...

  15. Red blood cell in simple shear flow

    Science.gov (United States)

    Chien, Wei; Hew, Yayu; Chen, Yeng-Long

    2013-03-01

    The dynamics of red blood cells (RBC) in blood flow is critical for oxygen transport, and it also influences inflammation (white blood cells), thrombosis (platelets), and circulatory tumor migration. The physical properties of a RBC can be captured by modeling RBC as lipid membrane linked to a cytoskeletal spectrin network that encapsulates cytoplasm rich in hemoglobin, with bi-concave equilibrium shape. Depending on the shear force, RBC elasticity, membrane viscosity, and cytoplasm viscosity, RBC can undergo tumbling, tank-treading, or oscillatory motion. We investigate the dynamic state diagram of RBC in shear and pressure-driven flow using a combined immersed boundary-lattice Boltzmann method with a multi-scale RBC model that accurately captures the experimentally established RBC force-deformation relation. It is found that the tumbling (TU) to tank-treading (TT) transition occurs as shear rate increases for cytoplasm/outer fluid viscosity ratio smaller than 0.67. The TU frequency is found to be half of the TT frequency, in agreement with experiment observations. Larger viscosity ratios lead to the disappearance of stable TT phase and unstable complex dynamics, including the oscillation of the symmetry axis of the bi-concave shape perpendicular to the flow direction. The dependence on RBC bending rigidity, shear modulus, the order of membrane spectrin network and fluid field in the unstable region will also be discussed.

  16. Sex-sorting sperm using flow cytometry/cell sorting.

    Science.gov (United States)

    Garner, Duane L; Evans, K Michael; Seidel, George E

    2013-01-01

    The sex of mammalian offspring can be predetermined by flow sorting relatively pure living populations of X- and Y-chromosome-bearing sperm. This method is based on precise staining of the DNA of sperm with the nucleic acid-specific fluorophore, Hoechst 33342, to differentiate between the subpopulations of X- and Y-sperm. The fluorescently stained sperm are then sex-sorted using a specialized high speed sorter, MoFlo(®) SX XDP, and collected into biologically supportive media prior to reconcentration and cryopreservation in numbers adequate for use with artificial insemination for some species or for in vitro fertilization. Sperm sorting can provide subpopulations of X- or Y-bearing bovine sperm at rates in the 8,000 sperm/s range while maintaining; a purity of 90% such that it has been applied to cattle on a commercial basis. The sex of offspring has been predetermined in a wide variety of mammalian species including cattle, swine, horses, sheep, goats, dogs, cats, deer, elk, dolphins, water buffalo as well as in humans using flow cytometric sorting of X- and Y-sperm.

  17. Plant cytokinin analogues with inhibitory activity on cyclin-dependent kinases exert their antiproliferative effect through induction of apoptosis initiated by the mitochondrial pathway: Determination by a multiparametric flow cytometric analysis

    Czech Academy of Sciences Publication Activity Database

    Vermeulen, K.; Strnad, Miroslav; Havlíček, Libor; Onckelen, H.; Lenjou, M.; Nijs, G.; Bockstaele, D. R.; Berneman, Z. N.

    2002-01-01

    Roč. 30, č. 10 (2002), s. 1107-1114 ISSN 0301-472X R&D Projects: GA MŠk OC 844.10 Institutional research plan: CEZ:AV0Z5038910 Keywords : PLASMA MEMBRANE * PURINE ANALOGS * CELLS Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 3.366, year: 2002

  18. Redox flow cell energy storage systems

    Science.gov (United States)

    Thaller, L. H.

    1979-01-01

    NASA-Redox systems are electrochemical storage devices that use two fully soluble Redox couples, anode and cathode fluids, as active electrode materials separated by a highly selective ion exchange membrane. The reactants are contained in large storage tanks and pumped through a stack of Redox flow cells where the electrochemical reactions (reduction and oxidation) take place at porous carbon felt electrodes. A string or stack of these power producing cells is connected in series in a bipolar manner. Redox energy storage systems promise to be inexpensive and possess many features that provide for flexible design, long life, high reliability and minimal operation and maintenance costs. These features include independent sizing of power and storage capacity requirements and inclusion within the cell stack of a cell that monitors the state of charge of the system as a whole, and a rebalance cell which permits continuous correction to be made for minor side reactions that would tend to result in the anode fluid and cathode fluids becoming electrochemically out of balance. These system features are described and discussed.

  19. Intestinal intraepithelial lymphocyte cytometric pattern is more accurate than subepithelial deposits of anti-tissue transglutaminase IgA for the diagnosis of celiac disease in lymphocytic enteritis.

    Directory of Open Access Journals (Sweden)

    Fernando Fernández-Bañares

    Full Text Available BACKGROUND & AIMS: An increase in CD3+TCRγδ+ and a decrease in CD3- intraepithelial lymphocytes (IEL is a characteristic flow cytometric pattern of celiac disease (CD with atrophy. The aim was to evaluate the usefulness of both CD IEL cytometric pattern and anti-TG2 IgA subepithelial deposit analysis (CD IF pattern for diagnosing lymphocytic enteritis due to CD. METHODS: Two-hundred and five patients (144 females who underwent duodenal biopsy for clinical suspicion of CD and positive celiac genetics were prospectively included. Fifty had villous atrophy, 70 lymphocytic enteritis, and 85 normal histology. Eight patients with non-celiac atrophy and 15 with lymphocytic enteritis secondary to Helicobacter pylori acted as control group. Duodenal biopsies were obtained to assess both CD IEL flow cytometric (complete or incomplete and IF patterns. RESULTS: Sensitivity of IF, and complete and incomplete cytometric patterns for CD diagnosis in patients with positive serology (Marsh 1+3 was 92%, 85 and 97% respectively, but only the complete cytometric pattern had 100% specificity. Twelve seropositive and 8 seronegative Marsh 1 patients had a CD diagnosis at inclusion or after gluten free-diet, respectively. CD cytometric pattern showed a better diagnostic performance than both IF pattern and serology for CD diagnosis in lymphocytic enteritis at baseline (95% vs 60% vs 60%, p = 0.039. CONCLUSIONS: Analysis of the IEL flow cytometric pattern is a fast, accurate method for identifying CD in the initial diagnostic biopsy of patients presenting with lymphocytic enteritis, even in seronegative patients, and seems to be better than anti-TG2 intestinal deposits.

  20. Method of detaching adherent cells for flow cytometry

    KAUST Repository

    Kaur, Mandeep

    2015-12-24

    In one aspect, a method for detaching adherent cells can include adding a cell lifting solution to the media including a sample of adherent cells and incubating the sample of adherent cells with the cell lifting solution. No scraping or pipetting is needed to facilitate cell detachment. The method do not require inactivation of cell lifting solution and no washing of detaching cells is required to remove cell lifting solution. Detached cells can be stained with dye in the presence of cell lifting solution and are further analyzed using flow cytometer. The method has been tested using 6 different cell lines, 4 different assays, two different plate formats (96 and 384 well plates) and two different flow cytometry instruments. The method is simple to perform, less time consuming, with no cell loss and makes high throughput flow cytometry on adherent cells a reality.

  1. Flow Cells for Scalable Energy Conversion and Storage

    Energy Technology Data Exchange (ETDEWEB)

    Mukundan, Rangachary [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-10-26

    This project is a response to current flow systems that are V-aqueous and not cost effective. It will hopefully enable high energy/ power density flow cells through rational materials and system design.

  2. Expression of Cyclins A, E and Topoisomerase II α correlates with centrosome amplification and genomic instability and influences the reliability of cytometric S-phase determination

    Directory of Open Access Journals (Sweden)

    Laytragoon-Lewin Nongnit

    2003-07-01

    Full Text Available Abstract Background The progression of normal cells through the cell cycle is meticulously regulated by checkpoints guaranteeing the exact replication of the genome during S-phase and its equal division at mitosis. A prerequisite for this achievement is synchronized DNA-replication and centrosome duplication. In this context the expression of cyclins A and E has been shown to play a principal role. Results Our results demonstrated a correlation between centrosome amplification, cell cycle fidelity and the level of mRNA and protein expression of cyclins A and E during the part of the cell cycle defined as G1-phase by means of DNA content based histogram analysis. It is shown that the normal diploid breast cell line HTB-125, the genomically relatively stable aneuploid breast cancer cell line MCF-7, and the genomically unstable aneuploid breast cancer cell line MDA-231 differ remarkably concerning both mRNA and protein expression of the two cyclins during G1-phase. In MDA-231 cells the expression of e.g. cyclin A mRNA was found to be ten times higher than in MCF-7 cells and about 500 times higher than in HTB-125 cells. Topoisomerase II α showed high mRNA expression in MDA compared to MCF-7 cells, but the difference in protein expression was small. Furthermore, we measured centrosome aberrations in 8.4% of the MDA-231 cells, and in only 1.3% of the more stable aneuploid cell line MCF-7. MDA cells showed 27% more incorporation of BrdU than reflected by S-phase determination with flow cytometric DNA content analysis, whereas these values were found to be of the same size in both HTB-125 and MCF-7 cells. Conclusions Our data indicate that the breast cancer cell lines MCF-7 and MDA-231, although both DNA-aneuploid, differ significantly regarding the degree of cell cycle disturbance and centrosome aberrations, which partly could explain the different genomic stability of the two cell lines. The results also question the reliability of cytometric DNA

  3. Flow Cytometry Detection of Bacterial Cell Entrapment within the Chitosan Hydrogel and Antibacterial Property of Extracted Chitosan

    Directory of Open Access Journals (Sweden)

    Nafise Sadat Majidi

    2016-09-01

    Full Text Available Background:   Chitosan is unbranched polysaccharide composed of D-glucosamine and N-acetyl-D-glucosamine. Chitosan, derived from shrimp shell, has broad antimicrobial properties against Gram-negative, Gram-positive bacteria and fungi. Methods:  Chitosan was extracted from shrimp shell and studied for cell entrapment and anti-bacterial properties. The hydrogel chitosan was used as the beads for cell entrapment and chitosan beads were designed to deliver cells and nutrients. These data confirmed with flow cytometric analyses.                 Results:   Experimental results exhibited that internal diffusion through the chitosan matrix was the main mechanism for whole gelation by TPP (Tri-polyphosphate. The minimum inhibitory concentration (MIC for chitosan against Staphylococcus aureus and Escherichia coli was 16 and 32 μg/ml respectively. Conclusion:  Despite the antimicrobial properties of chitosan, trapped bacteria in the gel network were alive and were chelated indicating that their access to the outside was limited.

  4. Flow Cytometric Applicability of Fluorescent Vitality Probes on Phytoplankton

    NARCIS (Netherlands)

    Peperzak, L.; Brussaard, C.P.D.

    2011-01-01

    The applicability of six fluorescent probes (four esterase probes: acetoxymethyl ester of Calcein [Calcein-AM], 5-chloromethylfluorescein diacetate [CMFDA], fluorescein diacetate [FDA], and 2',7'-dichlorofluorescein diacetate [H(2)DCFDA]; and two membrane probes: bis-(1,3-dibutylbarbituric acid)

  5. Comparison of Five Nuclear Isolation Buffers for Flow Cytometric ...

    African Journals Online (AJOL)

    Jocky

    2012-02-23

    Feb 23, 2012 ... factor as a measure of sample quality (%DF) and nuclear yield factor (YF) in order to compare the quantity of nuclei in suspension. The following equations were used: Estimation of DNA contents for cultivars classification. Young leaves of Deli Dura, Pisifera and hybrid Tenera trees were prepared following ...

  6. Flow Cytometric Ploidy Determination of Oral Premalignant and Malignant Lesions

    Science.gov (United States)

    1990-01-01

    identifiable lesions, some were associated with oral white lesions, either concomitant or precedent. These white lesions were referred to as leukoplakia , a...widely variable results. These authors undertook a clinical-pathologic correlation of oral leukoplakia encountered in the biopsy services of two...with oral leukoplakia for an average period of 7.2 years. All lesions were more than one centimeter in size and had been present and observed for a

  7. Howard University Flow Cytometric Sorter For Research and Education

    Science.gov (United States)

    2015-08-04

    based on beta -D- galactosidase activity after transduction of Escherichia coli lacZ. Proceedings of the National Academy of Sciences of the United... beta -D- galactosidase activity after transduction of Escherichia coli lacZ. Proceedings of the National Academy of Sciences of the United States of

  8. Rapid Flow cytometric prenatal diagnosis of primary immunodeficiency (PID) disorders.

    Science.gov (United States)

    Mishra, Anju; Gupta, Maya; Dalvi, Aparna; Ghosh, Kanjaksha; Madkaikar, Manisha

    2014-04-01

    Primary Immunodeficiency diseases (PID) are a heterogeneous group of inherited disorders of immune system. Immunophenotypic evaluation of PIDs using flowcytometry provides important clues for diagnosis of these disorders, though confirmation requires identification of underlying molecular defects. Prenatal diagnosis (PND) forms an important component of management in families affected with severe PID. However, molecular diagnostic facilities for each of these diseases are not available and may not be possible to perform in all cases. In such scenario we opted for phenotypic prenatal diagnosis by cordocentesis for families with index case having immunophenotypically well characterized PID. Normal reference ranges of lymphocyte subsets, CD 18/CD11 integrins on leukocytes, MHC class II expression and oxidative burst activity of fetal neutrophils at 18 weeks of gestation were previously established on 30 cord blood samples. PND was performed in 13 families with PIDs. Maternal contamination was ruled out by VNTR analysis. Out of 13 fetuses, nine were found to be unaffected (three cases with leukocyte adhesion deficiency (LAD-I), four cases with severe combined immunodeficiency diseases (SCID), one with X-linked agammaglobulinemia (XLA), and one with chronic granulomatous disease (CGD)] and three were found to be affected (one with T-B+NK-SCID, one with MHC class II deficiency and one with LAD-I). Diagnosis was confirmed by testing the cord blood samples after delivery and further follow-up of the children. In one family diagnosis could not be offered due to maternal contamination. No procedure related complications were observed. Flowcytometry offers rapid and sensitive method for prenatal diagnosis and genetic counseling for selected phenotypically well characterized PID in cases where molecular diagnostic facilities are not available.

  9. Flow cytometric detection of viruses in the Zuari estuary, Goa

    Digital Repository Service at National Institute of Oceanography (India)

    Mitbavkar, S.; Rajaneesh, K.M.; SathishKumar, P.

    abundance 3 . Viruses are the smallest known organisms (20–200 nm) with simple biological structures consist- ing of nucleic acid, either DNA or RNA (single- or double-stranded), with a pro- tein coat (capsid). Viruses are known to infect prokaryo- tes... in the microbial loop. Because prokaryotes and autotrophic and heterotrophic protists play pivotal roles in the biogeochemical cycles and global ocean functioning, viral infections of these groups of organ- ism have important ecological conse- quences 2...

  10. Chaotic Dynamics of Red Blood Cells in a Sinusoidal Flow

    Science.gov (United States)

    Dupire, Jules; Abkarian, Manouk; Viallat, Annie

    2010-04-01

    We show that the motion of individual red blood cells in an oscillating moderate shear flow is described by a nonlinear system of three coupled oscillators. Our experiments reveal that the cell tank treads and tumbles either in a stable way with synchronized cell inclination, membrane rotation and hydrodynamic oscillations, or in an irregular way, very sensitively to initial conditions. By adapting our model described previously, we determine the theoretical diagram for the red cell motion in a sinusoidal flow close to physiological shear stresses and flow variation frequencies and reveal large domains of chaotic motions. Finally, fitting our observations allows a characterization of cell viscosity and membrane elasticity.

  11. Cytometric Approach for Detection of Encephalitozoon intestinalis, an Emergent Agent▿

    Science.gov (United States)

    Barbosa, Joana; Rodrigues, Acácio Gonçalves; Pina-Vaz, Cidália

    2009-01-01

    Encephalitozoon intestinalis is responsible for intestinal disease in patients with AIDS and immunocompetent patients. The infectious form is a small spore that is resistant to water treatment procedures. Its detection is very important, but detection is very cumbersome and time-consuming. Our main objective was to develop and optimize a specific flow cytometric (FC) protocol for the detection of E. intestinalis in hospital tap water and human feces. To determine the optimal specific antibody (Microspor-FA) concentration, a known concentration of E. intestinalis spores (Waterborne, Inc.) was suspended in hospital tap water and stool specimens with different concentrations of Microspor-FA, and the tap water and stool specimens were incubated under different conditions. The sensitivity limit and specificity were also evaluated. To study spore infectivity, double staining with propidium iodide (PI) and Microspor-FA was undertaken. Distinct approaches for filtration and centrifugation of the stool specimens were used. E. intestinalis spores stained with 10 μg/ml of Microspor-FA at 25°C overnight provided the best results. The detection limit was 5 × 104 spores/ml, and good specificity was demonstrated. Simultaneous staining with Microspor-FA and PI ensured that the E. intestinalis spores were dead and therefore noninfectious. With the stool specimens, better spore recovery was observed with a saturated solution of NaCl and centrifugation at 1,500 × g for 15 min. A new approach for the detection of E. intestinalis from tap water or human feces that ensures that the spores are not viable is now available and represents an important step for the prevention of this threat to public health. PMID:19439525

  12. Tricyclic antidepressant-induced lipidosis in human peripheral monocytes in vitro, as well as in a monocyte-derived cell line, as monitored by spectrofluorimetry and flow cytometry after staining with Nile red.

    Science.gov (United States)

    Xia, Z; Appelkvist, E L; DePierre, J W; Nässberger, L

    1997-05-15

    Human mono- and lymphocytes from peripheral blood and the monoblastoid cell line U-937 were used in this in vitro study of drug-induced lipidosis. Mono- and lymphocytes were exposed for 4 days to three different tricyclic antidepressants (TCAs), imipramine (25 microM), clomipramine (10 microM) and citalopram (80 microM). The lipophilic fluorophore Nile red, which stains intracellular lipid structures selectively, was used as a lipid probe. Fluorescence microscopy, spectrofluorimetry and flow cytometry were used to detect cellular lipidosis, as verified by electron microscopy. Our results demonstrate that imipramine, clomipramine and citalopram induce lipidosis in monocytes and U-937 cells, but not in lymphocytes. An accurate quantitation of induced intracellular lipidosis can be achieved by spectrofluorimetric and flow cytometric analysis.

  13. ICCS/ESCCA consensus guidelines to detect GPI-deficient cells in paroxysmal nocturnal hemoglobinuria (PNH) and related disorders part 4 - assay validation and quality assurance.

    Science.gov (United States)

    Oldaker, Teri; Whitby, Liam; Saber, Maryam; Holden, Jeannine; Wallace, Paul K; Litwin, Virginia

    2018-01-01

    Over the past six years, a diverse group of stakeholders have put forth recommendations regarding the analytical validation of flow cytometric methods and described in detail the differences between cell-based and traditional soluble analyte assay validations. This manuscript is based on these general recommendations as well as the published experience of experts in the area of PNH testing. The goal is to provide practical assay-specific guidelines for the validation of high-sensitivity flow cytometric PNH assays. Examples of the reports and validation data described herein are provided in Supporting Information. © 2017 International Clinical Cytometry Society. © 2017 International Clinical Cytometry Society.

  14. Merging Mixture Components for Cell Population Identification in Flow Cytometry

    Directory of Open Access Journals (Sweden)

    Greg Finak

    2009-01-01

    Full Text Available We present a framework for the identification of cell subpopulations in flow cytometry data based on merging mixture components using the flowClust methodology. We show that the cluster merging algorithm under our framework improves model fit and provides a better estimate of the number of distinct cell subpopulations than either Gaussian mixture models or flowClust, especially for complicated flow cytometry data distributions. Our framework allows the automated selection of the number of distinct cell subpopulations and we are able to identify cases where the algorithm fails, thus making it suitable for application in a high throughput FCM analysis pipeline. Furthermore, we demonstrate a method for summarizing complex merged cell subpopulations in a simple manner that integrates with the existing flowClust framework and enables downstream data analysis. We demonstrate the performance of our framework on simulated and real FCM data. The software is available in the flowMerge package through the Bioconductor project.

  15. Measurement of circulating cell-derived microparticles by flow cytometry: sources of variability within the assay.

    Science.gov (United States)

    Ayers, Lisa; Kohler, Malcolm; Harrison, Paul; Sargent, Ian; Dragovic, Rebecca; Schaap, Marianne; Nieuwland, Rienk; Brooks, Susan A; Ferry, Berne

    2011-04-01

    Circulating cell-derived microparticles (MPs) have been implicated in several disease processes and elevated levels are found in many pathological conditions. The detection and accurate measurement of MPs, although attracting widespread interest, is hampered by a lack of standardisation. The aim of this study was to establish a reliable flow cytometric assay to measure distinct subtypes of MPs in disease and to identify any significant causes of variability in MP quantification. Circulating MPs within plasma were identified by their phenotype (platelet, endothelial, leukocyte and annexin-V positivity (AnnV+). The influence of key variables (i.e. time between venepuncture and centrifugation, washing steps, the number of centrifugation steps, freezing/long-term storage and temperature of thawing) on MP measurement were investigated. Increasing time between venepuncture and centrifugation leads to increased MP levels. Washing samples results in decreased AnnV+MPs (P=0.002) and platelet-derived MPs (PMPs) (P=0.002). Double centrifugation of MPs prior to freezing decreases numbers of AnnV+MPs (P=0.0004) and PMPs (P=0.0004). A single freeze thaw cycle of samples led to an increase in AnnV+MPs (P=0.0020) and PMPs (P=0.0039). Long-term storage of MP samples at -80° resulted in decreased MP levels. This study found that minor protocol changes significantly affected MP levels. This is one of the first studies attempting to standardise a method for obtaining and measuring circulating MPs. Standardisation will be essential for successful development of MP technologies, allowing direct comparison of results between studies and leading to a greater understanding of MPs in disease. Crown Copyright © 2010. Published by Elsevier Ltd. All rights reserved.

  16. Age-related macular degeneration is associated with increased proportion of CD56(+) T cells in peripheral blood

    DEFF Research Database (Denmark)

    Faber, Carsten; Singh, Amardeep; Krüger Falk, Mads

    2013-01-01

    samples were processed for flow cytometric analysis of T-cell populations. Plasma samples were analyzed for anti-cytomegalovirus (CMV) immunoglobulin (Ig)G and complement factor H (CFH) Y402H genotype. The diagnosis of AMD was made according to the Clinical Age-Related Maculopathy Staging System. MAIN...

  17. Flow rate calibration. III. The use of stabilized biostandards to calibrate the flow rate and calculate absolute CD4+ T-cell counts.

    Science.gov (United States)

    Walker, Clare L; Whitby, Liam; Granger, Viv; Storie, Ian; Reilly, John T; Barnett, David

    2006-05-01

    We have previously reported a flow rate calibration method for the determination of absolute CD4(+) T-lymphocyte counts that removes the need for the addition of latex beads to each sample. However, a limitation with this approach is that a calibration factor (CF) needs to be applied to adjust for differences in viscosity between latex bead suspensions and biological specimens. We have also demonstrated the value of using stabilized whole blood samples in external quality assessment (EQA) studies; such samples have a stable absolute lymphocyte count for over 1 year, at 4 degrees C. It was successfully demonstrated that this material can be used as a flow rate biocalibration (FRB) material for use as a flow cytometric control to provide a sample with a known CD4(+) T-lymphocyte count. Such material has advantages over latex bead technology as it can act as a full process control as well as having the same matrix and viscosity characteristics as the test material, thus removing the need for a CF. In this study, we have analyzed 268 consecutive normal, abnormal, and HIV(+) samples using FRB, incorporating the PanLeucoGating approach and compared this to the MultiSet method, defined as the predicate. Percentage similarity statistics revealed the following: 0-3,000 CD4(+) cells/mul mean percentage difference (MPD; bias) 1.2%, 95% CI of 5.6-8%; 0-200 CD4(+) cells/microl MPD of 1.25%, 95% CI of 11.63-14.13%; 201-500 CD4(+) cells/microl MPD of 1%, 95% CI of 4.6-6.6%. This study demonstrates that stabilized whole blood can be used for FRB. It has the advantage of being a full process control, in addition to costing less than latex beads with highly comparable results. As bench top flow cytometers are extremely stable, this is a low cost and robust alternative to bead based methods for generating absolute CD4 counts. Copyright 2006 International Society for Analytical Cytology.

  18. S-phase-dependent cell cycle disturbances caused by Aleutian mink disease parvovirus

    DEFF Research Database (Denmark)

    Oleksiewicz, M.B.; Alexandersen, Søren

    1997-01-01

    arrest occurred exclusively in cells containing de novo-synthesized viral nonstructural (NS) proteins. Production of ADV NS proteins, indicative of ADV replication, was triggered during S-phase traverse. The NS+ cells that were generated during later parts of S phase did not undergo cytokinesis...... with subthreshold levels of ADV products through the late S/G(2) block and, consequently, that the binary pattern of ADV-induced cell cycle arrest may be governed merely by viral replication levels within a single S phase. Flow cytometric analysis of propidium iodide fluorescence and bromodeoxyuridine uptake showed......We examined replication of the autonomous parovirus Aleutian mink disease parovirus (ADV) in relation to cell cycle progression of permissive Crandell feline kidney (CRFK) cells. Flow cytometric analysis showed that ADV caused a composite, binary pattern of cell cycle arrest. ADV-induced cell cycle...

  19. Polymer electrolyte fuel cells: flow field for efficient air operation

    Energy Technology Data Exchange (ETDEWEB)

    Buechi, F.N.; Tsukada, A.; Haas, O.; Scherer, G.G. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-06-01

    A new flow field was designed for a polymer electrolyte fuel cell stack with an active area of 200 cm{sup 2} for operation at low air stoichiometry and low air over pressure. Optimum of gas flow and channel dimensions were calculated based on the required pressure drop in the fluid. Single cells and a bi-cell stack with the new flow field show an improved current/voltage characteristic when operated at low air stoichiometries as compared to that of the previous non optimized design. (author) 4 figs., 3 refs.

  20. Use of flow cytometry for the adhesion analysis of Streptococcus pyogenes mutant strains to epithelial cells: investigation of the possible role of surface pullulanase and cysteine protease, and the transcriptional regulator Rgg

    Directory of Open Access Journals (Sweden)

    Finne Jukka

    2006-02-01

    Full Text Available Abstract Background Flow cytometry based adherence assay is a potentially powerful but little used method in the study of bacterial binding to host structures. We have previously characterized a glycoprotein-binding activity in Streptococcus pyogenes called 'strepadhesin' binding to thyroglobulin, submaxillar mucin, fetuin and asialofetuin. We have identified surface-associated pullulanase (PulA and cysteine protease (SpeB as carriers of strepadhesin activity. In the present paper, we investigated the use of flow cytometry as a method to study the binding of Rgg, SpeB and PulA knock-out strains to cultured human epithelial cells. Results Streptococcal mutants were readily labelled with CFDA-SE and their binding to epithelial cells could be effectively studied by flow cytometry. A strain deficient in Rgg expression showed increased binding to the analyzed epithelial cell lines of various origin. Inactivation of SpeB had no effect on the adhesion, while PulA knock-out strains displayed decreased binding to the cell lines. Conclusion These results suggest that the flow cytometric assay is a valuable tool in the analysis of S. pyogenes adherence to host cells. It appears to be an efficient and sensitive tool for the characterization of interactions between the bacteria and the host at the molecular level. The results also suggest a role for Rgg regulated surface molecules, like PulA, in the adhesion of S. pyogenes to host cells.

  1. Partitioning of red blood cell aggregates in bifurcating microscale flows

    Science.gov (United States)

    Kaliviotis, E.; Sherwood, J. M.; Balabani, S.

    2017-03-01

    Microvascular flows are often considered to be free of red blood cell aggregates, however, recent studies have demonstrated that aggregates are present throughout the microvasculature, affecting cell distribution and blood perfusion. This work reports on the spatial distribution of red blood cell aggregates in a T-shaped bifurcation on the scale of a large microvessel. Non-aggregating and aggregating human red blood cell suspensions were studied for a range of flow splits in the daughter branches of the bifurcation. Aggregate sizes were determined using image processing. The mean aggregate size was marginally increased in the daughter branches for a range of flow rates, mainly due to the lower shear conditions and the close cell and aggregate proximity therein. A counterintuitive decrease in the mean aggregate size was apparent in the lower flow rate branches. This was attributed to the existence of regions depleted by aggregates of certain sizes in the parent branch, and to the change in the exact flow split location in the T-junction with flow ratio. The findings of the present investigation may have significant implications for microvascular flows and may help explain why the effects of physiological RBC aggregation are not deleterious in terms of in vivo vascular resistance.

