WorldWideScience

Sample records for flexible test station

  1. Materials Test Station

    Data.gov (United States)

    Federal Laboratory Consortium — When completed, the Materials Test Station at the Los Alamos Neutron Science Center will meet mission need. MTS will provide the only fast-reactor-like irradiation...

  2. Studies Of Residual Flexibility And Vibration Testing

    Science.gov (United States)

    Admire, John R.; Tinker, Michael L.; Bookout, Paul S.; Ivey, Edward W.

    1995-01-01

    Collection of reports presents theoretical and experimental studies in which concept of residual flexibility applied to modal vibration testing and verification of mathematical models of vibrations of flexible structure constrained by another structure. "Residual flexibility" denotes that part of interface flexibility due to mode shapes out of frequency range of test. Studies directed toward assessing residual-flexibility approach as substitute for fixed-base vibrational testing of payloads installed in spacecraft.

  3. Testing EDM of Total Stations

    Directory of Open Access Journals (Sweden)

    Cirbus Ján

    2001-03-01

    Full Text Available The paper is devoted to testing electrooptical distance measuring devices (EDM built in total stations, than can be used for various tasks in the contemporary geodetic works. A rich market offer and availability of these universal measuring systems with satisfying distance range, excellent accuracy and other parameters, make total stations as dominant terrestrial geodetic instruments.For succesfully applying these instruments, above all for relliable distance measurements, the stability of the modulation frequency is the most important pre-condition. In the article, therefore, there are given some methods to verify the modulation frequency stability. In addition, some ways for determining the EDM distance constant and periodical corrections of the phase measuring unit are introduced for 4 types of EDM : LEICA 1700L, TOPCON GTS6A, TOPCON GTS2, C.ZEISS ELTA50. It were also investigated their possibilities for precise distance survey. Values of the determined constants and periodical corrections are presented in Tab. 2.Based on the investigation results of the 4 EDM types and using the values m obtained for different distances S, equations of the a posteriori standard deviations in form : m = (a+b.S were derived too.

  4. Automation for a base station stability testing

    OpenAIRE

    2016-01-01

    This Batchelor’s thesis was commissioned by Oy LM Ericsson Ab Oulu. The aim of it was to help to investigate and create a test automation solution for the stability testing of the LTE base station. The main objective was to create a test automation for a predefined test set. This test automation solution had to be created for specific environments and equipment. This work included creating the automation for the test cases and putting them to daily test automation jobs. The key factor...

  5. Cosmic ray test station for ATLAS RPC

    CERN Document Server

    Pietra, M Della; Canale, V; Caprio, M A; Carlino, G; Conventi, F; De Asmundis, R; Iengo, P; Patricelli, S; Romanó, L; Sekhniaidze, G; Della Volpe, D

    2003-01-01

    We describe the facility for RPC test with cosmic rays, designed and built at the laboratory of INFN and University of Naples. Trigger and tracking systems consist of a scintillator hodoscope and two drift chambers with track reconstruction resolution of similar to 400 mum. Trigger is provided by the twofold coincidence of scintillators covering a surface of 1 m**2. Two step motors move chambers synchronously along the station for RPC scanning. Up to eight RPCs can be tested simultaneously.

  6. Flexible Ablators Char Depths LHMEL Test Results

    Science.gov (United States)

    White, Susan; Qu, Vince; Fan, Wendy; Stackpoole, Mairead; Thornton, Jeremy

    2012-01-01

    Char and pyrolysis zone depths give physical evidence of peak temperature reached in depth: The pyrolyzing material acts as a temperature indicator within its characteristic thermal decomposition range. A matrix of novel flexible ablators were laser tested in one component of material screening for NASA Entry, Descent and Landing research for future Mars missions. LHMEL tests were run both on virgin materials, and on previously charred materials for a dual pulse simulation of the heating due to aerocapture followed by atmospheric entry. The test models were machined to expose the cross-sections. Char measurements were made at three locations near the center of the exposed area. Data are presented showing the char depths developed in these flexible materials, grouped by reinforcing fiber and pyrolyzing material type.

  7. Fuel Cell Stations Automate Processes, Catalyst Testing

    Science.gov (United States)

    2010-01-01

    Glenn Research Center looks for ways to improve fuel cells, which are an important source of power for space missions, as well as the equipment used to test fuel cells. With Small Business Innovation Research (SBIR) awards from Glenn, Lynntech Inc., of College Station, Texas, addressed a major limitation of fuel cell testing equipment. Five years later, the company obtained a patent and provided the equipment to the commercial world. Now offered through TesSol Inc., of Battle Ground, Washington, the technology is used for fuel cell work, catalyst testing, sensor testing, gas blending, and other applications. It can be found at universities, national laboratories, and businesses around the world.

  8. A probe station for testing silicon sensors

    CERN Multimedia

    Caraban Gonzalez, Noemi

    2017-01-01

    A probe station for testing silicon sensors. The probe station is located inside a dark box that can keep away light during the measurement. The set-up is located in the DSF (Department Silicon Facility). The golden plate is the "chuck" where the sensor is usually placed on. With the help of "manipulators", thin needles can be precisely positioned that can contact the sensor surface. Using these needles and the golden chuck, a high voltage can be applied to the sensor to test its behaviour under high voltage. We will use the silicon sensors that we test here for building prototypes of a highly granular sandwich calorimeter, the CMS HGC (Highly granular Calorimeter) upgrade for High-Luminosity LHC.

  9. A probe station for testing silicon sensors

    CERN Multimedia

    Ulysse, Fichet

    2017-01-01

    A probe station for testing silicon sensors. The probe station is located inside a dark box that can keep away light during the measurement. The set-up is located in the DSF (Department Silicon Facility). The golden plate is the "chuck" where the sensor is usually placed on. With the help of "manipulators", thin needles can be precisely positioned that can contact the sensor surface. Using these needles and the golden chuck, a high voltage can be applied to the sensor to test its behaviour under high voltage. We will use the silicon sensors that we test here for building prototypes of a highly granular sandwich calorimeter, the CMS HGC (Highly granular Calorimeter) upgrade for High-Luminosity LHC.

  10. Mechanism test bed. Flexible body model report

    Science.gov (United States)

    Compton, Jimmy

    1991-01-01

    The Space Station Mechanism Test Bed is a six degree-of-freedom motion simulation facility used to evaluate docking and berthing hardware mechanisms. A generalized rigid body math model was developed which allowed the computation of vehicle relative motion in six DOF due to forces and moments from mechanism contact, attitude control systems, and gravity. No vehicle size limitations were imposed in the model. The equations of motion were based on Hill's equations for translational motion with respect to a nominal circular earth orbit and Newton-Euler equations for rotational motion. This rigid body model and supporting software were being refined.

  11. High temperature and pressure electrochemical test station

    DEFF Research Database (Denmark)

    Chatzichristodoulou, Christodoulos; Allebrod, Frank; Mogensen, Mogens Bjerg

    2013-01-01

    An electrochemical test station capable of operating at pressures up to 100 bars and temperatures up to 400 ◦C has been established. It enables control of the partial pressures and mass flow of O2, N2, H2, CO2, and H2O in a single or dual environment arrangement, measurements with highly corrosive...... media, as well as localized sampling of gas evolved at the electrodes for gas analysis. A number of safety and engineering design challenges have been addressed. Furthermore, we present a series of electrochemical cell holders that have been constructed in order to accommodate different types of cells......, to the electrochemical characterization of high temperature and pressure alkaline electrolysis cells and the use of pseudo-reference electrodes for the separation of each electrode contribution. A future perspective of various electrochemical processes and devices that can be developed with the use of the established...

  12. Severe Accident Test Station Design Document

    Energy Technology Data Exchange (ETDEWEB)

    Snead, Mary A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Yan, Yong [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Howell, Michael [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Keiser, James R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Terrani, Kurt A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-09-01

    The purpose of the ORNL severe accident test station (SATS) is to provide a platform for evaluation of advanced fuels under projected beyond design basis accident (BDBA) conditions. The SATS delivers the capability to map the behavior of advanced fuels concepts under accident scenarios across various temperature and pressure profiles, steam and steam-hydrogen gas mixtures, and thermal shock. The overall facility will include parallel capabilities for examination of fuels and irradiated materials (in-cell) and non-irradiated materials (out-of-cell) at BDBA conditions as well as design basis accident (DBA) or loss of coolant accident (LOCA) conditions. Also, a supporting analytical infrastructure to provide the data-needs for the fuel-modeling components of the Fuel Cycle Research and Development (FCRD) program will be put in place in a parallel manner. This design report contains the information for the first, second and third phases of design and construction of the SATS. The first phase consisted of the design and construction of an out-of-cell BDBA module intended for examination of non-irradiated materials. The second phase of this work was to construct the BDBA in-cell module to test irradiated fuels and materials as well as the module for DBA (i.e. LOCA) testing out-of-cell, The third phase was to build the in-cell DBA module. The details of the design constraints and requirements for the in-cell facility have been closely captured during the deployment of the out-of-cell SATS modules to ensure effective future implementation of the in-cell modules.

  13. Severe Accident Test Station Activity Report

    Energy Technology Data Exchange (ETDEWEB)

    Pint, Bruce A [ORNL; Terrani, Kurt A [ORNL

    2015-06-01

    Enhancing safety margins in light water reactor (LWR) severe accidents is currently the focus of a number of international R&D programs. The current UO2/Zr-based alloy fuel system is particularly susceptible since the Zr-based cladding experiences rapid oxidation kinetics in steam at elevated temperatures. Therefore, alternative cladding materials that offer slower oxidation kinetics and a smaller enthalpy of oxidation can significantly reduce the rate of heat and hydrogen generation in the core during a coolant-limited severe accident. In the U.S. program, the high temperature steam oxidation performance of accident tolerant fuel (ATF) cladding solutions has been evaluated in the Severe Accident Test Station (SATS) at Oak Ridge National Laboratory (ORNL) since 2012. This report summarizes the capabilities of the SATS and provides an overview of the oxidation kinetics of several candidate cladding materials. A suggested baseline for evaluating ATF candidates is a two order of magnitude reduction in the steam oxidation resistance above 1000ºC compared to Zr-based alloys. The ATF candidates are categorized based on the protective external oxide or scale that forms during exposure to steam at high temperature: chromia, alumina, and silica. Comparisons are made to literature and SATS data for Zr-based alloys and other less-protective materials.

  14. Optimal Coordinated Management of a Plug-In Electric Vehicle Charging Station under a Flexible Penalty Contract for Voltage Security

    Directory of Open Access Journals (Sweden)

    Jip Kim

    2016-07-01

    Full Text Available The increasing penetration of plug-in electric vehicles (PEVs may cause a low-voltage problem in the distribution network. In particular, the introduction of charging stations where multiple PEVs are simultaneously charged at the same bus can aggravate the low-voltage problem. Unlike a distribution network operator (DNO who has the overall responsibility for stable and reliable network operation, a charging station operator (CSO may schedule PEV charging without consideration for the resulting severe voltage drop. Therefore, there is a need for the DNO to impose a coordination measure to induce the CSO to adjust its charging schedule to help mitigate the voltage problem. Although the current time-of-use (TOU tariff is an indirect coordination measure that can motivate the CSO to shift its charging demand to off-peak time by imposing a high rate at the peak time, it is limited by its rigidity in that the network voltage condition cannot be flexibly reflected in the tariff. Therefore, a flexible penalty contract (FPC for voltage security to be used as a direct coordination measure is proposed. In addition, the optimal coordinated management is formulated. Using the Pacific Gas and Electric Company (PG&E 69-bus test distribution network, the effectiveness of the coordination was verified by comparison with the current TOU tariff.

  15. Qualification test for the flexible receiver. Revision 2

    Energy Technology Data Exchange (ETDEWEB)

    Tedeschi, D.J.

    1994-12-12

    This document provides the test plan and procedures to certify and design verify the 42{double_prime} and 4{double_prime}-6{double_prime} Flexible Receiver as a safety class 3 system. The Flexible Receiver will be used by projects W-151 and W-320 for removing equipment from tanks C-106 and AZ-101.

  16. Space Station thermal test bed status and plans

    Science.gov (United States)

    Brady, Timothy K.

    1988-01-01

    The accomplishments, current status, and future plans of the thermal test bed program for Space Station thermal management are discussed. This program is intended to support the design and development of the thermal control systems for the Space Station. The topics discussed include heat pipe radiator evaluation, modular panel tests, two-phase heat transport, and testing of thermal buses using ammonia as the working fluid.

  17. Steam Oxidation Testing in the Severe Accident Test Station

    Energy Technology Data Exchange (ETDEWEB)

    Pint, Bruce A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); McMurray, Jake W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-08-01

    Since 2011, Oak Ridge National Laboratory (ORNL) has been conducting high temperature steam oxidation testing of candidate alloys for accident tolerant fuel (ATF) cladding. These concepts are designed to enhance safety margins in light water reactors (LWR) during severe accident scenarios. In the US ATF community, the Severe Accident Test Station (SATS) has been evaluating candidate materials (including coatings) since 2012. Compared to the current UO2/Zr-based alloy fuel system, alternative cladding materials need to offer slower oxidation kinetics and a smaller enthalpy of oxidation in order to significantly reduce the rate of heat and hydrogen generation in the core during a coolant-limited severe accident. The steam oxidation behavior of candidate materials is a key metric in the evaluation of ATF concepts and also an important input into models. However, prior modeling work of FeCrAl cladding has used incomplete information on the physical properties of FeCrAl. Also, the steam oxidation data being collected at 1200°-1700°C is unique as no prior work has considered steam oxidation of alloys at such high temperatures. In some cases, the results have been difficult to interpret and more fundamental information is needed such as the stability of alumina in flowing steam at 1400°-1500°C. This report summarizes recent work to measure the steam oxidation kinetics of candidate alloys, the evaporation rate of alumina in steam and the development of integral data on FeCrAl compared to conventional Zr-based cladding.

  18. Baseline Testing of the Ultracapacitor Enhanced Photovoltaic Power Station

    Science.gov (United States)

    Eichenberg, Dennis J.; Kolacz, John S.; Tavernelli, Paul F.

    2001-01-01

    The NASA John H. Glenn Research Center is developing an advanced ultracapacitor enhanced photovoltaic power station. Goals of this effort include maximizing photovoltaic power generation efficiency and extending the life of photovoltaic energy storage systems. Unique aspects of the power station include the use of a solar tracker, and ultracapacitors for energy storage. The photovoltaic power station is seen as a way to provide electric power in remote locations that would otherwise not have electric power, provide independence form utility systems, reduce pollution, reduce fossil fuel consumption, and reduce operating costs. The work was done under the Hybrid Power Management (HPM) Program, which includes the Hybrid Electric Transit Bus (HETB), and the E-Bike. The power station complements the E-Bike extremely well in that it permits the charging of the vehicle batteries in remote locations. Other applications include scientific research and medical power sources in isolated regions. The power station is an inexpensive approach to advance the state of the art in power technology in a practical application. The project transfers space technology to terrestrial use via nontraditional partners, and provides power system data valuable for future space applications. A description of the ultracapacitor enhanced power station, the results of performance testing and future power station development plans is the subject of this report. The report concludes that the ultracapacitor enhanced power station provides excellent performance, and that the implementation of ultracapacitors in the power system can provide significant performance improvements.

  19. Probe station for testing of ALICE silicon drift detectors

    CERN Document Server

    Humanic, T J; Piemonte, C; Rashevsky, A; Sugarbaker, E R; Vacchi, A

    2003-01-01

    Large area, 7.25 cm multiplied by 8.76 cm silicon drift detectors have been developed and are in production for the ALICE experiment at LHC. An active area of the detector of more than 50 cm**2 imposes high demands on the quality of processing and raw material. Automated testing procedures have been developed to test detectors before mounting them on the ladders. Probe stations for ALICE SDD testing were designed and built at INFN, Trieste and Ohio State University (OSU). Testing procedures, detector selection criteria and some details of the OSU probe station design are discussed.

  20. Evaluation of accelerated deterioration in NAPTF flexible test pavements

    Institute of Scientific and Technical Information of China (English)

    Kasthurirangan GOPALAKRISHNAN

    2008-01-01

    Previous research studies have successfully demonstrated the use of artificial neural network(ANN)models for predicting critical structural responses and layer moduli of highway flexible pavements.The primary objective of this study was to develop an ANN-based approach for backcalculation of pavement moduli based on heavy weight deflectometer(HWD)test data,especially in the analysis of airport flexible pavements subjected to new generation aircraft(NGA).Two medium-strength subgrade flexible test sections,at the National Airport Pavement Test Facility(NAPTF),were modeled using a finite element(FE) based pavement analysis program,which can consider the non-linear stress-dependent behavior of pavement geomaterials.A multi-layer,feed-forward network which uses an error-backpropagation algorithm was trained to approximate the HWD backcalculation function using the FE program generated synthetic database.At the NAPTF,test sections were subjected to Boeing 777 (B777)trafficking on one lane and Boeing 747(B747)trafficking on the other lane using a test machine.To monitor the effect of traffic and climatic variations on pavement structural responses.HWD tests were conducted on the traffieked lanes and on the untraffieked centerline of test sections as trafficking progressed.The trained ANN models were successfully applied on the actual HWD test data acquired at the NAPTF to predict the asphalt concrete moduli and non-1inear subgrade moduli of the medium-strength subgrade flexible test sections.

  1. Flexibility.

    Science.gov (United States)

    Humphrey, L. Dennis

    1981-01-01

    Flexibility is an important aspect of all sports and recreational activities. Flexibility can be developed and maintained by stretching exercises. Exercises designed to develop flexibility in ankle joints, knees, hips, and the lower back are presented. (JN)

  2. Commercial Test of Flexible Dual-Riser Catalytic Cracking Process

    Institute of Scientific and Technical Information of China (English)

    Tang Haitao; Wang Longyan; Wang Guoliang; Zhang Lixin; Wei Jialu; Chen Zhenghong; Teng Tiancan; Sun Zhonghang

    2003-01-01

    The technical features and commercial test results of flexible dual-riser fluidized catalytic cracking(FDFCC) process are presented for refiners to choose an efficient process to upgrade FCC naphtha and boostpropylene production in a RFCC unit. The commercial test results indicate that the olefin content of catalyti-25% and RON increased by 0.5-2 units in a RFCC unit. In addition, propylene yield and the production ratioof diesel to gasoline can also be remarkably enhanced in the RFCC unit.

  3. Application of flexible scope in large testing laboratories

    Directory of Open Access Journals (Sweden)

    Carina Di Candia

    2011-04-01

    Full Text Available According as the international definition of Flexible Scope, a laboratory must demonstrate face with the accreditation body that it has the knowledge, experience and competence to work within the full range of its flexible scope, as well as possessing suitable laboratory environments and equipment. The laboratory must also demonstrate that it has a management system in place that can control its proposed approach while continuing to comply with the requirements of ISO 17025:2005. In case of UKAS (Unites Kingdom Accreditation Service, prior to offering accreditation for flexible scope they must have a high degree of confidence that the staff are technically competent and that the management system controlling certain key processes as development, review, validation and authorization.LATU apply these requirements since 2004 as "Unified Tests". Until this date, LATU was doing the same type of tests in different materials departments using different equipment, personal, and testing quality control. In order to that were defined cross disciplinary groups to analyze this topic approaching in personal competence and quality control tests improvement, and resource's decrease. For example, LATU has the Unified Test Tensile Strength accredited by UKAS in: corrugated and solid fiberboard, paper board, linerboard, cork plugs, plastic bags, plastic sheeting, paper, woven fabrics, plastic woven bags and woven plastic. As a result of the Unified Tests was generated a general unified manage procedure with unified criteria's, responsibilities and actions. Was written a unique testing procedure not only with the actual flexible scope and the flexibilities limits but also the compliance requirements of ISO 17025 and the accreditations body methodology. We could decrease the amount of documentation to control. Was defined the methodology and implemented periodicaly internal inter comparisons between departments in order to valid the unified tests and has a unique

  4. Testing for voter rigging in small polling stations

    CERN Document Server

    Jiménez, Raúl; Klimek, Peter

    2016-01-01

    Since the 1970s there has been a large number of countries that combine formal democratic institutions with authoritarian practices. Although in such countries the ruling elites may receive considerable voter support they often employ several manipulation tools to control election outcomes. A common practice of these regimes is the coercion and mobilization of a significant amount of voters to guarantee the electoral victory. This electoral irregularity is known as voter rigging, distinguishing it from vote rigging, which involves ballot stuffing or stealing. Here we develop a statistical test to quantify to which extent the results of a particular election display traces of voter rigging. Our key hypothesis is that small polling stations are more susceptible to voter rigging, because it is easier to identify opposing individuals, there are less eye witnesses, and supposedly less visits from election observers. We devise a general statistical method for testing whether voting behavior in small polling station...

  5. Performance Improvement of a Measurement Station for Superconducting Cable Test

    CERN Document Server

    Arpaia, P; Montenero, G; Le Naour, S

    2012-01-01

    A fully digital system, improving measurements flexibility, integrator drift, and current control of superconducting transformers for cable test, is proposed. The system is based on a high-performance integration of Rogowski coil signal and a flexible direct control of the current into the secondary windings. This allows state-of-the-art performance to be overcome by means of out-of-the-shelf components: on a full-scale of 32 kA, current measurement resolution of 1 A, stability below 0.25 Amin-1, and controller ripple less than 50 ppm. The system effectiveness has been demonstrated experimentally on the superconducting transformer of the Facility for the Research of Superconducting Cables at the European Organization for Nuclear Research (CERN).

  6. Space Station CMIF extended duration metabolic control test

    Science.gov (United States)

    Schunk, Richard G.; Bagdigian, Robert M.; Carrasquillo, Robyn L.; Ogle, Kathryn Y.; Wieland, Paul O.

    1989-01-01

    The Space Station Extended Duration Metabolic Control Test (EMCT) was conducted at the MSFC Core Module Integration Facility. The primary objective of the EMCT was to gather performance data from a partially-closed regenerative Environmental Control and Life Support (ECLS) system functioning under steady-state conditions. Included is a description of the EMCT configuration, a summary of events, a discussion of anomalies that occurred during the test, and detailed results and analysis from individual measurements of water and gas samples taken during the test. A comparison of the physical, chemical, and microbiological methods used in the post test laboratory analyses of the water samples is included. The preprototype ECLS hardware used in the test, providing an overall process description and theory of operation for each hardware item. Analytical results pertaining to a system level mass balance and selected system power estimates are also included.

  7. Probe Station and Near-Field Scanner for Testing Antennas

    Science.gov (United States)

    Zaman, Afroz; Lee, Richard Q.; Darby, William G.; Barr, Philip J.; Miranda, Felix A.; Lambert, Kevin

    2006-01-01

    A facility that includes a probe station and a scanning open-ended waveguide probe for measuring near electromagnetic fields has been added to Glenn Research Center's suite of antenna-testing facilities, at a small fraction of the cost of the other facilities. This facility is designed specifically for nondestructive characterization of the radiation patterns of miniaturized microwave antennas fabricated on semiconductor and dielectric wafer substrates, including active antennas that are difficult to test in traditional antenna-testing ranges because of fragility, smallness, or severity of DC-bias or test-fixture requirements. By virtue of the simple fact that a greater fraction of radiated power can be captured in a near-field measurement than in a conventional far-field measurement, this near-field facility is convenient for testing miniaturized antennas with low gains.

  8. Space Station Freedom solar array panels plasma interaction test facility

    Science.gov (United States)

    Martin, Donald F.; Mellott, Kenneth D.

    1989-01-01

    The Space Station Freedom Power System will make extensive use of photovoltaic (PV) power generation. The phase 1 power system consists of two PV power modules each capable of delivering 37.5 KW of conditioned power to the user. Each PV module consists of two solar arrays. Each solar array is made up of two solar blankets. Each solar blanket contains 82 PV panels. The PV power modules provide a 160 V nominal operating voltage. Previous research has shown that there are electrical interactions between a plasma environment and a photovoltaic power source. The interactions take two forms: parasitic current loss (occurs when the currect produced by the PV panel leaves at a high potential point and travels through the plasma to a lower potential point, effectively shorting that portion of the PV panel); and arcing (occurs when the PV panel electrically discharges into the plasma). The PV solar array panel plasma interaction test was conceived to evaluate the effects of these interactions on the Space Station Freedom type PV panels as well as to conduct further research. The test article consists of two active solar array panels in series. Each panel consists of two hundred 8 cm x 8 cm silicon solar cells. The test requirements dictated specifications in the following areas: plasma environment/plasma sheath; outgassing; thermal requirements; solar simulation; and data collection requirements.

  9. metrological performance improvement of a superconducting cable test station

    CERN Document Server

    Montenero, Giuseppe; Ballarino, Amalia

    The work presented in this PhD thesis concerns the metrological performance improvement of a superconducting cable test station based on superconducting transformers. The main cable’s parameter to be assessed –as a function of temperature and magnetic field– is the critical current, i.e. beyond this limit the phase transition to the normal state occurs. Ramping the current at levels in the order of the tens of kA can be achieved with superconducting transformers at moderate capital and operational cost. But, issues such as (i) accurate/precise measurements and (ii) monitoring of the secondary current during the device operation have to be addressed. In this regard, the goals of the thesis are the design, prototyping, and validation of a new cryogenic current transducer and effective monitoring system for test stations transformer-based. Among the available transducers for current sensing at room temperature, the DC current transformer (DCCT) provides measurement accuracy in the order of the hundreds of ...

  10. Abrasion test of flexible protective materials on hydraulic structures

    Directory of Open Access Journals (Sweden)

    Xin WANG

    2014-01-01

    Full Text Available In this study, several kinds of flexible protective materials sprayed with polyurea elastomers (hereinafter referred to as polyurea elastomer protective material were adopted to meet the abrasion resistance requirement of hydraulic structures, and their abrasion resistances against the water flow with suspended load or bed load were studied systematically through tests. Natural basalt stones were adopted as the abrasive for simulation of the abrasion effect of the water flow with bed load, and test results indicate that the basalt stone is suitable for use in the abrasion resistance test of the flexible protective material. The wear process of the polyurea elastomer protective material is stable, and the wear loss is linear with the time of abrasion. If the wear thickness is regarded as the abrasion resistance evaluation factor, the abrasion resistance of the 351 pure polyurea is about twice those of pure polyurea with a high level of hardness and aliphatic polyurea, and over five times that of high-performance abrasion-resistant concrete under the abrasion of the water flow with suspended load. It is also about 50 times that of high-performance abrasion-resistant concrete under the abrasion of the water flow with bed load. Overall, the abrasion resistance of pure polyurea presented a decreasing trend with increasing hardness. Pure polyurea with a Shore hardness of D30 has the best abrasion resistance, which is 60 to 70 times that of high-performance abrasion-resistant concrete under the abrasion of the water flow with bed load, and has been recommended, among the five kinds of pure polyurea materials with different hardness, in anti-abrasion protection of hydraulic structures.

  11. HAS AN IMPORTANT TEST BEEN OVERLOOKED?: CLOSURE FLEXIBILITY IN SCHIZOPHRENIA

    Science.gov (United States)

    Butler, Pamela D.; Schechter, Isaac; Revheim, Nadine; Silipo, Gail; Javitt, Daniel C.

    2010-01-01

    Deficits in visual processing are now recognized as a core feature of schizophrenia. In the 1940’s, Louis Thurstone developed a series of tests designed to evaluate specific aspects of visual perceptual processing including the Closure Flexibility Test (CFT), which was designed to measure “the ability to hold a configuration in mind despite distraction.” The present study evaluated patients’ performance on this task and its relationship to other tests of neuropsychological function, particularly to a measure of sustained visual attention. Thirty-nine patients with schizophrenia or schizoaffective disorder and 40 controls participated. The CFT was administered both in its original form (10 min) and also in a briefer form (3 min) in which only a portion of stimuli were given. Patients showed highly significant large effect size deficits on both the original (d=1.6) and brief (d=1.2) CFT. Between-group deficits in performance survived covariation for IQ. In addition, the CFT score was significantly related to performance on the MATRICS measure of attention/vigilance, the Continuous Performance Test-Identical Pairs version (CPT-IP). This correlation remained significant even after controlling for non-specific intercorrelations among neurocognitive measures. Results confirm the severity of early visual processing deficits in schizophrenia. In addition, the CFT is a brief, easy to administer alphabet-independent, paper-and-pencil test with established psychometric properties that may be useful as an index of the sustained visual attention construct in schizophrenia. PMID:20110157

  12. Development of Test Protocols for International Space Station Particulate Filters

    Science.gov (United States)

    Green, Robert D.; Vijayakumar, R.; Agui, Juan H.

    2014-01-01

    Air quality control on the International Space Station (ISS) is a vital requirement for maintaining a clean environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of gravitational settling. The ISS Environmental Control and Life Support System (ECLSS) uses a filtration system that has been in use for over 14 years and has proven to meet this challenge. The heart of this system is a traditional High- Efficiency Particulate Air (HEPA) filter configured to interface with the rest of the life support elements and provide effective cabin filtration. Over the years, the service life of these filters has been re-evaluated based on limited post-flight tests of returned filters and risk factors. On earth, a well designed and installed HEPA filter will last for several years, e.g. in industrial and research clean room applications. Test methods for evaluating these filters are being developed on the basis of established test protocols used by the industry and the military. This paper will discuss the test methods adopted and test results on prototypes of the ISS filters. The results will assist in establishing whether the service life can be extended for these filters. Results from unused filters that have been in storage will also be presented to ascertain the shelf life and performance deterioration, if any and determine if the shelf life may be extended.

  13. Modeling and Control of Flexible HEV Charging Station upgraded with Flywheel Energy Storage

    DEFF Research Database (Denmark)

    Dragicevic, Tomislav; Shafiee, Qobad; Wu, Dan

    2014-01-01

    This paper deals with the design of a fast DC charging station (FCS) for hybrid electric vehicles (HEVs) that is connected at a remote location. Power rating of this new technology can go up to a hundred kW and it represents a main challenge for its broad acceptance in distribution systems...

  14. Development of Test Protocols for International Space Station Particulate Filters

    Science.gov (United States)

    Vijayakumar, R.; Green, Robert D.; Agui, Juan H.

    2015-01-01

    Air quality control on the International Space Station (ISS) is a vital requirement for maintaining a clean environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of gravitational settling. The ISS Environmental Control and Life Support System (ECLSS) uses a filtration system that has been in use for over 14 years and has proven to meet this challenge. The heart of this system is a traditional High-Efficiency Particulate Air (HEPA) filter configured to interface with the rest of the life support elements and provide effective cabin filtration. The filter element for this system has a non-standard cross-section with a length-to-width ratio (LW) of 6.6. A filter test setup was designed and built to meet industry testing standards. A CFD analysis was performed to initially determine the optimal duct geometry and flow configuration. Both a screen and flow straighter were added to the test duct design to improve flow uniformity and face velocity profiles were subsequently measured to confirm. Flow quality and aerosol mixing assessments show that the duct flow is satisfactory for the intended leak testing. Preliminary leak testing was performed on two different ISS filters, one with known perforations and one with limited use, and results confirmed that the testing methods and photometer instrument are sensitive enough to detect and locate compromised sections of an ISS BFE.Given the engineering constraints in designing spacecraft life support systems, it is anticipated that non-industry standard filters will be required in future designs. This work is focused on developing test protocols for testing the ISS BFE filters, but the methodology is general enough to be extended to other present and future spacecraft filters. These techniques for characterizing the test duct and perform leak testing

  15. Methodology for Flight Relevant Arc-Jet Testing of Flexible Thermal Protection Systems

    Science.gov (United States)

    Mazaheri, Alireza; Bruce, Walter E., III; Mesick, Nathaniel J.; Sutton, Kenneth

    2013-01-01

    A methodology to correlate flight aeroheating environments to the arc-jet environment is presented. For a desired hot-wall flight heating rate, the methodology provides the arcjet bulk enthalpy for the corresponding cold-wall heating rate. A series of analyses were conducted to examine the effects of the test sample model holder geometry to the overall performance of the test sample. The analyses were compared with arc-jet test samples and challenges and issues are presented. The transient flight environment was calculated for the Hypersonic Inflatable Aerodynamic Decelerator (HIAD) Earth Atmospheric Reentry Test (HEART) vehicle, which is a planned demonstration vehicle using a large inflatable, flexible thermal protection system to reenter the Earth's atmosphere from the International Space Station. A series of correlations were developed to define the relevant arc-jet test environment to properly approximate the HEART flight environment. The computed arcjet environments were compared with the measured arc-jet values to define the uncertainty of the correlated environment. The results show that for a given flight surface heat flux and a fully-catalytic TPS, the flight relevant arc-jet heat flux increases with the arc-jet bulk enthalpy while for a non-catalytic TPS the arc-jet heat flux decreases with the bulk enthalpy.

  16. Towards Intelligence and Flexibility of Learning and Knowledge Testing Environments

    Directory of Open Access Journals (Sweden)

    Nerijus AUKSTAKALNIS

    2006-02-01

    Full Text Available The proposed goal oriented knowledge acquisition and assessment are based on the flexible educational model and allows to implement an adaptive control of the enhanced learning process according to the requirements of student's knowledge level, his state of cognition and subject learning history. The enhanced learner knowledge model specifies how the cognition state of the user will be achieved step by step. The use case actions definition is a starting point of the specification, which depends on different levels of learning scenarios and user cognition sub goals. The use case actions specification is used as a basis to set the requirements for service software specification and attributes of learning objects respectively. The paper presents the enhanced architecture of the student self-evaluation and on-line assessment system TestTool. The system is explored as an assessment engine capable of supporting and improving the individualized intelligent goal oriented self-instructional and simulation based mode of learning, grounded on the GRID distributed service architecture.

  17. Comparison of Ambient Noise From Two Station Designs, Evaluating USArray's Transportable and Flexible Arrays in the Pacific Northwest

    Science.gov (United States)

    Pfeifer, M.; Alvarez, M.; Woodward, R.; Yang, Z.

    2009-12-01

    The USArray program within the National Science Foundation-funded Earthscope program is comprised of two portable broadband seismic projects; the Transportable Array (TA), and the Flexible Array (FA). The TA consists of 400 stations occupy locations within the United States on a nominal 70 km spacing for a period of approximately 24 months. As a network, these TA stations roll from west to east so that within 10 years the entire lower 48 states will have been occupied by the TA network. As a complementary component of USArray, the FA pool of instruments is comprised of 1200 active-source, 120 short-period and 326 broadband portable stations. These instruments are used by Principal Investigator-driven studies which focus on geologic targets within the TA footprint. Currently the TA network is transitioning from the Rocky Mountains into the Great Plains. The FA currently has four experiments installed. In this study we quantify the overall performance of these two tandem networks using a controlled set of continuous recordings in Western Washington. We compare the background noise levels between the standard deep TA and shallow FA broadband sensor vault system. We use McNamara’s probability density function (PDF) analysis as the basis of the comparison. We combine the network wide PDF’s of each network for a period of over 600 days of contemporaneous recordings. Preliminary analysis using data from 28 TA stations in western Washington and 47 nearby FA stations from the CAFE experiment (Abers, et al. Eos Trans. AGU 88(52), Fall Meet. Suppl. S43D-07), show that the TA stations are quieter at periods below 20 seconds by about 12 dB on the horizontal components. The vertical components for both the TA and FA are equivalent for periods below 5 seconds. At higher frequencies (> 2 Hz), however, the FA shallower vault is quieter by approximately 10 dB on both the vertical and horizontal components. The question addressed is, what is contributing to the difference in

  18. The Space Station Photovoltaic Panels Plasma Interaction Test Program: Test plan and results

    Science.gov (United States)

    Nahra, Henry K.; Felder, Marian C.; Sater, Bernard L.; Staskus, John V.

    1989-01-01

    The Plasma Interaction Test performed on two space station solar array panels is addressed. This includes a discussion of the test requirements, test plan, experimental set-up, and test results. It was found that parasitic current collection was insignificant (0.3 percent of the solar array delivered power). The measured arcing threshold ranged from -210 to -457 V with respect to the plasma potential. Furthermore, the dynamic response of the panels showed the panel time constant to range between 1 and 5 microsec, and the panel capacitance to be between .01 and .02 microF.

  19. The Space Station photovoltaic panels plasma interaction test program - Test plan and results

    Science.gov (United States)

    Nahra, Henry K.; Felder, Marian C.; Sater, Bernard L.; Staskus, John V.

    1990-01-01

    The plasma Interaction Test performed on two space station solar array panels is addressed. This includes a discussion of the test requirements, test plan, experimental set-up, and test results. It was found that parasitic current collection was insignificant (0.3 percent of the solar array delivered power). The measured arcing threshold ranged from -210 to -457 V with respect to the plasma potential. Furthermore, the dynamic response of the panels showed the panel time constant to range between 1 and 5 microsec, and the panel capacitance to be between .01 and .02 microF.

  20. Large Optic Drying Station: Summary of Dryer Certification Tests

    Energy Technology Data Exchange (ETDEWEB)

    Barbee, T W; Ayers, S L; Ayers, M J

    2009-08-28

    The purpose of this document is to outline the methodology used to baseline and maintain the cleanliness status of the newly built and installed Large Optic Cleaning Station (LOCS). The station has currently been in use for eleven months; and after many cleaning studies and implementation of resulting improvements appears to be cleaning optics to a level that is acceptable for the fabrication of Nano-Laminates.

  1. Verification Test of the Change-of-Pace Station Wagon.

    Science.gov (United States)

    1980-07-01

    Cleveland, Ohio, by Electric Vehicles Associates. It is a converted AMC Pacer station wagon. It is powered by 20 6-volt batteries that are connected to... Electric Station Wagon is an electrified version of an AMC Pacer wagon, converted by Electric Vehicle Associates, Inc., 9100 Bank St., Cleveland, OH...of Electric and Hybrid Vehicles isa. OECLASSIFICATION/DOWNGRADING SCHEDULE IS. DISTRIBUTION STATEMENT (of thil Report) Approved for public release

  2. Space-Based Reconfigurable Software Defined Radio Test Bed Aboard International Space Station

    Science.gov (United States)

    Reinhart, Richard C.; Lux, James P.

    2014-01-01

    The National Aeronautical and Space Administration (NASA) recently launched a new software defined radio research test bed to the International Space Station. The test bed, sponsored by the Space Communications and Navigation (SCaN) Office within NASA is referred to as the SCaN Testbed. The SCaN Testbed is a highly capable communications system, composed of three software defined radios, integrated into a flight system, and mounted to the truss of the International Space Station. Software defined radios offer the future promise of in-flight reconfigurability, autonomy, and eventually cognitive operation. The adoption of software defined radios offers space missions a new way to develop and operate space transceivers for communications and navigation. Reconfigurable or software defined radios with communications and navigation functions implemented in software or VHDL (Very High Speed Hardware Description Language) provide the capability to change the functionality of the radio during development or after launch. The ability to change the operating characteristics of a radio through software once deployed to space offers the flexibility to adapt to new science opportunities, recover from anomalies within the science payload or communication system, and potentially reduce development cost and risk by adapting generic space platforms to meet specific mission requirements. The software defined radios on the SCaN Testbed are each compliant to NASA's Space Telecommunications Radio System (STRS) Architecture. The STRS Architecture is an open, non-proprietary architecture that defines interfaces for the connections between radio components. It provides an operating environment to abstract the communication waveform application from the underlying platform specific hardware such as digital-to-analog converters, analog-to-digital converters, oscillators, RF attenuators, automatic gain control circuits, FPGAs, general-purpose processors, etc. and the interconnections among

  3. 49 CFR 192.731 - Compressor stations: Inspection and testing of relief devices.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Compressor stations: Inspection and testing of...) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.731 Compressor stations: Inspection and testing of relief devices. (a) Except for rupture...

  4. Robust Medical Test Evaluation Using Flexible Bayesian Semiparametric Regression Models

    Directory of Open Access Journals (Sweden)

    Adam J. Branscum

    2013-01-01

    Full Text Available The application of Bayesian methods is increasing in modern epidemiology. Although parametric Bayesian analysis has penetrated the population health sciences, flexible nonparametric Bayesian methods have received less attention. A goal in nonparametric Bayesian analysis is to estimate unknown functions (e.g., density or distribution functions rather than scalar parameters (e.g., means or proportions. For instance, ROC curves are obtained from the distribution functions corresponding to continuous biomarker data taken from healthy and diseased populations. Standard parametric approaches to Bayesian analysis involve distributions with a small number of parameters, where the prior specification is relatively straight forward. In the nonparametric Bayesian case, the prior is placed on an infinite dimensional space of all distributions, which requires special methods. A popular approach to nonparametric Bayesian analysis that involves Polya tree prior distributions is described. We provide example code to illustrate how models that contain Polya tree priors can be fit using SAS software. The methods are used to evaluate the covariate-specific accuracy of the biomarker, soluble epidermal growth factor receptor, for discerning lung cancer cases from controls using a flexible ROC regression modeling framework. The application highlights the usefulness of flexible models over a standard parametric method for estimating ROC curves.

  5. Principal facts for about 16,000 gravity stations in the Nevada test site and vicinity

    Science.gov (United States)

    Harris, R. N.; Ponce, D. A.; Oliver, H. W.; Healey, D. L.

    The Nevada Test Site (NTS) and vicinity includes portions of the Goldfield, Caliente, Death Valley, and Las Vegas. This report documents and consolidates previously published and recently compiled gravity data to establish a gravity data base of about 16,000 stations for the NTS and vicinity. While compiling data sets, redundant stations and stations having doubtful locations or gravity values were excluded. Details of compiling the gravity data sets are discussed in later sections. Where feasible, an accuracy code has been assigned to each station so that the accuracy or reliability of each station can be evaluated. This data base was used in preparing complete Bouguer and isostatic gravity maps of the NTS and vicinity. Since publication of the complete Bouguer gravity map, additional data were incorporated into the isostatic gravity map. Gravity data were compiled from five sources: 14,183 stations from the U.S. Geological Survey (USGS), 326 stations from Exploration Data Consultants (EDCON) of Denver, Colorado, 906 stations from the Los Alamos National Laboratory (LANL), 212 stations from the University of Texas at Dallas (UTD), and 48 stations from the Defense Mapping Agency (DMA). This investigation is an effort to study several areas for potential storage of high-level radioactive waste. Gravity stations established under YMP are shown. The objective of this gravity survey was to explore for the presence of plutons.

  6. Manufacturing and testing flexible microfluidic devices with optical and electrical detection mechanisms

    NARCIS (Netherlands)

    Ivan, M.G.; Vivet, F.; Meinders, E.R.

    2010-01-01

    Flexible microfluidic devices made of poly(dimethylsiloxane) (PDMS) were manufactured by soft lithography, and tested in detection of ionic species using optical absorption spectroscopy and electrical measurements. PDMS was chosen due to its flexibility and ease of surface modification by exposure

  7. Manufacturing and testing flexible microfluidic devices with optical and electrical detection mechanisms

    NARCIS (Netherlands)

    Ivan, M.G.; Vivet, F.; Meinders, E.R.

    2010-01-01

    Flexible microfluidic devices made of poly(dimethylsiloxane) (PDMS) were manufactured by soft lithography, and tested in detection of ionic species using optical absorption spectroscopy and electrical measurements. PDMS was chosen due to its flexibility and ease of surface modification by exposure t

  8. Realisation and instrumentation of high current power station for superconducting cables testing; Realisation et instrumentation d'une station fort courant pour le test de cables supraconducteurs

    Energy Technology Data Exchange (ETDEWEB)

    Regnaud, S

    2000-05-01

    This report deals with the designing of a high current station able to test electric properties of superconductors. This test station will be used for testing the superconducting wires of large hadron collider detectors in CERN. The high current test station will have to generate high intensity continuous current in a magnetic field of 0 to 5 tesla and in temperature conditions of 4.2 K. The length of wire samples submitted to the uniform magnetic field is 300 mm and the installation is fitted with equipment able to measure the magnetic field perpendicular to either faces of the wire. The peculiarity of this station is to use a superconducting transformer in order to generate the high current. The first part of this work recalls important notions concerning superconductivity. The second part presents the high current station by describing the superconducting transformer and the sample-holder. We have studied the designing of a transformer able to yield a secondary current whose intensity reaches 100 kA, such intensity generates powerful electromagnetic forces (566 kN/m) in case of defect, so the sample-holder has to be carefully design to bear them. The third part presents the cryogenic component of the station, the instrumentation of the sample-holder and the method used to measure secondary currents. In the last part we present the performance of a prototype transformer, this prototype is able to deliver a 22 kA secondary current for a 160 A primary current, the uncertainty on the measured value of the secondary current is about 3%.

  9. Flexible electronic feedback using the virtues of progress testing

    NARCIS (Netherlands)

    Muijtjens, A.M.; Timmermans, I.; Donkers, J.; Peperkamp, R.; Medema, H.; Cohen-Schotanus, J.; Thoben, A.; Wenink, A.C.; van der Vleuten, C.P.

    2010-01-01

    The potential richness of the feedback for learners and teachers is one of the educational advantages of progress tests (PTs). Every test administration yields information on a student's knowledge level in each sub-domain of the test (cross-sectional information), and it adds a next point to the cor

  10. 基于PLC的柔性制造系统供料站设计%Design of feeding station of the flexible manufacture system based on PLC

    Institute of Scientific and Technical Information of China (English)

    张顺星; 师亚娟

    2015-01-01

    供料站是柔性制造系统中的起始工作站,起着向整个系统中各工作站提供原料的作用。该文提出以西门子S7-200 PLC作为控制器,以SMC气动元件作为执行机构的柔性制造系统供料站设计方案,详细论述了供料站的硬件系统构成、气动控制回路、程序设计流程及实现方法。%Feeding station is the starting station in flexible manufacture system, which played the role of supplying other workstations in the whole system with raw material. In this paper, providing the design of feeding station of flexible manufacture system with the Siemens S7 -200 PLC as the controller and SMC pneumatic components as the executive mechanism. The feeding station was described in detail the hardware system structure, pneumatic control loop, the program design process and implementation meth-od.

  11. Flexible thermal cycle test equipment for concentrator solar cells

    Science.gov (United States)

    Hebert, Peter H [Glendale, CA; Brandt, Randolph J [Palmdale, CA

    2012-06-19

    A system and method for performing thermal stress testing of photovoltaic solar cells is presented. The system and method allows rapid testing of photovoltaic solar cells under controllable thermal conditions. The system and method presents a means of rapidly applying thermal stresses to one or more photovoltaic solar cells in a consistent and repeatable manner.

  12. Automation Hooks Architecture Trade Study for Flexible Test Orchestration

    Science.gov (United States)

    Lansdowne, Chatwin A.; Maclean, John R.; Graffagnino, Frank J.; McCartney, Patrick A.

    2010-01-01

    We describe the conclusions of a technology and communities survey supported by concurrent and follow-on proof-of-concept prototyping to evaluate feasibility of defining a durable, versatile, reliable, visible software interface to support strategic modularization of test software development. The objective is that test sets and support software with diverse origins, ages, and abilities can be reliably integrated into test configurations that assemble and tear down and reassemble with scalable complexity in order to conduct both parametric tests and monitored trial runs. The resulting approach is based on integration of three recognized technologies that are currently gaining acceptance within the test industry and when combined provide a simple, open and scalable test orchestration architecture that addresses the objectives of the Automation Hooks task. The technologies are automated discovery using multicast DNS Zero Configuration Networking (zeroconf), commanding and data retrieval using resource-oriented Restful Web Services, and XML data transfer formats based on Automatic Test Markup Language (ATML). This open-source standards-based approach provides direct integration with existing commercial off-the-shelf (COTS) analysis software tools.

  13. Experimental testing of flexible barriers for containment of debris flows

    Science.gov (United States)

    DeNatale, Jay S.; Iverson, Richard M.; Major, Jon J.; LaHusen, Richard G.; Fliegel, Gregg L.; Duffy, John D.

    1999-01-01

    In June 1996, six experiments conducted at the U.S. Geological Survey Debris Flow Flume demonstrated that flexible, vertical barriers constructed of wire rope netting can stop small debris flows. All experimental debris flows consisted of water-saturated gravelly sand with less than two percent finer sediment by weight. All debris flows had volumes of about 10 cubic meters, masses of about 20 metre tons, and impact velocities of 5 to 9 meters per second. In four experiments, the debris flow impacted pristine, unreformed barriers of varying design; in the other two experiments, the debris flow impacted barriers already loaded with sediment from a previous flow. Differences in barrier design led to differences in barrier performance. Experiments were conducted with barriers constructed of square-mesh wire-rope netting with 30centimeter, 20centimeter, and 15 centimeter mesh openings as well as 30centimeter diameter interlocking steel rings. In all cases, sediment cascading downslope at the leading edge of the debris flows tended to spray through the nets. Nets fitted with finer-mesh chain link or chicken wire liners contained more sediment than did unlined nets, and a ring net fitted with a synthetic silt screen liner contained nearly 100 percent of the sediment. Irreversible net displacements of up to 2 meters and friction brake engagement on the support and anchor cables dissipated some of the impact energy. However, substantial forces developed in the steel support columns and the lateral and tie-back anchor cables attached to these columns. As predicted by elementary mechanics, the anchor cables experienced larger tensile forces when the support columns were hinged at the base rather than bolted rigidly to the foundation. Measured loads in the lateral anchor cables exceeded those in the tie-back anchor cables and the load cell capacity of 45 kilo-Newtons. Measurements also indicated that the peak loads in the tie- back anchors were highly transient and occurred at

  14. Comparative Analysis and Pedestrian Simulation Evaluation on Emergency Evacuation Test Methods for Urban Rail Transit Stations

    Directory of Open Access Journals (Sweden)

    Zijia Wang

    2012-11-01

    Full Text Available The emergency evacuation test method of rail transit station not only affects the operation safety of the station, but it also has significant influence on the scale and cost of the station. A reasonable test method should guarantee both the safety of evacuation and that the investment is neither excessive nor too conservative. The paper compares and analyzes the differences of the existing emergency evacuation test methods of rail stations in China and other regions on the evacuation load, evacuation time calculation and the capacity of egress components, etc. Based on the field survey analysis, the desired velocity distribution of pedestrians in various station facilities and the capacity of egress components have been obtained, and then the parameters of pedestrian simulation tool were calibrated. By selecting a station for the case study, an evacuation simulation model has been established, where five evacuation scenarios have been set according to different specifications and the simulation results have been carefully analyzed. Through analyzing the simulation results, some modification proposals of the current emergency evacuation test method in the design manual have been considered, including taking into account the section passenger volume, walking time on escalators and stairs of the platform, and the condition in which the escalator most critical to evacuation should be considered as out of service.

  15. Test of Seal System for Flexible Pipe End Fitting

    DEFF Research Database (Denmark)

    Banke, Lars; Jensen, Thomas Gregers

    1999-01-01

    by compression of the gaskets, thus using the geometry to establish a seal towards the inner liner of the pipe and the steel sleeve of the end fitting. This paper describes how the seal system of an end fitting can be tested using an autoclave. By regulating temperature and pressure, the seal system can...

  16. Realization of station for testing asynchronous three-phase motors

    Science.gov (United States)

    Wróbel, A.; Surma, W.

    2016-08-01

    Nowadays, you cannot imagine the construction and operation of machines without the use of electric motors [13-15]. The proposed position is designed to allow testing of asynchronous three-phase motors. The position consists of a tested engine and the engine running as a load, both engines combined with a mechanical clutch [2]. The value of the load is recorded by measuring shaft created with Strain Gauge Bridge. This concept will allow to study the basic parameters of the engines, visualization motor parameters both vector and scalar controlled, during varying load drive system. In addition, registration during the variable physical parameters of the working electric motor, controlled by a frequency converter or controlled by a contactor will be possible. Position is designed as a teaching and research position to characterize the engines. It will be also possible selection of inverter parameters.

  17. Integrated Circuit Readout for the Silicon Sensor Test Station

    CERN Document Server

    Atkin, E; Silaev, A; Fedenko, A; Karmanov, D; Merkin, M; Voronin, A

    2009-01-01

    Various chips for the silicon sensors measurements are described. These chips are based on 0.35 um and 0.18um CMOS technology. Several analog chips together with self-trigger /derandomizer one allow to measure silicon sensors designed for different purposes. Tracking systems, calorimeters, particle charge measurement system and other application sensors can be investigated by the integrated circuit readout with laser or radioactive sources. Also electrical parameters of silicon sensors can be studied by such test setup.

  18. Baseline and Verification Tests of the Electric Vehicle Associates’ Current Fare Station Wagon.

    Science.gov (United States)

    1983-01-01

    the EVA Current Fare Wagon. The EVA Current Fare Wagon is a 1980 Ford Fairmont station wagon which has been converted to an electric vehicle . The...standard Ford Fairmont station wagon which has been converted to an electric vehicle (Figures 1 anil 2). It is powered I% 22 6-V lead-acid batteries2...D-R132 549 BASELINE AND VERIFICATION TESTS OF THE ELECTRIC VEHICLE 112 ASSOCIATES’ CURRE..(U) ARMY MOBILITY EQUIPMENT RESEARCH AIND DEVELOPMENT

  19. Development of a flexible test-bed for robotics, telemanipulation and servicing research

    Science.gov (United States)

    Davies, Barry F.

    1989-01-01

    The development of a flexible operation test-bed, based around a commercially available ASEA industrial robot is described. The test-bed was designed to investigate fundamental human factors issues concerned with the unique problems of robotic manipulation in the hostile environment of Space.

  20. 14th Annual international meeting of wind turbine test stations: Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    1994-11-01

    These proceedings are of the 14th Annual International Meeting of Test Stations. As the original charter states these meetings are intended to be an international forum for sharing wind turbine testing experiences. By sharing their experiences they can improve testing skills and techniques. As with all new industries the quality of the products is marked by how well they learn from their experiences and incorporate this learning into the next generation of products. The test station`s role in this process is to provide accurate information to the companies they serve. This information is used by designers to conform and improve their designs. It is also used by certification agencies for confirming the quality of these designs. By sharing of experiences they are able to accomplished these goals, serve these customers better and ultimately improve the international wind energy industry.

  1. Testing - Smart strategy for safety and mission quality. [Space Station Freedom

    Science.gov (United States)

    Rodney, George A.

    1991-01-01

    The paper is concerned with the need for a comprehensive test plan for the Space Station Freedom (SST) that would fully verify specification compliance and be based on an error budget. In particular, attention is given to some lessons learned from other NASA programs and the principal challenges for SSF testing, including phase C/D/E agreements, testing parameters, phase testing, and the human element. The importance of close teamwork between the NASA/Contractor systems engineers and assurance engineers is emphasized.

  2. Flexible Local Load Controller for Fast ElectricVehicle Charging Station Supplemented with Flywheel Energy Storage System

    DEFF Research Database (Denmark)

    Dragicevic, Tomislav; SUN, BO; Schaltz, Erik

    2014-01-01

    of dedicated flywheel energy storage system (FESS) within the charging station and compensating some of the adverse effects of high power charging is explored in this paper. Although sharing some similarities with vehicle to grid (V2G) technology, the principal advantage of this strategy is the fact that many...

  3. Test on the 30kW Vibrating Wave-power Station Accepted in China

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    To meet the demand of island residents on the electric power for their daily lives, a 30kW vibrating wavepower station, designed and built by the Oceanic Technology Research Institute of China National Bureau of Ocean, is presently conducted with test in Jimo city of Shangdong province, and accepted by China National Bureau of Ocean and China's Academy of Science.

  4. 49 CFR 192.739 - Pressure limiting and regulating stations: Inspection and testing.

    Science.gov (United States)

    2010-10-01

    ... Maintenance § 192.739 Pressure limiting and regulating stations: Inspection and testing. (a) Each pressure... standpoint of capacity and reliability of operation for the service in which it is employed; (3) Except as... prevent unsafe operation of the pipeline considering its operating and maintenance history and MAOP. [35...

  5. International Space Station Alpha's bearing, motor, and roll ring module developmental testing and results

    Science.gov (United States)

    Obrien, David L.

    1994-01-01

    This paper presents the design and developmental testing associated with the bearing, motor, and roll ring module (BMRRM) used for the beta rotation axis on International Space Station Alpha (ISSA). The BMRRM with its controllers located in the electronic control unit (ECU), provides for the solar array pointing and tracking functions as well as power and signal transfer across a rotating interface.

  6. Design and Testing of a Flexible Solar Generator for On-Orbit Verification Misison

    Science.gov (United States)

    Langendorf, Sven; Brunner, Sebastian; Zajac, Kai

    2014-06-01

    Novel flexible, lightweight and highly efficient Cu(In,Ga)Se2 (CIGSe) thin film solar cells on polyimide (PI) foil substrate were the starting point for the development of a flexible solar generator.The presented solar generator consists of an aluminium support structure and a drum on which the CIGSe thin film solar cells are rolled up. When releasing the mechanism a flexible solar array of 128 mm x 344 mm will be self-deployed, without requiring any electric power. When deployed the solar array is self-locked. This paper presents a short overview of the baseline design requirements for a potential On-Orbit verification mission, the developed design, results of the first verification tests and an outlook on a possible scalability.

  7. Mechanism Design and Testing of a Self-Deploying Structure Using Flexible Composite Tape Springs

    Science.gov (United States)

    Footdale, Joseph N.; Murphey, Thomas W.

    2014-01-01

    The detailed mechanical design of a novel deployable support structure that positions and tensions a membrane optic for space imagining applications is presented. This is a complex three-dimensional deployment using freely deploying rollable composite tape spring booms that become load bearing structural members at full deployment. The deployment tests successfully demonstrate a new architecture based on rolled and freely deployed composite tape spring members that achieve simultaneous deployment without mechanical synchronization. Proper design of the flexible component mounting interface and constraint systems, which were critical in achieving a functioning unit, are described. These flexible composite components have much potential for advancing the state of the art in deployable structures, but have yet to be widely adopted. This paper demonstrates the feasibility and advantages of implementing flexible composite components, including the design details on how to integrate with required traditional mechanisms.

  8. Corrective Action Plan for Corrective Action Unit 490: Station 44 Burn Area, Tonopah Test Range, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    K. B. Campbell

    2002-04-01

    Corrective Action Unit (CAU) 490, Station 44 Burn Area is located on the Tonopah Test Range (TTR). CAU 490 is listed in the Federal Facility Agreement and Consent Order (FFACO, 1996) and includes for Corrective Action Sites (CASs): (1) Fire Training Area (CAS 03-56-001-03BA); (2) Station 44 Burn Area (CAS RG-56-001-RGBA); (3) Sandia Service Yard (CAS 03-58-001-03FN); and (4) Gun Propellant Burn Area (CAS 09-54-001-09L2).

  9. Corrective action decision document, Second Gas Station, Tonopah test range, Nevada (Corrective Action Unit No. 403)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-11-01

    This Corrective Action Decision Document (CADD) for Second Gas Station (Corrective Action Unit [CAU] No. 403) has been developed for the U.S. Department of Energy`s (DOE) Nevada Environmental Restoration Project to meet the requirements of the Federal Facility Agreement and Consent Order (FFACO) of 1996 as stated in Appendix VI, {open_quotes}Corrective Action Strategy{close_quotes} (FFACO, 1996). The Second Gas Station Corrective Action Site (CAS) No. 03-02-004-0360 is the only CAS in CAU No. 403. The Second Gas Station CAS is located within Area 3 of the Tonopah Test Range (TTR), west of the Main Road at the location of former Underground Storage Tanks (USTs) and their associated fuel dispensary stations. The TTR is approximately 225 kilometers (km) (140 miles [mi]) northwest of Las Vegas, Nevada, by air and approximately 56 km (35 mi) southeast of Tonopah, Nevada, by road. The TTR is bordered on the south, east, and west by the Nellis Air Force Range and on the north by sparsely populated public land administered by the Bureau of Land Management and the U.S. Forest Service. The Second Gas Station CAS was formerly known as the Underground Diesel Tank Site, Sandia Environmental Restoration Site Number 118. The gas station was in use from approximately 1965 to 1980. The USTs were originally thought to be located 11 meters (m) (36 feet [ft]) east of the Old Light Duty Shop, Building 0360, and consisted of one gasoline UST (southern tank) and one diesel UST (northern tank) (DOE/NV, 1996a). The two associated fuel dispensary stations were located northeast (diesel) and southeast (gasoline) of Building 0360 (CAU 423). Presently the site is used as a parking lot, Building 0360 is used for mechanical repairs of vehicles.

  10. Strength assessment of a cryostat used by the hollow electron test station.

    CERN Document Server

    Efremov, Filip

    2015-01-01

    The following report explains the work I have done on my summer student work project and the experience I have gained during the process. The work consisted of a strength assessment of a cryogenic vacuum insulated vessel according to European regulations. The cryogenic vacuum insulated vessel is used for the cooling of the solenoids. The solenoids are used in the hollow electron test station and create the magnetic fields used for testing electron guns and validating the concept of a hollow electron lens.

