WorldWideScience

Sample records for floor bulk density

  1. Bulk density calculations from prompt gamma ray yield

    International Nuclear Information System (INIS)

    Naqvi, A.A.; Nagadi, M.M.; Al-Amoudi, O.S.B.; Maslehuddin, M.

    2006-01-01

    Full text: The gamma ray yield from a Prompt Gamma ray Neutron Activation Analysis (PGNAA) setup is a linear function of element concentration and neutron flux in a the sample with constant bulk density. If the sample bulk density varies as well, then the element concentration and the neutron flux has a nonlinear correlation with the gamma ray yield [1]. The measurement of gamma ray yield non-linearity from samples and a standard can be used to estimate the bulk density of the samples. In this study the prompt gamma ray yield from Blast Furnace Slag, Fly Ash, Silica Fumes and Superpozz cements samples have been measured as a function of their calcium and silicon concentration using KFUPM accelerator-based PGNAA setup [2]. Due to different bulk densities of the blended cement samples, the measured gamma ray yields have nonlinear correlation with calcium and silicon concentration of the samples. The non-linearity in the yield was observed to increase with gamma rays energy and element concentration. The bulk densities of the cement samples were calculated from ratio of gamma ray yield from blended cement and that from a Portland cement standard. The calculated bulk densities have good agreement with the published data. The result of this study will be presented

  2. THE EFFECT OF DENSITY AND FLOOR TYPES ON PERFORMANCE, PHYSIOLOGICAL STATE AND IMMUNE RESPONSE OF BROILERS

    Directory of Open Access Journals (Sweden)

    D. Sunarti

    2014-10-01

    Full Text Available The purpose of this research was to study the effect of density and floor types on performance,physiological state and immune response of broilers. The research involved 368 male broilers of theNew Lohman strain aged 8 days which were raised up to 35 days at different densities and floor types.Floor types consisted of rice hull litter and bamboo slat were used as the main plot; while densities of 7,10, 13 and 16 birds/m2 applied as the sub-plot. The results showed that the final body weight gain of the35-day Lohmann broilers at densities of 7, 10 and 13 birds/m2 were 28.22, 24.43 and 19.27 kgrespectively, compared to 16 birds/m2 at 13.53 kg (P>0.05. Broilers in the bamboo slats floor hadlymph weight at 3.73 g compared to the litter floor at 2.55 g (P<0.05. Also, broilers in the bambooslats had average RHL (0.65 lower than broilers in the litter floor (0.79. It could be concluded thatbamboo slats best being used for broilers up to a density of 13 broilers/m2.

  3. Bulk density and porosity distributions in a compost pile

    NARCIS (Netherlands)

    Ginkel, van J.T.; Raats, P.A.C.; Haneghem, van I.A.

    1999-01-01

    This paper mainly deals with the description of the initial distribution of bulk density and porosity at the moment a compost pile is built or rebuilt. A relationship between bulk density and vertical position in a pile is deduced from theoretical and empirical considerations. Formulae to calculate

  4. The Effect of Density and Floor Types on Performance, Physiological State and Immune Response of Broilers

    OpenAIRE

    Sunarti, D; Haryono, H; Soedarsono, S

    2010-01-01

    The purpose of this research was to study the effect of density and floor types on performance,physiological state and immune response of broilers. The research involved 368 male broilers of theNew Lohman strain aged 8 days which were raised up to 35 days at different densities and floor types.Floor types consisted of rice hull litter and bamboo slat were used as the main plot; while densities of 7,10, 13 and 16 birds/m2 applied as the sub-plot. The results showed that the final body weight g...

  5. Is the bulk mode conversion important in high density helicon plasma?

    Energy Technology Data Exchange (ETDEWEB)

    Isayama, Shogo; Hada, Tohru [Interdisciplinary Graduate School of Engineering Sciences, Kyushu University, 6-1 Kasuga-Kohen, Kasuga, Fukuoka 816-8580 (Japan); Shinohara, Shunjiro [Institute of Engineering, Tokyo University of Agriculture and Technology, 2-24-16, Naka-cho, Koganei, Tokyo 184-8588 (Japan); Tanikawa, Takao [Research Institute of Science and Technology, Tokai University 4-1-1 Kitakaname, Hiratsuka, Kanagawa 259-1292 (Japan)

    2016-06-15

    In a high-density helicon plasma production process, a contribution of Trivelpiece-Gould (TG) wave for surface power deposition is widely accepted. The TG wave can be excited either due to an abrupt density gradient near the plasma edge (surface conversion) or due to linear mode conversion from the helicon wave in a density gradient in the bulk region (bulk mode conversion). By numerically solving the boundary value problem of linear coupling between the helicon and the TG waves in a background with density gradient, we show that the efficiency of the bulk mode conversion strongly depends on the dissipation included in the plasma, and the bulk mode conversion is important when the dissipation is small. Also, by performing FDTD simulation, we show the time evolution of energy flux associated with the helicon and the TG waves.

  6. PEDO-TRANSFER FUNCTIONS FOR ESTIMATING SOIL BULK DENSITY IN CENTRAL AMAZONIA

    Directory of Open Access Journals (Sweden)

    Henrique Seixas Barros

    2015-04-01

    Full Text Available Under field conditions in the Amazon forest, soil bulk density is difficult to measure. Rigorous methodological criteria must be applied to obtain reliable inventories of C stocks and soil nutrients, making this process expensive and sometimes unfeasible. This study aimed to generate models to estimate soil bulk density based on parameters that can be easily and reliably measured in the field and that are available in many soil-related inventories. Stepwise regression models to predict bulk density were developed using data on soil C content, clay content and pH in water from 140 permanent plots in terra firme (upland forests near Manaus, Amazonas State, Brazil. The model results were interpreted according to the coefficient of determination (R2 and Akaike information criterion (AIC and were validated with a dataset consisting of 125 plots different from those used to generate the models. The model with best performance in estimating soil bulk density under the conditions of this study included clay content and pH in water as independent variables and had R2 = 0.73 and AIC = -250.29. The performance of this model for predicting soil density was compared with that of models from the literature. The results showed that the locally calibrated equation was the most accurate for estimating soil bulk density for upland forests in the Manaus region.

  7. The effects of forward speed and depth of conservation tillage on soil bulk density

    Directory of Open Access Journals (Sweden)

    A Mahmoudi

    2015-09-01

    Full Text Available Introduction: In recent years, production techniques and equipment have been developed for conservation of tillage systems that have been adopted by many farmers. With proper management, overall yield averages for conventional and reduced tillage systems are nearly identical. Sometimes, field operations can be combined by connecting two or more implements. Combined operations reduce both fuel consumption, and time and labor requirements by eliminating at least one individual trip over the field. Light tillage, spraying, or fertilizing operations can be combined with either primary or secondary tillage or planting operations. Tillage helps seed growth and germination through providing appropriate conditions for soil to absorb sufficient temperature and humidity. Moreover, it helps easier development of root through reducing soil penetration resistance. Tillage is a time-consuming and expensive procedure. With the application of agricultural operations, we can save substantial amounts of fuel, time and energy consumption. Conservation tillage loosens the soil without turning, but by remaining the plant left overs, stems and roots. Bulk density reflects the soil’s ability to function for structural support, water and solute movement, and soil aeration. Bulk densities above thresholds indicate impaired function. Bulk density is also used to convert between weight and volume of soil. It is used to express soil physical, chemical and biological measurements on a volumetric basis for soil quality assessment and comparisons between management systems. This increases the validity of comparisons by removing the error associated with differences in soil density at the time of sampling. The aim of conservation tillage is to fix the soil structure. This investigation was carried out considering the advantages of conservation tillage and less scientific research works on imported conservation tillage devices and those which are made inside the country

  8. Soil bulk density changes caused by mechanized harvesting: A case study in central Appalachia

    Science.gov (United States)

    Jingxin Wang; Chris B. LeDoux; Pam Edwards; Mark Jones; Mark Jones

    2005-01-01

    A mechanized harvesting system consisting of a feller-buncher and a grapple skidder was examined to quantify soil bulk density changes in a central Appalachian hardwood forest site. Soil bulk density was measured using a nuclear gauge pre-harvest and post-harvest systematically across the harvest unit and on transects across skid trails. Bulk density also was measured...

  9. Laser ultrasonics for bulk-density distribution measurement on green ceramic tiles

    Science.gov (United States)

    Revel, G. M.; Cavuto, A.; Pandarese, G.

    2016-10-01

    In this paper a Laser Ultrasonics (LUT) system is developed and applied to measure bulk density distribution of green ceramic tiles, which are porous materials with low heat conductivity. Bulk density of green ceramic bodies is a fundamental parameter to be kept under control in the industrial production of ceramic tiles. The LUT system proposed is based on a Nd:YAG pulsed laser for excitation and an air-coupled electro-capacitive transducer for detection. The paper reports experimental apparent bulk-density measurements on white ceramic bodies after a calibration procedures. The performances observed are better than those previously achieved by authors using air-coupled ultrasonic probes for both emission and detection, allowing to reduce average uncertainty down to about ±6 kg/m3 (±0.3%), thanks to the increase in excitation efficiency and lateral resolution, while maintaining potential flexibility for on-line application. The laser ultrasonic procedure proposed is available for both on-line and off-line application. In this last case it is possible to obtain bulk density maps with high spatial resolution by a 2D scan without interrupting the production process.

  10. Grain bulk density measurement based on wireless network

    Directory of Open Access Journals (Sweden)

    Wu Fangming

    2017-01-01

    Full Text Available To know the accurate quantity of stored grain, grain density sensors must be used to measure the grain’s bulk density. However, multi-sensors should be inserted into the storage facility, to quickly collect data during the inventory checking of stored grain. In this study, the ZigBee and Wi-Fi coexistence network’s ability to transmit data collected by density sensors was investigated. A system consisting of six sensor nodes, six router nodes, one gateway and one Android Pad was assembled to measure the grain’s bulk density and calculate its quantity. The CC2530 chip with ZigBee technology was considered as the core of the information processing, and wireless nodes detection in sensor, and router nodes. ZigBee worked in difference signal channel with Wi-Fi to avoid interferences and connected with Wi-Fi module by UART serial communications interfaces in gateway. The Android Pad received the measured data through the gateway and processed this data to calculate quantity. The system enabled multi-point and real-time parameter detection inside the grain storage. Results show that the system has characteristics of good expansibility, networking flexibility and convenience.

  11. Technique of Critical Current Density Measurement of Bulk Superconductor with Linear Extrapolation Method

    International Nuclear Information System (INIS)

    Adi, Wisnu Ari; Sukirman, Engkir; Winatapura, Didin S.

    2000-01-01

    Technique of critical current density measurement (Jc) of HTc bulk ceramic superconductor has been performed by using linear extrapolation with four-point probes method. The measurement of critical current density HTc bulk ceramic superconductor usually causes damage in contact resistance. In order to decrease this damage factor, we introduce extrapolation method. The extrapolating data show that the critical current density Jc for YBCO (123) and BSCCO (2212) at 77 K are 10,85(6) Amp.cm - 2 and 14,46(6) Amp.cm - 2, respectively. This technique is easier, simpler, and the use of the current flow is low, so it will not damage the contact resistance of the sample. We expect that the method can give a better solution for bulk superconductor application. Key words. : superconductor, critical temperature, and critical current density

  12. Chemistry of burning the forest floor during the FROSTFIRE experimental burn, interior Alaska, 1999.

    Science.gov (United States)

    J.W. Harden; J.C. Neff; D.V. Sandberg; M.R. Turetsky; R. Ottmar; G. Gleixner; T.L. Fries; K.L. Manies

    2004-01-01

    Wildfires represent one of the most common disturbances in boreal regions, and have the potential to reduce C, N, and Hg stocks in soils while contributing to atmospheric emissions. Organic soil layers of the forest floor were sampled before and after the FROSTFIRE experimental burn in interior Alaska, and were analyzed for bulk density, major and trace elements, and...

  13. Bulk density estimation using a 3-dimensional image acquisition and analysis system

    Directory of Open Access Journals (Sweden)

    Heyduk Adam

    2016-01-01

    Full Text Available The paper presents a concept of dynamic bulk density estimation of a particulate matter stream using a 3-d image analysis system and a conveyor belt scale. A method of image acquisition should be adjusted to the type of scale. The paper presents some laboratory results of static bulk density measurements using the MS Kinect time-of-flight camera and OpenCV/Matlab software. Measurements were made for several different size classes.

  14. Effects of gypsum and bulk density on neutron probe calibration curves

    International Nuclear Information System (INIS)

    Arslan, Awadis; Razzouk, A.K.

    1993-10-01

    The effects of gypsum and bulk density on the neutron probe calibration curve were studied in the laboratory and in the field. The effect of bulk density was negligible for the soil studied in the laboratory, while it was significant for the field calibration. An increase in the slope of moisture content on a volume basis vs. count ratio with increasing gypsum content at the soil was observed in the laboratory calibration. A simple method for correction of the calibration curve for gypsum content was adopted to obtain a specific curve for each layer. The adapted method requires the gypsum fraction to be estimated for each layer and then incorporated in the calibration curve to improve the coefficient of determination. A field calibration showed an improvement of the determination coefficient by introducing bulk density and gypsum fraction, in addition to count ratio using moisture content on a volume basis as a dependent variable in multi linear regression analysis. The same procedure was successful with variable gravel fractions. (author). 18 refs., 3 figs., 2 tabs

  15. Surface flux density distribution characteristics of bulk high-Tc superconductor in external magnetic field

    International Nuclear Information System (INIS)

    Torii, S.; Yuasa, K.

    2004-01-01

    Various magnetic levitation systems using oxide superconductors are developed as strong pinning forces are obtained in melt-processed bulk. However, the trapped flux of superconductor is moved by flux creep and fluctuating magnetic field. Therefore, to examine the internal condition of superconductor, the authors measure the dynamic surface flux density distribution of YBCO bulk. Flux density measurement system has a structure with the air-core coil and the Hall sensors. Ten Hall sensors are arranged in series. The YBCO bulk, which has 25 mm diameter and 13 mm thickness, is field cooled by liquid nitrogen. After that, magnetic field is changed by the air-core coil. This paper describes about the measured results of flux density distribution of YBCO bulk in the various frequencies of air-core coils currents

  16. Surface flux density distribution characteristics of bulk high- Tc superconductor in external magnetic field

    Science.gov (United States)

    Torii, S.; Yuasa, K.

    2004-10-01

    Various magnetic levitation systems using oxide superconductors are developed as strong pinning forces are obtained in melt-processed bulk. However, the trapped flux of superconductor is moved by flux creep and fluctuating magnetic field. Therefore, to examine the internal condition of superconductor, the authors measure the dynamic surface flux density distribution of YBCO bulk. Flux density measurement system has a structure with the air-core coil and the Hall sensors. Ten Hall sensors are arranged in series. The YBCO bulk, which has 25 mm diameter and 13 mm thickness, is field cooled by liquid nitrogen. After that, magnetic field is changed by the air-core coil. This paper describes about the measured results of flux density distribution of YBCO bulk in the various frequencies of air-core coils currents.

  17. Surface flux density distribution characteristics of bulk high-T c superconductor in external magnetic field

    International Nuclear Information System (INIS)

    Nishikawa, H.; Torii, S.; Yuasa, K.

    2005-01-01

    This paper describes the measured results of the two-dimensional flux density distribution of a YBCO bulk under applied AC magnetic fields with various frequency. Melt-processed oxide superconductors have been developed in order to obtain strong pinning forces. Various electric mechanical systems or magnetic levitation systems use those superconductors. The major problem is that cracks occur because the bulk superconductors are brittle. The bulk may break in magnetizing process after cracks make superconducting state instable. The trapped flux density and the permanent current characteristics of bulk superconductors have been analyzed, so as to examine the magnetizing processes or superconducting states of the bulk. In those studies, the two-dimensional surface flux density distributions of the bulk in static fields are discussed. On the other hand, the distributions in dynamic fields are little discussed. We attempted to examine the states of the bulk in the dynamic fields, and made a unique experimental device which has movable sensors synchronized with AC applied fields. As a result, the two-dimensional distributions in the dynamic fields are acquired by recombining the one-dimensional distributions. The dynamic states of the flux of the bulk and the influences of directions of cracks are observed from the distributions. In addition, a new method for measuring two-dimensional flux density distribution under dynamic magnetic fields is suggested

  18. Investigation of bulk electron densities for dose calculations on cone-beam CT images

    International Nuclear Information System (INIS)

    Lambert, J.; Parker, J.; Gupta, S.; Hatton, J.; Tang, C.; Capp, A.; Denham, J.W.; Wright, P.

    2010-01-01

    Full text: If cone-beam CT images are to be used for dose calculations, then the images must be able to provide accurate electron density information. Twelve patients underwent twice weekly cone-beam CT scans in addition to the planning CT scan. A standardised 5-field treatment plan was applied to 169 of the CBCT images. Doses were calculated using the original electron density values in the CBCT and with bulk electron densities applied. Bone was assigned a density of 288 HU, and all other tissue was assigned to be water equivalent (0 HU). The doses were compared to the dose calculated on the original planning CT image. Using the original HU values in the cone-beam images, the average dose del i vered by the plans from all 12 patients was I. I % lower than the intended 200 cOy delivered on the original CT plans (standard devia tion 0.7%, maximum difference -2.93%). When bulk electron densities were applied to the cone-beam images, the average dose was 0.3% lower than the original CT plans (standard deviation 0.8%, maximum difference -2.22%). Compared to using the original HU values, applying bulk electron densities to the CBCT images improved the dose calculations by almost I %. Some variation due to natural changes in anatomy should be expected. The application of bulk elec tron densities to cone beam CT images has the potential to improve the accuracy of dose calculations due to inaccurate H U values. Acknowledgements This work was partially funded by Cancer Council NSW Grant Number RG 07-06.

  19. The determination of bulk (apparent) density of plant fibres by density method

    International Nuclear Information System (INIS)

    Sharifah Hanisah Syed Abd Aziz; Raja Jamal Raja hedar; Zahid Abdullah

    2004-01-01

    The absolute density of plant fibres excludes all pores and lumen and therefore is a measure of the solid matter of the fibres. On the other hand the bulk density, which is being discussed here, includes all the solid matter and the pores of the fibres. In this work, the apparent density of the fibre was measured by using the Archimedes principle, which involves the immersion of a known weight of fibre into a solvent of lower density than the fibre. Toluene with a density of about 860 kg/m3 was chosen as a solvent. A tuft of fibre was weighed and recorded as W fa . The fibre was then immersed in toluene, which wetted the fibre, and made to rest on the weighing pan submerged in the solvent and the weight of the immersed fibre was recorded as W fs . The apparent density was then calculated using the equation. All the measurements were taken at room temperature. The fibre samples were not oven dried prior to measurement. (Author)

  20. Food Simulating Organic Solvents for Evaluating Crosslink Density of Bulk Fill Composite Resin

    Directory of Open Access Journals (Sweden)

    Neveen M. Ayad

    2017-01-01

    Full Text Available Objectives. To evaluate crosslink densities of two bulk fill composite resins and determine if the used Food Simulating Organic Solvent (FSOS affected them. Methods. Forty specimens were prepared from SureFill and SonicFill bulk fill composite resins, 20 each. All specimens were stored dry for 24 h. Each group was divided into 2 subgroups: stored in ethanol (E 75% or in methyl ethyl ketone (MEK 100% for 24 h. Crosslink density was evaluated by calculating the difference between the Vickers hardness numbers of the specimens stored dry and after their storage in FSOS. The data were statistically analyzed using t-test. Results. The means of crosslink density in E and MEK were 6.99% and 9.44% for SureFill and 10.54% and 11.92% for SonicFill, respectively. t-test displayed significant differences between crosslink densities of SureFill and SonicFill: (P<0.0001 in E and (P=0.02 in MEK and between crosslink densities of SureFill in E and MEK (P=0.02. Conclusions. Crosslink density of bulk fill composite resin can be evaluated using E or MEK. SureFill has higher crosslink density than SonicFill in both E and MEK.

  1. Estimating Soil Bulk Density and Total Nitrogen from Catchment ...

    African Journals Online (AJOL)

    Even though data on soil bulk density (BD) and total nitrogen (TN) are essential for planning modern farming techniques, their data availability is limited for many applications in the developing word. This study is designed to estimate BD and TN from soil properties, land-use systems, soil types and landforms in the ...

  2. Experimental Investigation of Properties of Foam Concrete for Industrial Floors in Testing Field

    Science.gov (United States)

    Vlcek, Jozef; Drusa, Marian; Scherfel, Walter; Sedlar, Bronislav

    2017-12-01

    Foam concrete (FC), as a mixture of cement, water, additives and technical foam, is well known for more than 30 years. It is building material with good mechanical properties, low thermal conductivity, simple and even high technological treatment. Foam concrete contains closed void pores, what allows achieving low bulk density and spare of raw materials. Thanks to its properties, it is usable as a replacement of conventional subbase layers of the industrial floors, the transport areas or as a part of the foundation structures of the buildings. Paper presents the preparation of the testing field (physical model) which was created for experimental investigation of the foam concrete subbase layer of the industrial floor in a real scale.

  3. Sample sizes to control error estimates in determining soil bulk density in California forest soils

    Science.gov (United States)

    Youzhi Han; Jianwei Zhang; Kim G. Mattson; Weidong Zhang; Thomas A. Weber

    2016-01-01

    Characterizing forest soil properties with high variability is challenging, sometimes requiring large numbers of soil samples. Soil bulk density is a standard variable needed along with element concentrations to calculate nutrient pools. This study aimed to determine the optimal sample size, the number of observation (n), for predicting the soil bulk density with a...

  4. THE RELATIONSHIP BETWEEN BULK-DENSITY AND COMPACTIBILITY OF LACTOSE GRANULATIONS

    NARCIS (Netherlands)

    ZUURMAN, K; RIEPMA, KA; BOLHUIS, GK; VROMANS, H; LERK, CF

    1994-01-01

    The relationship between the bulk density and the compactibility of lactose granulations was studied. The granulations were prepared from different alpha-lactose monohydrate and roller dried beta-lactose powders by wet granulation, using different techniques with only water as a binder, or by

  5. Estimating forest canopy bulk density using six indirect methods

    Science.gov (United States)

    Robert E. Keane; Elizabeth D. Reinhardt; Joe Scott; Kathy Gray; James Reardon

    2005-01-01

    Canopy bulk density (CBD) is an important crown characteristic needed to predict crown fire spread, yet it is difficult to measure in the field. Presented here is a comprehensive research effort to evaluate six indirect sampling techniques for estimating CBD. As reference data, detailed crown fuel biomass measurements were taken on each tree within fixed-area plots...

  6. Surface flux density distribution characteristics of bulk high-T{sub c} superconductor in external magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Torii, S.; Yuasa, K

    2004-10-01

    Various magnetic levitation systems using oxide superconductors are developed as strong pinning forces are obtained in melt-processed bulk. However, the trapped flux of superconductor is moved by flux creep and fluctuating magnetic field. Therefore, to examine the internal condition of superconductor, the authors measure the dynamic surface flux density distribution of YBCO bulk. Flux density measurement system has a structure with the air-core coil and the Hall sensors. Ten Hall sensors are arranged in series. The YBCO bulk, which has 25 mm diameter and 13 mm thickness, is field cooled by liquid nitrogen. After that, magnetic field is changed by the air-core coil. This paper describes about the measured results of flux density distribution of YBCO bulk in the various frequencies of air-core coils currents.

  7. Effect of density increase on self-absorption property of bulk samples

    International Nuclear Information System (INIS)

    Dao Anh Minh; Tran Duc Thiep

    1990-01-01

    Asymptotic behaviour due to self-absorption of photon attenuation function in terms of material density for bulk samples has been considered. Some practical applications have also been presented. (author). 9 refs., 4 figs., 2 tabs

  8. A two-population sporadic meteoroid bulk density distribution and its implications for environment models

    Science.gov (United States)

    Moorhead, Althea V.; Blaauw, Rhiannon C.; Moser, Danielle E.; Campbell-Brown, Margaret D.; Brown, Peter G.; Cooke, William J.

    2017-12-01

    The bulk density of a meteoroid affects its dynamics in space, its ablation in the atmosphere, and the damage it does to spacecraft and lunar or planetary surfaces. Meteoroid bulk densities are also notoriously difficult to measure, and we are typically forced to assume a density or attempt to measure it via a proxy. In this paper, we construct a density distribution for sporadic meteoroids based on existing density measurements. We considered two possible proxies for density: the KB parameter introduced by Ceplecha and Tisserand parameter, TJ. Although KB is frequently cited as a proxy for meteoroid material properties, we find that it is poorly correlated with ablation-model-derived densities. We therefore follow the example of Kikwaya et al. in associating density with the Tisserand parameter. We fit two density distributions to meteoroids originating from Halley-type comets (TJ 2); the resulting two-population density distribution is the most detailed sporadic meteoroid density distribution justified by the available data. Finally, we discuss the implications for meteoroid environment models and spacecraft risk assessments. We find that correcting for density increases the fraction of meteoroid-induced spacecraft damage produced by the helion/antihelion source.

  9. Bulk contribution to magnetotransport properties of low-defect-density Bi2Te3 topological insulator thin films

    Science.gov (United States)

    Ngabonziza, P.; Wang, Y.; Brinkman, A.

    2018-04-01

    An important challenge in the field of topological materials is to carefully disentangle the electronic transport contribution of the topological surface states from that of the bulk. For Bi2Te3 topological insulator samples, bulk single crystals and thin films exposed to air during fabrication processes are known to be bulk conducting, with the chemical potential in the bulk conduction band. For Bi2Te3 thin films grown by molecular beam epitaxy, we combine structural characterization (transmission electron microscopy), chemical surface analysis as function of time (x-ray photoelectron spectroscopy) and magnetotransport analysis to understand the low defect density and record high bulk electron mobility once charge is doped into the bulk by surface degradation. Carrier densities and electronic mobilities extracted from the Hall effect and the quantum oscillations are consistent and reveal a large bulk carrier mobility. Because of the cylindrical shape of the bulk Fermi surface, the angle dependence of the bulk magnetoresistance oscillations is two dimensional in nature.

  10. Changes in soil bulk density resulting from construction and conventional cable skidding using preplanned skid trails

    Science.gov (United States)

    Jingxin Wang; Chris B. LeDoux; Pam Edwards

    2007-01-01

    A harvesting system consisting of chainsaw felling and cable skidder extraction was studied to determine soil bulk density changes in a central Appalachian hardwood forest site. Soil bulk density was measured using a nuclear gauge preharvest and postharvest systematically across the harvest site, on transects across skid trails, and for a subset of skid trail transects...

  11. Organic carbon organic matter and bulk density relationships in arid ...

    African Journals Online (AJOL)

    Soil organic matter (SOM) and soil organic carbon (SOC) constitute usually a small portion of soil, but they are one of the most important components of ecosystems. Bulk density (dB or BD) value is necessary to convert organic carbon (OC) content per unit area. Relationships between SOM, SOC and BD were established ...

  12. Effect of collimator size and absorber thickness on soil bulk density evaluation by gamma-ray attenuation

    International Nuclear Information System (INIS)

    Costa, J.C.; Borges, J.A.R.; Pires, L.F.

    2014-01-01

    Representative measurements of the soil bulk density (ρ s ) can be affected depending on the geometry selected for gamma-ray attenuation (GRA) measurements. In this study, the effect of collimator size (2–4 mm diameters) and absorber thickness (2–15 cm) on ρ s measurements of sandy and clayey soils was investigated. In summary, the results obtained for the 137 Cs show that ρ s remained fairly constant for values of thickness larger than 7 cm (both soils). The very same result was observed for collimator sizes 2–4 mm. Regarding the 241 Am source, ρ s values presented variations with the collimator size (both soils) for the different thicknesses. The best values of ρ s were obtained for samples smaller than 5 cm and also for the small collimator diameters. - Highlights: ► Representative measurements of the soil bulk density by gamma-ray attenuation. ► For 137 Cs the best bulk density values were obtained for samples larger than 7 cm. ► For 241 Am the best bulk density values were obtained for samples smaller than 5 cm

  13. Near surface bulk density estimates of NEAs from radar observations and permittivity measurements of powdered geologic material

    Science.gov (United States)

    Hickson, Dylan; Boivin, Alexandre; Daly, Michael G.; Ghent, Rebecca; Nolan, Michael C.; Tait, Kimberly; Cunje, Alister; Tsai, Chun An

    2018-05-01

    The variations in near-surface properties and regolith structure of asteroids are currently not well constrained by remote sensing techniques. Radar is a useful tool for such determinations of Near-Earth Asteroids (NEAs) as the power of the reflected signal from the surface is dependent on the bulk density, ρbd, and dielectric permittivity. In this study, high precision complex permittivity measurements of powdered aluminum oxide and dunite samples are used to characterize the change in the real part of the permittivity with the bulk density of the sample. In this work, we use silica aerogel for the first time to increase the void space in the samples (and decrease the bulk density) without significantly altering the electrical properties. We fit various mixing equations to the experimental results. The Looyenga-Landau-Lifshitz mixing formula has the best fit and the Lichtenecker mixing formula, which is typically used to approximate planetary regolith, does not model the results well. We find that the Looyenga-Landau-Lifshitz formula adequately matches Lunar regolith permittivity measurements, and we incorporate it into an existing model for obtaining asteroid regolith bulk density from radar returns which is then used to estimate the bulk density in the near surface of NEA's (101955) Bennu and (25143) Itokawa. Constraints on the material properties appropriate for either asteroid give average estimates of ρbd = 1.27 ± 0.33g/cm3 for Bennu and ρbd = 1.68 ± 0.53g/cm3 for Itokawa. We conclude that our data suggest that the Looyenga-Landau-Lifshitz mixing model, in tandem with an appropriate radar scattering model, is the best method for estimating bulk densities of regoliths from radar observations of airless bodies.

  14. Optimising mechanical strength and bulk density of dry ceramic bodies through mixture design

    Directory of Open Access Journals (Sweden)

    Correia, S. L.

    2005-02-01

    Full Text Available In industrial practice, it is desirable to be able to predict, in an expeditious way, what the effects of a change in raw materials or the proportions thereof might be in the various processing steps towards the final product. When the property of interest is basically determined by the combination (or mixture of raw materials, an optimisation methodology specific to the design of mixture experiments can be successfully used. In the present study, dry bending strength and bulk density were selected as the properties to model, given the simplicity of their experimental determination and because they are frequently used as quality control parameter in the development and manufacture stages of floor and wall ceramic tiles. Ten formulations of three raw materials (a clay mixture, potash feldspar and quartz sand were processed in the laboratory under fixed conditions, similar to those used in the ceramics industry, and characterised. The use of this methodology enabled the calculation of valid regression models (equations relating dry bending strength and bulk density with the contents, in the starting mixture, of the particular raw materials used.

    En el trabajo industrial es deseable poder predecir de manera efectiva, los efectos que los cambios en las materias primas o en sus proporciones pueden ejercer sobre las variables del proceso y como estos afectan al producto final. Cuando la propiedad de interés depende preferentemente de la mezcla de las materias primas, una metodología específica de optimización para el diseño de los experimentos de mezclas puede ser empleada con éxito. En este trabajo, la resistencia mecánica en seco y la densidad se emplearon como los parámetros de control en el desarrollo y producción de azulejos cerámicos para pavimento y revestimiento. Diez formulaciones a partir de tres materias primas ( una mezcla de arcilla, feldespato potásico y arena de cuarzo fueron procesadas en el laboratorio bajo

  15. POWER SPECTRAL DENSITY OF FLUCTUATIONS OF BULK AND THERMAL SPEEDS IN THE SOLAR WIND

    International Nuclear Information System (INIS)

    Šafránková, J.; Němeček, Z.; Němec, F.; Přech, L.; Chen, C. H. K.; Zastenker, G. N.

    2016-01-01

    This paper analyzes solar wind power spectra of bulk and thermal speed fluctuations that are computed with a time resolution of 32 ms in the frequency range of 0.001–2 Hz. The analysis uses measurements of the Bright Monitor of the Solar Wind on board the Spektr-R spacecraft that are limited to 570 km s 1 bulk speed. The statistics, based on more than 42,000 individual spectra, show that: (1) the spectra of bulk and thermal speeds can be fitted by two power-law segments; (2) despite their large variations, the parameters characterizing frequency spectrum fits computed on each particular time interval are very similar for both quantities; (3) the median slopes of the bulk and thermal speeds of the segment attributed to the MHD scale are 1.43 and 1.38, respectively, whereas they are 3.08 and 2.43 in the kinetic range; (4) the kinetic range slopes of bulk and thermal speed spectra become equal when either the ion density or magnetic field strength are high; (5) the break between MHD and kinetic scales seems to be controlled by the ion β parameter; (6) the best scaling parameter for bulk and thermal speed variations is a sum of the inertial length and proton thermal gyroradius; and (7) the above conclusions can be applied to the density variations if the background magnetic field is very low.

  16. POWER SPECTRAL DENSITY OF FLUCTUATIONS OF BULK AND THERMAL SPEEDS IN THE SOLAR WIND

    Energy Technology Data Exchange (ETDEWEB)

    Šafránková, J.; Němeček, Z.; Němec, F.; Přech, L. [Charles University, Faculty of Mathematics and Physics, V Holešovičkách 2, 180 00 Prague 8 (Czech Republic); Chen, C. H. K. [Department of Physics, Imperial College London, London SW7 2AZ (United Kingdom); Zastenker, G. N., E-mail: jana.safrankova@mff.cuni.cz [Space Research Institute of Russian Academy of Sciences, Moscow, Russia, Profsoyuznaya ul. 84/32, Moscow 117997 (Russian Federation)

    2016-07-10

    This paper analyzes solar wind power spectra of bulk and thermal speed fluctuations that are computed with a time resolution of 32 ms in the frequency range of 0.001–2 Hz. The analysis uses measurements of the Bright Monitor of the Solar Wind on board the Spektr-R spacecraft that are limited to 570 km s{sup 1} bulk speed. The statistics, based on more than 42,000 individual spectra, show that: (1) the spectra of bulk and thermal speeds can be fitted by two power-law segments; (2) despite their large variations, the parameters characterizing frequency spectrum fits computed on each particular time interval are very similar for both quantities; (3) the median slopes of the bulk and thermal speeds of the segment attributed to the MHD scale are 1.43 and 1.38, respectively, whereas they are 3.08 and 2.43 in the kinetic range; (4) the kinetic range slopes of bulk and thermal speed spectra become equal when either the ion density or magnetic field strength are high; (5) the break between MHD and kinetic scales seems to be controlled by the ion β parameter; (6) the best scaling parameter for bulk and thermal speed variations is a sum of the inertial length and proton thermal gyroradius; and (7) the above conclusions can be applied to the density variations if the background magnetic field is very low.

  17. Mathematical modelling in simulate bulk density as a function of shrinkage and collapse mechanics during drying of food products

    NARCIS (Netherlands)

    Almeida-Rivera, C.; Khalloufi, S.; Janssen, J.; Bongers, P.M.M.; Pierucci, S.; Buzzi Ferraris, G.

    2010-01-01

    During drying, food products undergo several physical and structural changes. These changes have a direct impact on properties such as bulk density which is involved in heat and mass transfer processes. Therefore, the prediction of the bulk density as function of water content will be an interesting

  18. Development of Low Density CaMg-A1-Based Bulk Metallic Glasses (Preprint)

    National Research Council Canada - National Science Library

    Senkov, O. N; Scott, J. M; Miracle, D. B

    2006-01-01

    Low density Ca-Mg-Al-based bulk metallic glasses containing additionally Cu and Zn, were produced by a copper mold casting method as wedge-shaped samples with thicknesses varying from 0.5 mm to 10 rom...

  19. Near-surface bulk densities of asteroids derived from dual-polarization radar observations

    Science.gov (United States)

    Virkki, A.; Taylor, P. A.; Zambrano-Marin, L. F.; Howell, E. S.; Nolan, M. C.; Lejoly, C.; Rivera-Valentin, E. G.; Aponte, B. A.

    2017-09-01

    We present a new method to constrain the near-surface bulk density and surface roughness of regolith on asteroid surfaces using planetary radar measurements. The number of radar observations has increased rapidly during the last five years, allowing us to compare and contrast the radar scattering properties of different small-body populations and compositional types. This provides us with new opportunities to investigate their near-surface physical properties such as the chemical composition, bulk density, porosity, or the structural roughness in the scale of centimeters to meters. Because the radar signal can penetrate into a planetary surface up to a few decimeters, radar can reveal information that is hidden from other ground-based methods, such as optical and infrared measurements. The near-surface structure of asteroids and comets in centimeter-to-meter scale is essential information for robotic and human space missions, impact threat mitigation, and understanding the history of these bodies as well as the formation of the whole Solar System.

  20. Neutron Gauge Calibration Curve as Affected by Chloride Concentration and Bulk Density of Loam Soil

    International Nuclear Information System (INIS)

    AL-Hasani, A.A.; Fahad, A.A.; Shihab, R.M.

    2010-01-01

    chloride concentration and bulk density are considered among important factors affecting calibration curve of neutron gauge in the soil.The aim of this study was to investigate the effect of chloride concentration and bulk density of a loam soil on neutron gauge calibration curve.Sufficient amount of loam soil was air dried screened through a 2 mm sieve,and divided into three equal portions.Sodium chloride of 2.5 and 6.6g kg'-1 soil was added to the first and second portions,respectively.The third portion was left as a control.The soil then moistened and mixed well to make volumetric water content within the range of 0.01 to 0.24 cm 3 cm - 3. The moist soil was packed into an iron drum 0.80 m diameter and 1.00 m height to obtain bulk densities of 1.10 and 1.30 to 1.60 Mg m - 3 for uncompacted soil,respectively.Access tube 0.05 m inner diameter was installed in the center of the drum.Three readings from CPN 503 neutron gauge were taken at each 0.15,0.30, 0.45,and 0.75 m depth.Results indicated that the count (counts/standard count) for an aqueous solution decreased with the increase in chloride concentration.Similarly, the slope of the linear calibration curves of the investigated soil decreased with the increase in chloride concentration.Shifting of the curves was 9 to 10%for the uncompacted soil, whereas it was 12 to 14 % for the compacted of low and high concentration of chloride, respectively . Results of changing bulk density always reduced the slope value as compared with the uncorrected count ratio.

  1. How accurate are pedotransfer functions for bulk density for Brazilian soils?

    Directory of Open Access Journals (Sweden)

    Raquel Stucchi Boschi

    Full Text Available ABSTRACT: The aim of this study was to evaluate the performance of pedotransfer functions (PTFs available in the literature to estimate soil bulk density (ρb in different regions of Brazil, using different metrics. The predictive capacity of 25 PTFs was evaluated using the mean absolute error (MAE, mean error (ME, root mean squared error (RMSE, coefficient of determination (R2 and the regression error characteristic (REC curve. The models performed differently when comparing observed and estimated ρb values. In general, the PTFs showed a performance close to the mean value of the bulk density data, considered as the simplest possible estimation of an attribute and used as a parameter to compare the performance of existing models (null model. The models developed by Benites et al. (2007 (BEN-C and by Manrique and Jones (1991 (M&J-B presented the best results. The separation of data into two layers according to depth (0-10 cm and 10-30 cm demonstrated better performance in the 10-30 cm layer. The REC curve allowed for a simple and visual evaluation of the PTFs.

  2. Determination of bulk and interface density of states in metal oxide semiconductor thin-film transistors by using capacitance-voltage characteristics

    Science.gov (United States)

    Wei, Xixiong; Deng, Wanling; Fang, Jielin; Ma, Xiaoyu; Huang, Junkai

    2017-10-01

    A physical-based straightforward extraction technique for interface and bulk density of states in metal oxide semiconductor thin film transistors (TFTs) is proposed by using the capacitance-voltage (C-V) characteristics. The interface trap density distribution with energy has been extracted from the analysis of capacitance-voltage characteristics. Using the obtained interface state distribution, the bulk trap density has been determined. With this method, for the interface trap density, it is found that deep state density nearing the mid-gap is approximately constant and tail states density increases exponentially with energy; for the bulk trap density, it is a superposition of exponential deep states and exponential tail states. The validity of the extraction is verified by comparisons with the measured current-voltage (I-V) characteristics and the simulation results by the technology computer-aided design (TCAD) model. This extraction method uses non-numerical iteration which is simple, fast and accurate. Therefore, it is very useful for TFT device characterization.

  3. 3D-Laser-Scanning Technique Applied to Bulk Density Measurements of Apollo Lunar Samples

    Science.gov (United States)

    Macke, R. J.; Kent, J. J.; Kiefer, W. S.; Britt, D. T.

    2015-01-01

    In order to better interpret gravimetric data from orbiters such as GRAIL and LRO to understand the subsurface composition and structure of the lunar crust, it is import to have a reliable database of the density and porosity of lunar materials. To this end, we have been surveying these physical properties in both lunar meteorites and Apollo lunar samples. To measure porosity, both grain density and bulk density are required. For bulk density, our group has historically utilized sub-mm bead immersion techniques extensively, though several factors have made this technique problematic for our work with Apollo samples. Samples allocated for measurement are often smaller than optimal for the technique, leading to large error bars. Also, for some samples we were required to use pure alumina beads instead of our usual glass beads. The alumina beads were subject to undesirable static effects, producing unreliable results. Other investigators have tested the use of 3d laser scanners on meteorites for measuring bulk volumes. Early work, though promising, was plagued with difficulties including poor response on dark or reflective surfaces, difficulty reproducing sharp edges, and large processing time for producing shape models. Due to progress in technology, however, laser scanners have improved considerably in recent years. We tested this technique on 27 lunar samples in the Apollo collection using a scanner at NASA Johnson Space Center. We found it to be reliable and more precise than beads, with the added benefit that it involves no direct contact with the sample, enabling the study of particularly friable samples for which bead immersion is not possible

  4. Calibration, field-testing, and error analysis of a gamma-ray probe for in situ measurement of dry bulk density

    International Nuclear Information System (INIS)

    Bertuzzi, P.; Bruckler, L.; Gabilly, Y.; Gaudu, J.C.

    1987-01-01

    This paper describes a new gamma-ray probe for measuring dry bulk density in the field. This equipment can be used with three different tube spacings (15, 20 and 30 cm). Calibration procedures and local error analyses are proposed for two cases: (1) for the case where the access tubes are parallel, calibration equations are given for three tube spacings. The linear correlation coefficient obtained in the laboratory is satisfactory (0.999), and a local error analysis shows that the standard deviation in the measured dry bulk density is small (+/- 0.02 g/cm 3 ); (2) when the access tubes are not parallel, a new calibration procedure is presented that accounts for and corrects measurement bias due to the deviating probe spacing. The standard deviation associated with the measured dry bulk density is greater (+/- 0.05 g/cm 3 ), but the measurements themselves are regarded as unbiased. After comparisons of core samplings and gamma-ray probe measurements, a field validation of the gamma-ray measurements is presented. Field validation was carried out on a variety of soils (clay, clay loam, loam, and silty clay loam), using gravimetric water contents that varied from 0.11 0.27 and dry bulk densities ranging from 1.30-1.80 g°cm -3 . Finally, an example of dry bulk density field variability is shown, and the spatial variability is analyzed in regard to the measurement errors

  5. High current density in bulk YBa2Cu3O/sub x/ superconductor

    International Nuclear Information System (INIS)

    Salama, K.; Selvamanickam, V.; Gao, L.; Sun, K.

    1989-01-01

    A liquid phase processing method for the fabrication of bulk YBa 2 Cu 3 O/sub x/ superconductors with large current carrying capacity has been developed. Slow cooling through the peritectic transformation (1030--980 degree C) has been shown to control the microstructure of these superconductors. A cooling rate of 1 degree C/h in this temperature range has yielded a microstructure with long plate type, thick grains oriented over a wide area. Current density up to 18 500 A/cm 2 has been obtained by continuous direct current measurements and in excess of 62 000 A/cm 2 with pulse current of 10 ms duration and 75 000 A/cm 2 using 1 ms pulse. The strong magnetic field dependence observed in sintered bulk 1-2-3 superconductors is also minimized to a large extent where a current density in excess of 37 000 A/cm 2 is obtained in a field of 6000 G

  6. Method of altering the effective bulk density of solid material and the resulting product: hollow polymeric particles

    International Nuclear Information System (INIS)

    Kool, L.B.; Nolen, R.L.; Solomon, D.E.

    1981-01-01

    Hollow spherical particles are made by spraying a mixture of powdered solid material with a solution of a film-forming polymer in a solvent therefor into a heated chamber where the solvent evaporates. The powder is thereby captured in the wall of the hollow polymer particles formed. Such particles are used to form a suspension in a fluid material. The hollow particles are of such size and wall thickness, in relation to the bulk density of the powdered solid material, that the bulk density of each hollow spherical particle is commensurate with the density of the fluid material. The particles thereby remain in suspension over a substantial period of time with little or no agitation of the fluid. (author)

  7. Effects of Nb and Si on densities of valence electrons in bulk and defects of Fe3Al alloys

    Institute of Scientific and Technical Information of China (English)

    邓文; 钟夏平; 黄宇阳; 熊良钺; 王淑荷; 郭建亭; 龙期威

    1999-01-01

    Positron lifetime measurements have been performed in binary Fe3Al and Fe3Al doping with Nb or Si alloys. The densities of valence electrons of the bulk and microdefects in all tested samples have been calculated by using the positron lifetime parameters. Density of valence electron is low in the bulk of Fe3Al alloy. It indicates that, the 3d electrons in a Fe atom have strong-localized properties and tend to form covalent bonds with Al atoms, and the bonding nature in Fe3Al is a mixture of metallic and covalent bonds. The density of valence electron is very low in the defects of Fe3Al grain boundary, which makes the bonding cohesion in grain boundary quite weak. The addition of Si to Fe3Al gives rise to the decrease of the densities of valence electrons in the bulk and the grain boundary thus the metallic bonding cohesion. This makes the alloy more brittle. The addition of Nb to Fe3Al results in the decrease of the ordering energy of the alloy and increases the density of valence electron and th

  8. Using machine learning to predict soil bulk density on the basis of visual parameters

    NARCIS (Netherlands)

    Bondi, Giulia; Creamer, Rachel; Ferrari, Alessio; Fenton, Owen; Wall, David

    2018-01-01

    Soil structure is a key factor that supports all soil functions. Extracting intact soil cores and horizon specific samples for determination of soil physical parameters (e.g. bulk density (Bd) or particle size distribution) is a common practice for assessing indicators of soil structure. However,

  9. Dynamic effects of soil bulk density on denitrification and mineralisation by 15N labelled lettuce residue and paper wastes

    International Nuclear Information System (INIS)

    Hua Luo; Cheng Qing; Vinten, A.J.A.

    1997-10-01

    Two laboratory incubation experiments aimed to study the denitrification and mineralisation influenced by different additives ( 15 N labelled lettuce residue, paper wastes and mixture of both) and soil bulk densities were carried out by means of acetylene inhibition at the constant 15 degree C for 107 and 90 days, respectively. The results showed that the changes of N 2 O, CO 2 emission rates, inorganic nitrogen (NO 3 - and NH 4 + ), total N and 15 N abundance in the soils which were affected by adding lettuce residue, paper wastes and mixture of both were investigated. Soil denitrification rate increased after lettuce residue was added into soil for 8 days. The maximum rate of N 2 O emission was 15 times higher than that in soil without any additive. However, paper wastes did not increase N 2 O emission in the first 8 days compared with other treatments, mixed residue and paper wastes could promote soil microbial activity, but N 2 O emission was lower than that in the soil with lettuce residue added and higher than that with paper wastes, indicating that mixture of residue and paper wastes was benefit to soil nitrogen immobilisation. CO 2 emission in all the treatments were declined to the same level on the 107 th day. In the treatment added mixed residues and paper wastes, the released CO 2 quantities were higher than those in other treatments every day. Effect of different bulk density on N 2 O and CO 2 emission were response to the change of bulk density, it seems that N 2 O and CO 2 emission increased with bulk density. High bulk density could affect decomposition of paper wastes and NO 3 - , NH 4 + concentration. (30 ref., 10 tabs.)

  10. Porosity, Bulk Density, and Volume Reduction During Drying: Review of Measurement Methods and Coefficient Determinations

    NARCIS (Netherlands)

    Qiu, J.; Khalloufi, S.; Martynenko, A.; Dalen, van G.; Schutyser, M.A.I.; Almeida-Rivera, C.

    2015-01-01

    Several experimental methods for measuring porosity, bulk density and volume reduction during drying of foodstuff are available. These methods include among others geometric dimension, volume displacement, mercury porosimeter, micro-CT, and NMR. However, data on their accuracy, sensitivity, and

  11. The determination of the bulk density of irradiated samples using a mercury pyknometer

    International Nuclear Information System (INIS)

    Keep, R.H.; Perks, J.M.

    1980-05-01

    A method for determining the bulk density of fragmented UO 2 specimens in the mass range 1 to 10 g by mercury pyknometry has been developed. The factor limiting the accuracy of the technique in this application is the consistency with which the pyknometer can be filled with mercury; this is dependent on the vacuum obtained in the pyknometer prior to filling. It has been found that this method can be used to determine the density of fragments of UO 2 in the mass range specified to an accuracy of better than +- 0.2% (1σ). (author)

  12. A study to assess the role of bulk density of process load in "6"0Co based food irradiation facility

    International Nuclear Information System (INIS)

    Sanyal, Bhaskar; Prakasan, V.; Chawla, S.P.; Ghosh, Sunil K.

    2017-01-01

    Radiation processing of foods and allied products is one of the important techniques to extend shelf-life. The success of this technology depends on the adequate dose delivery to the food products. The absorbed doses are functions of several irradiation parameters based on the design of the facility. The variable bulk density of the process load is of paramount importance in determining the dose uniformity. Bulk densities of the product in the range of 0.01 to 0.75 gm/cc were prepared and its influence on absorbed dose was studied in a "6"0Co based food package irradiator. The results established that the bulk densities of the process loads would considerably change the absorbed doses and dose uniformity. The data would be useful to the facility operators to take adequate decision in dosimetry procedures. (author)

  13. A Semi-Analytical Extraction Method for Interface and Bulk Density of States in Metal Oxide Thin-Film Transistors.

    Science.gov (United States)

    Chen, Weifeng; Wu, Weijing; Zhou, Lei; Xu, Miao; Wang, Lei; Ning, Honglong; Peng, Junbiao

    2018-03-11

    A semi-analytical extraction method of interface and bulk density of states (DOS) is proposed by using the low-frequency capacitance-voltage characteristics and current-voltage characteristics of indium zinc oxide thin-film transistors (IZO TFTs). In this work, an exponential potential distribution along the depth direction of the active layer is assumed and confirmed by numerical solution of Poisson's equation followed by device simulation. The interface DOS is obtained as a superposition of constant deep states and exponential tail states. Moreover, it is shown that the bulk DOS may be represented by the superposition of exponential deep states and exponential tail states. The extracted values of bulk DOS and interface DOS are further verified by comparing the measured transfer and output characteristics of IZO TFTs with the simulation results by a 2D device simulator ATLAS (Silvaco). As a result, the proposed extraction method may be useful for diagnosing and characterising metal oxide TFTs since it is fast to extract interface and bulk density of states (DOS) simultaneously.

  14. A Semi-Analytical Extraction Method for Interface and Bulk Density of States in Metal Oxide Thin-Film Transistors

    Directory of Open Access Journals (Sweden)

    Weifeng Chen

    2018-03-01

    Full Text Available A semi-analytical extraction method of interface and bulk density of states (DOS is proposed by using the low-frequency capacitance–voltage characteristics and current–voltage characteristics of indium zinc oxide thin-film transistors (IZO TFTs. In this work, an exponential potential distribution along the depth direction of the active layer is assumed and confirmed by numerical solution of Poisson’s equation followed by device simulation. The interface DOS is obtained as a superposition of constant deep states and exponential tail states. Moreover, it is shown that the bulk DOS may be represented by the superposition of exponential deep states and exponential tail states. The extracted values of bulk DOS and interface DOS are further verified by comparing the measured transfer and output characteristics of IZO TFTs with the simulation results by a 2D device simulator ATLAS (Silvaco. As a result, the proposed extraction method may be useful for diagnosing and characterising metal oxide TFTs since it is fast to extract interface and bulk density of states (DOS simultaneously.

  15. Independent principal component analysis for simulation of soil water content and bulk density in a Canadian Watershed

    Directory of Open Access Journals (Sweden)

    Alaba Boluwade

    2016-09-01

    Full Text Available Accurate characterization of soil properties such as soil water content (SWC and bulk density (BD is vital for hydrologic processes and thus, it is importance to estimate θ (water content and ρ (soil bulk density among other soil surface parameters involved in water retention and infiltration, runoff generation and water erosion, etc. The spatial estimation of these soil properties are important in guiding agricultural management decisions. These soil properties vary both in space and time and are correlated. Therefore, it is important to find an efficient and robust technique to simulate spatially correlated variables. Methods such as principal component analysis (PCA and independent component analysis (ICA can be used for the joint simulations of spatially correlated variables, but they are not without their flaws. This study applied a variant of PCA called independent principal component analysis (IPCA that combines the strengths of both PCA and ICA for spatial simulation of SWC and BD using the soil data set from an 11 km2 Castor watershed in southern Quebec, Canada. Diagnostic checks using the histograms and cumulative distribution function (cdf both raw and back transformed simulations show good agreement. Therefore, the results from this study has potential in characterization of water content variability and bulk density variation for precision agriculture.

  16. LABORATORY TESTS ON INSECTICIDAL EFFECTIVENESS OF DISODIUM OCTABORATE TETRAHYDRATE, DIATOMACEOUS EARTH AND AMORPHOUS SILICA GEL AGAINST Sitophilus oryzae (L. AND THEIR EFFECT ON WHEAT BULK DENSITY

    Directory of Open Access Journals (Sweden)

    Zlatko Korunić

    2017-01-01

    Full Text Available We examined insecticide effectiveness of three different inert dusts: disodium octaborate tetrahydrate (DOT and diatomaceous earth (DE Celatom® Mn 51 applied as powder and suspension, and silica gel Sipernat® 50 S applied as powder against Sitophilus oryzae (L. and their reduction of grain bulk density. Sipernat® 50 S was the most effective dust with a very fast initial effectiveness. DE and DOT generated similar effectiveness against S. oryzae. DOT generated low initial effectiveness but after prolonged exposure time of 8 and especially after 21 days, the mortality was very high (100%, similar to the effectiveness of DE. The similar order of dusts was obtained in the reduction of wheat bulk density. Applied at dose of 200 and 500 ppm, the lowest bulk density difference in regard to bulk density of untreated wheat had DOT (-1.1 and -1.9 kg hl-1, respectively, followed by Celatom® Mn 51 (-3.5 and -4.3 kg hl-1, respectively and Sipernat® 50 S (-5.2 and -5.5 kg hl-1, respectively. Due to the effect on wheat bulk density DOT belongs to the group with the least negative effect on bulk density and therefore, it is a promising dust to control stored grain insect pests.

  17. Density functional theory study of bulk and single-layer magnetic semiconductor CrPS4

    Science.gov (United States)

    Zhuang, Houlong L.; Zhou, Jia

    2016-11-01

    Searching for two-dimensional (2D) materials with multifunctionality is one of the main goals of current research in 2D materials. Magnetism and semiconducting are certainly two desirable functional properties for a single 2D material. In line with this goal, here we report a density functional theory (DFT) study of bulk and single-layer magnetic semiconductor CrPS4. We find that the ground-state magnetic structure of bulk CrPS4 exhibits the A-type antiferromagnetic ordering, which transforms to ferromagnetic (FM) ordering in single-layer CrPS4. The calculated formation energy and phonon spectrum confirm the stability of single-layer CrPS4. The band gaps of FM single-layer CrPS4 calculated with a hybrid density functional are within the visible-light range. We also study the effects of FM ordering on the optical absorption spectra and band alignments for water splitting, indicating that single-layer CrPS4 could be a potential photocatalyst. Our work opens up ample opportunities of energy-related applications of single-layer CrPS4.

  18. Modern Theories of Pelvic Floor Support : A Topical Review of Modern Studies on Structural and Functional Pelvic Floor Support from Medical Imaging, Computational Modeling, and Electromyographic Perspectives.

    Science.gov (United States)

    Peng, Yun; Miller, Brandi D; Boone, Timothy B; Zhang, Yingchun

    2018-02-12

    Weakened pelvic floor support is believed to be the main cause of various pelvic floor disorders. Modern theories of pelvic floor support stress on the structural and functional integrity of multiple structures and their interplay to maintain normal pelvic floor functions. Connective tissues provide passive pelvic floor support while pelvic floor muscles provide active support through voluntary contraction. Advanced modern medical technologies allow us to comprehensively and thoroughly evaluate the interaction of supporting structures and assess both active and passive support functions. The pathophysiology of various pelvic floor disorders associated with pelvic floor weakness is now under scrutiny from the combination of (1) morphological, (2) dynamic (through computational modeling), and (3) neurophysiological perspectives. This topical review aims to update newly emerged studies assessing pelvic floor support function among these three categories. A literature search was performed with emphasis on (1) medical imaging studies that assess pelvic floor muscle architecture, (2) subject-specific computational modeling studies that address new topics such as modeling muscle contractions, and (3) pelvic floor neurophysiology studies that report novel devices or findings such as high-density surface electromyography techniques. We found that recent computational modeling studies are featured with more realistic soft tissue constitutive models (e.g., active muscle contraction) as well as an increasing interest in simulating surgical interventions (e.g., artificial sphincter). Diffusion tensor imaging provides a useful non-invasive tool to characterize pelvic floor muscles at the microstructural level, which can be potentially used to improve the accuracy of the simulation of muscle contraction. Studies using high-density surface electromyography anal and vaginal probes on large patient cohorts have been recently reported. Influences of vaginal delivery on the

  19. Development of floor smear sampler (floor radioactive contamination measuring instrument) for nuclear facilities

    International Nuclear Information System (INIS)

    Miyagawa, Minoru; Ito, Haruo; Nozawa, Katsuro; Shinohara, Yotaro; Hashimoto, Hiroshi.

    1980-01-01

    The control of the floor contamination with radioactive substances in nuclear facilities is strictly carried out by smear method, in which the contaminants on floor surfaces are wiped off with filter papers or cloths, and the contamination density on the floor surfaces is measured through their intensity of radioactivity. This wiping work is laborious since it is carried out in leaning-over posture when many samples must be taken in wide floor area. Therefore, to achieve labor saving in this work, an automatic sampler was developed. In the floor smear sampler developed, samples are taken on long band type wiping cloths only by handle operation, and the sample numbers are printed. When many samples are taken in wide floor area, this is especially effective, and the labor saving by 1/3 to 1/2 can be achieved. At present, this sampler is put in practical use in Hamaoka Nuclear Power Station. At the time of trial manufacture, the method of wiping, the mechanisms of wiping, cloth feeding and running, the contact pressure and the number of times of wiping affecting wiping efficiency and the required torque of a motor were examined. The developed sampler is that of constant contact pressure, vibration wiping type, and the rate of sampling is 10 sec per one sample. 100 samples can be taken on one roll of wiping cloth. The results of performance test are reported. (Kako, I.)

  20. Bulk density and aggregate stability assays in percolation columns

    Directory of Open Access Journals (Sweden)

    М. М. Хордан

    2016-12-01

    Full Text Available The restoration technologies in areas degraded by extractive activities require the use of their own mine spoils. Reducing deficiencies in physical properties, organic matter, and nutrients with a contribution of treated sewage sludge is proposed. This experiment was based on a controlled study using columns. The work was done with two mine spoils, both very rich in calcium carbonate. Two sewage sludge doses were undertaken (30,000 and 90,000 kg/ha of sewage sludge in addition to a different mine spoils used as restoration substrates. The water contribution was provided by a device that simulated short duration rain. The leached water was collected 24 hours after the last application. The experiment saw the bulk density decrease and the aggregate stability increase, thereby improving the structure. The improved soil structure decreases its vulnerability to degradation processes such as erosion and compaction.

  1. BULK THERMODYNAMICS AND CHARGE FLUCTUATIONS AT NON-VANISHING BARYON DENSITY

    International Nuclear Information System (INIS)

    MIAO, C.; SCHMIDT, C.

    2007-01-01

    We present results on bulk thermodynamic quantities as well as net baryon number, strangeness and electric charge fluctuations in QCD at non-zero density and temperature obtained from lattice calculations with almost physical quark masses for two values of the lattice cut-off aT = 1/4 and 1/6. We show that with our improved p4fa3-action the cut-off effects are under control when using lattices with a temporal extent of 6 or larger and that the contribution to the equation of state, which is due to a finite chemical potential is small for μ q /T < 1. Moreover, at vanishing chemical potential, i.e. under conditions almost realized at RHIC and the LHC, quartic fluctuations of net baryon number and strangeness are large in a narrow temperature interval characterizing the transition region from the low to high temperature phase. At non-zero baryon number density, strangeness fluctuations are enhanced and correlated to fluctuations of the net baryon number. If strangeness is furthermore forced to vanish, as it may be the case in systems created in heavy ion collisions, strangeness fluctuations are significantly smaller than baryon number fluctuations

  2. Optimising mechanical strength and bulk density of dry ceramic bodies through mixture design

    OpenAIRE

    Correia, S. L.; Hotza, D.; Segadães, A. M.

    2005-01-01

    In industrial practice, it is desirable to be able to predict, in an expeditious way, what the effects of a change in raw materials or the proportions thereof might be in the various processing steps towards the final product. When the property of interest is basically determined by the combination (or mixture) of raw materials, an optimisation methodology specific to the design of mixture experiments can be successfully used. In the present study, dry bending strength and bulk density were s...

  3. Links between matrix bulk density, macropore characteristics and hydraulic behavior of soils

    DEFF Research Database (Denmark)

    Katuwal, Sheela; Møldrup, Per; Lamandé, Mathieu

    2013-01-01

    characteristics on soil hydraulic functions has rarely been studied. With the objective of studying the links between these parameters we quantified macropore characteristics of intact soil columns (19 cm diameter x 20 cm high) from two agricultural field sites (Silstrup and Faardrup) in Denmark using coarse...... resolution X-ray CT and linked them with laboratory measurements of air permeability and leaching experiment. In addition to macropore characteristics, we also quantified the CT-number of the matrix as a measure of the bulk density of the matrix, i.e., excluding macropores in the soil. Soils from the two...

  4. Characteristic of Polymer-Impregnated Cement Mortar: Composites: Bulk Density and Microstructure

    International Nuclear Information System (INIS)

    Younes, M.M.; Abo-El-Enein, S.A.; El-Saft, M.M.; Sadek, M.A.; Zohdy, K.M.

    2010-01-01

    The effect of radiation initiated polymerization of some monomers on the physical properties of polymer-incorporated mortar was studied. The monomers used were: castor oil (C.O.), 4, 4'-diphenylmethane diisocyanate (MDI) and methyl methacrylate (MMA). Polymerization was carried out by subjecting the monomer-impregnated mortar specimens to different doses of gamma radiation. Where polyurethane (pu) and polyurethane -methyl methacrylate copolymers were formed within the pore system. The influence of polymer impregnation on the various physico-mechanical characteristics of the resulting composites was studied with respect to bulk density and polymer loading. Scanning electron microscopy (SEM) was employed to study the micro-structural characteristics of the neat hardened Ordinary Portland Cement (OPC) mortar pastes and their polymer-impregnated composites

  5. Floor interaction

    DEFF Research Database (Denmark)

    Petersen, Marianne Graves; Krogh, Peter; Ludvigsen, Martin

    2005-01-01

    Within architecture, there is a long tradition of careful design of floors. The design has been concerned with both decorating floors and designing floors to carry information. Ubiquitous computing technology offers new opportunities for designing interactive floors. This paper presents three...... different interactive floor concepts. Through an urban perspective it draws upon the experiences of floors in architecture, and provides a set of design issues for designing interactive floors....

  6. Real time monitoring of powder blend bulk density for coupled feed-forward/feed-back control of a continuous direct compaction tablet manufacturing process.

    Science.gov (United States)

    Singh, Ravendra; Román-Ospino, Andrés D; Romañach, Rodolfo J; Ierapetritou, Marianthi; Ramachandran, Rohit

    2015-11-10

    The pharmaceutical industry is strictly regulated, where precise and accurate control of the end product quality is necessary to ensure the effectiveness of the drug products. For such control, the process and raw materials variability ideally need to be fed-forward in real time into an automatic control system so that a proactive action can be taken before it can affect the end product quality. Variations in raw material properties (e.g., particle size), feeder hopper level, amount of lubrication, milling and blending action, applied shear in different processing stages can affect the blend density significantly and thereby tablet weight, hardness and dissolution. Therefore, real time monitoring of powder bulk density variability and its incorporation into the automatic control system so that its effect can be mitigated proactively and efficiently is highly desired. However, real time monitoring of powder bulk density is still a challenging task because of different level of complexities. In this work, powder bulk density which has a significant effect on the critical quality attributes (CQA's) has been monitored in real time in a pilot-plant facility, using a NIR sensor. The sensitivity of the powder bulk density on critical process parameters (CPP's) and CQA's has been analyzed and thereby feed-forward controller has been designed. The measured signal can be used for feed-forward control so that the corrective actions on the density variations can be taken before they can influence the product quality. The coupled feed-forward/feed-back control system demonstrates improved control performance and improvements in the final product quality in the presence of process and raw material variations. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Bulk density, cone index and water content relations for some Ghanian soils

    International Nuclear Information System (INIS)

    Agodzo, S.K.; Adama, I.

    2004-01-01

    Correlations were established between water content θ, bulk density ρ and cone index Δ for 4 Ghanaian soils, namely, Kumasi, Akroso, Nta and Offin series. The relationship between Δ and θ is in the form Δ = a θ 2 + b θ + c, where the correlation coefficients r 2 for the various soils were found to be very high. Similarly, Δ - ρ relationships were linear but the correlations got weaker with increasing sand content of the soil, as expected. Soil sample sizes and compaction procedures did not conform to standard procedures, yet the results did not deviate from what pertains when standard procedures are used. (author)

  8. Anisotropy and intergrain current density in oriented grained bulk YBa2Cu3Ox superconductor

    International Nuclear Information System (INIS)

    Selvamanickam, V.; Salama, K.