  2. Local transport phenomena and cell performance of PEM fuel cells with various serpentine flow field designs

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xiao-Dong [Department of Thermal Engineering, School of Mechanical Engineering, University of Science and Technology Beijing, Beijing 100083 (China); Duan, Yuan-Yuan [Key Laboratory for Thermal Science and Power Engineering of Ministry of Education, Tsinghua University, Beijing 100084 (China); Yan, Wei-Mon [Department of Mechatronic Engineering, Huafan University, Taipei 22305 (China); Peng, Xiao-Feng [Laboratory of Phase Change and Interfacial Transport Phenomena, Tsinghua University, Beijing 100084 (China)

    2008-01-03

    The flow field design in bipolar plates is very important for improving reactant utilization and liquid water removal in proton exchange membrane fuel cells (PEMFCs). A three-dimensional model was used to analyze the effect of the design parameters in the bipolar plates, including the number of flow channel bends, number of serpentine flow channels and the flow channel width ratio, on the cell performance of miniature PEMFCs with the serpentine flow field. The effect of the liquid water formation on the porosities of the porous layers was also taken into account in the model while the complex two-phase flow was neglected. The predictions show that (1) for the single serpentine flow field, the cell performance improves as the number of flow channel bends increases; (2) the single serpentine flow field has better performance than the double and triple serpentine flow fields; (3) the cell performance only improves slowly as the flow channel width increases. The effects of these design parameters on the cell performance were evaluated based on the local oxygen mass flow rates and liquid water distributions in the cells. Analysis of the pressure drops showed that for these miniature PEMFCs, the energy losses due to the pressure drops can be neglected because they are far less than the cell output power. (author)

  3. Modeling two-phase flow in PEM fuel cell channels

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yun; Basu, Suman; Wang, Chao-Yang [Electrochemical Engine Center (ECEC), and Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, University Park, PA 16802 (United States)

    2008-05-01

    This paper is concerned with the simultaneous flow of liquid water and gaseous reactants in mini-channels of a proton exchange membrane (PEM) fuel cell. Envisaging the mini-channels as structured and ordered porous media, we develop a continuum model of two-phase channel flow based on two-phase Darcy's law and the M{sup 2} formalism, which allow estimate of the parameters key to fuel cell operation such as overall pressure drop and liquid saturation profiles along the axial flow direction. Analytical solutions of liquid water saturation and species concentrations along the channel are derived to explore the dependences of these physical variables vital to cell performance on operating parameters such as flow stoichiometric ratio and relative humility. The two-phase channel model is further implemented for three-dimensional numerical simulations of two-phase, multi-component transport in a single fuel-cell channel. Three issues critical to optimizing channel design and mitigating channel flooding in PEM fuel cells are fully discussed: liquid water buildup towards the fuel cell outlet, saturation spike in the vicinity of flow cross-sectional heterogeneity, and two-phase pressure drop. Both the two-phase model and analytical solutions presented in this paper may be applicable to more general two-phase flow phenomena through mini- and micro-channels. (author)

  4. Flow field measurements in the cell culture unit

    Science.gov (United States)

    Walker, Stephen; Wilder, Mike; Dimanlig, Arsenio; Jagger, Justin; Searby, Nancy

    2002-01-01

    The cell culture unit (CCU) is being designed to support cell growth for long-duration life science experiments on the International Space Station (ISS). The CCU is a perfused loop system that provides a fluid environment for controlled cell growth experiments within cell specimen chambers (CSCs), and is intended to accommodate diverse cell specimen types. Many of the functional requirements depend on the fluid flow field within the CSC (e.g., feeding and gas management). A design goal of the CCU is to match, within experimental limits, all environmental conditions, other than the effects of gravity on the cells, whether the hardware is in microgravity ( micro g), normal Earth gravity, or up to 2g on the ISS centrifuge. In order to achieve this goal, two steps are being taken. The first step is to characterize the environmental conditions of current 1g cell biology experiments being performed in laboratories using ground-based hardware. The second step is to ensure that the design of the CCU allows the fluid flow conditions found in 1g to be replicated from microgravity up to 2g. The techniques that are being used to take these steps include flow visualization, particle image velocimetry (PIV), and computational fluid dynamics (CFD). Flow visualization using the injection of dye has been used to gain a global perspective of the characteristics of the CSC flow field. To characterize laboratory cell culture conditions, PIV is being used to determine the flow field parameters of cell suspension cultures grown in Erlenmeyer flasks on orbital shakers. These measured parameters will be compared to PIV measurements in the CSCs to ensure that the flow field that cells encounter in CSCs is within the bounds determined for typical laboratory experiments. Using CFD, a detailed simulation is being developed to predict the flow field within the CSC for a wide variety of flow conditions, including microgravity environments. Results from all these measurements and analyses of the

  5. Fluid flow plate for decreased density of fuel cell assembly

    Science.gov (United States)

    Vitale, Nicholas G.

    1999-01-01

    A fluid flow plate includes first and second outward faces. Each of the outward faces has a flow channel thereon for carrying respective fluid. At least one of the fluids serves as reactant fluid for a fuel cell of a fuel cell assembly. One or more pockets are formed between the first and second outward faces for decreasing density of the fluid flow plate. A given flow channel can include one or more end sections and an intermediate section. An interposed member can be positioned between the outward faces at an interface between an intermediate section, of one of the outward faces, and an end section, of that outward face. The interposed member can serve to isolate the reactant fluid from the opposing outward face. The intermediate section(s) of flow channel(s) on an outward face are preferably formed as a folded expanse.

  6. Multi-reflection photometric flow cell for use in flow injection analysis of estuarine waters

    International Nuclear Information System (INIS)

    Ellis, Peter S.; Lyddy-Meaney, Amanda J.; Worsfold, Paul J.; McKelvie, Ian D.

    2003-01-01

    A multi-reflection flow cell suitable for flow analysis is described. Light from an LED is directed through an optical fibre into a silver coated capillary through a sidewall aperture, and emerges through a similar aperture 10 mm along the capillary after undergoing an estimated 19 reflections. This process provides a sensitivity enhancement of approximately 2.5 compared with a conventional z-cell of the same nominal path length. This enhancement is due to both the increased optical path length achieved by multiple reflection of the light beam through the sample, and minimization of physical dispersion by the use of a short, small internal diameter capillary as the flow cell. The optical design of this flow cell also minimizes the Schlieren effect. Optical and hydrodynamic characteristics of this multi-reflection cell have been evaluated using a series of bromothymol blue dye studies. Application of the flow cell to the determination of reactive phosphorus in estuarine waters with wide variation in salinity and refractive index is also described

  7. Flow: Statistics, visualization and informatics for flow cytometry

    Directory of Open Access Journals (Sweden)

    Kepler Thomas B

    2008-06-01

    Full Text Available Abstract Flow is an open source software application for clinical and experimental researchers to perform exploratory data analysis, clustering and annotation of flow cytometric data. Flow is an extensible system that offers the ease of use commonly found in commercial flow cytometry software packages and the statistical power of academic packages like the R BioConductor project.

  8. Separation of cancer cells using vortical microfluidic flows.

    Science.gov (United States)

    Haddadi, Hamed; Naghsh-Nilchi, Hamed; Di Carlo, Dino

    2018-01-01

    Label-free separation of viable cancer cells using vortical microfluidic flows has been introduced as a feasible cell collection method in oncological studies. Besides the clinical importance, the physics of particle interactions with the vortex that forms in a wall-confined geometry of a microchannel is a relatively new area of fluid dynamics. In our previous work [Haddadi and Di Carlo, J. Fluid. Mech. 811 , 436-467 (2017)], we have introduced distinct aspects of inertial flow of dilute suspensions over cavities in a microchannel such as breakdown of the separatrix and formation of stable limit cycle orbits for finite size polystyrene particles. In this work, we extend our experiments to address the engineering-physics of cancer cell entrapment in microfluidic cavities. We begin by studying the effects of the channel width and device height on the morphology of the vortex, which has not been discussed in our previous work. The stable limit cycle orbits of finite size cancer cells are then presented. We demonstrate effects of the separatrix breakdown and the limit cycle formation on the operation of the cancer cell separation platform. By studying the flow of dilute cell suspensions over the cavities, we further develop the notion of the cavity capacity and the relative rate of cell accumulation as optimization criteria which connect the device geometry with the flow. Finally, we discuss the proper placement of multiple cavities inside a microchannel for improved cell entrapment.

  9. Determinants of resting cerebral blood flow in sickle cell disease

    NARCIS (Netherlands)

    Bush, Adam M.; Borzage, Matthew T.; Choi, Soyoung; Václavů, Lena; Tamrazi, Benita; Nederveen, Aart J.; Coates, Thomas D.; Wood, John C.

    2016-01-01

    Stroke is common in children with sickle cell disease and results from an imbalance in oxygen supply and demand. Cerebral blood flow (CBF) is increased in patients with sickle cell disease to compensate for their anemia, but adequacy of their oxygen delivery has not been systematically demonstrated.

  10. Flow Electrolysis Cells for the Synthetic Organic Chemistry Laboratory.

    Science.gov (United States)

    Pletcher, Derek; Green, Robert A; Brown, Richard C D

    2017-09-18

    Electrosynthesis has much to offer to the synthetic organic chemist. But in order to be widely accepted as a routine procedure in an organic synthesis laboratory, electrosynthesis needs to be presented in a much more user-friendly way. The literature is largely based on electrolysis in a glass beaker or H-cells that often give poor performance for synthesis with a very slow rate of conversion and, often, low selectivity and reproducibility. Flow cells can lead to much improved performance. Electrolysis is participating in the trend toward continuous flow synthesis, and this has led to a number of innovations in flow cell design that make possible selective syntheses with high conversion of reactant to product with a single passage of the reactant solution through the cell. In addition, the needs of the synthetic organic chemist can often be met by flow cells operating with recycle of the reactant solution. These cells give a high rate of product formation while the reactant concentration is high, but they perform best at low conversion. Both approaches are considered in this review and the important features of each cell design are discussed. Throughout, the application of the cell designs is illustrated with syntheses that have been reported.

  11. Mechanical stimulation of bone cells using fluid flow

    NARCIS (Netherlands)

    Huesa, C.; Bakker, A.D.

    2012-01-01

    This chapter describes several methods suitable for mechanically stimulating monolayers of bone cells by fluid shear stress (FSS) in vitro. Fluid flow is generated by pumping culture medium through two parallel plates, one of which contains a monolayer of cells. Methods for measuring nitric oxide

  12. Microfluidic flow cells for studies of electrochemical reactions

    OpenAIRE

    Møinichen, Christine

    2012-01-01

    In this project the main goal was to establish a routine for making a microfluidic flow cell (MFFC) using soft lithography methods, and test the flow cell with different electrolytes, sulphuric acid and a ruthenium red-ox couple, and eventually use the established routine to make a microfluidic fuel cell and test it. A routine was established using the negative photoresist ma-N405. The photoresist was overdeveloped to make sure an undercut profile was reached, which proved to be necessary for...

  13. Flow cytometry based micronucleus assay for evaluation of genotoxic potential of 2-ACBs in hepatic cells HepG2

    Energy Technology Data Exchange (ETDEWEB)

    Barbezan, Angélica B.; Santos, Carla J.B.; Carvalho, Luma R.; Vieira, Daniel P.; Villavicêncio, Anna L.C.H., E-mail: abarbezan@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil); Santelli, Glaucia M.M. [Universidade de São Paulo (USP), SP (Brazil). Departamento de Biologia Celular e do Desenvolvimento

    2017-07-01

    Food irradiation is approved for use in more than 60 countries for applications and purposes in a wide variety of foods, being an effective and safe method for preservation and long-term storage. 2-Alkylcyclobutanones (2-ACBs) are the only known radiolytic products generated from foods that contain fatty acids (Triglycerides) when irradiated. The acids analyzed in this study are palmitic and stearic, which when irradiated form 2-Dodecylcyclobutanones (2-dDCB) and 2-Tetradecylcyclobutanone (2-tDCB). Part of the 2-ACBs ingested is excreted through feces and part is deposited in adipose tissues. In vitro studies so far have been only in colon cells. The work used a human hepatoma cell line (HepG2) since the accumulation of fat in this organ is quite common. Micronucleus test was selected to evaluate possible genotoxic effects of 2-dDCB and 2-tDCB compounds when exposed to high concentrations (447, 1422 and 2235 μM) for 4 and 24 hours. Tests were performed in quadriplicates using flow cytometric analysis. None detectable genotoxic damage was observed after 4 hours of exposure to the compounds, and cytotoxic effects were only significant at the highest concentration (2235 μM) of 2-dDCB. After 24 hours of exposure, slight genotoxic damage was observed at all concentrations evaluated, and cytotoxic effects were only present when exposed to compound 2-tDCB. Although there is a genotoxic and cytotoxic effect in some of the situations tested, the two compounds predominantly induced proliferation reduction effects of this hepatic tumor cell line. (author)

  14. Cell proliferation alterations in Chlorella cells under stress conditions

    International Nuclear Information System (INIS)

    Rioboo, Carmen; O'Connor, Jose Enrique; Prado, Raquel; Herrero, Concepcion; Cid, Angeles

    2009-01-01

    Very little is known about growth and proliferation in relation to the cell cycle regulation of algae. The lack of knowledge is even greater when referring to the potential toxic effects of pollutants on microalgal cell division. To assess the effect of terbutryn, a triazine herbicide, on the proliferation of the freshwater microalga Chlorella vulgaris three flow cytometric approaches were used: (1) in vivo cell division using 5-,6-carboxyfluorescein diacetate succinimidyl ester (CFSE) staining was measured, (2) the growth kinetics were determined by cytometric cell counting and (3) cell viability was evaluated with the membrane-impermeable double-stranded nucleic acid stain propidium iodide (PI). The results obtained in the growth kinetics study using CFSE to identify the microalgal cell progeny were consistent with those determined by cytometric cell counting. In all C. vulgaris cultures, each mother cell had undergone only one round of division through the 96 h of assay and the cell division occurred during the dark period. Cell division of the cultures exposed to the herbicide was asynchronous. Terbutryn altered the normal number of daughter cells (4 autospores) obtained from each mother cell. The number was only two in the cultures treated with 250 nM. The duration of the lag phase after the exposure to terbutryn could be dependent on the existence of a critical cell size to activate cytoplasmic division. Cell size, complexity and fluorescence of chlorophyll a of the microalgal cells presented a marked light/dark (day/night) cycle, except in the non-dividing 500 nM cultures, where terbutryn arrested cell division at the beginning of the cycle. Viability results showed that terbutryn has an algastatic effect in C. vulgaris cells at this concentration. The rapid and precise determination of cell proliferation by CFSE staining has allowed us to develop a model for assessing both the cell cycle of C. vulgaris and the in vivo effects of pollutants on growth and

  15. Cell proliferation alterations in Chlorella cells under stress conditions

    Energy Technology Data Exchange (ETDEWEB)

    Rioboo, Carmen [Laboratorio de Microbiologia, Facultad de Ciencias, Universidad de A Coruna, Campus da Zapateira s/n, 15008 A Coruna (Spain); O' Connor, Jose Enrique [Laboratorio de Citomica, Unidad Mixta de Investigacion CIPF-UVEG, Centro de Investigacion Principe Felipe, Avda. Autopista del Saler, 16, 46013 Valencia (Spain); Prado, Raquel; Herrero, Concepcion [Laboratorio de Microbiologia, Facultad de Ciencias, Universidad de A Coruna, Campus da Zapateira s/n, 15008 A Coruna (Spain); Cid, Angeles, E-mail: cid@udc.es [Laboratorio de Microbiologia, Facultad de Ciencias, Universidad de A Coruna, Campus da Zapateira s/n, 15008 A Coruna (Spain)

    2009-09-14

    Very little is known about growth and proliferation in relation to the cell cycle regulation of algae. The lack of knowledge is even greater when referring to the potential toxic effects of pollutants on microalgal cell division. To assess the effect of terbutryn, a triazine herbicide, on the proliferation of the freshwater microalga Chlorella vulgaris three flow cytometric approaches were used: (1) in vivo cell division using 5-,6-carboxyfluorescein diacetate succinimidyl ester (CFSE) staining was measured, (2) the growth kinetics were determined by cytometric cell counting and (3) cell viability was evaluated with the membrane-impermeable double-stranded nucleic acid stain propidium iodide (PI). The results obtained in the growth kinetics study using CFSE to identify the microalgal cell progeny were consistent with those determined by cytometric cell counting. In all C. vulgaris cultures, each mother cell had undergone only one round of division through the 96 h of assay and the cell division occurred during the dark period. Cell division of the cultures exposed to the herbicide was asynchronous. Terbutryn altered the normal number of daughter cells (4 autospores) obtained from each mother cell. The number was only two in the cultures treated with 250 nM. The duration of the lag phase after the exposure to terbutryn could be dependent on the existence of a critical cell size to activate cytoplasmic division. Cell size, complexity and fluorescence of chlorophyll a of the microalgal cells presented a marked light/dark (day/night) cycle, except in the non-dividing 500 nM cultures, where terbutryn arrested cell division at the beginning of the cycle. Viability results showed that terbutryn has an algastatic effect in C. vulgaris cells at this concentration. The rapid and precise determination of cell proliferation by CFSE staining has allowed us to develop a model for assessing both the cell cycle of C. vulgaris and the in vivo effects of pollutants on growth and

  16. Measuring Actin Flow in 3D Cell Protrusions

    Science.gov (United States)

    Chiu, Chi-Li; Digman, Michelle A.; Gratton, Enrico

    2013-01-01

    Actin dynamics is important in determining cell shape, tension, and migration. Methods such as fluorescent speckle microscopy and spatial temporal image correlation spectroscopy have been used to capture high-resolution actin turnover dynamics within cells in two dimensions. However, these methods are not directly applicable in 3D due to lower resolution and poor contrast. Here, we propose to capture actin flow in 3D with high spatial-temporal resolution by combining nanoscale precise imaging by rapid beam oscillation and fluctuation spectroscopy techniques. To measure the actin flow along cell protrusions in cell expressing actin-eGFP cultured in a type I collagen matrix, the laser was orbited around the protrusion and its trajectory was modulated in a clover-shaped pattern perpendicularly to the protrusion. Orbits were also alternated at two positions closely spaced along the protrusion axis. The pair cross-correlation function was applied to the fluorescence fluctuation from these two positions to capture the flow of actin. Measurements done on nonmoving cellular protrusion tips showed no pair-correlation at two orbital positions indicating a lack of flow of F-actin bundles. However, in some protrusions, the pair-correlation approach revealed directional flow of F-actin bundles near the protrusion surface with flow rates in the range of ∼1 μm/min, comparable to results in two dimensions using fluorescent speckle microscopy. Furthermore, we found that the actin flow rate is related to the distance to the protrusion tip. We also observed collagen deformation by concomitantly detecting collagen fibers with reflectance detection during these actin motions. The implementation of the nanoscale precise imaging by rapid beam oscillation method with a cloverleaf-shaped trajectory in conjunction with the pair cross-correlation function method provides a quantitative way of capturing dynamic flows and organization of proteins during cell migration in 3D in conditions of

  17. Supercontinuum white light lasers for flow cytometry

    Science.gov (United States)

    Telford, William G.; Subach, Fedor V.; Verkhusha, Vladislav V.

    2009-01-01

    Excitation of fluorescent probes for flow cytometry has traditionally been limited to a few discrete laser lines, an inherent limitation in our ability to excite the vast array of fluorescent probes available for cellular analysis. In this report, we have used a supercontinuum (SC) white light laser as an excitation source for flow cytometry. By selectively filtering the wavelength of interest, almost any laser wavelength in the visible spectrum can be separated and used for flow cytometric analysis. The white light lasers used in this study were integrated into a commercial flow cytometry platform, and a series of high-transmission bandpass filters used to select wavelength ranges from the blue (~480 nm) to the long red (>700 nm). Cells labeled with a variety of fluorescent probes or expressing fluorescent proteins were then analyzed, in comparison with traditional lasers emitting at wavelengths similar to the filtered SC source. Based on a standard sensitivity metric, the white light laser bandwidths produced similar excitation levels to traditional lasers for a wide variety of fluorescent probes and expressible proteins. Sensitivity assessment using fluorescent bead arrays confirmed that the SC laser and traditional sources resulted in similar levels of detection sensitivity. Supercontinuum white light laser sources therefore have the potential to remove a significant barrier in flow cytometric analysis, namely the limitation of excitation wavelengths. Almost any visible wavelength range can be made available for excitation, allowing access to virtually any fluorescent probe, and permitting “fine-tuning” of excitation wavelength to particular probes. PMID:19072836

  18. Improved method for fluorescence cytometric immunohematology testing.

    Science.gov (United States)

    Roback, John D; Barclay, Sheilagh; Hillyer, Christopher D

    2004-02-01

    A method for accurate immunohematology testing by fluorescence cytometry (FC) was previously described. Nevertheless, the use of vacuum filtration to wash RBCs and a standard-flow cytometer for data acquisition hindered efforts to incorporate this method into an automated platform. A modified procedure was developed that used low-speed centrifugation of 96-well filter plates for RBC staining. Small-footprint benchtop capillary cytometers (PCA and PCA-96, Guava Technologies, Inc.) were used for data acquisition. Authentic clinical samples from hospitalized patients were tested for ABO group and the presence of D antigen (n = 749) as well as for the presence of RBC alloantibodies (n = 428). Challenging samples with mixed-field reactions and weak antibodies were included. Results were compared to those obtained by column agglutination technology (CAT), and discrepancies were resolved by standard tube methods. Detailed investigations of FC sensitivity and reproducibility were also performed. The modified FC method with the PCA determined the correct ABO group and D type for 98.7 percent of 520 samples, compared to 98.8 percent for CAT (p > 0.05). No-type-determined (NTD) rates were 1.2 percent for both methods. In testing for unexpected alloantibodies, FC determined the correct result for 98.6 percent of 215 samples, compared to 96.3 percent for CAT (p > 0.05). When samples were automatically acquired in the 96-well plate format with the PCA-96, 98.7 percent of 229 samples had correct ABO group and D type determined by FC, compared to 97.4 percent for CAT (p > 0.05). NTD rates were 0.9 and 2.6 percent, respectively. Antibody screens were accurate for 99.1 percent of 213 samples with the PCA-96, compared to 99.5 percent for CAT (p > 0.05). Further investigations demonstrated that FC with the PCA-96 was better than CAT at detecting weak anti-A (p < 0.0001) and alloantibodies. An improved method for FC immunohematology testing has been described. This assay was comparable

  19. Applications of Imaging Flow Cytometry for Microalgae.

    Science.gov (United States)

    Hildebrand, Mark; Davis, Aubrey; Abbriano, Raffaela; Pugsley, Haley R; Traller, Jesse C; Smith, Sarah R; Shrestha, Roshan P; Cook, Orna; Sánchez-Alvarez, Eva L; Manandhar-Shrestha, Kalpana; Alderete, Benjamin

    2016-01-01

    The ability to image large numbers of cells at high resolution enhances flow cytometric analysis of cells and cell populations. In particular, the ability to image intracellular features adds a unique aspect to analyses, and can enable correlation between molecular phenomena resulting in alterations in cellular phenotype. Unicellular microalgae are amenable to high-throughput analysis to capture the diversity of cell types in natural samples, or diverse cellular responses in clonal populations, especially using imaging cytometry. Using examples from our laboratory, we review applications of imaging cytometry, specifically using an Amnis(®) ImageStream(®)X instrument, to characterize photosynthetic microalgae. Some of these examples highlight advantages of imaging flow cytometry for certain research objectives, but we also include examples that would not necessarily require imaging and could be performed on a conventional cytometer to demonstrate other concepts in cytometric evaluation of microalgae. We demonstrate the value of these approaches for (1) analysis of populations, (2) documentation of cellular features, and (3) analysis of gene expression.

  20. Optical Flow Cell for Measuring Size, Velocity and Composition of Flowing Droplets

    Directory of Open Access Journals (Sweden)

    Sammer-ul Hassan

    2017-02-01

    Full Text Available Here an optical flow cell with two light paths is reported that can accurately quantify the size and velocity of droplets flowing through a microchannel. The flow cell can measure the time taken for droplets to pass between and through two conjoined light paths, and thereby is capable of measuring the velocities (0.2–5.45 mm/s and sizes of droplets (length > 0.8 mm. The composition of the droplet can also be accurately quantified via optical absorption measurements. The device has a small footprint and uses low-powered, low-cost components, which make it ideally suited for use in field-deployable and portable analytical devices.

  1. Aggressive natural killer-cell leukemia: Classical presentation of a rare disease

    Directory of Open Access Journals (Sweden)

    Priya M Jacob

    2014-01-01

    Full Text Available Aggressive natural killer-cell leukaemia is a rare aggressive form of natural killer-cell neoplasm. We report a case of a 40-year-old male who presented with jaundice, raised blood counts,generalised lymphadenopathy and hepatosplenomegaly. The diagnosis was established by flow cytometric analysis of bone marrow aspirate. The patient, however, succumbed to his illness within 2 weeks of starting chemotherapy. To the best of our knowledge, this is the third reported case from India.

  2. Flow rate dependency of critical wall shear stress in a radial-flow cell

    DEFF Research Database (Denmark)

    Detry, J.G.; Jensen, Bo Boye Busk; Sindic, M.

    2009-01-01

    In the present work, a radial-flow cell was used to study the removal of starch particle aggregates from several solid substrates (glass, stainless steel, polystyrene and PTFE) in order to determine the critical wall shear stress value for each case. The particle aggregates were formed by aspersion...

  3. Articular Cartilage Repair Through Muscle Cell-Based Tissue Engineering

    Science.gov (United States)

    2011-03-01

    TaqMan probe AAC-CCT-CTT- TTC -GGA-TTA-ACC-CTG-CGA- GTT. Articular cartilage defect model and cell transplanta- tion. All animal experiments were... inhalation mask. The knee joint was exposed by medial parapa- tellar incision, and the trochlear groove was exposed by lateral dislocation of the...least significant difference test. P values less than 0.05 were considered significant. RESULTS In vitro MDSC characterization. Flow cytometric analysis

  4. Cytometric analysis of shape and DNA content in mammalian sperm

    Energy Technology Data Exchange (ETDEWEB)

    Gledhill, B.L.

    1983-10-10

    Male germ cells respond dramatically to a variety of insults and are important reproductive dosimeters. Semen analyses are very useful in studies on the effects of drugs, chemicals, and environmental hazards on testicular function, male fertility and heritable germinal mutations. Sperm were analyzed by flow cytometry and slit-scan flow analysis for injury following the exposure of testes to mutagens. The utility of flow cytometry in genotoxin screening and monitoring of occupational exposure was evaluated. The technique proved valuable in separation of X- and Y-chromosome bearing sperm and the potential applicability of this technique in artificial insemination and a solution, of accurately assessing the DNA content of sperm were evaluated-with reference to determination of X- and Y-chromosome bearing sperm.

  5. Cytometric analysis of shape and DNA content in mammalian sperm

    International Nuclear Information System (INIS)

    Gledhill, B.L.

    1983-01-01

    Male germ cells respond dramatically to a variety of insults and are important reproductive dosimeters. Semen analyses are very useful in studies on the effects of drugs, chemicals, and environmental hazards on testicular function, male fertility and heritable germinal mutations. Sperm were analyzed by flow cytometry and slit-scan flow analysis for injury following the exposure of testes to mutagens. The utility of flow cytometry in genotoxin screening and monitoring of occupational exposure was evaluated. The technique proved valuable in separation of X- and Y-chromosome bearing sperm and the potential applicability of this technique in artificial insemination and a solution, of accurately assessing the DNA content of sperm were evaluated-with reference to determination of X- and Y-chromosome bearing sperm

  6. Quantitative analysis of cell migration using optical flow.

    Directory of Open Access Journals (Sweden)

    Katica Boric

    Full Text Available Neural crest cells exhibit dramatic migration behaviors as they populate their distant targets. Using a line of zebrafish expressing green fluorescent protein (sox10:EGFP in neural crest cells we developed an assay to analyze and quantify cell migration as a population, and use it here to characterize in detail the subtle defects in cell migration caused by ethanol exposure during early development. The challenge was to quantify changes in the in vivo migration of all Sox10:EGFP expressing cells in the visual field of time-lapse movies. To perform this analysis we used an Optical Flow algorithm for motion detection and combined the analysis with a fit to an affine transformation. Through this analysis we detected and quantified significant differences in the cell migrations of Sox10:EGFP positive cranial neural crest populations in ethanol treated versus untreated embryos. Specifically, treatment affected migration by increasing the left-right asymmetry of the migrating cells and by altering the direction of cell movements. Thus, by applying this novel computational analysis, we were able to quantify the movements of populations of cells, allowing us to detect subtle changes in cell behaviors. Because cranial neural crest cells contribute to the formation of the frontal mass these subtle differences may underlie commonly observed facial asymmetries in normal human populations.

