WorldWideScience

Sample records for flight sinoatrial node

  1. CaMKII in sinoatrial node physiology and dysfunction

    Directory of Open Access Journals (Sweden)

    Yuejin eWu

    2014-03-01

    Full Text Available The calcium and calmodulin dependent protein kinase II (CaMKII is present in sinoatrial node (SAN pacemaker cells and is required for physiological fight or flight SAN beating rate responses. Inhibition of CaMKII in SAN does not affect baseline heart rate, but reduces heart rate increases in response to physiological stress. CaMKII senses intracellular calcium (Ca2+ changes, oxidation status and hyperglycemia to phosphorylate substrates that regulate Ca2+-sensitive proteins, such as L-type Ca2+ channels, phospholamban (PLN, and cardiac ryanodine receptors (RyR2. All of these substrates are involved in the SAN pacemaking mechanism. Excessive CaMKII activity, as occurs under pathological conditions such as heart failure, ischemia and diabetes, can promote intracellular Ca2+ overload and reactive oxygen species (ROS production. Oxidation of CaMKII (ox-CaMKII locks CaMKII into a constitutively active configuration that contributes to SAN cell apoptosis and fibrosis. This ox-CaMKII-mediated loss of functional SAN cells contributes to sinoatrial node dysfunction (SND and sudden death. Thus, CaMKII has emerged as a central regulator of physiological SAN responses and a key determinant of SND.

  2. Sudden fetal death due to dualism of the sino-atrial node.

    Science.gov (United States)

    Pusiol, Teresa; Roncati, Luca; Lavezzi, Anna Maria; Taddei, Fabrizio; Piscioli, Francesco; Ottaviani, Giulia

    2016-01-01

    First, we report a sudden fetal death at 33(+3)weeks due to sino-atrial node dualism. The female stillborn was delivered by induced labor. The postmortem examination of the cardiac conduction system revealed a dualism of the sino-atrial node, associated with fragmentation of the atrio-ventricular node and His bundle. These abnormalities of the cardiac conduction system represent the morphological substrate for the development of malignant arrhythmias. In particular, the dualism of the sino-atrial node can cause the dissociation of the longitudinal nodal impulse into two distinct ways of different pulse generation, resulting in supraventricular tachyarrhythmias. This observation suggests new avenues of research on the pathogenesis of the sudden unexpected fetal death. Moreover, our findings confirm the need for an accurate postmortem examination, including serial sectioning of the cardiac conduction system, in every case of unexplained fetal death, following standardized autoptic protocols. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Biochemical and biomechanical properties of the pacemaking sinoatrial node extracellular matrix are distinct from contractile left ventricular matrix.

    Directory of Open Access Journals (Sweden)

    Jessica M Gluck

    Full Text Available Extracellular matrix plays a role in differentiation and phenotype development of its resident cells. Although cardiac extracellular matrix from the contractile tissues has been studied and utilized in tissue engineering, extracellular matrix properties of the pacemaking sinoatrial node are largely unknown. In this study, the biomechanical properties and biochemical composition and distribution of extracellular matrix in the sinoatrial node were investigated relative to the left ventricle. Extracellular matrix of the sinoatrial node was found to be overall stiffer than that of the left ventricle and highly heterogeneous with interstitial regions composed of predominantly fibrillar collagens and rich in elastin. The extracellular matrix protein distribution suggests that resident pacemaking cardiomyocytes are enclosed in fibrillar collagens that can withstand greater tensile strength while the surrounding elastin-rich regions may undergo deformation to reduce the mechanical strain in these cells. Moreover, basement membrane-associated adhesion proteins that are ligands for integrins were of low abundance in the sinoatrial node, which may decrease force transduction in the pacemaking cardiomyocytes. In contrast to extracellular matrix of the left ventricle, extracellular matrix of the sinoatrial node may reduce mechanical strain and force transduction in pacemaking cardiomyocytes. These findings provide the criteria for a suitable matrix scaffold for engineering biopacemakers.

  4. Metabolic Syndrome Remodels Electrical Activity of the Sinoatrial Node and Produces Arrhythmias in Rats

    Science.gov (United States)

    Albarado-Ibañez, Alondra; Avelino-Cruz, José Everardo; Velasco, Myrian; Torres-Jácome, Julián; Hiriart, Marcia

    2013-01-01

    In the last ten years, the incidences of metabolic syndrome and supraventricular arrhythmias have greatly increased. The metabolic syndrome is a cluster of alterations, which include obesity, hypertension, hypertriglyceridemia, glucose intolerance and insulin resistance, that increase the risk of developing, among others, atrial and nodal arrhythmias. The aim of this study is to demonstrate that metabolic syndrome induces electrical remodeling of the sinus node and produces arrhythmias. We induced metabolic syndrome in 2-month-old male Wistar rats by administering 20% sucrose in the drinking water. Eight weeks later, the rats were anesthetized and the electrocardiogram was recorded, revealing the presence of arrhythmias only in treated rats. Using conventional microelectrode and voltage clamp techniques, we analyzed the electrical activity of the sinoatrial node. We observed that in the sinoatrial node of “metabolic syndrome rats”, compared to controls, the spontaneous firing of all cells decreased, while the slope of the diastolic depolarization increased only in latent pacemaker cells. Accordingly, the pacemaker currents If and Ist increased. Furthermore, histological analysis showed a large amount of fat surrounding nodal cardiomyocytes and a rise in the sympathetic innervation. Finally, Poincaré plot denoted irregularity in the R-R and P-P ECG intervals, in agreement with the variability of nodal firing potential recorded in metabolic syndrome rats. We conclude that metabolic syndrome produces a dysfunction SA node by disrupting normal architecture and the electrical activity, which could explain the onset of arrhythmias in rats. PMID:24250786

  5. Murine transgenic embryonic stem cell lines for the investigation of sinoatrial node-related molecular pathways

    Directory of Open Access Journals (Sweden)

    Stefanie Schmitteckert

    2017-12-01

    Full Text Available The elucidation of molecular mechanisms that restrict the potential of pluripotent stem cells and promote cardiac lineage differentiation is of crucial relevance, since embryonic stem cells (ESCs hold great potential for cell based heart therapies. The homeodomain transcription factor Shox2 is essential for the development and proper function of the native cardiac pacemaker, the sinoatrial node. This prompted us to develop a cardiac differentiation model using ESC lines isolated from blastocysts of Shox2-deficient mice. The established cell model provides a fundamental basis for the investigation of molecular pathways under physiological and pathophysiological conditions for evaluating novel therapeutic approaches.

  6. Características ultra-estruturais do nó sinoatrial de rato Wistar Superstructural features of the wistar strain male rats' sinoatrial node (SAN

    Directory of Open Access Journals (Sweden)

    Carlos Alberto Mandarim de Lacerda

    2002-04-01

    Full Text Available As características ultra-estruturais do nó sinoatrial (NSA de 5 ratos machos da variedade Wistar, com 3 meses de idade, foram estudadas por meio de microscopia eletrônica de transmissão (MET. Fragmento pequeno, contendo a região do NSA e área adjacente do átrio direito do coração, foi retirado e fixado em glutaraldeído 2,5% e processado de acordo com técnica convencional para MET. A morfologia do nó sinoatrial de ratos é semelhante a de outros mamíferos. O NSA é uma estrutura anatômica independente do miocárdio atrial, constituído por células típicas (miócitos nodais, células de transição e, principalmente, células nodais imersos em matriz extracelular, na qual predominam fibras colágenas, fibroblastos e nervosThe superstructural features of five Wistar strain male rats' sinoatrial node (SAN at 3-mo-old were studied through transmission electron microscopy (TEM. Small fragments with the regions containing the SAN were cut off, fixed in glutaraldehyde 2.5% and processed according to the conventional technique for TEM. The morphology of the sinoatrial node of the rats is similar as found in other mammals. The SAN is an independent anatomic structure of the atrial myocardial, constituted of typical cells (nodal myocytes, transition cells and nodal cells principally immersed in the extra cellular matrix where collagen fibers, fibroblasts and nerve predominate

  7. Expression and distribution of voltage-gated ion channels in ferret sinoatrial node.

    Science.gov (United States)

    Brahmajothi, Mulugu V; Morales, Michael J; Campbell, Donald L; Steenbergen, Charles; Strauss, Harold C

    2010-10-01

    Spontaneous diastolic depolarization in the sinoatrial (SA) node enables it to serve as pacemaker of the heart. The variable cell morphology within the SA node predicts that ion channel expression would be heterogeneous and different from that in the atrium. To evaluate ion channel heterogeneity within the SA node, we used fluorescent in situ hybridization to examine ion channel expression in the ferret SA node region and atrial appendage. SA nodal cells were distinguished from surrounding cardiac myocytes by expression of the slow (SA node) and cardiac (surrounding tissue) forms of troponin I. Nerve cells in the sections were identified by detection of GAP-43 and cytoskeletal middle neurofilament. Transcript expression was characterized for the 4 hyperpolarization-activated cation channels, 6 voltage-gated Na(+) channels, 3 voltage-gated Ca(2+) channels, 24 voltage-gated K(+) channel α-subunits, and 3 ancillary subunits. To ensure that transcript expression was representative of protein expression, immunofluorescence was used to verify localization patterns of voltage-dependent K(+) channels. Colocalizations were performed to observe any preferential patterns. Some overlapping and nonoverlapping binding patterns were observed. Measurement of different cation channel transcripts showed heterogeneous expression with many different patterns of expression, attesting to the complexity of electrical activity in the SA node. This study provides insight into the possible role ion channel heterogeneity plays in SA node pacemaker activity.

  8. Controlling parasympathetic regulation of heart rate: a gatekeeperrole for RGS proteins in the sinoatrial node

    Directory of Open Access Journals (Sweden)

    Alexandra eMighiu

    2012-06-01

    Full Text Available Neurotransmitters released from sympathetic and parasympathetic nerve terminals in the SAN exert their effects via G-protein-coupled receptors. Integration of these different G-protein signals within pacemaker cells of the sinoatrial node (SAN is critical for proper regulation of heart rate and function. For example, excessive parasympathetic signaling can be associated with sinus node dysfunction and supraventricular arrhythmias. Our previous work has shown that one member of the regulator of G-protein signaling (RGS protein family, RGS4, is highly and selectively expressed in pacemaker cells of the SAN. Consistent with its role as an inhibitor of parasympathetic signaling, RGS4-knockout mice have reduced basal heart rates and enhanced negative chronotropic responses to parasympathetic agonists. Moreover, RGS4 appears to be an important part of SA nodal myocyte signaling pathways that mediate G protein-coupled inwardly-rectifying potassium channel (GIRK channel activation/deactivation and desensitization. Since RGS4 acts immediately downstream of M2 muscarinic receptors, it is tempting to speculate that RGS4 functions as a master regulator of parasympathetic signaling upstream of GIRKs, HCNs and L-type Ca2+ channels in the SAN. Thus, loss of RGS4 function may lead to increased susceptibility to conditions associated with increased parasympathetic signaling, including bradyarrhythmia, sinus node dysfunction, and atrial fibrillation.

  9. Importance of gradients in membrane properties and electrical coupling in sinoatrial node pacing.

    Directory of Open Access Journals (Sweden)

    Shin Inada

    Full Text Available The sinoatrial node (SAN is heterogeneous in terms of cell size, ion channels, current densities, connexins and electrical coupling. For example, Nav1.5 (responsible for INa and Cx43 (responsible for electrical coupling are absent from the centre of the SAN (normally the leading pacemaker site, but present in the periphery (at SAN-atrial muscle junction. To test whether the heterogeneity is important for the functioning of the SAN, one- and two-dimensional models of the SAN and surrounding atrial muscle were created. Normal functioning of the SAN (in terms of cycle length, position of leading pacemaker site, conduction times, activation and repolarization sequences and space constants was observed when, from the centre to the periphery, (i cell characteristics (cell size and ionic current densities were changed in a gradient fashion from a central-type (lacking INa to a peripheral-type (possessing INa and (ii coupling conductance was increased in a gradient fashion. We conclude that the heterogeneous nature of the node is important for its normal functioning. The presence of Nav1.5 and Cx43 in the periphery may be essential for the node to be able to drive the atrial muscle: Nav1.5 provides the necessary depolarizing current and Cx43 delivers it to the atrial muscle.

  10. Calcium Transient and Sodium-Calcium Exchange Current in Human versus Rabbit Sinoatrial Node Pacemaker Cells

    Directory of Open Access Journals (Sweden)

    Arie O. Verkerk

    2013-01-01

    Full Text Available There is an ongoing debate on the mechanism underlying the pacemaker activity of sinoatrial node (SAN cells, focusing on the relative importance of the “membrane clock” and the “Ca2+ clock” in the generation of the small net membrane current that depolarizes the cell towards the action potential threshold. Specifically, the debate centers around the question whether the membrane clock-driven hyperpolarization-activated current, If, which is also known as the “funny current” or “pacemaker current,” or the Ca2+ clock-driven sodium-calcium exchange current, INaCa, is the main contributor to diastolic depolarization. In our contribution to this journal’s “Special Issue on Cardiac Electrophysiology,” we present a numerical reconstruction of If and INaCa in isolated rabbit and human SAN pacemaker cells based on experimental data on action potentials, If, and intracellular calcium concentration ([Ca2+]i that we have acquired from these cells. The human SAN pacemaker cells have a smaller If, a weaker [Ca2+]i transient, and a smaller INaCa than the rabbit cells. However, when compared to the diastolic net membrane current, INaCa is of similar size in human and rabbit SAN pacemaker cells, whereas If is smaller in human than in rabbit cells.

  11. Distinct patterns of constitutive phosphodiesterase activity in mouse sinoatrial node and atrial myocardium.

    Directory of Open Access Journals (Sweden)

    Rui Hua

    Full Text Available Phosphodiesterases (PDEs are critical regulators of cyclic nucleotides in the heart. In ventricular myocytes, the L-type Ca(2+ current (I(Ca,L is a major target of regulation by PDEs, particularly members of the PDE2, PDE3 and PDE4 families. Conversely, much less is known about the roles of PDE2, PDE3 and PDE4 in the regulation of action potential (AP properties and I(Ca,L in the sinoatrial node (SAN and the atrial myocardium, especially in mice. Thus, the purpose of our study was to measure the effects of global PDE inhibition with Isobutyl-1-methylxanthine (IBMX and selective inhibitors of PDE2, PDE3 and PDE4 on AP properties in isolated mouse SAN and right atrial myocytes. We also measured the effects of these inhibitors on I(Ca,L in SAN and atrial myocytes in comparison to ventricular myocytes. Our data demonstrate that IBMX markedly increases spontaneous AP frequency in SAN myocytes and AP duration in atrial myocytes. Spontaneous AP firing in SAN myocytes was also increased by the PDE2 inhibitor erythro-9-[2-hydroxy-3-nonyl] adenine (EHNA, the PDE3 inhibitor milrinone (Mil and the PDE4 inhibitor rolipram (Rol. In contrast, atrial AP duration was increased by EHNA and Rol, but not by Mil. IBMX also potently, and similarly, increased I(Ca,L in SAN, atrial and ventricular myocytes; however, important differences emerged in terms of which inhibitors could modulate I(Ca,L in each myocyte type. Consistent with our AP measurements, EHNA, Mil and Rol each increased I(Ca,L in SAN myocytes. Also, EHNA and Rol, but not Mil, increased atrial I(Ca,L. In complete contrast, no selective PDE inhibitors increased I(Ca,L in ventricular myocytes when given alone. Thus, our data show that the effects of selective PDE2, PDE3 and PDE4 inhibitors are distinct in the different regions of the myocardium indicating important differences in how each PDE family constitutively regulates ion channel function in the SAN, atrial and ventricular myocardium.

  12. TRPM7 regulates angiotensin II-induced sinoatrial node fibrosis in sick sinus syndrome rats by mediating Smad signaling.

    Science.gov (United States)

    Zhong, Hongbin; Wang, Tingjun; Lian, Guili; Xu, Changsheng; Wang, Huajun; Xie, Liangdi

    2018-03-06

    Sinoatrial node fibrosis is involved in the pathogenesis of sinus sick syndrome (SSS). Transient receptor potential (TRP) subfamily M member 7 (TRPM7) is implicated in cardiac fibrosis. However, the mechanisms underlying the regulation of sinoatrial node (SAN) fibrosis in SSS by TRPM7 remain unknown. The aim of this study was to investigate the role of angiotensin II (Ang II)/TRPM7/Smad pathway in the SAN fibrosis in rats with SSS. The rat SSS model was established with sodium hydroxide pinpoint pressing permeation. Forty-eight rats were randomly divided into six groups: normal control (ctrl), sham operation (sham), postoperative 1-, 2-, 3-, and 4-week SSS, respectively. The tissue explant culture method was used to culture cardiac fibroblasts (CFs) from rat SAN tissues. TRPM7 siRNA or encoding plasmids were used to knock down or overexpress TRPM7. Collagen (Col) distribution in SAN and atria was assessed using PASM-Masson staining. Ang II, Col I, and Col III levels in serum and tissues or in CFs were determined by ELISA. TRPM7, smad2 and p-smad2 levels were evaluated by real-time PCR, and/or western blot and immunohistochemistry. SAN and atria in rats of the SSS groups had more fibers and higher levels of Ang II, Col I and III than the sham rats. Similar findings were obtained for TRPM7 and pSmad2 expression. In vitro, Ang II promoted CFs collagen synthesis in a dose-dependent manner, and potentiated TRPM7 and p-Smad2 expression. TRPM7 depletion inhibited Ang II-induced p-Smad2 expression and collagen synthesis in CFs, whereas increased TRPM7 expression did the opposite. SAN fibrosis is regulated by the Ang II/TRPM7/Smad pathway in SSS, indicating that TRPM7 is a potential target for SAN fibrosis therapy in SSS.

  13. Evidences of the ultrarapid delayed rectifier potassium current (IKur on pacemaker activity in sinoatrial and atrioventricular nodes of Rat

    Directory of Open Access Journals (Sweden)

    Mohammad reza Nikmaram

    2008-09-01

    Full Text Available Background: Sinoatrial node (SAN is the primary pacemaker of the heart. If the SAN activity fails in any way, then the atrioventricular node (AVN immediately starts to regulate the activities of the heart. The aim of this study was to assess the existence or non existence of ultrarapid delayed rectifier potassium current (Ikur and its role on pacemaker activity of two intact SAN and AVN of rat. Methods: The pacemaker activities of distinct intact SAN and AVN by two separate metal microelectrodes that contact the endothelial surface of nodes were recorded and cycle length (CL of action potential was measured. The recording was done before and during 50µM 4-Aminopyridine (4-AP as an Ikur blocker. Results: Compared to control condition, CL of action potentials of SAN and VAN preparations had increased by 17.60 +/-2.9% and 35.90 +/-2.9%, respectively (P<0.05. Conclusion: It is possible to conclude that the Ikur was present in AVN and SAN and the effect of 4-AP on CL of action potential nodes was significantly different.

  14. Long-Term Effects of Atrial Ganglionated Plexi Ablation on Function and Structure of Sinoatrial and Atrioventricular Node in Canine.

    Science.gov (United States)

    Zhang, Ming; Wang, Ximin; Xie, Xinxing; Wang, Zhongsu; Liu, Xiaoyan; Guan, Juan; Wang, Weizong; Li, Zhan; Wang, Jiangrong; Gao, Mei; Hou, Yinglong

    2015-10-01

    Long-term effects of ganglionated plexi (GP) ablation on sinoatrial node (SAN) and atrioventricular node (AVN) remain unclear. This study is to investigate the long-term effects of ablation of cardiac anterior right GP (ARGP) and inferior right GP (IRGP) on function and structure of SAN and AVN in canine. Thirty-two dogs were randomly divided into an operated group (n = 24) and sham-operated group (n = 8). ARGP and IRGP were ablated in operated group which was randomly divided into three subgroups according to the period of evaluation after operation (1 month, 6 months, 12 months). The functional and histological characteristics of SAN and AVN, as well as the expression of connexin (Cx) 43 and Cx 45 in SAN and AVN, were evaluated before and after ablation. Resting heart rate was increased and AVN effective refractory period was prolonged and sinus node recovery time (SNRT) and corrected SNRT were shortened immediately after ablation. These changes were reverted to preablation level after 1 month. At 1 month, ventricular rate during atrial fibrillation was slowed, atria-His intervals were prolonged, and Cx43 and Cx45 expression in SAN and AVN were downregulated. At 6 months, all changes were reverted to preablation level. The histological characteristics of SAN and AVN did not change. Ablation of ARGP and IRGP has short-term effects on function and structure of SAN and AVN rather than long-term effects, which suggests that ablation of ARGP and IRGP is safe. Atrioventricular conduction dysfunction after ablation may be related to downregulated Cx43 and Cx45 expression in AVN. © 2015 Wiley Periodicals, Inc.

  15. Isoprenaline: A Potential Contributor in Sick Sinus Syndrome—Insights from a Mathematical Model of the Rabbit Sinoatrial Node

    Directory of Open Access Journals (Sweden)

    Xiang Li

    2014-01-01

    Full Text Available The mechanism of isoprenaline exerting its effects on cardiac pacemaking and driving in sick sinus syndrome is controversial and unresolved. In this paper, mathematical models for rabbit sinoatrial node cells were modified by incorporating equations for the known dose-dependent actions of isoprenaline on various ionic channel currents, the intracellular Ca2+ transient, and iNa changes induced by SCN5A gene mutations; the cell models were also incorporated into an intact SAN-atrium model of the rabbit heart that is based on both heterogeneities of the SAN electrophysiology and histological structure. Our results show that, in both central and peripheral cell models, isoprenaline could not only shorten the action potential duration, but also increase the amplitude of action potential. The mutation impaired the SAN pacemaking. Simulated vagal nerve activity amplified the bradycardic effects of the mutation. However, in tissue case, the pacemaker activity may show temporal, spatial, or even spatiotemporal cessation caused by the mutation. Addition of isoprenaline could significantly diminish the bradycardic effect of the mutation and the SAN could restart pacing and driving the surrounding tissue. Positive effects of isoprenaline may primarily be attributable to an increase in iNa and iCa,T which were reduced by the mutation.

  16. The functions of atrial strands interdigitating with and penetrating into sinoatrial node: a theoretical study of the problem.

    Directory of Open Access Journals (Sweden)

    Xiaodong Huang

    Full Text Available The sinoatrial node (SAN-atrium system is closely involved with the activity of heart beating. The impulse propagation and phase-locking behaviors of this system are of theoretical interest. Some experiments have revealed that atrial strands (ASs interdigitate with and penetrate into the SAN, whereby the SAN-atrium system works as a complex network. In this study, the functions of ASs are numerically investigated using realistic cardiac models. The results indicate that the ASs penetrating into the central region of the SAN play a major role in propagating excitation into the atrium. This is because the threshold SAN-AS coupling for an AS to function as an alternative path for propagation is lower at the center than at the periphery. However, ASs penetrating into the peripheral region have a great effect in terms of enlarging the 1:1 entrainment range of the SAN because the automaticity of the SAN is evidently reduced by ASs. Moreover, an analytical formula for approximating the enlargement of the 1:1 range is derived.

  17. Phase dependency of electrotonic spread of hyperpolarizing current pulses in the rabbit sinoatrial node

    NARCIS (Netherlands)

    Duivenvoorden, J. J.; Bouman, L. N.; Bukauskas, F. F.; Opthof, T.; Jongsma, H. J.

    1990-01-01

    Electrotonic current spread in the SA node of the rabbit was measured by means of hyperpolarizing current pulses (1 to 10 microA, 60 ms), which were injected intracellularly through a K(+)-perfused suction electrode. The pulses were applied at the beginning, middle or end of the diastolic

  18. Análise comparativa entre a vascularização arterial ventricular e do nó sinoatrial em corações de cães Comparative analysis between both ventricular and sinoatrial node arterial vascularization in heart of dogs

    Directory of Open Access Journals (Sweden)

    Caio Biasi

    2013-01-01

    vascularization the left coronary artery was predominant and gave rise to the paraconal interventricular and subsinuous branches. The region occupied by the sinoatrial node was most frequently (17 times, 42.5% in dependence of the left atrial proximal branch or in the collateral branch of that vessel, coming from the left circumflex branch, or this vessel was associated with the right atrial distal branch (8 times, 20%. With less frequency (14 times, 30%, in the area occupied by the sinoatrial node we found only the collaterals of the right circumflex branch, only the right atrial distal branch (10 times, 25%, only the right atrial proximal branch (3 times, 7.5% or exclusively the right atrial intermediary branch (once, 2.5%. In just one case (once, 2.5% in the area of the sinoatrial node we observed only the collateral of the left circumflex branch, i.e. the left atrial distal branch. According to our results we concluded that in this specie there is no relationship between the type of ventricular vascularization and irrigation of the sinoatrial node. In doing so, to consider just the ventricular branches is not sufficient for a clinical and surgical applied understanding, since the atrial branches make an important contribution to the sinoatrial node vascularization.

  19. Contribution of small conductance K+ channels to sinoatrial node pacemaker activity: insights from atrial-specific Na+ /Ca2+ exchange knockout mice.

    Science.gov (United States)

    Torrente, Angelo G; Zhang, Rui; Wang, Heidi; Zaini, Audrey; Kim, Brian; Yue, Xin; Philipson, Kenneth D; Goldhaber, Joshua I

    2017-06-15

    Repolarizing currents through K + channels are essential for proper sinoatrial node (SAN) pacemaking, but the influence of intracellular Ca 2+ on repolarization in the SAN is uncertain. We identified all three isoforms of Ca 2+ -activated small conductance K + (SK) channels in the murine SAN. SK channel blockade slows repolarization and subsequent depolarization of SAN cells. In the atrial-specific Na + /Ca 2+ exchanger (NCX) knockout mouse, cellular Ca 2+ accumulation during spontaneous SAN pacemaker activity produces intermittent hyperactivation of SK channels, leading to arrhythmic pauses alternating with bursts of pacing. These findings suggest that Ca 2+ -sensitive SK channels can translate changes in cellular Ca 2+ into a repolarizing current capable of modulating pacemaking. SK channels are a potential pharmacological target for modulating SAN rate or treating SAN dysfunction, particularly under conditions characterized by abnormal increases in diastolic Ca 2+ . Small conductance K + (SK) channels have been implicated as modulators of spontaneous depolarization and electrical conduction that may be involved in cardiac arrhythmia. However, neither their presence nor their contribution to sinoatrial node (SAN) pacemaker activity has been investigated. Using quantitative PCR (q-PCR), immunostaining and patch clamp recordings of membrane current and voltage, we identified all three SK isoforms (SK1, SK2 and SK3) in mouse SAN. Inhibition of SK channels with the specific blocker apamin prolonged action potentials (APs) in isolated SAN cells. Apamin also slowed diastolic depolarization and reduced pacemaker rate in isolated SAN cells and intact tissue. We investigated whether the Ca 2+ -sensitive nature of SK channels could explain arrhythmic SAN pacemaker activity in the atrial-specific Na + /Ca 2+ exchange (NCX) knockout (KO) mouse, a model of cellular Ca 2+ overload. SAN cells isolated from the NCX KO exhibited higher SK current than wildtype (WT) and apamin

  20. Calsequestrin 2 deletion causes sinoatrial node dysfunction and atrial arrhythmias associated with altered sarcoplasmic reticulum calcium cycling and degenerative fibrosis within the mouse atrial pacemaker complex1

    Science.gov (United States)

    Glukhov, Alexey V.; Kalyanasundaram, Anuradha; Lou, Qing; Hage, Lori T.; Hansen, Brian J.; Belevych, Andriy E.; Mohler, Peter J.; Knollmann, Björn C.; Periasamy, Muthu; Györke, Sandor; Fedorov, Vadim V.

    2015-01-01

    Aims Loss-of-function mutations in Calsequestrin 2 (CASQ2) are associated with catecholaminergic polymorphic ventricular tachycardia (CPVT). CPVT patients also exhibit bradycardia and atrial arrhythmias for which the underlying mechanism remains unknown. We aimed to study the sinoatrial node (SAN) dysfunction due to loss of CASQ2. Methods and results In vivo electrocardiogram (ECG) monitoring, in vitro high-resolution optical mapping, confocal imaging of intracellular Ca2+ cycling, and 3D atrial immunohistology were performed in wild-type (WT) and Casq2 null (Casq2−/−) mice. Casq2−/− mice exhibited bradycardia, SAN conduction abnormalities, and beat-to-beat heart rate variability due to enhanced atrial ectopic activity both at baseline and with autonomic stimulation. Loss of CASQ2 increased fibrosis within the pacemaker complex, depressed primary SAN activity, and conduction, but enhanced atrial ectopic activity and atrial fibrillation (AF) associated with macro- and micro-reentry during autonomic stimulation. In SAN myocytes, CASQ2 deficiency induced perturbations in intracellular Ca2+ cycling, including abnormal Ca2+ release, periods of significantly elevated diastolic Ca2+ levels leading to pauses and unstable pacemaker rate. Importantly, Ca2+ cycling dysfunction occurred not only at the SAN cellular level but was also globally manifested as an increased delay between action potential (AP) and Ca2+ transient upstrokes throughout the atrial pacemaker complex. Conclusions Loss of CASQ2 causes abnormal sarcoplasmic reticulum Ca2+ release and selective interstitial fibrosis in the atrial pacemaker complex, which disrupt SAN pacemaking but enhance latent pacemaker activity, create conduction abnormalities and increase susceptibility to AF. These functional and extensive structural alterations could contribute to SAN dysfunction as well as AF in CPVT patients. PMID:24216388

  1. Vascularização arterial da região do nó sinoatrial em corações suínos: origem, distribuição e quantificação Arterial vascularization of the sinoatrial node in swine hearts: origin, distribution and quantification

    Directory of Open Access Journals (Sweden)

    Ana P. Vidotti

    2008-02-01

    superfície de área (Sv foi de 182 e a superfície de área (S - mm² - foi de 64,3x10(6µm². A estimação da densidade numérica vascular (Nv(vasc, quantidade de vasos por unidade de volume (cm³, foi de 2,19 10-5 e o número total de vasos no órgão (N(vasc, estimado pelo método dissector físico em combinação com a estimativa do número de Euler (Xv, foi de 773,6832 x10-2. A elevada densidade vascular e do número total de vasos na região do nó sinoatrial de suínos sugere a existência de uma complexa e densa rede vascular perinodal, ratificando a importância deste marca-passo pelo seu suprimento sangüíneo.The sinoatrial node, for being topographically installed as the initial component of the conduction system, is responsible for the production of the nervous impulses, which determines the cardiac contraction. There have been made studies related to the node's morphology in order to know the origin, distribution and quantification of the vases in this tissue, however, in spite of the results and quantitative data of the nodal irrigation - arterial vascular conduct and arterial vascular density, at the nodal level - the literature is scarce. With this objective 27 SRD swine hearts, injected with colored resin for macroscopic analysis of the origin and distribution of ANSA (sinoatrial node artery, 3 others injected with watery solution of colloidal coal (dyed nanquim were used, to mark the route of the vases on the node level for stereological analysis. The atrial arteries originated as well from the right coronary artery as from the left one, with predominance of the first (66.66% and 33.33%, respectively. When originated from the right coronary artery, there existed the following branches: AADAM (right cranial medial atrial artery in 14 cases, AADAI (right cranial intermedial atrial artery in 2 cases, and AADAL (right cranial lateral atrial artery in 2 cases. In 9 cases (33.33% the following branches originated from the left coronary artery: 4 through

  2. Anatomical Variations in the Sinoatrial Nodal Artery: A Meta-Analysis and Clinical Considerations.

    Directory of Open Access Journals (Sweden)

    Jens Vikse

    Full Text Available The sinoatrial nodal artery (SANa is a highly variable vessel which supplies blood to the sinoatrial node (SAN. Due to its variability and susceptibility to iatrogenic injury, our study aimed to assess the anatomy of the SANa and determine the prevalence of its anatomical variations.An extensive search of major electronic databases was performed to identify all articles reporting anatomical data on the SANa. No lower date limit or language restrictions were applied. Anatomical data regarding the artery were extracted and pooled into a meta-analysis.Sixty-six studies (n = 21455 hearts were included in the meta-analysis. The SANa usually arose as a single vessel with a pooled prevalence of 95.5% (95%CI:93.6-96.9. Duplication and triplication of the artery were also observed with pooled prevalence of 4.3% (95%CI:2.8-6.0 and 0.3% (95%CI:0-0.7, respectively. The most common origin of the SANa was from the right coronary artery (RCA, found in 68.0% (95%CI:55.6-68.9 of cases, followed by origin from the left circumflex artery, and origin from the left coronary artery with pooled prevalence of 22.1% (95%CI:15.0-26.2 and 2.7 (95%CI:0.7-5.2, respectively. A retrocaval course of the SANa was the most common course of the artery with a pooled prevalence of 47.1% (95%CI:36.0-55.5. The pooled prevalence of an S-shaped SANa was 7.6% (95%CI:2.9-14.1.The SANa is most commonly reported as a single vessel, originating from the RCA, and taking a retrocaval course to reach the SAN. Knowledge of high risk anatomical variants of the SANa, such as an S-shaped artery, must be taken into account by surgeons to prevent iatrogenic injuries. Specifically, interventional or cardiosurgical procedures, such as the Cox maze procedure for atrial fibrillation, open heart surgeries through the right atrium or intraoperative cross-clamping or dissection procedures during mitral valve surgery using the septal approach can all potentiate the risk for injury in the setting of high

  3. Pathophysiological mechanisms of sino-atrial dysfunction and ventricular conduction disease associated with SCN5A deficiency: insights from mouse models

    Directory of Open Access Journals (Sweden)

    Christopher L-H Huang

    2012-07-01

    Full Text Available Genetically modified mice provide a number of models for studying cardiac channelopathies related to cardiac Na+ channel (SCN5A abnormalities. We review key pathophysiological features in these murine models that may underlie clinical features observed in sinus node dysfunction and progressive cardiac conduction disease, thereby providing insights into their pathophysiological mechanisms. We describe loss of Na+ channel function and fibrotic changes associated with both loss and gain-of-function Na+ channel mutations. Recent reports further relate the progressive fibrotic changes to upregulation of TGF-β1 production and the transcription factors, Atf3, a stress-inducible gene, and Egr1, to the presence of heterozygous Scn5a inactivation. Both changes are thus directly implicated in the clinically observed disruptions in sino-atrial node pacemaker function, and sino-atrial and ventricular conduction, and their progression with age. Murine systems with genetic modifications in Scn5a thus prove a useful tool to address questions concerning roles of genetic and environmental modifiers on human SCN5A disease phenotypes.

  4. Effects of Acetylcholine and Noradrenalin on Action Potentials of Isolated Rabbit Sinoatrial and Atrial Myocytes

    Science.gov (United States)

    Verkerk, Arie O.; Geuzebroek, Guillaume S. C.; Veldkamp, Marieke W.; Wilders, Ronald

    2012-01-01

    The autonomic nervous system controls heart rate and contractility through sympathetic and parasympathetic inputs to the cardiac tissue, with acetylcholine (ACh) and noradrenalin (NA) as the chemical transmitters. In recent years, it has become clear that specific Regulators of G protein Signaling proteins (RGS proteins) suppress muscarinic sensitivity and parasympathetic tone, identifying RGS proteins as intriguing potential therapeutic targets. In the present study, we have identified the effects of 1 μM ACh and 1 μM NA on the intrinsic action potentials of sinoatrial (SA) nodal and atrial myocytes. Single cells were enzymatically isolated from the SA node or from the left atrium of rabbit hearts. Action potentials were recorded using the amphotericin-perforated patch-clamp technique in the absence and presence of ACh, NA, or a combination of both. In SA nodal myocytes, ACh increased cycle length and decreased diastolic depolarization rate, whereas NA decreased cycle length and increased diastolic depolarization rate. Both ACh and NA increased maximum upstroke velocity. Furthermore, ACh hyperpolarized the maximum diastolic potential. In atrial myocytes stimulated at 2 Hz, both ACh and NA hyperpolarized the maximum diastolic potential, increased the action potential amplitude, and increased the maximum upstroke velocity. Action potential duration at 50 and 90% repolarization was decreased by ACh, but increased by NA. The effects of both ACh and NA on action potential duration showed a dose dependence in the range of 1–1000 nM, while a clear-cut frequency dependence in the range of 1–4 Hz was absent. Intermediate results were obtained in the combined presence of ACh and NA in both SA nodal and atrial myocytes. Our data uncover the extent to which SA nodal and atrial action potentials are intrinsically dependent on ACh, NA, or a combination of both and may thus guide further experiments with RGS proteins. PMID:22754533

  5. Variaciones de la arteria del nodo sinoatrial en población colombiana

    Directory of Open Access Journals (Sweden)

    Yobany Quijano Blanco

    2012-01-01

    Full Text Available Antecedentes. El conocimiento exacto de la integración anatomofisiológica del sistema de conducción del corazón, es fundamental para la comprender la fisiopatología, el diagnóstico y el manejo de muchas de las complicaciones de la enfermedad coronaria y de las cardiopatías en general. Uno de los aspectos fundamentales, más variable y con mayores repercusiones clínicas corresponde al origen y recorrido de las arterias encargadas de irrigar el nódulo sinoatrial. Objetivo. Determinar el origen, recorrido y distribución de las arterias que irrigan el nódulo sinoatrial en una muestra de población colombiana.  Material y métodos. La muestra de análisis fueron 60 bloques cardiopulmonares y digestivos seleccionados a través de muestreo por conveniencia. A estos se les realizó una disección convencional de los genitales para la determinación del sexo y posteriormente se procedió con la disección de las arterias coronarias específicamente de la arteria del nódulo sinoatrial, con el fin de establecer su origen y recorrido. Resultados. Como hallazgo principal se encontró que el origen de la arteria del nódulo sinoatrial en 75% provenía  de la coronaria derecha, un 15% procedía de la arteria circunfleja y el 10% restante fue codominante. En cuanto al trayecto 86,6% fueron lineales, mientras 13,4% tuvieron formas alternas como Y, doble Y o en tridente. Conclusiones. Se evidenció predominio del  origen de la arteria del nódulo sinoatrial en la coronaria derecha, hallazgo coincidente con investigaciones similares e independiente de la procedencia geográfica y el origen racial. Sin embargo, en este estudio se evidenciaron  recorridos no reportados en la literatura como la distribución en Y, en doble Y, en K invertida y en tridente.

  6. Estudo prospectivo das repercussões de baixas doses de remifentanil na função sinoatrial e na condução e refratariedade cardíaca Estudio prospectivo de las repercusiones de bajas dosis de remifentanil en la función sinoatrial en la conducción y refractariedad cardiaca Prospective study on the repercussions of low doses of remifentanil on sinoatrial function and in cardiac conduction and refractory period

    Directory of Open Access Journals (Sweden)

    Simone Soares Leite

    2007-10-01

    recuperación del nódulo sino-atrial (p = 0,0004, del período refractario del atrio derecho (p = 0,001 y del período refractario del nódulo atrio ventricular (p = 0,0001, pero no hubo disminución de la frecuencia cardíaca basal entre M0 e M1. CONCLUSIONES: El remifentanil altero las variables electrofisiológicas cardíacas, lo que en dosis mayores que las estudiadas podría causar bradicardia sinusal, asistolia y disturbios de conducción.BACKGROUND AND OBJECTIVES: Remifentanil is an opiod with fast onset of action and short acting, and its use in short-duration procedures has increased in the last few years. Bradycardia and asystole are among the side effects reported. The objective of this study was to evaluate the effects of this drug in cardiac conduction and refractory period in human beings. METHODS: A prospective study with 16 patients, ages 18 to 65, both genders, ASA I to III, undergoing elective intracardiac electrophysiological study, was undertaken. Patients with disorders of the sinoatrial node and those with severe cardiac blocks were excluded. In the laboratory of electrophysiology, patients were sedated with midazolam (0.03 mg.kg-1 after 5 minutes the degree of sedation and degree of pain, systolic and diastolic blood pressure, heart rate and respiratory rate, and oxygen saturation were evaluated. The electrophysiologist evaluated cardiac conduction (duration of the QRS complex, and AA, AH, HV, and PA intervals, duration of sinoatrial node recovery, and cardiac refractory period (refractory period of the right atrium, right ventricle, and atrioventricular node. After the initial measurements, remifentanil was administered (bolus of 0.5 µg.kg-1 + infusion of 0.05 µg.kg-1.min-1 and, after 20 minutes, the same parameters were evaluated. RESULTS: There was a reduction in systolic and diastolic blood pressure (p = 0.0001 between M0 and M1, and significant differences in respiratory rate and oxygen saturation, which were not statistically significant. The

  7. Flight Tests of a 0.13-Scale Model of the Convair XFY-1 Vertically Rising Airplane with the Lower Vertical Tail Removed, TED No.DE 368

    Science.gov (United States)

    Lovell, Powell M., Jr.

    1954-01-01

    An experimental investigation has been conducted to determine the dynamic stability and control characteristics in hovering and transition flight of a 0.13-scale flying model of the Convair XFY-1 vertically rising airplane with the lower vertical tail removed. The purpose of the tests was to obtain a general indication of the behavior of a vertically rising airplane of the same general type as the XFY-1 but without a lower vertical tail in order to simplify power-off belly landings in an emergency. The model was flown satisfactorily in hovering flight and in the transition from hovering to normal unstalled forward flight (angle of attack approximately 30deg). From an angle of attack of about 30 down to the lowest angle of attack covered in the flight tests (approximately 15deg) the model became progressively more difficult to control. These control difficulties were attributed partly to a lightly damped Dutch roll oscillation and partly to the fact that the control deflections required for hovering and transition flight were too great for smooth flight at high speeds. In the low-angle-of-attack range not covered in the flight tests, force tests have indicated very low static directional stability which would probably result in poor flight characteristics. It appears, therefore, that the attainment of satisfactory directional stability, at angles of attack less than 10deg, rather than in the hovering and transition ranges of flight is the critical factor in the design of the vertical tail for such a configuration.

  8. Node cookbook

    CERN Document Server

    Clements, David Mark

    2014-01-01

    In Node Cookbook Second Edition, each chapter focuses on a different aspect of working with Node. Following a Cookbook structure, the recipes are written in an easy-to-understand language. Readers will find it easier to grasp even the complex recipes which are backed by lots of illustrations, tips, and hints.If you have some knowledge of JavaScript and want to build fast, efficient, scalable client-server solutions, then Node Cookbook Second Edition is for you. Knowledge of Node will be an advantage but is not required. Experienced users of Node will be able to improve their skills.

  9. Sinoatrial tissue of crucian carp heart has only negative contractile responses to autonomic agonists

    Directory of Open Access Journals (Sweden)

    Hälinen Mervi

    2010-06-01

    Full Text Available Abstract Background In the anoxia-tolerant crucian carp (Carassius carassius cardiac activity varies according to the seasons. To clarify the role of autonomic nervous control in modulation of cardiac activity, responses of atrial contraction and heart rate (HR to carbacholine (CCh and isoprenaline (Iso were determined in fish acclimatized to winter (4°C, cold-acclimated, CA and summer (18°C, warm-acclimated, WA temperatures. Results Inhibitory action of CCh was much stronger on atrial contractility than HR. CCh reduced force of atrial contraction at an order of magnitude lower concentrations (EC50 2.75-3.5·10-8 M in comparison to its depressive effect on HR (EC50 1.23-2.02·10-7 M (P -8 M and 10-7 M CCh, respectively (P + current, IK,CCh, with an EC50 value of 3-4.5·10-7 M and inhibited Ca2+ current (ICa by 28 ± 8% and 51 ± 6% at 10-7 M and 10-6 M, respectively. These currents can explain the shortening of AP. Iso did not elicit any responses in crucian carp sinoatrial preparations nor did it have any effect on atrial ICa, probably due to the saturation of the β-adrenergic cascade in the basal state. Conclusion In the crucian carp, HR and force of atrial contraction show cardio-depressive responses to the cholinergic agonist, but do not have any responses to the β-adrenergic agonist. The scope of inhibitory regulation by CCh is increased by the high basal tone of the adenylate cyclase-cAMP cascade. Higher concentrations of CCh were required to induce IK,CCh and inhibit ICa than was needed for CCh's negative inotropic effect on atrial muscle suggesting that neither IK,CCh nor ICa alone can mediate CCh's actions but they might synergistically reduce AP duration and atrial force production. Autonomic responses were similar in CA winter fish and WA summer fish indicating that cardiac sensitivity to external modulation by the autonomic nervous system is not involved in seasonal acclimatization of the crucian carp heart to cold and anoxic

  10. Oxidized CaMKII causes cardiac sinus node dysfunction in mice

    Science.gov (United States)

    Swaminathan, Paari Dominic; Purohit, Anil; Soni, Siddarth; Voigt, Niels; Singh, Madhu V.; Glukhov, Alexey V.; Gao, Zhan; He, B. Julie; Luczak, Elizabeth D.; Joiner, Mei-ling A.; Kutschke, William; Yang, Jinying; Donahue, J. Kevin; Weiss, Robert M.; Grumbach, Isabella M.; Ogawa, Masahiro; Chen, Peng-Sheng; Efimov, Igor; Dobrev, Dobromir; Mohler, Peter J.; Hund, Thomas J.; Anderson, Mark E.

    2011-01-01

    Sinus node dysfunction (SND) is a major public health problem that is associated with sudden cardiac death and requires surgical implantation of artificial pacemakers. However, little is known about the molecular and cellular mechanisms that cause SND. Most SND occurs in the setting of heart failure and hypertension, conditions that are marked by elevated circulating angiotensin II (Ang II) and increased oxidant stress. Here, we show that oxidized calmodulin kinase II (ox-CaMKII) is a biomarker for SND in patients and dogs and a disease determinant in mice. In wild-type mice, Ang II infusion caused sinoatrial nodal (SAN) cell oxidation by activating NADPH oxidase, leading to increased ox-CaMKII, SAN cell apoptosis, and SND. p47–/– mice lacking functional NADPH oxidase and mice with myocardial or SAN-targeted CaMKII inhibition were highly resistant to SAN apoptosis and SND, suggesting that ox-CaMKII–triggered SAN cell death contributed to SND. We developed a computational model of the sinoatrial node that showed that a loss of SAN cells below a critical threshold caused SND by preventing normal impulse formation and propagation. These data provide novel molecular and mechanistic information to understand SND and suggest that targeted CaMKII inhibition may be useful for preventing SND in high-risk patients. PMID:21785215

  11. Origem das artérias dos nós sinoatrial e atrioventricular em população do sul da Índia: um estudo angiográfico Origen de las arterias de los nódulos sinusal y atrioventricular en población del Sur de la India: un estudio angiográfico Origin of the sinoatrial and atrioventricular nodal arteries in South Indians: an angiographic study

    Directory of Open Access Journals (Sweden)

    Lakshmi Ramanathan

    2009-05-01

    the arterial dominance. RESULTS: The SA (sinoatrial node was supplied by the right coronary artery (RCA in 53% of the cases, by the circumflex (Cx branch of left coronary artery (LCA in 42.66%, and by both coronary arteries in 4.33% of cases. The AV (atrioventricular node was also more often supplied by the RCA (72.33% of cases than by the Cx branch of the LCA (27.66%, and surprisingly in none of the cases was this node supplied by both coronary arteries. CONCLUSION: The results of the present study may help cardiac surgeons, particularly in surgeries related to certain valvular disorders, due to the proximity of the nodal branches to the valve complex.

  12. Análise comparativa entre a vascularização ventricular e do nó sinoatrial em gatos

    Directory of Open Access Journals (Sweden)

    Caio Biasi

    2012-01-01

    Full Text Available A possível existência de interdependência na nutrição de territórios atriais e ventriculares tem sido objeto de preocupação por partes dos cardiologistas, especialmente no que tange a vascularização do nó sinoatrial e sua dependência apenas de uma artéria coronária ou de ambas e de sua relação com o predomínio destes vasos na vascularização ventricular. Assim, este estudo objetiva avaliar a relação da irrigação do nó sinoatrial e a origem e a predominância das artérias coronárias na vascularização dos ventrículos, para tanto utilizou-se 30 corações de gatos sem raça definida adultos, machos e fêmeas, sem sinais de afecção cardíaca. Os corações foram injetados pela aorta torácica com Neoprene Latex 450, corados com pigmento vermelho e dissecados posteriormente. Verificou-se que quando ocorria predomínio da vascularização ventricular do tipo esquerda (63,34% a irrigação do nó sinoatrial ficou predominantemente na dependência do ramo proximal atrial direito (78,9% ou com menor freqüência pelo ramo proximal atrial esquerdo (21,1%. Na vascularização ventricular do tipo equilibrada (33,34%, a irrigação do sinoatrial ficou na dependência mais freqüentemente do ramo proximal atrial direito (80%, ou com menor freqüência a nutrição do nó se deu pelo ramo proximal atrial esquerdo (20%. Em um caso isolado, ocorreu a vascularização ventricular do tipo direita (3,34%, a nutrição do sinoatrial, ficou na dependência exclusiva do ramo intermédio atrial direito. Estes resultados indicam que nesta espécie não existe relação entre a irrigação do nó sinoatrial e o tipo de vascularização ventricular, independentemente do sexo.

  13. Cycle length dependence of the chronotropic effects of adrenaline, acetylcholine, Ca2+ and Mg2+ in the Guinea-pig sinoatrial node

    NARCIS (Netherlands)

    Opthof, T.; de Jonge, B.; Schade, B.; Jongsma, H. J.; Bouman, L. N.

    1984-01-01

    Ca (1.1-5.5 mM) has a positive chronotropic action on isolated right atria of the guinea-pig. The magnitude of the response depends on the cycle length. Magnitude and cycle length dependence of the Ca response are independent of beta-blockade by propranolol. Mg (0.6-6.0 mM) has a negative

  14. Variação nos tipos de irrigação do nodo sinoatrial em cães de diferentes raças

    Directory of Open Access Journals (Sweden)

    Phelipe O. Favaron

    Full Text Available RESUMO: Considerando a heterogeneidade anatômica e eletrofisiológica do nodo sinoatrial para a geração e propagação do potencial de ação, bem como as particularidades relacionadas a origem da sua irrigação sanguínea, este trabalho teve como objetivo analisar o comportamento das artérias envolvidas na irrigação do nodo sinoatrial em cães realizando uma análise descritiva e comparativa entre diferentes raças estudadas, detalhando a origem, o percurso e a ramescência dos vasos, assim como a eventual ocorrência de anastomoses. Ao todo analisamos resultados obtidos em 240 corações, os quais foram fixados em solução de formalina 10% e submetidos a diafanização de Spalteholz. A irrigação deste ocorre mediante colaterais oriundos do ramo circunflexo direito ou ramo circunflexo esquerdo, mostrando particularidades diferentes para cada raça. Assim, predominantemente, nas raças ora estudadas a irrigação arterial do nodo sinoatrial depende exclusivamente (63,6%, ou de anastomoses de colaterais da artéria coronária direita, havendo também participação dos ramo proximal atrial direito e intermédio atrial direito. Menos frequentemente (15,4% o suprimento sanguíneo ocorre exclusivamente por conta do ramo proximal atrial esquerdo, oriundo do ramo circunflexo da artéria coronária esquerda. Os dados aqui apresentados sobre a origem da irrigação sanguínea do nodo sinoatrial e a ramescência dos vasos envolvidos nesta tarefa representam conhecimento fundamental para o desenvolvimento da clínica-cirúrgica em cães, da patologia e trabalhos de natureza experimental.

  15. Spontaneous, local diastolic subsarcolemmal calcium releases in single, isolated guinea-pig sinoatrial nodal cells.

    Science.gov (United States)

    Sirenko, Syevda G; Yang, Dongmei; Maltseva, Larissa A; Kim, Mary S; Lakatta, Edward G; Maltsev, Victor A

    2017-01-01

    Uptake and release calcium from the sarcoplasmic reticulum (SR) (dubbed "calcium clock"), in the form of spontaneous, rhythmic, local diastolic calcium releases (LCRs), together with voltage-sensitive ion channels (membrane clock) form a coupled system that regulates the action potential (AP) firing rate. LCRs activate Sodium/Calcium exchanger (NCX) that accelerates diastolic depolarization and thus participating in regulation of the time at which the next AP will occur. Previous studies in rabbit SA node cells (SANC) demonstrated that the basal AP cycle length (APCL) is tightly coupled to the basal LCR period (time from the prior AP-induced Ca2+ transient to the diastolic LCR occurrence), and that this coupling is further modulated by autonomic receptor stimulation. Although spontaneous LCRs during diastolic depolarization have been reported in SANC of various species (rabbit, cat, mouse, toad), prior studies have failed to detect LCRs in spontaneously beating SANC of guinea-pig, a species that has been traditionally used in studies of cardiac pacemaker cell function. We performed a detailed investigation of whether guinea-pig SANC generate LCRs and whether they play a similar key role in regulation of the AP firing rate. We used two different approaches, 2D high-speed camera and classical line-scan confocal imaging. Positioning the scan-line beneath sarcolemma, parallel to the long axis of the cell, we found that rhythmically beating guinea-pig SANC do, indeed, generate spontaneous, diastolic LCRs beneath the surface membrane. The average key LCR characteristics measured in confocal images in guinea-pig SANC were comparable to rabbit SANC, both in the basal state and in the presence of β-adrenergic receptor stimulation. Moreover, the relationship between the LCR period and APCL was subtended by the same linear function. Thus, LCRs in guinea-pig SANC contribute to the diastolic depolarization and APCL regulation. Our findings indicate that coupled-clock system

  16. Modular sensor network node

    Science.gov (United States)

    Davis, Jesse Harper Zehring [Berkeley, CA; Stark, Jr., Douglas Paul; Kershaw, Christopher Patrick [Hayward, CA; Kyker, Ronald Dean [Livermore, CA

    2008-06-10

    A distributed wireless sensor network node is disclosed. The wireless sensor network node includes a plurality of sensor modules coupled to a system bus and configured to sense a parameter. The parameter may be an object, an event or any other parameter. The node collects data representative of the parameter. The node also includes a communication module coupled to the system bus and configured to allow the node to communicate with other nodes. The node also includes a processing module coupled to the system bus and adapted to receive the data from the sensor module and operable to analyze the data. The node also includes a power module connected to the system bus and operable to generate a regulated voltage.

  17. Related Drupal Nodes Block

    NARCIS (Netherlands)

    Van der Vegt, Wim

    2010-01-01

    Related Drupal Nodes Block This module exposes a block that uses Latent Semantic Analysis (Lsa) internally to suggest three nodes that are relevant to the node a user is viewing. This module performs three tasks. 1) It periodically indexes a Drupal site and generates a Lsa Term Document Matrix.

  18. Live and Dead Nodes

    DEFF Research Database (Denmark)

    Jørgensen, Sune Lehman; Jackson, A. D.

    2005-01-01

    In this paper, we explore the consequences of a distinction between `live' and `dead' network nodes; `live' nodes are able to acquire new links whereas `dead' nodes are static. We develop an analytically soluble growing network model incorporating this distinction and show that it can provide...

  19. [Late arrhythmias in the operated interatrial communication. Analysis of sinus node function and the conduction pathways by His bundle electrocardiography].

    Science.gov (United States)

    Ramírez, A; Gil, M; Martínez Ríos, M A; Cárdenas, M; Pliego, J; Zamora, C; Mata, L A

    1982-01-01

    Four hundred patients with atrial septal defect treated surgically were reviewed. Thirty five (8.7%) developed arrhytmias post-surgery which persisted for over a year. Sinus bradycardia was found in 10 patients, nodal rhythm in 21, and atrial fibrilation and flutter in 4 patients. Thirty five per cent of the patients with late arrhythmias developed related symptomatology. In 14 patients the function of the sinus node was studied with electrical stimulation of the atrium and with His registry. The interatrial conduction time, AV node and His Purkinje were analized employing various stimulation frequencies. All the cases studied had normal intra-atrial conduction; the response of the atrio-ventricular node to increasing frequencies was normal, an the intraventricular conduction remained constant. In 8 patients (52%), alterations of the sinus node were found; these consisted of prolonged post-stimulation pauses, Wenckebach's type sinoatrial block and suppression of sinus automatism employing vagal procedures or through electrical stimulation. A patient with severe bradycardia detected by dynamic electrocardiography had to be treated with a permanent pacemaker. We confirm that these arrhytmias are not produced by lesions of the internodal tracts, and that an alteration of the sinus node is frequent without a concomitant lesion of the intraventricular pathway. The lesion to the nutrient artery could be due to trauma and/or surgically induced. The response to anticholinergic drugs was good. Prolonged observation of these patients could increase the morbility of these arrythmias and raise doubts of the surgical indications in cases with moderate hemodynamic repercussion.

  20. Protocol for multiple node network

    Science.gov (United States)

    Kirkham, Harold (Inventor)

    1995-01-01

    The invention is a multiple interconnected network of intelligent message-repeating remote nodes which employs an antibody recognition message termination process performed by all remote nodes and a remote node polling process performed by other nodes which are master units controlling remote nodes in respective zones of the network assigned to respective master nodes. Each remote node repeats only those messages originated in the local zone, to provide isolation among the master nodes.

  1. Irrigação do nó sinoatrial em suínos da raça Piètrain

    Directory of Open Access Journals (Sweden)

    Renato Souto Severino

    2000-01-01

    Full Text Available Estudou-se, em 30 (trinta corações de suínos da raça Piètrain, adultos e de ambos os sexos, a irrigação do nó sinoatrial, visando conhecer a origem, trajeto e distribuição dos vasos responsáveis pela nutrição deste tecido, bem como eventuais anastomoses que pudessem ocorrer entre estes colaterais. Para tanto, os corações tiveram seus sistemas coronarianos canulados e injetados com uma solução corada de Neoprene látex 450, fixados em solução aquosa de formol a 10% e dissecados os ramos atriais das artérias coronárias esquerda e direita. Constatou-se que em 27 (90% ± 5,47 corações o tecido nodal é irrigado por colaterais provenientes da A. coronária direita, mais precisamente pelo ramo atrial proximal direito, isoladamente em 18 (60% ± 8,94 órgãos ou associado: ao ramo atrial intermédio direito em 7 (23,33% ± 7,72 ou ao ramo atrial distal direito em 2 (6,66% ± 4,55. Em 3 (10% ± 5,47 órgãos, o nó sinoatrial é vascularizado por colaterais provenientes das Aa. coronárias direita e esquerda, sempre por meio do ramo atrial proximal direito, associado ao ramo atrial proximal esquerdo em 2 (6,66% ± 4,55 ou aos ramos atriais intermédio direito e proximal esquerdo em 1 (3,33% ± 3,27 órgão. Evidenciaram-se, ainda, anastomoses travadas entre os diferentes vasos que participam da irrigação do nó sinoatrial em suínos da raça Piètrain.

  2. Deploying Node.js

    CERN Document Server

    Pasquali, Sandro

    2015-01-01

    If you are an intermediate or advanced developer deploying your Node.js applications, then this book is for you. If you have already built a Node application or module and want to take your knowledge to the next level, this book will help you find your way.

  3. Miracle Flights

    Science.gov (United States)

    ... a Flight Get Involved Events Shop Miles Contact Miracle Flights Blog Giving Tuesday 800-359-1711 Thousands of children have been saved, but we still have miles to go. Request a Flight Click Here to Donate - Your ...

  4. Intelligent Mission Controller Node

    National Research Council Canada - National Science Library

    Perme, David

    2002-01-01

    The goal of the Intelligent Mission Controller Node (IMCN) project was to improve the process of translating mission taskings between real-world Command, Control, Communications, Computers, and Intelligence (C41...

  5. Lymph node culture

    Science.gov (United States)

    Culture - lymph node ... or viruses grow. This process is called a culture. Sometimes, special stains are also used to identify specific cells or microorganisms before culture results are available. If needle aspiration does not ...

  6. Análise comparativa entre a vascularização arterial ventricular e do nó sinoatrial em corações de cães

    Directory of Open Access Journals (Sweden)

    Caio Biasi

    2013-01-01

    Full Text Available Utilizamos nesta pesquisa 40 corações de cães adultos, machos e fêmeas, de idades variadas, que não portavam nenhuma afecção cardíaca. Os corações tiveram as artérias coronárias injetadas, separadamente, com Neoprene Látex 450, corado com pigmento vermelho, e posteriormente dissecados. Em todas estas preparações verificamos que na vascularização dos ventrículos predominava a artéria coronária esquerda que fornecia os ramos interventriculares paraconal e subsinuoso. Já, a região ocupada pelo nó sinoatrial ficava mais frequentemente (17 vezes, 42,5% na dependência do ramo proximal atrial esquerdo ou de colateral deste vaso, oriundo do ramo circunflexo esquerdo, ou deste vaso associado ao ramo distal atrial direito (8 vezes, 20%, procedente do ramo circunflexo direito. Com menor frequência (14 vezes, 30%, a área tomada pelo nó sinoatrial, encontramos apenas colaterais do ramo circunflexo direito, mais exatamente somente o ramo distal atrial direito (10 vezes, 25%, apenas o ramo proximal atrial direito (3 vezes, 7,5% ou ainda exclusivamente o ramo intermédio atrial direito (1 vez, 2,5%. Em um único caso (1 vez, 2,5% no território do nó sinoatrial observamos apenas colateral do ramo circunflexo esquerdo, isto é o ramo distal atrial esquerdo. A análise destes resultados permite concluir, que nesta espécie não existe qualquer tipo de relação entre o tipo de vascularização dos ventrículos e a irrigação do nó sinoatrial. Sendo assim, considerar os ramos ventriculares isoladamente não é suficiente para um entendimento clínico-cirúrgico aplicado, uma vez que os ramos atriais apresentam uma importante contribuição para a vascularização do nó sinoatrial.

  7. Instant node package module

    CERN Document Server

    Ali, Juzer

    2013-01-01

    Get to grips with a new technology, understand what it is and what it can do for you, and then get to work with the most important features and tasks. A practical exploration of the lifecycle of creating node modules as well as learning all of the top features that npm has to offer.Intended for readers who want to create their first node.js modules. The programming paradigm of JavaScript is not covered so a foundation in these concepts would be beneficial.

  8. Involved Node Radiation Therapy

    DEFF Research Database (Denmark)

    Maraldo, Maja V; Aznar, Marianne C; Vogelius, Ivan R

    2012-01-01

    PURPOSE: The involved node radiation therapy (INRT) strategy was introduced for patients with Hodgkin lymphoma (HL) to reduce the risk of late effects. With INRT, only the originally involved lymph nodes are irradiated. We present treatment outcome in a retrospective analysis using this strategy...... to 36 Gy). Patients attended regular follow-up visits until 5 years after therapy. RESULTS: The 4-year freedom from disease progression was 96.4% (95% confidence interval: 92.4%-100.4%), median follow-up of 50 months (range: 4-71 months). Three relapses occurred: 2 within the previous radiation field......, and 1 in a previously uninvolved region. The 4-year overall survival was 94% (95% confidence interval: 88.8%-99.1%), median follow-up of 58 months (range: 4-91 months). Early radiation therapy toxicity was limited to grade 1 (23.4%) and grade 2 (13.8%). During follow-up, 8 patients died, none from HL, 7...

  9. One node driving synchronisation

    Science.gov (United States)

    Wang, Chengwei; Grebogi, Celso; Baptista, Murilo S.

    2015-12-01

    Abrupt changes of behaviour in complex networks can be triggered by a single node. This work describes the dynamical fundamentals of how the behaviour of one node affects the whole network formed by coupled phase-oscillators with heterogeneous coupling strengths. The synchronisation of phase-oscillators is independent of the distribution of the natural frequencies, weakly depends on the network size, but highly depends on only one key oscillator whose ratio between its natural frequency in a rotating frame and its coupling strength is maximum. This result is based on a novel method to calculate the critical coupling strength with which the phase-oscillators emerge into frequency synchronisation. In addition, we put forward an analytical method to approximately calculate the phase-angles for the synchronous oscillators.

  10. Node web development

    CERN Document Server

    Herron, David

    2013-01-01

    Presented in a simple, step-by-step format, this book is an introduction to web development with Node.This book is for anybody looking for an alternative to the ""P"" languages (Perl, PHP, Python), or anyone looking for a new paradigm of server-side application development.The reader should have at least a rudimentary understanding of JavaScript and web application development.