    1990-01-01

    The intergrain transport current density and its anisotropy have been studied in oriented grained bulk YBa 2 Cu 3 O x superconductors fabricated by the liquid phase processing method. Current density measurements were performed on oriented grained samples with the transport current aligned at different angles to the a-b plane. In these measurements, the transport current passed through several oriented grain boundaries. The results indicate that the critical current density drops rapidly when the transport current flows at small angles to the a-b plane and then decreases slowly at larger angles. At 77 K and zero magnetic field, an anisotropy ratio of about 25 is observed between J c along a-b plane and that perpendicular to the plane. Further, the critical current density in these samples is found to depend weakly on magnetic field even though the current crosses grain boundaries. These results support the notion that grain boundaries of these superconductors are different in nature from those of solid-state sintered samples.

  9. Perceived floor slipperiness and floor roughness in a gait experiment.

    Science.gov (United States)

    Yu, Ruifeng; Li, Kai Way

    2015-01-01

    Slips and falls contribute to occupational injuries and fatalities globally. Both floor slipperiness and floor roughness affect the occurrence of slipping and falling. Investigations on fall-related phenomena are important for the safety and health of workers. The purposes of this study were to: compare the perceived floor slipperiness before and after walking on the floor; compare the perceived floor slipperiness with and without shoes for males and females; discuss the perceived floor roughness based on barefoot walking; and establish regression models to describe the relationship between perceived floor slipperiness and actual friction of the floors. Male and female subjects walked on 3 m walkways with or without shoes. The perceived floor slipperiness ratings both before and after their walk were collected. The perceived floor slipperiness both before and after walking were significantly affected by both floor and surface conditions. Gender, floor, surface, and footwear conditions were all significant factors affecting the adjustment of perceived floor slipperiness. The subjects made more adjustment on perceived floor slipperiness rating when they had shoes on than when they were barefooted. Regression models were established to describe the relationship between perceived floor slipperiness and floor coefficient of friction. These models may be used to estimate perceived floor slipperiness, or in reverse, the coefficient of friction of the floor, so as to prevent slipping and falling in workplaces.

  10. Effect of cocoa bran on low-density lipoprotein oxidation and fecal bulking.

    Science.gov (United States)

    Jenkins, D J; Kendall, C W; Vuksan, V; Vidgen, E; Wong, E; Augustin, L S; Fulgoni, V

    Legumes have reported benefits in terms of reduced risk for coronary heart disease and of colonic health. A novel legume fiber, cocoa bran, also may have favorable health effects on serum lipid levels, low-density lipoprotein (LDL) cholesterol oxidation, and fecal bulk. Twenty-five healthy normolipidemic subjects (13 men and 12 women) (mean +/- SEM age, 37 +/- 2 years; mean +/- SEM body mass index [calculated as weight in kilograms divided by the square of height in meters], 24.6 +/- 0.7) ate cocoa-bran and chocolate-flavored low-fiber breakfast cereals for 2-week periods, with 2-week washout, in a double-blind crossover study. The cocoa-bran cereal provided 25.0 g/d of total dietary fiber (TDF). The low-fiber cereal (5.6 g/d TDF) was of similar appearance and energy value. Fasting blood samples were obtained at the start and end of each period, and 4-day fecal collections were made from days 11 through 14. High-density lipoprotein (HDL) cholesterol level was higher (7.6% +/- 2.9%; P =.02) and the LDL/HDL cholesterol ratio was lower (6.7% +/- 2.3%; P =.007) for cocoa-bran compared with low-fiber cereal at 2 weeks. No effect was seen on LDL cholesterol oxidation. Mean fecal output was significantly higher for cocoa-bran than for low-fiber cereal (56 +/- 14 g/d; Pchocolate-flavored cocoa-bran cereal increased fecal bulk similarly to wheat bran and was associated with a reduction in the LDL/HDL cholesterol ratio. In view of the low-fat, high-fiber nature of the material, these results suggest a possible role for this novel fiber source in the diets of normal, hyperlipidemic, and constipated subjects.

  11. Impact of Molecular Orientation and Packing Density on Electronic Polarization in the Bulk and at Surfaces of Organic Semiconductors

    KAUST Repository

    Ryno, Sean

    2016-05-16

    The polarizable environment surrounding charge carriers in organic semiconductors impacts the efficiency of the charge transport process. Here, we consider two representative organic semiconductors, tetracene and rubrene, and evaluate their polarization energies in the bulk and at the organic-vacuum interface using a polarizable force field that accounts for induced-dipole and quadrupole interactions. Though both oligoacenes pack in a herringbone motif, the tetraphenyl substituents on the tetracene backbone of rubrene alter greatly the nature of the packing. The resulting change in relative orientations of neighboring molecules is found to reduce the bulk polarization energy of holes in rubrene by some 0.3 eV when compared to tetracene. The consideration of model organic-vacuum interfaces highlights the significant variation in the electrostatic environment for a charge carrier at a surface although the net change in polarization energy is small; interestingly, the environment of a charge even just one layer removed from the surface can be viewed already as representative of the bulk. Overall, it is found that in these herringbone-type layered crystals the polarization energy has a much stronger dependence on the intralayer packing density than interlayer packing density.

  12. Predictive Simulation of Process Windows for Powder Bed Fusion Additive Manufacturing: Influence of the Powder Bulk Density.

    Science.gov (United States)

    Rausch, Alexander M; Küng, Vera E; Pobel, Christoph; Markl, Matthias; Körner, Carolin

    2017-09-22

    The resulting properties of parts fabricated by powder bed fusion additive manufacturing processes are determined by their porosity, local composition, and microstructure. The objective of this work is to examine the influence of the stochastic powder bed on the process window for dense parts by means of numerical simulation. The investigations demonstrate the unique capability of simulating macroscopic domains in the range of millimeters with a mesoscopic approach, which resolves the powder bed and the hydrodynamics of the melt pool. A simulated process window reveals the influence of the stochastic powder layer. The numerical results are verified with an experimental process window for selective electron beam-melted Ti-6Al-4V. Furthermore, the influence of the powder bulk density is investigated numerically. The simulations predict an increase in porosity and surface roughness for samples produced with lower powder bulk densities. Due to its higher probability for unfavorable powder arrangements, the process stability is also decreased. This shrinks the actual parameter range in a process window for producing dense parts.

  13. Estimating canopy bulk density and canopy base height for conifer stands in the interior Western United States using the Forest Vegetation Simulator Fire and Fuels Extension.

    Science.gov (United States)

    Seth Ex; Frederick Smith; Tara Keyser; Stephanie Rebain

    2017-01-01

    The Forest Vegetation Simulator Fire and Fuels Extension (FFE-FVS) is often used to estimate canopy bulk density (CBD) and canopy base height (CBH), which are key indicators of crown fire hazard for conifer stands in the Western United States. Estimated CBD from FFE-FVS is calculated as the maximum 4 m running mean bulk density of predefined 0.3 m thick canopy layers (...

  14. Determination of mass density, dielectric, elastic, and piezoelectric constants of bulk GaN crystal.

    Science.gov (United States)

    Soluch, Waldemar; Brzozowski, Ernest; Lysakowska, Magdalena; Sadura, Jolanta

    2011-11-01

    Mass density, dielectric, elastic, and piezoelectric constants of bulk GaN crystal were determined. Mass density was obtained from the measured ratio of mass to volume of a cuboid. The dielectric constants were determined from the measured capacitances of an interdigital transducer (IDT) deposited on a Z-cut plate and from a parallel plate capacitor fabricated from this plate. The elastic and piezoelectric constants were determined by comparing the measured and calculated SAW velocities and electromechanical coupling coefficients on the Z- and X-cut plates. The following new constants were obtained: mass density p = 5986 kg/m(3); relative dielectric constants (at constant strain S) ε(S)(11)/ε(0) = 8.6 and ε(S)(11)/ε(0) = 10.5, where ε(0) is a dielectric constant of free space; elastic constants (at constant electric field E) C(E)(11) = 349.7, C(E)(12) = 128.1, C(E)(13) = 129.4, C(E)(33) = 430.3, and C(E)(44) = 96.5 GPa; and piezoelectric constants e(33) = 0.84, e(31) = -0.47, and e(15) = -0.41 C/m(2).

  15. Effect of sample moisture and bulk density on performance of the 241Am-Be source based prompt gamma rays neutron activation analysis setup. A Monte Carlo study

    International Nuclear Information System (INIS)

    Almisned, Ghada

    2010-01-01

    Monte Carlo simulations were carried out using the dependence of gamma ray yield on the bulk density and moisture content for five different lengths of Portland cement samples in a thermal neutron capture based Prompt Gamma ray Neutron Activation Analysis (PGNAA) setup for source inside moderator geometry using an 241 Am-Be neutron source. In this study, yields of 1.94 and 6.42 MeV prompt gamma rays from calcium in the five Portland cement samples were calculated as a function of sample bulk density and moisture content. The study showed a strong dependence of the 1.94 and 6.42 MeV gamma ray yield upon the sample bulk density but a weaker dependence upon sample moisture content. For an order of magnitude increase in the sample bulk density, an order of magnitude increase in the gamma rays yield was observed, i.e., a one-to-one correspondence. In case of gamma ray yield dependence upon sample moisture content, an order of magnitude increase in the moisture content of the sample resulted in about 16-17% increase in the yield of 1.94 and 6.42 MeV gamma rays from calcium. (author)

  16. Gamma-ray attenuation to measure water contents and/or bulk densities of porous materials

    International Nuclear Information System (INIS)

    Ferraz, E.S.B.

    1983-01-01

    Attenuation of gamma radiation during transmission through soil and porous materials has been used for approximately three decades as a method for determining volumetric water content, theta, and bulk density, rho. This method is particularly suited for laboratory determinations of theta and rho in soil columns but it also has been used with success under field conditions. Measurements of attentuation of a collimated beam of monoernergetic gamma-rays has been used successfully by many investigators to provide rapid, non-destructive determinations for small volumes of soil. For stable soils, i.e. soils which do not swell upon wetting or shrink upon drying, rho may be assumed to remain constant during water flow through the soil, and thus changes in intensity or transmitted radiation may be attributed to changes in water content, theta. However, for unstable soils, the dry bulk density is subject to change with time during water flow through the soil and cannot be assumed to be a constant. Several investigators have utilized either a single beam of dual-energy gamma photons or two separate monoenergetic photon beams with greatly different energies to simultaneously determine theta and rho in these soils. A general review of gamma-ray attenuation methods for determining theta and rho in laboratory soil cores and in field soil profiles is reported in this paper. Theoretical equations for transmission and attenuation of gamma radiation in soils are presented for both single and double beams of gamma photons. Sensitivity, precision, accuracy, and experimental errors for the method are evaluated and discussed with respect to the theory. (author)

  17. Mechanical decontamination techniques for floor drain systems

    International Nuclear Information System (INIS)

    Palau, G.L.

    1987-01-01

    The unprecedented nature of cleanup activities at Three Mile Island Unit 2 (TMI-2) following the 1979 accident has necessitated the development of new techniques to deal with radiation and contamination in the plant. One of these problems was decontamination of floor drain systems, which had become highly contaminated with various forms of dirt and sludge containing high levels of fission products and fuel from the damaged reactor core. The bulk of this contamination is loosely adherent to the drain pipe walls; however, significant amounts of contamination have become incorporated into pipe wall oxide and corrosion layers and embedded in microscopic pits and fissures in the pipe wall material. The need to remove this contamination was recognized early in the TMI-2 cleanup effort. A program consisting of development and laboratory testing of floor drain decontamination techniques was undertaken early in the cleanup with support from the Electric Power Research Institute (EPRI). Based on this initial research, two techniques were judged to show promise for use at TMI-2: a rotating brush hone system and a high-pressure water mole nozzle system. Actual use of these devices to clean floor drains at TMI-2 has yielded mixed decontamination results. The decontamination effectiveness that has been obtained is highly dependent on the nature of the contamination in the drain pipe and the combination of decontamination techniques used

  18. Exact probability function for bulk density and current in the asymmetric exclusion process

    Science.gov (United States)

    Depken, Martin; Stinchcombe, Robin

    2005-03-01

    We examine the asymmetric simple exclusion process with open boundaries, a paradigm of driven diffusive systems, having a nonequilibrium steady-state transition. We provide a full derivation and expanded discussion and digression on results previously reported briefly in M. Depken and R. Stinchcombe, Phys. Rev. Lett. 93, 040602 (2004). In particular we derive an exact form for the joint probability function for the bulk density and current, both for finite systems, and also in the thermodynamic limit. The resulting distribution is non-Gaussian, and while the fluctuations in the current are continuous at the continuous phase transitions, the density fluctuations are discontinuous. The derivations are done by using the standard operator algebraic techniques and by introducing a modified version of the original operator algebra. As a by-product of these considerations we also arrive at a very simple way of calculating the normalization constant appearing in the standard treatment with the operator algebra. Like the partition function in equilibrium systems, this normalization constant is shown to completely characterize the fluctuations, albeit in a very different manner.

  19. The Relations Between Soil Water Retention Characteristics, Particle Size Distributions, Bulk Densities and Calcium Carbonate Contents for Danish Soils

    DEFF Research Database (Denmark)

    Jensen, Niels H.; Balstrøm, Thomas; Breuning-Madsen, Henrik

    2005-01-01

    functions developed in HYPRES (Hydraulic Properties of European Soils). Introducing bulk density as a predictor improved the equation for pressure head –1 kPa but not for lower ones. The grouping of data sets in surface and subsurface horizons or in textural classes did not improve the equations. Based...

  20. Soil Aggregation, Organic Carbon Concentration, and Soil Bulk Density As Affected by Cover Crop Species in a No-Tillage System

    Directory of Open Access Journals (Sweden)

    Adriano Stephan Nascente

    2015-06-01

    Full Text Available Soil aggregation and the distribution of total organic carbon (TOC may be affected by soil tillage and cover crops. The objective of this study was to determine the effects of crop rotation with cover crops on soil aggregation, TOC concentration in the soil aggregate fractions, and soil bulk density under a no-tillage system (NTS and conventional tillage system (CTS, one plowing and two disking. This was a three-year study with cover crop/rice/cover crop/rice rotations in the Brazilian Cerrado. A randomized block experimental design with six treatments and three replications was used. The cover crops (treatments were: fallow, Panicum maximum, Brachiaria ruziziensis, Brachiaria brizantha, and millet (Pennisetum glaucum. An additional treatment, fallow plus CTS, was included as a control. Soil samples were collected at the depths of 0.00-0.05 m, 0.05-0.10 m, and 0.10-0.20 m after the second rice harvest. The treatments under the NTS led to greater stability in the soil aggregates (ranging from 86.33 to 95.37 % than fallow plus CTS (ranging from 74.62 to 85.94 %. Fallow plus CTS showed the highest number of aggregates smaller than 2 mm. The cover crops affected soil bulk density differently, and the millet treatment in the NTS had the lowest values. The cover crops without incorporation provided the greatest accumulation of TOC in the soil surface layers. The TOC concentration was positively correlated with the aggregate stability index in all layers and negatively correlated with bulk density in the 0.00-0.10 m layer.

  1. SUSTAINABLE TRAILER FLOORING

    Directory of Open Access Journals (Sweden)

    John Lu

    2009-05-01

    Full Text Available Different trailer flooring materials, including wood-based, aluminum, steel, and synthetic plastic floors, were evaluated in accordance with their durability and sustainability to our natural environment. Wood-based trailer flooring is an eco-friendly product. It is the most sustainable trailer flooring material compared with fossil fuel-intensive steel, aluminum, and plastics. It is renewable and recyclable. Oak, hard maple, and apitong are strong and durable hardwood species that are currently extensively used for trailer flooring. For manufacture, wood-based flooring is higher in energy efficiency and lower in carbon emission than steel, aluminum and plastics. Moreover, wood per se is a natural product that sequesters carbon. Accordingly, using more wood-based trailer flooring is effective to reduce global warming.

  2. Transforming Pinus pinaster forest to recreation site: preliminary effects on LAI, some forest floor, and soil properties.

    Science.gov (United States)

    Öztürk, Melih; Bolat, İlyas

    2014-04-01

    This study investigates the effects of forest transformation into recreation site. A fragment of a Pinus pinaster plantation forest was transferred to a recreation site in the city of Bartın located close to the Black Sea coast of northwestern Turkey. During the transformation, some of the trees were selectively removed from the forest to generate more open spaces for the recreationists. As a result, Leaf Area Index (LAI) decreased by 0.20 (about 11%). Additionally, roads and pathways were introduced into the site together with some recreational equipment sealing parts of the soil surface. Consequently, forest environment was altered with a semi-natural landscape within the recreation site. The purpose of this study is to assess the effects of forest transformation into recreation site particularly in terms of the LAI parameter, forest floor, and soil properties. Preliminary monitoring results indicate that forest floor biomass is reduced by 26% in the recreation site compared to the control site. Soil temperature is increased by 15% in the recreation site where selective removal of trees expanded the gaps allowing more light transmission. On the other hand, the soil bulk density which is an indicator of soil compaction is unexpectedly slightly lower in the recreation site. Organic carbon (C(org)) and total nitrogen (N(total)) together with the other physical and chemical parameter values indicate that forest floor and soil have not been exposed to much disturbance. However, subsequent removal of trees that would threaten the vegetation, forest floor, and soil should not be allowed. The activities of the recreationists are to be concentrated on the paved spaces rather than soil surfaces. Furthermore, long-term monitoring and management is necessary for both the observation and conservation of the site.

  3. Floors: Selection and Maintenance.

    Science.gov (United States)

    Berkeley, Bernard

    Flooring for institutional, commercial, and industrial use is described with regard to its selection, care, and maintenance. The following flooring and subflooring material categories are discussed--(1) resilient floor coverings, (2) carpeting, (3) masonry floors, (4) wood floors, and (5) "formed-in-place floors". The properties, problems,…

  4. Acoustics advances study of sea floor hydrothermal flow

    Science.gov (United States)

    Rona, Peter A.; Jackson, Darrell R.; Bemis, Karen G.; Jones, Christopher D.; Mitsuzawa, Kyohiko; Palmer, David R.; Silver, Deborah

    Sub-sea floor hydrothermal convection systems discharge as plumes from point sources and as seepage from the ocean bottom. The plumes originate as clear, 150-400°C solutions that vent from mineralized chimneys; precipitate dissolved metals as particles to form black or white smokers as they turbulently mix with ambient seawater; and buoyantly rise hundreds of meters to a level of neutral density where they spread laterally. The seepage discharges from networks of fractures at the rock-water interface as clear, diffuse flow, with lower temperatures, metal contents, and buoyancy than the smokers. The diffuse flow may be entrained upward into plumes, or laterally by prevailing currents in discrete layers within tens of meters of the sea floor. The role of these flow regimes in dispersing heat, chemicals, and biological material into the ocean from sub-sea floor hydrothermal convection systems is being studied on a global scale.

  5. Gamma-ray yield dependence on bulk density and moisture content of a sample of a PGNAA setup. A Monte Carlo study

    International Nuclear Information System (INIS)

    Nagadi, M.M.; Naqvi, A.A.

    2007-01-01

    Monte Carlo calculations were carried out to study the dependence of γ-ray yield on the bulk density and moisture content of a sample in a thermalneutron capture-based prompt gamma neutron activation analysis (PGNAA) setup. The results of the study showed a strong dependence of the γ-ray yield upon the sample bulk density. An order of magnitude increase in yield of 1.94 and 6.42 MeV prompt γ-rays from calcium in a Portland cement sample was observed for a corresponding order of magnitude increase in the sample bulk density. On the contrary the γ-ray yield has a weak dependence on sample moisture content and an increase of only 20% in yield of 1.94 and 6.42 MeV prompt γ-rays from calcium in the Portland cement sample was observed for an order of magnitude increase in the moisture content of the Portland cement sample. A similar effect of moisture content has been observed on the yield of 1.167 MeV prompt γ-rays from chlorine contaminants in Portland cement samples. For an order of magnitude increase in the moisture content of the sample, a 7 to 12% increase in the yield of the 1.167 MeV chlorine γ-ray was observed for the Portland cement samples containing 1 to 5 wt.% chlorine contaminants. This study has shown that effects of sample moisture content on prompt γ-ray yield from constituents of a Portland cement sample are insignificant in a thermal-neutrons capture-based PGNAA setup. (author)

  6. Comparison of survivability of Staphylococcus aureus and spores of Aspergillus niger on commonly used floor materials.

    Science.gov (United States)

    Gupta, Mridula; Bisesi, Michael; Lee, Jiyoung

    2017-07-01

    The survivability of Staphylococcus aureus and spores of Aspergillus niger was compared on 5 common floor materials. Floor materials were inoculated with a known concentration of S aureus and spores of A niger on day 0. Their survivability was measured on days, 2, 7, 14, and 28 by bulk rinsate method and enumerated using culture-based method. The difference in change of S aureus levels was statistically significant for all tested days (P niger spores were undetected on residential broadloom carpet and rubber-backed commercial carpet after day 2 but survived on VCT, PT, and wood until day 28. Floor materials with hard and smooth surfaces, such as VCT and PT, can allow survival of S aureus and A niger for up to 4 weeks. It may imply that floor materials can play a major role in preserving microbial contaminants in the built environment. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  7. [Characteristics of floor litter and soil arthropod community in different types ot subtropical forest in Ailao Mountain of Yunnan, Southwest China].

    Science.gov (United States)

    Yang, Zhao; Yang, Xiao-Dong

    2011-11-01

    By using line transect method, an investigation was conducted on the floor litter and soil arthropod community in a mid mountain wet evergreen broad-leaved forest, a mossy dwarf forest, and a Populus bonatii forest in Ailao Mountain of Yunnan in April (dry and hot season), June (rainy season), and December (dry and cold season), 2005. In both dry and rainy seasons, the existing floor litter mass, C storage, and C/N ratio in the three forests all increased in the order of mossy dwarf forest > P. bonatii forest > evergreen broad-leaved forest, but the N storage had less difference. In the floor litter layer of the forests, Acari and Collembola were the dominant groups of soil arthropod community, while Diptera larvae, Coleoptera, ants, and Homoptera were the common groups. The Sorenson coefficients of soil arthropod community in the three forests were extremely great. No significant differences were observed in the soil arthropod density (ind x m(-2)) in the floor litter layer among the three forests, but the relative density (ind x g(-1)) of soil arthropods was higher in the evergreen broad-leaved forest and P. bonatii forest than in the mossy dwarf forest. In the three forests, the density of soil arthropods was significantly higher in dry season than in rainy season, but the Shannon diversity index had less difference. There were significant positive correlations between the existing floor litter mass and the individual density (ind x m(-2)) and dominant groups of soil arthropod communities in dry and hot season (April), but negative correlations between the existing floor litter mass and the relative density (ind x g(-1)) of soil arthropod communities and Acari in dry and cold season (December). The individual densities of Collembola and Coleoptera also had positive correlations with the N storage of the existing floor litter mass in the three forests. It was considered that the floor litter and the development of soil arthropod community in the litter layer of

  8. Density functional theory study of inter-layer coupling in bulk tin selenide

    Science.gov (United States)

    Song, Hong-Yue; Lü, Jing-Tao

    2018-03-01

    We study the inter-layer coupling in bulk tin selenide (SnSe) through density functional theory based calculations. Different approximations for the exchange-correlation functionals and the van der Waals interaction are employed. By performing comparison with graphite, MoS2 and black phosphorus, we analyze the inter-layer coupling from different points of view, including the binding energy, the low frequency inter-layer optical phonons, and the inter-layer charge transfer. We find that, there is a strong charge transfer between layers of SnSe, resulting in the strongest inter-layer coupling. Moreover, the charge transfer renders the inter-layer coupling in SnSe not of van der Waals type. Mechanical exfoliation has been used to fabricate mono- or few-layer graphene, MoS2 and black phosphorus. But, our results show that it may be difficult to apply similar technique to SnSe.

  9. The Effect of Age, Stocking Density and Flooring during Transport on Welfare of Young Dairy Calves in Australia

    Directory of Open Access Journals (Sweden)

    Ellen C. Jongman

    2014-04-01

    Full Text Available Transport of young (‘bobby’ calves for slaughter is a contentious welfare issue for some sectors of the Australian community. Factors of age, stocking density and flooring need further research to develop appropriate welfare standards for transport of bobby calves. The objective of this study was to identify the space allowance requirements for transport of bobby calves and to understand factors such as age and flooring that minimise risks to calf welfare during transport. Animals aged 3-, 5- and 10-day old were transported for 12 h in a custom-made cattle truck fitted with 9 pens, with movable mesh divisions. Each pen contained 4 calves, with space allowances of 0.2, 0.3 and 0.5 m2 per calf and flooring of solid metal, mesh or straw bedding. A total of 432 male dairy calves were transported in 12 trips during the 2-year study. Behavioural measurements included lying during transport, and lying and drinking for 12 h after transport during recovery. Blood samples were taken prior to transport, immediately after transport and 12 h after transport. Blood samples were analysed for metabolic state (glucose, beta-hydroxy-butyrate (BOHB, hydration (packed cell volume (PCV and exhaustion/bruising (creatine kinase (CK activity. It was found that several measures were affected by age, which indicates that the physiology and in particular lying behaviour of 3-day old calves is fundamentally different from that of older calves. It is unclear how this affects their ability to cope with the stressors of transport. Space affected the posture changes and CK activity during and after transport and it is concluded that space allowance should be at least 0.3 m2 per calf for calves of average size, while CK activity suggested that providing more space to 0.5 m2 per calf may provide even greater benefits. Straw bedding is of clear benefit to calves during transport, to the extent that it may even reduce some of the negative effects of reduced space on lying

  10. Pelvic floor muscle function in women with pelvic floor dysfunction

    DEFF Research Database (Denmark)

    Tibaek, Sigrid; Dehlendorff, Christian

    2014-01-01

    The objectives of this study were to investigate the level of pelvic floor muscle (PFM) function in women with pelvic floor dysfunction (PFD) referred by gynaecologists and urologists for in-hospital pelvic floor muscle training (PFMT), and to identity associated factors for a low level of PFM...

  11. SUSTAINABLE TRAILER FLOORING

    OpenAIRE

    John Lu; Marc Chorney; Lowell Peterson

    2009-01-01

    Different trailer flooring materials, including wood-based, aluminum, steel, and synthetic plastic floors, were evaluated in accordance with their durability and sustainability to our natural environment. Wood-based trailer flooring is an eco-friendly product. It is the most sustainable trailer flooring material compared with fossil fuel-intensive steel, aluminum, and plastics. It is renewable and recyclable. Oak, hard maple, and apitong are strong and durable hardwood species that are curren...

  12. Bulk Building Material Characterization and Decontamination Using a Concrete Floor and Wall Contamination Profiling Technology

    International Nuclear Information System (INIS)

    Aggarwal, S.; Charters, G.; Blauvelt, D.

    2002-01-01

    The concrete profiling technology, RadPro(trademark) has four major components: a drill with a specialized cutting and sampling head, drill bits, a sample collection unit and a vacuum pump. The equipment in conjunction with portable radiometric instrumentation produces a profile of radiological or chemical contamination through the material being studied. The drill head is used under hammer action to penetrate hard surfaces. This causes the bulk material to be pulverized as the drill travels through the radioactive media efficiently transmitting to the sampling unit a representative sample of powdered bulk material. The profiling equipment is designed to sequentially collect all material from the hole. The bulk material samples are continuously retrieved by use of a specially designed vacuumed sample retrieval unit that prevents cross contamination of the clean retrieved samples. No circulation medium is required with this profiling process; therefore, the only by-product from drilling is the sample. The data quality, quantity, and representativeness may be used to produce an activity profile from the hot spot surface into the bulk building material. The activity data obtained during the profiling process is reduced and transferred to building drawings as part of a detailed report of the radiological problem. This activity profile may then be expanded to ultimately characterize the facility and expedite waste segregation and facility closure at a reduced cost and risk

  13. The impact of compaction, moisture content, particle size and type of bulking agent on initial physical properties of sludge-bulking agent mixtures before composting.

    Science.gov (United States)

    Huet, J; Druilhe, C; Trémier, A; Benoist, J C; Debenest, G

    2012-06-01

    This study aimed to experimentally acquire evolution profiles between depth, bulk density, Free Air Space (FAS), air permeability and thermal conductivity in initial composting materials. The impact of two different moisture content, two particle size and two types of bulking agent on these four parameters was also evaluated. Bulk density and thermal conductivity both increased with depth while FAS and air permeability both decreased with it. Moreover, depth and moisture content had a significant impact on almost all the four physical parameters contrary to particle size and the type of bulking agent. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Developmental morphology of cover crop species exhibit contrasting behaviour to changes in soil bulk density, revealed by X-ray computed tomography.

    Science.gov (United States)

    Burr-Hersey, Jasmine E; Mooney, Sacha J; Bengough, A Glyn; Mairhofer, Stefan; Ritz, Karl

    2017-01-01

    Plant roots growing through soil typically encounter considerable structural heterogeneity, and local variations in soil dry bulk density. The way the in situ architecture of root systems of different species respond to such heterogeneity is poorly understood due to challenges in visualising roots growing in soil. The objective of this study was to visualise and quantify the impact of abrupt changes in soil bulk density on the roots of three cover crop species with contrasting inherent root morphologies, viz. tillage radish (Raphanus sativus), vetch (Vicia sativa) and black oat (Avena strigosa). The species were grown in soil columns containing a two-layer compaction treatment featuring a 1.2 g cm-3 (uncompacted) zone overlaying a 1.4 g cm-3 (compacted) zone. Three-dimensional visualisations of the root architecture were generated via X-ray computed tomography, and an automated root-segmentation imaging algorithm. Three classes of behaviour were manifest as a result of roots encountering the compacted interface, directly related to the species. For radish, there was switch from a single tap-root to multiple perpendicular roots which penetrated the compacted zone, whilst for vetch primary roots were diverted more horizontally with limited lateral growth at less acute angles. Black oat roots penetrated the compacted zone with no apparent deviation. Smaller root volume, surface area and lateral growth were consistently observed in the compacted zone in comparison to the uncompacted zone across all species. The rapid transition in soil bulk density had a large effect on root morphology that differed greatly between species, with major implications for how these cover crops will modify and interact with soil structure.

  15. Standard Test Method for Water Absorption, Bulk Density, Apparent Porosity, and Apparent Specific Gravity of Fired Whiteware Products

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method covers procedures for determining water absorption, bulk density, apparent porosity, and apparent specific gravity of fired unglazed whiteware products. 1.2 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  16. Pressure-Dependent Electronic and Transport Properties of Bulk Platinum Oxide by Density Functional Theory

    Science.gov (United States)

    Kansara, Shivam; Gupta, Sanjeev K.; Sonvane, Yogesh; Nekrasov, Kirill A.; Kichigina, Natalia V.

    2018-02-01

    The structural, electronic, and vibrational properties of bulk platinum oxide (PtO) at compressive pressures in the interval from 0 GPa to 35 GPa are investigated using the density functional theory. The calculated electronic band structure of PtO shows poor metallicity at very low density of states on the Fermi level. However, the hybrid pseudopotential calculation yielded 0.78 eV and 1.30 eV direct band and indirect gap, respectively. Importantly, our results predict that PtO has a direct band gap within the framework of HSE06, and it prefers equally zero magnetic order at different pressures. In the Raman spectra, peaks are slightly shifted towards higher frequency with the decrease in pressure. We have also calculated the thermoelectric properties, namely the electronic thermal conductivity and electrical conductivity, with respect to temperature and thermodynamic properties such as entropy, specific heat at constant volume, enthalpy and Gibbs free energy with respect to pressure. The result shows that PtO is a promising candidate for use as a catalyst, in sensors, as a photo-cathode in water electrolysis, for thermal decomposition of inorganic salt and fuel cells.

  17. Correlations Between Magnetic Flux and Levitation Force of HTS Bulk Above a Permanent Magnet Guideway

    Science.gov (United States)

    Huang, Huan; Zheng, Jun; Zheng, Botian; Qian, Nan; Li, Haitao; Li, Jipeng; Deng, Zigang

    2017-10-01

    In order to clarify the correlations between magnetic flux and levitation force of the high-temperature superconducting (HTS) bulk, we measured the magnetic flux density on bottom and top surfaces of a bulk superconductor while vertically moving above a permanent magnet guideway (PMG). The levitation force of the bulk superconductor was measured simultaneously. In this study, the HTS bulk was moved down and up for three times between field-cooling position and working position above the PMG, followed by a relaxation measurement of 300 s at the minimum height position. During the whole processes, the magnetic flux density and levitation force of the bulk superconductor were recorded and collected by a multipoint magnetic field measurement platform and a self-developed maglev measurement system, respectively. The magnetic flux density on the bottom surface reflected the induced field in the superconductor bulk, while on the top, it reveals the penetrated magnetic flux. The results show that the magnetic flux density and levitation force of the bulk superconductor are in direct correlation from the viewpoint of inner supercurrent. In general, this work is instructive for understanding the connection of the magnetic flux density, the inner current density and the levitation behavior of HTS bulk employed in a maglev system. Meanwhile, this magnetic flux density measurement method has enriched present experimental evaluation methods of maglev system.

  18. Polypropylene Darning: A New Alternative for Reconstruction of Orbital Floor after Total Maxillectomy.

    Science.gov (United States)

    Sharma, Prashant

    2015-06-01

    Removal of orbital floor is an integral part of total (radical) maxillectomy (type IIIa), which if not managed properly, may lead to some eye related distressing complications like diplopia, eyelid malposition, epiphora, dacryocystitis, enopthalmos and ectoprion. Among all, diplopia is the most distressing complication which hampers daily activity. Various options for orbital floor reconstruction are available like titanium sheet, polypropylene mesh, non-vascularized or vascularized bone graft, pedicled flaps, micro-vascular free flaps, prosthesis placement, and split skin graft followed by obturator placement. Till date no-body has tried stabilization of eye ball by 'darning' the orbital floor using non-absorbable suture. 'Polypropylene suture darning' is an easy to learn, novel method with equally good results. Five patients with potentially resectable tumors underwent total maxillectomy. I used polypropylene 3-0 round body suture and 'darning' was done at orbital floor, incorporating periosteum (if remaining) and peri-orbital fat into the sutures. Muscle flaps were done to provide bulk and palatal reconstruction. Assessment of patients was done post-operatively at day-5 i.e., before discharge and at 1 month after surgery, and also in further follow up visits. The results were very good in terms of clear vision & eye movements (directly related to 'darning'), and the aesthetic look of patients and bilateral symmetry were satisfactory (not related to darning). Darning of orbital floor by polypropylene after total maxillectomy is an easy to learn and cost-effective method of reconstruction with good results.

  19. Solving decontaminable flooring problems

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    Pennsylvania Power and Light wanted to cover deteriorating concrete in unit 2 of its Susquehanna BWR with a smooth, durable, decontaminable coating. Traditionally, floors in the plant had been coated with epoxy paint, but many of these floors suffered delamination, and failed in three to five years. Painting with epoxy would also interrupt operations for as much as three days while the floor dried, yet critical instruments in some areas had to be monitored at least once per shift. In addition, conventional floor surface preparation produced dust and vibration around sensitive equipment. The solution was a dustless scabbling system for surface preparation, followed by the installation of a high-strength acrylic industrial floor known as Silakal. The work was carried out by Pentek. Silikal bonds to the underlying concrete, so that delamination of the floor will not occur even under severe traffic conditions. Another advantage of this type of flooring is that it cures in one hour, so floor resurfacing has only minimal impact on plant operations. (author)

  20. Systematic evaluations of probabilistic floor response spectrum generation

    International Nuclear Information System (INIS)

    Lilhanand, K.; Wing, D.W.; Tseng, W.S.

    1985-01-01

    The relative merits of the current methods for direct generation of probabilistic floor response spectra (FRS) from the prescribed design response spectra (DRS) are evaluated. The explicit probabilistic methods, which explicitly use the relationship between the power spectral density function (PSDF) and response spectra (RS), i.e., the PSDF-RS relationship, are found to have advantages for practical applications over the implicit methods. To evaluate the accuracy of the explicit methods, the root-mean-square (rms) response and the peak factor contained in the PSDF-RS relationship are systematically evaluated, especially for the narrow-band floor spectral response, by comparing the analytical results with simulation results. Based on the evaluation results, a method is recommended for practical use for the direct generation of probabilistic FRS. (orig.)

  1. Electrical method for the measurements of volume averaged electron density and effective coupled power to the plasma bulk

    Science.gov (United States)

    Henault, M.; Wattieaux, G.; Lecas, T.; Renouard, J. P.; Boufendi, L.

    2016-02-01

    Nanoparticles growing or injected in a low pressure cold plasma generated by a radiofrequency capacitively coupled capacitive discharge induce strong modifications in the electrical parameters of both plasma and discharge. In this paper, a non-intrusive method, based on the measurement of the plasma impedance, is used to determine the volume averaged electron density and effective coupled power to the plasma bulk. Good agreements are found when the results are compared to those given by other well-known and established methods.

  2. Introductory guide to floors and flooring

    CSIR Research Space (South Africa)

    Billingham, PA

    1977-01-01

    Full Text Available not make use of the warming and cooling effects of direct contact with the ground. Indeed the precautions that are necessary to protect such floors against damp and decay may actually reduce the comfort levels within a house. This is because there is a... with resultant discomfort and extra heating costs. Today, in South Africa, most modern homesareof singlestorey con- struction with aconcrete floor slab in direct contact with theground which once again makes its full contribution to the comfort and structural...

  3. Investigation of floor Nusselt number in floor heating system for insulated ceiling conditions

    International Nuclear Information System (INIS)

    Karadag, Refet; Teke, Ismail

    2007-01-01

    In this study, in a floor heated room, natural convection heat transfer over the floor is analysed numerically for different thermal conditions. An equation relevant to Nusselt number over the floor has been obtained by using the numerical data. Different equations are given in the literature. They consider the effect of floor Rayleigh number while neglecting the effect of wall and ceiling thermal conditions. Numerical data obtained in this study show that the Nusselt number over the floor depends on not only the floor Rayleigh number but also the wall Rayleigh number (for insulated ceiling conditions). The equations given in the literature are different from each other due to their not considering the effect of wall and ceiling Rayleigh numbers. This difference between the equations may be eliminated by obtaining an equation containing the effect of floor, wall and ceiling Rayleigh numbers. In this new approach, an equation relevant to the floor Nusselt number that depends on the floor and wall Rayleigh numbers has been obtained in the floor heating system for insulated ceiling conditions. The equation obtained in this study has been compared with the equations given in the literature. It has been seen that the equation obtained in this study matches the numerical values under more extensive thermal conditions than the equations given in the literature. The maximum deviation for the equations given in the literature is 35%, but in the current study, the maximum deviation has been found to be 10%. As a result, it is more convenient to use the equation found in the new approach as a function of Rayleigh number over the floor and wall for insulated ceiling conditions

  4. CURB-BASED STREET FLOOR EXTRACTION FROM MOBILE TERRESTRIAL LIDAR POINT CLOUD

    Directory of Open Access Journals (Sweden)

    S. Ibrahim

    2012-07-01

    Full Text Available Mobile terrestrial laser scanners (MTLS produce huge 3D point clouds describing the terrestrial surface, from which objects like different street furniture can be generated. Extraction and modelling of the street curb and the street floor from MTLS point clouds is important for many applications such as right-of-way asset inventory, road maintenance and city planning. The proposed pipeline for the curb and street floor extraction consists of a sequence of five steps: organizing the 3D point cloud and nearest neighbour search; 3D density-based segmentation to segment the ground; morphological analysis to refine out the ground segment; derivative of Gaussian filtering to detect the curb; solving the travelling salesman problem to form a closed polygon of the curb and point-inpolygon test to extract the street floor. Two mobile laser scanning datasets of different scenes are tested with the proposed pipeline. The results of the extracted curb and street floor are evaluated based on a truth data. The obtained detection rates for the extracted street floor for the datasets are 95% and 96.53%. This study presents a novel approach to the detection and extraction of the road curb and the street floor from unorganized 3D point clouds captured by MTLS. It utilizes only the 3D coordinates of the point cloud.

  5. Simulation of Field Dependence of Critical Current Densities of Bulk High Tc Superconducting Materials regarding Thermally Activated Flux Motion

    Science.gov (United States)

    Santosh, M.; Naik, S. Pavan Kumar; Koblischka, M. R.

    2017-07-01

    In the upcoming generation, bulk high temperature superconductors (HTS) will play a crucial and a promising role in numerous industrial applications ranging from Maglev trains to magnetic resonance imaging, etc. Especially, the bulk HTS as permanent magnets are suitable due to the fact that they can trap magnetic fields being several orders of magnitude higher than those of the best hard ferromagnets. The bulk HTS LREBa2Cu3O7-δ (LREBCO or LRE-123, LRE: Y, Gd, etc.,) materials could obtain very powerful compact superconducting super-magnets, which can be operated at the cheaper liquid nitrogen temperature or below due to higher critical temperatures (i.e., ∼90 K). As a result, the new advanced technology can be utilized in a more attractive manner for a variety of technological and medical applications which have the capacity to revolutionize the field. An understanding of the magnetic field dependence of the critical current density (J c(H)) is important to develop better adapted materials. To achieve this goal, a variety of Jc (H) behaviours of bulk LREBCO samples were modelled regarding thermally activated flux motion. In essence, the Jc (H) curves follows a certain criterion where an exponential model is applied. However, to fit the complete Jc (H) curve of the LRE-123 samples an unique model is necessary to explain the behavior at low and high fields. The modelling of the various superconducting materials could be understood in terms of the pinning mechanisms.

  6. Effect of pelvic floor rehabilitation technique in preventing the postpartum pelvic floor dysfunction

    Directory of Open Access Journals (Sweden)

    Shi-Qiong Li

    2017-04-01

    Full Text Available Objective: To explore the effect of pelvic floor rehabilitation technique in preventing the postpartum pelvic floor dysfunction and on the sexual life quality. Methods: A total of 286 puerpera with pelvic floor dysfunction who were admitted in our hospital from May, 2014 to May, 2015 42 d after delivery were included in the study, and randomized into the treatment group and the control group with 143 cases in each group. After guidance, the puerpera in the control group were given pelvic floor muscle training by themselves at home. On this basis, the puerpera in the treatment group were treated by the pelvic floor rehabilitation apparatus. The puerpera in the two groups were treated for 4 weeks. The pelvic floor function before treatment, 6 months and 1 year after delivery was detected. The color Doppler ultrasound apparatus was used to detect BSD, PUVA, UVJ-M, and BND 3 months after delivery. Results: BND, PUVA-R, PUVA-S, and UVJ-M 3 months after delivery in the treatment groups were significantly lower than those in the control group, while BSD-S was significantly higher than that in the control group. The improvement of type I and II muscle fiber fatigue (%, POP-Q degree, AP indication point (cm, and vaginal dynamic pressure (cmH2O was significantly superior to that in the control group. The comparison of pelvic floor muscle strength classification before treatment between the two groups was not statistically significant. After treatment, the pelvic floor muscle in the two groups was significantly strengthened, and the proportion of V grade patients was significantly increased when compared with before treatment. Conclusions: The postpartum early pelvic floor rehabilitation technique can effectively enhance the pelvic floor function, and prevent the postpartum pelvic floor dysfunction, with an accurate efficacy; therefore, it deserves to be widely recommended in the clinic.

  7. Decontamination of floor surfaces

    International Nuclear Information System (INIS)

    Smirous, F.

    1983-01-01

    Requirements are presented put on the surfaces of floors of radiochemical workplaces. The mechanism is described of retaining the contaminant in the surface of the flooring, ways of reducing the hazards of floor surface contamination, decontamination techniques and used decontamination agents. (J.P.)

  8. 75 FR 34573 - Bulk Solid Hazardous Materials: Harmonization With the International Maritime Solid Bulk Cargoes...

    Science.gov (United States)

    2010-06-17

    ... reduced iron (DRI) as briquettes molded at a temperature of 650 [deg]C or higher that have a density of 5... temperature of 650 [deg]C or higher or had a density of 5.0 g/cm[sup3] or greater. In this proposed rule, we... bulk materials of Hazard Classes 4 through 9. c. One comment recommended that a DCM be required for...

  9. Theory of bulk-surface coupling in topological insulator films

    Science.gov (United States)

    Saha, Kush; Garate, Ion

    2014-12-01

    We present a quantitative microscopic theory of the disorder- and phonon-induced coupling between surface and bulk states in doped topological insulator films. We find a simple mathematical structure for the surface-to-bulk scattering matrix elements and confirm the importance of bulk-surface coupling in transport and photoemission experiments, assessing its dependence on temperature, carrier density, film thickness, and particle-hole asymmetry.

  10. Floor-fractured craters on Ceres and implications for interior processes

    Science.gov (United States)

    Buczkowski, Debra; Schenk, Paul M.; Scully, Jennifer E. C.; Park, Ryan; Preusker, Frank; Raymond, Carol; Russell, Christopher T.

    2016-10-01

    Several of the impact craters on Ceres have patterns of fractures on their floors. These fractures appear similar to those found within a class of lunar craters referred to as Floor-Fractured Craters (FFCs) [Schultz, 1976].Lunar FFCs are characterized by anomalously shallow floors cut by radial, concentric, and/or polygonal fractures, and have been classified into crater classes, Types 1 through 6, based on their morphometric properties [Schultz, 1976; Jozwiak et al, 2012, 2015]. Models for their formation have included both floor uplift due to magmatic intrusion below the crater or floor shallowing due to viscous relaxation. However, the observation that the depth versus diameter (d/D) relationship of the FFCs is distinctly shallower than the same association for other lunar craters supports the hypotheses that the floor fractures form due to shallow magmatic intrusion under the crater [Jozwiak et al, 2012, 2015].FFCs have also been identified on Mars [Bamberg et al., 2014]. Martian FFCs exhibit morphological characteristics similar to the lunar FFCs, and analyses suggest that the Martian FCCs also formed due to volcanic activity, although heavily influenced by interactions with groundwater and/or ice.We have cataloged the Ceres FFCs according to the classification scheme designed for the Moon. Large (>50 km) Ceres FFCs are most consistent with Type 1 lunar FFCs, having deep floors, central peaks, wall terraces, and radial and/or concentric fractures. Smaller craters on Ceres are more consistent with Type 4 lunar FFCs, having less-pronounced floor fractures and a v-shaped moats separating the wall scarp from the crater interior.An analysis of the d/D ratio for Ceres craters shows that, like lunar FFCs, the Ceres FFCs are anomalously shallow. This suggests that the fractures on the floor of Ceres FFCs may be due the intrusion of a low-density material below the craters that is uplifting their floors. While on the Moon and Mars the intrusive material is hypothesized

  11. Error floor behavior study of LDPC codes for concatenated codes design

    Science.gov (United States)

    Chen, Weigang; Yin, Liuguo; Lu, Jianhua

    2007-11-01

    Error floor behavior of low-density parity-check (LDPC) codes using quantized decoding algorithms is statistically studied with experimental results on a hardware evaluation platform. The results present the distribution of the residual errors after decoding failure and reveal that the number of residual error bits in a codeword is usually very small using quantized sum-product (SP) algorithm. Therefore, LDPC code may serve as the inner code in a concatenated coding system with a high code rate outer code and thus an ultra low error floor can be achieved. This conclusion is also verified by the experimental results.

  12. Compilation of PRF Canyon Floor Pan Sample Analysis Results

    Energy Technology Data Exchange (ETDEWEB)

    Pool, Karl N. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Minette, Michael J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wahl, Jon H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Greenwood, Lawrence R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Coffey, Deborah S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); McNamara, Bruce K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Bryan, Samuel A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Scheele, Randall D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Delegard, Calvin H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sinkov, Sergey I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Soderquist, Chuck Z. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Fiskum, Sandra K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Brown, Garrett N. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Clark, Richard A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-06-30

    On September 28, 2015, debris collected from the PRF (236-Z) canyon floor, Pan J, was observed to exhibit chemical reaction. The material had been transferred from the floor pan to a collection tray inside the canyon the previous Friday. Work in the canyon was stopped to allow Industrial Hygiene to perform monitoring of the material reaction. Canyon floor debris that had been sealed out was sequestered at the facility, a recovery plan was developed, and drum inspections were initiated to verify no additional reactions had occurred. On October 13, in-process drums containing other Pan J material were inspected and showed some indication of chemical reaction, limited to discoloration and degradation of inner plastic bags. All Pan J material was sealed back into the canyon and returned to collection trays. Based on the high airborne levels in the canyon during physical debris removal, ETGS (Encapsulation Technology Glycerin Solution) was used as a fogging/lock-down agent. On October 15, subject matter experts confirmed a reaction had occurred between nitrates (both Plutonium Nitrate and Aluminum Nitrate Nonahydrate (ANN) are present) in the Pan J material and the ETGS fixative used to lower airborne radioactivity levels during debris removal. Management stopped the use of fogging/lock-down agents containing glycerin on bulk materials, declared a Management Concern, and initiated the Potential Inadequacy in the Safety Analysis determination process. Additional drum inspections and laboratory analysis of both reacted and unreacted material are planned. This report compiles the results of many different sample analyses conducted by the Pacific Northwest National Laboratory on samples collected from the Plutonium Reclamation Facility (PRF) floor pans by the CH2MHill’s Plateau Remediation Company (CHPRC). Revision 1 added Appendix G that reports the results of the Gas Generation Rate and methodology. The scope of analyses requested by CHPRC includes the determination of

  13. Quantum information aspects on bulk and nano interacting Fermi system: A spin-space density matrix approach

    Energy Technology Data Exchange (ETDEWEB)

    Afzali, R., E-mail: afzali@kntu.ac.ir [Department of Physics, K. N. Toosi University of Technology, Tehran, 15418 (Iran, Islamic Republic of); Ebrahimian, N., E-mail: n.ebrahimian@shahed.ac.ir [Department of Physics, Faculty of Basic Sciences, Shahed University, Tehran, 18155-159 (Iran, Islamic Republic of); Eghbalifar, B., E-mail: b.eghbali2011@yahoo.com [Department of Agricultural Management, Marvdasht Branch, Azad University, Marvdasht (Iran, Islamic Republic of)

    2016-10-07

    Highlights: • In contrast to a s-wave superconductor, the quantum correlation of the d-wave superconductor is sensitive to the change of the gap magnitude. • Quantum discord of the d-wave superconductor oscillates. • Quantum discord becomes zero at a characteristic length of the d-wave superconductor. • Quantum correlation strongly depends on the length of grain. Length of the superconductor lower, the quantum correlation length higher. • Quantum tripartite entanglement for a nano-scale d-wave superconductor is better than for a bulk d-wave superconductor. - Abstract: By approximating the energy gap, entering nano-size effect via gap fluctuation and calculating the Green's functions and the space-spin density matrix, the dependence of quantum correlation (entanglement, discord and tripartite entanglement) on the relative distance of two electron spins forming Cooper pairs, the energy gap and the length of bulk and nano interacting Fermi system (a nodal d-wave superconductor) is determined. In contrast to a s-wave superconductor, quantum correlation of the system is sensitive to the change of the gap magnitude and strongly depends on the length of the grain. Also, quantum discord oscillates. Furthermore, the entanglement length and the correlation length are investigated. Discord becomes zero at a characteristic length of the d-wave superconductor.

  14. Effect of initial bulk density on high-solids anaerobic digestion of MSW: General mechanism.

    Science.gov (United States)

    Caicedo, Luis M; Wang, Hongtao; Lu, Wenjing; De Clercq, Djavan; Liu, Yanjun; Xu, Sai; Ni, Zhe

    2017-06-01

    Initial bulk density (IBD) is an important variable in anaerobic digestion since it defines and optimizes the treatment capacity of a system. This study reveals the mechanism on how IBD might affect anaerobic digestion of waste. Four different IBD values: D 1 (500-700kgm -3 ), D 2 (900-1000kgm -3 ), D 3 (1100-1200kgm -3 ) and D 4 (1200-1400kgm -3 ) were set and tested over a period of 90days in simulated landfill reactors. The main variables affected by the IBD are the methane generation, saturation degree, extraction of organic matter, and the total population of methanogens. The study identified that IBD >1000kgm -3 may have significant effect on methane generation, either prolonging the lag time or completely inhibiting the process. This study provides a new understanding of the anaerobic digestion process in saturated high-solids systems. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Analysis of Physical and Mechanical Properties of Marble Particles Floor-Tile Composite

    International Nuclear Information System (INIS)

    Parikin; Arslan, A.; Ismoyo, A.H.; Jodi, H.E.; Nurhasanah, S.

    2002-01-01

    Two criteria that very predictable to quality products of marble particles composite floor-tile are physical and mechanical properties. Simple manufacturing was conducted from powdering refuges of marble to molding and drying the specimens at ambient atmosphere. The characterization, to observe; density, crystal structure, microstructure, hardness and compressive/bending strength of the material, was performed in Serpong and IPB-Bogor. The analysis shows that polymeric crystallization was occurred by HEXA and the density and the hardness generally rise up with the improvements in mesh and composition of marble particles. But it is not always followed by the real improvements of compressive and bending strength, which related to the material stiffness. The curves figured that these two strengths give the maximum values at 60% composition of marble particles. It can be concluded that density and hardness are dependent on mesh and composition, whereas the stiffness (modulus) is only correlation with composition of particulate. The theoretical modulus of marble particles composite floor-tile has been evaluated at about 56.19 GPa. (author)

  16. Magnetic levitation force between a superconducting bulk magnet and a permanent magnet

    International Nuclear Information System (INIS)

    Wang, J J; He, C Y; Meng, L F; Li, C; Han, R S; Gao, Z X

    2003-01-01

    The current density J(ρ, z) in a disc-shaped superconducting bulk magnet and the magnetic levitation force F SBM z exerted on the superconducting bulk magnet by a cylindrical permanent magnet are calculated from first principles. The effect of the superconducting parameters of the superconducting bulk is taken into account by assuming the voltage-current law E = E c (J/J c ) n and the material law B = μ 0 H. The magnetic levitation force F SBM z is dominated by the remnant current density J' 2 (ρ, z), which is induced by switching off the applied magnetizing field. High critical current density and flux creep exponent may increase the magnetic levitation force F SBM z . Large volume and high aspect ratio of the superconducting bulk can further enhance the magnetic levitation force F SBM z

  17. Flooring-systems and their interaction with usage of the floor

    DEFF Research Database (Denmark)

    Pedersen, Lars; Frier, Christian; Andersen, Lars Vabbersgaard

    2017-01-01

    Some flooring-system designs might be sensitive to their vibrational performance, as there might be the risk that serviceability-limit-state problems may be encountered. For evaluating the vibrational performance of the flooring-system at the design stage, decisions need to be made by the enginee...

  18. Evaluation of flooring produced from small diameters logs of Eucalyptus sp. clones

    Directory of Open Access Journals (Sweden)

    José Reinaldo Moreira da Silva

    2010-12-01

    Full Text Available This study evaluated two Eucalyptus clones, MN 249 and MN 89, for the flooring production using small diameters logs. It was considered the wood physical properties - NBR 7190/97 (ABNT, 1997 and simulation of the product in service (ASTM D 2394/83 with two thicknesses, 8 and 14 mm. The basic density of the clone 89 NM was the highest one (0,615 g/cm3. The contractions were more pronounced in clone NM 249, however, the anisotropy coefficient of this clone was small. In the simulation tests, the floor produced by clone MN 249 presented the lowest deformation rate. The floor of 8 mm, in addition to the differences between clones, there was significant interaction between the positions for the indentation test caused by loads applied in small areas. The deformations obtained for the floor with 14 mm thickness, produced with the MN clone 89, were higher than those found in the literature for the indentation load applied on a small area test. The clone MN 249 presented the best results in both thicknesses.

  19. Supporting shop floor intelligence

    DEFF Research Database (Denmark)

    Carstensen, Peter; Schmidt, Kjeld; Wiil, Uffe Kock

    1999-01-01

    Many manufacturing enterprises are now trying to introduce various forms of flexible work organizations on the shop floor. However, existing computer-based production planning and control systems pose severe obstacles for autonomous working groups and other kinds of shop floor control to become r......-to-day production planning by supporting intelligent and responsible workers in their situated coordination activities on the shop floor....

  20. Floor-Fractured Craters on Ceres and Implications for Internal Composition and Processes

    Science.gov (United States)

    Buczkowski, D.; Schenk, P.; Scully, J. E. C.; Park, R. S.; Preusker, F.; Raymond, C. A.; Russell, C. T.

    2016-12-01

    Several of the impact craters on Ceres have patterns of fractures on their floors. These fractures appear similar to those found within a class of lunar craters referred to as Floor-Fractured Craters (FFCs) [1]. Lunar FFCs are characterized by anomalously shallow floors cut by radial, concentric, and/or polygonal fractures, and have been classified into crater classes, Types 1 through 6, based on their morphometric properties [1,2]. Models for their formation have included both floor uplift due to magmatic intrusion below the crater or floor shallowing due to viscous relaxation. However, the observation that the depth versus diameter (d/D) relationship of the FFCs is distinctly shallower than the same association for other lunar craters supports the hypotheses that the floor fractures form due to shallow magmatic intrusion under the crater [2]. We have cataloged the Ceres FFCs according to the classification scheme designed for the Moon. Large (>50 km) Ceres FFCs are most consistent with Type 1 lunar FFCs, having deep floors, central peaks, wall terraces, and radial and/or concentric fractures. Smaller craters on Ceres are more consistent with Type 4 lunar FFCs, having less-pronounced floor fractures and v-shaped moats separating the wall scarp from the crater interior. An analysis of the d/D ratio for Ceres craters shows that, like lunar FFCs, the Ceres FFCs are anomalously shallow. This suggests that the fractures on the floor of Ceres FFCs may be due the intrusion of a low-density material below the craters that is uplifting their floors. While on the Moon the intrusive material is hypothesized to be silicate magma, this is unlikely for Ceres. However, a cryovolcanic extrusive edifice has been identified on Ceres [3], suggesting that cryomagmatic intrusions could be responsible for the formation of the Ceres FFCs. References: [1] Schultz P. (1976) Moon, 15, 241-273 [2] Jozwiak L.M. et al (2015) JGR 117, doi: 10.1029/2012JE004134 [3] Ruesch O. et al (2016

  1. Magnetic levitation force between a superconducting bulk magnet and a permanent magnet

    Energy Technology Data Exchange (ETDEWEB)

    Wang, J J; He, C Y; Meng, L F; Li, C; Han, R S; Gao, Z X [Department of Physics, Key Laboratory for Artificial Microstructure and Mesoscopic Physics, Peking University, Beijing 100871 (China)

    2003-04-01

    The current density J({rho}, z) in a disc-shaped superconducting bulk magnet and the magnetic levitation force F{sup SBM}{sub z} exerted on the superconducting bulk magnet by a cylindrical permanent magnet are calculated from first principles. The effect of the superconducting parameters of the superconducting bulk is taken into account by assuming the voltage-current law E = E{sub c}(J/J{sub c}){sup n} and the material law B = {mu}{sub 0}H. The magnetic levitation force F{sup SBM}{sub z} is dominated by the remnant current density J'{sub 2}({rho}, z), which is induced by switching off the applied magnetizing field. High critical current density and flux creep exponent may increase the magnetic levitation force F{sup SBM}{sub z}. Large volume and high aspect ratio of the superconducting bulk can further enhance the magnetic levitation force F{sup SBM}{sub z}.

  2. Superior critical current density obtained in MgB_2 bulks via employing carbon-coated boron and minor Cu addition

    International Nuclear Information System (INIS)

    Peng, Junming; Liu, Yongchang; Ma, Zongqing; Shahriar Al Hossain, M.; Xin, Ying; Jin, Jianxun

    2016-01-01

    Highlights: • Usage of carbon-coated boron leads to high level of homogeneous carbon doping. • Cu addition improves MgB_2 grain connectivity, leading to higher J_c at low fields. • Cu addition reduces MgO impurity, also contributing to the improvement of J_c. - Abstract: High performance Cu doped MgB_2 bulks were prepared by an in-situ method with carbon-coated amorphous boron as precursor. It was found that the usage of carbon-coated boron in present work leads to the formation of uniformly refined MgB_2 grains, as well as a high level of homogeneous carbon doping in the MgB_2 samples, which significantly enhance the J_c in both Cu doped and undoped bulks compared to MgB_2 bulks with normal amorphous boron precursor. Moreover, minor Cu can service as activator, and thus facilitates the growth of MgB_2 grains and improves crystallinity and grain connectivity, which can bring about the excellent critical current density (J_c) at self fields and low fields (the best values are 7 × 10"5 A/cm"2 at self fields, and 1 × 10"5 A/cm"2 at 2 T, 20 K, respectively). Simultaneously, minor Cu addition can reduce the amount of MgO impurity significantly, also contributing to the improvement of J_c at low fields. Our work suggests that Cu-activated sintering combined with employment of carbon-coated amorphous boron as precursor could be a promising technique to produce practical MgB_2 bulks or wires with excellent J_c on an industrial scale.

  3. Simultaneous bulk density and soil moisture determination by attenuation of 137 Cs and 241 Am

    International Nuclear Information System (INIS)

    Barros Ferraz, E.S. de.

    1974-01-01

    The method of simultaneous bulk density and soil moisture determination by attenuation of 241 Am and 137 Cs gamma-radiation is introduced and studied with detail. Theoretical considerations are made about the attenuation process in the absorbers, the form of solving the problem of two unknowns, the sensitivity of the method the influences of the resolution time of the electronic counting equipment, and of the Compton scattering in the sample. From the methodological point of view studies are made about the influence of the geometry, adjustment of counting system, choice of radiation sources, attenuation coefficient and the manner of obtaining reliable measurements. Data obtained are analysed, discussed and compared with those found in the literature. Finally the author presents some applications of the method, its use in soil-water movement studies, in soil profile compaction studies, and specially in swelling soils. (author)

  4. Influence of soft ferromagnetic sections on the magnetic flux density profile of a large grain, bulk Y–Ba–Cu–O superconductor

    International Nuclear Information System (INIS)

    Philippe, M P; Wéra, L; Fagnard, J-F; Vanderheyden, B; Vanderbemden, P; Ainslie, M D; Dennis, A R; Shi, Y-H; Cardwell, D A

    2015-01-01

    Bulk, high temperature superconductors have significant potential for use as powerful permanent magnets in a variety of practical applications due to their ability to trap record magnetic fields. In this paper, soft ferromagnetic sections are combined with a bulk, large grain Y–Ba–Cu–O high temperature superconductor to form superconductor/ferromagnet hybrid structures. We study how the ferromagnetic sections influence the shape of the profile of the trapped magnetic induction at the surface of each structure and report the surface magnetic flux density measured by Hall probe mapping. These configurations have been modelled using a 2D axisymmetric finite element method based on the H-formulation and the results show excellent qualitative and quantitative agreement with the experimental measurements. The model has also been used to study the magnetic flux distribution and predict the behaviour for other constitutive laws and geometries. The results show that the ferromagnetic material acts as a magnetic shield, but the flux density and its gradient are enhanced on the face opposite to the ferromagnet. The thickness and saturation magnetization of the ferromagnetic material are important and a characteristic ferromagnet thickness d* is derived: below d*, saturation of the ferromagnet occurs, and above d*, a weak thickness-dependence is observed. The influence of the ferromagnet is observed even if its saturation magnetization is lower than the trapped flux density of the superconductor. Conversely, thin ferromagnetic discs can be driven to full saturation even though the outer magnetic field is much smaller than their saturation magnetization. (paper)

  5. 17 CFR 3.11 - Registration of floor brokers and floor traders.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 1 2010-04-01 2010-04-01 false Registration of floor brokers and floor traders. 3.11 Section 3.11 Commodity and Securities Exchanges COMMODITY FUTURES TRADING... a contract market or registered as a derivatives transaction execution facility by the Commission...

  6. Influence of grain boundary connectivity on the trapped magnetic flux of multi-seeded bulk superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Z., E-mail: zgdeng@gmail.com [Laboratory of Applied Physics, Department of Marine Electronics and Mechanical Engineering, Tokyo University of Marine Science and Technology, Tokyo 135-8533 (Japan); Miki, M.; Felder, B.; Tsuzuki, K.; Shinohara, N.; Hara, S.; Uetake, T.; Izumi, M. [Laboratory of Applied Physics, Department of Marine Electronics and Mechanical Engineering, Tokyo University of Marine Science and Technology, Tokyo 135-8533 (Japan)

    2011-09-15

    Four different performance multi-seeded YBCO bulks as representatives. A coupling ratio to reflect the coupling quality of GBs inside multi-seeded bulks. An averaged trapped magnetic flux density parameter was introduced. The top-seeded melt-growth process with multi-seeding technique provides a promising way to fabricate large-sized bulk superconductors in an economical way. To understand the essential characteristics of the multi-seeded bulks, the paper reports the influence of the grain boundary (GB) coupling or connectivity on the total trapped magnetic flux. The coupling ratio, the lowest trapped flux density in the GB area to the averaged top value of the two neighboring peak trapped fields, is introduced to reflect the coupling quality of GBs inside a multi-seeded bulk. By the trapped flux density measurement of four different performance multi-seeded YBCO bulk samples as representatives, it was found that the GB coupling plays an important role for the improvement of the total trapped magnetic flux; moreover, somewhat more significant than the widely used parameter of the peak trapped fields to evaluate the physical performance of bulk samples. This characteristic is different with the case of the well-grown single-grain bulks.

  7. Floor cooler for floor trough of a nuclear reactor

    International Nuclear Information System (INIS)

    Friedrich, H.J.

    1985-01-01

    Cooling pipes are situated below the floor trough of a BWR, which are connected to the annular distribution or collection pipes. The distribution and collection pipes are connected by parallel hairpin pipes with involute shape to the centre of the floor trough. These hairpin pipes are situated in a lower plane than the annular distribution pipe to the centre and in a higher plane from the centre to the outer annular collector pipe. (orig./HP) [de

  8. 129Xe NMR spectroscopy in microporous solids: The effect of bulk properties

    International Nuclear Information System (INIS)

    Ripmeester, John A.; Ratcliffe, Christopher I.

    1993-01-01

    In this contribution we point out a number of factors related to the bulk properties of microporous solids which must be taken into account in order first of all to obtain meaningful 129 Xe NMR spectral data, and secondly to interpret the data properly. This sensitivity to bulk properties is especially important for microporous solids where there is little or no barrier to xenon passage from inside the particle to the interparticle space. We examine the effect of particle size, powder bulk density and particle anisotropy, and also the effect of low thermal conductivity of low density powders

  9. [Functional aspects of pelvic floor surgery].