  7. Separation of platelets from other blood cells in continuous-flow by dielectrophoresis field-flow-fractionation

    OpenAIRE

    Piacentini, Niccolò; Mernier, Guillaume; Tornay, Raphaël; Renaud, Philippe

    2011-01-01

    We present a microfluidic device capable of separating platelets from other blood cells in continuous flow using dielectrophoresis field-flow-fractionation. The use of hydrodynamic focusing in combination with the application of a dielectrophoretic force allows the separation of platelets from red blood cells due to their size difference. The theoretical cell trajectory has been calculated by numerical simulations of the electrical field and flow speed, and is in agreement with the experiment...

  8. Experimental investigation two phase flow in direct methanol fuel cells

    International Nuclear Information System (INIS)

    Mat, M. D.; Kaplan, Y.; Celik, S.; Oeztural, A.

    2007-01-01

    Direct methanol fuel cells (DMFC) have received many attentions specifically for portable electronic applications since it utilize methanol which is in liquid form in atmospheric condition and high energy density of the methanol. Thus it eliminates the storage problem of hydrogen. It also eliminates humidification requirement of polymeric membrane which is a problem in PEM fuel cells. Some electronic companies introduced DMFC prototypes for portable electronic applications. Presence of carbon dioxide gases due to electrochemical reactions in anode makes the problem a two phase problem. A two phase flow may occur at cathode specifically at high current densities due to the excess water. Presence of gas phase in anode region and liquid phase in cathode region prevents diffusion of fuel and oxygen to the reaction sites thus reduces the performance of the system. Uncontrolled pressure buildup in anode region increases methanol crossover through membrane and adversely effect the performance. Two phase flow in both anode and cathode region is very effective in the performance of DMYC system and a detailed understanding of two phase flow for high performance DMFC systems. Although there are many theoretical and experimental studies available on the DMFC systems in the literature, only few studies consider problem as a two-phase flow problem. In this study, an experimental set up is developed and species distributions on system are measured with a gas chromatograph. System performance characteristics (V-I curves) is measured depending on the process parameters (temperature, fuel ad oxidant flow rates, methanol concentration etc)

  9. Experimental study and comparison of various designs of gas flow fields to PEM fuel cells and cell stack performance

    Directory of Open Access Journals (Sweden)

    Hong eLiu

    2014-01-01

    Full Text Available In this study, a significant number of experimental tests to PEM fuel cells were conducted to investigate the effect of gas flow fields on fuel cell performance. Graphite plates with various flow field or flow channel designs, from literature survey and also novel designs by the authors, were used for the PEM fuel cell assembly. The fabricated fuel cells all have an effective membrane area of 23.5 cm2. The results showed that the serpentine flow channel design is still favorable, giving the best single fuel cell performance amongst all the studied flow channel designs. A novel symmetric serpentine flow field was proposed for relatively large size fuel cell application. Four fuel cell stacks each including four cells were assembled using different designs of serpentine flow channels. The output power performances of fuel cell stacks were compared and the novel symmetric serpentine flow field design is recommended for its very good performance.

  10. JNK2 promotes endothelial cell alignment under flow.

    Directory of Open Access Journals (Sweden)

    Cornelia Hahn

    Full Text Available Endothelial cells in straight, unbranched segments of arteries elongate and align in the direction of flow, a feature which is highly correlated with reduced atherosclerosis in these regions. The mitogen-activated protein kinase c-Jun N-terminal kinase (JNK is activated by flow and is linked to inflammatory gene expression and apoptosis. We previously showed that JNK activation by flow is mediated by integrins and is observed in cells plated on fibronectin but not on collagen or basement membrane proteins. We now show thatJNK2 activation in response to laminar shear stress is biphasic, with an early peak and a later peak. Activated JNK localizes to focal adhesions at the ends of actin stress fibers, correlates with integrin activation and requires integrin binding to the extracellular matrix. Reducing JNK2 activation by siRNA inhibits alignment in response to shear stress. Cells on collagen, where JNK activity is low, align slowly. These data show that an inflammatory pathway facilitates adaptation to laminar flow, thereby revealing an unexpected connection between adaptation and inflammatory pathways.

  11. Three-dimensional numerical study on cell performance and transport phenomena of PEM fuel cells with conventional flow fields

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Jer-Huan [Department of Mechanical Engineering, Northern Taiwan Institute of Science and Technology, Beitou, Taipei 11202 (China); Yan, Wei-Mon; Li, Hung-Yi; Tsai, Wei-Che [Department of Mechatronic Engineering, Huafan University, Shih-Ting, Taipei 22305 (China)

    2008-01-15

    In this paper, a three-dimensional numerical model of the proton exchange membrane fuel cells (PEMFCs) with conventional flow field designs (parallel flow field, Z-type flow field, and serpentine flow field) has been established to investigate the performance and transport phenomena in the PEMFCs. The influences of the flow field designs on the fuel utilization, the water removal, and the cell performance of the PEMFC are studied. The distributions of velocity, oxygen mass fraction, current density, liquid water, and pressure with the convention flow fields are presented. For the conventional flow fields, the cell performance can be enhanced by adding the corner number, increasing the flow channel length, and decreasing the flow channel number. The cell performance of the serpentine flow field is the best, followed by the Z-type flow field and then the parallel flow field. (author)

  12. Modeling of Flow in Nuclear Reactor Fuel Cell Outlet

    Directory of Open Access Journals (Sweden)

    František URBAN

    2010-12-01

    Full Text Available Safe and effective load of nuclear reactor fuel cells demands qualitative and quantitative analysis of relations between coolant temperature in fuel cell outlet temperature measured by thermocouple and middle temperature of coolant in thermocouple plane position. In laboratory at Insitute of thermal power engineering of the Slovak University of Technology in Bratislava was installed an experimental physical fuel cell model of VVER 440 nuclear power plant with V 213 nuclear reactors. Objective of measurements on physical model was temperature and velocity profiles analysis in the fuel cell outlet. In this paper the measured temperature and velocity profiles are compared with the results of CFD simulation of fuel cell physical model coolant flow.

  13. Separation of cancer cells from white blood cells by pinched flow fractionation

    DEFF Research Database (Denmark)

    Jensen, Marie Pødenphant; Ashley, Neil; Koprowska, Kamila

    2015-01-01

    In this paper, the microfluidic size-separation technique pinched flow fractionation (PFF) is used to separate cancer cells from white blood cells (WBCs). The cells are separated at efficiencies above 90% for both cell types. Circulating tumor cells (CTCs) are found in the blood of cancer patients...... and can form new tumors. CTCs are rare cells in blood, but they are important for the understanding of metastasis. There is therefore a high interest in developing a method for the enrichment of CTCs from blood samples, which also enables further analysis of the separated cells. The separation...

  14. Cerebral blood flow mapping in children with sickle cell disease

    International Nuclear Information System (INIS)

    Numaguchi, Y.; Humbert, J.R.; Robinson, A.E.; Lindstrom, W.W.; Gruenauer, L.M.

    1988-01-01

    A cerebral blood flow mapping system was applied to the evaluation of cerebral blood flow (CBF) in 21 patients with sickle cell cerebrovascular disease, by means of a Picker xenon computed tomographic (CT) scanner. Results indicate that (1) xenon CT is a safe and reliable procedure in children with cerebrovascular diseases; (2) CBF in the gray matter of children seems to be higher than in previously reported data obtained with use of isotopes; and (3) regional CBF can be altered significantly by changing the size of the region of interest (ROI). The term regional CBF probably has to be carefully defined in xenon CT flow mapping. Correlation with anatomy by means of CT or magnetic resonance imaging and comparison with the ROI of the contralateral side and/or adjacent sections is important

  15. Rapid flow-induced responses in endothelial cells

    Science.gov (United States)

    Stamatas, G. N.; McIntire, L. V.

    2001-01-01

    Endothelial cells alter their morphology, growth rate, and metabolism in response to fluid shear stress. To study rapid flow-induced responses in the 3D endothelial cell morphology and calcium distribution, coupled fluorescence microscopy with optical sectioning, digital imaging, and numerical deconvolution techniques have been utilized. Results demonstrate that within the first minutes of flow application nuclear calcium is increasing. In the same time frame whole cell height and nuclear height are reduced by about 1 microm. Whole cell height changes may facilitate reduction of shear stress gradients on the luminal surface, whereas nuclear structural changes may be important for modulating endothelial growth rate and metabolism. To study the role of the cytoskeleton in these responses, endothelial cells have been treated with specific disrupters (acrylamide, cytochalasin D, and colchicine) of each of the cytoskeleton elements (intermediate filaments, microfilaments, and microtubules, respectively). None of these compounds had any effect on the shear-induced calcium response. Cytochalasin D and acrylamide did not affect the shear-induced nuclear morphology changes. Colchicine, however, completely abrogated the response, indicating that microtubules may be implicated in force transmission from the plasma membrane to the nucleus. A pedagogical model based on tensegrity theory principles is presented that is consistent with the results on the 3D endothelial morphology.

  16. Immunological profiling of haemodialysis patients and young healthy individuals with implications for clinical regulatory T cell sorting.

    Science.gov (United States)

    Bergström, M; Joly, A-L; Seiron, P; Isringhausen, S; Modig, E; Fellström, B; Andersson, J; Berglund, D

    2015-05-01

    With the increasing interest in clinical trials with regulatory T cells (Tregs), immunological profiling of prospective target groups and standardized procedures for Treg isolation are needed. In this study, flow cytometry was used to assess peripheral blood lymphocyte profiles of young healthy individuals and patients undergoing haemodialysis treatment. Tregs obtained from the former may be used in haematopoietic stem cell transplantation and Tregs from the latter in the prevention of kidney transplant rejection. FOXP3 mRNA expression with accompanying isoform distribution was also assessed by the quantitative reverse transcriptase polymerase chain reaction. Flow-cytometric gating strategies were systematically analysed to optimize the isolation of Tregs. Our findings showed an overall similar immunological profile of both cohorts in spite of great differences in both age and health. Analysis of flow-cytometric gating techniques highlighted the importance of gating for both CD25high and CD127low expression in the isolation of FOXP3-positive cells. This study provides additional insight into the immunological profile of young healthy individuals and uraemic patients as well as in-depth analysis of flow-cytometric gating strategies for Treg isolation, supporting the development of Treg therapy using cells from healthy donors and uraemic patients. © 2015 John Wiley & Sons Ltd.

  17. Ratiometric fluorescence polarization as a cytometric functional parameter: theory and practice

    Energy Technology Data Exchange (ETDEWEB)

    Yishai, Yitzhak; Fixler, Dror; Cohen-Kashi, Meir; Zurgil, Naomi; Deutsch, Mordechai [The Biophysical Interdisciplinary Jerome Schottenstein Center for the Research and the Technology of the Cellome, Department of Physics, Bar-Ilan University, Ramat-Gan 52900 (Israel)

    2003-08-07

    The use of ratiometric fluorescence polarization (RFP) as a functional parameter in monitoring cellular activation is suggested, based on the physical phenomenon of fluorescence polarization dependency on emission wavelengths in multiple (at least binary) solutions. The theoretical basis of this dependency is thoroughly discussed and examined via simulation. For simulation, aimed to imitate a fluorophore-stained cell, real values of the fluorescence spectrum and polarization of different single fluorophore solutions were used. The simulation as well as the experimentally obtained values of RFP indicated the high sensitivity of this measure. Finally, the RFP parameter was utilized as a cytometric measure in three exemplary cellular bioassays. In the first, the apoptotic effect of oxLDL in a human Jurkat FDA-stained T cell line was monitored by RFP. In the second, the interaction between cell surface membrane receptors of human T lymphocyte cells was monitored by RFP measurements as a complementary means to the fluorescence resonance energy transfer (FRET) technique. In the third bioassay, cellular thiol level of FDA- and CMFDA-labelled Jurkat T cells was monitored via RFP.

  18. Flow Cytometry Analysis of Cell Cycle and Specific Cell Synchronization with Butyrate.

    Science.gov (United States)

    Li, Cong-Jun

    2017-01-01

    Synchronized cells have been invaluable in many kinds of cell cycle and cell proliferation studies. Butyrate induces cell cycle arrest and apoptosis in MDBK cells. We explore the possibility of using butyrate-blocked cells to obtain synchronized cells and we characterize the properties of butyrate-induced cell cycle arrest. The site of growth inhibition and cell cycle arrest was analyzed using 5-bromo-2'-deoxyuridine (BrdU) incorporation and flow cytometry analyses. Exposure of MDBK cells to 10 mM butyrate caused growth inhibition and cell cycle arrest in a reversible manner. Butyrate affected the cell cycle at a specific point both immediately after mitosis and at a very early stage of the G1 phase. After release from butyrate arrest, MDBK cells underwent synchronous cycles of DNA synthesis and transited through the S phase. It takes at least 8 h for butyrate-induced G1-synchronized cells to begin the progression into the S phase. One cycle of cell division for MDBK cells is about 20 h. By combining BrdU incorporation and DNA content analysis, not only can the overlapping of different cell populations be eliminated, but the frequency and nature of individual cells that have synthesized DNA can be determined.

  19. Improved Flow-Field Structures for Direct Methanol Fuel Cells

    Energy Technology Data Exchange (ETDEWEB)

    Gurau, Bogdan [Nuvant Systems Inc., Crown Point, IN (United States)

    2013-05-31

    The direct methanol fuel cell (DMFC) is ideal if high energy-density liquid fuels are required. Liquid fuels have advantages over compressed hydrogen including higher energy density and ease of handling. Although state-of-the-art DMFCs exhibit manageable degradation rates, excessive fuel crossover diminishes system energy and power density. Although use of dilute methanol mitigates crossover, the concomitant lowering of the gross fuel energy density (GFED) demands a complex balance-of-plant (BOP) that includes higher flow rates, external exhaust recirculation, etc. An alternative approach is redesign of the fuel delivery system to accommodate concentrated methanol. NuVant Systems Inc. (NuVant) will maximize the GFED by design and assembly of a DMFC that uses near neat methanol. The approach is to tune the diffusion of highly concentrated methanol (to the anode catalytic layer) to the back-diffusion of water formed at the cathode (i.e. in situ generation of dilute methanol at the anode layer). Crossover will be minimized without compromising the GFED by innovative integration of the anode flow-field and the diffusion layer. The integrated flow-field-diffusion-layers (IFDLs) will widen the current and potential DMFC operating ranges and enable the use of cathodes optimized for hydrogen-air fuel cells.

  20. High-resolution Antibody Array Analysis of Childhood Acute Leukemia Cells

    Czech Academy of Sciences Publication Activity Database

    Kanderová, V.; Kuzilkova, D.; Stuchlý, J.; Vašková, M.; Brdička, Tomáš; Fišer, K.; Hrušák, O.; Lund-Johansen, F.; Kalina, T.

    2016-01-01

    Roč. 15, č. 4 (2016), s. 1246-1261 ISSN 1535-9476 R&D Projects: GA MŠk 2B06064 Institutional support: RVO:68378050 Keywords : acute lymphoblastic-leukemia * acute promyelocytic leukemia * cytometric immunobead assay * caspase-dependent cleavage * acute myeloid-leukemia * gene-expression * fusion proteins * flow-cytometry * pcr data * b-cells Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 6.540, year: 2016

  1. New high temperature gas flow cell developed at ISIS

    Science.gov (United States)

    Haynes, R.; Norberg, S. T.; Eriksson, S. G.; Chowdhury, M. A. H.; Goodway, C. M.; Howells, G. D.; Kirichek, O.; Hull, S.

    2010-11-01

    A flow-through quartz gas cell, together with a gas flow control and monitoring system, has been designed and constructed at ISIS. This equipment allows neutron powder diffraction data to be collected on samples at temperatures up to around 1300 K when exposed to user chosen mixtures of O2, Ar, CO2, and CO. By exploiting the sensitivity of neutrons to the presence of light atoms such as oxygen, it is possible to probe the crystal structure of oxide materials as a function of oxygen partial pressures down to log10p(O2) of about -20. The resultant structural information can then be correlated with the bulk properties of the materials, whose research and technological interests lie in fields such as energy production, storage materials, catalysis, and earth science.

  2. New high temperature gas flow cell developed at ISIS

    International Nuclear Information System (INIS)

    Haynes, R; Norberg, S T; Eriksson, S G; Chowdhury, M A H; Goodway, C M; Howells, G D; Kirichek, O; Hull, S

    2010-01-01

    A flow-through quartz gas cell, together with a gas flow control and monitoring system, has been designed and constructed at ISIS. This equipment allows neutron powder diffraction data to be collected on samples at temperatures up to around 1300 K when exposed to user chosen mixtures of O 2 , Ar, CO 2 , and CO. By exploiting the sensitivity of neutrons to the presence of light atoms such as oxygen, it is possible to probe the crystal structure of oxide materials as a function of oxygen partial pressures down to log 10 p(O 2 ) of about -20. The resultant structural information can then be correlated with the bulk properties of the materials, whose research and technological interests lie in fields such as energy production, storage materials, catalysis, and earth science.

  3. Flow cytometry and monoclonal antibodies identify normal liver cell populations antigenically related to oval cells.

    Science.gov (United States)

    Agelli, M; Halay, E D

    1995-01-01

    Oval cells, a non-parenchymal cell population induced to rapidly proliferate in animals treated with carcinogens, are thought to be related to the hypothesized liver stem cells. In normal liver there are poorly defined cells antigenically related to oval cells. These oval cell antigen positive (OCAP) cells present in normal animals are thought to include hepatocyte and bile duct cell precursors. To isolate them, we modified the existing protocols designed for oval cells and used it on normal neonatal rat livers. Using flow cytometry, the percentage of normal liver OCAP-cells varied with the monoclonal antibody (MoAb) to the different oval cell membrane markers used: 12% (MoAb 18.2), 23% (MoAb 270.38), 27% (MoAb 18.11), 31% (MoAb 18.13), and 37% (MoAb 374.3). Macrophages consisted 10% of the cells (MoAb MCA 275); hepatocytes were essentially absent ( < 1%, MoAb 236.4). Our results demonstrate that is possible to obtain significant numbers of normal cells antigenically related to oval cells and that using different MoAbs, different cell populations can be sorted for use in experimental studies testing liver progenitor cell hypothesis.

  4. Cytometric analysis of DNA changes induced by sulfur mustard

    Energy Technology Data Exchange (ETDEWEB)

    Smith, W.J.; Sanders, K.M.; Ruddle, S.E.; Gross, C.L.

    1993-05-13

    Sulfur mustard is an alkylating agent which causes severe, potentially debilitating blisters following cutaneous exposure. Its mechanism of pathogenesis is unknown and no antidote exists to prevent its pathology. The biochemical basis of sulfur mustard's vesicating activity has been hypothesized to be a cascade of events beginning with alkylation of DNA. Using human cells in culture, we have assessed the effects of sulfur mustard on cell cycle activity using flow cytometry with propidium iodide. Two distinct patterns emerged, a Gl/S interface block at concentrations equivalent to vesicating doses (>50-micronM) and a G2 block at 10-fold lower concentrations. In addition, noticeable increases in amount of dye uptake were observed at 4 and 24 hours after sulfur mustard exposure. These increases are believed to be related to DNA repair activities and can be prevented by treatment of the cells with niacinamide, which inhibits DNA repair. Other drugs which provide alternate alkylating sites or inhibit cell cycle progression were shown to lower the cytotoxicity of sulfur mustard and to protect against its direct DNA damaging effects.

  5. Image cytometric evaluation of nuclear texture features and DNA content of the reticular form of oral lichen planus.

    Science.gov (United States)

    Rode, Matjaz; Flezar, Margareta Strojan; Kogoj-Rode, Mirela; Us-Krasovec, Marija

    2006-10-01

    To analyze image cytometric chromatin changes reflected in nuclear texture features and DNA ploidy of oral lichen planus in relation to the normal buccal mucosa and buccal mucosa expressing malignancy-associated changes in cancer patients. Twenty-eight patients with the reticular form of oral lichen planus, with a follow-up period of 25 years, 50 healthy controls and 50 lung cancer patients were included in the study. Scrapings of buccal mucosa were suspended in transport medium. Monolayer filter preparations were Feulgen-thionin stained. Image cytometric analysis was performed by Cyto-Savant. All oral lichen planus specimens in our study were diploid. In univariate analysis, differences between the normal buccal mucosa and oral lichen planus were found in several nuclear texture features, which gave an 80% correct classification rate in multivariate analysis. In the second part of the study, the classifier that recognizes malignancy-associated changes on the buccal mucosa of patients with lung cancer correctly recognized > 80% of oral lichen planus samples as normal buccal mucosa. Our results indicate that chromatin changes in oral lichen planus exist compared to normal cells; however, the chromatin structure of the reticular form of oral lichen planus does not express malignancy-associated changes and is more similar to normal squamous cells.

  6. Hormonal protection of spermatogenic stem cells during irradiation

    International Nuclear Information System (INIS)

    Kroonenburgh, M.J.P.G. van.

    1986-01-01

    In this thesis it is examined if by hormonal suppression of spermatogenesis the disadvantageous side-effects of radiation therapy on the gonads can be reduced. Therefore a rat model was investigated, where hormonal suppression of spermatogenesis during irradiation was achieved and stem cell survival was measured. Attention was focussed on the stem cell, because this cell is primarily responsible for the late effects of radiation on fertility. Flow cytometrical and histological techniques were used as parameters for measuring stem cell survival. Serum concentrations of FSH, LH and testosterone were measured to evaluate the hormonal suppression. (Auth.)

  7. Functional characterization of neotropical snakes peripheral blood leukocytes subsets: Linking flow cytometry cell features, microscopy images and serum corticosterone levels.

    Science.gov (United States)

    de Carvalho, Marcelo Pires Nogueira; Queiroz-Hazarbassanov, Nicolle Gilda Teixeira; de Oliveira Massoco, Cristina; Sant'Anna, Sávio Stefanini; Lourenço, Mariana Mathias; Levin, Gabriel; Sogayar, Mari Cleide; Grego, Kathleen Fernandes; Catão-Dias, José Luiz

    2017-09-01

    Reptiles are the unique ectothermic amniotes, providing the key link between ectothermic anamniotes fish and amphibians, and endothermic birds and mammals; becoming an important group to study with the aim of providing significant knowledge into the evolutionary history of vertebrate immunity. Classification systems for reptiles' leukocytes have been described by their appearance rather than function, being still inconsistent. With the advent of modern techniques and the establishment of analytical protocols for snakes' blood by flow cytometry, we bring a qualitative and quantitative assessment of innate activities presented by snakes' peripheral blood leukocytes, thereby linking flow cytometric features with fluorescent and light microscopy images. Moreover, since corticosterone is an important immunomodulator in reptiles, hormone levels of all blood samples were measured. We provide novel and additional information which should contribute to better understanding of the development of the immune system of reptiles and vertebrates. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Electrochemical and flow characterization of a direct methanol fuel cell

    Science.gov (United States)

    Lu, G. Q.; Wang, C. Y.

    Two-phase phenomena, i.e. bubble flow in the anode and water flooding in the cathode, are critical to design of high-performance direct methanol fuel cells (DMFC). A 5 cm 2 transparent DMFC has been developed to visualize these phenomena in situ. Two types of membrane-electrode assembly (MEA) based on Nafion ® 112 were used to investigate effects of backing pore structure and wettability on cell polarization characteristics and two-phase flow dynamics. One employed carbon paper backing material and the other carbon cloth. Experiments were performed under conditions of various methanol feed concentrations. The transparent fuel cell was shown to reach a peak power of 93 mW/cm 2 at 0.3 V, using Toray carbon-paper based MEA under 2 M methanol solution preheated at 85 °C. For the hydrophobic carbon paper backing, it was observed that CO 2 bubbles nucleate at certain locations and form large and discrete bubble slugs in the channel. For the hydrophilic carbon cloth backing, it was shown that bubbles are produced more uniformly and of smaller size. It is thus shown that the anode backing layer of uniform pore size and more hydrophilicity is preferred for gas management in the anode. Flow visualization of water flooding on the cathode side of DMFC has also been carried out. It is shown that liquid droplets appear more easily on the surface of carbon paper due to its reduced hydrophobicity at elevated temperature. For the single-side ELAT carbon cloth, liquid droplets tend to form in the corner between the current collecting rib and GDL since ELAT is highly hydrophobic and the rib (stainless steel) surface is hydrophilic.

  9. Proteomic analysis of barley cell nuclei purified by flow sorting

    Czech Academy of Sciences Publication Activity Database

    Petrovská, Beáta; Jeřábková, Hana; Chamrád, I.; Vrána, Jan; Lenobel, R.; Uřinovská, J.; Šebela, M.; Doležel, Jaroslav

    2014-01-01

    Roč. 143, 1-3 (2014), s. 78-86 ISSN 1424-8581 R&D Projects: GA ČR GBP501/12/G090; GA ČR(CZ) GA14-28443S; GA MŠk(CZ) LO1204 Institutional support: RVO:61389030 Keywords : Cell cycle * Chromatin * Flow cytometry Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 1.561, year: 2014 http://gateway.isiknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=Alerting&SrcApp=Alerting&DestApp=MEDLINE&DestLinkType=FullRecord&UT=25059295

  10. Numerical study of cell performance and local transport phenomena in PEM fuel cells with various flow channel area ratios

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xiao-Dong [Department of Thermal Engineering, School of Mechanical Engineering, University of Science and Technology Beijing, Beijing 100083 (China); Duan, Yuan-Yuan [Key Laboratory of Thermal Science and Power Engineering of MOE, Tsinghua University, Beijing 100084 (China); Yan, Wei-Mon [Department of Mechatronic Engineering, Huafan University, Shih-Ting 22305 (China)

    2007-10-11

    Three-dimensional models of proton exchange membrane fuel cells (PEMFCs) with parallel and interdigitated flow channel designs were developed including the effects of liquid water formation on the reactant gas transport. The models were used to investigate the effects of the flow channel area ratio and the cathode flow rate on the cell performance and local transport characteristics. The results reveal that at high operating voltages, the cell performance is independent of the flow channel designs and operating parameters, while at low operating voltages, both significantly affect cell performance. For the parallel flow channel design, as the flow channel area ratio increases the cell performance improves because fuel is transported into the diffusion layer and the catalyst layer mainly by diffusion. A larger flow channel area ratio increases the contact area between the fuel and the diffusion layer, which allows more fuel to directly diffuse into the porous layers to participate in the electrochemical reaction which enhances the reaction rates. For the interdigitated flow channel design, the baffle forces more fuel to enter the cell and participate in the electrochemical reaction, so the flow channel area ratio has less effect. Forced convection not only increases the fuel transport rates but also enhances the liquid water removal, thus interdigitated flow channel design has higher performance than the parallel flow channel design. The optimal performance for the interdigitated flow channel design occurs for a flow channel area ratio of 0.4. The cell performance also improves as the cathode flow rate increases. The effects of the flow channel area ratio and the cathode flow rate on cell performance are analyzed based on the local current densities, oxygen flow rates and liquid water concentrations inside the cell. (author)

  11. DNA flow cytometry of human spermatozoa: consistent stoichiometric staining of sperm DNA using a novel decondensation protocol.

    Science.gov (United States)

    Kovács, Tamás; Békési, Gyöngyi; Fábián, Akos; Rákosy, Zsuzsa; Horváth, Gábor; Mátyus, László; Balázs, Margit; Jenei, Attila

    2008-10-01

    Rapid flow cytometric measurement of the frequency of aneuploid human sperms is in increasing demand but development of an exploitable method is hindered by difficulties of stoichiometric staining of sperm DNA. An aggressive decondensation protocol is needed after which cell integrity still remains intact. We used flow cytometry to examine the effect of lithium diiodosalicylate (LIS, chaotropic agent) on fluorescence intensity of propidium iodide-treated human spermatozoa from 10 normozoospermic men. When flow cytometric identification of diploid spermatozoa was achieved, validation was performed after sorting by three-color FISH. In contrast with the extremely variable histograms of nondecondensed sperms, consistent identification of haploid and diploid spermatozoa was possible if samples were decondensed with LIS prior to flow cytometry. A 76-fold enrichment of diploid sperms was observed in the sorted fractions by FISH. A significant correlation was found between the proportion of sorted cells and of diploid sperms by FISH. Application of LIS during the preparation of sperm for flow cytometry appears to ensure the stoichiometric staining of sperm DNA, making quantification of aneuploid sperm percentage possible. To our knowledge this is the first report in terms of separating spermatozoa with confirmedly abnormal chromosomal content. High correlation between the proportion of cells identified as having double DNA content by flow cytometry and diploid sperm by FISH allows rapid calculation of diploidy rate. Copyright 2008 International Society for Advancement of Cytometry.

