WorldWideScience

Sample records for flash x-ray radiography

  1. Review of low x-ray fluence detection developments on flash radiography

    Science.gov (United States)

    Cavailler, Claude

    1995-05-01

    Dealing with dynamic behavior of solids, flows, detonator initiation, high explosives properties, shock waves and other fast processes, implies a large amount of metrology problems. When studies on shock waves began, forty five years ago, only flash X-ray radiography achieving chronometric measurements was developed, in order to investigate shaped charges jets. This technique has also been widely used in detonics because it does not affect hydrodymanic phenomena. Since that time, a large amount of data has been gathered and has allowed physicists to confirm many theories. Later pulsed high energy radiographic machines emitting X-rays have allowed large images record of voluminous objects containing dense materials (with high atomic numbers) and therefore very absorbing. Our laboratory has been working in this field for more than 30 years. A great deal of effort has been spent to enhance the radiographic capabilities of our X-ray machines. High dose levels and better spot size diameter of X-ray sources have allowed quite good records for a better understanding on material densities and boundaries. During the same period of time many works were led on the detection of low X-ray fluences. We present in this communication the main studies developed in that field on cells of light screens coupled with visible film and on microchannel plates image intensifiers.

  2. Application of GaAs and CdTe photoconductor detectors to X-ray flash radiography

    Energy Technology Data Exchange (ETDEWEB)

    Mathy, F.; Cuzin, M.; Gagelin, J.J.; Mermet, R.; Piaget, B.; Rustique, J.; Verger, L. (CEA, Direction des Technologies Avancees, Lab. d' Electronique, de Technologie et d' Instrumentation, DSYS, 38 - Grenoble (France)); Hauducoeur, A.; Nicolas, P.; Le Dain, L.; Hyvernage, M. (CEA, Direction des Applications Militaires, 77 - Courtry (France))

    1992-11-15

    Some insulating GaAs and CdTe:Cl photoconductor probes were qualified on high energy X-ray single-shot flash generators. The estimated minimum detected dose per flash corresponding to a 230 mrad direct beam attenuated by 200 mm lead was 20 [mu]rad. The dynamic range was about 4 decades in amplitude or charge, with a good linearity. Such detectors, by locating the origin of the parasitic scattered beam, could be used to eliminate this parasitic beam in X-ray flash radiography in detonics experiments. Imaging possibilities are mentioned, as well as X-ray generator monitoring with such detectors or with neutron preirradiated photoconductors. (orig.).

  3. Application of GaAs and CdTe photoconductor detectors to x-ray flash radiography

    Energy Technology Data Exchange (ETDEWEB)

    Mathy, F.; Cuzin, M.; Gagelin, J.J.; Mermet, R.; Piaget, B.; Rustique, J.; Verger, L. [CEA Centre d`Etudes de Grenoble, 38 (FR). Direction des Technologies Avancees; Hauducoeur, A.; Nicolas, P.; Le Dain, L.; Hyvernage, M. [CEA Centre d`Etudes de Vaujours, 77 - Courtry (FR)

    1991-12-31

    Semi-insulating GaAs and CdTe:Cl photoconductor probes were qualified on high energy X ray single shot flash generators. The estimated minimum detected dose per flash corresponding to a 230 mrad direct beam attenuated by 200 mm lead was 20 {mu}rad. The dynamic range was about 4 decades in amplitude or charges, with a good linearity. Such detectors, by locating the origin of the parasitic scattered beam, could be used to eliminate this parasitic beam in X ray flash radiography in detonics experiments. Imaging possibilities are mentioned, as well as X ray generator monitoring with such detectors or with neutron preirradiated photoconductors.

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive medical ...

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) ... diagnosis and disease management. top of page How is the procedure performed? The technologist, an individual specially ...

  6. Design of a 7-MV Linear Transformer Driver (LTD) for down-hole flash x-ray radiography.

    Energy Technology Data Exchange (ETDEWEB)

    Cordova, Steve Ray; Welch, Dale Robert (Voss Scientific, Albuquerque, NM); Oliver, Bryan Velten; Rose, David Vincent (Voss Scientific, Albuquerque, NM); Johnson, David Lee (L-3 Communications - Pulse Sciences, San Leandro, CA); Bruner, Nichelle Lee (Voss Scientific, Albuquerque, NM); Leckbee, Joshua J.

    2008-09-01

    Pulsed power driven flash x-ray radiography is a valuable diagnostic for subcritical experiments at the Nevada Test Site. The existing dual-axis Cygnus system produces images using a 2.25 MV electron beam diode to produce intense x-rays from a small source. Future hydrodynamic experiments will likely use objects with higher areal mass, requiring increased x-ray dose and higher voltages while maintaining small source spot size. A linear transformer driver (LTD) is a compact pulsed power technology with applications ranging from pulsed power flash x-ray radiography to high current Z-pinch accelerators. This report describes the design of a 7-MV dual-axis system that occupies the same lab space as the Cygnus accelerators. The work builds on a design proposed in a previous report [1]. This new design provides increased diode voltage from a lower impedance accelerator to improve coupling to low impedance diodes such as the self magnetic pinch (SMP) diode. The design also improves the predicted reliability by operating at a lower charge voltage and removing components that have proven vulnerable to failure. Simulations of the new design and experimental results of the 1-MV prototype are presented.

  7. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Us News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses ... assess trauma patients in emergency departments. A CT scan can image complicated fractures, subtle fractures or dislocations. ...

  8. Abdomen X-Ray (Radiography)

    Science.gov (United States)

    ... Professions Site Index A-Z X-ray (Radiography) - Abdomen Abdominal x-ray uses a very small dose ... to produce pictures of the inside of the abdominal cavity. It is used to evaluate the stomach, liver, ...

  9. Demonstration of the self-magnetic-pinch diode as an X-ray source for flash core-punch radiography.

    Energy Technology Data Exchange (ETDEWEB)

    Cordova, Steve Ray; Rovang, Dean Curtis; Portillo, Salvador; Oliver, Bryan Velten; Bruner, Nichelle Lee (Voss Scientific, Albuquerque, NM); Ziska, Derek Raymond (K-Tech Corporation, Albuquerque, NM)

    2007-10-01

    Minimization of the radiographic spot size and maximization of the radiation dose is a continuing long-range goal for development of electron beam driven X-ray radiography sources. In collaboration with members of the Atomic Weapons Establishment(AWE), Aldermaston UK, the Advanced Radiographic Technologies Dept. 1645 is conducting research on the development of X-ray sources for flash core-punch radiography. The Hydrodynamics Dept. at AWE has defined a near term radiographic source requirement for scaled core-punch experiments to be 250 rads{at}m with a 2.75 mm source spot-size. As part of this collaborative effort, Dept. 1645 is investigating the potential of the Self-Magnetic-Pinched (SMP) diode as a source for core-punch radiography. Recent experiments conducted on the RITS-6 accelerator [1,2] demonstrated the potential of the SMP diode by meeting and exceeding the near term radiographic requirements established by AWE. During the demonstration experiments, RITS-6 was configured with a low-impedance (40 {Omega}) Magnetically Insulated Transmission Line (MITL), which provided a 75-ns, 180-kA, 7.5-MeV forward going electrical pulse to the diode. The use of a low-impedance MITL enabled greater power coupling to the SMP diode and thus allowed for increased radiation output. In addition to reconfiguring the driver (accelerator), geometric changes to the diode were also performed which allowed for an increase in dose production without sacrificing the time integrated spot characteristics. The combination of changes to both the pulsed power driver and the diode significantly increased the source x-ray intensity.

  10. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... holds the x-ray film or image recording plate . Sometimes the x-ray is taken with the ... an x-ray film holder or image recording plate is placed beneath the patient. top of page ...

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... holds the x-ray film or image recording plate . Sometimes the x-ray is taken with the ... an x-ray film holder or image recording plate is placed beneath the patient. top of page ...

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... drawer under the table holds the x-ray film or image recording plate . Sometimes the x-ray ... extended over the patient while an x-ray film holder or image recording plate is placed beneath ...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... that might interfere with the x-ray images. Women should always inform their physician and x-ray ... Safety page for more information about radiation dose. Women should always inform their physician or x-ray ...

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the body. X-rays are the oldest and most frequently used form of medical imaging. A bone ... bones. top of page How should I prepare? Most bone x-rays require no special preparation. You ...

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... tissue shows up in shades of gray and air appears black. Until recently, x-ray images were ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? A bone x-ray is used to: ... and x-rays. top of page What does the equipment look like? The equipment typically used for ...

  17. Bone X-Ray (Radiography)

    Science.gov (United States)

    ... clothing that might interfere with the x-ray images. Women should always inform their physician and x-ray ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different ...

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures ...

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... patient. top of page How does the procedure work? X-rays are a form of radiation like ... very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures that ...

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... radiation like light or radio waves. X-rays pass through most objects, including the body. Once it ... organs, allow more of the x-rays to pass through them. As a result, bones appear white ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... and x-rays. A Word About Minimizing Radiation Exposure Special care is taken during x-ray examinations ... patient's body not being imaged receive minimal radiation exposure. top of page What are the limitations of ...

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... fracture. guide orthopedic surgery, such as spine repair/fusion, joint replacement and fracture reductions. look for injury, ... and Media Arthritis X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to X-ray ( ...

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? A bone x-ray is used to: ... and x-rays. top of page What does the equipment look like? The equipment typically used for ...

  6. Upper Gastrointestinal (GI) Tract X-Ray (Radiography)

    Science.gov (United States)

    ... Site Index A-Z X-ray (Radiography) - Upper GI Tract Upper gastrointestinal tract radiography or upper GI ... GI) Tract X-ray? What is Upper Gastrointestinal (GI) Tract Radiography? Upper gastrointestinal tract radiography, also called ...

  7. Lower Gastrointestinal (GI) Tract X-Ray (Radiography)

    Science.gov (United States)

    ... Site Index A-Z X-ray (Radiography) - Lower GI Tract Lower gastrointestinal tract radiography or lower GI ... of Lower GI Tract Radiography? What is Lower GI Tract X-ray Radiography (Barium Enema)? Lower gastrointestinal ( ...

  8. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... clothing that might interfere with the x-ray images. Women should always inform their physician and x-ray ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different ...

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... bone absorbs much of the radiation while soft tissue, such as muscle, fat and organs, allow more of the x-rays to pass through them. As a result, bones appear white on the x-ray, soft tissue shows up in shades of gray and air ...

  10. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... during x-ray examinations to use the lowest radiation dose possible while producing the best images for evaluation. National and international radiology protection organizations continually review ...

  11. Bone X-Ray (Radiography)

    Science.gov (United States)

    ... bony fragments following treatment of a fracture. guide orthopedic surgery, such as spine repair/fusion, joint replacement ... A portable x-ray machine is a compact apparatus that can be taken to the patient in ...

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the oldest and most frequently used form of medical imaging. A bone x-ray makes images of any ... a radiologist or other physician. To locate a medical imaging or radiation oncology provider in your community, you ...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... replacement and fracture reductions. look for injury, infection, arthritis , abnormal bone growths and bony changes seen in ... injuries, including fractures, and joint abnormalities, such as arthritis. X-ray equipment is relatively inexpensive and widely ...

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Bone x-rays are the fastest and ... in the typical diagnostic range for this exam. Risks There is always a slight chance of cancer ...

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... asked to wait until the radiologist determines that all the necessary images have been obtained. A bone ... while it may be barely seen, if at all, on a hip x-ray. For suspected spine ...

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... patients and physicians. Because x-ray imaging is fast and easy, it is particularly useful in emergency ... diagnosis and treatment of the individual patient's condition. Ultrasound imaging, which uses sound waves instead of ionizing ...

  17. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... a form of radiation like light or radio waves. X-rays pass through most objects, including the ... individual patient's condition. Ultrasound imaging, which uses sound waves instead of ionizing radiation to create diagnostic images, ...

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... pregnant. Many imaging tests are not performed during pregnancy so as not to expose the fetus to ... See the Safety page for more information about pregnancy and x-rays. top of page What does ...

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... are easily accessible and are frequently compared to current x-ray images for diagnosis and disease management. ... of North America, Inc. (RSNA). To help ensure current and accurate information, we do not permit copying ...

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... ionizing radiation to produce pictures of any bone in the body. It is commonly used to diagnose ... bone x-ray makes images of any bone in the body, including the hand, wrist, arm, elbow, ...

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... examination may also be necessary so that any change in a known abnormality can be monitored over ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... patients and physicians. Because x-ray imaging is fast and easy, it is particularly useful in emergency ... 06, 2016 Send us your feedback Did you find the information you were looking for? Yes No ...

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... in emergency rooms, physician offices, ambulatory care centers, nursing homes and other locations, making it convenient for ... Safety page for more information about radiation dose. Women should always inform their physician or x-ray ...

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... evaluation with additional views or a special imaging technique. A follow-up examination may also be necessary ... radiology protection organizations continually review and update the technique standards used by radiology professionals. Modern x-ray ...

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... x-ray images were maintained on large film sheets (much like a large photographic negative). Today, most ... accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, ...

  6. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... x-ray machine is a compact apparatus that can be taken to the patient in a hospital ... so that any change in a known abnormality can be monitored over time. Follow-up examinations are ...

  7. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... in a known abnormality can be monitored over time. Follow-up examinations are sometimes the best way ...

  8. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... for more information about pregnancy and x-rays. A Word About Minimizing Radiation Exposure Special care is ... code: Phone no: Thank you! Do you have a personal story about radiology? Share your patient story ...

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2017 Radiological ...

  10. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different ... This ensures that those parts of a patient's body not being imaged receive minimal radiation ... x-ray images are among the clearest, most detailed views of ...

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... for more information about pregnancy and x-rays. A Word About Minimizing Radiation Exposure Special care is ... encourage linking to this site. × Recommend RadiologyInfo to a friend Send to (friend's e-mail address): From ( ...

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z X-ray ( ... are the fastest and easiest way for your doctor to view and assess bone fractures, injuries and ...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... and places the x-ray film holder or digital recording plate under the table in the area of the body being imaged. When necessary, sandbags, pillows or other positioning devices will be used to help you maintain the ...

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... An x-ray (radiograph) is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... for more information about pregnancy and x-rays. A Word About Minimizing Radiation Exposure Special care is ... encourage linking to this site. × Recommend RadiologyInfo to a friend Send to (friend's e-mail address): From ( ...

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... dislocations. In elderly or patients with osteoporosis, a hip fracture may be clearly seen on a CT scan, while it may be barely seen, if at all, on a hip x-ray. For suspected spine injury or other ...

  17. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... An x-ray (radiograph) is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  18. Development of cable fed flash X-ray (FXR) system

    Science.gov (United States)

    Menon, Rakhee; Mitra, S.; Patel, A. S.; Kumar, R.; Singh, G.; Senthil, K.; Kumar, Ranjeet; Kolge, T. S.; Roy, Amitava; Acharya, S.; Biswas, D.; Sharma, Archana

    2017-08-01

    Flash X-ray sources driven by pulsed power find applications in industrial radiography, and a portable X-ray source is ideal where the radiography needs to be taken at the test site. A compact and portable flash X-ray (FXR) system based on a Marx generator has been developed with the high voltage fed to the FXR tube via a cable feed-through arrangement. Hard bremsstrahlung X-rays of few tens of nanosecond duration are generated by impinging intense electron beams on an anode target of high Z material. An industrial X-ray source is developed with source size as low as 1 mm. The system can be operated from 150 kV to 450 kV peak voltages and a dose of 10 mR has been measured at 1 m distance from the source window. The modeling of the FXR source has been carried out using particle-in-cell and Monte Carlo simulations for the electron beam dynamics and X-ray generation, respectively. The angular dose profile of X-ray has been measured and compared with the simulation.

  19. Chest X-Ray (Chest Radiography)

    Science.gov (United States)

    ... clothing that might interfere with the x-ray images. Women should always inform their physician and x-ray ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different ...

  20. Low-photon-energy plasma flash x-ray generator (LPFXG-2002)

    Science.gov (United States)

    Komatsu, Makoto; Sato, Eiichi; Hayasi, Yasuomi; Usuki, Tatsumi; Sato, Koetsu; Tanaka, Etsuro; Mori, Hidezo; Ojima, Hidenori; Takayama, Kazuyoshi; Ido, Hideaki

    2003-07-01

    In this study, we have made a low photon energy flash x-ray generator with a titanium target and have measured the radiographic characteristics. The flash x-ray generator consists of a high-voltage power supply, a high-voltage condenser, a turbo molecular pump and a flash x-ray tube. The condenser is charged up to about 30 kV, and the electric charges in the condenser are discharged to the tube after triggering the cathode. The linear plasma x-ray source forms from the target evaporation, and then the flash x-rays are generated from the plasma in the axial direction. K-series emission of titanium has been confirmed in experiments qualitatively and characteristics of the generator have been measured. K-series x-ray of titanium had a high resolution and enable us to take radiographs of a thin rabbit's ear clearly using the CR (Computed Radiography) system. The effect of titanium on the target of the soft flash x-ray tube has been indicated accordingly.

  1. X-ray image quality in radiography

    Energy Technology Data Exchange (ETDEWEB)

    Borcke, E.

    1987-01-01

    A proposal is worked out to express X-ray image quality by means of a meaningful and practically useful numerical system. Attenuations have been selected in such a manner that whole numbers of quality value figures ranging from -10 to +60 result in meaningful associations with radiological indications. Individual parameters are incorporated into the resulting values. A test body for determining information sensitivity figures is described that is practical easy built and inexpensive; its most important feature, however, is that it is reproducible and permits international comparisons. This test body provides a direct linking with the quality value figures.

  2. Miniature, mobile X-ray computed radiography system

    Energy Technology Data Exchange (ETDEWEB)

    Watson, Scott A; Rose, Evan A

    2017-03-07

    A miniature, portable x-ray system may be configured to scan images stored on a phosphor. A flash circuit may be configured to project red light onto a phosphor and receive blue light from the phosphor. A digital monochrome camera may be configured to receive the blue light to capture an article near the phosphor.

  3. X-ray Flashes from Off-axis Nonuniform Jets

    Institute of Scientific and Technical Information of China (English)

    Zhi-Ping Jin; Da-Ming Wei

    2004-01-01

    It has been widely believed that the outflows in gamma-ray bursts are jetted and some jets may have structures like ∈(θ) ∝θ-κ. We check the possibility that X-ray flashes come from such jets. Both qualitative and quantitative analyses have shown that this model can reproduce most of the observational features of both X-ray flashes and gamma-ray bursts. Using the usual parameters of gamma-ray bursts, we have carried out numerical calculations for both uniform and nonuniform jets, of their fluxes, spectra and peak energies. It seems that nonuniform jets are more appropriate to these observational properties than uniform jets. We have also shown that in our model the observational ratio of gamma-ray bursts to X-ray flashes is about a few units.

  4. High spectral and spatial resolution X-ray transmission radiography and tomography using a Color X-ray Camera

    OpenAIRE

    Boone, Matthieu; Garrevoet, Jan; Tack, Pieter; Scharf, Oliver; Cormode, David P.; Van Loo, Denis; Pauwels, Elin; Dierick, Manuel; Vincze, Laszlo; Van Hoorebeke, Luc

    2013-01-01

    High resolution X-ray radiography and computed tomography are excellent techniques for non-destructive characterization of an object under investigation at a spatial resolution in the micrometer range. However, as the image contrast depends on both chemical composition and material density, no chemical information is obtained from this data. Furthermore, lab-based measurements are affected by the polychromatic X-ray beam, which results in beam hardening effects. New types of X-ray detectors w...

  5. Measuring x-ray spectra of flash radiographic sources

    Science.gov (United States)

    Gehring, Amanda E.; Espy, Michelle A.; Haines, Todd J.; Mendez, Jacob; Moir, David C.; Sedillo, Robert; Shurter, Roger P.; Volegov, Petr; Webb, Timothy J.

    2015-08-01

    A Compton spectrometer has been re-commissioned for measurements of flash radiographic sources. The determination of the energy spectrum of these sources is difficult due to the high count rates and short nature of the pulses (~50 ns). The spectrometer is a 300 kg neodymium-iron magnet which measures spectra in the <1 MeV to 20 MeV energy range. Incoming x-rays are collimated into a narrow beam incident on a converter foil. The ejected Compton electrons are collimated so that the forward-directed electrons enter the magnetic field region of the spectrometer. The position of the electrons at the magnet's focal plane is a function of their momentum, allowing the x-ray spectrum to be reconstructed. Recent measurements of flash sources are presented.

  6. Analysis of sculptures using XRF and X-ray radiography

    Science.gov (United States)

    Calza, C.; Oliveira, D. F.; Freitas, R. P.; Rocha, H. S.; Nascimento, J. R.; Lopes, R. T.

    2015-11-01

    This work reports the analysis of two sacred images on polychrome wood using X-ray Radiography and Energy Dispersive X-Ray Fluorescence. The first case is the analysis of a sculpture portraying Saint Sebastian, the patron saint of Rio de Janeiro, which is considered the second most ancient sacred image of Brazil. This sculpture was made in Portugal and was transported to Brazil by Estácio Sá, founder of the city of Rio de Janeiro, in 1565. Nowadays, it is located on the main altar of the Church of Capuchin Friars. The second case is the analysis of a sculpture representing Our Lady of Conception, which is located in the D. João VI Museum (EBA/UFRJ, Rio de Janeiro). The objective of these analyses was to evaluate the general conditions of the sculptures, identifying possible problems and internal damages, areas that revealed signs of previous retouchings and the materials and pigments employed by the artists, in order to assist its restoration procedures. EDXRF measurements were carried out with a portable system, developed at the Nuclear Instrumentation Laboratory, consisting of a Si-PIN XR-100CR detector from Amptek and an Oxford TF3005 X-ray tube with W anode. An X-ray source, a CR System GE CR50P and IP detectors were used to perform the radiographs. The XRF analysis of the sculptures identified the original pigments in both cases and the radiographic images revealed details of the manufacture; restored regions; extensive use of lead white; presence of cracks on the wood; use of nails and spikes, etc.

  7. Portable energy dispersive X-ray fluorescence and X-ray diffraction and radiography system for archaeometry

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza Cuevas, Ariadna, E-mail: ariadna@mail.or [Archaeometry Laboratory, Colegio Universitario San Geronimo de La Habana, Obispo, entre San Ignacio y Mercaderes, Habana Vieja, cp 10 100, Havana (Cuba); Perez Gravie, Homero, E-mail: homero.perezgravie@mail.co [Archaeometry Laboratory, Colegio Universitario San Geronimo de La Habana, Obispo, entre San Ignacio y Mercaderes, Habana Vieja, cp 10 100, Havana (Cuba)

    2011-03-21

    Starting on a laboratory developed portable X-ray fluorescence (PXRF) spectrometer; three different analytical results can be performed: analysis of chemical elements, analysis of major chemical crystalline phase and structural analysis, which represents a contribution to a new, low cost development of portable X-ray analyzer; since these results are respectively obtained with independent equipments for X-ray fluorescence, X-ray diffraction and radiography. Detection limits of PXRF were characterized using standard reference materials for ceramics, glass, bronze and bones, which are the main materials requiring quantitative analysis in art and archeological objects. A setup for simultaneous energy dispersive X-ray fluorescence and diffraction (ED (XRF-XRD)) in the reflection mode has been tested for in situ and non-destructive analysis according to the requirements of art objects inspection. The system uses a single low power X-ray tube and an X-ray energy dispersive detector to measure X-ray diffraction spectrum at a fixed angle. Application to the identification of jadeite-jade mineral in archeological objects by XRD is presented. A local high resolution radiography image obtained with the same low power X-ray tube allows for studies in painting and archeological bones.

  8. X-ray flashes in ROSAT PSPC data

    Energy Technology Data Exchange (ETDEWEB)

    Sun, X.; Li, H.; Fenimore, E.E. [Los Alamos National Lab., NM (United States); Wang, Q.D. [Northwestern Univ., Evanston, IL (United States)

    1998-12-01

    The authors find 24 short (200--2,500s) X-ray flashes from all the ROSAT Position Sensitive Proportional Counter (PSPC) observations above galactic latitude 30 degrees ({approximately} 9.6 Msec) and some observations toward low latitudes ({approximately} 2.4 Msec). The brightest flash is quite extraordinary. Its flux rises from nondetection by a factor of > 200 in less than 100 sec. Its spectrum can be fitted either by a thermal plasma model with kT {ge} 2.4 keV, or by a single power-law with the photon number index of {approx} {minus}1.7. Photon statistics are not sufficient to obtain spectra for other flashes. The flash event fields can vary from optically crowded regions to blank fields. Although eight flashes are found from observations from nearby galaxies, and three of them are within the optical extent of their corresponding galaxies, they could not statistically establish that there are two different populations between nearby galaxies and control fields.

  9. High spectral and spatial resolution X-ray transmission radiography and tomography using a Color X-ray Camera

    Energy Technology Data Exchange (ETDEWEB)

    Boone, Matthieu N., E-mail: matthieu.boone@ugent.be [Ghent University, Department of Physics and Astronomy, Proeftuinstraat 86, B-9000 Gent (Belgium); Garrevoet, Jan; Tack, Pieter [Ghent University, Department of Analytical Chemistry, Krijgslaan 281/S12, B-9000 Gent (Belgium); Scharf, Oliver [IfG-Institute for Scientific Instruments GmbH, Rudower Chaussee 29/31, D-12489 Berlin (Germany); Cormode, David P. [University of Pennsylvania, Departments of Radiology, Cardiology and Bioengineering, O3400 Spruce St, 1 Silverstein, Philadelphia, PA 19104 (United States); Van Loo, Denis; Pauwels, Elin; Dierick, Manuel [Ghent University, Department of Physics and Astronomy, Proeftuinstraat 86, B-9000 Gent (Belgium); Vincze, Laszlo [Ghent University, Department of Analytical Chemistry, Krijgslaan 281/S12, B-9000 Gent (Belgium); Van Hoorebeke, Luc [Ghent University, Department of Physics and Astronomy, Proeftuinstraat 86, B-9000 Gent (Belgium)

    2014-01-21

    High resolution X-ray radiography and computed tomography are excellent techniques for non-destructive characterization of an object under investigation at a spatial resolution in the micrometer range. However, as the image contrast depends on both chemical composition and material density, no chemical information is obtained from this data. Furthermore, lab-based measurements are affected by the polychromatic X-ray beam, which results in beam hardening effects. New types of X-ray detectors which provide spectral information on the measured X-ray beam can help to overcome these limitations. In this paper, an energy dispersive CCD detector with high spectral resolution is characterized for use in high resolution radiography and tomography, where a focus is put on the experimental conditions and requirements of both measurement techniques.

  10. [Questions that radiography students have regarding X-ray photography: a qualitative study].

    Science.gov (United States)

    Terashita, Takayoshi; Kisa, Kengo; Oshima, Sumiko; Kawabata, Hidenobu

    2012-01-01

    To improve lectures and training programs on X-ray photography, we aimed to determine the questions that radiography students have regarding X-ray photography. We collected text data from questions on X-ray photography in radiography student reports after an X-ray photography training program. The text data were analyzed using content analysis. Codes were assigned to segments and they were categorized according to similarities. From 111 reports, 348 questions were collected. Four categories and 47 subcategories were obtained. The "Required Knowledge" category comprised subcategories concerning knowledge for the X-ray photography including X-ray radiography methodology and disease knowledge. The "Radiography Service" category comprised subcategories concerning radiographers' responsibilities in a hospital including the role of radiographer and the extent of responsibilities. The "Radiographers' Challenges" category comprised subcategories concerning unusual situations radiographers encounter at work including accurate positioning and communication with patients. The "Patient Types" category comprised subcategories concerning patients in whom X-ray photography was considered difficult including pediatric patients and patients with serious conditions. Questions related to subcategories in "Radiographers' Challenges" and "Patient Types" were interrelated. Radiography students had concerns regarding whether they would be able to handle difficult patients efficiently in clinical situations. We were able to suggest the re-orientation of radiography education according to students' intellectual appetite regarding X-ray radiography.

  11. An intraoral miniature x-ray tube based on carbon nanotubes for dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Jin; Kim, Hyun Nam; Raza, Hamid Saeed; Park, Han Beom; Cho, Sung Oh [Dept. of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2016-06-15

    A miniature X-ray tube based on a carbon-nanotube electron emitter has been employed for the application to a dental radiography. The miniature X-ray tube has an outer diameter of 7 mm and a length of 47 mm. The miniature X-ray tube is operated in a negative high-voltage mode in which the X-ray target is electrically grounded. In addition, X-rays are generated only to the teeth directions using a collimator while X-rays generated to other directions are shielded. Hence, the X-ray tube can be safely inserted into a human mouth. Using the intra-oral X-ray tube, a dental radiography is demonstrated where the positions of an X-ray source and a sensor are reversed compared with a conventional dental radiography system. X-ray images of five neighboring teeth are obtained and, furthermore, both left and right molar images are achieved by a single X-ray shot of the miniature X-ray tube.

  12. A miniature X-ray tube based on carbon nanotube for an intraoral dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Jin; Park, Han Beom; Lee, Ju Hyuk; Cho, Sung Oh [KAIST, Daejeon (Korea, Republic of)

    2016-05-15

    The number of human teeth that can be radiographically taken is limited. Moreover, at least two X-ray shots are required to get images of teeth from both sides of the mouth. In order to overcome the disadvantages of conventional dental radiography, a dental radiograph has been proposed in which an X-ray tube is inserted into the mouth while an X-ray detector is placed outside the mouth. The miniature X-ray tube is required small size to insert into the mouth. Recently, we have fabricated a miniature x-ray tube with the diameter of 7 mm using a carbon nanotube (CNT) field. But, commercialized miniature X-ray tube were adopted a thermionic type using tungsten filament. The X-ray tubes adopted thermionic emission has a disadvantage of increasing temperature of x-ray tube. So it need to cooling system to cool x-ray tube. On the other hands, X-ray tubes adopted CNT field emitters don't need cooling systems because electrons are emitted from CNT by applying high voltage without heating. We have developed the miniature x-ray tube that produce x-ray with uniform spatial distribution based on carbon nanotube field emitters. The fabricated miniature x-ray tube can be stably and reliably operated at 50kV without any vacuum pump. The developed miniature X-ray tube was applied for intraoral dental radiography that employs an intra-oral CNT-based miniature X-ray tube and extra-oral X-ray detectors. An X-ray image of many teeth was successfully obtained by a single X-ray shot using the intra-oral miniature X-ray tube system. Furthermore, images of both molar teeth of pig were simultaneously obtained by a single X-ray shot. These results show that the intraoral dental radiography, which employs an intraoral miniature X-ray tube and an extraoral X-ray detector, performs better than conventional dental radiography.

  13. Interpretation of Core Length in Shear Coaxial Rocket Injectors from X-ray Radiography Measurements

    Science.gov (United States)

    2014-06-01

    Shear Coaxial Rocket Injectors from X-ray Radiography Measurements 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT...ASME/SAE/ASEE Joint Propulsion Conference, Cleveland, OH, 28-30 July, 2014. PA#14340 14. ABSTRACT Shear coaxial injectors are so named because they...Length in Shear Coaxial Rocket Injectors from X-ray Radiography Measurements S. Alexander Schumaker1, Stephen A. Danczyk2 and Malissa D.A. Lightfoot2

  14. Infrared Radiography: Modeling X-ray Imaging without Harmful Radiation

    Science.gov (United States)

    Zietz, Otto; Mylott, Elliot; Widenhorn, Ralf

    2015-01-01

    Planar x-ray imaging is a ubiquitous diagnostic tool and is routinely performed to diagnose conditions as varied as bone fractures and pneumonia. The underlying principle is that the varying attenuation coefficients of air, water, tissue, bone, or metal implants within the body result in non-uniform transmission of x-ray radiation. Through the…

  15. Infrared Radiography: Modeling X-ray Imaging without Harmful Radiation

    Science.gov (United States)

    Zietz, Otto; Mylott, Elliot; Widenhorn, Ralf

    2015-01-01

    Planar x-ray imaging is a ubiquitous diagnostic tool and is routinely performed to diagnose conditions as varied as bone fractures and pneumonia. The underlying principle is that the varying attenuation coefficients of air, water, tissue, bone, or metal implants within the body result in non-uniform transmission of x-ray radiation. Through the…

  16. Spectral reconstruction of the flash X-ray generated by Dragon-I LIA based on transmission measurements

    Institute of Scientific and Technical Information of China (English)

    曹靖; 肖睿; 陈楠; 曹宏睿; 阴泽杰

    2015-01-01

    The Dragon-I linear induction accelerator (LIA) at China Academy of Engineering Physics generates 20 MeV flash X-rays mainly for radiography applications in fluid dynamics. Its spectral information is quite important for diagnostic X-ray imaging applications, but because of its short pulse and great radiation intensity, direct measurement is impossible. In this work, we propose a new method based on transmission measurements to obtain the flash X-ray spectrum. Pure iron cylinders were used as attenuation material, and alanine dosimeters were attached on their rear bottom to record the dose after different degrees of attenuation. Iterative least square method was used to unfold the spectrum, while Geant4 Monte Carlo code was used to simulate the X-ray spectrum. The unfolded spectrum and the simulated spectrum have a high degree of consistency, with the reduced chi-square value of 0.044. This shows that the method is reliable in estimating megavoltage high-intensity X-ray spectrum.

  17. Methodology of a numerical chain model for x-ray radiography

    Science.gov (United States)

    Christenson, Peggy; Snell, Charles; Devolder, Barbara; Yin, Lin; Kwan, Thomas; Mathews, Allen; Carlsten, Bruce

    2002-08-01

    The chain model for x-ray flash radiography (Ref. 1) developed at Los Alamos is an integrated simulation capability consisting of linked codes for the various physical processes that model an entire radiographic event. Two new features have been added to the computational chain model: (1) a link between accelerator and particle-in-cell codes, enabling accelerated electrons to be injected into a 2-D, relativistic, fully electromagnetic particle-in-cell (PIC) code and propagated to a bremsstrahlung converter target, and (2) a distribution-function capability to create electron sources from PIC simulations for use in Monte Carlo electron/photon transport calculations to produce synthetic radiographs. Physical variables of electrons from PIC calculations are binned to produce distribution functions, which can be randomly sampled to obtain source particles for Monte Carlo transport calculations through a bremsstrahlung converter target. Several methods of binning have been used to construct both correlated and uncorrelated distributions. We will present end-to-end simulations of the radiographic process in order to compare synthetic radiographs produced using several electron distribution functions and analog-like links. In addition, we studied the effects of different electron distributions on photon spectra, doses, and spot sizes produced from a converter target. Advantages and disadvantages of the different techniques will be discussed, and applications of the chain model will be presented. Ref. 1. T. Kwan, A. Mathews, P. Christenson, C. Snell, "Integrated system simulation in X-ray radiography", Computer Physics Communications 142, 263-269 (2001). Work supported by USDOE.

  18. Versatile compact X-ray radiography module for materials science under microgravity conditions

    Science.gov (United States)

    Kargl, F.; Balter, M.; Stenzel, Ch; Gruhl, Th; Daneke, N.; Meyer, A.

    2011-12-01

    A versatile compact microfocus X-ray radiography facility is presented. The facility serves as a technology demonstrator showing the applicability of X-ray radiography to experiments in space. It has been designed as an insert fully compatible with requirements of the Materials Science Laboratory aboard the International Space Station. The facility consists of a microfocus X-ray source delivering up to 20 W X-ray power at 100kV acceleration voltage and a 49.2×49.3mm RadEye2 sensor with a Scint-X scintillator at 48μm per pixel resolution with a 14bit dynamic range. The total device weight including sample chamber is 43 kg. The facility is classified as a fully protected radiography equipment according to German radiation safety laws. The capabilities of the facility for research in materials sciences are demonstrated in ground-based experiments.

  19. First experience with x-ray dark-field radiography for human chest imaging (Conference Presentation)

    Science.gov (United States)

    Noel, Peter B.; Willer, Konstantin; Fingerle, Alexander A.; Gromann, Lukas B.; De Marco, Fabio; Scherer, Kai H.; Herzen, Julia; Achterhold, Klaus; Gleich, Bernhard; Münzel, Daniela; Renz, Martin; Renger, Bernhard C.; Fischer, Florian; Braun, Christian; Auweter, Sigrid; Hellbach, Katharina; Reiser, Maximilian F.; Schröter, Tobias; Mohr, Jürgen; Yaroshenko, Andre; Maack, Hanns-Ingo; Pralow, Thomas; van der Heijden, Hendrik; Proksa, Roland; Köhler, Thomas; Wieberneit, Nataly; Rindt, Karsten; Rummeny, Ernst J.; Pfeiffer, Franz

    2017-03-01

    Purpose: To evaluate the performance of an experimental X-ray dark-field radiography system for chest imaging in humans and to compare with conventional diagnostic imaging. Materials and Methods: The study was institutional review board (IRB) approved. A single human cadaver (52 years, female, height: 173 cm, weight: 84 kg, chest circumference: 97 cm) was imaged within 24 hours post mortem on the experimental x-ray dark-field system. In addition, the cadaver was imaged on a clinical CT system to obtain a reference scan. The grating-based dark-field radiography setup was equipped with a set of three gratings to enable grating-based dark-field contrast x-ray imaging. The prototype operates at an acceleration voltage of up to 70 kVp and with a field-of-view large enough for clinical chest x-ray (>35 x 35 cm2). Results: It was feasible to extract x-ray dark-field signal of the whole human thorax, clearly demonstrating that human x-ray dark-field chest radiography is feasible. Lung tissue produced strong scattering, reflected in a pronounced x-ray dark-field signal. The ribcage and the backbone are less prominent than the lung but are also distinguishable. Finally, the soft tissue is not present in the dark-field radiography. The regions of the lungs affected by edema, as verified by CT, showed less dark-field signal compared to healthy lung tissue. Conclusion: Our results reveal the current status of translating dark-field imaging from a micro (small animal) scale to a macro (patient) scale. The performance of the experimental x-ray dark-field radiography setup offers, for the first time, obtaining multi-contrast chest x-ray images (attenuation and dark-field signal) from a human cadaver.

  20. "Real-Life" Pulse Flattening on the LLNL Flash X-ray (FXR) Machine

    Energy Technology Data Exchange (ETDEWEB)

    DeHope, W J; Jacob, J S; Kihara, R; Ong, M; Zentler, J M

    2007-06-25

    High-resolution radiography using high-current electron accelerators based on the linear induction accelerator principle requires the linac's final spot on the X-ray target to be millimeter-sized. The requisite final focusing solenoid is adjusted for a specific beam energy at its entrance, hence, temporal variation of entrance beam energy results in a less than optimal time-averaged spot size. The FXR (Flash X-Ray) induction linac facility at Lawrence Livermore National Laboratory will be briefly described with an emphasis on its pulsed power system. In principle, the pulsed Blumleins at the heart of the system output a square pulse when discharged at the peak of their charging waveform so that, with correct cell timing synchronization, the effective beam output into the final focusing solenoid should be optimally flat. We have found that real-life consideration of transmission line and pulse power details in both the injector and accelerator sections of the machine results in significant energy variations in the final beam. We have implemented methods of measurement and analysis that permits this situation to be quantified and improved upon. The improvement will be linked to final beam spot size and enhancement in expected radiographic resolution.

  1. Digital radiography can reduce scoliosis x-ray exposure

    Energy Technology Data Exchange (ETDEWEB)

    Kling, T.F. Jr.; Cohen, M.J.; Lindseth, R.E.; De Rosa, G.P. (Indiana Univ. School of Medicine, Indianapolis (USA))

    1990-09-01

    Digital radiology is a new computerized system of acquiring x-rays in a digital (electronic) format. It possesses a greatly expanded dose response curve that allows a very broad range of x-ray dose to produce a diagnostic image. Potential advantages include significantly reduced radiation exposure without loss of image quality, acquisition of images of constant density irrespective of under or over exposure, and reduced repeat rates for unsatisfactory films. The authors prospectively studied 30 adolescents with scoliosis who had both conventional (full dose) and digital (full, one-half, or one-third dose) x-rays. They found digital made AP and lateral image with all anatomic areas clearly depicted at full and one-half dose. Digital laterals were better at full dose and equal to conventional at one-half dose. Cobb angles were easily measured on all one-third dose AP and on 8 of 10 one-third dose digital laterals. Digital clearly depicted the Risser sign at one-half and one-third dose and the repeat rate was nil in this study, indicating digital compensates well for exposure errors. The study indicates that digital does allow radiation dose to be reduced by at least one-half in scoliosis patients and that it does have improved image quality with good contrast over a wide range of x-ray exposure.

  2. Shielded radiography with a laser-driven MeV-energy X-ray source

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Shouyuan; Golovin, Grigory [Department of Physics and Astronomy, University of Nebraska-Lincoln, Lincoln, NE 68588 (United States); Miller, Cameron [Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI 48109 (United States); Haden, Daniel; Banerjee, Sudeep; Zhang, Ping; Liu, Cheng; Zhang, Jun; Zhao, Baozhen [Department of Physics and Astronomy, University of Nebraska-Lincoln, Lincoln, NE 68588 (United States); Clarke, Shaun; Pozzi, Sara [Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI 48109 (United States); Umstadter, Donald, E-mail: donald.umstadter@unl.edu [Department of Physics and Astronomy, University of Nebraska-Lincoln, Lincoln, NE 68588 (United States)

    2016-01-01

    We report the results of experimental and numerical-simulation studies of shielded radiography using narrowband MeV-energy X-rays from a compact all-laser-driven inverse-Compton-scattering X-ray light source. This recently developed X-ray light source is based on a laser-wakefield accelerator with ultra-high-field gradient (GeV/cm). We demonstrate experimentally high-quality radiographic imaging (image contrast of 0.4 and signal-to-noise ratio of 2:1) of a target composed of 8-mm thick depleted uranium shielded by 80-mm thick steel, using a 6-MeV X-ray beam with a spread of 45% (FWHM) and 10{sup 7} photons in a single shot. The corresponding dose of the X-ray pulse measured in front of the target is ∼100 nGy/pulse. Simulations performed using the Monte-Carlo code MCNPX accurately reproduce the experimental results. These simulations also demonstrate that the narrow bandwidth of the Compton X-ray source operating at 6 and 9 MeV leads to a reduction of deposited dose as compared to broadband bremsstrahlung sources with the same end-point energy. The X-ray beam’s inherently low-divergence angle (∼mrad) is advantageous and effective for interrogation at standoff distance. These results demonstrate significant benefits of all-laser driven Compton X-rays for shielded radiography.

  3. Large area x-ray detectors for cargo radiography

    Science.gov (United States)

    Bueno, C.; Albagli, D.; Bendahan, J.; Castleberry, D.; Gordon, C.; Hopkins, F.; Ross, W.

    2007-04-01

    Large area x-ray detectors based on phosphors coupled to flat panel amorphous silicon diode technology offer significant advances for cargo radiologic imaging. Flat panel area detectors provide large object coverage offering high throughput inspections to meet the high flow rate of container commerce. These detectors provide excellent spatial resolution when needed, and enhanced SNR through low noise electronics. If the resolution is reduced through pixel binning, further advances in SNR are achievable. Extended exposure imaging and frame averaging enables improved x-ray penetration of ultra-thick objects, or "select-your-own" contrast sensitivity at a rate many times faster than LDAs. The areal coverage of flat panel technology provides inherent volumetric imaging with the appropriate scanning methods. Flat panel area detectors have flexible designs in terms of electronic control, scintillator selection, pixel pitch, and frame rates. Their cost is becoming more competitive as production ramps up for the healthcare, nondestructive testing (NDT), and homeland protection industries. Typically used medical and industrial polycrystalline phosphor materials such as Gd2O2S:Tb (GOS) can be applied to megavolt applications if the phosphor layer is sufficiently thick to enhance x-ray absorption, and if a metal radiator is used to augment the quantum detection efficiency and reduce x-ray scatter. Phosphor layers ranging from 0.2-mm to 1-mm can be "sandwiched" between amorphous silicon flat panel diode arrays and metal radiators. Metal plates consisting of W, Pb or Cu, with thicknesses ranging from 0.25-mm to well over 1-mm can be used by covering the entire area of the phosphor plate. In some combinations of high density metal and phosphor layers, the metal plate provides an intensification of 25% in signal due to electron emission from the plate and subsequent excitation within the phosphor material. This further improves the SNR of the system.

  4. Low Energy Plasma Focus as an Intense X-ray Source for Radiography

    Institute of Scientific and Technical Information of China (English)

    S. Hussain; M. Zakaullah; Shujaat Ali; A. Waheed

    2004-01-01

    Study on X-ray emission from a low energy (1.8 k J) plasma focus device powered by a 9 μF capacitor bank, charged at 20 kV and giving peak discharge current of about 175 kA by using a lead-inserted copper-tapered anode is reported. The X-ray yield in different energy windows is measured as a function of hydrogen filling pressure. The maximum yield in 4π-geometry is found to be (27.3±1.1) J and corresponding wall plug efficiency for X-ray generation is 1.52 ±0.06%. X-ray emission, presumably due to bombarding activity of electrons in current sheath at the anode tip was dominant, which is confirmed by the pinhole images. The feasibility of the device as an intense X-ray source for radiography is demonstrated.

  5. UGCT: New X-ray radiography and tomography facility

    Energy Technology Data Exchange (ETDEWEB)

    Masschaele, B.C. [Department of Subatomic and Radiation Physics, Ghent University, Proeftuinstraat 86, B-9000 Gent (Belgium)], E-mail: bert.masschaele@ugent.be; Cnudde, V. [Department of Geology and Soil Science, Ghent University, Krijgslaan 281, B-9000 Gent (Belgium); Dierick, M. [Department of Subatomic and Radiation Physics, Ghent University, Proeftuinstraat 86, B-9000 Gent (Belgium); Jacobs, P. [Department of Geology and Soil Science, Ghent University, Krijgslaan 281, B-9000 Gent (Belgium); Hoorebeke, L. van; Vlassenbroeck, J. [Department of Subatomic and Radiation Physics, Ghent University, Proeftuinstraat 86, B-9000 Gent (Belgium)

    2007-09-21

    The UGCT (University Gent Computer Tomography) facility, a cooperation between the Radiation Physics research group and the Sedimentary Geology and Engineering Geology research group is a new CT facility providing a large range of scanning possibilities. Formerly a Skyscan 1072 was used to perform X-ray micro-CT scans at the UGCT facility and although this is a very powerful instrument, there were needs for a higher resolution and more flexibility. Therefore, the UCGT facility started the construction of a multidisciplinary micro-CT scanner inside a shielded room with a maximum flexibility of the set-up. The X-ray tube of this high-resolution CT scanner is a state-of-the-art open-type device with dual head: one head for high power micro-CT and one for sub-micro- or also called nano-CT. An important advantage of this scanner is that different detectors can be used to optimize the scanning conditions of the objects under investigation. The entire set-up is built on a large optical table to obtain the highest possible stability. Due to the flexible set-up and the powerful CT reconstruction software 'Octopus', it is possible to obtain the highest quality and the best signal-to-noise of the reconstructed images for each type of sample.

  6. Prompt and afterglow X-ray emission from the X-Ray Flash of 2002 April 27

    CERN Document Server

    Amati, L; in 't Zand, J J M; Capalbi, M; Landi, R; Soffitta, P; Vetere, L; Antonelli, L A; Costa, E; Del Sordo, S; Feroci, M; Guidorzi, C; Heise, J; Masetti, N; Montanari, E; Nicastro, L; Palazzi, E; Piro, L

    2004-01-01

    We report on the X-ray observations of the X-ray flash (XRF) which occurred on 2002 April 27, three days before BeppoSAX was switched off. The event was detected with the BeppoSAX Wide Field Cameras but not with the Gamma ray Burst Monitor. A follow-up observation with the BeppoSAX Narrow Field Instruments was soon performed and a candidate afterglow source was discovered. We present the results obtained. We also include the results obtained from the observations of the XRF field with the Chandra X-ray satellite. The spectral analysis of the prompt emission shows that the peak energy of the EF(E) spectrum is lower than 5.5 keV, with negligible spectral evolution. The X-ray afterglow spectrum is consistent with a power law model with photon index of about 2, while the 2-10 keV flux fades as a power law with a decay index -1.33. Both these indices are typical of GRBs. A very marginal excess around 4.5-5 keV is found in the afterglow spectrum measured by BeppoSAX . As for many GRBs, the extrapolation of the 2-10...

  7. AIRIX: a new tool for flash radiography in detonics

    Science.gov (United States)

    Cavailler, Claude

    2001-04-01

    AIRIX is an induction linear accelerator which will be used for flash radiography in Commissariat A L'Energie Atomique In France. Designed to produce an X-ray dose of some hundreds Rads at 1 meter with an X-ray focal spot size diameter of less than 2 mm (LANL-CEA DAM definition), this facility consists in a 3,8 MeV/2 kA pulsed electron injector and 15,4 MeV induction accelerator powered by 32 high voltage generators. A prototype of this accelerator, called PIVAIR, has been studied and realized in CEA CESTA near Bordeaux. PIVAIR is a validation step for AIRIX at 8 MeV. It includes an injector (3,6 MeV, 3,2 kA, 60 ns) and 16 induction cells supplied by 8 high voltage generators (250 kV, 70 ns). Two different technologies of induction cells have been tested (Rexolite insulator or ferrite Under Vacuum). We have chosen ferrite under vacuum cells technology after comparison of results on beam transport and reliability tests. A focusing experiment at 7.2 MeV of the electron beam has been achieved during summer 1997. We have begun to produce X-rays in October 1997. A dose level of 50 Rad at 1 meter has been achieved with an X-ray spot size diameter of 3.5 to 4 mm (LANL-CEA DAM definition). Static flash radiography of very dense object have been achieved from November 1997 until February 1998. We have been able to test in situ new kinds of very high sensitive X-ray detectors and to check they had reached our very ambitious goals: quantum efficiency at 5 MeV > 50% instead of 1% for luminous screens and film, sensitivity radiographic luminous screens and films), dynamic range > 100, resolution radiograph of the device explosion under test with the high stopping power detector located in a blast protection set behind the device. In this communication we will present all these techniques which correspond to a significant effort of CEA begun in 1992. AIRIX facility will be available to run detonics experiments before end of 2000.

  8. Development and evaluation of a four-channel digital flash X-ray imaging system

    CERN Document Server

    Wang Yi; Du Hong Lian; Li Yuan Jing; Tian Hui

    2003-01-01

    A four-channel digital flash X-ray imaging system has been developed in our lab. The four flash X-ray heads and four detectors can be used to obtain four radiographic images at four time intervals of an explosion and ballistic trajectory. The cascaded imaging system mainly consists of three parts: (1) a phosphor screen to convert incident X-rays into visible photons; (2) a lens to efficiently collect visible photons emitted by the phosphor screen; and (3) a charge coupled device image sensor to obtain the visible light image. From the analysis of signal and noise propagation, the system is not X-ray quantum-limited, rather the system has secondary quantum sink at the light collecting stage. The construction of the system, theoretical and experimental analysis of performance are presented.

  9. The upper limits of the SNR in radiography and CT with polyenergetic x-rays.

    Science.gov (United States)

    Shikhaliev, Polad M

    2010-09-21

    The aim of the study is to determine the upper limits of the signal-to-noise ratio (SNR) in radiography and computed tomography (CT) with polyenergetic x-ray sources. In x-ray imaging, monoenergetic x-rays provide a higher SNR compared to polyenergetic x-rays. However, the SNR in polyenergetic x-ray imaging can be increased when a photon-counting detector is used and x-rays are optimally weighted according to their energies. For a particular contrast/background combination and at a fixed x-ray entrance skin exposure, the SNR in energy-weighting x-ray imaging depends on tube voltage and can be maximized by selecting the optimal tube voltage. The SNR in energy-weighted x-ray images acquired at this optimal tube voltage is the highest SNR that can be achieved with polyenergetic x-ray sources. The optimal tube voltages and the highest SNR were calculated and compared to the SNR of monoenergetic x-ray imaging. Monoenergetic, energy-weighting polyenergetic and energy-integrating polyenergetic x-ray imagings were simulated at a fixed entrance skin exposure of 20 mR. The tube voltages varied in the range of 30-140 kVp with 10 kV steps. Contrast elements of CaCO(3), iodine, adipose and tumor with thicknesses of 280 mg cm(-2), 15 mg cm(-2), 1 g cm(-2) and 1 g cm(-2), respectively, inserted in a soft tissue background with 10 cm and 20 cm thicknesses, were used. The energy weighting also improves the contrast-to-noise ratio (CNR) in CT when monoenergetic CT projections are optimally weighted prior to CT reconstruction (projection-based weighting). Alternatively, monoenergetic CT images are reconstructed, optimally weighted and composed to yield a final CT image (image-based weighting). Both projection-based and image-based weighting methods improve the CNR in CT. An analytical approach was used to determine which of these two weighting methods provides the upper limit of the CNR in CT. The energy-weighting method was generalized and expanded as a weighting method applicable

  10. Spot size diagnostics for flash radiographic X-ray sources at LAPA

    Institute of Scientific and Technical Information of China (English)

    LI Cheng-Gang; LI Qin; SHI Jin-Shui; DENG Jian-Jun

    2009-01-01

    Spot size is one of the parameters to characterize the performance of a radiographic X-ray source.It determines the degree of blurring due to magnification directly.In recent years,a variety of measurement methods have been used to diagnose X-ray spot size at Laboratory of Accelerator Physics and Application (LAPA).Computer simulations and experiments showed that using a rolled-edge to measure the spot size are more accurate,and the intensity distribution of X-ray source was obtained by a device with a square aperture.Experimental and simulation results on a flash X-ray source at our laboratory are presented and discussed in this paper.In addition,a new method for time resolved diagnostics of X-ray spot size is introduced too.

  11. LIGHT SOURCE: Spot size diagnostics for flash radiographic X-ray sources at LAPA

    Science.gov (United States)

    Li, Cheng-Gang; Li, Qin; Shi, Jin-Shui; Deng, Jian-Jun

    2009-06-01

    Spot size is one of the parameters to characterize the performance of a radiographic X-ray source. It determines the degree of blurring due to magnification directly. In recent years, a variety of measurement methods have been used to diagnose X-ray spot size at Laboratory of Accelerator Physics and Application (LAPA). Computer simulations and experiments showed that using a rolled-edge to measure the spot size are more accurate, and the intensity distribution of X-ray source was obtained by a device with a square aperture. Experimental and simulation results on a flash X-ray source at our laboratory are presented and discussed in this paper. In addition, a new method for time resolved diagnostics of X-ray spot size is introduced too.

  12. Predicted flash x-ray environments using standard converter configurations

    Energy Technology Data Exchange (ETDEWEB)

    Halbleib, J.A.; Sanford, T.W.L.

    1985-09-01

    Using a sophisticated Monte Carlo model, we have obtained predictions of the forward radiation fields generated by a series of monoenergetic electron sources, with kinetic energies ranging from 0.5 to 15.0 MeV, normally incident on standard converter configurations. The tantalum converter foil thickness that maximizes the total forward-going x-ray energy ranges from 0.3 times the continuous-slowing-down-approximation electron range at 0.5 MeV to 0.6 times that range at 15.0 MeV. This result is not very sensitive to the presence or absence of typical electron absorbers or debris shields. The forward extraction efficiency exhibits a slightly superlinear dependence on source electron kinetic energy. Electron backscatter and photon absorption are shown to be the chief transport phenomena that limit x-ray extraction. Dependence of x-ray spectra on emission angle results from the complicated interplay of cross-section kinematics, slant-thickness absorption, and slant-thickness buildup. The response of common dosimetry materials to the radiation fields was also studied. The systematics of energy deposition in high-Z and low-Z dosimetry materials as a function of source energy, converter geometry, and emission angle are presented in terms of an effective absorption coefficient. The utility of this coefficient for predicting the energy deposition in one material from the measured dose in another material is demonstrated. It is shown that the converter thickness that optimizes dose is less than the thickness that optimizes the forward extraction efficiency. 11 refs., 32 figs.