  11. Provision of Flexible Load Control by Multi-Flywheel-Energy-Storage System in Electrical Vehicle Charging Stations

    DEFF Research Database (Denmark)

    Sun, Bo; Dragicevic, Tomislav; Andrade, Fabio

    2015-01-01

    Electrical vehicle (EV) chargers are going to occupy a considerable portion of total energy consumption in the future smart grid. Fast charging stations (FCS), as the most demanding representatives of charging infrastructure, will be requested to provide some ancillary services to the power system...... in order to support basic electrical operation. This paper proposes a local implementation of a hysteresis-based aggregation algorithm for coordinated control of multiple stations that can provide functions such as peak shaving, spinning reserves, frequency control, regulation and load following. Local...... stability. Finally, corresponding hardware in the loop results based on dSPACE1006 platform have been reported in order to verify the validity of proposed approach....

  12. A PC-based Flexible Solution for Virtual Instrumentation of a Multi-Purpose Test Bed

    Directory of Open Access Journals (Sweden)

    Benatzky Christian

    2006-11-01

    Full Text Available The aim of the paper is to give an overview of a test bed set up for lightweight flexible structures. The purpose of the test bed is to compare different concepts for suppressing structural vibrations. It is demonstrated that such a complex measurement and actuation task can be easily implemented on a single PC using standard software like Matlab/SIMULINK® with a minimum of custom hardware. With the help of this PC standard engineering tasks like measuring, identification of transfer functions, as well as controller design and implementation in soft real-time can be carried out easily (rapid prototyping. The resulting system is flexible and scalable, enabling an engineer to perform all the above mentioned tasks for a given test object within minimum time. Additionally, the utilization of Matlab/SIMULINK® facilitates the realization of a versatile virtual instrumentation system which is easy to use and may also be remote-controlled.

  13. Tests of shielding effectiveness of Kevlar and Nextel onboard the International Space Station and the Foton-M3 capsule.

    Science.gov (United States)

    Pugliese, M; Bengin, V; Casolino, M; Roca, V; Zanini, A; Durante, M

    2010-08-01

    Radiation assessment and protection in space is the first step in planning future missions to the Moon and Mars, where mission and number of space travelers will increase and the protection of the geomagnetic shielding against the cosmic radiation will be absent. In this framework, the shielding effectiveness of two flexible materials, Kevlar and Nextel, were tested, which are largely used in the construction of spacecrafts. Accelerator-based tests clearly demonstrated that Kevlar is an excellent shield for heavy ions, close to polyethylene, whereas Nextel shows poor shielding characteristics. Measurements on flight performed onboard of the International Space Station and of the Foton-M3 capsule have been carried out with special attention to the neutron component; shielded and unshielded detectors (thermoluminescence dosemeters, bubble detectors) were exposed to a real radiation environment to test the shielding properties of the materials under study. The results indicate no significant effects of shielding, suggesting that thin shields in low-Earth Orbit have little effect on absorbed dose.

  14. Infrared Heater Used in Qualification Testing of International Space Station Radiators

    Science.gov (United States)

    Ziemke, Robert A.

    2004-01-01

    Two heat rejection radiator systems for the International Space Station (ISS) have undergone thermal vacuum qualification testing at the NASA Glenn Research Center (GRC), Plum Brook Station, Sandusky, Ohio. The testing was performed in the Space Power Facility (SPF), the largest thermal vacuum chamber in the world. The heat rejection system radiator was tested first; it removes heat from the ISS crew living quarters. The second system tested was the photovoltaic radiator (PVR), which rejects heat from the ISS photovoltaic arrays and the electrical power-conditioning equipment. The testing included thermal cycling, hot- and cold-soaked deployments, thermal gradient deployments, verification of the onboard heater controls, and for the PVR, thermal performance tests with ammonia flow. Both radiator systems are orbital replacement units for ease of replacement on the ISS. One key to the success of these tests was the performance of the infrared heater system. It was used in conjunction with a gaseous-nitrogen-cooled cryoshroud in the SPF vacuum chamber to achieve the required thermal vacuum conditions for the qualification tests. The heater, which was designed specifically for these tests, was highly successful and easily met the test requirements. This report discusses the heating requirements, the heater design features, the design approach, and the mathematical basis of the design.

  15. Phenotypic flexibility as a measure of health: the optimal nutritional stress response test.

    Science.gov (United States)

    Stroeve, Johanna H M; van Wietmarschen, Herman; Kremer, Bas H A; van Ommen, Ben; Wopereis, Suzan

    2015-05-01

    Nutrition research is struggling to demonstrate beneficial health effects, since nutritional effects are often subtle and long term. Health has been redefined as the ability of our body to cope with daily-life challenges. Physiology acts as a well-orchestrated machinery to adapt to the continuously changing environment. We term this adaptive capacity "phenotypic flexibility." The phenotypic flexibility concept implies that health can be measured by the ability to adapt to conditions of temporary stress, such as physical exercise, infections or mental stress, in a healthy manner. This may offer a more sensitive way to assess changes in health status of healthy subjects. Here, we performed a systematic review of 61 studies applying different nutritional stress tests to quantify health and nutritional health effects, with the objective to define an optimal nutritional stress test that has the potential to be adopted as the golden standard in nutrition research. To acknowledge the multi-target role of nutrition, a relevant subset of 50 processes that govern optimal health, with high relevance to diet, was used to define phenotypic flexibility. Subsequently, we assessed the response of biomarkers related to this subset of processes to the different challenge tests. Based on the obtained insights, we propose a nutritional stress test composed of a high-fat, high-caloric drink, containing 60 g palm olein, 75 g glucose and 20 g dairy protein in a total volume of 400 ml. The use of such a standardized nutritional challenge test in intervention studies is expected to demonstrate subtle improvements of phenotypic flexibility, thereby enabling substantiation of nutritional health effects.

  16. Automation Hooks Architecture for Flexible Test Orchestration - Concept Development and Validation

    Science.gov (United States)

    Lansdowne, C. A.; Maclean, John R.; Winton, Chris; McCartney, Pat

    2011-01-01

    The Automation Hooks Architecture Trade Study for Flexible Test Orchestration sought a standardized data-driven alternative to conventional automated test programming interfaces. The study recommended composing the interface using multicast DNS (mDNS/SD) service discovery, Representational State Transfer (Restful) Web Services, and Automatic Test Markup Language (ATML). We describe additional efforts to rapidly mature the Automation Hooks Architecture candidate interface definition by validating it in a broad spectrum of applications. These activities have allowed us to further refine our concepts and provide observations directed toward objectives of economy, scalability, versatility, performance, severability, maintainability, scriptability and others.

  17. Electro-Mechanical Testing of Conductive Materials Used in Flexible Electronics

    Directory of Open Access Journals (Sweden)

    Megan J Cordill

    2016-02-01

    Full Text Available The use of flexible electronics has increased in recent years. In order to have robust and long lasting flexible displays and sensors, the combined electro-mechanical behavior needs to be assessed. The most common method to determine electrical and mechanical behavior of conductive thin films used in flexible electronics is the fragmentation test, or uniaxial tensile straining of the film and substrate. When performed in situ fracture and deformation behavior can be determined. The use of in situ electrical resistance measurements can be informative about the crack onset strain of brittle layers, such as transparent conductors, or the stretchability of metal interconnects. The combination of in situ electrical measurements with in situ X-ray or confocal laser scanning microscopy can provide even more information about the failure mechanisms of the material systems. Lattice strains and stresses can be measured with X-rays, while cracking and buckle delaminations can be studied with confocal laser scanning microscopy. These new combinations of in situ methods will be discussed as well as methods to quantify interfacial properties of conductive thin films on polymer substrates. The combined techniques provide valuable correlated electrical and mechanical data needed to understand failure mechanisms in flexible devices.

  18. Aerothermal Ground Testing of Flexible Thermal Protection Systems for Hypersonic Inflatable Aerodynamic Decelerators

    Science.gov (United States)

    Bruce, Walter E., III; Mesick, Nathaniel J.; Ferlemann, Paul G.; Siemers, Paul M., III; DelCorso, Joseph A.; Hughes, Stephen J.; Tobin, Steven A.; Kardell, Matthew P.

    2012-01-01

    Flexible TPS development involves ground testing and analysis necessary to characterize performance of the FTPS candidates prior to flight testing. This paper provides an overview of the analysis and ground testing efforts performed over the last year at the NASA Langley Research Center and in the Boeing Large-Core Arc Tunnel (LCAT). In the LCAT test series, material layups were subjected to aerothermal loads commensurate with peak re-entry conditions enveloping a range of HIAD mission trajectories. The FTPS layups were tested over a heat flux range from 20 to 50 W/cm with associated surface pressures of 3 to 8 kPa. To support the testing effort a significant redesign of the existing shear (wedge) model holder from previous testing efforts was undertaken to develop a new test technique for supporting and evaluating the FTPS in the high-temperature, arc jet flow. Since the FTPS test samples typically experience a geometry change during testing, computational fluid dynamic (CFD) models of the arc jet flow field and test model were developed to support the testing effort. The CFD results were used to help determine the test conditions experienced by the test samples as the surface geometry changes. This paper includes an overview of the Boeing LCAT facility, the general approach for testing FTPS, CFD analysis methodology and results, model holder design and test methodology, and selected thermal results of several FTPS layups.

  19. Hot Cell Installation and Demonstration of the Severe Accident Test Station

    Energy Technology Data Exchange (ETDEWEB)

    Linton, Kory D. [ORNL; Burns, Zachary M. [ORNL; Terrani, Kurt A. [ORNL; Yan, Yong [ORNL

    2017-08-01

    A Severe Accident Test Station (SATS) capable of examining the oxidation kinetics and accident response of irradiated fuel and cladding materials for design basis accident (DBA) and beyond design basis accident (BDBA) scenarios has been successfully installed and demonstrated in the Irradiated Fuels Examination Laboratory (IFEL), a hot cell facility at Oak Ridge National Laboratory. The two test station modules provide various temperature profiles, steam, and the thermal shock conditions necessary for integral loss of coolant accident (LOCA) testing, defueled oxidation quench testing and high temperature BDBA testing. The installation of the SATS system restores the domestic capability to examine postulated and extended LOCA conditions on spent fuel and cladding and provides a platform for evaluation of advanced fuel and accident tolerant fuel (ATF) cladding concepts. This document reports on the successful in-cell demonstration testing of unirradiated Zircaloy-4. It also contains descriptions of the integral test facility capabilities, installation activities, and out-of-cell benchmark testing to calibrate and optimize the system.

  20. Thermal-hydraulic tests of a recirculation cooling installation for the Rostov nuclear power station

    Science.gov (United States)

    Balunov, B. F.; Balashov, V. A.; Il'in, V. A.; Krayushnikov, V. V.; Lychakov, V. D.; Meshalkin, V. V.; Ustinov, A. N.; Shcheglov, A. A.

    2013-09-01

    Results obtained from thermal-hydraulic tests of the recirculation cooling installation used as part of the air cooling system under the containments of the Rostov nuclear power station Units 3 and 4 are presented. The operating modes of the installation during normal operation (air cooling on the surface of finned tubes), under the conditions of anticipated operational occurrences (air cooling and steam condensation from a steam-air mixture), and during an accident (condensation of pure steam) are considered. Agreement is obtained between the results of tests and calculations carried out according to the recommendations given in the relevant regulatory documents. A procedure of carrying out thermal calculation for the case of steam condensation from a steam-air mixture on the surface of fins is proposed. The possibility of efficient use of the recirculation cooling installation in the system for reducing emergency pressure under the containment of a nuclear power station is demonstrated.

  1. New fuel vault criticality analysis at Chinshan nuclear power station with new approaches to improve the storage flexibility

    Energy Technology Data Exchange (ETDEWEB)

    Huang, P. H., E-mail: u808966@taipower.com.t [Taiwan Power Company, Department of Nuclear Generation, 242 Roosevelt Rd., Sec. 3, Taipei, Taiwan (China)

    2010-10-15

    The Chinshan new fuel vault (NFV) consists of 13 fuel storage racks, each rack may store 10 fuel assemblies. Prior to 2008, the NFV had never been used and the practice by the Taiwan Power Company (TPC) was to temporarily store the fuel assemblies in the shipping containers after received, until the inspection work was performed shortly before the outage, and then assemblies were loaded directly into the spent fuel pool (SFP). Starting from 2009, this practice has been revised since the new fuel contract would only supply a small amount of containers for storage, and the SFP would lose full-core-off load capability soon; therefore, use of NFV to store fuel assemblies following inspection becomes extremely crucial. The original Chinshan NFV criticality analysis was performed for the initial fuel design. Although many new fuel designs had been used (e.g., Atrium-10 reported in PBNC-14), no reanalysis had been performed because it was not anticipated that NFV would be used. Therefore, TPC requested the vendor to perform the analysis for Atrium-10. Originally, the vendor estimated that number of assemblies allowed to be stored would be limited severely to about 60. To enhance storage flexibility, Tpc proposed some new approaches: 1) All assemblies are assumed in vendor's standard method to contain a single limiting lattice for entire fuel length, it is suggested that axially zoned limiting lattices be selected based on characteristics of reloads to be delivered, and this significantly improves flexibility. 2) The maximum k-effective equation used by vendor was corrected (manufacturing tolerances were conservatively mistreated). Also, the vendor typically used 0.95 k-effective as the criterion, it is suggested that NUREG-0800 requirement ({<=}0.98 for optimum moderation conditions) be applied. After several iterations, all the 130 locations are allowed to store fuel. The analysis report has been approved by the authority in June 2008. (Author)

  2. Synthesized Multi-station Tribo-test System for Bio-tribological Evaluation in Vitro

    Institute of Scientific and Technical Information of China (English)

    WU Tonghai; DU Ying; LI Yang; WANG Shuo; ZHANG Zhinan

    2016-01-01

    Tribological tests play an important role on the evaluation of long-term bio-tribological performances of prosthetic materials for commercial fabrication. Those tests focus on the motion simulation of a real joint in vitro with only normal loads and constant velocities, which are far from the real friction behavior of human joints characterized with variable loads and multiple directions. In order to accurately obtain the bio-tribological performances of artificial joint materials, a tribological tester with a miniature four-station tribological system is proposed with four distinctive features. Firstly, comparability and repeatability of a test are ensured by four equal stations of the tester. Secondly, cross-linked scratch between tribo-pairs of human joints can be simulated by using a gear-rack meshing mechanism to produce composite motions. With this mechanism, the friction tracks can be designed by varying reciprocating and rotating speeds. Thirdly, variable loading system is realized by using a ball-screw mechanism driven by a stepper motor, by which loads under different gaits during walking are simulated. Fourthly, dynamic friction force and normal load can be measured simultaneously. The verifications of the performances of the developed tester show that the variable frictional tracks can produce different wear debris compared with one-directional tracks, and the accuracy of loading and friction force is within±5%. Thus the high consistency among different stations can be obtained. Practically, the proposed tester system could provide more comprehensive and accurate bio-tribological evaluations for prosthetic materials.

  3. Synthesized multi-station tribo-test system for bio-tribological evaluation in vitro

    Science.gov (United States)

    Wu, Tonghai; Du, Ying; Li, Yang; Wang, Shuo; Zhang, Zhinan

    2016-07-01

    Tribological tests play an important role on the evaluation of long-term bio-tribological performances of prosthetic materials for commercial fabrication. Those tests focus on the motion simulation of a real joint in vitro with only normal loads and constant velocities, which are far from the real friction behavior of human joints characterized with variable loads and multiple directions. In order to accurately obtain the bio-tribological performances of artificial joint materials, a tribological tester with a miniature four-station tribological system is proposed with four distinctive features. Firstly, comparability and repeatability of a test are ensured by four equal stations of the tester. Secondly, cross-linked scratch between tribo-pairs of human joints can be simulated by using a gear-rack meshing mechanism to produce composite motions. With this mechanism, the friction tracks can be designed by varying reciprocating and rotating speeds. Thirdly, variable loading system is realized by using a ball-screw mechanism driven by a stepper motor, by which loads under different gaits during walking are simulated. Fourthly, dynamic friction force and normal load can be measured simultaneously. The verifications of the performances of the developed tester show that the variable frictional tracks can produce different wear debris compared with one-directional tracks, and the accuracy of loading and friction force is within ±5%. Thus the high consistency among different stations can be obtained. Practically, the proposed tester system could provide more comprehensive and accurate bio-tribological evaluations for prosthetic materials.

  4. Development, Analysis and Testing of the High Speed Research Flexible Semispan Model

    Science.gov (United States)

    Schuster, David M.; Spain, Charles V.; Turnock, David L.; Rausch, Russ D.; Hamouda, M-Nabil; Vogler, William A.; Stockwell, Alan E.

    1999-01-01

    This report presents the work performed by Lockheed Martin Engineering and Sciences (LMES) in support of the High Speed Research (HSR) Flexible Semispan Model (FSM) wind-tunnel test. The test was conducted in order to assess the aerodynamic and aeroelastic character of a flexible high speed civil transport wing. Data was acquired for the purpose of code validation and trend evaluation for this type of wing. The report describes a number of activities in preparing for and conducting the wind-tunnel test. These included coordination of the design and fabrication, development of analytical models, analysis/hardware correlation, performance of laboratory tests, monitoring of model safety issues, and wind-tunnel data acquisition and reduction. Descriptions and relevant evaluations associated with the pretest data are given in sections 1 through 6, followed by pre- and post-test flutter analysis in section 7, and the results of the aerodynamics/loads test in section 8. Finally, section 9 provides some recommendations based on lessons learned throughout the FSM program.

  5. Geometrically Nonlinear Aeroelastic Stability Analysis and Wind Tunnel Test Validation of a Very Flexible Wing

    Directory of Open Access Journals (Sweden)

    Changchuan Xie

    2016-01-01

    Full Text Available VFAs (very flexible aircraft have begun to attract significant attention because of their good flight performances and significant application potentials; however, they also bring some challenges to researchers due to their unusual lightweight designs and large elastic deformations. A framework for the geometrically nonlinear aeroelastic stability analysis of very flexible wings is constructed in this paper to illustrate the unique aeroelastic characteristics and convenient use of these designs in engineering analysis. The nonlinear aeroelastic analysis model includes the geometrically nonlinear structure finite elements and steady and unsteady nonplanar aerodynamic computations (i.e., the nonplanar vortex lattice method and nonplanar doublet-lattice method. Fully nonlinear methods are used to analyse static aeroelastic features, and linearized structural dynamic equations are established at the structural nonlinear equilibrium state to estimate the stability of the system through the quasimode of the stressed and deformed structure. The exact flutter boundary is searched via an iterative procedure. A wind tunnel test is conducted to validate this theoretical analysis framework, and reasonable agreement is obtained. Both the analysis and test results indicate that the geometric nonlinearity of very flexible wings presents significantly different aeroelastic characteristics under different load cases with large deformations.

  6. CFD Analysis of Flexible Thermal Protection System Shear Configuration Testing in the LCAT Facility

    Science.gov (United States)

    Ferlemann, Paul G.

    2014-01-01

    This paper documents results of computational analysis performed after flexible thermal protection system shear configuration testing in the LCAT facility. The primary objectives were to predict the shear force on the sample and the sensitivity of all surface properties to the shape of the sample. Bumps of 0.05, 0.10,and 0.15 inches were created to approximate the shape of some fabric samples during testing. A large amount of information was extracted from the CFD solutions for comparison between runs and also current or future flight simulations.

  7. Ground-based testing of the dynamics of flexible space structures using band mechanisms

    Science.gov (United States)

    Yang, L. F.; Chew, Meng-Sang

    1991-01-01

    A suspension system based on a band mechanism is studied to provide the free-free conditions for ground based validation testing of flexible space structures. The band mechanism consists of a noncircular disk with a convex profile, preloaded by torsional springs at its center of rotation so that static equilibrium of the test structure is maintained at any vertical location; the gravitational force will be directly counteracted during dynamic testing of the space structure. This noncircular disk within the suspension system can be configured to remain unchanged for test articles with the different weights as long as the torsional spring is replaced to maintain the originally designed frequency ratio of W/k sub s. Simulations of test articles which are modeled as lumped parameter as well as continuous parameter systems, are also presented.

  8. LHCb: Test Station for the LHCb Muon Front-End Electronic

    CERN Multimedia

    Polycarpo, E

    2005-01-01

    The LHCb Muon Group has developed the CMOS ASIC CARIOCA to readout its Multiwire Proportional Chambers (MWPC) and GEM detectors, using a rad-hard IBM 0.25um process. Each ASIC holds 8 identical current-mode ASDB channels with individual input thresholds. The Muon detector contains around 120000 physical channels, requiring production of 20000 front-end chips, roughly. CARIOCA has been developed to process MWPC cathode and anode signals and two different versions have been implemented to overcome the requirement of MWP and GEM chambers operation. The test station has been devised to accomplish bipolar tests and to measure characteristics of both CARIOCA versions.

  9. Test and evaluation of the heat recovery incinerator system at Naval Station, Mayport, Florida

    Science.gov (United States)

    1981-05-01

    This report describes test and evaluation of the two-ton/hr heat recovery incinerator (HRI) facility located at Mayport Naval Station, Fla., carried out during November and December 1980. The tests included: (1) Solid Waste: characterization, heating value, and ultimate analysis, (2) Ash: moisture, combustibles, and heating values of both bottom and cyclone ashes; Extraction Procedure toxicity tests on leachates from both bottom and cyclone ashes; trace metals in cyclone particulates, (3) Stack Emissions: particulates (quantity and size distribution), chlorides, oxygen, carbon dioxide, carbon monoxide, and trace elements, and (4) Heat and Mass Balance: all measurements required to carry out complete heat and mass balance calculations over the test period. The overall thermal efficiency of the HRI facility while operating at approximately 1.0 ton/hr was found to be 49% when the primary Btu equivalent of the electrical energy consumed during the test program was included.

  10. Design and testing of the U.S. Space Station Freedom primary propulsion system

    Science.gov (United States)

    Morano, Joseph S.; Delventhal, Rex A.; Chilcot, Kimberly J.

    1992-07-01

    The primary propulsion system (PPS) for the Space Station Freedom is discussed in terms of salient design characteristics and key testing procedures. The rocket engine modules contain reboost and attitude control thrusters, and their designs are illustrated showing the mounting structures, thruster solenoid valves, and thrust chambers. The propellant tank assembly for storing gaseous N pressurant and hydrazine propellant is described as are the system avionics, thruster solenoid valves, and latching isolation valves. PPS testing conducted on the development systems includes the use of a propulsion-module development unit, a development test article, and system qualification testing. Specific test articles include functional heaters, mass/thermal simulated components, flight-quality structures, and software control operations.

  11. International Space Station alpha remote manipulator system workstation controls test report

    Science.gov (United States)

    Ehrenstrom, William A.; Swaney, Colin; Forrester, Patrick

    1994-01-01

    Previous development testing for the space station remote manipulator system workstation controls determined the need for hardware controls for the emergency stop, brakes on/off, and some camera functions. This report documents the results of an evaluation to further determine control implementation requirements, requested by the Canadian Space Agency (CSA), to close outstanding review item discrepancies. This test was conducted at the Johnson Space Center's Space Station Mockup and Trainer Facility in Houston, Texas, with nine NASA astronauts and one CSA astronaut as operators. This test evaluated camera iris and focus, back-up drive, latching end effector release, and autosequence controls using several types of hardware and software implementations. Recommendations resulting from the testing included providing guarded hardware buttons to prevent accidental actuation, providing autosequence controls and back-up drive controls on a dedicated hardware control panel, and that 'latch on/latch off', or on-screen software, controls not be considered. Generally, the operators preferred hardware controls although other control implementations were acceptable. The results of this evaluation will be used along with further testing to define specific requirements for the workstation design.

  12. A flexible and robust soft-error testing system for microelectronic devices and integrated circuits

    Institute of Scientific and Technical Information of China (English)

    王晓辉; 杨振雷; 童腾; 苏弘; 刘杰; 张战刚; 古松; 刘天奇; 孔洁; 赵兴文

    2015-01-01

    Single event effects (SEEs) induced by radiations become a significant reliability challenge for modern elec-tronic systems. To evaluate SEEs susceptibility for microelectronic devices and integrated circuits (ICs), an SEE testing system with flexibility and robustness was developed at Heavy Ion Research Facility in Lanzhou (HIRFL). The system is compatible with various types of microelectronic devices and ICs, and supports plenty of complex and high-speed test schemes and plans for the irradiated devices under test (DUTs). Thanks to the combination of meticulous circuit design and the hardened logic design, the system has additional performances to avoid an overheated situation and irradiations by stray radiations. The system has been tested and verified by experiments for irradiating devices at HIRFL.

  13. Design, Development and Pre-Flight Testing of the Communications, Navigation, and Networking Reconfigurable Testbed (Connect) to Investigate Software Defined Radio Architecture on the International Space Station

    Science.gov (United States)

    Over, Ann P.; Barrett, Michael J.; Reinhart, Richard C.; Free, James M.; Cikanek, Harry A., III

    2011-01-01

    The Communication Navigation and Networking Reconfigurable Testbed (CoNNeCT) is a NASA-sponsored mission, which will investigate the usage of Software Defined Radios (SDRs) as a multi-function communication system for space missions. A softwaredefined radio system is a communication system in which typical components of the system (e.g., modulators) are incorporated into software. The software-defined capability allows flexibility and experimentation in different modulation, coding and other parameters to understand their effects on performance. This flexibility builds inherent redundancy and flexibility into the system for improved operational efficiency, real-time changes to space missions and enhanced reliability/redundancy. The CoNNeCT Project is a collaboration between industrial radio providers and NASA. The industrial radio providers are providing the SDRs and NASA is designing, building and testing the entire flight system. The flight system will be integrated on the Express Logistics Carrier (ELC) on the International Space Station (ISS) after launch on the H-IIB Transfer Vehicle in 2012. This paper provides an overview of the technology research objectives, payload description, design challenges and pre-flight testing results.

  14. Development of flexible SAW sensors for non-destructive testing of structure

    Science.gov (United States)

    Takpara, R.; Duquennoy, M.; Courtois, C.; Gonon, M.; Ouaftouh, M.; Martic, G.; Rguiti, M.; Jenot, F.; Seronveaux, L.; Pelegris, C.

    2016-02-01

    In order to accurately examine structures surfaces, it is interesting to use surface SAW (Surface Acoustic Wave). Such waves are well suited for example to detect early emerging cracks or to test the quality of a coating. In addition, when coatings are thin or when emergent cracks are precocious, it is necessary to excite surface waves beyond 10MHz. Finally, when structures are not flat, it makes sense to have flexible or conformable sensors for their characterization. To address this problem, we propose to develop SAW type of interdigital sensors (or IDT for InterDigital Transducer), based on flexible piezoelectric plates. Initially, in order to optimize these sensors, we modeled the behavior of these sensors and identified the optimum characteristic sizes. In particular, the thickness of the piezoelectric plate and the width of the interdigital electrodes have been studied. Secondly, we made composites based on barium titanate foams in order to have flexible piezoelectric plates and to carry out thereafter sensors. Then, we studied several techniques in order to optimize the interdigitated electrodes deposition on this type of material. One of the difficulties concerns the fineness of these electrodes because the ratio between the length (typically several millimeters) and the width (a few tens of micrometers) of electrodes is very high. Finally, mechanical, electrical and acoustical characterizations of the sensors deposited on aluminum substrates were able to show the quality of our achievement.

  15. International Space Station Program Phase 3 Integrated Atmosphere Revitalization Subsystem Test

    Science.gov (United States)

    Perry, J. L.; Franks, G. D.; Knox, J. C.

    1997-01-01

    Testing of the International Space Station (ISS) U.S. Segment baseline configuration of the Atmosphere Revitalization Subsystem (ARS) by NASA's Marshall Space Flight Center (MSFC) was conducted as part of the Environmental Control and Life Support System (ECLSS) design and development program. This testing was designed to answer specific questions regarding the control and performance of the baseline ARS subassemblies in the ISS U.S. Segment configuration. These questions resulted from the continued maturation of the ISS ECLSS configuration and design requirement changes since 1992. The test used pressurized oxygen injection, a mass spectrometric major constituent analyzer, a Four-Bed Molecular Sieve Carbon Dioxide Removal Assembly, and a Trace Contaminant Control Subassembly to maintain the atmospheric composition in a sealed chamber at ISS specifications for 30 days. Human metabolic processes for a crew of four were simulated according to projected ISS mission time lines. The performance of a static feed water electrolysis Oxygen Generator Assembly was investigated during the test preparation phases; however, technical difficulties prevented its use during the integrated test. The Integrated ARS Test (IART) program built upon previous closed-door and open-door integrated testing conducted at MSFC between 1987 and 1992. It is the most advanced test of an integrated ARS conducted by NASA to demonstrate its end-to-end control and overall performance. IART test objectives, facility design, pretest analyses, test and control requirements, and test results are presented.

  16. Hydrogen depolarized carbon dioxide concentrator performance improvements and cell pair structural tests. [for manned space station

    Science.gov (United States)

    Huddleston, J. D.; Aylward, J. R.

    1973-01-01

    The investigations and testing associated with the CO2 removal efficiency and voltage degradation of a hydrogen depolarized carbon oxide concentrator are reported. Also discussed is the vibration testing of a water vapor electrolysis cell pair. Performance testing of various HDC cell pairs with Cs2CO3 electrolyte provided sufficient parametric and endurance data to size a six man space station prototype CO2 removal system as having 36 HDC cell pairs, and to verify a life capability exceeding six moths. Testing also demonstrated that tetramethylammonium carbonate is an acceptable HDC electrolyte for operating over the relative humidity range of 30 to 90 percent and over a temperature range of 50 to 80 F.

  17. Quantum Test of the Equivalence Principle and Space-Time aboard the International Space Station

    CERN Document Server

    Williams, Jason; Mueller, Holger; Yu, Nan

    2015-01-01

    We describe the Quantum Test of the Equivalence principle and Space Time (QTEST), a concept for an atom interferometry mission on the International Space Station (ISS). The primary science objective of the mission is a test of Einstein's equivalence principle with two rubidium isotope gases at a precision of better than 10$^{-15}$. Distinct from the classical tests is the use of quantum wave packets and their expected large spatial separation in the QTEST experiment. This dual species atom interferometer experiment will also be sensitive to time-dependent equivalence principle violations that would be signatures for ultralight dark-matter particles. In addition, QTEST will be able to perform photon recoil measurements to better than 10$^{-11}$ precision. This improves upon terrestrial experiments by a factor of 100, enabling an accurate test of the standard model of particle physics and contributing to mass measurement, in the proposed new international system of units (SI), with significantly improved precis...

  18. Test and evaluation of load converter topologies used in the Space Station Freedom power management and distribution dc test bed

    Science.gov (United States)

    Lebron, Ramon C.; Oliver, Angela C.; Bodi, Robert F.

    1991-01-01

    Power components hardware in support of the Space Station freedom dc Electric Power System were tested. One type of breadboard hardware tested is the dc Load Converter Unit, which constitutes the power interface between the electric power system and the actual load. These units are dc to dc converters that provide the final system regulation before power is delivered to the load. Three load converters were tested: a series resonant converter, a series inductor switch-mode converter, and a switching full-bridge forward converter. The topology, operation principles, and test results are described, in general. A comparative analysis of the three units is given with respect to efficiency, regulation, short circuit behavior (protection), and transient characteristics.

  19. Test and evaluation of load converter topologies used in the Space Station Freedom power management and distribution dc test bed

    Science.gov (United States)

    Lebron, Ramon C.; Oliver, Angela C.; Bodi, Robert F.

    1991-01-01

    Power components hardware in support of the Space Station freedom dc Electric Power System were tested. One type of breadboard hardware tested is the dc Load Converter Unit, which constitutes the power interface between the electric power system and the actual load. These units are dc to dc converters that provide the final system regulation before power is delivered to the load. Three load converters were tested: a series resonant converter, a series inductor switch-mode converter, and a switching full-bridge forward converter. The topology, operation principles, and test results are described, in general. A comparative analysis of the three units is given with respect to efficiency, regulation, short circuit behavior (protection), and transient characteristics.

  20. THE UNMANNED MISSION AVIONICS TEST HELICIOPTER – A FLEXIBLE AND VERSATILE VTOL-UAS EXPERIMENTAL SYSTEM

    Directory of Open Access Journals (Sweden)

    Dr. H.-W. Schulz

    2012-09-01

    Full Text Available civil customers. These applications cover a wide spectrum from R&D programs for the military customer to special services for the civil customer. This paper focuses on the technical conversion of a commercially available VTOL-UAS to ESG's Unmanned Mission Avionics Test Helicopter (UMAT, its concept and operational capabilities. At the end of the paper, the current integration of a radar sensor is described as an example of the UMATs flexibility. The radar sensor is developed by the Fraunhofer Institute for High Frequency Physics and Radar Techniques (FHR. It is integrated by ESG together with the industrial partner SWISS UAV.

  1. Numerical and Experimental Dynamic Analysis of IC Engine Test Beds Equipped with Highly Flexible Couplings

    Directory of Open Access Journals (Sweden)

    M. Cocconcelli

    2017-01-01

    Full Text Available Driveline components connected to internal combustion engines can be critically loaded by dynamic forces due to motion irregularity. In particular, flexible couplings used in engine test rig are usually subjected to high levels of torsional oscillations and time-varying torque. This could lead to premature failure of the test rig. In this work an effective methodology for the estimation of the dynamic behavior of highly flexible couplings in real operational conditions is presented in order to prevent unwanted halts. The methodology addresses a combination of numerical models and experimental measurements. In particular, two mathematical models of the engine test rig were developed: a torsional lumped-parameter model for the estimation of the torsional dynamic behavior in operative conditions and a finite element model for the estimation of the natural frequencies of the coupling. The experimental campaign addressed torsional vibration measurements in order to characterize the driveline dynamic behavior as well as validate the models. The measurements were achieved by a coder-based technique using optical sensors and zebra tapes. Eventually, the validated models were used to evaluate the effect of design modifications of the coupling elements in terms of natural frequencies (torsional and bending, torsional vibration amplitude, and power loss in the couplings.

  2. Remote Advanced Payload Test Rig (RAPTR) Portable Payload Test System for the International Space Station (ISS)

    Science.gov (United States)

    Calvert, John; Freas, George, II

    2017-01-01

    The RAPTR was developed to test ISS payloads for NASA. RAPTR is a simulation of the Command and Data Handling (C&DH) interfaces of the ISS (MIL-STD 1553B, Ethernet and TAXI) and is designed to facilitate rapid testing and deployment of payload experiments to the ISS. The ISS Program's goal is to reduce the amount of time it takes a payload developer to build, test and fly a payload, including payload software. The RAPTR meets this need with its user oriented, visually rich interface. Additionally, the Analog and Discrete (A&D) signals of the following payload types may be tested with RAPTR: (1) EXPRESS Sub Rack Payloads; (2) ELC payloads; (3) External Columbus payloads; (4) External Japanese Experiment Module (JEM) payloads. The automated payload configuration setup and payload data inspection infrastructure is found nowhere else in ISS payload test systems. Testing can be done with minimal human intervention and setup, as the RAPTR automatically monitors parameters in the data headers that are sent to, and come from the experiment under test.

  3. Remote Advanced Payload Test Rig (RAPTR) Portable Payload Test System for the International Space Station

    Science.gov (United States)

    De La Cruz, Melinda; Henderson, Steve

    2016-01-01

    The RAPTR was developed to test ISS payloads for NASA. RAPTR is a simulation of the Command and Data Handling (C&DH) interfaces of the ISS (MIL-STD1553B, Ethernet and TAXI) and is designed for rapid testing and deployment of payload experiments to the ISS. The ISS's goal is to reduce the amount of time it takes for a payload developer to build, test and fly a payload, including payload software. The RAPTR meets this need with its user oriented, visually rich interface.

  4. Test results on re-use of reclaimed shower water: Summary. [space stations

    Science.gov (United States)

    Verostko, C. E.; Garcia, R.; Sauer, R.; Linton, A. T.; Elms, T.; Reysa, R. P.

    1988-01-01

    A microgravity whole body shower (WBS) and waste water recovery systems (WWRS) were evaluated in three separate closed loop tests. Following a protocol similar to that anticipated for the U.S. Space Station, test subjects showered in a prototype whole body shower. The WWRS processes evaluated during the test series were phase change and reverse osmosis (RO). A preprototype Thermoelectric Integrated Hollow Fiber Membrane Evaporation Subsystem phase change process was used for the initial test with chemical pretreatment of the shower water waste input. The second and third tests concentrated on RO technologies. The second test evaluated a dynamic RO membrane consisting of zirconium oxide polyacrylic acid (ZOPA) membranes deposited on the interior diameter of 316L porous stainless steel tubes while the final test employed a thin semipermeable RO membrane deposited on the interior surface of polysulfone hollow fibers. All reclaimed water was post-treated for purity using ion exchange and granular activated carbon beds immediately followed by microbial control treatment using both heat and iodine. The test hardware, controls exercised for whole body showering, types of soaps evaluated, shower subject response to reclaimed water showering, and shower water collection and chemical pretreatment (if required) for microbial control are described. The WWRS recovered water performance and the effectiveness of the reclaimed water post-treatment techniques used for maintaining water purity and microorganism control are compared. Results on chemical and microbial impurity content of the water samples obtained from various locations in the shower water reuse system are summarized.

  5. Baghouse Slipstream Testing at TXU's Big Brown Station

    Energy Technology Data Exchange (ETDEWEB)

    John Pavlish; Jason Laumb; Robert Jensen; Jeffery Thompson; Christopher Martin; Mark Musich; Brandon Pavlish; Stanley Miller; Lucinda Hamre

    2007-04-30

    Performing sorbent testing for mercury control at a large scale is a very expensive endeavor and requires months of planning and careful execution. Even with good planning, there are plant limitations on what operating/design parameters can be varied/tested and when. For parameters that cannot be feasibly tested at the full scale (lower/higher gas flow, different bag material, cleaning methods, sorbents, etc.), an alternative approach is used to perform tests on a slipstream unit using flue gas from the plant. The advantage that a slipstream unit provides is the flexibility to test multiple operating and design parameters and other possible technology options without risking major disruption to the operation of the power plant. Additionally, the results generated are expected to simulate full-scale conditions closely, since the flue gas used during the tests comes directly from the plant in question. The Energy & Environmental Research Center developed and constructed a mobile baghouse that allows for cost-effective testing of impacts related to variation in operating and design parameters, as well as other possible mercury control options. Multiple sorbents, air-to-cloth ratios, bag materials, and cleaning frequencies were evaluated while flue gas was extracted from Big Brown when it fired a 70% Texas lignite-30% Powder River Basin (PRB) blend and a 100% PRB coal.

  6. Portable Automated Test Station: Using Engineering-Design Partnerships to Replace Obsolete Test Systems

    Science.gov (United States)

    2015-04-01

    assemblies are the PXI card cage, and the Power Board circuit card assembly (CCA). The Power Board provides all required PXI chassis power rails as well...be provided by the PATS-70A include: 1. PATS-70A System Calibration 2. PATS-70A System Self-Test 3. Digital Data Processing Unit (DDPU) 4. Dual Rail ...Adaptor (DRA) 5. DRA w/ Launcher Unit (LAU)105’s attached 6. Electronic Gun Control Unit (EGCU) 7. Electrical Test Panel (ETP) 8. LAU-105/A Guided

  7. Enhancing the performance of the T-peel test for thin and flexible adhered laminates

    Science.gov (United States)

    Padhye, Nikhil; Parks, David M.; Slocum, Alexander H.; Trout, Bernhardt L.

    2016-08-01

    Symmetrically bonded thin and flexible T-peel specimens, when tested on vertical travel machines, can be subject to significant gravitational loading, with the associated asymmetry and mixed-mode failure during peeling. This can cause erroneously high experimental peel forces to be recorded which leads to uncertainty in estimating interfacial fracture toughness and failure mode. To overcome these issues, a mechanical test fixture has been designed, for use with vertical test machines, that supports the unpeeled portion of the test specimen and suppresses parasitic loads due to gravity from affecting the peel test. The mechanism, driven by the test machine cross-head, moves at one-half of the velocity of the cross-head such that the unpeeled portion always lies in the plane of the instantaneous center of motion. Several specimens such as bonded polymeric films, laminates, and commercial tapes were tested with and without the fixture, and the importance of the proposed T-peel procedure has been demonstrated.

  8. Initial beam-profiling tests with the NML prototype station at the Fermilab A0 Photoinjector

    Energy Technology Data Exchange (ETDEWEB)

    Lumpkin, A.; Flora, R.; Johnson, A.S.; Ruan, J.; Santucci, J.; Scarpine, V.; Sun, Y.-E.; Thurman-Keup, R.; Church, M.; Wendt, M.; /Fermilab

    2011-03-01

    The beam-profile diagnostics station prototype for the superconducting rf electron linac being constructed at Fermilab at the New Muon Lab has been tested. The station uses intercepting radiation converter screens for the low-power beam mode: either a 100-{micro}m thick YAG:Ce single crystal scintillator or a 1-{micro}m thin Al optical transition radiation (OTR) foil. The screens are oriented with the surface perpendicular to the beam direction. A downstream mirror with its surface at 45 degrees to the beam direction is used to direct the radiation into the optical transport. The optical system has better than 20 (10) {micro}m rms spatial resolution when covering a vertical field of view of 18 (5) mm. The initial tests were performed at the A0 Photoinjector at a beam energy of {approx}15 MeV and with micropulse charges from 25 to 500 pC for beam sizes of 45 to 250 microns. Example results will be presented.

  9. Initial beam-profiling tests with the NML prototype station at the Fermilab A0 Photoinjector

    CERN Document Server

    Lumpkin, A; Johnson, A S; Ruan, J; Santucci, J; Scarpine, V; Sun, Y -E; Thurman-Keup, R; Church, M; Wendt, M

    2012-01-01

    The beam-profile diagnostics station prototype for the superconducting rf electron linac being constructed at Fermilab at the New Muon Lab has been tested. The station uses intercepting radiation converter screens for the low-power beam mode: either a 100-\\mu m thick YAG:Ce single crystal scintillator or a 1-\\mu m thin Al optical transition radiation (OTR) foil. The screens are oriented with the surface perpendicular to the beam direction. A downstream mirror with its surface at 45 degrees to the beam direction is used to direct the radiation into the optical transport. The optical system has better than 20 (10) \\mu m rms spatial resolution when covering a vertical field of view of 18 (5) mm. The initial tests were performed at the A0 Photoinjector at a beam energy of ~15 MeV and with micropulse charges from 25 to 500 pC for beam sizes of 45 to 250 microns. Example results will be presented.

  10. Test Station for Magnetization Measurements on Large Quantities of Superconducting Strands

    CERN Document Server

    Le Naour, S; Billan, J; Genest, J

    2001-01-01

    In the superconducting main magnets of the Large Hadron Collider (LHC), persistent currents in the superconductor determine the field quality at injection field. For this reason it is necessary to check the magnetization of the cable strands during their production. During four years, this requires measurements of the width of the strand magnetization hysteresis loop at 0.5 T, 1.9 K, at a rate of up to eight samples per day. This paper describes the design, construction and the first results of a magnetization test station built for this purpose. The samples are cooled in a cryostat, with a 2-m long elliptic tail. This tail is inserted in a normal conducting dipole magnet with a field between ± 1.5 T. Racetrack pick-up coils, integrated in the cryostat, detect the voltage due to flux change, which is then integrated numerically. The sample holder can contain eight strand samples, each 20 cm long. The test station operates in two modes: either the sample is fixed while the external field is changed, or the sa...

  11. Biological induced corrosion of materials II: New test methods and experiences from mir station

    Science.gov (United States)

    Klintworth, R.; Reher, H. J.; Viktorov, A. N.; Bohle, D.

    1999-09-01

    During previous long-term manned missions, more than 100 species of microorganisms have been identified on surfaces of materials (bacteria and fungi). Among them were potentially pathogenic ones (saprophytes) which are capable of active growth on artificial substrates, as well as technophilic bacteria and fungi causing damages (destruction and degradation) to various materials (metals and polymers), resulting in failures and disruptions in the functioning of equipment and hardware. Aboard a space vehicle some microclimatic parameters are optimal for microorganism growth: the atmospheric fluid condensate with its specific composition, chemical and/or antropogenic contaminants (human metobolic products, etc.) all are stimulating factors for the development of bacteria and mould fungi on materials of the interior and equipment of an orbital station during its operational phase(s). Especially Russian long-term missions (SALJUT, MIR) have demonstrated that uncontrolled interactions of microorganisms with materials will ultimately lead to the appearence of technological and medical risks, significantly influencing safety and reliability characteristics of individual as well as whole systems and/ or subsystems. For a first conclusion, it could be summarized, that countermeasures and anti-strategies focussing on Microbial Contamination Management (MCM) for the International Space Station (ISS, next long-term manned mission) at least require a new materials test approach. Our respective concept includes a combined age-ing/biocorrosion test sequence. It is represented here, as well as current status of MCM program, e.g. continuous monitoring (microbiological analyses), long-term disinfection, frequent cleaning methods, mathematical modeling of ISS, etc.

  12. Standard test method for determination of surface lubrication on flexible webs

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method has been used since 1988 as an ANSI/ISO standard test for determination of lubrication on processed photographic films. Its purpose was to determine the presence of process-surviving lubricants on photographic films. It is the purpose of this test method to expand the applicability of this test method to other flexible webs that may need lubrication for suitable performance. This test measures the breakaway (static) coefficient of friction of a metal rider on the web by the inclined plane method. The objectives of the test is to determine if a web surface has a lubricant present or not. It is not intended to assign a friction coefficient to a material. It is not intended to rank lubricants. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish ...

  13. On Dimensions of OTA Setups for Massive MIMO Base Stations Radiated Testing

    DEFF Research Database (Denmark)

    Kyösti, Pekka; Fan, Wei; Pedersen, Gert F.

    2016-01-01

    The development of base stations (BS) with large aperture antenna arrays, enabled partially by the utilization of cmWave and mmWave frequency bands, will require radiated testing in fading conditions. In this paper, the objective is to investigate the suitable measurement distances and physical...... (DoA) estimation algorithm as well as multi-user MIMO sum-rate capacity are investigated to determine the range of the test setup. It was found that the link budget doesn’t support for the measurement distances claimed by the Fraunhofer distance. Most of the utilized metrics, especially the sum rate...... capacity, indicate that smaller setup sizes can still yield reasonable measurement accuracy. Simulations were performed at 2.6, 3.5, and 28 GHz frequencies....

  14. Integrated water management system - Description and test results. [for Space Station waste water processing

    Science.gov (United States)

    Elden, N. C.; Winkler, H. E.; Price, D. F.; Reysa, R. P.

    1983-01-01

    Water recovery subsystems are being tested at the NASA Lyndon B. Johnson Space Center for Space Station use to process waste water generated from urine and wash water collection facilities. These subsystems are being integrated into a water management system that will incorporate wash water and urine processing through the use of hyperfiltration and vapor compression distillation subsystems. Other hardware in the water management system includes a whole body shower, a clothes washing facility, a urine collection and pretreatment unit, a recovered water post-treatment system, and a water quality monitor. This paper describes the integrated test configuration, pertinent performance data, and feasibility and design compatibility conclusions of the integrated water management system.

  15. Integrated water management system - Description and test results. [for Space Station waste water processing

    Science.gov (United States)

    Elden, N. C.; Winkler, H. E.; Price, D. F.; Reysa, R. P.

    1983-01-01

    Water recovery subsystems are being tested at the NASA Lyndon B. Johnson Space Center for Space Station use to process waste water generated from urine and wash water collection facilities. These subsystems are being integrated into a water management system that will incorporate wash water and urine processing through the use of hyperfiltration and vapor compression distillation subsystems. Other hardware in the water management system includes a whole body shower, a clothes washing facility, a urine collection and pretreatment unit, a recovered water post-treatment system, and a water quality monitor. This paper describes the integrated test configuration, pertinent performance data, and feasibility and design compatibility conclusions of the integrated water management system.

  16. Mast material test program (MAMATEP). [for Solar Array Assembly of Space Station Photovoltaic Power Module

    Science.gov (United States)

    Ciancone, Michael L.; Rutledge, Sharon K.

    1988-01-01

    The MAMATEP program, which is aimed at verifying the need for and evaluating the performance of various protection techniques for the solar array assembly mast of the Space Station photovoltaic power module, is discussed. Coated and uncoated mast material samples have been environmentally tested and evaluated, before and after testing, in terms of mass and bending modulus. The protective coatings include CV-1144 silicone, a Ni/Al/InSn eutectic, and an open-weave Al braid. Long-term plasma asher results from unprotected samples indicate that, even though fiberglass-epoxy samples degrade, a protection technique may not be necessary to ensure structural integrity. A protection technique, however, may be desirable to limit or contain the amount of debris generated by the degradation of the fiberglass-epoxy.

  17. Multiple Hollow Cathode Wear Testing for the Space Station Plasma Contactor

    Science.gov (United States)

    Soulas, George C.

    1994-01-01

    A wear test of four hollow cathodes was conducted to resolve issues associated with the Space Station plasma contactor. The objectives of this test were to evaluate unit-to-unit dispersions, verify the transportability of contamination control protocols developed by the project, and to evaluate cathode contamination control and activation procedures to enable simplification of the gas feed system and heater power processor. These objectives were achieved by wear testing four cathodes concurrently to 2000 hours. Test results showed maximum unit-to-unit deviations for discharge voltages and cathode tip temperatures to be +/-3 percent and +/-2 percent, respectively, of the nominal values. Cathodes utilizing contamination control procedures known to increase cathode lifetime showed no trends in their monitored parameters that would indicate a possible failure, demonstrating that contamination control procedures had been successfully transferred. Comparisons of cathodes utilizing and not utilizing a purifier or simplified activation procedure showed similar behavior during wear testing and pre- and post-test performance characterizations. This behavior indicates that use of simplified cathode systems and procedures is consistent with long cathode lifetimes.

  18. Test and Evaluation Station (TESt) - A Control System for the ALICE-HMPID Liquid Distribution Prototype

    CERN Document Server

    Maatta, E; CERN. Geneva; Swoboda, Detlef; Lecoeur, G

    1999-01-01

    The sub-detectors and systems in the ALICE experiment [1] are of various types. However, during physics runs, all devices necessary for the operation of the detector must be accessible and controllable through a common computer interface. Throughout all other periods each sub-detector requires maintenance, upgrading or test operation. To this end, an access independant of other sub-detectors must be guaranteed. These basic requirements impose a fair number of constraints on the architecture and components of the Detector Control System (DCS). The purpose of the TESt project consisted in the construction of a stand alone unit for a specific sub-system of an ALICE detector in order to gain first experience with commercial products for detector control. Although the control system includes only a small number of devices and is designed for a particular application, it covers nevertheless all layers of a complete system and can be extended or used in different applications. The control system prototype has been...

  19. Gravimetry and GPS observations at Belgrano II station to test ocean tidal models

    Directory of Open Access Journals (Sweden)

    M. Scheinert

    2007-12-01

    Full Text Available In the framework of a joint Argentine-German project gravimetric time series observations are being carried out at the Argentine Antarctic station Belgrano II. Two gravity meters were installed in the first half of February 2007. The set-up of the gravimeters as well as first results of the ongoing observations are discussed. Additionally, kinematic positions derived from a GPS-station at the Vahsel Bay glacier near Belgrano II can be used to get a first insight into the floating behavior of this glacier. The goal of these observations is to discriminate the effect of ocean tides and to test ocean tidal models. Since ocean tides are an important phenomenon that has to be considered in a variety of geoscientific investigations in polar regions, appropriate corrections have to be applied in the different analyses, e.g. to infer temporal mass variations from satellite data, to investigate ice-shelf dynamics and deformations, or to come up with precise station positions and velocities within a terrestrial reference system. However, the ocean tide models show larger uncertainties in the Antarctic seas and (moreover at areas covered by ice shelves and, therefore, need to be improved. This joint Argentine-German project is a contribution to the International Polar Year 2007/2008 and its project POLENET. After completion of the recordings at Belgrano II by the end of 2007 it is planned to move the equipment to San Mart ín in order to get a second gravimetric time series during the year 2008.

  20. An assessment of wind tunnel test data on flexible thermal protection materials and results of new fatigue tests of threads

    Science.gov (United States)

    Coe, Charles F.

    1985-01-01

    Advanced Flexible Reusable Surface Insulation (AFRSI) was developed as a replacement for the low-temperature (white) tiles on the Space Shuttle. The first use of the AFRSI for an Orbiter flight was on the OMS POD of Orbiter (OV-099) for STS-6. Post flight examination after STS-6 showed that damage had occurred to the AFRSI during flight. The failure anomaly between previous wind-tunnel tests and STS-6 prompted a series of additional wind tunnel tests to gain an insight as to the cause of the failure. An assessment of all the past STS-6 wind tunnel tests pointed out the sensitivity of the test results to scaling of dynamic loads due to the difference of boundary layer thickness, and the material properties as a result of exposure to heating. The thread component of the AFRSI was exposed to fatigue testing using an apparatus that applied pulsating aerodynamic loads on the threads similar to the loads caused by an oscillating shock. Comparison of the mean values of the number-of-cycles to failure showed that the history of the thread was the major factor in its performance. The thread and the wind tunnel data suggests a mechanism of failure for the AFRSI.

  1. Modified calibration protocol evaluated in a model-based testing of SBR flexibility

    DEFF Research Database (Denmark)

    Corominas, Lluís; Sin, Gürkan; Puig, Sebastià;

    2011-01-01

    operation using fixed phase length and dissolved oxygen set points and two real-time control strategies is compared to find optimal operation under dynamic conditions. The results show that a validated model of high quality is obtained using the updated protocol and that the optimization of the system......The purpose of this paper is to refine the BIOMATH calibration protocol for SBR systems, in particular to develop a pragmatic calibration protocol that takes advantage of SBR information-rich data, defines a simulation strategy to obtain proper initial conditions for model calibration and provides...... statistical evaluation of the calibration outcome. The updated calibration protocol is then evaluated on a case study to obtain a thoroughly validated model for testing the flexibility of an N-removing SBR to adapt the operating conditions to the changing influent wastewater load. The performance of reference...

  2. Modified calibration protocol evaluated in a model-based testing of SBR flexibility.

    Science.gov (United States)

    Corominas, Lluís; Sin, Gürkan; Puig, Sebastià; Balaguer, Maria Dolors; Vanrolleghem, Peter A; Colprim, Jesús

    2011-02-01

    The purpose of this paper is to refine the BIOMATH calibration protocol for SBR systems, in particular to develop a pragmatic calibration protocol that takes advantage of SBR information-rich data, defines a simulation strategy to obtain proper initial conditions for model calibration and provides statistical evaluation of the calibration outcome. The updated calibration protocol is then evaluated on a case study to obtain a thoroughly validated model for testing the flexibility of an N-removing SBR to adapt the operating conditions to the changing influent wastewater load. The performance of reference operation using fixed phase length and dissolved oxygen set points and two real-time control strategies is compared to find optimal operation under dynamic conditions. The results show that a validated model of high quality is obtained using the updated protocol and that the optimization of the system's performance can be achieved in different manners by implementing the proposed control strategies.

  3. In vitro axial preload application during spine flexibility testing: towards reduced apparatus-related artefacts.

    Science.gov (United States)

    Cripton, P A; Bruehlmann, S B; Orr, T E; Oxland, T R; Nolte, L P

    2000-12-01

    Presently, there is little consensus about how, or even if, axial preload should be incorporated in spine flexibility tests in order to simulate the compressive loads naturally present in vivo. Some preload application methods are suspected of producing unwanted "artefact" forces as the specimen rotates and, in doing so, influencing the resulting kinematics. The objective of this study was to quantitatively compare four distinct types of preload which have roots in contemporary experimental practice. The specific quantities compared were the reaction moments and forces resulting at the intervertebral disc and specimen kinematics. The preload types incorporated increasing amounts of caudal constraint on the preload application vector ranging from an unconstrained dead-load arrangement to an apparatus that allowed the vector to follow rotations of the specimen. Six human cadaveric spine segments were tested (1-L1/L2, 3-L2/L3, 1-L3/L4 and 1-L4/L5). Pure moments were applied to the specimens with each of the four different types of compressive preload. Kinematic response was measured using an opto-electronic motion analysis system. A six-axis load cell was used to measure reaction forces and moments. Artefact reaction moments and shear forces were significantly affected by preload application method and magnitude. Unconstrained preload methods produced high artefact moments and low artefact shear forces while more constrained methods did the opposite. A mechanical trade-off is suggested by our results, whereby unwanted moment can only be prevented at the cost of shear force production. When comparing spine flexibility studies, caution should be exercised to ensure preload was applied in a similar manner for all studies. Unwanted moments or forces induced as a result of preload application method may render the comparison of two seemingly similar studies inappropriate.

  4. Data Acquisition System Architecture and Capabilities at NASA GRC Plum Brook Station's Space Environment Test Facilities

    Science.gov (United States)

    Evans, Richard K.; Hill, Gerald M.

    2014-01-01

    Very large space environment test facilities present unique engineering challenges in the design of facility data systems. Data systems of this scale must be versatile enough to meet the wide range of data acquisition and measurement requirements from a diverse set of customers and test programs, but also must minimize design changes to maintain reliability and serviceability. This paper presents an overview of the common architecture and capabilities of the facility data acquisition systems available at two of the world's largest space environment test facilities located at the NASA Glenn Research Center's Plum Brook Station in Sandusky, Ohio; namely, the Space Propulsion Research Facility (commonly known as the B-2 facility) and the Space Power Facility (SPF). The common architecture of the data systems is presented along with details on system scalability and efficient measurement systems analysis and verification. The architecture highlights a modular design, which utilizes fully-remotely managed components, enabling the data systems to be highly configurable and support multiple test locations with a wide-range of measurement types and very large system channel counts.

  5. The network architecture and site test of DCIS in Lungmen nuclear power station

    Energy Technology Data Exchange (ETDEWEB)

    Lee, C. K. [Instrument and Control Section, Lungmen Nuclear Power Station, Taiwan Power Company, Taipei County Taiwan (China)

    2006-07-01

    The Lungmen Nuclear Power Station (LMNPS) is located in North-Eastern Seashore of Taiwan. LMNPP has two units. Each unit generates 1350 Megawatts. It is the first ABWR Plant in Taiwan and is under-construction now. Due to contractual arrangement, there are seven large I and C suppliers/designers, which are GE NUMAC, DRS, Invensys, GEIS, Hitachi, MHI, and Stone and Webster company. The Distributed Control and Information System (DCIS) in Lungmen are fully integrated with the state-of-the-art computer and network technology. General Electric is the leading designer for integration of DCIS. This paper presents Network Architecture and the Site Test of DCIS. The network architectures are follows. GE NUMAC System adopts the point to point architecture, DRS System adopts Ring type architecture with SCRAMNET protocol, Inevnsys system adopts IGiga Byte Backbone mesh network with Rapid Spanning Tree Protocol, GEIS adopts Ethernet network with EGD protocol, Hitachi adopts ring type network with proprietary protocol. MHI adopt Ethernet network with UDP. The data-links are used for connection between different suppliers. The DCIS architecture supports the plant automation, the alarm prioritization and alarm suppression, and uniform MMI screen for entire plant. The Test Program regarding the integration of different network architectures and Initial DCIS architecture Setup for 161KV Energization will be discussed. Test tool for improving site test schedule, and lessons learned from FAT will be discussed too. And conclusions are at the end of this paper. (authors)

  6. The SOS-LUX-TOXICITY-Test on the International Space Station.

    Science.gov (United States)

    Rabbow, Elke; Stojicic, Nevena; Walrafen, David; Baumstark-Khan, Christa; Rettberg, Petra; Schulze-Varnholt, Dirk; Franz, Markus; Reitz, Günther

    2006-01-01

    For the safety of astronauts and to ensure the stability and integrity of the genome of microorganisms and plants used in bioregenerative life support systems, it is important to improve our knowledge of the combined action of (space) radiation and microgravity. The SOS-LUX-TOXICITY test, as part of the TRIPLE-LUX project (accepted for flight at Biolab in Columbus on the International Space Station, (ISS)), will provide an estimation of the health risk resulting from exposure of astronauts to the radiation environment of space in microgravity. The project will: (i) increase our knowledge of biological/health threatening action of space radiation and enzymatic DNA repair; (ii) uncover cellular mechanisms of synergistic interaction of microgravity and space radiation; (iii) provide specified biosensors for spacecraft milieu examination; and (iv) provide experimental data on stability and integrity of bacterial DNA in spacecrafts. In the bacterial biosensor "SOS-LUX-Test" developed at DLR (patent), bacteria are transformed with the pBR322-derived plasmid pPLS-1 or the similar, advanced plasmid SWITCH, both carrying the promoterless lux operon of Photobacterium leiognathi as the reporter element controlled by a DNA damage-dependent SOS promoter as sensor element. A short description of the space experiment is given, and the current status of adaptation of the SOS-LUX-Test to the ISS, i.e. first results of sterilization, biocompatibility and functional tests performed with the already available hardware and bread board model of the automated space hardware under development, is described here.