    Science.gov (United States)

    Wagenlehner, F M E; Gunnemann, A; Liedl, B; Weidner, W

    2009-11-01

    Pelvic floor dysfunctions are frequently seen in females. The human pelvic floor is a complex structure and heavily stressed throughout female life. Recent findings in the functional anatomy of the pelvic floor have led to a much better understand-ing, on the basis of which enormous improvements in the therapeutic options have arisen. The pelvic floor activity is regulated by three main muscular forces that are responsible for vaginal tension and suspension of the pelvic floor -organs, bladder and rectum. For different reasons laxity in the vagina or its supporting ligaments as a result of altered connective tissue can distort this functional anatomy. A variety of symptoms can derive from these pelvic floor dysfunctions, such as urinary urge and stress incontinence, abnormal bladder emptying, faecal incontinence, obstructive bowel disease syndrome and pelvic pain. Pelvic floor reconstruction is nowadays driven by the concept that in the case of pelvic floor symptoms restoration of the anatomy will translate into restoration of the physiology and ultimately improve the patients' symptoms. The exact surgical reconstruction of the anatomy is there-fore almost exclusively focused on the restoration of the lax pelvic floor ligaments. An exact identification of the anatomic lesions preoperatively is eminently necessary, to allow for an exact anatomic reconstruction with respect to the muscular forces of the pelvic floor. Georg Thieme Verlag Stuttgart * New York.

  10. Pelvic floor physical therapy in urogynecologic disorders.

    Science.gov (United States)

    Kotarinos, Rhonda K

    2003-08-01

    Physical therapists are uniquely qualified to treat pelvic floor dysfunction with conservative management techniques. Techniques associated with incontinence and support functions of the pelvic floor include bladder training and pelvic floor rehabilitation: pelvic floor exercises, biofeedback therapy, and pelvic floor electrical stimulation. Pain associated with mechanical pelvic floor dysfunction can be treated by physical therapists utilizing various manual techniques and modalities. Research documents that conservative management is effective in treating many conditions associated with pelvic floor dysfunction. Research should be conducted to determine if addressing diastasis recti and contracture of the pelvic floor musculature should be a component of the standard physical therapy protocol.

  11. School Flooring Factors

    Science.gov (United States)

    McGrath, John

    2012-01-01

    With all of the hype that green building is receiving throughout the school facility-management industry, it's easy to overlook some elements that may not be right in front of a building manager's nose. It is helpful to examine the role floor covering plays in a green building project. Flooring is one of the most significant and important systems…

  12. Bulk delivery of explosives offers positive advantages

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-09-01

    The bulk delivery of precisely-formulated explosives directly to the shothole is a safe, secure and cost effective way of bringing rock to the quarry floor. This article describes several of the latest generation of Anfo trucks. The typical Anfo truck carries ammonium nitrate and fuel oil in bulk, together with several other mix constituents, including an emulsifying agent. These are designed to form the basis of a range of emulsion-type explosives. In effect, these are water in oil emulsions where the water phase consists of droplets of a saturated solution of the oxidizing material suspended in oil. The formulations may be further tailored to the shothole requirements by the addition of oils or waxes, which can alter the viscosity of the explosive. The precise and programmable controls which determine the exact quantities of materials delivered to the mixer mean that the explosive mixtures can be tailored exactly to the requirements of the blasting operation, be it the amount of rock to be dislodged, the geological conditions, or the state of the shothole - either wet or dry. 4 systems are described in detail. 3 figs.

  13. Critical current characteristics and history dependence in superconducting SmFeAsOF bulk

    International Nuclear Information System (INIS)

    Ni, B; Ge, J; Kiuchi, M; Otabe, E S; Gao, Z; Wang, L; Qi, Y; Zhang, X; Ma, Y

    2010-01-01

    The superconducting SmFeAsO 1-x F x (x=0.2) polycrystalline bulks were prepared by the powder-in-tube (PIT) method. The magnetic field and temperature dependences of critical current densities in the samples were investigated by resistive and ac inductive (Campbell's) methods. It was found that a fairly large shielding current density over 10 9 A/m 2 , which is considered to correspond to the local critical current density, flows locally with the perimeter size similar to the average grain size of the bulk samples, while an extremely low transport current density of about 10 5 A/m 2 corresponding to the global critical current density flows through the whole sample. Furthermore, a unique history dependence of global critical current density was observed, i.e., it shows a smaller value in the increasing-field process than that in the decreasing-field process. The history dependence of global critical current characteristic in our case can be ascribed to the existence of the weak-link property between the grains in SmFeAsO 1-x F x bulk.

  14. Price floors for emissions trading

    International Nuclear Information System (INIS)

    Wood, Peter John; Jotzo, Frank

    2011-01-01

    Price floors in greenhouse gas emissions trading schemes can guarantee minimum abatement efforts if prices are lower than expected, and they can help manage cost uncertainty, possibly as complements to price ceilings. Provisions for price floors are found in several recent legislative proposals for emissions trading. Implementation however has potential pitfalls. Possible mechanisms are government commitments to buy back permits, a reserve price at auction, or an extra fee or tax on acquittal of emissions permits. Our analysis of these alternatives shows that the fee approach has budgetary advantages and is more compatible with international permit trading than the alternatives. It can also be used to implement more general hybrid approaches to emissions pricing. - Research highlights: → Price floors for emissions trading schemes guarantee a minimum carbon price. → Price floors mean that emissions can be less than specified by the ETS cap. → We examine how price floors can relate to different policy objectives. → We compare different mechanisms for implementing a price floor. → We find that a mechanism where there is an extra tax or fee has advantages.

  15. 46 CFR 151.03-21 - Filling density.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Filling density. 151.03-21 Section 151.03-21 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES BARGES CARRYING BULK LIQUID HAZARDOUS MATERIAL CARGOES Definitions § 151.03-21 Filling density. The ratio, expressed as...

  16. Floor heating systems

    Energy Technology Data Exchange (ETDEWEB)

    Radtke, U

    1984-02-01

    The question of whether PPC- and VPE-floor heating pipes can endure damage when incompletely imbedded in the floor finish is investigated in an experimental setup. An expansion of the pipe, caused by a temperature increase from 20/sup 0/C to 50/sup 0/C was measured and considered too small to deduce the degree of danger from the damage.

  17. The role of intramolecular crosslinking in the radiolysis of bulk crystallized high density polyethylene

    International Nuclear Information System (INIS)

    Lyons, B.J.

    1986-01-01

    Intramolecular crosslinks have been suggested to occur in bulk crystallized, irradiated, high density polyethylene (HDPE) and to account for the low rates of gel formation, especially those of previously annealed samples when compared with that manifested by the same resin when previously quenched from the melt. Such crosslinks do not contribute to the development of gel and contribute to only a limited extent to the elastic properties above the crystalline melting point when compared with intermolecular crosslinks, but, if the mesh size of the intra- and inter-molecular networks are comparable, are fully reflected in the rupture elongation. The rupture elongations of a wide range of HDPE resins, for a given sol fraction or elastic modulus, are found to be at least as high as and often higher than those of low (LDPE) or linear low (LLDPE) polyethylene resins, indicating that intramolecular crosslinking of this type does not occur to a significantly greater extent in these higher crystallinity resins. Other factors more likely to account for the reduced rates of inter alia gel formation in some HDPE resins are discussed. (author)

  18. Anisotropic cosmological models with bulk viscosity and particle ...

    Indian Academy of Sciences (India)

    4.1.3 Ideal gas. In the case of an ideal gas. = 0 and pc = 0. Then eq. (2) becomes. ˙η + 3ηH = 0. (69). Equation (69), on integration gives η = η1t. −3/n,. (70) where η1 is an integrating constant. Equation (69) is the expression for particle creation density. This model has only bulk viscosity and bulk viscous stress is obtained as.

  19. Magnetic properties and critical current density of bulk MgB2 polycrystalline with Bi-2212 addition

    International Nuclear Information System (INIS)

    Shen, T M; Li, G; Zhu, X T; Cheng, C H; Zhao, Y

    2005-01-01

    Bulk samples of MgB 2 were prepared with 0, 3, 5, and 10 wt% Bi 2 Sr 2 CaCu 2 O 8 (Bi-2212) particles, added using a simple solid-state reaction route in order to investigate the effect of inclusions of a material with higher T c than the superconducting matrix. The density, diamagnetic signal, and critical current density, J c , of the samples change significantly with the doping level. It is found that J c is significantly enhanced by the Bi-2212 addition. Microstructural analysis indicates that a small amount of Bi-2212 is decomposed into Cu 2 O and other impurity phases while a significant amount of unreacted Bi-2212 particles remains in MgB 2 matrix, and these act as effective pinning centres for vortices. The enhanced pinning force is mainly attributable to these highly dispersed inclusions inserted in the MgB 2 grains. Despite the effectiveness of the high-T c inclusions in increasing superconducting critical currents in our experiment, our results seem to demonstrate the superiority of attractive centres over repulsive ones. A pinning mechanism is proposed to account for the contribution of this type of pinning centre in MgB 2 superconductors. (rapid communication)

  20. Pelvic floor and sexual male dysfunction

    Directory of Open Access Journals (Sweden)

    Antonella Pischedda

    2013-04-01

    Full Text Available The pelvic floor is a complex multifunctional structure that corresponds to the genito- urinary-anal area and consists of muscle and connective tissue. It supports the urinary, fecal, sexual and reproductive functions and pelvic statics. The symptoms caused by pelvic floor dysfunction often affect the quality of life of those who are afflicted, worsening significantly more aspects of daily life. In fact, in addition to providing support to the pelvic organs, the deep floor muscles support urinary continence and intestinal emptying whereas the superficial floor muscles are involved in the mechanism of erection and ejaculation. So, conditions of muscle hypotonia or hypertonicity may affect the efficiency of the pelvic floor, altering both the functionality of the deep and superficial floor muscles. In this evolution of knowledge it is possible imagine how the rehabilitation techniques of pelvic floor muscles, if altered and able to support a voiding or evacuative or sexual dysfunction, may have a role in improving the health and the quality of life.

  1. Evaluation of the thermal comfort of ceramic floor tiles

    Directory of Open Access Journals (Sweden)

    Carmeane Effting

    2007-09-01

    Full Text Available In places where people are bare feet, the thermal sensation of cold or hot depends on the environmental conditions and material properties including its microstructure and crustiness surface. The uncomforting can be characterized by heated floor surfaces in external environments which are exposed to sun radiation (swimming polls areas or by cold floor surfaces in internal environments (bed rooms, path rooms. The property named thermal effusivity which defines the interface temperature when two semi-infinite solids are putted in perfect contact. The introduction of the crustiness surface on the ceramic tiles interferes in the contact temperature and also it can be a strategy to obtain ceramic tiles more comfortable. Materials with low conductivities and densities can be obtained by porous inclusion are due particularly to the processing conditions usually employed. However, the presence of pores generally involves low mechanical strength. This work has the objective to evaluate the thermal comfort of ceramics floor obtained by incorporation of refractory raw materials (residue of the polishing of the porcelanato in industrial atomized ceramic powder, through the thermal and mechanical properties. The theoretical and experimental results show that the porosity and crustiness surface increases; there is sensitive improvement in the comfort by contact.

  2. Polarization Dependent Bulk-sensitive Valence Band Photoemission Spectroscopy and Density Functional Theory Calculations: Part I. 3d Transition Metals

    Science.gov (United States)

    Ueda, Shigenori; Hamada, Ikutaro

    2017-12-01

    The X-ray polarization dependent valence band HAXPES spectra of 3d transition metals (TMs) of Ti-Zn were measured to investigate the orbital resolved electronic structures by utilizing that the fact the photoionization cross-section of the atomic orbitals strongly depends on the experimental geometry. We have calculated the HAXPES spectra, which correspond to the cross-section weighted densities of states (CSW-DOSs), where the DOSs were obtained by the density functional theory calculations, and we have determined the relative photoionization cross-sections of the 4s and 4p orbitals to the 3d orbital in the 3d TMs. The experimentally obtained bulk-sensitive 3d and 4s DOSs were good agreement with the calculated DOSs in Ti, V, Cr, and Cu. In contrast, the deviations between the experimental and calculated 3d DOSs for Mn, Fe, Co, Ni were found, suggesting that the electron correlation plays an important role in the electronic structures for these materials.

  3. Critical current density improvements in MgB2 superconducting bulk samples by K2CO3 additions  

    DEFF Research Database (Denmark)

    Grivel, J.-C.

    2018-01-01

    MgB2 bulk samples with potassium carbonate doping were made by means of reaction of elemental Mg and B powders mixed with various amounts of K2CO3. The Tc of the superconducting phase as well as its a-axis parameter were decreased as a result of carbon doping. Potassium escaped the samples during...... reaction. The critical current density of MgB2 was improved both in self field and under applied magnetic field for T ≤ 30 K, with optimum results for 1 mol% K2CO3 addition. The normalized flux pinning force (f(b)) shows that the flux pinning mechanism at low field is similar for all samples, following...

  4. Maxillary Sinus Floor Augmentation

    DEFF Research Database (Denmark)

    Starch-Jensen, Thomas; Jensen, Janek Dalsgaard

    2017-01-01

    , radiological and histomorphometric outcome as well as complications are presented after maxillary sinus floor augmentation applying the lateral window technique with a graft material, maxillary sinus membrane elevation without a graft material and osteotome-mediated sinus floor elevation with or without...

  5. The effect of sub-floor heating on house-dust-mite populations on floors and in furniture.

    Science.gov (United States)

    de Boer, Rob

    2003-01-01

    It is well known that dehydrating conditions for house dust mites can be created by simply raising the temperature, causing loss of body water and eventually death. Thus, it can be expected that conditions for dust mites are less favourable on floors supplied with sub-floor heating. This was examined in a study of 16 houses with sub-floor heating and 21 without. The pattern of changes in air humidity and temperature on the floors was investigated and compared to known data of the tolerance of dust mites. Also the resident mite populations were compared. Floors with sub-floor heating had, on average, fewer mites, but the difference with unheated floors was small. It was remarkable that mite numbers were also lower in upholstered furniture. Another important observation was that some houses with sub-floor heating had high mite numbers, indicating that this type of heating is compatible with a thriving mite population. Temperature and humidity conditions of heated floors may allow mites not only to survive, but also to remain active in winter. A moderate increase in temperature, a moderate decrease in (absolute) air humidity, or a combination of both, will suffice to keep the humidity all winter below the Critical Equilibrium Humidity, the level of air humidity that is critical for mite growth and reproduction, hence for allergen production. However, it is argued that measures to suppress allergen production by house dust mites are likely to be far more effective if taken in summer rather than in winter.

  6. Renormalization group approach to causal bulk viscous cosmological models

    International Nuclear Information System (INIS)

    Belinchon, J A; Harko, T; Mak, M K

    2002-01-01

    The renormalization group method is applied to the study of homogeneous and flat Friedmann-Robertson-Walker type universes, filled with a causal bulk viscous cosmological fluid. The starting point of the study is the consideration of the scaling properties of the gravitational field equations, the causal evolution equation of the bulk viscous pressure and the equations of state. The requirement of scale invariance imposes strong constraints on the temporal evolution of the bulk viscosity coefficient, temperature and relaxation time, thus leading to the possibility of obtaining the bulk viscosity coefficient-energy density dependence. For a cosmological model with bulk viscosity coefficient proportional to the Hubble parameter, we perform the analysis of the renormalization group flow around the scale-invariant fixed point, thereby obtaining the long-time behaviour of the scale factor

  7. Morphology and morphometry of the human sublingual glands in mouth floor enlargements of edentulous patients

    Directory of Open Access Journals (Sweden)

    Josiane Costa Rodrigues de SA

    2013-12-01

    Full Text Available Asymptomatic mouth floor enlargements may be observed in edentulous patients. These masses, which protrude from the mouth floor, may complicate the fitting of dentures and require surgery. Whether this "entity" may be considered an anatomical variation of the mouth floor or represent specific alterations in the sublingual gland is not known. Objective: The aim of this work is to investigate the morphological and morphometric aspects of the sublingual glands of edentulous patients with mouth floor enlargements and compare the glands of these patients with the sublingual glands of human cadavers. Material and Methods: Microscopic evaluation was performed on human sublingual glands from edentulous patients with mouth floor enlargements (n=20 and edentulous cadavers (n=20. The patients and cadavers were of similar ages. The data were compared using Mann-Whitney U, Fisher's exact and Student's t tests (p0.05. Only the variables "autolysis" and "congested blood vessels" presented statistical difference between groups (p=0.014; p=0.043. The morphometric study revealed that the volume densities of acini, ducts, stroma and adipose tissue were similar between the groups (p>0.05. CONCLUSION: The microscopic characteristics of the sublingual glands in mouth floor enlargements in edentulous patients correspond to characteristics associated with the normal aging process. The glands are not pathological and represent an age-related alteration that occurs with or without the presence of the mouth floor enlargements.

  8. Big bang nucleosynthesis constraints on bulk neutrinos

    International Nuclear Information System (INIS)

    Goh, H.S.; Mohapatra, R.N.

    2002-01-01

    We examine the constraints imposed by the requirement of successful nucleosynthesis on models with one large extra hidden space dimension and a single bulk neutrino residing in this dimension. We solve the Boltzmann kinetic equation for the thermal distribution of the Kaluza-Klein modes and evaluate their contribution to the energy density at the big bang nucleosynthesis epoch to constrain the size of the extra dimension R -1 ≡μ and the parameter sin 2 2θ which characterizes the mixing between the active and bulk neutrinos

  9. Linear Alkylbenzenesulfonates in indoor Floor Dust

    DEFF Research Database (Denmark)

    Madsen, Jørgen Øgaard; Wolkoff, Peder; Madsen, Jørgen Øgaard

    1999-01-01

    The amount of Linear Alkylbenzenesulfonates (LAS) in the particle fraction of floor dust sampled from 7 selected public buildings varied between 34 and 1500 microgram per gram dust, while the contents of the fibre fractions generally were higher with up to 3500 microgram LAS/g dust. The use...... of a cleaning agent with LAS resulted in an increase of the amount of LAS in the floor dust after floor wash relative to just before floor wash. However, the most important source of LAS in the indoor floor dust appears to be residues of detergent in clothing. Thus, a newly washed shirt contained 2960 microgram...

  10. Superior critical current density obtained in MgB{sub 2} bulks via employing carbon-coated boron and minor Cu addition

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Junming; Liu, Yongchang [State Key Laboratory of Hydraulic Engineering Simulation and Safety, School of Materials Science & Engineering, Tianjin University, Tianjin 300072 (China); Ma, Zongqing, E-mail: mzq0320@163.com [State Key Laboratory of Hydraulic Engineering Simulation and Safety, School of Materials Science & Engineering, Tianjin University, Tianjin 300072 (China); Institute for Superconducting and Electronic Materials, AIIM, University of Wollongong, Squires Way, North Wollongong, NSW 2500 (Australia); Shahriar Al Hossain, M. [Institute for Superconducting and Electronic Materials, AIIM, University of Wollongong, Squires Way, North Wollongong, NSW 2500 (Australia); Xin, Ying; Jin, Jianxun [Tianjin University – Futong Group Research Center of Applied Superconductivity, Tianjin University, Tianjin 300072 (China)

    2016-09-15

    Highlights: • Usage of carbon-coated boron leads to high level of homogeneous carbon doping. • Cu addition improves MgB{sub 2} grain connectivity, leading to higher J{sub c} at low fields. • Cu addition reduces MgO impurity, also contributing to the improvement of J{sub c}. - Abstract: High performance Cu doped MgB{sub 2} bulks were prepared by an in-situ method with carbon-coated amorphous boron as precursor. It was found that the usage of carbon-coated boron in present work leads to the formation of uniformly refined MgB{sub 2} grains, as well as a high level of homogeneous carbon doping in the MgB{sub 2} samples, which significantly enhance the J{sub c} in both Cu doped and undoped bulks compared to MgB{sub 2} bulks with normal amorphous boron precursor. Moreover, minor Cu can service as activator, and thus facilitates the growth of MgB{sub 2} grains and improves crystallinity and grain connectivity, which can bring about the excellent critical current density (J{sub c}) at self fields and low fields (the best values are 7 × 10{sup 5} A/cm{sup 2} at self fields, and 1 × 10{sup 5} A/cm{sup 2} at 2 T, 20 K, respectively). Simultaneously, minor Cu addition can reduce the amount of MgO impurity significantly, also contributing to the improvement of J{sub c} at low fields. Our work suggests that Cu-activated sintering combined with employment of carbon-coated amorphous boron as precursor could be a promising technique to produce practical MgB{sub 2} bulks or wires with excellent J{sub c} on an industrial scale.

  11. Cast bulk metallic glass alloys: prospects as wear materials

    Energy Technology Data Exchange (ETDEWEB)

    Hawk, Jeffrey A.; Dogan, Omer N.; Shiflet, Gary J. (Dept. of Materials Science and Engineering, University of Virginia, Charlottesville, VA)

    2005-01-01

    Bulk metallic glasses are single phase materials with unusual physical and mechanical properties. One intriguing area of possible use is as a wear material. Usually, pure metals and single phase dilute alloys do not perform well in tribological conditions. When the metal or alloy is lightweight, it is usually soft leading to galling in sliding situations. For the harder metals and alloys, their density is usually high, so there is an energy penalty when using these materials in wear situations. However, bulk metallic glasses at the same density are usually harder than corresponding metals and dilute single phase alloys, and so could offer better wear resistance. This work will discuss preliminary wear results for metallic glasses with densities in the range of 4.5 to 7.9 g/cc. The wear behavior of these materials will be compared to similar metals and alloys.

  12. Effects of Floor Covering Resistance of a Radiant Floor on System Energy and Exergy Performances

    DEFF Research Database (Denmark)

    Kazanci, Ongun Berk; Shukuya, Masanori; Olesen, Bjarne W.

    2016-01-01

    Floor covering resistance (material and thickness) can be influenced by subjective choices (architectural design, interior design, texture, etc.) with significant effects on the performance of a radiant heating and cooling system. To study the effects of floor covering resistance on system...... performance, a water-based radiant floor heating and cooling system (dry, wooden construction) was considered to be coupled to an air-to-water heat pump, and the effects of varying floor covering resistances (0.05 m2K/W, 0.09 m2K/W and 0.15 m2K/W) on system performance were analyzed in terms of energy...... and exergy. In order to achieve the same heating and cooling outputs, higher average water temperatures are required in the heating mode (and lower temperatures in the cooling mode) with increasing floor covering resistance. These temperature requirements decrease the heat pump’s performance (lower...

  13. Nucleonic density gauging -- an application in a chemical industry

    International Nuclear Information System (INIS)

    Rao, S.S.; Kirti; Jain, S.K.

    1979-01-01

    Hardly any conventional technique is available for on-line bulk density measurement. A typical problem of measurement of bulk density of detergent powder during production has been tackled. The nucleonic bulk density gauge developed by the Bhabha Atomic Research Centre, Bombay, is briefly explained. Problems of source selection, collimation of radiation, detection system, etc are described. Adequate compensation for environmental temperature changes was achieved. Tests on stability, etc were carried out in the laboratory and the plant. The experience in actual use is mentioned. With some modifications the system developed can be extended for density measurement and control of liquids, slurries, etc. Improvement in output linearity is also possible. (auth.)

  14. A comparative study on thermal efficiency between the present floor and a ceramic floor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y.M.; Kim, K.S. [Korea Institute of Science and Technology, Seoul (Korea, Republic of); Choi, B.S. [Kyung Hee University, Yongin (Korea, Republic of); Ko, J.S.; Park, S.K. [Bomwoo and Co. LTD., Kwangju (Korea, Republic of)

    1999-04-01

    A ceramic floor with improved thermal conductivity and efficiency has been developed in this study. The new ceramic floor minimizes the shrinkage rate to below 0.07% and shows almost no cleavage. There is no need to repair the ceramic floor because its bottom surface is flat. It especially shows an excellent performance in the test of a compressive strength (300 kg/cm{sup 2} based on 28 days), a flexural strength (64 kg/cm{sup 2} based on 28 days), and a convenient pressing. It is lighter than the present floor and it is expected to be applicable for a self-leveling ceramic motar in the residences and apartments. It shows an excellent character in the thermal conductivity and other physical properties compare to the present cement mortar. 5 refs., 3 figs., 2 tabs.

  15. Floors: Care and Maintenance.

    Science.gov (United States)

    Post Office Dept., Washington, DC.

    Guidelines, methods and policies regarding the care and maintenance of post office building floors are overviewed in this handbook. Procedures outlined are concerned with maintaining a required level of appearance without wasting manpower. Flooring types and characteristics and the particular cleaning requirements of each type are given along with…

  16. A density gradient theory based method for surface tension calculations

    DEFF Research Database (Denmark)

    Liang, Xiaodong; Michelsen, Michael Locht; Kontogeorgis, Georgios

    2016-01-01

    The density gradient theory has been becoming a widely used framework for calculating surface tension, within which the same equation of state is used for the interface and bulk phases, because it is a theoretically sound, consistent and computationally affordable approach. Based on the observation...... that the optimal density path from the geometric mean density gradient theory passes the saddle point of the tangent plane distance to the bulk phases, we propose to estimate surface tension with an approximate density path profile that goes through this saddle point. The linear density gradient theory, which...... assumes linearly distributed densities between the two bulk phases, has also been investigated. Numerical problems do not occur with these density path profiles. These two approximation methods together with the full density gradient theory have been used to calculate the surface tension of various...

  17. Measurements of anomalous neutron transport in bulk graphite

    International Nuclear Information System (INIS)

    Bowman, C.D.; Smith, G.A.; Vogelaar, B.; Howell, C.R.; Bilpuch, E.G.; Tornow, W.

    2003-01-01

    The neutron absorption of bulk granular graphite has been measured in a classical exponential diffusion experiment. Our first measurements of April 2002 implementing both exponential decay and pulsed die-away experiments and using the TUNL pulsed accelerator at Duke University as a neutron source indicated a capture cross section for graphite a striking factor of three lower than the measured value for carbon of 3.4 millibarns. Therefore a new exponential experiment with an improved geometry enabling greater accuracy has been performed giving an apparent cross section for carbon in the form of bulk granular graphite of less than 0.5 millibarns. This result confirms our first result and is also consistent with less than one part per million of boron in our graphite. The bulk density of the graphite is 1.02 compared with the actual particle density of 1.60 indicating a packing fraction of 0.64 or a void fraction of 0.36. We suspect that the apparent suppression of absorption in bulk graphite may be associated with the strong coherent diffraction of neutrons that dominates neutron transport in graphite. Coherent diffraction has never been taken into account in graphite reactor design and no neutron transport code including general use codes such as MCNP incorporate diffraction effects even though diffraction dominates many practical thermal neutron transport problems. (orig.)

  18. Measurements of anomalous neutron transport in bulk graphite

    Energy Technology Data Exchange (ETDEWEB)

    Bowman, C.D.; Smith, G.A. [ADNA Corp., Los Alamos, NM (United States); Vogelaar, B. [Virginia Tech., Blacksburg, VA (United States); Howell, C.R.; Bilpuch, E.G.; Tornow, W. [Triangle Univ. Nuclear Lab., Duke Univ., Durham, NC (United States)

    2003-07-01

    The neutron absorption of bulk granular graphite has been measured in a classical exponential diffusion experiment. Our first measurements of April 2002 implementing both exponential decay and pulsed die-away experiments and using the TUNL pulsed accelerator at Duke University as a neutron source indicated a capture cross section for graphite a striking factor of three lower than the measured value for carbon of 3.4 millibarns. Therefore a new exponential experiment with an improved geometry enabling greater accuracy has been performed giving an apparent cross section for carbon in the form of bulk granular graphite of less than 0.5 millibarns. This result confirms our first result and is also consistent with less than one part per million of boron in our graphite. The bulk density of the graphite is 1.02 compared with the actual particle density of 1.60 indicating a packing fraction of 0.64 or a void fraction of 0.36. We suspect that the apparent suppression of absorption in bulk graphite may be associated with the strong coherent diffraction of neutrons that dominates neutron transport in graphite. Coherent diffraction has never been taken into account in graphite reactor design and no neutron transport code including general use codes such as MCNP incorporate diffraction effects even though diffraction dominates many practical thermal neutron transport problems. (orig.)

  19. Building with electromagnetic shield structure for individual floors

    International Nuclear Information System (INIS)

    Takahashi, T.; Nakamura, M.; Yabana, Y.; Ishikawa, T.; Nagata, K.

    1991-01-01

    This invention relates to a building having a floor-by-floor electromagnetic shield structure well-suited for application to an information network system in which an electromagnetically shielded space is divided by individual floors and electric waves are utilized within the building on a floor-by-floor basis. (author). 8 figs

  20. Building with electromagnetic shield structure for individual floors

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, T; Nakamura, M; Yabana, Y; Ishikawa, T; Nagata, K

    1991-09-10

    This invention relates to a building having a floor-by-floor electromagnetic shield structure well-suited for application to an information network system in which an electromagnetically shielded space is divided by individual floors and electric waves are utilized within the building on a floor-by-floor basis. (author). 8 figs.

  1. Collapse of Incoherent Light Beams in Inertial Bulk Kerr Media

    DEFF Research Database (Denmark)

    Bang, Ole; Edmundson, Darran; Królikowski, Wieslaw

    1999-01-01

    We use the coherent density function theory to show that partially coherent beams are unstable and may collapse in inertial bulk Kerr media. The threshold power for collapse, and its dependence on the degree of coherence, is found analytically and checked-numerically. The internal dynamics of the...... of the walk-off modes is illustrated for collapsing and diffracting partially coherent beams.......We use the coherent density function theory to show that partially coherent beams are unstable and may collapse in inertial bulk Kerr media. The threshold power for collapse, and its dependence on the degree of coherence, is found analytically and checked-numerically. The internal dynamics...

  2. Trapped magnetic field measurements on HTS bulk by peak controlled pulsed field magnetization

    International Nuclear Information System (INIS)

    Ida, Tetsuya; Watasaki, Masahiro; Kimura, Yosuke; Miki, Motohiro; Izumi, Mitsuru

    2010-01-01

    For the past several years, we have studied the high-temperature superconducting (HTS) synchronous motor assembled with melt-textured Gd-Ba-Cu-O bulk magnets. If the single pulse field magnetizes a bulk effectively, size of electrical motor will become small for the strong magnetic field of the HTS magnets without reducing output power of motor. In the previous study, we showed that the HTS bulk was magnetized to excellent cone-shape magnetic field distribution by using the waveform control pulse magnetization (WCPM) method. The WCPM technique made possible the active control of the waveform on which magnetic flux motion depended. We generated the pulse waveform with controlled risetime for HTS bulk magnetization to suppress the magnetic flux motion which decreases magnetization efficiency. The pulsed maximum magnetic flux density with slow risetime is not beyond the maximum magnetic flux density which is trapped by the static field magnetization. But, as for applying the pulse which has fast risetime, the magnetic flux which exceed greatly the threshold penetrates the bulk and causes the disorder of the trapped magnetic distribution. This fact suggests the possibility that the threshold at pulsed magnetization influences the dynamic magnetic flux motion. In this study, Gd-Ba-Cu-O bulk is magnetized by the controlled arbitrary trapezoidal shape pulse, of which the maximum magnetic flux density is controlled not to exceed the threshold. We will present the trapped magnetic characteristics and the technique to generate the controlled pulsed field.

  3. An overview of rotating machine systems with high-temperature bulk superconductors

    Science.gov (United States)

    Zhou, Difan; Izumi, Mitsuru; Miki, Motohiro; Felder, Brice; Ida, Tetsuya; Kitano, Masahiro

    2012-10-01

    The paper contains a review of recent advancements in rotating machines with bulk high-temperature superconductors (HTS). The high critical current density of bulk HTS enables us to design rotating machines with a compact configuration in a practical scheme. The development of an axial-gap-type trapped flux synchronous rotating machine together with the systematic research works at the Tokyo University of Marine Science and Technology since 2001 are briefly introduced. Developments in bulk HTS rotating machines in other research groups are also summarized. The key issues of bulk HTS machines, including material progress of bulk HTS, in situ magnetization, and cooling together with AC loss at low-temperature operation are discussed.

  4. Bulk and mechanical properties of the Paintbrush tuff recovered from borehole USW NRG-6: Data report

    International Nuclear Information System (INIS)

    Martin, R.J.; Boyd, P.J.; Noel, J.S.; Price, R.H.

    1994-11-01

    Experimental results are presented for bulk and mechanical properties measurements on specimens of the Paintbrush tuff recovered from borehole USW NRG-6 at Yucca Mountain, Nevada. Measurements have been performed on four thermal/mechanical units, TCw, PTn, TSw1 and TSw2. On each specimen the following bulk properties have been reported: dry bulk density, saturated bulk density, average grain density, and porosity. Unconfined compression to failure, confined compression to failure, and indirect tensile strength tests were performed on selected specimens recovered from the borehole. In addition, compressional and shear wave velocities were measured on specimens designated for unconfined compression and confined compression experiments. Measurements were conducted at room temperature on nominally water saturated specimens; however, some specimens of PTn were tested in a room dry condition. The nominal strain rate for the fracture experiments was 10 -5 s -1

  5. Large-scale HTS bulks for magnetic application

    Science.gov (United States)

    Werfel, Frank N.; Floegel-Delor, Uta; Riedel, Thomas; Goebel, Bernd; Rothfeld, Rolf; Schirrmeister, Peter; Wippich, Dieter

    2013-01-01

    ATZ Company has constructed about 130 HTS magnet systems using high-Tc bulk magnets. A key feature in scaling-up is the fabrication of YBCO melts textured multi-seeded large bulks with three to eight seeds. Except of levitation, magnetization, trapped field and hysteresis, we review system engineering parameters of HTS magnetic linear and rotational bearings like compactness, cryogenics, power density, efficiency and robust construction. We examine mobile compact YBCO bulk magnet platforms cooled with LN2 and Stirling cryo-cooler for demonstrator use. Compact cryostats for Maglev train operation contain 24 pieces of 3-seed bulks and can levitate 2500-3000 N at 10 mm above a permanent magnet (PM) track. The effective magnetic distance of the thermally insulated bulks is 2 mm only; the stored 2.5 l LN2 allows more than 24 h operation without refilling. 34 HTS Maglev vacuum cryostats are manufactured tested and operate in Germany, China and Brazil. The magnetic levitation load to weight ratio is more than 15, and by group assembling the HTS cryostats under vehicles up to 5 t total loads levitated above a magnetic track is achieved.

  6. Bulk Superconductors in Mobile Application

    Science.gov (United States)

    Werfel, F. N.; Delor, U. Floegel-; Rothfeld, R.; Riedel, T.; Wippich, D.; Goebel, B.; Schirrmeister, P.

    We investigate and review concepts of multi - seeded REBCO bulk superconductors in mobile application. ATZ's compact HTS bulk magnets can trap routinely 1 T@77 K. Except of magnetization, flux creep and hysteresis, industrial - like properties as compactness, power density, and robustness are of major device interest if mobility and light-weight construction is in focus. For mobile application in levitated trains or demonstrator magnets we examine the performance of on-board cryogenics either by LN2 or cryo-cooler application. The mechanical, electric and thermodynamical requirements of compact vacuum cryostats for Maglev train operation were studied systematically. More than 30 units are manufactured and tested. The attractive load to weight ratio is more than 10 and favours group module device constructions up to 5 t load on permanent magnet (PM) track. A transportable and compact YBCO bulk magnet cooled with in-situ 4 Watt Stirling cryo-cooler for 50 - 80 K operation is investigated. Low cooling power and effective HTS cold mass drives the system construction to a minimum - thermal loss and light-weight design.

  7. Materials processing, pulsed field magnetization and field-pole application to propulsion motors on Gd123 bulk superconductors

    International Nuclear Information System (INIS)

    Izumi, M; Xu, C; Xu, Y; Morita, E; Kimura, Y; Hu, A; Ichihara, M; Murakami, M; Sakai, N; Hirabayashi, I; Sugimoto, H; Miki, M

    2008-01-01

    Gd123 bulk superconductor is one of the promising magnet materials. We studied the materials processing to grow high performance magnet with a doping of nano-sized metal oxides such as ZrO 2 as a candidature of pinning centre. The enhancement of the critical current density was obtained. Growth of nano-sized particles of Gd211 in addition to BaZrO 3 were observed by TEM. The formation of nano-sized particles appears a key to improve the integrated flux trapped inside the bulks and the TEM reveals an intriguing effect of the addition to the microstructure of bulk materials. Magnetization process is crucial especially for an extended machinery. Pulsed field magnetization was applied to the field-pole bulk on the rotor disk of the tested synchronous motor. The trapped flux density of 1.3 T for Gd123 bulk sample and of 60 mm diameter was reached in the limited dimension of the tested motor by a step cooling method down to 38 K with a closed-cycle condensed neon. The pulsed magnetic field was applied with a new type of split-armature coil. A large bulk of 140 mm diameter has also shown a potential flux trapping superior to other smaller specimens. The bulk magnet provides a strong magnetic field around the bulk body itself with high current density relative to a coil winding. A comparative drawing of a 'torque density' of a variety of motors which is defined as the torque divided by the volume of the motor indicates a potential advantage of bulk motor as a super permanent magnet motor

  8. Flooring choices for newborn ICUs.

    Science.gov (United States)

    White, R D

    2007-12-01

    Floors are a major element of newborn intensive care unit (NICU) construction. They provide visual cues, sound control, and with certain materials, some degree of physical comfort for workers. Flooring materials may entail a significant cost for installation and upkeep and can have substantial ecological impact, both in the choice of the flooring itself, as well as the substances used to clean it. In this article the important aspects to consider for each factor are explored and recommendations are offered for appropriate choices in various NICU areas.

  9. Impacts of feedlot floor condition, deposition frequency, and inhibitors on N2O and CH4 emissions from feedlot dung and urine patches.

    Science.gov (United States)

    Liao, Wenhua; Liu, Chunjing; Gao, Zhiling

    2018-04-09

    Patches of dung and urine are major contributors to the feedlot gas emissions. This study investigated the impacts of dung deposition frequency (partly reflecting animal stocking density of a feedlot), dairy feedlot floor conditions (old floor indicated with the presence of consolidated manure pad [CMP] vs. new floor with the absence of consolidated manure pad [CMPn]), and application of dicyandiamide (DCD) and hydroquinone (HQ) on nitrous oxide (N 2 O) and methane (CH 4 ) emissions from patches in the laboratory, and the integrative impacts were expressed in terms of global warming potential (CO 2 -equivalent). Dung deposition frequency, feedlot floor condition, and application of inhibitors showed inverse impacts on N 2 O and CH 4 emissions from patches. Greenhouse gas (GHG) emissions from the dung, urine, and dung+urine patches on the CMP feedlot surface were approximately 7.48, 87.35, and 7.10 times those on the CMPn feedlot surface (P emissions from CMP and CMPn feedlot surfaces under high deposition frequency condition were approximately 10 and 1.7 times those under low-frequency condition. Moreover, application of HQ slightly reduced the GHG emission from urine patches, by 14.9% (P > 0.05), while applying DCD or DCD+HQ significantly reduced the GHG, by 60.3% and 65.0%, respectively (P emission factors for feedlots. In the future, field measurements to quantitatively evaluate the relative contribution of nitrification and denitrification to the N 2 O emissions of feedlot surfaces are highly required for effective N 2 O control. This study shows that feedlot CH 4 and N 2 O emissions inversely respond to the dicyandiamide (DCD) application. Applying DCD significantly reduces GHG emissions of feedlot urine patches. Feedlot floor condition and stocking density strongly impact feedlot GHG emissions. Including feedlot floor condition and stocking density in the feedlot EF determining process is necessary.

  10. Influence of grain boundary connectivity on the trapped magnetic flux of multi-seeded bulk superconductors

    Science.gov (United States)

    Deng, Z.; Miki, M.; Felder, B.; Tsuzuki, K.; Shinohara, N.; Hara, S.; Uetake, T.; Izumi, M.

    2011-09-01

    The top-seeded melt-growth process with multi-seeding technique provides a promising way to fabricate large-sized bulk superconductors in an economical way. To understand the essential characteristics of the multi-seeded bulks, the paper reports the influence of the grain boundary (GB) coupling or connectivity on the total trapped magnetic flux. The coupling ratio, the lowest trapped flux density in the GB area to the averaged top value of the two neighboring peak trapped fields, is introduced to reflect the coupling quality of GBs inside a multi-seeded bulk. By the trapped flux density measurement of four different performance multi-seeded YBCO bulk samples as representatives, it was found that the GB coupling plays an important role for the improvement of the total trapped magnetic flux; moreover, somewhat more significant than the widely used parameter of the peak trapped fields to evaluate the physical performance of bulk samples. This characteristic is different with the case of the well-grown single-grain bulks.

  11. Simulations of floor cooling system capacity

    International Nuclear Information System (INIS)

    Odyjas, Andrzej; Górka, Andrzej

    2013-01-01

    Floor cooling system capacity depends on its physical and operative parameters. Using numerical simulations, it appears that cooling capacity of the system largely depends on the type of cooling loads occurring in the room. In the case of convective cooling loads capacity of the system is small. However, when radiation flux falls directly on the floor the system significantly increases productivity. The article describes the results of numerical simulations which allow to determine system capacity in steady thermal conditions, depending on the type of physical parameters of the system and the type of cooling load occurring in the room. Moreover, the paper sets out the limits of system capacity while maintaining a minimum temperature of the floor surface equal to 20 °C. The results are helpful for designing system capacity in different type of cooling loads and show maximum system capacity in acceptable thermal comfort condition. -- Highlights: ► We have developed numerical model for simulation of floor cooling system. ► We have described floor system capacity depending on its physical parameters. ► We have described floor system capacity depending on type of cooling loads. ► The most important in the obtained cooling capacities is the type of cooling loads. ► The paper sets out the possible maximum cooling floor system capacity

  12. Reversible ultrafast melting in bulk CdSe

    International Nuclear Information System (INIS)

    Wu, Wenzhi; He, Feng; Wang, Yaguo

    2016-01-01

    In this work, transient reflectivity changes in bulk CdSe have been measured with two-color femtosecond pump-probe spectroscopy under a wide range of pump fluences. Three regions of reflectivity change with pump fluences have been consistently revealed for excited carrier density, coherent phonon amplitude, and lattice temperature. For laser fluences from 13 to 19.3 mJ/cm 2 , ultrafast melting happens in first several picoseconds. This melting process is purely thermal and reversible. A complete phase transformation in bulk CdSe may be reached when the absorbed laser energy is localized long enough, as observed in nanocrystalline CdSe

  13. Bulk Density Prediction for Histosols and Soil Horizons with High Organic Matter Content

    Directory of Open Access Journals (Sweden)

    Sidinei Julio Beutler

    Full Text Available ABSTRACT Bulk density (Bd can easily be predicted from other data using pedotransfer functions (PTF. The present study developed two PTFs (PTF1 and PTF2 for Bd prediction in Brazilian organic soils and horizons and compared their performance with nine previously published equations. Samples of 280 organic soil horizons used to develop PTFs and containing at least 80 g kg-1 total carbon content (TOC were obtained from different regions of Brazil. The multiple linear stepwise regression technique was applied to validate all the equations using an independent data set. Data were transformed using Box-Cox to meet the assumptions of the regression models. For validation of PTF1 and PTF2, the coefficient of determination (R2 was 0.47 and 0.37, mean error -0.04 and 0.10, and root mean square error 0.22 and 0.26, respectively. The best performance was obtained for the PTF1, PTF2, Hollis, and Honeysett equations. The PTF1 equation is recommended when clay content data are available, but considering that they are scarce for organic soils, the PTF2, Hollis, and Honeysett equations are the most suitable because they use TOC as a predictor variable. Considering the particular characteristics of organic soils and the environmental context in which they are formed, the equations developed showed good accuracy in predicting Bd compared with already existing equations.

  14. Formaldehyde and TVOC emission behavior of laminate flooring by structure of laminate flooring and heating condition.

    Science.gov (United States)

    An, Jae-Yoon; Kim, Sumin; Kim, Hyun-Joong

    2011-03-15

    Formaldehyde was measured with a desiccator, a 20 L chamber and the FLEC method. The formaldehyde emission rate from laminate was the highest at 32 °C using the desiccator, which then decreased with time. The formaldehyde emission using the 20 L small chamber and FLEC showed a similar tendency. There was a strong correlation between the formaldehyde and total volatile organic compounds (TVOCs) with both types of floorings using the two different methods. The formaldehyde emission rate and TVOC results were higher when tested using the FLEC method than with the 20 L small chamber method. The emission rate was affected by the joint edge length in laminate flooring. Toluene, ethylbenzene and xylene were the main VOCs emitted from laminate flooring, and there were more unidentified VOCs emitted than identified VOCs. The samples heated with a floor heating system emitted more formaldehyde than those heated using an air circulation system due to the temperature difference between the bottom panel and flooring. The TVOC emission level of the samples was higher when an air circulation system was used than when a floor heating system was used due to the high ventilation rate. Copyright © 2010 Elsevier B.V. All rights reserved.

  15. Crustal Ages of the Ocean Floor - Poster

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Crustal Ages of the Ocean Floor Poster was created at NGDC using the Crustal Ages of the Ocean Floor database draped digitally over a relief of the ocean floor...

  16. Ab-initio investigations of the electronic properties of bulk wurtzite Beryllia and its derived nanofilms

    International Nuclear Information System (INIS)

    Goumri-Said, Souraya; Kanoun, Mohammed Benali

    2010-01-01

    In this Letter we investigate the electronic properties of the bulk and the nanofilm BeO in wurtzite structure. We performed a first-principles pseudo-potential method within the generalized gradient approximation. We will give more importance to the changes in band structure and density of states between the bulk structure and its derived nanofilms. The bonding characterization will be investigated via the analysis Mulliken population and charge density contours. It is found that the nanofilm retains the same properties as its bulk structure with slight changes in electronic properties and band structure which may offer some unusual transport properties.

  17. 75 FR 66126 - Multilayered Wood Flooring From China

    Science.gov (United States)

    2010-10-27

    ...)] Multilayered Wood Flooring From China AGENCY: United States International Trade Commission. ACTION: Institution... flooring, provided for in subheadings 4409.10, 4409.29, 4412.31, 4412.32, 4412.39, 4412.94, 4412.99, 4418... multilayered wood flooring. The following companies are members of the CAHP: Anderson Hardwood Floors, LLC...

  18. 75 FR 79019 - Multilayered Wood Flooring From China

    Science.gov (United States)

    2010-12-17

    ...)] Multilayered Wood Flooring From China Determinations On the basis of the record \\1\\ developed in the subject... imports from China of multilayered wood flooring, provided for in subheadings 4409.10, 4409.29, 4412.31... multilayered wood flooring. The following companies are members of the CAHP: Anderson Hardwood Floors, LLC...

  19. Mode of delivery and Pelvic floor disorder

    International Nuclear Information System (INIS)

    Noor, R.; Neelam, H.; Bashir, M.S.

    2017-01-01

    Objective: To compare pelvic floor dysfunction in non pregnant women who had delivered vaginally versus those with cesarean delivery. Methodology: The prevalence of pelvic floor disorders among non pregnant women was assesses by using a standardized tool pelvic floor distress inventory short form (PFDI-20). Data was collected from Jinnah Hospital Lahore, Pakistan. Results: Total numbers of participants were 278. 47.12% subjects had moderate, 36.69% miner and 16.19% had severe pelvic floor dysfunction. The symptoms of pelvic organ prolapse were more prevalent (mean value is 59.1876) than Urinary Distress (mean value is 40.5426), while the Colorectal-Anal Distress (mean value is 35.9150) were least prevalent. Conclusion: Pelvic floor disorders are very common among females and are strongly associated with mode of delivery. Although spontaneous vaginal birth was extensively associated with pelvic floor disorders the instrumental delivery affects most. (author)

  20. Functional anatomy of pelvic floor

    Directory of Open Access Journals (Sweden)

    Salvatore Rocca Rossetti

    2016-03-01

    Full Text Available Generally, descriptions of the pelvic floor are discordant, since its complex structures and the complexity of pathological disorders of such structures; commonly the descriptions are sectorial, concerning muscles, fascial developments, ligaments and so on. On the contrary to understand completely nature and function of the pelvic floor it is necessary to study it in the most unitary view and in the most global aspect, considering embriology, philogenesy, anthropologic development and its multiple activities others than urological, gynaecological and intestinal ones. Recent acquirements succeeded in clarifying many aspects of pelvic floor activity, whose musculature has been investigated through electromyography, sonography, magnetic resonance, histology, histochemistry, molecular research. Utilizing recent research concerning not only urinary and gynecologic aspects but also those regarding statics and dynamics of pelvis and its floor, it is now possible to study this important body part as a unit; that means to consider it in the whole body economy to which maintaining upright position, walking and behavior or physical conduct do not share less than urinary, genital, and intestinal functions. It is today possible to consider the pelvic floor as a musclefascial unit with synergic and antagonistic activity of muscular bundles, among them more or less interlaced, with multiple functions and not only the function of pelvic cup closure.

  1. Gd-123 bulk field pole magnets cooled with condensed neon for axial-gap type synchronous motor

    International Nuclear Information System (INIS)

    Sano, T.; Kimura, Y.; Sugyo, D.; Yamaguchi, K.; Izumi, M.; Ida, T.; Sugimoto, H.; Miki, M.

    2008-01-01

    We have conducted to develop an axial-gap type synchronous propulsion motor with Gd-bulk HTS field pole magnets. It has been established on the fundamental technology upon the liquid nitrogen cooling. In the present study, we aimed an output improvement of the motor by the magnetic flux density enhancement of the bulk HTS, in a word, the trapped magnetic flux density on the HTS bulk. The output of the motor depends on the physics of the motor, the magnetic flux density, and the electric current density flowing through the armature. We have employed a condensed neon with a helium GM refrigerator. The bulk HTS placed on the rotor disk inside the motor frame was successfully cooled down with circulating condensed neon. The temperature at the bulk HTS surface reached 38 K. Upon magnetization, we developed controlled magnetic field density distribution coil (CMDC) composed of a couple of pulsed copper armature coil. In the magnetization procedure, with decreasing magnetization temperature, minute by minute, after Sander and Kamijyo that the step cooling magnetization method was used. In addition, the CMDC coil has enabled to control the applied flux distribution. Three parameters as the temperature, the applied magnetic field, and the effective applied flux density distribution were changed within eight times pulsed magnetizations in total. Up to 4th pulsed magnetization, we kept (1st step) high temperature, and subsequent pulsed magnetizations were done at low temperature. As a result, the highest maximum trapped magnetic flux density was reached 1.31 T, about 2.5 times compared to the value obtained upon cooling with liquid nitrogen. Consequently, the output of the motor has been enhanced to 25 kW from 10 kW taken in the previous operation

  2. External Hand Forces Exerted by Long-Term Care Staff to Push Floor-Based Lifts: Effects of Flooring System and Resident Weight.

    Science.gov (United States)

    Lachance, Chantelle C; Korall, Alexandra M B; Russell, Colin M; Feldman, Fabio; Robinovitch, Stephen N; Mackey, Dawn C

    2016-09-01

    The aim of this study was to investigate the effects of flooring type and resident weight on external hand forces required to push floor-based lifts in long-term care (LTC). Novel compliant flooring is designed to reduce fall-related injuries among LTC residents but may increase forces required for staff to perform pushing tasks. A motorized lift may offset the effect of flooring on push forces. Fourteen female LTC staff performed straight-line pushes with two floor-based lifts (conventional, motor driven) loaded with passengers of average and 90th-percentile resident weights over four flooring systems (concrete+vinyl, compliant+vinyl, concrete+carpet, compliant+carpet). Initial and sustained push forces were measured by a handlebar-mounted triaxial load cell and compared to participant-specific tolerance limits. Participants rated pushing difficulty. Novel compliant flooring increased initial and sustained push forces and subjective ratings compared to concrete flooring. Compared to the conventional lift, the motor-driven lift substantially reduced initial and sustained push forces and perceived difficulty of pushing for all four floors and both resident weights. Participants exerted forces above published tolerance limits only when using the conventional lift on the carpet conditions (concrete+carpet, compliant+carpet). With the motor-driven lift only, resident weight did not affect push forces. Novel compliant flooring increased linear push forces generated by LTC staff using floor-based lifts, but forces did not exceed tolerance limits when pushing over compliant+vinyl. The motor-driven lift substantially reduced push forces compared to the conventional lift. Results may help to address risk of work-related musculoskeletal injury, especially in locations with novel compliant flooring. © 2016, Human Factors and Ergonomics Society.

  3. 76 FR 76435 - Multilayered Wood Flooring From China

    Science.gov (United States)

    2011-12-07

    ...)] Multilayered Wood Flooring From China Determinations On the basis of the record \\1\\ developed in the subject... multilayered wood flooring, provided for in subheadings 4409.10, 4409.29, 4412.31, 4412.32, 4412.39, 4412.94... flooring. The following companies are members of the CAHP: Anderson Hardwood Floors, LLC, Fountain Inn, SC...

  4. The homogeneity of levitation force in single domain YBCO bulk

    International Nuclear Information System (INIS)

    Zhou Keran; Xu Kexi; Wu Xingda; Pan Pengjun

    2007-01-01

    The pellet homogeneity of levitation force versus the position in comparison to the seed or to the top surface has been studied in the entire volume of a single domain YBa 2 Cu 3 O 7-δ bulk sample processed by the top-seeded melt texturing growth (TSMTG). It is found that the levitation forces increase and peak at a depth of 3 mm from the top of the sample at liquid nitrogen temperature. In other words, the second disk has the largest levitation force density. The phenomenon can be interpreted by the interaction between the microcracks or pores produced by crystal growth and the oxygenation. We propose a model in which Y211 particles distribution leading to microcracks and pores reduces the effective induced shielding current loops (ISCL) and increases the perimeters of ISCL. This corresponds to a decrease in the grain size and results in greatly reduced levitation forces of the bottom of the bulk. From the research, we know that the density of the YBCO bulk is also an important parameter for the levitation properties. The result is very attractive and useful for the fundamental studies and fabrication of TSMTG YBa 2 Cu 3 O 7-δ bulk

  5. The homogeneity of levitation force in single domain YBCO bulk

    Science.gov (United States)

    Zhou, Keran; Xu, Ke-Xi; Wu, Xing-da; Pan, Peng-jun

    2007-11-01

    The pellet homogeneity of levitation force versus the position in comparison to the seed or to the top surface has been studied in the entire volume of a single domain YBa 2Cu 3O 7-δ bulk sample processed by the top-seeded melt texturing growth (TSMTG). It is found that the levitation forces increase and peak at a depth of 3 mm from the top of the sample at liquid nitrogen temperature. In other words, the second disk has the largest levitation force density. The phenomenon can be interpreted by the interaction between the microcracks or pores produced by crystal growth and the oxygenation. We propose a model in which Y211 particles distribution leading to microcracks and pores reduces the effective induced shielding current loops (ISCL) and increases the perimeters of ISCL. This corresponds to a decrease in the grain size and results in greatly reduced levitation forces of the bottom of the bulk. From the research, we know that the density of the YBCO bulk is also an important parameter for the levitation properties. The result is very attractive and useful for the fundamental studies and fabrication of TSMTG YBa 2Cu 3O 7-δ bulk.

  6. A trapped field of >3 T in bulk MgB2 fabricated by uniaxial hot pressing

    International Nuclear Information System (INIS)

    Durrell, J H; Dennis, A; Shi, Y; Xu, Z; Campbell, A M; Babu, N Hari; Cardwell, D A; Dancer, C E J; Todd, R I; Grovenor, C R M

    2012-01-01

    A trapped field of over 3 T has been measured at 17.5 K in a magnetized stack of two disc-shaped bulk MgB 2 superconductors of diameter 25 mm and thickness 5.4 mm. The bulk MgB 2 samples were fabricated by uniaxial hot pressing, which is a readily scalable, industrial technique, to 91% of their maximum theoretical density. The macroscopic critical current density derived from the trapped field data using the Biot–Savart law is consistent with the measured local critical current density. From this we conclude that critical current density, and therefore trapped field performance, is limited by the flux pinning available in MgB 2 , rather than by lack of connectivity. This suggests strongly that both increasing sample size and enhancing pinning through doping will allow further increases in trapped field performance of bulk MgB 2 . (rapid communication)

  7. Critical current density in MgB2 bulk samples after co-doping with nano-SiC and poly zinc acrylate complexes

    International Nuclear Information System (INIS)

    Zhang, Z.; Suo, H.; Ma, L.; Zhang, T.; Liu, M.; Zhou, M.

    2011-01-01

    SiC and poly zinc acrylate complexes co-doped MgB 2 bulk has been synthesized. Co-doping can cause higher carbon substitutions and the second phase particles. Co-doping can further increase the Jc value of MgB 2 bulk on the base of the SiC doping. The co-doped MgB 2 bulk samples have been synthesized using an in situ reaction processing. The additives is 8 wt.% SiC nano powders and 10 wt.% [(CH 2 CHCOO) 2 Zn] n poly zinc acrylate complexes (PZA). A systematic study was performed on samples doped with SiC or PZA and samples co-doped with both of them. The effects of doping and co-doping on phase formation, microstructure, and the variation of lattice parameters were studied. The amount of substituted carbon, the critical temperature (T c ) and the critical current density (J c ) were determined. The calculated lattice parameters show the decrease of the a-axis, while no obvious change was detected for c-axis parameter in co-doped samples. This indicates that the carbon was substituted by boron in MgB 2 . The amount of substituted carbon for the co-doped sample shows an enhancement compared to that of the both single doped samples. The co-doped samples perform the highest J c values, which reaches 3.3 x 10 4 A/cm 2 at 5 K and 7 T. It is shown that co-doping with SiC and organic compound is an effective way to further improve the superconducting properties of MgB 2 .

  8. Applied Hts Bulks and Wires to Rotating Machines for Marine Propulsion

    Science.gov (United States)

    Miki, M.; Felder, B.; Kimura, Y.; Tsuzuki, K.; Taguchi, R.; Shiliang, Y.; Xu, Y.; Ida, T.; Izumi, M.

    2010-04-01

    High-temperature superconductors allow a compact and efficient way to provide high-torque density to rotating machines with excellent operation. A field pole, providing flux density of more than 1.5 T around the armature, was initially designed for an axial-gap type with the flux parallel to the rotor axis. Melt-growth Gd-123 bulks as well as Bi-2223 wire windings have been successfully assembled on the rotor disk. No iron core was used, though being an auxiliary flux control found in most HTS motors. Both bulk and wire types have realized a practical motor operation within a limited output range. For bulks, a 15 kW, 720 rpm, synchronous motor was designed and tested in the group of TUMSAT, Kitano Seiki and University of Fukui. A bulk field pole was cooled down by liquid nitrogen and was magnetized in the motor. To enhance the output power to more than 30 kW, we developed a thermosyphon system using condensed neon. Another field pole with HTS wire for large-scale marine propulsion is also discussed on a 100 kW, 230 rpm tested machine. A closed-cycle condensed neon associated with thermal insulation is also reported.

  9. Effect of cage vs. floor litter environments on the pulmonary hypertensive response to intravenous endotoxin and on blood-gas values in broilers.

    Science.gov (United States)

    Wang, W; Erf, G F; Wideman, R F

    2002-11-01

    Intravenous endotoxin has been shown to trigger a delayed pulmonary hypertensive response that varies widely in magnitude and duration among individual broilers. It was proposed that this individual variability may reflect immunological differences acquired during previous respiratory challenges that might have subsequently altered the endotoxin-initiated biochemical cascade. In Experiment 1, we tested the hypothesis that, when compared with broilers reared in clean stainless steel cages (Cage group), broilers reared on floor litter (Floor group) should experience a greater respiratory challenge and therefore may consistently exhibit a more enhanced pulmonary hypertensive response to intravenous endotoxin. Birds in the Cage group were grown in stainless steel cages at a low density (72 birds/8 m2 chamber), and fecal and dander materials were removed daily. Birds in the Floor group were reared on wood-shavings litter at a higher density (110 birds/8 m2 chamber). Pulmonary and systemic mean arterial pressures and blood-gas values were evaluated prior to and following the intravenous administration of 1 mg Salmonella typhimurium endotoxin. Broilers in the Floor and Cage groups exhibited pulmonary hypertensive responses to endotoxin that were very similar in terms of time of onset, duration, and magnitude, as well as variability in the response among individuals. Systemic hypotension also developed similarly in both groups following endotoxin injection. Blood-gas values indicated that the partial pressure of CO2 and the HCO3- concentration in arterial blood were higher (P broilers, and confirmed the negative impact of floor rearing on blood-gas values. We conclude that broilers reared on the floor inhaled litter dust and noxious fumes, which impaired pulmonary gas exchange and increased the arterial partial pressure of CO2 when compared with broilers reared in clean stainless steel cages. Nevertheless, the pulmonary hypertensive response to endotoxin did not differ

  10. Radiant Floor Cooling Systems

    DEFF Research Database (Denmark)

    Olesen, Bjarne W.

    2008-01-01

    In many countries, hydronic radiant floor systems are widely used for heating all types of buildings such as residential, churches, gymnasiums, hospitals, hangars, storage buildings, industrial buildings, and smaller offices. However, few systems are used for cooling.This article describes a floor...... cooling system that includes such considerations as thermal comfort of the occupants, which design parameters will influence the cooling capacity and how the system should be controlled. Examples of applications are presented....

  11. First-principles studies of electronic, transport and bulk properties of pyrite FeS2

    Directory of Open Access Journals (Sweden)

    Dipendra Banjara

    2018-02-01

    Full Text Available We present results from first principle, local density approximation (LDA calculations of electronic, transport, and bulk properties of iron pyrite (FeS2. Our non-relativistic computations employed the Ceperley and Alder LDA potential and the linear combination of atomic orbitals (LCAO formalism. The implementation of the LCAO formalism followed the Bagayoko, Zhao, and Williams (BZW method, as enhanced by Ekuma and Franklin (BZW-EF. We discuss the electronic energy bands, total and partial densities of states, electron effective masses, and the bulk modulus. Our calculated indirect band gap of 0.959 eV (0.96, using an experimental lattice constant of 5.4166 Å, at room temperature, is in agreement with the measured indirect values, for bulk samples, ranging from 0.84 eV to 1.03 ± 0.05 eV. Our calculated bulk modulus of 147 GPa is practically in agreement with the experimental value of 145 GPa. The calculated, partial densities of states reproduced the splitting of the Fe d bands to constitute the dominant upper most valence and lower most conduction bands, separated by the generally accepted, indirect, experimental band gap of 0.95 eV.

  12. Ab-initio investigations of the electronic properties of bulk wurtzite Beryllia and its derived nanofilms

    KAUST Repository

    Goumri-Said, Souraya

    2010-08-01

    In this Letter we investigate the electronic properties of the bulk and the nanofilm BeO in wurtzite structure. We performed a first-principles pseudo-potential method within the generalized gradient approximation. We will give more importance to the changes in band structure and density of states between the bulk structure and its derived nanofilms. The bonding characterization will be investigated via the analysis Mulliken population and charge density contours. It is found that the nanofilm retains the same properties as its bulk structure with slight changes in electronic properties and band structure which may offer some unusual transport properties. © 2010 Elsevier B.V. All rights reserved.

  13. Magnetic resonance imaging of pelvic floor dysfunction.

    Science.gov (United States)

    Lalwani, Neeraj; Moshiri, Mariam; Lee, Jean H; Bhargava, Puneet; Dighe, Manjiri K

    2013-11-01

    Pelvic floor dysfunction is largely a complex problem of multiparous and postmenopausal women and is associated with pelvic floor or organ descent. Physical examination can underestimate the extent of the dysfunction and misdiagnose the disorders. Functional magnetic resonance (MR) imaging is emerging as a promising tool to evaluate the dynamics of the pelvic floor and use for surgical triage and operative planning. This article reviews the anatomy and pathology of pelvic floor dysfunction, typical imaging findings, and the current role of functional MR imaging. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Longitudinal and bulk viscosities of Lennard-Jones fluids

    Science.gov (United States)

    Tankeshwar, K.; Pathak, K. N.; Ranganathan, S.

    1996-12-01

    Expressions for the longitudinal and bulk viscosities have been derived using Green Kubo formulae involving the time integral of the longitudinal and bulk stress autocorrelation functions. The time evolution of stress autocorrelation functions are determined using the Mori formalism and a memory function which is obtained from the Mori equation of motion. The memory function is of hyperbolic secant form and involves two parameters which are related to the microscopic sum rules of the respective autocorrelation function. We have derived expressions for the zeroth-, second-and fourth- order sum rules of the longitudinal and bulk stress autocorrelation functions. These involve static correlation functions up to four particles. The final expressions for these have been put in a form suitable for numerical calculations using low- order decoupling approximations. The numerical results have been obtained for the sum rules of longitudinal and bulk stress autocorrelation functions. These have been used to calculate the longitudinal and bulk viscosities and time evolution of the longitudinal stress autocorrelation function of the Lennard-Jones fluids over wide ranges of densities and temperatures. We have compared our results with the available computer simulation data and found reasonable agreement.

  15. Laser-induced damage of materials in bulk, thin-film, and liquid forms

    International Nuclear Information System (INIS)

    Natoli, Jean-Yves; Gallais, Laurent; Akhouayri, Hassan; Amra, Claude

    2002-01-01

    Accurate threshold curves of laser-induced damage (7-ns single shot at 1.064 μm) are measured in bulk and at the surfaces of optical components such as substrates, thin films, multilayers, and liquids. The shapes and the slopes of the curves are related to the spot size and to the densities of the nanodefects that are responsible for damage. First, these densities are reported for bulk substrates. In surfaces and films the recorded extrinsic and intrinsic threshold curves permit the discrimination of the effects of microdefects and nanodefects. In all cases the density of nanocenters is extracted by means of a phenomenological approach. Then we test liquids and mixtures of liquids with controlled defect densities. The results emphasize the agreement between measurement and prediction and demonstrate the validity of the presence of different kinds of nanocenter as the precursors of laser damage

  16. [Continuous improvement of portable domestic pelvic floor neuromuscular electrical stimulation on the pelvic floor function of patients with urinary incontinence].

    Science.gov (United States)

    Sun, Zhijing; Zhu, Lan; Lang, Jinghe; Wang, Wei; Shi, Honghui; Pang, Hongxia; Shi, Xinwen

    2015-12-01

    To evaluate continuous improvement of portable domestic pelvic floor neuromuscular electrical stimulation on the pelvic floor function of patients with stress urinary incontinence after short-term pelvic floor electrophysiological treatment in hospital. Totally 60 women with stress urinary incontinence were recruited for this randomized controlled trial. The control group including a total of 30 patients, only received 4 weeks pelvic floor electrophysiological treatment in the hospital. Family consolidation treatment group (experimental group) including 30 patients, after 4-week treatment in hospital, received 12-week of pelvic floor neuromuscular electrical stimulation using portable electrical stimulator at home under the guidance of doctors. In post-treatment 6 months and 9 months, 1-hour pad test was measured for urine leakage, pelvic floor electrical physiological parameters were assessed, and subjective improvement of symptoms of urinary incontinence were evaluated. All these data were analysed to compare the effect of the two groups. In 9 months after treatment, average change of urine leakage, the control group and experiment group were (75±24)% versus (99±3)%, the difference was statistically significant (Pcontinuous improvement of pelvic floor function.