  13. The first years with the AIRIX flash x-ray radiographic facility

    Science.gov (United States)

    Merle, Eric; Delvaux, Jacques; Mouillet, Marc; Pierret, Olivier; Nore, Didier; Vermare, Christophe

    2003-07-01

    The AIRIX induction accelerator used for flash X-ray radiography is operational for two years, at CEA-Moronvilliers near REIMS, France). This single shot machine is composed by: (1) an injector that delivers a 3.6 - 4 MeV/2-3 kA/60 ns electron beam. (2) an accelerator composed by 16 blocks of 4 induction cells, that accelerate and transport the electron beam until 20 MeV. (3) 32 High Voltage generators that powered the induction cells: 250 kV per cell. (4) a drift and focalizing section, that transport the beam from the accelerator to the final Tantalum target. The acceptance test of this installation has been made in 2000. For that step we have choosen to work with a 2 kA electron beam. All the criteria for AIRIX qualification for hydrotest experiment have been reached with this current. We present in this paper the different measurements we made to characterize the electron beam from the injector until the end of the accelerator and the adequation with the results and the beam transport calculation. The beam image is realized with a fast gated camera that observes the Optical Transition Radiation(OTR) (produced when a charged particle passes from the vacuum to the material of a metallic foil) or Cerenkov Radiation (CR). To insure the AIRIX peformances in the time and to improve them, we have begun some specific studies. In parallel to simulation codes for beam transport, we develop optical diagnostics. The idea is to explore the intrinsic characteristics of OTR to measure the electron beam profile and electron beam divergence in a single and same shot. That will also permit the measurement of the emittance of the beam. Those measurement will able to be time resolved if we associate a streak camera. For specific hydrotest experiment we will need to have more useful X-ray dose. To increase this parameter, we have begun some studies with a 3 kA electron beam. We show in this paper the electron beam characterization made at this current and the comparison with

  14. Compact source of narrowband and tunable X-rays for radiography

    Energy Technology Data Exchange (ETDEWEB)

    Banerjee, Sudeep, E-mail: sbanejee2@unl.edu [Department of Physics and Astronomy, University of Nebraska, Lincoln, NE 68516 (United States); Chen, Shouyuan; Powers, Nathan; Haden, Daniel; Liu, Cheng; Golovin, G.; Zhang, Jun; Zhao, Baozhen [Department of Physics and Astronomy, University of Nebraska, Lincoln, NE 68516 (United States); Clarke, S.; Pozzi, S. [Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI 48109 (United States); Silano, J.; Karwowski, H. [Department of Physics and Astronomy, University of North Carolina, Chapel Hill, NC 27599 (United States); Umstadter, Donald [Department of Physics and Astronomy, University of Nebraska, Lincoln, NE 68516 (United States)

    2015-05-01

    We discuss the development of a compact X-ray source based on inverse-Compton scattering with a laser-driven electron beam. This source produces a beam of high-energy X-rays in a narrow cone angle (5–10 mrad), at a rate of 10{sup 8} photons-s{sup −1}. Tunable operation of the source over a large energy range, with energy spread of ∼50%, has also been demonstrated. Photon energies >10 MeV have been obtained. The narrowband nature of the source is advantageous for radiography with low dose, low noise, and minimal shielding.

  15. The application and development of radiography technology based on x-ray

    Science.gov (United States)

    Chen, Hao; Xu, Zhou; Li, Ming

    2009-07-01

    Modern Radiography technology was combined with radiation physics and modern imaging processing, which was an important branch of information obtainment and processing. We can get the inside information of the object, by the X ray's attenuation when the ray penetrated the object, and depending on the computer's fast processing, we can see the slice imaging of the object. Computerized Tomography, Computerized Laminography, and Digital Radiography were important parts in Radiography. The institute of applied electronics, CAEP in the research of intense radiation had developed several advanced radiation sources and some advanced radiography imaging systems, for example, S-band small spot linear accelerator, full solid state modulator, C-band linear accelerator, high energy Tera-hertz radiation source and CT technology based on cone beam, DR technology, CL Technology etc. Such imaging systems had been applied in industrial NDT/NDE, security check, medical diagnosis, petroleum and gas pipeline inspection system etc.

  16. Computer-aided diagnosis of pulmonary diseases using x-ray darkfield radiography

    DEFF Research Database (Denmark)

    Einarsdottir, Hildur; Yaroshenko, Andre; Velroyen, Astrid;

    2015-01-01

    In this work we develop a computer-aided diagnosis (CAD) scheme for classification of pulmonary disease for grating-based x-ray radiography. In addition to conventional transmission radiography, the grating-based technique provides a dark-field imaging modality, which utilizes the scattering...... of three stages: (i) automatic lung segmentation; (ii) feature extraction from lung shape and dark-field image intensities; (iii) classification between healthy, emphysema and fibrosis lungs. A study of 102 mice was conducted with 34 healthy, 52 emphysema and 16 fibrosis subjects. Each image was manually...

  17. Extension of dynamic range in X-ray radiography using multi-color scintillation detector

    CERN Document Server

    Nittoh, K; Sakurai, T; Yoshida, T; Mochiki, K I

    2003-01-01

    A new imaging system using the multi-color scintillator Gd sub 2 O sub 2 S:Eu has been developed for the X-ray radiography. In this method a color Charge Coupled Device detects the weak blue and green photons associated with the transitions from the terms like sup 5 D sub 1 and sup 5 D sub 2 in the Eu-ions as well as the dominant red photons. As these transitions become appreciable and saturate at quite different intensity levels of the X-ray, we can realize a big extension of the dynamic range of the imaging almost by hundred times in comparison with the conventional monochromatic method. As a result, the new system makes it possible to take a clear image of any complex object, which consists of various parts of the different X-ray penetrability, from plastic to heavy metal, at a single shot.

  18. High-energy synchrotron X-ray radiography of shock-compressed materials

    Science.gov (United States)

    Rutherford, Michael E.; Chapman, David J.; Collinson, Mark A.; Jones, David R.; Music, Jasmina; Stafford, Samuel J. P.; Tear, Gareth R.; White, Thomas G.; Winters, John B. R.; Drakopoulos, Michael; Eakins, Daniel E.

    2015-06-01

    This presentation will discuss the development and application of a high-energy (50 to 250 keV) synchrotron X-ray imaging method to study shock-compressed, high-Z samples at Beamline I12 at the Diamond Light Source synchrotron (Rutherford-Appleton Laboratory, UK). Shock waves are driven into materials using a portable, single-stage gas gun designed by the Institute of Shock Physics. Following plate impact, material deformation is probed in-situ by white-beam X-ray radiography and complimentary velocimetry diagnostics. The high energies, large beam size (13 x 13 mm), and appreciable sample volumes (~ 1 cm3) viable for study at Beamline I12 compliment existing in-house pulsed X-ray capabilities and studies at the Dynamic Compression Sector. The authors gratefully acknowledge the ongoing support of Imperial College London, EPSRC, STFC and the Diamond Light Source, and AWE Plc.

  19. Compensational scintillation detector with a flat energy response for flash X-ray measurements

    Science.gov (United States)

    Chen, Liang; Ouyang, Xiaoping; Liu, Bin; Liu, Jinliang; Quan, Lin; Zhang, Zhongbing

    2013-01-01

    To measure the intensity of flash X-ray sources directly, a novel scintillation detector with a fast time response and flat energy response is developed by combining film scintillators of doped ZnO crystal and fast organic scintillator together. Through compensation design, the dual-scintillator detector (DSD) achieved a flat energy response to X-rays from tens of keV to several MeV, and sub-nanosecond time response by coupling to ultrafast photo-electronic devices. A prototype detector was fabricated according to the theoretical design; it employed ZnO:In and EJ228 with thicknesses of 0.3 mm and 0.1 mm, respectively. The energy response of this detector was tested on monoenergetic X-ray and γ-ray sources. The detector performs very well with a sensitivity fluctuation below 5% for 8 discrete energy points within the 40-250 keV energy region and for other energies of 662 keV and 1.25 MeV as well, showing good accordance with the theoretical design. Additionally, the detector works properly for the application to the flash X-ray radiation field absolute intensity measurement. This DSD may be very useful for the diagnosis of time-resolved dynamic physical processes of flash X-ray sources without knowing the exact energy spectrum.

  20. Recent developments in a CdTe-based x-ray detector for digital radiography

    Science.gov (United States)

    Glasser, Francis; Martin, Jean-Luc; Thevenin, Bernard; Schermesser, Patrick; Pantigny, Philippe; Laurent, Jean Yves; Rambaud, Philippe; Pitault, Bernard; Paltrier, Sylvain

    1997-05-01

    The performance of a new CdTe based x-ray detector devoted to digital radiography are presented. The detectors consist of a 6 cm2 CdTe 2D-array connected to CMOS readout circuit by indium bumps. The final image has 400 X 600 pixels with a 50 micron pitch. This solid-state detector presents the advantages of direct conversion, i.e. high stopping power with high spatial resolution and a significantly higher signal than commercially available scintillator/photodetector systems. The experimental results show excellent linearity, spatial resolution and detective quantum efficiency. The MTF was measured by the angled-slit method: 20 to 30 percent at 10 1p/mm depending on the incident x-ray energy. The measured DQE is about 0.8 at 40 KeV and 100 (mu) Gray dose. Our simulation shows that these experimental results do not reach the theoretical limit. Further improvements are in progress. The first industrial application will be dental radiography due to the small size and the excellent performances. We also tested the detector with x-rays form 20 KeV to 1.25 MeV. Of course the CdTe thickness should then be adapted to the incident x-ray energy.

  1. A dynamic material discrimination algorithm for dual MV energy X-ray digital radiography.

    Science.gov (United States)

    Li, Liang; Li, Ruizhe; Zhang, Siyuan; Zhao, Tiao; Chen, Zhiqiang

    2016-08-01

    Dual-energy X-ray radiography has become a well-established technique in medical, industrial, and security applications, because of its material or tissue discrimination capability. The main difficulty of this technique is dealing with the materials overlapping problem. When there are two or more materials along the X-ray beam path, its material discrimination performance will be affected. In order to solve this problem, a new dynamic material discrimination algorithm is proposed for dual-energy X-ray digital radiography, which can also be extended to multi-energy X-ray situations. The algorithm has three steps: α-curve-based pre-classification, decomposition of overlapped materials, and the final material recognition. The key of the algorithm is to establish a dual-energy radiograph database of both pure basis materials and pair combinations of them. After the pre-classification results, original dual-energy projections of overlapped materials can be dynamically decomposed into two sets of dual-energy radiographs of each pure material by the algorithm. Thus, more accurate discrimination results can be provided even with the existence of the overlapping problem. Both numerical and experimental results that prove the validity and effectiveness of the algorithm are presented.

  2. Measuring x-ray spectra of flash radiographic sources [PowerPoint

    Energy Technology Data Exchange (ETDEWEB)

    Gehring, Amanda Elizabeth [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Espy, Michelle A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Haines, Todd Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Mendez, Jacob [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Moir, David C. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Sedillo, Robert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Shurter, Roger P. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Volegov, Petr Lvovich [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Webb, Timothy J [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-11-02

    The x-ray spectra of flash radiographic sources are difficult to measure. The sources measured were Radiographic Integrated Test Stand-6 (370 rad at 1 m; 50 ns pulse) and Dual Axis Radiographic Hydrodynamic Test Facility (DARHT) (550 rad at 1 m; 50 ns pulse). Features of the Compton spectrometer are described, and spectra are shown. Additional slides present data on instrumental calibration.

  3. Very Early Optical Afterglows for Geometric Models of X-ray Flashes and X-ray Rich GRBs

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    If X-ray flashes (XRFs) and X-ray rich Gamma-ray Bursts (XRRGs) have the same origin as the Gamma-ray bursts (GRBs) but are viewed off-center from structured jets, their early afterglows may differ from those of GRBs, and when the ultra-relativistic outflow interacts with the surrounding medium, there are two shocks formed, a forward shock (FS), and a reverse shock (RS). We calculate numerically the early afterglow powered by uniform jets, Gaussian jets and power-law jets in the forward-reverse shock scenario. A set of differential equations govern the dynamical evolution. The synchrotron self-Compton effect has been taken into account in the calculation. In the uniform jets, the very early afterglows of XRRGs and XRFs are significantly lower than the GRBs and the observed peak times of RS emission are later in the interstellar medium environment. The RS components in XRRGs and XRFs are difficult to detect, but in the stellar wind environment, the reduction of the very early flux and the delay of the RS peak time are not so remarkable. In nonuniform jets (Gaussian and power-law jets), where there are emission materials on the line of sight, the very early light curve resembles equivalent isotropic ejecta in general although the RS flux decay index shows notable deviations if the RS is relativistic (in stellar wind).

  4. A Search for X-Ray Flashes with XMM-Newton

    CERN Document Server

    Law, N M; Kulkarni, S R

    2003-01-01

    We searched for X-ray flashes (XRFs) -- which we defined as ~10s duration transient X-ray events observable in the 0.4-15 keV passband -- in fields observed using XMM-Newton with the EPIC/pn detector. While we find two non-Poissonian events, the astrophysical nature of the events is not confirmed in fully simultaneous observations with the EPIC/MOS detectors, and we conclude that the events are anomalous to the EPIC/pn detector. We find a 90% upper limit on the number of flashes per sky per year at two different incoming flash fluxes. These limits are consistent with an extrapolation from the BeppoSAX/WFC XRF rate at much higher fluxes (about a factor of 10^5), assuming an homogenous population, and with a previous, more stringent limit derived from ROSAT pointed observations.

  5. Generation and dose distribution measurement of flash x-ray in KALI-5000 system

    Science.gov (United States)

    Menon, Rakhee; Roy, Amitava; Mitra, S.; Sharma, A.; Mondal, J.; Mittal, K. C.; Nagesh, K. V.; Chakravarthy, D. P.

    2008-10-01

    Flash x-ray generation studies have been carried out in KALI-5000 Pulse power system. The intense relativistic electron beam has been bombarded on a tantalum target at anode to produce flash x-ray via bremsstrahlung conversion. The typical electron beam parameter was 360 kV, 18 kA, and 100 ns, with a few hundreds of A/cm2 current density. The x-ray dose has been measured with calcium sulfate:dysposium (CaSO4:Dy) thermoluminescent dosimeter and the axial dose distribution has been characterized. It has been observed that the on axis dose falls of with distance ˜1/xn, where n varies from 1.8 to 1.85. A maximum on axis dose of 46 mrad has been measured at 1 m distance from the source. A plastic scintillator with optical fiber coupled to a photomultiplier tube has been developed to measure the x-ray pulse width. The typical x-ray pulse width varied from 50 to 80 ns.

  6. The use of x-ray micro-digital radiography for clay material inspection

    Science.gov (United States)

    Suparta, Gede B.; Louk, Andreas C.; Kurniasari, Herlina; Wiguna, Gede A.

    2014-06-01

    An x-ray micro-digital radiography (μ-DR) system has been developed at the Gadjah Mada University Indonesia. The μ- DR system was developed as an add-on unit on an x-ray Diffraction (XRD) system using one extra beam-port as its radiation source. A fluorescence screen encapsulated in a dark tube then coupled by a CCD camera was used as an imaging plate. The radiography objects were some sample clays for earthen or ceramic material of handicraft. The clays differ by particle size, namely: 40 mesh, 60 mesh, 80 mesh, and 100 mesh. The objects were put in front of the imaging plate and then they were exposed by x-ray beam. The image formed on the screen was captured by the CCD camera and then it was converted into digital microradiograph of a size of 720x576. Then, after noise suppression process and normalization procedure, the microradiograph were compared each other by considering particle size. This facility can be used as a non-destructive and testing material studies for examining the quality of earthen or ceramic handicraft.

  7. Archaeometric studies by neutron, x-ray radiography and microCT

    Science.gov (United States)

    Latini, R. M.; Bellido, A. V. B.; Vinagre Filho, U. M.; Souza, M. I. S.; Lima, I.; Oliveira, D. F.; Lopes, R. T.

    2013-05-01

    The aim of this study is to investigate manufacturing techniques used in prehistoric Brazilian pottery from Acre state and Araruama, Rio de Janeiro state, Brazil, using Neutron and X-Ray Radiography. For the neutrongraphy different fragments of pottery were submitted to a neutron flux of the order of 105n.cm-2.s-1 for 3 minutes at the Argonauta research reactor of the Instituto de Engenharia Nuclear (IEN)/CNEN. Digital processing techniques using imaging plate were applied to process the image of the selected sample. For the radiography the sample were exposed to an X-Rays in the Feinfocus Model FX100 and the image was obtained by Flat Panel GE IT Model DXR 250V at the Laboratório de Instrumentação Nuclear (LIN) - COPPE/UFRJ. The Neutrongraphy and radiography shows two different manufacturing details: palette and rollers and the microtomography shows cavities in the clay body and different temper applied in the pottery production. The preliminary results shows promising techniques applied for the pottery manufacturing information and as complement for better understanding the ceramics classification and precedence.

  8. Demonstration of combined radiography and x-ray scattering measurements of shocked foam

    Science.gov (United States)

    Belancourt, Patrick; Theobald, Wolfgang; Keiter, Paul; Collins, Timothy; Bonino, Mark; Regan, Sean; Kozlowski, Pawel; Drake, Paul

    2016-10-01

    High-energy-density physics experiments often use foams due to their low, tunable densities and being machinable. Simulating these experiments can be difficult due to the equation of state being largely unknown for shocked foams. This talk will focus on an experiments dedicated to measuring the temperature, ionization and density of shocked foams from simultaneous x-ray Thomson scattering and radiography measurements. The foam used in this experiment is carbonized resorcinol formaldehyde foam with an initial density of 0.1 g/cc. One OMEGA EP beam drives a shock into the foam, while the remaining three beams irradiate a nickel foil coated with titanium to create the x-ray backlighter.. The primary diagnostic for this platform, the imaging x-ray Thomson spectrometer (IXTS), spectrally resolves the scattered x-ray beam while imaging in one spatial dimension. The IXTS is ideally suited to measure plasma conditions upstream, downstream and at the shock front in the foam. Preliminary results from this experiment will be shown. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number DE-NA0001944, the University of Rochester, and the New York State Energy Research and Development Authority.

  9. Correlation of X-Ray Vector Radiography to Bone Micro-Architecture

    Science.gov (United States)

    Schaff, Florian; Malecki, Andreas; Potdevin, Guillaume; Eggl, Elena; Noël, Peter B.; Baum, Thomas; Garcia, Eduardo Grande; Bauer, Jan S.; Pfeiffer, Franz

    2014-01-01

    Besides the overall mass density, strength of trabecular bone depends significantly on its microstructure. However, due to dose constraints in medical CT imaging, it is impossible to gain sufficient information about very fine bone structures in vivo on the micrometer scale. Here we show that a recently developed method of X-ray vector radiography (XVR), an imaging method which uses X-ray scattering information to form an image, allows predictions on the bone microstructure without the explicit need to spatially resolve even individual trabeculae in the bone. We investigated thick human femoral bone samples and compared state-of-the-art μCT data with XVR imaging. A model is presented which proves that XVR imaging yields information directly correlated with the trabecular microstructure. This opens up possibilities of using XVR as a tool to help early diagnosis of bone diseases, such as osteoporosis.

  10. Skull x-ray

    Science.gov (United States)

    X-ray - head; X-ray - skull; Skull radiography; Head x-ray ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  11. Interior Temperature Measurement Using Curved Mercury Capillary Sensor Based on X-ray Radiography

    Science.gov (United States)

    Chen, Shuyue; Jiang, Xing; Lu, Guirong

    2017-07-01

    A method was presented for measuring the interior temperature of objects using a curved mercury capillary sensor based on X-ray radiography. The sensor is composed of a mercury bubble, a capillary and a fixed support. X-ray digital radiography was employed to capture image of the mercury column in the capillary, and a temperature control system was designed for the sensor calibration. We adopted livewire algorithms and mathematical morphology to calculate the mercury length. A measurement model relating mercury length to temperature was established, and the measurement uncertainty associated with the mercury column length and the linear model fitted by least-square method were analyzed. To verify the system, the interior temperature measurement of an autoclave, which is totally closed, was taken from 29.53°C to 67.34°C. The experiment results show that the response of the system is approximately linear with an uncertainty of maximum 0.79°C. This technique provides a new approach to measure interior temperature of objects.

  12. New X-ray testing methods of aerosol products for industrial radiography

    Science.gov (United States)

    Bozydar Knyziak, Adrian; Rzodkiewicz, Witold; Kaczorowska, Ewa; Derlacinski, Michal

    2017-02-01

    An amount of product in e.g. an aerosol canister is not difficult to estimate by weighing a filled can and subtracting the tare of packaging. In this way, we can obtain the net weight of the ingredients present in the can. Although, this does not indicate the volumetric content. Therefore, in the paper, the fundamental (the weight method and given by FEICA) and new methods (given by authors) related to the determination of the volumetric content of canister filled with aeorosol products are presented. The new methods are based on direct digital radiography (DR) using X-ray radiation. For the needs of new methods, the X-ray CCD-DR imaging system was built and developed in our Laboratory in Department of Radiation and Vibration at the Central Office of Measures. For comparison purposes, with regard to the volumetric content, a lot of metal cans of capacities 140, 185, 450, 700 ml were inspected. In future, computed tomography (CT) for industrial radiography in our laboratory will be used. Currently, an algorithm for CT is being tested. It will give us possibility for very precise measurements to determine volumetric content of examined canisters.

  13. Assessment of image quality in x-ray radiography imaging using a small plasma focus device

    Science.gov (United States)

    Kanani, A.; Shirani, B.; Jabbari, I.; Mokhtari, J.

    2014-08-01

    This paper offers a comprehensive investigation of image quality parameters for a small plasma focus as a pulsed hard x-ray source for radiography applications. A set of images were captured from some metal objects and electronic circuits using a low energy plasma focus at different voltages of capacitor bank and different pressures of argon gas. The x-ray source focal spot of this device was obtained to be about 0.6 mm using the penumbra imaging method. The image quality was studied by several parameters such as image contrast, line spread function (LSF) and modulation transfer function (MTF). Results showed that the contrast changes by variations in gas pressure. The best contrast was obtained at a pressure of 0.5 mbar and 3.75 kJ stored energy. The results of x-ray dose from the device showed that about 0.6 mGy is sufficient to obtain acceptable images on the film. The measurements of LSF and MTF parameters were carried out by means of a thin stainless steel wire 0.8 mm in diameter and the cut-off frequency was obtained to be about 1.5 cycles/mm.

  14. High-energy x-ray grating-based phase-contrast radiography of human anatomy

    Science.gov (United States)

    Horn, Florian; Hauke, Christian; Lachner, Sebastian; Ludwig, Veronika; Pelzer, Georg; Rieger, Jens; Schuster, Max; Seifert, Maria; Wandner, Johannes; Wolf, Andreas; Michel, Thilo; Anton, Gisela

    2016-03-01

    X-ray grating-based phase-contrast Talbot-Lau interferometry is a promising imaging technology that has the potential to raise soft tissue contrast in comparison to conventional attenuation-based imaging. Additionally, it is sensitive to attenuation, refraction and scattering of the radiation and thus provides complementary and otherwise inaccessible information due to the dark-field image, which shows the sub-pixel size granularity of the measured object. Until recent progress the method has been mainly limited to photon energies below 40 keV. Scaling the method to photon energies that are sufficient to pass large and spacious objects represents a challenging task. This is caused by increasing demands regarding the fabrication process of the gratings and the broad spectra that come along with the use of polychromatic X-ray sources operated at high acceleration voltages. We designed a setup that is capable to reach high visibilities in the range from 50 to 120 kV. Therefore, spacious and dense parts of the human body with high attenuation can be measured, such as a human knee. The authors will show investigations on the resulting attenuation, differential phase-contrast and dark-field images. The images experimentally show that X-ray grating-based phase-contrast radiography is feasible with highly absorbing parts of the human body containing massive bones.

  15. Spatial resolution measurements of the advanced radiographic capability x-ray imaging system at energies relevant to Compton radiography

    Science.gov (United States)

    Hall, G. N.; Izumi, N.; Landen, O. L.; Tommasini, R.; Holder, J. P.; Hargrove, D.; Bradley, D. K.; Lumbard, A.; Cruz, J. G.; Piston, K.; Lee, J. J.; Romano, E.; Bell, P. M.; Carpenter, A. C.; Palmer, N. E.; Felker, B.; Rekow, V.; Allen, F. V.

    2016-11-01

    Compton radiography provides a means to measure the integrity, ρR and symmetry of the DT fuel in an inertial confinement fusion implosion near peak compression. Upcoming experiments at the National Ignition Facility will use the ARC (Advanced Radiography Capability) laser to drive backlighter sources for Compton radiography experiments and will use the newly commissioned AXIS (ARC X-ray Imaging System) instrument as the detector. AXIS uses a dual-MCP (micro-channel plate) to provide gating and high DQE at the 40-200 keV x-ray range required for Compton radiography, but introduces many effects that contribute to the spatial resolution. Experiments were performed at energies relevant to Compton radiography to begin characterization of the spatial resolution of the AXIS diagnostic.

  16. Soft x-ray laser spectroscopy on trapped highly charged ions at FLASH.

    Science.gov (United States)

    Epp, S W; López-Urrutia, J R Crespo; Brenner, G; Mäckel, V; Mokler, P H; Treusch, R; Kuhlmann, M; Yurkov, M V; Feldhaus, J; Schneider, J R; Wellhöfer, M; Martins, M; Wurth, W; Ullrich, J

    2007-05-04

    In a proof-of-principle experiment, we demonstrate high-resolution resonant laser excitation in the soft x-ray region at 48.6 eV of the 2 (2)S(1/2) to 2 (2)P(1/2) transition of Li-like Fe23+ ions trapped in an electron beam ion trap by using ultrabrilliant light from Free Electron Laser in Hamburg (FLASH). High precision spectroscopic studies of highly charged ions at this and upcoming x-ray lasers with an expected accuracy gain up to a factor of a thousand, become possible with our technique, thus potentially yielding fundamental insights, e.g., into basic aspects of QED.

  17. Inspection of the metal composite materials using a combination of X-ray radiography and Neutron Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Vavrik, D [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, CZ 12800 Prague 2 (Czech Republic); Jeon, I [School of Mechanical Systems Engineering, Chonnam National University, Gwangju (Korea, Republic of); Lehmann, E; Kaestner, A [Paul Scherrer Institut, Neutron Imaging and Activation Group, WBBA/110 , CH-5232 Villigen PSI (Switzerland); Vacik, J, E-mail: vavrik@itam.cas.cz [Nuclear Physics Institute AS CR and Research Center Rez CZ-25068 (Czech Republic)

    2011-03-01

    Neutron Imaging and X-ray radiography are complementary methods from the point of view of the visibility and contrast of the material imaged. One potential application is the observation of the behavior of so-called 'metal composite materials', in which metallic and light material parts are combined. This material type is commonly used in the aerospace industry. Neutron Imaging is a suitable tool for the observation of the structure of light materials in an environment of heavier elements like metals. X-ray radiography on other hand is an appropriate tool for the observation of geometry of metal components inside an environment of lighter materials.

  18. Characterisation of flash X-ray source generated by Kali-1000 Pulse Power System

    Science.gov (United States)

    Satyanarayana, N.; Durga Prasada Rao, A.; Mittal, K. C.

    2016-02-01

    The electron beam-driven Rod Pinch Diode (RPD) is presently fielded on KALI-1000 Pulse Power System at Bhabha Atomic Research Centre, Visakhapatnam and is a leading candidate for future flash X-ray radiographic sources. The diode is capable of producing less than 2-mm radiation spot sizes and greater than 350 milli rads of dose measured at 1 m from the X-ray source. KALI-1000 Pulse Power Source is capable of delivering up to 600 kV using a Tesla Transformer with Demineralized Insulated Transmission Line (DITL), the diode typically operates between 250-330 kV . Since the radiation dose has a power-law dependence on diode voltage, this limits the dose production on KALI-1000 system. Radiation dose with angular variation is measured using thermoluminescent detectors (TLD's) and the X-ray spot size is measured using pin hole arrangement with image plate (IP) to obtain the time-integrated source profile as well as a time-resolved spot diagnostic. An X-ray pinhole camera was used to pick out where the energetic e-beam connects to the anode. Ideally the diode should function such that the radiation is emitted from the tip. The camera was mounted perpendicular to the machine's axis to view the radiation from the tip. Comparison of the spot sizes of the X-ray sources obtained by the pin hole and rolled edge arrangements was carried and results obtained by both the techniques are with in ± 10% of the average values.

  19. Progress on the Flash X-Ray Optical Transition Radiation Diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Tang, V; Houck, T; Brown, C

    2008-03-30

    This document summarizes the Flash X-Ray accelerator (FXR) optical transition radiation (OTR) spot-size diagnostics efforts in FY07. During this year, new analysis, simulation, and experimental approaches were utilized to interpret OTR spot data from both dielectric foils such as Kapton (VN type) and metal coated foils. Significant new findings of the intricacies involved in the diagnostic and of FXR operational issues were achieved. Geometry and temperature based effects were found to affect the beam image profiles from the OTR foils. These effects must be taken into account in order to deduce accurately the beam current density profile.

  20. Computer-aided diagnosis of pulmonary diseases using x-ray darkfield radiography

    Science.gov (United States)

    Einarsdóttir, Hildur; Yaroshenko, Andre; Velroyen, Astrid; Bech, Martin; Hellbach, Katharina; Auweter, Sigrid; Yildirim, Önder; Meinel, Felix G.; Eickelberg, Oliver; Reiser, Maximilian; Larsen, Rasmus; Kjær Ersbøll, Bjarne; Pfeiffer, Franz

    2015-12-01

    In this work we develop a computer-aided diagnosis (CAD) scheme for classification of pulmonary disease for grating-based x-ray radiography. In addition to conventional transmission radiography, the grating-based technique provides a dark-field imaging modality, which utilizes the scattering properties of the x-rays. This modality has shown great potential for diagnosing early stage emphysema and fibrosis in mouse lungs in vivo. The CAD scheme is developed to assist radiologists and other medical experts to develop new diagnostic methods when evaluating grating-based images. The scheme consists of three stages: (i) automatic lung segmentation; (ii) feature extraction from lung shape and dark-field image intensities; (iii) classification between healthy, emphysema and fibrosis lungs. A study of 102 mice was conducted with 34 healthy, 52 emphysema and 16 fibrosis subjects. Each image was manually annotated to build an experimental dataset. System performance was assessed by: (i) determining the quality of the segmentations; (ii) validating emphysema and fibrosis recognition by a linear support vector machine using leave-one-out cross-validation. In terms of segmentation quality, we obtained an overlap percentage (Ω) 92.63  ±  3.65%, Dice Similarity Coefficient (DSC) 89.74  ±  8.84% and Jaccard Similarity Coefficient 82.39  ±  12.62%. For classification, the accuracy, sensitivity and specificity of diseased lung recognition was 100%. Classification between emphysema and fibrosis resulted in an accuracy of 93%, whilst the sensitivity was 94% and specificity 88%. In addition to the automatic classification of lungs, deviation maps created by the CAD scheme provide a visual aid for medical experts to further assess the severity of pulmonary disease in the lung, and highlights regions affected.

  1. Spectral X-ray Radiography for Safeguards at Nuclear Fuel Fabrication Facilities: A Feasibility Study

    Energy Technology Data Exchange (ETDEWEB)

    Gilbert, Andrew J.; McDonald, Benjamin S.; Smith, Leon E.

    2017-04-20

    The methods currently used by the International Atomic Energy Agency to account for nuclear materials at fuel fabrication facilities are time consuming and require in-field chemistry and operation by experts. Spectral X-ray radiography, along with advanced inverse algorithms, is an alternative inspection that could be completed noninvasively, without any in-field chemistry, with inspections of tens of seconds. The proposed inspection system and algorithms are presented here. The inverse algorithm uses total variation regularization and adaptive regularization parameter selection with the unbiased predictive risk estimator. Performance of the system is quantified with simulated X-ray inspection data and sensitivity of the output is tested against various inspection system instabilities. Material quantification from a fully-characterized inspection system is shown to be very accurate, with biases on nuclear material estimations of < 0.02%. It is shown that the results are sensitive to variations in the fuel powder sample density and detector pixel gain, which increase biases to 1%. Options to mitigate these inaccuracies are discussed.

  2. Radiography and X-ray fluorescence used to analyze cultural and artistic artifacts

    Energy Technology Data Exchange (ETDEWEB)

    Rizzutto, Marcia A.; Kajiya, Elizabeth M.; Campos, Pedro H.O.V. de; Almeida, Paula A.D., E-mail: rizzutto@if.usp.br, E-mail: elizabethkajiya@gmail.com [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil)

    2013-07-01

    Since 2003 the analyses of artistic and cultural heritage objects at LAMFI-USP (Laboratorio de Analises de Materiais com Feixes Ionicos), initially restricted to ion beam methods, are growing steadily. Since then, alternative methodologies and procedures have been incorporated to better characterize these objects, which possess distinct physical characteristics and also high cultural and monetary value. The examinations in this kind of objects were expanded to other non-destructive analytical techniques like portable EDXRF (Energy Dispersive X-ray Fluorescence) analysis, X-ray radiography, visible photography, UV (ultraviolet) and IR (infrared) light imaging that are helping to better understand these art objects, particularly paintings. These techniques are helping the analyses of the conservation state of the objects and also revealing characteristics of the painter such as underlying drawings, which help understand the creative process of the artist. These new procedures of analysis are aimed to enable better analytic research in archaeology and artistic and cultural heritage objects and to provide results that subsidize authentic investigations of art objects as well as the origin of archaeological artifacts, while stimulating archeometry and 'arteometry' research in Brazilian Museums. (author)

  3. Non-destructive investigation of a time capsule using neutron radiography and X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    MacDonald, B.L., E-mail: macdonbl@mcmaster.ca [McMaster University, Department of Medical Physics and Applied Radiation Sciences, Hamilton (Canada); Vanderstelt, J., E-mail: joshv@nray.ca [Nray Services Inc., 56A Head Street, Dundas, ON (Canada); O’Meara, J. [University of Guelph, Department of Physics, Guelph (Canada); McNeill, F.E. [McMaster University, Department of Medical Physics and Applied Radiation Sciences, Hamilton (Canada)

    2016-01-15

    Non-destructive analytical techniques are becoming increasingly important for the study of objects of cultural heritage interest. This study applied two techniques: X-ray fluorescence and neutron radiography, for the investigation of a capped, tubular metal object recovered from an urban construction site in Gore Park, Hamilton, Canada. The site is an urban park containing a World War I commemorative monument that underwent renovation and relocation. Historical documentation suggested that the object buried underneath the monument was a time capsule containing a paper document listing the names of 1800 Canadians who died during WWI. The purpose of this study was to assess the condition of the object, and to verify if it was what the historical records purported. XRF analysis was used to characterize the elemental composition of the metal artifact, while neutron radiography revealed that its contents were congruent with historical records and remained intact after being interred for 91 years. Results of this study demonstrate the value of non-destructive techniques for the analysis and preservation of cultural heritage.

  4. Non-destructive investigation of a time capsule using neutron radiography and X-ray fluorescence

    Science.gov (United States)

    MacDonald, B. L.; Vanderstelt, J.; O'Meara, J.; McNeill, F. E.

    2016-01-01

    Non-destructive analytical techniques are becoming increasingly important for the study of objects of cultural heritage interest. This study applied two techniques: X-ray fluorescence and neutron radiography, for the investigation of a capped, tubular metal object recovered from an urban construction site in Gore Park, Hamilton, Canada. The site is an urban park containing a World War I commemorative monument that underwent renovation and relocation. Historical documentation suggested that the object buried underneath the monument was a time capsule containing a paper document listing the names of 1800 Canadians who died during WWI. The purpose of this study was to assess the condition of the object, and to verify if it was what the historical records purported. XRF analysis was used to characterize the elemental composition of the metal artifact, while neutron radiography revealed that its contents were congruent with historical records and remained intact after being interred for 91 years. Results of this study demonstrate the value of non-destructive techniques for the analysis and preservation of cultural heritage.

  5. Real-Time X-ray Radiography Diagnostics of Components in Solid Rocket Motors

    Science.gov (United States)

    Cortopassi, A. C.; Martin, H. T.; Boyer, E.; Kuo, K. K.

    2012-01-01

    the recession of the solid propellant grain can drastically alter the flow-field and effect the recession of internal insulation and nozzle materials. Simultaneous measurement of the overall erosion rate, the development of the char layer, and the recession of the char-virgin interface during the motor operation can be rather difficult. While invasive techniques have been used with limited success, they have serious drawbacks. Break wires or make wire sensors can be installed into a sufficient number of locations in the charring material from which a time history of the charring surface can be deduced. These sensors fundamentally alter the local structure of the material in which they are imbedded. Also, the location of these sensors within the material is not known precisely without the use of an X-ray. To determine instantaneous recession rates, real-time X-ray radiography (X-ray RTR) has been utilized in several SRM experiments at PSU. The X-ray RTR system discussed in this paper consists of an X-ray source, X-ray image intensifier, and CCD camera connected to a capture computer. The system has been used to examine the ablation process of internal insulation as well as nozzle material erosion in a subscale SRM. The X-ray source is rated to 320 kV at 10 mA and has both a large (5.5 mm) and small (3.0 mm) focal spot. The lead-lined cesium iodide X-ray image intensifier produces an image which is captured by a CCD camera with a 1,000 x 1,000 pixel resolution. To produce accurate imagery of the object of interest, the alignment of the X-ray source to the X-ray image intensifier is crucial. The image sequences captured during the operation of an SRM are then processed to enhance the quality of the images. This procedure allows for computer software to extract data on the total erosion rate and the char layer thickness. Figure 1 Error! Reference source not found.shows a sequence of images captured during the operation the subscale SRM with the X-ray RTR system. The X-ray

  6. Aerogel Cherenkov detector for characterizing the intense flash x-ray source, Cygnus, spectrum

    Science.gov (United States)

    Kim, Y.; Herrmann, H. W.; McEvoy, A. M.; Young, C. S.; Hamilton, C.; Schwellenbach, D. D.; Malone, R. M.; Kaufman, M. I.; Smith, A. S.

    2016-11-01

    An aerogel Cherenkov detector is proposed to measure the X-ray energy spectrum from the Cygnus—intense flash X-ray source operated at the Nevada National Security Site. An array of aerogels set at a variety of thresholds between 1 and 3 MeV will be adequate to map out the bremsstrahlung X-ray production of the Cygnus, where the maximum energy of the spectrum is normally around 2.5 MeV. In addition to the Cherenkov radiation from aerogels, one possible competing light-production mechanism is optical transition radiation (OTR), which may be significant in aerogels due to the large number of transitions from SiO2 clusters to vacuum voids. To examine whether OTR is a problem, four aerogel samples were tested using a mono-energetic electron beam (varied in the range of 1-3 MeV) at NSTec Los Alamos Operations. It was demonstrated that aerogels can be used as a Cherenkov medium, where the rate of the light production is about two orders magnitude higher when the electron beam energy is above threshold.

  7. Relativistic ejecta from X-ray flash XRF 060218 and the rate of cosmic explosions.

    Science.gov (United States)

    Soderberg, A M; Kulkarni, S R; Nakar, E; Berger, E; Cameron, P B; Fox, D B; Frail, D; Gal-Yam, A; Sari, R; Cenko, S B; Kasliwal, M; Chevalier, R A; Piran, T; Price, P A; Schmidt, B P; Pooley, G; Moon, D-S; Penprase, B E; Ofek, E; Rau, A; Gehrels, N; Nousek, J A; Burrows, D N; Persson, S E; McCarthy, P J

    2006-08-31

    Over the past decade, long-duration gamma-ray bursts (GRBs)--including the subclass of X-ray flashes (XRFs)--have been revealed to be a rare variety of type Ibc supernova. Although all these events result from the death of massive stars, the electromagnetic luminosities of GRBs and XRFs exceed those of ordinary type Ibc supernovae by many orders of magnitude. The essential physical process that causes a dying star to produce a GRB or XRF, and not just a supernova, is still unknown. Here we report radio and X-ray observations of XRF 060218 (associated with supernova SN 2006aj), the second-nearest GRB identified until now. We show that this event is a hundred times less energetic but ten times more common than cosmological GRBs. Moreover, it is distinguished from ordinary type Ibc supernovae by the presence of 10(48) erg coupled to mildly relativistic ejecta, along with a central engine (an accretion-fed, rapidly rotating compact source) that produces X-rays for weeks after the explosion. This suggests that the production of relativistic ejecta is the key physical distinction between GRBs or XRFs and ordinary supernovae, while the nature of the central engine (black hole or magnetar) may distinguish typical bursts from low-luminosity, spherical events like XRF 060218.

  8. Soft X-Ray Thomson Scattering in Warm Dense Hydrogen at FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Faustlin, R R; Toleikis, S; Bornath, T; Doppner, T; Dusterer, S; Forster, E; Fortmann, C; Glenzer, S H; Gode, S; Gregori, G; Irsig, R; Laarmann, T; Lee, H J; Li, B; Meiwes-Broer, K; Mithen, J; Przystawik, A; Redlin, H; Redmer, R; Reinholz, H; Ropke, G; Tavella, F; Thiele, R; Tiggesbaumker, J; Uschmann, I; Zastrau, U; Tschentscher, T

    2009-07-15

    We present collective Thomson scattering with soft x-ray free electron laser radiation as a method to track the evolution of warm dense matter plasmas with {approx}200 fs time resolution. In a pump-probe scheme an 800 nm laser heats a 20 {micro}m hydrogen droplet to the plasma state. After a variable time delay in the order of ps the plasma is probed by an x-ray ultra violet (XUV) pulse which scatters from the target and is recorded spectrally. Alternatively, in a self-Thomson scattering experiment, a single XUV pulse heats the target while a portion of its photons are being scattered probing the target. From such inelastic x-ray scattering spectra free electron temperature and density can be inferred giving insight on relaxation time scales in plasmas as well as the equation of state. We prove the feasibility of this method in the XUV range utilizing the free electron laser facility in Hamburg, FLASH. We recorded Thomson scattering spectra for hydrogen plasma, both in the self-scattering and in the pump-probe mode using optical laser heating.

  9. Reproducibility of standing posture for X-ray radiography: a feasibility study of the BalancAid with healthy young subjects

    NARCIS (Netherlands)

    Dewi, Dyah Ekashanti Octorina; Veldhuizen, Albert G.; Burgerhof, Johannes G.M.; Purnama, I Ketut Eddy; Ooijen, van Peter M.A.; Wilkinson, Michael H.F.; Mengko, Tati Latifah Erawati Rajab; Verkerke, Gijsbertus J.

    2010-01-01

    Unreliable spinal X-ray radiography measurement due to standing postural variability can be minimized by using positional supports. In this study, we introduce a balancing device, named BalancAid, to position the patients in a reproducible position during spinal X-ray radiography. This study aimed t

  10. Reproducibility of Standing Posture for X-Ray Radiography : A Feasibility Study of the BalancAid with Healthy Young Subjects

    NARCIS (Netherlands)

    Dewi, Dyah Ekashanti Octorina; Veldhuizen, Albert G.; Burgerhof, Johannes G.M.; Purnama, I Ketut Eddy; Ooijen, Peter M.A. van; Wilkinson, Michael H.F.; Mengko, Tati Latifah Erawati Rajab; Verkerke, Gijsbertus Jacob

    2010-01-01

    Unreliable spinal X-ray radiography measurement due to standing postural variability can be minimized by using positional supports. In this study, we introduce a balancing device, named BalancAid, to position the patients in a reproducible position during spinal X-ray radiography. This study aimed t

  11. Reproducibility of Standing Posture for X-Ray Radiography : A Feasibility Study of the BalancAid with Healthy Young Subjects

    NARCIS (Netherlands)

    Dewi, Dyah Ekashanti Octorina; Veldhuizen, Albert G.; Burgerhof, Johannes G.M.; Purnama, I Ketut Eddy; Ooijen, Peter M.A. van; Wilkinson, Michael H.F.; Mengko, Tati Latifah Erawati Rajab; Verkerke, Gijsbertus Jacob

    2010-01-01

    Unreliable spinal X-ray radiography measurement due to standing postural variability can be minimized by using positional supports. In this study, we introduce a balancing device, named BalancAid, to position the patients in a reproducible position during spinal X-ray radiography. This study aimed

  12. Reproducibility of standing posture for X-ray radiography: a feasibility study of the BalancAid with healthy young subjects

    NARCIS (Netherlands)

    Dewi, Dyah Ekashanti Octorina; Veldhuizen, Albert G.; Burgerhof, Johannes G.M.; Purnama, I Ketut Eddy; van Ooijen, Peter M.A.; Wilkinson, Michael H.F.; Mengko, Tati Latifah Erawati Rajab; Verkerke, Gijsbertus Jacob

    2010-01-01

    Unreliable spinal X-ray radiography measurement due to standing postural variability can be minimized by using positional supports. In this study, we introduce a balancing device, named BalancAid, to position the patients in a reproducible position during spinal X-ray radiography. This study aimed

  13. Estimating The Reliability of the Lawrence Livermore National Laboratory (LLNL) Flash X-ray (FXR) Machine

    Energy Technology Data Exchange (ETDEWEB)

    Ong, M M; Kihara, R; Zentler, J M; Kreitzer, B R; DeHope, W J

    2007-06-27

    At Lawrence Livermore National Laboratory (LLNL), our flash X-ray accelerator (FXR) is used on multi-million dollar hydrodynamic experiments. Because of the importance of the radiographs, FXR must be ultra-reliable. Flash linear accelerators that can generate a 3 kA beam at 18 MeV are very complex. They have thousands, if not millions, of critical components that could prevent the machine from performing correctly. For the last five years, we have quantified and are tracking component failures. From this data, we have determined that the reliability of the high-voltage gas-switches that initiate the pulses, which drive the accelerator cells, dominates the statistics. The failure mode is a single-switch pre-fire that reduces the energy of the beam and degrades the X-ray spot-size. The unfortunate result is a lower resolution radiograph. FXR is a production machine that allows only a modest number of pulses for testing. Therefore, reliability switch testing that requires thousands of shots is performed on our test stand. Study of representative switches has produced pre-fire statistical information and probability distribution curves. This information is applied to FXR to develop test procedures and determine individual switch reliability using a minimal number of accelerator pulses.

  14. Pulsed X-ray radiography of a gas jet target for laser-matter interaction experiments with the use of a CCD detector

    Energy Technology Data Exchange (ETDEWEB)

    Rakowski, R. [Institute of Optoelectronics, Military University of Technology, 2 Kaliskiego Street, 00-908 Warsaw (Poland); Bartnik, A. [Institute of Optoelectronics, Military University of Technology, 2 Kaliskiego Street, 00-908 Warsaw (Poland); Fiedorowicz, H. [Institute of Optoelectronics, Military University of Technology, 2 Kaliskiego Street, 00-908 Warsaw (Poland)]. E-mail: hfiedorowicz@wat.edu.pl; Jarocki, R. [Institute of Optoelectronics, Military University of Technology, 2 Kaliskiego Street, 00-908 Warsaw (Poland); Kostecki, J. [Institute of Optoelectronics, Military University of Technology, 2 Kaliskiego Street, 00-908 Warsaw (Poland); MikoIajczyk, J. [Institute of Optoelectronics, Military University of Technology, 2 Kaliskiego Street, 00-908 Warsaw (Poland); Szczurek, A. [Institute of Optoelectronics, Military University of Technology, 2 Kaliskiego Street, 00-908 Warsaw (Poland); Szczurek, M. [Institute of Optoelectronics, Military University of Technology, 2 Kaliskiego Street, 00-908 Warsaw (Poland); Foeldes, I.B. [KFKI-Research Institute for Particle and Nuclear Physics, Association EURATOM, P.O. Box 49, H-1525 Budapest (Hungary); Toth, Zs. [Department of Optics and Quantum Electronics, University of Szeged, H-6701 Szeged, Pf.: 406 (Hungary)

    2005-10-01

    Characterization of gas jet targets has been carried out using pulsed X-ray radiography. A laser-plasma X-ray source was applied for backlighting of the targets to obtain X-ray shadowgraphs registered with a CCD detector. From the shadowgraphs, characteristics of the targets were determined.

  15. A compact micro-beam system using a tapered glass capillary for proton-induced X-ray radiography

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, Jun [Research Laboratory for Nuclear Reactors, Tokyo Institute of Technology, 2-12-1 Ookayama, Meguro-ku, Tokyo 152-8550 (Japan)], E-mail: jhasegaw@nr.titech.ac.jp; Shiba, Shigeki; Fukuda, Hitoshi; Oguri, Yoshiyuki [Research Laboratory for Nuclear Reactors, Tokyo Institute of Technology, 2-12-1 Ookayama, Meguro-ku, Tokyo 152-8550 (Japan)

    2008-05-15

    A compact micro-beam system, containing a tapered glass capillary tube with a tip diameter on the order of 10 {mu}m, was constructed to examine the applicability of capillary-generated micro-beams to high-contrast radiography based on proton-induced quasi-monochromatic X-rays. The transport efficiency of swift protons (2-3 MeV) through the capillary was examined as a function of the capillary tilt angle and the capillary tip diameter. We obtained transport efficiencies of approximately three times larger than would be expected from the geometrical shape of the capillary. This enhancement indicates that a focusing effect occurred in the capillary. A metallic thin foil was irradiated with the micro-beam and quasi-monochromatic X-rays were produced. By calculating the X-ray yields induced by proton bombardment in the foil and comparing them with the X-ray counts observed at the detector, the throughput efficiency of the X-ray imaging system was evaluated. We demonstrated magnification radiography of a small object to show that a spatial resolution on the order of 10 {mu}m was achievable in our system.

  16. X-ray Flashes Powered by the Spindown of Long-lived Neutron Stars

    Science.gov (United States)

    Ciolfi, Riccardo

    2016-10-01

    X-ray flashes (XRFs) are a class of high-energy transients whose nature is still open to question. Similar in many aspects to common gamma-ray bursts (GRBs), their strong X-ray emission is accompanied by very low or absent emission in the gamma-ray band. Despite this key difference, a number of indications have consolidated the idea that XRFs and GRBs share a common origin, including a number of potential XRF/supernova associations and the consistency of some XRFs with the Amati relation for long GRBs. However, the difficulties in explaining XRFs as off-axis or intrinsically weak GRBs still cast doubts on this interpretation. Here we explore the possibility that some XRFs are instead powered by the spindown of a long-lived neutron star (NS) formed in a binary NS (BNS) merger or, possibly, in a core-collapse supernova. Focusing on XRF 020903 and a few other cases observed by HETE-2, we show that their lack of gamma-ray emission, spectral properties, duration and X-ray luminosity find a natural explanation within our hypothesis. Moreover, we point out that the agreement of XRF 020903 with the Amati and Ghirlanda relations for long GRBs is respectively only marginal and problematic. Assuming a BNS merger origin for the long-lived NS, we use XRF observations to estimate a lower limit on the rate of BNS mergers accompanied by a potentially observable XRF signal. Within the reach of the advanced LIGO and Virgo gravitational wave detectors, we find \\gt 0.02{--}0.05 {{yr}}-1. Finally, we discuss the implications of a supernova association for the XRF events considered.

  17. Optical, Infrared, and Ultraviolet Observations of the X-Ray Flash GRB 050416A

    CERN Document Server

    Holland, S T; Gorosabel, J; Hjorth, J; Schady, P; Thomsen, B; Augusteijn, T; Blustin, A J; Breeveld, A; De Pasquale, M; Fynbo, J P U; Gehrels, N; Gronwall, C; Hunsberger, S; Ivanushkina, M; Landsman, W B; Laursen, P; McGowan, K; Mangano, V; Markwardt, C B; Marshall, F; Mason, K O; Moretti, A; Page, M J; Poole, T; Roming, P; Rosen, S; Still, M

    2006-01-01

    We present ultraviolet, optical, and infrared photometry of the afterglow of the X-ray flash GRB 050416A taken between approximately 100 seconds and 36 days after the burst. We find an intrinsic spectral slope between 1930 Angstrom and 22,200 Angstrom of -1.14 +/- 0.20 and a decay rate of -0.86 +/- 0.15. There is no evidence for a change in the decay rate between approximately 0.7 and 4.7 days after the burst. Our data implies that there is no spectral break between the optical and X-ray bands between 0.7 and 4.7 days after the burst, and is consistent with the cooling break being redward of the K_s band (22,200 Angstrom) at 0.7 days. The combined ultraviolet/optical/infrared spectral energy distribution shows no evidence for a significant amount of extinction in the host galaxy along the line of sight to GRB 050416A. Our data suggest that the extragalactic extinction along the line of sight to the burst is only approximately A_V = 0.2 mag, which is significantly less than the extinction expected from the hyd...

  18. Extremely Soft X-ray Flash as the indicator of off-axis orphan GRB afterglow

    CERN Document Server

    Urata, Yuji; Yamazaki, Ryo; Sakamoto, Takanori

    2015-01-01

    We verified the off-axis jet model of X-ray flashes (XRFs) and examined a discovery of off-axis orphan gamma-ray burst (GRBs) afterglows. The XRF sample was selected on the basis of the following three factors: (1) a constraint on the lower peak energy of the prompt spectrum $E^{src}_{obs}$, (2) redshift measurements, and (3) multi-color observations of an earlier (or brightening) phase. XRF020903 was the only sample selected basis of these criteria. A complete optical multi-color afterglow light curve of XRF020903 obtained from archived data and photometric results in literature showed an achromatic brightening around 0.7 days. An off-axis jet model with a large observing angle (0.21 rad, which is twice the jet opening half-angle, $\\theta_{jet}$) can naturally describe the achromatic brightening and the prompt X-ray spectral properties. This result indicates the existence of off-axis orphan GRB afterglow light curves. Events with a larger viewing angle ($>\\sim2\\theta_{jet}$) could be discovered using an 8-m ...

  19. Afterglow Observations Shed New Light on the Nature of X-ray Flashes

    CERN Document Server

    Granot, J; Perna, R; Granot, Jonathan; Ramirez-Ruiz, Enrico; Perna, Rosalba

    2005-01-01

    X-ray flashes (XRFs) and X-ray rich gamma-ray bursts (XRGRBs) share many observational characteristics with long duration GRBs, but the reason for which their prompt emission peaks at lower photon energies, $E_p$, is still under debate. Although many different models have been invoked in order to explain the lower $E_p$ values, their implications for the afterglow emission were not considered in most cases, mainly because observations of XRF afterglows have become available only recently. Here we examine the predictions of the various XRF models for the afterglow emission, and test them against the observations of XRF 030723 and XRGRB 041006, the events with the best monitored afterglow light curves in their respective class. We show that most existing XRF models are hard to reconcile with the observed afterglow light curves, which are very flat at early times. Such light curves are, however, naturally produced by a roughly uniform jet with relatively sharp edges that is viewed off-axis (i.e. from outside of ...

  20. Visualization of neonatal lung injury associated with mechanical ventilation using x-ray dark-field radiography

    Science.gov (United States)

    Yaroshenko, Andre; Pritzke, Tina; Koschlig, Markus; Kamgari, Nona; Willer, Konstantin; Gromann, Lukas; Auweter, Sigrid; Hellbach, Katharina; Reiser, Maximilian; Eickelberg, Oliver; Pfeiffer, Franz; Hilgendorff, Anne

    2016-04-01

    Mechanical ventilation (MV) and supplementation of oxygen-enriched gas, often needed in postnatal resuscitation procedures, are known to be main risk factors for impaired pulmonary development in the preterm and term neonates. Unfortunately, current imaging modalities lack in sensitivity for the detection of early stage lung injury. The present study reports a new imaging approach for diagnosis and staging of early lung injury induced by MV and hyperoxia in neonatal mice. The imaging method is based on the Talbot-Lau x-ray grating interferometry that makes it possible to quantify the x-ray small-angle scattering on the air-tissue interfaces. This so-called dark-field signal revealed increasing loss of x-ray small-angle scattering when comparing images of neonatal mice undergoing hyperoxia and MV-O2 with animals kept at room air. The changes in the dark field correlated well with histologic findings and provided superior differentiation than conventional x-ray imaging and lung function testing. The results suggest that x-ray dark-field radiography is a sensitive tool for assessing structural changes in the developing lung. In the future, with further technical developments x-ray dark-field imaging could be an important tool for earlier diagnosis and sensitive monitoring of lung injury in neonates requiring postnatal oxygen or ventilator therapy.