  7. SiPM application for a detector for UHE neutrinos tested at Sphinx station

    Energy Technology Data Exchange (ETDEWEB)

    Iori, M. [Sapienza University of Rome, Piazzale A. Moro 5, 00185 Rome (Italy); Atakisi, I.O. [University of Kafkas, 36100 Kars (Turkey); Chiodi, G. [INFN, Sezione Roma 1, Piazzale A. Moro 2, 00185 Rome (Italy); Denizli, H. [Abant Izzet Baysal University, 14280 Bolu (Turkey); Ferrarotto, F. [INFN, Sezione Roma 1, Piazzale A. Moro 2, 00185 Rome (Italy); Kaya, M. [University of Kafkas, 36100 Kars (Turkey); Yilmaz, A. [Abant Izzet Baysal University, 14280 Bolu (Turkey); Recchia, L. [INFN, Sezione Roma 1, Piazzale A. Moro 2, 00185 Rome (Italy); Russ, J. [Carnegie-Mellon University, Pittsburgh, PA 15213 (United States)

    2014-04-01

    We present the preliminary test results of the prototype detector, working at Sphinx Observatory Center, Jungfraujoch (∼3800 m a.s.l.) HFSJG – Switzerland. This prototype detector is designed to measure large zenith angle showers produced by high energy neutrino interactions in the Earth crust. This station provides us an opportunity to understand if the prototype detector works safely (or not) under hard environmental conditions (the air temperature changes between −25 °C and −5 °C). The detector prototype is using silicon photomultiplier (SiPM) produced by SensL and DRS4 chip as read-out part. Measurements at different temperature at fixed bias voltage (∼29.5 V) were performed to reconstruct tracks by Time Of Flight.

  8. Assessing Measurement Distances for OTA Testing of Massive MIMO Base Station at 28 GHz

    DEFF Research Database (Denmark)

    Kyösti, Pekka; Fan, Wei; Kyrolainen, Jukka

    2017-01-01

    This paper discusses physical dimensions for a multi probe anechoic chamber based (MPAC) over-the-air (OTA) setup aiming for base station (BS) testing. The target frequency of the simulated massive multiple-input-multiple-output (MIMO) BS arrays is 28 GHz. The assessment is performed with two...... metrics. The first metric is a new power metric based on assumptions of a code book of fixed beams and planar waves. The second one is the multi-user (MU) MIMO sum rate capacity. The intention is to evaluate physical dimensions in metres with respect to different BS array sizes. Simulation results...... indicate that OTA performance of a BS array with maximum dimension of 0.15m could be measured with a setup having measurement distance of approximately 1m...

  9. The association between disease and profitability in individual finishing boars at a test station

    DEFF Research Database (Denmark)

    Jensen, Tina Birk; Baadsgaard, Niels Peter; Houe, Hans

    2008-01-01

    Endemic diseases in finisher herds are considered to be costly for the pig producer. We investigated the effect of diseases on the profit margin using data from a Danish boar test station (n = 5777) collected from July 2002 to December 2004. Boars reaching a target slaughter weight of at least 80......: profit margin. The results showed that treatment in the finishing period had a negative effect on the profit margin. According to the least square means estimates, boars that were treated parenterally had a reduction in the profit margin of 2.24 €. This corresponded to a reduction in the profit margin...... of 17%. Boars treated orally had a reduction of 0.88 €, which corresponded to a reduction in the profit margin of 7%. Pathological findings, breed and weight at 4 weeks were also significantly associated with the profit margin. The effect of pathological findings was influenced by breed and caused...

  10. Forgiveness Flexibility

    Directory of Open Access Journals (Sweden)

    Tuğba Seda Çolak

    2016-01-01

    Full Text Available Forgiveness flexibility is the skill to minimize the negative effect of an event by using cognitive, affective and behavioral skills while taking a stand at the end of an injurious process. A number of studies were conducted to test the flexibility of the structure of forgiveness. The theoretical structure, structural validity and the confirmatory factor analysis supported the theoretical structure of forgiveness flexibility. The criterion validity evaluated in similar manners was found high. Forgiveness flexibility designed as a three dimensional structure and its sub-dimensions was confirmed theoretically as the recognition of forgivenessand the internalization of forgiveness through insight and its practice.

  11. The SOS-LUX-LAC-FLUORO-Toxicity-test on the International Space Station (ISS)

    Science.gov (United States)

    Rabbow, E.; Rettberg, P.; Baumstark-Khan, C.; Horneck, G.

    In the 21 st century, an increasing number of astronauts will visit the International Space Station (ISS) for prolonged times. Therefore it is of utmost importance to provide necessary basic knowledge concerning risks to their health and their ability to work on the station and during extravehicular activities (EVA) in free space. It is the aim of one experiment of the German project TRIPLE-LUX (to be flown on the ISS) to provide an estimation of health risk resulting from exposure of the astronauts to the radiation in space inside the station as well as during extravehicular activities on one hand, and of exposure of astronauts to unavoidable or as yet unknown ISS-environmental genotoxic substances on the other. The project will (i) provide increased knowledge of the biological action of space radiation and enzymatic repair of DNA damage, (ii) uncover cellular mechanisms of synergistic interaction of microgravity and space radiation and (iii) examine the space craft milieu with highly specific biosensors. For these investigations, the bacterial biosensor SOS-LUX-LAC-FLUORO-Toxicity-test will be used, combining the SOS-LUX-Test invented at DLR Germany (Patent) with the commercially available LAC-FLUORO-Test. The SOS-LUX-Test comprises genetically modified bacteria transformed with the pBR322-derived plasmid pPLS-1. This plasmid carries the promoterless lux operon of Photobacterium leiognathi as a reporter element under control of the DNA-damage dependent SOS promoter of ColD as sensor element. This system reacts to radiation and other agents that induce DNA damages with a dose dependent measurable emission of bioluminescence of the transformed bacteria. The analogous LAC-FLUORO-Test has been developed for the detection of cellular responses to cytotoxins. It is based on the constitutive expression of green fluorescent protein (GFP) mediated by the bacterial protein expression vector pGFPuv (Clontech, Palo Alto, USA). In response to cytotoxic agents, this system

  12. Flexible Electronics Research Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Flexible Electronics Research Facility designs, synthesizes, tests, and fabricates materials and devices compatible with flexible substrates for Army information...

  13. Ultrasonic non-destructive testing of pieces of complex geometry with a flexible phased array transducer

    Science.gov (United States)

    Chatillon; Cattiaux; Serre; Roy

    2000-03-01

    Ultrasonic non-destructive testing of components of complex geometry in the nuclear industry faces several difficulties: sensitivity variations due to unmatched contact, inaccurate localization of defects due to variations of transducer orientation, and uncovered area of the component. To improve the performances of such testing and defect characterization, we propose a new concept of ultrasonic contact phased array transducer. The phased array transducer has a flexible radiating surface able to fit the actual surface of the piece to optimize the contact and thus the sensitivity of the test. To control the transmitted field, and therefore to improve the defect characterization, a delay law optimizing algorithm is developed. To assess the capability of such a transducer, the Champ-Sons model, developed at the French Atomic Energy Commission for predicting field radiated by arbitrary transducers into pieces, has to be extended to sources directly in contact with pieces of complex geometry. The good behavior of this new type of probe predicted by computations is experimentally validated with a jointed transducer positioned on pieces of various profiles.

  14. Full-scale testing of pipework systems and flexible risers subject to noise and vibration

    Energy Technology Data Exchange (ETDEWEB)

    Every, M.J.; Goyder, G.D.; Jee, T.; Swindell, R.

    2005-07-01

    The occurrence of potentially damaging noise and vibration levels in pipework has required the development of a full-scale testing facility. This facility can expose pipework to high static pressures and flow and can generate the large dynamic pressures that constitute noise. A consortium was formed that assembled the various specialist knowledge needed for the test facility. The outcome of the test work enables production flow through a flexible riser system throughout a range of flow rates and most significantly to be substantially increased. The benefits are an increased profitability of the asset, greater confidence in fatigue life prediction and an improved understanding for use in design. Flexible risers are increasingly being used offshore and most recently for the export of dry gas. This has given rise to the phenomenon of the 'singing riser', which generates sufficiently large noise levels to cause fatigue damage to the riser system. This phenomenon is currently limiting production rates offshore. As gas flows within the riser it passes over internal corrugation, which gives rise to vortex shedding from corrugated edges. The frequency of the vortex shedding is described by the Strouhal relationship so that it depends upon the flow velocity and the riser geometry. It appears from measurements on several offshore risers that this is fairly constant for a range of export pressures and flow rates. The shedding of the vortices is not necessarily correlated along the length of the riser. However, if there is small-bore pipework attached to the riser system which has a similar acoustic frequency to the Strouhal frequency then 'lock-on' can occur which may cause full correlation of vortex shedding. The lock-on mechanism is not totally understood but when the small-bore pipework's acoustic frequency is excited it provides a positive feed back to enhance the vortex shedding within the riser. The consequence is that the shedding within the

  15. Microbiological Tests Performed During the Design of the International Space Station ECLSS: Part 1, Bulk Phase Water and Wastewater

    Science.gov (United States)

    Roman, Monsi C.; Mittelman, Marc W.

    2010-01-01

    This slide presentation summarizes the studies performed to assess the bulk phase microbial community during the Space Station Water Recover Tests (WRT) from 1990-1998. These tests show that it is possible to recycle water from different sources including urine, and produce water that can exceed the quality of municpally produced tap water.

  16. Effect of High-Humidity Testing on Material Parameters of Flexible Printed Circuit Board Materials

    Science.gov (United States)

    Lahokallio, Sanna; Saarinen, Kirsi; Frisk, Laura

    2013-09-01

    The tendency of polymers to absorb moisture impairs especially their electrical and mechanical properties. These are important characteristics for printed circuit board (PCB) materials, which should provide mechanical support as well as electrical insulation in many different environments in order to guarantee safe operation for electrical devices. Moreover, the effects of moisture are accelerated at increased temperatures. In this study, three flexible PCB dielectric materials, namely polyimide (PI), fluorinated ethylene-propylene (FEP), and polyethylene terephthalate (PET), were aged over different periods of time in a high-humidity test, in which the temperature was 85°C and relative humidity 85%. After aging, the changes in the structure of the polymers were studied by determining different material parameters such as modulus of elasticity, glass-transition temperature, melting point, coefficient of thermal expansion, water absorption, and crystallinity, and changes in the chemical structure with several techniques including thermomechanical analysis, differential scanning calorimetry, Fourier-transform infrared spectroscopy, moisture analysis, and a precision scale. The results showed that PI was extremely stable under the aging conditions and therefore an excellent choice for electrical applications under harsh conditions. Similarly, FEP proved to be relatively stable under the applied aging conditions. However, its crystallinity increased markedly during aging, and after 6000 h of aging the results indicated oxidation. PET suffered from hydrolysis during the test, leading to its embrittlement after 2000 h of aging.

  17. Addressing Challenges to the Design & Test of Operational Lighting Environments for the International Space Station

    Science.gov (United States)

    Clark, Toni A.

    2014-01-01

    In our day to day lives, the availability of light, with which to see our environment, is often taken for granted. The designers of land based lighting systems use sunlight and artificial light as their toolset. The availability of power, quantity of light sources, and variety of design options are often unlimited. The accessibility of most land based lighting systems makes it easy for the architect and engineer to verify and validate their design ideas. Failures with an implementation, while sometimes costly, can easily be addressed by renovation. Consider now, an architectural facility orbiting in space, 260 miles above the surface of the earth. This human rated architectural facility, the International Space Station (ISS) must maintain operations every day, including life support and appropriate human comforts without fail. The facility must also handle logistics of regular shipments of cargo, including new passengers. The ISS requires accommodations necessary for human control of machine systems. Additionally, the ISS is a research facility and supports investigations performed inside and outside its livable volume. Finally, the facility must support remote operations and observations by ground controllers. All of these architectural needs require a functional, safe, and even an aesthetic lighting environment. At Johnson Space Center, our Habitability and Human Factors team assists our diverse customers with their lighting environment challenges, via physical test and computer based analysis. Because of the complexity of ISS operational environment, our team has learned and developed processes that help ISS operate safely. Because of the dynamic exterior lighting environment, uses computational modeling to predict the lighting environment. The ISS' orbit exposes it to a sunrise every 90 minutes, causing work surfaces to quickly change from direct sunlight to earthshine to total darkness. Proper planning of vehicle approaches, robotics operations, and crewed

  18. Evaluation of the field tests of flexibility of the lower extremity: reliability and the concurrent and factorial validity.

    Science.gov (United States)

    Bozic, Predrag R; Pazin, Nemanja R; Berjan, Bobana B; Planic, Nenad M; Cuk, Ivan D

    2010-09-01

    The purpose of this study was to evaluate the standard field tests of flexibility of the lower extremity through their (a) intratrial and test-retest reliability, (b) concurrent validity with respect to a high-precision 3D system for kinematic recording, and (c) factorial validity. Physically active men (n = 84) were tested over 2 separate sessions by means of standard simple devices (kinanthropometry, ruler, and protractor) on the following flexibility tests: leg raise in a supine position, hip abduction test, single-legged knee bend (SLKB), sideward leg splits (SdLS), sit and reach (SR), sideways leg splits, and lengthwise leg splits. Additionally, 17 participants were simultaneously tested by means of a laboratory 3D kinematic analysis system. Most of the tests demonstrated high intratrial and test-retest reliability and concurrent validity. The exceptions were SLKB and SR tests that revealed not only a somewhat lower reliability but also a lower concurrent validity. For estimation of factorial validity, we applied a principal component analysis of the intercorrelations among the evaluated flexibility tests that revealed a single extracted principal component. Strong mutual relationships among them also suggest that very few of them, if not a single one, should be applied within the standard batteries of physical performance tests. We particularly recommend using SdLS over the most frequently used SR not only because of its relatively high reliability and validity but also because of its postural properties. Finally, we conclude that most of the standard field tests of flexibility of the lower extremity based on using inexpensive field equipment could be both reliable and valid and, therefore, justified for use in routine testing.

  19. Application of an AM-BLUP to the station test results of Italian Saddle horse stallions

    Directory of Open Access Journals (Sweden)

    C. Pieramati

    2010-04-01

    Full Text Available The data collected in the first seven years of the 100-day Station Test for Italian Saddle Horse stallions have been used to estimate EBVs by single trait - repeatability AM-BLUP. There were 9449 scores for “character” and “gaits”, and 3564 for “jumping ability” in the training period; 344 scores for each trait were also available from the final evaluations assigned by two well-known professional riders; in the pedigree file of the 180 tested horses there were 2837 animals. Heritability estimates were .38±.02 and .23±.14 for “character”, .60±.02 and .58±.04 for “gaits”, and .48±.02 and .52±.04 for “jumping”, in the training period and in the final evaluation, respectively. The training period and the final evaluation were weighted 90% and 10% in each trait index, and the weights for “character”, “gaits” and “jumping” were 25%, 25% and 50% in the overall index. The genetic index was correlated .97 with the current official index, both linearly and in rank: therefore, the 82 licensed stallions give a selection intensity of .85, instead of the theoretical maximum of .87. Although the difference in the response to selection that the switching to BLUP could assure is low, the breeders could make comparisons between stallions approved in different editions.

  20. Nickel-Hydrogen Battery Cell Life Test Program Update for the International Space Station

    Science.gov (United States)

    Miller, Thomas B.

    2000-01-01

    NASA and Boeing North America are responsible for constructing the electrical power system for the International Space Station (ISS), which circles the Earth every 90 minutes in a low Earth orbit (LEO). For approximately 55 minutes of this orbit, the ISS is in sunlight, and for the remaining 35 minutes, the ISS is in the Earth s shadow (eclipse). The electrical power system must not only provide power during the sunlight portion by means of the solar arrays, but also store energy for use during the eclipse. Nickel-hydrogen (Ni/H2) battery cells were selected as the energy storage systems for ISS. Each battery Orbital Replacement Unit (ORU) comprises 38 individual series-connected Ni/H2 battery cells, and there are 48 battery ORU s on the ISS. On the basis of a limited Ni/H2 LEO data base on life and performance characteristics, the NASA Glenn Research Center at Lewis Field commenced testing through two test programs: one in-house and one at the Naval Surface Warfare Center in Crane, Indiana.

  1. Genotoxicity Testing on the International Space Station: Preparatory Work on the Experiment TRIPLE-LUX

    Science.gov (United States)

    Stojicic, N.; Walrafen, D.; Rabbow, E.; Baumstark-Khan, C.; Rettberg, P.; Weisshaar, M. P.; Horneck, G.

    Harmful environmental factors - namely ionizing radiation - will continue to influence future manned space missions. The Radiation Biology Unit at the German Aerospace Center (DLR) develops cellular monitoring systems, which include bacterial and mammalian cell systems capable of recognizing DNA damage as a consequence of the presence of genotoxic conditions. Such a bioassay is the SWITCH test, which is part of the German space experiment ``Gene, immune and cellular responses to single and combined space flight conditions'' (TRIPLE-LUX) which has been selected by NASA to be performed on the International Space Station. It will supply basic information on the genotoxic response to radiation applied in microgravity. The biological end-point under investigation will depend on the bacterial SOS response brought about by genetically modified bacteria that are transformed with the pSWITCH plasmid (constructed from the plasmids pPLS-1 and pGFPuv). This luminescent/fluorescent bioassay for rapid toxicity (genotoxicity and cytotoxicity) testing, the SWITCH test (SWITCH: {S}almonella {W}eighting of {I}nduced {T}oxicity {C}yto/GenoTox for Human {H}ealth), makes use of two sensing and reporting systems for the two biological endpoints under investigation: the SOS-Lux test and the LAC-Fluoro test. The SWICH plasmid carries the promoterless lux operon of Photobacterium leiognathi as reporter element under the control of the DNA-damage dependent SOS promoter of ColD as sensor element (for genotoxicity testing) and the sequences for a hybrid protein consisting of ß-galactosidase and GFPuv of Aequorea victoria as reporter element under the control of the (in Salmonella constitutively active) LAC promoter of Escherichia coli as sensor element (for cytotoxicity testing). The system has worked properly for terrestrial applications during the first experiments. Experiments using X-rays and UV radiation of various qualities (from UVC to UVA) have given insights into cellular mechanisms

  2. The Need and Opportunity for an Integrated Research, Development and Testing Station in the Alaskan High Arctic

    Science.gov (United States)

    Hardesty, J. O.; Ivey, M.; Helsel, F.; Dexheimer, D.; Cahill, C. F.; Bendure, A.; Lucero, D. A.; Roesler, E. L.

    2016-12-01

    This presentation will make the case for development of a permanent integrated research and testing station at Oliktok Point, Alaska; taking advantage of existing assets and infrastructure, controlled airspace, an active UAS program and local partnerships. Arctic research stations provide critical monitoring and research on climate change for conditions and trends in the Arctic. The US Chair of the Arctic Council has increased awareness of gaps in our understanding of Artic systems, scarce monitoring, lack of infrastructure and readiness for emergency response. Less sea ice brings competition for commercial shipping and resource extraction. Search and rescue, pollution mitigation and safe navigation need real-time, wide-area monitoring to respond to events. Multi-national responses for international traffic will drive a greater security presence to protect citizens and sovereign interests. To address research and technology gaps, there is a national need for a High Arctic Station with an approach that partners stakeholders from science, safety and security to develop comprehensive solutions. The Station should offer year-round use, logistic support and access to varied ecological settings; phased adaptation to changing needs; and support testing of technologies such as multiple autonomous platforms, renewable energies and microgrids, and sensors in Arctic settings. We propose an Arctic Station at Oliktok Point, Alaska. Combined with the Toolik Field Station and Barrow Environmental Observatory, they form a US network of Arctic Stations. An Oliktok Point Station can provide complementary and unique assets that include: ocean access, and coastal and terrestrial systems; road access; controlled airspaces on land and ocean; nearby air facilities, medical and logistic support; atmospheric observations from an adjacent ARM facility; connections to Barrow and Toolik; fiber-optic communications; University of Alaska Fairbanks UAS Test Facility partnership; and an airstrip

  3. Uptake of faecal immunochemical test screening among nonparticipants in a flexible sigmoidoscopy screening programme.

    Science.gov (United States)

    Hol, Lieke; Kuipers, Ernst J; van Ballegooijen, Marjolein; van Vuuren, Anneke J; Reijerink, Jaqueline C I Y; Habbema, Dik J F; van Leerdam, Monique E

    2012-05-01

    Screening programmes based on single modality testing may prevent individuals with a preference for a different test from participating. We conducted a population-based trial to determine whether nonparticipants in flexible sigmoidoscopy (FS) screening were willing to attend faecal immunochemical test (FIT) screening. In total, 8,407 subjects were invited in a primary FS screening programme. Invitees did not know at the time of FS invitation that nonparticipants would be offered FIT screening. A total of 4,407 nonparticipants of FS screening were invited for FIT screening (cut-off 50 ng haemoglobin/ml). The participation rate to FS screening was 31% [95% confidence interval (CI): 30-32%]. Among the FS nonparticipants 25% (CI: 24-26%) did attended FIT screening. The participation rate of the two-stage recruitment for FS and FIT screening was 45% (CI: 44-46%). FIT screenees were older (p = 0.02), more often women (p < 0.001) and had a lower social economic status (p = 0.01) than FS screenees. The detection rate (DR) for advanced adenoma was 3.5% (CI: 2.5-4.8%), and for colorectal cancer (CRC) it was 0.3% (CI: 0.1-0.8%) among participants to FIT screening. The DR of the two-stage recruitment was 6.1% (n = 202) for an advanced adenoma and 0.5% (n = 16) for a CRC. In conclusion, offering FIT screening to nonparticipants in a FS screening programme increases the overall participation rate considerably, as a quarter of nonparticipants of FS screening was willing to attend FIT screening. The participation rate remains lower for primary FIT screening in the same population (62%). Women in the target population were more likely to refuse FS than FIT screening. Countries introducing FS screening should be aware of these preferences. Copyright © 2011 UICC.

  4. Utilization of the International Space Station for Crew Autonomous Scheduling Test (CAST)

    Science.gov (United States)

    Healy, Matthew; Marquez, Jesica; Hillenius, Steven; Korth, David; Bakalyar, Laure Rush; Woodbury, Neil; Larsen, Crystal M.; Bates, Shelby; Kockler, Mikayla; Rhodes, Brooke; Moore, William E., III; Deliz, Ivonne; Kanefsky, Bob; Zheng, Jimin; Henninger, Ashley; Edhlund, Isabelle; Smith, Kate; Kockler, William; Silva-Martinez, Jackelynne

    2017-01-01

    The United States space policy is evolving toward missions beyond low Earth orbit. In an effort to meet that policy, NASA has recognized Autonomous Mission Operations (AMO) as a valuable capability. Identified within AMO capabilities is the potential for autonomous planning and replanning during human spaceflight operations. That is allowing crew members to collectively or individually participate in the development of their own schedules. Currently, dedicated mission operations planners collaborate with international partners to create daily plans for astronauts aboard the International Space Station (ISS), taking into account mission requirements, ground rules, and various vehicle and payload constraints. In future deep space operations the crew will require more independence from ground support due to communication transmission delays. Furthermore, crew members who are provided with the capability to schedule their own activities are able to leverage direct experience operating in the space environment, and possibly maximize their efficiency. CAST (Crew Autonomous Scheduling Test) is an ISS investigation designed to analyze three important hypotheses about crew autonomous scheduling. First, given appropriate inputs, the crew is able to create and execute a plan in a reasonable period of time without impacts to mission success. Second, the proximity of the planner, in this case the crew, to the planned operations increases their operational efficiency. Third, crew members are more satisfied when given a role in plan development. This paper presents the results from a single astronaut test subject who participated in five CAST sessions. The details on the operational philosophy of CAST are discussed, including the approach to crew training, selection criteria for test days, and data collection methods. CAST is a technology demonstration payload sponsored by the ISS Research Science and Technology Office, and performed by experts in Mission Operations Planning from

  5. Experimental testing of impact force on rigid and flexible barriers - A comparison

    Science.gov (United States)

    Nagl, Georg; Hübl, Johannes; Chiari, Michael

    2016-04-01

    The Trattenbach endangers the main western railway track of Austria by floods and debris flows. Three check dams for debris retention were built in the proximal fan area several decades ago. With regard to an improvement of the protective function, these structures have to be renewed. The recent concept of the uppermost barrier is a type of an energy dissipation net structure, stopping debris flows with the ability of self-cleaning by subsequent floods or by machinery employment. The access to the basin is achieved through the slit when the net has been removed. This technical structure consists of a rigid open crown dam with a 4m wide slit. This slit is closed with a flexible net. To verify this protective system, 21 small scale experiments were conducted to test and optimize this new type of Slit Net Dam. To determine the forces on the barrier, in a first setup of experiments the impact forces on a rigid wall with 24 load cells were measured. In the second setup the slit barrier with the net was investigated. On four main cables the anchor forces were measured. In a further setup the basal distance between the channel and lowest net was varied. To study the emptying of the basin and the dosing effect on debris flows.

  6. International Space Station (ISS) Bacterial Filter Elements (BFEs): Filter Efficiency and Pressure Testing of Returned Units

    Science.gov (United States)

    Green, Robert D.; Agui, Juan H.; Vijayakumar, R.

    2017-01-01

    The air revitalization system aboard the International Space Station (ISS) provides the vital function of maintaining a clean cabin environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of sedimentation due to the microgravity environment in Low Earth Orbit (LEO). The ISS Environmental Control and Life Support (ECLS) system architecture in the U.S. Segment uses a distributed particulate filtration approach consisting of traditional High-Efficiency Particulate Adsorption (HEPA) media filters deployed at multiple locations in each U.S. Segment module; these filters are referred to as Bacterial Filter Elements, or BFEs. These filters see a replacement interval, as part of maintenance, of 2-5 years dependent on location in the ISS. In this work, we present particulate removal efficiency, pressure drop, and leak test results for a sample set of 8 BFEs returned from the ISS after filter replacement. The results can potentially be utilized by the ISS Program to ascertain whether the present replacement interval can be maintained or extended to balance the on-ground filter inventory with extension of the lifetime of ISS beyond 2024. These results can also provide meaningful guidance for particulate filter designs under consideration for future deep space exploration missions.

  7. A test of Automatic Blowing snow Station (ABS) in the French Alps

    Science.gov (United States)

    Ito, Yoichi; Naaim-Bouvet, Florence; Nishimura, Kouichi; Bellot, Hervé; Fontaine, Firmin

    2015-04-01

    Blowing snow is a significant factor to estimate snow distribution in alpine, Arctic and Antarctic regions. The Snow Particle Counter (SPC) is well used for mass flux measurement of the blowing snow, however, the SPC deployment is not always possible for automatic observation under harsh conditions. Recently Automatic Blowing snow Station (ABS), which is a simpler device than the SPC, have been developed in Japan. We installed the ABS system with the SPCs at the Lac Blanc Pass in the French Alps (2700 m a.s.l.) to examine the relationship between the ABS output and snow particle mass flux. The ABS worked well, without problems, for the entire 4-month period in the winter 2014. The ABS output was converted to mass flux using wind-dependent power function which obtained from calibration procedure in a cold wind-tunnel. The mass flux obtained from the ABS showed a good agreement with the SPC, particularly around the peak of blowing snow event. Based on tests under controlled (cold wind-tunnel) and field conditions, we conclude that the ABS is suitable for practical use.

  8. Observational study: microgravity testing of a phase-change reference on the International Space Station.

    Science.gov (United States)

    Topham, T Shane; Bingham, Gail E; Latvakoski, Harri; Podolski, Igor; Sychev, Vladimir S; Burdakin, Andre

    2015-01-01

    Orbital sensors to monitor global climate change during the next decade require low-drift rates for onboard thermometry, which is currently unattainable without on-orbit recalibration. Phase-change materials (PCMs), such as those that make up the ITS-90 standard, are seen as the most reliable references on the ground and could be good candidates for orbital recalibration. Space Dynamics Lab (SDL) has been developing miniaturized phase-change references capable of deployment on an orbital blackbody for nearly a decade. Improvement of orbital temperature measurements for long duration earth observing and remote sensing. To determine whether and how microgravity will affect the phase transitions, SDL conducted experiments with ITS-90 standard material (gallium, Ga) on the International Space Station (ISS) and compared the phase-change temperature with earth-based measurements. The miniature on-orbit thermal reference (MOTR) experiment launched to the ISS in November 2013 on Soyuz TMA-11M with the Expedition 38 crew and returned to Kazakhstan in March 2014 on the Soyuz TMA-10 spacecraft. MOTR tested melts and freezes of Ga using repeated 6-h cycles. Melt cycles obtained on the ground before and after launch were compared with those obtained on the ISS. To within a few mK uncertainty, no significant difference between the melt temperature of Ga at 1 g and in microgravity was observed.

  9. Space Station and Shuttle Payloads: Rack Insertion Device Pneumatic Assembly Setup and Test

    Science.gov (United States)

    Conde, Nathan

    2007-01-01

    As part of my KSC summer internship, I was given the very cool task of writing a test preparation sheet (TPS). A TPS is a set of instructions for certain procedures or tasks, and serves as the documentation for the tasks. TPSs guide task leaders and technicians throughout the work procedures, safely, informing them of what steps will be hazardous, what precautions must be taken, and what to do in the case of an accident or emergency. I was placed in Boeing's Resupply & Return Division (R&R). R&R is responsible for sending up food and supplies to the International Space Station (ISS) with the use of three Italian Multi Purpose Logistics Modules - Leonardo, Donatello, and Raffaello. The supplies are loaded into Resupply Stowage Racks (RSRs) or Resupply Stowage Platforms (RSPs) (though, both are usually referred to as racks), depending on their size and shape. These racks are loaded into the modules with the help of a specialized crane known as the Rack Insertion Device (RID). The RID rests on four pneumatic air jacks, these allow for an operator to raise or lower the RID. The pneumatic air system supplies the air jacks with the necessary air pressure required to lift the RID.

  10. Solid-state lighting for the International Space Station: Tests of visual performance and melatonin regulation

    Science.gov (United States)

    Brainard, George C.; Coyle, William; Ayers, Melissa; Kemp, John; Warfield, Benjamin; Maida, James; Bowen, Charles; Bernecker, Craig; Lockley, Steven W.; Hanifin, John P.

    2013-11-01

    The International Space Station (ISS) uses General Luminaire Assemblies (GLAs) that house fluorescent lamps for illuminating the astronauts' working and living environments. Solid-state light emitting diodes (LEDs) are attractive candidates for replacing the GLAs on the ISS. The advantages of LEDs over conventional fluorescent light sources include lower up-mass, power consumption and heat generation, as well as fewer toxic materials, greater resistance to damage and long lamp life. A prototype Solid-State Lighting Assembly (SSLA) was developed and successfully installed on the ISS. The broad aim of the ongoing work is to test light emitted by prototype SSLAs for supporting astronaut vision and assessing neuroendocrine, circadian, neurobehavioral and sleep effects. Three completed ground-based studies are presented here including experiments on visual performance, color discrimination, and acute plasma melatonin suppression in cohorts of healthy, human subjects under different SSLA light exposure conditions within a high-fidelity replica of the ISS Crew Quarters (CQ). All visual tests were done under indirect daylight at 201 lx, fluorescent room light at 531 lx and 4870 K SSLA light in the CQ at 1266 lx. Visual performance was assessed with numerical verification tests (NVT). NVT data show that there are no significant differences in score (F=0.73, p=0.48) or time (F=0.14, p=0.87) for subjects performing five contrast tests (10%-100%). Color discrimination was assessed with Farnsworth-Munsell 100 Hue tests (FM-100). The FM-100 data showed no significant differences (F=0.01, p=0.99) in color discrimination for indirect daylight, fluorescent room light and 4870 K SSLA light in the CQ. Plasma melatonin suppression data show that there are significant differences (F=29.61, pmelatonin for five corneal irradiances, ranging from 0 to 405 μW/cm2 of 4870 K SSLA light in the CQ (0-1270 lx). Risk factors for the health and safety of astronauts include disturbed circadian

  11. Development and test of flexible film coupon strips for use as a sampling technique

    Science.gov (United States)

    Aldridge, C.

    1969-01-01

    Film consisting of a gelatin base serves as a flexible, water soluble microbiological assay coupon for clean room use. It is nontoxic to microorganisms and capable of remaining unchanged during periods of storage.

  12. Quality Test of Flexible Flat Cable (FFC) With Short Open Test Using Law Ohm Approach through Embedded Fuzzy Logic Based On Open Source Arduino Data Logger

    Science.gov (United States)

    Rohmanu, Ajar; Everhard, Yan

    2017-04-01

    A technological development, especially in the field of electronics is very fast. One of the developments in the electronics hardware device is Flexible Flat Cable (FFC), which serves as a media liaison between the main boards with other hardware parts. The production of Flexible Flat Cable (FFC) will go through the process of testing and measuring of the quality Flexible Flat Cable (FFC). Currently, the testing and measurement is still done manually by observing the Light Emitting Diode (LED) by the operator, so there were many problems. This study will be made of test quality Flexible Flat Cable (FFC) computationally utilize Open Source Embedded System. The method used is the measurement with Short Open Test method using Ohm’s Law approach to 4-wire (Kelvin) and fuzzy logic as a decision maker measurement results based on Open Source Arduino Data Logger. This system uses a sensor current INA219 as a sensor to read the voltage value thus obtained resistance value Flexible Flat Cable (FFC). To get a good system we will do the Black-box testing as well as testing the accuracy and precision with the standard deviation method. In testing the system using three models samples were obtained the test results in the form of standard deviation for the first model of 1.921 second model of 4.567 and 6.300 for the third model. While the value of the Standard Error of Mean (SEM) for the first model of the model 0.304 second at 0.736 and 0.996 of the third model. In testing this system, we will also obtain the average value of the measurement tolerance resistance values for the first model of - 3.50% 4.45% second model and the third model of 5.18% with the standard measurement of prisoners and improve productivity becomes 118.33%. From the results of the testing system is expected to improve the quality and productivity in the process of testing Flexible Flat Cable (FFC).

  13. Stray light test station for measuring point source transmission and thermal background of visible and infrared sensors

    Science.gov (United States)

    Peterson, Gary L.

    2008-08-01

    Breault Research Organization has designed and built a stray light test station. The station measures the point source transmission and background thermal irradiance of visible and infrared sensors. Two beam expanders, including a large 0.89 meter spherical mirror, expand and collimate light from laser sources at 0.658 and 10.6 µm. The large mirror is mounted on a gimbal to illuminate sensors at off-axis angles from 0° to 10°, and azimuths from 0° to 180°. Sensors with apertures as large as 0.3 meters can be tested with the existing facility. The large mirror is placed within a vacuum chamber so cryogenic infrared sensors can be tested in a vacuum environment. A dark cryogenic cold plate can be translated into the field of view of a sensor to measure its background thermal irradiance.

  14. Flexible neutron shielding composite material of EPDM rubber with boron trioxide: Mechanical, thermal investigations and neutron shielding tests

    Science.gov (United States)

    Özdemir, T.; Güngör, A.; Reyhancan, İ. A.

    2017-02-01

    In this study, EPDM and boron trioxide composite was produced and mechanical, thermal and neutron shielding tests were performed. EPDM rubber (Ethylene Propylene Diene Monomer) having a considerably high hydrogen content is an effective neutron shielding material. On the other hand, the materials containing boron components have effective thermal neutron absorption crossection. The composite of EPDM and boron trioxide would be an effective solution for both respects of flexibility and effectiveness for developing a neutron shielding material. Flexible nature of EPDM would be a great asset for the shielding purpose in case of intervention action to a radiation accident. The theoretical calculations and experimental neutron absorption tests have shown that the results were in parallel and an effective neutron shielding has been achieved with the use of the developed composite material.

  15. Experimental Test Rig for Optimal Control of Flexible Space Robotic Arms

    Science.gov (United States)

    2016-12-01

    arm slew, camera slewing, or solar panel deployment can impart vibrations on the entire spacecraft. Vibrations on a spacecraft affect the components...71 viii 2. Refined Post-process Development ............................................73 E. IMU ANGLE MEASUREMENTS...Model for Simple Mass-Spring System .....................................34 Figure 17. Angle and Rate Response of Flexible System Model when

  16. Retracted article: Flexible Fourier Stationary Test in GDP per capita for Central Eastern European Countries

    Directory of Open Access Journals (Sweden)

    Meng-Nan Zhu

    2011-06-01

    Full Text Available Statement of Retraction (http://www.efri.uniri.hr/prikaz.asp?txt_id=7366 This is to notify our respectful reading public that the Editorial Board of the journal Zbornik radova Ekonomskog fakulteta u Rijeci, časopis za ekonomsku teoriju i praksu/ Proceedings of Rijeka Faculty of Economics, Journal of Economics and Business has retracted the following article from publication: “Flexible Fourier Stationary Test in GDP per capita for Central Eastern European Countries“, by Hsu-Ling Chang, Chi-Wei Su, Meng-Nan Zhu, published in our journal Zbornik radova Ekonomskog fakulteta u Rijeci, časopis za ekonomsku teoriju i praksu/ Proceedings of Rijeka Faculty of Economics, Journal of Economics and Business, 2011, vol. 29 (1, pp. 51-63 and almost concurrently published in the journal Eastern European Economics, 2011, vol. 49 (3, pp. 54-65. Being in contact with Josef C Brada, Professor Emeritus, Editor of the journal Eastern European Economics (EEE, we realized that the paper had been sent to both journals, although first published in the EEE and then in our Journal. According to professor Brada’s and our analysis, the paper published in these two journals is exactly the same, except for minor differences in wording, most likely due to editing the text before publication. The outstanding differences are in the title and the fact that the paper published in our Journal has three authors and in EEE journal has two. Whatsoever, owing to the fact that the article had been sent to both journals almost at the same time, it had been impossible to find out the case during the review procedure. Due to this unpleasant situation, our Editorial Board would like to inform our valuable readers that all the necessary measures to retract the paper from our publication have been undertaken and according to publishing ethical principles, cooperation with the authors of the retracted paper have been stopped. Although, in this case neither EEE nor our Journal had any

  17. Alterations of Renal Function Tests of Filling Station Workers with Respect of Genetic Polymorphisms of GSTM1 and GSTT1

    Directory of Open Access Journals (Sweden)

    M. Ansari-Lari

    2004-04-01

    Full Text Available The possible health effects of chronic exposure to petroleum products, in particular exposure to gasoline is an issue of public health concern. Filling station workers are at great risk of exposure to gasoline. To determine the health effects of gasoline exposure on filling station workers, a cross-sectional study was conducted in Shiraz on 56 male gasoline workers and 56 age and sex matched control subjects with no occupational exposure to gasoline. Renal function test was done in the study population. To elucidate the role of hepatic detoxifying enzymes, the genotypes of glutathione S-transferases (GST M1 and T1 were determined. Data analysis was done by multiple regression and nonparametric Kruskal- Wallis test. Results showed that all measurements were in normal range, although subclinical changes were detected in some indices. The present results showed that exposure to gasoline was associated with increased serum creatinine (t=3.33, P=0.001. No difference was detected for this finding in workers with different GST genotypes. Overall due to detection of subclinical changes in renal tests in gasoline station workers, exposure limitation and administrating safety devices is recommended. Also for monitoring health status of workers, doing baseline renal tests and repeating them in appropriate interval is suggested.

  18. Construction and preoperational test of Kashiwasaki-Kariwa Nuclear Power Station Unit No. 6

    Energy Technology Data Exchange (ETDEWEB)

    Natsume, Nobuo; Noda, Hiroshi [Tokyo Electric Power Co. (Japan)

    1996-12-31

    Unit 6 of the Kashiwazaki-Kariwa nuclear power station of Tokyo Electric Power Company, the world`s first advanced boiling water reactor (ABWR), is progressing ahead of the originally established schedule since the start of its construction in September 1991, and commercial operation is scheduled to start before the end of 1996.

  19. Monitoring of air radioactivity at the Jungfraujoch research station: Test of a new high volume aerosol sampler

    OpenAIRE

    Flury, Thomas; Völkle, Hansruedi

    2008-01-01

    The Swiss Federal Office of Public Health (SFOPH) is responsible for the surveillance of environmental radioactivity in Switzerland and for the protection of the public from ionizing and non-ionizing radiation. In order to improve the Swiss radioactivity monitoring network, a new high volume air sampler (DIGITEL DHA-80) was tested in Fribourg and at the Jungfraujoch High Altitude Research Station at 3454 m. The filters are analyzed in the laboratory by a high purity coaxial germanium detector...

  20. Corrective action decision document second gas station, Tonopah Test Range, Nevada (Corrective Action Unit No. 403). Revision No. 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-06-01

    This Corrective Action Decision Document (CADD) for Second Gas Station has been developed for the U.S. Department of Energy`s (DOE) Nevada Environmental Restoration Project to meet the requirements of the Federal Facility Agreement and Consent Order (FFACO) of 1996 as stated in Appendix VI, {open_quotes}Corrective Action Strategy{close_quotes}. The Second Gas Station Corrective Action Site (CAS) No. 03-02-004-03 is the only CAS in CAU No. 403. The Second Gas Station CAS is located within Area 3 of the Tonopah Test Range (TTR), west of the Main Road at the location of former Underground Storage Tanks (USTs) and their associated fuel dispensary stations. The TTR is approximately 225 kilometers (km) (140 miles [mi]) northwest of Las Vegas, Nevada, by air and approximately 56 km (3 5 mi) southeast of Tonopah, Nevada, by road. The TTR is bordered on the south, east, and west by the Nellis Air Force Range and on the north by sparsely populated public land administered by the Bureau of Land Management and the U.S. Forest Service.

  1. Flexibility and resistance to cyclic fatigue of endodontic instruments made with different nickel-titanium alloys: a comparative test.

    Science.gov (United States)

    Pongione, Giancarlo; Pompa, Giorgio; Milana, Valerio; Di Carlo, Stefano; Giansiracusa, Alessio; Nicolini, Emanuele; De Angelis, Francesca

    2012-07-01

    A new manufacturing method aiming at to producing more flexible and resistant NiTi endodontic instruments has been recently developed (Hyflex, produced with CM wire). The purpose of the study was to determine whether this new manufacturing method produces NiTi instruments (Hyflex) of superior flexibility and/or superior resistance to cyclic fatigue, when compared with instruments produced by a traditional manufacturing process or thermally treated NiTi alloy (M-wire). Twelve .06 size 25 Hyflex instruments (Coltene, Allstatten, Switzerland), and twelve 06.25 Vortex instruments (Dentsply-Tulsa, OK, USA) and twelve 06.25 Endosequence instruments (Brasseler, Savannah, GA, USA) were initially evaluated for stiffness on bending, followed by a cyclic fatigue test. For the stiffness test test procedures strictly followed ISO 3630-1, and bending moment was measured when the instrument attained a 45 degrees bend. The cyclic fatigue test was performed in a customized artificial stainless steel canal (60° degree curvature with 5 mm radius). Instruments were rotated at 300 rpm until fracture. All data obtained were recorded and statistically analyzed using an ANOVA test. Statistical analysis of data showed that bending moments were significantly greater (P < .05) for Vortex and EndoSequence instruments (mean values 59.06 g/cm and 48,98 g/cm respectively), compared to the Hyflex instruments (mean value 35.60 g/cm). For the cyclic fatigue test Hyflex and Vortex were significantly more resistant than EndoSequence instruments (P < .05). Results of the present study demonstrate the ability of the new CM-wire manufacturing process to produce NiTi rotary instruments more flexible and more resistant to cyclic fatigue than instruments produced by a traditional manufacturing process or a thermally treated NiTi alloy (M-wire).

  2. ON-ORBIT LOAD COMPUTATION AND ANALYSIS OF FLEXIBLE SOLAR ARRAY FOR CHINA SPACE STATION%空间站柔性电池翼在轨载荷计算及分析

    Institute of Scientific and Technical Information of China (English)

    刘芳; 郭其威; 吴松; 肖余之

    2014-01-01

    In order to ensure the huge energy for normal working of China Space Station and less weight costs in launching,China Space Station adopted the large area flexible solar array (LAFSA)design scheme.The LAFSA has complex structures and extremely low frequency,and bearing loads produced by multiple large maneuver pro-cedure in orbit running,so the strength check and parameter design for each load-carrying component become very important segments for the mission's success or failure of China Space Station.This paper established a sim-plified linear modal for the flexible solar array of China Space Station from the perspective of engineering applica-tions,and computed the loads of every important component of the flexible solar array in on-orbit large maneuver procedures,which can be used as the instruction for strength check and lightweight design of the LAFSA.%为了保证空间站正常运行所需要的大量能源及发射入轨时的较小重量代价,我国空间站采用大面积柔性电池翼的设计方案。大柔性电池翼因其结构复杂且频率极低,在轨运行时又要承受多次大机动过程产生的载荷,各承力组件的强度校核和参数设计成为影响整个空间站任务成败的重要环节。本文从工程应用角度出发建立了空间站柔性电池翼的线性简化模型,计算并分析了柔性电池翼在轨大机动过程中各关键组件的载荷,计算结果可对大柔性电池翼的强度校核和减重设计起到一定指导作用。

  3. Test of the uplift of Tibetan Plateau by FG5 absolute gravimeter at Lhasa station

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The uplift of the Tibetan Plateau has been monitored by the FG5 absolute gravimeter, whose observing accuracy is as high as 2×10-8 m/s2. The analysis of the gravity observation results at the Lhasa station in 1999 and 1993 shows that the gravity value has decreased by 12×10-8 m/s2, and it is confirmed that the Lhasa region is uplifting at a rate of 10 mm/a.

  4. L1 Adaptive Control Law for Flexible Space Launch Vehicle and Proposed Plan for Flight Test Validation

    Science.gov (United States)

    Kharisov, Evgeny; Gregory, Irene M.; Cao, Chengyu; Hovakimyan, Naira

    2008-01-01

    This paper explores application of the L1 adaptive control architecture to a generic flexible Crew Launch Vehicle (CLV). Adaptive control has the potential to improve performance and enhance safety of space vehicles that often operate in very unforgiving and occasionally highly uncertain environments. NASA s development of the next generation space launch vehicles presents an opportunity for adaptive control to contribute to improved performance of this statically unstable vehicle with low damping and low bending frequency flexible dynamics. In this paper, we consider the L1 adaptive output feedback controller to control the low frequency structural modes and propose steps to validate the adaptive controller performance utilizing one of the experimental test flights for the CLV Ares-I Program.

  5. Methods for flexible sample-size design in clinical trials: Likelihood, weighted, dual test, and promising zone approaches.

    Science.gov (United States)

    Shih, Weichung Joe; Li, Gang; Wang, Yining

    2016-03-01

    Sample size plays a crucial role in clinical trials. Flexible sample-size designs, as part of the more general category of adaptive designs that utilize interim data, have been a popular topic in recent years. In this paper, we give a comparative review of four related methods for such a design. The likelihood method uses the likelihood ratio test with an adjusted critical value. The weighted method adjusts the test statistic with given weights rather than the critical value. The dual test method requires both the likelihood ratio statistic and the weighted statistic to be greater than the unadjusted critical value. The promising zone approach uses the likelihood ratio statistic with the unadjusted value and other constraints. All four methods preserve the type-I error rate. In this paper we explore their properties and compare their relationships and merits. We show that the sample size rules for the dual test are in conflict with the rules of the promising zone approach. We delineate what is necessary to specify in the study protocol to ensure the validity of the statistical procedure and what can be kept implicit in the protocol so that more flexibility can be attained for confirmatory phase III trials in meeting regulatory requirements. We also prove that under mild conditions, the likelihood ratio test still preserves the type-I error rate when the actual sample size is larger than the re-calculated one.

  6. Sperm tail flexibility test: a simple test for selecting viable spermatozoa for intracytoplasmic sperm injection from semen samples without motile spermatozoa

    Directory of Open Access Journals (Sweden)

    Soares Jonathas Borges

    2003-01-01

    Full Text Available PURPOSE: The objective was to describe the results of the injection of immotile spermatozoa with flexible tails when only immotile spermatozoa are present in the semen sample. METHODS: A retrospective study was conducted to analyze the procedure results for 10 couples who participated in our intracytoplasmic sperm injection program. The sperm tail was considered flexible when it moved up and down independently of the head movement, and it was considered inflexible when the movement occurred together (tail plus head. The fertilization and pregnancy rate were analyzed. RESULTS: The normal fertilization rate (presence of 2 pronuclei was 30.3% (40/132, and the abnormal fertilization rate (presence of less than or more than 2 pronuclei was 6.81% (9/132. A total of 52 embryos were obtained with 9 transfer procedures performed (pregnancy rate: 11.12%. CONCLUSIONS: The sperm tail flexibility test (STFT is an easy and cost-effective way for selecting viable immotile spermatozoa and can be used as an alternative method for determining the viability of spermatozoa. This test seems to be a simple and risk-free method when compared to the swelling test.

  7. ASME XI stroke time testing of solenoid valves at Connecticut Yankee Station

    Energy Technology Data Exchange (ETDEWEB)

    Martin, C.W.

    1996-12-01

    Connecticut Yankee Atomic Power Company has developed the capability of measuring the stroke times of AC and DC solenoid valves. This allows the station to measure the stroke time of any solenoid valve in the plant, even those valves which do not have valve stem position indicators. Connecticut Yankee has adapted the ITI MOVATS Checkmate 3 system, using a signal input from a Bruel and Kjaer (B&K) Model 4382 acoustic accelerometer and the Schaumberg Campbell Associates (SCA) Model SCA-1148 dual sensor, which is a combined accelerometer and gaussmeter.

  8. Progress on control experiments of flexible structures

    Science.gov (United States)

    Juang, Jer-Nan

    1990-01-01

    Progress at the NASA Langley Research Center in the area of control experiments for flexible structures is described. First the author presents the experimental results for a linear model which represents slewing maneuvers of a generic space station solar panel carried out to evaluate experimentally some control technologies. Then the status of the rotational/translational maneuvering experiment of a flexible steel panel carried by a translation cart is presented. Finally, experimental results of the NASA minimast testbed using velocity command stepper motors as reaction mass reactors are shown. All the test configurations are briefly described, including actuator and sensor, test setup, and test software. The status of some research activities oriented primarily to the experimental methods for control of flexible structures is presented.

  9. Load converter interactions with the secondary system in the Space Station Freedom power management and distribution dc test bed

    Science.gov (United States)

    Lebron, Ramon C.

    1992-01-01

    The NASA LeRC in Cleveland, Ohio, is responsible for the design, development, and assembly of the Space Station Freedom (SSF) Electrical Power System (EPS). In order to identify and understand system level issues during the SSF program design and development phases, a system Power Management and Distribution (PMAD) dc test bed was assembled. Some of the objectives of this test bed facility are the evaluation of, system efficiency, power quality, system stability, and system protection and reconfiguration schemes. In order to provide a realistic operating scenario, dc Load Converter Units are used in the PMAD dc test bed to characterize the user interface with the power system. These units are dc to dc converters that provide the final system regulation before power is delivered to the load. This final regulation is required on the actual space station because the majority of user loads will require voltage levels different from the secondary bus voltage. This paper describes the testing of load converters in an end to end system environment (from solar array to loads) where their interactions and compatibility with other system components are considered. Some of the system effects of interest that are presented include load converters transient behavior interactions with protective current limiting switchgear, load converters ripple effects, and the effects of load converter constant power behavior with protective features such as foldback.

  10. Load converter interactions with the secondary system in the Space Station Freedom power management and distribution DC test bed

    Science.gov (United States)

    Lebron, Ramon C.

    1992-01-01

    The NASA LeRC in Cleveland, Ohio, is responsible for the design, development, and assembly of the Space Station Freedom (SSF) Electrical Power System (EPS). In order to identify and understand system level issues during the SSF Program design and development phases, a system Power Management and Distribution (PMAD) DC test bed was assembled. Some of the objectives of this test bed facility are the evaluation of, system efficiency, power quality, system stability, and system protection and reconfiguration schemes. In order to provide a realistic operating scenario, dc Load Converter Units are used in the PMAD dc test bed to characterize the user interface with the power system. These units are dc to dc converters that provide the final system regulation before power is delivered to the load. This final regulation is required on the actual space station because the majority of user loads will require voltage levels different from the secondary bus voltage. This paper describes the testing of load converters in an end to end system environment (from solar array to loads) where their interactions and compatibility with other system components are considered. Some of the system effects of interest that are presented include load converters transient behavior interactions with protective current limiting switchgear, load converters ripple effects, and the effects of load converter constant power behavior with protective features such as foldback.

  11. A Flexible Computational Framework Using R and Map-Reduce for Permutation Tests of Massive Genetic Analysis of Complex Traits.

    Science.gov (United States)

    Mahjani, Behrang; Toor, Salman; Nettelblad, Carl; Holmgren, Sverker

    2017-01-01

    In quantitative trait locus (QTL) mapping significance of putative QTL is often determined using permutation testing. The computational needs to calculate the significance level are immense, 10(4) up to 10(8) or even more permutations can be needed. We have previously introduced the PruneDIRECT algorithm for multiple QTL scan with epistatic interactions. This algorithm has specific strengths for permutation testing. Here, we present a flexible, parallel computing framework for identifying multiple interacting QTL using the PruneDIRECT algorithm which uses the map-reduce model as implemented in Hadoop. The framework is implemented in R, a widely used software tool among geneticists. This enables users to rearrange algorithmic steps to adapt genetic models, search algorithms, and parallelization steps to their needs in a flexible way. Our work underlines the maturity of accessing distributed parallel computing for computationally demanding bioinformatics applications through building workflows within existing scientific environments. We investigate the PruneDIRECT algorithm, comparing its performance to exhaustive search and DIRECT algorithm using our framework on a public cloud resource. We find that PruneDIRECT is vastly superior for permutation testing, and perform 2 ×10(5) permutations for a 2D QTL problem in 15 hours, using 100 cloud processes. We show that our framework scales out almost linearly for a 3D QTL search.

  12. Gust load alleviation wind tunnel tests of a large-aspect-ratio flexible wing with piezoelectric control

    Directory of Open Access Journals (Sweden)

    Ying Bi

    2017-02-01

    Full Text Available An active control technique utilizing piezoelectric actuators to alleviate gust-response loads of a large-aspect-ratio flexible wing is investigated. Piezoelectric materials have been extensively used for active vibration control of engineering structures. In this paper, piezoelectric materials further attempt to suppress the vibration of the aeroelastic wing caused by gust. The motion equation of the flexible wing with piezoelectric patches is obtained by Hamilton’s principle with the modal approach, and then numerical gust responses are analyzed, based on which a gust load alleviation (GLA control system is proposed. The gust load alleviation system employs classic proportional-integral-derivative (PID controllers which treat piezoelectric patches as control actuators and acceleration as the feedback signal. By a numerical method, the control mechanism that piezoelectric actuators can be used to alleviate gust-response loads is also analyzed qualitatively. Furthermore, through low-speed wind tunnel tests, the effectiveness of the gust load alleviation active control technology is validated. The test results agree well with the numerical results. Test results show that at a certain frequency range, the control scheme can effectively alleviate the z and x wingtip accelerations and the root bending moment of the wing to a certain extent. The control system gives satisfying gust load alleviation efficacy with the reduction rate being generally over 20%.

  13. A flexible testing facility for high-power targets (Tiara FP7 program)

    CERN Document Server

    Fusco, Y.; Samec, K.; Kadi, Y.

    2014-01-01

    Building on recent experience in the field of applied physics, TIARA Work package n° 9 focuses on target applications for accelerators in Europe. A roadmap for target development has been derived from major achievements in the EU-FP6 and EU-FP7 programs such as the MEGAPIE and EURISOL experiments. The TIARA management board concluded that a worthwhile continuation of such projects would be in the development of a flexible material irradiation facility easily transportable and which could be installed in different laboratories. The power is limited to 100 kW in a very compact arrangement so as to obtain the best neutron economy from a moderate beam power which is more likely to be found in laboratories across Europe. The challenges posed by such a compact design and accompanying calculations are presented in the current work.

  14. Low-cost extrapolation method for maximal LTE radio base station exposure estimation: test and validation.

    Science.gov (United States)

    Verloock, Leen; Joseph, Wout; Gati, Azeddine; Varsier, Nadège; Flach, Björn; Wiart, Joe; Martens, Luc

    2013-06-01

    An experimental validation of a low-cost method for extrapolation and estimation of the maximal electromagnetic-field exposure from long-term evolution (LTE) radio base station installations are presented. No knowledge on downlink band occupation or service characteristics is required for the low-cost method. The method is applicable in situ. It only requires a basic spectrum analyser with appropriate field probes without the need of expensive dedicated LTE decoders. The method is validated both in laboratory and in situ, for a single-input single-output antenna LTE system and a 2×2 multiple-input multiple-output system, with low deviations in comparison with signals measured using dedicated LTE decoders.

  15. Testing of environmental radiation monitors using the Risø low-level radiation measurement stations

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.

    2000-01-01

    To harmonise the measurement of environmental dose rates from photon radiation within the EU countries. an EU sponsored intercomparison of environmental dose rate meters used for early warning of nuclear accidents was performed in June 1999. The intercomparison was organised by the EURADOS......, Physikalisch Technische Bundesanstalt (Germany) and the Riso National Laboratory (Denmark). This paper describes the free-field irradiation facilities at Rise and some details of the field intercomparison experiments performed at the Riso Natural Environmental Radiation Measurement Station during 3rd and 4th...... June, 1999. The chief aims of such experiments are to allow the participants to check their home calibrations of their detectors and to compare the responses of the individual environmental radiation measurement systems used in the different EU member states and making a link between the different...

  16. Laboratory tests and numerical simulations of brittle marble and squeezing schist at Jinping II hydropower station,China

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    Four 16.7 km-long tunnels with diameters ranging from 12.4 to 14.6 m are now under construction at Jinping II hydropower station along the Yalong River.The tunnels pass through Triassic rocks below Jinping Mountain.The tunnels are characterized with high overburden,long alignment and complex geological conditions.Brittle failure in marble and squeezing in schist are the primary problems in tunnelling.This paper introduces the studies of laboratory tests on Jinping II marble as well as numerical prediction o...

  17. Test report for the infrasound prototype: For a CTBT IMS station

    Energy Technology Data Exchange (ETDEWEB)

    Breding, D.R.; Kromer, R.P. [Sandia National Labs., Albuquerque, NM (United States); Whitaker, R.W.; Sandoval, T. [Los Alamos National Lab., NM (United States)

    1997-11-01

    This document describes the results of the Comprehensive Test Ban Treaty (CTBT) Infrasound Prototype Development Test and Evaluation (DT&E). During DT&E the infrasound prototype was evaluated against requirements listed in the System Requirements Document (SRD) based on the Conference on Disarmament/Ad Hoc Committee on a Nuclear Test Ban/Working Papers 224 and 283 and the Preparatory Commission specifications as defined in CTBT/PC/II/1/Add.2, Appendix X, Table 5. The evaluation was conducted during a two-day period, August 6-7, 18997. The System Test Plan (STP) defined the plan and methods to test the infrasound prototype. Specific tests that were performed are detailed in the Test Procedures (TP).

  18. No trade-off between learning speed and associative flexibility in bumblebees: a reversal learning test with multiple colonies.

    Directory of Open Access Journals (Sweden)

    Nigel E Raine

    Full Text Available Potential trade-offs between learning speed and memory-related performance could be important factors in the evolution of learning. Here, we test whether rapid learning interferes with the acquisition of new information using a reversal learning paradigm. Bumblebees (Bombus terrestris were trained to associate yellow with a floral reward. Subsequently the association between colour and reward was reversed, meaning bees then had to learn to visit blue flowers. We demonstrate that individuals that were fast to learn yellow as a predictor of reward were also quick to reverse this association. Furthermore, overnight memory retention tests suggest that faster learning individuals are also better at retaining previously learned information. There is also an effect of relatedness: colonies whose workers were fast to learn the association between yellow and reward also reversed this association rapidly. These results are inconsistent with a trade-off between learning speed and the reversal of a previously made association. On the contrary, they suggest that differences in learning performance and cognitive (behavioural flexibility could reflect more general differences in colony learning ability. Hence, this study provides additional evidence to support the idea that rapid learning and behavioural flexibility have adaptive value.

  19. Baseline and verification tests of the electric vehicle associates' current fare station wagon. Final test report, March 27, 1980-November 6, 1981

    Energy Technology Data Exchange (ETDEWEB)

    Dowgiallo, E.J. Jr.; Chapman, R.D.

    1983-01-01

    The EVA Current Fare Wagon was manufactured by Electric Vehicle Associates, Incorporated (EVA) of Cleveland, Ohio. It is now available from Lectra Motors Corp. of Las Vegas, Nevada. The vehicle was tested under the direction of MERADCOM from 27 March 1980 to 6 November 1981. The tests are part of a Department of Energy project to assess advances in electric vehicle design. This report presents the performance test results on the EVA Current Fare Wagon. The EVA Current Fare Wagon is a 1980 Ford Fairmont station wagon which has been converted to an electric vehicle. The propulsion system is made up of a Cableform controller, a series-wound 30-hp Reliance Electric Motor, and 22 6-V lead-acid batteries. The Current Fare Wagon is also equipped with regenerative braking. Further details of the vehicle are given in the Vehicle Summary Data Sheet, Appendix A. The results of this testing are given in Table 1.