  12. Modeling two-phase flow in three-dimensional complex flow-fields of proton exchange membrane fuel cells

    Science.gov (United States)

    Kim, Jinyong; Luo, Gang; Wang, Chao-Yang

    2017-10-01

    3D fine-mesh flow-fields recently developed by Toyota Mirai improved water management and mass transport in proton exchange membrane (PEM) fuel cell stacks, suggesting their potential value for robust and high-power PEM fuel cell stack performance. In such complex flow-fields, Forchheimer's inertial effect is dominant at high current density. In this work, a two-phase flow model of 3D complex flow-fields of PEMFCs is developed by accounting for Forchheimer's inertial effect, for the first time, to elucidate the underlying mechanism of liquid water behavior and mass transport inside 3D complex flow-fields and their adjacent gas diffusion layers (GDL). It is found that Forchheimer's inertial effect enhances liquid water removal from flow-fields and adds additional flow resistance around baffles, which improves interfacial liquid water and mass transport. As a result, substantial improvements in high current density cell performance and operational stability are expected in PEMFCs with 3D complex flow-fields, compared to PEMFCs with conventional flow-fields. Higher current density operation required to further reduce PEMFC stack cost per kW in the future will necessitate optimizing complex flow-field designs using the present model, in order to efficiently remove a large amount of product water and hence minimize the mass transport voltage loss.

  13. Simplified flow cytometric assay to detect minimal residual disease in childhood with acute lymphoblastic leukemia Detecção de doença residual mínima em crianças com leucemia linfoblástica aguda por citometria de fluxo

    Directory of Open Access Journals (Sweden)

    Elizabete Delbuono

    2008-08-01

    Full Text Available The detection of minimal residual disease (MRD is an important prognostic factor in childhood acute lymphoblastic leukemia (ALL providing crucial information on the response to treatment and risk of relapse. However, the high cost of these techniques restricts their use in countries with limited resources. Thus, we prospectively studied the use of flow cytometry (FC with a simplified 3-color assay and a limited antibody panel to detect MRD in the bone marrow (BM and peripheral blood (PB of children with ALL. BM and PB samples from 40 children with ALL were analyzed on days (d 14 and 28 during induction and in weeks 24-30 of maintenance therapy. Detectable MRD was defined as > 0.01% cells expressing the aberrant immunophenotype as characterized at diagnosis among total events in the sample. A total of 87% of the patients had an aberrant immunophenotype at diagnosis. On d14, 56% of the BM and 43% of the PB samples had detectable MRD. On d28, this decreased to 45% and 31%, respectively. The percentage of cells with the aberrant phenotype was similar in both BM and PB in T-ALL but about 10 times higher in the BM of patients with B-cell-precursor ALL. Moreover, MRD was detected in the BM of patients in complete morphological remission (44% on d14 and 39% on d28. MRD was not significantly associated to gender, age, initial white blood cell count or cell lineage. This FC assay is feasible, affordable and readily applicable to detect MRD in centers with limited resources.A detecção de doença residual mínima (DRM é um importante fator prognóstico na leucemia linfóide aguda (LLA infantil e fornece informações sobre a resposta ao tratamento e o risco de recaída. Entretanto, os altos custos das técnicas utilizadas limitam seu uso nos países em desenvolvimento. Desta forma, realizamos um estudo prospectivo para avaliar a citometria de fluxo (CF, utilizando três fluorescências e um painel limitado de anticorpos monoclonais, como método de detec

  14. The Analysis of Cell Cycle, Proliferation, and Asymmetric Cell Division by Imaging Flow Cytometry.

    Science.gov (United States)

    Filby, Andrew; Day, William; Purewal, Sukhveer; Martinez-Martin, Nuria

    2016-01-01

    Measuring cellular DNA content by conventional flow cytometry (CFC) and fluorescent DNA-binding dyes is a highly robust method for analysing cell cycle distributions within heterogeneous populations. However, any conclusions drawn from single-parameter DNA analysis alone can often be confounded by the asynchronous nature of cell proliferation. We have shown that by combining fluorescent DNA stains with proliferation tracking dyes and antigenic staining for mitotic cells one can elucidate the division history and cell cycle position of any cell within an asynchronously dividing population. Furthermore if one applies this panel to an imaging flow cytometry (IFC) system then the spatial information allows resolution of the four main mitotic phases and the ability to study molecular distributions within these populations. We have employed such an approach to study the prevalence of asymmetric cell division (ACD) within activated immune cells by measuring the distribution of key fate determining molecules across the plane of cytokinesis in a high-throughput, objective, and internally controlled manner. Moreover the ability to perform high-resolution, temporal dissection of the cell division process lends itself perfectly to investigating the influence chemotherapeutic agents exert on the proliferative capacity of transformed cell lines. Here we describe the method in detail and its application to both ACD and general cell cycle analysis.

  15. Cerebral blood flow in sickle cell cerebrovascular disease

    International Nuclear Information System (INIS)

    Huttenlocher, P.R.; Moohr, J.W.; Johns, L.; Brown, F.D.

    1984-01-01

    Cerebral blood flow (CBF) has been studied by the xenon-133 ( 133 Xe) inhalation method in 16 children with suspected sickle cell cerebrovascular disease. Abnormalities consisting of decreases in total, hemispheral, or regional CBF were found in 17 of 26 studies. Eleven studies performed immediately after stroke, transient ischemic attack, or depression of state of alertness showed abnormalities. In addition to confirming regional cerebrovascular insufficiency in children with stroke due to major cerebral artery occlusion, the method detected diffuse decrease in CBF in children with stupor, coma, and seizures who had normal angiographic findings. In contrast, six of seven studies obtained after exchange transfusion or during maintenance on hypertransfusion therapy showed normal findings. The difference between results in patients with acute neurologic disturbances and those receiving transfusion therapy was statistically significant (P less than .005). The data indicate that the 133 Xe method reliably demonstrates cerebrovascular impairment in sickle cell disease. They also suggest that CBF changes in patients with sickle cell disease can be reversed by exchange transfusion and by hypertransfusion therapy. The 133 Xe CBF method may be useful for following up children with sickle cell disease who are at high risk for recurrent stroke

  16. 3D-printed and CNC milled flow-cells for chemiluminescence detection.

    Science.gov (United States)

    Spilstead, Kara B; Learey, Jessica J; Doeven, Egan H; Barbante, Gregory J; Mohr, Stephan; Barnett, Neil W; Terry, Jessica M; Hall, Robynne M; Francis, Paul S

    2014-08-01

    Herein we explore modern fabrication techniques for the development of chemiluminescence detection flow-cells with features not attainable using the traditional coiled tubing approach. This includes the first 3D-printed chemiluminescence flow-cells, and a milled flow-cell designed to split the analyte stream into two separate detection zones within the same polymer chip. The flow-cells are compared to conventional detection systems using flow injection analysis (FIA) and high performance liquid chromatography (HPLC), with the fast chemiluminescence reactions of an acidic potassium permanganate reagent with morphine and a series of adrenergic phenolic amines. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Methods for studying biofilm formation: flow cells and confocal laser scanning microscopy

    DEFF Research Database (Denmark)

    Tolker-Nielsen, Tim; Sternberg, Claus

    2014-01-01

    In this chapter methods for growing and analyzing biofilms under hydrodynamic conditions in flow cells are described. Use of flow cells allows for direct microscopic investigation of biofilm formation. The flow in these chambers is essentially laminar, which means that the biofilms can be grown...... under highly controlled conditions, and that perturbations such as addition of antibiotics or change of the growth medium can be done efficiently at a defined time point. The protocol includes construction of the flow cell and the bubble trap, assembly and sterilization of the flow cell system...

  18. Comparison of plateletpheresis on three continuous flow cell separators

    Directory of Open Access Journals (Sweden)

    Tendulkar Anita

    2009-01-01

    Full Text Available Introduction: Platelet concentrate (PC remains one of the most important support measures in thrombocytopenic patients. An efficient cell separator is a prerequisite for an optimally functioning apheresis setup. Donor blood count may undergo a temporary reduction after the procedure. Aim: The aim was to find the extent of reduction in donor blood count (hemoglobin, hematocrit, white blood cell, and platelet after plateletpheresis and to evaluate the cell separator for collection efficiency, processing time, and leukoreduction. Study Design and Methods: Two hundred and thirty seven procedures performed on the Amicus (N = 121, Fenwal CS-3000 Plus (N = 50 and Cobe spectra (N = 66 in a one year period were evaluated. The procedures performed on the continuous flow centrifugation (CFC cell separators and donor blood counts (pre and post donation done were included in the study. Results: The percent reduction in hemoglobin (HB, hematocrit (HCT, white blood cell (WBC and platelet count ((PLT ct was 2.9, 3.1, 9, 30.7 (Mean, N = 237 respectively after the procedure. The post donation PLT ct reduced to < 100x109/L (range 80-100 in five donors (N = 5/237, Amicus. The pre donation PLT ct in them was 150-200x109/L. Collection efficiency (percent of Amicus (79.3 was better as compared to the other two machines (CS: 62.5, Cobe: 57.5. PC collected on Cobe spectra had < 1x106 WBC. The donor pre donation PLT levels had a positive correlation to the product PLT yield (r = 0.30, P = 0.000. Conclusion: Monitoring donor blood counts helps to avoid pheresis induced adverse events. A cautious approach is necessary in donors whose pre donation PLT ct is 150-200x109/L. The main variable in PLT yield is donor PLT ct (pre donation. High collection efficiency is a direct measure of an optimally functioning cell separator.

  19. Use of Multicolor Flow Cytometry for Isolation of Specific Cell Populations Deriving from Differentiated Human Embryonic Stem Cells

    NARCIS (Netherlands)

    Mengarelli, Isabella; Fryga, Andrew; Barberi, Tiziano

    2016-01-01

    Flow Cytometry-Sorting (FCM-Sorting) is a technique commonly used to identify and isolate specific types of cells from a heterogeneous population of live cells. Here we describe a multicolor flow cytometry technique that uses five distinct cell surface antigens to isolate four live populations with

  20. Detection of circulating breast cancer cells using photoacoustic flow cytometry

    Science.gov (United States)

    Bhattacharyya, Kiran

    According to the American Cancer Society, more than 200,000 new cases of breast cancer are expected to be diagnosed this year. Moreover, about 40,000 women died from breast cancer last year alone. As breast cancer progresses in an individual, it can transform from a localized state to a metastatic one with multiple tumors distributed through the body, not necessarily contained within the breast. Metastasis is the spread of cancer through the body by circulating tumor cells (CTCs) which can be found in the blood and lymph of the diagnosed patient. Diagnosis of a metastatic state by the discovery of a secondary tumor can often come too late and hence, significantly reduce the patient's chance of survival. There is a current need for a CTC detection method which would diagnose metastasis before the secondary tumor occurs or reaches a size resolvable by current imaging systems. Since earlier detection would improve prognosis, this study proposes a method of labeling of breast cancer cells for detection with a photoacoustic flow cytometry system as a model for CTC detection in human blood. Gold nanoparticles and fluorescent polystyrene nanoparticles are proposed as contrast agents for T47D, the breast cancer cell line of choice. The labeling, photoacoustic detection limit, and sensitivity are first characterized and then applied to a study to show detection from human blood.

  1. Identifying Cell Populations in Flow Cytometry Data Using Phenotypic Signatures.

    Science.gov (United States)

    Pouyan, Maziyar Baran; Nourani, Mehrdad

    2017-01-01

    Single-cell flow cytometry is a technology that measures the expression of several cellular markers simultaneously for a large number of cells. Identification of homogeneous cell populations, currently done by manual biaxial gating, is highly subjective and time consuming. To overcome the shortcomings of manual gating, automatic algorithms have been proposed. However, the performance of these methods highly depends on the shape of populations and the dimension of the data. In this paper, we have developed a time-efficient method that accurately identifies cellular populations. This is done based on a novel technique that estimates the initial number of clusters in high dimension and identifies the final clusters by merging clusters using their phenotypic signatures in low dimension. The proposed method is called SigClust. We have applied SigClust to four public datasets and compared it with five well known methods in the field. The results are promising and indicate higher performance and accuracy compared to similar approaches reported in literature.

  2. Supercontinuum white light lasers for flow cytometry.

    Science.gov (United States)

    Telford, William G; Subach, Fedor V; Verkhusha, Vladislav V

    2009-05-01

    Excitation of fluorescent probes for flow cytometry has traditionally been limited to a few discrete laser lines, an inherent limitation in our ability to excite the vast array of fluorescent probes available for cellular analysis. In this report, we have used a supercontinuum (SC) white light laser as an excitation source for flow cytometry. By selectively filtering the wavelength of interest, almost any laser wavelength in the visible spectrum can be separated and used for flow cytometric analysis. The white light lasers used in this study were integrated into a commercial flow cytometry platform, and a series of high-transmission bandpass filters used to select wavelength ranges from the blue (approximately 480 nm) to the long red (>700 nm). Cells labeled with a variety of fluorescent probes or expressing fluorescent proteins were then analyzed, in comparison with traditional lasers emitting at wavelengths similar to the filtered SC source. Based on a standard sensitivity metric, the white light laser bandwidths produced similar excitation levels to traditional lasers for a wide variety of fluorescent probes and expressible proteins. Sensitivity assessment using fluorescent bead arrays confirmed that the SC laser and traditional sources resulted in similar levels of detection sensitivity. Supercontinuum white light laser sources therefore have the potential to remove a significant barrier in flow cytometric analysis, namely the limitation of excitation wavelengths. Almost any visible wavelength range can be made available for excitation, allowing access to virtually any fluorescent probe, and permitting "fine-tuning" of excitation wavelength to particular probes. (c) 2008 International Society for Advancement of Cytometry.

  3. An alternative pathway for signal flow from rod photoreceptors to ganglion cells in mammalian retina.

    OpenAIRE

    DeVries, S H; Baylor, D A

    1995-01-01

    Rod signals in the mammalian retina are thought to reach ganglion cells over the circuit rod-->rod depolarizing bipolar cell-->AII amacrine cell-->cone bipolar cells-->ganglion cells. A possible alternative pathway involves gap junctions linking the rods and cones, the circuit being rod-->cone-->cone bipolar cells-->ganglion cells. It is not clear whether this second pathway indeed relays rod signals to ganglion cells. We studied signal flow in the isolated rabbit retina with a multielectrode...

  4. Flow field bipolar plates in a proton exchange membrane fuel cell: Analysis & modeling

    International Nuclear Information System (INIS)

    Kahraman, Huseyin; Orhan, Mehmet F.

    2017-01-01

    Highlights: • Covers a comprehensive review of available flow field channel configurations. • Examines the main design considerations and limitations for a flow field network. • Explores the common materials and material properties used for flow field plates. • Presents a case study of step-by-step modeling for an optimum flow field design. - Abstract: This study investigates flow fields and flow field plates (bipolar plates) in proton exchange membrane fuel cells. In this regard, the main design considerations and limitations for a flow field network have been examined, along with a comprehensive review of currently available flow field channel configurations. Also, the common materials and material properties used for flow field plates have been explored. Furthermore, a case study of step-by-step modeling for an optimum flow field design has been presented in-details. Finally, a parametric study has been conducted with respect to many design and performance parameters in a flow field plate.

  5. Clonal dominance between subpopulations of mixed small cell lung cancer xenografts implanted ectopically in nude mice

    DEFF Research Database (Denmark)

    Aabo, K; Vindeløv, L L; Spang-Thomsen, M

    1995-01-01

    in vitro growth of two sets of small cell lung cancer (SCLC) subpopulations (54A, 54B and NYH, NYH2). The tumour cell lines differed in cellular DNA content enabling flow cytometric DNA analysis (FCM) to be used to monitor changes in the fractional composition of the mixed cell populations. The progeny...... clone 54B was found to dominate the parent 54A clone when grown as mixed subcutaneous xenografts in nude mice, whereas no dominance was exerted during in vitro growth. The in vivo dominance could not be explained by differences in growth kinetics between the two tumour cell lines, and the interaction...

  6. Effects of flow-induced shear stress on limbal epithelial stem cell growth and enrichment.

    Directory of Open Access Journals (Sweden)

    Yun Gyeong Kang

    Full Text Available The roles of limbal epithelial stem cells (LESCs are widely recognized, but for these cells to be utilized in basic research and potential clinical applications, researchers must be able to efficiently isolate them and subsequently maintain their stemness in vitro. We aimed to develop a biomimetic environment for LESCs involving cells from their in vivo niche and the principle of flow-induced shear stress, and to subsequently demonstrate the potential of this novel paradigm. LESCs, together with neighboring cells, were isolated from the minced limbal tissues of rabbits. At days 8 and 9 of culture, the cells were exposed to a steady flow or intermittent flow for 2 h per day in a custom-designed bioreactor. The responses of LESCs and epithelial cells were assessed at days 12 and 14. LESCs and epithelial cells responded to both types of flow. Proliferation of LESCs, as assessed using a BrdU assay, was increased to a greater extent under steady flow conditions. Holoclones were found under intermittent flow, indicating that differentiation into transient amplifying cells had occurred. Immunofluorescent staining of Bmi-1 suggested that steady flow has a positive effect on the maintenance of stemness. This finding was confirmed by real-time PCR. Notch-1 and p63 were more sensitive to intermittent flow, but this effect was transient. K3 and K12 expression, indicative of differentiation of LESCs into epithelial cells, was induced by flow and lasted longer under intermittent flow conditions. In summary, culture of LESCs in a bioreactor under a steady flow paradigm, rather than one of intermittent flow, is beneficial for both increasing proliferation and maintaining stemness. Conversely, intermittent flow appears to induce differentiation of LESCs. This novel experimental method introduces micro-mechanical stimuli to traditional culture techniques, and has potential for regulating the proliferation and differentiation of LESCs in vitro, thereby

  7. Effects of flow-induced shear stress on limbal epithelial stem cell growth and enrichment.

    Science.gov (United States)

    Kang, Yun Gyeong; Shin, Ji Won; Park, So Hee; Oh, Min-Jae; Park, Hyo Soon; Shin, Jung-Woog; Kim, Su-Hyang

    2014-01-01

    The roles of limbal epithelial stem cells (LESCs) are widely recognized, but for these cells to be utilized in basic research and potential clinical applications, researchers must be able to efficiently isolate them and subsequently maintain their stemness in vitro. We aimed to develop a biomimetic environment for LESCs involving cells from their in vivo niche and the principle of flow-induced shear stress, and to subsequently demonstrate the potential of this novel paradigm. LESCs, together with neighboring cells, were isolated from the minced limbal tissues of rabbits. At days 8 and 9 of culture, the cells were exposed to a steady flow or intermittent flow for 2 h per day in a custom-designed bioreactor. The responses of LESCs and epithelial cells were assessed at days 12 and 14. LESCs and epithelial cells responded to both types of flow. Proliferation of LESCs, as assessed using a BrdU assay, was increased to a greater extent under steady flow conditions. Holoclones were found under intermittent flow, indicating that differentiation into transient amplifying cells had occurred. Immunofluorescent staining of Bmi-1 suggested that steady flow has a positive effect on the maintenance of stemness. This finding was confirmed by real-time PCR. Notch-1 and p63 were more sensitive to intermittent flow, but this effect was transient. K3 and K12 expression, indicative of differentiation of LESCs into epithelial cells, was induced by flow and lasted longer under intermittent flow conditions. In summary, culture of LESCs in a bioreactor under a steady flow paradigm, rather than one of intermittent flow, is beneficial for both increasing proliferation and maintaining stemness. Conversely, intermittent flow appears to induce differentiation of LESCs. This novel experimental method introduces micro-mechanical stimuli to traditional culture techniques, and has potential for regulating the proliferation and differentiation of LESCs in vitro, thereby facilitating research in this

  8. Flow manipulation and cell immobilization for biochemical applications using thermally responsive fluids.

    Science.gov (United States)

    Haraksingh Thilsted, Anil; Bazargan, Vahid; Piggott, Nina; Measday, Vivien; Stoeber, Boris

    2012-01-01

    A flow redirection and single cell immobilization method in a microfluidic chip is presented. Microheaters generated localized heating and induced poly(N-isopropylacrylamide) phase transition, creating a hydrogel that blocked a channel or immobilized a single cell. The heaters were activated in sets to redirect flow and exchange the fluid in which an immobilized cell was immersed. A yeast cell was immobilized in hydrogel and a 4',6-diamidino-2-phenylindole (DAPI) fluorescent stain was introduced using flow redirection. DAPI diffused through the hydrogel and fluorescently labelled the yeast DNA, demonstrating in situ single cell biochemistry by means of immobilization and fluid exchange.

  9. In situ spatiotemporal mapping of flow fields around seeded stem cells at the subcellular length scale.

    Directory of Open Access Journals (Sweden)

    Min Jae Song

    2010-09-01

    Full Text Available A major hurdle to understanding and exploiting interactions between the stem cell and its environment is the lack of a tool for precise delivery of mechanical cues concomitant to observing sub-cellular adaptation of structure. These studies demonstrate the use of microscale particle image velocimetry (μ-PIV for in situ spatiotemporal mapping of flow fields around mesenchymal stem cells, i.e. murine embryonic multipotent cell line C3H10T1/2, at the subcellular length scale, providing a tool for real time observation and analysis of stem cell adaptation to the prevailing mechanical milieu. In the absence of cells, computational fluid dynamics (CFD predicts flow regimes within 12% of μ-PIV measures, achieving the technical specifications of the chamber and the flow rates necessary to deliver target shear stresses at a particular height from the base of the flow chamber. However, our μ-PIV studies show that the presence of cells per se as well as the density at which cells are seeded significantly influences local flow fields. Furthermore, for any given cell or cell seeding density, flow regimes vary significantly along the vertical profile of the cell. Hence, the mechanical milieu of the stem cell exposed to shape changing shear stresses, induced by fluid drag, varies with respect to proximity of surrounding cells as well as with respect to apical height. The current study addresses a previously unmet need to predict and observe both flow regimes as well as mechanoadaptation of cells in flow chambers designed to deliver precisely controlled mechanical signals to live cells. An understanding of interactions and adaptation in response to forces at the interface between the surface of the cell and its immediate local environment may be key for de novo engineering of functional tissues from stem cell templates as well as for unraveling the mechanisms underlying multiscale development, growth and adaptation of organisms.

  10. Application of two-phase flow for cooling of hybrid microchannel PV cells: A comparative study

    International Nuclear Information System (INIS)

    Valeh-e-Sheyda, Peyvand; Rahimi, Masoud; Karimi, Ebrahim; Asadi, Masomeh

    2013-01-01

    Highlights: ► Showing cooling potential of gas–liquid two-phase flow in microchannels for PV cell. ► Introducing the concept of using slug flow in microchannels for cooling of PV cells. ► In single-phase flow, increasing the liquid flow rate enhances the PV power. ► Showing that in two-phase flow the output power related the fluid flow regime. ► By coupling PV and microchannel an increase up to 38% in output power was observed. - Abstract: This paper reports the experimental data from performance of two-phase flows in a small hybrid microchannel solar cell. Using air and water as two-phase fluid, the experiments were conducted at indoor condition in an array of rectangular microchannels with a hydraulic diameter of 0.667 mm. The gas superficial velocity ranges were between 0 and 3.27 m s −1 while liquid flow rate was 0.04 m s −1 . The performance analysis of the PV cell at slug and transitional slug/annular flow regimes are the focus of this study. The influence of two-phase working fluid on PV cell cooling was compared with single-phase. In addition, the great potential of slug flow for heat removal enhancement in PV/T panel was investigated. The obtained data showed the proposed hybrid system could substantially increases the output power of PV solar cells

  11. Simultaneous detection of mRNA and protein stem cell markers in live cells

    Directory of Open Access Journals (Sweden)

    Bao Gang

    2009-04-01

    Full Text Available Abstract Background Biological studies and medical application of stem cells often require the isolation of stem cells from a mixed cell population, including the detection of cancer stem cells in tumor tissue, and isolation of induced pluripotent stem cells after eliciting the expression of specific genes in adult cells. Here we report the detection of Oct-4 mRNA and SSEA-1 protein in live carcinoma stem cells using respectively molecular beacon and dye-labeled antibody, aiming to establish a new method for stem cells detection and isolation. Results Quantification of Oct-4 mRNA and protein in P19 mouse carcinoma stem cells using respectively RT-PCR and immunocytochemistry confirmed that their levels drastically decreased after differentiation. To visualize Oct-4 mRNA in live stem cells, molecular beacons were designed, synthesized and validated, and the detection specificity was confirmed using control studies. We found that the fluorescence signal from Oct-4-targeting molecular beacons provides a clear discrimination between undifferentiated and retinoic acid-induced differentiated cells. Using deconvolution fluorescence microscopy, Oct-4 mRNAs were found to reside on one side of the cytosol. We demonstrated that, using a combination of Oct-4 mRNA-targeting molecular beacon with SSEA-1 antibody in flow cytometric analysis, undifferentiated stem cells can be clearly distinguished from differentiated cells. We revealed that Oct-4 targeting molecular beacons do not seem to affect stem cell biology. Conclusion Molecular beacons have the potential to provide a powerful tool for highly specific detection and isolation of stem cells, including cancer stem cells and induced pluripotent stem (iPS cells without disturbing cell physiology. It is advantageous to perform simultaneous detection of intracellular (mRNA and cell-surface (protein stem cell markers in flow cytometric analysis, which may lead to high detection sensitivity and efficiency.

  12. Downregulation of CXCR4 in Metastasized Breast Cancer Cells and Implication in Their Dormancy

    Science.gov (United States)

    Nobutani, Kentaro; Shimono, Yohei; Mizutani, Kiyohito; Ueda, Yuki; Suzuki, Toshihiro; Kitayama, Midori; Minami, Akihiro; Momose, Kenji; Miyawaki, Kohta; Akashi, Koichi; Azuma, Takeshi; Takai, Yoshimi

    2015-01-01

    Our understanding of the mechanism of cancer dormancy is emerging, but the underlying mechanisms are not fully understood. Here we analyzed mouse xenograft tumors derived from human breast cancer tissue and the human breast cancer cell line MDA-MB-231 to identify the molecules associated with cancer dormancy. In immunohistological examination using the proliferation marker Ki-67, the tumors included both proliferating and dormant cancer cells, but the number of dormant cells was remarkably increased when they metastasized to the lung. In the gene expression analysis of the orthotopic cancer cells by a single-cell multiplex real-time quantitative reverse transcription PCR followed by flow cytometric analysis, restrained cellular proliferation was associated with downregulation of the chemokine receptor CXCR4. In the immunohistological and flow cytometric analyses, the expression level of CXCR4 in the metastasized cancer cells was decreased compared with that in the cancer cells in orthotopic tumors, although the expression level of the CXCR4 ligand CXCL12 was not reduced in the lung. In addition, the proliferation of the metastasized cancer cells was further decreased by the CXCR4 antagonist administration. In the ex vivo culture of the metastasized cancer cells, the expression level of CXCR4 was increased, and in the xenotransplantation of ex vivo cultured cancer cells, the expression level of CXCR4 was again decreased in the metastasized cancer cells in the lung. These findings indicate that CXCR4 is downregulated in metastasized breast cancer cells and implicated in their dormancy. PMID:26083776

  13. Immunocapture of CD133-positive cells from human cancer cell lines by using monodisperse magnetic poly(glycidyl methacrylate) microspheres containing amino groups

    Energy Technology Data Exchange (ETDEWEB)

    Kuan, Wei-Chih [Department of Chemical Engineering, Systems Biology and Tissue Engineering Research Center, National Chung Cheng University, Minhisung 621, Taiwan (China); Horák, Daniel, E-mail: horak@imc.cas.cz [Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic, Heyrovsky Sq. 2, 162 06 Prague 6 (Czech Republic); Plichta, Zdeněk [Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic, Heyrovsky Sq. 2, 162 06 Prague 6 (Czech Republic); Lee, Wen-Chien [Department of Chemical Engineering, Systems Biology and Tissue Engineering Research Center, National Chung Cheng University, Minhisung 621, Taiwan (China)

    2014-01-01

    Magnetic poly(glycidyl methacrylate)-based macroporous microspheres with an average particle size of 4.2 μm were prepared using a modified multi-step swelling polymerization method and by introducing amino functionality on their surfaces. Antibody molecules were oxidized on their carbohydrate moieties and bound to the amino-containing magnetic microspheres via a site-directed procedure. CD133-positive cells could be effectively captured from human cancer cell lines (HepG2, HCT116, MCF7, and IMR-32) by using magnetic microspheres conjugated to an anti-human CD133 antibody. After further culture, the immunocaptured CD133-expressing cells from IMR-32 proliferated and gradually detached from the magnetic microspheres. Flow-cytometric analysis confirmed the enrichment of CD133-expressing cells by using the antibody-bound magnetic microspheres. Such microspheres suitable for immunocapture are very promising for cancer diagnosis because the CD133-expressing cells in cancer cell lines have been suggested to be cancer stem cells. - Highlights: • Multi-step swelling polymerization produced poly(glycidyl methacrylate) microspheres. • Anti-human CD133 antibodies were bound to the amino-containing magnetic microspheres. • CD133-positive cells were effectively captured from human cancer cell lines. • Immunocaptured CD133-expressing cells proliferated and were detached from microspheres. • Enrichment of CD133-expressing cells was confirmed by flow-cytometric analysis.