  1. Characterisation of Late Bronze Age large size shield nails by EDXRF, micro-EDXRF and X-ray digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Figueiredo, E., E-mail: elin@itn.pt [Instituto Tecnologico e Nuclear, Estrada Nacional 10, 2686-953 Sacavem (Portugal); CENIMAT/I3N, Departamento de Ciencia dos Materiais, Faculdade de Ciencias e Tecnologia, Universidade Nova de Lisboa, 2829-516 Monte de Caparica (Portugal); Departamento de Conservacao e Restauro, Faculdade de Ciencias e Tecnologia, Universidade Nova de Lisboa, 2829-516 Monte de Caparica (Portugal); Araujo, M.F. [Instituto Tecnologico e Nuclear, Estrada Nacional 10, 2686-953 Sacavem (Portugal); Silva, R.J.C. [CENIMAT/I3N, Departamento de Ciencia dos Materiais, Faculdade de Ciencias e Tecnologia, Universidade Nova de Lisboa, 2829-516 Monte de Caparica (Portugal); Senna-Martinez, J.C. [Centro de Arqueologia (Uniarq), Faculdade de Letras, Universidade de Lisboa, 1600-214 Lisboa (Portugal); Ines Vaz, J.L. [Departamento de Letras, Universidade Catolica, Estrada da Circunvalacao, 3504-505 Viseu (Portugal)

    2011-09-15

    In the present study six exceptional large size metallic nails, a dagger and a sickle from the Late Bronze Age archaeological site of Figueiredo das Donas (Central Portugal) have been analysed by EDXRF, micro-EDXRF and X-ray digital radiography for the study of material composition and technology of fabrication. The combination of these analytical and examination techniques showed that all artefacts are made of bronze with As, Sb and Pb impurities, and that the nails were most likely manufactured using the casting-on technique. These results reinforce the use of binary bronze by Late Bronze Age in the region, and the incorporation of new fabrication technologies that resulted from ancient spheres of interaction. - Highlights: > EDXRF, micro-EDXRF and X-ray digital radiography in cultural heritage studies. > Archaeometallurgical study of a Late Bronze Age artefact collection from Portugal. > Practise of a specific and traditional bronze metallurgy. > Appearance of technological innovations as the casting-on technique.

  2. Interpretation of Core Length in Shear Coaxial Rocket Injectors from X-ray Radiography Measurements (Briefing Charts)

    Science.gov (United States)

    2014-06-01

    Shear Coaxial Rocket Injectors from X-ray Radiography Measurements 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT...ASE/ASEE Joint Propulsion Conference, Cleveland, OH, 29 July 2014. PA#14365 14. ABSTRACT Shear coaxial injectors are so named because they rely on...DISTRIBUTION A: Approved for public release; distribution unlimited. Clearance #  Interpretation of Core Length in Shear Coaxial Rocket Injectors from

  3. Core Length and Spray Width Measurements in Shear Coaxial Rocket Injectors from X-ray Radiography Measurements

    Science.gov (United States)

    2015-05-01

    combustion applications, such as rockets, this region is also the area of flame holding, and so is of primary im- portance in predicting combustion...spray and dividing by the liquid-mass-flow rate allows a mass-averaged liquid velocity to be calculated . In the recent years x-ray radiography has...efficient, and ρl is the density of the absorbing fluid (in this case demineralized water). The mass attenuation coefficient can be calculated using

  4. Displacement tracking in single human trabecula with metal-plated micro-spheres using X-ray radiography imaging

    Science.gov (United States)

    Jiroušek, O.; Kytýř, D.; Doktor, T.; Dammer, J.; Krejčí, F.

    2013-02-01

    This study presents an improved radiographic method for strain measurement in very small samples of a single trabeculae. X-ray micro-radiography was used to track the deformation behaviour of individual trabecula during mechanical loading. As the X-ray micro-radiography images of a single trabecula show no significant features applicable for digital image correlation (DIC) a random pattern of markers was created on the surfaces of the samples to improve the accuracy of tracking. Metal plated borosilicate glassmicro-spheres (mean diameter 10 μm) were used as the markers for trabecular displacement tracking. Two different X-ray imaging setups were used for this purpose. The specimens of isolated trabeculae were loaded by a micro-mechanical testing device developed with respect to radiographical observation. This compact device enables a high precision three-point bending measurement. The specimen was continuously irradiated during the loading procedure by a micro-focus X-ray source. The radiographs were acquired by a single-photon counting silicon pixel detector and s flat panel sensor with CsI flipped scintillator plate. Circular Hough transform was used to locate positions of the spherical markers in the sequence of acquired radiographs and to calculate the strain in the loaded sample. The gold-coated micro-spheres provide clearly visible features in the sequence of radiographs after beam hardening correction, which in conjunction with pattern recognition algorithm enables to substantially improve the accuracy of strain measurements.

  5. Investigation of time-resolved proton radiography using x-ray flat-panel imaging system

    Science.gov (United States)

    Jee, K.-W.; Zhang, R.; Bentefour, E. H.; Doolan, P. J.; Cascio, E.; Sharp, G.; Flanz, J.; Lu, H.-M.

    2017-03-01

    Proton beam therapy benefits from the Bragg peak and delivers highly conformal dose distributions. However, the location of the end-of-range is subject to uncertainties related to the accuracy of the relative proton stopping power estimates and thereby the water-equivalent path length (WEPL) along the beam. To remedy the range uncertainty, an in vivo measurement of the WEPL through the patient, i.e. a proton-range radiograph, is highly desirable. Towards that goal, we have explored a novel method of proton radiography based on the time-resolved dose measured by a flat panel imager (FPI). A 226 MeV pencil beam and a custom-designed range modulator wheel (MW) were used to create a time-varying broad beam. The proton imaging technique used exploits this time dependency by looking at the dose rate at the imager as a function of time. This dose rate function (DRF) has a unique time-varying dose pattern at each depth of penetration. A relatively slow rotation of the MW (0.2 revolutions per second) and a fast image acquisition (30 frames per second, ~33 ms sampling) provided a sufficient temporal resolution for each DRF. Along with the high output of the CsI:Tl scintillator, imaging with pixel binning (2  ×  2) generated high signal-to-noise data at a very low radiation dose (~0.1 cGy). Proton radiographs of a head phantom and a Gammex CT calibration phantom were taken with various configurations. The results of the phantom measurements show that the FPI can generate low noise and high spatial resolution proton radiographs. The WEPL values of the CT tissue surrogate inserts show that the measured relative stopping powers are accurate to ~2%. The panel did not show any noticeable radiation damage after the accumulative dose of approximately 3831 cGy. In summary, we have successfully demonstrated a highly practical method of generating proton radiography using an x-ray flat panel imager.

  6. Local liquid velocity measurement of Trickle Bed Reactor using Digital Industrial X-ray Radiography

    Science.gov (United States)

    Mohd Salleh, Khairul Anuar

    Trickle Bed Reactors (TBRs) are fixed beds of particles in which both liquid and gas flow concurrently downward. They are widely used to produce not only fuels but also lubrication products. The measurement and the knowledge of local liquid velocities (VLL) in TBRs is less which is essential for advancing the understanding of its hydrodynamics and for validation computational fluid dynamics (CFD). Therefore, this work focused on developing a new, non-invasive, statistically reliable technique that can be used to measure local liquid velocity (VLL) in two-dimensions (2-D). This is performed by combining Digital Industrial X-ray Radiography (DIR) and Particle Tracking Velocimetry (PTV) techniques. This work also make possible the development of three-dimensional (3-D) VLL measurements that can be taken in TBRs. Measurements taken through both the combined and the novel technique, once validated, were found to be comparable to another technique (a two-point fiber optical probe) currently being developed at Missouri University of Science and Technology. The results from this study indicate that, for a gas-liquid-solid type bed, the measured VLL can have a maximum range that is between 35 and 51 times that of its superficial liquid velocity (VSL). Without the existence of gas, the measured VLL can have a maximum range that is between 4 and 4.7 times that of its VSL. At a higher V SL, the particle tracer was greatly distributed and became carried away by a high liquid flow rate. Neither the variance nor the range of measured VLL varied for any of the replications, confirming the reproducibility of the experimental measurements used, regardless of the VSL . The liquid's movement inside the pore was consistent with findings from previous studies that used various techniques.

  7. Improved In vivo Assessment of Pulmonary Fibrosis in Mice using X-Ray Dark-Field Radiography

    Science.gov (United States)

    Yaroshenko, Andre; Hellbach, Katharina; Yildirim, Ali Önder; Conlon, Thomas M.; Fernandez, Isis Enlil; Bech, Martin; Velroyen, Astrid; Meinel, Felix G.; Auweter, Sigrid; Reiser, Maximilian; Eickelberg, Oliver; Pfeiffer, Franz

    2015-12-01

    Idiopathic pulmonary fibrosis (IPF) is a chronic and progressive lung disease with a median life expectancy of 4-5 years after initial diagnosis. Early diagnosis and accurate monitoring of IPF are limited by a lack of sensitive imaging techniques that are able to visualize early fibrotic changes at the epithelial-mesenchymal interface. Here, we report a new x-ray imaging approach that directly visualizes the air-tissue interfaces in mice in vivo. This imaging method is based on the detection of small-angle x-ray scattering that occurs at the air-tissue interfaces in the lung. Small-angle scattering is detected with a Talbot-Lau interferometer, which provides the so-called x-ray dark-field signal. Using this imaging modality, we demonstrate-for the first time-the quantification of early pathogenic changes and their correlation with histological changes, as assessed by stereological morphometry. The presented radiography method is significantly more sensitive in detecting morphological changes compared with conventional x-ray imaging, and exhibits a significantly lower radiation dose than conventional x-ray CT. As a result of the improved imaging sensitivity, this new imaging modality could be used in future to reduce the number of animals required for pulmonary research studies.

  8. A Compact 5 MeV S-Band Electron Linac Based X-Ray Source for Industrial Radiography

    CERN Document Server

    Auditore, Lucrezia; De Pasquale, Domenico; Emanuele, Umberto; Italiano, Antonio; Trifirò, Antonio; Trimarchi, Marina

    2005-01-01

    A compact and reliable X-ray source, based on a 5 MeV, 1 kW, S-band electron linac, has been set up at the Dipartimento di Fisica, Universit\\'a di Messina. This source, coupled with a GOS scintillator screen and a CCD camera, represents an innovative transportable system for industrial radiography and X-ray tomography. Optimization of the parameters influencing the e-gamma conversion and the X-ray beam characteristics have been studied by means of the MCNP-4C2 code. The converter choice is the result of the study of the e-gamma conversion performances for different materials and materials thicknesses. Also the converter position with respect to the linac exit window was studied. The chosen converter consists in a Ta-Cu target inserted close to the linac window. The Cu layer acts as a filter both on the electrons from the source and on the low energy X-rays. The X-ray beam angular profile was studied by means of GafChromic films with and without collimation. In the final source project, a collimation system pr...

  9. Complementary X-ray and neutron radiography study of the initial lithiation process in lithium-ion batteries containing silicon electrodes

    Science.gov (United States)

    Sun, Fu; Markötter, Henning; Manke, Ingo; Hilger, André; Alrwashdeh, Saad S.; Kardjilov, Nikolay; Banhart, John

    2017-03-01

    Complementary in operando X-ray radiography and neutron radiography measurements were conducted to investigate and visualize the initial lithiation in silicon-electrode lithium-ion batteries. By means of X-ray radiography, a significant volume expansion of Si particles and the Si electrode during the first discharge was observed. In addition, many Si particles were found that never undergo electrochemical reactions. These findings were confirmed by neutron radiography, which, for the first time, showed the process of Li alloying with the Si electrode during initial lithiation. These results demonstrate that complementary X-ray and neutron radiography is a powerful tool to investigate the lithiation mechanisms inside Si-electrode based lithium-ion batteries.

  10. Detection of Subsurface Defects Using X-Ray Lateral Migration Radiography - A New Backscatter Imaging Technique

    Energy Technology Data Exchange (ETDEWEB)

    Edward T. Dugan; Alan M. Jacobs

    2003-02-10

    A new Compton X-ray backscatter imaging technique called lateral migration radiography (LMR) is applied to detecting a class of sub-surface defects in materials and structures of industrial importance. These include flaws and defects for which there is either no known method or an effective method for detection. Examples are delamination in layered composite structures, defects in deposited coatings on metal surfaces such as in aircraft jet engine components and geometrical structural/composition changes (e.g. due to corrosion) on the inside of shell-like components with only outside surface area access.Research efforts include: the construction of simulated flawed test objects on which experimental measurements are performed to establish LMR flaw detection capabilities; performance of Monte Carlo simulations of these measurements to assist in predicting optimum source-detector configurations and to help obtain a detailed understanding of the physics of lateral migration in small voids and how this impacts the resulting LMR image contrasts; the procurement of samples of materials of industrial importance with flaws and defects; the application of LMR to the detection of flaws and defects in these samples; the development of a multi-detector scanning system to provide for faster, more effective flaw detection; and a determination, for the types of samples examined, of the limits and capabilities of flaw detection using LMR.LMR imaging measurements on the machined samples showed that the optimum contrast in flaw-to-background signal intensity occurred at an X-ray energy of 75 kVp for the aluminum samples and at 35 kVp for the Delrin sample. Monte Carlo simulations and experimental measurements on the aluminum samples showed that LMR is capable of detecting defects down to the tens of microns range. Measurements on the aluminum samples also showed that LMR is capable of detecting relatively small composition variations; a 30 % difference in image intensity was

  11. The thermonuclear-flash model for X-ray burst sources - A new tool for observing neutron stars

    Science.gov (United States)

    Joss, P. C.

    1979-01-01

    The helium-flash model for X-ray burst sources, in which matter is presumed to accrete onto the surface of a neutron star, is discussed. Attention is given to the accretion process, nuclear burning, X-ray emission, and the energy released by convection as well as by radiative diffusion near the surface. The rise times of observed bursts, their spectral evolution, and the properties of the spectrally soft X-ray transients are considered. Problems in interpreting the continuum spectra are discussed, along with problems in the detection and measurement of line features in the spectra. Also considered are the ratio of time-averaged persistent luminosity to time-averaged burst luminosity, peak burst luminosities, and the possibility of detecting binary membership for burst sources.

  12. Collimated Jet Or Expanding Outflow: Possible Origins of GRBs And X-Ray Flashes

    Energy Technology Data Exchange (ETDEWEB)

    Mizuta, Akira; /Kyoto U., Yukawa Inst., Kyoto /Garching, Max Planck Inst.; Yamasaki, Tatsuya; /Kyoto U., Yukawa Inst., Kyoto; Nagataki, Shigehiro; /Kyoto U., Yukawa Inst.,; Mineshige, Shin; /Kyoto U., Yukawa Inst., Kyoto

    2006-08-10

    transition between the GRBs, X-ray rich GRBs (XRRs) and X-ray Flashes (XRFs) by the same model but with different {epsilon}{sub 0} values.

  13. First results of KALI-30 GW with 1 MV flash X-rays generation and characterization by Imaging plate

    Science.gov (United States)

    Sharma, A.; Shaikh, A. M.; Senthil, K.; Mitra, S.; Chandra, R.; Vishnu, S.; Sandeep, S.; Roy, A.; Rakhee, M.; Sharma, V.; Danish, M. B.; Kolge, T. S.; Ranjeet, K.; Agrawal, R.; Saroj, P. C.; Tewari, S. V.; Mittal, K. C.

    2014-07-01

    The design, development and commissioning of 1 MV pulsed electron accelerator producing Flash X-Rays is described in this paper. This pulsed power system is based on bipolar MARX generator and Blumlein followed by Explosive electron emission diode assembly. The peak pulsed power is ~ 30 GW. The electron energies in the range of 400 keV to 1030 keV are produced and delivered to experimental load of Industrial diode. Electrons are emitted from a stainless steel ring at ground potential by explosive field emission and bombard the anode tungsten pin for flash X-rays generation. The relativistic electron beam has been simulated within the diode chamber and pattern shows the beam propagation. Imaging plates are used to characterize the source size and optimization has been reported.

  14. Spot size measurement of flash-radiography source utilizing the pinhole imaging method

    CERN Document Server

    Wang, Yi; Chen, Nan; Cheng, Jinming; Xie, Yutong; Liu, Yulong; Long, Quanhong

    2015-01-01

    The spot size of the x-ray source is a key parameter of a flash-radiography facility, which is usually quoted as an evaluation of the resolving power. The pinhole imaging technique is applied to measure the spot size of the Dragon-I linear induction accelerator, by which a two-dimensional spatial distribution of the source spot is obtained. Experimental measurements are performed to measure the spot image when the transportation and focusing of the electron beam is tuned by adjusting the currents of solenoids in the downstream section. The spot size of full-width at half maximum and that defined from the spatial frequency at half peak value of the modulation transfer function are calculated and discussed.

  15. Spot size measurement of a flash-radiography source using the pinhole imaging method

    Science.gov (United States)

    Wang, Yi; Li, Qin; Chen, Nan; Cheng, Jin-Ming; Xie, Yu-Tong; Liu, Yun-Long; Long, Quan-Hong

    2016-07-01

    The spot size of the X-ray source is a key parameter of a flash-radiography facility, and is usually quoted as an evaluation of the resolving power. The pinhole imaging technique is applied to measure the spot size of the Dragon-I linear induction accelerator, by which a two-dimensional spatial distribution of the source spot is obtained. Experimental measurements are performed to measure the spot image when the transportation and focusing of the electron beam are tuned by adjusting the currents of solenoids in the downstream section. The spot size of full-width at half maximum and that defined from the spatial frequency at half peak value of the modulation transfer function are calculated and discussed.

  16. Quantitative studies on inner interfaces in conical metal joints using hard x-ray inline phase contrast radiography

    Science.gov (United States)

    Zabler, S.; Rack, T.; Rack, A.; Nelson, K.

    2010-10-01

    Quantitative investigation of micrometer and submicrometer gaps between joining metal surfaces is applied to conical plug-socket connections in dental titanium implants. Microgaps of widths well beyond the resolving power of industrial x-ray systems are imaged by synchrotron phase contrast radiography. Furthermore, by using an analytical model for the relatively simple sample geometry and applying it to numerical forward simulations of the optical Fresnel propagation, we show that quantitative measurements of the microgap width down to 0.1 μm are possible. Image data recorded at the BAMline (BESSY-II light source, Germany) are presented, with the resolving power of the imaging system being 4 μm in absorption mode and ˜14 μm in phase contrast mode (z2=0.74 m). Thus, phase contrast radiography, combined with numerical forward simulations, is capable of measuring the widths of gaps that are two orders of magnitude thinner than the conventional detection limit.

  17. Experimental study of self magnetic pinch diode as flash radiography source at 4 megavolt

    Energy Technology Data Exchange (ETDEWEB)

    Etchessahar, Bertrand; Bicrel, Béatrice; Cassany, Bruno; Desanlis, Thierry; Voisin, Luc [CEA, DAM, CESTA—F-33114 Le Barp (France); Maisonny, Rémi; Toury, Martial; Hourdin, Laurent; Cartier, Frédéric; Cartier, Stéphanie; D' Almeida, Thierry; Delbos, Christophe; Garrigues, Alain; Plouhinec, Damien; Ritter, Sandra; Sol, David; Zucchini, Frédéric; Caron, Michel [CEA, DAM, GRAMAT—F-46500 Gramat (France)

    2013-10-15

    The Self Magnetic Pinch (SMP) diode is a potential high-brightness X-ray source for high voltage generators (2–10 MV) that has shown good reliability for flash radiography applications [D. D. Hinchelwood et al., “High power self-pinch diode experiments for radiographic applications” IEEE Trans. Plasma Sci. 35(3), 565–572 (2007)]. We have studied this diode at about 4 MV, driven by the ASTERIX generator operated at the CEA/GRAMAT [G. Raboisson et al., “ASTERIX, a high intensity X-ray generator,” in Proceedings of the 7th IEEE Pulsed Power Conference (1989), pp. 567–570]. This generator, made up of a capacitor bank and a Blumlein line, was initially designed to test the behavior of electronic devices under irradiation. In our experiments, the vacuum diode is modified in order to set up flash radiographic diodes. A previous set of radiographic experiments was carried out on ASTERIX with a Negative Polarity Rod Pinch (NPRP) diode [B. Etchessahar et al., “Study and optimization of negative polarity rod pinch diode as flash radiography source at 4.5 MV,” Phys. Plasmas 19(9), 093104 (2012)]. The SMP diode which is examined in the present study provides an alternative operating point on the same generator and a different radiographic performance: 142 ± 11 rad at 1 m dose (Al) for a 3.46 ± 0.42 mm spot size (1.4× FWHM of the LSF). This performance is obtained in a reproducible and robust nominal configuration. However, several parametric variations were also tested, such as cathode diameter and anode/cathode gap. They showed that an even better performance is accessible after optimization, in particular, a smaller spot size (<3 mm). Numbers of electrical, optical, and X-ray diagnostics have been implemented in order to gain more insight in the diode physics and to optimize it further. For the first time in France, visible and laser imaging of the SMP diode has been realized, from a radial point of view, thus, providing key information on the electrode

  18. Experimental study of self magnetic pinch diode as flash radiography source at 4 megavolt

    Science.gov (United States)

    Etchessahar, Bertrand; Maisonny, Rémi; Toury, Martial; Hourdin, Laurent; Bicrel, Béatrice; Cassany, Bruno; Desanlis, Thierry; Voisin, Luc; Cartier, Frédéric; Cartier, Stéphanie; D'Almeida, Thierry; Delbos, Christophe; Garrigues, Alain; Plouhinec, Damien; Ritter, Sandra; Sol, David; Zucchini, Frédéric; Caron, Michel

    2013-10-01

    The Self Magnetic Pinch (SMP) diode is a potential high-brightness X-ray source for high voltage generators (2-10 MV) that has shown good reliability for flash radiography applications [D. D. Hinchelwood et al., "High power self-pinch diode experiments for radiographic applications" IEEE Trans. Plasma Sci. 35(3), 565-572 (2007)]. We have studied this diode at about 4 MV, driven by the ASTERIX generator operated at the CEA/GRAMAT [G. Raboisson et al., "ASTERIX, a high intensity X-ray generator," in Proceedings of the 7th IEEE Pulsed Power Conference (1989), pp. 567-570]. This generator, made up of a capacitor bank and a Blumlein line, was initially designed to test the behavior of electronic devices under irradiation. In our experiments, the vacuum diode is modified in order to set up flash radiographic diodes. A previous set of radiographic experiments was carried out on ASTERIX with a Negative Polarity Rod Pinch (NPRP) diode [B. Etchessahar et al., "Study and optimization of negative polarity rod pinch diode as flash radiography source at 4.5 MV," Phys. Plasmas 19(9), 093104 (2012)]. The SMP diode which is examined in the present study provides an alternative operating point on the same generator and a different radiographic performance: 142 ± 11 rad at 1 m dose (Al) for a 3.46 ± 0.42 mm spot size (1.4× FWHM of the LSF). This performance is obtained in a reproducible and robust nominal configuration. However, several parametric variations were also tested, such as cathode diameter and anode/cathode gap. They showed that an even better performance is accessible after optimization, in particular, a smaller spot size (<3 mm). Numbers of electrical, optical, and X-ray diagnostics have been implemented in order to gain more insight in the diode physics and to optimize it further. For the first time in France, visible and laser imaging of the SMP diode has been realized, from a radial point of view, thus, providing key information on the electrode plasmas evolution

  19. X-ray inspection of large LSAW pipes using modern filmless radiography; Moderne Roentgenpruefung mittels filmloser Radiographie an LSAW Grossrohren

    Energy Technology Data Exchange (ETDEWEB)

    Kersting, Thomas; Liessem, Andreas; Oesterlein, Ludwig; Schuster, Stefan [EUROPIPE, Muelheim a.d. Ruhr (Germany); Schoenartz, Norbert [Salzgitter Mannesmann Forschung, Duisburg (Germany)

    2008-07-01

    Large-diameter pipes with longitudinal welds for transporting combustible media are subject to the most rigid safety specifications. For further improvement of the nondestructive testing process, EUROPIPE - the market leader in the field of large-diameter pipes for the oil and gas industry - invested in digital radiographic inspection, which completely replaces classic X-ray films. The new system comprises two separate X-ray chambers in order to keep up with the production rate. Each X-ray chamber contains two digital panel detectors and two X-ray tubes. EUROPIPE is one of the first organisations worldwide to introduce this technology in automatic serial production of large-diameter pipes. [German] Fuer laengsnahtgeschweisste Grossrohre zum Transport von brennbaren Medien gelten hoechste Sicherheitsanforderungen. Zur weiteren Verbesserung des zerstoerungsfreien Pruefprozesses hat EUROPIPE als Marktfuehrer fuer Grossrohre der Oel- und Gasindustrie in die digitale Roentgenpruefung investiert und damit komplett den klassischen Roentgenfilm ersetzt. Die neue Anlage besteht aus zwei separaten Roentgenkammern, um die Taktzeiten des Produktionsflusses einhalten zu koennen. In jeder Roentgenkammer befinden sich je zwei digitale Flaechendetektoren und zwei Roentgenroehren. EUROPIPE ist eines der ersten Unternehmen, das diese Technologie in die automatisierte Serienproduktion von Grossrohren eingefuehrt hat.

  20. High-speed, two-dimensional synchrotron white-beam x-ray radiography of spray breakup and atomization.

    Science.gov (United States)

    Halls, Benjamin R; Radke, Christopher D; Reuter, Benjamin J; Kastengren, Alan L; Gord, James R; Meyer, Terrence R

    2017-01-23

    High-speed, two-dimensional synchrotron x-ray radiography and phase-contrast imaging are demonstrated in propulsion sprays. Measurements are performed at the 7-BM beamline at the Advanced Photon Source user facility at Argonne National Laboratory using a recently developed broadband x-ray white beam. This novel enhancement allows for high speed, high fidelity x-ray imaging for the community at large. Quantitative path-integrated liquid distributions and spatio-temporal dynamics of the sprays were imaged with a LuAG:Ce scintillator optically coupled to a high-speed CMOS camera. Images are collected with a microscope objective at frame rates of 20 kHz and with a macro lens at 120 kHz, achieving spatial resolutions of 12 μm and 65 μm, respectively. Imaging with and without potassium iodide (KI) as a contrast-enhancing agent is compared, and the effects of broadband attenuation and spatial beam characteristics are determined through modeling and experimental calibration. In addition, phase contrast is used to differentiate liquid streams with varying concentrations of KI. The experimental approach is applied to different spray conditions, including quantitative measurements of mass distribution during primary atomization and qualitative visualization of turbulent binary fluid mixing.

  1. Study on diffusion behavior and microstructural evolution of Al/Cu bimetal interface by synchrotron X-ray radiography

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Tongmin, E-mail: tmwang@dlut.edu.cn [Key Laboratory of Materials Modification By Laser, Ion and Electron Beams (Ministry of Education), School of Material Science and Engineering, Dalian University of Technology, Dalian 116024 (China); Cao, Fei; Zhou, Peng; Kang, Huijun; Chen, Zongning [Key Laboratory of Materials Modification By Laser, Ion and Electron Beams (Ministry of Education), School of Material Science and Engineering, Dalian University of Technology, Dalian 116024 (China); Fu, Yanan; Xiao, Tiqiao [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201204 (China); Huang, Wanxia; Yuan, Qingxi [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100039 (China)

    2014-12-15

    Highlights: • Interface diffusion of Al/Cu bimetal was directly observed with X-ray radiography. • Three growth stages and four transition zones around Al/Cu interface were identified. • Concentration variations were analyzed through the gray level evolution of images. • Diffusion coefficients of Cu in Al were calculated from concentration variations. - Abstract: Synchrotron X-ray radiography was used to in situ study the interface diffusion behavior and microstructural evolution during the melting and solidification of Al/Cu bimetal. During the solidification, the dendritic growth around the interface is mainly dominated by the variation of Cu concentration and thermal field. Four transition zones of solute profile around the interface were identified to be I (α-Al), II (Al + Al{sub 2}Cu), III (Al{sub 2}Cu) and IV (AlCu, Al{sub 3}Cu{sub 4} and Al{sub 2}Cu{sub 3}), respectively. During the melting, the concentration variations of Al and Cu around the interface were quantitatively analyzed through the extraction of gray level from sequenced X-ray images. The diffusion coefficients of Cu in liquid Al were calculated from the known concentration variations by an inverse method based on Fick’s second law. The diffusion coefficients of Cu in Al were found to follow linear Arrhenius equation dependencies with the pre-exponential factor of 2.83 × 10{sup −5} m{sup 2} s{sup −1} and the activation energy of 96.0 kJ mol{sup −1} in a temperature range of 893–970 K.

  2. Comparison of radiation dose, workflow, patient comfort and financial break-even of standard digital radiography and a novel biplanar low-dose X-ray system for upright full-length lower limb and whole spine radiography

    Energy Technology Data Exchange (ETDEWEB)

    Dietrich, Tobias J.; Pfirrmann, Christian W.A.; Pankalla, Katja; Buck, Florian M. [Orthopedic University Hospital Balgrist, Department of Radiology, Zurich (Switzerland); University of Zurich, Zurich (Switzerland); Schwab, Alexander [University of Zurich, Zurich (Switzerland); Orthopedic University Hospital Balgrist, Department of Finances, Zurich (Switzerland)

    2013-07-15

    To compare the radiation dose, workflow, patient comfort, and financial break-even of a standard digital radiography and a biplanar low-dose X-ray system. A standard digital radiography system (Ysio, Siemens Healthcare, Erlangen, Germany) was compared with a biplanar X-ray unit (EOS, EOS imaging, Paris, France) consisting of two X-ray tubes and slot-scanning detectors, arranged at an angle of 90 allowing simultaneous vertical biplanar linear scanning in the upright patient position. We compared data of standing full-length lower limb radiographs and whole spine radiographs of both X-ray systems. Dose-area product was significantly lower for radiographs of the biplanar X-ray system than for the standard digital radiography system (e.g. whole spine radiographs; standard digital radiography system: 392.2 {+-} 231.7 cGy*cm{sup 2} versus biplanar X-ray system: 158.4 {+-} 103.8 cGy*cm{sup 2}). The mean examination time was significantly shorter for biplanar radiographs compared with standard digital radiographs (e.g. whole spine radiographs: 449 s vs 248 s). Patients' comfort regarding noise was significantly higher for the standard digital radiography system. The financial break-even point was 2,602 radiographs/year for the standard digital radiography system compared with 4,077 radiographs/year for the biplanar X-ray unit. The biplanar X-ray unit reduces radiation exposure and increases subjective noise exposure to patients. The biplanar X-ray unit demands a higher number of examinations per year for the financial break-even point, despite the lower labour cost per examination due to the shorter examination time. (orig.)

  3. X-ray Digital Radiography and Computed Tomography of ICF and HEDP Materials, Subassemblies and Targets

    Energy Technology Data Exchange (ETDEWEB)

    Brown, W D; Martz Jr., H E

    2006-05-31

    Inertial confinement fusion (ICF) and high energy density physics (HEDP) research are being conducted at large laser facilities, such as the University of Rochester's Laboratory for Laser Energetics OMEGA facility and the Lawrence Livermore National Laboratory's (LLNL) National Ignition Facility (NIF). At such facilities, millimeter-sized targets with micrometer structures are studied in a variety of hydrodynamic, radiation transport, equation-of-state, inertial confinement fusion and high-energy density experiments. The extreme temperatures and pressures achieved in these experiments make the results susceptible to imperfections in the fabricated targets. Targets include materials varying widely in composition ({approx}3 < Z < {approx}82), density ({approx}0.03 to {approx}20 g/cm{sup 3}), geometry (planar to spherical) and embedded structures (joints to subassemblies). Fabricating these targets with structures to the tolerances required is a challenging engineering problem the ICF and HEDP community are currently undertaking. Nondestructive characterization (NDC) provides a valuable tool in material selection, component inspection, and the final pre-shot assemblies inspection. X-rays are a key method used to NDC these targets. In this paper we discuss X-ray attenuation, X-ray phase effects, and the X-ray system used, its performance and application to characterize low-temperature Raleigh-Taylor and non-cryogenic double-shell targets.

  4. Radiography using a dense plasma focus device as a source of pulsed X-rays

    Science.gov (United States)

    Herrera, Julio; Castillo, Fermín; Gamboa, Isabel; Rangel, José

    2007-11-01

    Soft and hard X-ray emissions have been studied in the FN-II, which is a small dense plasma focus machine (5 kJ), operating at the Instituto de Ciencias Nucleares, UNAM, using aluminum filtered pin-hole cameras. Their angular distribution has been measured using TLD-200 dosimeters [1]. Their temporal evolution has been observed by means of a PIN diode, and scinltillators coupled to photomultipliers outside the discharge chamber. The X rays source can be concentrated by placing a needle on the end of the electrode. X-rays crossing across a 300 micron aluminum window, through the axis of the machine, can be used to obtain high contrast radiographs, with an average dose of 0.4 mGy per shot. In contrast, the average dose with a hollow cathode is 0.2 mGy per shot. This work is partially supported by grant IN105705 de la DGAPA-UNAM. [1] F. Castillo, J.J.E. Herrera, J. Rangel, I. Gamboa, G. Espinosa y J.I. Golzarri ``Angular Distribution of fusion products and X-rays emitted by a small dense plasma focus machine'' Journal of Applied Physics 101 013303-1-7 (2007).

  5. LONG-DURATION X-RAY FLASH AND X-RAY-RICH GAMMA-RAY BURSTS FROM LOW-MASS POPULATION III STARS

    Energy Technology Data Exchange (ETDEWEB)

    Nakauchi, Daisuke; Kashiyama, Kazumi; Nakamura, Takashi [Department of Physics, Kyoto University, Oiwake-cho, Kitashirakawa, Sakyo-ku, Kyoto 606-8502 (Japan); Suwa, Yudai [Yukawa Institute for Theoretical Physics, Kyoto University, Oiwake-cho, Kitashirakawa, Sakyo-ku, Kyoto 606-8502 (Japan); Sakamoto, Takanori [Center for Research and Exploration in Space Science and Technology (CRESST), NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States)

    2012-11-10

    Recent numerical simulations suggest that Population III (Pop III) stars were born with masses not larger than {approx}100 M {sub Sun} and typically {approx}40 M {sub Sun }. By self-consistently considering the jet generation and propagation in the envelope of these low-mass Pop III stars, we find that a Pop III blue supergiant star has the possibility of giving rise to a gamma-ray burst (GRB) even though it keeps a massive hydrogen envelope. We evaluate observational characteristics of Pop III GRBs and predict that Pop III GRBs have a duration of {approx}10{sup 5} s in the observer frame and a peak luminosity of {approx}5 Multiplication-Sign 10{sup 50} erg s{sup -1}. Assuming that the E {sub p}-L {sub p} (or E {sub p}-E {sub {gamma},iso}) correlation holds for Pop III GRBs, we find that the spectrum peak energy falls at approximately a few keV (or {approx}100 keV) in the observer frame. We discuss the detectability of Pop III GRBs by future satellite missions such as EXIST and Lobster. If the E {sub p}-E {sub {gamma},iso} correlation holds, we have the possibility to detect Pop III GRBs at z {approx} 9 as long-duration X-ray-rich GRBs by EXIST. Conversely, if the E {sub p}-L {sub p} correlation holds, we have the possibility to detect Pop III GRBs up to z {approx} 19 as long-duration X-ray flashes by Lobster.

  6. X-Ray Flashes in Recurrent Novae: M31N 2008-12a and the Implications of the Swift Non-detection

    CERN Document Server

    Kato, Mariko; Henze, Martin; Ness, Jan-Uwe; Osborne, Julian P; Page, Kim L; Darnley, Matthew J; Bode, Michael F; Shafter, Allen W; Hernanz, Margarita; Gehrels, Neil; Kennea, Jamie; Hachisu, Izumi

    2016-01-01

    Models of nova outbursts suggest that an X-ray flash should occur just after hydrogen ignition. However, this X-ray flash has never been observationally confirmed. We present four theoretical light curves of the X-ray flash for two very massive white dwarfs (WDs) of 1.380 and 1.385 M_sun and for two recurrence periods of 0.5 and 1 years. The duration of the X-ray flash is shorter for a more massive WD and for a longer recurrence period. The shortest duration of 14 hours (0.6 days) among the four cases is obtained for the 1.385 M_sun WD with one year recurrence period. In general, a nova explosion is relatively weak for a very short recurrence period, which results in a rather slow evolution toward the optical peak. This slow timescale and the predictability of very short recurrence period novae give us a chance to observe X-ray flashes of recurrent novae. In this context, we report the first attempt, using the Swift observatory, to detect an X-ray flash of the recurrent nova M31N 2008-12a (0.5 or 1 year recur...

  7. X-ray Flashes in Recurrent Novae: M31N 2008-12a and the Implications of the Swift Nondetection

    Science.gov (United States)

    Kato, Mariko; Saio, Hideyuki; Henze, Martin; Ness, Jan-Uwe; Osborne, Julian P.; Page, Kim L.; Darnley, Matthew J.; Bode, Michael F.; Shafter, Allen W.; Hernanz, Margarita; Gehrels, Neil; Kennea, Jamie; Hachisu, Izumi

    2016-10-01

    Models of nova outbursts suggest that an X-ray flash should occur just after hydrogen ignition. However, this X-ray flash has never been observationally confirmed. We present four theoretical light curves of the X-ray flash for two very massive white dwarfs (WDs) of 1.380 and 1.385 {M}⊙ and for two recurrence periods of 0.5 and 1 yr. The duration of the X-ray flash is shorter for a more massive WD and for a longer recurrence period. The shortest duration of 14 hr (0.6 days) among the four cases is obtained for the 1.385 {M}⊙ WD with a 1 yr recurrence period. In general, a nova explosion is relatively weak for a very short recurrence period, which results in a rather slow evolution toward the optical peak. This slow timescale and the predictability of very short recurrence period novae give us a chance to observe X-ray flashes of recurrent novae. In this context, we report the first attempt, using the Swift observatory, to detect an X-ray flash of the recurrent nova M31N 2008-12a (0.5 or 1 yr recurrence period), which resulted in the nondetection of X-ray emission during the period of 8 days before the optical detection. We discuss the impact of these observations on nova outburst theory. The X-ray flash is one of the last frontiers of nova studies, and its detection is essential for understanding the pre-optical-maximum phase. We encourage further observations.

  8. X-Ray Digital Radiography and Computed Tomography Characterization of Targets

    Energy Technology Data Exchange (ETDEWEB)

    Sain, J D; Brown, W D; Chinn, D J; Martz Jr., H E; Morales, K E; Schneberk, D J; Updike, E O

    2008-04-16

    The summary of this report is: (1) The Xradia Micro XCT and LLNL CCAT x-ray systems are used to nondestructively characterize a variety of materials, assemblies, and reference standard components; (2) The digital radiograph (DR) and computed tomography (CT) image data may be used for metrology, quality control, and defect detection; and (3) The ability to detect and characterize imperfections leads to improvements in the manufacturing processes for assemblies.

  9. Suresh K. AggarwalQuantified Analysis of a Production Diesel Injector Using X-Ray Radiography and Engine Diagnostics

    Science.gov (United States)

    Ramirez, Anita I.

    The work presented in this thesis pursues further the understanding of fuel spray, combustion, performance, and emissions in an internal combustion engine. Various experimental techniques including x-ray radiography, injection rate measurement, and in-cylinder endoscopy are employed in this work to characterize the effects of various upstream conditions such as injection rate profile and fuel physical properties. A single non-evaporating spray from a 6-hole full-production Hydraulically Actuated Electronically Controlled Unit Injector (HEUI) nozzle is studied under engine-like ambient densities with x-ray radiography at the Advanced Photon Source (APS) of Argonne National Laboratory (ANL). Two different injection pressures were investigated and parameters such as fuel mass distribution, spray penetration, cone angle, and spray velocity were obtained. The data acquired with x-ray radiography is used for the development and validation of improved Computational Fluid Dynamic (CFD) models. Rate of injection is studied using the same HEUI in a single cylinder Caterpillar test engine. The injection rate profile is altered to have three levels of initial injection pressure rise. Combustion behavior, engine performance, and emissions information was acquired for three rate profile variations. It is found that NOx emission reduction is achieved when the SOI timing is constant at the penalty of lower power generated in the cycle. However, if CA50 is aligned amongst the three profiles, the NOx emissions and power are constant with a slight penalty in CO emissions. The influence of physical and chemical parameters of fuel is examined in a study of the heavy alcohol, phytol (C20H40O), in internal combustion engine application. Phytol is blended with diesel in 5%, 10%, and 20% by volume. Combustion behavior is similar between pure diesel and the phytol/diesel blends with small differences noted in peak cylinder pressure, ignition delay, and heat release rate in the premix burn

  10. AIRIX: an induction accelerator facility developed at CEA for flash radiography in detonics

    Science.gov (United States)

    Cavailler, Claude

    1999-06-01

    AIRIX is an induction linear accelerator which will be used for flash radiography in CEA/DAM. Designed to produce an X-ray dose of more than 500 Rads at 1 meter with an X-ray focal spot size diameter of less than 2 mm (LANL-CEA DAM definition), this facility consists in a 4 MeV/3.5 kA pulsed electron injector and 16 MeV induction accelerator powered by 32 high voltage generators. A prototype of this accelerator, called PIVAIR, has been studied and realized in CEA CESTA near Bordeaux. PIVAIR is a validation step for AIRIX at 8 MeV. It includes an injector (4 MeV, 3.5 kA, 60 ns) and 16 inductor cells supplied by 8 high voltage generators (250 kV, 70 ns). Two different technologies of induction cells have been tested (rexolite insulator or ferrite under vacuum). We have chosen ferrite under vacuum cells technology after comparison of results on beam transport and reliability tests. A focusing experiment at 7.2 MeV of the electron beam as been achieved during summer 1997. We have begun to produce X-rays in October 1997. A dose level of 50 Rad at 1 meter has been achieved with an X-ray spot size diameter of 3.5 to 4 mm (LANL-CEA DAM definition). Static flash radiography of very dense object have been achieved from November 97 until February 98. We have been able to test in situ new kinds of very high sensitive X- ray detectors and to check they had reached our very ambitious goals: (1) quantum efficiency at 5 MeV greater than 50% instead of 1% for luminous screens and film; (2) sensitivity less than 10 (mu) Rad (100 time more sensitive than radiographic luminous screens and films); (3) dynamic range greater than 100; (4) resolution less than 2 mm. We will present in this communication brand new kinds of detection systems, called high stopping power detectors, such as: (1) (gamma) camera with segmented thick crystal of BGO and MCP image intensifier; (2) multistep parallel plate avalanche chamber; (3) pixellized CdTe MeV photoconductor matrix. AIRIX accelerator is being

  11. An accelerator scenario for hard X-ray free electron laser joint with high energy electron radiography

    CERN Document Server

    Wei, Tao; Yang, Guojun; Pang, Jian; Li, Yuhui; Li, Peng; Pflueger, Joachim; He, Xiaozhong; Lu, Yaxing; Wang, Ke; Long, Jidong; Zhang, Linwen; Wu, Qiang

    2016-01-01

    In order to study the dynamic response of the material and the physical mechanism of the fluid dynamics, an accelerator scenario which can be applied to hard X-ray free electron laser and high energy electron radiography was proposed. This accelerator is mainly composed of a 12GeV linac, an undulator branch and an eRad beamline. In order to characterize sample's dynamic behavior in situ and real-time with XFEL and eRad simultaneously, the linac should be capable of accelerating the two kinds of beam within the same operation mode. Combining with in-vacuum and tapering techniques, the undulator branch can produce more than 1E11 photons per pulse in 0.1 precent bandwidth at 42keV. Finally, the eRad amplifying beamline with 1:10 ratio was proposed as an important complementary tool for the wider view field and density identification ability.

  12. Experience of the Indirect Neutron Radiography Method Based on the X-ray Imaging Plate at CARR

    Science.gov (United States)

    Wei, Guohai; Han, Songbai; Wang, Hongli; He, Linfeng; Wang, Yu; Wu, Meimei; Liu, Yuntao; Chen, Dongfeng

    Indirect neutron radiography (INR) experiments by X-ray imaging plate were carried out at the China Advanced Research Reactor (CARR). The key experiment parameters were optimized, especially the exposure time of the neutron converter andimaging plate. The optimized total exposure time is 37.25 min, it is two-fifths of the timebased on the film method under the same experimental conditions. The qualitative and quantitativeinspections were tested with dummy nuclear fuel rods and a water temperaturesensor ofa motor vehicle. The spring in the sensor and the defects of the dummy fuel rod's pellets can be qualitatively detected. The thickness of the tape at one position on the cladding of the dummy nuclear fuel rodwas quantitatively calculated to be 9.57 layers with the relative error of ±4.3%.

  13. Generation and characterization of plasma channels in gas puff targets using soft X-ray radiography technique

    Energy Technology Data Exchange (ETDEWEB)

    Wachulak, P. W., E-mail: wachulak@gmail.com; Bartnik, A.; Jarocki, R.; Fok, T.; Węgrzyński, Ł.; Kostecki, J.; Szczurek, M.; Jabczyński, J.; Fiedorowicz, H. [Institute of Optoelectronics, Military University of Technology, ul. gen. S. Kaliskiego 2, 00-908 Warsaw (Poland)

    2014-10-15

    We present our recent results of a formation and characterization of plasma channels in elongated krypton and xenon gas puff targets. The study of their formation and temporal expansion was carried out using a combination of a soft X-ray radiography (shadowgraphy) and pinhole camera imaging. Two high-energy short laser pulses were used to produce the channels. When a pumping laser pulse was shaped into a line focus, using cylindrical and spherical lenses, the channels were not produced because much smaller energy density was deposited in the gas puff target. However, when a point focus was obtained, using just a spherical lens, the plasma channels appeared. The channels were up to 9 mm in length, had a quite uniform density profile, and expanded in time with velocities of about 2 cm/μs.

  14. Characterisation of Late Bronze Age large size shield nails by EDXRF, micro-EDXRF and X-ray digital radiography.

    Science.gov (United States)

    Figueiredo, E; Araújo, M F; Silva, R J C; Senna-Martinez, J C; Vaz, J L Inês

    2011-09-01

    In the present study six exceptional large size metallic nails, a dagger and a sickle from the Late Bronze Age archaeological site of Figueiredo das Donas (Central Portugal) have been analysed by EDXRF, micro-EDXRF and X-ray digital radiography for the study of material composition and technology of fabrication. The combination of these analytical and examination techniques showed that all artefacts are made of bronze with As, Sb and Pb impurities, and that the nails were most likely manufactured using the casting-on technique. These results reinforce the use of binary bronze by Late Bronze Age in the region, and the incorporation of new fabrication technologies that resulted from ancient spheres of interaction.

  15. Contrast optimization in X-ray radiography with single photon counting imagers of Medipix type

    Science.gov (United States)

    Jandejsek, I.; Dammer, J.; Jakubek, J.; Vavrik, D.; Zemlicka, J.

    2012-12-01

    Systematical measurement and optimization of the image contrast in the terms of the signal to noise ratio (SNR) reached by two detector systems Medipix2 (Si sensor) and Flat Panel (Scintillator + CMOS) is the aim of this work. The measurement is carried out with micro-focus X-ray source and aluminum step phantom specimen of various thicknesses. The SNR is computed from measured image data for various combination of aluminum thicknesses and in dependence on tube voltage and acquisition time. On the basis of the results, the comparison of two detector systems is done and the illustrative SNR optimization process for a hypothetical and real samples is demonstrated.

  16. Quality control tool of electrode coating for lithium-ion batteries based on X-ray radiography

    Science.gov (United States)

    Etiemble, A.; Besnard, N.; Adrien, J.; Tran-Van, P.; Gautier, L.; Lestriez, B.; Maire, E.

    2015-12-01

    A simple and efficient method, based on X-ray radiography, is developed to check the quality (homogeneity of the thickness, presence of defects) of NMC-, LFP- and NMC/LFP-based electrode coating for Li-ion batteries at the scale of several cm2 with a resolution of 20 μm. As a first step, the attenuation coefficient of NMC- and LFP-based coating is experimentally determined according to the Beer-Lambert law. Then, the attenuation coefficient of each active material is estimated from these experimental results and X-ray attenuation databases, which allows establishing an attenuation law for any coating composition. Finally, thanks to this relationship, the thickness can be evaluated in each spot of the film and the defects, such as pinholes or broad edges with gradual decrease of the thickness coating, can be detected. The analysis of NMC-, LFP- and NMC/LFP-based electrodes shows that the coating quality decreases as coating thickness increases and as the nanometric vs. micrometric material content increases in the coating composition. This reveals detrimental aspects of nanomaterials with respect to their use in composite electrode manufactured through conventional slot-die or casting process.

  17. In situ rheological measurements at extreme pressure and temperature using synchrotron X-ray diffraction and radiography.

    Science.gov (United States)

    Raterron, Paul; Merkel, Sébastien

    2009-11-01

    Dramatic technical progress seen over the past decade now allows the plastic properties of materials to be investigated under extreme pressure and temperature conditions. Coupling of high-pressure apparatuses with synchrotron radiation significantly improves the quantification of differential stress and specimen textures from X-ray diffraction data, as well as specimen strains and strain rates by radiography. This contribution briefly reviews the recent developments in the field and describes state-of-the-art extreme-pressure deformation devices and analytical techniques available today. The focus here is on apparatuses promoting deformation at pressures largely in excess of 3 GPa, namely the diamond anvil cell, the deformation-DIA apparatus and the rotational Drickamer apparatus, as well as on the methods used to carry out controlled deformation experiments while quantifying X-ray data in terms of materials rheological parameters. It is shown that these new techniques open the new field of in situ investigation of materials rheology at extreme conditions, which already finds multiple fundamental applications in the understanding of the dynamics of Earth-like planet interior.

  18. Sensitivity study of proton radiography and comparison with kV and MV x-ray imaging using GEANT4 Monte Carlo simulations.

    Science.gov (United States)

    Depauw, Nicolas; Seco, Joao

    2011-04-21

    The imaging sensitivity of proton radiography has been studied and compared with kV and MV x-ray imaging using Monte Carlo simulations. A phantom was specifically modeled using 21 different material inserts with densities ranging from 0.001 to 1.92 g cm(-3). These simulations were run using the MGH double scattered proton beam, scanned pencil proton beams from 200 to 490 MeV, as well as pure 50 keV, 100 keV, 1 MeV and 2 MeV gamma x-ray beams. In order to compare the physics implied in both proton and photon radiography without being biased by the current state of the art in detector technology, the detectors were considered perfect. Along with spatial resolution, the contrast-to-noise ratio was evaluated and compared for each material. These analyses were performed using radiographic images that took into account the following: only primary protons, both primary and secondary protons, and both contributions while performing angular and energetic cuts. Additionally, tissue-to-tissue contrasts in an actual lung cancer patient case were studied for simulated proton radiographs and compared against the original kV x-ray image which corresponds to the current patient set-up image in the proton clinic. This study highlights the poorer spatial resolution of protons versus x-rays for radiographic imaging purposes, and the excellent density resolution of proton radiography. Contrasts around the tumor are higher using protons in a lung cancer patient case. The high-density resolution of proton radiography is of great importance for specific tumor diagnostics, such as in lung cancer, where x-ray radiography operates poorly. Furthermore, the use of daily proton radiography prior to proton therapy would ameliorate patient set-up while reducing the absorbed dose delivered through imaging.

  19. High-energy x-ray Talbot-Lau radiography of a human knee

    Science.gov (United States)

    Horn, F.; Gelse, K.; Jabari, S.; Hauke, C.; Kaeppler, S.; Ludwig, V.; Meyer, P.; Michel, T.; Mohr, J.; Pelzer, G.; Rieger, J.; Riess, C.; Seifert, M.; Anton, G.

    2017-08-01

    We report on a radiographic measurement of an ex vivo human knee using a grating-based phase-contrast imaging setup and a medical x-ray tube at a tube voltage of 70 kV. The measurement has been carried out using a Talbot-Lau setup that is suitable to achieve a high visibility in the energy regime of medical imaging. In a medical reading by an experienced trauma surgeon signatures of chondrocalcinosis in the medial meniscus have been identified more evidently using the dark-field image in comparison to the conventional attenuation image. The analysis has been carried out at various dose levels down to 0.14 mGy measured as air kerma, which is a dose comparable to clinically used radiographic devices. The diagnosis has been confirmed by a histological analysis of the meniscus tissue. In the introduced high-frequency filtered phase-contrast image the anterior and posterior horn of the medial meniscus and the posterior cruciate ligament have also been visible. Furthermore, atherosclerotic plaque is visible in both imaging modalities, attenuation and dark-field, despite the presence of overlaying bone. This measurement, for the first time, proves the feasibility of Talbot-Lau x-ray imaging at high-energy spectra above 40 kVp and reasonable dose levels with regard to spacious and dense objects.

  20. Near-isothermal furnace for in situ and real time X-ray radiography solidification experiments

    Energy Technology Data Exchange (ETDEWEB)

    Becker, M., E-mail: maike.becker@dlr.de; Dreißigacker, C.; Klein, S.; Kargl, F. [Institut für Materialphysik im Weltraum, Deutsches Zentrum für Luft- und Raumfahrt (DLR), 51170 Köln (Germany)

    2015-06-15

    In this paper, we present a newly developed near-isothermal X-ray transparent furnace for in situ imaging of solidification processes in thin metallic samples. We show that the furnace is ideally suited to study equiaxed microstructure evolution and grain interaction. To observe the growth dynamics of equiaxed dendritic structures, a minimal temperature gradient across the sample is required. A uniform thermal profile inside a circular sample is achieved by positioning the sample in the center of a cylindrical furnace body surrounded by a circular heater arrangement. Performance tests with the hypo-eutectic Al-15wt.%Cu and the near-eutectic Al-33wt.%Cu alloys validate the near-isothermal character of the sample environment. Controlled cooling rates of less than 0.5 K min{sup −1} up to 10 K min{sup −1} can be achieved in a temperature range of 720 K–1220 K. Integrated in our rotatable laboratory X-ray facility, X-RISE, the furnace provides a large field of view of 10.5 mm in diameter and a high spatial resolution of ∼4 μm. With the here presented furnace, equiaxed dendrite growth models can be rigorously tested against experiments on metal alloys by, e.g., enabling dendrite growth velocities to be determined as a function of undercooling or solutal fields in front of the growing dendrite to be measured.

  1. High energy x-ray radiography and computed tomography of bridge pins

    Energy Technology Data Exchange (ETDEWEB)

    Green, R E; Logan, C M; Martz, H E; Updike, E; Waters, A M

    1999-05-01

    Bridge pins were used in the hanger assemblies for some multi-span steel bridges built prior to the 1980's, and are sometimes considered fracture critical elements of a bridge. During a test on a bridge conducted by the Federal Highway Administration (FHWA), ultrasonic field inspection results indicated that at least two pins contained cracks. Several pins were removed and selected for further examination. This provided an excellent opportunity to learn more about these pins and the application of x-ray systems at Lawrence Livermore National Laboratory (LLNL), as well as to learn more about the application of different detectors recently obtained by LLNL. Digital radiographs and computed tomography (CT) were used to characterize the bridge pins, using a LINAC x-ray source with a 9-MV bremsstrahlung spectrum. We will describe the performance of two different digital radiographic detectors. One is a detector system frequently used at LLNL consisting of a scintillator glass optically coupled to a CCD camera. The other detector is a new amorphous silicon detector recently acquired by LLNL.

  2. Nonthermal gamma-ray and X-ray flashes from shock breakout in gamma-ray bursts/supernovae

    CERN Document Server

    Wang, X Y; Waxman, E; Mészáros, P; Wang, Xiang-Yu; Li, Zhuo; Waxman, Eli; Meszaros, Peter

    2006-01-01

    Thermal X-ray emission which is simultaneous with the prompt gamma-rays has been detected for the first time from a supernova connected with a gamma-ray burst (GRB), namely GRB060218/SN2006aj. It has been interpreted as arising from the breakout of a mildly relativistic, radiation-dominated shock from a dense stellar wind surrounding the progenitor star. There is also evidence for the presence of a mildly relativistic ejecta in GRB980425/SN1998bw, based on its X-ray and radio afterglow. Here we study the process of repeated bulk Compton scatterings of shock breakout thermal photons by the mildly relativistic ejecta. During the shock breakout process, a fraction of the thermal photons would be repeatedly scattered between the pre-shock material and the shocked material as well as the mildly relativistic ejecta and, as a result, the thermal photons get boosted to increasingly higher energies. This bulk motion Comptonization mechanism will produce nonthermal gamma-ray and X-ray flashes, which could account for t...

  3. Quantitative studies on inner interfaces in conical metal joints using hard x-ray inline phase contrast radiography

    Energy Technology Data Exchange (ETDEWEB)

    Zabler, S. [Institute for Materials Science, Technical University of Berlin, EB 13, Strasse des 17, Juni 135, D-10623 Berlin (Germany); Rack, T.; Nelson, K. [Clinic for Oral and Maxifacial Surgery, Charite University Medicine, Augustenburger Platz 1, D-13353 Berlin (Germany); Rack, A. [European Synchrotron Radiation Facility, 6 rue Jules Horowitz, BP 220, F-38043 Grenoble (France)

    2010-10-15

    Quantitative investigation of micrometer and submicrometer gaps between joining metal surfaces is applied to conical plug-socket connections in dental titanium implants. Microgaps of widths well beyond the resolving power of industrial x-ray systems are imaged by synchrotron phase contrast radiography. Furthermore, by using an analytical model for the relatively simple sample geometry and applying it to numerical forward simulations of the optical Fresnel propagation, we show that quantitative measurements of the microgap width down to 0.1 {mu}m are possible. Image data recorded at the BAMline (BESSY-II light source, Germany) are presented, with the resolving power of the imaging system being 4 {mu}m in absorption mode and {approx}14 {mu}m in phase contrast mode (z{sub 2}=0.74 m). Thus, phase contrast radiography, combined with numerical forward simulations, is capable of measuring the widths of gaps that are two orders of magnitude thinner than the conventional detection limit.

  4. Shape-from-silhouette for three-dimensional reconstruction from x-ray radiography

    Science.gov (United States)

    Simioni, E.; Ratti, F.; Poletto, L.

    2011-06-01

    We present the application of the shape-from-silhouette algorithm to reconstruct the 3D profile of handworks from a set of X-ray absorption images taken at different angles around the object. The acquisition technique is similar to tomography, but the number of images that are required to reconstruct the 3D appearance is very low compared to tomography, therefore the acquisition time is substantially reduced. Some reference points are placed on a structure corotating with the object and are acquired on the images for calibration and registration. The shape-from-silhouette algorithm gives finally the 3D appearance of the object. We present the analysis of a tin pendant from the Venetic area, VI century b.C., that was completely hidden by corrosion products and solid ground at the moment of the retrieval. The 3D reconstruction shows that the pendant is a very elaborated piece, with two embraced figures that were completely invisible before restoration.

  5. Scattering Correction For Image Reconstruction In Flash Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Cao, Liangzhi; Wang, Mengqi; Wu, Hongchun; Liu, Zhouyu; Cheng, Yuxiong; Zhang, Hongbo [Xi' an Jiaotong Univ., Xi' an (China)

    2013-08-15

    Scattered photons cause blurring and distortions in flash radiography, reducing the accuracy of image reconstruction significantly. The effect of the scattered photons is taken into account and an iterative deduction of the scattered photons is proposed to amend the scattering effect for image restoration. In order to deduct the scattering contribution, the flux of scattered photons is estimated as the sum of two components. The single scattered component is calculated accurately together with the uncollided flux along the characteristic ray, while the multiple scattered component is evaluated using correction coefficients pre-obtained from Monte Carlo simulations.The arbitrary geometry pretreatment and ray tracing are carried out based on the customization of AutoCAD. With the above model, an Iterative Procedure for image restORation code, IPOR, is developed. Numerical results demonstrate that the IPOR code is much more accurate than the direct reconstruction solution without scattering correction and it has a very high computational efficiency.

  6. Evaluation of X-Ray Protective Measurements in Intraoral Radiography Equipped Centers in Yazd

    Directory of Open Access Journals (Sweden)

    D.Goodarzi Pour

    2005-02-01

    Full Text Available Statement of Problem: A few decades have past from using radiographic technology as an accurate paraclinical method and always protective measurements is applicated against ionizing radiation. As dentalradiography is a routine procedure in dentistry the importance of protective strategies is clear.Propose: The aim of this descriptive study is to evaluate the protection principles in centers which haveintraoral radiographic devices in Yazd.Material and Methods: We have considered all three aspects of practitioner, environment and patientprotection using questionnaire and visiting those centers.Results: 33/7% of dental offices ,10 clinics ,3 institution and faculty of dentistry had intraoral radiographicequipments. Stablishment of protection principles for radiographer was favorable. 7.7% of centers had x-ray room with leaded walls, 23.1% had curtain , in 69/2% of centers radiographers stood in correct position anddistance while taking radiograph. Regarding to protection of environment, beams leakage control in 23.1% dental offices, 70% of clinics, all institution and faculty of dentistry have done.Conclusion: Non of the centers used rectangular localizator, thyroid shield, film holder and just some centers used leaded apron in specific circumstances. We have concluded that patient protection constitute less consideration. Generally lack of protective consideration is related to deficient knowledge of operators. Lackof information about protection equipments causes decrease of demanding of these tools and ultimately lack of these equipments in the market.

  7. Pre-treatment patient-specific stopping power by combining list-mode proton radiography and x-ray CT

    Science.gov (United States)

    Collins-Fekete, Charles-Antoine; Brousmiche, Sébastien; Hansen, David C.; Beaulieu, Luc; Seco, Joao

    2017-09-01

    The relative stopping power (RSP) uncertainty is the largest contributor to the range uncertainty in proton therapy. The purpose of this work was to develop a systematic method that yields accurate and patient-specific RSPs by combining (1) pre-treatment x-ray CT and (2) daily proton radiography of the patient. The method was formulated as a penalized least squares optimization problem (argmin(\\Vert {A}{x}-{b}\\Vert _22 )). The parameter A represents the cumulative path-length crossed by the proton in each material, separated by thresholding on the HU. The material RSPs (water equivalent thickness/physical thickness) are denoted by x. The parameter b is the list-mode proton radiography produced using Geant4 simulations. The problem was solved using a non-negative linear-solver with {x}≥slant0 . A was computed by superposing proton trajectories calculated with a cubic or linear spline approach to the CT. The material’s RSP assigned in Geant4 were used for reference while the clinical HU-RSP calibration curve was used for comparison. The Gammex RMI-467 phantom was first investigated. The standard deviation between the estimated material RSP and the calculated RSP is 0.45%. The robustness of the techniques was then assessed as a function of the number of projections and initial proton energy. Optimization with two initial projections yields precise RSP (⩽1.0%) for 330 MeV protons. 250 MeV protons have shown higher uncertainty (⩽2.0%) due to the loss of precision in the path estimate. Anthropomorphic phantoms of the head, pelvis, and lung were subsequently evaluated. Accurate RSP has been obtained for the head (μ =0.21+/-1.63% ), the lung (μ=0.06+/-0.99% ) and the pelvis (μ=0.90+/-3.87% ). The range precision has been optimized using the calibration curves obtained with the algorithm, yielding a mean R80 difference to the reference of 0.11  ±0.09%, 0.28  ±  0.34% and 0.05 +/- 0.06% in the same order. The solution’s accuracy is limited by the

  8. Reproducibility of Standing Posture for X-Ray Radiography: A Feasibility Study of the BalancAid with Healthy Young Subjects

    Science.gov (United States)

    Dewi, Dyah Ekashanti Octorina; Veldhuizen, Albert G.; Burgerhof, Johannes G. M.; Purnama, I Ketut Eddy; van Ooijen, Peter M. A.; Wilkinson, Michael H. F.; Mengko, Tati Latifah Erawati Rajab

    2010-01-01

    Unreliable spinal X-ray radiography measurement due to standing postural variability can be minimized by using positional supports. In this study, we introduce a balancing device, named BalancAid, to position the patients in a reproducible position during spinal X-ray radiography. This study aimed to investigate the performance of healthy young subjects’ standing posture on the BalancAid compared to standing on the ground mimicking the standard X-rays posture in producing a reproducible posture for the spinal X-ray radiography. A study on the posture reproducibility measurement was performed by taking photographs of 20 healthy young subjects with good balance control standing on the BalancAid and the ground repeatedly within two consecutive days. We analyzed nine posterior–anterior (PA) and three lateral (LA) angles between lines through body marks placed in the positions of T3, T7, T12, L4 of the spine to confirm any translocations and movements between the first and second day measurements. No body marks repositioning was performed to avoid any error. Lin’s CCC test on all angles comparing both standing postures demonstrated that seven out of nine angles in PA view, and two out of three angles in LA view gave better reproducibility for standing on the BalancAid compared to standing on the ground. The PA angles concordance is on average better than that of the LA angles. PMID:20473569

  9. Dosimetric study of the effective doses resulting during dental X-ray and panoramic radiography

    Science.gov (United States)

    Shousha, Hany A.; Abd-El Hafez, A. I.; Ahmad, Fawzia

    2011-01-01

    The panoramic image is one of the most commonly used radiographic examinations in dentistry, owing to its low dose and large area for evaluation, including bone and teeth in the same image. Although digital images are usually reported to deliver a lower radiation dose to the patient, conventional images are still available, especially in countries where digital systems are not widely economically available. Dentists should weigh the benefits of dental radiographs against the consequences of increasing a patient's exposure to radiation, the effects of which accumulate from multiple sources over time. The "as low as reasonably achievable" principle should be followed to minimize the exposure to radiation. The purpose of this investigation is to measure the absorbed radiation doses at 12 anatomical sites of a Rando-phantom and calculate the effective doses result from a full-mouth survey and panoramic radiography. Organ-absorbed doses are measured using thermoluminescent dosimeters (TLD 100) and effective organ doses (μ Sv) are estimated according to the International Commission on Radiological Protection in 2007. The total effective dose results from the panoramic imaging system have so far been below those obtained using the full-mouth survey technique used in intra-oral radiographic examination.

  10. A data set from flash X-ray imaging of carboxysomes

    Science.gov (United States)

    Hantke, Max F.; Hasse, Dirk; Ekeberg, Tomas; John, Katja; Svenda, Martin; Loh, Duane; Martin, Andrew V.; Timneanu, Nicusor; Larsson, Daniel S. D.; van der Schot, Gijs; Carlsson, Gunilla H.; Ingelman, Margareta; Andreasson, Jakob; Westphal, Daniel; Iwan, Bianca; Uetrecht, Charlotte; Bielecki, Johan; Liang, Mengning; Stellato, Francesco; Deponte, Daniel P.; Bari, Sadia; Hartmann, Robert; Kimmel, Nils; Kirian, Richard A.; Seibert, M. Marvin; Mühlig, Kerstin; Schorb, Sebastian; Ferguson, Ken; Bostedt, Christoph; Carron, Sebastian; Bozek, John D.; Rolles, Daniel; Rudenko, Artem; Foucar, Lutz; Epp, Sascha W.; Chapman, Henry N.; Barty, Anton; Andersson, Inger; Hajdu, Janos; Maia, Filipe R. N. C.

    2016-08-01

    Ultra-intense femtosecond X-ray pulses from X-ray lasers permit structural studies on single particles and biomolecules without crystals. We present a large data set on inherently heterogeneous, polyhedral carboxysome particles. Carboxysomes are cell organelles that vary in size and facilitate up to 40% of Earth’s carbon fixation by cyanobacteria and certain proteobacteria. Variation in size hinders crystallization. Carboxysomes appear icosahedral in the electron microscope. A protein shell encapsulates a large number of Rubisco molecules in paracrystalline arrays inside the organelle. We used carboxysomes with a mean diameter of 115±26 nm from Halothiobacillus neapolitanus. A new aerosol sample-injector allowed us to record 70,000 low-noise diffraction patterns in 12 min. Every diffraction pattern is a unique structure measurement and high-throughput imaging allows sampling the space of structural variability. The different structures can be separated and phased directly from the diffraction data and open a way for accurate, high-throughput studies on structures and structural heterogeneity in biology and elsewhere.

  11. High resolution synchrotron-based radiography and tomography using hard X-rays at the BAM line (BESSY II)

    Science.gov (United States)

    Rack, A.; Zabler, S.; Müller, B. R.; Riesemeier, H.; Weidemann, G.; Lange, A.; Goebbels, J.; Hentschel, M.; Görner, W.

    2008-02-01

    The use of high brilliance and partial coherent synchrotron light for radiography and computed tomography (CT) allows to image micro-structured, multi-component specimens with different contrast modes and resolutions up to submicrometer range. This is of high interest for materials research, life science and non-destructive evaluation applications. An imaging setup for microtomography and radiography installed at BESSY II (a third generation synchrotron light source located in Berlin, Germany) as part of its first hard X-ray beamline (BAM line) can now be used for absorption, refraction as well as phase contrast — dedicated to inhouse research and applications by external users. Monochromatic synchrotron light between 6 keV and 80 keV is attained via a fully automated double multilayer monochromator. For imaging applications the synchrotron beam transmitted by the sample is converted with a scintillator into visible light. By use of microscope optics this luminescence image is then projected onto, e.g., a CCD chip. Several scintillating materials are used in order to optimise the performance of the detector system. Different optical systems are available for imaging ranging from a larger field of view and moderate resolutions (macroscope — up to 14 mm×14 mm field of view) to high resolution (microscope — down to 0.35 μm pixel size), offering magnifications from 1.8× to 40×. Additionally asymmetric cut Bragg crystals in front of the scintillator can be used for a further magnification in one dimension by a factor of about 20. Slow and fast cameras are available, with up to 16 bit dynamic range. We show the suitability of the setup for numerous applications from materials research and life science.

  12. Search for Soft X-ray Flashes at Fireball Phase of Classical/Recurrent Novae using MAXI/GSC data

    CERN Document Server

    Morii, Mikio; Mihara, Tatehiro; Matsuoka, Masaru; Kawai, Nobuyuki

    2016-01-01

    We searched for precursive soft X-ray flashes (SXFs) associated with optically-discovered classical or recurrent novae in the data of five-years all-sky observations with Gas Slit Camera (GSC) of the Monitor of All-sky X-ray Image (MAXI). We first developed a tool to measure fluxes of point sources by fitting the event distribution with the model that incorporates the point-spread function (PSF-fit) to minimize the potential contamination from nearby sources. Then we applied the PSF-fit tool to 40 classical/recurrent novae that were discovered in optical observations from 2009 August to 2014 August. We found no precursive SXFs with significance above $3 \\sigma$ level in the energy range of 2$-$4 keV between $t_{d}-10$d and $t_{d}$, where $t_{d}$ is the date when each nova was discovered. We obtained the upper limits for the bolometric luminosity of SXFs, and compared them with the theoretical prediction and that observed for MAXI J0158$-$744. This result could constrain the population of massive white dwarfs ...

  13. Assessing the dose values received by patients during conventional radiography X-ray examinations and the technical condition of the equipment used for this purpose

    Directory of Open Access Journals (Sweden)

    Marcin Bekas

    2014-12-01

    Full Text Available Background: X-ray examination is associated with patient exposure to ionizing radiation. Dose values depend on the type of medical procedure used, the X-ray unit technical condition and exposure conditions selected. The aim of this study was to determine the dose value received by patients during certain conventional radiography X-ray examinations and to assess the technical condition of medical equipment used for this purpose. Material and Methods: The study covered the total number of 118 conventional diagnostic X-ray units located in the Masovian Voivodeship. The methodology used to assess the conventional diagnostic X-ray unit technical condition and the measurement of the radiation dose rate received by patients are based on test procedures developed by the Department of Radiation Protection and Radiobiology of the National Institute of Public Health – National Institute of Hygiene (Warszawa, Poland accredited for compliance with PN-EN 17025 standard by the Polish Centre for Accreditation. Results: It was found that 84.7% of X-ray units fully meet the criteria set out in the Polish legislation regarding the safe use of ionizing radiation in medicine, while 15.3% of the units do not meet some of them. The broadest dose value range was recorded for adult patients. Particularly, during lateral (LAT lumbar spine radiography the recorded entrance surface dose (ESD values ranged from 283.5 to 7827 μGy (mean: 2183.3 μGy. Conclusions: It is absolutely necessary to constantly monitor the technical condition of all X-ray units, because it affects population exposure to ionizing radiation. Furthermore, it is essential to raise radiographers’ awareness of the effects that ionizing radiation exposure can have on the human body. Med Pr 2014;65(6:715–721

  14. Survey of the Use of X-ray Beam Collimator and Shielding Tools during Infant Chest Radiography

    Directory of Open Access Journals (Sweden)

    Vahid Karami

    2016-04-01

    Full Text Available Background The use of shielding tools and X-ray beam collimator has extensively been advocated as effective methods to reduce radiation exposure to patients underwent radiological procedures. The aim of this study was to address the use of these protection measures during infant chest radiography. Material and Methods 348digital and/or analogue infant chest radiographs were reviewed that performed between October-  and December 2015 at four main hospitals of Khuzestan-Iran province to assessment the beam collimation. For each radiograph the area between current and acceptable collimation was calculated. Thirty eight radiographers were deeply interviewed to investigate the actual use of shielding tools and the main reasons for not using of them. Results Only 54 (15.5% radiographs [33(61% analogues and 21(39% digital] have satisfactory collimation. The total means area of diagnostic interest (ADI and the region outside ADI for each radiograph was estimated 171 and 86 cm2, respectively. The irradiated region outside the ADI was significantly larger in digital than in analogue images (mean of 103 cm2 vs. 54 cm2; P < 0.05. Shielding tools were used regularly only by 5% of radiographers. Conclusion The radiosensitive organs of infants located outside of ADI in hospitals investigated are at risk. Adherence to safety guideline urgently recommends.

  15. Contrast-Enhanced Proton Radiography for Patient Set-up by Using X-Ray CT Prior Knowledge

    Energy Technology Data Exchange (ETDEWEB)

    Spadea, Maria Francesca, E-mail: mfspadea@unicz.it [Department of Experimental and Clinical Medicine, Magna Graecia University, Catanzaro (Italy); Fassi, Aurora [Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milano (Italy); Zaffino, Paolo [Department of Experimental and Clinical Medicine, Magna Graecia University, Catanzaro (Italy); Riboldi, Marco; Baroni, Guido [Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milano (Italy); Bioengineering Unit—CNAO Foundation, Pavia (Italy); Depauw, Nicolas [Department of Radiation Oncology, Harvard Medical School and Massachusetts General Hospital, Boston, Massachusetts (United States); Centre for Medical Radiation Physics, University of Wollongong, Wollongong (Australia); Seco, Joao [Department of Radiation Oncology, Harvard Medical School and Massachusetts General Hospital, Boston, Massachusetts (United States)

    2014-11-01

    Purpose: To obtain a contrasted image of the tumor region during the setup for proton therapy in lung patients, by using proton radiography and x-ray computed tomography (CT) prior knowledge. Methods and Materials: Six lung cancer patients' CT scans were preprocessed by masking out the gross tumor volume (GTV), and digitally reconstructed radiographs along the planned beam's eye view (BEV) were generated, for a total of 27 projections. Proton radiographies (PR) were also computed for the same BEV through Monte Carlo simulations. The digitally reconstructed radiograph was subtracted from the corresponding proton image, resulting in a contrast-enhanced proton radiography (CEPR). Michelson contrast analysis was performed both on PR and CEPR. The tumor region was then automatically segmented on CEPR and compared to the ground truth (GT) provided by physicians in terms of Dice coefficient, accuracy, precision, sensitivity, and specificity. Results: Contrast on CEPR was, on average, 4 times better than on PR. For 10 lateral projections (±45° off of 90° or 270°), although it was not possible to distinguish the tumor region in the PR, CEPR offers excellent GTV visibility. The median ± quartile values of Dice, precision, and accuracy indexes were 0.86 ± 0.03, 0.86 ± 0.06, and 0.88 ± 0.02, respectively, thus confirming the reliability of the method in highlighting tumor boundaries. Sensitivity and specificity analysis demonstrated that there is no systematic over- or underestimation of the tumor region. Identification of the tumor boundaries using CEPR resulted in a more accurate and precise definition of GTV compared to that obtained from pretreatment CT. Conclusions: In most proton centers, the current clinical protocol is to align the patient using kV imaging with bony anatomy as a reference. We demonstrated that CEPR can significantly improve tumor visualization, allowing better patient set-up and permitting image guided proton therapy (IGPT)

  16. Study and optimization of negative polarity rod pinch diode as flash radiography source at 4.5 MV

    Science.gov (United States)

    Etchessahar, Bertrand; Bernigaud, Virgile; Caron, Michel; Cartier, Frédéric; Cartier, Stéphanie; Hourdin, Laurent; Magnin, Laurent; Nicolas, Rémi; Poulet, Frédéric; Rosol, Rodolphe; Tailleur, Yaël; Toury, Martial; Compant La Fontaine, Antoine; Bicrel, Béatrice; Cassany, Bruno; Desanlis, Thierry; Voisin, Luc; Hébert, David; Delbos, Christophe; Garrigues, Alain; Soleilhavoup, Isabelle

    2012-09-01

    The negative polarity rod pinch diode (NPRPD) is a potential millimeter spot size radiography source for high voltage generators (4 to 8 MV) [Cooperstein et al., "Considerations of rod-pinch diode operation in negative polarity for radiography," in Proceedings of the 14th IEEE Pulsed Power Conference, 2003, pp. 975-978]. The NPRPD consists of a small diameter (few mm) cylindrical anode extending from the front end of the vacuum cell through a thin annular cathode, held by a central conductor. The polarity has been inverted when compared to the original rod pinch diode [Cooperstein et al., "Theoretical modeling and experimental characterization of a rod-pinch diode," Phys. Plasmas 8(10), 4618-4636 (2001)] in order to take advantage from the maximal x-ray emission toward the anode holder at such a voltage [Swanekamp et al., "Evaluation of self-magnetically pinched diodes up to 10 MV as high resolution flash X-ray sources," IEEE Trans. Plasma Sci. 32(5), 2004-2016 (2004). We have studied this diode at 4.5 MV, driven by the ASTERIX generator [Raboisson et al., "ASTERIX, a high intensity X-ray generator," in Proceedings of the 7th IEEE Pulsed Power Conference, 1989, pp. 567-570.]. This generator, made up of a capacitor bank and a Blumlein line, was initially designed to test the behavior of electronic devices under irradiation. In our experiments, the vacuum diode has been modified in order to set up flash a radiographic diode [Etchessahar et al., "Negative polarity rod pinch diode experiments on the ASTERIX generator," in Conference Records-Abstracts, 37th IEEE International Conference on Plasma Science, 2010]. The experiments and numerical simulations presented here allowed the observation and analysis of various physical phenomena associated with the diode operation. Also, the influence of several experimental parameters, such as cathode and anode diameters, materials and surface states, was examined. In order to achieve the most comprehensive characterization of the

  17. Study and optimization of negative polarity rod pinch diode as flash radiography source at 4.5 MV

    Energy Technology Data Exchange (ETDEWEB)

    Etchessahar, Bertrand; Bicrel, Beatrice; Cassany, Bruno; Desanlis, Thierry; Voisin, Luc; Hebert, David [CEA, DAM, CESTA, F-33114 Le Barp (France); Bernigaud, Virgile; Magnin, Laurent; Nicolas, Remi; Poulet, Frederic; Tailleur, Yaeel [CEA, DAM, VALDUC, F-21120 Is sur Tille (France); Caron, Michel; Cartier, Frederic; Cartier, Stephanie; Hourdin, Laurent; Rosol, Rodolphe; Toury, Martial; Delbos, Christophe; Garrigues, Alain; Soleilhavoup, Isabelle [CEA, DAM, GRAMAT, F-46500 Gramat (France); and others

    2012-09-15

    The negative polarity rod pinch diode (NPRPD) is a potential millimeter spot size radiography source for high voltage generators (4 to 8 MV) [Cooperstein et al., 'Considerations of rod-pinch diode operation in negative polarity for radiography,' in Proceedings of the 14th IEEE Pulsed Power Conference, 2003, pp. 975-978]. The NPRPD consists of a small diameter (few mm) cylindrical anode extending from the front end of the vacuum cell through a thin annular cathode, held by a central conductor. The polarity has been inverted when compared to the original rod pinch diode [Cooperstein et al., 'Theoretical modeling and experimental characterization of a rod-pinch diode,' Phys. Plasmas 8(10), 4618-4636 (2001)] in order to take advantage from the maximal x-ray emission toward the anode holder at such a voltage [Swanekamp et al., 'Evaluation of self-magnetically pinched diodes up to 10 MV as high resolution flash X-ray sources,' IEEE Trans. Plasma Sci. 32(5), 2004-2016 (2004). We have studied this diode at 4.5 MV, driven by the ASTERIX generator [Raboisson et al., 'ASTERIX, a high intensity X-ray generator,' in Proceedings of the 7th IEEE Pulsed Power Conference, 1989, pp. 567-570.]. This generator, made up of a capacitor bank and a Blumlein line, was initially designed to test the behavior of electronic devices under irradiation. In our experiments, the vacuum diode has been modified in order to set up flash a radiographic diode [Etchessahar et al., 'Negative polarity rod pinch diode experiments on the ASTERIX generator,' in Conference Records-Abstracts, 37th IEEE International Conference on Plasma Science, 2010]. The experiments and numerical simulations presented here allowed the observation and analysis of various physical phenomena associated with the diode operation. Also, the influence of several experimental parameters, such as cathode and anode diameters, materials and surface states, was examined. In order to

  18. On the Connection of Gamma-Ray Bursts and X-Ray Flashes in the BATSE and RHESSI Databases

    CERN Document Server

    Řípa, Jakub

    2016-01-01

    Classification of gamma-ray bursts (GRBs) into groups has been intensively studied by various statistical tests in previous years. It has been suggested that there was a distinct group of GRBs, beyond the long and short ones, with intermediate durations. However, such a group is not securely confirmed yet. Strangely, concerning the spectral hardness, the observations from the Swift and RHESSI satellites give different results. For the Swift/BAT database it is found that the intermediate-duration bursts might well be related to so-called X-ray flashes (XRFs). On the other hand, for the RHESSI dataset the intermediate-duration bursts seem to be spectrally too hard to be given by XRFs. The connection of the intermediate-duration bursts and XRFs for the BATSE database is not clear as well. The purpose of this article is to check the relation between XRFs and GRBs for the BATSE and RHESSI databases, respectively. We use an empirical definition of XRFs introduced by other authors earlier. For the RHESSI database we...

  19. Flash X-ray cinematography analysis of dwell and penetration of small caliber projectiles with three types of SiC ceramics

    Directory of Open Access Journals (Sweden)

    Elmar Strassburger

    2016-06-01

    Full Text Available In order to improve the performance of ceramic composite armor it is essential to know the mechanisms during each phase of the projectile–target interaction and their influence on the penetration resistance. Since the view on the crater zone and the tip of a projectile penetrating a ceramic is rapidly getting obscured by damaged material, a flash X-ray technique has to be applied in order to visualize projectile penetration. For this purpose, usually several flash X-ray tubes are arranged around the target and the radiographs are recorded on film. At EMI a flash X-ray imaging method has been developed, which provides up to eight flash radiographs in one experiment. A multi-anode 450 kV flash X-ray tube is utilized with this method. The radiation transmitted through the target is then detected on a fluorescent screen. The fluorescent screen converts the radiograph into an image in the visible wavelength range, which is photographed by means of a high-speed camera. This technique has been applied to visualize and analyze the penetration of 7.62 mm AP projectiles into three different types of SiC ceramics. Two commercial SiC grades and MICASIC (Metal Infiltrated Carbon derived SiC, a C-SiSiC ceramic developed by DLR, have been studied. The influences, not only of the ceramic but also the backing material, on dwell time and projectile erosion have been studied. Penetration curves have been determined and their relevance to the ballistic resistance is discussed.

  20. In-situ visualization of N2 evolution in operating direct hydrazine hydrate fuel cell by soft X-ray radiography

    Science.gov (United States)

    Sakamoto, Tomokazu; Deevanhxay, Phengxay; Asazawa, Koichiro; Tsushima, Shohji; Hirai, Shuichiro; Tanaka, Hirohisa

    2014-04-01

    Soft X-ray radiography technique was firstly applied to operating direct hydrazine hydrate fuel cell (DHFCs) in order to visualize N2 gas behaviors with high spatial and temporal resolution. Two different cells for in-situ visualization of N2 gas in the DHFCs in in-plane and through-plane direction were designed and fabricated. The utilization of soft X-ray made the visualization of generated N2 behavior in the DHFC possible with the spatial resolution of 1.5 μm and the temporal resolution of 2.0 s frame-1. In the in-plane visualization, the inhomogeneous N2 gas distribution, suggesting non-uniform reaction distribution in the anode of DHFC, was observed. In the through-plane visualization, N2 gas accumulation under the rib of anode and discharge to the channel was clearly observed, which are related with cell performance instability.

  1. Muskuloskeletal radiography as a specialty. A quality improvement project on positioning of musculoskeletal x-rays with a multimethodology and multidisciplinary approach

    DEFF Research Database (Denmark)

    Jensen, Janni; Torfing, Trine

    of quality and to measure continuous improvement by means of audits subdividing quality from 1-4 (1=perfect and 4=inadequate , should have been repeated). Involved personnel: radiographers, reporting radiographers, radiologists and orthopedics. Various methods are applied continuously involving all...... radiographers specialized in muskuloskeletal radiography. Methods applied: • Audits are performed regularly by three alternating radiographers • Short educational sessions for radiographers on positioning and pathology are given and repeated regularly in the department by reporting radiographers • Morning...... to improve quality substantially. The number of inadequate wrist x-rays were reduced with 50% between the two first audits (one month apart) but subsequent audits (five months apart) showed improvement of wrist x-rays reduced to 20% when compared to baseline audit. Including all audits on all anatomies...

  2. A technique for estimating one-dimensional diffusion coefficients in low-permeability sedimentary rock using X-ray radiography: comparison with through-diffusion measurements.

    Science.gov (United States)

    Cavé, Lisa; Al, Tom; Xiang, Yan; Vilks, Peter

    2009-01-07

    The measurement of diffusive properties of low-permeability rocks is of interest to the nuclear power industry, which is considering the option of deep geologic repositories for management of radioactive waste. We present a simple, non-destructive, constant source in-diffusion method for estimating one-dimensional pore diffusion coefficients (D(p)) in geologic materials based on X-ray radiography. Changes in X-ray absorption coefficient (Deltamicro) are used to quantify changes in relative concentration (C/C(0)) of an X-ray attenuating iodide tracer as the tracer solution diffuses through the rock pores. Estimated values of D(p) are then obtained by fitting an analytical solution to the measured concentration profiles over time. Measurements on samples before and after saturation with iodide can also be used to determine iodide-accessible porosity (phi(I)). To evaluate the radiography method, results were compared with traditional steady-state through-diffusion measurements on two rock types: shale and limestone. Values of D(p) of (4.8+/-2.5)x10(-11) m(2).s(-1) (mean+/-standard deviation) were measured for samples of Queenston Formation shale and (2.6+/-1.0)x10(-11) m(2).s(-1) for samples of Cobourg Formation limestone using the radiography method. The range of results for each rock type agree well with D(p) values of (4.6+/-2.0)x10(-11) m(2).s(-1) for shale and (3.5+/-1.8)x10(-11) m(2).s(-1) for limestone, calculated from through-diffusion experiments on adjacent rock samples. Low porosity (0.01 to 0.03) and heterogeneous distribution of porosity in the Cobourg Formation may be responsible for the slightly poorer agreement between radiography and through-diffusion results for limestones. Mean values of phi(I) for shales (0.060) and limestones (0.028) were close to mean porosity measurements made on bulk samples by the independent water loss technique (0.062 and 0.020 for shales and limestones, respectively). Radiography measurements offer the advantage of time

  3. In situ liquid water visualization in polymer electrolyte membrane fuel cells with high resolution synchrotron x-ray radiography

    Energy Technology Data Exchange (ETDEWEB)

    Chevalier, S.; Banerjee, R.; Lee, J.; Ge, N.; Lee, C.; Bazylak, A., E-mail: abazylak@mie.utoronto.ca [Dept. of Mechanical & Industrial Engineering, Faculty of Applied Science & Engineering, University of Toronto, Toronto, Ontario (Canada); Wysokinski, T. W.; Belev, G.; Webb, A.; Miller, D.; Zhu, N. [Canadian Light Source, Saskatoon, Saskatchewan (Canada); Tabuchi, Y.; Kotaka, T. [EV System Laboratory, Research Division 2, Nissan Motor Co., Ltd., Yokosuka, Kanagawa (Japan)

    2016-07-27

    In this work, we investigated the dominating properties of the porous materials that impact water dynamics in a polymer electrolyte membrane fuel cell (PEMFC). Visualizations of liquid water in an operating PEMFC were performed at the Canadian Light Source. A miniature fuel cell was specifically designed for X-ray imaging investigations, and an in-house image processing algorithm based on the Beer-Lambert law was developed to extract quantities of liquid water thicknesses (cm) from raw X-ray radiographs. The X-ray attenuation coefficient of water at 24 keV was measured with a calibration device to ensure accurate measurements of the liquid water thicknesses. From this experiment, the through plane distribution of the liquid water in the fuel cell was obtained.

  4. Single-shot radiography using X-rays from Compton-backscattering with laser-wakefield accelerated electron beams

    CERN Document Server

    Döpp, A; Thaury, C; Gautier, J; Andriyash, I; Lifschitz, A; Goddet, J-P; Tafzi, A; Malka, V; Rousse, A; Phuoc, K Ta

    2015-01-01

    We present results from the production of high energy femtosecond X-rays by Compton-backscattering of an intense femtosecond laser pulse with quasi-monoenergetic laser-accelerated electron beams using a plasma mirror. In our parameter regime electrons of $\\sim$ 150 MeV peak energy emit a high energy radiation beam with a broad spectrum extending up to $\\sim$ 500 keV. The photon yield from the source is sufficiently high to illuminate a centimeter-size sample placed 90 centimeters behind the source and record a single-shot radiograph. The small diameter of the laser-accelerated electron beams translates into a micrometer X-ray source size, making it a promising candidate for advanced X-ray imaging techniques as e.g. propagation-based phase contrast imaging.

  5. Neutron radiography and X-ray computed tomography for quantifying weathering and water uptake processes inside porous limestone used as building material

    Energy Technology Data Exchange (ETDEWEB)

    Dewanckele, J., E-mail: jan.dewanckele@gmail.com [Department of Geology and Soil Science—UGCT, Ghent University, Krijgslaan 281 S8, B-9000 Ghent (Belgium); De Kock, T. [Department of Geology and Soil Science—UGCT, Ghent University, Krijgslaan 281 S8, B-9000 Ghent (Belgium); Fronteau, G. [University of Reims Champagne-Ardenne (URCA), GEGENAA, EA3795 Reims (France); Derluyn, H. [Chair of Building Physics, ETH Zurich, HIL E 47.2, Wolfgang-Pauli-Strasse 15, 8093 Zürich Hönggerberg (Switzerland); Vontobel, P. [Spallation Neutron Source Division, Paul Scherrer Institut (PSI), Villigen (Switzerland); Dierick, M.; Van Hoorebeke, L. [Department of Physics and Astronomy—UGCT, Ghent University, Proeftuinstraat 86, B-9000 Ghent (Belgium); Jacobs, P.; Cnudde, V. [Department of Geology and Soil Science—UGCT, Ghent University, Krijgslaan 281 S8, B-9000 Ghent (Belgium)

    2014-02-15

    Euville and Savonnières limestones were weathered by acid test and this resulted in the formation of a gypsum crust. In order to characterize the crystallization pattern and the evolution of the pore structure below the crust, a combination of high resolution X-ray computed tomography and SEM–EDS was used. A time lapse sequence of the changing pore structure in both stones was obtained and afterwards quantified by using image analysis. The difference in weathering of both stones by the same process could be explained by the underlying microstructure and texture. Because water and moisture play a crucial role in the weathering processes, water uptake in weathered and non-weathered samples was characterized based on neutron radiography. In this way the water uptake was both visualized and quantified in function of the height of the sample and in function of time. In general, the formation of a gypsum crust on limestone slows down the initial water uptake in the materials. - Highlights: • Time lapse sequence in 3D of changing pore structures inside limestone • A combination of X-ray CT, SEM and neutron radiography was used. • Quantification of water content in function of time, height and weathering • Characterization of weathering processes due to gypsum crystallization.

  6. Radiation exposure from diagnostic radiography: an assessment of X-ray beam collimation practice in some Nigerian Hospitals

    Directory of Open Access Journals (Sweden)

    Mr. Mark C. Okeji MSc

    2010-07-01

    Full Text Available This study was carried out to evaluate the X-ray beam collimation practice, among radiographers, as a measure of radiation protection for patients undergoing radiodiagnostic investigations. Inadequate X-ray beam collimation practice was observed in all the hospitals studied. Light beam misalignment/malfunction, pressure of work and years of experience were identified as major contributory factors. There is therefore need for proper equipment maintenance, employment of adequate number of radiographers and periodic audit of work pattern and output to minimize radiation exposure to the population.

  7. TAILORING X-RAY BEAM ENERGY SPECTRUM TO ENHANCE IMAGE QUALITY OF NEW RADIOGRAPHY CONTRAST AGENTS BASED ON GD OR OTHER LANTHANIDES.

    Energy Technology Data Exchange (ETDEWEB)

    DILMANIAN,F.A.; WEINMANN,H.J.; ZHONG,Z.; BACARIAN,T.; RIGON,L.; BUTTON,T.M.; REN,B.; WU,X.Y.; ZHONG,N.; ATKINS,H.L.

    2001-02-17

    Gadovist, a 1.0-molar Gd contrast agent from Schering AG, Berlin Germany, in use in clinical MPI in Europe, was evaluated as a radiography contrast agent. In a collaboration with Brookhaven National Laboratory (BNL), Schering AG is developing several such lanthanide-based contrast agents, while BNL evaluates them using different x-my beam energy spectra. These energy spectra include a ''truly'' monochromatic beam (0.2 keV energy bandwidth) from the National Synchrotron Light Source (NSLS), BNL, tuned above the Gd K-edge, and x-ray-tube beams from different kVp settings and beam filtrations. Radiographs of rabbits' kidneys were obtained with Gadovist at the NSLS. Furthermore, a clinical radiography system was used for imaging rabbits' kidneys comparing Gadovist and Conray, an iodinated contrast agent. The study, using 74 kVp and standard Al beam filter for Conray and 66 kVp and an additional 1.5 mm Cu beam filter for Gadovist, produced comparable images for Gadovist and Conray; the injection volumes were the same, while the radiation absorbed dose for Gadovist was slightly smaller. A bent-crystal silicon monochromator operating in the Laue diffraction mode was developed and tested with a conventional x-ray tube beam; it narrows the energy spectrum to about 4 keV around the anode tungsten's Ku line. Preliminary beam-flux results indicate that the method could be implemented in clinical CT if x-ray tubes with {approximately} twice higher output become available.

  8. On the connection of gamma-ray bursts and X-ray flashes in the BATSE and RHESSI databases

    Science.gov (United States)

    Řípa, J.; Mészáros, A.

    2016-12-01

    Classification of gamma-ray bursts (GRBs) into groups has been intensively studied by various statistical tests in previous years. It has been suggested that there was a distinct group of GRBs, beyond the long and short ones, with intermediate durations. However, such a group is not securely confirmed yet. Strangely, concerning the spectral hardness, the observations from the Swift and RHESSI satellites give different results. For the Swift/BAT database it is found that the intermediate-duration bursts might well be related to so-called X-ray flashes (XRFs). On the other hand, for the RHESSI dataset the intermediate-duration bursts seem to be spectrally too hard to be given by XRFs. The connection of the intermediate-duration bursts and XRFs for the BATSE database is not clear as well. The purpose of this article is to check the relation between XRFs and GRBs for the BATSE and RHESSI databases, respectively. We use an empirical definition of XRFs introduced by other authors earlier. For the RHESSI database we also use a transformation between the detected counts and the fluences based on the simulated detector response function. The purpose is to compare the hardnesses of GRBs with the definition of XRFs. There is a 1.3-4.2 % fraction of XRFs in the whole BATSE database. The vast majority of the BATSE short bursts are not XRFs because only 0.7-5.7 % of the short bursts can be given by XRFs. However, there is a large uncertainty in the fraction of XRFs among the intermediate-duration bursts. The fraction of 1-85 % of the BATSE intermediate-duration bursts can be related to XRFs. For the long bursts this fraction is between 1.0 % and 3.4 %. The uncertainties in these fractions are large, however it can be claimed that all BATSE intermediate-duration bursts cannot be given by XRFs. At least 79 % of RHESSI short bursts, at least 53 % of RHESSI intermediate-duration bursts, and at least 45 % of RHESSI long bursts should not be given by XRFs. A simulation of XRFs

  9. EFFECTS OF X-RAY BEAM ANGLE AND GEOMETRIC DISTORTION ON WIDTH OF EQUINE THORACOLUMBAR INTERSPINOUS SPACES USING RADIOGRAPHY AND COMPUTED TOMOGRAPHY-A CADAVERIC STUDY.

    Science.gov (United States)

    Djernaes, Julie D; Nielsen, Jon V; Berg, Lise C

    2017-03-01

    The widths of spaces between the thoracolumbar processi spinosi (interspinous spaces) are frequently assessed using radiography in sports horses; however effects of varying X-ray beam angles and geometric distortion have not been previously described. The aim of this prospective, observational study was to determine whether X-ray beam angle has an effect on apparent widths of interspinous spaces. Thoracolumbar spine specimens were collected from six equine cadavers and left-right lateral radiographs and sagittal and dorsal reconstructed computed tomographic (CT) images were acquired. Sequential radiographs were acquired with each interspinous space in focus. Measurements were performed for each interspinous space in the focus position and up to eight angled positions as the interspinous space moved away from focus (±). Focus position measurements were compared to matching sagittal CT measurements. Effect of geometric distortion was evaluated by comparing the interspinous space in radiographs with sagittal and dorsal reconstructed CT images. A total of 49 interspinous spaces were sampled, yielding 274 measurements. X-ray beam angle significantly affected measured width of interspinous spaces in position +3 (P = 0.038). Changes in width did not follow a consistent pattern. Interspinous space widths in focus position were significantly smaller in radiographs compared to matching reconstructed CT images for backs diagnosed with kissing spine syndrome (P Geometric distortion markedly affected appearance of interspinous space width between planes. In conclusion, X-ray beam angle and geometric distortion influence radiographically measured widths of interspinous spaces in the equine thoracolumbar spine, and this should be taken into consideration when evaluating sport horses. © 2016 American College of Veterinary Radiology.

  10. Characterization of the external and internal flow structure of an aerated-liquid injector using X-ray radiography and fluorescence

    Science.gov (United States)

    Peltier, Scott J.; Lin, Kuo-Cheng; Carter, Campbell D.; Kastengren, Alan L.

    2017-09-01

    In the present study, the internal flowfield of aerated-liquid fuel injectors is examined through X-ray radiography and X-ray fluorescence. An inside- out injector, consisting of a perforated aerating tube within an annular liquid stream, sprays into a quiescent environment at a fixed mass flow rate of water and nitrogen gas. The liquid is doped with bromine (in the form of NaBr) to create an X-ray fluorescence signal. This allows for reasonable absorption and fluorescence signals, and one or both diagnostics can be used to track the liquid distribution. The injector housing is fabricated from beryllium (Be), which allows the internal flowfield to be examined (as Be has relatively low X-ray attenuation coefficient). Two injector geometries are compared, illustrating the effects of aerating orifice size and location on the flow evolution. Time-averaged equivalent pathlength and line-of-sight averaged density ρ( y) reveal the formation of the two-phase mixture, showing that the liquid film thickness along the injector walls is a function of the aerating tube geometry, though only upstream of the nozzle. These differences in gas and liquid distribution (between injectors with different aerating tube designs) are suppressed as the mixture traverses the nozzle contraction. The averaged liquid velocity (computed from the density and liquid mass flow rate) reveals a similar trend. This suggests that at least for the current configurations, the plume width, liquid mass distribution, and averaged liquid velocity for the time-averaged external spray are insensitive to the aerating tube geometry.

  11. Low contrast detectability and dose savings with an amorphous silicon detector designed for x-ray radiography

    Science.gov (United States)

    Xue, Ping; Schubert, Scott F.; Aufrichtig, Richard

    2000-04-01

    In an observer study we compare low contrast detectability and dose efficiency of an amorphous silicon x-ray detector versus a standard thoracic screen-film (Kodak InSight HC/InSight IT). Twelve images of a CDRAD contrast-detail phantom were acquired with the screen-film system using an entrance exposure corresponding to a conventional chest x-ray. Using the same x- ray system with an interchanged digital detector, we acquired four digital image sets (12 images each) at dose levels corresponding to 27%, 41%, 63% and 100% of the film dose. Prior to laser printing, the digital images were processed to match the film contrast and optical density level. A 4- alternative forced choice (4-AFC) paradigm with seven observers was used to measure the threshold contrasts of disk sizes from 0.5 to 4.0 mm. Further, we estimated the equivalent perceptual dose (EPD), which is the dose level of digital for which the same contrast detectability as film is obtained. Contrast detectability is significantly improved with the digital detector. On average, all disk shaped objects detected from the digital detector have lower threshold contrasts than those from film at the same dose level. The EPD value averaged over disk size is 44%, which corresponds to a 56% dose savings for the digital detector.

  12. Investigation of failure mechanisms in silicon based half cells during the first cycle by micro X-ray tomography and radiography

    Science.gov (United States)

    Sun, Fu; Markötter, Henning; Dong, Kang; Manke, Ingo; Hilger, Andre; Kardjilov, Nikolay; Banhart, John

    2016-07-01

    Two proof-of-concept batteries were designed and prepared for X-ray microtomography and radiography characterizations to investigate the degradation mechanisms of silicon (Si) based half cells during the first cycle. It is highlighted here for the first time that, apart from the significant volume expansion-induced pulverization, the electrochemical "deactivation" mechanism contributes significantly to the capacity loss during the first charge process. In addition, the unexpected electrochemically inactive Si particles are also believed to substantially decrease the energy density due to the inefficient utilization of loaded active material. These unexpected findings, which cannot be deduced from macroscopic electrochemical characterizations, expand the inherent explanations for performance deterioration of Si-anode material based lithium ion batteries (LIBs) and emphasize the vital value of microscopic techniques in revealing the correlation between macroscopic electrode structure and the overall electrochemical performance.

  13. Digital Slot Radiography Based On A Linear X-Ray Image Intensifier And Two-Dimensional Image Sensors.

    Science.gov (United States)

    Beerlage, M. J. M.; Levels, H. P. L.; Mulder, H.

    1986-06-01

    Apart from providing the inherent benefits of digital imaging, a digital chest system should preferably be superior to large-size film with respect to diagnostic quality. Systems, demonstrated until now, tend to fail in that respect. Here we describe a system -under development- that combines the advantages of film (e.g. high resolution), area detectors (wide sensor dynamic range) and slit detectors (efficient reduction of scattered radiation, high contrast resolution and instantaneous image availibility). Thereby the system is low-dose, compact and operating at standard X-ray tube loading.

  14. Light emission efficiency and imaging performance of Gd2O2S: Eu powder scintillator under x-ray radiography conditions.

    Science.gov (United States)

    Michail, C M; Fountos, G P; Liaparinos, P F; Kalyvas, N E; Valais, I; Kandarakis, I S; Panayiotakis, G S

    2010-07-01

    To evaluate Gd2O2S:Eu powder phosphor as a radiographic image receptor and to compare it to phosphors often used in radiography. Gd2O2S:Eu is nonhygroscopic, emitting red light with decay time close to that of Gd2O2S:Tb. The light intensity emitted per unit of x-ray exposure rate (absolute luminescence efficiency) was measured for laboratory prepared screens with coating thicknesses of 33.1, 46.4, 63.1, 78.3, and 139.8 mg/cm2 and tube voltages ranging from 50 to 140 kVp. Parameters related to image quality such as the modulation transfer function (MTF) and the detective quantum efficiency (DQE) were also experimentally examined. In addition, a previously validated Monte Carlo code was used to estimate intrinsic x-ray absorption and optical properties, as well as the MTF and the Swank factor (I) of the Gd2O2S:Eu scintillators. Gd2O2S:Eu light intensity was found higher than that of single CsI:T1 crystal for tube voltages up to 100 kVp. The MTF and the DQE were found to be comparable with those of Gd2O2S:Tb and CsI:T1 screens. MTF estimated by the Monte Carlo code was found very close to the experimental MTF values. Gd2O2S:Eu showed peak emission in the wavelength range 620-630 nm. Its emission spectrum was excellently matched to various optical detectors (photodiodes, photocathodes, CCDs, and CMOS) employed in flat panel detectors. Gd2O2S:Eu is an efficient phosphor potentially well suited to radiography and especially to some digital detectors sensitive to red light.

  15. Bright Flash Neutron Radiography at the McClellan Nuclear Research Reactor

    Science.gov (United States)

    Lerche, M.; Tremsin, A. S.; Schillinger, B.

    The University of California, Davis McClellan Nuclear Research Center (MNRC) operates a 2 MW TRIGATM reactor, which is currently the highest power TRIGATM reactor in the United States. The Center was originally build by the US Air Force to detect hidden defects in aircraft structures using neutron radiography; the Center can accommodate samples as large as 10.00 m long, 3.65 m high, and weighing up to 2,270 kg. The MNRC reactor can be pulsed to 350 MW for about 30 ms (FWHM). The combination of a short neutron pulse with a fast microchannel plate based neutron detector enables high-resolution flash neutron radiography to complement conventional neutron radiography

  16. Non-destructive analysis of ancient bimetal swords from western Asia by γ-ray radiography and X-ray fluorescence

    Science.gov (United States)

    Shizuma, Kiyoshi; Kajimoto, Tsuyoshi; Endo, Satoru; Matsugi, Kazuhiro; Arimatsu, Yui; Nojima, Hisashi

    2017-09-01

    Eight ancient bimetal swords held by Hiroshima University, Japan were analyzed non-destructively through γ-ray radiography and X-ray fluorescence (XRF). 137Cs and 60Co γ-ray irradiation sources were used to obtain transmission images of swords. A scanning radiography method using a 60Co γ-ray source was developed. XRF was used for qualitative elemental analysis of the swords. The presence of iron cores in the hilts of some swords had been observed and it was assumed that the cores were a ritual symbol or had a functional purpose. However, our work reveals that these swords were originally bronze-hilted iron swords and that the rusty blades were replaced with bronze blades to maintain the swords' commercial value as an antique. Consequently, the rest of the iron blade was left in the hilt as an iron tang. The junction of the blade and the guard was soldered and painted to match the patina color. XRF analysis clearly showed that the elemental Sn/Cu ratios of the blades and the hilts were different. These findings are useful for clarifying the later modifications of the swords and are important for interpreting Bronze Age and Iron Age history correctly.

  17. Development of profession and quality in radiography with focus on evaluation criteria and image quality of chest x-rays

    DEFF Research Database (Denmark)

    Debess, Jeanne; Thomsen, Henrik; Conradsen, Jacob

    2011-01-01

    Learning Objectives: Learning Objectives: To improve quality of chest xrays by Education Conferences for radiographers and evaluation of image quality. Background: Introduction of digital imaging technology and picture archiving and communication system (PACS) has changed the workflow in the x......-ray department including evaluation of image quality and feedback from radiologist to radiographer. Imaging Findings or Procedure Details: Procedure Details: Data for evaluation of image quality was collected by questionnaires aimed at: anatomy, image-focusing, image-collimation, exposure and body habitus...... collection were found. Evaluation results from anatomy, image-focusing, image-collimation and exposure from first data collection shows variations from 7 % to 37 % between evaluation at primary monitor by the radiographers and diagnostic monitor by the radiologist. In relation to anatomy, the quality...

  18. Development of Portable Digital Radiography System with a Device for Monitoring X-ray Source-Detector Angle and Its Application in Chest Imaging

    Directory of Open Access Journals (Sweden)

    Tae-Hoon Kim

    2017-03-01

    Full Text Available This study developed a device measuring the X-ray source-detector angle (SDA and evaluated the imaging performance for diagnosing chest images. The SDA device consisted of Arduino, an accelerometer and gyro sensor, and a Bluetooth module. The SDA values were compared with the values of a digital angle meter. The performance of the portable digital radiography (PDR was evaluated using the signal-to-noise (SNR, contrast-to-noise ratio (CNR, spatial resolution, distortion and entrance surface dose (ESD. According to different angle degrees, five anatomical landmarks were assessed using a five-point scale. The mean SNR and CNR were 182.47 and 141.43. The spatial resolution and ESD were 3.17 lp/mm (157 μm and 0.266 mGy. The angle values of the SDA device were not significantly difference as compared to those of the digital angle meter. In chest imaging, the SNR and CNR values were not significantly different according to the different angle degrees. The visibility scores of the border of the heart, the fifth rib and the scapula showed significant differences according to different angles (p < 0.05, whereas the scores of the clavicle and first rib were not significant. It is noticeable that the increase in the SDA degree was consistent with the increases of the distortion and visibility score. The proposed PDR with a SDA device would be useful for application in the clinical radiography setting according to the standard radiography guidelines.

  19. Characterization of the self magnetic pinch diode at high voltages for flash radiography.

    Energy Technology Data Exchange (ETDEWEB)

    Cordova, Steve Ray; Portillo, Salvador; Oliver, Bryan Velten; Threadgold, James R. (Atomic Weapons Establishment Aldermaston, Reading Berkshire, U.K.); Crotch, Ian (Atomic Weapons Establishment Aldermaston, Reading Berkshire, U.K.); Ziska, Derek Raymond

    2008-10-01

    The Sandia Laboratories Advanced Radiographic Technologies Department, in collaboration with the United Kingdom Atomic Weapons Establishment, has been conducting research into the development of the Self-Magnetic-Pinched diode as an x-ray source suitable for flash radiographic experiments. We have demonstrated that this source is capable of meeting and exceeding the initial requirements of 250 rads (measured at one meter) with a 2.75 mm source spot-size. Recent experiments conducted on the RITS-6 accelerator have demonstrated the ability of this diode to meet intermediate requirements with a sub 3 mm source spot size and a dose in excess of 400 rads at one meter.

  20. Identification of pulpitis at dental X-ray periapical radiography based on edge detection, texture description and artificial neural networks

    Directory of Open Access Journals (Sweden)

    Bernard Y Tumbelaka

    2014-01-01

    Full Text Available Objectives: The aim of the present research was to identify pulpitis through periapical radiography by applying edges as basis image features, the texture description and the artificial neural networks (ANNs. Materials and Methods: Input image data records of 10 molar and 10 canine teeth were used. The clinical diagnosis of interest cases were represented as normal pulp, reversible and irreversible pulpitis, and necrotic pulp. The following image processing steps were done. First, the data records were converted digitally and preprocessed as its original image using the Gaussian Filter to obtain the best smoothed intensity distribution. Second, the local image differentiation was used to produce edge detector operators, e(x,y as the image gradient; ∇f(x,y providing useful information about the local intensity variations. Third, these results were analyzed by using the texture descriptors to obtain digitally the image entropy, H. The fourth step, all were characterized by the ANNs. Results: The edge detection carried important information about the object boundaries of pulpal health and pain conditions in the dental pulp significantly. The image entropy which was identified, the diagnostic term, was obtained from texture descriptors in the segmentation regions where the curves of pulp states tent convergence with the normal pulp line from 4.9014 to 4.6843 decreasing to the reversible and the irreversible pulpitis line include the nectrotic pulp line from 4.6812 to 4.5926 and then inputting to the ANNs analysis at the same of mean square error around 0.0003. Conclusions: Referred to these results, the correlation of the image entropy and the ANNs analysis could be linearly classified with the critical point of 4.6827. Finally, it could be concluded that the direct reading radiography is better to be digitized in order to provide us the best choice for diagnosis validation.

  1. Improved Diagnostics by Assessing the Micromorphology of Breast Calcifications via X-Ray Dark-Field Radiography

    Science.gov (United States)

    Scherer, Kai; Braig, Eva; Ehn, Sebastian; Schock, Jonathan; Wolf, Johannes; Birnbacher, Lorenz; Chabior, Michael; Herzen, Julia; Mayr, Doris; Grandl, Susanne; Sztrókay-Gaul, Anikó; Hellerhoff, Karin; Pfeiffer, Franz

    2016-11-01

    Breast microcalcifications play an essential role in the detection and evaluation of early breast cancer in clinical diagnostics. However, in digital mammography, microcalcifications are merely graded with respect to their global appearance within the mammogram, while their interior microstructure remains spatially unresolved and therefore not considered in cancer risk stratification. In this article, we exploit the sub-pixel resolution sensitivity of X-ray dark-field contrast for clinical microcalcification assessment. We demonstrate that the micromorphology, rather than chemical composition of microcalcification clusters (as hypothesised by recent literature), determines their absorption and small-angle scattering characteristics. We show that a quantitative classification of the inherent microstructure as ultra-fine, fine, pleomorphic and coarse textured is possible. Insights underlying the micromorphological nature of breast calcifications are verified by comprehensive high-resolution micro-CT measurements. We test the determined microtexture of microcalcifications as an indicator for malignancy and demonstrate its potential to improve breast cancer diagnosis, by providing a non-invasive tool for sub-resolution microcalcification assessment. Our results indicate that dark-field imaging of microcalcifications may enhance the diagnostic validity of current microcalcification analysis and reduce the number of invasive procedures.

  2. In situ and real-time analysis of the growth and interaction of equiaxed grains by synchrotron X- ray radiography

    Science.gov (United States)

    Bogno, A.; Nguyen-Thi, H.; Billia, B.; Reinhart, G.; Mangelinck-Noël, N.; Bergeon, N.; Schenk, T.; Baruchel, J.

    2012-01-01

    The phenomena involved during equiaxed growth are dynamic, so that in situ and real-time investigation by X-ray imaging is compulsory to fully analyse the microstructure formation. The experiments on Al - 10 wt% Cu alloy of this paper are carried out at the European Synchrotron Radiation Facility (ESRF) in Grenoble (France). Equiaxed growth was achieved in nearly isothermal conditions and continuously monitored from the very early stages of solidification to an asymptotic state. First, measurements of dendrite arms velocity for a same grain showed slight differences in the early stages of the growth. This effect is attributed to a gravity-related "self - poisoning" of the grain. Then, the propagation of primary dendrite arms was analysed and two successive growth regimes were observed. First, due to the relative distance with neighbour grains, each grain could be considered as isolated (i.e. growing freely) and tip growth rate gradually increased. In a subsequent phase, tip growth rate slowly decreased towards zero, due to the proximity of neighbouring grains. Using an image analysis technique, we were able to measure the solute profiles in the liquid phase between interacting arms. These measurements confirmed that solutal impingement is responsible for stopping the grain growth.

  3. Experimental study of the X-ray spectra optimization for computed radiography mammography systems; Investigacao experimental da otimizacao do espectro de raios X em sistemas de mamografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Tomal, Alessandra, E-mail: atomal@ifi.unicamp.br [Universidade Estadual de Campinas (UNICAMP), Campinas, SP (Brazil). Instituto de Fisica Gleb Wataghin; Cunha, Diego M. [Universidade Federal de Uberlandia (UFU), Uberlandia, MG (Brazil). Instituto de Fisica; Nogueira, Maria S. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Gaspar, Fabio [Vigilancia Sanitaria, Campinas, SP (Brazil); Poletti, Martin E. [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras. Departamento de Fisica

    2013-12-15

    Digital mammography is replacing screen-film mammography due to several advantages of digital receptors. The use of Computed Radiography (CR) mammography systems has been considered an alternative to achieve digital images with a low cost. Besides, the optimization of the X-ray spectrum, characterized by the anode/filter combination and tube potential, is an important step in order to improve the image quality with the lower dose to the breast. In this work, we investigated the optimal X-ray spectra using a figure of merit for two mammography equipment: Senographe DMR (General Electric Medical Systems) and Mammomat 3000 Nova (Siemens), both using an image plate Kodak EHR-M2 (Kodak DirectView). A PMMA phantom, simulating breast with thicknesses of 5 cm, was used. The anode/filter combinations evaluated were: Mo/Mo, Mo/Rh, Rh/Rh and Rh/Al for the Senographe system, and Mo/Mo, Mo/Rh, W/Rh for the Mammomat system, for all the intervals of tube potential range from 24 to 35 kVp. Results demonstrate that the higher values of FOM were achieved with the Rh/Rh at 29 kVp and Rh/Al at 26 kVp for the Senographe system, and for the W/Rh at 28 kVp in the Mammomat one. The reduction in the dose associated with the optimum spectra was 13 and 26% for the Senographe and Mammomat systems, respectively. Finally, our results suggest that anode/filter combinations of more energetic spectra than the standard Mo/Mo combination are recommended for thicker breast, in order to reduce the breast dose levels. (author)

  4. X-Ray Protection

    Science.gov (United States)

    1955-01-01

    15,000. • When developed In Kodak liquid X-ray developer for 5 min at a temperature of 200 C. b Film sensitivities vary with photon energy by the...for example temporomandibular -joint exposures where a skin dose of 25 r or more may be obtained during a single exposure with 65 kvp, 1.5 mm aluminum...communication. W. J. Updegrave, Temporomandibular articulation-X-ray examina- tion, Dental Radiography and Photography 26, No. 3, 41 (1953). H. 0. Wyckoff, R. J

  5. Local liquid velocity measurement in trickle bed reactors (TBRs) using the x-ray digital industrial radiography (DIR) technique

    Science.gov (United States)

    Anuar Mohd Salleh, Khairul; Lee, Hyoung Koo; Al-Dahhan, Muthanna H.

    2014-01-01

    This work describes the development of a new technique to measure local liquid velocity (VLL) for multiphase flows in trickle bed reactors (TBRs) (gas-liquid-solid system). In the studied TBR, the liquid phase is represented by water, gas by air and 3 mm expanded polystyrene beads as the solid packing. Three different superficial liquid velocities (VSL) and a constant superficial gas velocity (VSG) were used in the packed bed with an internal diameter of 4.25 cm. While the liquid is moving into the packed bed, tracking particles of 106-125 μm diameter (16.45% difference) are injected. The movement of the tracking particles is monitored and digitally recorded by a complementary metal-oxide-semiconductor detector. In this experiment, x-rays were used as the radiation source. Four replications were made with fresh packing. Comparable observations can be found from other published techniques (i.e. magnetic resonance imaging). Results from this study indicate that, at VSL = 0.13 cm s-1, the measured VLL can reach up to 51 times that of its VSL, while for VSL = 0.27 cm s-1, the measured VLL reached up to 35 times higher than the VSL and for VSL = 0.39 cm s-1, the VLL reached up to 39.8 times higher than its VSL. Through statistical analysis, the implementation of such a method is found to be reproducible throughout the experiments. The mean per cent difference in the measured VLL was 10% and 5% for lower implemented VSL of 0.13 and 0.27 cm s-1, respectively. At higher VSL (0.39 cm s-1), the particle tracer was greatly distributed and carried away by the high liquid flow rate. The variance or the range of the measured VLL does not vary for all replications in every VSL, which confirms the reproducibility of the experimental measurements, regardless of the VSL.

  6. Note: On the generation of sub-300 keV flash-X-rays using rod-pinch diode: An experimental investigation

    Energy Technology Data Exchange (ETDEWEB)

    Satyanarayana, N.; Rajawat, R. K.; Basu, Shibaji [Facility for Electromagnetic Systems, BARCF(V), B-Block, Autonagar, Visakhapatnam 530012, Andhra Pradesh (India); Rao, A. Durga Prasad [Department of Nuclear Physics, Andhra University, Visakhapatnam 530001, Andhra Pradesh (India); Mittal, K. C. [Accelerator and Pulse Power Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085, Maharashtra (India)

    2014-09-15

    Generation of flash X-rays (FXRs) at less than 500 keV is described with emphasis on experimental investigation. The pulser is a Tesla transformer-Water transmission line based pulsed power generator operating in double resonance mode to power a rod-pinch diode. The configuration of aspect ratio reported here falls much below the normally reported ratios for the rod-pinch diode operation. Experimental investigation at such low pulsed voltage has revealed “flowering” of the anode tip and “pitting” of the perspex window. A possible explanation in terms of Lorentz body force is discussed rather than the pinch mechanism generally suggested in literature. The experimental investigation for the FXR generation is corroborated by measuring the radiation dose using CaSO{sub 4} (Dy) thermo luminescent dosimeters.

  7. In situ measurement of interfacial tension of Fe-S and Fe-P liquids under high pressure using X-ray radiography and tomography techniques

    Science.gov (United States)

    Terasaki, H.; Urakawa, S.; Funakoshi, K.; Nishiyama, N.; Wang, Y.; Nishida, K.; Sakamaki, T.; Suzuki, A.; Ohtani, E.

    2009-05-01

    Interfacial tension is one of the most important properties of the liquid iron alloy that controls the core formation process in the early history of the Earth and planets. In this study, we made high-pressure X-ray radiography and micro-tomography measurements to determine the interfacial tension between liquid iron alloys and silicate melt using the sessile drop method. The measured interfacial tension of liquid Fe-S decreased significantly (802-112 mN/m) with increasing sulphur content (0-40 at%) at 1.5 GPa. In contrast, the phosphorus content of Fe had an almost negligible effect on the interfacial tension of liquid iron. These tendencies in the effects of light elements are consistent with those measured at ambient pressure. Our results suggest that the effect of sulphur content on the interfacial tension of liquid Fe-S (690 mN/m reduction with the addition of 40 at% S) is large compared with the effect of temperature (˜273 mN/m reduction with an increase of 200 K). The three-dimensional structure of liquid Fe-S was obtained at ˜2 GPa and 1373-1873 K with a high-pressure tomography technique. The Fe-S droplet was quite homogeneous when evaluated in a slice of the three-dimensional image.

  8. The tendency of medical electrical equipment - IEC 60601-2-54: Particular requirements for the basic safety and essential performance of x-ray equipment for radiography and radioscopy

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Young Hoon; Kim, Jung Min [Dept. of Nuclear Engineering and Radiologic Science School of Health and Environmental Science College of Health Science, Korea University, Seoul (Korea, Republic of)

    2015-12-15

    Medical electrical equipment - Part 1: General requirement for basic safety and essential performance of MFDS was revised as 3th edition and Medical electrical equipment Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment will be expected to be announced as notification. Therefore this technical report was written to introduce provision of the particular requirements, replacement, addition, amendment. The purpose of this particular requirements is to secure requirements for basic safety and essential performance of X-ray equipment for radiography and radioscopy. X-ray high voltage generator, mechanical protective device, protection against radiation is included in this particular requirements. Medical electrical equipment - Part 1, Part 1-2, Part 1-3 is applied to this particular requirements. If the requirements is announced as notification, It is expected to widen understanding for basic safety and essential performance of X-ray equipment for radiography and radioscopy and play a part to internationalize of medical equipment.

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... little information about muscles, tendons or joints. An MRI may be more useful in identifying bone and ... bones and the spinal cord can be evaluated). MRI can also detect subtle or occult fractures or ...

  10. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... evaluation. National and international radiology protection organizations continually review and update the technique standards used by radiology ... the possible charges you will incur. Web page review process: This Web page is reviewed regularly by ...

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2017 ... message (optional): Bees: Wax: Notice: RadiologyInfo respects your privacy. Information entered here will not be used for ...

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... understanding of the possible charges you will incur. Web page review process: This Web page is reviewed regularly by a physician with ... not responsible for the content contained on the web pages found at these links. About Us | Contact ...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... assist in the detection and diagnosis of bone cancer . locate foreign objects in soft tissues around or ... Risks There is always a slight chance of cancer from excessive exposure to radiation. However, the benefit ...

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... evaluation. National and international radiology protection organizations continually review and update the technique standards used by radiology ... the possible charges you will incur. Web page review process: This Web page is reviewed regularly by ...

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... any possibility you are pregnant. Leave jewelry at home and wear loose, comfortable clothing. You may be ... emergency rooms, physician offices, ambulatory care centers, nursing homes and other locations, making it convenient for both ...

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... assist in the detection and diagnosis of bone cancer . locate foreign objects in soft tissues around or ... Risks There is always a slight chance of cancer from excessive exposure to radiation. However, the benefit ...

  17. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... reductions. look for injury, infection, arthritis , abnormal bone growths and bony changes seen in metabolic conditions. assist ... of the unaffected limb, or of a child's growth plate (where new bone is forming), for comparison ...

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... on a patient. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... fracture reductions. look for injury, infection, arthritis , abnormal bone growths and bony changes seen in metabolic conditions. assist ... of the unaffected limb, or of a child's growth plate (where new bone is forming), for comparison purposes. When the examination ...

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... taken of the unaffected limb, or of a child's growth plate (where new bone is forming), for ... around joints, and in evaluating the hips of children with congenital problems. top of page This page ...

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... not responsible for the content contained on the web pages found at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2017 Radiological Society of North America, ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... page This page was reviewed on April 06, 2016 Send us your feedback Did you find the ... Privacy | Terms of Use | Links | Site Map Copyright © 2017 Radiological Society of North America, Inc. (RSNA). To ...

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ... entered here will not be used for any purpose other than this referral.

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... 10 minutes. top of page What will I experience during and after the procedure? A bone x- ... examination itself is a painless procedure. You may experience discomfort from the cool temperature in the examination ...

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... produce pictures of any bone in the body. It is commonly used to diagnose fractured bones or ... pass through most objects, including the body. Once it is carefully aimed at the part of the ...

  6. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... image quality. top of page Who interprets the results and how do I get them? A radiologist , ... care or referring physician , who will discuss the results with you. Follow-up examinations may be necessary. ...

  7. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... views of bone, they provide little information about muscles, tendons or joints. An MRI may be more useful in identifying bone and joint injuries (e.g., meniscal and ligament tears in the knee, rotator cuff and labrum tears ...

  8. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... your doctor to view and assess bone fractures, injuries and joint abnormalities. This exam requires little to ... fusion, joint replacement and fracture reductions. look for injury, infection, arthritis , abnormal bone growths and bony changes ...

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Please note RadiologyInfo.org is not a medical facility. Please contact your physician with specific medical questions ... your community, you can search the ACR-accredited facilities database . This website does not provide cost information. ...

  10. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ... dose possible while producing the best images for evaluation. National and international radiology protection organizations continually review ...

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... offices, ambulatory care centers, nursing homes and other locations, making it convenient for both patients and physicians. ... Please note RadiologyInfo.org is not a medical facility. Please contact your physician with specific medical questions ...

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... technologist if there is any possibility you are pregnant. Leave jewelry at home and wear loose, comfortable ... if there is any possibility that they are pregnant. Many imaging tests are not performed during pregnancy ...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... images for evaluation. National and international radiology protection organizations continually review and update the technique standards used ... information you were looking for? Yes No Please type your comment or suggestion into the following text ...

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... up examinations may be necessary. Your doctor will explain the exact reason why another exam is requested. Sometimes a follow-up exam is done because a potential abnormality needs further evaluation with additional views or a ...

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... over time. Follow-up examinations are sometimes the best way to see if treatment is working or ... the lowest radiation dose possible while producing the best images for evaluation. National and international radiology protection ...

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... views of bone, they provide little information about muscles, tendons or joints. An MRI may be more useful in identifying bone and joint injuries (e.g., meniscal and ligament tears in the knee, rotator cuff and labrum tears in the shoulder) and in imaging of the spine (because both ...

  17. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Leave jewelry at home and wear loose, comfortable clothing. You may be asked to wear a gown. ... will be asked to remove some of your clothes and to wear a gown during the exam. ...

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... understanding of the possible charges you will incur. Web page review process: This Web page is reviewed regularly by a physician with expertise ... not responsible for the content contained on the web pages found at these links. About Us | Contact Us | ...

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... a radiologist or other physician. To locate a medical imaging or radiation oncology provider in your community, you can search the ACR- ... with your prescribed procedure with your doctor, the medical facility staff and/or your insurance provider to get a better understanding of the possible ...

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z ...

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... in emergency rooms, physician offices, ambulatory care centers, nursing homes and other locations, making it convenient for ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Arthritis X- ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... view and assess bone fractures, injuries and joint abnormalities. This exam requires little to no special preparation. ... follow-up exam is done because a potential abnormality needs further evaluation with additional views or a ...

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ... dose possible while producing the best images for evaluation. National and international radiology protection organizations continually review ...

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... more useful in identifying bone and joint injuries (e.g., meniscal and ligament tears in the knee, ... or suggestion into the following text box: Comment: E-mail: Area code: Phone no: Thank you! Images × ...

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... of the radiation while soft tissue, such as muscle, fat and organs, allow more of the x- ... views of bone, they provide little information about muscles, tendons or joints. An MRI may be more ...

  6. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... produce pictures of any bone in the body. It is commonly used to diagnose fractured bones or ... pass through most objects, including the body. Once it is carefully aimed at the part of the ...

  7. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... your doctor to view and assess bone fractures, injuries and joint abnormalities. This exam requires little to ... fusion, joint replacement and fracture reductions. look for injury, infection, arthritis , abnormal bone growths and bony changes ...

  8. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... This website does not provide cost information. The costs for specific medical imaging tests, treatments and procedures may vary by geographic region. Discuss the fees associated with your prescribed procedure with your doctor, the ...

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... positioning devices will be used to help you maintain the proper position. A lead apron may be ... in the shoulder) and in imaging of the spine (because both the bones and the spinal cord ...

  10. Bright flash neutron radiography capability of the research reactor at the McClellan Nuclear Research Center

    Energy Technology Data Exchange (ETDEWEB)

    Tremsin, A.S., E-mail: ast@ssl.berkeley.edu [University of California at Berkeley, Berkeley, CA 94720 (United States); Lerche, M. [McClellan Nuclear Research Center, 5335 Price Avenue Building 258, McClellan, CA 95652 (United States); Schillinger, B. [Forschungsreaktor FRM-II, Technische Universität München, D-85747 Garching (Germany); Feller, W.B. [NOVA Scientific, Inc., 10 Picker Road, Sturbridge, MA 01566 (United States)

    2014-06-01

    The capability to produce a bright, short neutron pulse at the McClellan Nuclear Research Center (MNRC) can be very attractive for some neutron imaging applications. Complementary to conventional thermal neutron radiography conducted at the reactor, operating at the average power of 1 MW, a short pulse of ∼25 ms FWHM duration can be produced at MNRC with the peak power exceeding 350 MW. Combination of a fast thermal neutron counting detector with a short neutron pulse at MNRC, enables high-resolution stroboscopic imaging to complement conventional neutron radiography. The results presented in this paper demonstrate the MNRC capabilities for conducting conventional thermal neutron radiography, demonstrating imaging spatial resolution below 100 μm, as well as bright flash neutron radiography with multiple nearly simultaneous events detected with microsecond timing resolution.

  11. X-ray today

    Energy Technology Data Exchange (ETDEWEB)

    Neitzel, U. [Philips Medical Systems, Hamburg (Germany)

    2001-09-01

    The interest attracted by the new imaging modalities tends to overshadow the continuing importance of projection radiography and fluoroscopy. Nevertheless, projection techniques still represent by far the greatest proportion of diagnostic imaging examinations, and play an essential role in the growing number of advanced interventional procedures. This article describes some of the latest developments in X-ray imaging technology, using two products from the Philips range as examples: the Integris Allura cardiovascular system with 3D image reconstruction, and the BV Pulsera: a high-end, multi-functional mobile C-arm system with cardiac capabilities. (orig.)

  12. Non-destructive imaging of fragments of historical beeswax seals using high-contrast X-ray micro-radiography and micro-tomography with large area photon-counting detector array.

    Science.gov (United States)

    Karch, Jakub; Bartl, Benjamin; Dudak, Jan; Zemlicka, Jan; Krejci, Frantisek

    2016-12-01

    Historical beeswax seals are unique cultural heritage objects. Unfortunately, a number of historical sealing waxes show a porous structure with a strong tendency to stratification and embrittlement, which makes these objects extremely prone to mechanical damage. The understanding of beeswax degradation processes therefore plays an important role in the preservation and consequent treatment of these objects. Conventional methods applied for the investigation of beeswax materials (e.g. gas chromatography) are of a destructive nature or bring only limited information about the sample surface (microscopic techniques). Considering practical limitations of conventional methods and ethical difficulties connected with the sampling of the historical material, radiation imaging methods such as X-ray micro-tomography presents a promising non-destructive tool for the onward scientific research in this field. In this contribution, we present the application of high-contrast X-ray micro-radiography and micro-tomography for the investigation of beeswax seal fragments. The method is based on the application of the large area photon-counting detector recently developed at our institute. The detector combines the advantages of single-photon counting technology with a large field of view. The method, consequently, enables imaging of relatively large objects with high geometrical magnification. In the reconstructed micro-tomographies of investigated historical beeswax seals, we are able to reveal morphological structures such as stratification, micro-cavities and micro-fractures with spatial resolution down to 5μm non-destructively and with high imaging quality. The presented work therefore demonstrates that a combination of state-of-the-art hybrid pixel semiconductor detectors and currently available micro-focus x-ray sources makes it possible to apply X-ray micro-radiography and micro-tomography as a valuable non-destructive tool for volumetric beeswax seal morphological studies

  13. Monitoring of the heavy-metal hyperaccumulation in vegetal tissues by X-ray radiography and by femto-second laser induced breakdown spectroscopy.

    Science.gov (United States)

    Kaiser, J; Samek, O; Reale, L; Liska, M; Malina, R; Ritucci, A; Poma, A; Tucci, A; Flora, F; Lai, A; Mancini, L; Tromba, G; Zanini, F; Faenov, A; Pikuz, T; Cinque, G

    2007-02-01

    This article reports on the utilization of X-ray microradiography and laser induced breakdown spectroscopy (LIBS) techniques for investigation of the metal accumulation in different part of leaf samples. The potential of the LIBS-analysis for finding the proper plant species for phytoremediation is compared with the results of microradiography measurements at the HERCULES source at ENEA, Rome (Italy) and X-ray microradiography experiments at the ELETTRA Synchrotron, Trieste (Italy).

  14. Methodological study of aging effects on fuel cells using X-ray synchrotron radiography and tomography; Methodische Untersuchung von Alterungseffekten an Brennstoffzellen mittels Synchrotronradiografie und -tomografie

    Energy Technology Data Exchange (ETDEWEB)

    Arlt, Tobias

    2012-04-05

    In the present work, new and advanced methods for the investigation of methanol and hydrogen powered fuel cells were analyzed. Synchrotron radiography and tomography were applied to investigate materials and transport processes in operating fuel cells ''in-situ'' and non-destructively. The corrosion of ruthenium is a key issue during aging of direct methanol fuel cells (DMFC). Therefore the influence of different aging processes on the distribution of ruthenium is of great interesting. An imaging method based on X-ray absorption spectroscopy (XAS) was applied to investigate the changes in the distribution of fuel cell catalysts three-dimensionally. Using monoenergetic synchrotron radiation it was shown that the distribution of ruthenium (Ru) in the anode catalyst changes after application of an accelerated aging procedure. A strong influence on the flowfield and the gas diffusion layer structures on the Ru distribution were found in the gas diffusion electrode at the anode side. Additionally some ruthenium moves through the membrane from the anode to the cathode. The redistribution caused by the accelerated aging procedure strongly differs from that obtained after aging under realistic stack operation (here over 1700 h) of a fuel cell in a pallet transporter. For the tomographic investigations samples were taken out from a stack operation in aged membrane electrode assembly (MEA) and were analyzed ex-situ. It was shown that the Ru redistribution can be attributed to mass transport processes (CO{sub 2} and H{sub 2}O) in the gas diffusion layer (GDL). Other high energy resolved measurements showed that the strength of the oxidation of ruthenium and platinum depends on the spatial distribution of the ruthenium. Last mentioned - also for the platinum catalyst - could be given quantitatively by means of this newly developed method. In the second part of this work high temperature polymer electrolyte fuel cells (HT-PEFC) were investigated. No liquid

  15. Neck x-ray

    Science.gov (United States)

    X-ray - neck; Cervical spine x-ray; Lateral neck x-ray ... There is low radiation exposure. X-rays are monitored so that the lowest amount of radiation is used to produce the image. Pregnant women and ...

  16. Analysis by synchrotron X-ray radiography of convection effects on the dynamic evolution of the solid-liquid interface and on solute distribution during the initial transient of solidification

    Energy Technology Data Exchange (ETDEWEB)

    Bogno, A., E-mail: abdoul-aziz.bogno@im2np.fr [Aix Marseille Universite, Campus Saint-Jerome, Case 142, 13397 Marseille Cedex 20 (France); CNRS, UMR 6242, Campus Saint-Jerome, Case 142, 13397 Marseille Cedex 20 (France); Nguyen-Thi, H. [Aix Marseille Universite, Campus Saint-Jerome, Case 142, 13397 Marseille Cedex 20 (France); CNRS, UMR 6242, Campus Saint-Jerome, Case 142, 13397 Marseille Cedex 20 (France); Buffet, A. [ESRF, Avenue des Martyrs, BP 220, 38048 Grenoble Cedex (France); Reinhart, G.; Billia, B.; Mangelinck-Noel, N.; Bergeon, N. [Aix Marseille Universite, Campus Saint-Jerome, Case 142, 13397 Marseille Cedex 20 (France); CNRS, UMR 6242, Campus Saint-Jerome, Case 142, 13397 Marseille Cedex 20 (France); Baruchel, J. [ESRF, Avenue des Martyrs, BP 220, 38048 Grenoble Cedex (France); Schenk, T. [LPM - ENSMN, Parc de Saurupt, 54042 Nancy Cedex (France)

    2011-06-15

    In situ monitoring of the initial transient of directional solidification was carried out by means of synchrotron X-ray radiography. Experiments with Al-4 wt.% Cu alloy samples were performed on beamline ID19 of the European Synchrotron Radiation Facility (ESRF) in a dedicated Bridgman-type furnace. X-ray radiography enabled a detailed analysis of the evolution over time of the solid-liquid interface macroscopic shape in interaction with convection in the melt. Lateral solute segregation induced by fluid flow resulted in a significant deformation of the solid-liquid interface. The time-dependent velocity of the solidification front was determined at different abscissa values along the curved interface during the solidification process, from the growth phase with a smooth interface to the onset of morphological instability. Further, using a novel quantitative image analysis technique we were able to measure longitudinal solute profiles in the melt during the initial transient. Solutal length was then deduced as well as concentration in the melt, both at the interface and far away from it. The influence of convection on growth velocity and the characteristic parameters of the solute boundary layer are discussed, and a comparison with the Warren and Langer model is also presented.

  17. MiniMAX: miniature, mobile, agile, x-ray system

    Science.gov (United States)

    Watson, Scott A.; Cunningham, Gwynneth; Gonzales, Samuel

    2012-06-01

    We present a unique, lightweight, compact, low-cost, x-ray imager: MiniMAX (Miniature, Mobile, Agile, X-ray). This system, which exploits the best aspects of Computed Radiography (CR) and Digital Radiography (DR) technology, weighs less than 6lbs, fits into a 6" diameter x 16" long carbon-fiber tube, and is constructed almost entirely from offthe- shelf components. MiniMAX is suitable for use in weld inspection, archaeology, homeland security, and veterinary medicine. While quantum limited for MeV radiography, the quantum-efficiency is too low for routine medical use. Formats include: 4"x6", 8"x12", or 16"x24" and can be readily displayed on the camera back, using a pocket projector, or on a tablet computer. In contrast to a conventional, flying-spot scanner, MiniMAX records a photostimulated image from the entire phosphor at once using a bright, red LED flash filtered through an extremely efficient (OD>9) dichroic filter.

  18. EFFECTS OF X-RAY BEAM ANGLE AND GEOMETRIC DISTORTION ON WIDTH OF EQUINE THORACOLUMBAR INTERSPINOUS SPACES USING RADIOGRAPHY AND COMPUTED TOMOGRAPHY

    DEFF Research Database (Denmark)

    Djernaes, Julie D.; Nielsen, Jon V.; Berg, Lise C.

    2017-01-01

    study was to determine whether X-ray beam angle has an effect on apparent widths of interspinous spaces. Thoracolumbar spine specimens were collected from six equine cadavers and left-right lateral radiographs and sagittal and dorsal reconstructed computed tomographic (CT) images were acquired...

  19. Experimental comparison of various techniques for spot size measurement of high-energy x-ray source

    CERN Document Server

    Wang, Yi; Chen, Nan; Cheng, Jinming; Li, Chenggang; Dai, Wenhua; Li, Hong; Long, Quanhong; Shi, Jinshui; Deng, Jianjun

    2015-01-01

    In the experiment of flash-radiography, the quality of acquired image strongly depends on the focal size of the x-ray source spot. A variety of techniques based on imaging of pinhole, slit and rollbar are adopted to measure the focal spot size of the Dragon-I linear induction accelerator. The image of pinhole provides a two-dimensional distribution of the x-ray spot, while those of slit and rollbar give a line-spread distribution and an edge-spread distribution, respectively. The spot size characterized by full-width at half-maximum and that characterized by the LANL definition are calculated for comparison.

  20. 基于光导开关的重复频率闪光X光机%Repetitive rate flash X-ray generator with photo conductive semiconductor switches

    Institute of Scientific and Technical Information of China (English)

    马勋; 袁建强; 刘宏伟; 王凌云; 姜苹; 李洪涛

    2016-01-01

    A repetitive rate flash X-ray generator was developed recently to meet the demands in scientific research and in-dustrial area.A repetitive pulsed power supply was fabricated with GaAs photo conductive semiconductor switches and stacked Blumlein pulse forming networks to drive industrial X-ray diode,and a novel X-ray diode was proposed with spoked metal ceramic flashover cathode.The results show that 2 pulse burst X rays were generated under 1 kHz frame rate with novel cathode,and the two power pulses of diode and X-ray signals were identical.%采用砷化镓光导开关和Blumlein 型脉冲形成网络以级联的拓扑形式构建平顶输出功率源,驱动工业 X 光二极管产生 X 射线。提出了一种轮辐状金属-陶瓷沿面阴极,并与普通金属阴极工业 X 光二极管重复频率实验结果进行比较。研究表明:受限于阴极重复频率下的电流发射能力,普通金属阴极工业 X 光二极管难以实现1 kHz 重复频率,采用新型阴极二极管实现了1 kHz 重复频率2猝发脉冲 X 光输出,这两个脉冲的二极管功率、X 射线信号基本一致。

  1. Phosphor Scanner For Imaging X-Ray Diffraction

    Science.gov (United States)

    Carter, Daniel C.; Hecht, Diana L.; Witherow, William K.

    1992-01-01

    Improved optoelectronic scanning apparatus generates digitized image of x-ray image recorded in phosphor. Scanning fiber-optic probe supplies laser light stimulating luminescence in areas of phosphor exposed to x rays. Luminescence passes through probe and fiber to integrating sphere and photomultiplier. Sensitivity and resolution exceed previously available scanners. Intended for use in x-ray crystallography, medical radiography, and molecular biology.

  2. Cross-sectional void fraction distribution measurements in a vertical annulus two-phase flow by high speed X-ray computed tomography and real-time neutron radiography techniques

    Energy Technology Data Exchange (ETDEWEB)

    Harvel, G.D. [McMaster Univ., Ontario (Canada)]|[Combustion and Heat Transfer Lab., Takasago (Japan); Hori, K.; Kawanishi, K. [Combustion and Heat Transfer Lab., Takasago (Japan)] [and others

    1995-09-01

    A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,{theta}) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.

  3. Chest X Ray?

    Science.gov (United States)

    ... this page from the NHLBI on Twitter. Chest X Ray A chest x ray is a fast and painless imaging test ... tissue scarring, called fibrosis. Doctors may use chest x rays to see how well certain treatments are ...

  4. X-Rays

    Science.gov (United States)

    X-rays are a type of radiation called electromagnetic waves. X-ray imaging creates pictures of the inside of ... different amounts of radiation. Calcium in bones absorbs x-rays the most, so bones look white. Fat ...

  5. Medical X-Rays

    Science.gov (United States)

    ... Benefits The discovery of X-rays and the invention of CT represented major advances in medicine. X- ... in X-ray and CT Examinations — X-ray definition, dose measurement, safety precautions, risk, and consideration with ...

  6. The Image Quality of a Digital Chest X-Ray Radiography System: Comparison of Quantitative Image Quality Analysis and Radiologists' Visual Scoring

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Ji Ho [Dept. of Radiology Oncology, Yongsan Hospital, Pusan National University College of Medicine, Yongsan (Korea, Republic of); Chung, Myung Jin [Dept. of Radiology, Samsung Medical Center, Seoul (Korea, Republic of); Park, Darl; Kim, Won Taek; Kim, Yong Ho; Ki, Yong Kan; Kim, DFong Hyun; Lee, Ju Hee; Kim, Dong Won [Dept. of Radiology Oncology, Yongsan Hospital, Pusan National University College of Medicine, Yongsan (Korea, Republic of); Jeon, Ho Sang [Reserach Institue for Convergence of Biomedical Science and Technology, Yongsan Hospital, Pusan National University College of Medicine, Yongsan (Korea, Republic of)

    2011-11-15

    To evaluate the performance of imaging devices, which should be periodically monitored to maintain high quality images to the radiologists. Additionally, this evaluation may prevent patients from radiation over-exposure. The most suitable engineering standard for imaging performance evaluation of digital X-ray thoracic images was determined. IEC 62220-1 standards were used to evaluate the performance of the images. In succession, the visibilities of overall image, pneumothorax, and humerus head in anthropomorphic thoracic phantom images were used to evaluate the image qualities by radiologists. The rank correlation coefficient (p) of visual scoring by radiologists with system spatial resolution is not meaningful (p-value, p = 0.295), but is significant with image noise (p-value, p -0.9267). Finally, the noise equivalent quanta (NEQ) presents a high rank correlation for visual scoring of radiologists (p-value, p = 0.9320). Image quality evaluation of radiologists were mainly affected by imaging noise. Hence, the engineered standard for evaluating image noise is the most important index to effectively monitor the performance of X-ray images. Additionally, the NEQ can be used to evaluate the performance of radiographic systems, because it theoretically corresponds to the synthetic image quality of systems.

  7. Peak potential meter applied to X-ray tubes in mammal radiography systems; Medidor do potencial de pico aplicado em tubos de raio-X de sistemas mamograficos

    Energy Technology Data Exchange (ETDEWEB)

    Schiabel, Homero; Frere, Annie F. [Sao Paulo Univ., Sao Carlos, SP (Brazil). Escola de Engenharia; Andreeta, Jose P. [Sao Paulo Univ., Sao Carlos, SP (Brazil). Inst. de Fisica e Quimica

    1989-12-31

    It is of a great importance to identify accurately the real peak potential (or simply, KVp) applied to a X-ray tube purposed to medical diagnosis, since it defines the beam energetic quality in terms of photons penetration power. Mainly in mammographic systems. it is of fundamental relevance the KVp accurate measurement because the soft tissues involved in this kind of examination provides different absorption - and, hence, clear contrast on mammographic film - just in a very restrict energetic range. Thus a device to measure KVp with adequate accuracy in mammographic units, using the basic principles of scintillation detection, was developed. This system is therefore composed of a NaI(Tl) crystal which is a X-ray sensor - replacing radiographic films which usually are a source of errors in these measurements - , a photo multiplier tube and changed into amplified electric pulses. Finally the electronic circuit, after adequate pulses treatment, shows instantaneously the actual KVp value in the test on displays. (author) 2 refs.

  8. Influence of x-ray energy spectrum, contrasting detail and detector on the signal-to-noise ratio (SNR) and detective quantum efficiency (DQE) in projection radiography

    Energy Technology Data Exchange (ETDEWEB)

    Sandborg, Michael; Carlsson, G.A. (Linkoeping Univ. (Sweden). Dept. of Radiation Physics)

    1992-06-01

    A lower limit to patient irradiation in diagnostic radiology is set by the fundamental stochastics of the energy imparted to the image receptor (quantum noise). Image quality is investigated here and expressed in terms of the signal-to-noise ratio due to quantum noise. The Monte Carlo method is used to calculate signal-to-noise ratios (SNR{sub {Delta}S}) and detective quantum efficiencies (DQE{sub {Delta}S}) in imaging thin contrasting details of air, fat, bone and iodine within a water phantom using x-ray spectra (40-140 kV) and detectors of CsI, BaFCl and Gd{sub 2}O{sub 2}S. The atomic composition of the contrasting detail influences considerably the values of SNR{sub {Delta}S} due to the different modulations of the energy spectra of primary photons passing beside and through the contrasting detail. (author).

  9. X-ray digital industrial radiography (DIR) for local liquid velocity (VLL) measurement in trickle bed reactors (TBRs): Validation of the technique

    Science.gov (United States)

    Mohd Salleh, Khairul Anuar; Rahman, Mohd Fitri Abdul; Lee, Hyoung Koo; Al Dahhan, Muthanna H.

    2014-06-01

    Local liquid velocity measurements in Trickle Bed Reactors (TBRs) are one of the essential components in its hydrodynamic studies. These measurements are used to effectively determine a reactor's operating condition. This study was conducted to validate a newly developed technique that combines Digital Industrial Radiography (DIR) with Particle Tracking Velocimetry (PTV) to measure the Local Liquid Velocity (VLL) inside TBRs. Three millimeter-sized Expanded Polystyrene (EPS) beads were used as packing material. Three validation procedures were designed to test the newly developed technique. All procedures and statistical approaches provided strong evidence that the technique can be used to measure the VLL within TBRs.

  10. Particle-In-Cell Simulations of the Electron Beam Source for X-Ray Radiography Generated by the Rod-Pinch Diode in the Cygnus Experiment

    Science.gov (United States)

    Yin, Lin; Kwan, Thomas; Devolder, Barbara; Berninger, Mike; Bowers, Kevin; Smith, John

    2003-10-01

    The Cygnus experiment [Smith et al., AIP Conference Proceedings, 650, 135, 2002] is in operation at Los Alamos National Laboratory to support the Sub-Critical Experiments Program at the Nevada Test Site. In the Cygnus design, a rod-pinch diode is used to produce a low-energy (up to ˜ 2.25 MeV) radiographic electron source at the tip of a needle anode rod that extends through an annular cathode. As the electrons deposit their energies on the high-Z anode tip, bremsstrahlung photons are produced and are used to generate radiographs of an object. In this work we use the two-dimensional particle-in-cell code MERLIN to examine the diode physics and the dynamics of the rod-pinch electron source which is used in integrated X-ray radiographic chain model calculations [Kwan et al., Comp. Phys. Comm., 142, 263, 2001]. TEM waves are launched at one simulation boundary to set up the voltage required for the electron emission. Electron and ion trajectories are followed self-consistently in the electromagnetic fields as the electron beam impinges at the tip of the anode rod. The MERLIN simulation results of the electron endpoint energy and the diode voltage/current are consistent with the peak values obtained from Cygnus shots. The diode impedance response to the experimental parameters currently used in the Cygnus shots will be discussed.

  11. Progress in electron-multiplying CCD (EMCCD) based high-resolution high-sensitivity x-ray detector for fluoroscopy and radiography

    Science.gov (United States)

    Kuhls, Andrew T.; Yadava, Girijesh; Patel, Vikas; Bednarek, Daniel R.; Rudin, Stephen

    2007-03-01

    A new high-resolution, high-sensitivity, low-noise x-ray detector based on EMCCDs has been developed. The EMCCD detector module consists of a 1kx1k, 8μm pixel EMCCD camera coupled to a CsI(Tl) scintillating phosphor via a fiber optic taper (FOT). Multiple modules can be used to provide the desired field-of-view (FOV). The detector is capable of acquisitions over 30fps. The EMCCD's variable gain of up to 2000x for the pixel signal enables high sensitivity for fluoroscopic applications. With a 3:1 FOT, the detector can operate with a 144μm effective pixel size, comparable to current flat-panel detectors. Higher resolutions of 96 and 48μm pixel size can also be achieved with various binning modes. The detector MTFs and DQEs were calculated using a linear-systems analysis. The zero frequency DQE was calculated to be 59% at 74 kVp. The DQE for the 144μm pixel size was shown to exhibit quantum-noise limited behavior down to ~0.1μR using a conservative 30x gain. At this low exposure, gains above 30x showed limited improvements in DQE suggesting such increased gains may not be necessary. For operation down to 48µm pixel sizes, the detector instrumentation noise equivalent exposure (INEE), defined as the exposure where the instrumentation noise equals the quantum-noise, was flat-panel detectors for applications such as fluoroscopy and angiography requiring high frame rates, resolution, dynamic range and sensitivity while maintaining essentially no lag and very low INEE. Initial images from a prototype detector are also presented.

  12. Research on the diagnostic significance of supraspinatus export slice X-ray radiography in rotator cuff injury%冈上肌出口位X线摄片在肩袖损伤诊断中的意义

    Institute of Scientific and Technical Information of China (English)

    梁红; 钟易

    2013-01-01

    Objective:To explore the application value of supraspinatus export slice X-ray radiography in rotator cuff injury.Methods:To conduct retrospective analysis on imaging data of 21 cases with rotator cuff injury diagnosed by MRI.Before the MRI examination,6 patients received the affected side shoulder X-ray films and 15 patients did the affected side supraspinatus export slice X-ray films.The results between the two groups were analyzed.Results:Twenty-one patients were diagnosed in rotator cuff injury by MRI,15 patients were in acromion-humeral head spacing stenosis varying degrees.The result from 3 cases of patients A-H spacing is 5.1~6.9mm.6 cases of patients A-H spacing were7.0~7.9mm,and 6 cases of patients A-H spacing is 8.0~9.0mm.No signs of bone lesions.Six cases of patients of shoulder anteroposterior X-ray normal.Conclusion:Supraspinatus export slice X-ray film can offered help to constitute the therapy plan of clinical treatment.%目的:探讨冈上肌出口位X线摄片在肩袖损伤影像学诊断中的应用价值.方法:回顾性分析21例经MRI确诊肩袖损伤的患者的相关影像学资料,15例患者在做MRI检查前摄取了侧肩关节冈上肌出口位X线片,6例患者仅摄取了侧肩关节X线正位片,将其影像学诊断结果进行对比.结果:21例患者MRI检查全部提示为肩袖损伤.15例患者摄取侧肩关节冈上肌出口位X线片测得肩峰-肱骨头(A-H)间距不同程度狭窄,其中3例患者A-H间距≤5.1~6.9mm、6例患者A-H间距≤7.0~7.9 mm、6例患者A-H间距≤8.0~9.0mm,所见构成骨未见明确骨质病变征象;6例患者仅摄取侧肩关节正位的X线片诊断均为阴性.结论:冈上肌出口位X线摄片能清晰测量A-H间距,提示肩袖损伤的存在,对患者的下一步检查及制定治疗方案具有重要的临床意义.

  13. Studies of solid propellant combustion with pulsed radiography

    Science.gov (United States)

    Godai, T.; Tanemura, T.; Fujiwara, T.; Shimizu, M.

    1987-01-01

    Pulsed radiography was applied to observe solid propellant surface regression during rocket motor operation. Using a 150 KV flash X-ray system manufactured by the Field Emission Corporation and two kinds of film suppliers, images of the propellant surface of a 5 cm diameter end burning rocket motor were recorded on film. The repetition frame rate of 8 pulses per second and the pulse train length of 10 pulses are limited by the capability of the power supply and the heat build up within the X-ray tube, respectively. The experiment demonstrated the effectiveness of pulsed radiography for observing solid propellant surface regression. Measuring the position of burning surface images on film with a microdensitometer, quasi-instantaneous burning rate as a function of pressure and the variation of characteristic velocity with pressure and gas stay time were obtained. Other research items to which pulsed radiography can be applied are also suggested.

  14. LOBSTER - New Space X-Ray telescopes

    Energy Technology Data Exchange (ETDEWEB)

    Hudec, R. [Astronomical Institute, Academy of Sciences of the Czech Republic, CZ-251 65 Ondrejov (Czech Republic); Pina, L. [Faculty of Nuclear Science, Czech Technical University, Prague (Czech Republic); Simon, V. [Astronomical Institute, Academy of Sciences of the Czech Republic, CZ-251 65 Ondrejov (Czech Republic); Sveda, L. [Faculty of Nuclear Science, Czech Technical University, Prague (Czech Republic); Inneman, A.; Semencova, V. [Center for Advanced X-ray Technologies, Reflex, Prague (Czech Republic); Skulinova, M. [Astronomical Institute, Academy of Sciences of the Czech Republic, CZ-251 65 Ondrejov (Czech Republic)

    2007-04-15

    We discuss the technological and scientific aspects of fully innovative very wide-field X-ray telescopes with high sensitivity. The prototypes of Lobster telescopes designed, developed and tested are very promising, allowing the proposals for space projects with very wide-field Lobster Eye X-ray optics to be considered for the first time. The novel telescopes will monitor the sky with unprecedented sensitivity and angular resolution of order of 1 arcmin. They are expected to contribute essentially to study of various astrophysical objects such as AGN, SNe, Gamma-ray bursts (GRBs), X-ray flashes (XRFs), galactic binary sources, stars, CVs, X-ray novae, various transient sources, etc. For example, the Lobster optics based X-ray All Sky Monitor is capable to detect around 20 GRBs and 8 XRFs yearly and this will surely significantly contribute to the related science.

  15. Extremity x-ray

    Science.gov (United States)

    ... degenerative) Bone tumor Broken bone (fracture) Dislocated bone Osteomyelitis (infection) Arthritis Other conditions for which the test ... Bone tumor Bone x-ray Broken bone Clubfoot Osteomyelitis X-ray Review Date 7/3/2016 Updated ...

  16. Abdominal x-ray

    Science.gov (United States)

    ... are, or may be, pregnant. Alternative Names Abdominal film; X-ray - abdomen; Flat plate; KUB x-ray ... Assistant Studies, Department of Family Medicine, UW Medicine, School of Medicine, University of Washington, Seattle, WA. Also ...

  17. Experimental comparison of various techniques for spot size measurement of high-energy X-ray

    Science.gov (United States)

    Wang, Yi; Li, Qin; Chen, Nan; Cheng, Jin-Ming; Li, Cheng-Gang; Li, Hong; Long, Quan-Hong; Shi, Jin-Shui; Deng, Jian-Jun

    2016-08-01

    In flash-radiography experiments, the quality of the acquired image strongly depends on the focal size of the X-ray source spot. A variety of techniques based on imaging of the pinhole, the slit and the rollbar are adopted to measure the focal spot size of the Dragon-I linear induction accelerator. The image of the pinhole provides a two-dimensional distribution of the X-ray spot, while those of the slit and the rollbar give a line-spread distribution and an edge-spread distribution, respectively. The spot size characterized by the full-width at half-maximum and that characterized by the LANL definition are calculated for comparison.

  18. Metal alloys, matrix inclusions and manufacturing techniques of Moinhos de Golas collection (North Portugal): a study by micro-EDXRF, SEM-EDS, optical microscopy and X-ray radiography

    Science.gov (United States)

    Loureiro, Joana; Figueiredo, Elin; Silva, Rui J. C.; Araújo, M. Fátima; Fonte, João; Bettencourt, Ana M. S.

    2016-09-01

    A collection of 35 metallic artefacts comprising various typologies, some of which can be attributed to the Bronze Age and others to later periods, were studied to provide detailed information on elemental composition, manufacturing techniques and preservation state. Elemental analysis by micro-EDXRF and SEM-EDS was performed to investigate the use of different alloys and to study the presence of microstructural heterogeneities, as inclusions. X-ray radiography, optical microscopy and SEM-EDS were used to investigate manufacturing techniques and degradation features. Results showed that most of the artefacts were produced in a binary bronze alloy (Cu-Sn) with 10-15 wt% Sn and a low concentration of impurities. Other artefacts were produced in copper or in brass, the latest with varying contents of Zn, Sn and Pb. A variety of inclusions in the metal matrices were also found, some related to specific types of alloys, as (Cu-Ni)S2 in coppers, or ZnS in brasses. Microstructural observations revealed that the majority of the artefacts were subjected to cycles of thermomechanical processing after casting, being evident that among some artefacts different parts were subjected to distinct treatments. The radiographic images revealed structural heterogeneities related to local corrosion processes and fissures that seem to have developed in wear-tension zones, as in the handle of some daggers. Radiographic images were also useful to detect the use of different materials in one particular brass artefact, revealing the presence of a possible Cu-Sn solder.

  19. X-Ray Supernovae

    CERN Document Server

    Immler, S; Immler, Stefan; Lewin, Walter H.G.

    2002-01-01

    We present a review of X-ray observations of supernovae (SNe). By observing the (~0.1--100 keV) X-ray emission from young SNe, physical key parameters such as the circumstellar matter (CSM) density, mass-loss rate of the progenitor and temperature of the outgoing and reverse shock can be derived as a function of time. Despite intensive search over the last ~25 years, only 15 SNe have been detected in X-rays. We review the individual X-ray observations of these SNe and discuss their implications as to our understanding of the physical processes giving rise to the X-ray emission.

  20. Increasing mobile radiography productivity.

    Science.gov (United States)

    Wong, Edward; Lung, Ngan Tsz; Ng, Kris; Jeor, Patrick

    2013-01-01

    Mobile radiography using computed radiography (CR) cassettes is a common equipment combination with a workflow bottleneck limited by location of CR readers. Advent of direct digital radiography (DDR) mobile x-ray machines removes this limitation by immediate image review and quality control. Through the use of key performance indicators (KPIs), the increase in efficiency can be quantified.

  1. Demonstration of X-ray talbot interferometry

    CERN Document Server

    Momose, A; Kawamoto, S; Hamaishi, Y; Takai, K; Suzuki, Y

    2003-01-01

    First Talbot interferometry in the hard X-ray region was demonstrated using a pair of transmission gratings made by forming gold stripes on glass plates. By aligning the gratings on the optical axis of X-rays with a separation that caused the Talbot effect by the first grating, moire fringes were produced inclining one grating slightly against the other around the optical axis. A phase object placed in front of the first grating was detected by moire-fringe bending. Using the technique of phase-shifting interferometry, the differential phase corresponding to the phase object could also be measured. This result suggests that X-ray Talbot interferometry is a novel and simple method for phase-sensitive X-ray radiography. (author)

  2. X-ray findings in the skeleton of the hand to prove renal osteopathy. Soft ray immersions radiography versus standard procedures; Roentgendiagnostik der renalen Osteopathie am Handskelett. Weichstrahl-Immersions-Radiographie kontra Standardtechnik

    Energy Technology Data Exchange (ETDEWEB)

    Pollack, T. [Radiologische Klinik, Krankenhaus Dresden-Friedrichstadt, Staedtisches Klinikum (Germany); Friedberg, R. [Radiologische Klinik, Krankenhaus Dresden-Friedrichstadt, Staedtisches Klinikum (Germany); Heinicke, H.J. [1. Medizinische Klinik, Krankenhaus Dresden-Friedrichstadt, Staedtisches Klinikum (Germany)

    1994-11-01

    In examinations of the hand skeleton, findings typical of renal osteopathy are much more readily revealed by soft ray immersions radiography than by images obtained using conventional techniques. In combination with microradioscopy the method is highly suitable for the primary diagnosis and follow-up of renal osteopathy. The information provided eliminates the need for examinations of other skeletal sections and thus justifies the slightly increased dose requirements. The fact that unchanged parathormone can be determined simultaneously adds to the sensitivity of this non-invasive technique. Histological assessments of the skeleton can, however, not always be avoided. (orig.) [Deutsch] Die Untersuchung des Handskeletts mit Hilfe der Weichstrahl-Immersions-Radiographie (WIR) ist fuer typische Befunde der renalen Osteopathie wesentlich sensitiver als die Aufnahmen in Standardtechnik. In Kombination mit der Mikroradioskopie ist sie fuer die roentgenologische Basisdiagnostik und Verlaufskontrolle der renalen Osteopathie sehr gut geeignet. Der Informationsgewinn und die Moeglichkeit der Einsparung von Roentgenuntersuchungen anderer Skelettabschnitte rechtfertigt den etwas hoeheren Dosisbedarf der WIR. Die gleichzeitige Bestimmung des intakten Parathormons erhoeht die Sensitivitaet der nichtinvasiven Diagnostik. Dennoch laesst sich auf eine Knochenhistologie nicht in jedem Fall verzichten. (orig.)

  3. X-ray holographic microscopy with zone plates applied to biological samples in the water window using 3rd harmonic radiation from the free-electron laser FLASH.

    Science.gov (United States)

    Gorniak, T; Heine, R; Mancuso, A P; Staier, F; Christophis, C; Pettitt, M E; Sakdinawat, A; Treusch, R; Guerassimova, N; Feldhaus, J; Gutt, C; Grübel, G; Eisebitt, S; Beyer, A; Gölzhäuser, A; Weckert, E; Grunze, M; Vartanyants, I A; Rosenhahn, A

    2011-06-06

    The imaging of hydrated biological samples - especially in the energy window of 284-540 eV, where water does not obscure the signal of soft organic matter and biologically relevant elements - is of tremendous interest for life sciences. Free-electron lasers can provide highly intense and coherent pulses, which allow single pulse imaging to overcome resolution limits set by radiation damage. One current challenge is to match both the desired energy and the intensity of the light source. We present the first images of dehydrated biological material acquired with 3rd harmonic radiation from FLASH by digital in-line zone plate holography as one step towards the vision of imaging hydrated biological material with photons in the water window. We also demonstrate the first application of ultrathin molecular sheets as suitable substrates for future free-electron laser experiments with biological samples in the form of a rat fibroblast cell and marine biofouling bacteria Cobetia marina.

  4. X-Ray Polarimetry

    CERN Document Server

    Kaaret, Philip

    2014-01-01

    We review the basic principles of X-ray polarimetry and current detector technologies based on the photoelectric effect, Bragg reflection, and Compton scattering. Recent technological advances in high-spatial-resolution gas-filled X-ray detectors have enabled efficient polarimeters exploiting the photoelectric effect that hold great scientific promise for X-ray polarimetry in the 2-10 keV band. Advances in the fabrication of multilayer optics have made feasible the construction of broad-band soft X-ray polarimeters based on Bragg reflection. Developments in scintillator and solid-state hard X-ray detectors facilitate construction of both modular, large area Compton scattering polarimeters and compact devices suitable for use with focusing X-ray telescopes.

  5. Novel X-ray telescopes for wide-field X-ray monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Hudec, R. [Academy of science of Czech Republic, Ondrejov (Czech Republic); Inneman, A. [Centre for advanced X-ray technologies Reflex sro, Prague (Czech Republic); Pina, L.; Sveda, L. [Czech Technical Univ., Prague (Czech Republic). Faculty of Nuclear Science

    2005-07-15

    We report on fully innovative very wide-field of view X-ray telescopes with high sensitivity as well as large field of view. The prototypes are very promising, allowing the proposals for space projects with very wide-field Lobster-eye X-ray optics to be considered. The novel telescopes will monitor the sky with unprecedented sensitivity and angular resolution of order of 1 arcmin. They are expected to contribute essentially to study and to understand various astrophysical objects such as AGN, SNe, Gamma-ray bursts (GRBs), X-ray flashes (XRFs), galactic binary sources, stars, CVs, X-ray novae, various transient sources, etc. The Lobster optics based X-ray All Sky Monitor is capable to detect around 20 GRBs and 8 XRFs yearly and this will surely significantly contribute to the related science.

  6. X-Ray

    Science.gov (United States)

    ... You may be allowed to remain with your child during the test. If you remain in the room during the X-ray exposure, you'll likely be asked to wear a lead apron to shield you from unnecessary exposure. After the X-ray ...

  7. Dental x-rays

    Science.gov (United States)

    ... X-rays are a form of high energy electromagnetic radiation. The x-rays penetrate the body to form ... for detecting cavities, unless the decay is very advanced and deep. Many ... The amount of radiation given off during the procedure is less than ...

  8. X-Ray Surveys

    CERN Document Server

    Giommi, P; Perri, M

    1998-01-01

    A review of recent developments in the field of X-ray surveys, especially in the hard (2-10 and 5-10 keV) bands, is given. A new detailed comparison between the measurements in the hard band and extrapolations from ROSAT counts, that takes into proper account the observed distribution of spectral slopes, is presented. Direct comparisons between deep ROSAT and BeppoSAX images show that most hard X-ray sources are also detected at soft X-ray energies. This may indicate that heavily cutoff sources, that should not be detectable in the ROSAT band but are expected in large numbers from unified AGN schemes, are in fact detected because of the emerging of either non-nuclear components, or of reflected, or partially transmitted nuclear X-rays. These soft components may complicate the estimation of the soft X-ray luminosity function and cosmological evolution of AGN.

  9. X-ray Polarimetry

    Science.gov (United States)

    Kallman, T.

    In spite of the recent advances in X-ray instrumentation, polarimetry remains an area which has been virtually unexplored in the last 20 years. The scientific motivation to study polarization has increased during this time: emission models designed to repro- duce X-ray spectra can be tested using polarization, and polarization detected in other wavelength bands makes clear predictions as to the X-ray polarization. Polarization remains the only way to infer geometrical properties of sources which are too small to be spatially resolved. At the same time, there has been recent progress in instrumen- tation which is likely to allow searches for X-ray polarization at levels significantly below what was possible for early detectors. In this talk I will review the history of X-ray polarimetry, discuss some experimental techniques and the scientific problems which can be addressed by future experiments.

  10. X-ray crystallography

    Science.gov (United States)

    2001-01-01

    X-rays diffracted from a well-ordered protein crystal create sharp patterns of scattered light on film. A computer can use these patterns to generate a model of a protein molecule. To analyze the selected crystal, an X-ray crystallographer shines X-rays through the crystal. Unlike a single dental X-ray, which produces a shadow image of a tooth, these X-rays have to be taken many times from different angles to produce a pattern from the scattered light, a map of the intensity of the X-rays after they diffract through the crystal. The X-rays bounce off the electron clouds that form the outer structure of each atom. A flawed crystal will yield a blurry pattern; a well-ordered protein crystal yields a series of sharp diffraction patterns. From these patterns, researchers build an electron density map. With powerful computers and a lot of calculations, scientists can use the electron density patterns to determine the structure of the protein and make a computer-generated model of the structure. The models let researchers improve their understanding of how the protein functions. They also allow scientists to look for receptor sites and active areas that control a protein's function and role in the progress of diseases. From there, pharmaceutical researchers can design molecules that fit the active site, much like a key and lock, so that the protein is locked without affecting the rest of the body. This is called structure-based drug design.

  11. X-ray lasers

    CERN Document Server

    Elton, Raymond C

    2012-01-01

    The first in its field, this book is both an introduction to x-ray lasers and a how-to guide for specialists. It provides new entrants and others interested in the field with a comprehensive overview and describes useful examples of analysis and experiments as background and guidance for researchers undertaking new laser designs. In one succinct volume, X-Ray Lasers collects the knowledge and experience gained in two decades of x-ray laser development and conveys the exciting challenges and possibilities still to come._Add on for longer version of blurb_M>The reader is first introduced

  12. The X-ray imager on AXO

    Science.gov (United States)

    Budtz-Jørgensen, C.; Kuvvetli, I.; Westergaard, N. J.; Jonasson, P.; Reglero, V.; Eyles, C.

    2001-02-01

    DSRI has initiated a development program of CZT X-ray and gamma-ray detectors employing strip readout techniques. A dramatic improvement of the energy response was found operating the detectors as the so-called drift detectors. For the electronic readout, modern ASIC chips were investigated. Modular design and the low-power electronics will make large area detectors using the drift strip method feasible. The performance of a prototype CZT system will be presented and discussed. One such detector system has been proposed for future space missions: the X-Ray Imager (XRI) on the Atmospheric X-ray Observatory (AXO), which is a mission proposed to the Danish Small Satellite Program and is dedicated to observations of X-ray generating processes in the Earth's atmosphere. Of special interest will be simultaneous optical and X-ray observations of sprites that are flashes appearing directly above an active thunderstorm system. Additional objective is a detailed mapping of the auroral X-ray and optical emission. XRI comprises a coded mask and a 20×40 cm 2 CZT detector array covering an energy range from 5 to 200 keV.

  13. Associated factors of atrophic gastritis diagnosed by double-contrast upper gastrointestinal barium X-ray radiography: a cross-sectional study analyzing 6,901 healthy subjects in Japan.

    Directory of Open Access Journals (Sweden)

    Nobutake Yamamichi

    Full Text Available Double-contrast upper gastrointestinal barium X-ray radiography (UGI-XR is one of the most widely conducted gastric cancer screening methods. It has been executed to find gastric cancer, but has not been usually executed to detect premalignant atrophic mucosa of stomach. To understand the meaning of UGI-XR-based atrophic gastritis, we analyzed its association with several causative factors including Helicobacter pylori (HP infection.We evaluated 6,901 healthy adults in Japan. UGI-XR-based atrophic gastritis was diagnosed based on the irregular shape of areae gastricae and its expansion in the stomach.Of the 6,433 subjects with no history of HP eradication and free from gastric acid suppressants, 1,936 were diagnosed as UGI-XR-based atrophic gastritis (mild: 234, moderate: 822, severe: 880. These were univariately associated with serum HP IgG and serum pepsinogen I/II ratio with statistical significance. The multiple logistic analysis calculating standardized coefficients (β and odds ratio (OR demonstrated that serum HP IgG (β = 1.499, OR = 4.48, current smoking (β = 0.526, OR = 1.69, age (β = 0.401, OR = 1.49, low serum pepsinogen I/II ratio (β = 0.339, OR = 1.40, and male gender (β = 0.306, OR = 1.36 showed significant positive association with UGI-XR-based atrophic gastritis whereas drinking and body mass index did not. Among the age/sex/smoking/drinking-matched 227 pairs derived from chronically HP-infected and successfully HP-eradicated subjects, UGI-XR-based atrophic gastritis was detected in 99.1% of the former but in only 59.5% of the latter subjects (p<0.0001. Contrastively, UGI-XR-based atrophic gastritis was detected in 13 of 14 HP-positive proton pump inhibitor users (92.9% and 33 of 34 HP-positive histamine H2-receptor antagonist users (97.1%, which are not significantly different from gastric acid suppressant-free subjects.The presence of UGI-XR-based atrophic gastritis is positively

  14. Associated Factors of Atrophic Gastritis Diagnosed by Double-Contrast Upper Gastrointestinal Barium X-Ray Radiography: A Cross-Sectional Study Analyzing 6,901 Healthy Subjects in Japan

    Science.gov (United States)

    Yamamichi, Nobutake; Hirano, Chigaya; Shimamoto, Takeshi; Minatsuki, Chihiro; Takahashi, Yu; Nakayama, Chiemi; Matsuda, Rie; Fujishiro, Mitsuhiro; Konno-Shimizu, Maki; Kato, Jun; Kodashima, Shinya; Ono, Satoshi; Niimi, Keiko; Mochizuki, Satoshi; Tsuji, Yosuke; Sakaguchi, Yoshiki; Asada-Hirayama, Itsuko; Takeuchi, Chihiro; Yakabi, Seiichi; Kakimoto, Hikaru; Wada, Ryoichi; Mitsushima, Toru; Ichinose, Masao; Koike, Kazuhiko

    2014-01-01

    Background Double-contrast upper gastrointestinal barium X-ray radiography (UGI-XR) is one of the most widely conducted gastric cancer screening methods. It has been executed to find gastric cancer, but has not been usually executed to detect premalignant atrophic mucosa of stomach. To understand the meaning of UGI-XR-based atrophic gastritis, we analyzed its association with several causative factors including Helicobacter pylori (HP) infection. Methods We evaluated 6,901 healthy adults in Japan. UGI-XR-based atrophic gastritis was diagnosed based on the irregular shape of areae gastricae and its expansion in the stomach. Results Of the 6,433 subjects with no history of HP eradication and free from gastric acid suppressants, 1,936 were diagnosed as UGI-XR-based atrophic gastritis (mild: 234, moderate: 822, severe: 880). These were univariately associated with serum HP IgG and serum pepsinogen I/II ratio with statistical significance. The multiple logistic analysis calculating standardized coefficients (β) and odds ratio (OR) demonstrated that serum HP IgG (β = 1.499, OR = 4.48), current smoking (β = 0.526, OR = 1.69), age (β = 0.401, OR = 1.49), low serum pepsinogen I/II ratio (β = 0.339, OR = 1.40), and male gender (β = 0.306, OR = 1.36) showed significant positive association with UGI-XR-based atrophic gastritis whereas drinking and body mass index did not. Among the age/sex/smoking/drinking-matched 227 pairs derived from chronically HP-infected and successfully HP-eradicated subjects, UGI-XR-based atrophic gastritis was detected in 99.1% of the former but in only 59.5% of the latter subjects (pgastritis was detected in 13 of 14 HP-positive proton pump inhibitor users (92.9%) and 33 of 34 HP-positive histamine H2-receptor antagonist users (97.1%), which are not significantly different from gastric acid suppressant-free subjects. Conclusions The presence of UGI-XR-based atrophic gastritis is positively associated with

  15. Bone x-ray

    Science.gov (United States)

    ... or broken bone Bone tumors Degenerative bone conditions Osteomyelitis (inflammation of the bone caused by an infection) ... Multiple myeloma Osgood-Schlatter disease Osteogenesis imperfecta Osteomalacia Osteomyelitis Paget disease of the bone Rickets X-ray ...

  16. Hand x-ray

    Science.gov (United States)

    ... include fractures, bone tumors , degenerative bone conditions, and osteomyelitis (inflammation of the bone caused by an infection). ... chap 46. Read More Bone tumor Broken bone Osteomyelitis X-ray Review Date 9/8/2014 Updated ...

  17. Pelvis x-ray

    Science.gov (United States)

    X-ray - pelvis ... Tumors Degenerative conditions of bones in the hips, pelvis, and upper legs ... hip joint Tumors of the bones of the pelvis Sacroiliitis (inflammation of the area where the sacrum ...

  18. Chest X-Ray

    Medline Plus

    Full Text Available ... and use a very small dose of ionizing radiation to produce pictures of the inside of the ... x-ray use a tiny dose of ionizing radiation, the benefit of an accurate diagnosis far outweighs ...

  19. Chest X-Ray

    Medline Plus

    Full Text Available ... Index A-Z Spotlight October is National Breast Cancer Awareness Month Recently posted: Medical Imaging Costs Magnetoencephalography ( ... of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray requires no special preparation. ...

  20. Chest X-Ray

    Medline Plus

    Full Text Available ... chest x-ray is used to evaluate the lungs, heart and chest wall and may be used ... diagnose and monitor treatment for a variety of lung conditions such as pneumonia, emphysema and cancer. A ...

  1. X-ray - skeleton

    Science.gov (United States)

    ... x-ray particles pass through the body. A computer or special film records the images. Structures that ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  2. X-Ray Diffraction.

    Science.gov (United States)

    Smith, D. K.; Smith, K. L.

    1980-01-01

    Reviews applications in research and analytical characterization of compounds and materials in the field of X-ray diffraction, emphasizing new developments in applications and instrumentation in both single crystal and powder diffraction. Cites 414 references. (CS)

  3. Chest X-Ray

    Medline Plus

    Full Text Available ... breath, persistent cough, fever, chest pain or injury. It may also be useful to help diagnose and ... have some concerns about chest x-rays. However, it’s important to consider the likelihood of benefit to ...

  4. X-Ray Diffraction.

    Science.gov (United States)

    Smith, D. K.; Smith, K. L.

    1980-01-01

    Reviews applications in research and analytical characterization of compounds and materials in the field of X-ray diffraction, emphasizing new developments in applications and instrumentation in both single crystal and powder diffraction. Cites 414 references. (CS)

  5. Chest X-Ray

    Medline Plus

    Full Text Available ... breath, persistent cough, fever, chest pain or injury. It may also be useful to help diagnose and ... have some concerns about chest x-rays. However, it’s important to consider the likelihood of benefit to ...

  6. Chest X-Ray

    Medline Plus

    Full Text Available ... CT Angiography Video: Myelography Video: CT of the Heart Video: Radioiodine I-131 Therapy Radiology and You ... x-ray is used to evaluate the lungs, heart and chest wall and may be used to ...

  7. Neutron Radiography

    Science.gov (United States)

    Heller, A. K.; Brenizer, J. S.

    Neutron radiography and its related two-dimensional (2D) neutron imaging techniques have been established as invaluable nondestructive inspection methods and quantitative measurement tools. They have been used in a wide variety of applications ranging from inspection of aircraft engine turbine blades to study of two-phase fluid flow in operating proton exchange membrane fuel cells. Neutron radiography is similar to X-ray radiography in that the method produces a 2D attenuation map of neutron radiation that has penetrated the object being examined. However, the images produced differ and are often complementary due to the differences between X-ray and neutron interaction mechanisms. The uses and types of 2D neutron imaging have expanded over the past 15 years as a result of advances in imaging technology and improvements in neutron generators/sources and computers. Still, high-intensity sources such as those from reactors and spallation neutron sources, together with conventional film radiography, remain the mainstay of high-resolution, large field-of-view neutron imaging. This chapter presents a summary of the history, methods, and related variations of neutron radiography techniques.

  8. X-Ray Absorption with Transmission X-Ray Microscopes

    NARCIS (Netherlands)

    de Groot, F.M.F.

    2016-01-01

    In this section we focus on the use of transmission X-ray microscopy (TXM) to measure the XAS spectra. In the last decade a range of soft X-ray and hard X-ray TXM microscopes have been developed, allowing the measurement of XAS spectra with 10–100 nm resolution. In the hard X-ray range the TXM

  9. X-ray Pulsars

    CERN Document Server

    Walter, Roland

    2016-01-01

    X-ray pulsars shine thanks to the conversion of the gravitational energy of accreted material to X-ray radiation. The accretion rate is modulated by geometrical and hydrodynamical effects in the stellar wind of the pulsar companions and/or by instabilities in accretion discs. Wind driven flows are highly unstable close to neutron stars and responsible for X-ray variability by factors $10^3$ on time scale of hours. Disk driven flows feature slower state transitions and quasi periodic oscillations related to orbital motion and precession or resonance. On shorter time scales, and closer to the surface of the neutron star, X-ray variability is dominated by the interactions of the accreting flow with the spinning magnetosphere. When the pulsar magnetic field is large, the flow is confined in a relatively narrow accretion column, whose geometrical properties drive the observed X-ray emission. In low magnetized systems, an increasing accretion rate allows the ignition of powerful explosive thermonuclear burning at t...

  10. X-ray Reflection

    Science.gov (United States)

    Fabian, A. C.; Ross, R. R.

    2010-12-01

    Material irradiated by X-rays produces backscattered radiation which is commonly known as the Reflection Spectrum. It consists of a structured continuum, due at high energies to the competition between photoelectric absorption and electron scattering enhanced at low energies by emission from the material itself, together with a complex line spectrum. We briefly review the history of X-ray reflection in astronomy and discuss various methods for computing the reflection spectrum from cold and ionized gas, illustrated with results from our own work reflionx. We discuss how the reflection spectrum can be used to obtain the geometry of the accretion flow, particularly the inner regions around black holes and neutron stars.

  11. Panoramic Dental X-Ray

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Panoramic Dental X-ray Panoramic dental x-ray uses a very small dose of ... x-ray , is a two-dimensional (2-D) dental x-ray examination that captures the entire mouth ...

  12. Chest X-Ray

    Medline Plus

    Full Text Available ... Therapy November 8 is the International Day of Radiology (IDoR) Radiology and You Sponsored by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, I’m Dr. Geoffrey ...

  13. X-ray tomography system for industrial applications

    Science.gov (United States)

    Auditore, L.; Barna, R. C.; Emanuele, U.; Loria, D.; Trifiro, A.; Trimarchi, M.

    2008-05-01

    X-ray radiography and tomography are two of the most used non-destructive testing techniques both in industrial and cultural heritage fields. However, the inspection of heavy materials or thick objects requires X-ray energies larger than the maximum energy provided by commercial X-ray tubes (600 kV). For this reason, and owing to the long experience of the INFN-Gruppo Collegato di Messina in designing and assembling low energy electron linacs, a 5 MeV electron linac based X-ray tomographic system has been developed at the Dipartimento di Fisica, Università di Messina. The X-ray source, properly designed, provides a 16 cm diameter X-ray spot at the sample position, and a beam opening angle of about 3.6 degree. Optimization of the parameters influencing the e-γ conversion and the X-ray beam characteristics have been studied by means of the MCNP-4C2 (Monte-Carlo-N-Particle, version 4C2) code. The image acquisition system consists of a CCD camera and a scintillator screen. Preliminary radiographies and tomographies showing the high quality performances of the tomographic system have been acquired. Finally, the compactness of the accelerator system is one of the advantages of the discussed tomography device which could be made transportable.

  14. Application of Slot full-length both lower extremities weight bearing position X-ray radiography in preoperative examination of total knee arthroplasty%Slot双下肢全长负重位X线摄影在全膝关节置换术前的应用

    Institute of Scientific and Technical Information of China (English)

    付丽媛; 梁永刚; 陈自谦; 刘冰川; 陈建新; 陈坚; 李超

    2011-01-01

    目的 观察Slot双下肢全长负重位X线检查技术在全膝关节置换术前检查中的应用价值.方法 对36例拟接受全膝关节置换术的患者术前行双下肢全长负重位X线检查.采用Slot技术,通过一次连续数秒曝光获得包含双髋关节至踝关节的双下肢全长负重位X线影像.结果 36例患者均一次性完成全膝关节置换术前双下肢全长负重位X线检查,其中膝关节内翻畸形34例,外翻畸形2例.所摄X线片中,患者双髋关节、股骨、膝关节、胫腓骨及踝关节均显示良好,可为术前计划提供可靠依据.结论 采用Slot双下肢全长负重位X线检查技术对拟接受全膝关节置换术患者进行术前检查,能够清晰显示双下肢全长,对术前计划与评估具有重要临床价值.%Objective To investigate the application value of Slot full-length both lower extremities weight bearing position X-ray radiography in the preoperative examination of total knee arthroplasty. Methods A retrospective analysis of full-length both lower extremities weight bearing position X-ray radiography in the preoperative examination of 36 patients scheduled for total knee arthroplasty was performed. Using Slot technology, bilateral hip joints to ankle joint images was obtained by exposing seconds continuously to get full-length both lower extremities weight bearing position X-ray. Results The full-length both lower extremities weight bearing position X-ray examination was one time completed in all 36 patients, including 34 of knee varus deformity and 2 of valgus deformity. Bilateral hip joints, femur, knee, tibia and fibula ankle joint were clearly displayed in the X-ray image, therefore providing a reliable X-ray image for the preoperative plan of total knee arthroplasty. Conclusion Slot full-length both lower extremities weight bearing position X-ray radiography can display full-length both lower extremities clearly, and has important clinical value in preoperative

  15. X-ray shout echoing through space

    Science.gov (United States)

    2004-01-01

    a flash of X-rays hi-res Size hi-res: 3991 Kb Credits: ESA, S. Vaughan (University of Leicester) EPIC camera shows the expanding rings caused by a flash of X-rays XMM-Newton's X-ray EPIC camera shows the expanding rings caused by a flash of X-rays scattered by dust in our Galaxy. The X-rays were produced by a powerful gamma-ray burst that took place on 3 December 2003. The slowly fading afterglow of the gamma-ray burst is at the centre of the expanding rings. Other, unrelated, X-ray sources can also be seen. The time since the gamma-ray explosion is shown in each panel in hours. At their largest size, the rings would appear in the sky about five times smaller than the full moon. a flash of X-rays hi-res Size hi-res: 2153 Kb Credits: ESA, S. Vaughan (University of Leicester) EPIC camera shows the expanding rings caused by a flash of X-rays (Please choose "hi-res" version for animation) XMM-Newton's X-ray EPIC camera shows the expanding rings caused by a flash of X-rays scattered by dust in our Galaxy. The X-rays were produced by a powerful gamma-ray burst that took place on 3 December 2003. The slowly fading afterglow of the gamma-ray burst is at the centre of the expanding rings. Other, unrelated, X-ray sources can also be seen. The time since the gamma-ray explosion is shown in each panel in seconds. At their largest size, the rings would appear in the sky about five times smaller than the full moon. This echo forms when the powerful radiation of a gamma-ray burst, coming from far away, crosses a slab of dust in our Galaxy and is scattered by it, like the beam of a lighthouse in clouds. Using the expanding rings to precisely pin-point the location of this dust, astronomers can identify places where new stars and planets are likely to form. On 3 December 2003 ESA's observatory, Integral, detected a burst of gamma rays, lasting about 30 seconds, from the direction of a distant galaxy. Within minutes of the detection, thanks to a sophisticated alert network, many

  16. X-ray Compton line scan tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kupsch, Andreas; Lange, Axel; Jaenisch, Gerd-Ruediger [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin (Germany). Fachgruppe 8.5 - Mikro-ZfP; Hentschel, Manfred P. [Technische Univ. Berlin (Germany); Kardjilov, Nikolay; Markoetter, Henning; Hilger, Andre; Manke, Ingo [Helmholtz-Zentrum Berlin (HZB) (Germany); Toetzke, Christian [Potsdam Univ. (Germany)

    2015-07-01

    The potentials of incoherent X-ray scattering (Compton) computed tomography (CT) are investigated. The imaging of materials of very different atomic number or density at once is generally a perpetual challenge for X-ray tomography or radiography. In a basic laboratory set-up for simultaneous perpendicular Compton scattering and direct beam attenuation tomography are conducted by single channel photon counting line scans. This results in asymmetric distortions of the projection profiles of the scattering CT data set. In a first approach, corrections of Compton scattering data by taking advantage of rotational symmetry yield tomograms without major geometric artefacts. A cylindrical sample composed of PE, PA, PVC, glass and wood demonstrates similar Compton contrast for all the substances, while the conventional absorption tomogram only reveals the two high order materials. Comparison to neutron tomography reveals astonishing similarities except for the glass component (without hydrogen). Therefore, Compton CT offers the potential to replace neutron tomography, which requires much more efforts.

  17. Digital chest radiography

    DEFF Research Database (Denmark)

    Debess, Jeanne Elisabeth; Vejle-Sørensen, Jens Kristian; Thomsen, Henrik;

    2015-01-01

    of clinical supervisors. Optimal collimation is determined by European and Regional Danish guidelines. The areal between current and optimal collimation is calculated. The experimental research is performed in September - October 2014 Siemens Axiom Aristos digital radiography system DR using 150 kV, 1,25 -3......Purpose: Quality improvement of basic radiography focusing on collimation and dose reduction in digital chest radiography Methods and Materials:A retrospective study of digital chest radiography is performed to evaluate the primary x-ray tube collimation of the PA and lateral radiographs. Data from...... one hundred fifty self-reliant female patients between 15 and 55 years of age are included in the study. The clinical research is performed between September and November 2014 where 3rd year Radiography students collect data on four Danish x-ray departments using identical procedures under guidance...

  18. Digital chest radiography

    DEFF Research Database (Denmark)

    Debess, Jeanne Elisabeth; Johnsen, Karen Kirstine; Thomsen, Henrik

    2015-01-01

    Background: Chest radiography is one of the most common examinations in radiology departments. In 2013 approximately 80,000 chest x-rays were performed on women in the fertile age. Even low dose for the examinationCorrect collimation Purpose: Quality improvement of basic radiography focusing...... collimations depending on side of radiograph. Results from dose reduction will be presented on the congress Conclusion: Correct positioning and collimation of digital chest radiographs can reduce the radiation dose significant to the patients and by that improve the quality of basic radiography....... on collimation and dose reduction in digital chest radiography Methods and Materials A retrospective study of digital chest radiography is performed to evaluate the primary x-ray tube collimation of the PA and lateral radiographs. Data from one hundred fifty self-reliant female patients between 15 and 55 years...

  19. X-Ray Astronomy

    Science.gov (United States)

    Wu, S. T.

    2000-01-01

    Dr. S. N. Zhang has lead a seven member group (Dr. Yuxin Feng, Mr. XuejunSun, Mr. Yongzhong Chen, Mr. Jun Lin, Mr. Yangsen Yao, and Ms. Xiaoling Zhang). This group has carried out the following activities: continued data analysis from space astrophysical missions CGRO, RXTE, ASCA and Chandra. Significant scientific results have been produced as results of their work. They discovered the three-layered accretion disk structure around black holes in X-ray binaries; their paper on this discovery is to appear in the prestigious Science magazine. They have also developed a new method for energy spectral analysis of black hole X-ray binaries; four papers on this topics were presented at the most recent Atlanta AAS meeting. They have also carried Monte-Carlo simulations of X-ray detectors, in support to the hardware development efforts at Marshall Space Flight Center (MSFC). These computation-intensive simulations have been carried out entirely on the computers at UAH. They have also carried out extensive simulations for astrophysical applications, taking advantage of the Monte-Carlo simulation codes developed previously at MSFC and further improved at UAH for detector simulations. One refereed paper and one contribution to conference proceedings have been resulted from this effort.

  20. X-ray lithography masking

    Science.gov (United States)

    Smith, Henry I. (Inventor); Lim, Michael (Inventor); Carter, James (Inventor); Schattenburg, Mark (Inventor)

    1998-01-01

    X-ray masking apparatus includes a frame having a supporting rim surrounding an x-ray transparent region, a thin membrane of hard inorganic x-ray transparent material attached at its periphery to the supporting rim covering the x-ray transparent region and a layer of x-ray opaque material on the thin membrane inside the x-ray transparent region arranged in a pattern to selectively transmit x-ray energy entering the x-ray transparent region through the membrane to a predetermined image plane separated from the layer by the thin membrane. A method of making the masking apparatus includes depositing back and front layers of hard inorganic x-ray transparent material on front and back surfaces of a substrate, depositing back and front layers of reinforcing material on the back and front layers, respectively, of the hard inorganic x-ray transparent material, removing the material including at least a portion of the substrate and the back layers of an inside region adjacent to the front layer of hard inorganic x-ray transparent material, removing a portion of the front layer of reinforcing material opposite the inside region to expose the surface of the front layer of hard inorganic x-ray transparent material separated from the inside region by the latter front layer, and depositing a layer of x-ray opaque material on the surface of the latter front layer adjacent to the inside region.

  1. Panoramic Dental X-Ray

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Panoramic Dental X-ray Panoramic dental x-ray uses a ... Your e-mail address: Personal message (optional): Bees: Wax: Notice: RadiologyInfo respects your privacy. Information entered here ...

  2. Soft X-ray Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Seely, John

    1999-05-20

    The contents of this report cover the following: (1) design of the soft x-ray telescope; (2) fabrication and characterization of the soft x-ray telescope; and (3) experimental implementation at the OMEGA laser facility.

  3. Multi-anode linear SDDs for high-resolution X-ray spectroscopy

    OpenAIRE

    Sonsky, J.

    2002-01-01

    Radiation detectors are used in a variety of fields to sense X-rays and y-rays, visible, UV and IR photons, neutrons or charged particles. With their help, advanced medical diagnostics can be performed (e.g. X-ray radiography, computed tomography, fluoroscopy), material research can undergo a rapid development (e.g. X-ray microanalysis, X-ray diffraction, Mauer spectroscopy and element imaging), space and its evolution (astronomy and astrophysics) can be explored through observation of X-rays...

  4. X-Ray Exam: Hip

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Hip KidsHealth > For Parents > X-Ray Exam: Hip A A A What's in ... español Radiografía: cadera What It Is A hip X-ray is a safe and painless test that ...

  5. X-Ray Exam: Finger

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Finger KidsHealth > For Parents > X-Ray Exam: Finger A A A What's in ... español Radiografía: dedo What It Is A finger X-ray is a safe and painless test that ...

  6. X-Ray Exam: Foot

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Foot KidsHealth > For Parents > X-Ray Exam: Foot A A A What's in ... español Radiografía: pie What It Is A foot X-ray is a safe and painless test that ...

  7. X-Ray Exam: Wrist

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Wrist KidsHealth > For Parents > X-Ray Exam: Wrist A A A What's in ... español Radiografía: muñeca What It Is A wrist X-ray is a safe and painless test that ...

  8. X-Ray Exam: Ankle

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Ankle KidsHealth > For Parents > X-Ray Exam: Ankle A A A What's in ... español Radiografía: tobillo What It Is An ankle X-ray is a safe and painless test that ...

  9. X-Ray Exam: Pelvis

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Pelvis KidsHealth > For Parents > X-Ray Exam: Pelvis A A A What's in ... español Radiografía: pelvis What It Is A pelvis X-ray is a safe and painless test that ...

  10. X-Ray Exam: Forearm

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Forearm KidsHealth > For Parents > X-Ray Exam: Forearm A A A What's in ... español Radiografía: brazo What It Is A forearm X-ray is a safe and painless test that ...

  11. X-ray selected BALQSOs

    CERN Document Server

    Page, M J; Ceballos, M; Corral, A; Ebrero, J; Esquej, P; Krumpe, M; Mateos, S; Rosen, S; Schwope, A; Streblyanska, A; Symeonidis, M; Tedds, J A; Watson, M G

    2016-01-01

    We study a sample of six X-ray selected broad absorption line (BAL) quasi-stellar objects (QSOs) from the XMM-Newton Wide Angle Survey. All six objects are classified as BALQSOs using the classic balnicity index, and together they form the largest sample of X-ray selected BALQSOs. We find evidence for absorption in the X-ray spectra of all six objects. An ionized absorption model applied to an X-ray spectral shape that would be typical for non-BAL QSOs (a power law with energy index alpha=0.98) provides acceptable fits to the X-ray spectra of all six objects. The optical to X-ray spectral indices, alpha_OX, of the X-ray selected BALQSOs, have a mean value of 1.69 +- 0.05, which is similar to that found for X-ray selected and optically selected non-BAL QSOs of similar ultraviolet luminosity. In contrast, optically-selected BALQSOs typically have much larger alpha_OX and so are characterised as being X-ray weak. The results imply that X-ray selection yields intrinsically X-ray bright BALQSOs, but their X-ray sp...

  12. X-ray Crystallography Facility

    Science.gov (United States)

    2000-01-01

    Edward Snell, a National Research Council research fellow at NASA's Marshall Space Flight Center (MSFC), prepares a protein crystal for analysis by x-ray crystallography as part of NASA's structural biology program. The small, individual crystals are bombarded with x-rays to produce diffraction patterns, a map of the intensity of the x-rays as they reflect through the crystal.

  13. Mechanized X-ray inspection system for large tanks

    Science.gov (United States)

    Occhipinti, G. C.

    1967-01-01

    Mechanized X ray equipment provides nondestructive inspection of structural weldments at various positions on very large tanks. It mechanizes the placement of the film, automates the identification process, adheres to safety requirements, and eliminates all the usual time-consuming manual operations in industrial radiography.

  14. SMM x ray polychromator

    Science.gov (United States)

    Saba, J. L. R.

    1993-01-01

    The objective of the X-ray Polychromator (XRP) experiment was to study the physical properties of solar flare plasma and its relation to the parent active region to understand better the flare mechanism and related solar activity. Observations were made to determine the temperature, density, and dynamic structure of the pre-flare and flare plasma as a function of wavelength, space and time, the extent to which the flare plasma departs from thermal equilibrium, and the variation of this departure with time. The experiment also determines the temperature and density structure of active regions and flare-induced changes in the regions.

  15. X-ray lithography source

    Science.gov (United States)

    Piestrup, Melvin A.; Boyers, David G.; Pincus, Cary

    1991-01-01

    A high-intensity, inexpensive X-ray source for X-ray lithography for the production of integrated circuits. Foil stacks are bombarded with a high-energy electron beam of 25 to 250 MeV to produce a flux of soft X-rays of 500 eV to 3 keV. Methods of increasing the total X-ray power and making the cross section of the X-ray beam uniform are described. Methods of obtaining the desired X-ray-beam field size, optimum frequency spectrum and elminating the neutron flux are all described. A method of obtaining a plurality of station operation is also described which makes the process more efficient and economical. The satisfying of these issues makes transition radiation an exellent moderate-priced X-ray source for lithography.

  16. Clinical, X-ray radiography and CT features of pulmonary Langerhans cell histiocytosis (two cases report and literature review)%肺郎格汉斯细胞组织细胞增生症的临床、X线、CT表现(2例报告并文献复习)

    Institute of Scientific and Technical Information of China (English)

    刘晓红; 印建国; 石新霞; 宋锦文

    2012-01-01

    目的 探讨肺郎格汉斯细胞组织细胞增生症(PLCH)的临床、X线及CT表现,以提高对该病的影像学认识.方法 回顾性分析2例病理证实的PLCH患者的临床、X线和CT资料.2例患者均行胸部螺旋CT、高分辨CT(HRCT)扫描及X线胸部平片摄影,1例行头颅CT扫描.结果 2例患者CT及HRCT均为双中上肺野广泛分布的高密度小结节状影、纤维条索影及囊状和蜂窝状影.1例头颅CT示右枕骨局限性骨质破坏;胸部平片示双肺野透光度减低,双肺纹理模糊;另1例胸部平片示双肺纹理紊乱,右肺中野可见多个小囊状低密度区;纵隔影明显增宽.结论 PLCH的X线、CT及HRCT表现有一定的特征性,尤其是HRCT显示病变更加清晰,结合临床资料可提高对此病的诊断,确诊仍需病理学诊断.%Objective To investigate the clinical, X-ray and CT findings of pulmonary Langerhans cell histiocytic hyperplasia (PLCH) , improve the imaging recognition of PLCH. Methods Clinical, X-ray and CT data of two patients with pathologically confirmed PLCH were retrospectively analyzed. Two patients underwent chest spiral CT examination including high resolution CT ( HRCT) scan and chest X-ray radiography. Head CT scan was performed in one patient. Results Widely distributed high-density small nodules, fibrous bands, cystic and honeycomb shadow in the lung fields was revealed on the CT and HRCT in two patients. Head CT in one patient showed limited bone destruction in right occipital bone. Chest X-ray radiography showed dual lung field transmittance is reduced dual markings vague; one cases of chest plain film shows pairs of markings and more chaos, right lung in the wild can be seen a number of small cystic low-density areas; obviously enlarged mediastinal shadow. Conclusion PLCH has certain characteristics on the CT and X-ray radiography, especially on HRCT. HRCT can show the lesions more clearly. The radiological findings combined with clinical data can

  17. The LHC goes in for an X-ray

    CERN Multimedia

    Anaïs Vernède

    2011-01-01

    For the past two years, a radiography laboratory has been operating in a "bunker" where it can X-ray materials in complete safety. The primary function of the radiography laboratory, run by Jean-Michel Dalin and Aline Piguiet, is to inspect welds and LHC components.   Technicians Jean-Michel Dalin and Aline Piguiet, from the EN department,  with the scanner used for digital radiography. In the basement of Building 112 lies a bunker heavily protected against radiation leaks and housing a laboratory that employs high-tech apparatus capable of detecting the slightest fault in materials without destroying or damaging them. "It's the principle of Non-Destructive Testing (NDT). In our laboratory we essentially use two methods, tomography and digital radiography," explains Jean-Michel Dalin, who is a NDT radiography technician in the EN Department's MM Section. It was he who designed the laboratory in collaboration with CERN's radiation protection service, wh...

  18. Multi-anode linear SDDs for high-resolution X-ray spectroscopy

    NARCIS (Netherlands)

    Sonsky, J.

    2002-01-01

    Radiation detectors are used in a variety of fields to sense X-rays and y-rays, visible, UV and IR photons, neutrons or charged particles. With their help, advanced medical diagnostics can be performed (e.g. X-ray radiography, computed tomography, fluoroscopy), material research can undergo a rapid

  19. Multi-anode linear SDDs for high-resolution X-ray spectroscopy

    NARCIS (Netherlands)

    Sonsky, J.

    2002-01-01

    Radiation detectors are used in a variety of fields to sense X-rays and y-rays, visible, UV and IR photons, neutrons or charged particles. With their help, advanced medical diagnostics can be performed (e.g. X-ray radiography, computed tomography, fluoroscopy), material research can undergo a rapid

  20. X-Ray parameters of lumbar spine

    Directory of Open Access Journals (Sweden)

    Otabek Ablyazov

    2012-05-01

    Full Text Available Knowledge of anatomic spinal structures, especially its relation-ship to the functions performed, is necessary to form a correct diagnosis. The anatomical structure of the vertebrae varies de-pending on the level of the spinal segment. Normal anatomical parameters, derived from bone structures of the spine, are roughly determined by X-ray method.This paper presents the results of the survey radiography of the lumbar spine in a straight line and lateral projections in 30 individ-uals without pathology spine, aged 21-60 years with frequently observed lumbar spinal stenosis stenosis. Applying X-ray method there were studied shape, height, and the contours of the vertebral bodies and intervertebral disc in the front (interpedicular and sagittal planes; there were measured dimensions of the lumbar canal and foramen holes in the same planes. Using X-ray method can fully identify the bone parameters of vertebral column. How-ever, the informativity of the method depends on knowledge of radiologist about topographic anatomical features of spine.

  1. Experimental and theoretical characterisation of short pulse X ray lasers

    CERN Document Server

    Strati, F

    2002-01-01

    Since the demonstration in 1984 of x-ray laser action in Ne-like Se at 20.6 and 20.9 nm, much experimental and theoretical effort has been ongoing to investigate different lasing schemes. Aims in this research include improving pumping efficiency, beam quality and overall energy output of the demonstrated x-ray lasers and the production of lasing at shorter wavelengths. The envisaged and demonstrated applications of x-ray lasers utilise their short wavelength, high brightness and coherence. Examples of potential applications include x-ray imaging and holography of biological materials in the water window region (2.3 - 4.4 nm), x-ray photolithography for the fabrication of microcircuits and structures below the micron scale and x-ray interferometry, deflectometry and radiography of dense plasma environments of interest in inertial confinement fusion and astrophysics. Soft x-ray laser action has been demonstrated in various plasma active media with wavelengths ranging from 3.5 nm to 40.0 nm and above. However, ...

  2. A Compare Research on Accuracy of X-ray Radiography and SybronEndo Apex Locator for Measuring Root Canal Working Length%X线插针摄片技术与SybronEndo根尖定位仪测量根管工作长度准确性的比较研究

    Institute of Scientific and Technical Information of China (English)

    翁巧凤

    2013-01-01

    目的根管治疗包括根管预备、根管消毒和根管充填。准确地测量根管工作长度是根管预备和根管充填必不可少的条件。方法抽取96颗前牙,分 A、B两组,在根管预备前分别应用X线插针摄片法、SybronEndo根尖定位仪法进行根管工作长度测量,以此长度进行根管预备和充填,然后摄 X线牙片,比较其恰充率。结果用X线插针摄片法和SybronEndo根管测量仪法指导的根管充填成功率分别为64.58%和81.25%(P<0.01),有显著性差异。结论 SybronEndo根管测量仪是一种准确率较高的根管工作长度测量工具,将成为今后临床测量根管工作长度的首选可行方法。%Objective The root canal therapy includes Root canal preparation, disinfection of root canal and root canal fil ing. The accurate measurement of root canal working length is indispensable condition of root canal preparation and root canal fil ing. Methods Extraction of 96 front teeth, divide into A, B two groups, X-ray radiography and SybronEndo apex locator for measuring root canal working length in the respectively application of root canal preparation.The root canal preparation and root canal fil ing in this length, then x-ray radiograph, Comparison of the appropriate fil ing rate. Result Use X-ray radiography and SybronEndo apex locator for measuring root canal working length to guide the success rate of root canal fil ing are 64.58%and 81.25%, respectively (P<0.01) there is a significant dif erences. Conclusion The SybronEndo apex locator is a kind of high accuracy of root canal working length measurement.It wil become the preferred method of future clinical measurement of root canal working length.

  3. Topological X-Rays Revisited

    Science.gov (United States)

    Lynch, Mark

    2012-01-01

    We continue our study of topological X-rays begun in Lynch ["Topological X-rays and MRI's," iJMEST 33(3) (2002), pp. 389-392]. We modify our definition of a topological magnetic resonance imaging and give an affirmative answer to the question posed there: Can we identify a closed set in a box by defining X-rays to probe the interior and without…

  4. [Flat-panel detectors in X-ray systems].

    Science.gov (United States)

    Spahn, M; Heer, V; Freytag, R

    2003-05-01

    For all application segments X-ray systems with flat-panel detectors increasingly enter the market. In digital radiography,mammography and cardiologic angiography flat-panel detectors are already well established while they are made ready for market introduction in general angiography and fluoroscopy. Two flat-panel detector technologies are available. One technology is based on an indirect conversion process of X-rays while the other one uses a direct conversion method. For radiography and dynamic applications the indirect method provides substantial advantages, while the direct method has some benefits for mammography. In radiography and mammography flat-panel detectors lead to clear improvements with respect to workflow, image quality and dose reduction potentials. These improvements are fostered by the immediate availability of the image, the large dynamic range and the high sensitivity to X-rays. New applications and the use of complex image processing algorithms have the potential to enlarge the present diagnostic range of applications. Up to now, image intensifiers are still the well-established technology for angiography and fluoroscopy. Nevertheless flat-panel detectors begin to enter this field, especially in cardiologic angiography. Characteristics of flat-panel detectors such as the availability of distortion-free images, the excellent contrast resolution, the large dynamic range, the high sensitivity to X-rays and the usability in magnetic fields provide the basis for improved and new diagnostic and interventional methods.

  5. X-ray instrumentation for SR beamlines

    CERN Document Server

    Kovalchuk, M V; Zheludeva, S I; Aleshko-Ozhevsky, O P; Arutynyan, E H; Kheiker, D M; Kreines, A Y; Lider, V V; Pashaev, E M; Shilina, N Y; Shishkov, V A

    2000-01-01

    The main possibilities and parameters of experimental X-ray stations are presented: 'Protein crystallography', 'X-ray structure analysis', 'High-precision X-ray optics', 'X-ray crystallography and material science', 'X-ray topography', 'Photoelectron X-ray standing wave' that are being installed at Kurchatov SR source by A.V. Shubnikov Institute of Crystallography.

  6. X-ray Fluorescence Sectioning

    CERN Document Server

    Cong, Wenxiang

    2012-01-01

    In this paper, we propose an x-ray fluorescence imaging system for elemental analysis. The key idea is what we call "x-ray fluorescence sectioning". Specifically, a slit collimator in front of an x-ray tube is used to shape x-rays into a fan-beam to illuminate a planar section of an object. Then, relevant elements such as gold nanoparticles on the fan-beam plane are excited to generate x-ray fluorescence signals. One or more 2D spectral detectors are placed to face the fan-beam plane and directly measure x-ray fluorescence data. Detector elements are so collimated that each element only sees a unique area element on the fan-beam plane and records the x-ray fluorescence signal accordingly. The measured 2D x-ray fluorescence data can be refined in reference to the attenuation characteristics of the object and the divergence of the beam for accurate elemental mapping. This x-ray fluorescence sectioning system promises fast fluorescence tomographic imaging without a complex inverse procedure. The design can be ad...

  7. Soft X-ray optics

    CERN Document Server

    Spiller, Eberhard A

    1993-01-01

    This text describes optics mainly in the 10 to 500 angstrom wavelength region. These wavelengths are 50 to 100 times shorter than those for visible light and 50 to 100 times longer than the wavelengths of medical x rays or x-ray diffraction from natural crystals. There have been substantial advances during the last 20 years, which one can see as an extension of optical technology to shorter wavelengths or as an extension of x-ray diffraction to longer wavelengths. Artificial diffracting structures like zone plates and multilayer mirrors are replacing the natural crystals of x-ray diffraction.

  8. X-ray Absorption Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Yano, Junko; Yachandra, Vittal K.

    2009-07-09

    This review gives a brief description of the theory and application of X-ray absorption spectroscopy, both X-ray absorption near edge structure (XANES) and extended X-ray absorption fine structure (EXAFS), especially, pertaining to photosynthesis. The advantages and limitations of the methods are discussed. Recent advances in extended EXAFS and polarized EXAFS using oriented membranes and single crystals are explained. Developments in theory in understanding the XANES spectra are described. The application of X-ray absorption spectroscopy to the study of the Mn4Ca cluster in Photosystem II is presented.

  9. X-ray variability with WFXT: AGNs, transients and more

    CERN Document Server

    Paolillo, Maurizio; Allevato, Viola; de Martino, Domitilla; della Valle, Massimo; Papadakis, Iossif; Gilli, Roberto; Tozzi, Paolo

    2010-01-01

    The Wide Field X-ray Telescope (WFXT) is a proposed mission with a high survey speed, due to the combination of large field of view (FOV) and effective area, i.e. grasp, and sharp PSF across the whole FOV. These characteristics make it suitable to detect a large number of variable and transient X-ray sources during its operating lifetime. Here we present estimates of the WFXT capabilities in the time domain, allowing to study the variability of thousand of AGNs with significant detail, as well as to constrain the rates and properties of hundreds of distant, faint and/or rare objects such as X-ray Flashes/faint GRBs, Tidal Disruption Events, ULXs, Type-I bursts etc. The planned WFXT extragalactic surveys will thus allow to trace variable and transient X-ray populations over large cosmological volumes.

  10. X射线胸部摄影曝光剂量与图像质量相关性研究%Study on correlation between exposure dose and image quality of X-ray chest radiography

    Institute of Scientific and Technical Information of China (English)

    曹允希; 蔡小涛; 谢晋东; 曹鑫

    2014-01-01

    Objective To investigate optimal radiation dose for digital radiography by researching the correlation between radiation dose and image quality of high kV chest radiography.Methods The kV of chest radiography was setted on 120 kV while mAs was changed.The chest radiography phantom and the contrast detail phantom CDRAD2.0 were exposed by DR with different mAs from 1 to 25 mAs.The entrance doses were measured for all exposures and the images were read independently by 5 observers on a higher resolution monitor of diagnosis work station.The image quality figure (IQF) was measured for each image.Comparison of the mean IQFs with different exposure doses were conducted in order to determined which was the optimal exposure condition for high kV radiography.The image quality of normal adult using different mAs,4 and 10 mAs for high KV chest radiography was compared.Results When the mAs was increased from 1 to 25 mAs,the entrance doses varied from 0.067 to 1.468 mGy.With the entrance doses increasing,the value of IQF was decreased (F =31.00,P < 0.05).The values of IQF were statistically different between 1 and 4 mAs(F =15.3,P <0.05),and between 10 and 25 mAs(F =9.74,P <0.05).At 4 and 10 mAs with the entrance dose 0.250 and 0.606 mGy,the synthesis score of chest high kV radiography from two kinds of exposure dose was (24.8 ± 1.64),(25.8 ± 2.05),with no statistically significant difference.Conclusions For digital radiography,increasing radiation dose can improve image information.The optimal entrance dose of high kV chest radiography for standard body was about 0.250 mGy.%目的 研究数字化X射线胸部高千伏摄影曝光剂量与图像质量的关系,确定数字化X射线摄影最佳曝光剂量.方法 选择胸部高千伏摄影管电压120 kV,摄影mAs从1 mAs逐档增加至25 mAs,对模拟人体胸部厚度摄影体模与CDRAD 2.0对比度细节体模进行摄影,测量体模表面X射线入射剂量,由5位观察者独立阅读体模影像,比较任意两

  11. Near Edge X-Ray Absorption Fine Structure Spectroscopy with X-Ray Free-Electron Lasers

    Energy Technology Data Exchange (ETDEWEB)

    Bernstein, D.P.; Acremann, Y.; Scherz, A.; Burkhardt, M.; Stohr, J.; /SLAC; Beye, M.; Schlotter, W.F.; Beeck, T.; Sorgenfrei, F.; Pietzsch, A.; Wurth, W.; Fohlisch, A.; /Hamburg U.

    2009-12-11

    We demonstrate the feasibility of Near Edge X-ray Absorption Fine Structure (NEXAFS) spectroscopy on solids by means of femtosecond soft x-ray pulses from a free-electron laser (FEL). Our experiments, carried out at the Free-Electron Laser at Hamburg (FLASH), used a special sample geometry, spectrographic energy dispersion, single shot position-sensitive detection and a data normalization procedure that eliminates the severe fluctuations of the incident intensity in space and photon energy. As an example we recorded the {sup 3}D{sub 1} N{sub 4,5}-edge absorption resonance of La{sup 3+}-ions in LaMnO{sub 3}. Our study opens the door for x-ray absorption measurements on future x-ray FEL facilities.

  12. Diffraction enhanced X-ray imaging of mammals crystalline lens

    Energy Technology Data Exchange (ETDEWEB)

    Antunes, A. [Departamento de Fisica Aplicada, USP, CP 66318, 05315-970 Sao Paulo, SP (Brazil)]. E-mail: antunes@if.usp.br; Hoennicke, M.G. [LORXI, Departamento de Fisica, Universidade Federal do Parana, Curitiba (Brazil); Safatle, A.M.V. [Faculdade de Medicina Veterinaria e Zootecnia, USP, 05508-900 Sao Paulo, SP (Brazil); Cusatis, C. [LORXI, Departamento de Fisica, Universidade Federal do Parana, Curitiba (Brazil); Moraes Barros, P.S. [Faculdade de Medicina Veterinaria e Zootecnia, USP, 05508-900 Sao Paulo, SP (Brazil); Morelhao, S.L. [Departamento de Fisica Aplicada, USP, CP 66318, 05315-970 Sao Paulo, SP (Brazil)

    2005-08-15

    Crystalline lenses are transparent biological materials where the organization of the lens fibers can also be affected by changes at molecular level, and therefore the structure and morphology of the tissue can be correlated to the loss of transparency of the lens. In this work, internal structure of mammal lenses regarding the long-range ordering of the fibers are investigated by diffraction enhanced X-ray imaging (DEI) radiography. Moreover, DEI and absorption X-ray synchrotron radiographs for healthy and cataractous crystalline lenses are compared. Significant differences in healthy and cataractous crystalline lenses are observed.

  13. Focusing X-Ray Telescopes

    Science.gov (United States)

    O'Dell, Stephen; Brissenden, Roger; Davis, William; Elsner, Ronald; Elvis, Martin; Freeman, Mark; Gaetz, Terrance; Gorenstein, Paul; Gubarev, Mikhall; Jerlus, Diab; Juda, Michael; Kolodziejczak, Jeffrey; Murray, Stephen; Petre, Robert; Podgorski, William; Ramsey, Brian; Reid, Paul; Saha, Timo; Wolk, Scott; Troller-McKinstry, Susan; Weisskopf, Martin; Wilke, Rudeger; Zhang, William

    2010-01-01

    During the half-century history of x-ray astronomy, focusing x-ray telescopes, through increased effective area and finer angular resolution, have improved sensitivity by 8 orders of magnitude. Here, we review previous and current x-ray-telescope missions. Next, we describe the planned next-generation x-ray-astronomy facility, the International X-ray Observatory (IXO). We conclude with an overview of a concept for the next next-generation facility, Generation X. Its scientific objectives will require very large areas (about 10,000 sq m) of highly-nested, lightweight grazing-incidence mirrors, with exceptional (about 0.1-arcsec) resolution. Achieving this angular resolution with lightweight mirrors will likely require on-orbit adjustment of alignment and figure.

  14. X-Ray Tomographic Reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Bonnie Schmittberger

    2010-08-25

    Tomographic scans have revolutionized imaging techniques used in medical and biological research by resolving individual sample slices instead of several superimposed images that are obtained from regular x-ray scans. X-Ray fluorescence computed tomography, a more specific tomography technique, bombards the sample with synchrotron x-rays and detects the fluorescent photons emitted from the sample. However, since x-rays are attenuated as they pass through the sample, tomographic scans often produce images with erroneous low densities in areas where the x-rays have already passed through most of the sample. To correct for this and correctly reconstruct the data in order to obtain the most accurate images, a program employing iterative methods based on the inverse Radon transform was written. Applying this reconstruction method to a tomographic image recovered some of the lost densities, providing a more accurate image from which element concentrations and internal structure can be determined.

  15. X-Ray Diffraction Apparatus

    Science.gov (United States)

    Blake, David F. (Inventor); Bryson, Charles (Inventor); Freund, Friedmann (Inventor)

    1996-01-01

    An x-ray diffraction apparatus for use in analyzing the x-ray diffraction pattern of a sample is introduced. The apparatus includes a beam source for generating a collimated x-ray beam having one or more discrete x-ray energies, a holder for holding the sample to be analyzed in the path of the beam, and a charge-coupled device having an array of pixels for detecting, in one or more selected photon energy ranges, x-ray diffraction photons produced by irradiating such a sample with said beam. The CCD is coupled to an output unit which receives input information relating to the energies of photons striking each pixel in the CCD, and constructs the diffraction pattern of photons within a selected energy range striking the CCD.

  16. X-ray bursters and the X-ray sources of the galactic bulge

    Science.gov (United States)

    Lewin, W. H. G.; Joss, P. C.

    1981-01-01

    An attempt is made to distill from observational and theoretical information on the galactic bulge X-ray sources in general, and on the X-ray burst sources in particular, those aspects which seem to have the greatest relevance to the understanding of these sources. Galactic bulge sources appear to be collapsed objects of roughly solar mass, in most cases neutron stars, which are accreting matter from low-mass stellar companions. Type I bursts seem to result from thermonuclear flashes in the surface layers of some of these neutron stars, while the type II bursts from the Rapid Burster are almost certainly due to an instability in the accretion flow onto a neutron star. It is concluded that the studies cited offer a new and powerful observational handle on the fundamental properties of neutron stars and of the interacting binary systems in which they are often contained.

  17. X-ray monitoring optical elements

    Energy Technology Data Exchange (ETDEWEB)

    Stoupin, Stanislav; Shvydko, Yury; Katsoudas, John; Blank, Vladimir D.; Terentyev, Sergey A.

    2016-12-27

    An X-ray article and method for analyzing hard X-rays which have interacted with a test system. The X-ray article is operative to diffract or otherwise process X-rays from an input X-ray beam which have interacted with the test system and at the same time provide an electrical circuit adapted to collect photoelectrons emitted from an X-ray optical element of the X-ray article to analyze features of the test system.

  18. X-ray diagnostics for TFTR

    Energy Technology Data Exchange (ETDEWEB)

    von Goeler, S.; Hill, K.W.; Bitter, M.

    1982-12-01

    A short description of the x-ray diagnostic preparation for the TFTR tokamak is given. The x-ray equipment consists of the limiter x-ray monitoring system, the soft x-ray pulse-height-analysis-system, the soft x-ray imaging system and the x-ray crystal spectrometer. Particular attention is given to the radiation protection of the x-ray systems from the neutron environment.

  19. Semiconductor X-ray detectors

    CERN Document Server

    Lowe, Barrie Glyn

    2014-01-01

    Identifying and measuring the elemental x-rays released when materials are examined with particles (electrons, protons, alpha particles, etc.) or photons (x-rays and gamma rays) is still considered to be the primary analytical technique for routine and non-destructive materials analysis. The Lithium Drifted Silicon (Si(Li)) X-Ray Detector, with its good resolution and peak to background, pioneered this type of analysis on electron microscopes, x-ray fluorescence instruments, and radioactive source- and accelerator-based excitation systems. Although rapid progress in Silicon Drift Detectors (SDDs), Charge Coupled Devices (CCDs), and Compound Semiconductor Detectors, including renewed interest in alternative materials such as CdZnTe and diamond, has made the Si(Li) X-Ray Detector nearly obsolete, the device serves as a useful benchmark and still is used in special instances where its large, sensitive depth is essential. Semiconductor X-Ray Detectors focuses on the history and development of Si(Li) X-Ray Detect...

  20. Neutron and X-ray Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Carini, Gabriella [SLAC National Accelerator Lab., Menlo Park, CA (United States); Denes, Peter [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Gruener, Sol [Cornell Univ., Ithaca, NY (United States); Lessner, Elianne [Dept. of Energy (DOE), Washington DC (United States). Office of Science Office of Basic Energy Sciences

    2012-08-01

    : Improvements in the readout speed and energy resolution of X-ray detectors are essential to enable chemically sensitive microscopies. Advances would make it possible to take images with simultaneous spatial and chemical information. Very high-energy-resolution X-ray detectors: The energy resolution of semiconductor detectors, while suitable for a wide range of applications, is far less than what can be achieved with X-ray optics. A direct detector that could rival the energy resolution of optics could dramatically improve the efficiency of a multitude of experiments, as experiments are often repeated at a number of different energies. Very high-energy-resolution detectors could make these experiments parallel, rather than serial. Low-background, high-spatial-resolution neutron detectors: Low-background detectors would significantly improve experiments that probe excitations (phonons, spin excitations, rotation, and diffusion in polymers and molecular substances, etc.) in condensed matter. Improved spatial resolution would greatly benefit radiography, tomography, phase-contrast imaging, and holography. Improved acquisition and visualization tools: In the past, with the limited variety of slow detectors, it was straightforward to visualize data as it was being acquired (and adjust experimental conditions accordingly) to create a compact data set that the user could easily transport. As detector complexity and data rates explode, this becomes much more challenging. Three goals were identified as important for coping with the growing data volume from high-speed detectors: Facilitate better algorithm development. In particular, algorithms that can minimize the quantity of data stored. Improve community-driven mechanisms to reduce data protocols and enhance quantitative, interactive visualization tools. Develop and distribute community-developed, detector-specific simulation tools. Aim for parallelization to take advantage of high-performance analysis platforms. Improved analysis

  1. Coherent methods in X-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Gorobtsov, Oleg

    2017-05-15

    X-ray radiation has been used to study structural properties of materials for more than a hundred years. Construction of extremely coherent and bright X-ray radiation sources such as free electron lasers (FELs) and latest generationstorage rings led to rapid development of experimental methods relying on high radiation coherence. These methods allow to perform revolutionary studies in a wide range of fields from solid state physics to biology. In this thesis I focus on several important problems connected with the coherent methods. The first part considers applications of dynamical diffraction theory on crystals to studies with coherent X-ray radiation. It presents the design of a high-resolution spectrometer for free electron lasers that should allow to resolve spectral structure of individual FEL pulses. The spectrometer is based on the principle of dynamical diffraction focusing. The knowledge of individual FEL pulse spectra is necessary for understanding FEL longitudinal coherence. In the same part I present quasi-kinematical approximation to dynamical theory which allows to treat analytically phase effects observed in X-ray coherent imaging on nanocrystals. These effects may play a big role when methods such as ptychography are used to study crystalline samples. The second part deals with measurements of FEL coherence properties using intensity - intensity interferometry. Results of several experiments performed at FELs FLASH and LCLS are revealed in this section. I have developed models and theories to explain the behavior observed in experiments on FLASH. These models allowed to extract information about external positional jitter of FEL pulses and secondary beams present in FEL radiation. In the LCLS experiment the Hanbury Brown and Twiss type interferometry was performed on Bragg peaks from colloidal crystal. This did not require additional measurements without the sample and information was extracted directly from diffraction patterns. Therefore intensity

  2. Primary study on the evaluation for the treatment of functional dyspepsia with acupuncture by Dynamic X-ray radiography with gastric barium meal%X 线胃钡餐动态摄影评价针刺治疗功能性消化不良的初步研究

    Institute of Scientific and Technical Information of China (English)

    赵青; 金玉莲; 洪洋; 方继良; 刘志顺; 景向红; 喻晓春; 朱兵

    2014-01-01

    Objective It is to evaluate the changes of gastric motility, serum gastrin and clinical symptom scores after one month's treatment with acupuncture and their relationship in the patients with functional dyspepsia ( FD) by dynamic X-ray radiography with gastric barium meal .Methods Seventeen FD patients were selected according with the Rome III criteria , and their clinical FD scores were evaluated and received examination of dynamic X -ray radiography with barium meal , in which 8 cases were treated with acupuncture for 1 month and were given examination of dynamic X -ray radiography with barium meal , fasting serum gastrin measure and symptom score evaluation before and after treatment .10 normal people were selected as con-trol group and given the same examination .The imaging indexes of X -ray included the height of gastric retention liquid , the width of midgastric transverse band ( MTR) ,the frequency , width and depth of gastric slow waves .Results It showed signifi-cant differences between FD patients and healthy subjects in the imaging indexes of gastric motility including the height of gas -tric retention liquid,MTR,the frequency of stomach wave (P all <0.01).After one weeks'acupuncture in FD patients,single and total symptom scores were significantly decreased (P<0.01), gastric retention liquid and MTR were decreased (P<0.01 or P<0.05), frequency of gastric slow waves was fasted (P<0.01), propagation velocity of gastric slow waves was shortened (P<0.05), the level of serum gastrin was increaed (P<0.01).the outcomes showed these indexes were improved to the normal values closely .In the treatment with acupuncture for FD , gastric motility index was in accordance with the changes of symptom index and serum gastrin .Conclusion The dynamic X-ray radiography with gastric barium meal can be a practical and cheap diagnosis method in evaluating for gastric motility disorder in FD .Acupuncture could treat for FD may through in-creasing the level of serum gastrin

  3. MIXI: Mobile Intelligent X-Ray Inspection System

    Science.gov (United States)

    Arodzero, Anatoli; Boucher, Salime; Kutsaev, Sergey V.; Ziskin, Vitaliy

    2017-07-01

    A novel, low-dose Mobile Intelligent X-ray Inspection (MIXI) concept is being developed at RadiaBeam Technologies. The MIXI concept relies on a linac-based, adaptive, ramped energy source of short X-ray packets of pulses, a new type of fast X-ray detector, rapid processing of detector signals for intelligent control of the linac, and advanced radiography image processing. The key parameters for this system include: better than 3 mm line pair resolution; penetration greater than 320 mm of steel equivalent; scan speed with 100% image sampling rate of up to 15 km/h; and material discrimination over a range of thicknesses up to 200 mm of steel equivalent. Its minimal radiation dose, size and weight allow MIXI to be placed on a lightweight truck chassis.

  4. X-rays, gamma-rays and neutrinos from collisoinless shocks in supernova wind breakouts

    CERN Document Server

    Katz, Boaz; Waxman, Eli

    2011-01-01

    We show that a collisionless shock necessarily forms during the shock breakout of a supernova (SN) surrounded by an optically thick wind. An intense non-thermal flash of <~ MeV gamma rays, hard X-rays and multi-TeV neutrinos is produced simultaneously with and following the soft X-ray breakout emission, carrying similar or larger energy than the soft emission. The non-thermal flash is detectable by current X-ray telescopes and may be detectable out to 10's of Mpc by km-scale neutrino telescopes.

  5. On the X-Ray emission of Gamma Ray Bursts

    CERN Document Server

    Dado, Shlomo; De Rújula, Alvaro

    2007-01-01

    Recent data gathered and triggered by the SWIFT satellite have greatly improved our knowledge of long-duration gamma ray bursts (GRBs) and X-ray flashes (XRFs). This is particularly the case for the X-ray data at all times. We show that the entire X-ray observations are in excellent agreement with the predictions of the `cannonball' model of GRBs and XRFs, which are based on simple physics and were published long before the launch of SWIFT. Two mechanisms underlie these predictions: inverse Compton scattering and synchrotron radiation, generally dominant at early and late times, respectively. The former mechanism provides a unified description of the gamma-ray peaks, X-ray flares and even the optical `humps' seen in some favourable cases; i.e. their very different durations, fluxes and peak-times are related precisely as predicted. The observed smooth or bumpy fast decay of the X-ray light curve is correctly described case-by-case, in minute detail. The `canonical' X-ray plateau, as well as the subsequent gra...

  6. The CZT X-ray Imager on AXO

    Science.gov (United States)

    Budtz-Jørgensen, C.; Kuvvetli, I.; Westergaard, N. J.; Jonasson, P.; Reglero, V.; Eyles, C.; Neubert, T.

    2001-03-01

    DSRI has initiated a development program of CZT X-ray and gamma ray detectors employing strip readout techniques. A dramatic improvement of the energy response was found operating the detectors as so-called drift detectors. For the electronic readout, modern ASIC chips were investigated. Modular design and the low power electronics will make large area detectors using the drift strip method feasible. The performance of a prototype CZT system will be presented and discussed. One such detector system has been proposed for future space missions: The X-Ray Imager (XRI) on the Atmospheric X-ray Observatory (AXO), which is a mission proposed to the Danish Small Satellite Program and is dedicated to observations of X-ray generating processes in the Earth's atmosphere. Of special interest will be simultaneous optical and X-ray observations of sprites that are flashes appearing directly above an active thunderstorm system. Additional objective is a detailed mapping of the auroral X-ray and optical emission. XRI comprises a coded mask and a 20 cm × 40 cm CZT detector array covering an energy range from 5 to 200 keV.

  7. CELESTIAL X-RAY SOURCES.

    Science.gov (United States)

    sources, (4) the physical conditions in the pulsating x-ray source in the Crab Nebula , and (5) miscellaneous related topics. A bibliography of all work performed under the contract is given. (Author)

  8. X-Ray Assembler Data

    Data.gov (United States)

    U.S. Department of Health & Human Services — Federal regulations require that an assembler who installs one or more certified components of a diagnostic x-ray system submit a report of assembly. This database...

  9. Electromechanical x-ray generator

    Energy Technology Data Exchange (ETDEWEB)

    Watson, Scott A; Platts, David; Sorensen, Eric B

    2016-05-03

    An electro-mechanical x-ray generator configured to obtain high-energy operation with favorable energy-weight scaling. The electro-mechanical x-ray generator may include a pair of capacitor plates. The capacitor plates may be charged to a predefined voltage and may be separated to generate higher voltages on the order of hundreds of kV in the AK gap. The high voltage may be generated in a vacuum tube.

  10. Accelerator x-ray sources

    CERN Document Server

    Talman, Richard

    2007-01-01

    This first book to cover in-depth the generation of x-rays in particle accelerators focuses on electron beams produced by means of the novel Energy Recovery Linac (ERL) technology. The resulting highly brilliant x-rays are at the centre of this monograph, which continues where other books on the market stop. Written primarily for general, high energy and radiation physicists, the systematic treatment adopted by the work makes it equally suitable as an advanced textbook for young researchers.

  11. X-ray fluorescence holography

    CERN Document Server

    Hayashi, K; Takahashi, Y

    2003-01-01

    X-ray fluorescence holography (XFH) is a new structural analysis method of determining a 3D atomic arrangement around fluorescing atoms. We developed an XFH apparatus using advanced X-ray techniques and succeeded in obtaining high-quality hologram data. Furthermore, we introduced applications to the structural analysis of a thin film and the environment around dopants and, discussed the quantitative analysis of local lattice distortion. (author)

  12. X-ray Sensitive Material

    Science.gov (United States)

    2015-12-01

    these published reports. There were two main types of X-ray detection methods: “indirect,” which uses a scintillation material coupled to a light...Reference 3), inorganic semiconductors (silicon [Si], cadmium zinc telluride [CdZnTe]) (Reference 4) and selenium (References 5 and 6), Ne-Xe...metal-oxide semiconductor field-effect transistor (MOSFET) X-ray dosimeters (Reference 24). Electrets may be charged by a range of methods

  13. X-ray laser; Roentgenlaser

    Energy Technology Data Exchange (ETDEWEB)

    Samuelsen, Emil J.; Breiby, Dag W.

    2009-07-01

    X-ray is among the most important research tools today, and has given priceless contributions to all disciplines within the natural sciences. State of the art in this field is called XFEL, X-ray Free Electron Laser, which may be 10 thousand million times stronger than the x-rays at the European Synchrotron Radiation Facility in Grenoble. In addition XFEL has properties that allow the study of processes which previously would have been impossible. Of special interest are depictions on atomic- and molecular level by the use of x-ray holographic methods, and being able to study chemical reactions in nature's own timescale, the femtosecond. Conclusion: The construction of x-ray lasers is a natural development in a scientific field which has an enormous influence on the surrounding society. While the discovery of x-ray was an important breakthrough in itself, new applications appear one after the other: Medical depiction, dissemination, diffraction, DNA and protein structures, synchrotron radiation and tomography. There is reason to believe that XFEL implies a technological leap as big as the synchrotrons some decades ago. As we are now talking about studies of femtosecond and direct depiction of chemical reactions, it is obvious that we are dealing with a revolution to come, with extensive consequences, both scientifically and culturally. (EW)

  14. X-Rays, Pregnancy and You

    Science.gov (United States)

    ... and Procedures Medical Imaging Medical X-ray Imaging X-Rays, Pregnancy and You Share Tweet Linkedin Pin ... the decision with your doctor. What Kind of X-Rays Can Affect the Unborn Child? During most ...

  15. A paediatric X-ray exposure chart

    Energy Technology Data Exchange (ETDEWEB)

    Knight, Stephen P, E-mail: stephen.knight@health.qld.gov.au [Department of Medical Imaging, Royal Children' s Hospital, Brisbane, Queensland (Australia)

    2014-09-15

    The aim of this review was to develop a radiographic optimisation strategy to make use of digital radiography (DR) and needle phosphor computerised radiography (CR) detectors, in order to lower radiation dose and improve image quality for paediatrics. This review was based on evidence-based practice, of which a component was a review of the relevant literature. The resulting exposure chart was developed with two distinct groups of exposure optimisation strategies – body exposures (for head, trunk, humerus, femur) and distal extremity exposures (elbow to finger, knee to toe). Exposure variables manipulated included kilovoltage peak (kVp), target detector exposure and milli-ampere-seconds (mAs), automatic exposure control (AEC), additional beam filtration, and use of antiscatter grid. Mean dose area product (DAP) reductions of up to 83% for anterior–posterior (AP)/posterior–anterior (PA) abdomen projections were recorded postoptimisation due to manipulation of multiple-exposure variables. For body exposures, the target EI and detector exposure, and thus the required mAs were typically 20% less postoptimisation. Image quality for some distal extremity exposures was improved by lowering kVp and increasing mAs around constant entrance skin dose. It is recommended that purchasing digital X-ray equipment with high detective quantum efficiency detectors, and then optimising the exposure chart for use with these detectors is of high importance for sites performing paediatric imaging. Multiple-exposure variables may need to be manipulated to achieve optimal outcomes.

  16. Compact x-ray lasers in the laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Barletta, W.A.

    1988-10-03

    Compact x-ray lasers in the laboratory can be produced with ultrahigh gradient rf linacs based on recent advances in linac technology by an SLAC-LLNL-LBL collaboration and on the development of bright, high current electron sources by BNL and LANL. The GeV electron beams generated with such accelerators can be converted to soft x rays in the range of 2--10 nm by passage through short period, high field strength wigglers. Alternatively, the beam can pump a low density dielectric to produce x rays via recombination. Such linear light sources can produce trains of picosecond (or shorter) pulses of extremely high spectral brilliance suitable for flash holography of biological specimens in vivo and for studies of fast chemical reactions. 15 refs., 7 figs., 3 tabs.

  17. Development of a flat-panel X-ray source

    Science.gov (United States)

    Grant, Edwin Joseph

    A novel flat-panel transmission type X-ray source was developed for both medical and industrial use. Depending on the geometry of the given situation, the flat-panel X-ray source could be used in tomography, radiography or tomosynthesis. Furthermore, the unit could be used as a portable X-ray scanner or an integral part of an existing detection system. The design incorporates a field emission cathode made of ultra-nanocrystalline diamonds (UNCD) doped with nitrogen. These field emitters show good electron output at low power and can be deposited over large areas as is the case with carbon nanotube "forest" (CNT) cathodes. This work presents the first generation of the UNCD based FEA prototype which was manufactured at the Center of Nanoscale Material, within Argonne National Laboratory, with standard microfabrication techniques. The prototype is a 3 x 3 pixel field emission array (FEA), with a pixel size of 225 mum by 225 mum and a pitch of 500 mum. The fabricated cathode was developed using a microfabrication process which allows for individual electrically addressable UNCD gated arrays on-chip which demonstrated monolithic integration of the electron extraction grid. The transmission target consists of tungsten for X-ray generation, which is sputtered directly upon a thin aluminum sheet as an X-ray filter. A low voltage power supply allows for electron extraction between the cathode and the grid; while a high voltage power supply accelerates the electrons towards the anode. A low energy X-ray high purity germanium detector (HPGe) is mounted outside of the vacuum chamber for X-ray detection and measurement.

  18. Supernova Properties from Shock Breakout X-rays

    CERN Document Server

    Calzavara, A

    2003-01-01

    We investigate the potential of the upcoming LOBSTER space observatory (due circa 2009) to detect soft X-ray flashes from shock breakout in supernoave, primarily from Type II events. LOBSTER should discover many SN breakout flashes, and will constrain the radii of their progenitor stars far more tightly than can be accomplished with optical observations of the SN light curve. We anticipate the appearance of blue supergiant explosions (SN 1987A analogs), allowing for the first time a snapshot of stellar evolution at the point of core collapse. We consider also how the mass, explosion energy, and absorbing column can be constrained from X-ray observables alone and with the assistance of optically-determined distances. These conclusions are drawn using known scaling relations to extrapolate, from previous numerical calculations, the LOBSTER response to explosions with a broad range of parameters.

  19. X-ray Echo Spectroscopy

    Science.gov (United States)

    Shvyd'ko, Yuri

    2016-02-01

    X-ray echo spectroscopy, a counterpart of neutron spin echo, is being introduced here to overcome limitations in spectral resolution and weak signals of the traditional inelastic x-ray scattering (IXS) probes. An image of a pointlike x-ray source is defocused by a dispersing system comprised of asymmetrically cut specially arranged Bragg diffracting crystals. The defocused image is refocused into a point (echo) in a time-reversal dispersing system. If the defocused beam is inelastically scattered from a sample, the echo signal acquires a spatial distribution, which is a map of the inelastic scattering spectrum. The spectral resolution of the echo spectroscopy does not rely on the monochromaticity of the x rays, ensuring strong signals along with a very high spectral resolution. Particular schemes of x-ray echo spectrometers for 0.1-0.02 meV ultrahigh-resolution IXS applications (resolving power >108 ) with broadband ≃5 - 13 meV dispersing systems are introduced featuring more than 103 signal enhancement. The technique is general, applicable in different photon frequency domains.

  20. X-ray echo spectroscopy

    CERN Document Server

    Shvyd'ko, Yuri

    2015-01-01

    X-ray echo spectroscopy, a counterpart of neutron spin-echo, is being introduced here to overcome limitations in spectral resolution and weak signals of the traditional inelastic x-ray scattering (IXS) probes. An image of a point-like x-ray source is defocused by a dispersing system comprised of asymmetrically cut specially arranged Bragg diffracting crystals. The defocused image is refocused into a point (echo) in a time-reversal dispersing system. If the defocused beam is inelastically scattered from a sample, the echo signal acquires a spatial distribution, which is a map of the inelastic scattering spectrum. The spectral resolution of the echo spectroscopy does not rely on the monochromaticity of the x-rays, ensuring strong signals along with a very high spectral resolution. Particular schemes of x-ray echo spectrometers for 0.1--0.02-meV ultra-high-resolution IXS applications (resolving power $> 10^8$) with broadband $\\simeq$~5--13~meV dispersing systems are introduced featuring more than $10^3$ signal e...

  1. X-ray Echo Spectroscopy.

    Science.gov (United States)

    Shvyd'ko, Yuri

    2016-02-26

    X-ray echo spectroscopy, a counterpart of neutron spin echo, is being introduced here to overcome limitations in spectral resolution and weak signals of the traditional inelastic x-ray scattering (IXS) probes. An image of a pointlike x-ray source is defocused by a dispersing system comprised of asymmetrically cut specially arranged Bragg diffracting crystals. The defocused image is refocused into a point (echo) in a time-reversal dispersing system. If the defocused beam is inelastically scattered from a sample, the echo signal acquires a spatial distribution, which is a map of the inelastic scattering spectrum. The spectral resolution of the echo spectroscopy does not rely on the monochromaticity of the x rays, ensuring strong signals along with a very high spectral resolution. Particular schemes of x-ray echo spectrometers for 0.1-0.02 meV ultrahigh-resolution IXS applications (resolving power >10^{8}) with broadband ≃5-13  meV dispersing systems are introduced featuring more than 10^{3} signal enhancement. The technique is general, applicable in different photon frequency domains.

  2. The effect of X-ray radiography exposure intensity on image quality of the monitor%X线曝光量对显示器影像质量的影响

    Institute of Scientific and Technical Information of China (English)

    曹允希; 刘慧琴; 邱建峰; 何乐民; 韩丰谈; 景学安

    2008-01-01

    目的 观察数字X线摄影(DR)系统不同曝光量与影像质量的关系.方法 选择摄影管电压90 kV、曝光量从0.5~16.0 mAs变化时,使用X线摄影系统对Cdrad 2.0对比度细节体模进行曝光,观察者对显示器的影像进行阅读,计算其影像质量因子(IQF).统计方法采用随机区组设计的方差分析(ANOVA),对8名检查者不同曝光量下测得IQF均值进行F检验,P<0.05为差异有统计学意义.结果 (1)管电压90 kV,曝光量从0.5~8.0 mAs变化时,随着曝光量的增大,观察者在显示器上观察到IQF逐渐减小,最小为38.54±2.82,曝光量从8.0~16.0 mAs变化时,IQF逐渐增大,最大为44.33±2.35.(2)不同曝光条件下,IQF差异有统计学意义(F=60.35,P<0.01).结论 随着X线摄影曝光量的增大,显示器图像分辨能力逐渐提高,摄影曝光量为8.0 mAs,影像质量最佳,曝光量>8.0 mAs,显示器对图像细节的显示能力开始下降.%Objective To explore the relationship between image quality and different exposure intensity of digital radiography(DR).Methods Using a contrast-detail phantom Cdrad 2.0,observers evaluated images on the monitots when exposure parameters were 90 kV and mAs ranged from 0.5 to 16.0 mAs.Then calculate image quality figure(IQF),and ANOVA was used to analyze the difference of IQF under different radiation dose in 8 subjects.Results (1)When exposure parameters were 90 kV and mAs altered from 0.5 to 8.0 mAs.the IQF observed on the monitor was reduced,and the minimal value was 38.54±2.82.When mAs changing from 8.0 to 16.0 mAs.IQF observed on the monitor was increased,and the maximum was 44.33±2.35.(2)Under the different exposure condition,the difference of IQF values were statistically significant(F=60.35,P<0.01).Conclusions With the increased exposure intensity,the image quality on monitor increased.When mAs was 8.0 mAs,image quality was the optimum When mAs was more than 8.0 mAs,the image quality on monitor reduced.

  3. Industrial radiographies

    CERN Multimedia

    2005-01-01

    The Radiation Protection group wishes to remind CERN staff responsible for contractors performing X-ray inspections on the CERN sites that the firms must apply the legislation in force in their country of origin, in particular with regard to the prevention of risks relating to ionizing radiation. Industrial radiography firms called on to work on the CERN sites must also comply with the rules laid down in CERN's Radiation Safety Manual and be registered in the relevant CERN database. Since CERN is responsible for safety on its own site, a number of additional rules have been laid down for this kind of work, as set out in Radiation Protection Procedure PRP30 https://edms.cern.ch/file/346848/LAST_RELEASED/PRP30.pdf The CERN Staff Member responsible for the contract shall register the company and issue notification that an X-ray inspection is to be performed via the web interface at the following address: http://cern.ch/rp-radio

  4. X-ray imaging: Perovskites target X-ray detection

    Science.gov (United States)

    Heiss, Wolfgang; Brabec, Christoph

    2016-05-01

    Single crystals of perovskites are currently of interest to help fathom fundamental physical parameters limiting the performance of perovskite-based polycrystalline solar cells. Now, such perovskites offer a technology platform for optoelectronic devices, such as cheap and sensitive X-ray detectors.

  5. Portable X-Ray Device

    Science.gov (United States)

    1983-01-01

    Portable x-ray instrument developed by NASA now being produced commercially as an industrial tool may soon find further utility as a medical system. The instrument is Lixiscope - Low Intensity X-Ray Imaging Scope -- a self-contained, battery-powered fluoroscope that produces an instant image through use of a small amount of radioactive isotope. Originally developed by Goddard Space Flight Center, Lixiscope is now being produced by Lixi, Inc. which has an exclusive NASA license for one version of the device.

  6. pyXSIM: Synthetic X-ray observations generator

    Science.gov (United States)

    ZuHone, John A.; Hallman, Eric. J.

    2016-08-01

    pyXSIM simulates X-ray observations from astrophysical sources. X-rays probe the high-energy universe, from hot galaxy clusters to compact objects such as neutron stars and black holes and many interesting sources in between. pyXSIM generates synthetic X-ray observations of these sources from a wide variety of models, whether from grid-based simulation codes such as FLASH (ascl:1010.082), Enzo (ascl:1010.072), and Athena (ascl:1010.014), to particle-based codes such as Gadget (ascl:0003.001) and AREPO, and even from datasets that have been created “by hand”, such as from NumPy arrays. pyXSIM can also manipulate the synthetic observations it produces in various ways and export the simulated X-ray events to other software packages to simulate the end products of specific X-ray observatories. pyXSIM is an implementation of the PHOX (ascl:1112.004) algorithm and was initially the photon_simulator analysis module in yt (ascl:1011.022); it is dependent on yt.

  7. Monte Carlo Simulation of Materials Under the Soil Diagnosed by X-ray Lateral Migration Radiography Method%X射线横向移动成像法识别土壤中物体的蒙特卡罗模拟

    Institute of Scientific and Technical Information of China (English)

    朱鹏飞; 叶雁; 朱巍; 李军; 罗振雄

    2011-01-01

    X射线横向移动成像是一种新的散射成像方法,直接利用大面积探测器分开探测单次和多次散射光子强度来识别被覆盖物体的组成类型、尺寸和浅表面缺陷等,法已被用于地雷探测.利用蒙特卡罗模拟软件MCNP5分别模拟了覆盖于土壤中的不同横向面积的铁、TNT以及含空气缺陷的TNT中X光子的散射过程.根据模拟结果分析了两类探测器上散射光子的强度与被测物等效原子序数和尺寸之间的关系,这些关系构成了利用X射线横向移动散射法识别物体的依据,初步给出了利用该方法识别土壤中物体需要满足的条件及其识别能力.%X -ray lateral migration radiography (LMR) is a new form of backscatter imaging that utilizes both multiple - scatter and single - scatter photons detected by large area detectors, which contain the information such as the shape and subsurface flaws of objects. The LMR method has been used to detect the landmine. MC-NP5 has been used to simulate X - ray photons scattering process in varying dimension of Fe ,TNT and TNT with air flaws from a LMR simulation setting. The relations between the scattering photons intensity and equivalent the atomic number as well as the dimension of objects were analyzed, and these relations are the foundation of the LMR methods. The condition and ability of materials under soil diagnosed by the LRM method are obtained.

  8. In-laboratory diffraction-enhanced X-ray imaging for articular cartilage.

    Science.gov (United States)

    Muehleman, Carol; Fogarty, Daniel; Reinhart, Benjamin; Tzvetkov, Tochko; Li, Jun; Nesch, Ivan

    2010-07-01

    The loss of articular cartilage characteristic of osteoarthritis can only be diagnosed by joint space narrowing when conventional radiography is used. This is due to the lack of X-ray contrast of soft tissues. Whereas conventional radiography harnesses the X-ray attenuation properties of tissues, Diffraction Enhanced Imaging (DEI), a novel radiographic technique, allows the visualization of soft tissues simultaneous with calcified tissues by virtue of its ability to not only harness X-ray attenuation but also the X-ray refraction from tissue boundaries. Previously, DEI was dependent upon synchrotron X-rays, but more recently, the development of nonsynchrotron DEI units has been explored. These developments serve to elaborate the full potential of radiography. Here, we tested the potential of an in-laboratory DEI system, called Diffraction-Enhanced X-ray Imaging (DEXI), to render images of articular cartilage displaying varying degrees of degradation, ex vivo. DEXI allowed visualization of even early stages of cartilage degeneration such as surface fibrillation. This may be of eventual clinical significance for the diagnosis of early stages of degeneration, or at the very least, to visualize soft tissue degeneration simultaneous with bone changes.

  9. X-rays and magnetism.

    Science.gov (United States)

    Fischer, Peter; Ohldag, Hendrik

    2015-09-01

    Magnetism is among the most active and attractive areas in modern solid state physics because of intriguing phenomena interesting to fundamental research and a manifold of technological applications. State-of-the-art synthesis of advanced magnetic materials, e.g. in hybrid structures paves the way to new functionalities. To characterize modern magnetic materials and the associated magnetic phenomena, polarized x-rays have emerged as unique probes due to their specific interaction with magnetic materials. A large variety of spectroscopic and microscopic techniques have been developed to quantify in an element, valence and site-sensitive way properties of ferro-, ferri-, and antiferromagnetic systems, such as spin and orbital moments, and to image nanoscale spin textures and their dynamics with sub-ns time and almost 10 nm spatial resolution. The enormous intensity of x-rays and their degree of coherence at next generation x-ray facilities will open the fsec time window to magnetic studies addressing fundamental time scales in magnetism with nanometer spatial resolution. This review will give an introduction into contemporary topics of nanoscale magnetic materials and provide an overview of analytical spectroscopy and microscopy tools based on x-ray dichroism effects. Selected examples of current research will demonstrate the potential and future directions of these techniques.

  10. X-Ray Diffractive Optics

    Science.gov (United States)

    Dennis, Brian; Li, Mary; Skinner, Gerald

    2013-01-01

    X-ray optics were fabricated with the capability of imaging solar x-ray sources with better than 0.1 arcsecond angular resolution, over an order of magnitude finer than is currently possible. Such images would provide a new window into the little-understood energy release and particle acceleration regions in solar flares. They constitute one of the most promising ways to probe these regions in the solar atmosphere with the sensitivity and angular resolution needed to better understand the physical processes involved. A circular slit structure with widths as fine as 0.85 micron etched in a silicon wafer 8 microns thick forms a phase zone plate version of a Fresnel lens capable of focusing approx. =.6 keV x-rays. The focal length of the 3-cm diameter lenses is 100 microns, and the angular resolution capability is better than 0.1 arcsecond. Such phase zone plates were fabricated in Goddard fs Detector Development Lab. (DDL) and tested at the Goddard 600-microns x-ray test facility. The test data verified that the desired angular resolution and throughput efficiency were achieved.

  11. Alpha proton x ray spectrometer

    Science.gov (United States)

    Rieder, Rudi; Waeke, H.; Economou, T.

    1994-01-01

    Mars Pathfinder will carry an alpha-proton x ray spectrometer (APX) for the determination of the elemental chemical composition of Martian rocks and soils. The instrument will measure the concentration of all major and some minor elements, including C, N, and O at levels above typically 1 percent.

  12. X-ray backscatter imaging

    Science.gov (United States)

    Dinca, Dan-Cristian; Schubert, Jeffrey R.; Callerame, J.

    2008-04-01

    In contrast to transmission X-ray imaging systems where inspected objects must pass between source and detector, Compton backscatter imaging allows both the illuminating source as well as the X-ray detector to be on the same side of the target object, enabling the inspection to occur rapidly and in a wide variety of space-constrained situations. A Compton backscatter image is similar to a photograph of the contents of a closed container, taken through the container walls, and highlights low atomic number materials such as explosives, drugs, and alcohol, which appear as especially bright objects by virtue of their scattering characteristics. Techniques for producing X-ray images based on Compton scattering will be discussed, along with examples of how these systems are used for both novel security applications and for the detection of contraband materials at ports and borders. Differences between transmission and backscatter images will also be highlighted. In addition, tradeoffs between Compton backscatter image quality and scan speed, effective penetration, and X-ray source specifications will be discussed.

  13. Stellar X-Ray Polarimetry

    Science.gov (United States)

    Swank, J.

    2011-01-01

    Most of the stellar end-state black holes, pulsars, and white dwarfs that are X-ray sources should have polarized X-ray fluxes. The degree will depend on the relative contributions of the unresolved structures. Fluxes from accretion disks and accretion disk corona may be polarized by scattering. Beams and jets may have contributions of polarized emission in strong magnetic fields. The Gravity and Extreme Magnetism Small Explorer (GEMS) will study the effects on polarization of strong gravity of black holes and strong magnetism of neutron stars. Some part of the flux from compact stars accreting from companion stars has been reflected from the companion, its wind, or accretion streams. Polarization of this component is a potential tool for studying the structure of the gas in these binary systems. Polarization due to scattering can also be present in X-ray emission from white dwarf binaries and binary normal stars such as RS CVn stars and colliding wind sources like Eta Car. Normal late type stars may have polarized flux from coronal flares. But X-ray polarization sensitivity is not at the level needed for single early type stars.

  14. High-Resolution X-ray Emission and X-ray Absorption Spectroscopy

    OpenAIRE

    de Groot, F. M. F.

    2001-01-01

    In this review, high-resolution X-ray emission and X-ray absorption spectroscopy will be discussed. The focus is on the 3d transition-metal systems. To understand high-resolution X-ray emission and reso-nant X-ray emission, it is first necessary to spend some time discussing the X-ray absorption process. Section II discusses 1s X-ray absorption, i.e., the K edges, and section III deals with 2p X-ray absorption, the L edges. X-ray emission is discussed in, respectively, the L edges. X-ray emis...

  15. Novelty detection of foreign objects in food using multi-modal X-ray imaging

    DEFF Research Database (Denmark)

    Einarsdottir, Hildur; Emerson, Monica Jane; Clemmensen, Line Katrine Harder

    2016-01-01

    In this paper we demonstrate a method for novelty detection of foreign objects in food products using grating-based multimodal X-ray imaging. With this imaging technique three modalities are available with pixel correspondence, enhancing organic materials such as wood chips, insects and soft...... plastics not detectable by conventional X-ray absorption radiography. We conduct experiments, where several food products are imaged with common foreign objects typically found in the food processing industry. To evaluate the benefit from using this multi-contrast X-ray technique over conventional X...

  16. Fabrication of applicator system of miniature X-ray tube based on carbon nanotubes for a skin cancer therapy

    Energy Technology Data Exchange (ETDEWEB)

    Park, Han Beom; Kim, Hyun Jin; Lee, Ju Hyuk; Ha, Jun Mok; Cho, Sung Oh [KAIST, Daejeon (Korea, Republic of)

    2016-05-15

    A miniature X-ray tube is a small X-ray generation device generally with a diameter of less than 10 mm. Because of the feasible installation in a spatially constrained area and the possibility of electrical on/off control, miniature X-ray tubes can be widely used for nondestructive X-ray radiography, hand held X-ray spectrometers, electric brachytherapy, and interstitial or intracavitary radiation therapy or imaging with the substitution of radioactive isotopes. Miniature X-ray tubes have been developed mostly using thermionic electron sources or secondary X-ray emission. The X-ray tube show excellent field emission properties and good X-ray spectrum. Also, the flattening filter was made to irradiate uniformly. The X-ray dose radial uniformities between installed flattening filter and non-installed flattening filter were measured. When flattening filter is equipped, X-ray uniformity was improved from higher than 20% to lower than 10%. As a result, the fabricated applicator system of the miniature X-ray tube using optimized flattening filter exhibited fairly excellent properties.

  17. High-Resolution X-ray Emission and X-ray Absorption Spectroscopy

    NARCIS (Netherlands)

    Groot, F.M.F. de

    2000-01-01

    In this review, high-resolution X-ray emission and X-ray absorption spectroscopy will be discussed. The focus is on the 3d transition-metal systems. To understand high-resolution X-ray emission and reso-nant X-ray emission, it is first necessary to spend some time discussing the X-ray absorption

  18. X-ray reprocessing in binaries

    Science.gov (United States)

    Paul, Biswajit

    2016-07-01

    We will discuss several aspects of X-ray reprocessing into X-rays or longer wavelength radiation in different kinds of binary systems. In high mass X-ray binaries, reprocessing of hard X-rays into emission lines or lower temperature black body emission is a useful tool to investigate the reprocessing media like the stellar wind, clumpy structures in the wind, accretion disk or accretion stream. In low mass X-ray binaries, reprocessing from the surface of the companion star, the accretion disk, warps and other structures in the accretion disk produce signatures in longer wavelength radiation. X-ray sources with temporal structures like the X-ray pulsars and thermonuclear burst sources are key in such studies. We will discuss results from several new investigations of X-ray reprocessing phenomena in X-ray binaries.

  19. Comparison of radiation doses between different modes of C-arm X-ray apparatus applied to lumbar nerve root canal radiography%不同模式下C形臂X射线机在腰椎神经根管造影术中产生的辐射剂量比较

    Institute of Scientific and Technical Information of China (English)

    伍亮; 张家立; 杨光; 莫怡; 付拴虎

    2015-01-01

    目的 对比C形臂X射线机脉冲透视和高对比度透视两种模式下术者在单节段腰椎神经根管造影术中所接受的有效辐射剂量,以探讨术中更为安全的C形臂X射线机透视模式. 方法 单节段腰椎管狭窄症患者46例,按随机数字表法分为A组24例、B组22例,分别在C形臂X射线机高对比度透视和脉冲透视模式下行腰椎神经根管造影,所有造影操作均由同一名医生完成. 记录造影术操作时间及使用C形臂X射线机的透视时间,测量施术者右手背、左前胸及颈部3个部位的有效辐射剂量. 结果 两组造影术平均操作时间及平均透视时间的比较,差异无统计学意义( P>0.05). A组术者右手背、左前胸及颈部平均有效辐射剂量分别为(0.142 ±0.012)mSv、(0.066 ±0.011)mSv、(0.031 ±0.005)mSv,B组术者右手背、左前胸及颈部平均有效辐射剂量分别为(0.102 ±0.009)mSv、(0.059 ±0.005)mSv、(0.030 ±0.004)mSv,其中B组术者右手背及左前胸的平均有效辐射剂量均低于A组(P0.05). 结论 在腰椎神经根管造影术中,脉冲透视模式对术者产生的辐射剂量低于高对比度透视模式,更为安全.%Objective To compare the effective radiation doses for operators during the single segmental lumbar nerve root canal radiography between pulsed fluoroscopy mode and high contrast fluoroscopy mode of C-arm X-ray apparatus so as to explore the safer fluoroscopy mode of C-arm X-ray apparatus during the operation.Methods Forty-six patients with single segmental lumbar spinal stenosis were randomly divided into Group A(n=24) and Group B(n=22).And the patients of group A and group B received lumbar nerve root canal radiography under high contrast fluoroscopy mode and pulse fluoroscopy mode of C-arm X-ray apparatus respectively.All cases were performed by the same operator.The operative time and fluoroscopy time were recorded,and the effective radiation doses of right opisthenar, left chest and

  20. Phase contrast imaging with coherent high energy X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Snigireva, I. [ESRF, Grenoble (France)

    1997-02-01

    X-ray imaging concern high energy domain (>6 keV) like a contact radiography, projection microscopy and tomography is used for many years to discern the features of the internal structure non destructively in material science, medicine and biology. In so doing the main contrast formation is absorption that makes some limitations for imaging of the light density materials and what is more the resolution of these techniques is not better than 10-100 {mu}m. It was turned out that there is now way in which to overcome 1{mu}m or even sub-{mu}m resolution limit except phase contrast imaging. It is well known in optics that the phase contrast is realised when interference between reference wave front and transmitted through the sample take place. Examples of this imaging are: phase contrast microscopy suggested by Zernike and Gabor (in-line) holography. Both of this techniques: phase contrast x-ray microscopy and holography are successfully progressing now in soft x-ray region. For imaging in the hard X-rays to enhance the contrast and to be able to resolve phase variations across the beam the high degree of the time and more importantly spatial coherence is needed. Because of this it was reasonable that the perfect crystal optics was involved like Bonse-Hart interferometry, double-crystal and even triple-crystal set-up using Laue and Bragg geometry with asymmetrically cut crystals.

  1. Structured illumination for tomographic X-ray diffraction imaging.

    Science.gov (United States)

    Greenberg, Joel A; Hassan, Mehadi; Krishnamurthy, Kalyani; Brady, David

    2014-02-21

    Tomographic imaging of the molecular structure of an object is important for a variety of applications, ranging from medical and industrial radiography to security screening. X-ray diffraction imaging is the preeminent technique for performing molecular analysis of large volumes. Here we propose and demonstrate a new measurement architecture to improve the source and detector efficiency for diffraction imaging. In comparison with previous techniques, our approach reduces the required overall scan time by 1-2 orders of magnitude, which makes possible real-time scanning of a broad range of materials over a large volume using a table-top setup. This method, which relies on structuring spatially the illumination incident on an object moving relative to the X-ray source, is compatible with existing systems and has the potential to significantly enhance performance in an array of areas, such as medical diagnostic imaging and explosives detection.

  2. X-Ray-powered Macronovae

    Science.gov (United States)

    Kisaka, Shota; Ioka, Kunihito; Nakar, Ehud

    2016-02-01

    A macronova (or kilonova) was observed as an infrared excess several days after the short gamma-ray burst GRB 130603B. Although the r-process radioactivity is widely discussed as an energy source, it requires a huge mass of ejecta from a neutron star (NS) binary merger. We propose a new model in which the X-ray excess gives rise to the simultaneously observed infrared excess via thermal re-emission, and explore what constraints this would place on the mass and velocity of the ejecta. This X-ray-powered model explains both the X-ray and infrared excesses with a single energy source such as the central engine like a black hole, and allows for a broader parameter region than the previous models, in particular a smaller ejecta mass ˜ {10}-3{--}{10}-2{M}⊙ and higher iron abundance mixed as suggested by general relativistic simulations for typical NS-NS mergers. We also discuss the other macronova candidates in GRB 060614 and GRB 080503, and the implications for the search of electromagnetic counterparts to gravitational waves.

  3. Be/X-ray binaries

    CERN Document Server

    Reig, Pablo

    2011-01-01

    The purpose of this work is to review the observational properties of Be/X-ray binaries. The open questions in Be/X-ray binaries include those related to the Be star companion, that is, the so-called "Be phenomenon", such as, timescales associated to the formation and dissipation of the equatorial disc, mass-ejection mechanisms, V/R variability, and rotation rates; those related to the neutron star, such as, mass determination, accretion physics, and spin period evolution; but also, those that result from the interaction of the two constituents, such as, disc truncation and mass transfer. Until recently, it was thought that the Be stars' disc was not significantly affected by the neutron star. In this review, I present the observational evidence accumulated in recent years on the interaction between the circumstellar disc and the compact companion. The most obvious effect is the tidal truncation of the disc. As a result, the equatorial discs in Be/X-ray binaries are smaller and denser than those around isolat...

  4. X-Ray Crystallography Reagent

    Science.gov (United States)

    Morrison, Dennis R. (Inventor); Mosier, Benjamin (Inventor)

    2003-01-01

    Microcapsules prepared by encapsulating an aqueous solution of a protein, drug or other bioactive substance inside a semi-permeable membrane by are disclosed. The microcapsules are formed by interfacial coacervation under conditions where the shear forces are limited to 0-100 dynes per square centimeter at the interface. By placing the microcapsules in a high osmotic dewatering solution. the protein solution is gradually made saturated and then supersaturated. and the controlled nucleation and crystallization of the protein is achieved. The crystal-filled microcapsules prepared by this method can be conveniently harvested and stored while keeping the encapsulated crystals in essentially pristine condition due to the rugged. protective membrane. Because the membrane components themselves are x-ray transparent, large crystal-containing microcapsules can be individually selected, mounted in x-ray capillary tubes and subjected to high energy x-ray diffraction studies to determine the 3-D smucture of the protein molecules. Certain embodiments of the microcapsules of the invention have composite polymeric outer membranes which are somewhat elastic, water insoluble, permeable only to water, salts, and low molecular weight molecules and are structurally stable in fluid shear forces typically encountered in the human vascular system.

  5. X-ray Radiography Measurements of Shear Coaxial Rocket Injectors

    Science.gov (United States)

    2013-05-07

    These injectors rely on the shear between an outer lower-density, high-velocity annulus and a higher-density, low-velocity inner jet to atomize and...velocities and the distance between radial points – Large uncertainty given the small distances, high velocities, and limited number of points

  6. MAXI observations of long X-ray bursts

    Science.gov (United States)

    Serino, Motoko; Iwakiri, Wataru; Tamagawa, Toru; Sakamoto, Takanori; Nakahira, Satoshi; Matsuoka, Masaru; Yamaoka, Kazutaka; Negoro, Hitoshi

    2016-12-01

    We report nine long X-ray bursts from neutron stars, detected with the Monitor of All-sky X-ray Image (MAXI). Some of these bursts lasted for hours, and hence are qualified as superbursts, which are prolonged thermonuclear flashes on neutron stars and are relatively rare events. MAXI observes roughly 85% of the whole sky every 92 minutes in the 2-20 keV energy band, and has detected nine bursts with a long e-folding decay time, ranging from 0.27 to 5.2 hr, since its launch in 2009 August until 2015 August. The majority of the nine events were found to originate from transient X-ray sources. The persistent luminosities of the sources, when these prolonged bursts were observed, were lower than 1% of the Eddington luminosity for five of them and lower than 20% for the rest. This trend is contrastive to the 18 superbursts observed before MAXI, all but two of which originated from bright persistent sources. The distribution of the total emitted energy, i.e., the product of e-folding time and luminosity, of these bursts clusters around 1041-1042 erg, whereas both the e-folding time and luminosity ranges for an order of magnitude. Among the nine events, two were from 4U 1850-086 during phases of relatively low persistent flux, whereas it usually exhibits standard short X-ray bursts during outbursts.

  7. X-Ray Exam: Scoliosis (For Parents)

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Scoliosis KidsHealth > For Parents > X-Ray Exam: Scoliosis A A A What's in ... español Radiografía: escoliosis What It Is A scoliosis X-ray is a relatively safe and painless test ...

  8. X-Ray Exam: Neck (For Parents)

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Neck KidsHealth > For Parents > X-Ray Exam: Neck A A A What's in ... español Radiografía: cuello What It Is A neck X-ray is a safe and painless test that ...

  9. X-Ray Exam: Femur (Upper Leg)

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Femur (Upper Leg) KidsHealth > For Parents > X-Ray Exam: Femur (Upper Leg) A A A ... español Radiografía: fémur What It Is A femur X-ray is a safe and painless test that ...

  10. Center for X-ray Optics, 1988

    Energy Technology Data Exchange (ETDEWEB)

    1989-04-01

    This report briefly reviews the following topics: soft-x-ray imaging; reflective optics for hard x-rays; coherent XUV sources; spectroscopy with x-rays; detectors for coronary artery imaging; synchrotron-radiation optics; and support for the advanced light source.

  11. Cryotomography x-ray microscopy state

    Science.gov (United States)

    Le Gros, Mark; Larabell, Carolyn A.

    2010-10-26

    An x-ray microscope stage enables alignment of a sample about a rotation axis to enable three dimensional tomographic imaging of the sample using an x-ray microscope. A heat exchanger assembly provides cooled gas to a sample during x-ray microscopic imaging.

  12. Chest X-ray patterns of pulmonary multidrug-resistant tuberculosis in ...

    African Journals Online (AJOL)

    2016-03-18

    Mar 18, 2016 ... 1Department of Radiology,. University of ... rifampicin, is a particular area of public health concern in South Africa, where the estimated. MDR-TB .... Frontal chest X-rays were acquired using digital radiography. (with Kodak ...

  13. 77 FR 27463 - Device Improvements for Pediatric X-Ray Imaging; Public Meeting; Request for Comments

    Science.gov (United States)

    2012-05-10

    ... instructions for pediatric digital radiography (Ref. 8) and fluoroscopy (ongoing project). These materials will... follows: ``Manufacturers seeking marketing clearance for a new x-ray imaging device with a pediatric.... Manufacturers who seek marketing clearance only for general indications or do not submit adequate data to...

  14. ASSESSMENT OF RESTORATION METHODS OF X-RAY IMAGES WITH EMPHASIS ON MEDICAL PHOTOGRAMMETRIC USAGE

    Directory of Open Access Journals (Sweden)

    S. Hosseinian

    2016-06-01

    Full Text Available Nowadays, various medical X-ray imaging methods such as digital radiography, computed tomography and fluoroscopy are used as important tools in diagnostic and operative processes especially in the computer and robotic assisted surgeries. The procedures of extracting information from these images require appropriate deblurring and denoising processes on the pre- and intra-operative images in order to obtain more accurate information. This issue becomes more considerable when the X-ray images are planned to be employed in the photogrammetric processes for 3D reconstruction from multi-view X-ray images since, accurate data should be extracted from images for 3D modelling and the quality of X-ray images affects directly on the results of the algorithms. For restoration of X-ray images, it is essential to consider the nature and characteristics of these kinds of images. X-ray images exhibit severe quantum noise due to limited X-ray photons involved. The assumptions of Gaussian modelling are not appropriate for photon-limited images such as X-ray images, because of the nature of signal-dependant quantum noise. These images are generally modelled by Poisson distribution which is the most common model for low-intensity imaging. In this paper, existing methods are evaluated. For this purpose, after demonstrating the properties of medical X-ray images, the more efficient and recommended methods for restoration of X-ray images would be described and assessed. After explaining these approaches, they are implemented on samples from different kinds of X-ray images. By considering the results, it is concluded that using PURE-LET, provides more effective and efficient denoising than other examined methods in this research.

  15. Assessment of Restoration Methods of X-Ray Images with Emphasis on Medical Photogrammetric Usage

    Science.gov (United States)

    Hosseinian, S.; Arefi, H.

    2016-06-01

    Nowadays, various medical X-ray imaging methods such as digital radiography, computed tomography and fluoroscopy are used as important tools in diagnostic and operative processes especially in the computer and robotic assisted surgeries. The procedures of extracting information from these images require appropriate deblurring and denoising processes on the pre- and intra-operative images in order to obtain more accurate information. This issue becomes more considerable when the X-ray images are planned to be employed in the photogrammetric processes for 3D reconstruction from multi-view X-ray images since, accurate data should be extracted from images for 3D modelling and the quality of X-ray images affects directly on the results of the algorithms. For restoration of X-ray images, it is essential to consider the nature and characteristics of these kinds of images. X-ray images exhibit severe quantum noise due to limited X-ray photons involved. The assumptions of Gaussian modelling are not appropriate for photon-limited images such as X-ray images, because of the nature of signal-dependant quantum noise. These images are generally modelled by Poisson distribution which is the most common model for low-intensity imaging. In this paper, existing methods are evaluated. For this purpose, after demonstrating the properties of medical X-ray images, the more efficient and recommended methods for restoration of X-ray images would be described and assessed. After explaining these approaches, they are implemented on samples from different kinds of X-ray images. By considering the results, it is concluded that using PURE-LET, provides more effective and efficient denoising than other examined methods in this research.

  16. X-ray phase scanning setup for non-destructive testing using Talbot-Lau interferometer

    Science.gov (United States)

    Bachche, S.; Nonoguchi, M.; Kato, K.; Kageyama, M.; Koike, T.; Kuribayashi, M.; Momose, A.

    2016-09-01

    X-ray grating interferometry has a great potential for X-ray phase imaging over conventional X-ray absorption imaging which does not provide significant contrast for weakly absorbing objects and soft biological tissues. X-ray Talbot and Talbot-Lau interferometers which are composed of transmission gratings and measure the differential X-ray phase shifts have gained popularity because they operate with polychromatic beams. In X-ray radiography, especially for nondestructive testing in industrial applications, the feasibility of continuous sample scanning is not yet completely revealed. A scanning setup is frequently advantageous when compared to a direct 2D static image acquisition in terms of field of view, exposure time, illuminating radiation, etc. This paper demonstrates an efficient scanning setup for grating-based Xray phase imaging using laboratory-based X-ray source. An apparatus consisting of an X-ray source that emits X-rays vertically, optical gratings and a photon-counting detector was used with which continuously moving objects across the field of view as that of conveyor belt system can be imaged. The imaging performance of phase scanner was tested by scanning a long continuous moving sample at a speed of 5 mm/s and absorption, differential-phase and visibility images were generated by processing non-uniform moire movie with our specially designed phase measurement algorithm. A brief discussion on the feasibility of phase scanner with scanning setup approach including X-ray phase imaging performance is reported. The successful results suggest a breakthrough for scanning objects those are moving continuously on conveyor belt system non-destructively using the scheme of X-ray phase imaging.

  17. The Enhanced Workflow and Efficiency of the Wireless Local Area Network (WLAN)-Based Direct Digital Radiography (DDR) Portable Radiography.

    Science.gov (United States)

    Ngan, Tsz-Lung; Wong, Edward Ting-Hei; Ng, Kris Lap-Shun; Jeor, Patrick Kwok-Shing; Lo, Gladys Goh

    2015-06-01

    With the implementation of the PACS in the hospital, there is an increasing demand from the clinicians for immediate access and display of radiological images. Recently, our hospital has installed the first wireless local area network (WLAN)-based direct digital radiography (DDR) portable radiography system. The DDR portable radiography system allows wireless retrieval of modality worklist and wireless transmission of portable X-ray image on the console to the Picture Archiving and Communication System (PACS), via WLAN connection of wireless fidelity (Wi-Fi). The aim of this study was to analyze the workflow and performance between the WLAN-based DDR portable radiography system and the old practice using conventional portable X-ray machine with computed radiography (CR) system. A total of 190 portable chest X-ray examinations were evaluated and timed, using the conventional portable X-ray machine with CR from March to April of 2012 and using the new DDR portable radiography system on December of 2012 (n = 97 for old system and n = 93 for DDR portable system). The time interval of image becoming available to the PACS using the WLAN-based DDR portable radiography system was significantly shorter than that of the old practice using the conventional portable X-ray machine with CR (6.8 ± 2.6 min for DDR portable system; 23 ± 10.2 min for old system; p DDR portable radiography system can enhance the workflow of portable radiography by reduction of procedural steps.

  18. Editorial: Focus on X-ray Beams with High Coherence

    Science.gov (United States)

    Robinson, Ian; Gruebel, Gerhard; Mochrie, Simon

    2010-03-01

    Williams, H M Quiney, A G Peele and K A Nugent Imaging of complex density in silver nanocubes by coherent x-ray diffraction R Harder, M Liang, Y Sun, Y Xia and I K Robinson Methodology for studying strain inhomogeneities in polycrystalline thin films during in situ thermal loading using coherent x-ray diffraction N Vaxelaire, H Proudhon, S Labat, C Kirchlechner, J Keckes, V Jacques, S Ravy, S Forest and O Thomas Ptychographic coherent diffractive imaging of weakly scattering specimens Martin Dierolf, Pierre Thibault, Andreas Menzel, Cameron M Kewish, Konstantins Jefimovs, Ilme Schlichting, Konstanze von König, Oliver Bunk and Franz Pfeiffer Dose requirements for resolving a given feature in an object by coherent x-ray diffraction imaging Andreas Schropp and Christian G Schroer FLASH: new opportunities for (time-resolved) coherent imaging of nanostructures R Treusch and J Feldhaus Structure of a single particle from scattering by many particles randomly oriented about an axis: toward structure solution without crystallization? D K Saldin, V L Shneerson, M R Howells, S Marchesini, H N Chapman, M Bogan, D Shapiro, R A Kirian, U Weierstall, K E Schmidt and J C H Spence Analysis of strain and stacking faults in single nanowires using Bragg coherent diffraction imaging V Favre-Nicolin, F Mastropietro, J Eymery, D Camacho, Y M Niquet, B M Borg, M E Messing, L-E Wernersson, R E Algra, E P A M Bakkers, T H Metzger, R Harder and I K Robinson Coherent science at the SwissFEL x-ray laser B D Patterson, R Abela, H-H Braun, U Flechsig, R Ganter, Y Kim, E Kirk, A Oppelt, M Pedrozzi, S Reiche, L Rivkin, Th Schmidt, B Schmitt, V N Strocov, S Tsujino and A F Wrulich Energy recovery linac (ERL) coherent hard x-ray sources Donald H Bilderback, Joel D Brock, Darren S Dale, Kenneth D Finkelstein, Mark A Pfeifer and Sol M Gruner Statistical and coherence properties of radiation from x-ray free-electron lasers E L Saldin, E A Schneidmiller and M V Yurkov Microscopic return point memory in Co

  19. X-Ray Visions of SS Cygni

    Science.gov (United States)

    Young, D. L.

    2004-12-01

    The Chandra X-Ray Observatory is the most sophisticated X-ray observatory launched by NASA. Chandra is designed to observe X-rays from highenergy regions of the universe, such as X-ray binary stars. On September 14, 2000, triggered by alerts from amateur astronomers worldwide, Chandra observed the outburst of the brightest northern dwarf nova SS Cygni. The cooperation of hundreds of amateur variable star astronomers and the Chandra X-Ray scientists and spacecraft specialists provided proof that the collaboration of amateur and professional astronomers is a powerful tool to study cosmic phenomena.

  20. X-ray Spectroscopy of Cooling Cluster

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, J.R.; /SLAC; Fabian, A.C.; /Cambridge U., Inst. of Astron.

    2006-01-17

    We review the X-ray spectra of the cores of clusters of galaxies. Recent high resolution X-ray spectroscopic observations have demonstrated a severe deficit of emission at the lowest X-ray temperatures as compared to that expected from simple radiative cooling models. The same observations have provided compelling evidence that the gas in the cores is cooling below half the maximum temperature. We review these results, discuss physical models of cooling clusters, and describe the X-ray instrumentation and analysis techniques used to make these observations. We discuss several viable mechanisms designed to cancel or distort the expected process of X-ray cluster cooling.

  1. Comets: mechanisms of x-ray activity

    Science.gov (United States)

    Ibadov, Subhon

    2016-07-01

    Basic mechanisms of X-ray activity of comets are considered, including D-D mechanism corresponding to generation of X-rays due to production of hot short-living plasma clumps at high-velocity collisions between cometary and interplanetary dust particles as well as M-M one corresponding to production of X-rays due to recombination of multicharge ions of solar wind plasma via charge exchange process at their collisions with molecules/atoms of the cometary atmospheres. Peculiarities of the variation of the comet X-ray spectrum and X-ray luminosity with variation of its heliocentric distance are revealed.

  2. An investigation of infection control for x-ray cassettes in a diagnostic imaging department

    Energy Technology Data Exchange (ETDEWEB)

    Fox, Matthew [School of Allied Health Professions and Science, Faculty of Health, Wellbeing and Science, University Campus Suffolk, Rope Walk, Ipswich, Suffolk, IP4 1LT (United Kingdom); Harvey, Jane M. [School of Allied Health Professions and Science, Faculty of Health, Wellbeing and Science, University Campus Suffolk, Rope Walk, Ipswich, Suffolk, IP4 1LT (United Kingdom)], E-mail: j.harvey@ucs.ac.uk

    2008-11-15

    Introduction: This research was conducted to investigate if X-ray cassettes could be a possible source of pathogens capable of causing nosocomial infections, and if they could be a possible vector for cross infection within the hospital environment. Method: The research involved the swabbing of X-ray cassettes in a Diagnostic Imaging Department of a large hospital in the east of England. Two areas of the Diagnostic Imaging Department were included in the study. Research concentrated on X-ray cassettes used for mobile radiography, accident and emergency and inpatient use. Forty cassettes were swabbed in total specifically for general levels of bacterial contamination, also for the presence or absence of methicillin-resistant Staphylococcus aureus (MRSA). A mapping exercise was completed following the location of an X-ray cassette typically used in mobile radiography. The exercise noted the level of direct contact with patient's skin and other possible routes of infection. Results: The results demonstrated that there were large levels of growth of samples taken from cassettes and developed in the Microbiology Department. Coagulase-negative Staphylococcus, Micrococci, Diptheroids and species of Bacillus were all identified. The mapping exercise in which the journey of a 35/43 cm cassette used for mobile radiography was tracked found that contact with patient's skin and potential pathogens or routes of cross infection was a common occurrence whilst undertaking mobile radiography. Conclusion: The research has identified the presence of bacterial contamination on cassettes. The research established that X-ray cassettes/imaging plates are often exposed to pathogens and possible routes of cross infection; also that patient's skin often comes directly in contact with the X-ray cassette/imaging plate. The research also shows that as cassettes/imaging plates are a potential source of cross infection, the Diagnostic Imaging Department may be partly responsible

  3. X-rays from solar system objects

    CERN Document Server

    Bhardwaj, Anil; Gladstone, G Randall; Cravens, Thomas E; Lisse, Carey M; Dennerl, Konrad; Branduardi-Raymont, Graziella; Wargelin, Bradford J; Waite, J Hunter; Robertson, Ina; Ostgaard, Nikolai; Beiersdorfer, Peter; Snowden, Steven L; Kharchenko, Vasili; 10.1016/j.pss.2006.11.009

    2010-01-01

    During the last few years our knowledge about the X-ray emission from bodies within the solar system has significantly improved. Several new solar system objects are now known to shine in X-rays at energies below 2 keV. Apart from the Sun, the known X-ray emitters now include planets (Venus, Earth, Mars, Jupiter, and Saturn), planetary satellites (Moon, Io, Europa, and Ganymede), all active comets, the Io plasma torus (IPT), the rings of Saturn, the coronae (exospheres) of Earth and Mars, and the heliosphere. The advent of higher-resolution X-ray spectroscopy with the Chandra and XMM-Newton X-ray observatories has been of great benefit in advancing the field of planetary X-ray astronomy. Progress in modeling X-ray emission, laboratory studies of X-ray production, and theoretical calculations of cross-sections, have all contributed to our understanding of processes that produce X-rays from the solar system bodies. At Jupiter and Earth, both auroral and non-auroral disk X-ray emissions have been observed. X-ray...

  4. Digital X-ray imager

    CERN Document Server

    LLNL &MedOptics Corporation

    1998-01-01

    The global objective of this cooperation was to lower the cost and improve the quality of breast health care in the United States. We planned to achieve it by designing a very high performance digital radiography unit for breast surgical specimen radiography in the operating room. These technical goals needed to be achieved at reasonable manufacturing costs to enable MedOptics to achieve high market penetration at a profit. Responsibility for overall project execution rested with MedOptics. MedOptics fabricated and demonstrated hardware, and selected components and handled the overall integration. After completion of this CRADA, MedOptics worked with collaborators to demonstrate clinical performance and utility. Finally, the company marketed the device. LLNL convened a multi-directorate expert panel for an intensive review of MedOptics point design. A written brief of panel conclusions and recommendations was prepared. In addition, LLNL was responsible for: computationally simulating the effects of varying so...

  5. Phase-contrast X-ray CT

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Atsushi [Hitachi Ltd., Hatoyama, Saitama (Japan). Advanced Research Lab.

    1996-08-01

    X-ray transmission imaging that creates image contrast from the distribution of the X-ray absorption coefficient is not sensitive to materials consisting of light elements such as hydrogen, carbon, nitrogen, and oxygen. On the other hand, the X-ray phase shift caused by the light elements is substantial enough to be detected even when absorption is almost zero. Hence, phase-contrast X-ray imaging is a promising technique for observing the structure inside biological soft tissues without the need for staining and without serious radiation exposure. Using fringe scanning X-ray interferometry, the X-ray phase shift caused by an object was measured. Three-dimensional image reconstruction of cancerous tissues using the measured phase shifts was enabled under tomographic configuration phase-contrast X-ray computed tomography (CT). (author)

  6. Full-field transmission x-ray imaging with confocal polycapillary x-ray optics.

    Science.gov (United States)

    Sun, Tianxi; Macdonald, C A

    2013-02-07

    A transmission x-ray imaging setup based on a confocal combination of a polycapillary focusing x-ray optic followed by a polycapillary collimating x-ray optic was designed and demonstrated to have good resolution, better than the unmagnified pixel size and unlimited by the x-ray tube spot size. This imaging setup has potential application in x-ray imaging for small samples, for example, for histology specimens.

  7. Spherical-Wave Far-Field Interferometer for Hard X-Ray Phase Contrast Imaging

    CERN Document Server

    Miao, Houxun; Harmon, Katherine J; Bennett, Eric E; Chedid, Nicholas; Panna, Alireza; Bhandarkar, Priya; Wen, Han

    2014-01-01

    Low dose, high contrast x-ray imaging is of general interest in medical diagnostic applications. X-ray Mach-Zehnder interferometers using collimated synchrotron beams demonstrate the highest levels of phase contrast under a given exposure dose. However, common x-ray sources emit divergent cone beams. Here, we developed a spherical-wave inline Mach-Zehnder interferometer for phase contrast imaging over an extended area with a broadband and divergent source. The first tabletop system was tested in imaging experiments of a mammographic accreditation phantom and various biological specimens. The noise level of the phase contrast images at a clinical radiation dose corresponded to a 6 nano radian bending of the x-ray wavefront. Un-resolved structures with conventional radiography and near-field interferometer techniques became visible at a fraction of the radiation dose.

  8. INTEGRAL monitoring of unusually long X-ray bursts

    DEFF Research Database (Denmark)

    of the known X-ray bursters are frequently observed by INTEGRAL, in particular in the frame of the Key Programmes. Taking advantage of the INTEGRAL instrumentation, an international collaboration led by the JEM-X team at the Danish National Space Institute has been monitoring the occurrence of uncommon burst...... be triggered by the helium flash. Half of the 15 intermediate long bursts known to date have been observed by INTEGRAL, and the mechanisms up to high energies of these unusual events have been investigated. Observation results will be presented that lead to an advanced description of the relationship between...

  9. EE technical review. Special issue: flash x-ray accelerator

    Energy Technology Data Exchange (ETDEWEB)

    1983-08-01

    Improvements to the pulsed power system of FXR made during the past year have resulted in much better reliability and repeatability. At a current level of 2.2 kA on target, the machine produces a radiation dose of 480 R at 1 m, with a spot size of 3 to 5 mm and with the dose repeatable within +- 10%. With this new capability, researchers have already begun to improve their understanding of material behavior at high pressure and densities, working in a heretofore inaccesible regime of radiographic penetration and resolution.

  10. X-Ray Attenuation Cell

    Energy Technology Data Exchange (ETDEWEB)

    Ryutov, D.; Toor, A.

    2000-03-03

    To minimize the pulse-to-pulse variation, the LCLS FEL must operate at saturation, i.e. 10 orders of magnitude brighter spectral brilliance than 3rd-generation light sources. At this intensity, ultra-high vacuums and windowless transport are required. Many of the experiments, however, will need to be conducted at a much lower intensity thereby requiring a reliable means to reduce the x-ray intensity by many orders of magnitude without increasing the pulse-to-pulse variation. In this report we consider a possible solution for controlled attenuation of the LCLS x-ray radiation. We suggest using for this purpose a windowless gas-filled cell with the differential pumping. Although this scheme is easily realizable in principle, it has to be demonstrated that the attenuator can be made short enough to be practical and that the gas loads delivered to the vacuum line of sight (LOS) are acceptable. We are not going to present a final, optimized design. Instead, we will provide a preliminary analysis showing that the whole concept is robust and is worth further study. The spatial structure of the LCLS x-ray pulse at the location of the attenuator is shown in Fig. 1. The central high-intensity component, due to the FEL, has a FWHM of {approx}100 {micro}m. A second component, due to the undulator's broad band spontaneous radiation is seen as a much lower intensity ''halo'' with a FWHM of 1 mm. We discuss two versions of the attenuation cell. The first is directed towards a controlled attenuation of the FEL up to the 4 orders of magnitude in the intensity, with the spontaneous radiation halo being eliminated by collimators. In the second version, the spontaneous radiation is not sacrificed but the FEL component (as well as the first harmonic of the spontaneous radiation) gets attenuated by a more modest factor up to 100. We will make all the estimates assuming that the gas used in the attenuator is Xenon and that the energy of the FEL is 8.25 keV. At

  11. Soft x-ray scattering using FEL radiation for probing near-solid density plasmas at few electronvolt temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Toleikis, S; Faustlin, R R; Cao, L; Doppner, T; Dusterer, S; Forster, E; Fortmann, C; Glenzer, S H; Gode, S; Gregori, G; Irsig, R; Laarmann, T; Lee, H J; Li, B; Meiwes-Broer, K; Przystawik, A; Radcliffe, P; Redmer, R; Tavella, F; Thiele, R; Tiggesbaumker, J; Truong, N X; Uschmann, I; Zastrau, U; Tschentscher, T

    2009-03-03

    We report on soft x-ray scattering experiments on cryogenic hydrogen and simple metal targets. As a source of intense and ultrashort soft x-ray pulses we have used free-electron laser radiation at 92 eV photon energy from FLASH at DESY, Hamburg. X-ray pulses with energies up to 100 {micro}J and durations below 50 fs provide interaction with the target leading simultaneously to plasma formation and scattering. Experiments exploiting both of these interactions have been carried out, using the same experimental setup. Firstly, recording of soft x-ray inelastic scattering from near-solid density hydrogen plasmas at few electronvolt temperatures confirms the feasibility of this diagnostics technique. Secondly, the soft x-ray excitation of few electronvolt solid-density plasmas in simple metals could be studied by recording soft x-ray line and continuum emission integrated over emission times from fs to ns.

  12. Controlling X-rays With Light

    Energy Technology Data Exchange (ETDEWEB)

    Glover, Ernie; Hertlein, Marcus; Southworth, Steve; Allison, Tom; van Tilborg, Jeroen; Kanter, Elliot; Krassig, B.; Varma, H.; Rude, Bruce; Santra, Robin; Belkacem, Ali; Young, Linda

    2010-08-02

    Ultrafast x-ray science is an exciting frontier that promises the visualization of electronic, atomic and molecular dynamics on atomic time and length scales. A largelyunexplored area of ultrafast x-ray science is the use of light to control how x-rays interact with matter. In order to extend control concepts established for long wavelengthprobes to the x-ray regime, the optical control field must drive a coherent electronic response on a timescale comparable to femtosecond core-hole lifetimes. An intense field is required to achieve this rapid response. Here an intense optical control pulse isobserved to efficiently modulate photoelectric absorption for x-rays and to create an ultrafast transparency window. We demonstrate an application of x-ray transparencyrelevant to ultrafast x-ray sources: an all-photonic temporal cross-correlation measurement of a femtosecond x-ray pulse. The ability to control x-ray/matterinteractions with light will create new opportunities at current and next-generation x-ray light sources.

  13. Qualitative comparison of bremsstrahlung X-rays and 800 MeV protons for tomography of urania fuel pellets.

    Science.gov (United States)

    Morris, C L; Bourke, M; Byler, D D; Chen, C F; Hogan, G; Hunter, J F; Kwiatkowski, K; Mariam, F G; McClellan, K J; Merrill, F; Morley, D J; Saunders, A

    2013-02-01

    We present an assessment of x-rays and proton tomography as tools for studying the time dependence of the development of damage in fuel rods. We also show data taken with existing facilities at Los Alamos National Laboratory that support this assessment. Data on surrogate fuel rods have been taken using the 800 MeV proton radiography (pRad) facility at the Los Alamos Neutron Science Center (LANSCE), and with a 450 keV bremsstrahlung X-ray tomography facility. The proton radiography pRad facility at LANSCE can provide good position resolution (<70 μm has been demonstrate, 20 μm seems feasible with minor changes) for tomography on activated fuel rods. Bremsstrahlung x-rays may be able to provide better than 100 μm resolution but further development of sources, collimation, and detectors is necessary for x-rays to deal with the background radiation for tomography of activated fuel rods.

  14. X-Ray Radiographic Observation of Directional Solidification Under Microgravity: XRMON-GF Experiments on MASER12 Sounding Rocket Mission

    Science.gov (United States)

    Reinhart, G.; NguyenThi, H.; Bogno, A.; Billia, B.; Houltz, Y.; Loth, K.; Voss, D.; Verga, A.; dePascale, F.; Mathiesen, R. H.; Zimmermann, G.

    2012-01-01

    The European Space Agency (ESA) - Microgravity Application Promotion (MAP) programme entitled XRMON (In situ X-Ray MONitoring of advanced metallurgical processes under microgravity and terrestrial conditions) aims to develop and perform in situ X-ray radiography observations of metallurgical processes in microgravity and terrestrial environments. The use of X-ray imaging methods makes it possible to study alloy solidification processes with spatio-temporal resolutions at the scales of relevance for microstructure formation. XRMON has been selected for MASER 12 sounding rocket experiment, scheduled in autumn 2011. Although the microgravity duration is typically six minutes, this short time is sufficient to investigate a solidification experiment with X-ray radiography. This communication will report on the preliminary results obtained with the experimental set-up developed by SSC (Swedish Space Corporation). Presented results dealing with directional solidification of Al-Cu confirm the great interest of performing in situ characterization to analyse dynamical phenomena during solidification processes.

  15. Qualitative comparison of bremsstrahlung X-rays and 800 MeV protons for tomography of urania fuel pellets

    Energy Technology Data Exchange (ETDEWEB)

    Morris, C. L.; Bourke, M.; Byler, D. D.; Chen, C. F.; Hogan, G.; Hunter, J. F.; Kwiatkowski, K.; Mariam, F. G.; McClellan, K. J.; Merrill, F.; Morley, D. J.; Saunders, A. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States)

    2013-02-15

    We present an assessment of x-rays and proton tomography as tools for studying the time dependence of the development of damage in fuel rods. We also show data taken with existing facilities at Los Alamos National Laboratory that support this assessment. Data on surrogate fuel rods have been taken using the 800 MeV proton radiography (pRad) facility at the Los Alamos Neutron Science Center (LANSCE), and with a 450 keV bremsstrahlung X-ray tomography facility. The proton radiography pRad facility at LANSCE can provide good position resolution (<70 {mu}m has been demonstrate, 20 {mu}m seems feasible with minor changes) for tomography on activated fuel rods. Bremsstrahlung x-rays may be able to provide better than 100 {mu}m resolution but further development of sources, collimation, and detectors is necessary for x-rays to deal with the background radiation for tomography of activated fuel rods.

  16. Diffractive X-Ray Telescopes

    Science.gov (United States)

    Skinner, Gerald K.

    2010-01-01

    Diffractive X-ray telescopes, using zone plates, phase Fresnel lenses, or related optical elements have the potential to provide astronomers with true imaging capability with resolution many orders of magnitude better than available in any other waveband. Lenses that would be relatively easy to fabricate could have an angular resolution of the order of micro-arc-seconds or even better, that would allow, for example, imaging of the distorted spacetime in the immediate vicinity of the super-massive black holes in the center of active galaxies. What then is precluding their immediate adoption? Extremely long focal lengths, very limited bandwidth, and difficulty stabilizing the image are the main problems. The history, and status of the development of such lenses is reviewed here and the prospects for managing the challenges that they present are discussed.

  17. Diffractive X-ray Telescopes

    CERN Document Server

    Skinner, Gerald K

    2010-01-01

    Diffractive X-ray telescopes using zone plates, phase Fresnel lenses, or related optical elements have the potential to provide astronomers with true imaging capability with resolution several orders of magnitude better than available in any other waveband. Lenses that would be relatively easy to fabricate could have an angular resolution of the order of micro-arc-seconds or even better, that would allow, for example, imaging of the distorted space- time in the immediate vicinity of the super-massive black holes in the center of active galaxies What then is precluding their immediate adoption? Extremely long focal lengths, very limited bandwidth, and difficulty stabilizing the image are the main problems. The history, and status of the development of such lenses is reviewed here and the prospects for managing the challenges that they present are discussed.

  18. Digital chest radiography: collimation and dose reduction

    DEFF Research Database (Denmark)

    Debess, Jeanne; Johnsen, Karen Kirstine; Vejle-Sørensen, Jens Kristian

    Purpose: Quality improvement of basic radiography focusing on collimation and dose reduction in digital chest radiography Methods and Materials:A retrospective study of digital chest radiography is performed to evaluate the primary x-ray tube collimation of the PA and lateral radiographs. Data from...... of clinical supervisors. Optimal collimation is determined by European and Regional Danish guidelines. The areal between current and optimal collimation is calculated. The experimental research is performed in September - October 2014 Siemens Axiom Aristos digital radiography system DR using 150 kV, 1,25 -3...

  19. Radiography at CERN

    CERN Document Server

    HSE Unit

    2014-01-01

    What is industrial radiography? It is a non-destructive method with a wide variety of applications, such as inspecting the quality of a weld. It uses high-energy radioactive sources or an X-ray generator.   Is this inspection technique used at CERN? Yes, it is widely used at CERN by the EN-MME Group, which outsources the work to one or more companies, depending on the workload. Is it possible to carry out radiography anywhere at CERN? Yes, it is possible to carry out radiography in any building/accelerator/experiment area at CERN (including in areas which are not normally subject to radiological hazards). When is radiography carried out? It normally takes place outside of working hours (7 p.m. to 6 a.m.). How will I know if radiography is taking place in my building? If this activity is planned in a CERN building, notices will be affixed to all of its main entrance doors at least 24 hours in advance. What are the risks? There is a risk of exposure to very high levels of radiation, dep...

  20. Metrological aspects of the dosimetry in X-ray diagnostics; Metrologische Aspekte der Dosimetrie in der Roentgendiagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Bueermann, Ludwig [Physikalisch-Technische Bundesanstalt (PTB), Braunschweig (Germany). Arbeitsgruppe ' Dosimetrie fuer die Roentgendiagnostik'

    2013-06-15

    The author describes the evaluation methods in dosimetry with special regards to the air kerma. Furthermore application-specific quantities in radiography, mammography, and computer tomography are described. Then quality assurance in X-ray diagnostics and the determination of the organ dosis and the effective patient dosis are described. Finally the requirements on the uncertainties of dose measurements in X-ray diagnostics are considered. (HSI)

  1. Handbook of X-Ray Data

    CERN Document Server

    Zschornack, Günter

    2007-01-01

    This sourcebook is intended as an X-ray data reference for scientists and engineers working in the field of energy or wavelength dispersive X-ray spectrometry and related fields of basic and applied research, technology, or process and quality controlling. In a concise and informative manner, the most important data connected with the emission of characteristic X-ray lines are tabulated for all elements up to Z = 95 (Americium). This includes X-ray energies, emission rates and widths as well as level characteristics such as binding energies, fluorescence yields, level widths and absorption edges. The tabulated data are characterized and, in most cases, evaluated. Furthermore, all important processes and phenomena connected with the production, emission and detection of characteristic X-rays are discussed. This reference book addresses all researchers and practitioners working with X-ray radiation and fills a gap in the available literature.

  2. Absorbed radiation by various tissues during simulated endodontic radiography

    Energy Technology Data Exchange (ETDEWEB)

    Torabinejad, M.; Danforth, R.; Andrews, K.; Chan, C.

    1989-06-01

    The amount of absorbed radiation by various organs was determined by placing lithium fluoride thermoluminescent chip dosimeters at selected anatomical sites in and on a human-like X-ray phantom and exposing them to radiation at 70- and 90-kV X-ray peaks during simulated endodontic radiography. The mean exposure dose was determined for each anatomical site. The results show that endodontic X-ray doses received by patients are low when compared with other radiographic procedures.

  3. X-ray data booklet. Revision

    Energy Technology Data Exchange (ETDEWEB)

    Vaughan, D. (ed.)

    1986-04-01

    A compilation of data is presented. Included are properties of the elements, electron binding energies, characteristic x-ray energies, fluorescence yields for K and L shells, Auger energies, energy levels for hydrogen-, helium-, and neonlike ions, scattering factors and mass absorption coefficients, and transmission bands of selected filters. Also included are selected reprints on scattering processes, x-ray sources, optics, x-ray detectors, and synchrotron radiation facilities. (WRF)

  4. X-ray generation using carbon nanotubes

    OpenAIRE

    Parmee, Richard J.; Collins, Clare M.; William I. Milne; Cole, Matthew T.

    2015-01-01

    This is the final published version. It first appeared at http://www.nanoconvergencejournal.com/content/2/1/1. Since the discovery of X-rays over a century ago the techniques applied to the engineering of X-ray sources have remained relatively unchanged. From the inception of thermionic electron sources, which, due to simplicity of fabrication, remain central to almost all X-ray applications, there have been few fundamental technological advances. However, with the emergence of ever more d...

  5. Applications of soft x-ray lasers

    Energy Technology Data Exchange (ETDEWEB)

    Skinner, C.H.

    1993-08-01

    The high brightness and short pulse duration of soft x-ray lasers provide unique advantages for novel applications. Imaging of biological specimens using x-ray lasers has been demonstrated by several groups. Other applications to fields such as chemistry, material science, plasma diagnostics, and lithography are beginning to emerge. We review the current status of soft x-ray lasers from the perspective of applications, and present an overview of the applications currently being developed.

  6. Topological X-Rays and MRIs

    Science.gov (United States)

    Lynch, Mark

    2002-01-01

    Let K be a compact subset of the interior of the unit disk D in the plane and suppose one can't see through the boundary of D and identify K. However, assume that one can take "topological X-rays" of D which measure the "density" of K along the lines of the X-rays. By taking these X-rays from all directions, a "topological MRI" is generated for…

  7. Incidental findings in chest X-rays; Zufallsbefunde im Roentgenthorax

    Energy Technology Data Exchange (ETDEWEB)

    Wielpuetz, M.O.; Kauczor, H.U. [Universitaetsklinikum Heidelberg, Klinik fuer Diagnostische und Interventionelle Radiologie, Heidelberg (Germany); Universitaet Heidelberg, Translational Lung Research Center (TLRC), Deutsches Zentrum fuer Lungenforschung (DZL), Heidelberg (Germany); Universitaetsklinikum Heidelberg, Klinik fuer Diagnostische und Interventionelle Radiologie mit Nuklearmedizin, Thoraxklinik, Heidelberg (Germany); Weckbach, S. [Universitaetsklinikum Heidelberg, Klinik fuer Diagnostische und Interventionelle Radiologie, Heidelberg (Germany); Universitaet Heidelberg, Translational Lung Research Center (TLRC), Deutsches Zentrum fuer Lungenforschung (DZL), Heidelberg (Germany)

    2017-04-15

    Conventional projection radiography (chest x-ray) is one of the most frequently requested procedures in radiology. Even though chest x-ray imaging is frequently performed in asymptomatic patients for preoperative assessment, clinically relevant incidental findings are relatively scarce. This is due to the relatively low sensitivity of chest x-rays where few clinically relevant incidental findings are to be expected, as any detectable pathologies will as a rule already be clinically symptomatic. Recommendations from relevant societies for the management of incidental findings, apart from the clarification of incidental nodules, do not exist. This review article therefore describes the most frequent and typical incidental findings of lung parenchyma (apart from pulmonary nodules), mediastinal structures including the hilum of the lungs, pleura, chest wall and major vessels. Also described are those findings which can be diagnosed with sufficient certainty from chest x-rays so that further clarification is not necessary and those which must be further clarified by multislice imaging procedures or other techniques. (orig.) [German] Eine der haeufigsten Untersuchungen in der Radiologie ist die konventionelle Projektionsradiographie des Thorax (Roentgenthorax). Auch wenn projektionsradiographische Aufnahmen im Rahmen einer praeoperativen Abklaerung haeufig als orientierende Untersuchung angefertigt werden, sind - bedingt durch die relativ geringe Sensitivitaet des Roentgenthorax - wenig klinisch relevante Zufallsbefunde zu erwarten, da nachweisbare Pathologien in der Regel bereits auch klinisch apparent sind. Empfehlungen entsprechender Fachgesellschaften zu Zufallsbefunden im Roentgenthorax jenseits der Abklaerung von Rundherden liegen nicht vor. Die vorliegende Arbeit beleuchtet daher haeufige und typische Zufallsbefunde des Lungenparenchyms (ausser den Lungenrundherden), der mediastinalen Strukturen einschliesslich der Hili, der Pleura, der Thoraxwand sowie der

  8. Observation of femtosecond X-ray interactions with matter using an X-ray-X-ray pump-probe scheme.

    Science.gov (United States)

    Inoue, Ichiro; Inubushi, Yuichi; Sato, Takahiro; Tono, Kensuke; Katayama, Tetsuo; Kameshima, Takashi; Ogawa, Kanade; Togashi, Tadashi; Owada, Shigeki; Amemiya, Yoshiyuki; Tanaka, Takashi; Hara, Toru; Yabashi, Makina

    2016-02-01

    Resolution in the X-ray structure determination of noncrystalline samples has been limited to several tens of nanometers, because deep X-ray irradiation required for enhanced resolution causes radiation damage to samples. However, theoretical studies predict that the femtosecond (fs) durations of X-ray free-electron laser (XFEL) pulses make it possible to record scattering signals before the initiation of X-ray damage processes; thus, an ultraintense X-ray beam can be used beyond the conventional limit of radiation dose. Here, we verify this scenario by directly observing femtosecond X-ray damage processes in diamond irradiated with extraordinarily intense (∼10(19) W/cm(2)) XFEL pulses. An X-ray pump-probe diffraction scheme was developed in this study; tightly focused double-5-fs XFEL pulses with time separations ranging from sub-fs to 80 fs were used to excite (i.e., pump) the diamond and characterize (i.e., probe) the temporal changes of the crystalline structures through Bragg reflection. It was found that the pump and probe diffraction intensities remain almost constant for shorter time separations of the double pulse, whereas the probe diffraction intensities decreased after 20 fs following pump pulse irradiation due to the X-ray-induced atomic displacement. This result indicates that sub-10-fs XFEL pulses enable conductions of damageless structural determinations and supports the validity of the theoretical predictions of ultraintense X-ray-matter interactions. The X-ray pump-probe scheme demonstrated here would be effective for understanding ultraintense X-ray-matter interactions, which will greatly stimulate advanced XFEL applications, such as atomic structure determination of a single molecule and generation of exotic matters with high energy densities.

  9. Phase-contrast X-ray CT

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Atsushi [Hitachi Ltd., Saitama (Japan). Advanced Research Laboratory; Takeda, Tohoru; Itai, Yuji

    1995-12-01

    Phase-contrast X-ray computed tomography (CT) enabling the observation of biological soft tissues without contrast enhancement has been developed. The X-ray phase shift caused by an object is measured and input to a standard CT reconstruction algorithm. A thousand times increase in the image sensitivity to soft tissues is achieved compared with the conventional CT using absorption contrast. This is because the X-ray phase shift cross section of light elements is about a thousand times larger than the absorption cross section. The phase shift is detected using an X-ray interferometer and computer analyses of interference patterns. Experiments were performed using a synchrotron X-ray source. Excellent image sensitivity is demonstrated in the observation of cancerous rabbit liver. The CT images distinguish cancer lesion from normal liver tissue and, moreover, visualize the pathological condition in the lesion. Although the X-ray energy employed and the present observation area size are not suitable for medical applications as they are, phase-contrast X-ray CT is promising for investigating the internal structure of soft tissue which is almost transparent for X-rays. The high sensitivity also provides the advantage of reducing X-ray doses. (author).

  10. An Imaging X-Ray Polarimetry Mission

    Science.gov (United States)

    Weisskopf, Martin C.; Bellazini, Ronaldo; Costa, Enrico; Ramsey, Brian; O'Dell, Steve; Elsner, Ronald; Pavlov, George; Matt, Giorgio; Kaspi, Victoria; Tennant, Allyn; Coppi, Paolo; Wu, Kinwah; Siegmund, Oswald

    2008-01-01

    Technical progress both in x-ray optics and in polarization-sensitive x-ray detectors, which our groups have pioneered, enables a scientifically powerful---yet inexpensive---dedicated mission for imaging x-ray polarimetry. Such a mission is sufficiently sensitive to measure x-ray (linear) polarization for a broad range of cosmic sources --particularly those involving neutron stars, stellar black holes, and supermassive black holes (active galactic nuclei). We describe the technical elements, discuss a mission concept, and synopsize the important physical and astrophysical questions such a mission would address.

  11. The efficacy of x-ray pelvimetry

    Energy Technology Data Exchange (ETDEWEB)

    Barton, J.J. (Univ. of Illinois, Chicago); Garbaciak, J.A. Jr.; Ryan, G.M., Jr.

    1982-06-01

    Comparison is made of x-ray pelvimetry use on a public and private service in 1974 with experience in 1979, when the clinic service did no x-ray pelvimetry while the private service continued as before. It is concluded that the use of x-ray pelvimetry is inadequate as a predictor of cesarean section because of cephalopelvic disproportion, does not improve neonatal mortality, and poses potential hazards to the mother and fetus. Its use in the management of breech presentations is not currently established by our data. Guidelines are presented for the management of patients in labor without using x-ray pelvimetry.

  12. Symbiotic Stars in X-rays

    Science.gov (United States)

    Luna, G. J. M.; Sokoloski, J. L.; Mukai, K.; Nelson, T.

    2014-01-01

    Until recently, symbiotic binary systems in which a white dwarf accretes from a red giant were thought to be mainly a soft X-ray population. Here we describe the detection with the X-ray Telescope (XRT) on the Swift satellite of 9 white dwarf symbiotics that were not previously known to be X-ray sources and one that was previously detected as a supersoft X-ray source. The 9 new X-ray detections were the result of a survey of 41 symbiotic stars, and they increase the number of symbiotic stars known to be X-ray sources by approximately 30%. Swift/XRT detected all of the new X-ray sources at energies greater than 2 keV. Their X-ray spectra are consistent with thermal emission and fall naturally into three distinct groups. The first group contains those sources with a single, highly absorbed hard component, which we identify as probably coming from an accretion-disk boundary layer. The second group is composed of those sources with a single, soft X-ray spectral component, which likely arises in a region where low-velocity shocks produce X-ray emission, i.e. a colliding-wind region. The third group consists of those sources with both hard and soft X-ray spectral components. We also find that unlike in the optical, where rapid, stochastic brightness variations from the accretion disk typically are not seen, detectable UV flickering is a common property of symbiotic stars. Supporting our physical interpretation of the two X-ray spectral components, simultaneous Swift UV photometry shows that symbiotic stars with harder X-ray emission tend to have stronger UV flickering, which is usually associated with accretion through a disk. To place these new observations in the context of previous work on X-ray emission from symbiotic stars, we modified and extended the alpha/beta/gamma classification scheme for symbiotic-star X-ray spectra that was introduced by Muerset et al. based upon observations with the ROSAT satellite, to include a new sigma classification for sources with

  13. Ultrashort X-ray pulse science

    Energy Technology Data Exchange (ETDEWEB)

    Chin, Alan Hap [Univ. of California, Berkeley, CA (US). Dept. of Physics; Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    1998-05-01

    A variety of phenomena involves atomic motion on the femtosecond time-scale. These phenomena have been studied using ultrashort optical pulses, which indirectly probe atomic positions through changes in optical properties. Because x-rays can more directly probe atomic positions, ultrashort x-ray pulses are better suited for the study of ultrafast structural dynamics. One approach towards generating ultrashort x-ray pulses is by 90° Thomson scattering between terawatt laser pulses and relativistic electrons. Using this technique, the author generated ~ 300 fs, 30 keV (0.4 Å) x-ray pulses. These x-ray pulses are absolutely synchronized with ultrashort laser pulses, allowing femtosecond optical pump/x-ray probe experiments to be performed. Using the right-angle Thomson scattering x-ray source, the author performed time-resolved x-ray diffraction studies of laser-perturbated InSb. These experiments revealed a delayed onset of lattice expansion. This delay is due to the energy relaxation from a dense electron-hole plasma to the lattice. The dense electron-hole plasma first undergoes Auger recombination, which reduces the carrier concentration while maintaining energy content. Longitudinal-optic (LO) phonon emission then couples energy to the lattice. LO phonon decay into acoustic phonons, and acoustic phonon propagation then causes the growth of a thermally expanded layer. Source characterization is instrumental in utilizing ultrashort x-ray pulses in time-resolved x-ray spectroscopies. By measurement of the electron beam diameter at the generation point, the pulse duration of the Thomson scattered x-rays is determined. Analysis of the Thomson scattered x-ray beam properties also provides a novel means of electron bunch characterization. Although the pulse duration is inferred for the Thomson scattering x-ray source, direct measurement is required for other x-ray pulse sources. A method based on the laser-assisted photoelectric effect (LAPE) has been demonstrated as a

  14. Hard X-ray Modulation Telescope

    Institute of Scientific and Technical Information of China (English)

    LU Fangjun

    2011-01-01

    The Hard X-ray Modulation Telescope (HXMT) will be China's first astronomical satellite. On board HXMT there are three kinds of slat-collimated telescopes, the High Energy X-ray Telescope (HE, 20-250 keV, 5000 cm^2), the Medium Energy X-ray Telescope (ME, 5-30 keV, 952 cm^2), and the Low Energy X-ray Telescope (LE, 1-15 keV, 384 cm^2).

  15. Ultrashort X-ray pulse science

    Energy Technology Data Exchange (ETDEWEB)

    Chin, Alan Hap [Univ. of California, Berkeley, CA (US). Dept. of Physics; Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    1998-05-01

    A variety of phenomena involves atomic motion on the femtosecond time-scale. These phenomena have been studied using ultrashort optical pulses, which indirectly probe atomic positions through changes in optical properties. Because x-rays can more directly probe atomic positions, ultrashort x-ray pulses are better suited for the study of ultrafast structural dynamics. One approach towards generating ultrashort x-ray pulses is by 90{sup o} Thomson scattering between terawatt laser pulses and relativistic electrons. Using this technique, the author generated {approx} 300 fs, 30 keV (0.4 {angstrom}) x-ray pulses. These x-ray pulses are absolutely synchronized with ultrashort laser pulses, allowing femtosecond optical pump/x-ray probe experiments to be performed. Using the right-angle Thomson scattering x-ray source, the author performed time-resolved x-ray diffraction studies of laser-perturbated InSb. These experiments revealed a delayed onset of lattice expansion. This delay is due to the energy relaxation from a dense electron-hole plasma to the lattice. The dense electron-hole plasma first undergoes Auger recombination, which reduces the carrier concentration while maintaining energy content. Longitudinal-optic (LO) phonon emission then couples energy to the lattice. LO phonon decay into acoustic phonons, and acoustic phonon propagation then causes the growth of a thermally expanded layer. Source characterization is instrumental in utilizing ultrashort x-ray pulses in time-resolved x-ray spectroscopies. By measurement of the electron beam diameter at the generation point, the pulse duration of the Thomson scattered x-rays is determined. Analysis of the Thomson scattered x-ray beam properties also provides a novel means of electron bunch characterization. Although the pulse duration is inferred for the Thomson scattering x-ray source, direct measurement is required for other x-ray pulse sources. A method based on the laser-assisted photoelectric effect (LAPE) has

  16. An Imaging X-Ray Polarimetry Mission

    Science.gov (United States)

    Weisskopf, Martin C.; Bellazini, Ronaldo; Costa, Enrico; Ramsey, Brian; O'Dell, Steve; Elsner, Ronald; Pavlov, George; Matt, Giorgio; Kaspi, Victoria; Tennant, Allyn; hide

    2008-01-01

    Technical progress both in x-ray optics and in polarization-sensitive x-ray detectors, which our groups have pioneered, enables a scientifically powerful---yet inexpensive---dedicated mission for imaging x-ray polarimetry. Such a mission is sufficiently sensitive to measure x-ray (linear) polarization for a broad range of cosmic sources --particularly those involving neutron stars, stellar black holes, and supermassive black holes (active galactic nuclei). We describe the technical elements, discuss a mission concept, and synopsize the important physical and astrophysical questions such a mission would address.

  17. X-rays from the youngest stars

    Science.gov (United States)

    Feigelson, Eric D.

    1994-01-01

    The X-ray properties of classical and weak-lined T Tauri stars are briefly reviewed, emphasizing recent results from the ROSAT satellite and prospects for ASCA. The interpretation of the high level of T Tauri X-rays as enhanced solar-type magnetic activity is discussed and criticized. The census of X-ray emitters is significantly increasing estimates of galactic star formation efficiency, and X-ray emission may be important for self-regulation of star formation. ASCA images will detect star formation regions out to several kiloparsecs and will study the magnetically heated plasma around T Tauri stars. However, images will often suffer from crowding effects.

  18. X-ray emission from comets.

    Science.gov (United States)

    Cravens, T E

    2002-05-10

    The discovery of x-ray emission from comet Hyakutake was surprising given that comets are known to be cold. Observations by x-ray satellites such as the Röntgen Satellite (ROSAT) indicate that x-rays are produced by almost all comets. Theoretical and observational work has demonstrated that charge-exchange collisions of highly charged solar wind ions with cometary neutral species can explain this emission. X-ray observations of comets and other solar system objects may be used to determine the structure and dynamics of the solar wind.

  19. X-ray pulsar rush in 1998

    Energy Technology Data Exchange (ETDEWEB)

    Imanishi, K.; Tsujimoto, K.; Nishiuchi, Mamiko; Yokogawa, J.; Koyama, K. [Kyoto Univ., Faculty of Science, Kyoto (Japan)

    1999-08-01

    We present recent remarkable topics about discoveries of X-ray pulsars. 1. Pulsations from two Soft Gamma-ray Repeaters: These pulsars have enormously strong magnetic field (B {approx} 10{sup 15} G), thus these are called as 'magnetar', new type of X-ray pulsars. 2. New Crab-like pulsars: These discoveries lead to suggesting universality of Crab-like pulsars. 3. An X-ray bursting millisecond pulsar: This is strong evidence for the recycle theory of generating radio millisecond pulsars. 4. X-ray pulsar rush in the SMC: This indicates the younger star formation history in the SMC. (author)

  20. Observations of Type i X-Ray Bursts from GS 1826-238 with RXTE

    Science.gov (United States)

    Lewin, Walter

    Type I X-ray bursts are the result of thermonuclear flashes on the surface of accreting neutron stars. The spectral lines which are expected in the X-ray spectra of the bursts will allow for a direct measurement of the gravitational redshift from the surface of the neutron stars (one of the holy grails in physics). XMM-Newton has the potential of detecting such lines. We have been awarded 200 ksec observations with XMM-Newton of the X-ray burster GS 1826-238. During this time we expect to observe ten X-ray bursts and to accumulate about 40,000 high-spectral resolution burst counts with the RGS, and roughly 2 Mcounts with EPIC-PN. We are requesting simultaneous observations with RXTE to obtain essential information about the underlying continuum spectrum.

  1. Generation of attosecond soft x-ray pulses in a longitudinal space charge amplifier

    Directory of Open Access Journals (Sweden)

    M. Dohlus

    2011-09-01

    Full Text Available A longitudinal space charge amplifier (LSCA, operating in soft x-ray regime, was recently proposed. Such an amplifier consists of a few amplification cascades (focusing channel and chicane and a short radiator undulator in the end. The broadband nature of LSCA supports generation of few-cycle pulses as well as wavelength compression. In this paper we consider an application of these properties of LSCA for generation of attosecond x-ray pulses. It is shown that a compact and cheap addition to the soft x-ray free-electron laser facility FLASH would allow one to generate 60 attosecond (FWHM long x-ray pulses with the peak power at the 100 MW level and a contrast above 98%.

  2. Generation of attosecond soft X-ray pulses in a longitudinal space charge amplifier

    Energy Technology Data Exchange (ETDEWEB)

    Dohlus, M.; Schneidmiller, E.A.; Yurkov, M.V. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2011-03-15

    A longitudinal space charge amplifier (LSCA), operating in soft X-ray regime, was recently proposed. Such an amplifier consists of a few amplification cascades (focusing channel and chicane) and a short radiator undulator in the end. Broadband nature of LSCA supports generation of few-cycle pulses as well as wavelength compression. In this paper we consider an application of these properties of LSCA for generation of attosecond X-ray pulses. It is shown that a compact and cheap addition to the soft X-ray free electron laser facility FLASH would allow to generate 60 attosecond (FWHM) long X-ray pulses with the peak power at 100 MW level and a contrast above 98%. (orig.)

  3. Maxi observations of long X-ray bursts

    CERN Document Server

    Serino, Motoko; Tamagawa, Toru; Sakamoto, Takanori; Nakahira, Satoshi; Matsuoka, Masaru; Yamaoka, Kazutaka; Negoro, Hitoshi

    2016-01-01

    We report nine long X-ray bursts from neutron stars, detected with Monitor of All-sky X-ray Image (MAXI). Some of these bursts lasted for hours, and hence are qualified as superbursts, which are prolonged thermonuclear flashes on neutron stars and are relatively rare events. MAXI observes roughly 85% of the whole sky every 92 minutes in the 2-20 keV energy band, and has detected nine bursts with a long e-folding decay time, ranging from 0.27 to 5.2 hours, since its launch in 2009 August until 2015 August. The majority of the nine events were found to originate from transient X-ray sources. The persistent luminosities of the sources, when these prolonged bursts were observed, were lower than 1% of the Eddington luminosity for five of them and lower than 20% for the rest. This trend is contrastive to the 18 superbursts observed before MAXI, all but two of which originated from bright persistent sources. The distribution of the total emitted energy, i.e., the product of e-folding time and luminosity, of these bu...

  4. Mobile X-ray inspection of light weight materials

    Energy Technology Data Exchange (ETDEWEB)

    Ewert, Uwe; Redmer, Bernhard; Raedel, Christoph; Osterloh, Kurt [Federal Inst. for Materials Research and Testing (BAM), Berlin (Germany); Schnars, Ulf; Henrich, Rudolf; Schimmelmann, Olaf [Airbus, Bremen/Stade (Germany); Bavendiek, Klaus; Jahn, Mirko [YXLON International, Hamburg (Germany)

    2008-07-01

    Digital detectors such as phosphor imaging plates (IP) and digital detector arrays (DDA) allow radiographic inspection with higher efficiency and improved image quality in comparison to the classic film technique. Mobile X-ray flash tubes are used routinely for veterinarian and security applications. New high sensitive IPs and DDAs enable to apply them for inspection of light materials with low X-ray attenuation as in aluminium, plastics and composites. A versatile computed tomography (CT) system was developed for in situ inspection of large aircraft components under production conditions. A gate based planar computed tomograph was developed and tested for inspection of integrity of the stringer incorporation. Successful test trials were performed to prove the detection rate of cracks in embedded stringers. Honey comb structures of aircrafts have to be inspected for water inclusions during in-service inspections. Thermography is a powerful method for in house inspections when variations in temperature caused e.g. by sunshine can be excluded. A new X-ray diaphragm was developed for mobile back scatter measurements of large components. This method is insensitive to heat alterations in the field and thus can be applied also outdoors. (orig.)

  5. Nano structured materials studied by coherent X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Gulden, Johannes

    2013-03-15

    following chapter focuses on experiments carried out at synchrotron sources showing the potential of applying SAB-CDI to colloidal crystals. An experiment on GaAs nanowires proves the prospects of this method for other nano structured materials. To investigate dynamics, especially on the ultrafast time scale, FEL sources are needed. The next chapter therefore presents two experiments performed at the FLASH facility in Hamburg, showing that SAB-CDI can also be applied at FELs on an artificial crystal and an experiment performed on colloidal crystals to investigate the ultra fast dynamics with a pump-probe experiment. The technical advances in synchrotron radiation creation have opened the field to applications with the coherent part of the X-rays. The combination of iterative phase retrieval methods with crystallographic methods yields the unique opportunity to measure the internal structure of nano structured samples. This thesis gives an introduction into this exciting new field.

  6. European X-Ray Free Electron Laser (EXFEL): local implications

    Science.gov (United States)

    Romaniuk, Ryszard S.

    2013-10-01

    European X-Ray FEL - free electron laser is under construction in DESY Hamburg. It is scheduled to be operational at 2015/16 at a cost more than 1 billion Euro. The laser uses SASE method to generate x-ray light. It is propelled by an electron linac of 17,5GeV energy and more than 2km in length. The linac uses superconducting SRF TESLA technology working at 1,3 GHz in frequency. The prototype of EXFEL is FLASH Laser (200 m in length), where the "proof of principle" was checked, and from the technologies were transferred to the bigger machine. The project was stared in the nineties by building a TTF Laboratory -Tesla Test Facility. The EXFEL laser is a child of a much bigger teraelectronovolt collider project TESLA (now abandoned in Germany but undertaken by international community in a form the ILC). A number of experts and young researchers from Poland participate in the design, construction and research of the FLASH and EXFEL lasers.

  7. X-ray dark-field imaging for detection of foreign bodies in food

    DEFF Research Database (Denmark)

    Nielsen, Mikkel Schou; Lauridsen, Torsten; Feidenhans'l, Robert Krarup;

    2013-01-01

    Conventional X-ray transmission radiography has long been used for online detection of foreign bodies in food products relying on the absorption contrast between the foreign body and food product. In this paper, we present a novel approach for detection of organic foreign bodies such as paper...... and insects in two food products using X-ray dark-field imaging with a grating interferometer. The ability to detect the foreign bodies is quantified using a measure of the contrast-to-noise ratio. © 2012 Elsevier Ltd....

  8. Muonic X-ray spectroscopy: Effect of the presence of protons on X-ray production

    National Research Council Canada - National Science Library

    Mohamadsalehi, F; Gheisari, R; Rahimi, N

    2016-01-01

    ... . The target has a high efficiency for analyzing characteristic X-rays in ion implantation. To predict the effect of the presence of protons on X-ray production, we have proposed a new kinetic schema...

  9. SMM X-ray polychromator

    Science.gov (United States)

    Strong, Keith T.; Haisch, Bernhard M. (Compiler); Lemen, James R. (Compiler); Acton, L. W.; Bawa, H. S.; Claflin, E. S.; Freeland, S. L.; Slater, G. L.; Kemp, D. L.; Linford, G. A.

    1988-01-01

    The range of observing and analysis programs accomplished with the X-Ray Polychromator (XRP) instruments during the decline of solar cycle 21 and the rise of the solar cycle 22 is summarized. Section 2 describes XRP operations and current status. This is meant as a guide on how the instrument is used to obtain data and what its capabilities are for potential users. The science section contains a series of representative abstracts from recently published papers on major XRP science topics. It is not meant to be a complete list but illustrates the type of science that can come from the analysis of the XRP data. There then follows a series of appendixes that summarize the major data bases that are available. Appendix A is a complete bibliography of papers and presentations produced using XRP data. Appendix B lists all the spectroscopic data accumulated by the Flat Crystal Spectrometer (FCS). Appendix C is a compilation of the XRP flare catalogue for events equivalent to a GOES C-level flare or greater. It lists the start, peak and end times as well as the peak Ca XIX flux.

  10. X-ray computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kalender, Willi A [Institute of Medical Physics, University Erlangen-Nuernberg, Henkestr. 91, D-91052 Erlangen (Germany)

    2006-07-07

    X-ray computed tomography (CT), introduced into clinical practice in 1972, was the first of the modern slice-imaging modalities. To reconstruct images mathematically from measured data and to display and to archive them in digital form was a novelty then and is commonplace today. CT has shown a steady upward trend with respect to technology, performance and clinical use independent of predictions and expert assessments which forecast in the 1980s that it would be completely replaced by magnetic resonance imaging. CT not only survived but exhibited a true renaissance due to the introduction of spiral scanning which meant the transition from slice-by-slice imaging to true volume imaging. Complemented by the introduction of array detector technology in the 1990s, CT today allows imaging of whole organs or the whole body in 5 to 20 s with sub-millimetre isotropic resolution. This review of CT will proceed in chronological order focussing on technology, image quality and clinical applications. In its final part it will also briefly allude to novel uses of CT such as dual-source CT, C-arm flat-panel-detector CT and micro-CT. At present CT possibly exhibits a higher innovation rate than ever before. In consequence the topical and most recent developments will receive the greatest attention. (review)

  11. Diffraction leveraged modulation of X-ray pulses using MEMS-based X-ray optics

    Science.gov (United States)

    Lopez, Daniel; Shenoy, Gopal; Wang, Jin; Walko, Donald A.; Jung, Il-Woong; Mukhopadhyay, Deepkishore

    2016-08-09

    A method and apparatus are provided for implementing Bragg-diffraction leveraged modulation of X-ray pulses using MicroElectroMechanical systems (MEMS) based diffractive optics. An oscillating crystalline MEMS device generates a controllable time-window for diffraction of the incident X-ray radiation. The Bragg-diffraction leveraged modulation of X-ray pulses includes isolating a particular pulse, spatially separating individual pulses, and spreading a single pulse from an X-ray pulse-train.

  12. X-ray lasers: Multicolour emission

    Science.gov (United States)

    Feng, Chao; Deng, Haixiao

    2016-11-01

    The X-ray free-electron laser at the SLAC National Accelerator Laboratory in the US can now generate multicolour X-ray pulses with unprecedented brightness using the fresh-slice technique. The development opens the way to new forms of spectroscopy.

  13. X-Ray Detection Visits the Classroom

    Science.gov (United States)

    Peralta, Luis; Farinha, Ana; Pinto, Ana

    2008-01-01

    Film has been used to detect x-rays since the early days of their discovery by Rontgen. Although nowadays superseded by other techniques, film still provides a cheap means of x-ray detection, making it attractive in high-school or undergraduate university courses. If some sort of quantitative result is required, the film's optical absorbance or…

  14. Accelerator-driven X-ray Sources

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Dinh Cong [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-11-09

    After an introduction which mentions x-ray tubes and storage rings and gives a brief review of special relativity, the subject is treated under the following topics and subtopics: synchrotron radiation (bending magnet radiation, wiggler radiation, undulator radiation, brightness and brilliance definition, synchrotron radiation facilities), x-ray free-electron lasers (linac-driven X-ray FEL, FEL interactions, self-amplified spontaneous emission (SASE), SASE self-seeding, fourth-generation light source facilities), and other X-ray sources (energy recovery linacs, Inverse Compton scattering, laser wakefield accelerator driven X-ray sources. In summary, accelerator-based light sources cover the entire electromagnetic spectrum. Synchrotron radiation (bending magnet, wiggler and undulator radiation) has unique properties that can be tailored to the users’ needs: bending magnet and wiggler radiation is broadband, undulator radiation has narrow spectral lines. X-ray FELs are the brightest coherent X-ray sources with high photon flux, femtosecond pulses, full transverse coherence, partial temporal coherence (SASE), and narrow spectral lines with seeding techniques. New developments in electron accelerators and radiation production can potentially lead to more compact sources of coherent X-rays.

  15. X-raying clumped stellar winds

    CERN Document Server

    Oskinova, L M; Feldmeier, A

    2008-01-01

    X-ray spectroscopy is a sensitive probe of stellar winds. X-rays originate from optically thin shock-heated plasma deep inside the wind and propagate outwards throughout absorbing cool material. Recent analyses of the line ratios from He-like ions in the X-ray spectra of O-stars highlighted problems with this general paradigm: the measured line ratios of highest ions are consistent with the location of the hottest X-ray emitting plasma very close to the base of the wind, perhaps indicating the presence of a corona, while measurements from lower ions conform with the wind-embedded shock model. Generally, to correctly model the emerging X-ray spectra, a detailed knowledge of the cool wind opacities based on stellar atmosphere models is prerequisite. A nearly grey stellar wind opacity for the X-rays is deduced from the analyses of high-resolution X-ray spectra. This indicates that the stellar winds are strongly clumped. Furthermore, the nearly symmetric shape of X-ray emission line profiles can be explained if t...

  16. X-rays, clumping and wind structures

    Science.gov (United States)

    Oskinova, Lidia; Hamann, Wolf-Rainer; Ignace, Richard; Feldmeier, Achim

    2011-01-01

    X-ray emission is ubiquitous among massive stars. In the last decade, X-ray observations revolutionized our perception of stellar winds but opened a Pandora's box of urgent problems. X-rays penetrating stellar winds suffer mainly continuum absorption, which greatly simplifies the radiative transfer treatment. The small and large scale structures in stellar winds must be accounted for to understand the X-ray emission from massive stars. The analysis of X-ray spectral lines can help to infer the parameters of wind clumping, which is prerequisite for obtaining empirically correct stellar mass-loss rates. The imprint of large scale structures, such as CIRs and equatorial disks, on the X-ray emission is predicted, and new observations are testing theoretical expectations. The X-ray emission from magnetic stars proves to be more diverse than anticipated from the direct application of the magnetically-confined wind model. Many outstanding questions about X-rays from massive stars will be answered when the models and the observations advance.

  17. Cryogenic imaging x-ray spectrometer

    NARCIS (Netherlands)

    Wiegerink, Remco J.; van Baar, J.J.J.; de Boer, J.H.; Ridder, M.L.; Bruijn, M.P.; Germeau, A.; Hoevers, H.F.C.

    2005-01-01

    A micro-calorimeter array consisting of superconducting transition-edge sensors is under development for the X-ray imaging spectrometer on board of ESA's XEUS (X-ray Evolving Universe Spectroscopy) mission. An array of 32 /spl times/ 32 pixels with a pixel size of 250 micron square is envisaged. So

  18. Low Energy X-Ray Diagnostics - 1981.

    Science.gov (United States)

    1981-01-01

    Filtering, and Scattering of Soft X-Rays by Mirrors Victor Rehn Michelson Laboratory, Physics Division Naval Weapons Center, China Lake, California...met with in K.Tregidgo, 18, 2003 (1979). the manufacture of X-ray optical components. In 32. W.P.Linnik, C. R. Acad. Sci. URSS ., 5, 210 (1933). general

  19. New Insights into X-ray Binaries

    CERN Document Server

    Casares, Jorge

    2009-01-01

    X-ray binaries are excellent laboratories to study collapsed objects. On the one hand, transient X-ray binaries contain the best examples of stellar-mass black holes while persistent X-ray binaries mostly harbour accreting neutron stars. The determination of stellar masses in persistent X-ray binaries is usually hampered by the overwhelming luminosity of the X-ray heated accretion disc. However, the discovery of high-excitation emission lines from the irradiated companion star has opened new routes in the study of compact objects. This paper presents novel techniques which exploits these irradiated lines and summarises the dynamical masses obtained for the two populations of collapsed stars: neutron stars and black holes.

  20. Perspectives of medical X-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Freudenberger, J. E-mail: joerg.freudenberger@med.siemens.de; Hell, E.; Knuepfer, W

    2001-06-21

    While X-ray image intensifiers (XII), storage phosphor screens and film-screen systems are still the work horses of medical imaging, large flat panel solid state detectors using either scintillators and amorphous silicon photo diode arrays (FD-Si), or direct X-ray conversion in amorphous selenium are reaching maturity. The main advantage with respect to image quality and low patient dose of the XII and FD-Si systems is caused by the rise of the Detector Quantum Efficiency originating from the application of thick needle-structured phosphor X-ray absorbers. With the detectors getting closer to an optimal state, further progress in medical X-ray imaging requires an improvement of the usable source characteristics. The development of clinical monochromatic X-ray sources of high power would not only allow an improved contrast-to-dose ratio by allowing smaller average photon energies in applications but would also lead to new imaging techniques.