  11. Status of lymph node staging

    NARCIS (Netherlands)

    Nieweg, O. E.; Estourgie, S. H.; Deurloo, E. E.; Rutgers, E. J. Th; Kroon, B. B. R.

    2002-01-01

    Sentinel node biopsy has the potential to provide more accurate staging information than axillary node dissection. Given the considerable morbidity of axillary node dissection this less invasive approach is attractive. However, there are a number of issues to be resolved before the best technique of

  12. Effect of interconnection between cervical vagus trunk, epicardial fat pad on sinus node function, and atrial fibrillation.

    Science.gov (United States)

    Zhou, Qina; Zhang, Ling; Wang, Kun; Xu, Xiaoxia; Ji, Meng; Zhang, Feng; Wang, Hongli; Hou, Yuemei

    2014-03-01

    The epicardial fat pad (FP) integrates the autonomic innervation between the extrinsic and intrinsic cardiac autonomic nervous system and affects atrial electrophysiology and pathophysiology. Eighteen dogs were divided into two groups: sequential ablation of sinoatrial node FP (SAN-FP) and atrioventricular node FP (AVN-FP). Sinus rate (SR), atrial fibrillation (AF) inducibility, and effective refractory period (ERP) changes during electrical stimulation of the vagus trunk were detected before and after ablation. In the SAN-FP group, the SR slowing, increasing AF inducibility, and ERP shortening that induced by vagus trunk stimulation were significantly attenuated by isolated SAN-FP ablation, compared with the same group prior to ablation (all P AVN-FP ablation following SAN-FP ablation almost cannot produce further attenuation during vagus trunk stimulation, compared with isolated SAN-FP ablation (P > 0.05). In the AVN-FP group, SR slowing, increasing AF inducibility, and ERP shortening that induced by vagus trunk stimulation were completely eliminated by isolated AVN-FP ablation, compared with the same group prior to ablation (all P AVN-FP ablation produced no further attenuation, compared with isolated AVN-FP ablation (P > 0.05). A neural pathway from the cervical vagus trunk to the sinus node and atrium runs through the SAN-FP, but eventually converges at the AVN-FP and also suggested that the AVN-FP serves as an "integration center" for the SAN-FP to modulate sinus node function. The AVN-FP may play a more critical role in the initiation and maintenance of AF. ©2013 First Affilated Hospital of Xingiang Medical University Pacing and Clinical Electrophysiology ©2013 Wiley Periodicals, Inc.

  13. Inhibition of sarcoplasmic reticulum Ca(2+)-ATPase decreases atrioventricular node-paced heart rate in rabbits.

    Science.gov (United States)

    Cheng, Hongwei; Smith, Godfrey L; Orchard, Clive H; Hancox, Jules C; Burton, Francis L

    2012-10-01

    Recent data indicate that Ca(2+) cycling in isolated atrioventricular node (AVN) cells contributes to setting spontaneous rate. The aim of the present study was to extend this observation to the intact AVN in situ, by evaluating the effects of inhibiting sarcoplasmic reticulum Ca(2+) uptake with cyclopiazonic acid (CPA) on intact AVN spontaneous activity and its response to isoprenaline. A model of the AVN-paced heart was produced to investigate intact AVN automaticity, by surgical ablation of the sino-atrial node (SAN) in the rabbit Langendorff-perfused heart. Electrograms were recorded from a site close to the AVN (triangle of Koch), an atrial site above the AVN, the left atrium and right ventricle, enabling AVN pacing of the preparation to be confirmed. Before SAN ablation, the heart rate was 166.8 ± 5.4 beats min(-1). Ablation of the SAN was clearly indicated by a sudden and significant decrease of heart rate to 108.6 ± 9.6 beats min(-1) (P AVN rate to 187.8 ± 12.0 beats min(-1) after 1 min of application (P AVN rate to 81.6 ± 4.8 (n = 9) and 77.4 ± 6.0 beats min(-1) (n = 7), respectively [P AVN rate increase in response to isoprenaline from 78.8 ± 10.0 to 46.8 ± 6.8 and 26.7 ± 5.3%, respectively (P AVN rate and its response to isoprenaline indicate that Ca(2+) cycling is important to the intact AVN spontaneous activity and its acceleration during sympathetic stimulation.

  14. Flight Planning

    Science.gov (United States)

    1991-01-01

    Seagull Technology, Inc., Sunnyvale, CA, produced a computer program under a Langley Research Center Small Business Innovation Research (SBIR) grant called STAFPLAN (Seagull Technology Advanced Flight Plan) that plans optimal trajectory routes for small to medium sized airlines to minimize direct operating costs while complying with various airline operating constraints. STAFPLAN incorporates four input databases, weather, route data, aircraft performance, and flight-specific information (times, payload, crew, fuel cost) to provide the correct amount of fuel optimal cruise altitude, climb and descent points, optimal cruise speed, and flight path.

  15. Sentinel nodes outside lymph node basins in patients with melanoma

    NARCIS (Netherlands)

    Roozendaal, GK; de Vries, JDH; van Poll, D; Jansen, L; Nieweg, OE; Kroon, BBR; Schraffordt Koops, H.

    Background: Lymphoscintigraphy occasionally reveals hot spots outside lymph node basins in patients with melanoma. The aim of this study was to evaluate such abnormally located hot spots. Methods: Sentinel node biopsy was studied prospectively in 379 patients with clinically localized cutaneous

  16. Small functional If current in sinoatrial pacemaker cells of the brown trout (Salmo trutta fario) heart despite strong expression of HCN channel transcripts.

    Science.gov (United States)

    Hassinen, Minna; Haverinen, Jaakko; Vornanen, Matti

    2017-12-01

    Funny current ( I f ), formed by hyperpolarization-activated cyclic nucleotide-gated channels (HCN channels), is supposed to be crucial for the membrane clock regulating the cardiac pacemaker mechanism. We examined the presence and activity of HCN channels in the brown trout ( Salmo trutta fario ) sinoatrial (SA) pacemaker cells and their putative role in heart rate ( f H ) regulation. Six HCN transcripts (HCN1, HCN2a, HCN2ba, HCN2bb, HCN3, and HCN4) were expressed in the brown trout heart. The total HCN transcript abundance was 4.0 and 4.9 times higher in SA pacemaker tissue than in atrium and ventricle, respectively. In the SA pacemaker, HCN3 and HCN4 were the main isoforms representing 35.8 ± 2.7 and 25.0 ± 1.5%, respectively, of the total HCN transcripts. Only a small I f with a mean current density of -1.2 ± 0.37 pA/pF at -140 mV was found in 4 pacemaker cells out of 16 spontaneously beating cells examined, despite the optimization of recording conditions for I f activity. I f was not found in any of the 24 atrial myocytes and 21 ventricular myocytes examined. HCN4 coexpressed with the MinK-related peptide 1 (MiRP1) β-subunit in CHO cells generated large I f currents. In contrast, HCN3 (+MiRP1) failed to produce I f in the same expression system. Cs + (2 mM), which blocked 84 ± 12% of the native I f , reversibly reduced f H 19.2 ± 3.6% of the excised multicellular pacemaker tissue from 53 ± 5 to 44 ± 5 beats/min ( P brown trout heart is largely independent on I f . Copyright © 2017 the American Physiological Society.

  17. NRC/UBC Node

    Energy Technology Data Exchange (ETDEWEB)

    Ellis-Perry, B. [Univ. of British Columbia, Vancouver, British Columbia (Canada); Yogendran, Y. [NRC Inst. for Fuel Cell Innovation, Vancouver, British Columbia (Canada)

    2004-07-01

    'Full text:' In the search for cleaner, more sustainable energy sources, many of the most promising breakthroughs have been in hydrogen technology. However, this promise will remain unfulfilled without public interest and enthusiasm, and without the infrastructure to support the technology. In order to get there, we have to test, perfect, and demonstrate technology that is safe and affordable, and we must do so in practical, familiar settings. Ideally, such settings should be easily accessible to the engineers, planners, and architects of tomorrow while providing a showcase for hydrogen technology that will attract the general public. This place is the NRC/UBC Hydrogen Node. The UBC campus in Point Grey is home to leading edge, internationally recognized researchers in a range of disciplines, both within the University and at the NRC Institute for Fuel Cell Innovation. On average, 40,000 students, faculty, and staff use the campus every day; UBC graduates go on to leadership positions in communities around the globe. Its spectacular setting makes UBC a popular destination for thousands of visitors from around the world. In 2006 UBC will host the World Urban Forum, and in 2010 it will be one of the sites for the Vancouver-Whistler Olympic Games. UBC and its South Campus neighbourhoods are developing as a model sustainable community, offering an excellent opportunity to develop and showcase hydrogen infrastructure and technology in a real-life, attractive setting that will be seen by thousands of people around the world. UBC's facilities, location, and Trek 2010 commitment to excellence in learning, research, and sustainability make it an ideal location for such a project. The H2 Village at UBC will be an integrated hydrogen demonstration project, linked to the hydrogen highway. This project is bringing together leading companies, researchers, and government agencies committed to making the refinement and early adoption of safe hydrogen technology a

  18. NRC/UBC Node

    International Nuclear Information System (INIS)

    Ellis-Perry, B.; Yogendran, Y.

    2004-01-01

    'Full text:' In the search for cleaner, more sustainable energy sources, many of the most promising breakthroughs have been in hydrogen technology. However, this promise will remain unfulfilled without public interest and enthusiasm, and without the infrastructure to support the technology. In order to get there, we have to test, perfect, and demonstrate technology that is safe and affordable, and we must do so in practical, familiar settings. Ideally, such settings should be easily accessible to the engineers, planners, and architects of tomorrow while providing a showcase for hydrogen technology that will attract the general public. This place is the NRC/UBC Hydrogen Node. The UBC campus in Point Grey is home to leading edge, internationally recognized researchers in a range of disciplines, both within the University and at the NRC Institute for Fuel Cell Innovation. On average, 40,000 students, faculty, and staff use the campus every day; UBC graduates go on to leadership positions in communities around the globe. Its spectacular setting makes UBC a popular destination for thousands of visitors from around the world. In 2006 UBC will host the World Urban Forum, and in 2010 it will be one of the sites for the Vancouver-Whistler Olympic Games. UBC and its South Campus neighbourhoods are developing as a model sustainable community, offering an excellent opportunity to develop and showcase hydrogen infrastructure and technology in a real-life, attractive setting that will be seen by thousands of people around the world. UBC's facilities, location, and Trek 2010 commitment to excellence in learning, research, and sustainability make it an ideal location for such a project. The H2 Village at UBC will be an integrated hydrogen demonstration project, linked to the hydrogen highway. This project is bringing together leading companies, researchers, and government agencies committed to making the refinement and early adoption of safe hydrogen technology a reality

  19. Electrophysiological heterogeneity of pacemaker cells in the rabbit intercaval region, including the SA node: insights from recording multiple ion currents in each cell.

    Science.gov (United States)

    Monfredi, Oliver; Tsutsui, Kenta; Ziman, Bruce; Stern, Michael D; Lakatta, Edward G; Maltsev, Victor A

    2018-03-01

    Cardiac pacemaker cells, including cells of the sinoatrial node, are heterogeneous in size, morphology, and electrophysiological characteristics. The exact extent to which these cells differ electrophysiologically is unclear yet is critical to understanding their functioning. We examined major ionic currents in individual intercaval pacemaker cells (IPCs) sampled from the paracristal, intercaval region (including the sinoatrial node) that were spontaneously beating after enzymatic isolation from rabbit hearts. The beating rate was measured at baseline and after inhibition of the Ca 2+ pump with cyclopiazonic acid. Thereafter, in each cell, we consecutively measured the density of funny current ( I f ), delayed rectifier K + current ( I K ) (a surrogate of repolarization capacity), and L-type Ca 2+ current ( I Ca,L ) using whole cell patch clamp . The ionic current densities varied to a greater extent than previously appreciated, with some IPCs demonstrating very small or zero I f . The density of none of the currents was correlated with cell size, while I Ca,L and I f densities were related to baseline beating rates. I f density was correlated with I K density but not with that of I Ca,L . Inhibition of Ca 2+ cycling had a greater beating rate slowing effect in IPCs with lower I f densities. Our numerical model simulation indicated that 1) IPCs with small (or zero) I f or small I Ca,L can operate via a major contribution of Ca 2+ clock, 2) I f -Ca 2+ -clock interplay could be important for robust pacemaking function, and 3) coupled I f - I K function could regulate maximum diastolic potential. Thus, we have demonstrated marked electrophysiological heterogeneity of IPCs. This heterogeneity is manifested in basal beating rate and response to interference of Ca 2+ cycling, which is linked to I f . NEW & NOTEWORTHY In the present study, a hitherto unrecognized range of heterogeneity of ion currents in pacemaker cells from the intercaval region is demonstrated

  20. Acute desensitization of acetylcholine and endothelin-1 activated inward rectifier K+ current in myocytes from the cardiac atrioventricular node.

    Science.gov (United States)

    Choisy, Stéphanie C M; James, Andrew F; Hancox, Jules C

    2012-07-06

    The atrioventricular node (AVN) is a vital component of the pacemaker-conduction system of the heart, co-ordinating conduction of electrical excitation from cardiac atria to ventricles and acting as a secondary pacemaker. The electrical behaviour of the AVN is modulated by vagal activity via activation of muscarinic potassium current, IKACh. However, it is not yet known if this response exhibits 'fade' or desensitization in the AVN, as established for the heart's primary pacemaker--the sinoatrial node. In this study, acute activation of IKACh in rabbit single AVN cells was investigated using whole-cell patch clamp at 37 °C. 0.1-1 μM acetylcholine (ACh) rapidly activated a robust IKACh in AVN myocytes during a descending voltage-ramp protocol. This response was inhibited by tertiapin-Q (TQ; 300 nM) and by the M2 muscarinic ACh receptor antagonist AFDX-116 (1 μM). During sustained ACh exposure the elicited IKACh exhibited bi-exponential fade (τf of 2.0 s and τs 76.9 s at -120 mV; 1 μM ACh). 10 nM ET-1 elicited a current similar to IKACh, which faded with a mono-exponential time-course (τ of 52.6 s at -120 mV). When ET-1 was applied following ACh, the ET-1 activated response was greatly attenuated, demonstrating that ACh could desensitize the response to ET-1. For neither ACh nor ET-1 was the rate of current fade dependent upon the initial response magnitude, which is inconsistent with K+ flux mediated changes in electrochemical driving force as the underlying mechanism. Collectively, these findings demonstrate that TQ sensitive inwardly rectifying K+ current in cardiac AVN cells, elicited by M2 muscarinic receptor or ET-1 receptor activation, exhibits fade due to rapid desensitization. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. Intraoperative Sentinel Lymph Node Evaluation

    DEFF Research Database (Denmark)

    Shaw, Richard; Christensen, Anders; Java, Kapil

    2016-01-01

    BACKGROUND: Intraoperative analysis of sentinel lymph nodes would enhance the care of early-stage oral squamous cell carcinoma (OSCC). We determined the frequency and extent of cytokeratin 19 (CK19) expression in OSCC primary tumours and surrounding tissues to explore the feasibility of a "clinic......-ready" intraoperative diagnostic test (one step nucleic acid amplification-OSNA, sysmex). METHODS: Two cohorts were assembled: cohort 1, OSCC with stage and site that closely match cases suitable for sentinel lymph node biopsy (SLNB); cohort 2, HNSCC with sufficient fresh tumour tissue available for the OSNA assay (>50......% of tumours. Discordance between different techniques indicated that OSNA was more sensitive than qRT-PCR or RNA-ISH, which in turn were more sensitive than IHC. OSNA results showed CK19 expression in 80% of primary cases, so if used for diagnosis of lymph node metastasis would lead to a false-negative result...

  2. Methodology of sentinel node detection

    International Nuclear Information System (INIS)

    Maublant, J.

    2000-01-01

    The isotopic localisation of the sentinel node, i.e., the first functional lymph node in a tumor basin, is probably the fastest growing field ever experienced in nuclear medicine. Although based on the simple concept of the lymphatic migration of Tc-labeled colloids, the choice of the optimal technique remains controversial. We review and discuss the role of the colloids, of the site of injection, of the injected volume, of early imaging and of the colorimetric approach. Initially applied to melanoma and breast cancer, the sentinel node detection is now tested in other types of cancer such as lung, colon and prostate. It could become one of the leading tools in minimally invasive surgical oncology. The nuclear medicine physician has to remain aware of the rapid evolutions in this field in order to be able to answer to a rapidly growing demand. (author)

  3. Allocating resources between network nodes for providing a network node function

    NARCIS (Netherlands)

    Strijkers, R.J.; Meulenhoff, P.J.

    2014-01-01

    The invention provides a method wherein a first network node advertises available resources that a second network node may use to offload network node functions transparently to the first network node. Examples of the first network node are a client device (e.g. PC, notebook, tablet, smart phone), a

  4. Does the atrioventricular node conduct?

    NARCIS (Netherlands)

    Meijler, F.L.; Fisch, C.

    1989-01-01

    It is difficult to be certain wh en the term "conduction" was first applied to the transfer of atrial activation to the ventricles .' In 1894, Engelmann used the word "Leitung", which can be translated as "connection" or as "conduction" .2 In 1906, Tawara described the atrioventricular node,

  5. Node.js by example

    CERN Document Server

    Tsonev, Krasimir

    2015-01-01

    If you are a JavaScript developer with no experience with Node.js or server-side web development, this book is for you. It will lead you through creating a fairly complex social network. You will learn how to work with a database and create real-time communication channels.

  6. Smart Home Wireless Sensor Nodes

    DEFF Research Database (Denmark)

    Lynggaard, Per

    . This paper introduces an approach that considerably lowers the wireless sensor node power consumption and the amount of transmitted sensor events. It uses smart objects that include artificial intelligence to efficiently process the sensor event on location and thereby saves the costly wireless...

  7. Critical nodes in signalling pathways

    DEFF Research Database (Denmark)

    Taniguchi, Cullen M; Emanuelli, Brice; Kahn, C Ronald

    2006-01-01

    Physiologically important cell-signalling networks are complex, and contain several points of regulation, signal divergence and crosstalk with other signalling cascades. Here, we use the concept of 'critical nodes' to define the important junctions in these pathways and illustrate their unique role...... using insulin signalling as a model system....

  8. Controlling data transfers from an origin compute node to a target compute node

    Science.gov (United States)

    Archer, Charles J [Rochester, MN; Blocksome, Michael A [Rochester, MN; Ratterman, Joseph D [Rochester, MN; Smith, Brian E [Rochester, MN

    2011-06-21

    Methods, apparatus, and products are disclosed for controlling data transfers from an origin compute node to a target compute node that include: receiving, by an application messaging module on the target compute node, an indication of a data transfer from an origin compute node to the target compute node; and administering, by the application messaging module on the target compute node, the data transfer using one or more messaging primitives of a system messaging module in dependence upon the indication.

  9. Allocating resources between network nodes for providing a network node function

    OpenAIRE

    Strijkers, R.J.; Meulenhoff, P.J.

    2014-01-01

    The invention provides a method wherein a first network node advertises available resources that a second network node may use to offload network node functions transparently to the first network node. Examples of the first network node are a client device (e.g. PC, notebook, tablet, smart phone), a server (e.g. application server, a proxy server, cloud location, router). Examples of the second network node are an application server, a cloud location or a router. The available resources may b...

  10. Secure message authentication system for node to node network

    Science.gov (United States)

    Sindhu, R.; Vanitha, M. M.; Norman, J.

    2017-10-01

    The Message verification remains some of the best actual methods for prevent the illegal and dis honored communication after presence progressed to WSNs (Wireless Sensor Networks). Intend for this purpose, several message verification systems must stand established, created on both symmetric key cryptography otherwise public key cryptosystems. Best of them will have some limits for great computational then statement above in count of deficiency of climb ability then flexibility in node settlement occurrence. In a polynomial based system was newly presented for these problems. Though, this system then situations delay will must the dimness of integral limitation firm in the point of polynomial: once the amount of message transferred remains the greater than the limitation then the opponent will completely improve the polynomial approaches. This paper suggests using ECC (Elliptic Curve Cryptography). Though using the node verification the technique in this paper permits some nodes to transfer a limitless amount of messages lacking misery in the limit problem. This system will have the message cause secrecy. Equally theoretic study then model effects show our planned system will be effective than the polynomial based method in positions of calculation then statement above in privacy points though message basis privacy.

  11. Codimension n saddle-nodes

    International Nuclear Information System (INIS)

    Gheiner, Jaques

    2014-01-01

    We consider the generic unfolding of a diffeomorphism on a compact C ∞ manifold that is Morse–Smale except for one non-hyperbolic periodic orbit being a codimension n saddle-node (one eigenvalue is 1, the other eigenvalues have norm different from 1). Local and global bifurcations are described. We characterize structural stability of the unfolding, depending on the codimension. A universal model of the unfolding is given when there is stability. Dynamical behaviour is analysed in other cases. (paper)

  12. Sentinel node biopsy in penile cancer

    DEFF Research Database (Denmark)

    Jakobsen, J. K.; Krarup, K. P.; Sommer, P.

    2015-01-01

    INTRODUCTION & OBJECTIVES: Nodal involvement is a strong prognosticator in penile cancer and lymph node staging is crucial. Sentinel node biopsy (SNB) has proven a useful staging tool with few complications, but evidence rely mostly on single institution publications with a short follow-up. In th......INTRODUCTION & OBJECTIVES: Nodal involvement is a strong prognosticator in penile cancer and lymph node staging is crucial. Sentinel node biopsy (SNB) has proven a useful staging tool with few complications, but evidence rely mostly on single institution publications with a short follow...... died from complications. CONCLUSIONS: To our knowledge, this is the first complete national study on sentinel node biopsy. Penile cancer sentinel node biopsy with a close follow-up is a reliable lymph node staging and has few complications in a national multicentre setting. Inguinal lymph node...

  13. Axillary Lymph Nodes and Breast Cancer

    Science.gov (United States)

    ... white blood cells that help fight illness. If breast cancer spreads, the lymph nodes in the underarm (called ... if they contain cancer cells. This helps determine breast cancer stage and guide treatment. Sentinel node biopsy and ...

  14. Sentinel Node in Oral Cancer

    DEFF Research Database (Denmark)

    Tartaglione, Girolamo; Stoeckli, Sandro J; de Bree, Remco

    2016-01-01

    /static scan and/or SPECT/CT. RESULTS: Lymphoscintigraphy identified 723 lymphatic basins. 1398 sentinel lymph nodes (SNs) were biopsied (3.2 SN per patient; range, 1-10). Dynamic scan allowed the differentiation of sentinel nodes from second tier lymph nodes. SPECT/CT allowed more accurate anatomical......PURPOSE: Nuclear imaging plays a crucial role in lymphatic mapping of oral cancer. This evaluation represents a subanalysis of the original multicenter SENT trial data set, involving 434 patients with T1-T2, N0, and M0 oral squamous cell carcinoma. The impact of acquisition techniques, tracer...... localization and estimated SN depth more efficiently. After pathological examination, 9.9% of the SN excised (138 of 1398 SNs) showed metastases. The first neck level (NL) containing SN+ was NL I in 28.6%, NL IIa in 44.8%, NL IIb in 2.8%, NL III in 17.1%, and NL IV in 6.7% of positive patients. Approximately...

  15. Cytosolic calcium ions exert a major influence on the firing rate and maintenance of pacemaker activity in guinea-pig sinus node.

    Directory of Open Access Journals (Sweden)

    Rebecca Anne Capel

    2015-02-01

    Full Text Available The sino-atrial node (SAN provides the electrical stimulus to initiate every heart beat. Cellular processes underlying this activity have been debated extensively, especially with regards to the role of intracellular calcium. We have used whole-cell application of 1,2-bis(o-aminophenoxyethane-N,N,N',N'-tetraacetic acid (BAPTA, a rapid calcium chelator, to guinea pig isolated SAN myocytes to assess the effect of rapid reduction of intracellular calcium on SAN cell electrical activity. High-dose (10 mM BAPTA induced rapid and complete cessation of rhythmic action potential (AP firing (time to cessation 5.5±1.7 s. Over a range of concentrations, BAPTA induced slowing of action potential firing and disruption of rhythmic activity, which was dose-dependent in its time of onset. Exposure to BAPTA was associated with stereotyped action potential changes similar to those previously reported in the presence of ryanodine, namely depolarisation of the most negative diastolic potential, prolongation of action potentials and a reduction in action potential amplitude. These experiments are consistent with the view that cytosolic calcium is essential to the maintenance of rhythmic pacemaker activity.

  16. The hidden sentinel node in breast cancer

    NARCIS (Netherlands)

    Tanis, P. J.; van Sandick, J. W.; Nieweg, O. E.; Valdés Olmos, R. A.; Rutgers, E. J. T.; Hoefnagel, C. A.; Kroon, B. B. R.

    2002-01-01

    The purpose of this study was to analyse the occurrence of non-visualisation during preoperative lymphoscintigraphy for sentinel node identification in breast cancer. Preoperative lymphoscintigraphy was performed in 495 clinically node-negative breast cancer patients (501 sentinel node procedures)

  17. T.Node, industrial version of supernode

    Science.gov (United States)

    Flieller, Sylvain

    1989-12-01

    The Esprit I P1085 "SuperNode" project developed a modular reconfigurable archtecture, based on transputers. This highly parallel machine is now marketed by Telmat Informatique under the name T.Node. This paper presents the P1085 project, the architecture of SuperNode, its industrial implementation and its software enviroment.

  18. CT perfusion study of neck lymph nodes

    International Nuclear Information System (INIS)

    Zhong Jin; Liu Jun; Hua Rui; Qiao Hui; Gong Yi

    2011-01-01

    Objective: To study the CT perfusion features of various lymph nodes in the neck. Methods: Dynamic perfusion CT scanning was performed in 83 neck lymph nodes proved by pathology, including tuberculosis lymph nodes, lymphoma and metastatic lymph nodes. The shapes, blood flow modes, and perfusion parameters of these lymph nodes were compared among 3 groups. Statistical analysis of L/T and CT perfusion parameters was performed by one-way ANOVA and LSD test. Results: The values of MTT of tuberculosis lymph nodes, lymphoma and metastatic lymph nodes were (28.13±5.08), (31.08±5.82), and (11.24±5.31) s, respectively. The MTT of metastatic lymph nodes was statistically lower than that of tuberculosis lymph nodes and lymphoma (P -1 · 100 g -1 , respectively. The values of BV were (24.68±2.84), (25.30±3.16), and (25.15± 8.81) ml·100 g -1 respectively. The values of TTP were (40.90±8.85), (40.67±6.45), and (40.98±6.62) s, respectively. There were no significant differences in L/T, BF, BV and TTP among tuberculosis lymph nodes, lymphoma and metastatic lymph nodes (P>0.05). Conclusion: CT perfusion, especially combination functional imaging with perfusion images may be helpful in judging the nature of neck lymph nodes. (authors)

  19. Sentinel node concept in breast cancer

    International Nuclear Information System (INIS)

    Kiricuta, I.C.

    2000-01-01

    Background/purpose: It seems that there exists a specific lymph node center called sentinel node (SN) which appears to be the primary site of metastases. The sentinel node concept (SNC) is fundamentally based on the orderly progression of tumor cells within the lymphatic system. It is the most important new concept in surgical and radiation oncology. The purpose is to present the biological significance, the diagnostic and clinical basis of the sentinel node concept in breast cancer patients. Material and methods: Lymphoscintigraphy and gamma probe biopsy is necessary to show predictable lymph flow to the regional sentinel node, to multiple sentinel nodes or unpredictable lymph flow to extra-regional sentinel nodes and for performing sentinel node procedure. The standard protocol for the evaluation of the sentinel node metastases consists of extensive histopathological investigation including step Hematoxylin and Eosin (H and E) stained sections and immunohistochemistry. Results: A high rate of success of the identification of the sentinel node for breast cancer was reported. The presence or absence of metastasis in this node is a very accurate predictor of overall nodal status. The temptation to examine the sentinel node with the greatest possible degree of accuracy highlights one of the major problems related to sentinel node biopsy. The success of the sentinel node procedure depends primarily on the adequate functional capacity necessary for sufficient uptake to ensure the accurate identification. In negative sentinel-node patients a complete axillary lymph node dissection is avoidable. In sentinel-node positive patients and clinically negative patients a postoperative radiotherapy would permit an adequate tumor control. The last 2-procedures permit a low morbidity. In the actual TNM classification it was recently introduced a definition of a 'pN0' patient based on sentinel node biopsy. New target volumes are defined for adjuvant radiotherapy or lymphatic basins

  20. Offloading of a Wireless Node Authentication with Core Network

    DEFF Research Database (Denmark)

    2017-01-01

    An example technique may include controlling receiving, by a second node from a first node in a wireless network, a request to offload authentication of the first node with the core network to the second node, controlling receiving, by the second node from the first node, data to be forwarded...... to the core network, performing, by the second node based on the request, an authentication with the core network on behalf of the first node while the first node is not connected with the second node, and controlling forwarding the received data from the second node to the core network while the first node...

  1. Sentinel lymph node biopsy in oral cancer

    DEFF Research Database (Denmark)

    Thomsen, Jørn Bo; Sørensen, Jens Ahm; Grupe, Peter

    2005-01-01

    PURPOSE: To validate lymphatic mapping combined with sentinel lymph node biopsy as a staging procedure, and to evaluate the possible clinical implications of added oblique lymphoscintigraphy and/or tomography and test the intra- and interobserver reproducibility of lymphoscintigraphy. MATERIAL......: Eleven (28%) patients were upstaged. The sentinel lymph node identification rate was 97.5%. Sentinel lymph node biopsy significantly differentiated between patients with or without lymph node metastasis (P = 0.001). Lymphatic mapping revealed 124 hotspots and 144 hot lymph nodes were removed by sentinel...

  2. Pattern of Colon Cancer Lymph Node Metastases in Patients Undergoing Central Mesocolic Lymph Node Excision

    DEFF Research Database (Denmark)

    Bertelsen, Claus A; Kirkegaard-Klitbo, Anders; Nielsen, Mingyuan

    2016-01-01

    BACKGROUND: Extended mesocolic lymph node dissection in colon cancer surgery seems to improve oncological outcome. A possible reason might be related to metastases in the central mesocolic lymph nodes. OBJECTIVE: The purpose of this study was to describe the pattern of mesocolic lymph node...... metastases, particularly in central lymph nodes, and the risk of skip, aberrant, and gastrocolic ligament metastases as the argument for performing extended lymph node dissection. DATA SOURCES: EMBASE and PubMed were searched using the terms colon or colorectal with sentinel node, lymph node mapping, or skip...... node; lymph node resection colon; and complete or total and mesocolic excision. STUDY SELECTION: Studies describing the risk of metastases in central, skip, aberrant, and gastrocolic ligament lymph node metastases from colon adenocarcinomas in 10 or more patients were included. No languages were...

  3. Targeted Delivery of Immunomodulators to Lymph Nodes

    Directory of Open Access Journals (Sweden)

    Jamil Azzi

    2016-05-01

    Full Text Available Active-targeted delivery to lymph nodes represents a major advance toward more effective treatment of immune-mediated disease. The MECA79 antibody recognizes peripheral node addressin molecules expressed by high endothelial venules of lymph nodes. By mimicking lymphocyte trafficking to the lymph nodes, we have engineered MECA79-coated microparticles containing an immunosuppressive medication, tacrolimus. Following intravenous administration, MECA79-bearing particles showed marked accumulation in the draining lymph nodes of transplanted animals. Using an allograft heart transplant model, we show that targeted lymph node delivery of microparticles containing tacrolimus can prolong heart allograft survival with negligible changes in tacrolimus serum level. Using MECA79 conjugation, we have demonstrated targeted delivery of tacrolimus to the lymph nodes following systemic administration, with the capacity for immune modulation in vivo.

  4. Sentinel node biopsy before neoadjuvant chemotherapy spares breast cancer patients axillary lymph node dissection.

    Science.gov (United States)

    van Rijk, Maartje C; Nieweg, Omgo E; Rutgers, Emiel J T; Oldenburg, Hester S A; Olmos, Renato Valdés; Hoefnagel, Cornelis A; Kroon, Bin B R

    2006-04-01

    Neoadjuvant chemotherapy in breast cancer patients is a valuable method to determine the efficacy of chemotherapy and potentially downsize the primary tumor, which facilitates breast-conserving therapy. In 18 studies published about sentinel node biopsy after neoadjuvant chemotherapy, the sentinel node was identified in on average 89%, and the false-negative rate was on average 10%. Because of these mediocre results, no author dares to omit axillary clearance just yet. In our institute, sentinel lymph node biopsy is performed before neoadjuvant chemotherapy. The aim of this study was to evaluate our experience with this approach. Sentinel node biopsy was performed before neoadjuvant chemotherapy in 25 T2N0 patients by using lymphoscintigraphy, a gamma ray detection probe, and patent blue dye. Axillary lymph node dissection was performed after chemotherapy if the sentinel node contained metastases. Ten patients had a tumor-positive axillary sentinel node, and one patient had an involved lateral intramammary node. Four patients had additional involved nodes in the completion lymph node dissection specimen. The other 14 patients (56%) had a tumor-negative sentinel node and did not undergo axillary lymph node dissection. No recurrences have been observed after a median follow-up of 18 months. Fourteen (56%) of the 25 patients were spared axillary lymph node dissection when the sentinel node was found to be disease free. Performing sentinel node biopsy before neoadjuvant chemotherapy seems successful and reliable in patients with T2N0 breast cancer.

  5. Node-pair reliability of network systems with small distances between adjacent nodes

    International Nuclear Information System (INIS)

    Malinowski, Jacek

    2007-01-01

    A new method for computing the node-pair reliability of network systems modeled by random graphs with nodes arranged in sequence is presented. It is based on a recursive algorithm using the 'sliding window' technique, the window being composed of several consecutive nodes. In a single step, the connectivity probabilities for all nodes included in the window are found. Subsequently, the window is moved one node forward. This process is repeated until, in the last step, the window reaches the terminal node. The connectivity probabilities found at that point are used to compute the node-pair reliability of the network system considered. The algorithm is designed especially for graphs with small distances between adjacent nodes, where the distance between two nodes is defined as the absolute value of the difference between the nodes' numbers. The maximal distance between any two adjacent nodes is denoted by Γ(G), where G symbolizes a random graph. If Γ(G)=2 then the method can be applied for directed as well as undirected graphs whose nodes and edges are subject to failure. This is important in view of the fact that many algorithms computing network reliability are designed for graphs with failure-prone edges and reliable nodes. If Γ(G)=3 then the method's applicability is limited to undirected graphs with reliable nodes. The main asset of the presented algorithms is their low numerical complexity-O(n), where n denotes the number of nodes

  6. Lymphoscintigraphic diagnosis of the lymph node metastasis of esophageal cancer

    International Nuclear Information System (INIS)

    Terui, Shoji; Kawai, Hideo; Hirashima, Toshio; Yamaguchi, Hajime; Kato, Hoichi; Iizuka, Norifumi

    1985-01-01

    Lymphoscintigraphy with 99m Tc-labeled rhenium sulfur colloid was performed preoperatively in 30 patients with esopohageal cancer. It showed hot nodes in a total of 267 lymph nodes, 176 mediastinal nodes and 91 celiac artery nodes. Of these 267 nodes, 47 (18 %) were found to have metastasis, including 34 (19 %) mediastinal nodes and 13 (14 %) celiac artery nodes. On the other hand, the number of non-visualized lymph nodes (cold nodes) was 542. Of them, 78 (14 %) had metastasis; 46 (15 %) were mediastinal nodes and 32 (14 %) were celiac artery nodes. (Namekawa, K.)

  7. Localizing and placement of network node functions in a network

    NARCIS (Netherlands)

    Strijkers, R.J.; Meulenhoff, P.J.

    2014-01-01

    The invention enables placement and use of a network node function in a second network node instead of using the network node function in a first network node. The network node function is e.g. a server function or a router function. The second network node is typically located in or close to the

  8. The hidden sentinel node in breast cancer

    International Nuclear Information System (INIS)

    Tanis, P.J.; Sandick, J.W. van; Nieweg, O.E.; Rutgers, E.J.T.; Kroon, B.B.R.; Valdes Olmos, R.A.; Hoefnagel, C.A.

    2002-01-01

    The purpose of this study was to analyse the occurrence of non-visualisation during preoperative lymphoscintigraphy for sentinel node identification in breast cancer. Preoperative lymphoscintigraphy was performed in 495 clinically node-negative breast cancer patients (501 sentinel node procedures) after injection of technetium-99m nanocolloid. Anterior and prone lateral (hanging breast) planar images were obtained a few minutes and 4 h after injection. The sentinel node was intraoperatively identified with the aid of patent blue dye and a gamma-ray detection probe. A sentinel node was visualised on the 4-h images in 449 of 501 procedures (90%). This visualisation rate improved from 76% to 94% during the study period. Delayed imaging (5-23 h) in 19 patients whose sentinel nodes failed to show, resulted in visualisation in four of them. A repeat injection of radiocolloid in 11 patients revealed a sentinel node in six. In the end, the visualisation rate was 92%. The sentinel node was surgically retrieved in 24 of the remaining 42 patients with non-visualisation (57%). Sentinel nodes that were visualised were tumour-positive in 38% and non-visualised sentinel nodes were involved in 50% (χ 2 , P=0.17). In a multivariate regression analysis, scintigraphic non-visualisation was independently associated with increased patient age (P<0.001), decreased tracer dose (P<0.001) and increased number of tumour-positive lymph nodes (P=0.013). The use of a sufficient amount of radioactivity (at least 100 MBq) is recommended for lymphatic mapping in breast cancer, especially in elderly women. Delayed imaging and re-injection of the radioactive tracer increase the visualisation rate. The non-visualised sentinel node can be identified intraoperatively in more than half of the patients. (orig.)

  9. The hidden sentinel node in breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Tanis, P.J.; Sandick, J.W. van; Nieweg, O.E.; Rutgers, E.J.T.; Kroon, B.B.R. [Department of Surgery, Netherlands Cancer Institute, Amsterdam (Netherlands); Valdes Olmos, R.A.; Hoefnagel, C.A. [Department of Nuclear Medicine, Netherlands Cancer Institute, Amsterdam (Netherlands)

    2002-03-01

    The purpose of this study was to analyse the occurrence of non-visualisation during preoperative lymphoscintigraphy for sentinel node identification in breast cancer. Preoperative lymphoscintigraphy was performed in 495 clinically node-negative breast cancer patients (501 sentinel node procedures) after injection of technetium-99m nanocolloid. Anterior and prone lateral (hanging breast) planar images were obtained a few minutes and 4 h after injection. The sentinel node was intraoperatively identified with the aid of patent blue dye and a gamma-ray detection probe. A sentinel node was visualised on the 4-h images in 449 of 501 procedures (90%). This visualisation rate improved from 76% to 94% during the study period. Delayed imaging (5-23 h) in 19 patients whose sentinel nodes failed to show, resulted in visualisation in four of them. A repeat injection of radiocolloid in 11 patients revealed a sentinel node in six. In the end, the visualisation rate was 92%. The sentinel node was surgically retrieved in 24 of the remaining 42 patients with non-visualisation (57%). Sentinel nodes that were visualised were tumour-positive in 38% and non-visualised sentinel nodes were involved in 50% ({chi}{sup 2}, P=0.17). In a multivariate regression analysis, scintigraphic non-visualisation was independently associated with increased patient age (P<0.001), decreased tracer dose (P<0.001) and increased number of tumour-positive lymph nodes (P=0.013). The use of a sufficient amount of radioactivity (at least 100 MBq) is recommended for lymphatic mapping in breast cancer, especially in elderly women. Delayed imaging and re-injection of the radioactive tracer increase the visualisation rate. The non-visualised sentinel node can be identified intraoperatively in more than half of the patients. (orig.)

  10. Gammascintigraphy of metastases of the lymph nodes

    International Nuclear Information System (INIS)

    Mechev, D.S.; Shishkina, V.V.

    1985-01-01

    It was indicated that according to the degree of informative value all the methods used in this study can be listed as follows: the method of combined use of positive and negative scintigraphy, the method of positive scintigraphy with Ga 67 -citrate (the tymph nodes above the diagram) and Tc 99 -pertechnate (the lymph nodes below the diaphragm), the method of indirect radionuclide lymphography with colloids. The main indices of radionuclide methods in the diagnosis of the lymph node metastatic involvement are presented

  11. The complex network reliability and influential nodes

    Science.gov (United States)

    Li, Kai; He, Yongfeng

    2017-08-01

    In order to study the complex network node important degree and reliability, considering semi-local centrality, betweenness centrality and PageRank algorithm, through the simulation method to gradually remove nodes and recalculate the importance in the random network, small world network and scale-free network. Study the relationship between the largest connected component and node removed proportion, the research results show that betweenness centrality and PageRank algorithm based on the global information network are more effective for evaluating the importance of nodes, and the reliability of the network is related to the network topology.

  12. Sentinel node concept in breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kiricuta, I.C. [St. Vincenz-Hospital, Limburg (Germany). Inst. for Radiation Oncology

    2000-07-01

    Background/purpose: It seems that there exists a specific lymph node center called sentinel node (SN) which appears to be the primary site of metastases. The sentinel node concept (SNC) is fundamentally based on the orderly progression of tumor cells within the lymphatic system. It is the most important new concept in surgical and radiation oncology. The purpose is to present the biological significance, the diagnostic and clinical basis of the sentinel node concept in breast cancer patients. Material and methods: Lymphoscintigraphy and gamma probe biopsy is necessary to show predictable lymph flow to the regional sentinel node, to multiple sentinel nodes or unpredictable lymph flow to extra-regional sentinel nodes and for performing sentinel node procedure. The standard protocol for the evaluation of the sentinel node metastases consists of extensive histopathological investigation including step Hematoxylin and Eosin (H and E) stained sections and immunohistochemistry. Results: A high rate of success of the identification of the sentinel node for breast cancer was reported. The presence or absence of metastasis in this node is a very accurate predictor of overall nodal status. The temptation to examine the sentinel node with the greatest possible degree of accuracy highlights one of the major problems related to sentinel node biopsy. The success of the sentinel node procedure depends primarily on the adequate functional capacity necessary for sufficient uptake to ensure the accurate identification. In negative sentinel-node patients a complete axillary lymph node dissection is avoidable. In sentinel-node positive patients and clinically negative patients a postoperative radiotherapy would permit an adequate tumor control. The last 2-procedures permit a low morbidity. In the actual TNM classification it was recently introduced a definition of a 'pN0' patient based on sentinel node biopsy. New target volumes are defined for adjuvant radiotherapy or

  13. Sentinel Node Biopsy Alone versus Completion Axillary Node Dissection in Node Positive Breast Cancer: Systematic Review and Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Rachna Ram

    2014-01-01

    Full Text Available Introduction. There has been recent interest in validity of completion axillary node dissection after a positive sentinel node. This systematic review aims to ascertain if sentinel lymph node dissection alone was noninferior to axillary lymph node dissection for breast cancer patients who have a positive sentinel node. Method. A systematic review of the electronic databases Embase, MEDLINE, and Cochrane Register of Controlled Trials was carried out. Only randomised trials that had patients with positive sentinel node as the study sample were included in the meta-analysis using the reported hazard ratios with a fixed effect model. Results. Three randomised controlled trials and five retrospective studies were identified. The pooled effect for overall survival was HR 0.94, 95% CI [0.79, 1.19], and for disease free survival was HR 0.83, 95% CI [0.60, 1.14]. The reported rates for locoregional recurrence were similar in both groups. The surgical morbidity was found to be significantly more in patients who had underwent axillary dissection. Conclusion. Amongst patients with micrometastasis in the sentinel node, no further axillary dissection is necessary. For patients with macrometastasis in the sentinel node, it is reasonable to consider omitting axillary dissection to avoid the morbidity of the procedure.

  14. Manned Flight Simulator (MFS)

    Data.gov (United States)

    Federal Laboratory Consortium — The Aircraft Simulation Division, home to the Manned Flight Simulator (MFS), provides real-time, high fidelity, hardware-in-the-loop flight simulation capabilities...

  15. Penile Cancer: Contemporary Lymph Node Management.

    Science.gov (United States)

    O'Brien, Jonathan S; Perera, Marlon; Manning, Todd; Bozin, Mike; Cabarkapa, Sonja; Chen, Emily; Lawrentschuk, Nathan

    2017-06-01

    In penile cancer, the optimal diagnostics and management of metastatic lymph nodes are not clear. Advances in minimally invasive staging, including dynamic sentinel lymph node biopsy, have widened the diagnostic repertoire of the urologist. We aimed to provide an objective update of the recent trends in the management of penile squamous cell carcinoma, and inguinal and pelvic lymph node metastases. We systematically reviewed several medical databases, including the Web of Science® (with MEDLINE®), Embase® and Cochrane databases, according to PRISMA (Preferred Reporting Items for Systematic Review and Meta-Analyses) guidelines. The search terms used were penile cancer, lymph node, sentinel node, minimally invasive, surgery and outcomes, alone and in combination. Articles pertaining to the management of lymph nodes in penile cancer were reviewed, including original research, reviews and clinical guidelines published between 1980 and 2016. Accurate and minimally invasive lymph node staging is of the utmost importance in the surgical management of penile squamous cell carcinoma. In patients with clinically node negative disease, a growing body of evidence supports the use of sentinel lymph node biopsies. Dynamic sentinel lymph node biopsy exposes the patient to minimal risk, and results in superior sensitivity and specificity profiles compared to alternate nodal staging techniques. In the presence of locoregional disease, improvements in inguinal or pelvic lymphadenectomy have reduced morbidity and improved oncologic outcomes. A multimodal approach of chemotherapy and surgery has demonstrated a survival benefit for patients with advanced disease. Recent developments in lymph node management have occurred in penile cancer, such as minimally invasive lymph node diagnosis and intervention strategies. These advances have been met with a degree of controversy in the contemporary literature. Current data suggest that dynamic sentinel lymph node biopsy provides excellent

  16. Enhancement characteristics of retroperitoneal lymphomatous lymph nodes

    International Nuclear Information System (INIS)

    Hagtvedt, Trond; Smith, Hans-Joergen; Kolbenstvedt, Alf; Aaloekken, Trond Mogens; Graff, Bjoern Anton; Holte, Harald

    2013-01-01

    Background: Previous studies of CT enhancement of lymphomatous lymph nodes (LLN) of the neck and the mediastinum showed that the LLN had lower enhancement values than normal lymph nodes. Purpose: To elucidate the contrast medium enhancement curves of LLN in the retroperitoneum by comparing the curves of LLN with those of normal lymph nodes, to test whether differences between these curves could be of diagnostic value, and to compare the present enhancement curves of LLN of the retroperitoneum with the curves of LLN of the neck and the mediastinum from previous similar investigations. Material and Methods: Twenty-eight consecutive patients with LLN of the retroperitoneum (three with Hodgkin's lymphoma [HL]) and 21 control patients with sarcomas and thus presumably normal retroperitoneal nodes underwent dynamic CT examinations. The previous, similar investigation of lymph nodes of the neck comprised 28 patients with LLN and the investigation of mediastinal lymph nodes comprised 24 patients with LLN. Results: The enhancement curves of the retroperitoneal LLN had significantly lower attenuation than those of the retroperitoneal control nodes. A combination of peak contrast value and time to peak adjusted to total body weight yielded a diagnostic accuracy which at the best showed a sensitivity of 90.5% with a specificity of 82.6%. The LLN of the retroperitoneum had higher attenuation values than corresponding nodes of the mediastinum but no significant difference was found between LLN of the retroperitoneum and LLN of the neck in previous similar investigations. Conclusion: The comparison of enhancement curves of retroperitoneal LLN with retroperitoneal control nodes showed a marked similarity with and substantiates our previous findings in lymph nodes of the neck and of the mediastinum. The best diagnostic accuracy was achieved by combining the parameters peak contrast value and time to peak and adjusting these values to the body weight. Peak enhancement of the

  17. Ethernet for Space Flight Applications

    Science.gov (United States)

    Webb, Evan; Day, John H. (Technical Monitor)

    2002-01-01

    NASA's Goddard Space Flight Center (GSFC) is adapting current data networking technologies to fly on future spaceflight missions. The benefits of using commercially based networking standards and protocols have been widely discussed and are expected to include reduction in overall mission cost, shortened integration and test (I&T) schedules, increased operations flexibility, and hardware and software upgradeability/scalability with developments ongoing in the commercial world. The networking effort is a comprehensive one encompassing missions ranging from small University Explorer (UNEX) class spacecraft to large observatories such as the Next Generation Space Telescope (NGST). Mission aspects such as flight hardware and software, ground station hardware and software, operations, RF communications, and security (physical and electronic) are all being addressed to ensure a complete end-to-end system solution. One of the current networking development efforts at GSFC is the SpaceLAN (Spacecraft Local Area Network) project, development of a space-qualifiable Ethernet network. To this end we have purchased an IEEE 802.3-compatible 10/100/1000 Media Access Control (MAC) layer Intellectual Property (IP) core and are designing a network node interface (NNI) and associated network components such as a switch. These systems will ultimately allow the replacement of the typical MIL-STD-1553/1773 and custom interfaces that inhabit most spacecraft. In this paper we will describe our current Ethernet NNI development along with a novel new space qualified physical layer that will be used in place of the standard interfaces. We will outline our plans for development of space qualified network components that will allow future spacecraft to operate in significant radiation environments while using a single onboard network for reliable commanding and data transfer. There will be a brief discussion of some issues surrounding system implications of a flight Ethernet. Finally, we will

  18. Insect flight muscle metabolism

    NARCIS (Netherlands)

    Horst, D.J. van der; Beenakkers, A.M.Th.; Marrewijk, W.J.A. van

    1984-01-01

    The flight of an insect is of a very complicated and extremely energy-demanding nature. Wingbeat frequency may differ between various species but values up to 1000 Hz have been measured. Consequently metabolic activity may be very high during flight and the transition from rest to flight is

  19. Localized Lymph Node Light Chain Amyloidosis

    Directory of Open Access Journals (Sweden)

    Binod Dhakal

    2015-01-01

    Full Text Available Immunoglobulin-derived light chain amyloidosis can occasionally be associated with localized disease. We present a patient with localized lymph node light chain amyloidosis without an underlying monoclonal protein or lymphoproliferative disorder and review the literature of lymph node amyloidosis discussing work-up and risk factors for systemic progression.

  20. Sentinel lymph node identification with magnetic nanoparticles

    NARCIS (Netherlands)

    Pouw, Joost Jacob

    2016-01-01

    Most solid malignancies have a tendency to spread through the lymphatic system to locoregional lymph nodes. Presence of metastasis is an important prognostic factor, and is used to determine the optimal treatment of the patient. The sentinel lymph nodes (SLNs) receive direct lymphatic drainage from

  1. Testnodes: a Lightweight node-testing infrastructure

    International Nuclear Information System (INIS)

    Fay, R; Bland, J

    2014-01-01

    A key aspect of ensuring optimum cluster reliability and productivity lies in keeping worker nodes in a healthy state. Testnodes is a lightweight node testing solution developed at Liverpool. While Nagios has been used locally for general monitoring of hosts and services, Testnodes is optimised to answer one question: is there any reason this node should not be accepting jobs? This tight focus enables Testnodes to inspect nodes frequently with minimal impact and provide a comprehensive and easily extended check with each inspection. On the server side, Testnodes, implemented in python, interoperates with the Torque batch server to control the nodes production status. Testnodes remotely and in parallel executes client-side test scripts and processes the return codes and output, adjusting the node's online/offline status accordingly to preserve the integrity of the overall batch system. Testnodes reports via log, email and Nagios, allowing a quick overview of node status to be reviewed and specific node issues to be identified and resolved quickly. This presentation will cover testnodes design and implementation, together with the results of its use in production at Liverpool, and future development plans.

  2. Contrast enhanced ultrasound of sentinel lymph nodes

    Directory of Open Access Journals (Sweden)

    XinWu Cui

    2013-03-01

    Full Text Available Sentinel lymph nodes are the first lymph nodes in the region that receive lymphatic drainage from a primary tumor. The detection or exclusion of sentinel lymph node micrometastases is critical in the staging of cancer, especially breast cancer and melanoma because it directly affects patient’s prognosis and surgical management. Currently, intraoperative sentinel lymph node biopsies using blue dye and radioisotopes are the method of choice for the detection of sentinel lymph node with high identification rate. In contrast, conventional ultrasound is not capable of detecting sentinel lymph nodes in most cases. Contrast enhanced ultrasound with contrast specific imaging modes has been used for the evaluation and diagnostic work-up of peripherally located suspected lymphadenopathy. The method allows for real-time analysis of all vascular phases and the visualization of intranodal focal “avascular” areas that represent necrosis or deposits of neoplastic cells. In recent years, a number of animal and human studies showed that contrast enhanced ultrasound can be also used for the detection of sentinel lymph node, and may become a potential application in clinical routine. Several contrast agents have been used in those studies, including albumin solution, hydroxyethylated starch, SonoVue®, Sonazoid® and Definity®. This review summarizes the current knowledge about the use of ultrasound techniques in detection and evaluation of sentinel lymph node.

  3. Sentinel lymph node imaging in breast cancer

    International Nuclear Information System (INIS)

    Kim, Byung Tae

    1999-01-01

    Currently, dissection of the axillary or regional lymph nodes is considered the standard staging procedure in breast cancer. However, accumulating evidence is becoming available that the sentinel node concept may provide the same or even better staging information. In the case of melanoma, it is proven that the histological characteristics of the sentinel node reflect the histological characteristics of the distal part of the lymphatic basin. Morbidity can be reduced significantly by the use of sentinel node dissection as several authors have reported successful introduction of this technique into clinical practice. But in breast cancer patients, there are significant differences in practice relating to the technology, such as radiopharmaceuticals, injection sites, volume of injectate, combination with vital blue dye, preoperative lymphoscintigraphy, etc. Valuable reports on these topics appeared in recent journals. This review is a summary of those reports for nuclear physicians interested in sentinel node detection by lymphoscintigraphy in breast cancer patients

  4. Sentinel lymph node biopsy: clinical relevance

    International Nuclear Information System (INIS)

    Howman-Giles, R.

    2002-01-01

    Sentinel lymph node biopsy (SLNB) has become an important technique in the management of patients with intermediate level melanoma, clinical operable breast cancer and some other cancers. The technique relies on lymphatic mapping to define the lymph drainage from a primary tumour with the premise that the lymph nodes, which directly drain from that area, will reflect the tumour status of the remainder of the node field. Current techniques use lymphoscintigraphy where a radioactive labelled particle and / or blue dye are injected intradermally or intraparenchymally to map the lymph drainage, often in conjunction with a radioactive gamma probe at surgery. In patients with melanoma the SLNB has improved the staging and prognostic information by more accurate determination of whether regional lymph nodes have metastatic spread. This has a major impact on patient management as those patients with negative nodes do not require regional lymph node dissection and have a significantly better prognosis. In our experience of over 3000 patients the combined sentinel node biopsy technique localised accurately 98% of sentinel lymph nodes. Lymphoscintigraphy in patients with melanoma to locate the sentinel lymph nodes involves the intradermal injection of a radiocolloid around the melanoma site or the excision biopsy site. Injections of 5 -10 MBq in 0.05-0.1ml/inj are used and typically 4 injections are usually required. Following tracer injection dynamic imaging is performed to follow the lymphatic collecting vessels until they reach the draining sentinel nodes. An image should be acquired as the vessels reach the node field so that the sentinel nodes directly receiving the channels can be identified and distinguished from any second tier nodes which may sometimes be seen. Delayed scans are performed 2 hours later at which time all regions which can possible drain the primary melanoma site are examined with 5-10 minute static images. The surface location of all sentinel nodes is

  5. Isolated perifacial lymph node metastasis in oral squamous cell carcinoma with clinically node-negative neck.

    Science.gov (United States)

    Agarwal, Sangeet Kumar; Arora, Sowrabh Kumar; Kumar, Gopal; Sarin, Deepak

    2016-10-01

    The incidence of occult perifacial nodal disease in oral cavity squamous cell carcinoma is not well reported. The purpose of this study was to evaluate the incidence of isolated perifacial lymph node metastasis in patients with oral squamous cell carcinoma with a clinically node-negative neck. The study will shed light on current controversies and will provide valuable clinical and pathological information in the practice of routine comprehensive removal of these lymph node pads in selective neck dissection in the node-negative neck. Prospective analysis. This study was started in August 2011 when intraoperatively we routinely separated the lymph node levels from the main specimen for evaluation of the metastatic rate to different lymph node levels in 231 patients of oral squamous cell cancer with a clinically node-negative neck. The current study demonstrated that 19 (8.22%) out of 231 patients showed ipsilateral isolated perifacial lymph node involvement. The incidence of isolated perifacial nodes did not differ significantly between the oral tongue (7.14%) and buccal mucosa (7.75%). Incidence was statistically significant in cases with lower age group (oral squamous cell carcinoma with a clinically node-negative neck. The incidence of isolated perifacial involvement is high in cases of buccal mucosal and tongue cancers. A meticulous dissection of the perifacial nodes seems prudent when treating the neck in oral cavity squamous cell carcinoma. 4 Laryngoscope, 126:2252-2256, 2016. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  6. Air launch wireless sensor nodes (ALSN) for battle damage assessment (BDA)

    Science.gov (United States)

    Back, Jason M.; Beck, Steven D.; Frank, Mark A.; Hoenes, Eric

    2006-05-01

    This paper summarizes the Defense Threat Reduction Agency (DTRA) sponsored development and demonstration of an Air Launched Sensor Node (ALSN) system designed to fill DTRA's immediate need to support the Global Strike requirement of weapon-borne deliverable sensors for Battle Damage Assessment (BDA). Unattended ground sensors were integrated into a CBU-103 Tactical Munitions Dispenser (TMD), and flight test demonstrated with the 46 th Test Wing at Eglin AFB, FL. The objectives of the ALSN program were to repackage an existing multi-sensor node system to conform to the payload envelope and deployment configuration design; to integrate this payload into the CBU-103 TMD; and to conduct a combined payload flight test demonstration. The final sensor node included multiple sensors a microphone, a geophone, and multiple directional Passive Infrared (PIR) detectors with processing electronics, a low power wireless communications 802.15.4 mesh network, GPS (Global Positioning System), and power integrated into a form-fit BLU-97 munitions deployable package. This paper will present and discuss the flight test, results, and ALSN performance.

  7. Methylation signature of lymph node metastases in breast cancer patients

    International Nuclear Information System (INIS)

    Barekati, Zeinab; Radpour, Ramin; Lu, Qing; Bitzer, Johannes; Zheng, Hong; Toniolo, Paolo; Lenner, Per; Zhong, Xiao Yan

    2012-01-01

    Invasion and metastasis are two important hallmarks of malignant tumors caused by complex genetic and epigenetic alterations. The present study investigated the contribution of aberrant methylation profiles of cancer related genes, APC, BIN1, BMP6, BRCA1, CST6, ESR-b, GSTP1, P14 (ARF), P16 (CDKN2A), P21 (CDKN1A), PTEN, and TIMP3, in the matched axillary lymph node metastasis in comparison to the primary tumor tissue and the adjacent normal tissue from the same breast cancer patients to identify the potential of candidate genes methylation as metastatic markers. The quantitative methylation analysis was performed using the SEQUENOM’s EpiTYPER™ assay which relies on matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). The quantitative DNA methylation analysis of the candidate genes showed higher methylation proportion in the primary tumor tissue than that of the matched normal tissue and the differences were significant for the APC, BIN1, BMP6, BRCA1, CST6, ESR-b, P16, PTEN and TIMP3 promoter regions (P<0.05). Among those candidate methylated genes, APC, BMP6, BRCA1 and P16 displayed higher methylation proportion in the matched lymph node metastasis than that found in the normal tissue (P<0.05). The pathway analysis revealed that BMP6, BRCA1 and P16 have a role in prevention of neoplasm metastasis. The results of the present study showed methylation heterogeneity between primary tumors and metastatic lesion. The contribution of aberrant methylation alterations of BMP6, BRCA1 and P16 genes in lymph node metastasis might provide a further clue to establish useful biomarkers for screening metastasis

  8. Node Immunization with Time-Sensitive Restrictions

    Directory of Open Access Journals (Sweden)

    Wen Cui

    2016-12-01

    Full Text Available When we encounter a malicious rumor or an infectious disease outbreak, immunizing k nodes of the relevant network with limited resources is always treated as an extremely effective method. The key challenge is how we can insulate limited nodes to minimize the propagation of those contagious things. In previous works, the best k immunised nodes are selected by learning the initial status of nodes and their strategies even if there is no feedback in the propagation process, which eventually leads to ineffective performance of their solutions. In this paper, we design a novel vaccines placement strategy for protecting much more healthy nodes from being infected by infectious nodes. The main idea of our solution is that we are not only utilizing the status of changing nodes as auxiliary knowledge to adjust our scheme, but also comparing the performance of vaccines in various transmission slots. Thus, our solution has a better chance to get more benefit from these limited vaccines. Extensive experiments have been conducted on several real-world data sets and the results have shown that our algorithm has a better performance than previous works.

  9. Defining nodes in complex brain networks

    Directory of Open Access Journals (Sweden)

    Matthew Lawrence Stanley

    2013-11-01

    Full Text Available Network science holds great promise for expanding our understanding of the human brain in health, disease, development, and aging. Network analyses are quickly becoming the method of choice for analyzing functional MRI data. However, many technical issues have yet to be confronted in order to optimize results. One particular issue that remains controversial in functional brain network analyses is the definition of a network node. In functional brain networks a node represents some predefined collection of brain tissue, and an edge measures the functional connectivity between pairs of nodes. The characteristics of a node, chosen by the researcher, vary considerably in the literature. This manuscript reviews the current state of the art based on published manuscripts and highlights the strengths and weaknesses of three main methods for defining nodes. Voxel-wise networks are constructed by assigning a node to each, equally sized brain area (voxel. The fMRI time-series recorded from each voxel is then used to create the functional network. Anatomical methods utilize atlases to define the nodes based on brain structure. The fMRI time-series from all voxels within the anatomical area are averaged and subsequently used to generate the network. Functional activation methods rely on data from traditional fMRI activation studies, often from databases, to identify network nodes. Such methods identify the peaks or centers of mass from activation maps to determine the location of the nodes. Small (~10-20 millimeter diameter spheres located at the coordinates of the activation foci are then applied to the data being used in the network analysis. The fMRI time-series from all voxels in the sphere are then averaged, and the resultant time series is used to generate the network. We attempt to clarify the discussion and move the study of complex brain networks forward. While the correct method to be used remains an open, possibly unsolvable question that

  10. Advanced Wireless Sensor Nodes - MSFC

    Science.gov (United States)

    Varnavas, Kosta; Richeson, Jeff

    2017-01-01

    NASA field center Marshall Space Flight Center (Huntsville, AL), has invested in advanced wireless sensor technology development. Developments for a wireless microcontroller back-end were primarily focused on the commercial Synapse Wireless family of devices. These devices have many useful features for NASA applications, good characteristics and the ability to be programmed Over-The-Air (OTA). The effort has focused on two widely used sensor types, mechanical strain gauges and thermal sensors. Mechanical strain gauges are used extensively in NASA structural testing and even on vehicle instrumentation systems. Additionally, thermal monitoring with many types of sensors is extensively used. These thermal sensors include thermocouples of all types, resistive temperature devices (RTDs), diodes and other thermal sensor types. The wireless thermal board will accommodate all of these types of sensor inputs to an analog front end. The analog front end on each of the sensors interfaces to the Synapse wireless microcontroller, based on the Atmel Atmega128 device. Once the analog sensor output data is digitized by the onboard analog to digital converter (A/D), the data is available for analysis, computation or transmission. Various hardware features allow custom embedded software to manage battery power to enhance battery life. This technology development fits nicely into using numerous additional sensor front ends, including some of the low-cost printed circuit board capacitive moisture content sensors currently being developed at Auburn University.