  14. Laser flow microphotometry for rapid analysis and sorting of mammalian cells. [X and gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Mullaney, P.F.; Steinkamp, J.A.; Crissman, H.A.; Cram, L.S.; Crowell, J.M.; Salzman, G.C.; Martin, J.C.; Price, B.

    1976-01-01

    Quantitative precision measurements can be made of the optical properties of individual mammalian cells using flow microphotometry. Suspended cells pass through a special flow chamber where they are lined up for exposure to blue light from an argon-ion laser. As each cell crosses the laser beam, it produces one or more optical pulses of a duration equal to cell transit time across the beam. These pulses are detected, amplified, and analyzed using the techniques of gamma ray spectroscopy. Quantitative DNA distributions made it possible to distinguish tumor cells from normal cells as well as to assay for radiation effects on tumor cells subjected to x and gamma radiation. (HLW)

  15. Circulating tumor cells: clinically relevant molecular access based on a novel CTC flow cell.

    Directory of Open Access Journals (Sweden)

    Jessamine P Winer-Jones

    Full Text Available BACKGROUND: Contemporary cancer diagnostics are becoming increasing reliant upon sophisticated new molecular methods for analyzing genetic information. Limiting the scope of these new technologies is the lack of adequate solid tumor tissue samples. Patients may present with tumors that are not accessible to biopsy or adequate for longitudinal monitoring. One attractive alternate source is cancer cells in the peripheral blood. These rare circulating tumor cells (CTC require enrichment and isolation before molecular analysis can be performed. Current CTC platforms lack either the throughput or reliability to use in a clinical setting or they provide CTC samples at purities that restrict molecular access by limiting the molecular tools available. METHODOLOGY/PRINCIPAL FINDINGS: Recent advances in magetophoresis and microfluidics have been employed to produce an automated platform called LiquidBiopsy®. This platform uses high throughput sheath flow microfluidics for the positive selection of CTC populations. Furthermore the platform quantitatively isolates cells useful for molecular methods such as detection of mutations. CTC recovery was characterized and validated with an accuracy (<20% error and a precision (CV<25% down to at least 9 CTC/ml. Using anti-EpCAM antibodies as the capture agent, the platform recovers 78% of MCF7 cells within the linear range. Non specific recovery of background cells is independent of target cell density and averages 55 cells/mL. 10% purity can be achieved with as low as 6 CTCs/mL and better than 1% purity can be achieved with 1 CTC/mL. CONCLUSIONS/SIGNIFICANCE: The LiquidBiopsy platform is an automated validated platform that provides high throughput molecular access to the CTC population. It can be validated and integrated into the lab flow enabling CTC enumeration as well as recovery of consistently high purity samples for molecular analysis such as quantitative PCR and Next Generation Sequencing. This tool opens

  16. A flow-through cell with integrated coulometric pH actuator

    NARCIS (Netherlands)

    Bohm, S.; Olthuis, Wouter; Bergveld, Piet

    1998-01-01

    A flow-through cell with integrated coulometric actuator capable of controlling the pH of a flowing liquid is presented. The cell, consisting of a rectangular channel with a noble metal actuator electrode deposited on the bottom, enables the titration of a moving liquid without the need for pumps

  17. Low stoichiometry operation of a proton exchange membrane fuel cell employing the interdigitated flow field

    DEFF Research Database (Denmark)

    Berning, Torsten; Kær, Søren Knudsen

    2012-01-01

    A multiphase fuel cell model based on computational fluid dynamics is used to investigate the possibility of operating a proton exchange membrane fuel cell at low stoichiometric flow ratios (ξ < 1.5) employing the interdigitated flow field design and using completely dry inlet gases. A case study...

  18. An Improved Ghost-cell Immersed Boundary Method for Compressible Inviscid Flow Simulations

    KAUST Repository

    Chi, Cheng

    2015-05-01

    This study presents an improved ghost-cell immersed boundary approach to represent a solid body in compressible flow simulations. In contrast to the commonly used approaches, in the present work ghost cells are mirrored through the boundary described using a level-set method to farther image points, incorporating a higher-order extra/interpolation scheme for the ghost cell values. In addition, a shock sensor is in- troduced to deal with image points near the discontinuities in the flow field. Adaptive mesh refinement (AMR) is used to improve the representation of the geometry efficiently. The improved ghost-cell method is validated against five test cases: (a) double Mach reflections on a ramp, (b) supersonic flows in a wind tunnel with a forward- facing step, (c) supersonic flows over a circular cylinder, (d) smooth Prandtl-Meyer expansion flows, and (e) steady shock-induced combustion over a wedge. It is demonstrated that the improved ghost-cell method can reach the accuracy of second order in L1 norm and higher than first order in L∞ norm. Direct comparisons against the cut-cell method demonstrate that the improved ghost-cell method is almost equally accurate with better efficiency for boundary representation in high-fidelity compressible flow simulations. Implementation of the improved ghost-cell method in reacting Euler flows further validates its general applicability for compressible flow simulations.

  19. Analysis of cell flow and cell loss following X-irradiation using sequential investigation of the total number of cells in the various parts of the cell cycle

    International Nuclear Information System (INIS)

    Skog, S.; Tribukait, B.

    1985-01-01

    The cell flow and cell loss of an in vivo growing Ehrlich ascites tumour were calculated by sequential estimation of changes in total number of cells in the cell cycle compartments. Normal growth was compared with the grossly disturbed cell flow evident after a 5 Gy X-irradiation. The doubling time of normal, exponentially growing cells was 24 hr. The generation time was 21 hr and the potential doubling time was 21 hr. Thus, the growth fraction was 1.0 and the cell loss rate about 0.5%/hr. Following irradiation, a transiently increased relative outflow rate from all cell cycle compartments was found at about 3 and 40 hr, and from S phase at 24 hr after irradiation. Increase in cell loss as well as non-viable cells was observed at 24 hr after irradiation at the time of release of the irradiation-induced G 2 blockage. The experiments show the applicability and limitations of cell flow and cell loss calculations by sequential analysis of the total number of cells in the various parts of the cell cycle. (author)

  20. Prolactin increases CD4/CD8 cell ratio in thymus-grafted congenitally athymic nude mice.

    OpenAIRE

    Gaufo, G O; Diamond, M C

    1996-01-01

    One distinctive effect on T-cell development was analyzed by selectively increasing serum prolactin (PRL) concentration in thymus-grafted congenitally athymic nude mice and by neutralizing PRL in suspension cultures of thymus from 1-day-old neonatal mice. Flow cytometric analysis of single-positive CD4+ and CD8+ cells derived from inguinal lymph nodes revealed a CD4/CD8 cell ratio of 2.2 +/- 0.18 (mean +/- SEM) in thymus-grafted nude mice that is similar to the ratio for immune-competent BALB...

  1. Feasibility study of red blood cell debulking by magnetic field-flow fractionation with step-programmed flow.

    Science.gov (United States)

    Moore, Lee R; Williams, P Stephen; Nehl, Franziska; Abe, Koji; Chalmers, Jeffrey J; Zborowski, Maciej

    2014-02-01

    Emerging applications of rare cell separation and analysis, such as separation of mature red blood cells from hematopoietic cell cultures, require efficient methods of red blood cell (RBC) debulking. We have tested the feasibility of magnetic RBC separation as an alternative to centrifugal separation using an approach based on the mechanism of magnetic field-flow fractionation (MgFFF). A specially designed permanent magnet assembly generated a quadrupole field having a maximum field of 1.68 T at the magnet pole tips, zero field at the aperture axis, and a nearly constant radial field gradient of 1.75 T/mm (with a negligible angular component) inside a cylindrical aperture of 1.9 mm (diameter) and 76 mm (length). The cell samples included high-spin hemoglobin RBCs obtained by chemical conversion of hemoglobin to methemoglobin (met RBC) or by exposure to anoxic conditions (deoxy RBC), low-spin hemoglobin obtained by exposure of RBC suspension to ambient air (oxy RBC), and mixtures of deoxy RBC and cells from a KG-1a white blood cell (WBC) line. The observation that met RBCs did not elute from the channel at the lower flow rate of 0.05 mL/min applied for 15 min but quickly eluted at the subsequent higher flow rate of 2.0 mL/min was in agreement with FFF theory. The well-defined experimental conditions (precise field and flow characteristics) and a well-established FFF theory verified by studies with model cell systems provided us with a strong basis for making predictions about potential practical applications of the magnetic RBC separation.

  2. Computational fluid dynamics simulations of single-phase flow in a filter-press flow reactor having a stack of three cells

    International Nuclear Information System (INIS)

    Sandoval, Miguel A.; Fuentes, Rosalba; Walsh, Frank C.; Nava, José L.; Ponce de León, Carlos

    2016-01-01

    Highlights: • Computational fluid dynamic simulations in a filter-press stack of three cells. • The fluid velocity was different in each cell due to local turbulence. • The upper cell link pipe of the filter press cell acts as a fluid mixer. • The fluid behaviour tends towards a continuous mixing flow pattern. • Close agreement between simulations and experimental data was achieved. - Abstract: Computational fluid dynamics (CFD) simulations were carried out for single-phase flow in a pre-pilot filter press flow reactor with a stack of three cells. Velocity profiles and streamlines were obtained by solving the Reynolds-Averaged Navier-Stokes (RANS) equations with a standard k − ε turbulence model. The flow behaviour shows the appearance of jet flow at the entrance to each cell. At lengths from 12 to 15 cm along the cells channels, a plug flow pattern is developed at all mean linear flow rates studied here, 1.2 ≤ u ≤ 2.1 cm s −1 . The magnitude of the velocity profiles in each cell was different, due to the turbulence generated by the change of flow direction in the last fluid manifold. Residence time distribution (RTD) simulations indicated that the fluid behaviour tends towards a continuous mixing flow pattern, owing to flow at the output of each cell across the upper cell link pipe, which acts as a mixer. Close agreement between simulations and experimental RTD was obtained.

  3. Dynamic Flow Impacts Cell-Particle Interactions: Sedimentation and Particle Shape Effects.

    Science.gov (United States)

    Björnmalm, Mattias; Faria, Matthew; Chen, Xi; Cui, Jiwei; Caruso, Frank

    2016-10-17

    The interaction of engineered particles with biological systems determines their performance in biomedical applications. Although standard static cell cultures remain the norm for in vitro studies, modern models mimicking aspects of the dynamic in vivo environment have been developed. Herein, we investigate fundamental cell-particle interactions under dynamic flow conditions using a simple and self-contained device together with standard multiwell cell culture plates. We engineer two particle systems and evaluate their cell interactions under dynamic flow, and we compare the results to standard static cell cultures. We find substantial differences between static and dynamic flow conditions and attribute these to particle shape and sedimentation effects. These results demonstrate how standard static assays can be complemented by dynamic flow assays for a more comprehensive understanding of fundamental cell-particle interactions.

  4. Single-cell phospho-protein analysis by flow cytometry.

    Science.gov (United States)

    Schulz, Kenneth R; Danna, Erika A; Krutzik, Peter O; Nolan, Garry P

    2012-02-01

    This protocol describes methods for monitoring intracellular phosphorylation-dependent signaling events on a single-cell basis. This approach measures cell signaling by treating cells with exogenous stimuli, fixing cells with formaldehyde, permeabilizing with methanol, and then staining with phospho-specific antibodies. Thus, cell signaling states can be determined as a measure of how cells interact with their environment. This method has applications in clinical research as well as mechanistic studies of basic biology. In clinical research, diagnostic or drug efficacy information can be retrieved by discovering how a disease affects the ability of cells to respond to growth factors. Basic scientists can use this technique to analyze signaling events in cell lines and human or murine primary cells, including rare populations, like B1 cells or stem cells. This technique has broad applications bringing standard biochemical analysis into primary cells in order to garner valuable information about signaling events in physiologic settings. © 2012 by John Wiley & Sons, Inc.

  5. Arctigenin induces apoptosis in colon cancer cells through ROS/p38MAPK pathway.

    Science.gov (United States)

    Li, Qing-chun; Liang, Yun; Tian, Yuan; Hu, Guang-rui

    2016-01-01

    In the current study the antiproliferative effect of arctigenin, plant lignin, was evaluated on human colon cancer cell line HT-29. Furthermore, attempts were made to explore the signaling mechanism which may be responsible for its effect. Cell growth inhibition was assessed by MTT and LDH assays. Flow cytometric analysis was performed to determine cell arrest in the cell cycle phase and apoptosis. Furthermore, to confirm the apoptotic activity of arctigenin, caspase-9 and -3 activities analysis was performed. The levels of reactive oxygen species (ROS) and p38 mitogen activated protein kinase (MAPK) were investigated to determine their role in inducing apoptosis in arctigenin-treated HT-29 colon cancer cell line. MTT and LDH results demonstrated significant cell growth inhibitory effect of arctigenin on HT-29 cells in a dose-dependent manner. Furthermore, increase in cell number arrested at G2/M phase was observed in flow cytometric analysis upon arctigenin treatment. In addition, arctigenin increased the apoptotic ratio in a dose-dependent manner. The involvement of intrinsic apoptotic pathway was indicated by the activation of caspase-9 and -3. Moreover, increased ROS production, activation of p38 MAPK and changes in mitochondrial membrane potential (ΔΨm) also revealed the role of intrinsic apoptotic signaling pathway in cell growth inhibition after arctigenin exposure. Arctigenin induces apoptosis in HT-29 colon cancer cells by regulating ROS and p38 MAPK pathways.

  6. An experimental investigation of pressurized planar solid oxide fuel cells using two different flow distributors

    Science.gov (United States)

    Chang, H. W.; Huang, C. M.; Shy, S. S.

    2014-03-01

    A high-pressure high-temperature dual-chamber facility is established for electrochemical impedance measurements of pressurized solid oxide fuel cells (PSOFC) to explain why and how the cell performance is increased with increasing pressure (p). By comparing two sets of nearly identical single-cell stacks except using different flow distributors with different degrees of flow uniformity at 850 °C over a range of p varying from 0.1 MPa to 0.5 MPa, we found that the better flow uniformity in flow distributors is, the better the cell performance is, and such performance enhancement is increased with increasing p. This finding is explained by impedance spectra and their associated equivalent circuit models, showing the coupling impact of flow uniformity and pressure elevation to the decrease of ohmic and polarization resistances. These results should be useful to the development of PSOFC integrating with micro gas turbines for future stationary power generation.

  7. Orientation of Cells Cultured in Vortex Flow with Swinging Plate in Vitro

    Directory of Open Access Journals (Sweden)

    Shigehiro Hashimoto

    2011-06-01

    Full Text Available An effect of flow on cell culture has been studied in vitro. A silicone disk was placed in the center of culture dish of 52 mm internal diameter to make a doughnut-shaped canal. The dish was placed on a tilted plate, which rotates to make a vortex flow around the silicone disk with a swing motion. Variations were made on the diameter (20 mm, 30 mm, and 40 mm of the silicone disk and the rotational speed (2.1 rad/sec, 5.2 rad/sec of the swinging plate, which tilts with 0.1 rad from the horizontal plane. Five kinds of cells were cultured in the vortex flow of Dulbecco’s Modified Eagle’s Medium for seven days: C2C12 (mouse myoblast, L6 (rat skeletal muscle cell, A7r5 (rat aortic smooth muscle cell, CS-2P2-C75 (primary normal porcine aortic endothelial cell, and L929 (mouse fibroblast. The experiments show the following results. The orientation of cells depends on flow and on kinds of cells. A7r5 and CS-2P2-C75 line along the streamline of the flow. C2C12 and L6 adhere along the direction of the flow in the first stage, and tilt to the perpendicular direction to the flow differentiating to myotubes with fusion in the second stage.

  8. Flow and Pressure Distribution in Fuel Cell Manifolds

    DEFF Research Database (Denmark)

    Lebæk, Jesper; Bang, Mads; Kær, Søren Knudsen

    2010-01-01

    The manifold is an essential part of the fuel cell stack. Evidently, evenly distributed reactants are a prerequisite for an efficient fuel cell stack. In this study, the cathode manifold ability to distribute air to the cells of a 70 cell stack is investigated experimentally. By means of 20...

  9. Laminar flow in radial flow cell with small aspect ratios: Numerical and experimental study

    DEFF Research Database (Denmark)

    Detry, J. G.; Deroanne, C.; Sindic, M.

    2009-01-01

    Studies on the effect of wall shear stress on soil and biofilm attachment and removal from a surface are one of the many applications of radial axisymmetrical flow. The particular nature of this flow allows taking advantage of a wide range of wall shear Stress applied at the analyzed surface...... in a single experiment. This type of experiments provides a critical radius up to which soil removal occurs. Good models are, however, still needed to convert the experimental data into critical wall shear stress. Analytical models are already available for creeping flow but Computational Fluid Dynamics must...... be applied for experiments performed at higher Reynolds numbers. The present study is a numerical analysis of the radial axisymmetrical flow for aspect ratios of 0.125, 0.25, 0.5 and 1 with inlet pipe Reynolds numbers varying from 0 to 2000, aiming at computing the wall shear stress distribution at any...

  10. DNA polymeric films as a support for cell growth as a new material for regenerative medicine: Compatibility and applicability.

    Science.gov (United States)

    Jayme, Cristiano Ceron; de Paula, Leonardo Barcelos; Rezende, Nayara; Calori, Italo Rodrigo; Franchi, Leonardo Pereira; Tedesco, Antonio Claudio

    2017-11-15

    DNA polymeric films (DNA-PFs) are a promising drug delivery system (DDS) in modern medicine. In this study, we evaluated the growth behavior of oral squamous cell carcinoma (OSCC) cells on DNA-PFs. The morphological, biochemical, and cytometric features of OSCC cell adhesion on DNA-PFs were also assessed. An initial, temporary alteration in cell morphology was observed at early time points owing to the inhibition of cell attachment to the film, which then returned to a normal morphological state at later time points. MTT and resazurin assays showed a moderate reduction in cell viability related to increased DNA concentration in the DNA-PFs. Flow cytometry studies showed low cytotoxicity of DNA-PFs, with cell viabilities higher than 90% in all the DNA-PFs tested. Flow cytometric cell cycle analysis also showed average cell cycle phase distributions at later time points, indicating that OSCC cell growth is maintained in the presence of DNA-PFs. These results show high biocompatibility of DNA-PFs and suggest their use in designing "dressing material," where the DNA film acts as a support for cell growth, or with incorporation of active or photoactive compounds, which can induce tissue regeneration and are useful to treat many diseases, especially oral cancer. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Interferon-¿ production by human T cells and natural killer cells in vitro in response to antigens from the two intracellular pathogens Mycobacterium tuberculosis and Leishmania major

    DEFF Research Database (Denmark)

    Kemp, K; Hviid, L; Kharazmi, A

    1997-01-01

    Acquired resistance to both mycobacteria and Leishmania is primarily mediated by interferon-gamma (IFN-gamma), which triggers mechanisms leading to the death of the microorganism in macrophages. In this study, cell activation and IFN-gamma production was investigated in human peripheral blood...... mononuclear cells (PBMC) from individuals previously sensitized to tuberculin and without known exposure to Leishmania parasites. Immune staining for intracellular IFN-gamma and surface markers allowed flow cytometric identification of the cellular sources of IFN-gamma in cell cultures incubated with purified...

  12. Flow field design for high-pressure PEM electrolysis cells

    DEFF Research Database (Denmark)

    Olesen, Anders Christian; Kær, Søren Knudsen

    -water distributes. Water not only serves a reactant, it also aids in cooling due to its high specific heat capacity. The movement of liquid water at the anode is difficult to model, since it is highly coupled to the formation of gas bubbles. To capture the complex two-phase flow behaviour that takes place within...... micro-channels and porous media, our research group has developed an Euler-Euler model in the computational fluid dynamics modelling framework of ANSYS CFX. In addition to two-phase flow, the model accounts for turbulence, species transport in the gas phase, heat transport in all three phases (i.......e. solid, gas and liquid), as well as charge transport of electrons and ions. Our recent improvements have focused on the models ability to account for phase change and electrochemistry as well as the modelling of two-phase flow regimes. For comparison, an interdigitated and parallel channel flow field...

  13. A novel GuttaFlow sealer supports cell survival and attachment.

    Science.gov (United States)

    Accardo, Chelsea; Himel, Van T; Lallier, Thomas E

    2014-02-01

    The purpose of this in vitro study was to compare the biocompatibility of a novel formulation of a silicone-based endodontic sealer GuttaFlow 2 (GF2; Coltène/Whaledent, Langenau, Germany) with the original (GFO) and fast-set (GFF) formulations of GuttaFlow and with an epoxy resin sealer, AHPlus Jet (AH+J; Dentsply, York, PA). Sealers were set into 3 × 5.5 mm discs. Cell culture media was used to extract leachable products at 24 hours and 1, 2, and 4 weeks. Primary human periodontal ligament fibroblasts were incubated with sealer elutes for 24 hours and evaluated using the 3-(4, 5-dimethylthiazol-2-yl)-2, 5-diphenyltetrazolium bromide assay and the calcein AM assay. Cell attachment was evaluated on set sealer that was either rinsed or unrinsed with cell media for 1 week. Statistical analysis was performed using the Student t test. Both calcein and 3-(4, 5-dimethylthiazol-2-yl)-2, 5-diphenyltetrazolium bromide assays revealed that periodontal ligament cell viability was reduced on AH+J at 1, 2, and 4 weeks compared with all GuttaFlow sealers. There were no differences in cell viability between the GuttaFlow samples, and all displayed high rates of cell survival at all time periods. After 2 hours, cell attachment to the rinsed GFO and GFF samples exceeded the control, and at 24 hours cell attachment on all GuttaFlow samples exceeded the control. AH+J sealers supported significantly less cell attachment when compared with all GuttaFlow sealers. Cell attachment to set sealers showed better cell attachment when rinsed compared with unrinsed. GuttaFlow sealers were more biocompatible than AHJ in vitro. The novel GF2 displayed comparable biocompatibility with GFF and GFO. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  14. A tapered serpentine flow field for the anode of micro direct methanol fuel cells

    Science.gov (United States)

    Zhang, Yufeng; Zhang, Peng; Yuan, Zhenyu; He, Hong; Zhao, Youran; Liu, Xiaowei

    2011-03-01

    We develop a self-breathing micro direct methanol fuel cell (μDMFC) characterized by a new anode structure with tapered single serpentine flow fields to improve cell performance. Compared with the conventional single serpentine flow field, this new design enhances the methanol mass transport efficiency and the exhaust resultant (CO2) rate due to the increasing pressure difference between adjacent flow channels. The μDMFCs with two single serpentine flow fields are fabricated using silicon-based micro-electro-mechanical systems (MEMS) technologies and are tested at room temperature. The experimental results reveal that the new tapered single serpentine flow field exhibits a significantly higher peak power density than that of the conventional flow field, demonstrating a substantial increase of 17.9% in mass transport coefficients.

  15. The effect of blood cell count on coronary flow in patients with coronary slow flow phenomenon.

    Science.gov (United States)

    Soylu, Korhan; Gulel, Okan; Yucel, Huriye; Yuksel, Serkan; Aksan, Gokhan; Soylu, Ayşegül İdil; Demircan, Sabri; Yılmaz, Ozcan; Sahin, Mahmut

    2014-09-01

    The coronary slow flow phenomenon (CSFP) is a coronary artery disease with a benign course, but its pathological mechanisms are not yet fully understood.The purpose of this controlled study was to investigate the cellular content of blood in patients diagnosed with CSFP and the relationship of this with coronary flow rates. Selective coronary angiographies of 3368 patients were analyzed to assess Thrombolysis in Myocardial Infarction (TIMI) frame count (TFC) values. Seventy eight of them had CSFP, and their demographic and laboratory findings were compared with 61 patients with normal coronary flow. Patients' demographic characteristics were similar in both groups. Mean corrected TFC (cTFC) values were significantly elevated in CSFP patients (p<0.001). Furthermore, hematocrit and hemoglobin values, and eosinophil and basophil counts of the CSFP patients were significantly elevated compared to the values obtained in the control group (p=0.005, p=0.047, p=0.001 and p=0.002, respectively). The increase observed in hematocrit and eosinophil levels showed significant correlations with increased TFC values (r=0.288 and r=0.217, respectively). Significant changes have been observed in the cellular composition of blood in patients diagnosed with CSFP as compared to the patients with normal coronary blood flow. The increases in hematocrit levels and in the eosinophil and basophil counts may have direct or indirect effects on the rate of coronary blood flow.

  16. An improved ghost-cell immersed boundary method for compressible flow simulations

    KAUST Repository

    Chi, Cheng

    2016-05-20

    This study presents an improved ghost-cell immersed boundary approach to represent a solid body in compressible flow simulations. In contrast to the commonly used approaches, in the present work ghost cells are mirrored through the boundary described using a level-set method to farther image points, incorporating a higher-order extra/interpolation scheme for the ghost cell values. A sensor is introduced to deal with image points near the discontinuities in the flow field. Adaptive mesh refinement (AMR) is used to improve the representation of the geometry efficiently in the Cartesian grid system. The improved ghost-cell method is validated against four test cases: (a) double Mach reflections on a ramp, (b) smooth Prandtl-Meyer expansion flows, (c) supersonic flows in a wind tunnel with a forward-facing step, and (d) supersonic flows over a circular cylinder. It is demonstrated that the improved ghost-cell method can reach the accuracy of second order in L1 norm and higher than first order in L∞ norm. Direct comparisons against the cut-cell method demonstrate that the improved ghost-cell method is almost equally accurate with better efficiency for boundary representation in high-fidelity compressible flow simulations. Copyright © 2016 John Wiley & Sons, Ltd.

  17. Deterministic Capture of Individual Circulating Tumor Cells Using a Flow-Restricted Microfluidic Trap Array

    Directory of Open Access Journals (Sweden)

    Yousang Yoon

    2018-03-01

    Full Text Available Circulating tumor cells (CTCs are regarded as a strong biomarker which includes clinically valuable information. However, CTCs are very rare and require precise separation and detection for effective clinical applications. Furthermore, downstream analysis has become necessary to identify the distinct sub-population of CTCs that causes metastasis. Here, we report a flow-restricted microfluidic trap array capable of deterministic single-cell capture of CTCs. The extent of flow restriction, correlating with the device geometry, was then optimized using a highly invasive breast cancer cell line (LM2 MDA-MB-231 to achieve 97% capture efficiency with a single-cell capture rate of 99%. Single-cell capture of CTCs from mice with full-blown metastasis was also demonstrated. The single-CTC capturing ability of the flow-restricted trap array not only showed cell enumerating ability but also high prospects for application in future automated downstream analysis.

  18. Optimization of a new flow design for solid oxide cells using computational fluid dynamics modelling

    DEFF Research Database (Denmark)

    Duhn, Jakob Dragsbæk; Jensen, Anker Degn; Wedel, Stig

    2016-01-01

    Design of a gas distributor to distribute gas flow into parallel channels for Solid Oxide Cells (SOC) is optimized, with respect to flow distribution, using Computational Fluid Dynamics (CFD) modelling. The CFD model is based on a 3d geometric model and the optimized structural parameters include...

  19. Comparison of Flow-Through Cell and Paddle Methods for Testing ...

    African Journals Online (AJOL)

    HP

    Purpose: To evaluate the usefulness of the flow-through cell apparatus for testing commercial vaginal tablets containing poorly water-soluble clotrimazole. Methods: The effect of experimental conditions (type of dissolution medium, flow rate and positioning of the tablet) on the dissolution profile of clotrimazole were ...

  20. Non-Flow-Through Fuel Cell System Test Results and Demonstration on the SCARAB Rover

    Science.gov (United States)

    Scheidegger, Brianne, T.; Burke, Kenneth A.; Jakupca, Ian J.

    2012-01-01

    This paper describes the results of the demonstration of a non-flow-through PEM fuel cell as part of a power system on the SCARAB rover. A 16-cell non-flow-through fuel cell stack from Infinity Fuel Cell and Hydrogen, Inc. was incorporated into a power system designed to act as a range extender by providing power to the rover s hotel loads. This work represents the first attempt at a ground demonstration of this new technology aboard a mobile test platform. Development and demonstration were supported by the Office of the Chief Technologist s Space Power Systems Project and the Advanced Exploration System Modular Power Systems Project.

  1. Finite element analysis of turbulent flow in fast reactor fuel subassembly elementary flow cell

    International Nuclear Information System (INIS)

    Muehlbauer, P.

    1987-03-01

    The method is described of calculating fully developed longitudinal steady-state turbulent flow of an incompressible fluid through an infinite bundle of parallel smooth rods, based on the finite element method and one-equation turbulence model. Theoretical calculation results are compared with experimental results. (author). 5 figs., 3 refs

  2. Flow

    DEFF Research Database (Denmark)

    Knoop, Hans Henrik

    2006-01-01

    FLOW. Orden i hovedet på den fede måde Oplevelsesmæssigt er flow-tilstanden kendetegnet ved at man er fuldstændig involveret, fokuseret og koncentreret; at man oplever stor indre klarhed ved at vide hvad der skal gøres, og i hvilket omfang det lykkes; at man ved at det er muligt at løse opgaven...

  3. Affinity flow fractionation of cells via transient interactions with asymmetric molecular patterns

    Science.gov (United States)

    Bose, Suman; Singh, Rishi; Hanewich-Hollatz, Mikhail; Shen, Chong; Lee, Chia-Hua; Dorfman, David M.; Karp, Jeffrey M.; Karnik, Rohit

    2013-07-01

    Flow fractionation of cells using physical fields to achieve lateral displacement finds wide applications, but its extension to surface molecule-specific separation requires labeling. Here we demonstrate affinity flow fractionation (AFF) where weak, short-range interactions with asymmetric molecular patterns laterally displace cells in a continuous, label-free process. We show that AFF can directly draw neutrophils out of a continuously flowing stream of blood with an unprecedented 400,000-fold depletion of red blood cells, with the sorted cells being highly viable, unactivated, and functionally intact. The lack of background erythrocytes enabled the use of AFF for direct enumeration of neutrophils by a downstream detector, which could distinguish the activation state of neutrophils in blood. The compatibility of AFF with capillary microfluidics and its ability to directly separate cells with high purity and minimal sample preparation will facilitate the design of simple and portable devices for point-of-care diagnostics and quick, cost-effective laboratory analysis.

  4. Affinity flow fractionation of cells via transient interactions with asymmetric molecular patterns.

    Science.gov (United States)

    Bose, Suman; Singh, Rishi; Hanewich-Hollatz, Mikhail; Shen, Chong; Lee, Chia-Hua; Dorfman, David M; Karp, Jeffrey M; Karnik, Rohit

    2013-01-01

    Flow fractionation of cells using physical fields to achieve lateral displacement finds wide applications, but its extension to surface molecule-specific separation requires labeling. Here we demonstrate affinity flow fractionation (AFF) where weak, short-range interactions with asymmetric molecular patterns laterally displace cells in a continuous, label-free process. We show that AFF can directly draw neutrophils out of a continuously flowing stream of blood with an unprecedented 400,000-fold depletion of red blood cells, with the sorted cells being highly viable, unactivated, and functionally intact. The lack of background erythrocytes enabled the use of AFF for direct enumeration of neutrophils by a downstream detector, which could distinguish the activation state of neutrophils in blood. The compatibility of AFF with capillary microfluidics and its ability to directly separate cells with high purity and minimal sample preparation will facilitate the design of simple and portable devices for point-of-care diagnostics and quick, cost-effective laboratory analysis.

  5. Rapid Detection of γ-H2AX by Flow Cytometry in Cultured Mammalian Cells.

    Science.gov (United States)

    Firsanov, Denis; Solovjeva, Liudmila; Lublinskaya, Olga; Zenin, Valeriy; Kudryavtsev, Igor; Serebryakova, Maria; Svetlova, Maria

    2017-01-01

    Methods commonly used for detection of DNA double-strand breaks (DSBs) and analysis of cell death are generally time-consuming, and, therefore, any improvements in these techniques are important for researchers and clinicians. At present, flow cytometry is the most rapid method for detection of DSBs and cell viability. In this chapter, we provide our experience and methodological modification of flow cytometry protocol for the detection of γ-H2AX, a well-known marker of DSBs, in fixed mammalian fibroblasts. The modifications permit a reduction in the time required for DSB detection by flow cytometry.

  6. Interstitial Fluid Flow: The Mechanical Environment of Cells and Foundation of Meridians

    Directory of Open Access Journals (Sweden)

    Wei Yao

    2012-01-01

    Full Text Available Using information from the deep dissection, microobservation, and measurement of acupoints in the upper and lower limbs of the human body, we developed a three-dimensional porous medium model to simulate the flow field using FLUENT software and to study the shear stress on the surface of interstitial cells (mast cells caused by interstitial fluid flow. The numerical simulation results show the following: (i the parallel nature of capillaries will lead to directional interstitial fluid flow, which may explain the long interstitial tissue channels or meridians observed in some experiments; (ii when the distribution of capillaries is staggered, increases in the velocity alternate, and the velocity tends to be uniform, which is beneficial for substance exchange; (iii interstitial fluid flow induces a shear stress, with magnitude of several Pa, on interstitial cell membranes, which will activate cells and lead to a biological response; (iv capillary and interstitial parameters, such as capillary density, blood pressure, capillary permeability, interstitial pressure, and interstitial porosity, affect the shear stress on cell surfaces. The numerical simulation results suggest that in vivo interstitial fluid flow constitutes the mechanical environment of cells and plays a key role in guiding cell activities, which may explain the meridian phenomena and the acupuncture effects observed in experiments.

  7. A Noninvasive Approach to Determine Viscoelastic Properties of an Individual Adherent Cell under Fluid Flow

    Science.gov (United States)

    Qiu, Jun; Baik, Andrew D.; Lu, X. Lucas; Hillman, Elizabeth M. C.; Zhuang, Zhuo; Dong, Cheng; Guo, X. Edward

    2014-01-01

    Mechanical properties of cells play an important role in their interaction with the extracellular matrix as well as the mechanotransduction process. Several in vitro techniques have been developed to determine the mechanical properties of cells, but none of them can measure the viscoelastic properties of an individual adherent cell in fluid flow non-invasively. In this study, techniques of fluid-structure interaction (FSI) finite element method and quasi-3-dimensional (quasi-3D) cell microscopy were innovatively applied to the frequently used flow chamber experiment, where an adherent cell was subjected to fluid flow. A new non-invasive approach, with cells at close to physiological conditions, was established to determine the viscoelastic properties of individual cells. The results showed an instantaneous modulus of osteocytes of 0.49±0.11 kPa, an equilibrium modulus of 0.31±0.044 kPa, and an apparent viscosity coefficient of 4.07±1.23 kPa·s. This new quantitative approach not only provides an excellent means to measure cell mechanical properties, but also may help to elucidate the mechanotransduction mechanisms for a variety of cells under fluid flow stimulation. PMID:24581798

  8. Capture of circulating tumor cells using photoacoustic flowmetry and two phase flow.

    Science.gov (United States)

    O'Brien, Christine M; Rood, Kyle D; Bhattacharyya, Kiran; DeSouza, Thiago; Sengupta, Shramik; Gupta, Sagar K; Mosley, Jeffrey D; Goldschmidt, Benjamin S; Sharma, Nikhilesh; Viator, John A

    2012-06-01

    Melanoma is the deadliest form of skin cancer, yet current diagnostic methods are unable to detect early onset of metastatic disease. Patients must wait until macroscopic secondary tumors form before malignancy can be diagnosed and treatment prescribed. Detection of cells that have broken off the original tumor and travel through the blood or lymph system can provide data for diagnosing and monitoring metastatic disease. By irradiating enriched blood samples spiked with cultured melanoma cells with nanosecond duration laser light, we induced photoacoustic responses in the pigmented cells. Thus, we can detect and enumerate melanoma cells in blood samples to demonstrate a paradigm for a photoacoustic flow cytometer. Furthermore, we capture the melanoma cells using microfluidic two phase flow, a technique that separates a continuous flow into alternating microslugs of air and blood cell suspension. Each slug of blood cells is tested for the presence of melanoma. Slugs that are positive for melanoma, indicated by photoacoustic waves, are separated from the cytometer for further purification and isolation of the melanoma cell. In this paper, we evaluate the two phase photoacoustic flow cytometer for its ability to detect and capture metastatic melanoma cells in blood.

  9. Effects of Red Blood Cell Aggregation on the Apparent Viscosity of Blood Flow in Tubes.

    Science.gov (United States)

    Hitt, Darren L.; Lowe, Mary L.

    1996-11-01

    In arterioles and venules (20-200μ diameter), the low shear rates enable red blood cells to form aggregate structures of varying sizes and morphology. The size and distribution of the aggregates affect the flow impedance within a microvascular network; this effect may be characterized by an "apparent viscosity". In this study, we measure the apparent viscosity of blood flow in 50μ glass tubes as a function of shear rate and red blood cell volume fraction (hematocrit); for a fixed tube geometry and an imposed flow rate, the viscosity is determined by measuring the pressure drop across the tube. To correlate the apparent viscosity with the size and spatial distribution of the aggregates in the flow, video images of the flow are recorded and analyzed using power spectral techniques. Pig blood and sheep blood are used as the models for aggregating and non-aggregating blood, respectively. Supported by NSF PFF Award CTS-9253633

  10. Lattice Boltzmann modeling of transport phenomena in fuel cells and flow batteries

    Science.gov (United States)

    Xu, Ao; Shyy, Wei; Zhao, Tianshou

    2017-06-01

    Fuel cells and flow batteries are promising technologies to address climate change and air pollution problems. An understanding of the complex multiscale and multiphysics transport phenomena occurring in these electrochemical systems requires powerful numerical tools. Over the past decades, the lattice Boltzmann (LB) method has attracted broad interest in the computational fluid dynamics and the numerical heat transfer communities, primarily due to its kinetic nature making it appropriate for modeling complex multiphase transport phenomena. More importantly, the LB method fits well with parallel computing due to its locality feature, which is required for large-scale engineering applications. In this article, we review the LB method for gas-liquid two-phase flows, coupled fluid flow and mass transport in porous media, and particulate flows. Examples of applications are provided in fuel cells and flow batteries. Further developments of the LB method are also outlined.

  11. Cinnamic Acid (CINN Induces Apoptosis and Proliferation in Human Nasopharyngeal Carcinoma Cells

    Directory of Open Access Journals (Sweden)

    Guangying Qi

    2016-11-01

    Full Text Available Background/Aims: CINN is the main ingredient of the traditional Chinese medicine cinnamon. The purpose of the present study was to investigate the effects of CINN on the proliferation and apoptosis of NPC cells and to elucidate the underlying molecular mechanisms. Materials and Methods: CNE2 human NPC cells were treated with various CINN concentrations. The effects of CINN on the proliferation and apoptosis of CNE2 NPC cells were examined using the MTT assay and flow cytometric analysis. Additionally, western blotting was performed to analyze the expression of a number of cell cycle- and apoptosis-related proteins. Results: The proliferation of CNE2 cells was significantly inhibited after treatment with different CINN concentrations for various lengths of time. The inhibitory effect of CINN was concentration-and time-dependent. Flow cytometric analysis showed that 2 mmol/L CINN displayed a significant apoptosis-inducing effect. The western blot analysis results showed that KLF6, Fas-L, Bax, P53 and caspase-3 protein expression was drastically increased in the CNE2 cells after treatment with 2 mmol/L CINN, whereas Bcl-2 and cyclin D1 protein expression was markedly reduced. Conclusion: CINN inhibits the proliferation and induces the apoptosis of CNE2 cells. Therefore, CINN possesses a potential anti-tumor effect.

  12. Continuous enrichment of circulating tumor cells using a microfluidic lateral flow filtration chip.

    Science.gov (United States)

    Lee, Sung-Woo; Hyun, Kyung-A; Kim, Seung-Il; Kang, Ji-Yoon; Jung, Hyo-Il

    2015-01-16

    The isolation and characterization of circulating tumor cells (CTC) is of great importance in cancer diagnosis and prognosis. Highly sensitive detection of CTCs can be very difficult because they are extremely rare (i.e., 1-5 CTCs per 10(9) erythrocytes) in blood. Recently, various devices have been developed that exploit biochemical (affinity-based) and physical (size or density) methods. Antibody-based isolation has its own limitations, as the expression level of the epitopes for an antibody varies due to the heterogeneity of cancer cells. Harsh conditions associated with physical methods can cause the deformation and damage of CTCs during the isolation process. Here, we propose a microfluidic lateral flow filtration (μ-LaFF) chip in which lateral flow was combined with vertical flow into the filter to capture the CTCs gently. The CTCs experienced weak shear flow owing to the lateral flow and traveled alongside the filter channel until finally being captured. The vertical flow in the filter held the captured cells tightly and served as an exit for uncaptured hematological cells (white and red blood cells). From our μ-LaFF chip we obtained a high capture efficiency (95%) and purity (99%), minimizing any damage to the CTCs. Our μ-LaFF technology is expected to be useful in the diagnosis and prognosis of various cancers. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Supercontinuum white light lasers for flow cytometry

    OpenAIRE

    Telford, William G.; Subach, Fedor V.; Verkhusha, Vladislav V.

    2009-01-01

    Excitation of fluorescent probes for flow cytometry has traditionally been limited to a few discrete laser lines, an inherent limitation in our ability to excite the vast array of fluorescent probes available for cellular analysis. In this report, we have used a supercontinuum (SC) white light laser as an excitation source for flow cytometry. By selectively filtering the wavelength of interest, almost any laser wavelength in the visible spectrum can be separated and used for flow cytometric a...

  14. Glycerol-treated nuclear suspensions - an efficient preservation method for flow cytometric analysis of plant samples

    Czech Academy of Sciences Publication Activity Database

    Kolář, Filip; Lučanová, Magdalena; Těšitel, J.; Loureiro, J.; Suda, Jan

    2012-01-01

    Roč. 20, č. 2 (2012), s. 303-315 ISSN 0967-3849 R&D Projects: GA ČR GD206/08/H049 Institutional research plan: CEZ:AV0Z60050516 Institutional support: RVO:67985939 Keywords : cytometry * ploidy * genome size Subject RIV: EF - Botanics Impact factor: 2.847, year: 2012

  15. Long-term storage of samples for flow cytometric DNA analysis

    DEFF Research Database (Denmark)

    Vindeløv, L L; Christensen, I J; Keiding, N

    1983-01-01

    estimation by deconvolution, there was significant intraday and interday variation. Hence the most accurate results are obtained if different aliquots of a sample are measured on different days rather than on the same day. Use of the storage method thus has the potential of increasing the accuracy...

  16. DEA 1 Expression on Dog Erythrocytes Analyzed by Immunochromatographic and Flow Cytometric Techniques

    OpenAIRE

    Acierno, M.M.; Raj, K.; Giger, U.

    2014-01-01

    Background The Dog erythrocyte antigen (DEA) 1 blood group system was thought to contain types DEA 1.1 and 1.2 (and possibly 1.3 [A3]). However, DEA 1.2+ dogs are very rare and newer typing methods reveal varying degrees of DEA 1 positivity. Objectives To assess if variation in DEA 1 positivity is because of quantitative differences in surface antigen expression. To determine expression patterns in dogs over time and effects of blood storage (4?C). To evaluate DEA 1.2+ samples by DEA 1 typing...

  17. Monitoring of Legionella pneumophila viability after chlorine dioxide treatment using flow cytometry.

    Science.gov (United States)

    Mustapha, Pascale; Epalle, Thibaut; Allegra, Séverine; Girardot, Françoise; Garraud, Olivier; Riffard, Serge

    2015-04-01

    The viability of three Legionella pneumophila strains was monitored after chlorine dioxide (ClO2) treatment using a flow cytometric assay. Suspensions of L. pneumophila cells were submitted to increasing concentrations of ClO2. Culturable cells were still detected when using 4 mg/L, but could no longer be detected after exposure to 6 mg/L of ClO2, although viable but not culturable (VBNC) cells were found after exposure to 4-5 mg/L of ClO2. When testing whether these VBNC were infective, two of the strains were resuscitated after co-culture with Acanthamoeba polyphaga, but neither of them could infect macrophage-like cells. Copyright © 2015 Institut Pasteur. Published by Elsevier Masson SAS. All rights reserved.

  18. VOF modelling of gas–liquid flow in PEM water electrolysis cell micro-channels

    DEFF Research Database (Denmark)

    Lafmejani, Saeed Sadeghi; Olesen, Anders Christian; Kær, Søren Knudsen

    2017-01-01

    In this study, the gaseliquid flow through an interdigitated anode flow field of a PEM water electrolysis cell (PEMEC) is analysed using a three-dimensional, transient, computational fluid dynamics (CFD) model. To account for two-phase flow, the volume of fluid (VOF) method in ANSYS Fluent 17...... of the gaseliquid flow in a transparent micro-channel, are qualitative compared against the simulation results. The experimental observations confirm the models prediction of long Taylor bubbles with small bubbles in between. From the simulation results, further intriguing details of the flow are revealed. From...... the bottom to the top of the outgoing channel, the film thickness gradually increases from zero to 200 mm. This increase in the film thickness is due to the particular superficial velocity field that develops in an interdigitated flow. Here both the superficial velocities change along the length...

  19. A new modified-serpentine flow field for application in high temperature polymer electrolyte fuel cell

    DEFF Research Database (Denmark)

    Singdeo, Debanand; Dey, Tapobrata; Gaikwad, Shrihari

    2017-01-01

    Flow field design for the distribution of reactants and products on the electrode surface plays an important role in the overall performance of the fuel cell. It acts as a crucial factor when the laboratory scale fuel cell is scaled up for commercial applications. In the present work, a novel flo...

  20. Miniaturized cavity ring-down detection in a liquid flow cell

    NARCIS (Netherlands)

    Bahnev, B.; van der Sneppen, L.; Wiskerke, A.E.; Ariese, F.; Gooijer, C.; Ubachs, W.M.G.

    2005-01-01

    A novel method for applying cavity ring-down spectroscopy in the liquid phase, compatible with LC analyses, is presented. The core of the setup is a home-built cavity ring-down flow cell (cell volume 12 μL) that is constructed using a silicon rubber spacer, which is clamped leak-tight between two

  1. Water flow induced transport of Pseudomonas fluorescens cells through soil columns as affected by inoculant treatment

    NARCIS (Netherlands)

    Hekman, W.E.; Heijnen, C.E.; Trevors, J.T.; Elsas, van J.D.

    1994-01-01

    Water flow induced transport of Pseudomonas fluorescens cells through soil columns was measured as affected by the inoculant treatment. Bacterial cells were introduced into the topsoil of columns, either encapsulated in alginate beads of different types or mixed with bentonite clay in concentrations

  2. Detection of alloreactive T cells by flow cytometry : A new test compared with limiting dilution assay

    NARCIS (Netherlands)

    de Haan, A; van der Gun, [No Value; van der Bij, W; de Leij, LFMH; Prop, J

    2002-01-01

    Background. Frequencies of alloreactive T cells determined by limiting dilution assays (LDA) may not adequately reflect the donor-reactive immune status in transplant recipients. To reevaluate LDA frequencies, we developed a flow cytometry test for direct determination of alloreactive T-cell

  3. Analysis on the design and property of flow field plates of innovative direct methanol fuel cell.

    Science.gov (United States)

    Chang, Ho; Kao, Mu-Jung; Chen, Chih-Hao; Kuo, Chin-Guo; Lee, Kuang-Ying

    2014-10-01

    The paper uses technology of lithography process to etch flow fields on single side of a printed circuit board (PCB), and combines flow field plate with collector plate to make innovative anode flow field plates and cathode flow field plates required in direct methanol fuel cell (DMFC), and meanwhile makes membrane electrode assembly (MEA) and methanol fuel plate. The flow field plates are designed to be in the form of serpentine flow field. The paper measured the assembled DMFC to achieve the overall efficiency of DMFC under the conditions of different screw torques and different concentration, flow rate and temperature of methanol. Experimental results show that when the flow field width of flow field plate is 1 mm, the screw torque is 16 kgf/cm, and the concentration, flow rate and temperature of methanol-water are 1 M, 180 ml/h and 50 degrees C respectively, the prepared DMFC can have better power density of 5.5 mW/cm2, 5.4 mW/cm2, 11.2 mW/cm2 and 11.8 mW/cm2. Besides, the volume of the DMFC designed and assembled by the study is smaller than the generally existing DMFC by 40%.

  4. Fluid flow releases fibroblast growth factor-2 from human aortic smooth muscle cells

    Science.gov (United States)

    Rhoads, D. N.; Eskin, S. G.; McIntire, L. V.

    2000-01-01

    This study tested the hypothesis that fluid shear stress regulates the release of fibroblast growth factor (FGF)-2 from human aortic smooth muscle cells. FGF-2 is a potent mitogen that is involved in the response to vascular injury and is expressed in a wide variety of cell types. FGF-2 is found in the cytoplasm of cells and outside cells, where it associates with extracellular proteoglycans. To test the hypothesis that shear stress regulates FGF-2 release, cells were exposed to flow, and FGF-2 amounts were measured from the conditioned medium, pericellular fraction (extracted by heparin treatment), and cell lysate. Results from the present study show that after 15 minutes of shear stress at 25 dyne/cm(2) in a parallel-plate flow system, a small but significant fraction (17%) of the total FGF-2 was released from human aortic smooth muscle cells. FGF-2 levels in the circulating medium increased 10-fold over medium from static controls (PFlow cytometry detected a 50% increase in mean fluorescence of cells exposed to 25 dyne/cm(2) versus control cells. This indicates that the observed FGF-2 release from human aortic smooth muscle cells is likely due to transient membrane disruption on initiation of flow.

  5. Detection, isolation, and capture of circulating breast cancer cells with photoacoustic flow cytometry

    Science.gov (United States)

    Bhattacharyya, Kiran; Njoroge, Martin; Goldschmidt, Benjamin S.; Gaffigan, Brian; Rood, Kyle; Viator, John A.

    2013-03-01

    According to the CDC, breast cancer is the most common cancer and the second leading cause of cancer related deaths among women. Metastasis, or the presence of secondary tumors caused by the spread of cancer cells via the circulatory or lymphatic systems, significantly worsens the prognosis of any breast cancer patient. In this study, a technique is developed to detect circulating breast cancer cells in human blood using a photoacoustic flow cytometry method. A Q-switched laser with a 5 ns pulse at 532 nm is used to interrogate thousands of cells with one pulse as they flow through the beam path. Cells which are pigmented, either naturally or artificially, emit an ultrasound wave as a result of the photoacoustic (PA) effect. Breast cancer cells are targeted with chromophores through immunochemistry in order to provide pigment. After which, the device is calibrated to demonstrate a single-cell detection limit. Cultured breast cancer cells are added to whole blood to reach a biologically relevant concentration of about 25-45 breast cancer cells per 1 mL of blood. An in vitro photoacoustic flow cytometer is used to detect and isolate these cells followed by capture with the use of a micromanipulator. This method can not only be used to determine the disease state of the patient and the response to therapy, it can also be used for genetic testing and in vitro drug trials since the circulating cell can be captured and studied.

  6. Detection and capture of breast cancer cells with photoacoustic flow cytometry

    Science.gov (United States)

    Bhattacharyya, Kiran; Goldschmidt, Benjamin S.; Viator, John A.

    2016-08-01

    According to the Centers for Disease Control and Prevention, breast cancer is the most common cancer and the second leading cause of cancer related deaths among women. Metastasis-the presence of secondary tumors caused by the spread of cancer cells via the circulatory or lymphatic systems-significantly worsens the prognosis of any breast cancer patient. A technique is developed to detect circulating breast cancer cells in human blood using a photoacoustic flow cytometry method. A Q-switched laser is used to interrogate thousands of blood cells with one pulse as they flow through the beam path. Cells that are optically absorbing, either naturally or artificially, emit an ultrasound wave as a result of the photoacoustic (PA) effect. Breast cancer cells are targeted with chromophores through immunochemistry in order to enhance optical absorption. After which, the PA cytometry device is calibrated to demonstrate the ability to detect single cells. Cultured breast cancer cells are added to whole blood to reach a biologically relevant concentration of about 25 to 45 breast cancer cells per 1 mL of blood. An in vitro PA flow cytometer is used to detect and isolate these cells followed by capture with the use of a micromanipulator. This method can not only be used to determine the disease state of the patient and the response to therapy but also it can be used for genetic testing and in vitro drug trials since the circulating cell can be captured and studied.

  7. Flow-system analysis of exfoliated pulmonary cells: results of initial characterization studies in hamsters

    Energy Technology Data Exchange (ETDEWEB)

    Steinkamp, J.A.; Hansen, K.M.; Wilson, J.S.; Salzman, G.C.

    1976-01-01

    This paper summarizes results of preliminary experiments to develop cytological and biochemical indicators for estimating damage to respiratory cells in test animals exposed by inhalation to toxic agents associated with nonnuclear energy production, the specific goal being the application of advanced multiparameter flow-systems technologies to the detection of early atypical cellular changes in lung epithelium. Normal Syrian hamster lung cell samples composed of histiocytes, leukocytes, macrophages, ciliated columnar cells, and epithelial cells were stained with fluorescent dyes specific for different biochemical parameters and were analyzed in liquid suspension as they flowed through a chamber intersecting a laser beam of exciting light. Multiple sensors measured the total or two-color fluorescence and light scatter on a cell-by-cell basis. Cellular parameters proportional to optical measurements (i.e., cell size, DNA content, total protein, nonspecific esterase activity, nuclear and cytoplasmic diameters) were displayed as frequency distribution histograms. Lung cell samples were also separated according to various cytological parameters and identified microscopically. The basic operating features of the methodology are discussed briefly, along with specific examples of preliminary results illustrating the initial characterization of exfoliated pulmonary cells from normal hamsters. As the flow technology is adapted further to the analysis of respiratory cells, measurements of changes in physical and biochemical properties as a function of exposure to toxic agents will be performed.

  8. Detection and capture of breast cancer cells with photoacoustic flow cytometry

    Science.gov (United States)

    Bhattacharyya, Kiran; Goldschmidt, Benjamin S.; Viator, John A.

    2016-01-01

    Abstract. According to the Centers for Disease Control and Prevention, breast cancer is the most common cancer and the second leading cause of cancer related deaths among women. Metastasis—the presence of secondary tumors caused by the spread of cancer cells via the circulatory or lymphatic systems—significantly worsens the prognosis of any breast cancer patient. A technique is developed to detect circulating breast cancer cells in human blood using a photoacoustic flow cytometry method. A Q-switched laser is used to interrogate thousands of blood cells with one pulse as they flow through the beam path. Cells that are optically absorbing, either naturally or artificially, emit an ultrasound wave as a result of the photoacoustic (PA) effect. Breast cancer cells are targeted with chromophores through immunochemistry in order to enhance optical absorption. After which, the PA cytometry device is calibrated to demonstrate the ability to detect single cells. Cultured breast cancer cells are added to whole blood to reach a biologically relevant concentration of about 25 to 45 breast cancer cells per 1 mL of blood. An in vitro PA flow cytometer is used to detect and isolate these cells followed by capture with the use of a micromanipulator. This method can not only be used to determine the disease state of the patient and the response to therapy but also it can be used for genetic testing and in vitro drug trials since the circulating cell can be captured and studied. PMID:27580367

  9. Development of a micro flow-through cell for high field NMR spectroscopy.

    Energy Technology Data Exchange (ETDEWEB)

    Alam, Todd Michael; McIntyre, Sarah K.

    2011-05-01

    A highly transportable micro flow-through detection cell for nuclear magnetic resonance (NMR) spectroscopy has been designed, fabricated and tested. This flow-through cell allows for the direct coupling between liquid chromatography (LC) and gel permeation chromatography (GPC) resulting in the possibility of hyphenated LC-NMR and GPC-NMR. The advantage of the present flow cell design is that it is independent and unconnected to the detection probe electronics, is compatible with existing commercial high resolution NMR probes, and as such can be easily implemented at any NMR facility. Two different volumes were fabricated corresponding to between {approx}3.8 and 10 {micro}L detection volume. Examples of the performance of the cell on different NMR instruments, and using different NMR detection probes were demonstrated.

  10. Flow fraction in charged rectangular microchannel to optimally design hydrodynamic filtration chip for cell sorting

    Science.gov (United States)

    Chun, Myung-Suk; Jeong, Sohyun; Kim, Jae Hun; Lee, Tae Seok

    2015-11-01

    Among the passive separations, hydrodynamic filtration (HDF) can perform the fractionation of cells or particles by selective extraction of streamlines controlled by the flow fraction at each branch. Only the stream near the sidewall enters the branches as the focusing, with the amount of fluid leaving the main channel being determined by the flow distribution related to the hydraulic flow resistances. Its understanding is important, but in-depth consideration has not been treated until now. The virtual boundary of the fluid layer should be first specified, and the parabolic velocity profile starts to form from the steady state flow with high Péclet numbers. We computed the 3-dimensional flow profile at the rectangular cross-section with any aspect ratios, by considering electrokinetic transport coupled with the Poisson-Boltzmann and Navier-Stokes equations. The chip was designed with the parameters rigorously determined by the complete analysis of laminar flow for flow fraction and complicated networks of main and multi-branched channels for cell sorting into the finite number of subpopulations. For potential applications to the precise sorting, our designed microfluidic chip can be validated by applying model cells consisting of heterogeneous subpopulations. Supported by the KIST Institutional Program (No. 2E25382).

  11. Tualang Honey Promotes Apoptotic Cell Death Induced by Tamoxifen in Breast Cancer Cell Lines

    Directory of Open Access Journals (Sweden)

    Nik Soriani Yaacob

    2013-01-01

    Full Text Available Tualang honey (TH is rich in flavonoids and phenolic acids and has significant anticancer activity against breast cancer cells comparable to the effect of tamoxifen (TAM, in vitro. The current study evaluated the effects of TH when used in combination with TAM on MCF-7 and MDA-MB-231 cells. We observed that TH promoted the anticancer activity of TAM in both the estrogen receptor-(ER-responsive and ER-nonresponsive human breast cancer cell lines. Flow cytometric analyses indicated accelerated apoptosis especially in MDA-MB-231 cells and with the involvement of caspase-3/7, -8 and -9 activation as shown by fluorescence microscopy. Depolarization of the mitochondrial membrane was also increased in both cell lines when TH was used in combination with TAM compared to TAM treatment alone. TH may therefore be a potential adjuvant to be used with TAM for reducing the dose of TAM, hence, reducing TAM-induced adverse effects.

  12. Identification of alpha beta and gamma delta T cell receptor-positive cells

    DEFF Research Database (Denmark)

    Geisler, C; Larsen, J K; Plesner, T

    1988-01-01

    distribution and function of these different T cells. In immunofluorescence studies gamma delta TCR+ cells have been identified as CD3+WT-31- or CD3+CD4-CD8- cells. However, this may not be the optimal procedure because gamma delta TCR+ cells are weakly WT-31+, and some are CD8+. The aim of this study...... was to evaluate a panel of monoclonal antibodies (MoAb) directed against different chains of the TCR-T3 complex for a more precise identification of alpha beta+ and gamma delta TCR+ cells in flow cytometric studies. We found that the MoAb anti-Ti-gamma A and delta-TCS-1, recognizing the TCR-gamma and the TCR...

  13. Classification of biological cells using a sound wave based flow cytometer

    Science.gov (United States)

    Strohm, Eric M.; Gnyawali, Vaskar; Van De Vondervoort, Mia; Daghighi, Yasaman; Tsai, Scott S. H.; Kolios, Michael C.

    2016-03-01

    A flow cytometer that uses sound waves to determine the size of biological cells is presented. In this system, a microfluidic device made of polydimethylsiloxane (PDMS) was developed to hydrodynamically flow focus cells in a single file through a target area. Integrated into the microfluidic device was an ultrasound transducer with a 375 MHz center frequency, aligned opposite the transducer was a pulsed 532 nm laser focused into the device by a 10x objective. Each passing cell was insonfied with a high frequency ultrasound pulse, and irradiated with the laser. The resulting ultrasound and photoacoustic waves from each cell were analyzed using signal processing methods, where features in the power spectra were compared to theoretical models to calculate the cell size. Two cell lines with different size distributions were used to test the system: acute myeloid leukemia cells (AML) and melanoma cells. Over 200 cells were measured using this system. The average calculated diameter of the AML cells was 10.4 +/- 2.5 μm using ultrasound, and 11.4 +/- 2.3 μm using photoacoustics. The average diameter of the melanoma cells was 16.2 +/- 2.9 μm using ultrasound, and 18.9 +/- 3.5 μm using photoacoustics. The cell sizes calculated using ultrasound and photoacoustic methods agreed with measurements using a Coulter Counter, where the AML cells were 9.8 +/- 1.8 μm and the melanoma cells were 16.0 +/- 2.5 μm. These results demonstrate a high speed method of assessing cell size using sound waves, which is an alternative method to traditional flow cytometry techniques.

  14. Confocal backscattering-based detection of leukemic cells in flowing blood samples.

    Science.gov (United States)

    Greiner, Cherry; Hunter, Martin; Rius, Francisca; Huang, Peter; Georgakoudi, Irene

    2011-10-01

    The prognostic value of assessing minimal residual disease (MRD) in leukemia has been established with advancements in flow cytometry and PCR. Nonetheless, these techniques are limited by high equipment costs, complex, and costly cell processing and the need for highly trained personnel. Here, we demonstrate the potential of exploiting differences in the relative intensities of backscattered light at three wavelengths to detect the presence of leukemic cells in samples containing varying mixtures of white blood cells (WBCs) and leukemic cells flowing through microfluidic channels. Using 405, 488, and 633 nm illumination, we identify distinct light scattering intensity distributions for Nalm-6 leukemic cells, normal mononuclear (PBMC) and polymorphonuclear (PMN) white blood cells and red blood cells. We exploit these differences to develop cell classification algorithms, whose performance is evaluated based on simultaneous acquisition of light scattering and fluorescence flow cytometry data. When this algorithm is used prospectively for the analysis of samples consisting of mixtures of PBMCs and leukemic cells, we achieve an average specificity and sensitivity of leukemic cell detection of 99.6 and 45.2%, respectively. When we consider samples that include leukemic cells along with PMNs and PBMCs, which can be acquired using a simple red blood cell lysis step following venipuncture, the specificity and sensitivity of the approach decreases to 91.6 and 39.5%, respectively. On the basis of the performance of these algorithms, we estimate that 42 or 71 μL of blood would be adequate to confirm the presence of leukemia at an 80% power level in samples containing 0.01% leukemia to either PBMCs or PBMCs and PMNs, respectively. Therefore, light scattering-based flow cytometry in a microfluidic platform could provide a low cost, highly portable, minimally invasive approach for detection and monitoring of leukemic patients. This could offer significant improvements

  15. Siglec-7 tetramers characterize B-cell subpopulations and leukemic blasts.

    Science.gov (United States)

    Gieseke, Friederike; Mang, Philippa; Viebahn, Susanne; Sonntag, Inga; Kruchen, Anne; Erbacher, Annika; Pfeiffer, Matthias; Handgretinger, Rupert; Müller, Ingo

    2012-08-01

    Cell surface glycosylation has important regulatory functions in the maturation, activation, and homeostasis of lymphocytes. The family of human sialic acid-binding immunoglobulin-like lectins (siglecs) comprises inhibitory as well as activating receptors intimately involved in the regulation of immune responses. Analyses of the interaction between siglecs and glycans are hampered by the low affinity of this interaction. Therefore, we expressed siglec-7 in eukaryotic cells, allowing for glycosylation, and oligomerized the protein in analogy to MHC tetramers. Using this tool, flow cytometric analysis of lymphocytes became possible. Sialic acid-dependent binding of siglec-7 tetramers was confirmed by glycan array analysis and loss of siglec tetramer binding after neuraminidase treatment of lymphocytes. In contrast to most lymphocyte subpopulations, which showed high siglec-7 ligand expression, B-cell subpopulations could be further subdivided according to different siglec-7 ligand expression levels. We also analyzed blasts from acute lymphoblastic leukemias of the B-cell lineage as well as the T-cell lineage, since malignant transformation is often associated with aberrant cell surface glycosylation. While pediatric T-ALL blasts highly expressed siglec-7 ligands, siglec-7 ligands were barely detectable on cALL blasts. Taken together, oligomerization of recombinant soluble siglec-7 enabled flow cytometric identification of physiologic lymphocyte subpopulations and malignant blasts. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Getting into the flow: Red cells go on a roll, two-component vesicles swing

    Science.gov (United States)

    Viallat, Annie; Dupire, Jules; Khelloufi, Kamel; Al Halifa, Al Hair; Adhesion and Inflammation Team

    2013-11-01

    Red blood cells are soft capsules. Under shear flow, their two known motions were ``tumbling'' and ``swinging-tank treading,'' depending on cell mechanics and flow conditions. We reveal new wobbling regimes, among which the ``rolling'' regime, where red cells move as wheels on a road. We show, by coupling two video-microscopy approaches providing multi-directional cell pictures that the orientation of cells flipping into the flow is determined by the shear rate. Rolling permits to avoid energetically costly cellular deformations and is a true signature of the cytoskeleton elasticity. We highlight two transient dynamics: an intermittent regime during the ``tank-treading-to-flipping'' transition and a Frisbee-like ``spinning'' regime during the ``rolling-to-tank-treading'' transition. We find that the biconcave red cell shape is very stable under moderate shear stresses, and we interpret this result in terms of shape memory and elastic buckling. Finally, we generate lipid vesicles with a shape memory by using two lipids with different bending rigidities. These vesicles swing in shear flow similarly to red blood cells but their non-axisymmetric stress-free shape changes the periodicity of the motion and induces specific features.

  17. Particle and Blood Cell Dynamics in Oscillatory Flows Final Report

    International Nuclear Information System (INIS)

    Restrepo, Juan M.

    2008-01-01

    Our aim has been to uncover fundamental aspects of the suspension and dislodgement of particles in wall-bounded oscillatory flows, in flows characterized by Reynolds numbers encompassing the situation found in rivers and near shores (and perhaps in some industrial processes). Our research tools are computational and our coverage of parameter space fairly broad. Computational means circumvent many complications that make the measurement of the dynamics of particles in a laboratory setting an impractical task, especially on the broad range of parameter space we plan to report upon. The impact of this work on the geophysical problem of sedimentation is boosted considerably by the fact that the proposed calculations can be considered ab-initio, in the sense that little to no modeling is done in generating dynamics of the particles and of the moving fluid: we use a three-dimensional Navier Stokes solver along with straightforward boundary conditions. Hence, to the extent that Navier Stokes is a model for an ideal incompressible isotropic Newtonian fluid, the calculations yield benchmark values for such things as the drag, buoyancy, and lift of particles, in a highly controlled environment. Our approach will be to make measurements of the lift, drag, and buoyancy of particles, by considering progressively more complex physical configurations and physics.

  18. Cyclic flow shop scheduling problem with two-machine cells

    Directory of Open Access Journals (Sweden)

    Bożejko Wojciech

    2017-06-01

    Full Text Available In the paper a variant of cyclic production with setups and two-machine cell is considered. One of the stages of the problem solving consists of assigning each operation to the machine on which it will be carried out. The total number of such assignments is exponential. We propose a polynomial time algorithm finding the optimal operations to machines assignment.

  19. Mechanisms of eosinophil adhesion to endothelial cells under flow conditions

    NARCIS (Netherlands)

    Ulfman, L.H.

    2002-01-01

    Eosinophils play an important role in allergic inflammatory diseases such as allergic asthma. Infiltrates of these cells are present in the interstitium and the lumen of the bronchi of asthmatic patients. Eosinophils must pass the endothelium to enter this site of inflammation. A widely accepted

  20. Pseudomonas aeruginosa and Saccharomyces cerevisiae Biofilm in Flow Cells

    DEFF Research Database (Denmark)

    Weiss Nielsen, Martin; Sternberg, Claus; Molin, Søren

    2011-01-01

    Many microbial cells have the ability to form sessile microbial communities defined as biofilms that have altered physiological and pathological properties compared to free living microorganisms. Biofilms in nature are often difficult to investigate and reside under poorly defined conditions(1). ...

  1. Measurement of bubble shape and size in bubbly flow structure for stagnant and pulsating liquid flow using an undivided electrochlorination cell and Telecentric Direct Image Method

    DEFF Research Database (Denmark)

    Andersen, Nikolaj; Stroe, Rodica-Elisabeta; Hedensted, Lau

    2016-01-01

    This study presents the measurement of shape and diameter of bubbles in different regions of the bubbly flow structure at the cathode for stagnant and pulsating liquid flow in a single undivided electrochlorination cell. The cell is filled with a dilute sodium chloride electrolyte solution...... is supported by an increase in fraction of total gas volume constituted by large bubbles. For pulsating liquid flow the mean bubble diameter is observed to remain constant around 35 μm when moving across the bubbly flow structure, which likewise is supported by the fraction of total gas volume investigations...

  2. Comparative exploration of multidimensional flow cytometry software: a model approach evaluating T cell polyfunctional behavior.

    Science.gov (United States)

    Spear, Timothy T; Nishimura, Michael I; Simms, Patricia E

    2017-08-01

    Advancement in flow cytometry reagents and instrumentation has allowed for simultaneous analysis of large numbers of lineage/functional immune cell markers. Highly complex datasets generated by polychromatic flow cytometry require proper analytical software to answer investigators' questions. A problem among many investigators and flow cytometry Shared Resource Laboratories (SRLs), including our own, is a lack of access to a flow cytometry-knowledgeable bioinformatics team, making it difficult to learn and choose appropriate analysis tool(s). Here, we comparatively assess various multidimensional flow cytometry software packages for their ability to answer a specific biologic question and provide graphical representation output suitable for publication, as well as their ease of use and cost. We assessed polyfunctional potential of TCR-transduced T cells, serving as a model evaluation, using multidimensional flow cytometry to analyze 6 intracellular cytokines and degranulation on a per-cell basis. Analysis of 7 parameters resulted in 128 possible combinations of positivity/negativity, far too complex for basic flow cytometry software to analyze fully. Various software packages were used, analysis methods used in each described, and representative output displayed. Of the tools investigated, automated classification of cellular expression by nonlinear stochastic embedding (ACCENSE) and coupled analysis in Pestle/simplified presentation of incredibly complex evaluations (SPICE) provided the most user-friendly manipulations and readable output, evaluating effects of altered antigen-specific stimulation on T cell polyfunctionality. This detailed approach may serve as a model for other investigators/SRLs in selecting the most appropriate software to analyze complex flow cytometry datasets. Further development and awareness of available tools will help guide proper data analysis to answer difficult biologic questions arising from incredibly complex datasets. © Society

  3. Identification of residual leukemic cells by flow cytometry in childhood B-cell precursor acute lymphoblastic leukemia - Verification of leukemic state by flow-sorting and molecular/cytogenetic methods

    DEFF Research Database (Denmark)

    Obro, Nina Friesgaard; Ryder, Lars Peter; Madsen, Hans Ole

    2012-01-01

    Reduction in minimal residual disease, measured by real-time quantitative PCR or flow cytometry, predicts prognosis in childhood B-cell precursor acute lymphoblastic leukemia. We explored whether cells reported as minimal residual disease by flow cytometry represent the malignant clone harboring...... immunophenotype and antigen modulation) that highlight important methodological pitfalls. These findings demonstrate that with sufficient experience, flow cytometry is reliable for minimal residual disease monitoring in B-cell precursor acute lymphoblastic leukemia, although rare cases require supplementary PCR...

  4. Pyrogallol, ROS generator inhibits As4.1 juxtaglomerular cells via cell cycle arrest of G2 phase and apoptosis

    International Nuclear Information System (INIS)

    Park, Woo Hyun; Han, Yong Hwan; Kim, Suhn Hee; Kim, Sung Zoo

    2007-01-01

    Pyrogallol as a catechin compound has been employed as an O 2 · - generator and often used to investigate the role of ROS in the biological system. Here, we investigated the in vitro effect of pyrogallol on cell growth, cell cycle and apoptosis in As4.1 juxtaglomerular cells. Dose-dependent inhibition of cell growth was observed with IC 50 of about 60 μM for 48 h using MTT assay. Pyrogallol (100 μM) did not alter intracellular H 2 O 2 level and catalase activity, but increased the intracellular O 2 · - level and decreased SOD activity in As4.1 cells. DNA flow cytometric analysis indicated that 50 and 100 μM pyrogallol significantly increased G2 phase cells as compared with those of pyrogallol-untreated cells. Also, pyrogallol induced apoptosis as evidenced by flow cytometric detection of sub-G1 DNA content, annexin V binding assay and DAPI staining. This apoptosis process was accompanied with the loss of mitochondrial transmembrane potential (ΔΨ m ), Bcl-2 decrease, caspase-3 activation and PARP cleavage. Pan caspase inhibitor (Z-VAD) could significantly rescue As4.1 cells from pyrogallol-induced cell death. But, the inhibitors of caspase-3, caspase-8, and caspase-9 did not prevent apoptotic events in pyrogallol-treated As4.1 cells. Taken together, we have demonstrated that an ROS inducer, pyrogallol inhibits the growth of As4.1 JG cells via cell cycle arrest and apoptosis, and suggest that the compound exhibits an anti-proliferative efficacy on these cells

  5. Hot gas flow cell for optical measurements on reactive gases

    DEFF Research Database (Denmark)

    Grosch, Helge; Fateev, Alexander; Nielsen, Karsten Lindorff

    2013-01-01

    was validated for high resolution measurements at temperatures of up to 800 K (527 degrees C) in the ultraviolet (UV) and infrared (IR) regions (190-20 000 nm). Verification of the gas temperature in the cell is provided by a thermocouple and emission/transmission measurements in the IR and UV regions. High......-resolution measurements are presented for the absorption cross-section of sulfur dioxide (SO2) in the UV range up to 773 K (500 degrees C)...

  6. Synergy of photoacoustic and fluorescence flow cytometry of circulating cells with negative and positive contrasts

    Science.gov (United States)

    Nedosekin, Dmitry A.; Sarimollaoglu, Mustafa; Galanzha, Ekaterina I.; Sawant, Rupa; Torchilin, Vladimir P.; Verkhusha, Vladislav V.; Ma, Jie; Frank, Markus H.; Biris, Alexandru S.; Zharov, Vladimir P.

    2012-01-01

    In vivo photoacoustic (PA) and fluorescence flow cytometry were previously applied separately using pulsed and continuous wave lasers respectively, and positive contrast detection mode only. This paper introduces a real-time integration of both techniques with positive and negative contrast modes using only pulsed lasers. Various applications of this new tool are summarized, including detection of liposomes loaded with Alexa-660 dye, red blood cells labeled with Indocyanine Green, B16F10 melanoma cells co-expressing melanin and green fluorescent protein (GFP), C8161-GFP melanoma cells targeted by magnetic nanoparticles, MTLn3 adenocarcinoma cells expressing novel near-infrared iRFP protein, and quantum dot-carbon nanotube conjugates. Negative contrast flow cytometry provided label-free detection of low absorbing or weakly fluorescent cells in blood absorption and autofluorescence background, respectively. The use of pulsed laser for time-resolved discrimination of objects with long fluorescence lifetime (e.g., quantum dots) from shorter autofluorescence background (e.g., blood plasma) is also highlighted in this paper. The supplementary nature of PA and fluorescence detection increased the versatility of the integrated method for simultaneous detection of probes and cells having various absorbing and fluorescent properties, and provided verification of PA data using a more established fluorescence based technique. The principles of integrated photoacoustic and fluorescence flow cytometry using positive contrast for detection of strongly absorbing and fluorescent cells and negative contrast for detection of weakly absorbing and fluorescent cells in blood absorption and autofluorescence background, respectively. PMID:22903924

  7. Integrating a dual-silicon photoelectrochemical cell into a redox flow battery for unassisted photocharging

    DEFF Research Database (Denmark)

    Liao, Shichao; Zong, Xu; Seger, Brian

    2016-01-01

    Solar rechargeable flow cells (SRFCs) provide an attractive approach for in situ capture and storage of intermittent solar energy via photoelectrochemical regeneration of discharged redox species for electricity generation. However, overall SFRC performance is restricted by inefficient photoelect......Solar rechargeable flow cells (SRFCs) provide an attractive approach for in situ capture and storage of intermittent solar energy via photoelectrochemical regeneration of discharged redox species for electricity generation. However, overall SFRC performance is restricted by inefficient...... photoelectrochemical reactions. Here we report an efficient SRFC based on a dual-silicon photoelectrochemical cell and a quinone/bromine redox flow battery for in situ solar energy conversion and storage. Using narrow bandgap silicon for efficient photon collection and fast redox couples for rapid interface charge...

  8. Bedrock refractive-flow cells: A passive treatment analog to funnel-and-gate

    International Nuclear Information System (INIS)

    Dick, V.; Edwards, D.

    1997-01-01

    Funnel-and-gate technology provides a mechanism to passively treat groundwater contaminant plumes, but depends on placement of a sufficient barrier (open-quotes funnelclose quotes) in the plume flow path to channel the plume to a pass-through treatment zone (open-quotes gateclose quotes). Conventional barrier technologies limit funnel-and-gate deployment to unconsolidated overburden applications. A method has been developed which allows similar passive treatment to be applied to bedrock plumes. Rather than use barriers as the funnel, the method uses engineered bedrock zones, installed via precision blasting or other means, to refract groundwater flow along a preferred path to treatment (gate). The method requires orienting the refractive cell based on the Tangent Law and extending refractive cell limbs down gradient of the gate to disperse head and control flow. A typical Refractive-Flow cell may be open-quotes Yclose quotesshaped, with each limb 3-10 ft [1-3 m] wide and several tens to a few hundred feet [10 - 100 m] in length. Treatment takes place at the center of the X. MODFLOW modeling has been used to successfully simulate desired flow. Engineered blasting has been used at full scale application to create bedrock rubble zones for active collection/flow control for several years. The method provides a previously unavailable method to passively treat contaminated groundwater in bedrock at low cost

  9. Two-dimensional model of flows and interface instability in aluminum reduction cells

    Science.gov (United States)

    Zikanov, Oleg; Sun, Haijun; Ziegler, Donald

    2003-11-01

    We derive a two-dimensional model for the melt flows and interface instability in aluminum reduction cells. The model is based on the de St. Venant shallow water equations and incorporates the essential features of the system such as the magnetohydrodynamic instability mechanism and nonlinear coupling between the flows and interfacial waves. The model is applied to verify a recently proposed theory that explains the instability through the interaction between perturbations of horizontal electric currents in the aluminum layer and the imposed vertical magnetic field. We investigate the role of other factors, in particular, background melt flows and magnetic field perturbations.

  10. Diagnosis of Plasma Cell Dyscrasias and Monitoring of Minimal Residual Disease by Multiparametric Flow Cytometry

    Science.gov (United States)

    Soh, Kah Teong; Tario, Joseph D.; Wallace, Paul K.

    2018-01-01

    Synopsis Plasma cell dyscrasia (PCD) is a heterogeneous disease which has seen a tremendous change in outcomes due to improved therapies. Over the last few decades, multiparametric flow cytometry has played an important role in the detection and monitoring of PCDs. Flow cytometry is a high sensitivity assay for early detection of minimal residual disease (MRD) that correlates well with progression-free survival and overall survival. Before flow cytometry can be effectively implemented in the clinical setting sample preparation, panel configuration, analysis, and gating strategies must be optimized to ensure accurate results. Current consensus methods and reporting guidelines for MRD testing are discussed. PMID:29128071

  11. Surfactant functionalization induces robust, differential adhesion of tumor cells and blood cells to charged nanotube-coated biomaterials under flow.

    Science.gov (United States)

    Mitchell, Michael J; Castellanos, Carlos A; King, Michael R

    2015-07-01

    The metastatic spread of cancer cells from the primary tumor to distant sites leads to a poor prognosis in cancers originating from multiple organs. Increasing evidence has linked selectin-based adhesion between circulating tumor cells (CTCs) and endothelial cells of the microvasculature to metastatic dissemination, in a manner similar to leukocyte adhesion during inflammation. Functionalized biomaterial surfaces hold promise as a diagnostic tool to separate CTCs and potentially treat metastasis, utilizing antibody and selectin-mediated interactions for cell capture under flow. However, capture at high purity levels is challenged by the fact that CTCs and leukocytes both possess selectin ligands. Here, a straightforward technique to functionalize and alter the charge of naturally occurring halloysite nanotubes using surfactants is reported to induce robust, differential adhesion of tumor cells and blood cells to nanotube-coated surfaces under flow. Negatively charged sodium dodecanoate-functionalized nanotubes simultaneously enhanced tumor cell capture while negating leukocyte adhesion, both in the presence and absence of adhesion proteins, and can be utilized to isolate circulating tumor cells regardless of biomarker expression. Conversely, diminishing nanotube charge via functionalization with decyltrimethylammonium bromide both abolished tumor cell capture while promoting leukocyte adhesion. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Counter-flow elutriation of clinical peripheral blood mononuclear cell concentrates for the production of dendritic and T cell therapies

    OpenAIRE

    Stroncek, David F; Fellowes, Vicki; Pham, Chauha; Khuu, Hanh; Fowler, Daniel H; Wood, Lauren V; Sabatino, Marianna

    2014-01-01

    Introduction Peripheral blood mononuclear cells (PBMC) concentrates collected by apheresis are frequently used as starting material for cellular therapies, but the cell of interest must often be isolated prior to initiating manufacturing. Study design and methods The results of enriching 59 clinical PBMC concentrates for monocytes or lymphocytes from patients with solid tumors or multiple myeloma using a commercial closed system semi-automated counter-flow elutriation instrument (Elutra, Teru...

  13. Effect of Flow on Cultured Cell at Micro-Pattern of Ridge Lines

    Directory of Open Access Journals (Sweden)

    Haruka Hino

    2017-10-01

    Full Text Available A flow channel with a micro-pattern of ridge lines of a scaffold has been designed to study quantitatively the effect of flow on an oriented cell in vitro. The lines of parallel micro ridges (0.001 mm height, 0.003 mm width, and 0.003 mm interval are made by the lithography technique on the lower surface of the channel as the scaffold to make orientation of each cell. Variation is made about the angle between the longitudinal direction of the ridge line and the direction of the flow: zero, 0.79 and 1.6 rad. The suspension of C2C12 (mouse myoblast cell line was injected to the channel, and incubated for two hours on the micro ridges before the flow test for four hours. The flow rate of 3/hour is controlled by a syringe pump to make variation of the wall shear stress of < 3 Pa. The action of each cell adhered on the micro pattern was analyzed at the time lapse images. The experimental results show that both the migration and the deformation of each myoblast along the micro ridge are restricted by the wall shear stress higher than 3 Pa.

  14. Evaluation of cell cycle changes activated by the administration of 177Lu-DOTA-antiCD20

    International Nuclear Information System (INIS)

    Ramos B, J. C.

    2016-01-01

    In the present project, cytometric evaluation of cell cycle changes induced by the 177 Lu-DOTA-antiCD20 thermostatic radiopharmaceutical was performed, in which a cell culture of Raji cells from Burkitts lymphoma were used, which are CD20+; for flow cytometry different parameters were measured in which the cells were synchronized in G0/G1 and G2/M, to calculate the dose to nucleus that were given to the cells the Monte Carlo method was used at a dose interval from 1 to 5 Gy. The purpose of this work is to be able to observe by flow cytometry the arrest in the cell cycle with a lower dose interval than the one applied in other papers. (Author)

  15. Effect of decreasing electrical resistance in Characeae cell membranes caused by the flow of alternating current

    Directory of Open Access Journals (Sweden)

    Edward Śpiewla

    2014-01-01

    Full Text Available By means of the techniques of external electrodes and microelectrodes, it was found that evanescent flow of an alternating current through plasmalemma of Characeae cells neutralises oscillatory change in their electrical resistance and reversibly diminishes its value. This effect is particularly significant in the case of "high resistance cells", but it weakens with increasing temperature. The value of the estimated activation energy indicates that, after flow of the alternating current through the membrane, a rapid increase in the conductivity may be caused by an increase in conductivity of potassium channels. This result seems to support the hypothesis of electroconformational feedback.

  16. Effects of Radix Adenophorae and Cyclosporine A on an OVA-Induced Murine Model of Asthma by Suppressing to T Cells Activity, Eosinophilia, and Bronchial Hyperresponsiveness

    Directory of Open Access Journals (Sweden)

    Seong-Soo Roh

    2008-01-01

    Full Text Available The present study is performed to investigate the inhibitory effects of Radix Adenophorae extract (RAE on ovalbumin-induced asthma murine model. To study the anti-inflammatory and antiasthmatic effects of RAE, we examined the development of pulmonary eosinophilic inflammation and inhibitory effects of T cells in murine by RAE and cyclosporine A (CsA. We examined determination of airway hyperresponsiveness, flow cytometric analysis (FACS, enzyme-linked immunosorbent assay (ELISA, quantitative real time (PCR, hematoxylin-eosin staining, and Masson trichrome staining in lung tissue, lung weight, total cells, and eosinophil numbers in lung tissue. We demonstrated how RAE suppressed development on inflammation and decreased airway damage.

  17. Reconstitution of Scid mice with CD4+CD25- T cells leads to rapid colitis: an improved model for pharmacologic testing

    DEFF Research Database (Denmark)

    Kjellev, Stine; Lundsgaard, Dorthe; Poulsen, Steen Seier

    2006-01-01

    was paralleled by increased fecal soluble tumor necrosis factor receptor II content. Cytokines in colonic tissue homogenates exhibited a Th1-like profile. We conclude that adoptive transfer of CD4+CD25- T cells results in colitis resembling IBD with a rapid onset and limited variability between individuals....... Purification of CD4+CD25- T cells is a simple procedure, and does not require flow-cytometric sorting. Fecal consistency score and colonic weight:length ratio are readily measurable and consistent disease parameters. This model is thus highly suitable for pharmacological testing of intervention strategies....

  18. Isolation of circulating tumor cells using photoacoustic flowmetry and two phase flow

    Science.gov (United States)

    O'Brien, Christine M.; Rood, Kyle D.; Gupta, Sagar K.; Mosley, Jeffrey D.; Goldschmidt, Benjamin S.; Sharma, Nikhilesh; Sengupta, Shramik; Viator, John A.

    2011-03-01

    Melanoma is the deadliest form of skin cancer, yet current diagnostic methods are inadequately sensitive. Patients must wait until secondary tumors form before malignancy can be diagnosed and treatment prescribed. Detection of cells that have broken off the original tumor and flow through the blood or lymph system can provide data for diagnosing and monitoring cancer. Our group utilizes the photoacoustic effect to detect metastatic melanoma cells, which contain the pigmented granule melanin. As a rapid laser pulse irradiates melanoma, the melanin undergoes thermo-elastic expansion and ultimately creates a photoacoustic wave. Thus, melanoma patient's blood samples can be enriched, leaving the melanoma in a white blood cell (WBC) suspension. Irradiated melanoma cells produce photoacoustic waves, which are detected with a piezoelectric transducer, while the optically transparent WBCs create no signals. Here we report an isolation scheme utilizing two-phase flow to separate detected melanoma from the suspension. By introducing two immiscible fluids through a t-junction into one flow path, the analytes are compartmentalized. Therefore, the slug in which the melanoma cell is located can be identified and extracted from the system. Two-phase immiscible flow is a label free technique, and could be used for other types of pathological analytes.

  19. Experimental and numerical investigations of fluid flow for optimized in vitro stem cell loading in xenografts

    Directory of Open Access Journals (Sweden)

    Ott Robert

    2017-09-01

    Full Text Available In dentofacial surgery, augmentation procedures employing xenografts have become a reliable treatment. Recent studies, however, have shown significant enhance-ments of the in vivo bone tissue augmentation using mesenchymal stem cells loaded into bone grafts. We conducted experimental and numerical investigations in flow perfusion systems to determine flow conditions which allow for homogenous stem cell distribution in BioOss Block (Geistlich Pharma AG, Switzerland xenografts. Pressure gradient-velocity characteristics and flow distributions were investigated experimentally and numerically at steady state flow conditions with Reynolds numbers (Re ranging from 0.01 ≤ Re ≤ 0.40. Distilled water at 20°C with a dynamic viscosity of 1.002 mPa.s and a density of 998 kg/m3 was used. The geometry utilized in three-dimensional computa-tional fluid dynamics (CFD simulation was obtained by means of micro-computed tomography (μCT. Results of CFD analysis are in good accordance with experimental data. The comparison of the pressure gradient-velocity characteris-tics for experimental and numerical data yields a relative error of 3.6%. According to Darcy’s law for creeping fluid flow the experimentally determined permeability is 2.55.10-9 m2. Moreover, numerical flow distribution analysis shows an increasingly heterogenic streamline distribution for increasing Reynolds numbers. Experimentally validated CFD simulations introduced in this study provide a tool to assess optimal flow conditions for a homogenous stem cell distribution in perfusion flow systems.

  20. Improved and Reproducible Flow Cytometry Methodology for Nuclei Isolation from Single Root Meristem

    Directory of Open Access Journals (Sweden)

    Thaís Cristina Ribeiro Silva

    2010-01-01

    Full Text Available Root meristems have increasingly been target of cell cycle studies by flow cytometric DNA content quantification. Moreover, roots can be an alternative source of nuclear suspension when leaves become unfeasible and for chromosome analysis and sorting. In the present paper, a protocol for intact nuclei isolation from a single root meristem was developed. This proceeding was based on excision of the meristematic region using a prototypical slide, followed by short enzymatic digestion and mechanical isolation of nuclei during homogenization with a hand mixer. Such parameters were optimized for reaching better results. Satisfactory nuclei amounts were extracted and analyzed by flow cytometry, producing histograms with reduced background noise and CVs between 3.2 and 4.1%. This improved and reproducible technique was shown to be rapid, inexpensive, and simple for nuclear extraction from a single root tip, and can be adapted for other plants and purposes.

  1. Study of Paclitaxel-Treated HeLa Cells by Differential Electrical Impedance Flow Cytometry

    DEFF Research Database (Denmark)

    Kirkegaard, Julie; Clausen, Casper Hyttel; Rodriguez-Trujíllo, Romén

    2014-01-01

    This work describes the electrical investigation of paclitaxel-treated HeLa cells using a custom-made microfluidic biosensor for whole cell analysis in continuous flow. We apply the method of differential electrical impedance spectroscopy to treated HeLa cells in order to elucidate the changes...... in electrical properties compared with non-treated cells. We found that our microfluidic system was able to distinguish between treated and non-treated cells. Furthermore, we utilize a model for electrical impedance spectroscopy in order to perform a theoretical study to clarify our results. This study focuses...... on investigating the changes in the electrical properties of the cell membrane caused by the effect of paclitaxel. We observe good agreement between the model and the obtained results. This establishes the proof-of-concept for the application in cell drug therapy....

  2. Structures, Compositions, and Activities of Live Shewanella Biofilms Formed on Graphite Electrodes in Electrochemical Flow Cells.

    Science.gov (United States)

    Kitayama, Miho; Koga, Ryota; Kasai, Takuya; Kouzuma, Atsushi; Watanabe, Kazuya

    2017-09-01

    An electrochemical flow cell equipped with a graphite working electrode (WE) at the bottom was inoculated with Shewanella oneidensis MR-1 expressing an anaerobic fluorescent protein, and biofilm formation on the WE was observed over time during current generation at WE potentials of +0.4 and 0 V (versus standard hydrogen electrodes), under electrolyte-flow conditions. Electrochemical analyses suggested the presence of unique electron-transfer mechanisms in the +0.4-V biofilm. Microscopic analyses revealed that, in contrast to aerobic biofilms, current-generating biofilm (at +0.4 V) was thin and flat (∼10 μm in thickness), and cells were evenly and densely distributed in the biofilm. In contrast, cells were unevenly distributed in biofilm formed at 0 V. In situ fluorescence staining and biofilm recovery experiments showed that the amounts of extracellular polysaccharides (EPSs) in the +0.4-V biofilm were much smaller than those in the aerobic and 0-V biofilms, suggesting that Shewanella cells suppress the production of EPSs at +0.4 V under flow conditions. We suggest that Shewanella cells perceive electrode potentials and modulate the structure and composition of biofilms to efficiently transfer electrons to electrodes. IMPORTANCE A promising application of microbial fuel cells (MFCs) is to save energy in wastewater treatment. Since current is generated in these MFCs by biofilm microbes under horizontal flows of wastewater, it is important to understand the mechanisms for biofilm formation and current generation under water-flow conditions. Although massive work has been done to analyze the molecular mechanisms for current generation by model exoelectrogenic bacteria, such as Shewanella oneidensis , limited information is available regarding the formation of current-generating biofilms over time under water-flow conditions. The present study developed electrochemical flow cells and used them to examine the electrochemical and structural features of current

  3. An assessment of the energetic flows in a commercial PEM fuel-cell system

    International Nuclear Information System (INIS)

    Jovan, Vladimir; Perne, Matija; Petrovcic, Janko

    2010-01-01

    Some primary issues have not yet been fully investigated on the way towards the commercialization of fuel-cell-based systems (FCS), e.g., their actual efficiency, reliability, safety, degradation, maintainability, etc. This article deals with an estimation of the real energetic flows and the corresponding electrical efficiency of a commercial proton-exchange-membrane fuel-cell hydrogen-fed generator set (PEMFCS). The fuel-cell power system considered here is planned to be the source of both electrical and thermal energy in a mobile dwelling container unit with in-built fuel-cell-based cogeneration system, and for the design of a cogeneration unit the actual amount of disposable energy from the PEMFC unit should be estimated. The assessment of the actual energetic flows, the disposable energy and the consequent electrical efficiency of the case-study PEMFCS is carried out using commercial technical data for the PEMFCS.

  4. Mass transport aspects of polymer electrolyte fuel cells under two-phase flow conditions

    Energy Technology Data Exchange (ETDEWEB)

    Kramer, D.

    2007-03-15

    This well-illustrated, comprehensive dissertation by Dr. Ing. Denis Kramer takes an in-depth look at polymer electrolyte fuel cells (PEFC) and the possibilities for their application. First of all, the operating principles of polymer electrolyte fuel cells are described and discussed, whereby thermodynamics aspects and loss mechanisms are examined. The mass transport diagnostics made with respect to the function of the cells are discussed. Field flow geometry, gas diffusion layers and, amongst other things, liquid distribution, the influence of flow direction and the low-frequency behaviour of air-fed PEFCs are discussed. Direct methanol fuel cells are examined, as are the materials chosen. The documentation includes comprehensive mathematical and graphical representations of the mechanisms involved.

  5. Flow Cytometry Analysis of Peripheral Blood B Cell Distribution of Patients with Multiple Sclerosis

    Directory of Open Access Journals (Sweden)

    Vuslat Yılmaz

    2017-12-01

    Full Text Available Objective: Multiple sclerosis (MS is a central nervous system (CNS disease characterized by autoimmune inflammation and neurodegeneration. Damage to the CNS is thought to be mediated predominantly by activated pro-inflammatory T cells and antibody secreting B cells. Strong evidence of B cell functions in MS pathogenesis has come from trials of B cell- depleting treatment. In this study, the peripheral blood frequencies of B cell subsets were measured using flow cytometry in patients to determine the disease-specific B cell differences that might be associated with the evolution to progressive forms of MS. Materials and Methods: Peripheral blood mononuclear cells were separated from patients and healthy controls [relapsing-remitting MS (RRMS and secondary progressive MS (SPMS]. Cells were stained with anti-human monoclonal antibodies (CD19-APC, CD27-FITC, IgD-APC/Cy7, CD138-PE, CD24-PerCP and CD38-Alexa fluor 700, and analyzed using flow cytometry Results: There were no significant differences between the MS group and healthy controls by means of peripheral blood frequencies of B cells, immature, naïve, classic memory, plasma, plasmablasts, and regulatory B cells. Only higher naïve B cell frequency tendency was determined in patients with RRMS as compared with patients with SPMS and healthy controls. Conclusion: Peripheral blood B cell subset measurements are not likely to be used as a biomarker for prediction of disease progression. Although B cells have a well-known pathogenic significance, B cell population alterations do not occur during the progression of the disease

  6. Measuring cell cycle progression kinetics with metabolic labeling and flow cytometry.

    Science.gov (United States)

    Fleisig, Helen; Wong, Judy

    2012-05-22

    Precise control of the initiation and subsequent progression through the various phases of the cell cycle are of paramount importance in proliferating cells. Cell cycle division is an integral part of growth and reproduction and deregulation of key cell cycle components have been implicated in the precipitating events of carcinogenesis. Molecular agents in anti-cancer therapies frequently target biological pathways responsible for the regulation and coordination of cell cycle division. Although cell cycle kinetics tend to vary according to cell type, the distribution of cells amongst the four stages of the cell cycle is rather consistent within a particular cell line due to the consistent pattern of mitogen and growth factor expression. Genotoxic events and other cellular stressors can result in a temporary block of cell cycle progression, resulting in arrest or a temporary pause in a particular cell cycle phase to allow for instigation of the appropriate response mechanism. The ability to experimentally observe the behavior of a cell population with reference to their cell cycle progression stage is an important advance in cell biology. Common procedures such as mitotic shake off, differential centrifugation or flow cytometry-based sorting are used to isolate cells at specific stages of the cell cycle. These fractionated, cell cycle phase-enriched populations are then subjected to experimental treatments. Yield, purity and viability of the separated fractions can often be compromised using these physical separation methods. As well, the time lapse between separation of the cell populations and the start of experimental treatment, whereby the fractionated cells can progress from the selected cell cycle stage, can pose significant challenges in the successful implementation and interpretation of these experiments. Other approaches to study cell cycle stages include the use of chemicals to synchronize cells. Treatment of cells with chemical inhibitors of key

  7. Casticin impairs cell growth and induces cell apoptosis via cell cycle arrest in human oral cancer SCC-4 cells.

    Science.gov (United States)

    Chou, Guan-Ling; Peng, Shu-Fen; Liao, Ching-Lung; Ho, Heng-Chien; Lu, Kung-Wen; Lien, Jin-Cherng; Fan, Ming-Jen; La, Kuang-Chi; Chung, Jing-Gung

    2018-02-01

    Casticin, a polymethoxyflavone, present in natural plants, has been shown to have biological activities including anti-cancer activities. Herein, we investigated the anti-oral cancer activity of casticin on SCC-4 cells in vitro. Viable cells, cell cycle distribution, apoptotic cell death, reactive oxygen species (ROS) production, and Ca 2+ production, levels of ΔΨ m and caspase activity were measured by flow cytometric assay. Cell apoptosis associated protein expressions were examined by Western blotting and confocal laser microscopy. Results indicated that casticin induced cell morphological changes, DNA condensation and damage, decreased the total viable cells, induced G 2 /M phase arrest in SCC-4 cells. Casticin promoted ROS and Ca 2+ productions, decreases the levels of ΔΨ m , promoted caspase-3, -8, and -9 activities in SCC-4 cells. Western blotting assay demonstrated that casticin affect protein level associated with G2/M phase arrest and apoptosis. Confocal laser microscopy also confirmed that casticin increased the translocation of AIF and cytochrome c in SCC-4 cells. In conclusion, casticin decreased cell number through G 2 /M phase arrest and the induction of cell apoptosis through caspase- and mitochondria-dependent pathways in SCC-4 cells. © 2017 Wiley Periodicals, Inc.

  8. Automated Blood Sample Preparation Unit (ABSPU) for Portable Microfluidic Flow Cytometry.

    Science.gov (United States)

    Chaturvedi, Akhil; Gorthi, Sai Siva

    2017-02-01

    Portable microfluidic diagnostic devices, including flow cytometers, are being developed for point-of-care settings, especially in conjunction with inexpensive imaging devices such as mobile phone cameras. However, two pervasive drawbacks of these have been the lack of automated sample preparation processes and cells settling out of sample suspensions, leading to inaccurate results. We report an automated blood sample preparation unit (ABSPU) to prevent blood samples from settling in a reservoir during loading of samples in flow cytometers. This apparatus automates the preanalytical steps of dilution and staining of blood cells prior to microfluidic loading. It employs an assembly with a miniature vibration motor to drive turbulence in a sample reservoir. To validate performance of this system, we present experimental evidence demonstrating prevention of blood cell settling, cell integrity, and staining of cells prior to flow cytometric analysis. This setup is further integrated with a microfluidic imaging flow cytometer to investigate cell count variability. With no need for prior sample preparation, a drop of whole blood can be directly introduced to the setup without premixing with buffers manually. Our results show that integration of this assembly with microfluidic analysis provides a competent automation tool for low-cost point-of-care blood-based diagnostics.

  9. Quantitative assessment of limb blood flow using Tc-99m labeled red blood cells

    International Nuclear Information System (INIS)

    Itoh, Kazuo; Shougase, Takashi; Kawamura, Naoyuki; Tsukamoto, Eriko; Nakada, Kunihiro; Sakuma, Makoto; Furudate, Masayori

    1987-01-01

    A quantitative assessment of limb blood flow using a non-diffusible radioindicator, Tc-99m labeled red blood cells, was reported. This was an application of venous occlusion plethysmography using radionuclide which was originally proposed by M. Fukuoka et al. The peripheral blood flow (mean ± s.e.) of 30 legs in a normal control group was 1.87 ± 0.08 ml/100 ml/min. In heart diseases (46 legs), it was 1.49 ± 0.13 ml/100 ml/min. The limb blood flow between a control group and heart diseases was statistically significant (p < 0.01) in the t-test. The peripheral blood flow at rest between diseased legs and normal legs in occlusive arterial disorders was also statistically significant (p < 0.01) in a paired t-test. RAVOP was done after the completion of objective studies such as radionuclide angiography or ventriculography. Technique and calculation of a blood flow were very easy and simple. RAVOP study which was originally proposed by Fukuoka et al. was reappraised to be hopeful for quantitative measurement of limb blood flow as a non-invasive technique using Tc-99m labeled red blood cells. (author)

  10. Peripheral blood mononuclear cells analysis in microfluidic flow by coherent imaging tools

    Science.gov (United States)

    Dannhauser, David; Rossi, Domenico; Memmolo, Pasquale; Causa, Filippo; Finizio, Andrea; Ferraro, Pietro; Netti, Paolo A.

    2017-06-01

    Cell of human blood stream are divided into two groups: Red Blood Cells (RBC) and White Blood Cells (WBC). RBC have a peculiar biconcave disk shape and they are responsible for the delivering of O2 and CO2 through the body. WBC are a more widespread class of cell ensuring immunity against pathogens. They can be divided in two main classes: granulocyte cells and A-granulocyte cells. Neutrophils, basophils and eosinophils belong to the granulocyte cell class, while lymphocytes and monocytes belong to A-granulocyte. Both in RBC and WBC, the intrinsic physical properties of a cell are indicators of cell condition and, furthermore, of the overall human body state. Thus, the accurate comprehension of the physiological structure of WBCs is fundamental to recognize diseases. Here we show the possibility to simple and straightforwardly characterize the physical properties of individual RBC and mononuclear WBC in a microfluidic context, using a wide angle light scattering apparatus and a corresponding theoretical simulation of Optical Signature (OS). A non-Newtonian polymer alignment solution for cell is used to ensure an individual cell alignment in the microfluidic flow, thus permitting a precise investigation. Additionally, Quantitative Phase Imaging (QPI) holographic measurements are performed to estimate cell morphometric features, such as their refractive index. We analyzed more than 200 WBCs and 100 RBCs of three different probands. Results showed distinct cell populations according to their measured dimensions and shape, which can be associated to the presence of RBC, lymphocytes and monocytes.

  11. Numerical Analysis of Hydrodynamic Flow in Microfluidic Biochip for Single-Cell Trapping Application

    Directory of Open Access Journals (Sweden)

    Amelia Ahmad Khalili

    2015-11-01

    Full Text Available Single-cell analysis has become the interest of a wide range of biological and biomedical engineering research. It could provide precise information on individual cells, leading to important knowledge regarding human diseases. To perform single-cell analysis, it is crucial to isolate the individual cells before further manipulation is carried out. Recently, microfluidic biochips have been widely used for cell trapping and single cell analysis, such as mechanical and electrical detection. This work focuses on developing a finite element simulation model of single-cell trapping system for any types of cells or particles based on the hydrodynamic flow resistance (Rh manipulations in the main channel and trap channel to achieve successful trapping. Analysis is carried out using finite element ABAQUS-FEA™ software. A guideline to design and optimize single-cell trapping model is proposed and the example of a thorough optimization analysis is carried out using a yeast cell model. The results show the finite element model is able to trap a single cell inside the fluidic environment. Fluid’s velocity profile and streamline plots for successful and unsuccessful single yeast cell trapping are presented according to the hydrodynamic concept. The single-cell trapping model can be a significant important guideline in designing a new chip for biomedical applications.

  12. A modular segmented-flow platform for 3D cell cultivation.

    Science.gov (United States)

    Lemke, Karen; Förster, Tobias; Römer, Robert; Quade, Mandy; Wiedemeier, Stefan; Grodrian, Andreas; Gastrock, Gunter

    2015-07-10

    In vitro 3D cell cultivation is promised to equate tissue in vivo more realistically than 2D cell cultivation corresponding to cell-cell and cell-matrix interactions. Therefore, a scalable 3D cultivation platform was developed. This platform, called pipe-based bioreactors (pbb), is based on the segmented-flow technology: aqueous droplets are embedded in a water-immiscible carrier fluid. The droplet volumes range from 60 nL to 20 μL and are used as bioreactors lined up in a tubing like pearls on a string. The modular automated platform basically consists of several modules like a fluid management for a high throughput droplet generation for self-assembly or scaffold-based 3D cell cultivation, a storage module for incubation and storage, and an analysis module for monitoring cell aggregation and proliferation basing on microscopy or photometry. In this report, the self-assembly of murine embryonic stem cells (mESCs) to uniformly sized embryoid bodies (EBs), the cell proliferation, the cell viability as well as the influence on the cell differentiation to cardiomyocytes are described. The integration of a dosage module for medium exchange or agent addition will enable pbb as long-term 3D cell cultivation system for studying stem cell differentiation, e.g. cardiac myogenesis or for diagnostic and therapeutic testing in personalized medicine. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Ligament flow during drop-on-demand inkjet printing of bioink containing living cells

    Science.gov (United States)

    Zhang, Mengyun; Krishnamoorthy, Srikumar; Song, Hongtao; Zhang, Zhengyi; Xu, Changxue

    2017-03-01

    Organ printing utilizes tissue spheroids or filaments as building blocks to fabricate three-dimensional (3D) functional tissues and organs based on a layer-by-layer manufacturing mechanism. These fabricated tissues and organs are envisioned as alternatives to replace the damaged human tissues and organs, which is emerging as a promising solution to solve the organ donor shortage problem being faced all over the world. Inkjetting, one of the key technologies in organ printing, has been widely developed because of its moderate fabrication cost, good process controllability, and scale-up potentials. There are several key steps towards inkjet-based organ printing: generation of droplets from bioink, fabrication of 3D cellular structures, and post-printing tissue fusion and maturation. The droplet formation process is the first step, affecting the overall feasibility of the envisioned organ printing technology. This paper focuses on the ligament flow of the droplet formation process during inkjet printing of bioink containing living cells and its corresponding effect on post-printing cell viability and cell distribution. It is found that (1) two types of ligament flow are observed: at 30 V (Type I), the ligament flow has two different directions at the locations near the nozzle orifice and the forming droplet; at 60 V (Type II), the ligament flow directions are the same at both locations; (2) compared to Type II, fewer cells are ejected into the primary droplets in Type I, because some cells move back into the nozzle driven by the ligament flow in the positive z direction; and (3) cell viability in both Type I and Type II is around 90% without a significant difference. The resulting knowledge will benefit precise control of printing dynamics during inkjet printing of viscoelastic bioink for 3D biofabrication applications.

  14. In vitro and in vivo evaluation of the indoloquinone EO-9 (NSC 382 459) against human small cell carcinoma of the lung

    DEFF Research Database (Denmark)

    Roed, H; Aabo, K; Vindeløv, L

    1989-01-01

    As the indoloquinone EO-9 has previously shown activity in several tumor model systems it was evaluated against four human small cell lung cancer cell lines by the clonogenic assay. In two cell lines (Nyh and Tol), exponential dose-response curves were achieved with both 1 h and continuous exposure......, whereas no cell kill was obtained in the other two cell lines (69 and 592) when tested with 1 h incubation up to 0.25 microgram/ml. When the cells were exposed to drug in vitro, flow cytometric DNA analysis showed perturbations in the cell cycle distribution of the most sensitive cell line (Tol......) at a lower EO-9 concentration than in the less sensitive cel line (592). This in vitro predicted difference in EO-9 sensitivity between two of the cell lines (592 and Tol) was confirmed when the cell lines were heterotransplanted to nude mice....

  15. Effects of microRNA-221/222 on cell proliferation and apoptosis in prostate cancer cells.

    Science.gov (United States)

    Wang, Lina; Liu, Chunyan; Li, Chaoyang; Xue, Jing; Zhao, Shihu; Zhan, Panpan; Lin, Yani; Zhang, Pengju; Jiang, Anli; Chen, Weiwen

    2015-11-10

    To investigate the role of miR-221/222 in cell proliferation and apoptosis in human prostate cancer cells, and examine the effects of miR-221/222 on caspase-10 expression. Prostate cancer cells were transfected with miR-221/222 mimics or inhibitors. Cell proliferation was assessed by MTT assay. The expression levels of miR-221/222 were detected with quantitative real-time PCR. Apoptosis was induced with TNF-α/CHX treatment, and evaluated by Hoechst 33342 staining, propidium iodide (PI) flow cytometric analysis, caspase-3 activity measurement, and Western blot analysis. Luciferase activity assay, quantitative real-time PCR, and Western blot were performed to evaluate the effects of miR-221/222 on caspase-10 expression. Our results showed that miR-221/222 could promote the proliferation of prostate cancer cells, including LNCaP and PC3 cells. After transfection and apoptosis induction, Hoechst 33342 staining and PI flow cytometric assay showed that apoptosis was dramatically decreased in prostate cancer cells treated with miR-221/222 mimics. Moreover, caspase-3 activity was dramatically decreased, and the cleaved forms of caspase-3 were reduced, in the miR-221/222 mimic-treated group. On the contrary, miR-221/222 knockdown sensitized the prostate cancer cells to TNF-α/CHX-induced apoptosis. In addition, a negative correlation was observed between the expressions of miR-221/222 and caspase-10 in prostate cancer cells. miR-221/222 could repress the expression of caspase-10, which was confirmed by the luciferase reporter assay. miR-221/222 promote cell proliferation and repress apoptosis, through suppressing caspase-10, in prostate cancer cells. Our results provide promising evidence for the miRNA-based therapeutic strategy of prostate cancers. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Opto-fluidics based microscopy and flow cytometry on a cell phone for blood analysis.

    Science.gov (United States)

    Zhu, Hongying; Ozcan, Aydogan

    2015-01-01

    Blood analysis is one of the most important clinical tests for medical diagnosis. Flow cytometry and optical microscopy are widely used techniques to perform blood analysis and therefore cost-effective translation of these technologies to resource limited settings is critical for various global health as well as telemedicine applications. In this chapter, we review our recent progress on the integration of imaging flow cytometry and fluorescent microscopy on a cell phone using compact, light-weight and cost-effective opto-fluidic attachments integrated onto the camera module of a smartphone. In our cell-phone based opto-fluidic imaging cytometry design, fluorescently labeled cells are delivered into the imaging area using a disposable micro-fluidic chip that is positioned above the existing camera unit of the cell phone. Battery powered light-emitting diodes (LEDs) are butt-coupled to the sides of this micro-fluidic chip without any lenses, which effectively acts as a multimode slab waveguide, where the excitation light is guided to excite the fluorescent targets within the micro-fluidic chip. Since the excitation light propagates perpendicular to the detection path, an inexpensive plastic absorption filter is able to reject most of the scattered light and create a decent dark-field background for fluorescent imaging. With this excitation geometry, the cell-phone camera can record fluorescent movies of the particles/cells as they are flowing through the microchannel. The digital frames of these fluorescent movies are then rapidly processed to quantify the count and the density of the labeled particles/cells within the solution under test. With a similar opto-fluidic design, we have recently demonstrated imaging and automated counting of stationary blood cells (e.g., labeled white blood cells or unlabeled red blood cells) loaded within a disposable cell counting chamber. We tested the performance of this cell-phone based imaging cytometry and blood analysis platform

  17. Concomitant differentiation of a population of mouse embryonic stem cells into neuron-like cells and Schwann cell-like cells in a slow-flow microfluidic device

    Science.gov (United States)

    Ramamurthy, Poornapriya; White, Joshua B.; Park, Joong Yull; Hume, Richard I.; Ebisu, Fumi; Mendez, Flor; Takayama, Shuichi; Barald, Kate F

    2016-01-01

    Background To send meaningful information to the brain, an inner ear cochlear implant (CI) must become closely coupled to as large and healthy a population of remaining Spiral Ganglion Neurons (SGN) as possible. Inner ear gangliogenesis depends on macrophage migration inhibitory factor (MIF), a directionally attractant neurotrophic cytokine made by both Schwann and supporting cells (Bank et al., 2012). MIF-induced mouse embryonic stem cell (mESC)-derived “neurons” could potentially substitute for lost or damaged SGN. mESC-derived “Schwann cells” produce MIF as do all Schwann cells (Huang et al., 2002; Roth et al., 2007, 2008) and could attract SGN to “ cell coated” implant. Results Neuron- and Schwann cell-like cells were produced from a common population of mESC in an ultra-slow flow microfluidic device. As the populations interacted; “neurons” grew over the “Schwann cell” lawn and early events in myelination were documented. Blocking MIF on the Schwann cell side greatly reduced directional neurite outgrowth. MIF-expressing “Schwann cells” were used to “coat” a CI: mouse SGN and MIF-induced “neurons” grew directionally to the CI and to a wild type but not MIF-knock out Organ of Corti explant. Conclusions Two novel stem cell-based approaches for treating the problem of sensorineural hearing loss are described. PMID:27761977

  18. Design of flow-field patterns for proton exchange membrane fuel cell application

    International Nuclear Information System (INIS)

    Rosli, M.I.; Wan Ramli Wan Daud; Kamaruzzaman Sopian; Jaa