  20. The development and testing of a unique and flexible training module for residents and fellows using digital breast tomosythesis (DBT)

    Science.gov (United States)

    Hakim, Christiane M.; Drescher, John; King, Jill L.; Logue, Durwin; Klym, Amy H.; Gur, David

    2017-03-01

    The transition from FFDM to digital breast tomosynthesis (DBT) necessitates new approaches for training radiology residents and fellows that highlight depiction differences between the same abnormalities on the two modalities. We developed a unique, flexible training module that enables training with complete feedback, as well as testing performance before and after use of this training module. Currently, 219 examinations, with priors and other relevant information, are included. Using a special interface to the Secure View workstation (Hologic), we developed a management program that displays each case in a randomized manner and in a sequential mode (i.e. FFDM first followed by FFDM+DBT) and allows the reader to rate the case followed by viewing the images side by side with results of the full imaging based history (reporting) by the screening interpreter, the diagnostic workup interpreter (when applicable), and the actual pathology (biopsy and/or surgical). This approach allows the reader to review their correct and/or incorrect interpretation at each step of the management decision making. The module also has sets of pre- and post-training cases, allowing for a test-train-test study to be performed, if so desired. Two observer studies using 18 radiologists, residents, and fellows have been performed using this module, to date. The training module was assembled, tested, and implemented. We found it to be extremely flexible and useful in training. After completing two observer performance studies, the module was installed in our clinical facility and is currently being used to train residents and fellows at their own pace. All users found this module to be useful and extremely informative.

  1. Tests of Shaft Seal Systems of Circulation Pumps during Station Blackout

    Energy Technology Data Exchange (ETDEWEB)

    Beisiegel, A.; Foppe, F.; Wich, M.

    2014-07-01

    AREVA GmbH operates a unique Thermal-hydraulic plat form in Germany, France and USA. It is recognised as a test body according to ISO 17025. The Deutsche Akkreditierungsstelle GmbH (DAkkS - German Society for Accreditation) has also certified the Thermal-hydraulic platform as an independent inspection body Type C according to ISO 17020. A part of this platform is the Component Laboratory located in Karlstein, Germany which is in operation since more than 50 years. The testing activities cover a wide range as: Critical Heat Flux Tests, Valve Testing and Environmental Qualification for safety related components. Since 2011 the Component Qualification Karlstein extended their testing scope for different types of Shaft Seal Systems. (Author)

  2. Thermo-Mechanical Test of Seal System in Flexible Pipe End Fittings

    DEFF Research Database (Denmark)

    Banke, Lars

    1999-01-01

    of the seal system geometry and its tolerances necessary to maintain a tight seal. The test is carried out in a purpose built autoclave, in which the seal system can be tested while undergoing variations in pressure and temperature.The paper will present a study on the importance of the geometry of the gasket...

  3. Mobile multimedia antenna systems for station wagons and the achievable diversity effectiveness obtained by analysis of virtual test drives

    Science.gov (United States)

    Hopf, J. F.; Lindenmeier, H. K.; Reiter, L. M.

    2003-04-01

    For modern cars, antennas are required for AM reception, FM and TV diversity reception, weatherband reception (USA), terrestrial digital radio, remote control functions, keyless entry, mobile phone for all worldwide used systems, GPS, and in the future, satellite broadcast radio services. Those services cover the frequency range from 150 kHz up to 2.4 GHz. Such kind of a multiantenna system developed for station wagons is presented in this paper. The obtainable FM and TV diversity effectiveness is discussed for several types of antenna arrangements in detail. This value is the number of fictitious completely decorrelated antenna signals and is obtained by virtual test drives. The characteristic of the respective antennas under test is introduced in the software as antenna pattern, measured or calculated with respect to amplitude and phase. During the computer analysis the car with the antennas is driven virtually through a Rayleigh field scenario with desired and undesired signals.

  4. Overview of New Tools to Perform Safety Analysis: BWR Station Black Out Test Case

    Energy Technology Data Exchange (ETDEWEB)

    D. Mandelli; C. Smith; T. Riley; J. Nielsen; J. Schroeder; C. Rabiti; A. Alfonsi; Cogliati; R. Kinoshita; V. Pasucci; B. Wang; D. Maljovec

    2014-06-01

    Dynamic Probabilistic Risk Assessment (DPRA) methodologies couple system simulator codes (e.g., RELAP, MELCOR) with simulation controller codes (e.g., RAVEN, ADAPT). While system simulator codes accurately model system dynamics deterministically, simulation controller codes introduce both deterministic (e.g., system control logic, operating procedures) and stochastic (e.g., component failures, parameter uncertainties) elements into the simulation. Typically, a DPRA is performed by: 1) sampling values of a set of parameters from the uncertainty space of interest (using the simulation controller codes), and 2) simulating the system behavior for that specific set of parameter values (using the system simulator codes). For complex systems, one of the major challenges in using DPRA methodologies is to analyze the large amount of information (i.e., large number of scenarios ) generated, where clustering techniques are typically employed to allow users to better organize and interpret the data. In this paper, we focus on the analysis of a nuclear simulation dataset that is part of the Risk Informed Safety Margin Characterization (RISMC) Boiling Water Reactor (BWR) station blackout (SBO) case study. We apply a software tool that provides the domain experts with an interactive analysis and visualization environment for understanding the structures of such high-dimensional nuclear simulation datasets. Our tool encodes traditional and topology-based clustering techniques, where the latter partitions the data points into clusters based on their uniform gradient flow behavior. We demonstrate through our case study that both types of clustering techniques complement each other in bringing enhanced structural understanding of the data.

  5. Feasibility of Conducting J-2X Engine Testing at the Glenn Research Center Plum Brook Station B-2 Facility

    Science.gov (United States)

    Schafer, Charles F.; Cheston, Derrick J.; Worlund, Armis L.; Brown, James R.; Hooper, William G.; Monk, Jan C.; Winstead, Thomas W.

    2008-01-01

    A trade study of the feasibility of conducting J-2X testing in the Glenn Research Center (GRC) Plum Brook Station (PBS) B-2 facility was initiated in May 2006 with results available in October 2006. The Propulsion Test Integration Group (PTIG) led the study with support from Marshall Space Flight Center (MSFC) and Jacobs Sverdrup Engineering. The primary focus of the trade study was on facility design concepts and their capability to satisfy the J-2X altitude simulation test requirements. The propulsion systems tested in the B-2 facility were in the 30,000-pound (30K) thrust class. The J-2X thrust is approximately 10 times larger. Therefore, concepts significantly different from the current configuration are necessary for the diffuser, spray chamber subsystems, and cooling water. Steam exhaust condensation in the spray chamber is judged to be the key risk consideration relative to acceptable spray chamber pressure. Further assessment via computational fluid dynamics (CFD) and other simulation capabilities (e.g. methodology for anchoring predictions with actual test data and subscale testing to support investigation.

  6. Baseline and verification tests of the Electric Vehicle Associates' Current Fare Station Wagon. Final test report, 27 March 1980-6 November 1981

    Energy Technology Data Exchange (ETDEWEB)

    Dowgiallo, E.J. Jr; Chapman, R.D.

    1983-01-01

    The EVA Current Fare Station Wagon, an electric vehicle, was tested at MERADCOM as part of a Department of Energy project to characterize the state-of-the-art of electric vehicles. The current Fare Wagon was manufactured in Cleveland, Ohio by Electric Vehicle Associates' Incorporated. It is powered by 22 6-V lead-acid batteries driving a 30-hp d.c. series motor through an SCR controller. The motor drives the rear wheels through a manually operated 4-speed transmission. Regenerative braking was provided.

  7. Risk-based inservice testing program modifications at Palo Verde nuclear generating station

    Energy Technology Data Exchange (ETDEWEB)

    Knauf, S.; Lindenlaub, B.; Linthicum, R.

    1996-12-01

    Arizona Public Service Company (APS) is investigating changes to the Palo Verde Inservice Testing (IST) Program that are intended to result in the reduction of the required test frequency for various valves in the American Society of Mechanical Engineers (ASME) Section XI IST program. The analytical techniques employed to select candidate valves and to demonstrate that these frequency reductions are acceptable are risk based. The results of the Palo Verde probabilistic risk assessment (PRA), updated in June 1994, and the risk significant determination performed as part of the implementation efforts for 10 CFR 50.65 (the maintenance rule) were used to select candidate valves for extended test intervals. Additional component level evaluations were conducted by an `expert panel.` The decision to pursue these changes was facilitated by the ASME Risk-Based Inservice Testing Research Task Force for which Palo Verde is participating as a pilot plant. The NRC`s increasing acceptance of cost beneficial licensing actions and risk-based submittals also provided incentive to seek these changes. Arizona Public Service is pursuing the risk-based IST program modification in order to reduce the unnecessary regulatory burden of the IST program through qualitative and quantitative analysis consistent with maintaining a high level of plant safety. The objectives of this project at Palo Verde are as follows: (1) Apply risk-based technologies to IST components to determine their risk significance (i.e., high or low). (2) Apply a combination of deterministic and risk-based methods to determine appropriate testing requirements for IST components including improvement of testing methods and frequency intervals for high-risk significant components. (3) Apply risk-based technologies to high-risk significant components identified by the {open_quotes}expert panel{close_quotes} and outside of the IST program to determine whether additional testing requirements are appropriate.

  8. High SO{sub 2} removal efficiency testing: Evaluation of high efficiency test results at Hoosier Energy`s Merom Station

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-04-22

    Tests were conducted at Hoosier Energy`s Merom Station 535-MW Units 1 and 2 wet limestone flue gas desulfurization (FGD) systems to evaluate options for achieving high SO{sub 2} removal efficiency. The options tested included use of dibasic acid (DBA) and sodium formate additives as well as operation at higher reagent ratios (higher pH set points). In addition to the tested options, the effectiveness of other potential options was simulated using the Electric Power Research Institute`s FGD Process Integration and Simulation Model (FGDPRISM) after it was calibrated to the system. An economic analysis was done to determine the cost effectiveness of each option. A summary of results is given on the following: SO{sub 2} removal performance; additive consumption; and SO{sub 2} removal upgrade economics.

  9. On Dimensions of OTA Setups for Massive MIMO Base Stations Radiated Testing

    DEFF Research Database (Denmark)

    Kyösti, Pekka; Fan, Wei; Pedersen, Gert F.;

    2016-01-01

    dimensions of the over-the-air (OTA) setups for the performance evaluation of massive multiple-input multiple-output (MIMO) BSs in anechoic chambers with multiple probes. Setup dimension is the major cost factor in the test systems and is thus the key issue to be investigated. The purpose is to determine...... (DoA) estimation algorithm as well as multi-user MIMO sum-rate capacity are investigated to determine the range of the test setup. It was found that the link budget doesn’t support for the measurement distances claimed by the Fraunhofer distance. Most of the utilized metrics, especially the sum rate...

  10. Waste water processing technology for Space Station Freedom - Comparative test data analysis

    Science.gov (United States)

    Miernik, Janie H.; Shah, Burt H.; Mcgriff, Cindy F.

    1991-01-01

    Comparative tests were conducted to choose the optimum technology for waste water processing on SSF. A thermoelectric integrated membrane evaporation (TIMES) subsystem and a vapor compression distillation subsystem (VCD) were built and tested to compare urine processing capability. Water quality, performance, and specific energy were compared for conceptual designs intended to function as part of the water recovery and management system of SSF. The VCD is considered the most mature and efficient technology and was selected to replace the TIMES as the baseline urine processor for SSF.

  11. Waste water processing technology for Space Station Freedom - Comparative test data analysis

    Science.gov (United States)

    Miernik, Janie H.; Shah, Burt H.; Mcgriff, Cindy F.

    1991-01-01

    Comparative tests were conducted to choose the optimum technology for waste water processing on SSF. A thermoelectric integrated membrane evaporation (TIMES) subsystem and a vapor compression distillation subsystem (VCD) were built and tested to compare urine processing capability. Water quality, performance, and specific energy were compared for conceptual designs intended to function as part of the water recovery and management system of SSF. The VCD is considered the most mature and efficient technology and was selected to replace the TIMES as the baseline urine processor for SSF.

  12. International Space Station (ISS) Bacterial Filter Elements (BFEs): Filter Efficiency and Pressure Drop Testing of Returned Units

    Science.gov (United States)

    Green, Robert D.; Agui, Juan H.; Vijayakumar, R.; Berger, Gordon M.; Perry, Jay L.

    2017-01-01

    The air quality control equipment aboard the International Space Station (ISS) and future deep space exploration vehicles provide the vital function of maintaining a clean cabin environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of sedimentation. The ISS Environmental Control and Life Support (ECLS) system architecture in the U.S. Segment uses a distributed particulate filtration approach consisting of traditional High-Efficiency Particulate Air (HEPA) filters deployed at multiple locations in each U.S. Seg-ment module; these filters are referred to as Bacterial Filter Elements, or BFEs. In our previous work, we presented results of efficiency and pressure drop measurements for a sample set of two returned BFEs with a service life of 2.5 years. In this follow-on work, we present similar efficiency, pressure drop, and leak tests results for a larger sample set of six returned BFEs. The results of this work can aid the ISS Program in managing BFE logistics inventory through the stations planned lifetime as well as provide insight for managing filter element logistics for future exploration missions. These results also can provide meaningful guidance for particulate filter designs under consideration for future deep space exploration missions.

  13. Waste Transfer Stations

    DEFF Research Database (Denmark)

    Christensen, Thomas Højlund

    2011-01-01

    tion and transport is usually the most costly part of any waste management system; and when waste is transported over a considerable distance or for a long time, transferring the waste from the collection vehicles to more efficient transportation may be economically beneficial. This involves...... a transfer station where the transfer takes place. These stations may also be accessible by private people, offering flexibility to the waste system, including facilities for bulky waste, household hazardous waste and recyclables. Waste transfer may also take place on the collection route from small...... describes the main features of waste transfer stations, including some considerations about the economical aspects on when transfer is advisable....

  14. Space station common module thermal management: Design and construction of a test bed

    Science.gov (United States)

    Barile, R. G.

    1986-01-01

    In this project, a thermal test bed was designed, simulated, and planned for construction. The thermal system features interior and exterior thermal loads and interfacing with the central-radiator thermal bus. Components of the test bed include body mounted radiator loop with interface heat exchangers (600 Btu/hr); an internal loop with cabin air-conditioning and cold plates (3400 Btu/hr); interface heat exchangers to the central bus (13,000 Btu/hr); and provisions for new technology including advanced radiators, thermal storage, and refrigeration. The apparatus will be mounted in a chamber, heated with lamps, and tested in a vacuum chamber with LN2-cooled walls. Simulation of the test bed was accomplished using a DEC PRO 350 computer and the software package TK! olver. Key input variables were absorbed solar radiation and cold plate loads. The results indicate temperatures on the two loops will be nominal when the radiation and cold plate loads are in the range of 25% to 75% of peak loads. If all loads fall to zero, except the cabin air system which was fixed, the radiator fluid will drop below -100 F and may cause excessive pressure drop. If all loads reach 100%, the cabin air temperature could rise to 96 F.

  15. Corrosion-Control (CC) Program: Pilot Powder Coating Station Service Test.

    Science.gov (United States)

    1986-03-14

    8282, 1803M, 20 August 1985. 3-5 COMNAVSEASYSCOM Ltr. 9630, Ser . 05M1.14/374, 12 September 1985. 3-6 American Society for Testing and Materials (ASTM...Searchlights Vent Screens Miscellaneous Oil Spill Control Boxes Control Box Totl Cmpoent Poder Coated =68 Total Components Powder Coated =138 HORN (CG30

  16. Cryogenic Tests of 30 m Flexible Hybrid Energy Transfer Line with Liquid Hydrogen and Superconducting MgB2 Cable

    Science.gov (United States)

    Vysotsky, V. S.; Antyukhov, I. V.; Firsov, V. P.; Blagov, E. V.; Kostyuk, V. V.; Nosov, A. A.; Fetisov, S. S.; Zanegin, S. Yu.; Rachuk, V. S.; Katorgin, B. I.

    Recently we reported about first in the world test of 10 m hybrid energy transfer line with liquid hydrogen and MgB2 superconducting cable. In this paper we present the new development of our second hybrid energy transfer line with 30 m length. The flexible 30 m hydrogen cryostat has three sections with different types of thermal insulation in each section: simple vacuum superinsulation, vacuum superinsulation with liquid nitrogen shield and active evaporating cryostatting (AEC) system. We performed thermo-hydraulic tests of the cryostat to compare three thermo-insulating methods. The tests were performed at temperatures from 20 to 26 K, hydrogen flow from 100 to 450 g/s and pressure from 0.25 to 0.5 MPa. It was found that AEC thermal insulation practically eliminated completely heat transfer from room temperature to liquid hydrogen in the 10 m section. AEC thermal insulation method can be used for long superconducting power cables. High voltage current leads were developed as well. The current leads and superconducting MgB2 cable have been passed high voltage DC test up to 50 kV DC. Critical current of the cable at ∼21 K was ∼3500 A. The 30 m hybrid energy system developed is able to deliver up to 135 MW of chemical and electrical power in total.

  17. Using test station and on-farm data for the genetic evaluation of Pietrain boars used on Landrace sows for growth performance.

    Science.gov (United States)

    Dufrasne, M; Rustin, M; Jaspart, V; Wavreile, J; Gengler, N

    2011-12-01

    The aim of this study was to develop a new genetic evaluation model to estimate the genetic merit of boars for growth based on 1) performance of their crossbred progeny fattened in the test station and 2) their own performance or those of relatives from the on-farm testing system. The model was a bivariate random regression animal model with linear splines and was applied to Piétrain boars from the Walloon Region of Belgium mated with Landrace sows. Data contained 1) 12,610 BW records from the test station collected on 1,435 crossbred pigs from Piétrain boars and Landrace sows, and 2) 52,993 BW records from the on-farm testing system collected on 50,670 pigs with a breed composition of at least 40% Piétrain or Landrace. Since 2007, 56 Piétrain boars have been tested in the station. Data used to estimate variance components and breeding values were standardized for the age to take into account heterogeneity of variances and then pre-adjusted at 210 d of age to put all records on the same scale. Body weight records from the test station and from the on-farm testing system were considered as 2 different traits. The heterosis effect was modeled as fixed regression on the heterozygosity coefficient. As all test station animals were similarly crossbred, smaller variation in heterozygosity caused the sampling error of the regression estimate at 210 d to be larger in the test station than in on-farm data with estimates of 28.35 ± 14.55 kg and 9.02 ± 0.67 kg, respectively. Therefore, the most likely reason for the large differences in estimates was sampling. Heritability estimates ranged from 0.37 to 0.60 at 210 and 75 d, respectively, for test station BW and from 0.42 to 0.60 at 210 d and 175 d, respectively, for on-farm BW. Genetic correlation decreased when the age interval between records increased, and were greater between ages for test station than for on-farm data. Genetic correlations between test station and on-farm BW at the same age were high: 0.90 at 175 d

  18. Crack Growth Testing of an Aluminum Oxynitride (AlON) for International Space Station Kick Panes

    Science.gov (United States)

    Salem, Jonathan A.

    2017-01-01

    The mechanical properties of an aluminum oxynitride supplied as ground beams and disks were measured using ASTM International (formerly American Society for Testing and Materials) standard test methods. The slow crack growth tests were complicated by a "short" finish that increased strength scatter. Refining of the finish by more material removal in the second stage of grinding or the use of uniaxial grinding as specified in ASTM C1499 might have avoided the issue. The structural design parameters are an elastic modulus of E = 319 GPa, Poisson's ratio of v = 0.26, a fracture toughness of KIvb(A) = 2.18 MPa/m, slow crack growth (SCG) parameter n = 36, and SCG parameter A = 1.96 x 10-11 m/s.(MPa/m)n. For a ground finish, the Weibull parameters are a mean modulus of m = 14.0 and characteristic strength of ?sigma theta = 250.2 MPa. The 2015 vintage material exhibits similar mechanical properties to a 2010 vintage billet. Indentation flaws were not sensitive to the inherent crack growth mechanisms of this material and produced misleading results.

  19. Status of the SOS-LUX-Toxicity-Test on the International Space Station

    Science.gov (United States)

    Rabbow, E.; Rettberg, Petra; Baumstark-Khan, Christa; Schulze-Varnholt, Dirk; Franz, Markus; Reitz, Gunther

    2005-08-01

    For the safety of astronauts and to ensure stability and integrity of the genome of microorganisms and plants used in bioregenerative life support systems it is important to improve our knowledge on the combined action of (space) radiation and microgravity. The SOS-LUX- Toxicity Test as part of the TRIPLE-LUX project (accepted for flight in Biolab in Columbus on ISS) will provide an estimation of the health risk resulting from exposure of astronauts to the radiation environment of space in microgravity. The project will (i) increase knowledge of biological/health threatening action of space radiation and enzymatic DNA repair, (ii) uncover cellular mechanisms of synergistic interaction of microgravity and space radiation, (iii) provide specified biosensors for spacecraft milieu examination and (iv) provide experimental data on stability and integrity of bacterial DNA in spacecrafts. In the bacterial biosensor "SOS-LUX-Test" developed at DLR (patent), bacteria are transformed with the pBR322- derived plasmid pPLS-1 or the similar advanced plasmid Switch, both carrying the promoterless lux operon of Photobacterium leiognathi as reporter element controlled by a DNA-damage dependent SOS promoter as sensor element. A short description of the space experiment and first results of tests with the bread board model of the automated space hardware under development are given.

  20. Steam Oxidation of FeCrAl and SiC in the Severe Accident Test Station (SATS)

    Energy Technology Data Exchange (ETDEWEB)

    Pint, Bruce A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Unocic, Kinga A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Terrani, Kurt A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-08-01

    Numerous research projects are directed towards developing accident tolerant fuel (ATF) concepts that will enhance safety margins in light water reactors (LWR) during severe accident scenarios. In the U.S. program, the high temperature steam oxidation performance of ATF solutions has been evaluated in the Severe Accident Test Station (SATS) at Oak Ridge National Laboratory (ORNL) since 2012 [1-3] and this facility continues to support those efforts in the ATF community. Compared to the current UO2/Zr-based alloy fuel system, alternative cladding materials can offer slower oxidation kinetics and a smaller enthalpy of oxidation that can significantly reduce the rate of heat and hydrogen generation in the core during a coolant-limited severe accident [4-5]. Thus, steam oxidation behavior is a key aspect of the evaluation of ATF concepts. This report summarizes recent work to measure steam oxidation kinetics of FeCrAl and SiC specimens in the SATS.

  1. Flexible Flatfoot

    Science.gov (United States)

    ... this page. Please enable Javascript in your browser. Flexible Flatfoot What Is Flatfoot? Flatfoot is often a ... may develop as a result of a flatfoot. Flexible Flatfoot Flexible flatfoot is one of the most ...

  2. Development and qualification of a thermal-hydraulic nodalization for modeling station blackout accident in PSB-VVER test facility

    Energy Technology Data Exchange (ETDEWEB)

    Saghafi, Mahdi [Department of Energy Engineering, Sharif University of Technology, Azadi Avenue, Tehran (Iran, Islamic Republic of); Ghofrani, Mohammad Bagher, E-mail: ghofrani@sharif.edu [Department of Energy Engineering, Sharif University of Technology, Azadi Avenue, Tehran (Iran, Islamic Republic of); D’Auria, Francesco [San Piero a Grado Nuclear Research Group (GRNSPG), University of Pisa, Via Livornese 1291, San Piero a Grado, Pisa (Italy)

    2016-07-15

    Highlights: • A thermal-hydraulic nodalization for PSB-VVER test facility has been developed. • Station blackout accident is modeled with the developed nodalization in MELCOR code. • The developed nodalization is qualified at both steady state and transient levels. • MELCOR predictions are qualitatively and quantitatively in acceptable range. • Fast Fourier Transform Base Method is used to quantify accuracy of code predictions. - Abstract: This paper deals with the development of a qualified thermal-hydraulic nodalization for modeling Station Black-Out (SBO) accident in PSB-VVER Integral Test Facility (ITF). This study has been performed in the framework of a research project, aiming to develop an appropriate accident management support tool for Bushehr nuclear power plant. In this regard, a nodalization has been developed for thermal-hydraulic modeling of the PSB-VVER ITF by MELCOR integrated code. The nodalization is qualitatively and quantitatively qualified at both steady-state and transient levels. The accuracy of the MELCOR predictions is quantified in the transient level using the Fast Fourier Transform Base Method (FFTBM). FFTBM provides an integral representation for quantification of the code accuracy in the frequency domain. It was observed that MELCOR predictions are qualitatively and quantitatively in the acceptable range. In addition, the influence of different nodalizations on MELCOR predictions was evaluated and quantified using FFTBM by developing 8 sensitivity cases with different numbers of control volumes and heat structures in the core region and steam generator U-tubes. The most appropriate case, which provided results with minimum deviations from the experimental data, was then considered as the qualified nodalization for analysis of SBO accident in the PSB-VVER ITF. This qualified nodalization can be used for modeling of VVER-1000 nuclear power plants when performing SBO accident analysis by MELCOR code.

  3. Performance Testing of a Russian Mir Space Station Trace Contaminant Control Assembly

    Science.gov (United States)

    Curtis, R. E.; Perry, J. L.; Abramov, L. H.

    1997-01-01

    A filter assembly which is incorporated into the Russian Trace Contaminant Control Assembly was tested for removal of airborne trace chemical contaminants in a closed loop 9 m(exp 3) system. Given contaminant loading rates and maximum allowable atmospheric concentrations, the Russian system was able to maintain system air concentrations below maximum allowable limits. This was achieved for both a new filter system and for a system where a part of it was pre-loaded to emulate 3 years of system age.

  4. Developing a More Flexible Operational Test and Evaluation Process for Information Technology

    Science.gov (United States)

    2010-02-17

    Information technology (IT) is ubiquitous in the modern battlespace, existing as standalone programs and embedded in almost every weapons system. Its importance to the warfighter cannot be overstated. That being said, there is a serious disconnect between the current acquisition and testing approach for IT systems and the speed at which they develop. This disconnect is partially due to the Air Force using the same acquisition approach for IT systems as it does for every other major acquisition program. That approach was originally designed for large, relatively static,

  5. Captive chimpanzee foraging in a social setting: a test of problem solving, flexibility, and spatial discounting

    Directory of Open Access Journals (Sweden)

    Lydia M. Hopper

    2015-03-01

    Full Text Available In the wild, primates are selective over the routes that they take when foraging and seek out preferred or ephemeral food. Given this, we tested how a group of captive chimpanzees weighed the relative benefits and costs of foraging for food in their environment when a less-preferred food could be obtained with less effort than a more-preferred food. In this study, a social group of six zoo-housed chimpanzees (Pan troglodytes could collect PVC tokens and exchange them with researchers for food rewards at one of two locations. Food preference tests had revealed that, for these chimpanzees, grapes were a highly-preferred food while carrot pieces were a less-preferred food. The chimpanzees were tested in three phases, each comprised of 30 thirty-minute sessions. In phases 1 and 3, if the chimpanzees exchanged a token at the location they collected them they received a carrot piece (no travel or they could travel ≥10 m to exchange tokens for grapes at a second location. In phase 2, the chimpanzees had to travel for both rewards (≥10 m for carrot pieces, ≥15 m for grapes. The chimpanzees learned how to exchange tokens for food rewards, but there was individual variation in the time it took for them to make their first exchange and to discover the different exchange locations. Once all the chimpanzees were proficient at exchanging tokens, they exchanged more tokens for grapes (phase 3. However, when travel was required for both rewards (phase 2, the chimpanzees were less likely to work for either reward. Aside from the alpha male, all chimpanzees exchanged tokens for both reward types, demonstrating their ability to explore the available options. Contrary to our predictions, low-ranked individuals made more exchanges than high-ranked individuals, most likely because, in this protocol, chimpanzees could not monopolize the tokens or access to exchange locations. Although the chimpanzees showed a preference for exchanging tokens for their more

  6. High SO{sub 2} removal efficiency testing: Results of DBA and sodium formate additive tests at Southwestern Electric Power company`s Pirkey Station

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-05-30

    Tests were conducted at Southwestern Electric Power Company`s (SWEPCo) Henry W. Pirkey Station wet limestone flue gas desulfurization (FGD) system to evaluate options for achieving high sulfur dioxide removal efficiency. The Pirkey FGD system includes four absorber modules, each with dual slurry recirculation loops and with a perforated plate tray in the upper loop. The options tested involved the use of dibasic acid (DBA) or sodium formate as a performance additive. The effectiveness of other potential options was simulated with the Electric Power Research Institute`s (EPRI) FGD PRocess Integration and Simulation Model (FGDPRISM) after it was calibrated to the system. An economic analysis was done to determine the cost effectiveness of the high-efficiency options. Results are-summarized below.

  7. Testing the sampling efficiency of a nuclear power station stack monitor

    Energy Technology Data Exchange (ETDEWEB)

    Stroem, L.H. [Instrumentinvest, Nykoeping (Sweden)

    1997-08-01

    The test method comprises the injection of known amounts of monodisperse particles in the stack air stream, at a suitable point upstream of the sampling installation. To find a suitable injection polls, the gas flow was mapped by means of a tracer gas, released in various points in the stack base. The resulting concentration distributions at the stack sampler level were observed by means of an array of gas detectors. An injection point that produced symmetrical distribution over the stack area, and low concentrations at the stack walls was selected for the particle tests. Monodisperse particles of 6, 10, and 19 {mu}m aerodynamic diameter, tagged with dysprosium, were dispersed in the selected injection point. Particle concentration at the sampler level was measured. The losses to the stack walls were found to be less than 10 %. The particle concentrations at the four sampler inlets were calculated from the observed gas distribution. The amount calculated to be aspirated into the sampler piping was compared with the quantity collected by the sampling train ordinary filter, to obtain the sampling line transmission efficiency. 1 ref., 2 figs.

  8. Prototype Software for Future Spaceflight Tested at Mars Desert Research Station

    Science.gov (United States)

    Clancey, William J.; Sierhuis, Maaretn; Alena, Rick; Dowding, John; Garry, Brent; Scott, Mike; Tompkins, Paul; vanHoof, Ron; Verma, Vandi

    2006-01-01

    NASA scientists in MDRS Crew 49 (April 23-May 7, 2006) field tested and significantly extended a prototype monitoring and advising system that integrates power system telemetry with a voice commanding interface. A distributed, wireless network of functionally specialized agents interacted with the crew to provide alerts (e.g., impending shut-down of inverter due to low battery voltage), access md interpret historical data, and display troubleshooting procedures. In practical application during two weeks, the system generated speech over loudspeakers and headsets lo alert the crew about the need to investigate power system problems. The prototype system adapts the Brahms/Mobile Agents toolkit to receive data from the OneMeter (Brand Electronics) electric metering system deployed by Crew 47. A computer on the upper deck was connected to loudspeakers, four others were paired with wireless (Bluetooth) headsets that enabled crew members to interact with their personal agents from anywhere in the hab. Voice commands and inquiries included: 1. What is the {battery | generator} {volts | amps | volts and amps}? 2. What is the status of the {generator | inverter | battery | solar panel}? 3. What is the hab{itat} {power usage | volts | voltage | amps | volts and amps}? 4. What was the average hab{itat} {amps | volts | voltage} since {AM | PM)? 5. When did the {generator | batteries} change status? 6. Tell {me I | everyone} when{ ever} the generator goes offline. 7. Tell {me | | everyone} when the hab{itat} {amps | volts | voltage} {exceeds | drops brelow} . 8. {Send | Take | Record} {a} voice note {(for | to} } {at }. This research demonstrates the principles of design in the context of use, investigating requirements through experimental use of prototype systems in an analog setting, and use of MDRS as a research facility for designing and implementing new systems.

  9. Mechanical design, analysis, and laboratory testing of a dental implant with axial flexibility similar to natural tooth with periodontal ligament.

    Science.gov (United States)

    Pektaş, Ömer; Tönük, Ergin

    2014-11-01

    At the interface between the jawbone and the roots of natural teeth, a thin, elastic, shock-absorbing tissue, called the periodontal ligament, forms a cushion which provides certain flexibility under mechanical loading. The dental restorations supported by implants, however, involve comparatively rigid connections to the jawbone. This causes overloading of the implant while bearing functional loading together with neighboring natural teeth, which leads to high stresses within the implant system and in the jawbone. A dental implant, with resilient components in the upper structure (abutment) in order to mimic the mechanical behavior of the periodontal ligament in the axial direction, was designed, analyzed in silico, and produced for mechanical testing. The aims of the design were avoiding high levels of stress, loosening of the abutment connection screw, and soft tissue irritations. The finite element analysis of the designed implant revealed that the elastic abutment yielded a similar axial mobility with the natural tooth while keeping stress in the implant at safe levels. The in vitro mechanical testing of the prototype resulted in similar axial mobility predicted by the analysis and as that of a typical natural tooth. The abutment screw did not loosen under repeated loading and there was no static or fatigue failure.

  10. A Continuous-Adaptive DDRx Interface with Flexible Round-Trip-Time and Full Self Loop-Backed AC Test

    Science.gov (United States)

    Haraguchi, Masaru; Osawa, Tokuya; Yamazaki, Akira; Morishima, Chikayoshi; Morihara, Toshinori; Morooka, Yoshikazu; Okuno, Yoshihiro; Arimoto, Kazutami

    This paper describes new DDRx SDRAM interface architecture suitable for system-on-chip (SOC) implementation. Our test chip fabricated in a 90-nm CMOS process adopts three key schemes and achieves 960 Mb/s/pin operations with 32 bits width. One of new schemes is to suppress timing skew with rising-edge signal transmission I/O circuit and look-up table type impedance calibration circuit. DQS round-trip-time, propagation delay from rising edge of system clock in SOC to arrival of DQS at input PAD of SOC during read operation, becomes longer than one clock cycle time as for DDR2 interface and beyond. Flexible DQS round-trip-time scheme can allow wide range up to N/2 cycles in N bits burst read operation. In addition, full self loop-backed test scheme is also proposed to measure AC timing parameters without high-end tester. The architecture reported in this paper can be continuously adaptive to realize higher data-rate and cost-efficient DDRx-SDRAM interface for various kinds of SOC.

  11. Design and Fabrication of a Differential Electrostatic Accelerometer for Space-Station Testing of the Equivalence Principle.

    Science.gov (United States)

    Han, Fengtian; Liu, Tianyi; Li, Linlin; Wu, Qiuping

    2016-08-10

    The differential electrostatic space accelerometer is an equivalence principle (EP) experiment instrument proposed to operate onboard China's space station in the 2020s. It is designed to compare the spin-spin interaction between two rotating extended bodies and the Earth to a precision of 10(-12), which is five orders of magnitude better than terrestrial experiment results to date. To achieve the targeted test accuracy, the sensitive space accelerometer will use the very soft space environment provided by a quasi-drag-free floating capsule and long-time observation of the free-fall mass motion for integration of the measurements over 20 orbits. In this work, we describe the design and capability of the differential accelerometer to test weak space acceleration. Modeling and simulation results of the electrostatic suspension and electrostatic motor are presented based on attainable space microgravity condition. Noise evaluation shows that the electrostatic actuation and residual non-gravitational acceleration are two major noise sources. The evaluated differential acceleration noise is 1.01 × 10(-9) m/s²/Hz(1/2) at the NEP signal frequency of 0.182 mHz, by neglecting small acceleration disturbances. The preliminary work on development of the first instrument prototype is introduced for on-ground technological assessments. This development has already confirmed several crucial fabrication processes and measurement techniques and it will open the way to the construction of the final differential space accelerometer.

  12. Design and Fabrication of a Differential Electrostatic Accelerometer for Space-Station Testing of the Equivalence Principle

    Directory of Open Access Journals (Sweden)

    Fengtian Han

    2016-08-01

    Full Text Available The differential electrostatic space accelerometer is an equivalence principle (EP experiment instrument proposed to operate onboard China’s space station in the 2020s. It is designed to compare the spin-spin interaction between two rotating extended bodies and the Earth to a precision of 10−12, which is five orders of magnitude better than terrestrial experiment results to date. To achieve the targeted test accuracy, the sensitive space accelerometer will use the very soft space environment provided by a quasi-drag-free floating capsule and long-time observation of the free-fall mass motion for integration of the measurements over 20 orbits. In this work, we describe the design and capability of the differential accelerometer to test weak space acceleration. Modeling and simulation results of the electrostatic suspension and electrostatic motor are presented based on attainable space microgravity condition. Noise evaluation shows that the electrostatic actuation and residual non-gravitational acceleration are two major noise sources. The evaluated differential acceleration noise is 1.01 × 10−9 m/s2/Hz1/2 at the NEP signal frequency of 0.182 mHz, by neglecting small acceleration disturbances. The preliminary work on development of the first instrument prototype is introduced for on-ground technological assessments. This development has already confirmed several crucial fabrication processes and measurement techniques and it will open the way to the construction of the final differential space accelerometer.

  13. Design and Fabrication of a Differential Electrostatic Accelerometer for Space-Station Testing of the Equivalence Principle

    Science.gov (United States)

    Han, Fengtian; Liu, Tianyi; Li, Linlin; Wu, Qiuping

    2016-01-01

    The differential electrostatic space accelerometer is an equivalence principle (EP) experiment instrument proposed to operate onboard China’s space station in the 2020s. It is designed to compare the spin-spin interaction between two rotating extended bodies and the Earth to a precision of 10−12, which is five orders of magnitude better than terrestrial experiment results to date. To achieve the targeted test accuracy, the sensitive space accelerometer will use the very soft space environment provided by a quasi-drag-free floating capsule and long-time observation of the free-fall mass motion for integration of the measurements over 20 orbits. In this work, we describe the design and capability of the differential accelerometer to test weak space acceleration. Modeling and simulation results of the electrostatic suspension and electrostatic motor are presented based on attainable space microgravity condition. Noise evaluation shows that the electrostatic actuation and residual non-gravitational acceleration are two major noise sources. The evaluated differential acceleration noise is 1.01 × 10−9 m/s2/Hz1/2 at the NEP signal frequency of 0.182 mHz, by neglecting small acceleration disturbances. The preliminary work on development of the first instrument prototype is introduced for on-ground technological assessments. This development has already confirmed several crucial fabrication processes and measurement techniques and it will open the way to the construction of the final differential space accelerometer. PMID:27517927

  14. Flexible supercapacitors

    Institute of Scientific and Technical Information of China (English)

    Shan Shi; Chengjun Xu; Cheng Yang; Jia Li; Hongda Du; Baohua Li; Feiyu Kang

    2013-01-01

    Flexible supercapacitors show a great potential for applications in wearable,miniaturized,portable,largescale transparent and flexible consumer electronics due to their significant,inherent advantages,such as being flexible,lightweight,low cost and environmentally friendly in comparison with the current energy storage devices.In this report,recent progress on flexible supercapacitors,flexible electrodes and electrolytes is reviewed.In addition,the future challenges and opportunities are discussed.

  15. Field Testing of Activated Carbon Injection Options for Mercury Control at TXU's Big Brown Station

    Energy Technology Data Exchange (ETDEWEB)

    John Pavlish; Jeffrey Thompson; Christopher Martin; Mark Musich; Lucinda Hamre

    2009-01-07

    The primary objective of the project was to evaluate the long-term feasibility of using activated carbon injection (ACI) options to effectively reduce mercury emissions from Texas electric generation plants in which a blend of lignite and subbituminous coal is fired. Field testing of ACI options was performed on one-quarter of Unit 2 at TXU's Big Brown Steam Electric Station. Unit 2 has a design output of 600 MW and burns a blend of 70% Texas Gulf Coast lignite and 30% subbituminous Powder River Basin coal. Big Brown employs a COHPAC configuration, i.e., high air-to-cloth baghouses following cold-side electrostatic precipitators (ESPs), for particulate control. When sorbent injection is added between the ESP and the baghouse, the combined technology is referred to as TOXECON{trademark} and is patented by the Electric Power Research Institute in the United States. Key benefits of the TOXECON configuration include better mass transfer characteristics of a fabric filter compared to an ESP for mercury capture and contamination of only a small percentage of the fly ash with AC. The field testing consisted of a baseline sampling period, a parametric screening of three sorbent injection options, and a month long test with a single mercury control technology. During the baseline sampling, native mercury removal was observed to be less than 10%. Parametric testing was conducted for three sorbent injection options: injection of standard AC alone; injection of an EERC sorbent enhancement additive, SEA4, with ACI; and injection of an EERC enhanced AC. Injection rates were determined for all of the options to achieve the minimum target of 55% mercury removal as well as for higher removals approaching 90%. Some of the higher injection rates were not sustainable because of increased differential pressure across the test baghouse module. After completion of the parametric testing, a month long test was conducted using the enhanced AC at a nominal rate of 1.5 lb/Macf. During

  16. Design and Testing of a 2-Hour Oxygen Prebreathe Protocol for Space Walks from the International Space Station

    Science.gov (United States)

    Gernhardt, Michael L.; Conkin, J.; Foster, P. P.; Pilmanis, A. A.; Butler, B. D.; Beltran, E.; Fife, C. E.; Vann, R. D.; Gerth, W. A.; Loftin, K. C.; hide

    2000-01-01

    To develop and test a 2-hour prebreathe protocol for performing extravehicular activities (EVAs) from the International Space Station (ISS). Combinations of adynamia (non-walking), prebreathe exercise, and space suit donning options (10.2 vs. 14.7 psi) were evaluated, against timeline and consumable contraints to develop an operational 2- hour prebreathe protocol. Prospective accept/reject criteria were defined for decompression sickness (DCS) and venous gas emboli (VGE) from analysis of historical DCS data, combined with risk management of DCS under ISS mission circumstances. Maximum operational DCS levels were defined based on protecting for EVA capability with two crew-members at 95% confidence, throughout ISS lifetime (within the constraints of NASA DCS disposition policy JPG 1800.3). The accept/reject limits were adjusted for greater safety based on analysis of related medical factors. Monte-Carlo simulation was performed to design a closed sequential, multi-center human trial. Protocols were tested with 4 different prebreathe exercises (Phases I-IV), prior to exposure to 4.3 psi for 4 hrs. Subject selection, Doppler monitoring for VGE, test termination criteria, and DCS definitions were standardized. Phase I: upper and lower body exercises using dual-cycle ergometry (75% VO2 max for 10 min). Phase II: ergometry plus 24 min of light exercise (simulating space-suit preparations). Phase III: same 24 min of light exercise but no ergometry, and Phase IV: 56 min of light exercise without ergometry. A prebreathe procedure was accepted if, at 95% confidence, the incidence of DCS was less than 15% (with no Type II DCS), and Grade IV VGE was less than 20%.

  17. Model test of the tunnel subjected to high water pressure in Jinping Second Cascade Hydropower Station,China

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    In the area with high groundwater pressure,grout curtain is often adopted to reduce the water pressure on tunnel lining.A series of model tests for the diversion tunnel of the Jinping Second Cascade Hydropower Station,China,is designed to study the effect of grout curtain.The impact of the thickness of grout curtain,permeability of grout curtain,internal water pressure and drainage inflow on the distribution of water pressure are discussed.The results indicates that under un-drained condition,water pressure is equal to hydrostatic one no matter grout curtain is selected or not,water pressure under drained condition is far less than that of un-drained condition,drainage in tunnel can reduce tunnel water pressure effectively.For same inflow,both increasing of thickness and decrease of hydraulic conductivity of grout curtain can reduce water pressure effectively.For the same water pressure,the smaller inflow of grout curtain,the less volume of water to be discharged.The impact of hydraulic conductivity of grout curtain is more obvious than that of thickness.With increasing of internal water pressure,the water pressure of grout curtain increases too,and the water pressure increases nearly linearly.The proposed thickness of grout curtain for the diversion tunnels is 16 m.

  18. Corrective Action Investigation Plan for Corrective Action Unit 321: Area 22 Weather Station Fuel Storage, Nevada Test Site, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    DOE/NV

    1999-01-28

    This Corrective Action Investigation Plan (CAIP) has been developed in accordance with the Federal Facility Agreement and Consent Order (FFACO) that was agreed to by the US Department of Energy, Nevada Operations Office (DOE/NV); the State of Nevada Division of Environmental Protection (NDEP); and the US Department of Defense (FFACO, 1996). The CAIP is a document that provides or references all of the specific information for investigation activities associated with Corrective Action Units (CAUs) or Corrective Action Sites (CASs). According to the FFACO (1996), CASs are sites potentially requiring corrective action(s) and may include solid waste management units or individual disposal or release sites. A CAU consists of one or more CASs grouped together based on geography, technical similarity, or agency responsibility for the purpose of determining corrective actions. This CAIP contains the environmental sample collection objectives and the criteria for conducting site investigation activities at the CAU 321 Area 22 Weather Station Fuel Storage, CAS 22-99-05 Fuel Storage Area. For purposes of this discussion, this site will be referred to as either CAU 321 or the Fuel Storage Area. The Fuel Storage Area is located in Area 22 of the Nevada Test Site (NTS). The NTS is approximately 105 kilometers (km) (65 miles [mi]) northwest of Las Vegas, Nevada (Figure 1-1) (DOE/NV, 1996a). The Fuel Storage Area (Figure 1-2) was used to store fuel and other petroleum products necessary for motorized operations at the historic Camp Desert Rock facility which was operational from 1951 to 1958 at the Nevada Test Site, Nevada. The site was dismantled after 1958 (DOE/NV, 1996a).

  19. Overview of Microbiological Tests Performed During the Design of the International Space Station Environmental Control and Life Support Systems

    Science.gov (United States)

    Roman, Monsi C.; Mittelman, Marc W.

    2010-01-01

    The design and manufacturing of the main Environmental Control and Life Support Systems (ECLSS) for the United States segments of the International Space Station (ISS) was an involved process that started in the late 1980's, with the assessment and testing of competing technologies that could be used to clean the air and recycle water. It culminated in 2009 with the delivery and successful activation of the Water Recovery System (WRS) water processor (WP). The ECLSS required the work of a team of engineers and scientist working together to develop systems that could clean and/or recycle human metabolic loads to maintain a clean atmosphere and provide the crew clean water. One of the main goals of the ECLSS is to minimize the time spent by the crew worrying about vital resources not available in the vacuum of space, which allows them to spend most of their time learning to live in a microgravity environment many miles from the comforts of Earth and working on science experiments. Microorganisms are a significant part of the human body as well as part of the environment that we live in. Therefore, the ISS ECLSS design had to take into account the effect microorganisms have on the quality of stored water and wastewater, as well as that of the air systems. Hardware performance issues impacted by the accumulation of biofilm and/or microbiologically influenced corrosion were also studied during the ECLSS development stages. Many of the tests that were performed had to take into account the unique aspects of a microgravity environment as well as the challenge of understanding how to design systems that could not be sterilized or maintained in a sterile state. This paper will summarize the work of several studies that were performed to assess the impacts and/or to minimize the effects of microorganisms in the design of a closed loop life support system.

  20. COMPARISON OF TWO TECHNIQUES MASSAGE; STATIC STRETCHING AND COMBINATION OF MASSAGE AND STRETCHING IN LOWER LIMB MUSCLE ON FLEXIBILITY; POWER AND AGILITY TESTS PERFORMANCE IN SOCCER PLAYERS

    OpenAIRE

    Ali Chourli; Hadi Rohani; Ali Mostafalou; Somaye Khosrojerdi

    2011-01-01

    The purpose of this study was investigating Comparison of two techniques massage; staticstretching and combination of massage and stretching in lower limb muscle on flexibility;power and agility tests performance in soccer players. 45 soccer players in three groupsrandomly massage (15 cases); stretching (15 cases) and a combination of massage andstretching group (15 cases) were selected; performed the Sit and Reach; Toe-Touch; VerticalJump and 4×9 tests in two stages before and after massage;...

  1. Evaluation of alpha7 nicotinic acetylcholine receptor agonists and positive allosteric modulators using the parallel oocyte electrophysiology test station.

    Science.gov (United States)

    Malysz, John; Grønlien, Jens H; Timmermann, Daniel B; Håkerud, Monika; Thorin-Hagene, Kirsten; Ween, Hilde; Trumbull, Jonathan D; Xiong, Yongli; Briggs, Clark A; Ahring, Philip K; Dyhring, Tino; Gopalakrishnan, Murali

    2009-08-01

    Neuronal acetylcholine receptors (nAChRs) of the alpha7 subtype are ligand-gated ion channels that are widely distributed throughout the central nervous system and considered as attractive targets for the treatment of various neuropsychiatric and neurodegenerative diseases. Both agonists and positive allosteric modulators (PAMs) are being developed as means to enhance the function of alpha7 nAChRs. The in vitro characterization of alpha7 ligands, including agonists and PAMs, relies on multiple technologies, but only electrophysiological measurements assess the channel activity directly. Traditional electrophysiological approaches utilizing two-electrode voltage clamp or patch clamp in isolated cells have very low throughput to significantly impact drug discovery. Abbott (Abbott Park, IL) has developed a two-electrode voltage clamp-based system, the Parallel Oocyte Electrophysiology Test Station (POETs()), that allows for the investigation of ligand-gated ion channels such as alpha7 nAChRs in a higher-throughput manner. We describe the utility of this technology in the discovery of selective alpha7 agonists and PAMs. With alpha7 agonists, POETs experiments involved both single- and multiple-point concentration-response testing revealing diverse activation profiles (zero efficacy desensitizing, partial, and full agonists). In the characterization of alpha7 PAMs, POETs testing has served as a reliable primary or secondary screen identifying compounds that fall into distinct functional types depending on the manner in which current potentiation occurred. Type I PAMs (eg, genistein, NS1738, and 5-hydroxyindole) increase predominantly the peak amplitude response, type II PAMs affect the peak current and current decay (eg, PNU-120,596 and 4-(naphthalen-1-yl)-3a,4,5,9b-tetrahydro-3H-cyclopenta[c]quinoline-8-sulfonamide), and anothertype slowing the current decay kinetics in the absence of increases in the peak current. In summary, POETs technology allows for significant

  2. Toxicity tests and sediment chemistry at Site 9 (Neptune Drive Disposal Site) - U.S. Naval Air Station, Brunswick, Maine

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — During a remedial investigation of the U.S. Naval Air Station Superfund Site in Brunswick, Maine (NASB), elevated concentrations of total polycyclic aromatic...

  3. Test des photomultiplicateurs en silicium couplés à un scintillateur plastique pour la nouvelle Tape Station

    CERN Document Server

    sekal, Smain

    2014-01-01

    L’une des parties essentielles de la l’installation ISOLDE est la tape Station (contrôleur de bandes), qui permet la vérification de la qualité du faisceau délivré aux expériences. On prévoit à ISOLDE de remplacer l’ancienne Tape Station, par une nouvelle Tape station; et l’un des paramètres essentiels pour la performance de la tape Station est l’efficacité de détection. Le but de ce travail est de vérifier l’efficacité des détecteurs de particules bêta, composés par l’association des photomultiplicateurs en Silicium à un scintillateur plastique pour differentes distances.

  4. Strategic flexibility

    OpenAIRE

    Kim, KiHyung

    2014-01-01

    A flexible system is defined as one that can change the entity's stance, capability or status reacting to a change of the entity's environment. Flexibility has gathered the attention of academic researchers and industry practitioners as an efficient approach to cope with today's volatile environment. As the environments become more unpredictable and volatile, it is imperative for a flexible system to respond quickly to a change in its circumstance. How much flexibility is embedded into the sy...

  5. Tests of a new CCD-camera based neutron radiography detector system at the reactor stations in Munich and Vienna

    Energy Technology Data Exchange (ETDEWEB)

    Lehmann, E.; Pleinert, H. [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Schillinger, B. [Technische Univ. Muenchen (Germany); Koerner, S. [Atominstitut der Oesterreichischen Universitaeten, Vienna (Austria)

    1997-09-01

    The performance of the new neutron radiography detector designed at PSI with a cooled high sensitive CCD-camera was investigated under real neutronic conditions at three beam ports of two reactor stations. Different converter screens were applied for which the sensitivity and the modulation transfer function (MTF) could be obtained. The results are very encouraging concerning the utilization of this detector system as standard tool at the radiography stations at the spallation source SINQ. (author) 3 figs., 5 refs.

  6. Flexible Ablators

    Science.gov (United States)

    Stackpoole, Margaret M. (Inventor); Ghandehari, Ehson M. (Inventor); Thornton, Jeremy J. (Inventor); Covington, Melmoth Alan (Inventor)

    2017-01-01

    A low-density article comprising a flexible substrate and a pyrolizable material impregnated therein, methods of preparing, and devices using the article are disclosed. The pyrolizable material pyrolizes above 350 C and does not flow at temperatures below the pyrolysis temperature. The low-density article remains flexible after impregnation and continues to remain flexible when the pyrolizable material is fully pyrolized.

  7. Genotoxicity testing on the international space station: Preparatory work on the SOS-LUX test as part of the space experiment TRIPLE-LUX

    Science.gov (United States)

    Stojicic, Nevena; Walrafen, David; Baumstark-Khan, Christa; Rabbow, Elke; Rettberg, Petra; Weisshaar, Maria-Paz; Horneck, Gerda

    Harmful environmental factors - namely ionizing radiation - will continue to influence future manned space missions. The Radiation Biology Unit at the German Aerospace Center (DLR) develops cellular monitoring systems, which include bacterial and mammalian cell systems capable of recognizing DNA damage as a consequence of the presence of genotoxic conditions. Such a bioassay is the SOS-LUX test, which represents the radiobiological part of the German space experiment "Gene, immune and cellular responses to single and combined space flight conditions (TRIPLE-LUX)" which has been selected by the IDI/USRA Peer Review Panel for NASA/ESA to be performed on the International Space Station (ISS). It will supply basic information on the genotoxic response to radiation applied in microgravity. The biological end-point under investigation will depend on the bacterial SOS response brought about by genetically modified bacteria that are transformed with the pSWITCH plasmid (constructed from the plasmids pPLS-1 and pGFPuv). The luminescent/fluorescent bioassay SWITCH (SWITCH: Salmonella Weighting of Induced Toxicity Cyto/GenoTox for Human Health) as successor of the SOS-LUX test for rapid toxicity (genotoxicity and cytotoxicity) testing, makes use of two sensing and reporting systems for the two biological endpoints under investigation: the SOS-LUX test and the LAC- Fluoro test. The SWITCH plasmid carries the promoterless lux operon of Photobacterium leiognathi as reporter element under the control of the DNA-damage-dependent SOS promoter of ColD as sensor element (for genotoxicity testing) and the sequences for a hybrid protein consisting of β-galactosidase and GFPuv of Aequorea victoria as reporter element under the control of the (in Salmonella constitutively active) LAC promoter of Escherichia coli as sensor element (for cytotoxicity testing). The system has worked properly for terrestrial applications during the first experiments. Experiments using X-rays and UV radiation

  8. Cost-effectiveness of population-based screening for colorectal cancer: a comparison of guaiac-based faecal occult blood testing, faecal immunochemical testing and flexible sigmoidoscopy.

    Science.gov (United States)

    Sharp, L; Tilson, L; Whyte, S; O'Ceilleachair, A; Walsh, C; Usher, C; Tappenden, P; Chilcott, J; Staines, A; Barry, M; Comber, H

    2012-02-28

    Several colorectal cancer-screening tests are available, but it is uncertain which provides the best balance of risks and benefits within a screening programme. We evaluated cost-effectiveness of a population-based screening programme in Ireland based on (i) biennial guaiac-based faecal occult blood testing (gFOBT) at ages 55-74, with reflex faecal immunochemical testing (FIT); (ii) biennial FIT at ages 55-74; and (iii) once-only flexible sigmoidoscopy (FSIG) at age 60. A state-transition model was used to estimate costs and outcomes for each screening scenario vs no screening. A third party payer perspective was adopted. Probabilistic sensitivity analyses were undertaken. All scenarios would be considered highly cost-effective compared with no screening. The lowest incremental cost-effectiveness ratio (ICER vs no screening euro 589 per quality-adjusted life-year (QALY) gained) was found for FSIG, followed by FIT euro 1696) and gFOBT (euro 4428); gFOBT was dominated. Compared with FSIG, FIT was associated with greater gains in QALYs and reductions in lifetime cancer incidence and mortality, but was more costly, required considerably more colonoscopies and resulted in more complications. Results were robust to variations in parameter estimates. Population-based screening based on FIT is expected to result in greater health gains than a policy of gFOBT (with reflex FIT) or once-only FSIG, but would require significantly more colonoscopy resources and result in more individuals experiencing adverse effects. Weighing these advantages and disadvantages presents a considerable challenge to policy makers.

  9. Flexible sigmoidoscopy following a positive faecal occult blood test within a bowel screening programme may reduce the detection of neoplasia.

    Science.gov (United States)

    Mansouri, D; McMillan, D C; Roxburgh, C S D; Moug, S J; Crighton, E M; Horgan, P G

    2013-11-01

    Colorectal cancer screening using the faecal occult blood test (FOBt) detects a disproportionate number of left-sided tumours. This study aims to examine the theoretical impact on neoplasia detection rates of a sigmoidoscopy-first protocol in FOBt-positive patients undergoing colonoscopy. From retrieved endoscopy/pathology reports, pathology up to and including the splenic flexure was assumed detectable by sigmoidoscopy. High-risk polyps prompting subsequent colonoscopy were classed as three or more polyps, one polyp of ≥ 1 cm, villous or tubulovillous components or the presence of high-grade dysplasia. Between April 2009 and April 2011, 4631 patients underwent colonoscopy as a result of a positive FOBt in Greater Glasgow and Clyde. Cancer was detected in 398 (9%) and adenomas were detected in 1985 (47%) of which 1323 (67%) were deemed significant according to British Society of Gastroenterology guidelines. Applying the flexible sigmoidoscopy-first model, cancer would have been detected in 329 (8%) patients and adenomas in 1640 (39%), of which 1140 (70%) would have been significant. In total, 1546 (37%) patients would have required subsequent colonoscopy, following which 21 patients would have a new diagnosis of cancer. The positive predictive values (PPVs) for neoplasia (47 vs 57%, P < 0.001), significant neoplasia (35 vs 41%, P < 0.001) and cancer (8 vs 9%, P = 0.007) were all lower in the sigmoidoscopy-first model. A significant reduction in the detection of both adenomas and cancers would be seen if the sigmoidoscopy-first protocol were to be used following a positive FOBt. Furthermore, a significant proportion of patients would be subjected to two procedures, with considerable implications for both the patient and cost. Colorectal Disease © 2013 The Association of Coloproctology of Great Britain and Ireland.

  10. Gas recovery and self-testing systm in gasoline stations. Execution of practical field tests / phase of tests in the wholistic system; Gasrueckfuehrung und selbstueberwachende Systeme an Tankstellen. Durchfuehrung von praktischen Feldtests/Testphase im ganzheitlichen System

    Energy Technology Data Exchange (ETDEWEB)

    Altmann, B.R.; Kunter, S.; Maurer, C.; Schneider, T.; Schrittenlacher, W.; Maahsen, H.; Arts, M.

    2003-04-01

    The amendment of the 21{sup st} Regulation on Air-Pollution Control dated 17.05.2002 describes continuous control of the function of gas recovery systems in gasoline stations by automatic control systems. Both systems available in the market (supplied by FAFNIR and TOKHEIM) were tested in extensive field tests. Both systems are ready for mass production. New dispensers are delivered with self control systems per production-type since 1.04.2003. Supplementary kits for the different dispenser types are available. (orig.)

  11. Flexible Software for Flexible Scheduling

    Science.gov (United States)

    Economou, Frossie; Jenness, Tim; Tilanus, Remo P. J.; Hirst, Paul; Adamson, Andy J.; Rippa, Mathew; Delorey, Kynan K.; Isaak, Kate G.

    The JAC Observation Management Project (OMP) provides software for the James Clerk Maxwell (JCMT) and the United Kingdom Infrared (UKIRT) telescopes that manages the life-cycle of flexibly scheduled observations. Its aim is to increase observatory efficiency under flexible (queue) scheduled observing, without depriving the principal investigator (PI) of the flexibility associated with classical scheduling.

  12. Waste Transfer Stations

    DEFF Research Database (Denmark)

    Christensen, Thomas Højlund

    2011-01-01

    tion and transport is usually the most costly part of any waste management system; and when waste is transported over a considerable distance or for a long time, transferring the waste from the collection vehicles to more efficient transportation may be economically beneficial. This involves...... a transfer station where the transfer takes place. These stations may also be accessible by private people, offering flexibility to the waste system, including facilities for bulky waste, household hazardous waste and recyclables. Waste transfer may also take place on the collection route from small...... satellite collection vehicles to large compacting vehicles that cannot effectively travel small streets and alleys within the inner city or in residential communities with narrow roads. However, mobile transfer is not dealt with in this chapter, which focuses on stationary transfer stations. This chapter...

  13. 新型柔性浮式防波堤的水动力试验研究%Hydrodynamic Testing and Research of New Flexible Floating Breakwater

    Institute of Scientific and Technical Information of China (English)

    汪宏; 徐洪彬; 宣刚

    2013-01-01

    重点介绍新型浮式柔性防波堤的结构特点,通过室内物理模型试验获得在规则波作用下柔性浮式防波堤的透射系数,探讨波浪周期、波高和堤身宽度等因素对新型柔性浮式防波堤消波性能的影响。相关研究结果表明,新型柔性浮式防波堤对长周期波和短周期波均有较好的消减作用,其消波性能比传统防波堤更优越。%The structural characteristics of new flexible floating breakwater are introduced as key points. Indoor physical model test is made in order to get the transmission coefficient of the flexible floating breakwater under regular wave, discuss the influence of wave period, wave height and breakwater width on wave dissipation performance of new flexible floating breakwater. The research result shows that new flexible floating breakwater is of better wave dissipation performance than traditional breakwater,the former is able to decrease long-period wave and short-period wave effectively.

  14. Cost-effective monitoring of land subsidence in developing countries using semipermanent GPS stations: a test study over Houston, Texas

    Science.gov (United States)

    Kim, Donghwan; Lee, Hyongki; Okeowo, Modurodoluwa A.; Basnayake, Senaka; Jayasinghe, Susantha

    2017-04-01

    We present a cost-effective method for monitoring land subsidence in developing countries using measurements from semipermanent global positioning system (GPS) stations and interferometric synthetic aperture radar (InSAR) observations. The cost of maintaining a network of permanent GPS stations to monitor subsidence in developing countries might be implausible due to the high cost of maintenance. Hence, semipermanent GPS stations could be an alternative method, which densifies a GPS network with relatively inexpensive costs. We used three statistical methods to estimate the subsidence. We investigated the optimum time intervals for semipermanent GPS measurements based on the similarities of subsidence magnitudes and curve patterns with the permanent GPS measurements. In addition, we assessed the open source GPS processing tools based on the data quality of different session durations. Among the three models, the smoothing spline model showed the best estimation of subsidence. Among the different time interval data, 10- or 30-day time interval data were optimum for semipermanent GPS stations. Finally, we compared the GPS results to the InSAR-derived subsidence result, and both methods show that the northwestern Houston area subsides by about 1.5 to 2.0 cm/year. We anticipate that our method can be applied to other cities experiencing subsidence in developing countries.

  15. Station Capacity

    DEFF Research Database (Denmark)

    Landex, Alex

    2011-01-01

    Stations are often limiting the capacity of railway networks. This is due to extra need of tracks when trains stand still, trains turning around, and conflicting train routes. Although stations are often the capacity bottlenecks, most capacity analysis methods focus on open line capacity. Therefore......, this paper presents methods to analyze station capacity. Four methods to analyze station capacity are developed. The first method is an adapted UIC 406 capacity method that can be used to analyze switch zones and platform tracks at stations that are not too complex. The second method examines the need...... the probability of conflicts and the minimum headway times into account. The last method analyzes how optimal platform tracks are used by examining the arrival and departure pattern of the trains. The developed methods can either be used separately to analyze specific characteristics of the capacity of a station...

  16. Space Station

    Science.gov (United States)

    Anderton, D. A.

    1985-01-01

    The official start of a bold new space program, essential to maintain the United States' leadership in space was signaled by a Presidential directive to move aggressively again into space by proceeding with the development of a space station. Development concepts for a permanently manned space station are discussed. Reasons for establishing an inhabited space station are given. Cost estimates and timetables are also cited.

  17. Flexible Carbon Aerogels

    Directory of Open Access Journals (Sweden)

    Marina Schwan

    2016-09-01

    Full Text Available Carbon aerogels are highly porous materials with a large inner surface area. Due to their high electrical conductivity they are excellent electrode materials in supercapacitors. Their brittleness, however, imposes certain limitations in terms of applicability. In that context, novel carbon aerogels with varying degree of flexibility have been developed. These highly porous, light aerogels are characterized by a high surface area and possess pore structures in the micrometer range, allowing for a reversible deformation of the aerogel network. A high ratio of pore size to particle size was found to be crucial for high flexibility. For dynamic microstructural analysis, compression tests were performed in-situ within a scanning electron microscope allowing us to directly visualize the microstructural flexibility of an aerogel. The flexible carbon aerogels were found to withstand between 15% and 30% of uniaxial compression in a reversible fashion. These findings might stimulate further research and new application fields directed towards flexible supercapacitors and batteries.

  18. Conflicting flexibility

    NARCIS (Netherlands)

    De Jong, P.; Schaap, A.

    2011-01-01

    New buildings are designed for first users. For a sustainable approach there are many advantages in designing in flexibility and adjustability in order to enable and facilitate the other sequential users. For the first investor this flexibility is translated into improved exit values due to

  19. Application of the Trail Making Test in the assessment of cognitive flexibility in patients with speech disorders after ischaemic cerebral stroke

    Directory of Open Access Journals (Sweden)

    Anna Rajtar-Zembaty

    2015-04-01

    Full Text Available The main aim of this study was to evaluate the level of cognitive flexibility in patients with speech disorders after ischaemic cerebral stroke. The study was conducted in a group of 43 patients (18 women and 25 men who had experienced cerebral ischaemic stroke. The patients under study were divided into groups based on the type of speech disorders, i.e.: aphasia, lack of speech disorders and dysarthria. A Mini-Mental State Examination (MMSE and a Clock Drawing Test (CDT were applied for the general evaluation of the efficiency of cognitive functions. Cognitive flexibility – a component of executive functions, was evaluated with the use of a Trail Making Test (TMT. The results obtained prove that patients with aphasia show the lowest level of cognitive flexibility. Disorders of executive functions can be related to the dysfunction of the prefrontal cortex which has been damaged as a result of ischaemic cerebral stroke. Presumably, there are common functional neuroanatomical circuits for both language skills and components of executive functions. In the case of damage to the structures that are of key importance for both skills, language and executive dysfunctions can therefore occur in parallel. The presence of executive dysfunctions in patients with aphasia can additionally impede the functioning of the patient, and also negatively influence the process of rehabilitation the aim of which is to improve the efficiency of communication.

  20. Field testing of behavioral barriers for fish exclusion at cooling-water intake systems, Central Hudson Gas and Electric Company Roseton Generating Station: Final report

    Energy Technology Data Exchange (ETDEWEB)

    Matousek, J.A.; Wells, A.W.; McGroddy, P.M.

    1988-09-01

    A seasonal field testing program was conducted during 1986 and 1987 to evaluate the effectiveness of behavioral barriers at Central Hudson Gas and Electric Corporations's Roseton Generating Station located in the euryhaline section of the Hudson River. This station was selected as representative of power plants with shoreline riverine/estuarine intake systems. Three commercially available devices (air bubble curtain, pneumatic gun, and underwater strobe light) were tested alone and in combination to determine their effectiveness in reducing impingement. The primary testing method incorporated three or four 6-h impingement collections during each test date, each consisting of two randomly assigned 3-h samples: one was an experimental test with a behavioral device in operation, the other a control test with no device operating. The effectiveness of the devices at excluding fish was determined by comparing impingement data from experimental and control periods. Results of the program do not establish that the deployment of underwater strobe lights, pneumatic guns, an air bubble curtain, or various combinations of the three devices will effectively lower fish impingement at power plants similar in design and location to the Roseton plant. Deterrent effectiveness was found to be species-specific and related to time of day. 51 refs., 67 figs., 72 tabs.

  1. A Test Facility for the International Linear Collider at SLAC End Station A, for Prototypes of Beam Delivery and IR Components

    CERN Document Server

    Woods, Mike; Arnold, Ray; Bailey, D; Barlow, Roger J; Beard, Carl D; Boogert, Stewart Takashi; Burrows, P N; Burton, D; Christian, Glenn B; Clarke, Christine; Cussans, D; Densham, C; Erickson, Roger; Frisch, Josef; Greenhalgh, J; Hartin, Anthony F; Hast, Carsten; Hildreth, Michael; Jackson, Frank; Kalinin, Alexander; Jobe, R Keith; Keller, Lewis; Kolomensky, Yury; Kourevlev, German Yu; Lyapin, A; Malton, Stephen; Markiewicz, Thomas W; Maruyama, Takashi; McCormick, Douglas; Mercer, Adam; Miller, David J; Molloy, Stephen; Nelson, Janice; Phinney, Nan; Raubenheimer, Tor O; Ross, Marc; Seryi, Andrei; Shales, N; Sinev, N; Slater, Mark; Smith, J; Smith, Stephen; Sopczak, A; Sugimoto, Y; Szalata, Zen M; Tenenbaum, P G; Thomson, Mark; Torrence, Eric; Tucker, R W; Walston, Sean; Ward, David; Watson, Nigel; Weiland, Thomas; White, Glen; Wing, Matthew; Woodley, Mark; Zagorodnov, Igor; Zimmermann, Frank

    2005-01-01

    The SLAC Linac can deliver damped bunches with ILC parameters for bunch charge and bunch length to End Station A. A 10Hz beam at 28.5 GeV energy can be delivered there, parasitic with PEP-II operation. We plan to use this facility to test prototype components of the Beam Delivery System and Interaction Region. We discuss our plans for this ILC Test Facility and preparations for carrying out experiments related to collimator wakefields and energy spectrometers. We also plan an interaction region mockup to investigate effects from backgrounds and beam-induced electromagnetic interference.

  2. Station Capacity

    DEFF Research Database (Denmark)

    Landex, Alex

    2011-01-01

    Stations are often limiting the capacity of railway networks. This is due to extra need of tracks when trains stand still, trains turning around, and conflicting train routes. Although stations are often the capacity bottlenecks, most capacity analysis methods focus on open line capacity. Therefore......, this paper presents methods to analyze station capacity. Four methods to analyze station capacity are developed. The first method is an adapted UIC 406 capacity method that can be used to analyze switch zones and platform tracks at stations that are not too complex. The second method examines the need...... for platform tracks and the probability that arriving trains will not get a platform track immediately at arrival. The third method is a scalable method that analyzes the conflicts in the switch zone(s). In its simplest stage, the method just analyzes the track layout while the more advanced stages also take...

  3. Hydroxyapatite Nanowires@Metal-Organic Framework Core/Shell Nanofibers: Templated Synthesis, Peroxidase-Like Activity, and Derived Flexible Recyclable Test Paper.

    Science.gov (United States)

    Chen, Fei-Fei; Zhu, Ying-Jie; Xiong, Zhi-Chao; Sun, Tuan-Wei

    2017-03-08

    The templated synthesis of hydroxyapatite (HAP) nanowires@metal-organic framework (MOF) core/shell nanofibers (named HAP@MIL-100(Fe) nanofibers) is demonstrated. The ultralong hydroxyapatite nanowires are adopted as a hard template for the nucleation and growth of MIL-100(Fe) (a typical MOF) through the layer-by-layer method. The Coulombic and chelation interactions between Ca(2+) ions on the surface of the HAP nanowires and the COO(-) organic linkers of MIL-100(Fe) play key roles in the formation process. The as-prepared, water-stable HAP@MIL-100(Fe) nanofibers exhibit peroxidase-like activity toward the oxidation of different peroxidase substrates in the presence of H2 O2 , accompanied by a clear color change of the solution. Furthermore, a flexible, recyclable HAP@MIL-100(Fe) test paper is prepared successfully by using HAP@MIL-100(Fe) nanofibers as building blocks. A simple, low-cost, and sensitive colorimetric method for the detection of H2 O2 and glucose is established based on the as-prepared, flexible, recyclable HAP@MIL-100(Fe) test paper. More importantly, the HAP@MIL-100(Fe) test paper can be recovered easily for reuse by simply dipping in absolute ethanol for just 30 min, thus showing excellent recyclability. With its combination of advantages such as easy transportation, easy storage and use, rapid recyclability, light weight, and high flexibility, this HAP@MIL-100(Fe) test paper is promising for wide applications in various fields.

  4. Towards the establishment of a permanent colony of Drosophila in the International Space Station: hardware tests and adaptation of techniques.

    Science.gov (United States)

    Herranz, R; Husson, D; Pastor, M; Diaz, C; Mateos, J; Villa, A; Medina, F J; Marco, R

    2002-07-01

    Our group has the long-term goal of establishing a permanent colony of Drosophila melanogaster in the International Space Station (ISS) to study its long-term adaptation to this unusual environment. We are currently building an enhanced version of an automatic cultivation unit (ESE1) in which we can grow flies with minimal crew involvement. We are working on a fixation unit as well. We are also adapting current protocols to maintain fixed animals during at least three months, the minimal refurbishment shuttle flight time, with minimal handling and maximal automatization, that can be used for inmuno-cytochemistry, ultrastructure or molecular experiments.

  5. Flexible Sigmoidoscopy

    Science.gov (United States)

    ... Task Force (USPSTF). Most doctors recommend colonoscopy to screen for colon cancer because colonoscopy shows the entire colon and can remove colon polyps. However, preparing for and performing a flexible sigmoidoscopy may take less time and you may ...

  6. Analyzing Virtual Reference Station for GPS surveying: experiments and applications in a test site of the northern Apennine (Italy.

    Directory of Open Access Journals (Sweden)

    G. Casula

    2008-06-01

    Full Text Available The availability of a GPS network of 10-20 km mean size, provides good topographical support for the measurement of ground displacements, even at a local scale such as a landslide. In particular, a series of multitemporal kinematic or rapid-static GPS acquisitions of a landslide allows a good characterization of its displacements if the measurements are referred to a GPS reference network. Nevertheless, a wider network formed by stations located at long distances, for example at several tens of kilometers, characterized by large spacing, can lead to results affected by high noise, degrading the accuracy of final point positions. In order to obtain an adequate GPS reference network, some virtual reference stations (VRSs can be introduced, even if a network refinement based on VRS cannot reach the same accuracy of a real local network. Some experiments, including measurements on a real landslide, have been performed in order to evaluate the performance of this technique. The results point out that the standard deviation of the obtained solutions is about two or three times larger than those which can be reached using a real local network.

  7. International Space Station Sustaining Engineering: A Ground-Based Test Bed for Evaluating Integrated Environmental Control and Life Support System and Internal Thermal Control System Flight Performance

    Science.gov (United States)

    Ray, Charles D.; Perry, Jay L.; Callahan, David M.

    2000-01-01

    As the International Space Station's (ISS) various habitable modules are placed in service on orbit, the need to provide for sustaining engineering becomes increasingly important to ensure the proper function of critical onboard systems. Chief among these are the Environmental Control and Life Support System (ECLSS) and the Internal Thermal Control System (ITCS). Without either, life onboard the ISS would prove difficult or nearly impossible. For this reason, a ground-based ECLSS/ITCS hardware performance simulation capability has been developed at NASA's Marshall Space Flight Center. The ECLSS/ITCS Sustaining Engineering Test Bed will be used to assist the ISS Program in resolving hardware anomalies and performing periodic performance assessments. The ISS flight configuration being simulated by the test bed is described as well as ongoing activities related to its preparation for supporting ISS Mission 5A. Growth options for the test facility are presented whereby the current facility may be upgraded to enhance its capability for supporting future station operation well beyond Mission 5A. Test bed capabilities for demonstrating technology improvements of ECLSS hardware are also described.

  8. Turbine Model Acceptance Test for Jiangbian Hydropower Station%四川九龙河江边水电站水轮机模型验收试验

    Institute of Scientific and Technical Information of China (English)

    方晓红

    2013-01-01

      为检验江边水电站水轮机模型水力设计性能,进行水轮机模型验收试验。模型验收试验项目包括效率试验、空化试验、压力脉动试验、水轮机轴向水推力试验、Winter-Kennedy 指数试验、飞逸转速试验、补气试验等。验收试验结果表明:验收试验的结果与模型初步试验结果一致,满足合同保证值要求。%In order to demonstrate the model turbine hydraulic performance for Jiangbian Hydropower Station, the model acceptance test was carried out. The model turbine acceptance test included efficiency tests, cavitation tests, pressure fluctuation tests, hydraulic axial thrust tests, Winter-Kennedy index tests,runaway tests, air-admission tests and dimensional checks. The test results indicated that the model turbine hydraulic performance could meet guarantee of the contract.

  9. Thin flexible intercalation anodes

    Energy Technology Data Exchange (ETDEWEB)

    Levy, S.C.; Cieslak, W.R.; Klassen, S.E.; Lagasse, R.R.

    1994-10-01

    Poly(acrylonitrile) fibers have been pyrolyzed under various conditions to form flexible carbon yarns capable of intercalating lithium ions. These fibers have also been formed into both woven and non woven cloths. Potentiostatic, potentiodynamic and galvanostatic tests have been conducted with these materials in several electrolytes. In some tests, a potential hold was used after each constant current charge and discharge. These tests have shown some of these flexible materials to reversibly intercalate lithium ions to levels that are suitable for use as a practical battery anode.

  10. Advances in Model-Based Design of Flexible and Prompt Energy Systems -- The CO2 Capture Plant at the Buggenum IGCC Power Station as a Test Case

    NARCIS (Netherlands)

    Trapp, C.

    2014-01-01

    Pre-combustion CO2 capture applied to integrated gasification combined cycle (IGCC) power plants is a promising technical solution to reduce CO2 emissions due to fossil-fuelled electricity generation in order to meet environmental targets in a carbon-constrained future. The pre-combustion capture

  11. Advances in Model-Based Design of Flexible and Prompt Energy Systems -- The CO2 Capture Plant at the Buggenum IGCC Power Station as a Test Case

    NARCIS (Netherlands)

    Trapp, C.

    2014-01-01

    Pre-combustion CO2 capture applied to integrated gasification combined cycle (IGCC) power plants is a promising technical solution to reduce CO2 emissions due to fossil-fuelled electricity generation in order to meet environmental targets in a carbon-constrained future. The pre-combustion capture pr

  12. Testing of a vacuum insulated flexible line with flowing liquid nitrogen during the loss of insulating vacuum

    Energy Technology Data Exchange (ETDEWEB)

    Demko, Jonathan A [ORNL; Duckworth, Robert C [ORNL; Gouge, Michael J [ORNL; Roden, Mark L [ORNL

    2008-01-01

    Long length vacuum insulated lines are used to carry flowing liquid nitrogen in several high temperature superconducting cable projects. An important, but rare, failure scenario is the abrupt or catastrophic loss of the thermal insulating vacuum producing a rapid increase in heat transfer to the liquid nitrogen stream. In this experimental investigation, a vacuum superinsulated 3 inch by 5 inch NPS (88.9 mm by 141.3 mm) flexible cryostat is subjected to an abrupt loss of vacuum in order to measure the thermal response of a flowing liquid nitrogen stream and the temperature response of the cryostat. The measured outlet stream temperature has a slight peak shortly after the loss of vacuum incident and decreases as the cryostat warms up. The heat loads measured before and after the vacuum loss event are reported. Measurements of the temperatures in the multi-layer superinsulation are also discussed.

  13. Nonlinear modeling, strength-based design, and testing of flexible piezoelectric energy harvesters under large dynamic loads for rotorcraft applications

    Science.gov (United States)

    Leadenham, Stephen; Erturk, Alper

    2014-04-01

    There has been growing interest in enabling wireless health and usage monitoring for rotorcraft applications, such as helicopter rotor systems. Large dynamic loads and acceleration fluctuations available in these environments make the implementation of vibration-based piezoelectric energy harvesters a very promising choice. However, such extreme loads transmitted to the harvester can also be detrimental to piezoelectric laminates and overall system reliability. Particularly flexible resonant cantilever configurations tuned to match the dominant excitation frequency can be subject to very large deformations and failure of brittle piezoelectric laminates due to excessive bending stresses at the root of the harvester. Design of resonant piezoelectric energy harvesters for use in these environments require nonlinear electroelastic dynamic modeling and strength-based analysis to maximize the power output while ensuring that the harvester is still functional. This paper presents a mathematical framework to design and analyze the dynamics of nonlinear flexible piezoelectric energy harvesters under large base acceleration levels. A strength-based limit is imposed to design the piezoelectric energy harvester with a proof mass while accounting for material, geometric, and dissipative nonlinearities, with a focus on two demonstrative case studies having the same linear fundamental resonance frequency but different overhang length and proof mass values. Experiments are conducted at different excitation levels for validation of the nonlinear design approach proposed in this work. The case studies in this work reveal that harvesters exhibiting similar behavior and power generation performance at low excitation levels (e.g. less than 0.1g) can have totally different strength-imposed performance limitations under high excitations (e.g. above 1g). Nonlinear modeling and strength-based design is necessary for such excitation levels especially when using resonant cantilevers with no

  14. Next Generation Fast RF Interlock Module and ATCA Adapter for ILC High Availability RF Test Station Demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, R

    2009-10-17

    High availability interlocks and controls are required for the ILC (International Linear Collider) L-Band high power RF stations. A new F3 (Fast Fault Finder) VME module has been developed to process both fast and slow interlocks using FPGA logic to detect the interlock trip excursions. This combination eliminates the need for separate PLC (Programmable Logic Controller) control of slow interlocks. Modules are chained together to accommodate as many inputs as needed. In the next phase of development the F3's will be ported to the new industry standard ATCA (Advanced Telecom Computing Architecture) crate (shelf) via a specially designed VME adapter module with IPMI (Intelligent Platform Management Interface). The goal is to demonstrate auto-failover and hot-swap for future partially redundant systems.

  15. 枕头坝一级水电站水轮机模型验收试验%Acceptance test of turbine model of Zhentouba I Hydropower Station

    Institute of Scientific and Technical Information of China (English)

    柯剑; 李剑君

    2014-01-01

    In order to verify whether the hydraulic performance of turbines of Zhentouba I Hydropower Station meet the contract requirement, the acceptance test of turbine model was carried out on the high pressure hydraulic test stand in a hydraulic labora-tory of Slovenija. The stand and devices of the acceptance test were introduced. The test contents included energy test, cavitation test, pressure fluctuation test, runaway speed test, axial hydraulic thrust test, check of the geometry and size of flow passage components of the turbine model. The results showed that the hydraulic performance of turbines met the requirement of the con-tract.%为了验证枕头坝一级水电站水轮机水力性能是否满足合同要求,在斯诺文尼亚某水力试验室高压水轮机试验台,进行了水轮机模型验收试验。试验主要内容包括能量试验、空化试验、压力脉动试验、飞逸试验、轴向水推力试验、模型水轮机通流部件几何形状及尺寸检查等。试验结果表明,水轮机的水力性能均满足合同要求。

  16. UMTS Network Stations

    Science.gov (United States)

    Hernandez, C.

    2010-09-01

    over the 30 radiometric stations. As a the result, currently it exist a stable, flexible, safe and economic infrastructure of radiometric stations and telecommunications that allows, on the one hand, to have data in real time from all 30 remote weather stations, and on the other hand allows to communicate with them in order to reprogram them and to carry out maintenance works.

  17. Evaluation of the expected moments algorithm and a multiple low-outlier test for flood frequency analysis at streamgaging stations in Arizona

    Science.gov (United States)

    Paretti, Nicholas V.; Kennedy, Jeffrey R.; Cohn, Timothy A.

    2014-01-01

    Flooding is among the costliest natural disasters in terms of loss of life and property in Arizona, which is why the accurate estimation of flood frequency and magnitude is crucial for proper structural design and accurate floodplain mapping. Current guidelines for flood frequency analysis in the United States are described in Bulletin 17B (B17B), yet since B17B’s publication in 1982 (Interagency Advisory Committee on Water Data, 1982), several improvements have been proposed as updates for future guidelines. Two proposed updates are the Expected Moments Algorithm (EMA) to accommodate historical and censored data, and a generalized multiple Grubbs-Beck (MGB) low-outlier test. The current guidelines use a standard Grubbs-Beck (GB) method to identify low outliers, changing the determination of the moment estimators because B17B uses a conditional probability adjustment to handle low outliers while EMA censors the low outliers. B17B and EMA estimates are identical if no historical information or censored or low outliers are present in the peak-flow data. EMA with MGB (EMA-MGB) test was compared to the standard B17B (B17B-GB) method for flood frequency analysis at 328 streamgaging stations in Arizona. The methods were compared using the relative percent difference (RPD) between annual exceedance probabilities (AEPs), goodness-of-fit assessments, random resampling procedures, and Monte Carlo simulations. The AEPs were calculated and compared using both station skew and weighted skew. Streamgaging stations were classified by U.S. Geological Survey (USGS) National Water Information System (NWIS) qualification codes, used to denote historical and censored peak-flow data, to better understand the effect that nonstandard flood information has on the flood frequency analysis for each method. Streamgaging stations were also grouped according to geographic flood regions and analyzed separately to better understand regional differences caused by physiography and climate. The B

  18. The Research of Test Station in Filter Pressure Drop Testing%综合测试台在滤棒吸阻检测中的应用研究

    Institute of Scientific and Technical Information of China (English)

    伊恒伟

    2013-01-01

    In order to find the reason of the deviation between DT and OM-Ⅰ test station in filter pressure drop, we compare the difference of the bias and stability of DT and OM-Ⅰ test station. There is an obvious drift phenomenon in OM-Ⅰ test station. In order to solve that problem, we change the A/D conversion module and modify the formula of the pressure drop. The results showed that: the bias of pressure drop test result can control within 50 Pa by using OM-Ⅰ test station; the frequency of calibration can be extended to once a day. Therefore, the accuracy and stability of the OM-Ⅰ test station is improved after upgrade, the test results are more reliable. And it' s suitable for the pressure drop test in difference environment conditions between the workshop and QC room.%为寻找公司配置的德国Blogwaldt KC公司DT和北京欧美利华公司OM-Ⅰ综合测试台在滤棒吸阻项目检测车间和实验室的检测结果存在偏差的原因,在考察了综合测试台的偏倚和稳定性后,发现OM-Ⅰ综合测试台存在漂移现象明显的问题,并通过更换A/D转换模块、修改吸阻计算公式进行改造.结果显示,OM-Ⅰ综合测试台在改造后可以将车间和实验室的检测结果的偏差控制在50Pa范围内;校准频次可以由每班1次延长至每天1次.因此,改造后的OM-Ⅰ综合测试台检测的准确性和稳定性得到了提升,检测结果更加可靠,适合车间和质检室环境温湿度条件不一致情况下的滤棒吸阻检测.

  19. Genetic associations between daily BW gain and live fleshiness of station-tested young bulls and carcass and meat quality traits of commercial intact males in Piemontese cattle.

    Science.gov (United States)

    Bonfatti, V; Albera, A; Carnier, P

    2013-05-01

    The aim of this study was to investigate genetic relationships between beef traits of station-tested young bulls and carcass and meat quality traits (MQ) of commercial intact males in Piemontese cattle. Phenotypes for daily gain (DG) and live fleshiness traits (width at withers: WW; shoulder muscularity: SM; loin width: LW; loin thickness: LT; thigh muscularity: TM; thigh profile: TP) and thinness of the shin bone (BT) were available for 3,109 and 2,183 performance-tested young bulls, respectively. Carcass daily gain (CDG), carcass conformation (SEUS), pH at 24 h (pH24h) and 8 d after slaughter (pH8d), lightness (L*), redness (a*), yellowness (b*), hue angle (HA), saturation index (SI), drip loss (DL), cooking loss (CL), and shear force (SF) were assessed for 1,208 commercial intact males. (Co) variance components were estimated in a set of twelve 9-traits analyses using REML and linear animal models including all performance-test traits and 1 carcass or MQ trait at a time. Heritabilities ± SE of beef traits ranged from 0.26 ± 0.03 (LW) to 0.47 ± 0.01 (DG), whereas those of carcass traits and MQ from 0.06 ± 0.03 (CL) to 0.63 ± 0.04 (HA). The genetic correlation (rg) between DG and CDG was 0.75 ± 0.10, indicating that DG, as measured at the test station, is a good indicator of the carcass gain achieved by commercial animals under farms conditions. Daily BW gain of station-tested bulls correlated positively with color traits (from 0.11 ± 0.12 to 0.54 ± 0.09), ph8d (rg ± SE = 0.31 ± 0.11), DL (rg ± SE = 0.29 ± 0.17), and CL (rg ± SE = 0.27 ± 0.18). Live fleshiness of station-tested bulls exhibited genetic correlations with MQ of commercial animals that were positive for L* and b* (from 0.13 ± 0.08 to 0.65 ± 0.14) and negative for pH (from -0.27 ± 0.15 to -0.57 ± 0.11), CL (from -0.16 ± 0.23 to -0.43 ± 0.22), and SF (TM: rg ± SE = -0.31 ± 0.15; TP: rg ± SE = -0.41 ± 0.17). The thinness of the shin bone correlated unfavorably with CDG (rg ± SE

  20. Piping Flexibility

    Science.gov (United States)

    1978-01-01

    A NASA computer program aids Hudson Engineering Corporation, Houston, Texas, in the design and construction of huge petrochemical processing plants like the one shown, which is located at Ju'aymah, Saudi Arabia. The pipes handling the flow of chemicals are subject to a variety of stresses, such as weight and variations in pressure and temperature. Hudson Engineering uses a COSMIC piping flexibility analysis computer program to analyze stresses and unsure the necessary strength and flexibility of the pipes. This program helps the company realize substantial savings in reduced engineering time.

  1. Space Station Food System

    Science.gov (United States)

    Thurmond, Beverly A.; Gillan, Douglas J.; Perchonok, Michele G.; Marcus, Beth A.; Bourland, Charles T.

    1986-01-01

    A team of engineers and food scientists from NASA, the aerospace industry, food companies, and academia are defining the Space Station Food System. The team identified the system requirements based on an analysis of past and current space food systems, food systems from isolated environment communities that resemble Space Station, and the projected Space Station parameters. The team is resolving conflicts among requirements through the use of trade-off analyses. The requirements will give rise to a set of specifications which, in turn, will be used to produce concepts. Concept verification will include testing of prototypes, both in 1-g and microgravity. The end-item specification provides an overall guide for assembling a functional food system for Space Station.

  2. LNG接收站工艺管道试压、吹扫%LNG receiving station process piping pressure test and purging

    Institute of Scientific and Technical Information of China (English)

    张华伟; 仇德朋; 鹿晓斌; 曲顺利

    2014-01-01

    LNG receiving station process piping pressure test and purging is the final inspection of construction quality before project put into operation, to ensure that project smoothly has the vital significance. In view of the LNG clean and low temperature properties, pressure test after the pipe cleaner and dry degree is particularly important, the terminal piping pressure test use hydraulic or pneumatic according to the difference of the pressure or medium..This paper introduces the pipeline pressure test, purging process and matters needing attention, to the future of LNG receiving station test, purging process has a certain reference significance.%LNG接收站工艺管道试压、吹扫是工程投运前对施工质量的最终检验,对确保工程顺利投产具有重要的意义。鉴于LNG清洁及低温特性,试压后管道内的清洁度及干燥度显得尤为重要,目前接收站压力试验根据管道压力、介质的不同通常采用水压或气压。本文介绍了LNG工艺管道试压吹扫的方法、流程和注意事项等,对今后的LNG接收站试压、吹扫具有一定的借鉴意义。

  3. Feasibility Test of a Liquid Film Thickness Sensor on a Flexible Printed Circuit Board Using a Three-Electrode Conductance Method.

    Science.gov (United States)

    Lee, Kyu Byung; Kim, Jong Rok; Park, Goon Cherl; Cho, Hyoung Kyu

    2016-12-27

    Liquid film thickness measurements under temperature-varying conditions in a two-phase flow are of great importance to refining our understanding of two-phase flows. In order to overcome the limitations of the conventional electrical means of measuring the thickness of a liquid film, this study proposes a three-electrode conductance method, with the device fabricated on a flexible printed circuit board (FPCB). The three-electrode conductance method offers the advantage of applicability under conditions with varying temperatures in principle, while the FPCB has the advantage of usability on curved surfaces and in relatively high-temperature conditions in comparison with sensors based on a printed circuit board (PCB). Two types of prototype sensors were fabricated on an FPCB and the feasibility of both was confirmed in a calibration test conducted at different temperatures. With the calibrated sensor, liquid film thickness measurements were conducted via a falling liquid film flow experiment, and the working performance was tested.

  4. Flexible and robust methods for rare-variant testing of quantitative traits in trios and nuclear families.

    Science.gov (United States)

    Jiang, Yunxuan; Conneely, Karen N; Epstein, Michael P

    2014-09-01

    Most rare-variant association tests for complex traits are applicable only to population-based or case-control resequencing studies. There are fewer rare-variant association tests for family-based resequencing studies, which is unfortunate because pedigrees possess many attractive characteristics for such analyses. Family-based studies can be more powerful than their population-based counterparts due to increased genetic load and further enable the implementation of rare-variant association tests that, by design, are robust to confounding due to population stratification. With this in mind, we propose a rare-variant association test for quantitative traits in families; this test integrates the QTDT approach of Abecasis et al. [Abecasis et al., ] into the kernel-based SNP association test KMFAM of Schifano et al. [Schifano et al., ]. The resulting within-family test enjoys the many benefits of the kernel framework for rare-variant association testing, including rapid evaluation of P-values and preservation of power when a region harbors rare causal variation that acts in different directions on phenotype. Additionally, by design, this within-family test is robust to confounding due to population stratification. Although within-family association tests are generally less powerful than their counterparts that use all genetic information, we show that we can recover much of this power (although still ensuring robustness to population stratification) using a straightforward screening procedure. Our method accommodates covariates and allows for missing parental genotype data, and we have written software implementing the approach in R for public use.

  5. Flexibility conflict?

    NARCIS (Netherlands)

    Delsen, L.W.M.

    2002-01-01

    The chapter deals with the presupposed conflict of interests between employers and employees resulting from a decoupling of operating hours and working times. It starts from the notion that both long operating hours and flexibility are relative concepts. As there is some discretion, the ultimate

  6. Flexible Consumption

    DEFF Research Database (Denmark)

    Holm Jacobsen, Peter; Pallesen, Trine

    This report presents the first findings from our qualitative study of consumer behaviour vis-à-vis flexible consumption. The main of objective of this report is to present our first round of data from Bornholm, and to assist the design of products/services designed in WP6. In the report, we adopt...

  7. Microbial Challenge Testing of Single Liquid Cathode Feed Water Electrolysis Cells for the International Space Station (ISS) Oxygen Generator Assembly (OGA)

    Science.gov (United States)

    Roy, Robert J.; Wilson, Mark E.; Diderich, Greg S.; Steele, John W.

    2011-01-01

    The International Space Station (ISS) Oxygen Generator Assembly (OGA) operational performance may be adversely impacted by microbiological growth and biofilm formation over the electrolysis cell membranes. Biofilms could hinder the transport of water from the bulk fluid stream to the membranes and increase the cell concentration overpotential resulting in higher cell voltages and a shorter cell life. A microbial challenge test was performed on duplicate single liquid-cathode feed water electrolysis cells to evaluate operational performance with increasing levels of a mixture of five bacteria isolated from ISS and Space Shuttle potable water systems. Baseline performance of the single water electrolysis cells was determined for approximately one month with deionized water. Monthly performance was also determined following each inoculation of the feed tank with 100, 1000, 10,000 and 100,000 cells/ml of the mixed suspension of test bacteria. Water samples from the feed tank and recirculating water loops for each cell were periodically analyzed for enumeration and speciation of bacteria and total organic carbon. While initially a concern, this test program has demonstrated that the performance of the electrolysis cell is not adversely impacted by feed water containing the five species of bacteria tested at a concentration measured as high as 1,000,000 colony forming units (CFU)/ml. This paper presents the methodologies used in the conduct of this test program along with the performance test results at each level of bacteria concentration.

  8. The Cyborg Astrobiologist: Testing a Novelty-Detection Algorithm on Two Mobile Exploration Systems at Rivas Vaciamadrid in Spain and at the Mars Desert Research Station in Utah

    CERN Document Server

    McGuire, P C; Wendt, L; Bonnici, A; Souza-Egipsy, V; Ormo, J; Diaz-Martinez, E; Foing, B H; Bose, R; Walter, S; Oesker, M; Ontrup, J; Haschke, R; Ritter, H

    2009-01-01

    (ABRIDGED)In previous work, two platforms have been developed for testing computer-vision algorithms for robotic planetary exploration (McGuire et al. 2004b,2005; Bartolo et al. 2007). The wearable-computer platform has been tested at geological and astrobiological field sites in Spain (Rivas Vaciamadrid and Riba de Santiuste), and the phone-camera has been tested at a geological field site in Malta. In this work, we (i) apply a Hopfield neural-network algorithm for novelty detection based upon color, (ii) integrate a field-capable digital microscope on the wearable computer platform, (iii) test this novelty detection with the digital microscope at Rivas Vaciamadrid, (iv) develop a Bluetooth communication mode for the phone-camera platform, in order to allow access to a mobile processing computer at the field sites, and (v) test the novelty detection on the Bluetooth-enabled phone-camera connected to a netbook computer at the Mars Desert Research Station in Utah. This systems engineering and field testing hav...

  9. Observation Station

    Science.gov (United States)

    Rutherford, Heather

    2011-01-01

    This article describes how a teacher integrates science observations into the writing center. At the observation station, students explore new items with a science theme and use their notes and questions for class writings every day. Students are exposed to a variety of different topics and motivated to write in different styles all while…

  10. The Tanpopo: An Astrobiology Mission on the International Space Station to Test Panspermia and Quasi-Panspermia Hypotheses

    Science.gov (United States)

    Kobayashi, K.; Fushimi, H.; Hirako, T.; Kawai, J.; Obayashi, Y.; Kaneko, T.; Mita, H.; Yabuta, H.; Imai, E.; Nakagawa, K.; Takahashi, J.; Yokobori, S.; Yoshida, S.; Hasegawa, S.; Hashimoto, H.; Kawai, H.; Marumo, K.; Okudaira, K.; Tabata, M.; Yamashita, M.; Yano, H.; Yamagishi, A.; Tanpopo Wg

    2010-04-01

    The "TANPOPO mission" was proposed, where space dusts are to be captured with aerogel to analyze microorganisms and organics in them. Both pansermia and quasi-panspermia (interplanetary delivery of chemical seeds of life) are tested in the mission.

  11. Control of a flexible rotor active magnetic bearing test rig:a characteristic model based all-coefficient adaptive control approach

    Institute of Scientific and Technical Information of China (English)

    Long DI; Zongli LIN

    2014-01-01

    Active magnetic bearings (AMBs) have found a wide range of applications in high-speed rotating machinery industry. The instability and nonlinearity of AMBs make controller designs difficult, and when AMBs are coupled with a flexible rotor, the resulting complex dynamics make the problems of stabilization and disturbance rejection, which are critical for a stable and smooth operation of the rotor AMB system, even more difficult. Proportional-integral-derivative (PID) control dominates the current AMB applications in the field. Even though PID controllers are easy to implement, there are critical performance limitations associated with them that prevent the more advanced applications of AMBs, which usually require stronger robustness and performance offered by modern control methods such as H-infinity control andμ-synthesis. However, these advanced control designs rely heavily on the relatively accurate plant models and uncertainty characterizations, which are sometimes difficult to obtain. In this paper, we explore and report on the use of the characteristic model based all-coefficient adaptive control method to stabilize a flexible rotor AMB test rig. In spite of the simple structure of such a characteristic model based all-coefficient adaptive controller, both simulation and experimental results show its strong performance.

  12. International challenge to predict the impact of radioxenon releases from medical isotope production on a comprehensive nuclear test ban treaty sampling station

    Energy Technology Data Exchange (ETDEWEB)

    Eslinger, Paul W.; Bowyer, Ted W.; Achim, Pascal; Chai, Tianfeng; Deconninck, Benoit; Freeman, Katie; Generoso, Sylvia; Hayes, Philip; Heidmann, Verena; Hoffman, Ian; Kijima, Yuichi; Krysta, Monika; Malo, Alain; Maurer, Christian; Ngan, Fantine; Robins, Peter; Ross, J. Ole; Saunier, Olivier; Schlosser, Clemens; Schöppner, Michael; Schrom, Brian T.; Seibert, Petra; Stein, Ariel F.; Ungar, Kurt; Yi, Jing

    2016-06-01

    Abstract The International Monitoring System (IMS) is part of the verification regime for the Comprehensive Nuclear-Test-Ban-Treaty Organization (CTBTO). At entry-into-force, half of the 80 radionuclide stations will be able to measure concentrations of several radioactive xenon isotopes produced in nuclear explosions, and then the full network may be populated with xenon monitoring afterward (Bowyer et al., 2013). Fission-based production of 99Mo for medical purposes also releases radioxenon isotopes to the atmosphere (Saey, 2009). One of the ways to mitigate the effect of emissions from medical isotope production is the use of stack monitoring data, if it were available, so that the effect of radioactive xenon emissions could be subtracted from the effect from a presumed nuclear explosion, when detected at an IMS station location. To date, no studies have addressed the impacts the time resolution or data accuracy of stack monitoring data have on predicted concentrations at an IMS station location. Recently, participants from seven nations used atmospheric transport modeling to predict the time-history of 133Xe concentration measurements at an IMS station in Germany using stack monitoring data from a medical isotope production facility in Belgium. Participants received only stack monitoring data and used the atmospheric transport model and meteorological data of their choice. Some of the models predicted the highest measured concentrations quite well (a high composite statistical model comparison rank or a small mean square error with the measured values). The results suggest release data on a 15 min time spacing is best. The model comparison rank and ensemble analysis suggests that combining multiple models may provide more accurate predicted concentrations than any single model. Further research is needed to identify optimal methods for selecting ensemble members and those methods may depend on the specific transport problem. None of the submissions based only

  13. 某地铁车站热烟实验研究%Experimental study on hot smoke test of a subway station

    Institute of Scientific and Technical Information of China (English)

    李乐; 谢元一; 胡忠日

    2011-01-01

    The hot smoke test was carried out in the hall and platform of a subway station to study the smoke flow, and measure the temperature of plume and 2 m high above the ground near the ceiling during the fire, based on which the performance of smoke management system was evaluated. The results showed that the smoke management system in this station can reach the target of smoke venting; taking the evacuation gateway as natural secondary air opening can prevent the invading of the smoke; using fire and smoke source under control to carry out hot smoke test can simulate the true fire scene and test the smoke evacuation system, and it can help with the evaluation of smoke design in big and complex buildings.%在某地铁车站站厅和站台开展热烟实验,研究烟气流动情况,测量火灾时羽流及距离地面2 m高度处顶棚温度变化情况,在此基础上评价其排烟系统性能.结果表明,该车站内烟控系统能达到排烟目标;采用人员疏散出入口作为自然补风口,可避免烟气对疏散出入口的侵袭;在已建成建筑内采用受控的火源和烟源,用热烟实验方法可模拟真实火灾场景并测试排烟系统性能,也可以作为验证和评估大型复杂建筑内防排烟设计的手段.

  14. Flexible isotopy classification of flexible links

    OpenAIRE

    Björklund, Johan

    2012-01-01

    In this paper we define and study flexible links and flexible isotopy in projective space. Flexible links are meant to capture the topological properties of real algebraic links. We classify all flexible links up to flexible isotopy using Ekholms interpretation of Viros encomplexed writhe.

  15. Flexible metal bellows

    CERN Multimedia

    1975-01-01

    A set of flexible metal bellows being fatigue-tested by repeated offset motion. Such bellows assemblies were used in the SPS vacuum system at places where , for instance, beam stoppers and collimators had to be moved frequently in and out of the beam path.

  16. Flexible Capitalism

    DEFF Research Database (Denmark)

    Approaching “work” as at heart a practice of exchange, this volume explores sociality in work environments marked by the kind of structural changes that have come to define contemporary “flexible” capitalism. It introduces anthropological exchange theory to a wider readership, and shows how...... the perspective offers new ways to enquire about the flexible capitalism’s social dimensions. The essays contribute to a trans-disciplinary scholarship on contemporary economic practice and change by documenting how, across diverse settings, “gift-like” socialities proliferate, and even sustain the intensified...... flexible commoditization that more commonly is touted as tearing social relations apart. By interrogating a keenly debated contemporary work regime through an approach to sociality rooted in a rich and distinct anthropological legacy, the volume also makes a novel contribution to the anthropological...

  17. Método integral configurable y flexible de ensayo de materiales consumibles de soldadura por arco eléctrico. // Integral, flexible and shaped method for electric arc welding consumable materials test.

    Directory of Open Access Journals (Sweden)

    A. García Rodríguez

    2005-05-01

    Full Text Available La presente publicación propone un método integral configurable y flexible para facilitar el ensayo de materialesconsumibles de soldadura por arco eléctrico en las condiciones tecnológicas para las que han sido diseñados estosmateriales, en relación a la calidad de la unión soldada. Se puede llegar a conclusiones definitivas sobre la calidad de lasoldadura usando un determinado material consumible mediante: la relación operacional de técnicas de inteligencia naturaly/o artificial, el uso de sistemas expertos, el trabajo con bases de datos, la simulación y la realización práctica del procesomientras se registran ciertos parámetros del arco eléctrico, digitalmente procesados estadísticamente y relacionados a losresultados de la caracterización de la unión soldada. El método permite registrar adecuadamente la información referente acada aspecto del proceso exigida en los procesos de certificación de la calidad de los consumibles, así como en lainvestigación dirigida a optimizar la composición química y las propiedades físicas de un material, para obtener calidadesóptimas en un determinado proceso; además es posible obtener las bases de datos de parámetros del arco eléctrico útilespara investigar, desarrollar y valorar métodos y algoritmos para el monitoreo en tiempo real de la calidad de la soldaduradurante un determinado proceso tecnológico de soldadura con arco eléctrico.Palabras Clave: Ensayo, materiales, soldadura, arco eléctrico, estabilidad, calidad, simulación, optimización,unión soldada.___________________________________________________________________________Abstract.This paper presenst an integral, flexible and shaped method that make easy the electric arc welding consumable materials test at thedesigned technological conditions, related to the quality of the welding joint. It is possible to arrive to definitive conclusions about thewelding quality using a fixed material through: operational

  18. The Cyborg Astrobiologist: testing a novelty detection algorithm on two mobile exploration systems at Rivas Vaciamadrid in Spain and at the Mars Desert Research Station in Utah

    Science.gov (United States)

    McGuire, P. C.; Gross, C.; Wendt, L.; Bonnici, A.; Souza-Egipsy, V.; Ormö, J.; Díaz-Martínez, E.; Foing, B. H.; Bose, R.; Walter, S.; Oesker, M.; Ontrup, J.; Haschke, R.; Ritter, H.

    2010-01-01

    In previous work, a platform was developed for testing computer-vision algorithms for robotic planetary exploration. This platform consisted of a digital video camera connected to a wearable computer for real-time processing of images at geological and astrobiological field sites. The real-time processing included image segmentation and the generation of interest points based upon uncommonness in the segmentation maps. Also in previous work, this platform for testing computer-vision algorithms has been ported to a more ergonomic alternative platform, consisting of a phone camera connected via the Global System for Mobile Communications (GSM) network to a remote-server computer. The wearable-computer platform has been tested at geological and astrobiological field sites in Spain (Rivas Vaciamadrid and Riba de Santiuste), and the phone camera has been tested at a geological field site in Malta. In this work, we (i) apply a Hopfield neural-network algorithm for novelty detection based upon colour, (ii) integrate a field-capable digital microscope on the wearable computer platform, (iii) test this novelty detection with the digital microscope at Rivas Vaciamadrid, (iv) develop a Bluetooth communication mode for the phone-camera platform, in order to allow access to a mobile processing computer at the field sites, and (v) test the novelty detection on the Bluetooth-enabled phone camera connected to a netbook computer at the Mars Desert Research Station in Utah. This systems engineering and field testing have together allowed us to develop a real-time computer-vision system that is capable, for example, of identifying lichens as novel within a series of images acquired in semi-arid desert environments. We acquired sequences of images of geologic outcrops in Utah and Spain consisting of various rock types and colours to test this algorithm. The algorithm robustly recognized previously observed units by their colour, while requiring only a single image or a few images to

  19. Comparação entre dois testes clínicos para avaliar a flexibilidade dos músculos posteriores da coxa Comparison between two clinical tests for evaluating the flexibility of the posterior muscles of the thigh

    Directory of Open Access Journals (Sweden)

    RL Carregaro

    2007-04-01

    -examiner reliability of the photogrammetric analysis procedure. METHOD: The tests were applied to 35 healthy male subjects (mean age 23 ± 3.4 years, height 170 ± 4 cm and weight 68 ± 11 kg. The subjects were divided into two groups on the basis of the test classifications. Surface markers were placed on bone references in order to calculate the hip, thoracolumbar, leg, knee and tibiotarsal angles. The reliability of the photogrammetric analysis procedure on the angles measured by two examiners was tested. RESULTS: For the hip angle, there were significant differences between the flexibility groups in both tests, and subjects with reduced flexibility had lower angles. There was a significant difference (22.8% between the classifications designated by the two tests. However, the hip angle showed high levels of concordance between the tests (ICC: 0.89 and mean difference of -0.85º. The photogrammetric procedures presented high reliability rates, both for intra and inter-examiner (ICC ranging from 0.94 to 0.99. CONCLUSION: The tests presented differences in the classification of the subjects' flexibility. However, considering the hip angle, there was high concordance between the test results. The photogrammetric analysis procedures were reproducible, both for intra and for inter-examiner measurements, thus making this a useful analysis tool for the tests in question.

  20. Function Machines & Flexible Algebraic Thought.

    Science.gov (United States)

    Davis, Gary E.; McGowen, Mercedes A.

    This paper explores how college students understand ideas of functions, and which representations are productive for them in promoting their ability to work flexibly across representations. The study used pre- and post-test scores, and triangulations via student self evaluations, to generate a hypothesis related to flexible thinking and success in…

  1. Case Study of Risk Mitigation Based on Hardware/Software Integration (HSI) Testing for the International Space Station (ISS) Node 2 Module

    Science.gov (United States)

    Holt, James Mike; Clanton, Stephen Edward

    2004-01-01

    Within the pressurized elements of the International Space Station (ISS), requirements exist to ensure a safe, habitable environment for the crew. In order to provide this environment, thermal control components work in conjunction with software controls to provide heat rejection for subsystem avionics equipment, for the environmental control system and for experiment payloads. It is essential to ISS operations, mission success and crew safety that necessary testing incorporates the extreme conditions to ensure proper performance. This paper provides a general description and methodology applied to thermal related Hardware/Software Integration (HSI) tests for the ISS Node 2 module. A detailed test plan was developed and implemented with two objectives: the first was for risk mitigation of the thermal control algorithms and software qualification, and the second was for data collection which will substantiate thermalhydraulic models of the Internal Active Thermal Control System (IATCS). Analytical models are utilized to determine on-orbit performance for conditions and scenarios where the simulation of actual on-orbit system performance is limited by test configuration constraints. Node 2 IATCS HSI activities were performed at the Alenia Spazio facility in Torino, Italy with participation from the National Aeronautics and Space Administration (NASA), Alenia Spazio, Jacobs Engineering Sverdrup (JE Sverdrup) and Boeing.

  2. 引水式水电站压力前池的控制与检测%Control and Test of Pressure Forebay in Water Diversion Type Hydropower Station

    Institute of Scientific and Technical Information of China (English)

    张豹平

    2014-01-01

    Control and testing of forebay in water diversion type hydropower station as well as measures to improve economic benefits of water diversion type hydropower station are introduced in the paper in details.%本文对引水式水电站压力前池的控制、检测,以及提高引水式水电站经济效益的措施,作了详细介绍。

  3. ULTRA BARRIER TOPSHEET (UBT) FOR FLEXIBLE PHOTOVOLTAICS

    Energy Technology Data Exchange (ETDEWEB)

    DeScioli, Derek

    2013-06-01

    This slide-show presents 3M photovoltaic-related products, particularly flexible components. Emphasis is on the 3M Ultra Barrier Solar Films. Topics covered include reliability and qualification testing and flexible photovoltaic encapsulation costs.

  4. Development of Flow Boiling and Condensation Experiment on the International Space Station- Normal and Low Gravity Flow Boiling Experiment Development and Test Results

    Science.gov (United States)

    Nahra, Henry K.; Hall, Nancy R.; Hasan, Mohammad M.; Wagner, James D.; May, Rochelle L.; Mackey, Jeffrey R.; Kolacz, John S.; Butcher, Robert L.; Frankenfield, Bruce J.; Mudawar, Issam; hide

    2013-01-01

    Flow boiling and condensation have been identified as two key mechanisms for heat transport that are vital for achieving weight and volume reduction as well as performance enhancement in future space systems. Since inertia driven flows are demanding on power usage, lower flows are desirable. However, in microgravity, lower flows are dominated by forces other than inertia (like the capillary force). It is of paramount interest to investigate limits of low flows beyond which the flow is inertial enough to be gravity independent. One of the objectives of the Flow Boiling and Condensation Flight Experiment sets to investigate these limits for flow boiling and condensation. A two-phase flow loop consisting of a Flow Boiling Module and two Condensation Modules has been developed to experimentally study flow boiling condensation heat transfer in the reduced gravity environment provided by the reduced gravity platform. This effort supports the development of a flow boiling and condensation facility for the International Space Station (ISS). The closed loop test facility is designed to deliver the test fluid, FC-72 to the inlet of any one of the test modules at specified thermodynamic and flow conditions. The zero-g-aircraft tests will provide subcooled and saturated flow boiling critical heat flux and flow condensation heat transfer data over wide range of flow velocities. Additionally, these tests will verify the performance of all gravity sensitive components, such as evaporator, condenser and accumulator associated with the two-phase flow loop. We will present in this paper the breadboard development and testing results which consist of detailed performance evaluation of the heater and condenser combination in reduced and normal gravity. We will also present the design of the reduced gravity aircraft rack and the results of the ground flow boiling heat transfer testing performed with the Flow Boiling Module that is designed to investigate flow boiling heat transfer and

  5. Corrective Action Decision Document for Corrective Action Unit 490: Station 44 Burn Area, Tonopah Test Range, Nevada (Rev. No.: 0, February 2001)

    Energy Technology Data Exchange (ETDEWEB)

    DOE/NV

    2001-02-23

    This Corrective Action Decision Document identifies and rationalizes the U.S. Department of Energy, Nevada Operations Office's selection of a recommended Corrective Action Alternative (CAA) appropriate to facilitate the closure of Corrective Action Unit (CAU) 490, Station 44 Burn Area, Tonopah Test Range (TTR), Nevada, under the Federal Facility Agreement and Consent Order. Corrective Action Unit 490 is located on the Nellis Air Force Range and the Tonopah Test Range and is approximately 140 miles northwest of Las Vegas, Nevada. This CAU is comprised of four Corrective Action Sites (CASs): 03-56-001-03BA, Fire Training Area (located southwest of Area 3); RG-56-001-RGBA, Station 44 Burn Area (located west of Main Lake); 03-58-001-03FN, Sandia Service Yard (located north of the northwest corner of Area 3); and 09-54-001-09L2, Gun Propellant Burn Area (located south of the Area 9 Compound on the TTR). A Corrective Action Investigation was performed in July and August 2000, and analytes detected during the corrective action investigation were evaluated against preliminary action levels to determine contaminants of concern (COCs). There were no COCs identified in soil at the Gun Propellant Burn Area or the Station 44 Burn Area; therefore, there is no need for corrective actions at these two sites. Five soil samples at the Fire Training Area and seven at the Sandia Service Yard exceeded PALs for total petroleum hydrocarbons-diesel. Upon the identification of COCs specific to CAU 490, Corrective Action Objectives were developed based on a review of existing data, future use, and current operations at the TTR, with the following three CAAs under consideration: Alternative 1 - No Further Action, Alternative 2 - Closure In Place - No Further Action With Administrative Controls, and Alternative 3 - Clean Closure by Excavation and Disposal. These alternatives were evaluated based on four general corrective action standards and five remedy selection decision factors. Based

  6. Uranium from Seawater Marine Testing Program at the University of Miami’s Broad Key Island Research Station

    Energy Technology Data Exchange (ETDEWEB)

    Gill, Gary A. [Pacific Northwest National Lab. (PNNL), Sequim, WA (United States). Marine Sciences Lab.; Kuo, Li-Jung [Pacific Northwest National Lab. (PNNL), Sequim, WA (United States). Marine Sciences Lab.; Strivens, Jonathan E. [Pacific Northwest National Lab. (PNNL), Sequim, WA (United States). Marine Sciences Lab.; Wood, Jordana R. [Pacific Northwest National Lab. (PNNL), Sequim, WA (United States). Marine Sciences Lab.; Schlafer, Nicholas J. [Pacific Northwest National Lab. (PNNL), Sequim, WA (United States). Marine Sciences Lab.; D' Alessandro, Evan [Univ. of Miami, FL (United States). Rosensteil School of Marine and Atmospheric Sciences

    2016-09-30

    Marine testing at Broad Key Island (BKI), Florida was conducted to validate adsorption capacity and adsorption kinetics results obtained for several formulations of the ORNL amidoxime-based polymeric adsorbents in Sequim Bay, Washington in another location with different oceanographic and water quality conditions (e.g. temperature, dissolved organic carbon, salinity and trace element content). Broad Key is a small island off the southeast coast of Florida at the southern end of Biscayne Bay. Flow-through column and recirculating flume experiments were conducted at BKI using ambient filtered seawater and identical exposure systems as were used at the Pacific Northwest National Laboratory’s (PNNL) Marine Sciences laboratory (MSL). Testing was conducted in two periods in FY 2015 and FY 2016 with five different amidoxime-based adsorbent materials, four produced by ORNL (AF1, AI8, AF8, and AF1-DMSO) and one by LCW technologies (LCW-10). All exposures were conducted at ambient seawater temperatures, with moderate temperature control on the ambient seawater to mitigate large daily swings in the seawater temperature. The ORNL adsorbents AF1, AI8 and AF1-AO-DMSO all had fairly similar adsorption capacities (6.0 to 6.6 g U/ kg adsorbent) after 56 days of exposure at ambient temperature (26 to 31 °C) and salinity (35.7 to 37.4), but the AF8 adsorbent was considerably lower at 4.4 g U/kg adsorbent. All the adsorbents tested at BKI had higher capacities than was observed at PNNL, with the higher temperatures likely a major factor contributing to this difference. In general, the elemental distribution (expressed as a relative percentage) on all the adsorbents agreed well, including good agreement with the elemental distribution pattern for AF1 adsorbent exposed at PNNL. The most notable exception to a uniform elemental distributional pattern across the various adsorbents occurs with vanadium. The relative mass percentage for vanadium retained by the adsorbents ranged from a

  7. Cryogenic design and test results of 30-m flexible hybrid energy transfer line with liquid hydrogen and superconducting MgB2 cable

    Science.gov (United States)

    Kostyuk, V. V.; Blagov, E. V.; Antyukhov, I. V.; Firsov, V. P.; Vysotsky, V. S.; Nosov, A. A.; Fetisov, S. S.; Zanegin, S. Yu.; Svalov, G. G.; Rachuk, V. S.; Katorgin, B. I.

    2015-03-01

    In this paper we present the development of a new hybrid energy transfer line with 30 m length. The line is essentially a flexible 30 m hydrogen cryostat that has three sections with different types of thermal insulation in each section: simple vacuum superinsulation, vacuum superinsulation with liquid nitrogen precooling and active evaporating cryostatting (AEC) system. We performed thermo-hydraulic tests of the cryostat to compare three thermo-insulating methods. The tests were made at temperatures from 20 to 26 K, hydrogen flow from 70 to 450 g/s and pressure from 0.25 to 0.5 MPa. It was found that AEC thermal insulation was the most effective in reducing heat transfer from room temperature to liquid hydrogen in ∼10 m section of the cryostat, indicating that it can be used for long superconducting power cables. High voltage current leads were developed as well. The current leads and superconducting MgB2 cable passed high voltage DC test up to 50 kV DC. Critical current of the cable at ∼21 K was 3500 A. It means that the 30 m hybrid energy system developed is able to deliver ∼50-60 MW of chemical power and ∼50-75 MW of electrical power, i.e. up to ∼135 MW in total.

  8. Flexible Capitalism

    DEFF Research Database (Denmark)

    Approaching “work” as at heart a practice of exchange, this volume explores sociality in work environments marked by the kind of structural changes that have come to define contemporary “flexible” capitalism. It introduces anthropological exchange theory to a wider readership, and shows how...... the perspective offers new ways to enquire about the flexible capitalism’s social dimensions. The essays contribute to a trans-disciplinary scholarship on contemporary economic practice and change by documenting how, across diverse settings, “gift-like” socialities proliferate, and even sustain the intensified...

  9. The Space Station

    Science.gov (United States)

    Sharples, R.; Hieatt, J.

    1984-11-01

    The configuration of the Space Station under design studies by NASA is limited only by the capabilities of the Shuttle and the purposes to which it is applied. Once the standard interlocks, launch vibration modes, and pallet designs are fixed, all other assembly of modular components, testing, and trim will be performed in space. The Station will serve for long-term experiments, as a base for planetary missions asembly, launch, and retrieval, and for loading and launching multiple satellites on an orbital transfer vehicle. Materials processing research will be carried out in the Station, as will various scientific and commercial remote sensing activities. The first operational version (1990) will require four Shuttle launches to reach an assembled mass of 70,000 kg drawing 30 kWe from solar panels and housing a crew of five. By the year 2000 the station will support 10-12 crew members in five habitat modules, will be 31 m long, will have cost $18-20 billion, and will be returning $2 billion per year. The station will be periodically reboosted to higher orbits that decay suficiently for orbiter rendezvous for supplies and assignments.

  10. [Tests on the bactericidal effectiveness of iodophor A in the halls of a pig-fattening station].

    Science.gov (United States)

    Kubícek, K

    1975-04-01

    In the halls of the pig fattening house the bactericidal effectiveness of cold water solutions of Czechoslovakia-made Jodofor A and the product of the Ciba-Geigy company Iosan was tested and compared with the effectiveness of Chloramin B used in a water solution at the temperature of 50 to 60 degrees C. The solutions were applied by fine spraying at the rate of 0.5 lt. per 1 m2 of area. After one hour the spray was applied again at the same rate. One hour after the last Jodofor spray and two hours after the last Chloramin B spray, smears were collected from the disinfected surfaces. The examination included the detection of coliform germs, germs of the Micrococcaceae family, and the determination of the total number of germs. On the whole, 384 smears were examined in four separate trials. The application of Jodofor A in 2% concentrations, after mechanical average-quality purification, did not give acceptable results, in comparison with the solution of Cloramin B. Only when solutions of Jodofor A and Iosan were used in 3% concentration after perfect mechanical purification, satisfactory results were obtained (with the exception of plaster and painted wood), in comparison with the Chloramin B solution. Better disinfectibility was found in aluminium sheet, terracotta, concrete, and metal, as distinct from plaster and painted wood. The comparison of Jodofor A with abroad-male Iosan indicates that Jodofor has the same or a better bactericidal effect than Iosan in all indices. Due to its bactericidal effect, Jodofor A is a suitable disinfectant for preventive disinfection of farm animal houses. In order to achieve results corresponding to those provided by 2% solutions of Chloramin B it is necessary to use at least 3% concentration of Jodofor A. Good mechanical purification is a basic prerequisite for its effectiveness.

  11. Examination of Communication Delays on Team Performance: Utilizing the International Space Station (ISS) as a Test Bed for Analog Research

    Science.gov (United States)

    Keeton, K. E.; Slack, K, J.; Schmidt, L. L.; Ploutz-Snyder, R.; Baskin, P.; Leveton, L. B.

    2011-01-01

    Operational conjectures about space exploration missions of the future indicate that space crews will need to be more autonomous from mission control and operate independently. This is in part due to the expectation that communication quality between the ground and exploration crews will be more limited and delayed. Because of potential adverse effects on communication quality, both researchers and operational training and engineering experts have suggested that communication delays and the impact these delays have on the quality of communications to the crew will create performance decrements if crews are not given adequate training and tools to support more autonomous operations. This presentation will provide an overview of a research study led by the Behavioral Health and Performance Element (BHP) of the NASA Human Research Program that examines the impact of implementing a communication delay on ISS on individual and team factors and outcomes, including performance and related perceptions of autonomy. The methodological design, data collection efforts, and initial results of this study to date will be discussed . The results will focus on completed missions, DRATS and NEEMO15. Lessons learned from implementing this study within analog environments will also be discussed. One lesson learned is that the complexities of garnishing a successful data collection campaign from these high fidelity analogs requires perseverance and a strong relationship with operational experts. Results of this study will provide a preliminary understanding of the impact of communication delays on individual and team performance as well as an insight into how teams perform and interact in a space-like environment . This will help prepare for implementation of communication delay tests on the ISS, targeted for Increment 35/36.

  12. Component Testing for Modular Pier Replacement at McMurdo Station, Antarctica: Inflatable Pontoons, Gelbo Flex and Full-Scale Cold Storage/Fold Tests

    Science.gov (United States)

    2014-08-01

    40 4 0 10,000 No leaks Welded -4 Vulcanized −40 4 0 10,000 No leaks ERDC/CRREL TR-14-14 8 The LMCS pontoon fabric (samples Pontoon-1 to 3...cracking or leaks in the fabric or fabric joint welds . Upon receiving the pontoon, we inflated it and determined that there were 5 leaks caused from prior...durability and strength of the pontoon fabric when tested at Antarctic temperatures by using a cold-modified Gelbo flex (ASTM F392) test. The

  13. International challenge to predict the impact of radioxenon releases from medical isotope production on a comprehensive nuclear test ban treaty sampling station.

    Science.gov (United States)

    Eslinger, Paul W; Bowyer, Ted W; Achim, Pascal; Chai, Tianfeng; Deconninck, Benoit; Freeman, Katie; Generoso, Sylvia; Hayes, Philip; Heidmann, Verena; Hoffman, Ian; Kijima, Yuichi; Krysta, Monika; Malo, Alain; Maurer, Christian; Ngan, Fantine; Robins, Peter; Ross, J Ole; Saunier, Olivier; Schlosser, Clemens; Schöppner, Michael; Schrom, Brian T; Seibert, Petra; Stein, Ariel F; Ungar, Kurt; Yi, Jing

    2016-06-01

    The International Monitoring System (IMS) is part of the verification regime for the Comprehensive Nuclear-Test-Ban-Treaty Organization (CTBTO). At entry-into-force, half of the 80 radionuclide stations will be able to measure concentrations of several radioactive xenon isotopes produced in nuclear explosions, and then the full network may be populated with xenon monitoring afterward. An understanding of natural and man-made radionuclide backgrounds can be used in accordance with the provisions of the treaty (such as event screening criteria in Annex 2 to the Protocol of the Treaty) for the effective implementation of the verification regime. Fission-based production of (99)Mo for medical purposes also generates nuisance radioxenon isotopes that are usually vented to the atmosphere. One of the ways to account for the effect emissions from medical isotope production has on radionuclide samples from the IMS is to use stack monitoring data, if they are available, and atmospheric transport modeling. Recently, individuals from seven nations participated in a challenge exercise that used atmospheric transport modeling to predict the time-history of (133)Xe concentration measurements at the IMS radionuclide station in Germany using stack monitoring data from a medical isotope production facility in Belgium. Participants received only stack monitoring data and used the atmospheric transport model and meteorological data of their choice. Some of the models predicted the highest measured concentrations quite well. A model comparison rank and ensemble analysis suggests that combining multiple models may provide more accurate predicted concentrations than any single model. None of the submissions based only on the stack monitoring data predicted the small measured concentrations very well. Modeling of sources by other nuclear facilities with smaller releases than medical isotope production facilities may be important in understanding how to discriminate those releases from

  14. Experimental Testing of Nonredundant Near-Field to Far-Field Transformations with Spherical Scanning Using Flexible Modellings for Nonvolumetric Antennas

    Directory of Open Access Journals (Sweden)

    Francesco D'Agostino

    2013-01-01

    Full Text Available This paper deals with the experimental testing of effective probe compensated near-field-far-field (NF-FF transformations with spherical scanning requiring a minimum number of NF data. They rely on nonredundant sampling representations of the voltage measured by the probe, based on very flexible source modellings suitable for nonvolumetric antennas characterized by two dimensions very different from the other one. In particular, a cylinder ended in two half-spheres is adopted for modelling long antennas, whereas the quasi-planar ones are considered as enclosed in a rotational surface formed by two circular “bowls” having the same aperture diameter, but eventually different bending radii. The NF data needed to perform the classical spherical NF-FF transformation are then accurately and efficiently retrieved from the acquired nonredundant ones via optimal sampling interpolation formulas. A remarkable reduction of the number of the required NF data and, as a consequence, a significant measurement time saving can be so obtained. The experimental tests have been carried out at Antenna Characterization Lab of the University of Salerno and both the NF and FF reconstructions are resulted to be very good, thus confirming the accuracy and reliability of these NF-FF transformations from the experimental viewpoint too.

  15. Flexible protection for metal bellows

    Science.gov (United States)

    Kimble, K. G.

    1970-01-01

    RTV silicone is used with a braided wire sheath surrounding the metal bellows in fluid transfer systems. It demonstrated best overall performance in flexibility and shock absorbing tests, high temperature, low temperature, and salt spray.

  16. Flexible Blades for Wind Turbines

    Science.gov (United States)

    Collins, Madeline Carlisle; Macphee, David; Harris, Caleb

    2016-11-01

    Previous research has shown that windmills with flexible blades are more efficient than those with rigid blades. Flexibility offers passive pitch control, preferable to active pitch control which is costly and requires maintenance. Flexible blades morph such that the blade more closely resembles its design point at part load and over load. The lift-to-drag ratios on individual blades was investigated. A mold was designed and machined from an acrylic slab for the casting of blades with a NACA 0012 cross section. A flexible blade was cast from silicone and a rigid blade was cast from polyurethane. Each of these blades was tested in a wind tunnel, cantilever mounted, spanning the whole test section. The angle of attack was varied by rotating the mount. All tests were performed at the same wind speed. A load cell within the mount measured forces on the blade, from which the lift and drag forces were calculated. The stall point for the flexible blade occurred later than for the rigid blade, which agrees with previous research. Lift-to-drag ratios were larger for the flexible blade at all angles of attack tested. Flexible blades seem to be a viable option for passive pitch control. Future research will include different airfoil cross sections, wind speeds, and blade materials. Funding from NSF REU site Grant EEC 1358991 is greatly appreciated.

  17. 跨铁路站场斜拉桥荷载试验分析%Analysis on Loading Test of Cable-stayed Bridge Spanning Railway Station

    Institute of Scientific and Technical Information of China (English)

    刘邵平

    2011-01-01

    和平大桥位于城市主干道上,跨越徐州铁路站场,铁路交通量极大。为了检验成桥后该桥梁承载能力是否满足正常使用状况的要求以及评估实际结构的动力性能,对全桥展开荷载试验分析。研究结果表明,和平大桥的受力性能和正常使用状态极限承载力满足设计荷载等级城-A级要求,结构工作状况良好。%Heping bridge with heavy-volume traffic is located at urban arterial road and spans a railway station.To test wheather the bearing capacity under normal service loading could meet criterion or not and evaluate the dynamic characteristics of the bridge,loading test analysis is proposed in this paper.The results show that the mechanical behavior and the ultimate bearing capacity under normal service loading of Heping bridge meet the design load grade-A standard and Heping bridge is in good working condition.

  18. Flexible solar-array mechanism

    Science.gov (United States)

    Olson, M. C.

    1972-01-01

    One of the key elements of the flexible rolled-up solar array system is a mechanism to deploy, retract, and store the flexible solar-cell arrays. The selection of components, the design of the mechanism assembly, and the tests that were performed are discussed. During 6 months in orbit, all mission objectives were satisfied, and inflight performance has shown good correlation with preflight analyses and tests.

  19. Remote manual operator for space station intermodule ventilation valve

    Science.gov (United States)

    Guyaux, James R.

    1996-01-01

    The Remote Manual Operator (RMO) is a mechanism used for manual operation of the Space Station Intermodule Ventilation (IMV) valve and for visual indication of valve position. The IMV is a butterfly-type valve, located in the ventilation or air circulation ducts of the Space Station, and is used to interconnect or isolate the various compartments. The IMV valve is normally operated by an electric motor-driven actuator under computer or astronaut control, but it can also be operated manually with the RMO. The IMV valve RMO consists of a handle with a deployment linkage, a gear-driven flexible shaft, and a linkage to disengage the electric motor actuator during manual operation. It also provides visual indication of valve position. The IMV valve RMO is currently being prepared for qualification testing.

  20. Compressor station layout considerations

    Energy Technology Data Exchange (ETDEWEB)

    Kurz, Rainer; Ohanian, Sebouh; Lubomirsky, Matt [Solar Turbines Incorporated, San Diego, CA (United States)

    2003-07-01

    This paper discusses issues that influence the decision on the arrangement of compressors and the type of equipment in gas pipeline compressor stations. Different concepts such as multiple small units versus single large units are considered, both regarding their impact on the individual station and the overall pipeline. The necessity of standby units is discussed. Various concepts for drivers (gas turbine, gas motor and electric motor) and compressors (centrifugal and reciprocating) are analyzed. The importance of considering all possible operating conditions is stressed. With the wide range of possible operating conditions for the pipeline in mind, the discussion is brought into the general context of operational flexibility, availability, reliability, installation issues, remote control, and operability of gas turbine driven centrifugal compressors compared to other solutions such as electric motor driven compressors or gas engine driven reciprocating compressors. The impact of different concepts on emissions and fuel cost is discussed. Among the assumptions in this paper are the performance characteristics of the compressor. This paper outlines how these performance characteristics influence the conclusions. (author)

  1. Geologic and hydrologic records of observation wells, test holes, test wells, supply wells, springs, and surface water stations in the Los Alamos area

    Energy Technology Data Exchange (ETDEWEB)

    Purtymun, W.D.

    1995-01-01

    Hundreds of holes have been drilled into the Pajarito Plateau and surrounding test areas of the Los Alamos National Laboratory since the end of World War II. They range in depth from a few feet to more than 14,000 ft. The holes were drilled to provide geologic, hydrologic, and engineering information related to development of a water supply, to provide data on the likelihood or presence of subsurface contamination from hazardous and nuclear materials, and for engineering design for construction. The data contained in this report provide a basis for further investigations into the consequences of our past, present, and future interactions with the environment.

  2. Strain Monitoring of Flexible Structures

    Science.gov (United States)

    Litteken, Douglas A.

    2017-01-01

    One of the biggest challenges facing NASA's deep space exploration goals is structural mass. A long duration transit vehicle on a journey to Mars, for example, requires a large internal volume for cargo, supplies and crew support. As with all space structures, a large pressure vessel is not enough. The vehicle also requires thermal, micro-meteoroid, and radiation protection, a navigation and control system, a propulsion system, and a power system, etc. As vehicles get larger, their associated systems also get larger and more complex. These vehicles require larger lift capacities and force the mission to become extremely costly. In order to build large volume habitable vehicles, with only minimal increases in launch volume and mass, NASA is developing lightweight structures. Lightweight structures are made from non-metallic materials including graphite composites and high strength fabrics and could provide similar or better structural capability than metals, but with significant launch volume and mass savings. Fabric structures specifically, have been worked by NASA off and on since its inception, but most notably in the 1990's with the TransHAB program. These TransHAB developed structures use a layered material approach to form a pressure vessel with integrated thermal and micro-meteoroid and orbital debris (MMOD) protection. The flexible fabrics allow the vessel to be packed in a small volume during launch and expand into a much larger volume once in orbit. NASA and Bigelow Aerospace recently installed the first human-rated inflatable module on the International Space Station (ISS), known as the Bigelow Expandable Activity Module (BEAM) in May of 2016. The module provides a similar internal volume to that of an Orbital ATK Cygnus cargo vehicle, but with a 77% launch volume savings. As lightweight structures are developed, testing methods are vital to understanding their behavior and validating analytical models. Common techniques can be applied to fabric materials

  3. Modernized build and test infrastructure for control software at ESO: highly flexible building, testing, and automatic quality practices for telescope control software

    Science.gov (United States)

    Pellegrin, F.; Jeram, B.; Haucke, J.; Feyrin, S.

    2016-07-01

    The paper describes the introduction of a new automatized build and test infrastructure, based on the open-source software Jenkins1, into the ESO Very Large Telescope control software to replace the preexisting in-house solution. A brief introduction to software quality practices is given, a description of the previous solution, the limitations of it and new upcoming requirements. Modifications required to adapt the new system are described, how these were implemented to current software and the results obtained. An overview on how the new system may be used in future projects is also presented.

  4. Structural thermal model tests on exposed facility of Japanese experiment module for international space station `Alpha`. 1st Report. Static load/fluid loop performance test and modal survey; Kokusai uchu station `Alpha` JEM bakurobu no netsukozo model shiken. 1. Seikaju shiken, ryudo tokusei shiken oyoboi modal survey

    Energy Technology Data Exchange (ETDEWEB)

    Mizuno, M.; Nakao, K.; Ikami, T.; Arafune, K.; Nakahara, S. [Ishikawajima-Harima Heavy Industries Co. Ltd., Tokyo (Japan)

    1995-03-01

    Static load/fluid loop performance test and modal survey results among structural thermal model (STM) tests of an exposed facility are reported for the Japanese Experiment Module (JEM) mounted on the international space station `Alpha`. In the static load test, the strength and rigidity of STM were ascertained to be reasonable against the loads applied to the facility at launch and reentry, and the structural mathematical model was also reasonable based on the comparison between test and analytical results. In the fluid performance test to verify the fundamental fluid loop performance of the thermal control system for the exposed facility, the test results on pressure losses of STM which has a strong effect on the accuracy of coolant fluid distribution at each branch point, well agreed with analytical ones. In the modal survey to verify dynamic characteristics of the structural mathematical model, some appropriate modal parameters were obtained by modal analysis of test data, and the survey results also well agreed with analytical ones on the structural mathematical model. 1 ref., 10 figs., 2 tabs.

  5. Model reduction for Space Station Freedom

    Science.gov (United States)

    Williams, Trevor

    1992-01-01

    Model reduction is an important practical problem in the control of flexible spacecraft, and a considerable amount of work has been carried out on this topic. Two of the best known methods developed are modal truncation and internal balancing. Modal truncation is simple to implement but can give poor results when the structure possesses clustered natural frequencies, as often occurs in practice. Balancing avoids this problem but has the disadvantages of high computational cost, possible numerical sensitivity problems, and no physical interpretation for the resulting balanced 'modes'. The purpose of this work is to examine the performance of the subsystem balancing technique developed by the investigator when tested on a realistic flexible space structure, in this case a model of the Permanently Manned Configuration (PMC) of Space Station Freedom. This method retains the desirable properties of standard balancing while overcoming the three difficulties listed above. It achieves this by first decomposing the structural model into subsystems of highly correlated modes. Each subsystem is approximately uncorrelated from all others, so balancing them separately and then combining yields comparable results to balancing the entire structure directly. The operation count reduction obtained by the new technique is considerable: a factor of roughly r(exp 2) if the system decomposes into r equal subsystems. Numerical accuracy is also improved significantly, as the matrices being operated on are of reduced dimension, and the modes of the reduced-order model now have a clear physical interpretation; they are, to first order, linear combinations of repeated-frequency modes.

  6. Corrective Action Investigation Plan for Corrective Action Unit 490: Station 44 Burn Area, Tonopah Test Range, Nevada (with Record of Technical Change No.1)

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, Nevada Operations Office

    2000-06-09

    This Corrective Action Investigation Plan (CAIP) contains the U.S. Department of Energy, Nevada Operations Office's approach to collect the data necessary to evaluate corrective action alternatives appropriate for the closure of Corrective Action Unit (CAU) 490 under the Federal Facility Agreement and Consent Order. Corrective Active Unit 490 consists of four Corrective Action Sites (CASs): 03-56-001-03BA, Fire Training Area (FTA); RG-56-001-RGBA, Station 44 Burn Area; 03-58-001-03FN, Sandia Service Yard; and 09-54-001-09L2, Gun Propellant Burn Area. These CASs are located at the Tonopah Test Range near Areas 3 and 9. Historically, the FTA was used for training exercises where tires and wood were ignited with diesel fuel. Records indicate that water and carbon dioxide were the only extinguishing agents used during these training exercises. The Station 44 Burn Area was used for fire training exercises and consisted of two wooden structures. The two burn areas (ignition of tires, wood, and wooden structures with diesel fuel and water) were limited to the building footprints (10 ft by 10 ft each). The Sandia Service Yard was used for storage (i.e., wood, tires, metal, electronic and office equipment, construction debris, and drums of oil/grease) from approximately 1979 to 1993. The Gun Propellant Burn Area was used from the 1960s to 1980s to burn excess artillery gun propellant, solid-fuel rocket motors, black powder, and deteriorated explosives; additionally, the area was used for the disposal of experimental explosive items. Based on site history, the focus of the field investigation activities will be to: (1) determine the presence of contaminants of potential concern (COPCs) at each CAS, (2) determine if any COPCs exceed field-screening levels and/or preliminary action levels, and (3) determine the nature and extent of contamination with enough certainty to support selection of corrective action alternatives for each CAS. The scope of this CAIP is to resolve

  7. The space station assembly phase: Flight telerobotic servicer feasibility, volume 1

    Science.gov (United States)

    Smith, Jeffrey H.; Gyamfi, Max A.; Volkmer, Kent; Zimmerman, Wayne F.

    1987-01-01

    The question is addressed which was raised by the Critical Evaluation Task Force (CETF) analysis of the space station: if a Flight Telerobotic Servicer (FTS) of a given technical risk could be built for use during space station assembly, could it save significant extravehicular (EVA) resources. Key issues and trade-offs associated with using an FTS to aid in space station assembly phase tasks such as construction and servicing are identified. A methodology is presented that incorporates assessment of candidate assembly phase tasks, telerobotics performance capabilities, development costs, operational constraints (STS and proximity operations), maintenance, attached payloads, and polar platforms. A discussion of the issues is presented with focus on potential FTS roles: (1) as a research-oriented test bed to learn more about space usage of telerobotics; (2) as a research-based test bed with an experimental demonstration orientation and limited assembly and servicing applications; or (3) as an operational system to augment EVA, to aid the construction of the space station, and to reduce the programmatic (schedule) risk by increasing the flexibility of mission operations. During the course of the study, the baseline configuration was modified into Phase 1 (a station assembled in 12 flights), and Phase 2 (a station assembled over a 30 flight period) configuration.

  8. Preliminary Sensorimotor and Cardiovascular Results from the Joint Russian and U.S. Pilot Field Test with Planning for the Full Field Test Beginning with the Year Long Intenational Space Station

    Science.gov (United States)

    Reschke, M. F.; Kozlovskaya, I. B.; Tomilovskaya, E. S.; Bloomberg, J. J.; Platts, S. H.; Rukavishnikov, I. V.; Fomina, E. V.; Stenger, M. B.; Lee, S. M. C.; Wood, S. J.; Mulavara, A. P.; Feiveson, A. H.; Cerisano, J. M.; Kofman, I. S.; Fisher, E. A.

    2014-01-01

    Ongoing collaborative research efforts between NASA's Neuroscience and Cardiovascular Laboratories, and the Institute of Biomedical Problems' (IBMP) Sensory-Motor and Countermeasures Laboratories have been measuring functional sensorimotor, cardiovascular and strength responses following bed rest, dry immersion, short duration (Space Shuttle) and long duration (Mir and International Space Station) space flights. While the unloading paradigms associated with dry immersion and bed rest does serve as acceptable flight analogs, testing of crew responses following the long duration flights previously has not been possible until a minimum of 24 hours after landing. As a result, it is not possible to estimate the nonlinear trend of the early (space flight crews beginning as soon after landing as possible (space flight.

  9. Flexible Laser Metal Cutting

    DEFF Research Database (Denmark)

    Villumsen, Sigurd; Jørgensen, Steffen Nordahl; Kristiansen, Morten

    2014-01-01

    This paper describes a new flexible and fast approach to laser cutting called ROBOCUT. Combined with CAD/CAM technology, laser cutting of metal provides the flexibility to perform one-of-a-kind cutting and hereby realises mass production of customised products. Today’s laser cutting techniques...... possess, despite their wide use in industry, limitations regarding speed and geometry. Research trends point towards remote laser cutting techniques which can improve speed and geometrical freedom and hereby the competitiveness of laser cutting compared to fixed-tool-based cutting technology...... such as punching. This paper presents the concepts and preliminary test results of the ROBOCUT laser cutting technology, a technology which potentially can revolutionise laser cutting....

  10. Development and Certification of Station Development Test Objective (SDTO) Experiment # 15012-U, "Near RealTime Water Quality Monitoring Demonstration for ISS Biocides Using Colorimetric Solid Phase Extraction (CSPE)"

    Science.gov (United States)

    Gazda, Daniel B.; Nolan, Daniel J.; Rutz, Jeffrey A.; Shcultz, John R.; Siperko, Lorraine M.; Porter, Marc D,; Lipert, Robert J.; Limardo, Jose G.; McCoy, J. Torin

    2009-01-01

    Scientists and engineers from the Wyle Integrated Science and Engineering Group are working with researchers at the University of Utah and Iowa State University to develop and certify an experimental water quality monitoring kit based on Colorimetric Solid Phase Extraction (CSPE). The kit will be launched as a Station Development Test Objective (SDTO) experiment and evaluated on the International Space Station (ISS) to determine the acceptability of CSPE technology for routine inflight water quality monitoring. Iodine and silver, the biocides used in the US and Russian on-orbit water systems, will serve as test analytes for the technology evaluation. This manuscript provides an overview of the CSPE SDTO experiment and details the development and certification of the experimental water quality monitoring kit. Initial results from reagent and standard solution stability testing and environmental testing performed on the kit hardware are also reported.

  11. Development and Certification of Station Development Test Objective (SDTO) Experiment # 15012-U, "Near RealTime Water Quality Monitoring Demonstration for ISS Biocides Using Colorimetric Solid Phase Extraction (CSPE)"

    Science.gov (United States)

    Gazda, Daniel B.; Nolan, Daniel J.; Rutz, Jeffrey A.; Shcultz, John R.; Siperko, Lorraine M.; Porter, Marc D,; Lipert, Robert J.; Limardo, Jose G.; McCoy, J. Torin

    2009-01-01

    Scientists and engineers from the Wyle Integrated Science and Engineering Group are working with researchers at the University of Utah and Iowa State University to develop and certify an experimental water quality monitoring kit based on Colorimetric Solid Phase Extraction (CSPE). The kit will be launched as a Station Development Test Objective (SDTO) experiment and evaluated on the International Space Station (ISS) to determine the acceptability of CSPE technology for routine inflight water quality monitoring. Iodine and silver, the biocides used in the US and Russian on-orbit water systems, will serve as test analytes for the technology evaluation. This manuscript provides an overview of the CSPE SDTO experiment and details the development and certification of the experimental water quality monitoring kit. Initial results from reagent and standard solution stability testing and environmental testing performed on the kit hardware are also reported.

  12. Microbiological Tests Performed During the Design of the International Space Station Environmental Control and Life Support Systems. Part 1, Bulk Phase. Part 1; Bulk Phase

    Science.gov (United States)

    Roman, Monsi C.; Mittelman, Marc W.

    2010-01-01

    The design and manufacturing of the main Environmental Control and Life Support Systems (ECLSS) for the United States segments of the International Space Station (ISS) was an involved process that started in the mid 1980s, with the assessment and testing of competing technologies that could be used to clean the air and recycle water. It culminated in 2009 with the delivery and successful activation of the Water Recovery System (WRS) water processor (WP). The ECLSS required the work of a team of engineers and scientist working together to develop systems that could clean and/or recycle human metabolic loads to maintain a clean atmosphere and provide the crew clean water. One of the main goals of the ECLSS is to minimize the time spent by the crew worrying about vital resources not available in the vacuum of space, which allows them to spend most of their time learning to live in a microgravity environment many miles from the comforts of Earth and working on science experiments. Microorganisms are a significant part of the human body as well as part of the environment that we live in. Therefore, the ISS ECLSS design had to take into account the effect microorganisms have on the quality of stored water and wastewater, as well as that of the air systems. Hardware performance issues impacted by the accumulation of biofilm and/or microbiologically influenced corrosion were also studied during the ECLSS development stages. Many of the tests that were performed had to take into account the unique aspects of a microgravity environment as well as the challenge of understanding how to design systems that could not be sterilized or maintained in a sterile state. This paper will summarize the work of several studies that were performed to assess the impacts and/or to minimize the effects of microorganisms in open, semi-closed and closed loop life support system. The biofilm and biodeterioration studies that were performed during the design and test periods will be presented in

  13. Implementation of Flexible Access System

    Science.gov (United States)

    Wu, Chen-Hsiang; Peng, Jan-Wen; Shao, Shou-Kuo; Chen, Tzooming E.; Chen, Shih Chang; Lee, Meng-Shu; Yen, K.-Y.; Chen, Tsung-Mao; Wang, Ching Sheu; Tu, Yuan-Kuang

    1998-06-01

    In this paper we present the architecture, operation, and the implementation of a prototype system, flexible access system (FAS), developed by CHT T.L. for FITL applications. FAS adopts fiber to the curb (FTTC) topology and provides POTS, ISDN BRA, and T1 services. The system consists of three main parts, namely, fiber central office terminal (FCOT) at switch side, fiber nodes (FN) at customer side, and a monitor station. FCOT and FNs are connected through an STM-1 fiber distribution ring. The hardware structure and the operation principle for each module are described. FAS contains the mux-demux module, POTS, ISDN, and T1 central office/customer service modules, operation modules, and power module. In the design, each central office service module in FCOT simulates as a CPE to terminate signals from switch, and will separate the data and signaling and map them into DS1 format. Mux/demux module will add/drop these DS1, put the operation information in data communication channel (DCC), and convert them to STM-1 optical link. Each customer service module in FN simulates switch line cart to regenerate the signal for customers. The prototype system implementation confirms the benefits of introducing SDH add/drop technologies to FITL system to provide basic telecommunication services. The design experience reveals that the clock synchronization method and noise reduction technique can significantly influence the performance in such a system. The test results that demonstrate and verify the designed functionality and the service quality of the prototype system will be presented.

  14. Flexible Ultrasonic Phased-Array Probe

    Institute of Scientific and Technical Information of China (English)

    施克仁; 阙开良; 郭大勇

    2004-01-01

    In ultrasonic phased-array testing, most probes are rigid with fixed elements. However, when testing a cambered piece, a rigid probe cannot be used directly, but an ultrasonic chock or coupling media must be used, which adds cost and reduces the accuracy. The objective of this research was to improve the tests of cambered pieces. A flexible ultrasonic phased-array probe was developed to do the flexible phased-array testing. The key technologies in the flexible phased-array probe include the probe design and the phased-array control. A new method was developed to design the flexible probe according to the curvature of the piece and the test depth. The method includes the calculation of the element's height (he), the relative rotation angle ((e), the distance between the adjoining elements (de), and the element's effective testing range. A flexible ultrasonic phased-array probe has been developed using this method.

  15. Differences Analysis on Domestic and Foreign Process Pipeline Pressure Testing Standards for Oil and Gas Transportation Stations%国内外输油气站工艺管道试压标准差异分析

    Institute of Scientific and Technical Information of China (English)

    余运复; 张继霞; 吴俊松; 于宏庆

    2014-01-01

    Domestic process pipeline pressure testing standards for oil and gas transportation stations were classified and assessed, with prompting the idea of adopting foreign standards to improve the domestic design and operating level of oil and gas transportation stations. The advancement of foreign process pipeline pressure testing standards for oil and gas transportation stations were systematacially expounded, including integration strength testing and leakage testing, or leakage testing alone for low operating pressure pipeline, and classification principle of process pipeline, and air inspection method and pressure reducing procedure during pressure testing, and pressure testing periods of process pipeline. In addition, advanced technology and construction cases of domestic and foreign process pipeline pressure testing for oil and gas transportation stations were also introduced, such as the determination of reasonable sustaining time based on leakage mathematical model, and the determination of air pressure testing damage radius based on high pressure air explosion energy calculation method, etc. Finally, by means of learning foreign standards, recommendations are made to raise the level of Chinese process pipeline pressure testing standards for oil and gas transportation stations.%梳理评价了国内输油气站工艺管道试压标准,提出了借鉴国外标准的先进理念,提高国内输油气站设计和运行水平的思路。国外输油气站工艺管道试压标准的先进性主要体现在以下几个方面:管道运行压力较低,强度试验和严密性试验合并进行,或者仅进行严密性试验;工艺管道划分原则;试压过程空气含量检测方法和降压程序;工艺管道试压周期等。此外还介绍了国内外关于输油气站工艺管道试压的先进技术和施工实例,包括利用严密性数学模型确定合理稳压时间;利用高压气体爆炸能量计算方法确定气试压损伤半径

  16. RCTS: A flexible environment for sensor integration and control of robot systems; the distributed processing approach

    Science.gov (United States)

    Allard, R.; Mack, B.; Bayoumi, M. M.

    1989-01-01

    Most robot systems lack a suitable hardware and software environment for the efficient research of new control and sensing schemes. Typically, engineers and researchers need to be experts in control, sensing, programming, communication and robotics in order to implement, integrate and test new ideas in a robot system. In order to reduce this time, the Robot Controller Test Station (RCTS) has been developed. It uses a modular hardware and software architecture allowing easy physical and functional reconfiguration of a robot. This is accomplished by emphasizing four major design goals: flexibility, portability, ease of use, and ease of modification. An enhanced distributed processing version of RCTS is described. It features an expanded and more flexible communication system design. Distributed processing results in the availability of more local computing power and retains the low cost of microprocessors. A large number of possible communication, control and sensing schemes can therefore be easily introduced and tested, using the same basic software structure.

  17. Test on Dynamic Response of Flexible Base Asphalt Pavement%柔性基层沥青路面动力响应试槽试验

    Institute of Scientific and Technical Information of China (English)

    李起伟; 黎晓; 梁乃兴

    2012-01-01

    根据室内试槽柔性基层沥青路面结构的重复加载试验,总结了路用电阻应变片的选择依据和黏贴工艺,对比分析了压路机压实方式对应变片存活率的影响;利用惠斯登电桥电路测试了柔性基层沥青路面的动力响应,并与数值计算进行对比.研究表明:路用电阻应变片栅长应大于80 mm,并与集料的最大公称粒径相关;电阻应变片在压路机静压的方式下有较理想的存活率,而在强振作用下却极难存活;在移动荷载作用下沥青面层底部横向应变交替出现拉、压应变,其最大值比层状弹性体系模型计算值小.%According to repeated load test of flexible base asphalt pavement, the structure is built in the indoor pit. The principle of choosing resistance strain gauges and the surface-sticking process of gauge was summarized; the survival rate of strain gauge based on the comparison of road roller' s compaction mode strong vibration or static pressure was discussed. The data of time-history curves was collected through the Wheatstone Bridge with the numerical calculation comparative study. The detection results show; the gate length of resistance strain gauge should not be less than 80mm, which is related to nominal maximum size of aggregate. Gauges' survival rate is affected by different compaction model, which is much lower under the strong vibration model. Also the response of. strain in layer bottom under the dynamic load of moving vehicle is more complex than that in static situation. However, the current pavement structure design method needs transforming from static model to dynamic load model.

  18. 适用于动静压试验的综合液压源的设计%A Multifunctional Pump Station Designed for Dynamic and Static Pressure Hydraulic Tests

    Institute of Scientific and Technical Information of China (English)

    孔炫畅

    2015-01-01

    分析了液压元件动静压试验的测试需求,据此进行了液压泵站的设计。液压泵站液压能由电动泵和手动泵提供,满足不同性质的液压实验需求。实践证明,对于实验类型较多,特别是静压实验较多的场合,综合液压源与常规液压源相比,具有明显优势。%Based on the dynamic and static pressure test requirement of hydraulic components, the pump station is designed. The hydraulic power of the pump station is provided by its motor pump and hand pump in accordance with different hydraulic tests. It is proved in practice that the pump station is more adequate than normal hydraulic power source to tests which need the hydraulic pressure to be hold for a long time, such as a leak test.

  19. Balance and flexibility.

    Science.gov (United States)

    2003-12-01

    The 'work-life balance' and flexible working are currently key buzz terms in the NHS. Those looking for more information on these topics should visit Flexibility at www.flexibility.co.uk for a host of resources designed to support new ways of working, including information on flexible workers and flexible rostering, the legal balancing act for work-life balance and home working.

  20. Digital modeling of radioactive and chemical waste transport in the aquifer underlying the Snake River Plain at the National Reactor Testing Station, Idaho

    Science.gov (United States)

    Robertson, J.B.

    1974-01-01

    Industrial and low-level radioactive liquid wastes at the National Reactor Testing Station (NRTS) in Idaho have been disposed to the Snake River Plain aquifer since 1952. Monitoring studies have indicated that tritium and chloride have dispersed over a 15-square mile (39-square kilometer) area of the aquifer in low but detectable concentrations and have only migrated as far as 5 miles (8 kilometers) downgradient from discharge points. The movement of cationic waste solutes, particularly 90Sr and 137Cs, has been significantly retarded due to sorption phenomena, principally ion exchange. 137Cs has shown no detectable migration in the aquifer and 90Sr has migrated only about 1.5 miles (2 kilometers) from the Idaho Chemical Processing Plant (ICPP) discharge well, and is detectable over an area of only 1.5 square miles ( 4 square kilometers) of the aquifer. Digital modeling techniques have been applied successfully to the analysis of the complex waste-transport system by utilizing numerical solution of the coupled equations of groundwater motion and mass transport. The model includes the effects of convective transport, flow divergence, two-dimensional hydraulic dispersion, radioactive decay, and reversible linear sorption. The hydraulic phase of the model uses the iterative, alternating direction, implicit finite-difference scheme to solve the groundwater flow equations, while the waste-transport phase uses a modified method of characteristics to solve the solute transport equations simulated by the model. The modeling results indicate that hydraulic dispersion (especially transverse) is a much more significant influence than previously suggested by earlier studies. The model has been used to estimate future waste migration patterns for varied assumed hydrological and waste conditions up through the year 2000. The hydraulic effects of recharge from the Big Lost River have an important (but not predominant) influence on the simulated future migration patterns. For the

  1. Structural Verification of the First Orbital Wonder of the World - The Structural Testing and Analysis of the International Space Station (ISS)

    Science.gov (United States)

    Zipay, John J.; Bernstein, Karen S.; Bruno, Erica E.; Deloo, Phillipe; Patin, Raymond

    2012-01-01

    The International Space Station (ISS) can be considered one of the structural engineering wonders of the world. On par with the World Trade Center, the Colossus of Rhodes, the Statue of Liberty, the Great Pyramids, the Petronas towers and the Burj Khalifa skyscraper of Dubai, the ambition and scope of the ISS structural design, verification and assembly effort is a truly global success story. With its on-orbit life projected to be from its beginning in 1998 to the year 2020 (and perhaps beyond), all of those who participated in its development can consider themselves part of an historic engineering achievement representing all of humanity. The structural design and verification of the ISS could be the subject of many scholarly papers. Several papers have been written on the structural dynamic characterization of the ISS once it was assembled on-orbit [1], but the ground-based activities required to assure structural integrity and structural life of the individual elements from delivery to orbit through assembly and planned on-orbit operations have never been totally summarized. This paper is intended to give the reader an overview of some of the key decisions made during the structural verification planning for the elements of the U.S. On-Orbit Segment (USOS) as well as to summarize the many structural tests and structural analyses that were performed on its major elements. An effort is made for this paper to be summarily comprehensive, but as with all knowledge capture efforts of this kind, there are bound to be errors of omission. Should the reader discover any of these, please feel free to contact the principal author. The ISS (Figure 1) is composed of pre-integrated truss segments and pressurized elements supplied by NASA, the Russian Federal Space Agency (RSA), the European Space Agency (ESA) and the Japanese Aerospace Exploration Agency (JAXA). Each of these elements was delivered to orbit by a launch vehicle and connected to one another either robotically or

  2. 中国青少年柔韧素质测试标准研究综述%The research summary of test standards on Chinese adolescents' flexibility quality

    Institute of Scientific and Technical Information of China (English)

    袁冬颖; 阎智力

    2012-01-01

    By using the method of document, comparative and comprehensive analysis. This paper comparison and analysis the development process, the test methods and the evaluation methods of youth flexibility quality in the United States, Japan and China. The results showed that Chinese youth flexibility quality research has a short history but rapid development, the test methods are lower effectiveness and there is no evaluation standard for Chinese youth. So the study of the flexibility quality test standard reform has great significance.%运用文献资料、对比研究、综合分析等研究方法,对美国、日本、中国青少年柔韧素质的发展过程、测试方法、评价方法三个方面进行了比较与分析,结果显示:我国青少年柔韧素质研究历史短,但发展迅速;测试方法有效性较低;没有制定出适合中国青少年的评价标准,因此,进行柔韧素质测试标准改革的研究具有重大意义。

  3. Automatic system of tests for control equipment in combined cycle power stations; Sistema automatico de pruebas para equipos de control en centrales de ciclo combinado

    Energy Technology Data Exchange (ETDEWEB)

    Martinez M, Miguel A; Flores L, Zenon; Delgadillo V, Miguel A; Gutierrez A, Ruben [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2001-07-01

    This article deals on the Automatic System of Tests, denominated PROBADOR, used by the Gerencia de Control e Instrumentation (GCI) of the Instituto de Investigaciones Electricas (IIE)for the accomplishment of dynamic tests in laboratory, to the systems of acquisition and control developed with the electronic line SAC-IIE that are installed in the Thermoelectric Power station of Combined Cycle (CTCC) of Dos Bocas, Veracruz and Gomez Palacio, Durango, Mexico. Also the architecture, the functions that are carried out in the equipment of the System of Acquisition and control (SAC) and in the personal computer (PC) that conforms it are described, as well as the methodology used for the development of the tests. The PC constitutes Interface Man-Machine (IMM) and in the SAC equipment the simulation of the processes is made (by means of the execution of algebraic-differential equations) in the compressor, combustion chamber, gas turbine, heat recuperators, steam turbines and condenser equipment that integrate a CTCC. The equations that are used are based in the thermodynamics, flow dynamics and heat transfer; they become attached to the real process with a margin of error that is estimated in 10%. Finally, the tendencies of the PROBADOR and the technical and economic advantages are described that it has provided for the improvement in the performance of the control systems, before different situations, with no need to have the real process. [Spanish] Este articulo versa sobre el Sistema Automatico de Pruebas, denominado PROBADOR, utilizado por la Gerencia de Control e Instrumentacion (GCI) del Instituto de Investigaciones Electricas para la realizacion de pruebas dinamicas en laboratorio, a los sistemas de adquisicion y control desarrollado con la linea electronica SAC-IIE que estan instalados en las Centrales Termoelectricas de Ciclo Combinado (CTCC) de Dos Bocas, Veracruz y Gomez Palacio, Durango, Mexico. Tambien se describen la arquitectura, las funciones que se llevan

  4. 超细干粉灭火系统应用于加油站火灾防控初探%Pre-test of Fire Prevention and Control of Gas Station Using Super Fine Powder Fire Extinguishing System

    Institute of Scientific and Technical Information of China (English)

    谢树俊; 宋文华; 丁旭东; 徐昕; 张俪昽

    2011-01-01

    Aiming at the fast spread speed and the strong fire behavior of gas station fire, the traditional mobile, cart-type dry powder and foam extinguishers can not meet the requirements of gas station fire safety situation. Based on "Code of design,Construction and Acceptance for Super fine powder extinguish system ","super fine powder fire extinguishing system design, construction and acceptance specification" and other related standards, combined with the gas station engineering design requirements and the characteristics of fire hazards, the design principles of gas station by using super fine powder fire extinguishing system for fire fighting and initial control was given. Take a gas station in Tianjin as an example, using the given design principles to the fire control system of its key fire danger area's design, the equipment selection and system capability evaluation were given. Under the given condition, compared with the gas station fire equipment based on the standards, design selection of super fine powder fire extinguishing facilities is equipped with simple, flexible and convenient advantages, and also remarkable extinguishing effect. It can also maximize the attack speed and minimizing the risk of fighting and casualties, the gas station's capability of prevention and control of sudden fire has been significantly upgraded.%针对加油站火灾起火速度快、火势猛,传统的手提、推车式干粉及泡沫灭火器不能满足加油站消防安全要求的实际情况,依据《汽车加油加气站设计与施工规范》、《超细干粉灭火系统设计、施工及验收规范》等相关标准,结合加油站工程设计的要求和火灾隐患的特点,给出加油站采用超细干粉灭火系统用于火灾扑救与初期控制时,设计应遵循的原则.以天津某加油站为例,利用给出的设计原则对其重点火灾隐患部位的消防系统进行了设计、设备选型与系统消防能力评估,在给定的条件下,选用超

  5. An Effective Fault Diagnosis Strategy of Test Point Optimization for Communication Radio Station%一种高效的通信电台测试点优化故障诊断策略

    Institute of Scientific and Technical Information of China (English)

    李文元; 闫海华; 姚宏杰

    2013-01-01

    For the problems of test diagnosis for communication radio stations,a method based on GADPSO and rule of maximum diagnosis information is presented to solve the fault diagnosis of communication radio stations by optimizing the test point' s fault-test matrix. As the genetic operator is introduced into the DPSO,the algorithm is used to find the optimum test points. By adopting maximum fault diagnosis information, test order can be selected based on the information. The result shows that the GADPSO has better computation efficiency and precision. The GADPSO not only avoids the local optimization and premature convergence,but also improves the searching efficiency. Rule of maximum diagnosis information can estimate test points and is fast and effective in finding the test order. It offers an efficient method for the fault diagnosis strategy of communication radio station.%针对通信电台的测试诊断问题,通过建立“故障-测试”相关性矩阵,提出了一种GADPSO算法与最大诊断信息量准则结合进行通信电台故障诊断的方法.GADPSO算法收敛速度快、计算精度高,既避免了陷入局部最优和早熟收敛,又提高了优化效率;最大诊断信息量准则能全面评判测试点,快速有效地获得测试顺序.该方法为通信电台故障诊断提供了一种高效诊断策略.

  6. Research and Realization of Test Technology for Energy Storage Station Interconnecting to Power Grid%储能电站并网测试技术研究与实现

    Institute of Scientific and Technical Information of China (English)

    陈彬; 汤奕; 鲁针针; 谭敏刚; 陶以彬

    2015-01-01

    随着储能技术及大型储能电站建设的不断发展,亟待对储能电站进行并网测试以保证其并网后安全运行。首先根据储能电站构成,分析了并网测试指标及具体测试方法;其次,在保证被测储能系统完整性的前提下,研制开发了储能电站并网一体化测试平台,并详细介绍了该平台的软硬件开发及功能设计方案;最后,基于测试平台工程应用场景,介绍了测试装置现场接线方式,提出了储能电站并网测试实施方案。实际工程应用表明了所提出的测试平台及测试方案的可行性。%With the continuous development of energy storage technology and the construction of large-scale energy storage power station,the test of energy storage station is necessary for further study to ensure the safety and normal operation after interconnecting to power grid.Firstly,test indicators and specific testing methods are analyzed based on the configuration of energy storage station.Then,an integrated test bench is developed based on the integrity of energy storage station and the interconnecting network.The hardware architecture and program structure of the proposed test bench and the function design are described in detail.Finally,according to the project scenario of test bench,the wiring diagram of test devices is described and the implementation of the test program is proposed.The practical application shows the feasibility of the proposed test bench and its supporting program.

  7. Application Trend of On-line Measuring and Testing Technology in Engine Plants Adopted Flexible Production Model%汽车发动机厂柔性生产方式下的现场检测技术

    Institute of Scientific and Technical Information of China (English)

    朱正德

    2012-01-01

    The paper points out that modern plants must adopt a multi-line production, namely flexible production model to meet the car market demand of diversity products, especially for power train plants. It is well known that on-line measuring and test technology is an important part of the manufacturing technology. Therefore, in order to acclimatize to flexible production, online testing technique and equipment should possess some features, including flexible inspection between process, Coordinate measuring machine (CMM) in the production site, establishing exclusive measuring room and general utilization and flexible gauge. The paper introduces and explains based on a series of targeted examples.%为满足轿车市场对产品需求的多样性,现代企业必须采取多品种混线生产,即柔性化生产模式,尤其对于动力总成类企业。众所周知,检测技术是制造工艺的一个重要组成。据此,文章提出为适应柔性化生产,在线检测工艺与装备需要具备的一些特点,如:工序间检验夹具的柔性化、坐标测量机配置在生产现场、建立专用的生产测量室以及量规的通用化和柔性化等。文章通过针对性的实例进行了介绍和说明。

  8. Easy and flexible mixture distributions

    DEFF Research Database (Denmark)

    Fosgerau, Mogens; Mabit, Stefan L.

    2013-01-01

    We propose a method to generate flexible mixture distributions that are useful for estimating models such as the mixed logit model using simulation. The method is easy to implement, yet it can approximate essentially any mixture distribution. We test it with good results in a simulation study...

  9. 核电站主回路系统主要设备的射线透照工艺%Radiographic Process for Main Equipment of Nuclear Power Station Primary System in Radiographic Testing

    Institute of Scientific and Technical Information of China (English)

    华雄飞; 毛羽飞; 张铁辉; 李金强; 梅义俊; 刘顺

    2012-01-01

    Primary system of nuclear power station is the main examination object of radiographic testing in PSI/ ISI. Starting with radiography process in radiographic testing, radiography process and implementation of main equipment as steam generator ( SG ), reactor pressure vessel ( RPV ) and pressurizer ( PRZ ) were introduced quite systematic in primary system of nuclear power station. Radiographic special tools used in each exposure were presented also. Based on the successful experience of pre-service inspection in Ling'ao No. 3 and 4 nuclear power station, foundation is laid for the PSI/ISI later.%核电站主回路系统是核电站役前/在役检查的主要检测对象,从射线检测透照工艺入手,系统地介绍了核电站主回路系统主要设备蒸汽发生器SG、反应堆压力容器RPV以及稳压器PRZ的透照方式及实施方法,并对各透照中所使用的专用工具架做了介绍。以岭澳核电站3,4号机组役前检查顺利完成的实际经验为依托,为以后役前/在役检查打下基础。

  10. Numerical Simulation and Validation Test of Air Age in Pressurization Room of Space Station%空间站密封舱空气龄分布数值模拟及试验研究

    Institute of Scientific and Technical Information of China (English)

    裴一飞; 苏新明

    2012-01-01

    The theory of air age was introduced. The effect of air age in pressurization room air quality evaluation of space station was discussed. Research progress of numerical simulation and validation test of air age distribution in pressurization room of space station domestic and abroad was summarized. Suggestions were put forward for numerical simulation and validation test of air age in pressurization room of space station.%介绍了空气龄理论,阐述了空气龄在空间站密封舱内空气品质评价方面的作用,对国内外在空间站密封舱内空气龄数值模拟、空气龄分布验证试验的研究进展进行了综述,并给出了对空间站密封舱进行空气龄数值模拟及试验研究的建议.

  11. BASE Flexible Array Preliminary Lithospheric Structure Analysis

    Science.gov (United States)

    Yeck, W. L.; Sheehan, A. F.; Anderson, M. L.; Siddoway, C. S.; Erslev, E.; Harder, S. H.; Miller, K. C.

    2009-12-01

    The Bighorns Arch Seismic Experiment (BASE) is a Flexible Array experiment integrated with EarthScope. The goal of BASE is to develop a better understanding of how basement-involved foreland arches form and what their link is to plate tectonic processes. To achieve this goal, the crustal structure under the Bighorn Mountain range, Bighorn Basin, and Powder River Basin of northern Wyoming and southern Montana are investigated through the deployment of 35 broadband seismometers, 200 short period seismometers, 1600 “Texan” instruments using active sources and 800 “Texan” instruments monitoring passive sources, together with field structural analysis of brittle structures. The novel combination of these approaches and anticipated simultaneous data inversion will give a detailed structural crustal image of the Bighorn region at all levels of the crust. Four models have been proposed for the formation of the Bighorn foreland arch: subhorizontal detachment within the crust, lithospheric buckling, pure shear lithospheric thickening, and fault blocks defined by lithosphere-penetrating thrust faults. During the summer of 2009, we deployed 35 broadband instruments, which have already recorded several magnitude 7+ teleseismic events. Through P wave receiver function analysis of these 35 stations folded in with many EarthScope Transportable Array stations in the region, we present a preliminary map of the Mohorovicic discontinuity. This crustal map is our first test of how the unique Moho geometries predicted by the four hypothesized models of basement involved arches fit seismic observations for the Bighorn Mountains. In addition, shear-wave splitting analysis for our first few recorded teleseisms helps us determine if strong lithospheric deformation is preserved under the range. These analyses help lead us to our final goal, a complete 4D (3D spatial plus temporal) lithospheric-scale model of arch formation which will advance our understanding of the mechanisms

  12. A novel flexible clinical multiphoton tomograph for early melanoma detection, skin analysis, testing of anti-age products, and in situ nanoparticle tracking

    Science.gov (United States)

    Weinigel, Martin; Breunig, Hans Georg; Gregory, Axel; Fischer, Peter; Kellner-Höfer, Marcel; Bückle, Rainer; König, Karsten

    2010-02-01

    High-resolution 3D microscopy based on multiphoton induced autofluorescence and second harmonic generation have been introduced in 1990. 13 years later, CE-marked clinical multiphoton systems for 3D imaging of human skin with subcellular resolution have first been launched by JenLab company with the tomography DermaInspect®. This year, the second generation of clinical multiphoton tomographs was introduced. The novel multiphoton tomograph MPTflex, equipped with a flexible articulated optical arm, provides an increased flexibility and accessibility especially for clinical and cosmetical examinations. Improved image quality and signal to noise ratio (SNR) are achieved by a very short source-drain spacing, by larger active areas of the detectors and by single photon counting (SPC) technology. Shorter image acquisition time due to improved image quality reduces artifacts and simplifies the operation of the system. The compact folded optical design and the light-weight structure of the optical head eases the handling. Dual channel detectors enable to distinguish between intratissue elastic fibers and collagenous structures simultaneously. Through the use of piezo-driven optics a stack of optical cross-sections (optical sectioning) can be acquired and 3D imaging can be performed. The multiphoton excitation of biomolecules like NAD(P)H, flavins, porphyrins, elastin, and melanin is done by picojoule femtosecond laser pulses from an tunable turn-key femtosescond near infrared laser system. The ability for rapid high-quality image acquisition, the user-friendly operation of the system and the compact and flexible design qualifies this system to be used for melanoma detection, diagnostics of dermatological disorders, cosmetic research and skin aging measurements as well as in situ drug monitoring and animal research.

  13. Comparison Between Stress Obtained by Numerical Analysis and In-Situ Measurements on a Flexible Pipe Subjected to In-Plane Bending Test

    DEFF Research Database (Denmark)

    Vestergaard Lukassen, Troels; Glejbøl, Kristian; Lyckegaard, Anders

    2016-01-01

    variations will allow for performance optimization of the armour layers. To study the detailed stress variations in flexible pipes during dynamic loading, a comprehensive three-dimensional implicit nonlinear finite element model has been developed. The predicted numerical stress variations will be compared......To predict the lifetime and long-term properties of tensile armour wires in a dynamically loaded pipe, it is essential to have a tool which allows detailed prediction of the stress variations in the tensile armour wires during global pipe loading. Furthermore, detailed understanding of the stress...

  14. Strength, flexibility, and maturity in adolescent athletes.

    Science.gov (United States)

    Pratt, M

    1989-05-01

    The relationship between lower-extremity strength and flexibility and maturational status as measured by Tanner staging (TS) was assessed in 84 male high school athletes. The sum of one-repetition maximum lifts for knee extension and flexion was determined and flexibility was measured with the American Alliance of Health, Physical Education, Recreation, and Dance sit-and-reach test. Chronologic age, body weight, and percent fat were also recorded. Strength and flexibility were compared for each maturational and chronologic age category. Maturational age was better correlated with strength and flexibility than was chronologic age. All correlations were significant. Multiple regression analysis demonstrated significant correlations of TS and age with strength and flexibility. Tanner staging had greater predictive value than age for strength and flexibility. After adjusting for age, the relationship between TS and strength remained significant.

  15. Fire Stations - 2007

    Data.gov (United States)

    Kansas Data Access and Support Center — Fire Station Locations in Kansas Any location where fire fighters are stationed at or based out of, or where equipment that such personnel use in carrying out their...

  16. Big Game Reporting Stations

    Data.gov (United States)

    Vermont Center for Geographic Information — Point locations of big game reporting stations. Big game reporting stations are places where hunters can legally report harvested deer, bear, or turkey. These are...

  17. Water Level Station History

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Images contain station history information for 175 stations in the National Water Level Observation Network (NWLON). The NWLON is a network of long-term,...

  18. Streamflow Gaging Stations

    Data.gov (United States)

    Department of Homeland Security — This map layer shows selected streamflow gaging stations of the United States, Puerto Rico, and the U.S. Virgin Islands, in 2013. Gaging stations, or gages, measure...

  19. Hammond Bay Biological Station

    Data.gov (United States)

    Federal Laboratory Consortium — Hammond Bay Biological Station (HBBS), located near Millersburg, Michigan, is a field station of the USGS Great Lakes Science Center (GLSC). HBBS was established by...

  20. Fire Stations - 2009

    Data.gov (United States)

    Kansas Data Access and Support Center — Fire Stations in Kansas Any location where fire fighters are stationed or based out of, or where equipment that such personnel use in carrying out their jobs is...

  1. Capacity at Railway Stations

    DEFF Research Database (Denmark)

    Landex, Alex

    2011-01-01

    Stations do have other challenges regarding capacity than open lines as it is here the traffic is dispatched. The UIC 406 capacity method that can be used to analyse the capacity consumption can be exposed in different ways at stations which may lead to different results. Therefore, stations need...... special focus when conducting UIC 406 capacity analyses.This paper describes how the UIC 406 capacity method can be expounded for stations. Commonly for the analyses of the stations it is recommended to include the entire station including the switch zone(s) and all station tracks. By including the switch...... is changed, this paper recommends that the railway lines are not always be divided. In case trains turn around on open (single track) line, the capacity consumption may be too low if a railway line is divided. The same can be the case if only few trains are overtaken at an overtaking station. For dead end...

  2. Weather Radar Stations

    Data.gov (United States)

    Department of Homeland Security — These data represent Next-Generation Radar (NEXRAD) and Terminal Doppler Weather Radar (TDWR) weather radar stations within the US. The NEXRAD radar stations are...

  3. Reference Climatological Stations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Reference Climatological Stations (RCS) network represents the first effort by NOAA to create and maintain a nationwide network of stations located only in areas...

  4. Newport Research Station

    Data.gov (United States)

    Federal Laboratory Consortium — The Newport Research Station is the Center's only ocean-port research facility. This station is located at Oregon State University's Hatfield Marine Science Center,...

  5. Station Climatic Summaries, Asia

    Science.gov (United States)

    1989-07-01

    OCDS) ................................................... 077 BIRJAND 408090 8612 (OCDS) ............................................. ( 381 BUSHEHR...ALL HOURS # 2 1 0 1 0 # 0 # 1 # 1 1 CACECR-IB 080 OPERATIONAL CLIMATIC DATA SUMM ARY STATION: BIRJAND , IRAN STATION #: 408090 ICAO ID...082. L@ OPERATIONAL CLIMATIC DATA SIJ44ARY STATION: BIRJAND , IRAN STATION #: 408090 ICAO ID: OIMB LOCATION: 32054’N, 59016’E ELEVATION (FEET): 4823 LST

  6. Inter-vertebral flexibility of the ostrich neck: implications for estimating sauropod neck flexibility.

    Directory of Open Access Journals (Sweden)

    Matthew J Cobley

    Full Text Available The flexibility and posture of the neck in sauropod dinosaurs has long been contentious. Improved constraints on sauropod neck function will have major implications for what we know of their foraging strategies, ecology and overall biology. Several hypotheses have been proposed, based primarily on osteological data, suggesting different degrees of neck flexibility. This study attempts to assess the effects of reconstructed soft tissues on sauropod neck flexibility through systematic removal of muscle groups and measures of flexibility of the neck in a living analogue, the ostrich (Struthio camelus. The possible effect of cartilage on flexibility is also examined, as this was previously overlooked in osteological estimates of sauropod neck function. These comparisons show that soft tissues are likely to have limited the flexibility of the neck beyond the limits suggested by osteology alone. In addition, the inferred presence of cartilage, and varying the inter-vertebral spacing within the synovial capsule, also affect neck flexibility. One hypothesis proposed that flexibility is constrained by requiring a minimum overlap between successive zygapophyses equivalent to 50% of zygapophyseal articular surface length (ONP50. This assumption is tested by comparing the maximum flexibility of the articulated cervical column in ONP50 and the flexibility of the complete neck with all tissues intact. It is found that this model does not adequately convey the pattern of flexibility in the ostrich neck, suggesting that the ONP50 model may not be useful in determining neck function if considered in isolation from myological and other soft tissue data.

  7. Using the DAS-ELISA Test to Establish an Effective Distance Between Bait Stations for Control of Linepithema humile (Hymenoptera: Formicidae) in Natural Areas.

    Science.gov (United States)

    Song, Jinbo; Benson, Eric P; Zungoli, Patricia A; Gerard, Patrick; Scott, Simon W

    2015-08-01

    Linepithema humile (Mayr), the Argentine ant, is an invasive pest that has spread throughout the United States and is a problem in natural and managed habitats in South Carolina. Foraging patterns and the effectiveness of liquid baits for control of this pest have been studied in urban areas. However, similar studies have not been conducted in natural areas such as parks, picnic grounds, or campsites. L. humile populations can be large and widespread, making them a major nuisance pest for visitors to these natural areas. The primary objective of this study was to determine an effective distance between bait stations for control of L. humile in a natural area. A double antibody-sandwich enzyme-linked immunosorbent assay (DAS-ELISA) procedure was used to detect individual ants that consumed rabbit immunoglobin (IgG) protein for marking and tracking. In both lab and field conditions, there was a significant difference in the detection of IgG in ants fed protein marker mixed with sugar water compared with ants only fed sugar water. Additional field studies revealed that an individual ant could retain detectable levels of protein marker for 3 d and that an ant feeding on IgG containing bait could be detected over 15 m from the original bait source. Overall, we found that using liquid ant baits, with a placement of 20 m between stations, was effective in reducing L. humile numbers between April to October, 2012 in a natural park area of Lake Greenwood State Park, SC. © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Jet engine test stand and soil stockpile. 107th fighter-interceptor group Niagara Falls Air Force Reserve Station, New York Air National Guard, Niagara Falls, New York. Final site assessment addendum report, 9-12 February 1993

    Energy Technology Data Exchange (ETDEWEB)

    1994-03-01

    THis report outlines additional site assessment activities which were conducted at the Jet Engine Test Stand (JETS), Building No. 852 located at the 197th Fighter-Interceptor Group, Niagara Falls Air National Guard Station (NFANGS), Air Force Reserve Facility (AFRF) approximately 6 miles northeast of Niagara Falls, New York (Figure 1.1). The additional site assessment activities were performed in response to requests, dated February 9 and 12, 1993, by the New York State Department of Environmental Conservation (NYSDEC) to further investigate contaminated soil and groundwater conditions at the JETS and at an existing soil stockpile (Appendix A).

  9. 安砂水力发电厂进水压力钢管安全检测与评定%Safty Testing and Evaluation of Steel Penstock in Hydropower Station

    Institute of Scientific and Technical Information of China (English)

    叶建建; 王星; 潘利坦

    2014-01-01

    阐述水电站进水压力钢管安全检测与评估的内容和方法,结合安砂水力发电厂工程实例,通过外观检测、腐蚀状况检测、超声波检测、材质检测、结构应力有限元分析与计算、应力检测一系列的检测方法,对安砂水力发电厂的进水压力钢管进行全面的安全检测和评估。%Contents and method of safty testing and evaluation of steel penstock in hydropower station are explained. A comprehensive safty inspection and evaluation of steel penstock are performed in Ansha Hydropower Station,by using a se-ries of methods of appearance inspection,corrosion detection,ultrasonic testing,material elements testing,structural stress finite element analysis,stress measurement.

  10. Image quality assessment of a 1.5T dedicated magnetic resonance-simulator for radiotherapy with a flexible radio frequency coil setting using the standard American College of Radiology magnetic resonance imaging phantom test.

    Science.gov (United States)

    Wong, Oi Lei; Yuan, Jing; Yu, Siu Ki; Cheung, Kin Yin

    2017-04-01

    A flexible RF coil setting has to be used on an MR-simulator (MR-sim) in the head and neck simulation scan for radiotherapy (RT) purpose, while the image quality might be compromised due to the sub-optimized flexible coil compared to the normal diagnostic radiological (DR) head coil. In this study, we assessed the image quality of an MR-sim by conducting the standard American College of Radiology (ACR) MRI phantom test on a 1.5T MR-sim under RT-setting and comparing it to DR-setting. A large ACR MRI phantom was carefully positioned, aligned and scanned 9 times for each under RT- and DR-setting on a 1.5T MR-sim, following the ACR scanning instruction. Images were analyzed following the ACR guidance. Measurement results under two coil settings were quantitatively compared. Inter-observer disagreements under RT-setting between two physicists were compared using Bland-Altman (BA) analysis and intra-class correlation coefficient (ICC). The MR-sim with RT-setting obtained sufficiently good image quality to pass all ACR recommended criteria. No significant difference was found in phantom length accuracy, high-contrast spatial resolution, slice thickness accuracy, slice position accuracy, and percent-signal ghosting. RT-setting significantly under-performed in low-contrast object detectability, while better performed in image intensity uniformity. BA analysis showed that 95% limit of agreement and biases of phantom test measurement under RT-setting between two observers were very small. Excellent inter-observer agreement (ICC >0.75) was achieved in all measurements except for slice thickness accuracy (ICC =0.42, moderate agreement) under RT-setting. Very good and highly reproducible image quality could be achieved on a 1.5T MR-sim with a flexible coil setting as revealed by the standard ACR MRI phantom test. The flexible RT-setting compromised in image signal-to-noise ratio (SNR) compared to the normal DR-setting, and resulted in reduced low-contrast object detectability.

  11. Fully Integral, Flexible Composite Driveshaft Project

    Data.gov (United States)

    National Aeronautics and Space Administration — An all-composite driveshaft incorporating integral flexible diaphragms is described and proposed for phase II prime conractor testing. The approach obsoletes the...

  12. Invertible flexible matrices

    Science.gov (United States)

    Justino, Júlia

    2017-06-01

    Matrices with coefficients having uncertainties of type o (.) or O (.), called flexible matrices, are studied from the point of view of nonstandard analysis. The uncertainties of the afore-mentioned kind will be given in the form of the so-called neutrices, for instance the set of all infinitesimals. Since flexible matrices have uncertainties in their coefficients, it is not possible to define the identity matrix in an unique way and so the notion of spectral identity matrix arises. Not all nonsingular flexible matrices can be turned into a spectral identity matrix using Gauss-Jordan elimination method, implying that that not all nonsingular flexible matrices have the inverse matrix. Under certain conditions upon the size of the uncertainties appearing in a nonsingular flexible matrix, a general theorem concerning the boundaries of its minors is presented which guarantees the existence of the inverse matrix of a nonsingular flexible matrix.

  13. Global Sourcing Flexibility

    DEFF Research Database (Denmark)

    Ørberg Jensen, Peter D.; Petersen, Bent

    2013-01-01

    sourcing flexibility. Here we draw on prior research in the fields of organizational flexibility, international business and global sourcing as well as case examples and secondary studies. In the second part of the paper, we discuss the implications of global sourcing flexibility for firm strategy......Recent studies show that flexibility is a key concern for firms that engage in the global sourcing of services. In this conceptual paper, we seek to explore two central aspects of global sourcing flexibility: In the first part of the paper, we provide a definition of the construct of global...... and operations against the backdrop of the theory-based definition of the construct. We discuss in particular the importance of global sourcing flexibility for operational performance stability, and the trade-off between specialization benefits, emerging from location and service provider specialization, versus...

  14. Damping Properties of Flexible Epoxy Resin

    Institute of Scientific and Technical Information of China (English)

    WANG Xiang; LIU Hanxing; OUYANG Shixi

    2008-01-01

    Amino-terminated polyethers and amino-terminated polyurethane were used as curing agent to cure the epoxy resin together and get a series of cured products. The damping properties of the composites were studied by DMA test at different measurement frequencies. Damping mechanical tests show that the flexible epoxy resin has higher loss factor than common epoxy. The highest loss factor reaches 1.57. Also the height and position of loss factor peak of the flexible epoxy resin varies by changing the content of amino-terminated polyethers. Results shows that the flexible epoxy resin can be used as damping polymer materials at room temperature or in common frequency range.

  15. Non-Coop Station History

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Station history documentation for stations outside the US Cooperative Observer network. Primarily National Weather Service stations assigned WBAN station IDs. Other...

  16. Call centres: constructing flexibility

    OpenAIRE

    Arzbächer, Sandra; Holtgrewe, Ursula; Kerst, Christian

    2002-01-01

    "The development of call centres as a flexible interface between firms and their environments has been seen as exemplary or even symptomatic of flexible capitalism (Sennett 1998). We are going to point out that they do not just stand for organisational change but also for changes of institutions towards deregulation. Employers and managers hoped for gains of flexibility, decreasing labour costs, and market gains by an expanded 24-hour-service. Surveillance and control by flexib...

  17. Pneumatic flexible shaft couplings

    OpenAIRE

    2007-01-01

    Main effort of every design engineer is reduction of torsional oscillation in any mechanical system. At present this problem can be solved by means of a suitable modification of dynamic properties of flexible shaft couplings according to dynamics in the given systems. But the dynamic properties of nowadays-applied flexible couplings arenot unchangeable because of aging and fatigue processes occurring in flexible coupling elements. Result of this fact causes detuning of mechanical system. Taki...

  18. Space station, 1959 to . .

    Science.gov (United States)

    Butler, G. V.

    1981-04-01

    Early space station designs are considered, taking into account Herman Oberth's first space station, the London Daily Mail Study, the first major space station design developed during the moon mission, and the Manned Orbiting Laboratory Program of DOD. Attention is given to Skylab, new space station studies, the Shuttle and Spacelab, communication satellites, solar power satellites, a 30 meter diameter radiometer for geological measurements and agricultural assessments, the mining of the moons, and questions of international cooperation. It is thought to be very probable that there will be very large space stations at some time in the future. However, for the more immediate future a step-by-step development that will start with Spacelab stations of 3-4 men is envisaged.

  19. Cooperative Station History Forms

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Various forms, photographs and correspondence documenting the history of Cooperative station instrumentation, location changes, inspections, and...

  20. Amtrak Rail Stations (National)

    Data.gov (United States)

    Department of Transportation — Updated database of the Federal Railroad Administration's (FRA) Amtrak Station database. This database is a geographic data set containing Amtrak intercity railroad...

  1. Flexible armored blanket development

    Energy Technology Data Exchange (ETDEWEB)

    Roth, E.S.

    1978-05-01

    An exploratory development contract was undertaken on December 23, 1977 which had as its purpose the development and demonstration of a flexible armored blanket design suitable for providing ballistic protection to nuclear weapons during shipment. Objectives were to design and fabricate a prototype blanket which will conform to the weapon shape, is troop-handleable in the field, and which, singly or in multiple layers, can defeat a range of kinetic energy armor piercing (AP) ammunition potentially capable of damaging the critical portion of the nuclear weapon. Following empirical testing, including the firing of threat ammunition under controlled laboratory and field test conditions, materials were selected and assembled into two blanket designs, each weighing approximately 54 kg/m{sup 2} (11 lbs/ft{sup 2}) and estimated to cost from $111 to $180 per ft{sup 2} in production. A firing demonstration to evidence blanket performance against terrorist/light infantry weapons, heavy infantry weapons, and aircraft cannon was conducted for representatives of the DOD and interested Sandia employees on April 12, 1978. The blankets performed better than anticipated defeating bullets up to 7.62 mm x 51 mm AP with one layer and projectiles up to 23 mm HEI with two layers. Based on these preliminary tests it is recommended that development work be continued with the following objectives: (1) the selection by the DOD of priority applications, (2) the specific design and fabrication of sufficient quantities of armored blankets for field testing, (3) the evaluation of the blankets by DOD operational units, with reports to Sandia Laboratories to enable final design.

  2. MULTI-FLEXIBLE SYSTEM DYNAMIC MODELING THEORY AND APPLICATION

    Institute of Scientific and Technical Information of China (English)

    仲昕; 周兵; 杨汝清

    2001-01-01

    The flexible body modeling theory was demonstrated. An example of modeling a kind of automobile's front suspension as a multi-flexible system was shown. Finally, it shows that the simulation results of multi-flexible dynamic model more approach the road test data than those of multi-rigid dynamic model do. Thus, it is fully testified that using multi-flexible body theory to model is necessary and effective.

  3. Reversibly Bistable Flexible Electronics

    KAUST Repository

    Alfaraj, Nasir

    2015-05-01

    Introducing the notion of transformational silicon electronics has paved the way for integrating various applications with silicon-based, modern, high-performance electronic circuits that are mechanically flexible and optically semitransparent. While maintaining large-scale production and prototyping rapidity, this flexible and translucent scheme demonstrates the potential to transform conventionally stiff electronic devices into thin and foldable ones without compromising long-term performance and reliability. In this work, we report on the fabrication and characterization of reversibly bistable flexible electronic switches that utilize flexible n-channel metal-oxide-semiconductor field-effect transistors. The transistors are fabricated initially on rigid (100) silicon substrates before they are peeled off. They can be used to control flexible batches of light-emitting diodes, demonstrating both the relative ease of scaling at minimum cost and maximum reliability and the feasibility of integration. The peeled-off silicon fabric is about 25 µm thick. The fabricated devices are transferred to a reversibly bistable flexible platform through which, for example, a flexible smartphone can be wrapped around a user’s wrist and can also be set back to its original mechanical position. Buckling and cyclic bending of such host platforms brings a completely new dimension to the development of flexible electronics, especially rollable displays.

  4. Organizational flexibility estimation

    OpenAIRE

    Komarynets, Sofia

    2013-01-01

    By the help of parametric estimation the evaluation scale of organizational flexibility and its parameters was formed. Definite degrees of organizational flexibility and its parameters for the Lviv region enterprises were determined. Grouping of the enterprises under the existing scale was carried out. Special recommendations to correct the enterprises behaviour were given.

  5. Flexible magnetoimpidence sensor

    KAUST Repository

    Kavaldzhiev, Mincho

    2015-05-01

    Recently, flexible electronic devices have attracted increasing interest, due to the opportunities they promise for new applications such as wearable devices, where the components are required to flex during normal use[1]. In this light, different magnetic sensors, like microcoil, spin valve, giant magnetoresistance (GMR), magnetoimpedance (MI), have been studied previously on flexible substrates.

  6. Flexible 'zoning' aids adaptability.

    Science.gov (United States)

    Corben, Simon

    2013-09-01

    Simon Corben, business development director at Capita Symonds' Health team, examines how 'clever use of zoning' when planning new healthcare facilities could improve hospital design, increase inherent flexibility, and reduce lifetime costs, and argues that a 'loose-fit, non-bespoke approach' to space planning will lead to 'more flexible buildings that are suitable for conversion to alternative uses'.

  7. Flexible ferroelectric organic crystals

    Science.gov (United States)

    Owczarek, Magdalena; Hujsak, Karl A.; Ferris, Daniel P.; Prokofjevs, Aleksandrs; Majerz, Irena; Szklarz, Przemysław; Zhang, Huacheng; Sarjeant, Amy A.; Stern, Charlotte L.; Jakubas, Ryszard; Hong, Seungbum; Dravid, Vinayak P.; Stoddart, J. Fraser

    2016-10-01

    Flexible organic materials possessing useful electrical properties, such as ferroelectricity, are of crucial importance in the engineering of electronic devices. Up until now, however, only ferroelectric polymers have intrinsically met this flexibility requirement, leaving small-molecule organic ferroelectrics with room for improvement. Since both flexibility and ferroelectricity are rare properties on their own, combining them in one crystalline organic material is challenging. Herein, we report that trisubstituted haloimidazoles not only display ferroelectricity and piezoelectricity--the properties that originate from their non-centrosymmetric crystal lattice--but also lend their crystalline mechanical properties to fine-tuning in a controllable manner by disrupting the weak halogen bonds between the molecules. This element of control makes it possible to deliver another unique and highly desirable property, namely crystal flexibility. Moreover, the electrical properties are maintained in the flexible crystals.

  8. Flexible ferroelectric organic crystals

    Science.gov (United States)

    Owczarek, Magdalena; Hujsak, Karl A.; Ferris, Daniel P.; Prokofjevs, Aleksandrs; Majerz, Irena; Szklarz, Przemysław; Zhang, Huacheng; Sarjeant, Amy A.; Stern, Charlotte L.; Jakubas, Ryszard; Hong, Seungbum; Dravid, Vinayak P.; Stoddart, J. Fraser

    2016-01-01

    Flexible organic materials possessing useful electrical properties, such as ferroelectricity, are of crucial importance in the engineering of electronic devices. Up until now, however, only ferroelectric polymers have intrinsically met this flexibility requirement, leaving small-molecule organic ferroelectrics with room for improvement. Since both flexibility and ferroelectricity are rare properties on their own, combining them in one crystalline organic material is challenging. Herein, we report that trisubstituted haloimidazoles not only display ferroelectricity and piezoelectricity—the properties that originate from their non-centrosymmetric crystal lattice—but also lend their crystalline mechanical properties to fine-tuning in a controllable manner by disrupting the weak halogen bonds between the molecules. This element of control makes it possible to deliver another unique and highly desirable property, namely crystal flexibility. Moreover, the electrical properties are maintained in the flexible crystals. PMID:27734829

  9. Space station resistojet system requirements and interface definition study

    Science.gov (United States)

    Heckert, Bruce J.

    1987-01-01

    Preliminary resistojet design requirements were established based on initial technical requirements imposed by the results of NASA and Rocketdyne studies. The requirements are directed toward long life, simplicity, flexibility, and commonality with other space station components. The resistojet assembly is comprised of eight resistojets, fluid components downstream of the waste fluid storage system, a power controller, structure, and shielding. It consists of two identical subassemblies, one of which is redundant. Each subassembly consists of four 500-W resistojets, series redundant latch values, a power controller, a water vaporizer, two pressure regulators, filters, check valves, disconnects, fluid tubing, and electrical cables. All components are packaged at the end of the stinger aft of the JEM and Columbus modules. Different flow and power control methods were studied. A constant inlet pressure and a two-power setting controller were tentatively selected based on simplicity and reasonably high specific impulse for the range of waste gas compositions that are anticipated. The constant pressure is supplied by pressure regulators. The two set point power control includes individual power supplies to each resistojet heater and water vaporizer. An embedded data processor, a multiplexer-demultiplexer, and a network interface unit that are standard space station components are included in the power controller. The total dry weight of the resistojet assembly is approximately 172 lb. The total cost for design, development, test, evaluation, qualification, and flight hardware is estimated to be $16 million.

  10. Vibration testing and analysis based on DASP of pump station pressure pipe line%基于DASP的泵站压力管道振动测试与分析

    Institute of Scientific and Technical Information of China (English)

    徐存东; 左罗; 张硕; 史国坤

    2013-01-01

    大型泵站的压力管道在运行中的振动问题比较普遍,高频大幅的管道振动会严重影响泵站提水系统的安全稳定运行,特殊的运行工况和管道内不稳定的水流流态是引起压力管道振动的主要原因,对压力管道的振动特性进行测试可以反演分析引起管道振动的机理并评价其运行的稳定性,文中采用DASP软件对大型泵站的压力管道振动特性进行测试,通过对代表性测点的信号采集和信号分析,可得到管道的原位振动特性图像.测试结果表明:将基于DASP的测试技术应用于泵站压力管道的振动测试,不仅能够获得管道振动的实时测试信号和振动特性图谱,还可获得振动机理分析所需的更高的测试精度和效率,在工程实践中具有较好的推广价值.%Vibration problem is relatively common with the pressure pipes in operation in large-scale pump stations. Pipeline vibration with high frequency and large amplitude will seriously affect safe and stable operation of water lift system in pump stations. Special conditions and pipeline unstable flow pattern are the main reason of pressure pipes vibration. By means of testing the vibration characteristics of pressure pipes and inversion analysis, the mechanism of pipeline vibration can be obtained and the stability of operation will be evaluated. In this paper, by using software DASP, the test of pressure pipe vibration characteristics in large pump stations was conducted. By means of signal acquisition and signal analysis on representative measuring point, an in-situ vibration characteristic image of the pipeline could be obtained. Testing result showed that the application of DASP-based testing technique to vibration test of pump station pressure pipes not only could obtain real-time test signal and vibration characteristic spectrum of pipeline vibration but would also obtain higher testing accuracy and efficiency indispensable to vibration mechanism analysis

  11. The risk of leukaemia in young children from exposure to tritium and carbon-14 in the discharges of German nuclear power stations and in the fallout from atmospheric nuclear weapons testing.

    Science.gov (United States)

    Wakeford, Richard

    2014-05-01

    Towards the end of 2007, the results were published from a case-control study (the "KiKK Study") of cancer in young children, diagnosed nuclear power stations in western Germany. The study found a tendency for cases of leukaemia to live closer to the nearest nuclear power station than their matched controls, producing an odds ratio that was raised to a statistically significant extent for residence within 5 km of a nuclear power station. The findings of the study received much publicity, but a detailed radiological risk assessment demonstrated that the radiation doses received by young children from discharges of radioactive material from the nuclear reactors were much lower than those received from natural background radiation and far too small to be responsible for the statistical association reported in the KiKK Study. This has led to speculation that conventional radiological risk assessments have grossly underestimated the risk of leukaemia in young children posed by exposure to man-made radionuclides, and particular attention has been drawn to the possible role of tritium and carbon-14 discharges in this supposedly severe underestimation of risk. Both (3)H and (14)C are generated naturally in the upper atmosphere, and substantial increases in these radionuclides in the environment occurred as a result of their production by atmospheric testing of nuclear weapons during the late 1950s and early 1960s. If the leukaemogenic effect of these radionuclides has been seriously underestimated to the degree necessary to explain the KiKK Study findings, then a pronounced increase in the worldwide incidence of leukaemia among young children should have followed the notably elevated exposure to (3)H and (14)C from nuclear weapons testing fallout. To investigate this hypothesis, the time series of incidence rates of leukaemia among young children risk of leukaemia in young children following the peak of above-ground nuclear weapons testing, or that incidence rates are

  12. Test Research on Exhaust Noise for Gasoline Engine Combusting Methanol-Gasoline Flexible Fuel%汽油机燃用甲醇-汽油灵活燃料的排气噪声试验研究

    Institute of Scientific and Technical Information of China (English)

    黄华; 崔国旭; 施兵峰; 陈振斌

    2016-01-01

    Under the condition that electronic control gasoline engine parameters aren't made any adjustment, and calibration based on pure gasoline fuel control strategy, the test combusting methanol-gasoline flexible fuel is carried out. It researches the influence on the exhaust noise characteristics by combusting flexible fuel (M15 and M85) through an engine. The test result under wide throttle open shows that in middle and high speed, exhaust noise of using methanol-gasoline fuel is higher than gasoline (M0), and the higher the methanol proportion, the heavier the exhaust noise is. At low speed, the condition is opposite. Through the curve of cylinder pressure and exhaust speed, it illustrates the reason of noise change. At last it researches noise change through simulating car driving on road at test bench, and the result shows that the noise decreases overall.%在电控汽油机参数未作任何调整的情况下,采用基于纯汽油标定的燃油控制策略,研究了某款车用汽油机燃用甲醇-汽油灵活燃料(M15和M85)对排气噪声特性的影响.结果表明:节气门全开时燃用甲醇-汽油混合燃料,在中、高转速时,排气噪声高于纯汽油(M0),且甲醇比例越高,排气噪声越大;在低转速时,则相反.同时,通过缸压曲线和排气流速,分析了噪声变化的原因.最后在台架上模拟整车在道路上运行时的噪声变化情况,总体上噪声下降.

  13. Secure base stations

    NARCIS (Netherlands)

    Bosch, Peter; Brusilovsky, Alec; McLellan, Rae; Mullender, Sape; Polakos, Paul

    2009-01-01

    With the introduction of the third generation (3G) Universal Mobile Telecommunications System (UMTS) base station router (BSR) and fourth generation (4G) base stations, such as the 3rd Generation Partnership Project (3GPP) Long Term Evolution (LTE) Evolved Node B (eNB), it has become important to se

  14. SPS rectifier stations

    CERN Multimedia

    CERN PhotoLab

    1974-01-01

    The first of the twelves SPS rectifier stations for the bending magnets arrived at CERN at the end of the year. The photograph shows a station with the rectifiers on the left and in the other three cubicles the chokes, capacitors and resistor of the passive filter.

  15. "Inventive" Learning Stations

    Science.gov (United States)

    Jarrett, Olga

    2010-01-01

    Learning stations can be used for myriad purposes--to teach concepts, integrate subject matter, build interest, and allow for inquiry--the possibilities are limited only by the imagination of the teacher and the supplies available. In this article, the author shares suggestions and a checklist for setting up successful learning stations. In…

  16. "Inventive" Learning Stations

    Science.gov (United States)

    Jarrett, Olga

    2010-01-01

    Learning stations can be used for myriad purposes--to teach concepts, integrate subject matter, build interest, and allow for inquiry--the possibilities are limited only by the imagination of the teacher and the supplies available. In this article, the author shares suggestions and a checklist for setting up successful learning stations. In…

  17. Meyrin Petrol Station

    CERN Multimedia

    2006-01-01

    Please note that the Meyrin petrol station will be closed for maintenance work on Tuesday 19 and Wednesday 20 December 2006. If you require petrol during this period we invite you to use the Prévessin petrol station, which will remain open. TS-IC-LO Section Tel.: 77039 - 73793

  18. High-Temperature Probe Station Developed to Characterize Microwave Devices Through 500 C

    Science.gov (United States)

    Downey, Alan N.; Schwartz, Zachary D.

    2004-01-01

    stations have been developed to test devices under other extreme environments, such as cryogenic temperatures as low as 37 K. Similarly, this custom probe station was specifically modified for high-temperature use. It allows devices to be measured quickly and flexibly, without the use of wire bonds and test fixtures. The probe station is shown making scattering parameter measurements from 1 to 50 GHz with a Hewlett-Packard 8510C Network Analyzer. There is a half-wafer of silicon directly on top of the heater to provide a uniform heated platform for our sample. A quarter wafer of silicon carbide forms the substrate for our test circuit of several transmission lines.

  19. Prefabricated modular district heating station is available rapidly. Welded transfer station DSP Midi; Vorgefertigte, modulare Fernwaermestation ist schnell verfuegbar. Geschweisste Uebergabestation DSP Midi

    Energy Technology Data Exchange (ETDEWEB)

    Simon, Joern [Danfoss GmbH, Hamburg (Germany). District Energy Div.

    2012-03-15

    Danfoss GmbH (Hamburg, Federal Republic of Germany) has developed a modular, standardized approach for welded district heating stations. The prefabricated transfer stations with a capacity up to 250 kW can be supplied in a compact frame. These stations have short delivery times and are extremely flexible: DSP MIDI systems have a modular design and adapters. Thus, DSP MIDI systems cover about 90 % of the technical connection requirements in Germany.

  20. Allowable Residual Contamination Levels in soil for decommissioning the Shippingport Atomic Power Station site

    Energy Technology Data Exchange (ETDEWEB)

    Kennedy, W.E. Jr.; Napier, B.A.; Soldat, J.K.

    1983-09-01

    As part of decommissioning the Shippingport Atomic Power Station, a fundamental concern is the determination of Allowable Residual Contamination Levels (ARCL) for radionuclides in the soil at the site. The ARCL method described in this report is based on a scenario/exposure-pathway analysis and compliance with an annual dose limit for unrestricted use of the land after decommissioning. In addition to naturally occurring radionuclides and fallout from weapons testing, soil contamination could potentially come from five other sources. These include operation of the Shippingport Station as a pressurized water reactor, operations of the Shippingport Station as a light-water breeder, operation of the nearby Beaver Valley reactors, releases during decommissioning, and operation of other nearby industries, including the Bruce-Mansfield coal-fired power plants. ARCL values are presented for 29 individual radionculides and a worksheet is provided so that ARCL values can be determined for any mixture of the individual radionuclides for any annual dose limit selected. In addition, a worksheet is provided for calculating present time soil concentration value that will decay to the ARCL values after any selected period of time, such as would occur during a period of restricted access. The ARCL results are presented for both unconfined (surface) and confined (subsurface) soil contamination. The ARCL method and results described in this report provide a flexible means of determining unrestricted-use site release conditions after decommissioning the Shippingport Atomic Power Station.

  1. The Roman stational liturgy

    Directory of Open Access Journals (Sweden)

    Janusz Mieczkowski

    2012-03-01

    Full Text Available The papal stational liturgy in Rome was a particular kind of worship service from the Christian Antiquity to the XIV century. Its essential elements are four. Its always took place under the leadership of the pope or his representative. This form of liturgy was mobile: it was celebrated in different basilicas or churches of Rome. Third, the choice of church depended on the feast, liturgical seasons or commemoration being celebrated. Fourth, the stational liturgy was the urban liturgical celebration of the day. The highpoint of this system was Lent. Throughout the entire system Church of Rome manifested its own unity. The station was usually the Pope’s solemn mass in the stational church for the whole city. But on certain days in the year the Pope went in another church (collecta, from which a solemn procession was made to the stational church.

  2. Central Station Design Options

    DEFF Research Database (Denmark)

    2011-01-01

    The purpose of EDISON Work Package 4.1 is the evaluation of possible Central (charging) Stations design options for making possible the public charging of Electric Vehicles (EVs). A number of scenarios for EVs are assessed, with special emphasis on the options of Fast Charging and Battery Swapping....... The work identifies the architecture, sizing and siting of prospective Central Stations in Denmark, which can be located at shopping centers, large car parking lots or gas stations. Central Stations are planned to be integrated in the Danish distribution grid. The Danish island of Bornholm, where a high.......g. due to vandalism, the charge supply circuit is disconnected. More electrical vehicles on the market are capable today of quick charging up to 50 kW power level. The feasibility of Central Stations with fast charging/swapping option, their capacity, design, costs and grid impact, as well as battery...

  3. ANFIS Modelling of Flexible Plate Structure

    Directory of Open Access Journals (Sweden)

    A. A. M. Al-Khafaji

    2010-06-01

    Full Text Available This paper presented an investigation into the performance of system identification using an Adaptive Neuro-Fuzzy Inference System (ANFIS technique for the dynamic modelling of a twodimensional flexible plate structure. It is confirmed experimentally, using National Instrumentation (NI Data Acquisition System (DAQ and flexible plate test rig that ANFIS can be effectively used for modelling the system with highly accurate results. The accuracy of the modelling results is demonstrated through validation tests including training and test validation and correlation tests.

  4. Regeneration of water at space stations

    Science.gov (United States)

    Grigoriev, A. I.; Sinyak, Yu. E.; Samsonov, N. M.; Bobe, L. S.; Protasov, N. N.; Andreychuk, P. O.

    2011-05-01

    The history, current status and future prospects of water recovery at space stations are discussed. Due to energy, space and mass limitations physical/chemical processes have been used and will be used in water recovery systems of space stations in the near future. Based on the experience in operation of Russian space stations Salut, Mir and International space station (ISS) the systems for water recovery from humidity condensate and urine are described. A perspective physical/chemical system for water supply will be composed of an integrated system for water recovery from humidity condensate, green house condensate, water from carbon dioxide reduction system and condensate from urine system; a system for water reclamation from urine; hygiene water processing system and a water storage system. Innovative processes and new water recovery systems intended for Lunar and Mars missions have to be tested on the international space station.

  5. Functional Specification of the test project Operational Management Centre/Power Substation Communication communication. Functionele Specificatie van het proefproject BVC-station communicatie

    Energy Technology Data Exchange (ETDEWEB)

    Spelt, H.G. (KEMA Procesautomatisering en Informatietechnologie, Arnhem (Netherlands))

    1993-01-01

    The aim of the title project is to evaluate the computer program ELCOM90 and to determine its suitability for the communication and data exchange between an operational management center and a power substation. A document has been drafted which will serve as a reference document in the design-, construction- and implementation phases of the ELCOM90 test project. In the document the system functions are described as well as the demands that have to be fulfilled. The functional specification phase is finished. The design- and realization phase is started. Mid-1993 the test project will be completed and demonstrations will be given

  6. 压水堆核电站核三级屏蔽电泵试验鉴定程序%Testing of Nuclear Three-stage Shielded Electric Pump for Pressurized Water Reactor Nuclear Power Station

    Institute of Scientific and Technical Information of China (English)

    李作维; 孙悦; 薄大威

    2015-01-01

    This paper analyzes the necessity of obtaining the design/manufacture license of three generation nuclear power plants with two generation of pressurized water reactor nuclear power plant. Describe the function and structure of the three stage pump. Especially introduce the program and test method of the two generation of nuclear power station in three gener-ation pressurized water reactor nuclear power station.%分析了二代加压水堆核电站核三级屏蔽电泵取得民用核安全设备 (屏蔽泵) 设计/制造许可证的必要性, 对核三级屏蔽电泵的功能、 规格及结构进行了详细的阐述, 并重点针对二代加压水堆核电站核三级屏蔽电泵试验鉴定的程序及试验方法进行了介绍, 为核三级屏蔽电泵鉴定提供了依据.

  7. Research on Test and Diagnosis System on AVR of the Rocket Cannon Supplemental Power Station%某型火箭炮配套电站AVR测试诊断系统研究

    Institute of Scientific and Technical Information of China (English)

    高伟波; 刘洪文; 谷志锋

    2011-01-01

    According to the key and urgency of test and diagnosis system on AVR of the rocket cannon supplemental power station, this paper was used to design the test and diagnosis system. Firstly, this paper analyzed the importance in power station and the necessariness in fault diagnosis, and educed the importance of design about AVR diagnosis system. Secondly, this paper analyzed working principle and the structural composition of AVR, and reviewed the evolution history of test technology and fault diagnosis technology, especially go with the vigorous development of virtual instrument technology and the reasonable application of fault tree. Finally, this paper educed the design block diagram including the hardware, software as well as fault analysis method.%针对某型火箭炮配套电站AVR测试诊断的关键性和迫切性,该文用于研究设计AVR诊断测试系统.首先通过分析AVR在电站中重要性和故障诊断的必要性,得出AVR诊断系统设计的重要性,其次分析了该AVR的结构组成及其工作原理,并回顾了测试技术和故障诊断技术的沿革史,特别是虚拟仪器技术的蓬勃发展和故障树的合理应用性,最后得出系统设计框图、该系统设计的硬件、软件以及故障分析方法.

  8. 低频导波在场站管道检测中的应用研究%Apply low-frequency ultrasonic guided wave testing system to inspect pipelines in gas station

    Institute of Scientific and Technical Information of China (English)

    宋日生; 喻建胜; 何莎; 王文韬; 彭星煜

    2012-01-01

    There is no effective means for wholly comprehensive inspection of pipelines in the gas station because of the complex laying environment. In response to this situation, the UK GUL's WaveMaker G3 low-frequency ultrasonic guided wave testing system was introduced. In order to check the performances of this system, such as detection sensitivity, defects positioning accuracy, detection range and type of defect, and so on, the experiment of inspecting pipelines was carried in the gas station of PetroChina Southwest Oil & Gas Field Company. The test results showed that WaveMaker G3 low -frequency ultrasonic guided wave testing system can be used for inspecting the location of corrosion and the decrease of wall thickness. It also can position the defects precisely through identifying the typical characteristics signal, e.g., welds etc. Thus, the corrosion of the whole pipeline can be inspected. It will provide a strong technical support for detecting and evaluating the station pipelines, gathering & transportation pipelines and long-distance pipelines in oil and gas fields.%针对输气场站内管道敷设环境复杂,一直没有有效的手段进行100%的全面检测这一状况,引进英国GUL公司的WaveMaker G3低频导波检测系统对中国石油西南油气田公司的某场站输气管道进行了检测试验,来验证系统检测灵敏度、缺陷定位准确度、检测距离和检测缺陷类型等性能指标.试验表明:WaveMaker G3低频导波检测系统可以检出管道局部腐蚀以及壁厚减薄情况,并通过对典型的特征信号如焊缝等的识别可以实现对缺陷准确定位,从而掌握管道的整体腐蚀状况,为各大油气田的场站管道、集输管道以及长输管道的维护决策提供技术支持.

  9. Protection testing of a modernised medium-voltage switching station in accordance with IEC 61850. An experience report; Schutzpruefung einer erneuerten Mittelspannungsschaltanlage mit IEC 61850. Ein Erfahrungsbericht

    Energy Technology Data Exchange (ETDEWEB)

    Kroll, Karlheinz [MVV Energie AG, Netzschutz- und Stationsleittechnik, Mannheim (Germany); Schossig, Thomas [Omicron electronics GmbH, Product Management, Klaus (Austria)

    2009-08-15

    At MW Energie AG the protection of an installation was entirely renewed. Protection messages to the control system are transmitted in accordance with IEC 61850. Since not all testing signals are available in conventional wiring, the configuration has been extended to permit fast real-time communication with Goose.

  10. Results from tests of the system for automatically controlling frequency and power of the PGU-450 power unit at the kaliningrad TETs-2 cogeneration station

    Science.gov (United States)

    Bilenko, V. A.; Manevskaya, O. A.; Melamed, A. D.

    2008-10-01

    The structure of the system and the results of tests for checking the preparedness of the power unit for common primary control of the network frequency are described. An analysis of the results is presented, and an assessment is made of whether the PGU-450 unit can participate in selective primary and automatic secondary control of frequency and power.

  11. Compression and immersion tests and leaching of radionuclides, stable metals, and chelating agents from cement-solidified decontamination waste collected from nuclear power stations

    Energy Technology Data Exchange (ETDEWEB)

    Akers, D.W.; Kraft, N.C.; Mandler, J.W. [EG and G Idaho, Inc., Idaho Falls, ID (United States)

    1994-06-01

    A study was performed for the Nuclear Regulatory Commission (NRC) to evaluate structural stability and leachability of radionuclides, stable metals, and chelating agents from cement-solidified decontamination ion-exchange resin wastes collected from seven commercial boiling water reactors and one pressurized water reactor. The decontamination methods used at the reactors were the Can-Decon, AP/Citrox, Dow NS-1, and LOMI processes. Samples of untreated resin waste and solidified waste forms were subjected to immersion and compressive strength testing. Some waste-form samples were leach-tested using simulated groundwaters and simulated seawater for comparison with the deionized water tests that are normally performed to assess waste-form leachability. This report presents the results of these tests and assesses the effects of the various decontamination methods, waste form formulations, leachant chemical compositions, and pH of the leachant on the structural stability and leachability of the waste forms. Results indicate that releases from intact and degraded waste forms are similar and that the behavior of some radionuclides such as {sup 55}Fe, {sup 60}Co, and {sup 99}Tc were similar. In addition, the leachability indexes are greater than 6.0, which meets the requirement in the NRC`s ``Technical Position on Waste Form,`` Revision 1.

  12. Analysis and test of power consumption in paddy threshing using flexible and rigid teeth%柔性齿与刚性齿脱粒水稻功耗比较分析与试验

    Institute of Scientific and Technical Information of China (English)

    任述光; 谢方平; 罗锡文; 孙松林

    2013-01-01

    The study and use of flexible threshing teeth are of interest to researchers in agricultural mechanization because flexible teeth appear to damage grain less than rigid teeth. For a flexible threshing tooth, consisting of an elastic beam fixed on one end, a differential equation of its deformation curve was created, the deformation of which was calculated by numerical methods, which provided necessary condition for dynamic analysis. The corresponding formulation of calculating power consumption was deduced based on theoretic analysis in this paper. The hypothesis was as follows:the threshing roller was regarded as rigid body, the threshing teeth as elastic bodies, and threshing as the impact between threshing teeth and paddy rice. The differences in impulse moment and beating force for paddy grain between the rigid threshing tooth and the flexible one were analyzed and compared, and their respective power-consumption models were established in this paper. By analyzing the loss of kinetic energy and impact momentum for the threshing processing using the rigid threshing tooth and the flexible one, we concluded that the loss of kinetic energy of flexible threshing was less than that of rigid threshing;likewise, power consumption by flexible-tooth threshing is less than that by rigid-tooth threshing if the feed rates and the rotary speed are equal. Meanwhile, the theoretical analysis results show that the beating force of the flexible tooth was less than that of the rigid tooth, which was confirmed experimentally. Experimental data showed that the threshing roller has to have a sufficiently high moment of inertia, and the engine enough power, to preserve the stability of the threshing process. We fabricated a number of experimental devices including a transducer for measuring torque, an apparatus to measure angular velocity, and a feeding test-bed. Experiments were conducted by measuring torsion and angular velocity, enabling us to compute the brake power of flexible

  13. Behavioral flexibility and problem solving in an invasive bird.

    Science.gov (United States)

    Logan, Corina J

    2016-01-01

    Behavioral flexibility is considered an important trait for adapting to environmental change, but it is unclear what it is, how it works, and whether it is a problem solving ability. I investigated behavioral flexibility and problem solving experimentally in great-tailed grackles, an invasive bird species and thus a likely candidate for possessing behavioral flexibility. Grackles demonstrated behavioral flexibility in two contexts, the Aesop's Fable paradigm and a color association test. Contrary to predictions, behavioral flexibility did not correlate across contexts. Four out of 6 grackles exhibited efficient problem solving abilities, but problem solving efficiency did not appear to be directly linked with behavioral flexibility. Problem solving speed also did not significantly correlate with reversal learning scores, indicating that faster learners were not the most flexible. These results reveal how little we know about behavioral flexibility, and provide an immense opportunity for future research to explore how individuals and species can use behavior to react to changing environments.

  14. Painful Flexible Flatfoot.

    Science.gov (United States)

    Sheikh Taha, Abdel Majid; Feldman, David S

    2015-12-01

    Flatfoot is commonly encountered by pediatric orthopedic surgeons and pediatricians. A paucity of literature exists on how to define a flatfoot. The absence of the medial arch with a valgus hindfoot is the hallmark of this pathology. Flatfoot can be flexible or rigid. This review focuses on the diagnosis and treatment of the flexible flatfoot. Most flatfeet are flexible and clinically asymptomatic, and warrant little intervention. If feet are symptomatic, treatment is needed. Most patients who require treatment improve with foot orthotics and exercises. Only feet resistant to conservative modalities are deemed surgical candidates. The presence of a tight heel cord is often found in patients who fail conservative management.

  15. Flexible Support Stanchion

    Energy Technology Data Exchange (ETDEWEB)

    Rudland, D.L.; /Fermilab

    1987-05-11

    Figure 1 shows the assembly drawing of the Central Calorimeter Cryostat Flexible Support Stanchion. Figures 2 and 3 show the Flexible Support STanchion in detail. These Stanchions support the cryostat safely, reduce the heat load to the cryostat from the ambient by a factor of more than ten, provide a spring like action that reduce the loads created by thermal contraction of the cryostat and position the cryostate accurately. Table 1 shows all of the details of the Flexible Support system for the C.C. Cryostat.

  16. Brief report: cognitive flexibility and focused attention in children and adolescents with Asperger syndrome or high-functioning autism as measured on the computerized version of the Wisconsin Card Sorting Test.

    Science.gov (United States)

    Kaland, Nils; Smith, Lars; Mortensen, Erik Lykke

    2008-07-01

    The aim of the present study was to assess mental flexibility and set maintenance of a group of individuals with Asperger syndrome (AS) or high-functioning autism (HFA) (N = 13; mean age 16,4), as compared with a matched group of typically developing children and adolescents (N = 13; mean age 15,6) on the computerized version of the Wisconsin Card Sorting Test (WCST). The participants in the AS/HFA group performed less well than the controls on all categories of the WCST, but the differences did not reach conventional statistical significance on most categories of the WCST. On the category failure to maintain set, however, the AS/HFA participants performed significantly less well than the controls, suggesting a deficit of focused attention.

  17. Development and evaluation of test stations for the quality assurance of the silicon micro-strip detector modules for the CMS experiment

    Energy Technology Data Exchange (ETDEWEB)

    Poettgens, M.

    2007-11-22

    CMS (Compact Muon Solenoid) is one of four large-scale detectors which will be operated at the LHC (Large Hadron Collider) at the European Laboratory for Particle Physics (CERN). For the search for new physics the reconstruction of the collision products and their properties is essential. In the innermost part of the CMS detector the traces of ionizing particles are measured utilizing a silicon tracker. A large fraction of this detector is equipped with silicon micro-strip modules which provide a precise space resolution in 1-dimension. A module consists of a sensor for detection of particles, the corresponding read-out electronics (hybrid) and a mechanical support structure. Since the 15,148 modules, which will be installed in the silicon micro-strip detector, have a total sensitive surface area of about 198 m{sup 2}, the inner tracker of CMS is the largest silicon tracking detector, which has ever been built. While the sensors and hybrids are produced in industry, the construction of the modules and the control of the quality is done by the members of the 21 participating institutes. Since the access to the silicon micro-strip tracker will be very limited after the installation in the CMS detector the installed modules must be of high quality. For this reason the modules are thoroughly tested and the test results are uploaded to a central database. By the development of a read-out system and the corresponding software the III. Physikalisches Institut made an important contribution for the electrical and functional quality control of hybrids and modules. The read-out system provides all features for the operation and test of hybrids and modules and stands out due to high reliability and simple handling. Because a very user-friedly and highly automated software it became the official test tool and was integrated in various test stands. The test stands, in which the read-out system is integrated in, are described and the tests which are implemented in the

  18. Finite element analysis of flexible, rotating blades

    Science.gov (United States)

    Mcgee, Oliver G.

    1987-01-01

    A reference guide that can be used when using the finite element method to approximate the static and dynamic behavior of flexible, rotating blades is given. Important parameters such as twist, sweep, camber, co-planar shell elements, centrifugal loads, and inertia properties are studied. Comparisons are made between NASTRAN elements through published benchmark tests. The main purpose is to summarize blade modeling strategies and to document capabilities and limitations (for flexible, rotating blades) of various NASTRAN elements.

  19. Ageing characterization of exhaust flexible couplings

    OpenAIRE

    2012-01-01

    The aim of this work is to investigate the mechanical strength of automotive exhaust flexible couplings subjected to thermo-mechanical fatigue and corrosion. Five different types of flexible coupling have been considered, realised by four different king of materials: three stainless steels (AISI 309, AISI 321, AISI 321 Ti) and a nickel alloy (Incoloy 825). These components have been tested by a dedicated procedure consisting of different cycles of fatigue, heating and corrosion. Performances ...

  20. No effects of power line frequency extremely low frequency electromagnetic field exposure on selected neurobehavior tests of workers inspecting transformers and distribution line stations versus controls.

    Science.gov (United States)

    Li, Li; Xiong, De-fu; Liu, Jia-wen; Li, Zi-xin; Zeng, Guang-cheng; Li, Hua-liang

    2014-03-01

    We aimed to evaluate the interference of 50 Hz extremely low frequency electromagnetic field (ELF-EMF) occupational exposure on the neurobehavior tests of workers performing tour-inspection close to transformers and distribution power lines. Occupational short-term "spot" measurements were carried out. 310 inspection workers and 300 logistics staff were selected as exposure and control. The neurobehavior tests were performed through computer-based neurobehavior evaluation system, including mental arithmetic, curve coincide, simple visual reaction time, visual retention, auditory digit span and pursuit aiming. In 500 kV areas electric field intensity at 71.98% of total measured 590 spots were above 5 kV/m (national occupational standard), while in 220 kV areas electric field intensity at 15.69% of total 701 spots were above 5 kV/m. Magnetic field flux density at all the spots was below 1,000 μT (ICNIRP occupational standard). The neurobehavior score changes showed no statistical significance. Results of neurobehavior tests among different age, seniority groups showed no significant changes. Neurobehavior changes caused by daily repeated ELF-EMF exposure were not observed in the current study.

  1. User Context Aware Base Station Power Flow Model

    OpenAIRE

    Walsh, Barbara; Farrell, Ronan

    2005-01-01

    At present the testing of power amplifiers within base station transmitters is limited to testing at component level as opposed to testing at the system level. While the detection of catastrophic failure is possible, that of performance degradation is not. This paper proposes a base station model with respect to transmitter output power with the aim of introducing system level monitoring of the power amplifier behaviour within the base station. Our model reflects the expe...

  2. Space station operations management

    Science.gov (United States)

    Cannon, Kathleen V.

    1989-01-01

    Space Station Freedom operations management concepts must be responsive to the unique challenges presented by the permanently manned international laboratory. Space Station Freedom will be assembled over a three year period where the operational environment will change as significant capability plateaus are reached. First Element Launch, Man-Tended Capability, and Permanent Manned Capability, represent milestones in operational capability that is increasing toward mature operations capability. Operations management concepts are being developed to accomodate the varying operational capabilities during assembly, as well as the mature operational environment. This paper describes operations management concepts designed to accomodate the uniqueness of Space Station Freedoom, utilizing tools and processes that seek to control operations costs.

  3. For largest space flexibility and largest energy efficiency. Modern room automation enables an open-space solution in the arched structures of the central railway station; Fuer groesste Raumflexibilitaet und hoechste Energieeffizienz. Moderne Raumautomation ermoeglicht Open-Space Loesung in den Buegelbauten des Berliner Hauptbahnhofs

    Energy Technology Data Exchange (ETDEWEB)

    Ottilinger, Werner [Sauter Deutschland, Freiburg im Breisgau (Germany)

    2013-05-15

    A feature of the central railway station in Berlin are the 46 meters high arched structures that span the railway station and accommodate more than 1,500 employees of the Deutsche Bahn AG (Berlin, Federal Republic of Germany). A total of 42,000 square meters of office space and a large business and conference center spread on twelve floors. Within the commissioning of this central railway station, this vast area should be designed technically variable in order to hold the time and cost as low as possible for the reconstruction or change of tenants.

  4. Flexible Word Classes

    DEFF Research Database (Denmark)

    2013-01-01

    • First major publication on the phenomenon • Offers cross-linguistic, descriptive, and diverse theoretical approaches • Includes analysis of data from different language families and from lesser studied languages This book is the first major cross-linguistic study of 'flexible words', i.e. words...... that cannot be classified in terms of the traditional lexical categories Verb, Noun, Adjective or Adverb. Flexible words can - without special morphosyntactic marking - serve in functions for which other languages must employ members of two or more of the four traditional, 'specialised' word classes. Thus......, flexible words are underspecified for communicative functions like 'predicating' (verbal function), 'referring' (nominal function) or 'modifying' (a function typically associated with adjectives and e.g. manner adverbs). Even though linguists have been aware of flexible world classes for more than...

  5. Flexible displays, rigid designs?

    DEFF Research Database (Denmark)

    Hornbæk, Kasper

    2015-01-01

    Rapid technological progress has enabled a wide range of flexible displays for computing devices, but the user experience--which we're only beginning to understand--will be the key driver for successful designs....

  6. Flexibility in insulin prescription

    Directory of Open Access Journals (Sweden)

    Sanjay Kalra

    2016-01-01

    Full Text Available This communication explores the concept of flexibility, a propos insulin preparations and insulin regimes used in the management of type 2 diabetes. The flexibility of an insulin regime or preparation is defined as their ability to be injected at variable times, with variable injection-meal time gaps, in a dose frequency and quantum determined by shared decision making, with a minimal requirement of glucose monitoring and health professional consultation, with no compromise on safety, efficiency and tolerability. The relative flexibility of various basal, prandial and dual action insulins, as well as intensive regimes, is compared. The biopsychosocial model of health is used to assess the utility of different insulins while encouraging a philosophy of flexible insulin usage.

  7. Space Station solar water heater

    Science.gov (United States)

    Horan, D. C.; Somers, Richard E.; Haynes, R. D.

    1990-01-01

    The feasibility of directly converting solar energy for crew water heating on the Space Station Freedom (SSF) and other human-tended missions such as a geosynchronous space station, lunar base, or Mars spacecraft was investigated. Computer codes were developed to model the systems, and a proof-of-concept thermal vacuum test was conducted to evaluate system performance in an environment simulating the SSF. The results indicate that a solar water heater is feasible. It could provide up to 100 percent of the design heating load without a significant configuration change to the SSF or other missions. The solar heater system requires only 15 percent of the electricity that an all-electric system on the SSF would require. This allows a reduction in the solar array or a surplus of electricity for onboard experiments.

  8. Testing flight software on the ground: Introducing the hardware-in-the-loop simulation method to the Alpha Magnetic Spectrometer on the International Space Station

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Wenhao, E-mail: wenhao_sun@126.com [Southeast University, Nanjing 210096 (China); Cai, Xudong [Massachusetts Institute of Technology, MA 02139-4307 (United States); Meng, Qiao [Southeast University, Nanjing 210096 (China)

    2016-04-11

    Complex automatic protection functions are being added to the onboard software of the Alpha Magnetic Spectrometer. A hardware-in-the-loop simulation method has been introduced to overcome the difficulties of ground testing that are brought by hardware and environmental limitations. We invented a time-saving approach by reusing the flight data as the data source of the simulation system instead of mathematical models. This is easy to implement and it works efficiently. This paper presents the system framework, implementation details and some application examples.

  9. COUPLING EFFECT OF FLEXIBLE JOINT AND FLEXIBLE LINK ON DYNAMIC SINGULARITY OF FLEXIBLE MANIPULATOR

    Institute of Scientific and Technical Information of China (English)

    GAO Zhihui; YUN Chao; BIAN Yushu

    2008-01-01

    The coupling effect of the flexible joint and the flexible link on the dynamic singularity of the flexible manipulator is addressed. Firstly, the dynamic equations of a flexible manipulator with a flexible joint and a flexible link are derived. Secondly, the relationship and property between the flexible joint and the flexible link are analyzed. It shows that the flexible joint's amplitude will increase abruptly, thereby the dynamic singularity occurs if the frequency of a flexible joint is near or equal to some natural frequency of a flexible link. Finally, some numerical simulations which will verify the correctness of the theoretical analysis, are carried out. The results are fundamental for the design of a flexible manipulator and for the avoidance of the dynamic singularity.

  10. 拉萨地区不同空隙率的半柔性路面材料冻融试验研究%Freezing-Thawing Test Research of Semi-Flexible Pavement Materials with Different Void Fraction in Lhasa

    Institute of Scientific and Technical Information of China (English)

    李成洋; 张鹏; 王文奇; 田荣燕

    2016-01-01

    为解决现有水泥混凝土和沥青混凝土路面材料在拉萨地区推广应用中受冻融作用破坏的问题,对不同空隙率的半柔性路面材料在拉萨的应用进行研究。采用灌注式的方式将水泥胶浆灌入不同空隙率的开级配沥青混合料母体中制成试件,并根据拉萨独特的气候特征设定冻融试验的时间和温度;再进行高温稳定试验和低温抗裂试验,得出趋近于真实冻融环境的试验数据。分析试验数据可得,半柔性路面材料在受到冻融作用破坏时,低温抗裂强度随着空隙率的增大呈逐渐上升趋势,劈裂位移量随着空隙率的增大呈逐渐减小趋势;而表征高温稳定性能的动稳定度随着空隙率的增大呈先上升后下降的趋势,变形速率随着空隙率的增大呈先下降后上升的趋势。研究结果表明,半柔性路面材料采用27%的空隙率并添加塑弹性材料有利于抵抗冻融破坏,从而能够在高原地区推广和应用。%In order to solve the problem that the cement concrete and asphalt concrete pavement materi⁃al were damaged by freezing-thawing action during their popularization and application in Lhasa, a re⁃search about the application of semi-flexible pavement materials with different void fraction in Lhasa was carried out. Test specimens were made by the way of pouring cement mortar into open-graded as⁃phalt mixture matrix with different void fraction. The time and temperature of freezing-thawing test were set based on the special environment of Lhasa. Then the high-temperature stability test and low-temper⁃ature crack resistance test were carried out to obtain the test data closing to the real environment. By ana⁃lyzing the test data, it was educed that:when semi-flexible pavement material was destroyed by freezing-thawing action, with the increasing of void fraction, the low-temperature crack resistance increased grad⁃ually, and the split displacement

  11. The vibrational progressions of the N-->V electronic transition of ethylene: a test case for the computation of Franck-Condon factors of highly flexible photoexcited molecules.

    Science.gov (United States)

    Borrelli, Raffaele; Peluso, Andrea

    2006-11-21

    The vibrational progressions of the N-->V electronic transition of ethylene--a test case for the computation of Franck-Condon factors between electronic states exhibiting very different equilibrium geometries--have been calculated by using both the Cartesian and the curvilinear internal coordinate representations of the normal modes of vibration. The comparison of the theoretical spectra with the experimental one shows that the Cartesian representation yields vibrational progressions which are not observed in the experimental spectrum, whereas the curvilinear one gives a very satisfying agreement, even in harmonic approximation.

  12. Strategic planning for the International Space Station

    Science.gov (United States)

    Griner, Carolyn S.

    1990-01-01

    The concept for utilization and operations planning for the International Space Station Freedom was developed in a NASA Space Station Operations Task Force in 1986. Since that time the concept has been further refined to definitize the process and products required to integrate the needs of the international user community with the operational capabilities of the Station in its evolving configuration. The keystone to the process is the development of individual plans by the partners, with the parameters and formats common to the degree that electronic communications techniques can be effectively utilized, while maintaining the proper level and location of configuration control. The integration, evaluation, and verification of the integrated plan, called the Consolidated Operations and Utilization Plan (COUP), is being tested in a multilateral environment to prove out the parameters, interfaces, and process details necessary to produce the first COUP for Space Station in 1991. This paper will describe the concept, process, and the status of the multilateral test case.

  13. Flexible implementation of rigid solar cell technologies.

    Energy Technology Data Exchange (ETDEWEB)

    Hollowell, Andrew E.

    2010-08-01

    As a source of clean, remote energy, photovoltaic (PV) systems are an important area of research. The majority of solar cells are rigid materials with negligible flexibility. Flexible PV systems possess many advantages, such as being transportable and incorporable on diverse structures. Amorphous silicon and organic PV systems are flexible; however, they lack the efficiency and lifetime of rigid cells. There is also a need for PV systems that are light weight, especially in space and flight applications. We propose a solution to this problem by arranging rigid cells onto a flexible substrate creating efficient, light weight, and flexible devices. To date, we have created a working prototype of our design using the 1.1cm x 1cm Emcore cells. We have achieved a better power to weight ratio than commercially available PowerFilm{reg_sign}, which uses thin film silicon yielding .034W/gram. We have also tested our concept with other types of cells and verified that our methods are able to be adapted to any rigid solar cell technology. This allows us to use the highest efficiency devices despite their physical characteristics. Depending on the cell size we use, we can rival the curvature of most available flexible PV devices. We have shown how the benefits of rigid solar cells can be integrated into flexible applications, allowing performance that surpasses alternative technologies.

  14. Signal Station Inspection Reports

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Handwritten reports resulting from detailed inspections of US Army Signal Service Stations, 1871-1889. Features reported included instrument exposure and condition,...

  15. FEMA DFIRM Station Start

    Data.gov (United States)

    Minnesota Department of Natural Resources — This table contains information about station starting locations. These locations indicate the reference point that was used as the origin for distance measurements...

  16. "Central Station" Londonis

    Index Scriptorium Estoniae

    2000-01-01

    Londoni galeriis Milch seitsme läti, leedu ja eesti kunstniku projekt "Central Station". Kuraatorid Lisa Panting, Sally Tallant. Eestist osalevad Hanno Soans (Catarina Campinoga koostöös valminud video), Kiwa, Kai Kaljo

  17. Realtime USGS Streamflow Stations

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — Approximately 5,000 of the 6,900 U.S. Geological Survey sampling stations are equipped with telemetry to transmit data on streamflow, temperature, and other...

  18. "Central Station" Londonis

    Index Scriptorium Estoniae

    2000-01-01

    Londoni galeriis Milch seitsme läti, leedu ja eesti kunstniku projekt "Central Station". Kuraatorid Lisa Panting, Sally Tallant. Eestist osalevad Hanno Soans (Catarina Campinoga koostöös valminud video), Kiwa, Kai Kaljo

  19. ASOS Station Photos

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The images contained in this library are of stations in the Automated Surface Observing System (ASOS) network. These images were taken between 1998-2001 for the ASOS...

  20. Master Station History Report

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Standard/Legacy MSHR, formally identified as the DSI-9767 dataset, is the legacy dataset/report sorted by NCDC Station ID and period of record. This...

  1. Natural Weathering Exposure Station

    Data.gov (United States)

    Federal Laboratory Consortium — The Corps of Engineers' Treat Island Natural Weathering Exposure Station is a long-term natural weathering facility used to study concrete durability. Located on the...

  2. Station Management Plan

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — The following plan is the result of a recent initiative in Region 5 to produce general management guidance based on stated objectives for individual field stations....

  3. Maine Field Station

    Data.gov (United States)

    Federal Laboratory Consortium — In 2000 NOAA's National Marine Fisheries Service established the Maine Field Station in Orono, ME to have more direct involvement in the conservation of the living...

  4. Electrostatic pickup station

    CERN Multimedia

    CERN PhotoLab

    1982-01-01

    Electrostatic pickup station, with 4 interleaved electrodes, to measure beam position in the horizontal and vertical plane. This type is used in the transfer lines leaving the PS (TT2, TT70, TTL2). See also 7904075.

  5. USRCRN Station Information

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Documentation of United States Regional Climate Reference Network (USRCRN) installations in 2009. Installations documented are for USRCRN pilot project stations in...

  6. Mukilteo Research Station

    Data.gov (United States)

    Federal Laboratory Consortium — Research at the Mukilteo Research Station focuses on understanding the life cycle of marine species and the impacts of ecosystem stressors on anadromous and marine...

  7. TV Analog Station Transmitters

    Data.gov (United States)

    Department of Homeland Security — This file is an extract from the Consolidated Database System (CDBS) licensed by the Media Bureau. It consists of Analog Television Stations (see Rule Part47 CFR...

  8. Public Transit Stations

    Data.gov (United States)

    Department of Homeland Security — fixed rail transit stations within the Continental United States, Alaska, Hawaii, the District of Columbia, and Puerto Rico. The modes of transit that are serviced...

  9. Routes and Stations

    Data.gov (United States)

    Department of Homeland Security — he Routes_Stations table is composed of fixed rail transit systems within the Continental United States, Alaska, Hawaii, the District of Columbia, and Puerto Rico....

  10. Active Marine Station Metadata

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Active Marine Station Metadata is a daily metadata report for active marine bouy and C-MAN (Coastal Marine Automated Network) platforms from the National Data...

  11. Enhanced Master Station History Report

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Enhanced Master Station History Report (EMSHR) is a compiled list of basic, historical information for every station in the station history database, beginning...

  12. The influence of strength, flexibility, and simultaneous training on flexibility and strength gains.

    Science.gov (United States)

    Simão, Roberto; Lemos, Adriana; Salles, Belmiro; Leite, Thalita; Oliveira, Élida; Rhea, Matthew; Reis, Victor Machado

    2011-05-01

    The purpose of this study was to examine the strength and flexibility gains after isolated or simultaneous strength and flexibility training after 16 weeks. Eighty sedentary women were randomly assigned to 1 of 4 groups: strength training (ST; n = 20), flexibility training (FLEX) (n = 20), combination of both (ST + FLEX; n = 20) and control group (CG; n = 20). All the groups performed pre and posttraining sit and reach test to verify the flexibility level and 10RM test for leg press and bench press exercises. The training protocol for all groups, except for the CG, included 3 weekly sessions, in alternated days, totaling 48 sessions. Strength training was composed of 8 exercises for upper and lower body, executed in 3 sets of periodized training. The flexibility training was composed of static stretching exercises that involved upper and lower body. Results showed that ST (30 ± 2.0 to 36 ± 3.0 cm), ST + FLEX (31 ± 1.0 to 42 ± 4.0 cm), and FLEX (32 ± 3.0 to 43 ± 2.0 cm) significantly increased in flexibility in relation to baseline and to CG (30 ± 2.0 to 30 ± 2.0 cm); however, no significant differences were observed between the treatment conditions. Strength tests demonstrated that ST and ST + FLEX significantly increased 10RM when compared to baseline, FLEX, and the CG. In conclusion, short-term strength training increases flexibility and strength in sedentary adult women. Strength training may contribute to the development and maintenance of flexibility even without the inclusion of additional stretching, but strength and flexibility can be prescribed together to get optimal improvements in flexibility.

  13. Leadership at Antarctic Stations.

    Science.gov (United States)

    1987-03-01

    Claseification 6. No. Pegees LEADERSHIP AT ANTARTIC STATIONS hxIs i4 5, C =r~eta(C), 17 Rfs~W (R, Udusiied U)J 7. No Refs 8. Author(s) Edocumesnt I...whether there is a "best" approach to leadership at an Antartic Station and what leadership style may have the most to offer. 3~~ __ ___ Tipesis to be

  14. LAERTIS, a multidisciplinary station

    Science.gov (United States)

    Aggouras, G.; Anassontzis, E. G.; Ball, A. E.; Chinowsky, W.; Fahrun, E.; Grammatikakis, G.; Green, C.; Grieder, P.; Katrivanos, P.; Koske, P.; Markopoulos, E.; Minkowsky, P.; Nygren, D.; Papageorgiou, K.; Przybylski, G.; Resvanis, L. K.; Siotis, I.; Sopher, J.; Tsagli, V.; Zhukov, V. A.

    2006-11-01

    LAERTIS, designed to collect environmental data from the deep-sea, is operated since 1999 and has been deployed several time at 4000 m depth at the NESTOR site. Power and data were transferred through a 30-km electro-optical cable to the Shore Station. In this report, we describe briefly the LAERTIS instrumentation and present typical data that were collected successfully during those deployment demonstrating the importance of a deep-sea station permanently connected to shore.

  15. Check valve slam analysis in pumping station

    Science.gov (United States)

    Himr, D.; Habán, V.; Dokoupil, P.

    2016-03-01

    Pumping station supplies water for technological process. The check valve in the station was replaced with a new one. The regular test of black out discovered the high pressure pulsations accompanied with noticeable pipeline movement of discharge pipe. It was caused by late check valve closing, probably, when the back flow reached the highest possible velocity. This statement was supported with analysis of results of pressure measurement near the check valve and with a numerical simulation of the flow in the pipeline system.

  16. Efeitos de um programa de exercícios no desempenho de crianças nos testes de flexibilidade e impulsão vertical Effects of an exercise program on children's flexibility and vertical jump performance

    Directory of Open Access Journals (Sweden)

    Diogo Henrique Constantino Coledam

    2012-09-01

    Full Text Available Esse estudo investigou o efeito de um programa de exercícios na flexibilidade e impulsão vertical de escolares. 61 crianças (30 meninos foram divididas em Grupo Controle Masculino (GCM, Grupo Intervenção Masculino (GIM, Grupo Controle Feminino (GCF e Grupo Intervenção Feminino (GIF. O GIM e GIF foram submetidos a um programa de exercícios durante as aulas de Educação Física Escolar com duração de 12 semanas. Foram realizados os testes de "sentar-e-alcançar" e impulsão vertical anteriormente às 12 semanas e após o término deste programa. Os resultados indicaram que o GIF e o GIM aumentaram significativamente o desempenho nos testes de impulsão vertical e "sentar-e-alcançar" após o programa de intervenção (P0,05. O programa de intervenção utilizado nesse estudo foi eficiente em aumentar a flexibilidade e impulsão vertical de crianças.This study investigated the effects of an exercise training program on flexibility and vertical jump performance in children at scholar age. 61 Children (30 boys were divided in male control group (MCG, male intervention group (MIG, female control group (FCG and female intervention group (FIG. MIG and FIG were submitted to an exercise training program during physical education classes for 12 weeks. The "sit-and-reach" and vertical jump tests were performed before and after 12 weeks of the exercise training program. The results demonstrated that MIG and FIG groups significantly increased the performance on vertical jump as well as the "sit-and-reach" tests after the exercise training program (P0,05. The exercise program used in this study was efficient to increase flexibility and vertical jump performance in children.

  17. Evaluation of hydrostatic pressure tests with 'increased' test pressure at waste-fueled power stations; Bewertung von Druckpruefungen mit 'erhoehtem' Pruefdruck bei Muellheizkraftwerken

    Energy Technology Data Exchange (ETDEWEB)

    Baumann, Olaf; Schirmer, Ulrich [VGB PowerTech e.V., Essen (Germany); Herter, Karl-Heinz; Schuler, Xaver [Stuttgart Univ. (DE). Materialpruefungsanstalt (MPA)

    2010-07-01

    The essential safety requirements according to the pressure equipment directive (PED) also state specific quantitative requirements in terms of pressure testing (hydrostatic test) for the manufacturer to carry out within the scope of final assessment. In comparison to the pressure tests carried out up to now, aspects related to material-mechanical and safety-relevant points of view have to be considered if 'increased' pressure of the pressure test according to PED will be applied to recurrent pressure tests. Consequences resulting from ''increased'' pressure tests are demonstrated by taking waste incinerators as an example. (orig.)

  18. The Princess Elisabeth Station

    Science.gov (United States)

    Berte, Johan

    2012-01-01

    Aware of the increasing impact of human activities on the Earth system, Belgian Science Policy Office (Belspo) launched in 1997 a research programme in support of a sustainable development policy. This umbrella programme included the Belgian Scientific Programme on Antarctic Research. The International Polar Foundation, an organization led by the civil engineer and explorer Alain Hubert, was commissioned by the Belgian Federal government in 2004 to design, construct and operate a new Belgian Antarctic Research Station as an element under this umbrella programme. The station was to be designed as a central location for investigating the characteristic sequence of Antarctic geographical regions (polynia, coast, ice shelf, ice sheet, marginal mountain area and dry valleys, inland plateau) within a radius of 200 kilometers (approx.124 miles) of a selected site. The station was also to be designed as "state of the art" with respect to sustainable development, energy consumption, and waste disposal, with a minimum lifetime of 25 years. The goal of the project was to build a station and enable science. So first we needed some basic requirements, which I have listed here; plus we had to finance the station ourselves. Our most important requirement was that we decided to make it a zero emissions station. This was both a philosophical choice as we thought it more consistent with Antarctic Treaty obligations and it was also a logistical advantage. If you are using renewable energy sources, you do not have to bring in all the fuel.

  19. Pengujian sifat unggul beberapa klon harapan kopi arabika di kebun percobaan Andungsari, Jawa Timur (Testing for superior traits of some arabica coffee promising clones at Andungsari research station, East Java

    Directory of Open Access Journals (Sweden)

    Retno Hulupi

    2012-08-01

    Full Text Available One of the major diseases which limiting production in arabica coffee is the leaf rust caused by the fungus Hemileia vastatrix, B et Br. Selection and testing on thirteen promising arabica coffee clones were carried out at endemic area for leaf rust disease, Andungsari Research Station, for six fruiting times. The aims of these test were to find out superior planting material as clone with genetic resistance to leaf rust. As the beverage commodities, criterium selections for superiority clone besides resistant to leaf rust and yielding ability of more than 1,5 ton/ha also must be excellent in cup quality. Under this consideration, BP 416 A clone showed as the best high yielding ability i.e. 1,595 kg/ha and stable, besides resistant to leaf rust disease compared to the other clones tested. This clone had good cup quality, better than earlier released variety such as USDA 762 and S 795 although was not better than Andungsari 1 that were planted in the same location. The best physical bean characteristics was obtained on BP 513 A clone wich is derived from S 795 x Caturra red, having 89.2% of normal bean and 18.3% outurn characteristics. However, due to lower yielding and more susceptible to leaf rust, this clone could not be classified as superior clone.

  20. Offshore Metocean Station for Energy Purposes

    Directory of Open Access Journals (Sweden)

    Stefan Balluff

    2016-12-01

    Full Text Available Renewable energy concepts are able to sustainably satisfy the world energy demand without any restrictions for the following generations. In these concepts the wind energy and wave / current energy are important factors as the description and the prognosis of waves and currents is a complex issue, especially offshore. For the estimation of the average annual wind speed and thus the energy production of offshore wind farms it is imperative to know the exact wind conditions at each project site. Suitable prognosis methods are missing so far, are not accurate enough or at beta stage. The only possibility to achieve exact information about the offshore conditions is a metocean station consisting of wind and wave sensors. These met stations can be lattice masts mounted on monopiles or buoys equipped with meteorological sensors, both in combination with wave sensors to include all important parameters. Though conventional metocean stations are far more common, established and are measuring data of high quality, cheaper and more flexible solutions as the likes of floating Lidars (Light Detection And Ranging are about to be used during the operation of wind farms. This article explains currently used methods of measurements offshore with respect to wind and wave and compares it with reanalysis data. This data has advantages in comparison to measurements from conventional metocean stations, but cannot be used independently. This article proves that using solely reanalysis data is not possible, that measurements offshore are still necessary and that its operation helps improving the performance of offshore wind farms.

  1. cceptance tests on the turbine model for Feilaixia Hydropower Station and its parameter selection%飞来峡水电站水轮机模型验收试验与参数选择

    Institute of Scientific and Technical Information of China (English)

    游赞培

    2001-01-01

    飞来峡水电站的水轮机参数选择,经过了几个设计阶段的变更最终选用了奥地利的伊林-奥钢联公司的贯流式机组,其参数为15 m水头段的国际领先水平。水轮机通过模型验收试验,其模型最高效率达93.77%,而高效率区范围广且变化平缓;超低水头飞逸泄流性能试验在水头0.53~3.31 m范围内泄流量为保证值的121%~179%;压力脉动试验在飞逸泄流时其值偏大,但绝对值仅为0.37 m,能量较小对安全稳定泄流不会构成太大影响;导水叶力矩具有自关闭特性,对机组防飞逸具有较好的效果。飞来峡水轮机的参数选择和模型验收试验都达到了满意的结果。%The selection of the turbine's parameters for Feilaixia Hydropower Station has been changed in different design stages. Finally, the tubular generating unit made in Austria was selected, because its parameters is up to the international advanced level in the scope of water head of 15 m. The acceptance tests showed that the model has the highest efficiency of 93.77% and has wide high-efficiency area and smooth in its change. The runaway releasing performance test under the condition of super-low water head showed that the releasing volume is 121%~179% of guaranteed value within the water head of 0.53~3.31 m. The pressure pulse tests showed that the runaway releasing value is in the high side but its absolute value is only 0.37 m, which could not bring big impact on safe and stable releasing water. The force moment of guiding water blade has self-close function, which can effectively protect the runaway of generating unit. The parameter selection and model acceptance test of the Feilaixia Hydropower Station all have reached satisfied results.

  2. PHYSICAL SIMULATION & TEST

    Data.gov (United States)

    Federal Laboratory Consortium — Crew Station/Turret Motion Based Simulator (CS/TMBS) Test station simulates operational scenarios The CS/TMBS is a high-capacity six-degrees-of-freedom test device....

  3. Test Station Flywheel System Optimization Design and Finite Element Analysis%试验台飞轮系统优化设计与有限元分析

    Institute of Scientific and Technical Information of China (English)

    任永强; 李新恒

    2013-01-01

    基于惯量模拟对同步器换挡耐久试验台的飞轮系统进行了结构设计,在满足转动惯量要求的前提下,以飞轮质量最小为目标,利用最优设计理论对飞轮结构参数进行了计算.基于优化结果,通过有限元仿真对飞轮系统进行了静力和模态分析,仿真结果表明优化的结构满足飞轮系统的强度和动力学要求,能够安全可靠的工作.%The structure of the flywheel system on test rig of shifting durability of synchroniser is designed based on the inertia simulation.Satisfied with the request of the inertia moment,structural parameters of the flywheel system are calculated to minimize the flywheel mass using optimization theory.By the static and modal analysis using the FEM,the simulation results indicate that the optimized structures can meet the demands for the strength and dynamics of the flywheel system,which leads to safe and stable work.

  4. Flexible, ab initio potential, and dipole moment surfaces for water. I. Tests and applications for clusters up to the 22-mer.

    Science.gov (United States)

    Wang, Yimin; Huang, Xinchuan; Shepler, Benjamin C; Braams, Bastiaan J; Bowman, Joel M

    2011-03-07

    We report full-dimensional, ab initio potential energy and dipole moment surfaces, denoted PES and DMS, respectively, for arbitrary numbers of water monomers. The PES is a sum of 1-, 2-, and 3-body potentials which can also be augmented by semiempirical long-range higher-body interactions. The 1-body potential is a spectroscopically accurate monomer potential, and the 2- and 3-body potentials are permutationally invariant fits to tens of thousands of CCSD(T)/aug-cc-pVTZ and MP2/aug-cc-pVTZ electronic energies, respectively. The DMS is a sum of 1- and 2-body DMS, which are covariant fits to tens of thousands MP2/aug-cc-pVTZ dipole moment data. We present the details of these new 2- and 3-body potentials and then extensive applications and tests of this PES are made to the structures, classical binding energies, and harmonic frequencies of water clusters up to the 22-mer. In addition, we report the dipole moment for these clusters at various minima and compare the results against available and new ab initio calculations.

  5. Environmental interactions on Space Station

    Science.gov (United States)

    Garrett, Henry B.; Gabriel, Stephen B.; Murphy, Gerald B.

    1990-01-01

    This paper describes the key environment/system interactions associated with the Space Station and its companion polar platform and defines the range of test environments that will need to be simulated. These environments include the neutral atmosphere, the ionospheric plasma, natural and man-made particulates, the ambient magnetic field, the South Atlantic Anomaly, and the ram/wake environment. The system/environment interactions include glow, oxygen erosion, drag, radiation effects, induced electric fields, high-voltage solar-array effects, and EMC/EMI associated with plasma/neutral gas operations. The Space Station and its associated systems pose unique demands on the ability to simulate these effects; synergistic effects require multiple environments to be simulated simultaneously, and the long life requirements require proper scaling of the exposure time. The analysis of specific effects and the calibration or improvement of ground test techniques will likely require in situ evaluation. Qualification and acceptance testing, because of cost and the impractically of extensive on-orbit analysis/modification, will likely remain ground test objectives except in very rare cases.

  6. Toluene stability Space Station Rankine power system

    Science.gov (United States)

    Havens, V. N.; Ragaller, D. R.; Sibert, L.; Miller, D.

    1987-01-01

    A dynamic test loop is designed to evaluate the thermal stability of an organic Rankine cycle working fluid, toluene, for potential application to the Space Station power conversion unit. Samples of the noncondensible gases and the liquid toluene were taken periodically during the 3410 hour test at 750 F peak temperature. The results obtained from the toluene stability loop verify that toluene degradation will not lead to a loss of performance over the 30-year Space Station mission life requirement. The identity of the degradation products and the low rates of formation were as expected from toluene capsule test data.

  7. Flexible magnetoimpedance sensor

    Energy Technology Data Exchange (ETDEWEB)

    Li, Bodong; Kavaldzhiev, Mincho N.; Kosel, Jürgen, E-mail: jurgen.kosel@kaust.edu.sa

    2015-03-15

    Flexible magnetoimpedance (MI) sensors fabricated using a NiFe/Cu/NiFe tri-layer on Kapton substrate have been studied. A customized flexible microstrip transmission line was employed to investigate the MI sensors's magnetic field and frequency responses and their dependence on the sensors's deflection. For the first time, the impedance characteristic is obtained through reflection coefficient analysis over a wide range of frequencies from 0.1 MHz to 3 GHz and for deflections ranging from zero curvature to a radius of 7.2 cm. The sensor element maintains a high MI ratio of up to 90% and magnetic sensitivity of up to 9.2%/Oe over different bending curvatures. The relationship between the curvature and material composition is discussed based on the magnetostriction effect and stress simulations. The sensor's large frequency range, simple fabrication process and high sensitivity provide a great potential for flexible electronics and wireless applications. - Highlights: • A flexible magnetoimpedance (MI) sensor is developed. • Studies are carried out using a flexible microstrip transmission line. • An MI ratio of up to 90% is obtained. • The effect of magnetostriction is studied.

  8. Design of Sound Absorber of Urban Rail way Station and Its Performance Testing%适用于城市轨道交通车站的吸声体设计及其性能测试

    Institute of Scientific and Technical Information of China (English)

    徐文君; 李双

    2012-01-01

    根据城市轨道交通车站的结构特点和噪声特性,设计并制作有空腔的吸声体;将1/4波长声管设置于吸声体中,以提高其对中低频轮轨噪声的吸收能力.通过单传声器脉冲响应法测试吸声体样品的吸声性能,结果表明:加装空腔和布置声管后,吸声体的中低频吸声能力明显提高.最后应用ANSYS和SYSNOISE软件,分别计算出安装该吸声体前后的车站声场,结果显示:安装吸声体后,候车点的声压降低2~5dB.%Based on the structural and noise characteristics of urban railway stations, a sound absorber with wooden cavity structure was designed and 1/4 wavelength sound tube was installed in the absorber to increase its absorption capacity for the noises of middle and low frequencies. The Impulse Response Method (IRM) with single microphone was used to test the sound absorber' s absorption coefficient. The result shows that absorption capacity of the absorber for the noise of low and middle frequencies is greatly enhanced after the cavity and sound tube have been placed in. The sound fields of an urban rail transit station before and after sound absorber installation was calculated respectively by means of the software ANSYS and SYSNOISE. The results show that sound pressure of waiting point on the platform can be reduced by 2 -5 dB.

  9. Flexible experimental FPGA based platform

    DEFF Research Database (Denmark)

    Andersen, Karsten Holm; Nymand, Morten

    2016-01-01

    This paper presents an experimental flexible Field Programmable Gate Array (FPGA) based platform for testing and verifying digital controlled dc-dc converters. The platform supports different types of control strategies, dc-dc converter topologies and switching frequencies. The controller platform...... interface supporting configuration and reading of setup parameters, controller status and the acquisition memory in a simple way. The FPGA based platform, provides an easy way within education or research to use different digital control strategies and different converter topologies controlled by an FPGA...

  10. Versatile Flexible Graphene Multielectrode Arrays.

    Science.gov (United States)

    Kireev, Dmitry; Seyock, Silke; Ernst, Mathis; Maybeck, Vanessa; Wolfrum, Bernhard; Offenhäusser, Andreas

    2016-12-23

    Graphene is a promising material possessing features relevant to bioelectronics applications. Graphene microelectrodes (GMEAs), which are fabricated in a dense array on a flexible polyimide substrate, were investigated in this work for their performance via electrical impedance spectroscopy. Biocompatibility and suitability of the GMEAs for extracellular recordings were tested by measuring electrical activities from acute heart tissue and cardiac muscle cells. The recordings show encouraging signal-to-noise ratios of 65 ± 15 for heart tissue recordings and 20 ± 10 for HL-1 cells. Considering the low noise and excellent robustness of the devices, the sensor arrays are suitable for diverse and biologically relevant applications.

  11. Versatile Flexible Graphene Multielectrode Arrays

    Directory of Open Access Journals (Sweden)

    Dmitry Kireev

    2016-12-01

    Full Text Available Graphene is a promising material possessing features relevant to bioelectronics applications. Graphene microelectrodes (GMEAs, which are fabricated in a dense array on a flexible polyimide substrate, were investigated in this work for their performance via electrical impedance spectroscopy. Biocompatibility and suitability of the GMEAs for extracellular recordings were tested by measuring electrical activities from acute heart tissue and cardiac muscle cells. The recordings show encouraging signal-to-noise ratios of 65 ± 15 for heart tissue recordings and 20 ± 10 for HL-1 cells. Considering the low noise and excellent robustness of the devices, the sensor arrays are suitable for diverse and biologically relevant applications.

  12. Fully Integral, Flexible Composite Driveshaft

    Science.gov (United States)

    Lawrie, Duncan

    2014-01-01

    An all-composite driveshaft incorporating integral flexible diaphragms was developed for prime contractor testing. This new approach makes obsolete the split lines required to attach metallic flex elements and either metallic or composite spacing tubes in current solutions. Subcritical driveshaft weights can be achieved that are half that of incumbent technology for typical rotary wing shaft lengths. Spacing tubes compose an integral part of the initial tooling but remain part of the finished shaft and control natural frequencies and torsional stability. A concurrently engineered manufacturing process and design for performance competes with incumbent solutions at significantly lower weight and with the probability of improved damage tolerance and fatigue life.

  13. Flexible magnetoimpedance sensor

    KAUST Repository

    Li, Bodong

    2015-03-01

    Flexible magnetoimpedance (MI) sensors fabricated using a NiFe/Cu/NiFe tri-layer on Kapton substrate have been studied. A customized flexible microstrip transmission line was employed to investigate the MI sensors\\'s magnetic field and frequency responses and their dependence on the sensors\\'s deflection. For the first time, the impedance characteristic is obtained through reflection coefficient analysis over a wide range of frequencies from 0.1 MHz to 3 GHz and for deflections ranging from zero curvature to a radius of 7.2 cm. The sensor element maintains a high MI ratio of up to 90% and magnetic sensitivity of up to 9.2%/Oe over different bending curvatures. The relationship between the curvature and material composition is discussed based on the magnetostriction effect and stress simulations. The sensor\\'s large frequency range, simple fabrication process and high sensitivity provide a great potential for flexible electronics and wireless applications.

  14. Pneumatic flexible shaft couplings

    Directory of Open Access Journals (Sweden)

    Jaroslav HOMIŠIN

    2007-01-01

    Full Text Available Main effort of every design engineer is reduction of torsional oscillation in any mechanical system. At present this problem can be solved by means of a suitable modification of dynamic properties of flexible shaft couplings according to dynamics in the given systems. But the dynamic properties of nowadays-applied flexible couplings arenot unchangeable because of aging and fatigue processes occurring in flexible coupling elements. Result of this fact causes detuning of mechanical system. Taking into consideration the above-mentioned situation, we suggest for mechanical systems application of a newly developed pneumatic couplings that have constant characteristicfeatures during the whole current operation and thus they have a positive influence on the system running.

  15. Designing structural supply chain flexibility

    OpenAIRE

    Mulinski, Ksawery Jan

    2012-01-01

    In a continuously changing business environment the role of supply chain flexibility is constantly increasing. A flexible supply chain can ensure survival in quickly changing market conditions as well as enable sustainable growth. This thesis explores the topic of supply chain flexibility with focus on structural flexibility due to scarcity of previous research in that area. The purpose of the research is to answer a question: how can companies design structural supply chain flexibility? In a...

  16. Modelling the Implications of Quality Management Elements on Strategic Flexibility

    Directory of Open Access Journals (Sweden)

    Ana Belén Escrig-Tena

    2011-01-01

    Full Text Available This paper presents a theoretical and empirical analysis of the implications of a quality management (QM initiative on strategic flexibility. Our study defines flexibility from a strategic approach and examines the extent to which, why, and how the triggering factors of strategic flexibility are related to QM elements. The hypotheses put forward are tested in an empirical study carried out on a sample of Spanish firms, using structural equation models. The results demonstrate the positive effect of adopting an integral QM initiative on enhancing strategic flexibility. QM enhances strategic flexibility more effectively when it is introduced comprehensively rather than in a piecemeal fashion. A series of practices linked to the application of a QM initiative are outlined, which managers can use to improve strategic flexibility. The approach used in the study can be applied to analyse other antecedents of flexibility and to propose possible studies that consider QM as an antecedent of other organisational variables.

  17. Outdoor Field Experience with Autonomous Stations

    CERN Document Server

    Lopes, L; Blanco, A; Carolino, N; Cerda, M A; Conceicao, R; Cunha, O; Ferreira, M; Fonte, P; Luz, R; Mendes, L; Pereira, A; Pimenta, M; Sarmento, R; Tome, B

    2016-01-01

    In the last two decades Resistive Plate Chambers were employed in the Cosmic Ray Experiments COVER-PLASTEX and ARGO/YBJ. In both experiments the detectors were housed indoors, likely owing to gas distribution requirements and the need to control environment variables that directly affect RPCs operational stability. But in experiments where Extended Air Shower (EAS) sampling is necessary, large area arrays composed by dispersed stations are deployed, rendering this kind of approach impossible. In this situation, it would be mandatory to have detectors that could be deployed in small standalone stations, with very rare opportunities for maintenance, and with good resilience to environmental conditions. Aiming to meet these requirements, we started some years ago the development of RPCs for Autonomous Stations. The results from indoor tests and measurements were very promising, both concerning performance and stability under very low gas flow rate, which is the main requirement for Autonomous Stations. In this w...

  18. Hydrogen Fuelling Stations

    DEFF Research Database (Denmark)

    Rothuizen, Erasmus Damgaard

    This thesis concerns hydrogen fuelling stations from an overall system perspective. The study investigates thermodynamics and energy consumption of hydrogen fuelling stations for fuelling vehicles for personal transportation. For the study a library concerning the components in a hydrogen fuelling...... station has been developed in Dymola. The models include the fuelling protocol (J2601) for hydrogen vehicles made by Society of Automotive Engineers (SAE) and the thermodynamic property library CoolProp is used for retrieving state point. The components in the hydrogen fuelling library are building up....... A system consisting of one high pressure storage tank is used to investigate the thermodynamics of fuelling a hydrogen vehicle. The results show that the decisive parameter for how the fuelling proceeds is the pressure loss in the vehicle. The single tank fuelling system is compared to a cascade fuelling...

  19. Establishing and Testing of Wireless Transmission System Based on Knitted Flexible Sensor%基于针织柔性传感器无线传输系统构建与测试

    Institute of Scientific and Technical Information of China (English)

    易红霞; 龙海如; 李家成

    2015-01-01

    In view of the command of wearable,highly reliable,low power consumption and wireless information transmission,knitted flexible fabric in integrated intelligent cloth with silver conductive yarns was presented in this paper. Based on the ZigBee wireless network, the signal transmission system between terminal node and coordinator node was established. A circuit was designed to ensure that the knitted flexible sensor was linked to the terminal node, then joined the ZigBee network, and the human physiological signal gathered by the senor integrated intelli-gent cloth was transmitted to coordinate node by serial communication. The MSComm controls of Visual Basic 6.0 realized the communication between coordinate node and upper computer, and the human physiological signal in the form of sensor voltage change curve was displayed real-time by using related functions. The results of tensile test and signal acquisition test show that this kind of method is feasible.%基于可穿戴、高可靠、低功耗和信息无线传输的要求,提出采用镀银导电纱线编织针织柔性传感器集成在智能服装上,构建基于ZigBee的无线网络以及终端节点和协调器节点之间的无线信号传输系统;将采集到的人体生理信号通过串口通信传输到协调器节点,然后通过Visual Basic 6.0的MSComm控件实现协调器节点与上位机之间的通信,并调用相关函数实时显示采集到的传感器电压变化曲线,从而反映出人体生理信号的变化。拉伸试验和呼吸信号采集试验验证了该方案的可行性。

  20. Investigation and flight tests on control and stability of aircraft with after-mounted propeller and flexible wing%螺旋桨推进式柔性翼飞机操稳特性研究与试飞

    Institute of Scientific and Technical Information of China (English)

    吴大卫; 吴征; 张兰丁; 邓彦敏

    2011-01-01

    Small scale aircraft with flexible wing is relatively popular among utility aircrafts and in some special fields, but there are still confusions in conceptual design which is mainly according to experiences. These aircrafts u sually have the configuration of high wing with flexible fabric skin and after-mounted propeller, therefore the charac ters of aerodynamics, layout and power effect bring about some prominent particularities in flight dynamics. According to aerodynamic prediction, wind tunnel tests and flight tests, this paper shows some conclusions about longitudinal/ lateral contol and stability different from conventional aircrafts and gives the physical explanations for the results, then supplies the suitable methods of modeling these aircrafts for analyzing flight dynamics and recommends a series of range for designing parameters different from other conventional aircrafts.%采用柔性翼面的小型飞行器在通用航空器和特种飞行器领域得到了较广泛的应用.由于此类飞行器往往采用蒙皮为可变形柔性织物的高置上单翼以及推进式螺旋桨,其特殊的升阻特性、总体布局和动力影响使得其飞行动力学具有很大特殊性.结合气动力估算、风洞实验和飞行实验结果,在此类飞机的纵、横航向操纵性与稳定性方面得出了有别于传统飞机的一些结论,并给出了有关物理解释;提供了适合此类飞机的飞行动力学建模方法和一系列有别于传统飞机的设计参数取值范围.

  1. Study of the mechanical properties of the electric power station components: the punch test; Etude des proprietes mecaniques des composants de centrales thermiques: l'essai punch test

    Energy Technology Data Exchange (ETDEWEB)

    Isselin, J

    2003-03-15

    The aging of the electric production park implies an increasing need of knowledge concerning the evolution of the mechanical properties of its components. With regard to this problem, the availability in material is more and more small. This work proposes to characterize these properties through a mechanical test called Punch test. The main characteristic of this test is to use very small volume samples. The development of this test has been carried out by the study of a 15 MDV 4-05 steel coming from a steam drum of a thermal power plant after 145000 hours of service. At first, we have measured the influence of the parameters of this test. Then, the study has dealt more particularly on the transition temperature of the material. With the finite element simulation method, the strain hardening coefficient of the material has been determined. (O.M.)

  2. Hydrogen vehicle fueling station

    Energy Technology Data Exchange (ETDEWEB)

    Daney, D.E.; Edeskuty, F.J.; Daugherty, M.A. [Los Alamos National Lab., NM (United States)] [and others

    1995-09-01

    Hydrogen fueling stations are an essential element in the practical application of hydrogen as a vehicle fuel, and a number of issues such as safety, efficiency, design, and operating procedures can only be accurately addressed by a practical demonstration. Regardless of whether the vehicle is powered by an internal combustion engine or fuel cell, or whether the vehicle has a liquid or gaseous fuel tank, the fueling station is a critical technology which is the link between the local storage facility and the vehicle. Because most merchant hydrogen delivered in the US today (and in the near future) is in liquid form due to the overall economics of production and delivery, we believe a practical refueling station should be designed to receive liquid. Systems studies confirm this assumption for stations fueling up to about 300 vehicles. Our fueling station, aimed at refueling fleet vehicles, will receive hydrogen as a liquid and dispense it as either liquid, high pressure gas, or low pressure gas. Thus, it can refuel any of the three types of tanks proposed for hydrogen-powered vehicles -- liquid, gaseous, or hydride. The paper discusses the fueling station design. Results of a numerical model of liquid hydrogen vehicle tank filling, with emphasis on no vent filling, are presented to illustrate the usefulness of the model as a design tool. Results of our vehicle performance model illustrate our thesis that it is too early to judge what the preferred method of on-board vehicle fuel storage will be in practice -- thus our decision to accommodate all three methods.

  3. Flexible energy systems

    DEFF Research Database (Denmark)

    Lund, Henrik

    2003-01-01

    The paper discusses and analyses diffent national strategies and points out key changes in the energy system in order to achieve a system which can benefit from a high percentage of wind and CHP without having surplus production problems, introduced here as a flexible energy system....

  4. Flexible Classroom Furniture

    Science.gov (United States)

    Kim Hassell,

    2011-01-01

    Classroom design for the 21st-century learning environment should accommodate a variety of learning skills and needs. The space should be large enough so it can be configured to accommodate a number of learning activities. This also includes furniture that provides flexibility and accommodates collaboration and interactive work among students and…

  5. Flexible Language Interoperability

    DEFF Research Database (Denmark)

    Ekman, Torbjörn; Mechlenborg, Peter; Schultz, Ulrik Pagh

    2007-01-01

    of the language. In this paper, we present a highly flexible yet efficient approach to hosting multiple programming languages on an object-oriented virtual machine. Our approach is based on extending the interface of each class with language-specific wrapper methods, offering each language a tailored view...

  6. Flexible Mental Calculation.

    Science.gov (United States)

    Threlfall, John

    2002-01-01

    Suggests that strategy choice is a misleading characterization of efficient mental calculation and that teaching mental calculation methods as a whole is not conducive to flexibility. Proposes an alternative in which calculation is thought of as an interaction between noticing and knowledge. Presents an associated teaching approach to promote…

  7. Flexible cultural repertoires

    DEFF Research Database (Denmark)

    Lindegaard, Marie Rosenkrantz; Zimmermann, Francisca

    2017-01-01

    rejection of crime-involved youth. Young men who perform flexible cultural repertoires, by incorporating and shifting between gang and decent repertoires, experience low victimization due to their adaptation to crime-involved youth. Findings emphasize the importance of detailed investigations of the way...

  8. Flexible Query Answering Systems

    DEFF Research Database (Denmark)

    This book constitutes the refereed proceedings of the 12th International Conference on Flexible Query Answering Systems, FQAS 2017, held in London, UK, in June 2017. The 21 full papers presented in this book together with 4 short papers were carefully reviewed and selected from 43 submissions...

  9. GPS Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Global Positioning System (GPS) Test Facility Instrumentation Suite (GPSIS) provides great flexibility in testing receivers by providing operational control of...

  10. 静态应变测试系统在向家坝水电站地弄荷载试验中的应用%Application of Static Strain Testing System in Aggregate Transport Gallery Load Test of Xiangjiaba Hydropower Station

    Institute of Scientific and Technical Information of China (English)

    丁长青

    2011-01-01

    采用应变片法现场测试结构实际承载能力在工程上已得到广泛的应用.文中通过静态应变测试系统配合沉降观测、挠度观测介绍了向家坝地弄荷载试验情况和最后成果,为向家坝料场堆场地弄的安全运行提供了可靠依据.%The method to use the strain gauge technique to test the actual structural bearing capacity has been widely used in projects. The situation and final results of aggregate transport gallery load test of Xiangjiaba hydropower station are introduced by means of the static strain testing system combined with the settlement observation and deflection observation. It provide a reliable basis for the safe operation of aggregate transport gallery of Xiangjiaba hydropower station.

  11. International Space Station Crew Restraint Design

    Science.gov (United States)

    Whitmore, M.; Norris, L.; Holden, K.

    2005-01-01

    With permanent human presence onboard the International Space Station (ISS), crews will be living and working in microgravity, dealing with the challenges of a weightless environment. In addition, the confined nature of the spacecraft environment results in ergonomic challenges such as limited visibility and access to the activity areas, as well as prolonged periods of unnatural postures. Without optimum restraints, crewmembers may be handicapped for performing some of the on-orbit tasks. Currently, many of the tasks on ISS are performed with the crew restrained merely by hooking their arms or toes around handrails to steady themselves. This is adequate for some tasks, but not all. There have been some reports of discomfort/calluses on the top of the toes. In addition, this type of restraint is simply insufficient for tasks that require a large degree of stability. Glovebox design is a good example of a confined workstation concept requiring stability for successful use. They are widely used in industry, university, and government laboratories, as well as in the space environment, and are known to cause postural limitations and visual restrictions. Although there are numerous guidelines pertaining to ventilation, seals, and glove attachment, most of the data have been gathered in a 1-g environment, or are from studies that were conducted prior to the early 1980 s. Little is known about how best to restrain a crewmember using a glovebox in microgravity. In 2004, The Usability Testing and Analysis Facility (UTAF) at the NASA Johnson Space Center completed development/evaluation of several design concepts for crew restraints to meet the various needs outlined above. Restraints were designed for general purpose use, for teleoperation (Robonaut) and for use with the Life Sciences Glovebox. All design efforts followed a human factors engineering design lifecycle, beginning with identification of requirements followed by an iterative prototype/test cycle. Anthropometric

  12. INTERACT Station Catalogue - 2015

    DEFF Research Database (Denmark)

    INTERACT stations are located in all major environmental envelopes of the Arctic providing an ideal platform for studying climate change and its impact on the environment and local communities. Since alpine environments face similar changes and challenges as the Arctic, the INTERACT network also ...

  13. Electrostatic pickup station

    CERN Multimedia

    CERN PhotoLab

    1979-01-01

    Electrostatic pickup station, with 4 electrodes, to measure beam position in the horizontal and vertical plane. This type is used in the transfer lines leaving the PS (TT2, TTL2, TT70). See also 8206063, where the electrode shapes are clearly visible.

  14. Kiowa Creek Switching Station

    Energy Technology Data Exchange (ETDEWEB)

    1990-03-01

    The Western Area Power Administration (Western) proposes to construct, operate, and maintain a new Kiowa Creek Switching Station near Orchard in Morgan County, Colorado. Kiowa Creek Switching Station would consist of a fenced area of approximately 300 by 300 feet and contain various electrical equipment typical for a switching station. As part of this new construction, approximately one mile of an existing 115-kilovolt (kV) transmission line will be removed and replaced with a double circuit overhead line. The project will also include a short (one-third mile) realignment of an existing line to permit connection with the new switching station. In accordance with the Council on Environmental Quality (CEQ) regulations for implementing the procedural provisions of the National Environmental Policy Act of 1969 (NEPA), 40 CFR Parts 1500--1508, the Department of Energy (DOE) has determined that an environmental impact statement (EIS) is not required for the proposed project. This determination is based on the information contained in this environmental assessment (EA) prepared by Western. The EA identifies and evaluates the environmental and socioeconomic effects of the proposed action, and concludes that the advance impacts on the human environment resulting from the proposed project would not be significant. 8 refs., 3 figs., 1 tab.

  15. Designing a Weather Station

    Science.gov (United States)

    Roman, Harry T.

    2012-01-01

    The collection and analysis of weather data is crucial to the location of alternate energy systems like solar and wind. This article presents a design challenge that gives students a chance to design a weather station to collect data in advance of a large wind turbine installation. Data analysis is a crucial part of any science or engineering…

  16. Summit Station Skiway Review

    Science.gov (United States)

    2013-03-01

    operating procedures (SOPs) for future construction and maintenance efforts. DISCLAIMER: The contents of this report are not to be used for...Runway Construction .......................................................... 22 Appendix B: Rammsonde Instructions...13. Snow accumulation at Summit Station in the Bamboo Forest. .......................................... 13 Figure 14. Strength of Summit skiway

  17. Galileo Station Keeping Strategy

    Science.gov (United States)

    Perez-Cambriles, Antonio; Bejar-Romero, Juan Antonio; Aguilar-Taboada, Daniel; Perez-Lopez, Fernando; Navarro, Daniel

    2007-01-01

    This paper presents analyses done for the design and implementation of the Maneuver Planning software of the Galileo Flight Dynamics Facility. The station keeping requirements of the constellation have been analyzed in order to identify the key parameters to be taken into account in the design and implementation of the software.

  18. Kiowa Creek Switching Station

    Energy Technology Data Exchange (ETDEWEB)

    1990-03-01

    The Western Area Power Administration (Western) proposes to construct, operate, and maintain a new Kiowa Creek Switching Station near Orchard in Morgan County, Colorado. Kiowa Creek Switching Station would consist of a fenced area of approximately 300 by 300 feet and contain various electrical equipment typical for a switching station. As part of this new construction, approximately one mile of an existing 115-kilovolt (kV) transmission line will be removed and replaced with a double circuit overhead line. The project will also include a short (one-third mile) realignment of an existing line to permit connection with the new switching station. In accordance with the Council on Environmental Quality (CEQ) regulations for implementing the procedural provisions of the National Environmental Policy Act of 1969 (NEPA), 40 CFR Parts 1500--1508, the Department of Energy (DOE) has determined that an environmental impact statement (EIS) is not required for the proposed project. This determination is based on the information contained in this environmental assessment (EA) prepared by Western. The EA identifies and evaluates the environmental and socioeconomic effects of the proposed action, and concludes that the advance impacts on the human environment resulting from the proposed project would not be significant. 8 refs., 3 figs., 1 tab.

  19. A Method of Unbalanced Current Off-line Test for High-voltage Capacitors in Converter Station%换流站高压电容器不平衡电流离线测试方法

    Institute of Scientific and Technical Information of China (English)

    吴鹏; 摆亲; 刘志远; 张振宇

    2014-01-01

    对换流站高压电容器不平衡电流理论计算进行简单推导,并以不同工频电压作用下不平衡电流的线性关系为基本原理,介绍了低工频电压下离线试验测试不平衡电流大小与理论计算值之间的差别,并通过对误差由浅入深地分析,从而得出现场运行维护人员提高不平衡电流测试值准确性的关键方法,即合理优化现场试验接线以减少电磁干扰,并适当对比理论计算值与离线试验测试值的方法,从而确保桥臂不平衡电流离线测试值的准确性。通过电容器调整或更换,满足了离线测试不平衡电流大小要求,能保障设备投入电网后的稳定运行。%This paper describes the unbalanced current theoretical formula of the high-voltage capacitors in a converter station, and with the linear relationship of unbalanced current under the action of different power frequency voltages as the basic principle,the difference between the unbalanced current theoretical value and off-line testing value under low power frequency voltage is accounted for.Through analysis of the cause of the difference from shallow to deep,the conclusion is reached that the key method by which the field maintenance personnel can improve the accuracy of unbalanced current test is through rational and optimized test wiring to reduce electromagnetic interference and appropriately compare theoretical value with off-line test value to ensure the accuracy of the bridge arm unbalanced current off-line test value.Through the capacitor adj ustment or replacement,the off-line test values of the unbalanced current are up to requirement for ensuring stable equipment work in operation.

  20. Soft Encapsulation of Flexible Electrical Stimulation Implant: Challenges and Innovations

    Directory of Open Access Journals (Sweden)

    Adrien Debelle

    2016-11-01

    Full Text Available In this document we discuss the main challenges encountered when producing flexible electrical stimulation implants, and present our approach to solving them for prototype production. We include a study of the optimization of the flexible PCB design, the selection of additive manufacturing materials for the mold, and the chemical compatibility of the different materials. Our approach was tested on a flexible gastro-stimulator as part of the ENDOGES research program.

  1. Adding flexibility to physician training.

    Science.gov (United States)

    Mahady, Suzanne E

    2011-05-02

    Demographic changes among junior doctors are driving demand for increased flexibility in advanced physician training, but flexible training posts are lacking. Suitable flexible training models include flexible full-time, job-share and part-time positions. Major barriers to establishing flexible training positions include difficulty in finding job-share partners, lack of funding for creating supernumerary positions, and concern over equivalence of educational quality compared with full-time training. Pilot flexible training positions should be introduced across the medical specialties and educational outcomes examined prospectively.

  2. Aggregating energy flexibilities under constraints

    DEFF Research Database (Denmark)

    Valsomatzis, Emmanouil; Pedersen, Torben Bach; Abello, Alberto

    2016-01-01

    The flexibility of individual energy prosumers (producers and/or consumers) has drawn a lot of attention in recent years. Aggregation of such flexibilities provides prosumers with the opportunity to directly participate in the energy market and at the same time reduces the complexity of scheduling...... the energy units. However, aggregated flexibility should support normal grid operation. In this paper, we build on the flex-offer (FO) concept to model the inherent flexibility of a prosumer (e.g., a single flexible consumption device such as a clothes washer). An FO captures flexibility in both time...

  3. Space station operating system study

    Science.gov (United States)

    Horn, Albert E.; Harwell, Morris C.

    1988-01-01

    The current phase of the Space Station Operating System study is based on the analysis, evaluation, and comparison of the operating systems implemented on the computer systems and workstations in the software development laboratory. Primary emphasis has been placed on the DEC MicroVMS operating system as implemented on the MicroVax II computer, with comparative analysis of the SUN UNIX system on the SUN 3/260 workstation computer, and to a limited extent, the IBM PC/AT microcomputer running PC-DOS. Some benchmark development and testing was also done for the Motorola MC68010 (VM03 system) before the system was taken from the laboratory. These systems were studied with the objective of determining their capability to support Space Station software development requirements, specifically for multi-tasking and real-time applications. The methodology utilized consisted of development, execution, and analysis of benchmark programs and test software, and the experimentation and analysis of specific features of the system or compilers in the study.

  4. An Annotated Bibliography of High-Voltage Direct-Current Transmission and Flexible AC Transmission (FACTS) Devices, 1991-1993.

    Energy Technology Data Exchange (ETDEWEB)

    Litzenberger, Wayne; Lava, Val

    1994-08-01

    References are contained for HVDC systems, converter stations and components, overhead transmission lines, cable transmission, system design and operations, simulation of high voltage direct current systems, high-voltage direct current installations, and flexible AC transmission system (FACTS).

  5. 溪洛渡水电站导流洞卵石推移质测验简介%An Introduction of Gravel Bed-load Testing in the Diversion Tunnel of Xiluodu Hydropower Station

    Institute of Scientific and Technical Information of China (English)

    杨世林

    2014-01-01

    为了寻找溪洛渡导流洞混凝土及钢筋磨损原因,采用缆道悬挂大型采样器方式,在导流洞出口开展卵石推移质试验观测,因此取得通过导流洞的推移质样品,为研究解决导流洞抗磨蚀问题收集了观测成果,也为金沙江后续电站的科研设计提供了有益的资料。%In order to find the reason why concretes and steel bars in the diversion tunnel of Xiluodu were worn out ,this paper introduces a way in which large‐scale samplers suspended on cableways are used to do gravel bed‐load testing at the exit of diversion tunnel .By obtaining gravel bed‐load samples ,this method not only collects valuable information to solve the abrasion problem in diversion tunnels ,but also serves as an essential reference for the design of subsequent hydropower stations in Jinsha River .

  6. Blasting Test and Study on Dam Filling with Moraine Gravel in Jiangpinghe Hydropower Station%江坪河水电站堆石坝冰渍砾岩筑坝料爆破试验研究

    Institute of Scientific and Technical Information of China (English)

    严匡柠; 邹文明; 朱贤博

    2011-01-01

    Concrete face rockfill dam is adopted in Jiangpinghe Hydropower Station. The height of dam is 219m, which is filled with moraine gravel. In view of the special property of moraine gravel, tentative blasting parameters are decided. Then a completed blasting test has been continued for optimizing blasting parameters to improve the gradation of dam filling combining with blasting construction on site.%江坪河水电站采用混凝土面板堆石坝,坝体高度219m,用冰渍砾岩填筑高面板堆石坝.鉴于冰渍砾岩的特殊性,在已有爆破试验成果的基础上,初拟爆破参数.结合现场爆破开采施工试验成果,进一步深入研究,优化了可改善坝料级配的爆破参数.

  7. GPP-Based Soft Base Station Designing and Optimization

    Institute of Scientific and Technical Information of China (English)

    Xiao-Feng Tao; Yan-Zhao Hou; Kai-Dong Wang; Hai-Yang He; Y.Jay Guo

    2013-01-01

    It is generally acknowledged that mobile communication base stations are composed of hardware components such as Field Programming Gate Array (FPGA),Digital Signal Processor (DSP),which promise reliable and fluent services for the mobile users.However,with the increasing demand for energy-efficiency,approaches of low power-consumption and high-flexibility are needed urgently.In this circumstance,General Purpose Processor (GPP) attracts people's attention for its low-cost and flexibility.Benefited from the development of modern GPP in multi-core,Single Instruction Multiple Data (SIMD) instructions,larger cache,etc.,GPPs are capable of performing high-density digital processing.In this paper,we compare several software-defined radio (SDR) prototypes and propose the general architecture of GPP-based soft base stations.Then,the schematic design of resource allocation and algorithm optimization in soft base station implementation are studied.As an application example,a prototype of GPP-based soft base station referring to the 3rd Generation Partnership Project (3GPP) Long Term Evolution (LTE) is realized and evaluated.To the best of our knowledge,it is the first Soft-LTE prototype ever reported.In the end,we evaluate the timing performance of the LTE soft base station and a packet loss ratio of less than 0.003 is obtained.

  8. Hydrogen Filling Station

    Energy Technology Data Exchange (ETDEWEB)

    Boehm, Robert F; Sabacky, Bruce; Anderson II, Everett B; Haberman, David; Al-Hassin, Mowafak; He, Xiaoming; Morriseau, Brian

    2010-02-24

    Hydrogen is an environmentally attractive transportation fuel that has the potential to displace fossil fuels. The Freedom CAR and Freedom FUEL initiatives emphasize the importance of hydrogen as a future transportation fuel. Presently, Las Vegas has one hydrogen fueling station powered by natural gas. However, the use of traditional sources of energy to produce hydrogen does not maximize the benefit. The hydrogen fueling station developed under this grant used electrolysis units and solar energy to produce hydrogen fuel. Water and electricity are furnished to the unit and the output is hydrogen and oxygen. Three vehicles were converted to utilize the hydrogen produced at the station. The vehicles were all equipped with different types of technologies. The vehicles were used in the day-to-day operation of the Las Vegas Valley Water District and monitoring was performed on efficiency, reliability and maintenance requirements. The research and demonstration utilized for the reconfiguration of these vehicles could lead to new technologies in vehicle development that could make hydrogen-fueled vehicles more cost effective, economical, efficient and more widely used. In order to advance the development of a hydrogen future in Southern Nevada, project partners recognized a need to bring various entities involved in hydrogen development and deployment together as a means of sharing knowledge and eliminating duplication of efforts. A road-mapping session was held in Las Vegas in June 2006. The Nevada State Energy Office, representatives from DOE, DOE contractors and LANL, NETL, NREL were present. Leadership from the National hydrogen Association Board of Directors also attended. As a result of this session, a roadmap for hydrogen development was created. This roadmap has the ability to become a tool for use by other road-mapping efforts in the hydrogen community. It could also become a standard template for other states or even countries to approach planning for a hydrogen

  9. Hydrogen Filling Station

    Energy Technology Data Exchange (ETDEWEB)

    Boehm, Robert F; Sabacky, Bruce; Anderson II, Everett B; Haberman, David; Al-Hassin, Mowafak; He, Xiaoming; Morriseau, Brian

    2010-02-24

    Hydrogen is an environmentally attractive transportation fuel that has the potential to displace fossil fuels. The Freedom CAR and Freedom FUEL initiatives emphasize the importance of hydrogen as a future transportation fuel. Presently, Las Vegas has one hydrogen fueling station powered by natural gas. However, the use of traditional sources of energy to produce hydrogen does not maximize the benefit. The hydrogen fueling station developed under this grant used electrolysis units and solar energy to produce hydrogen fuel. Water and electricity are furnished to the unit and the output is hydrogen and oxygen. Three vehicles were converted to utilize the hydrogen produced at the station. The vehicles were all equipped with different types of technologies. The vehicles were used in the day-to-day operation of the Las Vegas Valley Water District and monitoring was performed on efficiency, reliability and maintenance requirements. The research and demonstration utilized for the reconfiguration of these vehicles could lead to new technologies in vehicle development that could make hydrogen-fueled vehicles more cost effective, economical, efficient and more widely used. In order to advance the development of a hydrogen future in Southern Nevada, project partners recognized a need to bring various entities involved in hydrogen development and deployment together as a means of sharing knowledge and eliminating duplication of efforts. A road-mapping session was held in Las Vegas in June 2006. The Nevada State Energy Office, representatives from DOE, DOE contractors and LANL, NETL, NREL were present. Leadership from the National hydrogen Association Board of Directors also attended. As a result of this session, a roadmap for hydrogen development was created. This roadmap has the ability to become a tool for use by other road-mapping efforts in the hydrogen community. It could also become a standard template for other states or even countries to approach planning for a hydrogen

  10. Cognitive Flexibility in Obsessive Compulsive Disorder

    DEFF Research Database (Denmark)

    Jónsson, Hjalti; Salkovskis, Paul M.

    BT for problems such as OCD requires a level of cognitive flexibility (that is the ability to take a different perspective on ones problems). It could be argued that problems in set shifting (by neuropsychological tests) might underpin problems in this area. Two assessments were used (1: percepti...

  11. Cognitive Flexibility in Obsessive Compulsive Disorder

    DEFF Research Database (Denmark)

    Jónsson, Hjalti; Salkovskis, Paul M.

    BT for problems such as OCD requires a level of cognitive flexibility (that is the ability to take a different perspective on ones problems). It could be argued that problems in set shifting (by neuropsychological tests) might underpin problems in this area. Two assessments were used (1: percepti...

  12. Switch Detection in Preschoolers' Cognitive Flexibility

    Science.gov (United States)

    Chevalier, Nicolas; Wiebe, Sandra A.; Huber, Kristina L.; Espy, Kimberly Andrews

    2011-01-01

    The current study addressed the role of switch detection in cognitive flexibility by testing the effect of transition cues (i.e., cues that directly signal the need to switch or maintain a given task goal) in a cued set-shifting paradigm at 5 years of age. Children performed better, especially on switch trials, when transition cues were combined…

  13. Corrective Action Investigation Plan for Corrective Action Unit 321: Area 22 Weather Station Fuel Storage, Nevada Test Site, Nevada, Revision 0. UPDATED WITH RECORD OF TECHNICAL CHANGE No.1

    Energy Technology Data Exchange (ETDEWEB)

    U.S. DOE/NV

    1999-02-08

    This Corrective Action Investigation Plan (CAIP) has been developed in accordance with the Federal Facility Agreement and Consent Order (FFACO) that was agreed to by the US Department of Energy, Nevada Operations Office (DOE/NV); the State of Nevada Division of Environmental Protection (NDEP); and the US Department of Defense (FFACO, 1996). The CAIP is a document that provides or references all of the specific information for investigation activities associated with Corrective Action Units (CAUs) or Corrective Action Sites (CASs). According to the FFACO (1996), CASs are sites potentially requiring corrective action(s) and may include solid waste management units or individual disposal or release sites. A CAU consists of one or more CASs grouped together based on geography, technical similarity, or agency responsibility for the purpose of determining corrective actions. This CAIP contains the environmental sample collection objectives and the criteria for conducting site investigation activities at the CAU 321 Area 22 Weather Station Fuel Storage, CAS 22-99-05 Fuel Storage Area. For purposes of this discussion, this site will be referred to as either CAU 321 or the Fuel Storage Area. The Fuel Storage Area is located in Area 22 of the Nevada Test Site (NTS). The NTS is approximately 105 kilometers (km) (65 miles [mi]) northwest of Las Vegas, Nevada (DOE/NV, 1996a). The Fuel Storage Area was used to store fuel and other petroleum products necessary for motorized operations at the historic Camp Desert Rock facility which was operational from 1951 to 1958 at the Nevada Test Site, Nevada. The site was dismantled after 1958 (DOE/NV, 1996a).

  14. Gravimetry and GPS observations at Belgrano II station to test ocean tidal models Observaciones gravimètricas y de GPS en la base Belgrano II para probar modelos de mareas oceánicas

    Directory of Open Access Journals (Sweden)

    M. Scheinert

    2007-12-01

    Full Text Available In the framework of a joint Argentine-German project gravimetric time series observations are being carried out at the Argentine Antarctic station Belgrano II. Two gravity meters were installed in the first half of February 2007. The set-up of the gravimeters as well as first results of the ongoing observations are discussed. Additionally, kinematic positions derived from a GPS-station at the Vahsel Bay glacier near Belgrano II can be used to get a first insight into the floating behavior of this glacier. The goal of these observations is to discriminate the effect of ocean tides and to test ocean tidal models. Since ocean tides are an important phenomenon that has to be considered in a variety of geoscientific investigations in polar regions, appropriate corrections have to be applied in the different analyses, e.g. to infer temporal mass variations from satellite data, to investigate ice-shelf dynamics and deformations, or to come up with precise station positions and velocities within a terrestrial reference system. However, the ocean tide models show larger uncertainties in the Antarctic seas and (moreover at areas covered by ice shelves and, therefore, need to be improved. This joint Argentine-German project is a contribution to the International Polar Year 2007/2008 and its project POLENET. After completion of the recordings at Belgrano II by the end of 2007 it is planned to move the equipment to San Mart ín in order to get a second gravimetric time series during the year 2008.En el marco de un proyecto conjunto germano-argentino se están obteniendo registros gravimétricos en la base antártica argentina Belgrano II, mediante dos gravímetros instalados durante la primera mitad de febrero de 2007. Se describen la puesta en marcha del sistema y los primeros resultados obtenidos de las observaciones en curso. Además, posiciones cinemáticas obtenidas mediante una estación GPS emplazada sobre el glaciar de la bahía Vahsel, en un sitio

  15. FLEXIBLE GEIGER COUNTER

    Science.gov (United States)

    Richter, H.G.; Gillespie, A.S. Jr.

    1963-11-12

    A flexible Geiger counter constructed from materials composed of vinyl chloride polymerized with plasticizers or co-polymers is presented. The counter can be made either by attaching short segments of corrugated plastic sleeving together, or by starting with a length of vacuum cleaner hose composed of the above materials. The anode is maintained substantially axial Within the sleeving or hose during tube flexing by means of polystyrene spacer disks or an easily assembled polyethylene flexible cage assembly. The cathode is a wire spiraled on the outside of the counter. The sleeving or hose is fitted with glass end-pieces or any other good insulator to maintain the anode wire taut and to admit a counting gas mixture into the counter. Having the cathode wire on the outside of the counter substantially eliminates the objectional sheath effect of prior counters and permits counting rates up to 300,000 counts per minute. (AEC)

  16. Flexible Metasurface Holograms

    CERN Document Server

    Burch, James; Chen, Xianzhong; Di Falco, Andrea

    2016-01-01

    Metasurface holograms are typically fabricated on rigid substrates. Here we experimentally demonstrate broadband, flexible, conformable, helicity multiplexed metasurface holograms operating in the visible range, offering increased potential for real life out-of-the-lab applications. Two symmetrically distributed holographic images are obtained when circularly polarized light impinges on the reflective-type metasurface positioned on non- planar targets. The two off-axis images with high fidelity are interchangeable by controlling the helicity of incident light. Our metasurface features the arrangement of spatially varying gold nanorods on a flexible, conformable epoxy resist membrane to realize a Pancharatnam- Berry phase profile. These results pave the way to practical applications including polarization manipulation, beam steering, novel lenses, and holographic displays.

  17. Flexible training under threat.

    Science.gov (United States)

    Houghton, Anita; Eaton, Jennifer

    2002-10-01

    As the number of women in medicine and the general demand for a better work-life balance rises, flexible training is an increasingly important mechanism for maintaining the medical workforce. The new pay deal, together with entrenched cultural attitudes, are potential threats. Ways forward include more substantive part-time posts, more part-time opportunities at consultant level, and using positive experiences as a way of tackling attitudes in the less accepting specialties.

  18. Flexible Land Administration

    DEFF Research Database (Denmark)

    Enemark, Stig

    2014-01-01

    Security of tenure is widely considered to be the missing piece of the puzzle when it comes to eradication of poverty. And, as explained in the previous issue of Geoinformatics, the European Union is now placing land rights at the heart of EU development policy. This article presents a way forwar...... in terms of building flexible and "fit-for-purpose" land administration systems in developing countries. This will ensure security of tenure for all and sustainable management of the use of land....

  19. More flexibility for DESY

    CERN Multimedia

    2003-01-01

    In the future, budgeting at DESY will be more efficient. The 16 associated research centers are to be granted a wider margin in matters of finance and human resources. The Budget Committee of the German Bundestag has agreed to abstain from mandatory staff appointments. The current pre-determined "job pyramid" will be replaced by a more flexible mechanism, so that the conclusion of fixed labor contracts can more closely follow the needs of research (1 page).

  20. Industrial Fuel Flexibility Workshop

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2006-09-01

    On September 28, 2006, in Washington, DC, ITP and Booz Allen Hamilton conducted a fuel flexibility workshop with attendance from various stakeholder groups. Workshop participants included representatives from the petrochemical, refining, food and beverage, steel and metals, pulp and paper, cement and glass manufacturing industries; as well as representatives from industrial boiler manufacturers, technology providers, energy and waste service providers, the federal government and national laboratories, and developers and financiers.