  17. Bulk and shear viscosities of hot and dense hadron gas

    International Nuclear Information System (INIS)

    Kadam, Guru Prakash; Mishra, Hiranmaya

    2015-01-01

    We estimate the bulk and the shear viscosity at finite temperature and baryon densities of hadronic matter within a hadron resonance gas model which includes a Hagedorn spectrum. The parameters of the Hagedorn spectrum are adjusted to fit recent lattice QCD simulations at finite chemical potential. For the estimation of the bulk viscosity we use low energy theorems of QCD for the energy momentum tensor correlators. For the shear viscosity coefficient, we estimate the same using molecular kinetic theory to relate the shear viscosity coefficient to average momentum of the hadrons in the hot and dense hadron gas. The bulk viscosity to entropy ratio increases with chemical potential and is related to the reduction of velocity of sound at nonzero chemical potential. The shear viscosity to entropy ratio on the other hand, shows a nontrivial behavior with the ratio decreasing with chemical potential for small temperatures but increasing with chemical potential at high temperatures and is related to decrease of entropy density with chemical potential at high temperature due to finite volume of the hadrons

  18. Modular Flooring System

    Science.gov (United States)

    Thate, Robert

    2012-01-01

    The modular flooring system (MFS) was developed to provide a portable, modular, durable carpeting solution for NASA fs Robotics Alliance Project fs (RAP) outreach efforts. It was also designed to improve and replace a modular flooring system that was too heavy for safe use and transportation. The MFS was developed for use as the flooring for various robotics competitions that RAP utilizes to meet its mission goals. One of these competitions, the FIRST Robotics Competition (FRC), currently uses two massive rolls of broadloom carpet for the foundation of the arena in which the robots are contained during the competition. The area of the arena is approximately 30 by 72 ft (approximately 9 by 22 m). This carpet is very cumbersome and requires large-capacity vehicles, and handling equipment and personnel to transport and deploy. The broadloom carpet sustains severe abuse from the robots during a regular three-day competition, and as a result, the carpet is not used again for competition. Similarly, broadloom carpets used for trade shows at convention centers around the world are typically discarded after only one use. This innovation provides a green solution to this wasteful practice. Each of the flooring modules in the previous system weighed 44 lb (.20 kg). The improvements in the overall design of the system reduce the weight of each module by approximately 22 lb (.10 kg) (50 %), and utilize an improved "module-to-module" connection method that is superior to the previous system. The MFS comprises 4-by-4-ft (.1.2-by- 1.2-m) carpet module assemblies that utilize commercially available carpet tiles that are bonded to a lightweight substrate. The substrate surface opposite from the carpeted surface has a module-to-module connecting interface that allows for the modules to be connected, one to the other, as the modules are constructed. This connection is hidden underneath the modules, creating a smooth, co-planar flooring surface. The modules are stacked and strapped

  19. The enhancement of critical current density on the bulk of BPSCCO-system superconductor with silver additions

    International Nuclear Information System (INIS)

    Engkir Sukirman; Wisnu Ari Adi; Puji Sulisworo dan W Prasuad

    1999-01-01

    The influence of silver additions on the critical current density (Jc) of BPSCCO-bulk superconductor was investigated, with the aim of getting an increase of its Jc and trying to find out a correlation of Jc and structures of BPSCCO-silver composites. The BPSCCO-system superconductors with nominal composition Bi 1.84 Pb 0.34 Sr 2.00 Ca 2.03 Cu 3.06 O x (2223-phase) were synthesized by using solid state reaction method. The silver added was in the powder-AgO form varied from 0 to 30 wt % AgO. The critical current density, crystal structure, and micro-structure of BPSCCO-silver composites were characterized by means of four-point probe, x-ray diffractometer, and scanning electron microscope that is equipped with a link system energy dispersive spectrometer. It was found that silver additions to BPSCCO cause a reasonable improvement in Jc from 120 to 215 A/cm 2 , and a slight increase in Tc from 92 to 108 K, and lattice parameters of the 2223-phase from a 3.811(3) to 3.820(2) A, and from c = 37.08(3) to 37.15(2) A, with the optimum value occurs at 20 wt % AgO. The AgO powders added to the BPSCCO specimens were converted to Ag 2 O and metallic Ag during the annealing process at 827degC for 96 h in air. The addition of AgO to BPSCCO system does not necessarily lead to decomposition of the 2223-phase. The AgO reacts with and suppresses the 2201-phase. (author)

  20. Knowledge of the pelvic floor in nulliparous women

    OpenAIRE

    Neels, Hedwig; Wyndaele, Jean-Jacques; Tjalma, Wiebren A. A.; De Wachter, Stefan; Wyndaele, Michel; Vermandel, Alexandra

    2016-01-01

    [Purpose] Proper pelvic floor function is important to avoid serious dysfunctions including incontinence, prolapse, and sexual problems. The current study evaluated the knowledge of young nulliparous women about their pelvic floor and identified what additional information they wanted. [Subjects and Methods] In this cross-sectional survey, a validated, 36 item questionnaire was distributed to 212 nulliparous women. The questionnaire addressed demography, pelvic floor muscles, pelvic floor dys...

  1. Bulk viscosity, interaction and the viability of phantom solutions

    Energy Technology Data Exchange (ETDEWEB)

    Leyva, Yoelsy; Sepulveda, Mirko [Universidad de Tarapaca, Departamento de Fisica, Facultad de Ciencias, Arica (Chile)

    2017-06-15

    We study the dynamics of a bulk viscosity model in the Eckart approach for a spatially flat Friedmann-Robertson-Walker (FRW) Universe. We have included radiation and dark energy, assumed as perfect fluids, and dark matter treated as an imperfect fluid having bulk viscosity. We also introduce an interaction term between the dark matter and dark energy components. Considering that the bulk viscosity is proportional to the dark matter energy density and imposing a complete cosmological dynamics, we find bounds on the bulk viscosity in order to reproduce a matter-dominated era (MDE). This constraint is independent of the interaction term. Some late time phantom solutions are mathematically possible. However, the constraint imposed by a MDE restricts the interaction parameter, in the phantom solutions, to a region consistent with a null value, eliminating the possibility of late time stable solutions with w < -1. From the different cases that we study, the only possible scenario, with bulk viscosity and interaction term, belongs to the quintessence region. In the latter case, we find bounds on the interaction parameter compatible with latest observational data. (orig.)

  2. Mixed-state flux dynamics in bulk MgB2

    International Nuclear Information System (INIS)

    Li Shi; Taylor, B.J.; Frederick, N.A.; Maple, M.B.; Nesterenko, V.F.; Indrakanti, S.S.

    2002-01-01

    Electric field vs. current density (E-J) isotherms in the mixed-state of a bulk sample of the high-temperature superconductor MgB 2 (T c =38.5 K), synthesized under 200 MPa pressure by hot isostatic pressing (HIPing), have been measured and analyzed in terms of the critical scaling model. Magnetization data reveal distinctly different critical current density (J c ) behaviors in high and low magnetic field critical scaling regions. E-J isotherm sets at fields ranging from 2 to 90 kOe conform to the vortex-glass (VG) scaling anzatz. Scaling analysis, resistivity data and J c data suggest that a Bragg-glass state may exist for H c2 (T), the VG transition line H g (T), and the magnetic irreversibility line H irr (T) has been established for bulk MgB 2

  3. Container floor at high temperatures

    International Nuclear Information System (INIS)

    Reutler, H.; Klapperich, H.J.; Mueller-Frank, U.

    1978-01-01

    The invention describes a floor for container which is stressed at high, changing temperatures and is intended for use in gas-cooled nuclear reactors. Due to the downward cooling gas flow in these types of reactor, the reactor floor is subjected to considerable dimensional changes during switching on and off. In the heating stage, the whole graphite structure of the reactor core and floor expands. In order to avoid arising constraining forces, sufficiently large expansion spaces must be allowed for furthermore restoring forces must be present to close the gaps again in the cooling phase. These restoring forces must be permanently present to prevent loosening of the core cuits amongst one another and thus uncontrollable relative movement. Spring elements are not suitable due to fast fatigue as a result of high temperatures and radiation exposure. It is suggested to have the floor elements supported on rollers whose rolling planes are downwards inclined to a fixed point for support. The construction is described in detail by means of drawings. (GL) [de

  4. No bulging of floor heating pipes to be expected in case of incomplete floor plastering

    Energy Technology Data Exchange (ETDEWEB)

    Radtke, U

    1983-02-01

    According to advertising slogans floor heating pipes are said to be damaged prematurely by bulges if they are not completely surrounded by flooring plaster. The author has thoroughly dealt with this problem and made the respective measurements. He found out that there are so few bulges occurring that they cannot lead to damages.

  5. Contamination of YBCO bulk superconductors by samarium and ytterbium

    Czech Academy of Sciences Publication Activity Database

    Volochová, D.; Jurek, Karel; Radušovská, M.; Piovarči, S.; Antal, V.; Kováč, J.; Jirsa, Miloš; Diko, P.

    2014-01-01

    Roč. 496, JAN (2014), s. 14-17 ISSN 0921-4534 Institutional support: RVO:68378271 Keywords : YBCO bulk superconductors * critical temperature * critical current density * peak effect Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 0.942, year: 2014

  6. Technical Note: Is bulk electron density assignment appropriate for MRI-only based treatment planning for lung cancer?

    Science.gov (United States)

    Prior, Phil; Chen, Xinfeng; Gore, Elizabeth; Johnstone, Candice; Li, X Allen

    2017-07-01

    MRI-based treatment planning in radiation therapy (RT) is prohibitive, in part, due to the lack of electron density (ED) information within the image. The dosimetric differences between MRI- and CT-based planning for intensity modulated RT (IMRT) of lung cancer were investigated to assess the appropriateness of bulk ED assignment. Planning CTs acquired for six representative lung cancer patients were used to generate bulk ED IMRT plans. To avoid the effect of anatomic differences between CT and MRI, "simulated MRI-based plans" were generated by forcing the relative ED (rED) to water on CT-delineated structures using organ specific values from the ICRU Report 46 and using the mean rED value of the internal target volume (ITV) from the planning CT. The "simulated MRI-based plans" were generated using a research planning system (Monaco v5.09.07a, Elekta, AB) and employing Monte Carlo dose calculation. The following dose-volume-parameters (DVPs) were collected from both the "simulated MRI-based plans" and the original planning CT: D 95 , the dose delivered to 95% of the ITV & planning target volume (PTV), D 5 and V 5 , the volume of normal lung irradiated ≥5 Gy. The percent point difference and relative dose difference were used for comparison with the CT based plan for V 5 and D 95 respectively. A total of five plans per patient were generated; three with the ITV rED (rED ITV ) = 1.06, 1.0 and the mean value from the planning CT while the lung rED (rED lung ) was fixed at the ICRU value of 0.26 and two with rED lung = 0.1 and 0.5 while the rED ITV was fixed to the mean value from the planning CT. Noticeable differences in the ITV and PTV DVPs were observed. Variations of the normal lung V 5 can be as large as 9.6%. In some instances, varying the rED ITV between rED mean and 1.06 resulted in D 95 increases ranging from 3.9% to 6.3%. Bulk rED assignment on normal lung affected the DVPs of the ITV and PTV by 4.0-9.8% and 0.3-19.6% respectively. Dose volume histograms

  7. Recognition and Management of Nonrelaxing Pelvic Floor Dysfunction

    OpenAIRE

    Faubion, Stephanie S.; Shuster, Lynne T.; Bharucha, Adil E.

    2012-01-01

    Nonrelaxing pelvic floor dysfunction is not widely recognized. Unlike in pelvic floor disorders caused by relaxed muscles (eg, pelvic organ prolapse or urinary incontinence, both of which often are identified readily), women affected by nonrelaxing pelvic floor dysfunction may present with a broad range of nonspecific symptoms. These may include pain and problems with defecation, urination, and sexual function, which require relaxation and coordination of pelvic floor muscles and urinary and ...

  8. Floor-Fractured Craters through Machine Learning Methods

    Science.gov (United States)

    Thorey, C.

    2015-12-01

    Floor-fractured craters are impact craters that have undergone post impact deformations. They are characterized by shallow floors with a plate-like or convex appearance, wide floor moats, and radial, concentric, and polygonal floor-fractures. While the origin of these deformations has long been debated, it is now generally accepted that they are the result of the emplacement of shallow magmatic intrusions below their floor. These craters thus constitute an efficient tool to probe the importance of intrusive magmatism from the lunar surface. The most recent catalog of lunar-floor fractured craters references about 200 of them, mainly located around the lunar maria Herein, we will discuss the possibility of using machine learning algorithms to try to detect new floor-fractured craters on the Moon among the 60000 craters referenced in the most recent catalogs. In particular, we will use the gravity field provided by the Gravity Recovery and Interior Laboratory (GRAIL) mission, and the topographic dataset obtained from the Lunar Orbiter Laser Altimeter (LOLA) instrument to design a set of representative features for each crater. We will then discuss the possibility to design a binary supervised classifier, based on these features, to discriminate between the presence or absence of crater-centered intrusion below a specific crater. First predictions from different classifier in terms of their accuracy and uncertainty will be presented.

  9. Development of superconductor bulk for superconductor bearing

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chan Joong; Jun, Byung Hyuk; Park, Soon Dong (and others)

    2008-08-15

    Current carrying capacity is one of the most important issues in the consideration of superconductor bulk materials for engineering applications. There are numerous applications of Y-Ba-Cu-O (YBCO) bulk superconductors e.g. magnetic levitation train, flywheel energy storage system, levitation transportation, lunar telescope, centrifugal device, magnetic shielding materials, bulk magnets etc. Accordingly, to obtain YBCO materials in the form of large, single crystals without weak-link problem is necessary. A top seeded melt growth (TSMG) process was used to fabricate single crystal YBCO bulk superconductors. The seeded and infiltration growth (IG) technique was also very promising method for the synthesis of large, single-grain YBCO bulk superconductors with good superconducting properties. 5 wt.% Ag doped Y211 green compacts were sintered at 900 .deg. C {approx} 1200 .deg.C and then a single crystal YBCO was fabricated by an infiltration method. A refinement and uniform distribution of the Y211 particles in the Y123 matrix were achieved by sintering the Ag-doped samples. This enhancement of the critical current density was ascribable to a fine dispersion of the Y211 particles, a low porosity and the presence of Ag particles. In addition, we have designed and manufactured large YBCO single domain with levitation force of 10-13 kg/cm{sup 2} using TSMG processing technique.

  10. Materials processing and machine applications of bulk HTS

    Science.gov (United States)

    Miki, M.; Felder, B.; Tsuzuki, K.; Xu, Y.; Deng, Z.; Izumi, M.; Hayakawa, H.; Morita, M.; Teshima, H.

    2010-12-01

    We report a refrigeration system for rotating machines associated with the enhancement of the trapped magnetic flux of bulk high-temperature superconductor (HTS) field poles. A novel cryogenic system was designed and fabricated. It is composed of a low-loss rotary joint connecting the rotor and a closed-cycle thermosiphon under a GM cryocooler using a refrigerant. Condensed neon gas was adopted as a suitable cryogen for the operation of HTS rotating machines with field poles composed of RE-Ba-Cu-O family materials, where RE is a rare-earth metal. Regarding the materials processing of the bulks HTS, thanks to the addition of magnetic particles to GdBa2Cu3O7 - d (Gd123) bulk superconductors an increase of more than 20% in the trapped magnetic flux density was achieved at liquid nitrogen temperature. Field-pole Gd123 bulks up to 46 mm in diameter were synthesized with the addition of Fe-B alloy magnetic particles and assembled into the synchronous machine rotor to be tested. Successful cooling of the magnetized rotor field poles down to 35 K and low-output-power rotating operation was achieved up to 720 rpm in the test machine with eight field-pole bulks. The present results show a substantial basis for making a prototype system of rotating machinery of applied HTS bulks.

  11. Materials processing and machine applications of bulk HTS

    Energy Technology Data Exchange (ETDEWEB)

    Miki, M; Felder, B; Tsuzuki, K; Xu, Y; Deng, Z; Izumi, M [Department of Marine Electronics and Mechanical Engineering, Tokyo University of Marine Science and Technology, 2-1-6, Etchu-jima, Koto-ku, Tokyo 135-8533 (Japan); Hayakawa, H [Kitano Seiki Co. Ltd, 7-17-3, Chuo, Ohta-ku, Tokyo 143-0024 (Japan); Morita, M; Teshima, H, E-mail: d082025@kaiyodai.ac.j [Nippon Steel Co. Ltd, 20-1, Shintomi, Huttsu-shi, Chiba 293-8511 (Japan)

    2010-12-15

    We report a refrigeration system for rotating machines associated with the enhancement of the trapped magnetic flux of bulk high-temperature superconductor (HTS) field poles. A novel cryogenic system was designed and fabricated. It is composed of a low-loss rotary joint connecting the rotor and a closed-cycle thermosiphon under a GM cryocooler using a refrigerant. Condensed neon gas was adopted as a suitable cryogen for the operation of HTS rotating machines with field poles composed of RE-Ba-Cu-O family materials, where RE is a rare-earth metal. Regarding the materials processing of the bulks HTS, thanks to the addition of magnetic particles to GdBa{sub 2}Cu{sub 3}O{sub 7-d} (Gd123) bulk superconductors an increase of more than 20% in the trapped magnetic flux density was achieved at liquid nitrogen temperature. Field-pole Gd123 bulks up to 46 mm in diameter were synthesized with the addition of Fe-B alloy magnetic particles and assembled into the synchronous machine rotor to be tested. Successful cooling of the magnetized rotor field poles down to 35 K and low-output-power rotating operation was achieved up to 720 rpm in the test machine with eight field-pole bulks. The present results show a substantial basis for making a prototype system of rotating machinery of applied HTS bulks.

  12. Comparison of panoramic radiograph with cone-beam computed tomography in assessment of maxillary sinus floor and nasal floor

    Directory of Open Access Journals (Sweden)

    Vijay Kumar Bokkasam

    2015-01-01

    Full Text Available Introduction: Panoramic radiograph is frequently prescribed by dentists for implant planning and, hence, accurate assessment of anatomical structures in panoramic radiograph is of utmost importance. Aims: The aim of the present study is to know the accuracy of panoramic radiograph in assessment of relationship between maxillary sinus floor and posterior teeth roots, and the distance from alveolar crest to nasal floor by comparing it with that of cone-beam computed tomographic (CBCT image. Materials and Methods: Panoramic and CBCT images of 30 patients were analyzed. The topographic relationship of each root of posterior teeth to the maxillary sinus floor was evaluated and classified into three classes. The distance from the peak point on maxillary alveolar crest to nasal floor was measured in panoramic radiograph as well as in CBCT image. All the measurements were made by built-in measurement tools. Results: Class 1 roots in panoramic radiograph showed high agreement (86% with CBCT image, followed by class 0 (76%. There was a significant difference in the measurements of alveolar bone height (ABH in the nasal floor region with a P value of 0.018. Conclusion: Panoramic radiograph is reliable in assessment of nasal floor and maxillary sinus, provided position of the patient, distortion, and the inherent magnification factor are taken into consideration.

  13. Imaging pelvic floor disorders. 2. rev. ed.

    International Nuclear Information System (INIS)

    Stoker, Jaap; Taylor, Stuart A.; DeLancey, John O.L.

    2008-01-01

    This volume builds on the success of the first edition of imaging pelvic floor disorders and is aimed at those practitioners with an interest in the imaging, diagnosis and treatment of pelvic floor dysfunction. Concise textual information from acknowledged experts is complemented by high-quality diagrams and images to provide a thorough update of this rapidly evolving field. Introductory chapters fully elucidate the anatomical basis underlying disorders of the pelvic floor. State of the art imaging techniques and their application in pelvic floor dysfunction are then discussed in detail. Additions since the first edition include consideration of the effect of aging and new chapters on perineal ultrasound, functional MRI and MRI of the levator muscles. The closing sections of the book describe the modern clinical management of pelvic floor dysfunction, including prolapse, urinary and faecal incontinence and constipation, with specific emphasis on the integration of diagnostic and treatment algorithms. (orig.)

  14. Imaging pelvic floor disorders. 2. rev. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Stoker, Jaap [Amsterdam Univ. (Netherlands). Dept. of Radiology; Taylor, Stuart A. [University College Hospital, London (United Kingdom). Dept. of Specialist X-Ray; DeLancey, John O.L. (eds.) [Michigan Univ., Ann Arbor, MI (United States). L4000 Women' s Hospital

    2008-07-01

    This volume builds on the success of the first edition of imaging pelvic floor disorders and is aimed at those practitioners with an interest in the imaging, diagnosis and treatment of pelvic floor dysfunction. Concise textual information from acknowledged experts is complemented by high-quality diagrams and images to provide a thorough update of this rapidly evolving field. Introductory chapters fully elucidate the anatomical basis underlying disorders of the pelvic floor. State of the art imaging techniques and their application in pelvic floor dysfunction are then discussed in detail. Additions since the first edition include consideration of the effect of aging and new chapters on perineal ultrasound, functional MRI and MRI of the levator muscles. The closing sections of the book describe the modern clinical management of pelvic floor dysfunction, including prolapse, urinary and faecal incontinence and constipation, with specific emphasis on the integration of diagnostic and treatment algorithms. (orig.)

  15. Floor heating maximizes residents` comfort

    Energy Technology Data Exchange (ETDEWEB)

    Tirkkanen, P.; Wikstroem, T.

    1996-11-01

    Storing heat in floors by using economical night-time electricity does not increase the specific consumption of heating. According to studies done by IVO, the optimum housing comfort is achieved if the room is heated mainly by means of floor heating that is evened out by window or ceiling heating, or by a combination of all three forms of heating. (orig.)

  16. Large-scale HTS bulks for magnetic application

    International Nuclear Information System (INIS)

    Werfel, Frank N.; Floegel-Delor, Uta; Riedel, Thomas; Goebel, Bernd; Rothfeld, Rolf; Schirrmeister, Peter; Wippich, Dieter

    2013-01-01

    Highlights: ► ATZ Company has constructed about 130 HTS magnet systems. ► Multi-seeded YBCO bulks joint the way for large-scale application. ► Levitation platforms demonstrate “superconductivity” to a great public audience (100 years anniversary). ► HTS magnetic bearings show forces up to 1 t. ► Modular HTS maglev vacuum cryostats are tested for train demonstrators in Brazil, China and Germany. -- Abstract: ATZ Company has constructed about 130 HTS magnet systems using high-Tc bulk magnets. A key feature in scaling-up is the fabrication of YBCO melts textured multi-seeded large bulks with three to eight seeds. Except of levitation, magnetization, trapped field and hysteresis, we review system engineering parameters of HTS magnetic linear and rotational bearings like compactness, cryogenics, power density, efficiency and robust construction. We examine mobile compact YBCO bulk magnet platforms cooled with LN 2 and Stirling cryo-cooler for demonstrator use. Compact cryostats for Maglev train operation contain 24 pieces of 3-seed bulks and can levitate 2500–3000 N at 10 mm above a permanent magnet (PM) track. The effective magnetic distance of the thermally insulated bulks is 2 mm only; the stored 2.5 l LN 2 allows more than 24 h operation without refilling. 34 HTS Maglev vacuum cryostats are manufactured tested and operate in Germany, China and Brazil. The magnetic levitation load to weight ratio is more than 15, and by group assembling the HTS cryostats under vehicles up to 5 t total loads levitated above a magnetic track is achieved

  17. Large-scale HTS bulks for magnetic application

    Energy Technology Data Exchange (ETDEWEB)

    Werfel, Frank N., E-mail: werfel@t-online.de [Adelwitz Technologiezentrum GmbH (ATZ), Rittergut Adelwitz 16, 04886 Arzberg-Adelwitz (Germany); Floegel-Delor, Uta; Riedel, Thomas; Goebel, Bernd; Rothfeld, Rolf; Schirrmeister, Peter; Wippich, Dieter [Adelwitz Technologiezentrum GmbH (ATZ), Rittergut Adelwitz 16, 04886 Arzberg-Adelwitz (Germany)

    2013-01-15

    Highlights: ► ATZ Company has constructed about 130 HTS magnet systems. ► Multi-seeded YBCO bulks joint the way for large-scale application. ► Levitation platforms demonstrate “superconductivity” to a great public audience (100 years anniversary). ► HTS magnetic bearings show forces up to 1 t. ► Modular HTS maglev vacuum cryostats are tested for train demonstrators in Brazil, China and Germany. -- Abstract: ATZ Company has constructed about 130 HTS magnet systems using high-Tc bulk magnets. A key feature in scaling-up is the fabrication of YBCO melts textured multi-seeded large bulks with three to eight seeds. Except of levitation, magnetization, trapped field and hysteresis, we review system engineering parameters of HTS magnetic linear and rotational bearings like compactness, cryogenics, power density, efficiency and robust construction. We examine mobile compact YBCO bulk magnet platforms cooled with LN{sub 2} and Stirling cryo-cooler for demonstrator use. Compact cryostats for Maglev train operation contain 24 pieces of 3-seed bulks and can levitate 2500–3000 N at 10 mm above a permanent magnet (PM) track. The effective magnetic distance of the thermally insulated bulks is 2 mm only; the stored 2.5 l LN{sub 2} allows more than 24 h operation without refilling. 34 HTS Maglev vacuum cryostats are manufactured tested and operate in Germany, China and Brazil. The magnetic levitation load to weight ratio is more than 15, and by group assembling the HTS cryostats under vehicles up to 5 t total loads levitated above a magnetic track is achieved.

  18. 78 FR 30329 - Multilayered Wood Flooring from China

    Science.gov (United States)

    2013-05-22

    ...)] Multilayered Wood Flooring from China AGENCY: United States International Trade Commission. ACTION: Notice of...-1179 (Final) concerning multilayered wood flooring (``MLWF'') from China. For further information... reconsider ``its decision not to investigate domestic producers of hardwood plywood used for flooring'' 2. to...

  19. Pelvic floor function during and after first pregnancy

    NARCIS (Netherlands)

    Brummen, H.J. van

    2006-01-01

    This study evaluated the effects the first pregnancy and childbirth on the pelvic floor. Pregnancy and vaginal delivery can negatively affect pelvic floor function. Micturition symptoms, defecation symptoms and sexual dysfunction are all signs of an impaired pelvic floor function. These symptoms are

  20. Gait of dairy cows on floors with different slipperiness.

    Science.gov (United States)

    Telezhenko, E; Magnusson, M; Bergsten, C

    2017-08-01

    This study assessed the slip resistance of different types of solid flooring in cattle housing using a range of technical tests and gait analysis. Dynamic and static coefficient of friction, skid resistance, and abrasiveness were tested on concrete flooring with a smooth finish, a grooved pattern, or a tamped pattern, acid-resistant mastic asphalt, soft rubber mats, and a worn slatted concrete floor. Coefficients of friction and skid resistance were tested under clean and slurry-soiled conditions. Linear kinematic variables were assessed in 40 cows with trackway measurements after the cows passed over the floors in a straight walk. All gait variables were assessed as deviations from those obtained on the slatted concrete floor, which was used as a baseline. The coefficient of friction tests divided the floors into 3 categories: concrete flooring, which had a low coefficient of friction (0.29-0.41); mastic asphalt flooring, which had medium values (0.38-0.45); and rubber mats, which had high values (0.49-0.57). The highest abrasion (g/10 m) was on the asphalt flooring (4.48), and the concrete flooring with a tamped pattern had significantly higher abrasiveness (2.77) than the other concrete floors (1.26-1.60). Lowest values on the skid-resistance tests (dry/wet) were for smooth concrete (79/35) and mastic asphalt (65/47), especially with a slurry layer on the surface. Gait analysis mainly differentiated floors with higher friction and abrasion by longer strides and better tracking. Step asymmetry was lower on floors with high skid-resistance values. The most secure cow gait, in almost every aspect, was observed on soft rubber mats. Relationships between gait variables and physical floor characteristics ranged from average to weak (partial correlations 0.54-0.16). Thus, none of the physical characteristics alone was informative enough to characterize slip resistance. With reference to gait analysis, the abrasiveness of the hard surfaces was more informative than the

  1. Mapping of multi-floor buildings: A barometric approach

    DEFF Research Database (Denmark)

    Özkil, Ali Gürcan; Fan, Zhun; Xiao, Jizhong

    2011-01-01

    This paper presents a new method for mapping multi5floor buildings. The method combines laser range sensor for metric mapping and barometric pressure sensor for detecting floor transitions and map segmentation. We exploit the fact that the barometric pressure is a function of the elevation......, and it varies between different floors. The method is tested with a real robot in a typical indoor environment, and the results show that physically consistent multi5floor representations are achievable....

  2. Some Passive Damping Sources on Flooring Systems besides the TMD

    DEFF Research Database (Denmark)

    Pedersen, Lars

    2010-01-01

    Impulsive loads and walking loads can generate problematic structural vibrations in flooring-systems. Measures that may be taken to mitigate the problem would often be to consider the implementation of a tuned mass damper or even more advanced vibration control technologies; this in order to add...... damping to the structure. Basically also passive humans on a floor act as a damping source, but it also turns out from doing system identification tests with a floor strip that a quite simple set-up installed on the floor (cheap and readily at hand) might do a good job in terms of reducing vertical floor...... vibrations for some floors. The paper describes the tests with the floor strip, and the results, in terms of dynamic floor behaviour, are compared with what would be expected had the floor instead been equipped with a tuned mass damper....

  3. Reliability of AlGaN/GaN high electron mobility transistors on low dislocation density bulk GaN substrate: Implications of surface step edges

    Energy Technology Data Exchange (ETDEWEB)

    Killat, N., E-mail: Nicole.Killat@bristol.ac.uk, E-mail: Martin.Kuball@bristol.ac.uk; Montes Bajo, M.; Kuball, M., E-mail: Nicole.Killat@bristol.ac.uk, E-mail: Martin.Kuball@bristol.ac.uk [Center for Device Thermography and Reliability (CDTR), H.H. Wills Physics Laboratory, Tyndall Avenue, Bristol BS8 1TL (United Kingdom); Paskova, T. [Kyma Technologies, Inc., Raleigh, North Carolina 27617 (United States); Materials Science and Engineering Department, North Carolina State University, Raleigh, North Carolina 27695 (United States); Evans, K. R. [Kyma Technologies, Inc., Raleigh, North Carolina 27617 (United States); Leach, J. [Kyma Technologies, Inc., Raleigh, North Carolina 27617 (United States); Electrical and Computer Engineering Department, Virginia Commonwealth University, Richmond, Virginia 23284 (United States); Li, X.; Özgür, Ü.; Morkoç, H. [Electrical and Computer Engineering Department, Virginia Commonwealth University, Richmond, Virginia 23284 (United States); Chabak, K. D.; Crespo, A.; Gillespie, J. K.; Fitch, R.; Kossler, M.; Walker, D. E.; Trejo, M.; Via, G. D.; Blevins, J. D. [Air Force Research Laboratory, Wright-Patterson Air Force Base, Dayton, Ohio 45433 (United States)

    2013-11-04

    To enable gaining insight into degradation mechanisms of AlGaN/GaN high electron mobility transistors, devices grown on a low-dislocation-density bulk-GaN substrate were studied. Gate leakage current and electroluminescence (EL) monitoring revealed a progressive appearance of EL spots during off-state stress which signify the generation of gate current leakage paths. Atomic force microscopy evidenced the formation of semiconductor surface pits at the failure location, which corresponds to the interaction region of the gate contact edge and the edges of surface steps.

  4. Life cycle inventory of manufacturing prefinished engineered wood flooring in eastern U.S. with comparison to solid strip wood flooring

    Science.gov (United States)

    Richard D. Bergman; Scott A. Bowe

    2011-01-01

    Building products have come under increased scrutiny because of environmental impacts from their manufacture. Our study followed the life cycle inventory approach for prefinished engineered wood flooring in the eastern US and compared the results with those of solid strip wood flooring. Our study surveyed five engineered wood flooring manufacturers in the eastern US....

  5. Experimental Verification of an Instrument to Test Flooring Materials

    Science.gov (United States)

    Philip, Rony; Löfgren, Hans, Dr

    2018-02-01

    The focus of this work is to validate the fluid model with different flooring materials and the measurements of an instrument to test flooring materials and its force attenuating capabilities using mathematical models to describe the signature and coefficients of the floor. The main contribution of the present work focus on the development of a mathematical fluid model for floors. The aim of the thesis was to analyze, compare different floor materials and to study the linear dynamics of falling impacts on floors. The impact of the hammer during a fall is captured by an accelerometer and response is collected using a picoscope. The collected data was analyzed using matlab least square method which is coded as per the fluid model. The finding from this thesis showed that the fluid model works with more elastic model but it doesn’t work for rigid materials like wood. The importance of parameters like velocity, mass, energy loss and other coefficients of floor which influences the model during the impact of falling on floors were identified and a standardized testing method was set.

  6. Patients with Pelvic Floor Muscle Spasm Have a Superior Response to Pelvic Floor Physical Therapy at Specialized Centers.

    Science.gov (United States)

    Polackwich, Alan Scott; Li, Jianbo; Shoskes, Daniel A

    2015-10-01

    Chronic prostatitis/chronic pelvic pain syndrome is a common condition that often requires multimodal therapy. Patients with chronic pelvic pain syndrome have a high incidence of pelvic floor spasm, which can be treated with pelvic floor physical therapy. However, this is a specialized skill. We compared outcomes of pelvic floor physical therapy as part of multimodal therapy in patients with chronic pelvic pain syndrome between those treated at our institution and elsewhere. We identified patients from our chronic pelvic pain syndrome registry with pelvic floor spasm who were seen between 2010 and 2014 for more than 1 visit. Patient phenotype was assessed with the UPOINT system and symptom severity was determined by the National Institutes of Health CPSI. A 6-point decrease in CPSI was used to define patient improvement. A total of 82 patients fit the study criteria. Mean age was 41.6 years (range 19 to 75) and median symptom duration was 24 months (range 3 to 240). Mean CPSI was 26.8 (range 10 to 41), the median number of positive UPOINT domains was 3 (range 1 to 6) and 27 patients (32.9%) were treated locally. At followup 9 patients had refused pelvic floor physical therapy, and 24 and 48 had undergone pelvic floor physical therapy elsewhere and at CCF, respectively. The mean change in CPSI was 1.11 ± 4.1 in patients who refused, -3.46 ± 6.7 in those treated elsewhere and -11.3 ± 7.0 in those treated at CCF (p physical therapy at CCF (OR 4.23, p = 0.002) and symptom duration (OR 0.52, p = 0.03) predicted improvement. Pelvic floor physical therapy can be effective for chronic pelvic pain syndrome in patients with pelvic floor spasm. However, the outcome depends on specialty training and experience of therapists. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  7. Investigation of Floor Surface Finishes for Optimal Slip Resistance Performance

    Directory of Open Access Journals (Sweden)

    In-Ju Kim

    2018-03-01

    Full Text Available Background: Increasing the slip resistance of floor surfaces would be desirable, but there is a lack of evidence on whether traction properties are linearly correlated with the topographic features of the floor surfaces or what scales of surface roughness are required to effectively control the slipperiness of floors. Objective: This study expands on earlier findings on the effects of floor surface finishes against slip resistance performance and determines the operative ranges of floor surface roughness for optimal slip resistance controls under different risk levels of walking environments. Methods: Dynamic friction tests were conducted among three shoes and nine floor specimens under wet and oily environments and compared with a soapy environment. Results: The test results showed the significant effects of floor surface roughness on slip resistance performance against all the lubricated environments. Compared with the floor-type effect, the shoe-type effect on slip resistance performance was insignificant against the highly polluted environments. The study outcomes also indicated that the oily environment required rougher surface finishes than the wet and soapy ones in their lower boundary ranges of floor surface roughness. Conclusion: The results of this study with previous findings confirm that floor surface finishes require different levels of surface coarseness for different types of environmental conditions to effectively manage slippery walking environments. Collected data on operative ranges of floor surface roughness seem to be a valuable tool to develop practical design information and standards for floor surface finishes to efficiently prevent pedestrian fall incidents. Keywords: floor surface finishes, operational levels of floor surface roughness, slip resistance, wet, soapy and oily environments

  8. An architecture for agile shop floor control systems

    DEFF Research Database (Denmark)

    Langer, Gilad; Alting, Leo

    2000-01-01

    as shop floor control. This paper presents the Holonic Multi-cell Control System (HoMuCS) architecture that allows for design and development of holonic shop floor control systems. The HoMuCS is a shop floor control system which is sometimes referred to as a manufacturing execution system...

  9. Comfort analysis of lightweight floor system

    NARCIS (Netherlands)

    Zegers, S.F.A.J.G.; Herwijnen, van F.; Randall, B.

    2007-01-01

    During the past 60 years, floor systems used in housing and office-buildings in the Netherlands were mostly made of concrete or other similar materials, These floor systems, which can be characterized as heavy, normally posed little problems concerning vibrations. In recent years, in light of

  10. Floor Vibrations - as Induced and Reduced by Humans

    DEFF Research Database (Denmark)

    Pedersen, Lars

    . As for dynamic loads focus is placed on heel impact excitation and actions of jumping people causing floor vibrations. As for interaction between stationary humans and the vibrating floor focus is on modelling humans as oscillating spring-mass-damper systems attached to the floor rather than as simple added mass...

  11. Nuclear Matter Bulk Parameter Scales and Correlations

    International Nuclear Information System (INIS)

    Santos, B. M.; Delfino, A.; Dutra, M.; Lourenço, O.

    2015-01-01

    We study the arising of correlations among some isovector bulk parameters in nonrelativistic and relativistic hadronic mean-field models. For the former, we investigate correlations in the nonrelativistic (NR) limit of relativistic point-coupling models. We provide analytical correlations, for the NR limit model, between the symmetry energy and its derivatives, namely, the symmetry energy slope, curvature, skewness and fourth order derivative, discussing the conditions in which they are linear ones. We also show that some correlations presented in the NR limit model are reproduced for relativistic models presenting cubic and quartic self-interactions in its scalar field. As a direct application of such linear correlations, we remark its association with possible crossing points in the density dependence of the linearly correlated bulk parameter. (author)

  12. Flooring-systems and their interaction with furniture and humans

    DEFF Research Database (Denmark)

    Frier, Christian; Pedersen, Lars; Andersen, Lars Vabbersgaard

    2017-01-01

    Flooring-system designs may be sensitive in terms of their vibrational performance due the risk that serviceability-limit-state problems may be encountered. For evaluating the vibrational performance of a flooring system at the design stage, decisions must be made by the engineer in charge...... of computations. Passive humans and/or furniture are often present on a floor. Typically, these masses and their way of interacting with the floor mass are ignored in predictions of vibrational behaviour of the flooring system. Utilizing a shell finite-element model, the paper explores and quantifies how non......-structural mass can influence central parameters describing the dynamic behaviour of the flooring system with focus on elevated non-structural mass. © 2017 The Authors. Published by Elsevier Ltd....

  13. Development of floor design response spectra for seismic design of floor-supported equipment or components, Revision 1, February 1978

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    This guide presents an acceptable method for developing two horizontal and one vertical floor design response spectra at various floor or other equipment-support locations from the time-history motions resulting from the dynamic analysis of the supporting structure. These floor design response spectra are used in the dynamic analysis of systems or equipment supported at various locations of the supporting structure. Consulation has been provided by the Advisory Committee on Reactor Safeguards

  14. Deflection of resilient materials for reduction of floor impact sound.

    Science.gov (United States)

    Lee, Jung-Yoon; Kim, Jong-Mun

    2014-01-01

    Recently, many residents living in apartment buildings in Korea have been bothered by noise coming from the houses above. In order to reduce noise pollution, communities are increasingly imposing bylaws, including the limitation of floor impact sound, minimum thickness of floors, and floor soundproofing solutions. This research effort focused specifically on the deflection of resilient materials in the floor sound insulation systems of apartment houses. The experimental program involved conducting twenty-seven material tests and ten sound insulation floating concrete floor specimens. Two main parameters were considered in the experimental investigation: the seven types of resilient materials and the location of the loading point. The structural behavior of sound insulation floor floating was predicted using the Winkler method. The experimental and analytical results indicated that the cracking strength of the floating concrete floor significantly increased with increasing the tangent modulus of resilient material. The deflection of the floating concrete floor loaded at the side of the specimen was much greater than that of the floating concrete floor loaded at the center of the specimen. The Winkler model considering the effect of modulus of resilient materials was able to accurately predict the cracking strength of the floating concrete floor.

  15. Decontamination of polyvinylchloride- and rubber type flooring

    International Nuclear Information System (INIS)

    Kunze, S.

    1975-01-01

    These types, fabricated by mixing of the basic components, showed no relation between content of fillers and decontamination results. Decontamination results are partly poorer, if the flooring contains a high concentration of the filler, especially if the latter consists mainly of hydrophilic materials. The coloring of the floorings seems to have no influence on the decontamination but floorings with clearly separated patterns can not be recommended for nuclear facilities. Fabricated by chemical reactions between polymeres, vulcanization materials and fillers, the decontamination results depend definitely from the proper choice of the filler. Flooring types, containing lampblack, graphite, kaoline, barium sulfate and titanium oxide are easy to decontamine. Again, increasing contents of hydrophilic filler cause a fall off in the decontamination results. (orig.) [de

  16. The microstructure of MX-80 clay with respect to its bulk physical properties under different environmental conditions

    International Nuclear Information System (INIS)

    Pusch, R.

    2001-03-01

    A model of microstructural evolution of MX-80 buffer is presented in the report.Quantification of the microstructure is made by use of digitalized micrographs taken by transmission electron microscopy using suitably impregnated specimens with appropriate thickness. The model is termed MMM, a successor of the earlier GMM. Practically useful microstructural parameters refer to the fraction of a thin section that represents dense and soft parts of the clay matrix. The derived microstructural parameters are directly coupled to the most important bulk physical properties, i.e. the hydraulic conductivity, gas penetrability, swelling pressure and cation/anion diffusion capacities. The study has shown that even at very high densities, softer and more pervious zones exist in the form of interconnected 'external' voids filled with more or less dense clay gels. At bulk densities exceeding 2000 kg/m 3 after water saturation, the gel density is also high but for low bulk densities it may be so much reduced that the gels do not remain stable at high electrolyte content of the pore water. The fact that the density variations are small for high bulk densities means that the separation of matrix components ('fracturing') that is required for letting gas through is on the same order of magnitude as the bulk swelling pressure. For lower bulk densities, displacement or consolidation of the clay gels in 'external' voids is concluded to take place in conjunction with gas penetration. At high densities the limited degree of continuity and constrictions of the channels leading to anion-excluding charge conditions mean that the anion diffusion capacity is very low, while cation diffusion may be extensive because it takes place not only through channels but also through the inter lamellar space and along the surfaces of stacks of lamellae, i.e. by surface diffusion. Two Pre-Quaternary clays that have been investigated and characterized with respect to the microstructure represent two

  17. The microstructure of MX-80 clay with respect to its bulk physical properties under different environmental conditions

    Energy Technology Data Exchange (ETDEWEB)

    Pusch, R. [Geodevelopment AB, Lund (Sweden)

    2001-03-01

    A model of microstructural evolution of MX-80 buffer is presented in the report.Quantification of the microstructure is made by use of digitalized micrographs taken by transmission electron microscopy using suitably impregnated specimens with appropriate thickness. The model is termed MMM, a successor of the earlier GMM. Practically useful microstructural parameters refer to the fraction of a thin section that represents dense and soft parts of the clay matrix. The derived microstructural parameters are directly coupled to the most important bulk physical properties, i.e. the hydraulic conductivity, gas penetrability, swelling pressure and cation/anion diffusion capacities. The study has shown that even at very high densities, softer and more pervious zones exist in the form of interconnected 'external' voids filled with more or less dense clay gels. At bulk densities exceeding 2000 kg/m{sup 3} after water saturation, the gel density is also high but for low bulk densities it may be so much reduced that the gels do not remain stable at high electrolyte content of the pore water. The fact that the density variations are small for high bulk densities means that the separation of matrix components ('fracturing') that is required for letting gas through is on the same order of magnitude as the bulk swelling pressure. For lower bulk densities, displacement or consolidation of the clay gels in 'external' voids is concluded to take place in conjunction with gas penetration. At high densities the limited degree of continuity and constrictions of the channels leading to anion-excluding charge conditions mean that the anion diffusion capacity is very low, while cation diffusion may be extensive because it takes place not only through channels but also through the inter lamellar space and along the surfaces of stacks of lamellae, i.e. by surface diffusion. Two Pre-Quaternary clays that have been investigated and characterized with respect to the

  18. Historical Cavern Floor Rise for All SPR Sites

    Energy Technology Data Exchange (ETDEWEB)

    Moriarty, Dylan Michael [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-09-01

    The Strategic Petroleum Reserve (SPR) contains the largest supply is the largest stockpile of government-owned emergency crude oil in the world. The oil is stored in multiple salt caverns spread over four sites in Louisiana and Texas. Cavern infrastructure near the bottom of the cavern can be damaged from vertical floor movement. This report presents a comprehensive history of floor movements in each cavern. Most of the cavern floor rise rates ranged from 0.5-3.5 ft/yr, however, there were several caverns with much higher rise rates. BH103, BM106, and BH105 had the three highest rise rates. Information from this report will be used to better predict future vertical floor movements and optimally place cavern infrastructure. The reasons for floor rise are not entirely understood and should be investigated.

  19. Influence of flooring type during transport and holding on bacteria recovery from broiler carcass rinses before and after defeathering.

    Science.gov (United States)

    Buhr, R J; Cason, J A; Dickens, J A; Hinton, A; Ingram, K D

    2000-03-01

    Four trials were conducted to determine whether conventional solid or elevated wire mesh flooring, during transport and holding of broilers prior to slaughter, influenced the number of bacteria recovered from feathered and defeathered carcasses. After 4 h off feed, 7-wk-old broilers were placed at commercial density into a modified commercial transport dump-coop on either fiberglass sheeting or 2.54x2.54 cm wire mesh flooring that allowed feces to fall through. Broilers were transported for 1 h and then held for 13 h under a covered shed before processing. Broilers were killed by electrocution, and the vents were plugged to prevent escape of feces. External carcass rinses were obtained twice (from the same carcass) from eight broilers per flooring treatment per trial, before scalding and defeathering and again after defeathering and removal of the head and feet. Greater numbers of total aerobes, coliforms, and Escherichia coli were recovered from feathered carcasses than from defeathered carcasses. Campylobacter count was also less for defeathered than feathered carcasses from the solid flooring treatment but did not significantly decrease following defeathering of carcasses from the wire flooring. The incidence of Campylobacter-positive carcasses was reduced following defeathering for both flooring treatments, but the percentage of Salmonellae-positive carcasses remained constant. Coliform (log10 6.20 vs. 5.63 cfu/mL of rinse) and E. coli (log10 5.93 vs. 5.36) counts in the feathered rinses were significantly higher for the solid flooring compared with wire flooring, respectively. After defeathering, the number of coliforms (log10 3.12) and E. coli (log10 2.91) recovered did not differ between flooring treatments. Aerobic plate count (log10 7.06 and 4.02), Campylobacter count (log10 2.49 and 1.80), and the incidence of Campylobacter-positive (44 and 11%) and Salmonellae-positive (52 and 50%) carcasses for feathered and defeathered rinses, respectively, did not

  20. Association between preterm labour and pelvic floor muscle function.

    Science.gov (United States)

    Aran, Turhan; Pekgöz, Ipek; Bozkaya, Hasan; Osmanagaoglu, Mehmet A

    2018-03-23

    We hypothesised that the pressure on the cervix increases with advancing gestation and it may lead to a cervical shortening and cause preterm labour in women with weak pelvic floor muscles. The aim of this prospective study was to measure vaginal resting pressure and pelvic floor muscle strength in the first trimester of pregnancy and to investigate their effects on labour. A study was conducted on the pregnant women with a low risk for preterm birth. The pelvic floor muscle strength and vaginal resting pressure were assessed in 320 pregnant women at their first trimester with a vaginal pressure measurement device. Fifty-two pregnant women were hospitalised for tocolytic therapy because of spontaneous preterm labour. Thirty-two of them (10.2%) had a preterm delivery despite the tocolytic therapy. Both the vaginal resting pressure (p = .009, 95%CI: 0.8; 5.9) and the pelvic floor muscle strength (p = .01, 95%CI: 3.5; 13.1) were significantly lower in the women with a preterm labour. Impact statement What is already known on this subject? The pelvic floor muscles have an essential role in continence and provide support to the pelvic organs. They also have an impact on labour. The pelvic floor muscles should distend to allow the passage of the foetus during labour. The rotation and flexion of the foetal head is due to the pelvic floor resistance. The effect of a vaginal birth on the pelvic floor's function is readily understood. On the other hand, the effect of the pelvic floor muscle function on labour is still controversial. What do the results of this study add? This prospective study showed that there is a negative association between the pelvic floor muscle strength and preterm labour. This is the first clinical study indicating that weak pelvic floor muscles may cause a preterm labour. What are the implications of these findings for clinical practice and/or further research? Pelvic floor physical therapy may be an alternative preventive strategy to reduce

  1. Biomechanics of the pelvic floor musculature

    NARCIS (Netherlands)

    Janda, S.

    2006-01-01

    The present thesis was motivated by two main goals. The first research goal of the thesis was to understand the complex biomechanical behaviour of the pelvic floor muscles. The second goal was to study the mechanism of the pelvic organ prolapse (genital prolapse). The pelvic floor in humans is a

  2. A new approach to the problem of bulk-mediated surface diffusion.

    Science.gov (United States)

    Berezhkovskii, Alexander M; Dagdug, Leonardo; Bezrukov, Sergey M

    2015-08-28

    This paper is devoted to bulk-mediated surface diffusion of a particle which can diffuse both on a flat surface and in the bulk layer above the surface. It is assumed that the particle is on the surface initially (at t = 0) and at time t, while in between it may escape from the surface and come back any number of times. We propose a new approach to the problem, which reduces its solution to that of a two-state problem of the particle transitions between the surface and the bulk layer, focusing on the cumulative residence times spent by the particle in the two states. These times are random variables, the sum of which is equal to the total observation time t. The advantage of the proposed approach is that it allows for a simple exact analytical solution for the double Laplace transform of the conditional probability density of the cumulative residence time spent on the surface by the particle observed for time t. This solution is used to find the Laplace transform of the particle mean square displacement and to analyze the peculiarities of its time behavior over the entire range of time. We also establish a relation between the double Laplace transform of the conditional probability density and the Fourier-Laplace transform of the particle propagator over the surface. The proposed approach treats the cases of both finite and infinite bulk layer thicknesses (where bulk-mediated surface diffusion is normal and anomalous at asymptotically long times, respectively) on equal footing.

  3. Motor cortical representation of the pelvic floor muscles.

    Science.gov (United States)

    Schrum, A; Wolff, S; van der Horst, C; Kuhtz-Buschbeck, J P

    2011-07-01

    Pelvic floor muscle training involves rhythmical voluntary contractions of the external urethral sphincter and ancillary pelvic floor muscles. The representation of these muscles in the motor cortex has not been located precisely and unambiguously. We used functional magnetic resonance imaging to determine brain activity during slow and fast pelvic floor contractions. Cerebral responses were recorded in 17 healthy male volunteers, 21 to 47 years old, with normal bladder control. Functional magnetic resonance imaging was performed during metronome paced slow (0.25 Hertz) and fast (0.7 Hertz) contractions of the pelvic floor that mimicked the interruption of voiding. To study the somatotopy of the cortical representations, flexion-extension movements of the right toes were performed as a control task. Functional magnetic resonance imaging during pelvic floor contractions detected activity of the supplementary motor area in the medial wall and of the midcingulate cortex, insula, posterior parietal cortex, putamen, thalamus, cerebellar vermis and upper ventral pons. There were no significant differences in activation between slow and fast contractions. Toe movements involved significantly stronger activity of the paracentral lobule (ie the medial primary motor cortex) than did the pelvic floor contractions. Otherwise the areas active during pelvic floor and leg muscle contractions overlapped considerably. The motor cortical representation of pelvic floor muscles is located mostly in the supplementary motor area. It extends further ventrally and anteriorly than the representation of distal leg muscles. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  4. Interferometric density measurements in the divertor and edge plasma regions for the additionally heated JT-60 plasmas

    International Nuclear Information System (INIS)

    Fukuda, T.; Yoshida, H.; Nagashima, A.; Ishida, S.; Kikuchi, M.; Yokomizo, H.

    1989-01-01

    The first divertor plasma density measurement and the interferometric edge plasma density measurement with boundary condition preserving millimeter waveguides were demonstrated to elucidate the mutual correlation among the divertor plasma, scrape-off layer plasma and the bulk plasma properties in the additionally heated JT-60 plasmas. The electron density in the divertor region exhibited a nonlinear dependence on the bulk plasma density for the joule-heated plasmas. When neutral beam heating is applied on the plasmas with the electron density above 2x10 19 /m 3 , however, the bulk plasma density is scraped off from the outer region to lead to density clamping, and the electron density in the divertor region rapidly increases over 1x10 20 /m 3 , from which we can deduce that the particle flow along the magnetic field is dominant, resulting in the apparent degradation of the particle confinement time. As for the case when neutral beam injection is applied to low-density plasmas, the bulk plasma electron density profile becomes flattened to yield a smaller density increase in the divertor region and no density clamping of the bulk plasma was observed. Simulation analysis which correlates the transport of the divertor plasma and the scrape-off layer plasma was also carried out to find the consistency with the experimental results. (orig.)

  5. 9 CFR 91.26 - Concrete flooring.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Concrete flooring. 91.26 Section 91.26... LIVESTOCK FOR EXPORTATION Inspection of Vessels and Accommodations § 91.26 Concrete flooring. (a) Pens aboard an ocean vessel shall have a 3 inch concrete pavement, proportioned and mixed to give 2000 psi...

  6. Restoring the consistency with the contact density theorem of a classical density functional theory of ions at a planar electrical double layer.

    Science.gov (United States)

    Gillespie, Dirk

    2014-11-01

    Classical density functional theory (DFT) of fluids is a fast and efficient theory to compute the structure of the electrical double layer in the primitive model of ions where ions are modeled as charged, hard spheres in a background dielectric. While the hard-core repulsive component of this ion-ion interaction can be accurately computed using well-established DFTs, the electrostatic component is less accurate. Moreover, many electrostatic functionals fail to satisfy a basic theorem, the contact density theorem, that relates the bulk pressure, surface charge, and ion densities at their distances of closest approach for ions in equilibrium at a smooth, hard, planar wall. One popular electrostatic functional that fails to satisfy the contact density theorem is a perturbation approach developed by Kierlik and Rosinberg [Phys. Rev. A 44, 5025 (1991)PLRAAN1050-294710.1103/PhysRevA.44.5025] and Rosenfeld [J. Chem. Phys. 98, 8126 (1993)JCPSA60021-960610.1063/1.464569], where the full free-energy functional is Taylor-expanded around a bulk (homogeneous) reference fluid. Here, it is shown that this functional fails to satisfy the contact density theorem because it also fails to satisfy the known low-density limit. When the functional is corrected to satisfy this limit, a corrected bulk pressure is derived and it is shown that with this pressure both the contact density theorem and the Gibbs adsorption theorem are satisfied.

  7. Surgical reconstruction of pelvic floor descent: anatomic and functional aspects.

    Science.gov (United States)

    Wagenlehner, F M E; Bschleipfer, T; Liedl, B; Gunnemann, A; Petros, P; Weidner, W

    2010-01-01

    The human pelvic floor is a complex structure and pelvic floor dysfunction is seen frequently in females. This review focuses on the surgical reconstruction of the pelvic floor employing recent findings on functional anatomy. A selective literature research was performed by the authors. Pelvic floor activity is regulated by 3 main muscular forces that are responsible for vaginal tension and suspension of the pelvic floor organs, bladder and rectum. A variety of symptoms can derive from pelvic floor dysfunctions, such as urinary urge and stress incontinence, abnormal bladder emptying, fecal incontinence, obstructive bowel disease syndrome and pelvic pain. These symptoms mainly derive, for different reasons, from laxity in the vagina or its supporting ligaments as a result of altered connective tissue. Pelvic floor reconstruction is nowadays driven by the concept that in case of pelvic floor symptoms, restoration of the anatomy will translate into restoration of the physiology and ultimately improve patients' symptoms. The surgical reconstruction of the anatomy is almost exclusively focused on the restoration of the lax pelvic floor ligaments. Exact preoperative identification of the anatomical lesions is necessary to allow for exact anatomical reconstruction with respect to the muscular forces of the pelvic floor. Copyright 2010 S. Karger AG, Basel.

  8. Study of peak broadening effect in floor time histories

    International Nuclear Information System (INIS)

    Soni, R.S.; Kushwaha, H.S.; Mahajan, S.C.; Kakodkar, A.

    1996-01-01

    Seismic design of secondary systems such components and piping is usually carried out by using the floor motions at their support points. These floor motions can be in the form of Floor Response Spectra (FRS) or the Floor Time Histories (FTH). In order to account for the various uncertainties in generating these floor motions, these motions should be peak broadened and smoothened as per the regulatory codes. Presented here in this paper is the methodology to account for such peak broadening effect in the FTH. Results of this study have been compared with the FRS approach and various important conclusions have been arrived at based on the study

  9. An Improved Prediction Model for the Impact Sound Level of Lightweight Floors: Introducing Decoupled Floor-Ceiling and Beam-Plate Moment

    DEFF Research Database (Denmark)

    Mosharrof, Mohammad Sazzad; Brunskog, Jonas; Ljunggren, Fredrik

    2011-01-01

    the impact sound pressure level in a receiving room for a coupled floor structure where floor and ceiling are rigidly connected by beams. A theoretical model for predicting the impact sound level for a decoupled floor structure, which has no rigid mechanical connections between the floor and the ceiling......, is developed. An analytical method has been implemented, where a spatial Fourier transform method as well as the Poisson’s sum formula is applied to model transformed plate displacements. Radiated sound power was calculated from these displacements and normalized sound pressure levels were calculated in one...... and is found to be dependent on frequency, showing significant improvement in predicting impact sound level at high frequency region....

  10. Comparison of changes in the mobility of the pelvic floor muscle on during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction.

    Science.gov (United States)

    Jung, Halim; Jung, Sangwoo; Joo, Sunghee; Song, Changho

    2016-01-01

    [Purpose] The purpose of this study was to compare changes in the mobility of the pelvic floor muscle during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction. [Subjects] Thirty healthy adults participated in this study (15 men and 15 women). [Methods] All participants performed a bridge exercise and abdominal curl-up during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction. Pelvic floor mobility was evaluated as the distance from the bladder base using ultrasound. [Results] According to exercise method, bridge exercise and abdominal curl-ups led to significantly different pelvic floor mobility. The pelvic floor muscle was elevated during the abdominal drawing-in maneuver and descended during maximal expiration. Finally, pelvic floor muscle mobility was greater during abdominal curl-up than during the bridge exercise. [Conclusion] According to these results, the abdominal drawing-in maneuver induced pelvic floor muscle contraction, and pelvic floor muscle contraction was greater during the abdominal curl-up than during the bridge exercise.

  11. Superhard MgB sub 2 bulk material prepared by high-pressure sintering

    CERN Document Server

    Ma, H A; Chen, L X; Zhu, P W; Ren, G Z; Guo, W L; Fu, X Q; Zou Guang Tian; Ren, Z A; Che, G C; Zhao, Z X

    2002-01-01

    Superhard MgB sub 2 bulk material with a golden metallic shine was synthesized by high-pressure sintering for 8 h at 5.5 GPa and different temperatures. Appropriate pressure and temperature conditions for synthesizing polycrystalline MgB sub 2 with high hardness were investigated. The samples were characterized by means of atomic force microscopy and x-ray diffraction. The Vickers hardness, bulk density, and electrical resistivity were measured at room temperature.

  12. FLOOR IDENTIFICATION WITH COMMERCIAL SMARTPHONES IN WIFI-BASED INDOOR LOCALIZATION SYSTEM

    Directory of Open Access Journals (Sweden)

    H. J. Ai

    2016-06-01

    Full Text Available In this paper, we utilize novel sensors built-in commercial smart devices to propose a schema which can identify floors with high accuracy and efficiency. This schema can be divided into two modules: floor identifying and floor change detection. Floor identifying module starts at initial phase of positioning, and responsible for determining which floor the positioning start. We have estimated two methods to identify initial floor based on K-Nearest Neighbors (KNN and BP Neural Network, respectively. In order to improve performance of KNN algorithm, we proposed a novel method based on weighting signal strength, which can identify floors robust and quickly. Floor change detection module turns on after entering into continues positioning procedure. In this module, sensors (such as accelerometer and barometer of smart devices are used to determine whether the user is going up and down stairs or taking an elevator. This method has fused different kinds of sensor data and can adapt various motion pattern of users. We conduct our experiment with mobile client on Android Phone (Nexus 5 at a four-floors building with an open area between the second and third floor. The results demonstrate that our scheme can achieve an accuracy of 99% to identify floor and 97% to detecting floor changes as a whole.

  13. Effects of bulk charged impurities on the bulk and surface transport in three-dimensional topological insulators

    Energy Technology Data Exchange (ETDEWEB)

    Skinner, B.; Chen, T.; Shklovskii, B. I., E-mail: shklovsk@physics.spa.umn.edu [University of Minnesota, Fine Theoretical Physics Institute (United States)

    2013-09-15

    In the three-dimensional topological insulator (TI), the physics of doped semiconductors exists literally side-by-side with the physics of ultrarelativistic Dirac fermions. This unusual pairing creates a novel playground for studying the interplay between disorder and electronic transport. In this mini-review, we focus on the disorder caused by the three-dimensionally distributed charged impurities that are ubiquitous in TIs, and we outline the effects it has on both the bulk and surface transport in TIs. We present self-consistent theories for Coulomb screening both in the bulk and at the surface, discuss the magnitude of the disorder potential in each case, and present results for the conductivity. In the bulk, where the band gap leads to thermally activated transport, we show how disorder leads to a smaller-than-expected activation energy that gives way to variable-range hopping at low temperatures. We confirm this enhanced conductivity with numerical simulations that also allow us to explore different degrees of impurity compensation. For the surface, where the TI has gapless Dirac modes, we present a theory of disorder and screening of deep impurities, and we calculate the corresponding zero-temperature conductivity. We also comment on the growth of the disorder potential in passing from the surface of the TI into the bulk. Finally, we discuss how the presence of a gap at the Dirac point, introduced by some source of time-reversal symmetry breaking, affects the disorder potential at the surface and the mid-gap density of states.

  14. Effects of bulk charged impurities on the bulk and surface transport in three-dimensional topological insulators

    International Nuclear Information System (INIS)

    Skinner, B.; Chen, T.; Shklovskii, B. I.

    2013-01-01

    In the three-dimensional topological insulator (TI), the physics of doped semiconductors exists literally side-by-side with the physics of ultrarelativistic Dirac fermions. This unusual pairing creates a novel playground for studying the interplay between disorder and electronic transport. In this mini-review, we focus on the disorder caused by the three-dimensionally distributed charged impurities that are ubiquitous in TIs, and we outline the effects it has on both the bulk and surface transport in TIs. We present self-consistent theories for Coulomb screening both in the bulk and at the surface, discuss the magnitude of the disorder potential in each case, and present results for the conductivity. In the bulk, where the band gap leads to thermally activated transport, we show how disorder leads to a smaller-than-expected activation energy that gives way to variable-range hopping at low temperatures. We confirm this enhanced conductivity with numerical simulations that also allow us to explore different degrees of impurity compensation. For the surface, where the TI has gapless Dirac modes, we present a theory of disorder and screening of deep impurities, and we calculate the corresponding zero-temperature conductivity. We also comment on the growth of the disorder potential in passing from the surface of the TI into the bulk. Finally, we discuss how the presence of a gap at the Dirac point, introduced by some source of time-reversal symmetry breaking, affects the disorder potential at the surface and the mid-gap density of states

  15. The influence of flooring on environmental stressors: a study of three flooring materials in a hospital.

    Science.gov (United States)

    Harris, Debra D

    2015-01-01

    Three flooring materials, terrazzo, rubber, and carpet tile, in patient unit corridors were compared for absorption of sound, comfort, light reflectance, employee perceptions and preferences, and patient satisfaction. Environmental stressors, such as noise and ergonomic factors, effect healthcare workers and patients, contributing to increased fatigue, anxiety and stress, decreased productivity, and patient safety and satisfaction. A longitudinal comparative cohort study comparing three types of flooring assessed sound levels, healthcare worker responses, and patient Hospital Consumer Assessment of Healthcare Providers and Systems (HCAHPS) ratings over 42 weeks. A linear mixed model analysis was conducted to determine significant differences between the means for participant responses and objective sound meter data during all three phases of the study. A significant difference was found for sound levels between flooring type for equivalent continuous sound levels. Carpet tile performed better for sound attenuation by absorption, reducing sound levels 3.14 dBA. Preferences for flooring materials changed over the course of the study. The HCAHPS ratings aligned with the sound meter data showing that patients perceived the noise levels to be lower with carpet tiles, improving patient satisfaction ratings. Perceptions for healthcare staff and patients were aligned with the sound meter data. Carpet tile provides sound absorption that affects sound levels and influences occupant's perceptions of environmental factors that contribute to the quality of the indoor environment. Flooring that provides comfort underfoot, easy cleanability, and sound absorption influence healthcare worker job satisfaction and patient satisfaction with their patient experience. © The Author(s) 2015.

  16. Recognition and Management of Nonrelaxing Pelvic Floor Dysfunction

    Science.gov (United States)

    Faubion, Stephanie S.; Shuster, Lynne T.; Bharucha, Adil E.

    2012-01-01

    Nonrelaxing pelvic floor dysfunction is not widely recognized. Unlike in pelvic floor disorders caused by relaxed muscles (eg, pelvic organ prolapse or urinary incontinence, both of which often are identified readily), women affected by nonrelaxing pelvic floor dysfunction may present with a broad range of nonspecific symptoms. These may include pain and problems with defecation, urination, and sexual function, which require relaxation and coordination of pelvic floor muscles and urinary and anal sphincters. These symptoms may adversely affect quality of life. Focus on the global symptom complex, rather than the individual symptoms, may help the clinician identify the condition. The primary care provider is in a position to intervene early, efficiently, and effectively by (1) recognizing the range of symptoms that might suggest nonrelaxing pelvic floor dysfunction, (2) educating patients, (3) performing selective tests when needed to confirm the diagnosis, and (4) providing early referral for physical therapy. PMID:22305030

  17. Glazed Tiles as Floor Finish in Nigeria

    Directory of Open Access Journals (Sweden)

    Toyin Emmanuel AKINDE

    2013-09-01

    Full Text Available Tile is no doubt rich in antiquity; its primordial  show, came as mosaic with primary prospect in sacred floor finish before its oblivion, courtesy of, later consciousness towards wall finish in banquets, kitchens, toilets, restaurants and even bars. Today, its renaissance as floor finish is apparent in private and public architectural structures with prevalence in residential, recreational, commercial, governmental and other spaces. In Nigeria, the use of glazed tiles as floor finish became apparent, supposedly in mid-twentieth century; and has since, witnessed ever increasing demands from all sundry; a development that is nascent and has necessitated its mass  production locally with pockets of firms in the country. The latter however, is a resultant response to taste cum glazed tiles affordability, whose divergent sophistication in design, colour, size and shape is believed preferred to terrazzo, carpet and floor flex tile. Accessible as glazed tile and production is, in recent times; its dearth of a holistic literature in Nigeria is obvious. In the light of the latter, this paper examine glazed tiles as floor finish in Nigeria, its advent, usage, production, challenge, benefit and prospect with the hope of opening further frontier in discipline specifics.

  18. WOODEN FLOORING – BETWEEN PRESENT AND FUTURE

    Directory of Open Access Journals (Sweden)

    Ivan CISMARU

    2015-06-01

    Full Text Available The paper aims at presenting a systematization of the wood floors, both in terms of the areas of application, and in terms of the fastening solutions and structures in constructions. In this respect, an extensive bibliographic research was achieved, on the researchers’ preoccupations. Starting from the current situation and forecasting the future, from the point of view of the chances held by wooden flooring, in competition with other types of materials, we dare say the wooden flooring or the wood in combination with other materials are not likely to be eliminated from the “civil-engineering market”. The wood floors are likely to develop as an application, especially in the area of the “special floors”, specific to the indoor sports or social halls; and even for some industrial sectors, with strict operating conditions (elasticity, thermal insulation, soundproofing that cannot be provided by other types of materials or structures. Starting from this last observation, the paper also aims at submitting current opinions with respect to this type of floors, both in the light of the current databases and in the light of the future researches, to this end

  19. Photocarrier dynamics in monolayer phosphorene and bulk black phosphorus.

    Science.gov (United States)

    Zereshki, Peymon; Wei, Yaqing; Ceballos, Frank; Bellus, Matthew Z; Lane, Samuel D; Pan, Shudi; Long, Run; Zhao, Hui

    2018-06-13

    We report a combined theoretical and experimental study on photocarrier dynamics in monolayer phosphorene and bulk black phosphorus. Samples of monolayer phosphorene and bulk black phosphorus were fabricated by mechanical exfoliation, identified according to their reflective contrasts, and protected by covering them with hexagonal boron nitride layers. Photocarrier dynamics in these samples was studied by an ultrafast pump-probe technique. The photocarrier lifetime of monolayer phosphorene was found to be about 700 ps, which is about 9 times longer than that of bulk black phosphorus. This trend was reproduced in our calculations based on ab initio nonadiabatic molecular dynamics combined with time-domain density functional theory in the Kohn-Sham representation, and can be attributed to the smaller bandgap and stronger nonadiabatic coupling in bulk. The transient absorption response was also found to be dependent on the sample orientation with respect to the pump polarization, which is consistent with the previously reported anisotropic absorption of phosphorene. In addition, an oscillating component of the differential reflection signal at early probe delays was observed in the bulk sample and was attributed to the layer-breathing phonon mode with an energy of about 1 meV and a decay time of about 1.35 ps. These results provide valuable information for application of monolayer phosphorene in optoelectronics.

  20. What Is Low Profile Access Flooring and Why More Businesses Need It

    OpenAIRE

    NetfloorUSA

    2017-01-01

    Low profile access flooring is being commonly used in a variety of businesses today. To understand why more businesses, need this type of flooring, it is essential that we take the time to first understand what is low profile flooring actually is. What Is Low Profile Access Flooring A low profile access floor is a floor that is designed to sit above the original concrete slab flooring installed in any home, business, or public building. The higher floor height creates a space between ...

  1. Polygons on Crater Floor

    Science.gov (United States)

    2003-01-01

    MGS MOC Release No. MOC2-357, 11 May 2003This Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) picture shows a pattern of polygons on the floor of a northern plains impact crater. These landforms are common on crater floors at high latitudes on Mars. Similar polygons occur in the arctic and antarctic regions of Earth, where they indicate the presence and freeze-thaw cycling of ground ice. Whether the polygons on Mars also indicate water ice in the ground is uncertain. The image is located in a crater at 64.8oN, 292.7oW. Sunlight illuminates the scene from the lower left.

  2. 17 CFR 240.11a-1 - Regulation of floor trading.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Regulation of floor trading... Securities Exchange Act of 1934 Adoption of Floor Trading Regulation (rule 11a-1) § 240.11a-1 Regulation of floor trading. (a) No member of a national securities exchange, while on the floor of such exchange...

  3. Physical distribution of oak strip flooring 1969

    Science.gov (United States)

    William C. Miller; William C. Miller

    1971-01-01

    As an aid to the marketing of oak strip flooring, a study was made of the distribution process for this product, from manufacture to consumer-where the flooring came from, where it went, how much was shipped, and who handled it.

  4. Pelvic floor muscle training as a persistent nursing intervention: Effect on delivery outcome and pelvic floor myodynamia

    Directory of Open Access Journals (Sweden)

    Xin Wang

    2014-03-01

    Conclusion: Persistent nursing intervention for pregnant/postpartum women helped to shorten the second stage of labour and contributed to the recovery of postpartum pelvic floor myodynamia. The influence of this intervention on the delivery mode, and rates of episiotomy and perineal laceration remains unknown. Medical staff should strengthen health education programmes that involve pelvic floor functional rehabilitation.

  5. Assessment of the effect of pelvic floor exercises on pelvic floor muscle strength using ultrasonography in patients with urinary incontinence: a prospective randomized controlled trial

    OpenAIRE

    Tosun, Ozge Celiker; Solmaz, Ulas; Ekin, Atalay; Tosun, Gokhan; Gezer, Cenk; Ergenoglu, Ahmet Mete; Yeniel, Ahmet Ozgur; Mat, Emre; Malkoc, Mehtap; Askar, Niyazi

    2016-01-01

    [Purpose] The aim of this study was to evaluate whether the effect of pelvic floor exercises on pelvic floor muscle strength could be detected via ultrasonography in patients with urinary incontinence. [Subjects and Methods] Of 282 incontinent patients, 116 participated in the study and were randomly divided into a pelvic floor muscle training (n=65) group or control group (n=51). The pelvic floor muscle training group was given pelvic floor exercise training for 12 weeks. Both groups were ev...

  6. Generation of floor spectra compatible time histories for equipment seismic qualification in nuclear power plants

    International Nuclear Information System (INIS)

    Shyu, Y.-S.; Luh, Gary G.; Blum, Arie

    2004-01-01

    This paper proposes a procedure for generating floor response spectra compatible time histories used for equipment seismic qualification in nuclear power plants. From the 84th percentile power spectrum density function of an earthquake ensemble of four randomly generated time history motions, a statistically equivalent time history can be obtained by converting the power spectrum density function from the frequency domain into the time domain. With minor modification, if needed, the converted time history will satisfy both the spectral and the power spectrum density enveloping criteria, as required by the USNRC per Revision 2 of the Standard Review Plan, Section 3.7.1. Step-by-step generating procedures and two numerical examples are presented to illustrate the applications of the methodology. (author)

  7. Air gun near the sea floor as shear-wave source?

    NARCIS (Netherlands)

    Drijkoningen, G.G.; Dieulangard, D.; Holicki, M.E.

    2015-01-01

    The feasibility of using an air gun near the sea floor as shear-wave source has been investigated. With an air gun near the sea floor, an evanescent P-wave in the water becomes a propagating S-wave in the sea floor, such that it seems that a pure shear-wave source has been used at the sea floor.

  8. Dermoid cyst in the mouth floor

    International Nuclear Information System (INIS)

    Portelles Masso, Ayelen Maria; Torres Inniguez, Ailin Tamara.

    2010-01-01

    The Dermoid cyst account for the 0.01 % of all cysts of buccal cavity. Its more frequent location is in the mouth floor. This is the case of a female patient aged 19 who approximately 7 years noted an increase of volume under tongue growing gradually and noting outside face and the discomfort at to speak and to chew. Complementary studies were conducted and under general anesthesia a surgical exeresis was carried out by intrabuccal approach achieving excellent esthetic and functional results. Histopathologic diagnosis matched with a dermoid cyst of mouth floor. Patient has not lesion recurrence after three years after operation. We conclude that the Dermoid cyst of mouth floor appear as benign tumor of middle line. The intrabuccal exeresis demonstrates esthetic and functional benefits. (author)

  9. Bulk and interfacial structures of reline deep eutectic solvent: A molecular dynamics study.

    Science.gov (United States)

    Kaur, Supreet; Sharma, Shobha; Kashyap, Hemant K

    2017-11-21

    We apply all-atom molecular dynamics simulations to describe the bulk morphology and interfacial structure of reline, a deep eutectic solvent comprising choline chloride and urea in 1:2 molar ratio, near neutral and charged graphene electrodes. For the bulk phase structural investigation, we analyze the simulated real-space radial distribution functions, X-ray/neutron scattering structure functions, and their partial components. Our study shows that both hydrogen-bonding and long-range correlations between different constituents of reline play a crucial role to lay out the bulk structure of reline. Further, we examine the variation of number density profiles, orientational order parameters, and electrostatic potentials near the neutral and charged graphene electrodes with varying electrode charge density. The present study reveals the presence of profound structural layering of not only the ionic components of reline but also urea near the electrodes. In addition, depending on the electrode charge density, the choline ions and urea molecules render different orientations near the electrodes. The simulated number density and electrostatic potential profiles for reline clearly show the presence of multilayer structures up to a distance of 1.2 nm from the respective electrodes. The observation of positive values of the surface potential at zero charge indicates the presence of significant nonelectrostatic attraction between the choline cation and graphene electrode. The computed differential capacitance (C d ) for reline exhibits an asymmetric bell-shaped curve, signifying different variation of C d with positive and negative surface potentials.

  10. Gap-related trapped magnetic flux dependence between single and combined bulk superconductors

    International Nuclear Information System (INIS)

    Deng, Z.; Miki, M.; Felder, B.; Tsuzuki, K.; Shinohara, N.; Uetake, T.; Izumi, M.

    2011-01-01

    Highlights: → Rectangular YBCO bulks to realize a compact combination. → The gap effect was added to consider in the trapped flux density mapping. → The trapped-flux dependence between single and combined bulks is gap related. → It is possible to estimate the total magnetic flux of bulk combinations. - Abstract: Aiming at examining the trapped-flux dependence between single and combined bulk superconductors for field-pole applications, three rectangular Y 1.65 Ba 2 Cu 3 O 7-x (YBCO) bulks with a possibly compact combination were employed to investigate the trapped-flux characteristics of single and combined bulks with a field-cooling magnetization (FCM) method. A gap-related dependence was found between them. At lower gaps of 1 mm and 5 mm, the peak trapped fields and total magnetic flux of combined bulks are both smaller than the additive values of each single bulk, which can be ascribed to the demagnetization influences of the field around the bulk generated by the adjacent ones. While, at larger gaps like 10 mm, the situation becomes reversed. The combined bulks can attain bigger peak trapped fields as well as total magnetic flux, which indicates that the magnetic field by the bulk combination can reach higher gaps, thanks to the bigger magnetic energy compared with the single bulk. The presented results show that, on one hand, it is possible to estimate the total trapped magnetic flux of combined bulks by an approximate additive method of each single bulk while considering a demagnetization factor; on the other hand, it also means that the performance of combined bulks will be superior to the addition of each single bulk at larger gaps, thus preferable for large-scaled magnet applications.

  11. Gap-related trapped magnetic flux dependence between single and combined bulk superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Z., E-mail: zgdeng@gmail.co [Laboratory of Applied Physics, Department of Marine Electronics and Mechanical Engineering, Tokyo University of Marine Science and Technology, Tokyo 135-8533 (Japan); Miki, M.; Felder, B.; Tsuzuki, K.; Shinohara, N.; Uetake, T.; Izumi, M. [Laboratory of Applied Physics, Department of Marine Electronics and Mechanical Engineering, Tokyo University of Marine Science and Technology, Tokyo 135-8533 (Japan)

    2011-05-15

    Highlights: {yields} Rectangular YBCO bulks to realize a compact combination. {yields} The gap effect was added to consider in the trapped flux density mapping. {yields} The trapped-flux dependence between single and combined bulks is gap related. {yields} It is possible to estimate the total magnetic flux of bulk combinations. - Abstract: Aiming at examining the trapped-flux dependence between single and combined bulk superconductors for field-pole applications, three rectangular Y{sub 1.65}Ba{sub 2}Cu{sub 3}O{sub 7-x} (YBCO) bulks with a possibly compact combination were employed to investigate the trapped-flux characteristics of single and combined bulks with a field-cooling magnetization (FCM) method. A gap-related dependence was found between them. At lower gaps of 1 mm and 5 mm, the peak trapped fields and total magnetic flux of combined bulks are both smaller than the additive values of each single bulk, which can be ascribed to the demagnetization influences of the field around the bulk generated by the adjacent ones. While, at larger gaps like 10 mm, the situation becomes reversed. The combined bulks can attain bigger peak trapped fields as well as total magnetic flux, which indicates that the magnetic field by the bulk combination can reach higher gaps, thanks to the bigger magnetic energy compared with the single bulk. The presented results show that, on one hand, it is possible to estimate the total trapped magnetic flux of combined bulks by an approximate additive method of each single bulk while considering a demagnetization factor; on the other hand, it also means that the performance of combined bulks will be superior to the addition of each single bulk at larger gaps, thus preferable for large-scaled magnet applications.

  12. Improving the cleaning procedure to make kitchen floors less slippery.

    Science.gov (United States)

    Quirion, F; Poirier, P; Lehane, P

    2008-12-01

    This investigation shows that, in most cases, the floor cleaning procedure of typical restaurants could be improved, resulting in a better cleaning efficiency and a better floor friction. This simple approach could help reduce slips and falls in the workplace. Food safety officers visited ten European style restaurants in the London Borough of Bromley (UK) to identify their floor cleaning procedure in terms of the cleaning method, the concentration and type of floor cleaner and the temperature of the wash water. For all 10 restaurants visited, the cleaning method was damp mopping. Degreasers were used in three sites while neutral floor cleaners were used in seven sites. Typically, the degreasers were over diluted and the neutrals were overdosed. The wash water temperature ranged from 10 to 72 degrees C. The on-site cleaning procedures were repeated in the laboratory for the removal of olive oil from new and sealed quarry tiles, fouled and worn quarry tiles and new porcelain tiles. It is found that in 24 out of 30 cases, cleaning efficiency can be improved by simple changes in the floor cleaning procedure and that these changes result in a significant improvement of the floor friction. The nature of the improved floor cleaning procedure depends on the flooring type. New and properly sealed flooring tiles can be cleaned using damp mopping with a degreaser diluted as recommended by the manufacturer in warm or hot water (24 to 50 degrees C). But as the tiles become worn and fouled, a more aggressive floor cleaning is required such as two-step mopping with a degreaser diluted as recommended by the manufacturer in warm water (24 degrees C).

  13. Nondestructive structural evaluation of wood floor systems with a vibration technique.

    Science.gov (United States)

    Xiping Wang; Robert J. Ross; Lawrence Andrew Soltis

    2002-01-01

    The objective of this study was to determine if transverse vibration methods could be used to effectively assess the structural integrity of wood floors as component systems. A total of 10 wood floor systems, including 3 laboratory-built floor sections and 7 in-place floors in historic buildings, were tested. A forced vibration method was applied to the floor systems...

  14. Improvement of PVC floor tiles by gamma radiation

    International Nuclear Information System (INIS)

    Plessis, T.A. du; Badenhorst, F.

    1988-01-01

    Gamma radiation presents a unique method of transforming highly plasticized PVC floor tiles, manufactured at high speed through injection moulding, into a high quality floor covering at a cost at least 30% less than similarly rated rubber tiles. A specially formulated PVC compound was developed in collaboration with a leading manufacturer of floor tiles. These tiles are gamma crosslinked in its shipping cartons to form a dimensionally stable product which is highly fire resistant and inert to most chemicals and solvents. These crosslinked tiles are more flexible than the highly filled conventional PVC floor tiles, scratch resistant and have a longer lifespan and increased colour fastness. These tiles are also less expensive to install than conventional rubber tiles. (author)

  15. Instanton-based techniques for analysis and reduction of error floors of LDPC codes

    International Nuclear Information System (INIS)

    Chertkov, Michael; Chilappagari, Shashi K.; Stepanov, Mikhail G.; Vasic, Bane

    2008-01-01

    We describe a family of instanton-based optimization methods developed recently for the analysis of the error floors of low-density parity-check (LDPC) codes. Instantons are the most probable configurations of the channel noise which result in decoding failures. We show that the general idea and the respective optimization technique are applicable broadly to a variety of channels, discrete or continuous, and variety of sub-optimal decoders. Specifically, we consider: iterative belief propagation (BP) decoders, Gallager type decoders, and linear programming (LP) decoders performing over the additive white Gaussian noise channel (AWGNC) and the binary symmetric channel (BSC). The instanton analysis suggests that the underlying topological structures of the most probable instanton of the same code but different channels and decoders are related to each other. Armed with this understanding of the graphical structure of the instanton and its relation to the decoding failures, we suggest a method to construct codes whose Tanner graphs are free of these structures, and thus have less significant error floors.

  16. Instanton-based techniques for analysis and reduction of error floor of LDPC codes

    Energy Technology Data Exchange (ETDEWEB)

    Chertkov, Michael [Los Alamos National Laboratory; Chilappagari, Shashi K [Los Alamos National Laboratory; Stepanov, Mikhail G [Los Alamos National Laboratory; Vasic, Bane [SENIOR MEMBER, IEEE

    2008-01-01

    We describe a family of instanton-based optimization methods developed recently for the analysis of the error floors of low-density parity-check (LDPC) codes. Instantons are the most probable configurations of the channel noise which result in decoding failures. We show that the general idea and the respective optimization technique are applicable broadly to a variety of channels, discrete or continuous, and variety of sub-optimal decoders. Specifically, we consider: iterative belief propagation (BP) decoders, Gallager type decoders, and linear programming (LP) decoders performing over the additive white Gaussian noise channel (AWGNC) and the binary symmetric channel (BSC). The instanton analysis suggests that the underlying topological structures of the most probable instanton of the same code but different channels and decoders are related to each other. Armed with this understanding of the graphical structure of the instanton and its relation to the decoding failures, we suggest a method to construct codes whose Tanner graphs are free of these structures, and thus have less significant error floors.

  17. The pelvic floor muscles: muscle thickness in healthy and urinary-incontinent women measured by perineal ultrasonography with reference to the effect of pelvic floor training. Estrogen receptor studies

    DEFF Research Database (Denmark)

    Bernstein, Inge Thomsen

    1997-01-01

    demonstrated that the striated periurethral muscles and the pelvic floor muscles are of paramount importance for the closure function. This emphasizes the importance of well-functioning pelvic floor muscles to obtain continence, and probably explains the rationale for the effect of pelvic floor training...... in treating urinary incontinence. This study presents a review of the literature on female urinary incontinence, continence mechanisms, pelvic floor muscles, and pelvic floor training. Furthermore, a review of the literature on estrogen receptors in the pelvic floor muscles is given. Perineal ultrasonography...... the effect of pelvic floor training. Additionally, a study of the Pelvic floor muscles was performed to assess the presence of estrogen receptors. Muscle thickness seems to decrease with age. In women over age 60 years, a significantly thinner pelvic floor muscle was found compared to younger women...

  18. Microfabricated Bulk Piezoelectric Transformers

    Science.gov (United States)

    Barham, Oliver M.

    Piezoelectric voltage transformers (PTs) can be used to transform an input voltage into a different, required output voltage needed in electronic and electro- mechanical systems, among other varied uses. On the macro scale, they have been commercialized in electronics powering consumer laptop liquid crystal displays, and compete with an older, more prevalent technology, inductive electromagnetic volt- age transformers (EMTs). The present work investigates PTs on smaller size scales that are currently in the academic research sphere, with an eye towards applications including micro-robotics and other small-scale electronic and electromechanical sys- tems. PTs and EMTs are compared on the basis of power and energy density, with PTs trending towards higher values of power and energy density, comparatively, indicating their suitability for small-scale systems. Among PT topologies, bulk disc-type PTs, operating in their fundamental radial extension mode, and free-free beam PTs, operating in their fundamental length extensional mode, are good can- didates for microfabrication and are considered here. Analytical modeling based on the Extended Hamilton Method is used to predict device performance and integrate mechanical tethering as a boundary condition. This model differs from previous PT models in that the electric enthalpy is used to derive constituent equations of motion with Hamilton's Method, and therefore this approach is also more generally applica- ble to other piezoelectric systems outside of the present work. Prototype devices are microfabricated using a two mask process consisting of traditional photolithography combined with micropowder blasting, and are tested with various output electri- cal loads. 4mm diameter tethered disc PTs on the order of .002cm. 3 , two orders smaller than the bulk PT literature, had the followingperformance: a prototype with electrode area ratio (input area / output area) = 1 had peak gain of 2.3 (+/- 0.1), efficiency of 33 (+/- 0

  19. Piezoelectric energy harvester under parquet floor

    Science.gov (United States)

    Bischur, E.; Schwesinger, N.

    2011-03-01

    The design, fabrication and testing of piezoelectric energy harvesting modules for floors is described. These modules are used beneath a parquet floor to harvest the energy of people walking over it. The harvesting modules consist of monoaxial stretched PVDF-foils. Multilayer modules are built up as roller-type capacitors. The fabrication process of the harvesting modules is simple and very suitable for mass production. Due to the use of organic polymers, the modules are characterized by a great flexibility and the possibility to create them in almost any geometrical size. The energy yield was determined depending on the dynamic loading force, the thickness of piezoelectric active material, the size of the piezoelectric modules, their alignment in the walking direction and their position on the floor. An increase of the energy yield at higher loading forces and higher thicknesses of the modules was observed. It was possible to generate up to 2.1mWs of electric energy with dynamic loads of 70kg using a specific module design. Furthermore a test floor was assembled to determine the influence of the size, alignment and position of the modules on the energy yield.

  20. Preparation and magnetic properties of anisotropic bulk MnBi/NdFeB hybrid magnets

    International Nuclear Information System (INIS)

    Ma, Y.L.; Liu, X.B.; Nguyen, V.V.; Poudyal, N.; Yue, M.; Liu, J.P.

    2016-01-01

    Anisotropic hybrid bulk magnets of MnBi/NdFeB with different composition ratio have been prepared with starting MnBi and Nd 2 Fe 14 B powders as well as epoxy resin as a binder in case it is needed to form bulk samples. It has been found that the ratio between the two phases in content has a remarkable influence on the magnetic properties, the thermal stability and the density of the bulk magnets. With increasing MnBi content the binder addition can be reduced. When the MnBi content is larger than 30 wt%, no binder is needed. On the other hand, the coercivity and saturation magnetization were increased significantly with increasing NdFeB content. When the NdFeB content was increased from 0% to 50%, the maximum energy product was enhanced from 4.7 to 10.0 MGOe, respectively. The energy product then decreased gradually with the NdFeB content due to the reduced density of the hybrid magnet. The thermal stability measurements showed that the temperature coefficient of coercivity grew with the MnBi content and became positive with MnBi=80 wt%. - Highlights: • Anisotropic bulk hybrid MnBi/NdFeB magnets were prepared. • MnBi content affected the density and coercivity temperature coefficient positively. • An energy product (BH) max of 10 MGOe was obtained at NdFeB content of 50 wt%.

  1. Preparation and magnetic properties of anisotropic bulk MnBi/NdFeB hybrid magnets

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Y.L. [Department of Physics, University of Texas at Arlington, Arlington, TX 76019 (United States); College of Metallurgical and Materials Engineering, Chongqing University of Science and Technology, Chongqing 401331 (China); Liu, X.B.; Nguyen, V.V.; Poudyal, N. [Department of Physics, University of Texas at Arlington, Arlington, TX 76019 (United States); Yue, M. [College of Materials Science and Engineering, Beijing University of Technology, Beijing 100124 (China); Liu, J.P., E-mail: pliu@uta.edu [Department of Physics, University of Texas at Arlington, Arlington, TX 76019 (United States)

    2016-08-01

    Anisotropic hybrid bulk magnets of MnBi/NdFeB with different composition ratio have been prepared with starting MnBi and Nd{sub 2}Fe{sub 14}B powders as well as epoxy resin as a binder in case it is needed to form bulk samples. It has been found that the ratio between the two phases in content has a remarkable influence on the magnetic properties, the thermal stability and the density of the bulk magnets. With increasing MnBi content the binder addition can be reduced. When the MnBi content is larger than 30 wt%, no binder is needed. On the other hand, the coercivity and saturation magnetization were increased significantly with increasing NdFeB content. When the NdFeB content was increased from 0% to 50%, the maximum energy product was enhanced from 4.7 to 10.0 MGOe, respectively. The energy product then decreased gradually with the NdFeB content due to the reduced density of the hybrid magnet. The thermal stability measurements showed that the temperature coefficient of coercivity grew with the MnBi content and became positive with MnBi=80 wt%. - Highlights: • Anisotropic bulk hybrid MnBi/NdFeB magnets were prepared. • MnBi content affected the density and coercivity temperature coefficient positively. • An energy product (BH){sub max} of 10 MGOe was obtained at NdFeB content of 50 wt%.

  2. 75 FR 70061 - Dealer Floor Plan Pilot Program Meeting

    Science.gov (United States)

    2010-11-16

    ... SMALL BUSINESS ADMINISTRATION Dealer Floor Plan Pilot Program Meeting AGENCY: U.S. Small Business... location, date, time, and agenda for a meeting regarding the Dealer Floor Plan Pilot Program established in the Small Business Jobs Act of 2010. The meeting will be open to the public. DATES: The Dealer Floor...

  3. Bulk synthesis of nanocrystalline urania powders by citrate gel-combustion method

    International Nuclear Information System (INIS)

    Sanjay Kumar, D.; Ananthasivan, K.; Venkata Krishnan, R.; Amirthapandian, S.; Dasgupta, Arup

    2016-01-01

    Bulk quantities (60 g) of nanocrystalline (nc) free flowing urania powders with crystallite size ranging from 38 to 252 nm have been synthesized for the first time by the citrate gel combustion method. A systematic study of the influence of the fuel (citric acid) to oxidant (nitrate) ratio (R) on the characteristics of the urania powders has been carried out for the first time. Mixture with an “R” value of 0.25 exhibited a vigorous auto-ignition reaction. This reaction was investigated with Differential Scanning Calorimetry (DSC) and in-situ thermogravimetry coupled with differential thermal analysis and mass spectrometry (TG-DTA-MS). The bulk density, specific surface area, X-ray crystallite size, residual carbon and size distribution of particles of this powder were unique. Microscopic and microstructural investigation of selected samples revealed the presence of nanocrystals with irregular exfoliated morphology; their Electron Energy Loss Spectra testified the covalency of the U–O bond. - Highlights: • Bulk quantities of nanocrystalline urania were prepared for the first time using citrate gel combustion method. • Volume combustion was observed in mixtures with fuel to nitrate ratio (R) 0.25. • The value of R was found to significantly influence the characteristics of the final product. • Typical exfoliated microstructure and nanopores were observed. • Established correlation between particle size distribution and bulk density, X-ray crystallite size and lattice strain. • Relationship between fuel to nitrate (R) mole ratio and physical characteristics of powders were also established.

  4. Ploughing the deep sea floor.

    Science.gov (United States)

    Puig, Pere; Canals, Miquel; Company, Joan B; Martín, Jacobo; Amblas, David; Lastras, Galderic; Palanques, Albert

    2012-09-13

    Bottom trawling is a non-selective commercial fishing technique whereby heavy nets and gear are pulled along the sea floor. The direct impact of this technique on fish populations and benthic communities has received much attention, but trawling can also modify the physical properties of seafloor sediments, water–sediment chemical exchanges and sediment fluxes. Most of the studies addressing the physical disturbances of trawl gear on the seabed have been undertaken in coastal and shelf environments, however, where the capacity of trawling to modify the seafloor morphology coexists with high-energy natural processes driving sediment erosion, transport and deposition. Here we show that on upper continental slopes, the reworking of the deep sea floor by trawling gradually modifies the shape of the submarine landscape over large spatial scales. We found that trawling-induced sediment displacement and removal from fishing grounds causes the morphology of the deep sea floor to become smoother over time, reducing its original complexity as shown by high-resolution seafloor relief maps. Our results suggest that in recent decades, following the industrialization of fishing fleets, bottom trawling has become an important driver of deep seascape evolution. Given the global dimension of this type of fishery, we anticipate that the morphology of the upper continental slope in many parts of the world’s oceans could be altered by intensive bottom trawling, producing comparable effects on the deep sea floor to those generated by agricultural ploughing on land.

  5. Industrial tests of rock consolidation for fighting floor swelling

    Energy Technology Data Exchange (ETDEWEB)

    Pirskii, A A; Stovpnik, S N [KPI (USSR)

    1990-04-01

    Reports on investigations into the mechanism of floor swelling in main roadways and into rock mass stabilization by consolidating fluid injection combined with blasting. The principal cause of deterioration in the stability of workings is considered to be the state of stress in the rock mass, rock destruction in side walls where rock blocks are being pressed into the floor while the floor rock is squeezed out into the working space. A case study of fluid injection combined with blasting applied in several mines in the Donbass is presented where holes were drilled 1.5-3 m deep and explosive charges of 0.07-0.1 kg/hole and injection of hardening solutions (0.56-0.83 m{sup 3}/m of workings) were applied. As a result floor swelling rates were reduced by up to about 5 times (e.g. from 2.5 mm/d to 0.5 mm/d.). The period of maintenence free upkeep of workings was extended to 6-8 years. The economic effect in maintenance of 1 m of workings was 11.7 rubles for floor consolidation without sidewall bolting and 51.4 rubles for floor consolidation combined with sidewall bolting. Recommendations that concern the technology of floor consolidation by fluid injection and blasting are made. 4 refs.

  6. Movimento e inativação do metribuzin em materiais de dois solos, sob diferentes densidades aparentes Movement and inactivation of metribuzin in two soil materials with different bulk densities

    Directory of Open Access Journals (Sweden)

    L.E.F. Fontes

    1980-06-01

    Full Text Available Numa série de ensaios em laboratório e casa-de-vegetação, estudou-se a mobilidade e a inativação do herbicida metribuzin em materiais de um Latossolo e de um Podzólico representativos de duas regiões do Estado de Minas Gerais, em função de diferentes densidades aparentes. Ensaios biológicos foram utilizados para medir a inativação e a mobilidade do metribuzin nos diferentes solos e densidades. A densidade aparente alterou de forma pronunciada a quantidade de herbicida lixiviado através das colunas dos materiais dos solos estudados. Quanto maior a densidade, menor a quantidade de herbicida lixiviado. A quantidade de herbicida que permaneceu biologicamente ativo ao longo da coluna foi diretamente relacionada com a densidade, em cada solo. A mobilidade do metribuzin no material do Latossolo foi maior que no de Podzólico, em consequência de maior atividade coloidal deste.The leaching and inactivation of metribuzin were studied with materials of two mineral soilsat different bulk densities. Plastic tubing of' 7.25 cm diameter and 10 cm height were filled up with different amounts of soil to get different bulk densities. One kg/ha of a.i. of metribuzin placed on the surface are a of the column was le ached through these soil colums using 250 ml of water. The cotyledon disk bioassay method was used to detect the metribuzin leachet. The biological active metribuzin in the soil colunn at different depths, and the inativation abil ity of the soils were determined using the assay with cucumber (Cucumis sativus L. as test-plant. The increase of bulk density reduced the leaching and enhanced the biologically active metribuzin in the soil column. Metribuzin was more mobil in the Red -yellow Lato ssol and more inactivated in the Red-yellow Podzolic soils.

  7. A novel & affordable interactive floor for educational applications

    DEFF Research Database (Denmark)

    Boisen, Ulrik; Hansen, Anders Juul; Knudsen, Lars

    2011-01-01

    This article examines two research areas: How interactive floors can be used beneficially in an educational context, and how an interactive floor can be created which is mobile and relatively inexpensive....

  8. Management of disorders of the posterior pelvic floor.

    Science.gov (United States)

    Berman, Loren; Aversa, John; Abir, Farshad; Longo, Walter E.

    2005-01-01

    INTRODUCTION: Constipation is a relatively common problem affecting 15 percent of adults in the Western world, and over half of these cases are related to pelvic floor disorders. This article reviews the clinical presentation and diagnostic approach to posterior pelvic floor disorders, including how to image and treat them. METHODS: A Pubmed search using keywords "rectal prolapse," "rectocele," "perineal hernia," and "anismus" was performed, and bibliographies of the revealed articles were cross-referenced to obtain a representative cross-section of the literature, both investigational studies and reviews, that are currently available on posterior pelvic floor disorders. DISCUSSION: Pelvic floor disorders can occur with or without concomitant physical anatomical defects, and there are a number of imaging modalities available to detect such abnormalities in order to decide on the appropriate course of treatment. Depending on the nature of the disorder, operative or non-operative therapy may be indicated. CONCLUSION: Correctly diagnosing pelvic floor disorders can be complex and challenging, and the various imaging modalities as well as clinical history and exam must be considered together in order to arrive at a diagnosis. PMID:16720016

  9. Special aspects of attic floor warming in historic buildings

    Directory of Open Access Journals (Sweden)

    Murgul Vera

    2017-01-01

    Full Text Available This article containsreasoningof the heat transfer performance uniformity factor determination for attic floors of historic residential buildings while energy effective modifying buildings. The numeral value of this heat transfer performance uniformity factor for the wooden attic floor structure was founddurung investigation. It was estimated that there was no moisture condensation in the wooden attic floor structure.

  10. Short communication: Flooring preferences of dairy cows at calving.

    Science.gov (United States)

    Campler, M; Munksgaard, L; Jensen, M B; Weary, D M; von Keyserlingk, M A G

    2014-02-01

    The present study investigated the flooring preference during the 30 h before parturition in Holstein dairy cows housed individually in a maternity pen. Seventeen multiparous cows were moved, on average, 2 d before expected calving date into an individual maternity pen with 3 different flooring surfaces: 10 cm of sand, pebble-top rubber mats, or concrete flooring, each covered with 15 cm of straw. Calving location, lying time, and total time and number of lying bouts on each of the floor types were recorded during 2 periods: precalving (24 to 29 h before calving) and at calving (0 to 5h before calving). Ten cows calved on sand, 6 on concrete, and 1 on the rubber mat. Lying bouts increased during the hours closest to calving, regardless of flooring. The number of lying bouts did not differ between flooring types precalving but cows had more lying bouts on sand and concrete compared with rubber at calving. Cows spent more time lying down on sand and concrete compared with rubber precalving, but lying times did not differ between treatments at calving. Cows that calved on sand spent more time lying on sand at calving compared with the other 2 flooring types. Cows that calved on concrete did not show a flooring preference at calving. These results indicate that rubber mats are the least preferred by dairy cows in the maternity pens, even when covered with a deep layer of straw. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  11. Obtaining and Estimating Low Noise Floors in Vibration Sensors

    DEFF Research Database (Denmark)

    Brincker, Rune; Larsen, Jesper Abildgaard

    2007-01-01

    For some applications like seismic applications and measuring ambient vibrations in structures, it is essential that the noise floors of the sensors and other system components are low and known to the user. Some of the most important noise sources are reviewed and it is discussed how the sensor...... can be designed in order to obtain a low noise floor. Techniques to estimate the noise floors for sensors are reviewed and are demonstrated on a commercial commonly used sensor for vibration testing. It is illustrated how the noise floor can be calculated using the coherence between simultaneous...

  12. CAISSON TYPE HOLLOW FLOOR SLABS OF MONOLITHIC MULTI-STOREYED BUILDINGS

    Directory of Open Access Journals (Sweden)

    Malakhova Anna Nikolaevna

    2016-06-01

    Full Text Available One of the disadvantages of building structures made of reinforced concrete is their considerable weight. One of the trends to decrease the weight of concrete structures, including floor slabs, is the arrangement of voids in the cross-sectional building structures. In Russian and foreign practice paper, cardboard and plastic tubes has been used for creation of voids in the construction of monolithic floor slabs. Lightweight concretes were also used for production of precast hollow core floor slabs. The article provides constructive solutions of precast hollow core floor slabs and solid monolithic slabs that were used in the construction of buildings before wide use of large precast hollow core floor slabs. The article considers the application of caisson hollow core floor slabs for modern monolithic multi-storeyed buildings. The design solutions of such floor slabs, experimental investigations and computer modeling of their operation under load were described in this article. The comparative analysis of the calculation results of computer models of a hollow slabs formed of rod or plastic elements showed the similarity of calculation results.

  13. Bulk substrate porosity verification by applying Monte Carlo modeling and Castaing's formula using energy-dispersive x-rays

    Science.gov (United States)

    Yung, Lai Chin; Fei, Cheong Choke; Mandeep, Jit Singh; Amin, Nowshad; Lai, Khin Wee

    2015-11-01

    The leadframe fabrication process normally involves additional thin-metal layer plating on the bulk copper substrate surface for wire bonding purposes. Silver, tin, and copper flakes are commonly adopted as plating materials. It is critical to assess the density of the plated metal layer, and in particular to look for porosity or voids underneath the layer, which may reduce the reliability during high-temperature stress. A fast, reliable inspection technique is needed to assess the porosity or void weakness. To this end, the characteristics of x-rays generated from bulk samples were examined using an energy-dispersive x-ray (EDX) detector to examine the porosity percentage. Monte Carlo modeling was integrated with Castaing's formula to verify the integrity of the experimental data. Samples with different porosity percentages were considered to test the correlation between the intensity of the collected x-ray signal and the material density. To further verify the integrity of the model, conventional cross-sectional samples were also taken to observe the porosity percentage using Image J software measurement. A breakthrough in bulk substrate assessment was achieved by applying EDX for the first time to nonelemental analysis. The experimental data showed that the EDX features were not only useful for elemental analysis, but also applicable to thin-film metal layer thickness measurement and bulk material density determination. A detailed experiment was conducted using EDX to assess the plating metal layer and bulk material porosity.

  14. Global floor planning approach for VLSI design

    International Nuclear Information System (INIS)

    LaPotin, D.P.

    1986-01-01

    Within a hierarchical design environment, initial decisions regarding the partitioning and choice of module attributes greatly impact the quality of the resulting IC in terms of area and electrical performance. This dissertation presents a global floor-planning approach which allows designers to quickly explore layout issues during the initial stages of the IC design process. In contrast to previous efforts, which address the floor-planning problem from a strict module placement point of view, this approach considers floor-planning from an area planning point of view. The approach is based upon a combined min-cut and slicing paradigm, which ensures routability. To provide flexibility, modules may be specified as having a number of possible dimensions and orientations, and I/O pads as well as layout constraints are considered. A slicing-tree representation is employed, upon which a sequence of traversal operations are applied in order to obtain an area efficient layout. An in-place partitioning technique, which provides an improvement over previous min-cut and slicing-based efforts, is discussed. Global routing and module I/O pin assignment are provided for floor-plan evaluation purposes. A computer program, called Mason, has been developed which efficiently implements the approach and provides an interactive environment for designers to perform floor-planning. Performance of this program is illustrated via several industrial examples

  15. Pelvic floor dysfunction, and effects of pregnancy and mode of delivery on pelvic floor

    Directory of Open Access Journals (Sweden)

    Murat Bozkurt

    2014-12-01

    Full Text Available Pelvic floor dysfunction (PFD, although seems to be simple, is a complex process that develops secondary to multifactorial factors. The incidence of PFD is increasing with increasing life expectancy. PFD is a term that refers to a broad range of clinical scenarios, including lower urinary tract excretory and defecation disorders, such as urinary and anal incontinence, overactive bladder, and pelvic organ prolapse, as well as sexual disorders. It is a financial burden on the health care system and disrupts women's quality of life. Strategies applied to decrease PFD are focused on the course of pregnancy, mode and management of delivery, and pelvic exercise methods. Many studies in the literature define traumatic birth, usage of forceps, length of the second stage of delivery, and sphincter damage as modifiable risk factors for PFD. Maternal age, fetal position, and fetal head circumference are nonmodifiable risk factors. Although numerous studies show that vaginal delivery affects pelvic floor structures and their functions in a negative way, there is not enough scientific evidence to recommend elective cesarean delivery in order to prevent development of PFD. PFD is a heterogeneous pathological condition, and the effects of pregnancy, vaginal delivery, cesarean delivery, and possible risk factors of PFD may be different from each other. Observational studies have identified certain obstetrical exposures as risk factors for pelvic floor disorders. These factors often coexist; therefore, the isolated effects of these variables on the pelvic floor are difficult to study. The routine use of episiotomy for many years in order to prevent PFD is not recommended anymore; episiotomy should be used in selected cases, and the mediolateral procedures should be used if needed.

  16. Recent progress in material technology on RE-Ba-Cu-O bulk superconductors

    International Nuclear Information System (INIS)

    Teshima, Hidekazu; Morita, Mitsuru

    2011-01-01

    The current status of large-grained RE-Ba-Cu-O (RE: Y or rare earth elements) bulk superconductors with excellent superconducting properties is described. Gd-Ba-Cu-O bulk superconductors can trap a very high magnetic field even if they are melt-processed in air. Although the electromagnetic force caused by the trapped field is larger for a larger sample and may break the sample, a large sample of Gd-Ba-Cu-O 46 mm in diameter has the potential of trapped magnetic fields greater than 10 T at around 40 K. In addition, single-grained bulk superconductors as large as 150 mm can be obtained using the RE compositional gradient method. Dy-Ba-Cu-O is an ideal material for current leads because it has low thermal conductivity and high critical current density at 77 K in high magnetic fields. Eu-Ba-Cu-O has low magnetic permeability, and is therefore suitable for bulk NMR applications. Progress in machining technology has made possible various bulk superconductors with complicated shapes such as coils, leading to small and strong electromagnets by stacking several coil-shaped bulk superconductors together. (author)

  17. Bulk solitary waves in elastic solids

    Science.gov (United States)

    Samsonov, A. M.; Dreiden, G. V.; Semenova, I. V.; Shvartz, A. G.

    2015-10-01

    A short and object oriented conspectus of bulk solitary wave theory, numerical simulations and real experiments in condensed matter is given. Upon a brief description of the soliton history and development we focus on bulk solitary waves of strain, also known as waves of density and, sometimes, as elastic and/or acoustic solitons. We consider the problem of nonlinear bulk wave generation and detection in basic structural elements, rods, plates and shells, that are exhaustively studied and widely used in physics and engineering. However, it is mostly valid for linear elasticity, whereas dynamic nonlinear theory of these elements is still far from being completed. In order to show how the nonlinear waves can be used in various applications, we studied the solitary elastic wave propagation along lengthy wave guides, and remarkably small attenuation of elastic solitons was proven in physical experiments. Both theory and generation for strain soliton in a shell, however, remained unsolved problems until recently, and we consider in more details the nonlinear bulk wave propagation in a shell. We studied an axially symmetric deformation of an infinite nonlinearly elastic cylindrical shell without torsion. The problem for bulk longitudinal waves is shown to be reducible to the one equation, if a relation between transversal displacement and the longitudinal strain is found. It is found that both the 1+1D and even the 1+2D problems for long travelling waves in nonlinear solids can be reduced to the Weierstrass equation for elliptic functions, which provide the solitary wave solutions as appropriate limits. We show that the accuracy in the boundary conditions on free lateral surfaces is of crucial importance for solution, derive the only equation for longitudinal nonlinear strain wave and show, that the equation has, amongst others, a bidirectional solitary wave solution, which lead us to successful physical experiments. We observed first the compression solitary wave in the

  18. Laparoscopic Pelvic Floor Repair Using Polypropylene Mesh

    Directory of Open Access Journals (Sweden)

    Shih-Shien Weng

    2008-09-01

    Conclusion: Laparoscopic pelvic floor repair using a single piece of polypropylene mesh combined with uterosacral ligament suspension appears to be a feasible procedure for the treatment of advanced vaginal vault prolapse and enterocele. Fewer mesh erosions and postoperative pain syndromes were seen in patients who had no previous pelvic floor reconstructive surgery.

  19. Bianchi type-VIh string cloud cosmological models with bulk viscosity

    Science.gov (United States)

    Tripathy, Sunil K.; Behera, Dipanjali

    2010-11-01

    String cloud cosmological models are studied using spatially homogeneous and anisotropic Bianchi type VIh metric in the frame work of general relativity. The field equations are solved for massive string cloud in presence of bulk viscosity. A general linear equation of state of the cosmic string tension density with the proper energy density of the universe is considered. The physical and kinematical properties of the models have been discussed in detail and the limits of the anisotropic parameter responsible for different phases of the universe are explored.

  20. Calculated Bulk Properties of the Actinide Metals

    DEFF Research Database (Denmark)

    Skriver, Hans Lomholt; Andersen, O. K.; Johansson, B.

    1978-01-01

    Self-consistent relativistic calculations of the electronic properties for seven actinides (Ac-Am) have been performed using the linear muffin-tin orbitals method within the atomic-sphere approximation. Exchange and correlation were included in the local spin-density scheme. The theory explains...... the variation of the atomic volume and the bulk modulus through the 5f series in terms of an increasing 5f binding up to plutonium followed by a sudden localisation (through complete spin polarisation) in americium...

  1. Empirical observations offer improved estimates of forest floor carbon content across in the United States

    Science.gov (United States)

    Perry, C. H.; Domke, G. M.; Walters, B. F.; Smith, J. E.; Woodall, C. W.

    2014-12-01

    The Forest Inventory and Analysis (FIA) program of the United States Forest Service reports official estimates of national forest floor carbon (FFC) stocks and stock change to national and international parties, the US Environmental Protection Agency (USEPA) and the United Nations Framework Convention on Climate Change (UNFCCC), respectively. These estimates of national FFC stocks are derived from plot-level predictions of FFC density. We suspect the models used to predict plot-level FFC density are less than ideal for several reasons: (a) they are based upon local studies that may not reflect FFC dynamics at the national scale, (b) they are relatively insensitive to climate change, and (c) they reduce the natural variability of the data leading to misplaced confidence in the estimates. However, FIA has measured forest floor attributes since 2001 on a systematic 1/16th subset of a nation-wide array of inventory plots (7 800 of 125 000 plots). Here we address the efficacy of replacing plot-level model predictions with empirical observations of FFC density while assessing the impact of imputing FFC density values to the full plot network on national stock estimates. First, using an equivalence testing framework, we found model predictions of FFC density to differ significantly from the observations in all regions and forest types; the mean difference across all plots was 21 percent (1.81 Mg·ha-1). Furthermore, the model predictions were biased towards the lower end of extant FFC density observations, underestimating it while greatly truncating the range relative to the observations. Second, the optimal imputation approach (k-Nearest Neighbor, k-NN) resulted in values that were equivalent to observations of FFC density across a range of simulated missingness and maintained the high variability seen in the observations. We used the k-NN approach to impute FFC density values to the 94 percent of FIA inventory plots without soil measurements. Third, using the imputed

  2. Detection of lunar floor-fractured craters using machine learning methods

    Science.gov (United States)

    Thorey, C.

    2015-10-01

    About 200 Floor Fractured Craters (FFCs) have been identified by Schultz (1976) on the Moon, mainly around the lunar maria. These craters are a class of impact craters that are distinguished by having radi-ally and concentric floor-fractured networks and ab-normally shallow floors. In some cases, the uplift of the crater floor can be as large as 50% of the initial crater depth. These impact craters are interpreted to have undergone endogenous deformations after their formation.

  3. 29 CFR 1910.23 - Guarding floor and wall openings and holes.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 5 2010-07-01 2010-07-01 false Guarding floor and wall openings and holes. 1910.23 Section... floor and wall openings and holes. (a) Protection for floor openings. (1) Every stairway floor opening... opening and hole shall be guarded by a standard skylight screen or a fixed standard railing on all exposed...

  4. The importance of bulk density determination in gravity data processing for structure interpretation

    Science.gov (United States)

    Wildan, D.; Akbar, A. M.; Novranza, K. M. S.; Sobirin, R.; Permadi, A. N.; Supriyanto

    2017-07-01

    Gravity method use rock density variation for determining subsurface lithology and geological structure. In the "green area" where measurement of rock density has not been done, an attemp to find density is usually performed by calculating using Parasnis method, or by using using the average of rock density in the earth's crust (2,67 gr/cm3) or by using theoritical value of dominant rock density in the survey area (2,90 gr/cm3). Those three values of densities are applied to gravity data analysis in the hilly "X" area. And we have compared all together in order to observed which value has represented the structure better. The result showed that the higher value of rock density, the more obvious structure in the Bouguer anomaly profile. It is due to the contrast of maximum and minimum value of Bouguer anomaly that will affect the exageration in distance vs Bouguer anomaly graphic.

  5. 40 CFR 427.70 - Applicability; description of the asbestos floor tile subcategory.

    Science.gov (United States)

    2010-07-01

    ... asbestos floor tile subcategory. 427.70 Section 427.70 Protection of Environment ENVIRONMENTAL PROTECTION... Asbestos Floor Tile Subcategory § 427.70 Applicability; description of the asbestos floor tile subcategory... manufacture of asbestos floor tile. ...

  6. An education program about pelvic floor muscles improved women's knowledge but not pelvic floor muscle function, urinary incontinence or sexual function: a randomised trial.

    Science.gov (United States)

    de Andrade, Roberta Leopoldino; Bø, Kari; Antonio, Flavia Ignácio; Driusso, Patricia; Mateus-Vasconcelos, Elaine Cristine Lemes; Ramos, Salvador; Julio, Monica Pitanguy; Ferreira, Cristine Homsi Jorge

    2018-04-01

    Does an educational program with instructions for performing 'the Knack' improve voluntary contraction of the pelvic floor muscles, reduce reports of urinary incontinence, improve sexual function, and promote women's knowledge of the pelvic floor muscles? Randomised, controlled trial with concealed allocation, intention-to-treat analysis and blinded assessors. Ninety-nine women from the local community. The experimental group (n=50) received one lecture per week for 4 weeks, and instructions for performing 'the Knack'. The control group (n=49) received no intervention. The primary outcome was maximum voluntary contraction of the pelvic floor muscles measured using manometry. Secondary outcomes were: ability to contract the pelvic floor muscles measured using vaginal palpation; severity of urinary incontinence measured by the International Consultation on Incontinence Questionnaire-Short Form (ICIQ-SF) scored from 0 to 21; self-reported sexual function; and knowledge related to the pelvic floor. Outcomes were measured at baseline and after 4 weeks. The intervention did not significantly improve: maximum voluntary contraction (MD 2.7 cmH 2 O higher in the experimental group, 95% CI -0.5 to 5.9); ability to contract the pelvic floor muscles (RR 2.18, 95% CI 0.49 to 9.65); or self-reported severity of urinary incontinence (MD 1 point greater reduction in the experimental group, 95% CI -3 to 1). Sexual function did not significantly differ between groups, but very few of the women engaged in sexual activity during the study period. The educational program did, however, significantly increase women's knowledge related to the location, functions and dysfunctions of the pelvic floor muscles, and treatment options. Education and teaching women to perform 'the Knack' had no significant effect on voluntary contraction of the pelvic floor muscles, urinary incontinence or sexual function, but it promoted women's knowledge about the pelvic floor. Brazilian Registry of Clinical

  7. Generation of floor response spectra for PFBR RCB

    International Nuclear Information System (INIS)

    Sajish, S.D.; Ramakrishna, V.; Chellapandi, P.; Chetal, S.C.

    2003-01-01

    This paper describes the generation of floor time histories and corresponding floor response spectrums at various locations in reactor containment building (RCB) for 500 MWe Prototype Fast Breeder Reactor (PFBR). The RCB and its internal structures are modeled with equivalent 3D-beam elements (stick model), which have got the essential global stiffness and inertial properties of the corresponding building. The main aspect in the simulation of beam model is derivation of equivalent cross sectional properties such as bending, torsional and shear rigidities including shear centers. These properties have been obtained through 3D plate/shell element models with appropriate kinematic constraints, for the zones between floors of corresponding buildings. The stick model includes a set of springs and dampers to simulate soil effects, on which base raft and various sticks are mounted. The soil stiffness and damping values are derived based on equations given in ASCE-98. Time history analysis has been done using three uncorrelated time histories, which are derived from the site dependent design response spectra. Floor time histories (FTH) are extracted at important locations from which the corresponding floor response spectrums (FRS) have been generated for various damping values. Peak broadening of the response spectrums has been done according ASCE criteria. Floor response spectrum corresponds to reactor assembly support shows amplification 2.5 for SSE and 3 for OBE. CASTEM 3M is used for seismic analysis and generation of FRS. (author)

  8. Portable flooring protects finished surfaces, is easily moved

    Science.gov (United States)

    Carmody, R. J.

    1964-01-01

    To protect curved, finished surface and provide support for workmen, portable flooring has been made from rigid plastic foam blocks, faced with aluminum strips. Held together by nylon webbing, the flooring can be rolled up for easy carrying.

  9. Dance floors as injury risk: analysis and evaluation of acute injuries caused by dance floors in professional dance with regard to preventative aspects.

    Science.gov (United States)

    Wanke, Eileen M; Mill, Helmgard; Wanke, Alice; Davenport, Jaqueline; Koch, Franziska; Groneberg, David A

    2012-09-01

    A dance floor is often the only support of movements in dance. A dance floor surface that shows deficiencies, can result in acute injuries and chronic problems. Although the significance of an adequate dance floor is well known, there is still a lack of differentiated analyses of dance floor-related acute injuries. This study presents data on acute injuries exclusively caused by the dance floor. The data were obtained from standardized work accident reports from consultants (F 1000), documentary accident records from all Berlin theatres, a state ballet school (n=2,281), and case records from the Berlin State Accident Insurance (UKB) covering a period of 17 years. All analyses and descriptive statistics were conducted with Excel 2007 and SPSS 18. Dance floor surfaces were the causative factor in 12.8% of all accidents (n=291, female 183, male 108). Almost two thirds (62.6%) of all accidents in professional dancers happened on stage, and almost half (49.5%) occurred during performances. As for causative factors, 53.1% of the professional dancers (P) and 42.5% of the dance students (S) claimed that the floor had been "too slippery," with "getting stuck" or (tripping) as the second most common problem (P 18.4%, S 11.3%). Of the injured dancers, 41.8% were older than 30 years and can therefore be categorized as experienced. Dance floors play a significant role in the occurrence of acute injuries, even in experienced dancers. Performances on stage seem to be a particular risk. However, injury prevention measures should include all work locations (P) as well as non-dance-specific locations (S).

  10. Power balance in ELMO Bumpy Torus: bulk electrons and ions in a 37 kW discharge

    International Nuclear Information System (INIS)

    McNeill, D.H.

    1985-10-01

    The power balance of the bulk electrons and ions in discharges with 37 kW of applied microwave power in the ELMO Bumpy Torus (EBT) is examined in a zero-dimensional model using data on the intensity and linewidth of the molecular and atomic hydrogen emission. At least 60% of the applied power is ultimately dissipated by processes involving the neutral particles, including dissociation of molecules, ionization of and radiation from atoms, and heating of cold electrons produced during atomic ionization. The molecular influx rate and the density of atoms are used independently to determine the bulk electron particle confinement time, and an upper bound estimate is made of the diffusional power loss from the bulk plasma electrons. Parameters derived from the basic spectroscopic data presented in this paper include the neutral atom density 2 - 5x10 10 cm -3 , incident molecular flux 3 - 5x10 15 cm -2 s -1 , bulk ion temperature approx. =3 eV, and particle confinement time <1.1 ms. The bulk electron energy confinement time is 0.7 ms or less in the standard operating regime. Published data on the nonthermal electron and ion populations in the plasma are used to evaluate approximately the overall energy flow in the discharge. 54 refs

  11. Evaluation of residual uranium contamination in the dirt floor of an abandoned metal rolling mill.

    Science.gov (United States)

    Glassford, Eric; Spitz, Henry; Lobaugh, Megan; Spitler, Grant; Succop, Paul; Rice, Carol

    2013-02-01

    A single, large, bulk sample of uranium-contaminated material from the dirt floor of an abandoned metal rolling mill was separated into different types and sizes of aliquots to simulate samples that would be collected during site remediation. The facility rolled approximately 11,000 tons of hot-forged ingots of uranium metal approximately 60 y ago, and it has not been used since that time. Thirty small mass (≈ 0.7 g) and 15 large mass (≈ 70 g) samples were prepared from the heterogeneously contaminated bulk material to determine how measurements of the uranium contamination vary with sample size. Aliquots of bulk material were also resuspended in an exposure chamber to produce six samples of respirable particles that were obtained using a cascade impactor. Samples of removable surface contamination were collected by wiping 100 cm of the interior surfaces of the exposure chamber with 47-mm-diameter fiber filters. Uranium contamination in each of the samples was measured directly using high-resolution gamma ray spectrometry. As expected, results for isotopic uranium (i.e., U and U) measured with the large-mass and small-mass samples are significantly different (p 0.05) from results for the large- or small-mass samples. Large-mass samples are more reliable for characterizing heterogeneously distributed radiological contamination than small-mass samples since they exhibit the least variation compared to the mean. Thus, samples should be sufficiently large in mass to insure that the results are truly representative of the heterogeneously distributed uranium contamination present at the facility. Monitoring exposure of workers and the public as a result of uranium contamination resuspended during site remediation should be evaluated using samples of sufficient size and type to accommodate the heterogeneous distribution of uranium in the bulk material.

  12. 27 CFR 46.195 - Floor stocks requirements.

    Science.gov (United States)

    2010-04-01

    ... Tubes Held for Sale on April 1, 2009 General § 46.195 Floor stocks requirements. (a) Take inventory. The dealer must establish the quantity of articles subject to the floor stocks tax held for sale on April 1, 2009. The dealer may take a physical inventory or may use a record (book) inventory, as specified in...

  13. [Quality of life in women with pelvic floor dysfunction].

    Science.gov (United States)

    Segedi, Ljiljana Mladenović; Ilić, Katarina Parezanović; Curcić, Aleksandar; Visnjevac, Nemanja

    2011-11-01

    Pelvic floor dysfunction is a frequent problem affecting more than 50% of women in peri- and postmenopause. Considering that ageing and menopause befall in the significant factors causing this issue, as well as the expected longevity of women in the world and in our country, pelvic floor dysfunction prevelence is foreseen to be even higher. The aim of the study was to evaluate impact of the symptoms of pelvic dysfunction on quality of life and examine body image satisfaction in adult women with pelvic organ prolapse presenting to tertiary care clinic for surgical treatment. This prospective case-control study included 50 patients who presented to tertiary care gynecology clinic for surgical treatment and 50 controls with normal pelvic floor support and without urinary incontinence who presented tertiary care gynecology clinic for other reasons. Both, patients and controls, completed two quastionnaires recommended for the evaluation of symptoms (Pelvic floor distress inventory - short forms) and quality of life impact (Pelvic floor impact questionnaire - short form) of pelvic organ prolapse, and Body Image Scale. The patients scored significantly worse on the prolapse, urinary, colorectal scales and overall score of Pelvic floor distress inventory--20 than controls subjects (134.91 vs 78.08; p self-conscious (78% vs 42%; p body. There was a positive correlation between decreased quality of life and body image in women with pelvic dysfunction. Women with pelvic floor dysfunction have decreased quality of life and body image.

  14. Development of automatic smear testing sampler for radioactive contamination of floor in nuclear power plant

    International Nuclear Information System (INIS)

    Nozawa, Katsuro; Hashimoto, Hiroshi; Shinohara, Yohtaro; Iwaki, Kiyotaka

    1980-01-01

    The floor contamination with radioactive substances in the controlled area of nuclear power stations is strictly controlled, and it is tested by the smear method, wiping the contaminants on floors with filter papers or cloths and measuring the radioactive intensity to obtain contamination density. The works are very laborious, therefore the automatic smear sampler was developed. Simple operation, shortening of time required for wiping, constant and high efficiency of wiping, and easy numbering of samples were the aims in the development. The method of wiping, the mechanisms of wiping, cloth feeding and running, the surface pressure at the time of wiping, the number of times of wiping and required motor torque were studied. The outline of the developed sampler is explained. The performance of the sampler was compared with manual wiping. The efficiency of wiping with the sampler was 92%, assuming manual wiping as 100. Difference was not observed between careful manual wiping and the wiping with the sampler, therefore it was confirmed that this automatic floor smear sampler can be put in practical use. By conventional manual sampling, the maximum limit was about 400 samples/man-day, but when this sampler is used, about 1000 samples/sampler-day is possible. At present, this sampler is operated in Hamaoka Nuclear Power Station. (Kako, I.)

  15. Anonymous electronic trading versus floor trading

    OpenAIRE

    Franke, Günter; Hess, Dieter

    1995-01-01

    This paper compares the attractiveness of floor trading and anonymous electronic trading systems. It is argued that in times of low information intensity the insight into the order book of the electronic trading system provides more valuable information than floor trading, but in times of high information intensity the reverse is true. Thus, the electronic system's market share in trading activity should decline in times of high information intensity. This hypothesis is tested by data on BUND...

  16. Effect of slatted and solid floors and permeability of floors in pig houses on environment, animal welfare and health and food safety: a review of literature

    NARCIS (Netherlands)

    Vermeij, I.; Enting, J.; Spoolder, H.A.M.

    2009-01-01

    An integrated approach can improve understanding of floor performance. Not only gap width or percentage of slatted floor is important, but a minimum percentage of permeability of the total floor area appears to be decisive

  17. Imaging of the posterior pelvic floor

    International Nuclear Information System (INIS)

    Stoker, Jaap; Bartram, Clive I.; Halligan, Steve

    2002-01-01

    Disorders of the posterior pelvic floor are relatively common. The role of imaging in this field is increasing, especially in constipation, prolapse and anal incontinence, and currently imaging is an integral part of the investigation of these pelvic floor disorders. Evacuation proctography provides both structural and functional information for rectal voiding and prolapse. Dynamic MRI may be a valuable alternative as the pelvic floor muscles are visualised, and it is currently under evaluation. Endoluminal imaging is important in the management of anal incontinence. Both endosonography and endoanal MRI can be used for detection of anal sphincter defects. Endoanal MRI has the advantage of simultaneously evaluating external sphincter atrophy, which is an important predictive factor for the outcome of sphincter repair. Many aspects of constipation and prolapse remain incompletely understood and treatment is partly empirical; however, imaging has a central role in management to place patients into treatment-defined groups. (orig.)

  18. Imaging of the posterior pelvic floor

    Energy Technology Data Exchange (ETDEWEB)

    Stoker, Jaap [Department of Radiology, Academic Medical Center, University of Amsterdam (Netherlands); Bartram, Clive I.; Halligan, Steve [Intestinal Imaging Centre, St. Mark' s Hospital, London (United Kingdom)

    2002-04-01

    Disorders of the posterior pelvic floor are relatively common. The role of imaging in this field is increasing, especially in constipation, prolapse and anal incontinence, and currently imaging is an integral part of the investigation of these pelvic floor disorders. Evacuation proctography provides both structural and functional information for rectal voiding and prolapse. Dynamic MRI may be a valuable alternative as the pelvic floor muscles are visualised, and it is currently under evaluation. Endoluminal imaging is important in the management of anal incontinence. Both endosonography and endoanal MRI can be used for detection of anal sphincter defects. Endoanal MRI has the advantage of simultaneously evaluating external sphincter atrophy, which is an important predictive factor for the outcome of sphincter repair. Many aspects of constipation and prolapse remain incompletely understood and treatment is partly empirical; however, imaging has a central role in management to place patients into treatment-defined groups. (orig.)

  19. Predictive multiscale computational model of shoe-floor coefficient of friction.

    Science.gov (United States)

    Moghaddam, Seyed Reza M; Acharya, Arjun; Redfern, Mark S; Beschorner, Kurt E

    2018-01-03

    Understanding the frictional interactions between the shoe and floor during walking is critical to prevention of slips and falls, particularly when contaminants are present. A multiscale finite element model of shoe-floor-contaminant friction was developed that takes into account the surface and material characteristics of the shoe and flooring in microscopic and macroscopic scales. The model calculates shoe-floor coefficient of friction (COF) in boundary lubrication regime where effects of adhesion friction and hydrodynamic pressures are negligible. The validity of model outputs was assessed by comparing model predictions to the experimental results from mechanical COF testing. The multiscale model estimates were linearly related to the experimental results (p < 0.0001). The model predicted 73% of variability in experimentally-measured shoe-floor-contaminant COF. The results demonstrate the potential of multiscale finite element modeling in aiding slip-resistant shoe and flooring design and reducing slip and fall injuries. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  20. Common floor system vertical earthquake-proof structure for reactor equipment

    International Nuclear Information System (INIS)

    Morishita, Masaki.

    1996-01-01

    In an LMFBR type reactor, a reactor container, a recycling pump and a heat exchanger are disposed on a common floor. Vertical earthquake-proof devices which can be stretched only in vertical direction formed by laminating large-sized bellevilles are disposed on a concrete wall at the circumference of each of reactor equipments. A common floor is placed on all of the vertical earthquake-proof devices to support the entire earthquake-proof structure simultaneously. If each of reactor equipments is loaded on the common floor and the common floor is entirely supported against earthquakes altogether, since the movement of each of the reactor equipments loaded on the common floor is identical, relative dislocation is not exerted on the main pipelines which connect the equipments. In addition, since the entire earthquake structure has a flat common floor and each of the reactor equipments is suspended to minimize the distance between a gravitational center and a support point, locking vibration is less caused to the horizontal earthquake. (N.H.)

  1. Functional imaging of the pelvic floor

    Energy Technology Data Exchange (ETDEWEB)

    Lienemann, Andreas E-mail: andreaslienemann@web.de; Fischer, Tanja

    2003-08-01

    Introduction/Objective: Pelvic floor dysfunction and associated pelvic organ prolapse represent a major problem in our present-day society, mostly afflicting parous women. Magnetic resonance imaging (MRI) is assuming an increasingly important role in the more accurate delineation of the extent of the problem. This article briefly reviews one of the main radiological methods for the dynamic evaluation of the pelvic floor: functional cine MRI. Methods and Material: Out of the literature the smallest common denominator for functional cine MRI can be defined as follows: high field system; patient either in supine or sitting position; fast gradient echo sequence; midsagittal slice orientation; either a stack of slices or repeated measurements at the same slice position with the patient at rest or straining; image analysis using the pubococcygeal reference line. Results: All except two publications stress the usefulness of functional cine MRI in the evaluation of patients with organ descent and prolapse. This well accepted method allows for the visualization of all relevant structures in the anterior, middle and posterior compartment. It is especially useful in the detection of enteroceles, and provides a reliable postoperative follow-up tool. Isolated urinary or stool incontinence are not an indication for functional cine MRI, as is the case in patients with equivocal clinical findings. To date it does not allow for real 3D imaging of the pelvic floor or sufficient determination of fascial defects. Discussion: Functional cine MRI of the pelvic floor is a promising new imaging method for the detection of organ descent and prolapse in patients with equivocal clinical findings. The combination of function and morphology allows for an innovative view of the pelvic floor, and thus adds to our understanding of the various interactions of the structures.

  2. Modelling floor heating systems using a validated two-dimensional ground coupled numerical model

    DEFF Research Database (Denmark)

    Weitzmann, Peter; Kragh, Jesper; Roots, Peter

    2005-01-01

    This paper presents a two-dimensional simulation model of the heat losses and tempera-tures in a slab on grade floor with floor heating which is able to dynamically model the floor heating system. The aim of this work is to be able to model, in detail, the influence from the floor construction...... the floor. This model can be used to design energy efficient houses with floor heating focusing on the heat loss through the floor construction and foundation. It is found that it is impor-tant to model the dynamics of the floor heating system to find the correct heat loss to the ground, and further......, that the foundation has a large impact on the energy consumption of buildings heated by floor heating. Consequently, this detail should be in focus when designing houses with floor heating....

  3. Do women with pelvic floor dysfunction referred by gynaecologists and urologists at hospitals complete a pelvic floor muscle training programme?

    DEFF Research Database (Denmark)

    Tibaek, Sigrid; Dehlendorff, Christian

    2013-01-01

    For decades women with pelvic floor dysfunction (PFD) have been referred to pelvic floor muscle training (PFMT), but there is only little information on whether the women complete the programmes and why. The objectives of this study were to investigate to which extent women completed a PFMT...

  4. Maximum repulsed magnetization of a bulk superconductor with low pulsed field

    International Nuclear Information System (INIS)

    Tsuchimoto, M.; Kamijo, H.; Fujimoto, H.

    2005-01-01

    Pulsed field magnetization of a bulk high-T c superconductor (HTS) is important technique especially for practical applications of a bulk superconducting magnet. Full magnetization is not obtained for low pulsed field and trapped field is decreased by reversed current in the HTS. The trapped field distribution by repulsed magnetization was previously reported in experiments with temperature control. In this study, repulsed magnetization technique with the low pulsed field is numerically analyzed under assumption of variable shielding current by the temperature control. The shielding current densities are discussed to obtain maximum trapped field by two times of low pulsed field magnetizations

  5. Indoor radon seasonal variability at different floors of buildings

    International Nuclear Information System (INIS)

    De Francesco, S.; Tommasone, F. Pascale; Cuoco, E.; Tedesco, D.

    2010-01-01

    Indoor radon concentrations have been measured with the α track etch integrated method in public buildings in the town of Pietramelara, north-western Campania, Southern Italy. In particular, our measurements were part of an environmental monitoring program originally aimed at assessing the range of seasonal fluctuations in indoor radon concentrations, at various floors of the studied buildings. However, subsequent analysis of the data and its comparison with the meteorological data recorded in the same period has shown an unexpected pattern at the different floors. In this report we present data suggesting that, besides the well-known medium and longterm periodicity, there could also be a differentiation in major meteorological controlling factors at the different floors of the buildings, a fact that does not appear to have been reported previously. While the lower floors proved to be markedly affected by rainfall, for the upper floors, instead, a different behaviour has been detected, which could possibly be related to global solar radiation.

  6. Pelvic floor spasm as a cause of voiding dysfunction.

    Science.gov (United States)

    Kuo, Tricia L C; Ng, L G; Chapple, Christopher R

    2015-07-01

    Pelvic floor disorders can present with lower urinary tract symptoms, bowel, sexual dysfunction, and/or pain. Symptoms of pelvic muscle spasm (nonrelaxing pelvic floor or hypertonicity) vary and can be difficult to recognize. This makes diagnosis and management of these disorders challenging. In this article, we review the current evidence on pelvic floor spasm and its association with voiding dysfunction. To distinguish between the different causes of voiding dysfunction, a video urodynamics study and/or electromyography is often required. Conservative measures include patient education, behavioral modifications, lifestyle changes, and pelvic floor rehabilitation/physical therapy. Disease-specific pelvic pain and pain from pelvic floor spasm needs to be differentiated and treated specifically. Trigger point massage and injections relieves pain in some patients. Botulinum toxin A, sacral neuromodulation, and acupuncture has been reported in the management of patients with refractory symptoms. Pelvic floor spasm and associated voiding problems are heterogeneous in their pathogenesis and are therefore often underrecognized and undertreated; it is therefore essential that a therapeutic strategy needs to be personalized to the individual patient's requirements. Therefore, careful evaluation and assessment of individuals using a multidisciplinary team approach including a trained physical therapist/nurse clinician is essential in the management of these patients.

  7. Endoscopic anatomy of the orbital floor and maxillary sinus.

    Science.gov (United States)

    Moore, Corey C; Bromwich, Matthew; Roth, Kathy; Matic, Damir B

    2008-01-01

    Endoscopic repair of orbital blow-out fractures could become a predictable and efficient treatment alternative to traditional methods. However, maxillary sinus endoscopy provides a complex and disorienting view of the orbital floor. To be a useful and consistent technique for providing access to the orbital floor, specific knowledge of maxillary endoscopic anatomy is required. The purpose of the study was to provide an anatomic description of the orbital floor via the endoscopic approach. Objectives include defining consistent landmarks for use in endoscopic repair of orbital floor fractures. Using 0- and 30-degree rigid endoscopes, 6 fresh cadavers (12 maxillary sinuses) were examined via a standard Caldwell-Luc approach. Computed tomographic scans, plastic molds, and digital images were used to compare observable averages within bony anatomy. Potential bony landmarks were correlated with soft-tissue anatomy in fresh specimens. The maxillary ostium, orbital floor, and lateral ethmoid air cells were visualized, and their structures were described. Observations were made in relation to the anatomy of the orbital floor and maxillary sinus, including fracture pattern and force transmission pathways. An "orbitomaxillary" sinus bony thickening was identified and described for the first time. This study provides the basis for further refinement of surgical technique and opens the door for future clinical trials using endoscopic repair.

  8. Nuclear reactor cavity floor passive heat removal system

    Science.gov (United States)

    Edwards, Tyler A.; Neeley, Gary W.; Inman, James B.

    2018-03-06

    A nuclear reactor includes a reactor core disposed in a reactor pressure vessel. A radiological containment contains the nuclear reactor and includes a concrete floor located underneath the nuclear reactor. An ex vessel corium retention system includes flow channels embedded in the concrete floor located underneath the nuclear reactor, an inlet in fluid communication with first ends of the flow channels, and an outlet in fluid communication with second ends of the flow channels. In some embodiments the inlet is in fluid communication with the interior of the radiological containment at a first elevation and the outlet is in fluid communication with the interior of the radiological containment at a second elevation higher than the first elevation. The radiological containment may include a reactor cavity containing a lower portion of the pressure vessel, wherein the concrete floor located underneath the nuclear reactor is the reactor cavity floor.

  9. Comparison of changes in the mobility of the pelvic floor muscle on during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction

    OpenAIRE

    Jung, Halim; Jung, Sangwoo; Joo, Sunghee; Song, Changho

    2016-01-01

    [Purpose] The purpose of this study was to compare changes in the mobility of the pelvic floor muscle during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction. [Subjects] Thirty healthy adults participated in this study (15 men and 15 women). [Methods] All participants performed a bridge exercise and abdominal curl-up during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction. Pelvic floor mobility...

  10. Validation of the Pelvic Floor Distress Inventory-20 and the Pelvic Floor Impact Questionnaire-7 in Danish women with pelvic organ prolapse

    DEFF Research Database (Denmark)

    Due, Ulla; Brostrøm, Søren; Lose, Gunnar

    2013-01-01

    To translate the Pelvic Floor Distress Inventory-20 (PFDI-20) and the Pelvic Floor Impact Questionnaire-7 (PFIQ-7) and to evaluate their psychometric properties in Danish women with symptomatic pelvic organ prolapse....

  11. Development of rationalized system treating floor drain

    International Nuclear Information System (INIS)

    Nakamura, Yasuyuki; Serizawa, Kenichi; Komatsu, Akihiro; Shimizu, Takayuki

    1998-01-01

    Radioactive liquid wastes generated at BWR plants are collected and treated as required. These days, however, generation of floor drain has deceased and HFF (Hollow Fiber Filter) has experienced a wide applicability to several kinds of liquid wastes. We should consider that the floor drain can be mixed and diluted with equipment drain and be purified by HFF. That enables some of the sumps and long priming pipes to be combined. From this point of view, we have developed a highly rationalized waste liquid system. We have evaluated the applicability of this system after an investigation into the generation and properties of floor drain and equipment drain at the latest BWR'S and an on-site test at a typical BWR. (author)

  12. The role of exciton ionization processes in bulk heterojunction organic photovoltaic cells

    Science.gov (United States)

    Zou, Yunlong; Holmes, Russell

    2015-03-01

    Dissociating photogenerated excitons into their constituent charges is essential for efficient photoconversion in organic semiconductors. Organic photovoltaics cells (OPV) widely adopt a heterojunction architecture where dissociation is facilitated by charge transfer at a donor-acceptor (D-A) interface. Interestingly, recent work on MoOx/C60 Schottky OPVs has demonstrated that excitons in C60 may also undergo bulk-ionization to generate photocurrent, driven by the built-in field at the MoOx/C60 interface. Here, we show that bulk-ionization processes also contribute to the photocurrent in bulk heterojunction (BHJ) OPVs with fullerene-rich compositions. The short-circuit current density (JSC) in a MoOx/C60 Schottky OPVs shows almost no dependence on temperature down to 80 K. This characteristic of bulk-ionization allows the use of temperature-dependent measurements of JSC to distinguish dissociation by bulk-ionization from charge transfer at a D-A interface. For BHJ OPVs constructed using the D-A pairing of boron subphthalocyanine chloride (SubPc)-C60, bulk-ionization is found to contribute >10% of the total photocurrent and >30% of the photocurrent from C60. We further find that fullerene-rich SubPc-C60 BHJ OPVs show a larger open-circuit voltage (VOC) than evenly mixed BHJs due to the presence of bulk-ionization. This talk will examine the dependence of JSC and VOC on the relative fraction of dissociation by charge transfer and bulk-ionization processes.

  13. An education program about pelvic floor muscles improved women’s knowledge but not pelvic floor muscle function, urinary incontinence or sexual function: a randomised trial

    Directory of Open Access Journals (Sweden)

    Roberta Leopoldino de Andrade

    2018-04-01

    Full Text Available Question: Does an educational program with instructions for performing ‘the Knack’ improve voluntary contraction of the pelvic floor muscles, reduce reports of urinary incontinence, improve sexual function, and promote women’s knowledge of the pelvic floor muscles? Design: Randomised, controlled trial with concealed allocation, intention-to-treat analysis and blinded assessors. Participants: Ninety-nine women from the local community. Intervention: The experimental group (n = 50 received one lecture per week for 4 weeks, and instructions for performing ‘the Knack’. The control group (n = 49 received no intervention. Outcome measures: The primary outcome was maximum voluntary contraction of the pelvic floor muscles measured using manometry. Secondary outcomes were: ability to contract the pelvic floor muscles measured using vaginal palpation; severity of urinary incontinence measured by the International Consultation on Incontinence Questionnaire-Short Form (ICIQ-SF scored from 0 to 21; self-reported sexual function; and knowledge related to the pelvic floor. Outcomes were measured at baseline and after 4 weeks. Results: The intervention did not significantly improve: maximum voluntary contraction (MD 2.7 cmH2O higher in the experimental group, 95% CI –0.5 to 5.9; ability to contract the pelvic floor muscles (RR 2.18, 95% CI 0.49 to 9.65; or self-reported severity of urinary incontinence (MD 1 point greater reduction in the experimental group, 95% CI –3 to 1. Sexual function did not significantly differ between groups, but very few of the women engaged in sexual activity during the study period. The educational program did, however, significantly increase women’s knowledge related to the location, functions and dysfunctions of the pelvic floor muscles, and treatment options. Conclusion: Education and teaching women to perform ‘the Knack’ had no significant effect on voluntary contraction of the pelvic floor muscles

  14. Effect of rearing factors on the prevalence of floor eggs, cloacal cannibalism and feather pecking in commercial flocks of loose housed laying hens.

    Science.gov (United States)

    Gunnarsson, S; Keeling, L J; Svedberg, J

    1999-03-01

    1. Effects of rearing conditions on behavioural problems were investigated in a cohort study of commercial flocks of laying hens housed in 2 different loose housing systems. The sample population was 120 385 laying hens from 59 flocks of various hybrids at 21 different farms. 2. Logistic regression modelling was used to test the effects of selected factors on floor eggs, cloacal cannibalism and feather pecking. In addition to early access to perches or litter, models included hybrid, stocking density, group size, housing system, age at delivery, identical housing system at the rearing farm and at the production farm and, in models for floor eggs and cloacal cannibalism, nest area per hen. Odds ratios were calculated from the results of the models to allow risk assessment. 3. No significant correlations were found between the prevalence of floor eggs, cloacal cannibalism and feather pecking. 4. Access to perches from not later than the 4th week of age decreased the prevalence of floor eggs during the period from start-of-lay until 35 weeks of age, odds ratio 0-30 (Pfeather pecking.

  15. Analysis of threshold current of uniaxially tensile stressed bulk Ge and Ge/SiGe quantum well lasers.

    Science.gov (United States)

    Jiang, Jialin; Sun, Junqiang; Gao, Jianfeng; Zhang, Ruiwen

    2017-10-30

    We propose and design uniaxially tensile stressed bulk Ge and Ge/SiGe quantum well lasers with the stress along direction. The micro-bridge structure is adapted for introducing uniaxial stress in Ge/SiGe quantum well. To enhance the fabrication tolerance, full-etched circular gratings with high reflectivity bandwidths of ~500 nm are deployed in laser cavities. We compare and analyze the density of state, the number of states between Γ- and L-points, the carrier injection efficiency, and the threshold current density for the uniaxially tensile stressed bulk Ge and Ge/SiGe quantum well lasers. Simulation results show that the threshold current density of the Ge/SiGe quantum well laser is much higher than that of the bulk Ge laser, even combined with high uniaxial tensile stress owing to the larger number of states between Γ- and L- points and extremely low carrier injection efficiency. Electrical transport simulation reveals that the reduced effective mass of the hole and the small conduction band offset cause the low carrier injection efficiency of the Ge/SiGe quantum well laser. Our theoretical results imply that unlike III-V material, uniaxially tensile stressed bulk Ge outperforms a Ge/SiGe quantum well with the same strain level and is a promising approach for Si-compatible light sources.

  16. PRODUCTION OF HIGH DENSITY PARTICLEBOARD USING MELAMINE-UREA-FORMALDEHYDE RESIN

    Directory of Open Access Journals (Sweden)

    Setsuo Iwakiri

    2005-12-01

    Full Text Available This research was developed aiming to evaluate the effects of board density and melamine-urea-formaldehyde resin onthe properties of particleboard for semi-structural applications. The boards were manufactured with nominal density of 0.65 g/cm³and 0.90 g/cm³ using urea-formaldehyde resin as control and melamine-urea-formaldehyde. The results showed a better dimensionallystability and mechanical properties of the boards manufactured with higher density and MUF resin content. The fine furnish usedfor external layer of particleboard in the industrial process, could be used for high density homogeneous board to semi-strucuturaluses, such as flooring applications.

  17. Competition and habitat selection in a forest-floor small mammal fauna

    Energy Technology Data Exchange (ETDEWEB)

    Dueser, R D [Univ. of Virginia, Charlottesville; Hallett, J G

    1980-01-01

    In a study of habitat exploitation in a forest-floor small mammal community, we have collected habitat and population data for Peromyscus leucopus, Ochrotomys nuttalli, and Tamias striatus. Using multiple regression analysis, researchers estimate the effects of habitat selection and competition on the local distributions of these species during three seasons. Each of the partial regression coefficients relating the density of an independent species to the density of the dependent species is negative. This result indicates that competition is pervasive among these species. Competitive ability and habitat selectivity both increase in the order Peromyscus-Tamias-Ochrotomys. Peromyscus is a poorly competitive habitat generalist, Ochrotomys is a strongly competitive habitat specialist, and Tamias is intermediate in both respects. The competitive hierarchy is stable between seasons. These results both confirm the conclusions reached in previous studies of this small mammal community and suggest the design of experiments to further clarify the mode and consequences of interaction between these species.

  18. Pelvic floor dyssynergia: efficacy of biofeedback training.

    Science.gov (United States)

    Gadel Hak, Nabil; El-Hemaly, Mohamed; Hamdy, Emad; El-Raouf, Ahmed Abd; Atef, Ehab; Salah, Tarek; El-Hanafy, Ehab; Sultan, Ahmad; Haleem, Magdy; Hamed, Hala

    2011-03-01

    Paradoxical contraction of the pelvic floor during attempts to defaecate is described as pelvic floor dyssynergia (anismus). It is a behavioural disorder (no associated morphological or neurological abnormalities); consequently, biofeedback training has been recommended as a behavioural therapy for such a disorder. The aim of the present study was to evaluate long-term satisfaction of patients diagnosed with pelvic floor dyssynergia after biofeedback. Sixty patients (35 females and 25 males) with a mean age of 30±12years and a 4year duration of constipation were included. Forty-five patients had normal colonic transit and 15 patients had slow colonic transit. History, physical examination and barium enema were done to exclude constipation secondary to organic causes. Colonic and pelvic floor functions (colon-transit time, anorectal manometry, EMG and defaecography) were performed before and after biofeedback treatments. Patients were treated on a weekly basis with an average of (6±2) sessions. At the end of sessions, 55 out of 60 patients (91.6%) reported a subjectively overall improvement. Symptoms of dyschezia were reported less frequently after biofeedback. Age and gender were not predictive factors of outcome. No symptoms at initial assessment were predictive for patient's satisfaction but the only factor of predictive value was the diagnosis of anismus and the motivated patient who wanted to continue the sessions. Biofeedback remains a morbidity free, low-cost and effective outpatient therapy for well-motivated patients complaining of functional constipation and diagnosed as pelvic floor dyssynergia. Copyright © 2011 Arab Journal of Gastroenterology. Published by Elsevier Ltd. All rights reserved.

  19. 120 Years of U.S. Residential Housing Stock and Floor Space

    Energy Technology Data Exchange (ETDEWEB)

    Pinto de Moura, Maria C.; Smith, Steven J.; Belzer, David B.

    2015-08-11

    Energy consumption in the residential sector accounts for one-fifth of total U.S. energy consumption and energy-related CO2 emissions. Floor space is a major driver of building energy demand. This paper develops a historical time series of total residential floor space for 1891-2010 and examines the role of socio-economic drivers GDP, population and household size on floor space. Using primarily data from the U.S. Census Bureau, we develop new construction and vintage-disaggregated housing stock for three building types, and address various data inconsistency issues. An examination of the long-term relationship of GDP and total residential floor space shows a remarkably constant trend over the period. While population increases five times over the period, a 50% decrease in household size contributes towards a tenfold increase in the number of housing units and floor space, while average floor space per unit remains surprisingly constant, as a result of housing retirement dynamics. In the last 30 years, however, these trends appear to be changing, as household size shows signs of leveling off, or even increasing again, while average floor space per unit has been increasing. Total residential sector primary energy consumption and floor space show a similar growth trend over the last 60 years.

  20. Bulk and interface dielectric functions: New results within the tight-binding approximation

    International Nuclear Information System (INIS)

    Elvira, V.D.; Duran, J.C.

    1991-01-01

    A tight-binding approach is used to analyze the dielectric behaviour of bulk semiconductors and semiconductor interfaces. This time interactions between second nearest neighbours are taken into account and several electrostatic models are proposed for the induced charge density around the atoms. The bulk dielectric function of different semiconductors (Si, Ge, GaAs and AlAs) are obtained and compared with other theoretical and experimental results. Finally, the energy band offset for GaAs-AlAs(1,0,0) interface is obtained and related to bulk properties of both semiconductors. The results presented in this paper show how the use of very simple but more realistic electrostatic models improve the analysis of the screening properties in semiconductors, giving a new support to the consistent tight-binding method for studying characteristics related to those properties. (Author)

  1. Characterization of pinning stability of HTS Gd123 bulks by using a pulsed-field magnetization

    Energy Technology Data Exchange (ETDEWEB)

    Taguchi, R; Miki, M; Tsuzuki, K; Izumi, M [Department of Marine Electronics and Mechanical Engineering, Tokyo University of Marine Science and Technology, 2-1-6, Etchujima, Koto-ku, Tokyo 135-8533 (Japan); Yamaguchi, K [Sumitomo Heavy Industries Ltd., ThinkPark Tower, 1-1-2, Osaki, Shinagawa-ku, Tokyo 141-6025 (Japan); Kimura, Y [Kawasaki Heavy Industries Ltd., Technical Institute System Technology Development Center, 1-1, Kawasaki-cho, Akashi-shi, Hyogo 673-8666 (Japan); Ida, T, E-mail: m084025@kaiyodai.ac.j [Department of Electronic Control Engineering, Hiroshima National College of Maritime Technology, Toyota-gun, Hiroshima 725-0231 (Japan)

    2010-06-01

    High-temperature superconductor (HTS) Gd-bulks are used for field-pole magnets of rotating machines. We have conducted a study of pulsed-field magnetization (PFM) for the bulks to be magnetized alternatively on the rotor. Performances of HTS bulks have been qualified on the basis of the field-cooling magnetization (FCM). HTS bulks are a kind of crystals containing lots of tiny crystals boundaries. It is difficult to find comparable data between PFM and FCM results, mainly because of the different pinning stability through both processes. We need to assess an effective method of characterization for the flux pinning stability under PFM. We compared two HTS bulks: one shows a flux flow and relatively small trapped flux while the other is magnetized with a little flux instability and a large integrated trapped flux. These Gd123 bulks are 100 mm in diameter and 20 mm in thickness. After applying PFM at the liquid nitrogen temperature, we measured the trapped field density distribution and introduced a new parameter representing the trapped flux instability at each position on the surface of the bulk. We propose a way of visualization of the flux pinning instability of the HTS bulks.

  2. Accurate heterogeneous dose calculation for lung cancer patients without high‐resolution CT densities

    Science.gov (United States)

    Li, Jonathan G.; Liu, Chihray; Olivier, Kenneth R.; Dempsey, James F.

    2009-01-01

    The aim of this study was to investigate the relative accuracy of megavoltage photon‐beam dose calculations employing either five bulk densities or independent voxel densities determined by calibration of the CT Houndsfield number. Full‐resolution CT and bulk density treatment plans were generated for 70 lung or esophageal cancer tumors (66 cases) using a commercial treatment planning system with an adaptive convolution dose calculation algorithm (Pinnacle3, Philips Medicals Systems). Bulk densities were applied to segmented regions. Individual and population average densities were compared to the full‐resolution plan for each case. Monitor units were kept constant and no normalizations were employed. Dose volume histograms (DVH) and dose difference distributions were examined for all cases. The average densities of the segmented air, lung, fat, soft tissue, and bone for the entire set were found to be 0.14, 0.26, 0.89, 1.02, and 1.12 g/cm3, respectively. In all cases, the normal tissue DVH agreed to better than 2% in dose. In 62 of 70 DVHs of the planning target volume (PTV), agreement to better than 3% in dose was observed. Six cases demonstrated emphysema, one with bullous formations and one with a hiatus hernia having a large volume of gas. These required the additional assignment of density to the emphysemic lung and inflammatory changes to the lung, the regions of collapsed lung, the bullous formations, and the hernia gas. Bulk tissue density dose calculation provides an accurate method of heterogeneous dose calculation. However, patients with advanced emphysema may require high‐resolution CT studies for accurate treatment planning. PACS number: 87.53.Tf

  3. 76 FR 7098 - Dealer Floor Plan Pilot Program

    Science.gov (United States)

    2011-02-09

    ... Plan Pilot Program AGENCY: U.S. Small Business Administration (SBA). ACTION: Program implementation with request for comments. SUMMARY: SBA is introducing a new Dealer Floor Plan Pilot Program to make... Plan Pilot Program was created in the Small Business Jobs Act of 2010. Under the new Dealer Floor Plan...

  4. 49 CFR 38.99 - Floors, steps and thresholds.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Floors, steps and thresholds. 38.99 Section 38.99 Transportation Office of the Secretary of Transportation AMERICANS WITH DISABILITIES ACT (ADA) ACCESSIBILITY SPECIFICATIONS FOR TRANSPORTATION VEHICLES Commuter Rail Cars and Systems § 38.99 Floors, steps and thresholds...

  5. Field percolation and high current density in 80/20 DyBa2Cu3O7-x/Dy2BaCuO5 bulk magnetically textured composite ceramics

    International Nuclear Information System (INIS)

    Cloots, R.; Liege Univ.; Dang, A.; Vanderbemden, P.; Vanderschueren, A.; Vanderschueren, H.W.; Bougrine, H.; Liege Univ.; Rulmont, A.; Ausloos, M.

    1996-01-01

    We measured the AC susceptibility of magnetically textured (123) 80%/211(20%) DyBaCuO composite in a special set-up in order to enhance the intergrain contribution. The synthesis process led to very clean weak links at grain boundaries. At the percolation threshold bulk shielding paths were such that the intergrain critical current density J C was above 10 5 A/cm 2 . The field dependence of J C was understood through an analytical form indicating a distribution of currents similar to the law of clusters at fracture/percolation thresholds. (orig.)

  6. Bulk oil clauses

    International Nuclear Information System (INIS)

    Gough, N.

    1993-01-01

    The Institute Bulk Oil Clauses produced by the London market and the American SP-13c Clauses are examined in detail in this article. The duration and perils covered are discussed, and exclusions, adjustment clause 15 of the Institute Bulk Oil Clauses, Institute War Clauses (Cargo), and Institute Strikes Clauses (Bulk Oil) are outlined. (UK)

  7. "Help Me Pull That Cursor" A Collaborative Interactive Floor Enhancing Community Interaction

    Directory of Open Access Journals (Sweden)

    Peter Krogh

    2004-05-01

    Full Text Available In this paper we describe the development, experiments and evaluation of the iFloor, an interactive floor prototype installed at the local central municipality library. The primary purpose of the iFloor prototype is to support and stimulate community interaction between collocated people. The context of the library demands that any user can walk up and use the prototype without any devices or prior introduction. To achieve this, the iFloor proposes innovative interaction (modes/paradigms/patterns for floor surfaces through the means of video tracking. Browsing and selecting content is done in a collaborative process and mobile phones are used for posting messages onto the floor. The iFloor highlights topics on social issues of ubiquitous computing environments in public spaces, and provides an example of how to exploit human spatial movements, positions and arrangements in interaction with computers.

  8. Chemistry of burning the forest floor during the FROSTFIRE experimental burn, interior Alaska, 1999

    Science.gov (United States)

    Harden, J.W.; Neff, J.C.; Sandberg, D.V.; Turetsky, M.R.; Ottmar, R.; Gleixner, G.; Fries, T.L.; Manies, K.L.

    2004-01-01

    Wildfires represent one of the most common disturbances in boreal regions, and have the potential to reduce C, N, and Hg stocks in soils while contributing to atmospheric emissions. Organic soil layers of the forest floor were sampled before and after the FROSTFIRE experimental burn in interior Alaska, and were analyzed for bulk density, major and trace elements, and organic compounds. Concentrations of carbon, nutrients, and several major and trace elements were significantly altered by the burn. Emissions of C, N, and Hg, estimated from chemical mass balance equations using Fe, Al, and Si as stable constituents, indicated that 500 to 900 g C and up to 0 to 4 ?? 10-4 g Hg/M2 were lost from the site. Calculations of nitrogen loss range from -4 to +6 g/m2 but were highly variable (standard deviation 19), with some samples showing increased N concentrations post-burn potentially from canopy ash. Noncombustible major nutrients such as Ca and K also were inherited from canopy ash. Thermogravimetry indicates a loss of thermally labile C and increase of lignin-like C in char and ash relative to unburned counterparts. Overall, atmospheric impacts of boreal fires include large emissions of C, N and Hg that vary greatly as a function of severe fire weather and its access to deep organic layers rich in C, N, and Hg. In terrestrial systems, burning rearranges the vertical distribution of nutrients in fuels and soils, the proximity of nutrients and permafrost to surface biota, and the chemical composition of soil including its nutrient and organic constituents, all of which impact C cycling. Copyright 2004 by the American Geophysical Union.

  9. Densidade global de solos medida com anel volumétrico e por cachimbagem de terra fina seca ao ar Bulk density of soil samples measured in the field and through volume measurement of sieved soil

    Directory of Open Access Journals (Sweden)

    Bernardo Van Raij

    1989-01-01

    Full Text Available Em laboratórios de rotina de fertilidade do solo, a medida de quantidade de terra para análise é feita em volume, mediante utensílios chamados "cachimbos", que permitem medir volumes de terra. Admite-se que essas medidas reflitam a quantidade de terra existente em volume de solo similar em condições de campo. Essa hipótese foi avaliada neste trabalho, por doze amostras dos horizontes A e B de seis perfis de solos. A densidade em condições de campo foi avaliada por anel volumétrico e, no laboratório, por meio de cachimbos de diversos tamanhos. A cachimbagem revelou-se bastante precisa. Os valores de densidade global calculada variaram de 0,63 a 1,46g/cm³ para medidas de campo e de 0,91 a 1,33g/cm³ para medidas com cachimbos. Portanto, a medida de laboratório subestimou valores altos de densidade e deu resultados mais elevados para valores de campo mais baixos.In soil testing laboratories, soil samples for chemical analysis are usually measured by volume, using appropriate measuring spoons. It is tacitly assumed that such measurements would reflect amounts of soil existing in the same volume under field conditions. This hypothesis was tested, using 12 soil samples of the A and B horizons of six soil profiles. Bulk density in the field was evaluated through a cylindrical metal sampler of 50cm³ and in the laboratory using spoons of different sizes. Measurements of soil volumes by spoons were quite precise. Values of bulk density varied between 0.63 and 1.46g/cm³ for field measurements and between 0.91 and 1.33g/cm³ for laboratory measurements with spoons. Thus, laboratory measurements overestimated lower values of bulk densities and underestimated the higher ones.

  10. A Method of Assembling Wall or Floor Elements

    DEFF Research Database (Denmark)

    2002-01-01

    The invention relates to a method of constructing, at the site of use, a building wall (1) or a building floor (1) using a plurality of prefabricated concrete or lightweight concrete plate-shaped wall of floor elements (10), in particular cast elements, which have a front side and a rear side...

  11. Microwave processed bulk and nano NiMg ferrites: A comparative study on X-band electromagnetic interference shielding properties

    Energy Technology Data Exchange (ETDEWEB)

    Chandra Babu Naidu, K., E-mail: chandrababu954@gmail.com [Ceramic Composite Laboratory, Centre for Crystal Growth, SAS, VIT University, Vellore 632014, Tamilnadu (India); Madhuri, W., E-mail: madhuriw12@gmail.com [Ceramic Composite Laboratory, Centre for Crystal Growth, SAS, VIT University, Vellore 632014, Tamilnadu (India); IFW, Leibniz Institute for Solid State and Materials Research, Technische Universität Dresden, 01069 Dresden (Germany)

    2017-02-01

    Bulk and nano Ni{sub 1-x}Mg{sub x}Fe{sub 2}O{sub 4} (x = 0–1) samples were synthesized via microwave double sintering and microwave assisted hydrothermal techniques respectively. The diffraction pattern confirmed the formation of cubic spinel phases in case of both the ferrites. The larger bulk densities were achieved to the bulk than that of nano. In addition, a comparative study on X-band (8.4–12 GHz) electromagnetic interference shielding properties of current bulk and nanomaterials was elucidated. The results showed that the bulk Ni{sub 0.6}Mg{sub 0.4}Fe{sub 2}O{sub 4} composition revealed the highest total shielding efficiency (SE{sub T}) of ∼17 dB. In comparison, the shielding efficiency values of all bulk contents were higher than that of nano because of larger bulk densities. Moreover, the ac-electromagnetic parameters such as electrical conductivity (σ{sub ac}), the respective real (ε′ & μ′) and imaginary parts (ε″ & μ″) of complex permittivity and permeability were investigated as a function of gigahertz frequency. The bulk ferrites of x = 0.4 & 0.6 showed the high ε″ of 10.26 & 6.71 and μ″ of 3.65 & 3.09 respectively at 12 GHz which can work as promising microwave absorber materials. Interestingly, nanoferrites exhibited negative μ″ values at few frequencies due to geometrical effects which improves the microwave absorption. - Highlights: • Bulk and nano NiMg ferrites are prepared by microwave and hydrothermal method. • X-band EMI shielding properties are studied for both bulk and nano ferrites. • Bulk Ni{sub 0.6}Mg{sub 0.4}Fe{sub 2}O{sub 4} revealed the highest SE{sub T} of ∼17 dB at 8.4 GHz. • Bulk x = 0.4 & 0.6 showed the high ε″ and μ″ at 12 GHz for absorber applications.

  12. 120 Years of U.S. Residential Housing Stock and Floor Space.

    Directory of Open Access Journals (Sweden)

    Maria Cecilia P Moura

    Full Text Available Residential buildings are a key driver of energy consumption and also impact transportation and land-use. Energy consumption in the residential sector accounts for one-fifth of total U.S. energy consumption and energy-related CO2 emissions, with floor space a major driver of building energy demands. In this work a consistent, vintage-disaggregated, annual long-term series of U.S. housing stock and residential floor space for 1891-2010 is presented. An attempt was made to minimize the effects of the incompleteness and inconsistencies present in the national housing survey data. Over the 1891-2010 period, floor space increased almost tenfold, from approximately 24,700 to 235,150 million square feet, corresponding to a doubling of floor space per capita from approximately 400 to 800 square feet. While population increased five times over the period, a 50% decrease in household size contributed towards a tenfold increase in the number of housing units and floor space, while average floor space per unit remains surprisingly constant, as a result of housing retirement dynamics. In the last 30 years, however, these trends appear to be changing, as household size shows signs of leveling off, or even increasing again, while average floor space per unit has been increasing. GDP and total floor space show a remarkably constant growth trend over the period and total residential sector primary energy consumption and floor space show a similar growth trend over the last 60 years, decoupling only within the last decade.

  13. Bulk-Fill Resin Composites

    DEFF Research Database (Denmark)

    Benetti, Ana Raquel; Havndrup-Pedersen, Cæcilie; Honoré, Daniel

    2015-01-01

    the restorative procedure. The aim of this study, therefore, was to compare the depth of cure, polymerization contraction, and gap formation in bulk-fill resin composites with those of a conventional resin composite. To achieve this, the depth of cure was assessed in accordance with the International Organization...... for Standardization 4049 standard, and the polymerization contraction was determined using the bonded-disc method. The gap formation was measured at the dentin margin of Class II cavities. Five bulk-fill resin composites were investigated: two high-viscosity (Tetric EvoCeram Bulk Fill, SonicFill) and three low......-viscosity (x-tra base, Venus Bulk Fill, SDR) materials. Compared with the conventional resin composite, the high-viscosity bulk-fill materials exhibited only a small increase (but significant for Tetric EvoCeram Bulk Fill) in depth of cure and polymerization contraction, whereas the low-viscosity bulk...

  14. Comparison between dynamic cystocolpoproctography and dynamic pelvic floor MRI: pros and cons: which is the "functional" examination for anorectal and pelvic floor dysfunction?

    Science.gov (United States)

    Maglinte, Dean D T; Hale, Douglass S; Sandrasegaran, Kumar

    2013-10-01

    "Functional" imaging of anorectal and pelvic floor dysfunction has assumed an important role in the diagnosis and management of these disorders. Although defecography has been widely practiced for decades to evaluate the dynamics of rectal emptying, debate concerning its clinical relevance, how it should be done and interpreted continues. Due to the recognition of the association of defecatory disorders with pelvic organ prolapse in women, the need to evaluate the pelvic floor as a unit has arisen. To meet this need, defecography has been extended to include not only evaluation of defecation disorders but also the rest of the pelvic floor by opacifying the small bowel, vagina, and the urinary bladder. The term "dynamic cystocolpoproctography" (DCP) has been appropriately applied to this examination. Rectal emptying performed with DCP provides the maximum stress to the pelvic floor resulting in complete levator ani relaxation. In addition to diagnosing defecatory disorders, this method of examination demonstrates maximum pelvic organ descent and provides organ-specific quantification of organ prolapse, information that is only inferred by means of physical examination. It has been found to be of clinical value in patients with defecation disorders and the diagnosis of associated prolapse in other compartments that are frequently unrecognized by history taking and the limitations of physical examination. Pelvic floor anatomy is complex and DCP does not show the anatomical details pelvic magnetic resonance imaging (MRI) provides. Technical advances allowing acquisition of dynamic rapid MRI sequences has been applied to pelvic floor imaging. Early reports have shown that pelvic MRI may be a useful tool in pre-operative planning of these disorders and may lead to a change in surgical therapy. Predictions of hypothetical increase cancer incidence and deaths in patients exposed to radiation, the emergence of pelvic floor MRI in addition to questions relating to the

  15. Development of fabrication technique of bulk high superconductor

    International Nuclear Information System (INIS)

    Hong, Gye Won; Kim, Chang Joong; Kim, Ki Baik; Lee, Ho Jin; Lee, Hee Gyoun; Kwon, Sun Chil.

    1997-05-01

    In order to realize the commercial application of HTSC materials, it is necessary to develop the fabrication process of high Tc oxide superconductor materials with desired shape and for practical application and high critical current density as well as good mechanical strength which critical current density as well as good mechanical strength which can withstand high lorenz force generated at high magnetic field. Much studies have been concentrated to develop the fabrication technique for high critical current density but still there are a lot of gap which should be overcome for large scale application of HTSC materials at liquid nitrogen temperature. Recently some new fabrication techniques have been developed for YBCO bulk superconductor with high mechanical strength and critical current density. In this project, plastic extrusion and melt process techniques were studied. The components materials for the current lead and the flywheel application were fabricated and their characteristics were investigated from the view point of microstructure and phase formation during heat treatment process. (author). 64 refs., 59 figs

  16. Chronic pelvic floor dysfunction.

    Science.gov (United States)

    Hartmann, Dee; Sarton, Julie

    2014-10-01

    The successful treatment of women with vestibulodynia and its associated chronic pelvic floor dysfunctions requires interventions that address a broad field of possible pain contributors. Pelvic floor muscle hypertonicity was implicated in the mid-1990s as a trigger of major chronic vulvar pain. Painful bladder syndrome, irritable bowel syndrome, fibromyalgia, and temporomandibular jaw disorder are known common comorbidities that can cause a host of associated muscular, visceral, bony, and fascial dysfunctions. It appears that normalizing all of those disorders plays a pivotal role in reducing complaints of chronic vulvar pain and sexual dysfunction. Though the studies have yet to prove a specific protocol, physical therapists trained in pelvic dysfunction are reporting success with restoring tissue normalcy and reducing vulvar and sexual pain. A review of pelvic anatomy and common findings are presented along with suggested physical therapy management. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Smart Floor with Integrated Triboelectric Nanogenerator As Energy Harvester and Motion Sensor.

    Science.gov (United States)

    He, Chuan; Zhu, Weijun; Chen, Baodong; Xu, Liang; Jiang, Tao; Han, Chang Bao; Gu, Guang Qin; Li, Dichen; Wang, Zhong Lin

    2017-08-09

    A smart floor is demonstrated by integrating a square-frame triboelectric nanogenerator (SF-TENG) into a standard wood floor. The smart floor has two working modes based on two pairs of triboelectric materials: one is purposely chosen polytetrafluoroethylene films and aluminum (Al) balls, and the other is the floor itself and the objects that can be triboelectrically charged, such as basketball, shoe soles, and Scotch tape, etc. Utilizing the Al balls enclosed inside shallow boxes, the smart floor is capable of harvesting vibrational energy and, hence, provides a nonintrusive way to detect sudden falls in elderly people. In addition, when the basketball is bounced repeatedly on the floor, the average output voltage and current are 364 ± 43 V and 9 ± 1 μA, respectively, and 87 serially connected light-emitting diodes can be lit up simultaneously. Furthermore, the friction between the triboelectrically chargeable objects and the floor can also induce an alternating current output in the external circuit without the vibration of the Al balls. Normal human footsteps on the floor produce a voltage of 238 ± 17 V and a current of 2.4 ± 0.3 μA. Therefore, this work presents a smart floor with built-in SF-TENG without compromising the flexibility and stability of the standard wood floor and also demonstrates a way to harvest ambient energy solely by using conventional triboelectric materials in our daily life.

  18. Applications and modelling of bulk HTSs in brushless ac machines

    International Nuclear Information System (INIS)

    Barnes, G.J.

    2000-01-01

    The use of high temperature superconducting material in its bulk form for engineering applications is attractive due to the large power densities that can be achieved. In brushless electrical machines, there are essentially four properties that can be exploited; their hysteretic nature, their flux shielding properties, their ability to trap large flux densities and their ability to produce levitation. These properties translate to hysteresis machines, reluctance machines, trapped-field synchronous machines and linear motors respectively. Each one of these machines is addressed separately and computer simulations that reveal the current and field distributions within the machines are used to explain their operation. (author)

  19. A prospective study of floor surface, shoes, floor cleaning and slipping in US limited-service restaurant workers.

    Science.gov (United States)

    Verma, Santosh K; Chang, Wen Ruey; Courtney, Theodore K; Lombardi, David A; Huang, Yueng-Hsiang; Brennan, Melanye J; Mittleman, Murray A; Ware, James H; Perry, Melissa J

    2011-04-01

    Slips and falls are a leading cause of injury at work. Few studies, however, have systematically examined risk factors of slipping outside the laboratory environment. This study examined the association between floor surface characteristics, slip-resistant shoes, floor cleaning frequency and the risk of slipping in limited-service restaurant workers. 475 workers from 36 limited-service restaurants from three major chains in six states in the USA were recruited to participate in a prospective cohort study of workplace slipping. Kitchen floor surface roughness and coefficient of friction (COF) were measured in eight working areas and then averaged within each restaurant. The use of slip-resistant shoes was determined by examining the participant's shoes and noting the presence of a 'slip-resistant' marking on the sole. Restaurant managers reported the frequency of daily kitchen floor cleaning. Participants reported their slip experience and work hours weekly for up to 12 weeks. The survey materials were made available in three languages: English, Spanish and Portuguese. The associations between rate of slipping and risk factors were assessed using a multivariable negative binomial generalised estimating equation model. The mean of individual slipping rate varied among the restaurants from 0.02 to 2.49 slips per 40 work hours. After adjusting for age, gender, BMI, education, primary language, job tenure and restaurant chain, the use of slip-resistant shoes was associated with a 54% reduction in the reported rate of slipping (95% CI 37% to 64%), and the rate of slipping decreased by 21% (95% CI 5% to 34%) for each 0.1 increase in the mean kitchen COF. Increasing floor cleaning frequency was significantly associated with a decreasing rate of slipping when considered in isolation but not after statistical adjustment for other factors. These results provide support for the use of slip-resistant shoes and measures to increase COF as preventive interventions to reduce slips

  20. Lead exposures from varnished floor refinishing.

    Science.gov (United States)

    Schirmer, Joseph; Havlena, Jeff; Jacobs, David E; Dixon, Sherry; Ikens, Robert

    2012-01-01

    We evaluated the presence of lead in varnish and factors predicting lead exposure from floor refinishing and inexpensive dust suppression control methods. Lead in varnish, settled dust, and air were measured using XRF, laboratory analysis of scrape and wipe samples, and National Institute for Occupational Safety and Health (NIOSH) Method 7300, respectively, during refinishing (n = 35 homes). Data were analyzed using step-wise logistic regression. Compared with federal standards, no lead in varnish samples exceeded 1.0 mg/cm(2), but 52% exceeded 5000 ppm and 70% of settled dust samples after refinishing exceeded 40 μg/ft(2). Refinishing pre-1930 dwellings or stairs predicted high lead dust on floors. Laboratory analysis of lead in varnish was significantly correlated with airborne lead (r = 0.23, p = 0.014). Adding dust collection bags into drum sanders and HEPA vacuums to edgers and buffers reduced mean floor lead dust by 8293 μg Pb/ft(2) (pairborne lead exposures to less than 50 μg/m(3). Refinishing varnished surfaces in older housing produces high but controllable lead exposures.

  1. Surface and Bulk Nanostructuring of Insulators by Ultrashort Laser Pulses

    Science.gov (United States)

    2017-04-05

    non perturbative effects leading to HHG. 15. SUBJECT TERMS Nanostructuring of bulk insulators, sub-picosecond electronic and structural events , photo...time, the charge density oscillations follow the time periodicity of the incident radiation. These transient charge oscillations are exclusively due...As in section II photoexcitation and the dielectric response of laser-irradiated diamond are treated in independent particle approximation based on the

  2. A climate response function explaining most of the variation in the forest floor needle mass and the needle decomposition in pine forests across Europe

    DEFF Research Database (Denmark)

    Kurz-Besson, C.; Coûteaux, M.M.; Berg, Bjørn

    2006-01-01

    The forest floor needle mass and the decomposition rates of pine needle litter in a European climate transect were studied in order to estimate the impact of climate change on forest soil carbon sequestration. Eight pine forests preserved from fire were selected along a climatic latitudinal...... gradient from 40° to 60° N, from Spain and Portugal to Sweden. The forest floor (Oi and Oe layers) was sorted into five categories of increasing decomposition level according to morphological criteria. The needle mass loss in each category was determined using a linear mass density method. The needle...... and a recalcitrant one. NF was correlated with actual evapotranspiration (AET) whereas the decomposition parameters (decomposition rate of the decomposable fraction, first year mass loss, forest floor needle mass, age of the most-decomposed category) were related to a combined response function to climate (CRF...

  3. Effect of product form, compaction, vibration and comminution on energywood bulk density

    Science.gov (United States)

    Tim P. McDonald; Bryce J. Stokes; J.F. McNeel

    1995-01-01

    A study was performed to examine the changes in density of stacked roundwood, chips, and chunks as affected by various compaction treatments. Density of stacked roundwood bolts was tested for the effect of stacking orientation, binding of the stack ends, and species. Stacked bolt wood occupied less than 50 percent of the total rack space for all species, giving final...

  4. Experimental investigation and mechanistic modelling of dilute bubbly bulk boiling

    International Nuclear Information System (INIS)

    Kutnjak, Josip

    2013-01-01

    During evaporation the geometric shape of the vapour is not described using thermodynamics. In bubbly flows the bubble shape is considered spheric with small diameters and changing into various shapes upon growth. The heat and mass transfer happens at the interfacial area. The forces acting on the bubbles depend on the bubble diameter and shape. In this work the prediction of the bubble diameter and/or bubble number density in bulk boiling was considered outside the vicinity of the heat input area. Thus the boiling effects that happened inside the nearly saturated bulk were under investigation. This situation is relevant for nuclear safety analysis concerning a stagnant coolant in the spent fuel pool. In this research project a new experimental set-up to investigate was built. The experimental set-up consists of an instrumented, partly transparent, high and slender boiling container for visual observation. The direct visual observation of the boiling phenomena is necessary for the identification of basic mechanisms, which should be incorporated in the simulation model. The boiling process has been recorded by means of video images and subsequently was evaluated by digital image processing methods, and by that data concerning the characteristics of the boiling process were generated for the model development and validation. Mechanistic modelling is based on the derivation of relevant mechanisms concluded from observation, which is in line with physical knowledge. In this context two mechanisms were identified; the growth/-shrink mechanism (GSM) of the vapour bubbles and sudden increases of the bubble number density. The GSM was implemented into the CFD-Code ANSYS-CFX using the CFX Expression Language (CEL) by calculation of the internal bubble pressure using the Young-Laplace-Equation. This way a hysteresis is realised as smaller bubbles have an increased internal pressure. The sudden increases of the bubble number density are explainable by liquid super

  5. Experimental investigation and mechanistic modelling of dilute bubbly bulk boiling

    Energy Technology Data Exchange (ETDEWEB)

    Kutnjak, Josip

    2013-06-27

    During evaporation the geometric shape of the vapour is not described using thermodynamics. In bubbly flows the bubble shape is considered spheric with small diameters and changing into various shapes upon growth. The heat and mass transfer happens at the interfacial area. The forces acting on the bubbles depend on the bubble diameter and shape. In this work the prediction of the bubble diameter and/or bubble number density in bulk boiling was considered outside the vicinity of the heat input area. Thus the boiling effects that happened inside the nearly saturated bulk were under investigation. This situation is relevant for nuclear safety analysis concerning a stagnant coolant in the spent fuel pool. In this research project a new experimental set-up to investigate was built. The experimental set-up consists of an instrumented, partly transparent, high and slender boiling container for visual observation. The direct visual observation of the boiling phenomena is necessary for the identification of basic mechanisms, which should be incorporated in the simulation model. The boiling process has been recorded by means of video images and subsequently was evaluated by digital image processing methods, and by that data concerning the characteristics of the boiling process were generated for the model development and validation. Mechanistic modelling is based on the derivation of relevant mechanisms concluded from observation, which is in line with physical knowledge. In this context two mechanisms were identified; the growth/-shrink mechanism (GSM) of the vapour bubbles and sudden increases of the bubble number density. The GSM was implemented into the CFD-Code ANSYS-CFX using the CFX Expression Language (CEL) by calculation of the internal bubble pressure using the Young-Laplace-Equation. This way a hysteresis is realised as smaller bubbles have an increased internal pressure. The sudden increases of the bubble number density are explainable by liquid super

  6. Effect of thermal conductivities of shape stabilized PCM on under-floor heating system

    International Nuclear Information System (INIS)

    Cheng, Wenlong; Xie, Biao; Zhang, Rongming; Xu, Zhiming; Xia, Yuting

    2015-01-01

    Highlights: • HCE-SSPCM was prepared and used in under-floor heating system. • Enhancing thermal conductivity improved the efficiency of energy and space. • Too high thermal conductivity over a range was meaningless. • The economic benefits of the phase change energy storage system were the best. - Abstract: A kind of heat conduction-enhanced shape-stabilized PCM (HCE-SSPCM) was utilized in the under-floor heating system for house heating in winter. This system charges heat by using cheap nighttime electricity and provides heating needs throughout all day. The effect of thermal conductivity of the PCM on energy savings and economic benefits of the system were theoretically and experimentally studied. HCE-SSPCM plates, made of (solid paraffin + liquid paraffin)/high density polyethylene/expanded graphite, were introduced to a test room with under-floor heating system. And the operating characteristics of the system were compared with that of the non-phase change energy storage system and the conventional air conditioning system. The results showed that enhancing the thermal conductivity of PCM in a certain range could significantly improve the energy efficiency of the heating system and reduce the thickness of thermal insulating materials. But the improving effect was not obvious when the thermal conductivity was beyond 1.0 W/m K. The phase change energy storage system had a comfortable temperature environment and the best economic benefits among the three different heating types especially when the ratio of peak-valley electric price was high. Therefore, increasing the thermal conductivity of SSPCM will be of great significance for house heating

  7. Dance floor mechanical properties and dancer injuries in a touring professional ballet company.

    Science.gov (United States)

    Hopper, Luke S; Allen, Nick; Wyon, Matthew; Alderson, Jacqueline A; Elliott, Bruce C; Ackland, Timothy R

    2014-01-01

    The mechanical properties of the floors used by dancers have often been suggested to be associated with injury, yet limited etiological evidence is available to support this hypothesis. The dance floors at three theatres regularly used by a touring professional ballet company were mechanically quantified with the aim of comparing floor properties with injury incidence in dancers. Cross sectional. Test points on the floors were quantified in accordance with European Sports Surface Standard protocols for force reduction. Injuries and associated variables occurring within the ballet company dancers during activity on the three floors were recorded by the company's medical staff. An injury was recorded if a dancer experienced an incident that restricted the dancer from performing all normal training or performance activities for a 24 h period. Injuries were delimited to those occurring in the lower limbs or lumbar region during non-lifting tasks. Floor construction varied between venues and a range of floor mechanical properties were observed. None of the floors complied with the range of force reduction values required by the European Sport Surface Standards. The highest injury rate was observed on the floor with the greatest variability of force reduction magnitudes. No difference in injury frequency was observed between the venues with the highest and lowest mean force reduction magnitudes. Professional dancers can be required to perform on floors that may be inadequate for safe dance practice. Intra-floor force reduction variability may have a stronger association with injury risk than mean floor force reduction magnitude. Copyright © 2013 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  8. Poultry rearing on perforated plastic floors and the effect on air quality, growth performance, and carcass injuries-Experiment 1: Thermal Comfort.

    Science.gov (United States)

    de Almeida, Eduardo Alves; Arantes de Souza, Lilian Francisco; Sant'Anna, Aline Cristina; Bahiense, Raphael Nogueira; Macari, Marcos; Furlan, Renato Luis

    2017-09-01

    The present study investigated the use of perforated plastic floors in the rearing of male and female poultry under thermal comfort conditions. The study was conducted in 2 climate chambers, in one was conventional poultry litter (wood shavings) and in the other was a perforated plastic floor. The experimental design was a completely randomized design with the factors wood shavings and plastic floor. In each chamber, the animals were divided into 16 experimental pens (8 with males and 8 with females) with a density of 12 birds/m2. The poultry rearing effect was evaluated in terms of air quality (% concentration of ammonia [NH3] and carbon dioxide [CO2]); broiler performance, e.g., weight gain (kg), feed intake (kg), feed conversion, carcass yield and parts (%), meat production (kg/m2), and viability (% of live birds at d 42); scores of hygiene and mobility; and injuries in the chest, hocks, and footpads. Treatments affected air quality, with higher concentrations of NH3 on d 42 (25 ppm vs. 2 ppm) and CO2 (1,400 ppm vs. 1,000 ppm) for wood shavings than for perforated plastic floor, respectively. Males showed a better performance (weight gain, feed intake and feed conversion) than females on d 42 in both floor types (wood shavings and plastic floor). Males reared on wood shavings showed a higher meet production (35.992 kg/m2) than females (32.257 kg/m2). On the plastic floor, males showed a better viability (100%) than females (94.05%), as well better meet production for males (38.55 kg·m-2) than females (31.64 kg/m2). There was no incidence of breast lesions in any of the studied systems. The birds reared on the plastic floor had better hygiene scores and lower hock injury rates than birds reared in the wood shavings chambers. The results of the present study show that the use of perforated plastic floors in chicken farming is an efficient method, which promotes a better-quality environment, superior production rates, and reduced incidence of injuries.

  9. Dual-stiffness flooring: can it reduce fracture rates associated with falls?

    Science.gov (United States)

    Knoefel, Frank; Patrick, Louise; Taylor, Jodie; Goubran, Rafik

    2013-04-01

    Falls cause significant morbidity and mortality in long term care facilities. Dual-stiffness flooring (DSF) has previously shown promise in reducing such morbidity in experimental models. This study set out to measure the impact of SmartCell flooring on falls-related morbidity in a nursing home. All falls occurring at an Arizona nursing home between July 1, 2008, and December 31, 2010, were reviewed for age, sex, diagnosis of osteoporosis, number of medications, history of previous falls, type of flooring (normal vs DSF), time of day, type of injury, and resulting actions. Fall-related outcomes were compared across room types using chi-square and logistic regression methods. Eighty-two falls on the DSF were compared with 85 falls on the regular floor. There was a tendency for residents falling on DSF to have less bruising and abrasions, while having more redness and cuts. There were 2 fractures on regular flooring (2.4% fracture rate) and none on the DSF flooring (0% fracture rate). The fracture rate of 2.4% of falls on the regular floor is consistent with previous reports in the literature, whereas a 0% rate found on the DSF floor is a clinically significant improvement. This suggests that DSF may be a practical approach for institutions and consumers to reduce fall-related injuries. A larger scale controlled study to confirm these encouraging preliminary findings is warranted. Copyright © 2013 American Medical Directors Association, Inc. Published by Elsevier Inc. All rights reserved.

  10. Waste water purification by magnetic separation technique using HTS bulk magnet system

    International Nuclear Information System (INIS)

    Oka, T.; Kanayama, H.; Tanaka, K.; Fukui, S.; Ogawa, J.; Sato, T.; Ooizumi, M.; Terasawa, T.; Itoh, Y.; Yabuno, R.

    2009-01-01

    We have investigated the feasibility of strong magnetic field generators composed of the high temperature superconducting (HTS) bulk magnet systems to the magnetic separation techniques for the waste water including thin emulsion bearing the cutting oil. Two types of the strong field generators were prepared by the face-to-face HTS bulk magnet systems, which emit the magnetic field density of 1 and 2 T in the open spaces between the magnetic poles activated by the pulsed field magnetization and the field cooling methods, respectively. A couple of water channels containing iron balls were settled in the strong field to trap the magnetized flocks in the waste water. The separation ratios of flocks containing 200 ppm magnetite powder were evaluated with respect to the flow rates of the waste water. The performances of bulk magnet system have kept showing values of around 100% until the flowing rate reached up to 18 l/min. This suggests that the magnetic separation by using bulk magnets is effective for the practical water purification systems.

  11. Trapped magnetic field of a superconducting bulk magnet in high- Tc RE-Ba-Cu-O

    International Nuclear Information System (INIS)

    Fujimoto, Hiroyuki; Yoo, Sang Im; Higuchi, Takamitsu; Nakamura, Yuichi; Kamijo, Hiroki; Nagashima, Ken; Murakami, Masato

    1999-01-01

    Superconducting magnets made of high-T c superconductors are promising for industrial applications. It is well known that REBa 2 Cu 3 O 7-x and LRE (light rare-earth) Ba 2 Cu 3 O 7-x superconductors prepared by melt processes have a high critical current density, J c , at 77 K and high magnetic fields. Therefore, the materials are very prospective for high magnetic field application as a superconducting permanent/bulk magnet with liquid-nitrogen refrigeration. LREBaCuO bulks, compared with REBaCuO bulks, exhibit a larger J c in high magnetic fields and a much improved irreversibility field, H irr , at 77 K. In this study, we discuss the possibility and trapped field properties of a superconducting bulk magnet, as well as the melt processing for bulk superconductors and their characteristic superconducting properties. One of the applications is a superconducting magnet for the future magnetically levitated (Maglev) train

  12. Preparation and magnetic properties of anisotropic bulk MnBi/NdFeB hybrid magnets

    Science.gov (United States)

    Ma, Y. L.; Liu, X. B.; Nguyen, V. V.; Poudyal, N.; Yue, M.; Liu, J. P.

    2016-08-01

    Anisotropic hybrid bulk magnets of MnBi/NdFeB with different composition ratio have been prepared with starting MnBi and Nd2Fe14B powders as well as epoxy resin as a binder in case it is needed to form bulk samples. It has been found that the ratio between the two phases in content has a remarkable influence on the magnetic properties, the thermal stability and the density of the bulk magnets. With increasing MnBi content the binder addition can be reduced. When the MnBi content is larger than 30 wt%, no binder is needed. On the other hand, the coercivity and saturation magnetization were increased significantly with increasing NdFeB content. When the NdFeB content was increased from 0% to 50%, the maximum energy product was enhanced from 4.7 to 10.0 MGOe, respectively. The energy product then decreased gradually with the NdFeB content due to the reduced density of the hybrid magnet. The thermal stability measurements showed that the temperature coefficient of coercivity grew with the MnBi content and became positive with MnBi=80 wt%.

  13. Awareness and timing of pelvic floor muscle contraction, pelvic exercises and rehabilitation of pelvic floor in lifelong premature ejaculation: 5 years experience

    Directory of Open Access Journals (Sweden)

    Giuseppe La Pera

    2014-06-01

    Full Text Available Objectives: To assess the cure rate of patients with premature ejaculation who underwent a treatment involving: 1 awareness of the pelvic floor muscles 2 learning the timing of execution and maintenance of contraction of the pelvic floor muscles during the sensation of the pre-orgasmic phase 3 pelvic floor rehabilitation (bio feed back, pelvic exercises and electrostimulation. Materials and methods: We recruited 78 patients with lifelong premature ejaculation who completed the training. The patients were informed of the role of the pelvic floor. They were taught to carry out the execution and maintenance of contraction of the pelvic floor muscles during the sensation of the pre-orgasmic phase to control the ejaculatory reflex. In order to improve the awareness, the tone and the endurance of the pelvic floor muscles, patients were treated with the rehabilitation of pelvic floor (RPF consisting mainly in biofeedback, pelvic exercises and in some cases also in electro-stimulation (ES. The training was carried out for a period of about 2-6 months with an average of 2-5 visits per cycle. Results: 54% of patients who completed the training were cured of premature ejaculation and learned over time to be able to postpone the ejaculation reflex. In a subgroup of 26 patients was also measured the IELT which on the average increased from < 2 minutes to >10 minutes. The best results occurred mainly in patients aged less than 35 where the cure rate was 65%. There were no side effects. Conclusions: In this study, approximately half of patients with premature ejaculation were cured after applying the above treatment.This therapy, necessitates a fairly long period of time (2-6 months and a great commitment on the part of the patient, nevertheless it can be a valid and effective treatment for patients with premature ejaculation. This treatment makes the patient independent in that he is not bound to specific times for taking medication. Furthermore there are no

  14. Bulk Materials Analysis Using High-Energy Positron Beams

    International Nuclear Information System (INIS)

    Glade, S C; Asoka-Kumar, P; Nieh, T G; Sterne, P A; Wirth, B D; Dauskardt, R H; Flores, K M; Suh, D; Odette, G.R.

    2002-01-01

    This article reviews some recent materials analysis results using high-energy positron beams at Lawrence Livermore National Laboratory. We are combining positron lifetime and orbital electron momentum spectroscopic methods to provide electron number densities and electron momentum distributions around positron annihilation sites. Topics covered include: correlation of positron annihilation characteristics with structural and mechanical properties of bulk metallic glasses, compositional studies of embrittling features in nuclear reactor pressure vessel steel, pore characterization in Zeolites, and positron annihilation characteristics in alkali halides

  15. The architectural foundations for agent-based shop floor control

    DEFF Research Database (Denmark)

    Langer, Gilad; Bilberg, Arne

    1998-01-01

    simulation and cell controlenabling technologies. In order to continuethis research effortnew concepts and theories for shop floor control are investigated.This paper reviews the multi-agent concept aimed at investigatingits potential use in shop floor control systems. The paper willalso include a survey...

  16. The Physical Density of the City—Deconstruction of the Delusive Density Measure with Evidence from Two European Megacities

    Directory of Open Access Journals (Sweden)

    Hannes Taubenböck

    2016-11-01

    Full Text Available Density is among the most important descriptive as well as normative measures in urban research. While its basic concept is generally understandable, approaches towards the density measure are manifold, diverse and of multidimensional complexity. This evolves from differing thematic, spatial and calculative specifications. Consequently, applied density measures are often used in a subjective, non-transparent, unspecific and thus non-comparable manner. In this paper, we aim at a systematic deconstruction of the measure density. Varying thematic, spatial and calculative dimensions show significant influence on the measure. With both quantitative and qualitative techniques of evaluation, we assess the particular influences on the measure density. To do so, we reduce our experiment setting to a mere physical perspective; that is, the quantitative measures building density, degree of soil sealing, floor space density and, more specifically, the density of generic structural classes such as open spaces and highest built-up density areas. Using up-to-date geodata derived from remote sensing and volunteered geographic information, we build upon high-quality spatial information products such as 3-D city models. Exemplified for the comparison of two European megacities, namely Paris and London, we reveal and systemize necessary variables to be clearly defined for meaningful conclusions using the density measure.

  17. Assessment of soil sample quality used for density evaluations through computed tomography

    International Nuclear Information System (INIS)

    Pires, Luiz F.; Arthur, Robson C.J.; Bacchi, Osny O.S.

    2005-01-01

    There are several methods to measure soil bulk density (ρ s ) like the paraffin sealed clod (PS), the volumetric ring (VR), the computed tomography (CT), and the neutron-gamma surface gauge (SG). In order to evaluate by a non-destructive way the possible modifications in soil structure caused by sampling for the PS and VR methods of ρ s evaluation we proposed to use the gamma ray CT method. A first generation tomograph was used having a 241 Am source and a 3 in x 3 in NaI(Tl) scintillation crystal detector coupled to a photomultiplier tube. Results confirm the effect of soil sampler devices on the structure of soil samples, and that the compaction caused during sampling causes significant alterations of soil bulk density. Through the use of CT it was possible to determine the level of compaction and to make a detailed analysis of the soil bulk density distribution within the soil sample. (author)

  18. Compliant flooring for fall injury prevention in long-term care

    OpenAIRE

    Lachance, Chantelle

    2017-01-01

    A promising strategy for reducing the incidence and severity of fall-related injuries in long-term care (LTC) is to decrease the ground surface stiffness, and the subsequent forces applied to the body parts at impact, through installation of compliant flooring. Evidence about the feasibility of compliant flooring in LTC is extremely limited. My PhD research addresses this gap by conducting a comprehensive, multimethod evaluation of compliant flooring. Specifically, I investigate the feasibili...

  19. Thermal analysis of a double layer phase change material floor

    International Nuclear Information System (INIS)

    Jin Xing; Zhang Xiaosong

    2011-01-01

    Phase change materials (PCMs) can be used to shift the cooling or heating load from the peak period to the off-peak period. In this paper, a new double layer phase change material (PCM) floor is put forward. The two layers of PCM have different melting temperature. The system is used to store heat or cold energy in the off-peak period and release them in the peak period during heating or cooling. According to the numerical model built in this paper, the thermal performances of the floor are analyzed. The results show that the optimal melting temperatures of PCMs exist. The fluctuations of the floor surface temperatures and the heat fluxes will be reduced and the system still can provide a certain amount of heat or cold energy after the heat pump or chiller has been turned off for a long time. Compared to the floor without PCM, the energy released by the floor with PCM in peak period will be increased by 41.1% and 37.9% during heating and cooling when the heat of fusion of PCM is 150 kJ/kg. - Highlights: → A new double layer phase change material floor is put forward. → The system is used to store heat or cold energy in the off-peak period and release them in the peak period during heating or cooling. → The optimal melting temperatures of PCMs in the system exist. → The heat and cold energy released by the floor with PCM in peak period can be increased by 41.1% and 37.9%.

  20. Cometary water-group ions in the region surrounding Comet Giacobini-Zinner - Distribution functions and bulk parameter estimates

    Science.gov (United States)

    Staines, K.; Balogh, A.; Cowley, S. W. H.; Richardson, I. G.; Sanderson, T. R.; Tsurutani, B. T.

    1991-01-01

    The bulk parameters (number density and thermal energy density) of cometary water-group ions in the region surrounding Comet Giacobini-Zinner have been derived using data from the EPAS instrument on the ICE spacecraft. The derivation is based on the assumption that the pick-up ion distribution function is isotropic in the frame of the bulk flow, an approximation which has previously been shown to be reasonable within about 400,000 km of the comet nucleus along the spacecraft trajectory. The transition between the pick-up and mass-loaded regions occurs at the cometary shock, which was traversed at a cometocentric distance of about 100,000 km along the spacecraft track. Examination of the ion distribution functions in this region, transformed to the bulk flow frame, indicates the occurrence of a flattened distribution in the vicinity of the local pick-up speed, and a steeply falling tail at speeds above, which may be approximated as an exponential in ion speed.

  1. Anisotropic Bianchi Type-III Bulk Viscous Fluid Universe in Lyra Geometry

    Directory of Open Access Journals (Sweden)

    Priyanka Kumari

    2013-01-01

    Full Text Available An anisotropic Bianchi type-III cosmological model is investigated in the presence of a bulk viscous fluid within the framework of Lyra geometry with time-dependent displacement vector. It is shown that the field equations are solvable for any arbitrary function of a scale factor. To get the deterministic model of the universe, we have assumed that (i a simple power-law form of a scale factor and (ii the bulk viscosity coefficient are proportional to the energy density of the matter. The exact solutions of the Einstein’s field equations are obtained which represent an expanding, shearing, and decelerating model of the universe. Some physical and kinematical behaviors of the cosmological model are briefly discussed.

  2. Physico-mechanical characteristics of commercially available bulk-fill composites.

    Science.gov (United States)

    Leprince, Julian G; Palin, William M; Vanacker, Julie; Sabbagh, Joseph; Devaux, Jacques; Leloup, Gaetane

    2014-08-01

    Bulk-fill composites have emerged, arguably, as a new "class" of resin-based composites, which are claimed to enable restoration in thick layers, up to 4mm. The objective of this work was to compare, under optimal curing conditions, the physico-mechanical properties of most currently available bulk-fill composites to those of two conventional composite materials chosen as references, one highly filled and one flowable "nano-hybrid" composite. Tetric EvoCeram Bulk Fill (Ivoclar-Vivadent), Venus Bulk Fill (Heraeus-Kulzer), SDR (Dentsply), X-tra Fil (VOCO), X-tra Base (VOCO), Sonic Fill (Kerr), Filtek Bulk Fill (3M-Espe), Xenius (GC) were compared to the two reference materials. The materials were light-cured for 40s in a 2mm×2mm×25mm Teflon mould. Degree of conversion was measured by Raman spectroscopy, Elastic modulus and flexural strength were evaluated by three point bending, surface hardness using Vickers microindentation before and after 24h ethanol storage, and filler weight content by thermogravimetric analysis. The ratio of surface hardness before and after ethanol storage was considered as an evaluation of polymer softening. Data were analyzed by one-way ANOVA and post hoc Tukey's test (p=0.05). The mechanical properties of the bulk-fill composites were mostly lower compared with the conventional high viscosity material, and, at best, comparable to the conventional flowable composite. Linear correlations of the mechanical properties investigated were poor with degree of conversion (0.090.8). Softening in ethanol revealed differences in polymer network density between material types. The reduction of time and improvement of convenience associated with bulk-fill materials is a clear advantage of this particular material class. However, a compromise with mechanical properties compared with more conventional commercially-available nano-hybrid materials was demonstrated by the present work. Given the lower mechanical properties of most bulk-fill materials

  3. Flux-pinning-induced stress and magnetostriction in bulk superconductors

    International Nuclear Information System (INIS)

    Johansen, Tom H.

    2000-01-01

    The development of bulk high-temperature superconductors (HTSs) and their applications has today come to a point where the mechanical response to high magnetic fields may be more important than their critical-current density and large-grain property. Reviewed in this article are the recent studies of the magneto-elastic effects which are caused by flux pinning in the superconductors. This includes the work on the giant irreversible magnetostriction and internal stress, which often cause fatal cracking of the HTS bulks as they become magnetized. The cracking is a problem that today accompanies the quest for the highest trapped field values, and the latest development in this area is also presented. While the first part is an overview of experimental efforts, the second summarizes the work done to model the pinning-induced stress and strain under various magnetic and geometrical conditions. (author)

  4. Pelvic Floor Physical Therapy for Vulvodynia: A Clinician's Guide.

    Science.gov (United States)

    Prendergast, Stephanie A

    2017-09-01

    Vulvar pain affects up to 20% of women at some point in their lives, and most women with vulvar pain have associated pelvic floor impairments. Pelvic floor dysfunction is associated with significant functional limitations in women by causing painful intercourse and urinary, bowel, and sexual dysfunction. A quick screening of the pelvic floor muscles can be performed in the gynecology office and should be used when patients report symptoms of pelvic pain. It is now known the vulvar pain syndromes are heterogeneous in origin; therefore, successful treatment plans are multimodal and include physical therapy. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Ab-initio Computation of the Electronic, transport, and Bulk Properties of Calcium Oxide.

    Science.gov (United States)

    Mbolle, Augustine; Banjara, Dipendra; Malozovsky, Yuriy; Franklin, Lashounda; Bagayoko, Diola

    We report results from ab-initio, self-consistent, local Density approximation (LDA) calculations of electronic and related properties of calcium oxide (CaO) in the rock salt structure. We employed the Ceperley and Alder LDA potential and the linear combination of atomic orbitals (LCAO) formalism. Our calculations are non-relativistic. We implemented the LCAO formalism following the Bagayoko, Zhao, and Williams (BZW) method, as enhanced by Ekuma and Franklin (BZW-EF). The BZW-EF method involves a methodical search for the optimal basis set that yields the absolute minima of the occupied energies, as required by density functional theory (DFT). Our calculated, indirect band gap of 6.91eV, from towards the L point, is in excellent agreement with experimental value of 6.93-7.7eV, at room temperature (RT). We have also calculated the total (DOS) and partial (pDOS) densities of states as well as the bulk modulus. Our calculated bulk modulus is in excellent agreement with experiment. Work funded in part by the US Department of Energy (DOE), National Nuclear Security Administration (NNSA) (Award No.DE-NA0002630), the National Science Foundation (NSF) (Award No, 1503226), LaSPACE, and LONI-SUBR.

  6. DESIGN AND MANUFACTURING OF MODULAR PARQUET FLOORING IN INDUSTRIAL SYSTEM

    Directory of Open Access Journals (Sweden)

    Ivan CISMARU

    2014-09-01

    Full Text Available The paper submits constructive options and methods to design and manufacture modular parquet flooring, as well as fastening methods in constructions. Likewise, it presents the branches of civil engineering where modular parquet flooring may be turned to profit – industrial buildings, company premises or residential premises. The turn towards the achievement of private constructions, such as individual houses, led to losing control of the modular system applied in defining the inner sizes of the constructions and implicitly to the apparition of dimensional incompatibilities between the parquet flooring and the built spaces. The paper sets out (to solve by an individualized design procedure to achieve modular parquet flooring in industrial system, in correspondence with the sizes of the inner spaces afferent to the constructions.

  7. Physical and chemical test results of electrostatic safe flooring materials

    Science.gov (United States)

    Gompf, R. H.

    1988-01-01

    This test program was initiated because a need existed at the Kennedy Space Center (KSC) to have this information readily available to the engineer who must make the choice of which electrostatic safe floor to use in a specific application. The information, however, should be of value throughout both the government and private industry in the selection of a floor covering material. Included are the test results of 18 floor covering materials which by test evaluation at KSC are considered electrostatically safe. Tests were done and/or the data compiled in the following areas: electrostatics, flammability, hypergolic compatibility, outgassing, floor type, material thickness, and available colors. Each section contains the test method used to gather the data and the test results.

  8. Superconductors, analysis and applications, with special reference to the utilisation of bulk (Re)BCO materials

    Energy Technology Data Exchange (ETDEWEB)

    Coombs, T.A., E-mail: tac1000@cam.ac.u [University of Cambridge, Department of Engineering, Trumpington Street, Cambridge CB2 1PZ (United Kingdom)

    2010-11-01

    The Electrical Power and Energy Conversion (EPEC) superconductivity group at Cambridge University has been working on the application of superconductivity to large scale devices. This work is taking place over a range of areas which cover FCLs, motors and generators, SMES, accelerator magnets and MRI. The research is underpinned by advanced modelling techniques using both pure Critical State models and E-J models to analyse the behaviour of the superconductors. As part of the device design we are concentrating on the analysis of AC losses in complicated geometries such as are found in motor windings and the magnetisation of bulk superconductors to enable their full potential to be realised. We are interested in the full range of high-temperature superconductors and have measured and predicted the performance of YBCO, MgB{sub 2} and BSCCO at a range of temperatures and in wire, tape and bulk forms. This paper concentrates on recent work which includes: modelling of coils using formulations based on H and A. A critical state model for the analysis of coils in SMES; crossed field effects in bulk superconductors; a magnetic model together with experimental results which explain and describe the method of flux pumping whereby a bulk superconductor can be magnetised to a high flux density using a repeatedly applied field of low flux density and finally a new configuration for MRI magnets

  9. CAISSON TYPE HOLLOW FLOOR SLABS OF MONOLITHIC MULTI-STOREYED BUILDINGS

    OpenAIRE

    Malakhova Anna Nikolaevna

    2016-01-01

    One of the disadvantages of building structures made of reinforced concrete is their considerable weight. One of the trends to decrease the weight of concrete structures, including floor slabs, is the arrangement of voids in the cross-sectional building structures. In Russian and foreign practice paper, cardboard and plastic tubes has been used for creation of voids in the construction of monolithic floor slabs. Lightweight concretes were also used for production of precast hollow core floor ...

  10. Perovskite oxides: Oxygen electrocatalysis and bulk structure

    Science.gov (United States)

    Carbonio, R. E.; Fierro, C.; Tryk, D.; Scherson, D.; Yeager, Ernest

    1987-01-01

    Perovskite type oxides were considered for use as oxygen reduction and generation electrocatalysts in alkaline electrolytes. Perovskite stability and electrocatalytic activity are studied along with possible relationships of the latter with the bulk solid state properties. A series of compounds of the type LaFe(x)Ni1(-x)O3 was used as a model system to gain information on the possible relationships between surface catalytic activity and bulk structure. Hydrogen peroxide decomposition rate constants were measured for these compounds. Ex situ Mossbauer effect spectroscopy (MES), and magnetic susceptibility measurements were used to study the solid state properties. X ray photoelectron spectroscopy (XPS) was used to examine the surface. MES has indicated the presence of a paramagnetic to magnetically ordered phase transition for values of x between 0.4 and 0.5. A correlation was found between the values of the MES isomer shift and the catalytic activity for peroxide decomposition. Thus, the catalytic activity can be correlated to the d-electron density for the transition metal cations.

  11. The measurement of moisture content and dry bulk-density of the top layer of agricultural soils, with minimum calibration, using a gamma-ray attenuation method

    International Nuclear Information System (INIS)

    Van der Westhuizen, M.; Van der Bank, D.J.; Meulke, M.

    1978-06-01

    Various methods of measuring moisture content and dry bulk-density of soil by means of gamma-ray attenuation are discussed. A new method is described in which the same parameters can be measured in consecutive determinations, but for which only one sample of unknown volume is needed for calibration. This method employs a radioactive source in a lead container in an aluminium tube in the soil. From the container the gamma rays follow a path at an angle upwards through the soil towards the detector. The method was tested in a number of experiments and the results are given in tables and graphs. The conclusion is that this method, which is fairly easy and quick to use, is accurate enough for most applications [af

  12. Contact resistance problems applying ERT on low bulk density forested stony soils. Is there a solution?

    Science.gov (United States)

    Deraedt, Deborah; Touzé, Camille; Robert, Tanguy; Colinet, Gilles; Degré, Aurore; Garré, Sarah

    2015-04-01

    contact resistance reduced to 5222 Ω. This improved the contact resistance substantially, but complicates the execution of a pulse tracer experiment. To date we did not find any better solution to this problem and we keep searching a way to improve the contact resistance in stony forested soils with very low bulk density. We would like to exchange on these questions with EGU attendees in order to improve the experimental design or point out a new research path for these specific conditions. This could lead to enhance the use of ERT in soils with low density and high stone content.

  13. Error Floor Analysis of Coded Slotted ALOHA over Packet Erasure Channels

    DEFF Research Database (Denmark)

    Ivanov, Mikhail; Graell i Amat, Alexandre; Brannstrom, F.

    2014-01-01

    We present a framework for the analysis of the error floor of coded slotted ALOHA (CSA) for finite frame lengths over the packet erasure channel. The error floor is caused by stopping sets in the corresponding bipartite graph, whose enumeration is, in general, not a trivial problem. We therefore ...... identify the most dominant stopping sets for the distributions of practical interest. The derived analytical expressions allow us to accurately predict the error floor at low to moderate channel loads and characterize the unequal error protection inherent in CSA.......We present a framework for the analysis of the error floor of coded slotted ALOHA (CSA) for finite frame lengths over the packet erasure channel. The error floor is caused by stopping sets in the corresponding bipartite graph, whose enumeration is, in general, not a trivial problem. We therefore...

  14. Touch Is Everywhere: Floor Surfaces as Ambient Haptic Interfaces.

    Science.gov (United States)

    Visell, Y; Law, A; Cooperstock, J R

    2009-01-01

    Floor surfaces are notable for the diverse roles that they play in our negotiation of everyday environments. Haptic communication via floor surfaces could enhance or enable many computer-supported activities that involve movement on foot. In this paper, we discuss potential applications of such interfaces in everyday environments and present a haptically augmented floor component through which several interaction methods are being evaluated. We describe two approaches to the design of structured vibrotactile signals for this device. The first is centered on a musical phrase metaphor, as employed in prior work on tactile display. The second is based upon the synthesis of rhythmic patterns of virtual physical impact transients. We report on an experiment in which participants were able to identify communication units that were constructed from these signals and displayed via a floor interface at well above chance levels. The results support the feasibility of tactile information display via such interfaces and provide further indications as to how to effectively design vibrotactile signals for them.

  15. Floor cleaning: effect on bacteria and organic materials in hospital rooms.

    Science.gov (United States)

    Andersen, B M; Rasch, M; Kvist, J; Tollefsen, T; Lukkassen, R; Sandvik, L; Welo, A

    2009-01-01

    Routine surface cleaning is recommended to control the spread of pathogens in hospital environments. In Norway, ordinary cleaning of patient rooms is traditionally performed with soap and water. In this study, four floor-mopping methods--dry, spray, moist and wet mopping--were compared by two systems using adenosine triphosphate (ATP) bioluminescence (Hygiena and Biotrace). These systems assess residual organic soil on surfaces. The floor-mopping methods were also assessed by microbiological samples from the floor and air, before and after cleaning. All methods reduced organic material on the floors but wet and moist mopping seemed to be the most effective (P < 0.001, P < 0.011, respectively, ATP Hygiena). The two ATP methods were easy to use, although each had their own reading scales. Cleaning reduced organic material to 5-36% of the level present before cleaning, depending upon mopping method. All four mopping methods reduced bacteria on the floor from about 60-100 to 30-60 colony-forming units (cfu)/20cm2 floor. Wet, moist and dry mopping seemed to be more effective in reducing bacteria on the floor, than the spray mopping (P=0.007, P=0.002 and P=0.011, respectively). The burden of bacteria in air increased for all methods just after mopping. The overall best cleaning methods seemed to be moist and wet mopping.

  16. Linking chemical elements in forest floor humus (Oh-horizon) in the Czech Republic to contamination sources

    International Nuclear Information System (INIS)

    Sucharova, Julie; Suchara, Ivan; Hola, Marie; Reimann, Clemens; Boyd, Rognvald; Filzmoser, Peter; Englmaier, Peter

    2011-01-01

    While terrestrial moss and other plants are frequently used for environmental mapping and monitoring projects, data on the regional geochemistry of humus are scarce. Humus, however, has a much larger life span than any plant material. It can be seen as the 'environmental memory' of an area for at least the last 60-100 years. Here concentrations of 39 elements determined by ICP-MS and ICP AES, pH and ash content are presented for 259 samples of forest floor humus collected at an average sample density of 1 site/300 km 2 in the Czech Republic. The scale of anomalies linked to known contamination sources (e.g., lignite mining and burning, metallurgical industry, coal fired power plants, metal smelters) is documented and discussed versus natural processes influencing humus quality. Most maps indicate a local impact from individual contamination sources: often more detailed sampling than used here would be needed to differentiate between likely sources. - Highlights: → Concentrations of 39 elements in forest floor humus are provided. → The capabilities of humus sampling for bio-monitoring purposes are demonstrated. → Geochemical anomalies are linked to known contamination sources. → The study shows the importance of scale for geochemical mapping projects. → Humus provides a picture of the long term contamination history of a country. - Forest floor humus, the atmosphere-biosphere-pedosphere interface, archives an environmental contamination signal over long time periods.

  17. Bridge density functional approximation for non-uniform hard core repulsive Yukawa fluid

    International Nuclear Information System (INIS)

    Zhou Shiqi

    2008-01-01

    In this work, a bridge density functional approximation (BDFA) (J. Chem. Phys. 112, 8079 (2000)) for a non-uniform hard-sphere fluid is extended to a non-uniform hard-core repulsive Yukawa (HCRY) fluid. It is found that the choice of a bulk bridge functional approximation is crucial for both a uniform HCRY fluid and a non-uniform HCRY fluid. A new bridge functional approximation is proposed, which can accurately predict the radial distribution function of the bulk HCRY fluid. With the new bridge functional approximation and its associated bulk second order direct correlation function as input, the BDFA can be used to well calculate the density profile of the HCRY fluid subjected to the influence of varying external fields, and the theoretical predictions are in good agreement with the corresponding simulation data. The calculated results indicate that the present BDFA captures quantitatively the phenomena such as the coexistence of solid-like high density phase and low density gas phase, and the adsorption properties of the HCRY fluid, which qualitatively differ from those of the fluids combining both hard-core repulsion and an attractive tail. (condensed matter: structure, thermal and mechanical properties)

  18. Robust Floor Determination Algorithm for Indoor Wireless Localization Systems under Reference Node Failure

    Directory of Open Access Journals (Sweden)

    Kriangkrai Maneerat

    2016-01-01

    Full Text Available One of the challenging problems for indoor wireless multifloor positioning systems is the presence of reference node (RN failures, which cause the values of received signal strength (RSS to be missed during the online positioning phase of the location fingerprinting technique. This leads to performance degradation in terms of floor accuracy, which in turn affects other localization procedures. This paper presents a robust floor determination algorithm called Robust Mean of Sum-RSS (RMoS, which can accurately determine the floor on which mobile objects are located and can work under either the fault-free scenario or the RN-failure scenarios. The proposed fault tolerance floor algorithm is based on the mean of the summation of the strongest RSSs obtained from the IEEE 802.15.4 Wireless Sensor Networks (WSNs during the online phase. The performance of the proposed algorithm is compared with those of different floor determination algorithms in literature. The experimental results show that the proposed robust floor determination algorithm outperformed the other floor algorithms and can achieve the highest percentage of floor determination accuracy in all scenarios tested. Specifically, the proposed algorithm can achieve greater than 95% correct floor determination under the scenario in which 40% of RNs failed.

  19. Density and mechanical properties of calcium aluminate cement

    Science.gov (United States)

    Ahmed, Syed Taqi Uddin; Ahmmad, Shaik Kareem

    2018-04-01

    Calcium aluminate cements are a special type of cements which have their composition mainly dominated by the presence of Monocalcium Aluminates. In the present paper for the first time we have shown theoretical density and elastic constants for various calcium aluminate cements. The density of the present CAS decrease with aluminates presents in the cement. Using the density data, the elastic moduli namely Young's modulus, bulk and shear modulus show strong linear dependence as a function of compositional parameter.

  20. Sea-floor geology in northwestern Block Island Sound, Rhode Island

    Science.gov (United States)

    McMullen, Katherine Y.; Poppe, Lawrence J.; Ackerman, Seth D.; Blackwood, Dann S.; Woods, D.A.

    2014-01-01

    Multibeam-echosounder and sidescan-sonar data, collected by the National Oceanic and Atmospheric Administration in a 69-square-kilometer area of northwestern Block Island Sound, are used with sediment samples, and still and video photography of the sea floor, collected by the U.S. Geological Survey at 43 stations within this area, to interpret the sea-floor features and sedimentary environments. Features on the sea floor include boulders, sand waves, scour depressions, modern marine sediments, and trawl marks. Boulders, which are often several meters wide, are found in patches in the shallower depths and tend to be overgrown with sessile flora and fauna. They are lag deposits of winnowed glacial drift, and reflect high-energy environments characterized by processes associated with erosion and nondeposition. Sand waves and megaripples tend to have crests that either trend parallel to shore with 20- to 50-meter (m) wavelengths or trend perpendicular to shore with several-hundred-meter wavelengths. The sand waves reflect sediment transport directions perpendicular to shore by waves, and parallel to shore by tidal or wind-driven currents, respectively. Scour depressions, which are about 0.5 m lower than the surrounding sea floor, have floors of gravel and coarser sand than bounding modern marine sediments. These scour depressions, which are conspicuous in the sidescan-sonar data because of their more highly reflective coarser sediment floors, are likely formed by storm-generated, seaward-flowing currents and maintained by the turbulence in bottom currents caused by their coarse sediments. Areas of the sea floor with modern marine sediments tend to be relatively flat to current-rippled and sandy.

  1. 17 CFR 155.2 - Trading standards for floor brokers.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 1 2010-04-01 2010-04-01 false Trading standards for floor brokers. 155.2 Section 155.2 Commodity and Securities Exchanges COMMODITY FUTURES TRADING COMMISSION TRADING STANDARDS § 155.2 Trading standards for floor brokers. Each contract market shall adopt and submit...

  2. Characterization of the protective capacity of flooring systems using force-deflection profiling.

    Science.gov (United States)

    Glinka, Michal N; Karakolis, Thomas; Callaghan, Jack P; Laing, Andrew C

    2013-01-01

    'Safety floors' aim to decrease the risk of fall-related injuries by absorbing impact energy during falls. Ironically, excessive floor deflection during walking or standing may increase fall risk. In this study we used a materials testing system to characterize the ability of a range of floors to absorb energy during simulated head and hip impacts while resisting deflection during simulated single-leg stance. We found that energy absorption for all safety floors (mean (SD)=14.8 (4.9)J) and bedside mats (25.1 (9.3)J) was 3.2- to 5.4-fold greater than the control condition (commercial carpet). While footfall deflections were not significantly different between safety floors (1.8 (0.7)mm) and the control carpet (3.7 (0.6)mm), they were significantly higher for two bedside mats. Finally, all of the safety floors, and two bedside mats, displayed 3-10 times the energy-absorption-to-deflection ratios observed for the baseline carpet. Overall, these results suggest that the safety floors we tested effectively addressed two competing demands required to reduce fall-related injury risk; namely the ability to absorb substantial impact energy without increasing footfall deflections. This study contributes to the literature suggesting that safety floors are a promising intervention for reducing fall-related injury risk in older adults. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  3. Floor response spectra of buildings with uncertain structural properties

    International Nuclear Information System (INIS)

    Chen, P.C.

    1975-01-01

    All Category I equipment, such as reactors, vessels, and major piping systems of nuclear power plants, is required to withstand earthquake loadings in order to minimize risk of seismic damage. The equipment is designed by using response spectra of the floor on which the equipment is mounted. The floor response spectra are constructed usually from the floor response time histories which are obtained through a deterministic dynamic analysis. This analysis assumes that all structural parameters, such as mass, stiffness, and damping have been calculated precisely, and that the earthquakes are known. However, structural parameters are usually difficult to determine precisely if the structures are massive and/or irregular, such as nuclear containments and its internal structures with foundation soil incorporated into the analysis. Faced with these uncertainties, it has been the practice to broaden the floor response spectra peaks by +-10 percent of the peak frequencies on the basis of conservatism. This approach is based on engineering judgement and does not have an analytical basis to provide a sufficient level of confidence in using these spectra for equipment design. To insure reliable design, it is necessary to know structural response variations due to variations in structural properties. This consideration leads to the treatment of structural properties as random variables and the use of probabilistic methods to predict structural response more accurately. New results on floor response spectra of buildings with uncertain structural properties obtained by determining the probabilistic dynamic response from the deterministic dynamic response and its standard deviation are presented. The resulting probabilistic floor response spectra are compared with those obtained deterministically, and are shown to provide a more reliable method for determining seismic forces

  4. Development of a 3-dimensional seismic isolation floor for computer systems

    International Nuclear Information System (INIS)

    Kurihara, M.; Shigeta, M.; Nino, T.; Matsuki, T.

    1991-01-01

    In this paper, we investigated the applicability of a seismic isolation floor as a method for protecting computer systems from strong earthquakes, such as computer systems in nuclear power plants. Assuming that the computer system is guaranteed for 250 cm/s 2 of input acceleration in the horizontal and vertical directions as the seismic performance, the basic design specification of the seismic isolation floor is considered as follows. Against S 1 level earthquakes, the maximum acceleration response of the seismic isolation floor in the horizontal and vertical directions is kept less than 250 cm/s 2 to maintain continuous computer operation. Against S 2 level earthquakes, the isolation floor allows large horizontal movement and large displacement of the isolation devices to reduce the acceleration response, although it is not guaranteed to be less than 250 cm/s 2 . By reducing the acceleration response, however, serious damage to the computer systems is reduced, so that they can be restarted after an earthquake. Usually, seismic isolation floor systems permit 2-dimensional (horizontal) isolation. However, in the case of just-under-seated earthquakes, which have large vertical components, the vertical acceleration response of this system is amplified by the lateral vibration of the frame of the isolation floor. Therefore, in this study a 3-dimensional seismic isolation floor, including vertical isolation, was developed. This paper describes 1) the experimental results of the response characteristics of the 3-dimensional seismic isolation floor built as a trial using a 3-dimensional shaking table, and 2) comparison of a 2-dimensional analytical model, for motion in one horizontal direction and the vertical direction, to experimental results. (J.P.N.)

  5. Sea-floor morphology and sedimentary environments in southern Narragansett Bay, Rhode Island

    Science.gov (United States)

    McMullen, Katherine Y.; Poppe, Lawrence J.; Blackwood, Dann S.; Nardi, Matthew J.; Andring, Matthew A.

    2015-09-09

    Multibeam echosounder data collected by the National Oceanic and Atmospheric Administration along with sediment samples and still and video photography of the sea floor collected by the U.S. Geological Survey were used to interpret sea-floor features and sedimentary environments in southern Narragansett Bay, Rhode Island, as part of a long-term effort to map the sea floor along the northeastern coast of the United States. Sea-floor features include rocky areas and scour depressions in high-energy environments characterized by erosion or nondeposition, and sand waves and megaripples in environments characterized by coarse-grained bedload transport. Two shipwrecks are also located in the study area. Much of the sea floor is relatively featureless within the resolution of the multibeam data; sedimentary environments in these areas are characterized by processes associated with sorting and reworking. This report releases bathymetric data from the multibeam echosounder, grain-size analyses of sediment samples, and photographs of the sea floor and interpretations of the sea-floor features and sedimentary environments. It provides base maps that can be used for resource management and studies of topics such as benthic ecology, contaminant inventories, and sediment transport.

  6. Floor heating and cooling combined with displacement ventilation: Possibilities and limitations

    Energy Technology Data Exchange (ETDEWEB)

    Causone, Francesco; Corgnati, Stefano P. [TEBE Research Group, Department of Energetics, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Torino (Italy); Baldin, Fabio [Department of Applied Physics, University of Padova, via Venezia 1, 35131 Padova (Italy); Olesen, Bjarne W. [ICIEE, Department of Civil Engineering, Technical University of Denmark, Nils Koppels Alle Building 402, 2800 Kgs. Lyngby (Denmark)

    2010-12-15

    Design guidelines envisage that floor heating can be used together with displacement ventilation (DV), provided that the supply air is not overly heated before it can reach heat and contaminant sources. If this is not controlled a mixing flow pattern could occur in the room. The use of floor cooling with DV is also considered possible, although draught risk at ankle level and vertical air temperature differences must be controlled carefully, because they could increase. Few studies on these topics were found in the literature. An indoor environmental chamber was set up to obtain measurements aimed at analysing the possibilities and limitations of combining floor heating/cooling with DV. Air temperature profiles, air velocity profiles, surface temperatures and ventilation effectiveness were measured under different environmental conditions that may occur in practice. These values were compared to equivalent temperature measurements obtained using a thermal manikin. The measurements show that floor heating can be used with DV, obtaining high ventilation effectiveness values. A correlation between the floor heating capacity and the air temperature profile in the room was found. Measurements showed that floor cooling does not increase draught risk at ankle level, although it does increase vertical air temperature differences. (author)

  7. Pyroclastic Deposits in the Floor-fractured Crater Alphonsus

    Science.gov (United States)

    Allen, Carlton C.; Donaldson-Hanna, Kerri L.; Pieters, Carle M.; Moriarty, Daniel P.; Greenhagen, Benjamin T.; Bennett, Kristen A.; Kramer, Georgiana Y.; Paige, David A.

    2013-01-01

    Alphonsus, the 118 km diameter floor-fractured crater, is located immediately east of Mare Nubium. Eleven pyroclastic deposits have been identified on the crater's floor. Early telescopic spectra suggest that the floor of Alphonsus is noritic, and that the pyroclastic deposits contain mixtures of floor material and a juvenile component including basaltic glass. Head and Wilson contend that Nubium lavas intruded the breccia zone beneath Alphonsus, forming dikes and fractures on the crater floor. In this model, the magma ascended to the level of the mare but cooled underground, and a portion broke thru to the surface in vulcanian (explosive) eruptions. Alternatively, the erupted material could be from a source unrelated to the mare, in the style of regional pyroclastic deposits. High-resolution images and spectroscopy from the Moon Mineralogy Mapper (M3), Diviner Lunar Radiometer, and Lunar Reconnaissance Orbiter Camera Narrow Angle Camera (NAC) provide data to test these formation models. Spectra from M3 confirm that the crater floor is primarily composed of noritic material, and that the Nubium lavas are basaltic. Spectra from the three largest pyroclastic deposits in Alphonsus are consistent with a minor low- Ca pyroxene component in a glass-rich matrix. The centers of the 2 micron absorption bands have wavelengths too short to be of the same origin as the Nubium basalts. Diviner Christiansen feature (CF) values were used to estimate FeO abundances for the crater floor, Nubium soil, and pyroclastic deposits. The estimated abundance for the crater floor (7.5 +/- 1.4 wt.%) is within the range of FeO values for Apollo norite samples. However, the estimated FeO abundance for Nubium soil (13.4 +/- 1.4 wt.%) is lower than those measured in most mare samples. The difference may reflect contamination of the mare soil by highland ejecta. The Diviner-derived FeO abundance for the western pyroclastic deposit is 13.8 +/- 3.3 wt.%. This is lower than the values for mare soil

  8. Investigation of the thermal resistance of timber attic spaces with reflective foil and bulk insulation, heat flow up

    Energy Technology Data Exchange (ETDEWEB)

    Belusko, M.; Bruno, F.; Saman, W. [Institute for Sustainable Systems and Technologies, University of South Australia, Mawson Lakes Boulevard, SA 5095 (Australia)

    2011-01-15

    An experimental investigation was undertaken in which the thermal resistance for the heat flow through a typical timber framed pitched roofing system was measured under outdoor conditions for heat flow up. The measured thermal resistance of low resistance systems such as an uninsulated attic space and a reflective attic space compared well with published data. However, with higher thermal resistance systems containing bulk insulation within the timber frame, the measured result for a typical installation was as low as 50% of the thermal resistance determined considering two dimensional thermal bridging using the parallel path method. This result was attributed to three dimensional heat flow and insulation installation defects, resulting from the design and construction method used. Translating these results to a typical house with a 200 m{sup 2} floor area, the overall thermal resistance of the roof was at least 23% lower than the overall calculated thermal resistance including two dimensional thermal bridging. When a continuous layer of bulk insulation was applied to the roofing system, the measured values were in agreement with calculated resistances representing a more reliable solution. (author)

  9. Effect of different flooring systems on claw conformation of dairy cows.

    Science.gov (United States)

    Telezhenko, E; Bergsten, C; Magnusson, M; Nilsson, C

    2009-06-01

    The effect of different flooring surfaces in walking and standing areas on claw conformation, claw horn growth, and wear was studied in 2 experiments during 2 consecutive housing seasons in a research dairy herd of 170 cows. In experiment 1, the flooring systems tested were solid rubber mats, mastic asphalt with and without rubber-matted feed-stalls, and aged concrete slats. In experiment 2, slatted concrete flooring was compared with slatted rubber flooring. The cows were introduced to the respective flooring systems in early lactation and their claws were trimmed before the exposure period. Toe length, toe angle, sole concavity, and claw width, as well as claw growth and wear rates were recorded for lateral and medial claws of the left hind limb. Claw asymmetry calculations were based on these claw measurements and on differences in sole protrusion between lateral and medial soles. Asphalt floors caused shorter toe length and steeper toe angle. They also increased wear on rear claws (5.30 +/- 0.31 and 5.95 +/- 0.33 mm/mo for lateral and medial claw, respectively; LSM +/- SE) and horn growth rate (5.12 +/- 0.36 and 5.83 +/- 0.31 mm/mo of lateral and medial claws, respectively). Rubber mats instead of asphalt in walking areas reduced wear (1.36 +/- 0.19 and 2.02 +/- 0.20 mm/mo for lateral and medial claw, respectively) and claw growth (3.83 +/- 0.23 and 3.94 +/- 0.17 mm/mo for lateral and medial claw, respectively). Rubber-matted feed-stalls together with asphalt walkways decreased claw wear (3.29 +/- 0.31 and 4.10 +/- 0.32 mm/mo for lateral and medial claw, respectively). The concavity of claw soles was reduced on asphalt, especially in the lateral rear claws. Rubber matting in feed-stalls prevented loss of sole concavity compared with asphalt. Claw asymmetry did not differ between flooring systems. While different access to abrasive flooring affected claw conformation, there was no evidence that flooring system influenced the disproportion between lateral and

  10. Fabrication of Bi2223 bulks with high critical current properties sintered in Ag tubes

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, Yasuaki, E-mail: ytakeda@g.ecc.u-tokyo.ac.jp [Department of Applied Chemistry, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Shimoyama, Jun-ichi; Motoki, Takanori [Department of Physics and Mathematics, Aoyama Gakuin University, 5-10-1 Fuchinobe, Chuo-ku, Sagamihara, Kanagawa 252-5258 (Japan); Kishio, Kohji [Department of Applied Chemistry, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Nakashima, Takayoshi; Kagiyama, Tomohiro; Kobayashi, Shin-ichi; Hayashi, Kazuhiko [Sumitomo Electric Industries, Ltd. 1-1-3 Shimaya, Konohana-ku, Osaka 554-0024 (Japan)

    2017-03-15

    Highlights: • Fabrication conditions of Bi2223 bulks was reconsidered in terms of high J{sub c}. • Pressure of uniaxial pressing and heat treatment conditions were investigated. • The best sample showed higher J{sub c} than that of practically used Bi2223 bulks. - Abstract: Randomly grain oriented Bi2223 sintered bulks are one of the representative superconducting materials having weak-link problem due to very short coherence length particularly along the c-axis, resulting in poor intergrain J{sub c} properties. In our previous studies, sintering and/or post-annealing under moderately reducing atmospheres were found to be effective for improving grain coupling in Bi2223 sintered bulks. Further optimizations of the synthesis process for Bi2223 sintered bulks were attempted in the present study to enhance their intergrain J{sub c}. Effects of applied pressure of uniaxial pressing and sintering conditions on microstructure and superconducting properties have been systematically investigated. The best sample showed intergrain J{sub c} of 2.0 kA cm{sup −2} at 77 K and 8.2 kA cm{sup −2} at 20 K, while its relative density was low ∼65%. These values are quite high as for a randomly oriented sintered bulk of cuprate superconductors.

  11. THE COSMOLOGICAL BULK FLOW: CONSISTENCY WITH ΛCDM AND z ∼ 0 CONSTRAINTS ON σ8 AND γ

    International Nuclear Information System (INIS)

    Nusser, Adi; Davis, Marc

    2011-01-01

    We derive estimates for the cosmological bulk flow from the SFI++ Tully-Fisher (TF) catalog. For a sphere of radius 40 h -1 Mpc centered on the Milky Way, we derive a bulk flow of 333 ± 38 km s -1 toward Galactic (l, b) = (276 deg., 14 deg.) within a 3 0 1σ error. Within a radius of 100h -1 Mpc we get 257 ± 44 km s -1 toward (l, b) = (279 deg., 10 deg.) within a 6 deg. error. These directions are at 40 deg. to the Supergalactic plane, close to the apex of the motion of the Local Group of galaxies after the Virgocentric infall correction. Our findings are consistent with the ΛCDM model with the latest Wilkinson Microwave Anisotropy Probe (WMAP) best-fit cosmological parameters, but the bulk flow allows independent constraints. For the WMAP-inferred Hubble parameter h = 0.71 and baryonic mean density parameter Ω b = 0.0449, the constraint from the bulk flow on the matter density, Ω m , the normalization of the density fluctuations, σ 8 , and the growth index, γ, can be expressed as σ 8 Ω γ-0.55 m (Ω m /0.266) 0.28 = 0.86 ± 0.11 (for Ω m ∼ 0.266). Fixing σ 8 = 0.8 and Ω m = 0.266 as favored by WMAP, we get γ = 0.495 ± 0.096. The constraint derived here rules out popular Dvali-Gabadadze-Porrati models at more than the 99% confidence level. Our results are based on the All Space Constrained Estimate (ACSE) model which reconstructs the bulk flow from an all space three-dimensional peculiar velocity field constrained to match the TF measurements. At large distances, ASCE generates a robust bulk flow from the SFI++ survey that is insensitive to the assumed prior. For comparison, a standard straightforward maximum likelihood estimate leads to very similar results.

  12. Regular exercisers have stronger pelvic floor muscles than nonregular exercisers at midpregnancy.

    Science.gov (United States)

    Bø, Kari; Ellstrøm Engh, Marie; Hilde, Gunvor

    2018-04-01

    Today all healthy pregnant women are encouraged to be physically active throughout pregnancy, with recommendations to participate in at least 30 minutes of aerobic activity on most days of the week in addition to performing strength training of the major muscle groups 2-3 days per week and also pelvic floor muscle training. There is, however, an ongoing debate whether general physical activity enhances or declines pelvic floor muscle function. The objectives of the study were to compare vaginal resting pressure, pelvic floor muscle strength, and endurance in regular exercisers (exercise ≥30 minutes 3 or more times per week) and nonexercisers at midpregnancy. Furthermore, another objective was to assess whether regular general exercise or pelvic floor muscle strength was associated with urinary incontinence. This was a cross-sectional study at mean gestational week 20.9 (±1.4) including 218 nulliparous pregnant women, with a mean age of 28.6 years (range, 19-40 years) and prepregnancy body mass index of 23.9 kg/m 2 (SD, 4.0). Vaginal resting pressure, pelvic floor muscle strength, and pelvic floor muscle endurance were measured by a high-precision pressure transducer connected to a vaginal balloon. The International Consultation on Incontinence Questionnaire Urinary Incontinence Short Form was used to assess urinary incontinence. Differences between groups were analyzed using an independent-sample Student t test. Linear regression analysis was conducted to adjust for prepregnancy body mass index, age, smoking during pregnancy, and regular pelvic floor muscle training during pregnancy. The significance value was set to P ≤ .05. Regular exercisers had statistically significant stronger (mean 6.4 cm H 2 O [95% confidence interval, 1.7-11.2]) and more enduring (mean 39.9 cm H 2 Osec [95% confidence interval, 42.2-75.7]) pelvic floor muscles. Only pelvic floor muscle strength remained statistically significant, when adjusting for possible confounders. Pelvic floor

  13. Bulk Soil Organic Matter d2H as a Precipitation Proxy

    Science.gov (United States)

    Williams, E. K.; Terwilliger, V. J.; Nakamoto, B. J.; Berhe, A. A.; Fogel, M. L.

    2016-12-01

    The stable hydrogen isotopic composition (d2H) of leaf waxes have traditionally been used to infer modern and paleoclimate precipitation sources. However, the extent to which evapotranspiration of leaf waters affects the d2H of plant leaf waxes remains hotly contested with offsets varying between species. Because of the relative importance of root organic matter contribution to bulk soil pools compared to litter/leaves and the minimal fractionation between soil water and root material, it is plausible that bulk soil organic matter d2H may be an option for modern and paleoclimate precipitation reconstructions. In this study, we analyzed the non-exchangeable d2H composition of roots, litter, leaves, and bulk soils along an elevation gradient in the southern Sierra Nevada range (USA). Our results show a consistent offset of 30 ± 3‰ in bulk soil organic matter in surface soils from the measured precipitation. This consistent relationship with precipitation was not found in any of the other organic materials that we measured and implies that d2H bulk soil organic matter can record precipitation signals regardless of above-ground species composition. Additionally, we utilized physical density fractionation to determine which fractions (which vary in level of mineral association and in turnover time) of the soil control this relationship. These findings and how this relationship holds with depth will be presented in conjunction with data from a soil profile on the Ethiopian plateau spanning 6000 years.

  14. Influence of the size of Gd211 starting powder on the critical current density of Gd-Ba-Cu-O bulk superconductor

    International Nuclear Information System (INIS)

    Nariki, S.; Seo, S.J.; Sakai, N.; Murakami, M.

    2000-01-01

    The relationship between the particle size of Gd211 powder in the precursor and the particle size of Gd211 inclusions in Gd-Ba-Cu-O bulk has been investigated. Gd211 starting powders with various diameters were prepared by the calcination of Gd 2 O 3 , BaO 2 and CuO powders at different temperatures between 800 and 1000 deg. C. The particle size of Gd211 in the melt-grown bulk was proportional to the particle size of the initial Gd211 powder. In conclusion, the employment of fine Gd211 powder led to a size reduction of 211 particles in the bulk, while largely enhancing the J c values in low magnetic fields. A large Gd-Ba-Cu-O/Ag bulk sample, 32 mm in diameter, could also be fabricated by the hot-seeding method. The maximum trapped field value revealed 1.5 T at 77 K. (author)

  15. Energy and Pitch Distribution of Spontaneously-generated High-energy Bulk Ions in the RFP

    Science.gov (United States)

    Kim, Jungha; Anderson, Jay; Reusch, Joshua; Eilerman, Scott; Capecchi, William

    2014-10-01

    Magnetic reconnection events in the reversed field pinch (RFP) are known to heat bulk and impurity ions. Runaway due to a parallel electric field has recently been confirmed as an important acceleration mechanism for high energy test ions supplied by a neutral beam. This effect does not, however, explain the change in distribution of nearly Maxwellian bulk ions at a reconnection event. By operating MST near maximum current and low electron density, significant fusion neutron flux can be generated without neutral beam injection. The bulk ion distribution created in these plasmas is well-confined, non-Maxwellian, and can be measured by the Advanced Neutral Particle Analyzer (ANPA) placed at a radial or tangential porthole. Data show a high energy tail up to 25 keV with a relatively higher signal in the low energy channels (8-15 keV) at the radial port following a reconnection event. Analysis of the energy dependence of trapped orbits sampled by the ANPA at the radial view implies an abundance of lower energy particles in regions of higher neutral density. This mandates a careful deconvolution of the measured ANPA signal to compute the fast ion distribution. This work is supported by the US DOE and NSF.

  16. Generation of airborne Listeria innocua from model floor drains.

    Science.gov (United States)

    Berrang, Mark E; Frank, Joseph F

    2012-07-01

    Listeria monocytogenes can colonize floor drains in poultry processing and further processing facilities, remaining present even after cleaning and disinfection. Therefore, during wash down, workers exercise caution to avoid spraying hoses directly into drains in an effort to prevent the escape and transfer of drain microflora to food contact surfaces. The objective of this study was to examine the extent to which an inadvertent water spray into a colonized floor drain can cause the spread of airborne Listeria. Listeria innocua was used to inoculate a polyvinyl chloride model floor drain, resulting in approximately 10(8) cells per ml of phosphate-buffered saline and 10(4) attached cells per square centimeter of inner surface. Each model drain was subjected to a 2-s spray of tap water at 68.9 kPa from a distance of 1 m. Drains were sprayed while filled and again after emptying. Airborne cells were collected by using sedimentation plates containing Listeria selective agar which were placed on the floor and walls of a contained room at incremental horizontal and vertical distances of 0.6, 1.2, 2.4, or 4.0 m from the drain. Sedimentation plates were exposed for 10 min. A mechanical sampler was used to also collect air by impaction on the surface of Listeria selective agar to determine the number of cells per liter of air. The experiment was conducted in triplicate rooms for each of four replications. L. innocua was detected on sedimentation plates on the floor as far as 4.0 m from the drain and on walls as high as 2.4 m above the floor and 4 m from the drain. A 2-s spray with a water hose into a contaminated drain can cause airborne spread of Listeria, resulting in the potential for cross-contamination of food contact surfaces, equipment, and exposed product.

  17. Clinical functional evaluation of female's pelvic floor: integrative review

    Directory of Open Access Journals (Sweden)

    Ana Carolina Nociti Lopes Fernandes

    2018-06-01

    Full Text Available Abstract Introduction: The effectiveness of pelvic floor muscle training (PFMT depends on the correct prescription of intensity, repetition and endurance of muscle contractions, which are provided by an adequate assessment of pelvic floor muscle. Objective: Verify the techniques, resources and strategies used for clinical functional evaluation of female pelvic floor (PF described in literature. Methods: It’s an integrative review of published studies and books from 2010 until December 2015. Relevant articles with complete description of PF evaluation were found through the use of Scielo, LILACS, PubMed and Medline databases. Results: 34 articles that fulfilled all the criteria were selected. Conclusion: The most used techniques, resources and strategies were: anamnesis, physical examination, measurement of pelvic floor muscle activity using Modified Oxford Scale or perineometry, and use of questionnaires to analyze patient's perspective of their own symptoms. Thus, we could use the parameters obtained in the evaluation to plan an ideal PFMT for each patient, so the physiotherapist would have a good database to analyze the evolution and define the end of therapy.

  18. Physical, Complementary, and Alternative Medicine in the Treatment of Pelvic Floor Disorders.

    Science.gov (United States)

    Arnouk, Alex; De, Elise; Rehfuss, Alexandra; Cappadocia, Carin; Dickson, Samantha; Lian, Fei

    2017-06-01

    The purpose of the study was to catalog the most recent available literature regarding the use of conservative measures in treatment of pelvic floor disorders. Pelvic floor disorders encompass abnormalities of urination, defecation, sexual function, pelvic organ prolapse, and chronic pain, and can have significant quality of life implications for patients. Current guidelines recommend behavioral modifications and conservative treatments as first-line therapy for pelvic floor disorders. We have reviewed the literature for articles published on physical, complementary, and alternative treatments for pelvic floor disorders over the past 5 years. Review of pelvic floor muscle physiotherapy (PFMT) and biofeedback (BF) shows a benefit for patients suffering from bladder dysfunction (incontinence, overactive bladder), bowel dysfunction (constipation, fecal incontinence), pelvic organ prolapse, and sexual dysfunction (pelvic pain). Combination of PFMT and BF has shown improved results compared to PFMT alone, and some studies find that electrical stimulation can augment the benefit of BF and PFMT. Additionally, acupuncture and cognitive behavioral therapy has shown to be an effective treatment for pelvic floor disorders, particularly with respect to pelvic pain. This update highlights beneficial conservative treatments available for pelvic floor dysfunction, and supplements the current literature on treatment options for patients suffering from these disorders.

  19. Assessment of pelvic floor dysfunctions using dynamic magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Hoda Salah Darwish

    2014-03-01

    Conclusion: Dynamic MRI is an ideal, non invasive technique which does not require patient preparation for evaluation of pelvic floor. It acts as one stop shop for diagnosing single or multiple pelvic compartment involvement in patients with pelvic floor dysfunction.

  20. Pelvic floor functional disorders in vaginally delivered primiparae

    OpenAIRE

    Antolic, Andrea

    2011-01-01

    In this study we examined pelvic floor functional disorders in primiparae with single pregnancies, cephalic presentation at term at the Charité delivery department before and during pregnancy as well as after vaginal delivery by means of questionnaire in relation to maternal, neonatal and obstetric risk factors. The pathophysiology of pelvic floor disorders is still not statisfyingly resolved. During pregnancy 74% of primiparae knew about the interrelation between delivery and sexual disorde...

  1. Chemical hazards analysis of resilient flooring for healthcare.

    Science.gov (United States)

    Lent, Tom; Silas, Julie; Vallette, Jim

    2010-01-01

    This article addresses resilient flooring, evaluating the potential health effects of vinyl flooring and the leading alternatives-synthetic rubber, polyolefin, and linoleum-currently used in the healthcare marketplace. The study inventories chemicals incorporated as components of each of the four material types or involved in their life cycle as feedstocks, intermediary chemicals, or emissions. It then characterizes those chemicals using a chemical hazard-based framework that addresses persistence and bioaccumulation, human toxicity, and human exposures.

  2. An estimate of the bulk viscosity of the hadronic medium

    Science.gov (United States)

    Sarwar, Golam; Chatterjee, Sandeep; Alam, Jane

    2017-05-01

    The bulk viscosity (ζ) of the hadronic medium has been estimated within the ambit of the Hadron Resonance Gas (HRG) model including the Hagedorn density of states. The HRG thermodynamics within a grand canonical ensemble provides the mean hadron number as well as its fluctuation. The fluctuation in the chemical composition of the hadronic medium in the grand canonical ensemble can result in non-zero divergence of the hadronic fluid flow velocity, allowing us to estimate the ζ of the hadronic matter up to a relaxation time. We study the influence of the hadronic spectrum on ζ and find its correlation with the conformal symmetry breaking measure, ε -3P. We estimate ζ along the contours with constant, S/{N}B (total entropy/net baryon number) in the T-μ plane (temperature-baryonic chemical potential) for S/{N}B=30,45 and 300. We also assess the value of ζ on the chemical freeze-out curve for various centers of mass energy (\\sqrt{{s}{NN}}) and find that the bulk viscosity to entropy density ratio, \\zeta /s is larger in the energy range of the beam energy scan program of RHIC, low energy SPS run, AGS, NICA and FAIR, than LHC energies.

  3. Exact braneworld cosmology induced from bulk black holes

    International Nuclear Information System (INIS)

    Gregory, James P; Padilla, Antonio

    2002-01-01

    We use a new, exact approach in calculating the energy density measured by an observer living on a brane embedded in a charged black-hole spacetime. We find that the bulk Weyl tensor gives rise to nonlinear terms in the energy density and pressure in the FRW equations for the brane. Remarkably, these take exactly the same form as the 'unconventional' terms found in the cosmology of branes embedded in pure AdS, with extra matter living on the brane. Black-hole-driven cosmologies have the benefit that there is no ambiguity in splitting the braneworld energy momentum into tension and additional matter. We propose a new, enlarged relationship between the two descriptions of braneworld cosmology. We also study the exact thermodynamics of the field theory and present a generalized Cardy-Verlinde formula in this set-up

  4. Melt-growth bulk superconductors and application to an axial-gap-type rotating machine

    International Nuclear Information System (INIS)

    Zhang, Yufeng; Zhou, Difan; Ida, Tetsuya; Miki, Motohiro; Izumi, Mitsuru

    2016-01-01

    The present manuscript addresses key issues in the course of our study of materials processing of bulk high-temperature superconductors, trapped flux and its application to a prototype axial-gap-type rotating machine. The TUMSAT group has conducted a series of studies since 2003 on the growth of GdBa 2 Cu 3 O 7−δ bulk material and its application in a compact low-speed high-torque rotating machine. In the stage of material growth, gaining the advantage of a large motive torque density requires large integrated flux in the motor/generators. A large grain surface might be required with sophisticated techniques for the melt-growth texture in the bulk with optimal flux pinning. In the second stage, the in situ magnetization procedure for bulk superconductors in the applied machine is a crucial part of the technology. Pulsed current excitation by using an armature copper winding has magnetized field pole bulks on the rotor. The axial-gap flux synchronous machine studied in the past decade is a condensed technology and indicates that further scientific development is required for a future compact machine to be superior to conventional ones in accordance with the cryogenic periphery and flux stabilization. (paper)

  5. Co-current Doping Effect of Nanoscale Carbon and Aluminum Nitride on Critical Current Density and Flux Pinning Properties of Bulk MgB2 Superconductors

    Science.gov (United States)

    Tripathi, D.; Dey, T. K.

    2018-05-01

    The effect of nanoscale aluminum nitride (n-AlN) and carbon (n-C) co-doping on superconducting properties of polycrystalline bulk MgB2 superconductor has been investigated. Polycrystalline pellets of MgB2, MgB2 + 0.5 wt% AlN (nano), MgB_{1.99}C_{0.01} and MgB_{1.99}C_{0.01} + 0.5 wt% AlN (nano) have been synthesized by a solid reaction process under inert atmosphere. The transition temperature (TC) estimated from resistivity measurement indicates only a small decrease for C (nano) and co-doped MgB2 samples. The magnetic field response of investigated samples has been measured at 4, 10, and 20 K in the field range ± 6 T. MgB2 pellets co-doped with 0.5 wt% n-AlN and 1 wt% n-C display appreciable enhancement in critical current density (J_C) of MgB2 in both low (≥ 3 times), as well as, high-field region (≥ 15 times). J_C versus H behavior of both pristine and doped MgB2 pellets is well explained in the light of the collective pinning model. Further, the normalized pinning force density f_p(= F_p/F_{pmax}) displays a fair correspondence with the scaling procedure proposed by Eisterer et al. Moreover, the scaled data of the pinning force density (i.e., f_p{-}h data) of the investigated pellets at different temperature are well interpreted by a modified Dew-Hughes expression reported by Sandu and Chee.

  6. Quality of life in women with pelvic floor dysfunction

    Directory of Open Access Journals (Sweden)

    Mladenović-Segedi Ljiljana

    2011-01-01

    Full Text Available Background/Aim. Pelvic floor dysfunction is a frequent problem affecting more than 50% of women in peri- and postmenopause. Considering that ageing and menopause befall in the significant factors causing this issue, as well as the expected longevity of women in the world and in our country, pelvic floor dysfunction prevelence is foreseen to be even higher. The aim of the study was to evaluate impact of the symptoms of pelvic dysfunction on quality of life and examine body image satisfaction in adult women with pelvic organ prolapse presenting to tertiary care clinic for surgical treatment. Methods. This prospective case-control study included 50 patients who presented to tertiary care gynecology clinic for surgical treatment and 50 controls with normal pelvic floor support and without urinary incontinence who presented tertiary care gynecology clinic for other reasons. Both, patients and controls, completed two quastionnaires recommended for the evaluation of symptoms (Pelvic floor distress inventory - short forms and quality of life impact (Pelvic floor impact questionnaire - short form of pelvic organ prolapse, and Body Image Scale. Results. The patients scored significantly worse on the prolapse, urinary, colorectal scales and overall score of Pelvic floor distress inventory - 20 than controls subjects (134.91 vs 78.08; p < 0.01. The patients also measured significant decrease in condition- specific quality of life (89.23 vs 3.1; p < 0.01. They were more likely to feel self-conscious (78% vs 42%; p < 0.01, less likely to feel physically attractive (78% vs 22%; p < 0.01, more likely to have difficulty looking at themselves naked (70% vs 42%; p < 0.01, less likely to feel sexually attractive (64% vs 32%; p < 0.01, and less likely to feel feminine (56% vs 16%; p < 0.05, than controls. There were no differencies in their feeling of dissatisfaction with appearance when dressed, avoiding people because of appereance and overall dissatisfaction with

  7. Modelling the cost-effectiveness of impact-absorbing flooring in Swedish residential care facilities.

    Science.gov (United States)

    Ryen, Linda; Svensson, Mikael

    2016-06-01

    Fall-related injuries among the elderly, specifically hip fractures, cause significant morbidity and mortality as well as imposing a substantial financial cost on the health care system. Impact-absorbing flooring has been advocated as an effective method for preventing hip fractures resulting from falls. This study identifies the cost-effectiveness of impact-absorbing flooring compared to standard flooring in residential care facilities for the elderly in a Swedish setting. An incremental cost-effectiveness analysis was performed comparing impact-absorbing flooring to standard flooring using a Markov decision model. A societal perspective was adopted and incremental costs were compared to incremental gains in quality-adjusted life years (QALYs). Data on costs, probability transitions and health-related quality of life measures were retrieved from the published literature and from Swedish register data. Probabilistic sensitivity analysis was performed through a Monte Carlo simulation. The base-case analysis indicates that the impact-absorbing flooring reduces costs and increases QALYs. When allowing for uncertainty we find that 60% of the simulations indicate that impact-absorbing flooring is cost-saving compared to standard flooring and an additional 20% that it has a cost per QALY below a commonly used threshold value : Using a modelling approach, we find that impact-absorbing flooring is a dominant strategy at the societal level considering that it can save resources and improve health in a vulnerable population. © The Author 2015. Published by Oxford University Press on behalf of the European Public Health Association. All rights reserved.

  8. Charge carrier density in Li-intercalated graphene

    KAUST Repository

    Kaloni, Thaneshwor P.; Cheng, Yingchun; Kahaly, M. Upadhyay; Schwingenschlö gl, Udo

    2012-01-01

    The electronic structures of bulk C 6Li, Li-intercalated free-standing bilayer graphene, and Li-intercalated bilayer and trilayer graphene on SiC(0 0 0 1) are studied using density functional theory. Our estimate of Young's modulus suggests that Li

  9. Reaction of calves to two flooring materials offered simultaneously in one pen.

    NARCIS (Netherlands)

    Stefanowska, J.; Swierstra, D.; Smits, A.C.; Berg, van den J.V.; Metz, J.H.M.

    2002-01-01

    Now that group housing is replacing individual crates, so that calves can lie, stand and walk on the pen floor, the quality of the floor for group-housed calves has become the focus of attention. The reaction of two groups of four calves to a double area of floor made from two materials (wooden

  10. In-situ determination of electronic surface and volume defect density of amorphous silicon (a-Si:H) and silicon alloys

    International Nuclear Information System (INIS)

    Siebke, F.

    1992-07-01

    The density of localized gap states in the bulk and in the near-surface region of amorphous hydrogenated silicon (a-Si:H) was measured for non oxidized undoped, B-doped and P-doped samples as well as for films with low carbon (C) and germanium (Ge) content. Also the influence of light soaking on the bulk and surface density of states was investigated. The samples were prepared by rf glow discharge in an UHV-system at substrate temperatures between 100degC and 400degC and transferred to the analysis chamber by a vacuum lock. We combined the constant photocurrent method (CPM) and the total-yield photoelectron spectroscopy (TY) to obtain in-situ information about the defect densities. While the first method yields information about the density of states in the bulk, the other method obtains the density of occupied states in the near-surface region. The mean information depth of the TY-measurements is limited by the escape lenght of photoelectrons and can be estimated to 5 nm. In addition to the defect density the position of the Fermi energy was determined for the bulk by dark conductivity measurements and at the surface using a calibrated Kelvin probe. (orig.)

  11. Statistical analysis of the variation of floor vibrations in nuclear power plants subject to seismic loads

    International Nuclear Information System (INIS)

    Jussila, Vilho; Li, Yue; Fülöp, Ludovic

    2016-01-01

    Highlights: • Floor flexibility plays a non-negligible role in amplifying horizontal vibrations. • COV of in-floor horizontal and vertical acceleration are 0.15–0.25 and 0.25–0.55. • In-floor variation of vibrations is higher in lower floors. • Floor spectra from limited nodes underestimates vibrations by a factor of 1.5–1.75. - Abstract: Floor vibration of a reactor building subjected to seismic loads was investigated, with the aim of quantifying the variability of vibrations on each floor. A detailed 3D building model founded on the bedrock was excited simultaneously in three directions by artificial accelerograms compatible with Finnish ground response spectra. Dynamic simulation for 21 s was carried out using explicit time integration. The extracted results of the simulation were acceleration in several floor locations, transformed to pseudo-acceleration (PSA) spectra in the next stage. At first, the monitored locations on the floors were estimated by engineering judgement in order to arrive at a feasible number of floor nodes for post processing of the data. It became apparent that engineering judgment was insufficient to depict the key locations with high floor vibrations, which resulted in un-conservative vibration estimates. For this reason, a more systematic approach was later considered, in which nodes of the floors were selected with a more refined grid of 2 m. With this method, in addition to the highest PSA peaks in all directions, the full vibration distribution in each floor can be determined. A statistical evaluation of the floor responses was also carried out in order to define floor accelerations and PSAs with high confidence of non-exceedance. The conclusion was that in-floor variability can be as high as 50–60% and models with sufficiently dense node grids should be used in order to achieve a realistic estimate of floor vibration under seismic action. The effects of the shape of the input spectra, damping, and flexibility of the

  12. Statistical analysis of the variation of floor vibrations in nuclear power plants subject to seismic loads

    Energy Technology Data Exchange (ETDEWEB)

    Jussila, Vilho [VTT Technical Research Centre of Finland Ltd, Kemistintie 3, 02230 Espoo (Finland); Li, Yue [Dept. of Civil Engineering, Case Western Reserve University, Cleveland, OH 44106 (United States); Fülöp, Ludovic, E-mail: ludovic.fulop@vtt.fi [VTT Technical Research Centre of Finland Ltd, Kemistintie 3, 02230 Espoo (Finland)

    2016-12-01

    Highlights: • Floor flexibility plays a non-negligible role in amplifying horizontal vibrations. • COV of in-floor horizontal and vertical acceleration are 0.15–0.25 and 0.25–0.55. • In-floor variation of vibrations is higher in lower floors. • Floor spectra from limited nodes underestimates vibrations by a factor of 1.5–1.75. - Abstract: Floor vibration of a reactor building subjected to seismic loads was investigated, with the aim of quantifying the variability of vibrations on each floor. A detailed 3D building model founded on the bedrock was excited simultaneously in three directions by artificial accelerograms compatible with Finnish ground response spectra. Dynamic simulation for 21 s was carried out using explicit time integration. The extracted results of the simulation were acceleration in several floor locations, transformed to pseudo-acceleration (PSA) spectra in the next stage. At first, the monitored locations on the floors were estimated by engineering judgement in order to arrive at a feasible number of floor nodes for post processing of the data. It became apparent that engineering judgment was insufficient to depict the key locations with high floor vibrations, which resulted in un-conservative vibration estimates. For this reason, a more systematic approach was later considered, in which nodes of the floors were selected with a more refined grid of 2 m. With this method, in addition to the highest PSA peaks in all directions, the full vibration distribution in each floor can be determined. A statistical evaluation of the floor responses was also carried out in order to define floor accelerations and PSAs with high confidence of non-exceedance. The conclusion was that in-floor variability can be as high as 50–60% and models with sufficiently dense node grids should be used in order to achieve a realistic estimate of floor vibration under seismic action. The effects of the shape of the input spectra, damping, and flexibility of the

  13. Bulk Densities of Binary Asteroids from the Warm Spitzer NEO Survey

    NARCIS (Netherlands)

    Kistler, John; Trilling, D. E.; Mueller, M.; Hora, J. L.; Harris, A. W.; Bhattacharya, B.; Bottke, W. F.; Chesley, S.; Emery, J. P.; Fazo, G.; Mainzer, A.; Penprase, B.; Smith, H. A.; Spahr, T. B.; Stansberry, J. A.; Thomas, C. A.

    2010-01-01

    The Warm Spitzer NEO survey, ExploreNEOs, will observe approximately 700 Near Earth Asteroids. Several of these objects are known to be binary asteroid systems. Binary systems are interesting due to the unique opportunity they present for determining the masses and densities of their constituent

  14. Low-Impact Flooring: Does It Reduce Fall-Related Injuries?

    Science.gov (United States)

    Hanger, H Carl

    2017-07-01

    To compare fall rates and injuries from falls on low-impact flooring (LIF) compared with a standard vinyl flooring. Prospective, observational, nonrandomized controlled study. Subacute Older Persons Health ward (N = 20 beds). Older inpatients. Three different types of LIF. All falls in the ward were prospectively monitored using incident reporting, noting location and consequences of each fall. Fall rates (per 1000 bed days) and injuries, were compared between bedroom falls on LIF against those occurring on standard vinyl flooring (controls). Over 31 months, there were 278 bedroom falls (from 178 fallers). The bedroom fall rate (falls per 1000 bed days occupied) did not differ between the LIF and control groups (median 15 [IQR 8-18] versus 17 [IQR 9-23], respectively; P = .47). However, fall-related injuries were significantly less frequent when they occurred on LIFs (22% of falls versus 34% of falls on control flooring; P = .02). Fractures occurred in 0.7% of falls in the LIF cohort versus 2.3% in the control cohort. Rolling resistance when moving heavier equipment, such as beds or hoists, was an issue for staff on LIF. LIF significantly reduced fall-related injuries compared with a standard vinyl flooring, whereas they did not alter the overall risk of falling. Copyright © 2017 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  15. Stochastic seismic floor response analysis method for various damping systems

    International Nuclear Information System (INIS)

    Kitada, Y.; Hattori, K.; Ogata, M.; Kanda, J.

    1991-01-01

    A study using the stochastic seismic response analysis method which is applicable for the estimation of floor response spectra is carried out. It is pointed out as a shortcoming in this stochastic seismic response analysis method, that the method tends to overestimate floor response spectra for low damping systems, e.g. 1% of the critical damping ratio. An investigation on the cause of the shortcoming is carried out and a number of improvements in this method were also made to the original method by taking correlation of successive peaks in a response time history into account. The application of the improved method to a typical BWR reactor building is carried out. The resultant floor response spectra are compared with those obtained by deterministic time history analysis. Floor response spectra estimated by the improved method consistently cover the response spectra obtained by the time history analysis for various damping ratios. (orig.)

  16. Hardwood? Carpet? or Tile? A comparison of flooring costs under residential conditions

    Science.gov (United States)

    David G. Martens; David G. Martens

    1971-01-01

    Initial installation cost, annual maintenance cost, and total long-term cost are important in the purchase of flooring products. Before deciding on a flooring material, the prudent buyer will consider each of these in relation to his personal desires. From these evaluations, he will then be able to select the flooring material that is best suited to his individual...

  17. Evaluation of techniques for determining the density of fine woody debris

    Science.gov (United States)

    Becky Fasth; Mark E. Harmon; Christopher W. Woodall; Jay. Sexton

    2010-01-01

    Evaluated various techniques for determining the density (i.e., bulk density) of fine woody debris during forest inventory activities. It was found that only experts in dead wood inventory may be able to identify fine woody debris stages of decay. Suggests various future research directions such as...

  18. Seismic isolation floor and vibration control equipment for nuclear power plant

    International Nuclear Information System (INIS)

    Niwa, H.; Fujimoto, S.; Aida, Y.; Miyano, H.

    1996-01-01

    We have developed a seismic isolation floor to improve protection against earthquakes for process computer systems, and a magnetic dynamic damper to reduce the mechanical vibrations of piping systems and pumps in nuclear power plants. Seismic excitation tests of the seismic isolation floor, on which process computer systems were installed, were performed using large earthquake simulators. The test results proved that the seismic isolation floor significantly reduced seismic forces. To control mechanical vibrations, a magnetic dynamic damper was designed using permanent magnets. This magnetic dynamic damper does not require mechanical springs, dampers and supports in the floors and walls of the building. Vibration tests using a rotating machine model confirmed that the magnetic dynamic damper effectively controlled vibrations in such a rotating machine model. (author)

  19. Modal analysis for floors in lightweight buildings

    DEFF Research Database (Denmark)

    Sjökvist, Lars-Göran; Brunskog, Jonas

    2007-01-01

    of acoustical prediction methods for those houses. The calculation standard EN 12354 is under evaluation since it cannot include most of the wooden houses that are built. It is important during such a work to have a great understanding of the acoustical behaviour for the wooden houses. The floors in lightweight...... constructions usually consist of plates that are stiffened by beams and by the dividing walls. In this study the wave equation for a plate is expanded by Fourier series and an analytical solution in terms of the eigenmodes of the entire system is presented. The studied system consists of one lightweigt floor...

  20. Coatings and floor covers for nuclear applications

    International Nuclear Information System (INIS)

    Kunze, S.

    1998-01-01

    To prevent damage to, or even the destruction of, components of very sensitive electrical equipment in rooms in which unsealed radioactive emitters are handled, floors must be antistatic and capable of being decontaminated. Conductive additives to the cover compounds achieve the desired leakage resistance of 5.10 4 to 10 6 Ω. Investigations have shown the decontamination capability of all floor covers and coatings to be excellent in most cases, and good in a few cases. Except for one coating, the coatings examined after radiation exposure also meet the requirements applying to nuclear installations. (orig.) [de

  1. Effects of floor eggs on hatchability and later life performance in broiler chickens.

    Science.gov (United States)

    van den Brand, H; Sosef, M P; Lourens, A; van Harn, J

    2016-05-01

    Two experiments were conducted in which effects of floor eggs, washed floor eggs, and clean nest eggs were investigated on incubation characteristics and performance in later life of broiler chickens. In both experiments, a young and an older breeder flock were used in a 3×2 factorial design during incubation. In the second experiment, male and female chickens were reared separately until d 35 of age in floor pens. During this grow out trial, an extra group was created in which chickens obtained from clean nest eggs were mixed with chickens obtained from floor eggs, meaning that grow out period was set up as a 4×2×2 factorial design with 4 egg types, 2 breeder ages, and 2 sexes. In both experiments, fertility and hatchability of fertile eggs were lower in floor and washed eggs than in clean nest eggs (hatchability: experiment 1: 74.4 vs. 70.6 vs. 92.6% for floor eggs, washed floor eggs and clean nest eggs, respectively, P<0.001; experiment 2: 78.3 vs. 81.7 vs. 90.2%, respectively, P<0.001). In experiment 2, BW at d 0 of chickens obtained from clean nest eggs was higher than that of chickens from floor eggs and washed floor eggs (41.5 vs. 40.4 and 40.3 g, respectively; P<0.001). This difference disappeared during the grow out period and was absent at slaughter age at d 35 of age. Feed intake (FI), feed conversion ratio (FCR), and mortality during the grow out period were not affected by egg type. Incidence and severity of hock burns and footpad dermatitis were not affected by egg type or breeder age. Litter friability at d 35 of age tended to be lower in pens with chickens obtained from washed floor eggs compared to clean nest eggs. We conclude that incubation of floor eggs or washed floor eggs resulted in lower fertility and hatchability compared to clean nest eggs, but that performance during the grow out period was not affected. © 2016 Poultry Science Association Inc.

  2. [Perioperative nursing of internal sinus floor elevation surgery with piezosurgery].

    Science.gov (United States)

    He, Jing; Lei, Yiling; Wang, Liqiong

    2013-12-01

    This study aims to summarize the nursing experience in the internal sinus floor elevation surgery with piezosurgery. The medical records of 48 patients who underwent sinus floor elevation surgery with piezosurgery in the Department of Implantation, West China Hospital of Stomatology, Sichuan University, were reviewed. The preoperative, intraoperative, and postoperative nursing methods were summarized. All 48 patients underwent smooth surgeries and did not encounter complications. Careful preoperative preparation, careful and meticulous intraoperative nursing cooperation, and provision of sufficient health education after surgery to the patients are the key factors that ensure the success of internal sinus floor elevation surgery with piezosurgery.

  3. Improving the bulk laser-damage resistance of KDP by baking and pulsed-laser irradiation

    International Nuclear Information System (INIS)

    Swain, J.E.; Stokowski, S.E.; Milam, D.; Rainer, F.

    1981-01-01

    Isolated bulk damage centers are produced when KDP crystals are irradiated by 1-ns 1064-nm pulses. We have tested about 100 samples and find the median threshold to be 7 J/cm 2 when the samples are irradiated only once at each test volume (1-on-1 tests). The median threshold increased to 11 J/cm 2 when the test volumes were first subjected to subthreshold laser irradiation (n-on-1 tests). We baked several crystals at temperatures from 110 to 165 0 C and remeasured their thresholds. Baking increased thresholds in some crystals, but did not change thresholds of others. The median threshold of baked crystals ranged from 8 to 10 J/cm 2 depending on the baking temperature. In crystals that had been baked, subthreshold irradiation produced a large change in the bulk damage threshold, and reduced the volume density of damage centers relative to the density observed in unbaked crystals. The data are summarized in the table

  4. Pelvic Muscle Rehabilitation: A Standardized Protocol for Pelvic Floor Dysfunction

    Directory of Open Access Journals (Sweden)

    Rodrigo Pedraza

    2014-01-01

    Full Text Available Introduction. Pelvic floor dysfunction syndromes present with voiding, sexual, and anorectal disturbances, which may be associated with one another, resulting in complex presentation. Thus, an integrated diagnosis and management approach may be required. Pelvic muscle rehabilitation (PMR is a noninvasive modality involving cognitive reeducation, modification, and retraining of the pelvic floor and associated musculature. We describe our standardized PMR protocol for the management of pelvic floor dysfunction syndromes. Pelvic Muscle Rehabilitation Program. The diagnostic assessment includes electromyography and manometry analyzed in 4 phases: (1 initial baseline phase; (2 rapid contraction phase; (3 tonic contraction and endurance phase; and (4 late baseline phase. This evaluation is performed at the onset of every session. PMR management consists of 6 possible therapeutic modalities, employed depending on the diagnostic evaluation: (1 down-training; (2 accessory muscle isolation; (3 discrimination training; (4 muscle strengthening; (5 endurance training; and (6 electrical stimulation. Eight to ten sessions are performed at one-week intervals with integration of home exercises and lifestyle modifications. Conclusions. The PMR protocol offers a standardized approach to diagnose and manage pelvic floor dysfunction syndromes with potential advantages over traditional biofeedback, involving additional interventions and a continuous pelvic floor assessment with management modifications over the clinical course.

  5. Porous 3D graphene-based bulk materials with exceptional high surface area and excellent conductivity for supercapacitors

    Science.gov (United States)

    Zhang, Long; Zhang, Fan; Yang, Xi; Long, Guankui; Wu, Yingpeng; Zhang, Tengfei; Leng, Kai; Huang, Yi; Ma, Yanfeng; Yu, Ao; Chen, Yongsheng

    2013-01-01

    Until now, few sp2 carbon materials simultaneously exhibit superior performance for specific surface area (SSA) and electrical conductivity at bulk state. Thus, it is extremely important to make such materials at bulk scale with those two outstanding properties combined together. Here, we present a simple and green but very efficient approach using two standard and simple industry steps to make such three-dimensional graphene-based porous materials at the bulk scale, with ultrahigh SSA (3523 m2/g) and excellent bulk conductivity. We conclude that these materials consist of mainly defected/wrinkled single layer graphene sheets in the dimensional size of a few nanometers, with at least some covalent bond between each other. The outstanding properties of these materials are demonstrated by their superior supercapacitor performance in ionic liquid with specific capacitance and energy density of 231 F/g and 98 Wh/kg, respectively, so far the best reported capacitance performance for all bulk carbon materials. PMID:23474952

  6. Ab-initio investigation of structural, electronic and optical properties BSb compound in bulk and surface (110 states

    Directory of Open Access Journals (Sweden)

    H A Badehian

    2015-07-01

    Full Text Available In recent work the structural, electronic and optical properties of BSb compound in bulk and surface (110 states have been studied. Calculations have been performed using Full-Potential Augmented Plane Wave (FP-LAPW method by WIEN2k code in Density Functional Theory (DFT framework. The structural properties of the bulk such as lattice constant, bulk module and elastic constants have been investigated using four different approximations. The band gap energy of the bulk and the (110 surface of BSb were obtained about 1.082 and 0.38 eV respectively. Moreover the surface energy, the work function, the surface relaxation, surface state and the band structure of BSb (110 were investigated using symmetric and stoichiometric 15 layers slabs with the vacuum of 20 Bohr. In addition, the real and imaginary parts of the dielectric function of the bulk and the BSb (110 slab were calculated and compared to each other. Our obtained results have a good agreement with the available results.

  7. Methods and Principles of Determining the Footwear and Floor Tribological Characteristics

    Directory of Open Access Journals (Sweden)

    D. Stamenković

    2017-09-01

    Full Text Available There are many standards relating to the anti-slip properties of footwear and flooring. These standards describe the different test methods and procedures for determining the footwear and floor slip resistance in different conditions. In this paper authors systematize the standards in this field applied in the EU and in Serbia and cite the Serbian institutes which are certified for this type of testing. In addition, the authors have carried out an analysis and comparison of the tests that are defined in these standards, indicating their advantages and disadvantages. Importance of the static and kinetic friction testing in determining the anti-slip properties of footwear and flooring is specifically indicated. Considering the current standards in area of slip resistance of the footwear and floor covering authors have determined the testing conditions for laboratory measuring the friction forces of different floor and footwear materials. The laboratory measurement has carried out at Faculty of Mechanical Engineering in Niš. The measuring results and their analysis are presented in the paper, as well.

  8. A density functional approach to ferrogels

    Science.gov (United States)

    Cremer, P.; Heinen, M.; Menzel, A. M.; Löwen, H.

    2017-07-01

    Ferrogels consist of magnetic colloidal particles embedded in an elastic polymer matrix. As a consequence, their structural and rheological properties are governed by a competition between magnetic particle-particle interactions and mechanical matrix elasticity. Typically, the particles are permanently fixed within the matrix, which makes them distinguishable by their positions. Over time, particle neighbors do not change due to the fixation by the matrix. Here we present a classical density functional approach for such ferrogels. We map the elastic matrix-induced interactions between neighboring colloidal particles distinguishable by their positions onto effective pairwise interactions between indistinguishable particles similar to a ‘pairwise pseudopotential’. Using Monte-Carlo computer simulations, we demonstrate for one-dimensional dipole-spring models of ferrogels that this mapping is justified. We then use the pseudopotential as an input into classical density functional theory of inhomogeneous fluids and predict the bulk elastic modulus of the ferrogel under various conditions. In addition, we propose the use of an ‘external pseudopotential’ when one switches from the viewpoint of a one-dimensional dipole-spring object to a one-dimensional chain embedded in an infinitely extended bulk matrix. Our mapping approach paves the way to describe various inhomogeneous situations of ferrogels using classical density functional concepts of inhomogeneous fluids.

  9. Predicting Nanoscale Dynamics of a Glass-Forming Liquid from Its Macroscopic Bulk Behavior and Vice Versa.

    Science.gov (United States)

    Adrjanowicz, Karolina; Kaminski, Kamil; Tarnacka, Magdalena; Szklarz, Grzegorz; Paluch, Marian

    2017-02-02

    The properties of a molecular liquid confined at the nanometer length scale can be very distinct from the bulk. For that reason, the macro- and the nanoscopic behaviors of glass-forming liquids are regarded as two nonconnected realms, governed by their own rules. Here, we show that the glassy dynamics in molecular liquids confined to nanometer pores might obey the density scaling relation, ρ γ /T, just like in bulk fluids. Even more surprisingly, the same value of the scaling exponent γ superposes the α-relaxation time measured at different state points in nanoscale confinement and upon increased pressure. We report this remarkable finding for van der Waals liquids tetramethyl-tetraphenyl-trisiloxane (DC704) and polyphenyl ether (5PPE), considered as simple, single-parameter liquids. Demonstrating that the density scaling idea can be fulfilled in both environments opens an exciting possibility to predict the dynamic features of the nanoconfined system close to its glass-transition temperature from the high-pressure studies of the bulk liquid. Likewise, we can describe the viscous liquid dynamics at any given combination of temperature and pressure based on analysis of its behavior in nanopores.

  10. Rubber Flooring Impact on Production and Herdlife of Dairy Cows

    Science.gov (United States)

    Use of rubber flooring in dairies has become popular because of perceived cow comfort. The overall objective of this longitudinal study was to evaluate production, reproduction, and retention of first and second lactations of cows assigned to either rubber (RUB) or concrete (CON) flooring at the fe...

  11. The Role of Pelvic Floor Muscles in Male Sexual Dysfunction and Pelvic Pain.

    Science.gov (United States)

    Cohen, Deborah; Gonzalez, Joshua; Goldstein, Irwin

    2016-01-01

    Sexual function is essential to good health and well-being in men. The relationship between male sexual function, pelvic floor function, and pelvic pain is complex and only beginning to be appreciated. The objectives of the current review are to examine these complex relationships, and to demonstrate how pelvic floor physical therapy can potentially improve the treatment of various male sexual dysfunctions, including erectile dysfunction and dysfunction of ejaculation and orgasm. Contemporary data on pelvic floor anatomy and function as they relate to the treatment of various male sexual dysfunctions were reviewed. Examination of evidence supporting the association between the male pelvic floor and erectile dysfunction, ejaculatory/orgasmic dysfunction, and chronic prostatitis/chronic pelvic pain syndrome, respectively. Evidence suggests a close relationship between the pelvic floor and male sexual dysfunction and a potential therapeutic benefit from pelvic floor therapy for men who suffer from these conditions. Pelvic floor physical therapy is a necessary tool in a more comprehensive bio-neuromusculoskeletal-psychosocial approach to the treatment of male sexual dysfunction and pelvic pain. Copyright © 2016 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.

  12. Broadband magnetic and density fluctuations in the TCA tokamak

    International Nuclear Information System (INIS)

    Hollenstein, Ch.; Keller, R.; Pochelon, A.; Ryter, F.; Sawley, M.L.; Simm, W.; Weisen, H.

    1987-01-01

    The results of comparative studies of broadband magnetic and density fluctuations during ohmic discharges in the TCA tokamak are described. Long coherence lengths are observed in poloidal and toroidal directions between magnetic probes in the scrape-off layer. A phase contrast diagnostic provides a newly accessible range of density fluctuations in the bulk plasma with very long wavelengths. Langmuir probes provide similar measurements in the scrape-off layer. Statistical dispersion relations for both density and magnetic fluctuations are deduced and are shown to be substantially different. Low mean poloidal wavenumbers (m ∼ 2 at 100 kHz) are obtained for the magnetic fluctuations, in contrast to the much higher values measured for density fluctuations. The difference between magnetic and density fluctuations is also reflected in different scalings with plasma parameters and with electron confinement time. The helicity of the coherent magnetic structures is analyzed to show that interior regions of the plasma, such as the q = 2 region contribute to the magnetic activity at the edge. This explains why the magnetic fluctuations measured at the edge are likely to reflect the confinement properties of the bulk plasma. The results of detailed probe rotation experiments and coherence measurements give indications of the physical nature and origin of magnetic fluctuations

  13. Selection criteria and requirements for floors in nuclear facilities

    International Nuclear Information System (INIS)

    Kunze, S.

    1988-01-01

    As a surface protection of floors in nuclear facilities coatings, rubber and PVC coverings, respectively, are normally used, whereas stoneware tiles are still provided in rare cases only. All floor materials must be well decontaminable according to the German standard DIN 25415, Part 1. The general requirement is that low-porous, smooth products with little filler content, made of chemically resistant material, are very well decontaminable. Further investigations will be necessary for heavily loaded floor coatings. They include above all examinations for decontaminability after radiation and for wear and resistance to chemicals. These requirements have been compiled in DIN 55991. The examination of about 212 industrial products has revealed that the decontaminability of covering materials is frequently poor. Investigations have shown that the decontaminability is always deteriorated by additions of hygroscopic fillers. Additions of non-hygroscopic fillers and pigments may result in an excellent to poor decontaminability. The pore-free bonding of the covering materials by welding or jointing is of great importance with respect to the decontaminability of these floors. Care should be taken that the jointing compounds are as well decontaminable as the rubber coverings and stonewares. (orig.) [de

  14. Selection criteria and requirements for floors in nuclear plants

    International Nuclear Information System (INIS)

    Kunze, S.

    1987-01-01

    As a surface protection of floors in nuclear facilities coatings, rubber and PVC coverings, respectively, are normally used, whereas stoneware tiles are still provided in rare cases only. All floor materials must be well decontaminable according to the German standard DIN 25415, Part 1. The general requirement is that low-porous, smooth products with little filler content, made of chemically resistant material, are very well decontaminable. Further investigations will be necessary for heavily loaded floor coatings. They include above all examinations for decontaminability after radiation and for wear and resistance to chemicals. These requirements have been compiled in DIN 55991. The examination of about 200 industrial products has revealed that the decontaminability of covering materials is frequently poor. Investigations have shown that the decontaminability is always deteriorated by additions of hygroscopic fillers. Additions of non-hygroscopic fillers and pigments may result in an excellent to poor decontaminability. The pore-free bonding of the covering materials by welding or jointing is of great importance with respect to the decontaminability of these floors. Care should be taken that the jointing compounds are as well decontaminable as the rubber coverings and stonewares. (orig.) [de

  15. Virtual reality: new method of teaching anorectal and pelvic floor anatomy.

    Science.gov (United States)

    Dobson, Howard D; Pearl, Russell K; Orsay, Charles P; Rasmussen, Mary; Evenhouse, Ray; Ai, Zhuming; Blew, Gregory; Dech, Fred; Edison, Marcia I; Silverstein, Jonathan C; Abcarian, Herand

    2003-03-01

    A clear understanding of the intricate spatial relationships among the structures of the pelvic floor, rectum, and anal canal is essential for the treatment of numerous pathologic conditions. Virtual-reality technology allows improved visualization of three-dimensional structures over conventional media because it supports stereoscopic-vision, viewer-centered perspective, large angles of view, and interactivity. We describe a novel virtual reality-based model designed to teach anorectal and pelvic floor anatomy, pathology, and surgery. A static physical model depicting the pelvic floor and anorectum was created and digitized at 1-mm intervals in a CT scanner. Multiple software programs were used along with endoscopic images to generate a realistic interactive computer model, which was designed to be viewed on a networked, interactive, virtual-reality display (CAVE or ImmersaDesk). A standard examination of ten basic anorectal and pelvic floor anatomy questions was administered to third-year (n = 6) and fourth-year (n = 7) surgical residents. A workshop using the Virtual Pelvic Floor Model was then given, and the standard examination was readministered so that it was possible to evaluate the effectiveness of the Digital Pelvic Floor Model as an educational instrument. Training on the Virtual Pelvic Floor Model produced substantial improvements in the overall average test scores for the two groups, with an overall increase of 41 percent (P = 0.001) and 21 percent (P = 0.0007) for third-year and fourth-year residents, respectively. Resident evaluations after the workshop also confirmed the effectiveness of understanding pelvic anatomy using the Virtual Pelvic Floor Model. This model provides an innovative interactive educational framework that allows educators to overcome some of the barriers to teaching surgical and endoscopic principles based on understanding highly complex three-dimensional anatomy. Using this collaborative, shared virtual-reality environment

  16. Experimental Investigation of the Influence of Different Flooring Emissivity on Night-Time Cooling using Displacement Ventilation

    DEFF Research Database (Denmark)

    Le Dréau, Jérôme; Karlsen, Line Røseth; Litewnicki, Michal

    2011-01-01

    , but it was seen that the emissivity of the flooring affected the heat transfer ratio at the internal surfaces. The convective heat flux increased at the ceiling and decreased at the floor for experiments with aluminum flooring compared to the experiments with EPS floor. Temperature efficiency was slightly higher......-time ventilation using displacement ventilation. Experimental work was conducted on the basis of the work performed by Artmann et al. (2009) in a similar previous study. An aluminum-foil floor cover was installed in a full scale test room. Experimental results obtained with aluminum flooring were compared...... to results obtained by Artmann et al. with a flooring consisting of expanded polystyrene (EPS). Results showed that the surface temperature of the floor decreased with decreasing emissivity. Mean convective heat fluxes were similar for experiments conducted with both EPS and aluminum-foil floor cover...

  17. Present Status and Future Prospects in Bulk Processing of HIGH-Tc Superconductors

    Science.gov (United States)

    Jin, S.; Chu, C. W.

    The following sections are included: * INTRODUCTION * HIGH SUPERCONDUCTING TRANSITION TEMPERATURE * HIGH CRITICAL CURRENT DENSITY * Grain Boundary Weak Links * Nature of Weak Links * Possible Processing Approaches for Weak Link Problem * Processing Techniques for Texture Formation * Flux Creep in HTSC * Desirable Pinning Defects * Processing for Flux Pinning Enhancement * PROSPECTS FOR BULK APPLICATIONS * Magnetic Field Gener * Energy Storage * Magnetic Shielding * Other Applications * CONCLUDING REMARKS * ACKNOWLEDGMENT * REFERENCES

  18. Design of a New Sensor for Determination of the Effects of Tractor Field Usage in Southern Spain: Soil Sinkage and Alterations in the Cone Index and Dry Bulk Density

    Directory of Open Access Journals (Sweden)

    Diego L. Valera

    2012-10-01

    Full Text Available Variations in sinkage and cone index are of crucial importance when planning fieldwork, and for determining the trafficability of farm machinery. Many studies have highlighted the link between higher values of these parameters and dramatic decreases in crop yield. Variations in the dry bulk density and cone index of clayey soil in Southern Spain were measured following each of five successive passes over the same land with the three types of tractor most widely used in the area (tracked, two-wheel drive and four-wheel drive. In addition, sinkage (rut depth of the running gear was measured using a laser microrelief profile meter. This device, which integrates three sensors, was specifically designed for these experiments, as was an electrical penetrometer to determine the cone index, and both instruments proved reliable and accurate in the field. The main goal of this study was to design, manufacture and test these new devices. The first pass caused most soil alteration when compared to successive passes for all types of tractor tested and soil conditions prevailing during the tests. (Heavier four-wheel drive tractors were found to cause greater soil damage (sinkage, cone index and dry bulk density than two-wheel drive and track tractors. There was no statistically significant difference between the two latter types. The greatest alterations were recorded in the top 10 cm of the soil. The results show that soil compaction should be avoided as much as possible. This can be achieved by ensuring that tractors always travel along the same tracks, especially in the wet season. At present these aspects are not considered by farmers in this area.

  19. A classical density functional investigation of nucleation

    International Nuclear Information System (INIS)

    Ghosh, Satinath; Ghosh, Swapan K.

    2009-01-01

    Study of nucleation and growth phenomena in condensation is of prime importance in various applications such as crystal growth, nanoparticle synthesis, pattern formation etc. The knowledge of nucleation barrier in condensation is necessary to control the nucleation kinetics, size of the nanoparticles etc. Classical nucleation theory (CNT) assumes the density of the drop as bulk density irrespective of the size of the drop and overestimates the nucleation barrier. Here we are interested in solving the problem analytically using density functional theory (DFT) with square gradient approximation along the lines of Cahn and Hilliard. Nucleation barrier and density profile obtained in this work are consistent with other works based on nonclassical theory. (author)

  20. Materials process and applications of single grain (RE)-Ba-Cu-O bulk high-temperature superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Li Beizhan; Zhou Difan; Xu Kun; Hara, Shogo; Tsuzuki, Keita; Miki, Motohiro; Felder, Brice; Deng Zigang [Laboratory of Applied Physics, Department of Marine Electronics and Mechanical Engineering, Tokyo University of Marine Science and Technology (TUMSAT), 2-1-6, Etchu-jima, Koto-ku, Tokyo 135-8533 (Japan); Izumi, Mitsuru, E-mail: izumi@kaiyodai.ac.jp [Laboratory of Applied Physics, Department of Marine Electronics and Mechanical Engineering, Tokyo University of Marine Science and Technology (TUMSAT), 2-1-6, Etchu-jima, Koto-ku, Tokyo 135-8533 (Japan)

    2012-11-20

    This paper reviews recent advances in the melt process of (RE)-Ba-Cu-O [(RE)BCO, where RE represents a rare earth element] single grain high-temperature superconductors (HTSs), bulks and its applications. The efforts on the improvement of the magnetic flux pinning with employing the top-seeded melt-growth process technique and using a seeded infiltration and growth process are discussed. Which including various chemical doping strategies and controlled pushing effect based on the peritectic reaction of (RE)BCO. The typical experiment results, such as the largest single domain bulk, the clear TEM observations and the significant critical current density, are summarized together with the magnetization techniques. Finally, we highlight the recent prominent progress of HTS bulk applications, including Maglev, flywheel, power device, magnetic drug delivery system and magnetic resonance devices.

  1. Materials process and applications of single grain (RE)-Ba-Cu-O bulk high-temperature superconductors

    Science.gov (United States)

    Li, Beizhan; Zhou, Difan; Xu, Kun; Hara, Shogo; Tsuzuki, Keita; Miki, Motohiro; Felder, Brice; Deng, Zigang; Izumi, Mitsuru

    2012-11-01

    This paper reviews recent advances in the melt process of (RE)-Ba-Cu-O [(RE)BCO, where RE represents a rare earth element] single grain high-temperature superconductors (HTSs), bulks and its applications. The efforts on the improvement of the magnetic flux pinning with employing the top-seeded melt-growth process technique and using a seeded infiltration and growth process are discussed. Which including various chemical doping strategies and controlled pushing effect based on the peritectic reaction of (RE)BCO. The typical experiment results, such as the largest single domain bulk, the clear TEM observations and the significant critical current density, are summarized together with the magnetization techniques. Finally, we highlight the recent prominent progress of HTS bulk applications, including Maglev, flywheel, power device, magnetic drug delivery system and magnetic resonance devices.

  2. An experimental investigation of composite floor vibration due to human activities. A case study

    Directory of Open Access Journals (Sweden)

    Yasser G. Mohamed Fahmy

    2012-12-01

    Full Text Available Composite steel floor decks are used in a large variety of constructions with long spans, such as administration and commercial buildings, hotels and bridges. Due to decreased floor mass and longer span lengths, floor vibrations have become an area of concern. Floor decks with low frequencies may be in resonance with the vibrations due to human activities and the resulting acceleration may exceed human comfort levels. The design of slender floor structures, with steel or composite cross sections, is often limited by the serviceability criteria such as deflection limits and vibration behavior, rather than the strength criteria. Control of deflections under AISC specifications requirement is not enough to satisfy the serviceability requirements of the floor systems for vibration. In addition, vibration analysis procedures introduced by AISC design Guide No. 11 are based on regularly-shaped structures and simple boundary conditions. In this paper, a case study for full scale testing of a composite floor system proposed for a tower at Kuwait state that was tested prior to construction. The heel-drop and walking tests are performed on floor systems with and without raised floor respectively. Since heel-drop and walking test results would vary in light of person performance, both tests are carried out three or four times to reduce uncertainty. The fundamental frequencies and damping ratio of the floor system are measured. Comparison of the experimental results with results based on the AISC hand calculations shows that there is no significant difference; therefore the results based on AISC are generally acceptable.

  3. Fabrication of High-performance Sm-Fe-N isotropic bulk magnets by a combination of High-pressure compaction and current sintering

    Energy Technology Data Exchange (ETDEWEB)

    Takagi, Kenta, E-mail: k-takagi@aist.go.jp [Materials Research Institute for Sustainable Development, National Institute of Advanced Industrial Science and Technology (AIST), Nagoya 463-8560 (Japan); Nakayama, Hiroyuki; Ozaki, Kimihiro; Kobayashi, Keizo [Materials Research Institute for Sustainable Development, National Institute of Advanced Industrial Science and Technology (AIST), Nagoya 463-8560 (Japan)

    2012-04-15

    TbCu{sub 7}-type Sm-Fe-N coarse powders in the flake form were consolidated without a bonding medium using a low-thermal-load process of current sintering combined with high-pressure compression. When compacted at 1.2 GPa, the relative density of the powder was increased by 80% with close stacking of the flake particles. Although the subsequent current heating was only briefly performed at a low temperature of 400 Degree-Sign C to avoid decomposition, the compact was consolidated into a rigid bulk in which the particles were bonded at the atomic level. Finally, by using cyclic compaction, this process produced bulk magnets with a density of 92% that exhibited the highest maximum energy product (BH)max of 16.2 MGOe, which surpasses that of conventional isotropic Sm-Fe-N bond magnets. - Highlights: Black-Right-Pointing-Pointer We conduct a consolidation of Sm{sub 1}Fe{sub 7}N bulk magnets without thermal decomposition. Black-Right-Pointing-Pointer Rapid current sintering with high-pressure compaction is used as a low-thermal-load process. Black-Right-Pointing-Pointer In this process, sintering occurs at a temperature of 400 Degree-Sign C, which is below the decomposition point. Black-Right-Pointing-Pointer As a result, bulk magnets with a density of over 92% are obtained without decomposition. Black-Right-Pointing-Pointer These magnets exhibit the highest (BH)max (16.2 MGOe) among isotropic Sm-Fe-N magnets.

  4. Electronic properties and bulk moduli of novel boron nitride polymorphs: hyperdiamond B12N12 and the simple cubic B24N24, B12N12 fulborenites

    International Nuclear Information System (INIS)

    Pokrivnyj, V.V.; Bekenev, V.L.

    2006-01-01

    Equation of states, energy band structure, electronic density of states, and bulk moduli of the boron nitride fulborenite crystals: B 12 N 12 with a diamond lattice and B 24 N 24 , B 12 N 12 with a simple cubic lattice have been calculated for the first time by FLAPW method. Calculated parameters of these compounds are as follows: equilibrium lattice parameter, the length of B-N bond, the number of atoms per conventional cell, density, bulk modulus, band gap. Hyperdiamond B 12 N 12 is shown to have the record bulk modulus B 0 = 658 GPa [ru

  5. Acoustics. Measurement of sound insulation in buildings and of building elements. Laboratory measurements of the reduction of transmitted impact noise by floor coverings on a heavyweight standard floor

    CERN Document Server

    British Standards Institution. London

    1998-01-01

    Acoustics. Measurement of sound insulation in buildings and of building elements. Laboratory measurements of the reduction of transmitted impact noise by floor coverings on a heavyweight standard floor

  6. Total Strain FE Model for Reinforced Concrete Floors on Piles

    NARCIS (Netherlands)

    Hofmeyer, H.; Bos, van den A.A.

    2008-01-01

    A finite element (FE) model using a total strain material model has been developed to predict the behavior of warehouse reinforced concrete floors on piles. The material model (not the FE model itself) was calibrated to material tests. The FE model for the floor structure was checked with full-scale

  7. A route to transparent bulk metals

    KAUST Repository

    Schwingenschlögl, Udo

    2012-07-23

    Hypothetical compounds based on a sapphire host are investigated with respect to their structural as well as electronic features. The results are obtained by electronic structure calculations within density functional theory and the generalized gradient approximation. A quarter of the Al atoms in Al 2O 3 is replaced by a 4d transition metal M ion, with d 0 to d 9 electronic configuration. We perform structure optimizations for all the compounds and analyze the electronic states. Due to the sizeable band gap of the Al 2O 3 host, we can identify promising candidates for transparent bulk metals. We explain the mechanisms leading to this combination of materials properties. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Photoinduced Bulk Polarization and Its Effects on Photovoltaic Actions in Perovskite Solar Cells.

    Science.gov (United States)

    Wu, Ting; Collins, Liam; Zhang, Jia; Lin, Pei-Ying; Ahmadi, Mahshid; Jesse, Stephen; Hu, Bin

    2017-11-28

    This article reports an experimental demonstration of photoinduced bulk polarization in hysteresis-free methylammonium (MA) lead-halide perovskite solar cells [ITO/PEDOT:PSS/perovskite/PCBM/PEI/Ag]. An anomalous capacitance-voltage (CV) signal is observed as a broad "shoulder" in the depletion region from -0.5 to +0.5 V under photoexcitation based on CV measurements where a dc bias is gradually scanned to continuously drift mobile ions in order to detect local polarization under a low alternating bias (50 mV, 5 kHz). Essentially, gradually scanning the dc bias and applying a low alternating bias can separately generate continuously drifting ions and a bulk CV signal from local polarization under photoexcitation. Particularly, when the device efficiency is improved from 12.41% to 18.19% upon chlorine incorporation, this anomalous CV signal can be enhanced by a factor of 3. This anomalous CV signal can be assigned as the signature of photoinduced bulk polarization by distinguishing from surface polarization associated with interfacial charge accumulation. Meanwhile, replacing easy-rotational MA + with difficult-rotational formamidinium (FA + ) cations largely minimizes such anomalous CV signal, suggesting that photoinduced bulk polarization relies on the orientational freedom of dipolar organic cations. Furthermore, a Kelvin probe force microscopy study shows that chlorine incorporation can suppress the density of charged defects and thus enhances photoinduced bulk polarization due to the reduced screening effect from charged defects. A bias-dependent photoluminescence study indicates that increasing bulk polarization can suppress carrier recombination by decreasing charge capture probability through the Coulombic screening effect. Clearly, our studies provide an insightful understanding of photoinduced bulk polarization and its effects on photovoltaic actions in perovskite solar cells.

  9. Prevalence of claw disorders in Dutch dairy cows exposed to several floor systems

    NARCIS (Netherlands)

    Somers, J.G.C.J.; Frankena, K.; Noordhuizen-Stassen, E.N.; Metz, J.H.M.

    2003-01-01

    Claw health was examined in an observational study on Dutch dairy farms with either a slatted floor (SL), slatted floor with manure scraper (SL-SCR), solid concrete floor (SCF), a straw yard (SY), or a zero-grazing feeding system (ZG). Hooves of cows' hind legs were examined for the presence and

  10. The image acquisition system design of floor grinder

    Science.gov (United States)

    Wang, Yang-jiang; Liu, Wei; Liu, Hui-qin

    2018-01-01

    Based on linear CCD, high resolution image real-time acquisition system serves as designing a set of image acquisition system for floor grinder through the calculation of optical imaging system. The entire image acquisition system can collect images of ground before and after the work of the floor grinder, and the data is transmitted through the Bluetooth system to the computer and compared to realize real-time monitoring of its working condition. The system provides technical support for the design of unmanned ground grinders.

  11. Linking chemical elements in forest floor humus (O{sub h}-horizon) in the Czech Republic to contamination sources

    Energy Technology Data Exchange (ETDEWEB)

    Sucharova, Julie; Suchara, Ivan; Hola, Marie [Silva Tarouca Research Institute for Landscape and Ornamental Gardening, Kvetnove namesti 391, 252 43 Pruhonice (Czech Republic); Reimann, Clemens, E-mail: Clemens.Reimann@ngu.no [Geological Survey of Norway, P.O. Box 6315 Sluppen, 7491 Trondheim (Norway); Boyd, Rognvald [Geological Survey of Norway, P.O. Box 6315 Sluppen, 7491 Trondheim (Norway); Filzmoser, Peter [Institute for Statistics and Probability Theory, Vienna University of Technology, Wiedner Hauptstrasse 8-10, 1040 Wien (Austria); Englmaier, Peter [Faculty of Life Science, University of Vienna, Althanstr. 14, A-1090 Vienna (Austria)

    2011-05-15

    While terrestrial moss and other plants are frequently used for environmental mapping and monitoring projects, data on the regional geochemistry of humus are scarce. Humus, however, has a much larger life span than any plant material. It can be seen as the 'environmental memory' of an area for at least the last 60-100 years. Here concentrations of 39 elements determined by ICP-MS and ICP AES, pH and ash content are presented for 259 samples of forest floor humus collected at an average sample density of 1 site/300 km{sup 2} in the Czech Republic. The scale of anomalies linked to known contamination sources (e.g., lignite mining and burning, metallurgical industry, coal fired power plants, metal smelters) is documented and discussed versus natural processes influencing humus quality. Most maps indicate a local impact from individual contamination sources: often more detailed sampling than used here would be needed to differentiate between likely sources. - Highlights: > Concentrations of 39 elements in forest floor humus are provided. > The capabilities of humus sampling for bio-monitoring purposes are demonstrated. > Geochemical anomalies are linked to known contamination sources. > The study shows the importance of scale for geochemical mapping projects. > Humus provides a picture of the long term contamination history of a country. - Forest floor humus, the atmosphere-biosphere-pedosphere interface, archives an environmental contamination signal over long time periods.

  12. Modelling the short-circuit current of polymer bulk heterojunction solar cells

    International Nuclear Information System (INIS)

    Geens, Wim; Martens, Tom; Poortmans, Jef; Aernouts, Tom; Manca, Jean; Lutsen, Laurence; Heremans, Paul; Borghs, Staf; Mertens, Robert; Vanderzande, Dirk

    2004-01-01

    An analytical model has been developed to estimate the short-circuit current density of conjugated polymer/fullerene bulk heterojunction solar cells. The model takes into account the solvent-dependent molecular morphology of the donor/acceptor blend, which was revealed by transmission electron microscopy. Field-effect transistors based on single and composite organic layers were fabricated to determine values for the charge carrier mobilities of such films. These values served as input parameters of the model. It is shown that the difference in short-circuit current density that was measured between toluene-cast and chlorobenzene-cast conjugated polymer/fullerene photovoltaic cells (Appl. Phys. Lett. 78 (2001) 841) could be very well simulated with the model. Moreover, the calculations illustrate how increasing the hole and electron mobilities in the photoactive blend can improve the overall short-circuit current density of the solar cell

  13. Development of Claw Traits and Claw Lesions in Dairy Cows kept on different floor systems

    NARCIS (Netherlands)

    Somers, J.G.C.J.; Schouten, W.G.P.; Frankena, K.; Noordhuizen-Stassen, E.N.; Metz, J.H.M.

    2005-01-01

    Several claw shape measurements, horn hardness, and horn growth and wear were recorded monthly at 12 dairy farms to investigate the effect of floor type and changes in these traits over time. Herds were either housed on a slatted floor (SL), solid concrete floor (SC), grooved floor (GR), or on a

  14. Regulatory Guide 1.122: Development of floor design response spectra for seismic design of floor-supported equipment or components

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    ''Reactor Site Criteria,'' requires, in part, that safety-related structures, systems, and components remain functional in the event of a Safe Shutdown Earthquake (SSE). It specifies the use of a suitable dynamic analysis as one method of ensuring that the structures, systems, and components can withstand the seismic loads. Similarly, paragraph (a)(2) of Section VI of the same appendix requires, in part, that the structures, systems, and components necessary for continued operation without undue risk to the health and safety of the public remain functional in the event of an Operating Basis Earthquake (OBE). Again, the use of suitable dynamic analysis is specified as one method of ensuring that the structures, systems, and components can withstand the seismic loads. This guide describes methods acceptable to the NRC staff for developing two horizontal and one vertical floor design response spectra at various floors or other equipment-support locations of interest from the time-history motions resulting from the dynamic analysis of the supporting structure. These floor design response spectra are needed for the dynamic analysis of the systems or equipment supported at various locations of the supporting structure

  15. [Comparison of pelvic floor muscle strength in competition-level athletes and untrained women].

    Science.gov (United States)

    Ludviksdottir, Ingunn; Hardardottir, Hildur; Sigurdardottir, Thorgerdur; Ulfarsson, Gudmundur F

    2018-01-01

    Exercise can stress the pelvic floor muscles. Numerous women experience urinary incontinence while exercising or competing in sports. This study investigated pelvic floor muscle strength, urinary incontinence, and knowledge in contracting pelvic floor muscles among female athletes and untrained women. This was a prospective case-control study measuring pelvic floor muscle strength using vaginal pressure meas-urement. Participants answered questions regarding general health, urinary incontinence, and knowledge on pelvic floor muscles. Partici-pants were healthy nulliparous women aged 18-30 years, athletes and untrained women. The athletes had competed in their sport for at least three years; including handball, soccer, gymnastics, badminton, BootCamp and CrossFit. The women were comparable in age and height. The athletes (n=18) had a body mass index (BMI) of 22.8 kg/m² vs. 25 kg/m² for the untrained (n=16); p<0.05. The athletes trained on average 11.4 hours/week while the untrained women participated in some activity on average for 1.3 hours/week; p< 0.05. Mean pelvic floor strength was 45±2 hPa in the athletes vs. 43±4 hPa in the untrained; p=0.36 for whether the athletes were stronger. Of the athletes, 61.1% experienced urinary incontinence (n=11) compared with 12.5% of the untrained women (n=2); p<0.05. Incontinence usually occurred during high intensity exercise. The athletes were more knowledgeable about the pelvic floor muscles; p<0.05. There was not a significant difference in the strength of pelvic floor muscles of athletes and untrained women. This suggests that pelvic floor muscles are not strengthened during general training but require specific exercises. This holds especially for football, handball and sports with high physical intensity. Coaches need to pay special attention to training and strengthening women's pelvic floor muscles to reduce the occurrence of urinary incontinence.

  16. Effect of pelvic floor muscle exercises on pulmonary function

    OpenAIRE

    Han, DongWook; Ha, Misook

    2015-01-01

    [Purpose] This study aimed to determine the correlation between pelvic floor muscle strength and pulmonary function. In particular, we examined whether pelvic floor muscle exercises can improve pulmonary function. [Subjects] Thirty female college students aged 19?21 with no history of nervous or musculoskeletal system injury were randomly divided into experimental and control groups. [Methods] For the pulmonary function test, spirometry items included forced vital capacity and maximal volunta...

  17. Timber floors strengthened with concrete

    NARCIS (Netherlands)

    Blass, H.J.; Linden, M.L.R. van der; Schlager, M.

    1998-01-01

    Timber-concrete composite (tcc) beams may be used for the renovation of old timber floors. Although these systems are not new (Pokulka, 1997) and form a simple and practical solution, they are not widely adopted. One of the reasons for this is the Jack of uniform design rules. In this research

  18. Timber-concrete composite floor systems

    NARCIS (Netherlands)

    Linden, M.L.R. van der; Blass, H.J.

    1996-01-01

    Timber-concrete composite (tcc) beams may be used for the renovation of old timber floors. Although these systems are a simple and practical solution, they are not widely adopted. One of the reasons for this is the lack of uniform design mies. In this research programme shear tests on four different

  19. Efficacy of hypopressive abdominal gymnastics in rehabilitating the pelvic floor of women: A systematic review.

    Science.gov (United States)

    Ruiz de Viñaspre Hernández, R

    2017-12-13

    Hypopressive abdominal gymnastics has been proposed as a new paradigm in rehabilitating the pelvic floor. Its claims contraindicate the recommendation for pelvic floor muscle training during the postpartum period. To determine whether hypopressive abdominal gymnastics is more effective than pelvic floor muscle training or other alternative conservative treatments for rehabilitating the pelvic floor. We consulted the databases of the Cumulative Index to Nursing and Allied Health Literature (CINAHL), the Cochrane Library, Latin American and Caribbean Health Sciences Literature (LILACS), Physiotherapy Evidence Database (PEDro), PubMed, Scopus, Trip Database and Web of Science. We selected systematic reviews, clinical trials and analytical studies that assessed the efficacy of hypopressive abdominal gymnastics in women. The measured outcomes were the strengthening of the pelvic floor muscles, the incidence of urine incontinence or prolapse and symptom remission. We included 4 clinical trials, whose quality was measured with the PEDro scale. Hypopressive gymnastics is less effective than pelvic floor muscle training for activating pelvic floor muscles, achieving closure of the levator hiatus of the anus and increasing pelvic floor muscle thickness, strength and resistance. The evidence reviewed does not support the recommendation for hypopressive abdominal gymnastics for strengthening the pelvic floor either during the postpartum period or outside that period. Pelvic floor muscle training remains the first-line treatment for pelvic floor dysfunction. There is a lack of quality clinical trials that have evaluated the efficacy of hypopressive abdominal gymnastics. Copyright © 2017 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Effects of Germanium Tetrabromide Addition to Zinc Tetraphenyl Porphyrin / Fullerene Bulk Heterojunction Solar Cells

    Directory of Open Access Journals (Sweden)

    Atsushi Suzuki

    2014-03-01

    Full Text Available The effects of germanium tetrabromide addition to tetraphenyl porphyrin zinc (Zn-TPP/fullerene (C60 bulk heterojunction solar cells were characterized. The light-induced charge separation and charge transfer were investigated by current density and optical absorption. Addition of germanium tetrabromide inserted into active layer of Zn-TPP/C60 as bulk heterojunction had a positive effect on the photovoltaic and optical properties. The photovoltaic mechanism of the solar cells was discussed by experimental results. The photovoltaic performance was due to light-induced exciton promoted by insert of GeBr4 and charge transfer from HOMO of Zn-TPP to LUMO of C60 in the active layer.

  1. Bulk modulus of CeO2 and PrO2-An experimental and theoretical study

    International Nuclear Information System (INIS)

    Gerward, L.; Staun Olsen, J.; Petit, L.; Vaitheeswaran, G.; Kanchana, V.; Svane, A.

    2005-01-01

    The high-pressure structural behaviour of CeO 2 and PrO 2 has been investigated by synchrotron X-ray diffraction at pressures up to 20 and 35 GPa, respectively. The experiments are accompanied by first principles calculations using the self-interaction corrected local spin density (SIC-LSD) approximation. The experimental values for the zero-pressure bulk modulus of CeO 2 and PrO 2 are 220(9) and 187(8) GPa, respectively. Our calculations reproduce the lattice constants with good accuracy, but find identical bulk modulii for CeO 2 (176.9 GPa) and PrO 2 (176.8 GPa)

  2. Bulk coolant cavitation in LMFBR containment loading following a whole-core explosion

    International Nuclear Information System (INIS)

    Jones, A.V.

    1977-01-01

    An LMFBR core undergoing an explosion transmits energy to the containment in a series of pressure waves and the containment loading is determined by their cumulative effect. These pressure waves are modified by their interaction with the coolant through which they propagate. It is necessary to model both the induction of bulk cavitation by tension waves and the interaction of pressure waves with cavitated liquid in realistic containment loading calculations. This paper sets out the progress which has been achieved in such modelling and first indications for the effect of bulk coolant cavitation in LMFBR containment loading. Conclusions may be briefly summarised: 1) Bulk cavitation must be included in realistic containment loading calculations. 2) Phenomenological models of cavitated liquid without memory are inappropriate. The best approach is to model bubble dynamics directly, including at least momentum conservation and surface tension. 3) The containment loading resulting from a given explosion is sensitive to the state of preparation of the coolant. The number density of nucleation sites should therfore accompany the results of model tests. (Auth.)

  3. High density crystalline boron prepared by hot isostatic pressing in refractory metal containers

    Science.gov (United States)

    Hoenig, C.L.

    1993-08-31

    Boron powder is hot isostatically pressed in a refractory metal container to produce a solid boron monolith with a bulk density at least 2.22 g/cc and up to or greater than 2.34 g/cc. The refractory metal container is formed of tantalum, niobium, tungsten, molybdenum or alloys thereof in the form of a canister or alternatively plasma sprayed or chemical vapor deposited onto a powder compact. Hot isostatic pressing at 1,800 C and 30 PSI (206.8 MPa) argon pressure for four hours produces a bulk density of 2.34 g/cc. Complex shapes can be made.

  4. Effects of maxillary sinus floor elevation surgery on maxillary sinus physiology

    NARCIS (Netherlands)

    Timmenga, NM; Raghoebar, GM; Liem, RSB; van Weissenbruch, R; Manson, WL; Vissink, A

    In a prospective study, the effects of elevation surgery of the maxillary sinus floor on maxillary sinus physiology were assessed. Seventeen consecutive patients without preoperative anamnestic, clinical and radiological signs of maxillary sinusitis underwent sinus floor elevation surgery with iliac

  5. Thermal behaviors of liquid La-based bulk metallic glasses

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, D. W.; Wang, X. D., E-mail: wangxd@zju.edu.cn, E-mail: jiangjz@zju.edu.cn; Lou, H. B.; Cao, Q. P.; Jiang, J. Z., E-mail: wangxd@zju.edu.cn, E-mail: jiangjz@zju.edu.cn [International Center for New-Structured Materials (ICNSM), Laboratory of New-Structured Materials, State Key Laboratory of Silicon Materials, and Department of Materials Science and Engineering, Zhejiang University, Hangzhou 310027 (China); Wang, L. W. [Institute of Materials Science and Engineering, Lanzhou University, Lanzhou 730000 (China); Zhang, D. X. [State Key Laboratory of Modern Optical Instrumentation, Zhejiang University, Hangzhou 310027 (China)

    2014-12-14

    Thermal behaviors of liquid La-based bulk metallic glasses have been measured by using the dilatometer with a self-sealed sample cell. It is demonstrated that the strong glass forming liquid not only has the small thermal expansion coefficient but also shows the slow variation rate. Moreover, the strong glass former has relatively dense atomic packing and also small density change in the liquid state. The results suggest that the high glass forming ability of La-based metallic glasses would be closely related to the slow atomic rearrangements in liquid melts.

  6. The influence of body mass index and gender on the impact attenuation properties of flooring systems.

    Science.gov (United States)

    Bhan, Shivam; Levine, Iris; Laing, Andrew C

    2013-12-01

    The biomechanical effectiveness of safety floors has never been assessed during sideways falls with human volunteers. Furthermore, the influence of body mass index (BMI) and gender on the protective capacity of safety floors is unknown. The purpose of this study was to test whether safety floors provide greater impact attenuation compared with traditional flooring, and whether BMI and gender modify their impact attenuation properties. Thirty participants (7 men and 7 women of low BMI; 7 men and 9 women of high BMI) underwent lateral pelvis release trials on 2 common floors and 4 safety floors. As a group, the safety floors reduced peak force (by up to 11.7%), and increased the time to peak force (by up to 25.5%) compared with a traditional institutional grade floor. Force attenuation was significantly higher for the low BMI group, and for males. Force attenuation was greatest for the low BMI males, averaging 26.5% (SD = 3.0) across the safety floors. These findings demonstrate an overall protective effect of safety floors during lateral falls on the pelvis, but also suggest augmented benefits for frail older adults (often with low body mass) who are at an increased risk of hip fracture.

  7. User Identification Using Gait Patterns on UbiFloorII

    Science.gov (United States)

    Yun, Jaeseok

    2011-01-01

    This paper presents a system of identifying individuals by their gait patterns. We take into account various distinguishable features that can be extracted from a user’s gait and then divide them into two classes: walking pattern and stepping pattern. The conditions we assume are that our target environments are domestic areas, the number of users is smaller than 10, and all users ambulate with bare feet considering the everyday lifestyle of the Korean home. Under these conditions, we have developed a system that identifies individuals’ gait patterns using our biometric sensor, UbiFloorII. We have created UbiFloorII to collect walking samples and created software modules to extract the user’s gait pattern. To identify the users based on the gait patterns extracted from walking samples over UbiFloorII, we have deployed multilayer perceptron network, a feedforward artificial neural network model. The results show that both walking pattern and stepping pattern extracted from users’ gait over the UbiFloorII are distinguishable enough to identify the users and that fusing two classifiers at the matching score level improves the recognition accuracy. Therefore, our proposed system may provide unobtrusive and automatic user identification methods in ubiquitous computing environments, particularly in domestic areas. PMID:22163758

  8. Influence of Bulk Carbonaceous Matter on Pluto's Structure and Evolution

    Science.gov (United States)

    McKinnon, W. B.; Stern, S. A.; Weaver, H. A., Jr.; Spencer, J. R.; Moore, J. M.; Young, L. A.; Olkin, C.

    2017-12-01

    The rock/ice mass ratio of the Pluto system is about 2/1 (McKinnon et al., Icarus 287, 2017) [1], though this neglects the potential role of bulk carbonaceous matter ("CHON"), an important cometary component and one likely important in the ancestral Kuiper belt. The wealth of measurements at comet 67P/Churyumov-Gerasimenko (a Jupiter-family comet and thus one formed in the same region of the outer Solar System as Pluto) by Rosetta are particularly instructive. E.g., Davidsson et al. (A&A 592, 2016) [2] propose in their "composition A" that 67P/Ch-G is 25% metal/sulfides, 42% rock/organics, and 32% ice by mass. For their assumed component densities, the overall grain density is 1820 kg/m3. Fulle et al. (MNRAS 462, 2016) [3] posit 5 ± 2 volume % Fe-sulfides of density 4600 kg/m3, 28 ± 5% Mg,Fe-olivines and -pyroxenes of density 3200 kg/m3, 52 ± 12% hydrocarbons of density 1200 kg/m3, and 15 ± 6% ices of 917 kg/m3. This composition yields a primordial grain density (dust + ice) of 1885 ± 240 kg/m3. Both of these cometary density estimates [2,3] are consistent with Pluto-Charon, especially as Pluto's uncompressed (STP) density is close to 1820 kg/m3 and that of the system as a whole is close to 1800 kg/m3 [1]. We consider the potential compositional and structural implications of these proposed 67P/Ch-G compositions when applied to Pluto and Charon. The amount of ice in model A of [2] is a good match to Pluto structural models. Their rock/organics component, however, is taken to be half graphite (2000 kg/m3) by volume. The composition in [3] is more divergent: very ice poor, and on the order of 50% light hydrocarbons by volume. Regardless of the differences between [2] and [3], the possibility of massive internal graphite or carbonaceous layers within Pluto is real. We discuss the possible consequences for Pluto's structure, rock/ice ratio, thermal and chemical evolution, and even interpretation of its gravity field from tectonics. For example, radiogenic heat

  9. A Summary--The Economics of Carpeting and Resilient Flooring. An Evaluation and Comparison.

    Science.gov (United States)

    Parks, George M.

    Of use to those concerned with the economics of flooring selection and maintenance, this comparison may prove useful as an estimating guide in the preparation of cost estimates for any flooring area where economics is a factor in the choice of materials. All costs attributed to carpet or resilient flooring have been obtained either by survey or…

  10. A Bulk Microphysics Parameterization with Multiple Ice Precipitation Categories.

    Science.gov (United States)

    Straka, Jerry M.; Mansell, Edward R.

    2005-04-01

    A single-moment bulk microphysics scheme with multiple ice precipitation categories is described. It has 2 liquid hydrometeor categories (cloud droplets and rain) and 10 ice categories that are characterized by habit, size, and density—two ice crystal habits (column and plate), rimed cloud ice, snow (ice crystal aggregates), three categories of graupel with different densities and intercepts, frozen drops, small hail, and large hail. The concept of riming history is implemented for conversions among the graupel and frozen drops categories. The multiple precipitation ice categories allow a range of particle densities and fall velocities for simulating a variety of convective storms with minimal parameter tuning. The scheme is applied to two cases—an idealized continental multicell storm that demonstrates the ice precipitation process, and a small Florida maritime storm in which the warm rain process is important.

  11. 76 FR 76690 - Multilayered Wood Flooring From the People's Republic of China: Amended Final Determination of...

    Science.gov (United States)

    2011-12-08

    ... construction or locking joints). All multilayered wood flooring is included within the definition of the... DEPARTMENT OF COMMERCE International Trade Administration [A-570-970] Multilayered Wood Flooring... is issuing an antidumping duty order on multilayered wood flooring (``wood flooring'') from the...

  12. Effect of rubber flooring on group-housed sows' gait and claw and skin lesions.

    Science.gov (United States)

    Bos, E-J; van Riet, M M J; Maes, D; Millet, S; Ampe, B; Janssens, G P J; Tuyttens, F A M

    2016-05-01

    This study evaluated the influence of floor type on sow welfare in terms of lameness, claw lesions, and skin lesions. In a 2 × 3 factorial design, we have investigated the effect of rubber coverings on concrete floors and the effect of 3 levels of dietary zinc supplementation on locomotion and claw and skin lesions in group-housed sows. Six groups of 21 ± 4 hybrid sows were monitored during 3 successive reproductive cycles. The sows were group housed from d 28 after insemination (d 0) until 1 wk before expected farrowing date (d 108) in pens with either exposed concrete floors or concrete floors covered with rubber in part of the lying area and the fully slatted area. During each reproductive cycle, locomotion and skin lesions were assessed 4 times (d 28, 50, 108, and 140) and claw lesions were assessed twice (d 50 and 140). Results are given as least squares means ± SE. Locomotion and claw scores were given in millimeters, on analog scales of 150 and 160 mm, respectively. Here, we report on the effect of floor type, which did not interact with dietary zinc concentration ( > 0.10 for all variables). At move to group (d 28) and mid gestation (d 50), no differences between floor treatments were seen in locomotion ( > 0.10). At the end of gestation (d 108), sows housed on rubber flooring scored 9.9 ± 4.1 mm better on gait ( flooring at mid gestation (d 50). However, sows on rubber flooring scored worse for "vertical cracks in the wall horn" (difference of 3.4 ± 1.7 mm; = 0.04). At the end of lactation (d 140), both "white line" (difference of 2.9 ± 1 mm; = 0.02) and "claw length" (difference of 4.7 ± 1.4 mm; flooring. No differences for skin lesions were observed between floor treatments. The improved scores for gait toward the end of gestation and some types of claw disorders at mid gestation suggest that rubber flooring in group housing has a beneficial effect on the overall leg health of sows. The documented increase in vertical cracks in the wall horn at d

  13. An evaluation of the impact of flooring types on exposures to fine and coarse particles within the residential micro-environment using CONTAM.

    Science.gov (United States)

    Bramwell, Lisa; Qian, Jing; Howard-Reed, Cynthia; Mondal, Sumona; Ferro, Andrea R

    2016-01-01

    Typical resuspension activities within the home, such as walking, have been estimated to contribute up to 25% of personal exposures to PM10. Chamber studies have shown that for moderate walking intensities, flooring type can impact the rate at which particles are re-entrained into the air. For this study, the impact of residential flooring type on incremental average daily (24 h) time-averaged exposure was investigated. Distributions of incremental time-averaged daily exposures to fine and coarse PM while walking within the residential micro-environment were predicted using CONTAM, the multizone airflow and contaminant transport program of the National Institute of Standards and Technology. Knowledge of when and where a person was walking was determined by randomly selecting 490 daily diaries from the EPA's consolidated human activity database (CHAD). On the basis of the results of this study, residential flooring type can significantly impact incremental time-averaged daily exposures to coarse and fine particles (α=0.05, P<0.05, N=490, Kruskal-Wallis test) with high-density cut pile carpeting resulting in the highest exposures. From this study, resuspension from walking within the residential micro-environment contributed 6-72% of time-averaged daily exposures to PM10.

  14. Friction between footwear and floor covered with solid particles under dry and wet conditions.

    Science.gov (United States)

    Li, Kai Way; Meng, Fanxing; Zhang, Wei

    2014-01-01

    Solid particles on the floor, both dry and wet, are common but their effects on the friction on the floor were seldom discussed in the literature. In this study, friction measurements were conducted to test the effects of particle size of solid contaminants on the friction coefficient on the floor under footwear, floor, and surface conditions. The results supported the hypothesis that particle size of solids affected the friction coefficient and the effects depended on footwear, floor, and surface conditions. On dry surfaces, solid particles resulted in friction loss when the Neolite footwear pad was used. On the other hand, solid particles provided additional friction when measured with the ethylene vinyl acetate (EVA) footwear pad. On wet surfaces, introducing solid particles made the floors more slip-resistant and such effects depended on particle size. This study provides information for better understanding of the mechanism of slipping when solid contaminants are present.

  15. Analytical model and application of stress distribution on mining coal floor

    Institute of Scientific and Technical Information of China (English)

    ZHU Shu-yun; JIAN Zhen-quan; HOU Hong-liang; XIAO Wei-guo; YAO Pu

    2008-01-01

    Given the analysis of underground pressure, a stress calculation model of coal floor stress has been established based on a theory of elasticity. The model presents the law of stress distribution on the relatively fixed position of the mining coal floor: the extent of stress variation in a fixed floor position decreases gradually along with depth, the decreasing rate of the vertical stress is clearly larger than that of the horizontal stress at a specific depth. The direction of the maximum principal stress changes gradually from a vertical direction to a horizontal direction with the advance of the working face. The deformation and permeability of the rock mass of the coal floor are obtained by contrasting the difference of the principal stress established from theoretical calculations with curves of stress-strain and permeability-strain from tests, which is an important mechanical basis for preventing water inrush from confined aquifers.

  16. Defect characterization, diagnosis and repair of wood flooring based on a field survey

    International Nuclear Information System (INIS)

    Delgado, A.; Pereira, C.; Brito, J. de; Silvestre, J.D.

    2018-01-01

    A statistical characterization of defects in 35 buildings and 98 wood floorings (softwood and hardwood floors, and laminated and engineered wood floors), their diagnostic methods and repair solutions is presented. An expert system for inspecting wood flooring, comprising the classification of defects, their most probable causes, diagnostic methods and repair techniques, was used. Results include age, affected area, severity and frequency of defects and their main causes, as well as appropriate diagnostic methods, preventive and curative repair solutions most prescribed and the most significant correlations. Scratches were detected in more than five sixths of the sample, highly associated with exterior mechanical actions, and with an inadequate finishing layer. Wearing of the finishing layer was detected in a quarter of the inspected floorings. Accordingly, the application of a suitable finishing layer and, alternatively, its replacement are the most prescribed repair techniques. [es

  17. Trapped magnetic field of a superconducting bulk magnet in high- T sub c RE-Ba-Cu-O

    CERN Document Server

    Fujimoto, H; Higuchi, T; Nakamura, Y; Kamijo, H; Nagashima, K; Murakami, M

    1999-01-01

    Superconducting magnets made of high-T sub c superconductors are promising for industrial applications. It is well known that REBa sub 2 Cu sub 3 O sub 7 sub - sub x and LRE (light rare-earth) Ba sub 2 Cu sub 3 O sub 7 sub - sub x superconductors prepared by melt processes have a high critical current density, J sub c , at 77 K and high magnetic fields. Therefore, the materials are very prospective for high magnetic field application as a superconducting permanent/bulk magnet with liquid-nitrogen refrigeration. LREBaCuO bulks, compared with REBaCuO bulks, exhibit a larger J sub c in high magnetic fields and a much improved irreversibility field, H sub i sub r sub r , at 77 K. In this study, we discuss the possibility and trapped field properties of a superconducting bulk magnet, as well as the melt processing for bulk superconductors and their characteristic superconducting properties. One of the applications is a superconducting magnet for the future magnetically levitated (Maglev) train.

  18. Is Pelvic Floor Muscle Training Effective for Men With Poststroke Lower Urinary Tract Symptoms?

    DEFF Research Database (Denmark)

    Tibaek, Sigrid; Gard, Gunvor; Dehlendorff, Christian

    2017-01-01

    The aim of the current study was to evaluate the effect of pelvic floor muscle training in men with poststroke lower urinary tract symptoms. Thirty-one poststroke men, median age 68 years, were included in this single-blinded randomized controlled trial. Thirty participants, 15 in each group......, completed the study. The intervention consisted of 3 months (12 weekly sessions) of pelvic floor muscle training in groups and home exercises. The effect was evaluated by the DAN-PSS-1 (Danish Prostate Symptom Score) questionnaire, a voiding diary, and digital anal palpation of the pelvic floor muscle...... that pelvic floor muscle training has an effect for lower urinary tract symptoms, although statistical significance was only seen for pelvic floor muscle....

  19. Pelvic Floor Muscle Training: Underutilization in the USA.

    Science.gov (United States)

    Lamin, Eliza; Parrillo, Lisa M; Newman, Diane K; Smith, Ariana L

    2016-02-01

    Pelvic floor disorders are highly prevalent in women of all ages and can greatly impair quality of life. Pelvic floor muscle training (PFMT) is a viable treatment option for several pelvic floor conditions including urinary incontinence and pelvic organ prolapse. PFMT is a program of therapy initiated by an experienced clinician (e.g., women's health or urology nurse practitioner (NP), physical therapist (PT)) that involves exercises for women with stress urinary incontinence (UI) and exercises combined with behavioral or conservative treatments (lifestyle changes, bladder training with urge suppression) for women with urgency or mixed UI. These exercise programs are more comprehensive than simple Kegel exercises. Despite evidence-based research indicating the efficacy and cost-effectiveness for treatment of urinary incontinence, PFMT is not commonly used as a first-line treatment in clinical practice in the USA (Abrams et al., 2012). This article will review PFMT for the treatment of UI and pelvic organ prolapse (POP) and theorize how this conservative therapy can be utilized more effectively in the USA.

  20. Maxillary sinus floor elevation surgery - A clinical, radiographic and endoscopic evaluation

    NARCIS (Netherlands)

    Timmenga, NM; Raghoebar, GM; van Weissenbruch, R; Vissink, A

    Although augmentation of the maxillary sinus floor with autogenous bone grafts has become a well established preimplantology procedure, its effect on the function of the maxillary sinus has not been the subject of prospective human studies. In this prospective study the effects of sinus floor