WorldWideScience

Sample records for flexible suction caissons

  1. Impedance of flexible suction caissons

    DEFF Research Database (Denmark)

    Liingaard, Morten; Andersen, Lars; Ibsen, Lars Bo

    2007-01-01

    The dynamic response of offshore wind turbines is affected by the properties of the foundation and the subsoil. The aim of this paper is to evaluate the dynamic soil-structure interaction of suction caissons for offshore wind turbines. The investigations include evaluation of the vertical and cou...

  2. Dynamic stiffness of suction caissons

    DEFF Research Database (Denmark)

    Ibsen, Lars Bo; Liingaard, Morten; Andersen, Lars

    The purpose of this report is to evaluate the dynamic soil-structure interaction of suction caissons for offshore wind turbines. The investigation is limited to a determination of the vertical dynamic stiffness of suction caissons. The soil surrounding the foundation is homogenous with linear...... viscoelastic properties. The dynamic stiffness of the suction caisson is expressed by dimensionless frequency-dependent dynamic stiffness coefficients corresponding to the vertical degree of freedom. The dynamic stiffness coefficients for the foundations are evaluated by means of a dynamic three...

  3. Dynamic lateral response of suction caissons

    DEFF Research Database (Denmark)

    Latini, Chiara; Zania, Varvara

    2017-01-01

    Deeper water installations of offshore wind turbines may be supported by jacket structures. This study investigates the dynamic response of suction caissons for jackets by analysing 3D finite element models in the frequency domain. The numerical modelling was firstly validated by analytical...... solutions for pile foundations. Groups of crucial dimensionless parameters related to the soil profile and the foundation geometry are identified and their effects on the response of suction caissons are studied. Static stiffness coefficients are presented in a form of mathematical formulas obtained...... by fitting the numerical results, pertaining foundations with different slenderness ratios and embedded in different soil profiles. Sensitivity of the dynamic impedances of suction caissons on the skirt length was showed in this study. Moreover, the results for the suction caissons indicated that the overall...

  4. Suction caissons subjected to monotonic combined loading

    DEFF Research Database (Denmark)

    Penzes, P.; Jensen, M.R.; Zania, Varvara

    2016-01-01

    Suction caissons are being increasingly used as offshore foundation solutions in shallow and intermediate water depths. The convenient installation method through the application of suction has rendered this type of foundation as an attractive alternative to the more traditional monopile foundation...... for offshore wind turbines. The combined loading imposed typically to a suction caisson has led to the estimation of their bearing capacity by means of 3D failure envelopes. This study aims to analyse the behaviour of suction caissons for offshore wind turbines subjected to combined loading. Finite element...

  5. Suction caissons subjected to monotonic combined loading

    OpenAIRE

    Penzes, P.; Jensen, M.R.; Zania, Varvara

    2016-01-01

    Suction caissons are being increasingly used as offshore foundation solutions in shallow and intermediate water depths. The convenient installation method through the application of suction has rendered this type of foundation as an attractive alternative to the more traditional monopile foundation for offshore wind turbines. The combined loading imposed typically to a suction caisson has led to the estimation of their bearing capacity by means of 3D failure envelopes. This study aims to anal...

  6. Dynamic Behaviour of Suction Caissons

    DEFF Research Database (Denmark)

    Liingaard, Morten

    to the excitation frequencies of the rotor system, it is of outmost importance to be able to evaluate the resonance frequencies of the wind turbine structure accurately as the wind turbines increase in size. In order to achieve reliable responses of the wind turbine structure during working loads it is necessary...... in a composite structure-foundation system. The work has been focused on one particular foundation type; the suction caisson. The frequency dependent stiffness (impedance) of the suction caisson has been investigated by means of a three-dimensional coupled Boundary Element/Finite Element model, where the soil...

  7. Dynamic stiffness of horizontally vibrating suction caissons

    DEFF Research Database (Denmark)

    Latini, Chiara; Zania, Varvara; Cisternino, Michele

    2016-01-01

    The promising potential for offshore wind market is on developing wind farms in deeper waters with bigger turbines. In deeper waters the design foundation configuration may consist of jacket structures supported by floating piles or by suction caissons. Taking the soil-structure interaction effects...... into consideration requires the prior estimation of the dynamic impedances of the foundation. Even though numerous studies exist for piles, only limited number of publications can be found for suction caissons subjected to dynamic loads. Therefore, the purpose of this study is to examine the dynamic response...... of this type of foundation using the finite element method (FEM) to account for the interaction with the soil. 3D numerical models for both the soil and the suction caisson are formulated in a frequency domain. The response of the soil surrounding the foundation is considered linear viscoelastic...

  8. Dynamic stiffness of suction caissons

    DEFF Research Database (Denmark)

    Ibsen, Lars Bo; Liingaard, Morten; Andersen, Lars

    This report concerns the dynamic soil-structure interaction of steel suction caissons applied as foundations for offshore wind turbines. An emphasis is put on torsional vibrations and coupled sliding/rocking motion, and the influence of the foundation geometry and the properties of the surrounding...... soil is examined. The soil is simplified as a homogenous linear viscoelastic material and the dynamic stiffness of the suction caisson is expressed in terms of dimensionless frequency-dependent coefficients corresponding to the different degrees of freedom. The dynamic stiffness coefficients...... for the skirted foundation are evaluated by means of a three-dimensional coupled boundary element/finite element model. Comparisons with known analytical and numerical solutions indicate that the static and dynamic behaviour of the foundation are predicted accurately with the applied model. The analysis has been...

  9. Dynamic stiffness of suction caissons - vertical vibrations

    Energy Technology Data Exchange (ETDEWEB)

    Ibsen, Lars Bo; Liingaard, M.; Andersen, Lars

    2006-12-15

    The dynamic response of offshore wind turbines are affected by the properties of the foundation and the subsoil. The purpose of this report is to evaluate the dynamic soil-structure interaction of suction caissons for offshore wind turbines. The investigation is limited to a determination of the vertical dynamic stiffness of suction caissons. The soil surrounding the foundation is homogenous with linear viscoelastic properties. The dynamic stiffness of the suction caisson is expressed by dimensionless frequency-dependent dynamic stiffness coefficients corresponding to the vertical degree of freedom. The dynamic stiffness coefficients for the foundations are evaluated by means of a dynamic three-dimensional coupled Boundary Element/Finite Element model. Comparisons are made with known analytical and numerical solutions in order to evaluate the static and dynamic behaviour of the Boundary Element/Finite Element model. The vertical frequency dependent stiffness has been determined for different combinations of the skirt length, Poisson's ratio and the ratio between soil stiffness and skirt stiffness. Finally the dynamic behaviour at high frequencies is investigated. (au)

  10. Numerical Buckling Analysis of Large Suction Caissons for Wind Turbines on Deep Water

    DEFF Research Database (Denmark)

    Madsen, Søren; Andersen, Lars Vabbersgaard; Ibsen, Lars Bo

    2013-01-01

    Using large suction caissons for offshore wind turbines is an upcoming cost-effective technology also referred to as bucket foundations. During operation, the monopod bucket foundation is loaded by a large overturning moment from the wind turbine and the wave loads. However, during installation...... the suction caisson is loaded by external pressure (internal suction) due to evacuation of water inside the bucket and vertical forces due to gravity. The risk of structural buckling during installation of large-diameter suction caissons is addressed using numerical methods. Initial imperfect geometries...

  11. The application of suction caisson technology to offshore wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-09-15

    A mathematical model describing the behaviour of caisson foundations for offshore wind turbines has been developed. The model has been verified and calibrated through laboratory and field work. Simultaneously, conceptual designs of wind turbine foundations incorporating suction caissons were studied using the same model. It was concluded that much of the seabed around Britain is well suited to the use of caissons and monopod and quadropod structures are superior to tripods. Although suction caissons are vulnerable to scour, rock dumping can largely eliminate this potential problem. The next phase will be to install a fully instrumented full-scale prototype to monitor the effects of wind and waves. The main contractor was SLP Engineering Limited and about 75 per cent of the funding came from the DTI.

  12. Dynamic behaviour of suction caissons

    Energy Technology Data Exchange (ETDEWEB)

    Liingaard, M.

    2006-12-15

    Offshore wind energy is a promising source of energy in the near future, and is rapidly becoming competitive with other power generating technologies. The continuous improvement in wind turbine technology means that the wind turbines have increased tremendously in both size and performance during the last 25 years. In order to reduce the costs, the overall weight of the wind turbine components is minimized, which means that the wind turbine structures become more flexible and thus more sensitive to dynamic excitation. Since the first resonance frequency of the modern offshore wind turbines is close to the excitation frequencies of the rotor system, it is of outmost importance to be able to evaluate the resonance frequencies of the wind turbine structure accurately as the wind turbines increase in size. In order to achieve reliable responses of the wind turbine structure during working loads it is necessary to account for the possibilities of dynamic effects of the soil-structure interaction. The aim of this thesis is to evaluate the dynamic soil-structure interaction of foundations for offshore wind turbines, with the intention that the dynamic properties of the foundation can be properly included in a composite structure-foundation system. The work has been focused on one particular foundation type; the suction caisson. The frequency dependent stiffness (impedance) of the suction caisson has been investigated by means of a three-dimensional coupled Boundary Element/Finite Element model, where the soil is simplified as a homogenous linear viscoelastic material. The dynamic stiffness of the suction caisson is expressed in terms of dimensionless frequencydependent coefficients corresponding to the different degrees of freedom. Comparisons with known analytical and numerical solutions indicate that the static and dynamic behaviour of the foundation are predicted accurately with the applied model. The analysis has been carried out for different combinations of the

  13. Response of skirted suction caissons to monotonic lateral loading in saturated medium sand

    Science.gov (United States)

    Li, Da-yong; Zhang, Yu-kun; Feng, Ling-yun; Guo, Yan-xue

    2014-08-01

    Monotonic lateral load model tests were carried out on steel skirted suction caissons embedded in the saturated medium sand to study the bearing capacity. A three-dimensional continuum finite element model was developed with Z_SOIL software. The numerical model was calibrated against experimental results. Soil deformation and earth pressures on skirted caissons were investigated by using the finite element model to extend the model tests. It shows that the "skirted" structure can significantly increase the lateral capacity and limit the deflection, especially suitable for offshore wind turbines, compared with regular suction caissons without the "skirted" at the same load level. In addition, appropriate determination of rotation centers plays a crucial role in calculating the lateral capacity by using the analytical method. It was also found that the rotation center is related to dimensions of skirted suction caissons and loading process, i.e. the rotation center moves upwards with the increase of the "skirted" width and length; moreover, the rotation center moves downwards with the increase of loading and keeps constant when all the sand along the caisson's wall yields. It is so complex that we cannot simply determine its position like the regular suction caisson commonly with a specified position to the length ratio of the caisson.

  14. Present knowledge about Laboratory Testing of Axial Loading on Suction Caissons

    DEFF Research Database (Denmark)

    Manzotti, E.; Vaitkunaite, Evelina; Ibsen, Lars Bo

    Offshore wind turbines are increasing in both efficiency and size. More economical foundations for such light structures are under investigation, and suction caisson was shown to be particularly suitable for this purpose. In multi-pod foundation configuration, the overturning moment given by loads...... on the structure is resisted by push-pull loads on the vertical axis of each suction caisson. Relevant works where this situation is examined by means of laboratory testing are summarized in this article, then different conclusions are followed by discussion and comparison. In the initial theoretical section...

  15. Alternative Shape of Suction Caisson to Reduce Risk of Buckling under high Pressure

    DEFF Research Database (Denmark)

    Madsen, Søren; Andersen, Lars Vabbersgaard; Ibsen, Lars Bo

    2013-01-01

    Using large suction caissons for offshore wind turbines is an upcoming technology also referred to as bucket foundations. During operation the bucket foundation is loaded by a large overturning moment from the wind turbine and the wave loads. However, during installation the bucket is loaded...... cylindrical monopod foundation made of steel. In this paper, an alternative design/shape of the suction caisson, having a smaller risk of buckling under high pressure is presented. The risk of structural buckling is addressed using numerical methods to determine the buckling pressures of the re...

  16. Dynamic stiffness of suction caissons - torsion, sliding and rocking

    Energy Technology Data Exchange (ETDEWEB)

    Ibsen, Lars Bo; Liingaard, M.; Andersen, Lars

    2006-12-15

    This report concerns the dynamic soil-structure interaction of steel suction caissons applied as foundations for offshore wind turbines. An emphasis is put on torsional vibrations and coupled sliding/rocking motion, and the influence of the foundation geometry and the properties of the surrounding soil is examined. The soil is simplified as a homogenous linear viscoelastic material and the dynamic stiffness of the suction caisson is expressed in terms of dimensionless frequency-dependent coefficients corresponding to the different degrees of freedom. The dynamic stiffness coefficients for the skirted foundation are evaluated by means of a three-dimensional coupled boundary element/finite element model. Comparisons with known analytical and numerical solutions indicate that the static and dynamic behaviour of the foundation are predicted accurately with the applied model. The analysis has been carried out for different combinations of the skirt length and the Poisson's ratio of the subsoil. Finally, the high-frequency impedance has been determined for future use in lumped-parameter models of wind turbine foundations in aero-elastic codes. (au)

  17. Long term effects of cyclic loading on suction caisson foundations in sand

    NARCIS (Netherlands)

    Lupea, C.; Thijssen, R.; Van Tol, A.F.

    2014-01-01

    Offshore wind turbine projects have been characterised by an increase in costs, sizes and distances from shore, EWEA 2012 This created a need of investigating the adequacy of alternative and more fìnancially attractive foundation types such as suction caissons. Within a multi-footing configuration,

  18. Installation process of suction anchors in Gulf of Guinea clay : Centrifuge modelling

    OpenAIRE

    THOREL, Luc; GARNIER, Jacques; RAULT, Gérard; DENDANI, Hédi; COLLIAT, JL

    2010-01-01

    The preparation process of a deepwater Gulf of Guinea clay for modelling of 24 m long suction anchors at a scale of 1/100 in the LCPC centrifuge, the clay characteristics and the installation phase (self-weight and suction) are presented. Two types of caissons have been tested in each tub : one with stiffeners and the other without stiffener. The embedment ratio is close to the suction caisson's slenderness of 3. An analysis of the forces of suction and soil friction shows, as expected, hi...

  19. H-M bearing capacity of a modified suction caisson determined by using load-/displacement-controlled methods

    Science.gov (United States)

    Zhang, Yu-kun; Gao, Yu-feng; Li, Da-yong; Mahfouz, Ali H.

    2016-12-01

    This paper presents a series of monotonically combined lateral loading tests to investigate the bearing capacity of the MSCs (modified suction caissons) in the saturated marine fine sand. The lateral loads were applied under load- and displacement-controlled methods at the loading eccentricity ratios of 1.5, 2.0 and 2.5. Results show that, in the displacement-controlled test, the deflection-softening behavior of load-deflection curves for MSCs was observed, and the softening degree of the load-deflection response increased with the increasing external skirt length or the decreasing loading eccentricity. It was also found that the rotation center of the MSC at failure determined by the load-controlled method is slightly lower than that by the displacement-controlled method. The calculated MSC capacity based on the rotation center position in serviceability limit state is relatively conservative, compared with the calculated capacity based on the rotation center position in the ultimate limit state. In the limit state, the passive earth pressures opposite the loading direction under load- and displacement-controlled methods decrease by 46% and 74% corresponding to peak values, respectively; however, the passive earth pressures in the loading direction at failure only decrease by approximately 3% and 7%, compared with their peak values.

  20. 29 CFR 1926.801 - Caissons.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Caissons. 1926.801 Section 1926.801 Labor Regulations...) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Underground Construction, Caissons, Cofferdams and Compressed Air § 1926.801 Caissons. (a) Wherever, in caisson work in which compressed air is used, and the...

  1. Structural damage monitoring of harbor caissons with interlocking condition

    Energy Technology Data Exchange (ETDEWEB)

    Huynh, Thanh Canh; Lee, So Young; Nauyen, Khac Duy; Kim, Jeong Tae [Pukyong National Univ., Busan (Korea, Republic of)

    2012-12-15

    The objective of this study is to monitor the health status of harbor caissons which have potential foundation damage. To obtain the objective, the following approaches are performed. Firstly, a structural damage monitoring(SDM) method is designed for interlocked multiple caisson structures. The SDM method utilizes the change in modal strain energy to monitor the foundation damage in a target caisson unit. Secondly, a finite element model of a caisson system which consists of three caisson units is established to verify the feasibility of the proposed method. In the finite element simulation, the caisson units are constrained each other by shear key connections. The health status of the caisson system against various levels of foundation damage is monitored by measuring relative modal displacements between the adjacent caissons.

  2. Structural damage monitoring of harbor caissons with interlocking condition

    International Nuclear Information System (INIS)

    Huynh, Thanh Canh; Lee, So Young; Nauyen, Khac Duy; Kim, Jeong Tae

    2012-01-01

    The objective of this study is to monitor the health status of harbor caissons which have potential foundation damage. To obtain the objective, the following approaches are performed. Firstly, a structural damage monitoring(SDM) method is designed for interlocked multiple caisson structures. The SDM method utilizes the change in modal strain energy to monitor the foundation damage in a target caisson unit. Secondly, a finite element model of a caisson system which consists of three caisson units is established to verify the feasibility of the proposed method. In the finite element simulation, the caisson units are constrained each other by shear key connections. The health status of the caisson system against various levels of foundation damage is monitored by measuring relative modal displacements between the adjacent caissons

  3. Expected sliding distance of vertical slit caisson breakwater

    Science.gov (United States)

    Kim, Dong Hyawn

    2017-06-01

    Evaluating the expected sliding distance of a vertical slit caisson breakwater is proposed. Time history for the wave load to a vertical slit caisson is made. It consists of two impulsive wave pressures followed by a smooth sinusoidal pressure. In the numerical analysis, the sliding distance for an attack of single wave was shown and the expected sliding distance during 50 years was also presented. Those results were compared with a vertical front caisson breakwater without slit. It was concluded that the sliding distance of a vertical slit caisson may be over-estimated if the wave pressure on the caisson is evaluated without considering vertical slit.

  4. Experimental Investigation on Caisson Breakwater Sliding

    DEFF Research Database (Denmark)

    Ruol, Piero; Martin, Paolo; Andersen, Thomas Lykke

    2014-01-01

    This note presents wave flume experiments, carried out at Aalborg University, measuring the horizontal sliding distance of a vertical breakwater in 1:40 scale. Horizontal and uplift wave induced pressures were accurately measured simultaneously with the caisson movements. Caissons of different...

  5. Study on the breakwater caisson as oscillating water column facility

    Science.gov (United States)

    Huang, Yan; Shi, Hongda; Liu, Defu; Liu, Zhen

    2010-09-01

    The Oscillating Water Column (OWC) wave energy convertor with the advantage of its simple geometrical construction and excellent stability is widely employed. Recently, perforated breakwaters have been often used as they can effectively reduce the wave reflection from and wave forces acting on the structures. Considering the similarity between the compartment of perforated caisson and the air chamber of OWC wave energy convertor, a new perforated caisson of breakwater is designed in this paper. The ordinary caisson is modified by installing facilities similar to the air chamber of OWC converter, but here they are utilized to dissipate the wave energy inside the caisson. Such an arrangement improves the stability of the caisson and reduces the construction cost by using the compartment of perforated caisson like using an air chamber. This innovation has both academic significance and important engineering value. For a new type of caisson, reliability analysis of the structure is necessary. Linear potential flow theory is applied to calculate the horizontal wave force acting on the caisson. The calculated results are compared with experimental data, showing the feasibility of the method. The Importance Sampling Procedure (ISP) is used to analyse the reliability of this caisson breakwater.

  6. D Digital Simulation of Minnan Temple Architecture CAISSON'S Craft Techniques

    Science.gov (United States)

    Lin, Y. C.; Wu, T. C.; Hsu, M. F.

    2013-07-01

    Caisson is one of the important representations of the Minnan (southern Fujian) temple architecture craft techniques and decorative aesthetics. The special component design and group building method present the architectural thinking and personal characteristics of great carpenters of Minnan temple architecture. In late Qing Dynasty, the appearance and style of caissons of famous temples in Taiwan apparently presented the building techniques of the great carpenters. However, as the years went by, the caisson design and craft techniques were not fully inherited, which has been a great loss of cultural assets. Accordingly, with the caisson of Fulong temple, a work by the well-known great carpenter in Tainan as an example, this study obtained the thinking principles of the original design and the design method at initial period of construction through interview records and the step of redrawing the "Tng-Ko" (traditional design, stakeout and construction tool). We obtained the 3D point cloud model of the caisson of Fulong temple using 3D laser scanning technology, and established the 3D digital model of each component of the caisson. Based on the caisson component procedure obtained from interview records, this study conducted the digital simulation of the caisson component to completely recode and present the caisson design, construction and completion procedure. This model of preserving the craft techniques for Minnan temple caisson by using digital technology makes specific contribution to the heritage of the craft techniques while providing an important reference for the digital preservation of human cultural assets.

  7. Development of myopia as a hazard for workers in pneumatic caissons

    Science.gov (United States)

    Onoo, A; Kiyosawa, M; Takase, H; Mano, Y

    2002-01-01

    Background/aim: Pneumatic caisson engineering has been developed for large civil engineering constructions. Because of complaints of blurred vision by personnel working in pneumatic caissons, the development of myopia was suspected. The aim of this study was to determine the cause of the blurred vision and the mechanism underlying the changes. Methods: 12 caisson workers underwent a complete ophthalmological examination after completing up to 11 weeks of work (4 days/week) in a pneumatic caisson. Six months later, nine of the workers were examined again. Results: Nine subjects were myopic at the initial examination, and seven of these were considered to have developed the myopia after starting to work in the pneumatic caisson. Six months after completion of the work, the mean refractive change was significantly towards hyperopia. Conclusions: The blurred vision in pneumatic caisson workers was in all likelihood due to the development of myopia. The refractive shift towards hyperopia after completion of work in the pneumatic caisson supports this and demonstrates that the changes were temporary. The myopia is similar to the myopia seen in patients treated by hyperbaric oxygen. Careful monitoring of the refraction of caisson workers should be performed for industrial health control. PMID:12386088

  8. 3D DIGITAL SIMULATION OF MINNAN TEMPLE ARCHITECTURE CAISSON'S CRAFT TECHNIQUES

    Directory of Open Access Journals (Sweden)

    Y. C. Lin

    2013-07-01

    Full Text Available Caisson is one of the important representations of the Minnan (southern Fujian temple architecture craft techniques and decorative aesthetics. The special component design and group building method present the architectural thinking and personal characteristics of great carpenters of Minnan temple architecture. In late Qing Dynasty, the appearance and style of caissons of famous temples in Taiwan apparently presented the building techniques of the great carpenters. However, as the years went by, the caisson design and craft techniques were not fully inherited, which has been a great loss of cultural assets. Accordingly, with the caisson of Fulong temple, a work by the well-known great carpenter in Tainan as an example, this study obtained the thinking principles of the original design and the design method at initial period of construction through interview records and the step of redrawing the "Tng-Ko" (traditional design, stakeout and construction tool. We obtained the 3D point cloud model of the caisson of Fulong temple using 3D laser scanning technology, and established the 3D digital model of each component of the caisson. Based on the caisson component procedure obtained from interview records, this study conducted the digital simulation of the caisson component to completely recode and present the caisson design, construction and completion procedure. This model of preserving the craft techniques for Minnan temple caisson by using digital technology makes specific contribution to the heritage of the craft techniques while providing an important reference for the digital preservation of human cultural assets.

  9. Three-dimensional numerical simulation of wave interaction with perforated quasi-ellipse caisson

    Directory of Open Access Journals (Sweden)

    Yong-xue Wang

    2011-03-01

    Full Text Available The finite difference method and the volume of fluid (VOF method were used to develop a three-dimensional numerical model to study wave interaction with a perforated caisson. The partial cell method was adopted to solve this type of problem for the first time. The validity of the present model, with and without the presence of caisson structures, was examined by comparing the model results with experimental data. Then, the numerical model was used to investigate the effects of various wave and structure parameters on the wave force and wave runup of the perforated quasi-ellipse caisson. Compared with the solid quasi-ellipse caisson, the wave force on the perforated quasi-ellipse caisson is significantly reduced with increasing porosity of the perforated quasi-ellipse caisson. Furthermore, the perforated quasi-ellipse caisson can also reduce the wave runup, and it tends to decrease with the increase of the porosity of the perforated quasi-ellipse caisson and the relative wave height.

  10. An experimental study of irregular wave forces on multiple quasi-ellipse caissons

    Science.gov (United States)

    Ren, Xiaozhong; Zhang, Peng; Ma, Yuxiang; Meng, Yufan

    2014-09-01

    An experimental investigation of irregular wave forces on quasi-ellipse caisson structures is presented. Irregular waves were generated based on the Jonswap spectrum with two significant wave heights, and the spectrum peak periods range from 1.19 s to 1.81 s. Incident wave directions relative to the centre line of the multiple caissons are from 0° to 22.5°. The spacing between caissons ranges from 2 to 3 times that of the width of the caisson. The effects of these parameters on the wave forces of both the perforated and non-perforated caissons were compared and analyzed. It was found that the perforated caisson can reduce wave forces, especially in the transverse direction. Furthermore, the relative interval and incident wave direction have significant effects on the wave forces in the case of multiple caissons.

  11. New Method of Sinking Caisson Tunnel in Soft Soil

    OpenAIRE

    Bame, Abda Berisso

    2013-01-01

    Sinking a caisson tunnel in soft soil is new idea and this new concept could be an alternative method of tunneling in soft soil. The aim of this study is to evaluate geotechnical feasibility of sinking the caisson tunnel to the desired depth at the selected soil profile along tunnel alignment. This caisson tunneling method is proposed to reduce the use of temporary works such as propping of sheet pile walls and increase the ease and speed of construction. Besides, it reduces the disturbance o...

  12. Vibration-based structural health monitoring of harbor caisson structure

    Science.gov (United States)

    Lee, So-Young; Lee, So-Ra; Kim, Jeong-Tae

    2011-04-01

    This study presents vibration-based structural health monitoring method in foundation-structure interface of harbor caisson structure. In order to achieve the objective, the following approaches are implemented. Firstly, vibration-based response analysis method is selected and structural health monitoring (SHM) technique is designed for harbor caisson structure. Secondly, the performance of designed SHM technique for harbor structure is examined by FE analysis. Finally, the applicability of designed SHM technique for harbor structure is evaluated by dynamic tests on a lab-scaled caisson structure.

  13. Caisson disease during the construction of the Eads and Brooklyn Bridges: A review.

    Science.gov (United States)

    Butler, W P

    2004-01-01

    The Eads Bridge (St. Louis) and the Brooklyn Bridge (New York City) were testing grounds for caisson construction. These caissons were enormous compressed air boxes used to build riverine piers and abutments anchoring the bridges. Caisson meant faster and cheaper construction, but there was a hidden cost---caisson disease (decompression sickness). Within caissons, workers labored at pressures as high as 55 psig and caisson disease was common. This discourse is a brief history of the caisson, a brief discussion of the illness as viewed in the mid 1800's, and an abbreviated history of the Eads and Brooklyn Bridges. It also provides a detailed description and evaluation of the observations, countermeasures, and recommendations of Dr. Alphonse Jaminet, the Eads Bridge physician, and Dr. Andrew Smith, the Brooklyn Bridge physician, who published reports of their experience in 1871 and 1873, respectively. These and other primary sources permit a detailed examination of early caisson disease and Jaminet's and Smith's thinking also serve as good examples from which to study and learn.

  14. Hydraulic Structures : Caissons

    NARCIS (Netherlands)

    Voorendt, M.Z.; Molenaar, W.F.; Bezuyen, K.G.

    These lecture notes on caissons are part of the study material belonging to the course 'Hydraulic Structures 1' (code CTB3355), part of the Bachelor of Science education and the Hydraulic Engineering track of the Master of Science education for civil engineering students at Delft University of

  15. Wireless vibration-based SHM of caisson-type breakwater under foundation damage

    Science.gov (United States)

    Lee, So-Young; Nguyen, Khac-Duy; Kim, Jeong-Tae; Yi, Jin-Hak

    2012-04-01

    This paper presents a vibration-based structural health monitoring (SHM) technique using a high sensitive wireless sensor node for caisson-type breakwater. To achieve the objective, the following approaches are implemented. Firstly, vibration-based SHM method is selected for caisson-type breakwater. The feasibility of the vibration-based SHM method is examined for the caisson structure by FE analysis. Foundation loss damage is considered as the damage of caisson-type breakwater. Secondly, a wireless SHM system with a high sensitive wireless sensor node is designed. The sensor node is built on an imote2 platform. The vibration-based SHM method is embedded on the sensor node. Finally, the performance of the wireless SHM technique is estimated from experimental tests on a lab-scaled caisson. The vibration responses and damage monitoring results are compared with the proposed wireless system and conventional wired system.

  16. Tritium behavior in the Caisson, a simulated fusion reactor room

    International Nuclear Information System (INIS)

    Hayashi, Takumi; Kobayashi, Kazuhiro; Iwai, Yasunori; Yamada, Masayuki; Suzuki, Takumi; O'hira, Shigeru; Nakamura, Hirofumi; Shu, Weimin; Yamanishi, Toshihiko; Kawamura, Yoshinori; Isobe, Kanetsugu; Konishi, Satoshi; Nishi, Masataka

    2000-01-01

    In order to confirm tritium confinement ability in the deuterium-tritium (DT) fusion reactor, intentional tritium release experiments have been started in a specially fabricated test stand called 'Caisson', at Tritium Process Laboratory in Japan Atomic Energy Research Institute. The Caisson is a stainless steel leak-tight vessel of 12 m 3 , simulating a reactor room or a tritium handling room. In the first stage experiments, about 260 MBq of pure tritium was put into the Caisson under simulated constant ventilation of four times air exchanges per h. The tritium mixing and migration in the Caisson was investigated with tritium contamination measurement and detritiation behavior measurement. The experimental tritium migration and removal behavior was almost perfectly reproduced and could almost be simulated by a three-dimensional flow analysis code

  17. Numerical Simulations for Nonlinear Waves Interaction with Multiple Perforated Quasi-Ellipse Caissons

    Directory of Open Access Journals (Sweden)

    Xiaozhong Ren

    2015-01-01

    Full Text Available A three-dimensional numerical flume is developed to study cnoidal wave interaction with multiple arranged perforated quasi-ellipse caissons. The continuity equation and the Navier-Stokes equations are used as the governing equation, and the VOF method is adopted to capture the free surface elevation. The equations are discretized on staggered cells and then solved using a finite difference method. The generation and propagation of cnoidal waves in the numerical flume are tested first. And the ability of the present model to simulate interactions between waves and structures is verified by known experimental results. Then cnoidal waves with varying incident wave height and period are generated and interact with multiple quasi-ellipse caissons with and without perforation. It is found that the perforation plays an effective role in reducing wave runup/rundown and wave forces on the caissons. The wave forces on caissons reduce with the decreasing incident wave period. The influence of the transverse distance of multiple caissons on wave forces is also investigated. A closer transverse distance between caissons can produce larger wave forces. But when relative adjacent distance L/D (L is the transverse distance and D is the width of the quasi-ellipse caisson is larger than 3, the effect of adjacent distance is limited.

  18. Caissons voor het dichten van dijken in Zeeland 1953

    NARCIS (Netherlands)

    Verhagen, H.J.

    1953-01-01

    Foto's van caissons voor het dichten van dijken in Zeeland in 1953. Geleverd werden 493 caissons en 203 manchetten door een combinatie van: • N.V. Amsterdamsche Ballast maatschappij, Amsterdam • Christiani en Nielsen N.V., ’s Gravenhage • N.V. van Hattum en Blankevoort, Beverwijk • Hollandsche Beton

  19. Electrokinetic Treatment for Model Caissons with Increasing Dimensions

    Directory of Open Access Journals (Sweden)

    Eltayeb Mohamedelhassan

    2012-01-01

    Full Text Available Electrokinetic treatment has been known in geotechnical engineering for over six decades, yet, the technique is rarely used. This stems from the absence of design guidelines and specifications for electrokinetic treatment systems. An important issue that need to be investigated and understood in order to devise guidelines from experimental results is the effect of the foundation element size on the outcome of the treatment. Also important is determining the optimum distance between the electrodes and estimating the energy consumption prior to treatment. This experimental study is a preliminary step in understanding some of the issues critical for the guidelines and specifications. Four model caissons with surface areas between 16000 and 128000 mm2 were embedded in soft clayey soil under water and treated for 168 hr with a dc voltage of 6 V. From the results, a distance between the anode (model caisson and the cathode equal 0.25 times the outside diameter of the model caisson was identified as optimum. Relationships between the surface area and axial capacity of the model caisson and the surface area and energy consumption were presented. The equations can be used to preliminary estimate the load capacity and the energy consumption for full-scale applications.

  20. Design of Vertical Wall Caisson Breakwaters using Partial Safety Factors

    DEFF Research Database (Denmark)

    Burcharth, H. F.; Sørensen, John Dalsgaard

    1999-01-01

    The paper presents a new system for implementation of target reliability in caisson breakwater designs by means of partial safety factors. The development of the system is explained, and tables of partial safety factors are presented for important overall stability failure modes related to caisson...

  1. Analysis of Oblique Wave Interaction with a Comb-Type Caisson Breakwater

    Science.gov (United States)

    Wang, Xinyu; Liu, Yong; Liang, Bingchen

    2018-04-01

    This study develops an analytical solution for oblique wave interaction with a comb-type caisson breakwater based on linear potential theory. The fluid domain is divided into inner and outer regions according to the geometrical shape of breakwater. By using periodic boundary condition and separation of variables, series solutions of velocity potentials in inner and outer regions are developed. Unknown expansion coefficients in series solutions are determined by matching velocity and pressure of continuous conditions on the interface between two regions. Then, hydrodynamic quantities involving reflection coefficients and wave forces acting on breakwater are estimated. Analytical solution is validated by a multi-domain boundary element method solution for the present problem. Diffusion reflection due to periodic variations in breakwater shape and corresponding surface elevations around the breakwater are analyzed. Numerical examples are also presented to examine effects of caisson parameters on total wave forces acting on caissons and total wave forces acting on side plates. Compared with a traditional vertical wall breakwater, the wave force acting on a suitably designed comb-type caisson breakwater can be significantly reduced. This study can give a better understanding of the hydrodynamic performance of comb-type caisson breakwaters.

  2. Design and execution of double slits type straight caisson at exclusive harbors of Ooma nuclear power plant

    International Nuclear Information System (INIS)

    Tsukamoto, Kunihiro; Yamamoto, Morikuni; Naruoka, Masayoshi; Matsubara, Takayuki

    2004-01-01

    Ooma nuclear power plant is going to build the exclusive harbors, of which west breakwater is a double slits type straight caisson bank (double slits caisson). It contains double transmission walls and retarding rooms, which show large effect of breaker, because the reflected wave height of short-period component is decreased in the rear retarding room and one of long-period component decreased in both retarding rooms. Accordingly, it is seemed to be proved larger effect of breaker than one slit type caisson. Outline of harbors construction, adoption of double slits caisson, design of caisson, construction of caisson and installation are stated. The effect of breaker of double slits caisson is shown. (S.Y.)

  3. Numerical method for wave forces acting on partially perforated caisson

    Science.gov (United States)

    Jiang, Feng; Tang, Xiao-cheng; Jin, Zhao; Zhang, Li; Chen, Hong-zhou

    2015-04-01

    The perforated caisson is widely applied to practical engineering because of its great advantages in effectively wave energy consumption and cost reduction. The attentions of many scientists were paid to the fluid-structure interaction between wave and perforated caisson studies, but until now, most concerns have been put on theoretical analysis and experimental model set up. In this paper, interaction between the wave and the partial perforated caisson in a 2D numerical wave flume is investigated by means of the renewed SPH algorithm, and the mathematical equations are in the form of SPH numerical approximation based on Navier-Stokes equations. The validity of the SPH mathematical method is examined and the simulated results are compared with the results of theoretical models, meanwhile the complex hydrodynamic characteristics when the water particles flow in or out of a wave absorbing chamber are analyzed and the wave pressure distribution of the perforated caisson is also addressed here. The relationship between the ratio of total horizontal force acting on caisson under regular waves and its influence factors is examined. The data show that the numerical calculation of the ratio of total horizontal force meets the empirical regression equation very well. The simulations of SPH about the wave nonlinearity and breaking are briefly depicted in the paper, suggesting that the advantages and great potentiality of the SPH method is significant compared with traditional methods.

  4. Stochastic analysis of transport of conservative solutes in caisson experiments

    International Nuclear Information System (INIS)

    Dagan, G.

    1995-01-01

    The Los Alamos National Laboratory has conducted in the past a series of experiments of transport of conservative and reactive solutes. The experimental setup and the experimental results are presented in a series of reports. The main aim of the experiments was to validate models of transport of solutes in unsaturated flow at the caisson intermediate scale, which is much larger than the one pertaining to laboratory columns. First attempts to analyze the experimental results were by one-dimensional convective-dispersion models. These models could not explain the observed solute breakthrough curves and particularly the large solute dispersion in the caisson effluent Since there were some question marks about the uniformity of water distribution at the caisson top, the transport experiments were repeated under conditions of saturated flow. In these experiments constant heads were applied at the top and the bottom of the caisson and the number of concentration monitoring stations was quadrupled. The analysis of the measurements by the same one-dimensional model indicated clearly that the fitted dispersivity is much larger than the pore-sole dispersivity and that it grows with the distance in an approximately linear fashion. This led to the conclusion, raised before, that transport in the caisson is dominated by heterogeneity effects, i.e. by spatial variability of the material Such effects cannot be captured by traditional one-dimensional models. In order to account for the effect of heterogeneity, the saturated flow experiments have been analyzed by using stochastic transport modeling. The apparent linear growth of dispersivity with distance suggested that the system behaves like a stratified one. Consequently, the model of Dagan and Bresier has been adopted in order to interpret concentration measurements. In this simple model the caisson is viewed as a bundle of columns of different permeabilities, which are characterized by a p.d.f. (probability denasity function)

  5. EFFECTS OF THE BACK-FILLING TO THE STABILITY OF A CAISSON

    Science.gov (United States)

    Kikuchi, Yoshiaki; Shinsha, Hiroshi; Kawamura, Kensuke; Eguchi, Shinya

    The back-filling improves the stability of a caisson used for breakwater against wave force. But, the extent of the improvement of the stability is affected by the interaction among the back-filling and the caisson and the foundation. A series of the model loading experiments was carried out to clarify the effects of the interaction to the stability. In this series of experiments, horizontal static load was applied to the model caisson having back-filling. Sliding failure surface was estimated from the deformation of rubble mound and back-filling. Passive earth pressure by back-filling calculated by wedge theory was compared with the experimental results. New stability evaluation method considering circular arc failure mode was developed and evaluated its validity. Followings are main conclusions in this research; 1) Increment of stability of a caisson against wave force can be estimated from wedge theory. 2) Both sliding and bearing capacity stability were considered in one time using newly developed evaluation method considering circular arc failure mode.

  6. Numerical simulation of nonlinear wave force on a quasi-ellipse caisson

    Science.gov (United States)

    Wang, Yongxue; Ren, Xiaozhong; Wang, Guoyu

    2011-09-01

    A three dimensional numerical model of nonlinear wave action on a quasi-ellipse caisson in a time domain was developed in this paper. Navier-Stokes equations were solved by the finite difference method, and the volume of fluid (VOF) method was employed to trace the free surface. The partial cell method was used to deal with the irregular boundary typical of this type of problem during first-time wave interaction with the structure, and a satisfactory result was obtained. The numerical model was verified and used to investigate the effects of the relative wave height H/d, relative caisson width kD, and relative length-width ratio B/D on the wave forces of the quasi-ellipse caisson. It was shown that the relative wave height H/d has a significant effect on the wave forces of the caisson. Compared with the non-dimensional inline wave force, the relative length-width ratio B/D was shown to have significant influence on the non-dimensional transverse wave force.

  7. Theoretical Investigation of Peak-Delay Force Reduction for Caissons Exposed to Non-breaking Short-Crested Waves

    DEFF Research Database (Denmark)

    Burcharth, H. F.; Liu, Z.

    In nature coastal structures are exposed to oblique short-crested waves. The effect of wave incident angle on total wave force on a long caisson are twofold. The one is the force reduction due to the reduction of instantaneous point pressure on the caisson, named point-pressure force reduction....... The other is the force reduction due to the fact that the peak pressures do not occur simultaneously along the caisson, named peak-delay force reduction. These two reduction effects can also be expected with short-crested waves, as the short-crestedness of waves means the spreading of wave energy over...... a range of incident angles. The peak-delay force reduction, i.e. no simultaneous peak along caisson, is of particular interest because the equipment improvement in construction enables the building of considerably long caissons. In Japan length of caissons exceeds often 100m. This paper will concentrate...

  8. Radon hazard from caisson and tunnel construction in Kong Kong

    International Nuclear Information System (INIS)

    Lam, W.K.; Tsin, T.W.; Ng, T.P.

    1988-01-01

    A possible occupational risk of caisson and tunnel excavation in Hong Kong results from the inhalation of natural radon daughters. In this study radon daughter concentrations ranging from 0.001 to 71.4 WL were recorded in caissons of various dimensions and from 0.03 to 0.95 WL in tunnels over 1 km in length under construction (ICRP exposure limit being 0.4 WL). There was clear indication of increased radon daughter accumulation in confined and unventilated areas and in unventilated caissons an exponential increase of radon daughter concentration with the ratio of depth to cross-sectional area was observed (r=0.9). The study revealed a potential radiation hazard facing underground construction workers and this is being examined by an ongoing epidemiological cohort study: meanwhile environmental control should be improved. (UK)

  9. Experimental investigation on the relationship between sluice caisson shape of tidal power plant and the water discharge capability

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dal Soo; Oh, Sang-Ho; Yi, Jin-Hak; Park, Woo-Sun [Coastal Engineering and Ocean Energy Research Department, Korea Ocean Research and Development Institute, Ansan 426-744 (Korea); Cho, Hyu-Sang; Kim, Duk-Gu; Ahn, Suk-Jin [Technology Research and Development Institute, Hyein E and C Co. Ltd., Seoul 157-861 (Korea); Eom, Hyun-Min [Global Environment System Research Laboratory, National Institute of Meteorological Research/KMA, Seoul 156-720 (Korea)

    2010-10-15

    The change of water discharge capability of the sluice caisson of tidal power plant according to the change of geometrical shape of the sluice caisson was investigated by performing laboratory experiments. The major design parameters that constitute general shape of the sluice caisson were deduced and a total of 32 different shapes of sluice caisson models were subjected to the hydraulic experiments. For every sluice caisson model, the water discharge capability was estimated with five different flow rates and three different water level conditions. The experiments were carried out in an open channel flume with a great care to measure flow rate and water level accurately, which are key physical quantities in estimating the water discharge capability of the sluice caisson models. By analyzing the experimental results, influence of the respective design parameters on the performance of the sluice caisson was examined and the general guidelines to enhance the water discharge capability were suggested. The discharge coefficient of the best sluice caisson model ranged from 2.3 to 3.1 depending on the experimental conditions, which is far higher than the values that were adopted in the past feasibility studies in Korea. (author)

  10. Apparatus for ground water chemistry investigations in field caissons

    International Nuclear Information System (INIS)

    Cokal, E.J.; Stallings, E.; Walker, R.; Nyhan, J.W.; Polzer, W.L.; Essington, E.H.

    1985-01-01

    Los Alamos is currently in its second season of ground water chemistry and hydrology experimentation in a field facility that incorporates clusters of six, 3-meter-diameter by 6-meter-deep, soil-filled caissons and required ancillaries. Initial experience gained during the 1983 field season indicated the need for further development of the technology of this type of experimentation supporting hydrologic waste management research. Uniform field application of water/matrix solutions to the caisson, matrix and tracer solution blending/storage, and devices for ground water sampling are discussed

  11. Feeding kinematics, suction, and hydraulic jetting performance of harbor seals (Phoca vitulina.

    Directory of Open Access Journals (Sweden)

    Christopher D Marshall

    Full Text Available The feeding kinematics, suction and hydraulic jetting capabilities of captive harbor seals (Phoca vitulina were characterized during controlled feeding trials. Feeding trials were conducted using a feeding apparatus that allowed a choice between biting and suction, but also presented food that could be ingested only by suction. Subambient pressure exerted during suction feeding behaviors was directly measured using pressure transducers. The mean feeding cycle duration for suction-feeding events was significantly shorter (0.15±0.09 s; P<0.01 than biting feeding events (0.18±0.08 s. Subjects feeding in-water used both a suction and a biting feeding mode. Suction was the favored feeding mode (84% of all feeding events compared to biting, but biting comprised 16% of feeding events. In addition, seals occasionally alternated suction with hydraulic jetting, or used hydraulic jetting independently, to remove fish from the apparatus. Suction and biting feeding modes were kinematically distinct regardless of feeding location (in-water vs. on-land. Suction was characterized by a significantly smaller gape (1.3±0.23 cm; P<0.001 and gape angle (12.9±2.02°, pursing of the rostral lips to form a circular aperture, and pursing of the lateral lips to occlude lateral gape. Biting was characterized by a large gape (3.63±0.21 cm and gape angle (28.8±1.80°; P<0.001 and lip curling to expose teeth. The maximum subambient pressure recorded was 48.8 kPa. In addition, harbor seals were able to jet water at food items using suprambient pressure, also known as hydraulic jetting. The maximum hydraulic jetting force recorded was 53.9 kPa. Suction and hydraulic jetting where employed 90.5% and 9.5%, respectively, during underwater feeding events. Harbor seals displayed a wide repertoire of behaviorally flexible feeding strategies to ingest fish from the feeding apparatus. Such flexibility of feeding strategies and biomechanics likely forms the basis of their

  12. On the estimation method of compressed air consumption during pneumatic caisson sinking

    OpenAIRE

    平川, 修治; ヒラカワ, シュウジ; Shuji, HIRAKAWA

    1990-01-01

    There are several methods in estimation of compressed air consumption during pneumatic caisson sinking. It is re uired in the estimation of compressed air consumption by the methods under the same conditions. In this paper, it is proposed the methods which is able to estimate accurately the compressed air consumption during pnbumatic caissons sinking at this moment.

  13. 3D DIGITAL SIMULATION OF MINNAN TEMPLE ARCHITECTURE CAISSON'S CRAFT TECHNIQUES

    OpenAIRE

    Y. C. Lin; T. C. Wu; M. F. Hsu

    2013-01-01

    Caisson is one of the important representations of the Minnan (southern Fujian) temple architecture craft techniques and decorative aesthetics. The special component design and group building method present the architectural thinking and personal characteristics of great carpenters of Minnan temple architecture. In late Qing Dynasty, the appearance and style of caissons of famous temples in Taiwan apparently presented the building techniques of the great carpenters. However, as the y...

  14. Computer tomography in Caisson's disease

    International Nuclear Information System (INIS)

    Horvath, F.; Csobaly, S.; Institute for Advanced Training of Physicians, Budapest

    1981-01-01

    Computer tomography was performed on 20 patients with the early stages of Caisson osteoarthropathy, as well as in other patients with chronic bone infarcts. From their results the authors have formed the opinion that CT is valuable, not only in the diagnosis of early cases, but that it can provide significant information concerning the osteopathy and bone infarcts. (orig.) [de

  15. Laboratory Setup for Vertically Loaded Suction Caisson Foundation in Sand and Validation of Responses

    DEFF Research Database (Denmark)

    Manzotti, E.; Vaitkunaite, Evelina; Ibsen, Lars Bo

    during the last years and, following this trend, design choice will turn into foundation composed of three or four suction bucket foundations, called respectively tripod and tetrapod. Overturning moment in tripod and tetrapod is carried by vertical loading; therefore vertical pull-out capacity is tested......, in both static and cyclic case of loading. Testing rig and equipment are presented together with procedures. Tests results are presented in order to verify the output of tests. CPT-based methods and beta-methods to evaluate installation and pull-out resistance are then presented and implemented in Matlab...... in order to validate responses. It is demonstrated that kf parameter of CPT-based methods is dependent on the overburden pressure applied. Parameters of beta methods are analyzed and defined. Satisfying results are obtained with methods that are considering a linear increase or decrease with the depth...

  16. Application of importance sampling method in sliding failure simulation of caisson breakwaters

    Science.gov (United States)

    Wang, Yu-chi; Wang, Yuan-zhan; Li, Qing-mei; Chen, Liang-zhi

    2016-06-01

    It is assumed that the storm wave takes place once a year during the design period, and N histories of storm waves are generated on the basis of wave spectrum corresponding to the N-year design period. The responses of the breakwater to the N histories of storm waves in the N-year design period are calculated by mass-spring-dashpot mode and taken as a set of samples. The failure probability of caisson breakwaters during the design period of N years is obtained by the statistical analysis of many sets of samples. It is the key issue to improve the efficiency of the common Monte Carlo simulation method in the failure probability estimation of caisson breakwaters in the complete life cycle. In this paper, the kernel method of importance sampling, which can greatly increase the efficiency of failure probability calculation of caisson breakwaters, is proposed to estimate the failure probability of caisson breakwaters in the complete life cycle. The effectiveness of the kernel method is investigated by an example. It is indicated that the calculation efficiency of the kernel method is over 10 times the common Monte Carlo simulation method.

  17. Caisson disease of bone.

    Science.gov (United States)

    Gregg, P J; Walder, D N

    1986-09-01

    Caisson disease of bone, which may affect compressed air workers and divers, is characterized by regions of bone and marrow necrosis that may lead to secondary osteoarthrosis of the hip and shoulder joints. A review of the pathologic, radiologic, and clinical aspects demonstrated uncertainties in the exact etiology. Early diagnosis is often not possible because of the delayed appearance of radiologic abnormalities. Research into these two aspects of this condition was carried out by the Medical Research Council Decompression Sickness Research Team in Newcastle upon Tyne over a ten-year period (1972 to 1982). Because no suitable animal model exists for the study of this condition, bone and marrow necrosis was produced by embolism of bone blood vessels with glass microspheres. With this model, it was shown that the presence of bone and marrow necrosis could be detected by bone scintigraphy using 99mTc-MDP and by measuring changes in serum ferritin concentration at a much earlier stage than was possible by radiography. However, only the former method has proved useful in clinical practice. Investigations into the etiology of caisson disease of bone have shown evidence for an increase in marrow fat cell size resulting from hyperoxia. This phenomenon may play a role in the production and localization of gas bubble emboli, which are thought to be the cause of the bone and marrow necrosis.

  18. 3-D Effects Force Reduction of Short-Crested Non-Breaking Waves on Caissons

    DEFF Research Database (Denmark)

    Burcharth, H. F.; Liu, Z.

    1998-01-01

    The effect of wave short-crestedness on the horizontal wave force on a caisson is twofold. The one is the force reduction due to the reduction of point pressure on the caisson, named point-pressure reduction. The other is the force reduction due to the fact that the peak pressures do not occur si...

  19. Caisson structures in the Beaufort Sea 1982-1990 : characteristics, instrumentation and ice loads

    Energy Technology Data Exchange (ETDEWEB)

    Timco, G.W.; Johnston, M.E. [National Research Council of Canada, Ottawa, ON (Canada). Canadian Hydraulics Centre

    2002-11-01

    This report presents a comprehensive overview of the instrumentation, characteristics and measured ice loads on the caisson structures used for exploratory drilling in the Canadian Beaufort Sea during the 1970s and 1980s. The focus was placed on the Tarsiut Caissons, the Single Steel Drilling Caisson (SSDC), the Caisson Retained Island (CRI), and the Molikpaq. Details on the ice-load measuring instrumentation were provided for each of the drill sites featuring an ice-load measurement program. The results of global loads on the structures were presented as a Line Load (global load per width of the structure) and the Global Pressure (line load per ice thickness). The authors showed that global loads were a function of the ice macrostructure (level first-year sea ice, multi-year ice, first-year ridges, hummock fields, isolated floes). A general increase in the Line Load with increasing ice thickness was revealed through analysis. There was considerable scatter in the data, and the authors explained it by examining the failure mode of the ice during the interaction process. 36 refs., 4 tabs., 57 figs.

  20. EVALUATION OF SHEAR STRENGTH FOR UPPER SLABS OF CAISSON FOUNDATION BASED ON LOAD CARRYING MECHANISM

    Science.gov (United States)

    Hattori, Hisamichi; Tadokoro, Toshiya; Tanimura, Yukihiro; Nishioka, Hidetoshi; Watanabe, Tadatomo; Maruyama, Osamu

    In upper slabs of caisson foundation, a seismic desi gn is difficult with an incr ease in earthquake load. So we carried out loading tests and FEM analysis for upper slabs of caisson foundation. As a result, we proposed a new design method which takes into co nsideration the effective width on the pull out side based on crack pattern of test specimens, which is not considered in the existing design method. Moreover, we proposed a rational design method based on load carrying mechanism for upper slabs of caisson foundation.

  1. Experimental studies on caisson-type porous seawalls

    Science.gov (United States)

    Zhu, Shutang; Chwang, A. T.

    2002-08-01

    This paper presents experimental studies on the reflection characteristics of caisson-type porous seawalls under designed wave conditions. The results of physical model experiments are plotted and discussed. Comparisons between experimental results and analytical predictions are also made and the agreement is found to be very good.

  2. Insight into the lateral response of offshore shallow foundations

    DEFF Research Database (Denmark)

    Barari, Amin; Ibsen, Lars Bo

    2017-01-01

    Highlights •Suction caissons are often subjected to cyclic lateral loads caused by the action of wind or waves. •Excessive lateral deformations may be induced during a caisson’s service life. •Results of performance measure parameters for caissons harmonically oscillating on homogeneous soil are ...

  3. Dynamic stability analysis of caisson breakwater in lifetime considering the annual frequency of severe storm

    Science.gov (United States)

    Wang, Yu-chi; Wang, Yuan-zhan; Hong, Ning-ning

    2015-04-01

    In the dynamic stability analysis of a caisson breakwater, most of current studies pay attention to the motion characteristics of caisson breakwaters under a single periodical breaking wave excitation. And in the lifetime stability analysis of caisson breakwater, it is assumed that the caisson breakwater suffers storm wave excitation once annually in the design lifetime. However, the number of annual severe storm occurrence is a random variable. In this paper, a series of random waves are generated by the Wen Sheng-chang wave spectrum, and the histories of successive and long-term random wave forces are built up by using the improved Goda wave force model. It is assumed that the number of annual severe storm occurrence is in the Poisson distribution over the 50-year design lifetime, and the history of random wave excitation is generated for each storm by the wave spectrum. The response histories of the caisson breakwater to the random waves over 50-year design lifetime are calculated and taken as a set of samples. On the basis of the Monte Carlo simulation technique, a large number of samples can be obtained, and the probability assessment of the safety of the breakwater during the complete design lifetime is obtained by statistical analysis of a large number of samples. Finally, the procedure of probability assessment of the breakwater safety is illustrated by an example.

  4. Tissue holding device for use during surgical procedure, has contact body with suction foot and suction mouth that is surrounded by rim, and suction pipe connected to suction chamber

    OpenAIRE

    Vonck, D.; Goossens, R.H.M.; Flipsen, S.F.J.; Jakimowicz, J.J.; Van der Putten, E.P.W.

    2009-01-01

    The device has a locking ring (5), a connector (6), and a contact body (1) with a suction foot and a suction mouth (8), where the mouth is surrounded by a rim (10), which is substantially located in a plane of the suction foot. A suction chamber (9) has a sieve-shaped inner wall (2) and a transparent side wall, and a suction pipe (11) is connected to the chamber.

  5. Computer tomography in Caisson's disease

    Energy Technology Data Exchange (ETDEWEB)

    Horvath, F.; Csobaly, S.

    1981-07-01

    Computer tomography was performed on 20 patients with the early stages of Caisson osteoarthropathy, as well as in other patients with chronic bone infarcts. From their results the authors have formed the opinion that CT is valuable, not only in the diagnosis of early cases, but that it can provide significant information concerning the osteopathy and bone infarcts.

  6. Decompression syndrome (Caisson disease) in an Indian diver.

    Science.gov (United States)

    Phatak, Uday A; David, Eric J; Kulkarni, Pravin M

    2010-07-01

    Acute decompression syndrome (Caisson's disease) is an acute neurological emergency in divers. It is caused due to release of nitrogen gas bubbles that impinge the blood vessels of the spinal cord and brain and result in severe neurodeficit. There are very few case reports in Indian literature. There are multiple factors in the pathogenesis of Acute decompression syndrome (Caisson's disease) such as health problems in divers (respiratory problems or congenital heart diseases like atrial septal defect, patent ductus arteriosus etc), speed of ascent from the depth and habits like smoking that render divers susceptible for such neurological emergency. Usually, immediate diagnosis of such a condition with MRI is not possible in hospitals in the Coastal border. Even though, MRI is performed, it has very low specificity and sensitivity. Facilities like hyperbaric oxygen treatment are virtually non-existent in these hospitals. Therefore, proper education of the divers and appropriate preventive measures in professional or recreational divers is recommended.

  7. Hydraulic Response of Caisson Breakwaters in Multidirectional Breaking and Non-Breaking Waves

    DEFF Research Database (Denmark)

    Grønbech, J.; Kofoed, Jens Peter; Hald, Tue

    1998-01-01

    The present paper concerns the results and findings of a physical study on wave impacts on vertical caisson breakwaters situated in irregular, multidirectional breaking seas. The study has taken place as part of the framework programme "Dynamic of Structures" financially supported by the Danish T...... breaking waves at deep water. The study on wave overtopping showed that the 3D wave overtopping formula suggested by Franco et al., 1995b, predicts the wave overtopping reasonable well for both non breaking and breaking waves at deep water.......The present paper concerns the results and findings of a physical study on wave impacts on vertical caisson breakwaters situated in irregular, multidirectional breaking seas. The study has taken place as part of the framework programme "Dynamic of Structures" financially supported by the Danish...... induced loading and overtopping on caisson breakwaters situated in breaking seas. Regarding the wave forces only minor differences between breaking and non breaking waves in deep water were observed, and it was found that the prediction formula of Goda also seems to apply well for multidirectionally...

  8. Compilation of field-scale caisson data on solute transport in the unsaturated zone

    International Nuclear Information System (INIS)

    Polzer, W.L.; Essington, E.H.; Fuentes, H.R.; Nyhan, J.W.

    1986-11-01

    Los Alamos National Laboratory has conducted technical support studies to assess siting requirements mandated by Nuclear Regulatory Commission in 10 CFR Part 61. Field-scale transport studies were conducted under unsaturated moisture conditions and under steady and unsteady flow conditions in large caissons located and operated in a natural (field) environment. Moisture content, temperature, flow rate, base-line chemical, tracer influent, and tracer breakthrough data collected during tracer migration studies in the caisson are compiled in tables and graphs. Data suggest that the imposition of a period of drainage (influent solution flow was stopped) may cause an increase in tracer concentration in the soil solution at various sampling points in the caisson. Evaporation during drainage and diffusion of the tracers from immobile to mobile water are two phenomena that could explain the increase. Data also suggest that heterogeneity of sorption sites may increase the variability in transport of sorbing tracers compared with nonsorbing tracers

  9. [Hand-arm vibration syndrome in caisson miners].

    Science.gov (United States)

    Kákosy, T; Németh, L; Hazay, B; Posgay, M; Diner, J

    1997-07-06

    Authors examined 43 caisson-miners with symptoms of the upper extremities because of suspicion of hand-arm vibration syndrome. Also vibration measurements were performed on the pneumatic hammer used by the workers. The acceleration of the vibration exceeded 2.5-3.5 times the maximum allowable level according to the ISO 5349. Symptoms and signs of hand-arm vibration syndrome were found in 39 cases (90.7%). The vascular, peripheral neurological and locomotor system of the upper extremities were affected in similar frequency: 54.8; 51.6 and 51.2%, respectively. The most common angiological alteration was the Raynaud's phenomenon. Neurologically predominated the tunnel syndromes. Among the osteoarticular lesions the degenerative phenomena were the most frequent. In most cases more than one pathological alteration occurred. Fatigue fracture of the spinous process of vertebra D. I. appeared in one single case, degenerative changes of cervical spine in 34 patients (79.1%). The very common occurrence of the locomotor alterations and tunnel syndromes respectively can be explained probably also by the high physical stress required by this profession. The detailed examination of the locomotor system is very important by the periodical screening of the caisson-miners.

  10. Results of Caisson Breakwater Tests in Multidirectional Breaking Seas

    DEFF Research Database (Denmark)

    Kofoed, Jens Peter

    In extension of the work done at the Hydraulics and Coastal Engineering Laboratory, Dept. of Civil Engineering, Aalborg University, Denmark, described in Grønbech et al., 1997, laboratory tests has been performed investigating wave loading and overtopping on caisson breakwaters in multidirectional...

  11. Seismic performance of an existing bridge with scoured caisson foundation

    Science.gov (United States)

    Chang, Kuo-Chun; Sung, Yu-Chi; Liu, Kuang-Yen; Wang, Ping-Hsiung; Lee, Zheng-Kuan; Lee, Lu-Sheng; Witarto

    2014-08-01

    This paper presents in-situ seismic performance tests of a bridge before its demolition due to accumulated scouring problem. The tests were conducted on three single columns and one caisson-type foundation. The three single columns were 1.8 m in diameter, reinforced by 30-D32 longitudinal reinforcements and laterally hooped by D16 reinforcements with spacing of 20 cm. The column height is 9.54 m, 10.59 m and 10.37 m for Column P2, P3, and P4, respectively. Column P2 had no exposed foundation and was subjected to pseudo-dynamic tests with peak ground acceleration of 0.32 g first, followed by one cyclic loading test. Column P3 was the benchmark specimen with exposed length of 1.2 m on its foundation. The exposed length for Column P4 was excavated to 4 m, approximately 1/3 of the foundation length, to study the effect of the scouring problem to the column performance. Both Column P3 and Column P4 were subjected to cyclic loading tests. Based on the test results, due to the large dimension of the caisson foundation and the well graded gravel soil type that provided large lateral resistance, the seismic performance among the three columns had only minor differences. Lateral push tests were also conducted on the caisson foundation at Column P5. The caisson was 12 m long and had circular cross-sections whose diameters were 5 m in the upper portion and 4 m in the lower portion. An analytical model to simulate the test results was developed in the OpenSees platform. The analytical model comprised nonlinear flexural elements as well as nonlinear soil springs. The analytical results closely followed the experimental test results. A parametric study to predict the behavior of the bridge column with different ground motions and different levels of scouring on the foundation are also discussed.

  12. Analyses of Stability of Caisson Breakwaters on Rubble Foundation Exposed to Impulsive Loads

    DEFF Research Database (Denmark)

    Burcharth, Hans F.; Andersen, Lars; Andersen, Thomas Lykke

    2009-01-01

    The paper deals with the analysis of the overall stability of caisson breakwaters exposed to impulsive wave loadings, in particular regarding sliding failure and failure in the subsoil. A comparison is made between prediction of sliding distances by a simple onedimensional (1-D) dynamic analysis...... and a dynamic two-dimensional finite-element analysis based on the ABAQUS code. Only the last method includes the deformation characteristics of the rubble foundation and sand subsoil. It is shown that the simple 1-D analysis somewhat underestimates the horizontal sliding distance of the caisson. Stability...

  13. [Developing and testing of decompression regimes for caisson operations while constructing Moscow metro].

    Science.gov (United States)

    Rodchenkov, S V; Syrovegin, A V; Shulagin, I A

    1996-01-01

    Decompression regimes for caisson operations at the pressures up to 5 ata exceeding duration of the regimes specified in the caisson regulations have been developed. The regimes were tested and validated in dry altitude chamber with participation of exercising human subjects. Seventeen test-subjects took part in 54 tests. No symptoms of decompression sickness were documented. Air embolism was observed in 28 +/- 6% of cases at rest and in 72 +/- 6% of cases following provocative leg movements. The air embolism expression tended to increase with exposure to pressure.

  14. Compressed air tunneling and caisson work decompression procedures: development, problems, and solutions.

    Science.gov (United States)

    Kindwall, E P

    1997-01-01

    Multinational experience over many years indicates that all current air decompression schedules for caisson and compressed air tunnel workers are inadequate. All of them, including the Occupational Safety and Health Administration tables, produce dysbaric osteonecrosis. The problem is compounded because decompression sickness (DCS) tends to be underreported. Permanent damage in the form of central nervous system or brain damage may occur in compressed air tunnel workers, as seen on magnetic resonance imaging, in addition to dysbaric osteonecrosis. Oxygen decompression seems to be the only viable method for safely decompressing tunnel workers. Oxygen decompression of tunnel workers has been successfully used in Germany, France, and Brazil. In Germany, only oxygen decompression of compressed air workers is permitted. In our experience, U.S. Navy tables 5 and 6 usually prove adequate to treat DCS in caisson workers despite extremely long exposure times, allowing patients to return to work following treatment for DCS. Tables based on empirical data and not on mathematical formulas seem to be reasonably safe. U.S. Navy Exceptional Exposure Air Decompression tables are compared with caisson tables from the United States and Great Britain.

  15. Prediction method of seismic residual deformation of caisson quay wall in liquefied foundation

    Science.gov (United States)

    Wang, Li-Yan; Liu, Han-Long; Jiang, Peng-Ming; Chen, Xiang-Xiang

    2011-03-01

    The multi-spring shear mechanism plastic model in this paper is defined in strain space to simulate pore pressure generation and development in sands under cyclic loading and undrained conditions, and the rotation of principal stresses can also be simulated by the model with cyclic behavior of anisotropic consolidated sands. Seismic residual deformations of typical caisson quay walls under different engineering situations are analyzed in detail by the plastic model, and then an index of liquefaction extent is applied to describe the regularity of seismic residual deformation of caisson quay wall top under different engineering situations. Some correlated prediction formulas are derived from the results of regression analysis between seismic residual deformation of quay wall top and extent of liquefaction in the relative safety backfill sand site. Finally, the rationality and the reliability of the prediction methods are validated by test results of a 120 g-centrifuge shaking table, and the comparisons show that some reliable seismic residual deformation of caisson quay can be predicted by appropriate prediction formulas and appropriate index of liquefaction extent.

  16. From Julius Caesar to Sustainable Composite Materials: A Passage through Port Caisson Technology

    Directory of Open Access Journals (Sweden)

    Eduardo Cejuela

    2018-04-01

    Full Text Available The breakwater construction technique using floating concrete caissons is well-known nowadays as a widespread system. Yet do we really know its origin? Since Julius Caesar used this technology in Brindisi (Italy up to the Normandy landings in June 1944, not only has this technology been developed, but it has been a key item in several moments in history. Its development has almost always been driven by military requirements. The greatest changes have not been conceptual but point occurring, backed by the materials used. Parallelisms can be clearly seen in each new stage: timber, opus caementitium (Roman concrete, iron and concrete… However, nowadays, achieving a more sustainable world constitutes a major challenge, to which the construction of caissons breakwaters must contribute as a field of application of new eco-friendly materials. This research work provides a general overview from the origins of caissons until our time. It will make better known the changes that took place in the system and their adaptation to new materials, and will help in clarifying the future in developing technology towards composite sustainable materials and special concrete. If we understand the past, it will be easier to define the future.

  17. Seismic response of bridge pier on rigid caisson foundation in soil stratum

    Science.gov (United States)

    Tsigginos, C.; Gerolymos, N.; Assimaki, D.; Gazetas, G.

    2008-03-01

    An analytical method to study the seismic response of a bridge pier supported on a rigid caisson foundation embedded in a deep soil stratum underlain by a homogeneous half space is developed. The method reproduces the kinematic and inertial responses, using translational and rotational distributed Winkler springs and dashpots to simulate the soil-caisson interaction. Closed-form solutions are given in the frequency domain for vertical harmonic S-wave excitation. Comparison with results from finite element (FE) analysis and other available solutions demonstrates the reliability of the model. Results from parametric studies are given for the kinematic and inertial responses. The modification of the fundamental period and damping ratio of the bridge due to soil-structure interaction is graphically illustrated.

  18. Wave Impacts on Caisson Breakwaters Situated in Multidirectionally Breaking Seas

    DEFF Research Database (Denmark)

    Grønbech, J.; Burcharth, Hans F.; Frigaard, Peter

    1999-01-01

    Attention has been addressed to the effects of wave obliquity and multidirectionality on the wave loads on vertical caisson breakwaters situated in non breaking seas. Within the joint European (MAST-LIP-TAW) research project, a 3D model investigation was carried out at Delft Hydraulics to assess...

  19. Conceptual Design of Portable Filtered Air Suction Systems For Prevention of Released Radioactive Gas under Severe Accidents of NPP

    Energy Technology Data Exchange (ETDEWEB)

    Gu, Beom W.; Choi, Su Y.; Yim, Man S.; Rim, Chun T. [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2014-05-15

    It becomes evident that severe accidents may occur by unexpected disasters such as tsunami, heavy flood, or terror. Once radioactive material is released from NPP through severe accidents, there are no ways to prevent the released radioactive gas spreading in the air. As a remedy for this problem, the idea on the portable filtered air suction system (PoFASS) for the prevention of released radioactive gas under severe accidents was proposed. In this paper, the conceptual design of a PoFASS focusing on the number of robot fingers and robot arm rods are proposed. In order to design a flexible robot suction nozzle, mathematical models for the gaps which represent the lifted heights of extensible covers for given convex shapes of pipes and for the covered areas are developed. In addition, the system requirements for the design of the robot arms of PoFASS are proposed, which determine the accessible range of leakage points of released radioactive gas. In this paper, the conceptual designs of the flexible robot suction nozzle and robot arm have been conducted. As a result, the minimum number of robot fingers and robot arm rods are defined to be four and three, respectively. For further works, extensible cover designs on the flexible robot suction nozzle and the application of the PoFASS to the inside of NPP should be studied because the radioactive gas may be released from connection pipes between the containment building and auxiliary buildings.

  20. Wave Loading and Overtopping on Caisson Breakwaters in Multidirectional Breaking Seas

    DEFF Research Database (Denmark)

    Grønbech, J.; Hald, Tue; Frigaard, Peter

    1997-01-01

    The present paper concerns the results and findings of a physical study on wave impacts on vertical caisson breakwaters situated in irregular, multidirectional breaking seas. The study has taken place as a part of the framework programme "Dynamics of Structures" financially supported by the Danish...

  1. A STUDY ON THE EARTHQUAKE RESPONSE AND EARTHQUAKE RESISTANT DESIGN METHOD OF AN OPEN TYPE WHARF WITH PNEUMATIC CAISSONS

    Science.gov (United States)

    Oishi, Masahiko; Nagao, Takashi; Shigeki, Kouji; Ouchi, Masatoshi; Sato, Yuske; Kinomiya, Osamu

    Seismic response of an open type wharf with pneumatic caisson was clarified using a dynamic finite element method. As a result, rocking behavior of caisson foundations were observed and applicability of a frame model analysis to the earthquake resistant design of a wharf was suggested. Authors proposed the framework of earthquake resistant design method of the wharf including the evaluation method of response acceleration of the wharf.

  2. Modelling of Performance of Caisson Type Breakwaters under Extreme Waves

    Science.gov (United States)

    Güney Doǧan, Gözde; Özyurt Tarakcıoǧlu, Gülizar; Baykal, Cüneyt

    2016-04-01

    Many coastal structures are designed without considering loads of tsunami-like waves or long waves although they are constructed in areas prone to encounter these waves. Performance of caisson type breakwaters under extreme swells is tested in Middle East Technical University (METU) Coastal and Ocean Engineering Laboratory. This paper presents the comparison of pressure measurements taken along the surface of caisson type breakwaters and obtained from numerical modelling of them using IH2VOF as well as damage behavior of the breakwater under the same extreme swells tested in a wave flume at METU. Experiments are conducted in the 1.5 m wide wave flume, which is divided into two parallel sections (0.74 m wide each). A piston type of wave maker is used to generate the long wave conditions located at one end of the wave basin. Water depth is determined as 0.4m and kept constant during the experiments. A caisson type breakwater is constructed to one side of the divided flume. The model scale, based on the Froude similitude law, is chosen as 1:50. 7 different wave conditions are applied in the tests as the wave period ranging from 14.6 s to 34.7 s, wave heights from 3.5 m to 7.5 m and steepness from 0.002 to 0.015 in prototype scale. The design wave parameters for the breakwater were 5m wave height and 9.5s wave period in prototype. To determine the damage of the breakwater which were designed according to this wave but tested under swell waves, video and photo analysis as well as breakwater profile measurements before and after each test are performed. Further investigations are carried out about the acting wave forces on the concrete blocks of the caisson structures via pressure measurements on the surfaces of these structures where the structures are fixed to the channel bottom minimizing. Finally, these pressure measurements will be compared with the results obtained from the numerical study using IH2VOF which is one of the RANS models that can be applied to simulate

  3. Chapter 4: Pulsating Wave Loads Section 4.3: 3D Effects Force Reduction of Short-Crested Non-Breaking Waves on Caissons

    DEFF Research Database (Denmark)

    Burcharth, Hans F.; Liu, Zhou

    1999-01-01

    The effect of wave short-crestedness on the horizontal wave force on a caisson is twofold. The one is the force reduction due to the reduction of point pressure on the caisson, named point-pressure reduction. The other is the force reduction due to the fact that the peak pressures do not occur si...

  4. Risk analysis of breakwater caisson under wave attack using load surface approximation

    Science.gov (United States)

    Kim, Dong Hyawn

    2014-12-01

    A new load surface based approach to the reliability analysis of caisson-type breakwater is proposed. Uncertainties of the horizontal and vertical wave loads acting on breakwater are considered by using the so-called load surfaces, which can be estimated as functions of wave height, water level, and so on. Then, the first-order reliability method (FORM) can be applied to determine the probability of failure under the wave action. In this way, the reliability analysis of breakwaters with uncertainties both in wave height and in water level is possible. Moreover, the uncertainty in wave breaking can be taken into account by considering a random variable for wave height ratio which relates the significant wave height to the maximum wave height. The proposed approach is applied numerically to the reliability analysis of caisson breakwater under wave attack that may undergo partial or full wave breaking.

  5. Hydroponic Feed With Suction

    Science.gov (United States)

    Cox, William M.; Brown, Christopher S.; Dreschel, Thomas W.

    1994-01-01

    Placing nutrient solution under suction increases growth. Foam plug seals growing stem of plant, making it possible to maintain suction in nutrient liquid around roots. Jar wrapped in black tape to keep out light. Potential use in terrestrial applications in arid climates or in labor-intensive agricultural situations.

  6. [The radiological findings of caisson-induced bone infarcts. The relationship between acute arthralgia and bone infarcts (author's transl)].

    Science.gov (United States)

    Horváth, V F

    1978-07-01

    The radiological features, such as calcification in long bones due to infarcts, resulting from Caisson disease are described by the author on the basis of an extensive experience. The similar localisation of acute "arthralgia" and bone infarcts make it appear probable that the infarcts play a primary role in the production of "osteo-articular" pain. The author stresses the advisability of examining the adjacent portions of the tibia and femur at the initial pre-employment examination, since bone infarcts can be caused by a variety of conditions other than work in Caissons.

  7. Effect of Short-Crestedness and Obliquity on Non-Breaking and Breaking Wave Forces Applied to Vertical Caisson Breakwaters

    DEFF Research Database (Denmark)

    Martinelli, Luca; Lamberti, Alberto; Frigaard, Peter

    2007-01-01

    This paper addresses wave forces applied to vertical caisson breakwaters. Design diagrams are proposed to evaluate the reduction of the breaker wave force with increasing horizontal length of the units. A model in 1:100 scale of a typical Italian vertical breakwater was tested under multidirectio......This paper addresses wave forces applied to vertical caisson breakwaters. Design diagrams are proposed to evaluate the reduction of the breaker wave force with increasing horizontal length of the units. A model in 1:100 scale of a typical Italian vertical breakwater was tested under...

  8. Decompression sickness in caisson workers

    Science.gov (United States)

    Ghawabi, Samir H. El; Mansour, Mohamed B.; Youssef, Fatma L.; Ghawabi, Mohamed H. El; Latif, Mohamed M. Abd El

    1971-01-01

    El Ghawabi, S. H., Mansour, M. B., Youssef, F. L., El Ghawabi, M. H., and Abd El Latif, M. M. (1971).Brit. J. industr. Med.,28, 323-329. Decompression sickness in caisson workers. An investigation of 55 bridge construction workers is reported. The overall bends rate was 0·97%. (The term `bends' as used in this study is defined in the paper.) Chokes were encountered in 67·27% of workers. A clinical, haematological, and radiological study was performed. Definite bony changes were found in 43·6% of all workers; 91·6% of these had lesions around the elbow. The presence of dense areas in the neck of the scapula is reported in two cases for the first time. The relatively high haematocrit value is thought to play a part in the pathogenesis of bone infarction through its relation with blood viscosity. Images PMID:5124832

  9. [Great depth pneumatic caisson and its load work involved with the efficiency of respiratory protection].

    Science.gov (United States)

    Shibayama, M; Oda, S; Takeuchi, J; Ikeda, Y; Yamamura, I; Mano, Y

    1989-07-01

    Pneumatic caisson work in Japan has been in operation since 1924. Afterward, this technique of compressed air work has been utilized in the constructions like as foundation works, the basements, and shafts of the bottom tunnel or shields for subway and so forth. While, it means for people to be exposed to hyperbaric environment that they use compressed air work, this technique has risks to be suffered from not only decompression sickness (DCS) but toxicity of poisonous gas or oxygen deficiency. However, this technique is necessary for urban civil engineering and recent compressed air works over than 1.0 kg/cm2 has been increased in 1.5 times more than in 1970's and the higher compressed air work more than 4.0 kg/cm2 will be actually planned in near future. So unmanned caisson work is considered as a better technique for such high pressure work, even though people must enter into hyperbaric working fields for maintenance or repair of unmanned operated machinery and materials. This research is to establish the safety work under hyperbaric environment within 7 kg/cm2. It is necessary for us to establish the system not only to keep safety but to maintain working efficiency. According to obtain the purpose, the effect of respiratory protection has been investigated and work load under hyperbaric caisson work has also been studied.

  10. Analyses of Stability of Caisson Breakwaters on Rubble Foundation Exposed to Impulsive Loads

    DEFF Research Database (Denmark)

    Burcharth, Hans F.; Andersen, Lars; Andersen, Thomas Lykke

    2009-01-01

    and a dynamic two-dimensional finite-element analysis based on the ABAQUS code. Only the last method includes the deformation characteristics of the rubble foundation and sand subsoil. It is shown that the simple 1-D analysis somewhat underestimates the horizontal sliding distance of the caisson. Stability...

  11. Suction is kid's play: extremely fast suction in newborn seahorses

    Science.gov (United States)

    Van Wassenbergh, Sam; Roos, Gert; Genbrugge, Annelies; Leysen, Heleen; Aerts, Peter; Adriaens, Dominique; Herrel, Anthony

    2009-01-01

    Ongoing anatomical development typically results in a gradual maturation of the feeding movements from larval to adult fishes. Adult seahorses are known to capture prey by rotating their long-snouted head extremely quickly towards prey, followed by powerful suction. This type of suction is powered by elastic recoil and requires very precise coordination of the movements of the associated feeding structures, making it an all-or-none phenomenon. Here, we show that newborn Hippocampus reidi are able to successfully feed using an extremely rapid and powerful snout rotation combined with a high-volume suction, surpassing that observed in adult seahorses. An inverse dynamic analysis shows that an elastic recoil mechanism is also used to power head rotation in newborn H. reidi. This illustrates how extreme levels of performance in highly complex musculoskeletal systems can be present at birth given a delayed birth and rapid development of functionally important structures. The fact that the head skeleton of newborn seahorses is still largely cartilaginous may not be problematic because the hydrodynamic stress on the rotating snout appeared considerably lower than in adult syngnathids. PMID:19324657

  12. PERBEDAAN PARAMETER KARDIOPULMONAL SETELAH TINDAKAN OPEN SUCTION

    Directory of Open Access Journals (Sweden)

    Muhamat Nofiyanto

    2013-12-01

    Full Text Available Background: Endotracheal suctioning is often performed by nurses and beneficial for critically ill patients. Suctioning is essential for removing secretions, maintaining airway patency and prevent unexpected complications. Open suctioning is performed by disconnecting patients with the ventilator. Suctioning not only removed secretions in the airway but also oxygen. Suctioning must be done correctly, safely, effectively and efficiently to prevent unexpected events in critically ill patients. Objective: This study aimed to determine differences on cardiopulmonary parameters after open suction in critically ill patients Methods: The study design was comparatif cross sectional analytic approach, using one group pre test and post test. The sample of the research amounted to 34 people, using purposive sampling technique. Catheter size 14 Fr on ETT number 7 mm used in this research to performed endotracheal suctioning. Cardiopulmonary parameters (Heart rate/ HR, respiratory rate/RR, oxygen saturation/SpO2, systolic blood pressure/ SBP and diastolic blood pressure/DBP measured by pulse oxymeter and bedside monitor before suction and immediately thereafter. Results: The results showed increase average heart rate 6.412 (from 106.62 into 113.03, Respiratory rate has increased 4.971 (from 20.62 into 25.59, SpO2 decreased 1.68 (from 99.09 into 97.41, and systolic blood pressure increased 5.71 (from 118.29 into 124.00 after performed open suction. The results of paired t-test statistical analysis (for RR, HR obtained a < 0.05 (0.000, whereas Wilcoxon statistical analysis (for SpO2, SBP obtained a < 0.05 (0.000 and 0.001. So it can be said that the difference cardiopulmonary parameters was statistically significant after perfomed open suction in critically ill patients.

  13. Prototype bucket foundation for wind turbines

    DEFF Research Database (Denmark)

    Ibsen, Lars Bo; Liingaard, Morten

    The first full scale prototype bucket foundation for wind turbines has been installed in October 2002 at Aalborg University offshore test facility in Frederikshavn, Denmark. The suction caisson and the wind turbine have been equipped with an online monitoring system, consisting of 15 accelerometers...... and a real-time data-acquisition system. The report concerns the in service performance of the wind turbine, with focus on estimation of the natural frequencies of the structure/foundation. The natural frequencies are initially estimated by means of experimental Output-only Modal analysis. The experimental...... estimates are then compared with numerical simulations of the suction caisson foundation and the wind turbine. The numerical model consists of a finite element section for the wind turbine tower and nacelle. The soil-structure interaction of the soil-foundation section is modelled by lumped-parameter models...

  14. Scaled multiple holes suction tip for microneurosurgery; Technical note

    Directory of Open Access Journals (Sweden)

    Abdolkarim Rahmanian, Associate Professor of Neurosurgery

    2017-12-01

    Conclusion: The new suction tip permits easy and precise adjustment of suction power in microneurosirgical operations. Our scaled 3 and 4-hole suction tip is a simple and useful device for controlling the suction power during the microneurosurgeical procedures.

  15. Three-Dimensional Model Test Study of Modified Caisson Breakwater at Port of Castellon, Spain

    DEFF Research Database (Denmark)

    Nørgaard, Jørgen Harck; Andersen, Thomas Lykke

    caisson breakwater at Port of Castellon, Spain, tested earlier (Nørgaard & Lykke Andersen, 2013). Associate Prof. Thomas Lykke Andersen and M.Sc. Jørgen Quvang Harck Nørgaard were in charge of the model tests. Engineer assistant Niels Drustrup assisted in the laboratory with the construction...

  16. Evaluation of hypopharyngeal suction to eliminate aspiration: the Retro-Esophageal Suction (REScue) catheter.

    Science.gov (United States)

    Belafsky, Peter C; Mehdizadeh, O B; Ledgerwood, L; Kuhn, M

    2015-02-01

    Profound oropharyngeal dysphagia (OPD) is common and costly. Treatment options are limited. The purpose of this investigation was to evaluate the utility of hypopharyngeal suction at the upper esophageal sphincter (UES) to eliminate aspiration. Five different catheters were passed retrograde up the esophagus and positioned at the UES in a cadaver model of profound OPD. Suction was affixed to each catheter. 10 cc of barium was administered into the pyriform sinus, and videofluoroscopy was utilized to evaluate the presence of aspiration. 6 trials were administered per catheter and for a no catheter control. The outcome measures were the incidence of aspiration, the NIH Swallow Safety Scale (NIH-SSS), and UES opening. Control trials with no suction resulted in an aspiration rate of 100 % (6/6 trials). Negative pressure through 16, 18, 24, and 30 Fr catheter resulted in an aspiration rate of 0 % (0/24 trials; p  0.05). The mean NIH-SSS improved from 7.0 (±0.0) in the control to 0 (±0.0) with hypopharyngeal suction (18 Fr nasogastric catheter; p 12 Fr) at the level of the UES reduced aspiration by 100 % and significantly increased UES opening in a cadaveric model of profound oropharyngeal dysphagia.

  17. Evaluation of decompression tables by Doppler technique in caisson work in The Netherlands.

    Science.gov (United States)

    Breedijk, J H; Van der Putten, G J G M; Schrier, L M; Sterk, W

    2009-01-01

    Hyperbaric work was conducted for constructing an underground tramway in the Netherlands. A total of 11,647 exposures were conducted in 41,957 hours. For these working conditions specifically developed oxygen decompression tables were used. Fifteen workers were submitted to Doppler monitoring after caisson work at a depth at 12 msw. Measurements were done according to the Canadian DCIEM protocol. For bubble grading the Kisman-Masurel 12-points ordinal scale (0-IV) was used. Bubbles were detected in 17 of the 38 examinations. The highest grade (III-) was found in four measurements. At rest the grading was never higher than I+. Two hours after decompression the grading was remarkably higher than after one hour. Bubble scores were relatively low, although the maximum grading probably is not reached within two hours after decompression. It may be concluded that the oxygen decompression tables used, were reliable under these heavy working conditions. At group level, decompression stress can be evaluated by Doppler monitoring. In order to reduce health hazard of employees, use of oxygen during decompression in caisson work should be embodied in the occupational standard.

  18. Simulation study of intentional tritium release experiments in the caisson assembly for tritium safety at the TPL/JAERI

    International Nuclear Information System (INIS)

    Iwai, Y.; Hayashi, T.; Kobayashi, K.; Nishi, M.

    2001-01-01

    At the Tritium Process Laboratory (TPL) in Japan Atomic Energy Research Institute (JAERI), Caisson assembly for tritium safety study (CATS) with 12 m 3 of large airtight vessel (Caisson) was fabricated for confirmation and enhancement of fusion reactor safety to estimate the tritium behavior in the case, where the tritium leak accident should happen. One of the principal objectives of the present studies is the establishment of simulation method to predict the tritium behavior after the tritium leak accident should happen in a ventilated room. As for the understanding of initial tritium behavior until the tritium concentration become steady, the precise estimation of local flow rate in a room and time-dependent release behavior from the leak point are essential to predict the tritium behavior by simulation code. The three-dimensional eddy flow model considering, tritium-related phenomena was adopted to estimate the local flow rate in the 50 m 3 /h ventilated Caisson. The time-dependent tritium release behavior from the sample container was calculated by residence time distribution function. The calculated tritium concentrations were in good agreement with the experimental observations. The primary removal tritium behavior was also investigated by another code. Tritium gas concentrations decreased logarithmically to the time by ventilation. These observations were understandable by the reason that the flow in the ventilated Caisson was regarded as the perfectly mixing flow. The concentrations of tritiated water measured, and indications of tritium concentration by tritium monitors became gradually flat. This phenomena called 'tritium soaking effect' was found to be reasonably explained by considering the contribution of the exhaustion velocity by ventilation system, and the adsorption and desorption reaction rate of tritiated water on the wall material which is SUS 304. The calculated tritium concentrations were in good agreement with the experimental observations

  19. Vertical Dynamic Stiffness of Offshore Foundations

    DEFF Research Database (Denmark)

    Latini, Chiara; Cisternino, Michele; Zania, Varvara

    2016-01-01

    Nowadays, pile and suction caisson foundations are widely used to support offshore structures which are subjected to vertical dynamic loads. The dynamic soil-structure interaction of floating foundations (foundations embedded in a soil layer whose height is greater than the foundation length) is ...

  20. Prototype bucket foundation for wind turbines - natural frequency estimation

    Energy Technology Data Exchange (ETDEWEB)

    Ibsen, Lars Bo; Liingaard, M.

    2006-12-15

    The first full scale prototype bucket foundation for wind turbines has been installed in October 2002 at Aalborg University offshore test facility in Frederikshavn, Denmark. The suction caisson and the wind turbine have been equipped with an online monitoring system, consisting of 15 accelerometers and a real-time data-acquisition system. The report concerns the in service performance of the wind turbine, with focus on estimation of the natural frequencies of the structure/foundation. The natural frequencies are initially estimated by means of experimental Output-only Modal analysis. The experimental estimates are then compared with numerical simulations of the suction caisson foundation and the wind turbine. The numerical model consists of a finite element section for the wind turbine tower and nacelle. The soil-structure interaction of the soil-foundation section is modelled by lumped-parameter models capable of simulating dynamic frequency dependent behaviour of the structure-foundation system. (au)

  1. Evaluation of wave loads on a new type of perforated caisson

    OpenAIRE

    Vazquez, Miguel Angel; Negro, Vicente; Lopez-Gutierrez, Jose Santos; Monso de Prat, José Luis

    2016-01-01

    Permission is granted by ICE Publishing to print one copy for personal use. Any other use of these PDF files is subject to reprint fees. A new type of perforated breakwater has been tested combining the advantages of cylindrical geometry with stepped wave energy dissipation. Thus, the new type of caisson implies a significant reduction of maximum wave forces, as well as loads transmitted to the foundation in comparison with conventional vertical breakwater and other types of perforated cai...

  2. Place Atrium to Water Seal (PAWS): Assessing Wall Suction Versus No Suction for Chest Tubes After Open Heart Surgery.

    Science.gov (United States)

    Kruse, Tamara; Wahl, Sharon; Guthrie, Patricia Finch; Sendelbach, Sue

    2017-08-01

    Traditionally chest tubes are set to -20 cm H 2 O wall suctioning until removal to facilitate drainage of blood, fluid, and air from the pleural or mediastinal space in patients after open heart surgery. However, no clear evidence supports using wall suction in these patients. Some studies in patients after pulmonary surgery indicate that using chest tubes with a water seal is safer, because this practice decreases duration of chest tube placement and eliminates air leaks. To show that changing chest tubes to a water seal after 12 hours of wall suction (intervention) is a safe alternative to using chest tubes with wall suction until removal of the tubes (usual care) in patients after open heart surgery. A before-and-after quality improvement design was used to evaluate the differences between the 2 chest tube management approaches in chest tube complications, output, and duration of placement. A total of 48 patients received the intervention; 52 received usual care. The 2 groups (intervention vs usual care) did not differ significantly in complications (0 vs 2 events; P = .23), chest tube output (H 1 = 0.001, P = .97), or duration of placement (median, 47 hours for both groups). Changing chest tubes from wall suction to water seal after 12 hours of wall suction is a safe alternative to using wall suctioning until removal of the tubes. ©2017 American Association of Critical-Care Nurses.

  3. Tritium safety study using Caisson Assembly (CATS) at TPL/JAEA

    International Nuclear Information System (INIS)

    Hayashi, T.; Kobayashi, K.; Iwai, Y.; Isobe, K.; Nakamura, H.; Kawamura, Y.; Shu, W.; Suzuki, T.; Yamada, M.; Yamanishi, T.

    2008-01-01

    Tritium confinement is required as the most important safety Junction for a fusion reactor. In order to demonstrate the confinement performance experimentally, an unique equipment, called CATS: Caisson Assembly for Tritium Safety study, was installed in Tritium Process Laboratory of Japan Atomic Energy Agency and operated for about 10 years. Tritium confinement and migration data in CATS have been accumulated and dynamic simulation code was accumulated using these data. Contamination and decontamination behavior on various materials and new safety equipment functions have been investigated under collaborations with a lot of laboratories and universities. (authors)

  4. SWEEP Project RAT

    DEFF Research Database (Denmark)

    Ibsen, Lars Bo; Madsen, Søren; Petersen, L. B.

    This report presents the results from the design analyses made for the clustered suction caisson used as foundation for a Riser Access Tower (RAT). The RAT is intended built next to the K15-FA-1 Platform in the Dutch Sector of the North Sea....

  5. Buckling Analysis of Bucket Foundations for Wind Turbines in Deep Water

    DEFF Research Database (Denmark)

    Madsen, Søren; Andersen, Lars; Ibsen, Lars Bo

    2011-01-01

    Using large suction caissons for offshore wind turbines is an upcoming technology also referred to as bucket foundations. The bucket foundation does not require heavy installation equipment, but since it is constructed as a thin steel shell structure, instability, in form of buckling, becomes...

  6. MRI-based detection of an edema of the spinal cord in a patient with reversible M. Caisson

    International Nuclear Information System (INIS)

    Fellner, F.

    1998-01-01

    The concluding statement is that MR imaging detects lesions of the spinal cord in connection with a M. Caisson type II, and also is a suitable method for follow-up controls during treatment. (orig./CB) [de

  7. Special Foundation by means of reinforced-concrete caisson in Valencia Port; Cimentaciones especiales de los cajones del Muello Este. Puerto de Valencia

    Energy Technology Data Exchange (ETDEWEB)

    Gama Costa, P. M.

    2010-07-01

    This paper describes the process to construct a foundation by means of reinforced-concrete caisson on breakwaters. the project required to develop minimal dredging solutions as well as to improve the foundation areas of the what caissons. The improvement technique applied to the foundation area was based on gravel columns, since this solution was the most suitable for areas with high fine fraction contents, as it was the case. Gravel columns were executed following a bottom-feed method, and two different techniques: gravel tank top-feeding and gravel pumping. (Author)

  8. Embedment Effects on Vertical Bearing Capacity of Offshore Bucket Foundations on Cohesionless Soil

    DEFF Research Database (Denmark)

    Barari, Amin; Ibsen, Lars Bo; Ghalesari, Abbasali Taghavi

    2017-01-01

    This paper presents the results from a series of physical modeling and three-dimensional finite 9 element (FE) analyses, which examined the uniaxial vertical capacity of suction caissons for 10 offshore wind turbines. The experiments were carried out in quartz sand and involved monotonic 11 appli...

  9. Preliminary study of efficacy of cup suction in the correction of typical pectus excavatum.

    Science.gov (United States)

    Lopez, Manuel; Patoir, Arnaud; Costes, Frederic; Varlet, François; Barthelemy, Jean-Claude; Tiffet, Olivier

    2016-01-01

    duration of 9 months (2-22). Treatment using cup suction is a promising useful alternative in selected cases of symmetric and asymmetric PE, providing that the thorax is flexible. Treatment duration is directly linked to age, severity and the frequency of use. It is becoming a well-recognized therapy, which improves the self-image of those patients whose anterior chest wall is still pliable. The cup suction can be used for pediatrics and young adults waiting for a treatment, possibly surgery, however, the long-term effect of this procedure remains unclear. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Application of lumped-parameter models

    DEFF Research Database (Denmark)

    Ibsen, Lars Bo; Liingaard, Morten

    This technical report concerns the lumped-parameter models for a suction caisson with a ratio between skirt length and foundation diameter equal to 1/2, embedded into an viscoelastic soil. The models are presented for three different values of the shear modulus of the subsoil (section 1.1). Subse...

  11. Boundary layer on a flat plate with suction

    International Nuclear Information System (INIS)

    Favre, A.; Dumas, R.; Verollet, E.

    1961-01-01

    This research done in wind tunnel concerns the turbulent boundary layer of a porous flat plate with suction. The porous wall is 1 m long and begins 1 m downstream of the leading edge. The Reynolds number based on the boundary layer thickness is of the order of 16.300. The suction rate defined as the ratio of the velocity perpendicular to the wall to the external flow velocity ranges from 0 to 2 per cent. The pressure gradient can be controlled. The mean velocity profiles have been determined for various positions and suction rates by means of total pressure probes together with the intensities of the turbulent velocity fluctuations components, energy spectra and correlations by means of hot wire anemometers, spectral analyser and correlator. The stream lines, the values of the viscous and turbulent shear stresses, of the local wall friction, of the turbulent energy production term, with some information on the dissipation of the energy have been derived from these measurements. For these data the integral of equation of continuity in boundary layer have been drawn. The suction effects on the boundary layer are important. The suction thoroughly alters the mean velocity profiles by increasing the viscous shear stresses near the wall and decreasing them far from the wall, it diminishes the longitudinal and transversal turbulence intensities, the turbulent shear stresses, and the production of energy of turbulence. These effects are much stressed in the inner part of the boundary layer. On the other hand the energy spectra show that the turbulence scale is little modified, the boundary layer thickness being not much diminished by the suction. The suction effects can be appreciated by comparing twice the suction rate to the wall friction coefficient (assumed airtight), quite noticeable as soon as the rate is about unity, they become very important when it reaches ten. (author) [fr

  12. Overcoming the problem of residual microbial contamination in dental suction units left by conventional disinfection using novel single component suction handpieces in combination with automated flood disinfection.

    Science.gov (United States)

    Boyle, M A; O'Donnell, M J; Russell, R J; Galvin, N; Swan, J; Coleman, D C

    2015-10-01

    Decontaminating dental chair unit (DCU) suction systems in a convenient, safe and effective manner is problematic. This study aimed to identify and quantify the extent of the problems using 25 DCUs, methodically eliminate these problems and develop an efficient approach for reliable, effective, automated disinfection. DCU suction system residual contamination by environmental and human-derived bacteria was evaluated by microbiological culture following standard aspiration disinfection with a quaternary ammonium disinfectant or alternatively, a novel flooding approach to disinfection. Disinfection of multicomponent suction handpieces, assembled and disassembled, was also studied. A prototype manual and a novel automated Suction Tube Cleaning System (STCS) were developed and tested, as were novel single component suction handpieces. Standard aspiration disinfection consistently failed to decontaminate DCU suction systems effectively. Semi-confluent bacterial growth (101-500 colony forming units (CFU) per culture plate) was recovered from up to 60% of suction filter housings and from up to 19% of high and 37% of low volume suction hoses. Manual and automated flood disinfection of DCU suction systems reduced this dramatically (ranges for filter cage and high and low volume hoses of 0-22, 0-16 and 0-14CFU/plate, respectively) (P<0.0001). Multicomponent suction handpieces could not be adequately disinfected without prior removal and disassembly. Novel single component handpieces, allowed their effective disinfection in situ using the STCS, which virtually eliminated contamination from the entire suction system. Flood disinfection of DCU suction systems and single component handpieces radically improves disinfection efficacy and considerably reduces potential cross-infection and cross-contamination risks. DCU suction systems become heavily contaminated during use. Conventional disinfection does not adequately control this. Furthermore, multicomponent suction handpieces

  13. End-tidal carbon dioxide monitoring during flexible fiberoptic ...

    African Journals Online (AJOL)

    In recent years, flexible fiberoptic bronchoscopy (FFB) has been applied for diagnostic and some therapeutic purposes. During FFB and even in the presence of supplemental oxygen, hypoventilation leading to hypoxia and desaturation may occur; this is aggravated by the use of suction. Arterial oxygen saturation is usually ...

  14. Suction power output and the inertial cost of rotating the neurocranium to generate suction in fish.

    Science.gov (United States)

    Van Wassenbergh, Sam; Day, Steven W; Hernández, L Patricia; Higham, Timothy E; Skorczewski, Tyler

    2015-05-07

    To expand the buccal cavity, many suction-feeding fishes rely on a considerable contribution from dorsal rotation of the dorsal part of the head including the brains, eyes, and several bones forming the braincase and skull roof (jointly referred to as the neurocranium). As the neurocranium takes up a large part of the total mass of the head, this rotation may incur a considerable inertial cost. If so, this would suggest a significant selective pressure on the kinematics and mass distribution of the neurocranium of suction feeders. Here, an inverse dynamic model is formulated to calculate the instantaneous power required to rotate the neurocranium, approximated by a quarter ellipsoid volume of homogeneous density, as well as to calculate the instantaneous suction power based on intra-oral pressure and head volume quantifications. We applied this model to largemouth bass (Micropterus salmoides) and found that the power required to rotate the neurocranium accounts for only about 4% of the power required to suck water into the mouth. Furthermore, recovery of kinetic energy from the rotating neurocranium converted into suction work may be possible during the phase of neurocranial deceleration. Thus, we suggest that only a negligible proportion of the power output of the feeding muscles is lost as inertial costs in the largemouth bass. Consequently, the feeding performance of piscivorous suction feeders with generalised morphology, comparable to our model species, is not limited by neurocranial motion during head expansion. This suggests that it is thus not likely to be a factor of importance in the evolution of cranial shape and size. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. SWEEP Project RAT

    DEFF Research Database (Denmark)

    Ibsen, Lars Bo; Madsen, Søren; Roesen, Hanne Ravn

    In this report the design basis for the geotechnical design of the suction caisson at the K15-FA-1 location is described. The derived design soil parameters are based on the site specific CPTs conducted autumn 2010 by Wintershall Nederlands B.V. (Wintershall Netherlands B.V. and Noordhoek Survey ...

  16. Suction v. conventional curettage in incomplete abortion

    African Journals Online (AJOL)

    Suction v. conventional curettage in incomplete abortion. A randomised controlled trial. D. A. A. VERKUYL, C. A. CROWTHER .Abstract This randomised controlled trial of 357 patients who had had an incomplete abortion compared suction curettage with conventional curettage for evacuation ofthe uterus. The 179 patients ...

  17. Dielectric elastomer actuators for octopus inspired suction cups.

    Science.gov (United States)

    Follador, M; Tramacere, F; Mazzolai, B

    2014-09-25

    Suction cups are often found in nature as attachment strategy in water. Nevertheless, the application of the artificial counterpart is limited by the dimension of the actuators and their usability in wet conditions. A novel design for the development of a suction cup inspired by octopus suckers is presented. The main focus of this research was on the modelling and characterization of the actuation unit, and a first prototype of the suction cup was realized as a proof of concept. The actuation of the suction cup is based on dielectric elastomer actuators. The presented device works in a wet environment, has an integrated actuation system, and is soft. The dimensions of the artificial suction cups are comparable to proximal octopus suckers, and the attachment mechanism is similar to the biological counterpart. The design approach proposed for the actuator allows the definition of the parameters for its development and for obtaining a desired pressure in water. The fabricated actuator is able to produce up to 6 kPa of pressure in water, reaching the maximum pressure in less than 300 ms.

  18. Dielectric elastomer actuators for octopus inspired suction cups

    International Nuclear Information System (INIS)

    Follador, M; Tramacere, F; Mazzolai, B

    2014-01-01

    Suction cups are often found in nature as attachment strategy in water. Nevertheless, the application of the artificial counterpart is limited by the dimension of the actuators and their usability in wet conditions. A novel design for the development of a suction cup inspired by octopus suckers is presented. The main focus of this research was on the modelling and characterization of the actuation unit, and a first prototype of the suction cup was realized as a proof of concept. The actuation of the suction cup is based on dielectric elastomer actuators. The presented device works in a wet environment, has an integrated actuation system, and is soft. The dimensions of the artificial suction cups are comparable to proximal octopus suckers, and the attachment mechanism is similar to the biological counterpart. The design approach proposed for the actuator allows the definition of the parameters for its development and for obtaining a desired pressure in water. The fabricated actuator is able to produce up to 6 kPa of pressure in water, reaching the maximum pressure in less than 300 ms. (paper)

  19. Transformation of the fourth power block of the Chernobyl atomic power station into a ecologically safe system by a dock-caisson technological complex

    International Nuclear Information System (INIS)

    Konyukhov, S.N.; Kokulin, Eh.M.; Kozin, S.Ya.; Kurinnoj, V.N.

    1999-01-01

    The designers of the technical solution do not doubt that it is possible to transform the fourth power block of the Chernobyl APS into an ecologically safe system by help of Dock-Caisson technological complex. Application of the Dock-Caisson allows to make the operations of phases 1 and 2 of the Shelter installation transformation at the same time, i.e. to make the installation stabilization and preparation to radioactive wastes extraction simultaneously. By completion of first two phases the conditions are created for instant beginning of phase 3, i.e. disassembling of the content of the crashed power block

  20. Does the suction drain diameter matter? Bleeding analysis after total knee replacement comparing different suction drain gauges

    Directory of Open Access Journals (Sweden)

    Marcos George de Souza Leao

    Full Text Available ABSTRACT OBJECTIVES: To evaluate bleeding and the estimated blood loss in patients who underwent total knee replacement (TKR with different closed suction drains (3.2-mm and 4.8-mm gauge. METHODS: This was a randomized controlled trial with 22 patients who underwent TKR and were divided into two groups: Group I, with 11 patients in whom the 3.2-mm suction drain was used, and Group II, with 11 patients in whom the 4.8-mm suction drain was used. The hematocrit was measured after 24, 48 and 72 h after surgery in order to calculate the estimated blood loss. The drained volume was measured 3, 6, 12, 24, and 48 h after TKR, and thereafter both groups were compared. RESULTS: Regarding the hematocrit, there were no differences between groups in measured periods (24, 48, and 72 h after surgery. The total bleeding measured at the suction drains within 48 h was higher in Group II, with a statistically significant difference (p = 0.005; in the first 24 h, there was major bleeding in Group II (mean 893 mL, with a significant difference (p = 0.004. Between 24 and 48 h, there was no statistically significant difference in both groups (p = 0.710. The total estimated bleeding was higher in Group I, with mean of 463 mL, versus 409 mL in Group II, with no statistical significance (p = 0.394. CONCLUSIONS: Bleeding was higher in the group that used the 4.8 mm gauge suction drain, with no differences in hematocrit and estimated blood loss.

  1. Bottom Feeding and Beyond: How the Premaxillary Protrusion of Cypriniforms Allowed for a Novel Kind of Suction Feeding.

    Science.gov (United States)

    Hernandez, L Patricia; Staab, Katie Lynn

    2015-07-01

    While much of the functional work on suction feeding has involved members of Acanthopterygii, an earlier cypriniform radiation led to over 3200 species filling nearly every freshwater trophic niche. Within the great majority of acanthomorph clades that have been investigated suction feeding and the underlying morphology responsible for the generation of rapid suction have been largely conserved. This conserved feeding-apparatus is often associated with increasing the force experienced by the prey item, thus making a strike on elusive prey more effective. Cypriniforms' trophic anatomy is comprised of a number of novelties used for benthic feeding, which characterized early members of this clade. The modified cypriniform structure of the oral jaws represents a situation in which a particular type of suction feeding allowed for probing the benthos with a more functionally maneuverable anatomy. Requisite evolutionary modifications included origin and elongation of a median kinethmoid, duplications of certain divisions of the muscles of the adductor mandibulae, and origin of a dorsal, intra-buccal muscular palatal organ used in winnowing detritus. The elongated kinethmoid (coupled with modified adductor muscles) allowed for a type of premaxillary protrusion that decoupled the upper and lower jaws, enabled premaxillary protrusions with a closed mouth, and facilitated benthic feeding by increasing functional flexibility. The resultant flow of fluid generated by cypriniforms is also quite flexible, with multiple instances of peak flow in a single feeding event. This greatly modified morphology allowed for a degree of kinematic maneuverability not seen within most acanthomorphs. Later cypriniform radiations into piscivorous, insectivorous, or planktivorous feeding guilds were associated with shortening of the kinethmoid and with simplified morphology of the adductor, likely involving an emphasis on ram feeding. Although this suite of morphological novelties seemingly

  2. Characteristics of Wave Reflection for Vertical and Slit Caissons with Porous Structures

    Directory of Open Access Journals (Sweden)

    Tae-Hwa Jung

    2012-01-01

    Full Text Available Offshore structures are occasionally located at a relatively deep water region, the outside of breakwater. In this case, these structures may be damaged by the supposition of incident and reflected waves from a vertical breakwater. To prevent the damage, the reflected waves are controlled by installing porous structures at the face of the vertical breakwater. In this study, numerical experiments are carried out to identify the characteristics of wave reflection from the porous structures installing in front of a vertical or slit caisson.

  3. Evaluation of a flexible bronchoscope prototype designed for bronchoscopy during mechanical ventilation: a proof-of-concept study.

    Science.gov (United States)

    Nay, M-A; Auvet, A; Mankikian, J; Herve, V; Dequin, P-F; Guillon, A

    2017-06-01

    Bronchoscopy during mechanical ventilation of patients' lungs significantly affects ventilation because of partial obstruction of the tracheal tube, and may thus be omitted in the most severely ill patients. It has not previously been possible to reduce the external diameter of the bronchoscope without reducing the diameter of the suction channel, thus reducing the suctioning capacity of the device. We believed that a better-designed bronchoscope could improve the safety of bronchoscopy in patients whose lungs were ventilated. We designed a flexible bronchoscope prototype with a drumstick-shaped head consisting of a long, thin proximal portion; a short and large distal portion for camera docking; and a large suction channel throughout the length of the device. The aims of our study were to test the impact of our prototype on mechanical ventilation when inserted into the tracheal tube, and to assess suctioning capacity. We first tested the efficiency of the suction channel, and demonstrated that the suction flow of the prototype was similar to that of conventional adult bronchoscopes. We next evaluated the consequences of bronchoscopy when using the prototype on minute ventilation and intrathoracic pressures during mechanical ventilation: firstly, in vitro using a breathing simulator; and secondly, in vivo using a porcine model of pulmonary ventilation. The insertion of adult bronchoscopes into the tracheal tube immediately impaired the protective ventilation strategy employed, whereas the prototype preserved it. For the first time, we have developed an innovative flexible bronchoscope designed for bronchoscopy during invasive mechanical ventilation, that both preserved the protective ventilation strategy, and enabled efficient suction flow. © 2017 The Association of Anaesthetists of Great Britain and Ireland.

  4. Aseptic necrosis in caisson workers: a new set of decompression tables.

    Science.gov (United States)

    Downs, G J; Kindwall, E P

    1986-06-01

    There is a high incidence of aseptic necrosis and decompression sickness among caisson workers due to inadequate decompression using the current OSHA decompression tables (1-7). Because of this, a new set of tables--Autodec III-O2--was developed which more effectively eliminates nitrogen from the body and, therefore, should decrease the incidence of both bends and aseptic necrosis. The Autodec III-O2 schedule's superiority was statistically significant at a level of 0.08 compared to the OSHA table. It is our conclusion that OSHA should adopt the Autodec III-O2 schedule as a replacement for the current decompression tables.

  5. Advances on development of suction and temperature controlled oedometer cell

    International Nuclear Information System (INIS)

    Ye Weimin; Zhang Yawei; Chen Bao; Wang Min

    2010-01-01

    Oedometer cells for unsaturated soils can be classified into two types, that is, conventional unsaturated oedometer cells (high-suction unsaturated oedometer cell, high-suction and high-pressure unsaturated oedometer cell) and temperature controlled unsaturated oedometer cells. Among them, the osmotic, vapor equilibrium and axis translation techniques are often employed for suction control. The thermostat bath method and thermostatically controlled heater method are commonly used for temperature control. The lever loading system, hydraulic loading system and air pressure loading system are commonly means used for vertical pressure. Combination of osmotic (or axis translation) technique with vapor equilibrium method employed for the full range suction control, thermostatically liquid temperature control method, and the hydraulic loading system, could be used for suction, temperature and loading control in the design for unsaturated oedometer cells in the future, which can be used for study of buffer/backfill materials under high-temperature, high pressure and full range suction conditions. (authors)

  6. Scintigraphy versus radiography in the early diagnosis of experimental bone necrosis with special reference to caisson disease of bone

    International Nuclear Information System (INIS)

    Gregg, P.J.; Walder, D.N.

    1980-01-01

    The early diagnosis of caisson disease of bone is hindered by the long delay which must elapse before an abnormality becomes apparent on a radiograph. The possible use of bone scintigraphy for this purpose was investigated. Necrosis of the bone and marrow was produced in rabbits by glass microspheres to simulate persistent gas-bubble emboli and then serial radiographs and scintigrams using sup(99m)Tc-diphosphonate were obtained. Regions of necrosis could be detected as 'hot spots' on the scintigrams as early as three weeks after the causative insult, which was many weeks before any abnormality could be detected on the radiographs. Histological examination of excised femora suggested that the scintigraphic abnormality might depend on the new bone formation established during a reactive or repair process. It is suggested that scintigraphy may have clinical value in caisson disease. (author)

  7. Scintigraphy versus radiography in the early diagnosis of experimental bone necrosis, with special reference to caisson disease of bone.

    Science.gov (United States)

    Gregg, P J; Walder, D N

    1980-05-01

    The early diagnosis of caisson disease of bone is hindered by the long delay which must elapse before an abnormality becomes apparent on a radiograph. The possible use of bone scintigraphy for this purpose was investigated. Necrosis of the bone and marrow was produced in rabbits by glass microspheres to simulate persistent gas-bubble emboli and then serial radiographs and scintigrams using 99mTc-diphosphonate were obtained. Regions of necrosis could be detected as "hot-spots" on the scintigrams as early as three weeks after the causative insult, which was many weeks before any abnormality could be detected on the radiographs. Histological examination of excised femora suggested that the scintigraphic abnormality might depend on the new bone formation during a reactive or repair process. It is suggested that scintigraphy may have clinical value in caisson disease.

  8. Investigation of suction anchor pullout capacity under undrained conditions

    OpenAIRE

    Jarand, Pollestad

    2015-01-01

    Master's thesis in Offshore technology Floating units are dependent on reliable mooring systems to ensure safety during marine operations. Suction anchors have proved to be a technologically viable and cost-effective concept. They are capable of precision installation, re-use, and provide large resistive capacity. This thesis investigates load capacity and failure modes of suction anchors subjected to vertical, horizontal (lateral), and incline loading. Suction anchor design co...

  9. Enhanced effect of suction-cavitation on the ozonation of phenol

    International Nuclear Information System (INIS)

    Wu Zhilin; Franke, Marcus; Ondruschka, Bernd; Zhang, Yongchun; Ren Yanze; Braeutigam, Patrick; Wang, Weimin

    2011-01-01

    800 mL of 1.0 mM phenol-containing aqueous solution was circulated at 20 ° C for 30 min in a suction-reactor, while 3.2 mg min -1 ozone was introduced into the solution under the suction orifice. The removal rates of phenol vary polynomially with the orifice diameter as well as the suction pressure. The rate constant for the zero-order kinetics achieves the highest value at -0.070 MPa by using 5 mm orifice. Although the suction-cavitation alone cannot remove phenol in 30 min, it can considerably enhance the ozonation of phenol. The rate constants for the zero-order kinetics by the simple ozonation and the combined method are 0.018 and 0.028 min -1 , respectively. Furthermore, no ozone was observed in the tail gas during the first 15 min for the ozonation in the suction reactor, and then the concentration of unreacted ozone slowly increased, indicating that the utilization rate of ozone is significantly improved by the suction-cavitation. The increasing input concentration of ozone obviously accelerates the ozonation of phenol, but the total required quantities of ozone are very close by various ozone input concentrations to reach the same degradation rate, indicating the ozonation assisted by the suction-cavitation can be considered as a quantitative reaction.

  10. Wave Forces on Transition Pieces for Bucket Foundations for Offshore Wind Turbines

    DEFF Research Database (Denmark)

    Nezhentseva, Anastasia; Andersen, Thomas Lykke; Andersen, Lars Vabbersgaard

    to a bucket foundation (suction caisson) located at 35 m water depth in the North Sea. Several models of the TPs (wedge-shaped steel flange-reinforced shear panels, conical and doubly curved with or without cutaways) are tested in a wave flume and compared with respect to wave loading. Due to a larger size...

  11. Numerical simulation and experimental investigation on suction heating of a BOG compressor

    International Nuclear Information System (INIS)

    Jia, Xiaohan; Zhao, Bin; Feng, Jianmei; Zheng, Sulu; Peng, Xueyuan

    2016-01-01

    Highlights: • An investigation focusing on suction heating of a BOG compressor is carried out. • There is frost on the cylinder cover as the compressor at lower suction temperature. • The suction and discharge flow rate decrease with rising suction temperature. • The volumetric efficiency has a maximum value with increasing suction temperature. • The temperature coefficient increased with suction temperature or rotational speed. - Abstract: One of the key components of a liquefied natural gas (LNG) receiving terminal is the boil-off gas (BOG) compressor, which is used to pump out the BOG from the LNG storage tank to ensure safety in the transportation and receiving systems. Owing to the ultra-low suction temperature, the heat exchange between the intake gas and the cylinder, piston, and cylinder cover cannot be ignored as in normal conditions. This paper presents an investigation focusing on suction heating of the BOG compressor. A finite element model with dynamic mesh was established to simulate the suction process. At the same time, a performance test rig was built to study the characteristics of the BOG compressor under low suction temperature conditions and verify the numerical model. Consequently, the results of the simulation were in good agreement with experimental results. Both results implied that the temperature of cylinder surface increased starting from the cylinder cover to the crankcase. In addition, at lower suction temperature, the temperature difference between various points on the cylinder surface and cylinder cover was much larger than that at higher suction temperature. With increasing suction temperature, the temperature coefficient increased markedly, and the difference between gas temperatures at the beginning and end of the suction process, as well as the compressor flow rate, decreased significantly; however, the volumetric efficiency increased first and then decreased. Furthermore, the temperature coefficient clearly increased

  12. Robotic Hand with Flexible Fingers for Grasping Cylindrical Objects

    OpenAIRE

    柴田, 瑞穂

    2015-01-01

    In this manuscript, a robotic hand for grasping a cylindrical object is proposed. This robotic hand has flexible fingers that can hold a cylindrical object during moving. We introduce a grasping strategy for a cylindrical object in terms of state transition graph. In this strategy the robotic hand picks up the cylindrical object utilizing a suction device before the hand grasp the object. We also design the flexible fingers; then, we investigate the validity of this robotic hand via several e...

  13. A study on dysbaric osteonecrosis in caisson workers.

    Science.gov (United States)

    Kuang, X Y; Chen, L J; Li, H L; Yao, F; Xu, J M; Huang, F; Guo, L J

    2014-01-01

    To study the effects of exposure to compressed air on tunnel workers' health and to investigate the prevalence of dysbaric osteonecrosis (DON) in caisson workers. 128 tunnel workers were divided into the exposed group (n = 58) and the control group (n = 70), and their shoulders, hips and knees were examined with X-ray, computed tomography (CT) and magnetic resonance imaging (MRI). 1) 34.5% of the exposed group were diagnosed with DON based on the national diagnostic criteria of decompression sickness. 2) The incidental difference of skeletal cystic changes between the exposed group and the control group was highly statistically significant (p < 0.01). 3) CT and MRI examination could detect early onset of DON lesions, and the cystic changes shown in CT and abnormal signals in MRI were diagnostic indicators in cases. Cystic changes in CT and abnormal signals in MRI are key imaging findings of early DON.

  14. On equations for the total suction and its matric and osmotic components

    International Nuclear Information System (INIS)

    Dao, Vinh N.T.; Morris, Peter H.; Dux, Peter F.

    2008-01-01

    A clear fundamental understanding of suctions is crucial for the study of the behaviour of plastic cement mortar and concrete, including plastic shrinkage cracking. In this paper, the expression relating the change in free energy of the pore water with an isothermal change in pressure is first derived. Based upon definitions of suctions, it is then shown that total, matric, and osmotic suctions can all be expressed in the same thermodynamic form. The widely accepted, but not yet satisfactorily validated, assumption that the total suction comprises matric and osmotic components is then confirmed theoretically. The well-known Kelvin equation for matric suction, and Morse and van't Hoff equations for osmotic suction are subsequently derived from the corresponding thermodynamic equations. The applicability of latter two equations in evaluating the osmotic suctions of cement mortar and concrete is highlighted

  15. Suction v. conventional curettage in incomplete abortion A ...

    African Journals Online (AJOL)

    This randomised controlled trial of 357 patients who had had an incomplete abortion compared suction curettage with conventional curettage for evacuation ofthe uterus. The 179 patients undergoing suction curettage had a significantly lower intra-operative blood loss (P < 0,0001) and a significantly higher mean ...

  16. Octopus-like suction cups: from natural to artificial solutions.

    Science.gov (United States)

    Tramacere, F; Follador, M; Pugno, N M; Mazzolai, B

    2015-05-13

    Octopus suckers are able to attach to all nonporous surfaces and generate a very strong attachment force. The well-known attachment features of this animal result from the softness of the sucker tissues and the surface morphology of the portion of the sucker that is in contact with objects or substrates. Unlike artificial suction cups, octopus suckers are characterized by a series of radial grooves that increase the area subjected to pressure reduction during attachment. In this study, we constructed artificial suction cups with different surface geometries and tested their attachment performances using a pull-off setup. First, smooth suction cups were obtained for casting; then, sucker surfaces were engraved with a laser cutter. As expected, for all the tested cases, the engraving treatment enhanced the attachment performance of the elastomeric suction cups compared with that of the smooth versions. Moreover, the results indicated that the surface geometry with the best attachment performance was the geometry most similar to octopus sucker morphology. The results obtained in this work can be utilized to design artificial suction cups with higher wet attachment performance.

  17. Comparison the Effects of Shallow and Deep Endotracheal Tube Suctioning on Respiratory Rate, Arterial Blood Oxygen Saturation and Number of Suctioning in Patients Hospitalized in the Intensive Care Unit: A Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Mohammad Abbasinia

    2014-09-01

    Full Text Available Introduction: Endotracheal tube suctioning is essential for improve oxygenation in the patients undergoing mechanical ventilation. There are two types of shallow and deep endotracheal tube suctioning. This study aimed to evaluate the effect of shallow and deep suctioning methods on respiratory rate (RR, arterial blood oxygen saturation (SpO2 and number of suctioning in patients hospitalized in the intensive care units of Al-Zahra Hospital, Isfahan, Iran. Methods: In this randomized controlled trial, 74 patients who hospitalized in the intensive care units of Isfahan Al-Zahra Hospital were randomly allocated to the shallow and deep suctioning groups. RR and SpO2 were measured immediately before, immediately after, 1 and 3 minute after each suctioning. Number of suctioning was also noted in each groups. Data were analyzed using repeated measures analysis of variance (RMANOVA, chi-square and independent t-tests. Results: RR was significantly increased and SpO2 was significantly decreased after each suctioning in the both groups. However, these changes were not significant between the two groups. The numbers of suctioning was significantly higher in the shallow suctioning group than in the deep suctioning group. Conclusion: Shallow and deep suctioning had a similar effect on RR and SpO2. However, shallow suctioning caused further manipulation of patient’s trachea than deep suctioning method. Therefore, it seems that deep endotracheal tube suctioning method can be used to clean the airway with lesser manipulation of the trachea.

  18. Comparison the effects of shallow and deep endotracheal tube suctioning on respiratory rate, arterial blood oxygen saturation and number of suctioning in patients hospitalized in the intensive care unit: a randomized controlled trial.

    Science.gov (United States)

    Abbasinia, Mohammad; Irajpour, Alireza; Babaii, Atye; Shamali, Mehdi; Vahdatnezhad, Jahanbakhsh

    2014-09-01

    Endotracheal tube suctioning is essential for improve oxygenation in the patients undergoing mechanical ventilation. There are two types of shallow and deep endotracheal tube suctioning. This study aimed to evaluate the effect of shallow and deep suctioning methods on respiratory rate (RR), arterial blood oxygen saturation (SpO2) and number of suctioning in patients hospitalized in the intensive care units of Al-Zahra Hospital, Isfahan, Iran. In this randomized controlled trial, 74 patients who hospitalized in the intensive care units of Isfahan Al-Zahra Hospital were randomly allocated to the shallow and deep suctioning groups. RR and SpO2 were measured immediately before, immediately after, 1 and 3 minute after each suctioning. Number of suctioning was also noted in each groups. Data were analyzed using repeated measures analysis of variance (RMANOVA), chi-square and independent t-tests. RR was significantly increased and SpO2 was significantly decreased after each suctioning in the both groups. However, these changes were not significant between the two groups. The numbers of suctioning was significantly higher in the shallow suctioning group than in the deep suctioning group. Conclusion : Shallow and deep suctioning had a similar effect on RR and SpO2. However, shallow suctioning caused further manipulation of patient's trachea than deep suctioning method. Therefore, it seems that deep endotracheal tube suctioning method can be used to clean the airway with lesser manipulation of the trachea.

  19. Development of standard practice guidelines for open and closed system suctioning.

    Science.gov (United States)

    Özden, Dilek; Görgülü, R Selma

    2012-05-01

    This study was carried out to determine the knowledge and practice of nurses before and after training and the development of standard practice guidelines for open and closed system suctioning methods in patients with endotracheal tubes. Many life-threatening complications can occur when a suctioning procedure is not performed with the correct technique. It has been reported that standard practice guidelines for suctioning are insufficient in clinical practice. Non-participant structured observational study. We assessed a total of 48 nurses who were employed in the cardiovascular surgery intensive care unit of a state hospital in Turkey. We used a questionnaire and nurse observation forms to assess the use of the open and closed system suctioning. There was a significant difference between the mean scores of the answers ('true', 'wrong' and 'I do not know') for the use of open and closed system suctioning before and after training. In addition, all steps of both suctioning procedures were carried out correctly during the third observation. The compliance of the nurses to the standard practice guidelines for open and closed suctioning and their knowledge levels on the subject were increased after training, while the implementation of standards was satisfactory. The development of open and closed system suctioning standard practice guidelines directly contributed to the enhancement of patient safety and the quality of nursing care. It is suggested that, as in other nursing care practices, suctioning should be carried out in accordance with standard practice guidelines, and health institutions should develop their standard practice guidelines and work in accordance with them. © 2012 Blackwell Publishing Ltd.

  20. Study on seismic stability of seawall in man-made island. Pt. 3. Development of evaluation method for seismic stability of seawall considering dynamic interaction of armour embankment and caisson

    International Nuclear Information System (INIS)

    Tochigi, Hitoshi; Kanatani, Mamoru; Kawai, Tadashi

    1999-01-01

    In the development of siting technology for off-shore nuclear power plants on man-made island, assessing the stability of seawall which ensure the safety of backfill ground against ocean waves and earthquakes is indispensable. Concerning the seismic stability of seawall, it is indicated that the evaluation of the influence of lateral pressure of armour embankment acting on the caisson wall is an important factor. We proposed modeling method of discontinuity such as armour unit by distinct element method (DEM) and combined them with caisson type seawall model idealized by FEM. To show the validity of this DEM-FEM hybrid analysis method, the numerical simulation for the shaking table tests was conducted. For the two kinds of seawall model with armour embankment and without the one, the lateral displacement of the seawall induced by sliding of caisson is successfully reproduced and accuracy of above mentioned numerical procedure is confirmed. (author)

  1. Barodontalgias, dental and orofacial barotraumas: a survey in Swiss divers and caisson workers.

    Science.gov (United States)

    Zanotta, Cristina; Dagassan-Berndt, Dorothea; Nussberger, Peter; Waltimo, Tuomas; Filippi, Andreas

    2014-01-01

    Changing ambient pressure can lead to medical conditions in body cavities filled with air. Intraoral pain elicited by changes in pressure is referred to as barodontalgia. Dental barotraumas are defined as pressure-induced damages of teeth and restorations. The pathophysiologic background so far is not completely clear. The present study deals with dental and orofacial symptoms which can occur as a result of pressure variations. With the aid of cantonal administrations, diving associations, and tunnel construction firms, 520 pressure-exposed individuals (499 scuba/ professional divers, 21 caisson workers operating at excess pressure) were questioned regarding dental problems. A personal interview was conducted with affected individuals. Problems in the dental area were experienced by 15% of all respondents. Toothaches were suffered by 10.2% of the participants. Tooth injuries occurred in 6.3% of all interviewees (26 fractured amalgam restorations, 4 crown fractures, 3 losses of tooth fragments). A proportion of 11.3% among the respondents complained about temporomandibular joint problems or mucosal irritations (for example aphthae) related to the mouthpieces. Barotraumas outside the dental area were incurred by 31.9% of the divers. Of these, 69.9% concerned the ears and 65.6% occurred during the descent. Based on the results obtained from the survey and taking into account the current literature, recommendations for the prevention of barotraumas in divers and caisson workers were prepared. Diagnostic exclusion of dental pathologies and avoidance of retentive reconstruction materials are important factors for the prevention of barodontalgias and dental barotraumas.

  2. Suction generation in white-spotted bamboo sharks Chiloscyllium plagiosum.

    Science.gov (United States)

    Wilga, Cheryl D; Sanford, Christopher P

    2008-10-01

    After the divergence of chondrichthyans and teleostomes, the structure of the feeding apparatus also diverged leading to alterations in the suction mechanism. In this study we investigated the mechanism for suction generation during feeding in white-spotted bamboo sharks, Chiloscyllium plagiosum and compared it with that in teleosts. The internal movement of cranial elements and pressure in the buccal, hyoid and pharyngeal cavities that are directly responsible for suction generation was quantified using sonomicrometry and pressure transducers. Backward stepwise multiple linear regressions were used to explore the relationship between expansion and pressure, accounting for 60-96% of the variation in pressure among capture events. The progression of anterior to posterior expansion in the buccal, hyoid and pharyngeal cavities is accompanied by the sequential onset of subambient pressure in these cavities as prey is drawn into the mouth. Gape opening triggers the onset of subambient pressure in the oropharyngeal cavities. Peak gape area coincides with peak subambient buccal pressure. Increased velocity of hyoid area expansion is primarily responsible for generating peak subambient pressure in the buccal and hyoid regions. Pharyngeal expansion appears to function as a sink to receive water influx from the mouth, much like that of compensatory suction in bidirectional aquatic feeders. Interestingly, C. plagiosum generates large suction pressures while paradoxically compressing the buccal cavity laterally, delaying the time to peak pressure. This represents a fundamental difference from the mechanism used to generate suction in teleost fishes. Interestingly, pressure in the three cavities peaks in the posterior to anterior direction. The complex shape changes that the buccal cavity undergoes indicate that, as in teleosts, unsteady flow predominates during suction feeding. Several kinematic variables function together, with great variation over long gape cycles to

  3. Massive aspiration past the tracheal tube cuff caused by closed tracheal suction system.

    Science.gov (United States)

    Dave, Mital H; Frotzler, Angela; Madjdpour, Caveh; Koepfer, Nelly; Weiss, Markus

    2011-01-01

    Aspiration past the tracheal tube cuff has been recognized to be a risk factor for the development of ventilator-associated pneumonia (VAP). This study investigated the effect of closed tracheal suctioning on aspiration of fluid past the tracheal tube cuff in an in vitro benchtop model. High-volume low pressure tube cuffs of 7.5 mm internal diameter (ID) were placed in a 22 mm ID artificial trachea connected to a test lung. Positive pressure ventilation (PPV) with 15 cm H₂O peak inspiratory pressure and 5 cm H₂O positive end-expiratory pressure (PEEP) was used. A closed tracheal suction system (CTSS) catheter (size 14Fr) was attached to the tracheal tube and suction was performed for 5, 10, 15, or 20 seconds under 200 or 300 cm H₂O suction pressures. Amount of fluid (mL) aspirated along the tube cuff and the airway pressure changes were recorded for each suction procedure. Fluid aspiration during different suction conditions was compared using Kruskal-Wallis and Mann-Whitney test (Bonferroni correction [α = .01]). During 10, 15, and 20 seconds suction, airway pressure consistently dropped down to -8 to -13 cm H₂O (P aspiration was never observed under PPV + PEEP but occurred always during suctioning. Aspiration along the tube cuff was higher with -300 cm H₂O than with -200 cm H₂O suction pressure (P aspiration of fluid occurs along the tracheal tube cuff during suction with the closed tracheal suction system. © SAGE Publications 2011.

  4. Large Scale Experiments on the Interaction of a Caisson Breakwater with Breaking Waves

    DEFF Research Database (Denmark)

    Stagonas, Dimitris; Marzeddu, Andrea; Buccino, Mariano

    2014-01-01

    waves, which resulted in impulsive conditions at the face of the caisson. Amongst our objectives was to look at the mechanisms occurring when a wave breaks at the structure and to investigate the validity of tactile pressure sensors. As such, for all experiments, pressure, force and surface elevation...... measurements were complimented with high speed and high definition video records. ln addition, a pressure mapping system employing tactile pressure sensors was deployed in cornbination with force panels, both positioned at still water level. Although at a very early stage, data analysis yields promising...

  5. Cavitation simulation and NPSH prediction of a double suction centrifugal pump

    International Nuclear Information System (INIS)

    Li, P; Huang, Y F; Li, J

    2012-01-01

    This paper illustrates the flow field numerical analysis of the double-suction centrifugal pump. For the study of the cavitation flow inside the double-suction centrifugal pump, the professional pump/motor simulation software PumpLinx and its Full Cavitation Model has been employed. According to the PumpLinx calculation result and the Cavitation damage index, the cavitation position, level and the cavitation characteristics of the double-suction centrifugal pump has been predicted. For the further objective, the simulation of the flow field in the double-suction centrifugal pump under different inlet conditions has been carried out. By the result analysis, NPSHr has been predicted; the reliability of the results has been verified by comparing with the experimental data. At the same time, this practice can provide guidance for the optimal design of double-suction pump.

  6. Seepage Study for Suction Installation of Bucket Foundation in Different Soil Combinations

    DEFF Research Database (Denmark)

    Koteras, Aleksandra Katarzyna; Ibsen, Lars Bo; Clausen, Johan Christian

    2016-01-01

    Research has proven the bucket foundation to be a feasible and an attractive solution for offshore wind turbines. Its potential derives partly from the cost-effectiveness due to the suction-assisted installation. The suction applied under the bucket lid produces a downward driving force and addit......Research has proven the bucket foundation to be a feasible and an attractive solution for offshore wind turbines. Its potential derives partly from the cost-effectiveness due to the suction-assisted installation. The suction applied under the bucket lid produces a downward driving force...... around the bucket skirt. The exceedance of critical suction might lead to installation failure due to formation of piping channels, which break the hydraulic seal between the skirt and soil. The excess pore pressure arising due to applied suction changes the effective stress, hence the penetration...

  7. Bio-inspired Miniature Suction Cups Actuated by Shape Memory Alloy

    Directory of Open Access Journals (Sweden)

    Hu Bing-shan

    2010-02-01

    Full Text Available Wall climbing robots using negative pressure suction always employ air pumps which have great noise and large volume. Two prototypes of bio-inspired miniature suction cup actuated by shape memory alloy (SMA are designed based on studying characteristics of biologic suction apparatuses, and the suction cups in this paper can be used as adhesion mechanisms for miniature wall climbing robots without air pumps. The first prototype with a two-way shape memory effect (TWSME extension TiNi spring imitates the piston structure of the stalked sucker; the second one actuated by a one way SMA actuator with a bias has a basic structure of stiff margin, guiding element, leader and elastic element. Analytical model of the second prototype is founded considering the constitutive model of the SMA actuator, the deflection of the thin elastic plate under compound load and the thermo-dynamic model of the sealed air cavity. Experiments are done to test their suction characteristics, and the analytical model of the second prototype is simulated on Matlab/simulink platform and validated by experiments.

  8. Bio-inspired Miniature Suction Cups Actuated by Shape Memory Alloy

    Directory of Open Access Journals (Sweden)

    Hu Bing-Shan

    2009-09-01

    Full Text Available Wall climbing robots using negative pressure suction always employ air pumps which have great noise and large volume. Two prototypes of bio-inspired miniature suction cup actuated by shape memory alloy (SMA are designed based on studying characteristics of biologic suction apparatuses, and the suction cups in this paper can be used as adhesion mechanisms for miniature wall climbing robots without air pumps. The first prototype with a two-way shape memory effect (TWSME extension TiNi spring imitates the piston structure of the stalked sucker; the second one actuated by a one way SMA actuator with a bias has a basic structure of stiff margin, guiding element, leader and elastic element. Analytical model of the second prototype is founded considering the constitutive model of the SMA actuator, the deflection of the thin elastic plate under compound load and the thermo-dynamic model of the sealed air cavity. Experiments are done to test their suction characteristics, and the analytical model of the second prototype is simulated on Matlab/simulink platform and validated by experiments.

  9. Effects of shallow and deep endotracheal tube suctioning on cardiovascular indices in patients in intensive care units.

    Science.gov (United States)

    Irajpour, Alireza; Abbasinia, Mohammad; Hoseini, Abbas; Kashefi, Parviz

    2014-07-01

    Clearing the endotracheal tube through suctioning should be done to promote oxygenation. Depth of suctioning is one of the variables in this regard. In shallow suctioning method, the catheter passes to the tip of the endotracheal tube, and in deep suctioning method, it passes beyond the tip into the trachea or brunches. This study aimed to evaluate the effect of shallow and deep suctioning methods on cardiovascular indices in patients hospitalized in the intensive care units (ICUs). In this clinical trial, 74 patients were selected among those who had undergone mechanical ventilation in the ICU of Al-Zahra Hospital, Isfahan, Iran using convenience sampling method. The subjects were randomly allocated to shallow and deep suctioning groups. Heart rate (HR) and blood pressure (BP) were measured immediately before and 1, 2, and 3 min after each suctioning. Number of times of suctioning was also noted in both the groups. Data were analyzed using repeated measures analysis of variance (ANOVA), Chi-square and independent t-tests. HR and BP were significantly increased after suctioning in both the groups (P 0.05). The suctioning count was significantly higher in the shallow suctioning group than in the deep suctioning group. Shallow and deep suctioning were similar in their effects on HR and BP, but shallow suctioning caused further manipulation of patient's trachea than deep suctioning method. Therefore, in order to prevent complications, nurses are recommended to perform the endotracheal tube suctioning by the deep method.

  10. Behaviour of a pre-stressed concrete pressure-vessel subjected to a high temperature gradient; Comportement d'un caisson en beton precontraint soumis a un gradient de temperature eleve

    Energy Technology Data Exchange (ETDEWEB)

    Dubois, F [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires; Bonvalet, Ch; Dawance, G; Marechal, J C [Centre Experimental de Recherches et d' Etudes du Batiment et des Travaux Publics (CEBTP), 76 - Harfleur (France)

    1965-07-01

    possible both to draw up a programme for future tests and to propose a calculation model for pre-stressed concrete pressure-vessels. (authors) [French] Apres avoir rappele les problemes poses par les caissons pour les reacteurs atomiques (formes des caissons, pressions, ouvertures, fondations, etc.), on expose l'interet presente par les caissons en beton precontraint, par rapport aux caissons en acier. Toutefois, l'utilisation des caissons en beton precontraint souleve de nombreuses difficultes liees aux proprietes des betons. Ainsi, faute de connaissances approfondies du materiau, il est necessaire de placer une peau d'etancheite en acier contre le beton, d'avoir un isolant thermique ou un circuit de refroidissement pour limiter les deformations et les contraintes, etc. Par suite, l'etude du comportement du beton precontraint et du caisson soumis a un gradient eleve de temperature peut apporter des informations utiles. Une maquette au l/10eme d'un caisson cylindrique en beton precontraint sans fond ni ouverture laterale, a ete realisee. Avant de decrire les essais effectues, quelques considerations theoriques sont developpees concernant les conditions de similitude 'modele reduit - ouvrage reel' et le calcul des sollicitations thermiques et mecaniques. La maquette de caisson en beton precontraint etait chauffee interieurement par un element de pyrotenax et refroidie exterieurement par un violent courant d'air. Le beton etait precontraint par des cables horizontaux et verticaux a 80 kg/cm{sup 2}; le gradient thermique atteignait 160 deg. C, Les deformations globales et locales, la variation de la teneur en eau, le module d'elasticite, la tension et le fluage des cables, la profondeur des fissures ont ete mesures au cours des differents essais. Les deformations globales observees sont compatibles avec les theories des deformations thermiques et le fluage des cables a atteint 20 a 30 pour cent suivant leur position par rapport a la surface interieure. Le module d

  11. Spinal cord electrophysiology II: extracellular suction electrode fabrication.

    Science.gov (United States)

    Garudadri, Suresh; Gallarda, Benjamin; Pfaff, Samuel; Alaynick, William

    2011-02-20

    Development of neural circuitries and locomotion can be studied using neonatal rodent spinal cord central pattern generator (CPG) behavior. We demonstrate a method to fabricate suction electrodes that are used to examine CPG activity, or fictive locomotion, in dissected rodent spinal cords. The rodent spinal cords are placed in artificial cerebrospinal fluid and the ventral roots are drawn into the suction electrode. The electrode is constructed by modifying a commercially available suction electrode. A heavier silver wire is used instead of the standard wire given by the commercially available electrode. The glass tip on the commercial electrode is replaced with a plastic tip for increased durability. We prepare hand drawn electrodes and electrodes made from specific sizes of tubing, allowing consistency and reproducibility. Data is collected using an amplifier and neurogram acquisition software. Recordings are performed on an air table within a Faraday cage to prevent mechanical and electrical interference, respectively.

  12. Water born pollutants sampling using porous suction samples

    International Nuclear Information System (INIS)

    Baig, M.A.

    1997-01-01

    The common standard method of sampling water born pollutants in the vadoze zone is core sampling and it is followed by extraction of pore fluid. This method does not allow sampling at the same location next time and again later on. There is an alternative approach for sampling fluids (water born pollutants) from both saturated and unsaturated regions of vadose zone using porous suction samplers. There are three types of porous suction samplers, vacuum-operated, pressure-vacuum lysimeters, high pressure vacuum samples. The suction samples are operated in the range of 0-70 centi bars and usually consist of ceramic and polytetrafluorethylene (PTFE). The operation range of PTFE is higher than ceramic cups. These samplers are well suited for in situ and repeated sampling form the same location. This paper discusses the physical properties and operating condition of such samplers to the utilized under our environmental sampling. (author)

  13. Effect of suction on the mechanical characteristics of uniformly compacted rammed earth

    Science.gov (United States)

    El Hajjar, A.; Chauhan, P.; Prime, N.; Plé, O.

    2018-04-01

    Rammed earth, in the current environmental situation, is an alternative construction technique which can help in reducing energy and raw material consumption owing to its “sustainable” characteristics. To fully understand its behavior and properties, recent scientific investigations consider it as a compacted unsaturated material with suction as its one of the main sources of strength. Eathern constructions face, over their lifetime, variations in the suction state which have a significant impact on their mechanical characteristics. In the present contribution, unconfined compression tests are performed, with and without unload-reload cycles, on homogeneously compacted samples subjected to various suction conditions. This study shows that both the unconfined compressive strength and Young modulus reduce with the reduction of suction states. Suction also seems to influence the amount of plastic strains and damage phenomenon. Indeed, the soils analyzed are slightly active and shows both plasticity behavior and damage phenomenon.

  14. Deep versus shallow suction of endotracheal tubes in ventilated neonates and young infants.

    Science.gov (United States)

    Gillies, Donna; Spence, Kaye

    2011-07-06

    Mechanical ventilation is commonly used in Neonatal Intensive Care Units to assist breathing in a variety of conditions. Mechanical ventilation is achieved through the placement of an endotracheal tube (ETT) which is left in-situ. The ETT is suctioned to prevent a build-up of secretions and blockage of the airway. Methods of suctioning the endotracheal tube vary according to institutional practice and the individual clinician performing the task. The depth of suctioning is one of these variables. The catheter may be passed to the tip of the ETT or beyond the tip into the trachea or bronchi to facilitate removal of secretions. However, trauma to the lower airways may result from the suction catheter being passed into the airway beyond the tip of the endotracheal tube. To compare the effectiveness and complications of deep (catheter passed beyond the tip of the ETT) versus shallow (catheter passed to length of ETT only) suctioning of the endotracheal tube in ventilated infants. In this first update the searches were expanded to the Cochrane Central Register of Controlled Trials (The Cochrane Library, March 30), MEDLINE (from January 1966 to May 30 2011), CINAHL (from 1982 to May 30 2011) and EMBASE (1980 to May 2011) using text words and subject headings relevant to endotracheal suctioning. There were no language restrictions. Controlled trials using random or quasi-random allocation of neonates receiving ventilatory support via an endotracheal tube to either deep or shallow endotracheal suctioning. The updated search resulted in 149 potentially relevant references. Two of the studies from this search were identified as potentially relevant. We included one of the potentially relevant studies and the other was excluded because it did not fit the inclusion criteria. One small crossover trial (n = 27) of shallow versus deep suctioning met the criteria for inclusion in this review. The reported outcomes were oxygen saturation and heart rate, during and after suctioning

  15. [Bone and joint changes due to compressed air in divers and Caisson workers (author's transl)].

    Science.gov (United States)

    Poser, H; Gabriel-Jürgens, P

    1977-02-01

    The radiological and morphological changes of Caisson disease in the skeleton are well known. The findings of interest to radiologists are described. Because of its position, its was possible to review a large number of divers in Kiel; these have been under observation for years, and even decades. The development, manifestation and course of chronic skeletal changes due to compressed air are described to compressed air are described and, according to severity, are classified into types 1 to 4. Late changes are discussed in detail, since these are of importance in relation to compensation.

  16. Vortex lift augmentation by suction on a 60 deg swept Gothic wing

    Science.gov (United States)

    Taylor, A. H.; Jackson, L. R.; Huffman, J. K.

    1982-01-01

    An experimental investigation was conducted in the Langley high-speed 7- by 10-foot wind tunnel to determine the aerodynamic performance of suction applied near the wing tips above the trailing edge of a 60 deg swept Gothic wing. Moveable suction inlets were symmetrically mounted in the proximity of the trailing edge, and the amount of suction was varied to maximize wing lift. Tests were conducted at Mach 0.15, 0.30, and 0.45, and the angle of attack was varied from -4 to 50 deg. The suction augmentation increases the lift coefficient over the entire range of angle of attack. The lift improvement exceeds the unaugmented wing lift by over 20%. Moreover, the augmented lift exceeds the lift predicted by vortex lattice theory to 30 deg angle of attack. Suction augmentation is postulated to strengthen the vortex system by increasing its velocity and making it more concentrated. This causes the vortex breakdown to be delayed to a higher angle of attack

  17. Evaluation of Karl Storz CMAC TipTM Device Versus Traditional Airway Suction in a Cadaver Model

    Directory of Open Access Journals (Sweden)

    Demis N. Lipe

    2014-07-01

    Full Text Available Introduction: We compared the efficacy of Karl Storz CMAC TipTM with inline suction to CMAC with traditional suction device in cadaveric models simulating difficult airways, using media mimicking pulmonary edema and vomit. Methods: This was a prospective, cohort study in which we invited emergency medicine faculty and residents to participate. Each participant intubated 2 cadavers (one with simulated pulmonary edema and one with simulated vomit, using CMAC with inline suction and CMAC with traditional suction. Thirty emergency medicine providers performed 4 total intubations each in a crossover trial comparing the CMAC with inline suction and CMAC with traditional suction. Two intubations were performed with simulated vomit and two with simulated pulmonary edema. The primary outcome was time to successful intubation; and the secondary outcome was proportion of successful intubation. Results: The median time to successful intubation using the CMAC with inline suction versus traditional suction in the pulmonary edema group was 29s and 30s respectively (p=0.54. In the vomit simulation, the median time to successful intubation was 40s using the CMAC with inline suction and 41s using the CMAC with traditional suction (p=0.70. There were no significant differences in time to successful intubation between the 2 devices. Similarly, the proportions of successful intubation were also not statistically significant between the 2 devices. The proportions of successful intubations using the inline suction were 96.7% and 73.3%, for the pulmonary edema and vomit groups, respectively. Additionally using the handheld suction device, the proportions for the pulmonary edema and vomit group were 100% and 66.7%, respectively. Conclusion: CMAC with inline suction was no different than CMAC with traditional suction and was associated with no statistically significant differences in median time to intubation or proportion of successful intubations. [West J Emerg Med

  18. Absence of suction feeding ichthyosaurs and its implications for triassic mesopelagic paleoecology.

    Science.gov (United States)

    Motani, Ryosuke; Ji, Cheng; Tomita, Taketeru; Kelley, Neil; Maxwell, Erin; Jiang, Da-yong; Sander, Paul Martin

    2013-01-01

    Mesozoic marine reptiles and modern marine mammals are often considered ecological analogs, but the extent of their similarity is largely unknown. Particularly important is the presence/absence of deep-diving suction feeders among Mesozoic marine reptiles because this would indicate the establishment of mesopelagic cephalopod and fish communities in the Mesozoic. A recent study suggested that diverse suction feeders, resembling the extant beaked whales, evolved among ichthyosaurs in the Triassic. However, this hypothesis has not been tested quantitatively. We examined four osteological features of jawed vertebrates that are closely linked to the mechanism of suction feeding, namely hyoid corpus ossification/calcification, hyobranchial apparatus robustness, mandibular bluntness, and mandibular pressure concentration index. Measurements were taken from 18 species of Triassic and Early Jurassic ichthyosaurs, including the presumed suction feeders. Statistical comparisons with extant sharks and marine mammals of known diets suggest that ichthyosaurian hyobranchial bones are significantly more slender than in suction-feeding sharks or cetaceans but similar to those of ram-feeding sharks. Most importantly, an ossified hyoid corpus to which hyoid retractor muscles attach is unknown in all but one ichthyosaur, whereas a strong integration of the ossified corpus and cornua of the hyobranchial apparatus has been identified in the literature as an important feature of suction feeders. Also, ichthyosaurian mandibles do not narrow rapidly to allow high suction pressure concentration within the oral cavity, unlike in beaked whales or sperm whales. In conclusion, it is most likely that Triassic and Early Jurassic ichthyosaurs were 'ram-feeders', without any beaked-whale-like suction feeder among them. When combined with the inferred inability for dim-light vision in relevant Triassic ichthyosaurs, the fossil record of ichthyosaurs does not suggest the establishment of modern

  19. Behaviour of a pre-stressed concrete pressure-vessel subjected to a high temperature gradient; Comportement d'un caisson en beton precontraint soumis a un gradient de temperature eleve

    Energy Technology Data Exchange (ETDEWEB)

    Dubois, F. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires; Bonvalet, Ch.; Dawance, G.; Marechal, J.C. [Centre Experimental de Recherches et d' Etudes du Batiment et des Travaux Publics (CEBTP), 76 - Harfleur (France)

    1965-07-01

    results obtained make it possible both to draw up a programme for future tests and to propose a calculation model for pre-stressed concrete pressure-vessels. (authors) [French] Apres avoir rappele les problemes poses par les caissons pour les reacteurs atomiques (formes des caissons, pressions, ouvertures, fondations, etc.), on expose l'interet presente par les caissons en beton precontraint, par rapport aux caissons en acier. Toutefois, l'utilisation des caissons en beton precontraint souleve de nombreuses difficultes liees aux proprietes des betons. Ainsi, faute de connaissances approfondies du materiau, il est necessaire de placer une peau d'etancheite en acier contre le beton, d'avoir un isolant thermique ou un circuit de refroidissement pour limiter les deformations et les contraintes, etc. Par suite, l'etude du comportement du beton precontraint et du caisson soumis a un gradient eleve de temperature peut apporter des informations utiles. Une maquette au l/10eme d'un caisson cylindrique en beton precontraint sans fond ni ouverture laterale, a ete realisee. Avant de decrire les essais effectues, quelques considerations theoriques sont developpees concernant les conditions de similitude 'modele reduit - ouvrage reel' et le calcul des sollicitations thermiques et mecaniques. La maquette de caisson en beton precontraint etait chauffee interieurement par un element de pyrotenax et refroidie exterieurement par un violent courant d'air. Le beton etait precontraint par des cables horizontaux et verticaux a 80 kg/cm{sup 2}; le gradient thermique atteignait 160 deg. C, Les deformations globales et locales, la variation de la teneur en eau, le module d'elasticite, la tension et le fluage des cables, la profondeur des fissures ont ete mesures au cours des differents essais. Les deformations globales observees sont compatibles avec les theories des deformations thermiques et le fluage des cables a atteint 20 a 30 pour cent

  20. Morphology, Kinematics, and Dynamics: The Mechanics of Suction Feeding in Fishes.

    Science.gov (United States)

    Day, Steven W; Higham, Timothy E; Holzman, Roi; Van Wassenbergh, Sam

    2015-07-01

    Suction feeding is pervasive among aquatic vertebrates, and our understanding of the functional morphology and biomechanics of suction feeding has recently been advanced by combining experimental and modeling approaches. Key advances include the visualization of the patterns of flow in front of the mouth of a feeding fish, the measurement of pressure inside their mouth cavity, and the employment of analytical and computational models. Here, we review the key components of the morphology and kinematics of the suction-feeding system of anatomically generalized, adult ray-finned fishes, followed by an overview of the hydrodynamics involved. In the suction-feeding apparatus, a strong mechanistic link among morphology, kinematics, and the capture of prey is manifested through the hydrodynamic interactions between the suction flows and solid surfaces (the mouth cavity and the prey). It is therefore a powerful experimental system in which the ecology and evolution of the capture of prey can be studied based on first principals. © The Author 2015. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved. For permissions please email: journals.permissions@oup.com.

  1. Investigation of seepage around the bucket skirt during installation in sand

    DEFF Research Database (Denmark)

    Koteras, Aleksandra Katarzyna; Ibsen, Lars Bo

    or along bucket skirt with known soil condition, bucket geometry and applied suction. The second aim of the study is to evaluate expressions for normalized seepage length, s/h, for different soil combinations and penetration depths. The seepage length is then 7 used to make a prediction of critical...... pressure that will create piping channels at exit, which is near to seabed and to the caisson wall, along bucket wall and at the tip. That is how the limits for suction installation can be assumed. Finally, the critical suction is used for predicting the reduction of penetration resistance and the method...... describing this approach is presented in the report with its assumptions. The method is called AAU CPT-based method and it is a great step in the development of practical design tool for bucket foundation installation process....

  2. Protection for work in the pressure tank of the pile G2; Protection des travaux dans le caisson de la pile G2

    Energy Technology Data Exchange (ETDEWEB)

    Chassany, J Ph; Rodier, J [Commissariat a l' Energie Atomique, Service de Protection contre les Radiations, Marcoule (France). Centre d' Etudes Nucleaires

    1961-07-01

    While the pile was shut down after a three-month run at full power, the secondary circuit was cleaned and some alterations were carried out. The pile contained 100 tons of uranium, half of which made up the periphery and was irradiated uranium. The possibility of carrying on work inside the pressure tank was not considered at the time of construction. Because of the heat and the irradiation it was only possible to remain in the pressure tank for a limited period of time, and several operators received doses of the order of 1.5 rem. Cotton clothing gave satisfactory protection against contamination and was more comfortable than the vinyl equipment. The work lasted for 17 days and involved 881 incursions into the pressure tank. (author) [French] Un nettoyage et des modifications ont ete realises dans le circuit secondaire pendant l'arret de la pile apres un fonctionnement de trois mois a pleine puissance. La pile contenait 100 tonnes d'uranium dont la moitie, composant la peripherie, etait de l'uranium irradie. La possibilite d'entreprendre un travail a l'interieur du caisson n'avait pas ete envisage lors de la construction. Le temps de sejour dans le caisson etait a la fois limite par l'irradiation et la chaleur, plusieurs operateurs, ont integre une dose de l'ordre de 1,5 rem. Les vetements de coton ont apporte une protection contre la contamination satisfaisante et un confort relatif par rapport aux equipements de vinyle. L'intervention a dure 17 jours, a comporte 881 entrees dans le caisson. (auteur)

  3. Turbulent flow with suction in smooth and rough pipes

    International Nuclear Information System (INIS)

    Verdier, Andre.

    1977-11-01

    It concerns an experimental study of turbulent flow inside a pipe with rough and porous wall and suction applied through it. The first part recall the basic knowledge concerning the turbulent flow with roughness. In second part statistical equations of fluid wall stress are written in the case of a permeable rough wall, in order to underline the respective role played by viscosity and pressure terms. In the third part the dynamic equilibrium of the flow is experimentally undertaken in the smooth and rough range with and without wall suction. Some empirical formulae are proposed for the mean velocity profiles in the inertial range and for friction velocity with suction. In the case of the sand roughness used, it does not seem that critical Reynolds number of transition from smooth to rough range is varied [fr

  4. A compliant underactuated hand with suction flow for underwater mobile manipulation

    KAUST Repository

    Stuart, Hannah S.

    2014-05-01

    © 2014 IEEE. Fingertip suction is investigated using a compliant, underactuated, tendon-driven hand designed for underwater mobile manipulation. Tendon routing and joint stiffnesses are designed to provide ease of closure while maintaining finger rigidity, allowing the hand to pinch small objects, as well as secure large objects, without diminishing strength. While the hand is designed to grasp a range of objects, the addition of light suction flow to the fingertips is especially effective for small, low-friction (slippery) objects. Numerical simulations confirm that changing suction parameters can increase the object acquisition region, providing guidelines for future versions of the hand.

  5. A compliant underactuated hand with suction flow for underwater mobile manipulation

    KAUST Repository

    Stuart, Hannah S.; Wang, Shiquan; Gardineer, Bayard; Christensen, David L.; Aukes, Daniel M.; Cutkosky, Mark

    2014-01-01

    © 2014 IEEE. Fingertip suction is investigated using a compliant, underactuated, tendon-driven hand designed for underwater mobile manipulation. Tendon routing and joint stiffnesses are designed to provide ease of closure while maintaining finger rigidity, allowing the hand to pinch small objects, as well as secure large objects, without diminishing strength. While the hand is designed to grasp a range of objects, the addition of light suction flow to the fingertips is especially effective for small, low-friction (slippery) objects. Numerical simulations confirm that changing suction parameters can increase the object acquisition region, providing guidelines for future versions of the hand.

  6. Absence of suction feeding ichthyosaurs and its implications for triassic mesopelagic paleoecology.

    Directory of Open Access Journals (Sweden)

    Ryosuke Motani

    Full Text Available Mesozoic marine reptiles and modern marine mammals are often considered ecological analogs, but the extent of their similarity is largely unknown. Particularly important is the presence/absence of deep-diving suction feeders among Mesozoic marine reptiles because this would indicate the establishment of mesopelagic cephalopod and fish communities in the Mesozoic. A recent study suggested that diverse suction feeders, resembling the extant beaked whales, evolved among ichthyosaurs in the Triassic. However, this hypothesis has not been tested quantitatively. We examined four osteological features of jawed vertebrates that are closely linked to the mechanism of suction feeding, namely hyoid corpus ossification/calcification, hyobranchial apparatus robustness, mandibular bluntness, and mandibular pressure concentration index. Measurements were taken from 18 species of Triassic and Early Jurassic ichthyosaurs, including the presumed suction feeders. Statistical comparisons with extant sharks and marine mammals of known diets suggest that ichthyosaurian hyobranchial bones are significantly more slender than in suction-feeding sharks or cetaceans but similar to those of ram-feeding sharks. Most importantly, an ossified hyoid corpus to which hyoid retractor muscles attach is unknown in all but one ichthyosaur, whereas a strong integration of the ossified corpus and cornua of the hyobranchial apparatus has been identified in the literature as an important feature of suction feeders. Also, ichthyosaurian mandibles do not narrow rapidly to allow high suction pressure concentration within the oral cavity, unlike in beaked whales or sperm whales. In conclusion, it is most likely that Triassic and Early Jurassic ichthyosaurs were 'ram-feeders', without any beaked-whale-like suction feeder among them. When combined with the inferred inability for dim-light vision in relevant Triassic ichthyosaurs, the fossil record of ichthyosaurs does not suggest the

  7. A Technique for Controlling Matric Suction on Filter Papers . GroWth ...

    African Journals Online (AJOL)

    'Abstract. Moist filter papers are widely usedfor seed gennination tests but their water confent and matric suction are not usually controlled. A technique for controlling filter paper matric suction is described and usedfor germination studies involving fresh and aged sorghum seed (Sorghummcolor (L) Moench). Filter papers ...

  8. A comparison of commercial light-emitting diode baited suction traps for surveillance of Culicoides in northern Europe.

    Science.gov (United States)

    Hope, Andrew; Gubbins, Simon; Sanders, Christopher; Denison, Eric; Barber, James; Stubbins, Francesca; Baylis, Matthew; Carpenter, Simon

    2015-04-22

    The response of Culicoides biting midges (Diptera: Ceratopogonidae) to artificial light sources has led to the use of light-suction traps in surveillance programmes. Recent integration of light emitting diodes (LED) in traps improves flexibility in trapping through reduced power requirements and also allows the wavelength of light used for trapping to be customized. This study investigates the responses of Culicoides to LED light-suction traps emitting different wavelengths of light to make recommendations for use in surveillance. The abundance and diversity of Culicoides collected using commercially available traps fitted with Light Emitting Diode (LED) platforms emitting ultraviolet (UV) (390 nm wavelength), blue (430 nm), green (570 nm), yellow (590 nm), red (660 nm) or white light (425 nm - 750 nm with peaks at 450 nm and 580 nm) were compared. A Centre for Disease Control (CDC) UV light-suction trap was also included within the experimental design which was fitted with a 4 watt UV tube (320-420 nm). Generalised linear models with negative binomial error structure and log-link function were used to compare trap abundance according to LED colour, meteorological conditions and seasonality. The experiment was conducted over 49 nights with 42,766 Culicoides caught in 329 collections. Culicoides obsoletus Meigen and Culicoides scoticus Downes and Kettle responded indiscriminately to all wavelengths of LED used with the exception of red which was significantly less attractive. In contrast, Culicoides dewulfi Goetghebuer and Culicoides pulicaris Linnaeus were found in significantly greater numbers in the green LED trap than in the UV LED trap. The LED traps collected significantly fewer Culicoides than the standard CDC UV light-suction trap. Catches of Culicoides were reduced in LED traps when compared to the standard CDC UV trap, however, their reduced power requirement and small size fulfils a requirement for trapping in logistically challenging areas or where many

  9. Investigation on compression behaviour of highly compacted GMZ01 bentonite with suction and temperature control

    International Nuclear Information System (INIS)

    Ye, W.M.; Zhang, Y.W.; Chen, B.; Zheng, Z.J.; Chen, Y.G.; Cui, Y.J.

    2012-01-01

    Highlights: ► Heating induced volumetric change of GMZ01 bentonite depends on suction. ► Suction has significant influence on compressibility. ► Temperature has slight influence on compressibility. - Abstract: In this paper, an oedometer with suction and temperature control was developed. Mechanical compaction tests have been performed on the highly compacted GMZ01 bentonite, which has been recognized as potential buffer/backfill material for construction of Chinese high-level radioactive waste (HLW) geological repository, under conditions of suction ranging from 0 to 110 MPa, temperature from 20 to 80 °C and vertical pressure from 0.1 to 80 MPa. Based on the test results, suction and temperature effects on compressibility parameters are investigated. Results reveal that: (1) at high suctions, heating induced an expansion, while contraction is induced by heating at low suctions. The thermal expansion coefficient of GMZ01 bentonite measured is 1 × 10 −4 °C −1 ; (2) with increasing suction, the elastic compressibility κ and the plastic compressibility λ(s) of the highly compacted GMZ01 bentonite decrease, while the pre-consolidation pressure increases markedly; (3) with increasing temperature, the elastic compressibility of compacted GMZ01 bentonite changes insignificantly, while the plastic compressibility λ(s) slightly decreases and the yield surface tends to shrink.

  10. A Technique for Controlling Matric Suction on Filter Papers Used in ...

    African Journals Online (AJOL)

    Moist filter papers are widely usedfor seed gennination tests but their water confent and matric suction are not usually controlled. A technique for controlling filter paper matric suction is described and usedfor germination studies involving fresh and aged sorghum seed (Sorghummcolor (L) Moench). Filter papers wetted to ...

  11. 21 CFR 870.4270 - Cardiopulmonary bypass cardiotomy suction line blood filter.

    Science.gov (United States)

    2010-04-01

    ... blood filter. 870.4270 Section 870.4270 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Devices § 870.4270 Cardiopulmonary bypass cardiotomy suction line blood filter. (a) Identification. A cardiopulmonary bypass cardiotomy suction line blood filter is a device used as part of a gas exchange (oxygenator...

  12. Reliability and criterion-related validity testing (construct) of the Endotracheal Suction Assessment Tool (ESAT©).

    Science.gov (United States)

    Davies, Kylie; Bulsara, Max K; Ramelet, Anne-Sylvie; Monterosso, Leanne

    2018-05-01

    To establish criterion-related construct validity and test-retest reliability for the Endotracheal Suction Assessment Tool© (ESAT©). Endotracheal tube suction performed in children can significantly affect clinical stability. Previously identified clinical indicators for endotracheal tube suction were used as criteria when designing the ESAT©. Content validity was reported previously. The final stages of psychometric testing are presented. Observational testing was used to measure construct validity and determine whether the ESAT© could guide "inexperienced" paediatric intensive care nurses' decision-making regarding endotracheal tube suction. Test-retest reliability of the ESAT© was performed at two time points. The researchers and paediatric intensive care nurse "experts" developed 10 hypothetical clinical scenarios with predetermined endotracheal tube suction outcomes. "Experienced" (n = 12) and "inexperienced" (n = 14) paediatric intensive care nurses were presented with the scenarios and the ESAT© guiding decision-making about whether to perform endotracheal tube suction for each scenario. Outcomes were compared with those predetermined by the "experts" (n = 9). Test-retest reliability of the ESAT© was measured at two consecutive time points (4 weeks apart) with "experienced" and "inexperienced" paediatric intensive care nurses using the same scenarios and tool to guide decision-making. No differences were observed between endotracheal tube suction decisions made by "experts" (n = 9), "inexperienced" (n = 14) and "experienced" (n = 12) nurses confirming the tool's construct validity. No differences were observed between groups for endotracheal tube suction decisions at T1 and T2. Criterion-related construct validity and test-retest reliability of the ESAT© were demonstrated. Further testing is recommended to confirm reliability in the clinical setting with the "inexperienced" nurse to guide decision-making related to endotracheal tube

  13. Analisis Perubahan Nilai Suction Akibat Hujan Terhadap Kestabilan Lereng

    OpenAIRE

    Martini, Martini

    2009-01-01

    Infiltration of rainfall into slope will have an effect on to condition of slope hydrology and more specifically to characteristic of slope soils, for example pore water pressure value, level of saturation, weight contents of soil, shear strength of soil. Pore water pressure value at dry soil condition or wet condition called as with pore water pressure value negatife or value suction. This suction value will tend to declines and in the end becomes equal to zero or bigger than 0 ( positive po...

  14. Comparative study of the characteristics of some suction devices for gas sampling applications

    International Nuclear Information System (INIS)

    Donguy, R.; Drouet, J.

    1959-06-01

    Gas sampling (used to determine the characteristics of dusts or aerosols contained in a gas) needs a suction device. In order to select the right device and the right conditions of use, the characteristics and performances of various suction devices (helicoidal and centrifugal aspirators, air pumps, volumetric pumps) have been experimentally measured: flow rate, head loss, sampling volume and duration, aerosol and dust concentration, gas density, nature of the gas, suction circuit configuration, etc

  15. Investigation on compression behaviour of highly compacted GMZ01 bentonite with suction and temperature control

    Energy Technology Data Exchange (ETDEWEB)

    Ye, W.M., E-mail: ye_tju@tongji.edu.cn [Key Laboratory of Geotechnical and Underground Engineering of Ministry of Education, Tongji University, Shanghai 200092 (China); United Research Center for Urban Environment and Sustainable Development, The Ministry of Education, Shanghai 200092 (China); Zhang, Y.W.; Chen, B.; Zheng, Z.J.; Chen, Y.G. [Key Laboratory of Geotechnical and Underground Engineering of Ministry of Education, Tongji University, Shanghai 200092 (China); Cui, Y.J. [Key Laboratory of Geotechnical and Underground Engineering of Ministry of Education, Tongji University, Shanghai 200092 (China); Ecole des Ponts ParisTech, UR Navier/CERMES 77455 (France)

    2012-11-15

    Highlights: Black-Right-Pointing-Pointer Heating induced volumetric change of GMZ01 bentonite depends on suction. Black-Right-Pointing-Pointer Suction has significant influence on compressibility. Black-Right-Pointing-Pointer Temperature has slight influence on compressibility. - Abstract: In this paper, an oedometer with suction and temperature control was developed. Mechanical compaction tests have been performed on the highly compacted GMZ01 bentonite, which has been recognized as potential buffer/backfill material for construction of Chinese high-level radioactive waste (HLW) geological repository, under conditions of suction ranging from 0 to 110 MPa, temperature from 20 to 80 Degree-Sign C and vertical pressure from 0.1 to 80 MPa. Based on the test results, suction and temperature effects on compressibility parameters are investigated. Results reveal that: (1) at high suctions, heating induced an expansion, while contraction is induced by heating at low suctions. The thermal expansion coefficient of GMZ01 bentonite measured is 1 Multiplication-Sign 10{sup -4} Degree-Sign C{sup -1}; (2) with increasing suction, the elastic compressibility {kappa} and the plastic compressibility {lambda}(s) of the highly compacted GMZ01 bentonite decrease, while the pre-consolidation pressure increases markedly; (3) with increasing temperature, the elastic compressibility of compacted GMZ01 bentonite changes insignificantly, while the plastic compressibility {lambda}(s) slightly decreases and the yield surface tends to shrink.

  16. Suction of MHD boundary layer flows

    International Nuclear Information System (INIS)

    Rao, B.N.

    1985-01-01

    The boundary layer growth with tensor electrical conductivity and the transpiration number has been examined using local nonsimilarity solutions method. It is found that suction will cause the increase in wall shearing stress and decrease in thicknesses of the boundary layer. (Auth.)

  17. Volume of blood suctioned during vacuum-assisted breast biopsy predicts later hematoma formation

    Directory of Open Access Journals (Sweden)

    Panopoulou Effrosyni

    2010-03-01

    Full Text Available Abstract Background To evaluate whether the volume of blood suctioned during vacuum-assisted breast biopsy (VABB is associated with hematoma formation and progression, patient's age and histology of the lesion. Findings 177 women underwent VABB according to standardized protocol. The volume of blood suctioned and hematoma formation were noted at the end of the procedure, as did the subsequent development and progression of hematoma. First- and second-order logistic regression was performed, where appropriate. Cases with hematoma presented with greater volume of blood suctioned (63.8 ± 44.7 cc vs. 17.2 ± 32.9 cc; p Conclusion The likelihood of hematoma is increasing along with increasing amount of blood suctioned, reaching a plateau approximately at 80 cc of blood lost.

  18. Pilot Study Comparing Closed Versus Open Tracheal Suctioning in Postoperative Neonates and Infants With Complex Congenital Heart Disease.

    Science.gov (United States)

    Tume, Lyvonne N; Baines, Paul B; Guerrero, Rafael; Hurley, Margaret A; Johnson, Robert; Kalantre, Atul; Ramaraj, Ram; Ritson, Paul C; Walsh, Laura; Arnold, Philip D

    2017-07-01

    To determine the hemodynamic effect of tracheal suction method in the first 36 hours after high-risk infant heart surgery on the PICU and to compare open and closed suctioning techniques. Pilot randomized crossover study. Single PICU in United Kingdom. Infants undergoing surgical palliation with Norwood Sano, modified Blalock-Taussig shunt, or pulmonary artery banding in the first 36 hours postoperatively. Infants were randomized to receive open or closed (in-line) tracheal suctioning either for their first or second study tracheal suction in the first 36 hours postoperatively. Twenty-four infants were enrolled over 18 months, 11 after modified Blalock-Taussig shunt, seven after Norwood Sano, and six after pulmonary artery banding. Thirteen patients received the open suction method first followed by the closed suction method second, and 11 patients received the closed suction method first followed by the open suction method second in the first 36 hours after their surgery. There were statistically significant larger changes in heart rate (p = 0.002), systolic blood pressure (p = 0.022), diastolic blood pressure (p = 0.009), mean blood pressure (p = 0.007), and arterial saturation (p = 0.040) using the open suction method, compared with closed suctioning, although none were clinically significant (defined as requiring any intervention). There were no clinically significant differences between closed and open tracheal suction methods; however, there were statistically significant greater changes in some hemodynamic variables with open tracheal suctioning, suggesting that closed technique may be safer in children with more precarious physiology.

  19. Rekonstruksi pada Perforasi Palatum Akibat Pneggunaan Gigi Tiruan Lengkap Rahang Atas dengan Suction Cup

    Directory of Open Access Journals (Sweden)

    Cristiani Nadya Pramasari

    2012-12-01

    Full Text Available Latar belakang. Pemasangan suction cup pada gigi tiruan lengkap rahang atas merupakan salah satu cara untuk meningkatkan referensi. Kondisi vakum oleh karena suction cup ini dalam waktu jangka panjang dan tidak terkontrol mengakibatkan nekrosis jaringan yaitu adanya perforasi palatum. Tujuan. Melaporkan rekonstruksi penutupan perforasi palatum sebagai komplikasi penggunaan gigi tiruan lengkap rahang atas dengan suction cup. Laporan Kasus. Pada tanggal 11 September 2012 seorang pria berusia 64 tahun datang ke Poliklinik Bedah Mulut RSUP dr. Sardjito Yogyakarta dengan keluhan terdapat lubang pada langit-langit. Pasien menggunakan gigi palsu buatan tukang gigi dengan perekat berbahan karet pada langit-langit selama 5 tahun. Selama penggunaan gigi palsu pasien sering mengalami sakit dan pembengkakan di langit-langit sampai keluar nanah dan akhirnya terbentuk lubang sehingga jika minum air keluar dari hidung. Pemeriksaan rontgen oklusal rahang atas tampak adanya resorbsi regio palatum durum. Rekonstruksi menggunakan teknik push back modifikasi dilakukan untuk penutupan perforasi palatum di bawah anestesi umum. Kesimpulan. Suction cup pada gigi tiruan lengkap rahang atas mengakibatkan kerusakan jaringan lunak dan jaringan keras rongga mulut. Perforasi palatum yang diakibatkan oleh suction cup ini dapat dilakukan rekonstruksi dengan teknik push back dengan hasil yang cukup optimal.   Background. Suction cups are used to get retention of the complete dentures. The uncontrolled constant vacuum created by the suction cup induces necrosis of tissues and perforation ofpalate. Objective. To report reconstruction for palatal perforation closure as a complication due to prolonged use of maxillary denture with suction cup. Case Report. A 64 years old male patient came to the Department of Oral Surgery, Sardjito General Hospital Yogyakarta on September 11, 2012 with the complaint of hole in his palate. He was wearing dentures for the past 5 years. He also

  20. MAXIMUM AIR SUCTION INTO HORIZONTAL OPEN ENDED CYLINDRICAL LOUVERED PIPE

    Directory of Open Access Journals (Sweden)

    SAMEER RANJAN SAHU

    2017-02-01

    Full Text Available The main approach behind the present numerical investigation is to estimate the mass flow rate of air sucked into a horizontal open-ended louvered pipe from the surrounding atmosphere. The present numerical investigation has been performed by solving the conservation equations for mass, momentum and energy along with two equation based k-ɛ model for a louvered horizontal cylindrical pipe by finite volume method. It has been found from the numerical investigation that mass suction rate of air into the pipe increases with increase in louvered opening area and the number of nozzles used. Keeping other parameters fixed, for a given mass flow rate there exists an optimum protrusion of nozzle for highest mass suction into the pipe. It was also found from the numerical investigation that increasing the pipe diameter the suction mass flow rate of air was increased.

  1. Bernoulli Suction Effect on Soap Bubble Blowing?

    Science.gov (United States)

    Davidson, John; Ryu, Sangjin

    2015-11-01

    As a model system for thin-film bubble with two gas-liquid interfaces, we experimentally investigated the pinch-off of soap bubble blowing. Using the lab-built bubble blower and high-speed videography, we have found that the scaling law exponent of soap bubble pinch-off is 2/3, which is similar to that of soap film bridge. Because air flowed through the decreasing neck of soap film tube, we studied possible Bernoulli suction effect on soap bubble pinch-off by evaluating the Reynolds number of airflow. Image processing was utilized to calculate approximate volume of growing soap film tube and the volume flow rate of the airflow, and the Reynolds number was estimated to be 800-3200. This result suggests that soap bubbling may involve the Bernoulli suction effect.

  2. CAISSON TYPE HOLLOW FLOOR SLABS OF MONOLITHIC MULTI-STOREYED BUILDINGS

    Directory of Open Access Journals (Sweden)

    Malakhova Anna Nikolaevna

    2016-06-01

    Full Text Available One of the disadvantages of building structures made of reinforced concrete is their considerable weight. One of the trends to decrease the weight of concrete structures, including floor slabs, is the arrangement of voids in the cross-sectional building structures. In Russian and foreign practice paper, cardboard and plastic tubes has been used for creation of voids in the construction of monolithic floor slabs. Lightweight concretes were also used for production of precast hollow core floor slabs. The article provides constructive solutions of precast hollow core floor slabs and solid monolithic slabs that were used in the construction of buildings before wide use of large precast hollow core floor slabs. The article considers the application of caisson hollow core floor slabs for modern monolithic multi-storeyed buildings. The design solutions of such floor slabs, experimental investigations and computer modeling of their operation under load were described in this article. The comparative analysis of the calculation results of computer models of a hollow slabs formed of rod or plastic elements showed the similarity of calculation results.

  3. Hydrodynamics of suction feeding in fish

    NARCIS (Netherlands)

    Muller, M.

    1983-01-01

    1. Suction feeding is the dominant way to obtain food in teleosts. Its high demands on structures due to the required velocities and forces leads to the expectation that a biophysical analysis will aid to reveal the adaptive significance of head and body structures related to this

  4. Suction forces generated by passive bile bag drainage on a model of post-subdural hematoma evacuation.

    Science.gov (United States)

    Tenny, Steven O; Thorell, William E

    2018-05-05

    Passive drainage systems are commonly used after subdural hematoma evacuation but there is a dearth of published data regarding the suction forces created. We set out to quantify the suction forces generated by a passive drainage system. We created a model of passive drainage after subdural hematoma evacuation. We measured the maximum suction force generated with a bile bag drain for both empty drain tubing and fluid-filled drain tube causing a siphoning effect. We took measurements at varying heights of the bile bag to analyze if bile bag height changed suction forces generated. An empty bile bag with no fluid in the drainage tube connected to a rigid, fluid-filled model creates minimal suction force of 0.9 mmHg (95% CI 0.64-1.16 mmHg). When fluid fills the drain tubing, a siphoning effect is created and can generate suction forces ranging from 18.7 to 30.6 mmHg depending on the relative position of the bile bag and filled amount of the bile bag. The suction forces generated are statistically different if the bile bag is 50 cm below, level with or 50 cm above the experimental model. Passive bile bag drainage does not generate significant suction on a fluid-filled rigid model if the drain tubing is empty. If fluid fills the drain tubing then siphoning occurs and can increase the suction force of a passive bile bag drainage system to levels comparable to partially filled Jackson-Pratt bulb drainage.

  5. Study on the performance improvement of multiblade fans. Effects of suction cones; Tayoku fan no seino kaizen ni kansuru kenkyu. Suction cone no eikyo

    Energy Technology Data Exchange (ETDEWEB)

    Kuratani, F.; Ogawa, T. [Hyogo University of Teacher Education, Hyogo (Japan); Yamamoto, S.

    1999-07-25

    In order to improve the performance of a multiblade fan, the effects of three types of suction cones of the fan casing on the fan efficiency and noise are investigated experimentally. The first type of the suction cone is the insertion type, which is inserted into the inside of the fan impeller. The second type is the extrusion type, which extrudes outside from the casing surface. The third type is the combination type of two types. The results of those three types are compared with those of the commonly used suction cone. The followings are made clear: (1) The insertion type and the extrusion type are effective in improving the efficiency and reducing noise. (2) The optimal lengths of the insertion and the extrusion exist. (3) The combination type is more effective in improving the efficiency. (4) The combination type with the skewed cutoff of the fan casing shows the best effect. (author)

  6. Characterization of zebrafish larvae suction feeding flow using μPIV and optical coherence tomography

    OpenAIRE

    Pekkan, Kerem; Uslu, Fazıl E.; Chang, Brain; Mani, Karthick; Chen, Chia-Yuan; Holzman, Roi

    2016-01-01

    The hydrodynamics of suction feeding is critical for the survival of fish larvae; failure to capture food during the onset of autonomous feeding can rapidly lead to starvation and mortality. Fluid mechanics experiments that investigate the suction feeding of suspended particles are limited to adult fishes, which operate at large Reynolds numbers. This manuscript presents the first literature results in which the external velocity fields generated during suction feeding of early zebrafish larv...

  7. Effects of Lavender Inhalant on the Pain during Endotracheal Suctioning in Intensive Care Unit Patients

    Directory of Open Access Journals (Sweden)

    M. Taheri Rezgh Abadi

    2017-09-01

    Full Text Available Aims: Patients undergoing artificial ventilation require tracheal tube suction because of inability to clear their effective airways, which is usually a painful process for the patients. The aim of this study was to investigate the effect of spike lavender’s inhalant on pain during tracheal tube suctioning in ICU intubated patients. Materials & Methods: In this double-blinded randomized clinical trial, 60 intubated patients hospitalized in ICU of Shahid Modarres Hospital of Kashmar City, Iran, in 2017 were selected by available and simple sampling method, and were randomly divided into 2 control and case groups (each 30 individuals. Before the standard suctioning process, the test group patients received inhalant of 2% spike lavender for 5 minutes and the control group received inhalant of distilled water. The level of pain was recorded before and during tracheal tube suctioning. Data were analyzed by SPSS 16 software using independent T, paired T, Fisher and Mann-Whitney U tests. Findings: There was no significant difference in pain score before tracheal tube suction between 2 groups (p>0.05. However, there were significant differences between the level of pain during tracheal tube suctioning and the pain was increased in both groups, but this increase was significantly higher in the control group (p<0.001. Conclusion: Spike lavender’s inhalant is effective on pain reduction during suctioning process of ICU intubated patients.

  8. Device for the prehension by means of suction cups

    International Nuclear Information System (INIS)

    Gabillet, Maurice

    1980-01-01

    The difficulties encountered while utilising suction-cups, are mainly caused by the skirts. The skirts are more or less adaptable to the surface of the objects to be handled. The skirt of the device presented, is made out of a round supple elastic bag containing solid particles. By creating a vacuum in the bag, the particles become a solid entity. The bag filled with the particles becomes rigid and can take exactly the shape of the object to be lifted. By creating a second vacuum in the axis of the bag, the object can be lifted. Several suction-cups can be used simultaneously

  9. Corner Separation Control by Boundary Layer Suction Applied to a Highly Loaded Axial Compressor Cascade

    Directory of Open Access Journals (Sweden)

    Yangwei Liu

    2014-11-01

    Full Text Available Control of corner separation has attracted much interest due to its improvement of performance and energy utilization in turbomachinery. Numerical studies have been performed under both design and off-design flow conditions to investigate the effects of boundary layer suction (BLS on corner separation in a highly loaded compressor cascade. Two new BLS slot configurations are proposed and a total of five suction slot configurations were studied and compared. Averaged static pressure rise, exit loss coefficient, passage blockage and flow turning angle have been given and compared systematically over a range of operation incidence angles. Distributions of significant loss removal, blade loading, exit deviation and total pressure loss at 3 degree and 7 degree incidence have also been studied. Under the same suction mass flows of 0.7% of the inlet mass flows, the pitchwise suction slot on the endwall shows a better optimal performance over the whole operation incidence among single suction slots. By using of the new proposed compound slot configuration with one spanwise slot on the blade suction side and one pitchwise slot on the endwall, the maximum reduction of total pressure loss at 7 degree incidence can be 39.4%.

  10. Functional morphology of the feeding apparatus, feeding constraints, and suction performance in the nurse shark Ginglymostoma cirratum.

    Science.gov (United States)

    Motta, Philip J; Hueter, Robert E; Tricas, Timothy C; Summers, Adam P; Huber, Daniel R; Lowry, Dayv; Mara, Kyle R; Matott, Michael P; Whitenack, Lisa B; Wintzer, Alpa P

    2008-09-01

    The nurse shark, Ginglymostoma cirratum, is an obligate suction feeder that preys on benthic invertebrates and fish. Its cranial morphology exhibits a suite of structural and functional modifications that facilitate this mode of prey capture. During suction-feeding, subambient pressure is generated by the ventral expansion of the hyoid apparatus and the floor of its buccopharyngeal cavity. As in suction-feeding bony fishes, the nurse shark exhibits expansive, compressive, and recovery kinematic phases that produce posterior-directed water flow through the buccopharyngeal cavity. However, there is generally neither a preparatory phase nor cranial elevation. Suction is generated by the rapid depression of the buccopharyngeal floor by the coracoarcualis, coracohyoideus, and coracobranchiales muscles. Because the hyoid arch of G. cirratum is loosely connected to the mandible, contraction of the rectus cervicis muscle group can greatly depress the floor of the buccopharyngeal cavity below the depressed mandible, resulting in large volumetric expansion. Suction pressures in the nurse shark vary greatly, but include the greatest subambient pressures reported for an aquatic-feeding vertebrate. Maximum suction pressure does not appear to be related to shark size, but is correlated with the rate of buccopharyngeal expansion. As in suction-feeding bony fishes, suction in the nurse shark is only effective within approximately 3 cm in front of the mouth. The foraging behavior of this shark is most likely constrained to ambushing or stalking due to the exponential decay of effective suction in front of the mouth. Prey capture may be facilitated by foraging within reef confines and close to the substrate, which can enhance the effective suction distance, or by foraging at night when it can more closely approach prey.

  11. Performance of high-area-ratio annular dump diffuser using suction-stabilized-vortex flow control

    Science.gov (United States)

    Juhasz, A. J.; Smith, J. M.

    1977-01-01

    A short annular dump diffuser having a geometry conductive to formation of suction stabilized toroidal vortices in the region of abrupt area change was tested. The overall diffuser area ratio was 4.0 and the length to inlet height ratio was 2.0. Performance data were obtained at near ambient temperature and pressure for inlet Mach numbers of 0.18 and 0.30 with suction rates ranging from 0 to 18 percent of total inlet mass flowrate. Results show that the exit velocity profile could be readily biased toward either wall by adjustment of inner and outer wall suction rates. Symmetric exit velocity profiles were inherently unstable with a tendency to revert to a hub or tip bias. Diffuser effectiveness was increased from about 38 percent without suction to over 85 percent at a total suction rate of 10 to 12 percent. At the same time diffuser total pressure loss was reduced from 3.1 percent to 1.1 percent at an inlet Mach number of 0.3.

  12. Modulation method of scroll compressor based on suction gas bypass

    International Nuclear Information System (INIS)

    Wang Baolong; Han Linjun; Shi Wenxing; Li Xianting

    2012-01-01

    The air conditioners and heat pumps tend to work in much mild environments and part load situations rather than provide the rated full capacity under severe rated testing conditions. Both the capacity and inner compression ratio of the compressor should be regulated according to the working condition for higher energy efficiency and occupants’ comfort. A potential modulating technology of the scroll compressor, suction gas bypass, is investigated in this paper. The principle and operation method are illuminated and the adaptability is validated by experiments and simulations. As a conclusion, an appropriate suction gas bypass can reduce the inner compression loss of the scroll compressor under over compression conditions, enhance the system COP and also largely decrease the heating/cooling capacity of the refrigeration/heat pump system. - Highlights: ► Suction gas bypass (SGB) is an effective regulating method of scroll compressor. ► SGB reduces the inner compression loss under over compression conditions. ► SGB largely decreases the heating/cooling capacity of the refrigeration system.

  13. Characterization of zebrafish larvae suction feeding flow using μPIV and optical coherence tomography

    Science.gov (United States)

    Pekkan, Kerem; Chang, Brian; Uslu, Fazil; Mani, Karthick; Chen, Chia-Yuan; Holzman, Roi

    2016-07-01

    The hydrodynamics of suction feeding is critical for the survival of fish larvae; failure to capture food during the onset of autonomous feeding can rapidly lead to starvation and mortality. Fluid mechanics experiments that investigate the suction feeding of suspended particles are limited to adult fishes, which operate at large Reynolds numbers. This manuscript presents the first literature results in which the external velocity fields generated during suction feeding of early zebrafish larvae (2500-20,000 μm total length) are reported using time-resolved microscopic particle image velocimetry. For the larval stages studied, the maximum peak suction velocity of the inflow bolus is measured at a finite distance from the mouth tip and ranges from 1 to 8 mm/s. The average pressure gradient and the velocity profile proximal to the buccal (mouth) cavity are calculated, and two distinct trends are identified. External recirculation regions and reverse flow feeding cycles are also observed and quantified. One of the unresolved questions in fish suction feeding is the shape and dynamics of the buccal cavity during suction feeding; optical coherence tomography imaging is found to be useful for reconstructing the mouth kinematics. The projected area of the mouth cavity during the feeding cycle varies up to 160 and 22 % for the transverse and mid-sagittal planes, respectively. These findings can inspire novel hydrodynamically efficient biomedical and microfluidic devices.

  14. New approach to the suction force at the leading edge of a profile with zero thickness

    NARCIS (Netherlands)

    Sparenberg, JA; de Jager, EM

    2004-01-01

    This paper considers the suction force at the leading edge of a profile with zero thickness in an incompressible and inviscid fluid flow. The theory is linear, and the approach to the suction force is from the innerside of the profile. It is shown that the suction force can be considered as an

  15. Pad for holding a load against a surface by suction

    International Nuclear Information System (INIS)

    Farmer, R.C.; Goldsmith, H.A.; Proudlove, M.J.

    1981-01-01

    This invention concerns suction pads for supporting loads. Specifically, the suction pad is part of a pair of pads located at the ends of a bridge forming a vehicle for transporting instruments for the non-destructive testing of a large vessel intended to contain a fuel assembly for a nuclear reactor immersed in a liquid metal coolant. For example, the vehicle is of the type described in the French patent application filed this day under the heading 'Vehicle for transporting instruments for testing against a wall' [fr

  16. INCOMPRESSIBLE LAMINAR BOUNDARY LAYER CONTROL BY BLOWING AND SUCTION

    Directory of Open Access Journals (Sweden)

    AZZEDINE NAHOUI

    2013-12-01

    Full Text Available A two-dimensional incompressible laminar boundary layer and its control using blowing and suction over a flat plate and around the NACA 0012 and 661012 profiles, is studied numerically. The study is based on the Prandtl boundary layer model using the finite differences method and the Crank-Nicolson scheme. The velocity distribution, the boundary layer thickness and the friction coefficient, are determined and presented with and without control. The application of the control technique, has demonstrated its positive effect on the transition point and the friction coefficient. Both control procedures are compared for different lengths, speeds and angles of blowing and suction.

  17. Reliable site for suction blister induction and harvesting

    Directory of Open Access Journals (Sweden)

    Laxmisha Chandrashekar

    2005-01-01

    Full Text Available Background: Suction blister grafting is a useful modality of treatment of patients with resistant and stable vitiligo. However, there have been no detailed studies to find out the best donor site for blister formation. Methods: The study was conducted between the period of October 2004 and February 2005 in the dermatology department at a tertiary care center. Nine patients with vitiligo (focal vitiligo, 3; mucosal vitiligo, 2; acrofacial vitiligo, 2; vitiligo vulgaris, 1; and segmental vitiligo, 1 were selected for blister harvesting and grafting. The blisters were raised using the method described by Gupta et al. Results: Suction blisters were attempted to be raised at 52 sites, but only 38 blisters could be raised, 24 complete and 14 incomplete. Blisters were raised in all the three cases on the flexor aspect of the arm (100%, 15 of 17 cases (88.2% on the flexor aspect of the forearm, 4 of 5 cases (80% on the abdomen, 11 of 16 cases (68.7% on the anterolateral thigh, and less frequently over leg or foot. Complete blisters were formed in 13/15 cases (86.6% on the flexor aspect of the forearm, 6/11 cases (54.5% on the anterolateral thigh, and in all cases over leg. Conclusion: The flexor aspect of the forearm is a good site for suction blister harvesting.

  18. Suppression of the secondary flow in a suction channel of a large centrifugal pump

    International Nuclear Information System (INIS)

    Torii, D; Nagahara, T; Okihara, T

    2013-01-01

    The suction channel configuration of a large centrifugal pump with a 90-degree bend was studied in detail to suppress the secondary flow at the impeller inlet for improving suction performance. Design of experiments (DOE) and computational fluid dynamics (CFD) were used to evaluate the sensitivity of several primary design parameters of the suction channel. A DOE is a powerful tool to clarify the sensitivity of objective functions to design parameters with a minimum of trials. An L9 orthogonal array was adopted in this study and nine suction channels were designed, through which the flow was predicted by steady state calculation. The results indicate that a smaller bend radius with a longer straight nozzle, distributed between the bend and the impeller, suppresses the secondary flow at the impeller inlet. An optimum ratio of the cross sectional areas at the bend inlet and outlet was also confirmed in relationship to the contraction rate of the downstream straight nozzle. These findings were obtained by CFD and verified by experiments. The results will aid the design of large centrifugal pumps with better suction performance and higher reliability

  19. Prospective randomized trial compares suction versus water seal for air leaks.

    Science.gov (United States)

    Cerfolio, R J; Bass, C; Katholi, C R

    2001-05-01

    Surgeons treat air leaks differently. Our goal was to evaluate whether it is better to place chest tubes on suction or water seal for stopping air leaks after pulmonary surgery. A second goal was to evaluate a new classification system for air leaks that we developed. Patients were prospectively randomized before surgery to receive suction or water seal to their chest tubes on postoperative day (POD) #2. Air leaks were described and quantified daily by a classification system and a leak meter. The air-leak meter scored leaks from 1 (least) to 7 (greatest). The group randomized to water seal stayed on water seal unless a pneumothorax developed. On POD #2, 33 of 140 patients had an air leak. Eighteen patients had been preoperatively randomized to water seal and 15 to suction. Air leaks resolved in 12 (67%) of the water seal patients by the morning of POD #3. All 6 patients whose air leak did not stop had a leak that was 4/7 or greater (p leak meter. Of the 15 patients randomized to suction, only 1 patient's air leak (7%) resolved by the morning of POD #3. The randomization aspect of the trial was ended and statistical analysis showed water seal was superior (p = 0.001). The remaining 14 patients were then placed to water seal and by the morning of POD #4, 13 patients' leaks had stopped. Of the 32 total patients placed to seal, 7 (22%) developed a pneumothorax and 6 of these 7 patients had leaks that were 4/7 or greater (p = 0.001). Placing chest tubes on water seal seems superior to wall suction for stopping air leaks after pulmonary resection. However, water seal does not stop expiratory leaks that are 4/7 or greater. Pneumothorax may occur when chest tubes are placed on seal with leaks this large.

  20. Necessity of suction drains in gynecomastia surgery.

    Science.gov (United States)

    Keskin, Mustafa; Sutcu, Mustafa; Cigsar, Bulent; Karacaoglan, Naci

    2014-05-01

    The aim of gynecomastia surgery is to restore a normal chest contour with minimal signs of breast surgery. The authors examine the rate of complications in gynecomastia surgery when no closed-suction drains are placed. One hundred thirty-eight consecutive male patients who underwent gynecomastia surgery without drains were retrospectively analyzed to determine whether the absence of drains adversely affected patient outcomes. Patients were managed by ultrasonic-assisted liposuction both with and without the pull-through technique. The mean age of the patients was 29 years, and the mean volume of breast tissue aspirated was 350 mL per beast. Pull-through was needed in 23 cases. There was only 1 postoperative hematoma. These results are comparable with previously published data for gynecomastia surgery in which drains were placed, suggesting that the absence of drains does not adversely affect postoperative recovery. Routine closed-suction drainage after gynecomastia surgery is unnecessary, and it may be appropriate to omit drains after gynecomastia surgery.

  1. CFD Analysis of a Centrifugal Fan for Performance Enhancement using Converging Boundary Layer Suction Slots

    OpenAIRE

    K. Vasudeva Karanth; N. Yagnesh Sharma

    2009-01-01

    Generally flow behavior in centrifugal fan is observed to be in a state of instability with flow separation zones on suction surface as well as near the front shroud. Overall performance of the diffusion process in a centrifugal fan could be enhanced by judiciously introducing the boundary layer suction slots. With easy accessibility of CFD as an analytical tool, an extensive numerical whole field analysis of the effect of boundary layer suction slots in discrete regions ...

  2. Modelling suction instabilities in soils at varying degrees of saturation

    Directory of Open Access Journals (Sweden)

    Buscarnera Giuseppe

    2016-01-01

    Full Text Available Wetting paths imparted by the natural environment and/or human activities affect the state of soils in the near-surface, promoting transitions across different regimes of saturation. This paper discusses a set of techniques aimed at quantifying the role of hydrologic processes on the hydro-mechanical stability of soil specimens subjected to saturation events. Emphasis is given to the mechanical conditions leading to coupled flow/deformation instabilities. For this purpose, energy balance arguments for three-phase systems are used to derive second-order work expressions applicable to various regimes of saturation. Controllability analyses are then performed to relate such work input with constitutive singularities that reflect the loss of strength under coupled and/or uncoupled hydro-mechanical forcing. A suction-dependent plastic model is finally used to track the evolution of stability conditions in samples subjected to wetting, thus quantifying the growth of the potential for coupled failure modes upon increasing degree of saturation. These findings are eventually linked with the properties of the field equations that govern pore pressure transients, thus disclosing a conceptual link between the onset of coupled hydro-mechanical failures and the evolution of suction with time. Such results point out that mathematical instabilities caused by a non-linear suction dependent behaviour play an important role in the advanced constitutive and/or numerical tools that are commonly used for the analysis of geomechanical problems in the unsaturated zone, and further stress that the relation between suction transients and soil deformations is a key factor for the interpretation of runaway failures caused by intense saturation events.

  3. 21 CFR 878.5040 - Suction lipoplasty system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Suction lipoplasty system. 878.5040 Section 878.5040 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED...) Classification. Class II (special controls). Consensus standards and labeling restrictions. [63 FR 7705, Feb. 17...

  4. Numerical simulation and analysis of cavitation flows in a double suction centrifugal pump

    International Nuclear Information System (INIS)

    Meng, G; Tan, L; Cao, S L; Jian, W; Liu, W W; Jiang, D J

    2015-01-01

    Cavitation is an unsteady phenomenon, which is nearly inevitable in pumps. It would degrade the pump performance, generate vibrations and noises, and even erode pump flow passage components. The double suction centrifugal pump at design flow rate and large flow rate is numerically simulated using the k-ω turbulence model and the mass transport cavitation model. As a result, the calculated variation of pump head with pump inlet pressure agreed well with the experimental data. The results demonstrate that the numerical model and method can accurately predict the cavitation flows in a double suction centrifugal pump. The cavitation characteristics are analysed in great details. In addition, based on the calculation results, the reason that the plunge of pump head curve is revealed. It is found that the steep fall of pump head happens when the cavity reaches the blade to blade throat and the micro-vortex group appears at the back of the blade suction side. At the same time, this practice can provide guidance for the optimal design of double suction pumps

  5. External suction versus water seal after selective pulmonary resection for lung neoplasm: a systematic review.

    Directory of Open Access Journals (Sweden)

    Tong Qiu

    Full Text Available OBJECTIVE: To evaluate whether external suction is more advantageous than water seal in patients undergoing selective pulmonary resection (SPR for lung neoplasm. SUMMARY OF BACKGROUND DATA: Whether external suction should be routinely applied in postoperative chest drainage is still unclear, particularly for lung neoplasm patients. To most surgeons, the decision is based on their clinical experience. METHODS: Randomized control trials were selected. The participants were patients undergoing SPR with lung neoplasm. Lung volume reduction surgery and pneumothorax were excluded. Suction versus non-suction for the intervention. The primary outcome was the incidence of persistent air leak (PAL. The definition of PAL was air leak for more than 3-7 days. The secondary outcomes included air leak duration, time of drainage, postoperative hospital stay and the incidence of postoperative pneumothorax. Studies were identified from literature collections through screening. Bias was analyzed and meta-analysis was used. RESULTS: From the 1824 potentially relevant trials, 6 randomized control trials involving 676 patients were included. There was no difference between external suction and water seal in decreasing the incidence of PAL [95% confidence interval (CI 0.81-2.16; z = 1.10; P = 0.27]. Regarding secondary outcomes, there were no differences in time of drainage (95% CI-0.36-1.56, P = 0.22, postoperative hospital stay (95% CI -.31-.54, P = 0.87 or incidence of postoperative pneumothorax (95% CI 0.18-.02, P = 0.05 between external suction and water seal. CONCLUSIONS: For participants, no differences are identified in terms of PAL incidence, drainage time, length of postoperative hospital stay or incidence of postoperative pneumothorax between external suction and water seal. The bias analysis should be emphasized. To the limitations of the bias and methodological differences among the included studies, we have no recommendation on

  6. Storage depot for radioactive material

    International Nuclear Information System (INIS)

    Szulinski, M.J.

    1983-01-01

    Vertical drilling of cylindrical holes in the soil, and the lining of such holes, provides storage vaults called caissons. A guarded depot is provided with a plurality of such caissons covered by shielded closures preventing radiation from penetrating through any linear gap to the atmosphere. The heat generated by the radioactive material is dissipated through the vertical liner of the well into the adjacent soil and thus to the ground surface so that most of the heat from the radioactive material is dissipated into the atmosphere in a manner involving no significant amount of biologically harmful radiation. The passive cooling of the radioactive material without reliance upon pumps, personnel, or other factor which might fail, constitutes one of the most advantageous features of this system. Moreover this system is resistant to damage from tornadoes or earthquakes. Hermetically sealed containers of radioactive material may be positioned in the caissons. Loading vehicles can travel throughout the depot to permit great flexibility of loading and unloading radioactive materials. Radioactive material can be shifted to a more closely spaced caisson after ageing sufficiently to generate much less heat. The quantity of material stored in a caisson is restricted by the average capacity for heat dissipation of the soil adjacent such caisson

  7. Assessment of Feasibility of Suction Pile/Anchor Installation and Pullout Testing through Field Tests

    Directory of Open Access Journals (Sweden)

    R. Vijaya

    2014-09-01

    Full Text Available Suction pile anchors are large cylindrical (inverted bucket type structure open at the bottom and closed at the top and largely used for mooring of offshore platforms, exploratory vessels etc. Prediction of the mooring capacity of suction piles is a critical issue faced by the design engineers and rational methods are required to produce reliable designs. Tests have been conducted in an existing natural pond within NIOT campus with the objective of developing methodology of deployment, design and logistics for suction pile installation and testing of mooring capacity under static pullout. Small size suction piles with varying diameters and lengths have been used in the tests. The tests have been carried out in the natural pond with constant water depth of 1.5 m with the top 1.5 m layer of bed comprising soft marine clay. It is found that pile geometry, aspect ratio and angle of pullout have a significant influence on the response to pullout. As angle of mooring load application changes from vertical to horizontal the reaction offered by the suction pile changes from skin friction to passive soil resistance. Resistance offered by the internal plug of soil is found to vary according to dimension of the anchor piles.

  8. 21 CFR 878.4780 - Powered suction pump.

    Science.gov (United States)

    2010-04-01

    ...) Identification. A powered suction pump is a portable, AC-powered or compressed air-powered device intended to be used to remove infectious materials from wounds or fluids from a patient's airway or respiratory support system. The device may be used during surgery in the operating room or at the patient's bedside...

  9. Time management and nectar flow: flower handling and suction feeding in long-proboscid flies (Nemestrinidae: Prosoeca)

    Science.gov (United States)

    Karolyi, Florian; Morawetz, Linde; Colville, Jonathan F.; Handschuh, Stephan; Metscher, Brian D.; Krenn, Harald W.

    2013-11-01

    A well-developed suction pump in the head represents an important adaptation for nectar-feeding insects, such as Hymenoptera, Lepidoptera and Diptera. This pumping organ creates a pressure gradient along the proboscis, which is responsible for nectar uptake. The extremely elongated proboscis of the genus Prosoeca (Nemestrinidae) evolved as an adaptation to feeding from long, tubular flowers. According to the functional constraint hypothesis, nectar uptake through a disproportionately elongated, straw-like proboscis increases flower handling time and consequently lowers the energy intake rate. Due to the conspicuous length variation of the proboscis of Prosoeca, individuals with longer proboscides are hypothesised to have longer handling times. To test this hypothesis, we used field video analyses of flower-visiting behaviour, detailed examinations of the suction pump morphology and correlations of proboscis length with body length and suction pump dimensions. Using a biomechanical framework described for nectar-feeding Lepidoptera in relation to proboscis length and suction pump musculature, we describe and contrast the system in long-proboscid flies. Flies with longer proboscides spent significantly more time drinking from flowers. In addition, proboscis length and body length showed a positive allometric relationship. Furthermore, adaptations of the suction pump included an allometric relationship between proboscis length and suction pump muscle volume and a combination of two pumping organs. Overall, the study gives detailed insight into the adaptations required for long-proboscid nectar feeding, and comparisons with other nectar-sucking insects allow further considerations of the evolution of the suction pump in insects with sucking mouthparts.

  10. Half versus full vacuum suction drainage after modified radical mastectomy for breast cancer- a prospective randomized clinical trial[ISRCTN24484328

    Directory of Open Access Journals (Sweden)

    Singh JP

    2005-01-01

    Full Text Available Abstract Background Suction drains are routinely used after modified radical mastectomy and are an important factor contributing to increased hospital stay as the patients are often discharged only after their removal. Amongst various factors that influence the amount of postoperative drainage, the negative suction pressure applied to the drain has been reported to be of great significance. While a high negative suction pressure is expected to drain the collection and reduce the dead space promptly, it may also prevent the leaking lymphatics from closing and lead to increased drainage from the wound. Against this background a prospective randomized clinical study was conducted to compare the amount and duration of drainage between a half negative suction and full vacuum suction drainage in patients following modified radical mastectomy. The associated postoperative morbidity was also compared between the two groups. Methods 85 FNAC (fine needle aspiration cytology proven cases of locally advanced breast cancer were randomized. (Using randomly ordered sealed envelops, which were opened immediately before the closure of the wound in to 50 patients with full vacuum suction (pressure = 700 g/m2 and 35 cases in to half vacuum suction drainage (pressure = 350 g/m2 groups. The two groups were comparable in respect of age, weight, and technique of operation and extent of axillary dissection. Surgery was performed by the same surgical team comprising of five surgeons (two senior and three resident surgeons using a standardized technique with electrocautery. External compression dressing was provided over the axilla for first 48 hrs and following that patients were encouraged to do active and passive shoulder exercises. The outcomes measured were postoperative morbidity and the length of hospital stay. Statistical methods used: Descriptive studies were performed with SPSS version 10 and group characteristics were compared using student t-test. Results

  11. Effects of suction-dredging for cockles on non-target fauna in the Wadden Sea

    NARCIS (Netherlands)

    Hiddink, JG

    2003-01-01

    Suction dredging for cockles removes large cockles from tidal flats and may also cause mortality of non-target fauna and make the habitat less suitable for some species. This study examines whether suction dredging for cockles on tidal flats of the Dutch Wadden Sea had affected densities of

  12. Australian fur seals (Arctocephalus pusillus doriferus use raptorial biting and suction feeding when targeting prey in different foraging scenarios.

    Directory of Open Access Journals (Sweden)

    David P Hocking

    Full Text Available Foraging behaviours used by two female Australian fur seals (Arctocephalus pusillus doriferus were documented during controlled feeding trials. During these trials the seals were presented with prey either free-floating in open water or concealed within a mobile ball or a static box feeding device. When targeting free-floating prey both subjects primarily used raptorial biting in combination with suction, which was used to draw prey to within range of the teeth. When targeting prey concealed within either the mobile or static feeding device, the seals were able to use suction to draw out prey items that could not be reached by biting. Suction was followed by lateral water expulsion, where water drawn into the mouth along with the prey item was purged via the sides of the mouth. Vibrissae were used to explore the surface of the feeding devices, especially when locating the openings in which the prey items had been hidden. The mobile ball device was also manipulated by pushing it with the muzzle to knock out concealed prey, which was not possible when using the static feeding device. To knock prey out of this static device one seal used targeted bubble blowing, where a focused stream of bubbles was blown out of the nose into the openings in the device. Once captured in the jaws, prey items were manipulated and re-oriented using further mouth movements or chews so that they could be swallowed head first. While most items were swallowed whole underwater, some were instead taken to the surface and held in the teeth, while being vigorously shaken to break them into smaller pieces before swallowing. The behavioural flexibility displayed by Australian fur seals likely assists in capturing and consuming the extremely wide range of prey types that are targeted in the wild, during both benthic and epipelagic foraging.

  13. Primary Total Knee Replacement: Is Suction a Portal of Infection?

    Science.gov (United States)

    Budnar, Vijaya M; Amirfeyz, Rouin; Ng, Michael; Bannister, Gordon C; Blom, Ashley W

    2009-01-01

    INTRODUCTION Pulsed lavage during a total knee replacement usually leaves a pool of fluid on the surgical drapes. It is common practice to suck away this fluid using the same suction device used intra-operatively. This could be a cause of direct wound contamination. We hypothesised that bacteria contaminate fluid that collects around the foot in total knee replacement surgery and that suction equipment could be a portal of contamination. We also hypothesised that bacterial count in the fluid is lower if chlorhexidine, rather than saline, is used in the pulsed lavage. PATIENTS AND METHODS Forty patients undergoing primary total knee replacement were divided into two groups. The first group had pulsed lavage with normal saline and the second with 0.05% chlorhexidine. RESULTS At the end of the operation, 20 ml of fluid, pooled on the surgical drapes was aspirated and cultured for bacterial growth. None of the fluid samples showed bacterial growth. CONCLUSIONS Suction device used peri-operatively during knee replacement is unlikely to be a cause of wound contamination. Pulsed lavage with normal saline is as effective as lavage with chlorhexidine. PMID:19335972

  14. Magnetohydrodynamic peristaltic motion of a Newtonian fluid through porous walls through suction and injection

    Science.gov (United States)

    Sivaiah, R.; Hemadri Reddy, R.

    2017-11-01

    In this paper, we investigate the peristaltic transport of a conducting Newtonian fluid bounded by permeable walls with suction and injection moving with constant velocity of the wave in the wave frame of reference under the consideration of long wavelength and low Reynolds number. The analytical solution for the velocity field, pressure gradient and the frictional force are obtained. The effect of suction/injection parameter, amplitude ratio and the permeability parameter including slip on the flow quantities are discussed graphically. It is found that the greater the suction/injection parameter, the smaller the pressure rise against the pump works. Further, the pressure rise increases with increasing Magnetic parameter.

  15. Effects of vacuum suctioning and strategic drape tenting on oxygen concentration in a simulated surgical field.

    Science.gov (United States)

    Kung, Theodore A; Kong, Sarah W; Aliu, Oluseyi; Azizi, Jahan; Kai, Salim; Cederna, Paul S

    2016-02-01

    To investigate the isolated and combined effects of vacuum suctioning and strategic drape tenting on oxygen concentration in an experimental setting. Experimental. Clinical simulation center of a university-affiliated hospital. Mannequin simulation of a patient undergoing facial surgery under sedation anesthesia. Supplemental oxygen was delivered via nasal cannula. Vacuum suctioning and strategic drape tenting. The experimental trials entailed measuring oxygen concentration around the nasal cannula continuously either in the presence or absence of a standard operating room vacuum suction system and strategic tenting of surgical drapes. The primary outcome was the time required for oxygen concentration to reach 21%. In the control group (without suction or strategic tenting), a mean time of 180 seconds elapsed until the measured oxygen concentration reached 21% after cessation of oxygen delivery. Use of a vacuum suction device alone (110 seconds; P strategic tenting (110 seconds; P strategic tenting of surgical drapes has a theoretical benefit to decreasing the pooling of oxygen around the surgical site, further investigation is necessary before its routine use is recommended. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. A new suction mask to reduce leak during neonatal resuscitation: a manikin study.

    Science.gov (United States)

    Lorenz, Laila; Maxfield, Dominic A; Dawson, Jennifer A; Kamlin, C Omar F; McGrory, Lorraine; Thio, Marta; Donath, Susan M; Davis, Peter G

    2016-09-01

    Leak around the face mask is a common problem during neonatal resuscitation. A newly designed face mask using a suction system to enhance contact between the mask and the infant's face might reduce leak and improve neonatal resuscitation. The aim of the study is to determine whether leak is reduced using the suction mask (Resusi-sure mask) compared with a conventional mask (Laerdal Silicone mask) in a manikin model. Sixty participants from different professional categories (neonatal consultants, fellows, registrars, nurses, midwives and students) used each face mask in a random order to deliver 2 min of positive pressure ventilation to a manikin. Delivered airway pressures were measured using a pressure line. Inspiratory and expiratory flows were measured using a flow sensor, and expiratory tidal volumes and mask leaks were derived from these values. A median (IQR) leak of 12.1 (0.6-39.0)% was found with the conventional mask compared with 0.7 (0.2-4.6)% using the suction mask (p=0.002). 50% of the participants preferred to use the suction mask and 38% preferred to use the conventional mask. There was no correlation between leak and operator experience. A new neonatal face mask based on the suction system reduced leak in a manikin model. Clinical studies to test the safety and effectiveness of this mask are needed. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  17. Development of Energy Efficiency Design Map based on acoustic resonance frequency of suction muffler in compressor

    International Nuclear Information System (INIS)

    Oh, Seungjae; Wang, Semyung; Cho, Sungman

    2015-01-01

    Highlights: • Development of Energy Efficiency Design Map. • Experimental validation of Energy Efficiency Design Map. • Suggestion regarding the Acoustically Supercharged Energy Efficiency. • Sensitivity analysis of the Energy Efficiency Ratio with respect to acoustic pressure. • Suggestion regarding the hybrid coupling method for acoustic analysis in compressor. - Abstract: The volumetric efficiency of the Internal Combustion (IC) engine and compressor can be increased by properly adjusting the acoustic resonance frequency of the suction muffler or the suction valve timing without any additional equipment or power source. This effect is known as acoustic supercharging. However, the energy efficiency has become more important than the volumetric efficiency because of the energy shortage issue and factors influencing consumers’ purchasing decisions. Therefore, methods for increasing the energy efficiency using the acoustic effect in the suction part of IC engine and compressor should be considered. In this study, a systematic method for improving the energy efficiency using the acoustic effect in the suction part of the compressor used in refrigerators and air conditioners was developed for the first time. This effect is named as the Acoustically Supercharged Energy Efficiency (ASEE). For the ASEE, first, a hybrid coupling method was suggested for the acoustical analysis in the suction part of the compressor. Next, an Energy Efficiency Design Map (EEDM) was proposed. This can serve as a design guide for suction mufflers in terms of the energy efficiency. Finally, sensitivity analyses of the Energy Efficiency Ratio (EER) and total massflow rate with respect to the acoustic pressure were conducted to identify the relationship between the acoustic pressure and the suction valve motion. This provides the physical background for the EEDM

  18. Final Report: Summary of Findings and Recommendations for Suction Devices for Management of Prehospital Combat Casualty Care Injuries

    Science.gov (United States)

    2017-11-13

    Airway Final Report: Summary of Findings and Recommendations for Suction Devices for Management of Prehospital Combat Casualty Care Injuries...Consumer Style Comparison Table of Suction Pump Devices ............................. 103 Appendix H – Web Links for Images for Consumer- Style ...0022 pg. 6 Executive Summary Suction is a critical component of airway management , which is the second leading cause of preventable

  19. COMPARISON OF THE EFFECTIVENESS OF TWO LEVELS OF SUCTION PRESSURE ON OXYGEN SATURATION IN PATIENTS WITH ENDOTRACHEAL TUBE

    Directory of Open Access Journals (Sweden)

    Muhaji

    2017-12-01

    Full Text Available Background: Endotracheal suctioning is one of the common supportive measures in intensive care units (ICU, which may be related to complications such as hypoxia. However, a questionable efficacy is still identified to choose suctioning pressure between 130 mmHg and 140 mmHg that is effective for patients with endotracheal tube. Objective: To compare the effectiveness of 130 mmHg and 140 mmHg suctioning pressure on oxygen saturation in patients with endotracheal tube. Methods: This research used a quasy experimental design with pretest and posttest group. The study was conducted from 31 January to 1 March 2017 in the Hospital of Panti Wilasa Citarum and Hospital of Roemani Muhammadiyah Semarang. There were 30 samples recruited using consecutive sampling, with 15 assigned in the 130 mmHg and 140 mmHg suctioning pressure group. Pulse oximetry was used to measure oxygen saturation. Paired t-test and Independent t-test were used for data analysis. Results: Findings showed that there was a statistically significant effect of 130 and 140 mmHg suctioning pressure on oxygen saturation in patients with ETT with p-value <0.05. There was a significant mean difference of oxygen saturation between 130 mmHg and 140 mmHg suctioning pressure group with p-value 0.004 (<0.05. The mean difference of oxygen saturation between both groups was 13.157. Conclusion: The 140 mmHg suctioning pressure is more effective compared with 130 mmHg suctioning pressure in increasing oxygen saturation in patients with ETT.

  20. External Suction and Fluid Output in Chest Drains After Lobectomy

    DEFF Research Database (Denmark)

    Lijkendijk, Marike; Neckelmann, Kirsten; Licht, Peter B

    2018-01-01

    influences the amount of fluid. METHODS: We randomly assigned (1:1) 106 patients who underwent lobectomy to either low (-5 cm H2O) or high (-20 cm H2O) external suction using an electronic chest drainage system. Only one chest drain was allowed, and we used strict algorithms for chest drain removal, which...... was delegated to staff nurses: air leakage less than 20 mL/min for 6 hours regardless of fluid output, provided it was serous. The primary end point was fluid output after 24 and 48 hours. RESULTS: Mean fluid output was significantly higher with high suction after both 24 (338 ± 265 mL versus 523 ± 215 m...

  1. Structural Optimization of an Offshore Wind Turbines Transition Pieces for Bucket Foundations

    DEFF Research Database (Denmark)

    Nezhentseva, Anastasia; Andersen, Lars Vabbersgaard; Ibsen, Lars Bo

    Traditionally, offshore constructions are made of steel. The focus of this paper is optimization of a transition piece (TP) connecting the offshore wind turbine column with a suction bucket foundation. Suction caissons, typically used for shallow water depths, have been proved to be adequate...... in residual soil conditions for depths up to approximately 40 m. The existing design practice is limited to the use of steel-flange-reinforced shear panels. Desirable outcome is proposal of an alternative material which does not require extensive welding work. Compact reinforced composite (CRC) is suggested...... curved segments have been introduced between the conical part and the tubular parts of the structure. While the minimum amount of steel and concrete was required for the composite CRC–steel shell model, the pure CRC model appeared to be the least sensitive to geometrical imperfections, corresponding...

  2. Vortex cavitation and oscillation in a double-suction volute pump

    International Nuclear Information System (INIS)

    Sato, T; Nagahara, T; Tanaka, K; Fuchiwaki, M; Shimizu, F

    2010-01-01

    In recent years, Computational Fluid Dynamics (CFD) codes have been utilized actively in the early part of the product development cycle. Numerical analysis models have also been developed rapidly and have added cavitation flow analysis functions peculiar to hydraulic machines, in which the flow analysis has been developed remarkably with high-precision and high-reliability. On the other hand, it is well known that three kinds of cavitation, such as vortex cavitation, reverse flow cavitation and cloud cavitation appear in a double-suction volute pump. We have much interest in a relationship among the cavitating flows, pump oscillation and noise. In this study, full 3D numerical simulations have been performed using a commercial code inside the pump from the inlet of suction duct to the outlet of delivery duct. The numerical model is based on a combination of multiphase flow equations with the truncated version of the Rayleigh-Plesset model predicting the complicated growth and collapse process of cavity bubbles. This study highlights especially the mechanism of vortex cavitation occurrence from the end of the suction duct in the pump and pump oscillation which causes cavitation noise from the pump. The experimental investigations have also been performed on the cavitating flow with flow visualization to evaluate the numerical results.

  3. A Macro-Element Approach for Non-linear Response of Offshore Skirted Footings

    DEFF Research Database (Denmark)

    Barari, Amin; Ibsen, Lars Bo

    2018-01-01

    -hardening plasticity model for the moment and horizontal force resultants associated with the displacements of the offshore suction caissons is herein developed. In addition, in order to better understand the performance of offshore bucket foundations under cyclic lateral loads series of cyclic lateral load tests were...... carried out on small scale models in a special rig developed for the cyclic tests at Aalborg University. The influence of cyclic lateral loads on the bucket lateral secant stiffness is investigated and a function is utilized to investigate it due to permanent displacements. The bucket stiffness increased...

  4. Supermarket refrigeration. Optimization of suction pressure in existing refrigerators; Supermarktkaelte. Saugdruck optimieren in Bestandskaelteanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Philipp; Mueller, Markus [Eckelmann AG, Wiesbaden (Germany)

    2012-06-15

    The new E*LDS firmware E*COP{sup +} from Eckelmann AG (Wiesbaden, Federal Republic of Germany) for the optimization of the suction pressure supplies a demand-oriented adaptation of the suction pressure. The new feature is ideal for an update of existing systems with thermostatic expansion valves. Using this update operators of supermarket operators may save about 10% energy with little effort.

  5. Natural convection boundary layer with suction and mass transfer in a porous medium

    International Nuclear Information System (INIS)

    Bestman, A.R.

    1989-03-01

    The free convection boundary layer flow with simultaneous heat and mass transfer in a porous medium is studied when the boundary wall moves in its own plane with suction. The study also incorporates chemical reaction for the very simple model of a binary reaction with Arrhenius activation energy. For large suction asymptotic approximate solutions are obtained for the flow variables for various values of the activation energy. (author). 10 refs, 2 figs

  6. The effect of intraoral suction on oxygen-enriched surgical environments: a mechanism for reducing the risk of surgical fires.

    Science.gov (United States)

    VanCleave, Andrea M; Jones, James E; McGlothlin, James D; Saxen, Mark A; Sanders, Brian J; Vinson, LaQuia A

    2014-01-01

    In this study, a mechanical model was applied in order to replicate potential surgical fire conditions in an oxygen-enriched environment with and without high-volume suction typical for dental surgical applications. During 41 trials, 3 combustion events were measured: an audible pop, a visible flash of light, and full ignition. In at least 11 of 21 trials without suction, all 3 conditions were observed, sometimes with an extent of fire that required early termination of the experimental trial. By contrast, in 18 of 20 with-suction trials, ignition did not occur at all, and in the 2 cases where ignition did occur, the fire was qualitatively a much smaller, candle-like flame. Statistically comparing these 3 combustion events in the no-suction versus with-suction trials, ignition (P = .0005), audible pop (P = .0211), and flash (P = .0092) were all significantly more likely in the no-suction condition. These results suggest a possible significant and new element to be added to existing surgical fire safety protocols toward making surgical fires the "never-events" they should be.

  7. CAISSON: Interconnect Network Simulator

    Science.gov (United States)

    Springer, Paul L.

    2006-01-01

    Cray response to HPCS initiative. Model future petaflop computer interconnect. Parallel discrete event simulation techniques for large scale network simulation. Built on WarpIV engine. Run on laptop and Altix 3000. Can be sized up to 1000 simulated nodes per host node. Good parallel scaling characteristics. Flexible: multiple injectors, arbitration strategies, queue iterators, network topologies.

  8. Endoscopic en bloc resection of an exophytic gastrointestinal stromal tumor with suction excavation technique

    Science.gov (United States)

    Choi, Hyuk Soon; Chun, Hoon Jai; Kim, Kyoung-Oh; Kim, Eun Sun; Keum, Bora; Jeen, Yoon-Tae; Lee, Hong Sik; Kim, Chang Duck

    2016-01-01

    Here, we report the first successful endoscopic resection of an exophytic gastrointestinal stromal tumor (GIST) using a novel perforation-free suction excavation technique. A 49-year-old woman presented for further management of a gastric subepithelial tumor on the lesser curvature of the lower body, originally detected via routine upper gastrointestinal endoscopy. Abdominal computed tomography and endoscopic ultrasound showed a 4-cm extraluminally protruding mass originating from the muscularis propria layer. The patient firmly refused surgical resection owing to potential cardiac problems, and informed consent was obtained for endoscopic removal. Careful dissection and suction of the tumor was repeated until successful extraction was achieved without serosal injury. We named this procedure the suction excavation technique. The tumor’s dimensions were 3.5 cm × 2.8 cm × 2.5 cm. The tumor was positive for C-KIT and CD34 by immunohistochemical staining. The mitotic count was 6/50 high-power fields. The patient was followed for 5 years without tumor recurrence. This case demonstrated the use of endoscopic resection of an exophytic GIST using the suction excavation technique as a potential therapy without surgical resection. PMID:27340363

  9. Theoretical Analysis of Effects of Wall Suction on Entropy Generation Rate in Laminar Condensate Layer on Horizontal Tube

    Directory of Open Access Journals (Sweden)

    Tong-Bou Chang

    2014-01-01

    Full Text Available The effects of wall suction on the entropy generation rate in a two-dimensional steady film condensation flow on a horizontal tube are investigated theoretically. In analyzing the liquid flow, the effects of both the gravitational force and the viscous force are taken into account. In addition, a film thickness reduction ratio, Sf, is introduced to evaluate the effect of wall suction on the thickness of the condensate layer. The analytical results show that, the entropy generation rate depends on the Jakob number Ja, the Rayleigh number Ra, the Brinkman number Br, the dimensionless temperature difference ψ, and the wall suction parameter Sw. In addition, it is shown that in the absence of wall suction, a closed-form correlation for the Nusselt number can be derived. Finally, it is shown that the dimensionless entropy generation due to heat transfer, NT, increases with an increasing suction parameter Sw, whereas the dimensionless entropy generation due to liquid film flow friction, NF, decreases.

  10. LES-based characterization of a suction and oscillatory blowing fluidic actuator

    Science.gov (United States)

    Kim, Jeonglae; Moin, Parviz

    2015-11-01

    Recently, a novel fluidic actuator using steady suction and oscillatory blowing was developed for control of turbulent flows. The suction and oscillatory blowing (SaOB) actuator combines steady suction and pulsed oscillatory blowing into a single device. The actuation is based upon a self-sustained mechanism of confined jets and does not require any moving parts. The control output is determined by a pressure source and the geometric details, and no additional input is needed. While its basic mechanisms have been investigated to some extent, detailed characteristics of internal turbulent flows are not well understood. In this study, internal flows of the SaOB actuator are simulated using large-eddy simulation (LES). Flow characteristics within the actuator are described in detail for a better understanding of the physical mechanisms and improving the actuator design. LES predicts the self-sustained oscillations of the turbulent jet. Switching frequency, maximum velocity at the actuator outlets, and wall pressure distribution are in good agreement with the experimental measurements. The computational results are used to develop simplified boundary conditions for numerical experiments of active flow control. Supported by the Boeing company.

  11. Fluid Model of Sliding Suction Cup of Wall-climbing Robots

    Directory of Open Access Journals (Sweden)

    Fu Zhuang

    2008-11-01

    Full Text Available The adhering capability, one of the most important performance indexes of wall-climbing robots(WCRs, should be taken into account when a WCR is designed. This paper proposes a novel approach for investigating the adhering characteristics of the sliding suction cup (SSCs using fluid network theory to enhance the adhering capability of WCRs. The fluid models of the SSCs of two WCRs are developed and equivalent circuits in three cases are presented. The dynamic responses of negative pressure in SSCs are obtained and validated by a set of experiments. It indicated that the theoretical analysis is reasonable and can give some valuable design criteria on the structure parameters of SSCs and control strategies of suction force of SSCs.

  12. The effects of suction and pin/lock suspension systems on transtibial amputees' gait performance.

    Directory of Open Access Journals (Sweden)

    Hossein Gholizadeh

    Full Text Available BACKGROUND: The suction sockets that are commonly prescribed for transtibial amputees are believed to provide a better suspension than the pin/lock systems. Nevertheless, their effect on amputees' gait performance has not yet been fully investigated. The main intention of this study was to understand the potential effects of the Seal-in (suction and the Dermo (pin/lock suspension systems on amputees' gait performance. METHODOLOGY/PRINCIPAL FINDINGS: Ten unilateral transtibial amputees participated in this prospective study, and two prostheses were fabricated for each of them. A three-dimensional motion analysis system was used to evaluate the temporal-spatial, kinematics and kinetics variables during normal walking. We also asked the participants to complete some part of Prosthesis Evaluation Questionnaire (PEQ regarding their satisfaction and problems with both systems. The results revealed that there was more symmetry in temporal-spatial parameters between the prosthetic and sound limbs using the suction system. However, the difference between two systems was not significant (p<0.05. Evaluation of kinetic data and the subjects' feedback showed that the participants had more confidence using the suction socket and the sockets were more fit for walking. Nevertheless, the participants had more complaints with this system due to the difficulty in donning and doffing. CONCLUSION: It can be concluded that even though the suction socket could create better suspension, fit, and gait performance, overall satisfaction was higher with the pin/lock system due to easy donning and doffing of the prosthesis. TRIAL REGISTRATION: irct.ir IRCT2014012816395N1.

  13. Numerical Study of Piping Limits for Suction Installation of Offshore Skirted Foundations an Anchors in Layered Sand

    DEFF Research Database (Denmark)

    Ibsen, Lars Bo; Thilsted, C. L.

    2010-01-01

    Skirted foundations and anchors have proved to be competitive solutions for various types of fixed offshore platforms, subsea systems and an attractive foundation alternative for offshore wind turbines. One main design challenge for skirted structures in sand is to penetrate the skirted deep enough...... to obtain the required capacity. In order to overcome the high penetration resistance in sand suction assisted penetration is needed. Suction installation may cause the formation of piping channels, which break down the hydraulic seal and prevent further installation. This paper presents a numerical study...... of failure limits during suction installation in respect to both homogenous and layered soil profile. A numerical flow analysis is performed to determine the hydraulic gradients developing in response to the suction applied, and the results are presented as simple closed form solutions useful for evaluation...

  14. Reduction of the suction losses through reed valves in hermetic reciprocating compressors using a magnet coil

    Science.gov (United States)

    Hopfgartner, J.; Posch, S.; Zuber, B.; Almbauer, R.; Krischan, K.; Stangl, S.

    2017-08-01

    Reed valves are widely used in hermetic reciprocating compressors and are responsible for a large part of the thermodynamic losses. Especially, the suction valve, which is opened nearly during the whole suction stroke, has a big potential for improvement. Usually, suction valves are opened only by vacuum created by the moving piston and should be closed before the compression stroke starts to avoid a reversed mass-flow through the valve. Therefore, the valves are prestressed, which results on the other hand in a higher flow resistance. In this work, a suction valve is investigated, which is not closed by the preload of the valve but by an electromagnetic coil located in the suction muffler neck. Shortly before the piston reaches its bottom dead centre, voltage is applied to the coil and a magnetic force is generated which pulls the valve shut. Thereby, the flow resistance through the valve can be reduced by changing the preload on the reed valve because it is no longer needed to close the valve. The investigation of this adapted valve and the electromagnetic coil is firstly done by numerical simulations including fluid structure interactions of the reed valves of a reciprocating compressor and secondly by experiments made on a calorimeter test bench.

  15. Influence of saturation degree and role of suction in unsaturated soils behaviour: application to liquefaction

    Directory of Open Access Journals (Sweden)

    Vernay Mathilde

    2016-01-01

    Full Text Available The effect of the pore fluid compressibility on liquefaction has been studied by various authors. But few papers have been published about the role of suction in cyclic behavior of unsaturated soils. Most of these works use Skempton coefficient B as a reference in terms of saturation degree to analyze their results. The use of B in experimental conditions is convenient, but is not accurate when studying liquefaction behavior, since effects of suction are neglected. In this paper, the influence of saturation degree on mechanical behavior of a soil under dynamic loads is studied. Cyclic undrained triaxial tests were performed on sand samples, under various levels of saturation. Soil-water characteristic curve was used, in order to study influence of suction. The first results confirm that when the degree of saturation decreases, the resistance increases. Initial positive suction tends to stiffen the soil. It also appears that the presence of air delays the occurrence of liquefaction, but doesn’t prevent it. Indeed, liquefaction is observed, whether the soil is saturated or not.

  16. Gravity separation of pericardial fat in cardiotomy suction blood: an in vitro model.

    Science.gov (United States)

    Kinard, M Rhett; Shackelford, Anthony G; Sistino, Joseph J

    2009-06-01

    Fat emboli generated during cardiac surgery have been shown to cause neurologic complications in patients postoperatively. Cardiotomy suction has been known to be a large generator of emboli. This study will examine the efficacy of a separation technique in which the cardiotomy suction blood is stored in a cardiotomy reservoir for various time intervals to allow spontaneous separation of fat from blood by density. Soybean oil was added to heparinized porcine blood to simulate the blood of a patient with hypertriglyceridemia (> 150 mg/dL). Roller pump suction was used to transfer the room temperature blood into the cardiotomy reservoir. Blood was removed from the reservoir in 200-mL aliquots at 0, 15, 30 45, and 60 minutes. Samples were taken at each interval and centrifuged to facilitate further separation of liquid fat. Fat content in each sample was determined by a point-of-care triglyceride analyzer. Three trials were conducted for a total of 30 samples. The 0-minute group was considered a baseline and was compared to the other four times. Fat concentration was reduced significantly in the 45- and 60-minute groups compared to the 0-, 15-, and 30-minute groups (p Gravity separation of cardiotomy suction blood is effective; however, it may require retention of blood for more time than is clinically acceptable during a routing coronary artery bypass graft surgery.

  17. 78 FR 20316 - Final Issuance of General NPDES Permits (GP) for Small Suction Dredges in Idaho

    Science.gov (United States)

    2013-04-04

    ... System (NPDES) General Permit (IDG-37-0000) to placer mining operations in Idaho for small suction... Small Suction Dredges in Idaho AGENCY: Environmental Protection Agency, Region 10. ACTION: Final notice... significant economic impact on a substantial number of small entities.'' EPA has concluded that NPDES general...

  18. Development of advanced stability theory suction prediction techniques for laminar flow control. [on swept wings

    Science.gov (United States)

    Srokowski, A. J.

    1978-01-01

    The problem of obtaining accurate estimates of suction requirements on swept laminar flow control wings was discussed. A fast accurate computer code developed to predict suction requirements by integrating disturbance amplification rates was described. Assumptions and approximations used in the present computer code are examined in light of flow conditions on the swept wing which may limit their validity.

  19. A Report on Deliverable Three: Determine a Standard Performance Test for Military Suction Device Use

    Science.gov (United States)

    2017-09-20

    evaluating device suction while either wetted or completely immersed is highly important to predict performance in battlefield scenarios. Summary...mechanical, electrical, and environmental. OBJECTIVE: Research and review current test methods outlined in ISO 10079 and published journal articles...of contemporary oropharyngeal suction. The American journal of emergency medicine 17, 611- 613 (1999). 4. Hodgetts, T., Mahoney, P., Evans, G

  20. The use of IV-tubing as a closed-suction drainage system during neurosurgical cases in Tanzania.

    Science.gov (United States)

    Bonfield, Christopher M; Shabani, Hamisi K; Kanumba, Emmanuel S; Ellegala, Dilantha B; Nicholas, Joyce

    2013-01-01

    Commercial closed-suctions drainage systems are commonly used in the United States and many other countries for use in neurosurgical cases. However, in Tanzania and other developing nations with fewer resources, these are not available. This report explores another option for a closed-system drainage system utilizing inexpensive supplies found commonly in hospitals around the world. Sterile IV-tubing is cut, inserted into the wound, and brought out through an adjacent puncture incision. For suction, an empty plastic bottle can be attached to the tubing. The IV-tubing closed-suction drainage system was applied in both cranial and spinal neurosurgical procedures, including as subdural, subgaleal, epidural, and suprafacial drains. It maintained suction and was an adequate substitute when commercial drains are unavailable. This report illustrates how sterile IV-tubing can be adapted for use as a closed-drainage system. It utilizes inexpensive supplies commonly found in many hospitals throughout the world and can be applied to both cranial and spinal neurosurgical procedures.

  1. Deriving the suction stress of unsaturated soils from water retention curve, based on wetted surface area in pores

    Science.gov (United States)

    Greco, Roberto; Gargano, Rudy

    2016-04-01

    The evaluation of suction stress in unsaturated soils has important implications in several practical applications. Suction stress affects soil aggregate stability and soil erosion. Furthermore, the equilibrium of shallow unsaturated soil deposits along steep slopes is often possible only thanks to the contribution of suction to soil effective stress. Experimental evidence, as well as theoretical arguments, shows that suction stress is a nonlinear function of matric suction. The relationship expressing the dependence of suction stress on soil matric suction is usually indicated as Soil Stress Characteristic Curve (SSCC). In this study, a novel equation for the evaluation of the suction stress of an unsaturated soil is proposed, assuming that the exchange of stress between soil water and solid particles occurs only through the part of the surface of the solid particles which is in direct contact with water. The proposed equation, based only upon geometric considerations related to soil pore-size distribution, allows to easily derive the SSCC from the water retention curve (SWRC), with the assignment of two additional parameters. The first parameter, representing the projection of the external surface area of the soil over a generic plane surface, can be reasonably estimated from the residual water content of the soil. The second parameter, indicated as H0, is the water potential, below which adsorption significantly contributes to water retention. For the experimental verification of the proposed approach such a parameter is considered as a fitting parameter. The proposed equation is applied to the interpretation of suction stress experimental data, taken from the literature, spanning over a wide range of soil textures. The obtained results show that in all cases the proposed relationships closely reproduces the experimental data, performing better than other currently used expressions. The obtained results also show that the adopted values of the parameter H0

  2. Finite element simulation of moisture movement and solute transport in a large caisson

    International Nuclear Information System (INIS)

    Huyakorn, P.S.; Jones, B.G.; Parker, J.C.; Wadsworth, T.D.; White, H.O. Jr.

    1987-01-01

    The results of the solute transport experiments performed on compacted, crushed Bandelier Tuff in caisson B of the experimental cluster described by DePoorter (1981) are simulated. Both one- and three-dimensional simulations of solute transport have been performed using two selected finite element codes. Results of bromide and iodide tracer experiments conducted during near-steady flow conditions have been analyzed for pulse additions made on December 6, 1984, and followed over a period of up to 60 days. In addition, a pulse addition of nonconservative strontium tracer on September 28, 1984, during questionably steady flow conditions has been analyzed over a period of 240 days. One-dimensional finite element flow and transport simulations were carried out assuming the porous medium to be homogeneous and the injection source uniformly distributed. To evaluate effects of the nonuniform source distribution and also to investigate effects of inhomogeneous porous medium properties, three dimensional finite element analyses of transport were carried out. Implications of the three-dimensional effects for the design and analysis of future tracer studies are discussed

  3. Experimental study on occurrence-time ratio measurements of air entrainment in a suction sump

    International Nuclear Information System (INIS)

    Inagaki, K; Funaki, J; Hirata, K

    2009-01-01

    In order to get accurate measurements of air entrainment in a suction sump, we design some new simple bubble sensors, which can detect the existence of air bubbles inside a suction pipe with no disturbances by the sensors and with a fine spatial resolution. We force on an intermittency factor γ, that is, an occurrence-time ratio of the air entrainment, and compare the result by the present sensor with those by conventional two methods; namely, visual and auditory ones. As a result, we show the criteria which specify lower-accuracy conditions in the conventional methods. By the visual method, the accuracy of the γ becomes low, when γ is less than 0.05. By the auditory method, the accuracy of γ becomes low, when the submergence depth S of the suction pipe is close to the critical one S c .

  4. Improved Suction Technique for the Characterization of Construction Materials

    DEFF Research Database (Denmark)

    Thygesen, Lisbeth Garbrecht; Hansen, Kurt Kielsgaard

    2007-01-01

    The suction technique is a method from soil science that is used for the study of moisture storage capacity in porous construction materials at high relative humidity levels (above approximately 93%). The samples to be studied are placed in a pressurized container (an extractor) on a water...

  5. Material Composition of Bucket Foundation Transition Piece for Offshore Wind Turbines

    DEFF Research Database (Denmark)

    Nezhentseva, Anastasia; Andersen, Lars; Ibsen, Lars Bo

    2010-01-01

    In Denmark, production of renewable energy is focused on offshore wind turbines, since they make little if any inconvenience for residents in inhabited areas. High requirements are placed on the installation of the foundations which can cost about 30% of the total cost of the wind turbine....... This paper deals with the transition piece for a relatively novel type of foundation, the so-called suction bucket (caisson), focusing on the design of a transition piece connecting the turbine column with a suction bucket used as a monopod foundation for an offshore wind turbine. Since the current design...... practice is limited to the use of steel-flange-reinforced shear panels for the transition piece—a production that requires extensive welding work—a desirable solution is to find a material that provides lower cost and easier manufacturing without compromising the strength and stiffness. The paper compares...

  6. Radon Sub-slab Suctioning System Integrated in Insulating Layer

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    2013-01-01

    This poster presents a new radon sub-slab suctioning system. This system makes use of a grid of horizontal pressurised air ducts located within the lower part of the rigid insulation layer of the ground floor slab. For this purpose a new system of prefabricated lightweight elements is introduced...

  7. A Constitutive Model for Unsaturated soils based on a Compressibility Framework dependent on Suction and Degree of Saturation

    Directory of Open Access Journals (Sweden)

    Sitarenios Panagiotis

    2016-01-01

    Full Text Available The Modified Cam Clay model is extended to account for the behaviour of unsaturated soils using Bishop’s stress. To describe the Loading – Collapse behaviour, the model incorporates a compressibility framework with suction and degree of saturation dependent compression lines. For simplicity, the present paper describes the model in the triaxial stress space with characteristic simulations of constant suction compression and triaxial tests, as well as wetting tests. The model reproduces an evolving post yield compressibility under constant suction compression, and thus, can adequately describe a maximum of collapse.

  8. Numerical Investigation of Wall Cooling and Suction Effects on Supersonic Flat-Plate Boundary Layer Transition Using Large Eddy Simulation

    Directory of Open Access Journals (Sweden)

    Suozhu Wang

    2015-02-01

    Full Text Available Reducing friction resistance and aerodynamic heating has important engineering significance to improve the performances of super/hypersonic aircraft, so the purpose of transition control and turbulent drag reduction becomes one of the cutting edges in turbulence research. In order to investigate the influences of wall cooling and suction on the transition process and fully developed turbulence, the large eddy simulation of spatially evolving supersonic boundary layer transition over a flat-plate with freestream Mach number 4.5 at different wall temperature and suction intensity is performed in the present work. It is found that the wall cooling and suction are capable of changing the mean velocity profile within the boundary layer and improving the stability of the flow field, thus delaying the onset of the spatial transition process. The transition control will become more effective as the wall temperature decreases, while there is an optimal wall suction intensity under the given conditions. Moreover, the development of large-scale coherent structures can be suppressed effectively via wall cooling, but wall suction has no influence.

  9. Analysis of Infiltration-Suction Response in Unsaturated Residual Soil Slope in Gelugor, Penang

    Science.gov (United States)

    Ashraf Mohamad Ismail, Mohd; Hasliza Hamzah, Nur; Min, Ng Soon; Hazreek Zainal Abidin, Mohd; Tajudin, Saiful Azhar Ahmad; Madun, Aziman

    2018-04-01

    Rainfall infiltration on residual soil slope may impair slope stability by altering the pore-water pressure in the soil. A study has been carried out on unsaturated residual soil slope in Gelugor, Penang to determine the changes in matric suction of residual soils at different depth due to rainwater infiltration. The sequence of this study includes the site investigation, field instrumentation, laboratory experiment and numerical modeling. Void ratio and porosity of soil were found to be decreasing with depth while the bulk density and dry density of soil increased due to lower porosity of soil at greater depth. Soil infiltration rate and matric suction of all depths decrease with the increase of volumetric water content as well as the degree of saturation. Numerical modeling was used to verify and predict the relationship between infiltration-suction response and degree of saturation. Numerical models can be used to integrate the rainfall scenarios into quantitative landslide hazard assessments. Thus, development plans and mitigation measures can be designed for estimated impacts from hazard assessments based on collected data.

  10. Frequency Response of Near-Wall Coherent Structures to Localized Periodic Blowing and Suction in Turbulent Boundary Layer

    International Nuclear Information System (INIS)

    Jian-Hua, Liu; Nan, Jiang

    2008-01-01

    We experimentally investigate the frequency response of near-wall coherent structures to localized periodic blowing and suction through a spanwise slot in a turbulent boundary layer by changing the frequency of periodic disturbance at similar velocities of free stream. The effects of blowing and suction disturbance on energy redistribution, turbulent intensity u' rms + , over y + and waveforms of phase-averaged velocity during sweeping process are respectively discussed under three frequencies of periodic blowing and suction in near-wall region of turbulent boundary layer, compared with those in a standard turbulent boundary layer. The most effective disturbance frequency is figured out in this system. (fundamental areas of phenomenology (including applications))

  11. MHD flow over a permeable stretching/shrinking sheet of a nanofluid with suction/injection

    Directory of Open Access Journals (Sweden)

    Sandeep Naramgari

    2016-06-01

    Full Text Available In this study we analyzed the influence of thermal radiation and chemical reaction on two dimensional steady magnetohydrodynamic flow of a nanofluid past a permeable stretching/shrinking sheet in the presence of suction/injection. We considered nanofluid volume fraction on the boundary is submissive controlled, which makes the present study entirely different from earlier studies and physically more realistic. The equations governing the flow are solved numerically. Effects of non-dimensional governing parameters on velocity, temperature and concentration profiles are discussed and presented through graphs. Also, coefficient of skin friction and local Nusselt number is investigated for stretching/shrinking and suction/injection cases separately and presented through tables. Comparisons with existed results are presented. Present results have an excellent agreement with the existed studies under some special assumptions. Results indicate that the enhancement in Brownian motion and thermophoresis parameters depreciates the nanoparticle concentration and increases the mass transfer rate. Dual solutions exist only for certain range of stretching/shrinking and suction/injection parameters.

  12. Tube suction test for evaluating durability of cementitiously stabilized soils.

    Science.gov (United States)

    2011-06-01

    In a comprehensive laboratory study, different tests namely, unconfined compressive strength (UCS) at the end of freeze-thaw/wet-dry (F-T/W-D) cycles, resilient modulus (Mr) at the end of F-T/W-D cycles, vacuum saturation, tube suction, and moisture ...

  13. Tube suction test for evaluating durability of cementitiously stabilized soils.

    Science.gov (United States)

    2011-06-01

    In a comprehensive laboratory study, different tests namely, unconfined compressive strength (UCS) at the end of freeze-thaw/wet-dry (FT/ : W-D) cycles, resilient modulus (Mr) at the end of F-T/W-D cycles, vacuum saturation, tube suction, and moistur...

  14. Safety System for Controlling Fluid Flow into a Suction Line

    Science.gov (United States)

    England, John Dwight (Inventor); Kelley, Anthony R. (Inventor); Cronise, Raymond J. (Inventor)

    2018-01-01

    A safety system includes a sleeve fitted within a pool's suction line at its inlet. The sleeve terminates with a plate that resides within the suction line. The plate has holes formed therethrough. A housing defining distinct channels is fitted in the sleeve so that the distinct channels lie within the sleeve. Each of the distinct channels has a first opening on one end thereof and a second opening on another end thereof. The second openings reside in the sleeve. The first openings are in fluid communication with the water in the pool, and are distributed around a periphery of an area of the housing that prevents coverage of all the first openings when a human interacts therewith. A first sensor is coupled to the sleeve to sense pressure therein, and a second pressure sensor is coupled to the plate to sense pressure in one of the plates' holes.

  15. Vapor pressure lowering effects due to salinity and suction pressure in the depletion of vapor-dominated geothermal reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Battistelli, A. [Aquater S.p.A., Pisa (Italy); Calore, C. [Istituto Internazionale per le Ricerche Geotermiche-CNR, Pisa (Italy); Pruess, K. [Lawrence Berkeley Lab., Berkeley, CA (United States)

    1995-03-01

    The equation-of-state module able to handle saline brines with non-condensible gas, developed for the TOUGH2 simulator, has been improved to include vapor pressure lowering (VPL) due to suction pressure as represented by Kelvin`s equation. In this equation the effects of salt are considered whereas those of non-condensible gas have currently been neglected. Numerical simulations of fluid production from tight matrix blocks have been performed to evaluate the impact of VPL effects due to salinity and suction pressure on the depletion behaviour of vapor-dominated geothermal reservoirs. Previous studies performed neglected VPL due to suction pressure showed that for initial NaCl mass fractions above threshold values, {open_quotes}sealing{close_quotes} of the block occurs and large amounts of liquid fluid may not be recovered. On the other hand, below the threshold value the matrix block dries out due to fluid production. The inclusion of VPL due to suction pressure does not allow complete vaporization of the liquid phase. As a result, the threshold NaCl concentration above which sealing of the matrix block occurs is increased. Above the {open_quotes}critical{close_quotes} NaCl concentration, block depletion behaviour with and without the VPL due to suction pressure is almost identical, as liquid phase saturation remains high even after long production times. As the VPL due to suction pressure depends mainly on capillary pressure, the shape of capillary pressure functions used in numerical simulations is important in determining VPL effects on block depletion.

  16. Research on partial coefficients for design of quarter-circular caisson breakwater

    Science.gov (United States)

    Qie, Luwen; Zhang, Xiang; Jiang, Xuelian; Qin, Yinan

    2013-03-01

    The quarter-circular caisson breakwater (QCB) is a new type of breakwater, and it can be applied in deepwater. The stability of QCB under wave force action can be enhanced, and the rubble mound engineering can be less than that of semi-circular breakwaters in deepwater. In order to study the wave force distribution acting on the QCB, to find wave force formula for this type of breakwater, firstly in this paper, the distribution characteristics of the horizontal force, the downward vertical force and the uplift force on the breakwater were gotten based on physical model wave flume experiments and on the analysis of the wave pressure experimental data. Based on a series of physical model tests acted by irregular waves, a kind of calculation method, which was modified by Goda formula, was proposed to carry out the wave force on the QCB. Secondly, the reliability method with correlated variables was adopted to analyze the QCB, considering the high correlation between wave forces or moments. Utilizing the observed wave data in engineering field, the reliability index and failure probability of QCB were obtained. Finally, a factor Q=0.9 is given to modify the zero pressure height above SWL of QCB, and wave force partial coefficient 1.34 to the design expressions of QCB for anti-sliding, as well as 1.67 for anti-overturning, were presented.

  17. Timer switch to convert suction apparatus for negative pressure wound therapy application

    Directory of Open Access Journals (Sweden)

    Surath Amarnath

    2014-01-01

    Full Text Available Background: Negative pressure wound therapy (NPWT is an established modality in the treatment of chronic wounds, open fractures, and post-operative wound problems. This method has not been widely used due to the high cost of equipment and consumables. This study demonstrates an indigenously developed apparatus which gives comparable results at a fraction of the cost. Readily available materials are used for the air-tight dressing. Materials and Methods: Equipment consists of suction apparatus with adjustable pressure valve set to a pressure 125-150 mmHg. An electronic timer switch with a sequential working time of 5 min and a standby time of 3 min provides the required intermittent negative pressure. Readily available materials such as polyvinyl alcohol sponge, suction drains and steridrapes were used to provide an air tight wound cover. Results: A total of 90 cases underwent 262 NPWT applications from 2009 to 2014. This series, comprised of 30 open fractures, 21 post-operative and 39 chronic wounds. The wound healing rate in our study was comparable to other published studies using NPWT. Conclusion: The addition of electronic timer switch will convert a suction apparatus into NPWT machine, and the results are equally effective compared to more expensive counter parts. The use of indigenous dressing materials reduces the cost significantly.

  18. A Comparison of delO18 Composition of Water Extracted from Suction Lysimeters, Centrifugation, and Azeotropic Distillation

    Science.gov (United States)

    Figueroa, A.; Tindall, J. A.; Friedel, M. J.

    2005-12-01

    Concentration of delO18 in water samples extracted by suction lysimeters is compared to samples obtained by methods of centrifugation and azeotropic distillation. Intact soil cores (30 cm diameter by 40 cm height) were extracted from two different sites. Site 1 was rapid infiltration basin number 50, near Altamonte Springs in Seminole County, Florida on properties belonging to the Walt Disney World Resort Complex. Site 2 was the Missouri Management System Evaluation Area (MSEA) near Centralia in Boone County, Missouri. The delO18 water was analyzed on a mass spectrophotometer. Potassium Bromide (KBr) was also used as a tracer and analyzed by ion chromatography. A portion of the data obtained was modeled using CXTFIT. Water collected by centrifugation and azeotropic distillation data were about 2-5% more negative than that collected by suction lysimeter values from the Florida (sandy) soil and about 5-7 % more negative from the Missouri (well structured clay) soil. Results indicate that the majority of soil water in well structured soil is strongly bound to soil grain surfaces and is not easily sampled by suction lysimeters. Also, it is plausible that evaporation caused some delO18 enrichment in the suction lysimeters. Suction lysimeters preferentially sampled water held at lower matric potentials, which may not represent total soil water. In cases where a sufficient volume of water has passed through the soil profile and displaced all previous pore water, suction lysimeters will however collect a representative sample of all the water at that depth interval. It is suggested that for stable isotope studies monitoring precipitation and soil water, suction lysimeters be installed at shallow depths (10 cm). Samples should also be coordinated with precipitation events. The CXTFIT program worked well for Florida soils (a more homogeneous sand), but gave poor performance for Missouri soils (well structured clays) except for deeper depths where clay structure was less

  19. Thopaz Portable Suction Systems in Thoracic Surgery: An end user assessment and feedback in a tertiary unit

    Directory of Open Access Journals (Sweden)

    Cantlin Teresa

    2011-04-01

    Full Text Available Abstract Background Thoracic surgical patients have chest drains inserted to enable re-expansion of lungs, to clear contents from the pleural cavity which sometimes require negative suction. Suction impedes mobility, may have variable suction delivery and increases risk of infection. Assessment of air-leak in conventional drains is not scientific and is subjective. Thopaz chest drain system is a portable suction unit which allows mobilization of the patient, with scientific digital flow recordings and an in built alarm system. Methods We evaluated the utility, staff and patient feedback of this device in a pilot evaluation in a regional thoracic unit in a structured format over a period of two months. Staff responses were graded on a scale of 1 to 6 [1 Excellent to 6 Poor]. Results 120 patients who underwent elective bullectomy/pleurectomy, VATS lung biopsies, VATS metastectomy and lung resections were evaluated. The staff feedback forms were positive. The staff liked the system as it was more scientific and accurately recordable. It made nursing and physiotherapy easier as they could mobilise patients early. The patients liked the compact design, weightlessness and the silence. It enabled mobilisation of the patients and scientific removal of chest drain. Conclusions Thopaz digital suction units were found to be user friendly and were liked by the staff and patients. The staff feedback stated the devices to be objective and scientific in making decisions about removal and enabled mobilisation.

  20. Microsatellite marker analysis of peach-potato aphids (Myzus persicae, Homoptera: Aphididae) from Scottish suction traps.

    Science.gov (United States)

    Malloch, G; Highet, F; Kasprowicz, L; Pickup, J; Neilson, R; Fenton, B

    2006-12-01

    The peach-potato aphid Myzus persicae (Sulzer) is an important vector of plant viruses. A network of suction traps collects aerial samples of this aphid in order to monitor and help predict its spatial distribution and likely impact on virus transmission in crops. A suction trap catch is thought to be a good representation of the total aphid pool. Sensitive molecular markers have been developed that determine the genetic composition of the M. persicae population. In Scotland, UK, these were applied to field collections revealing a limited number of clones. Molecular markers are less successful when applied to specimens that have been preserved in an ethanol-based trap fluid designed to preserve morphology. An assessment of different DNA extraction and PCR techniques is presented and the most efficient are used to analyse M. persicae specimens caught in the Dundee suction trap in 2001, a year when exceptionally high numbers were caught. The results reveal that the majority of the M. persicae caught belonged to two highly insecticide resistant clones. In addition, it was possible to compare the relative frequencies of genotypes caught in the trap with those collected at insecticide treated and untreated field sites in the vicinity. These results indicate that, in addition to suction trap data, the ability to sample field sites provides valuable early warning data which have implications for pest control and virus management strategies.

  1. Temperature measurement in WTE boilers using suction pyrometers.

    Science.gov (United States)

    Rinaldi, Fabio; Najafi, Behzad

    2013-11-15

    The temperature of the flue-gas in the post combustion zone of a waste to energy (WTE) plant has to be maintained within a fairly narrow range of values, the minimum of which is prescribed by the European Waste Directive 2000/76/CE, whereas the maximum value must be such as to ensure the preservation of the materials and the energy efficiency of the plant. A high degree of accuracy in measuring and controlling the aforementioned temperature is therefore required. In almost the totality of WTE plants this measurement process is carried out by using practical industrial thermometers, such as bare thermocouples and infrared radiation (IR) pyrometers, even if affected by different physical contributions which can make the gas temperature measurements incorrect. The objective of this paper is to analyze errors and uncertainties that can arise when using a bare thermocouple or an IR pyrometer in a WTE plant and to provide a method for the in situ calibration of these industrial sensors through the use of suction pyrometers. The paper describes principle of operation, design, and uncertainty contributions of suction pyrometers, it also provides the best estimation of the flue-gas temperature in the post combustion zone of a WTE plant and the estimation of its expanded uncertainty.

  2. Temperature Measurement in WTE Boilers Using Suction Pyrometers

    Directory of Open Access Journals (Sweden)

    Fabio Rinaldi

    2013-11-01

    Full Text Available The temperature of the flue-gas in the post combustion zone of a waste to energy (WTE plant has to be maintained within a fairly narrow range of values, the minimum of which is prescribed by the European Waste Directive 2000/76/CE, whereas the maximum value must be such as to ensure the preservation of the materials and the energy efficiency of the plant. A high degree of accuracy in measuring and controlling the aforementioned temperature is therefore required. In almost the totality of WTE plants this measurement process is carried out by using practical industrial thermometers, such as bare thermocouples and infrared radiation (IR pyrometers, even if affected by different physical contributions which can make the gas temperature measurements incorrect. The objective of this paper is to analyze errors and uncertainties that can arise when using a bare thermocouple or an IR pyrometer in a WTE plant and to provide a method for the in situ calibration of these industrial sensors through the use of suction pyrometers. The paper describes principle of operation, design, and uncertainty contributions of suction pyrometers, it also provides the best estimation of the flue-gas temperature in the post combustion zone of a WTE plant and the estimation of its expanded uncertainty.

  3. Blood loss associated with Ring uncemented total knee replacement: comparison between continuous and intermittent suction drainage.

    Science.gov (United States)

    Wittmann, F W; Ring, P A

    1984-01-01

    In a retrospective comparison of blood loss following uncemented total knee replacement, in which either continuous or intermittent suction drainage was used, measured blood loss was significantly greater with continuous drainage. However, a method of calculating actual blood loss demonstrated no significant difference. With intermittent drainage, more blood remains undetected around the knee joint; this technique should therefore be abandoned in favour of continuous suction drainage. PMID:6747978

  4. Hydrogenation study of suction-cast Ti{sub 40}Zr{sub 40}Ni{sub 20} quasicrystal

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Huogen; Li, Rong; Yin, Chen; Zheng, Shaotao; Zhang, Pengcheng [National Key Laboratory for Surface Physics and Chemistry, P.O. Box 718-35, Mian Yang 621907, Sichuan (China)

    2008-09-15

    Suction casting was predicted to be an usable method for improving the hydriding kinetics of Ti/Zr-based icosahedral quasicrystals (IQCs) in our previous work. To further determine it, a suction-cast Ti{sub 40}Zr{sub 40}Ni{sub 20} IQC alloy was used for hydrogenation studies by Pressure Composition Isotherm (PCI) and Temperature Programmed Desorption (TPD) techniques. The results showed that, this alloy absorbed hydrogen rapidly with obvious hydrogen pressure plateau and some reversibility, however, displayed very limited hydrogen capacity (about 0.7 wt.%) and low equilibrium pressure. After several hydrogenation/dehydrogenation cycles, the IQC structure transformed into two hydride phases, ZrH{sub 2-x} and one unknown, both of which decomposed at above 600 C, suggesting high thermo-stability for them. On the whole, indeed the suction-casting method can increase the hydrogen absorption rate of Ti/Zr-based IQCs, however, the hydrogenation properties of the Ti{sub 40}Zr{sub 40}Ni{sub 20} IQC alloy still need a mighty advancement. (author)

  5. Caisson disease of bone: a study of the Göttingen mini-pig as an animal model.

    Science.gov (United States)

    Gregg, P J; Walder, D N; Rannie, I

    1980-02-01

    Investigation of the exact aetiology, early diagnosis and prevention of caisson disease of bone has been hindered by the inability to produce, by the use of realistic compression/decompression exposures, truly comparable lesions in animals. Four Gottingen mini-pigs were subjected to repeated exposures to pressures of 27 p.s.i.g. for 6 h over a period of 9 months and decompressed according to standard tables. Two mini-pigs acted as controls. In one animal radiological changes were recognised in the left lower femoral shaft 19 weeks after the exposures were started and subsequent examination of that bone confirmed the presence, at that site, of a lesion which macroscopically and microscopically resembled, in every way, the appearances of those seen in the shafts of long bones in man. It is concluded therefore that, properly used, the mini-pig may be a suitable animal model for the study of this condition in man.

  6. Defining a Ventilation Strategy for Flexible Bronchoscopy on Mechanically Ventilated Patients in the Medical Intensive Care Unit.

    Science.gov (United States)

    Greenstein, Yonatan Y; Shakespeare, Eric; Doelken, Peter; Mayo, Paul H

    2017-07-01

    Flexible bronchoscopy (FB) in intubated patients on mechanical ventilation increases airway resistance. During FB, two ventilatory strategies are possible: maintaining tidal volume (VT) while maintaining baseline CO2 or allowing reduction of VT. The former strategy carries risk of hyperinflation due to expiratory flow limitation with FB. The aim of the authors was too study end expiratory lung volume (EELV) during FB of intubated subjects while limiting VT. We studied 16 subjects who were intubated on mechanical ventilation and required FB. Changes in EELV were measured by respiratory inductance plethysmography. Ventilator mechanics, EELV, and arterial blood gases, were measured. FB insertions decreased EELV in 64% of cases (-325±371 mL) and increased it in 32% of cases (65±59 mL). Suctioning decreased EELV in 76% of cases (-120±104 mL) and increased it in 16% of cases (29±33 mL). Respiratory mechanics were unchanged. Pre-FB and post-FB, PaO2 decreased by 61±96 mm Hg and PaCO2 increased by 15±7 mm Hg. There was no clinically significant increase in EELV in any subject during FB. Decreases in EELV coincided with FB-suctioning maneuvers. Peak pressure limiting ventilation protected the subject against hyperinflation with a consequent, well-tolerated reduction in VT, and hypercapnea. Suctioning should be limited, especially in patients vulnerable to derecruitment effect.

  7. Silent cooling system with a double suction type centrifugal fan with backward blades; Ryosuikomi turbo fan wo mochiita teisoon engine reikyaku system no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Funabashi, S. [Hitachi, Ltd., Tokyo (Japan); Nakamura, K. [Hitachi Construction Machinery Co. Ltd., Tokyo (Japan)

    2000-04-25

    We have developed a new cooling system for the engine of construction machinery. This system produces two different air flow routes by a double suction type centrifugal fan with backward blades. We first measured aerodynamic performance and sound level of the double suction type fan, which consists of two single suction type fans of different design, and compared these measurements to those of single suction type fans. Next, we installed the fan in a scale model of the new cooling system. The performance of this double suction type fan was different to that of a single suction type. It is considered that the effect of interaction of the exit flows from the two different fans caused this performance change. The test model installed in an engine compartment showed that this cooling system reduced the area of air inlets and outlets around the engine and did not cause re-circulation of cooling air. (author)

  8. Heat-transfer and pressure distributions for laminar separated flows downstream of rearward-facing steps with and without mass suction

    Science.gov (United States)

    Brown, R. D.; Jakubowski, A. K.

    1974-01-01

    Heat-transfer and pressure distributions were measured for laminar separated flows downstream of rearward-facing steps with and without mass suction. The flow conditions were such that the boundary-layer thickness was comparable to or larger than the step height. For both suction and no-suction cases, an increase in the step height resulted in a sharp decrease in the initial heat-transfer rates behind the step. Downstream, however, the heat transfer gradually recovered back to less than or near attached-flow values. Mass suction from the step base area increased the local heat-transfer rates; however, this effect was relatively weak for the laminar flows considered. Even removal of the entire approaching boundary layer raised the post-step heat-transfer rates only about 10 percent above the flatplate values. Post-step pressure distributions were found to depend on the entrainment conditions at separation. In the case of the solid-faced step, a sharp pressure drop behind the step was followed by a very short plateau and relatively fast recompression. For the slotted-step connected to a large plenum but without suction, the pressure drop at the base was much smaller and the downstream recompression more gradual than that for solid-faced step.

  9. Active technique by suction to control the flow structure over a van model

    Science.gov (United States)

    Harinaldi, Budiarso, Warjito, Kosasih, Engkos A.; Tarakka, Rustan; Simanungkalit, Sabar P.

    2012-06-01

    Today research trend in car aerodynamics are carried out from the point of view of the durable development. Some car companies have the objective to develop control solution that enable to reduce the aerodynamic drag of vehicle. It provides the possibility to modify the flow separation to reduce the development of the swirling structures around the vehicle. In this study, a family van is modeled with a modified form of Ahmed's body by changing the orientation of the flow from its original form (modified/reversed Ahmed Body). This model is equipped with a suction on the rear side to comprehensively examine the pressure field modifications that occur. The investigation combines computational and experimental work. The computational simulation used is k-epsilon flow turbulence model. The reversed Ahmed body used in the investigation has slant angle (φ) 35° at the front part. In the computational work, meshing type is tetra/hybrid element with hex core type and the grid number is more than 1.7 million in order to ensure detail discretization and more accurate calculation results. The boundary condition is upstream velocity of 11.1 m/s. Mean free stream at far upstream region is assumed in a steady state condition and uniform. The suction velocity is set at 1 m/s. Meanwhile in the experimental work a reversed Ahmed model is tested in a controlled wind tunnel experiments. The main measurement is the drag aerodynamic measurement at rear of the body of the model using strain gage. The results show that the application of a suction in the rear part of the van model give the effect of reducing the wake and the vortex is formed. Aerodynamic drag reduction close to 24% for the computational approach and 14.8% for the experimental approach by introducing a suction have been obtained.

  10. Vortical and acoustical mode coupling inside a porous tube with uniform wall suction.

    Science.gov (United States)

    Jankowskia, T A; Majdalani, J

    2005-06-01

    This paper considers the oscillatory motion of gases inside a long porous tube of the closed-open type. In particular, the focus is placed on describing an analytical solution for the internal acoustico-vortical coupling that arises in the presence of appreciable wall suction. This unsteady field is driven by longitudinal oscillatory waves that are triggered by small unavoidable fluctuations in the wall suction speed. Under the assumption of small amplitude oscillations, the time-dependent governing equations are linearized through a regular perturbation of the dependent variables. Further application of the Helmholtz vector decomposition theorem enables us to discriminate between acoustical and vortical equations. After solving the wave equation for the acoustical contribution, the boundary-driven vortical field is considered. The method of matched-asymptotic expansions is then used to obtain a closed-form solution for the unsteady momentum equation developing from flow decomposition. An exact series expansion is also derived and shown to coincide with the numerical solution for the problem. The numerically verified end results suggest that the asymptotic scheme is capable of providing a sufficiently accurate solution. This is due to the error associated with the matched-asymptotic expansion being smaller than the error introduced in the Navier-Stokes linearization. A basis for comparison is established by examining the evolution of the oscillatory field in both space and time. The corresponding boundary-layer behavior is also characterized over a range of oscillation frequencies and wall suction velocities. In general, the current solution is found to exhibit features that are consistent with the laminar theory of periodic flows. By comparison to the Sexl profile in nonporous tubes, the critically damped solution obtained here exhibits a slightly smaller overshoot and depth of penetration. These features may be attributed to the suction effect that tends to

  11. Fundaciones para turbinas eólicas costa afuera Foundations for offshore wind turbines

    Directory of Open Access Journals (Sweden)

    Felipe Alberto Villalobos Jara

    2009-01-01

    Full Text Available Este artículo describe el comienzo y la evolución de la hoy en día creciente mundialmente industria de la energía eólica costa afuera. Como un caso particular, se describe la actual política de energías renovables en el Reino Unido. Se explican las características de las cargas ambientales existentes costa afuera, tipos de suelos del fondo marino y las fundaciones que se utilizan comúnmente. El tipo de estructura y régimen de carga establecen nuevas condiciones desde el punto de vista de la Ingeniería Civil. Se presentan las cámaras a succión como una fundación alternativa para turbinas de viento costa afuera. Las cámaras a succión son actualmente una alternativa aceptada en vez de usar pilotes en aplicaciones para la industria del petróleo y el gas. Sin embargo, este no es el caso todavía en aplicaciones para aerogeneradores costa afuera.This paper describes the beginning and evolution of the now worldwide growing offshore wind energy industry. In particular, the current renewable energy policy in the UK is described. The characteristics of the environmental loads offshore, type of seabed soils and foundations commonly adopted are explained. The type of structure and loading regime establish new conditions from a Civil Engineering point of view. Suction caissons are introduced as an alternative foundation for offshore wind turbines. Suction caissons are currently an accepted alternative to pile foundations in applications for the oil and gas industry. However, this is not yet the case in applications for offshore wind turbines.

  12. Suction blister lesions and epithelialization monitored by optical coherence tomography

    DEFF Research Database (Denmark)

    Ahlström, M G; Gjerdrum, L M R; Larsen, H F

    2018-01-01

    suction blister was raised on each buttock, and the blister roof was excised. Lesions were covered with moisture-retaining dressing. In Study 1, the lesions were OCT-scanned on day 0 (D0), D2 and D4 and excised for histological examination. In Study 2, the progress of epithelialization and skin barrier...

  13. Experimental Investigation of the Motion and Shape of Flexible Objects near a Pump Inlet

    DEFF Research Database (Denmark)

    Jensen, Anna Lyhne; Abou Ackl, Raja; Gerlach, Stefan

    Previous investigations of clogging effects in waste water pumps have focused on the impact of pumping contaminated water on the pump performance, as well as the influence of the operating point on the location of clogged material in the pump and in the pumping system. The present work aims...... to characterise the dynamics of flexible material entering a rotating impeller. Experiments are carried out in a wet pit located in the Department of Fluid System Dynamics in TU Berlin. The wet pit is modified with an acrylic plate placed at the bottom of the pit, enabling visual access to the suction side...

  14. Closed suction drainage using Lichtenstein technique in preventing wound complications following inguinal hernioplasty: brief report

    Directory of Open Access Journals (Sweden)

    Hamid Reza Hemmati

    2015-03-01

    Results: No adverse event including hematoma, seroma or wound infection occurred in either group with or without closed suction drainage in the first 10 days after surgery. Only one patient carried wound infection during days 10 to 15 following operation who was in the group with closed drainage (P=1.00. Conclusion: In this study, Seroma and hematoma was not observed in patients with and without closed suction drainage. To avoid drains' complications, indiscriminate use of antibiotics, prolonged hospital stay, we do not recommend the use of drains in this type of surgery.

  15. Systematic review and meta-analysis of closed suction drainage versus non-drainage in primary hip arthroplasty.

    LENUS (Irish Health Repository)

    Kelly, Enda G

    2014-03-01

    The routine use of drains in surgery has been dogmatically instituted in some disciplines. Orthopaedic surgery is one such sub-speciality. The use of postoperative closed suction drainage in total hip arthroplasty (THA) has become increasingly controversial with multiple randomised control trials performed to assess the benefit to outcome in THA. The hypothesis of this systematic review is that closed suction drainage does not infer a benefit and increase transfusion requirements of primary total hip arthroplasty patients. A systematic review and meta-analysis was conducted adhering to the PRISMA guidelines. A search of the available literature was performed on PubMed, Cochrane Central Registry of Controlled Trials, MEDLINE (OVID) and EMBASE using a combination of MeSH terms and Boolean operators. All data analysis was performed using the Cochrane Collaboration\\'s Review Manager 5.1. Sixteen studies (n=2705) were included in the analysis. Post-operative closed suction drainage was found to increase total blood loss and blood transfusion requirements (p<0.05). Surgical site infection demonstrated no significant difference between the two groups (p=0.82). No significant difference in haematoma formation between groups (p=0.19) was elicited. The routine use of closed suction drainage systems post primary hip arthroplasty is not supported by this meta-analysis. However, the heterogeneity between studies does limit the accuracy of the meta-analysis.

  16. Conditions and phase shift of fluid resonance in narrow gaps of bottom mounted caissons

    Science.gov (United States)

    Zhu, Da-tong; Wang, Xing-gang; Liu, Qing-jun

    2017-12-01

    This paper studies the viscid and inviscid fluid resonance in gaps of bottom mounted caissons on the basis of the plane wave hypothesis and full wave model. The theoretical analysis and the numerical results demonstrate that the condition for the appearance of fluid resonance in narrow gaps is kh=(2 n+1)π ( n=0, 1, 2, 3, …), rather than kh= nπ ( n=0, 1, 2, 3, …); the transmission peaks in viscid fluid are related to the resonance peaks in the gaps. k and h stand for the wave number and the gap length. The combination of the plane wave hypothesis or the full wave model with the local viscosity model can accurately determine the heights and the locations of the resonance peaks. The upper bound for the appearance of fluid resonance in gaps is 2 b/ Lreason for the phase shift of the resonance peaks is the inductive factors. The number of resonance peaks in the spectrum curve is dependent on the ratio of the gap length to the grating constant. The heights and the positions of the resonance peaks predicted by the present models agree well with the experimental data.

  17. Assessment of Stability and Energy Dissipation Performances of an Antifer Layer Protected Caisson

    Directory of Open Access Journals (Sweden)

    M. Sedat Kabdaşlı

    2015-08-01

    Full Text Available The present study intends to assess the stability and energy dissipation performances of a breakwater configuration (APC protected by an antifer layer. For comparison, an ordinary caisson (OC, which was 5% wider and 10% heavier, was also investigated. Physical models were implemented and tested under regular and irregular waves; and resulting linear and angular displacements were directly measured via a photogrammetric method. Additionally, wave forces and resulting horizontal displacements were estimated both from recorded pressure data and from individual incident waves by modified Goda method. To calculate the horizontal displacement, the estimated wave force time series were directly double-integrated, whilst the theoretical method proposed by Shimosako et al. (1994 were used on the individual force values. Although OC was tested under shorter durations and had a more favorable superstructure in terms of resisting forces, the results indicated that APC was significantly more stable. Energy dissipation performance of the tested configurations were quantified in terms of spectral averaged and phase resolved reflection coefficients, whereas antifer damage ratio was measured on a block-count basis. Results indicated that the APC configuration had an enhanced performance of dissipating the wave energy; moreover, the dissipated energy directly links to antifer damage ratio.

  18. [Pain assessment of tracheal suctioning on brain injury patients by pain behavioral indicator scale (ESCID)].

    Science.gov (United States)

    López-López, C; Murillo-Pérez, M A; Morales-Sánchez, C; Torrente-Vela, S; Orejana-Martín, M; García-Iglesias, M; Cuenca-Solanas, M; Alted-López, E

    2014-01-01

    To assess pain response on patients with moderate to severe head injury before a common nursing procedure: tracheal suctioning. An observational longitudinal pilot study with consecutive sampling performed from September to December of 2012. Pain was assessed by a pain behavioral indicator scale 5 minutes before, meanwhile and 15 minutes after tracheal suctioning the days 1, 3 and 6 of their intensive care unit (ICU) stay, as well as a non-painful procedure: rubbing with gauze the forearm of the patient. Pseudo-analgesia and hemodynamic variables were also recorded. Descriptive analysis of the variables, inferential statistics with t-student and Anova with SPSS 17.0; statistical tests were considered significant if the critical level observed was less than 5% (P.05) were shown. Data for the painless procedure were significantly different on day 6 (P<.05) CONCLUSION: During tracheal suctioning in patients with head injury in the first 6 days in the ICU, objective mild-moderate pain according to ESCID scale has been detected. Copyright © 2013 Elsevier España, S.L.U. y SEEIUC. All rights reserved.

  19. The radontechnical process of the sub-slab suction system in detached, semi-detached and terraced houses; Imupistejaerjestelmaen radontekninen toiminta eri tyyppisissae pien- ja rivitaloissa

    Energy Technology Data Exchange (ETDEWEB)

    Kettunen, A.V.; Rissanen, R.; Viljanen, M. [Helsinki Univ. of Technology, Otaniemi (Finland). Lab. of Structural Engineering and Building Physics; Arvela, H. [Finnish Centre for Radiation and Nuclear Safety, Helsinki (Finland)

    1997-12-31

    The sub-slab suction system is a repair method for decreasing radon transfer from soil to indoor air in houses. The sub-slab suction system changes the flow field with the aim to reduce the radon content under the ground slab or/and changes the flow direction from indoor air to foundation soil. The study is divided into the theoretical and experimental part. The theoretical part concentrates on solving the factors affecting the sub-slab suction system taking into consideration features of old houses. The experimental part uses the results of the theoretical part when the level and the type of the suction point had been chosen. The effect of the sub-slab suction system was tested with pressure difference experiments and the radon content measurements in 26 different, typical Finnish detached, semi-detached and terrace houses.

  20. Suction/inspiration against resistance or standardized Mueller maneuver: a new breathing technique to improve contrast density within the pulmonary artery: a pilot CT study

    Energy Technology Data Exchange (ETDEWEB)

    Gutzeit, Andreas [Paracelsus Medical University Salzburg, Department of Radiology, Salzburg (Austria); Hirslanden Hospital St. Anna, Institute of Radiology and Nuclear Medicine, Clinical Research Unit, Lucerne (Switzerland); Kantonsspital Winterthur, Department of Radiology, Winterthur (Switzerland); Froehlich, Johannes M.; Weymarn, Constantin von; Goyen, Matthias [Hirslanden Hospital St. Anna, Institute of Radiology and Nuclear Medicine, Clinical Research Unit, Lucerne (Switzerland); Waelti, Stephan [Cantonal Hospital St. Gallen, Department of Radiology and Nuclear Medicine, St. Gallen (Switzerland); Roos, Justus E. [Duke University Medical Center, Department of Radiology, Durham, NC (United States); Meissnitzer, Matthias; Hergan, Klaus [Paracelsus Medical University Salzburg, Department of Radiology, Salzburg (Austria); Czell, David [Cantonal Hospital Winterthur, Department of Neurology, Winterthur (Switzerland); Reischauer, Carolin [Paracelsus Medical University Salzburg, Department of Radiology, Salzburg (Austria); Hirslanden Hospital St. Anna, Institute of Radiology and Nuclear Medicine, Clinical Research Unit, Lucerne (Switzerland)

    2015-11-15

    Our aim was to prospectively investigate whether the recently introduced suction/inspiration against resistance breathing method leads to higher computed tomography (CT) contrast density in the pulmonary artery compared to standard breathing. The present study was approved by the Medical Ethics committee and all subjects gave written informed consent. Fifteen patients, each without suspicious lung emboli, were randomly assigned to four different groups with different breathing maneuvers (suction against resistance, Valsalva, inspiration, expiration) during routine CT. Contrast enhancement in the central and peripheral sections of the pulmonary artery were measured and compared with one another. Peripheral enhancement during suction yielded increased mean densities of 138.14 Hounsfield units (HU) (p = 0.001), compared to Valsalva and a mean density of 67.97 HU superior to inspiration (p = 0.075). Finally, suction in comparison to expiration resulted in a mean increase of 30.51 HU (p = 0.42). Central parts of pulmonary arteries presented significantly increased enhancement values (95.74 HU) for suction versus the Valsalva technique (p = 0.020), while all other mean densities were in favour of suction (versus inspiration: p = 0.201; versus expiration: p = 0.790) without reaching significance. Suction/Inspiration against resistance is a promising technique to improve contrast density within pulmonary vessels, especially in the peripheral parts, in comparison to other breathing maneuvers. (orig.)

  1. Air suctioning during colon biopsy forceps removal reduces bacterial air contamination in the endoscopy suite.

    Science.gov (United States)

    Vavricka, S R; Tutuian, R; Imhof, A; Wildi, S; Gubler, C; Fruehauf, H; Ruef, C; Schoepfer, A M; Fried, M

    2010-09-01

    Bacterial contamination of endoscopy suites is of concern; however studies evaluating bacterial aerosols are lacking. We aimed to determine the effectiveness of air suctioning during removal of biopsy forceps in reducing bacterial air contamination. This was a prospective single-blinded trial involving 50 patients who were undergoing elective nontherapeutic colonoscopy. During colonoscopy, endoscopists removed the biopsy forceps first without and then with suctioning following contact with the sigmoid mucosa. A total of 50 L of air was collected continuously for 30 seconds at 30-cm distance from the biopsy channel valve of the colonoscope, with time starting at forceps removal. Airborne bacteria were collected by an impactor air sampler (MAS-100). Standard Petri dishes with CNA blood agar were used to culture Gram-positive bacteria. Main outcome measure was the bacterial load in endoscopy room air. At the beginning and end of the daily colonoscopy program, the median (and interquartile [IQR] range) bioaerosol burden was 4 colony forming units (CFU)/m (3) (IQR 3 - 6) and 16 CFU/m (3) (IQR 13 - 18), respectively. Air suctioning during removal of the biopsy forceps reduced the bioaerosol burden from a median of 14 CFU/m (3) (IQR 11 - 29) to a median of 7 CFU/m (3) (IQR 4 - 16) ( P = 0.0001). Predominantly enterococci were identified on the agar plates. The bacterial aerosol burden during handling of biopsy forceps can be reduced by applying air suction while removing the forceps. This simple method may reduce transmission of infectious agents during gastrointestinal endoscopies. Copyright Georg Thieme Verlag KG Stuttgart . New York.

  2. Laboratory determined suction potential of Topopah Spring tuff at high temperatures

    International Nuclear Information System (INIS)

    Daily, W.; Lin, Wunan.

    1991-01-01

    The purpose of this work is to experimentally determine the capillary suction potential of Topopah Spring tuff from Yucca Mountain, Nye County, Nevada. This data can be used to help characterize the unsaturated hydraulic properties of the densely welded tuff at this site. 7 refs., 4 figs., 1 tab

  3. Instruction Workbook for Tracheostomy Suctioning and Misting in a School Setting.

    Science.gov (United States)

    Wolf, Karen McKinney; Roach, Antionette Andolfatto

    The handbook presents California guidelines for training school personnel to provide skilled nursing procedures such as tracheostomy suctioning and misting for students with special health needs. The workbook begins with an overview of the anatomy and function of the respiratory system, specifically breathing mechanics. Part 2 considers the…

  4. A wet-tolerant adhesive patch inspired by protuberances in suction cups of octopi

    Science.gov (United States)

    Baik, Sangyul; Kim, Da Wan; Park, Youngjin; Lee, Tae-Jin; Ho Bhang, Suk; Pang, Changhyun

    2017-06-01

    Adhesion strategies that rely on mechanical interlocking or molecular attractions between surfaces can suffer when coming into contact with liquids. Thus far, artificial wet and dry adhesives have included hierarchical mushroom-shaped or porous structures that allow suction or capillarity, supramolecular structures comprising nanoparticles, and chemistry-based attractants that use various protein polyelectrolytes. However, it is challenging to develop adhesives that are simple to make and also perform well—and repeatedly—under both wet and dry conditions, while avoiding non-chemical contamination on the adhered surfaces. Here we present an artificial, biologically inspired, reversible wet/dry adhesion system that is based on the dome-like protuberances found in the suction cups of octopi. To mimic the architecture of these protuberances, we use a simple, solution-based, air-trap technique that involves fabricating a patterned structure as a polymeric master, and using it to produce a reversed architecture, without any sophisticated chemical syntheses or surface modifications. The micrometre-scale domes in our artificial adhesive enhance the suction stress. This octopus-inspired system exhibits strong, reversible, highly repeatable adhesion to silicon wafers, glass, and rough skin surfaces under various conditions (dry, moist, under water and under oil). To demonstrate a potential application, we also used our adhesive to transport a large silicon wafer in air and under water without any resulting surface contamination.

  5. Abdominal drainage following cholecystectomy: high, low, or no suction?

    OpenAIRE

    McCormack, T. T.; Abel, P. D.; Collins, C. D.

    1983-01-01

    A prospective trial to assess the effect of suction in an abdominal drain following cholecystectomy was carried out. Three types of closed drainage system were compared: a simple tube drain, a low negative pressure drain, and a high negative pressure drain: 120 consecutive patients undergoing cholecystectomy were randomly allocated to one of the three drainage groups. There was no significant difference in postoperative pyrexia, wound infection, chest infection, or hospital stay. This study f...

  6. Fabricating Zr-Based Bulk Metallic Glass Microcomponent by Suction Casting Using Silicon Micromold

    Directory of Open Access Journals (Sweden)

    Zhijing Zhu

    2014-08-01

    Full Text Available A suction casting process for fabricating Zr55Cu30Al10Ni5 bulk metallic glass microcomponent using silicon micromold has been studied. A complicated BMG microgear with 50 μm in module has been cast successfully. Observed by scanning electron microscopy and laser scanning confocal microscopy, we find that the cast microgear duplicates the silicon micromold including the microstructure on the surface. The amorphous state of the microgear is confirmed by transmission election microscopy. The nanoindentation hardness and elasticity modulus of the microgear reach 6.5 GPa and 94.5 GPa. The simulation and experimental results prove that the suction casting process with the silicon micromold is a promising one-step method to fabricate bulk metallic glass microcomponents with high performance for applications in microelectromechanical system.

  7. Magnetohydrodynamics effect on three-dimensional viscous incompressible flow between two horizontal parallel porous plates and heat transfer with periodic injection/suction

    Directory of Open Access Journals (Sweden)

    R. C. Chaudhary

    2004-11-01

    Full Text Available We investigate the hydromagnetic effect on viscous incompressible flow between two horizontal parallel porous flat plates with transverse sinusoidal injection of the fluid at the stationary plate and its corresponding removal by periodic suction through the plate in uniform motion. The flow becomes three dimensional due to this injection/suction velocity. Approximate solutions are obtained for the flow field, the pressure, the skin-friction, the temperature field, and the rate of heat transfer. The dependence of solution on M (Hartmann number and λ (injection/suction is investigated by the graphs and tables.

  8. Suction removal of sediment from between armour blocks. Part 2. Waves

    DEFF Research Database (Denmark)

    Dixen, Figen Hatipoglu; Sumer, B. Mutlu; Fredsøe, Jørgen

    2008-01-01

    When a stone/armor layer on a sand bed is exposed to flow, the sand underneath will be agitated by the flow turbulence. When the flow velocity reaches a critical value, the sand will be sucked (winnowed out) from between the armor blocks. In a previous investigation, we studied suction removal of...

  9. The impact of soil suction variation on earthquake intensity indices

    Directory of Open Access Journals (Sweden)

    Biglari Mahnoosh

    2016-01-01

    Full Text Available Soil properties can completely change the ground motion characteristics as they travel from the bedrock to the surface because, soil as a low-pass filter, may amplify or deamplify seismic motions in some frequencies on the wave travelling path. Recent studies about the advanced unsaturated soil mechanics clearly shows that dynamic properties of soils, including small-strain shear modulus (Gmax, shear modulus reduction (G/Gmax, and damping ratio (D curves are affected by changes in the soil suction level. The current study present nonlinear time-dependent analysis of three different unsaturated soils available in the literature with different ranges of nonlinear behaviour that earlier have been studied on unsaturated dynamic models. Since, the earthquake intensity parameters can be used to describe the damage potential of an earthquake, the focus of this paper is to evaluate the impact of the suction variation on the engineering ground motion parameters, including peak values of strong motion, Vmax/Amax, root-mean-square acceleration, Arias intensity, characteristic intensity, cumulative absolute velocity, acceleration spectrum intensity, effective design acceleration, A95 parameter and predominant period separately under the near-field and the far-field seismicity categories.

  10. Numerical analyses of caisson breakwaters on soft foundations under wave cyclic loading

    Science.gov (United States)

    Wang, Yuan-zhan; Yan, Zhen; Wang, Yu-chi

    2016-03-01

    A caisson breakwater is built on soft foundations after replacing the upper soft layer with sand. This paper presents a dynamic finite element method to investigate the strength degradation and associated pore pressure development of the intercalated soft layer under wave cyclic loading. By combining the undrained shear strength with the empirical formula of overconsolidation clay produced by unloading and the development model of pore pressure, the dynamic degradation law that describes the undrained shear strength as a function of cycle number and stress level is derived. Based on the proposed dynamic degradation law and M-C yield criterion, a dynamic finite element method is numerically implemented to predict changes in undrained shear strength of the intercalated soft layer by using the general-purpose FEM software ABAQUS, and the accuracy of the method is verified. The effects of cycle number and amplitude of the wave force on the degradation of the undrained shear strength of the intercalated soft layer and the associated excess pore pressure response are investigated by analyzing an overall distribution and three typical sections underneath the breakwater. By comparing the undrained shear strength distributions obtained by the static method and the quasi-static method with the undrained shear strength distributions obtained by the dynamic finite element method in the three typical sections, the superiority of the dynamic finite element method in predicting changes in undrained shear strength is demonstrated.

  11. INCOMPRESSIBLE LAMINAR BOUNDARY LAYER CONTROL BY BLOWING AND SUCTION

    OpenAIRE

    AZZEDINE NAHOUI; LAKHDAR BAHI

    2013-01-01

    A two-dimensional incompressible laminar boundary layer and its control using blowing and suction over a flat plate and around the NACA 0012 and 661012 profiles, is studied numerically. The study is based on the Prandtl boundary layer model using the finite differences method and the Crank-Nicolson scheme. The velocity distribution, the boundary layer thickness and the friction coefficient, are determined and presented with and without control. The application of the control technique, has de...

  12. A Constitutive Model for Unsaturated soils based on a Compressibility Framework dependent on Suction and Degree of Saturation

    OpenAIRE

    Sitarenios Panagiotis; Kavvadas Michael

    2016-01-01

    The Modified Cam Clay model is extended to account for the behaviour of unsaturated soils using Bishop’s stress. To describe the Loading – Collapse behaviour, the model incorporates a compressibility framework with suction and degree of saturation dependent compression lines. For simplicity, the present paper describes the model in the triaxial stress space with characteristic simulations of constant suction compression and triaxial tests, as well as wetting tests. The model reproduces an evo...

  13. Investigation on creep behavior of geo-materials with suction control technique

    Directory of Open Access Journals (Sweden)

    Nishimura Tomoyoshi

    2016-01-01

    Full Text Available The compacted bentonite which has typical couple problem associated to thermal - hydration - mechanical – chemical (THMC consist of one component of engineered barrier. Recently, the couple THMC formulation modelling suggested by some researchers can be predicted basically phenomena for engineered barrier that approach to correct evaluate satisfied facilities. The compacted bentonite is essentially unsaturated condition, some behaviors for bentonite has similar or close with generally expansive unsaturated soils. Therefore, hydrations have given significant influence on deformation of compacted bentonite such as swelling. There are many researches for swelling behavior of compacted bentonite within soaking. Extended theoretical or experimental investigations for unsaturated soil mechanics are possible to describe the strength-deformation behavior of compacted bentonite with suction controlling principle. A new method of determining the failure phase such as great axis deformation and destructions like strip of surface in the laboratory is described and the creep behavior of compacted bentonite is considered under maintain of high relative humidity environment. The creep deformation measured using improved cyclic relative humidity control apparatus in terms of specific suction control technique.

  14. Comparison of numerical formulations for the modeling of tensile loaded suction buckets

    DEFF Research Database (Denmark)

    Sørensen, Emil Smed; Clausen, Johan Christian; Damkilde, Lars

    2017-01-01

    The tensile resistance of a suction bucket is investigated using three different numerical formulations. The first formulation utilizes the three-field u-p-U formulation accounting for solid and fluid displacements, u and U, as well as the pore-fluid pressure, p. The two other formulations compri...

  15. Kinematics of suction feeding in the seahorse Hippocampus reidi.

    Science.gov (United States)

    Roos, Gert; Van Wassenbergh, Sam; Herrel, Anthony; Aerts, Peter

    2009-11-01

    Fish typically use a rostro-caudal wave of head expansion to generate suction, which is assumed to cause a uni-directional, anterior-to-posterior flow of water in the expanding head. However, compared with typical fish, syngnathid fishes have a remarkably different morphology (elongated snout, small hyoid, immobile pectoral girdle) and feeding strategy (pivot feeding: bringing the small mouth rapidly close to the prey by neurocranial dorsorotation). As a result, it is unclear how suction is generated in Syngnathidae. In this study, lateral and ventral expansions of the head were quantified in Hippocampus reidi and linked to the kinematics of the mouth, hyoid and neurocranium. In addition, the flow velocities inside the bucco-pharyngeal cavity and in front of the mouth were calculated. Our data suggest that the volume changes caused by lateral expansion are dominant over ventral expansion. Maximum gape, neurocranium rotation and hyoid depression are all reached before actual volume increase and before visible prey movement. This implies that, unlike previously studied teleosts, hyoid rotation does not contribute to ventral expansion by lowering the floor of the mouth during prey capture in H. reidi. The lateral volume changes show a rostro-caudal expansion, but the maximal flow velocity is not near the mouth aperture (as has been demonstrated for example in catfish) but at the narrow region of the buccal cavity, dorsal to the hyoid.

  16. Successful Laparoscopically Assisted Transcervical Suction Evacuation of Interstitial Pregnancy following Failed Methotrexate Injection in a Community Hospital Setting

    Directory of Open Access Journals (Sweden)

    Rani B. Fritz

    2014-01-01

    Full Text Available We report on a case of a patient with an early diagnosed cornual ectopic pregnancy following failed methotrexate treatment. The patient was subsequently taken to the operating room for a laparoscopic guided transcervical suction curettage of the cornual ectopic. The surgery was successful and the patient was followed up until her urine pregnancy test was negative. We conclude that in properly selected patients, cornual ectopic pregnancy may be treated with transcervical suction curettage.

  17. Differential Effects of Endotracheal Suctioning on Gas Exchanges in Patients with Acute Respiratory Failure under Pressure-Controlled and Volume-Controlled Ventilation

    Directory of Open Access Journals (Sweden)

    Xiao-Wei Liu

    2015-01-01

    Full Text Available This study was conducted to evaluate the effects of open endotracheal suctioning on gas exchange and respiratory mechanics in ARF patients under the modes of PCV or VCV. Ninety-six ARF patients were treated with open endotracheal suctioning and their variations in respiratory mechanics and gas exchange after the suctions were compared. Under PCV mode, compared with the initial level of tidal volume (VT, ARF patients showed 30.0% and 27.8% decrease at 1 min and 10 min, respectively. Furthermore, the initial respiratory system compliance (Crs decreased by 29.6% and 28.5% at 1 min and 10 min, respectively. Under VCV mode, compared with the initial level, 38.6% and 37.5% increase in peak airway pressure (PAP were found at 1 min and 10 min, respectively. Under PCV mode, the initial PaO2 increased by 6.4% and 10.2 % at 3 min and 10 min, respectively, while 18.9% and 30.6% increase of the initial PaO2 were observed under VCV mode. Summarily, endotracheal suctioning may impair gas exchange and decrease lung compliance in ARF patients receiving mechanical ventilation under both PCV and VCV modes, but endotracheal suctioning effects on gas exchange were more severe and longer-lasting under PCV mode than VCV.

  18. Aerosol distribution during open suctioning and long-term surveillance of air quality in a respiratory care center within a medical center.

    Science.gov (United States)

    Chung, Fen-Fang; Lin, Hui-Ling; Liu, Hsueh-Erh; Lien, Angela Shin-Yu; Hsiao, Hsiu-Feng; Chou, Lan-Ti; Wan, Gwo-Hwa

    2015-01-01

    The investigation of hospital air quality has been conducted in wards, ICUs, operating theaters, and public areas. Few studies have assessed air quality in respiratory care centers (RCCs), especially in mechanically ventilated patients with open suctioning. The RCC air quality indices (temperature, relative humidity, levels of CO2, total volatile organic compounds, particulate matter [PM], bacteria, and fungi) were monitored over 1 y. The air around the patient's head was sampled during open suctioning to examine the probability of bioaerosol exposure affecting health-care workers. This investigation found that the levels of indoor air pollutants (CO2, PM, bacteria, and fungi) were below the indoor air quality standard set by the Taiwan Environmental Protection Agency. Meanwhile, the levels of total volatile organic compounds sometimes exceeded the indoor air quality standard, particularly in August. The identified bacterial genera included Micrococcus species, Corynebacterium species, and Staphylococcus species, and the predominant fungal genera included yeast, Aspergillus species, Scopulariopsis species, and Trichoderma species. Additionally, airborne PM2.5, PM1, and bacteria were clearly raised during open suctioning in mechanically ventilated patients. This phenomenon demonstrated that open suctioning may increase the bacterial exposure risk of health-care workers. RCC air quality deserves long-term monitoring and evaluation. Health-care workers must implement self-protection strategies during open suctioning to ensure their occupational health and safety in health-care settings. Copyright © 2015 by Daedalus Enterprises.

  19. Development in corrosion resistance by microstructural refinement in Zr-16 SS 304 alloy using suction casting technique

    Energy Technology Data Exchange (ETDEWEB)

    Das, N., E-mail: nirupamd@barc.gov.in; Sengupta, P.; Abraham, G.; Arya, A.; Kain, V.; Dey, G.K.

    2016-08-15

    Highlights: • Grain refinement was made in Zr–16 wt.% SS alloy while prepared by suction casting process. • Distribution of Laves phase, e.g., Zr{sub 2}(Fe, Cr) was raised in suction cast (SC) Zr–16 wt.% SS. • Corrosion resistance was improved in SC alloy compared to that of arc-melt-cast alloy. • Grain refinement in SC alloy assisted for an increase in its corrosion resistance. - Abstract: Zirconium (Zr)-stainless steel (SS) hybrid alloys are being considered as baseline alloys for developing metallic-waste-form (MWF) with the motivation of disposing of Zr and SS base nuclear metallic wastes. Zr–16 wt.% SS, a MWF alloy optimized from previous studies, exhibit significant grain refinement and changes in phase assemblages (soft phase: Zr{sub 2}(Fe, Cr)/α-Zr vs. hard phase: Zr{sub 3}(Fe, Ni)) when prepared by suction casting (SC) technique in comparison to arc-cast-melt (AMC) route. Variation in Cr-distribution among different phases are found to be low in suction cast alloy, which along with grain refinement restricted Cr-depletion at the Zr{sub 2}(Fe, Cr)/Zr interfaces, prone to localized attack. Hence, SC alloy, compared to AMC alloy, showed lower current density, higher potential at the breakdown of passivity and higher corrosion potential during polarization experiments (carried out under possible geological repository environments, viz., pH 8, 5 and 1) indicating its superior corrosion resistance.

  20. On the influence of buoyancy and suction/injection In Heat and Mass ...

    African Journals Online (AJOL)

    In this paper, we examined the influence of buoyancy and suction/injection in the problem of unsteady convection with chemical reaction and radiative heat transfer past a flat porous plate moving through a binary mixture in an optically thin environment is presented. The dimensionless governing equations for this ...

  1. Review of pump suction reducer selection: Eccentric or concentric reducers

    OpenAIRE

    Mahaffey, R M; van Vuuren, S J

    2014-01-01

    Eccentric reducers are traditionally recommended for the pump suction reducer fitting to allow for transportation of air through the fitting to the pump. The ability of a concentric reducer to provide an improved approach flow to the pump while still allowing air to be transported through the fitting is investigated. Computational fluid dynamics (CFD) were utilised to analyse six concentric and six eccentric reducer geometries at four different inlet velocities to determine the flow velocity ...

  2. Boundary layer on a flat plate with suction; Couche limite sur paroi plane poreuse avec aspiration

    Energy Technology Data Exchange (ETDEWEB)

    Favre, A; Dumas, R; Verollet, E [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires; Institut de Mecanique Statistique de la Turbulence, Faculte des Sciences de Marseille, 13 (France)

    1961-07-01

    This research done in wind tunnel concerns the turbulent boundary layer of a porous flat plate with suction. The porous wall is 1 m long and begins 1 m downstream of the leading edge. The Reynolds number based on the boundary layer thickness is of the order of 16.300. The suction rate defined as the ratio of the velocity perpendicular to the wall to the external flow velocity ranges from 0 to 2 per cent. The pressure gradient can be controlled. The mean velocity profiles have been determined for various positions and suction rates by means of total pressure probes together with the intensities of the turbulent velocity fluctuations components, energy spectra and correlations by means of hot wire anemometers, spectral analyser and correlator. The stream lines, the values of the viscous and turbulent shear stresses, of the local wall friction, of the turbulent energy production term, with some information on the dissipation of the energy have been derived from these measurements. For these data the integral of equation of continuity in boundary layer have been drawn. The suction effects on the boundary layer are important. The suction thoroughly alters the mean velocity profiles by increasing the viscous shear stresses near the wall and decreasing them far from the wall, it diminishes the longitudinal and transversal turbulence intensities, the turbulent shear stresses, and the production of energy of turbulence. These effects are much stressed in the inner part of the boundary layer. On the other hand the energy spectra show that the turbulence scale is little modified, the boundary layer thickness being not much diminished by the suction. The suction effects can be appreciated by comparing twice the suction rate to the wall friction coefficient (assumed airtight), quite noticeable as soon as the rate is about unity, they become very important when it reaches ten. (author) [French] Ces recherches, effectuees en soufflerie, concernent la couche limite turbulente d

  3. STUDY ON THE REASONABLE EVALUATION OF SOIL PROPERTIES APPLIED IN THE DESIGN OF SHINSO FOUNDATION (JAPANESE STYLE CAISSON TYPE PILE) ON THE SLOPE

    Science.gov (United States)

    Yasuzato, Toshinori; Samizo, Junichi; Maeda, Yoshito; Abe, Tetsuo; Matsuki, Satoshi; Okutani, Junpei

    The objective of this study is to find ways to maximize the design economy of the shinso foundation (Japanese style caisson type pile) on the rock slope through an evaluation of strength properties of the rock before and after plasticity. We investigate the influence of soil properties on the design result by carrying out experiments which give the soil properties before and after plasticity and by doing parametric studies on the soil properties. Experiment using small-scale shinso foundation is performed to verify the validity of result of examinations. Comparison between the experiment and the analytical result reveals the bearing capacity characteristics of the shinso foundation on the slope and gives new insights on the more economical design of the shinso foundation.

  4. Saline instillation before tracheal suctioning decreases the incidence of ventilator-associated pneumonia.

    Science.gov (United States)

    Caruso, Pedro; Denari, Silvia; Ruiz, Soraia A L; Demarzo, Sergio E; Deheinzelin, Daniel

    2009-01-01

    To compare the incidence of ventilator-associated pneumonia (VAP) with or without isotonic saline instillation before tracheal suctioning. As a secondary objective, we compared the incidence of endotracheal tube occlusion and atelectasis. Randomized clinical trial. The study was conducted in a medical surgical intensive care unit of an oncologic hospital. We selected consecutive patients needing mechanical ventilation for >72 hrs. Patients were allocated into two groups: a saline group that received instillation of 8 mL of saline before tracheal suctioning and a control group which did not. VAP was diagnosed based on clinical suspicion and confirmed by bronchoalveolar lavage quantitative culture. The incidence of atelectasis on daily chest radiography and endotracheal tube occlusions were recorded. The sample size was calculated to a power of 80% and a type I error probability of 5%. One hundred thirty patients were assigned to the saline group and 132 to the control group. The baseline demographic variables were similar between groups. The rate of clinically suspected VAP was similar in both groups. The incidence of microbiological proven VAP was significantly lower in the saline group (23.5% x 10.8%; p = 0.008) (incidence density/1.000 days of ventilation 21.22 x 9.62; p < 0.01). Using the Kaplan-Meier curve analysis, the proportion of patients remaining without VAP was higher in the saline group (p = 0.02, log-rank test). The relative risk reduction of VAP in the saline instillation group was 54% (95% confidence interval, 18%-74%) and the number needed to treat was eight (95% confidence interval, 5-27). The incidence of atelectases and endotracheal tube occlusion were similar between groups. Instillation of isotonic saline before tracheal suctioning decreases the incidence of microbiological proven VAP.

  5. Boundary layer development on turbine airfoil suction surfaces

    Science.gov (United States)

    Sharma, O. P.; Wells, R. A.; Schlinker, R. H.; Bailey, D. A.

    1981-01-01

    The results of a study supported by NASA under the Energy Efficient Engine Program, conducted to investigate the development of boundary layers under the influence of velocity distributions that simulate the suction sides of two state-of-the-art turbine airfoils, are presented. One velocity distribution represented a forward loaded airfoil ('squared-off' design), while the other represented an aft loaded airfoil ('aft loaded' design). These velocity distributions were simulated in a low-speed, high-aspect-ratio wind tunnel specifically designed for boundary layer investigations. It is intended that the detailed data presented in this paper be used to develop improved turbulence model suitable for application to turbine airfoil design.

  6. Measuring lip force by oral screens Part 2: The importance of screen design, instruction and suction.

    Science.gov (United States)

    Wertsén, Madeleine; Stenberg, Manne

    2017-10-01

    The aim of this study was to find a reliable method for measuring lip force and to find the most important factors that influence the measurements in terms of magnitude and variability. The hypothesis tested was that suction is involved and thus the instruction and the design of the oral screen are of importance when measuring lip force. This is a methodological study in a healthy population. This study was conducted in a general community. The designs of the screens were soft and hard prefabricated screens and 2 semi-individually made with a tube allowing air to pass. The screens and the instructions squeeze or suck were tested on 29 healthy adults, one at a time and on 4 occasions. The test order of the screens was randomized. Data were collected during 4 consecutive days, and the procedure was repeated after 1 month. The participants were 29 healthy adult volunteers. The instruction was an important mean to distinguish between squeezing and sucking. The design of the screen affected the lip force so that it increases in relation to the projected area of the screen. A screen design with a tube allowing air to pass made it possible to avoid suction when squeezing. By measuring with and without allowing air to pass, it was possible to distinguish between suction related and not suction related lip force. The additional screen pressure when sucking was related to the ability to produce a negative intraoral pressure. In conclusion lip force increases in relation to the projected area of the screen, sucking generally increases the measured lip force and the additional screen pressure when sucking is related to the ability to produce a negative intraoral pressure.

  7. MHD Boundary Layer Flow of Dilatant Fluid in a Divergent Channel with Suction or Blowing

    International Nuclear Information System (INIS)

    Bhattacharyya, Krishnendu; Layek, G. C.

    2011-01-01

    An analysis is carried out to study a steady magnetohydrodynamic (MHD) boundary layer flow of an electrically conducting incompressible power-law non-Newtonian fluid through a divergent channel. The channel walls are porous and subjected to either suction or blowing of equal magnitude of the same kind of fluid on both walls. The fluid is permeated by a magnetic field produced by electric current along the line of intersection of the channel walls. The governing partial differential equation is transformed into a self-similar nonlinear ordinary differential equation using similarity transformations. The possibility of boundary layer flow in a divergent channel is analyzed with the power-law fluid model. The analysis reveals that the boundary layer flow (without separation) is possible for the case of the dilatant fluid model subjected to suitable suction velocity applied through its porous walls, even in the absence of a magnetic field. Further, it is found that the boundary layer flow is possible even in the presence of blowing for a suitable value of the magnetic parameter. It is found that the velocity increases with increasing values of the power-law index for the case of dilatant fluid. The effects of suction/blowing and magnetic field on the velocity are shown graphically and discussed physically. (fundamental areas of phenomenology(including applications))

  8. Reduction of the suction pressure of a liquid ring vacuum pump with a supersonic gas ejector

    Directory of Open Access Journals (Sweden)

    Olšiak Róbert

    2018-01-01

    Full Text Available A supersonic gas ejector in conjunction with a liquid ring vacuum pump is used for creating and maintaining vacuum in a chamber for technological purposes. In this paper the authors submit an overview about the problematics of suction pressure reduction with a supersonic gas ejector used as a pre-stage of a liquid ring vacuum pump. This system has also the function of a cavitation protection due to the higher pressure present at the suction throat of the vacuum pump. A part of this paper is devoted to the governing equations used at the definition of the flow through an ejector. The experimental studies are then carried out in or own laboratory for verification purposes.

  9. 玉砂利を使用したオープンケーソンに作用する周面摩擦に関する研究(II)

    OpenAIRE

    五味, 信治; 岡本, 将昭; 風間, 秀彦

    2002-01-01

    The Space System caisson (SS caisson) foundation is the open caisson method. This method reduces frictional force of caisson wall surface using the gravel. In this paper, frictional force of caisson wall surface was measured in the field. Construction case of open caisson method and SS caisson foundation is compared. And, the case as the shape of the SS caisson foundation differs from the construction region is shown. From the case of the measurement, the effectiveness of frictional force red...

  10. Effect of inflow discharges on the development of matric suction and volumetric water content for dike during overtopping tests

    Science.gov (United States)

    Hassan, Marwan A.; Ismail, Mohd A. M.

    2017-10-01

    The point of this review is to depict the impact of various inflow discharge rate releases on the instruments of matric suction and volumetric water content during an experimental test of spatial overtopping failure at school of civil engineering in universiti Sains of Malaysia. A dry sand dike was conducted inside small flume channel with twelve sensors of tensiometer and Time-Domain Reflectometer (TDR). Instruments are installed in the soil at different locations in downstream and upstream slopes of the dike for measuring the response of matric suction and volumetric water content, respectively. Two values of inflow discharge rates of 30 and 40 L/min are utilized as a part of these experiments to simulate the effectiveness of water reservoirs in erosion mechanism. The outcomes demonstrate that the matric suction and volumetric water content are decreased and increased, respectively for both inflow discharges. The higher inflow discharges accelerate the saturation of dike soil and the erosion process faster than that for the lower inflow discharges.

  11. Treatment of herniated lumbar disc by percutaneous laser disc decompression combined with synchronous suction technique through syringe

    Institute of Scientific and Technical Information of China (English)

    Dhir B. Gurung; Gaojian Tao; Hongyi Lin; Yanning Qian; Jian Lin

    2007-01-01

    Objective: To compare the outcomes of percutaneous laser disc decompression (PLDD) and PLDD with synchronous suction through syringe in the patients with herniated lumbar disc (HLD). Methods: Forty-two patients with HLD on MRI and those who did not respond to conservative treatment for 6 weeks were randomly divided into group A and group B. In group A, the patients were treated with PLDD and those in group B with PLDD and synchronous suction through syringe. GaAIAS diode laser at 810 nm was used for the ablation in both groups. The treatment effect was evaluated by modified MacNab's criteria on the 7th, 30th and 90th day. Results: Evaluated by modified MacNab's criteria, the percentages of the excellent and good cases in total patients treated for group B and A were 80.95% and 57.14% on the 7th follow-up day, 85.71% and 66.67% on the 30th follow-up day, and 95.24% and 71.43% on the 90th follow-up day, respectively. Conclusion: Synchronous suction technique through syringe during PLDD improves the overall outcome in the treatment of herniated lumbar disc.

  12. Analysis Of Primary Coolant Suction Side Pressure In The Delay Chamber Of The RSG-GAS

    International Nuclear Information System (INIS)

    Dibyo, Sukmanto

    2000-01-01

    Delay chamber is a tank to delay flow that located in the primary cooling suction side of RSG-GAS. A void occurred when operation reactor caused by too high the delta P at inlet suction pump. The condition may be avoided by using one line mode of the cooling flow. The analysis show that void volume in the delay chamber is occurred because the coolant negative pressure lowers the saturation pressure should be avoided though decreasing the delta P until about 0.1 bar at about 45 exp 0 C. Solution suggested are to use bypass flow from the spent fuel to the delay chamber. Coolant temperature can be also decreased by decreasing the power level of the reactor as well as improving the heat exchanger and cooling tower performances

  13. Bacteremia during adenoidectomy: a comparison of suction diathermy adenoid ablation and adenoid curettage.

    LENUS (Irish Health Repository)

    Casserly, Paula

    2010-08-01

    Transient bacteremia is induced by adenoidectomy when the integrity of the nasopharyngeal membrane is broken. The aim of this study was to determine the incidence of bacteremia in patients undergoing adenoidectomy, to identify the causative organisms, and to compare the incidences of bacteremia between the two techniques suction diathermy and curettage.

  14. Suppression of secondary flows in a double suction centrifugal pump with different loading distributions

    International Nuclear Information System (INIS)

    Leng, H F; Wang, F J; Zhang, Z C; Yao, Z F; Zhou, P J

    2013-01-01

    Secondary flow is one of the main reasons for low efficiency in double suction centrifugal pump. In a 3-D inverse design method, the pump blade could be designed by a specified loading distribution to control the flow field in pump. In order to study the influence of loading distribution on secondary flow of a double suction centrifugal pump, the external characteristics and the internal flow field of the pump with three kinds of loading distributions are analysed by using CFD approach. According to the simulation results, it is found that the form of fore-loading distribution at shroud and aft-loading distribution at hub could improve the optimal efficiency and broaden the high efficiency area of the pump. Furthermore, the secondary flow in impeller exit region and volute could be significantly suppressed if the slope of loading distribution curve of shroud is set to be −0.7

  15. Cyclosporin A levels in suction-blister fluid of patients with psoriasis treated systemically

    NARCIS (Netherlands)

    Meinardi, M. M.; van Eendenburg, J. P.; Oosting, J.; van Boxtel, C. J.; de Rie, M. A.; Bos, J. D.

    1990-01-01

    Oral cyclosporin A (CyA) is highly effective in the treatment of psoriasis. The long-term use is limited by dose-dependent side-effects, and the local concentration of CyA is a determining factor in treatment. The concentration of CyA in suction-blister fluid (SBF) and in whole blood was assessed

  16. In situ sampling of small volumes of soil solution using modified micro-suction cups

    NARCIS (Netherlands)

    Shen, Jianbo; Hoffland, E.

    2007-01-01

    Two modified designs of micro-pore-water samplers were tested for their capacity to collect unbiased soil solution samples containing zinc and citrate. The samplers had either ceramic or polyethersulfone (PES) suction cups. Laboratory tests of the micro-samplers were conducted using (a) standard

  17. A comparison of the disconnection technique with continuous bronchial suction for lung deflation when using the Arndt endobronchial blocker during video-assisted thoracoscopy: A randomised trial.

    Science.gov (United States)

    El-Tahan, Mohamed R

    2015-06-01

    The use of the Arndt endobronchial blocker has not gained widespread acceptance during video-assisted thoracoscopic surgery (VATS) because of its high cost and longer time to operative lung collapse especially in patients with chronic obstructive pulmonary disease (COPD). The use of a ventilator disconnection technique has been shown to produce a comparable degree of lung collapse when used with either a double-lumen tube or an Arndt endobronchial blocker. We hypothesised that the use of bronchial suction through the suction port of the endobronchial blocker would be associated with a comparable time to achieve optimum lung collapse as the disconnection technique. A randomised, double-blind study. Single university hospital. Fifty-eight patients with spontaneous pneumothorax scheduled for elective VATS using the Arndt endobronchial blocker for one-lung ventilation (OLV). Patients were randomly assigned to one of two groups (n = 29 per group) to deflate the operative lung with either disconnection of the endotracheal tube from the ventilator for 60 s prior to inflation of the endobronchial blocker or connection of a suction pressure of -30 cmH2O to the suction port of the endobronchial blocker through the barrel of a 1 ml syringe. The primary outcome was the time to total lung collapse. Secondary outcomes included surgeon rating of lung collapse, overall surgeon satisfaction, need for further fibreoptic bronchial suction manoeuvres and intraoperative hypoxaemia. The bronchial suction technique was associated with a significantly shorter time to total lung collapse than the disconnection method [93 (95% confidence interval, 95% CI 81.3 to 103.7) vs. 197 (95% CI 157.4 to 237) s respectively; P < 0.001]. Both the disconnection and bronchial suction groups had a comparable surgical rating of excellent lung collapse 40 min after the start of OLV (65.5 vs. 79.3%, respectively; P = 0.24), overall surgeon satisfaction [median (interquartile range, IQR) 9 (8 to 10) vs. 9 (8

  18. A retrospective study of the use of active suction wound drains in dogs and cats.

    Science.gov (United States)

    Bristow, P C; Halfacree, Z J; Baines, S J

    2015-05-01

    To report indications for use and complications associated with commonly used closed active suction wound drains in a large number of clinical cases. Retrospective review of medical case records (from 2004 to 2010) for dogs and cats that had a closed active suction drain placed into a wound. Only the four most common drain types were included: Mini Redovac®, Redovac®, Jackson Pratt® and Wound Evac®. Two hundred and fifty-three drains were placed in 33 cats and 195 dogs. Mini Redovac drains were used most frequently in cats (76 · 5%) and Redovac drains in dogs (54 · 3%). The infection rate for clean surgeries in dogs was 15 · 6% (unattainable in cats). Major complications occurred in four dogs; minor complications occurred in 12 drains in cats (35 · 3%), and in 74 drains in dogs (33 · 8%). There was no statistically significant association between the type of drain and complication rate for either species. Although closed active suction drains can be used with low risk of major complications, they lead to a high rate of infection in clean surgeries in dogs. It is recommended that such drains are kept in place for the shortest time possible and that strict asepsis is adhered to both during placement and management. © 2015 British Small Animal Veterinary Association.

  19. 玉砂利を使用したオープンケーソンに作用する周面摩擦に関する研究(III)

    OpenAIRE

    岡本, 将昭; 五味, 信治; ミント, ウィ; 平賀, 理; 上西, 恭子; 風間, 秀彦

    2003-01-01

    Caissons or laterally loaded piers are widely used in marine constructions where loads are heavy, to support traffic poles and bridges to resist large lateral loads, and to support transmission line towers to resist large uplifting forces. The space system caisson (SS caisson) method, which is the operation method of constructing caisson foundation, is classified into open caisson construction method. In SS caisson method, space gravel is filled between caisson wall surface and soil. A detail...

  20. Determination of Matric Suction and Saturation Degree for Unsaturated Soils, Comparative Study - Numerical Method versus Analytical Method

    Science.gov (United States)

    Chiorean, Vasile-Florin

    2017-10-01

    Matric suction is a soil parameter which influences the behaviour of unsaturated soils in both terms of shear strength and permeability. It is a necessary aspect to know the variation of matric suction in unsaturated soil zone for solving geotechnical issues like unsaturated soil slopes stability or bearing capacity for unsaturated foundation ground. Mathematical expression of the dependency between soil moisture content and it’s matric suction (soil water characteristic curve) has a powerful character of nonlinearity. This paper presents two methods to determine the variation of matric suction along the depth included between groundwater level and soil level. First method is an analytical approach to emphasize one direction steady state unsaturated infiltration phenomenon that occurs between the groundwater level and the soil level. There were simulated three different situations in terms of border conditions: precipitations (inflow conditions on ground surface), evaporation (outflow conditions on ground surface), and perfect equilibrium (no flow on ground surface). Numerical method is finite element method used for steady state, two-dimensional, unsaturated infiltration calculus. Regarding boundary conditions there were simulated identical situations as in analytical approach. For both methods, was adopted the equation proposed by van Genuchten-Mualen (1980) for mathematical expression of soil water characteristic curve. Also for the unsaturated soil permeability prediction model was adopted the equation proposed by van Genuchten-Mualen. The fitting parameters of these models were adopted according to RETC 6.02 software in function of soil type. The analyses were performed in both methods for three major soil types: clay, silt and sand. For each soil type were concluded analyses for three situations in terms of border conditions applied on soil surface: inflow, outflow, and no flow. The obtained results are presented in order to highlight the differences

  1. Set-up and Test Procedure for Suction Installation and Uninstallation of Bucket Foundation

    DEFF Research Database (Denmark)

    Koteras, Aleksandra Katarzyna

    This technical report describes the set-up and the test procedures for installation and uninstallation of medium-scale model of bucket foundation that can be performed in the geotechnical part of laboratory in Aalborg University. The installation of bucket foundation can be tested with the use of......) and loading frame used for those tests have been already used for axially static and cyclic loading of piles (Thomassen, 2015a) and for axially static and cyclic loading of bucket foundation (Vaitkunaite et al., 2015).......This technical report describes the set-up and the test procedures for installation and uninstallation of medium-scale model of bucket foundation that can be performed in the geotechnical part of laboratory in Aalborg University. The installation of bucket foundation can be tested with the use...... of suction under the bucket lid or by applying additional force through the hydraulic piston, forcing the bucket to penetrate into the soil. Tests for uninstallation are performed also with the use of water pressure, as a reverse process to the suction installation. Both installation and uninstallation tests...

  2. 75 FR 70112 - Medical Devices; General and Plastic Surgery Devices; Classification of Non-Powered Suction...

    Science.gov (United States)

    2010-11-17

    .... FDA-2010-N-0513] Medical Devices; General and Plastic Surgery Devices; Classification of Non-Powered... risks. Adverse tissue reaction Material degradation Improper function of suction apparatus (e.g., reflux.... Material degradation Section 8. Stability and Shelf Life. [[Page 70113

  3. 無載荷オープンケーソンと周辺砂利層の摩擦抵抗に関する研究(II)

    OpenAIRE

    風間, 秀彦; 岩下, 和義; 岩間, 正人; 五味, 信治; 中出, 睦

    2007-01-01

     The SS caisson (SPACE SYSTEM CAISSON) method fills the space (gap) between caisson circumference surface and rock with the space gravel and it is the open caisson method which gently installs the caisson only by the dead weight at the good accuracy by reducing skin friction resistance which depends on caisson circumference surface, while the stability of country rock is attempted. The result of numerical value using DEM and model experiment of SS caisson model with exhaust slot was mainly co...

  4. 無載荷オープンケーソンと周辺砂利層との摩擦抵抗に関する研究

    OpenAIRE

    風間, 秀彦; 岩下, 和義; 岩間, 正人; 五味, 信治; 中出, 睦

    2006-01-01

    Space System caisson (SS caisson), which is the operation method of constructing caisson foundation, is one of open caisson foundations. The skin friction is reduced by filling space between caisson wall and soil with boulder. Therefore, SS caisson can be sinking by own weight. The skin friction of SS caisson is smaller, but it cannot be quantitatively estimated.So, model tests were carried out to know the tendency of skin friction. In this time, DEM (Distinct Element Method) analysis was per...

  5. 玉砂利を使用したオープンケーソンに作用する周面摩擦に関する研究(V)

    OpenAIRE

    中出, 睦; 五味, 信治; 岩間, 正人; 平賀, 理; 風間, 秀彦

    2005-01-01

    The SS caisson (SPACE SYSTEM CAISSON) method fills the space (gap) between caisson circumference surface and country rock with the space gravel, and it is the open caisson method which gently installs the caisson only by the dead weight at the good accuracy by reducing skin friction resistance which depends on caisson circumference surface, while the stability of country rock is attempted. The following have been carried out: Until now indoor model experiment of the SS caisson model with exha...

  6. 無載荷オープンケーソンと周辺砂利層の摩擦抵抗に関する研究(III)

    OpenAIRE

    風間, 秀彦; 竹内, 康成; 五味, 信治; 中出, 睦

    2008-01-01

     The SS caisson (SPACE SYSTEM CAISSON) method fills the space (gap) between caisson circumference surface and rock with the space gravel and it is the open caisson method which gently installs the caisson only by the dead weight at the good accuracy by reducing skin friction resistance which depends on caisson circumference surface, while the stability of country rock is attempted. From current study of SS caisson, it found that skin friction is almost unaffected at compared with three factor...

  7. Efficacy of intermittent sub-glottic suctioning in prevention of ventilator-associated pneumonia- A preliminary study of 100 patients

    Directory of Open Access Journals (Sweden)

    M N Vijai

    2016-01-01

    Full Text Available Background and Aims: Oropharyngeal colonisation followed by aspiration of contaminated secretions is the major cause for ventilator-associated pneumonia (VAP. Pooled secretions present in the sub-glottic area above inflated endotracheal tube cuff may be aspirated into the lower airways. It was hypothesised that intermittent suctioning of sub-glottic secretions would prevent VAP. Methods: Group I (n = 50 patients were intubated with HiLo Evac™ endotracheal (ET tube with facility for sub-glottic suctioning, and Group II (n = 50 patients were intubated with HiLo Contour™ ET tube without such facility. In the Group I, sub-glottic suctioning was performed every 2 h. Incidence of VAP, mean ventilator days, Intensive Care Unit (ICU stay and mortality were compared. Qualitative variables were reported as percentages and were compared by Chi-square test or unpaired two-tailed, Fisher′s exact test, as appropriate, to analyse the significance of difference between the two groups. Results: The two groups were similar with respect to demographic characteristics. VAP was seen in 6% of patients in Group I and 22% of patients in Group II (P = 0.021. Both early- and late-onset VAPs were significantly reduced in Group I. Both ventilator days (8.0 vs. 6.45; P = 0.001 and ICU stay (8.33 vs. 6.33; P = 0.001 on the day of onset of VAP were significantly more in the Group I. Total ventilator days were significantly less (6.52 vs. 8.32; P = 0.006 with lower incidence of mortality (36% vs. 48%; P = 0.224 in the Group I. Conclusion: Intermittent sub-glottic suctioning reduces the incidence of VAP including late-onset VAP.

  8. Efficacy of intermittent sub-glottic suctioning in prevention of ventilator-associated pneumonia- A preliminary study of 100 patients.

    Science.gov (United States)

    Vijai, M N; Ravi, Parli R; Setlur, Rangaraj; Vardhan, Harsh

    2016-05-01

    Oropharyngeal colonisation followed by aspiration of contaminated secretions is the major cause for ventilator-associated pneumonia (VAP). Pooled secretions present in the sub-glottic area above inflated endotracheal tube cuff may be aspirated into the lower airways. It was hypothesised that intermittent suctioning of sub-glottic secretions would prevent VAP. Group I (n = 50) patients were intubated with HiLo Evac™ endotracheal (ET) tube with facility for sub-glottic suctioning, and Group II (n = 50) patients were intubated with HiLo Contour™ ET tube without such facility. In the Group I, sub-glottic suctioning was performed every 2 h. Incidence of VAP, mean ventilator days, Intensive Care Unit (ICU) stay and mortality were compared. Qualitative variables were reported as percentages and were compared by Chi-square test or unpaired two-tailed, Fisher's exact test, as appropriate, to analyse the significance of difference between the two groups. The two groups were similar with respect to demographic characteristics. VAP was seen in 6% of patients in Group I and 22% of patients in Group II (P = 0.021). Both early- and late-onset VAPs were significantly reduced in Group I. Both ventilator days (8.0 vs. 6.45; P = 0.001) and ICU stay (8.33 vs. 6.33; P = 0.001) on the day of onset of VAP were significantly more in the Group I. Total ventilator days were significantly less (6.52 vs. 8.32; P = 0.006) with lower incidence of mortality (36% vs. 48%; P = 0.224) in the Group I. Intermittent sub-glottic suctioning reduces the incidence of VAP including late-onset VAP.

  9. Stability analysis on the flow and heat transfer of nanofluid past a stretching/shrinking cylinder with suction effect

    Science.gov (United States)

    Bakar, Nor Ashikin Abu; Bachok, Norfifah; Arifin, Norihan Md.; Pop, Ioan

    2018-06-01

    The steady boundary layer flow over a stretching/shrinking cylinder with suction effect is numerically studied. Using a similarity transformations, the governing partial differential equations are transformed into a set of nonlinear differential equations and have been solved numerically using a bvp4c code in Matlab software. The nanofluid model used is taking into account the effects of Brownian motion and thermophoresis. The influences of the governing parameters namely the curvature parameter γ, mass suction parameter S, Brownian motion parameter Nb and thermophoresis parameter Nt on the flow, heat and mass transfers characteristics are presented graphically. The numerical results obtained for the skin friction coefficient, local Nusselt number and local Sherwood number are thoroughly determined and presented graphically for several values of the governing parameters. From our investigation, it is found that the non-unique (dual) solutions exist for a certain range of mass suction parameter. It is observed that as curvature parameter increases, the skin friction coefficient and heat transfer rate decrease, meanwhile the mass transfer rates increase. Moreover, the stability analysis showed that the first solution is linearly stable, while the second solution is linearly unstable.

  10. Simulation of flow structure in the suction pipe of a hydroturbine by integral characteristics

    DEFF Research Database (Denmark)

    Kuibin, P.A.; Okulov, Valery; Pylev, I.M.

    2006-01-01

    Within the framework of a model of a twisted flow of an inviscid incompressible liquid, we solve the problem of determining the frequency and amplitude of oscillations caused by the precession of a helical vortex core in the suction tube of a hydroturbine from the specified integral characteristics...

  11. 77 FR 25717 - Proposed Issuance of a General NPDES Permit for Small Suction Dredging

    Science.gov (United States)

    2012-05-01

    ...) General Permit (IDG-37-0000) to placer mining operations in Idaho for small suction dredges (intake nozzle... ENVIRONMENTAL PROTECTION AGENCY [FRL-9666-1] Proposed Issuance of a General NPDES Permit for Small... certifies ``will not, if promulgated, have a significant economic impact on a substantial number of small...

  12. Controls on shallow landslide initiation: Diverse hydrologic pathways, 3D failure geometries, and unsaturated soil suctions

    Science.gov (United States)

    Reid, Mark; Iverson, Richard; Brien, Dianne; Iverson, Neal; LaHusen, Richard; Logan, Matthew

    2017-04-01

    Shallow landslides and ensuing debris flows are a common hazard worldwide, yet forecasting their initiation at a specific site is challenging. These challenges arise, in part, from diverse near-surface hydrologic pathways under different wetting conditions, 3D failure geometries, and the effects of suction in partially saturated soils. Simplistic hydrologic models typically used for regional hazard assessment disregard these complexities. As an alterative to field studies where the effects of these governing factors can be difficult to isolate, we used the USGS debris-flow flume to conduct controlled, field-scale landslide initiation experiments. Using overhead sprinklers or groundwater injectors on the flume bed, we triggered failures using three different wetting conditions: groundwater inflow from below, prolonged moderate-intensity precipitation, and bursts of high-intensity precipitation. Failures occurred in 6 m3 (0.65-m thick and 2-m wide) prisms of loamy sand on a 31° slope; these field-scale failures enabled realistic incorporation of nonlinear scale-dependent effects such as soil suction. During the experiments, we monitored soil deformation, variably saturated pore pressures, and moisture changes using ˜50 sensors sampling at 20 Hz. From ancillary laboratory tests, we determined shear strength, saturated hydraulic conductivities, and unsaturated moisture retention characteristics. The three different wetting conditions noted above led to different hydrologic pathways and influenced instrumental responses and failure timing. During groundwater injection, pore-water pressures increased from the bed of the flume upwards into the sediment, whereas prolonged moderate infiltration wet the sediment from the ground surface downward. In both cases, pore pressures acting on the impending failure surface slowly rose until abrupt failure. In contrast, a burst of intense sprinkling caused rapid failure without precursory development of widespread positive pore

  13. Short-snouted toothless ichthyosaur from China suggests Late Triassic diversification of suction feeding ichthyosaurs.

    Directory of Open Access Journals (Sweden)

    P Martin Sander

    Full Text Available BACKGROUND: Ichthyosaurs were an important group of Mesozoic marine reptiles and existed from the Early Triassic to the early Late Cretaceous. Despite a great diversity in body shapes and feeding adaptations, all share greatly enlarged eyes, an elongated rostrum with numerous conical teeth, and a streamlined body. METHODOLOGY/PRINCIPAL FINDINGS: Based on new material from China and the restudy of Shastasaurus pacificus, we here reinterpret the classical large-bodied Late Triassic ichthyosaur genus Shastasaurus to differ greatly from the standard ichthyosaurian body plan, indicating much greater morphological diversity and range of feeding adaptations in ichthyosaurs than previously recognized. Phylogenetic analysis indicates a monophyletic clade consisting of the giant Shonisaurus sikanniensis, Guanlingsaurus liangae, and Shastasaurus pacificus to which the genus name Shastasaurus is applied. Shastasaurus liangae comb. nov. is from the Late Triassic (Carnian Xiaowa Formation of Guizhou Province, southwestern China. The species combines a diminutive head with an entirely toothless and greatly reduced snout. The species also has by far the highest vertebral count among ichthyosaurs (86 presacral vertebrae and >110 caudal vertebrae, a count that is also very high for tetrapods in general. A reduced toothless snout and a diminutive head is also apparently present in the giant S. sikanniensis and presumably in S. pacificus. CONCLUSIONS/SIGNIFICANCE: In analogy to many modern odontocetes, Shastasaurus is interpreted as a specialized suction feeder on unshelled cephalopods and fish, suggesting a unique but widespread Late Triassic diversification of toothless, suction-feeding ichthyosaurs. Suction feeding has not been hypothesized for any of the other diverse marine reptiles of the Mesozoic before, but in Shastasaurus may be linked to the Late Triassic minimum in atmospheric oxygen.

  14. Active Flow Control in a Radial Vaned Diffuser for Surge Margin Improvement: A Multislot Suction Strategy

    Directory of Open Access Journals (Sweden)

    Aurélien Marsan

    2017-01-01

    Full Text Available This work is the final step of a research project that aims at evaluating the possibility of delaying the surge of a centrifugal compressor stage using a boundary-layer suction technique. It is based on Reynolds-Averaged Navier-Stokes numerical simulations. Boundary-layer suction is applied within the radial vaned diffuser. Previous work has shown the necessity to take into account the unsteady behavior of the flow when designing the active flow control technique. In this paper, a multislot strategy is designed according to the characteristics of the unsteady pressure field. Its implementation results in a significant increase of the stable operating range predicted by the unsteady RANS numerical model. A hub-corner separation still exists further downstream in the diffuser passage but does not compromise the stability of the compressor stage.

  15. Stall margin improvement of an axial flow fan with end wall injection and suction; Hekimen fukidashi suidashi ni yoru han'yo jikuryu sofuki no shissoku kaizen

    Energy Technology Data Exchange (ETDEWEB)

    Nishioka, K.; Kuroda, H.; Obata, S.; Chimura, O. [National Defense Academy, Kanagawa (Japan)

    1999-06-25

    The experimental studies are conducted to reveal the mechanism of stall margin improvement of an axial flow fan by injection or suction from the end wall. In case of injection, the largest improvement is obtained by the injection at about 0. 14 {approx} 0 .21 times axial chord length downstream from leading edge. The reason for large improvement is that stall vortex, shed intermittent separation vortex and tip leakage vortex are dissipated by this injection, and also that this blowing suppresses the separation of boundary layer. In case of suction, the largest improvement is found for the suction from the end wall near leading edge. The amplitude of periodic static pressure after stall inception becomes smaller in comparison with injection cases. These effects are increased with the increase of suction flow rate, because the discharge of the vortex occurs more easily. On the other hand, the suction from the upstream of leading edge reduces the axial velocity near rotor tip, and then it induces stall. Also we tried to visualize the tip region flow, The suppression mechanism is discussed based on the visualization. The suppression of stall is successfully photographed. (author)

  16. Comparative study of the characteristics of some suction devices for gas sampling applications; Etude comparative des caracteristiques de quelques dispositifs d'aspiration a l'usage des prelevements de gaz

    Energy Technology Data Exchange (ETDEWEB)

    Donguy, R.; Drouet, J.

    1959-06-15

    Gas sampling (used to determine the characteristics of dusts or aerosols contained in a gas) needs a suction device. In order to select the right device and the right conditions of use, the characteristics and performances of various suction devices (helicoidal and centrifugal aspirators, air pumps, volumetric pumps) have been experimentally measured: flow rate, head loss, sampling volume and duration, aerosol and dust concentration, gas density, nature of the gas, suction circuit configuration, etc.

  17. Free Convection from a Semi-Infinite Vertical Plate with Discontinuous Blowing or Suction.

    Science.gov (United States)

    1981-03-01

    SCHIESSR UNCLASSIFIED; EhEllllEllEE EE[E]hEEEIllIEllhlEEIl EEEEEIIIEEEEI EEEIIIIIIIIII EIIIEIIEEEEII EEEIIIIIIIIIIE LVEL NAVAL POSTGRADUATE SCHOOL Monterey...the unsteady free convective flow past a simi-infinite porous plate with constant suction were studied through mathematical analysis by Soundalgekar...boundary-layers and; therefore, will often indicate a preferred method of analytical solution. Although there are several possible mathematical techniques

  18. Effect of a syringe aspiration technique versus a mechanical suction technique and use of N-butylscopolammonium bromide on the quantity and quality of bronchoalveolar lavage fluid samples obtained from horses with the summer pasture endophenotype of equine asthma.

    Science.gov (United States)

    Bowser, Jacquelyn E; Costa, Lais R R; Rodil, Alba U; Lopp, Christine T; Johnson, Melanie E; Wills, Robert W; Swiderski, Cyprianna E

    2018-03-01

    OBJECTIVE To evaluate the effect of 2 bronchoalveolar lavage (BAL) sampling techniques and the use of N-butylscopolammonium bromide (NBB) on the quantity and quality of BAL fluid (BALF) samples obtained from horses with the summer pasture endophenotype of equine asthma. ANIMALS 8 horses with the summer pasture endophenotype of equine asthma. PROCEDURES BAL was performed bilaterally (right and left lung sites) with a flexible videoendoscope passed through the left or right nasal passage. During lavage of the first lung site, a BALF sample was collected by means of either gentle syringe aspiration or mechanical suction with a pressure-regulated wall-mounted suction pump. The endoscope was then maneuvered into the contralateral lung site, and lavage was performed with the alternate fluid retrieval technique. For each horse, BAL was performed bilaterally once with and once without premedication with NBB (21-day interval). The BALF samples retrieved were evaluated for volume, total cell count, differential cell count, RBC count, and total protein concentration. RESULTS Use of syringe aspiration significantly increased total BALF volume (mean volume increase, 40 mL [approx 7.5% yield]) and decreased total RBC count (mean decrease, 142 cells/μL), compared with use of mechanical suction. The BALF nucleated cell count and differential cell count did not differ between BAL procedures. Use of NBB had no effect on BALF retrieval. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that retrieval of BALF by syringe aspiration may increase yield and reduce barotrauma in horses at increased risk of bronchoconstriction and bronchiolar collapse. Further studies to determine the usefulness of NBB and other bronchodilators during BAL procedures in horses are warranted.

  19. Application of the time dependent suction to free convection laminar flow in the presence of transverse magnetic field

    International Nuclear Information System (INIS)

    Agrawal, H.L.; Ram, P.C.

    1980-01-01

    The laminar unsteady free convection and heat transfer of an electrically conducting fluid past a porous vertical flat plate in the presence of uniform transverse magnetic field is investigated when the free stream velocity and suction at the plate are oscillatory functions of time, viscous dissipation term and Joul's dissipation term have been neglected at low velocity. Expressions for velocity and temperature distributions have been obtained in the non-dimensional forms and the skin-friction has been calculated. The skin-friction decreases by increasing Hartmann number. The suction is applied to check the growth of the boundary layer. This study is likely to have bearing on the problem of boundary layer control and transpiration cooling. (author)

  20. Evaluation of the performance of solidified commercial low-level wastes in an arid climate

    International Nuclear Information System (INIS)

    Graham, M.J.; Walter, M.B.

    1984-01-01

    Shallow land burial is being used as a disposal method for commercial low-level waste at waste disposal sites in arid (Hanford, Washington) and humid (Barnwell, South Carolina) climatic regions. A field lysimeter facility has been established at Hanford in which to conduct waste-form leaching tests. The primary objective of this research is to determine typical source terms generated by commercial solidified low-level wastes. The field lysimeter facility consists of 10, 3 M deep by 1.8 M diameter, closed-bottomed lysimeters around a central 4 M deep by 4 M diameter instrument caisson. Commercial cement and dow polymer waste samples were removed from 210 L drums and placed in the 1.8 M diameter lysimeters. Two bitumen samples are planned to be emplaced in the facility this year. The central caisson provides access to the instrumentation in the individual lysimeters and allows selective sampling of the soil and waste forms. Suction candles (ceramic cups) placed around the waste will be used to periodically collect soil water samples for chemical analysis. Meteorological data, moisture content, and soil temperature are being automatically monitored at the facility. Characterization of the soils and waste forms have been partially completed. These data consist of moisture release characteristics, particle size distribution, concentrations and distributions of radionuclides in the waste streams, and concentrations of hydrophilic organic species in one of the waste streams

  1. The use of suction blisters to measure sunscreen protection against UVR-induced DNA damage.

    Science.gov (United States)

    Josse, Gwendal; Douki, Thierry; Le Digabel, Jimmy; Gravier, Eleonore; Questel, Emmanuel

    2018-02-01

    The formation of DNA photoproducts caused by solar UVR exposure needs to be investigated in-vivo and in particular in order to assess sunscreens' level of protection against solar genotoxicity. The study's purposes were: i) to evaluate if the roof of suction blisters is an appropriate sampling method for measuring photoproducts, and ii) to measure in-vivo sunscreen protection against cyclobutane pyrimidine dimers. Skin areas on the interior forearms of eight healthy volunteers were exposed in-vivo to 2 MED of simulated solar radiation (SSR) and to 15 MED on a sunscreen protected area. After irradiation, six suction blisters were induced and the blister roofs were collected. Analysis of SSR-induced CPDs was performed by two independent methods: a chromatography coupled to mass spectroscopy (HPLC-MS/MS) approach and a 3D-imaging of CPD immunostaining by multiphoton microscopy on floating epidermal sheets. HPLC-MS/MS analyses showed that SSR-unexposed skin presented no CPD dimers, whereas 2 MED SSR-exposed skin showed a significant number of TT-CPD. The sunscreen covered skin exposed to 15 MED appeared highly protected from DNA damage, as the amount of CPD-dimers remained below the detection limit. The multiphoton-immunostaining analysis consistently showed that no CPD staining was observed on the non-SSR-exposed skin. A significant increase of CPD staining intensity and number of CPD-positive cells were observed on the 2 MED SSR-exposed skin. Sunscreen protected skin presented a very low staining intensity and the number of CPD-positive cells remained very close to non-SSR-exposed skin. This study showed that suction blister samples are very appropriate for measuring CPD dimers in-vivo, and that sunscreens provide high protection against UVR-induced DNA damage. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. 玉砂利を使用したオープンケーソンに作用する周面摩擦に関する研究(IV)

    OpenAIRE

    中出, 睦; 五味, 信治; 加世田, 智成; 風間, 秀彦

    2004-01-01

    The SS caisson (SPACE SYSTEM CAISSON) method fills the space (gap) between caisson circumference surface and country rock with the space gravel, and it is the open caisson method which gently installs the caisson only by the dead weight at the good accuracy by reducing skin friction resistance which depends on caisson circumference surface, while the stability of country rock is attempted. The following have been carried out : Until now field measurement and indoor model experiment of convent...

  3. Gage for gas flow measurement especially in gas-suction pipes

    International Nuclear Information System (INIS)

    Renner, K.; Stegmanns, W.

    1978-01-01

    The gage utilizes the differential pressure given by a differential pressure producer to generate, in a bypass, a partial gas flow measured by means of a direct-reading anemometer of windmill type. The partial gas flow is generated between pressure pick-up openings in the gas-suction pipe in front of a venturi insert and pressure pick-up openings at the bottleneck of the venturi insert. The reading of the anemometer is proportional to the main gas flow and independent of the variables of state and the properties of the gases to be measured. (RW) [de

  4. Entropy Generation in a Rotating Couette Flow with Suction/Injection

    Directory of Open Access Journals (Sweden)

    S. Das

    2015-05-01

    Full Text Available The present paper is concerned with an analytical study of entropy generation in viscous incompressible Couette flow with suction/injection in a rotating frame of reference. One of the plate is held at rest and the other one moves with an uniform velocity.The flow induced by the moving plate. An exact solution of governing equations has been obtained in closed form. The entropy generation number and the Bejan number are also obtained. The influences of each of the governing parameters on velocity, temperature, entropy generation and Bejan number are discussed with the help of graphs.

  5. Analgesic efficacy of lidocaine for suction-assisted lipectomy with tumescent technique under general anesthesia: a randomized, double-masked, controlled trial.

    Science.gov (United States)

    Danilla, Stefan; Fontbona, Montserrat; de Valdés, Victoria Diaz; Dagnino, Bruno; Sorolla, Juan Pablo; Israel, Guillermo; Searle, Susana; Norambuena, Hernán; Cabello, Rodrigo

    2013-08-01

    Suction-assisted lipectomy is one of the most common procedures performed in plastic surgery. To minimize blood loss and to obtain adequate analgesia, a liquid solution is infiltrated into the subcutaneous plane before suction. The objective of this study was to determine whether the use of lidocaine in the infiltration solution reduces postoperative pain. A prospective, randomized, double-masked, clinical trial was designed. Each side of patients' body zones to be treated with suction-assisted lipectomy was randomized to receive infiltration solution with or without lidocaine. Treatment allocation was performed using computer-generated random numbers in permuted blocks of eight. Pain was assessed using the visual analogue scale and registered 1, 6, 12, 18, and 24 hours after the procedure. The trial was stopped after a first interim analysis. The use of lidocaine in the dilute solution reduced pain by 0.5 point on the visual analogue scale (95 percent CI, 0.3 to 0.8; p<0.001). The effect was independent of the suctioned body zone (p=0.756), and lasted until 18 hours after surgery. Its analgesic effect was lost at the 24-hour postoperative control. Pain increased an average of 0.018 point on the visual analogue scale per hour (95 percent CI, 0.001 to 0.036; p=0.043). The use of lidocaine in the infiltration solution is effective in postoperative pain control until 18 hours after surgery. Nevertheless, its clinical effect is limited and clinically irrelevant, and therefore it is no longer used by the authors. Therapeutic, I.

  6. 85,000-GPM, single-stage, single-suction LMFBR intermediate centrifugal pump

    International Nuclear Information System (INIS)

    Fair, C.E.; Cook, M.E.; Huber, K.A.; Rohde, R.

    1983-01-01

    The mechanical and hydraulic design features of the 85,000-gpm, single-stage, single-suction pump test article, which is designed to circulate liquid-sodium coolant in the intermediate heat-transport system of a Large-Scale Liquid Metal Fast Breeder Reactor (LS-LMFBR), are described. The design and analytical considerations used to satisfy the pump performance and operability requirements are presented. The validation of pump hydraulic performance using a hydraulic scale-model pump is discussed, as is the featute test for the mechanical-shaft seal system

  7. Flexible Electrostatic Technologies for Capture and Handling, Phase 1

    Science.gov (United States)

    Bryan, Thomas

    2015-01-01

    Fundamental to many of NASA's in-space transportation missions is the capture and handling of various objects and vehicles in various orbits for servicing, debris disposal, sample retrieval, and assembly without the benefit of sufficient grapple fixtures and docking ports. To perform similar material handling tasks on Earth, pincher grippers, suction grippers, or magnetic chucks are used, but are unable to reliably grip aluminum and composite spacecraft, insulation, radiators, solar arrays, or extra-terrestrial objects in the vacuum of outer space without dedicated handles in the right places. The electronic Flexible Electrostatic Technologies for space Capture and Handling (FETCH) will enable reliable and compliant gripping (soft dock) of practically any object in various orbits or surfaces without dedicated mechanical features, very low impact capture, and built-in proximity sensing without any conventional actuators. Originally developed to handle semiconductor and glass wafers during vacuum chamber processing without contamination, the normal rigid wafer handling chucks are replaced with thin metal foil segments laminated in flexible insulation driven by commercial off-the-shelf solid state, high-voltage power supplies. Preliminary testing in NASA Marshall Space Flight Center's (MSFC's) Flat Floor Robotics Lab demonstrated compliant alignment and gripping with a full-sized, 150-lb microsat mockup and translation before a clean release with a flip of a switch. The flexible electrostatic gripper pads can be adapted to various space applications with different sizes, shapes, and foil electrode layouts even with openings through the gripper pads for addition of guidance sensors or injection of permanent adhesives. With gripping forces estimated between 0.5 and 2.5 lb/in2 or 70-300 lb/ft2 of surface contact, the FETCH can turn on and off rapidly and repeatedly to enable sample handling, soft docking, in-space assembly, precision relocation, and surface translation

  8. A Prospective Randomized Study Comparing Manual and Wall Suction in the Performance of Bronchoalveolar Lavage.

    Science.gov (United States)

    Seijo, Luis M; Flandes, Javier; Somiedo, Maria V; Naya, Alba; Manjón, Josefina; Álvarez, Susana; Fernández-Navamuel, Iker

    2016-01-01

    Bronchoalveolar lavage (BAL) may be performed using a hand-held syringe or wall suction. The aim was to study BAL volume and diagnostic yields based on BAL technique. A total of 220 consecutive patients undergoing BAL at our center were included. Manual aspiration was performed in 115 patients (group 1), and wall suction (<50 mm Hg of negative pressure) was used in 105 patients (group 2). All bronchoscopies were performed under conscious sedation applying topical anesthesia with lidocaine. Three 50-ml sterile saline aliquots were instilled in all patients. The mean total amount of fluid recovered was 67 ± 20 ml in group 1 and 55 ± 22 ml in group 2 (p < 0.001). More patients in the manual aspiration group met American Thoracic Society criteria (recovery of ≥30% of instilled fluid) for an optimal BAL (81 vs. 59%; p < 0.001). The quantity of recovered fluid was also related to BAL location (p < 0.001) and radiologic findings (p = 0.002). Forty-eight (22%) BALs were diagnostic (23 in group 1 and 25 in group 2), including 37 positive bacterial cultures, 6 positive stains for Pneumocystis, and 5 cases of malignancy. No statistically significant difference in diagnostic yield was observed between the two groups. A BAL diagnosis was more likely in patients with certain radiologic (p = 0.033) and endoscopic findings (p = 0.001). When taking into account all bronchoscopic techniques performed during the procedure (e.g. biopsies, brushing, etc.), bronchoscopy was diagnostic in 37% of patients. Manual aspiration is superior to wall suction during BAL yielding a larger quantity of aspirate. Diagnostic yields are similar for both techniques. © 2016 S. Karger AG, Basel.

  9. Dispersion of suspended material from an operating sand suction dredge in the Øresund (Denmark)

    DEFF Research Database (Denmark)

    Kiørboe, Thomas; Møhlenberg, F.

    1981-01-01

    The concentration of suspended material in the immediate vicinity of an operating sand suction dredge in the Oresund was 3-5000mg/l. Concentrations > 100 mg/l were restricted to a downstream distance of .apprx. 150m and ambient levels were reached within .apprx. 1 km of the dredge. The natural...

  10. Capillary Suction Time. Operational Control Tests for Wastewater Treatment Facilities. Instructor's Manual [and] Student Workbook.

    Science.gov (United States)

    Wooley, John F.

    Capillary suction time is time required for the liquid phase of a treated sludge to travel through 1 centimeter of media (blotter or filter paper). Designed for individuals who have completed National Pollutant Discharge Elimination System (NPDES) level 1 laboratory training skills, this module provides waste water treatment plant operators with…

  11. Potential risk for bacterial contamination in conventional reused ventilator systems and disposable closed ventilator-suction systems.

    Science.gov (United States)

    Li, Ya-Chi; Lin, Hui-Ling; Liao, Fang-Chun; Wang, Sing-Siang; Chang, Hsiu-Chu; Hsu, Hung-Fu; Chen, Sue-Hsien; Wan, Gwo-Hwa

    2018-01-01

    Few studies have investigated the difference in bacterial contamination between conventional reused ventilator systems and disposable closed ventilator-suction systems. The aim of this study was to investigate the bacterial contamination rates of the reused and disposable ventilator systems, and the association between system disconnection and bacterial contamination of ventilator systems. The enrolled intubated and mechanically ventilated patients used a conventional reused ventilator system and a disposable closed ventilator-suction system, respectively, for a week; specimens were then collected from the ventilator circuit systems to evaluate human and environmental bacterial contamination. The sputum specimens from patients were also analyzed in this study. The detection rate of bacteria in the conventional reused ventilator system was substantially higher than that in the disposable ventilator system. The inspiratory and expiratory limbs of the disposable closed ventilator-suction system had higher bacterial concentrations than the conventional reused ventilator system. The bacterial concentration in the heated humidifier of the reused ventilator system was significantly higher than that in the disposable ventilator system. Positive associations existed among the bacterial concentrations at different locations in the reused and disposable ventilator systems, respectively. The predominant bacteria identified in the reused and disposable ventilator systems included Acinetobacter spp., Bacillus cereus, Elizabethkingia spp., Pseudomonas spp., and Stenotrophomonas (Xan) maltophilia. Both the reused and disposable ventilator systems had high bacterial contamination rates after one week of use. Disconnection of the ventilator systems should be avoided during system operation to decrease the risks of environmental pollution and human exposure, especially for the disposable ventilator system. ClinicalTrials.gov PRS / NCT03359148.

  12. Numerical simulation of effects of a non-ionized fluid injection and suction on the MHD flow in a circular channel

    International Nuclear Information System (INIS)

    Rahimi Eosboee, M.; Pourmahmoud, N.; Mirzaie, I.; Mohajeri Khameneh, P.; Majidyfar, S.

    2012-01-01

    Control of a fluid flow velocity profile by injection and suction of a non-ionized fluid in presence of a uniform steady magnetic field has important technical applications. In this paper, the unsteady incompressible and viscous conducting fluid flow has been investigated in a circular channel. The channel walls are assumed to be non-conducting and porous. They are subjected to a uniform steady magnetic field which is perpendicular to the axis of channel, then and suction and injection are applied at the walls. The well known equations of Magnetohydrodynamics are governed to the motion of an electrically conducting fluid flow that is subjected to magnetic field. The numerical solution is carried out by finite difference approach. The results of present numerical simulation shown that the flow injection and suction through the wall can be controlled effectively, the main flow in channel especially in industrial purposes. The results are obtained for different values of the injected and sucked non-ionized flow rate and the effect of Hartman number on the velocity profile is investigated. Finally, a good agreement is seen between the presented results and the corresponding data of finite element method.

  13. Impeller radial force evolution in a large double-suction centrifugal pump during startup at the shut-off condition

    International Nuclear Information System (INIS)

    Zou, Zhichao; Wang, Fujun; Yao, Zhifeng; Tao, Ran; Xiao, Ruofu; Li, Huaicheng

    2016-01-01

    Highlights: • Conclude the characteristics of transient radial force in the startup process for a large double-suction centrifugal pump. • The overall direction of the radial force during startup process is also confirmed. • A formula used to calculate the transient radial force during startup process is proposed. • A relationship between radial force variation and axial vortex development in blade channel during the startup process is established. The mechanism of the radial force evolution is revealed. - Abstract: Double-suction centrifugal pumps play an important role in the main feedwater systems of nuclear power plant. The impeller radial force in a centrifugal pump varies dramatically during startup at the shut-off condition. In this study, the startup process of a large double-suction centrifugal pump is investigated using CFD. During testing, the impeller speed is accelerated from zero to its rated speed in 1.0 s (marked as t_0) and is then maintained at the rated speed. The results show that the radial force increase lags behind the impeller speed increase. At 0–0.4t_0, the radial force is small (approaching zero). At 0.4–1.4t_0, the radial force increases rapidly. After 1.4t_0, the average radial force stabilizes and reaches its maximum value of 55,619 N. The observed maximum radial force value during startup is approximately nine times as high as the radial force under rated condition. During startup, the overall radial force direction is proximate to the radial line located 25° from the volute tongue along circumferential direction. A transient radial force formula is proposed to evaluate the changes in radial force during startup. The streamline distribution in impeller passages and the impeller outlet pressure profile varying over time are produced. The relationship between radial force evolution and the varying axial-to-spiral vortex structure is analyzed. The radial force change mechanism is revealed. This research provides a scientific

  14. Impeller radial force evolution in a large double-suction centrifugal pump during startup at the shut-off condition

    Energy Technology Data Exchange (ETDEWEB)

    Zou, Zhichao [College of Water Resources and Civil Engineering, China Agricultural University, Beijing 100083 (China); Wang, Fujun, E-mail: wangfj@cau.edu.cn [College of Water Resources and Civil Engineering, China Agricultural University, Beijing 100083 (China); Beijing Engineering Research Center of Safety and Energy Saving Technology for Water Supply Network System, China Agricultural University, Beijing 100083 (China); Yao, Zhifeng [College of Water Resources and Civil Engineering, China Agricultural University, Beijing 100083 (China); Beijing Engineering Research Center of Safety and Energy Saving Technology for Water Supply Network System, China Agricultural University, Beijing 100083 (China); Tao, Ran [College of Water Resources and Civil Engineering, China Agricultural University, Beijing 100083 (China); Xiao, Ruofu [College of Water Resources and Civil Engineering, China Agricultural University, Beijing 100083 (China); Beijing Engineering Research Center of Safety and Energy Saving Technology for Water Supply Network System, China Agricultural University, Beijing 100083 (China); Li, Huaicheng [Shanghai Liancheng (Group) Co., Ltd., Shanghai 201812 (China)

    2016-12-15

    Highlights: • Conclude the characteristics of transient radial force in the startup process for a large double-suction centrifugal pump. • The overall direction of the radial force during startup process is also confirmed. • A formula used to calculate the transient radial force during startup process is proposed. • A relationship between radial force variation and axial vortex development in blade channel during the startup process is established. The mechanism of the radial force evolution is revealed. - Abstract: Double-suction centrifugal pumps play an important role in the main feedwater systems of nuclear power plant. The impeller radial force in a centrifugal pump varies dramatically during startup at the shut-off condition. In this study, the startup process of a large double-suction centrifugal pump is investigated using CFD. During testing, the impeller speed is accelerated from zero to its rated speed in 1.0 s (marked as t{sub 0}) and is then maintained at the rated speed. The results show that the radial force increase lags behind the impeller speed increase. At 0–0.4t{sub 0}, the radial force is small (approaching zero). At 0.4–1.4t{sub 0}, the radial force increases rapidly. After 1.4t{sub 0}, the average radial force stabilizes and reaches its maximum value of 55,619 N. The observed maximum radial force value during startup is approximately nine times as high as the radial force under rated condition. During startup, the overall radial force direction is proximate to the radial line located 25° from the volute tongue along circumferential direction. A transient radial force formula is proposed to evaluate the changes in radial force during startup. The streamline distribution in impeller passages and the impeller outlet pressure profile varying over time are produced. The relationship between radial force evolution and the varying axial-to-spiral vortex structure is analyzed. The radial force change mechanism is revealed. This research

  15. Laterally Loaded Single Pile Response Considering the Influence of Suction and Non-Linear Behaviour of Reinforced Concrete Sections

    Directory of Open Access Journals (Sweden)

    Stefano Stacul

    2017-12-01

    Full Text Available A hybrid BEM-p-y curves approach was developed for the single pile analysis with free/fixed head restraint conditions. The method considers the soil non-linear behaviour by means of p-y curves in series to a multi-layered elastic half-space. The non-linearity of reinforced concrete pile sections, also considering the influence of tension-stiffening, has been considered. The model reproduces the influence of suction by increasing the stress state and hence the stiffness of shallow soil-layers. Suction is modeled using the Modified-Kovacs model. The hybrid BEM-py curves method was validated by comparing results from data of 22 load tests on single piles. In addition, a detailed comparison is presented between measured and computed data on a large-diameter reinforced concrete bored single pile.

  16. Construction method for plant facility

    International Nuclear Information System (INIS)

    Ito, Arata; Hirono, Hideharu; Kyoda, Shigeru; Hanawa, Minoru; Sato, Hitoshi

    1998-01-01

    A caisson structure is disposed on a construction site for facilities of nuclear power plants. A digging work is performed below the caisson structure and, simultaneous with the digging work, a construction of a base, construction of plant facilities including a building and installation of plant facility are performed on the caisson structure. Then, the caisson structure is sank together with the structures on a base rock in association with the progress of the digging work and secured on the base rock. When securing them on the base rock, a groove is formed to the base rock along tuyere of the caisson structure so that the tuyere and a ceiling portion of the caisson structure are in direct contact with the base rock. Since the construction for the containing building conducted on the caisson structure is performed simultaneous with the digging work conducted below the caisson structure, the term required for the construction of the plant facilities can greatly reduced. (N.H.)

  17. The impact analysis of the connecting pipe length and diameter on the operation of a piston hybrid power machine of positive displacement with gas suction capacity

    Science.gov (United States)

    Shcherba, V. E.; Grigoriev, A. V.; Averyanov, G. S.; Surikov, V. I.; Vedruchenko, V. P.; Galdin, N. S.; Trukhanova, D. A.

    2017-08-01

    The article analyzes the impact of the connecting liquid pipe length and diameter on consumables and power characteristics of the piston hybrid power machine with gas suction capacity. The following operating characteristics of the machine were constructed and analyzed: the average height of the liquid column in the jacket space; instantaneous velocity and height of the liquid column in the jacket space; the relative height of the liquid column in the jacket space; volumetric efficiency; indicator isothermal efficiency; flowrate in the pump section; relative pressure losses during suction; relative flowrate. The dependence of the instantaneous pressure in the work space and the suction space of the compressor section on the rotation angle of the crankshaft is determined for different values of the length and diameter of the connecting pipeline.

  18. Heat performance resulting from combined effects of radiation and mixed convection in a rectangular cavity ventilated by injection or suction

    Science.gov (United States)

    Ezzaraa, K.; Bahlaoui, A.; Arroub, I.; Raji, A.; Hasnaoui, M.; Naïmi, M.

    2018-05-01

    In this work, we investigated numerically heat transfer by mixed convection coupled to thermal radiation in a vented rectangular enclosure uniformly heated from below with a constant heat flux. The fresh fluid is admitted into the cavity by injection or suction, by means of two openings located on the lower part of both right and left vertical sides. Another opening is placed on the middle of the top wall to ensure the ventilation. Air, a radiatively transparent medium, is considered to be the cooling fluid. The inner surfaces, in contact with the fluid, are assumed to be gray, diffuse emitters and reflectors of radiation with identical emissivities. The effects of some pertinent parameters such as the Reynolds number, 300 ≤ Re ≤ 5000, and the emissivity of the walls, 0 ≤ ɛ ≤ 0.85, on flow and temperature patterns as well as on the heat transfer rate within the enclosure are presented for the two ventilation modes (injection and suction). The results indicate that the flow and thermal structures are affected by the thermal radiation for the two modes of imposed flow. However, the suction mode is found to be more favorable to the heat transfer in comparison with the injection one.

  19. Evaluation of the performance of solidified commercial low-level wastes in an arid climate

    International Nuclear Information System (INIS)

    Graham, M.J.; Walter, M.B.

    1984-09-01

    Shallow land burial is being used as a disposal method for commercial low-level waste at waste disposal sites in arid (Hanford site near Richland, Washington) and humid (Barnwell, South Carolina) climatic regions. A field lysimeter facility has been established at the Hanford site in which to conduct waste-form leaching tests. The primary objective of this research is to determine typical source terms generated by commercial solidified low-level wastes. The field lysimeter facility consists of ten 3-m-deep by 1.8-m-diameter, closed-bottom lysimeters around a central instrument caisson, 4 m in diameter. Commercial cement and vinyl ester-styrene waste samples were removed from 210-L drums and placed in the 1.8-m-diameter lysimeters. Two bitumen samples are planned to be emplaced in the facility in 1984. The central caisson provides access to the instrumentation in the individual lysimeters and allows selective sampling of the soil and waste forms. Suction candles (ceramic cups) placed around the waste will be used to periodically collect soil water samples for chemical analysis. Meteorological data, moisture content, and soil temperature are automatically monitored at the facility. Characterization of the soils and waste forms have been partially completed. These data consist of moisture release characteristics, particle size distribution, concentrations and distributions of radionuclides in the waste forms, concentrations of radionuclides in the waste streams, and concentrations of hydrophilic organic species in one of the waste steams. 8 references, 3 figures, 5 tables

  20. Aphids of the genus Diuraphis caught by Johnson suction trap in Poznań, Poland

    Directory of Open Access Journals (Sweden)

    Strażyński Przemysław

    2016-12-01

    Full Text Available In 1973-2011 in Poznań, aphid catches were carried out using Johnson’s suction trap. Since then the suction trap located at the Institute of Plant Protection - National Research Institute in Poznań has continuously recorded the daily and seasonal dynamics of aphid flights. The collected results has been used to establish one of the largest databases of this type in Europe. The data also allow tracking changes in aphid biodiversity under the changing climatic conditions. Three aphid species of Diuraphis spp. were identified: D. muehlei (Börner, 1950 - in 1974, D. bromicola (Hille Ris Lambers, 1959 - in 1988, D. noxia (Kurdjumov, 1913 - in 2003 as a result of systematic and long-term aphid collections. The occurrence of D. noxia presents a particular risk to cereal crops in Poland. This expansive aphid species that originates from Asia and the Mediterranean is a vector of Barley yellow dwarf viruses (BYDV, and has become one of the most important pest of wheat and barley in the world. Changes in climatic conditions that have been observed in recent years in Poland such as hot summer, long and warm autumn, mild winter seem to be optimal for occurrence and development of aphid species from warmer parts of Europe.

  1. Comparison between autologous blood transfusion drainage and closed-suction drainage/no drainage in total knee arthroplasty: a meta-analysis.

    Science.gov (United States)

    Hong, Kun-Hao; Pan, Jian-Ke; Yang, Wei-Yi; Luo, Ming-Hui; Xu, Shu-Chai; Liu, Jun

    2016-08-01

    Autologous blood transfusion (ABT) drainage system is a new unwashed salvaged blood retransfusion system for total knee replacement (TKA). However, whether to use ABT drainage, closed-suction (CS) drainage or no drainage in TKA surgery remains controversial. This is the first meta-analysis to assess the clinical efficiency, safety and potential advantages regarding the use of ABT drains compared with closed-suction/no drainage. PubMed, Embase, and the Cochrane Library were comprehensively searched in March 2015. Fifteen randomized controlled trials (RCTs) were identified and pooled for statistical analysis. The primary outcome evaluated was homologous blood transfusion rate. The secondary outcomes were post-operative haemoglobin on days 3-5, length of hospital stay and wound infections after TKA surgery. The pooled data included 1,721 patients and showed that patients in the ABT drainage group might benefit from lower blood transfusion rates (16.59 % and 37.47 %, OR: 0.28 [0.14, 0.55]; 13.05 % and 16.91 %, OR: 0.73 [0.47,1.13], respectively). Autologous blood transfusion drainage and closed-suction drainage/no drainage have similar clinical efficacy and safety with regard to post-operative haemoglobin on days 3-5, length of hospital stay and wound infections. Autologous blood transfusion drainage offers a safe and efficient alternative to CS/no drainage with a lower blood transfusion rate. Future large-volume high-quality RCTs with extensive follow-up will affirm and update this system review.

  2. Diagnostic Value of Endometrial Sampling with Pipelle Suction Curettage for Identifying Endometrial Lesions in Patients with Abnormal Uterine Bleeding

    Directory of Open Access Journals (Sweden)

    F Behnamfar

    2004-06-01

    Full Text Available Background: While determining the cause of abnormal uterine bleeding, sampling from the endometrium is necessary. Considering that pipelle suction curettage can be performed on an out patient basis and does not require hospitalization, using anesthesia and cervical dilatation, we performed this study. The aim of this study was to compare the diagnostic value of dilatation and curettage (D&C with pipelle suction curettage. Methods: This study was quasiexperimental on 200 pre and postmenopausal patients with abnormal uterine bleeding who refered to Shabihkhani hospital in Kashan, Iran. Endometrial sampling was performed in all patients with two methods namely pipelle and D&C. A pathologist examined the samples each having a predetermined code. Results: The mean age of subjects was 46.2 ±6.2 years, minimum age was 35 years and the maximum was 70 years. The various pathological lab findings were proliferative endometrium, secretory endometrium, athrophic, decidua, cystic and adenomatous hyperplasia. The reports were the same in two methods except for 2 cases where they were different: secretory endometrium with D&C but cystic hyperplasia in pipelle method. Conclusions: The result of our study shows the comparability of obtaining endometrial sample by pipelle with D&C. Due to comfort and convenience of patients in pipelle methode especially in the office setting which does not need anesthesia, pipelle method can easily be employed instead of D&C. Keywords: Pipelle Suction Curette, Dilatation and Curettage, Premenopause, Postmenopause.

  3. Unsteady flow of an incompressible fluid in a horizontal porous medium with suction

    International Nuclear Information System (INIS)

    Bestman, A.R.

    1988-04-01

    A theoretical analysis of two-dimensional unsteady flow in a porous medium bounded by a horizontal wall is presented as a perturbation on a basic flow. It is assumed that the perturbation is occasioned by a sudden suction at the wall. Even for a highly permeable medium the characteristic Reynolds number in porous media flow is usually small and asymptotic solutions are developed by the Laplace transform technique. It is observed that the perturbed shear stress at the wall decays exponentially with time. (author). 5 refs

  4. High negative pressure subcutaneous suction drain for managing debilitating subcutaneous emphysema secondary to tube thoracostomy for an iatrogenic post computed tomography guided transthoracic needle biopsy pneumothorax: Case report and review of literature.

    Science.gov (United States)

    Ahmed, Zeeshan; Patel, Pinakin; Singh, Suresh; Sharma, Raj Govind; Somani, Pankaj; Gouri, Abdul Rauf; Singh, Shiv

    2016-01-01

    Subcutaneous emphysema is a common complication of tube thoracostomy. Though self-limiting, it should be treated when it causes palpebral closure, dyspnea, dysphagia or undue disfigurement resulting in anxiety and distress to the patient. A 72year old man who was a known case of COPD on bronchodilators developed a large pneumothorax and respiratory distress after a CT guided transthoracic lung biopsy done for a lung opacity (approx. 3×3cm) at the right hilar region on Chest X-ray. Within 24h of an urgent tube thoracostomy, patient developed intractable subcutaneous emphysema with closure of palpebral fissure and dyspnea unresponsive to increasing suction on chest tube. A subcutaneous fenestrated drain was placed mid-way between the nipple and clavicle in the mid-clavicular line bilaterally. Continuous negative suction (-150mmHg) resulted in immediate, sustained relief and complete resolution within 5days. Extensive and debilitating SE (subcutaneous emphysema) has to be treated promptly to relieve patient discomfort, dysphagia or imminent respiratory compromise. A variety of treatment have been tried including infraclavicular blow-hole incisions, subcutaneous drains +/- negative pressure suction, fenestrated angiocatheters, Vacuum assisted dressings and increasing suction on a pre-existing chest tube. We describe a high negative pressure subcutaneous suction drain which provides immediate and sustained relief in debilitating SE. Debilitating subcutaneous emphysema which causes distress, anxiety, palpebral closure, dyspnoea or dysphagia requires intervention. High negative pressure subcutaneous suction drain provides immediate and sustained relief in extensive and debilitating SE. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  5. Controlling the Flow past a Semicircular Airfoil at Zero Angle of Attack Using Slot Suction in One or Two Vortex Cells for Attaining Extremal Lift

    Science.gov (United States)

    Isaev, S. A.; Baranov, P. A.; Sudakov, A. G.; Popov, I. A.; Usachov, A. E.

    2017-12-01

    Calculations using multiblock computational technologies and a model of shear-stress transport modified with allowance for the curvature of streamlines in turbulent airflow were performed at a zero angle of attack for a semicircular airfoil containing one or two surface vortex cells with slot suction. The results showed evidence of stabilization of a nearly undetached flow and attainment of an extremal lift of C y = 5.2 and a lift-to-drag ratio of K = 24 with allowance for energy losses for suction in the vortex cells.

  6. History of Suction-Type Laminar-Flow Control with Emphasis on Flight Resrearch: Monographs in Aerospace History Number 13

    Science.gov (United States)

    Braslow, A. L.

    1999-01-01

    The paper contains the following sections: Foreword; Preface; Laminar-Flow Control Concepts and Scope of Monograph; Early Research on Suction-Type Laminar-Flow Control (Research from the 1930s through the War Years; Research from after World War II to the Mid-1960s); Post X-21 Research on Suction-Type Laminar-Flow Control; Status of Laminar-Flow Control Technology in the Mid-1990s; Glossary; Document 1-Aeronautics Panel, AACB, R&D Review, Report of the Subpanel on Aeronautic Energy Conservation/Fuels; Document 2-Report of Review Group on X-21A Laminar Flow Control Program; Document 3-Langley Research Center Announcement, Establishment of Laminar Flow Control Working Group; Document 4-Intercenter Agreement for Laminar Flow Control Leading Edge Glove Flights, LaRC and DFRC; Document 5-Flight Report NLF-144, of AFTIF-111 Aircraft with the TACT Wing Modified by a Natural Laminar Flow Glove; Document 6-Flight Record, F-16XL Supersonic Laminar Flow Control Aircraft; Index; and About the Author.

  7. Suction blister grafting - Modifications for easy harvesting and grafting

    Directory of Open Access Journals (Sweden)

    2012-01-01

    Full Text Available Suction blister grafting is a simple modality of treatment of patients with resistant and stable vitiligo. But raising the blisters may be time consuming and transferring to the recipient site may be difficult as the graft is ultrathin. By doing some modifications we can make the technique simpler and easier. We can decrease the blister induction time by intradermal injection of saline, exposure to Wood′s lamp, intrablister injection of saline. By these methods we can decrease the blister induction time from 2-3 hrs to 45-90 minutes. After harvesting the graft, it can be transferred to the recipient area by taking the graft on a sterile glass slide, on the gloved finger, rolling the graft over a sterile syringe and then spreading on the recipient area, or taking on the sterile wrapper of paraffin dressing and then placing over the recipient area.

  8. Fastest predators in the plant kingdom: functional morphology and biomechanics of suction traps found in the largest genus of carnivorous plants

    Science.gov (United States)

    Poppinga, Simon; Weisskopf, Carmen; Westermeier, Anna Sophia; Masselter, Tom; Speck, Thomas

    2016-01-01

    Understanding the physics of plant movements, which describe the interplay between plant architecture, movement speed and actuation principles, is essential for the comprehension of important processes like plant morphogenesis. Recent investigations especially on rapid plant movements at the interface of biology, physics and engineering sciences highlight how such fast motions can be achieved without the presence of muscles, nerves and technical hinge analogies. The suction traps (bladders) of carnivorous bladderworts (Utricularia spp., Lentibulariaceae, Lamiales) are considered as some of the most elaborate moving structures in the plant kingdom. A complex interplay of morphological and physiological adaptations allows the traps to pump water out of their body and to store elastic energy in the deformed bladder walls. Mechanical stimulation by prey entails opening of the otherwise watertight trapdoor, followed by trap wall relaxation, sucking in of water and prey, and consecutive trapdoor closure. Suction can also occur spontaneously in non-stimulated traps. We review the current state of knowledge about the suction trap mechanism with a focus on architectonically homogeneous traps of aquatic bladderwort species from section Utricularia (the so-called ‘Utricularia vulgaris trap type’). The functional morphology and biomechanics of the traps are described in detail. We discuss open questions and propose promising aspects for future studies on these sophisticated ultra-fast trapping devices. PMID:26602984

  9. An Iterative Method to Derive the Equivalent Centrifugal Compressor Performance at Various Operating Conditions: Part I: Modelling of Suction Parameters Impact

    Directory of Open Access Journals (Sweden)

    Waleed Albusaidi

    2015-08-01

    Full Text Available This paper introduces a new iterative method to predict the equivalent centrifugal compressor performance at various operating conditions. The presented theoretical analysis and empirical correlations provide a novel approach to derive the entire compressor map corresponding to various suction conditions without a prior knowledge of the detailed geometry. The efficiency model was derived to reflect the impact of physical gas properties, Mach number, and flow and work coefficients. One of the main features of the developed technique is the fact that it considers the variation in the gas properties and stage efficiency which makes it appropriate with hydrocarbons. This method has been tested to predict the performance of two multistage centrifugal compressors and the estimated characteristics are compared with the measured data. The carried comparison revealed a good matching with the actual values, including the stable operation region limits. Furthermore, an optimization study was conducted to investigate the influences of suction conditions on the stage efficiency and surge margin. Moreover, a new sort of presentation has been generated to obtain the equivalent performance characteristics for a constant discharge pressure operation at variable suction pressure and temperature working conditions. A further validation is included in part two of this study in order to evaluate the prediction capability of the derived model at various gas compositions.

  10. Exact solution for flow in a porous pipe with unsteady wall suction and/or injection

    Science.gov (United States)

    Tsangaris, S.; Kondaxakis, D.; Vlachakis, N. W.

    2007-10-01

    This paper presents an extension of the exact solution of the steady laminar axisymmetric flow in a straight pipe of circular cross section with porous wall, given by R.M. Terrill, to the case of unsteady wall injection and/or suction. The cases of the pulsating parabolic profile and of the developed pulsating flow are investigated as examples. The pulsating flow in porous ducts has many applications in biomedical engineering and in other engineering areas.

  11. Some Exact Solutions of Boundary Layer Flows along a Vertical Plate with Buoyancy Forces Combined with Lorentz Forces under Uniform Suction

    Directory of Open Access Journals (Sweden)

    Asterios Pantokratoras

    2008-01-01

    Full Text Available Exact analytical solutions of boundary layer flows along a vertical porous plate with uniform suction are derived and presented in this paper. The solutions concern the Blasius, Sakiadis, and Blasius-Sakiadis flows with buoyancy forces combined with either MHD Lorentz or EMHD Lorentz forces. In addition, some exact solutions are presented specifically for water in the temperature range of 0∘C≤≤8∘C, where water density is nearly parabolic. Except for their use as benchmarking means for testing the numerical solution of the Navier-Stokes equations, the presented exact solutions with EMHD forces have use in flow separation control in aeronautics and hydronautics, whereas the MHD results have applications in process metallurgy and fusion technology. These analytical solutions are valid for flows with strong suction.

  12. 75 FR 3731 - Proposed Issuance of a General NPDES Permit for Small Suction Dredging-Permit Number IDG-37-0000

    Science.gov (United States)

    2010-01-22

    ... System (NPDES) general permit to placer mining operations in Idaho for small suction dredges (intake... ENVIRONMENTAL PROTECTION AGENCY [FRL-9104-3] Proposed Issuance of a General NPDES Permit for Small... significant economic impact on a substantial number of small entities.'' EPA has concluded that NPDES general...

  13. Effect of thermal radiation and suction on convective heat transfer of nanofluid along a wedge in the presence of heat generation/absorption

    Energy Technology Data Exchange (ETDEWEB)

    Kasmani, Ruhaila Md; Bhuvaneswari, M. [Centre for Foundation Studies in Science, University of Malaya, 50603 Kuala Lumpur (Malaysia); Sivasankaran, S.; Siri, Zailan [Institute of Mathematical Science, University of Malaya, 50603 Kuala Lumpur (Malaysia)

    2015-10-22

    An analysis is presented to find the effects of thermal radiation and heat generation/absorption on convection heat transfer of nanofluid past a wedge in the presence of wall suction. The governing partial differential equations are transformed into a system of ordinary differential equations using similarity transformation. The resulting system is solved numerically using a fourth-order Runge–Kutta method with shooting technique. Numerical computations are carried out for different values of dimensionless parameters to predict the effects of wedge angle, thermophoresis, Brownian motion, heat generation/absorption, thermal radiation and suction. It is found that the temperature increases significantly when the value of the heat generation/absorption parameter increases. But the opposite observation is found for the effect of thermal radiation.

  14. Design of triaxial test with controlled suction: measure of strain

    International Nuclear Information System (INIS)

    Gasc-Barbier, M.; Cosenza, Ph.; Ghoreychi, M.; Chanchole, S.; Cosenza, Ph.; Tessier, D.

    2000-01-01

    Experimental study of mechanical behavior of clayey materials under hygrometric condition is usually performed either on unloaded samples or by means of classical odometer tests used in soil mechanics. Such methods are not well adapted to hard deep clayey rocks with little deformability, porosity and permeability. Moreover, stress and strain tensors having a significant effect on hygro-mechanical behaviour and properties cannot be measured and investigated appropriately by classical tests. This is why a specific triaxial test was designed in which the sample is surrounded by a fiber glass tissue allowing air circulation and then by silicon on which confining pressure is applied. Thus, equilibrium between air and sample was reduced. Stress and strain tensors were also measured in time on the sample subjected to a mechanical loading and to a controlled suction. After presentation of the test, preliminary results are given. (authors)

  15. How propeller suction is the dominant factor for ship accidents at shallow water conditions

    Science.gov (United States)

    Acar, Dursun; Alpar, Bedri; Ozeren, Sinan

    2017-04-01

    The laminar flow comes to the fore with the disappearance of the several other directions in the internal displacements in the water current. Due to the dominant speed direction during the straightforward motion of the ship, the underwater hull is associated with the continuous flow of laminar currents. The open marine environment acts as a compressible liquid medium because of the presence of many variables about water volume overflow boundaries where the ship is associated. Layers of water rising over the sea surface due to ship's body and the propeller's water push provides loss of liquid lifting force for the ship. These situations change the well-known sea-floor morphology and reliable depth limits, and lead to probable accidents. If the ship block coefficient for the front side is 0.7 or higher, the "squat" will be more on the bow, because the associated factor "displacement volume" causes to the low-pressure environment due to large and rapid turbulence. Thus, the bow sinks further, which faced with liquid's weaker lift force. The vessels Gerardus Mercator, Queen Elizabeth and Costa Concordia had accidents because of unified reasons of squat, fast water mass displacement by hull push and propeller suction interaction. In the case of water mass displacement from the bow side away, that accident occurred in 2005 by the vessel Gerardus Mercator with excessive longitudinal trim angularity in the shallow water. The vessel Costa Concordia (2012), voluminous water displaced from the rear left side was an important factor because of the sharp manoeuvre of that the captain made before the accident. Observations before the accident indicate that full-speed sharp turn provided listed position for the ship from left (port side) in the direction of travel before colliding and then strike a rock on the sloping side of the seabed. The reason why the ship drifted to the left depends mainly the water discharge occurred at the left side of the hull during left-hand rudder

  16. Effect of Suction Nozzle Pressure Drop on the Performance of an Ejector-Expansion Transcritical CO2 Refrigeration Cycle

    Directory of Open Access Journals (Sweden)

    Zhenying Zhang

    2014-08-01

    Full Text Available The basic transcritical CO2 systems exhibit low energy efficiency due to their large throttling loss. Replacing the throttle valve with an ejector is an effective measure for recovering some of the energy lost in the expansion process. In this paper, a thermodynamic model of the ejector-expansion transcritical CO2 refrigeration cycle is developed. The effect of the suction nozzle pressure drop (SNPD on the cycle performance is discussed. The results indicate that the SNPD has little impact on entrainment ratio. There exists an optimum SNPD which gives a maximum recovered pressure and COP under a specified condition. The value of the optimum SNPD mainly depends on the efficiencies of the motive nozzle and the suction nozzle, but it is essentially independent of evaporating temperature and gas cooler outlet temperature. Through optimizing the value of SNPD, the maximum COP of the ejector-expansion cycle can be up to 45.1% higher than that of the basic cycle. The exergy loss of the ejector-expansion cycle is reduced about 43.0% compared with the basic cycle.

  17. Flexibility.

    Science.gov (United States)

    Humphrey, L. Dennis

    1981-01-01

    Flexibility is an important aspect of all sports and recreational activities. Flexibility can be developed and maintained by stretching exercises. Exercises designed to develop flexibility in ankle joints, knees, hips, and the lower back are presented. (JN)

  18. [Comparison of the effects of the intervention with electric thermal bian stone and air suction cup on blood perfusion at meridian points].

    Science.gov (United States)

    Zhao, Pengna; Wang, Yanping; Gu, Feifei; Li, Chaozheng; Wei, Yulong; Wang, Guangjun; Zhang, Weibo

    2018-02-12

    To observe the impacts of the intervention with electric thermal bian stone and air suction cup on blood perfusion (BP) at meridian points and explore the approach of accurate measurement and regulation of meridian qi and blood balance in "precise acupuncture". The laser Doppler line scanner (LDLS) was used to measure BP at bilateral yua n-primary points at the pericardium meridian, the triple energizer meridian, the gallbladder meridian and the liver meridian (small cycle of jueyin to shaoyang meridians) at 31 healthy receptors. The bias ratio of blood perfusion (BPBR) deviated to the reference value was calculated. The electric thermal bian stone and air suction cup were used in the intervention at the he -sea points of the affected meridians in which BPBR was relatively higher at the yuan -primary points. The electric thermal bian stone therapy was used when BPBR was less than -30% and the air suction cupping therapy was used when BPBR was higher than 30%. BP was measured twice before intervention and it was measured separately at the moment after intervention and in 20 min after intervention. The means of BP before and after intervention and the change ratio of blood perfusion (BPCR) before intervention, at the moment after intervention and 20 min after intervention were calculated. 1. After the intervention of electric thermal bian stone, BP mean was increased from (103.51±41.21) PU to (121.97±56.22) PU ( P 0.05), but the change ratio was highly remained. 2. After intervention with air suction cup, BP mean was reduced from (194.83±81.14) PU to (173.88±88.26) PU. Before intervention, at the moment after intervention and 20 min after intervention, separately, BPCR were (7.62±30.49)%, (-12.12±18.20)% and (-14.35±21.25)%. BPCR at the moment after intervention and in 20 min after intervention were significantly different from that before intervention (both P cup is opposite.

  19. AUTOMATIC CONTROL SYSTEM OF THE DIFFERENCE BETWEEN DISCHARGE AND SUCTION PRESSURES OF THE HEAT PUMP STATION COMPRESSOR

    Directory of Open Access Journals (Sweden)

    Sit M.L.

    2009-04-01

    Full Text Available Possibility of realization is shown and the control system of a difference of pressure between an exit and an input of the compressor of the heat pump on carbon dioxide working at variable thermal load, and discharge and suction pressures by means of two control valves connected in series is developed. On an example a flow coefficient calculation procedure of control valves is shown.

  20. Blood lactate changes in men during graded workloads at normal atmospheric pressure (100 kPa) and under simulated caisson conditions (400 kPa).

    Science.gov (United States)

    Neubauer, B; Tetzlaff, K; Buslaps, C; Schwarzkopf, J; Bettinghausen, E; Rieckert, H

    1999-05-01

    A hyperbaric environment may influence lactate metabolism due to hyperoxia affecting biochemical pathways. The purpose of our study was to determine the blood lactate levels occurring at high workloads in a sample of professional divers under simulated caisson conditions. The ambient air pressure was equivalent to a diving depth of 30 m of seawater (400 kPa). A total of 23 healthy male subjects performed graded bicycle exercise in a dry hyperbaric chamber up to a maximum of 3.5 W kg(-1) body weight at normal (100 kPa) and elevated ambient air pressure (400 kPa). The blood lactate level and the heart rate were measured. In comparison with control conditions, the heart rate and the peripheral blood lactate level were significantly lower at depth for all workloads. The differences between the normobaric and hyperbaric lactate values may be explained by an overall improvement in lactate metabolism at elevated ambient pressure, especially in the working muscles and the organs responsible for the lactate reduction, i.e., the liver. The reduced heart rate may be an effect of the improved tissue oxygen supply at depth.

  1. Unsteady three dimensional flow of Casson liquid film over a porous stretching sheet in the presence of uniform transverse magnetic field and suction/injection

    Energy Technology Data Exchange (ETDEWEB)

    Maity, S., E-mail: susantamaiti@gmail.com [Department of Mathematics, National Institute of Technology, Arunachal Pradesh, Yupia, Papumpare 791112 (India); Singh, S.K. [Engineering Mechanics Unit, Jawaharlal Nehru Centre for Advanced Scientific Research, Bangalore 560064 (India); Kumar, A.V. [Department of Mathematics, National Institute of Technology, Arunachal Pradesh, Yupia, Papumpare 791112 (India)

    2016-12-01

    Three dimensional flow of thin Casson liquid film over a porous unsteady stretching sheet is investigated under assumption of initial uniform film thickness. The effects of the uniform transverse magnetic field, suction and injection are also considered for investigation. The nonlinear governing set of equations and film evolution equation are solved analytically by using singular perturbation technique. It is found that the film thickness decreases with the increasing values of the Casson parameter. The Hartmann number and porosity parameter resist the film thinning process. It is also observed that the film thickness increases with the increasing values of the suction velocity whereas it decreases for increasing values of the injection velocity at the stretching surface.

  2. Beneficial effects of intermittent suction and pressure treatment in intermittent claudication

    DEFF Research Database (Denmark)

    Mehlsen, J; Himmelstrup, H; Himmelstrup, Bodil

    1993-01-01

    administration. The treatment caused significant increments in the ADP thresholds for platelet aggregation, while the effects on fibrinolysis were uncertain. It is concluded that intermittent suction and pressure treatment offers a new approach for conservative treatment of intermittent claudication....... participated in an open trial investigating the possible effects of the treatment on platelet aggregation and fibrinolysis. Pain-free and maximal walking distances were measured on a treadmill, and systolic blood pressure was measured on the upper limb, the ankle, and the first toe bilaterally. The threshold...... for adenosine diphosphate (ADP)-induced platelet aggregation was tested, and the fibrinolytic activity was estimated from the euglobulin clot lysis time. Active treatment resulted in significant improvements in pain-free and maximal walking distances, whereas no changes could be found during placebo...

  3. The radiation and variable viscosity effects on electrically conducting fluid over a vertically moving plate subjected to suction and heat flux

    Energy Technology Data Exchange (ETDEWEB)

    Malekzadeh, P., E-mail: malekzadeh@pgu.ac.i [Department of Mechanical Engineering, Persian Gulf University, Bushehr 75168 (Iran, Islamic Republic of); Center of Excellence for Computational Mechanics, Shiraz University, Shiraz (Iran, Islamic Republic of); Moghimi, M.A. [Department of Mechanical Engineering, School of Engineering, Shaid Bahonar University, Kerman (Iran, Islamic Republic of); Nickaeen, M. [K.N. Toosi University of Technology, Tehran (Iran, Islamic Republic of)

    2011-05-15

    Research highlights: {yields} A new application of the differential quadrature method in thermo-fluid fields. {yields} Moving vertical plate with suction and heat flux is considered. {yields} Fluid with variable viscosity subjected to thermal radiation is studied. -- Abstract: In this paper, firstly, the applicability of the differential quadrature method (DQM) as an efficient and accurate numerical method for solving the problem of variable viscosity and thermally radiative unsteady magneto-hydrodynamic (MHD) flow over a moving vertical plate with suction and heat flux is investigated. The spatial as well as the temporal domains are discretized using the DQM. The fast rate of convergence of the method is demonstrated and for the cases that a solution is available, comparison is done. Then, effects of the temperature dependence of viscosity and different fluid parameters on the velocity and temperature of transient MHD flow subjected to the above mentioned boundary condition are studied.

  4. Reevaluating Musculoskeletal Linkages in Suction-Feeding Fishes with X-Ray Reconstruction of Moving Morphology (XROMM).

    Science.gov (United States)

    Camp, Ariel L; Brainerd, Elizabeth L

    2015-07-01

    Suction-feeding fishes encompass a vast diversity of morphologies and ecologies, but during feeding they all rely on musculoskeletal linkages and levers to transform the shortening of muscle into 3D expansion of the mouth cavity. To relate the shape of these skeletal elements to their function in expansion of the mouth, four-bar linkage models have been developed and widely used in studies of ecology, evolution, and development. However, we have lacked the ability to test the predictions of these 2D linkage models against the actual 3D motions of fishes' skulls. A new imaging method, X-ray Reconstruction of Moving Morphology (XROMM), now makes it possible to measure 3D skeletal motions relative to other bones within the head and relative to the fish's body, and thereby to examine directly the proposed linkages. We used XROMM to examine the opercular linkage, in which shortening of the levator operculi muscle is hypothesized to retract the operculum, and thereby the interoperculum and interoperculomandibular ligament to generate depression of the lower jaw about the quadratomandibular joint. XROMM animations of suction strikes in largemouth bass revealed that the operculum is indeed retracted relative to the suspensorium as the levator operculi muscle shortens and the jaw depresses. However, the four-bar model of this linkage overestimates the depression of the jaw by nearly a factor of two. Therefore, caution should be used in interpreting and applying the predictions of this linkage model. When we measured kinematics relative to the fish's body, we found that the operculum was relatively stable, whereas the suspensorium was elevated along with the neurocranium, pushing the quadratomandibular joint forward to produce depression of the jaw. Thus, it is the epaxial muscles elevating the neurocranium that powers depression of the jaw through the opercular linkage. However, the levator operculi muscle plays a crucial role in stabilizing the operculum to allow elevation

  5. A Numerical Study on the Improvement of Suction Performance and Hydraulic Efficiency for a Mixed-Flow Pump Impeller

    Directory of Open Access Journals (Sweden)

    Sung Kim

    2014-01-01

    Full Text Available This paper describes a numerical study on the improvement of suction performance and hydraulic efficiency of a mixed-flow pump by impellers. The design of these impellers was optimized using a commercial CFD (computational fluid dynamics code and DOE (design of experiments. The design variables of meridional plane and vane plane development were defined for impeller design. In DOE, variables of inlet part were selected as main design variables in meridional plane, and incidence angle was selected in vane plane development. The verification of the experiment sets that were generated by 2k factorial was done by numerical analysis. The objective functions were defined as the NPSHre (net positive suction head required, total efficiency, and total head of the impellers. The importance of the geometric design variables was analyzed using 2k factorial designs. The interaction between the NPSHre and total efficiency, according to the meridional plane and incidence angle, was discussed by analyzing the 2k factorial design results. The performance of optimally designed model was verified by experiments and numerical analysis and the reliability of the model was retained by comparison of numerical analysis and comparative analysis with the reference model.

  6. Aero-thermal optimization of film cooling flow parameters on the suction surface of a high pressure turbine blade

    Science.gov (United States)

    El Ayoubi, Carole; Hassan, Ibrahim; Ghaly, Wahid

    2012-11-01

    This paper aims to optimize film coolant flow parameters on the suction surface of a high-pressure gas turbine blade in order to obtain an optimum compromise between a superior cooling performance and a minimum aerodynamic penalty. An optimization algorithm coupled with three-dimensional Reynolds-averaged Navier Stokes analysis is used to determine the optimum film cooling configuration. The VKI blade with two staggered rows of axially oriented, conically flared, film cooling holes on its suction surface is considered. Two design variables are selected; the coolant to mainstream temperature ratio and total pressure ratio. The optimization objective consists of maximizing the spatially averaged film cooling effectiveness and minimizing the aerodynamic penalty produced by film cooling. The effect of varying the coolant flow parameters on the film cooling effectiveness and the aerodynamic loss is analyzed using an optimization method and three dimensional steady CFD simulations. The optimization process consists of a genetic algorithm and a response surface approximation of the artificial neural network type to provide low-fidelity predictions of the objective function. The CFD simulations are performed using the commercial software CFX. The numerical predictions of the aero-thermal performance is validated against a well-established experimental database.

  7. Verification of new technologies introduced into the privately-owned port of Higashidori Nuclear Power Station

    International Nuclear Information System (INIS)

    Murano, Sei-ichiro; Ozaki, Tsutomu; Date, Masanao

    2005-01-01

    The privately-owned port of Higashidori Nuclear Power Station introduced the rubble-slopping breakwater as the seawall and the concrete-caisson breakwater (new caisson breakwater) as the outlet seawall. The distribution of wave pressure on the new caisson breakwater was measured by the wave pressure meteor set on it and compared with the results of the hydraulic model tests. The precast concrete armour unit used Acropod. The conditions of new caisson breakwater, measurement of wave pressure, and the optimum conditions of seawall are stated. The new caisson breakwater showed the high dispersive effect of the impact wave force on the surf zone. The construction cost was decreased by reduction of sectional area and the wave dissipating concrete block. There are no problems about the stability of breakwater confirmed by the hydraulic model test. (S.Y.)

  8. Flexible Bronchoscopy.

    Science.gov (United States)

    Miller, Russell J; Casal, Roberto F; Lazarus, Donald R; Ost, David E; Eapen, George A

    2018-03-01

    Flexible bronchoscopy has changed the course of pulmonary medicine. As technology advances, the role of the flexible bronchoscope for both diagnostic and therapeutic indications is continually expanding. This article reviews the historical development of the flexible bronchoscopy, fundamental uses of the flexible bronchoscope as a tool to examine the central airways and obtain diagnostic tissue, and the indications, complications, and contraindications to flexible bronchoscopy. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Cytoskeleton and pericellular matrix organization of pure adult human keratinocytes cultured from suction-blister roof epidermis.

    Science.gov (United States)

    Kariniemi, A L; Lehto, V P; Vartio, T; Virtanen, I

    1982-12-01

    Pure adult human keratinocyte cultures were raised from suction-blister roof epidermis and cultured in MCDB-151 medium. In primary culture the epidermal cells rapidly adhered, spread and began to proliferate on collagen-coated growth substrata but not on uncoated plastic or glass substrata. A fibrillar keratin-specific fluorescence, showing a typical cell-cell arrangement, was seen in all cells in indirect immunofluorescence microscopy, whereas only some cells also showed vimentin-specific staining. A fine fibrillar fibronectin-specific surface staining was seen at the margin of attaching cells and in marginal cells of spreading cell islands, whereas no fluorescence could be seen in epidermal cells, with antibodies against type IV collagen or laminin. Interestingly, the marginal cells also showed intracellular fibronectin. The synthesis of fibronectin in epidermal cell cultures could also be revealed by metabolic labelling experiments with [35S]methionine. In contrast to primary cultures, subcultivated keratinocytes also adhered to uncoated plastic and glass substrata. After subcultivation, keratin and surface fibronectin distribution remained unaltered but after some subcultivations, most of the cells also showed fibrillar vimentin and expressed fibronectin intracellularly. The results show that the suction-blister method provides an easy way to obtain pure epidermal cell cultures without contaminating mesenchymal cells. Our results also suggest a direct role for fibronectin but not for collagen type IV or laminin in adhesion and spreading of epidermal cells in vitro.

  10. Seasonal dynamics of nitrate and ammonium ion concentrations in soil solutions collected using MacroRhizon suction cups.

    Science.gov (United States)

    Kabala, Cezary; Karczewska, Anna; Gałka, Bernard; Cuske, Mateusz; Sowiński, Józef

    2017-07-01

    The aims of the study were to analyse the concentration of nitrate and ammonium ions in soil solutions obtained using MacroRhizon miniaturized composite suction cups under field conditions and to determine potential nitrogen leaching from soil fertilized with three types of fertilizers (standard urea, slow-release urea, and ammonium nitrate) at the doses of 90 and 180 kg ha -1 , applied once or divided into two rates. During a 3-year growing experiment with sugar sorghum, the concentration of nitrate and ammonium ions in soil solutions was the highest with standard urea fertilization and the lowest in variants fertilized with slow-release urea for most of the months of the growing season. Higher concentrations of both nitrogen forms were noted at the fertilizer dose of 180 kg ha -1 . One-time fertilization, at both doses, resulted in higher nitrate concentrations in June and July, while dividing the dose into two rates resulted in higher nitrate concentrations between August and November. The highest potential for nitrate leaching during the growing season was in July. The tests confirmed that the miniaturized suction cups MacroRhizon are highly useful for routine monitoring the concentration of nitrate and ammonium ions in soil solutions under field conditions.

  11. A similar solution for an unsteady free convection flow past an impulsively started vertical plate with mass transfer and suction or injection

    International Nuclear Information System (INIS)

    Sattar, M.A.

    1990-12-01

    A similar solution for the flow past a vertical plate started impulsively in its own plane in a viscous incompressible fluid is presented on taking into account the effects of variable suction and/or injection and mass transfer. To solve the momentum, energy and concentration equations, a time dependent length scale is introduced, which leads to the driving parameters γ(=G r /R σ 2 ) and γ*(=G r */R σ 2 ), where G r and G r * are respectively the Grashof and modified Grashof numbers while R σ is the Reynolds number. The resulting locally similar momentum equation is then solved by the method of superposition. The effects of the parameters and that of suction/injection on the flow and on the wall shear-stress of the plate are shown graphically for different values of Schmidt number and transpiration parameter. (author). 24 refs, 11 figs

  12. Comparison in processing routes by copper mold casting injection and suction in the Cu46Zr42Al7Y5 vitreous alloy

    International Nuclear Information System (INIS)

    Batalha, W.; Aliaga, L.C.R.; Bolfarini, C.; Botta, W.J.; Kiminami, C.S.

    2014-01-01

    To expand the application of glassy metals, the development of processing routes and compositions that allow the production of parts with dimensions of millimeters or even centimeters, is very important. The present work aims the contribution to the technological development of processing routes for the production of Cu-based bulk metallic glasses. Wedge-shaped samples of Cu 46 Zr 42 Al 7 Y 5 (atom percent) chemical composition were processed using copper mold casting by suction and injection. Characterization was made combining scanning electron microscopy, x-ray diffraction and differential scanning calorimetry. The critical amorphous thickness obtained by those two different routes was carefully observed. The suction route allow obtaining the best results with critical amorphous thickness about 8 mm. This result was analyzed considering the different extrinsic parameters to the glass forming ability of the alloy. (author)

  13. BWR 200 % recirculation pump suction line break LOCA tests, RUNs 942 and 943 at ROSA-III without HPCS

    International Nuclear Information System (INIS)

    Suzuki, Mitsuhiro; Tasaka, Kanji; Anoda, Yoshinari; Kumamaru, Hiroshige; Nakamura, Hideo; Yonomoto, Taisuke; Murata, Hideo; Koizumi, Yasuo

    1986-03-01

    This report presents the experimental results of RUNs 942 and 943 in ROSA-III program, which are 200 % recirculation pump suction line break LOCA tests with assumption of HPCS failure. The ROSA-III test facility simulates a BWR system with volume scale of 1/424 and has four half-length electrically heated fuel bundles, two active recirculation loops, ECCS's, and steam and feedwater systems. Effects of initial core void distribution and other fluid conditions on overall LOCA phenomena with special interest on transient core cooling phenomena were investigated by comparing the present test results with those of RUN 926, a 200 % suction line break test with standard initial fluid conditions. The initial core outlet quality was changed between 5 % and 43 %. As conclusions, (1) the initial lower core flow and higher void fraction affected significantly the core cooling conditions and resulted in earlier and higher PCT. (2) The lower plenum flashing temporarily contributed to cool down the core. (3) Flashing of remained hot water in the feedwater line affected slightly the pressure response and delayed the actuation of LPCI by 11 seconds. (4) The whole core was completely cooled down within 104 seconds after the LPCI actuation in these large break tests. (author)

  14. New fossil insect order Permopsocida elucidates major radiation and evolution of suction feeding in hemimetabolous insects (Hexapoda: Acercaria).

    Science.gov (United States)

    Huang, Di-Ying; Bechly, Günter; Nel, Patricia; Engel, Michael S; Prokop, Jakub; Azar, Dany; Cai, Chen-Yang; van de Kamp, Thomas; Staniczek, Arnold H; Garrouste, Romain; Krogmann, Lars; Dos Santos Rolo, Tomy; Baumbach, Tilo; Ohlhoff, Rainer; Shmakov, Alexey S; Bourgoin, Thierry; Nel, André

    2016-03-10

    With nearly 100,000 species, the Acercaria (lice, plant lices, thrips, bugs) including number of economically important species is one of the most successful insect lineages. However, its phylogeny and evolution of mouthparts among other issues remain debatable. Here new methods of preparation permitted the comprehensive anatomical description of insect inclusions from mid-Cretaceous Burmese amber in astonishing detail. These "missing links" fossils, attributed to a new order Permopsocida, provide crucial evidence for reconstructing the phylogenetic relationships in the Acercaria, supporting its monophyly, and questioning the position of Psocodea as sister group of holometabolans in the most recent phylogenomic study. Permopsocida resolves as sister group of Thripida + Hemiptera and represents an evolutionary link documenting the transition from chewing to piercing mouthparts in relation to suction feeding. Identification of gut contents as angiosperm pollen documents an ecological role of Permopsocida as early pollen feeders with relatively unspecialized mouthparts. This group existed for 185 million years, but has never been diverse and was superseded by new pollenivorous pollinators during the Cretaceous co-evolution of insects and flowers. The key innovation of suction feeding with piercing mouthparts is identified as main event that triggered the huge post-Carboniferous radiation of hemipterans, and facilitated the spreading of pathogenic vectors.

  15. General design and main problems of a gas-heavy-water power reactor contained in a pressure vessel; Conception generale et principaux problemes d'un reacteur de puissance eau lourde-gaz contenu dans un caisson resistant

    Energy Technology Data Exchange (ETDEWEB)

    Roche, R; Gaudez, J C [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    In the framework of research carried out on a CO{sub 2}-cooled power reactor moderated by heavy water, the so-called 'pressure vessel' solution involves the total integration of the core, of the primary circuit (exchanges and blowers) and of the fuel handling machine inside a single, strong, sealed vessel made of pre-stressed concrete. A vertical design has been chosen: the handling 'attic' is placed above the core, the exchanges being underneath. This solution makes it possible to standardize the type of reactor which is moderated by heavy-water or graphite and cooled by a downward stream of carbon dioxide gas; it has certain advantages and disadvantages with respect to the pressure tube solution and these are considered in detail in this report. Extrapolation presents in particular.problems due specifically to the heavy water (for example its cooling,its purification, the balancing of the pressures of the heavy water and of the gas, the assembling of the internal structures, the height of the attic, etc. (authors) [French] Dans le cadre des etudes d'un reacteur de puissance modere a l'eau lourde et refroidi-au gaz carbonique, la solution dite 'en caisson' consiste en une integration totale du coeur, du circuit primaire (echangeurs et soufflantes) et du dispositif de manutention du combustible a l'interieur d'un meme caisson etanche et resistant en beton precontraint. La disposition envisagee est verticale; le grenier de manutention est dispose au-dessus du coeur, les echangeurs en dessous. Cette solution, qui permet d'uniformiser les types de reacteurs moderes a l'eau lourde ou au graphite et refroidis par une circulation descendante de gaz carbonique presente, par rapport a la solution a tube de force, des avantages et des inconvenients qui sont analyses dans cette etude. L'extrapolation pose, en particulier, des problemes specifiques a l'eau lourde (tels que son refroidissement, son epuration, l'equilibrage des pression entre l'eau lourde et le gaz, le montage

  16. Negative Suction Drain Through a Mini Periareolar Incision for the Treatment of Lactational Breast Abscess Shortens Hospital Stay and Increases Breastfeeding Rates.

    Science.gov (United States)

    Wei, Jinli; Zhang, Jiaxin; Fu, Deyuan

    2016-06-01

    Although breast abscess is a serious uncommon complication of mastitis with high morbidity rate, there is a lack of high-quality randomized trial to demonstrate the best treatments. We reported a novel way of applying negative suction drain through a mini periareolar incision. We retrospectively analyzed and compared the clinical characteristics of 62 patients with lactational breast abscess in our department from August 2012 to April 2015. Thirty-two patients went through traditional incision and drainage (Group A) and 30 patients were placed on negative suction drain through mini periareolar incision (Group B). There is no significant difference between the two groups in terms of age, white blood cell (WBC) count, size of the abscess cavity, and positive rate of Staphylococcus aureus (SA) or methicillin-resistant Staphylococcus aureus (MRSA). Patients in Group B had a shorter hospitalized stay (p = 0.003) and had a higher rate of continuation of breastfeeding (p breast abscess and maintaining breastfeeding.

  17. Subsurface storage of commercial spent nuclear fuel

    International Nuclear Information System (INIS)

    Richards, L.M.; Szulinski, M.J.

    1979-01-01

    The Atlantic Richfield Company has developed the concept of storing spent fuel in dry caissons. Cooling is passive; safety and safeguard features appear promising. The capacity of a caisson to dissipate heat depends on site-specific soil characteristics and on the diameter of the caisson. It is estimated that approx. 2 kW can be dissipated in the length of one fuel element. Fuel elements can be stacked with little effect on temperature. A spacing of approx. 7.5 m (25 ft) between caissons appears rasonable. Business planning indicates a cost of approx. 0.2 mill/kWh for a 15-yr storage period. 12 figures, 4 tables

  18. Observations on the flight pattern of some Phlaeothripidae (Thysanoptera species by using suction trap in Hungary

    Directory of Open Access Journals (Sweden)

    Orosz Szilvia

    2016-12-01

    Full Text Available In this study, the seasonal flight activity of the Phlaeothripidae (Thysanoptera species was studied by using suction trap, in South-East Hungary, in the years 2000 and 2004 from April to October. The flight period of two dominant species, namely Haplothrips angusticornis Priesner and Haplothrips aculeatus Fabricius (Thysanoptera: Phlaeothripidae, was observed in high number in Europe. Also, it was the first record of mass flight observation of H. angusticornis. In addition, the effect of meteorological factors, such as temperature, sunshine duration, relative humidity, air pressure, and their influences, were evaluated.

  19. On flexibility

    OpenAIRE

    Weiss, Christoph R.; Briglauer, Wolfgang

    2000-01-01

    By building on theoretical work by Mills and Schumann (1985) and Ungern-Sternberg (1990) this paper provides evidence on the determinants of two dimensions of flexibility, the flexibility in adjusting aggregate output over time (tactical flexibility) as well as the ability to switch quickly between products (operational flexibility). Econometric analysis of a sample of 40.000 farms in Upper-Austria for the period 1980 to 1990 suggests that larger full-time farms operated by younger, better ed...

  20. Balance and flexibility.

    Science.gov (United States)

    2003-12-01

    The 'work-life balance' and flexible working are currently key buzz terms in the NHS. Those looking for more information on these topics should visit Flexibility at www.flexibility.co.uk for a host of resources designed to support new ways of working, including information on flexible workers and flexible rostering, the legal balancing act for work-life balance and home working.

  1. Modification of Flow Structure Over a Van Model By Suction Flow Control to Reduce Aerodynamics Drag

    Directory of Open Access Journals (Sweden)

    Harinaldi Harinaldi

    2012-05-01

    Full Text Available Automobile aerodynamic studies are typically undertaken to improve safety and increase fuel efficiency as well as to  find new innovation in automobile technology to deal with the problem of energy crisis and global warming. Some car companies have the objective to develop control solutions that enable to reduce the aerodynamic drag of vehicle and  significant modification progress is still possible by reducing the mass, rolling friction or aerodynamic drag. Some flow  control method provides the possibility to modify the flow separation to reduce the development of the swirling structures around the vehicle. In this study, a family van is modeled with a modified form of Ahmed's body by changing the orientation of the flow from its original form (modified/reversed Ahmed body. This model is equipped with a suction on the rear side to comprehensively examine the pressure field modifications that occur. The investigation combines computational and experimental work. Computational approach used  a commercial software with standard k-epsilon flow turbulence model, and the objectives was  to determine the characteristics of the flow field and aerodynamic drag reduction that occurred in the test model. Experimental approach used load cell in order to validate the aerodynamic drag reduction obtained by computational approach. The results show that the application of a suction in the rear part of the van model give the effect of reducing the wake and the vortex formation. Futhermore, aerodynamic drag reduction close to 13.86% for the computational approach and 16.32% for the experimental have been obtained.

  2. Portable Filtered Air Suction System for Released Radioactive Gases Prevention under a Severe Accident of NPPs

    International Nuclear Information System (INIS)

    Gu, Beom W.; Choi, Su Y.; Rim, Chun T.

    2013-01-01

    In this paper, the portable filtered air suction system (PoFASS) for released radioactive gases prevention under a severe accident of NPP is proposed. This technology can prevent the release of the radioactive gases to the atmosphere and it can be more economical than FVCS because PoFASS can cover many NPPs with its high mobility. The conceptual design of PoFASS, which has the highest cost effectiveness and robustness to the environment condition such as wind velocity and precipitation, is suggested and the related previous research is introduced in this paper. The portable filtered air suction system (PoFASS) for released radioactive gases prevention can play a key role to mitigate the severe accident of NPP with its high cost effectiveness and robustness to the environment conditions. As further works, the detail design of PoFASS to fabricate a prototype for a demonstration will be proceeded. When released radioactive gases from the broken containment building in the severe accident of nuclear power plants (NPPs) such as the Chernobyl and Fukushima accidents occur, there are no ways to prevent the released radioactive gases spreading in the air. In order to solve this problem, several European NPPs have adopted the filtered vented containment system (FVCS), which can avoid the containment failure through a pressure relief capability to protect the containment building against overpressure. However, the installation cost of FVCS for a NPP is more than $10 million and this system has not been widely welcomed by NPP operating companies due to its high cost

  3. Office flexible cystoscopy.

    Science.gov (United States)

    Kavoussi, L R; Clayman, R V

    1988-11-01

    Since the development of the first purpose-built flexible cystoscope in 1984, flexible cystoscopy has become an accepted diagnostic and therapeutic modality. Indeed, it is estimated that more than 10 per cent of practicing urologists are already familiar with this technology. The flexible cystoscope has markedly extended the urologist's ability to examine the bladder, and it has become a valuable adjunct to the rigid cystoscope. Although the operation of this instrument is vastly different from that of its rigid counterpart, with practice, the technique can be learned. After experience is obtained with diagnostic flexible cystoscopy, the urologist will likely prefer this new instrument for bladder inspection, as it provides for a more thorough yet less morbid and less expensive examination. In the future, the development of improved and smaller instrumentation will further extend the therapeutic indications for flexible cystoscopy. Indeed, advances in laser technology are already providing the urologist with 300- to 600-micron (0.9 to 1.8F) flexible probes capable of incision (KTP laser), fulguration (Nd:YAG laser), and stone disintegration (tunable dye laser). Lastly, the skills obtained in using the flexible cystoscope are all readily applicable to the development of dexterity with the already available flexible nephroscope and the more recently developed flexible ureteroscope.

  4. Remora fish suction pad attachment is enhanced by spinule friction.

    Science.gov (United States)

    Beckert, Michael; Flammang, Brooke E; Nadler, Jason H

    2015-11-01

    The remora fishes are capable of adhering to a wide variety of natural and artificial marine substrates using a dorsal suction pad. The pad is made of serial parallel pectinated lamellae, which are homologous to the dorsal fin elements of other fishes. Small tooth-like projections of mineralized tissue from the dorsal pad lamella, known as spinules, are thought to increase the remora's resistance to slippage and thereby enhance friction to maintain attachment to a moving host. In this work, the geometry of the spinules and host topology as determined by micro-computed tomography and confocal microscope data, respectively, are combined in a friction model to estimate the spinule contribution to shear resistance. Model results are validated with natural and artificially created spinules and compared with previous remora pull-off experiments. It was found that spinule geometry plays an essential role in friction enhancement, especially at short spatial wavelengths in the host surface, and that spinule tip geometry is not correlated with lamellar position. Furthermore, comparisons with pull-off experiments suggest that spinules are primarily responsible for friction enhancement on rough host topologies such as shark skin. © 2015. Published by The Company of Biologists Ltd.

  5. Flexible structured high-frequency film bulk acoustic resonator for flexible wireless electronics

    International Nuclear Information System (INIS)

    Zhou, Changjian; Shu, Yi; Yang, Yi; Ren, Tian-Ling; Jin, Hao; Dong, Shu-Rong; Chan, Mansun

    2015-01-01

    Flexible electronics have inspired many novel and very important applications in recent years and various flexible electronic devices such as diodes, transistors, circuits, sensors, and radiofrequency (RF) passive devices including antennas and inductors have been reported. However, the lack of a high-performance RF resonator is one of the key bottlenecks to implement flexible wireless electronics. In this study, for the first time, a novel ultra-flexible structured film bulk acoustic resonator (FBAR) is proposed. The flexible FBAR is fabricated on a flexible polyimide substrate using piezoelectric thin film aluminum nitride (AlN) for acoustic wave excitation. Both the shear wave and longitudinal wave can be excited under the surface interdigital electrodes configuration we proposed. In the case of the thickness extension mode, a flexible resonator with a working frequency as high as of 5.2325 GHz has been realized. The resonators stay fully functional under bending status and after repeated bending and re-flattening operations. This flexible high-frequency resonator will serve as a key building block for the future flexible wireless electronics, greatly expanding the application scope of flexible electronics. (paper)

  6. Effects of mass transfer on MHD flow of casson fluid with chemical reaction and suction

    Directory of Open Access Journals (Sweden)

    S. A. Shehzad

    2013-03-01

    Full Text Available Effect of mass transfer in the magnetohydrodynamic flow of a Casson fluid over a porous stretching sheet is addressed in the presence of a chemical reaction. A series solution for the resulting nonlinear flow is computed. The skin friction coefficient and local Sherwood number are analyzed through numerical values for various parameters of interest. The velocity and concentration fields are illustrated for several pertinent flow parameters. We observed that the Casson parameter and Hartman number have similar effects on the velocity in a qualitative sense. We further analyzed that the concentration profile decreases rapidly in comparison to the fluid velocity when we increased the values of the suction parameter.

  7. Flexibility@Work 2013: yearly report on flexible labor and employment

    NARCIS (Netherlands)

    Berkhout, E.; Heyma, A.; Prins, J.

    2013-01-01

    There is no clear evidence that the strong growth in the share of flexible labor relations between 2002 and 2007 points at a worldwide trend towards a larger share of flexible labor at the expense of traditional open-ended labor contracts. The growth in flexible labor varies too much between

  8. Instability and Transition of Flow at, and Near, an Attachment-line - Including Control by Surface Suction

    Science.gov (United States)

    Smith, A.

    1996-01-01

    Advances in aviation during and following the Second World War led to an enormous improvement in the performance of aircraft. The push for enhanced efficiency brought cruise speeds into the transonic range, where the associated drag rise due to the appearance of shock-waves became a limiting factor. Wing sweep was adopted to delay the onset of this drag rise, but with this development came several new and unforeseen problems. Preliminary theoretical work assumed that the boundary layer transition characteristics of a swept wing would be subject to the independence principle, so the chordwise transition position could be predicted from two-dimensional work Gas turbine development has now reached a point where additional increases in efficiency are both difficult and expensive to achieve. Consequently, aircraft manufacturers are looking elsewhere for ways to reduce Direct Operating Costs (DOC's) or increase military performance. The attention of industry is currently focusing on Hybrid Laminar Flow Control (HLFC) as a possible method of reducing DOC's for civil aircraft. Following this study and discussions with NASA Langley and Boeing a different series of questions have been addressed in the present work. There are five areas of interest: Relaminarisation of the attachment-line boundary layer when the value of R exceeds 600. The effects of large suction levels on transition in the attachment-line boundary layer (ie critical oversuction). The transition characteristics of a relaminarised attachment-line flow which encounters a non-porous surface. The effect of attachment-line suction on the spanwise propagation of gross disturbances emanating from the wing-fuselage junction. The attachment-line transition caused by surface blowing.

  9. Field lysimeter facility for evaluating the performance of commercial solidified low-level waste

    International Nuclear Information System (INIS)

    Walter, M.B.; Graham, M.J.; Gee, G.W.

    1984-11-01

    Analyzing the potential migration of radionuclides from sites containing solid low-level wastes requires knowledge of contaminant concentrations in the soil solution surrounding the waste. This soil solution concentration is generally referred to as the source term and is determined by such factors as the concentration of radionuclides in the solid waste, the rate of leachate formation, the concentration of dissolved species in the leachate, any solubility reactions occurring when the leachate contacts the soil, and the rate of water flow in the soil surrounding the waste. A field lysimeter facility established at the Hanford site is being used to determine typical source terms in arid climates for commercial low-level wastes solidifed with cement, Dow polymer (vinyl ester-styrene), and bitumen. The field lysimeter facility consists of 10, 3-m-deep by 1.8-m-dia closed-bottom lysimeters situated around a 4-m-deep by 4-m-dia central instrument caisson. Commercial cement and Dow polymer waste samples were removed from 210-L drums and placed in 8 of the lysimeters. Two bitumen samples are planned to be emplaced in the facility's remaining 2 lysimeters during 1984. The central caisson provides access to the instrumentation in the individual lysimeters and allows selective sampling of the soil and waste. Suction candles (ceramic cups) placed around the waste forms will be used to periodically collect soil-water samples for chemical analysis. Meteorological data, soil moisture content, and soil temperature are automatically monitored at the facility. Characterization of the soils and waste forms have been partially completed. These data consist of moisture release characteristics, particle-size distribution, and distributions and concentrations of radionuclides in the waste forms. 11 references, 12 figures, 5 tables

  10. Long-term clinical evaluation of a 800-nm long-pulsed diode laser with a large spot size and vacuum-assisted suction for hair removal.

    Science.gov (United States)

    Ibrahimi, Omar A; Kilmer, Suzanne L

    2012-06-01

    The long-pulsed diode (800-810-nm) laser is one of the most commonly used and effective lasers for hair removal. Limitations of currently available devices include a small treatment spot size, treatment-associated pain, and the need for skin cooling. To evaluate the long-term hair reduction capabilities of a long-pulsed diode laser with a large spot size and vacuum assisted suction. Thirty-five subjects were enrolled in a prospective, self-controlled, single-center study of axillary hair removal. The study consisted of three treatments using a long-pulsed diode laser with a large spot size and vacuum-assisted suction at 4- to 6-week intervals with follow-up visits 6 and 15 months after the last treatment. Hair clearance was quantified using macro hair-count photographs taken at baseline and at 6- and 15-month follow-up visits. Changes in hair thickness and color, levels of treatment-associated pain, and adverse events were additional study endpoints. There was statistically significant hair clearance at the 6 (54%) and 15-month (42%) follow-up visits. Remaining hairs were thinner and lighter at the 15-month follow-up visit, and the majority of subjects reported feeling up to mild to moderate pain during treatment without the use of pretreatment anesthesia or skin cooling. A long-pulsed diode laser with a large spot size and vacuum-assisted suction is safe and effective for long-term hair removal. This is the largest prospective study to evaluate long-term hair removal and the first to quantify decreases in hair thickness and darkness with treatment. © 2012 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.

  11. ISSN 2073 ISSN 2073-9990 East Cent. Afr. J. surg. (Online) 9990 ...

    African Journals Online (AJOL)

    Prof Kakande

    The hematoma was evacuated and a drain inserted. On the ... measures used to prevent this complication. Rigid and flexible ... suction through endotracheal tubes in patients who cannot withstand bronchoscopy. However the use of.

  12. Hydraulic Performance of Seawave Slot-Cone Generator Pilot Plant at Kvitsøy (Norway)

    DEFF Research Database (Denmark)

    Margheritini, Lucia; Vicinanza, D.; Kofoed, Jens Peter

    This paper presents results on wave overtopping and loading on an innovative caisson breakwater for electricity production.......This paper presents results on wave overtopping and loading on an innovative caisson breakwater for electricity production....

  13. A biorobotic model of the suction-feeding system in largemouth bass: the roles of motor program speed and hyoid kinematics

    OpenAIRE

    Kenaley, Christopher P.; Lauder, George V.

    2016-01-01

    The vast majority of ray-finned fishes capture prey through suction feeding. The basis of this behavior is the generation of subambient pressure through rapid expansion of a highly kinetic skull. Over the last four decades, results from in vivo experiments have elucidated the general relationships between morphological parameters and subambient pressure generation. Until now, however, researchers have been unable to tease apart the discrete contributions of, and complex relationships among, t...

  14. Effect of boron addition on the magnetic properties of the Fe-Nd-Al alloys prepared by suction casting

    International Nuclear Information System (INIS)

    Bai, Q.; Xu, H.; Tan, X.H.; Zhang, S.Y.

    2007-01-01

    The microstructure and magnetic properties of the Fe-Nd-Al alloys prepared by suction casting with boron addition have been investigated. The increasing boron content in the Fe-Nd-Al alloys significantly increases the intrinsic coercivity ( i H c ) and decreases the proportion of the amorphous phase. The magnetization at the maximum applied field (σ ' s ) of the Fe-Nd-Al-B alloys decreases, while the coercivity increases markedly after annealing. The high intrinsic coercivity is due to the presence of the Nd 2 Fe 14 B phase

  15. Summary of Fy 97 Work on Multipore Suction Techniques

    National Research Council Canada - National Science Library

    Mittleman, John

    1997-01-01

    .... The proposed embodiment uses a urethane composite material basically formed as a honeycomb with flexible yet somewhat stiff walls with each pore filled with an extremely soft material (see Figure 1...

  16. Dynamic Model of a Rotating Flexible Arm-Flexible Root Mechanism Driven by a Shaft Flexible in Torsion

    Directory of Open Access Journals (Sweden)

    S.Z. Ismail

    2006-01-01

    Full Text Available This paper presents a dynamic model of a rotating flexible beam carrying a payload at its tip. The model accounts for the driving shaft and the arm root flexibilities. The finite element method and the Lagrangian dynamics are used in deriving the equations of motion with the small deformation theory assumptions and the Euler-Bernoulli beam theory. The obtained model is a nonlinear-coupled system of differential equations. The model is simulated for different combinations of shaft and root flexibilities and arm properties. The simulation results showed that the root flexibility is an important factor that should be considered in association with the arm and shaft flexibilities, as its dynamics influence the motor motion. Moreover, the effect of system non-linearity on the dynamic behavior is investigated by simulating the equivalent linearized system and it was found to be an important factor that should be considered, particularly when designing a control strategy for practical implementation.

  17. General design and main problems of a gas-heavy-water power reactor contained in a pressure vessel; Conception generale et principaux problemes d'un reacteur de puissance eau lourde-gaz contenu dans un caisson resistant

    Energy Technology Data Exchange (ETDEWEB)

    Roche, R.; Gaudez, J.C. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    In the framework of research carried out on a CO{sub 2}-cooled power reactor moderated by heavy water, the so-called 'pressure vessel' solution involves the total integration of the core, of the primary circuit (exchanges and blowers) and of the fuel handling machine inside a single, strong, sealed vessel made of pre-stressed concrete. A vertical design has been chosen: the handling 'attic' is placed above the core, the exchanges being underneath. This solution makes it possible to standardize the type of reactor which is moderated by heavy-water or graphite and cooled by a downward stream of carbon dioxide gas; it has certain advantages and disadvantages with respect to the pressure tube solution and these are considered in detail in this report. Extrapolation presents in particular.problems due specifically to the heavy water (for example its cooling,its purification, the balancing of the pressures of the heavy water and of the gas, the assembling of the internal structures, the height of the attic, etc. (authors) [French] Dans le cadre des etudes d'un reacteur de puissance modere a l'eau lourde et refroidi-au gaz carbonique, la solution dite 'en caisson' consiste en une integration totale du coeur, du circuit primaire (echangeurs et soufflantes) et du dispositif de manutention du combustible a l'interieur d'un meme caisson etanche et resistant en beton precontraint. La disposition envisagee est verticale; le grenier de manutention est dispose au-dessus du coeur, les echangeurs en dessous. Cette solution, qui permet d'uniformiser les types de reacteurs moderes a l'eau lourde ou au graphite et refroidis par une circulation descendante de gaz carbonique presente, par rapport a la solution a tube de force, des avantages et des inconvenients qui sont analyses dans cette etude. L'extrapolation pose, en particulier, des problemes specifiques a l'eau lourde (tels que son refroidissement, son epuration

  18. Global Sourcing Flexibility

    DEFF Research Database (Denmark)

    Ørberg Jensen, Peter D.; Petersen, Bent

    2013-01-01

    the higher costs (but decreased risk for value chain disruption) embedded in a more flexible global sourcing model that allows the firm to replicate and/or relocate activities across multiple locations. We develop a model and propositions on facilitating and constraining conditions of global sourcing...... sourcing flexibility. Here we draw on prior research in the fields of organizational flexibility, international business and global sourcing as well as case examples and secondary studies. In the second part of the paper, we discuss the implications of global sourcing flexibility for firm strategy...... and operations against the backdrop of the theory-based definition of the construct. We discuss in particular the importance of global sourcing flexibility for operational performance stability, and the trade-off between specialization benefits, emerging from location and service provider specialization, versus...

  19. In patients with extensive subcutaneous emphysema, which technique achieves maximal clinical resolution: infraclavicular incisions, subcutaneous drain insertion or suction on in situ chest drain?

    Science.gov (United States)

    Johnson, Charles H N; Lang, Sommer A; Bilal, Haris; Rammohan, Kandadai S

    2014-06-01

    A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was: 'In patients with extensive subcutaneous emphysema, which technique achieves maximal clinical resolution: infraclavicular incisions, subcutaneous drain insertion or suction on in situ chest drain?'. Altogether more than 200 papers were found using the reported search, of which 14 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. Subcutaneous emphysema is usually a benign, self-limiting condition only requiring conservative management. Interventions are useful in the context of severe patient discomfort, respiratory distress or persistent air leak. In the absence of any comparative study, it is not possible to choose definitively between infraclavicular incisions, drain insertion and increasing suction on an in situ drain as the best method for managing severe subcutaneous emphysema. All the three techniques described have been shown to provide effective relief. Increasing suction on a chest tube already in situ provided rapid relief in patients developing SE following pulmonary resection. A retrospective study showed resolution in 66%, increasing to 98% in those who underwent video-assisted thoracic surgery with identification and closure of the leak. Insertion of a drain into the subcutaneous tissue also provided rapid sustained relief. Several studies aided drainage by using regular compressive massage. Infraclavicular incisions were also shown to provide rapid relief, but were noted to be more invasive and carried the potential for cosmetic defect. No major complications were illustrated. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  20. Field test facility for monitoring water/radionuclide transport through partially saturated geologic media: design, construction, and preliminary description. Appendix I. Engineering drawings

    International Nuclear Information System (INIS)

    Phillips, S.J.; Campbell, A.C.; Campbell, M.D.; Gee, G.W.; Hoober, H.H.; Schwarzmiller, K.O.

    1979-11-01

    The engineering plans for a test facility to monitor radionuclide transport in water through partially saturated geological media are included. Drawings for the experimental set-up excavation plan and details, lysimeter, pad, access caisson, and caisson details are presented

  1. Conflicting flexibility

    NARCIS (Netherlands)

    De Jong, P.; Schaap, A.

    2011-01-01

    New buildings are designed for first users. For a sustainable approach there are many advantages in designing in flexibility and adjustability in order to enable and facilitate the other sequential users. For the first investor this flexibility is translated into improved exit values due to

  2. Suckermouth armored catfish resolve the paradox of simultaneous respiration and suction attachment: a kinematic study of Pterygoplichthys disjunctivus.

    Science.gov (United States)

    Geerinckx, Tom; Herrel, Anthony; Adriaens, Dominique

    2011-03-01

    Suckermouth armored catfishes (Loricariidae) use their suckermouth for inspiration, feeding, and attachment to substrates. The sucker consists of a pre-valvular cavity, formed by a modified lip disc, and is separated from the larger post-valvular buccal cavity by a muscular oral valve. The combination of respiration and suction attachment seems paradoxal, as a properly functioning suction device would need a sucker without leakage (yet inspiration must occur via the sucker), and continuous subambient pressure in the sucker cavity (even during expiratory mouth floor elevation). In the loricariid Pterygoplichthys disjunctivus, the anatomy of the suckermouth structures was examined, and a kinematic analysis was performed to acquire insights into how respiration and attachment are combined. High-speed external and X-ray recordings show that suckermouth attachment influences respiratory parameters such as decreasing excursion amplitudes of mouth floor elements, and the way water enters the mouth via furrows in the lip disc. Respiration, however, continues during attachment and is not blocked. Our data show that the muscular oral valve actively separates the post-valvular buccal cavity from the pre-valvular sucker cavity. Volume changes of this pre-valvular cavity are opposite to those of the post-valvular cavity and assure sucker function even during expiration. These volume changes are caused by movements of the lower lip, the lower jaws, and the oral valve. The lateral inflow furrow openings, controlled by the maxillary barbels, can occur unilaterally. Morphological and kinematic data also show that the opercle is anatomically and functionally decoupled from the gill opening. Copyright © 2010 Wiley-Liss, Inc., A Wiley Company.

  3. Inter-vertebral flexibility of the ostrich neck: implications for estimating sauropod neck flexibility.

    Science.gov (United States)

    Cobley, Matthew J; Rayfield, Emily J; Barrett, Paul M

    2013-01-01

    The flexibility and posture of the neck in sauropod dinosaurs has long been contentious. Improved constraints on sauropod neck function will have major implications for what we know of their foraging strategies, ecology and overall biology. Several hypotheses have been proposed, based primarily on osteological data, suggesting different degrees of neck flexibility. This study attempts to assess the effects of reconstructed soft tissues on sauropod neck flexibility through systematic removal of muscle groups and measures of flexibility of the neck in a living analogue, the ostrich (Struthio camelus). The possible effect of cartilage on flexibility is also examined, as this was previously overlooked in osteological estimates of sauropod neck function. These comparisons show that soft tissues are likely to have limited the flexibility of the neck beyond the limits suggested by osteology alone. In addition, the inferred presence of cartilage, and varying the inter-vertebral spacing within the synovial capsule, also affect neck flexibility. One hypothesis proposed that flexibility is constrained by requiring a minimum overlap between successive zygapophyses equivalent to 50% of zygapophyseal articular surface length (ONP50). This assumption is tested by comparing the maximum flexibility of the articulated cervical column in ONP50 and the flexibility of the complete neck with all tissues intact. It is found that this model does not adequately convey the pattern of flexibility in the ostrich neck, suggesting that the ONP50 model may not be useful in determining neck function if considered in isolation from myological and other soft tissue data.

  4. Inter-vertebral flexibility of the ostrich neck: implications for estimating sauropod neck flexibility.

    Directory of Open Access Journals (Sweden)

    Matthew J Cobley

    Full Text Available The flexibility and posture of the neck in sauropod dinosaurs has long been contentious. Improved constraints on sauropod neck function will have major implications for what we know of their foraging strategies, ecology and overall biology. Several hypotheses have been proposed, based primarily on osteological data, suggesting different degrees of neck flexibility. This study attempts to assess the effects of reconstructed soft tissues on sauropod neck flexibility through systematic removal of muscle groups and measures of flexibility of the neck in a living analogue, the ostrich (Struthio camelus. The possible effect of cartilage on flexibility is also examined, as this was previously overlooked in osteological estimates of sauropod neck function. These comparisons show that soft tissues are likely to have limited the flexibility of the neck beyond the limits suggested by osteology alone. In addition, the inferred presence of cartilage, and varying the inter-vertebral spacing within the synovial capsule, also affect neck flexibility. One hypothesis proposed that flexibility is constrained by requiring a minimum overlap between successive zygapophyses equivalent to 50% of zygapophyseal articular surface length (ONP50. This assumption is tested by comparing the maximum flexibility of the articulated cervical column in ONP50 and the flexibility of the complete neck with all tissues intact. It is found that this model does not adequately convey the pattern of flexibility in the ostrich neck, suggesting that the ONP50 model may not be useful in determining neck function if considered in isolation from myological and other soft tissue data.

  5. Thermodynamic analysis of a refrigeration cycle using regenerative heat exchanger - suction/liquid line

    Energy Technology Data Exchange (ETDEWEB)

    Tebchirani, Tarik Linhares; Matos, Rudmar Serafim [Pos graduate Programme in Mechanical Engineering (PGMEC), Universidade Federal do Parana, Curitiba, PR (Brazil)], e-mails: tarik@utfpr.edu.br, rudmar@demec.ufpr.br

    2010-07-01

    This paper presents results from thermodynamic comparison of a conventional compression cycle and a steam cycle that uses a heat exchanger countercurrent (liquid line/suction line) in an air conditioning system split. The main objective is to study the relationship between the COP and the mass variation of refrigerant to the effectiveness of the heat exchanger. The papers presented in the literature discuss the matter in a theoretical way, are summarized in tables of rare loss statements without specification of methods. The methodology of work is based on testing of an air conditioner operating conventionally and also with the heat exchanger for the determination of values and parameters of interest. The tests were performed in a thermal chamber with temperature controlled and equipped with a data acquisition system for reading and storage results. The refrigerant was R22. Besides making possible an assessment of the feasibility of cost-benefit thermodynamics, it is suggested a different method for installing the equipment type split. (author)

  6. Non-Destructive Testing in Reactor Pressure-Vessel Fabrication; Essais non Destructifs dans la Fabrication des Caissons Etanches de Reacteurs; Nedestruktivnoe ispytanie pri izgotovlenii reaktornykh bakov vysokogo davleniya; Ensayo no Destructivo Durante la Fabricacion de Recipientes de Presion para Reactores

    Energy Technology Data Exchange (ETDEWEB)

    McGonnagle, W. J. [Fluids Dynamics Research, Iit Research Institute, Chicago, IL (United States)

    1965-09-15

    of the pressure vessel are discussed. (author) [French] Le memoire a pour objet d'exposer les grandes lignes d'un programme de controle de la qualite dans la fabrication d'un caisson etanche de reacteur qui satisfera a toutes les specifications du point de vue nucleaire et de la securite, et de mettre en evidence le role et l'importance des essais non destructifs dans ce programme. Les defauts constates dans les materiaux, les elements et leur assemblage montrent que les methodes actuelles de fabrication ne permettent pas en elles-memes d'assurer le maintien de la qualite des elements critiques. 11 se produit des pailles et des heterogeneites memes lorsque l'on utilise les meilleurs procedes de fabrication et que l'on applique des methodes et techniques dument controlees. C'est pourquoi, afin d'obtenir la qualite requise pour un caisson de reacteur, il faut executer un programme approprie et coherent d'essais non destructifs. Les principales methodes d'essais non destructifs appliquees par les fabricants de caissons de reacteurs sont les suivantes: inspection visuelle, radiographie par les rayons X ou gamma, ultrasons, particules magnetiques et penetration de liquides. Le programme d'essais non destructifs comporte le controle des materiau', du forgeage, du moulage, du gainage et des soudures. L'auteur etudie les problemes particuliers que posent les essais non destructifs des caissons etanches. Il decrit et discute les techniques speciales propres aux essais non destructifs des caissons et de leurs elements. Le memoire donne un apercu des reglements et specifications applicables, notamment du reglement de fabrication des bouilleurs et caissons etanches publie par la Societe americaine des ingenieurs mecaniciens. L'auteur etudie la mesure dans laquelle les essais non destructifs peuvent contribuer a repondre aux specifications imposees par les institutions de normalisation, ainsi que la mesure dans laquelle les normes admises pour ces essais sont appropriees et

  7. Validity of simplified Analysis of Stability of Caison Breakwaters on Rubble Foundation Exposed to Impulsive Loads

    DEFF Research Database (Denmark)

    Andersen, Lars; Burcharth, Hans F.; Andersen, Thomas Lykke

    2011-01-01

    Wave slamming on vertical breakwaters cause a sudden, impulsive load that may cause a caisson to slide on its foundation. Alternatively, geotechnical failure may occur in the subsoil. This paper investigates whether simple analytical solutions, accounting only for the sliding along the caisson...

  8. Flexible Carbon Aerogels

    Directory of Open Access Journals (Sweden)

    Marina Schwan

    2016-09-01

    Full Text Available Carbon aerogels are highly porous materials with a large inner surface area. Due to their high electrical conductivity they are excellent electrode materials in supercapacitors. Their brittleness, however, imposes certain limitations in terms of applicability. In that context, novel carbon aerogels with varying degree of flexibility have been developed. These highly porous, light aerogels are characterized by a high surface area and possess pore structures in the micrometer range, allowing for a reversible deformation of the aerogel network. A high ratio of pore size to particle size was found to be crucial for high flexibility. For dynamic microstructural analysis, compression tests were performed in-situ within a scanning electron microscope allowing us to directly visualize the microstructural flexibility of an aerogel. The flexible carbon aerogels were found to withstand between 15% and 30% of uniaxial compression in a reversible fashion. These findings might stimulate further research and new application fields directed towards flexible supercapacitors and batteries.

  9. Reversibly Bistable Flexible Electronics

    KAUST Repository

    Alfaraj, Nasir

    2015-05-01

    Introducing the notion of transformational silicon electronics has paved the way for integrating various applications with silicon-based, modern, high-performance electronic circuits that are mechanically flexible and optically semitransparent. While maintaining large-scale production and prototyping rapidity, this flexible and translucent scheme demonstrates the potential to transform conventionally stiff electronic devices into thin and foldable ones without compromising long-term performance and reliability. In this work, we report on the fabrication and characterization of reversibly bistable flexible electronic switches that utilize flexible n-channel metal-oxide-semiconductor field-effect transistors. The transistors are fabricated initially on rigid (100) silicon substrates before they are peeled off. They can be used to control flexible batches of light-emitting diodes, demonstrating both the relative ease of scaling at minimum cost and maximum reliability and the feasibility of integration. The peeled-off silicon fabric is about 25 µm thick. The fabricated devices are transferred to a reversibly bistable flexible platform through which, for example, a flexible smartphone can be wrapped around a user’s wrist and can also be set back to its original mechanical position. Buckling and cyclic bending of such host platforms brings a completely new dimension to the development of flexible electronics, especially rollable displays.

  10. Experiment data of 200% recirculation pump discharge line break integral test run 961 with HPCS failure at ROSA-III and comparison with results of suction line break tests

    International Nuclear Information System (INIS)

    Suzuki, Mitsuhiro; Tasaka, Kanji; Nakamura, Hideo; Anoda, Yoshinari; Kumamaru, Hiroshige; Murata, Hideo; Yonomoto, Taisuke; Shiba, Masayoshi

    1984-03-01

    This report presents the experimental data of RUN 961, a 200% double-ended break test at the recirculation pump discharge line in the ROSA-III test facility. The ROSA-III test facility is a volumetrically scaled (1/424) system of the BWR/6. The facility has the electrically heated core, the break simulator and the scaled ECCS (Emergency Core Cooling System). The MSIV (Main Steam Isolation Valve) closure and the ECCS actuation were tripped by the liquid level in the upper downcomer. The PCT (Peak Cladding Temperature) was 894 K, which was 107 K higher than a 200% pump suction line break test (RUN 926) due to the smaller depressurization rate. The effect of break location on transient LOCA phenomena was clarified by comparing the discharge and suction break tests. The whole core was quenched 71 s after LPCI actuation and the effectiveness of ECCS has been confirmed. (author)

  11. Flexible MEMS: A novel technology to fabricate flexible sensors and electronics

    Science.gov (United States)

    Tu, Hongen

    This dissertation presents the design and fabrication techniques used to fabricate flexible MEMS (Micro Electro Mechanical Systems) devices. MEMS devices and CMOS(Complementary Metal-Oxide-Semiconductor) circuits are traditionally fabricated on rigid substrates with inorganic semiconductor materials such as Silicon. However, it is highly desirable that functional elements like sensors, actuators or micro fluidic components to be fabricated on flexible substrates for a wide variety of applications. Due to the fact that flexible substrate is temperature sensitive, typically only low temperature materials, such as polymers, metals, and organic semiconductor materials, can be directly fabricated on flexible substrates. A novel technology based on XeF2(xenon difluoride) isotropic silicon etching and parylene conformal coating, which is able to monolithically incorporate high temperature materials and fluidic channels, was developed at Wayne State University. The technology was first implemented in the development of out-of-plane parylene microneedle arrays that can be individually addressed by integrated flexible micro-channels. These devices enable the delivery of chemicals with controlled temporal and spatial patterns and allow us to study neurotransmitter-based retinal prosthesis. The technology was further explored by adopting the conventional SOI-CMOS processes. High performance and high density CMOS circuits can be first fabricated on SOI wafers, and then be integrated into flexible substrates. Flexible p-channel MOSFETs (Metal-Oxide-Semiconductor Field-Effect-Transistors) were successfully integrated and tested. Integration of pressure sensors and flow sensors based on single crystal silicon has also been demonstrated. A novel smart yarn technology that enables the invisible integration of sensors and electronics into fabrics has been developed. The most significant advantage of this technology is its post-MEMS and post-CMOS compatibility. Various high

  12. Operational experience acquired in radioactive waste compaction

    International Nuclear Information System (INIS)

    Bauer, S.; Mohr, P.; Hempelmann, W.

    1993-01-01

    The low-level radioactive waste scrapping facility in the KfK decontamination division was commissioned in 1983. Non-combustible residues and removed system components of low activity, but which are to be handled and disposed of as radioactive waste are in drums, casks or containers delivered to the facility. The waste usually undergoes pretreatment in a crusher, with the volume being definitively reduced at a pressure of 690 bar in the high-pressure compactor. In 1990, the overhead-crane was refurbished for remote control handling in the scrapping caisson. The parts to undergo scrapping are unpacked in the material lock, and then go into the scrapping caisson. It is possible to use here various mechanical and thermal methods to dismantle the respective parts. But most of the parts to undergo scrapping are such as that it is possible to directly pretreat them in the crusher. The obtained scrap is loaded into 180-liter drums. Most of the machinery in the caisson is manually operated. The operating crew enters the caisson in fully ventilated protective overalls. The drums filled with the scrap then go to the high-pressure compactor in the caisson. The compacts are temporarily stored, until recalled depending on their height and filled into drums such as that optimal drum filling is guaranteed

  13. Flexible Carpooling: Exploratory Study

    OpenAIRE

    Dorinson, Diana; Gay, Deanna; Minett, Paul; Shaheen, Susan

    2009-01-01

    Energy consumption could be reduced if more people shared rides rather than driving alone yet carpooling represents a small proportion of all potential carpoolers. Prior research has found that many who might carpool were concerned about reduced flexibility with carpooling. If flexibility is one of the barriers how could carpooling be organized to be more flexible? In Northern Virginia a flexible system has evolved where there are 3,500 single-use carpools per day. In another example there ...

  14. Local Flexibility Market Design for Aggregators Providing Multiple Flexibility Services at Distribution Network Level

    Directory of Open Access Journals (Sweden)

    Pol Olivella-Rosell

    2018-04-01

    Full Text Available This paper presents a general description of local flexibility markets as a market-based management mechanism for aggregators. The high penetration of distributed energy resources introduces new flexibility services like prosumer or community self-balancing, congestion management and time-of-use optimization. This work is focused on the flexibility framework to enable multiple participants to compete for selling or buying flexibility. In this framework, the aggregator acts as a local market operator and supervises flexibility transactions of the local energy community. Local market participation is voluntary. Potential flexibility stakeholders are the distribution system operator, the balance responsible party and end-users themselves. Flexibility is sold by means of loads, generators, storage units and electric vehicles. Finally, this paper presents needed interactions between all local market stakeholders, the corresponding inputs and outputs of local market operation algorithms from participants and a case study to highlight the application of the local flexibility market in three scenarios. The local market framework could postpone grid upgrades, reduce energy costs and increase distribution grids’ hosting capacity.

  15. [Inspecting the cochlear scala tympanic with flexible and semi-flexible micro-endoscope].

    Science.gov (United States)

    Zhang, Daoxcing; Zhang, Yankun

    2006-02-01

    Flexible and semi-flexible micro-endoscopes were used in cochlear scala tympani inspection , to explore their application in inner ear examination. Fifteen profound hearing loss patients preparing for cochlear implant were included in this study. During the operation, micro-endoscopy was performed after opening the cochlear scala tympani. And 1 mm diameter semi-flexible micro-endoscope could go as deep as 9 mm into the cochlear scala tympani, while 0. 5 mm diameter flexible micro-endoscope could go as deep as 25 mm. The inspecting results were compared with video recording. Using 0.5 mm flexible micro-endoscope, we canould check cochlear scala tympani with depth range of 15-25 mm, but the video imaging was not clear enough to examine the microstructure in the cochlear. With 1 mm diameter semi-flexible micro-endoscope, we could reach 9 mm deep into the cochlear. During the examination, we found 3 cases with calcification deposit in osseous spiral lamina, l case with granulation tissue in the lateral wall of scala tympani, no abnormal findings in the other 11 cases. Inspecting the cochlear scala tympani with 0.5 mm flexible micro-endoscope, even though we can reach the second circuit of the cochlear, it is difficult to find the pathology in the cochlear because of the poor video imaging. With 1 mm semi-flexible micro-endoscope, we can identify the microstructure of the cochlear clearly and find the pathologic changes, but the inserting depth was limited to 9 mm with limitation to examine the whole cochlear.

  16. Development of Flexible Pneumatic Cylinder with Built-in Flexible Linear Encoder and Flexible Bending Sensor

    Science.gov (United States)

    Akagi, Tetsuya; Dohta, Shujiro; Matsushita, Hisashi; Fukuhara, Akimasa

    The purpose of this study is to develop a lightweight and intelligent soft actuator which can be safely attached to the human body. A novel flexible pneumatic cylinder that can be used even if it is deformed by external force had been proposed. The cylinder can realize both pushing and pulling motions even if the cylinder bends. In this paper, a flexible pneumatic cylinder with a built-in flexible linear encoder is proposed and tested. The encoder can detect the cylinder displacement even if the cylinder bends. In the next step, to realize an intelligent flexible cylinder, it is essential to recognize the angle of deflection of the cylinder to estimate the direction of the external force. Therefore, a flexible bending sensor that can measure the directional angle by attaching it to the end of the cylinder is also proposed and tested. The tested bending sensor also consists of four inexpensive photo-reflectors set on the circumferential surface to the cylinder tube every 90 degrees from the center of the tube. By measuring the distance between the photo reflector and the surface of the tube at each point, the bending directional angle of the cylinder can be obtained. A low cost measuring system using a micro-computer incorporating a programmed Up/Down counter to measure the displacement of the cylinder is also developed. As a result, it was confirmed that the measuring accuracy of the bending directional angle was good, less than 0.7 degrees as a standard deviation.

  17. High negative pressure subcutaneous suction drain for managing debilitating subcutaneous emphysema secondary to tube thoracostomy for an iatrogenic post computed tomography guided transthoracic needle biopsy pneumothorax: Case report and review of literature

    Directory of Open Access Journals (Sweden)

    Zeeshan Ahmed

    2016-01-01

    Conclusion: Debilitating subcutaneous emphysema which causes distress, anxiety, palpebral closure, dyspnoea or dysphagia requires intervention. High negative pressure subcutaneous suction drain provides immediate and sustained relief in extensive and debilitating SE.

  18. Efectos de la contención en hipoxia percutánea posterior a la aspiración endotraqueal en neonatos Effects of containment on percutaneous hipoxia after endotracheal suctioning in neonates

    Directory of Open Access Journals (Sweden)

    Bertha Cecilia Salazar González

    2007-03-01

    Full Text Available Objetivo: Verificar la efectividad de la contención en el tiempo de recuperación de la hipoxia percutánea de neonatos prematuros con Síndrome de Dificultad Respiratoria, posterior a la aspiración con y sin bolsa de oxígeno pre-aspiración. La contención es una técnica que limita los movimientos del neonato simulando el ambiente uterino y se propone como ayuda para inducir la relajación en los prematuros. Material y métodos: Se diseñó un estudio de mediciones repetidas con un grupo; cada neonato fue su propio control. Se estudiaron 30 neonatos nacidos entre la semana 26 y 36 de gestación en una Unidad de Cuidados Intensivos Neonatal de un Hospital de Seguridad Social de Monterrey, de agosto a diciembre de 2002. Se observaron cuatro procedimientos de aspiración endotraqueal: dos sin contención y dos con contención. Resultados: El peso al nacer de los neonatos osciló entre .790 y 3.275 Kg. De acuerdo con el expediente, 25 de ellos (83.30% presentaron Síndrome de Dificultad Respiratoria moderado. La prueba de análisis de varianza, F(3,87= 7.77, p Objective: The purpose was to verify the effectiveness of containment using pre-suction oxygen bag versus non pre-suction oxygen bag on recovery time of percutaneous hipoxia values after endotracheal suctioning of premature infants with respiratory distress syndrome. Containment is proposed as an aid to induce relaxation in premature babies; it is a technique that limits a neonate’s movements resembling the uterus environment. Material and methods: A crossover design with one group was used, each neonate serve as its own control. This study was conducted in 30 neonates who had been born between 26 and 36 weeks gestational age, in a Neonatal Intensive Care Unit of a Social Security’s Hospital in Monterrey. Each neonate was observed during four suction procedures: two without containment and two with containment. Results: The neonate’s weight ranged from .790 to 3.275Kg., according to

  19. Energy Flexibility in Retail Buildings

    DEFF Research Database (Denmark)

    Ma, Zheng; Billanes, Joy Dalmacio; Kjærgaard, Mikkel Baun

    2017-01-01

    Retail buildings has an important role for demand side energy flexibility because of their high energy consumption, variety of energy flexibility resources, and centralized control via building control systems. Energy flexibility requires agreements and collaborations among different actors......), with the discussion of the stakeholders’ roles and their interrelation in delivering energy flexibility with the influential factors to the actual implementation of energy flexible operation of their buildings. Based on a literature analysis, the results cover stakeholders’ types and roles, perceptions (drivers......, barriers, and benefits), energy management activities and technology adoptions, and the stakeholders’ interaction for the energy flexibility in retail buildings....

  20. Is the transposition of the nipple-areolar complex necessary in Simon grade 2b gynecomastia operations using suction-assisted liposuction?

    Science.gov (United States)

    Özalp, Burhan; Berköz, Ömer; Aydınol, Mustafa

    2018-02-01

    The aim of this study was to assess the efficacy of suction-assisted liposuction (SAL) in Simon grade 2b gynecomastia and its effect on sternal notch to nipple areola (SNN) distance. A retrospective analysis was performed on 21 patients with grade 2b gynecomastia who underwent SAL. Preoperative and postoperative SNN distances of the patients were measured, the results were analysed using a Mann-Whitney U test and a p-value gynecomastia and shortens the SNN distance by 1 cm, but further clinical studies are required to support this conclusion.

  1. Flexible Word Classes

    DEFF Research Database (Denmark)

    • First major publication on the phenomenon • Offers cross-linguistic, descriptive, and diverse theoretical approaches • Includes analysis of data from different language families and from lesser studied languages This book is the first major cross-linguistic study of 'flexible words', i.e. words...... that cannot be classified in terms of the traditional lexical categories Verb, Noun, Adjective or Adverb. Flexible words can - without special morphosyntactic marking - serve in functions for which other languages must employ members of two or more of the four traditional, 'specialised' word classes. Thus......, flexible words are underspecified for communicative functions like 'predicating' (verbal function), 'referring' (nominal function) or 'modifying' (a function typically associated with adjectives and e.g. manner adverbs). Even though linguists have been aware of flexible world classes for more than...

  2. Flexible magnetoimpedance sensor

    KAUST Repository

    Li, Bodong; Kavaldzhiev, Mincho; Kosel, Jü rgen

    2015-01-01

    Flexible magnetoimpedance (MI) sensors fabricated using a NiFe/Cu/NiFe tri-layer on Kapton substrate have been studied. A customized flexible microstrip transmission line was employed to investigate the MI sensors's magnetic field and frequency

  3. Treatment of cellulite with a bipolar radiofrequency, infrared heat, and pulsatile suction device: a pilot study.

    Science.gov (United States)

    Wanitphakdeedecha, Rungsima; Manuskiatti, Woraphong

    2006-12-01

    Very few therapeutic options have proven effective in the treatment of cellulite. To evaluate the effectiveness and adverse effects of a bipolar radiofrequency (RF), infrared (IR) heat and pulsatile suction device for the treatment of cellulite. Twelve subjects were treated with the RF-light-based device. All subjects were treated twice weekly for a total number of eight to nine treatments. Subjects were evaluated using standardized photographs, and measurements of body weight and circumference of treatment sites at baseline, immediately after the last treatment, and four weeks and one year after the last treatment. Clinical improvement scores of comparable photographs using a quartile grading scale (0 = 75% improvement) were judged independently by two non-treating dermatologists after the series of treatment. The average body weights at baseline, immediately after the last treatment, and four weeks and one year after the complete treatment were 56.30, 56.05, 56.23, and 56.53 kg, respectively. The average circumferential reductions of the abdomen and thigh at the last treatment visit were 5.17 +/- 1.04 cm (6.32%+/- 1.82%) and 3.50 +/- 2.16 cm (6.23 +/- 3.58%), respectively. At four weeks after the last treatment, the average circumferential reductions of the abdomen and thigh were sustained at 3.17 +/- 2.75 cm (4.04%+/- 3.69%) and 3.50 +/- 2.04 cm (6.26%+/- 3.52%), respectively. At one year follow-up visit, the average circumferential reductions of the abdomen and thigh were maintained at 3.83 +/- 0.76 cm (4.64%+/- 1.15%) and 3.13 +/- 3.54 (5.50%+/- 6.12%), respectively. Average clinical improvement scores of the abdomen and thigh after the series of treatments were 0.75 (corresponding to approximately 25% improvement), and 1.75 (corresponding to approximately 50% improvement), respectively. A bipolar RF, IR heat and pulsatile suction device provides a beneficial effect on reduction of abdomen and thigh circumference, and smoothening of the cellulite.

  4. Flexible magnetoimpedance sensor

    International Nuclear Information System (INIS)

    Li, Bodong; Kavaldzhiev, Mincho N.; Kosel, Jürgen

    2015-01-01

    Flexible magnetoimpedance (MI) sensors fabricated using a NiFe/Cu/NiFe tri-layer on Kapton substrate have been studied. A customized flexible microstrip transmission line was employed to investigate the MI sensors's magnetic field and frequency responses and their dependence on the sensors's deflection. For the first time, the impedance characteristic is obtained through reflection coefficient analysis over a wide range of frequencies from 0.1 MHz to 3 GHz and for deflections ranging from zero curvature to a radius of 7.2 cm. The sensor element maintains a high MI ratio of up to 90% and magnetic sensitivity of up to 9.2%/Oe over different bending curvatures. The relationship between the curvature and material composition is discussed based on the magnetostriction effect and stress simulations. The sensor's large frequency range, simple fabrication process and high sensitivity provide a great potential for flexible electronics and wireless applications. - Highlights: • A flexible magnetoimpedance (MI) sensor is developed. • Studies are carried out using a flexible microstrip transmission line. • An MI ratio of up to 90% is obtained. • The effect of magnetostriction is studied

  5. Flexible transparent electrode

    Science.gov (United States)

    Demiryont, Hulya; Shannon, Kenneth C., III; Moorehead, David; Bratcher, Matthew

    2011-06-01

    This paper presents the properties of the EclipseTECTM transparent conductor. EclipseTECTM is a room temperature deposited nanostructured thin film coating system comprised of metal-oxide semiconductor elements. The system possesses metal-like conductivity and glass-like transparency in the visible region. These highly conductive TEC films exhibit high shielding efficiency (35dB at 1 to 100GHz). EclipseTECTM can be deposited on rigid or flexible substrates. For example, EclipseTECTM deposited on polyethylene terephthalate (PET) is extremely flexible that can be rolled around a 9mm diameter cylinder with little or no reduction in electrical conductivity and that can assume pre-extension states after an applied stress is relieved. The TEC is colorless and has been tailored to have high visible transmittance which matches the eye sensitivity curve and allows the viewing of true background colors through the coating. EclipseTECTM is flexible, durable and can be tailored at the interface for applications such as electron- or hole-injecting OLED electrodes as well as electrodes in flexible displays. Tunable work function and optical design flexibility also make EclipseTECTM well-suited as a candidate for grid electrode replacement in next-generation photovoltaic cells.

  6. Flexible Foam Model.

    Energy Technology Data Exchange (ETDEWEB)

    Neilsen, Michael K.; Lu, Wei-Yang; Werner, Brian T.; Scherzinger, William M.; Lo, Chi S.

    2018-03-01

    Experiments were performed to characterize the mechanical response of a 15 pcf flexible polyurethane foam to large deformation at different strain rates and temperatures. Results from these experiments indicated that at room temperature, flexible polyurethane foams exhibit significant nonlinear elastic deformation and nearly return to their original undeformed shape when unloaded. However, when these foams are cooled to temperatures below their glass transition temperature of approximately -35 o C, they behave like rigid polyurethane foams and exhibit significant permanent deformation when compressed. Thus, a new model which captures this dramatic change in behavior with temperature was developed and implemented into SIERRA with the name Flex_Foam to describe the mechanical response of both flexible and rigid foams to large deformation at a variety of temperatures and strain rates. This report includes a description of recent experiments. Next, development of the Flex Foam model for flexible polyurethane and other flexible foams is described. Selection of material parameters are discussed and finite element simulations with the new Flex Foam model are compared with experimental results to show behavior that can be captured with this new model.

  7. Vortex generation and wave-vortex interaction over a concave plate with roughness and suction

    Science.gov (United States)

    Bertolotti, Fabio

    1993-01-01

    The generation and amplification of vortices by surface homogeneities, both in the form of surface waviness and of wall-normal velocity, is investigated using the nonlinear parabolic stability equations. Transients and issues of algebraic growth are avoided through the use of a similarity solution as initial condition for the vortex. In the absence of curvature, the vortex decays as the square root of 1/x when flowing over streamwise aligned riblets of constant height, and grows as the square root of x when flowing over a corresponding streamwise aligned variation of blowing/suction transpiration velocity. However, in the presence of wall inhomogeneities having both streamwise and spanwise periodicity, the growth of the vortex can be much larger. In the presence of curvature, the vortex develops into a Gortler vortex. The 'direct' and 'indirect' interaction mechanisms possible in wave-vortex interaction are presented. The 'direct' interaction does not lead to strong resonance with the flow conditions investigated. The 'indirect' interaction leads to K-type transition.

  8. The Importance of Pressure Sampling Frequency in Models for Determination of Critical Wave Loadingson Monolithic Structures

    DEFF Research Database (Denmark)

    Burcharth, Hans F.; Andersen, Thomas Lykke; Meinert, Palle

    2008-01-01

    This paper discusses the influence of wave load sampling frequency on calculated sliding distance in an overall stability analysis of a monolithic caisson. It is demonstrated by a specific example of caisson design that for this kind of analyses the sampling frequency in a small scale model could...... be as low as 100 Hz in model scale. However, for design of structure elements like the wave wall on the top of a caisson the wave load sampling frequency must be much higher, in the order of 1000 Hz in the model. Elastic-plastic deformations of foundation and structure were not included in the analysis....

  9. Effect of Reynolds Number and Periodic Unsteady Wake Flow Condition on Boundary Layer Development, Separation, and Intermittency Behavior Along the Suction Surface of a Low Pressure Turbine Blade

    Science.gov (United States)

    Schobeiri, M. T.; Ozturk, B.; Ashpis, David E.

    2007-01-01

    The paper experimentally studies the effects of periodic unsteady wake flow and different Reynolds numbers on boundary layer development, separation and re-attachment along the suction surface of a low pressure turbine blade. The experimental investigations were performed on a large scale, subsonic unsteady turbine cascade research facility at Turbomachinery Performance and Flow Research Laboratory (TPFL) of Texas A&M University. The experiments were carried out at Reynolds numbers of 110,000 and 150,000 (based on suction surface length and exit velocity). One steady and two different unsteady inlet flow conditions with the corresponding passing frequencies, wake velocities, and turbulence intensities were investigated. The reduced frequencies chosen cover the operating range of LP turbines. In addition to the unsteady boundary layer measurements, surface pressure measurements were performed. The inception, onset, and the extent of the separation bubble information collected from the pressure measurements were compared with the hot wire measurements. The results presented in ensemble-averaged, and the contour plot forms help to understand the physics of the separation phenomenon under periodic unsteady wake flow and different Reynolds number. It was found that the suction surface displayed a strong separation bubble for these three different reduced frequencies. For each condition, the locations defining the separation bubble were determined carefully analyzing and examining the pressure and mean velocity profile data. The location of the boundary layer separation was dependent of the Reynolds number. It is observed that starting point of the separation bubble and the re-attachment point move further downstream by increasing Reynolds number from 110,000 to 150,000. Also, the size of the separation bubble is smaller when compared to that for Re=110,000.

  10. 75 FR 65483 - Proposed Reissuance of General NPDES Permits (GP) for Alaskan Medium-Size Suction Dredging...

    Science.gov (United States)

    2010-10-25

    ... ADEC, EPA will complete work on any project where substantial work has been initiated prior to the... 6 of that order. Regulatory Flexibility Act: Under the Regulatory Flexibility Act (RFA), 5 U.S.C. 601 et seq., a Federal agency must prepare an initial regulatory flexibility analysis ``for any...

  11. Design, test and start up of a cleaning system for the moderator tank bottom of Atucha I Nuclear Power Plant

    International Nuclear Information System (INIS)

    Duca, J.; Gerber, O.; Ibero, M.; Riga, N.

    1989-01-01

    In order to perform the cleaning of the moderator tank bottom, during the repair of the Atucha I nuclear power plant (CNA I) failure, the Empresa Nuclear Argentina de Centrales Electricas (ENACE S.A.) designed a system with the following requirements (asked by CNA I): a) To aspirate and retain free solid particles, uranium dioxide pellets and coolant channels isolations (foils) of minor size settled at the moderator tank bottom, being the reactor at middle loop state. b) To allow a radially cleaning up to 1.4 m from the extracted channel. c) To design a lay-out attaining the ALARA dose exposure. The designed system basically consists in: a) Flexible intake for suction: allows the movement inside the moderator tank and provides the adequate speed to raise the particles. b) Filter: retains the aspirated particles, pellets and foils. Its capacity is 1.8 dm 3 and the minimum size of retained particles is 200 m. The ALARA dose exposure concept is attained due to that the filter is located inside the moderator tank. c) Filtering column: contains the filter and allows the entrance of the extraction and exchange tool (for the flexible intake and filter). d) Suction hose: connects the filtering column with the pump. Its flexibility allows its use in any channel maintaining the same positions of the discharge pump and the return piping. e) Discharge pump: it is a canned centrifugal pump with low-low net positive suction head. f) Return piping: discharges the filtered water into the moderator tank. The system fulfilled satisfactorily all requirements during its operation. (Author)

  12. Incentivizing Flexibility in System Operations

    Energy Technology Data Exchange (ETDEWEB)

    Milligan, Michael [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Bloom, Aaron P [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Townsend, Aaron [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Ela, Erik [Electric Power Research Institute; Botterud, Audun [Argonne National Laboratory; Levin, Todd [Argonne National Laboratory

    2018-02-15

    Defining flexibility has been a challenge that a number of industry members and researchers have attempted to address in recent years. With increased variability and uncertainty of variable generation (VG), the resources on the system will have to be more flexible to adjust output, so that power output ranges, power ramp rates, and energy duration sustainability are sufficient to meet the needs of balancing supply with demand at various operational timescales. This chapter discusses whether existing market designs provide adequate incentives for resources to offer their flexibility into the market to meet the increased levels of variability and uncertainty introduced by VG in the short-term operational time frame. It presents a definition of flexibility and discusses how increased levels of VG require increased needs for flexibility on power systems. Following this introductory material, the chapter examines how existing market designs ensure that resources have the right incentives to provide increased flexibility, and then discusses a number of emerging market design elements that impact flexibility incentives.

  13. A Giant Chelonioid Turtle from the Late Cretaceous of Morocco with a Suction Feeding Apparatus Unique among Tetrapods

    Science.gov (United States)

    Bardet, Nathalie; Jalil, Nour-Eddine; de Lapparent de Broin, France; Germain, Damien; Lambert, Olivier; Amaghzaz, Mbarek

    2013-01-01

    Background Secondary adaptation to aquatic life occurred independently in several amniote lineages, including reptiles during the Mesozoic and mammals during the Cenozoic. These evolutionary shifts to aquatic environments imply major morphological modifications, especially of the feeding apparatus. Mesozoic (250–65 Myr) marine reptiles, such as ichthyosaurs, plesiosaurs, mosasaurid squamates, crocodiles, and turtles, exhibit a wide range of adaptations to aquatic feeding and a broad overlap of their tooth morphospaces with those of Cenozoic marine mammals. However, despite these multiple feeding behavior convergences, suction feeding, though being a common feeding strategy in aquatic vertebrates and in marine mammals in particular, has been extremely rarely reported for Mesozoic marine reptiles. Principal Findings A relative of fossil protostegid and dermochelyoid sea turtles, Ocepechelon bouyai gen. et sp. nov. is a new giant chelonioid from the Late Maastrichtian (67 Myr) of Morocco exhibiting remarkable adaptations to marine life (among others, very dorsally and posteriorly located nostrils). The 70-cm-long skull of Ocepechelon not only makes it one of the largest marine turtles ever described, but also deviates significantly from typical turtle cranial morphology. It shares unique convergences with both syngnathid fishes (unique long tubular bony snout ending in a rounded and anteriorly directed mouth) and beaked whales (large size and elongated edentulous jaws). This striking anatomy suggests extreme adaptation for suction feeding unmatched among known turtles. Conclusion/Significance The feeding apparatus of Ocepechelon, a bony pipette-like snout, is unique among tetrapods. This new taxon exemplifies the successful systematic and ecological diversification of chelonioid turtles during the Late Cretaceous. This new evidence for a unique trophic specialization in turtles, along with the abundant marine vertebrate faunas associated to Ocepechelon in the Late

  14. A giant chelonioid turtle from the late Cretaceous of Morocco with a suction feeding apparatus unique among tetrapods.

    Science.gov (United States)

    Bardet, Nathalie; Jalil, Nour-Eddine; de Lapparent de Broin, France; Germain, Damien; Lambert, Olivier; Amaghzaz, Mbarek

    2013-01-01

    Secondary adaptation to aquatic life occurred independently in several amniote lineages, including reptiles during the Mesozoic and mammals during the Cenozoic. These evolutionary shifts to aquatic environments imply major morphological modifications, especially of the feeding apparatus. Mesozoic (250-65 Myr) marine reptiles, such as ichthyosaurs, plesiosaurs, mosasaurid squamates, crocodiles, and turtles, exhibit a wide range of adaptations to aquatic feeding and a broad overlap of their tooth morphospaces with those of Cenozoic marine mammals. However, despite these multiple feeding behavior convergences, suction feeding, though being a common feeding strategy in aquatic vertebrates and in marine mammals in particular, has been extremely rarely reported for Mesozoic marine reptiles. A relative of fossil protostegid and dermochelyoid sea turtles, Ocepechelon bouyai gen. et sp. nov. is a new giant chelonioid from the Late Maastrichtian (67 Myr) of Morocco exhibiting remarkable adaptations to marine life (among others, very dorsally and posteriorly located nostrils). The 70-cm-long skull of Ocepechelon not only makes it one of the largest marine turtles ever described, but also deviates significantly from typical turtle cranial morphology. It shares unique convergences with both syngnathid fishes (unique long tubular bony snout ending in a rounded and anteriorly directed mouth) and beaked whales (large size and elongated edentulous jaws). This striking anatomy suggests extreme adaptation for suction feeding unmatched among known turtles. The feeding apparatus of Ocepechelon, a bony pipette-like snout, is unique among tetrapods. This new taxon exemplifies the successful systematic and ecological diversification of chelonioid turtles during the Late Cretaceous. This new evidence for a unique trophic specialization in turtles, along with the abundant marine vertebrate faunas associated to Ocepechelon in the Late Maastrichtian phosphatic beds of Morocco, further

  15. A giant chelonioid turtle from the late Cretaceous of Morocco with a suction feeding apparatus unique among tetrapods.

    Directory of Open Access Journals (Sweden)

    Nathalie Bardet

    Full Text Available BACKGROUND: Secondary adaptation to aquatic life occurred independently in several amniote lineages, including reptiles during the Mesozoic and mammals during the Cenozoic. These evolutionary shifts to aquatic environments imply major morphological modifications, especially of the feeding apparatus. Mesozoic (250-65 Myr marine reptiles, such as ichthyosaurs, plesiosaurs, mosasaurid squamates, crocodiles, and turtles, exhibit a wide range of adaptations to aquatic feeding and a broad overlap of their tooth morphospaces with those of Cenozoic marine mammals. However, despite these multiple feeding behavior convergences, suction feeding, though being a common feeding strategy in aquatic vertebrates and in marine mammals in particular, has been extremely rarely reported for Mesozoic marine reptiles. PRINCIPAL FINDINGS: A relative of fossil protostegid and dermochelyoid sea turtles, Ocepechelon bouyai gen. et sp. nov. is a new giant chelonioid from the Late Maastrichtian (67 Myr of Morocco exhibiting remarkable adaptations to marine life (among others, very dorsally and posteriorly located nostrils. The 70-cm-long skull of Ocepechelon not only makes it one of the largest marine turtles ever described, but also deviates significantly from typical turtle cranial morphology. It shares unique convergences with both syngnathid fishes (unique long tubular bony snout ending in a rounded and anteriorly directed mouth and beaked whales (large size and elongated edentulous jaws. This striking anatomy suggests extreme adaptation for suction feeding unmatched among known turtles. CONCLUSION/SIGNIFICANCE: The feeding apparatus of Ocepechelon, a bony pipette-like snout, is unique among tetrapods. This new taxon exemplifies the successful systematic and ecological diversification of chelonioid turtles during the Late Cretaceous. This new evidence for a unique trophic specialization in turtles, along with the abundant marine vertebrate faunas associated to

  16. [Study and development of a new automatic suction system (SS) of intratracheal sputum in order to improve QOL of many patients with tracheostomy mechanical ventilation (TMV) and their family members by this new autonomic SS].

    Science.gov (United States)

    Hokezu, Youichi; Yamamoto, Makoto; Tokunaga, Syuichi; Niikura, Makoto; Nagamatsu, Keiji; Kira, Jun-ichi; Fukunaga, Toshihide; Shima, Kouji; Kikuchi, Seiji; Kimura, Itaru; Kondo, Kiyohiko; Mori, Teruhiko; Goto, Katumasa; Takigami, Shigeru; Shioya, Keiichi; Uehara, Minako

    2009-11-01

    In Japan, many patients equipped with TMV are under medical treatment at home after 1990. These patients can't put out sputa in trachea, so that these patient's family members must suck these patient's intratracheal sputa all days. Mr Yamamoto and Mr Tokunaga, main researchers of this study, began the study on the automatic SS of itratracheal sputa from 1999. In first stage, They developed the intermittent SS in detaining the suction tube within tracheal cannula, monitering the intratracheal pressure, but this system takes the ventilation away from the patient. Hypoventilation caused by this SS may cause the serious accident in patient. Therefore, we remodel the SS from intermittent SS to rollerpomp-type SS continuing to suck the itratracheal sputa with low volume from 2004, and thereafter we made up the SS of piston pomp type-SS finally at 2007. We developed the tracheal cannula with double suction holes of inner and lower hole in the lower part of its cannula together with the suction machine. We think that the practical use of this automatic SS will bring these patients with TMV and their family members great benefits. We desire that the practical use of this SS will be realized as soon as possible.

  17. Graphene-based materials for flexible supercapacitors.

    Science.gov (United States)

    Shao, Yuanlong; El-Kady, Maher F; Wang, Lisa J; Zhang, Qinghong; Li, Yaogang; Wang, Hongzhi; Mousavi, Mir F; Kaner, Richard B

    2015-06-07

    The demand for flexible/wearable electronic devices that have aesthetic appeal and multi-functionality has stimulated the rapid development of flexible supercapacitors with enhanced electrochemical performance and mechanical flexibility. After a brief introduction to flexible supercapacitors, we summarize current progress made with graphene-based electrodes. Two recently proposed prototypes for flexible supercapacitors, known as micro-supercapacitors and fiber-type supercapacitors, are then discussed. We also present our perspective on the development of graphene-based electrodes for flexible supercapacitors.

  18. Flexible Metal Oxide/Graphene Oxide Hybrid Neuromorphic Devices on Flexible Conducting Graphene Substrates

    OpenAIRE

    Wan, Chang Jin; Wang, Wei; Zhu, Li Qiang; Liu, Yang Hui; Feng, Ping; Liu, Zhao Ping; Shi, Yi; Wan, Qing

    2016-01-01

    Flexible metal oxide/graphene oxide hybrid multi-gate neuron transistors were fabricated on flexible graphene substrates. Dendritic integrations in both spatial and temporal modes were successfully emulated, and spatiotemporal correlated logics were obtained. A proof-of-principle visual system model for emulating lobula giant motion detector neuron was investigated. Our results are of great interest for flexible neuromorphic cognitive systems.

  19. Flexible Electronics Research Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Flexible Electronics Research Facility designs, synthesizes, tests, and fabricates materials and devices compatible with flexible substrates for Army information...

  20. Flexibility within Fidelity

    Science.gov (United States)

    Kendall, Philip C.; Gosch, Elizabeth; Furr, Jami M.; Sood, Erica

    2008-01-01

    The authors address concerns regarding manual-based treatments, highlighting the role of flexibility and creativity. A cognitive-behavioral therapy for youth anxiety called the Coping Cat program demonstrates the flexible application of manuals and emphasizes the importance of a child-centered, personalized approach that involves the child in the…

  1. WAGE FLEXIBILITY IN THE CONTEMPORARY SOCIETY

    Directory of Open Access Journals (Sweden)

    TECULESCU Silviu Alexandru

    2010-12-01

    Full Text Available The paper follows to offer the most efficient solutions for the attainment by Romania of the economic development level associated to the Western European countries. It proposes the division of the flexibility of labour market in three components, namely: internal flexibility, external flexibility and wage flexibility. The analysis performed within the present study will emphasize the wage flexibility. Wage flexibility can be classified in four components: a plans of individual and group incentives; b plans of assigning wages out of productivity; c plans of distribution of profits and, respectively, d plans of suggestions. The labour market flexibility, in general, and especially the wage flexibility contributes to the increase of employee motivation at the workplace, aspect which leeds to the growth of labour productivity, through this one being put the bases of the medium- and long-term economic development.

  2. Energy Flexibility in the Power System

    DEFF Research Database (Denmark)

    Billanes, Joy Dalmacio; Ma, Zheng; Jørgensen, Bo Nørregaard

    2017-01-01

    Energy flexibility can address the challenges of large scale integration of renewable energy resources and thereby increasing imbalance in the power system. Flexible power system can provide reliable supply, low electricity cost and sustainability. Various situations and factors influence...... the adoption of the flexibility solutions, such as flexible electricity generation, demand-response, and electricity storage. This paper tries to analyze the current energy flexibility solutions and the factors that can influence the energy flexibility adoption. This paper takes Philippines as case study...... to provide an overview of the current condition of the Philippines’ power system and discuss the energy flexibility in the Philippines’ power system. A further discussion and recommendation is conducted in the end of the paper....

  3. Organizational flexibility estimation

    OpenAIRE

    Komarynets, Sofia

    2013-01-01

    By the help of parametric estimation the evaluation scale of organizational flexibility and its parameters was formed. Definite degrees of organizational flexibility and its parameters for the Lviv region enterprises were determined. Grouping of the enterprises under the existing scale was carried out. Special recommendations to correct the enterprises behaviour were given.

  4. Caracterización de la succión en el lactante según la rehabilitación neuro-oclusal Characterization of newborn suction according the neuro-occlusal rehabilitation

    Directory of Open Access Journals (Sweden)

    Dania Santos Prieto

    2010-09-01

    Full Text Available En el primer mes de vida del niño, la succión juega un papel fundamental para fijar las praxias bucales básicas, que constituyen el patrón funcional de base para el desarrollo y maduración de las funciones del sistema estomatognático del niño mayor y del adulto. Se realizó un estudio descriptivo transversal con aplicación de métodos cuantitativos y recogida de datos cualitativos, para caracterizar el desarrollo de la succión del recién nacido, a través de la rehabilitación neuro-oclusal. El universo de esta investigación estuvo constituido por 56 niños pertenecientes al área de salud de la Policlínica "Santa Clara", en el periodo comprendido de septiembre a noviembre de 2008. Para la recogida de la información acerca de las variables objeto de estudio, se utilizó como instrumento la ficha de observación, que describió el momento de la succión de la leche materna. En el análisis del estudio, para ganar claridad en los resultados, se utilizaron análisis descriptivos y comparativos. La succión del lactante presentó dificultades asociadas a varios factores. Uno fue la posición inadecuada, caracterizada por la falta de alineación y la separación del cuerpo del bebé de la madre. Otro lo constituyó la anatomía de la mama, tal como los pechos ingurgitados y los pezones planos e invertidos. También hubo dificultades relacionadas con el acto mismo de succión, tales como la boca no muy abierta, más areola por debajo de la boca del bebé, el labio inferior invertido, el mentón sin tocar el pecho, y el chasqueo al deglutir. En los recién nacidos tomados como muestra de estudio predominó la succión ineficaz.During the first year of life of infant the suction plays a main role to fix the practical buccal praxis that are the basis functional pattern for development and maturation of Stomatognatic System functions of older child and of adult. A cross-sectional and descriptive study was conducted to apply the quantitative

  5. Inter-Vertebral Flexibility of the Ostrich Neck: Implications for Estimating Sauropod Neck Flexibility

    OpenAIRE

    Cobley, Matthew J.; Rayfield, Emily J.; Barrett, Paul M.

    2013-01-01

    The flexibility and posture of the neck in sauropod dinosaurs has long been contentious. Improved constraints on sauropod neck function will have major implications for what we know of their foraging strategies, ecology and overall biology. Several hypotheses have been proposed, based primarily on osteological data, suggesting different degrees of neck flexibility. This study attempts to assess the effects of reconstructed soft tissues on sauropod neck flexibility through systematic removal o...

  6. Flexible automated manufacturing for SMEs

    DEFF Research Database (Denmark)

    Grube Hansen, David; Bilberg, Arne; Madsen, Erik Skov

    2017-01-01

    SMEs are in general highly flexible and agile in order to accommodate the customer demands in the paradigm of High Mix-Low Volume manufacturing. The flexibility and agility have mainly been enabled by manual labor, but as we are entering the technology and data driven fourth industrial revolution......, where augmented operators and machines work in cooperation in a highly flexible and productive manufacturing system both an opportunity and a need has raised for developing highly flexible and efficient automation....

  7. On flexible and rigid nouns

    DEFF Research Database (Denmark)

    Rijkhoff, Jan

    2010-01-01

    classes. Finally this article wants to claim that the distinction between rigid and flexible noun categories (a) adds a new dimension to current classifications of parts of speech systems, (b) correlates with certain grammatical phenomena (e.g. so-called number discord), and (c) helps to explain the parts......This article argues that in addition to the major flexible lexical categories in Hengeveld’s classification of parts of speech systems (Contentive, Non-Verb, Modifier), there are also flexible word classes within the rigid lexical category Noun (Set Noun, Sort Noun, General Noun). Members...... by the flexible item in the external world. I will then argue that flexible word classes constitute a proper category (i.e. they are not the result of a merger of some rigid word classes) in that members of flexible word categories display the same properties regarding category membership as members of rigid word...

  8. On flexible and rigid nouns

    DEFF Research Database (Denmark)

    Rijkhoff, Jan

    2008-01-01

    Studies in Language 32-3 (2008), 727-752. Special issue: Parts of Speech: Descriptive tools, theoretical constructs Jan Rijkhoff - On flexible and rigid nouns This article argues that in addition to the flexible lexical categories in Hengeveld’s classification of parts-of-speech systems (Contentive......, Non-Verb, Modifier), there are also flexible word classes within the rigid lexical category Noun (Set Noun, Sort Noun, General Noun). Members of flexible word classes are characterized by their vague semantics, which in the case of nouns means that values for the semantic features Shape...... and Homogeneity are either left undetermined or they are specified in such a way that they do not quite match the properties of the kind of entity denoted by the flexible item in the external world. I will then argue that flexible word classes constitute a proper category (i.e. they are not the result of a merger...

  9. Flexible magnetoimpidence sensor

    KAUST Repository

    Kavaldzhiev, Mincho

    2015-05-01

    Recently, flexible electronic devices have attracted increasing interest, due to the opportunities they promise for new applications such as wearable devices, where the components are required to flex during normal use[1]. In this light, different magnetic sensors, like microcoil, spin valve, giant magnetoresistance (GMR), magnetoimpedance (MI), have been studied previously on flexible substrates.

  10. Global Analysis of Flexible Risers

    DEFF Research Database (Denmark)

    Banke, Lars

    1996-01-01

    Flexible pipes are often a technically attractive alternative to the traditional steel pipe. Often commercial utilisation of oil/gas fields depends on the use of flexible pipes. An example is when floating production vessels are used, where the flexible pipe follows the wave induced motions...

  11. Designing structural supply chain flexibility

    NARCIS (Netherlands)

    Mulinski, Ksawery Jan

    2012-01-01

    In a continuously changing business environment the role of supply chain flexibility is constantly increasing. A flexible supply chain can ensure survival in quickly changing market conditions as well as enable sustainable growth. This thesis explores the topic of supply chain flexibility with focus

  12. Apparatus and process for recovering petroleum spread on the surface of water

    Energy Technology Data Exchange (ETDEWEB)

    Sourdis, P

    1968-05-06

    A flexible suction tube is towed by means of 2 or more cables in a direction substantially perpendicular to the axis of the tube. The tube is made of light plastic and has a longitudinal slot over its entire length; the width of the slot can be made adjustable. The interior of the suction tube is connected through tubes with a discharge tube in which the liquid level can vary between certain limits. The discharge tube is equipped with floats and steering surfaces to maintain its position in the water; its ends are connected to the pumps on a ship. This assembly is used in conjunction with a flexible, ballasted barrier filled with air to insure its buoyancy. The barrier may consist of a flat plastic tube, or of sheet plastic wound on a core of foamed or expanded plastic. The barrier is stored aboard a tanker or aboard the pumping ship, and when in use, it is towed by one or several speedboats.

  13. Flexibility in insulin prescription

    Directory of Open Access Journals (Sweden)

    Sanjay Kalra

    2016-01-01

    Full Text Available This communication explores the concept of flexibility, a propos insulin preparations and insulin regimes used in the management of type 2 diabetes. The flexibility of an insulin regime or preparation is defined as their ability to be injected at variable times, with variable injection-meal time gaps, in a dose frequency and quantum determined by shared decision making, with a minimal requirement of glucose monitoring and health professional consultation, with no compromise on safety, efficiency and tolerability. The relative flexibility of various basal, prandial and dual action insulins, as well as intensive regimes, is compared. The biopsychosocial model of health is used to assess the utility of different insulins while encouraging a philosophy of flexible insulin usage.

  14. Comparing the role of subcision suction method with and without the injection of platelet-rich plasma in the treatment of depressed scars

    Directory of Open Access Journals (Sweden)

    Nouran Abd El-Aziz Abou Khedr

    2017-02-01

    Full Text Available Among wound-healing modalities, platelet-rich plasma (PRP has been used for wound healing, through the release of multiple growth factors. The platelets mediate wound healing by initiating the clotting pathway and the subsequent matrix remodelisation. The aim of the work was to study the role of injection of platelet-rich plasma in the treatment of scars. This study was conducted on thirty patients who were divided into two groups (A and B. Each group included fifteen patients. The two groups were randomly distributed by using individual sealed envelopes. Group A was subjected to subcision of their acne scars using Nokor needle, followed by suction. Group B patients were subjected to the same treatment but followed by an injection of platelet-rich plasma once per month over three months. In Group A, 6 patients (40% showed moderate improvement, 5 patients (33.3% showed slight improvement and 4 patients (26.7% showed significant improvement. In Group B, 7 patients (46.7% showed moderate improvement, 5 patients (33.3% showed marked improvement and 3 patients (20% showed significant improvement. There was a statistically significant difference on the independent observer’s after-treatment assessment between the groups (P=0.014. In conclusion, subcision suction leads to a persistent improvement of acne scars in a short time, and the coupling with injection of PRP is the most effective in the treatment of depressed facial scars.

  15. Rapid solidification of Ni50Nb28Zr22 glass former alloy through suction-casting

    International Nuclear Information System (INIS)

    Miyamoto, M.I.; Santos, F.S.; Bolfarini, C.; Botta Filho, W.J.; Kiminami, C.S.

    2010-01-01

    To select new alloys with high glass forming ability (GFA) to present amorphous structure in millimeter scale, several semi-empirical models have been developed. In the present work, a new alloy, Ni 50 Nb 28 Zr 22 d, was designed based on the combination of topological instability lambda (A) criterion and electronegativity difference (Δe). The alloy was rapidly solidified in a bulk wedge sample by cooper mold suction casting in order to investigate its amorphization. The sample was characterized by the combination of scanning electron microscopy (MEV), X-ray diffraction (XRD) and differential scanning calorimeter (DSC). For the minimum thickness of 200 μm analyzed, it was found that the alloy did not show a totally amorphous structure. Factor such as low cooling rate, existence of oxides on the surface of the elements and presence of oxygen in the atmosphere of equipment did not allowed the achievement of higher amorphous thickness. (author)

  16. Education for Flexible Personality

    Directory of Open Access Journals (Sweden)

    Bogomir Novak

    1998-12-01

    Full Text Available Flexible personality transforms both cultural environment and itself. Post-modern personality is both contemplative and active. On one hand, it is subject to inner imagination of a creative act, and on the other hand, to creation of a tangible product What is more, flexible personality is also autonomous, mature, healthy and well balanced, as well as stable and responsive to the demand for change. Due to ever quicker changes, flexible personality is a must. And it is a task. The impact of professional work of adults on the education of children, however, is being conditioned by the exrigid family and rigid enterprises or institutions in which adults are employed. Nevertheless, flexible educational style is not repressive, as it used to be, nor permissive and totally concentrated on the child. It is a choice between the two qualities. The educators' style is dependent on their attitude towards life (play and self-education and not only towards work. Nowadays, flexibility is a way towards quality management of social and personal changes.

  17. Composite Behavior of Insulated Concrete Sandwich Wall Panels Subjected to Wind Pressure and Suction

    Directory of Open Access Journals (Sweden)

    Insub Choi

    2015-03-01

    Full Text Available A full-scale experimental test was conducted to analyze the composite behavior of insulated concrete sandwich wall panels (ICSWPs subjected to wind pressure and suction. The experimental program was composed of three groups of ICSWP specimens, each with a different type of insulation and number of glass-fiber-reinforced polymer (GFRP shear grids. The degree of composite action of each specimen was analyzed according to the load direction, type of the insulation, and number of GFRP shear grids by comparing the theoretical and experimental values. The failure modes of the ICSWPs were compared to investigate the effect of bonds according to the load direction and type of insulation. Bonds based on insulation absorptiveness were effective to result in the composite behavior of ICSWP under positive loading tests only, while bonds based on insulation surface roughness were effective under both positive and negative loading tests. Therefore, the composite behavior based on surface roughness can be applied to the calculation of the design strength of ICSWPs with continuous GFRP shear connectors.

  18. Chemical reaction effect on an unsteady MHD free convection flow past a vertical porous plate in the presence of suction or injection

    Directory of Open Access Journals (Sweden)

    Shivaiah S.

    2012-01-01

    Full Text Available The objective of this paper is to analyze the effect of chemical reaction on unsteady magneto hydrodynamic free convective fluid flow past a vertical porous plate in the presence of suction or injection. The governing equations of the flow field are solved numerically by a finite element method. The effects of the various parameters on the velocity, temperature and concentration profiles are presented graphically and values of skin-friction coefficient, Nusselt number and Sherwood number for various values of physical parameters are presented through tables.

  19. Graphene-cellulose paper flexible supercapacitors

    Energy Technology Data Exchange (ETDEWEB)

    Weng, Zhe; Su, Yang; Li, Feng; Du, Jinhong; Cheng, Hui-Ming [Shenyang National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, 72 Wenhua Road, Shenyang 110016 (China); Wang, Da-Wei [ARC Centre of Excellence for Functional Nanomaterials, Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, St Lucia, Brisbane, Qld 4072 (Australia)

    2011-10-15

    A simple and scalable method to fabricate graphene-cellulose paper (GCP) membranes is reported; these membranes exhibit great advantages as freestanding and binder-free electrodes for flexible supercapacitors. The GCP electrode consists of a unique three-dimensional interwoven structure of graphene nanosheets and cellulose fibers and has excellent mechanical flexibility, good specific capacitance and power performance, and excellent cyclic stability. The electrical conductivity of the GCP membrane shows high stability with a decrease of only 6% after being bent 1000 times. This flexible GCP electrode has a high capacitance per geometric area of 81 mF cm{sup -2}, which is equivalent to a gravimetric capacitance of 120 F g{sup -1} of graphene, and retains >99% capacitance over 5000 cycles. Several types of flexible GCP-based polymer supercapacitors with various architectures are assembled to meet the power-energy requirements of typical flexible or printable electronics. Under highly flexible conditions, the supercapacitors show a high capacitance per geometric area of 46 mF cm{sup -2} for the complete devices. All the results demonstrate that polymer supercapacitors made using GCP membranes are versatile and may be used for flexible and portable micropower devices. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  20. FIST/6IB1, BWR/6 System Responses to Intermediate Break in Recirculation Suction Line LINE

    International Nuclear Information System (INIS)

    1993-01-01

    1 - Description of test facility: BWR/6-218 standard plant. A full size bundle with electrically heated rods is used to simulate the reactor core. A scaling ratio of 1/624 is applied in the design of the system components. Key features of the FIST facility include: (1) Full height test vessel and internals; (2) correctly scaled fluid volume distribution; (3) simulation of ECCS, S/RV, and ADS; (4) level trip capability; (5) heated feedwater supply system, which provides the capability for steady state operation. 2 - Description of test: Test 6IB1 investigates system responses to an intermediate break in the recirculation suction line. BWR system licensing evaluations for various size recirculation break LOCA's indicates that a break size of about 0.2 sq.ft., without LPCS operation, is the highest PCT case for the intermediate break LOCA. Test 6IB1 simulates this event

  1. Three-dimensional formulation of rigid-flexible multibody systems with flexible beam elements

    International Nuclear Information System (INIS)

    Garcia-Vallejo, D.; Mayo, J.; Escalona, J. L.; Dominguez, J.

    2008-01-01

    Multibody systems generally contain solids with appreciable deformations and which decisively influence the dynamics of the system. These solids have to be modeled by means of special formulations for flexible solids. At the same time, other solids are of such a high stiffness that they may be considered rigid, which simplifies their modeling. For these reasons, for a rigid-flexible multibody system, two types of formulations coexist in the equations of the system. Among the different possibilities provided in the literature on the material, the formulation in natural coordinates and the formulation in absolute nodal coordinates are utilized in this paper to model the rigid and flexible solids, respectively. This paper contains a mixed formulation based on the possibility of sharing coordinates between a rigid solid and a flexible solid. The global mass matrix of the system is shown to be constant and, in addition, many of the constraint equations obtained upon utilizing these formulations are linear and can be eliminated

  2. Development of the Coping Flexibility Scale: Evidence for the Coping Flexibility Hypothesis

    Science.gov (United States)

    Kato, Tsukasa

    2012-01-01

    "Coping flexibility" was defined as the ability to discontinue an ineffective coping strategy (i.e., evaluation coping) and produce and implement an alternative coping strategy (i.e., adaptive coping). The Coping Flexibility Scale (CFS) was developed on the basis of this definition. Five studies involving approximately 4,400 Japanese…

  3. Placement of percutaneous transhepatic biliary stent using a silicone drain with channels

    Science.gov (United States)

    Yoshida, Hiroshi; Mamada, Yasuhiro; Taniai, Nobuhiko; Mineta, Sho; Mizuguchi, Yoshiaki; Kawano, Yoichi; Sasaki, Junpei; Nakamura, Yoshiharu; Aimoto, Takayuki; Tajiri, Takashi

    2009-01-01

    This report describes a method for percutaneous transhepatic biliary stenting with a BLAKE Silicone Drain, and discusses the usefulness of placement of the drain connected to a J-VAC Suction Reservoir for the treatment of stenotic hepaticojejunostomy. Percutaneous transhepatic biliary drainage was performed under ultrasonographic guidance in a patient with stenotic hepaticojejunostomy after hepatectomy for hepatic hilum malignancy. The technique used was as follows. After dilatation of the drainage root, an 11-Fr tube with several side holes was passed through the stenosis of the hepaticojejunostomy. A 10-Fr BLAKE Silicone Drain is flexible, which precludes one-step insertion. One week after insertion of the 11-Fr tube, a 0.035-inch guidewire was inserted into the tube. After removal of the 11-Fr tube, the guidewire was put into the channel of a 10-Fr BLAKE Silicone Drain. The drain was inserted into the jejunal limb through the intrahepatic bile duct and was connected to a J-VAC Suction Reservoir. Low-pressure continued suction was applied. Patients can be discharged after insertion of the 10-Fr BLAKE Silicone Drain connected to the J-VAC Suction Reservoir. Placement of a percutaneous transhepatic biliary stent using a 10-Fr BLAKE Silicone Drain connected to a J-VAC Suction Reservoir is useful for the treatment of stenotic hepaticojejunostomy. PMID:19725159

  4. The Flexibility of Pusher Furnace Grate

    Directory of Open Access Journals (Sweden)

    Słowik J.A.

    2016-12-01

    Full Text Available The lifetime of guide grates in pusher furnaces for heat treatment could be increased by raising the flexibility of their structure through, for example, the replacement of straight ribs, parallel to the direction of grate movement, with more flexible segments. The deformability of grates with flexible segments arranged in two orientations, i.e. crosswise (perpendicular to the direction of compression and lengthwise (parallel to the direction of compression, was examined. The compression process was simulated using SolidWorks Simulation program. Relevant regression equations were also derived describing the dependence of force inducing the grate deformation by 0.25 mm ‒ modulus of grate elasticity ‒ on the number of flexible segments in established orientations. These calculations were made in Statistica and Scilab programs. It has been demonstrated that, with the same number of segments, the crosswise orientation of flexible segments increases the grate structure flexibility in a more efficient way than the lengthwise orientation. It has also been proved that a crucial effect on the grate flexibility has only the quantity and orientation of segments (crosswise / lengthwise, while the exact position of segments changes the grate flexibility by less than 1%.

  5. High Performance Electronics on Flexible Silicon

    KAUST Repository

    Sevilla, Galo T.

    2016-09-01

    Over the last few years, flexible electronic systems have gained increased attention from researchers around the world because of their potential to create new applications such as flexible displays, flexible energy harvesters, artificial skin, and health monitoring systems that cannot be integrated with conventional wafer based complementary metal oxide semiconductor processes. Most of the current efforts to create flexible high performance devices are based on the use of organic semiconductors. However, inherent material\\'s limitations make them unsuitable for big data processing and high speed communications. The objective of my doctoral dissertation is to develop integration processes that allow the transformation of rigid high performance electronics into flexible ones while maintaining their performance and cost. In this work, two different techniques to transform inorganic complementary metal-oxide-semiconductor electronics into flexible ones have been developed using industry compatible processes. Furthermore, these techniques were used to realize flexible discrete devices and circuits which include metal-oxide-semiconductor field-effect-transistors, the first demonstration of flexible Fin-field-effect-transistors, and metal-oxide-semiconductors-based circuits. Finally, this thesis presents a new technique to package, integrate, and interconnect flexible high performance electronics using low cost additive manufacturing techniques such as 3D printing and inkjet printing. This thesis contains in depth studies on electrical, mechanical, and thermal properties of the fabricated devices.

  6. Workplace flexibility: from research to action.

    Science.gov (United States)

    Galinsky, Ellen; Sakai, Kelly; Wigton, Tyler

    2011-01-01

    Ellen Galinsky, Kelly Sakai, and Tyler Wigton explore the "time famine" among American workers-the continuing sense among employees of not having enough time to manage the multiple responsibilities of work and personal and family life. Noting that large shares of U.S. employees report feeling the need for greater workplace flexibility to enable them to take better care of family responsibilities, the authors examine a large-scale community-engagement initiative to increase workplace flexibility voluntarily. Using the 2008 National Study of the Changing Workforce as a primary source of data, the authors begin with an overview of the prevalence of flexibility in today's American workplace. They track which categories of employees have access to various flexibility options, as well as the extent to which employees with access to various types of flexibility use those options. Findings from the study indicate that the majority of employees want flexibility but that access to it varies, with more advantaged employees--those who are well educated, have high salaries, and work full time, for example--being doubly advantaged in having greater access to flexibility. A number of employers, say the authors, tend to be skeptical of the value of workplace flexibility and to fear that employees will abuse it if it is offered. But the study data reveal that most employees use flexibility quite conservatively. When the authors use their nationally representative data set to investigate correlations between access to workplace flexibility and a range of workplace outcomes especially valued by employers--employee engagement, job satisfaction, retention, and health--they find that employers as well as employees can benefit from flexibility. Finally, the authors discuss When Work Works, a large, national community-based initiative under way since 2003 to increase voluntary adoption of workplace flexibility. The authors detail the conceptual basis of the project's design, noting its

  7. Free-form Flexible Lithium-Ion Microbattery

    KAUST Repository

    Kutbee, Arwa T.; Ghoneim, Mohamed T.; Ahmed, Sally; Hussain, Muhammad Mustafa

    2016-01-01

    Wearable electronics need miniaturized, safe and flexible power sources. Lithium ion battery is a strong candidate as high performance flexible battery. The development of flexible materials for battery electrodes suffers from the limited material

  8. Cognitive Flexibility in Obsessive Compulsive Disorder

    DEFF Research Database (Denmark)

    Jónsson, Hjalti; Salkovskis, Paul M.

    BT for problems such as OCD requires a level of cognitive flexibility (that is the ability to take a different perspective on ones problems). It could be argued that problems in set shifting (by neuropsychological tests) might underpin problems in this area. Two assessments were used (1: perception...... of cognitive flexibility was assessed by questionnaire 2: neuropsychological evaluation of set shifting). This study will recruit three groups: OCD patients, anxious and healthy controls. Cognitive flexibility is measured using modified version of the Cognitive Flexibility Scale (Martin & Rubin, 1995......) and neuropsychological measures of cognitive flexibility (Wisconsin Cart Sorting Test, Trail Making Test A/B, The Brixton Test). IN addition to the group comparison, the relationship between perceived flexibility, set shifting and psychopathology will be investigated. The implications of the findings for treatment...

  9. Flexible packaging for PV modules

    Science.gov (United States)

    Dhere, Neelkanth G.

    2008-08-01

    Economic, flexible packages that provide needed level of protection to organic and some other PV cells over >25-years have not yet been developed. However, flexible packaging is essential in niche large-scale applications. Typical configuration used in flexible photovoltaic (PV) module packaging is transparent frontsheet/encapsulant/PV cells/flexible substrate. Besides flexibility of various components, the solder bonds should also be flexible and resistant to fatigue due to cyclic loading. Flexible front sheets should provide optical transparency, mechanical protection, scratch resistance, dielectric isolation, water resistance, UV stability and adhesion to encapsulant. Examples are Tefzel, Tedlar and Silicone. Dirt can get embedded in soft layers such as silicone and obscure light. Water vapor transmittance rate (WVTR) of polymer films used in the food packaging industry as moisture barriers are ~0.05 g/(m2.day) under ambient conditions. In comparison, light emitting diodes employ packaging components that have WVTR of ~10-6 g/(m2.day). WVTR of polymer sheets can be improved by coating them with dense inorganic/organic multilayers. Ethylene vinyl acetate, an amorphous copolymer used predominantly by the PV industry has very high O2 and H2O diffusivity. Quaternary carbon chains (such as acetate) in a polymer lead to cleavage and loss of adhesional strength at relatively low exposures. Reactivity of PV module components increases in presence of O2 and H2O. Adhesional strength degrades due to the breakdown of structure of polymer by reactive, free radicals formed by high-energy radiation. Free radical formation in polymers is reduced when the aromatic rings are attached at regular intervals. This paper will review flexible packaging for PV modules.

  10. Flexible devices: from materials, architectures to applications

    Science.gov (United States)

    Zou, Mingzhi; Ma, Yue; Yuan, Xin; Hu, Yi; Liu, Jie; Jin, Zhong

    2018-01-01

    Flexible devices, such as flexible electronic devices and flexible energy storage devices, have attracted a significant amount of attention in recent years for their potential applications in modern human lives. The development of flexible devices is moving forward rapidly, as the innovation of methods and manufacturing processes has greatly encouraged the research of flexible devices. This review focuses on advanced materials, architecture designs and abundant applications of flexible devices, and discusses the problems and challenges in current situations of flexible devices. We summarize the discovery of novel materials and the design of new architectures for improving the performance of flexible devices. Finally, we introduce the applications of flexible devices as key components in real life. Project supported by the National Key R&D Program of China (Nos. 2017YFA0208200, 2016YFB0700600, 2015CB659300), the National Natural Science Foundation of China (Nos. 21403105, 21573108), and the Fundamental Research Funds for the Central Universities (No. 020514380107).

  11. Developmental constraints on behavioural flexibility.

    Science.gov (United States)

    Holekamp, Kay E; Swanson, Eli M; Van Meter, Page E

    2013-05-19

    We suggest that variation in mammalian behavioural flexibility not accounted for by current socioecological models may be explained in part by developmental constraints. From our own work, we provide examples of constraints affecting variation in behavioural flexibility, not only among individuals, but also among species and higher taxonomic units. We first implicate organizational maternal effects of androgens in shaping individual differences in aggressive behaviour emitted by female spotted hyaenas throughout the lifespan. We then compare carnivores and primates with respect to their locomotor and craniofacial adaptations. We inquire whether antagonistic selection pressures on the skull might impose differential functional constraints on evolvability of skulls and brains in these two orders, thus ultimately affecting behavioural flexibility in each group. We suggest that, even when carnivores and primates would theoretically benefit from the same adaptations with respect to behavioural flexibility, carnivores may nevertheless exhibit less behavioural flexibility than primates because of constraints imposed by past adaptations in the morphology of the limbs and skull. Phylogenetic analysis consistent with this idea suggests greater evolutionary lability in relative brain size within families of primates than carnivores. Thus, consideration of developmental constraints may help elucidate variation in mammalian behavioural flexibility.

  12. The experience of caesarean scar pregnancy treated with suction curettage under hysterocopy guidance%宫腔镜监测下清宫术治疗剖宫产瘢痕妊娠

    Institute of Scientific and Technical Information of China (English)

    曹毅; 肖琳; 唐良萏

    2011-01-01

    Objective:To describe our experience on the treatment of caesarean sear pregnancy with suction and curettage under hysterascopy guidance. Methods: Seven patients diagnosed as caesarean section sear pregnancy treated in our department underwent suction curettage under hystcroseopy between 2007 and 2009. Medical records and hysterecopy pictures of seven cases were collected and reviewed. Results: Four of them had complete suction cnrretage and uneventful outcome. Two had incomplete evacuation and small amount of hemorrhage. After Systemic MTX treatment, serum β- hCG decreased and pregnancy remnants disappeared progressively. One had heavy hemorrhage. Laparotomy was performed and the lesion was excised. Analysis of all these women's hysterocopy characteristics revealed that four successfully treated women had intrauterine gestational sacs. One who had experienced heavy hemorrhage and laparotomy were with deep sac implantation. Conclusions:Suction curettage is a feasible conservative procedure for cases that had intrauterine gestational sacs. Hysteroscopy are useful for screening suitable cases and guiding the procedure.%目的:探讨清宫术治疗剖宫产瘢痕妊娠的指征。方法:对2007—2009年在我院诊断剖宫产瘢痕妊娠、给予宫腔镜辅助清宫术治疗的患者7例进行回顾性分析,评价临床资料、B超检查、宫腔镜表现与治疗效果的关系。结果:4例患者用清宫术治愈,出血不多:2例清宫不全、补充药物治疗(MTX)后治愈;1例清宫术中出血多、急诊开腹手术行病灶切除术。成功治疗的患者宫腔镜检查表现为孕囊凸向腔内,而出血多、治疗失败的患者孕囊植入深。结论:对妊娠物凸向宫腔内的剖宫产瘢痕妊娠,清宫术是有效、简便的治疗方法,宫腔镜有利于筛选合适病例。

  13. Flexible Thermoelectric Generators on Silicon Fabric

    KAUST Repository

    Sevilla, Galo T.

    2012-01-01

    In this work, the development of a Thermoelectric Generator on Flexible Silicon Fabric is explored to extend silicon electronics for flexible platforms. Low cost, easily deployable plastic based flexible electronics are of great interest for smart

  14. The Flexibility of Organization and the flexibility of product – premises of organizational success

    OpenAIRE

    Todorut, Amalia Venera

    2008-01-01

    Flexibility represents the ability of a manufactural system to adapt to some diversified tasks of production, thus to assure an economic efficiency – the rapport time/cost should be optimum, with insignificant structure changes within a long period of time. The central role of flexibility is to permit the survival and the success of the organizations in a turbulent circumstance, which is characteristic to the new world tendencies. The more flexible the organization becomes, the better it resp...

  15. Contagious flexibility? A study on whether schedule flexibility facilitates work-life enrichment.

    Science.gov (United States)

    Pedersen, Vivi Bach; Jeppesen, Hans Jeppe

    2012-08-01

    Schedule flexibility defines an important generating resource for work-life enrichment; however, our knowledge about how such spillovers take place is limited. This multiple case study examines how workers from different working time contexts with varying levels of schedule flexibility experience work-life interplay. Given the adopted explorative design, it is important to interpret the findings in a tentative light. Nonetheless, the study offers important insight into work-life enrichment that may guide future research in this field. The findings indicate that schedule flexibility may act as a boundary-spanning resource owing to the agency potential it offers workers. Thus, it seemed that flexible schedule opportunities enabled workers to engage more fully in personal life activities, which in turn had a positive influence on their work involvement through positive affect. Such positive role engagements appeared, however, to be greatly determined by workers' boundary management and by time conditions of work and family. In conclusion, the major findings and limitation of the study are discussed against existing research and theory. © 2012 The Authors. Scandinavian Journal of Psychology © 2012 The Scandinavian Psychological Associations.

  16. Influence of fluid viscosity on vortex cavitation at a suction pipe inlet

    International Nuclear Information System (INIS)

    Ezure, Toshiki; Ito, Kei; Kamide, Hideki; Kameyama, Yuri; Kunugi, Tomoaki

    2016-01-01

    Cavitation is a highly important issue in various fluid machineries. In the design of an advanced loop-type sodium-cooled fast reactor in Japan, vortex cavitation is also a significant issue for the integrity of the reactor structure. Thus, an evaluation method for vortex cavitation is required. In this study, vortex cavitation at a single suction pipe inlet was studied under several different viscosity conditions including its transient behavior. The intermittent occurrence behaviors of vortex cavitation were grasped by visualization measurements. The experimental results showed that the influence of the kinematic viscosity was obvious under a high kinematic viscosity. However, the influence became smaller with decreasing kinematic viscosity. From these results, the non-dimensional circulation, which was defined as the ratio of the local circulation to the kinematic viscosity, was deduced as an evaluation parameter to estimate the influence of the kinematic viscosity. Cavitation factors at transition points from continuous occurrence to intermittent occurrences were also evaluated as representative points where vortex cavitation occurs. Then, the occurrences of vortex cavitation were expressed as a relation between the cavitation factor at transition points and the non-dimensional circulation. As a result, it was clarified that the cavitation factor at transition points increased linearly in relatively small non-dimensional circulation, while it was nearly constant in relatively large non-dimensional circulation. (author)

  17. On the Evaluation of Failure Probability on Monolithic Vertical Wall Breakwaters

    DEFF Research Database (Denmark)

    Burcharth, H. F.; Sørensen, Jørgen S.; Christiani, E.

    1994-01-01

    The paper presents a level II, FORM-evaluation of the reliability against sliding of a caisson breakwater. Further, a reliability-based optimal design procedure for breakwaters exposed to multifailure mode is discussed.......The paper presents a level II, FORM-evaluation of the reliability against sliding of a caisson breakwater. Further, a reliability-based optimal design procedure for breakwaters exposed to multifailure mode is discussed....

  18. A biorobotic model of the suction-feeding system in largemouth bass: the roles of motor program speed and hyoid kinematics.

    Science.gov (United States)

    Kenaley, Christopher P; Lauder, George V

    2016-07-01

    The vast majority of ray-finned fishes capture prey through suction feeding. The basis of this behavior is the generation of subambient pressure through rapid expansion of a highly kinetic skull. Over the last four decades, results from in vivo experiments have elucidated the general relationships between morphological parameters and subambient pressure generation. Until now, however, researchers have been unable to tease apart the discrete contributions of, and complex relationships among, the musculoskeletal elements that support buccal expansion. Fortunately, over the last decade, biorobotic models have gained a foothold in comparative research and show great promise in addressing long-standing questions in vertebrate biomechanics. In this paper, we present BassBot, a biorobotic model of the head of the largemouth bass (Micropterus salmoides). BassBot incorporates a 3D acrylic plastic armature of the neurocranium, maxillary apparatus, lower jaw, hyoid, suspensorium and opercular apparatus. Programming of linear motors permits precise reproduction of live kinematic behaviors including hyoid depression and rotation, premaxillary protrusion, and lateral expansion of the suspensoria. BassBot reproduced faithful kinematic and pressure dynamics relative to live bass. We show that motor program speed has a direct relationship to subambient pressure generation. Like vertebrate muscle, the linear motors that powered kinematics were able to produce larger magnitudes of force at slower velocities and, thus, were able to accelerate linkages more quickly and generate larger magnitudes of subambient pressure. In addition, we demonstrate that disrupting the kinematic behavior of the hyoid interferes with the anterior-to-posterior expansion gradient. This resulted in a significant reduction in subambient pressure generation and pressure impulse of 51% and 64%, respectively. These results reveal the promise biorobotic models have for isolating individual parameters and assessing

  19. Effect of Zr Purity and Oxygen Content on the Structure and Mechanical Properties of Melt-Spun and Suction-Cast Cu46Zr42Al7Y5 Alloy

    Directory of Open Access Journals (Sweden)

    Kozieł T.

    2016-06-01

    Full Text Available The effect of oxygen content in zirconium on the structure and mechanical properties of the Cu46Zr42Al7Y5 alloy, in the form of melt-spun ribbons and suction-cast rods, was investigated. Two types of Zr, rod and crystal bar of different nominal purities and oxygen contents, were used to synthesize the alloy by arc melting. Rapidly solidified ribbons were produced by melt spinning and their amorphous structures were confirmed by X-ray diffractometry (XRD and differential scanning calorimetry (DSC. Bulk samples in the form of rods were cast using a special water-cooled suction casting unit attached to the arc melting system. XRD and DSC studies proved the amorphous structure of the bulk alloy synthesized from low-oxygen Zr and partial crystallization of the same alloy for high-oxygen Zr. In both bulk samples, uniformly distributed crystalline particles were identified as yttrium oxides. Higher mean compressive strength of amorphous alloy was observed. The hardness of amorphous phase was close to 500 HV1 in both bulk alloys, while the hardness of crystalline dendritic areas, observed in the alloy synthesized from high oxygen Zr, was lower by about 50 HV1.

  20. UNITY OF THE ORGANIZATIONAL FUNCTIONS FLEXIBILITY

    OpenAIRE

    George MOLDOVEANU; Cosmin DOBRIN

    2012-01-01

    The paper has the goal to analyse the correlation of the flexibility of all organizational functions. Based upon theoretical and practical studies, the decrease of flexibility into an "activity area" of organizations implies a diminution on a large scale of the flexibility of the processing system as a law expression of the decreasing outputs within economy. Therefore, at the level of each organizational function there are several major directions ensuring the flexibility of the "ensemble".