  11. Efficient Graph Computation for Node2Vec

    OpenAIRE

    Zhou, Dongyan; Niu, Songjie; Chen, Shimin

    2018-01-01

    Node2Vec is a state-of-the-art general-purpose feature learning method for network analysis. However, current solutions cannot run Node2Vec on large-scale graphs with billions of vertices and edges, which are common in real-world applications. The existing distributed Node2Vec on Spark incurs significant space and time overhead. It runs out of memory even for mid-sized graphs with millions of vertices. Moreover, it considers at most 30 edges for every vertex in generating random walks, causin...

  12. Checkpointing for a hybrid computing node

    Science.gov (United States)

    Cher, Chen-Yong

    2016-03-08

    According to an aspect, a method for checkpointing in a hybrid computing node includes executing a task in a processing accelerator of the hybrid computing node. A checkpoint is created in a local memory of the processing accelerator. The checkpoint includes state data to restart execution of the task in the processing accelerator upon a restart operation. Execution of the task is resumed in the processing accelerator after creating the checkpoint. The state data of the checkpoint are transferred from the processing accelerator to a main processor of the hybrid computing node while the processing accelerator is executing the task.

  13. phylo-node: A molecular phylogenetic toolkit using Node.js.

    Science.gov (United States)

    O'Halloran, Damien M

    2017-01-01

    Node.js is an open-source and cross-platform environment that provides a JavaScript codebase for back-end server-side applications. JavaScript has been used to develop very fast and user-friendly front-end tools for bioinformatic and phylogenetic analyses. However, no such toolkits are available using Node.js to conduct comprehensive molecular phylogenetic analysis. To address this problem, I have developed, phylo-node, which was developed using Node.js and provides a stable and scalable toolkit that allows the user to perform diverse molecular and phylogenetic tasks. phylo-node can execute the analysis and process the resulting outputs from a suite of software options that provides tools for read processing and genome alignment, sequence retrieval, multiple sequence alignment, primer design, evolutionary modeling, and phylogeny reconstruction. Furthermore, phylo-node enables the user to deploy server dependent applications, and also provides simple integration and interoperation with other Node modules and languages using Node inheritance patterns, and a customized piping module to support the production of diverse pipelines. phylo-node is open-source and freely available to all users without sign-up or login requirements. All source code and user guidelines are openly available at the GitHub repository: https://github.com/dohalloran/phylo-node.

  14. Flight code validation simulator

    Science.gov (United States)

    Sims, Brent A.

    1996-05-01

    An End-To-End Simulation capability for software development and validation of missile flight software on the actual embedded computer has been developed utilizing a 486 PC, i860 DSP coprocessor, embedded flight computer and custom dual port memory interface hardware. This system allows real-time interrupt driven embedded flight software development and checkout. The flight software runs in a Sandia Digital Airborne Computer and reads and writes actual hardware sensor locations in which Inertial Measurement Unit data resides. The simulator provides six degree of freedom real-time dynamic simulation, accurate real-time discrete sensor data and acts on commands and discretes from the flight computer. This system was utilized in the development and validation of the successful premier flight of the Digital Miniature Attitude Reference System in January of 1995 at the White Sands Missile Range on a two stage attitude controlled sounding rocket.

  15. Flight control actuation system

    Science.gov (United States)

    Wingett, Paul T. (Inventor); Gaines, Louie T. (Inventor); Evans, Paul S. (Inventor); Kern, James I. (Inventor)

    2006-01-01

    A flight control actuation system comprises a controller, electromechanical actuator and a pneumatic actuator. During normal operation, only the electromechanical actuator is needed to operate a flight control surface. When the electromechanical actuator load level exceeds 40 amps positive, the controller activates the pneumatic actuator to offset electromechanical actuator loads to assist the manipulation of flight control surfaces. The assistance from the pneumatic load assist actuator enables the use of an electromechanical actuator that is smaller in size and mass, requires less power, needs less cooling processes, achieves high output forces and adapts to electrical current variations. The flight control actuation system is adapted for aircraft, spacecraft, missiles, and other flight vehicles, especially flight vehicles that are large in size and travel at high velocities.

  16. Bat flight: aerodynamics, kinematics and flight morphology.

    Science.gov (United States)

    Hedenström, Anders; Johansson, L Christoffer

    2015-03-01

    Bats evolved the ability of powered flight more than 50 million years ago. The modern bat is an efficient flyer and recent research on bat flight has revealed many intriguing facts. By using particle image velocimetry to visualize wake vortices, both the magnitude and time-history of aerodynamic forces can be estimated. At most speeds the downstroke generates both lift and thrust, whereas the function of the upstroke changes with forward flight speed. At hovering and slow speed bats use a leading edge vortex to enhance the lift beyond that allowed by steady aerodynamics and an inverted wing during the upstroke to further aid weight support. The bat wing and its skeleton exhibit many features and control mechanisms that are presumed to improve flight performance. Whereas bats appear aerodynamically less efficient than birds when it comes to cruising flight, they have the edge over birds when it comes to manoeuvring. There is a direct relationship between kinematics and the aerodynamic performance, but there is still a lack of knowledge about how (and if) the bat controls the movements and shape (planform and camber) of the wing. Considering the relatively few bat species whose aerodynamic tracks have been characterized, there is scope for new discoveries and a need to study species representing more extreme positions in the bat morphospace. © 2015. Published by The Company of Biologists Ltd.

  17. ARC Code TI: NodeMon

    Data.gov (United States)

    National Aeronautics and Space Administration — NodeMon is a resource utilization monitor tailored to the Altix architecture, but is applicable to any Linux system or cluster. It allows distributed resource...

  18. Capital Flight from Russia

    OpenAIRE

    Prakash Loungani; Paolo Mauro

    2000-01-01

    This paper documents the scale of capital flight from Russia, compares it with that observed in other countries, and reviews policy options. The evidence from other countries suggests that capital flight can be reversed once reforms take hold. The paper argues that capital flight from Russia can only be curbed through a medium-term reform strategy aimed at improving governance and macroeconomic performance, and strengthening the banking system. Capital controls result in costly distortions an...

  19. Theseus in Flight

    Science.gov (United States)

    1996-01-01

    The twin pusher propeller-driven engines of the Theseus research aircraft can be clearly seen in this photo, taken during a 1996 research flight at NASA's Dryden Flight Research Center, Edwards, California. The Theseus aircraft, built and operated by Aurora Flight Sciences Corporation, Manassas, Virginia, was a unique aircraft flown at NASA's Dryden Flight Research Center, Edwards, California, under a cooperative agreement between NASA and Aurora. Dryden hosted the Theseus program, providing hangar space and range safety for flight testing. Aurora Flight Sciences was responsible for the actual flight testing, vehicle flight safety, and operation of the aircraft. The Theseus remotely piloted aircraft flew its maiden flight on May 24, 1996, at Dryden. During its sixth flight on November 12, 1996, Theseus experienced an in-flight structural failure that resulted in the loss of the aircraft. As of the beginning of the year 2000, Aurora had not rebuilt the aircraft. Theseus was built for NASA under an innovative, $4.9 million fixed-price contract by Aurora Flight Sciences Corporation and its partners, West Virginia University, Morgantown, West Virginia, and Fairmont State College, Fairmont, West Virginia. The twin-engine, unpiloted vehicle had a 140-foot wingspan, and was constructed largely of composite materials. Powered by two 80-horsepower, turbocharged piston engines that drove twin 9-foot-diameter propellers, Theseus was designed to fly autonomously at high altitudes, with takeoff and landing under the active control of a ground-based pilot in a ground control station 'cockpit.' With the potential ability to carry 700 pounds of science instruments to altitudes above 60,000 feet for durations of greater than 24 hours, Theseus was intended to support research in areas such as stratospheric ozone depletion and the atmospheric effects of future high-speed civil transport aircraft engines. Instruments carried aboard Theseus also would be able to validate satellite

  20. Resilience against Misbehaving Nodes in Asynchronous Networks

    OpenAIRE

    Senejohnny, D.; Sundaram, S.; De Persis, C.; Tesi, P.

    2018-01-01

    Network systems are one of the most active research areas in the engineering community as they feature a paradigm shift from centralized to distributed control and computation. When dealing with network systems, a fundamental challenge is to ensure their functioning even when some of the network nodes do not operate as intended due to faults or attacks. The objective of this paper is to address the problem of resilient consensus in a context where the nodes have their own clocks, possibly ope...

  1. Node insertion in Coalescence Fractal Interpolation Function

    International Nuclear Information System (INIS)

    Prasad, Srijanani Anurag

    2013-01-01

    The Iterated Function System (IFS) used in the construction of Coalescence Hidden-variable Fractal Interpolation Function (CHFIF) depends on the interpolation data. The insertion of a new point in a given set of interpolation data is called the problem of node insertion. In this paper, the effect of insertion of new point on the related IFS and the Coalescence Fractal Interpolation Function is studied. Smoothness and Fractal Dimension of a CHFIF obtained with a node are also discussed

  2. Flight research and testing

    Science.gov (United States)

    Putnam, Terrill W.; Ayers, Theodore G.

    1989-01-01

    Flight research and testing form a critical link in the aeronautic research and development chain. Brilliant concepts, elegant theories, and even sophisticated ground tests of flight vehicles are not sufficient to prove beyond a doubt that an unproven aeronautical concept will actually perform as predicted. Flight research and testing provide the ultimate proof that an idea or concept performs as expected. Ever since the Wright brothers, flight research and testing were the crucible in which aeronautical concepts were advanced and proven to the point that engineers and companies are willing to stake their future to produce and design aircraft. This is still true today, as shown by the development of the experimental X-30 aerospace plane. The Dryden Flight Research Center (Ames-Dryden) continues to be involved in a number of flight research programs that require understanding and characterization of the total airplane in all the aeronautical disciplines, for example the X-29. Other programs such as the F-14 variable-sweep transition flight experiment have focused on a single concept or discipline. Ames-Dryden also continues to conduct flight and ground based experiments to improve and expand the ability to test and evaluate advanced aeronautical concepts. A review of significant aeronautical flight research programs and experiments is presented to illustrate both the progress being made and the challenges to come.

  3. Flight Standards Automation System -

    Data.gov (United States)

    Department of Transportation — FAVSIS supports Flight Standards Service (AFS) by maintaining their information on entities such as air carriers, air agencies, designated airmen, and check airmen....

  4. Lymph Node Micrometastases are Associated with Worse Survival in Patients with Otherwise Node-Negative Hilar Cholangiocarcinoma

    NARCIS (Netherlands)

    Mantel, Hendrik T. J.; Wiggers, Jim K.; Verheij, Joanne; Doff, Jan J.; Sieders, Egbert; van Gulik, Thomas M.; Gouw, Annette S. H.; Porte, Robert J.

    2015-01-01

    Background. Lymph node metastases on routine histology are a strong negative predictor for survival after resection of hilar cholangiocarcinoma. Additional immunohistochemistry can detect lymph node micrometastases in patients who are otherwise node negative, but the prognostic value is unsure. The

  5. Dynamically reassigning a connected node to a block of compute nodes for re-launching a failed job

    Science.gov (United States)

    Budnik, Thomas A [Rochester, MN; Knudson, Brant L [Rochester, MN; Megerian, Mark G [Rochester, MN; Miller, Samuel J [Rochester, MN; Stockdell, William M [Byron, MN

    2012-03-20

    Methods, systems, and products for dynamically reassigning a connected node to a block of compute nodes for re-launching a failed job that include: identifying that a job failed to execute on the block of compute nodes because connectivity failed between a compute node assigned as at least one of the connected nodes for the block of compute nodes and its supporting I/O node; and re-launching the job, including selecting an alternative connected node that is actively coupled for data communications with an active I/O node; and assigning the alternative connected node as the connected node for the block of compute nodes running the re-launched job.

  6. Lymph Node Yield as a Predictor of Survival in Pathologically Node Negative Oral Cavity Carcinoma.

    Science.gov (United States)

    Lemieux, Aaron; Kedarisetty, Suraj; Raju, Sharat; Orosco, Ryan; Coffey, Charles

    2016-03-01

    Even after a pathologically node-negative (pN0) neck dissection for oral cavity squamous cell carcinoma (SCC), patients may develop regional recurrence. In this study, we (1) hypothesize that an increased number of lymph nodes removed (lymph node yield) in patients with pN0 oral SCC predicts improved survival and (2) explore predictors of survival in these patients using a multivariable model. Case series with chart review. Administrative database analysis. The SEER database was queried for patients diagnosed with all-stage oral cavity SCC between 1988 and 2009 who were determined to be pN0 after elective lymph node dissection. Demographic and treatment variables were extracted. The association of lymph node yield with 5-year all-cause survival was studied with multivariable survival analyses. A total of 4341 patients with pN0 oral SCC were included in this study. The 2 highest lymph node yield quartiles (representing >22 nodes removed) were found to be significant predictors of overall survival (22-35 nodes: hazard ratio [HR] = 0.854, P = .031; 36-98 nodes: HR = 0.827, P = .010). Each additional lymph node removed during neck dissection was associated with increased survival (HR = 0.995, P = .022). These data suggest that patients with oral SCC undergoing elective neck dissection may experience an overall survival benefit associated with greater lymph node yield. Mechanisms behind the demonstrated survival advantage are unknown. Larger nodal dissections may remove a greater burden of microscopic metastatic disease, diminishing the likelihood of recurrence. Lymph node yield may serve as an objective measure of the adequacy of lymphadenectomy. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  7. Implementation of Multiple Host Nodes in Wireless Sensing Node Network System for Landslide Monitoring

    International Nuclear Information System (INIS)

    Bin Abas, Faizulsalihin; Takayama, Shigeru

    2015-01-01

    This paper proposes multiple host nodes in Wireless Sensing Node Network System (WSNNS) for landslide monitoring. As landslide disasters damage monitoring system easily, one major demand in landslide monitoring is the flexibility and robustness of the system to evaluate the current situation in the monitored area. For various reasons WSNNS can provide an important contribution to reach that aim. In this system, acceleration sensors and GPS are deployed in sensing nodes. Location information by GPS, enable the system to estimate network topology and enable the system to perceive the location in emergency by monitoring the node mode. Acceleration sensors deployment, capacitate this system to detect slow mass movement that can lead to landslide occurrence. Once deployed, sensing nodes self-organize into an autonomous wireless ad hoc network. The measurement parameter data from sensing nodes is transmitted to Host System via host node and ''Cloud'' System. The implementation of multiple host nodes in Local Sensing Node Network System (LSNNS), improve risk- management of the WSNNS for real-time monitoring of landslide disaster

  8. Implementation of Multiple Host Nodes in Wireless Sensing Node Network System for Landslide Monitoring

    Science.gov (United States)

    Abas, Faizulsalihin bin; Takayama, Shigeru

    2015-02-01

    This paper proposes multiple host nodes in Wireless Sensing Node Network System (WSNNS) for landslide monitoring. As landslide disasters damage monitoring system easily, one major demand in landslide monitoring is the flexibility and robustness of the system to evaluate the current situation in the monitored area. For various reasons WSNNS can provide an important contribution to reach that aim. In this system, acceleration sensors and GPS are deployed in sensing nodes. Location information by GPS, enable the system to estimate network topology and enable the system to perceive the location in emergency by monitoring the node mode. Acceleration sensors deployment, capacitate this system to detect slow mass movement that can lead to landslide occurrence. Once deployed, sensing nodes self-organize into an autonomous wireless ad hoc network. The measurement parameter data from sensing nodes is transmitted to Host System via host node and "Cloud" System. The implementation of multiple host nodes in Local Sensing Node Network System (LSNNS), improve risk- management of the WSNNS for real-time monitoring of landslide disaster.

  9. X-43A Flight Controls

    Science.gov (United States)

    Baumann, Ethan

    2006-01-01

    A viewgraph presentation detailing X-43A Flight controls at NASA Dryden Flight Research Center is shown. The topics include: 1) NASA Dryden, Overview and current and recent flight test programs; 2) Unmanned Aerial Vehicle Synthetic Aperture Radar (UAVSAR) Program, Program Overview and Platform Precision Autopilot; and 3) Hyper-X Program, Program Overview, X-43A Flight Controls and Flight Results.

  10. Value of irradiation of neck nodes metastases. Pt. 1. Treatment of palpable nodes

    International Nuclear Information System (INIS)

    Bujko, K.

    1993-01-01

    Medical records of 222 patients with neck nodes metastases from squamous cell carcinoma of supraglottic larynx, tonsil and base of tongue were analyzed. All cases were treated with definitive irradiation. 110 patients were treated with orthovoltage technique with total doses of 5000-6000 rads, 150-10 rads per fraction; 112 patients with Co-60 with total doses 6000-7000 rads, 180-230 rads per fraction. Local-regional control was achieved in 28% of cases. Failures in the neck nodes with primary tumor controlled, were recorded in 10% of patients. Failures in a primary tumor alone were observed in 26% of patients, in primary tumor and neck nodes in 36%. Radiocurability of primary tumor and involved neck nodes was similar. In cases with primary tumor controlled, the probability of eradication of neck nodes metastases is high, even in N3 stage patients. Residual neck nodes palpable 1 to 3 months after irradiation were unfavorable prognostic factor indicated 50% risk of neck recurrence. In patients with complete regression of primary and nodal disease, failure in neck nodes was recorded in 5% of cases. The role of surgery following irradiation in patients with cervical nodes metastases is discussed. (author)

  11. Measure of Node Similarity in Multilayer Networks

    DEFF Research Database (Denmark)

    Møllgaard, Anders; Zettler, Ingo; Dammeyer, Jesper

    2016-01-01

    The weight of links in a network is often related to the similarity of thenodes. Here, we introduce a simple tunable measure for analysing the similarityof nodes across different link weights. In particular, we use the measure toanalyze homophily in a group of 659 freshman students at a large...... university.Our analysis is based on data obtained using smartphones equipped with customdata collection software, complemented by questionnaire-based data. The networkof social contacts is represented as a weighted multilayer network constructedfrom different channels of telecommunication as well as data...... might bepresent in one layer of the multilayer network and simultaneously be absent inthe other layers. For a variable such as gender, our measure reveals atransition from similarity between nodes connected with links of relatively lowweight to dis-similarity for the nodes connected by the strongest...

  12. SpicyNodes Radial Map Engine

    Science.gov (United States)

    Douma, M.; Ligierko, G.; Angelov, I.

    2008-10-01

    The need for information has increased exponentially over the past decades. The current systems for constructing, exploring, classifying, organizing, and searching information face the growing challenge of enabling their users to operate efficiently and intuitively in knowledge-heavy environments. This paper presents SpicyNodes, an advanced user interface for difficult interaction contexts. It is based on an underlying structure known as a radial map, which allows users to manipulate and interact in a natural manner with entities called nodes. This technology overcomes certain limitations of existing solutions and solves the problem of browsing complex sets of linked information. SpicyNodes is also an organic system that projects users into a living space, stimulating exploratory behavior and fostering creative thought. Our interactive radial layout is used for educational purposes and has the potential for numerous other applications.

  13. Node-based analysis of species distributions

    DEFF Research Database (Denmark)

    Borregaard, Michael Krabbe; Rahbek, Carsten; Fjeldså, Jon

    2014-01-01

    overrepresentation score (SOS) and the geographic node divergence (GND) score, which together combine ecological and evolutionary patterns into a single framework and avoids many of the problems that characterize community phylogenetic methods in current use.This approach goes through each node in the phylogeny...... with case studies on two groups with well-described biogeographical histories: a local-scale community data set of hummingbirds in the North Andes, and a large-scale data set of the distribution of all species of New World flycatchers. The node-based analysis of these two groups generates a set...... of intuitively interpretable patterns that are consistent with current biogeographical knowledge.Importantly, the results are statistically tractable, opening many possibilities for their use in analyses of evolutionary, historical and spatial patterns of species diversity. The method is implemented...

  14. [Radiotherapy in node-positive prostate cancer].

    Science.gov (United States)

    Bottke, D; Bartkowiak, D; Bolenz, C; Wiegel, T

    2016-03-01

    There are numerous randomized trials to guide the management of patients with localized (and metastatic) prostate cancer, but only a few (mostly retrospective) studies have specifically addressed node-positive patients. Therefore, there is uncertainty regarding optimal treatment in this situation. Current guidelines recommend long-term androgen deprivation therapy (ADT) alone or radiotherapy plus long-term ADT as treatment options. This overview summarizes the existing literature on the use of radiotherapy for node-positive prostate cancer as definitive treatment and as adjuvant or salvage therapy after radical prostatectomy. In this context, we also discuss several PET tracers in the imaging evaluation of patients with biochemical recurrence of prostate cancer after radical prostatectomy. As for definitive treatment, retrospective studies suggest that ADT plus radiotherapy improves overall survival compared with ADT alone. These studies also consistently demonstrated that many patients with node-positive prostate cancer can achieve long-term survival - and are likely curable - with aggressive therapy. The beneficial impact of adjuvant radiotherapy on survival in patients with pN1 prostate cancer seems to be highly influenced by tumor characteristics. Men with ≤ 2 positive lymph nodes in the presence of intermediate- to high-grade disease, or positive margins, and those with 3 or 4 positive lymph nodes are the ideal candidates for adjuvant radiotherapy (plus long-term ADT) after surgery. There is a need for randomized trials to further examine the potential role of radiotherapy as either definitive or adjuvant treatment, for patients with node-positive prostate cancer.

  15. Profound Sinoatrial Arrest Associated with Ibrutinib

    Directory of Open Access Journals (Sweden)

    Kanupriya Mathur

    2017-01-01

    Full Text Available Background. Ibrutinib is a Bruton’s tyrosine kinase (BTK inhibitor approved for second-line treatment for mantle cell lymphoma (MCL, chronic lymphocytic leukemia (CLL, and Waldenström macroglobulinemia. Ibrutinib use has been linked to increased incidence of atrial fibrillation and hypertension in multiple studies. Other forms of cardiac toxicities have also been reported in isolated case reports. Bradycardia and asystole have not been associated with ibrutinib use in the past. Case Report. We present a case of a 76-year-old female with no prior cardiac history, who initiated treatment with ibrutinib for relapsing mantle cell lymphoma and was noted to have symptomatic bradycardia, greater than 20 second long pauses on her cardiac monitor requiring placement of a permanent pacemaker. Conclusion. This is the first case associating bradycardia and asystole with tyrosine kinase inhibitor use. Irreversible inhibition of certain cardioprotective tyrosine kinases has been a growing topic of research in oncology therapeutics.

  16. Estimation of absorbed dose for poor shields under conditions of near-earth space flight

    International Nuclear Information System (INIS)

    Konyukov, V.V.; Krajnyukov, V.I.; Trufanov, A.I.

    1995-01-01

    Estimation of electron absorbed dose in materials of a space vehicle for poor shields under conditions of near-earth space flight is carried out. Impact of power and angular distribution of incidence electrons and radiation scattering processes under conditions of complex geometry and multitude of materials of flight vehicle elements and nodes is studied through simulator model by example of isolating layer of aluminium-polyethylene assembly. 3 refs.; 2 figs

  17. Towards Interactive, Incremental Programming of ROS Nodes

    DEFF Research Database (Denmark)

    Adam, Marian Sorin; Schultz, Ulrik Pagh

    Writing software for controlling robots is a complex task, usually demanding command of many programming languages and requiring significant experimentation. We believe that a bottom-up development process that complements traditional component- and MDSD-based approaches can facilitate...... experimentation. We propose the use of an internal DSL providing both a tool to interactively create ROS nodes and a behaviour-replacement mechanism to interactively reshape existing ROS nodes by wrapping the external interfaces (the publish/subscribe topics), dynamically controlled using the Python command line...

  18. Refining Nodes and Edges of State Machines

    DEFF Research Database (Denmark)

    Hallerstede, Stefan; Snook, Colin

    2011-01-01

    State machines are hierarchical automata that are widely used to structure complex behavioural specifications. We develop two notions of refinement of state machines, node refinement and edge refinement. We compare the two notions by means of examples and argue that, by adopting simple conventions...... refinement theory and UML-B state machine refinement influences the style of node refinement. Hence we propose a method with direct proof of state machine refinement avoiding the detour via Event-B that is needed by UML-B....

  19. Simultaneous dual pathology in lymph node

    Directory of Open Access Journals (Sweden)

    Prakas Kumar Mandal

    2014-05-01

    Full Text Available [Abstract] Tubercuous lymphadenitis and Non Hodgkins’ Lymphoma are common in India. As both diseases can occur in elderly persons there is a definite chance of co-existence of both diseases; but that coexistence has not been reported. Here we present a unique case in an elderly woman who had synchronous double pathology of tuberculosis (TB and Diffuse Large B cell Lymphoma (DLBCL of the lymph nodes.     Key words:- lymph nodes, tuberculosis (TB, Diffuse Large B cell Lymphoma (DLBCL.

  20. Magnetization of topological line-node semimetals

    Science.gov (United States)

    Mikitik, G. P.; Sharlai, Yu. V.

    2018-02-01

    Using an approximate expression for the Landau levels of the electrons located near a nodal line of a topological line-node semimetal, we obtain formulas for the magnetization of this semimetal at an arbitrary shape of its line. It is also shown that the dependence of the chemical potential on the magnetic field can be strong in these materials, and this dependence can essentially influence the de Haas-van Alphen oscillations. The obtained results are applied to the rhombohedral graphite, which is one of the line-node semimetals. For this material, we find temperature and magnetic field dependencies of its magnetic susceptibility.

  1. Measure of Node Similarity in Multilayer Networks

    DEFF Research Database (Denmark)

    Møllgaard, Anders; Zettler, Ingo; Dammeyer, Jesper

    2016-01-01

    university.Our analysis is based on data obtained using smartphones equipped with customdata collection software, complemented by questionnaire-based data. The networkof social contacts is represented as a weighted multilayer network constructedfrom different channels of telecommunication as well as data...... might bepresent in one layer of the multilayer network and simultaneously be absent inthe other layers. For a variable such as gender, our measure reveals atransition from similarity between nodes connected with links of relatively lowweight to dis-similarity for the nodes connected by the strongest...

  2. Initial Flight Test of the Production Support Flight Control Computers at NASA Dryden Flight Research Center

    Science.gov (United States)

    Carter, John; Stephenson, Mark

    1999-01-01

    The NASA Dryden Flight Research Center has completed the initial flight test of a modified set of F/A-18 flight control computers that gives the aircraft a research control law capability. The production support flight control computers (PSFCC) provide an increased capability for flight research in the control law, handling qualities, and flight systems areas. The PSFCC feature a research flight control processor that is "piggybacked" onto the baseline F/A-18 flight control system. This research processor allows for pilot selection of research control law operation in flight. To validate flight operation, a replication of a standard F/A-18 control law was programmed into the research processor and flight-tested over a limited envelope. This paper provides a brief description of the system, summarizes the initial flight test of the PSFCC, and describes future experiments for the PSFCC.

  3. Detection of sentinel nodes with radiopharmaceuticals

    International Nuclear Information System (INIS)

    Yokoyama, Kunihiko; Michigishi, Takatoshi; Kinuya, Seigo; Konishi, Shota; Nakajima, Kenichi; Tonami, Norihisa

    2000-01-01

    Sentinel lymph nodes have been found to be an indicator of lymph node metastasis in breast cancer. In Japan, the theory and concept of sentinel lymph nodes in breast cancer have begun to be applied to carcinomas of the digestive system. Based on clinical experience in the detection of sentinel lymph nodes with radiopharmaceuticals, differences and similarities between the radiopharmaceuticals, methods, and techniques used to detect sentinel lymph nodes have been assessed in relation to breast cancer and carcinomas of the digestive system (including carcinomas of the esophagus and large intestine). The greatest difference between the methods used for breast and digestive cancers is the site of administration of the radiopharmaceutical. In breast cancer, the radiopharmaceutical is administered into a superficial organ (i.e., the mammary gland), whereas in carcinomas of the digestive system, it is administered into a deep organ (i.e., digestive tract). Another obvious difference is in lymph flow, i.e., the flow of the mammary glands is subcutaneous whereas lymph flow in the digestive tract is submucosal. Two radionuclide diagnostic methods are available to detect sentinel lymph nodes: sentinel lymphoscintigraphy with a gamma camera and a method that involves the use of a gamma probe intraoperatively. Radiopharmaceuticals used to detect sentinel lymph nodes must be smoothly transferred from the site of administration into the lymph, and uptake by the sentinel lymph node must continue for a long time without excessive flowing to lower reaches. The optimal particle size remains a matter of controversy, and no radiopharmaceuticals appropriate for lymphoscintigraphy have ever been approved in Japan. The authors compared the pharmacokinetics of three different radiopharmaceuticals used for sentinel lymphoscintigraphy in breast cancer ( 99m Tc-labeled albumin, 99m Tc-labeled tin colloid, and 99m Tc-labeled phytic acid) and founded that the detection rate was lowest with

  4. Lymphatic drainage and sentinel node location in breast cancer

    International Nuclear Information System (INIS)

    Uren, R.F.; Howman-Giles, R.B.; Roberts, J.; Renwick, S.; Gillett, D.; Neische, F.; Ramsay-Stewart, G.

    1999-01-01

    Full text: Mammary lymphoscintigraphy using small volume (0.1-0.2 ml) peritumoral injections of 99 Tc m -antimony sulphide colloid provided a map of the lymph drainage of a breast cancer to its draining sentinel lymph nodes in 92 of 102 patients (over 90%). Non-migration of tracer is reduced by post-injection massage for 5 min but may occur especially if the lymphatics are blocked by metastases. Drainage included the axilla in 92%, internal mammary nodes in 43%, supraclavicular nodes in 12% and intramammary interval nodes in 10% of patients. One patient drained to an interpectoral node. Drainage across the centre-line of the breast occurred in 46% of patients but direct drainage to the contralateral side of the patient was not seen. Lymphatic drainage occurred to 1 node field in 52 patients, 2 node fields in 34 patients and 3 node fields in 6 patients, so that 43% of patients had multiple draining node fields. Drainage to non-axillary sites occurred in 51% of patients. In conclusion, mammary lymphoscintigraphy accurately maps sentinel node location in breast cancer. Approximately half of the patients will have sentinel nodes outside the axilla. To achieve complete lymph node staging in patients with breast cancer, it is logical to biopsy these non-axillary sentinel nodes as well as the sentinel nodes in the axilla. Failure to do so will potentially understage the node status in 50% of patients

  5. Core Flight Software

    Data.gov (United States)

    National Aeronautics and Space Administration — The AES Core Flight Software (CFS) project purpose is to analyze applicability, and evolve and extend the reusability of the CFS system originally developed by...

  6. Adaptive structures flight experiments

    Science.gov (United States)

    Martin, Maurice

    The topics are presented in viewgraph form and include the following: adaptive structures flight experiments; enhanced resolution using active vibration suppression; Advanced Controls Technology Experiment (ACTEX); ACTEX program status; ACTEX-2; ACTEX-2 program status; modular control patch; STRV-1b Cryocooler Vibration Suppression Experiment; STRV-1b program status; Precision Optical Bench Experiment (PROBE); Clementine Spacecraft Configuration; TECHSAT all-composite spacecraft; Inexpensive Structures and Materials Flight Experiment (INFLEX); and INFLEX program status.

  7. Magnesium and Space Flight

    Directory of Open Access Journals (Sweden)

    Scott M. Smith

    2015-12-01

    Full Text Available Magnesium is an essential nutrient for muscle, cardiovascular, and bone health on Earth, and during space flight. We sought to evaluate magnesium status in 43 astronauts (34 male, 9 female; 47 ± 5 years old, mean ± SD before, during, and after 4–6-month space missions. We also studied individuals participating in a ground analog of space flight (head-down-tilt bed rest; n = 27 (17 male, 10 female, 35 ± 7 years old. We evaluated serum concentration and 24-h urinary excretion of magnesium, along with estimates of tissue magnesium status from sublingual cells. Serum magnesium increased late in flight, while urinary magnesium excretion was higher over the course of 180-day space missions. Urinary magnesium increased during flight but decreased significantly at landing. Neither serum nor urinary magnesium changed during bed rest. For flight and bed rest, significant correlations existed between the area under the curve of serum and urinary magnesium and the change in total body bone mineral content. Tissue magnesium concentration was unchanged after flight and bed rest. Increased excretion of magnesium is likely partially from bone and partially from diet, but importantly, it does not come at the expense of muscle tissue stores. While further study is needed to better understand the implications of these findings for longer space exploration missions, magnesium homeostasis and tissue status seem well maintained during 4–6-month space missions.

  8. Magnesium and Space Flight

    Science.gov (United States)

    Smith, Scott M.; Zwart, Sara R.

    2015-01-01

    Magnesium is an essential nutrient for muscle, cardiovascular, and bone health on Earth, and during space flight. We sought to evaluate magnesium status in 43 astronauts (34 male, 9 female; 47 ± 5 years old, mean ± SD) before, during, and after 4–6-month space missions. We also studied individuals participating in a ground analog of space flight (head-down-tilt bed rest; n = 27 (17 male, 10 female), 35 ± 7 years old). We evaluated serum concentration and 24-h urinary excretion of magnesium, along with estimates of tissue magnesium status from sublingual cells. Serum magnesium increased late in flight, while urinary magnesium excretion was higher over the course of 180-day space missions. Urinary magnesium increased during flight but decreased significantly at landing. Neither serum nor urinary magnesium changed during bed rest. For flight and bed rest, significant correlations existed between the area under the curve of serum and urinary magnesium and the change in total body bone mineral content. Tissue magnesium concentration was unchanged after flight and bed rest. Increased excretion of magnesium is likely partially from bone and partially from diet, but importantly, it does not come at the expense of muscle tissue stores. While further study is needed to better understand the implications of these findings for longer space exploration missions, magnesium homeostasis and tissue status seem well maintained during 4–6-month space missions. PMID:26670248

  9. Measure of Node Similarity in Multilayer Networks.

    Directory of Open Access Journals (Sweden)

    Anders Mollgaard

    Full Text Available The weight of links in a network is often related to the similarity of the nodes. Here, we introduce a simple tunable measure for analysing the similarity of nodes across different link weights. In particular, we use the measure to analyze homophily in a group of 659 freshman students at a large university. Our analysis is based on data obtained using smartphones equipped with custom data collection software, complemented by questionnaire-based data. The network of social contacts is represented as a weighted multilayer network constructed from different channels of telecommunication as well as data on face-to-face contacts. We find that even strongly connected individuals are not more similar with respect to basic personality traits than randomly chosen pairs of individuals. In contrast, several socio-demographics variables have a significant degree of similarity. We further observe that similarity might be present in one layer of the multilayer network and simultaneously be absent in the other layers. For a variable such as gender, our measure reveals a transition from similarity between nodes connected with links of relatively low weight to dis-similarity for the nodes connected by the strongest links. We finally analyze the overlap between layers in the network for different levels of acquaintanceships.

  10. Network Design with Node Degree Balance Constraints

    DEFF Research Database (Denmark)

    Pedersen, Michael Berliner; Crainic, Teodor Gabriel

    This presentation discusses an extension to the network design model where there in addition to the flow conservation constraints also are constraints that require design conservation. This means that the number of arcs entering and leaving a node must be the same. As will be shown the model has ...

  11. Penile lymphoscintigraphy for sentinel node identification

    International Nuclear Information System (INIS)

    Valdes Olmos, R.A.; Hoefnagel, C.A.; Tanis, P.J.; Jansen, L.; Nieweg, O.E.; Meinhardt, W.; Horenblas, S.

    2001-01-01

    Lymphoscintigraphy for sentinel node (SN) identification has been extensively validated in breast cancer and melanoma. The aim of this study was to evaluate the findings of lymphoscintigraphy for SN identification in carcinoma of the penis. Lymphoscintigraphy was performed in 74 consecutive patients (mean age 62.2 years, range 28-87 years) with clinically lymph node-negative squamous cell carcinoma of the penis (stage T2 or greater). Following local anaesthesia by xy-locaine 10% spray, technetium-99m nanocolloid (mean dose 64.8 MBq, range 40-131 MBq) in a volume of 0.3-0.4 ml was injected intradermally around the tumour. Shortly after injection, a 20-min dynamic study was performed with a dual-head gamma camera; subsequently, static anterior and lateral images were obtained at 30 min and 2 h using simultaneous cobalt-57 flood source transmission scanning. 57 Co-assisted skin marking defined SN location for gamma probe/blue dye-guided biopsy, which was performed the next day. The SN visualization rate was 97% (72/74). Lymphatic drainage was bilateral in 81% of the cases (58/72), exclusively to the left groin in 13% (9/72) and only to the right groin in 6%. Bilateral lymph node drainage was synchronous in 38% (22/58) and asynchronous in 62% (in 18 patients the initial route was the left groin, and in the other 18, the right groin). Visualization before 30 min occurred in 66 patients (93%), in 64 of them (88%) already during the dynamic study. A total of 173 SNs were visualized (85 in the right groin, 88 in the left groin). Pitfalls were caused by inguinal skin contamination during injection (four patients) and intracavernous administration (one patient). At surgery, a total of 161 SNs were identified and removed. Sixteen patients (22%) had a tumour-positive SN and underwent standard regional lymph node dissection subsequently. During follow-up (median 28 months, range 3-74 months), two patients with a negative SN developed lymph node metastases in the mapped basin

  12. Penile lymphoscintigraphy for sentinel node identification

    Energy Technology Data Exchange (ETDEWEB)

    Valdes Olmos, R.A.; Hoefnagel, C.A. [Netherlands Cancer Inst., Amsterdam (Netherlands). Dept. of Nuclear Medicine; Tanis, P.J.; Jansen, L.; Nieweg, O.E. [Netherlands Cancer Inst., Amsterdam (Netherlands). Dept. of Surgery; Meinhardt, W.; Horenblas, S. [Netherlands Cancer Inst., Amsterdam (Netherlands). Dept. of Urology

    2001-05-01

    Lymphoscintigraphy for sentinel node (SN) identification has been extensively validated in breast cancer and melanoma. The aim of this study was to evaluate the findings of lymphoscintigraphy for SN identification in carcinoma of the penis. Lymphoscintigraphy was performed in 74 consecutive patients (mean age 62.2 years, range 28-87 years) with clinically lymph node-negative squamous cell carcinoma of the penis (stage T2 or greater). Following local anaesthesia by xy-locaine 10% spray, technetium-99m nanocolloid (mean dose 64.8 MBq, range 40-131 MBq) in a volume of 0.3-0.4 ml was injected intradermally around the tumour. Shortly after injection, a 20-min dynamic study was performed with a dual-head gamma camera; subsequently, static anterior and lateral images were obtained at 30 min and 2 h using simultaneous cobalt-57 flood source transmission scanning. {sup 57}Co-assisted skin marking defined SN location for gamma probe/blue dye-guided biopsy, which was performed the next day. The SN visualization rate was 97% (72/74). Lymphatic drainage was bilateral in 81% of the cases (58/72), exclusively to the left groin in 13% (9/72) and only to the right groin in 6%. Bilateral lymph node drainage was synchronous in 38% (22/58) and asynchronous in 62% (in 18 patients the initial route was the left groin, and in the other 18, the right groin). Visualization before 30 min occurred in 66 patients (93%), in 64 of them (88%) already during the dynamic study. A total of 173 SNs were visualized (85 in the right groin, 88 in the left groin). Pitfalls were caused by inguinal skin contamination during injection (four patients) and intracavernous administration (one patient). At surgery, a total of 161 SNs were identified and removed. Sixteen patients (22%) had a tumour-positive SN and underwent standard regional lymph node dissection subsequently. During follow-up (median 28 months, range 3-74 months), two patients with a negative SN developed lymph node metastases in the mapped

  13. Lessons Learned from the Node 1 Temperature and Humidity Control Subsystem Design

    Science.gov (United States)

    Williams, David E.

    2010-01-01

    Node 1 flew to the International Space Station (ISS) on Flight 2A during December 1998. To date the National Aeronautics and Space Administration (NASA) has learned a lot of lessons from this module based on its history of approximately two years of acceptance testing on the ground and currently its twelve years on-orbit. This paper will provide an overview of the ISS Environmental Control and Life Support (ECLS) design of the Node 1 Temperature and Humidity Control (THC) subsystem and it will document some of the lessons that have been learned to date for this subsystem and it will document some of the lessons that have been learned to date for these subsystems based on problems prelaunch, problems encountered on-orbit, and operational problems/concerns. It is hoped that documenting these lessons learned from ISS will help in preventing them in future Programs. 1

  14. Restoration of APOLLO Data by the NSSDC and PDS Lunar Data Node

    Science.gov (United States)

    Williams, David R.; Hills, H. Kent; Guinness, Edward A.; Taylor, Patrick T.; McBride, Marie J.

    2012-01-01

    The Apollo Lunar Surface Experiment Packages (ALSEPs), suites of instruments deployed by the Apollo 12. 14, 15, 16 and 17 astronauts on the lunar surface, still represent the only in-situ measurements of the Moon's environment taken over long time periods, Much of these data are housed at the National Space Science Data Center (NSSDC) at Goddard Space Flight Center but are in forms that are not readily usable, such as microfilm, hardcopy, and magnetic tapes with older, obsolete formats. The Lunar Data Node (LDN) has been formed under the auspices of the Planetary Data System (PDS) Geosciences Node to put relevant, scientifically important Apollo data into accessible digital form for use by researchers and mission planners. The LDN has prioritized the restoration of these data based on their scientific and engineering value and the level of effort required. We will report on progress made and plans for future data restorations.

  15. Mining Important Nodes in Directed Weighted Complex Networks

    Directory of Open Access Journals (Sweden)

    Yunyun Yang

    2017-01-01

    Full Text Available In complex networks, mining important nodes has been a matter of concern by scholars. In recent years, scholars have focused on mining important nodes in undirected unweighted complex networks. But most of the methods are not applicable to directed weighted complex networks. Therefore, this paper proposes a Two-Way-PageRank method based on PageRank for further discussion of mining important nodes in directed weighted complex networks. We have mainly considered the frequency of contact between nodes and the length of time of contact between nodes. We have considered the source of the nodes (in-degree and the whereabouts of the nodes (out-degree simultaneously. We have given node important performance indicators. Through numerical examples, we analyze the impact of variation of some parameters on node important performance indicators. Finally, the paper has verified the accuracy and validity of the method through empirical network data.

  16. DAST in Flight

    Science.gov (United States)

    1980-01-01

    The modified BQM-34 Firebee II drone with Aeroelastic Research Wing (ARW-1), a supercritical airfoil, during a 1980 research flight. The remotely-piloted vehicle, which was air launched from NASA's NB-52B mothership, participated in the Drones for Aerodynamic and Structural Testing (DAST) program which ran from 1977 to 1983. The DAST 1 aircraft (Serial #72-1557), pictured, crashed on 12 June 1980 after its right wing ripped off during a test flight near Cuddeback Dry Lake, California. The crash occurred on the modified drone's third free flight. These are the image contact sheets for each image resolution of the NASA Dryden Drones for Aerodynamic and Structural Testing (DAST) Photo Gallery. From 1977 to 1983, the Dryden Flight Research Center, Edwards, California, (under two different names) conducted the DAST Program as a high-risk flight experiment using a ground-controlled, pilotless aircraft. Described by NASA engineers as a 'wind tunnel in the sky,' the DAST was a specially modified Teledyne-Ryan BQM-34E/F Firebee II supersonic target drone that was flown to validate theoretical predictions under actual flight conditions in a joint project with the Langley Research Center, Hampton, Virginia. The DAST Program merged advances in electronic remote control systems with advances in airplane design. Drones (remotely controlled, missile-like vehicles initially developed to serve as gunnery targets) had been deployed successfully during the Vietnamese conflict as reconnaissance aircraft. After the war, the energy crisis of the 1970s led NASA to seek new ways to cut fuel use and improve airplane efficiency. The DAST Program's drones provided an economical, fuel-conscious method for conducting in-flight experiments from a remote ground site. DAST explored the technology required to build wing structures with less than normal stiffness. This was done because stiffness requires structural weight but ensures freedom from flutter-an uncontrolled, divergent oscillation of

  17. Sentinel node biopsy before neoadjuvant chemotherapy spares breast cancer patients axillary lymph node dissection

    NARCIS (Netherlands)

    van Rijk, Maartje C.; Nieweg, Omgo E.; Rutgers, Emiel J. T.; Oldenburg, Hester S. A.; Valdés Olmos, Renato; Hoefnagel, Cornelis A.; Kroon, Bin B. R.

    2006-01-01

    BACKGROUND: Neoadjuvant chemotherapy in breast cancer patients is a valuable method to determine the efficacy of chemotherapy and potentially downsize the primary tumor, which facilitates breast-conserving therapy. In 18 studies published about sentinel node biopsy after neoadjuvant chemotherapy,

  18. Beginning Amazon Web Services with Node.js

    CERN Document Server

    Shackelford, Adam

    2015-01-01

    Beginning Amazon Web Services with Node.js teaches any novice Node.js developer to configure, deploy, and maintain scalable small to large scale Node.js applications in Amazon Web Services. Hosting a Node.js application in a production environment usually means turning to PaaS hosting, but this approach brings problems. Deploying Node.js directly to AWS solves the problems you encounter in these situations, enabling you to cut out the middle man. You will begin with a basic RESTful web service in Node.js, using the popular Express.js framework, pre-built and ready to run in your local env

  19. Capital Flight and Economic Performance

    OpenAIRE

    Beja, Edsel Jr.

    2007-01-01

    Capital flight aggravates resource constraints and contributes to undermine long-term economic growth. Counterfactual calculations on the Philippines suggest that capital flight contributed to lower the quality of long-term economic growth. Sustained capital flight over three decades means that capital flight had a role for the Philippines to lose the opportunities to achieve economic takeoff. Unless decisive policy actions are taken up to address enduring capital flight and manage the macroe...

  20. Recent estimates of capital flight

    OpenAIRE

    Claessens, Stijn; Naude, David

    1993-01-01

    Researchers and policymakers have in recent years paid considerable attention to the phenomenon of capital flight. Researchers have focused on four questions: What concept should be used to measure capital flight? What figure for capital flight will emerge, using this measure? Can the occurrence and magnitude of capital flight be explained by certain (economic) variables? What policy changes can be useful to reverse capital flight? The authors focus strictly on presenting estimates of capital...

  1. Perseus Post-flight

    Science.gov (United States)

    1991-01-01

    Crew members check out the Perseus proof-of-concept vehicle on Rogers Dry Lake, adjacent to the Dryden Flight Research Center, Edwards, California, after a test flight in 1991. Perseus B is a remotely piloted aircraft developed as a design-performance testbed under NASA's Environmental Research Aircraft and Sensor Technology (ERAST) project. Perseus is one of several flight vehicles involved in the ERAST project. A piston engine, propeller-powered aircraft, Perseus was designed and built by Aurora Flight Sciences Corporation, Manassas, Virginia. The objectives of Perseus B's ERAST flight tests have been to reach and maintain horizontal flight above altitudes of 60,000 feet and demonstrate the capability to fly missions lasting from 8 to 24 hours, depending on payload and altitude requirements. The Perseus B aircraft established an unofficial altitude record for a single-engine, propeller-driven, remotely piloted aircraft on June 27, 1998. It reached an altitude of 60,280 feet. In 1999, several modifications were made to the Perseus aircraft including engine, avionics, and flight-control-system improvements. These improvements were evaluated in a series of operational readiness and test missions at the Dryden Flight Research Center, Edwards, California. Perseus is a high-wing monoplane with a conventional tail design. Its narrow, straight, high-aspect-ratio wing is mounted atop the fuselage. The aircraft is pusher-designed with the propeller mounted in the rear. This design allows for interchangeable scientific-instrument payloads to be placed in the forward fuselage. The design also allows for unobstructed airflow to the sensors and other devices mounted in the payload compartment. The Perseus B that underwent test and development in 1999 was the third generation of the Perseus design, which began with the Perseus Proof-Of-Concept aircraft. Perseus was initially developed as part of NASA's Small High-Altitude Science Aircraft (SHASA) program, which later evolved

  2. Eclipse takeoff and flight

    Science.gov (United States)

    1998-01-01

    This 25-second clip shows the QF-106 'Delta Dart' tethered to the USAF C-141A during takeoff and in flight. NASA Dryden Flight Research Center, Edwards, California, supported a Kelly Space and Technology, Inc. (KST)/U.S. Air Force project known as Eclipse, which demonstrated a reusable tow launch vehicle concept. The purpose of the project was to demonstrate a reusable tow launch vehicle concept that had been conceived and patented by KST. Kelly Space obtained a contract with the USAF Research Laboratory for the tow launch demonstration project under the Small Business Innovation Research (SBIR) program. The USAF SBIR contract included the modifications to turn the QF-106 into the Experimental Demonstrator #1 (EXD-01), and the C141A aircraft to incorporate the tow provisions to link the two aircraft, as well as conducting flight tests. The demonstration consisted of ground and flight tests. These tests included a Combined Systems Test of both airplanes joined by a tow rope, a towed taxi test, and six towed flights. The primary goal of the project was demonstrating the tow phase of the Eclipse concept using a scaled-down tow aircraft (C-141A) and a representative aerodynamically-shaped aircraft (QF-106A) as a launch vehicle. This was successfully accomplished. On December 20, 1997, NASA research pilot Mark Stucky flew a QF-106 on the first towed flight behind an Air Force C-141 in the joint Eclipse project with KST to demonstrate the reusable tow launch vehicle concept developed by KST. Kelly hoped to use the data from the tow tests to validate a tow-to-launch procedure for reusable space launch vehicles. Stucky flew six successful tow tests between December 1997 and February 6, 1998. On February 6, 1998, the sixth and final towed flight brought the project to a successful completion. Preliminary flight results determined that the handling qualities of the QF-106 on tow were very stable; actual flight measured values of tow rope tension were well within predictions

  3. Aerodynamics of bird flight

    Directory of Open Access Journals (Sweden)

    Dvořák Rudolf

    2016-01-01

    Full Text Available Unlike airplanes birds must have either flapping or oscillating wings (the hummingbird. Only such wings can produce both lift and thrust – two sine qua non attributes of flying.The bird wings have several possibilities how to obtain the same functions as airplane wings. All are realized by the system of flight feathers. Birds have also the capabilities of adjusting the shape of the wing according to what the immediate flight situation demands, as well as of responding almost immediately to conditions the flow environment dictates, such as wind gusts, object avoidance, target tracking, etc. In bird aerodynamics also the tail plays an important role. To fly, wings impart downward momentum to the surrounding air and obtain lift by reaction. How this is achieved under various flight situations (cruise flight, hovering, landing, etc., and what the role is of the wing-generated vortices in producing lift and thrust is discussed.The issue of studying bird flight experimentally from in vivo or in vitro experiments is also briefly discussed.

  4. Flight Planning in the Cloud

    Science.gov (United States)

    Flores, Sarah L.; Chapman, Bruce D.; Tung, Waye W.; Zheng, Yang

    2011-01-01

    This new interface will enable Principal Investigators (PIs), as well as UAVSAR (Uninhabited Aerial Vehicle Synthetic Aperture Radar) members to do their own flight planning and time estimation without having to request flight lines through the science coordinator. It uses an all-in-one Google Maps interface, a JPL hosted database, and PI flight requirements to design an airborne flight plan. The application will enable users to see their own flight plan being constructed interactively through a map interface, and then the flight planning software will generate all the files necessary for the flight. Afterward, the UAVSAR team can then complete the flight request, including calendaring and supplying requisite flight request files in the expected format for processing by NASA s airborne science program. Some of the main features of the interface include drawing flight lines on the map, nudging them, adding them to the current flight plan, and reordering them. The user can also search and select takeoff, landing, and intermediate airports. As the flight plan is constructed, all of its components are constantly being saved to the database, and the estimated flight times are updated. Another feature is the ability to import flight lines from previously saved flight plans. One of the main motivations was to make this Web application as simple and intuitive as possible, while also being dynamic and robust. This Web application can easily be extended to support other airborne instruments.

  5. Perseus in Flight

    Science.gov (United States)

    1991-01-01

    The Perseus proof-of-concept vehicle flies over Rogers Dry Lake at the Dryden Flight Research Center, Edwards, California, to test basic design concepts for the remotely-piloted, high-altitude vehicle. Perseus B is a remotely piloted aircraft developed as a design-performance testbed under NASA's Environmental Research Aircraft and Sensor Technology (ERAST) project. Perseus is one of several flight vehicles involved in the ERAST project. A piston engine, propeller-powered aircraft, Perseus was designed and built by Aurora Flight Sciences Corporation, Manassas, Virginia. The objectives of Perseus B's ERAST flight tests have been to reach and maintain horizontal flight above altitudes of 60,000 feet and demonstrate the capability to fly missions lasting from 8 to 24 hours, depending on payload and altitude requirements. The Perseus B aircraft established an unofficial altitude record for a single-engine, propeller-driven, remotely piloted aircraft on June 27, 1998. It reached an altitude of 60,280 feet. In 1999, several modifications were made to the Perseus aircraft including engine, avionics, and flight-control-system improvements. These improvements were evaluated in a series of operational readiness and test missions at the Dryden Flight Research Center, Edwards, California. Perseus is a high-wing monoplane with a conventional tail design. Its narrow, straight, high-aspect-ratio wing is mounted atop the fuselage. The aircraft is pusher-designed with the propeller mounted in the rear. This design allows for interchangeable scientific-instrument payloads to be placed in the forward fuselage. The design also allows for unobstructed airflow to the sensors and other devices mounted in the payload compartment. The Perseus B that underwent test and development in 1999 was the third generation of the Perseus design, which began with the Perseus Proof-Of-Concept aircraft. Perseus was initially developed as part of NASA's Small High-Altitude Science Aircraft (SHASA

  6. Flight calls and orientation

    DEFF Research Database (Denmark)

    Larsen, Ole Næsbye; Andersen, Bent Bach; Kropp, Wibke

    2008-01-01

    flight calls was simulated by sequential computer controlled activation of five loudspeakers placed in a linear array perpendicular to the bird's migration course. The bird responded to this stimulation by changing its migratory course in the direction of that of the ‘flying conspecifics' but after about......  In a pilot experiment a European Robin, Erithacus rubecula, expressing migratory restlessness with a stable orientation, was video filmed in the dark with an infrared camera and its directional migratory activity was recorded. The flight overhead of migrating conspecifics uttering nocturnal...... 30 minutes it drifted back to its original migration course. The results suggest that songbirds migrating alone at night can use the flight calls from conspecifics as additional cues for orientation and that they may compare this information with other cues to decide what course to keep....

  7. Node clustering for wireless sensor networks

    International Nuclear Information System (INIS)

    Bhatti, S.; Qureshi, I.A.; Memon, S.

    2012-01-01

    Recent years have witnessed considerable growth in the development and deployment of clustering methods which are not only used to maintain network resources but also increases the reliability of the WSNs (Wireless Sensor Network) and the facts manifest by the wide range of clustering solutions. Node clustering by selecting key parameters to tackle the dynamic behaviour of resource constraint WSN is a challenging issue. This paper highlights the recent progress which has been carried out pertaining to the development of clustering solutions for the WSNs. The paper presents classification of node clustering methods and their comparison based on the objectives, clustering criteria and methodology. In addition, the potential open issues which need to be considered for future work are high lighted. Keywords: Clustering, Sensor Network, Static, Dynamic

  8. Source and sink nodes in absence seizures.

    Science.gov (United States)

    Rodrigues, Abner C; Machado, Birajara S; Caboclo, Luis Otavio S F; Fujita, Andre; Baccala, Luiz A; Sameshima, Koichi

    2016-08-01

    As opposed to focal epilepsy, absence seizures do not exhibit a clear seizure onset zone or focus since its ictal activity rapidly engages both brain hemispheres. Yet recent graph theoretical analysis applied to absence seizures EEG suggests the cortical focal presence, an unexpected feature for this type of epilepsy. In this study, we explore the characteristics of absence seizure by classifying the nodes as to their source/sink natures via weighted directed graph analysis based on connectivity direction and strength estimation using information partial directed coherence (iPDC). By segmenting the EEG signals into relatively short 5-sec-long time windows we studied the evolution of coupling strengths from both sink and source nodes, and the network dynamics of absence seizures in eight patients.

  9. Primary lymph node responses to mosquito bites.

    Science.gov (United States)

    Mellink, J J; Vos, B J

    1977-03-29

    Post-auricular lymph node responses and changes in fresh weight of thymus and spleen of hamsters and mice at 4 and 8 days after primary exposure of both ears to 20 bites by the mosquito Aedes aegypti were studied quantitatively. In both hosts lymph node changes characteristic of the development of cell-mediated immune responses and those which are believed to lead to antibody production occurred, with the emphasis on the latter phenomena. No reactions of thymus and spleen were observed. The responses recorded are considered to be immunologically specific. In hamsters, but not in mice, the responses related to humoral sensitization coincided in time to a large extent with those of the cell-mediated immune processes. The stronger humoral responses in mice were probably in the first place the result of the relatively higher dosages applied.

  10. ALOFT Flight Test Report

    Science.gov (United States)

    1977-10-01

    wmmmmmmmmmmmm i ifmu.immM\\]i\\ ßinimm^mmmmviwmmiwui »vimtm twfjmmmmmmi c-f—rmSmn NWC TP 5954 ALOFT Flight Test Report by James D. Ross anrJ I.. M...responsible i"- u conducting the ALOFT Flight Test Program and made contributions to this report: J. Basden , R. ".estbrook, L. Thompson, J. Willians...REPORT DOCUMENTATION PAGE READ INSTRUCTIONS BEFORE COMPLETING FORM 7. AUTMORC«; <oss James D./Xo L. M.y&ohnson IZATION NAME AND ADDRESS Naval

  11. Interactive Graph Layout of a Million Nodes

    OpenAIRE

    Peng Mi; Maoyuan Sun; Moeti Masiane; Yong Cao; Chris North

    2016-01-01

    Sensemaking of large graphs, specifically those with millions of nodes, is a crucial task in many fields. Automatic graph layout algorithms, augmented with real-time human-in-the-loop interaction, can potentially support sensemaking of large graphs. However, designing interactive algorithms to achieve this is challenging. In this paper, we tackle the scalability problem of interactive layout of large graphs, and contribute a new GPU-based force-directed layout algorithm that exploits graph to...

  12. Sentinel lymph node concept in oral cancer

    International Nuclear Information System (INIS)

    Hasegawa, Shogo; Omura, Ken; Harada, Hiroyuki; Shimamoto, Hiroaki; Yoshida, Yoshihiko; Uekusa, Masaru; Togawa, Takashi

    2005-01-01

    The cervical lymph node (CLN) status is one of the most important prognostic factors in oral cancer. However, the main method of addressing the CLN depends on diagnostic imaging. Sentinel lymph node (SN) biopsy combined with lymphoscintigraphy may be a minimally invasive technique that samples first-echelon lymph node to predict the need for neck dissection. Focused analysis of the SN is highly accurate in identifying metastases. In this study, we investigate the possibility of identifying the SN in oral cancer and the detection of metastases in SN by HE stain, cytokeratin IHC and cytokeratin 17 reverse transcription polymerase chain reaction (RT-PCR). Twenty-four consecutive patients who had clinically negative CLN underwent SN biopsy, followed by elective neck dissection. SNs were detected by means of mapping with isotope labeling 99m Tc-phytate. All lymph nodes were examined by conventional HE staining for evaluating metastasis. In addition, each SN was cut into multiple sections for cytokeratin IHC staining and for RT-PCR for cytokeratin 17. SNs were identified in 24 (100%) of 24 patients by lymphoscintigraphy and gamma probe. One to seven SNs were identified in each patient. Both HE and immunohistochemical staining of SN identified metastasis in 7 patients (29.2%), and the expression of cytokeratin 17 by RT-PCR of SN was positive in 8 patients (34.8%). No metastases were identified using HE, cytokeratin IHC staining in non-SNs. Neck failure has not developed in 23 (95.8%) of 24 patients. The results strongly suggest the usefulness of the SN concept in oral cancer and for better assessing the status of the CLN. (author)

  13. Node-Dependence-Based Dynamic Incentive Algorithm in Opportunistic Networks

    Directory of Open Access Journals (Sweden)

    Ruiyun Yu

    2014-01-01

    Full Text Available Opportunistic networks lack end-to-end paths between source nodes and destination nodes, so the communications are mainly carried out by the “store-carry-forward” strategy. Selfish behaviors of rejecting packet relay requests will severely worsen the network performance. Incentive is an efficient way to reduce selfish behaviors and hence improves the reliability and robustness of the networks. In this paper, we propose the node-dependence-based dynamic gaming incentive (NDI algorithm, which exploits the dynamic repeated gaming to motivate nodes relaying packets for other nodes. The NDI algorithm presents a mechanism of tolerating selfish behaviors of nodes. Reward and punishment methods are also designed based on the node dependence degree. Simulation results show that the NDI algorithm is effective in increasing the delivery ratio and decreasing average latency when there are a lot of selfish nodes in the opportunistic networks.

  14. Sentinel lymph node biopsy: An audit of intraoperative assessment ...

    African Journals Online (AJOL)

    2015-07-02

    Jul 2, 2015 ... Sentinel lymph node biopsy: An audit of ... cytotechnology service ... To audit results from intraoperative assessment of sentinel lymph node ..... out, and turnaround time in gynecologic cytology quality assurance: Findings.

  15. Simplified Dynamic Analysis of Grinders Spindle Node

    Science.gov (United States)

    Demec, Peter

    2014-12-01

    The contribution deals with the simplified dynamic analysis of surface grinding machine spindle node. Dynamic analysis is based on the use of the transfer matrix method, which is essentially a matrix form of method of initial parameters. The advantage of the described method, despite the seemingly complex mathematical apparatus, is primarily, that it does not require for solve the problem of costly commercial software using finite element method. All calculations can be made for example in MS Excel, which is advantageous especially in the initial stages of constructing of spindle node for the rapid assessment of the suitability its design. After detailing the entire structure of spindle node is then also necessary to perform the refined dynamic analysis in the environment of FEM, which it requires the necessary skills and experience and it is therefore economically difficult. This work was developed within grant project KEGA No. 023TUKE-4/2012 Creation of a comprehensive educational - teaching material for the article Production technique using a combination of traditional and modern information technology and e-learning.

  16. Hybrid tracers for sentinel node biopsy

    International Nuclear Information System (INIS)

    Van Den Berg, N. S.; Kleinjan, G. I.; Valdés-Olmos, R. A.; Buckle, T.; Van Leeuwen, F. I.; Klop, W. M.; Horenblas, S.; Van Der Poel, H. G.

    2014-01-01

    Conventional sentinel node (SN) mapping is performed by injection of a radiocolloid followed by lymphoscintigraphy to identify the number and location of the primary tumor draining lymph node(s), the so-called SN(s). Over the last decade research has focused on the introduction of new imaging agents that can further aid (surgical) SN identification. Different tracers for SN mapping, with varying sizes and isotopes have been reported, most of which have proven their value in a clinical setting. A major challenge lies in transferring this diagnostic information obtained at the nuclear medicine department to the operating theatre thereby providing the surgeon with (image) guidance. Conventionally, an intraoperative injection of vital blue dye or a fluorescence dye is given to allow intraoperative optical SN identification. However, for some indications, the radiotracer-based approach remains crucial. More recently, hybrid tracers, that contain both a radioactive and fluorescent label, were introduced to allow for direct integration of pre- and intraoperative guidance technologies. Their potential is especially high when they are used in combination with new surgical imaging modalities and navigation tools. Next to a description of the known tracers for SN mapping, this review discusses the application of hybrid tracers during SN biopsy and how the introduction of these new techniques can further aid in translation of nuclear medicine information into the operating theatre.

  17. The local lymph node assay (LLNA).

    Science.gov (United States)

    Rovida, Costanza; Ryan, Cindy; Cinelli, Serena; Basketter, David; Dearman, Rebecca; Kimber, Ian

    2012-02-01

    The murine local lymph node assay (LLNA) is a widely accepted method for assessing the skin sensitization potential of chemicals. Compared with other in vivo methods in guinea pig, the LLNA offers important advantages with respect to animal welfare, including a requirement for reduced animal numbers as well as reduced pain and trauma. In addition to hazard identification, the LLNA is used for determining the relative skin sensitizing potency of contact allergens as a pivotal contribution to the risk assessment process. The LLNA is the only in vivo method that has been subjected to a formal validation process. The original LLNA protocol is based on measurement of the proliferative activity of draining lymph node cells (LNC), as determined by incorporation of radiolabeled thymidine. Several variants to the original LLNA have been developed to eliminate the use of radioactive materials. One such alternative is considered here: the LLNA:BrdU-ELISA method, which uses 5-bromo-2-deoxyuridine (BrdU) in place of radiolabeled thymidine to measure LNC proliferation in draining nodes. © 2012 by John Wiley & Sons, Inc.

