WorldWideScience

Sample records for fixed-angle plate osteosynthesis

  1. Fixed-angle plates in patella fractures - a pilot cadaver study

    Directory of Open Access Journals (Sweden)

    Wild M

    2011-01-01

    Full Text Available Abstract Objective Modified anterior tension wiring with K-wires and cannulated lag screws with anterior tension wiring are currently the fixation of choice for patellar fractures. Failure of fixation, migration of the wires, postoperative pain and resulting revision surgery, however, are not uncommon. After preliminary biomechanical testing of a new fixed-angle plate system especially designed for fixation of patella fractures the aim of this study was to evaluate the surgical and anatomical feasibility of implanting such a plate-device at the human patella. Methods In six fresh unfixed female cadavers without history of previous fractures around the knee (average age 88.8 years a bilateral fixed-angle plate fixation of the patella was carried out after previous placement of a transverse central osteotomy. Operative time, intra-operative problems, degree of retropatellar arthritis (following Outerbridge, quality of reduction and existence of any intraarticular screw placement have been raised. In addition, lateral and anteroposterior radiographs of all specimens were made. Results Due to the high average age of 88.8 years no patella showed an unimpaired retropatellar articular surface and all were severely osteoporotic, which made a secure fixation of the reduction forceps during surgery difficult. The operation time averaged 49 minutes (range: 36-65. Although in postoperative X-rays the fracture gap between the fragments was still visible, the analysis of the retropatellar surface showed no residual articular step or dehiscence > 0.5 mm. Also in a total of 24 inserted screws not one intraarticular malposition was found. No intraoperative complications were noticed. Conclusions Osteosynthesis of a medial third patella fracture with a bilateral fixed-angle plate-device is surgically and anatomically feasible without difficulties. Further studies have to depict whether the bilateral fixed-angle plate-osteosynthesis of the patella displays

  2. [Conventional plate osteosynthesis].

    Science.gov (United States)

    Klaue, K

    2010-02-01

    Consolidation of bone is an essential clinical problem when treating fractures, fixing osteotomies and fusing joints. In most cases, the means of fixation are plates and screws. The goal is functional postoperative therapy by moving the adjacent joints and thus avoiding the deleterious disadvantages of long-lasting articular immobilization. Pre-operative planning, surgical approach, a good understanding of the precise mechanics of the structure and the biological answer for the various tissues are prerequisites of successful osteosynthesis. The choice of implants and the application of their versatility, as well as their adaptation to individual cases are the key to good results.

  3. Dynamic plate osteosynthesis for fracture stabilization: how to do it

    Directory of Open Access Journals (Sweden)

    Juerg Sonderegger

    2010-01-01

    Full Text Available Plate osteosynthesis is one treatment option for the stabilization of long bones. It is widely accepted to achieve bone healing with a dynamic and biological fixation where the perfusion of the bone is left intact and micromotion at the fracture gap is allowed. The indications for a dynamic plate osteosynthesis include distal tibial and femoral fractures, some midshaft fractures, and adolescent tibial and femoral fractures with not fully closed growth plates. Although many lower limb shaft fractures are managed successfully with intramedullary nails, there are some important advantages of open-reduction-and-plate fixation: the risk of malalignment, anterior knee pain, or nonunion seems to be lower. The surgeon performing a plate osteosynthesis has the possibility to influence fixation strength and micromotion at the fracture gap. Long plates and oblique screws at the plate ends increase fixation strength. However, the number of screws does influence stiffness and stability. Lag screws and screws close to the fracture site reduce micromotion dramatically. Dynamic plate osteosynthesis can be achieved by applying some simple rules: long plates with only a few screws should be used. Oblique screws at the plate ends increase the pullout strength. Two or three holes at the fracture site should be omitted. Lag screws, especially through the plate, must be avoided whenever possible. Compression is not required. Locking plates are recommended only in fractures close to the joint. When respecting these basic concepts, dynamic plate osteosynthesis is a safe procedure with a high healing and a low complication rate. 

  4. Minimally invasive plating osteosynthesis for mid-distal third humeral shaft fractures.

    Science.gov (United States)

    Lian, Kejian; Wang, Lei; Lin, Dasheng; Chen, Zhiwen

    2013-08-01

    Mid-distal third humeral shaft fractures can be effectively treated with minimally invasive plating osteosynthesis and intramedullary nailing (IMN). However, these 2 treatments have not been adequately compared. Forty-seven patients (47 fractures) with mid-distal third humeral shaft fractures were randomly allocated to undergo either minimally invasive plating osteosynthesis (n=24) or IMN (n=23). The 2 groups were similar in terms of fracture patterns, fracture location, age, and associated injuries. Intraoperative measurements included blood loss and operative time. Clinical outcome measurements included fracture healing, radial nerve recovery, and elbow and shoulder discomfort. Radiographic measurements included fracture alignment, time to healing, delayed union, and nonunion. Functional outcome was satisfactory in both groups. Mean American Shoulder and Elbow Surgeons score and Mayo score were both better for the minimally invasive plating osteosynthesis group than for the IMN group (98.2 vs 97.6, respectively, and 93.5 vs 94.1, respectively; Pshaft fractures. Minimally invasive plating osteosynthesis is more suitable for complex fractures, especially for radial protection and motion recovery of adjacent joints, compared with IMN for simple fractures. Copyright 2013, SLACK Incorporated.

  5. A biomechanical comparison of four fixed-angle dorsal plates in a finite element model of dorsally-unstable radius fracture.

    Science.gov (United States)

    Knežević, Josip; Kodvanj, Janoš; Čukelj, Fabijan; Pamuković, Frane; Pavić, Arsen

    2017-11-01

    To compare the finite element models of two different composite radius fracture patterns, reduced and stabilised with four different fixed-angle dorsal plates during axial, dorsal and volar loading conditions. Eight different plastic models representing four AO/ASIF type 23-A3 distal radius fractures and four AO/ASIF 23-C2 distal radius fractures were obtained and fixed each with 1 of 4 methods: a standard dorsal non-anatomical fixed angle T-plate (3.5mm Dorsal T-plate, Synthes), anatomical fixed-angle double plates (2.4mm LCP Dorsal Distal Radius, Synthes), anatomical fixed angle T-plate (2.4mm Acu-Loc Dorsal Plate, Acumed) or anatomical variable-angle dorsal T-plate (3.5mm, Dorsal Plate, Zrinski). Composite radius with plate and screws were scanned with a 3D optical scanner and later processed in Abaqus Software to generate the finite element model. All models were axially loaded at 3 points (centrally, volarly and dorsally) with 50 N forces to avoid the appearance of plastic deformations of the models. Total displacements at the end of the bone and the stresses in the bones and plates were determined and compared. Maximal von Mises stress in bone for 3-part fracture models was very similar to that in 2-part fracture models. The biggest difference between models and the largest displacements were seen during volar loading. The stresses in all models were the highest above the fracture gap. The best performance in all parameters tested was with the Zrinski plate and the most modest results were with the Synthes T-plate. There was no significant difference between 2-part (AO/ASIF type 23-A3) and 3-part (AO/ASIF 23-C2) fracture models. Maximal stresses in the plates appeared above the fracture gap; therefore, it is worth considering the development of plates without screw holes above the gap. © 2017 Elsevier Ltd. All rights reserved.

  6. Benefits and harms of locking plate osteosynthesis in intraarticular (OTA Type C) fractures of the proximal humerus: A systematic review

    DEFF Research Database (Denmark)

    Brorson, Stig; Rasmussen, Jeppe Vejlgaard; Frich, Lars Henrik

    2012-01-01

    stable plates in AO/OTA Type C fractures of the proximal humerus. METHODS: We conducted an iterative search in PubMed, Embase, Cochrane Library, Web of Science, Cinahl, and PEDro in all languages from 1999 to November 2010. Eligible studies should study the outcome for Type C fractures after primary...... according to study type and synthesised qualitatively. No randomised clinical trials were identified. Two comparative, observational studies reported a mean CS of 71 (relative to contralateral shoulder) and 75 (non-adjusted Constant Score) for Type C fractures. For all studies mean non-adjusted CS ranged......INTRODUCTION: Locking plate osteosynthesis of proximal humeral fractures are widely recommended and used, even in complex intraarticular fracture patterns such as AO/OTA Type C fractures. We systematically reviewed clinical studies assessing the benefits and harms of osteosynthesis with angle...

  7. Stabilization of Olecranon Fractures by Tension Band Wiring or Plate Osteosynthesis: A Retrospective Study of 41 Cases.

    Science.gov (United States)

    Fournet, Alexandre; Boursier, Jean-François; Corbeau, Solène; Decambron, Adeline; Viateau, Véronique; Fayolle, Pascal; Bedu, Anne-Sophie; Leperlier, Dimitri; Manassero, Mathieu

    2018-01-01

     This article aimed to describe olecranon fracture in dogs and cats and their stabilization with tension band wiring or plate osteosynthesis, and to evaluate complications associated with each technique.  Medical records of cats and dogs that had been surgically treated for olecranon fractures with either tension band wiring or plate osteosynthesis were retrospectively reviewed. The surgical technique, complications and long-term outcomes were assessed.  Forty-one olecranon fractures were included. Fractures were articular, comminuted and open in 90, 31 and 27% of cases, respectively. Tension band wiring and plate osteosynthesis were performed in 22 and 19 fractures, respectively. Complications occurred more commonly after tension band wiring (74%) compared with plate osteosynthesis (27%) ( p  = 0.002) and these were probably related to it being used in comminuted fractures ( p  = 0.01) or to errors in technique. Minor complications included Kirschner wires migration ( n  = 5), pain ( n  = 3), osteomyelitis ( n  = 3), skin breakdown ( n  = 3) and seroma ( n  = 1). Implant failure requiring further fixation ( n  = 4) was observed only in the tension band wiring group. Other major complications included skin wound debridement and closure ( n  = 1) and chronic lameness requiring implant removal ( n  = 7). Long-term functional outcomes were excellent regardless of the technique used.  Plate osteosynthesis should be performed for olecranon fracture repair if technically feasible. Schattauer GmbH Stuttgart.

  8. A Novel Biodegradable Polycaprolactone Fixator for Osteosynthesis Surgery of Rib Fracture: In Vitro and in Vivo Study

    Directory of Open Access Journals (Sweden)

    Yi-Hsun Yu

    2015-11-01

    Full Text Available Osteosynthesis surgery for rib fractures is controversial and challenging. This study developed a noval poly(ε-caprolactone (PCL-based biodegradable “cable-tie” fixator for osteosynthesis surgery for rib fractures. A biodegradable fixator specifically for fractured ribs was designed and fabricated by a micro-injection molding machine in our laboratory. The fixator has three belts that could be passed through matching holes individually. The locking mechanism allows the belt movement to move in only one direction. To examine the in vitro biomechanical performance, ribs 3–7 from four fresh New Zealand rabbits were employed. The load to failure and stress-strain curve was compared in the three-point bending test among native ribs, titanium plate-fixed ribs, and PCL fixator-fixed ribs. In the in vivo animal study, the sixth ribs of New Zealand rabbits were osteotomized and osteosynthesis surgery was performed using the PCL fixator. Outcomes were assessed by monthly X-ray examinations, a final micro-computed tomography (CT scan, and histological analysis. The experimental results suggested that the ribs fixed with the PCL fixator were significantly less stiff than those fixed with titanium plates (p < 0.05. All ribs fixed with the PCL fixators exhibited union. The bridging callus was confirmed by gross, radiographic micro-three-dimensional (3D CT, and histological examinations. In addition, there was no significant inflammatory response of the osteotomized ribs or the PCL-rib interface during application. The novel PCL fixator developed in this work achieves satisfactory results in osteosynthesis surgery for rib fractures, and may provide potential applications in other orthopedic surgeries.

  9. [Osteosynthesis and cup revision in periprosthetic acetabulum fractures using a Kocher-Langenbeck approach].

    Science.gov (United States)

    Schwabe, P; Märdian, S; Perka, C; Schaser, K-D

    2016-04-01

    Reconstruction/stable fixation of the acetabular columns to create an adequate periacetabular requirement for the implantation of a revision cup. Displaced/nondisplaced fractures with involvement of the posterior column. Resulting instability of the cup in an adequate bone stock situation. Periprosthetic acetabulum fractures with inadequate bone stock. Extended periacetabular defects with loss of anchorage options. Isolated periprosthetic fractures of the anterior column. Septic loosening. Dorsal approach. Dislocation of hip. Mechanical testing of inlaying acetabular cup. With unstable cup situation explantation of the cup, fracture fixation of acetabulum with dorsal double plate osteosynthesis along the posterior column. Cup revision. Hip joint reposition. Early mobilization; partial weight bearing for 12 weeks. Thrombosis prophylaxis. Clinical and radiological follow-ups. Periprosthetic acetabular fracture in 17 patients with 9 fractures after primary total hip replacement (THR), 8 after revision THR. Fractures: 12 due to trauma, 5 spontaneously; 7 anterior column fractures, 5 transverse fractures, 4 posterior column fractures, 1 two column fracture after hemiendoprosthesis. 5 type 1 fractures and 12 type 2 fractures. Operatively treated cases (10/17) received 3 reinforcement ring, 2 pedestal cup, 1 standard revision cup, cup-1 cage construct, 1 ventral plate osteosynthesis, 1 dorsal plate osteosynthesis, and 1 dorsal plate osteosynthesis plus cup revision (10-month Harris Hip Score 78 points). Radiological follow-up for 10 patients: consolidation of fractures without dislocation and a fixed acetabular cup. No revision surgeries during follow-up; 2 hip dislocations, 1 transient sciatic nerve palsy.

  10. Risk of symptomatic heterotopic ossification following plate osteosynthesis in multiple trauma patients: an analysis in a level-1 trauma centre

    Directory of Open Access Journals (Sweden)

    Pape Hans-Christoph

    2009-10-01

    Full Text Available Abstract Background Symptomatic heterotopic ossification (HO in multiple trauma patients may lead to follow up surgery, furthermore the long-term outcome can be restricted. Knowledge of the effect of surgical treatment on formation of symptomatic heterotopic ossification in polytrauma is sparse. Therefore, we test the effects of surgical treatment (plate osteosynthesis or intramedullary nailing on the formation of heterotopic ossification in the multiple trauma patient. Methods We retrospectively analysed prospectively documented data of blunt multiple trauma patients with long bone fractures which were treated at our level-1 trauma centre between 1997 and 2005. Patients were distributed to 2 groups: Patients treated by intramedullary nails (group IMN or plate osteosynthesis (group PLATE were compared. The expression and extension of symptomatic heterotopic ossifications on 3-6 months follow-up x-rays in antero-posterior (ap and lateral views were classified radiologically and the maximum expansion was measured in millimeter (mm. Additionally, ventilation time, prophylactic medication like indomethacine and incidence and correlation of head injuries were analysed. Results 101 patients were included in our study, 79 men and 22 women. The fractures were treated by intramedullary nails (group IMN n = 50 or plate osteosynthesis (group PLATE n = 51. Significantly higher radiologic ossification classes were detected in group PLATE (2.9 ± 1.3 as compared to IMN (2.2 ± 1.1; p = 0.013. HO size in mm ap and lateral showed a tendency towards larger HOs in the PLATE group. Additionally PLATE group showed a higher rate of articular fractures (63% vs. 28% in IMN while IMN demonstrated a higher rate of diaphyseal fractures (72% vs. 37% in PLATE; p = 0.003. Ventilation time, indomethacine and incidence of head injuries showed no significant difference between groups. Conclusion Fracture care with plate osteosynthesis in polytrauma patients is associated with

  11. MINIMAL INVASIVE PLATE OSTEOSYNTHESIS- AN EFFECTIVE TREATMENT METHOD FOR DISTAL TIBIA INTRAARTICULAR (PILON FRACTURES- AN 18 MONTHS FOLLOW UP

    Directory of Open Access Journals (Sweden)

    Saket Jati

    2016-12-01

    Full Text Available BACKGROUND Tibial pilon fracture though requires operative treatment is difficult to manage. Conventional osteosynthesis is not suitable, because distal tibia is subcutaneous bone with poor vascularity. Closed reduction and Minimally Invasive Plate Osteosynthesis (MIPO for distal tibia has emerged as an alternative treatment option because it respects fracture biology and haematoma and also provides biomechanically stable construct. The aim of the study is to evaluate the results of minimally invasive plate osteosynthesis using locking plates in treating tibial pilon fractures in terms of fracture union, restoration of ankle function and complications. MATERIALS AND METHODS 30 patients with closed tibial pilon fractures (Ruedi and Allgower type I (14, type II (13, type III (3 treated with MIPO with Locking Compression Plates (LCP were prospectively followed for average duration of 18 months. RESULTS Average duration of injury-hospital and injury-surgery interval was as 12.05 hrs. and 3.50 days, respectively. All fractures got united with an average duration of 20.8 weeks (range 14-28 weeks. Olerud and Molander score was used for evaluation at 3 months, 6 months and 18 months. One patient had union with valgus angulation of 15 degrees, but no nonunion was found. CONCLUSION The present study shows that MIPO with LCP is an effective treatment method in terms of union time and complications rate for tibial pilon fracture promoting early union and early weight bearing.

  12. A novel combined method of osteosynthesis in treatment of tibial fractures: a comparative study on sheep with application of rod-through-plate fixator and bone plating.

    Science.gov (United States)

    Tralman, G; Andrianov, V; Arend, A; Männik, P; Kibur, R T; Nõupuu, K; Uksov, D; Aunapuu, M

    2013-04-01

    The study compares the efficiency of a new bone fixator combining periostal and intramedullary osteosynthesis to bone plating in treatment of tibial fractures in sheep. Experimental osteotomies were performed in the middle third of the left tibia. Animals were divided into two groups: in one group (four animals) combined osteosynthesis (rod-through-plate fixator, RTP fixator) was applied, and in the other group (three animals) bone plating was used. The experiments lasted for 10 weeks during which fracture union was followed by radiography, and the healing process was studied by blood serum markers reflecting bone turnover and by histological and immunohistochemical investigations. In the RTP fixator group, animals started to load body weight on the operated limbs the next day after the surgery, while in the bone plating group, this happened only on the seventh day. In the RTP fixator group, consolidation of fractures was also faster, as demonstrated by radiographical, histological, and immunohistochemical investigations and in part by blood serum markers for bone formation. It can be concluded that application of RTP fixation is more efficient than plate fixation in the treatment of experimental osteotomies of long bones in sheep. © 2012 Blackwell Verlag GmbH.

  13. A prospective randomized study of operative treatment for noncomminuted humeral shaft fractures: conventional open plating versus minimal invasive plate osteosynthesis.

    Science.gov (United States)

    Kim, Ji Wan; Oh, Chang-Wug; Byun, Young-Soo; Kim, Jung Jae; Park, Ki Chul

    2015-04-01

    To compare the clinical and radiologic results of conventional open plating (COP) and minimally invasive plate osteosynthesis (MIPO) in the treatment of noncomminuted humeral shaft fractures. Randomized prospective study. Five level 1 trauma centers. Sixty-eight consecutive patients were randomized into 2 study groups: those treated by COP (COP group; n = 32) and those treated by MIPO (MIPO group; n = 36). Simple humeral shaft fractures (AO/OTA classification types A and B) were reduced by open reduction or closed reduction and fixed with a narrow 4.5/5.0 locking compression plate, metaphyseal locking compression plate, or proximal humeral internal locking system plate to the anterior lateral aspect of the humerus. Fracture healing time, operative time, radiation exposure time, and intraoperative nerve injury. To assess shoulder and elbow function, we used the University of California, Los Angeles (UCLA) scoring system and the Mayo elbow performance index, including the range of motion and pain. Radiographic measurements included fracture alignment, delayed union, and nonunion. Thirty-one fractures (97%) healed in the COP group within 16 weeks, whereas 36 fractures (100%) were healed in the MIPO group by 15 weeks. No significant difference was observed in the operative time or complication rates. In both groups, all fractures achieved union without malunion and with excellent functional outcomes by definition of the Mayo elbow performance index and UCLA scoring system. This study confirmed a high overall rate of union and excellent functional outcomes in both MIPO and COP groups. MIPO is equivalent to COP as a safe and effective method for simple types of humeral shaft fractures when surgery is indicated, and the surgeon is experienced in the technique. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

  14. Minimally invasive plate osteosynthesis for humerus diaphyseal fractures

    Directory of Open Access Journals (Sweden)

    M Shantharam Shetty

    2011-01-01

    Full Text Available Background: Minimally invasive plate osteosynthesis (MIPO technique is reported as a satisfactory procedure for the treatment of humeral shaft fractures by the anterior approach by several authors. However, none of the published reports had a significant follow-up nor have they reported patient outcomes. We evaluated the clinical, radiographic, and functional outcome over a minimum follow-up of 2 years using the same MIPO technique to humeral shaft fracture. Materials and Methods: 32 adult patients with diaphyseal fractures of the humerus treated with MIPO between June 2007 and October 2008 were included in the study. Patients with metabolic bone disease, polytrauma, and Gustilo and Anderson type 3 open fractures with injury severity score >16 were excluded from the study. All cases were treated with closed indirect reduction and locking plate fixation using the MIPO technique. The surgery time, radiation exposure, and time for union was noted. The shoulder and elbow function was assessed using the UCLA shoulder and Mayo elbow performance scores, respectively. Results: Of the 32 patients in the study, 19 were males and 13 were females. The mean age was 39 years (range: 22-70 years. Twenty-seven of the thirty-two patients (84.3% had the dominant side fractured. We had eight cases of C2 type; five cases of C1 and A2 type; four cases of B2 type; three cases each of B3, B1, and A1 type; and one case of A3 type of fracture. The mean surgical time was 91.5 minutes (range: 70-120 minutes and mean radiation exposure was 160.3 seconds (range: 100-220 seconds. The mean radiological fracture union time was 12.9 weeks (range: 10-20 weeks. Shoulder function was excellent in 27 cases (84.3% and good in remaining 5 cases (15.6% on the UCLA score. Elbow function was excellent in 26 cases (81.2%, good in 5 cases (15.6%, and fair in 1 case (3.1% who had an associated olecranon fracture that was fixed by tension band wire in the same sitting. Conclusion: MIPO of

  15. Masticatory System Biomechanical Photoelastic Simulation fot the Comparision of the Conventional and Uni-Lock Systems in Mandibular Osteosynthesis

    Directory of Open Access Journals (Sweden)

    Jose Luis Cebrian Carretero

    2017-08-01

    Full Text Available The biomechanical consequences of the interaction between titanium trauma plates and screws and the fractured mandible are still a matter of investigation. The mathematical and biomechanical models that have been developed show limitations and the experimental studies are not able to reproduce muscle forces and internal stress distributions in the bone-implant interface and mandibular structure. In the present article we show a static simulator of the masticatory system to demonstrate in epoxy resin mandibular models, by means of 3D (three-dimensional photoelasticity, the stress distribution using different osteosynthesis methods in the mandibular angle fractures. The results showed that the simulator and 3D photoelasticity were a useful method to study interactions between bone and osteosynthesis materials. The “Lock” systems can be considered the most favourable method due to their stress distribution in the epoxy resin mandible. 3D photoelasticity in epoxy resin models is a useful method to evaluate stress distribution for biomechanical studies. Regarding to mandibular osteosynthesis, “lock” plates offer the most favourable stress distribution due to being less aggressive to the bone

  16. Treatment of Middle Third Humeral Shaft Fractures with Anteromedial Plate Osteosynthesis through an Anterolateral Approach.

    Science.gov (United States)

    Kumar, B S; Soraganvi, P; Satyarup, D

    2016-03-01

    Background: Treatment of humeral shaft fractures has been a subject of debate for many decades. Even though a large majority of humeral shaft fractures can be treated by non operative methods, few conditions like open fractures, polytrauma, ipsilateral humeral shaft and forearm fractures require surgical intervention. The goal of treatment of humeral shaft fractures is to establish union with an acceptable humeral alignment and to restore the patient to pre-injury level of function. The objective was to assess the incidence of radial nerve palsy, non-union and mean time required for in anteromedial plate osteosynthesis with anterolateral approach and also to measure the functional outcome of this procedure. Method: A prospective study was conducted in the Department of Orthopaedics, PESIMSR, Kuppam, Andhra Pradesh, from August 2012 to August 2015 with a total of 54 patients who were operated with anteromedial plate osteosynthesis were included in the study. Rodriguez- Merchan criteria was used to grade the functional outcome. Results: Of the 54 patients, 28 (58.85%) were in the age group of 30-40 years. The most common fracture pattern identified was A3 type (48.14%).The mean (± SD) duration of surgery for anteromedial humeral plating was 53 ± 5.00 minutes. The time taken for the fracture to unite was less than 16 weeks in the majority or 50 patients (92.59%). Four (7.40%) patients had delayed union. There was no incidence of iatrogenic radial nerve palsy. Rodriguez - Merchan criteria showed that 37(68.51%) of the patients had good and 12 (22.22%) had excellent functional outcome.

  17. Treatment of type 2 and 4 olecranon fractures with locking compression plate osteosynthesis in horses: a prospective study (2002-2008).

    Science.gov (United States)

    Jackson, M; Kummer, M; Auer, J; Hagen, R; Fuerst, A

    2011-01-01

    This prospective study describes a series of 18 olecranon fractures in 16 horses that were treated with locking compression plates (LCP). Twelve of the 18 fractures were simple (type 2), whereas six were comminuted (type 4). Six fractures were open and 12 were closed. Each horse underwent LCP osteosynthesis consisting of open reduction and application of one or two LCP. Complete fracture healing was achieved in 13 horses. Three horses had to be euthanatized: two because of severe infection and one because of a comminuted radial fracture 11 days after fixation of the olecranon fracture. Complications encountered after discharge of the horses from the Equine Hospital at the Vetsuisse Faculty (University of Zurich) included implant infection (n=2) and lameness (n=3), which were successfully treated with implant removal. Despite being easier to use, LCP osteosynthesis resulted in a clinical outcome similar to DCP osteosynthesis.

  18. A comparative study of intramedullary interlocking nailing and minimally invasive plate osteosynthesis in extra articular distal tibial fractures.

    Science.gov (United States)

    Daolagupu, Arup K; Mudgal, Ashwani; Agarwala, Vikash; Dutta, Kaushik K

    2017-01-01

    Extraarticular distal tibial fractures are among the most challenging fractures encountered by an orthopedician for treatment because of its subcutaneous location, poor blood supply and decreased muscular cover anteriorly, complications such as delayed union, nonunion, wound infection, and wound dehiscence are often seen as a great challenge to the surgeon. Minimally invasive plate osteosynthesis (MIPO) and intramedullary interlocking nail (IMLN) are two well-accepted and effective methods, but each has been historically related to complications. This study compares clinical and radiological outcome in extraarticular distal tibia fractures treated by intramedullary interlocking nail (IMLN) and minimally invasive plate osteosynthesis (MIPO). 42 patients included in this study, 21 underwent IMLN and 21 were treated with MIPO who met the inclusion criteria and operated between June 2014 and May 2015. Patients were followed up for clinical and radiological evaluation. In IMLN group, average union time was 18.26 weeks compared to 21.70 weeks in plating group which was significant ( P ankle stiffness, and infection, were seen in interlocking group as compared to plating group. Average functional outcome according to American Orthopedic Foot and Ankle Society score was measured which came out to be 96.67. IMLN group was associated with lesser duration of surgery, earlier weight bearing and union rate, lesser incidence of infection and implant irritation which makes it a preferable choice for fixation of extra-articular distal tibial fractures. However, larger randomized controlled trials are required for confirming the results.

  19. [Locked plating with minimally invasive percutaneous plate osteosynthesis versus intramedullary nailing of distal extra-articular tibial fracture: a retrospective study].

    Science.gov (United States)

    Yao, Qi; Ni, Jie; Peng, Li-bin; Yu, Da-xin; Yuan, Xiao-ming

    2013-12-17

    To compare the efficacies of minimally invasive plate osteosynthesis (MIPPO) and interlocking intramedullary nailing (IMN) in the treatment of extra-articular fractures of distal tibia. Retrospective reviews were conducted for 126 patients with extra-articular distal tibia fractures. Treatment was either MIPPO (n = 61) or IMN (n = 65). The outcomes were assessed by comparing operating duration, time to union, the last follow-up American Orthopedic Foot and Ankle Society (AOFAS) score and complication rate. The average follow-up period was 23.7 (12-53) months. In the minimally invasive plate osteosynthesis group, there were deep infections (n = 2), superficial infections (n = 5), delayed union (n = 2), malunion (n = 2) and knee joint pain (n = 10) were observed. In addition, the average operating duration (85.9 ± 18.9 min), average time to union (17.3 ± 3.8 weeks) and average AOFAS (83.2 ± 11.9) were analyzed. In the interlocking intramedullary nailing group, there were delayed union (n = 3), malunion (n = 12) and knee joint pain (n = 22). And the average operating duration (83.3 ± 15.7 min), average time to union (16.5 ± 3.1 weeks) and average AOFAS (84.9 ± 12.0) were analyzed. No statistical significance existed in operating duration, time to union and the last follow-up AOFAS between two groups (P > 0.05). However, the rates of malformation and knee joint pain were higher in the intramedullary nail group than those in the plate group. And the difference was statistically significant (P = 0.015, P = 0.025). Both MIPPO and IMN are effective for extra-articular fractures of distal tibia. However, the former has the advantage of lowers rate of malformation and knee joint pain. Therefore a surgeon should consider the degree of injury while managing extra-articular fracture of distal tibia.

  20. Treatment of Middle Third Humeral Shaft Fractures with Anteromedial Plate Osteosynthesis through an Anterolateral Approach

    Directory of Open Access Journals (Sweden)

    Kumar BS

    2016-03-01

    Full Text Available Background: Treatment of humeral shaft fractures has been a subject of debate for many decades. Even though a large majority of humeral shaft fractures can be treated by non operative methods, few conditions like open fractures, polytrauma, ipsilateral humeral shaft and forearm fractures require surgical intervention. The goal of treatment of humeral shaft fractures is to establish union with an acceptable humeral alignment and to restore the patient to pre-injury level of function. The objective was to assess the incidence of radial nerve palsy, non-union and mean time required for in anteromedial plate osteosynthesis with anterolateral approach and also to measure the functional outcome of this procedure. Method: A prospective study was conducted in the Department of Orthopaedics, PESIMSR, Kuppam, Andhra Pradesh, from August 2012 to August 2015 with a total of 54 patients who were operated with anteromedial plate osteosynthesis were included in the study. RodriguezMerchan criteria was used to grade the functional outcome. Results: Of the 54 patients, 28 (58.85% were in the age group of 30-40 years. The most common fracture pattern identified was A3 type (48.14%.The mean (+ SD duration of surgery for anteromedial humeral plating was 53 ± 5.00 minutes. The time taken for the fracture to unite was less than 16 weeks in the majority or 50 patients (92.59%. Four (7.40% patients had delayed union. There was no incidence of iatrogenic radial nerve palsy. Rodriguez – Merchan criteria showed that 37(68.51% of the patients had good and 12 (22.22% had excellent functional outcome.

  1. Surgical treatment of sagittal fracture of mandibular condyle using long-screw osteosynthesis.

    Science.gov (United States)

    Luo, Shufang; Li, Bo; Long, Xing; Deng, Mohong; Cai, Hengxing; Cheng, Yong

    2011-07-01

    The retrospective study evaluated long-screw (bicortical screw) osteosynthesis used in the surgical treatment of sagittal fracture of the mandibular condyle and compared it with titanium plates and removal of the condylar fragment. Ninety-five patients with sagittal fracture of the mandibular condyle received open surgical treatment from 1997 to 2008. Among these patients, the condylar fragments were fixed with long screws in 56 cases (group A), were fixed with titanium plates in 12 cases (group B), and were completely removed in 24 cases (group C). Follow-up was carried out clinically and radiologically. The clinical features included limitation of mandibular mobility, occlusion disturbance, lateral deviation on mouth opening, joint pain, clicking, facial asymmetry, and patient's subjective evaluation. The radiologic parameters consisted of degree of bony resorption, bony change, change of osteosynthesis material, and shortening of mandibular ramus height. Anatomic reduction and functional restoration were obtained and no severe complication was detected in group A. However, 3 of 14 patients had severe osteoarthrosis and 2 of 14 patients had ankylosis in group B. In group C 3 of 24 patients had mandibular retrusion, 4 of 24 patients had front teeth open bite, 4 of 24 patients had severe osteoarthrosis, and 1 of 24 patients had ankylosis. The long-screw fixation group had a more favorable prognosis than the titanium plate group and the group in which removal of the condylar fragment was performed. The long-screw fixation technique might be suitable for use in the surgical treatment of sagittal fractures of the mandibular condyle. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  2. The Role of Minimally Invasive Plate Osteosynthesis in Rib Fixation: A Review

    Directory of Open Access Journals (Sweden)

    Michael Bemelman

    2016-02-01

    Full Text Available More than a century ago, the first scientific report was published about fracture fixation with plates. During the 1950’s, open reduction and plate fixation for fractures were standardized by the founders of Arbeitsgemeinschaft für osteosynthesefragen/Association for the Study of Internal Fixation. Since the introduction of plate fixation for fractures, several plates and screws have been developed, all with their own characteristics. To accomplice more fracture stability, it was thought the bigger the plate, the better. The counter side was a compromised blood supply of the bone, often resulting in bone necrosis and ultimately delayed or non-union. With the search and development of new materials and techniques for fracture fixation, less invasive procedures have become increasingly popular. This resulted in the minimally invasive plate osteosynthesis (MIPO technique for fracture fixation. With the MIPO technique, procedures could be performed with smaller incisions and thus with less soft tissue damage and a better preserved blood supply. The last 5 years rib fixation has become increasingly popular, rising evidence has becomeavailable suggesting that surgical rib fixation improves outcome of patients with a flail chest or isolated rib fractures. Many surgical approaches for rib fixation have been described in the old literature, however, most of these techniques are obscure nowadays. Currently mostly large incisions with considerable surgical insult are used to stabilize rib fractures. We think that MIPO deserves a place in the surgical treatment of rib fractures. We present the aspects of diagnosis, preoperative planning and operative techniques in regard to MIPO rib fixation.

  3. The Role of Minimally Invasive Plate Osteosynthesis in Rib Fixation: A Review

    Science.gov (United States)

    Bemelman, Michael; van Baal, Mark; Yuan, Jian Zhang; Leenen, Luke

    2016-01-01

    More than a century ago, the first scientific report was published about fracture fixation with plates. During the 1950’s, open reduction and plate fixation for fractures were standardized by the founders of Arbeitsgemeinschaft für osteosynthesefragen/Association for the Study of Internal Fixation. Since the introduction of plate fixation for fractures, several plates and screws have been developed, all with their own characteristics. To accomplice more fracture stability, it was thought the bigger the plate, the better. The counter side was a compromised blood supply of the bone, often resulting in bone necrosis and ultimately delayed or non-union. With the search and development of new materials and techniques for fracture fixation, less invasive procedures have become increasingly popular. This resulted in the minimally invasive plate osteosynthesis (MIPO) technique for fracture fixation. With the MIPO technique, procedures could be performed with smaller incisions and thus with less soft tissue damage and a better preserved blood supply. The last 5 years rib fixation has become increasingly popular, rising evidence has become available suggesting that surgical rib fixation improves outcome of patients with a flail chest or isolated rib fractures. Many surgical approaches for rib fixation have been described in the old literature, however, most of these techniques are obscure nowadays. Currently mostly large incisions with considerable surgical insult are used to stabilize rib fractures. We think that MIPO deserves a place in the surgical treatment of rib fractures. We present the aspects of diagnosis, preoperative planning and operative techniques in regard to MIPO rib fixation. PMID:26889439

  4. Less invasive plate osteosynthesis in humeral shaft fractures.

    Science.gov (United States)

    Apivatthakakul, Theerachai; Phornphutkul, Chanakarn; Laohapoonrungsee, Anupong; Sirirungruangsarn, Yuddhasert

    2009-12-01

    conventional screws in each fragment. Between January 2003 and January 2006, 23 patients were operated on using the less invasive plate osteosynthesis technique. The minimum follow-up period of 12 months was completed in 20 patients. The mean healing time was 14.6 weeks, defined as three of four cortices having stable bridging callus. In one patient with delayed union, healing was observed after 28 weeks. Functional outcomes were evaluated using the Constant Score and the Hospital for Special Surgery (HSS) Score. 19 patients had good to excellent elbow function with a mean HSS Score of 93.5 points. All patients achieved satisfactory shoulder function with a mean Constant Score of 85.8 points compared to 90.6 on the healthy side. Complications observed were one paresthesia of lateral cutaneous nerve of forearm (no radial nerve injury) and one loosening of the LCP (Locking Compression Plate) screws due to technical error.

  5. Osteosynthesis with plate of under contact (LC DCP) in long bones

    International Nuclear Information System (INIS)

    Suarez Romero, Fabio; Bocanegra Navia, Sergio; Nino C, Jose Maria; Tapias Urrego Alexander

    2002-01-01

    In this study 98 patients were evaluated to who are carried out osteosynthesis with plates of under contact in the hospital military of Bogota, between January of 1996 and January of the 2002, with diagnostic of open fractures, fracture closed and pseudoarthrosis that committed the humerus, the cube and the radius, the metacarpal, the femur and the tibia. Of the total, 67,3% corresponded to open fractures and 32,7% they were closed fractures; as for its origin, 54,1% was hurt by firearm, 28,6% for accident rail car and 17,3% for direct trauma. The segment more affected it was the forearm with 43 cases. In the open fractures the cultivation was positive in 11,2%. The average of surgical washed was of 3,2. 110 plates were placed in 98 patients. In 58% one carries out boarding of the fracture focus, and in 41,8% limited boarding. The pursuit average was of 28,2 months. It was not any difference statistically significant between the boarding type and the time of consolidation. It doesn't present osteomyelitis neither septic loosening in the patient's treaties

  6. Technical Errors May Affect Accuracy of Torque Limiter in Locking Plate Osteosynthesis.

    Science.gov (United States)

    Savin, David D; Lee, Simon; Bohnenkamp, Frank C; Pastor, Andrew; Garapati, Rajeev; Goldberg, Benjamin A

    2016-01-01

    In locking plate osteosynthesis, proper surgical technique is crucial in reducing potential pitfalls, and use of a torque limiter makes it possible to control insertion torque. We conducted a study of the ways in which different techniques can alter the accuracy of torque limiters. We tested 22 torque limiters (1.5 Nm) for accuracy using hand and power tools under different rotational scenarios: hand power at low and high velocity and drill power at low and high velocity. We recorded the maximum torque reached after each torque-limiting event. Use of torque limiters under hand power at low velocity and high velocity resulted in significantly (P torque and subsequent complications. For torque limiters, the most reliable technique involves hand power at slow velocity or drill power with careful control of insertion speed until 1 torque-limiting event occurs.

  7. High failure rate of trochanteric fracture osteosynthesis with proximal femoral locking compression plate.

    Science.gov (United States)

    Wirtz, C; Abbassi, F; Evangelopoulos, D S; Kohl, S; Siebenrock, K A; Krüger, A

    2013-06-01

    Stable reconstruction of proximal femoral (PF) fractures is especially challenging due to the peculiarity of the injury patterns and the high load-bearing requirement. Since its introduction in 2007, the PF-locking compression plate (LCP) 4.5/5.0 has improved osteosynthesis for intertrochanteric and subtrochanteric fractures of the femur. This study reports our early results with this implant. Between January 2008 and June 2010, 19 of 52 patients (12 males, 7 females; mean age 59 years, range 19-96 years) presenting with fractures of the trochanteric region were treated at the authors' level 1 trauma centre with open reduction and internal fixation using PF-LCP. Postoperatively, partial weight bearing was allowed for all 19 patients. Follow-up included a thorough clinical and radiological evaluation at 1.5, 3, 6, 12, 24, 36 and 48 months. Failure analysis was based on conventional radiological and clinical assessment regarding the type of fracture, postoperative repositioning, secondary fracture dislocation in relation to the fracture constellation and postoperative clinical function (Merle d'Aubigné score). In 18 patients surgery achieved adequate reduction and stable fixation without intra-operative complications. In one patient an ad latus displacement was observed on postoperative X-rays. At the third month follow-up four patients presented with secondary varus collapse and at the sixth month follow-up two patients had 'cut-outs' of the proximal fragment, with one patient having implant failure due to a broken proximal screw. Revision surgeries were performed in eight patients, one patient receiving a change of one screw, three patients undergoing reosteosynthesis with implantation of a condylar plate and one patient undergoing hardware removal with secondary implantation of a total hip prosthesis. Eight patients suffered from persistent trochanteric pain and three patients underwent hardware removal. Early results for PF-LCP osteosynthesis show major

  8. Locking compression plate osteosynthesis of complicated mandibular fractures in six horses.

    Science.gov (United States)

    Kuemmerle, J M; Kummer, M; Auer, J A; Nitzl, D; Fürst, A E

    2009-01-01

    Complicated mandibular fractures were recognised in one foal, one pony and four horses. The foal was two months old while the adult animals ranged in age from 12 to 24 years. Three horses had a unilateral horizontal ramus fracture. Two fractures were open and one was closed. Comminution was present in one of these patients while the other two horses had marked displacement of the fragments. Two suffered from comminuted fractures of the horizontal and vertical ramus of the mandible. One of these patients had open and infected fractures. One foal had a bilateral horizontal ramus fracture with marked periosteal 'new bone' formation and malalignement which required corrective osteotomy. Each horse underwent locking compression plate (LCP) osteosynthesis consisting of open fracture reduction and application of one to three 4.5/5.0 mm LCP at the ventral, lateral or caudal aspect of the mandible under fluoroscopic control. Two 3.5 mm LCP were used in the foal. Plate fixation was supported by application of a cerclage wire construct between the incisor and premolar teeth in most patients. Complete fracture healing, with an excellent functional and cosmetic outcome, was achieved in all of the patients. Complications encountered included seroma formation, screw and wire breakage, as well as implant and apical tooth root infections. The LCP was removed after fracture healing had occurred in four patients.

  9. The potential influence of subduction zone polarity on overriding plate deformation, trench migration and slab dip angle

    NARCIS (Netherlands)

    Schellart, W. P.

    2007-01-01

    A geodynamic model exists, the westward lithospheric drift model, in which the variety of overriding plate deformation, trench migration and slab dip angles is explained by the polarity of subduction zones. The model predicts overriding plate extension, a fixed trench and a steep slab dip for

  10. Unstable recent intracapsular femoral neck fractures in young adults: Osteosynthesis and primary valgus osteotomy using broad dynamic compression plate

    Directory of Open Access Journals (Sweden)

    Singh M

    2008-01-01

    Full Text Available Background: Displaced intracapsular femoral neck fractures continue to be a difficult problem to treat. Various treatment modalities and their modifications have been proposed to improve the outcome. Osteosynthesis and primary valgus angulation osteotomy is one of them. Technique and outcome in a consecutive series of recent intracapsular femoral neck fractures in young adults, from a single center, is presented. Materials and Methods: Fifty-five patients of recent (< 3 weeks old displaced intracapsular fracture neck femur (Garden III and IV, Pauwels III, with or without comminution in the age group 20-50 years (mean 35.4±10.4 years were subjected to osteosynthesis and primary valgus intertrochanteric osteotomy using contoured broad dynamic compression plate (DCP. The patients were followed up from two to six years (mean 4.6 years. Results: Fifty-one fractures united by six months of the index procedure (92.7% union range. Avascular necrosis (AVN developed in six patients (11%. The other complications were shortening (six, coxa vara (two, infection (two and delayed union at osteotomy site (one. Excellent results were achieved in 48, good/fair in four and poor in three patients. Conclusion: Osteosynthesis with cancellous screw and primary valgus intertrochanteric osteotomy stabilized by a contoured broad DCP is a simple, easy to perform, biological treatment. Failure in a particular case can be treated with any appropriate second procedure. Level of Evidence: IV

  11. Numerical analysis of standard and modified osteosynthesis in long bone fractures treatment.

    Science.gov (United States)

    Sisljagić, Vladimir; Jovanović, Savo; Mrcela, Tomislav; Radić, Radivoje; Selthofer, Robert; Mrcela, Milanka

    2010-03-01

    The fundamental problem in osteoporotic fracture treatment is significant decrease in bone mass and bone tissue density resulting in decreased firmness and elasticity of osteoporotic bone. Application of standard implants and standard surgical techniques in osteoporotic bone fracture treatment makes it almost impossible to achieve stable osteosynthesis sufficient for early mobility, verticalization and load. Taking into account the form and the size of the contact surface as well as distribution of forces between the osteosynthetic materials and the bone tissue numerical analysis showed advantages of modified osteosynthesis with bone cement filling in the screw bed. The applied numerical model consisted of three sub-models: 3D model from solid elements, 3D cross section of the contact between the plate and the bone and the part of 3D cross section of the screw head and body. We have reached the conclusion that modified osteosynthesis with bone cement resulted in weaker strain in the part of the plate above the fracture fissure, more even strain on the screws, plate and bone, more even strain distribution along all the screws' bodies, significantly greater strain in the part of the screw head opposite to the fracture fissure, firm connection of the screw head and neck and the plate hole with the whole plate and more even bone strain around the screw.

  12. Stability of midface fracture repair using absorbable plate and screw system pilot holes drilled and pin placement at angles other than 90°.

    Science.gov (United States)

    Carron, Michael A; Zuliani, Giancarlo; Pereira, Lucio; Abuhamdan, Maher; Thibault, Adrianna; Dau, Nathan; Bir, Cynthia

    2014-01-01

    Conventional plating systems use titanium plates for fixation of fractures, with benefits of strength and biocompatibility. However, titanium plates require that screws be placed at a 90° angle to the pilot holes. In the midface, this becomes extremely difficult. Today, a variety of craniomaxillofacial osteosynthesis systems are available, including resorbable plating systems. Specifically, the KLS Martin Sonic Weld system ultrasonically fuses the plate and the head of the pin when placed and will fill the pilot hole grooves completely even at less than 90° angles, which provides a tremendous advantage in midface fracture repair. To determine if the KLS Martin Sonic Weld system provides plate-screw construct stability in human heads even when placed at acute angles at the midface buttresses. DESIGN, SETTING, AND SPECIMENS: Twenty cadaveric head specimens with the mandible removed were prepared by creating osteotomies in the midface buttresses bilaterally. Specimens were defleshed and placed in a 2-part testing rig to hold and position the head for testing in a standard material testing system. Testing was performed at the Wayne State University Bioengineering test laboratories, Detroit, Michigan, using an Instron device and high-speed camera. Specimens were plated on one side of the midface using the KLS Martin Sonic Weld system with pilot holes and pins placed at 90° angles. On the contralateral side, the buttresses were plated with the KLS Martin Sonic Weld system at 60°, 45°, and 30° angles. Data were collected using the TDAS data acquisition system and were compared with matched pairs within each specimen. Ultrasonically vibrated pins placed into absorbable mini-plates at less than 90° angles with the KLS Martin Sonic Weld system were compared with the same amount of stress as the system placed at a 90° angle before demonstrating plate-screw construct failure. RESULTS Fifty-seven paired tests were collected, with 114 total tests. Twenty failures were

  13. [Curative efficacies of mini-invasive percutaneous osteosynthesis versus supercutaneous plating for distal tibial fractures].

    Science.gov (United States)

    He, Xianfeng; Zhu, Limei; Zhang, Jingwei; Li, Ming; Yu, Yihui

    2014-12-30

    To compare the clinical efficacies of mini-invasive percutaneous osteosynthesis (MIPO) versus supercutaneous plating with closed reduction in the treatment of distal tibial fractures. A total of 48 patients with close distal tibial fractures were treated between January 2010 and January 2012. The MIPO group included 16 males and 8 females with an average age of 36 years. And the types were A (n = 15), B (n = 6) and C (n = 3) according to the classification scheme of Association for the Study of Internal Fixation (AO/ASIF). The supercutaneous plating group also included 16 males and 8 females with an average age of 37 years. And the types were A (n = 15), B (n = 6) and C (n = 3). And the operative duration, hospital stay, union time, postoperative complications and function of ankle were compared between two groups. The mean follow-up period was 18.5 (12-26) months. There was no instance of nonunion, hardware breakdown or deep infection. Patients in supercutaneous plating group had significantly shorter mean operative duration, hospital stay and union time. Three patients and 1 patient in MIPO group presented with superficial infection and delayed union respectively while there was no occurrence in supercutaneous plating group. And the differences were not statistically significant. Fifteen patients (62.5%) complained of implant impingement or discomfort. And stripping occurred at an incidence of 15.6% during the removal time of locking screws in MIPO group. While in supercutaneous plating group, there as no complaint of skin irritation and removal of supercutaneous plate was easily performed without anesthesia. The mean AOFAS score was 90.7 ± 3.8 in supercutaneous plating group versus 88.9 ± 4.1 in MIPO group (P = 0.070). Distal tibia fractures may be treated successfully with MIPO or supercutaneous plating. However, supercutaneous plating offers multiple advantages in terms of mean operative duration, hospital stay, union time, skin irritation and implant

  14. Clinic research on the treatment for humeral shaft fracture with minimal invasive plate osteosynthesis: a retrospective study of 128 cases.

    Science.gov (United States)

    Chen, H; Hu, X; Yang, G; Xiang, M

    2017-04-01

    Minimal invasive plate osteosynthesis (MIPO) is one of the most important techniques in the treatment for humeral shaft fractures. This study was performed to evaluate the efficacy of MIPO technique for the treatment for humeral shaft fractures. We retrospectively evaluated 128 cases with humeral shaft fractures that were treated with MIPO technique from March 2005 to August 2008. All the patients were followed up by routine radiological imaging and clinical examinations. Constant-Murley score and HSS elbow joint score were used to evaluate the treatment outcome. The average duration of the surgery was 60 min (range 40-95 min) without blood transfusion. All fractures healed without infection. All cases recovered carrying angle except four cases with 10°-15° cubitus varus. After the average follow-up of 23 (13-38) months, satisfactory function was achieved according to Constant-Murley score and HSS elbow joint score. Constant-Murley score was 80 on average (range 68-91). According to HSS elbow joint score, there were 123 cases of excellent clinical outcome and five cases of effective outcome. It seems to be a safe and effective method for managing humeral shaft fractures with MIPO technique.

  15. Locking internal fixator with minimally invasive plate osteosynthesis for the proximal and distal tibial fractures

    Directory of Open Access Journals (Sweden)

    TONG Da-ke

    2012-02-01

    Full Text Available 【Abstract】Objective: To investigate the efficacy of the locking internal fixator (LIF, which includes the locking compression plate (LCP and the less invasive stable system (LISS, in the proximal and distal tibial fractures. Methods: We did a retrospective study on a total of 98 patients with either proximal or distal tibial fractures from January 2003 to January 2007, who had received the opera- tion with LIF by the minimally invasive plate osteosynthesis (MIPO technique. The data consisted of 43 proximal tibial fractures (type AO41C3 and 55 distal tibial fractures (type AO43C3. Results: No complications were observed in all patients after operation. The mean healing time was 8.4 months (range 5-14 months. Only two cases of delayed union occurred at postoperative 10 months. No infections were reported after the definitive surgery even in the cases of open fractures. All patients reached a full range of motion at postoperative 6 to 9 months and regained the normal functions of knee and ankle joints. Conclusion: Using LIF in MIPO technique is a reliable approach towards the proximal and distal tibial fractures that are not suitable for intramedullary nailing. Key words: Internal fixator; Tibial fractures; Fracture fixation, intramedullary; Bone plates

  16. OSTEOSYNTHESIS OF THE METACARPAL BONE WITH BIOABSORBABLE MATERIALS: A CASE REPORTS

    Directory of Open Access Journals (Sweden)

    Ernest Novak

    2004-04-01

    Full Text Available Background. Recent advances in biomaterial technology make it possible to produce easy-to-handle implants for osteosynthesis with ultra-high strenght and excellent biocompatibility. Biomechanical studies have shown that fixation rigidity achieved with self-reinforced (SR pins, screws and miniplates is comparable with that of metallic fixation methods. Internal fixation by means of bioabsorbable plates, screws, and pins can be used to stabilize some fractures of small bones in the hand.We report our experience with three cases where internal fixation with a SR (poly-L/DL-lactide 70/30; SR-P (L/DL LA 70/30, BioSorbTMFX miniplates and screws was carried out for stabilization of a metacarpal shaft fracture and thumb replantation.Conclusions. After bone healing is complete, metallic osteosynthesis devices become unnecessary or can even be harmful. Metallic implant-related long-term complications and secondary removal operation are avoided by using of bioabsorbable osteosynthesis devices for metacarpal bones osteosynthesis.

  17. Minimally invasive plate osteosynthesis for humeral shaft fractures: are results reproducible?

    Science.gov (United States)

    Concha, Juan M; Sandoval, Alejandro; Streubel, Philipp N

    2010-12-01

    Minimally invasive plate osteosynthesis (MIPO) has been advocated as a safe approach to humeral shaft fracture management. We evaluated the reproducibility of this technique in a regional hospital. Thirty-five patients underwent MIPO of humerus shaft fractures. Fifteen patients had an open fracture, six a preoperative radial nerve palsy, and nine a concomitant thoracic, musculoskeletal or vascular injury. At an average 12-month follow-up, 91% of fractures healed after a mean of 12 weeks (range, 8-16). Two infections occurred. Final alignment averaged 4° of varus (range, 5° of valgus to 20° of varus). Active elbow ROM averaged 114° (range, 60-135°) and was less than 100° in nine elbows. Five of six preoperative radial nerve injuries recovered spontaneously. Healing and infection rates in this study are consistent with those reported in the literature. Lower elbow ROM and higher fracture angulation at healing were nevertheless found. MIPO is technically demanding and requires adequate intraoperative imaging and surgical experience in order to obtain adequate fracture alignment. Brachialis muscle scarring and inadequate postoperative rehabilitation may be involved in limited elbow range of motion.

  18. Treatment of type 2 and 4 olecranon fractures with locking compression plate (LCP) osteosynthesis in horses: a prospective study (2002-2008)

    OpenAIRE

    Jackson, M; Kummer, M; Auer, J; Hagen, R; Fürst, A

    2011-01-01

    This prospective study describes a series of 18 olecranon fractures in 16 horses that were treated with locking compression plates (LCP). Twelve of the 18 fractures were simple (type 2), whereas six were comminuted (type 4). Six fractures were open and 12 were closed. Each horse underwent LCP osteosynthesis consisting of open reduction and application of one or two LCP. Complete fracture healing was achieved in 13 horses. Three horses had to be euthanatized: two because of severe infection an...

  19. Biomechanical study: resistance comparison of posterior antiglide plate and lateral plate on synthetic bone models simulating Danis-Weber B malleolar fractures

    Directory of Open Access Journals (Sweden)

    Bruna Buscharino

    2013-06-01

    Full Text Available OBJECTIVE : The purpose of this study was to compare different positions of plates in lateral malleolar Danis-Weber B fractures on synthetic bone: a lateral plate and a posterior antiglide plate. METHODS : Short oblique fractures of distal fibula at the level of the syndesmosys were simulated with a fibular osteotomy in sixteen synthetic fibula bones (Synbone®. Eight fractures were fixed with lateral plating associated with an independent lag screw, and the other eight were fixed with posterior antiglide plating with a lag screw through the plate. A strain gage was installed at the center of each plate at the osteotomy site. Supination and external rotation forces were applied to each of the two groups at the bend. RESULTS : The lateral position plate group suffered more deformity in response to supination forces compared to the group with the posterior antiglide plate, but this result was not statistically significant. In the tests with external rotation forces, the posterior antiglide plating group had significantly higher resistance (p < 0.05. CONCLUSION : When subjected to external rotation forces, osteosynthesis with posterior antiglide plate models simulating type B fractures of the lateral malleolus of the ankle is more resistant than that of the neutralization plate.

  20. Wire fixation osteosynthesis for the emergency treatment of patients with mandible fractures: A report of three cases

    Directory of Open Access Journals (Sweden)

    Juan Francisco Oré Acevedo

    2017-06-01

    Full Text Available Introduction: Currently, titanium plates and screws are the gold standard osteosynthesis treatment of facial bone fractures. Techniques considerer obsoletes like surgical wires osteosynthesis are not used anymore, but it is necessary to bear in mind the possibility of using wire for the treatment of cases in emergency, and in which we do not have immediately available sterile implants such as plates and screws. Objectives: Describe the mandibular osteosynthesis with surgical wire as an acceptable surgical treatment when plates and screws are not avaliable. Description: Three cases of patients with mandible fractures were presented, treated on emergency with wire. Two cases were the gunshot injuries and the remaining one suffered a recreational accident. Which required immediate treatment due to the magnitude of the damage, bone exposure and persistence of active bleeding. Conclusions: The use of surgical wire for the treatment of mandibular fractures should not be ignored and is a good alternative for situations where titanium plates and screws are not available due to economic reasons or access. The surgical outcome is stable and allows restoring partially mandibular anatomy and function looking forward a future reconstruction.

  1. Evaluation of locked plate in the osteosynthesis of fractures in osteoporotic bones.

    Science.gov (United States)

    Oboirien, Muhammad; Agbo, Stephen Patrick; Ajiboye, Lukman Olalekan

    2017-01-01

    The use of conventional dynamic compression plates (DCPs) in osteoporotic bones is associated with higher chances of implant failure. The advent and use of locking combi-plates have ensured a stable construct during osteosynthesis of fractures in osteoporotic bones. The study aims to assess the outcome of use of locking combi-plates in the management of fractures in osteoporotic bones in our environment. Cases of patients with nonunion and localized osteoporosis from January 2014 to December 2014 that were managed with locked combi-plates were reviewed. Outcome was assessed by time to healing, stability of implant construct after 6 and 12 months. There were 10 patients with mean age of 47.4 ± 12.63 years. There were 9 males and 1 female, and road traffic crashes were the mechanism of injury in 90% (n = 9) and gunshot injuries in 10% (n = 1). Atrophic nonunion was the most common indication for osteosynthesis with 80%, followed by fibrous nonunion with 10.0%. The humerus was the most common long bone involved with 50%. Locked broad DCP was used in 62.5%, and the duration between initial injury and surgery was 6 and 48 months, with an average of 17.5 months. The outcome was such that 90% healed after 12 months on follow-up while one case had the implant backing out and delay union at 6 months. The use of locked plate in the management of nonunion in the presence of osteoporosis ensures stable fixation construct and healing. Contexte: L'utilisation de plaques de compression dynamiques conventionnelles dans les os ostéoporotiques est associée à des chances plus élevées de défaillance de l'implant. L'avènement et l'utilisation de combi-plaques de verrouillage ont assuré une construction stable lors de l'ostéosyntheis de fractures dans les os ostéoporotiques. Objectifs: L'étude vise à évaluer le résultat de l'utilisation de combi-plaques de verrouillage dans la gestion des fractures dans les os ostéoporotiques dans notre environnement. Méthodologie: Les

  2. [Measurement of screw length through drilling technique in osteosynthesis of the proximal humerus fractures].

    Science.gov (United States)

    Avcı, Cem Coşkun; Gülabi, Deniz; Sağlam, Necdet; Kurtulmuş, Tuhan; Saka, Gürsel

    2013-01-01

    This study aims to investigate the efficacy of screw length measurement through drilling technique on the reduction of intraarticular screw penetration and fluoroscopy time in osteosynthesis of proximal humerus fractures. Between January 2008 and June 2012, 98 patients (34 males, 64 females; mean age 64.4 years; range 35 to 81 years) who underwent osteosynthesis using locking anatomical proximal humerus plates (PHILOS) in our clinic with the diagnosis of Neer type 2, 3 or 4 were included. Two different surgical techniques were used to measure proximal screw length in the plate and patients were divided into two groups based on the technique used. In group 1, screw length was determined by a 3 mm blunt tipped Kirschner wire without fluoroscopic control. In group 2, bilateral fluoroscopic images for each screw at least were obtained. Intraarticular screw penetration was detected in five patients (10.6%) in group 1, and in 19 patients (37.3%) in group 2. The mean fluoroscopic imaging time was 10.6 seconds in group 1 and 24.8 seconds in group 2, indicating a statistically significant difference. Screw length measurement through the drilling technique significantly reduces the intraarticular screw penetration and fluoroscopy time in osteosynthesis of proximal humerus fractures using PHILOS plates.

  3. Indirect reduction technique using a distraction support in minimally invasive percutaneous plate osteosynthesis of tibial shaft fractures.

    Science.gov (United States)

    Dong, Wen-Wei; Shi, Zeng-Yuan; Liu, Zheng-Xin; Mao, Hai-Jiao

    2016-12-01

    To describe an indirect reduction technique during minimally invasive percutaneous plate osteosynthesis (MIPPO) of tibial shaft fractures with the use of a distraction support. Between March 2011 and October 2014, 52 patients with a mean age of 48 years (16-72 years) sustaining tibial shaft fractures were included. All the patients underwent MIPPO for the fractures using a distraction support prior to insertion of the plate. Fracture angular deformity was assessed by goni- ometer measurement on preoperative and postoperative images. Preoperative radiographs revealed a mean of 7.6°(1.2°-28°) angulation in coronal plane and a mean of 6.8°(0.5°-19°) angulation in sagittal plane. Postoperative anteroposterior and lateral radio- graphs showed a mean of 0.8°(0°-4.0°) and 0.6°(0°-3.6°) of varus/valgus and apex anterior/posterior angulation, respectively. No intraoperative or postoperative complications were noted. This study suggests that the distraction support during MIPPO of tibial shaft fractures is an effective and safe method with no associated complications.

  4. Minimally-invasive plate osteosynthesis in distal tibial fractures: Results and complications.

    Science.gov (United States)

    Vidović, Dinko; Matejčić, Aljoša; Ivica, Mihovil; Jurišić, Darko; Elabjer, Esmat; Bakota, Bore

    2015-11-01

    Distal tibial or pilon fractures are usually the result of combined compressive and shear forces, and may result in instability of the metaphysis, with or without articular depression, and injury to the soft tissue. The complexity of injury, lack of muscle cover and poor vascularity make these fractures difficult to treat. Surgical treatment of distal tibial fractures includes several options: external fixation, IM nailing, ORIF and minimally-invasive plate osteosynthesis (MIPO). Management of distal tibial fractures with MIPO enables preservation of soft tissue and remaining blood supply. This is a report of a series of prospectively studied closed distal tibial and pilon fractures treated with MIPO. A total of 21 patients with closed distal tibial or pilon fractures were enrolled in the study between March 2008 and November 2013 and completed follow-up. Demographic characteristics, mechanism of injury, time required for union, ankle range of motion and complications were recorded. Fractures were classified according to the AO/OTA classification. Nineteen patients were initially managed with an ankle-spanning external fixator. When the status of the soft tissue had improved and swelling had subsided enough, a definitive internal fixation with MIPO was performed. Patients were invited for follow-up examinations at 3 and 6 weeks and then at intervals of 6 to 8 weeks until 12 months. Mean age of the patients was 40.1 years (range 19-67 years). Eighteen cases were the result of high-energy trauma and three were the result of low-energy trauma. According to the AO/OTA classification there were extraarticular and intraarticular fractures, but only simple articular patterns without depression or comminution. The average time for fracture union was 19.7 weeks (range 12-38 weeks). Mean range of motion was 10° of dorsiflexion (range 5-15°) and 28.3° of plantar flexion (range 20-35°). Three cases were metalwork-related complications. Two patients underwent plate removal

  5. MINIMUM INCISION PERCUTANEOUS PLATE OSTEOSYNTHESIS FOR DISTAL FIBULAR FRACTURES: A PROSPECTIVE STUDY

    Directory of Open Access Journals (Sweden)

    Ramkumar Reddy

    2015-09-01

    Full Text Available Distal fibular fractures are usually communitted and most of the times osteoporotic especially if they are occurring in females and in geriatric age group. These fractures are usu ally associated with other fractures, which necessitates them to be fixed accurately. Owing to the fact that distal fragment is subcutaneous with scanty soft tissue over bone, which pose these fracture fixations become difficult by open methods in view of wound healing. A prospective study of 26 patients with distal fibular fractures were treated with MIPPO with hook plate were healed with less complications and better outcome. With this background we suggest a minimally invasive incision over proximal frag ment where sufficient soft tissue cover is present. From there pushing the special hook plate subperiosteally to distal fragment, hooking the tip of fibula and fixing the proximal fragment after reduction gives a simple and effective stable fixation

  6. Fixing a fractured arthrodesed hip with rapid prototype templating and minimal invasive plate osteosynthesis

    Directory of Open Access Journals (Sweden)

    Christian Fang

    2015-12-01

    Full Text Available CASE:: We present an elderly lady with an intertrochanteric fracture of a previously fused hip. A 3D printed model of her pelvis and femur was used for implant templating before surgery. Minimal invasive fixation was performed with a spanning reversed distal femur locking plate without the need for removal of the previous implant. Multiple long locking screws were placed in the supra-acetabular region. The patient had union in 4 months, return to function and no complication. Conclusion:: The technique allowed us to optimize implant selection and insert screws safely at difficult trajectories using minimal invasive surgery. Keywords: Hip fusion, Fracture, Plating, Minimal invasive, 3D printing

  7. A STUDY OF SURGICAL MANAGEMENT OF DISTAL FEMORAL FRACTURES BY DISTAL FEMORAL LOCKING COMPRESSION PLATE OSTEOSYNTHESIS

    Directory of Open Access Journals (Sweden)

    Dema Rajaiah

    2016-08-01

    Full Text Available AIMS AND OBJECTIVES To study the fractures of distal end of femur and the mechanism of injury in distal end femur fractures, the advantages and disadvantages of open reduction and internal fixation of distal end femur fractures by distal femoral locking compression plate osteosynthesis and to analyse the outcome in terms of range of Knee motion, time to union, and limb shortening. RESULTS The mean age of patient is 44 years, 85% are males, road traffic accidents account for majority (80%, right side involved in 70%, Muller’s type C fracture is common, good range of movements is seen 90% of cases and union occurred in 95% in 5 months. The results were assessed using Neer’s score, seven (35% patients had excellent results, eight (40% patients had good results, four (20% patients had fair results and one (5% patient had poor result. CONCLUSION From our study, we conclude that DF-LCP is a safe and reliable implant and has shown excellent to satisfactory results in majority of intra-articular fractures (AO type C. Fixation with locking compression plate showed more effectiveness in severely osteoporotic bones, shorter operative stay, faster recovery, faster union rates and excellent functional outcome.

  8. HEEL BONE RECONSTRUCTIVE OSTEOSYNTHESIS

    Directory of Open Access Journals (Sweden)

    A. N. Svetashov

    2010-01-01

    Full Text Available To detect the most appropriate to heel bone injury severity variants of reconstructive osteosynthesis it was analyzed treatment results of 56 patients. In 15 (26.8% patients classic methods of surgical service were applied, in 41 (73.2% cases to restore the defect porous implants were used. Osteosynthesis without heel bone plastic restoration accomplishment was ineffective in 60% patients from control group. Reconstructive osteosynthesis method ensures long-term good functional effect of rehabilitation in 96.4% patients from the basic group.

  9. Minimally invasive plate osteosynthesis for humeral shaft fracture: a reproducible technique with the assistance of an external fixator.

    Science.gov (United States)

    Lee, Hyun-Joo; Oh, Chang-Wug; Oh, Jong-Keon; Apivatthakakul, Theerachai; Kim, Joon-Woo; Yoon, Jong-Pil; Lee, Dong-Joo; Jung, Jae-Wook

    2013-05-01

    Minimally invasive plate osteosynthesis (MIPO) has become a popular option for treatment of humeral shaft fractures. However, indirect reduction might risk unpromising results, with mal-alignment/mal-union or nonunion. The purpose of this study was to describe a reproducible MIPO technique that used an external fixator during the procedure as a tool for reduction and maintenance, and to assess the outcomes in patients with humeral shaft fracture. Of 31 consecutive cases of humeral shaft fracture in 30 patients, 29 were included in this study. There were seven simple (type A) and 22 comminuted (type B or C) fractures. After the insertion of one Schanz pin on each proximal and distal humerus, a provisional reduction was achieved by connecting the pins with a monolateral external fixator. The MIPO procedure was then performed over the anterior aspect of the humerus. To evaluate the efficacy of the provisional reduction by external fixator, coronal and sagittal alignments were assessed. We also assessed bony and functional results, including complications, from this technique. There was no case of mal-union >10°, and mean angulation was 1.3° (range 0°-9°) in the coronal plane and 1.2° (range 0°-8°) in the sagittal plane. Twenty-eight of 29 fractures were united, including three delayed unions, with a mean union time of 19.1 weeks (range 12.3-38.4 weeks) and a mean follow-up of 20.8 months (range 13.5-31.0 months). There was one hypertrophic nonunion that healed after fixing with two additional screws. Except one patient with associated injury in the elbow, all patients recovered to pre-injury joint motion. There were two cases of postoperative radial nerve palsy that both recovered completely. We attributed them to manipulation, and not to the Schanz pins or plate fixation. Surgical treatment of humeral shaft fractures with external fixator-assisted reduction and MIPO resulted in excellent reductions and high union rates.

  10. High risk for revision after shoulder arthroplasty for failed osteosynthesis of proximal humeral fractures

    DEFF Research Database (Denmark)

    Kristensen, Marc Randall; Rasmussen, Jeppe Vejlgaard; Elmengaard, Brian

    2018-01-01

    Background and purpose - It is unclear whether previous osteosynthesis is a risk factor for inferior outcome following shoulder arthroplasty for a proximal humeral fracture. We used data from the Danish Shoulder Arthroplasty Registry (DSR) to examine this question. Patients and methods - All 285...... patients treated with a shoulder arthroplasty after failed osteosynthesis of a proximal humeral fracture reported to DSR from 2006 to 2013 were included. Each case was matched with 2 controls (570) treated with a primary shoulder arthroplasty for an acute proximal humeral fracture. Patient reported outcome...... for a shoulder arthroplasty after failed osteosynthesis was 2 with a primary arthroplasty for fracture as reference. In a separate analysis of patients treated by locking plate the mean WOOS was 46 (24), with a relative risk of revision at 1.5 with a primary arthroplasty as reference. Interpretation - Compared...

  11. Stability of radial head and neck fractures: a biomechanical study of six fixation constructs with consideration of three locking plates.

    Science.gov (United States)

    Burkhart, Klaus Josef; Mueller, Lars P; Krezdorn, David; Appelmann, Philipp; Prommersberger, Karl J; Sternstein, Werner; Rommens, Pol M

    2007-12-01

    Open reduction and internal fixation of radial neck fractures can lead to secondary loss of reduction and nonunion due to insufficient stability. Nevertheless, there are only a few biomechanical studies about the stability achieved by different osteosynthesis constructs. Forty-eight formalin-fixed, human proximal radii were divided into 6 groups according to their bone density (measured by dual-energy x-ray absorptiometry). A 2.7-mm gap osteotomy was performed to simulate an unstable radial neck fracture, which was fixed with 3 nonlocking implants: a 2.4-mm T plate, a 2.4-mm blade plate, and 2.0-mm crossed screws, and 3 locking plates: a 2.0-mm LCP T plate, a 2.0-mm 6x2 grid plate, and a 2.0-mm radial head plate. Implants were tested under axial (N/mm) and torsional (Ncm/ degrees ) loads with a servohydraulic materials testing machine. The radial head plate was significantly stiffer than all other implants under axial as well as under torsional loads, with values of 36 N/mm and 13 Ncm/ degrees . The second-stiffest implant was the blade plate, with values of 20 N/mm and 6 Ncm/ degrees . The weakest implants were the 2.0-mm LCP, with values of 6 N/mm and 2 Ncm/ degrees , and the 2.0-mm crossed screws, with values of 18 N/mm and 2 Ncm/ degrees . The 2.4-mm T plate, with values of 14 N/mm and 4 Ncm/ degrees , and the 2.0-mm grid plate, with values of 8 N/mm and 4 Ncm/ degrees came to lie in the midfield. The 2.0-mm angle-stable plates-depending on their design-allow fixation with comparable or even higher stability than the bulky 2.4-mm nonlocking implants and 2.0-mm crossed screws.

  12. New technique for fixing rib fracture with bioabsorbable plate.

    Science.gov (United States)

    Oyamatsu, Hironori; Ohata, Norihisa; Narita, Kunio

    2016-09-01

    Fixation of a bone fracture with a bioabsorbable plate made of poly-L-lactide and hydroxyapatite has received attention. We adopted this technique for a rib fracture by bending the plate into a U-shape and fixing it with suture through the holes in the mesh of the plate and holes that are drilled in the edge of the fractured rib. The suture is also wound around the plate. © The Author(s) 2016.

  13. Internal fixation of mandibular angle fractures using one miniplate in Greek children: a 5-year retrospective study.

    Science.gov (United States)

    Iatrou, Ioannis; Theologie-Lygidakis, Nadia; Tzermpos, Fotios; Kamperos, Georgios

    2015-01-01

    Treatment modalities of mandibular angle fractures (MAFs) have been analyzed in several studies mainly referring to adult populations. The aim of this study was to retrospectively present and discuss our experience and literature findings regarding the treatment of MAFs in children. Data were retrieved from the files of the Oral and Maxillofacial department, at the Children's Hospital ''P. & A. Kyriakou'' of Athens, during a 5 years period (2009-2013). Demographic features, treatment methods, outcome and follow-up of all patients with mandibular angle fractures were recorded. 6 boys, 5-14 years old (mean age 10 years), were included in the study. They were all treated intraorally with open reduction and fixation via one monocortical titanium plate osteosynthesis at the external oblique line of the mandible, followed by 1 week of intermaxillary fixation (IMF). Plates were removed 3-12 months post-operatively. Follow-up period ranged from 12 to 18 months (mean 14.7 months). All fractures healed uneventfully and the patients tolerated well both the operation and the post-operative period. Osteosynthesis via intraoral approach combined with short duration IMF is adequate in treating MAFs in children. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  14. Minimally invasive plate osteosynthesis of humeral shaft fractures: a technique to aid fracture reduction and minimize complications.

    Science.gov (United States)

    Shin, Sang-Jin; Sohn, Hoon-Sang; Do, Nam-Hoon

    2012-10-01

    To introduce a modified operative technique for minimally invasive plate osteosynthesis (MIPO) for acute displaced humeral shaft fractures and to evaluate the clinical and radiological outcomes. : Prospective clinical series study. University hospital. Twenty-one patients with acute displaced humeral shaft fractures were treated by MIPO with a modified fracture reduction technique. A narrow 4.5/5.0-mm locking compression plate was applied to the anterior aspect of the humerus. Fracture reduction and manipulation were performed using a plate and drill bits. The operating time, time to union, humeral alignment, and functional outcome of the shoulder and elbow joints were evaluated using the University of California Los Angeles shoulder score and Mayo elbow performance score. No patient experienced a neurological complication. Bony union was obtained in 20/21 patients at a mean 17.5 weeks postoperatively. Eighteen patients had excellent and 3 patients had good results in the University of California Los Angeles score. The average Mayo elbow performance score was 97.5. Two patients were converted to an open reduction during operation due to a failure of MIPO. There was 1 nonunion and 1 malunion in this series. Although the MIPO technique for humeral shaft fractures is technically demanding, satisfactory clinical outcomes in terms of bony union and shoulder and elbow function can be obtained using the modified fracture reduction method. Potential postoperative complications, such as malreduction and nonunion, must be considered. Appropriate surgical indications, a thorough understanding of the neurovascular anatomy and skillful surgical technique, are needed to reduce potential complications.

  15. Joining by plating: optimization of occluded angle

    International Nuclear Information System (INIS)

    Dini, J.W.; Johnson, H.R.; Kan, Y.R.

    1978-11-01

    An empirical method has been developed for predicting the minimum angle required for maximum joint strength for materials joined by plating. This is done through a proposed power law failure function, whose coefficients are taken from ring shear and conical head tensile data for plating/substrate combinations and whose exponent is determined from one set of plated-joint data. Experimental results are presented for Al-Ni-Al (7075-T6) and AM363-Ni-AM363 joints, and the failure function is used to predict joint strengths for Al-Ni-Al (2024-T6), UTi-Ni-UTi, and Be-Ti-Be

  16. Role of Appositional Screw Fixation in Minimally Invasive Plate Osteosynthesis for Distal Tibial Fracture.

    Science.gov (United States)

    Yang, Kyu-Hyun; Won, Yougun; Kang, Dong-Hyun; Oh, Jin-Cheol; Kim, Sung-Jun

    2015-09-01

    To determine the effect of interfragmentary appositional (gap-closing) screw fixation in minimally invasive plate osteosynthesis (MIPO) for distal tibial fractures on the clinical and radiologic results. Prospective nonrandomized study. Level I trauma center. Sixty patients who were diagnosed as distal metadiaphyseal oblique or spiral tibial fracture without displaced articular fragment. Thirty patients (group A) of the 60 patients were treated with MIPO without appositional screw fixation, and the other 30 (group B) were treated with the screw. Radiologic union, clinical union, clinical functional score [American Orthopaedic Foot and Ankle Society (AOFAS) score], and complications. The time for initial callus formation and radiologic union was significantly longer in group A than those in group B (76.8 vs. 58.0 days, P = 0.044; 409 vs. 258.7 days, P = 0.002, respectively). The rate of clinical union during 1 year was significantly higher in group B than in group A (P = 0.0063). Four nonunion patients in group A achieved bone union after placement of an additional bone graft. None of the patients in group B diagnosed with delayed union or nonunion (P fracture promoted callus formation and union rate compared with MIPO without appositional screw fixation. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  17. Biomechanical analysis of the effect of occlusal force on osteosynthesis following sagittal split ramus osteotomy

    International Nuclear Information System (INIS)

    Okuda, Katsuya; Nakajima, Masahiro; Kakudo, Kenji

    2009-01-01

    Relapse is sometimes observed during the postoperative course following sagittal split ramus osteotomy which is widely used to correct jaw deformities. Relapse may be caused by biomechanical factors such as the postoperative occlusal force. We evaluated serial changes in the stress distribution associated with postoperative occlusal force and jaw-closing pressure on the mandible and osteosynthesis plate using three-dimensional finite element analysis. Based on CT data, we produced mandibular models 1, 3, 6, and 12 months after sagittal split ramus osteotomy, and subjected them to simulated occlusal force and jaw-closing pressure. Changes in equivalent stress in the proximal and distal segments, at the osteosynthesis site, and the fixation plate were evaluated by three-dimensional finite element analysis. The equivalent stresses in the proximal and distal segments slightly increased over time from 1 to 12 months after the operation. In particular, marked stress concentration was observed at the anterior border of the ramus at each measurement area. Stress at the osteosynthesis site increased from 1 to 6 months after the operation, but decreased after 12 months. As a result of postoperative occlusal forces and jaw-closing pressure, stress was concentrated at the anterior border of the ramus in the proximal segment. Between 3 and 6 months after the operation, tensile stress was concentrated at the upper and lower ends of the osteotomy line at the osteosynthesis site. These biomechanical findings indicate the application of clockwise stress on the distal segment up to 6 months after the operation. We concluded that sagittal split ramus osteotomy runs the risk of relapse between 3 and 6 months after the operation. (author)

  18. Interference in a thick plate at large angle of incidence

    International Nuclear Information System (INIS)

    Tavassoli, M.T.; Shah Shehany, F.

    1991-01-01

    A new approach to the interference in a plane parallel plate is introduced which is valid for any angle of incidence and any thickness. It is shown that the interference in a plate can be interpreted as the interference in a double-slit and the corresponding parameters are derived. It is also shown that for a particular angle of incidence, which depends only on the refractive index, the interfringes are minimum. It is proved theoretically and verified experimentally that the interference around this particular angle of incidence has several exploitable features which include: a) In thick plates large numbers of equidistant fringes are formed which are very adequate for producing interference gratings. b) It provides, in comparison to the conventional interferometric methods, an easier and more accurate means for direct measurement of wave-length. c) Multiple-beam interference at this particular angle improve the accuracy of the measurement of the fine structures of the atomic spectra, compared to other interferometric methods. (author). 4 refs, 4 figs

  19. Air loads on a rigid plate oscillating normal to a fixed surface

    NARCIS (Netherlands)

    Beltman, W.M.; van der Hoogt, Peter; Spiering, R.M.E.J.; Tijdeman, H.

    1997-01-01

    This paper deals with the theoretical and experimental investigation on a rigid, rectangular plate oscillating in the proximity of a fixed surface. The plate is suspended by springs. The airloads generated by the oscillating motion of the plate are determined. Due to the fact that the plate is

  20. Determination of metallosis after AO plate osteosynthesis by means of instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Blettenberg, G.

    1975-01-01

    The instrumental neutron activation analysis was used to determine metallosis after osteosynthesis in 11 samples of contact tissues and 6 samples of fascial tissues by means of AO-plates made of stainless steel. The concentrations of the elements specific for stainless steels such as Fe, Cr, Ni as well as the content of the elements unspecific for steel such as Zn, Co, Rb, Se, Cs, Sb, Sc, and Ag were determined. 7 samples of the contact tissue showed strong metallosis changes and 3 samples showed light metallosis changes which manifested themselves by increased Cr or Ni-concentrations and in 5 cases by increased Fe-content. 1 contact tissue sample did not show any metallosis changes. The 11 samples of contact tissue showed mainly decreased concentrations of Zn, Rb, Se, Cs. In the contact tissue samples which were strongly metallotic Co was to be found in an increased amount. The elements Sb, Sc, and Ag existed in the contact tissue samples in normal concentration. In the fascial samples examined increased Cr and Ni-concentrations indicated metallosis changes. The Fe-concentrations in the fascial changes were within the norm. The content of Zn, Rb, Cs, and Se in the fascial samples were decreased, while the concentrations of Sb, Co, Sc, and Ag were within the normal range. (orig./MG) [de

  1. [Osteosynthesis of Weber B ankle fractures using the one-third tubular plate and refixation of the syndesmosis].

    Science.gov (United States)

    Spering, C; Lesche, V; Dresing, K

    2015-08-01

    Anatomical reconstruction and recovery to complete range of function of the upper ankle joint. Therefore, the most stable but least invasive osteosynthesis is required to enable the patient early functional mobilization. Supination and pronation fracture with luxation mechanism of the upper ankle joint with or without rupture of the syndesmosis. Open fracture of the distal fibula including displaced and instable fractures. Severe peripheral arterial occlusive disease; contaminated open fractures (≥ 2nd degree); pediatric fractures with open epiphyseal plate. Supine position with ipsilateral slightly elevated hip and knee. Incision of about 8 cm length along the dorsal edge of the distal fibula. When reaching the lateral malleolus, a slight ventral angulation is necessary. Open reduction through this posterolateral approach. Secure the reposition using an interfragmentary lag screw and anatomically adjusted third tubular plate. Followed by a revision of the syndesmosis and transfixation using a tricortical position screw. Mobilization on day 1 after surgery with reduced weight-bearing when position screw is not applied; when position screw is implanted with ground contact for 6 weeks. Removal of position screw under local anesthesia after 6 weeks and pain-controlled full weight-bearing. Removal of metal after 1.5 years. Open reduction using the third tubular plate and an interfragmentary lag screw through a dorsolateral approach used in 90 % of all Weber B fractures in our clinic. Additional revision of a ruptured syndesmosis performed in 70 % and transfixation through a position screw in 40 %. Persisting instability in the upper ankle joint significantly reduced after surgical treatment compared to a conservative approach. Revisions necessary in 3.7 % of patients and pseudarthrosis diagnosed in 0.9 %. It has been shown that the preoperative x-ray and clinical examination is limited in detecting a ruptured syndesmosis.

  2. Comparative characteristics of osteosynthesis techniques in patients with comminuted diaphyseal femoral fractures

    Directory of Open Access Journals (Sweden)

    A. P. Barabash

    2013-01-01

    Full Text Available The comparative analysis of the results of the surgical treatment of 130 patients with closed comminuted unilateral diaphyseal femoral fractures, including assessment of anatomic functional outcomes of treatment according to the technique of the standardized investigations in traumatology and orthopedy and determination of quality of life according to SF-36 method is carried out. Osteosynthesis with the help of external fixation devices was performed in 36 patients, intramedullary interlocking osteosynthesis - in 57 patients, compression plating - in 37 patients. Level of anatomic functional rehabilitation of the patients in the early postoperative period made up 69-79 %, 6 months later increased up to 74-92%, and after the expiration of 12 months the level of rehabilitation reached 85-99%. During the treatment quality of life concerning physical component was within the limits from 36,8 up to 55,5 %, and concerning mental component - 54,3-60,8 %. After the expiration of a year increase in the parameters of physical and mental components up to 55,7 - 59,8 % and 57,2-65,8 % is detected respectively. In the group where the transosseous osteosynthesis technique was applied we got 93,7-95 % of positive outcomes, with the average disability period of 212,3±18,1 days. In 47,2 % of cases the following complications are observed: knee contracture - 7; inflammation of the soft tissues located near the transosseous fixators - 5 (13,9%; shortening of the limb less than 5% of its length - 3; false joint formation - 1; fracture union with formation of varus deformity in the femoral bone - 1. When using intramedullary interlocking osteosynthesis we had positive results in 96,5 % of cases, with the average period of disability 176±17,8 days. In 10,5 % cases the following complications are observed: suture sinus - 1(1,75 %; femoral osteomyelitis - 1; break of the design - 1; false joint formation - 1; knee contracture - 1; shortening of the limb less than 5

  3. Biomechanical analysis of clavicle hook plate implantation with different hook angles in the acromioclavicular joint.

    Science.gov (United States)

    Hung, Li-Kun; Su, Kuo-Chih; Lu, Wen-Hsien; Lee, Cheng-Hung

    2017-08-01

    A clavicle hook plate is a simple and effective method for treating acromioclavicular dislocation and distal clavicle fractures. However, subacromial osteolysis and peri-implant fractures are complicated for surgeons to manage. This study uses finite element analysis (FEA) to investigate the post-implantation biomechanics of clavicle hook plates with different hook angles. This FEA study constructed a model with a clavicle, acromion, clavicle hook plate, and screws to simulate the implantation of clavicle hook plates at different hook angles (90°, 95°, 100°, 105°, and 110°) for treating acromioclavicular joint dislocations. This study investigated the biomechanics of the acromion, clavicle, hook plate, and screws. A smaller hook angle increases the stress on the middle third of the clavicle. A larger hook angle increases the force exerted by the clavicle hook plate on the acromion. The screw at the most medial position on the plate generated the highest stress. The highest stress on the implanted clavicle hook plate was on the turning corner of the hook. A clavicle hook plate with different hook angles may induce different biomechanical behaviors in the clavicle and acromion. Orthopedic surgeons must select a suitable clavicle hook plate based on the anatomical structure of each patient.

  4. Osteosíntesis maxilofacial con materiales reabsorbibles Maxillofacial osteosynthesis with resorbable material

    Directory of Open Access Journals (Sweden)

    J.L. López-Cedrún Cembranos

    2004-12-01

    Full Text Available La popularización de la combinación de ácidos poliláctico y poliglicólico ha hecho que estos nuevos materiales se utilicen cada vez más en la osteosíntesis maxilofacial, no solo en su aplicación pediátrica, sino también en adultos. Aunque todavía presentan algunas desventajas en relación con el titanio, como la mayor incomodidad de uso y el coste económico, la experiencia acumulada demuestra que es una alternativa válida a la osteosíntesis con titanio en la mayoría de las situaciones clínicas. En este artículo se analizan las características y cualidades de los materiales reabsorbibles empleados en osteosíntesis maxilofacial. Así mismo, se discuten las ventajas y desventajas de ambos tipos de osteosíntesis y se documentan las indicaciones actuales de la osteosíntesis reabsorbible basándonos en nuestra experiencia y en la revisión de la literatura.Resorbable plates and screws composed of polylactic and polyglycolic acid, as internal fixation devices have gained widespread use during recent years in pediatric and also adult patients. Although these materials show some disadvantages when compared with titanium plates, such as discomfort and economical cost, accumulated experience shows that resorbable ostheosynthesis is a reliable alternative to the titanium osteosynthesis used in most clinical cases. In this paper we analyze the main characteristics of resorbable materials used in maxillofacial osteosynthesis. We discuss the advantages and disadvantages of both types of osteosynthesis and the indications for resorbable ostheosynthesis at the present time, based on our experience and on a revision of the literature.

  5. [Humerus varus: correction by proximal valgus osteotomy with precontourned plate fixation in children].

    Science.gov (United States)

    Tallón-López, J; Domínguez-Amador, J J; Andrés-García, J A

    2014-01-01

    Varus deformity of the proximal humerus in children is a little known pathology due to its low incidence of presentation. Progress has been made in recent years in understanding the possible etiology and pathophysiological causes. Radiological criteria for diagnosis and functional impairment that occurs have also been defined. However, there are few reports in the literature about the surgical treatment of this deformity in children. In this paper we present a case of surgical treatment of this deformity by corrective osteotomy fixed with precontoured external maleolar plate osteosynthesis. Copyright © 2013 SECOT. Published by Elsevier Espana. All rights reserved.

  6. Effectiveness of sonography assisted minimal invasive plate osteosynthesis (MIPO) compare with fluoroscope assisted in femoral shaft fracture: A cadaveric study.

    Science.gov (United States)

    Saengsin, Jirawat; Vaseenon, Tanawat; Pattamapaspong, Nuttaya; Kritsaneephaiboon, Apipop

    2017-08-01

    A minimal invasive plate osteosynthesis (MIPO) has an advantage of biological soft tissue preservation that consists of preserving bony blood supply, fracture hematoma and less soft tissue damage which leads to decreasing of infection rate and rapid bone healing. However, the radiation exposure is still a disadvantage of this technique. A sonography that provides dynamic real time imaging may be used as an alternative technique for assisting MIPO. The aim of this study was to compare the effectiveness of MIPO in femoral shaft fracture between the sonography assisted and the fluoroscopy assisted. Twenty-eight cadaveric limbs were subjected to create femoral shaft fracture. Then, sonography assisted reduction with temporary external fixation and MIPO were performed. Images of the sonography and the fluoroscopy were recorded including before reduction, after reduction and after MIPO in order to identify fracture displacements in anteroposterior and mediolateral directions. Moreover, the anterior and posterior distances from edge of the bone to the plate were measured to confirm plate position. The effectiveness of this technique was defined as the proper plate position and acceptable alignment after fixation. All distances from the sonography and the fluoroscopy were also analyzed and compared using Pearson correlation and Bland-Altman method to assess the agreements between two tests. All of the subjects were met the criteria for acceptable alignment. We found only three femoral shaft fracture (11%) operated with MIPO by sonography assisted that showed slipped plate off femoral bones. According to Pearson correlation, there were good to excellent agreements in term of measuring fracture displacement before (Pearson Correlation >0.7) and after reduction (Pearson Correlation >0.7) between these two tests. There was moderate agreement regarding to evaluation of plate position (Pearson Correlation 03.-0.7). When we compared two methods of measurement using Bland

  7. Multiple exchange and high-energy fixed-angle scattering

    CERN Document Server

    Halliday, I G; Orzalesi, C A; Tau, M

    1975-01-01

    The application of the eikonal ansatz to fermion fermion elastic scattering with Abelian vector gluon exchanges is discussed. The behaviours of the elastic scattering amplitude and the elastic form factor are considered and an important mechanism for fixed angle high energy elastic scattering is identified. (6 refs).

  8. Staged minimally invasive plate osteosynthesis of proximal tibial fractures with acute compartment syndrome.

    Science.gov (United States)

    Kim, Joon-Woo; Oh, Chang-Wug; Oh, Jong-Keon; Kyung, Hee-Soo; Park, Kyeong-Hyeon; Kim, Hee-June; Jung, Jae-Wook; Jung, Young-Soo

    2017-06-01

    High-energy proximal tibial fractures often accompany compartment syndrome and are usually treated by fasciotomy with external fixation followed by secondary plating. However, the initial soft tissue injury may affect bony union, the fasciotomy incision or external fixator pin sites may lead to postoperative wound infections, and the staged procedure itself may adversely affect lower limb function. We assess the results of staged minimally invasive plate osteosynthesis (MIPO) for proximal tibial fractures with acute compartment syndrome. Twenty-eight patients with proximal tibial fractures accompanied by acute compartment syndrome who underwent staged MIPO and had a minimum of 12 months follow-up were enrolled. According to the AO/OTA classification, 6 were 41-A, 15 were 41-C, 2 were 42-A and 5 were 42-C fractures; this included 6 cases of open fractures. Immediate fasciotomy was performed once compartment syndrome was diagnosed and stabilization of the fracture followed using external fixation. After the soft tissue condition normalized, internal conversion with MIPO was done on an average of 37 days (range, 9-158) after index trauma. At the time of internal conversion, the external fixator pin site grades were 0 in 3 cases, 1 in 12 cases, 2 in 10 cases and 3 in 3 cases, as described by Dahl. Radiographic assessment of bony union and alignment and a functional assessment using the Knee Society Score and American Orthopedic Foot and Ankle Society (AOFAS) score were carried out. Twenty-six cases achieved primary bony union at an average of 18.5 weeks. Two cases of nonunion healed after autogenous bone grafting. The mean Knee Society Score and the AOFAS score were 95 and 95.3 respectively, at last follow-up. Complications included 1 case of osteomyelitis in a patient with a grade IIIC open fracture and 1 case of malunion caused by delayed MIPO due to poor wound conditions. Duration of external fixation and the external fixator pin site grade were not related to the

  9. Flexural-torsional buckling analysis of angle-bar stiffened plates

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, Rahbar Ranji [Amirkabir University of Technology, Tehran (Iran, Islamic Republic of)

    2015-09-15

    The interaction of flexural-torsional buckling modes is critical for stiffened plates with asymmetric stiffeners. However, this interaction is ignored in all design rules because it is complex to characterize. In the literature, the presence of an attached plate is ignored, and stiffened plate is treated as an ordinary asymmetric beam. In the flexural buckling mode, stiffener and the attached plate buckle together; in the torsional buckling mode, the attached plate cannot freely rotate with stiffener. Basic equations of the flexural-torsional buckling modes are deduced based on hybrid beam concept and a new strain distribution assumption for sideway bending of stiffeners. Elastic buckling stresses of different angle-bar stiffened plates are calculated and compared with those generated by the Finite element method (FEM) and those available in the literature. The present method has better agreements with FEM.

  10. Locking plate fixation in distal metaphyseal tibial fractures: series of 79 patients.

    Science.gov (United States)

    Gupta, Rakesh K; Rohilla, Rajesh Kumar; Sangwan, Kapil; Singh, Vijendra; Walia, Saurav

    2010-12-01

    Open reduction and internal fixation in distal tibial fractures jeopardises fracture fragment vascularity and often results in soft tissue complications. Minimally invasive osteosynthesis, if possible, offers the best possible option as it permits adequate fixation in a biological manner. Seventy-nine consecutive adult patients with distal tibial fractures, including one patient with a bilateral fracture of the distal tibia, treated with locking plates, were retrospectively reviewed. The 4.5-mm limited-contact locking compression plate (LC-LCP) was used in 33 fractures, the metaphyseal LCP in 27 fractures and the distal medial tibial LCP in the remaining 20 fractures. Fibula fixation was performed in the majority of comminuted fractures (n = 41) to maintain the second column of the ankle so as to achieve indirect reduction and to prevent collapse of the fracture. There were two cases of delayed wound breakdown in fractures fixed with the 4.5-mm LC-LCP. Five patients required primary bone grafting and three patients required secondary bone grafting. All cases of delayed union (n = 7) and nonunion (n = 3) were observed in cases where plates were used in bridge mode. Minimally invasive plate osteosynthesis (MIPO) with LCP was observed to be a reliable method of stabilisation for these fractures. Peri-operative docking of fracture ends may be a good option in severely impacted fractures with gap. The precontoured distal medial tibial LCP was observed to be a better tolerated implant in comparison to the 4.5-mm LC-LCP or metaphyseal LCP with respect to complications of soft tissues, bone healing and functional outcome, though its contour needs to be modified.

  11. Proximal Femoral Morphology and the Relevance to Design of Anatomically Precontoured Plates: A Study of the Chinese Population

    Directory of Open Access Journals (Sweden)

    Kun-Jhih Lin

    2014-01-01

    Full Text Available Adequately shaped femoral plate is critical for the fixation of fracture in the pertrochanteric regions. Lateral aspect of greater trochanter is an important region where the proximal femoral plate anchored. However, little is known regarding the morphology of greater trochanter. The objective of this study was to measure main dimensions of greater trochanter and other regions in the proximal end of the femur to provide an anatomical basis for the design of the proximal femoral plate. Anthropometric data on the proximal femur were performed utilizing three-dimensional computational modeling. Computed tomography images of healthy femurs in 53 women and 47 men were contributed to three-dimensional femur modeling. All data were compared between male and female femora. The results showed that mean values for male group were found to be greater in most of measured femoral dimensions. Oppositely, females demonstrated higher neck-shaft angle on anteroposterior view and femoral anteversion angle. The anthropometric data can be used for the anatomical shape design of femoral plates for osteosynthesis of fractures in the trochanteric regions. A distinct plate design may be necessary to accommodate differences between the genders.

  12. [Comparative study on the strength of different mechanisms of operation of multidirectionally angle-stable distal radius plates].

    Science.gov (United States)

    Rausch, S; Hoffmeier, K; Gueorguiev, B G; Klos, K; Gras, F; Hofmann, G O; Mückley, T

    2011-12-01

    Polyaxial angle-stable plating is thought to be particularly beneficial in the management of complex intra-articular fractures of the distal radius. The present study was performed to investigate the strength of polyaxial locking interfaces of distal radius plates. We tested the polyaxial interfaces of 3 different distal radius plates (2.4 mm Variable Angle LCP Two-Column Volar Distal Radius Plate, Synthes, Palmar Classic, Königsee Implantate and VariAx Plate Stryker). The strength of 0° and 10° screw locking angle was obtained during static loading. The strength of Palmar Classic with a 0° locking angle is significantly the best of all tested systems. With a 10° locking angle there is no significant difference between Palmar Classic, Two column Plate and VariAx Plate. The strength of polyaxial interfaces differs between the tested systems. A reduction of ultimate strength is due to increases of screw locking angle. The design of polyaxial locking interfaces should be investigated in human bone models. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Osteosynthesis for symptomatic ulnar styloid nonunion

    International Nuclear Information System (INIS)

    Kajiwara, Ryoji; Kimori, Kenji; Kawagoe, Hiroyuki; Tsuge, Kenya; Ikuta, Yosikazu

    2008-01-01

    We reviewed cases of osteosynthesis for symptomatic ulnar styloid nonunion. Since 1998, 13 cases of ulnar styloid nonunion have been treated by osteosynthesis. The patients were 10 men and 3 women, with a mean age of 27 years (range 11-65). The nonunion site was located in the middle in one case, in the base in 8 cases, and in the epiphyseal region in 4 cases. Osteosynthesis was performed with tension band wiring in all cases, and cancellous bone graft was performed in 12 of 13 cases. Distal radioulnar joint (DRUJ) instability was found by radiograph or CT in four cases; in two of these, osteosynthesis alone did not improve DRUJ instability and additional DRUJ stabilization was performed. One patient whose treatment failed to correct nonunion did not seek further treatment. In another case, an additional surgery was performed 1 week after the initial surgery to correct displacement of the fragment. The mean follow-up period was 15 months (range 8-45 months). According to Hauck's criteria, final pain was evaluated as excellent in nine cases, good in three cases, including the case resulting in nonunion, and fair in one case. (author)

  14. Effectiveness of Minimally Invasive Plate Osteosynthesis (MIPO on Comminuted Tibial or Femoral Fractures

    Directory of Open Access Journals (Sweden)

    Ali Andalib

    2017-09-01

    Full Text Available Background: Comminuted fractures happen frequently due to traumas. Fixation without opening the fracture site,known as minimally invasive plate osteosynthesis (MIPO, has recently become prevalent. This study has beendesigned to assess the outcomes of this treatment for tibial and femoral comminuted fractures.Methods: A total of 60 patients with comminuted femoral or tibial fractures were operated with MIPO method in thiscross-sectional study at Alzahra university hospital in 2015. Eleven patients were excluded due to lack of adequatefollow-ups. Patients’data including union time; infection in the fractured site; hip and knee range of motion; and anymalunion or deformities like limb length discrepancy were collected after the surgery in every session.Results: Among 32 femoral and 17 tibial fractures, union was completed in48 patients, while only one patient withfemoral fracture had nonunion. The mean union time was 18.57±2.42 weeks. Femur fractures healed faster than tibia(17.76±2.36 compared to 19±2.37 weeks, respectively, P=0.09. None of the patients suffered from infections or fistula.The range of motion in hip and knee remained intact in approximately all patients. Malunion happened in 3 patients; 100internal rotation in 1 patient; and 1cm limb shortening in 2 patients.Conclusion: According to the result of this study, MIPO is a simple and effective method of fixation with a high rateof union as well as minimal complications for comminuted fractures of long bones. Infection is rare, and malunion orany deformity is infrequent. MIPO appears to be a promising and safe treatment alternative for comminuted fractures.

  15. The prospects of biodegradable magnesium-based alloys in osteosynthesis

    Directory of Open Access Journals (Sweden)

    V. N. Chorny

    2013-12-01

    Full Text Available In the analytical review of the literature the main stages of development of biodegradable magnesium alloys in surgery and traumatology were discussed. The analysis revealed the main problems: there is no way to control the speed of the biological resorption alloys, the effects of products of magnesium degradation on the tissues and the organism in general are not studied, there is no information on the characteristics of the regeneration of bone tissue when implanted magnesium implanted magnesium alloys Materials for osteosynthesis with metal clamps made of steel X18H9T are used in 25,0-52,2% of cases, the corrosion of fasteners reaches 18-21%. Corrosion of the metal clips leads to the increase of the concentration of iron, chromium, nickel and titanium in the surrounding tissue. Electrochemical processes in metallic implants occurs due to their structural and chemical inhomogeneous. The microstructure of stainless steel is presented by differently oriented grains. Therefore, the question remains relevant to finding biodegradable materials suitable for implants for osteosynthesis, which could be completely metabolized by the organism, without causing of the pathological effects on the surrounding tissue and the body. The property of magnesium metal dissolved in the tissues of a living organism is known since the 19th century. Payr suggested the use of magnesium metal needles for the treatment of angiomas, in order to achieve thrombosis surrounding the tumor. In 1937 Lambotte made a post in the French Surgical Academy on the application of the osteosynthesis of the shin bone clamps with alloy Dow-metal (magnesium - 92% Aluminum - 8% + traces of manganese, made in the form of loops and screws. In 1938, Earl D. Mc.Braid and published their positive experience with plates and screws made of material similar in composition to the Dow-metal for osteosynthesis of fractures of the arm and forearm bones. Magnesium alloys may be used as a material for

  16. [Treatment of periprosthetic and peri-implant fractures : modern plate osteosynthesis procedures].

    Science.gov (United States)

    Raschke, M J; Stange, R; Kösters, C

    2012-11-01

    Periprosthetic fractures are increasing not only due to the demographic development with high life expectancy, the increase in osteoporosis and increased prosthesis implantation but also due to increased activity of the elderly population. The therapeutic algorithms are manifold but general valid rules for severe fractures are not available. The most commonly occurring periprosthetic fractures are proximal and distal femoral fractures but in the clinical routine fractures of the tibial head, ankle, shoulder, elbow and on the borders to other implants (peri-implant fractures) and complex interprosthetic fractures are being seen increasingly more. It is to be expected that in the mid-term further options, such as cement augmentation of cannulated polyaxial locking screws will extend the portfolio of implants for treatment of periprosthetic fractures. The aim of this review article is to present the new procedures for osteosynthesis of periprosthetic fractures.

  17. Fracture Characteristics Analysis of Double-layer Rock Plates with Both Ends Fixed Condition

    Directory of Open Access Journals (Sweden)

    S. R. Wang

    2014-07-01

    Full Text Available In order to research on the fracture and instability characteristics of double-layer rock plates with both ends fixed, the three-dimension computational model of double-layer rock plates under the concentrated load was built by using PFC3D technique (three-dimension particle flow code, and the mechanical parameters of the numerical model were determined based on the physical model tests. The results showed the instability process of the double-layer rock plates had four mechanical response phases: the elastic deformation stage, the brittle fracture of upper thick plate arching stage, two rock-arch bearing stage and two rock-arch failure stage; moreover, with the rock plate particle radius from small to large change, the maximum vertical force of double rock-arch appeared when the particle size was a certain value. The maximum vertical force showed an upward trend with the increase of the rock plate temperature, and in the case of the same thickness the maximum vertical force increased with the increase of the upper rock plate thickness. When the boundary conditions of double-layer rock plates changed from the hinged support to the fixed support, the maximum horizontal force observably decreased, and the maximum vertical force showed small fluctuations and then tended towards stability with the increase of cohesive strength of double-layer rock plates.

  18. Comparison of Alignment Correction Angles Between Fixed-Bearing and Mobile-Bearing UKA.

    Science.gov (United States)

    Inoue, Atsuo; Arai, Yuji; Nakagawa, Shuji; Inoue, Hiroaki; Yamazoe, Shoichi; Kubo, Toshikazu

    2016-01-01

    Good outcomes have been reported with both fixed-bearing and mobile-bearing unicompartmental knee arthroplasty (UKA). However, overcorrected alignment could induce the progression of arthritis on the non-arthroplasty side. Changes of limb alignment after UKA with both types of bearings (fixed bearing: 24 knees, mobile bearing: 28 knees) were investigated. The mean difference between the preoperative standing femoral-tibial angle (FTA) and postoperative standing FTA was significantly larger in mobile bearing UKA group. In fixed-bearing UKA, there must be some laxity in MCL tension so that a 2-mm tension gauge can be inserted. In mobile-bearing UKA, appropriate MCL tension is needed to prevent bearing dislocation. This difference in MCL tension may have caused the difference in the correction angle between the groups. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. An Evaluation of the Fixed Hotspot Hypothesis for the Pacific Plate

    Science.gov (United States)

    Wessel, P.; Kroenke, L. W.

    2008-12-01

    Using geometry and ages from 12 Pacific seamount chains, we recently constructed two new Pacific absolute plate motion models that extend our self-consistent and high-resolution models back to 145 Ma. The WK08-A model maps the full uncertainty in the age progressions into uncertainties in rotation opening angles, yielding a relatively smooth plate motion model. The WK08-G model relaxes the mapping of age uncertainties in order to better isolate secondary geometry changes seen along many co-registered chains. Both models have been used to assess the viability of the fixed hotspot hypothesis in the Pacific. In constructing these models, we found that only a small group of age samples had to be discarded on the grounds that they were discordant with the dominant trends. We were able to connect plate motions for pre- and post-Emperor age intervals by including the Ratak-Gilbert-Ellice, Liliuokalani and Musicians trails in our analysis. However, as no active hotspot locations exist for the older chains their inclusion adds additional model parameters. Both age and geometry misfits increase with age, reflecting the observed increase in age uncertainties and the broader and less distinct nature of the older trails. Paleomagnetic observations from the Emperor seamount chain have been interpreted to suggest that these seamounts must have formed at latitudes significantly more northerly than the present location of the Hawaii hotspot, implying a drifting mantle plume. At the same time, new estimates of the age of the Hawaii- Emperor bend places bend formation at a time of global plate reorganization. We will present a complete analysis of inter-chain distances between coeval radiometric samples from Pacific chains and compare these distances to the inter-hotspot distances at the present time. Significant departures from the current hotspot separations would be direct and unequivocal evidence of motion between the Pacific hotspot reference frame and the spin axis and as such

  20. Fixation of zygomatic and mandibular fractures with biodegradable plates

    OpenAIRE

    Degala, Saikrishna; Shetty, Sujeeth; Ramya, S

    2013-01-01

    Context: In this prospective study, 13 randomly selected patients underwent treatment for zygomatic?complex fractures (2 site fractures) and mandibular fractures using 1.5 / 2 / 2.5-mm INION CPS biodegradable plates and screws. Aims: To assess the fixation of zygomatic-complex and mandibular fractures with biodegradable copolymer osteosynthesis system. Materials and Methods: In randomly selected 13 patients, zygomatic-complex and mandibular fractures were plated using resorbable plates and sc...

  1. Radiographic evaluation of fracture healing after rigid plate fixation

    International Nuclear Information System (INIS)

    Paavolainen, P.; Karaharju, E.; Slaetis, P.; Waris, P.

    1981-01-01

    Experimental osteotomies were made in 35 rabbit tibio-fibular bones and fixed with rigid stainless steel osteosynthesis plates (DCP/ASIF). The radiographic and histopathologic appearances in the healing osteotomies and adjacent bone were analysed at intervals from 3 up to 24 weeks postoperatively. Radiologically the osteotomy had closed at 9 weeks and microscopically this could be confirmed as longitudinal orientation of the cutter heads across the osteotomy gap with longitudinal orientation of the bone structure. The healing of the osteotomy was accompanied by gross structural changes in the adjacent cortical bone with loss of intracortical and subendosteal osteons, cementing lines and intermediate tissue between the osteons. This was characterized by decreasing attenuation of the cortical bone after healing of the osteotomy and should clinically be regarded as an indication for removal of the implant. (Auth.)

  2. Osteosynthesis with long volar locking plates for meta- physeal-diaphyseal fractures of the distal radius

    Directory of Open Access Journals (Sweden)

    Gogna Paritosh

    2013-12-01

    Full Text Available 【Abstract】Objective: Metaphyseal-diaphyseal fractures of the distal radius are a major treatment dilemma and orthopaedic surgeons have to pay due consideration to restoration of anatomy of distal radius together with ro- tation of the radial shaft and maintenance of radial bow and interosseous space. We performed this study to evaluate the clinic-radiological outcome of metaphyseal-diaphyseal fractures of the distal radius treated with long volar locking plates. Methods: This prospective study involved 27 pa- tients (22 males and 5 females with metaphyseal-diaphy- seal fracture of the distal radius. Their mean age was (30.12± 11.48 years (range 19-52 years and the follow-up was 26.8 months (range 22-34 months. All patients underwent open reduction and internal fixation with a long volar locking plate. According to AO/OTA classification, there were 7 type A3, 13 type C2 and 7 type C3 fractures. Subjective assessment was done based on the disabilities of the arm, shoulder and hand (DASH questionnaire. Functional evaluation was done by measuring grip strength and range of motion around the wrist and the radiological determinants included radial angle, radial length, volar angle and ulnar variance. The final as- sessment was done according to Gartland and Werley scor- ing system. Results: Postoperative radiological parameters were well maintained throughout the trial, and there was signifi- cant improvement in the functional parameters from 6 weeks to final follow-up. The average DASH scores improved from 37.5 at 6 weeks to 4.2 at final follow-up. Final assessment using Gartland and Werley scoring system revealed 66.67% (n=18 excellent and 33.33% (n=9 good results. There was one case of superficial infection which responded to antibi- otics and another carpel tunnel syndrome which was ma- naged conservatively. Conclusion: Volar locking plate fixation for metaphy- seal-diaphyseal fractures of distal radius is associated with excellent to good

  3. Evaluation of a tracking flat-plate solar collector in Brazil

    International Nuclear Information System (INIS)

    Maia, Cristiana B.; Ferreira, André G.; Hanriot, Sérgio M.

    2014-01-01

    The continuing research for an alternative power source due to the perceived scarcity of fuel fossils has, in recent years, given solar energy a remarkable edge. Nevertheless, the Earth's daily and seasonal movement affects the intensity of the incident solar radiation. Devices can track the sun in order to ensure optimum positions with regard to incident solar radiation, maximizing the absorbed solar energy, and the useful energy gain. In this paper, a mathematical model is developed to estimate the solar radiation absorbed, the useful energy gain, and the efficiency of a flat-plate solar collector in Brazil. The results for a sun tracking flat-plate solar collector were compared to fixed devices. The full tracking system with rotation about two axes presented higher absorbed energy, when compared to the rotation about a single axe and to a fixed collector. Also, it was shown that the tilt angle for a fixed solar collector does not cause significant variations in the useful energy gain or in the absorbed solar radiation, for the same azimuth angle. - Highlights: • A model was developed for solar radiation based on experimental data for K T . • Useful energy gain and efficiency of a flat-plate solar collector were evaluated for a one-year period. • Several sun tracking systems were compared to fixed devices. • Tilt angle for a fixed device does not significantly affect the useful energy gain

  4. Novel management of distal tibial and fibular fractures with Acumed fibular nail and minimally invasive plating osteosynthesis technique: A case report.

    Science.gov (United States)

    Wang, Tie-Jun; Ju, Wei-Na; Qi, Bao-Chang

    2017-03-01

    Anatomical characteristics, such as subcutaneous position and minimal muscle cover, contribute to the complexity of fractures of the distal third of the tibia and fibula. Severe damage to soft tissue and instability ensure high risk of delayed bone union and wound complications such as nonunion, infection, and necrosis. This case report discusses management in a 54-year-old woman who sustained fractures of the distal third of the left tibia and fibula, with damage to overlying soft tissue (swelling and blisters). Plating is accepted as the first choice for this type of fracture as it ensures accurate reduction and rigid fixation, but it increases the risk of complications. Closed fracture of the distal third of the left tibia and fibula (AO: 43-A3). After the swelling was alleviated, the patient underwent closed reduction and fixation with an Acumed fibular nail and minimally invasive plating osteosynthesis (MIPO), ensuring a smaller incision and minimal soft-tissue dissection. At the 1-year follow-up, the patient had recovered well and had regained satisfactory function in the treated limb. The Kofoed score of the left ankle was 95. Based on the experience from this case, the operation can be undertaken safely when the swelling has been alleviated. The minimal invasive technique represents the best approach. Considering the merits and good outcome in this case, we recommend the Acumed fibular nail and MIPO technique for treatment of distal tibial and fibular fractures.

  5. The strength of polyaxial locking interfaces of distal radius plates.

    Science.gov (United States)

    Hoffmeier, Konrad L; Hofmann, Gunther O; Mückley, Thomas

    2009-10-01

    Currently available polyaxial locking plates represent the consequent enhancement of fixed-angle, first-generation locking plates. In contrast to fixed-angle locking plates which are sufficiently investigated, the strength of the new polyaxial locking options has not yet been evaluated biomechanically. This study investigates the mechanical strength of single polyaxial interfaces of different volar radius plates. Single screw-plate interfaces of the implants Palmar 2.7 (Königsee Implantate und Instrumente zur Osteosynthese GmbH, Allendorf, Germany), VariAx (Stryker Leibinger GmbH & Co. KG, Freiburg, Germany) und Viper (Integra LifeSciences Corporation, Plainsboro, NJ, USA) were tested by cantilever bending. The strength of 0 degrees, 10 degrees and 20 degrees screw locking angle was obtained during static and dynamic loading. The Palmar 2.7 interfaces showed greater ultimate strength and fatigue strength than the interfaces of the other implants. The strength of the VariAx interfaces was about 60% of Palmar 2.7 in both, static and dynamic loading. No dynamic testing was applied to the Viper plate because of its low ultimate strength. By static loading, an increase in screw locking angle caused a reduction of strength for the Palmar 2.7 and Viper locking interfaces. No influence was observed for the VariAx locking interfaces. During dynamic loading; angulation had no influence on the locking strength of Palmar 2.7. However, reduction of locking strength with increasing screw angulation was observed for VariAx. The strength of the polyaxial locking interfaces differs remarkably between the examined implants. Depending on the implant an increase of the screw locking angle causes a reduction of ultimate or fatigue strength, but not in all cases a significant impact was observed.

  6. Limited open reduction is better for simple- distal tibial shaft fractures than minimally invasive plate osteosynthesis.

    Science.gov (United States)

    Li, Q; Zeng, B F; Luo, C F; Song, S; Zhang, C Q; Kong, W Q

    2014-07-24

    The aim of this study was to compare the effects and indications of minimally invasive plate osteosynthesis (MIPO) and limited open reduction (LOR) for managing distal tibial shaft fractures. A total of 79 cases of distal tibial shaft fractures were treated surgically in our trauma center. The 79 fracture cases were classified into type A, B, and C (C1) according to the Arbeitsgemeinschaft für Osteosynthesefragen (AO) classification, with 28, 32, and 19 cases, respectively. Among the 79 fracture cases, 52 were closed fractures and 27 were open fractures (GUSTILO, I-II). After adequate preparation, 48 cases were treated with LOR and 31 cases were treated with MIPO. All cases were followed up for 12 to 18 months, with an average of 16.4 months. During the follow-up period, 76 fracture cases were healed in the first stage, whereas the 3 cases that developed non-union were treated by changing the fixation device and autografting. For types A, B, and some of C simple fractures (C1), LOR accelerated the fracture healing and lowered the non-union rate. One case suffered from regional soft tissue infection, which was controlled by wound dressing and intravenous antibiotics. Another case that developed local skin necrosis underwent local flap transplant. LOR promoted bone healing and lowered the non-union rate of several simple-distal tibial shaft fractures. Thereafter, the incidence of soft tissue complication was not significantly increased. However, for complex and comminuted fractures, MIPO was the preferred method for correcting bone alignment and protecting soft tissue, leading to functional recovery.

  7. Osteosynthesis of femoral neck fractures: dynamic hip screw (DHS or mini-invasive Targon FN system?

    Directory of Open Access Journals (Sweden)

    A. K. Dulaev

    2015-01-01

    Full Text Available Objectives: to investigate the long-term outcomes of femoral neck fractures that were surgically fixed using various types of extramedullary implants in patients aged 65 years and younger. Material and methods: We analyzed the clinical results of surgical treatment of femoral neck fractures by extramedullary osteosynthesis in 94 patients aged 38 to 65 years old (71 women and 23 men. The patients were divided into 3 groups according to AO/ASIF fracture classification. We used different techniques of osteosynthesis: with DHS or with Targon FN. In all patients the mental status rate SPMSQ, osteoporosis degree (Singh index, general somatic status (WHO scale were evaluated in the preoperative period. We also evaluated next intraoperative parameters: duration of surgery, blood loss, quality of reduction, long of incision. In a year after surgery we assessed functional results (Harris Hip Score and analysed postoperative complications. Results: It was found the inverse correlation (r = -0,8 of total preoperative parameters (WHO scale, the Singh index and mental status SPMSQ and postoperative functional results on Harris Hip Score. With the reliability of p<0.05 the average rate of blood loss and length of skin incision were less in patients operated with Targon FN. In 12 months unsatisfactory results rate on Harris Hip Score was 12.7% in all study groups, great - 22,3%, good - 52.1%, and satisfactory - 12,9%. Complications rate in patients operated with DHS was 17,02%, and in patients operated with Targon FN - 18.1%. Conclusion: Minimally invasive osteosynthesis of femoral neck fractures (type B1 and B2 on AO/ASIF classification allows to achieve the best results in compare with DHS osteosynthesis. Revealed complications such as screw migration, false joint formation and femoral head avascular necrosis were determined by impaired surgical technique and inadequate reduction.

  8. Optimum tilt angle for flat plate collectors all over the World – A declination dependence formula and comparisons of three solar radiation models

    International Nuclear Information System (INIS)

    Stanciu, Camelia; Stanciu, Dorin

    2014-01-01

    Highlights: • Monthly optimum tilt angle is predicted for North latitudes between 0° and 80°. • From practical considerations, an optimum fixed value all along the year is derived. • Three solar radiation models are compared from the point of view of total incident solar radiation density prediction. - Abstract: The paper presents a theoretical study on the optimum tilt angle for flat plate collectors at different geographical locations and different time moments over a year. The solar radiation density is estimated based on three analysis models, namely Hottel and Woertz model (the simplest), Isotropic diffuse model (Liu and Jordan model) and HDKR model (Hay–Davis–Klucker–Reindl), passing from the simplest to the most complex one. Further, the absorbed solar radiation density is computed and the optimum tilt angle is found for different geographical locations (covering the Globe latitudes). The optimum value for the tilt angle is researched for maximum incident solar radiation and also for maximum absorbed one. The results indicate that the same angle is obtained when looking for maximum incident and for maximum absorbed solar radiation. When comparing the three above mentioned models, different tilt angles are supplied by applying the Hottel and Woertz model and respectively the others two (both of them providing the same angle). Although, the predicted absorbed solar radiation is the same in the summertime for all three models, and probably overestimated by the last model in the springtime. The obtained results give an overview over the whole year operation at different geographical latitudes. When using the Hottel and Woertz model for estimating the incident solar radiation, the optimum tilt angle for a flat plate collector should be computed as simplest as β opt = φ − δ function on the latitude and declination. If a fixed value is easier to be used over a specific operation period, an optimum value is provided by this research. The novelty

  9. Fretting corrosion tests on orthopedic plates and screws made of ASTM F138 stainless steel

    OpenAIRE

    Santos,Claudio Teodoro dos; Barbosa,Cássio; Monteiro,Maurício de Jesus; Abud,Ibrahim de Cerqueira; Caminha,Ieda Maria Vieira; Roesler,Carlos Rodrigo de Mello

    2015-01-01

    Introduction Although there has been significant progress in the design of implants for osteosynthesis, the occurrence of failures in these medical devices are still frequent. These implants are prone to suffer from fretting corrosion due to micromotion that takes place between the screw heads and plate holes. Consequently, fretting corrosion has been the subject of research in order to understand its influence on the structural integrity of osteosynthesis implants. The aim of this paper is t...

  10. The effect of electrode vertex angle on automatic tungsten-inert-gas welds for stainless steel 304L plates

    International Nuclear Information System (INIS)

    Maarek, V.; Sharir, Y.; Stern, A.

    1980-03-01

    The effect of electrode vertex angle on penetration depth and weld bead width, in automatic tungsten-inert-gas (TIG) dcsp bead-on-plate welding with different currents, has been studied for stainless steel 304L plates 1.5 mm and 8 mm thick. It has been found that for thin plates, wider and deeper welds are obtained when using sharper electrodes while, for thick plates, narrower and deeper welds are produced when blunt electrodes (vertex angle 180 deg) are used. An explanation of the results, based on a literature survey, is included

  11. A singular perturbation limit of diffused interface energy with a fixed contact angle condition

    OpenAIRE

    Kagaya, Takashi; Tonegawa, Yoshihiro

    2016-01-01

    We study a general asymptotic behavior of critical points of a diffused interface energy with a fixed contact angle condition defined on a domain $\\Omega \\subset \\mathbb{R}^n$. We show that the limit varifold derived from the diffused energy satisfies a generalized contact angle condition on the boundary under a set of assumptions.

  12. Grounded running in quails: simulations indicate benefits of observed fixed aperture angle between legs before touch-down.

    Science.gov (United States)

    Andrada, Emanuel; Rode, Christian; Blickhan, Reinhard

    2013-10-21

    Many birds use grounded running (running without aerial phases) in a wide range of speeds. Contrary to walking and running, numerical investigations of this gait based on the BSLIP (bipedal spring loaded inverted pendulum) template are rare. To obtain template related parameters of quails (e.g. leg stiffness) we used x-ray cinematography combined with ground reaction force measurements of quail grounded running. Interestingly, with speed the quails did not adjust the swing leg's angle of attack with respect to the ground but adapted the angle between legs (which we termed aperture angle), and fixed it about 30ms before touchdown. In simulations with the BSLIP we compared this swing leg alignment policy with the fixed angle of attack with respect to the ground typically used in the literature. We found symmetric periodic grounded running in a simply connected subset comprising one third of the investigated parameter space. The fixed aperture angle strategy revealed improved local stability and surprising tolerance with respect to large perturbations. Starting with the periodic solutions, after step-down step-up or step-up step-down perturbations of 10% leg rest length, in the vast majority of cases the bipedal SLIP could accomplish at least 50 steps to fall. The fixed angle of attack strategy was not feasible. We propose that, in small animals in particular, grounded running may be a common gait that allows highly compliant systems to exploit energy storage without the necessity of quick changes in the locomotor program when facing perturbations. © 2013 Elsevier Ltd. All rights reserved.

  13. Biomechanical investigation of an alternative concept to angular stable plating using conventional fixation hardware

    Directory of Open Access Journals (Sweden)

    Radtke Roman

    2010-05-01

    Full Text Available Abstract Background Angle-stable locking plates have improved the surgical management of fractures. However, locking implants are costly and removal can be difficult. The aim of this in vitro study was to evaluate the biomechanical performance of a newly proposed crossed-screw concept ("Fence" utilizing conventional (non-locked implants in comparison to conventional LC-DCP (limited contact dynamic compression plate and LCP (locking compression plate stabilization, in a human cadaveric diaphyseal gap model. Methods In eight pairs of human cadaveric femora, one femur per pair was randomly assigned to receive a Fence construct with either elevated or non-elevated plate, while the contralateral femur received either an LCP or LC-DCP instrumentation. Fracture gap motion and fatigue performance under cyclic loading was evaluated successively in axial compression and in torsion. Results were statistically compared in a pairwise setting. Results The elevated Fence constructs allowed significantly higher gap motion compared to the LCP instrumentations (axial compression: p ≤ 0.011, torsion p ≤ 0.015 but revealed similar performance under cyclic loading (p = 0.43. The Fence instrumentation with established bone-plate contact revealed larger fracture gap motion under axial compression compared to the conventional LC-DCP osteosynthesis (p ≤ 0.017. However, all contact Fence specimens survived the cyclic test, whereas all LC-DCP constructs failed early during torsion testing (p Conclusions Even though accentuated fracture gap motion became obvious, the "Fence" technique is considered an alternative to cost-intensive locking-head devices. The concept can be of interest in cases were angle-stable implants are unavailable and can lead to new strategies in implant design.

  14. Osteosíntesis mini-invasiva con placas bloqueadas en fracturas metafisarias distales de tibia. Resultados clínico-funcionales. [Minimally invasive plate osteosynthesis in distal metaphyseal fractures of tibia. Comparison of results between fractures AO 43A and AO 43C.

    OpenAIRE

    Juan Manuel Yañez Arauz; Ignacio Arzac Ulla; Javier Del Vecchio; Andres Eksarho; Leandro Civetta; Rodrigo Perez Davila

    2015-01-01

    Introducción Las fracturas distales de tibia son un desafío para el tratamiento debido a la escasa cobertura y particular vascularización. Los objetivos del presente estudio son analizar los resultados clínicos y funcionales de los pacientes con fractura de tibia distal; tratados con técnica MIPO (minimally invasive plate osteosynthesis) con placas bloqueadas; comparar los resultados del grupo de fracturas tipo AO 43A con las tipo AO 43C1-C2; y comparar los resultados MIPO con el tratamie...

  15. A conjunct near-surface spectroscopy system for fix-angle and multi-angle continuous measurements of canopy reflectance and sun-induced chlorophyll fluorescence

    Science.gov (United States)

    Zhang, Qian; Fan, Yifeng; Zhang, Yongguang; Chou, Shuren; Ju, Weimin; Chen, Jing M.

    2016-09-01

    An automated spectroscopy system, which is divided into fix-angle and multi-angle subsystems, for collecting simultaneous, continuous and long-term measurements of canopy hyper-spectra in a crop ecosystem is developed. The fix-angle subsystem equips two spectrometers: one is HR2000+ (OceanOptics) covering the spectral range 200-1100 nm with 1.0 nm spectral resolution, and another one is QE65PRO (OceanOptics) providing 0.1 nm spectral resolution within the 730-780 nm spectral range. Both spectrometers connect a cosine-corrected fiber-optic fixed up-looking to collect the down-welling irradiance and a bare fiber-optic to measure the up-welling radiance from the vegetation. An inline fiber-optic shutter FOS-2x2-TTL (OceanOptics) is used to switch between input fibers to collect the signal from either the canopy or sky at one time. QE65PRO is used to permit estimation of vegetation Sun-Induced Fluorescence (SIF) in the O2-A band. The data collection scheme includes optimization of spectrometer integration time to maximize the signal to noise ratio and measurement of instrument dark currency. The multi-angle subsystem, which can help understanding bidirectional reflectance effects, alternatively use HR4000 (OceanOptics) providing 0.1 nm spectral resolution within the 680-800 nm spectral range to measure multi-angle SIF. This subsystem additionally includes a spectrometer Unispec-DC (PPSystems) featuring both up-welling and down-welling channels with 3 nm spectral resolution covering the 300-1100 nm spectral range. Two down-looking fiber-optics are mounted on a rotating device PTU-D46 (FLIR Systems), which can rotate horizontally and vertically at 10° angular step widths. Observations can be used to calculate canopy reflectance, vegetation indices and SIF for monitoring plant physiological processes.

  16. Light refraction in sapphire plates with a variable angle of crystal optical axis to the surface

    International Nuclear Information System (INIS)

    Vetrov, V. N.; Ignatenkov, B. A.

    2013-01-01

    The modification of sapphire by inhomogeneous plastic deformation makes it possible to obtain plates with a variable angle of inclination of the crystal optical axis to the plate surface. The refraction of light in this plate at perpendicular and oblique incidence of a parallel beam of rays is considered. The algorithm of calculating the refractive index of extraordinary ray and the birefringence is proposed.

  17. Bone Repair on Fractures Treated with Osteosynthesis, ir Laser, Bone Graft and Guided Bone Regeneration: Histomorfometric Study

    Science.gov (United States)

    dos Santos Aciole, Jouber Mateus; dos Santos Aciole, Gilberth Tadeu; Soares, Luiz Guilherme Pinheiro; Barbosa, Artur Felipe Santos; Santos, Jean Nunes; Pinheiro, Antonio Luiz Barbosa

    2011-08-01

    The aim of this study was to evaluate, through the analysis of histomorfometric, the repair of complete tibial fracture in rabbits fixed with osteosynthesis, treated or not with infrared laser light (λ780 nm, 50 mW, CW) associated or not to the use of hydroxyapatite and guided bone regeneration (GBR). Surgical fractures were created, under general anesthesia (Ketamina 0,4 ml/Kg IP and Xilazina 0,2 ml/Kg IP), on the dorsum of 15 Oryctolagus rabbits that were divided into 5 groups and maintained on individual cages, at day/night cycle, fed with solid laboratory pelted diet and had water ad libidum. On groups II, III, IV and V the fracture was fixed with wire osteosynthesis. Animals of groups III and V were grafted with hydroxyapatite and GBR technique used. Animals of groups IV and V were irradiated at every other day during two weeks (16 J/cm2, 4×4 J/cm2). Observation time was that of 30 days. After animal death (overdose of general anesthetics) the specimes were routinely processed to wax and underwent histological analysis by light microscopy. The histomorfometric analysis showed an increased bone neoformation, increased collagen deposition, less reabsorption and inflammation when laser was associated to the HATCP. It is concluded that IR laser light was able to accelerate fracture healing and the association with HATCP and GBR resulted on increased deposition of CHA.

  18. Fixation of zygomatic and mandibular fractures with biodegradable plates.

    Science.gov (United States)

    Degala, Saikrishna; Shetty, Sujeeth; Ramya, S

    2013-01-01

    In this prospective study, 13 randomly selected patients underwent treatment for zygomatic-complex fractures (2 site fractures) and mandibular fractures using 1.5 / 2 / 2.5-mm INION CPS biodegradable plates and screws. To assess the fixation of zygomatic-complex and mandibular fractures with biodegradable copolymer osteosynthesis system. In randomly selected 13 patients, zygomatic-complex and mandibular fractures were plated using resorbable plates and screws using Champy's principle. All the cases were evaluated clinically and radiologically for the type of fracture, need for the intermaxillary fixation (IMF) and its duration, duration of surgery, fixation at operation, state of reduction at operation, state of bone union after operation, anatomic reduction, paresthesia, occlusal discrepancies, soft tissue infection, immediate and late inflammatory reactions related to biodegradation process, and any need for the removal of the plates. Descriptives, Frequencies, and Chi-square test were used. In our study, the age group range was 5 to 55 years. Road traffic accidents accounted for the majority of patients six, (46.2%). Postoperative occlusal discrepancies were found in seven patients as mild to moderate, which resolved with IMF for 1-8 weeks. There were minimal complications seen and only as soft tissue infection. Use of biodegradable osteosynthesis system is a reliable alternative method for the fixation of zygomatic-complex and mandibular fractures. The biodegradable system still needs to be refined in material quality and handling to match the stability achieved with metal system. Biodegradable plates and screws is an ideal system for pediatric fractures with favorable outcome.

  19. Measurement of SEU thresholds and cross sections at fixed incidence angles

    International Nuclear Information System (INIS)

    Criswell, T.L.; Oberg, D.L.; Wert, J.L.; Measel, P.R.; Wilson, W.E.

    1987-01-01

    Current SEU testing and analysis techniques have as basic assumptions that the charge deposited at a junction depends linearly on the linear energy transfer (LET) of the ion and the pathlength of the ion through an imagined parallelepiped that represents the depletion region. This study tests these assumptions for two bipolar parts, AMD 27LS00 and Fairchild 93L422, by irradiating at fixed angles while varying the LET of two ion species. It was found that the 27LS00 shows a pronounced ion species dependence, and may show a deviation of deposited charge from the usual inverse-cosine times a fixed depletion depth, while the 93L422 exhibited the expected inverse-cosine dependence and no ion species dependence

  20. A customized fixation plate with novel structure designed by topological optimization for mandibular angle fracture based on finite element analysis.

    Science.gov (United States)

    Liu, Yun-Feng; Fan, Ying-Ying; Jiang, Xian-Feng; Baur, Dale A

    2017-11-15

    The purpose of this study was to design a customized fixation plate for mandibular angle fracture using topological optimization based on the biomechanical properties of the two conventional fixation systems, and compare the results of stress, strain and displacement distributions calculated by finite element analysis (FEA). A three-dimensional (3D) virtual mandible was reconstructed from CT images with a mimic angle fracture and a 1 mm gap between two bone segments, and then a FEA model, including volume mesh with inhomogeneous bone material properties, three loading conditions and constraints (muscles and condyles), was created to design a customized plate using topological optimization method, then the shape of the plate was referenced from the stress concentrated area on an initial part created from thickened bone surface for optimal calculation, and then the plate was formulated as "V" pattern according to dimensions of standard mini-plate finally. To compare the biomechanical behavior of the "V" plate and other conventional mini-plates for angle fracture fixation, two conventional fixation systems were used: type A, one standard mini-plate, and type B, two standard mini-plates, and the stress, strain and displacement distributions within the three fixation systems were compared and discussed. The stress, strain and displacement distributions to the angle fractured mandible with three different fixation modalities were collected, respectively, and the maximum stress for each model emerged at the mandibular ramus or screw holes. Under the same loading conditions, the maximum stress on the customized fixation system decreased 74.3, 75.6 and 70.6% compared to type A, and 34.9, 34.1, and 39.6% compared to type B. All maximum von Mises stresses of mandible were well below the allowable stress of human bone, as well as maximum principal strain. And the displacement diagram of bony segments indicated the effect of treatment with different fixation systems. The

  1. Deflection and trapping of a counter-rotating vortex pair by a flat plate

    Science.gov (United States)

    Nitsche, Monika

    2017-12-01

    The interaction of a counter-rotating vortex pair (dipole) with a flat plate in its path is studied numerically. The vortices are initially separated by a distance D (dipole size) and placed far upstream of a plate of length L . The plate is centered on the dipole path and inclined relative to it at an incident angle βi. At first, the plate is held fixed in place. The vortices approach the plate, travel around it, and then leave as a dipole with unchanged velocity but generally a different travel direction, measured by a transmitted angle βt. For certain plate angles the transmitted angle is highly sensitive to changes in the incident angle. The sensitivity increases as the dipole size decreases relative to the plate length. In fact, for sufficiently small values of D /L , singularities appear: near critical values of βi, the dipole trajectory undergoes a topological discontinuity under changes of βi or D /L . The discontinuity is characterized by a jump in the winding number of one vortex around the plate, and in the time that the vortices take to leave the plate. The jumps occur repeatedly in a self-similar, fractal fashion, within a region near the critical values of βi, showing the existence of incident angles that trap the vortices, which never leave the plate. The number of these trapping regions increases as the parameter D /L decreases, and the dependence of the motion on βi becomes increasingly complex. The simulations thus show that even in this apparently simple scenario, the inviscid dynamics of a two-point-vortex system interacting with a stationary wall is surprisingly rich. The results are then applied to separate an incoming stream of dipoles by an oscillating plate.

  2. Effectiveness of Variable-Gain Kalman Filter Based on Angle Error Calculated from Acceleration Signals in Lower Limb Angle Measurement with Inertial Sensors

    Science.gov (United States)

    Watanabe, Takashi

    2013-01-01

    The wearable sensor system developed by our group, which measured lower limb angles using Kalman-filtering-based method, was suggested to be useful in evaluation of gait function for rehabilitation support. However, it was expected to reduce variations of measurement errors. In this paper, a variable-Kalman-gain method based on angle error that was calculated from acceleration signals was proposed to improve measurement accuracy. The proposed method was tested comparing to fixed-gain Kalman filter and a variable-Kalman-gain method that was based on acceleration magnitude used in previous studies. First, in angle measurement in treadmill walking, the proposed method measured lower limb angles with the highest measurement accuracy and improved significantly foot inclination angle measurement, while it improved slightly shank and thigh inclination angles. The variable-gain method based on acceleration magnitude was not effective for our Kalman filter system. Then, in angle measurement of a rigid body model, it was shown that the proposed method had measurement accuracy similar to or higher than results seen in other studies that used markers of camera-based motion measurement system fixing on a rigid plate together with a sensor or on the sensor directly. The proposed method was found to be effective in angle measurement with inertial sensors. PMID:24282442

  3. Management of pediatric mandibular fractures using bioresorbable plating system - Efficacy, stability, and clinical outcomes: Our experiences and literature review.

    Science.gov (United States)

    Singh, Mahinder; Singh, R K; Passi, Deepak; Aggarwal, Mohit; Kaur, Guneet

    2016-01-01

    The purpose of this study was to determine the efficacy and stability of the biodegradable fixation system for treatment of mandible fractures in pediatric patients by measuring the bite force. Sixty pediatric patients with mandibular fractures (36 males, 24 females) were included in this study. The 2.5-mm resorbable plates were adapted along Champy's line of ideal osteosynthesis and secured with four 2.5 mm diameter monocortical resorbable screws, 8 mm in length. All patients were followed for 10 months. Clinical parameters, such as soft tissue infection, nonunion, malunion, implant exposure, malocclusion, nerve injury, and bite force for stability, were prospectively assessed. Adequate fixation and primary bone healing was achieved in 100% of the cases. Six minor complications (10%) were observed: 2 soft tissue infections (3%), 1 plate dehiscence (2%), 1 malocclusion (2%), and 2 paresthesia (3%). 2.5-mm resorbable plating system along Champy's line of ideal osteosynthesis is a good treatment modality for mandible fractures in pediatric patients.

  4. Large-amplitude and narrow-band vibration phenomenon of a foursquare fix-supported flexible plate in a rigid narrow channel

    Energy Technology Data Exchange (ETDEWEB)

    Liu Lifang, E-mail: liu_lifang1106@yahoo.cn [School of Nuclear Science and Engineering, North China Electric Power University, Zhuxinzhuang, Dewai, Beijing 102206 (China); Lu Daogang, E-mail: ludaogang@ncepu.edu.cn [School of Nuclear Science and Engineering, North China Electric Power University, Zhuxinzhuang, Dewai, Beijing 102206 (China); Li Yang, E-mail: qinxiuyi@sina.com [School of Nuclear Science and Engineering, North China Electric Power University, Zhuxinzhuang, Dewai, Beijing 102206 (China); Zhang Pan, E-mail: zhangpan@ncepu.edu.cn [School of Nuclear Science and Engineering, North China Electric Power University, Zhuxinzhuang, Dewai, Beijing 102206 (China); Niu Fenglei, E-mail: niufenglei@ncepu.edu.cn [School of Nuclear Science and Engineering, North China Electric Power University, Zhuxinzhuang, Dewai, Beijing 102206 (China)

    2011-08-15

    Highlights: > FIV of a foursquare fix-supported flexible plate exposed to axial flow was studied. > Special designed test section and advanced measuring equipments were adopted. > The narrow-band vibration phenomenon with large amplitude was observed. > Line of plate's vibration amplitude and flow rate was investigated. > The phenomenon and the measurement error were analyzed. - Abstract: An experiment was performed to analyze the flow-induced vibration behavior of a foursquare fix-supported flexible plate exposed to the axial flow within a rigid narrow channel. The large-amplitude and narrow-band vibration phenomenon was observed in the experiment when the flow velocity varied with the range of 0-5 m/s. The occurring condition and some characteristics of the large-amplitude and narrow-band vibrations were investigated.

  5. The power flow angle of acoustic waves in thin piezoelectric plates.

    Science.gov (United States)

    Kuznetsova, Iren E; Zaitsev, Boris D; Teplykh, Andrei A; Joshi, Shrinivas G; Kuznetsova, Anastasia S

    2008-09-01

    The curves of slowness and power flow angle (PFA) of quasi-antisymmetric (A(0)) and quasi-symmetric (S(0)) Lamb waves as well as quasi-shear-horizontal (SH(0)) acoustic waves in thin plates of lithium niobate and potassium niobate of X-,Y-, and Z-cuts for various propagation directions and the influence of electrical shorting of one plate surface on these curves and PFA have been theoretically investigated. It has been found that the group velocity of such waves does not coincide with the phase velocity for the most directions of propagation. It has been also shown that S(0) and SH(0) wave are characterized by record high values of PFA and its change due to electrical shorting of the plate surface in comparison with surface and bulk acoustic waves in the same material. The most interesting results have been verified by experiment. As a whole, the results obtained may be useful for development of various devices for signal processing, for example, electrically controlled acoustic switchers.

  6. Predictive factors for functional outcome and failure in angular stable osteosynthesis of the proximal humerus.

    LENUS (Irish Health Repository)

    Hardeman, Francois

    2012-02-01

    Angular stable osteosynthesis has become the gold standard in the operative treatment of proximal humeral fractures. The aim of this article is to determine the indications for osteosynthesis versus primary arthroplasty based on clinical and radiological parameters.

  7. Displaced proximal humeral fractures: an Indian experience with locking plates

    Directory of Open Access Journals (Sweden)

    Aggarwal Sameer

    2010-08-01

    Full Text Available Abstract Background The treatment of displaced proximal humerus fractures, especially in elderly, remains controversial. The objective of this study was to evaluate functional outcome of locking plate used for fixation of these fractures after open reduction. We also attempted to evaluate the complications and predictors of loss of fixation for such an implant. Methods Over two and a half years, 56 patients with an acute proximal humerus fracture were managed with locking plate osteosynthesis. 47 of these patients who completed a minimum follow up of 1 year were evaluated using Constant score calculation. Statistical analysis was done using SPSS 16 and a p value of less than 0.05 was taken as statistically significant. Results The average follow up period was around 21.5 months. Outcomes were excellent in 17%, good in 38.5%, moderate in 34% while poor in 10.5%. The Constant score was poorer for AO-OTA type 3 fractures as compared to other types. The scores were also inferior for older patients (> 65 years old. Complications included screw perforation of head, AVN, subacromial impingement, loss of fixation, axillary nerve palsy and infection. A varus malalignment was found to be a strong predictor of loss of fixation. Conclusion Locking plate osteosynthesis leads to satisfactory functional outcomes in all the patients. Results are better than non locking plates in osteoporotic fractures of the elderly. However the surgery has steep learning curve and various complications could be associated with its use. Nevertheless we believe that a strict adherence to the principles of locking plate use can ensure good result in such challenging fractures.

  8. Osteosynthesis of a periprosthetic fracture of the proximal femur with the distal femur LISS system

    DEFF Research Database (Denmark)

    Tarnowski, Jan Robert; Holck, Kim

    2008-01-01

    In this case report, we show how it is possible to perform osteosynthesis using minimal invasive techniques instead of conventional methods. In this instance the osteosynthesis was performed on a patient in poor general condition who had presented a periprosthetic fracture of the proximal femur. ...

  9. [Close reduction combined with minimally invasive percutaneous plate osteosynthesis for proximal and distal tibial fractures: a report of 56 patients].

    Science.gov (United States)

    Liu, Yin-Wen; Kuang, Yong; Gu, Xin-Feng; Zheng, Yu-Xin; Li, Zhi-Qiang; Wei, Xiao-En; Zhang, Ming-Cai; Zhan, Hong-Sheng; Shi, Yin-yu

    2013-03-01

    To evaluate the clinical effects of close reduction combined with minimally invasive percutanous plate osteosynthesis (MIPPO) for proximal and distal tibial fractures. From March 2007 to December 2010, 56 patients with proximal and distal tibial fractures were treated with close reduction combined with MIPPO technique. There were 39 males and 17 females,aged from 22 to 67 years with an average of 41.3 years. Left fracture was in 25 cases and right fracture was in 31 cases; proximal tibial fracture was in 15 cases and distal tibial fractures was in 41 cases; 34 cases caused by fall down and 22 cases caused by road accident. The mean time from injury to operation was 1.7 d. Clinical manifestation included pain, swelling of leg with limitation of activity. According to the standard of Johner-Wruhs, clinical effects were evaluated. The mean operative time was 46 min in 56 patients. All fractures obtained satisfactory reduction and the location of plate was good. Incisions healed with one-stage and no superficial or deep infection was found. All the patients were followed up from 8 to 23 months with an average of 14.2 months. Only one fracture complication with delayed union,and after auto grafting with ilium bone,the fracture got union. Other 55 cases obtained bone healing in 15 to 20 weeks after operation and no internal fixation failure was found. The time of walking was 4-6 months after operation,without limping at 7 months after operation. Both lower extremities were symmetrical and the function of knee and ankle got complete recovery. According to the criteria of Johner-Wruhs score,46 cases obtained excellent results,9 good and 2 fair. Treatment of proximal and distal tibial fractures with close reduction and MIPPO technique can not only preserve soft tissue,simplify operative procedure and decrease wound, but also can obtain rigid internal fixation and guarantee early function exercises of knee and ankle joints. The method has the advantages of less soft tissue

  10. [Development of polyaxial locking plate screw system of sacroiliac joint].

    Science.gov (United States)

    Fan, Weijie; Xie, Xuesong; Zhou, Shuping; Zhang, Yonghu

    2014-09-01

    To develop an instrument for sacroiliac joint fixation with less injury and less complications. Firstly, 18 adult pelvic specimens (8 males and 10 females) were used to measure the anatomical data related to the locking plates and locking screws on the sacrum and ilium, and the polyaxial locking plate screw system of the sacroiliac joint was designed according to the anatomic data. This system was made of medical titanium alloy. Then 4 adult male plevic specimens were harvested and the experiment was divided into 3 groups: group A (normal pelvic), group B (the dislocated sacroiliac joint fixed with sacroiliac screws), and group C (the dislocated sacroiliac joint fixed with polyaxial locking plate screw system). The vertical displacement of sacroiliac joint under the condition of 0-700 N vertical load and the horizontal displacement on angle under the condition of 0-12 N·m torsional load were compared among the 3 groups by using the biological material test system. Finally, the simulated application test was performed on 1 adult male cadaveric specimen to observe soft tissue injury and the position of the locking plate and screw by X-ray films. According to the anatomic data of the sacrum and ilium, the polyaxial locking plate screw system of the sacroiliac joint was designed. The biomechanical results showed that the vertical displacement of the sacroiliac joint under the condition of 0-700 N vertical load in group A was significantly bigger than that in group B and group C (P 0.05). The horizontal displacement on angle under the condition of 0-12 N·m torsional load in group A was significantly less than that in group B and group C (P 0.05). The test of simulating application showed that the specimen suffered less soft tissue injury, and this instrument could be implanted precisely and safely. The polyaxial locking plate screw system of the sacroiliac joint has the advantages of smaller volume and less injury; polyaxial fixation enables flexible adjustment screw

  11. Osteosynthesis of the diaphysis of the humeral with plates - Series of cases

    International Nuclear Information System (INIS)

    Reyes Reyes, Claudia Juliana; Valencia Chamorro, Martha Patricia; Garcia Gonzalez, Luis Alejandro

    2005-01-01

    Humeral shaft fractures may be treated in various ways. When surgical treatment is preferred, both plates and intramedullary nails are available and feasible options; the latter have recently gained popularity. We present the results of a case series of humeral fractures treated by open reduction and plate fixation with DCP plates, the results are described in terms of union rate, function, satisfaction, and complications. Thirty patients were included, with ages from 18 to 74 years, with mean follow-up time of 35 months; twelve patients were treated for delayed or non-union after orthopedic treatment. There was one case of nonunion, and one of iatrogenic neurapraxia of the radial nerve. Mobility and strength were excellent. All patients reported to be satisfied with the treatment and its result. We discuss that plate fixation for humeral shaft fractures is a predictable choice, with low complication rate and high union rate

  12. The role of minimally invasive plate osteosynthesis in rib fixation : A review

    NARCIS (Netherlands)

    Bemelman, Michael; Van Baal, Mark; Yuan, Jian Zhang; Leenen, Luke

    2016-01-01

    More than a century ago, the first scientific report was published about fracture fixation with plates. During the 1950's, open reduction and plate fixation for fractures were standardized by the founders of Arbeitsgemeinschaft für osteosynthesefragen/Association for the Study of Internal Fixation.

  13. Degradable polymeric materials for osteosynthesis: Tutorial

    Directory of Open Access Journals (Sweden)

    D Eglin

    2008-12-01

    Full Text Available This report summarizes the state of the art and recent developments and advances in the use of degradable polymers devices for osteosynthesis. The current generation of biodegradable polymeric implants for bone repair utilising designs copied from metal implants, originates from the concept that devices should be supportive and as “inert” substitute to bone tissue. Today degradable polymeric devices for osteosynthesis are successful in low or mild load bearing applications. However, the lack of carefully controlled randomized prospective trials that document their efficacy in treating a particular fracture pattern is still an issue. Then, the choice between degradable and non-degradable devices must be carefully weighed and depends on many factors such as the patient age and condition, the type of fracture, the risk of infection, etc. The improvement of the biodegradable devices mechanical properties and their degradation behaviour will have to be achieved to broaden their use. The next generation of biodegradable implants will probably see the implementation of the recent gained knowledge in cell-material interactions and cells therapy, with a better control of the spatial and temporal interfaces between the material and the surrounding bone tissue.

  14. Standardization of the CFU-GM assay: Advantages of plating a fixed number of CD34+ cells in collagen gels.

    Science.gov (United States)

    Dobo, Irène; Pineau, Danielle; Robillard, Nelly; Geneviève, Frank; Piard, Nicole; Zandecki, Marc; Hermouet, Sylvie

    2003-10-01

    We investigated whether plating a stable amount of CD34(+) cells improves the CFU-GM assay. Data of CFU-GM assays performed with leukaphereses products in two transplant centers using a commercial collagen-based medium and unified CFU-GM scoring criteria were pooled and analyzed according to the numbers of CD34(+) cells plated. A first series of 113 CFU-GM assays was performed with a fixed number of mononuclear cells (i.e., a variable number of CD34(+) cells). In these cultures the CFU-GM/CD34 ratio varied according to the number of CD34(+) cells plated: median CFUGM/CD34 ratios were 1/6.2 to 1/6.6 for grafts containing or =2% CD34(+) cells. The median CFU-GM/CD34 ratio also varied depending on pathology: 1/9.3 for multiple myeloma (MM), 1/6.8 for Hodgkin's disease (HD), 1/6.5 for non-Hodgkin lymphoma (NHL), and 1/4.5 for solid tumors (ST). A second series of 95 CFU-GM assays was performed with a fixed number of CD34(+) cells (220/ml). The range of median CFU-GM/CD34 ratios was narrowed to 1/7.0 to 1/5.2, and coefficients of variation for CFU-GM counts decreased by half to 38.1% (NHL), 36.1% (MM), 49.9% (HD), and 22.4% (ST). In addition, CFU-GM scoring was facilitated as the percentages of cultures with >50 CFU/GM/ml decreased from 6.7% to 43.8% when a variable number of CD34(+) cells was plated, to 4.5% to 16.7% when 220 CD34(+) cells/ml were plated. Hence, plating a fixed number of CD34(+) cells in collagen gels improves the CFU-GM assay by eliminating cell number-related variability and reducing pathology-related variability in colony growth.

  15. Real-Time Vehicle Speed Estimation Based on License Plate Tracking in Monocular Video Sequences

    Directory of Open Access Journals (Sweden)

    Aleksej MAKAROV

    2016-02-01

    Full Text Available A method of estimating the vehicle speed from images obtained by a fixed over-the-road monocular camera is presented. The method is based on detecting and tracking vehicle license plates. The contrast between the license plate and its surroundings is enhanced using infrared light emitting diodes and infrared camera filters. A range of the license plate height values is assumed a priori. The camera vertical angle of view is measured prior to installation. The camera tilt is continuously measured by a micro-electromechanical sensor. The distance of the license plate from the camera is theoretically derived in terms of its pixel coordinates. Inaccuracies due to the frame rate drift, to the tilt and the angle of view measurement errors, to edge pixel detection and to a coarse assumption of the vehicle license plate height are analyzed and theoretically formulated. The resulting system is computationally efficient, inexpensive and easy to install and maintain along with the existing ALPR cameras.

  16. COMPUTER-AIDED OPTIMIZATION OF CHOICE AND POSITIONING OF BONE PLATES AND SCREWS USED FOR INTERNAL-FIXATION OF MANDIBULAR FRACTURES

    NARCIS (Netherlands)

    ROZEMA, FR; BOS, RRM; BOERING, G; VANWILLIGEN, JD

    1992-01-01

    The present study describes a biomechanical integrated model of the mandibular system in which the maxilla and mandible, the masticatory muscles, and the temporomandibular joints are regarded as one system. In this model, strains in plate-osteosynthesis devices for internal fixation of mandibular

  17. Management of pediatric mandibular fractures using bioresorbable plating system – Efficacy, stability, and clinical outcomes: Our experiences and literature review

    Science.gov (United States)

    Singh, Mahinder; Singh, R.K.; Passi, Deepak; Aggarwal, Mohit; Kaur, Guneet

    2015-01-01

    Aims The purpose of this study was to determine the efficacy and stability of the biodegradable fixation system for treatment of mandible fractures in pediatric patients by measuring the bite force. Methods Sixty pediatric patients with mandibular fractures (36 males, 24 females) were included in this study. The 2.5-mm resorbable plates were adapted along Champy's line of ideal osteosynthesis and secured with four 2.5 mm diameter monocortical resorbable screws, 8 mm in length. All patients were followed for 10 months. Clinical parameters, such as soft tissue infection, nonunion, malunion, implant exposure, malocclusion, nerve injury, and bite force for stability, were prospectively assessed. Results Adequate fixation and primary bone healing was achieved in 100% of the cases. Six minor complications (10%) were observed: 2 soft tissue infections (3%), 1 plate dehiscence (2%), 1 malocclusion (2%), and 2 paresthesia (3%). Conclusion 2.5-mm resorbable plating system along Champy's line of ideal osteosynthesis is a good treatment modality for mandible fractures in pediatric patients. PMID:27195206

  18. Minimally invasive percutaneous plate fixation of distal tibia fractures.

    LENUS (Irish Health Repository)

    Bahari, Syah

    2007-10-01

    We report a series of 42 patients reviewed at a mean of 19.6 months after treatment of distal tibial and pilon fractures using the AO distal tibia locking plate with a minimally invasive percutaneous plate osteosynthesis (MIPPO) technique. Mean time to union was 22.4 weeks. All fractures united with acceptable alignment and angulation. Two cases of superficial infection were noted, with one case of deep infection. Mean SF36 score was 85 and mean AOFAS score was 90 at a mean of 19 months follow-up. We report satisfactory outcomes with the use of the AO distal tibia locking plate in treatment of unstable distal tibial fractures. Eighty-nine percent of the patients felt that they were back to their pre injury status and 95% back to their previous employment.

  19. Plate fixation for proximal chevron osteotomy has greater risk for hallux valgus recurrence than Kirschner wire fixation.

    Science.gov (United States)

    Park, Chul-Hyun; Ahn, Ji-Yong; Kim, Yu-Mi; Lee, Woo-Chun

    2013-06-01

    The purpose of this study was to compare the results of hallux valgus surgery between feet fixed with Kirschner wires and those fixed with a plate and screws. Between December 2008 and November 2009, 53 patients (62 feet) were treated with proximal chevron osteotomy and distal soft tissue procedure for symptomatic moderate to severe hallux valgus deformity. Thirty-four patients (41 feet) were stabilised with Kirschner wires (K-wire group) and 19 patients (21 feet) were stabilised with a locking plate (plate group). Clinical results were assessed using American Orthopaedic Foot and Ankle Society (AOFAS) score. Radiographic parameters were compared between these groups. Recurrence rate at the last follow-up was compared between the K-wire and plate groups. Mean AOFAS score was lower in the plate group, however, the difference between the groups was not statistically significant in AOFAS score at the last follow-up. Hallux valgus angle and intermetatarsal angle were significantly larger in the plate group at the last follow-up. Mean 1-2 metatarsal (MT) distance on immediately postoperative radiographs was significant larger in the plate group. Four (9.8 %) of the 41 feet in the K-wire group and 7 (33.3 %) of the 21 feet in the plate group showed hallux valgus recurrence at the last follow-up. The plate group had a significantly higher risk of recurrence than the K-wire group. Fixation of proximal chevron osteotomy using a plate and screws has a greater risk of hallux valgus recurrence than fixation using Kirschner wires.

  20. Implant Material, Type of Fixation at the Shaft, and Position of Plate Modify Biomechanics of Distal Femur Plate Osteosynthesis.

    Science.gov (United States)

    Kandemir, Utku; Augat, Peter; Konowalczyk, Stefanie; Wipf, Felix; von Oldenburg, Geert; Schmidt, Ulf

    2017-08-01

    To investigate whether (1) the type of fixation at the shaft (hybrid vs. locking), (2) the position of the plate (offset vs. contact) and (3) the implant material has a significant effect on (a) construct stiffness and (b) fatigue life in a distal femur extraarticular comminuted fracture model using the same design of distal femur periarticular locking plate. An extraarticular severely comminuted distal femoral fracture pattern (OTA/AO 33-A3) was simulated using artificial bone substitutes. Ten-hole distal lateral femur locking plates were used for fixation per the recommended surgical technique. At the distal metaphyseal fragment, all possible locking screws were placed. For the proximal diaphyseal fragment, different types of screws were used to create 4 different fixation constructs: (1) stainless steel hybrid (SSH), (2) stainless steel locked (SSL), (3) titanium locked (TiL), and (4) stainless steel locked with 5-mm offset at the diaphysis (SSLO). Six specimens of each construct configuration were tested. First, each specimen was nondestructively loaded axially to determine the stiffness. Then, each specimen was cyclically loaded with increasing load levels until failure. Construct Stiffness: The fixation construct with a stainless steel plate and hybrid fixation (SSH) had the highest stiffness followed by the construct with a stainless steel plate and locking screws (SSL) and were not statistically different from each other. Offset placement (SSLO) and using a titanium implant (TiL) significantly reduced construct stiffness. Fatigue Failure: The stainless steel with hybrid fixation group (SSH) withstood the most number of cycles to failure and higher loads, followed by the stainless steel plate and locking screw group (SSL), stainless steel plate with locking screws and offset group (SSLO), and the titanium plate and locking screws group (TiL) consecutively. Offset placement (SSLO) as well as using a titanium implant (TiL) reduced cycles to failure. Using the

  1. History of internal fixation with plates (part 2): new developments after World War II; compressing plates and locked plates.

    Science.gov (United States)

    Hernigou, Philippe; Pariat, Jacques

    2017-07-01

    The first techniques of operative fracture with plates were developed in the 19th century. In fact, at the beginning these methods consisted of an open reduction of the fracture usually followed by a very unstable fixation. As a consequence, the fracture had to be opened with a real risk of (sometimes lethal) infection, and due to unstable fixation, protection with a cast was often necessary. During the period between World Wars I and II, plates for fracture fixation developed with great variety. It became increasingly recognised that, because a fracture of a long bone normally heals with minimal resorption at the bone ends, this may result in slight shortening and collapse, so a very rigid plate might prevent such collapse. However, as a consequence, delayed healing was observed unless the patient was lucky enough to have the plate break. One way of dealing with this was to use a slotted plate in which the screws could move axially, but the really important advance was recognition of the role of compression. After the first description of compression by Danis with a "coapteur", Bagby and Müller with the AO improved the technique of compression. The classic dynamic compression plates from the 1970s were the key to a very rigid fixation, leading to primary bone healing. Nevertheless, the use of strong plates resulted in delayed union and the osteoporosis, cancellous bone, comminution, and/or pathological bone resulted in some failures due to insufficient stability. Finally, new devices represented by locking plates increased the stability, contributing to the principles of a more biological osteosynthesis while giving enough stability to allow immediate full weight bearing in some patients.

  2. Operative treatment of intra-articular calcaneal fractures with calcaneal plates and its complications

    Directory of Open Access Journals (Sweden)

    Rak Vaclav

    2009-01-01

    Full Text Available Background: In a retrospective study we analysed intra-articular calcaneal fracture treatment by comparing results and complications related to fracture stabilization with nonlocking calcaneal plates and locking compression plates. Materials and Methods: We performed 76 osteosynthesis (67 patients of intra-articular calcaneal fractures using the standard extended lateral approach from February 2004 to October 2007. Forty-two operations using nonlocking calcaneal plates (group A were performed during the first three years, and 34 calcaneal fractures were stabilized using locking compression plates (group B in 2007. In the Sanders type IV fractures, reconstruction of the calcaneal shape was attempted. Depending on the type of late complication, we performed subtalar arthroscopy in six cases, arthroscopically assisted subtalar distraction bone block arthrodesis in six cases, and plate removal with lateral-wall decompression in five cases. The patients were evaluated by the AOFAS Ankle-Hindfoot Scale. Results: Wound healing complications were 7/42 (17% in group A and 1/34 (3% in group B. No patient had deep osseous infection or foot rebound compartment syndrome. Preoperative size of Bφhler´s angle correlated with postoperative clinical results in both groups. There were no late complications necessitating corrective procedure or arthroscopy until December 2008 in Group B. All late complications ccurred in Group A. The overall results according to the AOFAS Ankle Hindfoot Scale were good or excellent in 23/42 (55% in group A and in 30/34 (85% in group B. Conclusion: Open reduction and internal fixation of intra-articular calcaneal fractures has become a standard surgical method. Fewer complications and better results related to treatment with locking compression plates confirmed in comparison to nonlocking ones were noted for all Sanders types of intra-articular calcaneal fractures. Age and Sanders type IV fractures are not considered to be the

  3. Osteoarthritis after osteosynthesis of ankle injuries

    International Nuclear Information System (INIS)

    Lange, S.; Mechsner, K.; Langenscheidt, P.; Krankenhaus Spandau, Berlin

    1984-01-01

    98 patients were clinically and radiographically examined 2 to 9 years following the osteosynthesis of ankle fractures. The rate of secondary osteoarthritis was 70% including 40% of minor, 17% of medium and 13% of serious changes. Depending on the injured structures the frequency of posttraumatic osteoarthritis varies. Medium and serious radiology changes cause obvious dysfunction in 56% and 62% respectively. Joints free of Osteoarthritis one year after the injury will not develop secondary osteoarthritis later. (orig.) [de

  4. Treatment Results Of Diaphyseal Forearm Fractures With Dynamique Compression Plate A Retrospective study of 156 Cases.

    Directory of Open Access Journals (Sweden)

    Hassan BOUSSAKRI

    2015-12-01

    Full Text Available This retrospective study addresses a series of 156 cases of forearm fractures. These 156 cases were managed in the trauma-orthopedic department (B4 of Fez University Hospital, Morocco, from May 2008 till January 2013. The purpose of this study is to analyze epidemiological and clinical factors of diaphyseal forearm fractures and the results of their treatment with dynamic compression plate (DCP, as well as the complications and therapeutic errors of this surgical technique. The frequency of hospitalization in the trauma-orthopedic department was 3,96%. Ages ranged between 16 and 83, the average age was 32. 132 patients were male (85%. 90% were managed at the day of trauma. Traffic accidents were the most frequent cause in 52% patients. The fracture was in the left forearm in 65% of patients. 53% of fracture lines were in the middle third of the forearm. 38 fractures were open, and 30 were admitted for polytrauma. Osteosynthesis was performed with dynamic compression plate for all patients. In comparison with the literature, our series shows the predominance of young male patients, with traffic accidents being the cause. Osteosynthesis with dynamic compression plate remains the treatment of choice that provides satisfactory results if the accuracy in this technique was respected.

  5. Locking plate fixation in distal metaphyseal tibial fractures: series of 79 patients

    OpenAIRE

    Gupta, Rakesh K.; Rohilla, Rajesh Kumar; Sangwan, Kapil; Singh, Vijendra; Walia, Saurav

    2009-01-01

    Open reduction and internal fixation in distal tibial fractures jeopardises fracture fragment vascularity and often results in soft tissue complications. Minimally invasive osteosynthesis, if possible, offers the best possible option as it permits adequate fixation in a biological manner. Seventy-nine consecutive adult patients with distal tibial fractures, including one patient with a bilateral fracture of the distal tibia, treated with locking plates, were retrospectively reviewed. The 4.5-...

  6. The anterior tilt angle of the proximal tibia epiphyseal plate: a significant radiological finding in young children with trampoline fractures.

    Science.gov (United States)

    Stranzinger, Enno; Leidolt, Lars; Eich, Georg; Klimek, Peter Michael

    2014-08-01

    Evaluation of the anterior tilt angle of the proximal tibia epiphyseal plate in young children, which suffered a trampoline fracture in comparison with a normal population. 62 children (31 females, 31 males) between 2 and 5 years of age (average 2 years 11 months, standard deviation 11 months) with radiographs in two views of the tibia were included in this retrospective study. 25 children with proximal tibia fractures were injured with a history of jumping on a trampoline. All other causes for tibia fractures were excluded. A normal age-mapped control cohort of 37 children was compared. These children had neither evidence of a trampoline related injury nor a fracture of the tibia. The anterior tilt angle of the epiphyseal plate of the tibia was defined as an angle between the proximal tibia physis and the distal tibia physis on a lateral view. Two radiologists evaluated all radiographs for fractures and measured the anterior tilt angle in consensus. An unpaired Student's t-test was used for statistical analysis (SPSS). Original reports were reviewed and compared with the radiological findings and follow-up radiographs. In the normal control group, the average anterior tilt angle measured -3.2°, SD ± 2.8°. The children with trampoline fractures showed an anterior tilt of +4.4°, SD ± 2.9°. The difference was statistically significant, Ptrampoline. These fractures may be very subtle and difficult to detect on initial radiographs. Measurement of the anterior tilt angle of the proximal tibia epiphyseal plate on lateral radiographs is supportive for interpreting correctly trampoline fractures. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  7. [TRANSOSSEOUS OSTEOSYNTHESIS OF LOWER EXTREMITIES BONES FRACTURES AND QUALITY OF LIFE OF PATIENTS IN THE TREATMENT PERIOD].

    Science.gov (United States)

    Dyusupov, A; Dyusupov, A; Manarbekov, E; Bukatov, A; Serikbaev, A

    2018-02-01

    The aim of the study is a comparative analysis of the quality of life in the treatment of fractures of the bones of the lower extremities of various localizations using transosseous and submerged osteosynthesis. We examined 397 patients with injuries of the lower segment of the lower extremity (patellar fractures - 81, multiple bones fractures of the tibia - 84 and fractures of the ankles, accompanied by a dislocation of the foot - 232). Patients were distributed in the subgroups depending on the treatment. The main group was performed using transosseous osteosynthesis, the comparison group - submerged osteosynthesis. The quality of life was examined using a general questionnaire SF-36 and specialized KOOS (with patella fractures) and FOAS (fractures of the bones of the lower leg and ankles). In patients with all localizations of fractures the quality of life was exceeded in the subgroups of the transosseous osteosynthesis group over the parameters of the comparison group. The most significant differences with the use of specialized questionnaires were revealed 6-9 months after trauma with a tendency to leveling to the end of the study (1 year). A more pronounced excess of the quality of life in the main group was seen in fractures of the shin bones. The study of the quality of life allows us to recommend the use of transosseous osteosynthesis for the treatment of lower segment of the lower limb bone fractures.

  8. Comparative evaluation of 2.3 mm locking plate system vs conventional 2.0 mm non locking plate system for mandibular condyle fracture fixation: a seven year retrospective study.

    Science.gov (United States)

    Zhang, J; Wang, X; Wu, R-H; Zhuang, Q-W; Gu, Q P; Meng, J

    2015-01-01

    This retrospective study evaluated the efficacy of a 2.3 mm locking plate/screw system compared with a 2.0-mm non-locking plate/screw system in fixation of isolated non comminuted mandibular condyle fractures. Surgical records of 101 patients who received either a 2.3 mm locking plate (group A, n = 51) or 2.0 mm non locking plate (group B, n = 50) were analyzed. All patients were followed up to a minimum of 6 months postoperatively and evaluated for hardware related complications, occlusal stability, need for and duration of MMF and mandibular functional results. Four complications occurred in the locking group and eighteen in the non locking group with complication rates equalling 8% and 36% respectively. When comparing the overall results according to plates used, the χ2 test showed a statistically significant difference between the locking and non locking plates (p Mandibular condyle fractures treated with a 2.3 mm locking plate exhibited stable osteosynthesis, were associated with minimal complications and resulted in acceptable mandibular range of motion compared with a 2.0 mm non locking plate.

  9. OSTEOSYNTHESIS OF THE SPINE AT PATHOLOGICAL FRACTURES AGAINST THE BACKGROUND OF EXTENSIVE METASTATIC SPREAD IN COMBINATION WITH RADIO- AND CHEMOTHERAPY

    Directory of Open Access Journals (Sweden)

    R. M. Tikhilov

    2010-01-01

    Full Text Available The results of the stabilizing spine osteosynthesis in 82 patients with extensive metastatic spread are presented. Patients have been distributed to 3 groups: in I group the extended osteosynthesis of a spine without application cement vertebroplasty was carried out, in II group the extended spine osteosynthesis was performed, but with performance vertebroplasty through cannulated screws, in III group the limited osteosynthesis with cement vertebroplasty through cannulas screws was applied. Results of treatment were estimated considering spine support ability, elimination of a painful syndrome (scale of pain McAfee, 1989 and neurologic dysfunctions (scale ASIA/IMSOP, 1992, improvement of quality of a life (scale SF-36. The received positive results of treatment allow to conclude that tactics of treatment has been chosen correctly.

  10. Fractal Structures For Fixed Mems Capacitors

    KAUST Repository

    Elshurafa, Amro M.

    2014-08-28

    An embodiment of a fractal fixed capacitor comprises a capacitor body in a microelectromechanical system (MEMS) structure. The capacitor body has a first plate with a fractal shape separated by a horizontal distance from a second plate with a fractal shape. The first plate and the second plate are within the same plane. Such a fractal fixed capacitor further comprises a substrate above which the capacitor body is positioned.

  11. Fractal Structures For Fixed Mems Capacitors

    KAUST Repository

    Elshurafa, Amro M.; Radwan, Ahmed Gomaa Ahmed; Emira, Ahmed A.; Salama, Khaled N.

    2014-01-01

    An embodiment of a fractal fixed capacitor comprises a capacitor body in a microelectromechanical system (MEMS) structure. The capacitor body has a first plate with a fractal shape separated by a horizontal distance from a second plate with a fractal shape. The first plate and the second plate are within the same plane. Such a fractal fixed capacitor further comprises a substrate above which the capacitor body is positioned.

  12. Resorbable triangular plate for osteosynthesis of fractures of the condylar neck.

    Science.gov (United States)

    Lauer, Günter; Pradel, Winnie; Leonhardt, Henry; Loukota, Richard; Eckelt, Uwe

    2010-10-01

    We describe a new design of resorbable plate for use in the treatment of fractures of the condylar neck, and report the outcome of initial treatment in two patients. Copyright © 2009 The British Association of Oral and Maxillofacial Surgeons. All rights reserved.

  13. A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

    Directory of Open Access Journals (Sweden)

    Prakash Jayakumar

    2015-04-01

    Full Text Available Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking screw, which must also avoid the olecranon, coronoid, and radial fossae. We describe 3 patients (ages 27, 49, and 73 years with a bicolumnar fracture of the distal humerus where very short distal locking screws were used. Intra-articular screw placement was avoided but loss of fixation occurred in two patients and a third was treated with a prolonged period of immobilization. We postulate that fixed-angle screw trajectories may make it difficult for the surgeon to place screws of adequate length in this anatomically confined region, and may lead to insufficient distal fixation. Surgical tactics should include placement of as many screws as possible into the distal fragment, as long as possible, and that each screw pass through a plate without necessarily locking in.

  14. Fast centroid algorithm for determining the surface plasmon resonance angle using the fixed-boundary method

    International Nuclear Information System (INIS)

    Zhan, Shuyue; Wang, Xiaoping; Liu, Yuling

    2011-01-01

    To simplify the algorithm for determining the surface plasmon resonance (SPR) angle for special applications and development trends, a fast method for determining an SPR angle, called the fixed-boundary centroid algorithm, has been proposed. Two experiments were conducted to compare three centroid algorithms from the aspects of the operation time, sensitivity to shot noise, signal-to-noise ratio (SNR), resolution, and measurement range. Although the measurement range of this method was narrower, the other performance indices were all better than the other two centroid methods. This method has outstanding performance, high speed, good conformity, low error and a high SNR and resolution. It thus has the potential to be widely adopted

  15. Complications after osteosynthesis and their causes

    International Nuclear Information System (INIS)

    Lechner, S.

    1982-01-01

    From 1976 to 1981, 1,426 osteosyntheses were carried through according to the methods of the study group on questions of osteosynthesis. Complications occurred in 73 patients and consisted in the fracture or bending of the implant, or non-union. This led to an epicritical scrutiny of the case histories and X-ray images of these 73 patients in order to ascertain the causes underlying these complications, and to find out to what extent these problems can be recognized at an early date after the operation. (orig./MG) [de

  16. Concentration of solar radiation by white painted transparent plates.

    Science.gov (United States)

    Smestad, G; Hamill, P

    1982-04-01

    A simple flat-plate solar concentrator is described in this paper. The device is composed of a white painted transparent plate with a photovoltaic cell fixed to an unpainted area on the bottom of the plate. Light scattering off the white material is either lost or directed to the solar cell. Experimental concentrations of up to 1.9 times the incident solar flux have been achieved using white clays. These values are close to those predicted by theory for the experimental parameters investigated. A theory of the device operation is developed. Using this theory suggestions are made for optimizing the concentrator system. For reasonable choices of cell and plate size and reflectivities of 80% concentrations of over 2x are possible. The concentrator has the advantage over other systems in that the concentration is independent of incidence angle and the concentrator is easy to produce. The device needs no tracking system and will concentrate on a cloudy day.

  17. [Osteosynthesis-associated infections : Epidemiology, definition and diagnosis].

    Science.gov (United States)

    Renz, N; Feihl, S; Dlaska, C E; Schütz, M A; Trampuz, A

    2017-06-01

    Osteosynthesis-associated infections occur in 1-5% after closed and in up to 30% after open fractures. There are three different descriptions of implant-associated infections after fracture fixation, which are crucial for the selection of the adequate treatment strategy; temporal appearance from the index surgery (early versus late), pathogenesis of the infection (exogenous, hematogenous and contiguous from an adjacent focus), duration of infection symptoms (acute versus chronic). Diagnosis of osteosynthesis-associated infection is challenging, as chronic low-grade infections often present only with unspecific and subtle clinical symptoms. History, clinical evaluation, imaging, histopathlogical and microbiological examination build the cornerstones of diagnostics in implant-associated infections. A new onset of rest pain, early loosening of the prosthesis or mechanically unexplained, nonunion should raise suspicion for infection and prompt further evaluation. Percutaneous sinus tracts, purulent wound secretion and skin erosions with visibility of the implant confirm the implant-associated infection. Elevated C‑reactive protein value in blood is a supportive argument for infection, but is neither sensitive nor specific for infection. Imaging plays a key role to detect nonunions, infectious callus, sequester, peri-implant osteolysis and extraosseous and intramedullary involvement. Through microbiological and histopathological examination of intraoperative tissue samples, as well as sonication of explanted implants the causative pathogen is identified in most cases.

  18. Locking plate osteosynthesis in displaced 4-part fractures of the proximal humerus

    DEFF Research Database (Denmark)

    Brorson, Stig; Frich, Lars H; Winther, Annika

    2011-01-01

    There is considerable uncertainty about the optimal treatment of displaced 4-part fractures of the proximal humerus. Within the last decade, locking plate technology has been considered a breakthrough in the treatment of these complex injuries....

  19. The anterior tilt angle of the proximal tibia epiphyseal plate: A significant radiological finding in young children with trampoline fractures

    Energy Technology Data Exchange (ETDEWEB)

    Stranzinger, Enno, E-mail: enno.stranzinger@insel.ch [University Hospital Bern, Inselspital, Department of Diagnostic, Interventional and Pediatric Radiology, CH-3010 Bern (Switzerland); Leidolt, Lars, E-mail: lars.leidolt@insel.ch [University Hospital Bern, Inselspital, Department of Diagnostic, Interventional and Pediatric Radiology, CH-3010 Bern (Switzerland); Eich, Georg, E-mail: georg.eich@ksa.ch [Cantonal Hospital Aarau, Pediatric Radiology, Tellstrasse, CH-5001 Aarau (Switzerland); Klimek, Peter Michael, E-mail: peter.klimek@ksa.ch [Cantonal Hospital Aarau, Pediatric Surgery, Tellstrasse, CH-5001 Aarau (Switzerland)

    2014-08-15

    Objective: Evaluation of the anterior tilt angle of the proximal tibia epiphyseal plate in young children, which suffered a trampoline fracture in comparison with a normal population. Materials and methods: 62 children (31 females, 31 males) between 2 and 5 years of age (average 2 years 11 months, standard deviation 11 months) with radiographs in two views of the tibia were included in this retrospective study. 25 children with proximal tibia fractures were injured with a history of jumping on a trampoline. All other causes for tibia fractures were excluded. A normal age-mapped control cohort of 37 children was compared. These children had neither evidence of a trampoline related injury nor a fracture of the tibia. The anterior tilt angle of the epiphyseal plate of the tibia was defined as an angle between the proximal tibia physis and the distal tibia physis on a lateral view. Two radiologists evaluated all radiographs for fractures and measured the anterior tilt angle in consensus. An unpaired Student's t-test was used for statistical analysis (SPSS). Original reports were reviewed and compared with the radiological findings and follow-up radiographs. Results: In the normal control group, the average anterior tilt angle measured −3.2°, SD ± 2.8°. The children with trampoline fractures showed an anterior tilt of +4.4°, SD ± 2.9°. The difference was statistically significant, P < 0.0001. In 6 patients (24% of all patients with confirmed fractures) the original report missed to diagnose the proximal tibial fracture. Conclusion: Young children between 2 and 5 years of age are at risk for proximal tibia fractures while jumping on a trampoline. These fractures may be very subtle and difficult to detect on initial radiographs. Measurement of the anterior tilt angle of the proximal tibia epiphyseal plate on lateral radiographs is supportive for interpreting correctly trampoline fractures.

  20. The anterior tilt angle of the proximal tibia epiphyseal plate: A significant radiological finding in young children with trampoline fractures

    International Nuclear Information System (INIS)

    Stranzinger, Enno; Leidolt, Lars; Eich, Georg; Klimek, Peter Michael

    2014-01-01

    Objective: Evaluation of the anterior tilt angle of the proximal tibia epiphyseal plate in young children, which suffered a trampoline fracture in comparison with a normal population. Materials and methods: 62 children (31 females, 31 males) between 2 and 5 years of age (average 2 years 11 months, standard deviation 11 months) with radiographs in two views of the tibia were included in this retrospective study. 25 children with proximal tibia fractures were injured with a history of jumping on a trampoline. All other causes for tibia fractures were excluded. A normal age-mapped control cohort of 37 children was compared. These children had neither evidence of a trampoline related injury nor a fracture of the tibia. The anterior tilt angle of the epiphyseal plate of the tibia was defined as an angle between the proximal tibia physis and the distal tibia physis on a lateral view. Two radiologists evaluated all radiographs for fractures and measured the anterior tilt angle in consensus. An unpaired Student's t-test was used for statistical analysis (SPSS). Original reports were reviewed and compared with the radiological findings and follow-up radiographs. Results: In the normal control group, the average anterior tilt angle measured −3.2°, SD ± 2.8°. The children with trampoline fractures showed an anterior tilt of +4.4°, SD ± 2.9°. The difference was statistically significant, P < 0.0001. In 6 patients (24% of all patients with confirmed fractures) the original report missed to diagnose the proximal tibial fracture. Conclusion: Young children between 2 and 5 years of age are at risk for proximal tibia fractures while jumping on a trampoline. These fractures may be very subtle and difficult to detect on initial radiographs. Measurement of the anterior tilt angle of the proximal tibia epiphyseal plate on lateral radiographs is supportive for interpreting correctly trampoline fractures

  1. Trochanteric fractures. Classification and mechanical stability in McLaughlin, Ender and Richard osteosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Herrlin, K.; Stroemberg, T.; Lidgren, L.; Walloee, A.; Pettersson, H.

    Four hundred and thirty trochanteric factures operated upon with McLaughlin, Ender or Richard's osteosynthesis were divided into 6 different types based on their radiographic appearance before and immediately after reposition with special reference to the medial cortical support. A significant correlation was found between the fracture type and subsequent mechanical complications where types 1 and 2 gave less, and types 4 and 5 more complications. A comparison of the various osteosyntheses showed that Richard's had significantly fewer complications than either the Ender or McLaughlin types. For Richard's osteosynthesis alone no correlation to fracture type could be made because of the small number of complications in this group.

  2. Percutaneous osteosynthesis in the pelvis in cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Deschamps, Frederic; Baere, Thierry de; Tselikas, Lambros [Gustave Roussy, Interventional Radiology Department, Villejuif (France); Univeristy Paris-Sud, Le Kremlin Bicetre (France); Hakime, Antoine; Pearson, Ernesto; Farouil, Geoffroy; Teriitehau, Christophe [Gustave Roussy, Interventional Radiology Department, Villejuif (France)

    2016-06-15

    Screw fixation (osteosynthesis) can be performed percutaneously by interventional radiologists. We report our experience in cancer patients. We retrospectively reviewed all cases of percutaneous osteosynthesis (PO) of the pelvic ring and proximal femur performed in our hospital. PO were performed for fracture palliation or for osteolytic metastases consolidation. Screws were inserted under CT- or cone-beam CT- guidance and general anaesthesia. Patients were followed-up with pelvic-CT and medical consultation at 1 month, then every 3 months. For fractures, the goal was pain palliation and for osteolytic metastases, pathologic fracture prevention. Between February 2010 and August 2014, 64 cancer patients were treated with PO. Twenty-one patients had PO alone for 33 painful fractures (13 bone-insufficiency, 20 pathologic fractures). The pain was significantly improved at 1 month (VAS score = 20/100 vs. 80/100). In addition, 43 cancer patients were preventively consolidated using PO plus cementoplasty for 45 impending pathologic fractures (10 iliac crests, 35 proximal femurs). For the iliac crests, no fracture occurred (median-FU = 75 days). For the proximal femurs, 2 pathological fractures occurred (fracture rate = 5.7 %, median-FU = 205 days). PO is a new tool in the therapeutic arsenal of interventional radiologists for bone pain management. (orig.)

  3. Modeling the effect of the inclination angle on natural convection from a flat plate: The case of a photovoltaic module

    Directory of Open Access Journals (Sweden)

    Perović Bojan D.

    2017-01-01

    Full Text Available The main purpose of this paper is to show how the inclination angle affects natural convection from a flat-plate photovoltaic module which is mounted on the ground surface. In order to model this effect, novel correlations for natural convection from isothermal flat plates are developed by using the fundamental dimensionless number. On the basis of the available experimental and numerical results, it is shown that the natural convection correlations correspond well with the existing empirical correlations for vertical, inclined, and horizontal plates. Five additional correlations for the critical Grashof number are derived from the available data, three indicating the onset of transitional flow regime and two indicating the onset of flow separation. The proposed correlations cover the entire range of inclination angles and the entire range of Prandtl numbers. This paper also provides two worked examples, one for natural convection combined with radiation and one for natural convection combined with forced convection and radiation. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. TR33046

  4. A Prospective Randomized Study on Operative Treatment for Simple Distal Tibial Fractures-Minimally Invasive Plate Osteosynthesis Versus Minimal Open Reduction and Internal Fixation.

    Science.gov (United States)

    Kim, Ji Wan; Kim, Hyun Uk; Oh, Chang-Wug; Kim, Joon-Woo; Park, Ki Chul

    2018-01-01

    To compare the radiologic and clinical results of minimally invasive plate osteosynthesis (MIPO) and minimal open reduction and internal fixation (ORIF) for simple distal tibial fractures. Randomized prospective study. Three level 1 trauma centers. Fifty-eight patients with simple and distal tibial fractures were randomized into a MIPO group (treatment with MIPO; n = 29) or a minimal group (treatment with minimal ORIF; n = 29). These numbers were designed to define the rate of soft tissue complication; therefore, validation of superiority in union time or determination of differences in rates of delayed union was limited in this study. Simple distal tibial fractures treated with MIPO or minimal ORIF. The clinical outcome measurements included operative time, radiation exposure time, and soft tissue complications. To evaluate a patient's function, the American Orthopedic Foot and Ankle Society ankle score (AOFAS) was used. Radiologic measurements included fracture alignment, delayed union, and union time. All patients acquired bone union without any secondary intervention. The mean union time was 17.4 weeks and 16.3 weeks in the MIPO and minimal groups, respectively. There was 1 case of delayed union and 1 case of superficial infection in each group. The radiation exposure time was shorter in the minimal group than in the MIPO group. Coronal angulation showed a difference between both groups. The American Orthopedic Foot and Ankle Society ankle scores were 86.0 and 86.7 in the MIPO and minimal groups, respectively. Minimal ORIF resulted in similar outcomes, with no increased rate of soft tissue problems compared to MIPO. Both MIPO and minimal ORIF have high union rates and good functional outcomes for simple distal tibial fractures. Minimal ORIF did not result in increased rates of infection and wound dehiscence. Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.

  5. OUTCOME OF LOCKING PLATES IN DISTAL TIBIA FRACTURES TREATMENT

    Directory of Open Access Journals (Sweden)

    Lokesh

    2016-05-01

    Full Text Available INTRODUCTION Most of these fractures except intra-articular fractures are treated with interlocking nail. 1,2 These nails are a boon for these fractures. But as the fracture nears to the joint stability the fracture fixation will be compromised due to malreduction and alignment, it leads to increased chances of delayed and nonunion. 3 Locking anatomical plates are evaluated for anatomical and relative stability fixation. Since then most intra and near intra-articular fractures are fixed with these plates with minimally invasive percutaneous plate osteosynthesis method, these plates have given excellent result 4 . But again these plates have some disadvantages 5 . This study is done to see the outcome of locking plates in distal tibia fracture. METHODS This study is done in the Department of Orthopaedics, Bangalore Medical College, Bangalore. This study is done from 2013 to 2015. 30 patients who came to outpatient department were treated with locking plates. All patients above 16 years having distal third tibia fracture are included. All open fractures except type 1 and elderly above 60 years and pathological fractures are excluded in our study. All patients were followed up for initial 5 months, thereafter, once in 3 months, for clinical and radiological evaluation of union status, knee range of motion, ankle range of motion and other complications. Assessment of the patient with functional recovery was done with American Orthopaedic Foot and Ankle Surgery(AOFAS 6 minimum 5 months after injury. RESULTS Majority of the patients are from age group 18-29 years (50%. Average age group was 30 years. Majority of the patients were males 80.6% (25. All fractures were closed fractures except 2 cases which are type 1. There were 12 cases of AO type A, 8 patients were AO type B and 10 patients were type C. Majority of the patients had fracture due to road traffic accidents, 74%. All fractures were united by the end of 20 weeks. There was delayed union in

  6. Modeling the effect of the inclination angle on natural convection from a flat plate: The case of a photovoltaic module

    OpenAIRE

    Perović Bojan D.; Klimenta Jelena Lj.; Tasić Dragan S.; Peuteman Joan L.G.; Klimenta Dardan O.; Anđelković Ljiljana N.

    2017-01-01

    The main purpose of this paper is to show how the inclination angle affects natural convection from a flat-plate photovoltaic module which is mounted on the ground surface. In order to model this effect, novel correlations for natural convection from isothermal flat plates are developed by using the fundamental dimensionless number. On the basis of the available experimental and numerical results, it is shown that the natural convection correlations correspond well with the existing empirical...

  7. Simulations of a phase corrector plate for the National Ignition Facility

    International Nuclear Information System (INIS)

    Williams, W. H. LLNL

    1998-01-01

    Simulations are presented on the effect of placing a static phase corrector plate in each beamline of the National Ignition Facility (NIF) to assist the adaptive optic in correcting beam phase aberrations. Results indicate such a plate could significantly improve the focal spot, reducing a 3ω, 80% spot half-angle from 21 to 8 microrad for poorer-qualtiy optics, and 17 to 7 for better optics. Such a plate appears to be within the range of current fabrication technologies. It would have an alignment requiremnt of ±0.5 mm, if placed in the front end. In NIF operation, the occasional replacement of laser slabs would slowly degrade the beam quality for a fixed corrector plate, with the spot size increasing from 8 to 15 microrad after four new slabs for poorer optics, and 7 to 12 microrad for better optics. The energy fraciton clipped on the injection pinhole (±100 microrad) would be <0.5% due to this pre-correction

  8. Study on the CO2 electric driven fixed swash plate type compressor for eco-friendly vehicles

    Science.gov (United States)

    Nam, Donglim; Kim, Kitae; Lee, Jehie; Kwon, Yunki; Lee, Geonho

    2017-08-01

    The purpose of this study is to experiment and to performance analysis about the electric-driven fixed swash plate compressor using alternate refrigerant(R744). Comprehensive simulation model for an electric driven compressor using CO2 for eco-friendly vehicle is presented. This model consists of compression model and dynamic model. The compression model included valve dynamics, leakage, and heat transfer models. And the dynamic model included frictional loss between piston ring and cylinder wall, frictional loss between shoe and swash plate, frictional loss of bearings, and electric efficiency. Especially, because the efficiency of an electric parts(motor and inverter) in the compressor affects the loss of the compressor, the dynamo test was performed. We made the designed compressor, and tested the performance of the compressor about the variety pressure conditions. Also we compared the performance analysis result and performance test result.

  9. Angle measurement with laser feedback instrument.

    Science.gov (United States)

    Chen, Wenxue; Zhang, Shulian; Long, Xingwu

    2013-04-08

    An instrument for angle measurement based on laser feedback has been designed. The measurement technique is based on the principle that when a wave plate placed into a feedback cavity rotates, its phase retardation varies. Phase retardation is a function of the rotating angle of the wave plate. Hence, the angle can be converted to phase retardation. The phase retardation is measured at certain characteristic points identified in the laser outputting curve that are then modulated by laser feedback. The angle of a rotating object can be measured if it is connected to the wave plate. The main advantages of this instrument are: high resolution, compact, flexible, low cost, effective power, and fast response.

  10. Equine ulnar fracture repair with locking compression plates can be associated with inadvertent penetration of the lateral cortex of the radius.

    Science.gov (United States)

    Kuemmerle, Jan M; Kühn, Karolin; Bryner, Marco; Fürst, Anton E

    2013-10-01

    To evaluate if the use of locking head screws (LHS) in the distal holes of a locking compression plate (LCP) applied to the caudal aspect of the ulna to treat equine ulnar fractures is associated with a risk of injury to the lateral cortex of the radius. Controlled laboratory study. Cadaveric equine forelimbs (n = 8 pair). After transverse ulnar osteotomy, osteosynthesis was performed with a narrow 10-13 hole 4.5/5.0 LCP applied to the caudal aspect of each ulna. The distal 3 holes were filled with 4.5 mm cortex screws (CS) in 1 limb (group 1) and with 5.0 mm LHS contralaterally (group 2). CS were inserted in an angle deemed appropriate by the surgeon and LHS were inserted perpendicular to the plate. Implant position and injury to the lateral cortex of the radius were assessed by radiography, CT, and limb dissection. In group 1, injury of the lateral radius cortex did not occur. In group 2, 4 limbs and 6/24 LHS were associated with injury of the lateral radius cortex by penetration of a LHS. This difference was statistically significant. CS were inserted with a mean angle of 17.6° from the sagittal plane in a caudolateral-craniomedial direction. Use of LHS in the distal part of a LCP applied to the caudal aspect of the ulna is associated with a risk of inadvertent injury to the lateral cortex of the radius. © Copyright 2013 by The American College of Veterinary Surgeons.

  11. Effect on infection resistance of a local antiseptic and antibiotic coating on osteosynthesis implants: an in vitro and in vivo study.

    Science.gov (United States)

    Kälicke, Thomas; Schierholz, Jörg; Schlegel, Urs; Frangen, Thomas Manfred; Köller, Manfred; Printzen, Gert; Seybold, Dominik; Klöckner, Stefan; Muhr, Gert; Arens, Stephan

    2006-08-01

    The purpose of this study was to acquire information about the effect of an antibacterial and biodegradable poly-L-lactide (PLLA) coated titanium plate osteosynthesis on local infection resistance. For our in vitro and in vivo experiments, we used six-hole AO DC minifragment titanium plates. The implants were coated with biodegradable, semiamorphous PLLA (coating about 30 microm thick). This acted as a carrier substance to which either antibiotics or antiseptics were added. The antibiotic we applied was a combination of Rifampicin and fusidic acid; the antiseptic was a combination of Octenidin and Irgasan. This produced the following groups: Group I: six-hole AO DC minifragment titanium plate without PLLA; Group II: six-hole AO DC minifragment titanium plate with PLLA without antibiotics/antiseptics; Group III: six-hole AO DC minifragment titanium plate with PLLA + 3% Rifampicin and 7% fusidic acid; Group IV: six-hole AO DC minifragment titanium plate with PLLA + 2% Octenidin and 8% Irgasan. In vitro, we investigated the degradation and the release of the PLLA coating over a period of 6 weeks, the bactericidal efficacy of antibiotics/antiseptics after their release from the coating and the bacterial adhesion of Staphylococcus aureus to the implants. In vivo, we compared the infection rates in white New Zealand rabbits after titanium plate osteosynthesis of the tibia with or without antibacterial coating after local percutaneous bacterial inoculations at different concentrations (2 x 10(5)-2 x 10(8)): The plate, the contaminated soft tissues and the underlying bone were removed under sterile conditions after 28 days and quantitatively evaluated for bacterial growth. A stepwise experimental design with an "up-and-down" dosage technique was used to adjust the bacterial challenge in the area of the ID50 (50% infection dose). Statistical evaluation of the differences between the infection rates of both groups was performed using the two-sided Fisher exact test (p

  12. Early results for treatment of two- and three-part fractures of the proximal humerus using Contours PHP (proximal humeral plate).

    Science.gov (United States)

    Biazzo, Alessio; Cardile, Carlo; Brunelli, Luca; Ragni, Paolo; Clementi, Daniele

    2017-04-28

    The management of displaced 2- and 3-part fractures of the proximal humerus is controversial, both in younger and in elderly patients. The purpose of this paper is to evaluate the functional results of the Contours Proximal Humerus Plate (OrthofixR, Bussolengo,Verona, Italy), for the treatment of displaced 2- and 3-part fractures of the proximal humerus. We retrospectively reviewed 55 patients with proximal humerus fractures, who underwent osteosynthesis with Contours Proximal Humerus Plate from December 2011 to March 2015. We had 21 patients with 2-part fractures and with an average age of 67.1 years and 34 patients with 3-part fractures, with average age of 63.6 years. The average union time was 3 months. The mean Constant score was 67 for 2-part fracture group and 64.9 for 3-part fracture group. The difference was not statistically significant (p = 0.18). The overall complication rate was 14.5 %. Six patients underwent additional surgery (10.9%). The most frequent major complication was secondary loss of reduction following varus collapse of the fracture (2 cases). In these patients, there was loss of medial hinge integrity due to impaction and osteoporosis. The placement of the main locking screw in the calcar area to provide inferomedial support is the rational of the Contours Proximal Humerus Plate. Osteosynthesis with Contours Proximal Humerus Plate is a safe system for treating displaced 2- and 3-part fractures of the proximal humerus, with good functional results and complication rates comparable to those reported in the literature.

  13. Indirect reduction with a condylar blade plate for osteosynthesis of subtrochanteric femoral fractures.

    Science.gov (United States)

    Siebenrock, K A; Müller, U; Ganz, R

    1998-01-01

    Subtrochanteric fractures frequently occur as high energy trauma usually in younger patients and may lead to severe comminution of the medial cortex. The medial cortex of the proximal femur is exposed to high compressive forces which make fracture stabilization a difficult problem. Bone healing may be seriously compromised due to extensive comminution and fragment devitalization. This requires reduction techniques which do not cause additional damage to the vitality of the bone. With indirect reduction techniques and the use of a condylar blade plate the results have been significantly improved in these fracture types in our department (1). In this report the essential aspects of indirect reduction for subtrochanteric fractures using a condylar blade plate and the treatment results from our department from earlier years (1) and from the last 2 1/2 years will be presented. In the latter period, fifteen patients with a mean age of 49 years (19-87 years) were treated with this method. Fractures resulted from traffic incidents or falls from a great height in 11 cases (73%). Union was achieved in 14 cases (93%) with full weight-bearing after a mean of 3 months (1-4 1/2 months). Malunion was seen in two cases (13%) without the need for further surgery. Non union occurred in one patient (7%) with a III B open injury due to early infection. After repeated debridements, bone grafting and decortication, the fracture was stabilized with a replacement condylar blade plate and healed uneventfully.

  14. Clinical case for the use of intramedullary osteosynthesis in the treatment of pathological fractures of the femur in 6-day newborn girls with a high partial intestinal obstruction

    Directory of Open Access Journals (Sweden)

    Evgeny G. Skryabin

    2017-06-01

    Full Text Available Abstract. Skeletal bone fractures in newborns present a problem of modern traumatology. Aim. The goal is to present the use of the method of intramedullary osteosynthesis in the treatment of a pathological fracture of the right femur in a newborn girl to a wide audience of pediatric orthopedic traumatologists. Material and methods. We have experience in the treatment of a 6-day-old girl, who was born with intrauterine growth retardation and bowel disease. On the second day of stay in the intensive care unit, she had a pathological fracture of the right femur. Diagnosis of the pathological fracture was established based upon the results of clinical examination and radiography of the injured limb segment. Results. Immediately after the diagnosis, the right lower limb of the child was fixed with a plaster bandage. On the control radiographs, the standing of the bone fragments were unsatisfactory, and a decision was made to use the intramedullary osteosynthesis method with a knitting needle on the 6th day after birth of the child. The need for surgical treatment of a fracture of the femur was due to a congenital abnormality of the intestine in the child, and a need to perform surgery on the abdominal organs. Discussion. Spontaneous fracture of the right femur occurred in the child in treatment in the intensive care unit. The cause of the fracture was osteopenic syndrome, which developed as a result of vitamin D deficiency. During the first 12 days of her life, the newborn had two laparoscopic operations to address the intestinal pathology. Four weeks after the operation using osteosynthesis, the metal from the bone marrow channel of the right femur was removed. After the removal of the needle, the correct axis of the operated segment was fixed to the same length of the lower extremities. The patient had absence of pathological mobility in the fracture region, and full amplitude of movements in the knee and hip joints. Conclusion. When receiving

  15. Midterm Follow-up of Treating Volar Marginal Rim Fractures with Variable Angle Lcp Volar Rim Distal Radius Plates.

    Science.gov (United States)

    Goorens, Chul Ki; Geeurickx, Stijn; Wernaers, Pascal; Staelens, Barbara; Scheerlinck, Thierry; Goubau, Jean

    2017-06-01

    Specific treatment of the volar marginal rim fragment of distal radius fractures avoids occurance of volar radiocarpal dislocation. Although several fixation systems are available to capture this fragment, adequately maintaining internal fixation is difficult. We present our experience of the first 10 cases using the 2.4 mm variable angle LCP volar rim distal radius plate (Depuy Synthes®, West Chester, US), a low-profile volar rim-contouring plate designed for distal plate positioning and stable buttressing of the volar marginal fragment. Follow-up patient satisfaction, range of motion, grips strength, functional scoring with the QuickDASH and residual pain with a numeric rating scale were assessed. Radiological evaluation consisted in evaluating fracture consolidation, ulnar variance, volar angulation and maintenance of the volar rim fixation. The female to male ratio was 5:5 and the mean age was 52.2 (range, 17-80) years. The mean follow-up period was 11 (range, 5-19) months postoperatively. Patient satisfaction was high. The mean total flexion/extension range was 144° (range, 100-180°) compared to the contralateral uninjured side 160° (range, 95-180°). The mean total pronation/supination range was 153° (range, 140-180°) compared to the contralateral uninjured side 170° (range, 155-180°). Mean grip strength was 14 kg (range, 9-22), compared to the contralateral uninjured side 20 kg (range, 12-25 kg). Mean pre-injury level activity QuickDASH was 23 (range, 0-34.1), while post-recovery QuickDASH was 25 (range 0-43.2). Residual pain was 1.5 on the visual numerical pain rating scale. Radiological evaluation revealed in all cases fracture consolidation, satisfactory reconstruction of ulnar variance, volar angulation and volar rim. We encountered no flexor tendon complications, although plate removal was systematically performed after fracture consolidation. The 2.4 mm variable angle LCP volar rim distal radius plates is a valid treatment option for treating

  16. Periprosthetic Vancouver type B1 and C fractures treated by locking-plate osteosynthesis

    DEFF Research Database (Denmark)

    Froberg, Lonnie; Troelsen, Anders; Brix, Michael

    2012-01-01

    Historically, the treatment of periprosthetic femoral fractures (PFFs) has been associated with a high frequency of complications and reoperations. The preferred treatment is internal fixation, a revision of the femoral stem, or a combination of both. An improved understanding of plate use during...

  17. The stability of mandibular prognathism corrected by bilateral sagittal split osteotomies: a comparison of bi-cortical osteosynthesis and mono-cortical osteosynthesis.

    Science.gov (United States)

    Hsu, S S-P; Huang, C-S; Chen, P K-T; Ko, E W-C; Chen, Y-R

    2012-02-01

    This study evaluated the differences in surgical changes and post-surgical changes between bi-cortical and mono-cortical osteosynthesis (MCO) in the correction of skeletal Class III malocclusion with bilateral sagittal split osteotomies (BSSOs). Twenty-five patients had bi-cortical osteosynthesis (BCO), 32 patients had mono-cortical fixation. Lateral and postero-anterior cephalometric radiographs, taken at the time of surgery, before surgery, 1 month after surgery, and on completion of orthodontic treatment (mean 9.9 months after surgery), were obtained for evaluation. Cephalometric analysis and superimposition were used to investigate the surgical and post-surgical changes. Independent t-test was performed to compare the difference between the two groups. Pearson's correlations were tested to evaluate the factors related to the relapse of the mandible. The sagittal relapse rate was 20% in the bi-cortical and 25% in the mono-cortical group. The forward-upward rotation of the mandible in the post-surgical period contributed most of the sagittal relapse. There were no statistically significant differences in sagittal and vertical changes between the two groups during surgery and in the post-surgical period. No factors were found to correlate with post-surgical relapse, but the intergonial width increased more in the bi-cortical group. The study suggested that both methods of skeletal fixation had similar postoperative stability. Copyright © 2011 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  18. Parallel-plate third sound waveguides with fixed and variable plate spacings for the study of fifth sound in superfluid helium

    International Nuclear Information System (INIS)

    Jelatis, G.J.

    1983-01-01

    Third sound in superfluid helium four films has been investigated using two parallel-plate waveguides. These investigations led to the observation of fifth sound, a new mode of sound propagation. Both waveguides consisted of two parallel pieces of vitreous quartz. The sound speed was obtained by measuring the time-of-flight of pulsed third sound over a known distance. Investigations from 1.0-1.7K were possible with the use of superconducting bolometers, which measure the temperature component of the third sound wave. Observations were initially made with a waveguide having a plate separation fixed at five microns. Adiabatic third sound was measured in the geometry. Isothermal third sound was also observed, using the usual, single-substrate technique. Fifth sound speeds, calculated from the two-fluid theory of helium and the speeds of the two forms of third sound, agreed in size and temperature dependence with theoretical predictions. Nevertheless, only equivocal observations of fifth sound were made. As a result, the film-substrate interaction was examined, and estimates of the Kapitza conductance were made. Assuming the dominance of the effects of this conductance over those due to the ECEs led to a new expression for fifth sound. A reanalysis of the initial data was made, which contained no adjustable parameters. The observation of fifth sound was seen to be consistent with the existence of an anomalously low boundary conductance

  19. Effect of Rake Angle During Machining of Micro Grooves on Electroless Nickel Plated Die Materials

    International Nuclear Information System (INIS)

    Rezaur Rahman, K.M.; Rahman, M.

    2005-01-01

    This study attempts to evaluate the performance of two single crystal diamond tools with different rake angle (0 0 and -15 0 ) during micro grooving on electroless nickel plated die materials. It was found that the 0 0 rake diamond tool has superior performance compared to the -15 0 rake angle tool. The negative rake tool experienced very high thrust force, and severe chipping on the flank face was evident after a short cutting distance of 3.13 km. On the other hand, the 0 0 rake tool machined satisfactorily up to 50 km without any significant tool wear. While machining with the -15 0 rake tool, significant change in surface roughness with spindle speed was observed compared to the 0 0 rake tool. With increasing infeed rate variation in surface roughness was evident only with the -15 0 rake tool. Steep change in roughness with machining distance was also observed while machining with the negative rake tool. (authors)

  20. Electropolishing of Stainless Steel Implants for Stable Functional Osteosynthesis

    Directory of Open Access Journals (Sweden)

    Omel’chuk, A.О.

    2016-01-01

    Full Text Available A new method for the electropolishing stainless steel for stable functional osteosynthesis has been developed. The polishing of implants was carried out in solutions, based on the ternary system H2SO4—H3PO4—H2O with stepwise decreasing the current density and increasing the orthophosphoric acid concentration. The optimal polishing conditions (current density, solution composition, temperature and duration have been determined. The developed method improves the quality and mechanical properties of the surface.

  1. PWR integral tie plate and locking mechanism

    International Nuclear Information System (INIS)

    Flora, B.S.; Osborne, J.L.

    1980-01-01

    A locking mechanism for securing an upper tie plate to the tie rods of a nuclear fuel bundle is described. The mechanism includes an upper tie plate assembly and locking sleeves fixed to the ends of the tie rods. The tie plate is part of the upper tie plate assembly and is secured to the fuel bundle by securing the entire upper tie plate assembly to the locking sleeves fixed to the tie rods. The assembly includes, in addition to the tie plate, locking nuts for engaging the locking sleeves, retaining sleeves to operably connect the locking nuts to the assembly, a spring biased reaction plate to restrain the locking nuts in the locked position and a means to facilitate the removal of the entire assembly as a unit from the fuel bundle

  2. The monocortical window (MCW): a modified split-crest technique adopting ligature osteosynthesis.

    Science.gov (United States)

    Contessi, Marcello

    2013-01-01

    Split-crest procedures performed with ultrasonic devices have proven to be a viable and effective surgical treatment when the alveolar ridge shows forms of resorption in thickness while its height remains virtually unchanged. However, in the case of stiff, type 1, corticalized mandibular bone, it may be very difficult or even impossible to have any elasticity and lateral augmentation in between the split bone walls. Furthermore, a complete detachment of the outer lamellae may also occur during expansion maneuvers or during implant insertion. This study describes the use of a steel-wire ligature osteosynthesis technique to give primary stability both to the expanded cortical window and to the implants themselves when they have none at all. This osteosynthesis is simple, quick, safe, and bone-saving in force delivery. It is also extremely cheap as well as being effective in obtaining ridge expansion, bone regeneration, and implant positioning in an all-in-one procedure. This article describes the foundations in the literature as well as new elements in the technique. Three short case studies are used by way of example.

  3. NATURAL TRANSVERSE VIBRATIONS OF A PRESTRESSED ORTHOTROPIC PLATE-STRIPE

    Directory of Open Access Journals (Sweden)

    Egorychev Oleg Aleksandrovich

    2012-10-01

    Full Text Available The article represents a new outlook at the boundary-value problem of natural vibrations of a homogeneous pre-stressed orthotropic plate-stripe. In the paper, the motion equation represents a new approximate hyperbolic equation (rather than a parabolic equation used in the majority of papers covering the same problem describing the vibration of a homogeneous orthotropic plate-stripe. The proposed research is based on newly derived boundary conditions describing the pin-edge, rigid, and elastic (vertical types of fixing, as well as the boundary conditions applicable to the unfixed edge of the plate. The paper contemplates the application of the Laplace transformation and a non-standard representation of a homogeneous differential equation with fixed factors. The article proposes a detailed representation of the problem of natural vibrations of a homogeneous orthotropic plate-stripe if rigidly fixed at opposite sides; besides, the article also provides frequency equations (no conclusions describing the plate characterized by the following boundary conditions: rigid fixing at one side and pin-edge fixing at the opposite side; pin-edge fixing at one side and free (unfixed other side; rigid fixing at one side and elastic fixing at the other side. The results described in the article may be helpful if applied in the construction sector whenever flat structural elements are considered. Moreover, specialists in solid mechanics and theory of elasticity may benefit from the ideas proposed in the article.

  4. Viewing device of a steam generator tube-plate

    International Nuclear Information System (INIS)

    Denis, J.; Poirier, D.

    1984-01-01

    The invention proposes a device to observe the tubular plate of a steam generator including rows of parallel tubes situated in a shell provided with at least one entrance situated face to the interval between two adjacent rows. The device comprises a boom of which transversal dimension is less important than the interval; the boom can be inserted by the entrance; it contains a rigid endoscope terminated in an eyepiece and an optical fibre lighguide in the same vertical plane for illumination of the far end. The respective rotary angled mirrors are driven simultaneously by drums connected to a rack-and-pinion mechanism which is operated by a plunger held by a spring against a rocking lever driven by a motor and cam. As the mirrors rotate, the illuminated zone overlaps the field of view of the endoscope. The tube plate area in the shadow of the endoscope mirror (20) is illuminated separately by an ailiary fibre with a fixed terminal mirror. The invention enables the observation of the tube plate on both sides of the boom. It can be used in the case of the inspection of the steam generator of a pressurized water reactor [fr

  5. Torsional Growth Modulation of Long Bones by Oblique Plating in a Rabbit Model.

    Science.gov (United States)

    Lazarus, David E; Farnsworth, Christine L; Jeffords, Megan E; Marino, Nikolas; Hallare, Jericho; Edmonds, Eric W

    2018-02-01

    There is evidence that oblique tension band plating can affect torsional growth in long bones. This study sought to determine if the torsional growth could be modulated based on the angles of the tension band plating and whether or not oblique plating affected overall longitudinal growth. New Zealand White rabbits (10.5 wk old) had one screw placed on the metaphyseal side and one on the epiphyseal side of both medial and lateral sides of the right knee distal femoral physis. The sham group (n=5) included screw placement only. For the plate group (n=13), unlocked plates, angled from 0 to 76 degrees, connected the screws and spanned the physis. Radiographs were taken at biweekly intervals. After 6 weeks of growth, hindlimbs were harvested and microCT scans performed. Femoral length, distances between screw heads and angle between the plates were measured on radiographs. Femoral length differences were compared between groups. Femoral version was measured from 3D microCT. Plate angle changes were correlated to the difference in femoral version between limbs using Pearson correlation (significance was set to P<0.05 for all comparisons). Femur length difference between the contralateral and the operative side was significantly greater in the plate group compared with the sham group over time (P=0.049). Medial and lateral screw distances changed significantly more in the sham group than the plate group on both sides (P<0.001). A greater initial angle between plates resulted in a greater change in the angle between plates (P<0.001). Significant correlations were found between right-left side femoral version differences and initial plate angle (P=0.003) and plate angle change (P=0.014). The torsional effect of oblique plating seems to correlate with the amount of initial plate angle, with an additional, not negligible, longitudinal growth effect. Placing plates at given angles across open physes may result in predictable changes in bone torsion allowing for a safer and

  6. Lateral malleolus hook plate for comminuted Weber A and B fractures: A retrospective study

    Directory of Open Access Journals (Sweden)

    Fang Zhenhua

    2013-01-01

    Full Text Available Background: The goal of managing the comminuted fracture of lateral malleolus is to restore length, rotation and alignment which might be more challenging with extensive comminution around the area of the distal tip. The common osteosynthesis techniques such as the one-third tubular plate, tension band wiring, K-wires, screws, or intramedullary nail may be insufficient in cases with a comminuted lateral malleolus. The anatomical hook plate is an alternative implant in such cases. We present our results of the comminuted lateral malleolar fractures (Weber A, B, managed by open reduction and internal fixation (ORIF with an anatomical hook plate of lateral malleolus (Königsee Implant Company, Germany. Materials and Methods: We retrospectively reviewed 20 patients of comminuted fracture of distal lateral malleolus between 2008 and 2010. There were 12 males and 8 females, right side was involved in 18 patients and left in 2. The mean age was 51.9 years (range 18-75 years. The fractures were categorized by Denis-Weber classification type A (n=1, B1 (n=1, B2 (n=13 and B3 (n=5. Nineteen cases were of closed injury and one of open injury (Gustilo Anderson type II. These patients underwent ORIF with a lateral malleolus anatomical hook plate. Followup including radiographs and clinical examinations were performed. The American Orthopedic Foot and Ankle Society (AOFAS ankle hindfoot scores were documented at followups. Results: The mean followup was 21.4 months (range 16-27 months. The average AOFAS score was 94.3 (range 78-100 points. A stable anatomic reduction and bony union were obtained in all the cases. The average time was 3.1 months (range 2.5-4 months. Four cases had complications like posttraumatic osteoarthritis, hardware impingement and superficial wound infection. Conclusion: A reasonably good stability can be obtained in distal most comminuted fractures of lateral malleolus with a lateral malleolus anatomical hook plate. We believe this

  7. Small Angle Neutron Scattering (sans) Studies on "SIDE-END FIXED" and "SIDE-ON FIXED" Liquid Crystal Polymers

    Science.gov (United States)

    Hardouin, F.; Noirez, L.; Keller, P.; Leroux, N.; Cotton, J. P.

    The following sections are included: * Introduction * Experimental * Results and discussion * Determination of the backbone conformation in the nematic and smectic A phases of "side-end fixed" L.C. polymethacrylates (PMA) or polyacrylates (PA) * Determination of the global and backbone conformation in the nematic and smectic A phases of "side-end fixed" L.C. polysiloxanes (PMS) * Determination of the backbone conformation in the unique nematic phase (without smectic A phase) or in the reentrant nematic phase (below smectic A phase) of "side-end fixed" L.C. polyacrylates (PA) * Determination of the global conformation in the nematic phase of "side-on fixed" L.C. polysiloxanes (PMS) * Determination of the global conformation in the nematic phase of "diluted side-on fixed" L.C. copolysiloxanes * Determination of the backbone conformation in the nematic phase of "side-on fixed" L.C. polyacrylates * Conclusions * References

  8. A prospective, randomised trial comparing closed intramedullary nailing with percutaneous plating in the treatment of distal metaphyseal fractures of the tibia.

    Science.gov (United States)

    Guo, J J; Tang, N; Yang, H L; Tang, T S

    2010-07-01

    We compared the outcome of closed intramedullary nailing with minimally invasive plate osteosynthesis using a percutaneous locked compression plate in patients with a distal metaphyseal fracture in a prospective study. A total of 85 patients were randomised to operative stabilisation either by a closed intramedullary nail (44) or by minimally invasive osteosynthesis with a compression plate (41). Pre-operative variables included the patients' age and the side and pattern of the fracture. Peri-operative variables were the operating time and the radiation time. Postoperative variables were wound problems, the time to union of the fracture, the functional American Orthopaedic Foot and Ankle surgery score and removal of hardware. We found no significant difference in the pre-operative variables or in the time to union in the two groups. However, the mean radiation time and operating time were significantly longer in the locked compression plate group (3.0 vs 2.12 minutes, p fractures had united. Patients who had intramedullary nailing had a higher mean pain score (40 = no pain, 0 = severe pain), [corrected] but better function, alignment and total American Orthopaedic Foot and Ankle surgery scores, although the differences were not statistically significant (p = 0.234, p = 0.157, p = 0.897, p = 0.177 respectively). Three (6.8%) patients in the intramedullary nailing group and six (14.6%) in the locked compression plate group showed delayed wound healing, and 37 (84.1%) in the former group and 38 (92.7%) in the latter group expressed a wish to have the implant removed. We conclude that both closed intramedullary nailing and a percutaneous locked compression plate can be used safely to treat Orthopaedic Trauma Association type-43A distal metaphyseal fractures of the tibia. However, closed intramedullary nailing has the advantage of a shorter operating and radiation time and easier removal of the implant. We therefore prefer closed intramedullary nailing for patients with

  9. Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation.

    Science.gov (United States)

    Lujan, Trevor J; Henderson, Chris E; Madey, Steven M; Fitzpatrick, Dan C; Marsh, J Lawrence; Bottlang, Michael

    2010-03-01

    Locked plating constructs may be too stiff to reliably promote secondary bone healing. This study used a novel imaging technique to quantify periosteal callus formation of distal femur fractures stabilized with locking plates. It investigated the effects of cortex-to-plate distance, bridging span, and implant material on periosteal callus formation. Retrospective cohort study. One Level I and one Level II trauma center. Sixty-four consecutive patients with distal femur fractures (AO types 32A, 33A-C) stabilized with periarticular locking plates. Osteosynthesis using indirect reduction and bridge plating with periarticular locking plates. Periosteal callus size on lateral and anteroposterior radiographs. Callus size varied from 0 to 650 mm2. Deficient callus (20 mm2 or less) formed in 52%, 47%, and 37% of fractures at 6, 12, and 24 weeks postsurgery, respectively. Callus formation was asymmetric, whereby the medial cortex had on average 64% more callus (P=0.001) than the anterior or posterior cortices. A longer bridge span correlated minimally with an increased callus size at Week 6 (P=0.02), but no correlation was found at Weeks 12 and 24 postsurgery. Compared with stainless steel plates, titanium plates had 76%, 71%, and 56% more callus at Week 6 (P=0.04), Week 12 (P=0.03), and Week 24 (P=0.09), respectively. Stabilization of distal femur fractures with periarticular locking plates can cause inconsistent and asymmetric formation of periosteal callus. A larger bridge span only minimally improves callus formation. The more flexible titanium plates enhanced callus formation compared with stainless steel plates.

  10. Autotransplantation of Mandibular Third Molar with Buccal Cortical Plate to Replace Vertically Fractured Mandibular Second Molar: A Novel Technique.

    Science.gov (United States)

    Zufía, Juan; Abella, Francesc; Trebol, Ivan; Gómez-Meda, Ramón

    2017-09-01

    Tooth replacement often leads to inadequate vertical volume in the recipient site bone when a tooth has been extracted because of a vertical root fracture (VRF). This case report presents the autotransplantation of a mandibular third molar (tooth #32) with the attached buccal cortical plate to replace a mandibular second molar (tooth #31) diagnosed with a VRF. After extraction of tooth #31, the recipient socket was prepared based on the size measured in advance with cone-beam computed tomographic imaging. The precise and calculated osteotomy of the cortical bone of tooth #32 allowed for the exact placement of the donor tooth in the position of tooth #31. The total extraoral time was only 25 minutes. The block was fixed to the recipient socket with an osteosynthesis screw and splinted with a double resin wire for 8 weeks. At the 6-month follow-up, the screw was removed, and the stability of the tooth and the regeneration obtained throughout the vestibular area were confirmed. At the 2-year follow-up, the transplanted tooth was asymptomatic and maintained a normal bone level. Advantages of autotransplantation over dental implants include maintenance of proprioception, possible orthodontic movements, and a relatively low cost. This case report demonstrates that an autotransplantation of a third molar attached to its buccal cortical plate is a viable option to replace teeth with a VRF. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  11. Miniplate for osteosynthesis in a 9-year-old with symphysis fracture: clinical report.

    Science.gov (United States)

    Srinivasan, Ila; Kumar, Naveen; Jaganathan, Udhya; Bhandari, Arihant

    2013-09-01

    Osteosynthesis using minimum material in pediatric mandibular fractures is the key, due to the limited space available in the mandible, especially in the mental foramen and apical region. There is an important role of open reduction and rigid internal fixation in re-establishing facial height, width and projection. During the early years of growth and development, there is a high osteogenic potential of the bones. The thick periosteum allows for rapid consolidation and remodeling at the site of fracture. Primary teeth have short, bulbous crowns which compromise stable maxillomandibular fixation during fracture reduction and stabilization using traditional methods. Further, stability of the fractured segments may be hampered because of the displaced or mobile permanent anterior teeth in the mixed dentition along the line of fracture. This clinical report outlines the use of miniplate with monocortical screws in a 9-year-old boy with symphysis fracture. How to cite this article: Srinivasan I, Kumar N, Jaganathan U, Bhandari A. Miniplate for Osteosynthesis in a 9-Year-Old with Symphysis Fracture: Clinical Report. Int J Clin Pediatr Dent 2013;6(3):213-216.

  12. Failure after osteosynthesis of trochanteric fractures. Where is the limit of osteoporosis?

    Science.gov (United States)

    Konstantinidis, L; Papaioannou, C; Blanke, P; Hirschmüller, A; Südkamp, N P; Helwig, P

    2013-10-01

    The aim of this study is to identify osteoporosis values, beyond which there is a high risk of osteosynthesis failure. Bone mineral density (BMD) of 30 cadaveric femora with a pertrochanteric fracture osteotomy was correlated to the risk of cut out after osteosynthesis on a biomechanical testing approach. For a BMD less than 250 mg/cm(3), there is a high risk of fixation failure after surgical treatment of pertrochanteric fractures. This value can be regarded as a reference value for future experimental and clinical studies. Despite continuous modification of intramedullary load carriers for the surgical stabilization of trochanteric fractures, cut out remains the most frequent complication. The aim of this experimental study was to identify threshold osteoporosis values, beyond which there is a high risk of osteosynthesis failure. Bone mineral density (BMD) of 30 cadaveric femora was recorded for the femoral head by QCT measurement. Subsequently, a standardized osteotomy mimicking an unstable trochanteric type fracture was stabilized by intramedullary nailing. The constructs were loaded axially at a force of 2,100 N up to 20,000 cycles. Cut out at the femoral head was documented by radiograph. Statistical evaluation of the cohort group was performed by calculation of relative risk in relation to the BMD values. In total, there were six cases of cut out after 10,000 cycles. The incidence of cut out for BMD less than 250 mg/cm(3) was 0.55 (5 of 9) and for BMD greater than 250 mg/cm(3), it was 0.05 (1 of 21). Therefore, the relative risk of cut out for BMD 250 mg/cm(3). After 20,000 cycles, an additional test caused one cut out (relative risk of cut out for a BMD fractures. Although this value is based on an experimental in vitro study design with all its associated limitations, it can be regarded as a reference value for future experimental and clinical studies.

  13. A cost-effectiveness analysis of fixed-combination therapies in patients with open-angle glaucoma: a European perspective.

    Science.gov (United States)

    Hommer, A; Wickstrøm, J; Friis, M M; Steeds, C; Thygesen, J; Ferreras, A; Gouws, P; Buchholz, P

    2008-04-01

    To compare the efficacy and cost implications of the use of the intraocular pressure-lowering prostaglandin analogues bimatoprost, travoprost, and latanoprost as fixed-combination therapies with timolol, a beta-adrenergic receptor antagonist. A decision analytic cost-effectiveness model was constructed. Since no head-to-head studies comparing the three treatment options exist, the analysis was based on an indirect comparison. Hence, the model was based on efficacy data from five randomized, controlled, clinical studies. The studies were comparable with respect to study design, time horizon, patient population and type of end point presented. The measure of effectiveness was the percentage reduction of the intraocular pressure level from baseline. The cost evaluated was the cost of medication and clinical visits to the ophthalmologist. All drug costs were market prices inclusive of value-added tax, and visit costs were priced using official physician fees. Cost-effectiveness analyses were carried out in five European countries: Spain, Italy, United Kingdom, Norway and Sweden. The time horizon for the analyses was 3 months. The analysis showed that fixed-combination bimatoprost/timolol was more effective and less costly than fixed-combination travoprost/timolol and fixed-combination latanoprost/timolol in three out of the five countries analyzed. In two countries, bimatoprost/timolol was less costly than latanoprost/timolol, and cost the same as travoprost/timolol. This cost-effectiveness analysis showed that the fixed combination of bimatoprost 0.03%/timolol 0.5% administered once daily was a cost-effective treatment option for patients with primary open-angle glaucoma. This study was limited by available clinical data: without a head-to-head trial, indirect comparisons were necessary. In the United Kingdom, Sweden, Norway, Italy, and Spain, from a health service viewpoint, bimatoprost/timolol was a slightly more effective as well as less costly treatment strategy

  14. Rib Fractures : To Fix or Not to Fix? An Evidence-Based Algorithm

    NARCIS (Netherlands)

    Bemelman, Michael; de Kruijf, M W; van Baal, Mark; Leenen, Luke

    Rib fractures are a common injury resulting from blunt chest trauma. The most important complications associated with rib fractures include death, pneumonia, and the need for mechanical ventilation. The development of new osteosynthesis materials has stimulated increased interest in the surgical

  15. Free Vibration Study of Anti-Symmetric Angle-Ply Laminated Plates under Clamped Boundary Conditions

    Science.gov (United States)

    Viswanathan, K. K.; Karthik, K.; Sanyasiraju, Y. V. S. S.; Aziz, Z. A.

    2016-11-01

    Two type of numerical approach namely, Radial Basis Function and Spline approximation, used to analyse the free vibration of anti-symmetric angle-ply laminated plates under clamped boundary conditions. The equations of motion are derived using YNS theory under first order shear deformation. By assuming the solution in separable form, coupled differential equations obtained in term of mid-plane displacement and rotational functions. The coupled differential is then approximated using Spline function and radial basis function to obtain the generalize eigenvalue problem and parametric studies are made to investigate the effect of aspect ratio, length-to-thickness ratio, number of layers, fibre orientation and material properties with respect to the frequency parameter. Some results are compared with the existing literature and other new results are given in tables and graphs.

  16. Mechanical design and analysis of focal plate for gravity deformation

    Science.gov (United States)

    Wang, Jianping; Chu, Jiaru; Hu, Hongzhuan; Li, Kexuan; Zhou, Zengxiang

    2014-07-01

    The surface accuracy of astronomical telescope focal plate is a key indicator to precision stellar observation. To conduct accurate deformation measurement for focal plate in different status, a 6-DOF hexapod platform was used for attitude adjustment. For the small adjustment range of a classic 6-DOF hexapod platform, an improved structural arrangement method was proposed in the paper to achieve ultimate adjustment of the focal plate in horizontal and vertical direction. To validate the feasibility of this method, an angle change model which used ball hinge was set up for the movement and base plate. Simulation results in MATLAB suggested that the ball hinge angle change of movement and base plate is within the range of the limiting angle in the process of the platform plate adjusting to ultimate attitude. The proposed method has some guiding significance for accurate surface measurement of focal plate.

  17. EM Scattering by a Conducting Sphere Coated with a Uniaxial Layer under Arbitrary Illumination Angle in a Fixed Laboratory Frame

    Directory of Open Access Journals (Sweden)

    C.M.Tse

    2011-12-01

    Full Text Available Under a fixed laboratory frame, the electromagnetic theory of the scattering of a plane wave of arbitrary polarizations incidence from arbitrary angles by a uniaxial anisotropic medium was obtained for the first time, and could be solved analytically from an eigensystem determined by a uniaxial anisotropic medium. By applying the boundary conditions at respective interfaces of the coated spherical structure, the unknown expansion coefficients can be obtained from the incident field and the electromagnetic fields in the anisotropic medium, and from the scattered field. Not only did the numerical results demonstrate the validity of our proposed theory but this paper shall also provide discussions in relation to some general cases (under arbitrary incident angles of bistatic radar cross section.

  18. Anterior tibial stress fractures treated with anterior tension band plating in high-performance athletes.

    Science.gov (United States)

    Cruz, Alexandre Santa; de Hollanda, João Paris Buarque; Duarte, Aires; Hungria Neto, José Soares

    2013-06-01

    The non-surgical treatment of anterior tibial cortex stress fractures requires long periods of abstention from sports activities and often results in non-union. Many different surgical techniques have already been previously described to treat these fractures, but there is no consensus on the best treatment. We describe the outcome of treatment using anterior tibial tension band plating in three high-performance athletes (4 legs) with anterior tibial cortex stress fractures. Tibial osteosynthesis with a 3.5-mm locking compression plate in the anterolateral aspect of the tibia was performed in all patients diagnosed with anterior tibial stress fracture after September 2010 at Santa Casa Hospital. All of the fractures were consolidated within a period of 3 months after surgery, allowing for an early return to pre-injury levels of competitive sports activity. There were no infection, non-union, malunion or anterior knee pain complications. Anterior tibial tension band plating leads to prompt fracture consolidation and is a good alternative for the treatment of anterior tibial cortex stress fractures. Bone grafts were shown to be unnecessary.

  19. Salvage of tibial pilon fractures using fusion of the ankle with a 90 degrees cannulated blade-plate: a preliminary report.

    Science.gov (United States)

    Morgan, S J; Thordarson, D B; Shepherd, L E

    1999-06-01

    Six patients with ankle joint destruction and delayed metaphyseal union after tibial plafond fracture were surgically treated with tibiotalar arthrodesis and metaphyseal reconstruction, using a fixed-angle cannulated blade-plate. The procedure was performed through a posterior approach in five cases and a lateral approach in one case. The subtalar joint was preserved in all cases. Metaphyseal union and a stable arthrodesis were obtained in all cases without loss of fixation and with no mechanical failure of the blade-plate. Union was obtained in an average of 26 weeks. No secondary procedures were required to obtain union. All six patients were ambulatory at last follow-up. Stable internal fixation for simultaneous tibiotalar fusion and metaphyseal reconstruction can be achieved with a cannulated blade-plate while preserving the subtalar joint in complex plafond fractures.

  20. The Golosyiv plate archive digitisation

    Science.gov (United States)

    Sergeeva, T. P.; Sergeev, A. V.; Pakuliak, L. K.; Yatsenko, A. I.

    2007-08-01

    The plate archive of the Main Astronomical Observatory of the National Academy of Sciences of Ukraine (Golosyiv, Kyiv) includes about 85 000 plates which have been taken in various observational projects during 1950-2005. Among them are about 25 000 of direct northern sky area plates and more than 600 000 plates containing stellar, planetary and active solar formations spectra. Direct plates have a limiting magnitude of 14.0-16.0 mag. Since 2002 we have been organising the storage, safeguarding, cataloguing and digitization of the plate archive. The very initial task was to create the automated system for detection of astronomical objects and phenomena, search of optical counterparts in the directions of gamma-ray bursts, research of long period, flare and other variable stars, search and rediscovery of asteroids, comets and other Solar System bodies to improve the elements of their orbits, informational support of CCD observations and space projects, etc. To provide higher efficiency of this work we have prepared computer readable catalogues and database for 250 000 direct wide field plates. Now the catalogues have been adapted to Wide Field Plate Database (WFPDB) format and integrated into this world database. The next step will be adaptation of our catalogues, database and images to standards of the IVOA. Some magnitude and positional accuracy estimations for Golosyiv archive plates have been done. The photometric characteristics of the images of NGC 6913 cluster stars on two plates of the Golosyiv's double wide angle astrograph have been determined. Very good conformity of the photometric characteristics obtained with external accuracies of 0.13 and 0.15 mag. has been found. The investigation of positional accuracy have been made with A3± format fixed bed scanner (Microtek ScanMaker 9800XL TMA). It shows that the scanner has non-detectable systematic errors on the X-axis, and errors of ± 15 μm on the Y-axis. The final positional errors are about ± 2 μm (

  1. High precision refractometry based on Fresnel diffraction from phase plates.

    Science.gov (United States)

    Tavassoly, M Taghi; Naraghi, Roxana Rezvani; Nahal, Arashmid; Hassani, Khosrow

    2012-05-01

    When a transparent plane-parallel plate is illuminated at a boundary region by a monochromatic parallel beam of light, Fresnel diffraction occurs because of the abrupt change in phase imposed by the finite change in refractive index at the plate boundary. The visibility of the diffraction fringes varies periodically with changes in incident angle. The visibility period depends on the plate thickness and the refractive indices of the plate and the surrounding medium. Plotting the phase change versus incident angle or counting the visibility repetition in an incident-angle interval provides, for a given plate thickness, the refractive index of the plate very accurately. It is shown here that the refractive index of a plate can be determined without knowing the plate thickness. Therefore, the technique can be utilized for measuring plate thickness with high precision. In addition, by installing a plate with known refractive index in a rectangular cell filled with a liquid and following the described procedures, the refractive index of the liquid is obtained. The technique is applied to measure the refractive indices of a glass slide, distilled water, and ethanol. The potential and merits of the technique are also discussed.

  2. Results of bone regenerate study after osteosynthesis with bioinert and calcium phosphate-coated bioactive implants in experimental femoral neck fractures (experimental study

    Directory of Open Access Journals (Sweden)

    K. S. Kazanin

    2015-01-01

    Full Text Available Objective - to analyze the results of X-ray, cytomorphometric and immunohistochemistry experimental studies of bone regenerates after osteosynthesis with bioinert and calcium phosphate-coated bioactive implants. Material and methods. The study was conducted on experimental femoral neck fractures in rabbit males. Reparative osteogenesis processes were studied in groups of bioinert titanium implant osteosynthesis and calcium phosphate-coated bioactive titanium implant osteosynthesis. The animals were clinically followed-up during the postoperative period. X-ray, cytomorphometric and immunohistochemistry studies of samples extracted from femoral bones were conducted over time on days 1, 7, 14, 30 and 60. The animal experiments were kept and treated according to recommendations of international standards, Helsinki Declaration on animal welfare and approved by the local ethics committee. All surgeries were performed under anesthesia, and all efforts were made to minimize the suffering of the animals. Results. In the animal group without femoral neck fracture osteosynthesis, femoral neck pseudoarthrosis was observed at the end of the experiment. The results of cytomorphometric and immunohistochemistry studies conducted on day 60 of the experiment confirmed that the cellular composition of the bone regenerate in the group of calcium phosphate-coated bioactive titanium implants corresponded to a more mature bone tissue than in the group of bioinert titanium implants. Conclusion. The results of the statistical analysis of cytomorphometric and immunohistochemistry data show that the use of calcium phosphate-coated bioactive titanium implants allows to achieve significantly earlier bone tissue regeneration.

  3. A variable angle slant-hole collimator

    International Nuclear Information System (INIS)

    Moore, R.H.; Alpert, N.M.; Strauss, H.W.

    1983-01-01

    A variable-angle slant-hole (VASH) collimator was constructed to show the feasibility of using multiple sliding plates to achieve a range of collimator channel inclinations. One hundred and sixty tungsten plates, 0.125 mm thick and 14 cm square, were photoetched to produce 3025 1.5-mm2 holes in each plate, separated by 0.8-mm septa. Along with the collimator holes, registration holes and positioning grooves were also etched. The plates were placed in a holder and stacked to form a collimator 2.0 cm high. The holder permitted the plates to be sheared to achieve viewing angles from 0 to 40 degrees from the vertical. Resolution and sensitivity were determined both across and along the shear directions. Resolution of a thin /sup 99m/Tc source, 1.24 mm diam and 7 cm long, located 5 cm from the collimator face in air, was 1.1 cm FWHM at 0 degree shear and remained unchanged with increasing slant. The resolution was similar both across and along the shear plane. Sensitivity was determined with a point source placed 7 cm from the collimator face. At 0 degree slant the sensitivity was 169 cps/MBq (6.24 csp/mu Ci). A general all purpose (GAP) collimator had a FWHM of 1 cm for the line source in air at 5 cm, and a sensitivity of 205 cps/MBq (7.58 cps/mu Ci) for the point source at 7 cm. The data suggest that a variable-angle slant-hole collimator can be constructed of laminated plates

  4. Preliminary results following the use of a fixed combination of timolol–brimonidine in patients with ocular hypertension and primary open-angle glaucoma

    Directory of Open Access Journals (Sweden)

    Dimitris Papaconstantinou

    2009-03-01

    Full Text Available Dimitris Papaconstantinou1, Ilias Georgalas2, Nikolaos Kourtis1, Christos Pitsas1, Efthimios Karmiris1, Chrysanthi Koutsandrea1, Ioannis Ladas1, Gerasimos Georgopoulos11Department of Ophthalmology, “G Gennimatas” Hospital of Athens, University of Athens, Athens, Greece; 2Department of Ophthalmology, “G Gennimatas” Hospital of Athens, NHS, Athens, Greece Purpose: The purpose of this prospective study was to evaluate the efficacy in intraocular pressure (IOP control and the tolerance of a topically administered fixed combination of timolol–brimonidine in 50 patients with ocular hypertension and primary open-angle glaucoma.Methods: After determining a baseline IOP, the fixed combination timolol–brimonidine was used twice daily for two months, while IOP, ophthalmic signs, and/or symptoms were monitored.Results: The mean IOP value was decreased from 23.09 mm Hg (±1.98 SD to 17.46 mm Hg (±1.47 SD during the 1st month (paired Student’s t test = 9.88 και p < 0.001, and to 17.51 mm Hg (±1.43 SD in the 2nd month. Between the 1st and 2nd month, no statistical difference was observed (paired Student’s t test = 0.02 και p < 0.1. In 8% of the patients during the 1st month and 10% of patients in the 2nd month, some ophthalmic signs were observed, while only mild ophthalmic symptoms were reported in 6% and 8% of the patients, respectively.Conclusions: In conclusion, the fixed combination of timolol–brimonidine has a satisfactory IOP-lowering effect without any serious side effects due to the topical use. Keywords: fixed combination 0.2% brimonidine–0.5% timolol, ocular hypertension, primary open-angle glaucoma

  5. Osteosynthesis of medial humeral epicondyle fractures in children. 8-year follow-up of 33 cases

    DEFF Research Database (Denmark)

    Duun, P S; Ravn, Pernille; Hansen, L B

    1994-01-01

    33 children with a mean age of 12 (7-15) years had open reduction and osteosynthesis for a displaced fracture of the medial humeral epicondyle. 8 (2-15) years after the operation a clinical and radiographic examination was performed. 22/33 had a prominent scar. No patients had symptoms from...

  6. Fusion peptide of influenza hemagglutinin requires a fixed angle boomerang structure for activity.

    Science.gov (United States)

    Lai, Alex L; Park, Heather; White, Judith M; Tamm, Lukas K

    2006-03-03

    The fusion peptide of influenza hemagglutinin is crucial for cell entry of this virus. Previous studies showed that this peptide adopts a boomerang-shaped structure in lipid model membranes at the pH of membrane fusion. To examine the role of the boomerang in fusion, we changed several residues proposed to stabilize the kink in this structure and measured fusion. Among these, mutants E11A and W14A expressed hemagglutinins with hemifusion and no fusion activities, and F9A and N12A had no effect on fusion, respectively. Binding enthalpies and free energies of mutant peptides to model membranes and their ability to perturb lipid bilayer structures correlated well with the fusion activities of the parent full-length molecules. The structure of W14A determined by NMR and site-directed spin labeling features a flexible kink that points out of the membrane, in sharp contrast to the more ordered boomerang of the wild-type, which points into the membrane. A specific fixed angle boomerang structure is thus required to support membrane fusion.

  7. Rapid small-angle X-ray diffraction of a tonically contracting molluscan smooth muscle recorded with imaging plates

    International Nuclear Information System (INIS)

    Tajima, Y.; Okada, K.; Yoshida, O.; Seto, T.; Amemiya, Y.

    1989-01-01

    Small-angle X-ray diffraction patterns from the anterior byssus retractor muscles of Mytilus edulis contracting tonically in response to stimulation with acetylcholine were recorded in a 30 s exposure with synchrotron radiation and a high-sensitivity X-ray area detector called an imaging plate. The 190 A layer line from the thin filaments increased in intensity with increase in tonic tension up to 6x10 4 kg m -2 . Above this value, the layer-line intensity remained almost constant and comparable to that for a contracting skeletal muscle, indicating that the same structural changes of the thin filaments occur in both muscles. (orig.)

  8. Osteosynthesis of the first phalanx fractures in horses by means of lag screws

    International Nuclear Information System (INIS)

    Bereznowski, A.; Janicki, A.M.; Sterna, J.

    1996-01-01

    Fractures of the first phalanx belong to the most frequent in horses. Three cases of surgical treatment of first phalanx fractures in horses have been presented. The cases differed by the period of time between the accident and surgical treatment. In all cases osteosynthesis by means of orthopedic screws was applied. In all horses fracture repair was successful, however, not all horses recovered fully enough to return to work. (author)

  9. Osteosynthesis techniques used for mandibular sagittal split osteotomy – history of orthognathic procedures and modern practice.

    Science.gov (United States)

    Nowak, Rafał; Trybek, Grzegorz

    Choosing an appropriate fixation technique after maxillary or mandibular osteotomy is one of the key factors affecting the success of orthognathic surgery. In line with the development of new surgical methods and techniques, the surgeons’ approach to the fixation of bone fragments has evolved accordingly, varying from non-fusion to different osteosynthesis techniques. Advances in medical sciences and medical technologies, have changed our attitudes to bone fragment reduction in orthopaedics and traumatology, and also in maxillofacial surgery. The pivotal underlying principle which determines bone healing – that is proper positioning so as to ensure appropriate contact area and immobilisation so as to ensure osteosynthesis – has remained unchanged for centuries. However, over the years, patient comfort and the predictability of treatment outcomes have vastly improved. The paper provides an overview of the techniques and methods used for the fixation of osteotomized fragments after bilateral sagittal split osteotomy since its introduction by Hugo Obwegeser up to the present day.

  10. Study of uranium plating measurement

    International Nuclear Information System (INIS)

    Lin Jufang; Wen Zhongwei; Wang Mei; Wang Dalun; Liu Rong; Jiang Li; Lu Xinxin

    2007-06-01

    In neutron physics experiments, the measurement for plate-thickness of uranium can directly affect uncertainties of experiment results. To measure the plate-thickness of transform target (enriched uranium plating and depleted uranium plating), the back to back ionization chamber, small solid angle device and Au-Si surface barrier semi-conductor, were used in the experiment study. Also, the uncertainties in the experiment were analyzed. Because the inhomo-geneous of uranium lay of plate can quantitively affect the result, the homogeneity of uranium lay is checked, the experiment result reflects the homogeneity of uranium lay is good. (authors)

  11. Heat transfer and pressure drop characteristics of a plate heat exchanger using water based Al2O3 nanofluid for 30° and 60° chevron angles

    Science.gov (United States)

    Elias, M. M.; Saidur, R.; Ben-Mansour, R.; Hepbasli, A.; Rahim, N. A.; Jesbains, K.

    2018-04-01

    Nanofluid is a new class of engineering fluid that has good heat transfer characteristics which is essential to increase the heat transfer performance in various engineering applications such as heat exchangers and cooling of electronics. In this study, experiments were conducted to compare the heat transfer performance and pressure drop characteristics in a plate heat exchanger (PHE) for 30° and 60° chevron angles using water based Al2O3 nanofluid at the concentrations from 0 to 0.5 vol.% for different Reynolds numbers. The thermo-physical properties has been determined and presented in this paper. At 0.5 vol% concentration, the maximum heat transfer coefficient, the overall heat transfer coefficient and the heat transfer rate for 60° chevron angle have attained a higher percentage of 15.14%, 7.8% and 15.4%, respectively in comparison with the base fluid. Consequently, when the volume concentration or Reynolds number increases, the heat transfer coefficient and the overall heat transfer coefficient as well as the heat transfer rate of the PHE (Plate Heat Exchangers) increases respectively. Similarly, the pressure drop increases with the volume concentration. 60° chevron angle showed better performance in comparison with 30° chevron angle.

  12. A fixed angle double mirror filter for preparing a pink undulator beam at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Dufresne, E.; Sanchez, T.; Nurushev, T.; Clarke, R.; Dierker, S.B.

    2000-01-01

    Recent advances in X-ray Photon Correlation Spectroscopy (XPCS) use the full bandwidth of an undulator harmonic in order to maximize the coherent flux for small angle X-ray scattering experiments. X-ray mirrors and filters are typically used to select a given harmonic of the spectrum. At the University of Michigan/Howard University/Lucent Technologies, Bell Labs, Collaborative Access Team (MHATT-CAT) undulator beamline of the Advanced Photon Source, we have designed a fixed-angle Double Mirror Filter which will provide a 'pink beam' (i.e., 2-3% bandwidth) for XPCS experiments. This device uses two small mirrors which vertically reflect a 0.1 mmx0.1 mm white beam in a symmetric geometry. The doubly reflected beam propagates parallel to the incident white beam, but is offset vertically by 35 mm. Using the standard offset of the APS allows one to stop the white beam with a standard APS beam stop. In this report, we will describe our design considerations for this instrument. We also report the results of preliminary tests of the performance. The mirrors preserve the transverse coherence of the source, and filter the undulator spectrum as expected

  13. PIV-based estimation of unsteady loads on a flat plate at high angle of attack using momentum equation approaches

    Science.gov (United States)

    Guissart, A.; Bernal, L. P.; Dimitriadis, G.; Terrapon, V. E.

    2017-05-01

    This work presents, compares and discusses results obtained with two indirect methods for the calculation of aerodynamic forces and pitching moment from 2D Particle Image Velocimetry (PIV) measurements. Both methodologies are based on the formulations of the momentum balance: the integral Navier-Stokes equations and the "flux equation" proposed by Noca et al. (J Fluids Struct 13(5):551-578, 1999), which has been extended to the computation of moments. The indirect methods are applied to spatio-temporal data for different separated flows around a plate with a 16:1 chord-to-thickness ratio. Experimental data are obtained in a water channel for both a plate undergoing a large amplitude imposed pitching motion and a static plate at high angle of attack. In addition to PIV data, direct measurements of aerodynamic loads are carried out to assess the quality of the indirect calculations. It is found that indirect methods are able to compute the mean and the temporal evolution of the loads for two-dimensional flows with a reasonable accuracy. Nonetheless, both methodologies are noise sensitive, and the parameters impacting the computation should thus be chosen carefully. It is also shown that results can be improved through the use of dynamic mode decomposition (DMD) as a pre-processing step.

  14. Outcome of Distal Both Bone Leg Fractures Fixed by Intramedulary Nail for Fibula & MIPPO in Tibia.

    Science.gov (United States)

    Gupta, Anil; Anjum, Rashid; Singh, Navdeep; Hackla, Shafiq

    2015-04-01

    Fractures of the distal third of the tibia are mostly associated with a fibular fracture that often requires fixation. The preferred treatment of distal tibial fracture is the minimally invasive percutaneous plate osteosynthesis (MIPPO) procedure. However, there are no clear cut guidelines on fixation of the fibular fracture and currently most orthopedic surgeons use a plate osteosynthesis for the fibula as well. A common complication associated with dual plating is an increased chance of soft tissue necrosis, infection, and in some cases resulting in an exposed implant. We conducted a prospective study to analyze the results of fractures of the distal in both leg bones managed by the MIPPO procedure for tibial fractures and a rush nail for fibular fractures. The study was conducted in a tertiary care hospital from November 2012 to May 2014, a total of 30 fractures in 30 patients (18 males, 12 females) with a mean age of 42.4 years (26-60 years) were treated in our institution in the aforesaid time period with MIPPO for tibia and rush nail for fibular fractures. All the cases were operated on by a single surgeon in emergency within 24 hours. The patients with skin blistering and compound fractures were excluded from this study. Rehabilitative measures were proceeded as per patient's pain profile, isometric and isotonic exercises were started on the first post-operative day, with full weight bearing at 10-12 weeks after assessing clinical and radiological union. Regular follow up of patients was done, radiographs were taken at the immediate post-operative period and at 3, 6, 12 and 24 weeks. All the patients were available for regular follow up. Radiological and clinical union proceeded normally in all the patients, no patients had signs of any deep infection, delayed union or nonunion, three patients had a superficial infection of the tibial incision that healed with a change in antibiotic. The use of dual plating for fixation of the lower tibia and fibula

  15. A tandem parallel plate analyzer

    International Nuclear Information System (INIS)

    Hamada, Y.; Fujisawa, A.; Iguchi, H.; Nishizawa, A.; Kawasumi, Y.

    1996-11-01

    By a new modification of a parallel plate analyzer the second-order focus is obtained in an arbitrary injection angle. This kind of an analyzer with a small injection angle will have an advantage of small operational voltage, compared to the Proca and Green analyzer where the injection angle is 30 degrees. Thus, the newly proposed analyzer will be very useful for the precise energy measurement of high energy particles in MeV range. (author)

  16. Sustained relief of pain from osteosynthesis surgery of rib fracture by using biodegradable lidocaine-eluting nanofibrous membranes.

    Science.gov (United States)

    Yu, Yi-Hsun; Hsu, Yung-Heng; Chou, Ying-Chao; Fan, Chin-Lung; Ueng, Steve W N; Kau, Yi-Chuan; Liu, Shih-Jung

    2016-10-01

    Various effective methods are available for perioperative pain control in osteosynthesis surgery, but they are seldom applied intraoperatively. The aim of this study was to evaluate a biodegradable poly([d,l]-lactide-co-glycolide) (PLGA)/lidocaine nanofibrous membrane for perioperative pain control in rib fracture surgery. Scanning electron microscopy showed high porosity of the membrane, and an ex vivo high-performance liquid chromatography study revealed an excellent release profile for both burst and controlled release of lidocaine within 30days. Additionally, the PLGA/lidocaine nanofibrous membrane was applied in an experimental rabbit rib osteotomy model. Implantation of the membrane around the osteotomized rib during osteosynthesis surgery resulted in a significant increase in weight gain, food and water consumption, and daily activity compared to the study group without the membrane. In addition, all osteotomized ribs were united. Thus, application of the PLGA/lidocaine nanofibrous membrane may be effective for sustained relief of pain in oeteosynthesis surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Degradation behaviour of LAE442-based plate-screw-systems in an in vitro bone model.

    Science.gov (United States)

    Wolters, Leonie; Besdo, Silke; Angrisani, Nina; Wriggers, Peter; Hering, Britta; Seitz, Jan-Marten; Reifenrath, Janin

    2015-04-01

    The use of absorbable implant materials for fixation after bone fracture helps to avoid a second surgery for implant removal and the risks and costs involved. Magnesium (Mg) is well known as a potential metallic material for degradable implants. The aim of the present in vitro study was to evaluate if degradable LAE442-based magnesium plate-screw-systems are suitable candidates for osteosynthesis implants in load-bearing bones. The corrosion behaviour was tested concerning the influence of different surface treatments, coatings and screw torques. Steel plates and screws of the same size served as control. Plates without special treatment screwed on up to a specified torque of 15cNm or 7cNm, NaOH treated plates (15cNm), magnesium fluoride coated plates (15cNm) and steel plates as control (15cNm) were examined in pH-buffered, temperature-controlled SBF solution for two weeks. The experimental results indicate that the LAE442 plates and screws coated with magnesium fluoride revealed a lower hydrogen evolution in SBF solution as well as a lower weight loss and volume decrease in μ-computed tomography (μCT). The nanoindentation and SEM/EDX measurements at several plate areas showed no significant differences. Summarized, the different screw torques did not affect the corrosion behaviour differently. Also the NaOH treatment seemed to have no essential influence on the degradation kinetics. The plates coated with magnesium fluoride showed a decreased corrosion rate. Hence, it is recommended to consider this coating for the next in vivo study. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Anatomical evidence for the anterior plate fixation of sacroiliac joint.

    Science.gov (United States)

    Bai, Zhibiao; Gao, Shichang; Liu, Jia; Liang, Anlin; Yu, Weihua

    2018-01-01

    The iatrogenic injuries to the lumbar nerves during the fixation the sacroiliac (SI) joint fractures with anterior plates were often reported. No specific method had been reported to avoid it. This study was done to find a safer way of placing the anterior plates and screws for treating the sacroiliac (SI) joint fracture and/or dislocation. The research was performed using 8 male and 7 female normal corpse pelvic specimens preserved by 10% formalin solution. Try by measuring the horizontal distance from L4, L5 nerve roots to the sacroiliac joint and perpendicular distance from L4, L5 nerve roots to the ala sacralis, the length of L4, L5 nerve roots from intervertebral foramen to the edge of true pelvis, the diameter of L4, L5 nerve roots. The angles between the sacroiliac joint and sagittal plane were measured on the CT images. The horizontal distance between the lateral side of the anterior branches of L4, L5 nerve roots and the sacroiliac joint decreased gradually from the top to the bottom. The widest distances for L4,5 were 2.1 cm (range, 1.74-2.40) and 2.7 cm (range, 2.34-3.02 cm), respectively. The smallest distances for L4, 5 were 1.2 cm (range, 0.82-1.48 cm) and 1.5 cm (range, 1.08-1.74 cm), respectively. On CT images, the angle between the sacroiliac joint and sagittal plane was about 30°. If we use two anterior plates to fix the sacroiliac joint, It is recommended to place one plate on the superior one third part of the joint, with exposing medially no more than 2.5 cm and the other in the middle one third part of the joint, with elevating periosteum medially no more than 1.5 cm. The screws in the sacrum are advised to incline medially about 30° directing to the true pelvis. Copyright © 2017. Published by Elsevier B.V.

  19. Impact of deep sternal wound infection management with vacuum-assisted closure therapy followed by sternal osteosynthesis: a 15-year review of 23,499 sternotomies.

    Science.gov (United States)

    Baillot, Richard; Cloutier, Daniel; Montalin, Livia; Côté, Louise; Lellouche, François; Houde, Chanel; Gaudreau, Geneviève; Voisine, Pierre

    2010-04-01

    This study was undertaken to examine the outcome of patients with deep sternal wound infection (DSWI) now treated with vacuum-assisted closure (VAC) therapy as a bridge to sternal osteosynthesis with horizontal titanium plate fixation. From 1992 to 2007, a consecutive cohort of 23,499 patients underwent open-heart surgery (OHS) in our institution. The period under study was divided in two according to the use of therapeutic modalities: conventional (1992-2001, N=118 DSWI): debridement/drainage with primary closure and irrigation (N=37), debridement/drainage, open packing followed by pectoralis myocutaneous flaps (PMFs) (N=81); contemporary (2002-2007, N=149 DSWI): conventional treatment (N=24) and VAC therapy (N=125/83.8%). VAC was followed by sternal osteosynthesis with horizontal titanium plates in 92 patients (61.7%). DSWI was diagnosed in 267 out of 23 499 (1.1%) patients of our entire series according to Center for Disease Control - Atlanta (CDC) criteria, 118 out of 13 180 (0.9%) in the first and 149 out of 10 319 (1.4%) in the second period (p=0.001). Hospital mortality (N=267/23,499) has been 10.25% for the entire cohort under study without any difference between groups (1992-2001: 11.4%; 2002-2007: 9.1%, p=0.67). More recently, VAC therapy (N=125) was associated with a lower mortality (4.8% vs 14.1%, p=0.01). Stepwise multivariable logistic regression analysis for both periods revealed that prolonged intubation in the intensive care unit (ICU), use of bilateral internal thoracic artery grafting (BIMA), diabetes, re-operation for bleeding and body mass index (BMI) >30 kgm(-2) are the most powerful predictors of DSWI. In the more recently treated patients using VAC therapy, combined procedures (valve and graft) also emerged as a significant predictor. For the entire study, Staphylococcus epidermidis (49.6%) has been the most frequently identified pathogen, followed by Staphylococcus aureus (38.8%). Methicillin-resistant S.aureus (MRSA) was observed in 4

  20. Bipolar fracture dislocation of clavicle: A report of osteosynthesis and early soft tissue reconstruction

    Directory of Open Access Journals (Sweden)

    Renaldi Prasetia

    Full Text Available Introduction: Bipolar dislocation of the clavicle, also called bifocal or pan-articular dislocation or floating clavicle, is an uncommon traumatic injury. The injury of this case is also concomitant with distal third clavicle and coracoid fracture. This article aimed to report the experience of performing osteosynthesis and early soft tissue reconstruction on these injuries. Case report: We reported a case of bipolar clavicle fracture-dislocation in concomitant with coracoid fracture in a man, aged 32 years old, successfully treated 24 days after accident by fixation of both fractures and early simultaneous reconstruction of sternoclavicular- acromioclavicular-coracoclavicular joints. Discussion: These injuries are rare and capable of causing many complications if they are treated improperly. It is compulsory to carefully assess any fractured clavicle along its whole length, both clinically and radiologically. Various options, from non-operative to operative, have been reported to manage such of these cases. Early bony fixation and soft tissue reconstruction can correct the alignment of clavicle and recover the function of sterno-clavicular and acromio-clavicular- joints promptly. Conclusion: Fracture osteosynthesis and early soft tissue reconstruction can be regarded as an option treatment for bipolar fracture-dislocation of the clavicle to facilitate prompt treatment and early rehabilitation. Keywords: Bipolar dislocation, Floating clavicle, Early reconstruction, Soft tissue reconstruction

  1. Bipolar fracture dislocation of clavicle: A report of osteosynthesis and early soft tissue reconstruction.

    Science.gov (United States)

    Prasetia, Renaldi; Rasyid, Hermawan Nagar

    2017-01-01

    Bipolar dislocation of the clavicle, also called bifocal or pan-articular dislocation or floating clavicle, is an uncommon traumatic injury. The injury of this case is also concomitant with distal third clavicle and coracoid fracture. This article aimed to report the experience of performing osteosynthesis and early soft tissue reconstruction on these injuries. We reported a case of bipolar clavicle fracture-dislocation in concomitant with coracoid fracture in a man, aged 32 years old, successfully treated 24days after accident by fixation of both fractures and early simultaneous reconstruction of sternoclavicular- acromioclavicular-coracoclavicular joints. These injuries are rare and capable of causing many complications if they are treated improperly. It is compulsory to carefully assess any fractured clavicle along its whole length, both clinically and radiologically. Various options, from non-operative to operative, have been reported to manage such of these cases. Early bony fixation and soft tissue reconstruction can correct the alignment of clavicle and recover the function of sterno-clavicular and acromio-clavicular- joints promptly. Fracture osteosynthesis and early soft tissue reconstruction can be regarded as an option treatment for bipolar fracture-dislocation of the clavicle to facilitate prompt treatment and early rehabilitation. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  2. New Tests of the Fixed Hotspot Approximation

    Science.gov (United States)

    Gordon, R. G.; Andrews, D. L.; Horner-Johnson, B. C.; Kumar, R. R.

    2005-05-01

    We present new methods for estimating uncertainties in plate reconstructions relative to the hotspots and new tests of the fixed hotspot approximation. We find no significant motion between Pacific hotspots, on the one hand, and Indo-Atlantic hotspots, on the other, for the past ~ 50 Myr, but large and significant apparent motion before 50 Ma. Whether this motion is truly due to motion between hotspots or alternatively due to flaws in the global plate motion circuit can be tested with paleomagnetic data. These tests give results consistent with the fixed hotspot approximation and indicate significant misfits when a relative plate motion circuit through Antarctica is employed for times before 50 Ma. If all of the misfit to the global plate motion circuit is due to motion between East and West Antarctica, then that motion is 800 ± 500 km near the Ross Sea Embayment and progressively less along the Trans-Antarctic Mountains toward the Weddell Sea. Further paleomagnetic tests of the fixed hotspot approximation can be made. Cenozoic and Cretaceous paleomagnetic data from the Pacific plate, along with reconstructions of the Pacific plate relative to the hotspots, can be used to estimate an apparent polar wander (APW) path of Pacific hotspots. An APW path of Indo-Atlantic hotspots can be similarly estimated (e.g. Besse & Courtillot 2002). If both paths diverge in similar ways from the north pole of the hotspot reference frame, it would indicate that the hotspots have moved in unison relative to the spin axis, which may be attributed to true polar wander. If the two paths diverge from one another, motion between Pacific hotspots and Indo-Atlantic hotspots would be indicated. The general agreement of the two paths shows that the former is more important than the latter. The data require little or no motion between groups of hotspots, but up to ~10 mm/yr of motion is allowed within uncertainties. The results disagree, in particular, with the recent extreme interpretation of

  3. Comparison of the Resistance to Bending Forces of the 4.5 LCP Plate-rod Construct and of 4.5 LCP Alone Applied to Segmental Femoral Defects in Miniature Pigs

    Directory of Open Access Journals (Sweden)

    Lucie Urbanová

    2010-01-01

    Full Text Available The study deals with the determination of mechanical properties, namely resistance to bending forces, of flexible buttress osteosynthesis using two different bone-implant constructs stabilizing experimental segmental femoral bone defects (segmental ostectomy in a miniature pig ex vivo model using 4.5 mm titanium LCP and a 3 mm intramedullary pin (“plate and rod” construct (PR-LCP, versus the 4.5 mm titanium LCP alone (A-LCP. The “plate and rod” fixation (PR-LCP of the segmental femoral defect is significantly more resistant (p in vivo experiments in the miniature pig to investigate bone defect healing after transplantation of mesenchymal stem cells in combination with biocompatible scaffolds.

  4. Internal fixation of mandibular angle fractures: a meta-analysis.

    Science.gov (United States)

    Regev, Eran; Shiff, Jacob S; Kiss, Alex; Fialkov, Jeffrey A

    2010-06-01

    The degree of rigidity of internal fixation required for the treatment of mandibular angle fractures has long been at the center of debate in the literature. A statistical comparison between rigid fixation and monocortical fixation has been difficult because of multiple terms, definitions, and technical variations. The purpose of this study was to use the meta-analysis tool to combine information from multiple studies and to compare complication rates for different fixation methods. An English language literature search was conducted for articles on mandibular angle fractures. Information was collected on four variables of interest: compression/noncompression technique, monocortical/bicortical screws, number of plates, and location of plates. Five outcome rates were analyzed: infection, reoperation, hardware removal, malunion, and nonunion. Meta-analyses were run using Comprehensive Meta Analysis, version 2.2.03. Twenty-four studies with relevant data on the variables and outcomes of interest met the inclusion criteria. Significantly higher rates of infection, reoperation, and hardware removal were found for compression compared with noncompression, two plates compared with one plate, and for plates located on both the inferior and superior borders as compared with superior or inferior only. There were also significantly higher infection rates for bicortical screws compared with monocortical screws and higher malunion rates for compression compared with noncompression plating techniques. The results of this meta-analysis found lower complication rates with the use of noncompression, monocortical, and single-plate fixation, supporting the trend toward a single, superiorly placed, monocortical miniplate for fixation of mandibular angle fractures.

  5. Failure analysis of stainless steel femur fixation plate.

    Science.gov (United States)

    Hussain, P B; Mohammad, M

    2004-05-01

    Failure analysis was performed to investigate the failure of the femur fixation plate which was previously fixed on the femur of a girl. Radiography, metallography, fractography and mechanical testing were conducted in this study. The results show that the failure was due to the formation of notches on the femur plate. These notches act as stress raisers from where the cracks start to propagate. Finally fracture occurred on the femur plate and subsequently, the plate failed.

  6. Assessment of bone healing on tibial fractures treated with wire osteosynthesis associated or not with infrared laser light and biphasic ceramic bone graft (HATCP) and guided bone regeneration (GBR): Raman spectroscopy study

    Science.gov (United States)

    Bastos de Carvalho, Fabíola; Aciole, Gilberth Tadeu S.; Aciole, Jouber Mateus S.; Silveira, Landulfo, Jr.; Nunes dos Santos, Jean; Pinheiro, Antônio L. B.

    2011-03-01

    The aim of this study was to evaluate, through Raman spectroscopy, the repair of complete tibial fracture in rabbits fixed with wire osteosynthesis - WO, treated or not with infrared laser light (λ 780nm, 50mW, CW) associated or not to the use of HATCP and GBR. Surgical fractures were created under general anesthesia (Ketamine 0.4ml/Kg IP and Xilazine 0.2ml/Kg IP), on the tibia of 15 rabbits that were divided into 5 groups and maintained on individual cages, at day/night cycle, fed with solid laboratory pelted diet and had water ad libidum. On groups II, III, IV and V the fracture was fixed with WO. Animals of groups III and V were grafted with hydroxyapatite + GBR technique. Animals of groups IV and V were irradiated at every other day during two weeks (16J/cm2, 4 x 4J/cm2). Observation time was that of 30 days. After animal death the specimens were kept in liquid nitrogen for further analysis by Raman spectroscopy. Raman spectroscopy showed significant differences between groups (phydroxyapatite.

  7. Distal tibial fracture treated by minimally invasive plate osteosynthesis after external fixation Retrospective clinical and radiographic assessment

    Directory of Open Access Journals (Sweden)

    Al. Șerban

    2014-02-01

    Full Text Available Fractures of the horizontal surface of the distal tibia are known commonly as pylon or plafond fractures, and represent 1-5% of lower extremity fractures, 7-10% of all tibial fractures. The protocol consisted of immediate (within eight to 24 hours open reduction and internal fixation of the fibula, using a fibular plate or one third tubular plate and application of an external fixator spanning the ankle joint. In the second stage, the treatment of proximal and distal tibial fractures with close reduction and MIPPO technique can preserve soft tissue, simplify operative procedure and decrease wound, obtain rigid internal fixation and guarantee early function exercises of ankle joint. In this study we evaluated 22 patients treated in Clinical Emergency Hospital Constanta between April 2012 - July 2013 diagnosed with multifragmentary fractures of the distal tibia. This study evaluates the treatment of complex fractures of distal tibia with locked plate after external fixation. There were 17 males and 5 females of mean age 51,7 years (31-68. The mean follow-up period was 14 weeks. (Ranging from 9-16 weeks. All patients were fully weight bearing at 16 weeks (ranging 9-16 weeks showing radiological union. There were no cases of failures of fixation, or rotational misalignment. No significant complication was observed in our patients. MIPO is an effective method of treatment for distal tibial fractures, reduce surgical trauma and maintain a more biologically favorable environment for fracture healing, reducing risks of infection and nonunion.

  8. Clinical effectiveness of brinzolamide 1%–brimonidine 0.2% fixed combination for primary open-angle glaucoma and ocular hypertension

    Directory of Open Access Journals (Sweden)

    Sharma S

    2015-11-01

    Full Text Available Sourabh Sharma,1 Sameer Trikha,1 Shamira A Perera,1 Tin Aung1,2 1Glaucoma Department, Singapore Eye Research Institute, Singapore National Eye Centre, 2Department of Ophthalmology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore Abstract: The main first-line treatment strategy for glaucoma is to reduce intraocular pressure (IOP by topical ocular hypotensive medications, but many patients require multiple medications for adequate IOP control. Fixed-combination therapies provide several benefits, including simplified treatment regimens, theoretical improved treatment adherence, elimination of the potential for washout of the first drug by the second, and the reduction in ocular exposure to preservatives. β-Adrenoceptor antagonists (particularly 0.5% timolol are the most commonly used agents in combination with other classes of drugs as fixed-combination eyedrops, but they are contraindicated in many patients, owing to local allergy or systemic side effects. A fixed-combination preparation without a β-blocker is therefore warranted. This paper reviews the clinical effectiveness of brinzolamide 1% and brimonidine 0.2% fixed combination (BBFC for use in patients with primary open-angle glaucoma and ocular hypertension. We searched PubMed and the ClinicalTrials.gov registry, and identified three randomized controlled trials comparing BBFC vs its constituents (brimonidine vs brinzolamide, and one comparing BBFC with unfixed brimonidine and brinzolamide. All of the studies demonstrated mean diurnal IOP to be statistically significantly lower in the BBFC group compared with constituent groups and noninferior to that with the concomitant group using two separate bottles. The safety profile of BBFC was consistent with that of its individual components, the most common ocular adverse events being ocular hyperemia, visual disturbances, and ocular allergic reactions. Common systemic adverse effects included altered taste

  9. Efficacy and safety of benzalkonium chloride-free fixed-dose combination of latanoprost and timolol in patients with open-angle glaucoma or ocular hypertension

    Directory of Open Access Journals (Sweden)

    Bhagat P

    2014-06-01

    Full Text Available Purvi Bhagat,1 Kalyani Sodimalla,2 Chandrima Paul,3 Surinder S Pandav,4 Ganesh V Raman,5 Rengappa Ramakrishnan,6 Abhijeet Joshi,7 Atul Raut7 1Glaucoma Clinic, M & J Western Regional Institute of Ophthalmology, Civil Hospital, Ahmedabad, Gujarat, India; 2Glaucoma Department, PBMA’s H.V. Desai Eye Hospital, Maharashtra, India; 3Glaucoma Service, B B Eye Foundation, Kolkata, India; 4Advanced Eye Centre, Postgraduate Institute of Medical Education and Research, Chandigarh, India; 5Glaucoma Clinic, Aravind Eye Hospital, Coimbatore, Tamilnadu, India; 6Glaucoma Clinic, Aravind Eye Hospital, Tirunelveli, Tamilnadu, India; 7Clinical Research Department, Sun Pharma Advanced Research Company Ltd, Mumbai, Maharashtra, India Background: Benzalkonium chloride (BAK is a common preservative in topical ocular preparations; however, prolonged use may lead to deleterious effects on the ocular surface, affecting quality of life and reducing adherence to treatment and overall outcomes. This study compared the intraocular pressure (IOP-lowering efficacy and safety of a novel once-daily, BAK-free, fixed-dose combination of latanoprost plus timolol with latanoprost or timolol administered as monotherapy or concomitantly. Methods: This was a 6-week, randomized, open-label, parallel-group, active-controlled study in patients aged ≥18 years with open-angle glaucoma or ocular hypertension. A total of 227 patients were randomized to either a once-daily, BAK-free, fixed-dose combination of latanoprost 0.005%/timolol 0.5% ophthalmic solution or concomitant administration of once-daily latanoprost 0.005% plus twice-daily timolol 0.5% or once-daily latanoprost 0.005% monotherapy, or twice-daily timolol 0.5% monotherapy. Efficacy end points were assessed at three time points on visits at weeks 1, 2, 4, and 6 versus baseline. Results: The IOP-lowering efficacy of the fixed-dose combination of latanoprost/timolol was similar to that of latanoprost plus timolol administered

  10. Influence of Different Diffuser Angle on Sedan's Aerodynamic Characteristics

    Science.gov (United States)

    Hu, Xingjun; Zhang, Rui; Ye, Jian; Yan, Xu; Zhao, Zhiming

    The aerodynamic characteristics have a great influence on the fuel economics and the steering stability of a high speed vehicle. The underbody rear diffuser is one of important aerodynamic add-on devices. The parameters of the diffuser, including the diffuser angle, the number and the shape of separators, the shape of the end plate and etc, will affect the underbody flow and the wake. Here, just the influence of the diffuser angle was investigated without separator and the end plate. The method of Computational Fluid Dynamics was adopted to study the aerodynamic characteristics of a simplified sedan with a different diffuser angle respectively. The diffuser angle was set to 0°, 3°, 6°, 9.8° and 12° respectively. The diffuser angle of the original model is 9.8°. The conclusions were drawn that when the diffuser angle increases, the underbody flow and especially the wake change greatly and the pressure change correspondingly; as a result, the total aerodynamic drag coefficients of car first decrease and then increases, while the total aerodynamic lift coefficients decrease.

  11. [Experimental study on carbon fiber reinforced plastic plate--analysis of stabilizing force required for plate].

    Science.gov (United States)

    Iizuka, H

    1990-11-01

    Plates currently in use for the management of bone fracture made of metal present with various problems. We manufactured carbon fiber reinforced plastic (CFRP) plates from Pyrofil T/530 puriplegs overlaid at cross angles of +/- 10 degrees, +/- 20 degrees, and +/- 30 degrees for trial and carried out an experimental study on rabbit tibiofibular bones using 316L stainless steel plates of comparable shape and size as controls. The results indicate the influence of CFRP plate upon cortical bone was milder than that of stainless steel plate, with an adequate stabilizing force for the repair of fractured rabbit tibiofibular bones. CFRP has the advantages over metals of being virtually free from corrosion and fatigue, reasonably radiolucent and able to meet a wide range of mechanical requirements. This would make CFRP plate quite promising as a new devices of treating fracture of bones.

  12. Fixed combination of bimatoprost and timolol in patients with primary open-angle glaucoma or ocular hypertension with inadequate IOP adjustment

    Directory of Open Access Journals (Sweden)

    Gerrett Brief

    2010-09-01

    Full Text Available Gerrett Brief1, Tobias Lammich2, Edgar Nagel3, Sabine Pfennigsdorf4, Christoph W Spraul5, Selwyn Ho61Facharzt für Augenheilkunde, Dortmund, Germany; 2Neubrandenburg, Germany; 3Augenarztpraxis Rudolstadt, Germany; 4Polch, Germany; 5Geiselhart, Ulm, Germany; 6Allergan Europe, Marlow, UKObjective: To assess the efficacy and tolerability of a fixed combination of bimatoprost and timolol (BTFC in a large patient sample in a clinical setting.Methods: In this multicenter, observational, noncontrolled, open-label study, patients (n = 1862 with primary open-angle glaucoma or ocular hypertension were treated with BTFC. Assessments were made at baseline, six weeks, and three months.Results: Prior to starting BTFC, 92.3% of patients were taking other ocular hypotensive medications. In the overall group at three months, mean intraocular pressure was reduced from baseline (21.7 ± 4.5 mmHg and 21.8 ± 4.9 mmHg for the right and left eye, respectively to 16.1 ± 3.0 mmHg for each eye (P < 0.0001. The majority of patients (92% reported no adverse events. The most commonly reported adverse events (in >1% of patients were eye irritation, and ocular and conjunctival hyperemia. Adherence to treatment was generally better than (35.4% or the same as (57.5% with prior therapy. BTFC tolerability was rated as excellent or good by 92.3% of physicians and 85.8% of patients.Conclusions: In a large group of patients with primary open-angle glaucoma or ocular hypertension, treatment with BTFC was associated with consistent reductions in IOP, improved adherence to treatment, and good tolerability.Keywords: bimatoprost, timolol, intraocular pressure, fixed combination, glaucoma

  13. [Direct osteosynthesis of instable Gehweiler Type III atlas fractures. Presentation of a dorsoventral osteosynthesis of instable atlas fractures while maintaining function].

    Science.gov (United States)

    Böhm, H; Kayser, R; El Saghir, H; Heyde, C-E

    2006-09-01

    This retrospective study evaluates eight patients with unstable fractures of the atlas vertebra, treated operatively in the Central Clinic Bad Berka between January 1995 and December 2001. In all cases, we were confronted with unstable and dislocated type III fractures according to Gehweiler, caused by an injured transverse ligament. Mean age was 34 years (range 20-49) in two women and six men. We introduce a new technique of direct reconstruction of the atlas vertebra. This technique leads to a stable ring construct that allows compression osteosynthesis of the fracture. Spinal fusion can be avoided, as can postoperative immobilization, since sufficient stability for functional postoperative treatment is achievable. The follow-up control 38 months (range 6-75) after surgery showed solid bony fusion in all cases, in one case after revision surgery. All patients showed good functional results, there was no need for analgesics and all patients could be reintegrated into their former occupation.

  14. Aerodynamic drag reduction by vertical splitter plates

    Science.gov (United States)

    Gilliéron, Patrick; Kourta, Azeddine

    2010-01-01

    The capacity of vertical splitter plates placed at the front or the rear of a simplified car geometry to reduce drag, with and without skew angle, is investigated for Reynolds numbers between 1.0 × 106 and 1.6 × 106. The geometry used is a simplified geometry to represent estate-type vehicles, for the rear section, and MPV-type vehicle. Drag reductions of nearly 28% were obtained for a zero skew angle with splitter plates placed at the front of models of MPV or utility vehicles. The results demonstrate the advantage of adapting the position and orientation of the splitter plates in the presence of a lateral wind. All these results confirm the advantage of this type of solution, and suggest that this expertise should be used in the automotive field to reduce consumption and improve dynamic stability of road vehicles.

  15. Development of an angle-scanning spectropolarimeter: Preliminary results

    Science.gov (United States)

    Nouri, Sahar A.; Gregory, Don A.; Fuller, Kirk

    2018-02-01

    A fixed-angle spectropolarimeter capable of measuring the Mueller matrix of particle deposits and conventional optical elements over the 300-1100 nm spectral range has been built, calibrated and extensively tested. A second generation of this instrument is being built which can scan from 0° to near 180° in both scattering angle and sample orientation, enabling studies of the bidirectional Mueller matrices of nanoparticle arrays, atmospheric aerosol deposits, and nano- and microstructured surfaces. This system will also provide a much needed metrology capability for fully characterizing the performance of optical devices and device components from the near-infrared through the medium wave ultraviolet. Experimental results taken using the first generation fixed-angle arrangement will be presented along with the rationale for building the second.

  16. An investigation of coated aluminium bipolar plates for PEMFC

    International Nuclear Information System (INIS)

    Lin, Chien-Hung; Tsai, Sung-Ying

    2012-01-01

    Highlights: ► Coated aluminium bipolar plates demonstrate the hydrophobic property than the raw material. ► The corrosion behaviour of bipolar plate decreases the PEMFC performance severely. ► These PEMFCs are measured by current–voltage (I–V) curve test. ► The oxide film increases the interfacial contact resistance. -- Abstract: The performance of Al-alloy bipolar plates for the PEMFC (proton exchange membrane fuel cell) system is investigated in this paper. The metallic bipolar plates are modified with a Ni–P coating. The performance of the Al-alloy bipolar plates is evaluated by the coating structure, corrosion resistance, contact angle and single cell performance. The results indicate that the coated aluminium bipolar plates demonstrate hydrophobic and anti-corrosive properties. The hydrophobic property increases the contact angle on the surface from 46.08° to 80.51°. Meanwhile, the corrosion rate of the Ni–P coating can be over 1 order of magnitude lower than that of the substrate. Hence, the substrate with the coating maintains superior performance under the long term test. The present study proves that both the hydrophobicity and corrosion resistance significantly affect the metallic bipolar plate.

  17. Growth plate closure: Apex view on bone scan

    International Nuclear Information System (INIS)

    Giles, P.H.; Trochei, M.; Yeates, K.

    1984-01-01

    Angular deformities of the extremities in children following premature closure of the growth plate are well known. The deformities depend on the position of an osseus bridge which forms between the epiphysis and metaphysis. Several surgical procedures including resection of the osseus bridge have been described, however, delineation of the site of fusion is difficult to define. The commonest site of growth plate arrest is the distal femoral or proximal tibial growth plate. A new technique using the bone scan has been developed which accurately defines the area and position of these osseus bridges. Two hours after injection of technetium 99m methylene diphosphonate apex views of the affected distal femoral growth plate were performed. The knee was flexed into its smallest angle. Using a pinhole collimator the gamma camera was angled to face the affected growth plate end on. The image was collected onto computer and analysed by: (I) regions of interest over segments of the growth plate to calculate the relative area of total growth plate affected: (II) generating histograms: (III) thresholding or performing isocontours to accentuate abnormal areas. The growth plate is normally uniformly increased when compared to the normal shaft of the bone. Fusion across the plate appears as an area of diminished uptake. The apex view gives a unique functional map of the growth plate such that abnormal areas are displayed, and the site, size and position of osseus fusion obtained. The technique has the potential for determining the metabolic activity of the growth plate before and after surgery. Serial studies will allow assessment of regneration of the plate and reformation of new osseus bridges

  18. Multicenter, Randomized, Controlled Study Comparing Tafluprost/Timolol Fixed Combination with Latanoprost/Timolol Fixed Combination in Primary Open-Angle Glaucoma and Ocular Hypertension.

    Science.gov (United States)

    Suzuki, Katsuyoshi; Otsuka, Naomi; Hizaki, Hiroko; Hashimoto, Masayo; Kuwayama, Yasuaki

    2018-06-05

    This was the first exploratory randomized controlled study to compare the efficacy and safety of a preserved tafluprost/timolol fixed combination (TAF/TIM) with a preserved latanoprost/timolol fixed combination (LAT/TIM). This prospective, randomized, open-label study was conducted in Japanese patients with primary open-angle glaucoma, including normal-tension glaucoma or ocular hypertension. Following a 4-week LAT/TIM run-in period, eligible patients entered a 12-week treatment period, during which they received either LAT/TIM or TAF/TIM. The efficacy endpoint was the change in intraocular pressure (IOP) from baseline to week 12 and the safety endpoints included the changes from baseline to week 12 in superficial punctate keratopathy (SPK) score, tear breakup time (TBUT), and hyperemia score, as well as adverse events (AEs). At week 6, ocular symptoms were evaluated using a questionnaire. In total, 131 patients provided informed consent. Of these, 115 completed the run-in period and were assigned to receive TAF/TIM (n = 60) or LAT/TIM (n = 55). At week 12, there were no significant differences between the TAF/TIM and LAT/TIM groups in the change from baseline in trough IOP and IOP at 4-6 h after instillation. There were no significant differences between the two groups in the change from baseline to week 12 in SPK score, TBUT, and hyperemia score. However, only in the TAF/TIM group, the total SPK score and the inferior cornea SPK score were significantly lower at week 12 compared with baseline. Eye irritation and eye pain were significantly decreased in the TAF/TIM group compared with the LAT/TIM group. Two treatment-related AEs were reported in the TAF/TIM group (3.3%) and none in the LAT/TIM group, while no serious AEs were reported in either group. TAF/TIM is as effective as LAT/TIM in terms of IOP-reducing effect, with fewer ocular symptoms. TAF/TIM was associated with a significant improvement in SPK scores. UMIN Clinical Trials Registry Identifier

  19. Aerodynamic drag reduction by vertical splitter plates

    Energy Technology Data Exchange (ETDEWEB)

    Gillieron, Patrick [Renault Group, Research Division, Fluid Mechanics and Aerodynamics, Guyancourt (France); Kourta, Azeddine [Polytech' Orleans, Institut PRISME, ESA, Orleans (France)

    2010-01-15

    The capacity of vertical splitter plates placed at the front or the rear of a simplified car geometry to reduce drag, with and without skew angle, is investigated for Reynolds numbers between 1.0 x 10{sup 6} and 1.6 x 10{sup 6}. The geometry used is a simplified geometry to represent estate-type vehicles, for the rear section, and MPV-type vehicle. Drag reductions of nearly 28% were obtained for a zero skew angle with splitter plates placed at the front of models of MPV or utility vehicles. The results demonstrate the advantage of adapting the position and orientation of the splitter plates in the presence of a lateral wind. All these results confirm the advantage of this type of solution, and suggest that this expertise should be used in the automotive field to reduce consumption and improve dynamic stability of road vehicles. (orig.)

  20. Optimization of geometrical characteristics of perforated plates

    International Nuclear Information System (INIS)

    Radisavljevic, Igor; Balos, Sebastian; Nikacevic, Milutin; Sidjanin, Leposava

    2013-01-01

    Highlights: ► Perforated plate are tested against 12.7 mm API projectile. ► Perforations similar to the projectile diameter offer more efficient core fracture. ► Larger perforations gave a more efficient core fragmentation. ► SEM microscopy analysis has shown a ductile fracture mode at impact point. - Abstract: In this paper, an attempt was made to design effective non-homogenous armor in form of perforated plate mounted at close distance from basic armor plate. Perforated plate with three perforation diameters: 9, 10 and 11 mm, two ligaments length: 3.5 and 4.5 mm ligaments, set at 0° and 28° angles, were combined to 13 mm basic plate and tested against 12.7 mm API ammunition. It has been shown that larger perforations gave a more efficient core fragmentation, while angled specimens were the only ones that offer full protection against five API shots when the perforated plate was placed at 100 mm from the basic plate. Perforations that are similar in size to the penetrating core diameter offer a more efficient core fracture, leading to a faster fragment separation. This may enable a smaller distance between the add-on perforated and basic plate to be used. Scanning electron microscopy analysis has shown a ductile fracture mode at impact point, with hardness values on plate basic level. On the other hand, a brittle fracture mode with a rise in local hardness measured near impact point is a result of intensive high speed plastic deformation produced by bending stresses. A drop in local hardness measured near impact point, may be the result of intensive cracking that occur due to repeated projectile impact

  1. Evaluation of the Effect of Fixation Angle between Polyaxial Pedicle Screw Head and Rod on the Failure of Screw-Rod Connection

    Directory of Open Access Journals (Sweden)

    Engin Çetin

    2015-01-01

    Full Text Available Introduction. Polyaxial screws had been only tested according to the ASTM standards (when they were perpendicularly positioned to the rod. In this study, effects of the pedicle screws angled fixation to the rod on the mechanical properties of fixation were investigated. Materials and Method. 30 vertically fixed screws and 30 screws fixed with angle were used in the study. Screws were used in three different diameters which were 6.5 mm, 7.0 mm, and 7.5 mm, in equal numbers. Axial pull-out and flexion moment tests were performed. Test results compared with each other using appropriate statistical methods. Results. In pull-out test, vertically fixed screws, in 6.5 mm and 7.0 mm diameter, had significantly higher maximum load values than angled fixed screws with the same diameters (P<0.01. Additionally, vertically fixed screws, in all diameters, had significantly greater stiffness according to corresponding size fixed with angle (P<0.005. Conclusion. Fixing the pedicle screw to the rod with angle significantly decreased the pull-out stiffness in all diameters. Similarly, pedicle screw instrumentation fixed with angle decreased the minimum sagittal angle between the rod and the screw in all diameters for flexion moment test but the differences were not significant.

  2. A folded plate clamped along one side only

    Science.gov (United States)

    Nazarov, Serguei A.; Slutskij, Andrey S.

    2017-12-01

    An asymptotic model of a folded thin elastic plate is posed on two plane domains and contains transmission conditions at the common line segment of their boundaries. These conditions become non-local and inhomogeneous if only one side of the plate is fixed. Solvability and smoothness results and error estimates for the model are derived. xml:lang="fr"

  3. Experimental And Theoretical Stress Analysis For Composite Plate Under Combined Load

    Directory of Open Access Journals (Sweden)

    Emad Qasim Hussein

    2017-12-01

    Full Text Available The combined effects of thermal and mechanical loadings on the distribution of stress-strain for E-glass fiber /polyester composite plates are investigated experimentally and numerically. The experimental work has been carried out by applying to a uniform temperature and tensile load on the composite plate inside the furnace and the deformation of plate measured by a dial gauge. Two parameter studies, the fiber volume fraction and fiber orientation on the stress-strain for plates subjected to identical mechanical and temperature gradient. The results presented showed that, the maximum absolute of total strain in longitudinal direction occurred at 50 N tension load and fiber angle 60º, while the minimum absolute values of it occurred at 15 N tension loads and fiber angle 0º. However the maximum absolute of total strain in transverse direction occurred at 15N tension load and fiber angle 0º, while the minimum absolute values of it are obtained at 50 N tension loads and fiber angle 60º. Also, the total strain in longitudinal and transverse direction decrease with increasing the fiber volume fraction. Comparison of the results in the experimental test with the numerical analysis of the total strain and evaluated the agreement between the two methods used, the maximum discrepancywas 20%.

  4. Improvement of Plating Characteristics Between Nickel and PEEK by Plasma Treatment and Chemical Etching

    International Nuclear Information System (INIS)

    Lee, Hye W.; Lee, Jong K.; Park, Ki Y.

    2009-01-01

    Surface of PEEK(poly-ether-ether-ketone) was modified by chemical etching, plasma treatment and mechanical grinding to improve the plating adhesion. The plating characteristics of these samples were studied by the contact angle, plating thickness, gloss and adhesion. Chemical etching and plasma treatment increased wettability, adhesion and gloss. The contact angle of as-received PEEK was 61 .deg. . The contact angles of chemical etched, plasma treated or both were improved to the range of 15∼33 .deg. . In the case of electroless plating, the thickest layer without blister was 1.6 μm. The adhesion strengths by chemical etching, plasma treatment or both chemical etching and plasma treatment were 75 kgf/cm 2 , 102 kgf/cm 2 , 113 kgf/cm 2 , respectively, comparing to the 24 kgf/cm 2 of as-received. In the case of mechanically ground PEEKs, the adhesion strengths were higher than those unground, with the sacrifice of surface gloss. The gloss of untreated PEEK were greater than mechanically ground PEEKs. Plating thickness increased linearly with the plating times

  5. [Extramedullary fixation combined with intramedullary fixation in the surgical reduction of sagittal mandibular condylar fractures].

    Science.gov (United States)

    Chuanjun, Chen; Xiaoyang, Chen; Jing, Chen

    2016-10-01

    This study aimed to evaluate the clinical effect of extramedullary fixation combined with intramedullary fixation during the surgical reduction of sagittal mandibular condylar fractures. Twenty-four sagittal fractures of the mandibular condyle in18 patients were fixed by two appliances: intramedullary with one long-screw osteosynthesis or Kirschner wire and extramedullary with one micro-plate. The radiologically-recorded post-operative stability-associated com-plications included the screw/micro-plate loosening, micro-plate twisting, micro-plate fractures, and fragment rotation. The occluding relations, the maximalinter-incisal distances upon mouth opening, and the mandibular deflection upon mouth opening were evaluated based on follow-up clinical examination. Postoperative panoramic X-ray and CT scans showed good repositioning of the fragment, with no redislocation or rotation, no screw/plate loosening, and no plate-twisting or fracture. Clinical examination showed that all patients regained normal mandibular movements, ideal occlusion, and normal maximal inter-incisal distances upon mouth opening. Extramedullary fixation combined with intramedullary fixation is highly recommended for sagittal condylar fractures because of the anti-rotation effect of the fragment and the reasonable place-ment of the fixation appliances.

  6. Effect of plasma actuator and splitter plate on drag coefficient of a circular cylinder

    Science.gov (United States)

    Akbıyık, Hürrem; Erkan Akansu, Yahya; Yavuz, Hakan; Ertuğrul Bay, Ahmet

    2016-03-01

    In this paper, an experimental study on flow control around a circular cylinder with splitter plate and plasma actuator is investigated. The study is performed in wind tunnel for Reynolds numbers at 4000 and 8000. The wake region of circular cylinder with a splitter plate is analyzed at different angles between 0 and 180 degrees. In this the study, not only plasma actuators are activated but also splitter plate is placed behind the cylinder. A couple electrodes are mounted on circular cylinder at ±90 degrees. Also, flow visualization is achieved by using smoke wire method. Drag coefficient of the circular cylinder with splitter plate and the plasma actuator are obtained for different angles and compared with the plain circular cylinder. While attack angle is 0 degree, drag coefficient is decreased about 20% by using the splitter plate behind the circular cylinder. However, when the plasma actuators are activated, the improvement of the drag reduction is measured to be 50%.

  7. Surgical treatment of mandibular condyle fractures using the retromandibular anterior transparotid approach and a triangular-positioned double miniplate osteosynthesis technique: A clinical and radiological evaluation of 124 fractures.

    Science.gov (United States)

    Dalla Torre, Daniel; Burtscher, Doris; Widmann, Gerlig; Pichler, Albina; Rasse, Michael; Puelacher, Wolfgang

    2015-07-01

    Different modalities have been described regarding the treatment of mandibular condyle fractures. The most advantageous and safest one is still a topic of discussion. The present analysis describes the combination of a retromandibular, transparotideal approach combined to a triangular-positioned double-miniplate osteosynthesis, with a special regard for the patients' long term outcomes. Clinical data of 102 patients with 124 condyle fractures treated with the mentioned surgical procedure were evaluated. Functional parameters such as the maximal interincisal distance, deviations/deflections, facial nerve function, occlusion as well as complications regarding the parotid gland, osteosynthesis, and esthetics were evaluated 1 week, 2 weeks, 3 months, and 6 months postoperatively. The mean maximal interincisal distance ranged from 38 mm after 1 week to 45 mm after 6 months. Deviations/deflections were seen in 22.5% of the cases 1 week postoperatively and decreased to 2% at 6 months postoperatively. A temporary facial palsy was diagnosed in 3.9% during the first follow-up, whereas no impairment was recorded after 3 or 6 months. At the same time, no patient had occlusional disturbances or complications regarding the parotid gland or the osteosynthesis 6 months postoperatively. Direct fracture visualization and a stable three-dimensional fracture stabilization are the main advantages of the presented combination of a surgical approach and osteosynthesis technique. Additionally, the absence of long-term complications confirms the safety of the procedure. Therefore, it may be considered as a successful treatment option for mandibular condyle fractures. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  8. Efficacy and tolerability of fixed-combination brinzolamide/timolol in Latin American patients with open-angle glaucoma or ocular hypertension previously on brimonidine/timolol fixed combination.

    Science.gov (United States)

    Alezzandrini, Arturo; Hubatsch, Douglas; Alfaro, Rene

    2014-09-01

    Fixed-combination glaucoma medications are commonly used to achieve target intraocular pressure (IOP) reduction in patients uncontrolled with monotherapy; however, ocular discomfort associated with eye drops can decrease adherence. This study assessed the efficacy and tolerability of twice-daily fixed-combination brinzolamide 1%/timolol 0.5% (BRINZ/TIM-FC) in Latin American patients transitioned from fixed-combination brimonidine 0.2%/timolol 0.5% (BRIM/TIM-FC) because of insufficient IOP control or treatment intolerance. This 8-week, open-label, prospective study was conducted at six sites in Argentina, Chile, and Mexico. Enrolled patients were aged ≥18 years with open-angle glaucoma (including primary, exfoliative, or pigment-dispersion glaucoma) or ocular hypertension with IOP of 19-35 mmHg in ≥1 eye at baseline (on BRIM/TIM-FC). Patients self-administered BRINZ/TIM-FC to both eyes at 8 a.m. and 8 p.m. daily for 8 weeks. The primary and secondary efficacy endpoints were mean IOP change from baseline at week 8 and percentage of patients achieving target IOP (≤18 mmHg) at week 8, respectively. Exploratory endpoints included patient and investigator preference for treatment at week 8. Adverse events (AEs) were assessed as the safety endpoint. Fifty patients (mean ± SD age, 66.7 ± 11.5 years) received BRINZ/TIM-FC, and 49 were included in the intent-to-treat population. Mean ± SD IOP was significantly reduced from baseline after 8 weeks of treatment with BRINZ/TIM-FC (-3.6 ± 3.0 mmHg; P Wilcoxon signed-rank test; 17.1% reduction). Overall, 55.3% of patients achieved IOP ≤18 mmHg at week 8. Significantly more patients (89.4%) and investigators (95.7%) preferred BRINZ/TIM-FC to BRIM/TIM-FC (both P test). Of the 13 AEs observed, 8 were related to BRINZ/TIM-FC; the most common treatment-related AEs were eye irritation (n = 4) and abnormal sensation in the eye (n = 2). BRINZ/TIM-FC provides an effective and well-tolerated treatment

  9. Comparación biomecánica entre los sistemas convencionales y uni-lock en osteosíntesis del ángulo mandibular: Estudio fotoelástico Biomechanical comparison of the conventional and uni-lock systems for mandibular osteosynthesis: A photoelastic study

    Directory of Open Access Journals (Sweden)

    José Luis Cebrián-Carretero

    2012-03-01

    distribution using different osteosynthesis methods in mandibular body fractures. Results: The results showed that the simulator and 3D photoelasticity were useful for studying interactions between bone and osteosynthesis materials. The "Lock" system displayed the most favourable stress distribution in the epoxy resin mandible. Conclusions: 3D photoelasticity in epoxy resin models is a useful method to evaluate stress distribution for biomechanical studies. In terms of mandibular osteosynthesis, "lock" plates show the most favourable stress distribution due to being less aggressive to the bone.

  10. Stress analysis of implant-bone fixation at different fracture angle

    Science.gov (United States)

    Izzawati, B.; Daud, R.; Afendi, M.; Majid, MS Abdul; Zain, N. A. M.; Bajuri, Y.

    2017-10-01

    Internal fixation is a mechanism purposed to maintain and protect the reduction of a fracture. Understanding of the fixation stability is necessary to determine parameters influence the mechanical stability and the risk of implant failure. A static structural analysis on a bone fracture fixation was developed to simulate and analyse the biomechanics of a diaphysis shaft fracture with a compression plate and conventional screws. This study aims to determine a critical area of the implant to be fractured based on different implant material and angle of fracture (i.e. 0°, 30° and 45°). Several factors were shown to influence stability to implant after surgical. The stainless steel, (S. S) and Titanium, (Ti) screws experienced the highest stress at 30° fracture angle. The fracture angle had a most significant effect on the conventional screw as compared to the compression plate. The stress was significantly higher in S.S material as compared to Ti material, with concentrated on the 4th screw for all range of fracture angle. It was also noted that the screws closest to the intense concentration stress areas on the compression plate experienced increasing amounts of stress. The highest was observed at the screw thread-head junction.

  11. Effect of manual tilt adjustments on incident irradiance on fixed and tracking solar panels

    International Nuclear Information System (INIS)

    Lubitz, William David

    2011-01-01

    Hourly typical meteorological year (TMY3) data was utilized with the Perez radiation model to simulate solar radiation on fixed, azimuth tracking and two axis tracking surfaces at 217 geographically diverse temperate latitude sites across the contiguous United States of America. The optimum tilt angle for maximizing annual irradiation on a fixed south-facing panel varied from being equal to the latitude at low-latitude, high clearness sites, to up to 14 o less than the latitude at a north-western coastal site with very low clearness index. Across the United States, the optimum tilt angle for an azimuth tracking panel was found to be on average 19 o closer to vertical than the optimum tilt angle for a fixed, south-facing panel at the same site. Azimuth tracking increased annual solar irradiation incident on a surface by an average of 29% relative to a fixed south-facing surface at optimum tilt angle. Two axis tracking resulted in an average irradiation increase of 34% relative to the fixed surface. Introduction of manual surface tilt changes during the year produced a greater impact for non-tracking surfaces than it did for azimuth tracking surfaces. Even monthly tilt changes only resulted in an average annual irradiation increase of 5% for fixed panels and 1% for azimuth tracked surfaces, relative to using a single optimized tilt angle in each case. In practice, the decision whether to manually tilt panels requires balancing the added cost in labor and the panel support versus the extra energy generation and the cost value of that energy. A spreadsheet file is available that gives individual results for each of the 217 simulated sites.

  12. Wettability measurements of irregular shapes with Wilhelmy plate method

    Science.gov (United States)

    Park, Jaehyung; Pasaogullari, Ugur; Bonville, Leonard

    2018-01-01

    One of the most accurate methods for measuring the dynamic contact angle of liquids on solid surfaces is the Wilhelmy plate method. This method generally requires the use of rectangular samples having a constant perimeter in the liquid during advancing and receding cycles. A new formulation based on the Wilhelmy force balance equation to determine the contact angle for plate samples with irregular shapes has been developed. This method employs a profile plot obtained from an optical image to determine the perimeter (i.e. wetted length) of the sample as a function of the immersion depth. The raw force data measured by the force tensiometer is manipulated using the profile plot and the Wilhelmy equation to determine the wetting force and consequently advancing and the receding contact angle. This method is verified with both triangular and irregular PTFE samples in water, and measured contact angles are in good agreement with results from conventional regular shaped samples with a constant perimeter.

  13. Parametric study on nonlinear vibration of composite truss core sandwich plate with internal resonance

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Jia Nen; Liu, Jun [Tianjin Key Laboratory of the Design and Intelligent Control of the Advanced Mechatronical System, Tianjin University of Technology, Tianjin (China); Zhang, Wei; Yao, Ming Hui [College of Mechanical Engineering, Beijing University of Technology, Beijing (China); Sun, Min [School of Science, Tianjin Chengjian University, Tianjin (China)

    2016-09-15

    Nonlinear vibrations of carbon fiber reinforced composite sandwich plate with pyramidal truss core are investigated. The governing equation of motion for the sandwich plate is derived by using a Zig-Zag theory under consideration of geometrically nonlinear. The natural frequencies of sandwich plates with different dimensions are calculated and compared with those obtained from the classic laminated plate theory and Reddy's third-order shear deformation plate theory. The frequency responses and waveforms of the sandwich plate when 1:3 internal resonance occurs are obtained, and the characteristics of the internal resonance are discussed. The influences of layer number of face sheet, strut radius, core height and inclination angle on the nonlinear responses of the sandwich plate are analyzed. The results demonstrate that the strut radius and inclination angle mainly affect the resonance frequency band of the sandwich plate, and the layer number and core height not only influence the resonance frequency band but also significantly affect the response amplitude.

  14. Stress analysis of plate-fin structures in recuperator

    International Nuclear Information System (INIS)

    Matsui, Shingo; Muto, Yasushi; Shiina, Yasuaki

    2001-01-01

    A high performance compact recuperator with 95% effectiveness is required to achieve a high thermal efficiency power generation of up to 50% in High Temperature Gas Cooled Reactor (HTGR) coupled with closed cycle helium gas turbine. Though a plate-fin type heat exchanger is proposed for this recuperator, much research and development works are needed to establish this high performance goal since there exists no state-of-the-art technology in such a high pressure and high temperature one. One of the important works is to establish the structural analysis and evaluation method in this plate-fin type heat exchanger. This paper describes the results of stress analysis of the plate-fin structure under the internal pressure as the first step of this work. First, the modeling of a unit plate-fin structure for the analysis was examined and a three layers model was confirmed to be most adequate. The stress distribution within the structure was clarified by using this model. Second, the three layers model was simplified to one layer model with sufficient accuracy. By using this model, both the effects of an inclined angle of fin and a thickness of separate on the strength were examined parametrically. Under the relevant design conditions, it was revealed that the optimum inclined angle of fin locates in the neighborhood of 76 degree rather than most difficult fabrication angle 90 degree and there is possibility to adopt thinner thickness than 0.5 mm in the current design. (author)

  15. The mechanical benefit of medial support screws in locking plating of proximal humerus fractures.

    Directory of Open Access Journals (Sweden)

    Wen Zhang

    Full Text Available BACKGROUND: The purpose of this study was to evaluate the biomechanical advantages of medial support screws (MSSs in the locking proximal humeral plate for treating proximal humerus fractures. METHODS: Thirty synthetic left humeri were randomly divided into 3 subgroups to establish two-part surgical neck fracture models of proximal humerus. All fractures were fixed with a locking proximal humerus plate. Group A was fixed with medial cortical support and no MSSs; Group B was fixed with 3 MSSs but without medial cortical support; Group C was fixed with neither medial cortical support nor MSSs. Axial compression, torsional stiffness, shear stiffness, and failure tests were performed. RESULTS: Constructs with medial support from cortical bone showed statistically higher axial and shear stiffness than other subgroups examined (P<0.0001. When the proximal humerus was not supported by medial cortical bone, locking plating with medial support screws exhibited higher axial and torsional stiffness than locking plating without medial support screws (P ≤ 0.0207. Specimens with medial cortical bone failed primarily by fracture of the humeral shaft or humeral head. Specimens without medial cortical bone support failed primarily by significant plate bending at the fracture site followed by humeral head collapse or humeral head fracture. CONCLUSIONS: Anatomic reduction with medial cortical support was the stiffest construct after a simulated two-part fracture. Significant biomechanical benefits of MSSs in locking plating of proximal humerus fractures were identified. The reconstruction of the medial column support for proximal humerus fractures helps to enhance mechanical stability of the humeral head and prevent implant failure.

  16. Chuck for machining armature casings and angles

    International Nuclear Information System (INIS)

    Tashlitskii, A.I.; Matskevich, A.I.

    1984-01-01

    When machining T-joints and angles, the test specimen must be fixed before being placed in the desired position. This is quite a complex operation and is achieved in a few stages. At the Scientific Production Combine ''Kislorodmash,'' a new chuck was designed which in one pressing of the jaws seats and fixes the specimen. In the clamped condition, the chuck helps rotate and fix the specimen in one of the four positions. Rotating and fixing are manual. The chuck developed ensured a distinct interdependence of the axes of the branches being machined as the specimen remains fixed throughout the period of machining, and provides reliable fixing of the specimen, and there are no clearances when the specimen is fixed with a special wedge. When using the chuck, the ancillary movements of the operator are reduced to a minimum thus increasing the labor productivity

  17. Effects of temperature and velocity of droplet ejection process of simulated nanojets onto a moving plate's surface

    International Nuclear Information System (INIS)

    Fang, T.-H.; Chang, W.-J.; Lin, S.-L.

    2006-01-01

    This paper uses molecular dynamics simulation based on the Lennard-Jones potential to study the effects that temperature and velocity have on, the nanojet droplet ejection process, when the droplet is ejected at an angle onto a moving plate's surface. According to the analysis, it was found that the width of the spreading droplet increased as the temperature and the time were increased. Also found was an energy wave phenomenon. The contact angle of the droplet deposited on the plate decreased as the temperature was increased. Furthermore, the layer phenomena became apparent when the atoms were deposited on a moving plate. Thinner film layers were obtained as the velocity of the moving plate was increased. The contact angle on the left side of the droplet was larger than that on the right side when the plate was moving from right to left

  18. Comparison of the efficacy and safety of fixed combination travoprost/timolol and dorzolamide/timolol in patients with primary open-angle glaucoma and ocular hypertension

    Directory of Open Access Journals (Sweden)

    Babić Nikola

    2013-01-01

    Full Text Available Introduction. Combining two medications in one bottle may improve compliance by reducing the time required to administer drops and the frequency of the total number of medication bottles. Objective. To compare the efficacy of reduced intraocular pressure (IOP and safety of fixed combination travoprost 0.004%/timolol 0.5% vs. fixed combination dorzolamide 2%/timolol 0.5% in patients with primary open-angle glaucoma or ocular hypertension. Methods. Prospective randomized clinical study included 60 patients divided into 2 groups. Follow-up was done at day 14 and 45 and month 3. IOP measurements were taken at each follow-up examination at 8 am, 10 am and 4 pm. Results. Both fixed combinations reduced IOP significantly compared to initial values at all follow-ups (p<0.001. Mean pooled IOP at all visits and time points was slightly lower in the travoprost/timolol group compared with the dorzolamide/timolol group (16.13 mmHg vs. 16.15 mmHg. Mean IOP reduction from baseline ranged from -7.46 mmHg to -9.92 mmHg in the travoprost/timolol group and from -6.93 mmHg to -8.93 mmHg for the dorzolamide/timolol group. Mean (±standard error of the mean reduction in diurnal IOP from baseline to 3rd month was 8.96±2.79 in the travoprost/timolol group versus 8.07±2.91 in patients receiving dorzolamide/timolol fixed combination (p=0.196. The most frequent treatment-related adverse events were conjunctival hyperemia in the travoprost/timolol group, and dry eye and foreign body sensation in the dorzolamide/timolol group. Conclusion. Travoprost/timolol fixed combination was slightly more effective than dorzolamide/timolol fixed combination in reducing mean diurnal IOP. Travoprost/timolol group resulted in an IOP reduction for up to 1.07 mmHg higher than dorzolamide/timolol group. Both fixed combinations were well tolerated and safe.

  19. Design and operation of AFC ramp plates for track clearance on longwall faces

    Energy Technology Data Exchange (ETDEWEB)

    Shaw, I R

    1975-10-01

    A study of the use of AFC ramp plates carried out in the University of Newcastle upon Tyne is reported. A 1/4-scale ramp plate test rig was designed and the effects of pushing force, ramp plate toe angle, track width and other factors were studied.

  20. Minimally invasive locked plating of distal tibia fractures is safe and effective.

    Science.gov (United States)

    Ronga, Mario; Longo, Umile Giuseppe; Maffulli, Nicola

    2010-04-01

    Distal tibial fractures are difficult to manage. Limited soft tissue and poor vascularity impose limitations for traditional plating techniques that require large exposures. The nature of the limitations for traditional plating techniques is intrinsic to the large exposure required to approach distal tibia, a bone characterized by limited soft tissue coverage and poor vascularity. The locking plate (LP) is a new device for treatment of fractures. We assessed the bone union rate, deformity, leg-length discrepancy, ankle range of motion, return to preinjury activities, infection, and complication rate in 21 selected patients who underwent minimally invasive osteosynthesis of closed distal tibia fractures with an LP. According to the AO classification, there were 12 Type A, 5 Type B, and 4 Type C fractures. The minimum followup was 2 years (average, 2.8 years; range, 2-4 years). Two patients were lost to followup. Union was achieved in all but one patient by the 24th postoperative week. Four patients had angular deformity less than 7 degrees . No patient had a leg-length discrepancy more than 1.1 cm. Five patients had ankle range of motion less than 20 degrees compared with the contralateral side. Sixteen patients had not returned to their preinjury sporting or leisure activities. Three patients developed a delayed infection. We judge the LP a reasonable device for treating distal tibia fractures. The level of physical activities appears permanently reduced in most patients. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  1. Rib Fractures: To Fix or Not to Fix? An Evidence-Based Algorithm

    Directory of Open Access Journals (Sweden)

    Michael Bemelman

    2017-08-01

    Full Text Available Rib fractures are a common injury resulting from blunt chest trauma. The most important complications associated with rib fractures include death, pneumonia, and the need for mechanical ventilation. The development of new osteosynthesis materials has stimulated increased interest in the surgical treatment of rib fractures. Surgical stabilisation, however, is not needed for every patient with rib fractures or for every patient with flail chest. This paper presents an easy-to-use evidence-based algorithm, developed by the authors, for the treatment of patients with flail chest and isolated rib fractures.

  2. "A" shape plate for open rigid internal fixation of mandible condyle neck fracture.

    Science.gov (United States)

    Kozakiewicz, Marcin; Swiniarski, Jacek

    2014-09-01

    Reduction of the fracture is crucial for proper outcome of the treatment. The stability of reduction is closed connected to the method of its fixation. The topic of condylar fracture osteosynthesis still remains highly controversial and challenging. That is why authors decided to propose novel design of the fixating plate and the example of its application. The aim of this study was to present A-shape plate dedicated to rigid fixation of mandible condyle neck fracture. A-shape condylar plate (ACP) design is prepared of 1.0 mm thick titanium alloy (grade 5) sheet: posterior and anterior bars are reinforced by widening to 2.5 mm and anatomically curved along the compression and traction lines in ramus and condylar neck. Superior three-hole-group has triangular organization and located on the level of condylar head. The inferior extensions of the bars are equipped in three holes located at each of lower tails. Connecting bar (2.0 mm wide) connects the first hole of each lower tails closing upper part of ACP in triangular shape. The connecting bar runs along compression line of condylar neck. Holes in ACP has 2.0 mm diameter for locking or normal screws. Height of ACP is 31 mm. The proposed new type of plate was compared by finite element analysis (FEA) to nowadays manufactured 9-hole trapezoid plate as the most similar device. ACP design was evaluated by finite element analysis (FEA) and later applied in patient affected with high condylar neck fracture complicated by fracture of coronoid process. FEA revealed high strength of ACP and more stabile fixation than trapezoid plate. The result was caused by multipoint fixation at three regions of the plate and reinforced bars supported by semi-horizontal connecting bar. Clinical application of ACP was as versatile as makes possible to simultaneous fixation of high condylar neck and coronoid process fracture. Application of proposed A-shape condylar plate would be possible in all levels of neck fractures and can be use

  3. Stresses in Circular Plates with Rigid Elements

    Science.gov (United States)

    Velikanov, N. L.; Koryagin, S. I.; Sharkov, O. V.

    2018-05-01

    Calculations of residual stress fields are carried out by numerical and static methods, using the flat cross-section hypothesis. The failure of metal when exposed to residual stresses is, in most cases, brittle. The presence in the engineering structures of rigid elements often leads to the crack initiation and structure failure. This is due to the fact that rigid elements under the influence of external stresses are stress concentrators. In addition, if these elements are fixed by welding, the residual welding stresses can lead to an increase in stress concentration and, ultimately, to failure. The development of design schemes for such structures is a very urgent task for complex technical systems. To determine the stresses in a circular plate with a welded circular rigid insert under the influence of an external load, one can use the solution of the plane stress problem for annular plates in polar coordinates. The polar coordinates of the points are the polar radius and the polar angle, and the stress state is determined by normal radial stresses, tangential and shearing stresses. The use of the above mentioned design schemes, formulas, will allow more accurate determination of residual stresses in annular welded structures. This will help to establish the most likely directions of failure and take measures at the stages of designing, manufacturing and repairing engineering structures to prevent these failures. However, it must be taken into account that the external load, the presence of insulation can lead to a change in the residual stress field.

  4. Vibro-acoustic analysis of composite plates

    International Nuclear Information System (INIS)

    Sarigül, A S; Karagözlü, E

    2014-01-01

    Vibro-acoustic analysis plays a vital role on the design of aircrafts, spacecrafts, land vehicles and ships produced from thin plates backed by closed cavities, with regard to human health and living comfort. For this type of structures, it is required a coupled solution that takes into account structural-acoustic interaction which is crucial for sensitive solutions. In this study, coupled vibro-acoustic analyses of plates produced from composite materials have been performed by using finite element analysis software. The study has been carried out for E-glass/Epoxy, Kevlar/Epoxy and Carbon/Epoxy plates with different ply angles and numbers of ply. The effects of composite material, ply orientation and number of layer on coupled vibro-acoustic characteristics of plates have been analysed for various combinations. The analysis results have been statistically examined and assessed

  5. Vibro-acoustic analysis of composite plates

    Science.gov (United States)

    Sarigül, A. S.; Karagözlü, E.

    2014-03-01

    Vibro-acoustic analysis plays a vital role on the design of aircrafts, spacecrafts, land vehicles and ships produced from thin plates backed by closed cavities, with regard to human health and living comfort. For this type of structures, it is required a coupled solution that takes into account structural-acoustic interaction which is crucial for sensitive solutions. In this study, coupled vibro-acoustic analyses of plates produced from composite materials have been performed by using finite element analysis software. The study has been carried out for E-glass/Epoxy, Kevlar/Epoxy and Carbon/Epoxy plates with different ply angles and numbers of ply. The effects of composite material, ply orientation and number of layer on coupled vibro-acoustic characteristics of plates have been analysed for various combinations. The analysis results have been statistically examined and assessed.

  6. Mass transfer effects on vertical oscillating plate with heat flux

    Directory of Open Access Journals (Sweden)

    Muthucumaraswamy R.

    2007-01-01

    Full Text Available Theoretical solution of unsteady viscous incompressible flow past an infinite vertical oscillating plate with uniform heat flux and mass diffusion is presented here, taking into account of the homogeneous chemical reaction of first-order. The temperature from the plate to the fluid at an uniform rate and the mass is diffused uniformly. The dimensionless governing equations has been obtained by the Laplace transform method, when the plate is oscillating harmonically in its own plane. The effects of velocity and concentration are studied for different parameters like phase angle chemical reaction parameter, thermal Grashof number, mass Grashof number Schmidt number and time are studied. The so­lutions are valid only for small values of time t. It is observed that the velocity increases with decreasing phase angle ωt or chemical reaction parameter.

  7. Research on Radial Vibration of a Circular Plate

    Directory of Open Access Journals (Sweden)

    Wei Liu

    2016-01-01

    Full Text Available Radial vibration of the circular plate is presented using wave propagation approach and classical method containing Bessel solution and Hankel solution for calculating the natural frequency theoretically. In cylindrical coordinate system, in order to obtain natural frequency, propagation and reflection matrices are deduced at the boundaries of free-free, fixed-fixed, and fixed-free using wave propagation approach. Furthermore, radial phononic crystal is constructed by connecting two materials periodically for the analysis of band phenomenon. Also, Finite Element Simulation (FEM is adopted to verify the theoretical results. Finally, the radial and piezoelectric effects on the band are also discussed.

  8. Subduction Drive of Plate Tectonics

    Science.gov (United States)

    Hamilton, W. B.

    2003-12-01

    shrinking oceans, forcing rapid Pacific spreading. Slabs suck forward overriding arcs and continental lithosphere, plus most subjacent mantle above the transition zone. Changes in sizes of oceans result primarily from transfer of oceanic lithosphere, so backarcs and expanding oceans spread only slowly. Lithosphere parked in, or displaced from, the transition zone, or mixed into mid-upper mantle, is ultimately recycled, and regional variations in age of that submerged lithosphere may account for some regional contrasts in MORB. Plate motions make no kinematic sense in either the "hotspot" reference frame (HS; the notion of fixed plumes is easily disproved) or the no-net-rotation frame (NNR) In both, for example, many hinges roll forward, impossible with gravity drive. Subduction-drive predictions are fulfilled, and paleomagnetic data are satisfied (as they are not in HS and NNR), in the alternative framework of propulsionless Antarctica fixed relative to sluggish lower mantle. Passive ridges migrate away from Antarctica on all sides, and migration of these and other ridges permits tapping fresh asthenosphere. (HS and NNR tend to fix ridges). Ridge migration and spreading rates accord with subduction drive. All trenches roll back when allowance is made for back-arc spreading and intracontinental deformation. Africa rotates slowly toward subduction systems in the NE, instead of moving rapidly E as in HS and NNR. Stable NW Eurasia is nearly stationary, instead of also moving rapidly, and S and E Eurasian deformation relates to subduction and rollback. The Americas move Pacificward at almost the full spreading rates of passive ridges behind them. Lithosphere has a slow net westward drift. Reference: W.B. Hamilton, An alternative Earth, GSA Today, in press.

  9. Development of the neurocranium after transsutural fixing by new, resorbable poly-L-lactide miniplates. A comparison to fixing with the common titanium miniplates.

    Science.gov (United States)

    Antikainen, T; Pernu, H; Törmälä, P; Kallioinen, M; Waris, T; Serlo, W

    1994-01-01

    The right coronal sutures of twelve (12) newborn rabbits were fixed with commercially available, self-reinforced poly-L-lactide miniplates, with eight (8) rabbits sham treated with titanium miniplate fixation as reference experiments, in order to demonstrate the possible effects on skull growth. After six (6) months follow-up, both types of plate were detected to have caused a similar asymmetry in the neurocranium. Therefore, in our opinion, fixing across growing sutures, even with the new biodegradable devices, should be avoided.

  10. Two-Photon Luminescence and Second Harmonic Generation from Gold Micro-Plates

    Directory of Open Access Journals (Sweden)

    Xu Wang

    2014-09-01

    Full Text Available Micron-sized gold plates were prepared by reducing chloroauric acid with lemongrass extract. Their two-photon luminescence (TPL and second harmonic generation (SHG were investigated. The results show that the TPL and SHG intensity of gold plates is dependent on the wavelength and polarization of excitation laser. The TPL intensity of gold plates decreases with the increase of the excitation wavelength except for a small peak around 820–840 nm, while SHG intensity increases with the excitation wavelength redshift. In addition, it is found that the TPL intensity of the gold plate’s edge is related with the angle between the edge orientation and the polarization direction of the excitation light. The TPL intensity increases with the angle increase from 0° to 90°.

  11. Theoretical study of chemical reaction effects on vertical oscillating plate with variable temperature

    Directory of Open Access Journals (Sweden)

    Muthucumaraswamy R.

    2006-01-01

    Full Text Available An exact solution to the flow of a viscous incompressible unsteady flow past an infinite vertical oscillating plate with variable temperature and mass diffusion is presented here, taking into account of the homogeneous chemical reaction of first-order. Both the plate temperature and the concentration level near the plate are raised linearly with respect to time. The dimensionless governing equations has been obtained by the Laplace transform method, when the plate is oscillating harmonically in its own plane. The effects of velocity and concentration are studied for different parameters like phase angle, chemical reaction parameter, thermal Grashof number, mass Grashof number, Schmidt number and time are studied. The solutions are valid only for small values of time t. It is observed that the velocity increases with decreasing phase angle ωt or chemical reaction parameter. .

  12. Analysis of viscoplastic plates with material degradation using influence functions

    International Nuclear Information System (INIS)

    Fotiu, P.; Irschik, H.

    1987-01-01

    Influence functions are well-known from the computational analysis of linear elastic plates. For inelastic plates, unfortunately, this convenient Green's function method does not apply in its classical sense, because superposition of imposed loadings is not possible. However, following a complete elastic-inelastic analogy for small deflections of beams and plates, the inelastic part of strain may be treated as an additional source of self-stress in the linear elastic structure with fixed (initial) stiffness. Hence, the inelastic plate is analogous to the linear elastic one, but subjected to the imposed loadings as well as to fictitious additional sources of self-stress, likewise to a given thermal loading. (orig./GL)

  13. The new INRIM rotating encoder angle comparator (REAC)

    International Nuclear Information System (INIS)

    Pisani, Marco; Astrua, Milena

    2017-01-01

    A novel angle comparator has been built and tested at INRIM. The device is based on a double air bearing structure embedding a continuously rotating encoder, which is read by two heads: one fixed to the base of the comparator and a second fixed to the upper moving part of the comparator. The phase measurement between the two heads’ signals is proportional to the relative angle suspended between them (and, therefore, the angle between the base and the upper, movable part of the comparator). The advantage of this solution is to reduce the encoder graduation errors and to cancel the cyclic errors due to the interpolation of the encoder lines. By using only two pairs of reading heads, we have achieved an intrinsic accuracy of  ±0.04″ (rectangular distribution) that can be reduced through self-calibration. The residual cyclic errors have shown to be less than 0.01″ peak-to-peak. The random fluctuations are less than 0.01″ rms on a 100 s time interval. A further advantage of the rotating encoder is the intrinsic knowledge of the absolute position without the need of a zeroing procedure. Construction details of the rotating encoder angle comparator (REAC), characterization tests, and examples of practical use are given. (paper)

  14. Quasi-Linear Polarized Modes in Y-Rotated Piezoelectric GaPO4 Plates

    Directory of Open Access Journals (Sweden)

    Cinzia Caliendo

    2014-07-01

    Full Text Available The propagation of both surface and flexural acoustic plate modes along y-rotated x-propagation GaPO4 piezoelectric substrates was studied for several y-cut angles: the phase velocity and coupling coefficient dispersion curves were theoretically calculated for two different electroacoustic coupling configurations. The investigation of the acoustic field profile across the plate thickness revealed the presence of thin plate modes having polarization predominantly oriented along the propagation direction, and hence suitable for operation in liquid environment. These modes include the linearly polarized Anisimkin Jr. and the quasi longitudinal plate modes, AMs and QLs, showing a phase velocity close to that of the longitudinal bulk acoustic wave propagating in the same direction. The temperature coefficient of delay (TCD of these longitudinal modes was investigated in the −20 to 420 °C temperature range, in order to identify thermally stable or low TCD cuts. The power flow angle, i.e., the angle between the phase and group velocity vectors, was also estimated to evaluate the substrate anisotropy effect on the acoustic wave propagation. The GaPO4 intrinsic properties, such as its resistance to high temperature and its chemical inertness, make it especially attractive for the development of acoustic waves-based sensors for applications in harsh liquid environment.

  15. Structure of colloidal sphere-plate mixtures

    International Nuclear Information System (INIS)

    Doshi, N; Cinacchi, G; Van Duijneveldt, J S; Cosgrove, T; Prescott, S W; Grillo, I; Phipps, J; Gittins, D I

    2011-01-01

    In addition to containing spherical pigment particles, coatings usually contain plate-like clay particles. It is thought that these improve the opacity of the paint film by providing an efficient spacing of the pigment particles. This observation is counterintuitive, as suspensions of particles of different shapes and sizes tend to phase separate on increase of concentration. In order to clarify this matter a model colloidal system is studied here, with a sphere-plate diameter ratio similar to that found in paints. For dilute suspensions, small angle neutron scattering revealed that the addition of plates leads to enhanced density fluctuations of the spheres, in agreement with new theoretical predictions. On increasing the total colloid concentration the plates and spheres phase separate due to the disparity in their shape. This is in agreement with previous theoretical and experimental work on colloidal sphere-plate mixtures, where one particle acts as a depleting agent. The fact that no large scale phase separation is observed in coatings is ascribed to dynamic arrest in intimately mixed, or possibly micro-phase separated structures, at elevated concentration.

  16. Structure of colloidal sphere-plate mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Doshi, N; Cinacchi, G; Van Duijneveldt, J S; Cosgrove, T; Prescott, S W [School of Chemistry, University of Bristol, Bristol BS8 1TS (United Kingdom); Grillo, I [Institut Laue-Langevin, 6 rue Jules Horowitz BP 156, 38042 Grenoble Cedex 9 (France); Phipps, J [Imerys Minerals Ltd, Par Moor Centre, Par Moor Road, Par, Cornwall PL24 2SQ (United Kingdom); Gittins, D I, E-mail: Giorgio.Cinacchi@bristol.ac.uk, E-mail: J.S.van-Duijneveldt@bristol.ac.uk [Imerys Performance and Filtration Minerals Ltd, 130 Castilian Drive, Goleta, CA 93117 (United States)

    2011-05-18

    In addition to containing spherical pigment particles, coatings usually contain plate-like clay particles. It is thought that these improve the opacity of the paint film by providing an efficient spacing of the pigment particles. This observation is counterintuitive, as suspensions of particles of different shapes and sizes tend to phase separate on increase of concentration. In order to clarify this matter a model colloidal system is studied here, with a sphere-plate diameter ratio similar to that found in paints. For dilute suspensions, small angle neutron scattering revealed that the addition of plates leads to enhanced density fluctuations of the spheres, in agreement with new theoretical predictions. On increasing the total colloid concentration the plates and spheres phase separate due to the disparity in their shape. This is in agreement with previous theoretical and experimental work on colloidal sphere-plate mixtures, where one particle acts as a depleting agent. The fact that no large scale phase separation is observed in coatings is ascribed to dynamic arrest in intimately mixed, or possibly micro-phase separated structures, at elevated concentration.

  17. Ricochet of a tungsten heavy alloy long-rod projectile from deformable steel plates

    International Nuclear Information System (INIS)

    Lee, Woong; Lee, Heon-Joo; Shin, Hyunho

    2002-01-01

    Ricochet of a tungsten heavy alloy long-rod projectile from oblique steel plates with a finite thickness was investigated numerically using a full three-dimensional explicit finite element method. Three distinctive regimes resulting from oblique impact depending on the obliquity, namely simple ricochet, critical ricochet and target perforation, were investigated in detail. Critical ricochet angles were calculated for various impact velocities and strengths of the target plates. It was predicted that critical ricochet angle increases with decreasing impact velocities and that higher ricochet angles were expected if higher strength target materials are employed. Numerical predictions were compared with existing two-dimensional analytical models. Experiments were also carried out and the results supported the predictions of the numerical analysis

  18. Condensation heat transfer in plate heat exchangers

    International Nuclear Information System (INIS)

    Panchal, C.B.

    1985-01-01

    An Alfa-Laval plate heat exchanger, previously tested as an evaporator, was retested as a condenser. Two series of tests with different chevron-angle plates were carried out using ammonia as a working fluid. The overall heat-transfer coefficient and pressure drop were measured, and the effects of operating parameters were determined. The experimental data were compared with theoretical predictions. In the analysis, a gravity-controlled condensation process was modeled theoretically, and the overall performance was calculated. The analysis shows that the overall heat-transfer coefficient can be predicted with an average uncertainty of about 10%. It is, however, important to consider the interfacial shear stress, because the effective friction factor is high for flow in plate heat exchangers

  19. Ponderomotive phase plate for transmission electron microscopes

    Science.gov (United States)

    Reed, Bryan W [Livermore, CA

    2012-07-10

    A ponderomotive phase plate system and method for controllably producing highly tunable phase contrast transfer functions in a transmission electron microscope (TEM) for high resolution and biological phase contrast imaging. The system and method includes a laser source and a beam transport system to produce a focused laser crossover as a phase plate, so that a ponderomotive potential of the focused laser crossover produces a scattering-angle-dependent phase shift in the electrons of the post-sample electron beam corresponding to a desired phase contrast transfer function.

  20. Surface mobility and structural transitions of poly(n-alkyl methacrylates) probed by dynamic contact angle measurements

    NARCIS (Netherlands)

    van Damme, H.S.; Hogt, A.H.; Feijen, Jan

    1986-01-01

    Dynamic contact angles and contact-angle hysteresis of a series of poly(n-alkyl methacrylates) (PAMA) were investigated using the Wilhelmy plate technique. The mobility of polymer surface chains, segments, and side groups affected the measured contact angles and their hysteresis. A model is

  1. Screening and Crystallization Plates for Manual and High-throughput Protein Crystal Growth

    Science.gov (United States)

    Thorne, Robert E. (Inventor); Berejnov, Viatcheslav (Inventor); Kalinin, Yevgeniy (Inventor)

    2010-01-01

    In one embodiment, a crystallization and screening plate comprises a plurality of cells open at a top and a bottom, a frame that defines the cells in the plate, and at least two films. The first film seals a top of the plate and the second film seals a bottom of the plate. At least one of the films is patterned to strongly pin the contact lines of drops dispensed onto it, fixing their position and shape. The present invention also includes methods and other devices for manual and high-throughput protein crystal growth.

  2. An imaging method of wavefront coding system based on phase plate rotation

    Science.gov (United States)

    Yi, Rigui; Chen, Xi; Dong, Liquan; Liu, Ming; Zhao, Yuejin; Liu, Xiaohua

    2018-01-01

    Wave-front coding has a great prospect in extending the depth of the optical imaging system and reducing optical aberrations, but the image quality and noise performance are inevitably reduced. According to the theoretical analysis of the wave-front coding system and the phase function expression of the cubic phase plate, this paper analyzed and utilized the feature that the phase function expression would be invariant in the new coordinate system when the phase plate rotates at different angles around the z-axis, and we proposed a method based on the rotation of the phase plate and image fusion. First, let the phase plate rotated at a certain angle around the z-axis, the shape and distribution of the PSF obtained on the image surface remain unchanged, the rotation angle and direction are consistent with the rotation angle of the phase plate. Then, the middle blurred image is filtered by the point spread function of the rotation adjustment. Finally, the reconstruction images were fused by the method of the Laplacian pyramid image fusion and the Fourier transform spectrum fusion method, and the results were evaluated subjectively and objectively. In this paper, we used Matlab to simulate the images. By using the Laplacian pyramid image fusion method, the signal-to-noise ratio of the image is increased by 19% 27%, the clarity is increased by 11% 15% , and the average gradient is increased by 4% 9% . By using the Fourier transform spectrum fusion method, the signal-to-noise ratio of the image is increased by 14% 23%, the clarity is increased by 6% 11% , and the average gradient is improved by 2% 6%. The experimental results show that the image processing by the above method can improve the quality of the restored image, improving the image clarity, and can effectively preserve the image information.

  3. Application of biodegradable plates for treating pediatric mandibular fractures.

    Science.gov (United States)

    An, Jingang; Jia, Pengcheng; Zhang, Yi; Gong, Xi; Han, Xiaodong; He, Yang

    2015-05-01

    We assessed the clinical results of a biodegradable plate system for the internal fixation of mandibular fractures in children, and observed the imaging features of fracture healing and bone changes around the biodegradable plates and screws during follow-up. We enrolled 39 patients (22 male, 17 female, average age 4 years 10 months) with different mandibular fractures. We used 2.0-mm resorbable plates to repair the fractures. Postoperative follow-up ranged from 6 months to 5 years; average follow-up was 1 year 2 months. The outcome measures identified and assessed included facial symmetry, mouth opening, occlusal relationship, infection, nonunion, malunion, and plate dehiscence. We fixed 42 fractures with 43 resorbable plates; the fracture site of one patient (aged 11 years 3 months) was fixed with two plates. Two patients developed small fistulas at the intraoral incision 2 months after surgery; the fistulas healed after 1 month without special treatment. In the other patients, the incision healed well, there was facial symmetry, mouth opening was >35 mm, and occlusion was good. Follow-up computed tomography examination data were available for 20 cases, and revealed different degrees of radiolucency indicating that osteolysis had occurred. Radiolucency was observed around the resorbable plates 1 month after the surgery. The extent and depth of the radiolucent region were obvious within 1 year of surgery. In the second year, there were obvious repairs, with the bony defect areas becoming shallower. After 2 years, the bony defect areas had almost disappeared. Biodegradable fixation devices are safe and efficient for treating pediatric mandibular fractures. Osteolysis commonly follows biodegradable fixation of pediatric mandibular fractures, and has no adverse effect on fracture healing. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  4. Hydrodynamics of a three-dimensional self-propelled flexible plate

    Science.gov (United States)

    Ryu, Jaeha; Sung, Hyung Jin

    2017-11-01

    A three-dimensional self-propelled flexible plate in a quiescent flow was simulated using the immersed boundary method. The clamped leading edge of the flexible plate was forced into a vertical oscillation, while free to move horizontally. To reveal the hydrodynamics of the plate, the averaged cruising speed (UC) , the input power (P) , and the swimming efficiency (η) were analyzed as a function of the bending rigidity (γ) and the flapping frequency (f) . The velocity field around the plate and the exerted force on the plate were demonstrated to find out the dynamic interaction between the plate and the surrounding fluid. The kinematics of the plate, the maximum angle of attack (ϕmax) , and the mean effective length (Leff) were examined accounting for the hydrodynamics of the self-propelled flexible plate. The vortical structures around the plate were visualized, and the influence of the tip vortex on the swimming efficiency was explored qualitatively and quantitatively. This work was supported by the Creative Research Initiatives (No. 2017-013369) program of the National Research Foundation of Korea (MSIP).

  5. Comparison of skeletal stability after sagittal split ramus osteotomy among mono-cortical plate fixation, bi-cortical plate fixation, and hybrid fixation using absorbable plates and screws.

    Science.gov (United States)

    Ueki, Koichiro; Moroi, Akinori; Yoshizawa, Kunio; Hotta, Asami; Tsutsui, Takamitsu; Fukaya, Kenichi; Hiraide, Ryota; Takayama, Akihiro; Tsunoda, Tatsuta; Saito, Yuki

    2017-02-01

    The purpose of this study was to examine skeletal stability and plate breakage after sagittal split ramus osteotomy (SSRO) with the mono-cortical plate fixation, bi-cortical plate fixation, and hybrid fixation techniques using absorbable plates and screws. A total of 76 Japanese patients diagnosed with mandibular prognathism with and without maxillary deformity were divided into 3 groups randomly. A total of 28 patients underwent SSRO with mono-cortical plate fixation, 23 underwent SSRO with bi-cortical plate fixation, and 25 underwent SSRO with hybrid fixation. Skeletal stability and horizontal condylar angle were analyzed by axial, frontal, and lateral cephalograms from before the operation to 1 year postoperatively. Breakage of the plate and screws was observed by 3-dimensional computed tomography (3DCT) immediately after surgery and after 1 year. Although there was a significant difference between the mono-cortical plate fixation group and hybrid fixation group regarding right MeAg in T1 (P = 0.0488) and occlusal plane in T1 (P = 0.0346), there were no significant differences between the groups for the other measurements in each time interval. In 2 cases, namely, 6 sides in the mono-cortical plate fixation group, breakage of the absorbable plate was found by 3DCT. However, there was no breakage in the bi-cortical plate fixation group and hybrid fixation group. This study results suggested that there were no significant differences in the postoperative skeletal stability among the 3 groups, and bi-cortical fixation as well as hybrid fixation was a reliable and useful method to prevent plate breakage even if an absorbable material was used. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  6. Improved fixed point iterative method for blade element momentum computations

    DEFF Research Database (Denmark)

    Sun, Zhenye; Shen, Wen Zhong; Chen, Jin

    2017-01-01

    The blade element momentum (BEM) theory is widely used in aerodynamic performance calculations and optimization applications for wind turbines. The fixed point iterative method is the most commonly utilized technique to solve the BEM equations. However, this method sometimes does not converge...... are addressed through both theoretical analysis and numerical tests. A term from the BEM equations equals to zero at a critical inflow angle is the source of the convergence problems. When the initial inflow angle is set larger than the critical inflow angle and the relaxation methodology is adopted...

  7. Control of the flow in the annular region of a shrouded cylinder with splitter plate

    Directory of Open Access Journals (Sweden)

    Ozkan Gokturk Memduh

    2017-01-01

    Full Text Available In the present study, the flow control with a splitter plate was studied considering the annular region of a shrouded cylinder. The effect of splitter plate angle, α which was defined according to the cylinder centreline is investigated experimentally in deep water using Particle image Velocimetry (PIV technique and flow visualization by dye injection method. The range of splitter plate angle was selected within 60°≤ α ≤180° with an increment of 30°. The porosity of the shroud which is a perforated cylinder was selected as β=0.7 in order to have larger fluid entrainment through the cylinder. The results were compared with the no-plate case and showed that the splitter plate located in the annular region of shrouded cylinders is effective on reducing the turbulence levels just behind the cylinder base, as well as the near wake of the perforated shroud.

  8. Control of the flow in the annular region of a shrouded cylinder with splitter plate

    Science.gov (United States)

    Ozkan, Gokturk Memduh; Durhasan, Tahir; Pinar, Engin; Yenicun, Arda; Akilli, Huseyin; Sahin, Besir

    In the present study, the flow control with a splitter plate was studied considering the annular region of a shrouded cylinder. The effect of splitter plate angle, α which was defined according to the cylinder centreline is investigated experimentally in deep water using Particle image Velocimetry (PIV) technique and flow visualization by dye injection method. The range of splitter plate angle was selected within 60°≤ α ≤180° with an increment of 30°. The porosity of the shroud which is a perforated cylinder was selected as β=0.7 in order to have larger fluid entrainment through the cylinder. The results were compared with the no-plate case and showed that the splitter plate located in the annular region of shrouded cylinders is effective on reducing the turbulence levels just behind the cylinder base, as well as the near wake of the perforated shroud.

  9. Stress Intensity Factors of Slanted Cracks in Bi-Material Plates

    Science.gov (United States)

    Ismail, Al Emran; Azhar Kamarudin, Kamarul; Nor, Nik Hisyamudin Muhd

    2017-10-01

    In this study, the stress intensity factors (SIF) of slanted cracks in bi-material plates subjected to mode I loading is numerically solved. Based on the literature survey, tremendous amount of research works are available studying the normal cracks in both similar and dissimilar plates. However, lack of SIF behavior for slanted cracks especially when it is embedded in bi-material plates. The slanted cracks are then modelled numerically using ANSYS finite element program. Two plates of different in mechanical properties are firmly bonded obliquely and then slanted edge cracks are introduced at the lower inclined edge. Isoparametric singular element is used to model the crack tip and the SIF is determined which is based on the domain integral method. Three mechanical mismatched and four slanted angles are used to model the cracks. According to the present results, the effects of mechanical mismatch on the SIF for normal cracks are not significant. However, it is played an important role when slanted angles are introduced. It is suggested that higher SIF can be obtained when the cracks are inclined comparing with the normal cracks. Consequently, accelerating the crack growth at the interface between two distinct materials.

  10. Bone tissue density modification in treatment of shin pseudoarthrosis by transosseous compressive osteosynthesis

    Directory of Open Access Journals (Sweden)

    Tishkov N.V.

    2011-12-01

    Full Text Available Objective is to detect bone mineral density along the shin according to «Esperanto» levels by Hounsfield's scale. Materials and methods. The analysis of density modification in 25 patients with pseudoarthrosis of tibia with predominant localization in a lower one-third of bone has been carried out. Results. By means of computed tomography it has been revealed that the bone tissue density of the tibia in the process of false joint union when using the compressive variant of combined transosseous osteosynthesis has changed according to the regularity reproducing phase character of the accumulation of mineral substances in the bone. Conclution. The growth of mineral density of the bone tissue during treatment spreads in the directions from proximal and distal metaepiphyses to the zone of pseudoarthrosis knitting

  11. Hot-rolled Process of Multilayered Composite Metal Plate

    Directory of Open Access Journals (Sweden)

    YU Wei

    2017-02-01

    Full Text Available For multi-layer plate, it is a difficult problem to increase product yield rate and improve bonding interface quality. A high yield hot-rolled method of multilayered plate was proposed. The raw strips and plate were fixed by argon arc welding. The combined billet was put into a metal box and vacuum pumped, and then heated and rolled by multi passes at the temperature of 1000-1200℃. The 67 layered plate with the thickness of 2.5mm was successfully produced. The interfacial microstructures and diffusion behavior were investigated and analyzed by optical microscopy and scan electronic microscopy. The tensile and shear strength were tested,and the shear fractures were analyzed. The results show that the multilayered plate yield rate is more than 90% by two steps billet combination method and rolling process optimization. The good bonding interface quality is obtained, the shear strength of multilayered plate reaches 241 MPa. Nickel interlayer between 9Cr18 and 1Cr17 can not only prevent the diffusion of carbon, but also improve the microstructure characteristics.

  12. Efficacy and Tolerability of Fixed-Combination Brinzolamide/Timolol in Latin American Patients with Open-Angle Glaucoma or Ocular Hypertension Previously on Brimonidine/Timolol Fixed Combination

    OpenAIRE

    Alezzandrini, Arturo; Hubatsch, Douglas; Alfaro, Rene

    2014-01-01

    Introduction Fixed-combination glaucoma medications are commonly used to achieve target intraocular pressure (IOP) reduction in patients uncontrolled with monotherapy; however, ocular discomfort associated with eye drops can decrease adherence. This study assessed the efficacy and tolerability of twice-daily fixed-combination brinzolamide 1%/timolol 0.5% (BRINZ/TIM-FC) in Latin American patients transitioned from fixed-combination brimonidine 0.2%/timolol 0.5% (BRIM/TIM-FC) because of insuffi...

  13. Study on the fixed point in crustal deformation before strong earthquake

    Science.gov (United States)

    Niu, A.; Li, Y.; Yan, W. Mr

    2017-12-01

    Usually, scholars believe that the fault pre-sliding or expansion phenomenon will be observed near epicenter area before strong earthquake, but more and more observations show that the crust deformation nearby epicenter area is smallest(Zhou, 1997; Niu,2009,2012;Bilham, 2005; Amoruso et al., 2010). The theory of Fixed point t is a branch of mathematics that arises from the theory of topological transformation and has important applications in obvious model analysis. An important precursory was observed by two tilt-meter sets, installed at Wenchuan Observatory in the epicenter area, that the tilt changes were the smallest compared with the other 8 stations around them in one year before the Wenchuan earthquake. To subscribe the phenomenon, we proposed the minimum annual variation range that used as a topological transformation. The window length is 1 year, and the sliding length is 1 day. The convergence of points with minimum annual change in the 3 years before the Wenchuan earthquake is studied. And the results show that the points with minimum deformation amplitude basically converge to the epicenter region before the earthquake. The possible mechanism of fixed point of crustal deformation was explored. Concerning the fixed point of crust deformation, the liquidity of lithospheric medium and the isostasy theory are accepted by many scholars (Bott &Dean, 1973; Merer et al.1988; Molnar et al., 1975,1978; Tapponnier et al., 1976; Wang et al., 2001). To explain the fixed point of crust deformation before earthquakes, we study the plate bending model (Bai, et al., 2003). According to plate bending model and real deformation data, we have found that the earthquake rupture occurred around the extreme point of plate bending, where the velocities of displacement, tilt, strain, gravity and so on are close to zero, and the fixed points are located around the epicenter.The phenomenon of fixed point of crust deformation is different from former understandings about the

  14. Lactated Ringer's solution or 0.9% sodium chloride as fluid therapy in pigeons (Columba livia submitted to humerus osteosynthesis

    Directory of Open Access Journals (Sweden)

    Adriano B. Carregaro

    2015-01-01

    Full Text Available The study aimed to compare the effects of intraosseous infusion of lactated Ringer's and 0.9% sodium chloride solutions on the electrolytes and acid-base balance in pigeons submitted to humerus osteosynthesis. Eighteen pigeons were undergoing to isoflurane anesthesia by an avalvular circuit system. They were randomly assigned into two groups (n=9 receiving lactated Ringer's solution (LR or 0.9% sodium chloride (SC, in a continuous infusion rate of 20mL/kg/h, by using an intraosseous catheter into the tibiotarsus during 60-minute anesthetic procedure. Heart rate (HR, and respiratory rate (RR were measured every 10 min. Venous blood samples were collected at 0, 30 and 60 minutes to analyze blood pH, PvCO2, HCO3 -, Na+ and K+. Blood gases and electrolytes showed respiratory acidosis in both groups during induction, under physical restraint. This acidosis was evidenced by a decrease of pH since 0 min, associated with a compensatory response, observed by increasing of HCO3 - concentration, at 30 and 60 min. It was not observed any changes on Na+ and K+ serum concentrations. According to the results, there is no reason for choosing one of the two solutions, and it could be concluded that both fluid therapy solutions do not promote any impact on acid-base balance and electrolyte concentrations in pigeons submitted to humerus osteosynthesis.

  15. Characteristics of heat transfer and fluid flow in a channel with single-row plates array oblique to flow direction for photovoltaic/thermal system

    International Nuclear Information System (INIS)

    Ali, Ahmed Hamza H.; Ahmed, Mahmoud; Youssef, M.S.

    2010-01-01

    This study has been carried out to investigate the characteristics of convective heat transfer and fluid flow for a single row of oblique plates array to the flow direction inside a channel. The flow inside the channel is laminar and the plates array have spanwise distance between the plates and heated by radiation. This configuration has been designed to be used for Photovoltaic/Thermal system (PV/T) applications. The theoretical results are validated with measured values, and a good agreement prevailed. The results show that an increase in the plate oblique angle (γ) in the range from 0 to 15 degrees, leads to an increase in the Nusselt number (Nu) up to a maximum value and then decreases. The oblique angle at the maximum value of Nu depends on the flow Reynolds Number (Re), and (l w /l pl ), where (l w /l pl ) is defined as the ratio of the plates' spacing at zero oblique angle to the plate length. Furthermore, increasing (l w /l pl ) results in a significant increase in the heat transfer coefficient depending on the values of Re, and plate oblique angle (γ). In addition, increasing (γ) from 0 to 15 degrees results in a decrease in the friction factor up to a certain value, after which the friction value approaches a constant value depending on Re value and (l w /l pl ). It was found that for any value of the plate oblique angle (γ), the friction factor decreases with the increase of the values of (l w /l pl ) and Re, respectively.

  16. Surface roughness effects on plasma near a divertor plate and local impact angle

    Directory of Open Access Journals (Sweden)

    Wanpeng Hu

    2017-08-01

    Full Text Available The impact of rough surface topography on the electric potential and electric field is generally neglected due to the small scale of surface roughness compared to the width of the plasma sheath. However, the distributions of the electric potential and field on rough surfaces are expected to influence the characteristics of edge plasma and the local impact angle. The distributions of plasma sheath and local impact angle on rough surfaces are investigated by a two dimension-in-space and three dimension-in-velocity (2d3v Particle-In-Cell (PIC code. The influences of the plasma temperature andsurface morphology on the plasma sheath, local impact angle and resulting physical sputtering yield on rough surfaces are investigated.

  17. Study regarding the influence of the crimping angle on the performances of the heat exchangers

    Directory of Open Access Journals (Sweden)

    Opruta D.

    2013-04-01

    Full Text Available The aim of this study is to determine the geometry of a plate for heat exchanger with high heat flow and low values for pressure losses. For this, in Solid Work software, were designed three plate geometries with different crimping angles for the flow channels. Was analyzed the influence of the crimping angle β on the fluid distribution and heat transfer. Also, were compared the data resulted from Computational Fluid Dynamics numeric simulation with the experimental ones for the plate heat exchangers with gaskets. The analysis of the vortices and temperature field distribution was achieved with the aid of simulation software Fluent. In order to validate the numerical simulation's results experimental research were carried out on a heat exchangers stand

  18. Distal femoral osteotomy in genovalgum: internal fixation with blade plate versus casting.

    Science.gov (United States)

    Makhmalbaf, Hadi; Moradi, Ali; Ganji, Saeid

    2014-10-01

    To compare the results of two different ways of distal femoral osteotomy stabilization in patients suffering from genuvalgum: internal fixation with plate, and casting. In a non-randomized prospective study, after distal femoral osteotomy with the zigzag method, patients were divided into two groups: long leg casting, and internal fixation with blade plate. For all patients, questionnaires were filled to obtain data. Information such as range of motion, tibiofemoral anatomical angle and complications were recorded. 38 knees with valgus deformity underwent distal femoral supracondylar osteotomy. (8 with plaster cast and 30 with internal fixation using a blade plate). Preoperative range of motion was 129±6° and six months later it was 120±14°. The preoperative tibiofemoral angle was 32±6°; postoperative tibiofemoral angles were 3±3°, 6±2°, and 7±3° just after operation, six months, and two years later, respectively. Although this angle was greater among the group stabilized with a cast, this difference was not statistically significant. In postoperative complications, over-correction was found in five, recorvatom deformity in one, knee stiffness in three and superficial wound infection was recorded in three knees. There is no prominent difference in final range of motion and alignment whether fixation is done with casting or internal fixation. However, the complication rate seems higher in the casting method.

  19. A FUNCTIONAL EVALUATION STUDY OF DISTAL FEMORAL FRACTURES FIXED WITH DISTAL FEMORAL LOCKING PLATE

    Directory of Open Access Journals (Sweden)

    Manikumar C. J

    2017-04-01

    Full Text Available BACKGROUND Fractures of the distal femur present considerable challenges in management. Older patients especially women sustain fractures due to osteoporosis. Supracondylar fractures of femur have a bimodal distribution. They account for 6% of all femur fractures and 31% if hip fractures were excluded. Nearly, 50% of distal femur intra-articular fractures are open fractures. Before 1970, most supracondylar fractures were treated nonoperatively; however, difficulties were often encountered including persistent angulatory deformity, knee joint incongruity, loss of knee motion and delayed mobilisation. The trend of open reduction and internal fixation has become evident in recent years with good results being obtained with AO blade plate, dynamic condylar screw, intramedullary supracondylar nail and locking compression plate. Elderly patients and osteoporosis pose difficulty in treating intra-articular fractures of the lower end of femur. Loss of stable fixation is of great concern in these cases. Hence, locking compression plate use has an advantage in these patients. MATERIALS AND METHODS In this study, 20 patients with closed fracture of distal femur were studied. All the cases were treated at the Department of Orthopaedics, Rangaraya Medical College/Government General Hospital, Kakinada, Andhra Pradesh, between November 2013 and November 2015. The method used for fracture fixation was open reduction and internal fixation with distal femoral locking plate. The duration of follow up ranged from 3 months to 24 months. All the fractures in this series were posttraumatic. The patients were functionally evaluated with Neer’s scoring system. 1 RESULTS Twenty distal femoral fractures were treated with distal femoral locking plates. 15 patients were males and 5 patients were females. The median age was 47 years ranging from 28-70 years. 16 of the fractures were caused by road traffic accidents and 2 were due to fall, 2 were due to assault. 12 patients

  20. Angle closure glaucoma in congenital ectropion uvea.

    Science.gov (United States)

    Wang, Grace M; Thuente, Daniel; Bohnsack, Brenda L

    2018-06-01

    Congenital ectropion uvea is a rare anomaly, which is associated with open, but dysplastic iridocorneal angles that cause childhood glaucoma. Herein, we present 3 cases of angle-closure glaucoma in children with congenital ectropion uvea. Three children were initially diagnosed with unilateral glaucoma secondary to congenital ectropion uvea at 7, 8 and 13 years of age. The three cases showed 360° of ectropion uvea and iris stromal atrophy in the affected eye. In one case, we have photographic documentation of progression to complete angle closure, which necessitated placement of a glaucoma drainage device 3 years after combined trabeculotomy and trabeculectomy. The 2 other cases, which presented as complete angle closure, also underwent glaucoma drainage device implantation. All three cases had early glaucoma drainage device encapsulation (within 4 months) and required additional surgery (cycloablation or trabeculectomy). Congenital ectropion uvea can be associated with angle-closure glaucoma, and placement of glaucoma drainage devices in all 3 of our cases showed early failure due to plate encapsulation. Glaucoma in congenital ectropion uvea requires attention to angle configuration and often requires multiple surgeries to obtain intraocular pressure control.

  1. Study Effect of Central Rectangular Perforation on the Natural Convection Heat Transfer in an Inclined Heated Flat Plate

    Directory of Open Access Journals (Sweden)

    Kadhum Audaa Jehhef

    2015-09-01

    Full Text Available Anumerical solutions is presented to investigate the effect of inclination angle (θ , perforation ratio (m and wall temperature of the plate (Tw on the heat transfer in natural convection from isothermal square flat plate up surface heated (with and without concentrated hole. The flat plate with dimensions of (128 mm length × (64 mm width has been used five with square models of the flat plate that gave a rectangular perforation of (m=0.03, 0.06, 0.13, 0.25, 0.5. The values of angle of inclination were (0o, 15o 30o 45o 60o from horizontal position and the values of wall temperature (50oC, 60 oC, 70 oC, 90 oC, 100oC. To investigate the temperature, boundary layer thickness and heat flux distributions; the numerical computation is carried out using a very efficient integral method to solve the governing equation. The results show increase in the temperature gradient with increase in the angle of inclination and the high gradient and high heat transfer coefficients located in the external edges of the plate, for both cases: with and without holed plate. There are two separation regions of heat transfer in the external edge and the internal edges. The boundary layer thickness is small in the external edge and high in the center of the plate and it decreases as the inclination angle of plate increases. Theoretical results are compared with previous result and it is found that the Nusslet numbers in the present study are higher by (22 % than that in the previous studies. And the results show good agreement in range of Raleigh number from 105 to 106.

  2. Heat transfer analysis to investigate the core catcher plate assembly in SFR

    International Nuclear Information System (INIS)

    Patil, Swapnil; Sharma, Anil Kumar; Velusamy, K.; Nashine, B.K.; Selvaraj, P.

    2015-01-01

    Severe accident scenario in Sodium Cooled Fast Reactor (SFR) is the major concern for public acceptance. After severe accident, the molten core continuously generates substantial decay heat. However, an in-vessel core catcher plate is provided to remove the decay heat passively. The numerical investigation of pool hydraulics phenomena in sodium pool of typical Indian SFR has been carried out. The debris may form a heap with different angle over the core catcher plate due to molten fuel density and interaction force. Therefore, the debris bed with different heap angle has been analyzed for steady and transient state conditions. The governing equation of fluid flow and heat transfer are solved by finite volume method based solver with the k-ε turbulent model. The time period Δ for which temperature is exceeding above safety limit with different debris heap angle have been established. (author)

  3. Small Angle Neutron Scattering experiments on ``side-on fixed"" liquid crystal polyacrylates

    Science.gov (United States)

    Leroux, N.; Keller, P.; Achard, M. F.; Noirez, L.; Hardouin, F.

    1993-08-01

    Small Angle Neutron Scattering experiments were carried out on liquid crystalline “side-on fixed” polyacrylates : we observe that the polymer backbone adopts a prolate conformation in the nematic phase. Such anisotropy of the global backbone is larger for smaller spacer length. In every case we measure at low temperatures a large chain extension as previously described in polysiloxanes. Par diffusion des neutrons aux petits angles nous observons que la chaîne de polyacrylates “en haltère” adopte une conformation type prolate en phase nématique. Son anisotropie est d'autant plus grande que l'espaceur est plus court. Dans tous les cas, nous retrouvons à basse température la forte extension de la chaîne polymère qui fut d'abord révélée dans les polysiloxanes.

  4. Centering and fixing device of a control rod guide flange on a nuclear reactor core plate

    International Nuclear Information System (INIS)

    Chevereau, G.

    1990-01-01

    The device comprises at least two pins diametrally opposite entering into holes in the core plate and self locking pads sliding into bores in the flange. These pads have a command mechanism blocking the lateral displacement of the pads on the plate [fr

  5. Exact solution of thermal radiation on vertical oscillating plate with variable temperature and mass flux

    Directory of Open Access Journals (Sweden)

    Muthucumaraswamy R.

    2010-01-01

    Full Text Available Thermal radiation effects on unsteady flow past an infinite vertical oscillating plate in the presence of variable temperature and uniform mass flux is considered. The fluid considered here is a gray, absorbing-emitting radiation but a non-scattering medium. The plate temperature is raised linearly with time and the mass is diffused from the plate to the fluid at an uniform rate. The dimensionless governing equations are solved using the Laplace transform technique. The velocity, concentration and temperature are studied for different physical parameters like the phase angle, radiation parameter, Schmidt number, thermal Grashof number, mass Grashof number and time. It is observed that the velocity increases with decreasing phase angle ωt.

  6. The interaction of thermal radiation on vertical oscillating plate with variable temperature and mass diffusion

    Directory of Open Access Journals (Sweden)

    Muthucumaraswamy R.

    2006-01-01

    Full Text Available Thermal radiation effects on unsteady free convective flow of a viscous incompressible flow past an infinite vertical oscillating plate with variable temperature and mass diffusion has been studied. The fluid considered here is a gray, absorbing-emitting radiation but a non-scattering medium. The plate temperature is raised linearly with respect to time and the concentration level near the plate is also raised linearly with respect to time. An exact solution to the dimensionless governing equations has been obtained by the Laplace transform method, when the plate is oscillating harmonically in its own plane. The effects of velocity, temperature and concentration are studied for different parameters like phase angle, radiation parameter, Schmidt number, thermal Grashof number, mass Grashof number and time are studied. It is observed that the velocity increases with decreasing phase angle ωt. .

  7. Angle closure glaucoma in congenital ectropion uvea

    Directory of Open Access Journals (Sweden)

    Grace M. Wang

    2018-06-01

    Full Text Available Purpose: Congenital ectropion uvea is a rare anomaly, which is associated with open, but dysplastic iridocorneal angles that cause childhood glaucoma. Herein, we present 3 cases of angle-closure glaucoma in children with congenital ectropion uvea. Observations: Three children were initially diagnosed with unilateral glaucoma secondary to congenital ectropion uvea at 7, 8 and 13 years of age. The three cases showed 360° of ectropion uvea and iris stromal atrophy in the affected eye. In one case, we have photographic documentation of progression to complete angle closure, which necessitated placement of a glaucoma drainage device 3 years after combined trabeculotomy and trabeculectomy. The 2 other cases, which presented as complete angle closure, also underwent glaucoma drainage device implantation. All three cases had early glaucoma drainage device encapsulation (within 4 months and required additional surgery (cycloablation or trabeculectomy. Conclusions and importance: Congenital ectropion uvea can be associated with angle-closure glaucoma, and placement of glaucoma drainage devices in all 3 of our cases showed early failure due to plate encapsulation. Glaucoma in congenital ectropion uvea requires attention to angle configuration and often requires multiple surgeries to obtain intraocular pressure control. Keywords: Congenital ectropion uvea, