  1. An algorithm for applying flagged Sysmex XE-2100 absolute neutrophil counts in clinical practice

    DEFF Research Database (Denmark)

    Friis-Hansen, Lennart; Saelsen, Lone; Abildstrøm, Steen Z

    2008-01-01

    BACKGROUND: Even though most differential leukocyte counts are performed by automated hematology platforms, turn-around time is often prolonged as flagging of test results trigger additional confirmatory manual procedures. However, frequently only the absolute neutrophil count (ANC) is needed. We...... therefore examined if an algorithm could be developed to identify samples in which the automated ANC is valid despite flagged test results. METHODS: During a 3-wk period, a training set consisting of 1448 consecutive flagged test-results from the Sysmex XE-2100 system and associated manual differential...... counts was collected. The training set was used to determine which alarms were associated with valid ANCs. The algorithm was then tested on a new set of 1371 test results collected during a later 3-wk period. RESULTS: Analysis of the training set data revealed that the ANC from test results flagged...

  2. Performance evaluation of the Sysmex® XE-2100D automated hematology analyzer

    Directory of Open Access Journals (Sweden)

    Tavany Elisa Santos Maciel

    2014-02-01

    Full Text Available Introduction: The Sysmex® XE-2100D is a multiparameter hematology analyzer designed for hematology testing in samples with ethylenediamine tetraacetic acid (EDTA. Objectives: Considering the importance of this hematology analyzer for clinical and laboratory practice, the objective of this study was to evaluate its analytical performance, comparing the obtained results with quality specifications described in literature. Material and method: In the evaluation of analytical performance, according to recommendations of the document H26-A2 of the Clinical and Laboratory Standards Institute (CLSI, intra-run imprecision, inter-run imprecision, linearity, carryover, autosampler evaluation, clinical sensitivity of the atypical lymphocytes flag (n = 400 samples were included, as well as the comparison between automated and manual leukocyte differential count (n = 400 samples, based on an adaptation of the document H20-A2 of CLSI. Results: Repeatability, reproducibility, linearity and carryover were satisfactory according to the manufacturer's specifications. The clinical sensitivity of the atypical lymphocytes flag showed efficiency, sensitivity and specificity of 92.5%, 65.2% and 94.1% respectively. The correlation coefficients between the automated and manual differential counts of neutrophils, lymphocytes, monocytes, eosinophils and basophils were 0.991, 0.99, 0.872, 0.974 and 0.557, respectively. Conclusions: The results were in accordance with quality specifications described in literature, indicating reliability in Sysmex® XE-2100D. This fact ensures certainty to both laboratory professionals and medical staff. We conclude that the Sysmex® XE-2100D showed excellent analytical performance, and is useful to provide reliable hematology data.

  3. Hypo- and hypernatremia results in inaccurate erythrocyte mean corpuscular volume measurement in vitro, when using Sysmex XE 2100

    DEFF Research Database (Denmark)

    Phillipsen, Jens Peter; Madsen, Kirsten Vikkelsø

    2015-01-01

    INTRODUCTION: Automated hematology analyzers dilute patient erythrocytes with an isoosmotic diluent before quantitating the erythrocyte mean cell volume (MCV). However, if patient plasma osmolality differs from the diluent, water will cross the erythrocytes membrane and establish a new equilibrium...... across the membrane. Since the new equilibrium is reached before the measurement of the MCV, the measured MCV may not reflect the true MCV in vivo. AIM: Calculation of the theoretical change in MCV at changed P-Sodium/P-Osmolality and to investigate if the automated blood cell counter Sysmex XE 2100...

  4. Comparison of platelet counts by sysmex XE 2100 and LH-750 with the international flow reference method in thrombocytopenic patients

    Directory of Open Access Journals (Sweden)

    Tina Dadu

    2013-01-01

    Full Text Available Background: There are several methods for counting platelets, of which the international flow reference method (IRM is considered to be the gold standard. We compared the platelet count given by this method to the count given by automated analyzers using other methods, such as optical fluorescence and impedance. Aims: The aim of this study is to compare the platelet counts obtained by Sysmex XE 2100 by Impedance (Sysmex-I, optical florescence (Sysmex-O and reported (Sysmex-R based on the switching algorithm and LH-750 by Impedance (LH-750 with the IRM in thrombocytopenic blood samples. To calculate the sensitivity, specificity, positive predictive value (PPV and negative predictive value (NPV of various technologies at the clinically relevant transfusion thresholds of 10 × 10 9 /l and 20 × 10 9 /l. Materials and Methods: A total of 118 blood samples with platelet count of <50 × 10 9 /l were selected for the study. Platelet counts of all samples were analyzed by all methods using the Sysmex analyzer, LH-750 and IRM in parallel within 6 h of collection. Statistical Analysis Used: Pearson correlation, bland Altman analysis, sensitivity and specificity, PPV and NPV. Results and Conclusions: Sysmex-R had the least Bias and 95% limits of agreement (95%LA range and thus correlated best with IRM values. LH-750 had a higher Bias compared to Sysmex-O and Sysmex-R, but a strikingly similar 95% LA ensures similar results in all three methods. In fact, in the oncology subset, it had the narrowest 95% LA, which made it the best performer in this subgroup. Of the three Sysmex results, Sysmex-I had the highest bias, widest 95% LA and highest potential risk of over transfusion. Hence, Sysmex-R and LH-750 were found to be reliable tools for estimation of platelet count in thrombocytopenic patients.

  5. Design of Malaria Diagnostic Criteria for the Sysmex XE-2100 Hematology Analyzer

    Science.gov (United States)

    Campuzano-Zuluaga, Germán; Álvarez-Sánchez, Gonzalo; Escobar-Gallo, Gloria Elcy; Valencia-Zuluaga, Luz Marina; Ríos-Orrego, Alexandra Marcela; Pabón-Vidal, Adriana; Miranda-Arboleda, Andrés Felipe; Blair-Trujillo, Silvia; Campuzano-Maya, Germán

    2010-01-01

    Thick film, the standard diagnostic procedure for malaria, is not always ordered promptly. A failsafe diagnostic strategy using an XE-2100 analyzer is proposed, and for this strategy, malaria diagnostic models for the XE-2100 were developed and tested for accuracy. Two hundred eighty-one samples were distributed into Plasmodium vivax, P. falciparum, and acute febrile syndrome groups for model construction. Model validation was performed using 60% of malaria cases and a composite control group of samples from AFS and healthy participants from endemic and non-endemic regions. For P. vivax, two observer-dependent models (accuracy = 95.3–96.9%), one non–observer-dependent model using built-in variables (accuracy = 94.7%), and one non–observer-dependent model using new and built-in variables (accuracy = 96.8%) were developed. For P. falciparum, two non–observer-dependent models (accuracies = 85% and 89%) were developed. These models could be used by health personnel or be integrated as a malaria alarm for the XE-2100 to prompt early malaria microscopic diagnosis. PMID:20207864

  6. Comparison of five automated hematology analyzers in a university hospital setting: Abbott Cell-Dyn Sapphire, Beckman Coulter DxH 800, Siemens Advia 2120i, Sysmex XE-5000, and Sysmex XN-2000.

    Science.gov (United States)

    Bruegel, Mathias; Nagel, Dorothea; Funk, Manuela; Fuhrmann, Petra; Zander, Johannes; Teupser, Daniel

    2015-06-01

    Various types of automated hematology analyzers are used in clinical laboratories. Here, we performed a side-by-side comparison of five current top of the range routine hematology analyzers in the setting of a university hospital central laboratory. Complete blood counts (CBC), differentials, reticulocyte and nucleated red blood cell (NRBC) counts of 349 patient samples, randomly taken out of routine diagnostics, were analyzed with Cell-Dyn Sapphire (Abbott), DxH 800 (Beckman Coulter), Advia 2120i (Siemens), XE-5000 and XN-2000 (Sysmex). Inter-instrument comparison of CBCs including reticulocyte and NRBC counts and investigation of flagging quality in relation to microscopy were performed with the complete set of samples. Inter-instrument comparison of five-part differential was performed using samples without atypical cells in blood smear (n=292). Automated five-part differentials and NRBCs were additionally compared with microscopy. The five analyzers showed a good concordance for basic blood count parameters. Correlations between instruments were less well for reticulocyte counts, NRBCs, and differentials. The poorest concordance for NRBCs with microscopy was observed for Advia 2120i (Kendall's τb=0.37). The highest flagging sensitivity for blasts was observed for XN-2000 (97% compared to 65%-76% for other analyzers), whereas overall specificity was comparable between different instruments. To the best of our knowledge, this is the most comprehensive side-by-side comparison of five current top of the range routine hematology analyzers. Variable analyzer quality and parameter specific limitations must be considered in defining laboratory algorithms in clinical practice.

  7. Comparison study of the rates of manual peripheral blood smear review from 3 automated hematology analyzers, Unicel DxH 800, ADVIA 2120i, and XE 2100, using international consensus group guidelines.

    Science.gov (United States)

    Kim, Sue Jung; Kim, Yoonjung; Shin, Saeam; Song, Jaewoo; Choi, Jong Rak

    2012-11-01

    In the clinical laboratory, it is important both to reduce the number of peripheral blood slide reviews to save time and money and to avoid reporting false results. To determine differences in the slide review rates of 3 widely used automated hematologic analyzers, the Unicel DxH 800 (Beckman Coulter Inc, Fullerton, California), ADVIA 2120i (Siemens Diagnostics, Tarrytown, New York), and XE 2100 (Sysmex, Kobe, Japan), using International Consensus Group for Hematology Review guidelines. A total of 1485 samples were tested, and 300 were manually reviewed. Slide review rates, sensitivity, specificity, and false-positive and false-negative rates were estimated using consensus group rules and compared using χ(2) tests, Fisher exact tests, or generalized estimating equations. Unicel DxH 800, ADVIA 2120i, and XE 2100 showed 22.8%, 20.2%, and 28.6% slide review rates; 14.3%, 14.3%, and 9.7% false-negative rates; and 13.7, 11.3%, and 17.3% false-positive rates, respectively. All analyzers showed significantly higher false-negative rates than that of the consensus group (2.9%). False-negative rates were higher than the recommended levels. Among 3 automated hematologic analyzers, XE 2100 showed the highest rate of slide review. Because the present study clearly shows that the slide review rates have distinct characteristics among the studied analyzers, each individual laboratory should consider selecting the most appropriate analyzer according to clinical characteristics. Analyzers with high sensitivity may be advantageous in outpatient settings for screening patients, whereas analyzers with high specificity may be beneficial in inpatient settings for efficient patient care.

  8. Reference intervals for mean platelet volume and immature platelet fraction determined on a sysmex XE5000 hematology analyzer

    DEFF Research Database (Denmark)

    Jørgensen, Mikala Klok; Bathum, L.

    2016-01-01

    Background New parameters describing the platelet population of the blood are mean platelet volume (MPV), which is a crude estimate of thrombocyte reactivity, and immature platelet fraction (IPF), which reflects megakaryopoietic activity. This study aimed to define reference intervals for MPV...... and IPF and to investigate whether separate reference intervals according to smoking status, age or sex are necessary.Methods Blood samples were obtained from subjects participating in The Danish General Suburban Population Study. MPV and IPF measurements were performed by the use of the Sysmex XE-5000...

  9. Performance Evaluation of the Sysmex CS-5100 Automated Coagulation Analyzer.

    Science.gov (United States)

    Chen, Liming; Chen, Yu

    2015-01-01

    Coagulation testing is widely applied clinically, and laboratories increasingly demand automated coagulation analyzers with short turn-around times and high-throughput. The purpose of this study was to evaluate the performance of the Sysmex CS-5100 automated coagulation analyzer for routine use in a clinical laboratory. The prothrombin time (PT), international normalized ratio (INR), activated partial thromboplastin time (APTT), fibrinogen (Fbg), and D-dimer were compared between the Sysmex CS-5100 and Sysmex CA-7000 analyzers, and the imprecision, comparison, throughput, STAT function, and performance for abnormal samples were measured in each. The within-run and between-run coefficients of variation (CV) for the PT, APTT, INR, and D-dimer analyses showed excellent results both in the normal and pathologic ranges. The correlation coefficients between the Sysmex CS-5100 and Sysmex CA-7000 were highly correlated. The throughput of the Sysmex CS-5100 was faster than that of the Sysmex CA-7000. There was no interference at all by total bilirubin concentrations and triglyceride concentrations in the Sysmex CS-5100 analyzer. We demonstrated that the Sysmex CS-5100 performs with satisfactory imprecision and is well suited for coagulation analysis in laboratories processing large sample numbers and icteric and lipemic samples.

  10. Reliability of point-of-care hematocrit, blood gas, electrolyte, lactate and glucose measurement during cardiopulmonary bypass.

    Science.gov (United States)

    Steinfelder-Visscher, J; Weerwind, P W; Teerenstra, S; Brouwer, M H J

    2006-01-01

    Recently, the GEM Premier blood gas analyser was upgraded to the GEM Premier 3000. In addition to pH, pCO2, pO2, Na+, K+, Ca2+, and hematocrit measurement, glucose and lactate can be measured on the GEM Premier 3000. In this prospective clinical study, the analytical performance of the GEM Premier 3000 was compared with the Ciba Corning 865 analyser for blood gas/electrolytes/metabolites, and for hematocrit with the Sysmex XE 2100 instrument. During a 6-month period, 127 blood samples were analysed on both the GEM Premier 3000 analyser and our laboratory analysers (Ciba Corning 865/Sysmex 2100 instrument), and compared using the agreement analysis for quantitative data. With the exception of K+, the other parameters (pCO2, pO2, Na+, Ca2+, hematocrit, glucose, and lactate) can be described in terms of the mean and standard deviation of the differences. For K+ measurement, a clear linear trend (r=0.79, panalyser seems to be suitable for point-of-care testing of electrolytes, metabolites, and blood gases during cardiopulmonary bypass. However, its downward bias in hematocrit values below 30% suggests that using the GEM Premier 3000 as a transfusion trigger leads to overtreatment with packed red cells.

  11. Performance evaluation of XN-1000 Sysmex blood cell count of low value of white blood cell%Sysmex XN-1000血细胞分析仪计数低值白细胞性能的评估

    Institute of Scientific and Technical Information of China (English)

    蒋清清; 马萍; 丁爽

    2016-01-01

    目的:探讨 Sysmex XN‐1000(后简称 XN‐1000)全自动血细胞分析仪检测白细胞计数(WBC)及分类的准确性。方法收集该院2015年1~4月门诊及住院患者及健康体检者共206例,根据人工镜检检测 WBC 结果分为高值组(WBC >10.0×109/L),健康组(4.0×109/L < WBC ≤10.0×109/L)和低值组(1.5×109/L < WBC ≤4.0×109/L)。再分别用 XN‐1000与Sysmex XE‐5000(后简称 XE‐5000)进行 WBC 并分类。采用统计学软件对3种方法的结果进行对比分析,并进行相关性分析。结果3种方法检测 WBC 结果比较,高值组和健康组差异无统计学意义(P>0.05),结果具有正相关性。低值组中,XN‐1000检测结果准确性与 XE‐5000差异无统计学意义(P>0.05),但是白细胞分类结果显著高于 XE‐5000(P<0.05);对于异常细胞,XN‐1000和 XE‐5000不能进行有效分类,仍需人工镜检进行分类。结论 XN‐1000全自动血细胞分析仪在 WBC 与 XE‐5000及人工镜检比较无差异统计学意义,在测定白细胞分类上 XN‐1000较 XE‐5000更准确(XN‐1000合格率91%,XE‐5000合格率63%),但仍不能完全替代人工镜检。对于异常细胞,XN‐1000不能有效分类,需与人工镜检结合。%Objective To investigate the accuracy of XN‐1000 automatic blood cell analyzer in detecting of white blood cell (WBC) count and classification .Methods A total of 206 cases including outpatients ,inpatients and health people were collected in the hospital from January to April 2015 .According to manual microscopy detection of white blood cell count results ,the cases were divided into three groups :high value of white blood cell(WBC was more than 10 .0 × 109 /L) group ,normal value of white blood cells group(WBC was more than 4 .0 × 109 /L but less than 10 .0 × 109 /L) and low value of white blood cell(WBC was more than 1 .5 × 109 /L

  12. Evaluation of the i-STAT point-of-care capillary whole blood hematocrit and hemoglobin: Comparison to the Siemens RAPIDLab 1200, Sysmex XE5000, and manual spun hematocrit.

    Science.gov (United States)

    Rudolf, Joseph; Douglass, Joseph; Baron, Jason; Lewandrowski, Kent

    2015-06-15

    Conductivity based point-of-care hematocrit with calculated hemoglobin devices serves an important role in clinical scenarios where time sensitive transfusion decisions are necessary. However, questions about the appropriateness of conductivity based assays in certain patient populations (patients on cardiopulmonary bypass and those receiving high volumes of intravenous fluids or autologous blood transfusions) have been raised. The clinical suitability of POC devices for these applications necessitates that they be accurate and that the results are interchangeable with central laboratory methods. We performed hematocrit and hemoglobin analysis on 225 clinical samples using the i-STAT instrument, a standard reference method for hematocrit (manual spun) and other common methods on both cardiopulmonary bypass and non-cardiopulmonary bypass patients. The i-STAT hematocrit and hemoglobin showed close agreement to comparison methods with minimal bias. Median test results were not clinically or statistically different between those measured on the i-STAT and those measured using the manual spun hematocrit reference method (p=0.4085, Wilcoxon signed rank test) or the Sysmex photometric hemoglobin method (p=0.2728, Wilcoxon signed rank test). The results on the i-STAT were statistically different from those obtained on the Sysmex for hematocrit (phemoglobin (phematocrit and hemoglobin performs well when compared to the hematocrit reference method and other common methods for both hematocrit and hemoglobin. Some differences between non-reference methods may be observed, but these were not considered clinically significant. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. New spectroscopic results in Xe II, Xe III, and Xe IV

    OpenAIRE

    Reyna Almandos, Jorge Guillermo; Gallardo, Mario; Garavaglia, Mario J.

    1982-01-01

    New results obtained in spontaneous xenon spectrum employing a conventional pulsed gaseous laser tube as light source, are presented in this work. A total of 626 spectral lines has been ionically assigned as follows: 50 to Xe II spectrum, 103 to Xe III spectrum, arid 222 to Xe IV spectrum. 30 Lines previously assigned to Xe II were reassigned as belonging to Xe III, 94 lines were assigned with some doubts to Xe II-III spectrum and 84 lines to Xe Ill-IV spectrum. Also there were clas...

  14. Double beta decay searches of 134Xe, 126Xe and 124Xe with large scale Xe detectors

    International Nuclear Information System (INIS)

    Barros, N; Thurn, J; Zuber, K

    2014-01-01

    The sensitivity for double beta decay studies of 134 Xe and 124 Xe is investigated assuming a potential large scale Xe experiment developed for dark matter searches depleted in 136 Xe. The opportunity for an observation of the 2νββ - decay of 134 Xe is explored for various scenarios. A positive observation should be possible for all calculated nuclear matrix elements. The detection of 2ν ECEC of 124 Xe can be probed in all scenarios covering the theoretical predicted half-life uncertainties and a potential search for 126 Xe is discussed. The sensitivity to β + EC decay of 124 Xe is discussed and a positive observation might be possible, while β + β + decay still remains unobservable. The performed studies take into account solar pp–neutrino interactions, 85 Kr beta decay and remaining 136 Xe double beta decay as background components in the depleted detector. (paper)

  15. Feasibility study of white blood cell count in cerebrospinal fluid and hydrothorax and ascites with Sysmex ;XN-1000 hematology analyzer%SYSMEX XN-1000血球仪在脑脊液和胸腹水白细胞计数中的可行性探讨

    Institute of Scientific and Technical Information of China (English)

    叶小英; 范春丽; 陆敏; 卞洁

    2016-01-01

    Objective To analyze the feasibility of using body fluid module of Sysmex XN-1000 hematology analyzer for white blood cell count in the cerebrospinal fluid (CSF), hydrothorax and ascites. Methods Microscope method and Sysmex XN-1000 hematology analyzer were used to analyze 183 samples of CSF, hydrothorax and ascites at the same time. The measured results were divided into three groups:group A:0~1 000×106/L, B:1 001~5 000×106/L, C:>5 000×106/L. The results were statistically analyzed. Results Compared with the results of microscope, the results of Sysmex XN-1000 hematology analyzer showed no statistically significant difference (P>0.05). The correlation coeffi-cients of group A, B, C were 0.993, 0.984, 0.996, with the regression equation of y=1.007x-1.072, y=1.003+19.776x, y=1.241-1 419.365x, respectively. Conclusion The body fluid module of Sysmex XN-1000 hematology analyzer can be used for white blood cell count in clinical CSF and hydrothorax and ascites, with simple operation and reliable results. When the instrument is alarmed on the sample test, we should use manual microscopy review to improve the veracity and reliability of the results.%目的:探讨SYSMEX XN-1000血液分析仪(简称SYSMEX XN-1000)的体液模式在脑脊液和胸腹水白细胞计数中应用的可行性。方法分别采用手工显微镜镜检法和SYSMEX XN-1000对183例脑脊液和胸腹水标本进行白细胞计数,将所测结果按A:(0~1000)×106/L,B:(1001~5000)×106/L,C:>5000×106/L分为三组,分别进行统计学分析。结果与手工显微镜镜检法相比,SYSMEX XN-1000所测结果差异无统计学意义(P>0.05)。A、B、C三组的相关系数分别为0.993、0.984、0.996,A组回归方程为y=1.007x-1.072,B组回归方程为y=1.003x+19.776,C组回归方程为y=1.241x-1419.365。结论 SYSMEX XN-1000血液分析仪可用于临床脑脊液和胸腹水中白细胞计数,其操作简单易行,结果稳定可靠,但如果仪器进行样品检测时报警,应当手工镜检复核,以提高结果的准确性和可靠性。

  16. Ionization energies of Xe2+ and Xe3+

    International Nuclear Information System (INIS)

    Dutil, R.; Marmet, P.

    1980-01-01

    New electron impact measurements show that the previously accepted energies of ionization of Xe 2+ and Xe 3+ from xenon are erroneous. These energies are determined 33.11 +- 0.04 eV for Xe 2+ and 64.35 +- 0.10 eV for Xe 3+ . New structures are seen by electron impact just above the Xe 2+ threshold. New information is also given on the ionization energies of Xe 4+ and Xe 5+ . (orig.)

  17. Primordial Terrestrial Xe from the Viewpoint of CFF-Xe

    Science.gov (United States)

    Meshik, A. P.; Shukolyukov, Yu. A.; Jessberger, E. K.

    1995-09-01

    We have already reported [7, 23] on the non-linear isotope mass-fractionation of fission Xe by migration of the precursors I, Te, Sn, and Sb and simultaneous fission of heavy nuclei. Xe with anomalous isotopic pattern was found in a number of meteorites and terrestrial materials and was named CFF-Xe (Chemically Fractionated Fission Xe). It is characterized by an up eightfold ^132Xe and ^131Xe excesses coupled with smaller ^134Xe and ^129Xe excesses. The present work is aimed to estimate the role of CFF-Xe in the terrestrial lithosphere and specifically deals with the problem of the isotopic composition of primordial terrestrial Xe. Due to variations of the migration conditions the isotopic structure of CFF-Xe is not well established and is even not reproducible in the same rock [2]. Nevertheless, we have tried to estimate the composition of CFF-Xe by investigating all available isotopic data of Xe of presumable mantle origin. This is Xe in MORB [29, 1, 12] and ocean island glasses [1, 28], in diamonds [17], in volcanic rocks [29, 8, 9, 21], in volcanic glasses from pillow basalts [16, 6], continental igneous rocks [1, 24, 10, 22], carbonatites and granitoids [1] as well as Xe in natural gases [3, 24, 11, 4, 15]. All data are plotted Fig. 1 where we also suggest end members of the observed scattering. Optimized slopes of CFF-lines are shown as well as the position of the initial points which we regard as primordial terrestrial Xe (Xe0). The isotopic composition of CFF-Xe and Xe0 are given in Tab. 1. The abundances of ^124Xe and ^126Xe in mantle derived samples are very uncertain, but since ^128Xe/^130Xe in Xea and Xe0 is very similar we propose the same ^124Xe/^130Xe and ^126Xe/^130Xe ratios for both Xea and Xe0. If so, AVCC-Xe is simply Xe0 with an admixture of L-Xe, and atmospheric xenon Xea consists of Xe0, CFF-Xe and a small amount of fission Xe (92.5%Xe0 + 5.3%CFF-Xe + 2.2%XeF). Thus, a number of old problems in xenology are removed. The hypothetic components U-Xe

  18. 124Xe(n,γ)125Xe and 124Xe(n,2n)123Xe measurements for National Ignition Facility

    Science.gov (United States)

    Bhike, Megha; Ludin, Nurin; Tornow, Werner

    2015-05-01

    The cross section for the 124Xe(n,γ)125Xe reaction has been measured for the first time for neutron energies above 100 keV. In addition, the 124Xe(n,2n)123Xe reaction has been studied between threshold and 14.8 MeV. The results of these measurements provide sensitive diagnostic tools for investigating properties of the inertial confinement fusion plasma in Deuterium-Tritium (DT) capsules at the National Ignition Facility (NIF) located at Lawrence Livermore National Laboratory.

  19. 124Xe(n,γ125Xe and 124Xe(n,2n123Xe measurements for National Ignition Facility

    Directory of Open Access Journals (Sweden)

    Bhike Megha

    2015-01-01

    Full Text Available The cross section for the 124Xe(n,γ125Xe reaction has been measured for the first time for neutron energies above 100 keV. In addition, the 124Xe(n,2n123Xe reaction has been studied between threshold and 14.8 MeV. The results of these measurements provide sensitive diagnostic tools for investigating properties of the inertial confinement fusion plasma in Deuterium-Tritium (DT capsules at the National Ignition Facility (NIF located at Lawrence Livermore National Laboratory.

  20. Training warning flags

    International Nuclear Information System (INIS)

    Miller, Richard C.

    2003-01-01

    Problems in accredited training programmes at US nuclear stations have resulted in several programmes having their accreditation status designated as probationary. A limited probationary period allows time for problem resolution before the programmes are again reviewed by the National Nuclear Accrediting Board. A careful study of these problems has resulted in the identification of several 'Training Warning Flags' that singularly, or in concert, may indicate or predict degraded training programme effectiveness. These training warning flags have been used by several US nuclear stations as a framework for self-assessments, as a reference in making changes to training programmes, and as a tool in considering student and management feedback on training activities. Further analysis and consideration of the training warning flags has developed precursors for each of the training warning flags. Although more subjective than the training warning flags, the precursors may represent early indicators of factors that may lead to or contribute to degraded training programme effectiveness. Used as evaluative tools, the training warning flags and the precursors may help identify areas for improvements in training programmes and help prioritize training programme improvement efforts. (author)

  1. The Accuracy of the Sysmex UF-1000i in Urine Bacterial Detection Compared With the Standard Urine Analysis and Culture.

    Science.gov (United States)

    Erdman, Patrick; Anderson, Brian; Zacko, J Christopher; Taylor, Kirk; Donaldson, Keri

    2017-11-01

    - Urinary tract infections are characterized by the presence of microbial pathogens within the urinary tract. They represent one of the most common infections in hospitalized and clinic patients. - To model the parameters of the Sysmex UF-1000i to the gold standard, urine culture, and to compare the detection of dipstick leukocyte esterase and nitrates to urine cultures and UF-1000i results. - Data were compared from urine samples collected in sterile containers for bacterial culture and microscopic analysis. One sample was used to inoculate a 5% sheep blood agar and MacConkey agar plate using a 0.001-mL calibrated loop. The second sample was analyzed by urinalysis-associated microscopy. The media plates were investigated for growth after 18 to 24 hours of aerobic incubation at 37°C. The second sample was analyzed for bacteria and leukocytes with the Sysmex UF-1000i according to the manufacturer's guidelines. Three definitions for culture results, sensitivity, and specificity at different cutoff values were calculated for the UF-1000i. - The negative predictive value for any positive culture in the adult population included in the study was 95.5%, and the negative predictive value for positive cultures containing growth of 100 000 or more colony-forming units was 99.3% using the Sysmex UF-1000i. - Sysmex UF-1000i showed 98% sensitivity and 93.7% specificity with a 95.5% negative predictive value. Thus, a negative screen with the UF-1000i using defined thresholds for white blood cell counts and bacteria was likely to be a true negative, decreasing the need for presumptive antibiotics.

  2. Flow measurements in biological systems using Xe-127 and Xe-133

    International Nuclear Information System (INIS)

    Tripathi, R.R.

    1981-01-01

    Xe-133 and Xe-127 are widely used for quantitative evaluation of ventilation in human subjects. Owing to differences in scattering in the biological system as well as differences in the detector response to photons of selected energies, clinical Xe-133 images are much more distorted than the corresponding Xe-127 images. This thesis concerns itself with the evaluation of Xe-133 and Xe-127 as potential tracers for pulmonary function studies. Through the simulation of clinical images it is shown that such smaller abnormalities are able to be detected with Xe-127 than with Xe-133. It is also found that even for poorly ventilated regions, the measured lesion size in the simulated image is comparable to the known lesion size when studied with Xe-127. With Xe-133, however, the measured size of the lesion is smaller than its known size. By fitting the washout portion of the clinical data to a linear sum of two exponentials, a weighted average clearance constant for the tracer - which relates to the reciprocal of the mean flow through the system - can be calculated and used as an index for comparison of the two Xenon isotopes. When an appropriate model is used for data interpretation, more accurate clinical information can be derived from the Xe-127 data. Unlike Xe-133, ventilation study with Xe-127 can be performed immediately after the perfusion study with Tc-99m. Lower radiation dose and longer shelf-life of Xe-127 are added advantages over Xe-133. Various compartmental and non-compartmental models are examined and appropriate technique(s) for clinical data interpretation is(are) recommended

  3. Hemopoietic stem and precursor cell analysis in umbilical cord blood using the Sysmex SE-9000 IMI channel

    NARCIS (Netherlands)

    Kraai, R; Reymer, AGF; Brouwer-Mandema, GG; van Beckhoven, JM; Hoogeboom, M; le Cessie, S; Kluin-Nelemans, J.C.

    2001-01-01

    Circulating hematopoietic progenitor cells (HPCs) are routinely measured by flow cytometry using CD34 expression. As an alternative, the "immature information" (IMI) channel measurement of the automated hematology analyzer Sysmex SE machines was developed. We tested the IMI channel HPC method with

  4. Anisotropic flow in Xe-Xe collisions at 5.44 TeV

    CERN Document Server

    Acharya, Shreyasi; The ALICE collaboration; Adamova, Dagmar; Adolfsson, Jonatan; Aggarwal, Madan Mohan; Aglieri Rinella, Gianluca; Agnello, Michelangelo; Agrawal, Neelima; Ahammed, Zubayer; Ahn, Sang Un; Aiola, Salvatore; Akindinov, Alexander; Al-turany, Mohammad; Alam, Sk Noor; Silva De Albuquerque, Danilo; Aleksandrov, Dmitry; Alessandro, Bruno; Alfaro Molina, Jose Ruben; Ali, Yasir; Alici, Andrea; Alkin, Anton; Alme, Johan; Alt, Torsten; Altenkamper, Lucas; Altsybeev, Igor; Anaam, Mustafa Naji; Andrei, Cristian; Andreou, Dimitra; Andrews, Harry Arthur; Andronic, Anton; Angeletti, Massimo; Anguelov, Venelin; Anson, Christopher Daniel; Anticic, Tome; Antinori, Federico; Antonioli, Pietro; Anwar, Rafay; Apadula, Nicole; Aphecetche, Laurent Bernard; Appelshaeuser, Harald; Arcelli, Silvia; Arnaldi, Roberta; Arnold, Oliver Werner; Arsene, Ionut Cristian; Arslandok, Mesut; Audurier, Benjamin; Augustinus, Andre; Averbeck, Ralf Peter; Azmi, Mohd Danish; Badala, Angela; Baek, Yong Wook; Bagnasco, Stefano; Bailhache, Raphaelle Marie; Bala, Renu; Baldisseri, Alberto; Ball, Markus; Baral, Rama Chandra; Barbano, Anastasia Maria; Barbera, Roberto; Barile, Francesco; Barioglio, Luca; Barnafoldi, Gergely Gabor; Barnby, Lee Stuart; Ramillien Barret, Valerie; Bartalini, Paolo; Barth, Klaus; Bartsch, Esther; Bastid, Nicole; Basu, Sumit; Batigne, Guillaume; Batyunya, Boris; Batzing, Paul Christoph; Bazo Alba, Jose Luis; Bearden, Ian Gardner; Beck, Hans; Bedda, Cristina; Behera, Nirbhay Kumar; Belikov, Iouri; Bellini, Francesca; Bello Martinez, Hector; Bellwied, Rene; Espinoza Beltran, Lucina Gabriela; Belyaev, Vladimir; Bencedi, Gyula; Beole, Stefania; Bercuci, Alexandru; Berdnikov, Yaroslav; Berenyi, Daniel; Bertens, Redmer Alexander; Berzano, Dario; Betev, Latchezar; Bhaduri, Partha Pratim; Bhasin, Anju; Bhat, Inayat Rasool; Bhatt, Himani; Bhattacharjee, Buddhadeb; Bhom, Jihyun; Bianchi, Antonio; Bianchi, Livio; Bianchi, Nicola; Bielcik, Jaroslav; Bielcikova, Jana; Bilandzic, Ante; Biro, Gabor; Biswas, Rathijit; Biswas, Saikat; Blair, Justin Thomas; Blau, Dmitry; Blume, Christoph; Boca, Gianluigi; Bock, Friederike; Bogdanov, Alexey; Boldizsar, Laszlo; Bombara, Marek; Bonomi, Germano; Bonora, Matthias; Borel, Herve; Borissov, Alexander; Borri, Marcello; Botta, Elena; Bourjau, Christian; Bratrud, Lars; Braun-munzinger, Peter; Bregant, Marco; Broker, Theo Alexander; Broz, Michal; Brucken, Erik Jens; Bruna, Elena; Bruno, Giuseppe Eugenio; Budnikov, Dmitry; Buesching, Henner; Bufalino, Stefania; Buhler, Paul; Buncic, Predrag; Busch, Oliver; Buthelezi, Edith Zinhle; Bashir Butt, Jamila; Buxton, Jesse Thomas; Cabala, Jan; Caffarri, Davide; Caines, Helen Louise; Caliva, Alberto; Calvo Villar, Ernesto; Soto Camacho, Rabi; Camerini, Paolo; Capon, Aaron Allan; Carena, Francesco; Carena, Wisla; Carnesecchi, Francesca; Castillo Castellanos, Javier Ernesto; Castro, Andrew John; Casula, Ester Anna Rita; Ceballos Sanchez, Cesar; Chandra, Sinjini; Chang, Beomsu; Chang, Wan; Chapeland, Sylvain; Chartier, Marielle; Chattopadhyay, Subhasis; Chattopadhyay, Sukalyan; Chauvin, Alex; Cheshkov, Cvetan Valeriev; Cheynis, Brigitte; Chibante Barroso, Vasco Miguel; Dobrigkeit Chinellato, David; Cho, Soyeon; Chochula, Peter; Chowdhury, Tasnuva; Christakoglou, Panagiotis; Christensen, Christian Holm; Christiansen, Peter; Chujo, Tatsuya; Chung, Suh-urk; Cicalo, Corrado; Cifarelli, Luisa; Cindolo, Federico; Cleymans, Jean Willy Andre; Colamaria, Fabio Filippo; Colella, Domenico; Collu, Alberto; Colocci, Manuel; Concas, Matteo; Conesa Balbastre, Gustavo; Conesa Del Valle, Zaida; Contreras Nuno, Jesus Guillermo; Cormier, Thomas Michael; Corrales Morales, Yasser; Cortese, Pietro; Cosentino, Mauro Rogerio; Costa, Filippo; Costanza, Susanna; Crkovska, Jana; Crochet, Philippe; Cuautle Flores, Eleazar; Cunqueiro Mendez, Leticia; Dahms, Torsten; Dainese, Andrea; Dani, Sanskruti; Danisch, Meike Charlotte; Danu, Andrea; Das, Debasish; Das, Indranil; Das, Supriya; Dash, Ajay Kumar; Dash, Sadhana; De, Sudipan; De Caro, Annalisa; De Cataldo, Giacinto; De Conti, Camila; De Cuveland, Jan; De Falco, Alessandro; De Gruttola, Daniele; De Marco, Nora; De Pasquale, Salvatore; Derradi De Souza, Rafael; Franz Degenhardt, Hermann; Deisting, Alexander; Deloff, Andrzej; Delsanto, Silvia; Deplano, Caterina; Dhankher, Preeti; Di Bari, Domenico; Di Mauro, Antonio; Di Ruzza, Benedetto; Arteche Diaz, Raul; Dietel, Thomas; Dillenseger, Pascal; Ding, Yanchun; Divia, Roberto; Djuvsland, Oeystein; Dobrin, Alexandru Florin; Domenicis Gimenez, Diogenes; Donigus, Benjamin; Dordic, Olja; Van Doremalen, Lennart Vincent; Dubey, Anand Kumar; Dubla, Andrea; Ducroux, Laurent; Dudi, Sandeep; Duggal, Ashpreet Kaur; Dukhishyam, Mallick; Dupieux, Pascal; Ehlers Iii, Raymond James; Elia, Domenico; Endress, Eric; Engel, Heiko; Epple, Eliane; Erazmus, Barbara Ewa; Erhardt, Filip; Ersdal, Magnus Rentsch; Espagnon, Bruno; Eulisse, Giulio; Eum, Jongsik; Evans, David; Evdokimov, Sergey; Fabbietti, Laura; Faggin, Mattia; Faivre, Julien; Fantoni, Alessandra; Fasel, Markus; Feldkamp, Linus; Feliciello, Alessandro; Feofilov, Grigorii; Fernandez Tellez, Arturo; Ferretti, Alessandro; Festanti, Andrea; Feuillard, Victor Jose Gaston; Figiel, Jan; Araujo Silva Figueredo, Marcel; Filchagin, Sergey; Finogeev, Dmitry; Fionda, Fiorella; Fiorenza, Gabriele; Flor, Fernando; Floris, Michele; Foertsch, Siegfried Valentin; Foka, Panagiota; Fokin, Sergey; Fragiacomo, Enrico; Francescon, Andrea; Francisco, Audrey; Frankenfeld, Ulrich Michael; Fronze, Gabriele Gaetano; Fuchs, Ulrich; Furget, Christophe; Furs, Artur; Fusco Girard, Mario; Gaardhoeje, Jens Joergen; Gagliardi, Martino; Gago Medina, Alberto Martin; Gajdosova, Katarina; Gallio, Mauro; Duarte Galvan, Carlos; Ganoti, Paraskevi; Garabatos Cuadrado, Jose; Garcia-solis, Edmundo Javier; Garg, Kunal; Gargiulo, Corrado; Gasik, Piotr Jan; Gauger, Erin Frances; De Leone Gay, Maria Beatriz; Germain, Marie; Ghosh, Jhuma; Ghosh, Premomoy; Ghosh, Sanjay Kumar; Gianotti, Paola; Giubellino, Paolo; Giubilato, Piero; Glassel, Peter; Gomez Coral, Diego Mauricio; Gomez Ramirez, Andres; Gonzalez, Victor; Gonzalez Zamora, Pedro; Gorbunov, Sergey; Gorlich, Lidia Maria; Gotovac, Sven; Grabski, Varlen; Graczykowski, Lukasz Kamil; Graham, Katie Leanne; Greiner, Leo Clifford; Grelli, Alessandro; Grigoras, Costin; Grigoryev, Vladislav; Grigoryan, Ara; Grigoryan, Smbat; Gronefeld, Julius Maximilian; Grosa, Fabrizio; Grosse-oetringhaus, Jan Fiete; Grosso, Raffaele; Guernane, Rachid; Guerzoni, Barbara; Guittiere, Manuel; Gulbrandsen, Kristjan Herlache; Gunji, Taku; Gupta, Anik; Gupta, Ramni; Bautista Guzman, Irais; Haake, Rudiger; Habib, Michael Karim; Hadjidakis, Cynthia Marie; Hamagaki, Hideki; Hamar, Gergoe; Hamid, Mohammed; Hamon, Julien Charles; Hannigan, Ryan; Haque, Md Rihan; Harris, John William; Harton, Austin Vincent; Hassan, Hadi; Hatzifotiadou, Despina; Hayashi, Shinichi; Heckel, Stefan Thomas; Hellbar, Ernst; Helstrup, Haavard; Herghelegiu, Andrei Ionut; Gonzalez Hernandez, Emma; Herrera Corral, Gerardo Antonio; Herrmann, Florian; Hetland, Kristin Fanebust; Hilden, Timo Eero; Hillemanns, Hartmut; Hills, Christopher; Hippolyte, Boris; Hohlweger, Bernhard; Horak, David; Hornung, Sebastian; Hosokawa, Ritsuya; Hota, Jyotishree; Hristov, Peter Zahariev; Huang, Chun-lu; Hughes, Charles; Huhn, Patrick; Humanic, Thomas; Hushnud, Hushnud; Hussain, Nur; Hussain, Tahir; Hutter, Dirk; Hwang, Dae Sung; Iddon, James Philip; Iga Buitron, Sergio Arturo; Ilkaev, Radiy; Inaba, Motoi; Ippolitov, Mikhail; Islam, Md Samsul; Ivanov, Marian; Ivanov, Vladimir; Izucheev, Vladimir; Jacak, Barbara; Jacazio, Nicolo; Jacobs, Peter Martin; Jadhav, Manoj Bhanudas; Jadlovska, Slavka; Jadlovsky, Jan; Jaelani, Syaefudin; Jahnke, Cristiane; Jakubowska, Monika Joanna; Janik, Malgorzata Anna; Jena, Chitrasen; Jercic, Marko; Jevons, Oliver; Jimenez Bustamante, Raul Tonatiuh; Jin, Muqing; Jones, Peter Graham; Jusko, Anton; Kalinak, Peter; Kalweit, Alexander Philipp; Kang, Ju Hwan; Kaplin, Vladimir; Kar, Somnath; Karasu Uysal, Ayben; Karavichev, Oleg; Karavicheva, Tatiana; Karczmarczyk, Przemyslaw; Karpechev, Evgeny; Kebschull, Udo Wolfgang; Keidel, Ralf; Keijdener, Darius Laurens; Keil, Markus; Ketzer, Bernhard Franz; Khabanova, Zhanna; Khan, Ahsan Mehmood; Khan, Shaista; Khan, Shuaib Ahmad; Khanzadeev, Alexei; Kharlov, Yury; Khatun, Anisa; Khuntia, Arvind; Kielbowicz, Miroslaw Marek; Kileng, Bjarte; Kim, Byungchul; Kim, Daehyeok; Kim, Dong Jo; Kim, Eun Joo; Kim, Hyeonjoong; Kim, Jinsook; Kim, Jiyoung; Kim, Minjung; Kim, Se Yong; Kim, Taejun; Kim, Taesoo; Kirsch, Stefan; Kisel, Ivan; Kiselev, Sergey; Kisiel, Adam Ryszard; Klay, Jennifer Lynn; Klein, Carsten; Klein, Jochen; Klein-boesing, Christian; Klewin, Sebastian; Kluge, Alexander; Knichel, Michael Linus; Knospe, Anders Garritt; Kobdaj, Chinorat; Varga-kofarago, Monika; Kohler, Markus Konrad; Kollegger, Thorsten; Kondratyeva, Natalia; Kondratyuk, Evgeny; Konevskikh, Artem; Konyushikhin, Maxim; Kovalenko, Oleksandr; Kovalenko, Vladimir; Kowalski, Marek; Kralik, Ivan; Kravcakova, Adela; Kreis, Lukas; Krivda, Marian; Krizek, Filip; Kruger, Mario; Kryshen, Evgeny; Krzewicki, Mikolaj; Kubera, Andrew Michael; Kucera, Vit; Kuhn, Christian Claude; Kuijer, Paulus Gerardus; Kumar, Jitendra; Kumar, Lokesh; Kumar, Shyam; Kundu, Sourav; Kurashvili, Podist; Kurepin, Alexander; Kurepin, Alexey; Kuryakin, Alexey; Kushpil, Svetlana; Kvapil, Jakub; Kweon, Min Jung; Kwon, Youngil; La Pointe, Sarah Louise; La Rocca, Paola; Lai, Yue Shi; Lakomov, Igor; Langoy, Rune; Lapidus, Kirill; Lara Martinez, Camilo Ernesto; Lardeux, Antoine Xavier; Larionov, Pavel; Laudi, Elisa; Lavicka, Roman; Lea, Ramona; Leardini, Lucia; Lee, Seongjoo; Lehas, Fatiha; Lehner, Sebastian; Lehrbach, Johannes; Lemmon, Roy Crawford; Leon Monzon, Ildefonso; Levai, Peter; Li, Xiaomei; Li, Xing Long; Lien, Jorgen Andre; Lietava, Roman; Lim, Bong-hwi; Lindal, Svein; Lindenstruth, Volker; Lindsay, Scott William; Lippmann, Christian; Lisa, Michael Annan; Litichevskyi, Vladyslav; Liu, Alwina; Ljunggren, Hans Martin; Llope, William; Lodato, Davide Francesco; Loginov, Vitaly; Loizides, Constantinos; Loncar, Petra; Lopez, Xavier Bernard; Lopez Torres, Ernesto; Lowe, Andrew John; Luettig, Philipp Johannes; Luhder, Jens Robert; Lunardon, Marcello; Luparello, Grazia; Lupi, Matteo; Maevskaya, Alla; Mager, Magnus; Mahmood, Sohail Musa; Maire, Antonin; Majka, Richard Daniel; Malaev, Mikhail; Malik, Qasim Waheed; Malinina, Liudmila; Mal'kevich, Dmitry; Malzacher, Peter; Mamonov, Alexander; Manko, Vladislav; Manso, Franck; Manzari, Vito; Mao, Yaxian; Marchisone, Massimiliano; Mares, Jiri; Margagliotti, Giacomo Vito; Margotti, Anselmo; Margutti, Jacopo; Marin, Ana Maria; Markert, Christina; Marquard, Marco; Martin, Nicole Alice; Martinengo, Paolo; Martinez, Jacobb Lee; Martinez Hernandez, Mario Ivan; Martinez-garcia, Gines; Martinez Pedreira, Miguel; Masciocchi, Silvia; Masera, Massimo; Masoni, Alberto; Massacrier, Laure Marie; Masson, Erwann; Mastroserio, Annalisa; Mathis, Andreas Michael; Toledo Matuoka, Paula Fernanda; Matyja, Adam Tomasz; Mayer, Christoph; Mazzilli, Marianna; Mazzoni, Alessandra Maria; Meddi, Franco; Melikyan, Yuri; Menchaca-rocha, Arturo Alejandro; Meninno, Elisa; Mercado-perez, Jorge; Meres, Michal; Soncco Meza, Carlos; Mhlanga, Sibaliso; Miake, Yasuo; Micheletti, Luca; Mieskolainen, Matti Mikael; Mihaylov, Dimitar Lubomirov; Mikhaylov, Konstantin; Mischke, Andre; Mishra, Aditya Nath; Miskowiec, Dariusz Czeslaw; Mitra, Jubin; Mitu, Ciprian Mihai; Mohammadi, Naghmeh; Mohanty, Auro Prasad; Mohanty, Bedangadas; Khan, Mohammed Mohisin; Moreira De Godoy, Denise Aparecida; Perez Moreno, Luis Alberto; Moretto, Sandra; Morreale, Astrid; Morsch, Andreas; Muccifora, Valeria; Mudnic, Eugen; Muhlheim, Daniel Michael; Muhuri, Sanjib; Mukherjee, Maitreyee; Mulligan, James Declan; Gameiro Munhoz, Marcelo; Munning, Konstantin; Arratia Munoz, Miguel Ignacio; Munzer, Robert Helmut; Murakami, Hikari; Murray, Sean; Musa, Luciano; Musinsky, Jan; Myers, Corey James; Myrcha, Julian Wojciech; Naik, Bharati; Nair, Rahul; Nandi, Basanta Kumar; Nania, Rosario; Nappi, Eugenio; Narayan, Amrendra; Naru, Muhammad Umair; Nassirpour, Adrian Fereydon; Ferreira Natal Da Luz, Pedro Hugo; Nattrass, Christine; Rosado Navarro, Sebastian; Nayak, Kishora; Nayak, Ranjit; Nayak, Tapan Kumar; Nazarenko, Sergey; Negrao De Oliveira, Renato Aparecido; Nellen, Lukas; Nesbo, Simon Voigt; Neskovic, Gvozden; Ng, Fabian; Nicassio, Maria; Niedziela, Jeremi; Nielsen, Borge Svane; Nikolaev, Sergey; Nikulin, Sergey; Nikulin, Vladimir; Noferini, Francesco; Nomokonov, Petr; Nooren, Gerardus; Cabanillas Noris, Juan Carlos; Norman, Jaime; Nyanin, Alexander; Nystrand, Joakim Ingemar; Oh, Hoonjung; Ohlson, Alice Elisabeth; Oleniacz, Janusz; Oliveira Da Silva, Antonio Carlos; Oliver, Michael Henry; Onderwaater, Jacobus; Oppedisano, Chiara; Orava, Risto; Oravec, Matej; Ortiz Velasquez, Antonio; Oskarsson, Anders Nils Erik; Otwinowski, Jacek Tomasz; Oyama, Ken; Pachmayer, Yvonne Chiara; Pacik, Vojtech; Pagano, Davide; Paic, Guy; Palni, Prabhakar; Pan, Jinjin; Pandey, Ashutosh Kumar; Panebianco, Stefano; Papikyan, Vardanush; Pareek, Pooja; Park, Jonghan; Parkkila, Jasper Elias; Parmar, Sonia; Passfeld, Annika; Pathak, Surya Prakash; Patra, Rajendra Nath; Paul, Biswarup; Pei, Hua; Peitzmann, Thomas; Peng, Xinye; Pereira, Luis Gustavo; Pereira Da Costa, Hugo Denis Antonio; Peresunko, Dmitry Yurevich; Perez Lezama, Edgar; Peskov, Vladimir; Pestov, Yury; Petracek, Vojtech; Petrovici, Mihai; Petta, Catia; Peretti Pezzi, Rafael; Piano, Stefano; Pikna, Miroslav; Pillot, Philippe; Ozelin De Lima Pimentel, Lais; Pinazza, Ombretta; Pinsky, Lawrence; Pisano, Silvia; Piyarathna, Danthasinghe; Ploskon, Mateusz Andrzej; Planinic, Mirko; Pliquett, Fabian; Pluta, Jan Marian; Pochybova, Sona; Podesta Lerma, Pedro Luis Manuel; Poghosyan, Martin; Polishchuk, Boris; Poljak, Nikola; Poonsawat, Wanchaloem; Pop, Amalia; Poppenborg, Hendrik; Porteboeuf, Sarah Julie; Pozdniakov, Valeriy; Prasad, Sidharth Kumar; Preghenella, Roberto; Prino, Francesco; Pruneau, Claude Andre; Pshenichnov, Igor; Puccio, Maximiliano; Punin, Valery; Putschke, Jorn Henning; Raha, Sibaji; Rajput, Sonia; Rak, Jan; Rakotozafindrabe, Andry Malala; Ramello, Luciano; Rami, Fouad; Raniwala, Rashmi; Raniwala, Sudhir; Rasanen, Sami Sakari; Rascanu, Bogdan Theodor; Ratza, Viktor; Ravasenga, Ivan; Read, Kenneth Francis; Redlich, Krzysztof; Rehman, Attiq Ur; Reichelt, Patrick Simon; Reidt, Felix; Ren, Xiaowen; Renfordt, Rainer Arno Ernst; Reshetin, Andrey; Revol, Jean-pierre; Reygers, Klaus Johannes; Riabov, Viktor; Richert, Tuva Ora Herenui; Richter, Matthias Rudolph; Riedler, Petra; Riegler, Werner; Riggi, Francesco; Ristea, Catalin-lucian; Rode, Sudhir Pandurang; Rodriguez Cahuantzi, Mario; Roeed, Ketil; Rogalev, Roman; Rogochaya, Elena; Rohr, David Michael; Roehrich, Dieter; Rokita, Przemyslaw Stefan; Ronchetti, Federico; Dominguez Rosas, Edgar; Roslon, Krystian; Rosnet, Philippe; Rossi, Andrea; Rotondi, Alberto; Roukoutakis, Filimon; Roy, Christelle Sophie; Roy, Pradip Kumar; Vazquez Rueda, Omar; Rui, Rinaldo; Rumyantsev, Boris; Rustamov, Anar; Ryabinkin, Evgeny; Ryabov, Yury; Rybicki, Andrzej; Saarinen, Sampo; Sadhu, Samrangy; Sadovskiy, Sergey; Safarik, Karel; Saha, Sumit Kumar; Sahoo, Baidyanath; Sahoo, Pragati; Sahoo, Raghunath; Sahoo, Sarita; Sahu, Pradip Kumar; Saini, Jogender; Sakai, Shingo; Saleh, Mohammad Ahmad; Sambyal, Sanjeev Singh; Samsonov, Vladimir; Sandoval, Andres; Sarkar, Amal; Sarkar, Debojit; Sarkar, Nachiketa; Sarma, Pranjal; Sas, Mike Henry Petrus; Scapparone, Eugenio; Scarlassara, Fernando; Schaefer, Brennan; Scheid, Horst Sebastian; Schiaua, Claudiu Cornel; Schicker, Rainer Martin; Schmidt, Christian Joachim; Schmidt, Hans Rudolf; Schmidt, Marten Ole; Schmidt, Martin; Schmidt, Nicolas Vincent; Schukraft, Jurgen; Schutz, Yves Roland; Schwarz, Kilian Eberhard; Schweda, Kai Oliver; Scioli, Gilda; Scomparin, Enrico; Sefcik, Michal; Seger, Janet Elizabeth; Sekiguchi, Yuko; Sekihata, Daiki; Selyuzhenkov, Ilya; Senosi, Kgotlaesele; Senyukov, Serhiy; Serradilla Rodriguez, Eulogio; Sett, Priyanka; Sevcenco, Adrian; Shabanov, Arseniy; Shabetai, Alexandre; Shahoyan, Ruben; Shaikh, Wadut; Shangaraev, Artem; Sharma, Anjali; Sharma, Ankita; Sharma, Meenakshi; Sharma, Natasha; Sheikh, Ashik Ikbal; Shigaki, Kenta; Shimomura, Maya; Shirinkin, Sergey; Shou, Qiye; Shtejer Diaz, Katherin; Sibiryak, Yury; Siddhanta, Sabyasachi; Sielewicz, Krzysztof Marek; Siemiarczuk, Teodor; Silvermyr, David Olle Rickard; Simatovic, Goran; Simonetti, Giuseppe; Singaraju, Rama Narayana; Singh, Ranbir; Singh, Randhir; Singhal, Vikas; Sarkar - Sinha, Tinku; Sitar, Branislav; Sitta, Mario; Skaali, Bernhard; Slupecki, Maciej; Smirnov, Nikolai; Snellings, Raimond; Snellman, Tomas Wilhelm; Song, Jihye; Soramel, Francesca; Sorensen, Soren Pontoppidan; Sozzi, Federica; Sputowska, Iwona Anna; Stachel, Johanna; Stan, Ionel; Stankus, Paul; Stenlund, Evert Anders; Stocco, Diego; Storetvedt, Maksim Melnik; Strmen, Peter; Alarcon Do Passo Suaide, Alexandre; Sugitate, Toru; Suire, Christophe Pierre; Suleymanov, Mais Kazim Oglu; Suljic, Miljenko; Sultanov, Rishat; Sumbera, Michal; Sumowidagdo, Suharyo; Suzuki, Ken; Swain, Sagarika; Szabo, Alexander; Szarka, Imrich; Tabassam, Uzma; Takahashi, Jun; Tambave, Ganesh Jagannath; Tanaka, Naoto; Tarhini, Mohamad; Tariq, Mohammad; Tarzila, Madalina-gabriela; Tauro, Arturo; Tejeda Munoz, Guillermo; Telesca, Adriana; Terrevoli, Cristina; Teyssier, Boris; Thakur, Dhananjaya; Thakur, Sanchari; Thomas, Deepa; Thoresen, Freja; Tieulent, Raphael Noel; Tikhonov, Anatoly; Timmins, Anthony Robert; Toia, Alberica; Topilskaya, Nataliya; Toppi, Marco; Rojas Torres, Solangel; Tripathy, Sushanta; Trogolo, Stefano; Trombetta, Giuseppe; Tropp, Lukas; Trubnikov, Victor; Trzaska, Wladyslaw Henryk; Trzcinski, Tomasz Piotr; Trzeciak, Barbara Antonina; Tsuji, Tomoya; Tumkin, Alexandr; Turrisi, Rosario; Tveter, Trine Spedstad; Ullaland, Kjetil; Umaka, Ejiro Naomi; Uras, Antonio; Usai, Gianluca; Utrobicic, Antonija; Vala, Martin; Van Hoorne, Jacobus Willem; Van Leeuwen, Marco; Vande Vyvre, Pierre; Varga, Dezso; Diozcora Vargas Trevino, Aurora; Vargyas, Marton; Varma, Raghava; Vasileiou, Maria; Vasiliev, Andrey; Vauthier, Astrid; Vazquez Doce, Oton; Vechernin, Vladimir; Veen, Annelies Marianne; Vercellin, Ermanno; Vergara Limon, Sergio; Vermunt, Luuk; Vernet, Renaud; Vertesi, Robert; Vickovic, Linda; Viinikainen, Jussi Samuli; Vilakazi, Zabulon; Villalobos Baillie, Orlando; Villatoro Tello, Abraham; Vinogradov, Alexander; Virgili, Tiziano; Vislavicius, Vytautas; Vodopyanov, Alexander; Volkl, Martin Andreas; Voloshin, Kirill; Voloshin, Sergey; Volpe, Giacomo; Von Haller, Barthelemy; Vorobyev, Ivan; Voscek, Dominik; Vranic, Danilo; Vrlakova, Janka; Wagner, Boris; Wang, Hongkai; Wang, Mengliang; Watanabe, Yosuke; Weber, Michael; Weber, Steffen Georg; Wegrzynek, Adam; Weiser, Dennis Franz; Wenzel, Sandro Christian; Wessels, Johannes Peter; Westerhoff, Uwe; Whitehead, Andile Mothegi; Wiechula, Jens; Wikne, Jon; Wilk, Grzegorz Andrzej; Wilkinson, Jeremy John; Willems, Guido Alexander; Williams, Crispin; Willsher, Emily; Windelband, Bernd Stefan; Witt, William Edward; Xu, Ran; Yalcin, Serpil; Yamakawa, Kosei; Yano, Satoshi; Yin, Zhongbao; Yokoyama, Hiroki; Yoo, In-kwon; Yoon, Jin Hee; Yurchenko, Volodymyr; Zaccolo, Valentina; Zaman, Ali; Zampolli, Chiara; Correa Zanoli, Henrique Jose; Zardoshti, Nima; Zarochentsev, Andrey; Zavada, Petr; Zavyalov, Nikolay; Zbroszczyk, Hanna Paulina; Zhalov, Mikhail; Zhang, Xiaoming; Zhang, Yonghong; Zhang, Zuman; Zhao, Chengxin; Zherebchevskii, Vladimir; Zhigareva, Natalia; Zhou, Daicui; Zhou, You; Zhou, Zhuo; Zhu, Hongsheng; Zhu, Jianhui; Zhu, Ya; Zichichi, Antonino; Zimmermann, Markus Bernhard; Zinovjev, Gennady; Zmeskal, Johann; Zou, Shuguang

    2018-01-01

    The first measurements of anisotropic flow coefficients $v_{n}$ for mid-rapidity charged particles in Xe-Xe collisions at $\\sqrt{s_{NN}}=5.44$ TeV are presented. Comparing these measurements to those from Pb-Pb collisions at $\\sqrt{s_{NN}}=5.02$ TeV, $v_{2}$ is found to be suppressed for mid-central collisions at the same centrality, and enhanced for central collisions. The values of $v_{3}$ are generally larger in Xe-Xe than in Pb-Pb at a given centrality. These observations are consistent with expectations from hydrodynamic predictions. When both $v_{2}$ and $v_{3}$ are divided by their corresponding eccentricities for a variety of initial state models, they generally scale with transverse density when comparing Xe-Xe and Pb-Pb, with some deviations observed in central Xe-Xe and Pb-Pb collisions. These results assist in placing strong constraints on both the initial state geometry and medium response for relativistic heavy-ion collisions.

  5. The 4s- and 4p- XPS spectra of Xe, XeF2 and XeF4

    International Nuclear Information System (INIS)

    Ohno, Masahide

    2003-01-01

    The 4s- and 4p- XPS spectra of Xe gas, XeF 2 molecule and XeF 4 molecule are calculated by an ab-initio atomic many-body theory. The 4s-peak and the prominent '4p'-peak are predicted well by the present theory. In XeF 2 and XeF 4 the spectral lines observed below the 4d-double ionization threshold are the 4d -2 4f multiplet states strongly perturbed by the interaction with the initial 4p 1/2 -hole state. They are very similar to the spectral lines which emerge with an increase in atomic number (e.g. Ba)

  6. FLIP for FLAG model visualization

    Energy Technology Data Exchange (ETDEWEB)

    Wooten, Hasani Omar [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-15

    A graphical user interface has been developed for FLAG users. FLIP (FLAG Input deck Parser) provides users with an organized view of FLAG models and a means for efficiently and easily navigating and editing nodes, parameters, and variables.

  7. Determination of 131mXe and 133mXe in the presence of 133gXe via combined beta-spectroscopy and delayed coincidence

    International Nuclear Information System (INIS)

    Reeder, P.L.; Bowyer, T.W.; McIntyre, J.I.; Pitts, W.K.

    2001-01-01

    The International Monitoring System for the Comprehensive Nuclear-Test-Ban Treaty will include measurements of Xe fission products. Pacific Northwest National Laboratory has developed an automated system for separating Xe from air which detects Xe fission products using a beta-gamma counting system for 131m Xe, 133m Xe, 133g Xe, and 135g Xe. Betas and conversion electrons are detected in a plastic scintillation cell containing the Xe sample. Gamma and X-rays are detected in a NaI(Tl) scintillation detector which surrounds the plastic scintillator sample cell. Two-dimensional pulse-height spectra of gamma-energy versus beta-energy are obtained. The plastic scintillator spectrum in coincidence with the 31-keV X-rays from 131m Xe. 133m Xe, and 133g Xe is a complex mixture of conversion electrons and betas. A new technique to simultaneously measure the delayed coincidence (T 1/2 = 6.27 ns) between beta-particles from 133g Xe and conversion electrons depopulating the 81-keV state in 133 Cs is being developed. This technique allows separation of the 133g Xe beta spectrum from the conversion electrons due to 131m Xe and 133m Xe and uniquely quantifies all three nuclides. (author)

  8. Determination of 131m Xe and 133m Xe in the presence of 133gXe via combined beta-spectroscopy and delayed coincidence

    International Nuclear Information System (INIS)

    Reeder, Paul L.; Bowyer, Ted W.; McIntyre, Justin I.; Pitts, W K.

    2001-01-01

    The International Monitoring System for the Comprehensive Nuclear-Test-Ban Treaty will include measurements of Xe fission products. Pacific Northwest National Laboratory has developed an automated system for separating Xe from air which detects Xe fission products using a beta-gamma counting system for 131mXe, 133mXe, 133Xe, and 135Xe. Betas and conversion electrons are detected in a plastic scintillation cell containing the Xe sample. Gamma and X-rays are detected in a NaI(Tl) scintillation detector which surrounds the plastic scintillator sample cell. Two-dimensional pulse height spectra of gamma energy versus beta energy are obtained. The plastic scintillator spectrum in coincidence with the 31-keV X-rays from 131mXe. 133mXe, and 133Xe is a complex mixture of conversion electrons and betas. A new technique to simultaneously measure the delayed coincidence (t1/2 = 6.27 ns) between beta particles from 133Xe and conversion electrons depopulating the 81-keV state in 133Cs is being developed. This technique will allow separation of the 133Xe spectrum from the conversion electrons due to 131mXe and 133mXe and will uniquely quantify all three nuclides

  9. 75 FR 34309 - Flag Day and National Flag Week, 2010

    Science.gov (United States)

    2010-06-16

    ... Nation to confront tyranny and oppression still flies today as an unequivocal emblem of freedom and... gatherings to private memorials, we gathered to salute our flag, and in doing so, renewed the eternal promise... recognize the American flag as a symbol of hope and inspiration to people at home and around the world--as a...

  10. Low-lying levels of 129Xe and 131Xe

    International Nuclear Information System (INIS)

    Palmer, D.C.; Irving, A.D.; Forsyth, P.D.; Hall, I.; Martin, D.G.E.; Maynard, M.J.

    1978-01-01

    The nuclei 129 Xe and 131 Xe have been studied by Coulomb excitation and by (α, n) reactions on 126 Te and 128 Te. Eleven new levels for 129 Xe and six for 131 Xe and B(E2) transition values for some of the low-lying states are reported. The present Coulomb excitation experiments together with published β-decay work enable some spin-parity assignments and restrictions to be made. The data are broadly consistent with the predictions of the particle-vibrator coupling model, although a thorough comparison requires further spectroscopic measurements and more detailed theoretical calculation. (author)

  11. On national flags and language tags: Effects of flag-language congruency in bilingual word recognition.

    Science.gov (United States)

    Grainger, Jonathan; Declerck, Mathieu; Marzouki, Yousri

    2017-07-01

    French-English bilinguals performed a generalized lexical decision experiment with mixed lists of French and English words and pseudo-words. In Experiment 1, each word/pseudo-word was superimposed on the picture of the French or UK flag, and flag-word congruency was manipulated. The flag was not informative with respect to either the lexical decision response or the language of the word. Nevertheless, lexical decisions to word stimuli were faster following the congruent flag compared with the incongruent flag, but only for French (L1) words. Experiment 2 replicated this flag-language congruency effect in a priming paradigm, where the word and pseudo-word targets followed the brief presentation of the flag prime, and this time effects were seen in both languages. We take these findings as evidence for a mechanism that automatically processes linguistic and non-linguistic information concerning the presence or not of a given language. Language membership information can then modulate lexical processing, in line with the architecture of the BIA model, but not the BIA+ model. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Hydrodynamic predictions for 5.44 TeV Xe+Xe collisions

    Science.gov (United States)

    Giacalone, Giuliano; Noronha-Hostler, Jacquelyn; Luzum, Matthew; Ollitrault, Jean-Yves

    2018-03-01

    We argue that relativistic hydrodynamics is able to make robust predictions for soft particle production in Xe+Xe collisions at the CERN Large Hadron Collider (LHC). The change of system size from Pb+Pb to Xe+Xe provides a unique opportunity to test the scaling laws inherent to fluid dynamics. Using event-by-event hydrodynamic simulations, we make quantitative predictions for several observables: mean transverse momentum, anisotropic flow coefficients, and their fluctuations. Results are shown as a function of collision centrality.

  13. Romania's flag raised at CERN

    CERN Multimedia

    Corinne Pralavorio

    2016-01-01

    A ceremony was held for the raising of the Romanian flag alongside the flags of CERN’s 21 other Member States.   The Romanian flag is raised alongside the flags of CERN’s other Member States, in the presence of the Romanian President, CERN’s Director-General, the President of the CERN Council and a large Romanian delegation. (Image: Maximilien Brice/ Sophia Bennett/CERN) On Monday, 5 September, the Romanian flag was raised in front of CERN for the first time, marking the country’s accession to Membership of the Organization. The blue, yellow and red flag joined those of the other 21 Member States of CERN in a ceremony attended by the President of Romania, Klaus Iohannis, the Romanian Minister for Education and Scientific Research, Mircea Dumitru, and several other members of the President’s office, the government and academia in Romania. The country officially became a CERN Member State on 17 July 2016, after 25 years of collaboration between the...

  14. Symmetric resonance double charge transfer in Kr++ + Kr and Xe++ + Xe systems

    International Nuclear Information System (INIS)

    Okuno, K.; Koizumi, T.; Kaneko, Y.

    1978-01-01

    Cross sections of processes Kr ++ + Kr → Ke + Kr ++ and Xe ++ + XeXe + Xe ++ were measured by the injected-ion-drift-tube technique from 0.04 to 20 eV. For both cases, the cross section below 1 eV coincides with the orbiting cross sections with a charge-transfer probability 1/2. Above 1 eV, the energy dependence of the cross sectcion is like that for single charge transfer. Mobilities of Kr ++ and Xe ++ in He are presented also

  15. Inner-shell photoionization and core-hole decay of Xe and XeF2.

    Science.gov (United States)

    Southworth, Stephen H; Wehlitz, Ralf; Picón, Antonio; Lehmann, C Stefan; Cheng, Lan; Stanton, John F

    2015-06-14

    Photoionization cross sections and partial ion yields of Xe and XeF2 from Xe 3d(5/2), Xe 3d(3/2), and F 1s subshells in the 660-740 eV range are compared to explore effects of the F ligands. The Xe 3d-ϵf continuum shape resonances dominate the photoionization cross sections of both the atom and molecule, but prominent resonances appear in the XeF2 cross section due to nominal excitation of Xe 3d and F 1s electrons to the lowest unoccupied molecular orbital (LUMO), a delocalized anti-bonding MO. Comparisons of the ion products from the atom and molecule following Xe 3d photoionization show that the charge-state distribution of Xe ions is shifted to lower charge states in the molecule along with production of energetic F(+) and F(2+) ions. This suggests that, in decay of a Xe 3d core hole, charge is redistributed to the F ligands and the system dissociates due to Coulomb repulsion. The ion products from excitation of the F 1s-LUMO resonance are different and show strong increases in the yields of Xe(+) and F(+) ions. The subshell ionization thresholds, the LUMO resonance energies, and their oscillator strengths are calculated by relativistic coupled-cluster methods and agree well with measurements.

  16. Comprehensive sets of 124Xe(n ,γ )125Xe and 124Xe(n ,2 n )123Xe cross-section data for assessment of inertial-confinement deuterium-tritium fusion plasma

    Science.gov (United States)

    Bhike, Megha; Fallin, B.; Gooden, M. E.; Ludin, N.; Tornow, W.

    2015-01-01

    Measurements of the neutron radiative-capture cross section of 124Xe have been performed for the first time for neutron energies above 100 keV. In addition, data for the 124Xe(n ,2 n )123Xe reaction cross section have been obtained from threshold to 14.8 MeV to cover the entire energy range of interest, while previous data existed only at around 14 MeV. The results of these measurements provide the basis for an alternative and sensitive diagnostic tool for investigating properties of the inertial confinement fusion plasma in deuterium-tritium (DT) capsules at the National Ignition Facility located at Lawrence Livermore National Laboratory. Here, areal density ρ R (density × radius) of the fuel, burn asymmetry, and fuel-ablator mix are of special interest. The 124Xe(n ,γ )125Xe reaction probes the down-scattered neutrons, while the 124Xe(n ,2 n )123Xe reaction provides a measure of the 14 MeV direct neutrons.

  17. Ab initio effective core potentials including relativistic effects. II. Potential energy curves for Xe2, Xe+2, and Xe*2

    International Nuclear Information System (INIS)

    Ermler, W.C.; Lee, Y.S.; Pitzer, K.S.; Winter, N.W.

    1978-01-01

    Potential energy curves for the ground 1 Σ + /sub g/ state of Xe 2 , the first four states of the Xe + 2 ions, and the eight Xe* 2 excimer states corresponding to the addition of a 6ssigma/sub g/ Rydberg electron to these ion cores have been computed using averaged relativistic effective core potentials (AREP) and the self-consistent field approximation for the valence electrons. The calculations were carried out using the LS-coupling scheme with the effects of spin--orbit coupling included in the resulting potential energy curves using an empirical procedure. A comparison of nonrelativistic and averaged relativistic EP's and subsequent molecular calculations indicates that relativistic effects arising from the mass--velocity and Darwin terms are not important for these properties of Xe 2 molecules. Spectroscopic constants for Xe + 2 are in good agreement with all electron CI calculations suggesting that the computed values for Xe* 2 excimers should be reliable. The lifetime for the O/sub u/ + state of the Xe 2 * is computed to be 5.6 nsec which is in the range of the experimentally determined values

  18. Hg-Xe exciplex formation in mixed Xe/Ar matrices: molecular dynamics and luminescence study.

    Science.gov (United States)

    Lozada-García, Rolando; Rojas-Lorenzo, Germán; Crépin, Claudine; Ryan, Maryanne; McCaffrey, John G

    2015-03-19

    Luminescence of Hg((3)P1) atoms trapped in mixed Ar/Xe matrices containing a small amount of Xe is reported. Broad emission bands, strongly red-shifted from absorption are recorded which are assigned to strong complexes formed between the excited mercury Hg* and xenon atoms. Molecular dynamics calculations are performed on simulated Xe/Ar samples doped with Hg to follow the behavior of Hg* in the mixed rare gas matrices leading to exciplex formation. The role of Xe atoms in the first solvation shell (SS1) around Hg was investigated in detail, revealing the formation of two kinds of triatomic exciplexes; namely, Xe-Hg*-Xe and Ar-Hg*-Xe. The first species exists only when two xenon atoms are present in SS1 with specific geometries allowing the formation of a linear or quasi-linear exciplex. In the other geometries, or in the presence of only one Xe in SS1, a linear Ar-Hg*-Xe exciplex is formed. The two kinds of exciplexes have different emission bands, the most red-shifted being that involving two Xe atoms, whose emission is very close to that observed in pure Xe matrices. Simulations give a direct access to the analysis of the experimental absorption, emission, and excitation spectra, together with the dynamics of exciplexes formation.

  19. Stark shift measurements of Xe II and Xe III spectral lines

    International Nuclear Information System (INIS)

    Cirisan, M; Pelaez, R J; Djurovic, S; Aparicio, J A; Mar, S

    2007-01-01

    Stark shift measurements of singly and doubly ionized Xe spectral lines are presented in this paper. Shifts of 110 Xe II lines and 42 Xe III lines are reported, including a significant number of new results. A low-pressure-pulsed arc with 95% of He and 5% of Xe was used as a plasma source. All measurements were performed under the following plasma conditions: electron density (0.2-1.4) x 10 23 m -3 and electron temperature 18 000-23 000 K. The measured Stark shifts are compared with other experimental and theoretical data

  20. Wavelengths and energy levels of Xe V and Xe VI obtained by collision-based spectroscopy

    International Nuclear Information System (INIS)

    Larsson, M.O.; Gonzalez, A.M.; Hallin, R.; Heijkenskjoeld, F.; Nystroem, B.; O'Sullivan, G.; Weber, C.; Waennstroem, A.

    1996-01-01

    We have utilized collision-based spectroscopy to investigate the spectra of Xe V and Xe VI. The radiation emitted following electron capture by 50 keV Xe 5+ and 60 keV Xe 6+ ions impinging on a He (Ar) gas target has been recorded in the 350-6000 (1200-2500) A wavelength region. A number of new energy levels of Xe V and Xe VI have been established from lines identified by us. In particular, we have observed and identified transitions from the 5s 2 5p4f (5s 2 4f) configuration of Xe V (Xe VI). The analysis was supported by Hartree-Fock calculations. (orig.)

  1. Excimer lasers utilizing XeF and XeCl molecules

    Energy Technology Data Exchange (ETDEWEB)

    Bychkov, Yu I; Konovalov, I N; Losev, V F; Mesyats, G A; Ryzhov, V V; Tarasenko, V F; Fedorov, A I; Shemyakina, S B; Yastremskii, A G

    1978-12-01

    The results are given of an experimental and theoretical study of XeF (wavelength approx. 350 nm) and XeCl (wavelength approx. 308 nm) lasers excited by an electron beam, a discharge stabilized by an electron beam, and a rapid discharge. These lasers are representative of ones employing halides of noble gases, which are the most powerful sources of stimulated emission in the uv region. The XeCl laser is shown to have good emission characteristics with various methods of excitation. An analysis of the kinetics of processes in the plasma of lasers utilizing halides of noble gases showed that the main channel for the transfer of the beam's energy to the formation of excimer molecules is the ionic channel. An efficiency of about 2.6 percent and a specific radiant energy of 10 J.l/sup -1/ showed that XeCl* is one of the most effective excimer molecules.

  2. 46 CFR 282.11 - Ranking of flags.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 8 2010-10-01 2010-10-01 false Ranking of flags. 282.11 Section 282.11 Shipping... COMMERCE OF THE UNITED STATES Foreign-Flag Competition § 282.11 Ranking of flags. The operators under each... priority of costs which are representative of the flag. For liner cargo vessels, the ranking of operators...

  3. Spectra of copperlike and zinclike xenon: Xe XXV and Xe XXVI

    International Nuclear Information System (INIS)

    Kaufman, V.; Sugar, J.; Rowan, W.L.

    1988-01-01

    The spectra of highly ionized xenon were generated in a tokamak plasma and photographed in the region 60--350 A with a 2.2-m grazing-incidence spectrograph. The 4s 2 --4s4p transitions of Zn-like xenon (Xe XXV) and all the 4l--4(l+1) transitions of Cu-like xenon (Xe XXVI) were measured with estimated uncertainties of +- 0.005 A. These measurements have been combined with previous wavelength measurements of Xe XXVI to determine energy levels. A value for the ionization energy of Xe 25+ of 6 912 400 +- 3000 cm -1 (857.0 +- 0.4 eV) was derived

  4. [Experimental evaluation of the Sysmex UF-1000i for ruling out non-gonococcal urethritis].

    Science.gov (United States)

    Grosso, Shamanta; Bruschetta, Graziano; Camporese, Alessandro

    2012-09-01

    Acute nongonococcal urethritis (NGU) is one of the commonest sexually transmitted infections affecting men and women. The diagnosis of NGU has traditionally required microscopic evidence of urethritis. However, a significant proportion of patients with urethral symptoms do not have microscopic evidence of urethritis. The purpose of the present study was to evaluate the analytical performance of the UF1000i, a recently introduced fluorescence flow cytometer intended for urinalysis purposes which provides new analytical features that seem particularly suitable for microbiological diagnostics, for ruling out NGU or predicting the presence of infection. The Sysmex UF1000i is a flow cytometry analyzer capable of quantifying a lot of particles, including bacteria (BACT) and white blood cells (WBCs). To evaluate the analytical performance of the UF1000i as a method for ruling out NGU, we examined 200 urethral smear samples, collected in a new liquid transport medium (Copan), and compared the UF1000i results with standard culture/molecular and microscopic Gram stain results. With instrument cut-off values of 200 BACT x 10^6/L and 500 WBCs x 10^6/L, we obtained a sensitivity of 84%, a specificity of 82%, and a high negative predictive value (96%). Culture/molecular detection of pathogens remains the gold standard technique for the diagnosis of NGU. However, the Sysmex UF1000i is capable of improving the efficiency of NGU presumptive diagnosis, providing results in a few minutes, with a high negative predictive value and high values of sensitivity.

  5. Energy levels and radiative rates for transitions in B-like to F-like Xe ions (Xe L-XLVI)

    International Nuclear Information System (INIS)

    Aggarwal, K.M.; Keenan, F.P.; Lawson, K.D.

    2010-01-01

    Energy levels, radiative rates, oscillator strengths, line strengths, and lifetimes have been calculated for transitions in B-like to F-like Xe ions, Xe L-XLVI. For the calculations, a fully relativistic GRASP code has been adopted, and results are reported for all electric dipole, electric quadrupole, magnetic dipole, and magnetic quadrupole transitions among the lowest 125, 236, 272, 226, and 113 levels of Xe L, Xe XLIX, Xe XLVIII, Xe XLVII, and Xe XLVI, respectively, belonging to the n ≤ 3 configurations.

  6. The International Atomic Energy Agency Flag Code

    International Nuclear Information System (INIS)

    1999-01-01

    The document reproduces the text of the IAEA Flag Code which was promulgated by the Director General on 15 September 1999, pursuant to the decision of the Board of Governors on 10 June 1999 to adopt an Agency flag as described in document GOV/1999/41 and its use in accordance with a flag code to be promulgated by the Director General

  7. The International Atomic Energy Agency Flag Code

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-11-17

    The document reproduces the text of the IAEA Flag Code which was promulgated by the Director General on 15 September 1999, pursuant to the decision of the Board of Governors on 10 June 1999 to adopt an Agency flag as described in document GOV/1999/41 and its use in accordance with a flag code to be promulgated by the Director General.

  8. ISO/IEC 17025 Sysmex R-500 hematology reticulocyte analyzer validation.

    Science.gov (United States)

    Dimopoulou, H A; Theodoridis, T; Galea, V; Christopoulou-Cokkinou, V; Spyridaki, M-H E; Georgakopoulos, C G

    2007-01-01

    The Sysmex R-500 (R-500) Hematology Analyzer is a bench-top system appropriate for the analysis of limited batches of blood samples. The R-500 provides percentage proportional (RET%), absolute reticulocyte (RET#), and absolute red blood cell (RBC#) counts. The system was validated at the Doping Control Laboratory of Athens, according to the International Committee for Standardization in Hematology, International Standards Organization (ISO/IEC) 17025, and World Antidoping Agency (WADA) specifications. The instrument calibration was performed according to the manufacturer and validation parameters comprised linearity, precision, uncertainty (intermediate and long-term precision), comparability, effect of drift, carryover, stability, and accuracy. The linearity and the comparability studies for RET#, RET%, and RBC# were expressed in regression factors (R2) and coefficients of correlation [r(x, y)], respectively. For the precision studies, the coefficients of variation for RET#, RET%, and RBC# were 9.49%, 9.83%, and ISO/IEC 17025 and WADA specifications.

  9. RFI flagging implications for short-duration transients

    Science.gov (United States)

    Cendes, Y.; Prasad, P.; Rowlinson, A.; Wijers, R. A. M. J.; Swinbank, J. D.; Law, C. J.; van der Horst, A. J.; Carbone, D.; Broderick, J. W.; Staley, T. D.; Stewart, A. J.; Huizinga, F.; Molenaar, G.; Alexov, A.; Bell, M. E.; Coenen, T.; Corbel, S.; Eislöffel, J.; Fender, R.; Grießmeier, J.-M.; Jonker, P.; Kramer, M.; Kuniyoshi, M.; Pietka, M.; Stappers, B.; Wise, M.; Zarka, P.

    2018-04-01

    With their wide fields of view and often relatively long coverage of any position in the sky in imaging survey mode, modern radio telescopes provide a data stream that is naturally suited to searching for rare transients. However, Radio Frequency Interference (RFI) can show up in the data stream in similar ways to such transients, and thus the normal pre-treatment of filtering RFI (flagging) may also remove astrophysical transients from the data stream before imaging. In this paper we investigate how standard flagging affects the detectability of such transients by examining the case of transient detection in an observing mode used for Low Frequency Array (LOFAR; van Haarlem et al., 2013) surveys. We quantify the fluence range of transients that would be detected, and the reduction of their SNR due to partial flagging. We find that transients with a duration close to the integration sampling time, as well as bright transients with durations on the order of tens of seconds, are completely flagged. For longer transients on the order of several tens of seconds to minutes, the flagging effects are not as severe, although part of the signal is lost. For these transients, we present a modified flagging strategy which mitigates the effect of flagging on transient signals. We also present a script which uses the differences between the two strategies, and known differences between transient RFI and astrophysical transients, to notify the observer when a potential transient is in the data stream.

  10. XeBr exciplex laser

    International Nuclear Information System (INIS)

    Searles, S.K.

    1976-01-01

    Laser emission from the recently discovered XeBr exciplex laser was investigated as a function of the partial pressures of Xe and Br 2 . An optical loss process appears to limit high-pressure operation

  11. Rb-129Xe spin-exchange rates due to binary and three-body collisions at high Xe pressures

    International Nuclear Information System (INIS)

    Cates, G.D.; Fitzgerald, R.J.; Barton, A.S.; Bogorad, P.; Gatzke, M.; Newbury, N.R.; Saam, B.

    1992-01-01

    We have studied the spin relaxation of 129 Xe nuclei due to collisions with Rb atoms at Xe pressures of 245--1817 Torr. Our results can be characterized by two parameters, the Rb- 129 Xe velocity-averaged binary spin-exchange cross section left-angle σv right-angle and a rate γ M that characterizes spin relaxation due to van der Waals molecules. Our results complement earlier studies performed at Xe pressures of about 1 Torr and N 2 pressures of 10--100 Torr. This work is useful for predicting spin-exchange rates between polarized Rb atoms and 129 Xe nuclei

  12. 5 CFR 2100.12 - Accounting of disclosure.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Accounting of disclosure. 2100.12 Section... PROCEDURES § 2100.12 Accounting of disclosure. (a) The AFRH or agency will maintain a record of disclosures... in the performance of their duties. (b) This accounting of the disclosures will be retained for a...

  13. 49 CFR 218.37 - Flag protection.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Flag protection. 218.37 Section 218.37..., DEPARTMENT OF TRANSPORTATION RAILROAD OPERATING PRACTICES Protection of Trains and Locomotives § 218.37 Flag protection. (a) After August 1, 1977, each railroad must have in effect an operating rule which complies with...

  14. Complete blood count reference values of cord blood in Taiwan and the influence of gender and delivery route on them.

    Science.gov (United States)

    Chang, Yu-Hsun; Yang, Shang-Hsien; Wang, Tso-Fu; Lin, Teng-Yi; Yang, Kuo-Liang; Chen, Shu-Huey

    2011-06-01

    Cord blood banking has become more popular in recent years. Checking cord blood complete blood count (CBC) and white blood cell (WBC) differential counts (DCs) is essential before cryopreserving the cord blood units. Therefore, establishing the normal reference values of cord blood CBC and WBC DC is important in clinical practice and research. To obtain a large-scale population-based normal CBC and WBC DC reference values of healthy neonates' cord blood from a public cord blood bank and to investigate the influence of the gender and delivery route. From September 2001 to November 2006, the cord blood of healthy Taiwanese neonates with gestational age 36 weeks and more were collected by Tzu Chi Cord Blood Bank with written informed consents. All cord blood samples were analyzed by Sysmex XE2100 automated hematology analyzer (Sysmex Corporation, Kobe, Japan) to obtain the CBC. The WBC DC was calculated by manual method. We used Student's t test and Mann-Whitney U test for investigating the influences of gender and delivery route on the CBC and WBC DC reference values. The results were presented by mean±standard deviation or 2.5-97.5th percentiles. In the study period, totally 5602 cord blood samples were collected eligibly for analysis. The cord blood CBC and WBC DC normal reference values were calculated. The female neonates had significantly higher mean corpuscular volume, platelet count, and WBC count, but lower red blood cell (RBC) count, hemoglobin (Hb), hematocrit, and mean corpuscular Hb concentration values (pTaiwan. Gender and delivery routes were important confounding factors that influenced the cord blood CBC and WBC DC values. Copyright © 2011. Published by Elsevier B.V.

  15. Evaluation of the i-STAT point-of-care analyzer in critically ill adult patients.

    Science.gov (United States)

    Steinfelder-Visscher, Jacoline; Teerenstra, Steven; Gunnewiek, Jacqueline M T Klein; Weerwind, Patrick W

    2008-03-01

    Point-of-care analyzers may benefit therapeutic decision making by reducing turn-around-time for samples. This is especially true when biochemical parameters exceed the clinical reference range, in which acute and effective treatment is essential. We therefore evaluated the analytical performance of the i-STAT point-of-care analyzer in two critically ill adult patient populations. During a 3-month period, 48 blood samples from patients undergoing cardiac surgery with cardiopulmonary bypass (CPB) and 42 blood samples from non-cardiac patients who needed intensive care treatment were analyzed on both the i-STAT analyzer (CPB and non-CPB mode, respectively) and our laboratory analyzers (RapidLab 865/Sysmex XE-2100 instrument). The agreement analysis for quantitative data was used to compare i-STAT to RapidLab for blood gas/electrolytes and for hematocrit with the Sysmex instrument. Point-of-care electrolytes and blood gases had constant deviation, except for pH, pO2, and hematocrit. A clear linear trend in deviation of i-STAT from RapidLab was noticed for pH during CPB (r = 0.32, p = .03) and for pO2 > 10 kPa during CPB (r = -0.59, p pO2 pO2 pO2 range (10.6 pO2 range below 25% (n = 11) using the i-STAT. The i-STAT analyzer is suitable for point-of-care testing of electrolytes and blood gases in critically ill patients, except for high pO2. However, the discrepancy in hematocrit bias shows that accuracy established in one patient population cannot be automatically extrapolated to other patient populations, thus stressing the need for separate evaluation.

  16. XENON IN THE PROTOPLANETARY DISK (PPD-Xe)

    Energy Technology Data Exchange (ETDEWEB)

    Marti, K.; Mathew, K. J., E-mail: kattathu.mathew@srs.gov [Department of Chemistry and Biochemistry, University of California, San Diego, La Jolla, CA (United States)

    2015-06-20

    Relationships among solar system Xe components as observed in the solar wind, in planetary atmospheres, and in meteorites are investigated using isotopic correlations. The term PPD-Xe is used for components inferred to have been present in the molecular cloud material that formed the protoplanetary disk (PPD). The evidence of the lack of simple relationships between terrestrial atmospheric Xe and solar or meteoritic components is confirmed. Xe isotopic correlations indicate a heterogeneous PPD composition with variable mixing ratios of the nucleosynthetic component Xe-HL. Solar Xe represents a bulk PPD component, and the isotopic abundances did not change from the time of incorporation into the interior of Mars through times of regolith implantations to the present.

  17. XENON IN THE PROTOPLANETARY DISK (PPD-Xe)

    International Nuclear Information System (INIS)

    Marti, K.; Mathew, K. J.

    2015-01-01

    Relationships among solar system Xe components as observed in the solar wind, in planetary atmospheres, and in meteorites are investigated using isotopic correlations. The term PPD-Xe is used for components inferred to have been present in the molecular cloud material that formed the protoplanetary disk (PPD). The evidence of the lack of simple relationships between terrestrial atmospheric Xe and solar or meteoritic components is confirmed. Xe isotopic correlations indicate a heterogeneous PPD composition with variable mixing ratios of the nucleosynthetic component Xe-HL. Solar Xe represents a bulk PPD component, and the isotopic abundances did not change from the time of incorporation into the interior of Mars through times of regolith implantations to the present

  18. Xenon in the Protoplanetary Disk (PPD-Xe)

    Science.gov (United States)

    Marti, K.; Mathew, K. J.

    2015-06-01

    Relationships among solar system Xe components as observed in the solar wind, in planetary atmospheres, and in meteorites are investigated using isotopic correlations. The term PPD-Xe is used for components inferred to have been present in the molecular cloud material that formed the protoplanetary disk (PPD). The evidence of the lack of simple relationships between terrestrial atmospheric Xe and solar or meteoritic components is confirmed. Xe isotopic correlations indicate a heterogeneous PPD composition with variable mixing ratios of the nucleosynthetic component Xe-HL. Solar Xe represents a bulk PPD component, and the isotopic abundances did not change from the time of incorporation into the interior of Mars through times of regolith implantations to the present.

  19. 133Xe and 135Xe interference with in vivo low-energy measurement systems

    International Nuclear Information System (INIS)

    Cohen, N.; Lo Sasso, T.; Lei, W.

    1980-01-01

    Fission product 133 Xe and 135 Xe are released to the atmosphere during normal reactor operation. With increasing numbers of nuclear power stations there will be an increase in the ambient level of these isotopes. They do not present an appreciable long-term health hazard because of their inert nature and relatively short half-lives. However, their presence in the air of a whole-body counter may interfere significantly with in vivo low-energy photon counting procedures by contributing to the background count-rate in the energy region below 300 keV. This applies particularly to lung and whole-body measurements with dual thin crystal NaI(Tl)-CsI(Tl) scintillation detectors for actinide nuclides. It is important, therefore, that gamma spectroscopists should be aware of the possible presence of 133 Xe and 135 Xe in the air of their whole-body counting facilities, particularly if these are near to reactors and do not have traps for removal of inert gases from their air supplies. (author)

  20. Study on decay of 118Xe and 119Xe by means of mass-separator on-line with a synchrocyclotron

    International Nuclear Information System (INIS)

    Berlovich, Eh.E.; Batist, L.Kh.; Blinnikov, Yu.S.

    1976-01-01

    The decay of sup(118, 119)Xe isotopes has been investigated. An experimental device involving a mass-separator operating in line with a synchrocyclotron is briefly outlined. The elements to be investigated were isolated from a proton-irradiated target by the 'on-beam-chemistry' methods and transferred into the mass-separator ion source. The Xe separated ions are transported to detectors in an experimental ha ll. The energies and relative γ ray intensities of 118 Xe → 118 J and of 119 Xe → 119 J decays ar presented. The error of the γ ray energy determination does not exceed 0.6 keV. Obtained are the periods of half-life: for 118 Xe - (3.8+-0.9) min, for 119 Xe - (5.8+-0.3) min. The decay scheme for 119 Xe is made up. The scheme of 119 Xe levels is well inscribed into the general systematics of the J odd isotope levels. On the basis of obtained and known data the spin values are described to the 119 J levels

  1. High energy XeBr electric discharge laser

    Science.gov (United States)

    Sze, Robert C.; Scott, Peter B.

    1981-01-01

    A high energy XeBr laser for producing coherent radiation at 282 nm. The XeBr laser utilizes an electric discharge as the excitation source to minimize formation of molecular ions thereby minimizing absorption of laser radiation by the active medium. Additionally, HBr is used as the halogen donor which undergoes harpooning reactions with Xe.sub.M * to form XeBr*.

  2. Hepatitis C virus expressing flag-tagged envelope protein 2 has unaltered infectivity and density, is specifically neutralized by flag antibodies and can be purified by affinity chromatography

    DEFF Research Database (Denmark)

    Prentø, Jannick Cornelius; Bukh, Jens

    2011-01-01

    to the original virus. Flag-tagged virus was susceptible to flag-specific antibody neutralization, and infected cells could be immuno-stained by anti-flag antibodies. Using affinity chromatography with anti-flag resin we repeatedly obtained ~30% recovery of infectious particles. The full viability and unaltered...

  3. Analysis of 125Xe electron-photon coincidence decay

    International Nuclear Information System (INIS)

    Klingberg, F.J.; Biegalski, S.R.

    2016-01-01

    As part of the verification component of the Comprehensive Nuclear-Test-Ban Treaty (CTBT), environmental gas samples originating from nuclear fission are analyzed for the presence of 131m Xe, 133m Xe, 133 Xe, and 135 Xe. In this work, the non-traditional radioxenon isotope 125 Xe was investigated. The isotope was produced as an isotopically pure sample via neutron activation of 124 Xe at the University of Texas at Austin Nuclear Engineering Teaching Lab's TRIGA MARK II Reactor. The sample was then measured using a HPGe detector as well as an ARSA-style b-c coincidence detector. Potential sources and sensitivities for production of 125 Xe are also considered for relevance to the CTBT verification mission. (author)

  4. Charge transfer reactions in Xe plasma expansion

    International Nuclear Information System (INIS)

    Jiao, C. Q.; Garscadden, A.; Ganguly, B. N.

    2007-01-01

    Charge transfer reactions of fast Xe ions with hydrocarbons including methane (CH 4 ), ethene (C 2 H 4 ), and propane (C 3 H 8 ) are studied by adding these hydrocarbon gases into a cross flowing Xe plasma expansion. Branching ratios and relative reaction rates for the charge transfers of fast Xe + with each of the three hydrocarbon gases are measured under different rf powers of the inductively coupled Xe discharge. For CH 4 /Xe system, we find that fast Xe + reacts readily with CH 4 generating CH 4 + and CH 3 + in a ratio of 1:0.56, with an estimated rate coefficient of (2.3±0.3)x10 -10 cm 3 /s at 75 W rf power which slowly increases to (2.9±0.3)x10 -10 cm 3 /s at 250 W (error bars reflect only the uncertainties due to the unknown extent of the ion recombination that follows the charge transfer reaction). These observed charge transfer reactions are made possible by the kinetically excited Xe ions produced by free expansion of the plasma. For the C 2 H 4 /Xe system product ions C 2 H 4 + and C 2 H 2 + are observed, and for C 3 H 8 /Xe, C 2 H 4 + and C 2 H 5 + and minor product ions including C 2 H 2 + and C 3 H 7 + are observed

  5. Biological Studies with Laser-Polarized ^129Xe

    Science.gov (United States)

    Tseng, C. H.; Oteiza, E. R.; Wong, G. A.; Walsworth, R. L.; Albert, M. S.; Nascimben, L.; Peled, S.; Sakai, K.; Jolesz, F. A.

    1996-05-01

    We have studied several biological systems using laser-polarized ^129Xe. In certain tissues magnetic resonance imaging (MRI) using inhaled laser-polarized noble gases may provide images superior to those from conventional proton MRI. High resolution laser-polarized ^3He images of air spaces in the human lung were recently obtained by the Princeton/Duke group. However, ^3He is not very soluble in tissue. Therefore, we are using laser polarized ^129Xe (tissue-soluble), with the long term goal of biomedical functional imaging. We have investigated multi-echo and multi-excitation magnetic resonance detection schemes to exploit the highly non-thermal ^129Xe magnetization produced by the laser polarization technique. We have inhalated live rats with laser-polarized ^129Xe gas and measured three distinct ^129Xe tissue resonances that last 20 to 40 sec. As a demonstration, we obtained a laser polarized ^129Xe image of the human oral cavity. Currently we are measuring the polarization lifetime of ^129Xe dissolved in human blood, the biological transporting medium. These studies and other recent developments will be reported.

  6. Emission characteristics of Xe-RbBr plasma

    Science.gov (United States)

    Heneral, A. A.; Avtaeva, S. V.

    2017-12-01

    The luminescence spectra of the longitudinal pulsed-periodic discharge in Xe-RbBr gas-vapour mixtures at low pressures are experimentally studied. Conditions for obtaining strong UV radiation of XeBr* exiplex molecules in the spectral range of 200-425 nm are found. The greatest output of the XeBr* UV radiation is provided at temperature of the gas-discharge tube walls of ~1000 K. The maximum UV emission power of the whole plasma volume is 4.8 W. Formation of XeBr* exciplex molecules in the pulsed-periodic discharge in Xe-RbBr gas-vapour mixtures at low pressures is discussed.

  7. Syntheses, Raman spectra, and X-ray crystal structures of [XeF(5)][mu-F(OsO(3)F(2))(2)] and [M][OsO(3)F(3)] (M = XeF(5)(+), Xe(2)F(11)(+)).

    Science.gov (United States)

    Hughes, Michael J; Mercier, Hélène P A; Schrobilgen, Gary J

    2010-04-05

    Stoichiometric amounts of XeF(6) and (OsO(3)F(2))(infinity) react at 25-50 degrees C to form salts of the known XeF(5)(+) and Xe(2)F(11)(+) cations, namely, [XeF(5)][mu-F(OsO(3)F(2))(2)], [XeF(5)][OsO(3)F(3)], and [Xe(2)F(11)][OsO(3)F(3)]. Although XeF(6) is oxophilic toward a number of transition metal and main-group oxides and oxide fluorides, fluoride/oxide metathesis was not observed. The series provides the first examples of noble-gas cations that are stabilized by metal oxide fluoride anions and the first example of a mu-F(OsO(3)F(2))(2)(-) salt. Both [XeF(5)][mu-F(OsO(3)F(2))(2)] and [Xe(2)F(11)][OsO(3)F(3)] are orange solids at room temperature. The [XeF(5)][OsO(3)F(3)] salt is an orange liquid at room temperature that solidifies at 5-0 degrees C. When the salts are heated at 50 degrees C under 1 atm of N(2) for more than 2 h, significant XeF(6) loss occurs. The X-ray crystal structures (-173 degrees C) show that the salts exist as discrete ion pairs and that the osmium coordination spheres in OsO(3)F(3)(-) and mu-F(OsO(3)F(2))(2)(-) are pseudo-octahedral OsO(3)F(3)-units having facial arrangements of oxygen and fluorine atoms. The mu-F(OsO(3)F(2))(2)(-) anion is comprised of two symmetry-related OsO(3)F(2)-groups that are fluorine-bridged to one another. Ion pairing results from secondary bonding interactions between the fluorine/oxygen atoms of the anions and the xenon atom of the cation, with the Xe...F/O contacts occurring opposite the axial fluorine and from beneath the equatorial XeF(4)-planes of the XeF(5)(+) and Xe(2)F(11)(+) cations so as to avoid the free valence electron lone pairs of the xenon atoms. The xenon atoms of [XeF(5)][mu-F(OsO(3)F(2))(2)] and [Xe(2)F(11)][OsO(3)F(3)] are nine-coordinate and the xenon atom of [XeF(5)][OsO(3)F(3)] is eight-coordinate. Quantum-chemical calculations at SVWN and B3LYP levels of theory were used to obtain the gas-phase geometries, vibrational frequencies, and NBO bond orders, valencies, and NPA charges of

  8. 76 FR 35087 - Flag Day and National Flag Week, 2011

    Science.gov (United States)

    2011-06-15

    ... flag with thirteen stripes and thirteen stars to represent our Nation, one star for each of our founding colonies. The stars were set upon a blue field, in the words of the Congress's resolution, ``representing a new constellation'' in the night sky. What was then a fledgling democracy has flourished and...

  9. 21 CFR 522.2100 - Selenium, vitamin E injection.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Selenium, vitamin E injection. 522.2100 Section... § 522.2100 Selenium, vitamin E injection. (a)(1) Specifications. The drug is an emulsion containing in... of vitamin E (68 I.U.) (as d-alpha tocopheryl acetate). (2) Sponsor. See No. 000061 in § 510.600(c...

  10. Charged particle suppression in Pb+Pb and Xe+Xe collisions measured with the ATLAS detector

    CERN Document Server

    Balek, Petr; The ATLAS collaboration

    2018-01-01

    The measurement of charge particle production in heavy ion collisions, when compared with pp data, provides insight into the properties of the hot and dense quark-gluon plasma. The ATLAS detector at the LHC recorded 0.49 nb$^{−1}$ of Pb+Pb collisions and 4.2 pb$^{−1}$ of pp collisions, both at the center-of-mass energy $\\sqrt{s}=\\sqrt{s_{NN}}=5.02$ TeV. Recently, ATLAS also recorded 3 $\\mu$b$^{−1}$ of Xe+Xe collisions at $\\sqrt{s_{NN}}=5.44$ TeV, which offers a new opportunity to study the system size dependence of the parton energy loss. The large acceptance of the ATLAS detector allows measurements of charged hadron spectra in a wide range of both pseudorapidity and transverse momentum, differentially in collision centrality. The charged hadron spectra measured in Pb+Pb and Xe+Xe collisions are compared to the analogous spectra measured in pp collisions, and the resulting nuclear modification factors $R_{AA}$ are studied.

  11. QTL mapping of flag leaf-related traits in wheat (Triticum aestivum L.).

    Science.gov (United States)

    Liu, Kaiye; Xu, Hao; Liu, Gang; Guan, Panfeng; Zhou, Xueyao; Peng, Huiru; Yao, Yingyin; Ni, Zhongfu; Sun, Qixin; Du, Jinkun

    2018-04-01

    QTL controlling flag leaf length, flag leaf width, flag leaf area and flag leaf angle were mapped in wheat. This study aimed to advance our understanding of the genetic mechanisms underlying morphological traits of the flag leaves of wheat (Triticum aestivum L.). A recombinant inbred line (RIL) population derived from ND3331 and the Tibetan semi-wild wheat Zang1817 was used to identify quantitative trait loci (QTLs) controlling flag leaf length (FLL), flag leaf width (FLW), flag leaf area (FLA), and flag leaf angle (FLANG). Using an available simple sequence repeat genetic linkage map, 23 putative QTLs for FLL, FLW, FLA, and FLANG were detected on chromosomes 1B, 2B, 3A, 3D, 4B, 5A, 6B, 7B, and 7D. Individual QTL explained 4.3-68.52% of the phenotypic variance in different environments. Four QTLs for FLL, two for FLW, four for FLA, and five for FLANG were detected in at least two environments. Positive alleles of 17 QTLs for flag leaf-related traits originated from ND3331 and 6 originated from Zang1817. QTLs with pleiotropic effects or multiple linked QTL were also identified on chromosomes 1B, 4B, and 5A; these are potential target regions for fine-mapping and marker-assisted selection in wheat breeding programs.

  12. Inclusive J/$\\psi$ production in Xe-Xe collisions at $\\sqrt{s_{NN}}$ = 5.44 TeV

    CERN Document Server

    Acharya, Shreyasi; The ALICE collaboration; Adamova, Dagmar; Adolfsson, Jonatan; Aggarwal, Madan Mohan; Aglieri Rinella, Gianluca; Agnello, Michelangelo; Agrawal, Neelima; Ahammed, Zubayer; Ahn, Sang Un; Aiola, Salvatore; Akindinov, Alexander; Al-turany, Mohammad; Alam, Sk Noor; Silva De Albuquerque, Danilo; Aleksandrov, Dmitry; Alessandro, Bruno; Alfaro Molina, Jose Ruben; Ali, Yasir; Alici, Andrea; Alkin, Anton; Alme, Johan; Alt, Torsten; Altenkamper, Lucas; Altsybeev, Igor; Anaam, Mustafa Naji; Andrei, Cristian; Andreou, Dimitra; Andrews, Harry Arthur; Andronic, Anton; Angeletti, Massimo; Anguelov, Venelin; Anson, Christopher Daniel; Anticic, Tome; Antinori, Federico; Antonioli, Pietro; Anwar, Rafay; Apadula, Nicole; Aphecetche, Laurent Bernard; Appelshaeuser, Harald; Arcelli, Silvia; Arnaldi, Roberta; Arnold, Oliver Werner; Arsene, Ionut Cristian; Arslandok, Mesut; Audurier, Benjamin; Augustinus, Andre; Averbeck, Ralf Peter; Azmi, Mohd Danish; Badala, Angela; Baek, Yong Wook; Bagnasco, Stefano; Bailhache, Raphaelle Marie; Bala, Renu; Baldisseri, Alberto; Ball, Markus; Baral, Rama Chandra; Barbano, Anastasia Maria; Barbera, Roberto; Barile, Francesco; Barioglio, Luca; Barnafoldi, Gergely Gabor; Barnby, Lee Stuart; Ramillien Barret, Valerie; Bartalini, Paolo; Barth, Klaus; Bartsch, Esther; Bastid, Nicole; Basu, Sumit; Batigne, Guillaume; Batyunya, Boris; Batzing, Paul Christoph; Bazo Alba, Jose Luis; Bearden, Ian Gardner; Beck, Hans; Bedda, Cristina; Behera, Nirbhay Kumar; Belikov, Iouri; Bellini, Francesca; Bello Martinez, Hector; Bellwied, Rene; Espinoza Beltran, Lucina Gabriela; Belyaev, Vladimir; Bencedi, Gyula; Beole, Stefania; Bercuci, Alexandru; Berdnikov, Yaroslav; Berenyi, Daniel; Bertens, Redmer Alexander; Berzano, Dario; Betev, Latchezar; Bhaduri, Partha Pratim; Bhasin, Anju; Bhat, Inayat Rasool; Bhatt, Himani; Bhattacharjee, Buddhadeb; Bhom, Jihyun; Bianchi, Antonio; Bianchi, Livio; Bianchi, Nicola; Bielcik, Jaroslav; Bielcikova, Jana; Bilandzic, Ante; Biro, Gabor; Biswas, Rathijit; Biswas, Saikat; Blair, Justin Thomas; Blau, Dmitry; Blume, Christoph; Boca, Gianluigi; Bock, Friederike; Bogdanov, Alexey; Boldizsar, Laszlo; Bombara, Marek; Bonomi, Germano; Bonora, Matthias; Borel, Herve; Borissov, Alexander; Borri, Marcello; Botta, Elena; Bourjau, Christian; Bratrud, Lars; Braun-munzinger, Peter; Bregant, Marco; Broker, Theo Alexander; Broz, Michal; Brucken, Erik Jens; Bruna, Elena; Bruno, Giuseppe Eugenio; Budnikov, Dmitry; Buesching, Henner; Bufalino, Stefania; Buhler, Paul; Buncic, Predrag; Busch, Oliver; Buthelezi, Edith Zinhle; Bashir Butt, Jamila; Buxton, Jesse Thomas; Cabala, Jan; Caffarri, Davide; Caines, Helen Louise; Caliva, Alberto; Calvo Villar, Ernesto; Soto Camacho, Rabi; Camerini, Paolo; Capon, Aaron Allan; Carena, Francesco; Carena, Wisla; Carnesecchi, Francesca; Castillo Castellanos, Javier Ernesto; Castro, Andrew John; Casula, Ester Anna Rita; Ceballos Sanchez, Cesar; Chandra, Sinjini; Chang, Beomsu; Chang, Wan; Chapeland, Sylvain; Chartier, Marielle; Chattopadhyay, Subhasis; Chattopadhyay, Sukalyan; Chauvin, Alex; Cheshkov, Cvetan Valeriev; Cheynis, Brigitte; Chibante Barroso, Vasco Miguel; Dobrigkeit Chinellato, David; Cho, Soyeon; Chochula, Peter; Chowdhury, Tasnuva; Christakoglou, Panagiotis; Christensen, Christian Holm; Christiansen, Peter; Chujo, Tatsuya; Chung, Suh-urk; Cicalo, Corrado; Cifarelli, Luisa; Cindolo, Federico; Cleymans, Jean Willy Andre; Colamaria, Fabio Filippo; Colella, Domenico; Collu, Alberto; Colocci, Manuel; Concas, Matteo; Conesa Balbastre, Gustavo; Conesa Del Valle, Zaida; Contreras Nuno, Jesus Guillermo; Cormier, Thomas Michael; Corrales Morales, Yasser; Cortese, Pietro; Cosentino, Mauro Rogerio; Costa, Filippo; Costanza, Susanna; Crkovska, Jana; Crochet, Philippe; Cuautle Flores, Eleazar; Cunqueiro Mendez, Leticia; Dahms, Torsten; Dainese, Andrea; Dani, Sanskruti; Danisch, Meike Charlotte; Danu, Andrea; Das, Debasish; Das, Indranil; Das, Supriya; Dash, Ajay Kumar; Dash, Sadhana; De, Sudipan; De Caro, Annalisa; De Cataldo, Giacinto; De Conti, Camila; De Cuveland, Jan; De Falco, Alessandro; De Gruttola, Daniele; De Marco, Nora; De Pasquale, Salvatore; Derradi De Souza, Rafael; Franz Degenhardt, Hermann; Deisting, Alexander; Deloff, Andrzej; Delsanto, Silvia; Deplano, Caterina; Dhankher, Preeti; Di Bari, Domenico; Di Mauro, Antonio; Di Ruzza, Benedetto; Arteche Diaz, Raul; Dietel, Thomas; Dillenseger, Pascal; Ding, Yanchun; Divia, Roberto; Djuvsland, Oeystein; Dobrin, Alexandru Florin; Domenicis Gimenez, Diogenes; Donigus, Benjamin; Dordic, Olja; Van Doremalen, Lennart Vincent; Dubey, Anand Kumar; Dubla, Andrea; Ducroux, Laurent; Dudi, Sandeep; Duggal, Ashpreet Kaur; Dukhishyam, Mallick; Dupieux, Pascal; Ehlers Iii, Raymond James; Elia, Domenico; Endress, Eric; Engel, Heiko; Epple, Eliane; Erazmus, Barbara Ewa; Erhardt, Filip; Ersdal, Magnus Rentsch; Espagnon, Bruno; Eulisse, Giulio; Eum, Jongsik; Evans, David; Evdokimov, Sergey; Fabbietti, Laura; Faggin, Mattia; Faivre, Julien; Fantoni, Alessandra; Fasel, Markus; Feldkamp, Linus; Feliciello, Alessandro; Feofilov, Grigorii; Fernandez Tellez, Arturo; Ferretti, Alessandro; Festanti, Andrea; Feuillard, Victor Jose Gaston; Figiel, Jan; Araujo Silva Figueredo, Marcel; Filchagin, Sergey; Finogeev, Dmitry; Fionda, Fiorella; Fiorenza, Gabriele; Flor, Fernando; Floris, Michele; Foertsch, Siegfried Valentin; Foka, Panagiota; Fokin, Sergey; Fragiacomo, Enrico; Francescon, Andrea; Francisco, Audrey; Frankenfeld, Ulrich Michael; Fronze, Gabriele Gaetano; Fuchs, Ulrich; Furget, Christophe; Furs, Artur; Fusco Girard, Mario; Gaardhoeje, Jens Joergen; Gagliardi, Martino; Gago Medina, Alberto Martin; Gajdosova, Katarina; Gallio, Mauro; Duarte Galvan, Carlos; Ganoti, Paraskevi; Garabatos Cuadrado, Jose; Garcia-solis, Edmundo Javier; Garg, Kunal; Gargiulo, Corrado; Gasik, Piotr Jan; Gauger, Erin Frances; De Leone Gay, Maria Beatriz; Germain, Marie; Ghosh, Jhuma; Ghosh, Premomoy; Ghosh, Sanjay Kumar; Gianotti, Paola; Giubellino, Paolo; Giubilato, Piero; Glassel, Peter; Gomez Coral, Diego Mauricio; Gomez Ramirez, Andres; Gonzalez, Victor; Gonzalez Zamora, Pedro; Gorbunov, Sergey; Gorlich, Lidia Maria; Gotovac, Sven; Grabski, Varlen; Graczykowski, Lukasz Kamil; Graham, Katie Leanne; Greiner, Leo Clifford; Grelli, Alessandro; Grigoras, Costin; Grigoryev, Vladislav; Grigoryan, Ara; Grigoryan, Smbat; Gronefeld, Julius Maximilian; Grosa, Fabrizio; Grosse-oetringhaus, Jan Fiete; Grosso, Raffaele; Guernane, Rachid; Guerzoni, Barbara; Guittiere, Manuel; Gulbrandsen, Kristjan Herlache; Gunji, Taku; Gupta, Anik; Gupta, Ramni; Bautista Guzman, Irais; Haake, Rudiger; Habib, Michael Karim; Hadjidakis, Cynthia Marie; Hamagaki, Hideki; Hamar, Gergoe; Hamid, Mohammed; Hamon, Julien Charles; Hannigan, Ryan; Haque, Md Rihan; Harris, John William; Harton, Austin Vincent; Hassan, Hadi; Hatzifotiadou, Despina; Hayashi, Shinichi; Heckel, Stefan Thomas; Hellbar, Ernst; Helstrup, Haavard; Herghelegiu, Andrei Ionut; Gonzalez Hernandez, Emma; Herrera Corral, Gerardo Antonio; Herrmann, Florian; Hetland, Kristin Fanebust; Hilden, Timo Eero; Hillemanns, Hartmut; Hills, Christopher; Hippolyte, Boris; Hohlweger, Bernhard; Horak, David; Hornung, Sebastian; Hosokawa, Ritsuya; Hota, Jyotishree; Hristov, Peter Zahariev; Huang, Chun-lu; Hughes, Charles; Huhn, Patrick; Humanic, Thomas; Hushnud, Hushnud; Hussain, Nur; Hussain, Tahir; Hutter, Dirk; Hwang, Dae Sung; Iddon, James Philip; Iga Buitron, Sergio Arturo; Ilkaev, Radiy; Inaba, Motoi; Ippolitov, Mikhail; Islam, Md Samsul; Ivanov, Marian; Ivanov, Vladimir; Izucheev, Vladimir; Jacak, Barbara; Jacazio, Nicolo; Jacobs, Peter Martin; Jadhav, Manoj Bhanudas; Jadlovska, Slavka; Jadlovsky, Jan; Jaelani, Syaefudin; Jahnke, Cristiane; Jakubowska, Monika Joanna; Janik, Malgorzata Anna; Jena, Chitrasen; Jercic, Marko; Jevons, Oliver; Jimenez Bustamante, Raul Tonatiuh; Jin, Muqing; Jones, Peter Graham; Jusko, Anton; Kalinak, Peter; Kalweit, Alexander Philipp; Kang, Ju Hwan; Kaplin, Vladimir; Kar, Somnath; Karasu Uysal, Ayben; Karavichev, Oleg; Karavicheva, Tatiana; Karczmarczyk, Przemyslaw; Karpechev, Evgeny; Kebschull, Udo Wolfgang; Keidel, Ralf; Keijdener, Darius Laurens; Keil, Markus; Ketzer, Bernhard Franz; Khabanova, Zhanna; Khan, Ahsan Mehmood; Khan, Shaista; Khan, Shuaib Ahmad; Khanzadeev, Alexei; Kharlov, Yury; Khatun, Anisa; Khuntia, Arvind; Kielbowicz, Miroslaw Marek; Kileng, Bjarte; Kim, Byungchul; Kim, Daehyeok; Kim, Dong Jo; Kim, Eun Joo; Kim, Hyeonjoong; Kim, Jinsook; Kim, Jiyoung; Kim, Minjung; Kim, Se Yong; Kim, Taejun; Kim, Taesoo; Kirsch, Stefan; Kisel, Ivan; Kiselev, Sergey; Kisiel, Adam Ryszard; Klay, Jennifer Lynn; Klein, Carsten; Klein, Jochen; Klein-boesing, Christian; Klewin, Sebastian; Kluge, Alexander; Knichel, Michael Linus; Knospe, Anders Garritt; Kobdaj, Chinorat; Varga-kofarago, Monika; Kohler, Markus Konrad; Kollegger, Thorsten; Kondratyeva, Natalia; Kondratyuk, Evgeny; Konevskikh, Artem; Konyushikhin, Maxim; Kovalenko, Oleksandr; Kovalenko, Vladimir; Kowalski, Marek; Kralik, Ivan; Kravcakova, Adela; Kreis, Lukas; Krivda, Marian; Krizek, Filip; Kruger, Mario; Kryshen, Evgeny; Krzewicki, Mikolaj; Kubera, Andrew Michael; Kucera, Vit; Kuhn, Christian Claude; Kuijer, Paulus Gerardus; Kumar, Jitendra; Kumar, Lokesh; Kumar, Shyam; Kundu, Sourav; Kurashvili, Podist; Kurepin, Alexander; Kurepin, Alexey; Kuryakin, Alexey; Kushpil, Svetlana; Kvapil, Jakub; Kweon, Min Jung; Kwon, Youngil; La Pointe, Sarah Louise; La Rocca, Paola; Lai, Yue Shi; Lakomov, Igor; Langoy, Rune; Lapidus, Kirill; Lara Martinez, Camilo Ernesto; Lardeux, Antoine Xavier; Larionov, Pavel; Laudi, Elisa; Lavicka, Roman; Lea, Ramona; Leardini, Lucia; Lee, Seongjoo; Lehas, Fatiha; Lehner, Sebastian; Lehrbach, Johannes; Lemmon, Roy Crawford; Leon Monzon, Ildefonso; Levai, Peter; Li, Xiaomei; Li, Xing Long; Lien, Jorgen Andre; Lietava, Roman; Lim, Bong-hwi; Lindal, Svein; Lindenstruth, Volker; Lindsay, Scott William; Lippmann, Christian; Lisa, Michael Annan; Litichevskyi, Vladyslav; Liu, Alwina; Ljunggren, Hans Martin; Llope, William; Lodato, Davide Francesco; Loginov, Vitaly; Loizides, Constantinos; Loncar, Petra; Lopez, Xavier Bernard; Lopez Torres, Ernesto; Lowe, Andrew John; Luettig, Philipp Johannes; Luhder, Jens Robert; Lunardon, Marcello; Luparello, Grazia; Lupi, Matteo; Maevskaya, Alla; Mager, Magnus; Mahmood, Sohail Musa; Maire, Antonin; Majka, Richard Daniel; Malaev, Mikhail; Malik, Qasim Waheed; Malinina, Liudmila; Mal'kevich, Dmitry; Malzacher, Peter; Mamonov, Alexander; Manko, Vladislav; Manso, Franck; Manzari, Vito; Mao, Yaxian; Marchisone, Massimiliano; Mares, Jiri; Margagliotti, Giacomo Vito; Margotti, Anselmo; Margutti, Jacopo; Marin, Ana Maria; Markert, Christina; Marquard, Marco; Martin, Nicole Alice; Martinengo, Paolo; Martinez, Jacobb Lee; Martinez Hernandez, Mario Ivan; Martinez-garcia, Gines; Martinez Pedreira, Miguel; Masciocchi, Silvia; Masera, Massimo; Masoni, Alberto; Massacrier, Laure Marie; Masson, Erwann; Mastroserio, Annalisa; Mathis, Andreas Michael; Toledo Matuoka, Paula Fernanda; Matyja, Adam Tomasz; Mayer, Christoph; Mazzilli, Marianna; Mazzoni, Alessandra Maria; Meddi, Franco; Melikyan, Yuri; Menchaca-rocha, Arturo Alejandro; Meninno, Elisa; Mercado-perez, Jorge; Meres, Michal; Soncco Meza, Carlos; Mhlanga, Sibaliso; Miake, Yasuo; Micheletti, Luca; Mieskolainen, Matti Mikael; Mihaylov, Dimitar Lubomirov; Mikhaylov, Konstantin; Mischke, Andre; Mishra, Aditya Nath; Miskowiec, Dariusz Czeslaw; Mitra, Jubin; Mitu, Ciprian Mihai; Mohammadi, Naghmeh; Mohanty, Auro Prasad; Mohanty, Bedangadas; Khan, Mohammed Mohisin; Moreira De Godoy, Denise Aparecida; Perez Moreno, Luis Alberto; Moretto, Sandra; Morreale, Astrid; Morsch, Andreas; Muccifora, Valeria; Mudnic, Eugen; Muhlheim, Daniel Michael; Muhuri, Sanjib; Mukherjee, Maitreyee; Mulligan, James Declan; Gameiro Munhoz, Marcelo; Munning, Konstantin; Arratia Munoz, Miguel Ignacio; Munzer, Robert Helmut; Murakami, Hikari; Murray, Sean; Musa, Luciano; Musinsky, Jan; Myers, Corey James; Myrcha, Julian Wojciech; Naik, Bharati; Nair, Rahul; Nandi, Basanta Kumar; Nania, Rosario; Nappi, Eugenio; Narayan, Amrendra; Naru, Muhammad Umair; Nassirpour, Adrian Fereydon; Ferreira Natal Da Luz, Pedro Hugo; Nattrass, Christine; Rosado Navarro, Sebastian; Nayak, Kishora; Nayak, Ranjit; Nayak, Tapan Kumar; Nazarenko, Sergey; Negrao De Oliveira, Renato Aparecido; Nellen, Lukas; Nesbo, Simon Voigt; Neskovic, Gvozden; Ng, Fabian; Nicassio, Maria; Niedziela, Jeremi; Nielsen, Borge Svane; Nikolaev, Sergey; Nikulin, Sergey; Nikulin, Vladimir; Noferini, Francesco; Nomokonov, Petr; Nooren, Gerardus; Cabanillas Noris, Juan Carlos; Norman, Jaime; Nyanin, Alexander; Nystrand, Joakim Ingemar; Oh, Hoonjung; Ohlson, Alice Elisabeth; Oleniacz, Janusz; Oliveira Da Silva, Antonio Carlos; Oliver, Michael Henry; Onderwaater, Jacobus; Oppedisano, Chiara; Orava, Risto; Oravec, Matej; Ortiz Velasquez, Antonio; Oskarsson, Anders Nils Erik; Otwinowski, Jacek Tomasz; Oyama, Ken; Pachmayer, Yvonne Chiara; Pacik, Vojtech; Pagano, Davide; Paic, Guy; Palni, Prabhakar; Pan, Jinjin; Pandey, Ashutosh Kumar; Panebianco, Stefano; Papikyan, Vardanush; Pareek, Pooja; Park, Jonghan; Parkkila, Jasper Elias; Parmar, Sonia; Passfeld, Annika; Pathak, Surya Prakash; Patra, Rajendra Nath; Paul, Biswarup; Pei, Hua; Peitzmann, Thomas; Peng, Xinye; Pereira, Luis Gustavo; Pereira Da Costa, Hugo Denis Antonio; Peresunko, Dmitry Yurevich; Perez Lezama, Edgar; Peskov, Vladimir; Pestov, Yury; Petracek, Vojtech; Petrovici, Mihai; Petta, Catia; Peretti Pezzi, Rafael; Piano, Stefano; Pikna, Miroslav; Pillot, Philippe; Ozelin De Lima Pimentel, Lais; Pinazza, Ombretta; Pinsky, Lawrence; Pisano, Silvia; Piyarathna, Danthasinghe; Ploskon, Mateusz Andrzej; Planinic, Mirko; Pliquett, Fabian; Pluta, Jan Marian; Pochybova, Sona; Podesta Lerma, Pedro Luis Manuel; Poghosyan, Martin; Polishchuk, Boris; Poljak, Nikola; Poonsawat, Wanchaloem; Pop, Amalia; Poppenborg, Hendrik; Porteboeuf, Sarah Julie; Pozdniakov, Valeriy; Prasad, Sidharth Kumar; Preghenella, Roberto; Prino, Francesco; Pruneau, Claude Andre; Pshenichnov, Igor; Puccio, Maximiliano; Punin, Valery; Putschke, Jorn Henning; Raha, Sibaji; Rajput, Sonia; Rak, Jan; Rakotozafindrabe, Andry Malala; Ramello, Luciano; Rami, Fouad; Raniwala, Rashmi; Raniwala, Sudhir; Rasanen, Sami Sakari; Rascanu, Bogdan Theodor; Ratza, Viktor; Ravasenga, Ivan; Read, Kenneth Francis; Redlich, Krzysztof; Rehman, Attiq Ur; Reichelt, Patrick Simon; Reidt, Felix; Ren, Xiaowen; Renfordt, Rainer Arno Ernst; Reshetin, Andrey; Revol, Jean-pierre; Reygers, Klaus Johannes; Riabov, Viktor; Richert, Tuva Ora Herenui; Richter, Matthias Rudolph; Riedler, Petra; Riegler, Werner; Riggi, Francesco; Ristea, Catalin-lucian; Rode, Sudhir Pandurang; Rodriguez Cahuantzi, Mario; Roeed, Ketil; Rogalev, Roman; Rogochaya, Elena; Rohr, David Michael; Roehrich, Dieter; Rokita, Przemyslaw Stefan; Ronchetti, Federico; Dominguez Rosas, Edgar; Roslon, Krystian; Rosnet, Philippe; Rossi, Andrea; Rotondi, Alberto; Roukoutakis, Filimon; Roy, Christelle Sophie; Roy, Pradip Kumar; Vazquez Rueda, Omar; Rui, Rinaldo; Rumyantsev, Boris; Rustamov, Anar; Ryabinkin, Evgeny; Ryabov, Yury; Rybicki, Andrzej; Saarinen, Sampo; Sadhu, Samrangy; Sadovskiy, Sergey; Safarik, Karel; Saha, Sumit Kumar; Sahoo, Baidyanath; Sahoo, Pragati; Sahoo, Raghunath; Sahoo, Sarita; Sahu, Pradip Kumar; Saini, Jogender; Sakai, Shingo; Saleh, Mohammad Ahmad; Sambyal, Sanjeev Singh; Samsonov, Vladimir; Sandoval, Andres; Sarkar, Amal; Sarkar, Debojit; Sarkar, Nachiketa; Sarma, Pranjal; Sas, Mike Henry Petrus; Scapparone, Eugenio; Scarlassara, Fernando; Schaefer, Brennan; Scheid, Horst Sebastian; Schiaua, Claudiu Cornel; Schicker, Rainer Martin; Schmidt, Christian Joachim; Schmidt, Hans Rudolf; Schmidt, Marten Ole; Schmidt, Martin; Schmidt, Nicolas Vincent; Schukraft, Jurgen; Schutz, Yves Roland; Schwarz, Kilian Eberhard; Schweda, Kai Oliver; Scioli, Gilda; Scomparin, Enrico; Sefcik, Michal; Seger, Janet Elizabeth; Sekiguchi, Yuko; Sekihata, Daiki; Selyuzhenkov, Ilya; Senosi, Kgotlaesele; Senyukov, Serhiy; Serradilla Rodriguez, Eulogio; Sett, Priyanka; Sevcenco, Adrian; Shabanov, Arseniy; Shabetai, Alexandre; Shahoyan, Ruben; Shaikh, Wadut; Shangaraev, Artem; Sharma, Anjali; Sharma, Ankita; Sharma, Meenakshi; Sharma, Natasha; Sheikh, Ashik Ikbal; Shigaki, Kenta; Shimomura, Maya; Shirinkin, Sergey; Shou, Qiye; Shtejer Diaz, Katherin; Sibiryak, Yury; Siddhanta, Sabyasachi; Sielewicz, Krzysztof Marek; Siemiarczuk, Teodor; Silvermyr, David Olle Rickard; Simatovic, Goran; Simonetti, Giuseppe; Singaraju, Rama Narayana; Singh, Ranbir; Singh, Randhir; Singhal, Vikas; Sarkar - Sinha, Tinku; Sitar, Branislav; Sitta, Mario; Skaali, Bernhard; Slupecki, Maciej; Smirnov, Nikolai; Snellings, Raimond; Snellman, Tomas Wilhelm; Song, Jihye; Soramel, Francesca; Sorensen, Soren Pontoppidan; Sozzi, Federica; Sputowska, Iwona Anna; Stachel, Johanna; Stan, Ionel; Stankus, Paul; Stenlund, Evert Anders; Stocco, Diego; Storetvedt, Maksim Melnik; Strmen, Peter; Alarcon Do Passo Suaide, Alexandre; Sugitate, Toru; Suire, Christophe Pierre; Suleymanov, Mais Kazim Oglu; Suljic, Miljenko; Sultanov, Rishat; Sumbera, Michal; Sumowidagdo, Suharyo; Suzuki, Ken; Swain, Sagarika; Szabo, Alexander; Szarka, Imrich; Tabassam, Uzma; Takahashi, Jun; Tambave, Ganesh Jagannath; Tanaka, Naoto; Tarhini, Mohamad; Tariq, Mohammad; Tarzila, Madalina-gabriela; Tauro, Arturo; Tejeda Munoz, Guillermo; Telesca, Adriana; Terrevoli, Cristina; Teyssier, Boris; Thakur, Dhananjaya; Thakur, Sanchari; Thomas, Deepa; Thoresen, Freja; Tieulent, Raphael Noel; Tikhonov, Anatoly; Timmins, Anthony Robert; Toia, Alberica; Topilskaya, Nataliya; Toppi, Marco; Rojas Torres, Solangel; Tripathy, Sushanta; Trogolo, Stefano; Trombetta, Giuseppe; Tropp, Lukas; Trubnikov, Victor; Trzaska, Wladyslaw Henryk; Trzcinski, Tomasz Piotr; Trzeciak, Barbara Antonina; Tsuji, Tomoya; Tumkin, Alexandr; Turrisi, Rosario; Tveter, Trine Spedstad; Ullaland, Kjetil; Umaka, Ejiro Naomi; Uras, Antonio; Usai, Gianluca; Utrobicic, Antonija; Vala, Martin; Van Hoorne, Jacobus Willem; Van Leeuwen, Marco; Vande Vyvre, Pierre; Varga, Dezso; Diozcora Vargas Trevino, Aurora; Vargyas, Marton; Varma, Raghava; Vasileiou, Maria; Vasiliev, Andrey; Vauthier, Astrid; Vazquez Doce, Oton; Vechernin, Vladimir; Veen, Annelies Marianne; Vercellin, Ermanno; Vergara Limon, Sergio; Vermunt, Luuk; Vernet, Renaud; Vertesi, Robert; Vickovic, Linda; Viinikainen, Jussi Samuli; Vilakazi, Zabulon; Villalobos Baillie, Orlando; Villatoro Tello, Abraham; Vinogradov, Alexander; Virgili, Tiziano; Vislavicius, Vytautas; Vodopyanov, Alexander; Volkl, Martin Andreas; Voloshin, Kirill; Voloshin, Sergey; Volpe, Giacomo; Von Haller, Barthelemy; Vorobyev, Ivan; Voscek, Dominik; Vranic, Danilo; Vrlakova, Janka; Wagner, Boris; Wang, Hongkai; Wang, Mengliang; Watanabe, Yosuke; Weber, Michael; Weber, Steffen Georg; Wegrzynek, Adam; Weiser, Dennis Franz; Wenzel, Sandro Christian; Wessels, Johannes Peter; Westerhoff, Uwe; Whitehead, Andile Mothegi; Wiechula, Jens; Wikne, Jon; Wilk, Grzegorz Andrzej; Wilkinson, Jeremy John; Willems, Guido Alexander; Williams, Crispin; Willsher, Emily; Windelband, Bernd Stefan; Witt, William Edward; Xu, Ran; Yalcin, Serpil; Yamakawa, Kosei; Yano, Satoshi; Yin, Zhongbao; Yokoyama, Hiroki; Yoo, In-kwon; Yoon, Jin Hee; Yurchenko, Volodymyr; Zaccolo, Valentina; Zaman, Ali; Zampolli, Chiara; Correa Zanoli, Henrique Jose; Zardoshti, Nima; Zarochentsev, Andrey; Zavada, Petr; Zavyalov, Nikolay; Zbroszczyk, Hanna Paulina; Zhalov, Mikhail; Zhang, Xiaoming; Zhang, Yonghong; Zhang, Zuman; Zhao, Chengxin; Zherebchevskii, Vladimir; Zhigareva, Natalia; Zhou, Daicui; Zhou, You; Zhou, Zhuo; Zhu, Hongsheng; Zhu, Jianhui; Zhu, Ya; Zichichi, Antonino; Zimmermann, Markus Bernhard; Zinovjev, Gennady; Zmeskal, Johann; Zou, Shuguang

    2018-01-01

    Inclusive J/$\\psi$ production is studied in Xe-Xe interactions at a centre-of-mass energy per nucleon pair of $\\sqrt{s_{NN}}$ = 5.44 TeV, using the ALICE detector at the CERN LHC. The J/$\\psi$ meson is reconstructed via its decay into a muon pair, in the centre-of-mass rapidity interval 2.5 < y < 4 and down to zero transverse momentum. In this Letter, the nuclear modification factors $R_{AA}$ for inclusive J/$\\psi$, measured in the centrality range 0-90% as well as in the centrality intervals 0-20% and 20-90% are presented. The $R_{AA}$ values are compared to previously published results for Pb-Pb collisions at $\\sqrt{s_{NN}}$ = 5.02 TeV and to the calculation of a transport model. A good agreement is found between Xe-Xe and Pb-Pb results as well as between data and the model.

  13. Beta-gamma counting system for Xe fission products

    International Nuclear Information System (INIS)

    Reeder, P.L.; Bowyer, T.W.; Perkins, R.W.

    1998-01-01

    A beta-gamma coincidence counting system has been developed for automated analysis of Xe gas samples separated from air. The Xe gas samples are contained in a cylindrical plastic scintillator cell located between two NaI(Tl) scintillation detectors. The X-ray and gamma spectra gated by coincident events in the plastic scintillator cell are recorded for each NaI(Tl) crystal. The characteristic signatures of the 131m Xe, 133g Xe, 133m Xe, and 135g Xe isotopes of interest for nuclear test-ban verification as well as the procedures and results of absolute efficiency measurements are described. A NaI(Tl) crystal with provision for 4 sample cells has been implemented for the system to be deployed in the field. Examples of data on ambient air samples in New York City obtained with the field prototype are presented. (author)

  14. /sup 133/Xe and /sup 135/Xe interference with in vivo low-energy measurement systems

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, N; Lo Sasso, T; Lei, W [New York Univ., NY (USA). Inst. of Environmental Medicine

    1980-03-01

    Fission product /sup 133/Xe and /sup 135/Xe are released to the atmosphere during normal reactor operation. With increasing numbers of nuclear power stations there will be an increase in the ambient level of these isotopes. They do not present an appreciable long-term health hazard because of their inert nature and relatively short half-lives. However, their presence in the air of a whole-body counter may interfere significantly with in vivo low-energy photon counting procedures by contributing to the background count-rate in the energy region below 300 keV. This applies particularly to lung and whole-body measurements with dual thin crystal NaI(Tl)-CsI(Tl) scintillation detectors for actinide nuclides. It is important, therefore, that gamma spectroscopists should be aware of the possible presence of /sup 133/Xe and /sup 135/Xe in the air of their whole-body counting facilities, particularly if these are near to reactors and do not have traps for removal of inert gases from their air supplies.

  15. 5 CFR 2100.10 - Conditions of disclosure and accounting of certain disclosures.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Conditions of disclosure and accounting of certain disclosures. 2100.10 Section 2100.10 Administrative Personnel ARMED FORCES RETIREMENT HOME ARMED FORCES RETIREMENT HOME PRIVACY ACT PROCEDURES § 2100.10 Conditions of disclosure and accounting of...

  16. Molecular dynamics simulations of adsorption and diffusion of Xe on bare and Xe covered Pt(111)

    NARCIS (Netherlands)

    Jong, de F.; Jansen, A.P.J.

    1994-01-01

    Molecular dynamics simulations are used to calculate adsorption probabilities and diffusion coefficients of Xe on Pt(111) and Xe/Pt(111). Experimental trends are reproduced. The adsorption mechanism is found to be the modified Kisliuk model, with the addition of direct and indirect insertion in the

  17. SEP-Kr and SEP-Xe in Lunar Ilmenite and the Ar/Kr/Xe Ratio in the Solar Wind

    Science.gov (United States)

    Wieler, R.; Baur, H.; Signer, P.

    1992-07-01

    We analyzed all five noble gases in an ilmenite sample from lunar soil 71501 by closed system stepped etching (CSSE), thus extending our CSSE studies of solar noble gases (Wieler et al., 1986; Benkert et al., 1988) to Kr and Xe. He, Ne, Ar isotopes: We observe the familiar presence of two solar noble gas components: step 1 shows ^4He/^3He = 2250, ^20Ne/^22Ne = 13.8, and ^36Ar/^38Ar=5.46. The first two ratios are essentially identical to modern solar wind values (SWC; Geiss, 1973), indicating an isotopically unfractionated SW noble gas reservoir in lunar ilmenite. The Ne data-points of later steps fall on a straight line and reach the SEP-Ne point (^20Ne/^22Ne = 11.3). The slope of this line indicates mass dependent fractionation between SW-Ne and SEP-Ne. SEP-He (^4He/^3He = 4650 +-100) and SEP-Ar (^36Ar/^38Ar = 4.89+-0.05) are also observed (latter two numbers slightly revised compared to Wieler et al., 1992). Kr, Xe isotopes: Kr in those two steps that release pure SW-Ne is very slightly lighter than atmospheric Kr (^86Kr/^84Kr = 0.3041; see also Wieler et al., 1992). We interpret this to be SW-Kr in soil 71501. Steps containing (isotopically heavier) SEP-Ne likewise release heavier Kr, interpreted accordingly as SEP-Kr (^86Kr/^84Kr = 0.323). Similarly, a light Xe component is released first (SW-Xe, ^136Xe/^132Xe = 0.3003), followed by heavier SEP-Xe (^136Xe/^132Xe = 0.319). The data are consistent with both Kr and Xe in SW and SEP components to be related by mass fractionation. The relation first proposed by Benkert et al. (1988) between a ratio R(m(sub)2,m(sub)1) of two isotopes with masses m(sub)2>m(sub)1 in SW and SEP now holds for all five noble gases: (R(sub)SW-R(sub)SEP)/R(sub)SW = (2+-0.13)*(m(sub)2- m(sub)1)/m(sub)2. Since m(sub)2~m(sub)1, this relation may also be written as: R(sub)SEP/R(sub)SW ~ (m(sub)1/m(sub)2)^2 (Geiss and Bochsler, 1991). Element ratios: ^4He/^36Ar and ^20Ne/^36Ar rise from values several times below SWC to essentially SWC ratios in

  18. Preparation and dosimetry of reactor-produced Xe-125 for ventilation scintigraphy

    International Nuclear Information System (INIS)

    Junker, D.; Cordes, H.

    1978-01-01

    Xe-125 is produced in the reactor by the (n, γ)-reaction from Xe-124. The natural abundance of Xe-124, however, is only 0,1 percent. As the costs for Xe-124 enriched Xenon are considerable, natural Xenon is activated in the epithermal energy region. In contrast to the other stable isotopes of Xenon, Xe-124 shows a large resonance cross section in this energy region. The main activation product is Xe-125. In addition, a few nuclides (e.g. Xe-125m, Xe-127m, Xe-137) are produced, which due to their short half lives give no contribution to radiation dose. Radiocontaminants originating from parent-daughter decay (e.g. Cs-135 and Cs-137) are separated by filtration of the gas. I-125 produced by the decay of Xe-125 is removed by filtering of the gas before administration to the patient. Typical yields of a sample capsule are 20 to 30 mCi Xe-125 after irradiation of 4 hours in an epithermal flux of approximately 2.10 -11 s -1 cm -2 . The residual contaminants contributing to the radiation dose are Xe-135 and Xe-129m. Depending on the irradiation time they amount to a few percent of the total activity. Using Xe-125 for lung ventilation studies results in considerable reduction of radiation dose as compared to Xe-133. An additional advantage is the better tissue penetration of Xe-125 (γ-energies at 188 keV (55%) and 243 keV (29%)) permitting the reduction of the dose for a study. The daughter nuclide I-125 generated during the study causes only a few mrem of radiation dose if the thyroid is blocked. Altogether Xe-125 as compared to Xe-133 offers more suitable γ-energies for lung ventilation studies and in addition a reduced radiation dose to the patient. (author)

  19. Centrality determination using the Glauber model in Xe-Xe collisions at $\\sqrt{s_{\\rm NN}} = 5.44$ TeV

    CERN Document Server

    2018-01-01

    This document describes the methods used by the ALICE Collaboration for determining the centrality of Xe-Xe collisions at $\\sqrt{s_{\\rm NN}} = 5.44$ TeV at the LHC within the Glauber model. The half-density radius $R$ and the diffusivity $a$ describing the Xe-129 nucleus with a 2-parameter Fermi distribution have been derived from a recent electron scattering measurement for the Xe-132 nucleus. The deformation parameter $\\beta$ has been derived by an interpolation between measured deformation parameters for the even-$A$ Xe isotopes. The inelastic nucleon-nucleon cross-section at $\\sqrt{s_{\\rm NN}} = 5.44$ TeV has been estimated by interpolation of pp data at different center-of-mass energies. The particle multiplicity per nucleon-nucleon collision has been parameterized by a negative binomial distribution (NBD) and a number of independently emitting sources (ancestors) given by a linear combination of $N_{\\rm part}$ and $N_{\\rm coll}$. The NBD parameters $\\mu$ and $k$ and the ancestor parameter $f$ are then...

  20. Diagnosing feline infectious peritonitis using the Sysmex XT-2000iV based on frozen supernatants from cavitary effusions.

    Science.gov (United States)

    Stranieri, Angelica; Paltrinieri, Saverio; Giordano, Alessia

    2017-05-01

    The delta total nucleated cells (ΔTNC) measurement with the Sysmex XT-2000iV (Sysmex Europe, Norderstedt, Germany) has high diagnostic accuracy on effusions in feline infectious peritonitis (FIP) cases, but the test can be performed only on fresh samples. We evaluated whether supernatants from effusions retain the ability to induce cell clumping and assessed the diagnostic accuracy of this modified ΔTNC method. Effusions were collected from FIP cats ( n = 19) and from cats with other diseases ( n = 15). ΔTNC was measured on fresh samples and on frozen-thawed supernatants after the addition of feline blood at 1:10 dilution. Diagnostic accuracy was assessed at the cutoffs of suggestive of FIP (ΔTNC = 1.7) and consistent with FIP (ΔTNC = 3.4). The influence of the protein content, number of added cells, and magnitude of dilution were also investigated. Specificity and positive predictive value were 100% for both the methods. Sensitivity and negative predictive value were higher for the modified ΔTNC (84.2% and 83.3%, respectively, at the cutoff of 1.7; 78.9% and 78.9%, respectively, at the cutoff of 3.4) than for the ΔTNC on fresh samples (78.6% and 81.3%, respectively, at the cutoff of 1.7; 57.1% and 68.4%, respectively, at the cutoff of 3.4). Protein content, total cell count of the added blood, and magnitude of dilutions did not influence the results. Supernatants of frozen effusions from FIP cats retain the ability to induce cell clumping, thus the modified ΔTNC measurement is a reliable tool to diagnose FIP on samples that cannot be analyzed immediately.

  1. The Surface Reactions of Ethanol over UO2(100) Thin Film

    KAUST Repository

    Senanayake, Sanjaya D.

    2015-10-08

    The study of the reactions of oxygenates on well-defined oxide surfaces is important for the fundamental understanding of heterogeneous chemical pathways that are influenced by atomic geometry, electronic structure and chemical composition. In this work, an ordered uranium oxide thin film surface terminated in the (100) orientation is prepared on a LaAlO3 substrate and studied for its reactivity with a C-2 oxygenate, ethanol (CH3CH2OH). With the use of synchrotron X-ray photoelectron spectroscopy (XPS), we have probed the adsorption and desorption processes observed in the valence band, C1s, O1s and U4f to investigate the bonding mode, surface composition, electronic structure and probable chemical changes to the stoichiometric-UO2(100) [smooth-UO2(100)] and Ar+-sputtered UO2(100) [rough-UO2(100)] surfaces. Unlike UO2(111) single crystal and UO2 thin film, Ar-ion sputtering of this UO2(100) did not result in noticeable reduction of U cations. The ethanol molecule has C-C, C-H, C-O and O-H bonds, and readily donates the hydroxyl H while interacting strongly with the UO2 surfaces. Upon ethanol adsorption (saturation occurred at 0.5 ML), only ethoxy (CH3CH2O-) species is formed on smooth-UO2(100) whereas initially formed ethoxy species are partially oxidized to surface acetate (CH3COO-) on the Ar+-sputtered UO2(100) surface. All ethoxy and acetate species are removed from the surface between 600 and 700 K.

  2. The Surface Reactions of Ethanol over UO2(100) Thin Film

    KAUST Repository

    Senanayake, Sanjaya D.; Mudiyanselage, Kumudu; Burrell, Anthony K; Sadowski, Jerzy T.; Idriss, Hicham

    2015-01-01

    The study of the reactions of oxygenates on well-defined oxide surfaces is important for the fundamental understanding of heterogeneous chemical pathways that are influenced by atomic geometry, electronic structure and chemical composition. In this work, an ordered uranium oxide thin film surface terminated in the (100) orientation is prepared on a LaAlO3 substrate and studied for its reactivity with a C-2 oxygenate, ethanol (CH3CH2OH). With the use of synchrotron X-ray photoelectron spectroscopy (XPS), we have probed the adsorption and desorption processes observed in the valence band, C1s, O1s and U4f to investigate the bonding mode, surface composition, electronic structure and probable chemical changes to the stoichiometric-UO2(100) [smooth-UO2(100)] and Ar+-sputtered UO2(100) [rough-UO2(100)] surfaces. Unlike UO2(111) single crystal and UO2 thin film, Ar-ion sputtering of this UO2(100) did not result in noticeable reduction of U cations. The ethanol molecule has C-C, C-H, C-O and O-H bonds, and readily donates the hydroxyl H while interacting strongly with the UO2 surfaces. Upon ethanol adsorption (saturation occurred at 0.5 ML), only ethoxy (CH3CH2O-) species is formed on smooth-UO2(100) whereas initially formed ethoxy species are partially oxidized to surface acetate (CH3COO-) on the Ar+-sputtered UO2(100) surface. All ethoxy and acetate species are removed from the surface between 600 and 700 K.

  3. FIRE! A Red Flag Tap in Reclaiming Intervention

    Science.gov (United States)

    Bodnar, Brian

    2007-01-01

    "Red Flag Interventions" address problems which are imported from elsewhere and acted out towards persons who are in effect innocent bystanders. This is commonly seen as students "carry in" problems from the home or street to school, or they "carry over" conflicts from one class to the next. A third variation of Red Flag intervention is when a…

  4. Xe-129 NMR chemical shift in Xe@C-60 calculated at experimental conditions: Essential role of the relativity, dynamics, and explicit solvent

    Czech Academy of Sciences Publication Activity Database

    Standara, Stanislav; Kulhánek, P.; Marek, R.; Straka, Michal

    2013-01-01

    Roč. 34, č. 22 (2013), s. 1890-1898 ISSN 0192-8651 R&D Projects: GA ČR GA203/09/2037; GA ČR GA13-03978S Grant - others:7th European Community Framework Program(XE) FP7-286154; CEITEC-Central European Institute of Technology (European Regional Development)(XE) CZ.1.05/1.1.00/02.0068; Operational Program Research and Development for Innovations(XE) CZ.1.05/3.2.00/08.0144 Institutional support: RVO:61388963 Keywords : Xe-129 NMR * Xe@C-60 * dynamical averaging * explicit solvent * relativistic effects Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 3.601, year: 2013

  5. Production of pure 133mXe for CTBTO

    Science.gov (United States)

    Peräjärvi, K.; Eronen, T.; Gorelov, D.; Hakala, J.; Jokinen, A.; Kettunen, H.; Kolhinen, V.; Laitinen, M.; Moore, I. D.; Penttilä, H.; Rissanen, J.; Saastamoinen, A.; Toivonen, H.; Turunen, J.; Äystö, J.

    2014-01-01

    Underground nuclear weapon detonations release gaseous species into the atmosphere. The most interesting isotopes/isomers from the detection point of view are 131mXe, 133mXe, 133Xe and 135Xe. We have developed a method that employs high-precision Penning trap mass spectrometry at the JYFLTRAP facility, the University of Jyväskylä, to produce pure calibration samples of these isotopes/isomers. Among developments this work required a new mass resolution record of a few parts-per-million. Here the status and future plans of the project are reviewed.

  6. Experimental investigation of flow field around the elastic flag flapping in periodic state

    Science.gov (United States)

    Jia, Yongxia; Jia, Lichao; Su, Zhuang; Yuan, Huijing

    2018-05-01

    The flapping of a flag in the wind is a classical fluid-structure problem that concerns the interaction of elastic bodies with ambient fluid. We focus on the desirable experimental results of the flow around the flapping flag. By immersing the elastic yet self-supporting heavy flag into water flow, we use particle image velocimetry (PIV) techniques to obtain the whole flow field around the midspan of the flag interacting with a fluid in periodic state. A unique PIV image processing method is used to measure near-wall flow velocities around a moving elastic flag. There exists a thin flow circulation region on the suction side of the flag in periodic state. This observation suggests that viscous flow models may be needed to improve the theoretical predictions of the flapping flag in periodic state, especially in a large amplitude.

  7. High spin {gamma}-ray spectroscopy of {sup 121,122}Xe

    Energy Technology Data Exchange (ETDEWEB)

    Timmers, H [Liverpool Univ. (United Kingdom). Oliver Lodge Lab.; [Department of Physics, SUNY at Stony Brook, NY (United States); Riley, M A; Hanna, F; Mullins, S M; Sharpey-Schafer, J F [Liverpool Univ. (United Kingdom). Oliver Lodge Lab.; Hughes, J R; Fossan, D B; Liang, Y; Ma, R; Xu, N [Department of Physics, SUNY at Stony Brook, NY (United States); Simpson, J; Bentley, M A [Daresbury Lab. (United Kingdom); Bengtsson, T [Lund Univ. (Sweden). Dept. of Mathematical Physics; Wyss, R [Institute for Heavy Ion Research, Oak Ridge, TN (United States)

    1992-08-01

    High-spin states have been populated in {sup 121,122}Xe using the reactions {sup 108}Pd({sup 16}O,3n){sup 121}Xe at 65 MeV and {sup 96}Zr({sup 30}Si,4n/5n){sup 122}Xe/{sup 121}Xe at 135 MeV. Coincident {gamma} rays following the neutron evaporation were detected by six Compton-suppressed Ge detectors and the TESSA3 array respectively. The level structure of {sup 121}Xe and {sup 122}Xe has been extended up to 47/2 {Dirac_h} and 32 {Dirac_h} respectively. In {sup 121}Xe a coupled band was found feeding the 19/2{sup -} level. In {sup 122}Xe several decays are suggested to be a sequence of stretched E2 quadrupole transitions connecting states of positive parity. While in {sup 121}Xe this phenomenon was not observed, at high spin a phase transition from prolate collective rotation to oblate single particle excitation was detected in {sup 122}Xe. For the new, probably positive parity side band in{sup 122}Xe a four quasi-neutron or a two quasi-proton configuration of h{sub 11/2} quasi-nucleons might be considered. The positive parity high spin structure in {sup 122}Xe contains three I{sup {pi}} = 22{sup +} states of different character. This is predicted by TRS (total Routhian surface) calculations, which identify these states as two shapes with predominantly prolate collective characteristic and the third as an oblate single particle configuration. 12 refs., 3 figs.

  8. Formation of (Xe2H)* centers in solid Xe via recombination: nonstationary luminescence and 'internal electron emission'

    International Nuclear Information System (INIS)

    Savchenko, E.V.; Khyzhniy, I.V.; Uyutov, S.A.; Gumenchuk, G.B.; Ponomarev, A.N.; Bondybey, V.E.; Beyer, M.K.

    2010-01-01

    The formation of excimers (Xe 2 H) * in solid Xe doped with molecular hydrogen under electron beam is studied using the original two-stage technique of nonstationary (NS) cathodoluminescence (CL) in combination with the current activation spectroscopy method - thermally stimulated exoelectron emission (TSEE). Charged species were generated using a high-density electron beam. The species produced were then probed with a low density beam on gradual sample heating. The near UV emission of the (Xe 2 H) * was used to monitor the neutralization process. It is found that the temperature behavior of the NS CL band of (Xe 2 H) * clearly correlates with the yield of TSEE measured after identical pre-irradiation of the sample. The fingerprints of the thermally stimulated detrapping of electrons - 'internal electron emission' in the spectrum of NS CL point to the essential role of neutralization reaction in the stability of the proton solvated by rare-gas atoms.

  9. Modification of the Xe 4d giant resonance by the C60 shell in molecular Xe at C60

    International Nuclear Information System (INIS)

    Amusia, M. Ya.; Baltenkov, A. S.; Chernysheva, L. V.; Felfli, Z.; Msezane, A. Z.

    2006-01-01

    It is demonstrated that in photoabsorption of the 4d 10 subshell of a Xe atom in molecular Xe at C 60 , the 4d giant resonance that characterizes the isolated Xe atom is distorted significantly. The reflection of photoelectron waves by the C 60 shell leads to profound oscillations in the photoionization cross section such that the Xe giant resonance is transformed into four strong peaks. Similarly, the angular anisotropy parameters, both dipole and nondipole, are also modified. The method of calculation is based on the approximation of the C 60 shell by an infinitely thin bubble potential that leaves the sum rule for the 4d-electrons almost unaffected, but noticeably modifies the dipole polarizability of the 4d-shell

  10. 136 Xe enrichment through cryogenic distillation

    Energy Technology Data Exchange (ETDEWEB)

    Back, Henning O.; Bottenus, Daniel R.; Clayton, Christopher K.; Stephenson, David E.; TeGrotenhuis, Ward E.

    2017-09-01

    The next generation of 136Xe neutrinoless double beta decay experiments will require on the order of 5 tons of enriched 136Xe. By estimating the relative volatilities of the xenon isotopes and using standard chemical engineering techniques we explore the feasibility of using cryogenic distillation to produce 5 tons of 80% enriched 136Xe in 5-6 years. With current state-of-the-art distillation column packing materials we can estimate the total height of a traditional cryogenic distillation column. We also, report on how Micro Channel Distillation may reduce the overall size of a distillation system for 136Xe production.

  11. Recoil distance lifetime measurements in 122,124Xe

    Science.gov (United States)

    Govil, I. M.; Kumar, A.; Iyer, H.; Li, H.; Garg, U.; Ghugre, S. S.; Johnson, T.; Kaczarowski, R.; Kharraja, B.; Naguleswaran, S.; Walpe, J. C.

    1998-02-01

    Lifetimes of the lower-excited states in 122,124Xe are measured using the recoil-distance Doppler-shift technique. The reactions 110Pd(16O,4n)122Xe and 110Pd(18O,4n)124Xe at a beam energy of 66 MeV were used for this experiment. The lifetimes of the 2+, 4+, 6+, and 8+ states of the ground state band were extracted using the computer code LIFETIME including the corrections due to the side feeding and the nuclear deorientation effects. The lifetime of the 2+ state in 122Xe agrees with the recoil distance method (RDM) measurements but for the 124Xe it does not agree with the RDM measurements but agrees with the Coulomb-excitation experiment. The measured B(E2) values for both the nuclei are compared with the standard algebraic and the multishell models.

  12. Asymmetric output profile of Xe Laser

    NARCIS (Netherlands)

    Blok, F.J.; Rubin, P.L.; Verschuur, Jeroen W.J.; Witteman, W.J.

    2001-01-01

    A new set of asymmetric modes was recently revealed in a Xe slab laser with pronounced lens effects originating from gas heating in the discharge. The appearance of these modes is a threshold effect. Their domain of existence in the Xe laser is discussed. It is shown that mode competition can result

  13. Timing of Peripheral Blood Stem Cell Yield: Comparison of Alternative Methods with the Classic Method for CD34+ Cell Determination

    Directory of Open Access Journals (Sweden)

    I. Fatorova

    2014-01-01

    Full Text Available Hematopoietic stem cells (HSCs, still represent a certain mystery in biology, have a unique property of dividing into equal cells and repopulating the hematopoietic tissue. This potential enables their use in transplantation treatments. The quality of the HSC grafts for transplantation is evaluated by flow cytometric determination of the CD34+ cells, which enables optimal timing of the first apheresis and the acquisition of maximal yield of the peripheral blood stem cells (PBSCs. To identify a more efficient method for evaluating CD34+ cells, we compared the following alternative methods with the reference method: hematopoietic progenitor cells (HPC enumeration (using the Sysmex XE-2100 analyser, detection of CD133+ cells, and quantification of aldehyde dehydrogenase activity in the PBSCs. 266 aphereses (84 patients were evaluated. In the preapheretic blood, the new methods produced data that were in agreement with the reference method. The ROC curves have shown that for the first-day apheresis target, the optimal predictive cut-off value was 0.032 cells/mL for the HPC method (sensitivity 73.4%, specificity 69.3%. HPC method exhibited a definite practical superiority as compared to other methods tested. HPC enumeration could serve as a supplementary method for the optimal timing of the first apheresis; it is simple, rapid, and cheap.

  14. High-j neutron excitations outside 136Xe

    Science.gov (United States)

    Talwar, R.; Kay, B. P.; Mitchell, A. J.; Adachi, S.; Entwisle, J. P.; Fujita, Y.; Gey, G.; Noji, S.; Ong, H. J.; Schiffer, J. P.; Tamii, A.

    2017-08-01

    The ν 0 h9 /2 and ν 0 i13 /2 strength at 137Xe, a single neutron outside the N =82 shell closure, has been determined using the 136Xe(α ,3He)137Xe reaction carried out at 100 MeV. We confirm the recent observation of the second 13 /2+ state and reassess previous data on the 9 /2- states, obtaining spectroscopic factors. These new data provide additional constraints on predictions of the same single-neutron excitations at 133Sn.

  15. Charged-particle nuclear modification factors in XeXe collisions at $\\sqrt{s_{\\mathrm{NN}}}=5.44~\\mathrm{TeV}$

    CERN Document Server

    CMS Collaboration

    2018-01-01

    The differential yields of charged particles having pseudorapidity within $|\\eta|6~\\mathrm{GeV}$. However, the suppression in XeXe events is slightly greater than in PbPb collisions when comparing selections having a similar number of participating nucleons.

  16. Experimental ion mobility measurements in Xe-CF4 mixtures

    Science.gov (United States)

    Cortez, A. F. V.; Kaja, M. A.; Escada, J.; Santos, M. A. G.; Veenhof, R.; Neves, P. N. B.; Santos, F. P.; Borges, F. I. G. M.; Conde, C. A. N.

    2018-04-01

    In this paper we present the results of the ion mobility measurements made in gaseous mixtures of xenon with carbon tetrafluoride (Xe-CF4) for pressures ranging from 6 to 10 Torr (8-10.6 mbar) and for low reduced electric fields in the 10 to 25 Td range (2.4-6.1 kVṡcm‑1ṡbar‑1), at room temperature. The time-of-arrival spectra revealed one or two peaks depending on the gas relative abundances, which were attributed to CF3+ and to Xe2+ ions. However, for Xe concentrations above 60%, only one peak remains (Xe2+). The reduced mobilities obtained from the peak centroid of the time-of-arrival spectra are presented for Xe concentrations in the 5%-95% range.

  17. Stable Chloro- and Bromoxenate Cage Anions; [X3(XeO3)3]3- and [X4(XeO3)4]4- (X = Cl or Br).

    Science.gov (United States)

    Goettel, James T; Haensch, Veit G; Schrobilgen, Gary J

    2017-06-28

    The number of isolable compounds which contain different noble-gas-element bonds is limited for xenon and even more so for krypton. Examples of Xe-Cl bonds are rare, and prior to this work, no Xe-Br bonded compound had been isolated in macroscopic quantities. The syntheses, isolation, and characterization of the first compounds to contain Xe-Br bonds and their chlorine analogues are described in the present work. The reactions of XeO 3 with [N(CH 3 ) 4 ]Br and [N(C 2 H 5 ) 4 ]Br have provided two bromoxenate salts, [N(C 2 H 5 ) 4 ] 3 [Br 3 (XeO 3 ) 3 ] and [N(CH 3 ) 4 ] 4 [Br 4 (XeO 3 ) 4 ], in which the cage anions have Xe-Br bond lengths that range from 3.0838(3) to 3.3181(8) Å. The isostructural chloroxenate anions (Xe-Cl bond lengths, 2.9316(2) to 3.101(4) Å) were synthesized by analogy with their bromine analogues. The bromo- and chloroxenate salts are stable in the atmosphere at room temperature and were characterized in the solid state by Raman spectroscopy and low-temperature single-crystal X-ray diffraction, and in the gas phase by quantum-chemical calculations. They are the only known examples of cage anions that contain a noble-gas element. The Xe-Br and Xe-Cl bonds are very weakly covalent and can be viewed as σ-hole interactions, similar to those encountered in halogen bonding. However, the halogen atoms in these cases are valence electron lone pair donors, and the σ* Xe-O orbitals are lone pair acceptors.

  18. Level structures of 119Xe, 121Xe excited in (12C,3nγ) reactions and analysis of the hsub(11/2) bands in the IBF model

    International Nuclear Information System (INIS)

    Barci, V.; Gizon, J.; Gizon, A.

    1982-02-01

    Levels in 119 Xe, 121 Xe excited by the reactions 110 Cd, 112 Cd( 12 C,3nγ) 119 Xe, 121 Xe have been studied by in-beam γ-ray spectroscopic techniques. Several bands have been observed: hsub(11/2) and gsub(7/2) in 119 Xe, 121 Xe, a decoupled one in 121 Xe. A new level structure in 119 Xe found for the first time is assigned as the gsub(9/2) band generated by one hole in the gsub(9/2) neutron shell. The connections between these bands have been fixed in both nuclei. A detailed analysis is made for the hsub(11/2) level structure. An interpretation is given in terms of the interacting boson-fermion model where hsub(11/2), fsub(7/2) and hsub(9/2) fermion configurations are included

  19. Predictions for multiplicities and flow harmonics in 5.44 TeV Xe+Xe collisions at the CERN Large Hadron Collider

    Science.gov (United States)

    Eskola, K. J.; Niemi, H.; Paatelainen, R.; Tuominen, K.

    2018-03-01

    We present the event-by-event next-to-leading-order perturbative-QCD + saturation + viscous hydrodynamics (EKRT) model predictions for the centrality dependence of the charged hadron multiplicity in the pseudorapidity interval |η |≤0.5 , and for the centrality dependence of the charged hadron flow harmonics vn{2 } obtained from two-particle cumulants, in √{sN N}=5.44 TeV Xe+Xe collisions at the CERN Large Hadron Collider. Our prediction for the 0-5 % central charged multiplicity is d Nch/d η =1218 ±46 . We also predict vn{2 } in Xe+Xe collisions to increase more slowly from central towards peripheral collisions than those in a Pb+Pb system. We find that at 10 ,⋯,50 % centralities v2{2 } is smaller and v3{2 } is larger than in the Pb+Pb system while v4{2 } is of the same magnitude in both systems. We also find that the ratio of flow harmonics in Xe+Xe collisions and in Pb+Pb collisions shows a slight sensitivity to the temperature dependence of the shear-viscosity-to-entropy ratio. As we discuss here, the new nuclear mass-number systematics especially in the flow harmonics serves as a welcome further constraint for describing the space-time evolution of a heavy-ion system and for determining the shear viscosity and other transport properties of strongly interacting matter.

  20. Search for a permanent Xe-electric dipole moment

    Energy Technology Data Exchange (ETDEWEB)

    Zimmer, Stefan [Institut fuer Physik, Universitaet Mainz (Germany); Collaboration: MIXed-Collaboration

    2016-07-01

    A permanent electric dipole moment (EDM) of the isotope {sup 129}Xe would imply a breakdown of both parity P and time-reversal symmetry T and, through the CPT theorem, a breakdown in CP, the combined symmetries of charge conjugation C and parity P. Our goal is to improve the present experimental limit (d{sub Xe}<3.10{sup -27} ecm) by about three orders of magnitude. The most precise EDM limit on diamagnetic atoms was measured on {sup 199}Hg (d{sub Hg}<3.1.10{sup -29} ecm). To get more stringent limits, we perform a {sup 3}He/{sup 129}Xe clock comparison experiment with the detection of free spin precession of gaseous, nuclear polarized {sup 3}He or {sup 129}Xe samples with a SQUID as magnetic flux detector. The precession of co-located {sup 3}He/{sup 129}Xe nuclear spins are used as an ultra-sensitive probe for non-magnetic spin interactions of type δν∝ d{sub Xe}.E. With our experimental setup at the research center Juelich we are able to observe spin coherence times T{sub 2}{sup *} of several hours for both species. We report on first experimental results achieved within the MIXed-collaboration.

  1. Beta-delayed proton emitter $^{113}Xe$

    CERN Document Server

    Hagberg, E; Jonson, B; Jørgensen, B; Kugler, E; Mowinckel, T

    1973-01-01

    The ISOLDE facility at the CERN synchrocyclotron has been used for extending the series of beta -delayed proton emitters in xenon to masses lighter than those previously observed (/sup 115,117/Xe). Owing to the rapid decrease of the yields, experiments with solid-state counters were inconclusive, and instead a new and much more sensitive method based on nuclear emulsions was developed. The mass range 111-114 showed one new activity, /sup 113/Xe, with a half-life of 2.8+or-0.2 sec. From measurements of the track lengths for a total of 1130 protons from /sup 113/Xe it was possible to determine the energy spectrum. The results extend the systematics of beta -strength functions in the light xenon isotopes. (19 refs).

  2. Brain Imaging Using Hyperpolarized 129Xe Magnetic Resonance Imaging.

    Science.gov (United States)

    Chahal, Simrun; Prete, Braedan R J; Wade, Alanna; Hane, Francis T; Albert, Mitchell S

    2018-01-01

    Hyperpolarized (HP) 129 Xe magnetic resonance imaging (MRI) is a novel iteration of traditional MRI that relies on detecting the spins of 1 H. Since 129 Xe is a gaseous signal source, it can be used for lung imaging. Additionally, 129 Xe dissolves in the blood stream and can therefore be detectable in the brain parenchyma and vasculature. In this work, we provide detailed information on the protocols that we have developed to image 129 Xe within the brains of both rodents and human subjects. © 2018 Elsevier Inc. All rights reserved.

  3. Hyperpolarized 129Xe as an NMR probe for functional studies

    International Nuclear Information System (INIS)

    Wolber, J.

    2000-01-01

    The nuclear spin polarization of 129 Xe can be enhanced by several orders of magnitude using optical pumping techniques, resulting in a dramatic enhancement of the 129 Xe Nuclear Magnetic Resonance (NMR) signal. The 'hyperpolarized' gas can be used for Magnetic Resonance Imaging (MRI) of the void spaces of the lungs after introduction of the gas into the respiratory system. Furthermore, the high solubility of xenon in blood and lipids suggests the use of 129 Xe NMR for studying blood flow, permeability, perfusion and blood volume. Hyperpolarized 129 Xe MRI has the potential of combining the high sensitivity and functional information of radioactive tracer studies with the high spatial and temporal resolution of MRI. The spin-lattice relaxation time T 1 of 129 Xe in blood determines the loss of polarization during transit from the lungs to the tissue of interest. A difference in the relaxation times of xenon in oxygenated and deoxygenated blood could be used as a contrast mechanism in functional Magnetic Resonance Imaging (fMRI). In this thesis, the hyperpolarized 129 Xe T 1 in human blood is measured in vitro as a function of blood oxygenation, and the relevant relaxation mechanisms are discussed. A new and unexpected finding is that the hyperpolarized 129 Xe NMR spectrum in blood is highly sensitive to blood oxygenation. Therefore, hyperpolarized 129 Xe NMR provides a powerful means of measuring blood oxygenation quantitatively and non-invasively. The interaction of xenon with hemoglobin is responsible for an oxygen-dependent shift of the 129 Xe NMR resonance of xenon in red blood cells. Injection delivery of hyperpolarized 129 Xe in solution could be a more efficient method of administrating the gas for functional NMR studies. For this purpose, suitable biocompatible carrier media have been studied. In particular, the use of perfluorocarbon emulsions, which are already in use as blood substitutes, as delivery media for hyperpolarized 129 Xe has been investigates

  4. I-Xe dating of silicate and troilite from IAB iron meteorites

    International Nuclear Information System (INIS)

    Niemeyer, S.

    1979-01-01

    Silicate and troilite (FeS) from IAB irons were analyzed by the I-Xe technique. Four IAB silicate samples gave well-defined I-Xe ages [in millions of years relative to Bjurbole: - 3.7 +- 0.3 for Woodbine, -0.7 +- 0.6 for Mundrabilla, + 1.4 +- 0.7 for Copiapo, and +2.6 +- 0.6 for Landes. The ( 129 Xe/ 132 Xe)sub(trapped) ratios are consistent with previous values for chondrites, with the exception of Landes which has an extraordinary trapped ratio of 3.5 +- 0.2. Both analyses of silicate from Pitts gave anomalous I-Xe patterns. Troilite samples were also analyzed: Pitts troilite gave a complex I-Xe pattern, which suggests an age of +17 Myr; Mundrabilla troilite defined a good I-Xe correlation, which after correction for neutron capture on 128 Te gave an age of -10.8 +- 0.7 Myr. Thus, low-melting troilite predates high-melting silicate in Mundrabilla. Abundances of Ga, Ge, and Ni in metal from these meteorites are correlated with I-Xe ages of the silicate; meteorites with older silicates have greater Ni contents. No model easily accounts for this result as well as other properties of IAB irons; nevertheless, these results, taken at face value, favour a nebular formation model. The great age of troilite from Mundrabilla suggests that this troilite formed in a different nebular region from the silicate and metal, and was later mechanically mixed with these other phases. The correlation between the trace elements in the metal and the I-Xe ages of the silicate provides one of the first known instances in which another well-defined meteoritic property correlates with I-Xe ages. In addition, almost all the 129 Xe in Mundrabilla silicate (etched in acid) was correlated with 128 Xe. These two results further support the validity of the I-Xe dating method. (author)

  5. A Rotational Crofton Formula for Flagged Intrinsic Volumes of Sets of Positive Reach

    DEFF Research Database (Denmark)

    Auneau, Jeremy Michel

    A rotational Crofton formula is derived relating the flagged intrinsic volumes of a compact set of positive reach with the flagged intrinsic volumes measured on sections passing through a fixed point. In particular cases, the flagged intrinsic volumes defined in the present paper are identical...

  6. Discharge characteristics of He-Ne-Xe gas mixture with varying Xe contents and at varying sustain electrode gap lengths in the plasma display panel

    International Nuclear Information System (INIS)

    Kwon, Ohyung; Whang, Ki-Woong; Bae, Hyun Sook

    2009-01-01

    The discharge characteristics of He-Ne-Xe gas mixture in the plasma display panel were investigated using a two-dimensional numerical simulation to understand the effects of adding He and varying the Xe contents in the gas mixture, and also varying sustain electrode gap. With 5% Xe content and 60 μm sustain electrode gap, decreased ionization led to the improvement of the vacuum ultraviolet (vuv) efficacy at increasing He mixing ratios. However, at 20% Xe content and 60 μm sustain electrode gap, increased electron heating improved the vuv efficacy until the He mixing ratio reached 0.7, but the efficacy decreased beyond the ratio of 0.7 due to the increased ionization of Xe atoms. At 5% Xe content and 200 μm sustain electrode gap, the vuv efficacy increased as a result of increased electron heating at the gap space at increasing He mixing ratios.

  7. Origin of anomalous Xe-H in nanodiamond stardust

    Energy Technology Data Exchange (ETDEWEB)

    Kratz, K. L. [Max-Planck-Institut für Chemie, Otto-Hahn-Institut, D-55128 Mainz, Germany and Fachbereich Chemie, Pharmazie und Geowissenschaften, Universitat Mainz, Mainz (United States); Farouqi, K. [Max-Planck-Institut für Chemie, Otto-Hahn-Institut, D-55128 Mainz, Germany and Zentrum für Astronomie der Universität Heidelberg, D-69120 Heidelberg (Germany); Hallmann, O. [Max-Planck-Institut für Chemie, Otto-Hahn-Institut, D-55128 Mainz (Germany); Pfeiffer, B. [II. Physikalisches Institut, Univ. Giessen, D-35392 Giessen (Germany); Ott, U. [Max-Planck-Institut für Chemie, Otto-Hahn-Institut, D-55128 Mainz (Germany); Univ. of West Hungary, H-9700 Szombathely (Hungary)

    2014-05-09

    Still today, the nucleosynthesis origin of Xe-H in presolar nanodiamonds is far from understood. Historically possible explanations were proposed by a secondary “neutron-burst” process occurring in the He- or C/O-shells of a type-II supernova (SN-II), which are, however, not fully convincing in terms of modern nucleosynthesis conditions. Therefore, we have investigated Xe isotopic abundance features that may be diagnostic for different versions of a classical, primary r-process in high-entropy-wind (HEW) ejecta of core-collapse SN-II. We report here on parameter tests for non-standard r-process variants, by varying electron abundances (Y{sub e}), ranges of entropies (S) and expansion velocities (V{sub exp}) with their correlated neutron-freezeout times (τ(freeze)) and temperatures (T{sub 9}(freeze)). From this study, we conclude that a best fi to the measured Xe-H abundance ratios {sup i}Xe/{sup 136}Xe can be obtained with the high-S “main” component of a “cold” r-process variant.

  8. Support for the Confederate Battle Flag in the Southern United States: Racism or Southern Pride?

    Directory of Open Access Journals (Sweden)

    Joshua D. Wright

    2017-05-01

    Full Text Available Supporters of the Confederate battle flag often argue that their support is driven by pride in the South, not negative racial attitudes. Opponents of the Confederate battle flag often argue that the flag represents racism, and that support for the flag is an expression of racism and an attempt to maintain oppression of Blacks in the Southern United States. We evaluate these two competing views in explaining attitudes toward the Confederate battle flag in the Southern United States through a survey of 526 Southerners. In the aggregate, our latent variable model suggests that White support for the flag is driven by Southern pride, political conservatism, and blatant negative racial attitudes toward Blacks. Using cluster-analysis we were able to distinguish four distinct sub-groups of White Southerners: Cosmopolitans, New Southerners, Traditionalists, and Supremacists. The greatest support for the Confederate battle flag is seen among Traditionalists and Supremacists; however, Traditionalists do not display blatant negative racial attitudes toward Blacks, while Supremacists do. Traditionalists make up the majority of Confederate battle flag supporters in our sample, weakening the claim that supporters of the flag are generally being driven by negative racial attitudes toward Blacks.

  9. Half-life of Xe120

    Science.gov (United States)

    Phillips, A. A.; Andreoiu, C.; Ball, G. C.; Bandyopadhyay, D.; Behr, J. A.; Chupp, T. E.; Finlay, P.; Garrett, P. E.; Grinyer, G. F.; Hackman, G.; Hayden, M. E.; Hyland, B.; Nuss-Warren, S. R.; Pearson, M. R.; Schumaker, M. A.; Smith, M. B.; Svensson, C. E.; Tardiff, E. R.; Valiente-Dobón, J. J.; Warner, T.

    2006-08-01

    We have measured the half-life of Xe120 using a high-purity germanium (HPGe) detector to monitor the 176, 178, and 762 keV γ rays from Xe120 β+ decay. The result, 46±0.6 min, differs significantly from the value 40±1 min reported by Andersson [Ark. Fys. 28, 37 (1964)]. We have also measured the half-lives of Cs120 and I120 to be 60±0.7 s and 82.1±0.6 min, respectively, both of which are consistent with previous measurements.

  10. Exposure to the American flag polarizes democratic-republican ideologies.

    Science.gov (United States)

    Chan, Eugene Y

    2017-12-01

    Some prior research has suggested that exposure to the American flag tilts Americans towards Republicanism, while others have proffered that it brings outs a common 'together' perspective instead. We explore a third possibility - that it may actually polarize Americans' political ideology. It is generally accepted that exposure to an environmental cue can shift attitudes and behaviours, at least partly or temporarily, in a manner that is consistent with that cue. Yet, the same cue can mean different things to different people. In the same vein, given how national identity and political ideology are intertwined in the United States, we hypothesize that the American flag should heighten different political beliefs depending on individuals' political ideology. To Democrats, being American is to support Democratic values, but to Republicans, being American is to support Republican values. The American flag thus should heighten Democrats of their Democratic identity, and it should heighten Republicans of their Republican one. The results of an experiment with 752 American respondents who were representative of the US population supported this polarizing effect of the American flag. The theoretical and policy implications of the findings are offered. © 2017 The British Psychological Society.

  11. Measurement of the azimuthal anisotropy of charged particle production in Xe+Xe collisions at $\\sqrt{s_{\\mathrm{NN}}}$=5.44~TeV with the ATLAS detector

    CERN Document Server

    The ATLAS collaboration

    2018-01-01

    This note describes the measurement of flow harmonics $v_2$--$v_5$ in Xe+Xe collisions at $\\sqrt{s_{\\mathrm{NN}}}$=5.44~TeV performed using the ATLAS detector at the LHC. The measurements are performed using multi-particle correlations involving 2, 4 and 6 particles and the Scalar Product technique. Measurements of the centrality and $p_{\\mathrm{T}}$ dependence of the $v_n$ are presented. Comparisons of the measured $v_n$ to previous measurements for Pb+Pb collisions at $\\sqrt{s_{\\mathrm{NN}}}$=5.02~TeV are also presented. The Xe+Xe $v_n$ are observed to be larger than the Pb+Pb $v_n$ for $n$=2,3 and $4$ in the most central events, but with decreasing centrality or increasing harmonic order $n$, the Xe+Xe $v_n$ become smaller than the Pb+Pb $v_n$. The Xe+Xe and Pb+Pb comparisons are also shown as a function of the mean number of participants $\\langle N_\\text{part} \\rangle$, and the 4-particle cumulants for higher-order harmonics -- $v_3\\{4\\}$ and $v_4\\{4\\}$ -- are found to scale better with $\\langle N_\\text{p...

  12. Flags of the night sky when astronomy meets national pride

    CERN Document Server

    Bordeleau, André G

    2014-01-01

    Many national flags display astronomical features–Sun, Moon, stars–but are they really based on existing astronomical objects? The United States flag sports 50 stars, one for each state, however none of them are linked to real stars. Further, the lunar crescent is often shaped like the Sun being eclipsed by the Moon. At times, stars are seen right next to the crescent, where the darkened disc of the moon should be! This book will present true astronomical objects and patterns highlighted on national flags and link informative capsules about these objects to the political reasons why they were chosen to adorn such an important symbol.

  13. EUV emission from Kr and Xe capillary discharge plasmas

    International Nuclear Information System (INIS)

    Juschkin, L.; Ellwi, S.; Kunze, H-J.; Chuvatin, A.; Zakharov, S.V.

    2002-01-01

    Kr and Xe plasmas are very intensive emitters in the spectral range of 100-150 A, which is relevant for a number of applications (for example microlithography). We present investigations of the extreme utraviolet (EUV) emission from a slow capillary discharge with Kr and Xe fillings. The emission of Kr ions (Kr VIII to Kr XI) within the range of 70-150 A consists of three bands of lines of about 10 A width with maxima at 116, 103 and 86 A. Xe emission bands of about 15 A width have their maxima at 136 and 115 A (Xe IX to Xe XII). The radiation duration in this spectral range is ∼150 ns for both elements. At the optimum conditions, the Kr emission at 103 A is 2-3 times more intense than the Xe emission at 136 A. The measured spectral energy of Kr radiation is about 0.1 J sr -1 A -1 . Experimental results are compared with numerical modellings of the dynamics and emission of the capillary discharge plasma, which enables the determination of plasma parameters and the future use of the codes as additional instruments for plasma diagnostics. (author)

  14. Xe isotope detection and discrimination using beta spectroscopy with coincident gamma spectroscopy

    Science.gov (United States)

    Reeder, P. L.; Bowyer, T. W.

    1998-02-01

    Beta spectroscopic techniques show promise of significant improvements for a beta-gamma coincidence counter that is part of a system for analyzing Xe automatically separated from air. The previously developed counting system for 131mXe, 133mXe, 133gXe, and 135gXe can be enhanced to give additional discrimination between these Xe isotopes by using the plastic scintillation sample cell as a beta spectrometer to resolve the conversion electron peaks. The automated system will be a key factor in monitoring the Comprehensive Test Ban Treaty.

  15. Xe isotopic abundances in enstatite meteorites and relations to other planetary reservoirs

    International Nuclear Information System (INIS)

    Lee, Jee-Yon; Marti, Kurt; Wacker, John F.

    2009-01-01

    This paper describes the interpretation of xenon that was measured in the Abee meteorite. Reported Xe isotopic abundances in enstatite chondrites (EC's) show some variability, and this makes comparisons to other solar system reservoirs rather difficult. In contrast, we find uniform Xe isotopic abundances in the EC chondrite Abee for a variety of clasts, except for 128 Xe and 129 Xe, the isotopes affected by neutron capture in I and by extinct 129 I. We report averages for the studied clasts which are consistent within error limits with OC-Xe and with the Q-Xe signature. On the other hand, the elemental abundance ratios Ar/Xe are variable between clasts. A strongly reducing environment which is indicated for enstatite meteorites was generally assumed to be consistent with conditions existing in the early inner solar system. Xe isotopic abundances in SNC meteorites from Mars and also those in some terrestrial wells show that distinct isotopic reservoirs coexisted on the same planets. In particular, the Xe isotopic signatures in terrestrial well gases show the presence of a minor distinct component in two of the reported four well gases. These authors suggested that the extra component represents solar Xe, but we show that also a meteoritic xenon reservoir of the Abee-Xe structure is an option. The reported Xe data in Ar-rich (subsolar) EC's show isotopic abundances slightly lighter than those in Abee-Xe, but the relative abundances of Ar, Kr, and Xe indicate only a minor component of elementally unfractionated solar Xe. The elemental ratios suggest rather a different origin for these gases: the loading of solar particles into grain surfaces during exposure at elevated temperatures during accretion of matter in the inner solar system. A model of this type was suggested for the accretion of gases now observed in the atmosphere on Venus. We note that disks of crystalline silicates (including enstatite and olivine) have been observed in T Tauri stars during their early

  16. High explosive programmed burn in the FLAG code

    Energy Technology Data Exchange (ETDEWEB)

    Mandell, D.; Burton, D.; Lund, C.

    1998-02-01

    The models used to calculate the programmed burn high-explosive lighting times for two- and three-dimensions in the FLAG code are described. FLAG uses an unstructured polyhedra grid. The calculations were compared to exact solutions for a square in two dimensions and for a cube in three dimensions. The maximum error was 3.95 percent in two dimensions and 4.84 percent in three dimensions. The high explosive lighting time model described has the advantage that only one cell at a time needs to be considered.

  17. Performance evaluation of the microINR® point-of-care INR-testing system.

    Science.gov (United States)

    Joubert, J; van Zyl, M C; Raubenheimer, J

    2018-04-01

    Point-of-care International Normalised Ratio (INR) testing is used frequently. We evaluated the microINR ® POC system for accuracy, precision and measurement repeatability, and investigated instrument and test chip variability and error rates. Venous blood INRs of 210 patients on warfarin were obtained with Thromborel ® S on the Sysmex CS-2100i ® analyser and compared with capillary blood microINR ® values. Precision was assessed using control materials. Measurement repeatability was calculated on 51 duplicate finger-prick INRs. Triplicate finger-prick INRs using three different instruments (30 patients) and three different test chip lots (29 patients) were used to evaluate instrument and test chip variability. Linear regression analysis of microINR ® and Sysmex CS2100i ® values showed a correlation coefficient of 0.96 (P < .0001) and a positive proportional bias of 4.4%. Dosage concordance was 93.8% and clinical agreement 95.7%. All acceptance criteria based on ISO standard 17593:2007 system accuracy requirements were met. Control material coefficients of variation (CV) varied from 6.2% to 16.7%. The capillary blood measurement repeatability CV was 7.5%. No significant instrument (P = .93) or test chip (P = .81) variability was found, and the error rate was low (2.8%). The microINR ® instrument is accurate and precise for monitoring warfarin therapy. © 2017 John Wiley & Sons Ltd.

  18. 76 FR 39885 - Risk-Based Targeting of Foreign Flagged Mobile Offshore Drilling Units (MODUs)

    Science.gov (United States)

    2011-07-07

    ... Foreign Flagged Mobile Offshore Drilling Units (MODUs) AGENCY: Coast Guard, DHS. ACTION: Notice of... 11-06, Risk-Based Targeting of Foreign Flagged Mobile Offshore Drilling Units (MODUs). This policy... applicable regulations, every foreign-flagged mobile offshore drilling unit (MODU) must undergo a Coast Guard...

  19. Artist's rendering of astronaut Neil Armstrong planting U.S. flag on Moon

    Science.gov (United States)

    1969-01-01

    Artist's Concept: Apollo 11 astronaut Neil Armstrong, after stepping onto the lunar surface, will plant the United States flag in its soil. The flag will be made of nylone, size 3- by 5 feet on a staff 8 feet long. During flight it will be stowed in two 4-foot sections strapped to the Lunar Module ladder. Armstrong's first assignment after stepping off the ladder is to pull a 'D' ring to start a television camera. The second assignment is to erect the U.S. flag. The flag will appear to be flying in a breeze. This is done with a spring-loaded wire in the nylon cloth. With everything is working normally, this will be observed on live television.

  20. XeCl Excimer Laser with Three- and Four-Component Mixture of Active Gases

    International Nuclear Information System (INIS)

    Iwanejko, L.; Pokora, L.

    1998-01-01

    Selected results of investigations of a XeCl excimer laser employing a new type (four-component)of mixture of gases, He-Kr:Xe-HCl, are presented. The mixture includes, instead of Xe, a mixture of not-separated Kr and Xe gases, much less expensive than pure xenon. A comparison of durations and energies of pulses generated in the XeCl excimer laser using three- or four-component gaseous active medium (He-Xe-HCl or He-Kr:Xe-HCl) is made. The investigations have been carried out with the use of a laser system with UV preionization and self sustained pumping discharge. (author)

  1. Variable energy positron beam study of Xe-implanted uranium oxide

    International Nuclear Information System (INIS)

    Djourelov, Nikolay; Marchand, Benoît; Marinov, Hristo; Moncoffre, Nathalie; Pipon, Yves; Nédélec, Patrick; Toulhoat, Nelly; Sillou, Daniel

    2013-01-01

    Doppler broadening of annihilation gamma-line combined with a slow positron beam was used to measure the momentum density distribution of annihilating pair in a set of sintered UO 2 samples. The influence of surface polishing, of implantation with 800-keV 136 Xe 2+ at fluences of 1 × 10 15 and 1 × 10 16 Xe cm −2 , and of annealing were studied by following the changes of the momentum distribution shape by means of S and W parameters. The program used for this purpose was VEPFIT. At the two fluences in the stoichiometric as-implanted UO 2 , formation of Xe bubbles was not detected. The post-implantation annealing and over-stoichiometry in the as-implanted sample caused Xe precipitation and formation of Xe bubbles.

  2. Evaluation of reactivity and Xe behavior during daily load following operation

    International Nuclear Information System (INIS)

    Sakamoto, Yasunori; Araki, Tsuneyasu; Yamamoto, Fumiaki

    1992-01-01

    A boiling water reactor (BWR) has an excellent load following capability provided by a core flow control, which is used for changing a reactor power level and for compensating the subsequent Xe concentration change. The core characteristics during load following operations are investigated in detail, using our reactor core simulator. Comparisons of changes of the Doppler reactivity, the void reactivity and the Xe reactivity during transients are performed. Also the features of Xe transient during load following operations are shown. It has been shown that the core flow change required to compensate the Xe reactivity change produces much greater change of the void reactivity than that required for power level changes, and that the resulting local power change in the lower part of the core is greater than that in the upper part, because the Xe concentration change in the lower part is hardly compensated by the core flow control. Also the effects of power level changes, cycle patterns, and initial concentration of Xe and I on the Xe transient behavior have been investigated. (author)

  3. Pseudo-Kaehler quantization on flag manifolds

    International Nuclear Information System (INIS)

    Karabegov, A.V.

    1997-07-01

    A unified approach to geometric, symbol and deformation quantizations on a generalized flag manifold endowed with an invariant pseudo-Kaehler structure is proposed. In particular cases we arrive at Berezin's quantization via covariant and contravariant symbols. (author). 16 refs

  4. I-Xe dating of silicate and troilite from IAB iron meteorites

    International Nuclear Information System (INIS)

    Niemeyer, S.

    1978-01-01

    The IAB iron meteorites may be related to the chondrites; siderophile elements in the metal matrix have chondritic abundances, and the abundant silicate inclusions are chondritic both in mineralogy and in chemical composition. Silicate and troilite (FeS) and IAB irons were analyzed by the I-Xe technique. Four IAB silicate samples gave well-defined I-Xe ages [in millions of years relative to Bjurboele; the monitor error (+-2.5 m.y.) is not included]: -3.7 +- 0.3 for Woodbine, -0.7 +- 0.6 for Mundrabilla, +1.4 +- 0.7 for Copiapo, and +2.6 +- 0.6 for Landes. The ( 129 Xe/ 132 Xe)/sub trapped/ ratios are consistent with previous values for chondrites, with the exception of Landes which has an extraordinary trapped ratio of 3.5 +- 0.2. Both analyses of silicate from Pitts gave anomalous I-Xe patterns: intermediate-temperature points defined good correlations but higher-temperature (greater than or equal to 1400 0 C) points lay above (extra 129 Xe) these lines. The two correlations have different slopes, so it cannot be assigned a definite I-Xe age to Pitts silicate. Troilite samples from Mundrabilla and Pitts were also analyzed: Pitts troilite gave a complex I-Xe pattern, which suggests an age of +17 m.y.; Mundrabilla troilite defined a good I-Xe correlation, which after correction for neutron capture on 128 Te an age of -10.8 +- 0.7 m.y. Thus, surprisingly, low-melting troilite substantially predates high-melting silicate in Mundrabilla. Abundances of Ga, Ge, and Ni in metal from these meteorites are correlated with I-Xe ages of the silicate (referred to henceforth as the metal-silicate correlation). After exploring possible relationships between the I-Xe ages and other properties of the IAB group, it was concluded that the metal-silicate correlation, the old Mundrabilla troilite, and other results favor a nebular formation model (e.g. Wasson, 1970a)

  5. Xe/Kr Selectivity Measurements using AgZ-PAN at Various Temperatures

    International Nuclear Information System (INIS)

    Garn, Troy Gerry; Greenhalgh, Mitchell Randy; Watson, Tony Leroy

    2015-01-01

    In preparation for planned FY-15 Xe/Kr multi-column testing, a series of experiments were performed to determine the selectivity of Xe over Kr using the silver converted mordenite-polyacrylonitrile (AgZ-PAN) sorbent. Results from these experiments will be used for parameter selection guidelines to define test conditions for Kr gas capture purity evaluations later this year. The currently configured experimental test bed was modified by installing a new cooling apparatus to permit future multi-column testing with independent column temperature control. The modified test bed will allow for multi-column testing to facilitate a Xe separation followed by a Kr separation using engineered form sorbents. Selectivity experiments were run at temperatures of 295, 250 and 220 K. Two feed gas compositions of 1000 ppmv Xe, 150 ppmv Kr in either a He or an air balance were used. AgZ-PAN sorbent selectivity was calculated using Xe and Kr capacity determinations. AgZ-PAN sorbent selectivities for Xe over Kr of 72 were calculated at room temperature (295 K) using the feed gas with a He balance and 34 using the feed gas with an air balance. As the test temperatures were decreased the selectivity of Xe over Kr also decreased due to an increase in both Xe and Kr capacities. At 220 K, the sorbent selectivities for Xe over Kr were 22 using the feed gas with a He balance and 28 using the feed gas with an air balance. The selectivity results indicate that AgZ-PAN used in the first column of a multi-column configuration will provide adequate partitioning of Xe from Kr in the tested temperature range to produce a more pure Kr end product for collection.

  6. Effect of Xe ion (167 MeV) irradiation on polycrystalline SiC implanted with Kr and Xe at room temperature

    International Nuclear Information System (INIS)

    Hlatshwayo, T T; Kuhudzai, R J; Njoroge, E G; Malherbe, J B; O’Connell, J H; Skuratov, V A; Msimanga, M

    2015-01-01

    The effect of swift heavy ion (Xe 167 MeV) irradiation on polycrystalline SiC individually implanted with 360 keV Kr and Xe ions at room temperature to fluences of 2  ×  10 16 cm −2 and 1  ×  10 16 cm −2 respectively, was investigated using transmission electron microscopy (TEM), Raman spectroscopy and Rutherford backscattering spectrometry (RBS). Implanted specimens were each irradiated with 167 MeV Xe +26 ions to a fluence of 8.3  ×  10 14 cm −2 at room temperature. It was observed that implantation of 360 keV Kr and Xe ions individually at room temperature amorphized the SiC from the surface up to a depth of 186 and 219 nm respectively. Swift heavy ion (SHI) irradiation reduced the amorphous layer by about 27 nm and 30 nm for the Kr and Xe samples respectively. Interestingly, the reduction in the amorphous layer was accompanied by the appearance of randomly oriented nanocrystals in the former amorphous layers after SHI irradiation in both samples. Previously, no similar nanocrystals were observed after SHI irradiations at electron stopping powers of 33 keV nm −1 and 20 keV nm −1 to fluences below 10 14 cm −2 . Therefore, our results suggest a fluence threshold for the formation of nanocrystals in the initial amorphous SiC after SHI irradiation. Raman results also indicated some annealing of radiation damage after swift heavy ion irradiation and the subsequent formation of small SiC crystals in the amorphous layers. No diffusion of implanted Kr and Xe was observed after swift heavy ion irradiation. (paper)

  7. Shock disturbance of the I-Xe system

    International Nuclear Information System (INIS)

    Caffee, M.W.; Hohenberg, C.M.; Podosek, F.A.; Swindle, T.D.

    1982-01-01

    Three separate samples of the meteorite Bjurbole were artificially shocked at pressures of 70 kb, 200 kb, and 400 kb. Analysis of xenon released in stepwise heating shows that the I-Xe system of the 400 kb sample is substantially altered by the shock loading, and it is no longer possible to infer an age or trapped xenon composition for that sample. The 200-kb and 70-kb samples display isotopic structures progressively less altered demonstrating the gradations in shock disturbance likely to be found in natural systems. Interpretations of the I-Xe and Ar-40-Ar-39 systems for several naturally shocked meteorites are also presented. New data for Arapahoe do not confirm the previously reported age and trapped xenon composition, demonstrating instead that its I-Xe structure has been strongly disturbed by shock

  8. The iconography of the flags of Charles V: examples and documents

    Directory of Open Access Journals (Sweden)

    Jesús F. Pascual Molina

    2017-03-01

    Full Text Available The Emperor Charles V formed an important group of arms and armor in his armory at Valladolid. In 1556, during his last journey to Spain, new pieces were sent to this royal armory; after his death they passed to Philip II, who sent them to Madrid, where he ordered a new building especially for the collection. Among these pieces was an important group of flags linked to major episodes of the Emperor’s life. The author describes the flags and their iconography, providing as well unpublished archival materials, which permit a better understanding of the flags used in times of Caesar Charles and their meanings.

  9. Calculation of Ion Charge State Distributions After Inner-Shell Ionization in Xe Atom

    International Nuclear Information System (INIS)

    Mohammedein, A.M.; Ghoneim, A.A.; Kandil, M.K.; Kadad, I.M.

    2009-01-01

    The vacancy cascades following initial inner-shell vacancies in single and multi-ionized atoms often lead to highly charged residual ions. The inner-shell vacancy produced by ionization processes may decay by either a radiative or non-radiative transition. In addition to the vacancy filling processes, there is an electron shake off process due to the change of core potential of the atom. In the calculation of vacancy cascades, the radiative (x-ray) and non-radiative (Auger and Coster-Kronig) branching ratios give valuable information on the de-excitation dynamics of an atom with inner-shell vacancy. The production of multi-charged ions yield by the Auger cascades following inner shell ionization of an atom has been studied both experimentally and theoretically. Multi-charged Xe ions following de-excitation of K, L 1 , L 2,3 , M 1 , M 2,3 and M 4,5 subshell vacancies are calculated using Monte-Carlo algorithm to simulate the vacancy cascade development. Fluorescence yield (radiative) and Auger, Coster- Kronig yield (non- radiative) are evaluated. The decay of K hole state through radiative transitions is found to be more probable than non-radiative transitions in the first step of de-excitation. On the other hand, the decay of L, M vacancies through non-radiative transitions are more probable. The K shell ionization in Xe atom mainly yields Xe 7+ , Xe 8+ , Xe 9+ and Xe 1 0 + ions, and the charged X 8+ ions are the highest. The main product from the L 1 shell ionization is found to be Xe 8+ , Xe 9+ ions, while the charged Xe 8+ ions predominate at L 2,3 hole states. The charged Xe 6+ , Xe 7+ and Xe 8+ ions mainly yield from 3s 1/2 and 3p 1/2 , 3/2 ionization, while Xe in 3d 3/2 , 5/2 hole states mainly turns into Xe 4+ and Xe 5+ ions. The present results are found to agree well with the experimental data. (author)

  10. Cyber Flag: A Realistic Cyberspace Training Construct

    National Research Council Canada - National Science Library

    Hansen, Andrew P

    2008-01-01

    .... Red Flag provides dominant training within the air domain and now with the evolution of cyberspace, a comprehensive training environment is necessary to meet this growing and broadening threat...

  11. In-situ observation of atomic self-organization processes in Xe nanocrystals embedded in Al

    International Nuclear Information System (INIS)

    Mitsuishi, K.; Song, M.; Furuya, K.; Birtcher, R. C.; Allen, C. W.; Donnelly, S. E.

    1998-01-01

    Self-organization processes in Xe nanocrystals embedded in Al are observed with in-situ high-resolution electron microscopy. Under electron irradiation, stacking fault type defects are produced in Xe nanocrystals. The defects recover in a layer by layer manner. Detailed analysis of the video reveals that the displacement of Xe atoms in the stacking fault was rather small for the Xe atoms at boundary between Xe and Al, suggesting the possibility of the stacking fault in Xe precipitate originating inside of precipitate, not at the Al/Xe interface

  12. Excess 129Xe in terrestrial samples: A non-primordial hypothesis

    International Nuclear Information System (INIS)

    Caffee, M.W.; Hudson, G.B.

    1987-03-01

    Excesses of 129 Xe relative to the isotopic composition in air are observed in some terrestrial samples. Traditionally these 129 Xe excesses have been thought to be related to 129 I that was present in abundance in the early solar system. We propose an alternative hypothesis to explain terrestrial 129 Xe excesses based on the production of 129 I from the spontaneous fission of 238 U

  13. FlagHouse Forum: You Say "Tomato"... and I Use a Communicator

    Science.gov (United States)

    Exceptional Parent, 2011

    2011-01-01

    This month's "FlagHouse Forum" focuses on how to choose the communicator best-suited to a child's special need. FlagHouse--a premier global supplier of resources for special needs, education, physical activity and recreation--is pleased to partner with "Exceptional Parent" to bring its readers this informational forum. Humans communicate with each…

  14. HEMATOPOIETIC PROGENITOR CELLS AS A PREDICTIVE OF CD34+ ENUMERATION PRIOR TO PERIPHERAL BLOOD STEM CELLS HARVESTING

    Directory of Open Access Journals (Sweden)

    Z. Zulkafli

    2014-09-01

    Full Text Available Background: To date, the CD34+ cell enumeration has relied predominantly on flow cytometry technique. However, flow cytometry is time consuming and operator dependent. The application of the hematopoietic progenitor cells (HPCs channel in Sysmex XE-2100, a fully automated hematology analyzer offers an alternative approach, which is with minimal sample manipulation and less operator dependent. This study evaluates the utility of HPC counts as a predictive of CD34+ enumeration prior to peripheral blood stem cells harvesting. Materials and methods: HPC, CD34+, white blood cell (WBC, reticulocytes (retic, immature platelet fraction (IPF and immature reticulocyte fraction (IRF were determined in 61 samples from 19 patients with hematological malignancies (15 lymphoma and 4 multiple myeloma patients at Hospital Universiti Sains Malaysia (Hospital USM who had received granulocyte-colony stimulating factor (G-CSF and planned for autologous transplantation. Results: CD34+ count showed strong and significant correlation with HPC. The receiver operating characteristics (ROC curve analysis revealed that HPC count > 21.5 x 106 / L can predicts a pre harvest CD34+ count of >20 x 106 / L with sensitivity of 77%, specificity of 64% and area under the curve (AUC of 0.802. Conclusion: We concluded that HPC count can be a useful potential parameter in optimizing timing for CD34+ enumeration prior to leukapheresis.

  15. Anomalous Hydrodynamic Drafting of Interacting Flapping Flags

    Science.gov (United States)

    Ristroph, Leif; Zhang, Jun

    2008-11-01

    In aggregates of objects moving through a fluid, bodies downstream of a leader generally experience reduced drag force. This conventional drafting holds for objects of fixed shape, but interactions of deformable bodies in a flow are poorly understood, as in schools of fish. In our experiments on “schooling” flapping flags, we find that it is the leader of a group who enjoys a significant drag reduction (of up to 50%), while the downstream flag suffers a drag increase. This counterintuitive inverted drag relationship is rationalized by dissecting the mutual influence of shape and flow in determining drag. Inverted drafting has never been observed with rigid bodies, apparently due to the inability to deform in response to the altered flow field of neighbors.

  16. Luminescent Characteristics of a Pulsed Discharge Plasma in Xe-KBr Mixture

    Science.gov (United States)

    Heneral, A. A.; Zhmenyak, Y. V.

    2018-03-01

    A mixture of xenon with a nontoxic halogen carrier Xe-KBr is used to create a plasma radiation source at the 282-nm transition of the XeBr* molecule excited by a high-voltage pulsed-periodic discharge. The luminescence spectra of the plasma of a longitudinal pulsed-periodic discharge in the Xe-KBr mixture at low pressures are studied experimentally. The most intense UV bands of exciplex XeBr* molecules are recorded in the spectral range of 250-350 nm. The spectral, temporal, and energetic characteristics of the radiation source are presented, as well as the dependence of the XeBr* exciplex molecule formation efficiency on the discharge excitation conditions. The optimal conditions for the excitation of UV radiation in the pulsed-periodic discharge plasma are determined.

  17. Xe isotopic constraints on cycling of deep Earth volatiles

    Science.gov (United States)

    Parai, R.; Mukhopadhyay, S.

    2017-12-01

    The modern deep Earth volatile budget reflects primordial volatiles delivered during accretion, radiogenic ingrowth of volatile species (e.g., 40Ar produced by 40K decay), outgassing in association with mantle processing, and regassing via subduction. The noble gases are unique volatile tracers in that they are chemically inert, but are thought to be trapped within hydrous alteration phases in downwelling lithologies. Noble gases thus provide a tracer of volatile transport between the deep Earth and surface reservoirs. Constraints on the fluxes of noble gases between deep Earth and surface reservoirs over time can accordingly be used to provide insight into temperature conditions at subduction zones, limits on volatile cycling, and the evolving distribution of major volatile species in terrestrial reservoirs over time. Xe isotope systematics in mantle-derived rocks show that 80-90% of the mantle Xe budget is derived from recycling of atmospheric Xe, indicating that atmospheric Xe is retained in subducting slabs beyond depths of magma generation in subduction zones over Earth history. We present an integrated model of Xe cycling between the mantle and atmosphere in association with mantle processing over Earth history. We test a wide variety of outgassing and regassing rates and take the evolution of the atmospheric Xe isotopic composition [e.g., 1] into account. Models in which the deep Earth transitions from a net outgassing to net regassing regime best satisfy Xe isotopic constraints from mantle-derived rocks [2-6]. [1] Avice et al., 2017; Nature Communications, 8; [2] Mukhopadhyay, 2012, Nature 486, 101-104; [3] Parai et al., 2012, EPSL 359-360, 227-239; [4] Parai and Mukhopadhay, 2015, G-cubed 16, 719-735; [5] Peto et al., 2013, EPSL 369-370, 13-23; [6] Tucker et al., 2012, EPSL 355-356, 244-254.

  18. Closing in on parton energy loss with charged particle spectra in Xe-Xe and Pb-Pb collisions with ALICE

    CERN Multimedia

    CERN. Geneva

    2018-01-01

    For comparison, a pp reference at the collision energy of 5.44 TeV is obtained by interpolating between existing pp measurements at 5.02 and 7 TeV.  The nuclear modification factor in Xe-Xe collisions is compared to Pb-Pb collisions at 5.02 TeV and 2.76 TeV, showing remarkable similarity at pT > 10 GeV/c. The comparison of the measured nuclear mod...

  19. Modulation of ERG channels by XE991

    DEFF Research Database (Denmark)

    Elmedyb, Pernille; Calloe, Kirstine; Schmitt, Nicole

    2007-01-01

    In neuronal tissue, KCNQ2-5 channels conduct the physiologically important M-current. In some neurones, the M-current may in addition be conducted partly by ERG potassium channels, which have widely overlapping expression with the KCNQ channel subunits. XE991 and linopiridine are known to be stan......In neuronal tissue, KCNQ2-5 channels conduct the physiologically important M-current. In some neurones, the M-current may in addition be conducted partly by ERG potassium channels, which have widely overlapping expression with the KCNQ channel subunits. XE991 and linopiridine are known...... to be standard KCNQ potassium channel blockers. These compounds have been used in many different tissues as specific pharmacological tools to discern native currents conducted by KCNQ channels from other potassium currents. In this article, we demonstrate that ERG1-2 channels are also reversibly inhibited by XE......991 in the micromolar range (EC(50) 107 microM for ERG1). The effect has been characterized in Xenopus laevis oocytes expressing ERG1-2 and in the mammalian HEK293 cell line stably expressing ERG1 channels. The IC(50) values for block of KCNQ channels by XE991 range 1-65 microM. In conclusion, great...

  20. Stellar laboratories . VIII. New Zr iv-vii, Xe iv-v, and Xe vii oscillator strengths and the Al, Zr, and Xe abundances in the hot white dwarfs G191-B2B and RE 0503-289

    Science.gov (United States)

    Rauch, T.; Gamrath, S.; Quinet, P.; Löbling, L.; Hoyer, D.; Werner, K.; Kruk, J. W.; Demleitner, M.

    2017-03-01

    Context. For the spectral analysis of high-resolution and high-signal-to-noise spectra of hot stars, state-of-the-art non-local thermodynamic equilibrium (NLTE) model atmospheres are mandatory. These are strongly dependent on the reliability of the atomic data that is used for their calculation. Aims: To search for zirconium and xenon lines in the ultraviolet (UV) spectra of G191-B2B and RE 0503-289, new Zr iv-vii, Xe iv-v, and Xe vii oscillator strengths were calculated. This allows, for the first time, determination of the Zr abundance in white dwarf (WD) stars and improvement of the Xe abundance determinations. Methods: We calculated Zr iv-vii, Xe iv-v, and Xe vii oscillator strengths to consider radiative and collisional bound-bound transitions of Zr and Xe in our NLTE stellar-atmosphere models for the analysis of their lines exhibited in UV observations of the hot WDs G191-B2B and RE 0503-289. Results: We identified one new Zr iv, 14 new Zr v, and ten new Zr vi lines in the spectrum of RE 0503-289. Zr was detected for the first time in a WD. We measured a Zr abundance of -3.5 ± 0.2 (logarithmic mass fraction, approx. 11 500 times solar). We identified five new Xe vi lines and determined a Xe abundance of -3.9 ± 0.2 (approx. 7500 times solar). We determined a preliminary photospheric Al abundance of -4.3 ± 0.2 (solar) in RE 0503-289. In the spectra of G191-B2B, no Zr line was identified. The strongest Zr iv line (1598.948 Å) in our model gave an upper limit of -5.6 ± 0.3 (approx. 100 times solar). No Xe line was identified in the UV spectrum of G191-B2B and we confirmed the previously determined upper limit of -6.8 ± 0.3 (ten times solar). Conclusions: Precise measurements and calculations of atomic data are a prerequisite for advanced NLTE stellar-atmosphere modeling. Observed Zr iv-vi and Xe vi-vii line profiles in the UV spectrum of RE 0503-289 were simultaneously well reproduced with our newly calculated oscillator strengths. Based on observations

  1. 46 CFR 252.22 - Substantiality and extent of foreign-flag competition.

    Science.gov (United States)

    2010-10-01

    ... January 1 of the subsidized year, by surveying a data file known as “Merchant Fleets of the World” that is... total tonnage in the range. (e) Largest foreign flag not competitor. In the event that the Board... competitor of any particular operator, the Board may determine the foreign-flag competition in a manner that...

  2. Constraints on the timing of the Moon-forming giant impact from MORB Xe isotopes

    Science.gov (United States)

    Parai, R.; Mukhopadhyay, S.

    2014-12-01

    As Earth accreted, volatiles were delivered by accreting material and lost by degassing and impact-driven ejection to space. The Moon-forming giant impact initiated the final catastrophic outgassing and bulk volatile ejection event on the early Earth. I-Pu-U-Xe systematics provide a powerful tool to probe degassing of the early Earth. Radiogenic 129Xe was produced by β-decay of the extinct nuclide 129I (t1/2 = 15.7 Ma) in the first ~90 Myr of Earth history. Fissiogenic 131Xe, 132Xe, 134Xe, 136Xe were produced in distinct, characteristic proportions by the fission of extinct short-lived 244Pu (t1/2 = 80.0 Myr) and extant long-lived 238U (t1/2 = 4.468 Gyr). Here we present radiogenic and fission Xe data in basalts from the Southwest Indian Ridge, and discuss them with other mantle-derived samples to shed light on early Earth volatile accretion and loss. Based on the ratio of radiogenic 129Xe to plutogenic 136Xe determined for the MORB source, we calculate an I-Pu-Xe closure age for the upper mantle of ~44-70 Myr after the start of the Solar System. The closure age should correspond to the end of catastrophic mantle outgassing during accretion, and thus constrains the age of the last giant impact (LGI). Our closure age is significantly older than previous Xe closure age determinations of ~100 Myr, and is also older than some direct radiometric ages of lunar crustal samples. In order to explore the effects of accretion timescales, partial early retention of Xe, and degassing associated with long-term mantle processing on Xe closure age, we develop a new model of I-Pu-U-Xe systematics. We find that for LGI's between ~35 and 70 Myr after the start of the Solar System, we are able to satisfy constraints on I-Pu-U-Xe systematics simultaneously without invoking partial retention of Xe prior to the last giant impact. For LGI's after ~80 Myr, partial retention of Xe prior to the LGI is required. Non-zero early retention of Xe is necessary to explain the budgets of primordial

  3. Echo-planar MR imaging of dissolved hyperpolarized 129Xe. Potential for M angiography

    International Nuclear Information System (INIS)

    Maansson, S.

    2002-01-01

    Purpose: The feasibility of hyperpolarized 129 Xe for fast MR angiography (MRA) was evaluated using the echo-planar imaging (EPI) technique. Material and Methods: Hyperpolarized Xe gas was dissolved in ethanol; a carrier agent with high solubility for Xe (Ostwald solubility coefficient 2.5) and long relaxation times. The dissolved Xe was injected as a bolus into a flow phantom where the mean flow velocity was 15 cm/s. Ultrafast EPI images with 44 ms scan time were acquired of the flowing bolus and the signal-to-noise ratios (SNR) were measured. Results: The relaxation times of hyperpolarized Xe in ethanol were measured to T1=160±11 s and T2 ≅ 20 s. The resulting images of the flowing liquid were of reasonable quality and had an SNR of about 70. Conclusion: Based on the SNR of the obtained Xe EPI images; it was estimated that rapid in vivo MRA with 129 Xe may be feasible; provided that an efficient; biologically acceptable carrier for Xe can be found and polarization levels of more than 25% can be achieved in isotopically enriched 129 Xe

  4. Yellow flag scores in a compensable New Zealand cohort suffering acute low back pain

    Directory of Open Access Journals (Sweden)

    Karen Grimmer-Somers

    2008-12-01

    Full Text Available Karen Grimmer-Somers1, Mathew Prior1, Jim Robertson21Centre for Allied Health Evidence, University of South Australia, City East Campus, North Tce, Adelaide, South Australia, Australia; 2New Zealand Accident Compensation Corporation, Auckland, New ZealandBackground: Despite its high prevalence, most acute low back pain (ALBP is nonspecific, self-limiting with no definable pathology. Recurrence is prevalent, as is resultant chronicity. Psychosocial factors (yellow flags comprising depression and anxiety, negative pain beliefs, job dissatisfaction are associated with the development of chronic LBP.Methods: A national insurer (Accident Compensation Corporation, New Zealand [NZ], in conjunction with a NZ primary health organization, piloted a strategy for more effective management of patients with ALBP, by following the NZ ALBP Guideline. The guidelines recommend the use of a psychosocial screening instrument (Yellow Flags Screening Instrument, a derivative of Örebro Musculoskeletal Pain Questionnaire. This instrument was recommended for administration on the second visit to a general medical practitioner (GP. This paper tests whether published cut-points of yellow flag scores to predict LBP claims length and costs were valid in this cohort.Results: Data was available for 902 claimants appropriately enrolled into the pilot. 25% claimants consulted the GP once only, and thus were not requested to provide a yellow flag score. Yellow flag scores were provided by 48% claimants who consumed two or more GP services. Approximately 60% LBP presentations resolved within five GP visits. Yellow flag scores were significantly and positively associated with treatment costs and service use, although the association was nonlinear. Claimants with moderate yellow flag scores were similarly likely to incur lengthy claims as claimants with at-risk scores.Discussion: Capturing data on psychosocial factors for compensable patients with ALBP has merit in predicting

  5. High Sensitivity Detection of Xe Isotopes Via Beta-Gamma Coincidence Counting

    International Nuclear Information System (INIS)

    Bowyer, Ted W.; McIntyre, Justin I.; Reeder, Paul L.

    1999-01-01

    Measurement of xenon fission product isotopes is a key element in the global network being established to monitor the Comprehensive Nuclear-Test-Ban Treaty. Pacific Northwest National Laboratory has developed an automated system for separating Xe from air which includes a beta-gamma counting system for 131mXe, 133mXe, 133Xe, and 135Xe. Betas and conversion electrons are detected in a plastic scintillation cell containing the Xe sample. The counting geometry is nearly 100% for beta and conversion electrons. The resolution in the pulse height spectrum from the plastic scintillator is sufficient to observe distinct peaks for specific conversion electrons. Gamma and X-rays are detected in a NaI(Tl) scintillation detector which surrounds the plastic scintillator sample cell. Two-dimensional pulse height spectra of gamma energy versus beta energy are obtained. Each of the four xenon isotopes has a distinctive signature in the two-dimensional energy array. The details of the counting system, examples of two-dimensional beta-gamma data, and operational experience with this counting system will be described

  6. Revised analysis of singly ionized xenon, Xe II

    International Nuclear Information System (INIS)

    Hansen, J.E.; Persson, W.

    1987-01-01

    We present a revised analysis of the spectrum of singly ionized xenon, Xe II. This spectrum has been reanalyzed on the basis of the wavelength material published by Drs J. C. Boyce and C. J. Humphreys. The latter has kindly placed the original wavelength list covering the wavelength range 10220-390 A at our disposal. We report 161 energy levels which have been identified on the basis of classifications of 950 lines. We report first f and g levels in Xe II. Also a number of g-factors have been determined for the first time and we give in total 75 g-factors. We have carried out least-squares fits to the even configurations and report the resulting parameter values and eigenvector compositions. A least-squares fit to the 5p 4 6p configuration is also reported. The levels have been named in jK and for many levels also in LS coupling. The former is the better coupling scheme for Xe II. We present an analysis of the 5s photoelectron satellite spectrum of Xe based on our calculated eigenvector compositions and calculations of transition probabilities for ground state transitions as well as lifetimes for the 6p levels. The latter are compared to recent experimental measurements. A list of wavelengths for observed laser transitions showing the present classifications and a discussion of the determination of the ionization potential of Xe II concludes the paper. (orig.)

  7. Saturated multikilovolt x-ray amplification with Xe clusters: single-pulse observation of Xe(L) spectral hole burning

    International Nuclear Information System (INIS)

    Borisov, Alex B; Davis, Jack; Song, Xiangyang; Koshman, Yevgeniya; Dai Yang; Boyer, Keith; Rhodes, Charles K

    2003-01-01

    Single-pulse measurements of spectral hole burning of Xe(L) 3d → 2p hollow atom transition arrays observed from a self-trapped plasma channel provide new information on the dynamics of saturated amplification in the λ ∼ 2.8-2.9 A region. The spectral hole burning on transitions in the Xe 34+ and Xe 35+ arrays reaches full suppression of the spontaneous emission and presents a corresponding width Δ h-bar ω x ∼ = 60 eV, a value adequate for efficient amplification of multikilovolt x-ray pulses down to a limiting length τ x ∼ 30 as. The depth of the suppression at 2.86 A indicates that the gain-to-loss ratio is ≥10. An independent determination of the x-ray pulse energy from damage produced on the surface of a Ti foil in the far field of the source gives a pulse energy of 20-30 μJ, a range that correlates well with the observation of the spectral hole burning and indicates an overall extraction efficiency of ∼10%. (letter to the editor)

  8. Effects of Cd2+ on chlorophyll content in flag and grain yield of wheats

    International Nuclear Information System (INIS)

    Zhu Zhiyong; Li Youjun; Liu Yingjie; Duan Youqiang; Li Qiang; Hao Yufen; Guo Jia

    2011-01-01

    A field experiment was conducted with wheat cultivars Luohan 6 and Yumai 18 to investigate the effects of Cd 2+ stress on chlorophyll contents in flag leaves, flag leave area, thousand kernel weight, kernel filling velocity and yield of wheat. Results indicated that, under low Cd 2+ stress (10 mg/kg), the average contents of chlorophyll a + b of Luohan 6 reduced by 1.6%, however, its average area of flag leave and yield increased by 3.8% and 1.6%, respectively. At the same time, the average content of chlorophyll a + b, area of flag leave yield of Yumai 18 reduced 8.0%, 9.6% and 5.4%. Under high Cd 2+ stress (100 mg/kg), the average contents of chlorophyll a + b, areas of flag leaves and yields of Luohan 6 and Yumai 18 reduced by 29.2% and 30.5%, 6.3% and 17.4%, 16.7% and 36.7%, respectively. The results demonstrated that Cd 2+ restrained synthesis and accumulation of chlorophyll and its components. This study even showed that within a range of Cd 2+ concentration could promote the growth of flag leaves, and it also had an equal positive effect on yield of wheat if the Cd 2+ concentration in grains were not out of limit. The growth of flag leave and yield of wheat would be limited when Cd 2+ concentration exceed that range. Overall, Yumai 18 bore more poison from Cd 2+ than Luohan 6. (authors)

  9. Discharge efficiency in high-Xe-content plasma display panels

    NARCIS (Netherlands)

    Hayashi, D.; Kroesen, G.M.W.; Hagelaar, G.J.M.; Heusler, G.

    2004-01-01

    We study theoretically the overall output performance and the dominating reaction processes of the vacuum ultraviolet (UV) radiation production in high-Xe partial pressures in plasma display panels (PDPs) with Ne-Xe gas mixtures. A two-dimensional self-consistent fluid model is applied for the

  10. GENIE Production Release 2.10.0

    Energy Technology Data Exchange (ETDEWEB)

    Alam, M. [Aligarh Muslim Univ., Aligarh (India). Dept. of Physics; Andreopoulos, C. [Univ. of Liverpool (United Kingdom). Dept. of Physics; Science and Technology Facilities Council (STFC), Oxford (United Kingdom). Rutherford Appleton Lab. (RAL); Athar, M. [Aligarh Muslim Univ., Aligarh (India). Dept. of Physics; Bodek, A. [Univ. of Rochester, NY (United States). Dept. of Physics; Christy, E. [Hampton Univ., Hampton, VA (United States). Dept. of Physics; Coopersmith, B. [Univ. of Rochester, NY (United States). Dept. of Physics; Dennis, S. [Univ. of Warwick, Coventry (United Kingdom). Dept .of Physics; Dytman, S. [Univ. of Pittsburgh, PA (United States). Dept. of Physics and Astronomy; Gallagher, H. [Tufts Univ., Medford, MA (United States). Dept. of Physics and Astronomy; Geary, N. [Univ. of Pittsburgh, PA (United States). Dept. of Physics and Astronomy; Golan, T. [Univ. of Rochester, NY (United States). Dept. of Physics; Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Hatcher, R. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Hoshina, K. [Univ. of Wisconsin, Madison, WI (United States). Dept. of Physics. Wisconsin IceCube Particle Astrophysics Center; Liu, J. [College of William and Mary, Williamsburg, VA (United States). Dept. of Physics; Mahn, K. [Michigan State Univ., East Lansing, MI (United States). Dept. of Physics and Astronomy; Marshall, C. [Univ. of Rochester, NY (United States). Dept. of Physics; Morrison, J. [Michigan State Univ., East Lansing, MI (United States). Dept. of Physics and Astronomy; Nirkko, M. [Univ. of Bern (Switzerland). Albert Einstein Center for Fundamental Physics. Lab. for High Energy Physics (LHEP); Nowak, J. [Lancaster Univ. (United Kingdom). Dept. of Physics; Perdue, G. N. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Yarba, J. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2015-12-25

    GENIE is a neutrino Monte Carlo event generator that simulates the primary interaction of a neutrino with a nuclear target, along with the subsequent propagation of the reaction products through the nuclear medium. It additionally contains libraries for fully-featured detector geometries and for managing various types of neutrino flux. This note details recent updates to GENIE, in particular, changes introduced into the newest production release, version 2.10.0.

  11. GENIE Production Release 2.10.0

    International Nuclear Information System (INIS)

    Alam, M.; Athar, M.; Hatcher, R.; Hoshina, K.; Nowak, J.; Yarba, J.

    2015-01-01

    GENIE is a neutrino Monte Carlo event generator that simulates the primary interaction of a neutrino with a nuclear target, along with the subsequent propagation of the reaction products through the nuclear medium. It additionally contains libraries for fully-featured detector geometries and for managing various types of neutrino flux. This note details recent updates to GENIE, in particular, changes introduced into the newest production release, version 2.10.0.

  12. Modeling of Kr-Xe discharge of excimer lamp

    Directory of Open Access Journals (Sweden)

    Belasri A.

    2013-03-01

    Full Text Available This paper reports the numerical simulation of Dielectric Barrier Discharge (DBD for Kr-Xe excilamp. The model of the discharge consists of three main modules: a plasma chemistry module, a circuit module and a Boltzmann equation module. The results predict the optimal operating conditions and describe the electrical and chemical properties of the KrXe* excimer lamp.

  13. Nuclear structure studies in highly neutron-deficient (114,116)Xe

    Science.gov (United States)

    Degraaf, James Hendrick

    Lifetimes of nuclear states in 114Xe and 116Xe were measured for the first time; these nuclei represent the most neutron-deficient isotopes of xenon for which lifetimes have now been measured. The fusion-evaporation reactions 58Ni(60Ni, 2p)116Xe at 223 MeV beam energy and 58Ni(58Ni, 2p)114Xe at 215 MeV beam energy were used. Lifetimes were measured using the Recoil Distance Method (RDM) with the 8π gamma-ray spectrometer at Chalk River Laboratories. The new measurements of the B(E2;2+/to 0+) strength in these nuclei, coupled with the recent measurements for heavier xenon isotopes, are well described within the framework of the O(6) symmetry limit of the Interacting Boson Approximation. The octupole nature of the negative parity side-band was also studied, and the lifetime measurements indicate a change from a K/approx 3 structure in heavier xenon isotopes to a K/approx 0,/ 1 structure in 114Xe.

  14. XeBr excilamp based on a non-toxic component mixture

    Energy Technology Data Exchange (ETDEWEB)

    Kelman, V A; Shpenik, Yu O; Zhmenyak, Yu V, E-mail: mironkle@rambler.ru [Institute of Electron Physics, National Academy of Sciences of Ukraine, Universitetska 21, 88017 Uzhgorod (Ukraine)

    2011-06-29

    This paper presents the results of experimental studies on obtaining UV luminescence of XeBr* molecules at the excitation of a non-toxic Xe-CsBr gas-vapour mixture by a longitudinal pulse-periodic discharge. Effective UV emission yield of the exciplex XeBr* molecules (spectral maximum at 282 nm) is observed within a wide range of excitation conditions. The spectral distribution in the UV emission under the optimal excitation conditions does not differ essentially from that in other XeBr excilamps based on toxic components. The emission of the B {yields} X band of the XeBr* molecules provides the main contribution to the total power of the discharge UV emission. The determined average power of the UV emission for the experimental discharge tube is 12 W at an efficiency of 1%. Spectral, power-related and time-dependent parameters of the laboratory excilamp are presented for a wide range of excitation parameters. A new mechanism of exciplex molecule formation at the excitation of a rare gas/alkali halide vapour mixture is discussed.

  15. XeBr excilamp based on a non-toxic component mixture

    International Nuclear Information System (INIS)

    Kelman, V A; Shpenik, Yu O; Zhmenyak, Yu V

    2011-01-01

    This paper presents the results of experimental studies on obtaining UV luminescence of XeBr* molecules at the excitation of a non-toxic Xe-CsBr gas-vapour mixture by a longitudinal pulse-periodic discharge. Effective UV emission yield of the exciplex XeBr* molecules (spectral maximum at 282 nm) is observed within a wide range of excitation conditions. The spectral distribution in the UV emission under the optimal excitation conditions does not differ essentially from that in other XeBr excilamps based on toxic components. The emission of the B → X band of the XeBr* molecules provides the main contribution to the total power of the discharge UV emission. The determined average power of the UV emission for the experimental discharge tube is 12 W at an efficiency of 1%. Spectral, power-related and time-dependent parameters of the laboratory excilamp are presented for a wide range of excitation parameters. A new mechanism of exciplex molecule formation at the excitation of a rare gas/alkali halide vapour mixture is discussed.

  16. The interaction between Xe and F in Si (1 0 0) pre-amorphised with 20 keV Xe and implanted with low energy BF{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Werner, M. [Joule Physics Laboratory, Institute of Materials Research, University of Salford, Salford M54WT (United Kingdom)]. E-mail: m.werner@pgr.salford.ac.uk; Berg, J.A. van den [Joule Physics Laboratory, Institute of Materials Research, University of Salford, Salford M54WT (United Kingdom); Armour, D.G. [Joule Physics Laboratory, Institute of Materials Research, University of Salford, Salford M54WT (United Kingdom); Carter, G. [Joule Physics Laboratory, Institute of Materials Research, University of Salford, Salford M54WT (United Kingdom); Feudel, T. [AMD Saxony LLC and Co. KG, Wilschdorfer Landstrasse, 101 D-01109 Dresden (Italy); Herden, M. [AMD Saxony LLC and Co. KG, Wilschdorfer Landstrasse, 101 D-01109 Dresden (Italy); Bersani, M. [ITC IRST, 38050 Povo, Trento (Italy); Giubertoni, D. [ITC IRST, 38050 Povo, Trento (Italy); Bailey, P. [CCLRC Daresbury Laboratory, Daresbury WA44A (United Kingdom); Noakes, T.C.Q. [CCLRC Daresbury Laboratory, Daresbury WA44A (United Kingdom)

    2004-12-15

    The pre-amorphisation of Si by Xe{sup +} ions, before source/drain and extension implants, is an attractive alternative to Ge{sup +} or Si{sup +}, as it produces sharper amorphous/crystalline interfaces. Si (1 0 0) samples pre-amorphised with 20 keV Xe{sup +} to a nominal dose of 2E14 cm{sup -2} were implanted with 1 and 3 keV BF{sub 2} {sup +} to doses of 7E14 cm{sup -2}. Samples were annealed at temperatures ranging from 600 to 1130 deg. C and investigated by medium energy ion scattering (MEIS) and secondary ion mass spectrometry (SIMS). Following annealing, it was observed that implanted Xe has interacted with F originating from the BF{sub 2} {sup +} implant. MEIS studies showed that for all annealing conditions, approximately half of the Xe accumulated at depths of 7 nm for the 1 keV and at 13 nm for the 3 keV BF{sub 2} {sup +} implant. This equates to the end of range of B and F within the amorphous Si. SIMS showed that in the pre-amorphised samples, approximately 10% of the F migrates into the bulk and is trapped at the same depth in a {approx}1:1 ratio to Xe. A small fraction of the implanted B is also trapped. The effect is interpreted in terms of the formation of a defect structure within the amorphised Si, leading to F stabilised Xe bubble or XeF compound formation.

  17. Fourier photospectroscopy of Xe-C60 through a Xe 4d resonance window: theory versus recent experiment

    International Nuclear Information System (INIS)

    Patel, Aakash B; Chakraborty, Himadri S

    2011-01-01

    The photoionization cross section of endohedral Xe-C 60 over a Xe 4d giant resonance energy region, calculated in the time-dependent local density approximation, is compared with recent measurements (Kilcoyne et al 2010 Phys. Rev. Lett. 105 213001). An analysis based on the Fourier transforms of oscillatory cross sections is performed to derive a number of inherent similarities between the prediction and the data, including a large beating-type oscillation and several others of intermediate size. Results stress the need for more accurate measurements to access the wealth of information about the geometry of the system. (fast track communication)

  18. A sensitive zinc-activated 129Xe MRI probe

    International Nuclear Information System (INIS)

    Kotera, N.; Delacour, L.; Traore, T.; Buisson, D.A.; Taran, F.; Coudert, S.; Rousseau, B.; Tassali, N.; Leonce, E.; Boutin, C.; Berthault, P.; Brotin, T.; Dutasta, J.P.

    2012-01-01

    Herein we propose the use of hyper-polarized 129 Xe nuclear magnetic resonance (NMR) spectroscopy for the sensitive detection of Zn 2+ ions. To achieve this goal, the noble gas is encapsulated in dedicated host systems bearing a ligand that chelates the Zn 2+ ions. Cryptophanes, aromatic cage molecules made of cyclotriveratrylene groups, are perfectly suited to this purpose as 1) they can easily be rendered water-soluble, 2) the noble gas has a high affinity for their cavity, 3) when xenon is encapsulated, it takes a specific NMR frequency, and 4) xenon exchange in and out of the cavity insures a continuous refreshment of the Xe-cryptophane environment in hyper-polarization. We constructed a powerful 129 Xe NMR-based sensor of Zn 2+ ions, which enables for the first time measurement of Zn 2+ concentrations as low as 100 nm. This high sensitivity was achieved thanks to a smart 129 Xe MRI sensor, where the binding of the ion to the target is accompanied by a change in NMR parameters. We have also demonstrated the importance of working with enantiopure cryptophane derivatives. (O.M.)

  19. Neutron Inelastic Scattering on 134Xe at En = 5 - 8 MeV

    Science.gov (United States)

    Kidd, Mary; Tornow, Werner; Finch, Sean; Krishichayan, Fnu; Bhike, Megha

    2017-09-01

    Neutrinoless double-beta decay (0 νββ) studies are both the best way to determine the Majorana nature of the neutrino and determine its effective mass. The two main experiments searching for 0 νββ -decay of 136Xe (Q value = 2457.8 keV) are Kamland-Zen and EXO-200. Though both experiments have enriched 136Xe targets, these targets still contain significant quantities of 134Xe. Recently, a new nuclear level was discovered in 134Xe that decays to the ground state emitting a 2485.7 keV gamma ray. The γ-ray production cross section for this branch was found to be on the order of 10 mb for incident neutron energies of 2.5-4.5 MeV. Here, we have extended the investigation of this level to higher incident neutron energies, and further explore the potential neutron-induced backgrounds on both 134Xe and 136Xe for extended neutron energies. We will report our preliminary results for neutron inelastic scattering on 134Xe in applications to 0 νββ decay searches. NSF PHY-1614348, DE-FG02-97ER41033.

  20. Pseudo-Kähler Quantization on Flag Manifolds

    Science.gov (United States)

    Karabegov, Alexander V.

    A unified approach to geometric, symbol and deformation quantizations on a generalized flag manifold endowed with an invariant pseudo-Kähler structure is proposed. In particular cases we arrive at Berezin's quantization via covariant and contravariant symbols.

  1. Regional lung function (133Xe-radiospirometry) in bronchial cancer

    International Nuclear Information System (INIS)

    Arborelius, M.; Kristersson, S.; Lindell, S.E.

    1976-01-01

    In a prospective study of all patients with bronchial cancer in the city of Malmoe, all patients considered for surgery were examined with regard to overall function (conventional spirometry) and regional lung function (133-Xe-radiospirometry). Out of 116 consecutive cases examined with 133-Xe-radiospirometry before surgery,

  2. Kr and Xe isotopes from spontaneous fission of 248Cm and 250Cf

    International Nuclear Information System (INIS)

    Srinivasan, B.

    1980-01-01

    Relative yields of Kr and Xe isotopes from the spontaneous fission of 248 Cm and 250 Cf have been determined mass spectrometrically. The yields are as follows: 83 Kr/ 84 Kr/ 85 Kr/ 86 Kr = 0.223/0.458/0.596/ identical 1.00 and 0.306/0.582/0.793/ identical 1.00; 131 Xe/ 134 Xe/ 136 Xe = 0.486/0.819/1.075 identical 1.00 and 0.343/0.506/0.851/ identical 1.00 from 248 Cm and 250 Cf, respectively. The Xe yields from 248 Cm agree with an earlier determination by Leich et al. Neither of these yield patterns matches that of fissiogenic Kr and Xe in carbonaceous chondrites and hence 248 Cm and 250 Cf are ruled out as progenitors of the meteoritic Kr and Xe. In general, none of the spontaneously fissioning nuclides of actinide elements can be identified as a possible progenitor. Even the mixtures of actinides, including a combination of 248 Cm and 250 Cm, are unsuitable. The origin of anomalous Kr and Xe in carbonaceous chondrites must then be traced either to the spontaneous fission of a superheavy element or to peculiarities in specific nucleosynthetic reactions. (orig.)

  3. The Full Kostant-Toda Hierarchy on the Positive Flag Variety

    Science.gov (United States)

    Kodama, Yuji; Williams, Lauren

    2015-04-01

    We study some geometric and combinatorial aspects of the solution to the full Kostant-Toda (f-KT) hierarchy, when the initial data is given by an arbitrary point on the totally non-negative (tnn) flag variety of . The f-KT flows on the tnn flag variety are complete, and we show that their asymptotics are completely determined by the cell decomposition of the tnn flag variety given by Rietsch (Total positivity and real flag varieties. Ph.D. Thesis, Massachusetts Institute of Technology, Cambridge, 1998). Our results represent the first results on the asymptotics of the f-KT hierarchy (and even the f-KT lattice); moreover, our results are not confined to the generic flow, but cover non-generic flows as well. We define the f-KT flow on the weight space via the moment map, and show that the closure of each f-KT flow forms an interesting convex polytope which we call a Bruhat interval polytope. In particular, the Bruhat interval polytope for the generic flow is the permutohedron of the symmetric group . We also prove analogous results for the full symmetric Toda hierarchy, by mapping our f-KT solutions to those of the full symmetric Toda hierarchy. In the appendix we show that Bruhat interval polytopes are generalized permutohedra, in the sense of Postnikov (Int. Math. Res. Not. IMRN (6):1026-1106, 2009).

  4. Swedish Seafarers' Commitment to Work in Times of Flagging out

    Directory of Open Access Journals (Sweden)

    C. Hult

    2014-03-01

    Full Text Available This study takes its departure in the difficulties to recruit and retain qualified senior seafarers in the Swedish shipping sector. The study focus is on seafarers' motivation at work for the specific shipping company (organizational commitment, and seafarers' motivation towards their occupation (occupational commitment, in times of flagging out. It was hypothesized that the youngest seafarers and the oldest may be most sensitive to foreign registration of ships. Statistical analyses were employed, using a survey material of 1,309 Swedish seafarers randomly collected in 2010 from a national register of seafarers. The results of the analyses show that flagging-out imposes a significant decline in organizational commitment for all seafarers. This decline is related to the perception of the social composition of crew. In addition, the oldest seafarers (age 55+ demonstrate diminished occupational commitment under a foreign flag. This decline is related to the degree of satisfaction with the social security structure. Occupational commitment among the youngest seafarers (age 19-30 is not affected by the nationality of flag. However, this type of commitment is decreasing by the time served on the same ship. This effect is partly related to a decline in satisfaction with the work content. In the concluding discussion, the findings are discussed in more details and recommendations are put forward.

  5. Using atypical symptoms and red flags to identify non-demyelinating disease.

    LENUS (Irish Health Repository)

    Kelly, Siobhan B

    2012-01-01

    Red flags and atypical symptoms have been described as being useful in suggesting alternative diagnoses to multiple sclerosis (MS) and clinically isolated syndrome (CIS); however, their diagnostic utility has not been assessed. The aim of this study was to establish the predictive value of red flags and the typicality\\/atypicality of symptoms at presentation in relation to the final diagnosis of patients referred with suspected MS.

  6. Molecular dynamics simulation of Xe bubble nucleation in nanocrystalline UO2 nuclear fuel

    International Nuclear Information System (INIS)

    Moore, Emily; René Corrales, L.; Desai, Tapan; Devanathan, Ram

    2011-01-01

    Highlights: ► We simulated the interactions of defects and fission gas with grain boundaries in nuclear fuel. ► We observed the formation of Xe bubble nuclei that are difficult to observe experimentally. ► The bubble nuclei form by vacancy-assisted diffusion of Xe atoms. ► We also observed the initial stages of grain boundary motion. ► The study offers insights to the design of nuclear fuel to control fission gas release. - Abstract: We have performed molecular dynamics (MD) simulations to investigate the dynamical interactions between vacancy defects, fission gas atoms (Xe), and grain boundaries in a model of polycrystalline UO 2 nuclear fuel with average grain diameter of about 20 nm. We followed the mobility and aggregation of Xe atoms in the vacancy-saturated model compound for up to 2 ns. During this time we observed the aggregation of Xe atoms into nuclei, which are possible precursors to Xe bubbles. The nucleation was driven by the migration of Xe atoms via vacancy-assisted diffusion. The Xe clusters aggregate faster than grain boundary diffusion rates and are smaller than experimentally observed bubbles. As the system evolves towards equilibrium, the Xe atom cluster growth slows down significantly, and the lattice relaxes around the cluster. These simulations provide insights into fundamental physical processes that are inaccessible to experiment.

  7. Frobenius splitting of thick flag manifolds of Kac-Moody algebras

    OpenAIRE

    Kato, Syu

    2017-01-01

    We explain that the Pl\\"ucker relations provide the defining equations of the thick flag manifold associated to a Kac-Moody algebra. This naturally transplant the result of Kumar-Mathieu-Schwede about the Frobenius splitting of thin flag manifolds to the thick case. As a consequence, we provide a description of the global sections of line bundles of a thick Schubert variety as conjectured in Kashiwara-Shimozono [Duke Math. J. 148 (2009)]. This also yields the existence of a compatible basis o...

  8. 129 Xe-NMR of carbon black filled elastomers

    International Nuclear Information System (INIS)

    Sperling-Ischinsky, K.; Veeman, W.S.

    1999-01-01

    It is shown that 129 Xe-NMR is a powerful tool to investigate carbon black and carbon black filled elastomers. For the carbon black material itself the 129 Xe chemical shift of xenon adsorbed at the surface of carbon black aggregates yields information about the relative average pore size of the carbon black aggregates. The experimental 129 Xe-NMR results of carbon black filled ethylene-propylene-diene (EPDM) can be explained when it is assumed that the xenon atoms in the bound EPDM fraction exchange rapidly on the NMR time scale between a state where they are adsorbed on the carbon black surface and a state in which they are absorbed in the EPDM layer. This would imply that the carbon black aggregates are not completely covered with EPDM chains. (author)

  9. Level structures of neutron-rich Xe isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, I.; Lister, C.J.; Morss, L.R. [and others

    1995-08-01

    The level structures of neutron-rich Xe isotopes were determined by observing prompt gamma-ray coincidences in {sup 248}Cm fission fragments. A 5-mg {sup 248}Cm, in the form of {sup 248}Cm-KCl pellet, was placed inside Eurogam array which consisted of 45 Compton-suppressed Ge detectors and 5 Low-Energy Photon Spectrometers. Transitions in Xe isotopes were identified by the appearance of new peaks in the {gamma}-ray spectra obtained by gating on the gamma peaks of the complementary Mo fragments.

  10. 128Xe Lifetime Measurement Using the Coulex-Plunger Technique in Inverse Kinematics

    International Nuclear Information System (INIS)

    Konstantinopoulos, T.; Lagoyannis, A.; Harissopulos, S.; Dewald, A.; Rother, W.; Ilie, G.; Jones, P.; Rakhila, P.; Greenlees, P.; Grahn, T.; Julin, R.; Balabanski, D. L.

    2008-01-01

    The lifetimes of the lowest collective yrast and non-yrast states in 128 Xe were measured in a Coulomb excitation experiment using the recoil distance method (RDM) in inverse kinematics. Hereby, the Cologne plunger apparatus was employed together with the JUROGAM spectrometer. Excited states in 128 Xe were populated using a 128 Xe beam impinging on a nat Fe target with E( 128 Xe)≅525 MeV. Recoils were detected by means of an array of solar cells placed at forward angles. Recoil-gated γ-spectra were measured at different plunger distances

  11. 128Xe Lifetime Measurement Using the Coulex-Plunger Technique in Inverse Kinematics

    Science.gov (United States)

    Konstantinopoulos, T.; Lagoyannis, A.; Harissopulos, S.; Dewald, A.; Rother, W.; Ilie, G.; Jones, P.; Rakhila, P.; Greenlees, P.; Grahn, T.; Julin, R.; Balabanski, D. L.

    2008-05-01

    The lifetimes of the lowest collective yrast and non-yrast states in 128Xe were measured in a Coulomb excitation experiment using the recoil distance method (RDM) in inverse kinematics. Hereby, the Cologne plunger apparatus was employed together with the JUROGAM spectrometer. Excited states in 128Xe were populated using a 128Xe beam impinging on a natFe target with E(128Xe)~525 MeV. Recoils were detected by means of an array of solar cells placed at forward angles. Recoil-gated γ-spectra were measured at different plunger distances.

  12. Red flags in detecting credit cooperative fraud: the perceptions of internal auditors

    Directory of Open Access Journals (Sweden)

    Cristian Baú Dal Magro

    2017-07-01

    Full Text Available Purpose – Red flags are mechanisms that can be used by internal auditors for early detection of possible fraud. In this context, the aim of this study was to identify the relevance credit unions’ internal auditors attribute to red flags in assessing fraud risk. Design/methodology/approach – This article is characterized as descriptive concerning its goals, as a survey as to is procedures, and as quantitative in reference to its approach to the problem. The sample onsists of 51 internal auditors working in Credit Union Centers in southern Brazil. Findings – Results indicate that, in the assessment of fraud risk, internal auditors attribute greater importance to red flags referring to operational activities and internal control procedures. In addition, it is suggested that internal auditors are not impartial concerning their perception of relevance of most of the warning signs of the possibility of fraud. Originality/value – The findings contribute by demonstrating to internal auditors the need for greater attention to the use of red flags as auditing tools.

  13. Decay of 132Cs and nuclear structure of 132Xe

    International Nuclear Information System (INIS)

    Cruz, M.T.F. da; Goldman, I.D.

    1989-02-01

    Gamma spectroscopy, coincidence and angular correlation experiments were performed, in an extensive study of 132 Cs decay. The population intensities of states in 132 Ba were measured, some upper limits were determined and the value of the transition to the 4 1 + state of 132 Ba has drastically changed. A new gamma transition of 688 KeV was detected and located in the level scheme of 132 Xe. The angular correlation measurements were performed with a Ge(Li)-NaI(Tl) spectrometer and helped in choosing the spin value for the 1804 KeV state of 132 Xe. Kumar-Baranger-type calculations were performed for the 132 Xe fairly good results. The resulting potential energy surface for 132 Xe is very different from that of Gneuss and Greiner model, suggesting the need for any quadrupole moment measurement for this nucleus. (author) [pt

  14. Imaging Human Brain Perfusion with Inhaled Hyperpolarized 129Xe MR Imaging.

    Science.gov (United States)

    Rao, Madhwesha R; Stewart, Neil J; Griffiths, Paul D; Norquay, Graham; Wild, Jim M

    2018-02-01

    Purpose To evaluate the feasibility of directly imaging perfusion of human brain tissue by using magnetic resonance (MR) imaging with inhaled hyperpolarized xenon 129 ( 129 Xe). Materials and Methods In vivo imaging with 129 Xe was performed in three healthy participants. The combination of a high-yield spin-exchange optical pumping 129 Xe polarizer, custom-built radiofrequency coils, and an optimized gradient-echo MR imaging protocol was used to achieve signal sensitivity sufficient to directly image hyperpolarized 129 Xe dissolved in the human brain. Conventional T1-weighted proton (hydrogen 1 [ 1 H]) images and perfusion images by using arterial spin labeling were obtained for comparison. Results Images of 129 Xe uptake were obtained with a signal-to-noise ratio of 31 ± 9 and demonstrated structural similarities to the gray matter distribution on conventional T1-weighted 1 H images and to perfusion images from arterial spin labeling. Conclusion Hyperpolarized 129 Xe MR imaging is an injection-free means of imaging the perfusion of cerebral tissue. The proposed method images the uptake of inhaled xenon gas to the extravascular brain tissue compartment across the intact blood-brain barrier. This level of sensitivity is not readily available with contemporary MR imaging methods. © RSNA, 2017.

  15. Quadrupole photoionization of endohedral Xe-C60

    International Nuclear Information System (INIS)

    Govil, Karan; Deshmukh, P C

    2009-01-01

    The effect of an endohedral confinement on the quadrupole photoionization of atomic Xe is studied using the relativistic random phase approximation (RRPA). The atom's confinement is modelled by placing atomic Xe at the centre of a C 60 cage represented by an annular potential around it. A new confinement resonance is reported in the 4p quadrupole cross-section along with 'correlation confinement resonances' in 4d, 5s and 5p photoionizations at about 185 eV. The effect of the confinement on the non-dipole photoelectron angular distribution parameter γ is also reported.

  16. Fourier photospectroscopy of Xe-C{sub 60} through a Xe 4d resonance window: theory versus recent experiment

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Aakash B; Chakraborty, Himadri S, E-mail: himadri@nwmissouri.edu [Center for Innovation and Entrepreneurship, Department of Chemistry and Physics, Northwest Missouri State University, Maryville, Missouri 64468 (United States)

    2011-10-14

    The photoionization cross section of endohedral Xe-C{sub 60} over a Xe 4d giant resonance energy region, calculated in the time-dependent local density approximation, is compared with recent measurements (Kilcoyne et al 2010 Phys. Rev. Lett. 105 213001). An analysis based on the Fourier transforms of oscillatory cross sections is performed to derive a number of inherent similarities between the prediction and the data, including a large beating-type oscillation and several others of intermediate size. Results stress the need for more accurate measurements to access the wealth of information about the geometry of the system. (fast track communication)

  17. Research

    African Journals Online (AJOL)

    ebutamanya

    11 août 2015 ... La numération plaquettaire a été réalisée sur automate Sysmex XE. 5000. Agrégométrie. L'étude de l'agrégation plaquettaire a été réalisée sur un thrombo- agrégomètre TA 4V (SD Medical, France) dans l'intervalle de 2 heures suivant le prélèvement. Ce test a été effectué sur plasma riche en plaquettes ...

  18. 129Xe on the outgassing of the atmosphere

    International Nuclear Information System (INIS)

    Thomsen, L.

    1980-01-01

    Because of the short half-life of its parent ( 129 I, 17 m.y.) and its own chemical inertness, 129 Xe offers unique insight into the problem of the outgassing history of the earth's atmosphere. Because the current atmosphere is different in Xe isotopic patterns than is the interior, the present atmosphere must have been largely outgassed before these patterns finished changing, that is, very early in earth history. Furthermore, there can have been no significant delay in the onset of outgassing; that is, the earth must have been initially hot. Because ancient sedimentary rocks indicate that the atmospheric Xe patterns have not changed substantially for over 3 b.y., models presuming a separate, lower mantle reservoir do not alter these conclusions. Similar conclusions have been reached before but have always carried a heavier burden of debatable assumptions

  19. Optical properties of implanted Xe color centers in diamond

    Science.gov (United States)

    Sandstrom, Russell; Ke, Li; Martin, Aiden; Wang, Ziyu; Kianinia, Mehran; Green, Ben; Gao, Wei-bo; Aharonovich, Igor

    2018-03-01

    Optical properties of color centers in diamond have been the subject of intense research due to their promising applications in quantum photonics. In this work we study the optical properties of Xe related color centers implanted into nitrogen rich (type IIA) and an ultrapure, electronic grade diamond. The Xe defect has two zero phonon lines at ∼794 nm and 811 nm, which can be effectively excited using both green and red excitation, however, its emission in the nitrogen rich diamond is brighter. Near resonant excitation is performed at cryogenic temperatures and luminescence is probed under strong magnetic field. Our results are important towards the understanding of the Xe related defect and other near infrared color centers in diamond.

  20. 75 FR 66125 - Federal Land Managers' Air Quality Related Values Work Group (FLAG)

    Science.gov (United States)

    2010-10-27

    ... pollutants that could affect the health and status of resources in areas managed by the three agencies... Work Group (FLAG) AGENCY: National Park Service, Interior. ACTION: Notice of availability of final... Public Comments document. The Federal Land Managers' Air Quality Related Values Work Group (FLAG) was...

  1. Damage evolution in Xe-ion irradiated rutile (TiO2) single crystals

    International Nuclear Information System (INIS)

    Li, F.; Sickafus, K.E.; Evans, C.R.; Nastasi, M.

    1999-01-01

    Rutile (TiO 2 ) single crystals with (110) orientation were irradiated with 360 keV Xe 2+ ions at 300 K to fluences ranging from 2 x 10 19 to 1 x 10 20 Xe/m 2 . Irradiated samples were analyzed using: (1) Rutherford backscattering spectroscopy combined with ion channeling analysis (RBS/C); and (2) cross-sectional transmission electron microscopy (XTEM). Upon irradiation to a fluence of 2 x 10 19 Xe/m 2 , the sample thickness penetrated by the implanted ions was observed to consist of three distinct layers: (1) a defect-free layer at the surface (thickness about 12 nm) exhibiting good crystallinity; (2) a second layer with a low density of relatively large-sized defects; and (3) a third layer consisting of a high concentration of small defects. After the fluence was increased to 7 x 10 19 Xe/m 2 , a buried amorphous layer was visible by XTEM. The thickness of the amorphous layer was found to increase with increasing Xe ion fluence. The location of this buried amorphous layer was found to coincide with the measured peak in the Xe concentration (measured by RBS/C), rather than with the theoretical maximum in the displacement damage profile. This observation suggests the implanted Xe ions may serve as nucleation sites for the amorphization transformation. The total thickness of the damaged microstructure due to ion irradiation was always found to be much greater than the projected range of the Xe ions. This is likely due to point defect migration under the high stresses induced by ion implantation

  2. The permanent electric dipole moment of the neutron and atomic 129Xe

    International Nuclear Information System (INIS)

    Heckel, B.

    1984-01-01

    Recently the Seattle group has measured the permanent edm of atomic 129 Xe to be d /sub Xe/ = (-0.3 + or - 1.1) x 10 -26 cm. This measurement provides an improvement by a factor of 10 4 over the best previous measurement of an atomic edm. The edm of Xe is most sensitive to a T-violating electron-nucleon interaction, but can also be generated by an intrinsic electron edm or an edm of the Xe nucleus. In the second half of this presentation, each of these mechanisms will be briefly discussed and a description of the experiment will be given

  3. Reliance communications' flag telecom to provide ethernet link between CERN and TIFR

    CERN Multimedia

    2007-01-01

    "Flag Telecom Group Limited (Flag), the undersea cable network arm of Anil Ambani-le Reliance Communications, has announced a landmark deal with CERn (Conseil Européen pour la Recheche Nucléaire), the European organisation for nuclear research based in Geneva, Switzerland and the Tata institute of Fundamental Research (TIFR) in Mumbai to provide gigabit Ethernet connectivity between the two." (1 page)

  4. Analysis of XeC1 Emission in a Hollow Cathode Discharge.

    Science.gov (United States)

    1981-06-01

    excited homopolar molecule, e.g., Xe2 , Hg2 The term exciplex refers to an electronically excited heteropolar complex, e.g., KrF , XeOH , XeCl , which...frequently overlooked and both homopolar and heteropolar systems are commonly referred to as excimers, Excimers are formed by the interaction between two...mode and a non-scanning mode. Scanning is performed using a 1 rpm motor and produces plots of in- tensity versus wavelength. The non-scanning mode is

  5. Effect of high Xe-concentration in a plasma display panel with a SrCaO cold cathode

    International Nuclear Information System (INIS)

    Uchida, Giichiro; Kajiyama, Hiroshi; Shinoda, Tsutae; Uchida, Satoshi; Akiyama, Toshiyuki

    2010-01-01

    We present here measurements of high Xe-contents plasma display panel (PDP) with SrCaO cold cathode. Luminous efficacy (η) shows a two-step increase with Xe-concentration in Ne/Xe gas mixture: η drastically increases up to Xe-concentration of 30% (Xe: 30%), and then attains 5 lm/W at the highest Xe-concentration of Xe: 100%. The high performance PDP with Xe: 100% can be operated at low applied voltage between 230 and 377 V due to the high secondary electron emission from the SrCaO cathode. Emission measurements clearly show the change in discharge characteristics at Xe: 30%, where the discharge changes from a Ne/Xe mixture discharge to an almost pure Xe discharge, and the vacuum ultraviolet (VUV) radiation from the combination of resonance and excimer radiations to only excimer radiation. Theoretical analysis solving Boltzmann equation for electron demonstrates that increasing Xe-concentration enhances the collision frequency for electron impact excitation directly from ground state to lower levels concerned with the VUV radiation, resulting in a drastic increase in luminous efficacy up to Xe: 30%. Also, one-dimensional fluid simulation of a Ne/Xe dielectric barrier discharge clearly shows that a combination of high secondary electron emission cathode and high Xe-concentration is quite effective for high VUV radiation efficiency because it induces a drastic increase in electron-heating efficiency.

  6. Nuclear Structure of 124Xe Studied with β+/EC-Decay

    Science.gov (United States)

    Radich, A. J.; Garrett, P. E.; Allmond, J. M.; Andreoiu, C.; Ball, G. C.; Bianco, L.; Bildstein, V.; Chagnon-Lessard, S.; Cross, D. S.; Diaz Varela, A.; Dunlop, R.; Finlay, P.; Garnsworthy, A. B.; Hackman, G.; Hadinia, B.; Jigmeddorj, B.; Laffoley, A. T.; Leach, K. G.; Michetti-Wilson, J.; Orce, J. N.; Rajabali, M. M.; Rand, E.; Starosta, K.; Sumithrarachchi, C. S.; Svensson, C. E.; Triambak, S.; Wang, Z. M.; Wood, J. L.; Wong, J.; Williams, S. J.; Yates, S. W.

    The nuclear structure of 124Xe was investigated using γ-ray spectroscopy following the β+/EC-decay of 124Cs. A very high-statistics data set was collected and γγ coincidence data was analyzed, greatly adding to the 124Xe level scheme. A new decay branch from the high-spin isomer of 124Cs was observed as well as weak E2 transitions into excited 0+ states in 124Xe. B(E2) transition strengths of such low-spin transitions are very important in determining collective properties, which are currently poorly characterized in the region of neutron-deficient xenon isotopes.

  7. Present status of the {sup 129}Xe comagnetometer development for neutron EDM measurement

    Energy Technology Data Exchange (ETDEWEB)

    Mihara, M., E-mail: mihara@vg.phys.sci.osaka-u.ac.jp [Osaka University, Department of Physics (Japan); Masuda, Y. [Institute of Particle and Nuclear Studies (IPNS), High Energy Accelerator Research Organization (KEK) (Japan); Matsuta, K. [Osaka University, Department of Physics (Japan); Kawasaki, S.; Watanabe, Y. [Institute of Particle and Nuclear Studies (IPNS), High Energy Accelerator Research Organization (KEK) (Japan); Hatanaka, K.; Matsumiya, R. [Osaka University, Research Center for Nuclear Physics (RCNP) (Japan)

    2016-12-15

    A {sup 129}Xe comagnetometer designed for the measurement of neutron electric dipole moment (nEDM) as precisely as 1 × 10{sup −27}e cm is presented. Highly nuclear spin polarized {sup 129}Xe are introduced into an EDM cell where the {sup 129}Xe spin precession is detected by means of the two-photon transition. The geometric phase effect (GPE) which generates the false nEDM was quantitatively discussed and the systematic error of nEDM from the GPE was estimated considering the buffer-gas suppression due to Xe atomic collisions. Research and development are in progress to construct the {sup 129}Xe comagnetometer with a field sensitivity of 0.3 fT. At present, about 70 % nuclear spin polarized {sup 129}Xe atoms have been obtained in a spin exchange opitial pumping cell, that are in the process of being transferred into the EDM cell via a cold trap.

  8. Testing ALE code FLAG with analytical self-similar solutions of 2D magnetized implosion

    Energy Technology Data Exchange (ETDEWEB)

    Bereznyak, Andrey [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Gianakon, Thomas Arthur [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Rousculp, Christopher L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Cooley, James Hamilton [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Giuliani, John [Naval Research Lab. (NRL), Washington, DC (United States)

    2018-01-04

    The goal of this collaboration was to provide a mechanism to verify the MHD implementation in FLAG and improve the FLAG MHD packages as need to meet broader LANL institutional goals. These three Magnetic Noh problems are proving immensely useful.

  9. Ion mobilities in Xe/Ne and other rare-gas mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Piscitelli, D; Pitchford, L C [Centre de Physique des Plasmas et Applications de Toulouse (CPAT), UMR 5002 CNRS, 118 route de Narbonne, 31062 Toulouse (France); Phelps, A V [JILA, University of Colorado and National Institute of Technology, Boulder, Colorado (United States); Urquijo, J de [Centro de Ciencias Fisicas, Universidad Nacional Autonoma de Mexico, Post Office Box 48-3, 62251, 80309-0440 Cuernavaca, Moreno (Mexico); Basurto, E [Departmento de Ciencias Basicas, Universidad Autonoma Metropolitana, 02200 Mexico Distrito Federal (Mexico)

    2003-10-01

    The ion mobility or drift velocity data important for modeling glow discharges in rare gas mixtures are not generally available, nor are the ion-neutral scattering cross sections needed to calculate these data. In this paper we propose a set of cross sections for Xe{sup +} and Ne{sup +} collisions with Xe and Ne atoms. Ion mobilities at 300 K calculated using this cross section set in a Monte Carlo simulation are reported for reduced field strengths, E/N, up to 1500x10{sup -21} V m{sup 2}, in pure gases and in Xe/Ne mixtures containing 5% and 20% Xe/Ne, which are mixtures of interest for plasma display panels (PDPs). The calculated Xe{sup +} mobilities depend strongly on the mixture composition, but the Ne{sup +} mobility varies only slightly with increasing Xe in the mixture over the range studied here. The mobilities in pure gases compare well with available experimental values, and mobilities in gas mixtures at low E/N compare well with our recent measurements which will be published separately. Results from these calculations of ion mobilities are used to evaluate the predictions of Blanc's law and of the mixture rule proposed by Mason and Hahn [Phys. Rev. A 5, 438 (1972)] for determining the ion mobilities in mixtures from a knowledge of the mobilities in each of the pure gases. The mixture rule of Mason and Hahn is accurate to better than 10% at high field strengths over a wide range of conditions of interest for modeling PDPs. We conclude that a good estimate of ion mobilities at high E/N in Xe/Ne and other binary rare gas mixtures can be obtained using this mixture rule combined with known values of mobilities in parent gases and with the Langevin form for mobility of rare gas ions ion in other gases. This conclusion is supported by results in Ar/Ne mixtures which are also presented here.

  10. Hyperpolarized 129Xe MRI: A viable functional lung imaging modality?

    International Nuclear Information System (INIS)

    Patz, Samuel; Hersman, F. William; Muradian, Iga; Hrovat, Mirko I.; Ruset, Iulian C.; Ketel, Stephen; Jacobson, Francine; Topulos, George P.; Hatabu, Hiroto; Butler, James P.

    2007-01-01

    The majority of researchers investigating hyperpolarized gas MRI as a candidate functional lung imaging modality have used 3 He as their imaging agent of choice rather than 129 Xe. This preference has been predominantly due to, 3 He providing stronger signals due to higher levels of polarization and higher gyromagnetic ratio, as well as its being easily available to more researchers due to availability of polarizers (USA) or ease of gas transport (Europe). Most researchers agree, however, that hyperpolarized 129 Xe will ultimately emerge as the imaging agent of choice due to its unlimited supply in nature and its falling cost. Our recent polarizer technology delivers vast improvements in hyperpolarized 129 Xe output. Using this polarizer, we have demonstrated the unique property of xenon to measure alveolar surface area noninvasively. In this article, we describe our human protocols and their safety, and our results for the measurement of the partial pressure of pulmonary oxygen (pO 2 ) by observation of 129 Xe signal decay. We note that the measurement of pO 2 by observation of 129 Xe signal decay is more complex than that for 3 He because of an additional signal loss mechanism due to interphase diffusion of 129 Xe from alveolar gas spaces to septal tissue. This results in measurements of an equivalent pO 2 that accounts for both traditional T 1 decay from pO 2 and that from interphase diffusion. We also provide an update on new technological advancements that form the foundation for an improved compact design polarizer as well as improvements that provide another order-of-magnitude scale-up in xenon polarizer output

  11. Direct Observation of Xe and Kr Adsorption in a Xe-Selective Microporous Metal-Organic Framework

    NARCIS (Netherlands)

    Chen, X.; Plonka, A.M.; Banerjee, D.; Krishna, R.; Schaef, H.T.; Ghose, S.; Thallapally, P.K.; Parise, J.B.

    2015-01-01

    The cryogenic separation of noble gases is energy-intensive and expensive, especially when low concentrations are involved. Metal organic frameworks (MOFs) containing polarizing groups within their pore spaces are predicted to be efficient Xe/Kr solid,state adsorbents, but no experimental insights

  12. Race Discourse and the US Confederate Flag

    Science.gov (United States)

    Holyfield, Lori; Moltz, Matthew Ryan; Bradley, Mindy S.

    2009-01-01

    Research reveals that racial hierarchies and "color-blind" racism is maintained through discourse. The current study utilizes exploratory data from focus groups in a predominantly white southern university in the United States to examine race talk, the Confederate Flag, and the construction of southern white identity. Drawing from…

  13. Magnetic dipole strength in 128Xe and 134Xe in the spin-flip resonance region

    Science.gov (United States)

    Massarczyk, R.; Rusev, G.; Schwengner, R.; Dönau, F.; Bhatia, C.; Gooden, M. Â. E.; Kelley, J. Â. H.; Tonchev, A. Â. P.; Tornow, W.

    2014-11-01

    The magnetic dipole strength in the energy region of the spin-flip resonance is investigated in 128Xe and 134Xe using quasimonoenergetic and linearly polarized γ -ray beams at the High-Intensity γ -Ray Source facility in Durham, North Carolina, USA. Absorption cross sections were deduced for the magnetic and electric and dipole strength distributions separately for various intervals of excitation energy, including the strength of states in the unresolved quasicontinuum. The magnetic dipole strength distributions show structures resembling a resonance in the spin-flip region around an excitation energy of 8 MeV. The electric dipole strength distributions obtained from the present experiments are in agreement with the ones deduced from an earlier experiment using broad-band bremsstrahlung instead of a quasimonoenergetic beam. The experimental magnetic and electric dipole strength distributions are compared with phenomenological approximations and with predictions of a quasiparticle random phase approximation in a deformed basis.

  14. Noble gas bond and the behaviour of XeO3 under pressure.

    Science.gov (United States)

    Hou, Chunju; Wang, Xianlong; Botana, Jorge; Miao, Maosheng

    2017-10-18

    Over the past few decades, the concept of hydrogen bonds, in which hydrogen is electrophilic, has been extended to halogen bonds, chalcogen bonds and pnicogen bonds. Herein, we show that such a non-covalent bonding also exists in noble gas compounds. Using first principles calculations, we illustrate the OXe-O bond in molecular crystal XeO 3 and its effect on the behavior of this compound under pressure. Our calculations show that the covalent Xe-O bond lengths were elongated with increasing pressure and correspondingly the Xe-O stretching vibration frequencies were red shifted, which is similar to the change of H-bonds under pressure. The OXe-O bond and related hopping of O between neighboring Xe sites also correspond to the structural changes in the XeO 3 compounds at about 2 GPa. Our study extends the concept of hydrogen bonding to include all p-block elements and show a new bonding type for Noble gas elements in which it acts as an electrophilic species.

  15. Customization of Advia 120 thresholds for canine erythrocyte volume and hemoglobin concentration, and effects on morphology flagging results.

    Science.gov (United States)

    Grimes, Carolyn N; Fry, Michael M

    2014-12-01

    This study sought to develop customized morphology flagging thresholds for canine erythrocyte volume and hemoglobin concentration [Hgb] on the ADVIA 120 hematology analyzer; compare automated morphology flagging with results of microscopic blood smear evaluation; and examine effects of customized thresholds on morphology flagging results. Customized thresholds were determined using data from 52 clinically healthy dogs. Blood smear evaluation and automated morphology flagging results were correlated with mean cell volume (MCV) and cellular hemoglobin concentration mean (CHCM) in 26 dogs. Customized thresholds were applied retroactively to complete blood (cell) count (CBC) data from 5 groups of dogs, including a reference sample group, clinical cases, and animals with experimentally induced iron deficiency anemia. Automated morphology flagging correlated more highly with MCV or CHCM than did blood smear evaluation; correlation with MCV was highest using customized thresholds. Customized morphology flagging thresholds resulted in more sensitive detection of microcytosis, macrocytosis, and hypochromasia than default thresholds.

  16. Neutron-induced Backgrounds in 134Xe for Large-Scale Neutrinoless Double-Beta Decay Experiments

    Science.gov (United States)

    Moriguchi, Nina; Kidd, Mary; Tornow, Werner

    2016-09-01

    136Xe is used in large neutrinoless double-beta (0 νββ) decay experiments, such as KamLAND- Zen and EXO 200. Though highly purified, 136Xe still contains a significant amount of 134Xe. Recently, a new nuclear energy level was found in 134Xe. If 134Xe decays from this proposed excited state, it will emit a 2485.7 keV gamma ray. Because this energy lies near the region of interest of 136Xe νββ decay experiments (Q value 2457.8 keV), it could make a significant contribution to the background. A purified gaseous sample of 134Xe will be irradiated with neutrons of an incident energy of 4.0 MeV at Triangle Universities Nuclear Laboratory and monitored with high-purity germanium detectors. The spectra obtained from these detectors will be analyzed for the presence of the 2581 keV gamma ray. We will report on the status of this experiment. Future plans include expanding this measurement to higher initial neutron energies. Tennesse Tech University CISE Grant program.

  17. Flag-dipole and flagpole spinor fluid flows in Kerr spacetimes

    Energy Technology Data Exchange (ETDEWEB)

    Rocha, Roldão da, E-mail: roldao.rocha@ufabc.edu.br [Universidade Federal do ABC, CMCC (Brazil); Cavalcanti, R. T., E-mail: rogerio.cavalcanti@ufabc.edu.br [Universidade Federal do ABC, CCNH (Brazil)

    2017-03-15

    Flagpole and flag-dipole spinors are particular classes of spinor fields that has been recently used in different branches of theoretical physics. In this paper, we study the possibility and consequences of these spinor fields to induce an underlying fluid flow structure in the background of Kerr spacetimes. We show that flag-dipole spinor fields are solutions of the equations of motion in this context. To our knowledge, this is the second time that this class of spinor field appears as a physical solution, the first one occurring as a solution of the Dirac equation in ESK gravities.

  18. Sputtering of Au induced by single Xe ion impacts

    International Nuclear Information System (INIS)

    Birtcher, R. C.; Donnelly, S. E.

    1999-01-01

    Sputtering of Au thin films has been determined for Xe ions with energies between 50 and 600 keV. In-situ transmission electron microscopy was used to observe sputtered Au during deposition on a carbon foil near the specimen. Total reflection and transmission sputtering yields for a 62 nm thick Au thin film were determined by ex-situ measurement of the total amount of Au on the carbon foils. In situ observations show that individual Xe ions eject Au nanoparticles as large as 7 nm in diameter with an average diameter of approximately 3 nm. Particle emission correlates with crater formation due to single ion impacts. Nanoparticle emission contributes significantly to the total sputtering yield for Xe ions in this energy range in either reflection or transmission geometry

  19. A high volume, batch mode {sup 129}Xe polarizer

    Energy Technology Data Exchange (ETDEWEB)

    Wojna-Pelczar, Anna, E-mail: anna.wojna.pelczar@mail.muni.cz [Central European Institute of Technology, Masaryk University, Brno (Czech Republic); Formerly: Marian Smoluchowski Institute of Physics, Jagiellonian University, Kraków (Poland); Pałasz, Tadeusz [Marian Smoluchowski Institute of Physics, Jagiellonian University, Kraków (Poland)

    2017-06-01

    Numerous designs of optical gas polarizers have been proposed, broadening possible applications of the hyperpolarized gases as contrast agents in magnetic resonance imaging. We present a home–made {sup 129}Xe polarizer based on the spin exchange optical pumping method. The polarizer operates under 1 bar of the gas mixture (at the maximum temperature of 160 °C) in a high volume optical cell (5025 cm{sup 3}). Approximately 100 cm{sup 3} of {sup 129}Xe polarized at 1.50±0.37% is produced in a single cycle of polarization. Operation under standard pressure imposes polarization transfer mainly via van der Waals molecules, resulting in the efficient spin exchange between rubidium and {sup 129}Xe atoms. The design, construction and operation of the polarizer are described in details.

  20. Angle Performance on Optima XE

    International Nuclear Information System (INIS)

    David, Jonathan; Satoh, Shu

    2011-01-01

    Angle control on high energy implanters is important due to shrinking device dimensions, and sensitivity to channeling at high beam energies. On Optima XE, beam-to-wafer angles are controlled in both the horizontal and vertical directions. In the horizontal direction, the beam angle is measured through a series of narrow slits, and any angle adjustment is made by steering the beam with the corrector magnet. In the vertical direction, the beam angle is measured through a high aspect ratio mask, and any angle adjustment is made by slightly tilting the wafer platen during implant.Using a sensitive channeling condition, we were able to quantify the angle repeatability of Optima XE. By quantifying the sheet resistance sensitivity to both horizontal and vertical angle variation, the total angle variation was calculated as 0.04 deg. (1σ). Implants were run over a five week period, with all of the wafers selected from a single boule, in order to control for any crystal cut variation.

  1. Six-day stability of erythrocyte and reticulocyte parameters in-vitro: a comparison of blood samples from healthy, iron-deficient, and thalassemic individuals.

    Science.gov (United States)

    Sudmann-Day, Åshild A; Piehler, Armin; Klingenberg, Olav; Urdal, Petter

    2015-05-01

    Stability for up to 6 days' storage of erythrocyte and reticulocyte parameters in samples from iron-deficient and thalassemic individuals has not yet been reported. This lack of knowledge challenges evaluation of the full blood count in referral samples for hemoglobinopathy evaluation. We therefore hereby present such sample stability data. We included fresh (less than 4 hours old) blood samples from eight healthy, eight iron-deficient, and 11 thalassemic individuals. A full blood count, including reticulocyte parameters, was performed on a Sysmex XE-2100 once daily during a 6-day storage period at room temperature. For healthy individuals, we also studied stability of refrigerated samples and investigated analytical and biological variation. Hemoglobin concentration, erythrocyte count, and mean corpuscular hemoglobin were stable for 6 days in all diagnostic groups. Mean corpuscular volume increased less in samples from iron-deficient individuals while the number of reticulocytes increased more in samples from thalassemic, as compared to healthy individuals. Ret-He stability depended on its baseline value. Within-person biological variation in samples from healthy individuals was low both for erythrocyte parameters and for reticulocyte hemoglobin, while higher for reticulocyte counts. Results for hemoglobin concentration, erythrocyte count, and mean corpuscular hemoglobin are reliable in hemoglobinopathy investigation of referred samples for up to 6 days. Storage time-dependent changes of other erythrocyte and reticulocyte parameters in blood samples from iron-deficient and thalassemic individuals differ from those of healthy individuals.

  2. Study of high-j neutron excitations outside 136Xe

    Science.gov (United States)

    Talwar, R.; Kay, B. P.; Mitchell, A. J.; Adachi, S.; Entwisle, J. P.; Fujita, Y.; Gey, G.; Noji, S.; Ong, H. J.; Schiffer, J. P.; Tamii, A.

    2017-09-01

    The character of single-neutron excitations outside of N = 82 has been studied using nucleon transfer reactions in terms of the energy centroid of their strength as well as the fragmentation of this strength among the actual states of the nucleus. However, extending the systematic study of the N = 83 isotones to 137Xe has been challenging due to xenon being a gas at room temperature. Though several attempts have been made, a quantitative determination of the spectroscopic factors for the neutron 9/2- and 13/2+ excitations in 137Xe is still lacking. In the present work, we report on a study of the 136Xe(α,3He)137Xe reaction carried out at 100 MeV to probe the l = 5 , 9/2- and l = 6 , 13/2+ single-neutron excitations. The experimental technique and results will be presented discussing them in context of the evolution of these single-neutron excitations and the influence of the tensor interaction on the neutron single-particle states as the proton orbits are filling. This work has been supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics, under Contract Number DE-AC02-06CH11357, the Australian Research Council Discovery Project 120104176, and the UK Science and Technology Facilities.

  3. Zeolitic Imidazolate Framework-8 (ZIF-8) Membranes for Kr/Xe Separation

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Ting; Feng, Xuhui; Elsaidi, Sameh K.; Thallapally, Praveen K.; Carreon, Moises A.

    2017-01-30

    Herein, we demonstrate that a prototypical type of metal organic framework, zeolitic imidazolate framework-8 (ZIF-8), in membrane form, can effectively separate Kr/Xe gas mixtures at industrially relevant compositions. The best membranes separated Kr/Xe mixtures with average Kr permeances as high as 1.5 × 10-8 ± 0.2 mol/m2 s Pa and average separation selectivities of 14.2 ± 1.9 for molar feed compositions corresponding to Kr/Xe ratio encountered typically in air. Molecular sieving, competitive adsorption, and differences in diffusivities were identified as the prevailing separation mechanisms. These membranes potentially represent a less-energy-intensive alternative to cryogenic distillation, which is the benchmark technology used to separate this challenging gas mixture. To our best knowledge, this is the first example of any metal organic membrane composition displaying separation ability for Kr/Xe gas mixtures.

  4. Experimental ion mobility measurements in Xe-CO2

    Science.gov (United States)

    Cortez, A. F. V.; Santos, M. A. G.; Veenhof, R.; Patra, R. N.; Neves, P. N. B.; Santos, F. P.; Borges, F. I. G. M.; Conde, C. A. N.

    2017-06-01

    Data on ion mobility is important to improve the performance of large volume gaseous detectors. In the present work the method, experimental setup and results for the ion mobility measurements in Xe-CO2 mixtures are presented. The results for this mixture show the presence of only one peak for all gas ratios of Xe-CO2, low reduced electric fields, E/N, 10-25 Td (2.4-6.1 kV·cm-1·bar-1), low pressures 6-8 Torr (8-10.6 mbar), at room temperature.

  5. Disintegration of C60 by Xe ion irradiation

    International Nuclear Information System (INIS)

    Kalish, R.; Samoiloff, A.; Hoffman, A.; Uzan-Saguy, C.

    1993-01-01

    The Changes in resistivity of fullerene (C 60 ) films subject to 320 keV Xe ion irradiation are investigated as a function of ion dose. From a comparison of this dependence with similar data on other Xe irradiated C containing insulating materials and with data on C implanted fused quartz, it is concluded that upon ion impact C 60 clusters completely disintegrate. This disintegration releases about 60 C atoms which disperse amongst the remaining intact C 60 spheres giving rise to hopping conductivity between isolated C atoms. 16 refs., 3 figs

  6. Trampoline motions in Xe-graphite(0 0 0 1) surface scattering

    Science.gov (United States)

    Watanabe, Yoshimasa; Yamaguchi, Hiroki; Hashinokuchi, Michihiro; Sawabe, Kyoichi; Maruyama, Shigeo; Matsumoto, Yoichiro; Shobatake, Kosuke

    2005-09-01

    We have investigated Xe scattering from the graphite(0 0 0 1) surface at hyperthermal incident energies using a molecular beam-surface scattering technique and molecular dynamics simulations. For all incident conditions, the incident Xe atom conserves the momentum parallel to the surface and loses approximately 80% of the normal incident energy. The weak interlayer potential of graphite disperses the deformation over the wide range of a graphene sheet. The dynamic corrugation induced by the collision is smooth even at hyperthermal incident energy; the graphene sheet moves like a trampoline net and the Xe atom like a trampoliner.

  7. Estuary 2100 Project, Phase 2: Building Partnerships for Resilient Watersheds

    Science.gov (United States)

    Information about the SFBWQP Estuary 2100 Project, Phase 2: Building Partnerships for Resilient Watersheds, part of an EPA competitive grant program to improve SF Bay water quality focused on restoring impaired waters and enhancing aquat

  8. Phloem Transport of Arsenic Species from Flag Leaf to Grain During Grain Filling

    Energy Technology Data Exchange (ETDEWEB)

    A Carey; G Norton; C Deacon; K Scheckel; E Lombi; T Punshon; M Guerinot; A Lanzirotti; M Newville; et al.

    2011-12-31

    Strategies to reduce arsenic (As) in rice grain, below concentrations that represent a serious human health concern, require that the mechanisms of As accumulation within grain be established. Therefore, retranslocation of As species from flag leaves into filling rice grain was investigated. Arsenic species were delivered through cut flag leaves during grain fill. Spatial unloading within grains was investigated using synchrotron X-ray fluorescence (SXRF) microtomography. Additionally, the effect of germanic acid (a silicic acid analog) on grain As accumulation in arsenite-treated panicles was examined. Dimethylarsinic acid (DMA) and monomethylarsonic acid (MMA) were extremely efficiently retranslocated from flag leaves to rice grain; arsenate was poorly retranslocated, and was rapidly reduced to arsenite within flag leaves; arsenite displayed no retranslocation. Within grains, DMA rapidly dispersed while MMA and inorganic As remained close to the entry point. Germanic acid addition did not affect grain As in arsenite-treated panicles. Three-dimensional SXRF microtomography gave further information on arsenite localization in the ovular vascular trace (OVT) of rice grains. These results demonstrate that inorganic As is poorly remobilized, while organic species are readily remobilized, from leaves to grain. Stem translocation of inorganic As may not rely solely on silicic acid transporters.

  9. Phloem transport of arsenic species from flag leaf to grain during grain filling

    Energy Technology Data Exchange (ETDEWEB)

    Carey, Anne-Marie; Norton, Gareth J.; Deacon, Claire; Scheckel, Kirk G.; Lombi, Enzo; Punshon, Tracy; Guerinot, Mary Lou; Lanzirotti, Antonio; Newville, Matt; Choi, Yongseong; Price, Adam H.; Meharg, Andrew A. (EPA); (U. South Australia); (Aberdeen); (UC); (Dartmouth)

    2011-09-20

    Strategies to reduce arsenic (As) in rice grain, below concentrations that represent a serious human health concern, require that the mechanisms of As accumulation within grain be established. Therefore, retranslocation of As species from flag leaves into filling rice grain was investigated. Arsenic species were delivered through cut flag leaves during grain fill. Spatial unloading within grains was investigated using synchrotron X-ray fluorescence (SXRF) microtomography. Additionally, the effect of germanic acid (a silicic acid analog) on grain As accumulation in arsenite-treated panicles was examined. Dimethylarsinic acid (DMA) and monomethylarsonic acid (MMA) were extremely efficiently retranslocated from flag leaves to rice grain; arsenate was poorly retranslocated, and was rapidly reduced to arsenite within flag leaves; arsenite displayed no retranslocation. Within grains, DMA rapidly dispersed while MMA and inorganic As remained close to the entry point. Germanic acid addition did not affect grain As in arsenite-treated panicles. Three-dimensional SXRF microtomography gave further information on arsenite localization in the ovular vascular trace (OVT) of rice grains. These results demonstrate that inorganic As is poorly remobilized, while organic species are readily remobilized, from leaves to grain. Stem translocation of inorganic As may not rely solely on silicic acid transporters.

  10. Programming A Molecular Relay for Ultrasensitive Biodetection through 129 Xe NMR

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yanfei [Department of Chemistry, University of Pennsylvania, 231 South 34th Street Philadelphia PA 19104-6323 USA; Roose, Benjamin W. [Department of Chemistry, University of Pennsylvania, 231 South 34th Street Philadelphia PA 19104-6323 USA; Philbin, John P. [Department of Chemistry, University of Pennsylvania, 231 South 34th Street Philadelphia PA 19104-6323 USA; Doman, Jordan L. [Department of Chemistry, University of Pennsylvania, 231 South 34th Street Philadelphia PA 19104-6323 USA; Dmochowski, Ivan J. [Department of Chemistry, University of Pennsylvania, 231 South 34th Street Philadelphia PA 19104-6323 USA

    2015-12-21

    We reported a supramolecular strategy for detecting specific proteins in complex media by using hyperpolarized 129Xe NMR. A cucurbit[6]uril (CB[6])-based molecular relay was programmed for three sequential equilibrium conditions by designing a two-faced guest (TFG) that initially binds CB[6] and blocks the CB[6]–Xe interaction. Moreover, the protein analyte recruits the TFG and frees CB[6] for Xe binding. TFGs containing CB[6]- and carbonic anhydrase II (CAII)-binding domains were synthesized in one or two steps. X-ray crystallography confirmed TFG binding to Zn2+ in the deep CAII active-site cleft, which precludes simultaneous CB[6] binding. The molecular relay was reprogrammed to detect avidin by using a different TFG. Finally, Xe binding by CB[6] was detected in buffer and in E. coli cultures expressing CAII through ultrasensitive 129Xe NMR spectroscopy.

  11. XeCl Excimer Laser For Micro - Machining Of Materials: Preliminary Theoretical And Experimental Works.

    Science.gov (United States)

    Iwanejko, Leszek; Pokora, Ludwik; Stefanski, Miroslaw; Ujda, Zbigniew

    1987-10-01

    The paper presents the results of preliminary investigations, both theoretical and experimental, of XeC1 excimer laser pumped by transverse electric discharge with UU preionization. The medium was a mixture of gases He-Xe-HC1. A theoretical model of the XeC1 laser was worked out and a lot of laser parameters calculations were done. In the same time an excimer laser operating on the mixture He-Xe-HC1 was started, the generation of laser radiation was of energy about 20mJ.

  12. 21 CFR 520.2100 - Selenium, vitamin E capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Selenium, vitamin E capsules. 520.2100 Section 520... to 1 milligram of selenium) and 56.2 milligrams of vitamin E (68 I.U.) (as d-alpha tocopheryl acid... of vitamin E (17 I.U.) (as d-alpha tocopheryl acid succinate.) (b) Sponsor. See No. 000061 in § 510...

  13. Gain measurements of the Ca-Xe charge exchange system. [for UV lasers

    Science.gov (United States)

    Michels, C. J.; Chubb, D. L.

    1978-01-01

    Charge-exchange-pumped Ca(+) was studied for possible positive laser gain at 370.6 and 315.9 nm using an Xe MPD arc as the Xe(+) source. The present paper describes the MPD arc, the calcium injection system, the diagnostics for gain, and spontaneous emission measurements and results. No positive gain measurements were observed. A small Xe-Ca charge exchange cross section compared to He-metal laser systems charge exchange cross sections is the most probable reason why the result was negative.

  14. NGDC/WDS Global Historical Tsunami Database, 2100 BC to present

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Global Historical Tsunami Database provides information on over 2,400 tsunamis from 2100 BC to the present in the the Atlantic, Indian, and Pacific Oceans; and...

  15. Field evidence of social influence in the expression of political preferences: the case of secessionists flags in Barcelona.

    Science.gov (United States)

    Parravano, Antonio; Noguera, José A; Hermida, Paula; Tena-Sánchez, Jordi

    2015-01-01

    Models of social influence have explored the dynamics of social contagion, imitation, and diffusion of different types of traits, opinions, and conducts. However, few behavioral data indicating social influence dynamics have been obtained from direct observation in "natural" social contexts. The present research provides that kind of evidence in the case of the public expression of political preferences in the city of Barcelona, where thousands of citizens supporting the secession of Catalonia from Spain have placed a Catalan flag in their balconies and windows. Here we present two different studies. 1) During July 2013 we registered the number of flags in 26% of the electoral districts in the city of Barcelona. We find that there is a large dispersion in the density of flags in districts with similar density of pro-independence voters. However, by comparing the moving average to the global mean we find that the density of flags tends to be fostered in electoral districts where there is a clear majority of pro-independence vote, while it is inhibited in the opposite cases. We also show that the distribution of flags in the observed districts deviates significantly from that of an equivalent random distribution. 2) During 17 days around Catalonia's 2013 national holiday we observed the position at balcony resolution of the flags displayed in the facades of a sub-sample of 82 blocks. We compare the 'clustering index' of flags on the facades observed each day to thousands of equivalent random distributions. Again we provide evidence that successive hangings of flags are not independent events but that a local influence mechanism is favoring their clustering. We also find that except for the national holiday day the density of flags tends to be fostered in facades located in electoral districts where there is a clear majority of pro-independence vote.

  16. The epidemiology of injuries in contact flag football.

    Science.gov (United States)

    Kaplan, Yonatan; Myklebust, Grethe; Nyska, Meir; Palmanovich, Ezequiel; Victor, Jan; Witvrouw, Erik

    2013-01-01

    To characterize the epidemiology of injuries in post-high school male and female athletes in the rapidly growing international sport of contact flag football. Prospective injury-observational study. Kraft Stadium, Jerusalem, Israel. A total of 1492 players, consisting of men (n = 1252, mean age, 20.49 ± 5.11) and women (n = 240, mean age, 21.32 ± 8.95 years), participated in 1028 games over a 2-season period (2007-2009). All time-loss injuries sustained in game sessions were recorded by the off-the-field medical personnel and followed up by a more detailed phone injury surveillance questionnaire. One hundred sixty-three injuries were reported, comprising 1 533 776 athletic exposures (AEs). The incidence rate was 0.11 [95% confidence interval (CI), 0.09-0.12] per 1000 AEs, and incidence proportion was 10.66% (95% CI, 9.10-12.22). Seventy-six percent of the injuries were extrinsic in nature. Thirty percent of the injuries were to the fingers, thumb, and wrist, 17% to the knee, 17% to the head/face, 13% to the ankle, and 11% to the shoulder. Contact flag football results in a significant amount of moderate to severe injuries. These data may be used in the development of a formal American flag football injury database and in the development and implementation of a high-quality, randomized, prospective injury prevention study. This study should include the enforcement of the no-pocket rule, appropriate headgear, self-fitting mouth guards, the use of ankle braces, and changing the blocking rules of the game.

  17. New study on the XeVIII spectrum

    International Nuclear Information System (INIS)

    Gallardo, M.; Raineri, M.; Giuliani, M.; Lagorio, C.; Padilla, S.; Sarmiento, R.; Reyna Almandos, J.G.

    2005-01-01

    Capillary light sources were used to observe the spectrum of seven-times-ionized xenon, XeVIII, in the 300-6000 A wavelength range. Twenty-eight energy levels belonging to the 5s-9s, 5d-9d, 5g-9g, 7i-10i, 9l, 5p-9p, 4f-9f, 6h-9h and 8k-10k configurations were adjusted and 38 new spectral lines were classified. The XeVIII ionization energy was determined with improved accuracy using the polarization model. The analysis was supported by Hartree-Fock calculations. The weighted oscillator strengths for all the observed spectral lines were also calculated considering the fitted values for the energy parameters

  18. New study on the XeVIII spectrum

    Energy Technology Data Exchange (ETDEWEB)

    Gallardo, M. [Centro de Investigaciones Opticas (CIOp) Casilla de Correo 124, 1900 La Plata (Argentina)]. E-mail: gallardom@ciop.unlp.edu.ar; Raineri, M. [Centro de Investigaciones Opticas (CIOp) Casilla de Correo 124, 1900 La Plata (Argentina)]. E-mail: monicar@ciop.unlp.edu.ar; Giuliani, M. [Dto. de Fisica, Fac. de C. Exactas y Naturales, Universidad Nacional de Mar del Plata Funes 3350 (7600) Mar del Plata (Argentina); Lagorio, C. [Dto. de Fisica, Fac. de C. Exactas y Naturales, Universidad Nacional de Mar del Plata Funes 3350 (7600) Mar del Plata (Argentina); Padilla, S. [Dto. de Fisica, Fac. de C. Exactas y Naturales, Universidad Nacional de Mar del Plata Funes 3350 (7600) Mar del Plata (Argentina); Sarmiento, R. [Dto. De Fisica, Universidad del Atlantico, A.A 1890 Barranquilla (Colombia); Reyna Almandos, J.G. [Centro de Investigaciones Opticas (CIOp) Casilla de Correo 124, 1900 La Plata (Argentina)]. E-mail: jreyna@ciop.unlp.edu.ar

    2005-10-15

    Capillary light sources were used to observe the spectrum of seven-times-ionized xenon, XeVIII, in the 300-6000 A wavelength range. Twenty-eight energy levels belonging to the 5s-9s, 5d-9d, 5g-9g, 7i-10i, 9l, 5p-9p, 4f-9f, 6h-9h and 8k-10k configurations were adjusted and 38 new spectral lines were classified. The XeVIII ionization energy was determined with improved accuracy using the polarization model. The analysis was supported by Hartree-Fock calculations. The weighted oscillator strengths for all the observed spectral lines were also calculated considering the fitted values for the energy parameters.

  19. Search for the permanent electric dipole moment of 129Xe

    Science.gov (United States)

    Sachdeva, Natasha; Chupp, Timothy; Gong, Fei; Babcock, Earl; Salhi, Zahir; Burghoff, Martin; Fan, Isaac; Killian, Wolfgang; Knappe-Grüneberg, Silvia; Schabel, Allard; Seifert, Frank; Trahms, Lutz; Voigt, Jens; Degenkolb, Skyler; Fierlinger, Peter; Krägeloh, Eva; Lins, Tobias; Marino, Michael; Meinel, Jonas; Niessen, Benjamin; Stuiber, Stefan; Terrano, William; Kuchler, Florian; Singh, Jaideep

    2017-09-01

    CP-violation in Beyond-the-Standard-Model physics, necessary to explain the baryon asymmetry, gives rise to permanent electric dipole moments (EDMs). EDM measurements of the neutron, electron, paramagnetic and diamagnetic atoms constrain CP-violating parameters. The current limit for the 129Xe EDM is 6 ×10-27 e . cm (95 % CL). The HeXeEDM experiment at FRM-II (Munich Research Reactor) and BMSR-2 (Berlin Magnetically Shielded Room) uses a stable magnetic field in a magnetically shielded room and 3He comagnetometer with potential to improve the limit by two orders of magnitude. Polarized 3He and 129Xe free precession is detected with SQUID magnetometers in the presence of applied electric and magnetic fields. Conclusions from recent measurements will be presented.

  20. Measurement of
 the azimuthal anisotropy of charged particles 
in 5.02 TeV Pb+Pb and 5.44 TeV Xe+Xe collisions 
with ATLAS

    CERN Document Server

    Bold, Tomasz; The ATLAS collaboration

    2018-01-01

    The experimental data collected by the ATLAS experiment during the 2015 Pb+Pb and 2017 Xe+Xe LHC runs offer new opportunities to study charged particle azimuthal anisotropy. The high-statistics Pb+Pb sample allows for a detailed study of the azimuthal anisotropy of produced particles. This should improve the understanding of initial conditions of nuclear collisions, hydrodynamical behavior of quark-gluon plasma and parton energy loss. New ATLAS measurements of differential and global Fourier harmonics of charged particles (vn) in 5.02 TeV Pb+Pb and 5.44 TeV Xe+Xe collisions in a wide range of transverse momenta, pseudorapidity (|η|<2.5) and collision centrality are presented. The higher order harmonics, sensitive to fluctuations in the initial state, are measured up to n=7 using the two-particle correlation, cumulant and scalar product methods. The dynamic properties of QGP are studied using a recently-proposed modified Pearson's correlation coefficient, ρ(v2n,pT), between the eventwise mean transverse m...

  1. Laser generation of XeCl exciplex molecules in a longitudinal repetitively pulsed discharge in a Xe - CsCl mixture

    Science.gov (United States)

    Boichenko, A. M.; Klenovskii, M. S.

    2015-12-01

    By using the previously developed kinetic model, we have carried out simulations to study the possibility of laser generation of XeCl exciplex molecules in the working medium based on a mixture of Xe with CsCl vapours, excited by a longitudinal repetitively pulsed discharge. The formation mechanism of exciplex molecules in this mixture is fundamentally different from the formation mechanisms in the traditional mixtures of exciplex lasers. The conditions that make the laser generation possible are discussed. For these conditions, with allowance for available specific experimental conditions of the repetitively pulsed discharge excitation, we have obtained the calculated dependences of the power and efficiency of generation on the reflectivity of mirrors in a laser cavity.

  2. Magnetic dipole strength in {sup 128}Xe and {sup 134}Xe in the spin-flip resonance region

    Energy Technology Data Exchange (ETDEWEB)

    Massarczyk, R. [Helmholtz-Zentrum Dresden-Rossendorf, 01328 Dresden (Germany); Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Rusev, G. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Schwengner, R.; Doenau, F. [Helmholtz-Zentrum Dresden-Rossendorf, 01328 Dresden (Germany); Bathia, C. [McMaster University, Hamilton, Ontario L8S4L8 (Canada); Gooden, M.E.; Kelley, J.H. [Triangle Universities Nuclear Laboratory, Durham, NC 27708 (United States); North Carolina State University, Raleigh, NC 27695 (United States); Tonchev, A.P. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Tornow, W. [Triangle Universities Nuclear Laboratory, Durham, NC 27708 (United States); Duke University, Durham, NC 27708 (United States)

    2015-07-01

    The magnetic dipole strength in the energy region of the spin-flip resonance is investigated in {sup 128}Xe and {sup 134}Xe using quasimonoenergetic and linearly polarized γ-ray beams at the High-Intensity γ-Ray Source facility in Durham, North Carolina, USA. Absorption cross sections were deduced for the magnetic and electric and dipole strength distributions separately for various intervals of excitation energy, including the strength of states in the unresolved quasicontinuum. The magnetic dipole strength distributions show structures resembling a resonance in the spin-flip region around an excitation energy of 8 MeV. The electric dipole strength distributions obtained from the present experiments are in agreement with the ones deduced from an earlier experiment using broad-band bremsstrahlung instead of a quasimonoenergetic beam. The experimental magnetic and electric dipole strength distributions are compared with model predictions.

  3. Highlights in radiation measuring technique's - Serial Micro Channel SMC 2100

    International Nuclear Information System (INIS)

    Kandler, M.; Hoffmann, Ch.

    2002-01-01

    The Serial Micro Channel SMC 2100 offers an ''intelligent stand alone'' electronics for the radiation measuring technique's. First it is designed of being connected to a serial interface RS232 of a PC. With a RS485 serial interface on a PC, a network structure can be generated. It has all functional modules which are necessary for the measurement of detector signals. Hence it is possible to directly connect any detector for radiation measurement to a PC, laptop, or notebook. All variations can be operated without PC support too. It has a modular structure and consists of two blocks, the functional modules and the basic modules. The Serial Micro Channel SMC 2100 may be directly coupled to a detector, which therefore makes the realisation of an ''intelligent radiation detector'' with serial link RS232 or RS485. (orig.)

  4. Negative heat capacities in central Xe+Sn reactions

    International Nuclear Information System (INIS)

    Le Neindre, N.; Bougault, R.; Gulminelli, F.

    2000-02-01

    In this study the fluctuation method is applied to the 32-50 A.MeV Xe + Sn central collisions detected with the INDRA multidetector. This method based on kinetic energy fluctuations allows the authors to provide information on the liquid gas phase transition in nuclear multifragmentation. In the case of Xe + Sn central reactions a divergence in the total heat capacity is observed. This divergence corresponds to large fluctuations on the detected fragment partitions. A negative heat capacity branch is measured and so tends to confirm the observation of a first order phase transition in heavy-ion collisions. (A.C.)

  5. Comparison of 133Xe gas dynamic SPECT and thin-section CT in patients with pulmonary emphysema

    International Nuclear Information System (INIS)

    Takahashi, Kazue; Satoh, Katashi; Ohkawa, Motoomi

    2001-01-01

    We assessed 133 Xe gas dynamic single photon emission computed tomography (SPECT) by comparing washout axial images with thin-section CT (TSCT) in patients with pulmonary emphysema. Twenty-three patients were studied. All patients were diagnosed as having pulmonary emphysema on the basis of TSCT. We compared TSCT of upper, middle and lower lung fields with 133 Xe gas dynamic SPECT axial images at the corresponding levels during the 3 to 4 minutes of washout phase. If the degree of 133 Xe gas retention or TSCT finding of ventral and dorsal parts was not the same, the images were divided into two parts. A total of 174 lesions in 23 cases were examined, but 3 lesions having no retention of 133 Xe gas at equilibrium phase were excluded. The results showed that: there were 37 lesions (21.6%) with equivalent severity on both images; there were 42 lesions (24.5%) with more severity on 133 Xe gas dynamic SPECT than on TSCT; and there were 92 lesions (53.8%) with more severity on TSCT than on 133 Xe gas dynamic SPECT. The severity on 133 Xe gas dynamic SPECT and TSCT was not always compatible. One of the reasons for the variable 133 Xe gas retention even when the lesion had the same severity on TSCT, may be bronchial stricture which cannot be seen on TSCT. By comparison of axial images of 133 Xe gas dynamic SPECT with CT images, we could recognize the areas of 133 Xe gas retention in detail. Results suggest that 133 Xe gas dynamic SPECT can be useful to identify ventilation impairment in pulmonary emphysema. (author)

  6. Generation and characterization of a human-mouse chimeric high-affinity antibody that detects the DYKDDDDK FLAG peptide.

    Science.gov (United States)

    Ikeda, Koki; Koga, Tomoaki; Sasaki, Fumiyuki; Ueno, Ayumi; Saeki, Kazuko; Okuno, Toshiaki; Yokomizo, Takehiko

    2017-05-13

    DYKDDDDK peptide (FLAG) is a useful tool for investigating the function and localization of proteins whose antibodies (Abs) are not available. We recently established a high-affinity monoclonal antibody (mAb) for FLAG (clone 2H8). The 2H8 Ab is highly sensitive for detecting FLAG-tagged proteins by flowcytometry and immunoprecipitation, but it can yield nonspecific signals in immunohistochemistry of mouse tissues because it is of mouse origin. In this study, we reduced nonspecific signals by generating a chimeric 2H8 Ab with Fc fragments derived from human immunoglobulin. We fused a 5' terminal cDNA fragments for the Fab region of 2H8 mAb with 3' terminal cDNA fragments for Fc region of human IgG1. We transfected both chimeric plasmids and purified the resulting human-mouse chimeric 2H8. The chimeric 2H8 Ab successfully detected FLAG-tagged proteins in flowcytometry with anti-human IgG secondary Ab with comparable sensitivity to 2H8 mAb. Importantly, chimeric 2H8 detected specific FLAG peptide signals without nonspecific signals in immunohistochemical analysis with mouse tissues. This human-mouse chimeric high-affinity anti-FLAG Ab will prove useful for future immunohistochemical analysis of mouse tissues. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Level structure in 123Xe

    International Nuclear Information System (INIS)

    Luukko, A.; Hattula, J.; Helppi, H.; Knuuttila, O.

    1980-09-01

    The level structure of 123 Xe has been studied with 122 Te( 3 He,2n) and 123 Te( 3 He,3n) reactions using in-beam γ-ray spectroscopic methods. Band-like level structures based on the unique-parity hsub(11/2) neutron state and different low-j states are observed. The isomeric state proposed earlier is established at 185.4 keV with a half-life of 5.6+-0.3 μs, and a new spin assignment of 7/2 - is proposed for this level. A triaxial-rotor-model calculation has been performed to interprete the negative-parity level system. Because of the 7/2 - state, we do not obtain a consistent description of the negative-parity states with the triaxial rotor model, unlike the heavier odd-A Xe nuclei. On the other hand, the positive-parity level structures are interpreted in terms of the core-quasiparticle model supposing a vibrational core. This indicates different core shapes for the positive- and negative-parity level systems. (author)

  8. Structure of intruder band in "1"1"9"-"1"2"9Xe

    International Nuclear Information System (INIS)

    Sharma, H.P.; Chakraborty, S.; Tiwary, S.S.

    2017-01-01

    Xe isotopes in A∼130 mass region are known for their variety of structural phenomena, such as, unexpected signature splitting, signature inversion, γ-vibration etc. These phenomena are associated to axialy asymmetric shape. The triaxial shape in Xe nuclei are expected to originate due to the availability of prolate driving low-Ω πh_1_1_/_2 orbital and oblate driving high-Ω νh11/2 orbital near Fermi surface. The observed experimental E (4"+)/E (2"+) value (∼2.5) also support the γ-soft nature of these nuclei. Interestingly, both proton and neutron alignments have been observed in νh_1_1_/_2 band in "1"1"9"-"1"2"5Xe and neutron alignment dominates. In "1"2"9Xe, proton alignment reported to dominate. It is also supported by TPRM calculations, although, there are no significant change in the neutron orbitals. Whether this change in the alignment is occurred at N=75 or 73 is not known. Therefore, it is interesting to understand the status of the neutron and proton alignment in "1"2"7Xe, which are not studied well. Hence, in-beam γ-ray spectroscopy of "1"2"7Xe was carried out using "1"2"2Sn("9Be, 4nγ) fusion-evaporation reaction at 48 MeV using INGA facility at Inter-University Accelerator Centre, New Delhi. Details of the analysis and results will be discussed during the conference. (author)

  9. Theoretical Study of the NMR Chemical Shift of Xe in Supercritical Condition

    DEFF Research Database (Denmark)

    Lacerda Junior, Evanildo Gomes; Sauer, Stephan P. A.; Mikkelsen, Kurt Valentin

    2018-01-01

    In this work we investigate the level of theory necessary for reproducing the non-linear variation of the 129Xe nuclear magnetic resonance (NMR) chemical shift with the density of Xe in supercritical conditions. In detail we study how the 129Xe chemical shift depends under these conditions...... on electron correlation, relativistic and many-body effects. The latter are included using a sequential-QM/MM methodology, in which a classical MD simulation is performed first and the chemical shift is then obtained as an average of quantum calculations of 250 MD snapshots conformations carried out for Xen...... this approach we obtain very good agreement with the experimental data, showing that the chemical shift of 129Xe in supercritical conditions is very well described by cluster calculations at the HF level, with small contributions from relativistic and electron correlation effects....

  10. Biological variation of platelet parameters determined by the Sysmex XN hematology analyzer.

    Science.gov (United States)

    Buoro, Sabrina; Seghezzi, Michela; Manenti, Barbara; Pacioni, Aurelio; Carobene, Anna; Ceriotti, Ferruccio; Ottomano, Cosimo; Lippi, Giuseppe

    2017-07-01

    This study was aimed to define the short- and medium-term biological variation (BV) estimates, the index of individuality and the reference change value (RCV) of platelet count, platelet distribution width, mean platelet volume, platelet larger cell ratio, plateletcrit and immature platelet fraction. The study population consisted of 43 health subjects, who participated to the assessment of medium-term (21 subjects; blood sampling once a week for 5 consecutive weeks) and short-term (22 subjects; blood sampling once a day for 5 consecutive days) BV study, using Sysmex XN-module. Eight subjects were also scheduled to participate to both phases. The data were subject to outlier analysis prior to CV-ANOVA, to determine the BV estimates with the relative confidence intervals. The medium-term and short-term within-subject BV (CV I ) was comprised between 2.3 and 7.0% and 1.1-8.6%, whereas the medium-term and short-term between-subjects BV (CV G ) was comprised between 7.1 and 20.7% and 6.8-48.6%. The index of individuality and index of heterogeneity were always respectively 0.63 for all the parameters, in both arms of the study. The RCVs were similar for all parameters, in both arms of the study. This study allowed to define the BV estimates of many platelet parameters, some of them unavailable in literature. The kinetics of platelet turnover suggests the use of short-term BV data for calculating analytical goals and RCV. The correct clinical interpretation of platelet parameters also necessitates that each laboratory estimates local RCV values. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Targeted Molecular Imaging of Cancer Cells Using MS2-Based 129 Xe NMR

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Keunhong [Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Materials Sciences Division; Netirojjanakul, Chawita [Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Munch, Henrik K. [Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Sun, Jinny [Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Finbloom, Joel A. [Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Wemmer, David E. [Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Physical Biosciences Division; Pines, Alexander [Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Materials Sciences Division; Francis, Matthew B. [Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Materials Sciences Division

    2016-07-25

    Targeted, selective, and highly sensitive 129Xe NMR nanoscale biosensors have been synthesized using a spherical MS2 viral capsid, Cryptophane A molecules, and DNA aptamers. The biosensors showed strong binding specificity toward targeted lymphoma cells (Ramos line). Hyperpolarized 129Xe NMR signal contrast and hyper-CEST 129Xe MRI image contrast indicated its promise as highly sensitive hyperpolarized 129Xe NMR nanoscale biosensor for future applications in cancer detection in vivo.

  12. Equivelar toroids with few flag-orbits

    OpenAIRE

    Collins, José; Montero, Antonio

    2018-01-01

    An $(n+1)$-toroid is a quotient of a tessellation of the $n$-dimensional Euclidean space with a lattice group. Toroids are generalizations of maps in the torus on higher dimensions and also provide examples of abstract polytopes. Equivelar toroids are those that are induced by regular tessellations. In this paper we present a classification of equivelar $(n+1)$-toroids with at most $n$ flag-orbits; in particular, we discuss a classification of $2$-orbit toroids of arbitrary dimension.

  13. Early protection events in swine immunized with an experimental live attenuated classical swine fever marker vaccine, FlagT4G.

    Directory of Open Access Journals (Sweden)

    Lauren G Holinka

    Full Text Available Prophylactic vaccination using live attenuated classical swine fever (CSF vaccines has been a very effective method to control the disease in endemic regions and during outbreaks in previously disease-free areas. These vaccines confer effective protection against the disease at early times post-vaccination although the mechanisms mediating the protection are poorly characterized. Here we present the events occurring after the administration of our in-house developed live attenuated marker vaccine, FlagT4Gv. We previously reported that FlagT4Gv intramuscular (IM administered conferred effective protection against intranasal challenge with virulent CSFV (BICv as early as 7 days post-vaccination. Here we report that FlagT4Gv is able to induce protection against disease as early as three days post-vaccination. Immunohistochemical testing of tissues from FlagT4Gv-inoculated animals showed that tonsils were colonized by the vaccine virus by day 3 post-inoculation. There was a complete absence of BICv in tonsils of FlagT4Gv-inoculated animals which had been intranasal (IN challenged with BICv 3 days after FlagT4Gv infection, confirming that FlagT4Gv inoculation confers sterile immunity. Analysis of systemic levels of 19 different cytokines in vaccinated animals demonstrated an increase of IFN-α three days after FlagT4Gv inoculation compared with mock infected controls.

  14. Experimental ion mobility measurements in Xe-CH4

    Science.gov (United States)

    Perdigoto, J. M. C.; Cortez, A. F. V.; Veenhof, R.; Neves, P. N. B.; Santos, F. P.; Borges, F. I. G. M.; Conde, C. A. N.

    2017-09-01

    Data on ion mobility is important to improve the performance of large volume gaseous detectors. In the present work, the method, experimental setup and results for the ion mobility measurements in Xe-CH4 mixtures are presented. The results for this mixture show the presence of two distinct groups of ions. The nature of the ions depend on the mixture ratio since they are originated by both Xe and CH4. The results here presented were obtained for low reduced electric fields, E/N, 10-25 Td (2.4-6.1 kV ṡ cm-1 ṡ bar-1), at low pressure (8 Torr) (10.6 mbar), and at room temperature.

  15. Laser generation of XeCl exciplex molecules in a longitudinal repetitively pulsed discharge in a Xe – CsCl mixture

    International Nuclear Information System (INIS)

    Boichenko, A M; Klenovskii, M S

    2015-01-01

    By using the previously developed kinetic model, we have carried out simulations to study the possibility of laser generation of XeCl exciplex molecules in the working medium based on a mixture of Xe with CsCl vapours, excited by a longitudinal repetitively pulsed discharge. The formation mechanism of exciplex molecules in this mixture is fundamentally different from the formation mechanisms in the traditional mixtures of exciplex lasers. The conditions that make the laser generation possible are discussed. For these conditions, with allowance for available specific experimental conditions of the repetitively pulsed discharge excitation, we have obtained the calculated dependences of the power and efficiency of generation on the reflectivity of mirrors in a laser cavity. (active media)

  16. Laser generation of XeCl exciplex molecules in a longitudinal repetitively pulsed discharge in a Xe – CsCl mixture

    Energy Technology Data Exchange (ETDEWEB)

    Boichenko, A M [A M Prokhorov General Physics Institute, Russian Academy of Sciences, Moscow (Russian Federation); Klenovskii, M S [National Research Tomsk Polytechnic University, Tomsk (Russian Federation)

    2015-12-31

    By using the previously developed kinetic model, we have carried out simulations to study the possibility of laser generation of XeCl exciplex molecules in the working medium based on a mixture of Xe with CsCl vapours, excited by a longitudinal repetitively pulsed discharge. The formation mechanism of exciplex molecules in this mixture is fundamentally different from the formation mechanisms in the traditional mixtures of exciplex lasers. The conditions that make the laser generation possible are discussed. For these conditions, with allowance for available specific experimental conditions of the repetitively pulsed discharge excitation, we have obtained the calculated dependences of the power and efficiency of generation on the reflectivity of mirrors in a laser cavity. (active media)

  17. And another thing - flags of convenience

    International Nuclear Information System (INIS)

    Flatern, R. von

    2002-01-01

    Crude oil being shipped around the world, when spilled, is a threat to the environment unlike any other commodity, save perhaps for radioactive materials. Therefore, if the oil industry expects to be taken seriously in its role of protecting the environment, it must assume responsibility for its product from wellhead to consumer. Whilst there are many operators paying considerable attention to transportation issues - the largest of them using their own double-hulled tanker fleets - there still too many using ships unsuitable for the purpose, either because of age or the fact that they are single hulled vessels. These derelicts are kept in business by owners who have registered them in country's where inspections are a local joke, registration requires only a fraction of the fee charged by more conscientious nations, and taxes are low. Ships flying flags of convenience have no ties to any country, including the ones in which they are registered. The author says that it is up to the oil industry to clean up their act, for instance they could refuse to use ships that sail under a flag of convenience or single hulled vessels to move their product. The major and large independent companies learned some time ago that taking care of the environment is very much in their interest, and further that only they can do it effectively

  18. Low back pain and physiotherapy use of red flags: the evidence from Scotland.

    Science.gov (United States)

    Ferguson, Fraser; Holdsworth, Lesley; Rafferty, Danny

    2010-12-01

    Red flags are recognised as indicators of possible serious spinal pathology, and their use is indicated by numerous guidelines. Similar to other countries worldwide, Scotland lacked a national view about the overall quality of the physiotherapy management of low back pain and the use of red flags. Anecdotal evidence suggested that practice varied considerably. To improve the use and documentation of red flags by physiotherapists during the assessment and management of low back pain. Prospective, multicentred, national data collection and improvement initiative. National Health Service (NHS) health boards in Scotland (n=14) plus two private provider sites. One hundred and eighty-six individual NHS provider sites and two private provider sites, with in excess of 360 physiotherapists providing services to low back pain patients. Measurement of documented practice in line with evidence- and consensus-based recommendations from guidelines collected via a web-based tool over two 5-week audit cycles interspersed with an improvement phase over 1 year (2008-2009). Data from 2147 patients showed improvement in the documentation of all red flags assessed from 33% (n=709) to 65% (n=1396), and improvement in the documentation of cauda equina syndrome from 60% (n=1288) to 84% (n=1804) over the two cycles. Only two regions provided evidence of 100% documentation of all components of cauda equina syndrome, with wide variation across the country. This national initiative resulted in considerable improvement in the documentation of red flags. Despite this, however, one in five patients did not receive optimal management as recommended by guidance. This has significant implications for patient safety and highlights the need for ongoing education of physiotherapists in this area. Copyright © 2010 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  19. The flagellar protein FLAG1/SMP1 is a candidate for Leishmania-sand fly interaction.

    Science.gov (United States)

    Di-Blasi, Tatiana; Lobo, Amanda R; Nascimento, Luanda M; Córdova-Rojas, Jose L; Pestana, Karen; Marín-Villa, Marcel; Tempone, Antonio J; Telleria, Erich L; Ramalho-Ortigão, Marcelo; McMahon-Pratt, Diane; Traub-Csekö, Yara M

    2015-03-01

    Leishmaniasis is a serious problem that affects mostly poor countries. Various species of Leishmania are the agents of the disease, which take different clinical manifestations. The parasite is transmitted by sandflies, predominantly from the Phlebotomus genus in the Old World and Lutzomyia in the New World. During development in the gut, Leishmania must survive various challenges, which include avoiding being expelled with blood remnants after digestion. It is believed that attachment to the gut epithelium is a necessary step for vector infection, and molecules from parasites and sand flies have been implicated in this attachment. In previous work, monoclonal antibodies were produced against Leishmania. Among these an antibody was obtained against Leishmania braziliensis flagella, which blocked the attachment of Leishmania panamensis flagella to Phlebotomus papatasi guts. The protein recognized by this antibody was identified and named FLAG1, and the complete FLAG1 gene sequence was obtained. This protein was later independently identified as a small, myristoylated protein and called SMP1, so from now on it will be denominated FLAG1/SMP1. The FLAG1/SMP1 gene is expressed in all developmental stages of the parasite, but has higher expression in promastigotes. The anti-FLAG1/SMP1 antibody recognized the flagellum of all Leishmania species tested and generated the expected band by western blots. This antibody was used in attachment and infection blocking experiments. Using the New World vector Lutzomyia longipalpis and Leishmania infantum chagasi, no inhibition of attachment ex vivo or infection in vivo was seen. On the other hand, when the Old World vectors P. papatasi and Leishmania major were used, a significant decrease of both attachment and infection were seen in the presence of the antibody. We propose that FLAG1/SMP1 is involved in the attachment/infection of Leishmania in the strict vector P. papatasi and not the permissive vector L. longipalpis.

  20. Multiple photoionization from 3p excitation of Kr and 4p excitation of Xe

    International Nuclear Information System (INIS)

    Hayaishi, T.

    1986-01-01

    The photoionization cross sections for multiply charged ions produced by 3p excitation of Kr and 4p excitation of Xe have been obtained by means of a time-of-flight mass spectrometer and synchrotron radiation. It is found that the main formation of doubly to quadruply charged ions in both Kr and Xe is caused from the each initial p-hole state through a Coster-Kronig transition followed by Auger of double Auger processes. The formation of singly charged ions in these excitation energy regions is caused by direct photoionization from outermost shell electrons in both Kr and Xe. Triply charged ions are prominently produced among the multiply charged ions. The quadruple photoionization cross sections show clearly the structures due to the Rydberg series, 3p -1 nl of Kr and 4p -1 nl of Xe. Their main structures were assigned to the 3p -1 nd series in Kr and the 4p -1 nd series in Xe. (orig.)

  1. I-Xe dating of aqueous alteration in the CI chondrite Orgueil: I. Magnetite and ferromagnetic separates

    Science.gov (United States)

    Pravdivtseva, O.; Krot, A. N.; Hohenberg, C. M.

    2018-04-01

    The I-Xe system was studied in a ferromagnetic sample separated from the Orgueil CI carbonaceous chondrite with a hand-held magnet and in two magnetite samples, one chemically separated before and the other one after neutron irradiation. This work was done in order to investigate the effects of chemical separation by LiCl and NaOH on the I-Xe system in magnetite. Our test demonstrated that the chemical separation of magnetite before irradiation using either LiCl or NaOH, or both, does not contaminate the sample with iodine and thus cannot lead to erroneous I-Xe ages due to introduction of uncorrelated 128∗Xe. The I-Xe ages of two Orgueil magnetite samples are mutually consistent within experimental uncertainties and, when normalized to an absolute time scale with the reevaluated Shallowater aubrite standard, place the onset of aqueous alteration on the CI parent body at 4564.3 ± 0.3 Ma, 2.9 ± 0.3 Ma after formation of the CV Ca-AI-rich inclusions (CAIs). The I-Xe age of the ferromagnetic Orgueil separate is 3.4 Ma younger, corresponding to a closure of the I-Xe system at 4560.9 ± 0.2 Ma. These and previously published I-Xe data for Orgueil (Hohenberg et al., 2000) indicate that aqueous alteration on the CI parent body lasted for at least 5 Ma. Although the two magnetite samples gave indistinguishable I-Xe ages, their temperature release profiles differed. One of the two Orgueil magnetites released less radiogenic Xe than the other, 80% of it corresponding to the low-temperature peak of the release profile, compared to only 6% in case of the second Orgueil magnetite sample. This could be due to the difference in iodine trapping efficiencies for magnetite grains of different morphologies. Alternatively, the magnetite grains with the lower radiogenic Xe concentrations may have formed at a later stage of alteration when iodine in an aqueous solution was depleted.

  2. 48 CFR 47.403-1 - Availability and unavailability of U.S.-flag air carrier service.

    Science.gov (United States)

    2010-10-01

    ... farthest interchange point on a usually traveled route. (2) When an origin or interchange point is not... interchange point on a usually traveled route to connect with U.S.-flag air carrier service. (3) When a U.S... travel by a foreign-flag air carrier. (e) For travel between two points outside the United States, the...

  3. Multiperturber effects in the Faraday spectrum of Rb atoms immersed in a high-density Xe gas

    Science.gov (United States)

    Woerdman, J. P.; Blok, F. J.; Kristensen, M.; Schrama, C. A.

    1996-02-01

    We have measured the D1 and D2 Faraday spectrum and absorption spectrum of Rb atoms immersed in high-density Xe buffer gas in the range nXe=0.8-4.5×1020 cm-3. We find that the shape of the Faraday spectrum obeys the Becquerel relation over this whole density range; however the relative strength of the Faraday effect compared to absorption changes rather abruptly near nXe=1×1020 cm-3. This is ascribed to the onset of a many-body nature (overlapping collisions) of the Rb:Xe line broadening; the number of perturbers within the Weisskopf sphere is unity at nXe~1×1020 cm-3.

  4. A method for determining leakage of 133Xe gas from septum-sealed glass vials

    International Nuclear Information System (INIS)

    McAllister, J.R.; Borak, T.B.; Pellicciarini, D.W.

    2000-01-01

    The authors have developed a method for determining the leakage of 133 Xe gas from septum-sealed glass vials that are supplied for medical examinations. Twenty vials each originally containing 370 MPq of 133 Xe and 20 vials each originally containing 740 MBq 133 Xe were measured daily for 26 d. Retention of 133 Xe within the vial was modeled as a first order process with a constant rate coefficient, λ T . The value of λ T was estimated for each vial using a regression analysis. The leakage rate, λ L , was then determined assuming that λ L = λ L + λ r where λ r represents the physical decay of 133 Xe. Monte Carlo simulations were performed using uncertainties in the estimates of each vial to obtain the mean and tails of the distribution for the average leakage rate, bar λ L . the average leakage rate for the complete sample of vials was 0.00007 d -1 with an upper, one-sided, 95% confidence limit of 0.0011 d -1 . Uncertainties in the published values of λ r for 133 Xe made a significant contribution to the uncertainties of the leakage rate for this sample of vials. The methods described can be applied to other situations where leakage of radioactive materials may be of concern

  5. FLAG-tagged CD19-specific CAR-T cells eliminate CD19-bearing solid tumor cells in vitro and in vivo.

    Science.gov (United States)

    Berahovich, Robert; Xu, Shirley; Zhou, Hua; Harto, Hizkia; Xu, Qumiao; Garcia, Andres; Liu, Fenyong; Golubovskaya, Vita M; Wu, Lijun

    2017-06-01

    Autologous T cells expressing chimeric antigen receptors (CARs) specific for CD19 have demonstrated remarkable efficacy as therapeutics for B cell malignancies. In the present study, we generated FLAG-tagged CD19-specific CAR-T cells (CD19-FLAG) and compared them to their non-tagged counterparts for their effects on solid and hematological cancer cells in vitro and in vivo . For solid tumors, we used HeLa cervical carcinoma cells engineered to overexpress CD19 (HeLa-CD19), and for hematological cancer we used Raji Burkitt's lymphoma cells, which endogenously express CD19. Like non-tagged CD19 CAR-T cells, CD19-FLAG CAR-T cells expanded in culture >100-fold and exhibited potent cytolytic activity against both HeLa-CD19 and Raji cells in vitro . CD19-FLAG CAR-T cells also secreted significantly more IFN-gamma and IL-2 than the control T cells. In vivo , CD19-FLAG CAR-T cells significantly blocked the growth of HeLa-CD19 solid tumors, increased tumor cleaved caspase-3 levels, and expanded systemically. CD19-FLAG CAR-T cells also significantly reduced Raji tumor burden and extended mouse survival. These results demonstrate the strong efficacy of FLAG-tagged CD19 CAR-T cells in solid and hematological cancer models.

  6. A comparison between the irradiation damage response of spinel and zirconia due to Xe ion bombardment

    International Nuclear Information System (INIS)

    Sickafus, K.E.; Wetteland, C.J.; Baker, N.P.; Yu Ning; Devanathan, R.; Nastasi, M.; Bordes, N.

    1998-01-01

    The mechanical properties of Xe-implanted spinel and cubic zirconia surfaces, as determined by nano-indentation measurements, are distinct and the differences can be related to their microstructures. Upon Xe 2+ ion irradiation to high dose at cryogenic temperature (120 K), the Young's modulus of irradiated spinel falls dramatically until the modulus is only about 3/4 the un-irradiated value. The maximum modulus occurs concurrent with the formation of a metastable crystalline phase of spinel. The subsequent elastic softening at higher Xe 2+ doses is an indication of the onset of amorphization of the spinel. Xe-implanted zirconia surfaces behave differently, in all cases showing almost no change in elastic modulus with increasing Xe 2+ ion dose. This is consistent with microstructural observations of Xe-implanted zirconia crystals which, unlike spinel, show no change in crystal structure with increasing ion dose. The hardness of both spinel and zirconia increases slightly for low Xe 2+ ion doses. At higher doses, zirconia shows little change in hardness, while the hardness of the implanted spinel falls by more than a factor of two. The initial increase in hardness of both spinel and zirconia is consistent with point defect accumulation and the precipitation of small interstitial clusters, while the drop in hardness of spinel at high Xe 2+ ion doses is due to the formation of an amorphous phase. (orig.)

  7. Discovering "The Italian Flag" by Fernando Melani (1907-1985).

    Science.gov (United States)

    Carlesi, Serena; Bartolozzi, Giovanni; Cucci, Costanza; Marchiafava, Veronica; Picollo, Marcello; La Nasa, Jacopo; Di Girolamo, Francesca; Dilillo, Marialaura; Modugno, Francesca; Degano, Ilaria; Colombini, Maria Perla; Legnaioli, Stefano; Lorenzetti, Giulia; Palleschi, Vincenzo

    2016-11-05

    In the occasion of the celebrations for the 150th anniversary of the founding of Italy (1861-2011), it was decided to analyse the artwork "The Italian Flag" (La Bandiera Italiana) created by the artist Fernando Melani (Pistoia, 1907-1985), one of the precursors of the Poor Art artistic movement in Italy. This project is a follow-up to a previous study which was mainly focused on the pigments and dyes found in his home-studio. The main goal of this paper is to identify a correct diagnostic plan, based on the use of a combination of non-invasive and micro-invasive methodologies, in order to determine the state of preservation and define the best conservation procedures for a contemporary artwork. Visible, infrared and infrared false colour images as well as the Fibre Optic Reflectance Spectroscopy (FORS) technique were applied in situ to analyse The Italian Flag. Laser Induced Breakdown Spectroscopy (LIBS), Fourier Transform Infrared (FT-IR) and micro-Raman spectroscopies, Pyrolysis-Gas Chromatography/Mass Spectroscopy (Py-GC/MS), High Performance Liquid Chromatography with Diode Arrays Detection (HPLC-DAD) and Mass Spectrometric Detection (HPLC-ESI-Q-ToF) were all applied to three small samples detached from the three painted (green-blue, white and red-yellow, respectively) areas of the flag. The combination of the data obtained with all these techniques made possible a comprehensive understanding of both the chemical composition and physical behaviour of the materials used by the artist and supported curators in defining the preventive conservation of this artwork. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Discovering "The Italian Flag" by Fernando Melani (1907-1985)

    Science.gov (United States)

    Carlesi, Serena; Bartolozzi, Giovanni; Cucci, Costanza; Marchiafava, Veronica; Picollo, Marcello; La Nasa, Jacopo; Di Girolamo, Francesca; Dilillo, Marialaura; Modugno, Francesca; Degano, Ilaria; Colombini, Maria Perla; Legnaioli, Stefano; Lorenzetti, Giulia; Palleschi, Vincenzo

    2016-11-01

    In the occasion of the celebrations for the 150th anniversary of the founding of Italy (1861-2011), it was decided to analyse the artwork ;The Italian Flag; (La Bandiera Italiana) created by the artist Fernando Melani (Pistoia, 1907-1985), one of the precursors of the Poor Art artistic movement in Italy. This project is a follow-up to a previous study which was mainly focused on the pigments and dyes found in his home-studio. The main goal of this paper is to identify a correct diagnostic plan, based on the use of a combination of non-invasive and micro-invasive methodologies, in order to determine the state of preservation and define the best conservation procedures for a contemporary artwork. Visible, infrared and infrared false colour images as well as the Fibre Optic Reflectance Spectroscopy (FORS) technique were applied in situ to analyse The Italian Flag. Laser Induced Breakdown Spectroscopy (LIBS), Fourier Transform Infrared (FT-IR) and micro-Raman spectroscopies, Pyrolysis-Gas Chromatography/Mass Spectroscopy (Py-GC/MS), High Performance Liquid Chromatography with Diode Arrays Detection (HPLC-DAD) and Mass Spectrometric Detection (HPLC-ESI-Q-ToF) were all applied to three small samples detached from the three painted (green-blue, white and red-yellow, respectively) areas of the flag. The combination of the data obtained with all these techniques made possible a comprehensive understanding of both the chemical composition and physical behaviour of the materials used by the artist and supported curators in defining the preventive conservation of this artwork.

  9. Resistivity and morphology of TiSi2 formed on Xe+-implanted polycrystalline silicon

    International Nuclear Information System (INIS)

    Kuwano, H.; Phillips, J.R.; Mayer, J.W.

    1990-01-01

    Xe ion irradiation of polycrystalline silicon before Ti deposition is found to affect subsequent silicide formation. Silicide films were prepared by implanting 60, 100, or 240 keV Xe + ions into 500-nm-thick undoped polycrystalline silicon before depositing Ti and annealing in vacuum. Preimplantation altered the subsequent silicide resistivity, x-ray diffraction patterns, and morphology as compared to films prepared on unimplanted polycrystalline Si substrates. We found that minimal TiSi 2 resistivities were achieved at lower temperatures with preimplantation, indicating that the Xe-implanted substrate promotes a lower temperature transition from the metastable C49 phase to the low-resistivity equilibrium C54 phase of TiSi 2 . X-ray diffraction results confirmed the lower temperature formation of the C54 phase with preimplantation. Low-temperature annealing (650 degree C, 30 min) of 6x10 16 cm -2 , 240 keV Xe + -implanted samples yielded low-resistivity (∼22 μΩ cm) silicide films, while simultaneously annealed samples without preimplantation had resistivity five times higher. Lower doses were effective at lower implant energies, with low resistivity achieved after 725 degree C, 30 min annealing for 2x10 15 cm -2 , 60 keV Xe + preimplantation

  10. Xe-133 recuperation by adsorption in active carbon impregnated with PF5

    International Nuclear Information System (INIS)

    Mondino, A.V.; Marques, R.O.

    1990-01-01

    Since the Mo-99 Fission Project has the aim to produce Xe-133 from gases generated in the alkaline dissolution of Al-U plates irradiated with thermal neutrons and, considering the importance of this radioisotope from the nuclear medicine point of view, studies to improve and optimize the Xe-133 recuperation were continued. Experiences were made on 'static' equilibrium employing high purity xenon and for the 'dynamic' case, Xe-133 mixed with a carrier and nitrogen as gas carrier; in this case, a 44% and a 34% increase in the capacity of xenon adsorption relaxed with activated carbon without being impregnated and impregnated with AgF, were respectively achieved. (Author) [es

  11. Estuary 2100 Project, Phase 1: Resilient Watersheds for a Changing Climate

    Science.gov (United States)

    Information about the SFBWQP Estuary 2100 Project, Phase 1: Resilient Watersheds for a Changing Climate , part of an EPA competitive grant program to improve SF Bay water quality focused on restoring impaired waters and enhancing aquatic resources.

  12. Exploring new Xe-129 chemical shift ranges in HXeY compounds: hydrogen more relativistic than xenon

    Czech Academy of Sciences Publication Activity Database

    Lantto, P.; Standara, Stanislav; Riedel, S.; Vaara, J.; Straka, Michal

    2012-01-01

    Roč. 14, č. 31 (2012), s. 10944-10952 ISSN 1463-9076 R&D Projects: GA ČR GA203/09/2037 Grant - others:GA MŠk(CZ) LM2010005; 7th European Framework Program(XE) 230955; CEITEC(XE) CZ.1.05/1.1.00/02.0068 Institutional research plan: CEZ:AV0Z40550506 Keywords : 129Xe NMR * novel Xe compounds * relativistic effects * rare-gas * ab-initio * NMR properties Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 3.829, year: 2012

  13. Fluid-structure-interaction of a flag in a channel flow

    Science.gov (United States)

    Liu, Yingzheng; Yu, Yuelong; Zhou, Wenwu; Wang, Weizhe

    2017-11-01

    The unsteady flow field and flapping dynamics of an inverted flag in water channel are investigated using time resolved particle image velocimetry (TR-PIV) measurements. The dynamically deformed profiles of the inverted flag are determined by a novel algorithm that combines morphological image processing and principle component analysis. Instantaneous flow field, phase averaged vorticity, time-mean flow field and turbulent kinematic energy are addressed for the flow. Four modes are discovered as the dimensionless bending stiffness decreases, i.e., the straight mode, the biased mode, the flapping mode and the deflected mode. Among all modes, the flapping mode is characterized by large flapping amplitude and the reverse von Kármán vortex street wake, which is potential to enhance heat transfer remarkably. National Natural Science Foundation of China.

  14. Experimental ion mobility measurements in Xe-C2H6

    Science.gov (United States)

    Perdigoto, J. M. C.; Cortez, A. F. V.; Veenhof, R.; Neves, P. N. B.; Santos, F. P.; Borges, F. I. G. M.; Conde, C. A. N.

    2017-10-01

    In this paper we present the results of the ion mobility measurements made in gaseous mixtures of xenon (Xe) with ethane (C2H6) for pressures ranging from 6 to 10 Torr (8-10.6 mbar) and for low reduced electric fields in the 10 Td to 25 Td range (2.4-6.1 kVṡcm-1ṡ bar-1), at room temperature. The time of arrival spectra revealed two peaks throughout the entire range studied which were attributed to ion species with 3-carbons (C3H5+, C3H6+ C3H8+ and C3H9+) and with 4-carbons (C4H7+, C4H9+ and C4H10+). Besides these, and for Xe concentrations above 70%, a bump starts to appear at the right side of the main peak for reduced electric fields higher than 20 Td, which was attributed to the resonant charge transfer of C2H6+ to C2H6 that affects the mobility of its ion products (C3H8+ and C3H9+). The time of arrival spectra for Xe concentrations of 20%, 50%, 70% and 90% are presented, together with the reduced mobilities as a function of the Xe concentration calculated from the peaks observed for the low reduced electric fields and pressures studied.

  15. Bioenergetic Consequences of FLAG Tag Addition to the C-Terminus of Subunit 8 of Yeast Saccharomyces cerevisiae Mitochondrial ATP Synthase

    Directory of Open Access Journals (Sweden)

    I MADE ARTIKA

    2010-09-01

    Full Text Available The yeast mitochondrial F1F0-ATP synthase is a multisubunit complex that contains at least 17 different subunits. Subunit 8 of yeast mitochondrial ATP synthase is a hydrophobic protein of 48 amino acids encoded by the mitochondrial ATP8 gene. Subunit 8 has three distinct domains; an N-terminal domain, a central hydrophobic domain and a C-terminal domain. FLAG tag addition to subunit 8 protein potentially facilitate elucidation of its topology, structure, and function. It has been shown that following incorporation of FLAG tag to its C-terminus, subunit 8 still assemble into functional ATP synthase complex. In order to analyze bioenergetic consequences of the FLAG tag addition, a yeast strain expressing FLAG tagged-subunit 8 was subjected to cellular respiration assays. Results obtained showed that addition of FLAG tag to the C-terminus of subunit 8 does not impair its proper functioning. The FLAG tag system, therefore, can be employed to study subunit 8′s detailed structure, topology, and function.

  16. Study of the spallation reactions 136Xe + p and 136Xe + 12C at 1 GeV per nucleon at the GSI facility (Darmstadt, Germany)

    International Nuclear Information System (INIS)

    Gorbinet, T.

    2011-11-01

    The collision of 136 Xe with a proton and with 12 C at 1 GeV per nucleon of projectile kinetic energy in the center of mass has been studied in inverse kinematics using the SPALADIN experimental setup at the GSI facility. This manuscript describes the analysis of these collisions realized in spring 2009. The detection in coincidence of the final state fragments (projectile residues, neutrons and light charged fragments) with a large geometrical efficiency is provided by the inverse kinematics combined with a large aperture dipole magnet and large detectors. Such a coincidence, measured on an event basis, allows selecting, in a model independent way, the pre-fragment, the excited nuclear system formed after the intranuclear cascade as a function of its excitation energy. Hence, we were able to study the evolution of the pre-fragment deexcitation mechanism (evaporation of light particles, asymmetric binary decay, multiple fragmentation..) as a function of its excitation energy. The data of the 136 Xe + p reaction have been compared mainly to three deexcitation models (SMM, GEMINI++ and ABLA07) coupled to the intranuclear cascade code INCL4. Despite the relatively good and global agreement between these models and our data, significant discrepancies appeared concerning in particular the production of intermediate mass fragments (IMF). Comparison between the 136 Xe + 12 C and the 136 Xe + p data exhibits an important similarity in the deexcitation of the pre-fragments. This suggests that the nuclear cascade leads, for both targets, to similar pre-fragment types in the range of excitation energy (0 to 4 MeV per nucleon) common to both reactions. Higher excitation energies, reached only in the 136 Xe + 12 C reaction, show a qualitative difference in the deexcitation of the pre-fragment, with much higher multiplicities of IMF per event, increasing with the excitation energy. (author)

  17. Compact 2100 nm laser diode module for next-generation DIRCM

    Science.gov (United States)

    Dvinelis, Edgaras; Greibus, Mindaugas; TrinkÅ«nas, Augustinas; NaujokaitÄ--, Greta; Vizbaras, Augustinas; Vizbaras, Dominykas; Vizbaras, Kristijonas

    2017-10-01

    Compact high-power 2100 nm laser diode module for next-generation directional infrared countermeasure (DIRCM) systems is presented. Next-generation DIRCM systems require compact, light-weight and robust laser modules which could provide intense IR light emission capable of disrupting the tracking sensor of heat-seeking missile. Currently used solid-state and fiber laser solutions for mid-IR band are bulky and heavy making them difficult to implement in smaller form-factor DIRCM systems. Recent development of GaSb laser diode technology greatly improved optical output powers and efficiencies of laser diodes working in 1900 - 2450 nm band [1] while also maintaining very attractive size, weight, power consumption and cost characteristics. 2100 nm laser diode module presented in this work performance is based on high-efficiency broad emitting area GaSb laser diode technology. Each laser diode emitter is able to provide 1 W of CW output optical power with working point efficiency up to 20% at temperature of 20 °C. For output beam collimation custom designed fast-axis collimator and slow-axis collimator lenses were used. These lenses were actively aligned and attached using UV epoxy curing. Total 2 emitters stacked vertically were used in 2100 nm laser diode module. Final optical output power of the module goes up to 2 W at temperature of 20 °C. Total dimensions of the laser diode module are 35 x 25 x 16 mm (L x W x H) with a weight of 28 grams. Finally output beam is bore-sighted to mechanical axes of the module housing allowing for easy integration into next-generation DIRCM systems.

  18. Quantum cohomology of flag manifolds and Toda lattices

    International Nuclear Information System (INIS)

    Givental, A.; Kim, B.

    1995-01-01

    We discuss relations of Vafa's quantum cohomology with Floer's homology theory, introduce equivariant quantum cohomology, formulate some conjectures about its general properties and, on the basis of these conjectures, compute quantum cohomology algebras of the flag manifolds. The answer turns out to coincide with the algebra of regular functions on an invariant lagrangian variety of a Toda lattice. (orig.)

  19. Thermally stimulated exoelectron emission from solid Xe

    International Nuclear Information System (INIS)

    Khyzhniy, I.V.; Grigorashchenko, O.N.; Savchenko, E.V.; Ponomarev, A.N.; Bondybey, V.E.

    2007-01-01

    Thermally-stimulated emission of exoelectrons and photons from solid Xe pre-irradiated by low-energy electrons were studied. A high sensitivity of thermally-stimulated luminescence (TSL) and thermally-stimulated exoelectron emission (TSEE) to sample prehistory was demonstrated. It was shown that electron traps in unannealed samples are characterized by much broader distribution of trap levels in comparison with annealed samples and their concentration exceeds in number that in annealed samples. Both phenomena, TSL and TSEE, were found to be triggered by release of electrons from the same kind of traps. The data obtained suggest a competition between two relaxation channels: charge recombination and electron transport terminated by TSL and TSEE. It was found that TSEE predominates at low temperatures while at higher temperatures TSL prevails. An additional relaxation channel, a photon-stimulated exoelectron emission pre-irradiated solid Xe, was revealed

  20. The partition coefficients of 133Xe between blood and bone

    International Nuclear Information System (INIS)

    Lahtinen, T.; Karjalainen, P.; Vaeaenaenen, A.; Lahtinen, R.; Alhava, E.M.

    1981-01-01

    The partition coefficients of 133 Xe between blood and haematopoietic bone marrow and homogenised bone have been determined in vitro. The partition coefficient lambda 1 corresponding to haematopoietic marrow was 0.95 ml g -1 while that corresponding to homogenised bone was a function of age, lambda 2 = 3.11 + 0.049(age)(ml g -1 ). These data can be used for calculating regional blood flow in healthy human femur by means of a simple 133 Xe radionuclide method. (author)

  1. Which energies for 2100?

    International Nuclear Information System (INIS)

    Bobin, Jean-Louis; Deschamps, Lucien

    2013-01-01

    The authors propose a synthesis of works performed by the Prospective 2100 association on the issue of energy. They comment the strongly increasing energy demand which is related to demographic growth and urbanization, the evolution of energy supply at an always increasing cost, and the needed evolution of the energy mix. They notice that electricity demand increases faster than the global energy demand. They discuss the evolution of solar and wind energy (challenge of energy storage), the development of the industrial sector of electricity production and distribution, and the impacts of political choices on energy sectors. They discuss the possible evolutions of the energy sector which are based either on the improvements of existing technologies, or on the emergence of new technologies on the market. They outline the various environmental, economic and geopolitical constraints, state that they expect a great energy transition during the 21. century, discuss the objectives defined for 2050 in terms of reduction of greenhouse gas emissions, and draw perspectives for the second half of the century

  2. Structure of anti-FLAG M2 Fab domain and its use in the stabilization of engineered membrane proteins

    International Nuclear Information System (INIS)

    Roosild, Tarmo P.; Castronovo, Samantha; Choe, Senyon

    2006-01-01

    The X-ray crystallographic analysis of anti-FLAG M2 Fab is reported and the implications of the structure on FLAG epitope binding are described as a first step in the development of a tool for the structural and biophysical study of membrane proteins. The inherent difficulties of stabilizing detergent-solubilized integral membrane proteins for biophysical or structural analysis demand the development of new methodologies to improve success rates. One proven strategy is the use of antibody fragments to increase the ‘soluble’ portion of any membrane protein, but this approach is limited by the difficulties and expense associated with producing monoclonal antibodies to an appropriate exposed epitope on the target protein. Here, the stabilization of a detergent-solubilized K + channel protein, KvPae, by engineering a FLAG-binding epitope into a known loop region of the protein and creating a complex with Fab fragments from commercially available anti-FLAG M2 monoclonal antibodies is reported. Although well diffracting crystals of the complex have not yet been obtained, during the course of crystallization trials the structure of the anti-FLAG M2 Fab domain was solved to 1.86 Å resolution. This structure, which should aid future structure-determination efforts using this approach by facilitating molecular-replacement phasing, reveals that the binding pocket appears to be specific only for the first four amino acids of the traditional FLAG epitope, namely DYKD. Thus, the use of antibody fragments for improving the stability of target proteins can be rapidly applied to the study of membrane-protein structure by placing the short DKYD motif within a predicted peripheral loop of that protein and utilizing commercially available anti-FLAG M2 antibody fragments

  3. Vortex dynamics and heat transfer behind self-oscillating inverted flags of various lengths in channel flow

    Science.gov (United States)

    Yu, Yuelong; Liu, Yingzheng; Chen, Yujia

    2018-04-01

    The influence of an inverted flag's length-to-channel-width ratio (C* = L/W) on its oscillating behavior in a channel flow and the resultant vortex dynamics and heat transfer are determined experimentally. Three systems with C* values of 0.125, 0.250, and 0.375 were chosen for comparison. The interaction of highly unsteady flow with the inverted flag is measured with time-resolved particle image velocimetry. Variations in the underlying flow physics are discussed in terms of the statistical flow quantities, flag displacement, phase-averaged flow field, and vortex dynamics. The results show that the increase in C* shifts the occurrence of the flapping regime at high dimensionless bending stiffness. With the flag in the flapping region, three distinct vortex dynamics—the von Kármán vortex street, the G mode, and the singular mode—are identified at C* values of 0.375, 0.250, and 0.125, respectively. Finally, the heat transfer enhancement from the self-oscillating inverted flag is measured to serve as complementary information to quantify the cause-and-effect relationship between vortex dynamics and wall heat transfer. The increase in C* strongly promotes wall heat removal because disruption of the boundary layer by the energetic vortices is substantially intensified. Among all systems, wall heat transfer removal is most efficient at the intermediate C* value of 0.250.

  4. Investigation of 124Xe nuclear structure with the 8Pi spectrometer at TRIUMF-ISAC

    Science.gov (United States)

    Radich, Allison; Garrett, P.; Jigmeddorj, B.; Michetti-Wilson, J.; Diaz Varela, A.; Hadinia, B.; Bianco, L.; Wong, J.; Chagnon-Lessard, S.; Dunlop, R.; Finlay, P.; Laffoley, A.; Leach, K. G.; Rand, E.; Sumithrarachchi, C.; Svennson, C. E.; Wood, J. L.; Yates, S. W.; Andreoiu, C.; Starosta, K.; Cross, D.; Garnsworthy, A. B.; Hackman, G.; Ball, G.; Triambak, S.

    2013-10-01

    The 124Xe nucleus has been thought to obey O(6) symmetry but a recent Coulomb excitation study has found that while O(5) may be preserved, O(6) appears to be badly broken. To further characterize the structure of this nucleus, a beta-decay experiment was performed at the TRIUMF-ISAC facility. A beam of radioactive 124Cs at a rate of 9.8 × 107 ions/s was implanted at the center of the 8Pi spectrometer where it underwent β + /EC decay into stable 124Xe. High-statistics gamma-gamma coincidence measurements have been analyzed to add to the level scheme of 124Xe, which has been extended considerably. The high statistics data set has revealed a new decay branch from a 124Cs high-spin isomer as well as several very-weak transitions between low-spin states in 124Xe. Branching ratios and B(E2) transition strengths have been calculated for the updated level scheme. The results will be important in determining collective properties and nuclear structure of the 124Xe.

  5. Searches for Lorentz violation in {sup 3}He/{sup 129}Xe clock comparison experiments

    Energy Technology Data Exchange (ETDEWEB)

    Allmendinger, F. [Universitaet Heidelberg, Physikalisches Institut (Germany); Burghoff, M. [Physikalisch-Technische Bundesanstalt (Germany); Heil, W., E-mail: wheil@uni-mainz.de; Karpuk, S. [Johannes-Gutenberg Universitaet, Institut fuer Physik (Germany); Kilian, W.; Knappe-Grueneberg, S.; Mueller, W. [Physikalisch-Technische Bundesanstalt (Germany); Schmidt, U. [Universitaet Heidelberg, Physikalisches Institut (Germany); Schnabel, A.; Seifert, F. [Physikalisch-Technische Bundesanstalt (Germany); Sobolev, Yu [Johannes-Gutenberg Universitaet, Institut fuer Physik (Germany); Trahms, L. [Physikalisch-Technische Bundesanstalt (Germany); Tullney, K. [Johannes-Gutenberg Universitaet, Institut fuer Physik (Germany)

    2013-03-15

    We discuss the design and performance of a very sensitive low-field magnetometer based on the detection of free spin precession of gaseous, nuclear polarized {sup 3}He or {sup 129}Xe samples with a SQUID as magnetic flux detector. Characteristic spin precession times T{sub 2}{sup Asterisk-Operator} of up to 115 h were measured in low magnetic fields (about 1 {mu}T) and in the regime of motional narrowing. With the detection of the free precession of co-located {sup 3}He/{sup 129}Xe nuclear spins (clock comparison), the device can be used as ultra-sensitive probe for non-magnetic spin interactions, since the magnetic dipole interaction (Zeeman-term) drops out in the weighted frequency difference, i.e., {Delta}{omega} = {omega}{sub He} - {gamma}{sub He}/{gamma}{sub Xe}{center_dot}{omega}{sub Xe}. We report on searches for Lorentz violating signatures by monitoring the Larmor frequencies of co-located {sup 3}He/{sup 129}Xe spin samples as the laboratory reference frame rotates with respect to distant stars (sidereal modulation).

  6. Nuclear spin relaxation due to chemical shift anisotropy of gas-phase 129Xe.

    Science.gov (United States)

    Hanni, Matti; Lantto, Perttu; Vaara, Juha

    2011-08-14

    Nuclear spin relaxation provides detailed dynamical information on molecular systems and materials. Here, first-principles modeling of the chemical shift anisotropy (CSA) relaxation time for the prototypic monoatomic (129)Xe gas is carried out, both complementing and predicting the results of NMR measurements. Our approach is based on molecular dynamics simulations combined with pre-parametrized ab initio binary nuclear shielding tensors, an "NMR force field". By using the Redfield relaxation formalism, the simulated CSA time correlation functions lead to spectral density functions that, for the first time, quantitatively determine the experimental spin-lattice relaxation times T(1). The quality requirements on both the Xe-Xe interaction potential and binary shielding tensor are investigated in the context of CSA T(1). Persistent dimers Xe(2) are found to be responsible for the CSA relaxation mechanism in the low-density limit of the gas, completely in line with the earlier experimental findings.

  7. Solid and liquid 129Xe NMR signals enhanced by spin-exchange optical pumping under flow

    International Nuclear Information System (INIS)

    Zhou Xin; Luo Jun; Sun Xianping; Zeng Xizhi; Liu Maili; Liu Wuyang

    2002-01-01

    Laser-polarized 129 Xe gas was produced by spin-exchange with Cs atom optically pumped with diode laser array in a low field under flow. The nuclear spin polarizations of the solid and liquid 129 Xe frozen from the laser-polarized 129 Xe gas were 2.16% and 1.45% respectively in the SY-80M NMR spectrometer, which corresponded to the enhancements of 6000 and 5000 compared to those without optical pumping under the same conditions. It could provide the base and possibility for quantum computers using laser-enhanced solid and liquid 129 Xe. Polarization loss of transport and state change was also discussed

  8. Atomistic simulations of thermodynamic properties of Xe gas bubbles in U10Mo fuels

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Shenyang, E-mail: shenyang.hu@pnnl.gov; Setyawan, Wahyu; Joshi, Vineet V.; Lavender, Curt A.

    2017-07-15

    Xe gas bubble superlattice formation is observed in irradiated uranium–10 wt% molybdenum (U10Mo) fuels. However, the thermodynamic properties of the bubbles (the relationship among bubble size, equilibrium Xe concentration, and bubble pressure) and the mechanisms of bubble superlattice formation are not well known. In this work, the molecular dynamics (MD) method is used to study these properties and mechanisms. The results provide important inputs for quantitative mesoscale models of gas bubble evolution and fuel performance. In the MD simulations, the embedded-atom method (EAM) potential of U10Mo-Xe [1] is employed. Initial gas bubbles with a low Xe concentration (underpressured) are generated in a body-centered cubic (bcc) U10Mo single crystal. Then Xe atoms are sequentially added into the bubbles one by one, and the evolution of pressure and dislocation emission around the bubbles is analyzed. The relationship between pressure, equilibrium Xe concentration, and radius of the bubbles is established. It was found that an overpressured gas bubble emits partial dislocations with a Burgers vector along the <111> direction and a slip plane of (11-2). Meanwhile, dislocation loop punch out was not observed. The overpressured bubble also induces an anisotropic stress field. A tensile stress was found along <110> directions around the bubble, favoring the nucleation and formation of a face-centered cubic bubble superlattice in bcc U10Mo fuels.

  9. Atomistic simulations of thermodynamic properties of Xe gas bubbles in U10Mo fuels

    Science.gov (United States)

    Hu, Shenyang; Setyawan, Wahyu; Joshi, Vineet V.; Lavender, Curt A.

    2017-07-01

    Xe gas bubble superlattice formation is observed in irradiated uranium-10 wt% molybdenum (U10Mo) fuels. However, the thermodynamic properties of the bubbles (the relationship among bubble size, equilibrium Xe concentration, and bubble pressure) and the mechanisms of bubble superlattice formation are not well known. In this work, the molecular dynamics (MD) method is used to study these properties and mechanisms. The results provide important inputs for quantitative mesoscale models of gas bubble evolution and fuel performance. In the MD simulations, the embedded-atom method (EAM) potential of U10Mo-Xe [1] is employed. Initial gas bubbles with a low Xe concentration (underpressured) are generated in a body-centered cubic (bcc) U10Mo single crystal. Then Xe atoms are sequentially added into the bubbles one by one, and the evolution of pressure and dislocation emission around the bubbles is analyzed. The relationship between pressure, equilibrium Xe concentration, and radius of the bubbles is established. It was found that an overpressured gas bubble emits partial dislocations with a Burgers vector along the direction and a slip plane of (11-2). Meanwhile, dislocation loop punch out was not observed. The overpressured bubble also induces an anisotropic stress field. A tensile stress was found along directions around the bubble, favoring the nucleation and formation of a face-centered cubic bubble superlattice in bcc U10Mo fuels.

  10. 46 CFR 153.9 - Foreign flag vessel endorsement application.

    Science.gov (United States)

    2010-10-01

    ... or electronic format, to Commanding Officer, U.S. Coast Guard Marine Safety Center, 2100 2nd St. SW... information submitted under this part must be in English except IMO Certificates which may be in French. [CGD...

  11. THE STATE PRESIDENT'S FLAG SINCE 4 SEPTEMBER 1984

    African Journals Online (AJOL)

    The heraldic description of the flag reads as follows: a rectangular tricolour, ratio three by two, with three triangular fields (top to bottom) in orange, white and blue. The white charged in the hoist with the coat of arms of the Republic of. South Africa. Above the coat of arms the letter. 'SP' are ensigned in gold with black ...

  12. He 3 -Xe 129 Comagnetometery using Rb 87 Detection and Decoupling

    Science.gov (United States)

    Limes, M. E.; Sheng, D.; Romalis, M. V.

    2018-01-01

    We describe a He 3 -Xe 129 comagnetometer using Rb 87 atoms for noble-gas spin polarization and detection. We use a train of Rb 87 π pulses and σ+/σ- optical pumping to realize a finite-field Rb magnetometer with suppression of spin-exchange relaxation. We suppress frequency shifts from polarized Rb by measuring the He 3 and Xe 129 spin precession frequencies in the dark, while applying π pulses along two directions to depolarize Rb atoms. The plane of the π pulses is rotated to suppress the Bloch-Siegert shifts for the nuclear spins. We measure the ratio of He 3 to Xe 129 spin precession frequencies with sufficient absolute accuracy to resolve Earth's rotation without changing the orientation of the comagnetometer. A frequency resolution of 7 nHz is achieved after integration for 8 h without evidence of significant drift.

  13. Measurement of electron drift velocities in the mixture of Xe and He for a new high-pressure Xe gamma-ray detector

    CERN Document Server

    Kobayashi, S; Dmitrenko, V V

    2003-01-01

    Drift velocities of electrons in a mixture of Xe (20 atm)-He (3 atm) were measured using a cylindrical high-pressure xenon chamber. The drift velocities were found to be greater than 3x10 sup 5 cm/s above the reduced electric field of 2.0x10 sup - sup 1 sup 8 V centre dot cm sup 2 at room temperature, which are close to those in Xe-H sub 2 (0.3%). The mixture of He gas into high-pressure xenon improved the resolving time of detectors because it increased the electron drift velocities. This implies that a high-pressure xenon chamber mixed with sup 3 He instead of He gas operates as a gamma-ray detector sensitive to thermal neutrons. (author)

  14. A Preliminary Assessment of the SURF Reactive Burn Model Implementation in FLAG

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Carl Edward [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); McCombe, Ryan Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Carver, Kyle [United States Air Force, Washington, DC (United States)

    2017-09-18

    Properly validated and calibrated reactive burn models (RBM) can be useful engineering tools for assessing high explosive performance and safety. Experiments with high explosives are expensive. Inexpensive RBM calculations are increasingly relied on for predictive analysis for performance and safety. This report discusses the validation of Menikoff and Shaw’s SURF reactive burn model, which has recently been implemented in the FLAG code. The LANL Gapstick experiment is discussed as is its’ utility in reactive burn model validation. Data obtained from pRad for the LT-63 series is also presented along with FLAG simulations using SURF for both PBX 9501 and PBX 9502. Calibration parameters for both explosives are presented.

  15. Analysis of historical and recent PBX 9404 cylinder tests using FLAG

    Energy Technology Data Exchange (ETDEWEB)

    Wooten, Hasani Omar [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Whitley, Von Howard [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-01-31

    Cylinder test experiments using aged PBX-9404 were recently conducted. When compared to similar historical tests using the same materials, but different diagnostics, the data indicate that PBX 9404 imparts less energy to surrounding copper. The purpose of this work was to simulate historical and recent cylinder tests using the Lagrangian hydrodynamics code, FLAG, and identify any differences in the energetic behavior of the material. Nine experiments spanning approximately 4.5 decades were simulated, and radial wall expansions and velocities were compared. Equation-of-state parameters were adjusted to obtain reasonable matches with experimental data. Pressure-volume isentropes were integrated, and resultant energies at specific volume expansions were compared. FLAG simulations matched to experimental data indicate energetic changes of approximately -0.57% to -0.78% per decade.

  16. 14 CFR 1221.106 - Establishment of the NASA Flag.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Establishment of the NASA Flag. 1221.106 Section 1221.106 Aeronautics and Space NATIONAL AERONAUTICS AND SPACE ADMINISTRATION THE NASA SEAL AND OTHER DEVICES, AND THE CONGRESSIONAL SPACE MEDAL OF HONOR NASA Seal, NASA Insignia, NASA Logotype, NASA...

  17. 14 CFR 1221.113 - Use of the NASA Flags.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Use of the NASA Flags. 1221.113 Section 1221.113 Aeronautics and Space NATIONAL AERONAUTICS AND SPACE ADMINISTRATION THE NASA SEAL AND OTHER DEVICES, AND THE CONGRESSIONAL SPACE MEDAL OF HONOR NASA Seal, NASA Insignia, NASA Logotype, NASA Program...

  18. Study of the portal blood flow by gamma-scintigraphy in rectal administration of 133Xe solution

    International Nuclear Information System (INIS)

    Vorontsov, Yu.P.; Dmitrievnkov, B.N.; Andronov, S.V.; Alferov, G.A.

    1981-01-01

    Data on 133 Xe running through the liver during the administration of its solutions rectally (intraintestinally) and directly into the system of the portal vein (into one of the mesenteric veins) have been correlated in experiment on 12 rabbits. Good correlation of the mean of 133 Xe (passing has been shown for both methods of the portal blood flow study). A possibility to study the hepatic blood flow on the basis of clinical results using rectal administration of 133 Xe solution is discussed. The authors discuss the mechanism of 133 Xe penetration from the solution into the blood through the rectal wall

  19. Knowledge and Utilization of Red Flags by Physiotherapists in the ...

    African Journals Online (AJOL)

    DR. BASHIR BELLO

    majority of the physiotherapists 44 (88%) had knowledge of red flags but only 14 (28%) ... documented, while medical history of cancer, HIV status, as well as history of fever were .... The main objective of this study was to determine the level.

  20. 75 FR 13645 - Inventory of U.S.-Flag Launch Barges

    Science.gov (United States)

    2010-03-22

    ... Qualified Launch Barges, the Interim Final Rule requires that the Maritime Administration publish a notice... DEPARTMENT OF TRANSPORTATION Maritime Administration [Docket No. MARAD-2010 0023] Inventory of U.S.-Flag Launch Barges AGENCY: Maritime Administration, Department of Transportation. ACTION: Inventory of...

  1. 76 FR 20080 - Inventory of U.S.-Flag Launch Barges

    Science.gov (United States)

    2011-04-11

    ... Administration publish a notice in the Federal Register requesting that owners or operators (or potential owners... DEPARTMENT OF TRANSPORTATION Maritime Administration [Docket Number MARAD 2011 0030] Inventory of U.S.-Flag Launch Barges AGENCY: Maritime Administration, Department of Transportation. ACTION...

  2. Expected extreme sea levels at Forsmark and Laxemar-Simpevarp up until year 2100

    International Nuclear Information System (INIS)

    Brydsten, Lars; Engqvist, Anders; Naeslund, Jens-Ove; Lindborg, Tobias

    2009-01-01

    Literature data on factors that can affect the highest expected shoreline during the operational lifetime of a final repository up until ca 2100 AD have been compiled for Forsmark and Laxemar/Simpevarp. The study takes into consideration eustasy (global sea level), isostasy (isostatic rebound) and their trends, as well as regional (North Sea) and local (Baltic Sea) annual extremes of today's sea levels and those in year 2100. The most uncertain factor of these is the future global sea level change. For this factor, three possible scenarios have been included from the literature, forming an rough uncertainty interval around a case with an 'intermediate' global sea level. To this end, the study thus makes use of information on global sea level change that has been published since the IPCC's (UN Intergovernmental Panel on Climate Change) most recent report (2007). The local cumulative impact on the shoreline of the eustatic and isostatic components for both the Forsmark and Laxemar/Simpevarp coastal areas is that the maximum sea level occurs at the end of the investigation period, by year 2100. The interaction of these estimates is discussed in terms of coastal oceanographic aspects and estimated return periods for local extreme sea level-impacting events, including estimated storm surge. Maximum sea levels in year 2100 based on the sea level rise estimates by Rahmstorf are + 254 cm for Forsmark and + 297 cm for Laxemar/Simpevarp, both of these levels with an uncertainty interval of about ± 70 cm. The numbers apply for the worst possible case in regard to future sea level rise, and for occasions of short duration during heavy storms. In this context it is important to note that the data on which these estimates are based are the subject of intense research, and that revisions are therefore to be expected

  3. Expected extreme sea levels at Forsmark and Laxemar-Simpevarp up until year 2100

    Energy Technology Data Exchange (ETDEWEB)

    Brydsten, Lars (Umeaa Univ., Umeaa (Sweden)); Engqvist, Anders (Royal Institute of Technology, Stockholm (Sweden)); Naeslund, Jens-Ove; Lindborg, Tobias (Swedish Nuclear Fuel and Waste Management Co., Stockholm (Sweden))

    2009-01-15

    Literature data on factors that can affect the highest expected shoreline during the operational lifetime of a final repository up until ca 2100 AD have been compiled for Forsmark and Laxemar/Simpevarp. The study takes into consideration eustasy (global sea level), isostasy (isostatic rebound) and their trends, as well as regional (North Sea) and local (Baltic Sea) annual extremes of today's sea levels and those in year 2100. The most uncertain factor of these is the future global sea level change. For this factor, three possible scenarios have been included from the literature, forming an rough uncertainty interval around a case with an 'intermediate' global sea level. To this end, the study thus makes use of information on global sea level change that has been published since the IPCC's (UN Intergovernmental Panel on Climate Change) most recent report (2007). The local cumulative impact on the shoreline of the eustatic and isostatic components for both the Forsmark and Laxemar/Simpevarp coastal areas is that the maximum sea level occurs at the end of the investigation period, by year 2100. The interaction of these estimates is discussed in terms of coastal oceanographic aspects and estimated return periods for local extreme sea level-impacting events, including estimated storm surge. Maximum sea levels in year 2100 based on the sea level rise estimates by Rahmstorf are + 254 cm for Forsmark and + 297 cm for Laxemar/Simpevarp, both of these levels with an uncertainty interval of about +- 70 cm. The numbers apply for the worst possible case in regard to future sea level rise, and for occasions of short duration during heavy storms. In this context it is important to note that the data on which these estimates are based are the subject of intense research, and that revisions are therefore to be expected

  4. 50 CFR 216.46 - U.S. citizens on foreign flag vessels operating under the International Dolphin Conservation...

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 7 2010-10-01 2010-10-01 false U.S. citizens on foreign flag vessels operating under the International Dolphin Conservation Program. 216.46 Section 216.46 Wildlife and Fisheries....46 U.S. citizens on foreign flag vessels operating under the International Dolphin Conservation...

  5. A Comparison of Mindray BC-6800, Sysmex XN-2000, and Beckman Coulter LH750 Automated Hematology Analyzers: A Pediatric Study.

    Science.gov (United States)

    Ciepiela, Olga; Kotuła, Iwona; Kierat, Szymon; Sieczkowska, Sandra; Podsiadłowska, Anna; Jenczelewska, Anna; Księżarczyk, Karolina; Demkow, Urszula

    2016-11-01

    Modern automated laboratory hematology analyzers allow the measurement of over 30 different hematological parameters useful in the diagnostic and clinical interpretation of patient symptoms. They use different methods to measure the same parameters. Thus, a comparison of complete blood count made by Mindray BC-6800, Sysmex XN-2000 and Beckman Coulter LH750 was performed. A comparison of results obtained by automated analysis of 807 anticoagulated blood samples from children and 125 manual microscopic differentiations were performed. This comparative study included white blood cell count, red blood cell count, and erythrocyte indices, as well as platelet count. The present study showed a poor level of agreement between white blood cell enumeration and differentiation of the three automated hematology analyzers under comparison. A very good agreement was found when comparing manual blood smear and automated granulocytes, monocytes, and lymphocytes differentiation. Red blood cell evaluation showed better agreement than white blood cells between the studied analyzers. To conclude, studied instruments did not ensure satisfactory interchangeability and did not facilitate a substitution of one analyzer by another. © 2016 Wiley Periodicals, Inc.

  6. Comparison of air space measurement imaged by CT, small-animal CT, and hyperpolarized Xe MRI

    Science.gov (United States)

    Madani, Aniseh; White, Steven; Santyr, Giles; Cunningham, Ian

    2005-04-01

    Lung disease is the third leading cause of death in the western world. Lung air volume measurements are thought to be early indicators of lung disease and markers in pharmaceutical research. The purpose of this work is to develop a lung phantom for assessing and comparing the quantitative accuracy of hyperpolarized xenon 129 magnetic resonance imaging (HP 129Xe MRI), conventional computed tomography (HRCT), and highresolution small-animal CT (μCT) in measuring lung gas volumes. We developed a lung phantom consisting of solid cellulose acetate spheres (1, 2, 3, 4 and 5 mm diameter) uniformly packed in circulated air or HP 129Xe gas. Air volume is estimated based on simple thresholding algorithm. Truth is calculated from the sphere diameters and validated using μCT. While this phantom is not anthropomorphic, it enables us to directly measure air space volume and compare these imaging methods as a function of sphere diameter for the first time. HP 129Xe MRI requires partial volume analysis to distinguish regions with and without 129Xe gas and results are within %5 of truth but settling of the heavy 129Xe gas complicates this analysis. Conventional CT demonstrated partial-volume artifacts for the 1mm spheres. μCT gives the most accurate air-volume results. Conventional CT and HP 129Xe MRI give similar results although non-uniform densities of 129Xe require more sophisticated algorithms than simple thresholding. The threshold required to give the true air volume in both HRCT and μCT, varies with sphere diameters calling into question the validity of thresholding method.

  7. Air Quality Flags Program, U.S., 2017, EPA/OAR/OAQPS/OID

    Data.gov (United States)

    U.S. Environmental Protection Agency — This map service contains participants in EPA's Air Quality Flags Program. The map service also includes the current day's AQI forecast for each participant in the...

  8. Relaxation rates of low-field gas-phase ^129Xe storage cells

    Science.gov (United States)

    Limes, Mark; Saam, Brian

    2010-10-01

    A study of longitudinal nuclear relaxation rates T1 of ^129Xe and Xe-N2 mixtures in a magnetic field of 3.8 mT is presented. In this regime, intrinsic spin relaxation is dominated by the intramolecular spin-rotation interaction due to persistent xenon dimers, a mechanism that can be quelled by introducing large amounts of N2 into the storage cell. Extrinsic spin relaxation is dominated by the wall-relaxation rate, which is the primary quantity of interest for the various low-field storage cells and coatings that we have tested. Previous group work has shown that extremely long gas-phase relaxation times T1 can be obtained, but only at large magnetic fields and low xenon densities. The current work is motivated by the practical benefits of retaining hyperpolarized ^129Xe for extended periods of time in a small magnetic field.

  9. Less than 2 °C warming by 2100 unlikely

    Science.gov (United States)

    Raftery, Adrian E.; Zimmer, Alec; Frierson, Dargan M. W.; Startz, Richard; Liu, Peiran

    2017-09-01

    The recently published Intergovernmental Panel on Climate Change (IPCC) projections to 2100 give likely ranges of global temperature increase in four scenarios for population, economic growth and carbon use. However, these projections are not based on a fully statistical approach. Here we use a country-specific version of Kaya's identity to develop a statistically based probabilistic forecast of CO2 emissions and temperature change to 2100. Using data for 1960-2010, including the UN's probabilistic population projections for all countries, we develop a joint Bayesian hierarchical model for Gross Domestic Product (GDP) per capita and carbon intensity. We find that the 90% interval for cumulative CO2 emissions includes the IPCC's two middle scenarios but not the extreme ones. The likely range of global temperature increase is 2.0-4.9 °C, with median 3.2 °C and a 5% (1%) chance that it will be less than 2 °C (1.5 °C). Population growth is not a major contributing factor. Our model is not a `business as usual' scenario, but rather is based on data which already show the effect of emission mitigation policies. Achieving the goal of less than 1.5 °C warming will require carbon intensity to decline much faster than in the recent past.

  10. Flag varieties an interplay of geometry, combinatorics, and representation theory

    CERN Document Server

    Lakshmibai, V

    2009-01-01

    Flag varieties are important geometric objects and their study involves an interplay of geometry, combinatorics, and representation theory. This book is detailed account of this interplay. In the area of representation theory, the book presents a discussion of complex semisimple Lie algebras and of semisimple algebraic groups; in addition, the representation theory of symmetric groups is also discussed. In the area of algebraic geometry, the book gives a detailed account of the Grassmannian varieties, flag varieties, and their Schubert subvarieties. Because of the connections with root systems, many of the geometric results admit elegant combinatorial description, a typical example being the description of the singular locus of a Schubert variety. This is shown to be a consequence of standard monomial theory (abbreviated SMT). Thus the book includes SMT and some important applications - singular loci of Schubert varieties, toric degenerations of Schubert varieties, and the relationship between Schubert variet...

  11. Flow effect on {sup 135}I and {sup 135}Xe evolution behavior in a molten salt reactor

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Jianhui; Guo, Chen [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); CAS Center for Excellence in TMSR Energy System, Chinese Academy of Sciences, Shanghai 201800 (China); Cai, Xiangzhou [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); CAS Center for Excellence in TMSR Energy System, Chinese Academy of Sciences, Shanghai 201800 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Yu, Chenggang; Zou, Chunyan [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); CAS Center for Excellence in TMSR Energy System, Chinese Academy of Sciences, Shanghai 201800 (China); Han, Jianlong [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); CAS Center for Excellence in TMSR Energy System, Chinese Academy of Sciences, Shanghai 201800 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Chen, Jingen, E-mail: chenjg@sinap.ac.cn [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); CAS Center for Excellence in TMSR Energy System, Chinese Academy of Sciences, Shanghai 201800 (China); University of Chinese Academy of Sciences, Beijing 100049 (China)

    2017-04-01

    Highlights: • {sup 135}Xe and {sup 135}I evolution law in a molten salt reactor is analytically deduced. • The circulation of fuel salt through the primary loop decreases the concentration of {sup 135}I and {sup 135}Xe. • {sup 135}I and {sup 135}Xe concentration reduction is independent with the mass flow rate at normal core operating condition. • Increasing the external core volume would raise {sup 135}I and {sup 135}Xe concentration reduction caused by the flow effect. - Abstract: Molten Salt Reactor (MSR) employs fissile material dissolved in the fluoride salt as fuel which continuously circulates through the primary loop with the flow cycle time being a few tens of seconds. The nuclei evolution law is quite different from that in a solid fuel reactor. In this paper, we analytically deduce the nuclei evolution law of {sup 135}Xe and {sup 135}I which are entrained in the flowing salt, evaluate its concentration changing with the burnup time, and validate the result with the SCALE6. The circulation of fuel salt could decrease the concentration of {sup 135}Xe and {sup 135}I, and the reduction can achieve to around 40% and 50% for {sup 135}Xe and {sup 135}I respectively at a small power level (e.g., 2 MW) when the core has the same fuel salt volume as that of the outer-loop. Furthermore, it can be found that the reduction is inversely proportional to the core to outer-loop volume ratio, but uncorrelated with the mass flow rate under normal operating condition of a MSR. At low core power scale, the flow effect on {sup 135}Xe concentration reduction is apparent, but it is mitigated as the core power scale increases because of the rise of {sup 135}I concentration, which raises its decay to {sup 135}Xe and compensates the loss of {sup 135}Xe due to decay at the outer-loop. The decreased {sup 135}Xe concentration results in a core reactivity increase varying from around 150 pcm to 1000 pcm depending on the core power and core to outer-loop volume ratio.

  12. Development of a hyperpolarized 129Xe system on 3T for the rat lungs

    International Nuclear Information System (INIS)

    Sato, Hiroshi; Enmi, Jun-ichiro; Hayashi, Takuya

    2004-01-01

    MRI (magnetic resonance imaging) with 129 Xe has gained much attention as a diagnostic methodology because of its affinity for lipids and possible polarization. The quantitative estimation of net detectability and stability of hyperpolarized 129 Xe in the dissolved phase in vivo is valuable to the development of clinical applications. The goal of this study was to develop a stable hyperpolarized 129 Xe experimental 3T system to statistically analyze the dissolved-phase 129 Xe signal in the rat lungs. The polarization of 129 Xe with buffer gases at the optical pumping cell was measured under adiabatic fast passage against the temperature of an oven and laser absorption at the cell. The gases were insuffiated into the lungs of Sprague-Dawley rats (n=15, 400-550 g) through an endotracheal tube under spontaneous respiration. Frequency-selective spectroscopy was performed for the gas phase and dissolved phase. We analyzed the 129 Xe signal in the dissolved phase to measure the chemical shift, T 2 * , delay and its ratio in a rat lungs on 3T. The polarizer was able to produce polarized gas (1.1±0.47%, 120 cm 3 ) hundreds of times with the laser absorption ratio (25%) kept constant at the cell. The optimal buffer gas ratio of 25-50% rendered the maximum signal in the dissolved phase. Two dominant peaks of 211.8±0.9 and 201.1±0.6 ppm were observed with a delay of 0.4±0.9 and 0.9±1.0 s from the gas phase spectra. The ratios of their average signal to that of the gas phase were 5.6±5.2% and 4.4±4.7%, respectively. The T 2 * of the air space in the lungs was 2.5±0.5 ms, which was 3.8 times shorter than that in a syringe. We developed a hyperpolarized 129 Xe experimental system using a 3T MRI scanner that yields sufficient volume and polarization and quantitatively analyzed the dissolved-phase 129 Xe signal in the rat lungs. (author)

  13. Red Flags for Low Back Pain Are Not Always Really Red: A Prospective Evaluation of the Clinical Utility of Commonly Used Screening Questions for Low Back Pain.

    Science.gov (United States)

    Premkumar, Ajay; Godfrey, William; Gottschalk, Michael B; Boden, Scott D

    2018-03-07

    Low back pain has a high prevalence and morbidity, and is a source of substantial health-care spending. Numerous published guidelines support the use of so-called red flag questions to screen for serious pathology in patients with low back pain. This paper examines the effectiveness of red flag questions as a screening tool for patients presenting with low back pain to a multidisciplinary academic spine center. We conducted a retrospective review of the cases of 9,940 patients with a chief complaint of low back pain. The patients completed a questionnaire that included several red flag questions during their first physician visit. Diagnostic data for the same clinical episode were collected from medical records and were corroborated with imaging reports. Patients who were diagnosed as having a vertebral fracture, malignancy, infection, or cauda equina syndrome were classified as having a red flag diagnosis. Specific individual red flags and combinations of red flags were associated with an increased probability of underlying serious spinal pathology, e.g., recent trauma and an age of >50 years were associated with vertebral fracture. The presence or absence of other red flags, such as night pain, was unrelated to any particular diagnosis. For instance, for patients with no recent history of infection and no fever, chills, or sweating, the presence of night pain was a false-positive finding for infection >96% of the time. In general, the absence of red flag responses did not meaningfully decrease the likelihood of a red flag diagnosis; 64% of patients with spinal malignancy had no associated red flags. While a positive response to a red flag question may indicate the presence of serious disease, a negative response to 1 or 2 red flag questions does not meaningfully decrease the likelihood of a red flag diagnosis. Clinicians should use caution when utilizing red flag questions as screening tools.

  14. Positron annihilation and 129Xe NMR studies of free volume in polymers

    International Nuclear Information System (INIS)

    Nagasaka, Bunsow; Eguchi, Taro; Nakayama, Hirokazu; Nakamura, Nobuo; Ito, Yasuo

    2000-01-01

    The existence and the average size of free volume in bisphenol-A polycarbonate (PC), low-density polyethylene (LDPE), poly (2,6-dimethyl-phenylene oxide)(PPO), and polytetrafluoroethylene (PTFE) were studied by positron annihilation and 129 Xe NMR measurements. The 129 Xe NMR chemical shifts for xenon adsorbed in the polymers indicated that the average pore size of the free volume increased in the following order: PC, LDPE, PPO, and PTFE. This order of the pore size of the free volume agrees well with that estimated from the longest lifetime (τ 3 ) of ortho-positronium formed in the polymers. The unique correlation that δ -1 ∝ r is established between the 129 Xe NMR chemical shift (δ) and the pore size (r), which is deduced from the positron annihilation measurements.

  15. Single electron capture in N^+ -(Ne, Kr, Xe) collisions

    Science.gov (United States)

    Reyes, Pedro G.; Castillo, Fermin; Martinez, Horacio

    2001-05-01

    Total cross sections for single electron capture of N^+ ions impinging on Ne, Kr and Xe were measured in the energy range of 1.5 to 5.0 keV. The electron capture cross sections for all the targets studied are found to be in excellent agreement with previous data in the low-energy range. The present data together with previous measurements give a general shape of the whole curve of single electron capture cross sections for the N^+ - Ne system. For the cases of N^+ - (Kr, Xe) systems, semiempirical calculation using the two-state approximation are in very good agreement with present cross sections data. Research supported by DGAPA IN-100392 and CONACyT 32175-E

  16. Double optimization of Xe(L) amplifier power scaling at λ ∼ 2.9 A

    International Nuclear Information System (INIS)

    Borisov, Alex B; Song, Xiangyang; Zhang Ping; McCorkindale, John C; Khan, Shahab F; Poopalasingam, Sankar; Zhao Ji; Dai Yang; Rhodes, Charles K

    2007-01-01

    The spectral and spatial characteristics of the Xe(L) amplifier at λ ∼ 2.9 A determine an optimum for the scaling of the peak power with channel length. The Xe 31+ and Xe 32+ (3d → 2p) transition arrays represent two identical spectral optima for amplification, a property stemming from the extremum of spectral components (3245) characteristic of their electron configurations. Adroit matching of the spatial distribution of the intensity characteristic of the propagating 248 nm pulse dynamically generating the self-trapped plasma channel with the intensity required to excite selectively and efficiently the Xe 31+ and Xe 32+ arrays can also simultaneously maximize the spatial volume of the excitation. The net outcome of this double maximization is an amplifying channel for the optimal transitions that possesses high gain (∼100 cm -1 ), low losses ( -1 cm -1 ) and a diameter of 15-20 μm, a size sufficient to produce an x-ray pulse energy of ∼50-100 mJ from a channel having an average xenon density of ∼10 20 cm -3 and a length of 1 cm. Since previous studies have experimentally demonstrated the ability to produce a saturated bandwidth of ∼60 eV, a magnitude sufficient to support a pulse duration of ∼30 as, peak powers P x >> 1 PW are clearly within the scaling limits of the Xe(L) system. The corresponding peak brightness scaling limit is accordingly bounded from below by P x /λ 2 ≅ 10 30 W cm -2 sr -1 . (fast track communication)

  17. Independent yields of Kr and Xe isotopes for the photofission of heavy nuclei

    CERN Document Server

    Gangrskij, Y P; Mishinskij, G V; Penionzhkevich, Yu E; Szoelloes, O; Zhemenik, V I

    2002-01-01

    Presented are the yields of primary fission fragments (produced in the process of the rupture of the nucleus) of Kr (A = 87- 93) and Xe (A 148-143) for the photofission of sup 2 sup 3 sup 2 Th, sup 2 sup 3 sup 8 U and sup 2 sup 4 sup 4 Pu, which were measured using Bremsstrahlung from a microtron, the energy of accelerated electrons being 25 MeV. A technique was used that includes transportation of fragments escaped from the target with a gas flow through a capillary and the condensation of Kr and Xe inert gases in a cryostat at the temperature of liquid nitrogen. Fragments of all the other elements were retained with a filter at the entrance of the capillary. Kr and Xe isotopes were identified by the gamma spectra of their daughter products. The mass number distributions are obtained of the independent yields of Kr and Xe isotopes, which are compared with the similar characteristics for the fission induced by thermal and fast neutrons; the charge shifts for the fragments under study relative to the unchanged...

  18. Independent Yields of Kr and Xe Isotopes for the Photofission of Heavy Nuclei

    CERN Document Server

    Gangrsky, Yu P; Maslova, N Yu; Penionzhkevich, Yu E; Szöllös, O; Zhemenik, V I

    2002-01-01

    Presented are the yields of primary fission fragments (produced in the process of the rupture of the nucleus) of Kr (A=87-93) and Xe (A=148-143) for the photofission of ^{232}Th, ^{238}U and ^{244}Pu, which were measured using bremsstrahlung from a microtron, the energy of accelerated electrons being 25 MeV. A technique was used that includes transportation of fragments escaped from the target with a gas flow through a capillary and the condensation of Kr and Xe inert gases in a cryostat at the temperature of liquid nitrogen. Fragments of all the other elements were retained with a filter at the entrance of capillary. Kr and Xe isotopes were identified by the gamma-spectra of their daughter products. The mass number distributions are obtained of the independent yields of Kr and Xe isotopes, which are compared with the similar characteristics for the fission induced by thermal and fast neutrons; the charge shifts for the fragments under study relative to the unchanged charge distribution are determined. The pe...

  19. Ar-Xe Laser: The Path to a Robust, All-Electric Shipboard Directed Energy Weapon

    National Research Council Canada - National Science Library

    Apruzese, J. P; Sethian, J. D; Giuliani, J. L; Wolford, M. F

    2008-01-01

    .... The electron beam pumped Ar-Xe laser has been investigated in an ONR-sponsored 6.1 program at NRL. The results of this program are summarized in this Memorandum Report, and indicate that the Ar-Xe laser has strong potential to meet these requirements...

  20. Multicollector High Precision Resolution of Primordial Kr and Xe in Mantle CO2 Well Gases

    Science.gov (United States)

    Holland, G.; Ballentine, C.; Cassidy, M.

    2008-12-01

    Noble gas isotopes in magmatic CO2 well gases provide a unique insight into mantle volatile origin and dynamics [1-3]. Previous work has resolved mantle 20Ne/22Ne ratios consistent with a solar wind irradiated meteoritic source for mantle He and Ne [1]. This is distinct from Solar Wind values that might be expected if the primary mechanism of terrestrial mantle volatile acquisition was through the gravitational capture of solar nebula gases [see 4]. Within the CO2 well gases a primordial component has also been resolved in the non- radiogenic Xe isotopic composition [2,3]. Using multicollector mass spectrometry we have observed a 124Xe/130Xe excess of 1.85 percent over air plus/minus 0.17 percent for the least air contaminated samples. At this level of precision we are for the first time able to differentiate between a trapped meteoritic origin (average carbonaceous chondrite or Q Xe) rather than Solar Wind origin as the primordial Xe component. The well gases also contain Kr which, in the least air contaminated sample, have a correlated 86Kr/82Kr excess of 0.55 percent over air plus/minus 0.04 percent. Whilst mass dependent fractionation can theoretically produce correlated excesses in 124Xe-128Xe and 82Kr-86Kr isotopes, no fractionation from air is observed in 38Ar/36Ar [3] and the Kr excesses are in the opposite sense to that of Xe. From 136Xe excesses, Kr fission yield from Pu and U can be calculated and subtracted from the Kr isotopic signature. This fission-corrected signature is most reasonably explained as a primordial component. This is the first time that primordial Kr has ever been resolved in a terrestrial sample. The primordial Kr isotopic signature is distinct from Solar Wind Kr and is consistent with the primordial Kr also originating as a trapped component within meteorites. We are now able to demonstrate that both the light (He and Ne) and Heavy (Kr and Xe) noble gas origin in the terrestrial mantle is consistent with a trapped component during the

  1. Improving the efficiency of a fluorescent Xe dielectric barrier light source using short pulse excitation

    International Nuclear Information System (INIS)

    Beleznai, Sz; Mihajlik, G; Richter, P; Maros, I; Balazs, L

    2008-01-01

    Operation of a Xe dielectric barrier discharge lamp producing 147-172 nm VUV radiation is investigated both theoretically and experimentally. Xe gas pressure varies between 100 and 300 mbar, and the glass body of the lamp is coated with LAP (green) phosphor to convert radiation into the visible part of the spectrum. Simulation results predict improved discharge efficiencies reaching 67% when excited by a fast rise-time, short pulse (∼200 ns) driving waveform. In this case most power deposited into the plasma efficiently produces Xe 2 * excimers, while other energy dissipation processes (ion heating, e-Xe elastic collision) are kept at a low rate. Simulation and experimental results are compared in terms of discharge efficacy and show good agreement. A lamp efficacy value as high as 80 lm W -1 is demonstrated experimentally

  2. FLAG Simulations of the Elasticity Test Problem of Gavrilyuk et al.

    Energy Technology Data Exchange (ETDEWEB)

    Kamm, James R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Runnels, Scott R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Canfield, Thomas R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Carney, Theodore C. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-04-23

    This report contains a description of the impact problem used to compare hypoelastic and hyperelastic material models, as described by Gavrilyuk, Favrie & Saurel. That description is used to set up hypoelastic simulations in the FLAG hydrocode.

  3. General and Flag Officer Careers: Consequences of Increased Tenure

    National Research Council Canada - National Science Library

    Thie, Harry

    2001-01-01

    .... As a result of these concerns, Congress asked the Secretary of Defense to review the career patterns of flag-rank officers. It requested specific data about average time-in-grade both when selected and when promoted as well as the length of tours. It also asked the Secretary to assess the appropriateness of mandatory retirement at 35 years.

  4. Potential synergy between the Ionospheric Disturbance Flag and NeQuick-G for single frequency users

    Science.gov (United States)

    Aragon-Angel, Angela; Fortuny, Joaquim

    2016-04-01

    The document describing the particular ionospheric model developed for the Galileo satellite navigation system has been very recently released, the official Ionospheric Correction Algorithm for Galileo Single Frequency Users document (from here on-wards named Galileo-Iono), available at www.gsc-europa.eu/system/files/galileo_documents/Galileo_Ionospheric_Model.pdf. This publication allows GNSS receiver manufacturers to start the implementation of the specific algorithm targeted for their Galileo related products in order to be compliant with the Galileo system. As indicated in the Galileo OS SIS ICD, among the parameters that are broadcast in the Galileo navigation message, parameters that are sent within both F/NAV and I/NAV, one can find five Ionospheric Disturbance Flags for Regions 1 to 5 (SF1, SF2, SF3, SF4 and SF5). Nevertheless, in the current version of the model presented in the Galileo-Iono document, the Ionospheric Disturbance flags are "not used" within the Galileo ionospheric correction calculation. In this work, a potential approach to account for this information is being investigated. This plan includes the update of the Galileo ionospheric, NeQuick-G, correction model by specifying the use of these flags. Hence a customized version of the NeQuick-G model has been developed and tested. Specific scenarios will be considered to test whether this approach of considering the added value information of the Ionospheric Disturbance Flags is translated into the positioning domain. In order to assess the improvement obtained using the proposed approach five stations displaced in the five regions are used. Different days of data have been collected in nominal and disturbed conditions; the evaluation is carried out comparing the performance of the proposed approach with respect to the classical approach. The benefits of the use of the disturbance flags information are evaluated comparing the performance in similar geometry conditions.

  5. Lignite and hard coal: Energy suppliers for world needs until the year 2100 - An outlook

    International Nuclear Information System (INIS)

    Thielemann, Thomas; Schmidt, Sandro; Peter Gerling, J.

    2007-01-01

    For three years, international hard coal prices have been at rather expensive levels. Some argue that these higher prices might indicate the threat of a physical scarcity of fossil fuels - similar to the situation with oil and gas. This is not true. The supply situations with lignite and hard coal appear to be largely not critical. Adjusted to the rise in global coal consumption, which is expected until 2100, nature by and large can meet the world's coal demand. This is shown for lignite in this article and it is illustrated for hard coal here, differentiated in space and time for a world divided into eight regions and viewed for the years 2005, 2020, 2030, 2050, and 2100. The only area of potential concern is Asia (especially China). But today's and coming eager efforts in China to convert coal resources into reserves will most likely deliver the coal needed for the Chinese market. Up to the year 2100, and from a geoscientific point of view, there will be no bottleneck in coal supplies on this planet. (author)

  6. Kinetic analysis of rare gas metastable production and optically pumped Xe lasers

    Science.gov (United States)

    Demyanov, A. V.; Kochetov, I. V.; Mikheyev, P. A.; Azyazov, V. N.; Heaven, M. C.

    2018-01-01

    Optically pumped all-rare-gas lasers use metastable rare gas atoms as the lasing species in mixtures with He or Ar buffer gas. The metastables are generated in a glow discharge, and we report model calculations for the optimal production of Ne*, Ar*, Kr* and Xe*. Discharge efficiency was estimated by solving the Boltzmann equation. Laser efficiency, gain and output power of the CW optically pumped Xe laser were assessed as functions of heavier rare gas content, pressure, optical pump intensity and the optical path length. It was found that, for efficient operation the heavier rare gas content has to be of the order of one percent or less, and the total pressure—in the range 0.3-1.5 atm. Output power and specific discharge power increase approximately linearly with pump intensity over the output range from 300-500 W cm-2. Ternary mixtures Xe:Ar:He were found to be the most promising. Total laser efficiency was found to be nearly the same for pumping the 2p8 or 2p9 state, reaching 61%-70% for a pump intensity of ~720 W cm-2 when the Xe fraction was in the range 0.001 ÷ 0.01 and Ar fraction—0.1 ÷ 0.5. However, when the 2p8 state was pumped, the maximum total efficiency occurred at larger pressures than for pumping of the 2p9 state. The discharge power density required to sustain a sufficient Xe* number density was in the range of tens of watts per cubic centimeter for 50% Ar in the mixture.

  7. Depth distribution analysis of martensitic transformations in Xe implanted austenitic stainless steel

    International Nuclear Information System (INIS)

    Johnson, E.; Johansen, A.; Sarholt-Kristensen, L.; Chechenin, N.G.; Grabaek, L.; Bohr, J.

    1988-01-01

    In this work we present results from a depth distribution analysis of the martensitic phase change occurring in Xe implanted single crystals of austenitic stainless steel. Analysis was done by 'in situ' RBS/channeling analysis, X-ray diffraction and cross-section transmission electron microscopy (XTEM) of the implanted surface. It is found that the martensitic transformation of the surface layer occurs for fluences above 1x10 20 m -2 . The thickness of the transformed layer increases with fluence to ≅ 150 nm at 1x10 21 m -2 , which far exceeds the range plus straggling of the implanted Xe as calculated by the TRIM computer simulation code. Simulations using the MARLOWE code indicate that the thickness of the transformed layer coincides with the range of the small fraction of ions channeled under random implantation conditions. Using cross sectional TEM on the Xe implanted crystals, the depth distribution of gas inclusions and defects can be directly observed. Using X-ray diffraction on implanted single crystals, the solid epitaxial nature of the Xe inclusions, induced prior to the martensitic transformation, was established. The lattice constant obtained from the broad diffraction peak indicates that the pressure in the inclusions is ≅ 5 GPa. (orig./BHO)

  8. Modifying Flag Football for Gender Equitable Engagement in Secondary Schools

    Science.gov (United States)

    Kahan, David

    2008-01-01

    Flag or touch football is a popular activity unit in American secondary physical education curricula. However, unlike other sports its stigmatization as a masculine-typed activity and frequent inequitable distribution of game play opportunities at the skill positions (e.g., receiver, quarterback) results in the marginalization of female…

  9. Compliance with McDonald criteria and red flag recognition in a general neurology practice in Ireland.

    LENUS (Irish Health Repository)

    Albertyn, Christine

    2012-02-01

    BACKGROUND: The revised McDonald criteria aim to simplify and speed the diagnosis of multiple sclerosis (MS). An important principle of the criteria holds there should be no better explanation for the clinical presentation. In Miller et al.\\'s consensus statement on the differential diagnosis of MS, red flags are identified that may suggest a non-MS diagnosis. OBJECTIVE: All new patients with a practice diagnosis of MS were assessed for compliance with McDonald criteria. The group of patients not fulfilling criteria was followed up to assess compliance over time. At the end of the follow-up period, red flags were sought in the group of patients who remained McDonald criteria negative. METHODS: Clinical notes and paraclinical tests were examined retrospectively for compliance with McDonald criteria and for the presence of red flags. RESULTS: Sixty-two patients were identified, with two lost to follow-up. Twenty-six (42%) patients fulfilled criteria at diagnosis. After 53 months follow-up, 47 (78%) patients fulfilled criteria. In the 13 (22%) patients who remain McDonald criteria negative, a total of 20 red flags were identified, ranging from one to six per patient. Alternative diagnoses were considered and further investigations performed in 10 patients with no significantly abnormal results. CONCLUSION: Twenty-two percent of patients still do not fulfill McDonald criteria after 53 months. Dissemination in time was not proven in the majority of patients and the lack of follow-up neuroimaging was an important factor in this. Red flags may be useful in identifying alternative diagnoses, but the yield was low in our cohort.

  10. Recent improvements of a mobile polarizer system for {sup 129}Xe

    Energy Technology Data Exchange (ETDEWEB)

    Stahl, Vanessa; Heil, Werner; Karpuk, Sergei; Bluemler, Peter; Repetto, Maricel; Niederlaender, Benjamin; Braun, Manuel; Fuchs, Martin [Institut fuer Physik, Universitaet Mainz (Germany); Muennemann, Kerstin; Spiess, Hans [Max Planck Institute for Polymer Research Mainz (Germany)

    2013-07-01

    (HP){sup 129}Xe has numerous applications both in fundamental physics like nuclear spin clocks and in medical research, e.g. in lung MRI. We report on a compact mobile {sup 129}Xe polarizer built in order to achieve high polarization degrees operating in counter flow. The optical pumping scheme is optimized in terms of magnetic field homogeneity, rubidium saturation, freeze-thaw method, gas-transport and its storage in special vessels with low wall relaxation. This talk will cover different aspects of HP gas production, manipulation and minimization of losses due to relaxation.

  11. Dynamic moments of inertia in Xe, Cs and Ba nuclei

    International Nuclear Information System (INIS)

    El-Samman, H.; Barci, V.; Gizon, A.

    1984-01-01

    The γ-rays following the reactions induced by 12 C ions on 115 In, 112 , 117 , 122 Sn and 123 Sb targets have been investigated using six NaI(Tl) detectors in a two-dimensional arrangement. The collective moment of inertia I( 2 ) /sub band/ of 118 , 122 Xe, 123 Cs and 128 , 130 Ba have been extracted from the energy-correlation spectra. The behaviour of these nuclei and the observed differences are interpreted in terms of high-spin collective properties. Data are also presented on the effective moment of inertia I( 2 )/sub eff/ of 118 Xe and 130 Ba measured by sum-spectrometer techniques. 13 references

  12. A compact 133Xe gas dispenser

    International Nuclear Information System (INIS)

    Hawkins, T.; Harris, R.

    1977-01-01

    A dispenser for 133 Xe gas is described which is compact and simple to use, allowing the xenon to be dispensed from it shipping ampoule to suitable multi-dose injection vials in a controlled manner and with a high degree of operator safety. The apparatus has no joints and only a single rubber teat, minimizing the risks of adsorption and leakage. A scaled drawing of the dispenser is shown. (U.K.)

  13. Independent yields of Kr and Xe isotopes in the photofission of heavy nuclei

    International Nuclear Information System (INIS)

    Gangrsky, Yu.P.; Zhemenik, V.I.; Maslova, N.Yu.; Mishinsky, G.V.; Penionzhkevich, Yu.E.; Szoelloes, O.

    2003-01-01

    The yields of Kr (A = 87-93) and Xe (A = 138-143) primary fission fragments produced in 232 Th, 238 U, and 244 Pu photofission upon the scission of a target nucleus and neutron emission were measured in an experiment with bremsstrahlung from electrons accelerated to 25 MeV by a microtron, and the results of these measurements are presented. The experimental procedure used involved the transportation of fragments that escaped from the target by a gas flow through a capillary and the condensation of Kr and Xe inert gases in a cryostat at liquid-nitrogen temperature. The fragments of all other elements were retained with a filter at the capillary inlet. The isotopes of Kr and Xe were identified by the γ spectra of their daughter products. The mass-number distributions of the independent yields of Kr and Xe isotopes are obtained and compared with similar data on fission induced by thermal and fast neutrons; the shifts of the fragment charges with respect to the undistorted charge distribution are determined. Prospects for using photofission fragments in studying the structure of highly neutron-rich nuclei are discussed

  14. Investigations of an excimer laser working with a four-component gaseous mixture He-Kr:Xe-HCl

    Science.gov (United States)

    Iwanejko, Leszek; Pokora, Ludwik J.

    1991-08-01

    The paper presnts working conditions of an XCI excimer laser untypical gas mixture based on KrzXe instead of pure Xe. Such a choice was influenced by the necessity of Findin9 the way to replace imported and expensive Xe by gaseous components accesible in Poland. Determining the range of changes of laser extrnal parameters which enables its proper work with the new gas mixture was the aim of same investigations results of which are presented in this paper. The laser pulse output energy and the pulse duration as a Function of supply voltage and the mixture composition are presented. The range of proper conditions for the laser working with the new mixture He-Kr:Xe--HC1 was determined. The analysis of experimental results showed that using the new mixture ensures value of energy and pulse duration comparable with the ones obtained for the mixture He-''Xe--HCl. Spectral investigations showed the lack of influence of Kr presence in the mixture on the generation spectrum of the laser. L.

  15. Vortex dynamics behind a self-oscillating inverted flag placed in a channel flow: Time-resolved particle image velocimetry measurements

    Science.gov (United States)

    Yu, Yuelong; Liu, Yingzheng; Chen, Yujia

    2017-12-01

    The unsteady flow behind an inverted flag placed in a water channel and then excited into a self-oscillating state is measured using time-resolved particle image velocimetry. The dynamically deformed profiles of the inverted flag are determined by a novel algorithm that combines morphological image processing and principle component analysis. Three modes are discovered with the successive decrease in the dimensionless bending stiffness: the biased mode, the flapping mode, and the deflected mode. The distinctly different flow behavior is discussed in terms of instantaneous velocity field, phase-averaged vorticity field, time-mean flow field, and turbulent kinetic energy. The results demonstrated that the biased mode generated abundant vortices at the oscillating side of the inverted flag. In the deflected mode, the inverted flag is highly deflected to one side of the channel and remains almost stationary, inducing two stable recirculation zones and a considerably inversed flow between them. In the flapping mode, the strongly oscillating flag periodically provides a strengthened influence on the fluid near the two sidewalls. The reverse von Kármán vortex street is well formed and energetic in the wake, and a series of high-speed impingement jets between the neighboring vortices are directed toward the sidewalls in a staggered fashion.

  16. Multifragment emission times in Xe induced reactions

    Energy Technology Data Exchange (ETDEWEB)

    Moroni, A. [INFN and Dipartimento di Fisica, Via Celoria 16, 20133 Milano (Italy); Bowman, D.R. [AECL Research, Chalk River Laboratories, Chalk River, Ont. (Canada); Bruno, M. [Dipartimento di Fisica and INFN, Via Irnerio 46, 40126 Bologna (Italy); Buttazzo, P. [Dipartimento di Fisica and INFN, Via A. Valerio 2, 34127 Trieste (Italy); Celano, L. [INFN, Via Amendola 173, 70126 Bari (Italy); Colonna, N. [INFN, Via Amendola 173, 70126 Bari (Italy); D`Agostino, M. [Dipartimento di Fisica and INFN, Via Irnerio 46, 40126 Bologna (Italy); Dinius, J.D. [NSCL, Michigan State University, E. Lansing, 48824 MI (United States); Ferrero, A. [INFN and Dipartimento di Fisica, Via Celoria 16, 20133 Milano (Italy); Fiandri, M.L. [Dipartimento di Fisica and INFN, Via Irnerio 46, 40126 Bologna (Italy); Gelbke, K. [NSCL, Michigan State University, E. Lansing, 48824 MI (United States); Glasmacher, T. [NSCL, Michigan State University, E. Lansing, 48824 MI (United States); Gramegna, F. [INFN Laboratori Nazionali di Legnaro, Via Romea 4, 35020 Legnaro (Italy); Handzy, D.O. [NSCL, Michigan State University, E. Lansing, 48824 MI (United States); Horn, D. [AECL Research, Chalk River Laboratories, Chalk River, Ont. (Canada); Hsi Wenchien [NSCL, Michigan State University, E. Lansing, 48824 MI (United States); Huang, M. [NSCL, Michigan State University, E. Lansing, 48824 MI (United States); Iori, I. [INFN and Dipartimento di Fisica, Via Celoria 16, 20133 Milano (Italy); Lisa, M. [NSCL, Michigan State University, E. Lansing, 48824 MI (United States); Lynch, W.G. [NSCL, Michigan State University, E. Lansing, 48824 MI (United States); Margagliotti, G.V. [Dipartimento di Fisica and INFN, Via A. Valerio 2, 34127 Trieste (Italy); Mastinu, P.F. [Dipartimento di Fisica and INFN, Via Irnerio 46, 40126 Bologna (Italy); Milazzo, P.M. [Dipartimento di Fisica and INFN, Via Irnerio 46, 40126 Bologna (Italy); Montoya, C.

    1995-02-06

    Multifragment emission is studied in {sup 129}Xe+{sup nat}Cu reactions. The emission process for central collisions occurs on a time scale of similar 200fm/c at 30MeV/n. Intermediate-mass-fragment yields, velocity correlation functions and emission velocities of Z=6 fragments are compared with predictions of statistical decay models. ((orig.)).

  17. Cross section TEM characterization of high-energy-Xe-irradiated U-Mo

    Energy Technology Data Exchange (ETDEWEB)

    Ye, B., E-mail: bye@anl.gov [Nuclear Engineering Division, Argonne National Laboratory, 9700 S. Cass Ave. Lemont, IL 60439 (United States); Jamison, L.; Miao, Y. [Nuclear Engineering Division, Argonne National Laboratory, 9700 S. Cass Ave. Lemont, IL 60439 (United States); Bhattacharya, S. [Department of Materials Science and Engineering, Northwestern University, 2220 Campus Dr. Evanston, IL 60208 (United States); Hofman, G.L.; Yacout, A.M. [Nuclear Engineering Division, Argonne National Laboratory, 9700 S. Cass Ave. Lemont, IL 60439 (United States)

    2017-05-15

    U-Mo alloys irradiated with 84 MeV Xe ions to various doses were characterized with transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM) techniques. The TEM thin foils were prepared perpendicular to the irradiated surface to allow a direct observation of the entire region modified by ions. Therefore, depth-selective microstructural information was revealed. Varied irradiation-induced phenomena such as gas bubble formation, phase reversal, and recrystallization were observed at different ion penetration depths in U-Mo. - Highlights: •Three distinct zones were observed along the ion traveling direction in U-7Mo irradiated with 84 MeV Xe ions at 350 °C. •The α-U particles within the Xe-implanted region were reverted to γ-U phase by irradiation. •High-density random intra-granular bubbles in a size of 4–5 nm were found in the irradiated region, coexisting with large inter-granular bubbles. •The high lattice stresses built up during the irradiation-induced phase reversal is probably the driving force for the small grain formation at cell boundaries.

  18. The study of multicomponent separation of Xe isotope by centrifugal method

    International Nuclear Information System (INIS)

    Jinyan Wu; Fu Zhuge

    1996-01-01

    The element Xe has nine isotopes in nature, the separation performance of each component mutually affects the others, so the binary separation theory can't be employed to study the multicomponent separation. Especially, when the molecular wight of a certain component is in the middle of its isotope components, the effect of the others on this component must be considered. In this paper, first, the multicomponent separation of Xe isotopes in a gas centrifuge is studied, with the consideration of the effect of the concentration on the diffusion coefficient and average molecular weight. The multicomponent diffusion equations are solved by the finite difference method. Second, the enrichment of Xe isotopes in a cascade is studied. On the basis of the study of a gas centrifuge, the simplified separation equations of a gas centrifuge for cascade calculation are obtained. Furthermore, the complete equations of the cascade separation are established according to the conservation of mass of each component and solved by a numerical method. The study of this paper can be extended for other isotope separation calculations. (author)

  19. Compact 4-kHz XeF-laser with multisectional discharge gap

    Science.gov (United States)

    Andramanov, A. V.; Kabaev, S. A.; Lazhintsev, Boris V.; Nor-Arevyan, Vladimir A.; Selemir, V. D.

    2005-03-01

    An electric-discharge XeF-laser with a pulse repetition rate up to 4 kHz was developed. The laser electrode unit was made on the basis of plate-like electrodes with inductive-capacity discharge stabilization. The narrow discharge width laser energy was 3 mJ by using He/Xe/NF3 and Ne/Xe/NF3 mixtures at the total pressure of 0.8 atm and 1.2 atm, respectively. The maximum laser efficiency was ~ 0.73% The gas flow was formed with the help of a diametrical fan rotated by the direct-current motor with 80 W power. The gas velocity of 20 m/s in the interelectrode gap was achieved. The laser pulse energy for a pulse repetition rate up to 3.5...4 kHz was virtually equal to the laser pulse energy in the infrequently-repeating-pulse regime. The average output power of 12 W at the pulse repetition rate of 4 kHz was achieved. The relative root-mean-square pulse-to-pulse variation of the output energy σ = 2.5% was reached.

  20. Evolution of Xe spectrum and ion charge under sudden incoming radiation

    Science.gov (United States)

    Klapisch, Marcel; Busquet, Michel

    2012-06-01

    Experiments [1] and simulations of Xe at high temperature were recently reported, due to the possible scaling of astrophysical radiative shocks [2]. We used the newest version of HULLAC [3] to compute energy levels, radiative and collisional transition rates and level populations in a Coronal Radiative Model for the ions Xe9+ to Xe44+ (36263 configurations), at electron temperature of 100 eV and electron density of 10^19 -- 10^21 e/cm^3, in the presence of an external Planckian radiation field. Static and time dependent influence of the radiation on ion charge and spectrum is described. We show an effect of shell structure on relaxation of ion charge when the radiation field is suddenly turn on.[4pt] [1] Busquet, M., Thais, F., Gonzalez, M., et al., J. App. Phys. 107, 083302 (2010).[0pt] [2] Ryutov, D., Drake, R. P., Kane, J., et al., Astrophys. J. 518, 821 (1999).[0pt] [3] Klapisch, M. and Busquet, M., High Ener. Dens. Phys. 7, 98 (2011).

  1. Regional cerebral blood flow measurements using noninvasive 133Xe clearance method in children

    International Nuclear Information System (INIS)

    Nishimoto, Hiroshi; Maeda, Koji; Kagawa, Yukihide; Morozumi, Kunihiko; Hashimoto, Manami; Tsubokawa, Takashi.

    1985-01-01

    The noninvasive 133-Xe clearance method of estimating rCBF has been widely used in adult clinical studies. It is safe, noninvasive and reproducible, and has provided valuable insight into adult cerebrovascular pathophysiology. However, in children, this technique has not been used to measure rCBF for some fundamental problems. This study was performed to clarify these fundamental problems for applications of noninvasive 133-Xe clearance technique to children. The results showed that three fundamental problems concerning; (1) volume of dead spaces in airway circuits of the system, (2) increasing of look-through phenomenon and (3) correction methods for recirculated 133-Xe and airway artifacts to estimate rCBF are important for applications to children. These problems should be improved to measure as correct rCBF in children as in adults. (author)

  2. The blood-stained flags of liberty – The struggle for adequate signs of identity in New Caledonia

    Directory of Open Access Journals (Sweden)

    Lindenmann, Peter

    2014-09-01

    Full Text Available The Nouméa treaty of 1998 that created the framework for the transition of New Caledonia from a French overseas territory towards emancipation provided also for the creation of new identity markers. Lacking a shared understanding of history and a common vision for the future, the process of adopting a flag was blocked for more than ten years. As an intermediate solution the flag of the Kanak independence movement is hoisted side by side to the French tricolour since 2010. While some loyalist parties continue to campaign for a common flag, pro-independence parties are waiting to descend the tricolour, and others would favor the status quo. The unresolved question of the right symbol is also a reflection of the uncertain political future as the referendum on independence looms.

  3. Synthesis and X-ray crystal structure of (OsO(3)F(2))(2)2XeOF(4) and the Raman spectra of (OsO(3)F(2))(infinity), (OsO(3)F(2))(2), and (OsO(3)F(2))(2)2XeOF(4).

    Science.gov (United States)

    Hughes, Michael J; Mercier, Hélène P A; Schrobilgen, Gary J

    2009-05-18

    The adduct, (OsO(3)F(2))(2)2XeOF(4), was synthesized by dissolution of the infinite chain polymer, (OsO(3)F(2))(infinity), in XeOF(4) solvent at room temperature followed by removal of excess XeOF(4) under dynamic vacuum at 0 degrees C. Continued pumping at 0 degrees C resulted in removal of associated XeOF(4), yielding (OsO(3)F(2))(2), a new low-temperature phase of OsO(3)F(2). Upon standing at 25 degrees C for 1(1)/(2) h, (OsO(3)F(2))(2) underwent a phase transition to the known monoclinic phase, (OsO(3)F(2))(infinity). The title compounds, (OsO(3)F(2))(infinity), (OsO(3)F(2))(2), and (OsO(3)F(2))(2)2XeOF(4) have been characterized by low-temperature (-150 degrees C) Raman spectroscopy. Crystallization of (OsO(3)F(2))(2)2XeOF(4) from XeOF(4) solution at 0 degrees C yielded crystals suitable for X-ray structure determination. The structural unit contains the (OsO(3)F(2))(2) dimer in which the OsO(3)F(3) units are joined by two Os---F---Os bridges having fluorine bridge atoms that are equidistant from the osmium centers (2.117(5) and 2.107(4) A). The dimer coordinates to two XeOF(4) molecules through Os-F...Xe bridges in which the Xe...F distances (2.757(5) A) are significantly less than the sum of the Xe and F van der Waals radii (3.63 A). The (OsO(3)F(2))(2) dimer has C(i) symmetry in which each pseudo-octahedral OsO(3)F(3) unit has a facial arrangement of oxygen ligands with XeOF(4) molecules that are only slightly distorted from their gas-phase C(4v) symmetry. Quantum-chemical calculations using SVWN and B3LYP methods were employed to calculate the gas-phase geometries, natural bond orbital analyses, and vibrational frequencies of (OsO(3)F(2))(2), (OsO(3)F(2))(2)2XeOF(4), XeOF(4), OsO(2)F(4), and (mu-FOsO(3)F(2))(2)OsO(3)F(-) to aid in the assignment of the experimental vibrational frequencies of (OsO(3)F(2))(2), (OsO(3)F(2))(2)2XeOF(4), and (OsO(3)F(2))(infinity). The vibrational modes of the low-temperature polymeric phase, (OsO(3)F(2))(infinity), have been

  4. The Explicit Construction of Einstein Finsler Metrics with Non-Constant Flag Curvature

    Directory of Open Access Journals (Sweden)

    Enli Guo

    2009-04-01

    Full Text Available By using the Hawking Taub-NUT metric, this note gives an explicit construction of a 3-parameter family of Einstein Finsler metrics of non-constant flag curvature in terms of navigation representation.

  5. Production of 125I from amorphous films of Si doped with 124Xe and evaluation of its potential use in brachytherapy

    International Nuclear Information System (INIS)

    Leal, Alexandre S.; Viana, Gustavo A.

    2015-01-01

    This work describes the simulation of a new material that can be used in the brachytherapy treatment. The material consists of xenon-incorporated amorphous silicon (Xe@a-Si). The irradiated 124 Xe atoms of the samples are converted into 125 Xe, according to the reaction: 124 Xe (n,γ) 125 Xe that, in turn, decays to the radioisotope 125 I. A set of simulations performed using the MCNP5 code, shows that, in principle, the material proposed can be used in the seed of brachytherapy in the clinical treatment. (author)

  6. Multifragmentation in 30 MeV/u [sup 129]Xe induced reactions

    Energy Technology Data Exchange (ETDEWEB)

    Colonna, N. (INFN, Bari (Italy)); Bowman, D.R. (Chalk River Lab. (Canada)); Brambilla, S. (Dipt. di Fisica and INFN, Milan (Italy)); Bruno, M. (Dipt. di Fisica and INFN, Bologna (Italy)); Buttazzo, P. (Dipt. di Fisica and INFN, Trieste (Italy)); Celano, L. (INFN, Bari (Italy)); Chiodini, S. (Dipt. di Fisica and INFN, Milan (Italy)); D' Agostino, M. (Dipt. di Fisica and INFN, Bologna (Italy)); Dinius, J.D. (Michigan State Univ., East Lansing, MI (United States). National Superconducting Cyclotron Lab.); Ferrero, A. (Dipt. di Fisica and INFN, Milan (Italy)); Gelbke, K. (Michigan State Univ., East Lansing, MI (United States). National Superconducting Cyclotron Lab.); Glasmacher, T. (Michigan State Univ., East Lansing, MI (United States). National Superconducting Cyclotron Lab.); Gramegna, F. (INFN, Lab. Nazionali, Legnaro (Italy)); Handzy, D.O. (Michigan State Univ., East Lansing, MI (United States). National Superconducting Cyclotron Lab.); Horn, D. (Chalk River Lab. (Canad

    1994-01-01

    Multifragmentation processes in the 30 MeV/u [sup 129]Xe + [sup nat]Cu and [sup 129]Xe + [sup 197]Au reactions were studied with a low threshold, high-granularity 4[pi] detection system. Fragment velocity distributions have been measured at forward angles as a function of the total charged particle multiplicity. While a two-source pattern is observed for the peripheral collisions, no evidence of a dinuclear emission pattern is found for the most central collisions. Kinematical observables, such as fragment relative velocity, relative angle and reduced velocity correlation functions indicate a fast timescale of the multifragmentation process in these reactions. (orig.)

  7. Probing zeolite internal structures using very low temperature 129Xe NMR

    International Nuclear Information System (INIS)

    Labouriau, A.; Crawford, S.N.; Earl, W.L.; Pietrass, T.; Weber, W.A.; Panjabi, G.; Gates, B.C.

    1998-01-01

    In recent years, probing pore structure with 129 Xe NMR has received a bad reputation. This is due to the fact that the method is more complex than was originally suggested so the data is somewhat difficult to interpret. The authors find that the use of a wide temperature range (40--350 K) allows them to interpret 129 Xe chemical shifts in terms of van der Waals attraction between the xenon atom and oxygen in zeolite walls. Using rather simple models from the literature, they can extract useful pore size information as well as the van der Waals potential energy

  8. Probing the porosity of cocrystallized MCM-49/ZSM-35 zeolites by hyperpolarized 129Xe NMR.

    Science.gov (United States)

    Liu, Yong; Zhang, Weiping; Xie, Sujuan; Xu, Longya; Han, Xiuwen; Bao, Xinhe

    2008-01-31

    One- and two-dimensional 129Xe NMR spectroscopy has been employed to study the porosity of cocrystallized MCM-49/ZSM-35 zeolites under the continuous flow of hyperpolarized xenon gas. It is found by variable-temperature experiments that Xe atoms can be adsorbed in different domains of MCM-49/ZSM-35 cocrystallized zeolites and the mechanically mixed counterparts. The exchange of Xe atoms in different types of pores is very fast at ambient temperatures. Even at very low temperature two-dimensional exchange spectra (EXSY) show that Xe atoms still undergo much faster exchange between MCM-49 and ZSM-35 analogues in the cocrystallized zeolites than in the mechanical mixture. This demonstrates that the MCM-49 and ZSM-35 analogues in cocrystallized zeolites may be stacked much closer than in the physical mixture, and some parts of intergrowth may be formed due to the partially similar basic structure of MCM-49 and ZSM-35.

  9. Differential and integral cross sections in OH(X) + Xe collisions

    Energy Technology Data Exchange (ETDEWEB)

    Sarma, Gautam; Saha, Ashim Kumar; Meulen, J. J. ter; Parker, David H., E-mail: parker@science.ru.nl [Institute for Molecules and Materials, Radboud University Nijmegen, Heijendaalseweg 135, 6525 ED Nijmegen (Netherlands); Marinakis, Sarantos, E-mail: s.marinakis@qmul.ac.uk [School of Biological and Chemical Sciences, Queen Mary University of London, Joseph Priestley Building, Mile End Road, London E1 4NS (United Kingdom)

    2015-01-21

    Differential cross sections (DCSs) for inelastic collisions of OH(X) with Xe have been measured at a collision energy of 483 cm{sup −1}. The hydroxyl (OH) radicals were initially prepared in the X{sup 2}Π{sub 3/2} (v = 0, j = 1.5, f) level using the hexapole electric field selection method. Products were detected state-selectively by [2 + 1] resonance-enhanced multiphoton ionization of OH, combined with velocity-map imaging. Integral cross sections in OH(X) + Xe at a collision energy of 490 cm{sup −1} were also measured by laser-induced fluorescence. The results are compared with exact close-coupling quantum mechanical scattering calculations on the only available ab initio potential energy surface (PES). The agreement between experimental and theoretical results is generally very satisfactory. This highlights the ability of such measurements to test the available PES for such a benchmark open-shell system. The agreement between experiment and theory for DCSs is less satisfactory at low scattering angles, and possible reasons for this disagreement are discussed. Finally, theoretical calculations of OH(X) + He DCSs have been obtained at various collision energies and are compared with those of OH(X) + Xe. The role of the reduced mass in the DCSs and partial cross sections is also examined.

  10. Differential and integral cross sections in OH(X) + Xe collisions

    International Nuclear Information System (INIS)

    Sarma, Gautam; Saha, Ashim Kumar; Meulen, J. J. ter; Parker, David H.; Marinakis, Sarantos

    2015-01-01

    Differential cross sections (DCSs) for inelastic collisions of OH(X) with Xe have been measured at a collision energy of 483 cm −1 . The hydroxyl (OH) radicals were initially prepared in the X 2 Π 3/2 (v = 0, j = 1.5, f) level using the hexapole electric field selection method. Products were detected state-selectively by [2 + 1] resonance-enhanced multiphoton ionization of OH, combined with velocity-map imaging. Integral cross sections in OH(X) + Xe at a collision energy of 490 cm −1 were also measured by laser-induced fluorescence. The results are compared with exact close-coupling quantum mechanical scattering calculations on the only available ab initio potential energy surface (PES). The agreement between experimental and theoretical results is generally very satisfactory. This highlights the ability of such measurements to test the available PES for such a benchmark open-shell system. The agreement between experiment and theory for DCSs is less satisfactory at low scattering angles, and possible reasons for this disagreement are discussed. Finally, theoretical calculations of OH(X) + He DCSs have been obtained at various collision energies and are compared with those of OH(X) + Xe. The role of the reduced mass in the DCSs and partial cross sections is also examined

  11. Physiological and Biochemical Characteristics in Flag Leaves of the C Liangyou Series of Hybrid Rice Combinations at Late Growth Stages

    Directory of Open Access Journals (Sweden)

    Wen-bang TANG

    2010-12-01

    Full Text Available The contents of chlorophyll, soluble sugars, soluble proteins and thiobarbituric acid reaction substance (TBARS, chlorophyll fluorescence parameters, net photosynthetic rate as well as the activities of superoxide dismutase (SOD and peroxidase (POD of flag leaves at the late growth stages were studied by using C Liangyou series of hybrid rice combinitions as material and Shanyou 63 as control. The C Liangyou series of hybrid rice combinations used in the experiment included C Liangyou 396, C Liangyou 87, C Liangyou 755 and C Liangyou 34, which all used C815S as male sterile line. The contents of chlorophyll, soluble sugars and soluble proteins in flag leaves of the C Liangyou series combinations at the late growth stages were higher than those of the control, whereas the TBARS content was lower than that of the control. The activities of SOD and POD were significantly higher than those of the control on the 7th day after heading, and then decreased slowly. FPSII value and qP value of flag leaves decreased at the late growth stages, and these two parameters in flag leaves of the C Liangyou series combinations were higher than those of the control, while the qN value increased at the late growth stages and was lower than that of the control. The net photosynthetic rate of flag leaves at the late growth stage was higher compared with the control. These results suggest that slow senescence and strong photosynthetic capability in flag leaves at the late growth stages are the physiological basis of the C Liangyou series combinations.

  12. CNNs flag recognition preprocessing scheme based on gray scale stretching and local binary pattern

    Science.gov (United States)

    Gong, Qian; Qu, Zhiyi; Hao, Kun

    2017-07-01

    Flag is a rather special recognition target in image recognition because of its non-rigid features with the location, scale and rotation characteristics. The location change can be handled well by the depth learning algorithm Convolutional Neural Networks (CNNs), but the scale and rotation changes are quite a challenge for CNNs. Since it has good rotation and gray scale invariance, the local binary pattern (LBP) is combined with grayscale stretching and CNNs to make LBP and grayscale stretching as CNNs pretreatment, which can not only significantly improve the efficiency of flag recognition, but can also evaluate the recognition effect through ROC, accuracy, MSE and quality factor.

  13. Enhancement of molecular NMR signal induced by polarization transfer from laser-polarized 129Xe

    International Nuclear Information System (INIS)

    Sun Xianping

    2001-01-01

    There is a large non-equilibrium nuclear polarization and a longer relaxation time in the laser-polarized 129 Xe produced by means of optical pumping and spin exchange. The characteristics of the laser-polarized 129 Xe permit the transfer of the polarization to enhance the atomic nuclear spin in liquid, solid and surface of solid molecules. Therefore, the sensitivity in nuclear magnetic resonance measurements for the molecules is enhanced and applications in the investigations of materials and surface sciences are expanded. The progress in the investigations of materials and surface sciences are expanded. The progress in the investigations of the polarization transfer between laser-polarized 129 Xe and the atomic nuclei in the molecules, the relative physics and the measurement of some parameters are introduced

  14. Probing the regional distribution of pulmonary gas exchange through single-breath gas- and dissolved-phase 129Xe MR imaging.

    Science.gov (United States)

    Kaushik, S Sivaram; Freeman, Matthew S; Cleveland, Zackary I; Davies, John; Stiles, Jane; Virgincar, Rohan S; Robertson, Scott H; He, Mu; Kelly, Kevin T; Foster, W Michael; McAdams, H Page; Driehuys, Bastiaan

    2013-09-01

    Although some central aspects of pulmonary function (ventilation and perfusion) are known to be heterogeneous, the distribution of diffusive gas exchange remains poorly characterized. A solution is offered by hyperpolarized 129Xe magnetic resonance (MR) imaging, because this gas can be separately detected in the lung's air spaces and dissolved in its tissues. Early dissolved-phase 129Xe images exhibited intensity gradients that favored the dependent lung. To quantitatively corroborate this finding, we developed an interleaved, three-dimensional radial sequence to image the gaseous and dissolved 129Xe distributions in the same breath. These images were normalized and divided to calculate "129Xe gas-transfer" maps. We hypothesized that, for healthy volunteers, 129Xe gas-transfer maps would retain the previously observed posture-dependent gradients. This was tested in nine subjects: when the subjects were supine, 129Xe gas transfer exhibited a posterior-anterior gradient of -2.00 ± 0.74%/cm; when the subjects were prone, the gradient reversed to 1.94 ± 1.14%/cm (P exchange caused by differences in lung inflation and posture.

  15. [Complete blood count reference values of donated cord blood from Korean neonates].

    Science.gov (United States)

    Lee, Hye Ryun; Shin, Sue; Yoon, Jong Hyun; Kim, Byoung Jae; Hwang, Kyu Ri; Kim, Jin Ju; Roh, Eun Youn

    2009-06-01

    In the public cord blood (CB) banks, only safe CB units with adequate cell doses are processed and stored. Complete blood count (CBC) of CB is crucial for estimating total nucleated cells (TNC) and screening suitable CB units without hematologic abnormalities. We analyzed CBC parameters of the donated CB from healthy Korean neonates to establish CBC reference values. A total of 2,129 Korean CB units, donated and processed during the period from August 2007 to December 2007, were enrolled. We measured hemoglobin (Hb), white blood cell (WBC) count, differential count of WBC, platelets and nucleated red blood cell (nRBC) count by XE-2100 automated hematology analyzer (Sysmex, Japan), and estimated reference value of each parameter by using parametric (Mean+/-2SD) and/or non-parametric methods (2.5-97.5 percentile). And also, we compared the result of each parameter in relation to sex of neonates and delivery method. Because the differences of CBC values among different subgroups were not remarkable, we established the reference intervals as follows without subgroup division: Hb, 9.0-14.4 g/dL; WBC count, 5.6-18.5 x 10(3)/microL; differential count of WBC (neutrophils, 40.8-72.4%; lymphocytes, 17.2-46.7%; monocytes, 4.9-12.8%; eosinophils, 0.7-7.0%; basophils, 0.0-1.6%); platelet, 130-287 x 10(3)/microL; nRBCs, 0.0-13.1/100 WBC. We established cord blood CBC reference values of healthy Korean neonates using a large-scale CB units. The established CBC reference values from our study will be useful as basic data for CBC interpretation and assessment of transplant suitability of donated CB.

  16. Establishment of reference intervals for complete blood count parameters during normal pregnancy in Beijing.

    Science.gov (United States)

    Li, Aiwei; Yang, Shuo; Zhang, Jie; Qiao, Rui

    2017-11-01

    To observe the changes of complete blood count (CBC) parameters during pregnancy and establish appropriate reference intervals for healthy pregnant women. Healthy pregnant women took the blood tests at all trimesters. All blood samples were processed on Sysmex XE-2100. The following CBC parameters were analyzed: red blood cell count (RBC), hemoglobin (Hb), hematocrit (Hct), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), red blood cell distribution width (RDW), platelet count (PLT), mean platelet volume (MPV), platelet distribution width (PDW), white blood cell count (WBC), and leukocyte differential count. Reference intervals were established using the 2.5th and 97.5th percentile of the distribution. Complete blood count parameters showed dynamic changes during trimesters. RBC, Hb, Hct declined at trimester 1, reaching their lowest point at trimester 2, and began to rise again at trimester 3. WBC, neutrophil count (Neut), monocyte count (MONO), RDW, and PDW went up from trimester 1 to trimester 3. On the contrary, MCHC, lymphocyte count (LYMPH), PLT, and MPV gradually descended during pregnancy. There were statistical significances in all CBC parameters between pregnant women and normal women, regardless of the trimesters (Ppregnancy) as follows: RBC 4.50 vs 3.94×10 12 /L, Hb 137 vs 120 g/L, WBC 5.71 vs 9.06×10 9 /L, LYMPH% 32.2 vs 18.0, Neut% 58.7 vs 75.0, and PLT 251 vs 202×10 9 /L. The changes of CBC parameters during pregnancy are described, and reference intervals for Beijing pregnant women are demonstrated in this study. © 2017 Wiley Periodicals, Inc.

  17. Guidance for Reviewing OCSPP 850.2100 Avian Oral Toxicity Studies Conducted with Passerine Birds

    Science.gov (United States)

    Guidance based on comparison of results from the TG223 validation studies to results from avian acute oral studies previously submitted to EPA for two test chemicals following EPA's 850.2100 (public draft) guidelines.

  18. Experimental studies of self-suppression of vacuum ultraviolet generation in Xe

    International Nuclear Information System (INIS)

    Judish, J.P.; Allman, S.L.; Garrett, W.R.; Payne, M.G.

    1988-11-01

    Vacuum ultraviolet light in the range 116 nm to 117 nm was produced by using a two-photon resonant four-wave mixing scheme in Xe. The buildup of coherent cancellation of the two-photon resonant transition employed in the generation of the vacuum ultraviolet, with resulting limitations imposed on the achievable vacuum ultraviolet intensity was investigated. Under certain predicted conditions, increases in the intensity of one of the pumping beams, ∼1500 nm infrared, or tuning this beam towards resonance with the 5p 5 7s(3/2) 1 level of Xe led, not to increases, but decreases in the vacuum ultraviolet generated. 3 refs., 3 figs

  19. Electrical and chemical properties of XeCl*(308 nm) exciplex lamp created by a dielectric barrier discharge

    International Nuclear Information System (INIS)

    Baadj, S.; Harrache, Z.; Belasri, A.

    2013-01-01

    The aim of this work is to highlight, through numerical modeling, the chemical and the electrical characteristics of xenon chloride mixture in XeCl* (308 nm) excimer lamp created by a dielectric barrier discharge. A temporal model, based on the Xe/Cl 2 mixture chemistry, the circuit and the Boltzmann equations, is constructed. The effects of operating voltage, Cl 2 percentage in the Xe/Cl 2 gas mixture, dielectric capacitance, as well as gas pressure on the 308-nm photon generation, under typical experimental operating conditions, have been investigated and discussed. The importance of charged and excited species, including the major electronic and ionic processes, is also demonstrated. The present calculations show clearly that the model predicts the optimal operating conditions and describes the electrical and chemical properties of the XeCl* exciplex lamp

  20. Electrical and chemical properties of XeCl*(308 nm) exciplex lamp created by a dielectric barrier discharge

    Science.gov (United States)

    Baadj, S.; Harrache, Z.; Belasri, A.

    2013-12-01

    The aim of this work is to highlight, through numerical modeling, the chemical and the electrical characteristics of xenon chloride mixture in XeCl* (308 nm) excimer lamp created by a dielectric barrier discharge. A temporal model, based on the Xe/Cl2 mixture chemistry, the circuit and the Boltzmann equations, is constructed. The effects of operating voltage, Cl2 percentage in the Xe/Cl2 gas mixture, dielectric capacitance, as well as gas pressure on the 308-nm photon generation, under typical experimental operating conditions, have been investigated and discussed. The importance of charged and excited species, including the major electronic and ionic processes, is also demonstrated. The present calculations show clearly that the model predicts the optimal operating conditions and describes the electrical and chemical properties of the XeCl* exciplex lamp.

  1. Total and elastic electron scattering cross sections from Xe at intermediate and high energies

    International Nuclear Information System (INIS)

    Garcia, G; Pablos, J L de; Blanco, F; Williart, A

    2002-01-01

    Experimental total electron scattering cross sections from Xe in the energy range 300-5000 eV have been obtained with experimental errors of about 3%. The method was based on the measurement of the attenuation of a linear electron beam through a Xe gas cell in combination with an electron spectroscopy technique to analyse the energy of the transmitted electrons. Differential and integral elastic cross sections have been calculated using a scattering potential method which includes relativistic effects. The consistency of our theoretical and experimental results is also discussed in the paper. Finally, analytical formulae depending on two parameters, namely the number of target electrons and the atomic polarizability, are given to reproduce the experimental data for Ne, Ar, Kr and Xe in the energy range 500-10 000 eV

  2. Radiopharmacology of inhaled 133Xe in skeletal sites containing deposits of Gaucher cells

    International Nuclear Information System (INIS)

    Castronovo, F.P. Jr.; McKusick, K.A.; Doppelt, S.H.; Barton, N.W.

    1993-01-01

    Gaucher's disease is a lysomal storage disease in which cells of the reticuloendothelial system accumulate the lipid glucocerebroside. It is characterized by slowly progressive visceral and osseous involvement. One of the latter manifestations includes lipid infiltration of bone marrow. We monitored the rate of the inhaled 133 Xe uptake and wash-out over diseased and normal metaphyseal and epiphyseal areas of the knee. Twenty-two patients (15 adults, 7 children) with various degrees of previously diagnosed Gaucher's disease were positioned supine under a γ-camera interfaced to a computer system. All patients rebreathed 133 Xe gas from a closed system for 10 min followed by 14 min of wash-out. Digitized images of the lung, liver, spleen, bony sites and soft tissue were obtained at 1 min intervals during the wash-in and wash-out phases. Counts for each ROI were normalized per 100 pixels and plotted as a function (time). Maximum uptake was also calculated by relating the counts/ROI/100 pixels to the 10 min integrated lung count during equilibrium (the administered ''dose''). There was essentially no 133 Xe uptake in liver and spleen involved with Gaucher's disease. Monophasic uptake and biphasic wash-out curves were observed in the limited investigative population. Gaucher deposits released the 133 Xe at a greater rate relative to soft tissue. (Author)

  3. Separation of Kr-Xe system by thermal diffusion method

    International Nuclear Information System (INIS)

    Yoshida, Hiroshi; Numata, Kazuyoshi; Matsuda, Yuji; Ouchi, Misao; Naruse, Yuji

    1979-11-01

    Separation experiments of Kr-Xe system were carried out to study the possibility of adapting thermal diffusion method for concentration of krypton in a fuel reprocessing off-gas treatment process. The results are as follows. (1) A batchwise thermal diffusion column of hot tube diameter 21 mm, cold tube diameter 32 mm, effective hight 1000 mm and volume -- 500 CC is the best in separation characteristics and in ease of operation under the different conditions. (2) The overall separation factor increases with increase of the operating temperature in the column with and without reservoir. (3) The optimum operating pressure (about 400 Torr) is independent of the operating conditions such as temperature, reservoir volume and feed gas content. (4) A preliminary design of the Kr-Xe separating plant for a reprocessing plant (1500 ton-U/yr) shows the required number of columns and the total electric power. (author)

  4. Red flags to screen for malignancy and fracture in patients with low back pain: systematic review

    DEFF Research Database (Denmark)

    Downie, A.; Williams, C.M.; Henschke, N.

    2013-01-01

    Objective: To review the evidence on diagnostic accuracy of red flag signs and symptoms to screen for fracture or malignancy in patients presenting with low back pain to primary, secondary, or tertiary care. Design: Systematic review. Data sources: Medline, OldMedline, Embase, and CINAHL from......-test probability for detection of spinal malignancy was history of malignancy (33%, 22% to 46%). Conclusions: While several red flags are endorsed in guidelines to screen for fracture or malignancy, only a small subset of these have evidence that they are indeed informative. These findings suggest a need...

  5. WE-AB-202-06: Correlating Lung CT HU with Transformation-Based and Xe-CT Derived Ventilation

    International Nuclear Information System (INIS)

    Du, K; Patton, T; Bayouth, J; Reinhardt, J; Christensen, G

    2016-01-01

    Purpose: Regional lung ventilation is useful to reduce radiation-induced function damage during lung cancer radiation therapy. Recently a new direct HU (Hounsfield unit)-based method was proposed to estimate the ventilation potential without image registration. The purpose of this study is to examine if there is a functional dependence between HU values and transformation-based or Xe-CT derived ventilation. Methods: 4DCT images acquired from 13 patients prior to radiation therapy and 4 mechanically ventilated sheep subjects which also have associated Xe-CT images were used for this analysis. Transformation-based ventilation was computed using Jacobian determinant of the transformation field between peak-exhale and peak-inhale 4DCT images. Both transformation and Xe-CT derived ventilation was computed for each HU bin. Color scatter plot and cumulative histogram were used to compare and validate the direct HU-based method. Results: There was little change of the center and shape of the HU histograms between free breathing CT and 4DCT average, with or without smoothing, and between the repeated 4DCT scans. HU of −750 and −630 were found to have the greatest transformation-based ventilation for human and sheep subjects, respectively. Maximum Xe-CT derived ventilation was found to locate at HU of −600 in sheep subjects. The curve between Xe-CT ventilation and HU was noisy for tissue above HU −400, possibly due to less intensity change of Xe gas during wash-out and wash-in phases. Conclusion: Both transformation-based and Xe-CT ventilation demonstrated that lung tissues with HU values in the range of (-750, −600) HU have the maximum ventilation potential. The correlation between HU and ventilation suggests that HU might be used to help guide the ventilation calculation and make it more robust to noise and image registration errors. Research support from NIH grants CA166703 and CA166119 and a gift from Roger Koch.

  6. WE-AB-202-06: Correlating Lung CT HU with Transformation-Based and Xe-CT Derived Ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Du, K; Patton, T; Bayouth, J [University of Wisconsin, Madison, WI (United States); Reinhardt, J; Christensen, G [The University of Iowa, Iowa City, IA (United States)

    2016-06-15

    Purpose: Regional lung ventilation is useful to reduce radiation-induced function damage during lung cancer radiation therapy. Recently a new direct HU (Hounsfield unit)-based method was proposed to estimate the ventilation potential without image registration. The purpose of this study is to examine if there is a functional dependence between HU values and transformation-based or Xe-CT derived ventilation. Methods: 4DCT images acquired from 13 patients prior to radiation therapy and 4 mechanically ventilated sheep subjects which also have associated Xe-CT images were used for this analysis. Transformation-based ventilation was computed using Jacobian determinant of the transformation field between peak-exhale and peak-inhale 4DCT images. Both transformation and Xe-CT derived ventilation was computed for each HU bin. Color scatter plot and cumulative histogram were used to compare and validate the direct HU-based method. Results: There was little change of the center and shape of the HU histograms between free breathing CT and 4DCT average, with or without smoothing, and between the repeated 4DCT scans. HU of −750 and −630 were found to have the greatest transformation-based ventilation for human and sheep subjects, respectively. Maximum Xe-CT derived ventilation was found to locate at HU of −600 in sheep subjects. The curve between Xe-CT ventilation and HU was noisy for tissue above HU −400, possibly due to less intensity change of Xe gas during wash-out and wash-in phases. Conclusion: Both transformation-based and Xe-CT ventilation demonstrated that lung tissues with HU values in the range of (-750, −600) HU have the maximum ventilation potential. The correlation between HU and ventilation suggests that HU might be used to help guide the ventilation calculation and make it more robust to noise and image registration errors. Research support from NIH grants CA166703 and CA166119 and a gift from Roger Koch.

  7. Worker flag. Independent Electrical Policy

    International Nuclear Information System (INIS)

    Bahen, D.

    2000-01-01

    This work analyses the initiative of privatization of the Mexican Electric Industry and also it is showed the incoherence of this mistaken proposal. Along the same line is analysed tthe situation of the National Electric Sector and the working process for the distinct types of electric generation just as the syndical and labor situations. In consequence it is proposed an Independent Electrical Policy, which includes the integration of the Nationalized Electric Industry, the syndical union and the Unique Collective Contract. The purpose of this work is to contribute to the success of the electrical and nuclear struggle always maintaining in rising position the red flag of the proletariat. The author considers that the privatization means mercantilization of the human necessities. The privatization is not inevitable at condition of to exercise consequently the political actions necessary through alternatives includes: the worker control of production, research, and the National Electric strike. (Author)

  8. Electrical and chemical properties of XeCl*(308 nm) exciplex lamp created by a dielectric barrier discharge

    Energy Technology Data Exchange (ETDEWEB)

    Baadj, S.; Harrache, Z., E-mail: zharrache@yahoo.com; Belasri, A. [Université des Sciences et de la Technologie d’Oran, USTO-MB, Laboratoire de Physique des Plasmas, Matériaux Conducteurs et leurs Application (LPPMCA) (Algeria)

    2013-12-15

    The aim of this work is to highlight, through numerical modeling, the chemical and the electrical characteristics of xenon chloride mixture in XeCl* (308 nm) excimer lamp created by a dielectric barrier discharge. A temporal model, based on the Xe/Cl{sub 2} mixture chemistry, the circuit and the Boltzmann equations, is constructed. The effects of operating voltage, Cl{sub 2} percentage in the Xe/Cl{sub 2} gas mixture, dielectric capacitance, as well as gas pressure on the 308-nm photon generation, under typical experimental operating conditions, have been investigated and discussed. The importance of charged and excited species, including the major electronic and ionic processes, is also demonstrated. The present calculations show clearly that the model predicts the optimal operating conditions and describes the electrical and chemical properties of the XeCl* exciplex lamp.

  9. Influence of the chlorine concentration on the radiation efficiency of a XeCl exciplex lamp

    Energy Technology Data Exchange (ETDEWEB)

    Avtaeva, S. V., E-mail: s_avtaeva@mail.ru [Kyrgyz-Russian Slavic University (Kyrgyzstan); Sosnin, E. A. [Russian Academy of Sciences, Institute of High-Current Electronics, Siberian Branch (Russian Federation); Saghi, B. [Mohamed Boudiaf University of Sciences and Technology, Department of Electronics (Algeria); Panarin, V. A. [Russian Academy of Sciences, Institute of High-Current Electronics, Siberian Branch (Russian Federation); Rahmani, B. [Mohamed Boudiaf University of Sciences and Technology, Department of Electronics (Algeria)

    2013-09-15

    The influence of the chlorine concentration on the radiation efficiency of coaxial exciplex lamps (excilamps) excited by a dielectric barrier discharge (DBD) in binary Xe-Cl{sub 2} mixtures at pressures of 240–250 Torr is investigated experimentally and theoretically. The experiments were carried out at Cl{sub 2} concentrations in the range of 0.01–1%. The DBD characteristics were calculated in the framework of a one-dimensional hydrodynamic model at Cl{sub 2} concentrations in the range of 0.1–5%. It is found that the radiation intensities of the emission bands of Xe*{sub 2}(172 nm) and XeCl* (308 nm) are comparable when the chlorine concentration in the mixture is in the range of 0.01–0.1%. In this case, in the mixture, the radiation intensity of the Xe*{sub 2} molecule rapidly decreases with increasing Cl{sub 2} concentration and, at a chlorine concentration of ≥0.2%, the radiation of the B → X band of XeCl* molecules with a peak at 308 nm dominates in the discharge radiation. The radiation efficiency of this band reaches its maximum value at chlorine concentrations in the range of 0.4–0.5%. The calculated efficiencies of DBD radiation exceed those obtained experimentally. This is due to limitations of the one-dimensional model, which assumes the discharge to be uniform in the transverse direction, whereas the actual excilamp discharge is highly inhomogeneous. The influence of the chlorine concentration on the properties of the DBD plasma in binary Xe-Cl{sub 2} mixtures is studied numerically. It is shown that an increase in the Cl{sub 2} concentration in the mixture leads to the attachment of electrons to chlorine atoms and a decrease in the electron density and discharge conductivity. As a result, the electric field and the voltage drop across the discharge gap increase, which, in turn, leads to an increase in the average electron energy and the probability of dissociation of Cl{sub 2} molecules and ionization of Xe atoms and Cl{sub 2} molecules

  10. Influence of the chlorine concentration on the radiation efficiency of a XeCl exciplex lamp

    International Nuclear Information System (INIS)

    Avtaeva, S. V.; Sosnin, E. A.; Saghi, B.; Panarin, V. A.; Rahmani, B.

    2013-01-01

    The influence of the chlorine concentration on the radiation efficiency of coaxial exciplex lamps (excilamps) excited by a dielectric barrier discharge (DBD) in binary Xe-Cl 2 mixtures at pressures of 240–250 Torr is investigated experimentally and theoretically. The experiments were carried out at Cl 2 concentrations in the range of 0.01–1%. The DBD characteristics were calculated in the framework of a one-dimensional hydrodynamic model at Cl 2 concentrations in the range of 0.1–5%. It is found that the radiation intensities of the emission bands of Xe* 2 (172 nm) and XeCl* (308 nm) are comparable when the chlorine concentration in the mixture is in the range of 0.01–0.1%. In this case, in the mixture, the radiation intensity of the Xe* 2 molecule rapidly decreases with increasing Cl 2 concentration and, at a chlorine concentration of ≥0.2%, the radiation of the B → X band of XeCl* molecules with a peak at 308 nm dominates in the discharge radiation. The radiation efficiency of this band reaches its maximum value at chlorine concentrations in the range of 0.4–0.5%. The calculated efficiencies of DBD radiation exceed those obtained experimentally. This is due to limitations of the one-dimensional model, which assumes the discharge to be uniform in the transverse direction, whereas the actual excilamp discharge is highly inhomogeneous. The influence of the chlorine concentration on the properties of the DBD plasma in binary Xe-Cl 2 mixtures is studied numerically. It is shown that an increase in the Cl 2 concentration in the mixture leads to the attachment of electrons to chlorine atoms and a decrease in the electron density and discharge conductivity. As a result, the electric field and the voltage drop across the discharge gap increase, which, in turn, leads to an increase in the average electron energy and the probability of dissociation of Cl 2 molecules and ionization of Xe atoms and Cl 2 molecules. The total energy deposited in the discharge

  11. Influence of the chlorine concentration on the radiation efficiency of a XeCl exciplex lamp

    Science.gov (United States)

    Avtaeva, S. V.; Sosnin, E. A.; Saghi, B.; Panarin, V. A.; Rahmani, B.

    2013-09-01

    The influence of the chlorine concentration on the radiation efficiency of coaxial exciplex lamps (excilamps) excited by a dielectric barrier discharge (DBD) in binary Xe-Cl2 mixtures at pressures of 240-250 Torr is investigated experimentally and theoretically. The experiments were carried out at Cl2 concentrations in the range of 0.01-1%. The DBD characteristics were calculated in the framework of a one-dimensional hydrodynamic model at Cl2 concentrations in the range of 0.1-5%. It is found that the radiation intensities of the emission bands of Xe*2(172 nm) and XeCl* (308 nm) are comparable when the chlorine concentration in the mixture is in the range of 0.01-0.1%. In this case, in the mixture, the radiation intensity of the Xe*2 molecule rapidly decreases with increasing Cl2 concentration and, at a chlorine concentration of ≥0.2%, the radiation of the B → X band of XeCl* molecules with a peak at 308 nm dominates in the discharge radiation. The radiation efficiency of this band reaches its maximum value at chlorine concentrations in the range of 0.4-0.5%. The calculated efficiencies of DBD radiation exceed those obtained experimentally. This is due to limitations of the one-dimensional model, which assumes the discharge to be uniform in the transverse direction, whereas the actual excilamp discharge is highly inhomogeneous. The influence of the chlorine concentration on the properties of the DBD plasma in binary Xe-Cl2 mixtures is studied numerically. It is shown that an increase in the Cl2 concentration in the mixture leads to the attachment of electrons to chlorine atoms and a decrease in the electron density and discharge conductivity. As a result, the electric field and the voltage drop across the discharge gap increase, which, in turn, leads to an increase in the average electron energy and the probability of dissociation of Cl2 molecules and ionization of Xe atoms and Cl2 molecules. The total energy deposited in the discharge rises with increasing

  12. Synthesis of new host molecules and applications for imaging by NMR Xe

    International Nuclear Information System (INIS)

    Traore, T.

    2011-01-01

    Magnetic Resonance Imaging (MRI) is widely used today for early medical diagnosis. During the MRI examination, the use of contrast agent allows the obtention of well resolved images. However the lack of sensibility of this technic lead to the utilization of hyper-polarized species ( 3 He, 13 C, 129 Xe) in MRI. The xenon (Xe) is the more promising but due to its weak selectivity, it cannot be used in molecular imaging. So, the development and utilization of host molecules able to encapsulate the xenon and bring it to a targeted biological tissue or organ is necessary. In these conditions, during this thesis, we worked on the elaboration of such molecules, and particularly, in cryptophanes since these compounds have strong affinity for xenon and could be used as tools for MRI by hyper-polarized xenon (Hp Xe). A new route synthesis of cryptophane-111, that has the highest affinity for xenon, was developed; first functionalized derivatives of this compound have been also obtained in order to obtain the first biosensors based on cryptophane-111. The coating of specific ligand on these functionalized compounds could allow targeted MRI. A probe for hydrogen peroxide (H 2 O 2 ) detection was synthesized. Hydrogen peroxide is implicated in cellular oxidative stress and present in case of neuro-degenerative diseases (Parkinson, Alzheimer). The probe obtained allowed the imaging of H 2 O 2 by MRI Xe for the first time. nano-tubes functionalized with strong concentration of cryptophane have been synthesized in order to increase the sensitivity of the imaging technic that uses xenon. (author) [fr

  13. Effects of acute and chronic exposure to both 900 MHz and 2100 MHz electromagnetic radiation on glutamate receptor signaling pathway.

    Science.gov (United States)

    Gökçek-Saraç, Çiğdem; Er, Hakan; Kencebay Manas, Ceren; Kantar Gok, Deniz; Özen, Şükrü; Derin, Narin

    2017-09-01

    To demonstrate the molecular effects of acute and chronic exposure to both 900 and 2100 MHz radiofrequency electromagnetic radiation (RF-EMR) on the hippocampal level/activity of some of the enzymes - including PKA, CaMKIIα, CREB, and p44/42 MAPK - from N-methyl-D-aspartate receptor (NMDAR)-related signaling pathways. Rats were divided into the following groups: sham rats, and rats exposed to 900 and 2100 MHz RF-EMR for 2 h/day for acute (1 week) or chronic (10 weeks), respectively. Western blotting and activity measurement assays were used to assess the level/activity of the selected enzymes. The obtained results revealed that the hippocampal level/activity of selected enzymes was significantly higher in the chronic groups as compared to the acute groups at both 900 and 2100 MHz RF-EMR exposure. In addition, hippocampal level/activity of selected enzymes was significantly higher at 2100 MHz RF-EMR than 900 MHz RF-EMR in both acute and chronic groups. The present study provides experimental evidence that both exposure duration (1 week versus 10 weeks) and different carrier frequencies (900 vs. 2100 MHz) had different effects on the protein expression of hippocampus in Wistar rats, which might encourage further research on protection against RF-EMR exposure.

  14. (e, 2e) processes on Ne, Ar and Xe targets

    Energy Technology Data Exchange (ETDEWEB)

    Purohit, G; Patidar, Vinod; Sud, K K, E-mail: g_vpurohit@yahoo.co, E-mail: ghanshyam.purohit@spsu.ac.i [Department of Physics, School of Engineering, Sir Padampat Singhania University, Bhatewar, Udaipur-313 601 (India)

    2010-06-01

    Recently, there have been several attempts to explain the features of triple differential cross section (TDCS) for the (e, 2e) processes on inert targets Ne, Ar and Xe but there are still certain discrepancies in theoretical results and measurements, which require more theoretical efforts to understand the collision dynamics of these targets. We present in this paper the results of our modified distorted wave Born approximation (DWBA) calculation of TDCS for the ionization of Ne (2p), Ar (3p) and Xe (5p) targets. We modify the standard DWBA formalism by including the correlation-polarization potential (which is function of electron density) and compare our computed results with the available experimental and theoretical data. We observe that the polarization potential is able to improve the agreement with experimental results.

  15. Red flags in children with chronic abdominal pain and Crohn's disease-a single center experience.

    Science.gov (United States)

    El-Chammas, Khalil; Majeskie, Angela; Simpson, Pippa; Sood, Manu; Miranda, Adrian

    2013-04-01

    To compare history and symptoms at initial presentation of patients with chronic abdominal pain (CAP) and Crohn's disease (CD). Red flags are used to help determine which patients with CAP are likely to have an underlying disease such as CD. However, red flags have not been validated and pediatric studies are lacking. Patients seen in the outpatient Pediatric Gastroenterology Clinic at Children's Hospital of Wisconsin between 2005 and 2008 prospectively completed a demographic, history, and symptom questionnaire. Patients with abdominal pain for at least 1 month and no evidence of organic disease were compared with patients diagnosed with CD confirmed by mucosal biopsies. Data were collected on 606 patients (128 with CD and 478 with functional gastrointestinal disorders). Patients with functional gastrointestinal disorders had more stressors (P pain were no different between groups. Anemia, hematochezia, and weight loss were most predictive of CD (cumulative sensitivity of 94%). The presence of anemia, hematochezia, and weight loss help identify patients with CAP who require further work-up and referral to a pediatric gastroenterologist. Furthermore, waking from sleep or joint pain occurred similarly between groups and should not be considered as "red flags." Copyright © 2013. Published by Mosby, Inc.

  16. GeoGebra and eXe Learning: applicability in the teaching of Physics and Mathematics

    Directory of Open Access Journals (Sweden)

    Eunice Maria Mussoi

    2011-04-01

    Full Text Available Today, education in the field of sciences is still characterized by excessive attention to repetitive exercises at the expense of understanding and visualizing the concepts of mathematical and physical phenomena. This article will show the potential of the software GeoGebra to build content and / or activities in Physics and Mathematics usable in isolation or engaged in other activities, such as eXe Learning. For this we constructed two activities: a mathematical content - Application of successive derivatives, and a content of physics - Application of uniform rectilinear motion. These contents were built in eXe Learning, and the graphics was built in GeoGebra and imported into the eXe by Java Applet. The content was done with the exported SCORM to Moodle, it is within this framework that the student will study the movement and display of graphic content.

  17. Test of Lorentz symmetry with a 3He/129Xe clock-comparison experiment

    International Nuclear Information System (INIS)

    Gemmel, Claudia

    2011-01-01

    The minimal Standard Model Extension (SME) of Kostelecky and coworkers, which parametrizes the general treatment of CPT- and Lorentz invariance violation, predicts sidereal modulations of atomic transition frequencies as the Earth rotates relative to a Lorentz-violating background field. One method to search for these modulations is the so-called clock-comparison experiment, where the frequencies of co-located clocks are compared as they rotate with respect to the fixed stars. In this work an experiment is presented where polarized 3 He and 129 Xe gas samples in a glass cell serve as clocks, whose nuclear spin precession frequencies are detected with the help of highly sensitive SQUID sensors inside a magnetically shielded room. The unique feature of this experiment is the fact that the spins are precessing freely, with transverse relaxation times T * 2 of up to 4.4 h for 129 Xe and 14.1 h for 3 He. To be sensitive to Lorentz-violating effects, the influence of external magnetic fields is canceled via the weighted 3 He/ 129 Xe phase difference, ΔΦ=Φ he -(γ he )/(γ xe ) Φ xe . The Lorentz-violating SME parameters for the neutron, b n X and b n Y , are determined out of a χ 2 fit on the phase difference data of 7 spin precession measurements of 12 to 16 hours length. The piecewise defined fit model contains a sine and a cosine term to describe the sidereal modulation, as well as 7 offset terms, 7 linear terms and 7 . 2 exponential terms decreasing with T * 2,he and T * 2,xe , which are assigned to the respective measurement. The linear term in the weighted phase difference mainly arises from deviations of the gyromagnetic ratios from their literature values due to chemical shifts, while the exponential terms reflect the phase shifts resulting from demagnetization fields in the non-ideally spherical sample cell. The result of the χ 2 fit constrains the parameter b n perpendicular to =√((b n X ) 2 +(b n Y ) 2 ) to be -32 GeV at the 95% confidence level. This

  18. Angular distribution of Xe 5s→epsilonp photoelectrons: Disagreement between experiment and theory

    International Nuclear Information System (INIS)

    Fahlman, A.; Carlson, T.A.; Krause, M.O.

    1983-01-01

    The angular asymmetry parameter β for the Xe 5s→epsilonp photoelectrons has been studied with use of synchrotron radiation (hν = 28--65 eV). The present results show that the relativistic random-phase approximation theory does not satisfactorily describe the Xe 5s photoionization process close to the Cooper minimum and thus require a renewed theoretical approach. The 5s partial photoionization cross section was obtained over the same photon region and the results agree with experimental values found in the literature

  19. New limit on rate of 2ν ββ decay of 136Xe

    International Nuclear Information System (INIS)

    Kuzminov, V.V.; Lobashev, V.M.; Novikov, V.M.; Ovchinnikov, B.M.; Pomansky, A.A.; Pritychenko, B.V.

    1991-01-01

    A significant background suppression was achieved in a new step of measurements in the Baksan underground laboratory 136 Xe ββ experiment, using a high-pressure gridded ionization chamber. In order to reduce outer γ-ray background, the chamber was placed inside the passive shielding consisting of 15 cm of lead and of 10 cm of copper. Half-life limit of 2.7x10 20 yrs is obtained for 2ν ββ mode of 136 Xe. (R.P.) 12 refs., 2 figs

  20. Constructing and Validating the Foreign Language Attitudes and Goals Survey (FLAGS)

    Science.gov (United States)

    Cid, Eva; Granena, Gisela; Tragant, Elsa

    2009-01-01

    The present study describes the process that was followed in the construction and validation of the foreign language attitudes and goals survey (FLAGS), a new questionnaire based on qualitative data from Tragant and Munoz [Tragant, Munoz, C., 2000. "La motivacion y su relacion con la edad en un contexto escolar de aprendizaje de una lengua…

  1. Mucosal/submucosal blood flow in the small intestine in pigs determined by local washout of 133Xe and microsphere techniques

    DEFF Research Database (Denmark)

    Mortensen, Peter; Olsen, J; Sejrsen, P

    1990-01-01

    In 11 anaesthetized pigs a laparotomy was performed and the mucosal and submucosal blood flow rate in the small intestine of the pig was determined by a local application of 133Xe and by 6.5-microns radioactive microspheres. The 133Xe washout plotted in a semilogarithmic diagram showed a multiexp......In 11 anaesthetized pigs a laparotomy was performed and the mucosal and submucosal blood flow rate in the small intestine of the pig was determined by a local application of 133Xe and by 6.5-microns radioactive microspheres. The 133Xe washout plotted in a semilogarithmic diagram showed...

  2. Country-Level Population and Downscaled Projections Based on the SRES B2 Scenario, 1990-2100

    Data.gov (United States)

    National Aeronautics and Space Administration — The Country-Level Population and Downscaled Projections Based on Special Report on Emissions Scenarios (SRES) B2 Scenario, 1990-2100, were based on the UN 1998...

  3. A CERN flag is set to wave up in the Himalayas

    CERN Multimedia

    Roberto Cantoni

    2010-01-01

    On 18 October, Hubert Reymond, from the Industrial Controls and Engineering group of the EN Department, will be leaving to Nepal with a CERN flag in his backpack. He will place it at the highest point of his trek across the Annapurna mountains in the Himalayas, Thorong La pass, at 5,416 m above sea level.   A view of the Annapurna mountains (source: www.flickr.com/minutesalone) “Is there any official CERN flag I can carry with me during my trek through Nepal?” Some days ago, the Press Office was confronted with this unusual (but see box) question from Hubert Reymond. From 18 October to 10 November, Reymond, who works as an industrial computing engineer in the EN Department, will be trekking across the 55 km-long Annapurna massif in the Himalayas, whose highest point lies at 8,091 m (making it the 10th-highest summit in the world). The area is well-known to trekkers from around the world, as it includes several world-class circuits, including the Annapurna circuit which Reym...

  4. Radiative stabilization of double-Rydberg states formed in slow Xeq+-Xe (15 ≤ q ≤ 35) collisions

    International Nuclear Information System (INIS)

    Anderson, H.; Cederquist, H.; Astner, G.; Hvelplund, P.; Pedersen, J.O.P.

    1990-01-01

    Electron capture processes, in which the projectile charge (q) is lowered by one unit, have been recorded by means of high-resolution energy-gain spectroscopy for 4q keV Xe q+ -Xe (15 ≤ q ≤ 35) collisions. The ratios, R, between the cross sections for the transfer ionisation and single-electron capture were extracted from the measured spectra. The quantity R increases slowly for charges up to q = 25 and decreases rapidly for higher q. Relying on the extended classical over-barrier model we relate R to the branching ratio for autoionisation, F, through R = k.F, and estimate the variation in k as a function of q. On the basis of the extended classical over-barrier model we ascribe the decrease in R at high q to an increase in radiative stabilization of double-Rydberg states formed in slow Xe q+ -Xe, q > 25, collisions. (orig.)

  5. Molecular dynamic simulation of interaction of low-energy Ar and Xe ions with copper clusters at graphite surface

    International Nuclear Information System (INIS)

    Kornich, G.V.; Lozovskaya, L.I.; Betts, G.; Zaporozhchenko, V.I.; Faupel, F.

    2005-01-01

    One conducted molecular and dynamic simulation of sputtering of isolated clusters consisting of 13, 27 and 195 Cu atoms from the (0001) graphite surface by 200 eV energy Ar and Xe ions. It is shown that the factors of reflection of Ar and Xe ions from copper clusters differ from one another insignificantly, though the energy of the reflected Xe ions is essentially lower than that of Ar ions. The values of the factor of cluster sputtering by Xe ions are higher in contrast to sputtering by Ar ions. One identified two mechanisms of cluster sputtering resulting in the maximum of sputtering intensity at the polar angles near the normal one, and in periodicity of maximums within the azimuth distributions of sputtering intensity with 60 deg period [ru

  6. Enhanced electrical conductivity in Xe ion irradiated CNT based transparent conducting electrode on PET substrate

    Science.gov (United States)

    Surbhi; Sharma, Vikas; Singh, Satyavir; Garg, Priyanka; Asokan, K.; Sachdev, Kanupriya

    2018-02-01

    An investigation of MWCNT-based hybrid electrode films with improved electrical conductivity after Xe ion irradiation is reported. A multilayer hybrid structure of Ag-MWCNT layer embedded in between two ZnO layers was fabricated and evaluated, pre and post 100 keV Xe ion irradiation, for their performance as Transparent Conducting Electrode in terms of their optical and electrical properties. X-ray diffraction pattern exhibits highly c-axis oriented ZnO films with a small variation in lattice parameters with an increase in ion fluence. There is no significant change in the surface roughness of these films. Raman spectra were used to confirm the presence of CNT. The pristine multilayer films exhibit an average transmittance of ˜70% in the entire visible region and the transmittance increases with Xe ion fluence. A significant enhancement in electrical conductivity post-Xe ion irradiation viz from 1.14 × 10-7 Ω-1 cm-1 (pristine) to 7.04 × 103 Ω-1 cm-1 is seen which is due to the high connectivity in the top layer with Ag-CNT hybrid layer facilitating the smooth transfer of electrons.

  7. Performance characteristics of an excimer laser (XeCl) with single ...

    Indian Academy of Sciences (India)

    2017-01-10

    Jan 10, 2017 ... Performance characteristics of an excimer laser (XeCl) with single-stage magnetic ... the stress can increase the lifetime of the switches and ..... work. References. [1] Ying-Tung Chen, Kris Naessens, Roel Bates, Yunn-Shiuan.

  8. Determination of electron impact ionization and excitation coefficients in He-Xe gas mixtures. He-Xe kongo gas ni okeru denshi shototsu denri keisu oyobi reiki keisu no sokutei to kaiseki

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, K.; Tachibana, K. (Kyoto Inst. of Technology, Kyoto (Japan))

    1991-03-20

    The rare gas discharge gives a stable discharge and light emission characteristics at low temperature in comparison with the discharge of the vapor of such a metal as Hg. The present barrier for the commercialization of the color PDP lies in the lower level of its emission intensity and efficiency in comparison with that of CRT. In this report, an electron impact ionization coefficient in a gas mixture and an electron impact excitation coefficient for a XeIs {sub 4} level were analyzed using a Boltzmann equation by means of a steady state Townsend method using a drift tube. By comparing both, the elementary process in the gas mixture is investiagted to discuss the respective contributions for the effective ionization coefficient and the excitation coefficient. As a result, it was found that the ionization process in the He-Xe gas mixture could be described by the processes of direct ionization of Xe and He, and an indirect ionization (Penning effect) by an active helium. 37 refs., 12 figs.

  9. Search for neutrinoless double beta decay in {sup 136}Xe with EXO-200

    Energy Technology Data Exchange (ETDEWEB)

    Feldmeier, Wolfhart

    2015-02-19

    Several properties of neutrinos, such as their absolute mass, their possible Majorana nature or the mechanisms that lead to small neutrino masses, are still unknown. The EXO-200 experiment is trying to answer some of these questions by searching for the hypothetical neutrinoless double beta decay of the isotope {sup 136}Xe. This thesis describes an analysis of two years of detector data, which yields a lower limit on the half-life of neutrinoless double beta decay of {sup 136}Xe of 1.1 x 10{sup 25} years.

  10. Observation of Two-Neutrino Double-Beta Decay in Xe-136 with EXO-200

    Energy Technology Data Exchange (ETDEWEB)

    Ackerman, N.; /SLAC; Aharmim, B.; /Laurentian U.; Auger, M.; /Bern U.; Auty, D.J.; /Alabama U.; Barbeau, P.S.; Barry, K.; Bartoszek, L.; /Stanford U., Phys. Dept.; Beauchamp, E.; /Laurentian U.; Belov, V.; /Moscow, ITEP; Benitez-Medina, C.; /Colorado State U.; Breidenbach, M.; /SLAC; Burenkov, A.; /Moscow, ITEP; Cleveland, B.; /Laurentian U.; Conley, R.; Conti, E.; /SLAC; Cook, J.; /Massachusetts U., Amherst; Cook, S.; /Colorado State U.; Coppens, A.; /Carleton U.; Counts, I.; /Stanford U., Phys. Dept.; Craddock, W.; /SLAC; Daniels, T.; /Massachusetts U., Amherst /Moscow, ITEP /Maryland U. /Stanford U., Phys. Dept. /Alabama U. /Maryland U. /Moscow, ITEP /Stanford U., Phys. Dept. /Laurentian U. /Carleton U. /Colorado State U. /Laurentian U. /Munich, Tech. U. /Bern U. /SLAC /Bern U. /Carleton U. /Stanford U., Phys. Dept. /Carleton U. /Maryland U. /Colorado State U. /SLAC /Carleton U. /SLAC /Alabama U. /SLAC /Moscow, ITEP /Indiana U. /Stanford U., Phys. Dept. /Moscow, ITEP /Stanford U., Phys. Dept. /Massachusetts U., Amherst /Seoul U. /Carleton U. /Stanford U., Phys. Dept.; /more authors..

    2012-09-14

    We report the observation of two-neutrino double-beta decay in {sup 136}Xe with T{sub 1/2} = 2.11 {+-} 0.04(stat) {+-} 0.21(syst) x 10{sup 21} yr. This second-order process, predicted by the standard model, has been observed for several nuclei but not for {sup 136}Xe. The observed decay rate provides new input to matrix element calculations and to the search for the more interesting neutrinoless double-beta decay, the most sensitive probe for the existence of Majorana particles and the measurement of the neutrino mass scale.

  11. A novel Cs-(129)Xe atomic spin gyroscope with closed-loop Faraday modulation.

    Science.gov (United States)

    Fang, Jiancheng; Wan, Shuangai; Qin, Jie; Zhang, Chen; Quan, Wei; Yuan, Heng; Dong, Haifeng

    2013-08-01

    We report a novel Cs-(129)Xe atomic spin gyroscope (ASG) with closed-loop Faraday modulation method. This ASG requires approximately 30 min to start-up and 110 °C to operate. A closed-loop Faraday modulation method for measurement of the optical rotation was used in this ASG. This method uses an additional Faraday modulator to suppress the laser intensity fluctuation and Faraday modulator thermal induced fluctuation. We theoretically and experimentally validate this method in the Cs-(129)Xe ASG and achieved a bias stability of approximately 3.25 °∕h.

  12. Search for 136Xe neutrinoless double beta decay with the Enriched Xenon Observatory (EXO)

    International Nuclear Information System (INIS)

    Giroux, G.

    2014-01-01

    The EXO collaboration is searching for the neutrinoless double beta decay of 136 Xe. Such observation would determine an absolute mass scale for the neutrinos, establish their Majorana nature, and uncover physics beyond the Standard Model. The EXO-200 detector is a single phase liquid xenon ultra low background TPC (Time Projection Chamber), with an active mass of 110 kg of 80.6% enriched xenon in the isotope 136. The detector is currently operating at the WIPP site and has been collecting data with enriched xenon since May 2011. The data collected give a lower limit for the neutrinoless double beta decay half-life of 136 Xe: T > 1.6*10 25 years at 90% C.L. The same data give a lower limit for the 2 neutrinos double beta decay of 136 Xe: T > 2.23*10 21 years that agrees with experimental values found in the literature

  13. Experimental preparation of Kr/Xe hydrate at pressures up to 160 bar

    International Nuclear Information System (INIS)

    Simonis, R.

    1985-06-01

    A compound called gas (mixture) hydrate is formed under pressurized atmosphere by reaction of krypton, xenon and a mixture of both with water. The study under review reports on preparing such hydrates experimentally under pressures up to 160 bar. The dissociation function of the hydrates is determined by low and medium-pressure experiments. Observing the formation process it was found that a hydrate layer is formed at the interface of gas and water, its separating effect almost inhibiting continuance of hydrate reactions. Strong stirring will avoid or destroy the separating layer. It is shown that at pressures above 50 bar the dissociation function psub(D) (T) gets non-linear with logarithmic pressure plotting above the absolute, reciprocal temperature. The medium-temperature experiments show that the density of the gas consisting of Xe or Kr and Xe, respectively, reaches higher values than that of the water. In this case, the system collapses and the gas is found at the bottom of the pressure flask, and the water in the top region. The gas samples taken during the mixed hydrate preparation show that Kr is accumulated in the gaseous phase, and Xe in the hydrate phase. (orig./RB) [de

  14. Cluster-surface collisions: Characteristics of Xe55- and C20 - Si[111] surface bombardment

    International Nuclear Information System (INIS)

    Cheng, H.

    1999-01-01

    Molecular dynamics (MD) simulations are performed to study the cluster-surface collision processes. Two types of clusters, Xe 55 and C 20 are used as case studies of materials with very different properties. In studies of Xe 55 - Si[111] surface bombardment, two initial velocities, 5.0 and 10.0 km/s (normal to the surface) are chosen to investigate the dynamical consequences of the initial energy or velocity in the cluster-surface impact. A transition in the speed of kinetic energy propagation, from subsonic velocities to supersonic velocities, is observed. Energy transfer, from cluster translational motion to the substrate, occurs at an extremely fast rate that increases as the incident velocity increases. Local melting and amorphous layer formation in the surfaces are found via energetic analysis of individual silicon atoms. For C 20 , the initial velocity ranges from 10 to 100 km/s. The clusters are damaged immediately upon impact. Similar to Xe 55 , increase in the potential energy is larger than the increase in internal kinetic energy. However, the patterns of energy distribution are different for the two types of clusters. The energy transfer from the carbon clusters to Si(111) surface is found to be slower than that found in the Xe clusters. Fragmentation of the carbon cluster occurs when the initial velocity is greater than 30 km/s. At 10 km/s, the clusters show recrystallization at later times. The average penetration depth displays a nonlinear dependence on the initial velocity. Disturbance in the surface caused by C 20 is discussed and compared to the damage caused by Xe 55 . Energetics, structures, and dynamics of these systems are fully analyzed and characterized. copyright 1999 American Institute of Physics

  15. Radiation stability of nanocrystalline ZrN coatings irradiated with high energy Xe and Bi ions

    International Nuclear Information System (INIS)

    Skuratov, V.A.; Sokhatsky, A.S.; Uglov, V.V.; Zlotski, S.V.; Van Vuuren, A.J.; Neethling, Jan; O'Connell, J.

    2011-01-01

    Swift Xe and Bi ion irradiation effects in nanocrystalline ZrN coatings as a function of ion fluence are reported. Zirconium nitride films of different thickness (0.1, 3, 10 and 20 micrometers) synthesized by vacuum arc-vapour deposition in nanocrystalline state (average size of crystallites is ∼4 nm) were irradiated with 167 MeV Xe and 695 MeV Bi ions to fluences in the range 3x10 12 ÷2.6x10 15 cm -2 (Xe) and 10 12 x10 13 cm -2 (Bi) and studied using XRD and TEM techniques. No evidence of amorphization due to high level ionizing energy losses has been found. The measurements of lattice parameter have revealed nonmonotonic dependence of the stress level in irradiated samples on ion fluence. (authors)

  16. Phloem Transport Of Arsenic Species From Flag Leaf To Grain During Grain Filling

    Science.gov (United States)

    Strategies to reduce arsenic (As) in rice grain, below concentrations that represent a serious human health concern, require that the mechanisms of As accumulation within grain be established. Therefore, retranslocation of As species from flag leaves into filling rice grain was ...

  17. Effects of Xe Gas Content and Total Gas Pressure on the Discharge Characteristics of Colour Plasma Display Panels

    International Nuclear Information System (INIS)

    Hu Wenbo; Han Mengju; Liang Zhihu

    2006-01-01

    The effects of the Xe gas content and total gas pressure on the discharge characteristics of colour plasma display panels including the sustaining voltage margin, white-field chromaticity, discharge time lag (DTL), discharge current peak, and full-width-at-half-maximum (FWHM) of the discharge current pulse, are experimentally studied. The results indicate that as the Xe gas content in the He-Ne-Xe gas mixture or total pressure increases, the sustaining voltage margin increases, the white-field chromaticity improves, and the discharge current peak has a maximum value, while DTL and FWHM have a minimum value. The mean electron energy in the gas mixture discharge is also calculated through a numerical solution of Boltzmann equation. The experimental results are explained from a view of the mean electron energy variations with the Xe gas content and total gas pressure

  18. Generator Coordinate Method Analysis of Xe and Ba Isotopes

    Science.gov (United States)

    Higashiyama, Koji; Yoshinaga, Naotaka; Teruya, Eri

    Nuclear structure of Xe and Ba isotopes is studied in terms of the quantum-number projected generator coordinate method (GCM). The GCM reproduces well the energy levels of high-spin states as well as low-lying states. The structure of the low-lying states is analyzed through the GCM wave functions.

  19. Superficial Velocity Effects on HZ-PAN and AgZ-PAN for Kr/Xe Capture

    Energy Technology Data Exchange (ETDEWEB)

    Welty, Amy Keil [Idaho National Lab. (INL), Idaho Falls, ID (United States); Garn, Troy Gerry [Idaho National Lab. (INL), Idaho Falls, ID (United States); Greenhalgh, Mitchell Randy [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-04-01

    Nearly all previous testing of HZ-PAN and AgZ-PAN was conducted at the same flow rate in order to maintain consistency among tests. This testing was sufficient for sorbent capacity determinations, but did not ensure that sorbents were capable of functioning under a range of flow regimes. Tests were conducted on both HZ-PAN and AgZ-PAN at superficial velocities between 20 and 700 cm/min. For HZ-PAN, Kr capacity increased from 60 mmol/kg to 110 mmol/kg as superficial velocity increased from 21 to 679 cm/min. Results for AgZ-PAN were similar, with capacity ranging from 72 to 124 mmol/kg over the same range of superficial. These results are promising for scaling up to process flows, demonstrating flexibility to operate in a broad range of superficial velocities while maintaining sorbent capacity. While preparing for superficial velocity testing it was also discovered that AgZ-PAN Xe capacity, previously observed to diminish over time, could be recovered with increased desorption temperature. Further, a substantial Xe capacity increase was observed. Previous room temperature capacities in the range of 22-25 mmol Xe/kg AgZ-PAN were increased to over 60 mmol Xe/kg AgZ-PAN. While this finding has not yet been fully explored to optimize activation and desorption temperatures, it is encouraging.

  20. Cryogenics free production of hyperpolarized 129Xe and 83Kr for biomedical MRI applications

    Science.gov (United States)

    Hughes-Riley, Theodore; Six, Joseph S.; Lilburn, David M. L.; Stupic, Karl F.; Dorkes, Alan C.; Shaw, Dominick E.; Pavlovskaya, Galina E.; Meersmann, Thomas

    2013-12-01

    As an alternative to cryogenic gas handling, hyperpolarized (hp) gas mixtures were extracted directly from the spin exchange optical pumping (SEOP) process through expansion followed by compression to ambient pressure for biomedical MRI applications. The omission of cryogenic gas separation generally requires the usage of high xenon or krypton concentrations at low SEOP gas pressures to generate hp 129Xe or hp 83Kr with sufficient MR signal intensity for imaging applications. Two different extraction schemes for the hp gasses were explored with focus on the preservation of the nuclear spin polarization. It was found that an extraction scheme based on an inflatable, pressure controlled balloon is sufficient for hp 129Xe handling, while 83Kr can efficiently be extracted through a single cycle piston pump. The extraction methods were tested for ex vivo MRI applications with excised rat lungs. Precise mixing of the hp gases with oxygen, which may be of interest for potential in vivo applications, was accomplished during the extraction process using a piston pump. The 83Kr bulk gas phase T1 relaxation in the mixtures containing more than approximately 1% O2 was found to be slower than that of 129Xe in corresponding mixtures. The experimental setup also facilitated 129Xe T1 relaxation measurements as a function of O2 concentration within excised lungs.

  1. Cryogenics free production of hyperpolarized 129Xe and 83Kr for biomedical MRI applications☆

    Science.gov (United States)

    Hughes-Riley, Theodore; Six, Joseph S.; Lilburn, David M.L.; Stupic, Karl F.; Dorkes, Alan C.; Shaw, Dominick E.; Pavlovskaya, Galina E.; Meersmann, Thomas

    2013-01-01

    As an alternative to cryogenic gas handling, hyperpolarized (hp) gas mixtures were extracted directly from the spin exchange optical pumping (SEOP) process through expansion followed by compression to ambient pressure for biomedical MRI applications. The omission of cryogenic gas separation generally requires the usage of high xenon or krypton concentrations at low SEOP gas pressures to generate hp 129Xe or hp 83Kr with sufficient MR signal intensity for imaging applications. Two different extraction schemes for the hp gasses were explored with focus on the preservation of the nuclear spin polarization. It was found that an extraction scheme based on an inflatable, pressure controlled balloon is sufficient for hp 129Xe handling, while 83Kr can efficiently be extracted through a single cycle piston pump. The extraction methods were tested for ex vivo MRI applications with excised rat lungs. Precise mixing of the hp gases with oxygen, which may be of interest for potential in vivo applications, was accomplished during the extraction process using a piston pump. The 83Kr bulk gas phase T1 relaxation in the mixtures containing more than approximately 1% O2 was found to be slower than that of 129Xe in corresponding mixtures. The experimental setup also facilitated 129Xe T1 relaxation measurements as a function of O2 concentration within excised lungs. PMID:24135800

  2. First hoisting of the Portuguese flag at CERN

    CERN Multimedia

    Unknown, Unknown

    1986-01-01

    First hoisting of the Portuguese flag at CERN, following the country's membership. Photo taken on January 22 (or 23), 1986. From left to right: António Costa Lobo (Portugal's ambassador to the UN in Geneva), Gaspar Barreira, Karin Wall (José Mariano Gago's wife), José Mariano Gago (Portugal's JNICT president), Catarina Wall Gago (José Mariano Gago's daughter), João Varela, Herwig Schopper (CERN's Director-General), Eduardo Arantes e Oliveira (Portugal's Secretary of State for Science), , Margarida Nesbitt Rebelo, , Mário Pimenta, , Gustavo Castelo Branco, João Seixas, Sérgio Ramos, and Peter Sonderegger.

  3. Photoionisation study of Xe.CF{sub 4} and Kr.CF{sub 4} van-der-Waals molecules

    Energy Technology Data Exchange (ETDEWEB)

    Alekseev, V. A., E-mail: alekseev@va3474.spb.edu; Kevorkyants, R. [St. Petersburg State University, 7/9 Universitetskaya Nab., St. Petersburg 199034 (Russian Federation); Garcia, G. A.; Nahon, L. [Synchrotron Soleil, Orme des Merisiers, St. Aubin BP 48, 91192 Gif sur Yvette Cedex (France)

    2016-05-14

    We report on photoionization studies of Xe.CF{sub 4} and Kr.CF{sub 4} van-der-Waals complexes produced in a supersonic expansion and detected using synchrotron radiation and photoelectron-photoion coincidence techniques. The ionization potential of CF{sub 4} is larger than those of the Xe and Kr atoms and the ground state of the Rg.CF{sub 4}{sup +} ion correlates with Rg{sup +} ({sup 2}P{sub 3/2}) + CF{sub 4}. The onset of the Rg.CF{sub 4}{sup +} signals was found to be only ∼0.2 eV below the Rg ionization potential. In agreement with experiment, complementary ab initio calculations show that vertical transitions originating from the potential minimum of the ground state of Rg.CF{sub 4} terminate at a part of the potential energy surfaces of Rg.CF{sub 4}{sup +}, which are approximately 0.05 eV below the Rg{sup +} ({sup 2}P{sub 3/2}) + CF{sub 4} dissociation limit. In contrast to the neutral complexes, which are most stable in the face geometry, for the Rg.CF{sub 4}{sup +} ions, the calculations show that the minimum of the potential energy surface is in the vertex geometry. Experiments which have been performed only with Xe.CF{sub 4} revealed no Xe.CF{sub 4}{sup +} signal above the first ionization threshold of Xe, suggesting that the Rg.CF{sub 4}{sup +} ions are not stable above the first dissociation limit.

  4. Diagnosis and management of transthyretin familial amyloid polyneuropathy in Japan: red-flag symptom clusters and treatment algorithm.

    Science.gov (United States)

    Sekijima, Yoshiki; Ueda, Mitsuharu; Koike, Haruki; Misawa, Sonoko; Ishii, Tomonori; Ando, Yukio

    2018-01-17

    Hereditary ATTR (ATTRm) amyloidosis (also called transthyretin-type familial amyloid polyneuropathy [ATTR-FAP]) is an autosomal-dominant, adult-onset, rare systemic disorder predominantly characterized by irreversible, progressive, and persistent peripheral nerve damage. TTR gene mutations (e.g. replacement of valine with methionine at position 30 [Val30Met (p.Val50Met)]) lead to destabilization and dissociation of TTR tetramers into variant TTR monomers, which form amyloid fibrils that deposit in peripheral nerves and various organs, giving rise to peripheral and autonomic neuropathy and several non-disease specific symptoms.Phenotypic and genetic variability and non-disease-specific symptoms often delay diagnosis and lead to misdiagnosis. Red-flag symptom clusters simplify diagnosis globally. However, in Japan, types of TTR variants, age of onset, penetrance, and clinical symptoms of Val30Met are more varied than in other countries. Hence, development of a Japan-specific red-flag symptom cluster is warranted. Presence of progressive peripheral sensory-motor polyneuropathy and ≥1 red-flag sign/symptom (e.g. family history, autonomic dysfunction, cardiac involvement, carpal tunnel syndrome, gastrointestinal disturbances, unexplained weight loss, and immunotherapy resistance) suggests ATTR-FAP. Outside of Japan, pharmacotherapeutic options are first-line therapy. However, because of positive outcomes (better life expectancy and higher survival rates) with living donor transplant in Japan, liver transplantation remains first-line treatment, necessitating a Japan-specific treatment algorithm.Herein, we present a consolidated review of the ATTR-FAP Val30Met landscape in Japan and summarize findings from a medical advisory board meeting held in Tokyo on 18th August 2016, at which a Japan-specific ATTR-FAP red-flag symptom cluster and treatment algorithm was developed. Beside liver transplantation, a TTR-stabilizing agent (e.g. tafamidis) is a treatment option. Early

  5. Linearity discontinuities in Xe-filled X-ray microstrip detectors

    DEFF Research Database (Denmark)

    Zavattini, G.; Feroci, M.; Budtz-Jørgensen, Carl

    1997-01-01

    A prototype Xe + 10% CH4 microstrip detector was used to study the K-edge discontinuity in the pulse-height distribution as a function of the energy of incident X-rays. The electronics used was such that a pulse-shape rejection could be made of K-fluorescence reabsorption in the detector. The mea...

  6. Determination of adipose tissue blood flow with local 133Xe clearance. Evaluation of a new labelling technique

    DEFF Research Database (Denmark)

    Simonsen, Lene; Enevoldsen, Lotte Hahn; Bülow, Jens

    2003-01-01

    Adipose tissue blood flow was measured in six healthy, non-obese subjects with the xenon wash-out technique after labelling of the tissue by either injection of 133Xe dissolved in isotonic sodium chloride (water depot) or injection of 133Xe in gas form (gas depot). The wash-out rates were...

  7. Evaluation of cutaneous blood flow responses by 133Xe washout and a laser-Doppler flowmeter

    International Nuclear Information System (INIS)

    Engelhart, M.; Kristensen, J.K.

    1983-01-01

    A new method for noninvasive measurement of cutaneous blood flow is laser-Doppler flowmetry. The technique is based on the fact that laser light is back-scattered from the moving red blood cells, with Doppler-shifted frequencies; these impulses lead to photodetectors and are converted to flow signals. In this work we used a new system with a low noise level. Comparison was made between this technique and the atraumatic epicutaneous 133 Xe technique for measurement of cutaneous blood flow during reactive hyperemia and orthostatic pressure changes. The laser-Doppler flowmeter seems to measure blood flow in capillaries as well as in arteriovenous anastomoses, while the 133 Xe method probably measures only capillary flow. A calibration of the laser-Doppler method against the 133 Xe method would appear to be impossible in skin areas where arteriovenous anastomoses are present. The changes in blood flow during reactive hyperemia, orthostatic pressure changes, and venous stasis were found to be parallel as measured by the two methods in skin areas without shunt vessels. The laser-Doppler flowmeter would appear to be a useful supplement to the 133Xe washout method in cutaneous vascular physiology, but it is important to keep in mind that different parameters may be measured

  8. Soap films burst like flapping flags.

    Science.gov (United States)

    Lhuissier, Henri; Villermaux, Emmanuel

    2009-07-31

    When punctured, a flat soap film bursts by opening a hole driven by liquid surface tension. The hole rim does not, however, remain smooth but soon develops indentations at the tip of which ligaments form, ultimately breaking and leaving the initially connex film into a mist of disjointed drops. We report on original observations showing that these indentations result from a flaglike instability between the film and the surrounding atmosphere inducing an oscillatory motion out of its plane. Just like a flag edge flaps in the wind, the film is successively accelerated on both sides perpendicularly to its plane, inducing film thickness modulations and centrifuging liquid ligaments that finally pinch off to form the observed spray. This effect exemplifies how the dynamics of fragile objects such as thin liquid films is sensitive to their embedding medium.

  9. Single-pulse characteristics of the Xe(L) amplifier on the Xe35+ (3d→2p) transition array at λ ≅ 2.86 A

    International Nuclear Information System (INIS)

    Borisov, Alex B; Song Xiangyang; Zhang Ping; McCorkindale, John C; Khan, Shahab F; De Jonghe, Richard; Poopalasingam, Sankar; Zhao, Ji; Boyer, Keith; Rhodes, Charles K

    2006-01-01

    The triple comparison of (1) single-pulse spectral data, recorded with a CCD-equipped von Hamos spectrometer both axially and transversely; (2) axially measured time-integrated spectra registered on a film and (3) single-pulse x-ray images of the morphology of the self-trapped plasma channel, recorded simultaneously with the single-pulse spectra, establishes several leading characteristics of the saturated amplification observed on the Xe 35+ transition array at λ ≅ 2.86 A. The chief findings are (α) absolute positive correlation of amplification with the formation of a plasma channel, (β) a perfect spectral match of the amplified transitions in the comparison of axially recorded single-pulse and time-integrated film data and (γ) exact spectral correspondence of both the axially registered single-pulse and time-integrated film data with single-pulse transversely measured spectra exhibiting deep spectral hole burning at the position of the Xe 35+ array. (letter to the editor)

  10. Liquid-Xe detector for contraband detection

    Energy Technology Data Exchange (ETDEWEB)

    Vartsky, D., E-mail: david.vartsky@weizmann.ac.il [Weizmann Institute of Science, Rehovot 76100 (Israel); Israelashvili, I. [Weizmann Institute of Science, Rehovot 76100 (Israel); Nuclear Research Center of Negev (NRCN), Beer-Sheva 9001 (Israel); Cortesi, M. [National Superconducting Cyclotron Laboratory, East Lansing 48823, MI (United States); Arazi, L.; Coimbra, A.E.; Moleri, L.; Erdal, E.; Bar, D.; Rappaport, M.; Shchemelinin, S. [Weizmann Institute of Science, Rehovot 76100 (Israel); Caspi, E.N. [Nuclear Research Center of Negev (NRCN), Beer-Sheva 9001 (Israel); Aviv, O. [Soreq NRC, Yavne 81800 (Israel); Breskin, A. [Weizmann Institute of Science, Rehovot 76100 (Israel)

    2016-07-11

    We describe progress made with a liquid-Xe (LXe) detector coupled to a gaseous photomultiplier (GPM), for combined imaging and spectroscopy of fast neutrons and gamma-rays in the MeV range. The purpose of this detector is to enable the detection of hidden explosives and fissile materials in cargo and containers. The expected position resolution is about 2 m and 3.5 mm for fast neutrons and gamma-rays, respectively. Experimental results obtained using an {sup 241}Am source yielded energy and time resolutions of 11% and 1.2 ns RMS, respectively. Initial results obtained with the position-sensitive GPM are presented.

  11. Temperature enhancement of Xe(L) x-ray amplifier (λ ∼ 2.9 A) emission

    International Nuclear Information System (INIS)

    Borisov, Alex B; Zhang Ping; Racz, Ervin; McCorkindale, John C; Khan, Shahab F; Poopalasingam, Sankar; Zhao Ji; Rhodes, Charles K

    2007-01-01

    Cooling of the xenon nozzle flow to T = 230 K produces three leading effects. They are (1) a ∼2.5-fold enhancement of the Xe(L) hollow atom emission on the single-vacancy 3d → 2p charge state arrays (2) the production of amplifying self-trapped plasma channels with significantly enhanced lengths and (3) very sharply augmented emission on (2s-bar2p-bar) Xe(L) double-vacancy transitions in the λ ≅ 2.80 A region. (fast track communication)

  12. Temperature enhancement of Xe(L) x-ray amplifier ({lambda} {approx} 2.9 A) emission

    Energy Technology Data Exchange (ETDEWEB)

    Borisov, Alex B [Laboratory for X-Ray Microimaging and Bioinformatics, Department of Physics, University of Illinois at Chicago, Chicago, IL 60607-7059 (United States); Zhang Ping [Laboratory for X-Ray Microimaging and Bioinformatics, Department of Physics, University of Illinois at Chicago, Chicago, IL 60607-7059 (United States); Racz, Ervin [Laboratory for X-Ray Microimaging and Bioinformatics, Department of Physics, University of Illinois at Chicago, Chicago, IL 60607-7059 (United States); McCorkindale, John C [Laboratory for X-Ray Microimaging and Bioinformatics, Department of Physics, University of Illinois at Chicago, Chicago, IL 60607-7059 (United States); Khan, Shahab F [Laboratory for X-Ray Microimaging and Bioinformatics, Department of Physics, University of Illinois at Chicago, Chicago, IL 60607-7059 (United States); Poopalasingam, Sankar [Laboratory for X-Ray Microimaging and Bioinformatics, Department of Physics, University of Illinois at Chicago, Chicago, IL 60607-7059 (United States); Zhao Ji [Laboratory for X-Ray Microimaging and Bioinformatics, Department of Physics, University of Illinois at Chicago, Chicago, IL 60607-7059 (United States); Rhodes, Charles K [Laboratory for X-Ray Microimaging and Bioinformatics, Department of Physics, University of Illinois at Chicago, Chicago, IL 60607-7059 (United States)

    2007-11-28

    Cooling of the xenon nozzle flow to T = 230 K produces three leading effects. They are (1) a {approx}2.5-fold enhancement of the Xe(L) hollow atom emission on the single-vacancy 3d {yields} 2p charge state arrays (2) the production of amplifying self-trapped plasma channels with significantly enhanced lengths and (3) very sharply augmented emission on (2s-bar2p-bar) Xe(L) double-vacancy transitions in the {lambda} {approx_equal} 2.80 A region. (fast track communication)

  13. Actinide production in 136Xe bombardments of 249Cf

    International Nuclear Information System (INIS)

    Gregorich, K.E.

    1985-08-01

    The production cross sections for the actinide products from 136 Xe bombardments of 249 Cf at energies 1.02, 1.09, and 1.16 times the Coulomb barrier were determined. Fractions of the individual actinide elements were chemically separated from recoil catcher foils. The production cross sections of the actinide products were determined by measuring the radiations emitted from the nuclides within the chemical fractions. The chemical separation techniques used in this work are described in detail, and a description of the data analysis procedure is included. The actinide production cross section distributions from these 136 Xe + 249 Cf bombardments are compared with the production cross section distributions from other heavy ion bombardments of actinide targets, with emphasis on the comparison with the 136 Xe + 248 Cm reaction. A technique for modeling the final actinide cross section distributions has been developed and is presented. In this model, the initial (before deexcitation) cross section distribution with respect to the separation energy of a dinuclear complex and with respect to the Z of the target-like fragment is given by an empirical procedure. It is then assumed that the N/Z equilibration in the dinuclear complex occurs by the transfer of neutrons between the two participants in the dinuclear complex. The neutrons and the excitation energy are statistically distributed between the two fragments using a simple Fermi gas level density formalism. The resulting target-like fragment initial cross section distribution with respect to Z, N, and excitation energy is then allowed to deexcite by emission of neutrons in competition with fission. The result is a final cross section distribution with respect to Z and N for the actinide products. 68 refs., 33 figs., 6 tabs

  14. Structural Search for High Pressure CS2 and Xe-Cl Compounds

    Science.gov (United States)

    Zarifi, Niloofar; Tse, John S.

    2018-04-01

    The recent successful implementation of several methodologies for the prediction of crystal structures based on the first-principles electronic structure have ushered in a new area of computational chemistry. In this study, the two most popular methods, namely genetic evolution and particle swarm optimization, were applied to the investigation of stable crystalline polymorphs of solid carbon disulfide and xenon halides at high pressure. It was found that both methods have their own merits. However, there are subtleties that need to be considered for the proper execution of the methods. We found a two-dimensional (2D) layered structure that may be responsible for the superconductivity in CS2. Except for XeCl2, no thermodynamically stable crystalline Xe halides were found under 60 GPa in the halide-rich region of the phase diagram.

  15. Cryptophane-Folate Biosensor for 129Xe NMR

    Science.gov (United States)

    2014-12-01

    normal adult tissue, but as the name implies, this low affinity folate carrier is specific for the physiological form of reduced folic acid, 5- methyl ...yield. Finally, 3 was treated with 1.5 equiv of 6 and N- methyl -1,5,9-triazabicyclo[4.4.0]-decene (MTBD) in dry DMSO to give the folate recognition moiety...Cryptophane- Folate Biosensor for 129Xe NMR Najat S. Khan, Brittany A. Riggle, Garry K. Seward, Yubin Bai, and Ivan J. Dmochowski* Department of

  16. Structure and stability of solid Xe(H2)n

    International Nuclear Information System (INIS)

    Somayazulu, Maddury; Hemley, Russell J.; Dera, Przemyslaw; Smith, Jesse

    2015-01-01

    Mixtures of xenon and molecular hydrogen form a series of hexagonal, van der Waals compounds at high pressures and at 300 K. Synchrotron, x-ray, single crystal diffraction studies reveal that below 7.5 GPa, Xe(H 2 ) 8 crystallizes in a P3 - m1 structure that displays pressure-induced occupancy changes of two pairs of xenon atoms located on the 2c and 2d sites (while the third pair on yet another 2c site remains fully occupied). The occupancy becomes 1 at the P3 - m1 to R3 transition and all the xenon atoms occupy the 3d sites in the high-pressure structure. These pressure-induced changes in occupancy coincide with volume changes that maintain the average Xe:H 2 stoichiometry fixed at 1:8. The synchrotron x-ray diffraction and Raman measurements show that this unique hydrogen-bearing compound that can be synthesized at 4.2 GPa and 300 K, quenched at low temperatures to atmospheric pressure, and retained up to 90 K on subsequent warming

  17. Xe N4,5O-OOO satellite Auger spectrum

    International Nuclear Information System (INIS)

    Partanen, L; Huttula, M; Heinaesmaeki, S; Aksela, H; Aksela, S

    2007-01-01

    The N 4,5 O 1,2,3 -O 1,2,3 O 2,3 O 2,3 Auger transitions, appearing as a satellite structure in the N 4,5 -OO Auger spectrum of xenon, were studied in detail. By measuring the N 4,5 O-OOO satellite Auger spectrum both below and above the 4p ionization threshold, we were able to separate the satellite production via the direct photo-double ionization and the Auger cascade from the 4p states. The N 3 -N 4,5 O 2,3 Coster-Kronig transitions and the subsequent N 4,5 O 2,3 -O 2,3 O 2,3 O 2,3 satellite Auger transitions were calculated using the HF wavefunctions and the most intense satellite lines were assigned. The Xe N 4,5 O-OOO satellite spectrum was compared with the previously studied Kr M 4,5 N-NNN satellite Auger spectrum. The 5s orbital in Xe was found to reveal more pronounced electron correlation than the 4s orbital in Kr

  18. Reconstructing sea level from paleo and projected temperatures 200 to 2100 AD

    DEFF Research Database (Denmark)

    Grinsted, Aslak; Moore, John; Jevrejeva, Svetlana

    2010-01-01

    -proxy reconstructions assuming that the established relationship between temperature and sea level holds from 200 to 2100 ad. Over the last 2,000 years minimum sea level (-19 to -26 cm) occurred around 1730 ad, maximum sea level (12–21 cm) around 1150 AD. Sea level 2090–2099 is projected to be 0.9 to 1.3 m for the A1B...

  19. Negligible fractionation of Kr and Xe isotopes by molecular diffusion in water

    Science.gov (United States)

    Tyroller, Lina; Brennwald, Matthias S.; Busemann, Henner; Maden, Colin; Baur, Heinrich; Kipfer, Rolf

    2018-06-01

    Molecular diffusion is a key transport process for noble gases in water. Such diffusive transport is often thought to cause a mass-dependent fractionation of noble gas isotopes that is inversely proportional to the square root of the ratio of their atomic mass, referred to as the square root relation. Previous studies, challenged the commonly held assumption that the square root relation adequately describes the behaviour of noble gas isotopes diffusing through water. However, the effect of diffusion on noble gas isotopes has only been determined experimentally for He, Ne and Ar to date, whereas the extent of fractionation of Kr and Xe has not been measured. In the present study the fractionation of Kr and Xe isotopes diffusing through water immobilised by adding agar was quantified through measuring the respective isotope ratio after diffusing through the immobilised water. No fractionation of Kr and Xe isotopes was observed, even using high-precision noble gas analytics. These results complement our current understanding on isotopic fractionation of noble gases diffusing through water. Therefore this complete data set builds a robust basis to describe molecular diffusion of noble gases in water in a physical sound manner which is fundamental to assess the physical aspects of gas dynamics in aquatic systems.

  20. Generation of metallic arc spectrum of pumping discharge of XeCl laser; XeCl ekishima laser reiki hoden ni okeru arc iko to kinzoku supekutoru no hassei

    Energy Technology Data Exchange (ETDEWEB)

    Koike, H.; Yukimura, K. [Doshisha University, Kyoto (Japan)

    1997-12-20

    An arc generation of a long-pulse spiker-sustainer excimer laser with about 250ns of pulse width , is discussed by using time-varying spectroscopic method. First arcing occurs during a main discharge for laser excitation and shows XeII spectrum, while a glow-like discharge represents only XeI spectrum, the metallic spectrum such as Nil caused by vaporization of electrode material begins to appear just after the termination of the main discharge. Second arcing occurs after about 2{mu}s, which brings strong intensity of Nil spectrum. It means that the reignition arc might be produced in a metallic vapor that appears during the main discharge. Accordingly, it is concluded that the reignition arc is inherently metallic, which is different from the main arc with rare gas plasma. 9 refs., 9 figs.

  1. Radiopharmacology of inhaled [sup 133]Xe in skeletal sites containing deposits of Gaucher cells

    Energy Technology Data Exchange (ETDEWEB)

    Castronovo, F.P. Jr. (Brigham and Women' s Hospital, Boston, MA (United States) Harvard Medical School, Boston, MA (United States)); McKusick, K.A.; Doppelt, S.H. (Massachusetts General Hospital, Boston, MA (United States) Harvard Medical School, Boston, MA (United States)); Barton, N.W. (National Insts. of Health, Bethesda, MD (United States))

    1993-07-01

    Gaucher's disease is a lysomal storage disease in which cells of the reticuloendothelial system accumulate the lipid glucocerebroside. It is characterized by slowly progressive visceral and osseous involvement. One of the latter manifestations includes lipid infiltration of bone marrow. We monitored the rate of the inhaled [sup 133]Xe uptake and wash-out over diseased and normal metaphyseal and epiphyseal areas of the knee. Twenty-two patients (15 adults, 7 children) with various degrees of previously diagnosed Gaucher's disease were positioned supine under a [gamma]-camera interfaced to a computer system. All patients rebreathed [sup 133]Xe gas from a closed system for 10 min followed by 14 min of wash-out. Digitized images of the lung, liver, spleen, bony sites and soft tissue were obtained at 1 min intervals during the wash-in and wash-out phases. Counts for each ROI were normalized per 100 pixels and plotted as a function (time). Maximum uptake was also calculated by relating the counts/ROI/100 pixels to the 10 min integrated lung count during equilibrium (the administered ''dose''). There was essentially no [sup 133]Xe uptake in liver and spleen involved with Gaucher's disease. Monophasic uptake and biphasic wash-out curves were observed in the limited investigative population. Gaucher deposits released the [sup 133]Xe at a greater rate relative to soft tissue. (Author).

  2. Xe-135 and Sm-149 Isotopic Evolution Analysis Xesamo code; Analisis de la Evolucion Isotopica del Xe-135 y Sm-149. Programa Xesamo

    Energy Technology Data Exchange (ETDEWEB)

    Caro, R; Gallego, J; Martinez Fanegas, R

    1977-07-01

    In this report the time evolution analysis of the nuclides concentration Xe-135 and Sm-149 as a function of the neutron flux is carried out. The neutron flux may be any function of time. It is analyzed as well the reactivity changes associated with the xenon and samarium concentration variations. (Author) 5 refs.

  3. Strategies Used In Capture The Flag Events Contributing To Team Performance

    Science.gov (United States)

    2016-03-01

    words) Capture-the-flag (CTF) exercises are useful pedagogical tools and have been employed, both formally and informally, by academic institutions...Much like their physical counterparts, cyber CTF exercises hold pedagogical value and are gaining wide popularity. Existing studies on CTF exercises...examined either how they benefit learning, or are best conducted. To our knowledge, no formal study has yet looked at the relationship between the

  4. Upper bound theorem for odd-dimensional flag triangulations of manifolds

    Czech Academy of Sciences Publication Activity Database

    Adamaszek, M.; Hladký, Jan

    2016-01-01

    Roč. 62, č. 3 (2016), s. 909-928 ISSN 0025-5793 EU Projects: European Commission(XE) 628974 - PAECIDM Institutional support: RVO:67985840 Keywords : f-vector * manifold * extremal graph theory Subject RIV: BA - General Mathematics Impact factor: 0.667, year: 2016 http:// journals .cambridge.org/action/displayAbstract?fromPage=online&aid=10346369&fulltextType=RA&fileId=S0025579316000115

  5. High diagnostic accuracy of the Sysmex XT-2000iV delta total nucleated cells on effusions for feline infectious peritonitis.

    Science.gov (United States)

    Giordano, Alessia; Stranieri, Angelica; Rossi, Gabriele; Paltrinieri, Saverio

    2015-06-01

    The ΔWBC (the ratio between DIFF and BASO counts of the Sysmex XT-2000iV), hereafter defined as ΔTNC (total nucleated cells), is high in effusions due to feline infectious peritonitis (FIP), as cells are entrapped in fibrin clots formed in the BASO reagent. Similar clots form in the Rivalta's test, a method with high diagnostic accuracy for FIP. The objective of this study was to determine the diagnostic accuracy for FIP and the optimal cutoff of ΔTNC. After a retrospective search of our database, DIFF and BASO counts, and the ΔTNC from cats with and without FIP were compared to each other. Sensitivity, specificity, and positive and negative likelihood ratios (LR+, LR-) were calculated. A ROC curve was designed to determine the cutoff for best sensitivity and specificity. Effusions from 20 FIP and 31 non-FIP cats were analyzed. The ΔTNC was higher (P  2.5 had 100% specificity. The ΔTNC has a high diagnostic accuracy for FIP-related effusions by providing an estimate of precipitable proteins, as the Rivalta's test, in addition to the cell count. As fibrin clots result in false lower BASO counts, the ΔTNC is preferable to the WBC count generated by the BASO channel alone in suspected FIP effusions. © 2015 American Society for Veterinary Clinical Pathology.

  6. Study of temperature and radiation induced microstructural changes in Xe-implanted UO2 by TEM, STEM, SIMS and positron spectroscopy

    International Nuclear Information System (INIS)

    Djourelov, Nikolay; Marchand, Benoît; Marinov, Hristo; Moncoffre, Nathalie; Pipon, Yves; Bérerd, Nicolas; Nédélec, Patrick; Raimbault, Louis; Epicier, Thierry

    2013-01-01

    Doppler broadening of annihilation gamma-line combined with a slow positron beam (SPB) was used to measure the momentum density distribution of annihilating pairs in a set of sintered UO 2 samples implantated with 800-keV 136 Xe 2+ at fluences of 1 × 10 15 and 1 × 10 16 Xe cm −2 . The effect of prolonged post-implantation annealing at 1673 and 1873 K, grain size, and 152-MeV Iodine irradiation were studied by analysis of S(E) profiles and S-W maps and discussed versus secondary ion mass spectroscopy (SIMS), scanning transmission electron microscopy results. Spectroscopy with SPB and SIMS is an excellent combination of complementary techniques for studying the formation and evolution of Xe-bubbles, and Xe retention

  7. Collective states of even Xe isotopes in IBM+MQRPA

    Directory of Open Access Journals (Sweden)

    Efimov A. D.

    2016-01-01

    Full Text Available A modification of the Quasiparticle Random Phase Approximation (QRPA with small ground state correlations is suggested. The lowest energy phonon is used as the image of d-boson of the Interacting Boson Model 1 (IBM1 and applied to microscopical calculations of the IBM1 parameters. Results are compared with experimental data for Xe isotopes.

  8. Boltzmann equation analysis of electrons swarm parameters and properties of excited particle number densities in Xe/Ne plasmas. Laser absorption effect; Xe/Ne plasma chudenshi yuso keisu narabi ni reiki ryushisu mitsudo tokusei no Boltzmann hoteishiki kaiseki. Laser ko kyushu koka

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, S.; Sugawara, H.; Ventzek, P.; Sakai, Y. [Hokkaido University, Sapporo (Japan)

    1998-06-01

    Xe/Ne plasmas are important for plasma display panels and VUV light sources. However, reactions between electrons and excited particles in the mixtures are so complicated that influence of the reactions on the plasma properties is not understood well. In this work, taking account of reactions through which electrons are produced, such as cumulative and Penning ionization, and of transition between excited levels, the electron and excited particle properties in Xe/Ne plasmas are calculated using the Boltzmann equation. The ionization coefficient and electron drift velocity agreed with experimental data. The influence of laser absorption in Xe/Ne plasmas on the plasma properties is also discussed. 25 refs., 15 figs.

  9. Infrared Spectra of Novel NgBeSO2 Complexes (Ng = Ne, Ar, Kr, Xe) in Low Temperature Matrixes.

    Science.gov (United States)

    Yu, Wenjie; Liu, Xing; Xu, Bing; Xing, Xiaopeng; Wang, Xuefeng

    2016-11-03

    The novel noble-gas complexes NgBeSO 2 (Ng = Ne, Ar, Kr, Xe) have been prepared in the laser-evaporated beryllium atom reactions with SO 2 in low-temperature matrixes. Doped with heavier noble gas, the guest (Ar, Kr, Xe) atom can substitute neon to form more stable complex. Infrared spectroscopy and theoretical calculations are used to confirm the band assignment. The dissociation energies are calculated at 0.9, 4.0, 4.7, and 6.0 kcal/mol for NeBeSO 2 , ArBeSO 2 , KrBeSO 2 , and XeBeSO 2 , respectively, at the CCSD(T) level. Quantum chemical calculations demonstrate that the Ng-Be bonds in NgBeSO 2 could be formed by the combination of electron-donation and ion-induced dipole interactions. The Wiberg bond index (WBI) values of Ng-Be bonds and LOL (localized orbital locator) profile indicate that the Ng-Be bond exhibits a gradual increase in covalent character along Ne to Xe.

  10. Carbon budget of Ontario's managed forests and harvested wood products, 2001–2100

    Science.gov (United States)

    Jiaxin Chen; Stephen J. Colombo; Michael T. Ter-Mikaelian; Linda S. Heath

    2010-01-01

    Forest and harvested wood products (HWP) carbon (C) stocks between 2001 and 2100 for Ontario's managed forests were projected using FORCARB-ON, an adaptation of the U.S. national forest C budget model known as FORCARB2. A fire disturbance module was introduced to FORCARB-ON to simulate the effects of wildfire on C, and some of the model's C pools were re-...

  11. XeF pump laser. Final technical report

    International Nuclear Information System (INIS)

    1980-03-01

    The goal of this program was to demonstrate operation of an XeF laser of adequate energy, efficiency and beam quality at high repetition rates. The specific design goals were: PRF greater than or equal to 10 kHz, energy output greater than or equal to 50 mJ/pulse, efficiency greater than or equal to 0.3%, and beam divergence angle less than or equal to 20x diffraction limited. In the following sections of this report we will discuss how these goals have been met

  12. Developing an early alert system for metastatic spinal cord compression (MSCC): Red Flag credit cards.

    Science.gov (United States)

    Turnpenney, Jackie; Greenhalgh, Sue; Richards, Lena; Crabtree, Annamaria; Selfe, James

    2015-01-01

    To produce a user-friendly list of metastatic spinal cord compression (MSCC) Red Flags for non-specialist 'generalist' front-line clinicians working in primary-care settings. The issue of identifying MSCC early to prevent serious long-term disability was a key theme identified by the Task and Finish Group at Greater Manchester and Cheshire Cancer Network (GMCCN) in 2009. It was this group who initially brokered and then coordinated the current development as part of their strategic approach to improving care for MSCC patients. A consensus-building approach that considered the essential minimum data requirements to raise the index of suspicion suggestive of MSCC was adopted. This followed a model of cross-boundary working to facilitate the mutual sharing of expertise across a variety of relevant clinical specialisms. A guideline aimed at helping clinicians to identify the early signs and symptoms of MSCC was produced in the form of a credit card. This credit card includes key statements about MSCC, signposting to key sources of additional information and a user-friendly list of Red Flags which has been developed into an eight-item Red Flag mnemonic. To date, an excess of 120,000 cards have been printed by a variety of organisations and the distribution of the cards is ongoing across the United Kingdom and the Republic of Ireland.

  13. Platelet turnover in stable coronary artery disease - influence of thrombopoietin and low-grade inflammation.

    Directory of Open Access Journals (Sweden)

    Sanne Bøjet Larsen

    Full Text Available BACKGROUND: Newly formed platelets are associated with increased aggregation and adverse outcomes in patients with coronary artery disease (CAD. The mechanisms involved in the regulation of platelet turnover in patients with CAD are largely unknown. AIM: To investigate associations between platelet turnover parameters, thrombopoietin and markers of low-grade inflammation in patients with stable CAD. Furthermore, to explore the relationship between platelet turnover parameters and type 2 diabetes, prior myocardial infarction, smoking, age, gender and renal insufficiency. METHODS: We studied 581 stable CAD patients. Platelet turnover parameters (immature platelet fraction, immature platelet count, mean platelet volume, platelet distribution width and platelet large cell-ratio were determined using automated flow cytometry (Sysmex XE-2100. Furthermore, we measured thrombopoietin and evaluated low-grade inflammation by measurement of high-sensitive CRP and interleukin-6. RESULTS: We found strong associations between the immature platelet fraction, immature platelet count, mean platelet volume, platelet distribution width and platelet large cell ratio (r = 0.61-0.99, p<0.0001. Thrombopoietin levels were inversely related to all of the platelet turnover parameters (r = -0.17--0.25, p<0.0001. Moreover, thrombopoietin levels were significantly increased in patients with diabetes (p = 0.03 and in smokers (p = 0.003. Low-grade inflammation evaluated by high-sensitive CRP correlated significantly, yet weakly, with immature platelet count (r = 0.10, p = 0.03 and thrombopoietin (r = 0.16, p<0.001. Also interleukin-6 correlated with thrombopoietin (r = 0.10, p = 0.02. CONCLUSION: In stable CAD patients, thrombopoietin was inversely associated with platelet turnover parameters. Furthermore, thrombopoietin levels were increased in patients with diabetes and in smokers. However, low-grade inflammation did not seem to have a

  14. Superstring field theories on super-flag manifolds: superdiff S1/S1 and superdiff S1/super S1

    International Nuclear Information System (INIS)

    Zhao Zhiyong; Wu, Ke; Saito, Takesi

    1987-01-01

    We generalize the geometric approach of Bowick and Rajeev [BR] to superstring field theories. The anomaly is identified with nonvanishing of the Ricci curvature of the super-flag manifold. We explicitly calculate the curvatures of superdiff S 1 /S 1 and superdiff S 1 /superS 1 using super-Toeplitz operator techniques. No regularization is needed in this formalism. The critical dimension D=10 is rediscovered as a result of vanishing curvature of the product bundle over the super-flag manifold. (orig.)

  15. Rearrangement of valence neutrons in the neutrinoless double-β decay of 136Xe

    Science.gov (United States)

    Szwec, S. V.; Kay, B. P.; Cocolios, T. E.; Entwisle, J. P.; Freeman, S. J.; Gaffney, L. P.; Guimarães, V.; Hammache, F.; McKee, P. P.; Parr, E.; Portail, C.; Schiffer, J. P.; de Séréville, N.; Sharp, D. K.; Smith, J. F.; Stefan, I.

    2016-11-01

    A quantitative description of the change in ground-state neutron occupancies between 136Xe and 136Ba, the initial and final state in the neutrinoless double-β decay of 136Xe, has been extracted from precision measurements of the cross sections of single-neutron-adding and -removing reactions. Comparisons are made to recent theoretical calculations of the same properties using various nuclear-structure models. These are the same calculations used to determine the magnitude of the nuclear matrix elements for the process, which at present disagree with each other by factors of 2 or 3. The experimental neutron occupancies show some disagreement with the theoretical calculations.

  16. 38 CFR 1.9 - Description, use, and display of VA seal and flag.

    Science.gov (United States)

    2010-07-01

    ... stars represent the five branches of military service. The crossed flags represent our nation's history... employees. (D) Official VA signs. (E) Official publications or graphics issued by and attributed to VA, or...) Souvenir or novelty items. (iii) Toys or commercial gifts or premiums. (iv) Letterhead design, except on...

  17. Measurement of the Auger decay after resonance excitation of Xe 4d and Kr 3d resonance lines

    International Nuclear Information System (INIS)

    Eberhardt, W.; Kalkoffen, G.; Kunz, C.

    1978-03-01

    The Nsub(4,5) 0sub(2,3) 0sub(2,3) Auger spectra from Xe and the Msub(4,5) Nsub(2,3) Nsub(2,3) Auger spectra from Kr are investigated for different photon energies around threshold of ionization. When exciting at the resonance line (4d 9 5s 2 5p 6 6p for Xe and 3d 9 4s 2 4p 6 5p for Kr) we observe the usual Auger multiplet structure to be shifted to higher kinetic energies. Additionally, new lines appear which can be assigned to shake-up processes int he Xe + and Kr + ions. (orig.) [de

  18. Synchrotron x-ray-diffraction study of the structure and growth of Xe films adsorbed on the Ag(111) surface

    International Nuclear Information System (INIS)

    Dai, P.; Wu, Z.; Angot, T.; Wang, S.; Taub, H.; Ehrlich, S.N.

    1999-01-01

    Synchrotron x-ray scattering has been used to investigate the structure and growth of perhaps the simplest of all films: xenon physisorbed on the Ag(111) surface. High-resolution x-ray scans of the in-plane structure and lower-resolution scans (specular and nonspecular) of the out-of-plane order were performed. The Xe films were prepared under both quasiequilibrium and kinetic growth conditions, and have fewer structural defects than those investigated previously by others on graphite substrates. Under quasiequilibrium conditions, the bulk Xe-Xe spacing is reached at monolayer completion, and the monolayer and bilayer lattice constants at coexistence are inferred equal to within 0.005 Angstrom, consistent with theoretical calculations. The Xe/vacuum interface profile for a complete monolayer and bilayer grown at quasiequilibrium is found to be sharper than for kinetically grown films. At coverages above two layers, diffraction scans along the Xe(01l) rod for quasiequilibrated films are consistent with the presence of two domains having predominantly an ABC stacking sequence and rotated 60 degree with respect to each other about the surface normal. Annealing of these films alters neither the population of the two domains nor the fraction of ABA stacking faults. The thickest film grown under quasiequilibrium conditions exceeds 220 Angstrom (resolution limited). Under kinetic growth conditions, x-ray intensity oscillations at the Xe anti-Bragg position of the specular rod are observed as a function of time, indicating nearly layer-by-layer growth. Up to four complete oscillations corresponding to a film of eight layers have been observed before the intensity is damped out; the number of oscillations is found to depend on the substrate temperature, the growth rate, and the quality of the Ag(111) substrate. The specular reflectivity from kinetically grown films at nominal coverages of three and four layers has been analyzed using a Gaussian model which gives a film

  19. Ventilation abnormalities in obstructive airways disorder. Detection with pulmonary dynamic densitometry by means of spinal CT versus dynamic Xe-133 SPECT

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi; Nishigauchi, Kazuya; Kume, Norihiko; Takana, Katsuyuki; Koike, Shinji; Shimizu, Kensaku; Matsunaga, Naofumi

    1999-01-01

    The usefulness of pulmonary dynamic densitometry (PDD) acquired by spiral computed tomography (CT) to detect ventilation abnormalities in obstructive airway disorders was evaluated in comparison with dynamic xenon-133 (Xe-133) SPECT. Eight-second, continuous spiral CT scan was performed over 2-3 respiratory cycles in six healthy volunteers, 19 patients with airways disorder, and six patients with restrictive lung disease. The data set were reconstructed as 36 one-second temporally overlapping images at 0.2-second intervals, and regional PDD curves were displayed. Regional ventilation was assessed by Xe-133 clearance-time on Xe-133 SPECT. Normal lungs showed smooth, sinusoidal PDD curves with maximal amplitude in lung attenuation change (MALAC) of 54.9+24.5 HU; whereas, obstructive airways disorders with prolonged Xe-133 clearance showed significantly diminished MALAC (31.6+20.1 HU, P<0.0001), accompanied by irregularity, asynchronous phase, and deterioration of normal ventral-to-dorsal gradients in MALAC and lung attenuation. Restrictive diseases without prolonged Xe-133 clearance did not show statistically significant reduction in MALAC. In total 251 lung regions, regional MALAC correlated inversely with Xe-133 clearance-time (r=842). PDD acquired by spiral CT is acceptable for detecting ventilation abnormalities in obstructive airways disorder. (author)

  20. I-Xe and 40Ar-39Ar analyses of silicate from the Eagle Station pallasite and the anomalous iron meteorite Enon

    International Nuclear Information System (INIS)

    Niemeyer, S.

    1983-01-01

    Silicate from two unusual iron-rich meteorites were analyzed by the I-Xe and 40 Ar- 39 Ar techniques. Enon, an anomalous iron meteorite with chondritic silicate, shows no loss of radiogenic 40 Ar at low temperature, and gives a plateau age of 4.59 +- 0.03 Ga. Although the Xe data fail to define an I-Xe correlation the inferred Pu/U ratio is more than 2 σ above the chondritic value, and the Pu abundance derived from the concentration of Pu-fission Xe is 6 times greater than the abundance inferred for CI meteorites. These findings for Enon, coupled with data for IAB iron meteorites, suggest that presence of chondritic silicate in an iron-rich meteorite is diagnostic of an old radiometric age with little subsequent thermal disturbance. The Eagle Station pallasite, the most 16 O-rich meteorite known, gives a complex 40 Ar- 39 Ar age pattern which suggests a recent severe thermal disturbance. The absence of excess 129 Xe, and the low trapped Ar and Xe contents, are consistent with this interpretation. The similarity between 40 Ar- 39 Ar data for Eagle Station and for the olivine-rich meteorite Chassigny lends credence to the previous suggestion of a connection between Chassigny and pallasites. (author)

  1. A new search for the atomic EDM of {sup 129}Xe at FRM-II

    Energy Technology Data Exchange (ETDEWEB)

    Kuchler, F., E-mail: florian.kuchler@tum.de [Excellence Cluster Universe and Technische Universität München (Germany); Babcock, E. [Juelich Center for Neutron Science (Germany); Burghoff, M. [Physikalisch-Technische Bundesanstalt (Germany); Chupp, T.; Degenkolb, S. [University of Michigan (United States); Fan, I. [Physikalisch-Technische Bundesanstalt (Germany); Fierlinger, P. [Excellence Cluster Universe and Technische Universität München (Germany); Gong, F. [University of Michigan (United States); Kraegeloh, E. [Excellence Cluster Universe and Technische Universität München (Germany); Kilian, W.; Knappe-Grüneberg, S. [Physikalisch-Technische Bundesanstalt (Germany); Lins, T.; Marino, M.; Meinel, J.; Niessen, B. [Excellence Cluster Universe and Technische Universität München (Germany); Sachdeva, N. [University of Michigan (United States); Salhi, Z. [Juelich Center for Neutron Science (Germany); Schnabel, A.; Seifert, F. [Physikalisch-Technische Bundesanstalt (Germany); Singh, J. [Michigan State University and NSCL (United States); and others

    2016-12-15

    Permanent electric dipole moments (EDMs) arise due to the breaking of time-reversal or, equivalently, CP-symmetry. Although EDM searches have so far only set upper limits, which are many orders of magnitude larger than Standard Model (SM) predictions, the motivation for more sensitive searches is stronger than ever. A new effort at FRM-II incorporating {sup 129}Xe and {sup 3}He as a co-magnetometer can potentially improve the current limit. The noble gas mixture of {sup 129}Xe and {sup 3}He is simultanously polarized by spin-exchange optical pumping and then transferred into a high-performance magnetically shielded room. Inside, both species can freely precess in the presence of applied magnetic and electric fields. The precession signals are detected by LTc SQUID sensors. In EDM cells with silicon electrodes we observed spin lifetimes in excess of 2500 s without and with high-voltage applied. This meets one requirement to achieve our goal of improving the EDM limit on {sup 129}Xe by several orders of magnitude.

  2. 'Clickable' hydrosoluble PEGylated cryptophane as a universal platform for 129Xe magnetic resonance imaging biosensors

    International Nuclear Information System (INIS)

    Delacour, Lea; Kotera, Naoko; Traore, Tenin; Garcia-Argote, Sebastien; Puente, Celine; Gravel, Edmond; Rousseau, Bernard; Leteurtre, Francois; Boulard, Yves; Tassali, Nawal; Boutin, Celine; Leonce, Estelle; Berthault, Patrick

    2013-01-01

    We describe the synthesis of a highly water-soluble cryptophane 1 that can be seen as a universal platform for the construction of 129 Xe magnetic resonance imaging (MRI)-based biosensors. Compound 1 is easily functionalized by Huisgen cycloaddition and exhibits excellent xenon-encapsulation properties. In addition, 1 is nontoxic at the concentrations typically used for hyper-polarized 129 Xe MRI. (authors)

  3. Intensification of Climate-Carbon Feedbacks after 2100 and Implications for Disturbance Regimes

    Science.gov (United States)

    Randerson, J. T.; Lindsay, K. T.; Munoz, E.; Fu, W.; Hoffman, F. M.; Moore, J. K.; Doney, S. C.; Mahowald, N. M.; Bonan, G. B.

    2014-12-01

    Long-term ecosystem and carbon cycle responses to climate change are needed to inform mitigation policy, yet our understanding of how these responses may evolve after 2100 remains highly uncertain. Using the Community Earth System Model (version 1.0), we quantified climate-carbon feedbacks from 1850 to 2300 for the Representative Concentration Pathway 8.5 (and its extension). In three simulations, land and ocean biogeochemical models were exposed to the same trajectory of increasing atmospheric CO2. In one simulation, atmospheric CO2 and other forcing agents were radiatively active (fully coupled), modifying temperature and other aspects of climate. In another, CO2 was radiatively uncoupled, and in the third, both CO2 and other atmospheric forcing agents (including CH4, N2O, and aerosols) were radiatively uncoupled. In the fully coupled simulation, global mean air temperatures increased by 9.3°C from 1850 to 2300, with 4.4°C of this warming occurring after 2100. Without radiative forcing from CO2, cumulative warming was much lower at 2.4°C, but exceeding 2°C targets needed to avoid dangerous interference with the climate system. In response to climate change, ocean and land rates of carbon uptake were reduced, with the size of the impact increasing over time. In the oceans, reductions in cumulative carbon uptake from climate change increased from 3% during the 20th century to 40% during the 23rd century. By 2300, climate change had reduced cumulative ocean uptake by 330 Pg C, from 1410 Pg C to 1080 Pg C. Most of this reduction occurred after 2100 as a consequence of increases in surface stratification and decreases in Atlantic meridional overturning circulation. Land fluxes similarly diverged over time, with climate change inducing a cumulative loss of 230 Pg C by 2300. On land the intensification of the hydrological cycle globally increased terrestrial water storage, although asymmetric responses were observed across different continents in the tropics. Net

  4. Reproducibility of estimation of blood flow in the human masseter muscle from measurements of 133Xe clearance

    International Nuclear Information System (INIS)

    Monteiro, A.A.; Kopp, S.

    1989-01-01

    The reproducibility of estimations of the masseter intramuscular blood flow (IMBF) was assessed bilaterally within and between clinical sessions. The 133 Xe clearance in nine normal individuals was measured before, during, and immediately after endurance of isometric contraction at an attempted level of 50% of maximum voluntary clenching contraction. An overall low reproducibility of the estimations was found. This result was probably caused by uncertainties about the excact site of intramuscular 133 Xe deposition, errors in assessment of the plots of clearance, and variabilities in the relative contraction levels sustained, especially in the overall muscle effort. In agreement with previous reports concerning other skeletal muscles, the 133 Xe clearance method provided inconsistent estimates of absolute values of IMBF also in this clinical setting. Although there was a high intra-individual variation in the relative level of isometric contraction sustained, the endurance test induced distinct changes in IMBF, among which the estimate of post-endurance hyperemia was the most consistent for each individual. Therefore, measurements of 133 Xe clearance seem to be useful to detect intra-induvidual changes in masseter IMBF resulting from isometric work. 21 refs

  5. Search for electric dipole moment in 129Xe atom using active nuclear spin maser

    Directory of Open Access Journals (Sweden)

    Ichikawa Y.

    2014-03-01

    Full Text Available An experimental search for an electric dipole moment in the diamagnetic atom 129Xe is in progress through the precision measurement of spin precession frequency using an active nuclear spin maser. A 3He comagnetometer has been incorporated into the active spin maser system in order to cancel out the long-term drifts in the external magnetic field. Also, a double-cell geometry has been adopted in order to suppress the frequency shifts due to interaction with polarized Rb atoms. The first EDM measurement with the 129Xe active spin maser and the 3He comagnetometer has been conducted.

  6. Influence of Selected Parameters of XeCl Excimer Laser System on Characteristics of Radiation Pulses

    International Nuclear Information System (INIS)

    Pokora, L.; Iwanejko, L.

    1998-01-01

    We present the dependences of energy and duration of radiation pulses as well as efficiency of XeCl laser on selected parameters of the laser system such as: C 2 capacitance, the separating inductance, L S , the distance between electrodes in laser's chamber, d K and also the supply voltage, U 0 , composition, and pressure of the active-medium mixture of gases. Results of numerical computations relate to a three-component mixture of gases, He-Xe-HCl, of the active medium of the excimer laser. (author)

  7. Adsorption properties of fission gases Xe and Kr on pristine and doped graphene: A first principle DFT study

    Energy Technology Data Exchange (ETDEWEB)

    Vazhappilly, Tijo, E-mail: tijoj@barc.gov.in [Theoretical Chemistry Section, Chemistry Group, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Ghanty, Tapan K., E-mail: tapang@barc.gov.in [Theoretical Chemistry Section, Chemistry Group, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Homi Bhabha National Institute, Training School Complex, Anushakti Nagar, Mumbai 400094 (India); Jagatap, B.N. [Theoretical Chemistry Section, Chemistry Group, Bhabha Atomic Research Centre, Mumbai 400 085 (India)

    2017-07-15

    Graphene has excellent adsorption properties due to large surface area and has been used in applications related to gas sorption and separation. The separation of radioactive noble gases using graphene is an interesting area of research relevant to nuclear waste management. Radioactive noble gases Xe and Kr are present in the off-gas streams from nuclear fission reactors and spent nuclear fuel reprocessing plants. The entrapment of these volatile fission gases is important in the context of nuclear safety. The separation of Xe from Kr is extremely difficult, and energy intensive cryogenic distillation is generally employed. Physisorption based separation techniques using porous materials is a cost effective alternative to expensive cryogenic distillation. Thus, adsorption of noble gases on graphene is relevant for fundamental understanding of physisorption process. The properties of graphene can be tuned by doping and incorporation of defects. In this regard, we study the binding affinity of Xe and Kr in pristine and doped graphene sheets. We employ first principle calculations using density functional theory, corrected for dispersion interactions. The structural parameters obtained from the current study show excellent agreement with the available theoretical and experimental observations on similar systems. Noble gas adsorption energies on pristine graphene match very well with the available literature. Our results show that the binding energy of fission gases Xe and Kr on graphene can be considerably improved through doping the lattice with a heteroatom. - Graphical abstract: The adsorption of radioactive fission gases Xe and Kr on pristine/doped graphene is an interesting topic in the context of nuclear waste management. Previous experimental and computational studies about Xe/Kr adsorption on graphene were limited to only on pristine graphene. The doping by hetero atom changes the electronic properties of graphene and creates active sites in the lattice. Based

  8. The readmission risk flag: using the electronic health record to automatically identify patients at risk for 30-day readmission.

    Science.gov (United States)

    Baillie, Charles A; VanZandbergen, Christine; Tait, Gordon; Hanish, Asaf; Leas, Brian; French, Benjamin; Hanson, C William; Behta, Maryam; Umscheid, Craig A

    2013-12-01

    Identification of patients at high risk for readmission is a crucial step toward improving care and reducing readmissions. The adoption of electronic health records (EHR) may prove important to strategies designed to risk stratify patients and introduce targeted interventions. To develop and implement an automated prediction model integrated into our health system's EHR that identifies on admission patients at high risk for readmission within 30 days of discharge. Retrospective and prospective cohort. Healthcare system consisting of 3 hospitals. All adult patients admitted from August 2009 to September 2012. An automated readmission risk flag integrated into the EHR. Thirty-day all-cause and 7-day unplanned healthcare system readmissions. Using retrospective data, a single risk factor, ≥ 2 inpatient admissions in the past 12 months, was found to have the best balance of sensitivity (40%), positive predictive value (31%), and proportion of patients flagged (18%), with a C statistic of 0.62. Sensitivity (39%), positive predictive value (30%), proportion of patients flagged (18%), and C statistic (0.61) during the 12-month period after implementation of the risk flag were similar. There was no evidence for an effect of the intervention on 30-day all-cause and 7-day unplanned readmission rates in the 12-month period after implementation. An automated prediction model was effectively integrated into an existing EHR and identified patients on admission who were at risk for readmission within 30 days of discharge. © 2013 Society of Hospital Medicine.

  9. Multicurie, transportable, integrally shielded 123Xe → 123I generator and processing system for high-purity iodine-123 production

    International Nuclear Information System (INIS)

    Lagunas-Solar, M.C.; Thibeau, H.L.; Goodart, C.E.; Little, F.E.; Navarro, N.J.; Hartnett, D.E.

    1985-01-01

    An integrally shielded 123 Xe → 123 I generator system has been designed and tested under production conditions for its suitability as a multicurie handling device from which to produce radiopharmaceutical-quality high-purity no-carrier-added (NCA) 123 I. The 123 Xe → 123 I generator system is expected to provide an alternative to current techniques and to increase the availability and reliability of high-purity 123 I made via the 127 I(p,5n) 123 Xe → 123 I nuclear reaction. The generator system is based on the Crocker Nuclear Laboratory's continuous-flow production system which has been operating since 1974 for the multicurie production of 123 I. The generator system, which consists of an integrally shielded xenon trap and separate loading and processing apparatuses, is simple and reliable to operate, can be adapted to computerized control, and provides a safe working environment for the repeated handling of multicurie amounts of Xe-I radioactivities

  10. Isotope Shifts and Hyperfine Structure in the[Xe]4f(7)5d 6s(2) D-2(J)->[Xe]4f(7)5d 6s 6p F-9(J+1) Transitions of Gadolinium

    International Nuclear Information System (INIS)

    Blaum, K.; Bushaw, Bruce A.; Diel, S; Geppert, Ch; Kuschnick, A; Muller, P.; Nortershauser, W.; Schmitt, A.; Wendt, K.

    1999-01-01

    High-resolution resonance ionization mass spectrometry has been used to measure isotope shifts and hyperfine structure in all[Xe] 4f 7 5d 6s2 9DJ ---[Xe] 4f 7 5d 6s 6p 9FJ+1 (J= 2-6) and the[Xe] 4f 7 5d 6s2 9D6---[Xe] 4f 7 5d 6s 6p 9D5 transitions of gadolinium (Gd I). Gadolinium atoms in an atomic beam were excited with a tunable single-frequency laser in the wavelength range of 422 - 429 nm. Resonant excitation was followed by photoionization with the 363.8 nm line of an argon ion laser and resulting ions were mass separated and detected with a quadrupole mass spectrometer. Isotope shifts for all stable gadolinium isotopes in these transitions have been measured for the first time. Additionally, the hyperfine structure constants of the upper states have been derived for the isotopes 155, 157Gd and are compared with previous work. Using prior experimental values for the mean nuclear charge radii, derived from the combination of muonic atoms and electron scattering data, field shift a nd specific mass shift coefficients for the investigated transitions have been determined and nuclear charge parameters l for the minor isotopes 152, 154Gd have been calculated

  11. Nondipole effects in the photoionization of Xe 4d: Evidence for quadrupole satellites

    International Nuclear Information System (INIS)

    Hemmers, O.; Guillemin, R.; Wolska, A.; Lindle, D.W.; Rolles, D.; Cheng, K.T.; Johnson, W.R.; Zhou, H.L.; Manson, S.T.

    2004-01-01

    Full text: We measured the nondipole parameters for the spin-orbit depletes Xe 4d 5/2 and Xe 4d 3/2 over a photonenergy range from 100 eV to 250 eV at beamline 8.0.1.3 of the Advanced Light Source at the Lawrence Berkeley National Laboratory. Significant nondipole effects are found at relatively low energies as a result of Cooper minima in dipole channels and interchannel coupling in quadrupole channels. Most importantly, sharp disagreement between experiment and theory, when otherwise excellent agreement was expected, has provided the first evidence of satellite two-electron quadrupole photoionization transitions, along with their crucial importance for a quantitatively accurate theory

  12. Independent Yields of Kr and Xe Fragments at Photofission of Odd Nuclei ^{237}Np and ^{243}Am

    CERN Document Server

    Gangrsky, Yu P; Myshinskii, G V; Penionzhkevich, Yu E

    2004-01-01

    he independent yields of fragments Kr (A=89-93) and Xe (A=135-142) at photofission of odd nuclei 237Np and 243Am are presented. The experiments were performed using the bremsstrahlung of 25 MeV electrons on the microtron of FLNR, JINR. A technique was used that included the transportation of fragments which escaped from the target with the gas flow through a capillary and the condensation of inert gases in a cryostat at the temperature of liquid nitrogen. Kr and Xe isotopes were identified by the spectra of their daughter products. The mass number distributions of the independent yields of Kr and Xe isotopes and of the complementary fragments (Y and La at the photofission of ^{237}Np and Nb and Pr at the photofission of ^{243}Am) were obtained.

  13. Deep-inelastic scattering in 124,136Xe+58,64Ni at energies near the Coulomb barrier

    International Nuclear Information System (INIS)

    Gehring, J.; Back, B.B.; Chan, K.C.; Freer, M.; Henderson, D.; Jiang, C.L.; Rehm, K.E.; Schiffer, J.P.; Wolanski, M.; Wuosmaa, A.H.; Gehring, J.; Wolanski, M.

    1997-01-01

    Cross sections, angular distributions, and mass distributions have been measured for deep-inelastic scattering in 124 Xe+ 58 Ni and 136 Xe+ 64 Ni at laboratory energies in the vicinity of the Coulomb barrier. The mass distributions show distinct components due to deep-inelastic and fissionlike processes. The strength of deep-inelastic scattering is similar in the two systems measured and comparable to previous measurements in 58 Ni+ 112,124 Sn. copyright 1997 The American Physical Society

  14. Confinement and correlation effects in the Xe-C{sub 60} generalized oscillator strengths

    Energy Technology Data Exchange (ETDEWEB)

    Amusia, M. Ya. [Racah Institute of Physics, Hebrew University, 91904 Jerusalem (Israel); A. F. Ioffe Physical-Technical Institute, 194021 St. Petersburg (Russian Federation); Chernysheva, L. V. [A. F. Ioffe Physical-Technical Institute, 194021 St. Petersburg (Russian Federation); Dolmatov, V. K. [Department of Physics and Earth Science, University of North Alabama, Florence, Alabama 35632 (United States)

    2011-12-15

    The impact of both confinement and electron correlation on generalized oscillator strengths (GOS's) of endohedral atoms, A-C{sub 60}, is theoretically studied choosing the Xe-C{sub 60} 4d, 5s, and 5p fast electron impact ionization as the case study. Calculations are performed in the transferred to the atom energy region beyond the 4d threshold, {omega}=75-175 eV. The calculation methodology combines the plane-wave Born approximation, Hartree-Fock approximation, and random-phase approximation with exchange in the presence of the C{sub 60} confinement. The confinement is modeled by a spherical {delta}-function-like potential as well as by a square well potential to evaluate the effect of the finite thickness of the C{sub 60} cage on the Xe-C{sub 60} GOS's. Dramatic distortion of the 4d, 5p, and 5s GOS's by the confinement is demonstrated, compared to the free atom. Considerable contributions of multipolar transitions beyond dipole transitions in the calculated GOS's are revealed, in some instances. The vitality of accounting for electron correlation in calculation of the Xe-C{sub 60} 5s and 5p GOS's is shown.

  15. Xerostomia Quality of Life Scale (XeQoLS) questionnaire: validation of Italian version in head and neck cancer patients.

    Science.gov (United States)

    Lastrucci, Luciana; Bertocci, Silvia; Bini, Vittorio; Borghesi, Simona; De Majo, Roberta; Rampini, Andrea; Gennari, Pietro Giovanni; Pernici, Paola

    2018-01-01

    To translate the Xerostomia Quality-of-Life Scale (XeQoLS) into Italian language (XeQoLS-IT). Xerostomia is the most relevant acute and late toxicity in patients with head and neck cancer treated with radiotherapy (RT). Patient-reported outcome (PRO) instruments are subjective report on patient perception of health status. The XeQoLS consists of 15 items and measures the impact of salivary gland dysfunction and xerostomia on the four major domains of oral health-related QoL. The XeQoLS-IT was created through a linguistic validation multi-step process: forward translation (TF), backward translation (TB) and administration of the questionnaire to 35 Italian patients with head and neck cancer. Translation was independently carried out by two radiation oncologists who were Italian native speakers. The two versions were compared and adapted to obtain a reconciled version, version 1 (V1). V1 was translated back into English by an Italian pro skilled in teaching English. After review of discrepancies and choice of the most appropriate wording for clarity and similarity to the original, version 2 (V2) was reached by consensus. To evaluate version 2, patients completed the XeQoLS-IT questionnaire and also underwent a cognitive debriefing. The questionnaire was considered simple by the patients. The clarity of the instructions and the easiness to answer questions had a mean value of 4.5 (± 0.71) on a scale from 1 to 5. A valid multi-step process led to the creation of the final version of the XeQoLS-IT, a suitable instrument for the perception of xerostomia in patients treated with RT.

  16. Feasibility, tolerability and safety of pediatric hyperpolarized {sup 129}Xe magnetic resonance imaging in healthy volunteers and children with cystic fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Walkup, Laura L.; Watters, Erin; Ruppert, Kai [Cincinnati Children' s Hospital Medical Center, Center for Pulmonary Imaging Research, Division of Pulmonary Medicine and Department of Radiology, Cincinnati, OH (United States); Thomen, Robert P.; Woods, Jason C. [Cincinnati Children' s Hospital Medical Center, Center for Pulmonary Imaging Research, Division of Pulmonary Medicine and Department of Radiology, Cincinnati, OH (United States); Washington University in St. Louis, Department of Physics, St. Louis, MO (United States); Akinyi, Teckla G.; Cleveland, Zackary I. [Cincinnati Children' s Hospital Medical Center, Center for Pulmonary Imaging Research, Division of Pulmonary Medicine and Department of Radiology, Cincinnati, OH (United States); University of Cincinnati, Biomedical Engineering Program, Cincinnati, OH (United States); Clancy, John P. [Cincinnati Children' s Hospital Medical Center, Division of Pulmonary Medicine, Cincinnati, OH (United States)

    2016-11-15

    Hyperpolarized {sup 129}Xe is a promising contrast agent for MRI of pediatric lung function, but its safety and tolerability in children have not been rigorously assessed. To assess the feasibility, safety and tolerability of hyperpolarized {sup 129}Xe gas as an inhaled contrast agent for pediatric pulmonary MRI in healthy control subjects and in children with cystic fibrosis. Seventeen healthy control subjects (ages 6-15 years, 11 boys) and 11 children with cystic fibrosis (ages 8-16 years, 4 boys) underwent {sup 129}Xe MRI, receiving up to three doses of {sup 129}Xe gas prepared by either a commercially available or a homebuilt {sup 129}Xe polarizer. Subject heart rate and SpO{sub 2} were monitored for 2 min post inhalation and compared to resting baseline values. Adverse events were reported via follow-up phone call at days 1 and 30 (range ±7 days) post-MRI. All children tolerated multiple doses of {sup 129}Xe, and no children withdrew from the study. Relative to baseline, most children who received a full dose of gas for imaging (10 of 12 controls and 8 of 11 children with cystic fibrosis) experienced a nadir in SpO{sub 2} (mean -6.0 ± standard deviation 7.2%, P≤0.001); however within 2 min post inhalation SpO{sub 2} values showed no significant difference from baseline (P=0.11). There was a slight elevation in heart rate (mean +6.6 ± 13.9 beats per minute [bpm], P=0.021), which returned from baseline within 2 min post inhalation (P=0.35). Brief side effects related to the anesthetic properties of xenon were mild and quickly resolved without intervention. No serious or severe adverse events were observed; in total, four minor adverse events (14.3%) were reported following {sup 129}Xe MRI, but all were deemed unrelated to the study. The feasibility, safety and tolerability of {sup 129}Xe MRI has been assessed in a small group of children as young as 6 years. SpO{sub 2} changes were consistent with the expected physiological effects of a short anoxic breath

  17. Xe-135 and Sm-149 Isotopic Evolution Analysis Xesamo code

    International Nuclear Information System (INIS)

    Caro, R.; Gallego, J.; Martinez Fanegas, R.

    1977-01-01

    In this report the time evolution analysis of the nuclides concentration Xe-135 and Sm-149 as a function of the neutron flux is carried out. The neutron flux may be any function of time. It is analyzed as well the reactivity changes associated with the xenon and samarium concentration variations. (Author) 5 refs

  18. Pulmonary hyperpolarized (129) Xe morphometry for mapping xenon gas concentrations and alveolar oxygen partial pressure: Proof-of-concept demonstration in healthy and COPD subjects.

    Science.gov (United States)

    Ouriadov, A; Farag, A; Kirby, M; McCormack, D G; Parraga, G; Santyr, G E

    2015-12-01

    Diffusion-weighted (DW) hyperpolarized (129) Xe morphometry magnetic resonance imaging (MRI) can be used to map regional differences in lung tissue micro-structure. We aimed to generate absolute xenon concentration ([Xe]) and alveolar oxygen partial pressure (pA O2 ) maps by extracting the unrestricted diffusion coefficient (D0 ) of xenon as a morphometric parameter. In this proof-of-concept demonstration, morphometry was performed using multi b-value (0, 12, 20, 30 s/cm(2) ) DW hyperpolarized (129) Xe images obtained in four never-smokers and four COPD ex-smokers. Morphometric parameters and D0 maps were computed and the latter used to generate [Xe] and pA O2 maps. Xenon concentration phantoms estimating a range of values mimicking those observed in vivo were also investigated. Xenon D0 was significantly increased (P = 0.035) in COPD (0.14 ± 0.03 cm(2) /s) compared with never-smokers (0.12 ± 0.02 cm(2) /s). COPD ex-smokers also had significantly decreased [Xe] (COPD = 8 ± 7% versus never-smokers = 13 ± 8%, P = 0.012) and increased pA O2 (COPD = 18 ± 3% versus never-smokers = 15 ± 3%, P = 0.009) compared with never-smokers. Phantom measurements showed the expected dependence of D0 on [Xe] over the range of concentrations anticipated in vivo. DW hyperpolarized (129) Xe MRI morphometry can be used to simultaneously map [Xe] and pA O2 in addition to providing micro-structural biomarkers of emphysematous destruction in COPD. Phantom measurements of D0 ([Xe]) supported the hypotheses that differences in subjects may reflect differences in functional residual capacity. © 2014 Wiley Periodicals, Inc.

  19. Determination of etching parameters for pulsed XeF2 etching of silicon using chamber pressure data

    Science.gov (United States)

    Sarkar, Dipta; Baboly, M. G.; Elahi, M. M.; Abbas, K.; Butner, J.; Piñon, D.; Ward, T. L.; Hieber, Tyler; Schuberth, Austin; Leseman, Z. C.

    2018-04-01

    A technique is presented for determination of the depletion of the etchant, etched depth, and instantaneous etch rate for Si etching with XeF2 in a pulsed etching system in real time. The only experimental data required is the pressure data collected temporally. Coupling the pressure data with the knowledge of the chemical reactions allows for the determination of the etching parameters of interest. Using this technique, it is revealed that pulsed etching processes are nonlinear, with the initial etch rate being the highest and monotonically decreasing as the etchant is depleted. With the pulsed etching system introduced in this paper, the highest instantaneous etch rate of silicon was recorded to be 19.5 µm min-1 for an initial pressure of 1.2 Torr for XeF2. Additionally, the same data is used to determine the rate constant for the reaction of XeF2 with Si; the reaction is determined to be second order in nature. The effect of varying the exposed surface area of Si as well as the effect that pressure has on the instantaneous etch rate as a function of time is shown applying the same technique. As a proof of concept, an AlN resonator is released using XeF2 pulses to remove a sacrificial poly-Si layer.

  20. One-electron spectrum of Xe VIII

    International Nuclear Information System (INIS)

    Roberts, J.R.; Knystautas, E.J.; Sugar, J.

    1979-01-01

    The spectrum of Xe VIII has been observed in a theta-pinch discharge. New line identifications were made that determine the energies of the 6s, 7s, 6p, and 5f terms relative to the 5s 2 S ground state and confirm the previously known 5p and 5d terms. An independent system of levels derived from the observed 4f-ng (n = 5,6) transitions was found. Its position relative to the ground state is obtained from a predicted value for the 5g effective quantum number n*. From the ns series (n=5--7) a value for the ionization enegy of 105.91 +- 0.05 eV was derived

  1. Transverse momentum spectra and nuclear modification factors of charged particles in Xe–Xe collisions at $\\sqrt{s_{\\rm NN}} = 5.44$ TeV

    CERN Document Server

    Acharya, Shreyasi; The ALICE collaboration; Adamova, Dagmar; Adolfsson, Jonatan; Aggarwal, Madan Mohan; Aglieri Rinella, Gianluca; Agnello, Michelangelo; Agrawal, Neelima; Ahammed, Zubayer; Ahn, Sang Un; Aiola, Salvatore; Akindinov, Alexander; Al-turany, Mohammad; Alam, Sk Noor; Silva De Albuquerque, Danilo; Aleksandrov, Dmitry; Alessandro, Bruno; Alfaro Molina, Jose Ruben; Ali, Yasir; Alici, Andrea; Alkin, Anton; Alme, Johan; Alt, Torsten; Altenkamper, Lucas; Altsybeev, Igor; Andrei, Cristian; Andreou, Dimitra; Andrews, Harry Arthur; Andronic, Anton; Angeletti, Massimo; Anguelov, Venelin; Anson, Christopher Daniel; Anticic, Tome; Antinori, Federico; Antonioli, Pietro; Anwar, Rafay; Apadula, Nicole; Aphecetche, Laurent Bernard; Appelshaeuser, Harald; Arcelli, Silvia; Arnaldi, Roberta; Arnold, Oliver Werner; Arsene, Ionut Cristian; Arslandok, Mesut; Audurier, Benjamin; Augustinus, Andre; Averbeck, Ralf Peter; Azmi, Mohd Danish; Badala, Angela; Baek, Yong Wook; Bagnasco, Stefano; Bailhache, Raphaelle Marie; Bala, Renu; Baldisseri, Alberto; Ball, Markus; Baral, Rama Chandra; Barbano, Anastasia Maria; Barbera, Roberto; Barile, Francesco; Barioglio, Luca; Barnafoldi, Gergely Gabor; Barnby, Lee Stuart; Ramillien Barret, Valerie; Bartalini, Paolo; Barth, Klaus; Bartsch, Esther; Bastid, Nicole; Basu, Sumit; Batigne, Guillaume; Batyunya, Boris; Batzing, Paul Christoph; Bazo Alba, Jose Luis; Bearden, Ian Gardner; Beck, Hans; Bedda, Cristina; Behera, Nirbhay Kumar; Belikov, Iouri; Bellini, Francesca; Bello Martinez, Hector; Bellwied, Rene; Espinoza Beltran, Lucina Gabriela; Belyaev, Vladimir; Bencedi, Gyula; Beole, Stefania; Bercuci, Alexandru; Berdnikov, Yaroslav; Berenyi, Daniel; Bertens, Redmer Alexander; Berzano, Dario; Betev, Latchezar; Bhaduri, Partha Pratim; Bhasin, Anju; Bhat, Inayat Rasool; Bhatt, Himani; Bhattacharjee, Buddhadeb; Bhom, Jihyun; Bianchi, Antonio; Bianchi, Livio; Bianchi, Nicola; Bielcik, Jaroslav; Bielcikova, Jana; Bilandzic, Ante; Biro, Gabor; Biswas, Rathijit; Biswas, Saikat; Blair, Justin Thomas; Blau, Dmitry; Blume, Christoph; Boca, Gianluigi; Bock, Friederike; Bogdanov, Alexey; Boldizsar, Laszlo; Bombara, Marek; Bonomi, Germano; Bonora, Matthias; Borel, Herve; Borissov, Alexander; Borri, Marcello; Botta, Elena; Bourjau, Christian; Bratrud, Lars; Braun-munzinger, Peter; Bregant, Marco; Broker, Theo Alexander; Broz, Michal; Brucken, Erik Jens; Bruna, Elena; Bruno, Giuseppe Eugenio; Budnikov, Dmitry; Buesching, Henner; Bufalino, Stefania; Buhler, Paul; Buncic, Predrag; Busch, Oliver; Buthelezi, Edith Zinhle; Bashir Butt, Jamila; Buxton, Jesse Thomas; Cabala, Jan; Caffarri, Davide; Caines, Helen Louise; Caliva, Alberto; Calvo Villar, Ernesto; Soto Camacho, Rabi; Camerini, Paolo; Capon, Aaron Allan; Carena, Francesco; Carena, Wisla; Carnesecchi, Francesca; Castillo Castellanos, Javier Ernesto; Castro, Andrew John; Casula, Ester Anna Rita; Ceballos Sanchez, Cesar; Chandra, Sinjini; Chang, Beomsu; Chang, Wan; Chapeland, Sylvain; Chartier, Marielle; Chattopadhyay, Subhasis; Chattopadhyay, Sukalyan; Chauvin, Alex; Cheshkov, Cvetan Valeriev; Cheynis, Brigitte; Chibante Barroso, Vasco Miguel; Dobrigkeit Chinellato, David; Cho, Soyeon; Chochula, Peter; Chowdhury, Tasnuva; Christakoglou, Panagiotis; Christensen, Christian Holm; Christiansen, Peter; Chujo, Tatsuya; Chung, Suh-urk; Cicalo, Corrado; Cifarelli, Luisa; Cindolo, Federico; Cleymans, Jean Willy Andre; Colamaria, Fabio Filippo; Colella, Domenico; Collu, Alberto; Colocci, Manuel; Concas, Matteo; Conesa Balbastre, Gustavo; Conesa Del Valle, Zaida; Contreras Nuno, Jesus Guillermo; Cormier, Thomas Michael; Corrales Morales, Yasser; Cortese, Pietro; Cosentino, Mauro Rogerio; Costa, Filippo; Costanza, Susanna; Crkovska, Jana; Crochet, Philippe; Cuautle Flores, Eleazar; Cunqueiro Mendez, Leticia; Dahms, Torsten; Dainese, Andrea; Danisch, Meike Charlotte; Danu, Andrea; Das, Debasish; Das, Indranil; Das, Supriya; Dash, Ajay Kumar; Dash, Sadhana; De, Sudipan; De Caro, Annalisa; De Cataldo, Giacinto; De Conti, Camila; De Cuveland, Jan; De Falco, Alessandro; De Gruttola, Daniele; De Marco, Nora; De Pasquale, Salvatore; Derradi De Souza, Rafael; Franz Degenhardt, Hermann; Deisting, Alexander; Deloff, Andrzej; Delsanto, Silvia; Deplano, Caterina; Dhankher, Preeti; Di Bari, Domenico; Di Mauro, Antonio; Di Ruzza, Benedetto; Arteche Diaz, Raul; Dietel, Thomas; Dillenseger, Pascal; Ding, Yanchun; Divia, Roberto; Djuvsland, Oeystein; Dobrin, Alexandru Florin; Domenicis Gimenez, Diogenes; Donigus, Benjamin; Dordic, Olja; Van Doremalen, Lennart Vincent; Dubey, Anand Kumar; Dubla, Andrea; Ducroux, Laurent; Dudi, Sandeep; Duggal, Ashpreet Kaur; Dukhishyam, Mallick; Dupieux, Pascal; Ehlers Iii, Raymond James; Elia, Domenico; Endress, Eric; Engel, Heiko; Epple, Eliane; Erazmus, Barbara Ewa; Erhardt, Filip; Ersdal, Magnus Rentsch; Espagnon, Bruno; Eulisse, Giulio; Eum, Jongsik; Evans, David; Evdokimov, Sergey; Fabbietti, Laura; Faggin, Mattia; Faivre, Julien; Fantoni, Alessandra; Fasel, Markus; Feldkamp, Linus; Feliciello, Alessandro; Feofilov, Grigorii; Fernandez Tellez, Arturo; Ferretti, Alessandro; Festanti, Andrea; Feuillard, Victor Jose Gaston; Figiel, Jan; Araujo Silva Figueredo, Marcel; Filchagin, Sergey; Finogeev, Dmitry; Fionda, Fiorella; Fiorenza, Gabriele; Floris, Michele; Foertsch, Siegfried Valentin; Foka, Panagiota; Fokin, Sergey; Fragiacomo, Enrico; Francescon, Andrea; Francisco, Audrey; Frankenfeld, Ulrich Michael; Fronze, Gabriele Gaetano; Fuchs, Ulrich; Furget, Christophe; Furs, Artur; Fusco Girard, Mario; Gaardhoeje, Jens Joergen; Gagliardi, Martino; Gago Medina, Alberto Martin; Gajdosova, Katarina; Gallio, Mauro; Duarte Galvan, Carlos; Ganoti, Paraskevi; Garabatos Cuadrado, Jose; Garcia-solis, Edmundo Javier; Garg, Kunal; Gargiulo, Corrado; Gasik, Piotr Jan; Gauger, Erin Frances; De Leone Gay, Maria Beatriz; Germain, Marie; Ghosh, Jhuma; Ghosh, Premomoy; Ghosh, Sanjay Kumar; Gianotti, Paola; Giubellino, Paolo; Giubilato, Piero; Glassel, Peter; Gomez Coral, Diego Mauricio; Gomez Ramirez, Andres; Gonzalez, Victor; Gonzalez Zamora, Pedro; Gorbunov, Sergey; Gorlich, Lidia Maria; Gotovac, Sven; Grabski, Varlen; Graczykowski, Lukasz Kamil; Graham, Katie Leanne; Greiner, Leo Clifford; Grelli, Alessandro; Grigoras, Costin; Grigoryev, Vladislav; Grigoryan, Ara; Grigoryan, Smbat; Gronefeld, Julius Maximilian; Grosa, Fabrizio; Grosse-oetringhaus, Jan Fiete; Grosso, Raffaele; Guernane, Rachid; Guerzoni, Barbara; Guittiere, Manuel; Gulbrandsen, Kristjan Herlache; Gunji, Taku; Gupta, Anik; Gupta, Ramni; Bautista Guzman, Irais; Haake, Rudiger; Habib, Michael Karim; Hadjidakis, Cynthia Marie; Hamagaki, Hideki; Hamar, Gergoe; Hamon, Julien Charles; Hannigan, Ryan; Haque, Md Rihan; Harris, John William; Harton, Austin Vincent; Hassan, Hadi; Hatzifotiadou, Despina; Hayashi, Shinichi; Heckel, Stefan Thomas; Hellbar, Ernst; Helstrup, Haavard; Herghelegiu, Andrei Ionut; Gonzalez Hernandez, Emma; Herrera Corral, Gerardo Antonio; Herrmann, Florian; Hetland, Kristin Fanebust; Hilden, Timo Eero; Hillemanns, Hartmut; Hills, Christopher; Hippolyte, Boris; Hohlweger, Bernhard; Horak, David; Hornung, Sebastian; Hosokawa, Ritsuya; Hristov, Peter Zahariev; Huang, Chun-lu; Hughes, Charles; Huhn, Patrick; Humanic, Thomas; Hushnud, Hushnud; Hussain, Nur; Hussain, Tahir; Hutter, Dirk; Hwang, Dae Sung; Iddon, James Philip; Iga Buitron, Sergio Arturo; Ilkaev, Radiy; Inaba, Motoi; Ippolitov, Mikhail; Islam, Md Samsul; Ivanov, Marian; Ivanov, Vladimir; Izucheev, Vladimir; Jacak, Barbara; Jacazio, Nicolo; Jacobs, Peter Martin; Jadhav, Manoj Bhanudas; Jadlovska, Slavka; Jadlovsky, Jan; Jaelani, Syaefudin; Jahnke, Cristiane; Jakubowska, Monika Joanna; Janik, Malgorzata Anna; Jena, Chitrasen; Jercic, Marko; Jimenez Bustamante, Raul Tonatiuh; Jin, Muqing; Jones, Peter Graham; Jusko, Anton; Kalinak, Peter; Kalweit, Alexander Philipp; Kang, Ju Hwan; Kaplin, Vladimir; Kar, Somnath; Karasu Uysal, Ayben; Karavichev, Oleg; Karavicheva, Tatiana; Karczmarczyk, Przemyslaw; Karpechev, Evgeny; Kebschull, Udo Wolfgang; Keidel, Ralf; Keijdener, Darius Laurens; Keil, Markus; Ketzer, Bernhard Franz; Khabanova, Zhanna; Khan, Shaista; Khan, Shuaib Ahmad; Khanzadeev, Alexei; Kharlov, Yury; Khatun, Anisa; Khuntia, Arvind; Kielbowicz, Miroslaw Marek; Kileng, Bjarte; Kim, Byungchul; Kim, Daehyeok; Kim, Dong Jo; Kim, Eun Joo; Kim, Hyeonjoong; Kim, Jinsook; Kim, Jiyoung; Kim, Minjung; Kim, Se Yong; Kim, Taejun; Kim, Taesoo; Kirsch, Stefan; Kisel, Ivan; Kiselev, Sergey; Kisiel, Adam Ryszard; Klay, Jennifer Lynn; Klein, Carsten; Klein, Jochen; Klein-boesing, Christian; Klewin, Sebastian; Kluge, Alexander; Knichel, Michael Linus; Knospe, Anders Garritt; Kobdaj, Chinorat; Varga-kofarago, Monika; Kohler, Markus Konrad; Kollegger, Thorsten; Kondratyeva, Natalia; Kondratyuk, Evgeny; Konevskikh, Artem; Konyushikhin, Maxim; Kovalenko, Oleksandr; Kovalenko, Vladimir; Kowalski, Marek; Kralik, Ivan; Kravcakova, Adela; Kreis, Lukas; Krivda, Marian; Krizek, Filip; Kruger, Mario; Kryshen, Evgeny; Krzewicki, Mikolaj; Kubera, Andrew Michael; Kucera, Vit; Kuhn, Christian Claude; Kuijer, Paulus Gerardus; Kumar, Jitendra; Kumar, Lokesh; Kumar, Shyam; Kundu, Sourav; Kurashvili, Podist; Kurepin, Alexander; Kurepin, Alexey; Kuryakin, Alexey; Kushpil, Svetlana; Kweon, Min Jung; Kwon, Youngil; La Pointe, Sarah Louise; La Rocca, Paola; Lai, Yue Shi; Lakomov, Igor; Langoy, Rune; Lapidus, Kirill; Lara Martinez, Camilo Ernesto; Lardeux, Antoine Xavier; Larionov, Pavel; Laudi, Elisa; Lavicka, Roman; Lea, Ramona; Leardini, Lucia; Lee, Seongjoo; Lehas, Fatiha; Lehner, Sebastian; Lehrbach, Johannes; Lemmon, Roy Crawford; Leogrande, Emilia; Leon Monzon, Ildefonso; Levai, Peter; Li, Xiaomei; Li, Xing Long; Lien, Jorgen Andre; Lietava, Roman; Lim, Bong-hwi; Lindal, Svein; Lindenstruth, Volker; Lindsay, Scott William; Lippmann, Christian; Lisa, Michael Annan; Litichevskyi, Vladyslav; Liu, Alwina; Ljunggren, Hans Martin; Llope, William; Lodato, Davide Francesco; Loginov, Vitaly; Loizides, Constantinos; Loncar, Petra; Lopez, Xavier Bernard; Lopez Torres, Ernesto; Lowe, Andrew John; Luettig, Philipp Johannes; Luhder, Jens Robert; Lunardon, Marcello; Luparello, Grazia; Lupi, Matteo; Maevskaya, Alla; Mager, Magnus; Mahmood, Sohail Musa; Maire, Antonin; Majka, Richard Daniel; Malaev, Mikhail; Malik, Qasim Waheed; Malinina, Liudmila; Mal'kevich, Dmitry; Malzacher, Peter; Mamonov, Alexander; Manko, Vladislav; Manso, Franck; Manzari, Vito; Mao, Yaxian; Marchisone, Massimiliano; Mares, Jiri; Margagliotti, Giacomo Vito; Margotti, Anselmo; Margutti, Jacopo; Marin, Ana Maria; Markert, Christina; Marquard, Marco; Martin, Nicole Alice; Martinengo, Paolo; Martinez Hernandez, Mario Ivan; Martinez-garcia, Gines; Martinez Pedreira, Miguel; Masciocchi, Silvia; Masera, Massimo; Masoni, Alberto; Massacrier, Laure Marie; Masson, Erwann; Mastroserio, Annalisa; Mathis, Andreas Michael; Toledo Matuoka, Paula Fernanda; Matyja, Adam Tomasz; Mayer, Christoph; Mazzilli, Marianna; Mazzoni, Alessandra Maria; Meddi, Franco; Melikyan, Yuri; Menchaca-rocha, Arturo Alejandro; Meninno, Elisa; Mercado-perez, Jorge; Meres, Michal; Soncco Meza, Carlos; Mhlanga, Sibaliso; Miake, Yasuo; Micheletti, Luca; Mieskolainen, Matti Mikael; Mihaylov, Dimitar Lubomirov; Mikhaylov, Konstantin; Mischke, Andre; Mishra, Aditya Nath; Miskowiec, Dariusz Czeslaw; Mitra, Jubin; Mitu, Ciprian Mihai; Mohammadi, Naghmeh; Mohanty, Auro Prasad; Mohanty, Bedangadas; Khan, Mohammed Mohisin; Moreira De Godoy, Denise Aparecida; Perez Moreno, Luis Alberto; Moretto, Sandra; Morreale, Astrid; Morsch, Andreas; Muccifora, Valeria; Mudnic, Eugen; Muhlheim, Daniel Michael; Muhuri, Sanjib; Mukherjee, Maitreyee; Mulligan, James Declan; Gameiro Munhoz, Marcelo; Munning, Konstantin; Arratia Munoz, Miguel Ignacio; Munzer, Robert Helmut; Murakami, Hikari; Murray, Sean; Musa, Luciano; Musinsky, Jan; Myers, Corey James; Myrcha, Julian Wojciech; Naik, Bharati; Nair, Rahul; Nandi, Basanta Kumar; Nania, Rosario; Nappi, Eugenio; Narayan, Amrendra; Naru, Muhammad Umair; Nassirpour, Adrian Fereydon; Ferreira Natal Da Luz, Pedro Hugo; Nattrass, Christine; Rosado Navarro, Sebastian; Nayak, Kishora; Nayak, Ranjit; Nayak, Tapan Kumar; Nazarenko, Sergey; Negrao De Oliveira, Renato Aparecido; Nellen, Lukas; Nesbo, Simon Voigt; Neskovic, Gvozden; Ng, Fabian; Nicassio, Maria; Niedziela, Jeremi; Nielsen, Borge Svane; Nikolaev, Sergey; Nikulin, Sergey; Nikulin, Vladimir; Noferini, Francesco; Nomokonov, Petr; Nooren, Gerardus; Cabanillas Noris, Juan Carlos; Norman, Jaime; Nyanin, Alexander; Nystrand, Joakim Ingemar; Oh, Hoonjung; Ohlson, Alice Elisabeth; Oleniacz, Janusz; Oliveira Da Silva, Antonio Carlos; Oliver, Michael Henry; Onderwaater, Jacobus; Oppedisano, Chiara; Orava, Risto; Oravec, Matej; Ortiz Velasquez, Antonio; Oskarsson, Anders Nils Erik; Otwinowski, Jacek Tomasz; Oyama, Ken; Pachmayer, Yvonne Chiara; Pacik, Vojtech; Pagano, Davide; Paic, Guy; Palni, Prabhakar; Pan, Jinjin; Pandey, Ashutosh Kumar; Panebianco, Stefano; Papikyan, Vardanush; Pareek, Pooja; Park, Jonghan; Parkkila, Jasper Elias; Parmar, Sonia; Passfeld, Annika; Pathak, Surya Prakash; Patra, Rajendra Nath; Paul, Biswarup; Pei, Hua; Peitzmann, Thomas; Peng, Xinye; Pereira, Luis Gustavo; Pereira Da Costa, Hugo Denis Antonio; Peresunko, Dmitry Yurevich; Perez Lezama, Edgar; Peskov, Vladimir; Pestov, Yury; Petracek, Vojtech; Petrovici, Mihai; Petta, Catia; Peretti Pezzi, Rafael; Piano, Stefano; Pikna, Miroslav; Pillot, Philippe; Ozelin De Lima Pimentel, Lais; Pinazza, Ombretta; Pinsky, Lawrence; Pisano, Silvia; Piyarathna, Danthasinghe; Ploskon, Mateusz Andrzej; Planinic, Mirko; Pliquett, Fabian; Pluta, Jan Marian; Pochybova, Sona; Podesta Lerma, Pedro Luis Manuel; Poghosyan, Martin; Polishchuk, Boris; Poljak, Nikola; Poonsawat, Wanchaloem; Pop, Amalia; Poppenborg, Hendrik; Porteboeuf, Sarah Julie; Pozdniakov, Valeriy; Prasad, Sidharth Kumar; Preghenella, Roberto; Prino, Francesco; Pruneau, Claude Andre; Pshenichnov, Igor; Puccio, Maximiliano; Punin, Valery; Putschke, Jorn Henning; Raha, Sibaji; Rajput, Sonia; Rak, Jan; Rakotozafindrabe, Andry Malala; Ramello, Luciano; Rami, Fouad; Raniwala, Rashmi; Raniwala, Sudhir; Rasanen, Sami Sakari; Rascanu, Bogdan Theodor; Ratza, Viktor; Ravasenga, Ivan; Read, Kenneth Francis; Redlich, Krzysztof; Rehman, Attiq Ur; Reichelt, Patrick Simon; Reidt, Felix; Ren, Xiaowen; Renfordt, Rainer Arno Ernst; Reshetin, Andrey; Revol, Jean-pierre; Reygers, Klaus Johannes; Riabov, Viktor; Richert, Tuva Ora Herenui; Richter, Matthias Rudolph; Riedler, Petra; Riegler, Werner; Riggi, Francesco; Ristea, Catalin-lucian; Rode, Sudhir Pandurang; Rodriguez Cahuantzi, Mario; Roeed, Ketil; Rogalev, Roman; Rogochaya, Elena; Rohr, David Michael; Roehrich, Dieter; Rokita, Przemyslaw Stefan; Ronchetti, Federico; Dominguez Rosas, Edgar; Roslon, Krystian; Rosnet, Philippe; Rossi, Andrea; Rotondi, Alberto; Roukoutakis, Filimon; Roy, Christelle Sophie; Roy, Pradip Kumar; Vazquez Rueda, Omar; Rui, Rinaldo; Rumyantsev, Boris; Rustamov, Anar; Ryabinkin, Evgeny; Ryabov, Yury; Rybicki, Andrzej; Saarinen, Sampo; Sadhu, Samrangy; Sadovskiy, Sergey; Safarik, Karel; Saha, Sumit Kumar; Sahoo, Baidyanath; Sahoo, Pragati; Sahoo, Raghunath; Sahoo, Sarita; Sahu, Pradip Kumar; Saini, Jogender; Sakai, Shingo; Saleh, Mohammad Ahmad; Sambyal, Sanjeev Singh; Samsonov, Vladimir; Sandoval, Andres; Sarkar, Amal; Sarkar, Debojit; Sarkar, Nachiketa; Sarma, Pranjal; Sas, Mike Henry Petrus; Scapparone, Eugenio; Scarlassara, Fernando; Schaefer, Brennan; Scheid, Horst Sebastian; Schiaua, Claudiu Cornel; Schicker, Rainer Martin; Schmidt, Christian Joachim; Schmidt, Hans Rudolf; Schmidt, Marten Ole; Schmidt, Martin; Schmidt, Nicolas Vincent; Schukraft, Jurgen; Schutz, Yves Roland; Schwarz, Kilian Eberhard; Schweda, Kai Oliver; Scioli, Gilda; Scomparin, Enrico; Sefcik, Michal; Seger, Janet Elizabeth; Sekiguchi, Yuko; Sekihata, Daiki; Selyuzhenkov, Ilya; Senosi, Kgotlaesele; Senyukov, Serhiy; Serradilla Rodriguez, Eulogio; Sett, Priyanka; Sevcenco, Adrian; Shabanov, Arseniy; Shabetai, Alexandre; Shahoyan, Ruben; Shaikh, Wadut; Shangaraev, Artem; Sharma, Anjali; Sharma, Ankita; Sharma, Meenakshi; Sharma, Natasha; Sheikh, Ashik Ikbal; Shigaki, Kenta; Shimomura, Maya; Shirinkin, Sergey; Shou, Qiye; Shtejer Diaz, Katherin; Sibiryak, Yury; Siddhanta, Sabyasachi; Sielewicz, Krzysztof Marek; Siemiarczuk, Teodor; Silvermyr, David Olle Rickard; Simatovic, Goran; Simonetti, Giuseppe; Singaraju, Rama Narayana; Singh, Ranbir; Singh, Randhir; Singhal, Vikas; Sarkar - Sinha, Tinku; Sitar, Branislav; Sitta, Mario; Skaali, Bernhard; Slupecki, Maciej; Smirnov, Nikolai; Snellings, Raimond; Snellman, Tomas Wilhelm; Song, Jihye; Soramel, Francesca; Sorensen, Soren Pontoppidan; Sozzi, Federica; Sputowska, Iwona Anna; Stachel, Johanna; Stan, Ionel; Stankus, Paul; Stenlund, Evert Anders; Stocco, Diego; Storetvedt, Maksim Melnik; Strmen, Peter; Alarcon Do Passo Suaide, Alexandre; Sugitate, Toru; Suire, Christophe Pierre; Suleymanov, Mais Kazim Oglu; Suljic, Miljenko; Sultanov, Rishat; Sumbera, Michal; Sumowidagdo, Suharyo; Suzuki, Ken; Swain, Sagarika; Szabo, Alexander; Szarka, Imrich; Tabassam, Uzma; Takahashi, Jun; Tambave, Ganesh Jagannath; Tanaka, Naoto; Tarhini, Mohamad; Tariq, Mohammad; Tarzila, Madalina-gabriela; Tauro, Arturo; Tejeda Munoz, Guillermo; Telesca, Adriana; Terrevoli, Cristina; Teyssier, Boris; Thakur, Dhananjaya; Thakur, Sanchari; Thomas, Deepa; Thoresen, Freja; Tieulent, Raphael Noel; Tikhonov, Anatoly; Timmins, Anthony Robert; Toia, Alberica; Topilskaya, Nataliya; Toppi, Marco; Rojas Torres, Solangel; Tripathy, Sushanta; Trogolo, Stefano; Trombetta, Giuseppe; Tropp, Lukas; Trubnikov, Victor; Trzaska, Wladyslaw Henryk; Trzcinski, Tomasz Piotr; Trzeciak, Barbara Antonina; Tsuji, Tomoya; Tumkin, Alexandr; Turrisi, Rosario; Tveter, Trine Spedstad; Ullaland, Kjetil; Umaka, Ejiro Naomi; Uras, Antonio; Usai, Gianluca; Utrobicic, Antonija; Vala, Martin; Van Hoorne, Jacobus Willem; Van Leeuwen, Marco; Vande Vyvre, Pierre; Varga, Dezso; Diozcora Vargas Trevino, Aurora; Vargyas, Marton; Varma, Raghava; Vasileiou, Maria; Vasiliev, Andrey; Vauthier, Astrid; Vazquez Doce, Oton; Vechernin, Vladimir; Veen, Annelies Marianne; Vercellin, Ermanno; Vergara Limon, Sergio; Vermunt, Luuk; Vernet, Renaud; Vertesi, Robert; Vickovic, Linda; Viinikainen, Jussi Samuli; Vilakazi, Zabulon; Villalobos Baillie, Orlando; Villatoro Tello, Abraham; Vinogradov, Alexander; Virgili, Tiziano; Vislavicius, Vytautas; Vodopyanov, Alexander; Volkl, Martin Andreas; Voloshin, Kirill; Voloshin, Sergey; Volpe, Giacomo; Von Haller, Barthelemy; Vorobyev, Ivan; Voscek, Dominik; Vranic, Danilo; Vrlakova, Janka; Wagner, Boris; Wang, Hongkai; Wang, Mengliang; Watanabe, Yosuke; Weber, Michael; Weber, Steffen Georg; Wegrzynek, Adam; Weiser, Dennis Franz; Wenzel, Sandro Christian; Wessels, Johannes Peter; Westerhoff, Uwe; Whitehead, Andile Mothegi; Wiechula, Jens; Wikne, Jon; Wilk, Grzegorz Andrzej; Wilkinson, Jeremy John; Willems, Guido Alexander; Williams, Crispin; Willsher, Emily; Windelband, Bernd Stefan; Witt, William Edward; Xu, Ran; Yalcin, Serpil; Yamakawa, Kosei; Yano, Satoshi; Yin, Zhongbao; Yokoyama, Hiroki; Yoo, In-kwon; Yoon, Jin Hee; Yurchenko, Volodymyr; Zaccolo, Valentina; Zaman, Ali; Zampolli, Chiara; Correa Zanoli, Henrique Jose; Zardoshti, Nima; Zarochentsev, Andrey; Zavada, Petr; Zavyalov, Nikolay; Zbroszczyk, Hanna Paulina; Zhalov, Mikhail; Zhang, Xiaoming; Zhang, Yonghong; Zhang, Zuman; Zhao, Chengxin; Zherebchevskii, Vladimir; Zhigareva, Natalia; Zhou, Daicui; Zhou, You; Zhou, Zhuo; Zhu, Hongsheng; Zhu, Jianhui; Zhu, Ya; Zichichi, Antonino; Zimmermann, Markus Bernhard; Zinovjev, Gennady; Zmeskal, Johann; Zou, Shuguang

    2018-01-01

    Transverse momentum ($p_{\\rm T}$ ) spectra of charged particles at mid-pseudorapidity in Xe-Xe collisions at $\\sqrt{s_{\\rm NN}} = 5.44$ TeV measured with the ALICE apparatus at the Large Hadron Collider are reported. The kinematic range $0.15 10$ GeV/$c$. This similarity is qualitatively consistent with the expected quadratic path length dependence of medium-induced radiative energy loss of a parton propagating in the medium. The centrality dependence of the ratio of the average transverse momentum $p_{\\rm T}$ in Xe-Xe collisions over Pb-Pb collisions at $\\sqrt{s_{\\rm NN}} = 5.02$ TeV is compared to hydrodynamical model calculations.

  2. Xe-133 accumulation in fatty liver: hepatic uptake and washout correlated with pulmonary and mesenteric retention

    International Nuclear Information System (INIS)

    Samuels, L.D.

    1980-01-01

    Xe-133 uptake in patients with fatty livers is described and compared with uptake and retention in lungs, blood and mesenteric fat and with normal hepatic uptake. In the absence of obstructive lung disease or excessive obesity, Xe-133 uptake and retention is a valuable means of screening patients for the presence of fatty liver. Although non-specific for the etiology of fatty liver, the test is an effective and non-invasive method of detection which merits further application. (author)

  3. Effects of exposure to 2100 MHz GSM-like radiofrequency electromagnetic field on auditory system of rats

    Directory of Open Access Journals (Sweden)

    Metin Çeliker

    Full Text Available Abstract Introduction: The use of mobile phones has become widespread in recent years. Although beneficial from the communication viewpoint, the electromagnetic fields generated by mobile phones may cause unwanted biological changes in the human body. Objective: In this study, we aimed to evaluate the effects of 2100 MHz Global System for Mobile communication (GSM-like electromagnetic field, generated by an electromagnetic fields generator, on the auditory system of rats by using electrophysiological, histopathologic and immunohistochemical methods. Methods: Fourteen adult Wistar albino rats were included in the study. The rats were divided randomly into two groups of seven rats each. The study group was exposed continuously for 30 days to a 2100 MHz electromagnetic fields with a signal level (power of 5.4 dBm (3.47 mW to simulate the talk mode on a mobile phone. The control group was not exposed to the aforementioned electromagnetic fields. After 30 days, the Auditory Brainstem Responses of both groups were recorded and the rats were sacrificed. The cochlear nuclei were evaluated by histopathologic and immunohistochemical methods. Results: The Auditory Brainstem Responses records of the two groups did not differ significantly. The histopathologic analysis showed increased degeneration signs in the study group (p = 0.007. In addition, immunohistochemical analysis revealed increased apoptotic index in the study group compared to that in the control group (p = 0.002. Conclusion: The results support that long-term exposure to a GSM-like 2100 MHz electromagnetic fields causes an increase in neuronal degeneration and apoptosis in the auditory system.

  4. Algorithms on Flag Manifolds for Knowledge Discovery in N-way Arrays

    Science.gov (United States)

    2015-11-20

    subspace representations. For instance, the d- dimensional subspace in the flag corresponds to the extrinsic manifold mean. When the set of subspaces is...one-dimensional subspace of V and let θ(L, Vi) denote the principal angle between L and Vi. Motivated by a problem in data analysis, we seek an L that...appear less frequently in the literature may be more appropriate for certain tasks. The extrinsic manifold mean, the L 2-median, and the ag mean are

  5. NMR and MRI of continuously dissolved hyperpolarized {sup 129}Xe by means of hollow fibers

    Energy Technology Data Exchange (ETDEWEB)

    Amor, Nadia; Kueppers, Markus; Bluemich, Bernhard [ITMC of RWTH Aachen University (Germany); Hamilton, Kathrin; Schmitz-Rode, Thomas; Steinseifer, Ulrich [HIA of RWTH Aachen University (Germany); Appelt, Stephan [Research Center Juelich (Germany)

    2011-07-01

    Various methods of hyperpolarizing (HP) spin systems have been developed during the last years to increase the intrinsically low sensitivity of NMR by several orders of magnitude. Among them is the hyperpolarization of {sup 129}Xe via Spin Exchange Optical Pumping (SEOP). NMR of HP {sup 129}Xe is of great interest because of its good solubility and its very sensitive chemical shift. The main obstacle for many applications is the efficient and continuous dissolution into carrier agents without formation of foams or bubbles. It has been overcome by the so-called ''xenonizer'' setups. They mainly consist of commercially available hollow fiber membranes typically used in clinical oxygenators. A purpose-built xenonizer setup has been developed and analyzed in detail by NMR spectroscopy and MRI for varying fiber materials as well as for different fluids, including bio-relevant fluids such as blood, plasma, and erythrocytes. As a result, the xenonizer technology could be further understood and improved, and new applications of HP {sup 129}Xe for medical NMR were explored.

  6. Test of Lorentz symmetry with a {sup 3}He/{sup 129}Xe clock-comparison experiment

    Energy Technology Data Exchange (ETDEWEB)

    Gemmel, Claudia

    2011-01-28

    The minimal Standard Model Extension (SME) of Kostelecky and coworkers, which parametrizes the general treatment of CPT- and Lorentz invariance violation, predicts sidereal modulations of atomic transition frequencies as the Earth rotates relative to a Lorentz-violating background field. One method to search for these modulations is the so-called clock-comparison experiment, where the frequencies of co-located clocks are compared as they rotate with respect to the fixed stars. In this work an experiment is presented where polarized {sup 3}He and {sup 129}Xe gas samples in a glass cell serve as clocks, whose nuclear spin precession frequencies are detected with the help of highly sensitive SQUID sensors inside a magnetically shielded room. The unique feature of this experiment is the fact that the spins are precessing freely, with transverse relaxation times T{sup *}{sub 2} of up to 4.4 h for {sup 129}Xe and 14.1 h for {sup 3}He. To be sensitive to Lorentz-violating effects, the influence of external magnetic fields is canceled via the weighted {sup 3}He/{sup 129}Xe phase difference, {delta}{phi}={phi}{sub he}-({gamma}{sub he})/({gamma}{sub xe}) {phi}{sub xe}. The Lorentz-violating SME parameters for the neutron, b{sup n}{sub X} and b{sup n}{sub Y}, are determined out of a {chi}{sup 2} fit on the phase difference data of 7 spin precession measurements of 12 to 16 hours length. The piecewise defined fit model contains a sine and a cosine term to describe the sidereal modulation, as well as 7 offset terms, 7 linear terms and 7 . 2 exponential terms decreasing with T{sup *}{sub 2,he} and T{sup *}{sub 2,xe}, which are assigned to the respective measurement. The linear term in the weighted phase difference mainly arises from deviations of the gyromagnetic ratios from their literature values due to chemical shifts, while the exponential terms reflect the phase shifts resulting from demagnetization fields in the non-ideally spherical sample cell. The result of the {chi

  7. Evaluation of the absorbed dose to the lungs due to Xe133 and Tc99m (MAA)

    International Nuclear Information System (INIS)

    Vazquez A, M.; Murillo C, F.; Castillo D, C.; Sifuentes D, Y.; Sanchez S, P.; Rojas P, E.; Marquez P, F.

    2015-10-01

    The absorbed dose in lungs of an adult patient has been evaluated using the biokinetics of radiopharmaceuticals containing Xe 133 or Tc 99m (MAA). The absorbed dose was calculated using the MIRD formalism, and the Cristy-and Eckerman lungs model. The absorbed dose in the lungs due to 133 Xe is 0.00104 mGy/MBq. Here, the absorbed dose due to remaining tissue, included in the 133 Xe biokinetics is not significant. The absorbed dose in the lungs, due Tc 99m (MAA), is 0.065 mGy/MBq. Approximately, 4.6% of the absorbed dose is due to organs like liver, kidneys, bladder, and the rest of tissues, included in the Tc 99m biokinetics. Here, the absorbed dose is very significant to be overlooked. The dose contribution is mainly due to photons emitted by the liver. (Author)

  8. Neutron-capture cross-section measurements of Xe136 between 0.4 and 14.8 MeV

    Science.gov (United States)

    Bhike, Megha; Tornow, W.

    2014-03-01

    Fast-neutron-capture cross-section data on Xe136 have been measured with the activation method between 0.4 and 14.8 MeV. The cross section was found to be of the order of 1 mb at the eleven energies investigated. This result is important to interpret potential neutron-induced backgrounds in the enriched xenon observatory and KamLAND-Zen neutrinoless double-β decay searches that use xenon as both source and detector. A high-pressure sphere filled with Xe136 was irradiated with monoenergetic neutrons produced by the reactions 3H(p ,n)3He, 2H(d ,n)3He, and 3H(d ,n)4He. Indium and gold monitor foils were irradiated simultaneously with the Xe136 to determine the incident neutron flux. The activities of the reaction products were measured with high-resolution γ-ray spectroscopy. The present results are compared to predictions from ENDF/B-VII.1 and TENDL-2012.

  9. Evaluation of the absorbed dose to the lungs due to Xe{sup 133} and Tc{sup 99m} (MAA); Evaluacion de la dosis absorbida en los pulmones debido al Xe{sup 133} y Tc{sup 99m} (MAA)

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez A, M.; Murillo C, F.; Castillo D, C.; Sifuentes D, Y.; Sanchez S, P. [Universidad Nacional de Trujillo, Av. Juan Pablo II s/n, Trujillo (Peru); Rojas P, E. [Instituto Peruano de Energia Nuclear, Av. Canada 1470, Lima (Peru); Marquez P, F., E-mail: marvva@hotmail.com [Instituto Nacional de Enfermedades Neoplasicas, Av. Angamos 2520, Lima (Peru)

    2015-10-15

    The absorbed dose in lungs of an adult patient has been evaluated using the biokinetics of radiopharmaceuticals containing Xe{sup 133} or Tc{sup 99m} (MAA). The absorbed dose was calculated using the MIRD formalism, and the Cristy-and Eckerman lungs model. The absorbed dose in the lungs due to {sup 133}Xe is 0.00104 mGy/MBq. Here, the absorbed dose due to remaining tissue, included in the {sup 133}Xe biokinetics is not significant. The absorbed dose in the lungs, due Tc{sup 99m} (MAA), is 0.065 mGy/MBq. Approximately, 4.6% of the absorbed dose is due to organs like liver, kidneys, bladder, and the rest of tissues, included in the Tc{sup 99m} biokinetics. Here, the absorbed dose is very significant to be overlooked. The dose contribution is mainly due to photons emitted by the liver. (Author)

  10. An unusual case of seed dispersal in an invasive aquatic; yellow flag iris (Iris pseudacorus)

    Science.gov (United States)

    Understanding reproductive mode of invasive plants can help managers plan more efficacious control. Invasive aquatics typically reproduce primarily through vegetative means. Yellow flag iris is an invasive plant species often growing as an emergent aquatic. There have been contradictory reports of i...

  11. I-Xe and 40Ar-39Ar dating of silicate from Weekeroo Station and Netschaevo IIE iron meteorites

    International Nuclear Information System (INIS)

    Niemeyer, S.

    1980-01-01

    Silicate inclusions from two IIE iron meteorites were dated by the I-Xe and 40 Ar- 39 Ar techniques. Weekeroo Station, a 'normal' IIE iron, shows no loss of radiogenic 40 Ar at low temperature, and the well defined 40 Ar- 39 Ar plateau yields an age of 4.54 +- 0.03 Byr. The xenon data define a good I-Xe correlation with an age of + 10.9 +- 0.5 Myr relative to Bjurbole. Despite its relatively young age, Weekeroo Station's ( 129 Xe/ 132 Xe)sub(trapped) ratio (= 0.84 +- 0.05) lies significantly below the solar value. Netschaevo silicate has a chondritic composition, unlike 'normal' IIE silicate which is more differentiated. Nevertheless Netschaevo gives a 40 Ar- 39 Ar plateau-age of only 3.79 +- 0.03 Byr, with the xenon data failing to define an I-Xe isochron. Only irons from the IAB and IIE groups contain silicate inclusions, but these two groups differ in many other respects, mostly suggesting that IAB meteorites are more primitive. The I-Xe chronology supports this suggestion inasmuch as Weekeroo Station formed well after IAB silicates. The four silicate-bearing IIE irons which have now been dated can be subdivided into distinct pairs: Weekeroo Station and Colomera formed near the beginning of the solar system, while Netschaevo and Kodaikanal both formed only 3.8 Byr ago. A review of other properties of these meteorites generally supports this subdivision. This work underscores the complexity of the history of IIE meteorites; in particular, an adequate model must account for the formation of two IIE irons at 3.8 Byr without disturbing rare gases in Weekeroo Station. All formation models are quite speculative, but the one which seems best to fit the available evidence postulates two parent bodies: the 3.8 Byr old silicate formed on one parent body, all other IIE material resided in a separate body, and subsequent collision(s) mixed the young silicate with IIE metal. (author)

  12. 133Xe labelling of acrylate for catheter embolisation

    International Nuclear Information System (INIS)

    Endert, G.; Penzel, E.; Ritter, H.; Schumann, E.

    1983-01-01

    A method for radio-nucleide labelling of histo-acryl/lipiodol with 133 Xe gas is described. The method consists of disolving the gas in lipiodol under sterile conditions. After embolisation and angiography, the localisation of the embolising material can be determined by means of a scintillation camera. The labelling method was used in 15 patients. In all patients the position of the embolising material, as demonstrated by scintigraphy, corresponded with the radiological findings. It was not possible to demonstrate escape of the material by scintigraphy. (orig.) [de

  13. Anomalous Photoionization in Xe

    Science.gov (United States)

    Klapisch, Marcel; Busquet, Michel

    2012-10-01

    Photoionization (PI) cross sections are important components of the opacities that are necessary for the simulation of astrophysical and ICF plasmas. Most of PI cross sections (i) start abruptly at threshold and (ii) decrease as an inverse power (e.g.3^rd) of the photon energy. In the framework of the CRASH project [1] we computed Xe opacities with the STA code [2]. We observed that the PI cross section for the 4d shell has neither of these 2 characteristics. We explain this result as interference between the bound 4d wavefunction (wf), the photon, and the free electron wf. Similar, but less pronounced effects are seen for the 5d and 5p shells. Simplified models of PI not involving the actual wf would not show this effect and would probably be inaccurate.[4pt] [1] Doss, F. W., Drake, R. P., and Kuranz, C. C., High Ener. Dens. Phys. 6, 157-61.[0pt] [2] Busquet, M., Klapisch, M., Bar-Shalom, A., et al., Bull. Am. Phys. Soc. 55, 225 (2010).

  14. Feasibility, tolerability and safety of pediatric hyperpolarized "1"2"9Xe magnetic resonance imaging in healthy volunteers and children with cystic fibrosis

    International Nuclear Information System (INIS)

    Walkup, Laura L.; Watters, Erin; Ruppert, Kai; Thomen, Robert P.; Woods, Jason C.; Akinyi, Teckla G.; Cleveland, Zackary I.; Clancy, John P.

    2016-01-01

    Hyperpolarized "1"2"9Xe is a promising contrast agent for MRI of pediatric lung function, but its safety and tolerability in children have not been rigorously assessed. To assess the feasibility, safety and tolerability of hyperpolarized "1"2"9Xe gas as an inhaled contrast agent for pediatric pulmonary MRI in healthy control subjects and in children with cystic fibrosis. Seventeen healthy control subjects (ages 6-15 years, 11 boys) and 11 children with cystic fibrosis (ages 8-16 years, 4 boys) underwent "1"2"9Xe MRI, receiving up to three doses of "1"2"9Xe gas prepared by either a commercially available or a homebuilt "1"2"9Xe polarizer. Subject heart rate and SpO_2 were monitored for 2 min post inhalation and compared to resting baseline values. Adverse events were reported via follow-up phone call at days 1 and 30 (range ±7 days) post-MRI. All children tolerated multiple doses of "1"2"9Xe, and no children withdrew from the study. Relative to baseline, most children who received a full dose of gas for imaging (10 of 12 controls and 8 of 11 children with cystic fibrosis) experienced a nadir in SpO_2 (mean -6.0 ± standard deviation 7.2%, P≤0.001); however within 2 min post inhalation SpO_2 values showed no significant difference from baseline (P=0.11). There was a slight elevation in heart rate (mean +6.6 ± 13.9 beats per minute [bpm], P=0.021), which returned from baseline within 2 min post inhalation (P=0.35). Brief side effects related to the anesthetic properties of xenon were mild and quickly resolved without intervention. No serious or severe adverse events were observed; in total, four minor adverse events (14.3%) were reported following "1"2"9Xe MRI, but all were deemed unrelated to the study. The feasibility, safety and tolerability of "1"2"9Xe MRI has been assessed in a small group of children as young as 6 years. SpO_2 changes were consistent with the expected physiological effects of a short anoxic breath-hold, and other mild side effects were

  15. Energy-Transfer Kinetics for Xe (6p[1/2]0) Atoms in Kr, Ar, Ne, and He.

    Science.gov (United States)

    He, Shan; Liu, Dong; Li, Xueyang; Chu, Junzhi; Guo, Jingwei; Liu, Jinbo; Hu, Shu; Sang, Fengting; Jin, Yuqi

    2018-06-11

    The kinetic processes for the Xe (6p[1/2] 0 ) atoms in Kr, Ar, Ne, and He buffer gases were studied. We found that Kr, Ar, and Ne atoms can be used to switch the amplified spontaneous emission (ASE) channel from 3408 nm (6p[1/2] 0 -6s'[1/2] 1 ) to 3680 nm (5d[1/2] 1 -6p[1/2] 1 ), while Xe and He atoms do not show such a phenomenon. This ASE channel switch is mainly ascribed to the fast transfer of 6p[1/2] 0 → 5d[1/2] 1 . On the basis of the rate equations for two-state coupling (energy-transfer processes between the two states are very rapid), the reason why the ASE channel switch effect normally coincides with a double exponential decay of the spontaneous emission at 828 nm (6p[1/2] 0 -6s[3/2] 1 ) is explained. The actual situations in Xe, Ar, Ne, and He follow this rule. However, the strictly single exponential decay of the spontaneous emission at 828 nm and strong ASE channel switch effect simultaneously emerge in Kr. This indicates that the transfer of 6p[1/2] 0 → 5d[1/2] 1 in Kr does not occur via two-state coupling, but via two steps of near-resonance collision through the 5s[3/2] 2 (Kr) state as the intermediate state (6p[1/2] 0 → 5s[3/2] 2 (Kr) → 5d[1/2] 1 ). In addition, we found Xe (6p[1/2] 0 ) atoms strongly tend to reach the 6p[3/2] 2 , 6p[3/2] 1 , and 6p[5/2] 2 states through the 5s[3/2] 2 (Kr) state as the intermediate state in Kr. The 5s[3/2] 2 (Kr) state plays a very important role in the energy-transfer kinetics for the Xe (6p[1/2] 0 ) atoms. Kr is probably an excellent buffer gas for laser systems based on Xe.

  16. [Regional liver circulation and scintigraphic imaging of portal circulation with 133Xe].

    Science.gov (United States)

    Kroiss, A

    1984-01-01

    Regional hepatic blood flow has been determined by 4 methods with the aid of the 133Xe washout technique: scintisplenoportography (direct application of 133Xe into the spleen by means of a thin needle); arterial method (133Xe is injected into the A. hepatica by means of a catheter); retrograde-venous method (133Xe administered by an occluding hepatic vein catheter); percutaneous intrahepatic method (133Xe administered directly into the parenchyma by means of a Chiba needle). Ad 1.: Scintisplenoportography (SSP) was executed with 97 patients: 8 patients with a healthy liver presented a hepatic blood flow of 103.37 +/- 11.5 ml/100 g/min. 4 patients with a chronic hepatitis showed a hepatic blood flow of 105.67 +/- 10.2 ml/100 g/min. In 38 patients with compensated cirrhosis, hepatic blood flow was determined with 58.15 +/- 11.5 ml/100 g/min and 19 patients with decompensated cirrhosis showed a blood flow of 34.54 +/- 7.2 ml/100 g/min. Of the 19 patients, who did not present any liver image, 2 patients suffered from a prehepatic block, 1 patient (female) from a posthepatic block, the rest were decompensated cirrhoses. In 5 patients suffering from steatosis only collateral circulation was determined and in 4 patients the spleen could not be punctured. In the patients with compensated and decompensated cirrhosis of the liver, hepatic blood flow differentiated significantly (p less than 0.001) from patients with healthy livers and chronic hepatitis. In the patients with bioptically assured steatosis only the washout constant was determined. Reproducibility of this method was tested in 4 patients and no statistical difference of hepatic blood flow values could be found and the correlation coefficient amounted to 0.9856. The advantage of SSP lies in the possibility of recording the portal vein circulation: cranial collaterals were found in 33 patients, 2 patients had caudal collaterals exclusively and 29 patients cranial and caudal collaterals. 33 cirrhosis patients

  17. Analysis of output trends from Varian 2100C/D and 600C/D accelerators

    International Nuclear Information System (INIS)

    Grattan, M W D; Hounsell, A R

    2011-01-01

    Analysis of Varian linear accelerator output trends is reported. Two groups, consisting of four matched Varian 2100C/D and four matched Varian 600C/D accelerators, with different designs of monitor chamber, have been investigated and the data acquired from regular calibrated ion chamber/electrometer measurements of the output performance of the eight accelerators analysed. The trend of machine output with time, having removed the effect of adjusting the monitor chamber response, was compared on a monthly and annual basis for monitor chambers with ages ranging between 1 year and 7 years. The results indicate that the response is generally consistent within each set of accelerators with different monitor chamber designs. Those used in a Varian 600C/D machine result in a reduction in measured output over time, with an average monthly reduction of 0.35 ± 0.09% over the course of the first 4 years of use. The chambers used in a 2100C/D accelerator result in an increase in measured output over time, with an average monthly increase of 0.26 ± 0.09% over the course of the first 4 years of use. The output increase then reduces towards the end of this period of time, with the average monthly change falling to -0.03 ± 0.02% for the following 3 years. The output response trend was similar for all clinical energies used on the 2100C/D accelerators--6, 15 MV x-ray beams, and 4, 6, 9, 12, 16 and 20 MeV electron beams. By tracking these changes it has been possible to predict the response over time to allow appropriate adjustments in monitor chamber response to maintain a measured accelerator output within tolerance and give confidence in performance. It has also provided data to indicate the need for planned preventative intervention and indicate if the monitor chamber response is behaving as expected. (note)

  18. THE FLAG: A Web Resource of Innovative Assessment Tools for Faculty in College Science, Mathematics, Engineering, and Technology

    Science.gov (United States)

    Zeilik, M.; Mathieu, R. D.; National InstituteScience Education; College Level-One Team

    2000-12-01

    Even the most dedicated college faculty often discover that their students fail to learn what was taught in their courses and that much of what students do learn is quickly forgotten after the final exam. To help college faculty improve student learning in college Science, Mathematics, Engineering and Technology (SMET), the College Level - One Team of the National Institute for Science Education has created the "FLAG" a Field-tested Learning Assessment Guide for SMET faculty. Developed with funding from the National Science Foundation, the FLAG presents in guidebook format a diverse and robust collection of field-tested classroom assessment techniques (CATs), with supporting information on how to apply them in the classroom. Faculty can download the tools and techniques from the website, which also provides a goals clarifier, an assessment primer, a searchable database, and links to additional resources. The CATs and tools have been reviewed by an expert editorial board and the NISE team. These assessment strategies can help faculty improve the learning environments in their SMET courses especially the crucial introductory courses that most strongly shape students' college learning experiences. In addition, the FLAG includes the web-based Student Assessment of Learning Gains. The SALG offers a convenient way to evaluate the impact of your courses on students. It is based on findings that students' estimates of what they gained are more reliable and informative than their observations of what they liked about the course or teacher. It offers accurate feedback on how well the different aspects of teaching helped the students to learn. Students complete the SALG online after a generic template has been modified to fit the learning objectives and activities of your course. The results are presented to the teacher as summary statistics automatically. The FLAG can be found at the NISE "Innovations in SMET Education" website at www.wcer.wisc.edu/nise/cl1

  19. Ultraviolet-induced cutaneous hyperemia and steroid-induced cutaneous hypoemia measured by 133Xe disappearance in dogs

    International Nuclear Information System (INIS)

    Chimoskey, J.E.; Flanagan, W.

    1974-01-01

    133 Xe disappearance rates in dog skin were determined by injection of 100 μc 133 Xe dissolved in 0.025 ml physiologic saline solution into the skin with a 30-gauge needle and external detection of gamma radiation with a 2-inch sodium iodide crystal, photomultiplier, rate meter, and timer-scaler system. Skin temperature was measured by a thermistor. Skin blood flow was manipulated by the topical application of fluocinolone acetonide and by ultraviolet radiation. Fluocinolone acetonide caused significant reduction of skin blood flow, and ultraviolet irradiation caused significant increase in skin blood flow

  20. Studying the induced radioactivity of a varian clinac 2100C/D accelerator

    International Nuclear Information System (INIS)

    Lu Feng; Li Hailiang; Deng Daping; Shang Yunying; Jing Zhongjun

    2008-01-01

    Objective: To Study the influences of dose, time, distance and irradiation mode on induced radioactivity by measuring a Varian Clinac 2100C/D accelerator. Methods: The induced radioactivity was measured in different dose, time, distance and irradiation mode by using of 450P model dosemeter. The results was analysed. Results: The induced radioactivity is direct ratio with dose, inverse ratio with time and distance. In different irradiation mode, the induced radioactivity is different. Conclusion: The induced radioactivity level of accelerator is related with dose, time, distance and irradiation mode. (authors)

  1. [Regional liver circulation and the scintigraphic representation of the portal circulation with 133Xe].

    Science.gov (United States)

    Kroiss, A

    1984-01-01

    Regional hepatic blood flow has been determined by 4 methods with the aid of the 133Xe washout technique: scintisplenoportography (direct application of 133Xe into the spleen by means of a thin needle); arterial method (133Xe is injected into the A. hepatica by means of a catheter); retrograde-venous method (133Xe administered by an occluding hepatic vein catheter); percutaneous intrahepatic method (133Xe administered directly into the parenchyma by means of a Chiba needle). Ad 1.: Scintisplenoportography (SSP) was executed with 97 patients: 8 patients with a healthy liver presented a hepatic blood flow of 103.37 +/- 11.5 ml/100 g/min. 4 patients with a chronic hepatitis showed a hepatic blood flow of 105.67 +/- 10.2 ml/100 g/min. In 38 patients with compensated cirrhosis, hepatic blood flow was determined with 58.15 +/- 11.5 ml/100 g/min and 19 patients with decompensated cirrhosis showed a blood flow of 34.54 +/- 7.2 ml/100 g/min. Of the 19 patients, who did not present any liver image, 2 patients suffered from a prehepatic block, 1 patient (female) from a posthepatic block, the rest were decompensated cirrhoses. In 5 patients suffering from steatosis only collateral circulation was determined and in 4 patients the spleen could not be punctured. In the patients with compensated and decompensated cirrhosis of the liver, hepatic blood flow differentiated significantly (p less than 0.001) from patients with healthy livers and chronic hepatitis. In the patients with bioptically assured steatosis only the washout constant was determined. Reproducibility of this method was tested in 4 patients and no statistical difference of hepatic blood flow values could be found and the correlation coefficient amounted to 0.9856. The advantage of SSP lies in the possibility of recording the portal vein circulation: cranial collaterals were found in 33 patients, 2 patients had caudal collaterals exclusively and 29 patients cranial and caudal collaterals. 33 cirrhosis patients

  2. U.S. BICENTENNIAL EXPOSITION & PAINTING OF AMERICAN FLAG ON VAB

    Science.gov (United States)

    1976-01-01

    Transformation of the U. S. Bicentennial on Science and Technology from an artist's concept to reality is well underway at KSC. At lower right are stages of the Saturn V rocket which will form part of the Exposition. Four of the 15 domes erected to house exhibits by 16 federal agencies and numerous industrial firms are visible in the foreground. At left center, workmen on a scaffold can be seen completing the blue field on the American flag being painted on the Vehicle Assembly Building. The Exposition will be open to the public from May 30 through September 7.

  3. /sup 133/Xe clearance of the knee joint of patients suffering from arthritis and osteoarthrosis

    Energy Technology Data Exchange (ETDEWEB)

    Balint, G.; Reviczky, L.A.; Lendvay, J.; Boehm, U.; Kucsera, K.; Genti, Gy. (Orszagos Reuma es Fizioterapias Intezet, Budapest (Hungary))

    1982-01-01

    65 inflammed and 13 non-inflammed knee joints of patients suffering from osteoarthrosis were examined by the Xe/sup 133/ clearance method. The control group consisted of 27 patients with exsudative arthritis of the knee. The counts of 80 ..mu..C /sup 133/Xe given intraarticcularly were measured above the knee joint by NK 350 energy selective counter. The time needed to halve the count rate measured in the 4th minute after administration (biological half life (T1/2)) was significantly different in the three groups. It was the longest in the non-inflammed arthrosis, the shortest in the exsudative arthritis group. Significant differences were apparent regarding joint pain and tenderness in all the three groups. Though the synovial protein level and the C/sub 3/ complement level were significantly different, in the three groups no relationship was found between the T1/2 and synovial/serum protein ratio or between the synovial/serum C/sub 3/ ratio. The authors concluded that /sup 133/Xe clearance, which measures the perfusion of the synovial membrane, can be used for measuring the inflammatory activity of knee joint synovitis.

  4. Measurement of dynamic adsorption coefficient of Xe on coconut charcoal in CO2 streams by gas-solid chromatography

    International Nuclear Information System (INIS)

    Sun Xinxi; Huang Yuying; Li Wangchang

    1984-01-01

    This paper presents a method for measuring the dynamic adsorption coefficients of Xe on coconut charcoal II-2 in CO 2 carrier streams by SP-2305E gas chromatograph with the thermal conductivity cell. The adsorption column is made of stainless steel (diameter 4 x 240 mm) packed with 60-80 mesh coconut charcoal II-2. The CO 2 content in carrier streams is about 87%. Three groups of data of Xe dynamic adsorption coefficient were obtained at temperature 15.5 deg C, 31.5 deg C and 50.5 deg C by pulse injection respectively. Another group was obtained at temperature approx. 16 deg C by continueous injection. In addition, adsorption isotherms and adsorption isometrics were determined. In this experimental system, the adsorption heat of Xe on coconut charcoal II-2 is 2820 cal/mole

  5. Comment on 'Direct observation of the 2D3/2-2D5/2 ground-state splitting in Xe9+''

    International Nuclear Information System (INIS)

    Biedermann, C.; Radtke, R.

    2007-01-01

    We have found that xenon in different charge states, namely, Xe 9+ and Xe 31+ , can contribute to the radiation in the 598 nm spectral range. Our observation resolves the discrepancy of line identification given by Takacs et al. [Phys. Rev. A 73, 052505 (2006)] and Crespo et al. [Can. J. Phys. 80, 1687 (2002)

  6. 76 FR 1665 - Stakeholder Meetings Regarding the U.S.-Flag Great Lakes Fleet Revitalization Study; Correction

    Science.gov (United States)

    2011-01-11

    ... DEPARTMENT OF TRANSPORTATION Maritime Administration [Docket No. MARAD-2010-0111] Stakeholder Meetings Regarding the U.S.-Flag Great Lakes Fleet Revitalization Study; Correction AGENCY: Maritime Administration, Department of Transportation. ACTION: Correction Notice. SUMMARY: On December 29, 2010, at 75 FR...

  7. Measurement of Kr-85 and Xe-133 as undisturbed tracers for the representing of atmospheric transport after disposal of radioactivity from nuclear facilities; Messungen von Kr-85 und Xe-133 als ungestoerte Tracer zur Darstellung atmosphaerischer Transportvorgaenge nach Freisetzung von Radioaktivitaet aus kerntechnischen Anlagen

    Energy Technology Data Exchange (ETDEWEB)

    Frank, G.; Steinkopff, T. [Deutscher Wetterdienst (Germany); Salvamoser, J. [Institut fuer Angewandte Isotopen-, Gas- und Umweltuntersuchungen (IGU), Woerthsee (Germany)

    2016-07-01

    The Deutscher Wetterdienst (DWD, German Meteorological Service) operates since 1996 a sampling and measurement device for the radioactive rare gases Kr-85 and Xe-133 in Offenbach. These measurements are embedded in the German Measurement and Information System for Monitoring Environmental Radioactivity (Integriertes Mess- und Informationssystem zur Ueberwachung der Radioaktivitaet in der Umwelt, IMIS) [1]. In addition to these measurements the DWD is sampling rare gases in Potsdam and since 2014 in Trier in cooperation with the Bundesamt fuer Strahlenschutz (Federal Office for Radiation Protection, BfS). In the frame of the Global Atmosphere Watch (GAW)-program of the WMO the DWD operated a sampling station at the Zugspitze (Schneefernerhaus) from 1999 to 2005. This location at the Zugspitze is well suited for the observation of long distance transport of Kr-85 in the higher atmosphere. The DWD in Offenbach operates a complex analytical system for the measurement of Kr-85 and Xe-133 since 1998. This system consists of sampling with first enrichment, second enrichment, gas chromatographic separation and preparation of Krypton and Xenon and measurement of Kr-85 and Xe-133. Using the example Fukushima, it is shown, that the radioactive rare gases Kr-85 and Xe-133 are well undisturbed tracers for atmospheric transport in case of a nuclear accident or routine nuclear reprocessing plants. Measurements of Xe-133, I-131, Cs-137 and Kr-85 are correlated with source and atmospheric transport to the sampling sites at Offenbach and Potsdam.

  8. Photoionization of Xe inside C60: Atom-fullerene hybridization, giant cross-section enhancement, and correlation confinement resonances

    International Nuclear Information System (INIS)

    Madjet, Mohamed E.; Renger, Thomas; Hopper, Dale E.; McCune, Matthew A.; Chakraborty, Himadri S.; Rost, Jan-M.; Manson, Steven T.

    2010-01-01

    A theoretical study of the subshell photoionization of the Xe atom endohedrally confined in C 60 is presented. Powerful hybridization of the Xe 5s state with the bottom edge of C 60 π band is found that induces strong structures in the 5s ionization, causing the cross section to differ significantly from earlier results that omit this hybridization. The hybridization also affects the angular distribution asymmetry parameter of Xe 5p ionization near the Cooper minimum. The 5p cross section, on the other hand, is greatly enhanced by borrowing considerable oscillator strength from the C 60 giant plasmon resonance via the atom-fullerene dynamical interchannel coupling. Beyond the C 60 plasmon energy range the atomic subshell cross sections display confinement-induced oscillations in which, over the large 4d shape resonance region, the dominant 4d oscillations induce their ''clones'' in all degenerate weaker channels known as correlation confinement resonances.

  9. Temperature and energy effects on secondary electron emission from SiC ceramics induced by Xe17+ ions.

    Science.gov (United States)

    Zeng, Lixia; Zhou, Xianming; Cheng, Rui; Wang, Xing; Ren, Jieru; Lei, Yu; Ma, Lidong; Zhao, Yongtao; Zhang, Xiaoan; Xu, Zhongfeng

    2017-07-25

    Secondary electron emission yield from the surface of SiC ceramics induced by Xe 17+ ions has been measured as a function of target temperature and incident energy. In the temperature range of 463-659 K, the total yield gradually decreases with increasing target temperature. The decrease is about 57% for 3.2 MeV Xe 17+ impact, and about 62% for 4.0 MeV Xe 17+ impact, which is much larger than the decrease observed previously for ion impact at low charged states. The yield dependence on the temperature is discussed in terms of work function, because both kinetic electron emission and potential electron emission are influenced by work function. In addition, our experimental data show that the total electron yield gradually increases with the kinetic energy of projectile, when the target is at a constant temperature higher than room temperature. This result can be explained by electronic stopping power which plays an important role in kinetic electron emission.

  10. Search for the permanent electric dipole moment of {sup 129}Xe

    Energy Technology Data Exchange (ETDEWEB)

    Grasdijk, Olivier; Jungmann, Klaus; Willmann, Lorenz [KVI, University of Groningen (Netherlands); Heil, Werner; Karpuk, Sergei; Scharth, Anja; Sobolev, Yuri; Tullney, Kathlynne [Institut fuer Physik, Universitaet Mainz (Germany); Allmendinger, Fabian; Schmidt, Ulrich [Physikalisches Institut, Universitaet Heidelberg (Germany); Burghoff, Martin; Kilian, Wolfgang; Schnabel, Allard; Seifert, Frank; Trahms, Lutz [PTB Berlin (Germany)

    2013-07-01

    Permanent electric dipole moments (EDMs) violate parity and time reversal symmetry at the same time. Assuming CPT invariance a non-zero EDM would also violate CP symmetry, which could provide an explanation for the observed matter-antimatter asymmetry in the universe. An EDM at the present limit of experimental sensitivity would provide unambiguous evidence for physics beyond the Standard Model. Our approach is to observe the coherent spin-precession of co-located {sup 3}He/{sup 129}Xe polarized samples over extended periods of 1 day, typically. Based on results of measurements on Lorentz-invariance, we intend to reach a measurement sensitivity that will improve the present upper limit d{sub Xe} = 3 . 10{sup -27} ecm significantly. Phase I of this experiment will be performed in the magnetically shielded room BMSR-2 of the PTB Berlin using very sensitive SQUID gradiometers as magnetic flux detectors and electric fields of 2 kV/cm. The experimental setup, in particular the implementation of the electric field, and current status of work are presented.

  11. Flagging optically shallow pixels for improved analysis of ocean color data

    Science.gov (United States)

    McKinna, L. I. W.; Werdell, J.; Knowles, D., Jr.

    2016-02-01

    Ocean color remote-sensing is routinely used to derive marine geophysical parameters from sensor-observed water-leaving radiances. However, in clear geometrically shallow regions, traditional ocean color algorithms can be confounded by light reflected from the seafloor. Such regions are typically referred to as "optically shallow". When performing spatiotemporal analyses of ocean color datasets, optically shallow features such as coral reefs can lead to unexpected regional biases. Benthic contamination of the water-leaving radiance is dependent on bathymetry, water clarity and seafloor albedo. Thus, a prototype ocean color processing flag called OPTSHAL has been developed that takes all three variables into account. In the method described here, the optical depth of the water column at 547 nm, ζ(547), is predicted from known bathymetry and estimated inherent optical properties. If ζ(547) is less then the pre-defined threshold, a pixel is flagged as optically shallow. Radiative transfer modeling was used to identify the appropriate threshold value of ζ(547) for a generic benthic sand albedo. OPTSHAL has been evaluated within the NASA Ocean Biology Processing Group's L2GEN code. Using MODIS Aqua imagery, OPTSHAL was tested in two regions: (i) the Pedro Bank south-west of Jamaica, and (ii) the Great Barrier Reef, Australia. It is anticipated that OPTSHAL will benefit end-users when quality controlling derived ocean color products. Further, OPTSHAL may prove useful as a mechanism for switching between optically deep and shallow algorithms during ocean color processing.

  12. Charged hadron spectra and dijet $p_{\\mathrm{T}}$ correlations measured in Xe+Xe collisions at $\\sqrt{s_{_\\text{NN}}}=5.44$TeV with the ATLAS detector

    CERN Document Server

    The ATLAS collaboration

    2018-01-01

    The Large Hadron Collider recorded 3$\\mu$b${}^{-1}$ of Xe+Xe data in 2017 at a nucleon-nucleon centre-of-mass energy of $\\sqrt{s_{_\\text{NN}}} = 5.44$TeV. To probe the physics of "jet quenching" in heavy-ion collisions with nuclei lighter than lead, measurements using these data are presented, namely the transverse momentum asymmetry of dijet pairs and the rates for production of charged particles. The dijet transverse momentum imbalance is characterized by the ratio of sub-leading to leading jet transverse momenta, $x_{\\mathrm{J}} = p_{\\mathrm{T_2}}/ p_{\\mathrm{T_1}}$. Distributions of $x_{\\mathrm{J}}$ are measured using dijet pairs having $p_{\\mathrm{T_1}} > 100$GeV and are not unfolded to the particle level. A centrality-dependent modification relative to $\\sqrt{s} = 5.02$TeV $pp$ collisions is observed. It is consistent with that measured in 5.02TeV Pb+Pb collisions, either when compared in the same centrality interval, or when compared using common intervals of forward calorimeter transverse energy. Char...

  13. The 2100MHz radiofrequency radiation of a 3G-mobile phone and the DNA oxidative damage in brain.

    Science.gov (United States)

    Sahin, Duygu; Ozgur, Elcin; Guler, Goknur; Tomruk, Arın; Unlu, Ilhan; Sepici-Dinçel, Aylin; Seyhan, Nesrin

    2016-09-01

    We aimed to evaluate the effect of 2100MHz radiofrequency radiation emitted by a generator, simulating a 3G-mobile phone on the brain of rats during 10 and 40 days of exposure. The female rats were randomly divided into four groups. Group I; exposed to 3G modulated 2100MHz RFR signal for 6h/day, 5 consecutive days/wk for 2 weeks, group II; control 10 days, were kept in an inactive exposure set-up for 6h/day, 5 consecutive days/wk for 2 weeks, group III; exposed to 3G modulated 2100MHz RFR signal for 6h/day, 5 consecutive days/wk for 8 weeks and group IV; control 40 days, were kept in an inactive exposure set-up for 6h/day, 5 consecutive days/wk for 8 weeks. After the genomic DNA content of brain was extracted, oxidative DNA damage (8-hydroxy-2'deoxyguanosine, pg/mL) and malondialdehyde (MDA, nmoL/g tissue) levels were determined. Our main finding was the increased oxidative DNA damage to brain after 10 days of exposure with the decreased oxidative DNA damage following 40 days of exposure compared to their control groups. Besides decreased lipid peroxidation end product, MDA, was observed after 40 days of exposure. The measured decreased quantities of damage during the 40 days of exposure could be the means of adapted and increased DNA repair mechanisms. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Pervasive Mobile and Ambient Wireless Communications COST Action 2100

    CERN Document Server

    Zanella, Alberto

    2012-01-01

    Pervasive Mobile and Ambient Wireless Communications reports the findings of COST 2100, a project of the European intergovernmental COST framework addressing various topics currently emerging in mobile and wireless communications. Drawing on experience developed in this and earlier COST projects, the text represents the final outcome of collaborative work involving more than 500 researchers in 140 institutions and 30 countries (including outside Europe). The book’s subject matter includes: • transmission techniques; • signal processing; • radio channel modelling and measurement; • radio network issues; and • recent paradigms including ultra-wideband, cooperative, vehicle-to-vehicle and body communications. The research reported comes from a variety of backgrounds: academic, equipment-manufacturing and operational. The information contained in this book will bring the study reported to a wider audience from all those spheres of work. Pervasive Mobile and Ambient Wireless Communications will be of i...

  15. Plunger lifetime measurements in {sup 128}Xe using Coulomb excitation in inverse kinematics

    Energy Technology Data Exchange (ETDEWEB)

    Rother, Wolfram; Dewald, Alfred; Ilie, Gabriela; Pissulla, Thomas; Melon, Barbara; Jolie, Jan; Pascovici, Gheorghe; Zell, Karl-Oskar [IKP, Universitaet zu Koeln, Koeln (Germany); Julin, Rauno; Jones, Peter; Greenless, Paul; Rahkila, Panu; Scholey, Cath [JYFL, University of Jyvaeskylae, Jyvaeskylae (Finland); Harissopulos, Sotirios; Lagoyannis, Anastasios; Konstantinopoulos, T. [INP, N.C.S.R. ' ' Demokritos' ' , Athens (Greece); Grahn, Tuomas [JYFL, University of Jyvaeskylae, Jyvaeskylae (Finland)]|[Oliver Lodge Lab., University of Liverpool, Liverpool (United Kingdom); Balabanski, Dimiter [INRNE, Sofia (Bulgaria)

    2008-07-01

    We report on an experiment using Coulomb excitation in inverse kinematics in combination with the plunger technique for measuring lifetimes of excited states of the projectile. Aside from the investigation of E(2) features in {sup 128}Xe, the aim was to explore the special features of such experiments which are also suited to be used with radioactive beams. The measurement was performed at the JYFL with the Koeln coincidence plunger device and the JuroGam spectrometer using a {sup 128}Xe beam impinging on a {sup nat}Fe target at a beam energy of 525 MeV. Recoils were detected by means of 32 solar cells placed at extrem forward angles. Recoil-gated {gamma}-singles and {gamma}{gamma}-coincidences were measured at different target-degrader distances. Details of the experiment and first results are presented.

  16. Ground-state and pairing-vibrational bands with equal quadrupole collectivity in 124Xe

    Science.gov (United States)

    Radich, A. J.; Garrett, P. E.; Allmond, J. M.; Andreoiu, C.; Ball, G. C.; Bianco, L.; Bildstein, V.; Chagnon-Lessard, S.; Cross, D. S.; Demand, G. A.; Diaz Varela, A.; Dunlop, R.; Finlay, P.; Garnsworthy, A. B.; Hackman, G.; Hadinia, B.; Jigmeddorj, B.; Laffoley, A. T.; Leach, K. G.; Michetti-Wilson, J.; Orce, J. N.; Rajabali, M. M.; Rand, E. T.; Starosta, K.; Sumithrarachchi, C. S.; Svensson, C. E.; Triambak, S.; Wang, Z. M.; Wood, J. L.; Wong, J.; Williams, S. J.; Yates, S. W.

    2015-04-01

    The nuclear structure of 124Xe has been investigated via measurements of the β+/EC decay of 124Cs with the 8 π γ -ray spectrometer at the TRIUMF-ISAC facility. The data collected have enabled branching ratio measurements of weak, low-energy transitions from highly excited states, and the 2+→0+ in-band transitions have been observed. Combining these results with those from a previous Coulomb excitation study, B (E 2 ;23+→02+) =78 (13 ) W.u. and B (E 2 ;24+→03+) =53 (12 ) W.u. were determined. The 03+ state, in particular, is interpreted as the main fragment of the proton-pairing vibrational band identified in a previous 122Te (3He,n )124Xe measurement, and has quadrupole collectivity equal to, within uncertainty, that of the ground-state band.

  17. Nuclear fragmentation for Xe+Au and Xe+Ag systems at an energy of 44 A.MeV, formation and decay of hot nuclei; Etude de la fragmentation nucleaire pour les systemes XE+AU et XE+AG a 44 A.MeV, production et decroissance de noyaux chauds

    Energy Technology Data Exchange (ETDEWEB)

    Meslin, C.

    1995-01-01

    A study of the formation and the decay of hot nuclear fragments produced in the reactions Xe+Au and Xe+Ag at an energy of 44 A.MeV is presented in this thesis. The 4{pi} experimental setup consisted of four multidetectors -two for the detection of the fragments (Z>7; DELF and XYZT) and two for the detection of the charged particles (Z<6; MUR and TONNEAU) and allowed an analysis using ``complete events`` (80 % of the total charge and the total parallel linear momentum of the entrance channel) to be carried out. The reaction mechanism is binary with as observed at low energy an almost complete relaxation of the incident energy. The collision results in two hot fragments at the beginning of the exit channel which decay by evaporation and/or fragmentation. In addition of these two body events, we have identified a new dynamic mechanism where we detect a small fragment, called the neck, coming form the overlap of the nuclei during the interaction, in coincidence with a projectile-like fragment and a target-like fragment. For the most dissipative collisions, the deep inelastic collision have allowed an estimation of the lifetime of the hot nuclear fragments to be made. This is possible using proximity effects and fragment-fragment space-time correlations of the decay of one or two primary partners from the deep inelastic collisions. This method is seen to reach its limits in the case of the reactions studied here. (authors). 61 refs.

  18. Projected changes in terrestrial carbon storage in Europe under climate and land-use change, 1990-2100

    International Nuclear Information System (INIS)

    Zaehle, S.; Bondeau, A.; Cramer, W.; Erhard, M.; Sitch, S.; Smith, P.C.; Zaehle, S.; Smith, P.C.; Carter, T.R.; Erhard, M.; Prentice, C.; Prentice, C.; Reginster, I.; Rounsevell, M.D.A.; Sitch, S.; Smith, B.; Sykes, M

    2007-01-01

    Changes in climate and land use, caused by socio-economic changes, greenhouse gas emissions, agricultural policies and other factors, are known to affect both natural and managed ecosystems, and will likely impact on the European terrestrial carbon balance during the coming decades. This study presents a comprehensive European Union wide (EU15 plus Norway and Switzerland, EU*) assessment of potential future changes in terrestrial carbon storage considering these effects based on four illustrative IPCC-SRES story-lines (A1FI, A2, B1, B2). A process-based land vegetation model (LPJ-DGVM), adapted to include a generic representation of managed ecosystems, is forced with changing fields of land-use patterns from 1901 to 2100 to assess the effect of land-use and cover changes on the terrestrial carbon balance of Europe. The uncertainty in the future carbon balance associated with the choice of a climate change scenario is assessed by forcing LPJ-DGVM with output from four different climate models (GCMs: CGCM2, CSIRO2, HadCM3, PCM2) for the same SRES story-line. Decrease in agricultural areas and afforestation leads to simulated carbon sequestration for all land-use change scenarios with an average net uptake of 17-38 Tg C/year between 1990 and 2100, corresponding to 1.9-2.9% of the EU*s CO 2 emissions over the same period. Soil carbon losses resulting from climate warming reduce or even offset carbon sequestration resulting from growth enhancement induced by climate change and increasing atmospheric CO 2 concentrations in the second half of the twenty-first century. Differences in future climate change projections among GCMs are the main cause for uncertainty in the cumulative European terrestrial carbon uptake of 4.4-10.1 Pg C between 1990 and 2100. (authors)

  19. Systematics of triaxial deformation in Xe, Ba, and Ce nuclei

    International Nuclear Information System (INIS)

    Yan, J.; Vogel, O.; von Brentano, P.; Gelberg, A.

    1993-01-01

    The (β,γ) deformation parameters of even-even Xe, Ba, and Ce nuclei have been calculated by using the triaxial rotor model. Deformation parameters calculated, on one hand, from decay properties and, on the other hand, from energies are in good agreement. The smooth dependence of the deformation parameters on Z and N is discussed. The results are compared with those extracted from properties of odd-A nuclei

  20. XeCl laser treatment of polyethersulfone membrane in the air and water

    International Nuclear Information System (INIS)

    Panah, A Hashemi; Mollabashi, M; Pazokian, H; Barzin, J

    2015-01-01

    XeCl laser irradiation of Polyethersulfone membranes in air and water were done. The irradiated surface were modified chemically or morphologically depends on the laser parameters and the mediums in which irradiation is done. The results in improving the surface hydrophilicity and biocompatibility for the biological applications were compared

  1. Red flags to screen for malignancy and fracture in patients with low back pain : systematic review

    NARCIS (Netherlands)

    Downie, Aron; Williams, Christopher M.; Henschke, Nicholas; Hancock, Mark J.; Ostelo, Raymond W J G; de Vet, Henrica C W; Macaskill, Petra; Irwig, Les; van Tulder, Maurits W; Koes, Bart W; Maher, Christopher G.

    2013-01-01

    OBJECTIVE: To review the evidence on diagnostic accuracy of red flag signs and symptoms to screen for fracture or malignancy in patients presenting with low back pain to primary, secondary, or tertiary care. DESIGN: Systematic review. DATA SOURCES: Medline, OldMedline, Embase, and CINAHL from

  2. TEM study of xenon bubbles evolution in Xe-implanted Cu. Bubbles shape, epitaxial orientation and adsorption phenomenon

    International Nuclear Information System (INIS)

    Guillot, J.; Cartraud, M.; Garem, H.; Templier, C.; Desoyer, J.C.

    1987-01-01

    TEM is used to perform a study of xenon clusters changes in Xe-implanted Cu. After implantation, xenon is gathered into f.c.c. crystalline precipitates with a lattice parameter value of 0.580 nm. During annealing at 600 0 C large (110) facetted bubbles appear (2r≅35 nm) which contain fluid xenon. When cooling down to 100 K, xenon solidifies on bubbles facets in form of a thin membrane. The epitaxial orientations between solid xenon and copper are the same as adsorbed Xe on Cu(110) [fr

  3. Development of a correction factor for Xe-133 vials for use with a dose calibrator

    International Nuclear Information System (INIS)

    Gels, G.L.; Piltingsrud, H.V.

    1982-01-01

    Manufacturers of dose calibrators who give calibration settings for various radionuclies sometimes do not specify the type of radionuclide container the calibration is for. The container, moreover, may not be of the same type as those a user might purchase. When these factors are not considered, the activity administered to the patient may be significantly different from that intended. An experiment is described in which calibration factors are determined for measurement of Xe-133 activity in vials in a dose calibrator. This was accomplished by transferring the Xe-133 from the commercial vials to standard NBS calibration ampules. Based on ten such transfers, the resulting correction factor for the dose calibrator was 1.22

  4. Psychometric Analysis of the Systematic Observation of Red Flags for Autism Spectrum Disorder in Toddlers

    Science.gov (United States)

    Dow, Deanna; Guthrie, Whitney; Stronach, Sheri T.; Wetherby, Amy M.

    2017-01-01

    The purpose of this study was to examine the utility of the Systematic Observation of Red Flags as an observational level-two screening measure to detect risk for autism spectrum disorder in toddlers when used with a video-recorded administration of the Communication and Symbolic Behavior Scales. Psychometric properties of the Systematic…

  5. Analysis and characterization of heavy residues produced in 129Xe + natSn reactions between 8 and 25 AMeV

    International Nuclear Information System (INIS)

    Moisan, J.

    2008-06-01

    Studies with the INDRA multidetector of the 129 Xe + nat Sn reactions showed the unexpected existence of heavy fragments with a charge as large as Z=70. The charges of Xe and Sn are 54 and 50 respectively. Reactions between nuclei with a charge product greater than 2700 are dominated by deep inelastic collisions. For Xe + Sn the product is exactly 2700. After these observations, 129 Xe + nat Sn reactions at 8, 12, 15, 20 and 25 AMeV have been done. It will then be possible to clarify if the heavy residues are formed by an incomplete fusion, massive transfers occurring in deep inelastic collisions or a very asymmetric fission of a compound system. This work will present experimental results obtained by the analysis of these experiments. We will show that heavy residues are formed with a production cross-section of 10 -2 mb. Angular distributions show that the residues can be produced by an incomplete fusion of the projectile and the target. The study of the products in coincidence with the residues shows that a compound system was formed, followed by a fission producing the residue and a lighter fragment. The comparison with a phenomenological model, HIPSE, confirms that the model is valid at these energies

  6. Projectile-like fragments from 129Xe+natCu reactions at E/A = 40 MeV

    International Nuclear Information System (INIS)

    Russ, D.E.; Mignerey, A.C.; Garcia-Solis, E.J.

    1996-01-01

    The bombarding of heavy nuclei with energetic heavy projectiles has been one of the most important experimental tools for nuclear science. At low beam energies, (E/A) beam 100 MeV, these mean field effects are less important and nucleon-nucleon interactions dominate. Within the intermediate energy region, the situation is less clear because of both the mean field and nucleon-nucleon effects contribute. There is no consensus on the theoretical treatment of nuclear reaction in the intermediate energy regime and statistical, dynamical, and hybrid models have been used with limited success. Previous studies of 136 Xe + 209 Bi at E/A = 28 MeV carried out at Michigan State University (MSU) have been well described by a damped reaction mechanism. On the other hand, 129 Xe + nat Cu at E/A = 50 MeV also at MSU has been compared with a hybrid model with reasonable success. In order to see a transition from a damped reaction mechanism to more fragmentation-like processes, an experiment was carried out at MSU using 129 Xe beams at E/A = 30, 40, 50, and 60 MeV. The targets were Cu, Sc, and Au. The current study only looks at the projectile-like fragments (PLF) detected in the Maryland Forward Array (MFA)

  7. Validation of SCALE4.4a for Calculation of Xe-Sm Transients After a Scram of the BR2 Reactor

    International Nuclear Information System (INIS)

    Kalcheva, S.; Ponsard, B.; Koonen, E.

    2007-01-01

    The aim of this report is to validate the computational modules system SCALE4.4a for evaluation of reactivity changes, macroscopic absorption cross sections and calculations of the positions of the Control Rods during their motion in Xe-Sm transient after a scram of the BR-2 reactor. The rapid shutting down of the reactor by inserting of negative reactivity by the Control Rods is known as a reactor scram. Following reactor scram, a large xenon and samarium buildup occur in the reactor, which may appreciably affect the multiplication factor of the core due to enormous neutron absorption. The validation of the calculations of Xe-Sm transients by SCALE4.4a has been performed on the measurements of the positions of the Control Rods during their motion in Xe-Sm transients of the BR-2 reactor and on comparison with the calculations by the standard procedure XESM, developed at the BR-2 reactor. A final conclusion is made that the SCALE4.4a modules system can be used for evaluation of Xe-Sm transients of the BR-2 reactor. The utilization of the code is simple, the computational time takes from few seconds.

  8. 49 CFR 214.521 - Flagging equipment for on-track roadway maintenance machines and hi-rail vehicles.

    Science.gov (United States)

    2010-10-01

    ... maintenance machines and hi-rail vehicles. 214.521 Section 214.521 Transportation Other Regulations Relating... WORKPLACE SAFETY On-Track Roadway Maintenance Machines and Hi-Rail Vehicles § 214.521 Flagging equipment for on-track roadway maintenance machines and hi-rail vehicles. Each on-track roadway maintenance machine...

  9. 38 CFR 1.10 - Eligibility for and disposition of the United States flag for burial purposes.

    Science.gov (United States)

    2010-07-01

    ... separation from such service under conditions other than dishonorable, on or after April 25, 1951. (Authority... issued a flag on application signed by guardian). (iii) Parents, including adoptive, stepparents, and foster parents. (iv) Brothers or sisters, including brothers or sisters of the halfblood. (v) Uncles or...

  10. Observation of elastic scattering effects on photoelectron angular distributions in free Xe clusters

    International Nuclear Information System (INIS)

    Oehrwall, G; Tchaplyguine, M; Gisselbrecht, M; Lundwall, M; Feifel, R; Rander, T; Schulz, J; Marinho, R R T; Lindgren, A; Sorensen, S L; Svensson, S; Bjoerneholm, O

    2003-01-01

    We report an observation of substantial deviations in the photoelectron angular distribution for photoionization of atoms in free Xe clusters compared to the case of photoionization of free atoms. The cross section, however, seems not to vary between the cluster and free atoms. This observation was made in the vicinity of the Xe 4d Cooper minimum, where the atomic angular distribution is known to vary dramatically. The angular distribution of electrons emitted from atoms in the clusters is more isotropic than that of free atoms over the entire kinetic energy range studied. Furthermore, the angular distribution is more isotropic for atoms in the interior of the clusters than for atoms at the surface. We attribute this deviation to elastic scattering of the outgoing photoelectrons. We have investigated two average cluster sizes, ≥ 4000 and 1000 and found no significant differences between these two cases

  11. Successive composition of two laser channels upon excitation of He-Ar-Xe (2.03 μm) and Ar-Xe (1.73 μm) mixtures by uranium fission fragments

    International Nuclear Information System (INIS)

    Pikulev, A A; Tsvetkov, V M; Sosnin, P V; Sinyanskii, A A

    2009-01-01

    The operation efficiency of the scheme with successive composition of two laser channels upon excitation of the active medium by uranium-235 fission fragments is studied experimentally and numerically. For the He:Ar:Xe = 380:380:1 mixture (at a pressure of 1 atm and the lasing wavelength λ = 2.03 μm) the maximum lasing power of a double channel (1 kW) is almost twice that of a single channel (540 W). Calculations show that in the case of ideal composition (without losses on mirrors) the lasing power of the double channel can be increased to 1.2 kW. For the Ar:Xe = 380:1 mixture (the pressure is 0.5 atm, λ = 1.73 μm) the maximum lasing power of the double channel (620 W) is slightly above that of the single channel (520 W), which is caused by the losses on aluminum mirrors employed for channel doubling and by a negative effect of optical inhomogeneities. In the case of ideal composition, the lasing power can be increased to 830 W. (lasers)

  12. The decay of /sup 120/Xe

    CERN Document Server

    Münnich, F; Lode, D; Pessara, W; Schrader, H

    1974-01-01

    The decay scheme of 40 min /sup 120/Xe has been investigated using isotopically separated sources produced by the ISOLDE facility at CERN. A total number of 202 gamma -transitions has been observed in this decay; 188 of them have been placed in a level scheme involving 34 excited states in /sup 120/I. Most of these levels are based on the results of gamma - gamma coincidence experiments with two Ge(Li) detectors. Internal conversion coefficients have been obtained with a Si(Li) detector and a magnetic spectrometer. The half-life of 4 low- lying levels in /sup 120/I has been measured by delayed coincidence techniques. From these measurements, partial half-lives for some transitions have been deduced and are compared with the single- particle estimates. Two E2 transitions are strongly enhanced. (24 refs).

  13. Evolution of quadrupole and octupole collectivity north-east of $^{132}$ Sn: the even Te and Xe isotopes

    CERN Multimedia

    We propose to study excited states in isotopes north-east of the doubly-magic $^{132}$Sn by $\\gamma$-ray spectroscopy following "safe" Coulomb excitation. The experiment aims to the determine B(E2) and B(E3) values to follow the evolution of quadrupole and octupole collectivity when going away from the shell closures at Z = 50 and N = 82. The B(E2; 0$^+_{gs}$ $\\rightarrow$ 2$^+_{1}$) values in the even isotopes $^{138-144}$Xe have been measured at REX-ISOLDE and the systematic trend towards neutron-rich nuclei is well described even by an empirical Grodzins-type formula. An increasing dipole moment observed for $^{140,142}$Xe is interpreted as indirect signature of increasing octupole correlations peaking at N = 88. So far, no B(E3) values are known. In contrast to the Xe isotopes, the Te ones, in particular $^{136}$Te, are known for their notoriously irregular behaviour. In order to understand the nuclear structure also on a microscopic basis, the isotope $^{136}$Te with just one pair of protons and neutrons...

  14. Performance assessment of a new laser system for efficient spin exchange optical pumping in a spin maser measurement of 129Xe EDM

    International Nuclear Information System (INIS)

    Funayama, C.; Furukawa, T.; Sato, T.; Ichikawa, Y.; Ohtomo, Y.; Sakamoto, Y.; Kojima, S.; Suzuki, T.; Hirao, C.; Chikamori, M.; Hikota, E.; Tsuchiya, M.; Yoshimi, A.; Bidinosti, C. P.; Ino, T.; Ueno, H.; Matsuo, Y.; Fukuyama, T.; Asahi, K.

    2015-01-01

    We demonstrate spin-exchange optical pumping of 129 Xe atoms with our newly made laser system. The new laser system was prepared to provide higher laser power required for the stable operation of spin maser oscillations in the 129 Xe EDM experiment. We studied the optimum cell temperature and pumping laser power to improve the degree of 129 Xe spin polarization. The best performance was achieved at the cell temperature of 100 ∘ C with the presently available laser power of 1 W. The results show that a more intense laser is required for further improvement of the spin polarization at higher cell temperatures in our experiment

  15. Descent of line bundles to GIT quotients of flag varieties by maximal torus

    OpenAIRE

    Kumar, Shrawan

    2007-01-01

    Let L be a homogeneous ample line bundle on any flag variety G/P and let T be a maximal torus of G. We prove a general necessary and sufficient condition for L to descend as a line bundle on the GIT quotient of G/P by T. We use this result to explicitly determine exactly which L descend to the GIT quotient for any simple complex algebraic group G and any parabolic subgroup P.

  16. Cerebral blood flow (CBF) with 133Xe inhalation method

    International Nuclear Information System (INIS)

    Kusunoki, Tadaki; Masumura, Michio; Tamaki, Norihiko; Matsumoto, Satoshi; Yamashita, Hideyuki.

    1982-01-01

    The effects of CO 2 inhalation on the cerebral blood flow (CBF) were examined with 133 Xe inhalation method (Novo Inhalation Cerebrograph) on 9 normal peoples and 20 patients. Nine normal peoples were divided into 3 groups consisting of each 3 peoples, namely young age group, middle age group, and old age group. Each increased CBF (%) by CO 2 inhalation was 40 -- 44 in young age group, 36 -- 37 in middle age group, and 35 -- 36 in old age group in the blood flow of the first compartment (F 1 ), and 27 -- 28 in young age group, 30 -- 31 in middle age group and 23 -- 24 in old age group in the initial slope index (ISI). Each CO 2 reactivity factor (RF) was 5.5 -- 5.8 in young age group, 3.8 -- 4.0 in middle age group and 3.3 in old age group in F 1 , and 3.1 -- 3.2 in young age group, 2.0 -- 3.3 in middle age group, and 1.2 -- 1.3 in old age group in ISI. Twenty patients consisted of 15 patients of occlusive cerebrovascular disease, 2 patients of head injury, 2 patients of normal pressure hydrocephalus and one patient of subarachnoid hemorrhage. RF was abnormally lower than normal value in 5 patients in F 1 , but in 7 in ISI. Clinical benefits of CBF study during CO 2 inhalation with 133 Xe inhalation method were discussed. (author)

  17. Prevalence and Red Flags Regarding Specified Causes of Back Pain in Older Adults Presenting in General Practice

    NARCIS (Netherlands)

    Enthoven, Wendy T. M.; Geuze, Judith; Scheele, Jantine; Bierma-Zeinstra, Sita M. A.; Bueving, Herman J.; Bohnen, Arthur M.; Peul, Wilco C.; van Tulder, Maurits W.; Berger, Marjolein Y.; Koes, Bart W.; Luijsterburg, Pim A. J.

    BACKGROUND: In a small proportion of patients experiencing unspecified back pain a specified underlying pathology is present. OBJECTIVE: To identify the prevalence of physician-specified causes of back pain and to assess associations between red flags and vertebral fractures, as diagnosed by the

  18. Intruder states, coexistence, and approaches to deformation: The study of 120Xe and the N = 66 isotones

    International Nuclear Information System (INIS)

    Mantica, P.F. Jr.; Zimmerman, B.E.; Ford, C.E.; Walters, W.B.; Rikovska, J.; Stone, N.J.

    1989-01-01

    In this chapter, new results of γ-ray and conversion-electron spectroscopic studies of the structure of 119,121 Te and 126,127 Xe will be reported. These results will be described along with the results of previous studies of intruder structures in the Te and Xe mass region. The observed structures will be contrasted with other intruder structure identified in the Sn, Cd, and Pd isotopes. Results of IBM mixing calculations will be shown for the even-even Te nuclides. The role of intruder structures in the development of nuclear deformation will be discussed. 52 refs., 8 figs., 1 tab

  19. Cerebral blood flow studied by 133Xe inhalation technique in parkinsonism: loss of hyperfrontal pattern

    International Nuclear Information System (INIS)

    Bes, A.; Gueell, A.; Fabre, N.; Dupui, P.; Victor, G.; Geraud, G.

    1983-01-01

    Cerebral blood flow (grey matter flow) in parkinsonism requires further investigation. The noninvasive method of 133 Xe inhalation permits study of larger numbers of subjects than previously used invasive techniques such as the intracarotid 133 Xe injection method. Measurements were made in this laboratory in 30 subjects having Parkinson's disease. Mean hemispheric blood flow (F1) values were 70.4 +/- 9.3 ml/100 g/min, compared to 76.3 for a group of age-matched normal subjects, which is a decrease of -7.8%. The most striking difference was the loss of the hyperfrontal distribution in parkinsonism. The prefrontal F1 values were only 1.8% greater than the hemisphere grey matter flow, compared with 8.5% in controls of a similar age group

  20. Flag varieties, toric varieties, and suspensions: Three instances of infinite transitivity

    International Nuclear Information System (INIS)

    Arzhantsev, Ivan V; Zaidenberg, M G; Kuyumzhiyan, Karine G

    2012-01-01

    We say that a group G acts infinitely transitively on a set X if for every m element of N the induced diagonal action of G is transitive on the cartesian mth power X m backslash Δ with the diagonals removed. We describe three classes of affine algebraic varieties such that their automorphism groups act infinitely transitively on their smooth loci. The first class consists of normal affine cones over flag varieties, the second of nondegenerate affine toric varieties, and the third of iterated suspensions over affine varieties with infinitely transitive automorphism groups. Bibliography: 42 titles.