  18. X-ray appearance of intrathoracic lymph nodes in lymphogranulomatosis

    International Nuclear Information System (INIS)

    Zagorodskaya, M.M.; Antonova, R.A.

    1980-01-01

    Analysis of clinico-roentgenological data obtained when examining 174 patients with lymphogranulomatosis is carried out. Roentgenological semiotics of the lesions of intrathoracic lymp nodes according to the Rouviere classification supplemented by Zhdanov has been specified. Technique of layer-by-layer examination with an account of roentgenotopography of intrathoracic lymph nodes promoting to their determination is developed. Dynamics of the lymph node changes under treatment is traced. Rarely occurring wide-spread decalcification of prevascular nodes after the radiotherapy is described

  19. Experimental studies of metastases of esophageal carcinoma to lymph nodes

    International Nuclear Information System (INIS)

    Inoue, Kazumasa

    1977-01-01

    Marked progress has been made in surgery for esophageal carcinoma, however, when compared to results of surgery for other carcinomas of the digestive tract, much research remains to be done. The author transplanted VX2 carcinoma, a transplantable tumor of the rabbit, to the esophagus in attempt to determine the mode of metastases of esophageal carcinoma to lymph nodes and also to observe the effect of chemotherapy (Bleomycin) and radiotherapy (Betatron). Carcinoma of the cervical esophagus metastasized to the cervical lymph nodes and then to the paratracheal lymph nodes. Carcinoma of the upper thoracic esophagus metastasized to the paratracheal lymph nodes and then to the cervical lymph nodes. Carcinoma of the mid-thoracic esophagus metastasized to the intrathoracic lymph nodes and then to the intraperitoneal lymph nodes. Carcinoma of the abdominal esophagus metastasized to the intraperitoneal lymph nodes and then to the intrathoracic lymph nodes. Skipping metastasis was rarely observed. Carcinoma of the thoracic esophagus with metastases of lymph nodes in the cervical or abdominal portion was considerably advanced, therefore it is considered that cleaning of the intrathoracic lymph nodes and simultaneous chemotherapy are required when such cases are encountered clinically. Irradiation resulted in regression in the size of the tumor and metastases to lymph nodes and there was a decrease in metastases to the distant lymph nodes. Effects of irradiation were similar on tumors and lymph nodes with positive metastases located within the field of irradiation. Bleomycin medication resulted in regression in the size of tumor and metastases to lymph nodes. Effects of Bleomycin medication were similar on tumors and lymph nodes with positive metastases. (auth.)

  20. Intraoperative examination of sentinel lymph nodes using scrape ...

    African Journals Online (AJOL)

    2014-08-03

    Aug 3, 2014 ... Background. In breast cancer, sentinel lymph node biopsy (SLNB) is widely used to assess the axilla when the nodes appear normal on palpation and ultrasonography. When the sentinel lymph nodes (SLNs) are negative, no further dissection is required. Surgical dissection or radiotherapy of the axilla is ...

  1. Intraoperative examination of sentinel lymph nodes using scrape ...

    African Journals Online (AJOL)

    Background. In breast cancer, sentinel lymph node biopsy (SLNB) is widely used to assess the axilla when the nodes appear normal on palpation and ultrasonography. When the sentinel lymph nodes (SLNs) are negative, no further dissection is required. Surgical dissection or radiotherapy of the axilla is indicated for ...

  2. A Longitudinal Comparison of Arm Morbidity in Stage I-II Breast Cancer Patients Treated with Sentinel Lymph Node Biopsy, Sentinel Lymph Node Biopsy Followed by Completion Lymph Node Dissection, or Axillary Lymph Node Dissection

    NARCIS (Netherlands)

    Kootstra, Jan J.; Hoekstra-Weebers, Josette E. H. M.; Rietman, Johan S.; de Vries, Jakob; Baas, Peter C.; Geertzen, Jan H. B.; Hoekstra, Harald J.

    Background. Long-term shoulder and arm function following sentinel lymph node biopsy (SLNB) may surpass that following complete axillary lymph node dissection (CLND) or axillary lymph node dissection (ALND). We objectively examined the morbidity and compared outcomes after SLNB, SLNB + CLND, and

  3. The histogenesis of lymph nodes in rat and rabbit

    NARCIS (Netherlands)

    Eikelenboom, P.; Nassy, J. J.; Post, J.; Versteeg, J. C.; Langevoort, H. L.

    1978-01-01

    The histogenesis of the popliteal lymph node in the rat and the popliteal and inguinal lymph nodes in the rabbit was examined by light microscopy. Special emphasis has been laid on the initial lymphocyte population in the lymph node anlage. In the rat on the seventeenth day of gestation lymphoid

  4. A longitudinal comparison of arm morbidity in stage I-II breast cancer patients treated with sentinel lymph node biopsy, sentinel lymph node biopsy followed by completion lymph node dissection, or axillary lymph node dissection

    NARCIS (Netherlands)

    Kootstra, Jan J.; Hoekstra-Weebers, Josette E.; Rietman, Johan Swanik; de Vries, Jakob; Baas, Peter C.; Geertzen, Jan H.B.; Hoekstra, Harald J.

    2010-01-01

    Background: Long-term shoulder and arm function following sentinel lymph node biopsy (SLNB) may surpass that following complete axillary lymph node dissection (CLND) or axillary lymph node dissection (ALND). We objectively examined the morbidity and compared outcomes after SLNB, SLNB + CLND, and

  5. Range Flight Safety Requirements

    Science.gov (United States)

    Loftin, Charles E.; Hudson, Sandra M.

    2018-01-01

    The purpose of this NASA Technical Standard is to provide the technical requirements for the NPR 8715.5, Range Flight Safety Program, in regards to protection of the public, the NASA workforce, and property as it pertains to risk analysis, Flight Safety Systems (FSS), and range flight operations. This standard is approved for use by NASA Headquarters and NASA Centers, including Component Facilities and Technical and Service Support Centers, and may be cited in contract, program, and other Agency documents as a technical requirement. This standard may also apply to the Jet Propulsion Laboratory or to other contractors, grant recipients, or parties to agreements to the extent specified or referenced in their contracts, grants, or agreements, when these organizations conduct or participate in missions that involve range flight operations as defined by NPR 8715.5.1.2.2 In this standard, all mandatory actions (i.e., requirements) are denoted by statements containing the term “shall.”1.3 TailoringTailoring of this standard for application to a specific program or project shall be formally documented as part of program or project requirements and approved by the responsible Technical Authority in accordance with NPR 8715.3, NASA General Safety Program Requirements.

  6. Weather and Flight Testing

    Science.gov (United States)

    Wiley, Scott

    2007-01-01

    This viewgraph document reviews some of the weather hazards involved with flight testing. Some of the hazards reviewed are: turbulence, icing, thunderstorms and winds and windshear. Maps, pictures, satellite pictures of the meteorological phenomena and graphs are included. Also included are pictures of damaged aircraft.

  7. Pegasus hypersonic flight research

    Science.gov (United States)

    Curry, Robert E.; Meyer, Robert R., Jr.; Budd, Gerald D.

    1992-01-01

    Hypersonic aeronautics research using the Pegasus air-launched space booster is described. Two areas are discussed in the paper: previously obtained results from Pegasus flights 1 and 2, and plans for future programs. Proposed future research includes boundary-layer transition studies on the airplane-like first stage and also use of the complete Pegasus launch system to boost a research vehicle to hypersonic speeds. Pegasus flight 1 and 2 measurements were used to evaluate the results of several analytical aerodynamic design tools applied during the development of the vehicle as well as to develop hypersonic flight-test techniques. These data indicated that the aerodynamic design approach for Pegasus was adequate and showed that acceptable margins were available. Additionally, the correlations provide insight into the capabilities of these analytical tools for more complex vehicles in which design margins may be more stringent. Near-term plans to conduct hypersonic boundary-layer transition studies are discussed. These plans involve the use of a smooth metallic glove at about the mid-span of the wing. Longer-term opportunities are proposed which identify advantages of the Pegasus launch system to boost large-scale research vehicles to the real-gas hypersonic flight regime.

  8. Flight telerobotic servicer legacy

    Science.gov (United States)

    Shattuck, Paul L.; Lowrie, James W.

    1992-11-01

    The Flight Telerobotic Servicer (FTS) was developed to enhance and provide a safe alternative to human presence in space. The first step for this system was a precursor development test flight (DTF-1) on the Space Shuttle. DTF-1 was to be a pathfinder for manned flight safety of robotic systems. The broad objectives of this mission were three-fold: flight validation of telerobotic manipulator (design, control algorithms, man/machine interfaces, safety); demonstration of dexterous manipulator capabilities on specific building block tasks; and correlation of manipulator performance in space with ground predictions. The DTF-1 system is comprised of a payload bay element (7-DOF manipulator with controllers, end-of-arm gripper and camera, telerobot body with head cameras and electronics module, task panel, and MPESS truss) and an aft flight deck element (force-reflecting hand controller, crew restraint, command and display panel and monitors). The approach used to develop the DTF-1 hardware, software and operations involved flight qualification of components from commercial, military, space, and R controller, end-of-arm tooling, force/torque transducer) and the development of the telerobotic system for space applications. The system is capable of teleoperation and autonomous control (advances state of the art); reliable (two-fault tolerance); and safe (man-rated). Benefits from the development flight included space validation of critical telerobotic technologies and resolution of significant safety issues relating to telerobotic operations in the Shuttle bay or in the vicinity of other space assets. This paper discusses the lessons learned and technology evolution that stemmed from developing and integrating a dexterous robot into a manned system, the Space Shuttle. Particular emphasis is placed on the safety and reliability requirements for a man-rated system as these are the critical factors which drive the overall system architecture. Other topics focused on include

  9. Stroke in Commercial Flights.

    Science.gov (United States)

    Álvarez-Velasco, Rodrigo; Masjuan, Jaime; DeFelipe, Alicia; Corral, Iñigo; Estévez-Fraga, Carlos; Crespo, Leticia; Alonso-Cánovas, Araceli

    2016-04-01

    Stroke on board aircraft has been reported in retrospective case series, mainly focusing on economy class stroke syndrome. Data on the actual incidence, pathogenesis, and prognosis of stroke in commercial flights are lacking. A prospective registry was designed to include all consecutive patients referred from an international airport (40 million passengers a year) to our hospital with a diagnosis of ischemic stroke or transient ischemic attack and onset of symptoms during a flight or immediately after landing. Forty-four patients (32 ischemic strokes and 12 transient ischemic attacks) were included over a 76-month period (January 2008 to April 2014). The estimated incidence of stroke was 1 stroke in 35 000 flights. Pathogeneses of stroke or transient ischemic attack were atherothrombotic in 16 (36%), economy class stroke syndrome in 8 (18%), cardioembolic in 7 (16%), arterial dissection in 4 (9%), lacunar stroke in 4 (9%), and undetermined in 5 (12%) patients. Carotid stenosis >70% was found in 12 (27%) of the patients. Overall prognosis was good, and thrombolysis was applied in 44% of the cases. The most common reason for not treating patients who had experienced stroke onset midflight was the delay in reaching the hospital. Only 1 patient with symptom onset during the flight prompted a flight diversion. We found a low incidence of stroke in the setting of air travel. Economy class stroke syndrome and arterial dissection were well represented in our sample. However, the main pathogenesis was atherothrombosis with a high proportion of patients with high carotid stenosis. © 2016 American Heart Association, Inc.

  10. The sentinel node concept in breast cancer: A commentary

    International Nuclear Information System (INIS)

    Canizales, A.L. . E-mail A.L.Canizales@qmul.ac.uk; Al-Yasi, A.; Gambhir, S.; Morris, G.; Granowska, M.; Britton, K.E.

    2004-01-01

    As there are multiple lymphatic pathways from the breast to the axilla with multiple possible choices for a cancer cell or a colloid, it appears intuitively unusual that one node is preferentially 'chosen'. The intuitive response would be that there is an equal chance for a breast cancer cell to travel by any lymphatic pathway to any axillary node at level 1. If this were true, then after a colloid injection into the peritumoural lymphatics or the periareolar lymphatic plexus, such a colloid has a similar chance to travel to any level 1 axillary node, be it an involved node or an uninvolved node. We have tried to resolve this conflict between intuition and practice. It was tested by identifying and measuring the activity of the radiolabelled colloid in the nodes removed in an axillary clearance and in the sentinel node or nodes after applying a sentinel node technique similar to that of Veronesi et al. The histology of all the nodes that were counted was analysed so that the colloid activity in each node was able to be correlated with its histology, whether it was involved with cancer or not involved. Measurements were obtained in those patients, in whom there were both involved and uninvolved nodes in the axillae. The colloid counts in cpm/g of each node were compared with the related sentinel node findings either involved with cancer or not involved. These were calculated either as the involved to uninvolved that is a 'positive' to 'negative' ratio. The results were that the activity ratio of all involved axillary nodes to uninvolved axillary nodes was about 4:1. The involved Sentinel nodes had on average over 25 times the uptake of the uninvolved Sentinel nodes. P value was <0.009 for a significant difference between colloid uptake in sentinel nodes with positive histology and those with negative histology. It is a new observation that involved axillary nodes show greater uptake of the colloid than uninvolved nodes in all patients where there are both involved

  11. Identifying Vulnerable Nodes of Complex Networks in Cascading Failures Induced by Node-Based Attacks

    Directory of Open Access Journals (Sweden)

    Shudong Li

    2013-01-01

    Full Text Available In the research on network security, distinguishing the vulnerable components of networks is very important for protecting infrastructures systems. Here, we probe how to identify the vulnerable nodes of complex networks in cascading failures, which was ignored before. Concerned with random attack (RA and highest load attack (HL on nodes, we model cascading dynamics of complex networks. Then, we introduce four kinds of weighting methods to characterize the nodes of networks including Barabási-Albert scale-free networks (SF, Watts-Strogatz small-world networks (WS, Erdos-Renyi random networks (ER, and two real-world networks. The simulations show that, for SF networks under HL attack, the nodes with small value of the fourth kind of weight are the most vulnerable and the ones with small value of the third weight are also vulnerable. Also, the real-world autonomous system with power-law distribution verifies these findings. Moreover, for WS and ER networks under both RA and HL attack, when the nodes have low tolerant ability, the ones with small value of the fourth kind of weight are more vulnerable and also the ones with high degree are easier to break down. The results give us important theoretical basis for digging the potential safety loophole and making protection strategy.

  12. Dual-Stack Single-Radio Communication Architecture for UAV Acting As a Mobile Node to Collect Data in WSNs

    Directory of Open Access Journals (Sweden)

    Ali Sayyed

    2015-09-01

    Full Text Available The use of mobile nodes to collect data in a Wireless Sensor Network (WSN has gained special attention over the last years. Some researchers explore the use of Unmanned Aerial Vehicles (UAVs as mobile node for such data-collection purposes. Analyzing these works, it is apparent that mobile nodes used in such scenarios are typically equipped with at least two different radio interfaces. The present work presents a Dual-Stack Single-Radio Communication Architecture (DSSRCA, which allows a UAV to communicate in a bidirectional manner with a WSN and a Sink node. The proposed architecture was specifically designed to support different network QoS requirements, such as best-effort and more reliable communications, attending both UAV-to-WSN and UAV-to-Sink communications needs. DSSRCA was implemented and tested on a real UAV, as detailed in this paper. This paper also includes a simulation analysis that addresses bandwidth consumption in an environmental monitoring application scenario. It includes an analysis of the data gathering rate that can be achieved considering different UAV flight speeds. Obtained results show the viability of using a single radio transmitter for collecting data from the WSN and forwarding such data to the Sink node.

  13. Dual-Stack Single-Radio Communication Architecture for UAV Acting As a Mobile Node to Collect Data in WSNs.

    Science.gov (United States)

    Sayyed, Ali; de Araújo, Gustavo Medeiros; Bodanese, João Paulo; Becker, Leandro Buss

    2015-09-16

    The use of mobile nodes to collect data in a Wireless Sensor Network (WSN) has gained special attention over the last years. Some researchers explore the use of Unmanned Aerial Vehicles (UAVs) as mobile node for such data-collection purposes. Analyzing these works, it is apparent that mobile nodes used in such scenarios are typically equipped with at least two different radio interfaces. The present work presents a Dual-Stack Single-Radio Communication Architecture (DSSRCA), which allows a UAV to communicate in a bidirectional manner with a WSN and a Sink node. The proposed architecture was specifically designed to support different network QoS requirements, such as best-effort and more reliable communications, attending both UAV-to-WSN and UAV-to-Sink communications needs. DSSRCA was implemented and tested on a real UAV, as detailed in this paper. This paper also includes a simulation analysis that addresses bandwidth consumption in an environmental monitoring application scenario. It includes an analysis of the data gathering rate that can be achieved considering different UAV flight speeds. Obtained results show the viability of using a single radio transmitter for collecting data from the WSN and forwarding such data to the Sink node.

  14. A random network based, node attraction facilitated network evolution method

    Directory of Open Access Journals (Sweden)

    WenJun Zhang

    2016-03-01

    Full Text Available In present study, I present a method of network evolution that based on random network, and facilitated by node attraction. In this method, I assume that the initial network is a random network, or a given initial network. When a node is ready to connect, it tends to link to the node already owning the most connections, which coincides with the general rule (Barabasi and Albert, 1999 of node connecting. In addition, a node may randomly disconnect a connection i.e., the addition of connections in the network is accompanied by the pruning of some connections. The dynamics of network evolution is determined of the attraction factor Lamda of nodes, the probability of node connection, the probability of node disconnection, and the expected initial connectance. The attraction factor of nodes, the probability of node connection, and the probability of node disconnection are time and node varying. Various dynamics can be achieved by adjusting these parameters. Effects of simplified parameters on network evolution are analyzed. The changes of attraction factor Lamda can reflect various effects of the node degree on connection mechanism. Even the changes of Lamda only will generate various networks from the random to the complex. Therefore, the present algorithm can be treated as a general model for network evolution. Modeling results show that to generate a power-law type of network, the likelihood of a node attracting connections is dependent upon the power function of the node's degree with a higher-order power. Matlab codes for simplified version of the method are provided.

  15. Lymph Node Micrometastases are Associated with Worse Survival in Patients with Otherwise Node-Negative Hilar Cholangiocarcinoma

    NARCIS (Netherlands)

    Mantel, Hendrik T. J.; Wiggers, Jim K.; Verheij, Joanne; Doff, Jan J.; Sieders, Egbert; van Gulik, Thomas M.; Gouw, Annette S. H.; Porte, Robert J.

    2015-01-01

    Lymph node metastases on routine histology are a strong negative predictor for survival after resection of hilar cholangiocarcinoma. Additional immunohistochemistry can detect lymph node micrometastases in patients who are otherwise node negative, but the prognostic value is unsure. The objective of

  16. Broadband Control of Topological Nodes in Electromagnetic Fields

    Science.gov (United States)

    Song, Alex Y.; Catrysse, Peter B.; Fan, Shanhui

    2018-05-01

    We study topological nodes (phase singularities) in electromagnetic wave interactions with structures. We show that, when the nodes exist, it is possible to bind certain nodes to a specific plane in the structure by a combination of mirror and time-reversal symmetry. Such binding does not rely on any resonances in the structure. As a result, the nodes persist on the plane over a wide wavelength range. As an implication of such broadband binding, we demonstrate that the topological nodes can be used for hiding of metallic objects over a broad wavelength range.

  17. Effects of node buffer and capacity on network traffic

    International Nuclear Information System (INIS)

    Ling Xiang; Ding Jian-Xun; Hu Mao-Bin

    2012-01-01

    In this paper, we study the optimization of network traffic by considering the effects of node buffer ability and capacity. Two node buffer settings are considered. The node capacity is considered to be proportional to its buffer ability. The node effects on network traffic systems are studied with the shortest path protocol and an extension of the optimal routing [Phys. Rev. E 74 046106 (2006)]. In the diagrams of flux—density relationships, it is shown that a nodes buffer ability and capacity have profound effects on the network traffic

  18. Partial axillary lymph node dissection inferior to the intercostobrachial nerves complements sentinel node biopsy in patients with clinically node-negative breast cancer.

    Science.gov (United States)

    Li, Jianyi; Jia, Shi; Zhang, Wenhai; Qiu, Fang; Zhang, Yang; Gu, Xi; Xue, Jinqi

    2015-06-30

    The practice of breast cancer diagnosis and treatment in China varies to that in western developed countries. With the unavailability of radioactive tracer technique for sentinel lymph nodes biopsy (SLNB), using blue dye alone has been the only option in China. Also, the diagnosis of breast malignant tumor in most Chinese centres heavily relies on intraoperative instant frozen histology which is normally followed by sentinel lymph nodes mapping, SLNB and the potential breast and axillary operations in one consecutive session. This practice appears to cause a high false negative rate (FNR) for SLNB. The present study aimed to investigate the impact of the current practice in China on the accuracy of SLNB, and whether partial axillary lymph node dissection (PALND), dissection of lymph nodes inferior to the intercostobrachial nerve (ICBN), was a good complementary procedure following SLNB using blue dye. 289 patients with clinically node-negative breast cancer were identified and recruited. Tumorectomy, intraoperative instant frozen histological diagnosis, SLNB using methylene blue dye, and PALND or complete axillary node dissection (ALND) were performed in one consecutive operative session. The choice of SLNB only, SLNB followed by PALND or by ALND was based on the pre-determined protocol and preoperative choice by the patient. Clinical parameters were analyzed and survival analysis was performed. 37% patients with clinically negative nodes were found nodes positive. 59 patients with positive SLN underwent ALND, including 47 patients with up to two positive nodes which were all located inferior to the ICBN. 9 patients had failed SLNB and underwent PALND. Among them, 3 (33.3%) patients were found to have one metastatic node. 149 patients showed negative SLNB but chose PALND. Among them, 30 (20.1%), 14 (9.4) and 1 (0.7%) patients were found to have one, two and three metastatic node(s), respectively. PALND detected 48 (30.4%) patients who had either failed SLNB or

  19. Retrieving Balloon Data in Flight

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA's Ultra Long Duration Balloon (ULDB) program will soon make flights lasting up to 100 days. Some flights may generate high data rates and retrieving this data...

  20. The generation of random directed networks with prescribed 1-node and 2-node degree correlations

    Energy Technology Data Exchange (ETDEWEB)

    Zamora-Lopez, Gorka; Kurths, Juergen [Institute of Physics, University of Potsdam, PO Box 601553, 14415 Potsdam (Germany); Zhou Changsong [Department of Physics, Hong Kong Baptist University, Kowloon Tong, Hong Kong (China); Zlatic, Vinko [Rudjer Boskovic Institute, PO Box 180, HR-10002 Zagreb (Croatia)

    2008-06-06

    The generation of random networks is a very common problem in complex network research. In this paper, we have studied the correlation nature of several real networks and found that, typically, a large number of links are deterministic, i.e. they cannot be randomized. This finding permits fast generation of ensembles of maximally random networks with prescribed 1-node and 2-node degree correlations. When the introduction of self-loops or multiple-links are not desired, random network generation methods typically reach blocked states. Here, a mechanism is proposed, the 'force-and-drop' method, to overcome such states. Our algorithm can be easily simplified for undirected graphs and reduced to account for any subclass of 2-node degree correlations.

  1. The generation of random directed networks with prescribed 1-node and 2-node degree correlations

    International Nuclear Information System (INIS)

    Zamora-Lopez, Gorka; Kurths, Juergen; Zhou Changsong; Zlatic, Vinko

    2008-01-01

    The generation of random networks is a very common problem in complex network research. In this paper, we have studied the correlation nature of several real networks and found that, typically, a large number of links are deterministic, i.e. they cannot be randomized. This finding permits fast generation of ensembles of maximally random networks with prescribed 1-node and 2-node degree correlations. When the introduction of self-loops or multiple-links are not desired, random network generation methods typically reach blocked states. Here, a mechanism is proposed, the 'force-and-drop' method, to overcome such states. Our algorithm can be easily simplified for undirected graphs and reduced to account for any subclass of 2-node degree correlations

  2. Bisphosphonate ISS Flight Experiment

    Science.gov (United States)

    LeBlanc, Adrian; Matsumoto, Toshio; Jones, Jeffrey; Shapiro, Jay; Lang, Thomas; Shackleford, Linda; Smith, Scott M.; Evans, Harlan; Spector, Elizabeth; Ploutz-Snyder, Robert; hide

    2014-01-01

    The bisphosphonate study is a collaborative effort between the NASA and JAXA space agencies to investigate the potential for antiresorptive drugs to mitigate bone changes associated with long-duration spaceflight. Elevated bone resorption is a hallmark of human spaceflight and bed rest (common zero-G analog). We tested whether an antiresorptive drug in combination with in-flight exercise would ameliorate bone loss and hypercalcuria during longduration spaceflight. Measurements include DXA, QCT, pQCT, and urine and blood biomarkers. We have completed analysis of 7 crewmembers treated with alendronate during flight and the immediate postflight (R+week) data collection in 5 of 10 controls without treatment. Both groups used the advanced resistive exercise device (ARED) during their missions. We previously reported the pre/postflight results of crew taking alendronate during flight (Osteoporosis Int. 24:2105-2114, 2013). The purpose of this report is to present the 12-month follow-up data in the treated astronauts and to compare these results with preliminary data from untreated crewmembers exercising with ARED (ARED control) or without ARED (Pre-ARED control). Results: the table presents DXA and QCT BMD expressed as percentage change from preflight in the control astronauts (18 Pre-ARED and the current 5 ARED-1-year data not yet available) and the 7 treated subjects. As shown previously the combination of exercise plus antiresorptive is effective in preventing bone loss during flight. Bone measures for treated subjects, 1 year after return from space remain at or near baseline values. Except in one region, the treated group maintained or gained bone 1 year after flight. Biomarker data are not currently available for either control group and therefore not presented. However, data from other studies with or without ARED show elevated bone resorption and urinary Ca excretion while bisphosphonate treated subjects show decreases during flight. Comparing the two control

  3. Sentinel lymph node biopsy is indicated for patients with thick clinically lymph node-negative melanoma.

    Science.gov (United States)

    Yamamoto, Maki; Fisher, Kate J; Wong, Joyce Y; Koscso, Jonathan M; Konstantinovic, Monique A; Govsyeyev, Nicholas; Messina, Jane L; Sarnaik, Amod A; Cruse, C Wayne; Gonzalez, Ricardo J; Sondak, Vernon K; Zager, Jonathan S

    2015-05-15

    Sentinel lymph node biopsy (SLNB) is indicated for the staging of clinically lymph node-negative melanoma of intermediate thickness, but its use is controversial in patients with thick melanoma. From 2002 to 2012, patients with melanoma measuring ≥4 mm in thickness were evaluated at a single institution. Associations between survival and clinicopathologic characteristics were explored. Of 571 patients with melanomas measuring ≥4 mm in thickness and no distant metastases, the median age was 66 years and 401 patients (70.2%) were male. The median Breslow thickness was 6.2 mm; the predominant subtype was nodular (45.4%). SLNB was performed in 412 patients (72%) whereas 46 patients (8.1%) presented with clinically lymph node-positive disease and 113 patients (20%) did not undergo SLNB. A positive SLN was found in 161 of 412 patients (39.1%). For SLNB performed at the study institution, 14 patients with a negative SLNB developed disease recurrence in the mapped lymph node basin (false-negative rate, 12.3%). The median disease-specific survival (DSS), overall survival (OS), and recurrence-free survival (RFS) for the entire cohort were 62.1 months, 42.5 months, and 21.2 months, respectively. The DSS and OS for patients with a negative SLNB were 82.4 months and 53.4 months, respectively; 41.2 months and 34.7 months, respectively, for patients with positive SLNB; and 26.8 months and 22 months, respectively, for patients with clinically lymph node-positive disease (Pthick melanoma and a negative SLNB appear to have significantly prolonged RFS, DSS, and OS compared with those with a positive SLNB. Therefore, SLNB should be considered as indicated for patients with thick, clinically lymph node-negative melanoma. © 2015 American Cancer Society.

  4. Sentinel lymph node detection in canine oncological patients

    International Nuclear Information System (INIS)

    Balogh, L.; Andocs, G.; Mathe, D.

    2002-01-01

    Sentinel lymph node detection was investigated in dogs with spontaneously occurring tumours. In this pilot study, 24 client-owned spontaneously tumorous dogs presented for sentinel lymph node detection. A multiple method was used with a nuclear medicine technique (injection of 99mT c human serum albumin colloid) with scintigraphy and intraoperative guidance, and blue dye injection. Of the 35 lymph nodes histologically demonstrated to contain metastases, 34 (97%) were found by radioguided surgery, which means that one would have been missed in the intraoperative localisation process; 31 nodes (89%) were clearly visualised in the gamma camera images; only 27 (77%) were blue-stained by vital dye; a mere 8 lymph nodes (23%) were enlarged and therefore easily detectable by palpation. Data obtained from the harmless application of the sentinel node concept are useful for the radiopharmaceutist. The sentinel lymph node concept is well applicable in the veterinary clinic. (author)

  5. Diagnostic possibilities in lymphatic node diseases

    International Nuclear Information System (INIS)

    Radeva, M.

    1994-01-01

    A brief review of lymphoscintigraphy applied in Bulgarian medical practice is presented. The most widely used radiopharmaceuticals are listed: 9 m Tc-colloid and 113 In-colloid; 67 Ga-citrate, 75 Se-methionine, 51 Cr-bleomycin, 201 Tl-chloride; monoclonal antibodies labelled with 125 I, 131 I, 111 In, 99 Tc. Some pathological changes occurring during indirect colloid lymphoscintigraphy re mentioned. Except for diagnostic purposes, lymphoscintigraphy is also used in following up the development of malignant lymphomas. A combination of indirect lymphoscintigraphy with succeeding radioimmunoscintigraphy of lymph nodes gives maximal reliable and precise data about the disease process and its distribution. 9 refs. (orig.)

  6. Functional Testing of Wireless Sensor Node Designs

    DEFF Research Database (Denmark)

    Virk, Kashif M.; Madsen, Jan

    2007-01-01

    Wireless sensor networks are networked embedded computer systems with stringent power, performance, cost and form-factor requirements along with numerous other constraints related to their pervasiveness and ubiquitousness. Therefore, only a systematic design methdology coupled with an efficient...... test approach can enable their conformance to design and deployment specifications. We discuss off-line, hierarchical, functional testing of complete wireless sensor nodes containing configurable logic through a combination of FPGA-based board test and Software-Based Self-Test (SBST) techniques...

  7. Daedalus - Last Dryden flight

    Science.gov (United States)

    1988-01-01

    The Daedalus 88, with Glenn Tremml piloting, is seen here on its last flight for the NASA Dryden Flight Research Center, Edwards, California. The Light Eagle and Daedalus human powered aircraft were testbeds for flight research conducted at Dryden between January 1987 and March 1988. These unique aircraft were designed and constructed by a group of students, professors, and alumni of the Massachusetts Institute of Technology within the context of the Daedalus project. The construction of the Light Eagle and Daedalus aircraft was funded primarily by the Anheuser Busch and United Technologies Corporations, respectively, with additional support from the Smithsonian Air and Space Museum, MIT, and a number of other sponsors. To celebrate the Greek myth of Daedalus, the man who constructed wings of wax and feathers to escape King Minos, the Daedalus project began with the goal of designing, building and testing a human-powered aircraft that could fly the mythical distance, 115 km. To achieve this goal, three aircraft were constructed. The Light Eagle was the prototype aircraft, weighing 92 pounds. On January 22, 1987, it set a closed course distance record of 59 km, which still stands. Also in January of 1987, the Light Eagle was powered by Lois McCallin to set the straight distance, the distance around a closed circuit, and the duration world records for the female division in human powered vehicles. Following this success, two more aircraft were built, the Daedalus 87 and Daedalus 88. Each aircraft weighed approximately 69 pounds. The Daedalus 88 aircraft was the ship that flew the 199 km from the Iraklion Air Force Base on Crete in the Mediterranean Sea, to the island of Santorini in 3 hours, 54 minutes. In the process, the aircraft set new records in distance and endurance for a human powered aircraft. The specific areas of flight research conducted at Dryden included characterizing the rigid body and flexible dynamics of the Light Eagle, investigating sensors for an

  8. Flight Crew Health Maintenance

    Science.gov (United States)

    Gullett, C. C.

    1970-01-01

    The health maintenance program for commercial flight crew personnel includes diet, weight control, and exercise to prevent heart disease development and disability grounding. The very high correlation between hypertension and overweight in cardiovascular diseases significantly influences the prognosis for a coronary prone individual and results in a high rejection rate of active military pilots applying for civilian jobs. In addition to physical fitness the major items stressed in pilot selection are: emotional maturity, glucose tolerance, and family health history.

  9. Flight Software Math Library

    Science.gov (United States)

    McComas, David

    2013-01-01

    The flight software (FSW) math library is a collection of reusable math components that provides typical math utilities required by spacecraft flight software. These utilities are intended to increase flight software quality reusability and maintainability by providing a set of consistent, well-documented, and tested math utilities. This library only has dependencies on ANSI C, so it is easily ported. Prior to this library, each mission typically created its own math utilities using ideas/code from previous missions. Part of the reason for this is that math libraries can be written with different strategies in areas like error handling, parameters orders, naming conventions, etc. Changing the utilities for each mission introduces risks and costs. The obvious risks and costs are that the utilities must be coded and revalidated. The hidden risks and costs arise in miscommunication between engineers. These utilities must be understood by both the flight software engineers and other subsystem engineers (primarily guidance navigation and control). The FSW math library is part of a larger goal to produce a library of reusable Guidance Navigation and Control (GN&C) FSW components. A GN&C FSW library cannot be created unless a standardized math basis is created. This library solves the standardization problem by defining a common feature set and establishing policies for the library s design. This allows the libraries to be maintained with the same strategy used in its initial development, which supports a library of reusable GN&C FSW components. The FSW math library is written for an embedded software environment in C. This places restrictions on the language features that can be used by the library. Another advantage of the FSW math library is that it can be used in the FSW as well as other environments like the GN&C analyst s simulators. This helps communication between the teams because they can use the same utilities with the same feature set and syntax.

  10. Radioastron flight operations

    Science.gov (United States)

    Altunin, V. I.; Sukhanov, K. G.; Altunin, K. R.

    1993-01-01

    Radioastron is a space-based very-long-baseline interferometry (VLBI) mission to be operational in the mid-90's. The spacecraft and space radio telescope (SRT) will be designed, manufactured, and launched by the Russians. The United States is constructing a DSN subnet to be used in conjunction with a Russian subnet for Radioastron SRT science data acquisition, phase link, and spacecraft and science payload health monitoring. Command and control will be performed from a Russian tracking facility. In addition to the flight element, the network of ground radio telescopes which will be performing co-observations with the space telescope are essential to the mission. Observatories in 39 locations around the world are expected to participate in the mission. Some aspects of the mission that have helped shaped the flight operations concept are: separate radio channels will be provided for spacecraft operations and for phase link and science data acquisition; 80-90 percent of the spacecraft operational time will be spent in an autonomous mode; and, mission scheduling must take into account not only spacecraft and science payload constraints, but tracking station and ground observatory availability as well. This paper will describe the flight operations system design for translating the Radioastron science program into spacecraft executed events. Planning for in-orbit checkout and contingency response will also be discussed.

  11. Interactive Graph Layout of a Million Nodes

    Directory of Open Access Journals (Sweden)

    Peng Mi

    2016-12-01

    Full Text Available Sensemaking of large graphs, specifically those with millions of nodes, is a crucial task in many fields. Automatic graph layout algorithms, augmented with real-time human-in-the-loop interaction, can potentially support sensemaking of large graphs. However, designing interactive algorithms to achieve this is challenging. In this paper, we tackle the scalability problem of interactive layout of large graphs, and contribute a new GPU-based force-directed layout algorithm that exploits graph topology. This algorithm can interactively layout graphs with millions of nodes, and support real-time interaction to explore alternative graph layouts. Users can directly manipulate the layout of vertices in a force-directed fashion. The complexity of traditional repulsive force computation is reduced by approximating calculations based on the hierarchical structure of multi-level clustered graphs. We evaluate the algorithm performance, and demonstrate human-in-the-loop layout in two sensemaking case studies. Moreover, we summarize lessons learned for designing interactive large graph layout algorithms on the GPU.

  12. Initiating a Human Variome Project Country Node.

    Science.gov (United States)

    AlAama, Jumana; Smith, Timothy D; Lo, Alan; Howard, Heather; Kline, Alexandria A; Lange, Matthew; Kaput, Jim; Cotton, Richard G H

    2011-05-01

    Genetic diseases are a pressing global health problem that requires comprehensive access to basic clinical and genetic data to counter. The creation of regional and international databases that can be easily accessed by clinicians and diagnostic labs will greatly improve our ability to accurately diagnose and treat patients with genetic disorders. The Human Variome Project is currently working in conjunction with human genetics societies to achieve this by establishing systems to collect every mutation reported by a diagnostic laboratory, clinic, or research laboratory in a country and store these within a national repository, or HVP Country Node. Nodes have already been initiated in Australia, Belgium, China, Egypt, Malaysia, and Kuwait. Each is examining how to systematically collect and share genetic, clinical, and biochemical information in a country-specific manner that is sensitive to local ethical and cultural issues. This article gathers cases of genetic data collection within countries and takes recommendations from the global community to develop a procedure for countries wishing to establish their own collection system as part of the Human Variome Project. We hope this may lead to standard practices to facilitate global collection of data and allow efficient use in clinical practice, research and therapy. © 2011 Wiley-Liss, Inc.

  13. Histological step sectioning of pelvic lymph nodes increases the number of identified lymph node metastases

    DEFF Research Database (Denmark)

    Engvad, Birte; Poulsen, Mads H; Staun, Pia W

    2014-01-01

    Pathological examinations of lymph nodes (LN) in prostate cancer patients are handled differently at various institutions. The objective of this study is to provide means to improve the guidelines by examining the impact of step sectioning on LN status in patients with intermediate and high...

  14. Does sentinel lymph node biopsy have a role in node- positive head ...

    African Journals Online (AJOL)

    10.1097/MOO.0b013e3283293631]. 6. Taylor RJ, Wahl RL, Sharma PK, et al. Sentinel node localization in oral cavity and oropharynx squamous cell cancer. Arch Otolaryngol Head Neck Surg. 2001;127(8):970-974. 7. Nieuwenhuis EJ, Pijpers R, ...

  15. Data driven CAN node reliability assessment for manufacturing system

    Science.gov (United States)

    Zhang, Leiming; Yuan, Yong; Lei, Yong

    2017-01-01

    The reliability of the Controller Area Network(CAN) is critical to the performance and safety of the system. However, direct bus-off time assessment tools are lacking in practice due to inaccessibility of the node information and the complexity of the node interactions upon errors. In order to measure the mean time to bus-off(MTTB) of all the nodes, a novel data driven node bus-off time assessment method for CAN network is proposed by directly using network error information. First, the corresponding network error event sequence for each node is constructed using multiple-layer network error information. Then, the generalized zero inflated Poisson process(GZIP) model is established for each node based on the error event sequence. Finally, the stochastic model is constructed to predict the MTTB of the node. The accelerated case studies with different error injection rates are conducted on a laboratory network to demonstrate the proposed method, where the network errors are generated by a computer controlled error injection system. Experiment results show that the MTTB of nodes predicted by the proposed method agree well with observations in the case studies. The proposed data driven node time to bus-off assessment method for CAN networks can successfully predict the MTTB of nodes by directly using network error event data.

  16. Fractal dimension analysis of malignant and benign endobronchial ultrasound nodes

    International Nuclear Information System (INIS)

    Fiz, José Antonio; Monte-Moreno, Enrique; Andreo, Felipe; Auteri, Santiago José; Sanz-Santos, José; Serra, Pere; Bonet, Gloria; Castellà, Eva; Manzano, Juan Ruiz

    2014-01-01

    Endobronchial ultrasonography (EBUS) has been applied as a routine procedure for the diagnostic of hiliar and mediastinal nodes. The authors assessed the relationship between the echographic appearance of mediastinal nodes, based on endobronchial ultrasound images, and the likelihood of malignancy. The images of twelve malignant and eleven benign nodes were evaluated. A previous processing method was applied to improve the quality of the images and to enhance the details. Texture and morphology parameters analyzed were: the image texture of the echographies and a fractal dimension that expressed the relationship between area and perimeter of the structures that appear in the image, and characterizes the convoluted inner structure of the hiliar and mediastinal nodes. Processed images showed that relationship between log perimeter and log area of hilar nodes was lineal (i.e. perimeter vs. area follow a power law). Fractal dimension was lower in the malignant nodes compared with non-malignant nodes (1.47(0.09), 1.53(0.10) mean(SD), Mann–Whitney U test p < 0.05)). Fractal dimension of ultrasonographic images of mediastinal nodes obtained through endobronchial ultrasound differ in malignant nodes from non-malignant. This parameter could differentiate malignat and non-malignat mediastinic and hiliar nodes

  17. Information spreading in Delay Tolerant Networks based on nodes' behaviors

    Science.gov (United States)

    Wu, Yahui; Deng, Su; Huang, Hongbin

    2014-07-01

    Information spreading in DTNs (Delay Tolerant Networks) adopts a store-carry-forward method, and nodes receive the message from others directly. However, it is hard to judge whether the information is safe in this communication mode. In this case, a node may observe other nodes' behaviors. At present, there is no theoretical model to describe the varying rule of the nodes' trusting level. In addition, due to the uncertainty of the connectivity in DTN, a node is hard to get the global state of the network. Therefore, a rational model about the node's trusting level should be a function of the node's own observing result. For example, if a node finds k nodes carrying a message, it may trust the information with probability p(k). This paper does not explore the real distribution of p(k), but instead presents a unifying theoretical framework to evaluate the performance of the information spreading in above case. This framework is an extension of the traditional SI (susceptible-infected) model, and is useful when p(k) conforms to any distribution. Simulations based on both synthetic and real motion traces show the accuracy of the framework. Finally, we explore the impact of the nodes' behaviors based on certain special distributions through numerical results.

  18. Preoperative diagnosis of lymph node metastasis in thoracic esophageal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Eguchi, Reiki; Yamada, Akiyoshi; Ueno, Keiko; Murata, Yoko [Tokyo Women`s Medical Coll. (Japan)

    1996-10-01

    From 1994 to 1995, to evaluate the utility of preoperative CT, EUS (endoscopic ultrasonography) and US in the diagnosis of lymph node metastasis in thoracic esophageal cancer, 94 patients with thoracic esophageal cancer who underwent esophagectomy were studied clinicopathologically. The sensitivity of EUS diagnosis of upper mediastinal lymph node metastasis (85%), left-sided paragastrin lymph node metastasis (73-77%), and especially lower paraesophageal lymph node metastasis (100%) were good. But due to their low-grade specificity in EUS diagnosis, their overall accuracy was not very good. On the other hand, the overall accuracy of the CT diagnosis of lymph node metastasis was fine. However, sensitivity, the most important clinical factor in the CT diagnosis of lymph node metastasis was considerably inferior to EUS. The assessment of the diagnosis of lymph node metastasis around the tracheal bifurcation and the pulmonary hilum and the left para-cardial lesion by CT or EUS was poor. It was concluded that lymph node metastasis of these area must be the pitfall in preoperative diagnosis. The average diameter of the lymph nodes and the proportion of cancerous tissue in the lymph nodes diagnosed as metastatic lymph nodes by CT was larger than that of the false negative lymph nodes. However, the lymph nodes diagnosed as true positives by EUS showed no such tendency. This must be the reason the sensitivity of the EUS diagnosis and specificity of the CT diagnosis were favorable, but the specificity of the EUS diagnosis and especially the sensitivity of the CT diagnosis were not as good. (author)

  19. Preoperative diagnosis of lymph node metastasis in thoracic esophageal cancer

    International Nuclear Information System (INIS)

    Eguchi, Reiki; Yamada, Akiyoshi; Ueno, Keiko; Murata, Yoko

    1996-01-01

    From 1994 to 1995, to evaluate the utility of preoperative CT, EUS (endoscopic ultrasonography) and US in the diagnosis of lymph node metastasis in thoracic esophageal cancer, 94 patients with thoracic esophageal cancer who underwent esophagectomy were studied clinicopathologically. The sensitivity of EUS diagnosis of upper mediastinal lymph node metastasis (85%), left-sided paragastrin lymph node metastasis (73-77%), and especially lower paraesophageal lymph node metastasis (100%) were good. But due to their low-grade specificity in EUS diagnosis, their overall accuracy was not very good. On the other hand, the overall accuracy of the CT diagnosis of lymph node metastasis was fine. However, sensitivity, the most important clinical factor in the CT diagnosis of lymph node metastasis was considerably inferior to EUS. The assessment of the diagnosis of lymph node metastasis around the tracheal bifurcation and the pulmonary hilum and the left para-cardial lesion by CT or EUS was poor. It was concluded that lymph node metastasis of these area must be the pitfall in preoperative diagnosis. The average diameter of the lymph nodes and the proportion of cancerous tissue in the lymph nodes diagnosed as metastatic lymph nodes by CT was larger than that of the false negative lymph nodes. However, the lymph nodes diagnosed as true positives by EUS showed no such tendency. This must be the reason the sensitivity of the EUS diagnosis and specificity of the CT diagnosis were favorable, but the specificity of the EUS diagnosis and especially the sensitivity of the CT diagnosis were not as good. (author)

  20. Ultrasound differentiation of benign and malignant cervical lymph nodes

    Directory of Open Access Journals (Sweden)

    Md. Mizanur Rahman

    2009-01-01

    Full Text Available This study was conducted to see whether the size (measured by maximal short axis diameter, shape (expressed in terms of ratio dividing long axis diameter of the node by short axis diameter or L/S ratio, marginal clarity (regular or irregular margin, internal echo-pattern (homogeneous hypoechoic or heterogeneous and hilar echogenicity (presence or absence of echo-genicity in hilum are good criteria for differentiating benign from malignant cervical lymph nodes using high frequency (high resolution ultrasound probe. The study was carried out from January 1998 to December 1998, among patients with enlarged cervical lymph nodes who were scanned with a high frequency (5.0 MHz curvilinear probe. Chi-Square test was done to see the statistical correlation between two groups of nodes. A p value of <0.05 was taken as significant. Out of 65 nodes studied, 26 (100% enlarged cervical nodes with short axis diameter more than 1 cm were all malignant. In contrast 31 (79.5% of 39 enlarged nodes with short axis diameter less than 1cm were benign and rest were malignant (p<0.001. Of 34 enlarged nodes with L/S ratio <2, 30 (88.2% nodes were found malignant and 4 (11.8% were benign. Among the rest 31 enlarged nodes, 27 (87.1% with L/S ratio  2 were benign while 4 (12.9% were malignant (p <0.001. Among the 39 nodes with regular margin 28 (71.8% were found benign, where as among 26 nodes with irregular margin 23 (88.5% were malignant (p <0.001. When the internal echopattern was taken in account, 32 nodes had homogeneous hypoechoic echo of which 28 (87.5% were benign and among 33 nodes with heterogeneous echopattern 30 (90.9% were malignant (p <0.001. Among the 43 enlarged nodes with presence of hilar echogenicity 31(72.1% were found benign and 22 (100% nodes with no hilar echogenicity were all malignant (p <0.001. Such findings suggest that real time high resolution ultrasound might assist in differentiation of benign and malignant enlarged cervical lymph nodes

  1. Lymphoscintigraphic Identification of Sentinel Nodes in Malignant Melanoma

    International Nuclear Information System (INIS)

    Andries, G.; Dindelegan, G.; Ciule, Larisa; Cosgarea, Rodica; Cobzac, Gh.

    2006-01-01

    Full text: The most important prognostic factor in malignant melanoma is the presence or absence of metastasis in lymph nodes. It has been demonstrated the orderly progression of different types of tumours. Sentinel lymph node identification is done lymphoscintigraphically, followed by surgical excision and morpho pathological exam. Material and methods: We studied 33 patients with malignant melanoma (age 26-84 years) divided in 2 subgroups: group A without gamma probe (18 patients) and group B with gamma probe (15 patients). The lymphoscintigraphy (LS) was performed with a totally dose of 20-30 MBq of 99mTc-nanocoloid (Amersham) injected peritumoral or pericicatriceal in 4-6 points in volume of 0,1-0,2 ml per point. Acquisition was performed dynamic for 10-15 min and static at 30-60 min p.i. on perpendicular projections. Patent blue dye was injected prior surgery. In group A has performed sentinel node excision (13 patients) or ELND (4), one patient has died before surgery. In group B sentinel nodes were surgically excised with gamma probe and ELND was performed in patients with positive lymph nodes. Histopathologically, sentinel nodes were stained with HE and in 6 cases with HMB45. Results: In group A we identified the sentinel nodes scintigraphically in all patients (median 1,83±-1,50 nodes, range 1-7). Surgically with PBD were identified 1,69±1,18 sentinel nodes, in 2 patients the SN lymphadenectomy was negative. All nodes excised were histopathologically negative, but in 4 patients loco-regional recurrence or distant metastasis developed. In group B we identified scintigraphically 33 SNs (median 2,20±1,37 nodes, range 1-5) and 4 in transit nodes in 14 patients, 24 of them being blue dye positive (80%), in 1 patient LS was negative. With gamma probe surgeon excised 39 radioactive nodes and 1 SN blue dye positive only, 10 of them being histopathologically positive (25% node metastasis). No metastasis were identified after ELND in patients with positive SNs

  2. Lymph Node Micrometastases are Associated with Worse Survival in Patients with Otherwise Node-Negative Hilar Cholangiocarcinoma.

    Science.gov (United States)

    Mantel, Hendrik T J; Wiggers, Jim K; Verheij, Joanne; Doff, Jan J; Sieders, Egbert; van Gulik, Thomas M; Gouw, Annette S H; Porte, Robert J

    2015-12-01

    Lymph node metastases on routine histology are a strong negative predictor for survival after resection of hilar cholangiocarcinoma. Additional immunohistochemistry can detect lymph node micrometastases in patients who are otherwise node negative, but the prognostic value is unsure. The objective of this study was to assess the effect on survival of immunohistochemically detected lymph node micrometastases in patients with node-negative (pN0) hilar cholangiocarcinoma on routine histology. Between 1990 and 2010, a total of 146 patients underwent curative-intent resection of hilar cholangiocarcinoma with regional lymphadenectomy at two university medical centers in the Netherlands. Ninety-one patients (62 %) without lymph node metastases at routine histology were included. Micrometastases were identified by multiple sectioning of all lymph nodes and additional immunostaining with an antibody against cytokeratin 19 (K19). The association with overall survival was assessed in univariable and multivariable analysis. Median follow-up was 48 months. Micrometastases were identified in 16 (5 %) of 324 lymph nodes, corresponding to 11 (12 %) of 91 patients. There were no differences in clinical variables between K19 lymph node-positive and -negative patients. Five-year survival rates in patients with lymph node micrometastases were significantly lower compared to patients without micrometastases (27 vs. 54 %, P = 0.01). Multivariable analysis confirmed micrometastases as an independent prognostic factor for survival (adjusted Hazard ratio 2.4, P = 0.02). Lymph node micrometastases are associated with worse survival after resection of hilar cholangiocarcinoma. Immunohistochemical detection of lymph node micrometastases leads to better staging of patients who were initially diagnosed with node-negative (pN0) hilar cholangiocarcinoma on routine histology.

  3. Flight Test of an Intelligent Flight-Control System

    Science.gov (United States)

    Davidson, Ron; Bosworth, John T.; Jacobson, Steven R.; Thomson, Michael Pl; Jorgensen, Charles C.

    2003-01-01

    The F-15 Advanced Controls Technology for Integrated Vehicles (ACTIVE) airplane (see figure) was the test bed for a flight test of an intelligent flight control system (IFCS). This IFCS utilizes a neural network to determine critical stability and control derivatives for a control law, the real-time gains of which are computed by an algorithm that solves the Riccati equation. These derivatives are also used to identify the parameters of a dynamic model of the airplane. The model is used in a model-following portion of the control law, in order to provide specific vehicle handling characteristics. The flight test of the IFCS marks the initiation of the Intelligent Flight Control System Advanced Concept Program (IFCS ACP), which is a collaboration between NASA and Boeing Phantom Works. The goals of the IFCS ACP are to (1) develop the concept of a flight-control system that uses neural-network technology to identify aircraft characteristics to provide optimal aircraft performance, (2) develop a self-training neural network to update estimates of aircraft properties in flight, and (3) demonstrate the aforementioned concepts on the F-15 ACTIVE airplane in flight. The activities of the initial IFCS ACP were divided into three Phases, each devoted to the attainment of a different objective. The objective of Phase I was to develop a pre-trained neural network to store and recall the wind-tunnel-based stability and control derivatives of the vehicle. The objective of Phase II was to develop a neural network that can learn how to adjust the stability and control derivatives to account for failures or modeling deficiencies. The objective of Phase III was to develop a flight control system that uses the neural network outputs as a basis for controlling the aircraft. The flight test of the IFCS was performed in stages. In the first stage, the Phase I version of the pre-trained neural network was flown in a passive mode. The neural network software was running using flight data

  4. Suppressing epidemics on networks by exploiting observer nodes.

    Science.gov (United States)

    Takaguchi, Taro; Hasegawa, Takehisa; Yoshida, Yuichi

    2014-07-01

    To control infection spreading on networks, we investigate the effect of observer nodes that recognize infection in a neighboring node and make the rest of the neighbor nodes immune. We numerically show that random placement of observer nodes works better on networks with clustering than on locally treelike networks, implying that our model is promising for realistic social networks. The efficiency of several heuristic schemes for observer placement is also examined for synthetic and empirical networks. In parallel with numerical simulations of epidemic dynamics, we also show that the effect of observer placement can be assessed by the size of the largest connected component of networks remaining after removing observer nodes and links between their neighboring nodes.

  5. Suppressing epidemics on networks by exploiting observer nodes

    Science.gov (United States)

    Takaguchi, Taro; Hasegawa, Takehisa; Yoshida, Yuichi

    2014-07-01

    To control infection spreading on networks, we investigate the effect of observer nodes that recognize infection in a neighboring node and make the rest of the neighbor nodes immune. We numerically show that random placement of observer nodes works better on networks with clustering than on locally treelike networks, implying that our model is promising for realistic social networks. The efficiency of several heuristic schemes for observer placement is also examined for synthetic and empirical networks. In parallel with numerical simulations of epidemic dynamics, we also show that the effect of observer placement can be assessed by the size of the largest connected component of networks remaining after removing observer nodes and links between their neighboring nodes.

  6. Research on centrality of urban transport network nodes

    Science.gov (United States)

    Wang, Kui; Fu, Xiufen

    2017-05-01

    Based on the actual data of urban transport in Guangzhou, 19,150 bus stations in Guangzhou (as of 2014) are selected as nodes. Based on the theory of complex network, the network model of Guangzhou urban transport is constructed. By analyzing the degree centrality index, betweenness centrality index and closeness centrality index of nodes in the network, the level of centrality of each node in the network is studied. From a different point of view to determine the hub node of Guangzhou urban transport network, corresponding to the city's key sites and major transfer sites. The reliability of the network is determined by the stability of some key nodes (transport hub station). The research of network node centralization can provide a theoretical basis for the rational allocation of urban transport network sites and public transport system planning.

  7. Identification of hybrid node and link communities in complex networks.

    Science.gov (United States)

    He, Dongxiao; Jin, Di; Chen, Zheng; Zhang, Weixiong

    2015-03-02

    Identifying communities in complex networks is an effective means for analyzing complex systems, with applications in diverse areas such as social science, engineering, biology and medicine. Finding communities of nodes and finding communities of links are two popular schemes for network analysis. These schemes, however, have inherent drawbacks and are inadequate to capture complex organizational structures in real networks. We introduce a new scheme and an effective approach for identifying complex mixture structures of node and link communities, called hybrid node-link communities. A central piece of our approach is a probabilistic model that accommodates node, link and hybrid node-link communities. Our extensive experiments on various real-world networks, including a large protein-protein interaction network and a large network of semantically associated words, illustrated that the scheme for hybrid communities is superior in revealing network characteristics. Moreover, the new approach outperformed the existing methods for finding node or link communities separately.

  8. Inflammatory myofibroblastic tumor of inguinal lymph nodes, simulating lymphoma

    Directory of Open Access Journals (Sweden)

    Akansha Gandhi

    2015-01-01

    Full Text Available Multiple enlarged lymph nodes in an elderly female patient can have varied etiologies as well as histologic pictures. We are presenting the case of a 53-year-old female who presented with inguinal lymphadenopathy with fever, which was clinically misconstrued as lymphoma. Cytology could not exclude a lymphoma. Histology led to the unusual diagnosis of inflammatory myofibroblastic tumor of lymph node in this case. Inflammatory myofibroblastic tumor of the lymph node is a rare, distinctive reactive proliferative pattern in the lymph node which involves proliferation of the connective tissue elements of the lymph node, admixed with lymphocytes, plasma cells, eosinophils, and histiocytes. Multiple etiologic agents have been suggested in existing literature. Despite extensive search, no definite attributable cause could be sought. It is now widely accepted that inflammatory pseudotumor of the lymph node is a non-neoplastic proliferation which has a benign clinical course and excellent prognosis after surgical resection.

  9. Identification of hybrid node and link communities in complex networks

    Science.gov (United States)

    He, Dongxiao; Jin, Di; Chen, Zheng; Zhang, Weixiong

    2015-03-01

    Identifying communities in complex networks is an effective means for analyzing complex systems, with applications in diverse areas such as social science, engineering, biology and medicine. Finding communities of nodes and finding communities of links are two popular schemes for network analysis. These schemes, however, have inherent drawbacks and are inadequate to capture complex organizational structures in real networks. We introduce a new scheme and an effective approach for identifying complex mixture structures of node and link communities, called hybrid node-link communities. A central piece of our approach is a probabilistic model that accommodates node, link and hybrid node-link communities. Our extensive experiments on various real-world networks, including a large protein-protein interaction network and a large network of semantically associated words, illustrated that the scheme for hybrid communities is superior in revealing network characteristics. Moreover, the new approach outperformed the existing methods for finding node or link communities separately.

  10. Error Control in Distributed Node Self-Localization

    Directory of Open Access Journals (Sweden)

    Ying Zhang

    2008-03-01

    Full Text Available Location information of nodes in an ad hoc sensor network is essential to many tasks such as routing, cooperative sensing, and service delivery. Distributed node self-localization is lightweight and requires little communication overhead, but often suffers from the adverse effects of error propagation. Unlike other localization papers which focus on designing elaborate localization algorithms, this paper takes a different perspective, focusing on the error propagation problem, addressing questions such as where localization error comes from and how it propagates from node to node. To prevent error from propagating and accumulating, we develop an error-control mechanism based on characterization of node uncertainties and discrimination between neighboring nodes. The error-control mechanism uses only local knowledge and is fully decentralized. Simulation results have shown that the active selection strategy significantly mitigates the effect of error propagation for both range and directional sensors. It greatly improves localization accuracy and robustness.

  11. Rocket Flight Path

    Directory of Open Access Journals (Sweden)

    Jamie Waters

    2014-09-01

    Full Text Available This project uses Newton’s Second Law of Motion, Euler’s method, basic physics, and basic calculus to model the flight path of a rocket. From this, one can find the height and velocity at any point from launch to the maximum altitude, or apogee. This can then be compared to the actual values to see if the method of estimation is a plausible. The rocket used for this project is modeled after Bullistic-1 which was launched by the Society of Aeronautics and Rocketry at the University of South Florida.

  12. Flight Mechanics Project

    Science.gov (United States)

    Steck, Daniel

    2009-01-01

    This report documents the generation of an outbound Earth to Moon transfer preliminary database consisting of four cases calculated twice a day for a 19 year period. The database was desired as the first step in order for NASA to rapidly generate Earth to Moon trajectories for the Constellation Program using the Mission Assessment Post Processor. The completed database was created running a flight trajectory and optimization program, called Copernicus, in batch mode with the use of newly created Matlab functions. The database is accurate and has high data resolution. The techniques and scripts developed to generate the trajectory information will also be directly used in generating a comprehensive database.

  13. Flight to America

    Directory of Open Access Journals (Sweden)

    Güneli Gün

    2011-01-01

    Full Text Available Güneli Gün’s memoir piece truly combines the excitement of the young traveler with the humor of the mature narrator. Born in Izmir, Turkey, she breaks her engagement to a young but conservative Turkish architect and overcomes her father’s concerns to eventually study at Hollins College, Virginia. Addressing topics such as breaking out of a traditional society, being torn between the home country and the imagined new home, and finding comfort in the arts, “Flight to America” compellingly reflects Güneli Gün’s mastery as a storyteller.

  14. Node design in optical packet switched networks

    DEFF Research Database (Denmark)

    Nord, Martin

    2006-01-01

    The thesis discusses motivation, realisation and performance of the Optical Packet Switching (OPS) network paradigm. The work includes proposals for designs and methods to efficiently use both the wavelength- and time domain for contention resolution in asynchronous operation. The project has also......S parameter. Finally, the thesis includes a proposal for a node design and associated MAC protocol for an OPS ring topology metropolitan area network with high throughput and fairness, also for unbalanced traffic....... proposed parallel designs to overcome scalability constraints and to support migration scenarios. Furthermore, it has proposed and demonstrated optical input processing schemes for hybrids networks to simultaneously support OPS and Optical Circuit Switching. Quality of Service (QoS) differentiation enables...

  15. Mapping lymphatic nodes: Role of thrombospondin

    International Nuclear Information System (INIS)

    Spana, G.S.; Liu, J.; Rao, P.S.; Thakur, M.L.

    2002-01-01

    Aim: Lymphatic (sentinel) node (SN) mapping determines the status of lymphatic basin draining a primary tumor, provides staging information of systemic spread of malignancy, and is vital in the management of breast cancer and melanoma. Thrombospondin (TSP), a matrix bound adhesive glycoprotein, promotes cell proliferation and angiogenesis. TSP receptors are expressed on lymphocytes, and on the cells of breast cancer and melanoma. We hypothesized that Tc-99m-CSVTCR, a small, soluble, and TSP specific peptide, can image SN. Method: CSVTCR was modified at the N terminus with Aba-G(D) AGG (TP1300) and labeled with Tc-99m. Female New Zealand rabbits were anesthetized and 125 μCi TP1300 was given into the plantar/palmer surface of each foot pad in the metacarpal/metatarsal region, followed by dynamic imaging for 2 hrs and quantification of Tc-99m in SN and injection site by ROI. Control rabbits received Tc-99m-O 4 - and TP1300>Tc-99mO- 4 . Tc-99m clearance from injection site was Tc-99m-O 4 >TP1300>>TSC. % ID/g in the axillary SN was greater in than the popliteal SN for all agents. For TP1300, SN to muscle Tc-99m ratios were 552 for axillary and 140 for popliteal nodes. With infiltrating tumor cells higher uptake in SN is expected. Summary: Due to high SN uptake, rapid clearance from injection site delivering low radiation dose at injection site and ease of handling, targeting TSP receptors with Tc-99m-TP1300, a soluble, receptor specific, small biomolecule for efficient imaging of SN is promising

  16. SOME ASPECTS OF THE ANATOMY OF AXILLARY LYMPH NODES

    Directory of Open Access Journals (Sweden)

    A. I. Shvedavchenko

    2009-01-01

    Full Text Available The paper concisely reviews the classifications of axillary lymph nodes (LN and considers various approaches to their formation. The authors identify the axillary lymph chain consisting of lateral, central, and apical groups of nodes through which lymph outflows into the overlying lymph collectors, as well as of subscapular and medial groups of nodes from where lymph makes its way into the auxil- lary lymph chain.

  17. A Stirling engine analysis method based upon moving gas nodes

    Science.gov (United States)

    Martini, W. R.

    1986-01-01

    A Lagrangian nodal analysis method for Stirling engines (SEs) is described, validated, and applied to a conventional SE and an isothermalized SE (with fins in the hot and cold spaces). The analysis employs a constant-mass gas node (which moves with respect to the solid nodes during each time step) instead of the fixed gas nodes of Eulerian analysis. The isothermalized SE is found to have efficiency only slightly greater than that of a conventional SE.

  18. Active sensing and its application to sensor node reconfiguration.

    Science.gov (United States)

    Lee, Sooyong

    2014-10-08

    This paper presents a perturbation/correlation-based active sensing method and its application to sensor node configuration for environment monitoring. Sensor networks are widely used as data measurement tools, especially in dangerous environments. For large scale environment monitoring, a large number of nodes is required. For optimal measurements, the placement of nodes is very important. Nonlinear spring force-based configuration is introduced. Perturbation/correlation-based estimation of the gradient is developed and it is much more robust because it does not require any differentiation. An algorithm for tuning the stiffness using the estimated gradient for node reconfiguration is presented. The performance of the proposed algorithm is discussed with simulation results.

  19. Ratios of involved nodes in early breast cancer

    International Nuclear Information System (INIS)

    Vinh-Hung, Vincent; Royce, Melanie; Verschraegen, Claire; Promish, Donald I; Cserni, Gábor; Van de Steene, Jan; Tai, Patricia; Vlastos, Georges; Voordeckers, Mia; Storme, Guy

    2004-01-01

    The number of lymph nodes found to be involved in an axillary dissection is among the most powerful prognostic factors in breast cancer, but it is confounded by the number of lymph nodes that have been examined. We investigate an idea that has surfaced recently in the literature (since 1999), namely that the proportion of node-positive lymph nodes (or a function thereof) is a much better predictor of survival than the number of excised and node-positive lymph nodes, alone or together. The data were abstracted from 83,686 cases registered in the Surveillance, Epidemiology, and End Results (SEER) program of women diagnosed with nonmetastatic T1–T2 primary breast carcinoma between 1988 and 1997, in whom axillary node dissection was performed. The end-point was death from breast cancer. Cox models based on different expressions of nodal involvement were compared using the Nagelkerke R 2 index (R 2 N ). Ratios were modeled as percentage and as log odds of involved nodes. Log odds were estimated in a way that avoids singularities (zero values) by using the empirical logistic transform. In node-negative cases both the number of nodes excised and the log odds were significant, with hazard ratios of 0.991 (95% confidence interval 0.986–0.997) and 1.150 (1.058–1.249), respectively, but without improving R 2 N . In node-positive cases the hazard ratios were 1.003–1.088 for the number of involved nodes, 0.966–1.005 for the number of excised nodes, 1.015–1.017 for the percentage, and 1.344–1.381 for the log odds. R 2 N improved from 0.067 (no nodal covariate) to 0.102 (models based on counts only) and to 0.108 (models based on ratios). Ratios are simple optimal predictors, in that they provide at least the same prognostic value as the more traditional staging based on counting of involved nodes, without replacing them with a needlessly complicated alternative. They can be viewed as a per patient standardization in which the number of involved nodes is standardized

  20. Sentinel node detection in pre-operative axillary staging.

    Science.gov (United States)

    Trifirò, Giuseppe; Viale, Giuseppe; Gentilini, Oreste; Travaini, Laura Lavinia; Paganelli, Giovanni

    2004-06-01

    The concept of sentinel lymph node biopsy in breast cancer surgery is based on the fact that the tumour drains in a logical way via the lymphatic system, from the first to upper levels. Since axillary node dissection does not improve the prognosis of patients with breast cancer, sentinel lymph node biopsy might replace complete axillary dissection for staging of the axilla in clinically N0 patients. Sentinel lymph node biopsy would represent a significant advantage as a minimally invasive procedure, considering that about 70% of patients are found to be free from metastatic disease, yet axillary node dissection can lead to significant morbidity. Subdermal or peritumoural injection of small aliquots (and very low activity) of radiotracer is preferred to intratumoural administration, and (99m)Tc-labelled colloids with most of the particles in the 100-200 nm size range would be ideal for radioguided sentinel node biopsy in breast cancer. The success rate of radioguidance in localising the sentinel lymph node in breast cancer surgery is about 97% in institutions where a high number of procedures are performed, and the success rate of lymphoscintigraphy in sentinel node detection is about 100%. The sentinel lymph node should be processed for intraoperative frozen section examination in its entirety, based on conventional histopathology and, when necessary, immune staining with anti-cytokeratin antibody. Nowadays, lymphoscintigraphy is a useful procedure in patients with different clinical evidence of breast cancer.

  1. Clinical significance of lymph node metastasis in gastric cancer

    Science.gov (United States)

    Deng, Jing-Yu; Liang, Han

    2014-01-01

    Gastric cancer, one of the most common malignancies in the world, frequently reveals lymph node, peritoneum, and liver metastases. Most of gastric cancer patients present with lymph node metastasis when they were initially diagnosed or underwent surgical resection, which results in poor prognosis. Both the depth of tumor invasion and lymph node involvement are considered as the most important prognostic predictors of gastric cancer. Although extended lymphadenectomy was not considered a survival benefit procedure and was reported to be associated with high mortality and morbidity in two randomized controlled European trials, it showed significant superiority in terms of lower locoregional recurrence and disease related deaths compared to limited lymphadenectomy in a 15-year follow-up study. Almost all clinical investigators have reached a consensus that the predictive efficiency of the number of metastatic lymph nodes is far better than the extent of lymph node metastasis for the prognosis of gastric cancer worldwide, but other nodal metastatic classifications of gastric cancer have been proposed as alternatives to the number of metastatic lymph nodes for improving the predictive efficiency for patient prognosis. It is still controversial over whether the ratio between metastatic and examined lymph nodes is superior to the number of metastatic lymph nodes in prognostic evaluation of gastric cancer. Besides, the negative lymph node count has been increasingly recognized to be an important factor significantly associated with prognosis of gastric cancer. PMID:24744586

  2. Maximizing Lifetime of Wireless Sensor Networks with Mobile Sink Nodes

    Directory of Open Access Journals (Sweden)

    Yourong Chen

    2014-01-01

    Full Text Available In order to maximize network lifetime and balance energy consumption when sink nodes can move, maximizing lifetime of wireless sensor networks with mobile sink nodes (MLMS is researched. The movement path selection method of sink nodes is proposed. Modified subtractive clustering method, k-means method, and nearest neighbor interpolation method are used to obtain the movement paths. The lifetime optimization model is established under flow constraint, energy consumption constraint, link transmission constraint, and other constraints. The model is solved from the perspective of static and mobile data gathering of sink nodes. Subgradient method is used to solve the lifetime optimization model when one sink node stays at one anchor location. Geometric method is used to evaluate the amount of gathering data when sink nodes are moving. Finally, all sensor nodes transmit data according to the optimal data transmission scheme. Sink nodes gather the data along the shortest movement paths. Simulation results show that MLMS can prolong network lifetime, balance node energy consumption, and reduce data gathering latency under appropriate parameters. Under certain conditions, it outperforms Ratio_w, TPGF, RCC, and GRND.

  3. Erasure code-based low storage blockchain node

    OpenAIRE

    Perard, Doriane; Lacan, Jérôme; Bachy, Yann; Detchart, Jonathan

    2018-01-01

    The concept of a decentralized ledger usually implies that each node of a blockchain network stores the entire blockchain. However, in the case of popular blockchains, which each weigh several hundreds of GB, the large amount of data to be stored can incite new or low-capacity nodes to run lightweight clients. Such nodes do not participate to the global storage effort and can result in a centralization of the blockchain by very few nodes, which is contrary to the basic concepts of a blockchai...

  4. Sentinel Node Biopsy in Melanoma: A Short Update

    Science.gov (United States)

    Ferrara, Gerardo; Partenzi, Antonietta; Filosa, Alessandra

    2018-01-01

    Several controversies are still ongoing about sentinel node biopsy in melanoma. It is basically a staging procedure for melanoma > 0.75 mm in thickness or for thinner melanoma in the presence of ulceration, high mitotic rate, and/or lymphovascular invasion. Complete lymph node dissection after a positive sentinel node can also allow a better locoregional disease control but seems not to prevent the development of distant metastases. The use of sentinel node biopsy in atypical Spitz tumors should be discouraged because of their peculiar biological properties. PMID:29719827

  5. Chemical shift effect predicting lymph node status in rectal cancer using high-resolution MR imaging with node-for-node matched histopathological validation

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Hongmei; Zhang, Chongda; Ye, Feng; Liu, Yuan; Zhou, Chunwu [Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Diagnostic Radiology, National Cancer Center/Cancer Hospital, ChaoYang District, Beijing (China); Zheng, Zhaoxu [Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Colorectal Oncology, National Cancer Center/Cancer Hospital, ChaoYang District, Beijing (China); Zou, Shuangmei [Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Pathology, National Cancer Center/Cancer Hospital, ChaoYang District, Beijing (China)

    2017-09-15

    To evaluate the value of the chemical shift effect (CSE) as well as other criteria for the prediction of lymph node status. Twenty-nine patients who underwent radical surgery of rectal cancers were studied with pre- and postoperative specimen MRI. Lymph nodes were harvested from transverse whole-mount specimens and compared with in vivo and ex vivo images to obtain a precise slice-for-section match. Preoperative MR characteristics including CSE, as well as other predictors, were evaluated by two readers independently between benign and metastatic nodes. A total of 255 benign and 35 metastatic nodes were obtained; 71.4% and 69.4% of benign nodes were detected with regular CSE for two readers, whereas 80.0% and 74.3% of metastatic nodes with absence of CSE. The CSE rendered areas under the ROC curve (AUC) of 0.879 and 0.845 for predicting nodal status for two readers. The criteria of nodal location, border, signal intensity and minimum distance to the rectal wall were also useful but with AUCs (0.629-0.743) lower than those of CSE. CSE is a reliable predictor for differentiating benign from metastatic nodes. Additional criteria should be taken into account when it is difficult to determine the nodal status by using only a single predictor. (orig.)

  6. Node-node correlations and transport properties in scale-free networks

    Science.gov (United States)

    Obregon, Bibiana; Guzman, Lev

    2011-03-01

    We study some transport properties of complex networks. We focus our attention on transport properties of scale-free and small-world networks and compare two types of transport: Electric and max-flow cases. In particular, we construct scale-free networks, with a given degree sequence, to estimate the distribution of conductances for different values of assortative/dissortative mixing. For the electric case we find that the distributions of conductances are affect ed by the assortative mixing of the network whereas for the max-flow case, the distributions almost do not show changes when node-node correlations are altered. Finally, we compare local and global transport in terms of the average conductance for the small-world (Watts-Strogatz) model

  7. Getting started with Twitter Flight

    CERN Document Server

    Hamshere, Tom

    2013-01-01

    Getting Started with Twitter Flight is written with the intention to educate the readers, helping them learn how to build modular powerful applications with Flight, Twitter's cutting-edge JavaScript framework.This book is for anyone with a foundation in JavaScript who wants to build web applications. Flight is quick and easy to learn, built on technologies you already understand such as the DOM, events, and jQuery.

  8. Exact asymptotic expansion for the resistance between the center node and a node on the cobweb network boundary

    Directory of Open Access Journals (Sweden)

    R. Kenna

    2014-09-01

    Full Text Available We analyze the resistance between two nodes in a cobweb network of resistors. Based on an exact expression, we derive the asymptotic expansions for the resistance between the center node and a node on the boundary of the M x N cobweb network with resistors r and s in the two spatial directions. All coefficients in this expansion are expressed through analytical functions.

  9. Subcarinal lymph node in upper lobe non-small cell lung cancer patients: is selective lymph node dissection valid?

    Science.gov (United States)

    Aokage, Keiju; Yoshida, Junji; Ishii, Genichiro; Hishida, Tomoyuki; Nishimura, Mitsuyo; Nagai, Kanji

    2010-11-01

    Little is known about selective lymph node dissection in non-small cell lung cancer (NSCLC) patients. We sought to gain insight into subcarinal node involvement for its frequency and impact on outcome to evaluate whether it is valid to omit subcarinal lymph node dissection in upper lobe NSCLC patients. We reviewed node metastases distribution according to node region, tumor location, and histology among 1099 patients with upper lobe NSCLC. We paid special attention to subcarinal metastases patients without superior mediastinal node metastases, because their pathological stages would have been underdiagnosed if subcarinal node dissection had been omitted. We also assessed the outcome and the pattern of failure among subcarinal metastases patients. To identify subcarinal node involvement predictors, we analyzed 7 clinical factors. Subcarinal node metastases were found in 20 patients and were least frequent among squamous cell carcinoma patients (0.5%). Two of them were free from superior mediastinal metastases but died of the disease at 1 month and due to an unknown cause at 18 months, respectively. Seventeen of the 20 patients developed multi-site recurrence within 37 months. The 5-year survival rate of the 20 patients with subcarinal metastases was 9.0%, which was significantly lower than 32.0% of patients with only superior mediastinal metastases. Clinical diagnosis of node metastases was significantly predictive of subcarinal metastases. Subcarinal node metastases from upper lobe NSCLC were rare and predicted an extremely poor outcome. It appears valid to omit subcarinal node dissection in upper lobe NSCLC patients, especially in clinical N0 squamous cell carcinoma patients. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  10. Selective sentinel lymph node biopsy in papillary thyroid carcinoma in patients with no preoperative evidence of lymph node metastasis.

    Science.gov (United States)

    González, Óscar; Zafon, Carles; Caubet, Enric; García-Burillo, Amparo; Serres, Xavier; Fort, José Manuel; Mesa, Jordi; Castell, Joan; Roca, Isabel; Ramón Y Cajal, Santiago; Iglesias, Carmela

    2017-10-01

    Lymphadenectomy is recommended during surgery for papillary thyroid carcinoma when there is evidence of cervical lymph node metastasis (therapeutic) or in high-risk patients (prophylactic) such as those with T3 and T4 tumors of the TNM classification. Selective sentinel lymph node biopsy may improve preoperative diagnosis of nodal metastases. To analyze the results of selective sentinel lymph node biopsy in a group of patients with papillary thyroid carcinoma and no evidence of nodal involvement before surgery. A retrospective, single-center study in patients with papillary thyroid carcinoma and no clinical evidence of lymph node involvement who underwent surgery between 2011 and 2013. The sentinel node was identified by scintigraphy. When the sentinel node was positive, the affected compartment was removed, and when sentinel node was negative, central lymph node dissection was performed. Forty-three patients, 34 females, with a mean age of 52.3 (±17) years, were enrolled. Forty-six (27%) of the 170 SNs resected from 24 (55.8%) patients were positive for metastasis. In addition, 94 (15.6%) out of the 612 lymph nodes removed in the lymphadenectomies were positive for metastases. Twelve of the 30 (40%) low risk patients (cT1N0 and cT2N0) changed their stage to pN1, whereas 12 of 13 (92%) high risk patients (cT3N0 and cT4N0) changed to pN1 stage. Selective sentinel lymph node biopsy changes the stage of more than 50% of patients from cN0 to pN1. This confirms the need for lymph node resection in T3 and T4 tumors, but reveals the presence of lymph node metastases in 40% of T1-T2 tumors. Copyright © 2017 SEEN. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Node-to-node field calibration of wireless distributed air pollution sensor network.

    Science.gov (United States)

    Kizel, Fadi; Etzion, Yael; Shafran-Nathan, Rakefet; Levy, Ilan; Fishbain, Barak; Bartonova, Alena; Broday, David M

    2018-02-01

    Low-cost air quality sensors offer high-resolution spatiotemporal measurements that can be used for air resources management and exposure estimation. Yet, such sensors require frequent calibration to provide reliable data, since even after a laboratory calibration they might not report correct values when they are deployed in the field, due to interference with other pollutants, as a result of sensitivity to environmental conditions and due to sensor aging and drift. Field calibration has been suggested as a means for overcoming these limitations, with the common strategy involving periodical collocations of the sensors at an air quality monitoring station. However, the cost and complexity involved in relocating numerous sensor nodes back and forth, and the loss of data during the repeated calibration periods make this strategy inefficient. This work examines an alternative approach, a node-to-node (N2N) calibration, where only one sensor in each chain is directly calibrated against the reference measurements and the rest of the sensors are calibrated sequentially one against the other while they are deployed and collocated in pairs. The calibration can be performed multiple times as a routine procedure. This procedure minimizes the total number of sensor relocations, and enables calibration while simultaneously collecting data at the deployment sites. We studied N2N chain calibration and the propagation of the calibration error analytically, computationally and experimentally. The in-situ N2N calibration is shown to be generic and applicable for different pollutants, sensing technologies, sensor platforms, chain lengths, and sensor order within the chain. In particular, we show that chain calibration of three nodes, each calibrated for a week, propagate calibration errors that are similar to those found in direct field calibration. Hence, N2N calibration is shown to be suitable for calibration of distributed sensor networks. Copyright © 2017 Elsevier Ltd. All

  12. Nomogram for prediction of level 2 axillary lymph node metastasis in proven level 1 node-positive breast cancer patients.

    Science.gov (United States)

    Jiang, Yanlin; Xu, Hong; Zhang, Hao; Ou, Xunyan; Xu, Zhen; Ai, Liping; Sun, Lisha; Liu, Caigang

    2017-09-22

    The current management of the axilla in level 1 node-positive breast cancer patients is axillary lymph node dissection regardless of the status of the level 2 axillary lymph nodes. The goal of this study was to develop a nomogram predicting the probability of level 2 axillary lymph node metastasis (L-2-ALNM) in patients with level 1 axillary node-positive breast cancer. We reviewed the records of 974 patients with pathology-confirmed level 1 node-positive breast cancer between 2010 and 2014 at the Liaoning Cancer Hospital and Institute. The patients were randomized 1:1 and divided into a modeling group and a validation group. Clinical and pathological features of the patients were assessed with uni- and multivariate logistic regression. A nomogram based on independent predictors for the L-2-ALNM identified by multivariate logistic regression was constructed. Independent predictors of L-2-ALNM by the multivariate logistic regression analysis included tumor size, Ki-67 status, histological grade, and number of positive level 1 axillary lymph nodes. The areas under the receiver operating characteristic curve of the modeling set and the validation set were 0.828 and 0.816, respectively. The false-negative rates of the L-2-ALNM nomogram were 1.82% and 7.41% for the predicted probability cut-off points of level 1 axillary lymph node metastasis. Patients with a low probability of L-2-ALNM could be spared level 2 axillary lymph node dissection, thereby reducing postoperative morbidity.

  13. [Anatomy and histology characteristics of lymph node in nude mice].

    Science.gov (United States)

    Sun, R; Gao, B; Guo, C B

    2017-10-18

    To compare the differences of anatomical and histological characteristics of lymph nodes between BALB/c nude mice and BALB/c mice. Firstly, twenty BALB/c nude mice and twenty BALB/c mice were dissected by using a surgical microscope. Secondly, the differences of T cells and B cells at the lymph node were compared by the expressions of CD 3 and CD 20 immunohistochemistry dyes. There were, on average, 23 nodes per mouse contained within the large lymph node assembly in the BALB/c nude mouse. The anatomical features of the lymph node distribution in the nude mice were mainly found in the neck with relatively higher density. There were two lymph nodes both in the submandible lymph nodes group and in the superficial cervical lymph nodes group (the constituent ratios were 95% and 90%, respectively) in the BALB/c nude mice, but there were four lymph nodes (the constituent ratios were 95% and 90%, respectively) in the BALB/c mice. There were significant difference between the BALB/c nude mice and the BALB/c mice. Mostly there were two lymph nodes of deep cervical lymph nodes both in the BALB/c nude mice and the BALB/c mice (the constituent ratios were 95% and 100%, respectively). There were no significant difference between the BALB/c nude mice and the BALB/c mice. We confirmed that the number of CD 3 -positive T lymphocytes in lymph nodes of the nude mice decreased greatly as compared with the BALB/c mice. Expressions of CD3 in T cells were 95% and 100% in the BALB/c nude mice and in the BALB/c mice, respectively. There were significant differences between the BALB/c nude mice and the BALB/c mice. Expressions of CD20 in B cells were 95% and 100% in the BALB/c nude mice and in the BALB/c mice, respectively. There was no significant difference between the BALB/c nude mice and BALB/c mice. The anatomical pictures of lymph node distribution in the nude mouse will be benefit to those who are interested. The anatomical features of the lymph node local higher density in neck of

  14. Disruption Tolerant Networking Flight Validation Experiment on NASA's EPOXI Mission

    Science.gov (United States)

    Wyatt, Jay; Burleigh, Scott; Jones, Ross; Torgerson, Leigh; Wissler, Steve

    2009-01-01

    In October and November of 2008, the Jet Propulsion Laboratory installed and tested essential elements of Delay/Disruption Tolerant Networking (DTN) technology on the Deep Impact spacecraft. This experiment, called Deep Impact Network Experiment (DINET), was performed in close cooperation with the EPOXI project which has responsibility for the spacecraft. During DINET some 300 images were transmitted from the JPL nodes to the spacecraft. Then they were automatically forwarded from the spacecraft back to the JPL nodes, exercising DTN's bundle origination, transmission, acquisition, dynamic route computation, congestion control, prioritization, custody transfer, and automatic retransmission procedures, both on the spacecraft and on the ground, over a period of 27 days. All transmitted bundles were successfully received, without corruption. The DINET experiment demonstrated DTN readiness for operational use in space missions. This activity was part of a larger NASA space DTN development program to mature DTN to flight readiness for a wide variety of mission types by the end of 2011. This paper describes the DTN protocols, the flight demo implementation, validation metrics which were created for the experiment, and validation results.

  15. Stirling to Flight Initiative

    Science.gov (United States)

    Hibbard, Kenneth E.; Mason, Lee S.; Ndu, Obi; Smith, Clayton; Withrow, James P.

    2016-01-01

    Flight (S2F) initiative with the objective of developing a 100-500 We Stirling generator system. Additionally, a different approach is being devised for this initiative to avoid pitfalls of the past, and apply lessons learned from the recent ASRG experience. Two key aspects of this initiative are a Stirling System Technology Maturation Effort, and a Surrogate Mission Team (SMT) intended to provide clear mission pull and requirements context. The S2F project seeks to lead directly into a DOE flight system development of a new SRG. This paper will detail the proposed S2F initiative, and provide specifics on the key efforts designed to pave a forward path for bringing Stirling technology to flight.

  16. Cibola flight experiment satellite

    Science.gov (United States)

    Davies, P.; Liddle, Doug; Paffett, John; Sweeting, Martin; Curiel, A.; Sun, Wei; Eves, Stuart

    2004-11-01

    In order to achieve an "economy of scale" with respect to payload capacity the major trend in telecommunications satellites is for larger and larger platforms. With these large platforms the level of integration between platform and payload is increasing leading to longer delivery schedules. The typical lifecycle for procurement of these large telecommunications satellites is now 3-6 years depending on the level of non-recurring engineering needed. Surrey Satellite Technology Ltd (SSTL) has designed a low-cost platform aimed at telecommunications and navigation applications. SSTL's Geostationary Minisatellite Platform (GMP) is a new entrant addressing the lower end of the market with payloads up to 250kg requiring less than 1.5 kW power. The British National Space Centre through the MOSAIC Small Satellite Initiative supported the development of GMP. The main design goals for GMP are low-cost for the complete mission including launch and operations and a platform allowing flexible payload accommodation. GMP is specifically designed to allow rapid development and deployment with schedules typically between 1 and 2 years from contract signature to flight readiness. GMP achieves these aims by a modular design where the level of integration between the platform and payload is low. The modular design decomposes the satellite into three major components - the propulsion bay, the avionics bay and the payload module. Both the propulsion and avionics bays are reusable, largely unchanged, and independent of the payload configuration. Such a design means that SSTL or a 3rd party manufacturer can manufacture the payload in parallel to the platform with integration taking place quite late in the schedule. In July 2003 SSTL signed a contract for ESA's first Galileo navigation satellite known as GSTBV2/A. The satellite is based on GMP and ESA plan to launch it into a MEO orbit late in 2005. The second flight of GMP is likely to be in 2006 carrying a geostationary payload

  17. Lymph node metastasis in maxillary sinus carcinoma

    International Nuclear Information System (INIS)

    Le, Q.-T.; Fu, Karen K.; Kaplan, Michael J.; Terris, David J.; Fee, Willard E.; Goffinet, Don R.

    2000-01-01

    Purpose: To evaluate the incidence and prognostic significance of lymph node metastasis in maxillary sinus carcinoma. Methods and Materials: We reviewed the records of 97 patients treated for maxillary sinus carcinoma with radiotherapy at Stanford University and at the University of California, San Francisco between 1959 and 1996. Fifty-eight patients had squamous cell carcinoma (SCC), 4 had adenocarcinoma (ADE), 16 had undifferentiated carcinoma (UC), and 19 had adenoid cystic carcinoma (AC). Eight patients had T2, 36 had T3, and 53 had T4 tumors according to the 1997 AJCC staging system. Eleven patients had nodal involvement at diagnosis: 9 with SCC, 1 with UC, and 1 with AC. The most common sites of nodal involvement were ipsilateral level 1 and 2 lymph nodes. Thirty-six patients were treated with definitive radiotherapy alone, and 61 received a combination of surgical and radiation treatment. Thirty-six patients had neck irradiation, 25 of whom received elective neck irradiation (ENI) for N0 necks. The median follow-up for alive patients was 78 months. Results: The median survival for all patients was 22 months (range: 2.4-356 months). The 5- and 10-year actuarial survivals were 34% and 31%, respectively. Ten patients relapsed in the neck, with a 5-year actuarial risk of nodal relapse of 12%. The 5-year risk of neck relapse was 14% for SCC, 25% for ADE, and 7% for both UC and ACC. The overall risk of nodal involvement at either diagnosis or on follow-up was 28% for SCC, 25% for ADE, 12% for UC, and 10% for AC. All patients with nodal involvement had T3-4, and none had T2 tumors. ENI effectively prevented nodal relapse in patients with SCC and N0 neck; the 5-year actuarial risk of nodal relapse was 20% for patients without ENI and 0% for those with elective neck therapy. There was no correlation between neck relapse and primary tumor control or tumor extension into areas containing a rich lymphatic network. The most common sites of nodal relapse were in the

  18. New reference trajectory optimization algorithm for a flight management system inspired in beam search

    Directory of Open Access Journals (Sweden)

    Alejandro MURRIETA-MENDOZA

    2017-08-01

    Full Text Available With the objective of reducing the flight cost and the amount of polluting emissions released in the atmosphere, a new optimization algorithm considering the climb, cruise and descent phases is presented for the reference vertical flight trajectory. The selection of the reference vertical navigation speeds and altitudes was solved as a discrete combinatory problem by means of a graph-tree passing through nodes using the beam search optimization technique. To achieve a compromise between the execution time and the algorithm’s ability to find the global optimal solution, a heuristic methodology introducing a parameter called “optimism coefficient was used in order to estimate the trajectory’s flight cost at every node. The optimal trajectory cost obtained with the developed algorithm was compared with the cost of the optimal trajectory provided by a commercial flight management system(FMS. The global optimal solution was validated against an exhaustive search algorithm(ESA, other than the proposed algorithm. The developed algorithm takes into account weather effects, step climbs during cruise and air traffic management constraints such as constant altitude segments, constant cruise Mach, and a pre-defined reference lateral navigation route. The aircraft fuel burn was computed using a numerical performance model which was created and validated using flight test experimental data.

  19. Lessons Learned from the Node 1 Atmosphere Control and Storage and Water Recovery and Management Subsystem Design

    Science.gov (United States)

    Williams, David E.

    2011-01-01

    Node 1 flew to the International Space Station (ISS) on Flight 2A during December 1998. To date the National Aeronautics and Space Administration (NASA) has learned a lot of lessons from this module based on its history of approximately two years of acceptance testing on the ground and currently its twelve years on-orbit. This paper will provide an overview of the ISS Environmental Control and Life Support (ECLS) design of the Node 1 Atmosphere Control and Storage (ACS) and Water Recovery and Management (WRM) subsystems and it will document some of the lessons that have been learned to date for these subsystems based on problems prelaunch, problems encountered on-orbit, and operational problems/concerns. It is hoped that documenting these lessons learned from ISS will help in preventing them in future Programs.

  20. The Cibola flight experiment

    Energy Technology Data Exchange (ETDEWEB)

    Caffrey, Michael Paul [Los Alamos National Laboratory; Nelson, Anthony [Los Alamos National Laboratory; Salazar, Anthony [Los Alamos National Laboratory; Roussel - Dupre, Diane [Los Alamos National Laboratory; Katko, Kim [Los Alamos National Laboratory; Palmer, Joseph [ISE-3; Robinson, Scott [Los Alamos National Laboratory; Wirthlin, Michael [BRIGHAM YOUNG UNIV; Howes, William [BRIGHAM YOUNG UNIV; Richins, Daniel [BRIGHAM YOUNG UNIV

    2009-01-01

    The Cibola Flight Experiment (CFE) is an experimental small satellite carrying a reconfigurable processing instrument developed at the Los Alamos National Laboratory that demonstrates the feasibility of using FPGA-based high-performance computing for sensor processing in the space environment. The CFE satellite was launched on March 8, 2007 in low-earth orbit and has operated extremely well since its deployment. The nine Xilinx Virtex FPGAs used in the payload have been used for several high-throughput sensor processing applications and for single-event upset (SEU) monitoring and mitigation. This paper will describe the CFE system and summarize its operational results. In addition, this paper will describe the results from several SEU detection circuits that were performed on the spacecraft.

  1. Flight plan optimization

    Science.gov (United States)

    Dharmaseelan, Anoop; Adistambha, Keyne D.

    2015-05-01

    Fuel cost accounts for 40 percent of the operating cost of an airline. Fuel cost can be minimized by planning a flight on optimized routes. The routes can be optimized by searching best connections based on the cost function defined by the airline. The most common algorithm that used to optimize route search is Dijkstra's. Dijkstra's algorithm produces a static result and the time taken for the search is relatively long. This paper experiments a new algorithm to optimize route search which combines the principle of simulated annealing and genetic algorithm. The experimental results of route search, presented are shown to be computationally fast and accurate compared with timings from generic algorithm. The new algorithm is optimal for random routing feature that is highly sought by many regional operators.

  2. On Node Replication Attack in Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Mumtaz Qabulio

    2016-04-01

    Full Text Available WSNs (Wireless Sensor Networks comprise a large number of small, inexpensive, low power and memory constrained sensing devices (called sensor nodes that are densely deployed to measure a given physical phenomenon. Since WSNs are commonly deployed in a hostile and unattended environment, it is easy for an adversary to physically capture one or more legitimate sensor nodes, re-program and redeploy them in the network. As a result, the adversary becomes able to deploy several identical copies of physically captured nodes in the network in order to perform illegitimate activities. This type of attack is referred to as Node Replication Attack or Clone Node Attack. By launching node replication attack, an adversary can easily get control on the network which consequently is the biggest threat to confidentiality, integrity and availability of data and services. Thus, detection and prevention of node replication attack in WSNs has become an active area of research and to date more than two dozen schemes have been proposed, which address this issue. In this paper, we present a comprehensive review, classification and comparative analysis of twenty five of these schemes which help to detect and/or prevent node replication attack in WSNs

  3. Wireless Sensor Networks - Node Localization for Various Industry Problems

    International Nuclear Information System (INIS)

    Derr, Kurt; Manic, Milos

    2015-01-01

    Fast, effective monitoring following airborne releases of toxic substances is critical to mitigate risks to threatened population areas. Wireless sensor nodes at fixed predetermined locations may monitor such airborne releases and provide early warnings to the public. A challenging algorithmic problem is determining the locations to place these sensor nodes while meeting several criteria: 1) provide complete coverage of the domain, and 2) create a topology with problem dependent node densities, while 3) minimizing the number of sensor nodes. This manuscript presents a novel approach to determining optimal sensor placement, Advancing Front mEsh generation with Constrained dElaunay Triangulation and Smoothing (AFECETS) that addresses these criteria. A unique aspect of AFECETS is the ability to determine wireless sensor node locations for areas of high interest (hospitals, schools, high population density areas) that require higher density of nodes for monitoring environmental conditions, a feature that is difficult to find in other research work. The AFECETS algorithm was tested on several arbitrary shaped domains. AFECETS simulation results show that the algorithm 1) provides significant reduction in the number of nodes, in some cases over 40%, compared to an advancing front mesh generation algorithm, 2) maintains and improves optimal spacing between nodes, and 3) produces simulation run times suitable for real-time applications

  4. On node replication attack in wireless sensor networks

    International Nuclear Information System (INIS)

    Qabulio, M.; Malkani, Y.A.

    2015-01-01

    WSNs (Wireless Sensor Networks) comprise a large number of small, inexpensive, low power and memory constrained sensing devices (called sensor nodes) that are densely deployed to measure a given physical phenomenon. Since WSNs are commonly deployed in a hostile and unattended environment, it is easy for an adversary to physically capture one or more legitimate sensor nodes, re-program and redeploy them in the network. As a result, the adversary becomes able to deploy several identical copies of physically captured nodes in the network in order to perform illegitimate activities. This type of attack is referred to as Node Replication Attack or Clone Node Attack. By launching node replication attack, an adversary can easily get control on the network which consequently is the biggest threat to confidentiality, integrity and availability of data and services. Thus, detection and prevention of node replication attack in WSNs has become an active area of research and to date more than two dozen schemes have been proposed, which address this issue. In this paper, we present a comprehensive review, classification and comparative analysis of twenty five of these schemes which help to detect and/or prevent node replication attack in WSNs. (author)

  5. Developmental features of porcine haemal nodes: a histological ...

    African Journals Online (AJOL)

    The result demonstrated progressive changes in the structure of porcine haemal nodes. The capsule and trabeculae of piglet haemal nodes exhibited dense irregular connective tissues with reticular cells and smooth muscle cells. The cortex was more central while the medulla was peripheral with poorly defined boundaries ...

  6. Long range node-strut analysis of trabecular bone microarchitecture

    DEFF Research Database (Denmark)

    Schmah, Tanya; Marwan, Norbert; Thomsen, Jesper Skovhus

    2011-01-01

    PURPOSE: We present a new morphometric measure of trabecular bone microarchitecture, called mean node strength (NdStr), which is part of a newly developed approach called long range node-strut analysis. Our general aim is to describe and quantify the apparent "latticelike" microarchitecture of th...

  7. Analysis of the movement of calcified lymph nodes during breathing

    International Nuclear Information System (INIS)

    Jenkins, Peter; Salmon, Clare; Mannion, Cathy

    2005-01-01

    Purpose: To identify and measure the respiratory-induced movement of calcified mediastinal lymph nodes. Methods and materials: Twenty-one patients receiving radiation therapy for primary lung or pleural tumors were noted to have calcification within one or more mediastinal lymph nodes. The breathing motion of 27 such nodes was measured with orthogonal fluoroscopic imaging during quiet respiration. Results: All 27 nodes showed some motion synchronous with breathing. The mean respiratory movement was 6.6 mm, 2.6 mm, and 1.4 mm in the craniocaudal, dorsoventral, and mediolateral planes, respectively. There was a significant difference in the amplitude of motion in the craniocaudal plane compared with movement in the other two directions (p < 0.001). No differences were seen in the movement of lymph nodes dependent on position within the mediastinum (supracarinal vs. infracarinal or hilar vs. mediastinal). Neither size of the primary tumor nor spirometric parameters were correlated with the amplitude of lymph node movement. Conclusions: Mediastinal lymph nodes move during breathing, and this needs to be accounted for when the internal margin component of the PTV is defined. The amplitude of this movement is anisotropic and seems to be less than that reported for primary lung tumors. This should permit a modest reduction in the margin allowed for breathing movement around involved mediastinal nodes, particularly in the mediolateral and dorsoventral planes

  8. Building scalable apps with Redis and Node.js

    CERN Document Server

    Johanan, Joshua

    2014-01-01

    If the phrase scalability sounds alien to you, then this is an ideal book for you. You will not need much Node.js experience as each framework is demonstrated in a way that requires no previous knowledge of the framework. You will be building scalable Node.js applications in no time! Knowledge of JavaScript is required.

  9. The Nodal Location of Metastases in Melanoma Sentinel Lymph Nodes

    DEFF Research Database (Denmark)

    Riber-Hansen, Rikke; Nyengaard, Jens; Hamilton-Dutoit, Stephen

    2009-01-01

    BACKGROUND: The design of melanoma sentinel lymph node (SLN) histologic protocols is based on the premise that most metastases are found in the central parts of the nodes, but the evidence for this belief has never been thoroughly tested. METHODS: The nodal location of melanoma metastases in 149...

  10. Sentinel lymph node biopsy in breast cancer and melanoma

    NARCIS (Netherlands)

    Doting, Meintje Hylkje Edwina

    2007-01-01

    Summary and conclusions In the introduction, a short overview of the development of the sentinel lymph node biopsy concept is presented. In addition to melanoma and breast cancer, the usefulness of sentinel lymph node biopsy as a surgical assessment method for squamous cell carcinoma of penis and

  11. Hybrid single node genetic programming for symbolic regression

    NARCIS (Netherlands)

    Kubalìk, Jiřì; Alibekov, Eduard; Žegklitz, Jan; Babuska, R.; Nguyen, NT; Kowalczyk, R; Filipe, J

    2016-01-01

    This paper presents a first step of our research on designing an effective and efficient GP-based method for symbolic regression. First, we propose three extensions of the standard Single Node GP, namely (1) a selection strategy for choosing nodes to be mutated based on depth and performance of

  12. Sentinel lymph nodes in cancer of the oral cavity

    DEFF Research Database (Denmark)

    Thomsen, Jørn Bo; Christensen, Rikke Kølby; Sørensen, Jens Ahm

    2007-01-01

    when compared with (B) step-sectioning and immunostaining of the entire sentinel lymph node at 250 microM levels. METHODS: Forty patients with T1/T2 cN0 oral cancer were enrolled. Three patients were excluded. In one patient no sentinel lymph node was identified. The remaining two had unidentified...

  13. A Gene Expression Classifier of Node-Positive Colorectal Cancer

    Directory of Open Access Journals (Sweden)

    Paul F. Meeh

    2009-10-01

    Full Text Available We used digital long serial analysis of gene expression to discover gene expression differences between node-negative and node-positive colorectal tumors and developed a multigene classifier able to discriminate between these two tumor types. We prepared and sequenced long serial analysis of gene expression libraries from one node-negative and one node-positive colorectal tumor, sequenced to a depth of 26,060 unique tags, and identified 262 tags significantly differentially expressed between these two tumors (P < 2 x 10-6. We confirmed the tag-to-gene assignments and differential expression of 31 genes by quantitative real-time polymerase chain reaction, 12 of which were elevated in the node-positive tumor. We analyzed the expression levels of these 12 upregulated genes in a validation panel of 23 additional tumors and developed an optimized seven-gene logistic regression classifier. The classifier discriminated between node-negative and node-positive tumors with 86% sensitivity and 80% specificity. Receiver operating characteristic analysis of the classifier revealed an area under the curve of 0.86. Experimental manipulation of the function of one classification gene, Fibronectin, caused profound effects on invasion and migration of colorectal cancer cells in vitro. These results suggest that the development of node-positive colorectal cancer occurs in part through elevated epithelial FN1 expression and suggest novel strategies for the diagnosis and treatment of advanced disease.

  14. Critical Issues in Modelling Lymph Node Physiology

    Directory of Open Access Journals (Sweden)

    Dmitry Grebennikov

    2016-12-01

    Full Text Available In this study, we discuss critical issues in modelling the structure and function of lymph nodes (LNs, with emphasis on how LN physiology is related to its multi-scale structural organization. In addition to macroscopic domains such as B-cell follicles and the T cell zone, there are vascular networks which play a key role in the delivery of information to the inner parts of the LN, i.e., the conduit and blood microvascular networks. We propose object-oriented computational algorithms to model the 3D geometry of the fibroblastic reticular cell (FRC network and the microvasculature. Assuming that a conduit cylinder is densely packed with collagen fibers, the computational flow study predicted that the diffusion should be a dominating process in mass transport than convective flow. The geometry models are used to analyze the lymph flow properties through the conduit network in unperturbed- and damaged states of the LN. The analysis predicts that elimination of up to 60%–90% of edges is required to stop the lymph flux. This result suggests a high degree of functional robustness of the network.

  15. Temporal node centrality in complex networks

    Science.gov (United States)

    Kim, Hyoungshick; Anderson, Ross

    2012-02-01

    Many networks are dynamic in that their topology changes rapidly—on the same time scale as the communications of interest between network nodes. Examples are the human contact networks involved in the transmission of disease, ad hoc radio networks between moving vehicles, and the transactions between principals in a market. While we have good models of static networks, so far these have been lacking for the dynamic case. In this paper we present a simple but powerful model, the time-ordered graph, which reduces a dynamic network to a static network with directed flows. This enables us to extend network properties such as vertex degree, closeness, and betweenness centrality metrics in a very natural way to the dynamic case. We then demonstrate how our model applies to a number of interesting edge cases, such as where the network connectivity depends on a small number of highly mobile vertices or edges, and show that our centrality definition allows us to track the evolution of connectivity. Finally we apply our model and techniques to two real-world dynamic graphs of human contact networks and then discuss the implication of temporal centrality metrics in the real world.

  16. Breast cancer with axillary lymph node involvement

    International Nuclear Information System (INIS)

    Belaid, A.; Kanoun, S.; Kallel, A.; Ghorbel, I.; Azoury, F.; Heymann, S.; Marsiglia, H.; Bourgier, C.; Belaid, A.; Ghorbel, I.; Kanoun, S.; Kallel, A.; Pichenot, C.; Verstraet, R.; Marsiglia, H.

    2010-01-01

    Breast cancer is the most frequent cancer of women in western countries. There are one million new cases per year in the world which represents 22% of all female cancers, and more than 370.000 deaths due to breast cancer per year (14% of cancer mortality). More than half of breast cancers are associated with axillary nodal involvement. Post-operative radiation therapy (XRT) is a crucial part of locoregional treatment in axillary nodal involvement breast cancer owing to a 15-years risk reduction of locoregional recurrence of 70% and to a 5.4% risk reduction of specific mortality. In 3D-conformal irradiation in such breast cancers, target volumes are chest wall when mastectomy was performed or breast and boost of tumor bed in case of breast conservative surgery, and supra-clavicular and/or axillary and/or internal mammary node areas. The main organs at risk are ipsilateral lung, heart and brachial plexus. The aim of this article is to describe epidemiologic, radio anatomic and prognostic features of axillary nodal involvement breast cancer and to propose guidelines for 3D-conformal treatment planning in locally advanced breast cancers. This review is illustrated by a case report. (authors)

  17. Cognitive Scout Node for Communication in Disaster Scenarios

    Directory of Open Access Journals (Sweden)

    Rajesh K. Sharma

    2012-01-01

    highly desired to manage unexpected situations that may happen in a disaster scenario. The scout node proposed in this paper is an extended concept based on a powerful CR node in a heterogeneous nodes environment which takes a leading role for highly flexible, fast, and robust establishment of cooperative wireless links in a disaster situation. This node should have two components: one is a passive sensor unit that collects and stores the technical knowledge about the electromagnetic environment in a data processing unit so-called “radio environment map” in the form of a dynamically updated database, and other is an active transceiver unit which can automatically be configured either as a secondary node for opportunistic communication or as a cooperative base station or access point for primary network in emergency communications. Scout solution can be viable by taking advantage of the technologies used by existing radio surveillance systems in the context of CR.

  18. Edge- and Node-Disjoint Paths in P Systems

    Directory of Open Access Journals (Sweden)

    Michael J. Dinneen

    2010-10-01

    Full Text Available In this paper, we continue our development of algorithms used for topological network discovery. We present native P system versions of two fundamental problems in graph theory: finding the maximum number of edge- and node-disjoint paths between a source node and target node. We start from the standard depth-first-search maximum flow algorithms, but our approach is totally distributed, when initially no structural information is available and each P system cell has to even learn its immediate neighbors. For the node-disjoint version, our P system rules are designed to enforce node weight capacities (of one, in addition to edge capacities (of one, which are not readily available in the standard network flow algorithms.

  19. Uptake and retention of insufflated tantalum by lymph nodes

    International Nuclear Information System (INIS)

    Kilpper, R.W.; Bianco, A.; Gibb, F.R.; Landman, S.; Morrow, P.E.

    1976-01-01

    A nonsacrifice, radiographic technique is presented for evaluating the lymph node uptake of radiographically dense materials from the lungs of beagle dogs into which the material was insufflated. With tantalum as the contrast agent, lymph nodes sometimes become visible within 2 days after exposure when the insufflation resulted in radiographic ''alveolarization'' of some of the tantalum. Localization of the material within the nodes was observed in subsequent radiographs as well as persistent retention after as much as 1 year. Through the use of preinsufflation control films and tantalum foils of varying thickness, densitometric methods for determining the amount of tantalum within the lymph nodes are being investigated. Tantalum-182 is being used to follow the lung retention of the material as well as to verify estimates of burdens in harvested nodes. Preliminary lymphokinetic data are presented from experiments utilizing powders of 1 and 5 μm (mean) particle sizes

  20. Estimation of dose and exposure at sentinel node study

    International Nuclear Information System (INIS)

    Skopljak, A.; Kucukalic-Selimovic, E.; Beslic, N.; Begic, A.; Begovic-Hadzimuratovic, S.; Drazeta, Z.; Beganovic, A.

    2005-01-01

    The purpose of this study was to estimate the dose end exposure in staff involved in sentinel node procedure for breast cancer patients. The Institute of Nuclear Medicine in Sarajevo uses a protocol for lymphoscintigraphy of the sentinel node whereby 13 MBq of 9 9mT c nanocoll are used. In this study, we measured radiation doses and exposure of a nuclear medicine physician and a technologist, as well as a surgeon performing sentinel node lymphoscintigraphy and biopsy. Dose and exposure were calculated using the equation in which we have gamma constant for 9 9mT c. Calculations were made for different times of exposure and distance. In Table 1. we estimated the dose and exposure during sentinel node study. Radiation levels were very low and the most exposed hospital staff performing sentinel node study were nuclear medicine physicians. The doses on the hands of surgeons were negligible 8 hours after exposure.(author)

  1. Effects of transuranics on pulmonary lymph nodes of rodents

    International Nuclear Information System (INIS)

    Sanders, C.L.

    1976-01-01

    Pulmonary lymph nodes have been suggested as the ''critical'' tissue for insoluble, inhaled transuranic compounds owing to the high concentration of transuranics in these lymph nodes. About 800 rats were given from 0.2 to 3600 nCi of 238 PuO 2 or 239 PuO 2 by inhalation, intratracheal instillation, intrapleural injection, or intraperitoneal injection. From about 1 to 10 percent of deposited plutonium was translocated to pulmonary lymph nodes, the amount depending on the time after deposition and the route of administration; 238 PuO 2 was cleared from pulmonary lymph nodes faster than 239 PuO 2 owing to the greater in vivo solubility of 238 PuO 2 . No primary tumors of pulmonary lymph nodes were observed, indicating that this tissue was not the critical tissue for carcinogenic induction

  2. GFT centrality: A new node importance measure for complex networks

    Science.gov (United States)

    Singh, Rahul; Chakraborty, Abhishek; Manoj, B. S.

    2017-12-01

    Identifying central nodes is very crucial to design efficient communication networks or to recognize key individuals of a social network. In this paper, we introduce Graph Fourier Transform Centrality (GFT-C), a metric that incorporates local as well as global characteristics of a node, to quantify the importance of a node in a complex network. GFT-C of a reference node in a network is estimated from the GFT coefficients derived from the importance signal of the reference node. Our study reveals the superiority of GFT-C over traditional centralities such as degree centrality, betweenness centrality, closeness centrality, eigenvector centrality, and Google PageRank centrality, in the context of various arbitrary and real-world networks with different degree-degree correlations.

  3. Spinal Schmorl's nodes: Sagittal sectional imaging and pathological examination

    International Nuclear Information System (INIS)

    Silberstein, M.; Opeskin, K.

    1999-01-01

    The presence, location and number of Schmorl's nodes was determined in the thoracolumbar spines of 70 motor vehicle accident victims using radiographic examination of a midline sagittal section and subsequent pathological examinations, including histology. In 28% of spines, a greater number of Schmorl's nodes were identified with radiography, while in 44%, pathological examination revealed a greater number of nodes. The visibility of Schmorl's nodes was enhanced by using a sagittal radiographic approach, and, in contrast to previous work, nodes below 0.5 cm 2 were readily detected. The results of the present study offer an additional imaging technique for postmortem analysis of the spine, and support the use of sagittal MR imaging for the evaluation of this condition. Copyright (1999) Blackwell Science Pty Ltd

  4. Assessing node risk and vulnerability in epidemics on networks

    Science.gov (United States)

    Rogers, T.

    2015-01-01

    Which nodes are most vulnerable to an epidemic spreading through a network, and which carry the highest risk of causing a major outbreak if they are the source of the infection? Here we show how these questions can be answered to good approximation using the cavity method. Several curious properties of node vulnerability and risk are explored: some nodes are more vulnerable than others to weaker infections, yet less vulnerable to stronger ones; a node is always more likely to be caught in an outbreak than it is to start one, except when the disease has a deterministic lifetime; the rank order of node risk depends on the details of the distribution of infectious periods.

  5. JACEE long duration balloon flights

    International Nuclear Information System (INIS)

    Burnett, T.; Iwai, J.; Lord, J.J.; Strausz, S.; Wilkes, R.J.; Dake, S.; Oda, H.; Miyamura, O.; Fuki, M.; Jones, W.V.; Gregory, J.; Hayashi, T.; Takahashi, U.; Tominaga, Y.; Wefel, J.P.; Fountain, W.; Derrickson, J.; Parnell, T.A.; Roberts, E.; Tabuki, T.; Watts, J.W.

    1989-01-01

    JACEE balloon-borne emulsion chamber detectors are used to observe the spectra and interactions of cosmic ray protons and nuclei in the energy range 1-100A TeV. Experience with long duration mid-latitude balloon flights and characteristics of the detector system that make it ideal for planned Antarctic balloon flights are discussed. 5 refs., 2 figs

  6. Capital flight and political risk

    NARCIS (Netherlands)

    Lensink, R; Hermes, N; Murinde, [No Value

    This paper provides the first serious attempt to examine the relationship between political risk and capital flight for a large set of developing countries. The outcomes of the analysis show that in most cases political risk variables do have a statistically robust relationship to capital flight

  7. Passengers waste production during flights.

    Science.gov (United States)

    Tofalli, Niki; Loizia, Pantelitsa; Zorpas, Antonis A

    2017-12-20

    We assume that during flights the amount of waste that is produced is limited. However, daily, approximately 8000 commercial airplanes fly above Europe's airspace while at the same time, more than 17,000 commercial flights exist in the entire world. Using primary data from airlines, which use the Larnaca's International Airport (LIA) in Cyprus, we have tried to understand why wastes are produced during a typical flight such as food waste, paper, and plastics, as well as how passengers affect the production of those wastes. The compositional analysis took place on 27 flights of 4 different airlines which used LIA as final destination. The evaluation indicated that the passenger's habits and ethics, and the policy of each airline produced different kinds of waste during the flights and especially food waste (FW). Furthermore, it was observed that the only waste management strategy that exists in place in the airport is the collection and the transportation of all those wastes from aircrafts and from the airport in the central unit for further treatment. Hence, this research indicated extremely difficulties to implement any specific waste minimization, or prevention practice or other sorting methods during the flights due to the limited time of the most flights (less than 3 h), the limited available space within the aircrafts, and the strictly safety roles that exist during the flights.

  8. [Prediction of lateral lymph node metastasis by magnetic resonance imaging].

    Science.gov (United States)

    Hatano, Satoshi; Kumamoto, Kensuke; Ishibashi, Keiichiro; Ishiguro, Toru; Ohsawa, Tomonori; Okada, Norimichi; Nakata, Hiroshi; Yokoyama, Masaru; Haga, Norihiro; Ishida, Hideyuki

    2010-11-01

    Considering the advantages and disadvantages of lateral lymph node dissection in patients with advanced lower rectal cancer, it would be ideal to select candidates for lateral lymph node dissection by preoperative imaging study including magnetic resonance imaging(MRI). We have reported that the cut-off value of minimal diameter of lateral lymph node could be set at 6 mm for indication of lateral lymph node dissection. In the present study, we evaluated whether it would be appropriate to apply the cut-off value of minimal diameter of lateral lymph node in MRI. Forty-four patients with advanced lower rectal cancer underwent a curative surgery with lateral lymph node dissection or sampling from 1997 to 2009 in our institute. Among them, 25 patients received MRI preoperatively and analyzed. The images were obtained by a sagittal method that was diagonal along sacro-iliac joint with 5 mm thick sections. Lateral lymph node metastasis was detected in 5 cases, one side in 4 cases and both sides in 1 case. The sensitivity, specificity, positive predict value, and accuracy for predicting metastasis was 50%, 90%, 42.9% and 84.8% respectively, when the cut-off value of the minimal diameter was set at 6 mm in MRI. Our results indicated that a 6 mm set as the cut-off value of minimal diameter of lateral lymph node was suitable for the prediction of lateral lymph node metastasis since the accuracy was relatively high (84.8%), though it was hardly to detect metastatic lymph node less than 6 mm.

  9. Prediction of lateral lymph node metastasis by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Hatano, Satoshi; Kumamoto, Kensuke; Ishibashi, Keiichiro

    2010-01-01

    Considering the advantages and disadvantages of lateral lymph node dissection in patients with advanced lower rectal cancer, it would be ideal to select candidates for lateral lymph node dissection by preoperative imaging study including magnetic resonance imaging (MRI). We have reported that the cut-off value of minimal diameter of lateral lymph node could be set at 6 mm for indication of lateral lymph node dissection. In the present study, we evaluated whether it would be appropriate to apply the cut-off value of minimal diameter of lateral lymph node in MRI. Forty-four patients with advanced lower rectal cancer underwent a curative surgery with lateral lymph node dissection or sampling from 1997 to 2009 in our institute. Among them, 25 patients received MRI preoperatively and analyzed. The images were obtained by a sagittal method that was diagonal along sacro-iliac joint with 5 mm thick sections. Lateral lymph node metastasis was detected in 5 cases, one side in 4 cases and both sides in 1 case. The sensitivity, specificity, positive predict value, and accuracy for predicting metastasis was 50%, 90%, 42.9% and 84.8% respectively, when the cut-off value of the minimal diameter was set at 6 mm in MRI. Our results indicated that a 6 mm set as the cut-off value of minimal diameter of lateral lymph node was suitable for the prediction of lateral lymph node metastasis since the accuracy was relatively high (84.8%), though it was hardly to detect metastatic lymph node less than 6 mm. (author)

  10. Sentinel lymph node biopsy in node-negative squamous cell carcinoma of the oral cavity and oropharynx.

    LENUS (Irish Health Repository)

    Burns, P

    2012-02-01

    OBJECTIVES: Considerable controversy exists regarding the merits of elective neck dissection in patients with early stage oral cavity and oropharyngeal squamous cell carcinoma. It is highly desirable to have a method of identifying those patients who would benefit from further treatment of the neck when they are clinically node-negative. The purpose of the present study was to examine the use of sentinel lymph node biopsy in identifying occult neck disease in a cohort of patients with node-negative oral cavity and oropharyngeal squamous cell carcinoma. DESIGN: We evaluated a total of 13 patients with oral cavity and oropharyngeal cancer who were clinically and radiologically node-negative. RESULTS: A sentinel lymph node was found in all 13 patients, revealing metastatic disease in five patients, four of whom had one or more positive sentinel lymph nodes. There was one false negative result, in which the sentinel lymph node was negative for tumour whereas histological examination of the neck dissection specimen showed occult disease. CONCLUSION: In view of these findings, we would recommend the use of sentinel lymph node biopsy in cases of oral cavity and oropharyngeal squamous cell carcinoma, in order to aid the differentiation of those patients whose necks are harbouring occult disease and who require further treatment.

  11. Aggregating job exit statuses of a plurality of compute nodes executing a parallel application

    Science.gov (United States)

    Aho, Michael E.; Attinella, John E.; Gooding, Thomas M.; Mundy, Michael B.

    2015-07-21

    Aggregating job exit statuses of a plurality of compute nodes executing a parallel application, including: identifying a subset of compute nodes in the parallel computer to execute the parallel application; selecting one compute node in the subset of compute nodes in the parallel computer as a job leader compute node; initiating execution of the parallel application on the subset of compute nodes; receiving an exit status from each compute node in the subset of compute nodes, where the exit status for each compute node includes information describing execution of some portion of the parallel application by the compute node; aggregating each exit status from each compute node in the subset of compute nodes; and sending an aggregated exit status for the subset of compute nodes in the parallel computer.

  12. Prognostic relevance of lymph node ratio and total lymph node count for small bowel adenocarcinoma.

    Science.gov (United States)

    Tran, Thuy B; Qadan, Motaz; Dua, Monica M; Norton, Jeffrey A; Poultsides, George A; Visser, Brendan C

    2015-08-01

    Nodal metastasis is a known prognostic factor for small bowel adenocarcinoma. The goals of this study were to evaluate the number of lymph nodes (LNs) that should be retrieved and the impact of lymph node ratio (LNR) on survival. Surveillance, Epidemiology, and End Results was queried to identify patients with small bowel adenocarcinoma who underwent resection from 1988 to 2010. Survival was calculated with the Kaplan-Meier method. Multivariate analysis identified predictors of survival. A total of 2,772 patients underwent resection with at least one node retrieved, and this sample included equal numbers of duodenal (n = 1,387) and jejunoileal (n = 1,386) adenocarcinomas. There were 1,371 patients with no nodal metastasis (N0, 49.4%), 928 N1 (33.5%), and 474 N2 (17.1%). The median numbers of LNs examined for duodenal and jejunoileal cancers were 9 and 8, respectively. Cut-point analysis demonstrated that harvesting at least 9 for jejunoileal and 5 LN for duodenal cancers resulted in the greatest survival difference. Increasing LNR at both sites was associated with decreased overall median survival (LNR = 0, 71 months; LNR 0-0.02, 35 months; LNR 0.21-0.4, 25 months; and LNR >0.4, 16 months; P < .001). Multivariate analysis confirmed number of LNs examined, T-stage, LN positivity, and LNR were independent predictors of survival. LNR has a profound impact on survival in patients with small bowel adenocarcinoma. To achieve adequate staging, we recommend retrieving a minimum of 5 LN for duodenal and 9 LN for jejunoileal adenocarcinomas. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. IVGEN Post Flight Analysis

    Science.gov (United States)

    Mcquillen, John; Brown, Dan; Hussey, Sam; Zoldak, John

    2014-01-01

    The Intravenous Fluid Generation (IVGEN) Experiment was a technology demonstration experiment that purified ISS potable water, mixed it with salt, and transferred it through a sterilizing filter. On-orbit performance was verified as appropriate and two 1.5 l bags of normal saline solution were returned to earth for post-flight testing by a FDA certified laboratory for compliance with United States Pharmacopiea (USP) standards. Salt concentration deviated from required values and an analysis identified probable causes. Current efforts are focused on Total Organic Content (TOC) testing, and shelf life.The Intravenous Fluid Generation (IVGEN) Experiment demonstrated the purification of ISS potable water, the mixing of the purified water with sodium chloride, and sterilization of the solution via membrane filtration. On-orbit performance was monitored where feasible and two 1.5-liter bags of normal saline solution were returned to earth for post-flight testing by a FDA-registered laboratory for compliance with United States Pharmacopeia (USP)standards [1]. Current efforts have been focused on challenge testing with identified [2] impurities (total organic-carbon), and shelf life testing. The challenge testing flowed known concentrations of contaminants through the IVGEN deionizing cartridge and membrane filters to test their effectiveness. One finding was that the filters and DI-resin themselves contribute to the contaminant load during initial startup, suggesting that the first 100 ml of fluid be discarded. Shelf life testing is ongoing and involves periodic testing of stored DI cartridges and membrane filters that are capped and sealed in hermetic packages. The testing is conducted at six month intervals measuring conductivity and endotoxins in the effluent. Currently, the packaging technique has been successfully demonstrated for one year of storage testing. The USP standards specifies that the TOC be conducted at point of generation as opposed to point of

  14. Radiations and space flight

    International Nuclear Information System (INIS)

    Maalouf, M.; Vogin, G.; Foray, N.; Maalouf; Vogin, G.

    2011-01-01

    A space flight is submitted to 3 main sources of radiation: -) cosmic radiation (4 protons/cm 2 /s and 10000 times less for the heaviest particles), -) solar radiation (10 8 protons/cm 2 /s in the solar wind), -) the Van Allen belt around the earth: the magnetosphere traps particles and at an altitude of 500 km the proton flux can reach 100 protons/cm 2 /s. If we take into account all the spatial missions performed since 1960, we get an average dose of 400 μGray per day with an average dose rate of 0.28 μGray/mn. A significant risk of radiation-induced cancer is expected for missions whose duration is over 250 days.The cataract appears to be the most likely non-cancerous health hazard due to the exposition to comic radiation. Its risk appears to have been under-estimated, particularly for doses over 8 mGray. Some studies on astronauts have shown for some a very strong predisposition for radio-induced cancers: during the reparation phase of DNA breaking due to irradiation, multiple new damages are added by the cells themselves that behave abnormally. (A.C.)

  15. Final report for the mobile node authentication LDRD project.

    Energy Technology Data Exchange (ETDEWEB)

    Michalski, John T.; Lanzone, Andrew J.

    2005-09-01

    In hostile ad hoc wireless communication environments, such as battlefield networks, end-node authentication is critical. In a wired infrastructure, this authentication service is typically facilitated by a centrally-located ''authentication certificate generator'' such as a Certificate Authority (CA) server. This centralized approach is ill-suited to meet the needs of mobile ad hoc networks, such as those required by military systems, because of the unpredictable connectivity and dynamic routing. There is a need for a secure and robust approach to mobile node authentication. Current mechanisms either assign a pre-shared key (shared by all participating parties) or require that each node retain a collection of individual keys that are used to communicate with other individual nodes. Both of these approaches have scalability issues and allow a single compromised node to jeopardize the entire mobile node community. In this report, we propose replacing the centralized CA with a distributed CA whose responsibilities are shared between a set of select network nodes. To that end, we develop a protocol that relies on threshold cryptography to perform the fundamental CA duties in a distributed fashion. The protocol is meticulously defined and is implemented it in a series of detailed models. Using these models, mobile wireless scenarios were created on a communication simulator to test the protocol in an operational environment and to gather statistics on its scalability and performance.

  16. Temporal-varying failures of nodes in networks

    Science.gov (United States)

    Knight, Georgie; Cristadoro, Giampaolo; Altmann, Eduardo G.

    2015-08-01

    We consider networks in which random walkers are removed because of the failure of specific nodes. We interpret the rate of loss as a measure of the importance of nodes, a notion we denote as failure centrality. We show that the degree of the node is not sufficient to determine this measure and that, in a first approximation, the shortest loops through the node have to be taken into account. We propose approximations of the failure centrality which are valid for temporal-varying failures, and we dwell on the possibility of externally changing the relative importance of nodes in a given network by exploiting the interference between the loops of a node and the cycles of the temporal pattern of failures. In the limit of long failure cycles we show analytically that the escape in a node is larger than the one estimated from a stochastic failure with the same failure probability. We test our general formalism in two real-world networks (air-transportation and e-mail users) and show how communities lead to deviations from predictions for failures in hubs.

  17. Adaptive filtering for hidden node detection and tracking in networks.

    Science.gov (United States)

    Hamilton, Franz; Setzer, Beverly; Chavez, Sergio; Tran, Hien; Lloyd, Alun L

    2017-07-01

    The identification of network connectivity from noisy time series is of great interest in the study of network dynamics. This connectivity estimation problem becomes more complicated when we consider the possibility of hidden nodes within the network. These hidden nodes act as unknown drivers on our network and their presence can lead to the identification of false connections, resulting in incorrect network inference. Detecting the parts of the network they are acting on is thus critical. Here, we propose a novel method for hidden node detection based on an adaptive filtering framework with specific application to neuronal networks. We consider the hidden node as a problem of missing variables when model fitting and show that the estimated system noise covariance provided by the adaptive filter can be used to localize the influence of the hidden nodes and distinguish the effects of different hidden nodes. Additionally, we show that the sequential nature of our algorithm allows for tracking changes in the hidden node influence over time.

  18. Identifying key nodes in multilayer networks based on tensor decomposition.

    Science.gov (United States)

    Wang, Dingjie; Wang, Haitao; Zou, Xiufen

    2017-06-01

    The identification of essential agents in multilayer networks characterized by different types of interactions is a crucial and challenging topic, one that is essential for understanding the topological structure and dynamic processes of multilayer networks. In this paper, we use the fourth-order tensor to represent multilayer networks and propose a novel method to identify essential nodes based on CANDECOMP/PARAFAC (CP) tensor decomposition, referred to as the EDCPTD centrality. This method is based on the perspective of multilayer networked structures, which integrate the information of edges among nodes and links between different layers to quantify the importance of nodes in multilayer networks. Three real-world multilayer biological networks are used to evaluate the performance of the EDCPTD centrality. The bar chart and ROC curves of these multilayer networks indicate that the proposed approach is a good alternative index to identify real important nodes. Meanwhile, by comparing the behavior of both the proposed method and the aggregated single-layer methods, we demonstrate that neglecting the multiple relationships between nodes may lead to incorrect identification of the most versatile nodes. Furthermore, the Gene Ontology functional annotation demonstrates that the identified top nodes based on the proposed approach play a significant role in many vital biological processes. Finally, we have implemented many centrality methods of multilayer networks (including our method and the published methods) and created a visual software based on the MATLAB GUI, called ENMNFinder, which can be used by other researchers.

  19. Exploring the evolution of node neighborhoods in Dynamic Networks

    Science.gov (United States)

    Orman, Günce Keziban; Labatut, Vincent; Naskali, Ahmet Teoman

    2017-09-01

    Dynamic Networks are a popular way of modeling and studying the behavior of evolving systems. However, their analysis constitutes a relatively recent subfield of Network Science, and the number of available tools is consequently much smaller than for static networks. In this work, we propose a method specifically designed to take advantage of the longitudinal nature of dynamic networks. It characterizes each individual node by studying the evolution of its direct neighborhood, based on the assumption that the way this neighborhood changes reflects the role and position of the node in the whole network. For this purpose, we define the concept of neighborhood event, which corresponds to the various transformations such groups of nodes can undergo, and describe an algorithm for detecting such events. We demonstrate the interest of our method on three real-world networks: DBLP, LastFM and Enron. We apply frequent pattern mining to extract meaningful information from temporal sequences of neighborhood events. This results in the identification of behavioral trends emerging in the whole network, as well as the individual characterization of specific nodes. We also perform a cluster analysis, which reveals that, in all three networks, one can distinguish two types of nodes exhibiting different behaviors: a very small group of active nodes, whose neighborhood undergo diverse and frequent events, and a very large group of stable nodes.

  20. Sentinel lymph node biopsy in local recurrence of cutaneous melanoma

    International Nuclear Information System (INIS)

    Junqueira, G. Jr.; Bodanese, B.; Boff, M.F.; Espindola, M.B.; Haack, R.L.; Frigeri, C.D.L.

    2004-01-01

    Full text: Locally recurrent disease in patients with melanoma is usually defined as cutaneous or subcutaneous arising within 5 cm of the primary site after complete excision of the primary lesion. It may represent residual disease not excised with the primary tumor or the outgrowth of the satellite lesions, which are common with melanoma. Lymphatic mapping and sentinel lymph node (SLN) biopsy is highly accurate in staging nodal basins at risk of regional metastases in primary melanoma patients and identifies those who may benefit from earlier lymphadenectomy. Our purpose was to evaluate the efficacy of sentinel lymph node mapping and biopsy in local recurrence of cutaneous melanoma when the primary lesion was less than 1.0mm thick. Three patients with local recurrence of cutaneous melanoma underwent sentinel lymph node mapping and biopsy. All patients underwent preoperative lymphoscintigraphy to identify the lymphatic basin and the site of the sentinel node. All patients subsequently underwent intra-operative lymphatic mapping and selective lymph node biopsy with vital blue dye and hand-held gamma probe. Excised SLN were analysed by conventional histological staining (H and E) and immunohistochemical staining. In all patients the lymphatic mapping and sentinel lymph node biopsy was successful. The SLN biopsy was negative in two patients and positive in one who underwent therapeutic lymph node dissection. Our results indicate that the SLN mapping and biopsy is also possible in patients having local recurrence of cutaneous melanoma. Although long-term results are not available, early results are promising. (author)

  1. Feasibility of sentinel node lymphoscintigraphy in stage I testicular cancer

    Energy Technology Data Exchange (ETDEWEB)

    Tanis, Pieter J.; Nieweg, Omgo E. [Department of Surgery, Netherlands Cancer Institute, Amsterdam (Netherlands); Horenblas, Simon [Department of Urology, Netherlands Cancer Institute, Amsterdam (Netherlands); Olmos, Renato Valdes A.; Hoefnagel, Cornelis A. [Department of Nuclear Medicine, The Netherlands Cancer Institute, Amsterdam (Netherlands)

    2002-05-01

    The aim of this study was to investigate the feasibility of lymphoscintigraphy for sentinel node identification in testicular cancer. Five patients with clinical stage I testicular cancer were prospectively included. A single dose of technetium-99m nanocolloid (mean dose 99 MBq, volume 0.2 ml) was injected into the funiculus in the first patient and into the testicular parenchyma in the following four patients. Dynamic lymphoscintigraphy was performed over 10 min, followed by early and late static images after 15 min and 2 to 24 h, respectively. Lymphoscintigraphy was followed by laparoscopic sentinel node biopsy on the same day in the last two patients using patent blue dye and an endoscopic gamma probe. The funicular administration route showed five hot spots in the right inguinal region after 2 h. Intratesticular administration resulted in sentinel node visualisation in three of the four patients. Dynamic images showed afferent lymphatic vessels to one sentinel node in the left para-aortic region in two patients and two sentinel nodes in the left para-aortic region in another patient. Sentinel nodes were intraoperatively identified in one of two patients who underwent laparoscopic exploration. It is concluded that lymphoscintigraphy for sentinel node identification is feasible in stage I testicular cancer using intratesticular radiocolloid administration. (orig.)

  2. IceBridge Mission Flight Reports

    Data.gov (United States)

    National Aeronautics and Space Administration — The IceBridge Mission Flight Reports data set contains flight reports from NASA Operation IceBridge Greenland, Arctic, Antarctic, and Alaska missions. Flight reports...

  3. High risk of non-sentinel node metastases in a group of breast cancer patients with micrometastases in the sentinel node

    DEFF Research Database (Denmark)

    Tvedskov, Tove Filtenborg; Jensen, Maj-Britt; Lisse, Ida Marie

    2012-01-01

    Axillary lymph node dissection (ALND) in breast cancer patients with positive sentinel nodes is under debate. We aimed to establish two models to predict non-sentinel node (NSN) metastases in patients with micrometastases or isolated tumor cells (ITC) in sentinel nodes, to guide the decision for ...

  4. Heart rate variability and short duration spaceflight: relationship to post-flight orthostatic intolerance

    Directory of Open Access Journals (Sweden)

    Blaber Andrew P

    2004-04-01

    Full Text Available Abstract Background Upon return from space many astronauts experience symptoms of orthostatic intolerance. Research has implicated altered autonomic cardiovascular regulation due to spaceflight with further evidence to suggest that there might be pre-flight autonomic indicators of post-flight orthostatic intolerance. We used heart rate variability (HRV to determine whether autonomic regulation of the heart in astronauts who did or did not experience post-flight orthostatic intolerance was different pre-flight and/or was differentially affected by short duration (8 – 16 days spaceflight. HRV data from ten-minute stand tests collected from the 29 astronauts 10 days pre-flight, on landing day and three days post-flight were analysed using coarse graining spectral analysis. From the total power (PTOT, the harmonic component was extracted and divided into high (PHI: >0.15 Hz and low (PLO: = 0.15 Hz frequency power regions. Given the distribution of autonomic nervous system activity with frequency at the sinus node, PHI/PTOT was used as an indicator of parasympathetic activity; PLO/PTOT as an indicator of sympathetic activity; and, PLO/PHI as an estimate of sympathovagal balance. Results Twenty-one astronauts were classified as finishers, and eight as non-finishers, based on their ability to remain standing for 10 minutes on landing day. Pre-flight, non-finishers had a higher supine PHI/PTOT than finishers. Supine PHI/PTOT was the same pre-flight and on landing day in the finishers; whereas, in the non-finishers it was reduced. The ratio PLO/PHI was lower in non-finishers compared to finishers and was unaffected by spaceflight. Pre-flight, both finishers and non-finishers had similar supine values of PLO/PTOT, which increased from supine to stand. Following spaceflight, only the finishers had an increase in PLO/PTOT from supine to stand. Conclusions Both finishers and non-finishers had an increase in sympathetic activity with stand on pre-flight

  5. Node-based measures of connectivity in genetic networks.

    Science.gov (United States)

    Koen, Erin L; Bowman, Jeff; Wilson, Paul J

    2016-01-01

    At-site environmental conditions can have strong influences on genetic connectivity, and in particular on the immigration and settlement phases of dispersal. However, at-site processes are rarely explored in landscape genetic analyses. Networks can facilitate the study of at-site processes, where network nodes are used to model site-level effects. We used simulated genetic networks to compare and contrast the performance of 7 node-based (as opposed to edge-based) genetic connectivity metrics. We simulated increasing node connectivity by varying migration in two ways: we increased the number of migrants moving between a focal node and a set number of recipient nodes, and we increased the number of recipient nodes receiving a set number of migrants. We found that two metrics in particular, the average edge weight and the average inverse edge weight, varied linearly with simulated connectivity. Conversely, node degree was not a good measure of connectivity. We demonstrated the use of average inverse edge weight to describe the influence of at-site habitat characteristics on genetic connectivity of 653 American martens (Martes americana) in Ontario, Canada. We found that highly connected nodes had high habitat quality for marten (deep snow and high proportions of coniferous and mature forest) and were farther from the range edge. We recommend the use of node-based genetic connectivity metrics, in particular, average edge weight or average inverse edge weight, to model the influences of at-site habitat conditions on the immigration and settlement phases of dispersal. © 2015 John Wiley & Sons Ltd.

  6. Protograph LDPC Codes with Node Degrees at Least 3

    Science.gov (United States)

    Divsalar, Dariush; Jones, Christopher

    2006-01-01

    In this paper we present protograph codes with a small number of degree-3 nodes and one high degree node. The iterative decoding threshold for proposed rate 1/2 codes are lower, by about 0.2 dB, than the best known irregular LDPC codes with degree at least 3. The main motivation is to gain linear minimum distance to achieve low error floor. Also to construct rate-compatible protograph-based LDPC codes for fixed block length that simultaneously achieves low iterative decoding threshold and linear minimum distance. We start with a rate 1/2 protograph LDPC code with degree-3 nodes and one high degree node. Higher rate codes are obtained by connecting check nodes with degree-2 non-transmitted nodes. This is equivalent to constraint combining in the protograph. The condition where all constraints are combined corresponds to the highest rate code. This constraint must be connected to nodes of degree at least three for the graph to have linear minimum distance. Thus having node degree at least 3 for rate 1/2 guarantees linear minimum distance property to be preserved for higher rates. Through examples we show that the iterative decoding threshold as low as 0.544 dB can be achieved for small protographs with node degrees at least three. A family of low- to high-rate codes with minimum distance linearly increasing in block size and with capacity-approaching performance thresholds is presented. FPGA simulation results for a few example codes show that the proposed codes perform as predicted.

  7. Nutritional Biochemistry of Space Flight

    Science.gov (United States)

    Smith, Scott M.

    2000-01-01

    Adequate nutrition is critical for maintenance of crew health during and after extended-duration space flight. The impact of weightlessness on human physiology is profound, with effects on many systems related to nutrition, including bone, muscle, hematology, fluid and electrolyte regulation. Additionally, we have much to learn regarding the impact of weightlessness on absorption, mtabolism , and excretion of nutrients, and this will ultimately determine the nutrient requirements for extended-duration space flight. Existing nutritional requirements for extended-duration space flight have been formulated based on limited flight research, and extrapolation from ground-based research. NASA's Nutritional Biochemistry Laboratory is charged with defining the nutritional requirements for space flight. This is accomplished through both operational and research projects. A nutritional status assessment program is included operationally for all International Space Station astronauts. This medical requirement includes biochemical and dietary assessments, and is completed before, during, and after the missions. This program will provide information about crew health and nutritional status, and will also provide assessments of countermeasure efficacy. Ongoing research projects include studies of calcium and bone metabolism, and iron absorption and metabolism. The calcium studies include measurements of endocrine regulation of calcium homeostasis, biochemical marker of bone metabolism, and tracer kinetic studies of calcium movement in the body. These calcium kinetic studies allow for estimation of intestinal absorption, urinary excretion, and perhaps most importantly - deposition and resorption of calcium from bone. The Calcium Kinetics experiment is currently being prepared for flight on the Space Shuttle in 2001, and potentially for subsequent Shuttle and International Space Station missions. The iron study is intended to assess whether iron absorption is down-regulated dUl1ng

  8. Morphing Flight Control Surface for Advanced Flight Performance, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — In this SBIR project, a new Morphing Flight Control Surface (MFCS) will be developed. The distinction of the research effort is that the SenAnTech team will employ...

  9. Neuroendocrine tumor of the inguinal node: A very rare presentation

    Directory of Open Access Journals (Sweden)

    Niharika Bisht

    2017-12-01

    Full Text Available Neuroendocrine tumors are a broad family of tumors arising most commonly in the gastrointestinal tract and the bronchus pulmonary tree. The other common sounds are the parathyroid, pituitary and adrenal gland. Inguinal node as a primary presentation of a neuroendocrine tumor is an extremely rare presentation. We present the case of a 43-year-old-male who presented with the complaints of an inguinal node swelling without any other symptoms and on further evaluation was diagnosed to have a non-metastatic neuroendocrine tumor of the inguinal node. He was treated with a combination of chemotherapy and surgery and is presently awaiting completion chemotherapy.

  10. On Identifying which Intermediate Nodes Should Code in Multicast Networks

    DEFF Research Database (Denmark)

    Pinto, Tiago; Roetter, Daniel Enrique Lucani; Médard, Muriel

    2013-01-01

    the data packets. Previous work has shown that in lossless wireline networks, the performance of tree-packing mechanisms is comparable to network coding, albeit with added complexity at the time of computing the trees. This means that most nodes in the network need not code. Thus, mechanisms that identify...... intermediate nodes that do require coding is instrumental for the efficient operation of coded networks and can have a significant impact in overall energy consumption. We present a distributed, low complexity algorithm that allows every node to identify if it should code and, if so, through what output link...

  11. Sustained operation of sensor nodes with energy harvesters and supercapacitors

    Energy Technology Data Exchange (ETDEWEB)

    Renner, Bernd-Christian

    2013-06-01

    Sensor nodes powered by energy harvesters and supercapacitors open the door to unlimited and uninterrupted operation. This dissertation closes the persistent gap of system integration w.r.t. holistic online energy assessment, develops a new concept for harvest forecasting while assessing the behavior and quality of known approaches, and proposes a novel load adaptation scheme to achieve sustained and uniform sensor node operation with low complexity and computational overhead. For this purpose, a prototype of an energy harvester with a supercapacitor for off-the-shelf sensor nodes is developed and used for practical evaluation.

  12. Glial membranes at the node of Ranvier prevent neurite outgrowth

    DEFF Research Database (Denmark)

    Huang, Jeffrey K; Phillips, Greg R; Roth, Alejandro D

    2005-01-01

    of neurite outgrowth, including the oligodendrocyte myelin glycoprotein (OMgp). In rat spinal cord, OMgp was not localized to compact myelin, as previously thought, but to oligodendroglia-like cells, whose processes converge to form a ring that completely encircles the nodes. In OMgp-null mice, CNS nodes......Nodes of Ranvier are regularly placed, nonmyelinated axon segments along myelinated nerves. Here we show that nodal membranes isolated from the central nervous system (CNS) of mammals restricted neurite outgrowth of cultured neurons. Proteomic analysis of these membranes revealed several inhibitors...

  13. Design of node record for fast active reflector

    International Nuclear Information System (INIS)

    Wu Wenqing; Luo Mingcheng; Tang Pengyi; Liu Jiajing; Wang Jian

    2014-01-01

    Active Reflector is the one of the innovations of Five hundred meter Aperture Spherical Telescope (FAST) whose performance touches on that of the overall telescope. Therefore a real time control system is needed by the Active Reflector System. In this paper, a new record type-node record is designed for EPICS-based active reflector control system of FAST, according to more than 2000 controlled node, which will be convenient for node management of IOC and prove the reusage of IOC codes. The record type is used in design of active reflector control system of FAST Miyun model. (authors)

  14. Irradiating the groin nodes without breaking a leg: A comparison of techniques for groin node irradiation

    International Nuclear Information System (INIS)

    Gilroy, Jeffrey S.; Amdur, Robert J.; Louis, Debbie A.; Li, Jonathan G.; Mendenhall, William M.

    2004-01-01

    The purpose of this study was to determine the optimal technique for delivering postoperative radiotherapy for vulvar cancer and other tumors requiring treatment of the inguinal nodes. This project compared tumor coverage and normal tissue sparing for the 5 main radiotherapy techniques that are used to treat vulvar cancer. The intensity-modulated radiation therapy (IMRT) plan was undesirable because it resulted in an excessive dose to portions of the central pelvic structures. The photon thunderbird with skin match was unacceptable because it underdosed a portion of the groin region. The electron thunderbird was ideal for thin patients but was not applicable for most patients because of excessive dose to the skin and subcutaneous tissues. The photon through-and-through and the photon thunderbird with deep match were acceptable in most situations. In thin patients, where the depth of the inguinal vessels is less than 3 cm, the electron thunderbird is the technique of choice. In the average-sized patient, both the photon through-and-through and the photon thunderbird with deep match are reasonable options. The available literature suggests that the risk of femoral neck fracture or necrosis of the femoral head is approximately 11% at 5 years using the photon through-and-through technique. In our opinion, this is an acceptable price to pay for reliable node coverage, setup simplicity, and zero risk of overdose at field junctions

  15. DETECTION OF OCCULT LYMPH NODE TUMOR CELLS IN NODE-NEGATIVE GASTRIC CANCER PATIENTS.

    Science.gov (United States)

    Pereira, Marina Alessandra; Ramos, Marcus Fernando Kodama Pertille; Dias, Andre Roncon; Yagi, Osmar Kenji; Faraj, Sheila Friedrich; Zilberstein, Bruno; Cecconello, Ivan; Mello, Evandro Sobroza de; Ribeiro, Ulysses

    2017-01-01

    The presence of lymph nodes metastasis is one of the most important prognostic indicators in gastric cancer. The micrometastases have been studied as prognostic factor in gastric cancer, which are related to decrease overall survival and increased risk of recurrence. However, their identification is limited by conventional methodology, since they can be overlooked after routine staining. To investigate the presence of occult tumor cells using cytokeratin (CK) AE1/AE3 immunostaining in gastric cancer patients histologically lymph node negative (pN0) by H&E. Forty patients (T1-T4N0) submitted to a potentially curative gastrectomy with D2 lymphadenectomy were evaluated. The results for metastases, micrometastases and isolated tumor cells were also associated to clinicopathological characteristics and their impact on stage grouping. Tumor deposits within lymph nodes were defined according to the tumor-node-metastases guidelines (7th TNM). A total of 1439 lymph nodes were obtained (~36 per patient). Tumor cells were detected by immunohistochemistry in 24 lymph nodes from 12 patients (30%). Neoplasic cells were detected as a single or cluster tumor cells. Tumor (p=0.002), venous (p=0.016), lymphatic (p=0.006) and perineural invasions (p=0.04), as well as peritumoral lymphocytic response (p=0.012) were correlated to CK-positive immunostaining tumor cells in originally negative lymph nodes by H&E. The histologic stage of two patients was upstaged from stage IB to stage IIA. Four of the 28 CK-negative patients (14.3%) and three among 12 CK-positive patients (25%) had disease recurrence (p=0.65). The CK-immunostaining is an effective method for detecting occult tumor cells in lymph nodes and may be recommended to precisely determine tumor stage. It may be useful as supplement to H&E routine to provide better pathological staging. A presença de metástase em linfonodos é um dos indicadores prognósticos mais importantes no câncer gástrico. As micrometástases têm sido

  16. Enclosure enhancement of flight performance

    KAUST Repository

    Ghommem, Mehdi; Garcia, Daniel; Calo, Victor M.

    2014-01-01

    We use a potential flow solver to investigate the aerodynamic aspects of flapping flights in enclosed spaces. The enclosure effects are simulated by the method of images. Our study complements previous aerodynamic analyses which considered only the near-ground flight. The present results show that flying in the proximity of an enclosure affects the aerodynamic performance of flapping wings in terms of lift and thrust generation and power consumption. It leads to higher flight efficiency and more than 5% increase of the generation of lift and thrust.

  17. Enclosure enhancement of flight performance

    Directory of Open Access Journals (Sweden)

    Mehdi Ghommem

    2014-01-01

    Full Text Available We use a potential flow solver to investigate the aerodynamic aspects of flapping flights in enclosed spaces. The enclosure effects are simulated by the method of images. Our study complements previous aerodynamic analyses which considered only the near-ground flight. The present results show that flying in the proximity of an enclosure affects the aerodynamic performance of flapping wings in terms of lift and thrust generation and power consumption. It leads to higher flight efficiency and more than 5% increase of the generation of lift and thrust.

  18. Enclosure enhancement of flight performance

    KAUST Repository

    Ghommem, Mehdi

    2014-08-19

    We use a potential flow solver to investigate the aerodynamic aspects of flapping flights in enclosed spaces. The enclosure effects are simulated by the method of images. Our study complements previous aerodynamic analyses which considered only the near-ground flight. The present results show that flying in the proximity of an enclosure affects the aerodynamic performance of flapping wings in terms of lift and thrust generation and power consumption. It leads to higher flight efficiency and more than 5% increase of the generation of lift and thrust.

  19. Theseus Landing Following Maiden Flight

    Science.gov (United States)

    1996-01-01

    The Theseus prototype research aircraft shows off its high aspect-ratio wing as it comes in for a landing on Rogers Dry Lake after its first test flight from NASA's Dryden Flight Research Center, Edwards, California, on May 24, 1996. The Theseus aircraft, built and operated by Aurora Flight Sciences Corporation, Manassas, Virginia, was a unique aircraft flown at NASA's Dryden Flight Research Center, Edwards, California, under a cooperative agreement between NASA and Aurora. Dryden hosted the Theseus program, providing hangar space and range safety for flight testing. Aurora Flight Sciences was responsible for the actual flight testing, vehicle flight safety, and operation of the aircraft. The Theseus remotely piloted aircraft flew its maiden flight on May 24, 1996, at Dryden. During its sixth flight on November 12, 1996, Theseus experienced an in-flight structural failure that resulted in the loss of the aircraft. As of the beginning of the year 2000, Aurora had not rebuilt the aircraft. Theseus was built for NASA under an innovative, $4.9 million fixed-price contract by Aurora Flight Sciences Corporation and its partners, West Virginia University, Morgantown, West Virginia, and Fairmont State College, Fairmont, West Virginia. The twin-engine, unpiloted vehicle had a 140-foot wingspan, and was constructed largely of composite materials. Powered by two 80-horsepower, turbocharged piston engines that drove twin 9-foot-diameter propellers, Theseus was designed to fly autonomously at high altitudes, with takeoff and landing under the active control of a ground-based pilot in a ground control station 'cockpit.' With the potential ability to carry 700 pounds of science instruments to altitudes above 60,000 feet for durations of greater than 24 hours, Theseus was intended to support research in areas such as stratospheric ozone depletion and the atmospheric effects of future high-speed civil transport aircraft engines. Instruments carried aboard Theseus also would be able

  20. Lymph node metastasis of carcinomas of transverse colon including flexures. Consideration of the extramesocolic lymph node stations.

    Science.gov (United States)

    Perrakis, Aristotelis; Weber, Klaus; Merkel, Susanne; Matzel, Klaus; Agaimy, Abbas; Gebbert, Carol; Hohenberger, Werner

    2014-10-01

    Complete mesocolic excision (CME) is nowadays state of the art in the treatment of colon cancer. In cases of carcinoma of transverse colon and of both flexures an extramesocolic lymph node metastasis can be found in the infrapancreatic lymph node region (ILR) and across the gastroepiploic arcade (GLR). These direct metastatic routes were not previously systematically considered. In order to validate our hypothesis of these direct metastatic pathways and to obtain evidence of our approach of including dissection of these areas as part of CME, we initiated a prospective study evaluating these lymph node regions during surgery. Forty-five consecutive patients with primary tumour manifestation in transverse colon and both flexures between May 2010 and January 2013 were prospectively analyzed. Patients were followed up for at least 6 months. Mode of surgery, histopathology, morbidity and mortality were evaluated. Twenty-six patients had a carcinoma of transverse colon, 16 patients one of hepatic flexure and four patients one of splenic flexure. The median lymph node yield was 40. Occurrence of lymph node metastasis in ILR was registered in five patients and in GLR in four patients. The mean lymph node ratio was 0.085. Postoperative complications occurred in nine patients, and postoperative mortality was 2 %. We were able to demonstrate this novel metastatic route of carcinomas of the transverse colon and of both flexures in ILR and GLR. These could be considered as regional lymph node regions and have to be included into surgery for cancer of the transverse colon including both flexures.

  1. Factors associated with involvement of four or more axillary nodes for sentinel lymph node-positive patients

    International Nuclear Information System (INIS)

    Katz, Angela; Niemierko, Andrzej; Gage, Irene; Evans, Sheila; Shaffer, Margaret; Smith, Frederick P.; Taghian, Alphonse; Magnant, Colette

    2006-01-01

    Purpose: Sentinel lymph node-positive (SLN+) patients who are unlikely to have 4 or more involved axillary nodes might be treated with less extensive regional nodal radiation. The purpose of this study was to define possible predictors of having 4 or more involved axillary nodes. Methods and Materials: The records of 224 patients with breast cancer and 1 to 3 involved SLNs, who underwent completion axillary dissection without neoadjuvant chemotherapy or hormonal therapy were reviewed. Factors associated with the presence of 4 or more involved axillary nodes (SLNs plus non-SLNs) were evaluated by Pearson chi-square test of association and by simple and multiple logistic-regression analysis. Results: Of 224 patients, 42 had involvement of 4 or more axillary nodes. On univariate analysis, the presence of 4 or more involved axillary nodes was positively associated with increased tumor size, lobular histology, lymphovascular space invasion (LVSI), increased number of involved SLNs, decreased number of uninvolved SLNs, and increased size of SLN metastasis. On multivariate analysis, the presence of 4 or more involved axillary nodes was associated with LVSI, increased number of involved SLNs, increased size of SLN metastasis, and lobular histology. Conclusions: Patients with 1 or more involved SLN, LVSI, or SLN macrometastasis should be treated to the supraclavicular fossa/axillary apex if they do not undergo completion axillary dissection. Other SLN+ patients might be adequately treated with less extensive radiation fields

  2. Sick sinus syndrome in HCN1-deficient mice.

    Science.gov (United States)

    Fenske, Stefanie; Krause, Stefanie C; Hassan, Sami I H; Becirovic, Elvir; Auer, Franziska; Bernard, Rebekka; Kupatt, Christian; Lange, Philipp; Ziegler, Tilman; Wotjak, Carsten T; Zhang, Henggui; Hammelmann, Verena; Paparizos, Christos; Biel, Martin; Wahl-Schott, Christian A

    2013-12-17

    Sinus node dysfunction (SND) is a major clinically relevant disease that is associated with sudden cardiac death and requires surgical implantation of electric pacemaker devices. Frequently, SND occurs in heart failure and hypertension, conditions that lead to electric instability of the heart. Although the pathologies of acquired SND have been studied extensively, little is known about the molecular and cellular mechanisms that cause congenital SND. Here, we show that the HCN1 protein is highly expressed in the sinoatrial node and is colocalized with HCN4, the main sinoatrial pacemaker channel isoform. To characterize the cardiac phenotype of HCN1-deficient mice, a detailed functional characterization of pacemaker mechanisms in single isolated sinoatrial node cells, explanted beating sinoatrial node preparation, telemetric in vivo electrocardiography, echocardiography, and in vivo electrophysiology was performed. On the basis of these experiments we demonstrate that mice lacking the pacemaker channel HCN1 display congenital SND characterized by bradycardia, sinus dysrhythmia, prolonged sinoatrial node recovery time, increased sinoatrial conduction time, and recurrent sinus pauses. As a consequence of SND, HCN1-deficient mice display a severely reduced cardiac output. We propose that HCN1 stabilizes the leading pacemaker region within the sinoatrial node and hence is crucial for stable heart rate and regular beat-to-beat variation. Furthermore, we suggest that HCN1-deficient mice may be a valuable genetic disease model for human SND.

  3. Detection of Genetic Alterations in Breast Sentinel Lymph Node by Array-CGH

    National Research Council Canada - National Science Library

    Cavalli, Luciane R

    2005-01-01

    The sentinel lymph node (SLN) is the first node in the mammary gland to harbor malignant cells in breast tumors with metastasis, and SLN positivity is an indication for axillary lymph node dissection...

  4. Detection of Genetic Alterations in Breast Sentinel Lymph Node by Array-CGH

    National Research Council Canada - National Science Library

    Cavalli, Luciane R

    2006-01-01

    The sentinel lymph node (SLN) is the first node in the mammary gland to harbor malignant cells in breast tumors with metastasis, and SLN positivity is an indication for axillary lymph node dissection...

  5. "Space flight is utter bilge"

    Science.gov (United States)

    Yeomans, Donald

    2004-01-01

    Despite skepticism and ridicule from scientists and the public alike, a small handful of dreamers kept faith in their vision of space flight and planned for the day when humanity would break loose from Earth.

  6. Robust Decentralized Formation Flight Control

    Directory of Open Access Journals (Sweden)

    Zhao Weihua

    2011-01-01

    Full Text Available Motivated by the idea of multiplexed model predictive control (MMPC, this paper introduces a new framework for unmanned aerial vehicles (UAVs formation flight and coordination. Formulated using MMPC approach, the whole centralized formation flight system is considered as a linear periodic system with control inputs of each UAV subsystem as its periodic inputs. Divided into decentralized subsystems, the whole formation flight system is guaranteed stable if proper terminal cost and terminal constraints are added to each decentralized MPC formulation of the UAV subsystem. The decentralized robust MPC formulation for each UAV subsystem with bounded input disturbances and model uncertainties is also presented. Furthermore, an obstacle avoidance control scheme for any shape and size of obstacles, including the nonapriorily known ones, is integrated under the unified MPC framework. The results from simulations demonstrate that the proposed framework can successfully achieve robust collision-free formation flights.

  7. A Radiation Hardened Housekeeping Slave Node (RH-HKSN) ASIC

    Data.gov (United States)

    National Aeronautics and Space Administration — This projects seeks to continue the development of the Radiation Hardened Housekeeping Slave Node (RH-HKSN) ASIC. The effort has taken parallel paths by implementing...

  8. A local-world node deleting evolving network model

    International Nuclear Information System (INIS)

    Gu Yuying; Sun Jitao

    2008-01-01

    A new type network growth rule which comprises node addition with the concept of local-world connectivity and node deleting is studied. A series of theoretical analysis and numerical simulation to the LWD network are conducted in this Letter. Firstly, the degree distribution p(k) of this network changes no longer pure scale free but truncates by an exponential tail and the truncation in p(k) increases as p a decreases. Secondly, the connectivity is tighter, as the local-world size M increases. Thirdly, the average path length L increases and the clustering coefficient decreases as generally node deleting increases. Finally, trends up when the local-world size M increases, so as to k max . Hence, the expanding local-world can compensate the infection of the node deleting

  9. A local-world node deleting evolving network model

    Energy Technology Data Exchange (ETDEWEB)

    Gu Yuying [Department of Mathematics, Tongji University, Shanghai 200092 (China); Sun Jitao [Department of Mathematics, Tongji University, Shanghai 200092 (China)], E-mail: sunjt@sh163.net

    2008-06-16

    A new type network growth rule which comprises node addition with the concept of local-world connectivity and node deleting is studied. A series of theoretical analysis and numerical simulation to the LWD network are conducted in this Letter. Firstly, the degree distribution p(k) of this network changes no longer pure scale free but truncates by an exponential tail and the truncation in p(k) increases as p{sub a} decreases. Secondly, the connectivity is tighter, as the local-world size M increases. Thirdly, the average path length L increases and the clustering coefficient decreases as generally node deleting increases. Finally, trends up when the local-world size M increases, so as to k{sub max}. Hence, the expanding local-world can compensate the infection of the node deleting.

  10. [Intraoperative detection of the sentinel lymph nodes in lung cancer].

    Science.gov (United States)

    Akopov, A L; Papayan, G V; Chistyakov, I V

    2015-01-01

    An analysis of the scientific data was made. It was used the literature devoted to the intraoperative visualization of the sentinel lymph nodes in patients with lung cancer. Correct detection of such lymph nodes with following pathologic investigation allowed limiting the volume of lympho-dissection in a number of patients. There is the possibility of maximal in-depth study of the sentinel lymph nodes by purposeful application of most sensible pathologic and molecular methods for detection their micrometastatic lesions. At the same time the treatment strategy and prognosis could be determined. The authors present the results of an application of dye techniques, radioactive preparation and fluorescence imaging for sentinel lymph node detection. Advantages and disadvantages of the methods are shown in the article. There are validated the prospects of technical development, study of information value of new applications and the most perspective method of fluorescence indocyanine green visualization by lymph outflow.

  11. WHOI MVCO 12m Node ADCP SOS, 2008-present

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Wave observations from the 12m node ADCP in the Martha's Vineyard Coastal Observatory (MVCO) in the northwest Atlantic in coastal waters of North America. Extensive,...

  12. Utilisation of Decision Tables for Proposal of Transfer Node Conception

    Directory of Open Access Journals (Sweden)

    Martin Jacura

    2012-09-01

    Full Text Available The key issue in improving the appeal of public mass transport is the optimal arrangement of transfer nodes. The objective is to propose a comfortable, simple and safe environment for both passengers and operators, and a solution which is economical to construct and operate. Although each transfer node is unique and specific, it is beneficial to have a general idea on the layout of a project to construct or reconstruct such a transfer node. This project should, in particular, stem from the traffic intensity of single transport modes, the volume of single transfer links, and the nature and significance of traffic routes. This article presents the methodology for determining the appropriate disposition of mass public transport nodes using modified decision tables (one of the tools of systems analysis with specific data particularly applicable in the Czech Republic.

  13. 3D inkjet printed disposable environmental monitoring wireless sensor node

    KAUST Repository

    Farooqui, Muhammad Fahad; Shamim, Atif

    2017-01-01

    We propose a disposable, miniaturized, moveable, fully integrated 3D inkjet-printed wireless sensor node for large area environmental monitoring applications. As a proof of concept, we show the wireless sensing of temperature, humidity and H2S

  14. Flexible wearable sensor nodes with solar energy harvesting.

    Science.gov (United States)

    Taiyang Wu; Arefin, Md Shamsul; Redoute, Jean-Michel; Yuce, Mehmet Rasit

    2017-07-01

    Wearable sensor nodes have gained a lot of attention during the past few years as they can monitor and record people's physical parameters in real time. Wearable sensor nodes can promote healthy lifestyles and prevent the occurrence of potential illness or injuries. This paper presents a flexible wearable sensor system powered by an efficient solar energy harvesting technique. It can measure the subject's heartbeats using a photoplethysmography (PPG) sensor and perform activity monitoring using an accelerometer. The solar energy harvester adopts an output current based maximum power point tracking (MPPT) algorithm, which controls the solar panel to operate within its high output power range. The power consumption of the flexible sensor nodes has been investigated under different operation conditions. Experimental results demonstrate that wearable sensor nodes can work for more than 12 hours when they are powered by the solar energy harvester for 3 hours in the bright sunlight.

  15. Two Phases Authentication Level (TPAL) protocol for nodes ...

    African Journals Online (AJOL)

    ... node may contain sensitive informations such as military data and monitoring data. ... LLN is a kind of Internet of Things (IoT) network with limited power source ... Current authentication Internet protocols cannot be adopted directly into LLN ...

  16. ASH : Tackling node mobility in large-scale networks

    NARCIS (Netherlands)

    Pruteanu, A.; Dulman, S.

    2012-01-01

    With the increased adoption of technologies likewireless sensor networks by real-world applications, dynamic network topologies are becoming the rule rather than the exception. Node mobility, however, introduces a range of problems (communication interference, path uncertainty, low quality of

  17. Information loss method to measure node similarity in networks

    Science.gov (United States)

    Li, Yongli; Luo, Peng; Wu, Chong

    2014-09-01

    Similarity measurement for the network node has been paid increasing attention in the field of statistical physics. In this paper, we propose an entropy-based information loss method to measure the node similarity. The whole model is established based on this idea that less information loss is caused by seeing two more similar nodes as the same. The proposed new method has relatively low algorithm complexity, making it less time-consuming and more efficient to deal with the large scale real-world network. In order to clarify its availability and accuracy, this new approach was compared with some other selected approaches on two artificial examples and synthetic networks. Furthermore, the proposed method is also successfully applied to predict the network evolution and predict the unknown nodes' attributions in the two application examples.

  18. Mirror node correlations tuning synchronization in multiplex networks

    Science.gov (United States)

    Kumar, Anil; Baptista, Murilo S.; Zaikin, Alexey; Jalan, Sarika

    2017-12-01

    We show that the degree-degree correlations have a major impact on global synchronizability (GS) of multiplex networks, enabling the specification of synchronizability by only changing the degree-degree correlations of the mirror nodes while maintaining the connection architecture of the individual layer unaltered. If individual layers have nodes that are mildly correlated, the multiplex network is best synchronizable when the mirror degrees are strongly negatively correlated. If individual layers have nodes with strong degree-degree correlations, mild correlations among the degrees of mirror nodes are the best strategy for the optimization of GS. Global synchronization also depend on the density of connections, a phenomenon not observed in a single layer network. The results are crucial to understand, predict, and specify behavior of systems having multiple types of connections among the interacting units.

  19. Ultrasound elastography for evaluation of cervical lymph nodes

    Directory of Open Access Journals (Sweden)

    Young Jun Choi

    2015-07-01

    Full Text Available Ultrasound (US elastography has been introduced as a noninvasive imaging technique for evaluating cervical lymph nodes. US elastography techniques include strain elastography and shear wave-based elastography. The application of this technique is based on the fact that stiff tissues tend to deform less and show less strain than compliant tissues when the same force is applied. In general, metastatic lymph nodes demonstrate higher stiffness than benign lymph nodes. Overall, preliminary studies suggest that US elastography may be useful in differentiating benign and malignant cervical lymph nodes, thereby informing decisions to perform a biopsy and facilitating follow-up. For US elastography to be accepted into clinical practice, however, its techniques, associated diagnostic criteria, and reliability need to be further refined.

  20. Sensors for Detection of Misbehaving Nodes in MANETs

    OpenAIRE

    Klenk, Andreas; Kragl, Frank; Schlott, Stefan; Weber, Michael

    2004-01-01

    The fact that security is a critical problem when implementing mobile ad hoc networks (MANETs) is widely acknowledged. One of the different kinds of misbehavior a node may exhibit is selfishness. A selfish node wants to preserve its resources while using the services of others and consuming their resources. One way of preventing selfishness in a MANET is a detection and exclusion mechanism. In this paper, we focus on the detection and present different kinds of sensors that wil...

  1. Eviction of Misbehaving and Faulty Nodes in Vehicular Networks

    OpenAIRE

    Raya, Maxim; Papadimitratos, Panagiotis; Aad, Imad; Jungels, Daniel; Hubaux, Jean-Pierre

    2007-01-01

    Vehicular Networks (VNs) are emerging, among civilian applications, as a convincing instantiation of the mobile networking technology. However, security is a critical factor and a significant challenge to be met. Misbehaving or faulty network nodes have to be detected and prevented from disrupting network operation, a problem particularly hard to address in the life-critical VN environment. Existing networks rely mainly on node certificate revocation for attacker eviction, but the lack of an ...

  2. Sentinel lymph nodes in cancer of the oral cavity

    DEFF Research Database (Denmark)

    Thomsen, Jørn Bo; Sørensen, Jens Ahm; Krogdahl, Annelise

    2005-01-01

    BACKGROUND: Sentinel lymph node biopsy, step sectioning and immunohistochemistry have changed detection of tumour deposits. Isolated tumour cells (ITC) are detected more frequently than earlier because of a changed level of detection. METHODS: A total of 108 sentinel lymph nodes from 30 patients ...... with macrometastasis, five with micrometastasis and two with ITC. CONCLUSION: The ITC are probably precursors of micrometastasis waiting to grow and should be treated as such. Benign inclusions and dendritic cells did not cause problems, but can mimic ITC....

  3. Multi-Source Energy Harvesting for Wireless Sensor Nodes.

    OpenAIRE

    Kang, Kai

    2012-01-01

    The past few years have seen an increasing interest in the development of wireless sensor networks. But the unsatisfactory or limited available energy source is one of the major bottlenecks which are limiting the wireless sensor technology from mass deployment. Ambient energy harvesting is the most promising solution towards autonomous sensor nodes by providing low cost, permanent, and maintenance-free energy source to wireless sensor nodes. In this paper, we first invested available energy s...

  4. Immunolymphoscintigraphy for metastatic sentinel nodes: test of a model

    DEFF Research Database (Denmark)

    Chakera, A H; Nielsen, B S; Madsen, J

    2011-01-01

    Aim. To develop a method and obtain proof-of-principle for immunolymphoscintigraphy for identification of metastatic sentinel nodes. Methods. We selected one of four tumour-specific antibodies against human breast cancer and investigated (1), in immune-deficient (nude) mice with xenograft human b...... in healthy rabbits. Results and Conclusion. Our paper suggests the theoretical possibility of a model of dual isotope immuno-lymphoscintigraphy for noninvasive, preoperative, malignant sentinel node imaging....

  5. Lymph Node Metastases Optical Molecular Diagnostic and Radiation Therapy

    Science.gov (United States)

    2017-03-01

    Pogue CONTRACTING ORGANIZATION: Trustees of Dartmouth College Hanover, NH 03755 REPORT DATE: March 2017 TYPE OF REPORT: Annual PREPARED FOR: U.S...FORM TO THE ABOVE ADDRESS. 1. REPORT DATE March 2017 2. REPORT TYPE Annual 3. DATES COVERED 1 Mar 2016 - 28 Feb 2017 4. TITLE AND SUBTITLE Lymph...Gamma imaging of sentinel nodes is not a disease diagnostic, but rather just used to find the node and remove it for pathological inspection. As a result

  6. Solar array flight dynamic experiment

    Science.gov (United States)

    Schock, Richard W.

    1987-01-01

    The purpose of the Solar Array Flight Dynamic Experiment (SAFDE) is to demonstrate the feasibility of on-orbit measurement and ground processing of large space structures' dynamic characteristics. Test definition or verification provides the dynamic characteristic accuracy required for control systems use. An illumination/measurement system was developed to fly on space shuttle flight STS-41D. The system was designed to dynamically evaluate a large solar array called the Solar Array Flight Experiment (SAFE) that had been scheduled for this flight. The SAFDE system consisted of a set of laser diode illuminators, retroreflective targets, an intelligent star tracker receiver and the associated equipment to power, condition, and record the results. In six tests on STS-41D, data was successfully acquired from 18 retroreflector targets and ground processed, post flight, to define the solar array's dynamic characteristic. The flight experiment proved the viability of on-orbit test definition of large space structures dynamic characteristics. Future large space structures controllability should be greatly enhanced by this capability.

  7. Monitoring Traffic Information with a Developed Acceleration Sensing Node

    Directory of Open Access Journals (Sweden)

    Zhoujing Ye

    2017-12-01

    Full Text Available In this paper, an acceleration sensing node for pavement vibration was developed to monitor traffic information, including vehicle speed, vehicle types, and traffic flow, where a hardware design with low energy consumption and node encapsulation could be accomplished. The service performance of the sensing node was evaluated, by methods including waterproof test, compression test, sensing performance analysis, and comparison test. The results demonstrate that the sensing node is low in energy consumption, high in strength, IPX8 waterproof, and high in sensitivity and resolution. These characteristics can be applied to practical road environments. Two sensing nodes were spaced apart in the direction of travelling. In the experiment, three types of vehicles passed by the monitoring points at several different speeds and values of d (the distance between the sensor and the nearest tire center line. Based on cross-correlation with kernel pre-smoothing, a calculation method was applied to process the raw data. New algorithms for traffic flow, speed, and axle length were proposed. Finally, the effects of vehicle speed, vehicle weight, and d value on acceleration amplitude were statistically evaluated. It was found that the acceleration sensing node can be used for traffic flow, vehicle speed, and other types of monitoring.

  8. Monitoring Traffic Information with a Developed Acceleration Sensing Node.

    Science.gov (United States)

    Ye, Zhoujing; Wang, Linbing; Xu, Wen; Gao, Zhifei; Yan, Guannan

    2017-12-05

    In this paper, an acceleration sensing node for pavement vibration was developed to monitor traffic information, including vehicle speed, vehicle types, and traffic flow, where a hardware design with low energy consumption and node encapsulation could be accomplished. The service performance of the sensing node was evaluated, by methods including waterproof test, compression test, sensing performance analysis, and comparison test. The results demonstrate that the sensing node is low in energy consumption, high in strength, IPX8 waterproof, and high in sensitivity and resolution. These characteristics can be applied to practical road environments. Two sensing nodes were spaced apart in the direction of travelling. In the experiment, three types of vehicles passed by the monitoring points at several different speeds and values of d (the distance between the sensor and the nearest tire center line). Based on cross-correlation with kernel pre-smoothing, a calculation method was applied to process the raw data. New algorithms for traffic flow, speed, and axle length were proposed. Finally, the effects of vehicle speed, vehicle weight, and d value on acceleration amplitude were statistically evaluated. It was found that the acceleration sensing node can be used for traffic flow, vehicle speed, and other types of monitoring.

  9. Neural node network and model, and method of teaching same

    Science.gov (United States)

    Parlos, Alexander G. (Inventor); Atiya, Amir F. (Inventor); Fernandez, Benito (Inventor); Tsai, Wei K. (Inventor); Chong, Kil T. (Inventor)

    1995-01-01

    The present invention is a fully connected feed forward network that includes at least one hidden layer 16. The hidden layer 16 includes nodes 20 in which the output of the node is fed back to that node as an input with a unit delay produced by a delay device 24 occurring in the feedback path 22 (local feedback). Each node within each layer also receives a delayed output (crosstalk) produced by a delay unit 36 from all the other nodes within the same layer 16. The node performs a transfer function operation based on the inputs from the previous layer and the delayed outputs. The network can be implemented as analog or digital or within a general purpose processor. Two teaching methods can be used: (1) back propagation of weight calculation that includes the local feedback and the crosstalk or (2) more preferably a feed forward gradient decent which immediately follows the output computations and which also includes the local feedback and the crosstalk. Subsequent to the gradient propagation, the weights can be normalized, thereby preventing convergence to a local optimum. Education of the network can be incremental both on and off-line. An educated network is suitable for modeling and controlling dynamic nonlinear systems and time series systems and predicting the outputs as well as hidden states and parameters. The educated network can also be further educated during on-line processing.

  10. Mobility and Cooperation to Thwart Node Capture Attacks in MANETs

    Directory of Open Access Journals (Sweden)

    Mauro Conti

    2009-01-01

    Full Text Available The nature of mobile ad hoc networks (MANETs, often unattended, makes this type of networks subject to some unique security issues. In particular, one of the most vexing problem for MANETs security is the node capture attack: an adversary can capture a node from the network eventually acquiring all the cryptographic material stored in it. Further, the captured node can be reprogrammed by the adversary and redeployed in the network in order to perform malicious activities. In this paper, we address the node capture attack in MANETs. We start from the intuition that mobility, in conjunction with a reduced amount of local cooperation, helps computing effectively and with a limited resource usage network global security properties. Then, we develop this intuition and use it to design a mechanism to detect the node capture attack. We support our proposal with a wide set of experiments showing that mobile networks can leverage mobility to compute global security properties, like node capture detection, with a small overhead.

  11. Lagrangian generic second order traffic flow models for node

    Directory of Open Access Journals (Sweden)

    Asma Khelifi

    2018-02-01

    Full Text Available This study sheds light on higher order macroscopic traffic flow modeling on road networks, thanks to the generic second order models (GSOM family which embeds a myriad of traffic models. It has been demonstrated that such higher order models are easily solved in Lagrangian coordinates which are compatible with both microscopic and macroscopic descriptions. The generalized GSOM model is reformulated in the Lagrangian coordinate system to develop a more efficient numerical method. The difficulty in applying this approach on networks basically resides in dealing with node dynamics. Traffic flow characteristics at node are different from that on homogeneous links. Different geometry features can lead to different critical research issues. For instance, discontinuity in traffic stream can be an important issue for traffic signal operations, while capacity drop may be crucial for lane-merges. The current paper aims to establish and analyze a new adapted node model for macroscopic traffic flow models by applying upstream and downstream boundary conditions on the Lagrangian coordinates in order to perform simulations on networks of roads, and accompanying numerical method. The internal node dynamics between upstream and downstream links are taken into account of the node model. Therefore, a numerical example is provided to underscore the efficiency of this approach. Simulations show that the discretized node model yields accurate results. Additional kinematic waves and contact discontinuities are induced by the variation of the driver attribute.

  12. Lymph node segmentation by dynamic programming and active contours.

    Science.gov (United States)

    Tan, Yongqiang; Lu, Lin; Bonde, Apurva; Wang, Deling; Qi, Jing; Schwartz, Lawrence H; Zhao, Binsheng

    2018-03-03

    Enlarged lymph nodes are indicators of cancer staging, and the change in their size is a reflection of treatment response. Automatic lymph node segmentation is challenging, as the boundary can be unclear and the surrounding structures complex. This work communicates a new three-dimensional algorithm for the segmentation of enlarged lymph nodes. The algorithm requires a user to draw a region of interest (ROI) enclosing the lymph node. Rays are cast from the center of the ROI, and the intersections of the rays and the boundary of the lymph node form a triangle mesh. The intersection points are determined by dynamic programming. The triangle mesh initializes an active contour which evolves to low-energy boundary. Three radiologists independently delineated the contours of 54 lesions from 48 patients. Dice coefficient was used to evaluate the algorithm's performance. The mean Dice coefficient between computer and the majority vote results was 83.2%. The mean Dice coefficients between the three radiologists' manual segmentations were 84.6%, 86.2%, and 88.3%. The performance of this segmentation algorithm suggests its potential clinical value for quantifying enlarged lymph nodes. © 2018 American Association of Physicists in Medicine.

  13. Compressive sensing of high betweenness centrality nodes in networks

    Science.gov (United States)

    Mahyar, Hamidreza; Hasheminezhad, Rouzbeh; Ghalebi K., Elahe; Nazemian, Ali; Grosu, Radu; Movaghar, Ali; Rabiee, Hamid R.

    2018-05-01

    Betweenness centrality is a prominent centrality measure expressing importance of a node within a network, in terms of the fraction of shortest paths passing through that node. Nodes with high betweenness centrality have significant impacts on the spread of influence and idea in social networks, the user activity in mobile phone networks, the contagion process in biological networks, and the bottlenecks in communication networks. Thus, identifying k-highest betweenness centrality nodes in networks will be of great interest in many applications. In this paper, we introduce CS-HiBet, a new method to efficiently detect top- k betweenness centrality nodes in networks, using compressive sensing. CS-HiBet can perform as a distributed algorithm by using only the local information at each node. Hence, it is applicable to large real-world and unknown networks in which the global approaches are usually unrealizable. The performance of the proposed method is evaluated by extensive simulations on several synthetic and real-world networks. The experimental results demonstrate that CS-HiBet outperforms the best existing methods with notable improvements.

  14. A Balancing Algorithm in Wireless Sensor Network Based on the Assistance of Approaching Nodes

    Directory of Open Access Journals (Sweden)

    Chengpei Tang

    2013-03-01

    Full Text Available Sensor node in wireless sensor network is a micro-embedded system with limited memory, energy and communication capabilities. Some nodes will run out of energy and exit the network earlier than other nodes because of the uneven energy consumption. This will lead to partial or complete paralysis of the whole wireless sensor network. A balancing algorithm based on the assistance of approaching nodes is proposed. Via the set theory, notes are divided into neighbor nodes set and approaching nodes set. Approaching nodes will help weaker nodes forward part of massages to balance energy consumption. Simulation result has verified the rationality and feasibility of the balancing algorithm.

  15. Information-based self-organization of sensor nodes of a sensor network

    Science.gov (United States)

    Ko, Teresa H [Castro Valley, CA; Berry, Nina M [Tracy, CA

    2011-09-20

    A sensor node detects a plurality of information-based events. The sensor node determines whether at least one other sensor node is an information neighbor of the sensor node based on at least a portion of the plurality of information-based events. The information neighbor has an overlapping field of view with the sensor node. The sensor node sends at least one communication to the at least one other sensor node that is an information neighbor of the sensor node in response to at least one information-based event of the plurality of information-based events.

  16. Medical image archive node simulation and architecture

    Science.gov (United States)

    Chiang, Ted T.; Tang, Yau-Kuo

    1996-05-01

    access time, number of drives, number of exams per patient, number of Central Processing Units, patient grouping, and priority impacts. The MIADS, which could be a key component of a broader data repository system, will be able to communicate with and obtain data from existing hospital information systems. We will discuss the external interfaces enabling MIADS to communicate with and obtain data from existing Radiology Information Systems such as the Picture Archiving and Communication System (PACS). Our system design encompasses the broader aspects of the archive node, which could include multimedia data such as image, audio, video, and free text data. This system is designed to be integrated with current hospital PACS through a Digital Imaging and Communications in Medicine interface. However, the system can also be accessed through the Internet using Hypertext Transport Protocol or Simple File Transport Protocol. Our design and simulation work will be key to implementing a successful, scalable medical image archive and distribution system.

  17. A simplified CT-based definition of the lymph node levels in the node negative neck

    International Nuclear Information System (INIS)

    Wijers, O.B.; Levendag, P.C.; Tan, T.; Dieren, E.B. van; Sornsen de Koste, J. van; Est, H. van der; Senan, S.; Nowak, P.J.C.M.

    1999-01-01

    Using three dimensional (3D) conformal radiotherapy (CRT) techniques for elective neck irradiation (ENI) may allow for local disease control to be maintained while diminishing xerostomia by eliminating major salivary glands (or parts thereof) from the treatment portals. The standardization of CT based target volumes for the clinically negative (elective) neck is a prerequisite for 3DCRT. The aim of the present study was to substantially modify an existing ('original') CT-based protocol for the delineation of the neck tar-et volume, into a more practical ('simplified') protocol. This will allow for rapid contouring and the implementation of conformal ENI in routine clinical procedures. An earlier ('original') version of the CT-based definition for elective neck node re-ions 2-5 was re-evaluated, using 15 planning CT scans of previously treated patients. The contouring guidelines were simplified by (1) using a smaller number of easily identifiable soft tissue- and bony anatomical landmarks, which in turn had to be identified in only a limited number of CT slices, and (2) by subsequently interpolating the contoured lymph node regions. The adequacy of target coverage and the sparing using both 'original' and 'simplified' delineation protocols was evaluated by DVH analysis after contouring the primary tumor, the neck and the major salivary glands in a patient with supraglottic laryngeal (SGL) carcinoma who was treated using a 3DCRT technique. The BEV projections of the 'original' and the 'simplified' versions of the 3D elective neck target showed good agreement and were found to be reproducible. The DVH's of the target and parotid glands were not significantly different using both contouring protocols. The 'simplified' protocol for the delineation of the 3D elective neck target produced both comparable target coverage and sparing of the major salivary glands. When used together with an interpolation program, this 'simplified' protocol substantial reduced the contouring

  18. Automated ISS Flight Utilities

    Science.gov (United States)

    Offermann, Jan Tuzlic

    2016-01-01

    EVADES output. As mentioned above, GEnEVADOSE makes extensive use of ROOT version 6, the data analysis framework developed at the European Organization for Nuclear Research (CERN), and the code is written to the C++11 standard (as are the other projects). My second project is the Automated Mission Reference Exposure Utility (AMREU).Unlike GEnEVADOSE, AMREU is a combination of three frameworks written in both Python and C++, also making use of ROOT (and PyROOT). Run as a combination of daily and weekly cron jobs, these macros query the SRAG database system to determine the active ISS missions, and query minute-by-minute radiation dose information from ISS-TEPC (Tissue Equivalent Proportional Counter), one of the radiation detectors onboard the ISS. Using this information, AMREU creates a corrected data set of daily radiation doses, addressing situations where TEPC may be offline or locked up by correcting doses for days with less than 95% live time (the total amount time the instrument acquires data) by averaging the past 7 days. As not all errors may be automatically detectable, AMREU also allows for manual corrections, checking an updated plaintext file each time it runs. With the corrected data, AMREU generates cumulative dose plots for each mission, and uses a Python script to generate a flight note file (.docx format) containing these plots, as well as information sections to be filled in and modified by the space weather environment officers with information specific to the week. AMREU is set up to run without requiring any user input, and it automatically archives old flight notes and information files for missions that are no longer active. My other projects involve cleaning up a large data set from the Charged Particle Directional Spectrometer (CPDS), joining together many different data sets in order to clean up information in SRAG SQL databases, and developing other automated utilities for displaying information on active solar regions, that may be used by the

  19. 14 CFR 27.151 - Flight controls.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Flight controls. 27.151 Section 27.151... STANDARDS: NORMAL CATEGORY ROTORCRAFT Flight Flight Characteristics § 27.151 Flight controls. (a) Longitudinal, lateral, directional, and collective controls may not exhibit excessive breakout force, friction...

  20. 14 CFR 29.151 - Flight controls.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Flight controls. 29.151 Section 29.151... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Flight Flight Characteristics § 29.151 Flight controls. (a) Longitudinal, lateral, directional, and collective controls may not exhibit excessive breakout force, friction...

  1. F-14 in banked flight

    Science.gov (United States)

    1979-01-01

    NASA 991, an F-14 Navy Tomcat designated the F-14 (1X), is seen here in banked flight over the desert on a research flight at NASA's Dryden Flight Research Center, Edwards, California. The F-14 was used at Dryden between 1979 and 1985 in extensive high-angle-of-attack and spin-control-and-recovery tests. The NASA/Navy program, which included 212 total flights, acheived considerable improvement in the F-14 high-angle-of-attack flying qualities, improved departure and spin resistance, and contributed to substantial improvements in reducing 'wing rock,' (i.e., tilting from one side to another), at high angles of attack. The Navy had been experiencing inadvertant spin entries caused by the F-14's aileron rudder interconnect. The NASA/Navy/Grumman team developed and tested 4 different configurations of the aileron rudder interconnect to address the spin problem. These problems prompted the Navy to ask the manufacturer, Grumman, and NASA to investigate the issue. NASA 991 had numerous special additions for high-angle-of-attack and spin-recovery research. These included a battery-powered auxiliary power unit, a flight test nose boom, and a special spin recovery system, consisting of forward mounted, hydraulically actuated canards and an emergency spin chute. NASA's F-14 was first flown by NASA research pilots, but was later flown by Grumman, and by Navy test pilots from Patuxent River Naval Air Station (NAS). The Navy test flights with the spin research vehicle constituted the first program that incorporated air combat maneuvering in its test flights at Dryden. The Navy brought F-14s from Point Mugu and Miramar NAS in San Diego to test the new spin control laws in combat situations. Although the new control laws proved valuable, the Navy did not incorporate them into production F-14s until the F-14D, nearly 15 years later.

  2. Wireless motion sensor network for monitoring motion in a process, wireless sensor node, reasoning node, and feedback and/or actuation node for such wireless motion sensor network

    NARCIS (Netherlands)

    Havinga, Paul J.M.; Marin Perianu, Raluca; Marin Perianu, Mihai

    2010-01-01

    Wireless motion sensor network for monitoring motion in a process comprising at least one wireless sensor node for measuring at least one physical quantity related to motion or orientation, feature extraction means for deriving a feature for the measured quantities, a wireless transmitter connected

  3. Predictive Factors for Nonsentinel Lymph Node Metastasis in Patients With Positive Sentinel Lymph Nodes After Neoadjuvant Chemotherapy: Nomogram for Predicting Nonsentinel Lymph Node Metastasis.

    Science.gov (United States)

    Ryu, Jai Min; Lee, Se Kyung; Kim, Ji Young; Yu, Jonghan; Kim, Seok Won; Lee, Jeong Eon; Han, Se Hwan; Jung, Yong Sik; Nam, Seok Jin

    2017-11-01

    Axillary lymph node (ALN) status is an important prognostic factor for breast cancer patients. With increasing numbers of patients undergoing neoadjuvant chemotherapy (NAC), issues concerning sentinel lymph node biopsy (SLNB) after NAC have emerged. We analyzed the clinicopathologic features and developed a nomogram to predict the possibility of nonsentinel lymph node (NSLN) metastases in patients with positive SLNs after NAC. A retrospective medical record review was performed of 140 patients who had had clinically positive ALNs at presentation, had a positive SLN after NAC on subsequent SLNB, and undergone axillary lymph node dissection (ALND) from 2008 to 2014. On multivariate stepwise logistic regression analysis, pathologic T stage, lymphovascular invasion, SLN metastasis size, and number of positive SLN metastases were independent predictors for NSLN metastases (P Samsung Medical Center NAC nomogram was developed to predict the likelihood of additional positive NSLNs. The Samsung Medical Center NAC nomogram could provide information to surgeons regarding whether to perform additional ALND when the permanent biopsy revealed positive findings, although the intraoperative SLNB findings were negative. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Aurora Flight Sciences' Perseus B Remotely Piloted Aircraft in Flight

    Science.gov (United States)

    1998-01-01

    A long, slender wing and a pusher propeller at the rear characterize the Perseus B remotely piloted research aircraft, seen here during a test flight in June 1998. Perseus B is a remotely piloted aircraft developed as a design-performance testbed under NASA's Environmental Research Aircraft and Sensor Technology (ERAST) project. Perseus is one of several flight vehicles involved in the ERAST project. A piston engine, propeller-powered aircraft, Perseus was designed and built by Aurora Flight Sciences Corporation, Manassas, Virginia. The objectives of Perseus B's ERAST flight tests have been to reach and maintain horizontal flight above altitudes of 60,000 feet and demonstrate the capability to fly missions lasting from 8 to 24 hours, depending on payload and altitude requirements. The Perseus B aircraft established an unofficial altitude record for a single-engine, propeller-driven, remotely piloted aircraft on June 27, 1998. It reached an altitude of 60,280 feet. In 1999, several modifications were made to the Perseus aircraft including engine, avionics, and flight-control-system improvements. These improvements were evaluated in a series of operational readiness and test missions at the Dryden Flight Research Center, Edwards, California. Perseus is a high-wing monoplane with a conventional tail design. Its narrow, straight, high-aspect-ratio wing is mounted atop the fuselage. The aircraft is pusher-designed with the propeller mounted in the rear. This design allows for interchangeable scientific-instrument payloads to be placed in the forward fuselage. The design also allows for unobstructed airflow to the sensors and other devices mounted in the payload compartment. The Perseus B that underwent test and development in 1999 was the third generation of the Perseus design, which began with the Perseus Proof-Of-Concept aircraft. Perseus was initially developed as part of NASA's Small High-Altitude Science Aircraft (SHASA) program, which later evolved into the ERAST

  5. Extended Lymphadenectomy to the Lower Paraortic Nodes During Radical Cystectomy

    International Nuclear Information System (INIS)

    El-Shazli, S.; Anwar, H.; Ramzy, S.; Al-Didi, M.

    2004-01-01

    Evaluation of the diagnostic, prognostic and possible therapeutic role of extended lymphadenectomy to lower para-aortic area in operable bladder cancer patients. Patients and Methods: One hundred and nine patients were subjected to the procedure in the National Cancer Institute, Cairo University, and in Minea Oncology Center, Ministry of Health by the same group of surgeons, during the period from September 2000 to March 2003. The lymph nodes dissected were labeled to the following groups: perivesical, lymph node of Cloquet, external iliac, internal iliac and obturator, common iliac and paraortic groups both right and left. These nodes were subjected with the primary tumor to serial sectioning for histopathologic examination. Preoperatively, all patients were subjected to routine laboratory investigations. [n addition to cystoscopy, biopsy and histopathologic examination, bone scan, chest X-Ray and computerized tomography with l. V. contrast examination for the abdomen and pelvis were done for clinical staging of the disease. 34.4% of the node positive patients have been found to harbor the disease in the para-aortic lymph nodes above the common iliac bifurcation. Obturator, external iliac, internal iliac, para-aortic, common iliac, perivesical and lymph node of Cloquet are the higher incidence groups of positive lymph nodes sequentially. The clinical and c.T. staging are inaccurate methods of diagnosis due to high overall error in up to 70.6% of patients. There is no higher incidence of morbidity, mortality, operative time or intraoperative blood loss related to the addition of lower para-aortic dissection to the routine radical cystectomy. Extension of lymphadenectomy to include the lower para-aortic area in addition to the standard pelvic lymphadenectomy during radical cystectomy for bladder cancer is a more accurate technique for diagnosis and staging of bladder cancer patients and it may help in determining the benefit of adjuvant chemotherapy ± radiotherapy

  6. Role of sentinel lymph node biopsy in oral cancer.

    Science.gov (United States)

    Calabrese, L; Bruschini, R; Ansarin, M; Giugliano, G; De Cicco, C; Ionna, F; Paganelli, G; Maffini, F; Werner, J A; Soutar, D

    2006-12-01

    Squamous cell carcinoma of the oral cavity represents about 2% of all malignant neoplasms and 47% of those developing in the head and neck area. The tongue is the most common site involved, and this incidence is increasing mainly in young people, possibly related to human papilloma virus infections. Prognosis depends on the stage: the 5-year survival rate of tongue squamous cell carcinoma, whatever the T stage, is 73% in pN0 cases, 40% in patients with positive nodes without extracapsular spread (pNl ECS-), and 29% when nodes are metastatic with extracapsular spread (pNl ECS+: p > or = 0.0001). Nodal micrometastases (cN0 pN1) are found in up to 50% of cN0 tongue squamous cell carcinoma patients operated on the neck. At present, no clinical, imaging staging modalities or biological markers are available to diagnose nodal micrometastases. The sentinel node biopsy has been tested since 1996 in order to find a solution to this problem. The sentinel node is the first node reached by the lymphatic stream, assuming an orderly and sequential drainage from the tumour site, and should be predictive of the nodal stage. According to the literature, sentinel node biopsy is a reliable technique in selected cN0 cases, but the procedure is still experimental and should not be performed outside validation trials. Successful application of sentinel node biopsy in the head and neck region requires surgical experience and specific technical devices, including pre-operative lymphoscintigraphy and intra-operative gamma-probe. Moreover, dynamic lymphoscintigraphy seems to be able to show the lymphatic stream from the primary tumour and could allow a selective neck dissection to be tailored thus reducing the related morbidity.

  7. In-flight sleep of flight crew during a 7-hour rest break: implications for research and flight safety.

    Science.gov (United States)

    Signal, T Leigh; Gander, Philippa H; van den Berg, Margo J; Graeber, R Curtis

    2013-01-01

    To assess the amount and quality of sleep that flight crew are able to obtain during flight, and identify factors that influence the sleep obtained. Flight crew operating flights between Everett, WA, USA and Asia had their sleep recorded polysomnographically for 1 night in a layover hotel and during a 7-h in-flight rest opportunity on flights averaging 15.7 h. Layover hotel and in-flight crew rest facilities onboard the Boeing 777-200ER aircraft. Twenty-one male flight crew (11 Captains, mean age 48 yr and 10 First Officers, mean age 35 yr). N/A. Sleep was recorded using actigraphy during the entire tour of duty, and polysomnographically in a layover hotel and during the flight. Mixed model analysis of covariance was used to determine the factors affecting in-flight sleep. In-flight sleep was less efficient (70% vs. 88%), with more nonrapid eye movement Stage 1/Stage 2 and more frequent awakenings per h (7.7/h vs. 4.6/h) than sleep in the layover hotel. In-flight sleep included very little slow wave sleep (median 0.5%). Less time was spent trying to sleep and less sleep was obtained when sleep opportunities occurred during the first half of the flight. Multivariate analyses suggest age is the most consistent factor affecting in-flight sleep duration and quality. This study confirms that even during long sleep opportunities, in-flight sleep is of poorer quality than sleep on the ground. With longer flight times, the quality and recuperative value of in-flight sleep is increasingly important for flight safety. Because the age limit for flight crew is being challenged, the consequences of age adversely affecting sleep quantity and quality need to be evaluated.

  8. System Identification of Flight Mechanical Characteristics

    OpenAIRE

    Larsson, Roger

    2013-01-01

    With the demand for more advanced fighter aircraft, relying on relaxed stability or even unstable flight mechanical characteristics to gain flight performance, more focus has been put on model-based system engineering to help with the design work. The flight control system design is one important part that relies on this modeling. Therefore it has become more important to develop flight mechanical models that are highly accurate in the whole flight envelop. For today’s newly developed fighter...

  9. Flight Demonstration of X-33 Vehicle Health Management System Components on the F/A-18 Systems Research Aircraft

    Science.gov (United States)

    Schweikhard, Keith A.; Richards, W. Lance; Theisen, John; Mouyos, William; Garbos, Raymond

    2001-01-01

    The X-33 reusable launch vehicle demonstrator has identified the need to implement a vehicle health monitoring system that can acquire data that monitors system health and performance. Sanders, a Lockheed Martin Company, has designed and developed a COTS-based open architecture system that implements a number of technologies that have not been previously used in a flight environment. NASA Dryden Flight Research Center and Sanders teamed to demonstrate that the distributed remote health nodes, fiber optic distributed strain sensor, and fiber distributed data interface communications components of the X-33 vehicle health management (VHM) system could be successfully integrated and flown on a NASA F-18 aircraft. This paper briefly describes components of X-33 VHM architecture flown at Dryden and summarizes the integration and flight demonstration of these X-33 VHM components. Finally, it presents early results from the integration and flight efforts.

  10. Supersonic Retropropulsion Flight Test Concepts

    Science.gov (United States)

    Post, Ethan A.; Dupzyk, Ian C.; Korzun, Ashley M.; Dyakonov, Artem A.; Tanimoto, Rebekah L.; Edquist, Karl T.

    2011-01-01

    NASA's Exploration Technology Development and Demonstration Program has proposed plans for a series of three sub-scale flight tests at Earth for supersonic retropropulsion, a candidate decelerator technology for future, high-mass Mars missions. The first flight test in this series is intended to be a proof-of-concept test, demonstrating successful initiation and operation of supersonic retropropulsion at conditions that replicate the relevant physics of the aerodynamic-propulsive interactions expected in flight. Five sub-scale flight test article concepts, each designed for launch on sounding rockets, have been developed in consideration of this proof-of-concept flight test. Commercial, off-the-shelf components are utilized as much as possible in each concept. The design merits of the concepts are compared along with their predicted performance for a baseline trajectory. The results of a packaging study and performance-based trade studies indicate that a sounding rocket is a viable launch platform for this proof-of-concept test of supersonic retropropulsion.

  11. 14 CFR 25.865 - Fire protection of flight controls, engine mounts, and other flight structure.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire protection of flight controls, engine... Design and Construction Fire Protection § 25.865 Fire protection of flight controls, engine mounts, and other flight structure. Essential flight controls, engine mounts, and other flight structures located in...

  12. Impact of clinical pharmacy interventions on medication error nodes.

    Science.gov (United States)

    Chamoun, Nibal R; Zeenny, Rony; Mansour, Hanine

    2016-12-01

    Background Pharmacists' involvement in patient care has improved the quality of care and reduced medication errors. However, this has required a lot of work that could not have been accomplished without documentation of interventions. Several means of documenting errors have been proposed in the literature but without a consistent comprehensive process. Recently, the American College of Clinical Pharmacy (ACCP) recognized that pharmacy practice lacks a consistent process for direct patient care and discussed several options for a pharmaceutical care plan, essentially encompassing medication therapy assessment, development and implementation of a pharmaceutical care plan and finally evaluation of the outcome. Therefore, as per the recommendations of ACCP, we sought to retrospectively analyze interventions by grouping them according to medication related problems (MRP) and their nodes such as prescribing; administering; monitoring; documenting and dispensing. Objective The aim of this study is to report interventions according to medication error (ME) nodes and show the impact of pharmacy interventions in reducing MRPs. Setting The study was conducted at the cardiology and infectious diseases services at a teaching hospital located in Beirut, Lebanon. Methods Intervention documentation was completed by pharmacy students on infectious diseases and cardiology rotations then reviewed by clinical pharmacists with respective specialties. Before data analysis, a new pharmacy reporting sheet was developed in order to link interventions according to MRP. Then, MRPs were grouped in the five ME nodes. During the documentation process, whether MRP had reached the patient or not may have not been reported which prevented the classification to the corresponding medication error nodes as ME. Main outcome Reduction in medication related problems across all ME nodes. Results A total of n = 1174 interventions were documented. N = 1091 interventions were classified as MRPs

  13. Computed tomography (CT) of cervical lymph nodes in patients with oral cancer. Comparison of low-attenuation areas in lymph nodes on CT images with pathological findings

    International Nuclear Information System (INIS)

    Fukunari, Fumiko; Okamura, Kazuhiko; Yuasa, Kenji; Kagawa, Toyohiro; Zeze, Ryousuke

    2008-01-01

    The objective of this study was to clarify the histopathological features of low-attenuation areas in computed tomography (CT) images of cervical metastatic and benign lymph nodes in patients with oral squamous cell carcinoma (SCC). CT images of 230 lymph nodes from 37 patients with oral SCC were classified into four categories and compared with histopathological findings. Metastatic lymph nodes were evaluated in terms of focal necrosis, keratinization, fibrous tissue, and the proportion of the lymph node showing focal necrosis. Benign lymph nodes were evaluated in terms of adipose tissue, follicular hyperplasia, sinus histiocytosis, hyperemia, focal hemorrhaging, and the amount of adipose tissue. Histopathologically, all 13 metastatic lymph nodes with rim enhancement on CT images included focal necrosis. However, most of the lymph nodes showed no focal necrosis. In addition, tumor cells, keratinization, and fibrous tissue were observed in the lymph nodes. Of the 26 metastatic lymph nodes with a heterogeneous appearance on CT images, four did not show focal necrosis. These lymph nodes showed keratinization or accumulation of lymph fluid. Histopathologically, 20 of 24 benign lymph nodes with a heterogeneous appearance on CT images (83.3%) had accompanying adipose tissue. Focal necrosis was the most important factor contributing to low attenuation in metastatic lymph nodes. However, other factors, such as tumor cells, keratinization, fibrous tissue, and accumulation of lymph fluid, also contributed. In benign lymph nodes, the presence of adipose tissue was a contributing factor in low-attenuation areas, as was focal hemorrhaging. (author)

  14. Human tolerance to space flight

    Science.gov (United States)

    Huntoon, C. L.

    1989-01-01

    Medical studies of astronauts and cosmonauts before, during, and after space missions have identified several effects of weightlessness and other factors that influence the ability of humans to tolerate space flight. Weightlessness effects include space motion sickness, cardiovascular abnormalities, reduction in immune system function, loss of red blood cells, loss of bone mass, and muscle atrophy. Extravehicular activity (EVA) increases the likelihood that decompression sickness may occur. Radiation also gives reason for concern about health of crewmembers, and psychological factors are important on long-term flights. Countermeasures that have been used include sensory preadaptation, prebreathing and use of various air mixtures for EVA, loading with water and electrolytes, exercise, use of pharmacological agents and special diets, and psychological support. It appears that humans can tolerate and recover satisfactorily from at least one year of space flight, but a number of conditions must be further ameliorated before long-duration missions can be considered routine.

  15. X-36 during First Flight

    Science.gov (United States)

    1997-01-01

    The remotely-piloted X-36 Tailless Fighter Agility Research Aircraft climbs out from Rogers Dry Lake at the Dryden Flight Research Center on its first flight in May 1997. The aircraft flew for five minutes and reached an altitude of approximately 4,900 feet. The NASA/Boeing X-36 Tailless Fighter Agility Research Aircraft program successfully demonstrated the tailless fighter design using advanced technologies to improve the maneuverability and survivability of possible future fighter aircraft. The program met or exceeded all project goals. For 31 flights during 1997 at the Dryden Flight Research Center, Edwards, California, the project team examined the aircraft's agility at low speed / high angles of attack and at high speed / low angles of attack. The aircraft's speed envelope reached up to 206 knots (234 mph). This aircraft was very stable and maneuverable. It handled very well. The X-36 vehicle was designed to fly without the traditional tail surfaces common on most aircraft. Instead, a canard forward of the wing was used as well as split ailerons and an advanced thrust-vectoring nozzle for directional control. The X-36 was unstable in both pitch and yaw axes, so an advanced, single-channel digital fly-by-wire control system (developed with some commercially available components) was put in place to stabilize the aircraft. Using a video camera mounted in the nose of the aircraft and an onboard microphone, the X-36 was remotely controlled by a pilot in a ground station virtual cockpit. A standard fighter-type head-up display (HUD) and a moving-map representation of the vehicle's position within the range in which it flew provided excellent situational awareness for the pilot. This pilot-in-the-loop approach eliminated the need for expensive and complex autonomous flight control systems and the risks associated with their inability to deal with unknown or unforeseen phenomena in flight. Fully fueled the X-36 prototype weighed approximately 1,250 pounds. It was 19

  16. Data acquisition remote node powered over the communications optical fiber

    International Nuclear Information System (INIS)

    Batista, Antonio J.N.; Sousa, Jorge; Gonçalves, Bruno

    2015-01-01

    Large nuclear fusion reactors, like ITER, will have harsh electromagnetic environments nearby the machine. Foreseeing the necessity for special data acquisition remote nodes, on difficult access locations and as close as possible to the experimental devices, motivated the system design. The architecture is based on the power-over-fiber technology recent advancements and respective implementation aim is to attain a proof of concept for the fusion technology field and others, e.g., high energy physics, industry, etc. The design intends the replacement of traditional copper cables and power supplies, vulnerable to electromagnetic interference, by the communications optical fiber of the data acquisition remote node. Optical fibers provide galvanic isolation, immunity to noisy electromagnetic environments and simultaneously can supply power to the remote node electronics. System architecture uses a laser power converter (array of photovoltaic cells) to convert the laser light, from the optical fiber, into electricity. The generated electrical power is enough for powering the remote node electronics and optoelectronics, such as an ADC, a low power FPGA and an optical transmitter. The laser power converter is also used as the communications receiver and from which the acquisition clock is recovered, providing synchronism between remote data acquisition nodes. Descriptions of the system architecture, tested implementations and future improvements are presented.

  17. blastjs: a BLAST+ wrapper for Node.js.

    Science.gov (United States)

    Page, Martin; MacLean, Dan; Schudoma, Christian

    2016-02-27

    To cope with the ever-increasing amount of sequence data generated in the field of genomics, the demand for efficient and fast database searches that drive functional and structural annotation in both large- and small-scale genome projects is on the rise. The tools of the BLAST+ suite are the most widely employed bioinformatic method for these database searches. Recent trends in bioinformatics application development show an increasing number of JavaScript apps that are based on modern frameworks such as Node.js. Until now, there is no way of using database searches with the BLAST+ suite from a Node.js codebase. We developed blastjs, a Node.js library that wraps the search tools of the BLAST+ suite and thus allows to easily add significant functionality to any Node.js-based application. blastjs is a library that allows the incorporation of BLAST+ functionality into bioinformatics applications based on JavaScript and Node.js. The library was designed to be as user-friendly as possible and therefore requires only a minimal amount of code in the client application. The library is freely available under the MIT license at https://github.com/teammaclean/blastjs.

  18. RootJS: Node.js Bindings for ROOT 6

    Science.gov (United States)

    Beffart, Theo; Früh, Maximilian; Haas, Christoph; Rajgopal, Sachin; Schwabe, Jonas; Wolff, Christoph; Szuba, Marek

    2017-10-01

    We present rootJS, an interface making it possible to seamlessly integrate ROOT 6 into applications written for Node.js, the JavaScript runtime platform increasingly commonly used to create high-performance Web applications. ROOT features can be called both directly from Node.js code and by JIT-compiling C++ macros. All rootJS methods are invoked asynchronously and support callback functions, allowing non-blocking operation of Node.js applications using them. Last but not least, our bindings have been designed to platform-independent and should therefore work on all systems supporting both ROOT 6 and Node.js. Thanks to rootJS it is now possible to create ROOT-aware Web applications taking full advantage of the high performance and extensive capabilities of Node.js. Examples include platforms for the quality assurance of acquired, reconstructed or simulated data, book-keeping and e-log systems, and even Web browser-based data visualisation and analysis.

  19. [The lymph nodes imprint for the diagnosis of lymphoid neoplasms].

    Science.gov (United States)

    Peniche-Alvarado, Carolina; Ramos-Peñafiel, Christian Omar; Martínez-Murillo, Carlos; Romero-Guadarrama, Mónica; Olarte-Carrillo, Irma; Rozen-Fuller, Etta; Martínez-Tovar, Adolfo; Collazo-Jaloma, Juan; Mendoza-García, Carlos Alberto

    2013-01-01

    lymphoma is the most frequent lymphoid neoplasm in our country. Its diagnosis is based on histopathological findings. The lymph node imprint has been used for more than 40 years. The aim was to establish the sensitivity, specificity, positive predictive value and negative predictive value of lymph node imprint and estimate the inter-observer rate. we did an observational, retrospective, prolective study, based on the lymph node imprint obtained by excisional biopsies over a period of 6 years. the inclusion criteria was met on 199 samples, 27.1 % were considered as reactive (n = 54), 16.1 % Hodgkin lymphoma (n = 32), 40.2 % (n = 80) non-Hodgkin lymphoma and 16.6 % (n = 33) as metastatic carcinoma. Comparing with the final histopathology report, the sensitivity and specificity of lymph node imprint were 88 % (0.81-0.95) and 64 % (0.55-0.73) respectively, the positive predictive value was 67 % (0.59-0.76) and the negative predictive value was 86 % (0.79-0.94). The interobserver kappa index was 0.467. the lymph node imprint remains as a useful tool for the diagnosis of lymphoid neoplasm. The agreement between observers was acceptable.

  20. Optimal Node Placement in Underwater Acoustic Sensor Network

    KAUST Repository

    Felemban, Muhamad

    2011-10-01

    Almost 70% of planet Earth is covered by water. A large percentage of underwater environment is unexplored. In the past two decades, there has been an increase in the interest of exploring and monitoring underwater life among scientists and in industry. Underwater operations are extremely difficult due to the lack of cheap and efficient means. Recently, Wireless Sensor Networks have been introduced in underwater environment applications. However, underwater communication via acoustic waves is subject to several performance limitations, which makes the relevant research issues very different from those on land. In this thesis, we investigate node placement for building an initial Underwater Wireless Sensor Network infrastructure. Firstly, we formulated the problem into a nonlinear mathematic program with objectives of minimizing the total transmission loss under a given number of sensor nodes and targeted volume. We conducted experiments to verify the proposed formulation, which is solved using Matlab optimization tool. We represented each node with a truncated octahedron to fill out the 3D space. The truncated octahedrons are tiled in the 3D space with each node in the center where locations of the nodes are given using 3D coordinates. Results are supported using ns-3 simulator. Results from simulation are consistent with the obtained results from mathematical model with less than 10% error.

  1. Identifying Controlling Nodes in Neuronal Networks in Different Scales

    Science.gov (United States)

    Tang, Yang; Gao, Huijun; Zou, Wei; Kurths, Jürgen

    2012-01-01

    Recent studies have detected hubs in neuronal networks using degree, betweenness centrality, motif and synchronization and revealed the importance of hubs in their structural and functional roles. In addition, the analysis of complex networks in different scales are widely used in physics community. This can provide detailed insights into the intrinsic properties of networks. In this study, we focus on the identification of controlling regions in cortical networks of cats’ brain in microscopic, mesoscopic and macroscopic scales, based on single-objective evolutionary computation methods. The problem is investigated by considering two measures of controllability separately. The impact of the number of driver nodes on controllability is revealed and the properties of controlling nodes are shown in a statistical way. Our results show that the statistical properties of the controlling nodes display a concave or convex shape with an increase of the allowed number of controlling nodes, revealing a transition in choosing driver nodes from the areas with a large degree to the areas with a low degree. Interestingly, the community Auditory in cats’ brain, which has sparse connections with other communities, plays an important role in controlling the neuronal networks. PMID:22848475

  2. [The validity of the sentinel node concept in gastrointestinal cancers].

    Science.gov (United States)

    Kitagawa, Y; Fujii, H; Mukai, M; Ando, N; Kubota, T; Ikeda, T; Ohgami, M; Watanabe, M; Otani, Y; Ozawa, S; Hasegawa, H; Furukawa, T; Nakahara, T; Kubo, A; Kumai, K; Kitajima, M

    2000-03-01

    Although the sentinel node concept has been validated and clinically applied to breast cancer and malignant melanoma, its clinical significance in other solid tumors has not been thoroughly investigated. With regard to gastrointestinal (GI) cancers in particular, our surgeons have been cautious because of the high frequency of skip metastasis and the complicated lymphatic system in the GI tract. We would like to emphasize that so-called skip metastasis has been defined according to anatomic classification of regional lymph nodes and that the lymphatic drainage route must be patient or lesion specific. To test the validity and feasibility of this concept in GI cancers, we have established a radio-guided intraoperative sentinel node navigation system using preoperative endoscopic submucosal injection of radioactive tracer followed by intra-operative gamma-probing. In 131 patients with GI cancers (esophagus: 22, stomach: 71, colorectum: 38), the detection rate of sentinel nades was 91% and overall diagnostic accuracy of lymph node metastasis by sentinel node status was 97%. Initial results suggest further investigation of this procedure as an accurate staging and a minimally invasive approach to early GI cancers.

  3. Detecting Boundary Nodes and Coverage Holes in Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Li-Hui Zhao

    2016-01-01

    Full Text Available The emergence of coverage holes in wireless sensor networks (WSNs means that some special events have broken out and the function of WSNs will be seriously influenced. Therefore, the issues of coverage holes have attracted considerable attention. In this paper, we focus on the identification of boundary nodes and coverage holes, which is crucially important to preventing the enlargement of coverage holes and ensuring the transmission of data. We define the problem of coverage holes and propose two novel algorithms to identify the coverage holes in WSNs. The first algorithm, Distributed Sector Cover Scanning (DSCS, can be used to identify the nodes on hole borders and the outer boundary of WSNs. The second scheme, Directional Walk (DW, can locate the coverage holes based on the boundary nodes identified with DSCS. We implement the algorithms in various scenarios and fully evaluate their performance. The simulation results show that the boundary nodes can be accurately detected by DSCS and the holes enclosed by the detected boundary nodes can be identified by DW. The comparisons confirm that the proposed algorithms outperform the existing ones.

  4. Wireless sensor node for detection of freight train derailment

    Science.gov (United States)

    Costa, Andrea; Milani, Damiano; Resta, Ferruccio; Tomasini, Gisella

    2016-04-01

    The target of the research activity presented in this paper is to design, to realize and to test an autonomous sensor node able to measure the accelerations in correspondence of the axle box of a freight train. The final goal of the sensor is to identify the derailment conditions by observing the variations in the spectra of the box accelerations, around the frequencies associated to the wheel revolution and its multiples. The sensor node embeds an accelerometer, a microprocessor, a transmission system, a piezoelectric bimorph energy harvester and an integrated circuit for managing the power distribution to each component of the node. In particular, a mechanical filter to be applied to the node was specifically designed to increment the energy recovered by the harvester and to filter out the high frequency components of the axle-box acceleration, allowing the use of a more sensitive accelerometer. The harvesting system was setup by means of laboratory tests carried out with an electromechanical shaker and the sensor node was finally tested through field tests on freight trains.

  5. Network structure exploration in networks with node attributes

    Science.gov (United States)

    Chen, Yi; Wang, Xiaolong; Bu, Junzhao; Tang, Buzhou; Xiang, Xin

    2016-05-01

    Complex networks provide a powerful way to represent complex systems and have been widely studied during the past several years. One of the most important tasks of network analysis is to detect structures (also called structural regularities) embedded in networks by determining group number and group partition. Most of network structure exploration models only consider network links. However, in real world networks, nodes may have attributes that are useful for network structure exploration. In this paper, we propose a novel Bayesian nonparametric (BNP) model to explore structural regularities in networks with node attributes, called Bayesian nonparametric attribute (BNPA) model. This model does not only take full advantage of both links between nodes and node attributes for group partition via shared hidden variables, but also determine group number automatically via the Bayesian nonparametric theory. Experiments conducted on a number of real and synthetic networks show that our BNPA model is able to automatically explore structural regularities in networks with node attributes and is competitive with other state-of-the-art models.

  6. Deployment of check-in nodes in complex networks

    Science.gov (United States)

    Jiang, Zhong-Yuan; Ma, Jian-Feng

    2017-01-01

    In many real complex networks such as the city road networks and highway networks, vehicles often have to pass through some specially functioned nodes to receive check-in like services such as gas supplement at gas stations. Based on existing network structures, to guarantee every shortest path including at least a check-in node, the location selection of all check-in nodes is very essential and important to make vehicles to easily visit these check-in nodes, and it is still remains an open problem in complex network studies. In this work, we aim to find possible solutions for this problem. We first convert it into a set cover problem which is NP-complete and propose to employ the greedy algorithm to achieve an approximate result. Inspired by heuristic information of network structure, we discuss other four check-in node location deployment methods including high betweenness first (HBF), high degree first (HDF), random and low degree first (LDF). Finally, we compose extensive simulations in classical scale-free networks, random networks and real network models, and the results can well confirm the effectiveness of the greedy algorithm. This work has potential applications into many real networks.

  7. Lymph node metastasis in the biliary tract carcinoma: CT evaluation

    International Nuclear Information System (INIS)

    Lee, Byung Hee; Lee, Ah Ra; Kim, Kie Hwan; Do, Young Soo; Chin, Soo Yil

    1994-01-01

    The primary biliary carcinoma is usually unresectable at presentation, because of early lymphatic spread. To determine the incidence and the spread pattern of lymph node metastases according to the location of the primary tumor, we analyzed the CT scans of the patients with primary biliary adenocarcinoma. We reviewed the CT scans of 92 patients with pathologically proven primary biliary adenocacinima, including 45 peripheral cholangiocarcinomas, 22 hilar cholangiocarcinomas, 18 gallbladder carcinomas, and 7 common bile duct carcinomas. Positive adenopathy was diagnosed when the node exceeded 10 mm in short axis. The overall incidence of nodal metastases was 59.8% (55/92); 66.7% in peripheral cholangiocarcinoma, 54.5% in hilar cholangiocarcinoma, 55.6% in gallbladder carcinoma, and 42.9% in common bile duct carcinoma. The most commonly involved nodal group was the lesser omentum, followed by the celiac, periaortic, and peripancreatic group. The phrenic node group was only involved in the cases with the peripheral or hilar cholangiocarcinoma. The primary biliary carcinoma has a high incidence of lymph node metastases at the time of diagnosis, and shows different nodal spread pattern according to the location of the primary tumor. Involvement of the phrenic node was limited to the peripheral and hilar cholangiocarcinoma

  8. Lymph node metastasis in the biliary tract carcinoma: CT evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Byung Hee; Lee, Ah Ra; Kim, Kie Hwan; Do, Young Soo; Chin, Soo Yil [Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    1994-07-15

    The primary biliary carcinoma is usually unresectable at presentation, because of early lymphatic spread. To determine the incidence and the spread pattern of lymph node metastases according to the location of the primary tumor, we analyzed the CT scans of the patients with primary biliary adenocarcinoma. We reviewed the CT scans of 92 patients with pathologically proven primary biliary adenocacinima, including 45 peripheral cholangiocarcinomas, 22 hilar cholangiocarcinomas, 18 gallbladder carcinomas, and 7 common bile duct carcinomas. Positive adenopathy was diagnosed when the node exceeded 10 mm in short axis. The overall incidence of nodal metastases was 59.8% (55/92); 66.7% in peripheral cholangiocarcinoma, 54.5% in hilar cholangiocarcinoma, 55.6% in gallbladder carcinoma, and 42.9% in common bile duct carcinoma. The most commonly involved nodal group was the lesser omentum, followed by the celiac, periaortic, and peripancreatic group. The phrenic node group was only involved in the cases with the peripheral or hilar cholangiocarcinoma. The primary biliary carcinoma has a high incidence of lymph node metastases at the time of diagnosis, and shows different nodal spread pattern according to the location of the primary tumor. Involvement of the phrenic node was limited to the peripheral and hilar cholangiocarcinoma.

  9. Proteomic biomarkers predicting lymph node involvement in serum of cervical cancer patients. Limitations of SELDI-TOF MS

    Directory of Open Access Journals (Sweden)

    Van Gorp Toon

    2012-06-01

    Full Text Available Abstract Background Lymph node status is not part of the staging system for cervical cancer, but provides important information for prognosis and treatment. We investigated whether lymph node status can be predicted with proteomic profiling. Material & methods Serum samples of 60 cervical cancer patients (FIGO I/II were obtained before primary treatment. Samples were run through a HPLC depletion column, eliminating the 14 most abundant proteins ubiquitously present in serum. Unbound fractions were concentrated with spin filters. Fractions were spotted onto CM10 and IMAC30 surfaces and analyzed with surface-enhanced laser desorption time of flight (SELDI-TOF mass spectrometry (MS. Unsupervised peak detection and peak clustering was performed using MASDA software. Leave-one-out (LOO validation for weighted Least Squares Support Vector Machines (LSSVM was used for prediction of lymph node involvement. Other outcomes were histological type, lymphvascular space involvement (LVSI and recurrent disease. Results LSSVM models were able to determine LN status with a LOO area under the receiver operating characteristics curve (AUC of 0.95, based on peaks with m/z values 2,698.9, 3,953.2, and 15,254.8. Furthermore, we were able to predict LVSI (AUC 0.81, to predict recurrence (AUC 0.92, and to differentiate between squamous carcinomas and adenocarcinomas (AUC 0.88, between squamous and adenosquamous carcinomas (AUC 0.85, and between adenocarcinomas and adenosquamous carcinomas (AUC 0.94. Conclusions Potential markers related with lymph node involvement were detected, and protein/peptide profiling support differentiation between various subtypes of cervical cancer. However, identification of the potential biomarkers was hampered by the technical limitations of SELDI-TOF MS.

  10. Enabling Electric Propulsion for Flight

    Science.gov (United States)

    Ginn, Starr Renee

    2015-01-01

    Team Seedling project AFRC and LaRC 31ft distributed electric propulsion wing on truck bed up 75 miles per hour for coefficient of lift validation. Convergent Aeronautic Solutions project, sub-project Convergent Electric Propulsion Technologies AFRC, LaRC and GRC, re-winging a 4 passenger Tecnam aircraft with a 31ft distributed electric propulsion wing. Advanced Air Transport Technologies (Fixed Wing), Hybrid Electric Research Theme, developing a series hybrid ironbird and flight sim to study integration and performance challenges in preparation for a 1-2 MW flight project.

  11. CHANGES IN FLIGHT TRAINEE PERFORMANCE FOLLOWING SYNTHETIC HELICOPTER FLIGHT TRAINING.

    Science.gov (United States)

    CARO, PAUL W., JR.; ISLEY, ROBERT N.

    A STUDY WAS CONDUCTED AT THE U.S. ARMY PRIMARY HELICOPTER SCHOOL, FORT WOLTERS, TEXAS, TO DETERMINE WHETHER THE USE OF A HELICOPTER TRAINING DEVICE WOULD IMPROVE STUDENT PERFORMANCE DURING SUBSEQUENT HELICOPTER CONTACT FLIGHT TRAINING. SUBJECTS WERE TWO EXPERIMENTAL GROUPS AND TWO CONTROL GROUPS OF WARRANT OFFICER CANDIDATES ENROLLED FOR A…

  12. Flight Attendant Fatigue: A Quantitative Review of Flight Attendant Comments

    Science.gov (United States)

    2011-10-01

    Hellesoy, 1994; Hunt & Space, 1994; Nagda & Koontz , 2003; Nesthus et al., 2007; Rayman, 1997; Smolensky, Lee, Mott, & Colligan, 1982; Tashkin...www.boeing. com/commercial/cabinair/ventilation.pdf Nagda, N.L., & Koontz , M.D. (2003). Review of studies on flight attendant health and comfort in

  13. Orion Exploration Flight Test Post-Flight Inspection and Analysis

    Science.gov (United States)

    Miller, J. E.; Berger, E. L.; Bohl, W. E.; Christiansen, E. L.; Davis, B. A.; Deighton, K. D.; Enriquez, P. A.; Garcia, M. A.; Hyde, J. L.; Oliveras, O. M.

    2017-01-01

    The principal mechanism for developing orbital debris environment models, is to make observations of larger pieces of debris in the range of several centimeters and greater using radar and optical techniques. For particles that are smaller than this threshold, breakup and migration models of particles to returned surfaces in lower orbit are relied upon to quantify the flux. This reliance on models to derive spatial densities of particles that are of critical importance to spacecraft make the unique nature of the EFT-1's return surface a valuable metric. To this end detailed post-flight inspections have been performed of the returned EFT-1 backshell, and the inspections identified six candidate impact sites that were not present during the pre-flight inspections. This paper describes the post-flight analysis efforts to characterize the EFT-1 mission craters. This effort included ground based testing to understand small particle impact craters in the thermal protection material, the pre- and post-flight inspection, the crater analysis using optical, X-ray computed tomography (CT) and scanning electron microscope (SEM) techniques, and numerical simulations.

  14. Completion Dissection or Observation for Sentinel-Node Metastasis in Melanoma

    NARCIS (Netherlands)

    Faries, M. B.; Thompson, J. F.; Cochran, A. J.; Andtbacka, R. H.; Mozzillo, N; Zager, Jonathan S.; Jahkola, T.; Bowles, T. L.; Testori, Alessandro; Beitsch, P. D.; Hoekstra, H. J.; Moncrieff, M.; Ingvar, C.; Wouters, M. W. J. M.; Sabel, M. S.; Levine, E. A.; Agnese, D.; Henderson, M.; Dummer, R; Rossi, C. R.; Neves, R. I.; Trocha, S. D.; Wright, Sara F.; Byrd, D. R.; Matter, M.; Hsueh, E.; MacKenzie-Ross, A.; Johnson, B. D.; Terheyden, P.; Berger, A. C.; Huston, T. L.; Wayne, J. D.; Smithers, B. Mark; Neuman, H. B.; Schneebaum, S.; Gershenwald, Jeffrey E.; Ariyan, C. E.; Desai, D. C.; Jacobs, L.; McMasters, K. M.; Gesierich, A.; Hersey, P.; Bines, S. D.; Kane, Michael J.; Barth, R. J.; McKinnon, J. G.; Farma, J. M.; Schultz, B. E.; Vidal-Sicart, S.; Hoefer, R. A.; Lewis, David J. M.; Scheri, R.; Kelley, M. C.; Nieweg, O. E.; Noyes, R. D.; Hoon, D. S. B.; Wang, H. -J.; Elashoff, D. A.; Elashoff, R. M.

    2017-01-01

    BACKGROUND Sentinel-lymph-node biopsy is associated with increased melanoma-specific survival (i.e., survival until death from melanoma) among patients with node-positive intermediate-thickness melanomas (1.2 to 3.5 mm). The value of completion lymph-node dissection for patients with sentinel-node

  15. Clearance Analysis of Node 3 Aft CBM to the Stowed FGB Solar Array

    Science.gov (United States)

    Liddle, Donn

    2014-01-01

    measured within an accuracy of about 1 in. in each axis relative to the ISS Analysis Coordinate System (ISSACS). In October 2011, a proposed image-acquisition plan was drafted by ISAG and released for review. The ISS Robotics flight control team (ROBO) proposed minor changes to SPDM positions 1 and 4 to meet ISS proximity requirements. The updated image acquisition plan and draft chit were presented to and approved by the Systems Working Group (SWG) November 18 and were sent to the Vehicle Configuration Board (VCB) in early December 2011. Working with ROBO on 3 successive days (February 21, 22, and 23), ISAG collected 161 images of the ISS. Approximately 40 images were collected from each of the four different SSRMS/SPDM positions, with each set mapping the region from the Node 3 end cone, across Node 1, along the forward port side portion of the FGB, and out the port side FGB solar arrays. From this imagery, the best 80 images were selected for use in the analysis. The images were radiometrically enhanced to improve color and contrast and loaded into the FotoG analysis software along with the camera parameters and control data, which consisted of the coordinates for 54 handrail attachment bolts on the aft face of Node 3, in the ISSACS coordinate system. The results of this analysis produced the measured coordinates of 116 points distributed across the face of the FGB solar array panels (see figure 3) along with propagated uncertainty estimates in each coordinate axis. These results were sent to the ISS Vehicle Configuration Office, which sent them to the Configuration Analysis Modeling and Mass Properties (CAMMP) team for comparison with the Russian-provided CAD model for the retracted FGB solar arrays. The CAMMP analysis unexpectedly showed that the measured location of the port FGB solar array was up to 41-in. further outboard than the design and was slightly twisted about its rotational axis. The unexpected comparison results produced some initial concern regarding the

  16. Direct Visual Editing of Node Attributes in Graphs

    Directory of Open Access Journals (Sweden)

    Christian Eichner

    2016-10-01

    Full Text Available There are many expressive visualization techniques for analyzing graphs. Yet, there is only little research on how existing visual representations can be employed to support data editing. An increasingly relevant task when working with graphs is the editing of node attributes. We propose an integrated visualize-and-edit approach to editing attribute values via direct interaction with the visual representation. The visualize part is based on node-link diagrams paired with attribute-dependent layouts. The edit part is as easy as moving nodes via drag-and-drop gestures. We present dedicated interaction techniques for editing quantitative as well as qualitative attribute data values. The benefit of our novel integrated approach is that one can directly edit the data while the visualization constantly provides feedback on the implications of the data modifications. Preliminary user feedback indicates that our integrated approach can be a useful complement to standard non-visual editing via external tools.

  17. Lymph node hemangioma in one-humped camel

    Directory of Open Access Journals (Sweden)

    M.A. Aljameel

    2015-12-01

    Full Text Available Hemangioma is a benign tumor of blood and lymphatic vessels. It is common in skin, mucosa and soft tissues, and its occurrence in lymph nodes is extremely rare. A 10 year-old she-camel was slaughtered at Nyala slaughterhouse, South Darfur State, Sudan. Grossly, the carcass was emaciated. The left ventral superficial cervical lymph node was enlarged, hard on palpation and protruded outside the body. Its cut surface was dark red in color and measured (18 cm in diameter. Histopathologically, the sections revealed vascular masses were composed of non-encapsulated clusters of small and medium sized with thick and thin-walled, filled with blood, separated by courageous stroma and surrounded by closely packed proliferating capillaries. To the best of our knowledge, this is the first record of the left ventral superficial cervical lymph node hemangioma in a camel in the Sudan.

  18. Minimization of heat slab nodes with higher order boundary conditions

    International Nuclear Information System (INIS)

    Solbrig, C.W.

    1992-01-01

    The accuracy of a numerical solution can be limited by the numerical approximation to the boundary conditions rather than the accuracy of the equations which describe the interior. The study presented in this paper compares the results from two different numerical formulations of the convective boundary condition on the face of a heat transfer slab. The standard representation of the boundary condition in a test problem yielded an unacceptable error even when the heat transfer slab was partitioned into over 300 nodes. A higher order boundary condition representation was obtained by using a second order approximation for the first derivative at the boundary and combining it with the general equation used for inner nodes. This latter formulation produced reasonable results when as few as ten nodes were used

  19. Optimal Node Placement in Underwater Wireless Sensor Networks

    KAUST Repository

    Felamban, M.

    2013-03-25

    Wireless Sensor Networks (WSN) are expected to play a vital role in the exploration and monitoring of underwater areas which are not easily reachable by humans. However, underwater communication via acoustic waves is subject to several performance limitations that are very different from those used for terresstrial networks. In this paper, we investigate node placement for building an initial underwater WSN infrastructure. We formulate this problem as a nonlinear mathematical program with the objective of minimizing the total transmission loss under a given number of sensor nodes and targeted coverage volume. The obtained solution is the location of each node represented via a truncated octahedron to fill out the 3D space. Experiments are conducted to verify the proposed formulation, which is solved using Matlab optimization tool. Simulation is also conducted using an ns-3 simulator, and the simulation results are consistent with the obtained results from mathematical model with less than 10% error.

  20. A solar charge and discharge controller for wireless sensor nodes

    Science.gov (United States)

    Dang, Yibo; Shen, Shu

    2018-02-01

    Aiming at the energy supply problem that restricts the life of wireless sensor nodes, a solar energy charge and discharge controller suitable for wireless sensor nodes is designed in this paper. A Microcontroller is used as the core of the solar charge and discharge controller. The software of the solar charge and discharge controller adopts the C language to realize the program of the main control module. Firstly, the function of monitoring solar panel voltage and lithium battery voltage are simulated by Protel software, and the charge time is tested in cloudy and overcast outdoor environment. The results of the experiment show that our controller meets the power supply demand of wireless sensor nodes.

  1. Angiosarcoma of the Thyroid and Regional Lymph Node Metastasis

    Directory of Open Access Journals (Sweden)

    Lutfi Dogan

    2013-10-01

    Full Text Available Thyroid angiosarcomas are typically infiltrative and large tumors with very similar clinical findings of anaplastic carcinoma of thyroid. Early hematogenous metastasis is very frequent, but regional lymph node metastasis is quite rare. We present a case of angiosarcoma of the thyroid gland in a 68 years old man with regional lymph node metastasis. Total thyroidectomy with right modified radical neck dissection was applied. Four out of 19 lymph nodes dissected were seen to contain metastasis. Metastatic tumor was composed of sarcomatous areas containing large numbers of blood filled clefts. There after the surgery PET-CT was performed and multiple metastatic involvements were reported. Thyroid angiosarcomas are completely different tumors from angiomatoid anaplastic carcinomas. Longer survival with these tumors is only possible with agressive surgery and in case of regional LN metastasis, neck dissection should be done.

  2. XPath Node Selection over Grammar-Compressed Trees

    Directory of Open Access Journals (Sweden)

    Sebastian Maneth

    2013-11-01

    Full Text Available XML document markup is highly repetitive and therefore well compressible using grammar-based compression. Downward, navigational XPath can be executed over grammar-compressed trees in PTIME: the query is translated into an automaton which is executed in one pass over the grammar. This result is well-known and has been mentioned before. Here we present precise bounds on the time complexity of this problem, in terms of big-O notation. For a given grammar and XPath query, we consider three different tasks: (1 to count the number of nodes selected by the query, (2 to materialize the pre-order numbers of the selected nodes, and (3 to serialize the subtrees at the selected nodes.

  3. Accuracy of abdominal lymph node scintigraphy in tumor diagnostics

    International Nuclear Information System (INIS)

    Kucharczyk, D.

    1978-01-01

    In view of the diagnostical correspondence between lymph node scintigraphy and X-ray lymphograpy, this dissertation, which is based on 110 systematic comparative evaluations, examines the diagnostical weight of the scintigraphic criteria for tumor growth, discusses diagnostical discrepancies and confirms the efficacy of lymph node scintigraphy in detecting malignomas. In discussing the diagnostical results in the light of previous experience, the shortcomings of the nuclear medical method in tumor diagnostics are shown to be attributable to the uncertainty of the individual scintigraphic criteria. Owing to the variability of the lymph node system as to topography, anatomy and retention rate and the fact that it cannot morphologically be well differentiated in the scintigram, X-ray lymphography to verify the scintigraphic result and preclude misinterpretation remains an indispensable measure. (orig.) [de

  4. Lymph Node Assessment in Endometrial Cancer: Towards Personalized Medicine

    Directory of Open Access Journals (Sweden)

    Fabien Vidal

    2013-01-01

    Full Text Available Endometrial cancer (EC is the most common malignancy of the female reproductive tract and is increasing in incidence. Lymphovascular invasion and lymph node (LN status are strong predictive factors of recurrence. Therefore, the determination of the nodal status of patients is mandatory to optimally tailor adjuvant therapies and reduce local and distant recurrences. Imaging modalities do not yet allow accurate lymph node staging; thus pelvic and aortic lymphadenectomies remain standard staging procedures. The clinical data accumulated recently allow us to define low- and high-risk patients based on pre- or peroperative findings that will allow the clinician to stratify the patients for their need of lymphadenectomies. More recently, several groups have been introducing sentinel node mapping with promising results as an alternative to complete lymphadenectomy. Finally, the use of peroperative algorithm for risk determination could improve patient's staging with a reduction of lymphadenectomy-related morbidity.

  5. Analysis of Network Vulnerability Under Joint Node and Link Attacks

    Science.gov (United States)

    Li, Yongcheng; Liu, Shumei; Yu, Yao; Cao, Ting

    2018-03-01

    The security problem of computer network system is becoming more and more serious. The fundamental reason is that there are security vulnerabilities in the network system. Therefore, it’s very important to identify and reduce or eliminate these vulnerabilities before they are attacked. In this paper, we are interested in joint node and link attacks and propose a vulnerability evaluation method based on the overall connectivity of the network to defense this attack. Especially, we analyze the attack cost problem from the attackers’ perspective. The purpose is to find the set of least costs for joint links and nodes, and their deletion will lead to serious network connection damage. The simulation results show that the vulnerable elements obtained from the proposed method are more suitable for the attacking idea of the malicious persons in joint node and link attack. It is easy to find that the proposed method has more realistic protection significance.

  6. Vision based flight procedure stereo display system

    Science.gov (United States)

    Shen, Xiaoyun; Wan, Di; Ma, Lan; He, Yuncheng

    2008-03-01

    A virtual reality flight procedure vision system is introduced in this paper. The digital flight map database is established based on the Geographic Information System (GIS) and high definitions satellite remote sensing photos. The flight approaching area database is established through computer 3D modeling system and GIS. The area texture is generated from the remote sensing photos and aerial photographs in various level of detail. According to the flight approaching procedure, the flight navigation information is linked to the database. The flight approaching area vision can be dynamic displayed according to the designed flight procedure. The flight approaching area images are rendered in 2 channels, one for left eye images and the others for right eye images. Through the polarized stereoscopic projection system, the pilots and aircrew can get the vivid 3D vision of the flight destination approaching area. Take the use of this system in pilots preflight preparation procedure, the aircrew can get more vivid information along the flight destination approaching area. This system can improve the aviator's self-confidence before he carries out the flight mission, accordingly, the flight safety is improved. This system is also useful in validate the visual flight procedure design, and it helps to the flight procedure design.

  7. Importance of Metastatic Lymph Node Ratio in Non-Metastatic, Lymph Node-Invaded Colon Cancer: A Clinical Trial

    Science.gov (United States)

    Isik, Arda; Peker, Kemal; Firat, Deniz; Yilmaz, Bahri; Sayar, Ilyas; Idiz, Oguz; Cakir, Coskun; Demiryilmaz, Ismail; Yilmaz, Ismayil

    2014-01-01

    Background The aim of this study was to evaluate the prognostic importance of the metastatic lymph node ratio for stage III colon cancer patients and to find a cut-off value at which the overall survival and disease-free survival change. Material/Methods Patients with pathological stage III colon cancer were retrospectively evaluated for: age; preoperative values of Crp, Cea, Ca 19-9, and Afp; pathologic situation of vascular, perineural, lymphatic, and serosal involvement; and metastatic lymph node ratio values were calculated. Results The study included 58 stage III colon cancer patients: 20 (34.5%) females and 38 (65.5%) males were involved in the study. Multivariate analysis was applied to the following variables to evaluate significance for overall survival and disease-free survival: age, Crp, Cea, perineural invasion, and metastatic lymph node ratio. The metastatic lymph node ratio (<0.25 or ≥0.25) is the only independent variable significant for overall and disease-free survival. Conclusions Metastatic lymph node ratio is an ideal prognostic marker for stage III colon cancer patients, and 0.25 is the cut-off value for prognosis. PMID:25087904

  8. Distribution of Porcine Haemal Nodes and Morphological Variations in the Haemal Nodes of Cattle and West African Dwarf Goats

    Directory of Open Access Journals (Sweden)

    Anietie Francis UDOUMOH

    2016-12-01

    Full Text Available Apparently healthy, non-lactating, non-gravid adult large white pigs (15, adult cattle (10 and adult West African Dwarf (WAD goats of either genders were used to investigate the morphology of haemal nodes using gross anatomical and histological techniques. The results demonstrated that the haemal nodes of pigs occurred in the thoracic, abdominal and pelvic regions along the course of blood vessels. The ranges of the longest diameters of the dark brown organs were 6.1 – 30.3 cm in pigs, 4.1 – 18.7 cm in cattle and 2.7 – 8.2 cm in WAD goats. Bovine haemal nodes showed cortical and medullary parenchymal areas, with the cortex demonstrating primary and secondary lymphoid follicles in a circumferential fashion. The medulla showed blood filled medullary sinusoids and medullary cords. In WAD goat, the reticular cells and smooth muscle cells of the capsule were oriented in different directions and the subcapsular, cortical and medullary sinusoids exhibited erythrocytes in pockets. In conclusion, the present study has provided information on the distribution of haemal nodes in pigs as well as other unique morphological features of cattle and WAD goat haemal nodes that could aid their identification and suggest their roles in the body.

  9. Next Generation Flight Displays Using HTML5

    Science.gov (United States)

    Greenwood, Brian

    2016-01-01

    The Human Integrated Vehicles and Environments (HIVE) lab at Johnson Space Center (JSC) is focused on bringing together inter-disciplinary talent to design and integrate innovative human interface technologies for next generation manned spacecraft. As part of this objective, my summer internship project centered on an ongoing investigation in to building flight displays using the HTML5 standard. Specifically, the goals of my project were to build and demo "flight-like" crew and wearable displays as well as create a webserver for live systems being developed by the Advanced Exploration Systems (AES) program. In parallel to my project, a LabVIEW application, called a display server, was created by the HIVE that uses an XTCE (XML (Extensible Markup Language) Telemetry and Command Exchange) parser and CCSDS (Consultative Committee for Space Data System) space packet decoder to translate telemetry items sent by the CFS (Core Flight Software) over User Datagram Protocol (UDP). It was the webserver's job to receive these UDP messages and send them to the displays. To accomplish this functionality, I utilized Node.js and the accompanying Express framework. On the display side, I was responsible for creating the power system (AMPS) displays. I did this by using HTML5, CSS and JavaScript to create web pages that could update and change dynamically based on the data they received from the webserver. At this point, I have not started on the commanding, being able to send back to the CFS, portion of the displays but hope to have this functionality working by the completion of my internship. I also created a way to test the webserver's functionality without the display server by making a JavaScript application that read in a comma-separate values (CSV) file and converted it to XML which was then sent over UDP. One of the major requirements of my project was to build everything using as little preexisting code as possible, which I accomplished by only using a handful of Java

  10. Para-aortic lymph node radiation in advanced cervical cancer

    International Nuclear Information System (INIS)

    Emami, B.; Watring, W.G.; Tak, W.; Anderson, B.; Piro, A.J.

    1980-01-01

    Thirty-six patients with advanced carcinoma of the uterine cervix and with iliac or para-aortic nodes interpreted as un-equivocally positive on lymphangiography have received radiation therapy to the para-aortic area at the Department of Therapeutic Radiology at Tufts-New England Medical Center Hospital. Of 29 patients who received para-aortic area irradiation as part of their initial treatment, local control was achieved in 18 patients (62%). Overall, four patients developed major complications requiring surgical intervention. Detailed results and our current pre-treatment evaluation policy including lymphangiography, percutaneous needle biopsy and selective extra-peritoneal lymph node biopsy will be discussed

  11. CT diagnosis of abdominal lymph node metastases in hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, T; Nakamura, H; Choi, S; Morimoto, K; Kawamoto, S; Hori, S; Tokunaga, K; Yoskioka, H; Kuroda, C

    1985-08-01

    CT scanning is useful for diagnosing abdominal lymph node metastasis. Using this technique, histologically confirmed abdominal lymph node metastases were detected in nine of 49 patients (33 autopsy cases and 16 laparotomy cases) with hepatocellular carcinoma (hepatoma). Among the 49 patients, three had periportal (6.1%), six peripancreatic (12.2.%) and six para-aortic adenopathies (12.2%). Two of the patients had adenopathy at all three sites. Retrospectively, CT detected two periportal, four peripancreatic and all six para-aortic adenopathies. Most of the hepatomas with adenopathy showed infiltrative growth; tumour thrombosis of the portal vein was a common complication.

  12. Influence of Elastic Anisotropy on Extended Dislocation Nodes

    Energy Technology Data Exchange (ETDEWEB)

    Pettersson, B

    1971-09-15

    The interaction forces between the partial dislocations forming an extended dislocation node are calculated using elasticity theory for anisotropic media.s are carried out for nodes of screw, edge and mixed character in Ag, which has an anisotropy ratio A equal to 3, and in a hypothetic material with A = 1 and the same shear modulus as Ag. The results are compared with three previous theories using isotropic elasticity theory. As expected, in Ag the influence of anisotropy is of the same order as the uncertainty due to the dislocation core energy

  13. Node Discovery and Interpretation in Unstructured Resource-Constrained Environments

    DEFF Research Database (Denmark)

    Gechev, Miroslav; Kasabova, Slavyana; Mihovska, Albena D.

    2014-01-01

    for the discovery, linking and interpretation of nodes in unstructured and resource-constrained network environments and their interrelated and collective use for the delivery of smart services. The model is based on a basic mathematical approach, which describes and predicts the success of human interactions...... in the context of long-term relationships and identifies several key variables in the context of communications in resource-constrained environments. The general theoretical model is described and several algorithms are proposed as part of the node discovery, identification, and linking processes in relation...

  14. Empowering smartphone users with sensor node for air quality measurement

    Science.gov (United States)

    Oletic, Dinko; Bilas, Vedran

    2013-06-01

    We present an architecture of a sensor node developed for use with smartphones for participatory sensing of air quality in urban environments. Our solution features inexpensive metal-oxide semiconductor gas sensors (MOX) for measurement of CO, O3, NO2 and VOC, along with sensors for ambient temperature and humidity. We focus on our design of sensor interface consisting of power-regulated heater temperature control, and the design of resistance sensing circuit. Accuracy of the sensor interface is characterized. Power consumption of the sensor node is analysed. Preliminary data obtained from the CO gas sensors in laboratory conditions and during the outdoor field-test is shown.

  15. Empowering smartphone users with sensor node for air quality measurement

    International Nuclear Information System (INIS)

    Oletic, Dinko; Bilas, Vedran

    2013-01-01

    We present an architecture of a sensor node developed for use with smartphones for participatory sensing of air quality in urban environments. Our solution features inexpensive metal-oxide semiconductor gas sensors (MOX) for measurement of CO, O 3 , NO 2 and VOC, along with sensors for ambient temperature and humidity. We focus on our design of sensor interface consisting of power-regulated heater temperature control, and the design of resistance sensing circuit. Accuracy of the sensor interface is characterized. Power consumption of the sensor node is analysed. Preliminary data obtained from the CO gas sensors in laboratory conditions and during the outdoor field-test is shown.

  16. Microfluidic ultrasonic particle separators with engineered node locations and geometries

    Science.gov (United States)

    Rose, Klint A.; Fisher, Karl A.; Wajda, Douglas A.; Mariella, Jr., Raymond P.; Bailey, Christopher; Dehlinger, Dietrich; Shusteff, Maxim; Jung, Byoungsok; Ness, Kevin D.

    2016-04-26

    An ultrasonic microfluidic system includes a separation channel for conveying a sample fluid containing small particles and large particles, flowing substantially parallel, adjacent to a recovery fluid, with which it is in contact. An acoustic transducer produces an ultrasound standing wave, that generates a pressure field having at least one node of minimum pressure amplitude. An acoustic extension structure is located proximate to said separation channel for positioning said acoustic node off center in said acoustic area and concentrating the large particles in said recovery fluid stream.

  17. Metastasis in the subcarinal lymph node with unknown primary tumor

    DEFF Research Database (Denmark)

    Eckardt, J.; Olsen, K. E.; Petersen, H.

    2011-01-01

    -differentiated squamous cell carcinoma but no primary tumor was visible on PET-computed tomography. Because of his previous lymphoma the patient was scheduled for mediastinoscopy where the diagnosis was confirmed. Subsequent gastroscopy was normal and a right-sided thoracotomy showed no evidence of cancer elsewhere, only...... an inoperable metastasis in a subcarinal lymph node which infiltrated the trachea, esophagus and aorta. Such isolated squamous cell carcinoma in a subcarinal lymph node without a primary tumor despite invasive work-up has not been reported before....

  18. Cavitatory mesenteric lymph node syndrome: A rare entity

    International Nuclear Information System (INIS)

    Vibhuti; Vishal, Kalia; Gill, Anakhvir

    2010-01-01

    Celiac disease is a gluten sensitive enteropathy that involves an abnormal immunological response to glutens in wheat, rye etc. It predominantly involves the small intestinal mucosa, though, extra luminal manifestations can also occur. One rare extraluminal manifestation is cavitatory mesenteric lymph node syndrome. It occurs in refractory celiac disease and is associated with poor prognosis due to various complications. The diagnosis is often made on imaging when cystic mesenteric lymph nodes with fat-fluid levels are seen and this can then be confirmed by histopathological examination. We recently had a typical case where we were able to make this diagnosis

  19. Transaction processing in the common node of a distributed function laboratory computer system

    International Nuclear Information System (INIS)

    Stubblefield, F.W.; Dimmler, D.G.

    1975-01-01

    A computer network architecture consisting of a common node processor for managing peripherals and files and a number of private node processors for laboratory experiment control is briefly reviewed. Central to the problem of private node-common node communication is the concept of a transaction. The collection of procedures and the data structure associated with a transaction are described. The common node properties assigned to a transaction and procedures required for its complete processing are discussed. (U.S.)

  20. STS-70 Post Flight Presentation

    Science.gov (United States)

    Peterson, Glen (Editor)

    1995-01-01

    In this post-flight overview, the flight crew of the STS-70 mission, Tom Henricks (Cmdr.), Kevin Kregel (Pilot), Major Nancy Currie (MS), Dr. Mary Ellen Weber (MS), and Dr. Don Thomas (MS), discuss their mission and accompanying experiments. Pre-flight, launch, and orbital footage is followed by the in-orbit deployment of the Tracking and Data Relay Satellite (TDRS) and a discussion of the following spaceborne experiments: a microgravity bioreactor experiment to grow 3D body-like tissue; pregnant rat muscular changes in microgravity; embryonic development in microgravity; Shuttle Amateur Radio Experiment (SAREX); terrain surface imagery using the HERCULES camera; and a range of other physiological tests, including an eye and vision test. Views of Earth include: tropical storm Chantal; the Nile River and Red Sea; lightning over Brazil. A three planet view (Earth, Mars, and Venus) was taken right before sunrise. The end footage shows shuttle pre-landing checkout, entry, and landing, along with a slide presentation of the flight.

  1. ALICE Time Of Flight Detector

    CERN Multimedia

    Alici, A

    2013-01-01

    Charged particles in the intermediate momentum range are identified in ALICE by the Time Of Flight (TOF) detector. The time measurement with the TOF, in conjunction with the momentum and track length measured by the tracking detector, is used to calculate the particle mass.

  2. Bat Flight and Zoonotic Viruses

    Centers for Disease Control (CDC) Podcasts

    2014-05-30

    Reginald Tucker reads an abridged version of the EID perspective Bat Flight and Zoonotic Viruses.  Created: 5/30/2014 by National Center for Emerging and Zoonotic Infectious Diseases (NCEZID).   Date Released: 6/2/2014.

  3. Centennial of Flight Educational Outreach

    Science.gov (United States)

    McCarthy, Marianne (Technical Monitor); Miller, Susan (Technical Monitor); Vanderpool, Celia

    2003-01-01

    The Centennial of Flight Education Outreach project worked with community partners to disseminate NASA Education materials and the Centennial of Flight CD-ROM as a vehicle to increase national awareness of NASA's Aerospace Education products, services and programs. The Azimuth Education Foundation and the Ninety Nines, an International Women Pilots Association, Inc. were chartered to conduct education outreach to the formal and informal educational community. The Dryden Education Office supported the development of a training and information distribution program that established a national group of prepared Centennial of Flight Ambassadors, with a mission of community education outreach. These Ambassadors are members of the Ninety Nines and through the Azimuth Foundation, they assisted the AECC on the national level to promote and disseminate Centennial of Flight and other educational products. Our objectives were to explore partnership outreach growth opportunities with consortium efforts between organizations. This project directly responded to the highlights of NASA s Implementation Plan for Education. It was structured to network, involve the community, and provide a solid link to active educators and current students with NASA education information. Licensed female pilots who live and work in local communities across the nation carried the link. This partnership has been extremely gratifying to all of those Ninety-Nines involved, and they eagerly look forward to further work opportunities.

  4. Cytogenic Investigations in Flight Personnel

    International Nuclear Information System (INIS)

    Wolf, G.; Obe, G.; Bergau, L.

    1999-01-01

    During long-distance flights at high altitudes flight personnel are exposed to cosmic radiation. In order to determine whether there are biological effects of such low dose radiation exposure in aircrew, chromosomal aberrations were investigated in 59 female cabin attendants and a matched control group of 31 members of station personnel. The mean number of dicentric chromosomes amounts to 1.3 (95% CI 1.0-1.6) per 1,000 cells in cabin attendants and 1.4 (95% CI 1.0-1.9) per 1,000 cells in controls. In an additional control group of 56 female clerks from Berlin the mean frequency of dicentric chromosomes was 1.3 (95% CI 1.0-1.6). Neither in dicentric frequency and distribution nor in other aberrations was a significant difference between the groups of flight and station personnel found. The high frequency of multi-aberrant cells was remarkable in flight personnel as well as in station personnel. The reason for this phenomenon is unknown and needs further investigation. (author)

  5. Aerodynamic Simulation of Indoor Flight

    Science.gov (United States)

    De Leon, Nelson; De Leon, Matthew N.

    2007-01-01

    We develop a two-dimensional flight simulator for lightweight (less than 10 g) indoor planes. The simulator consists of four coupled time differential equations describing the plane CG, plane pitch and motor. The equations are integrated numerically with appropriate parameters and initial conditions for two planes: (1) Science Olympiad and (2)…

  6. In-Flight Sleep of Flight Crew During a 7-hour Rest Break: Implications for Research and Flight Safety

    Science.gov (United States)

    Signal, T. Leigh; Gander, Philippa H.; van den Berg, Margo J.; Graeber, R. Curtis

    2013-01-01

    Study Objectives: To assess the amount and quality of sleep that flight crew are able to obtain during flight, and identify factors that influence the sleep obtained. Design: Flight crew operating flights between Everett, WA, USA and Asia had their sleep recorded polysomnographically for 1 night in a layover hotel and during a 7-h in-flight rest opportunity on flights averaging 15.7 h. Setting: Layover hotel and in-flight crew rest facilities onboard the Boeing 777-200ER aircraft. Participants: Twenty-one male flight crew (11 Captains, mean age 48 yr and 10 First Officers, mean age 35 yr). Interventions: N/A. Measurements and Results: Sleep was recorded using actigraphy during the entire tour of duty, and polysomnographically in a layover hotel and during the flight. Mixed model analysis of covariance was used to determine the factors affecting in-flight sleep. In-flight sleep was less efficient (70% vs. 88%), with more nonrapid eye movement Stage 1/Stage 2 and more frequent awakenings per h (7.7/h vs. 4.6/h) than sleep in the layover hotel. In-flight sleep included very little slow wave sleep (median 0.5%). Less time was spent trying to sleep and less sleep was obtained when sleep opportunities occurred during the first half of the flight. Multivariate analyses suggest age is the most consistent factor affecting in-flight sleep duration and quality. Conclusions: This study confirms that even during long sleep opportunities, in-flight sleep is of poorer quality than sleep on the ground. With longer flight times, the quality and recuperative value of in-flight sleep is increasingly important for flight safety. Because the age limit for flight crew is being challenged, the consequences of age adversely affecting sleep quantity and quality need to be evaluated. Citation: Signal TL; Gander PH; van den Berg MJ; Graeber RC. In-flight sleep of flight crew during a 7-hour rest break: implications for research and flight safety. SLEEP 2013;36(1):109–115. PMID:23288977

  7. The 'Sentinel Node' Concept: More Questions Raised than Answers Provided?

    Science.gov (United States)

    Schlag

    1998-01-01

    The prognosis of malignant disease is essentially determined by the metastatic potential of the primary tumor. In the past, scientific attention was chiefly directed to systemic metastasis. A multitude of biological and molecular tumor markers and mechanisms has been uncovered enabling a better contemporary understanding of the process of hematogenic metastasis. This is in contrast with our knowledge of the mechanisms and pathways of lymphatic tumor spread, which is rather limited. We do know, however, that adequate surgical clearance of the regional lymphatics improves treatment results of many tumors. How far this lymph node dissection is directly therapeutic is a source of controversy. While in some instances, a stage-adjusted survival benefit was demonstrated, this may very well be attributable at least in part to the phenomenon of stage migration (Will Rodgers phenomenon) through better staging. However, it is uncontested that an established diagnosis of regional lymphatic spread is prognostically significant and should influence the indication for additional therapy and eventually for an intensive follow-up. For many tumors, the indication for adjuvant chemotherapy depends on the nodal status. On the other hand, it is equally well known that aggressive lymphatic dissection increases perioperative morbidity and even mortality. Long-term sequellae from regional lymphatic dissection are common and the effect on the local, maybe even the systemic immunological response to the malignant disease, remains unclear. To incur such risk seems especially problematic in those patients without any lymphatic spread at the time of the pathologist's work-up. Thus, there is ongoing debate about the rationale, value, extent, advantage, or disadvantage of regional surgical lymph node dissection or even radiotherapy of the regional lymphatic drainage area for many different tumors. A considerable step forward could be made if there was any diagnostic modality enabling a reliable

  8. The sentinel lymph node spread determines quantitatively melanoma seeding to non-sentinel lymph nodes and survival.

    Science.gov (United States)

    Ulmer, Anja; Dietz, Klaus; Werner-Klein, Melanie; Häfner, Hans-Martin; Schulz, Claudia; Renner, Philipp; Weber, Florian; Breuninger, Helmut; Röcken, Martin; Garbe, Claus; Fierlbeck, Gerhard; Klein, Christoph A

    2018-03-01

    Complete lymph node dissection (CLND) after a positive sentinel node (SN) biopsy provides important prognostic information in melanoma patients but has been questioned for therapeutic use recently. We explored whether quantification of the tumour spread to SNs may replace histopathology of non-sentinel nodes (NSNs) for staging purposes. We quantified melanoma spread in SNs and NSNs in 128 patients undergoing CLND for a positive SN. In addition to routine histopathology, one-half of each of all 1496 SNs and NSNs was disaggregated into a single cell suspension and stained immunocytochemically to determine the number of melanoma cells per 10 6 lymph node cells, i.e. the disseminated cancer cell density (DCCD). We uncovered melanoma spread to NSNs in the majority of patients; however, the tumour load and the proportion of positive nodes were significantly lower in NSNs than in SNs. The relation between SN and NSN spread could be described by a mathematical function with DCCD NSN  = DCCD SN c /10 1 - c (c = 0.69; 95% confidence interval [CI]: 0.62-0.76). At a median follow-up of 67 months, multivariable Cox regression analyses revealed that DCCD SN (p = 0.02; HR 1.34, 95% CI: 1.05-1.71) and the total number of pathologically positive nodes (p = 0.02; HR 1.53, 95% CI: 1.07-2.22) were significant risk factors after controlling for age, gender, thickness of melanoma and ulceration status. A prognostic model based on DCCD SN and melanoma thickness predicted outcome as accurately as a model including pathological information of both SNs and NSNs. The assessment of DCCD SN renders CLND for staging purposes unnecessary. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Altitude exposures during commercial flight: a reappraisal.

    Science.gov (United States)

    Hampson, Neil B; Kregenow, David A; Mahoney, Anne M; Kirtland, Steven H; Horan, Kathleen L; Holm, James R; Gerbino, Anthony J

    2013-01-01

    Hypobaric hypoxia during commercial air travel has the potential to cause or worsen hypoxemia in individuals with pre-existing cardiopulmonary compromise. Knowledge of cabin altitude pressures aboard contemporary flights is essential to counseling patients accurately about flying safety. The objective of the study was to measure peak cabin altitudes during U.S. domestic commercial flights on a variety of aircraft. A handheld mountaineering altimeter was carried by the investigators in the plane cabin during commercial air travel and peak cabin altitude measured. The values were then compared between aircraft models, aircraft classes, and distances flown. The average peak cabin altitude on 207 flights aboard 17 different aircraft was 6341 +/- 1813 ft (1933 m +/- 553 m), significantly higher than when measured in a similar fashion in 1988. Peak cabin altitude was significantly higher for flights longer than 750 mi (7085 +/- 801 ft) compared to shorter flights (5160 +/- 2290 ft/1573 +/- 698 m). Cabin altitude increased linearly with flight distance for flights up to 750 mi in length, but was independent of flight distance for flights exceeding 750 mi. Peak cabin altitude was less than 5000 ft (1524 m) in 70% of flights shorter than 500 mi. Peak cabin altitudes greater than 8000 ft (2438 m) were measured on approximately 10% of the total flights. Peak cabin altitude on commercial aircraft flights has risen over time. Cabin altitude is lower with flights of shorter distance. Physicians should take these factors into account when determining an individual's need for supplemental oxygen during commercial air travel.

  10. Online Learning Flight Control for Intelligent Flight Control Systems (IFCS)

    Science.gov (United States)

    Niewoehner, Kevin R.; Carter, John (Technical Monitor)

    2001-01-01

    The research accomplishments for the cooperative agreement 'Online Learning Flight Control for Intelligent Flight Control Systems (IFCS)' include the following: (1) previous IFC program data collection and analysis; (2) IFC program support site (configured IFC systems support network, configured Tornado/VxWorks OS development system, made Configuration and Documentation Management Systems Internet accessible); (3) Airborne Research Test Systems (ARTS) II Hardware (developed hardware requirements specification, developing environmental testing requirements, hardware design, and hardware design development); (4) ARTS II software development laboratory unit (procurement of lab style hardware, configured lab style hardware, and designed interface module equivalent to ARTS II faceplate); (5) program support documentation (developed software development plan, configuration management plan, and software verification and validation plan); (6) LWR algorithm analysis (performed timing and profiling on algorithm); (7) pre-trained neural network analysis; (8) Dynamic Cell Structures (DCS) Neural Network Analysis (performing timing and profiling on algorithm); and (9) conducted technical interchange and quarterly meetings to define IFC research goals.

  11. Meshfree Local Radial Basis Function Collocation Method with Image Nodes

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Seung Ki; Kim, Minjae [Pukyong National University, Busan (Korea, Republic of)

    2017-07-15

    We numerically solve two-dimensional heat diffusion problems by using a simple variant of the meshfree local radial-basis function (RBF) collocation method. The main idea is to include an additional set of sample nodes outside the problem domain, similarly to the method of images in electrostatics, to perform collocation on the domain boundaries. We can thereby take into account the temperature profile as well as its gradients specified by boundary conditions at the same time, which holds true even for a node where two or more boundaries meet with different boundary conditions. We argue that the image method is computationally efficient when combined with the local RBF collocation method, whereas the addition of image nodes becomes very costly in case of the global collocation. We apply our modified method to a benchmark test of a boundary value problem, and find that this simple modification reduces the maximum error from the analytic solution significantly. The reduction is small for an initial value problem with simpler boundary conditions. We observe increased numerical instability, which has to be compensated for by a sufficient number of sample nodes and/or more careful parameter choices for time integration.

  12. 3D inkjet printed disposable environmental monitoring wireless sensor node

    KAUST Repository

    Farooqui, Muhammad Fahad

    2017-10-24

    We propose a disposable, miniaturized, moveable, fully integrated 3D inkjet-printed wireless sensor node for large area environmental monitoring applications. As a proof of concept, we show the wireless sensing of temperature, humidity and H2S levels which are important for early warnings of two critical environmental conditions namely forest fires and industrial gas leaks. The temperature sensor has TCR of -0.018/°, the highest of any inkjet-printed sensor and the H2S sensor can detect as low as 3 ppm of gas. These sensors and an antenna have been realized on the walls of a 3D-printed cubic package which encloses the microelectronics developed on a 3D-printed circuit board. Hence, 3D printing and inkjet printing have been combined in order to realize a unique low-cost, fully integrated wireless sensor node. Field tests show that these sensor nodes can wirelessly communicate up to a distance of over 100m. Our proposed sensor node can be a part of internet of things with the aim of providing a better and safe living.

  13. Staging of Cervical Lymph Nodes in Oral Squamous Cell Carcinoma

    DEFF Research Database (Denmark)

    Norling, Rikke; Buron, Birgitte Marie Due; Therkildsen, Marianne Hamilton

    2014-01-01

    INTRODUCTION: Clinical staging of patients with oral squamous cell carcinoma (OSCC) is crucial for the choice of treatment. Computed tomography (CT) and/or magnetic resonance imaging (MRI) are typically recommended and used for staging of the cervical lymph nodes (LNs). Although ultrasonography (US...

  14. Biochemical aspects of single-node cuttings of Ricinodendron ...

    African Journals Online (AJOL)

    NEHEMIE

    2013-03-06

    Mar 6, 2013 ... changes, basal single-node leafy cuttings were treated with different .... with local material and providing an internal irradiance of 20 to 32%. ..... higher in rooting cutting during the initiation phase). Phenolics ... Chrysanthemum cuttings as affected by nitrogen supply and cold- storage. Ann. Bot. 85:697-701.

  15. Sentinel node biopsy for melanoma: a study of 241 patients

    DEFF Research Database (Denmark)

    Chakera, Annette Hougaard; Drzewiecki, Krzysztof Tadeusz; Jakobsen, Annika Loft

    2004-01-01

    The aim of this study was to evaluate the sentinel node biopsy (SNB) technique for melanoma using both radiocolloid and blue dye in 241 clinically N0 patients with melanomas >1.0 mm, or thinner lesions exhibiting regression/ulceration. We showed that an increase in injected radioactivity increased...

  16. NIM: A Node Influence Based Method for Cancer Classification

    Directory of Open Access Journals (Sweden)

    Yiwen Wang

    2014-01-01

    Full Text Available The classification of different cancer types owns great significance in the medical field. However, the great majority of existing cancer classification methods are clinical-based and have relatively weak diagnostic ability. With the rapid development of gene expression technology, it is able to classify different kinds of cancers using DNA microarray. Our main idea is to confront the problem of cancer classification using gene expression data from a graph-based view. Based on a new node influence model we proposed, this paper presents a novel high accuracy method for cancer classification, which is composed of four parts: the first is to calculate the similarity matrix of all samples, the second is to compute the node influence of training samples, the third is to obtain the similarity between every test sample and each class using weighted sum of node influence and similarity matrix, and the last is to classify each test sample based on its similarity between every class. The data sets used in our experiments are breast cancer, central nervous system, colon tumor, prostate cancer, acute lymphoblastic leukemia, and lung cancer. experimental results showed that our node influence based method (NIM is more efficient and robust than the support vector machine, K-nearest neighbor, C4.5, naive Bayes, and CART.

  17. Node Heterogeneity for Energy Efficient Synchronization for Wireless Sensor Network

    DEFF Research Database (Denmark)

    Dnyaneshwar, Mantri; Prasad, Neeli R.; Prasad, Ramjee

    2016-01-01

    The energy of the node in the Wireless Sensor Networks (WSNs) is scare and causes the variation in the lifetime of the network. Also, the throughput and delay of the network depend on how long the network sustains i.e. energy consumption. One way to increase the sustainability of network...

  18. A wireless laser displacement sensor node for structural health monitoring.

    Science.gov (United States)

    Park, Hyo Seon; Kim, Jong Moon; Choi, Se Woon; Kim, Yousok

    2013-09-30

    This study describes a wireless laser displacement sensor node that measures displacement as a representative damage index for structural health monitoring (SHM). The proposed measurement system consists of a laser displacement sensor (LDS) and a customized wireless sensor node. Wireless communication is enabled by a sensor node that consists of a sensor module, a code division multiple access (CDMA) communication module, a processor, and a power module. An LDS with a long measurement distance is chosen to increase field applicability. For a wireless sensor node driven by a battery, we use a power control module with a low-power processor, which facilitates switching between the sleep and active modes, thus maximizing the power consumption efficiency during non-measurement and non-transfer periods. The CDMA mode is also used to overcome the limitation of communication distance, which is a challenge for wireless sensor networks and wireless communication. To evaluate the reliability and field applicability of the proposed wireless displacement measurement system, the system is tested onsite to obtain the required vertical displacement measurements during the construction of mega-trusses and an edge truss, which are the primary structural members in a large-scale irregular building currently under construction. The measurement values confirm the validity of the proposed wireless displacement measurement system and its potential for use in safety evaluations of structural elements.

  19. Web development with MongoDB and Node.js

    CERN Document Server

    Krol, Jason

    2014-01-01

    This book is designed for developers of any skill level that want to get up and running using Node.js and MongoDB to build full featured web applications. A basic understanding of JavaScript and HTML is the only requirement for this book.

  20. Sentinel lymph node surgery in prostate cancer using magnetic particles.

    Science.gov (United States)

    Winter, Alexander; Engels, Svenja; Wawroschek, Friedhelm

    2018-03-01

    Superparamagnetic iron oxide nanoparticles (SPIONs) are tested to identify sentinel lymph nodes (SLNs) to exploit the advantages of targeted pelvic SLN dissection (sPLND), while circumventing the disadvantages of established radioactive labeling. Here we review recent studies about sPLND in prostate cancer (PCa), including the first results of SLN detection using intraprostatic SPION-injection. A recent systematic literature review reveals that the diagnostic accuracy of sPLND is comparable with extended PLND (ePLND). sPLND combined with ePLND achieve better node removal by increasing the number of affected nodes. The first sentinel-based nomogram predicting lymph node invasion is established. A sentinel-nomogram update provides comparative predictions relative to ePLND models. sPLND using a magnetometer and SPIONs as a tracer is successful whenever applied to PCa, and SLN identification using MRI after intraprostatic injection of SPIONs is feasible. SLNs are present in an unexpectedly high number outside the ePLND template. SLN detection outside the ePLND template and the increased diagnostic value of sPLND compared with ePLND supports the individualized extension of PLND using sPLND in PCa. SPION-MRI, combined with a hand-held magnetometer, provides a nonradioactive technique for preoperative and intraoperative SLN localization. Further studies are required to evaluate the effects of sPLND on oncological outcomes.

  1. Search for an optimal colloid for sentinel node imaging

    International Nuclear Information System (INIS)

    Imam, S.K.; Killingsworth, M.

    2005-01-01

    This study aims at finding a cost-effective and stable colloid of appropriate size to replace antimony sulfide colloid which is now in routine use in Australia for sentinel lymph node (SLN) imaging. For this reason we evaluated three colloids; namely phytate, hepatate and stannous fluoride (SnF 2 ). As colloids of particle size of 100-200 nm seem to be appropriate for sentinel node imaging, the three radiolabelled colloid preparations were filtered through 0.1 and 0.22 μm filters and then studied on electron microscope. Electron microscopy showed that unlike phytate, the particle size of the hepatate and SnF 2 colloids did not increase beyond the size limit of 200 nm over a period of as long as 26 hours. Instead, they remained well within the size limits chosen. The stability of particle size is required for intra-operative gamma probe lymphatic mapping that sometimes may be performed on the following day. Hepatate and SnF 2 colloids appeared to be more suited for sentinel lymph node imaging, the latter being an inhouse product is more cost-effective. Further studies based on nodal uptake and the behavior of these two radiopharmaceuticals in animals is suggested in order to evaluate their potential for future wide-spread application in human sentinel node imaging. (author)

  2. Echo pattern of lymph nodes in colorectal cancer

    DEFF Research Database (Denmark)

    Rafaelsen, Søren Rafael; Kronborg, Ole; Fenger, Claus

    1992-01-01

    Surgical specimens from 75 patients with colorectal cancer were examined within 15 min of removal with a 7.5 MHz linear-array transducer. The echo pattern of 139 lymph nodes was analysed to evaluate previous criteria of malignancy and to establish other possible criteria, which could be tested...

  3. In-node cognitive power control in Wireless Sensor Networks

    NARCIS (Netherlands)

    Chincoli, Michele; Liotta, Antonio

    2017-01-01

    Reliability, interoperability and efficiency are fundamental in Wireless Sensor Network deployment. Herein we look at how transmission power control may be used to reduce interference, which is particularly problematic in high-density conditions. We adopt a distributed approach where every node has

  4. [Sentinel node in melanoma and breast cancer. Current considerations].

    Science.gov (United States)

    Vidal-Sicart, S; Vilalta Solsona, A; Alonso Vargas, M I

    2015-01-01

    The main objectives of sentinel node (SN) biopsy is to avoid unnecessary lymphadenectomies and to identify the 20-25% of patients with occult regional metastatic involvement. This technique reduces the associated morbidity from lymphadenectomy and increases the occult lymphatic metastases identification rate by offering the pathologist the or those lymph nodes with the highest probability of containing metastatic cells. Pre-surgical lymphoscintigraphy is considered a "road map" to guide the surgeon towards the sentinel nodes and to localize unpredictable lymphatic drainage patterns. The SPECT/CT advantages include a better SN detection rate than planar images, the ability to detect SNs in difficult to interpret studies, better SN depiction, especially in sites closer to the injection site and better anatomic localization. These advantages may result in a change in the patient's clinical management both in melanoma and breast cancer. The correct SN evaluation by pathology implies a tumoral load stratification and further prognostic implication. The use of intraoperative imaging devices allows the surgeon a better surgical approach and precise SN localization. Several studies reports the added value of such devices for more sentinel nodes excision and a complete monitoring of the whole procedure. New techniques, by using fluorescent or hybrid tracers, are currently being developed. Copyright © 2014 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  5. Power Aware Simulation Framework for Wireless Sensor Networks and Nodes

    Directory of Open Access Journals (Sweden)

    Daniel Weber

    2008-07-01

    Full Text Available The constrained resources of sensor nodes limit analytical techniques and cost-time factors limit test beds to study wireless sensor networks (WSNs. Consequently, simulation becomes an essential tool to evaluate such systems.We present the power aware wireless sensors (PAWiS simulation framework that supports design and simulation of wireless sensor networks and nodes. The framework emphasizes power consumption capturing and hence the identification of inefficiencies in various hardware and software modules of the systems. These modules include all layers of the communication system, the targeted class of application itself, the power supply and energy management, the central processing unit (CPU, and the sensor-actuator interface. The modular design makes it possible to simulate heterogeneous systems. PAWiS is an OMNeT++ based discrete event simulator written in C++. It captures the node internals (modules as well as the node surroundings (network, environment and provides specific features critical to WSNs like capturing power consumption at various levels of granularity, support for mobility, and environmental dynamics as well as the simulation of timing effects. A module library with standardized interfaces and a power analysis tool have been developed to support the design and analysis of simulation models. The performance of the PAWiS simulator is comparable with other simulation environments.

  6. A Wind Energy Powered Wireless Temperature Sensor Node

    Directory of Open Access Journals (Sweden)

    Chuang Zhang

    2015-02-01

    Full Text Available A wireless temperature sensor node composed of a piezoelectric wind energy harvester, a temperature sensor, a microcontroller, a power management circuit and a wireless transmitting module was developed. The wind-induced vibration energy harvester with a cuboid chamber of 62 mm × 19.6 mm × 10 mm converts ambient wind energy into electrical energy to power the sensor node. A TMP102 temperature sensor and the MSP430 microcontroller are used to measure the temperature. The power management module consists of LTC3588-1 and LT3009 units. The measured temperature is transmitted by the nRF24l01 transceiver. Experimental results show that the critical wind speed of the harvester was about 5.4 m/s and the output power of the harvester was about 1.59 mW for the electrical load of 20 kΩ at wind speed of 11.2 m/s, which was sufficient to power the wireless sensor node to measure and transmit the temperature every 13 s. When the wind speed increased from 6 m/s to 11.5 m/s, the self-powered wireless sensor node worked normally.

  7. Compact Public-Key Implementations for RFID and Sensor Nodes

    Science.gov (United States)

    Batina, Lejla; Sakiyama, Kazuo; Verbauwhede, Ingrid M. R.

    Embedded systems have become extremely important and new applications are taking a larger portion of the market every day. Radio frequency identification (RFID) tags and sensor nodes are recent and challenging examples and they imply very low budgets for the number of gates, power, bandwidth, etc. while they often require security solutions.

  8. Sentinel Lymph Node Dissection in Locally Recurrent Breast Cancer

    DEFF Research Database (Denmark)

    Uth, Charlotte Caspara; Christensen, Mette Haulund; Oldenbourg, Mette Holmqvist

    2015-01-01

    BACKGROUND: The aim of this study was to investigate the use of sentinel lymph node dissection (SLND) in the treatment of patients with locally recurrent breast cancer. METHODS: A total of 147 patients with locally recurrent breast cancer were included from five different breast surgery departments...

  9. Regression Nodes: Extending attack trees with data from social sciences

    NARCIS (Netherlands)

    Bullee, Jan-Willem; Montoya, L.; Pieters, Wolter; Junger, Marianne; Hartel, Pieter H.

    In the field of security, attack trees are often used to assess security vulnerabilities probabilistically in relation to multi-step attacks. The nodes are usually connected via AND-gates, where all children must be executed, or via OR-gates, where only one action is necessary for the attack step to

  10. Thick melanoma: prognostic value of positive sentinel nodes

    NARCIS (Netherlands)

    Vermeeren, Lenka; van der Ent, Fred W. C.; Sastrowijoto, Prapto S. H.; Hulsewé, Karel W. E.

    2009-01-01

    BACKGROUND: Sentinel lymph node biopsy (SNB) is a widely accepted procedure used to accurately stage patients with melanoma. Its value in patients with thick melanoma (Breslow thickness >4 mm) is reason for discussion because of the generally poor prognosis of these patients. The purpose of this

  11. Link Prediction in Evolving Networks Based on Popularity of Nodes.

    Science.gov (United States)

    Wang, Tong; He, Xing-Sheng; Zhou, Ming-Yang; Fu, Zhong-Qian

    2017-08-02

    Link prediction aims to uncover the underlying relationship behind networks, which could be utilized to predict missing edges or identify the spurious edges. The key issue of link prediction is to estimate the likelihood of potential links in networks. Most classical static-structure based methods ignore the temporal aspects of networks, limited by the time-varying features, such approaches perform poorly in evolving networks. In this paper, we propose a hypothesis that the ability of each node to attract links depends not only on its structural importance, but also on its current popularity (activeness), since active nodes have much more probability to attract future links. Then a novel approach named popularity based structural perturbation method (PBSPM) and its fast algorithm are proposed to characterize the likelihood of an edge from both existing connectivity structure and current popularity of its two endpoints. Experiments on six evolving networks show that the proposed methods outperform state-of-the-art methods in accuracy and robustness. Besides, visual results and statistical analysis reveal that the proposed methods are inclined to predict future edges between active nodes, rather than edges between inactive nodes.

  12. Autonomous solutions for powering wireless sensor nodes in rivers

    Science.gov (United States)

    Kamenar, E.; Maćešić, S.; Gregov, G.; Blažević, D.; Zelenika, S.; Marković, K.; Glažar, V.

    2015-05-01

    There is an evident need for monitoring pollutants and/or other conditions in river flows via wireless sensor networks. In a typical wireless sensor network topography, a series of sensor nodes is to be deployed in the environment, all wirelessly connected to each other and/or their gateways. Each sensor node is composed of active electronic devices that have to be constantly powered. In general, batteries can be used for this purpose, but problems may occur when they have to be replaced. In the case of large networks, when sensor nodes can be placed in hardly accessible locations, energy harvesting can thus be a viable powering solution. The possibility to use three different small-scale river flow energy harvesting principles is hence thoroughly studied in this work: a miniaturized underwater turbine, a so-called `piezoelectric eel' and a hybrid turbine solution coupled with a rigid piezoelectric beam. The first two concepts are then validated experimentally in laboratory as well as in real river conditions. The concept of the miniaturised hydro-generator is finally embedded into the actual wireless sensor node system and its functionality is confirmed.

  13. High field MRI of axillary lymph nodes and breast cancer

    NARCIS (Netherlands)

    Korteweg, M.A.

    2011-01-01

    In this thesis nodal characteristics have been assessed with high field Magnetic Resonance Imaging (MRI) using a clinical scanner in order to discriminate non-metastatic from metastatic nodes of breast cancer patients. The final goal is to non-invasively determine nodal and tumor stage of breast

  14. Metastatic Carcinoma Of The BreastWith Inguinal Lymph Node ...

    African Journals Online (AJOL)

    To report two cases of advanced breast carcinoma with metastases to the inguinal lymph nodes in two Nigerian women. The University of Port Harcourt Teaching Hospital, Port Harcourt, Nigeria. Two Nigerian women, one aged 40 years with an invasive lobular carcinoma of the right breast, and the other aged 48 yearswith ...

  15. Retroperitoneal unicentric Castleman's disease (giant lymph node hyperplasia: case report

    Directory of Open Access Journals (Sweden)

    Jaques Waisberg

    Full Text Available CONTEXT AND OBJECTIVE: Castleman's disease, or giant lymph node hyperplasia, is a rare disorder of the lymphoid tissue that causes lymph node enlargement. It is considered benign in its localized form, but aggressive in the multicentric type. The definitive diagnosis is based on postoperative pathological findings. The aim here was to describe a case of retroperitoneal unicentric Castleman's disease in the retroperitoneum. CASE REPORT: A 61-year old white male with weight loss and listlessness presented with moderate arterial hypertension and leukopenia. Abdominal tomography revealed a 5 x 4 x 5 cm oval mass of low attenuation, with inner calcification and intense enhancement on intravenous contrast, located in the retroperitoneal region, between the left kidney and the aorta, at the renal hilus. Exploratory laparotomy revealed a non-pulsatile solid oval mass situated in the retroperitoneum, adjacent to the left renal hilus. The retroperitoneal lesion was removed in its entirety. Examination of frozen samples revealed benign lymph node tissue and histopathological examination of the surgical sample revealed hyaline-vascular giant lymph node hyperplasia (Castleman's disease. The patient was discharged on the 12th day without significant events. Two months after the operation, the patient was readmitted with severe cardiac insufficiency, acute renal failure and bronchopneumonia, which progressed to acute respiratory insufficiency, sepsis and death.

  16. Peritumoural vs intratumoural injections in sentinel node lymphoscintigraphy

    International Nuclear Information System (INIS)

    MacFarlane, L.; Cardaci, G.

    2002-01-01

    Full text: Lymphoscintigraphy has emerged as a method of detecting sentinel lymph nodes (SLN) in breast cancer. Our department started performing these studies in 2001, using 99mTc-Colloidal Antimony Sulphide Injection -dose 30-50MBq. Two methods of injection were used: (a) peritumoural plus subdermal injection - 1.25ml volume (PT), or (b) direct intratumoural injection - 0.2ml volume (IT), both followed by 5-10 min of gentle massage. Patients with a non-palpable mass required a hookwire (HW) inserted at time of injection, and a hotpack was applied in lieu of massage. 125 patients were retrospectively assessed, with 45 PT, 37 IT, 38 HW, and 5 patients had cavity injections. For PT injections, 93% had axillary node drainage (AN), 27% had internal mammary node drainage (IM) and 4% had no drainage to nodes, despite delayed imaging. For IT injections, 84% had AN, 24% had IM, 11% showed no drainage. Of patients having HW, 66% had AN, 34% had IM, 26% no drainage. In our experience, PT injection has a higher yield for SLN localisation than direct IT injection. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  17. Evaluation of mesenteric lymph nodes in children with abdominal pain

    International Nuclear Information System (INIS)

    Jedrzejewski, G.

    2008-01-01

    The aim of this study was to evaluate the prevalence of enlarged mesenteric lymph nodes seen on pediatric abdominal ultrasound examinations performed in children with abdominal pain. Ultrasound was performed with Sonoline Elegra and Philips iU-22 units with convex-array 2-5 MHz transducer for the general abdominal examination, and in addition with convex 5-8 MHz or linear 7.5 MHz transducers specially to detect lymph nodes. Enlarged lymph nodes were found in 248 (21,2%) out of 1171 symptomatic patients. In 53 patients some other abnormalities were found. The nodes were mostly disc-like and oval in shape. They had usually a homogeneous appearance and were iso- or hypoechoic relative to the surrounding tissues and intestinal loops. Mesenteric lymphadenitis is commonly reported in children with acute, chronic or recurrent abdominal pain and no evidence of other pathologies, and has been reported as one of the most common explanation for acute right lower quadrant abdominal pain. (authors)

  18. Optical biopsy of lymph node morphology using optical coherence tomography.

    Science.gov (United States)

    Luo, Wei; Nguyen, Freddy T; Zysk, Adam M; Ralston, Tyler S; Brockenbrough, John; Marks, Daniel L; Oldenburg, Amy L; Boppart, Stephen A

    2005-10-01

    Optical diagnostic imaging techniques are increasingly being used in the clinical environment, allowing for improved screening and diagnosis while minimizing the number of invasive procedures. Diffuse optical tomography, for example, is capable of whole-breast imaging and is being developed as an alternative to traditional X-ray mammography. While this may eventually be a very effective screening method, other optical techniques are better suited for imaging on the cellular and molecular scale. Optical Coherence Tomography (OCT), for instance, is capable of high-resolution cross-sectional imaging of tissue morphology. In a manner analogous to ultrasound imaging except using optics, pulses of near-infrared light are sent into the tissue while coherence-gated reflections are measured interferometrically to form a cross-sectional image of tissue. In this paper we apply OCT techniques for the high-resolution three-dimensional visualization of lymph node morphology. We present the first reported OCT images showing detailed morphological structure and corresponding histological features of lymph nodes from a carcinogen-induced rat mammary tumor model, as well as from a human lymph node containing late stage metastatic disease. The results illustrate the potential for OCT to visualize detailed lymph node structures on the scale of micrometastases and the potential for the detection of metastatic nodal disease intraoperatively.

  19. Breast and Axillary Lymph Nodes Metastasis five years after Radical ...

    African Journals Online (AJOL)

    Breast is an uncommon and rare site for metastasis. Primary and secondary tumors of the breast need to be differentiated as management is different. We present a 67 year old female patient with two breast lumps and an axillary lymph node, 5 years after nephrectomy for Renal Cell Carcinoma (RCC). Mammogram report ...

  20. Impact of constrained rewiring on network structure and node dynamics

    Science.gov (United States)

    Rattana, P.; Berthouze, L.; Kiss, I. Z.

    2014-11-01

    In this paper, we study an adaptive spatial network. We consider a susceptible-infected-susceptible (SIS) epidemic on the network, with a link or contact rewiring process constrained by spatial proximity. In particular, we assume that susceptible nodes break links with infected nodes independently of distance and reconnect at random to susceptible nodes available within a given radius. By systematically manipulating this radius we investigate the impact of rewiring on the structure of the network and characteristics of the epidemic. We adopt a step-by-step approach whereby we first study the impact of rewiring on the network structure in the absence of an epidemic, then with nodes assigned a disease status but without disease dynamics, and finally running network and epidemic dynamics simultaneously. In the case of no labeling and no epidemic dynamics, we provide both analytic and semianalytic formulas for the value of clustering achieved in the network. Our results also show that the rewiring radius and the network's initial structure have a pronounced effect on the endemic equilibrium, with increasingly large rewiring radiuses yielding smaller disease prevalence.

  1. Node counting in wireless ad-hoc networks

    NARCIS (Netherlands)

    Evers, J.H.M.; Kiss, D.; Kowalczyk, W.; Navilarekallu, T.; Renger, D.R.M.; Sella, L.; Timperio, V.; Viorel, A.; Wijk, van A.C.C.; Yzelman, A.J.; Planqué, B.; Bhulai, S.; Hulshof, J.; Kager, W.; Rot, T.

    2012-01-01

    We study wireless ad-hoc networks consisting of small microprocessors with limited memory, where the wireless communication between the processors can be highly unreliable. For this setting, we propose a number of algorithms to estimate the number of nodes in the network, and the number of direct

  2. Quality metric for accurate overlay control in <20nm nodes

    Science.gov (United States)

    Klein, Dana; Amit, Eran; Cohen, Guy; Amir, Nuriel; Har-Zvi, Michael; Huang, Chin-Chou Kevin; Karur-Shanmugam, Ramkumar; Pierson, Bill; Kato, Cindy; Kurita, Hiroyuki

    2013-04-01

    The semiconductor industry is moving toward 20nm nodes and below. As the Overlay (OVL) budget is getting tighter at these advanced nodes, the importance in the accuracy in each nanometer of OVL error is critical. When process owners select OVL targets and methods for their process, they must do it wisely; otherwise the reported OVL could be inaccurate, resulting in yield loss. The same problem can occur when the target sampling map is chosen incorrectly, consisting of asymmetric targets that will cause biased correctable terms and a corrupted wafer. Total measurement uncertainty (TMU) is the main parameter that process owners use when choosing an OVL target per layer. Going towards the 20nm nodes and below, TMU will not be enough for accurate OVL control. KLA-Tencor has introduced a quality score named `Qmerit' for its imaging based OVL (IBO) targets, which is obtained on the-fly for each OVL measurement point in X & Y. This Qmerit score will enable the process owners to select compatible targets which provide accurate OVL values for their process and thereby improve their yield. Together with K-T Analyzer's ability to detect the symmetric targets across the wafer and within the field, the Archer tools will continue to provide an independent, reliable measurement of OVL error into the next advanced nodes, enabling fabs to manufacture devices that meet their tight OVL error budgets.

  3. [Flow cytometry in datecting lymph node micrometastasis in colorectal cancer].

    Science.gov (United States)

    Sun, Q; Ding, Y; Zhang, J

    2001-01-25

    To study the methodology and significance of flow cytometry in detecting lymph node micrometastasis of colorectal cancer. One hundred sixty-two cellular suspensions were prepared with lymph nodes which were resected radically on 25 patients with colorectal cancer and in which no cancer cells were found by HE staining. Different concentrations of cultured Lovo colorectal cancer cells were added into the celular suspension prepared from lymph node tissue of persons without colorectal cancer in order to prepare a control model. Dual staining with CK/FTTC and PI was made to the sedimetns from those 2 kinds of suspension. Flow cytometry was used to detect cancer cells. An ideal correlation was obtained between the detection value and the theoretical value of cancer cells in the specimen suspensions and control models (r = 0.097 6) with a sensitivity rate of 10/10(5). Cancer cells were detected from 7 out of the 25 patients and 30 of the 162 cellular suspensions. The detection rate was correlated with the size and infiltrating depth of the cancer. Flow cytometry is a reliable, rapid, and quantitative method for detecting lymph node micrometastasis in colorectal cancer.

  4. Uptake kinetics of relatively insoluble particles by tracheobronchial lymph nodes

    International Nuclear Information System (INIS)

    Thomas, R.G.

    1976-01-01

    Tracheobronchial lymph nodes accumulate a portion of material deposited in the deep lung following inhalation of relatively insoluble particles. Experiments involving a variety of compounds, inhaled singly or repeatedly, indicate that the kinetics of lymph node uptake are fairly independent of particle characteristics and mammalian species. The buildup per unit weight of nodal tissue compared with that of lung tissue, with time, can be represented by a linear logarithmic function. However, since the scatter in experimental points may be large at any given time after inhalation exposure, a number of different kinetic descriptions of uptake can be derived. The logarithmic pattern of accumulation can be approximated over an extended time range (several years) by use of a combination of first-order kinetics of loss from the lung and of buildup in lymph nodes, but it is recognized that the processes are much more complicated than this treatment would indicate. Clearance (loss) from the lymph nodes is not well defined, but this aspect is discussed in light of the kinetic models presented

  5. Lymph nodes tuberculosis: A retrospective study on clinical and ...

    African Journals Online (AJOL)

    Lymph nodes tuberculosis represents 30 percent of extra pulmonary tuberculosis in Morocco. We report here the experience of the pulmonology unit of the Avicenne Military Hospital in Marrakech for a period of 4 years. Our study interested 30 patients (15 males and 15 females) with an average age of 29 years old (10 to 62 ...

  6. Age Related Variations in The Architecture of Caprine Haemal Nodes

    African Journals Online (AJOL)

    Age related variations in the architecture of caprine haemal nodes were studied in West African dwarf goats aged between 1-24 months. Variations were observed in the thickness of the capsule, the content and organization of the cortical and medullary parenchyma as well as the stroma. In young goats age between 1-4 ...

  7. A Wireless Laser Displacement Sensor Node for Structural Health Monitoring

    Directory of Open Access Journals (Sweden)

    Se Woon Choi

    2013-09-01

    Full Text Available This study describes a wireless laser displacement sensor node that measures displacement as a representative damage index for structural health monitoring (SHM. The proposed measurement system consists of a laser displacement sensor (LDS and a customized wireless sensor node. Wireless communication is enabled by a sensor node that consists of a sensor module, a code division multiple access (CDMA communication module, a processor, and a power module. An LDS with a long measurement distance is chosen to increase field applicability. For a wireless sensor node driven by a battery, we use a power control module with a low-power processor, which facilitates switching between the sleep and active modes, thus maximizing the power consumption efficiency during non-measurement and non-transfer periods. The CDMA mode is also used to overcome the limitation of communication distance, which is a challenge for wireless sensor networks and wireless communication. To evaluate the reliability and field applicability of the proposed wireless displacement measurement system, the system is tested onsite to obtain the required vertical displacement measurements during the construction of mega-trusses and an edge truss, which are the primary structural members in a large-scale irregular building currently under construction. The measurement values confirm the validity of the proposed wireless displacement measurement system and its potential for use in safety evaluations of structural elements.

  8. Salmonella in peripheral lymph nodes of healthy cattle at slaughter

    Science.gov (United States)

    To more fully characterize the burden of Salmonella enterica in bovine peripheral lymph nodes (PLN), PLN (n=5,450) were collected from healthy cattle at slaughter in 12 commercial abattoirs that slaughtered feedlot-fattened (FF) cattle exclusively (n=7), cattle removed (or culled) from breeding herd...

  9. Flight to Safety from European Stock Markets

    DEFF Research Database (Denmark)

    Aslanidis, Nektarios; Christiansen, Charlotte

    -return trade-off is positive and during flight-to-safety episodes it is negative. The effects of flight-to-safety episodes on the risk-return trade-off are qualitatively similar for own country flight-to-safety episodes, for flight from own country stock market to the US bond market, and for US flight......This paper investigates flight-to-safety from stocks to bonds in seven European markets. We use quantile regressions to identify flight-to-safety episodes. The simple risk-return trade-off on the stock markets is negative which is caused by flight-to-safety episodes: During normal periods, the risk...

  10. Post-Flight Data Analysis Tool

    Science.gov (United States)

    George, Marina

    2018-01-01

    A software tool that facilitates the retrieval and analysis of post-flight data. This allows our team and other teams to effectively and efficiently analyze and evaluate post-flight data in order to certify commercial providers.

  11. Optimized Lift for Autonomous Formation Flight

    Data.gov (United States)

    National Aeronautics and Space Administration — Experimental in-flight evaluations have demonstrated that the concept of formation flight can reduce fuel consumption of trailing aircraft by 10 percent. Armstrong...

  12. GRIP FLIGHT TRACKS AND ANIMATIONS V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Flight Tracks and Animations dataset includes both KML files and animation files. The KML files use Google Earth to show the flight tracks on a map. The...

  13. F-15 IFCS Intelligent Flight Control System

    Science.gov (United States)

    Bosworth, John T.

    2008-01-01

    This viewgraph presentation gives a detailed description of the F-15 aircraft, flight tests, aircraft performance and overall advanced neural network based flight control technologies for aerospace systems designs.

  14. Flight Activity and Crew Tracking System -

    Data.gov (United States)

    Department of Transportation — The Flight Activity and Crew Tracking System (FACTS) is a Web-based application that provides an overall management and tracking tool of FAA Airmen performing Flight...

  15. Core Flight System Satellite Starter Kit

    Data.gov (United States)

    National Aeronautics and Space Administration — The Core Flight System Satellite Starter Kit (cFS Kit) will allow a small satellite or CubeSat developer to rapidly develop, deploy, test, and operate flight...

  16. Positive Exchange of Flight Controls Program

    Science.gov (United States)

    1995-03-10

    This advisory circular provides guidance for all pilots, especially student pilots, flight instructors, and pilot examiners, on the recommended procedure to use for the positive exchange of flight controls between pilots when operating an aircraft.

  17. LCP nanoparticle for tumor and lymph node metastasis imaging

    Science.gov (United States)

    Tseng, Yu-Cheng

    A lipid/calcium/phosphate (LCP) nanoparticle formulation (particle diameter ˜25 nm) has previously been developed to delivery siRNA with superior efficiency. In this work, 111In was formulated into LCP nanoparticles to form 111In-LCP for SPECT/CT imaging. With necessary modifications and improvements of the LCP core-washing and surface-coating methods, 111In-LCP grafted with polyethylene glycol exhibited reduced uptake by the mononuclear phagocytic system. SPECT/CT imaging supported performed biodistribution studies, showing clear tumor images with accumulation of 8% or higher injected dose per gram tissue (ID/g) in subcutaneous, human-H460, lung-cancer xenograft and mouse-4T1, breast cancer metastasis models. Both the liver and the spleen accumulated ˜20% ID/g. Accumulation in the tumor was limited by the enhanced permeation and retention effect and was independent of the presence of a targeting ligand. A surprisingly high accumulation in the lymph nodes (˜70% ID/g) was observed. In the 4T1 lymph node metastasis model, the capability of intravenously injected 111In-LCP to visualize the size-enlarged and tumor-loaded sentinel lymph node was demonstrated. By analyzing the SPECT/CT images taken at different time points, the PK profiles of 111In-LCP in the blood and major organs were determined. The results indicated that the decrement of 111In-LCP blood concentration was not due to excretion, but to tissue penetration, leading to lymphatic accumulation. Larger LCP (diameter ˜65 nm) nanoparticles were also prepared for the purpose of comparison. Results indicated that larger LCP achieved slightly lower accumulation in the tumor and lymph nodes, but much higher accumulation in the liver and spleen; thus, larger nanoparticles might not be favorable for imaging purposes. We also demonstrated that LCP with a diameter of ˜25 nm were better able to penetrate into tissues, travel in the lymphatic system and preferentially accumulate in the lymph nodes due to 1) small

  18. Programming Sustainable Urban Nodes for Spontaneous, Intensive Urban Environments

    Science.gov (United States)

    Szubryt-Obrycka, Adriana

    2017-10-01

    Urban development nowadays, not only in Poland but also throughout the world, is an important issue for planners, municipal authorities and residents themselves. New structures generated in spontaneous urban and suburban areas constitute randomly scattered seeds of excessive residential and little commercial functions which therein appear more often as temporary or even ephemeral installations emerging where it is temporarily needed. The more important special services are provided rarely. Correct thinking about creating cities involves simultaneous thinking on providing different basic functions required by local communities, but at the same time recognizing temporal fluctuations and distinction on what kind of amenities have to be provided in particular area permanently (such as e.g. medical care, preventive services and schools), with others retaining its mobile, non-formal character. An even greater problem is a restoration of urban structures in the areas affected by natural disasters or leftover areas being previously war zones, where similar deficits have significantly higher impact being potential cause of higher toll in human lives, if no functional nodes providing essential functions survived. The Ariadne’s Thread is a research project which proposes infrastructure and nodes for such urban areas. It develops new framework for creating nodes not only aimed at fulfilling basic needs of people but achieving social integration and build stability for fragile communities. The aim of the paper is to describe the process of identification of a relationship between needs of the inhabitants and both programmatic and ideological approach to Ariadne’s Thread (AT) node giving ultimately its architectural interpretation. The paper will introduce the process of recognition of local needs, the interpretive and/or participatory mechanisms of establishing the node as a response to this recognition containing conceptual programming, socio-cultural programming, and

  19. Free Flight Rotorcraft Flight Test Vehicle Technology Development

    Science.gov (United States)

    Hodges, W. Todd; Walker, Gregory W.

    1994-01-01

    A rotary wing, unmanned air vehicle (UAV) is being developed as a research tool at the NASA Langley Research Center by the U.S. Army and NASA. This development program is intended to provide the rotorcraft research community an intermediate step between rotorcraft wind tunnel testing and full scale manned flight testing. The technologies under development for this vehicle are: adaptive electronic flight control systems incorporating artificial intelligence (AI) techniques, small-light weight sophisticated sensors, advanced telepresence-telerobotics systems and rotary wing UAV operational procedures. This paper briefly describes the system's requirements and the techniques used to integrate the various technologies to meet these requirements. The paper also discusses the status of the development effort. In addition to the original aeromechanics research mission, the technology development effort has generated a great deal of interest in the UAV community for related spin-off applications, as briefly described at the end of the paper. In some cases the technologies under development in the free flight program are critical to the ability to perform some applications.

  20. The dynamics of parabolic flight: Flight characteristics and passenger percepts

    Science.gov (United States)

    Karmali, Faisal; Shelhamer, Mark

    2008-09-01

    Flying a parabolic trajectory in an aircraft is one of the few ways to create freefall on Earth, which is important for astronaut training and scientific research. Here we review the physics underlying parabolic flight, explain the resulting flight dynamics, and describe several counterintuitive findings, which we corroborate using experimental data. Typically, the aircraft flies parabolic arcs that produce approximately 25 s of freefall (0 g) followed by 40 s of enhanced force (1.8 g), repeated 30-60 times. Although passengers perceive gravity to be zero, in actuality acceleration, and not gravity, has changed, and thus we caution against the terms "microgravity" and "zero gravity." Despite the aircraft trajectory including large (45°) pitch-up and pitch-down attitudes, the occupants experience a net force perpendicular to the floor of the aircraft. This is because the aircraft generates appropriate lift and thrust to produce the desired vertical and longitudinal accelerations, respectively, although we measured moderate (0.2 g) aft-ward accelerations during certain parts of these trajectories. Aircraft pitch rotation (average 3°/s) is barely detectable by the vestibular system, but could influence some physics experiments. Investigators should consider such details in the planning, analysis, and interpretation of parabolic-flight experiments.

  1. Improved model for solar cosmic ray exposure in manned Earth orbital flights

    International Nuclear Information System (INIS)

    Wilson, J.W.; Nealy, J.E.; Atwell, W.; Cucinotta, F.A.; Shinn, J.L.; Townsend, L.W.

    1990-06-01

    A calculational model is derived for use in estimating Solar cosmic ray exposure to critical body organs in low-Earth orbit at the center of a large spherical shield of fixed thickness. The effects of the Earth's geomagnetic field and the astronauts' self-shielding are evaluated explicitly. The geomagnetic field model is an approximate tilted eccentric dipole with geomagnetic storms represented as a uniform-impressed field. The storm field is related to the planetary geomagnetic index K(sub p). The code is applied to the Shuttle geometry using the Shuttle mass distribution surrounding two locations on the flight deck. The Shuttle is treated as pure aluminum and the astronaut as soft tissue. Short-term, average fluence over a single orbit is calculated as a function of the location of the lines of nodes or long-term averages over all lines of nodes for a fixed inclination

  2. Identifying Nodes of Transmission in Disease Diffusion Through Social Media

    Science.gov (United States)

    Lamb, David Sebastian

    The spread of infectious diseases can be described in terms of three interrelated components: interaction, movement, and scale. Transmission between individuals requires some form of interaction, which is dependent on the pathogen, to occur. Diseases spread through the movement of their hosts; they spread across many spatial scales from local neighborhoods to countries, or temporal scales from days to years, or periodic intervals. Prior research into the spread of disease have examined diffusion processes retrospectively at regional or country levels, or developed differential equation or simulation models of the dynamics of disease transmission. While some of the more recent models incorporate all three components, they are limited in the way they understand where interactions occur. The focus has been on home or work, including contact with family or coworkers. The models reflect a lack of knowledge about how transmissions are made at specific locations in time, so-called nodes of transmission. That is, how individuals' intersections in time and space function in disease transmission. This project sought to use the three factors of interaction, movement, and scale to better understand the spread of disease in terms of the place of interaction called the node of transmission. The overarching objective of this research was: how can nodes of transmission be identified through individual activity spaces incorporating the three factors of infectious disease spread: interaction, movement, and scale?. This objective fed into three main sub-objectives: defining nodes of transmission, developing an appropriate methodology to identifying nodes of transmission, and applying it using geotagged social media data from Twitter. To develop an appropriate framework, this research relied on time geography, and traditional disease. This particularly relied on the idea of bundling to create the nodes, and a nesting effect that integrated scale. The data source used to identify nodes

  3. Internal mammary lymph node management – further direction

    Directory of Open Access Journals (Sweden)

    Vrana D

    2017-02-01

    Full Text Available D Vrana,1,2 J Gatek3,4 1Department of Oncology, 2Institute of Molecular and Translational Medicine, Faculty of Medicine and Dentistry, Palacky University, Olomouc, 3Department of Surgery, Atlas Hospital, 4Faculty of Humanities, Tomas Bata University in Zlín, Zlín, Czech Republic We read the article titled “Internal mammary sentinel lymph node biopsy: abandon or persist?” by Qiu et al with high interest. This was an excellent paper regarding the contemporary management of internal mammary lymph nodes (IMLN in early-stage breast cancer1 and we would like to take this opportunity to comment on this paper.There are several unresolved questions regarding early-stage breast management including axillary staging, clear resection margin, or IMLN.2–4 We have been focusing on the issues of IMLN for almost a decade and just recently published our data regarding IMLN management. We absolutely agree that one has to carefully balance the benefit and potential risks of biopsy or radiotherapy of IMLN.  Authors' reply Peng-Fei Qiu, Yong-Sheng WangBreast Cancer Center, Shandong Cancer Hospital Affiliated to Shandong University, Jinan, People’s Republic of China  We appreciate the letter from Professors Vrana and Gatek regarding our article titled “Internal mammary sentinel lymph node biopsy: abandon or persist?”.1 We have been following their publications regarding internal mammary lymph nodes (IMLN management since the publication of their article titled “Prognostic influence of internal mammary node drainage in patients with early-stage breast cancer” in December 20162 and we share their interest on this topic.  View the original paper by Qiu and colleagues.

  4. Reducing power consumption while synchronizing a plurality of compute nodes during execution of a parallel application

    Science.gov (United States)

    Archer, Charles J [Rochester, MN; Blocksome, Michael A [Rochester, MN; Peters, Amanda E [Cambridge, MA; Ratterman, Joseph D [Rochester, MN; Smith, Brian E [Rochester, MN

    2012-04-17

    Methods, apparatus, and products are disclosed for reducing power consumption while synchronizing a plurality of compute nodes during execution of a parallel application that include: beginning, by each compute node, performance of a blocking operation specified by the parallel application, each compute node beginning the blocking operation asynchronously with respect to the other compute nodes; reducing, for each compute node, power to one or more hardware components of that compute node in response to that compute node beginning the performance of the blocking operation; and restoring, for each compute node, the power to the hardware components having power reduced in response to all of the compute nodes beginning the performance of the blocking operation.

  5. Reducing power consumption while synchronizing a plurality of compute nodes during execution of a parallel application

    Science.gov (United States)

    Archer, Charles J [Rochester, MN; Blocksome, Michael A [Rochester, MN; Peters, Amanda A [Rochester, MN; Ratterman, Joseph D [Rochester, MN; Smith, Brian E [Rochester, MN

    2012-01-10

    Methods, apparatus, and products are disclosed for reducing power consumption while synchronizing a plurality of compute nodes during execution of a parallel application that include: beginning, by each compute node, performance of a blocking operation specified by the parallel application, each compute node beginning the blocking operation asynchronously with respect to the other compute nodes; reducing, for each compute node, power to one or more hardware components of that compute node in response to that compute node beginning the performance of the blocking operation; and restoring, for each compute node, the power to the hardware components having power reduced in response to all of the compute nodes beginning the performance of the blocking operation.

  6. Implementing asyncronous collective operations in a multi-node processing system

    Science.gov (United States)

    Chen, Dong; Eisley, Noel A.; Heidelberger, Philip; Kumar, Sameer; Salapura, Valentina; Steinmacher-Burow, Burkhard

    2014-07-08

    A method, system, and computer program product are disclosed for implementing an asynchronous collective operation in a multi-node data processing system. In one embodiment, the method comprises sending data to a plurality of nodes in the data processing system, broadcasting a remote get to the plurality of nodes, and using this remote get to implement asynchronous collective operations on the data by the plurality of nodes. In one embodiment, each of the nodes performs only one task in the asynchronous operations, and each nodes sets up a base address table with an entry for a base address of a memory buffer associated with said each node. In another embodiment, each of the nodes performs a plurality of tasks in said collective operations, and each task of each node sets up a base address table with an entry for a base address of a memory buffer associated with the task.

  7. Arm morbidity following sentinel lymph node biopsy or axillary lymph node dissection: a study from the Danish Breast Cancer Cooperative Group

    DEFF Research Database (Denmark)

    Husted, Madsen A.; Haugaard, K.; Soerensen, J.

    2008-01-01

    BACKGROUND: Sentinel lymph node biopsy was implemented in the treatment of early breast cancer with the aim of reducing shoulder and arm morbidity. Relatively few prospective studies have been published where the morbidity was assessed by clinical examination. Very few studies have examined...... lymph node biopsy with node negative patients having a lymph node dissection of levels I and II of the axilla, we found significant increase in arm volume among the patients who had an axillary dissection. Only minor, but significant, differences in shoulder mobility were observed comparing the two...... groups of node negative patients. Highly significant difference was found comparing sensibility. Comparing the morbidity in node positive patients who had a one-step axillary dissection with patients having a two-step procedure (sentinel lymph node biopsy followed by delayed axillary dissection) revealed...

  8. 14 CFR 415.115 - Flight safety.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Flight safety. 415.115 Section 415.115... TRANSPORTATION LICENSING LAUNCH LICENSE Safety Review and Approval for Launch of an Expendable Launch Vehicle From a Non-Federal Launch Site § 415.115 Flight safety. (a) Flight safety analysis. An applicant's...

  9. 14 CFR 417.107 - Flight safety.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Flight safety. 417.107 Section 417.107... TRANSPORTATION LICENSING LAUNCH SAFETY Launch Safety Responsibilities § 417.107 Flight safety. (a) Flight safety... safety system that satisfies subpart D of this part as follows, unless § 417.125 applies. (1) In the...

  10. 14 CFR 121.387 - Flight engineer.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Flight engineer. 121.387 Section 121.387..., FLAG, AND SUPPLEMENTAL OPERATIONS Airman and Crewmember Requirements § 121.387 Flight engineer. No... holding a current flight engineer certificate. For each airplane type certificated after January 1, 1964...

  11. Radiation investigations during space flight

    International Nuclear Information System (INIS)

    Akatov, A.Yu.; Nevzgodina, L.V.; Sakovich, V.A.; Fekher, I.; Deme, Sh.; Khashchegan, D.

    1986-01-01

    Results of radiation investigations during ''Salyut-6'' orbital station flight are presented. The program of studying the environmental radioactivity at the station included ''Integral'' and ''Pille'' experiments. In the course of the ''Integral'' experiment absorbed dose distributions of cosmic radiation and heavy charged particle fluence for long time intervals were studied. Method, allowing one to study dose distributions and determine individual doses for any time interval rapidity and directly on board the station was tested in the course of ''Pille'' experiment for the first time. Attention is paid to measuring equipment. Effect of heavy charged particles on the cellular structure of air-dry Lactuca sativa lettuce seeds was studied in the course of radiobiological experiments conducted at ''Salyut-6'' station. It is shown, that with the increase of flight duration the frequency of cells with chromosomal aberrations increases

  12. Time-of-flight spectrometers

    International Nuclear Information System (INIS)

    Carrico, J.P.

    1976-01-01

    The flight time of an ion in an inhomogeneous, oscillatory electric field (IOFE) is an m/e-dependent property of this field and is independent of the initial position and velocity. The d.c. component of the equation of motion for an ion in the IOFE describes a harmonic oscillation of constant period. When ions oscillate for many periods with one species overtaking another the motion may no longer be truly periodic although the resulting period or 'quasi-period' still remains independent of the initial conditions. This period or 'quasi-period' is used in the time-of-flight mass spectrometer described. The principle of operation is also described and both analytical and experimental results are reported. (B.D.)

  13. ALICE Time of Flight Module

    CERN Multimedia

    The Time-Of-Flight system of ALICE consists of 90 such modules, each containing 15 or 19 Multigap Resistive Plate Chamber (MRPC) strips. This detector is used for identification of charged particles. It measures with high precision (50 ps) the time of flight of charged particles and therefore their velocity. The curvature of the particle trajectory inside the magnetic field gives the momentum, thus the particle mass is calculated and the particle is identified The MRPC is a stack of resistive glass plates, separated from each other by nylon fishing line. The mass production of the chambers (~1600, covering a surface of 150 m2) was done at INFN Bologna, while the first prototypes were bult at CERN.

  14. CFD applications in hypersonic flight

    Science.gov (United States)

    Edwards, T. A.

    1992-01-01

    Design studies are underway for a variety of hypersonic flight vehicles. The National Aero-Space Plane will provide a reusable, single-stage-to-orbit capability for routine access to low earth orbit. Flight-capable satellites will dip into the atmosphere to maneuver to new orbits, while planetary probes will decelerate at their destination by atmospheric aerobraking. To supplement limited experimental capabilities in the hypersonic regime, CFD is being used to analyze the flow about these configurations. The governing equations include fluid dynamic as well as chemical species equations, which are solved with robust upwind differencing schemes. Examples of CFD applications to hypersonic vehicles suggest an important role this technology will play in the development of future aerospace systems. The computational resources needed to obtain solutions are large, but various strategies are being exploited to reduce the time required for complete vehicle simulations.

  15. Flight test trajectory control analysis

    Science.gov (United States)

    Walker, R.; Gupta, N.

    1983-01-01

    Recent extensions to optimal control theory applied to meaningful linear models with sufficiently flexible software tools provide powerful techniques for designing flight test trajectory controllers (FTTCs). This report describes the principal steps for systematic development of flight trajectory controllers, which can be summarized as planning, modeling, designing, and validating a trajectory controller. The techniques have been kept as general as possible and should apply to a wide range of problems where quantities must be computed and displayed to a pilot to improve pilot effectiveness and to reduce workload and fatigue. To illustrate the approach, a detailed trajectory guidance law is developed and demonstrated for the F-15 aircraft flying the zoom-and-pushover maneuver.

  16. BRITTLE CULM16 (BRITTLE NODE) is required for the formation of secondary cell walls in rice nodes

    Institute of Scientific and Technical Information of China (English)

    WANG Ying; WANG Jiu-lin; GUO Xiu-ping; ZHANG Xin; LEI Cai-lin; CHENG Zhi-jun; WAN Jian-min; REN Yu-long; CHEN Sai-hua; XU Yang; ZHOU Kun-neng; ZHANG Long; MING Ming; WU Fu-qing; LIN Qi-bing

    2017-01-01

    Plant cell walls constitute the skeletal structures of plant bodies, and thus confer lodging resistance for grain crops. While the basic cell wall synthesis machinery is relatively well established now, our understanding of how the process is regulated remains limited and fragmented. In this study, we report the identification and characterization of the novel rice (Oryza sativa L.) brittle culm16 (brittle node; bc16) mutant. The brittle node phenotype of the bc16 mutant appears exclusively at nodes, and resembles the previously reported bc5 mutant. Combined histochemical staining and electron microscopy assays revealed that in the bc16 mutant, the secondary cell wall formation and thickening of node sclerenchyma tissues are seriously affected after heading. Furthermore, cell wall composition assays revealed that the bc16 mutation led to a significant reduction in cellulose and lignin contents. Using a map-based cloning approach, the bc16 locus is mapped to an approximately 1.7-Mb region of chromosome 4. Together, our findings strengthen evidence for discretely spatial differences in the secondary cell wall formation within plant bodies.

  17. The Prognostic Value of Lymph Nodes Dissection Number on Survival of Patients with Lymph Node-Negative Gastric Cancer

    Directory of Open Access Journals (Sweden)

    Wu Song

    2014-01-01

    Full Text Available Objective. The study was designed to explore the prognostic value of examined lymph node (LN number on survival of gastric cancer patients without LN metastasis. Methods. Between August 1995 and January 2011, 300 patients who underwent gastrectomy with D2 lymphadenectomy for LN-negative gastric cancer were reviewed. Patients were assigned to various groups according to LN dissection number or tumor invasion depth. Some clinical outcomes, such as overall survival, operation time, length of stay, and postoperative complications, were compared among all groups. Results. The overall survival time of LN-negative GC patients was 50.2±30.5 months. Multivariate analysis indicated that LN dissection number (P30. Besides, it was not correlated with operation time, transfusion volume, length of postoperative stay, or postoperative complication incidence (P>0.05. Conclusions. The number of examined lymph nodes is an independent prognostic factor of survival for patients with lymph node-negative gastric cancer. Sufficient dissection of lymph nodes is recommended during surgery for such population.

  18. 14 CFR 23.865 - Fire protection of flight controls, engine mounts, and other flight structure.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire protection of flight controls, engine... controls, engine mounts, and other flight structure. Flight controls, engine mounts, and other flight... they are capable of withstanding the effects of a fire. Engine vibration isolators must incorporate...

  19. 14 CFR 121.412 - Qualifications: Flight instructors (airplane) and flight instructors (simulator).

    Science.gov (United States)

    2010-01-01

    ... (airplane) and flight instructors (simulator). 121.412 Section 121.412 Aeronautics and Space FEDERAL... OPERATIONS Training Program § 121.412 Qualifications: Flight instructors (airplane) and flight instructors (simulator). (a) For the purposes of this section and § 121.414: (1) A flight instructor (airplane) is a...

  20. X-1A in flight with flight data superimposed

    Science.gov (United States)

    1953-01-01

    This photo of the X-1A includes graphs of the flight data from Maj. Charles E. Yeager's Mach 2.44 flight on December 12, 1953. (This was only a few days short of the 50th anniversary of the Wright brothers' first powered flight.) After reaching Mach 2.44, then the highest speed ever reached by a piloted aircraft, the X-1A tumbled completely out of control. The motions were so violent that Yeager cracked the plastic canopy with his helmet. He finally recovered from a inverted spin and landed on Rogers Dry Lakebed. Among the data shown are Mach number and altitude (the two top graphs). The speed and altitude changes due to the tumble are visible as jagged lines. The third graph from the bottom shows the G-forces on the airplane. During the tumble, these twice reached 8 Gs or 8 times the normal pull of gravity at sea level. (At these G forces, a 200-pound human would, in effect, weigh 1,600 pounds if a scale were placed under him in the direction of the force vector.) Producing these graphs was a slow, difficult process. The raw data from on-board instrumentation recorded on oscillograph film. Human computers then reduced the data and recorded it on data sheets, correcting for such factors as temperature and instrument errors. They used adding machines or slide rules for their calculations, pocket calculators being 20 years in the future. Three second generation Bell Aircraft Corporations X-1s were built, though four were requested. They were the X-1A (48-1384); X-1B (48-1385); X-1C (canceled and never built); X-1D (48-1386). These aircraft were similar to the X-1s, except they were five feet longer, had conventional canopies, and were powered by Reaction Motors, Inc. XLR11-RM-5 rocket engines. The RM-5, like the previous engines, had no throttle and was controlled by igniting one or more of the four thrust chambers at will. The original program outline called for the X-1A and X-1B to be used for dynamic stability and air loads investigations. The X-1D was to be used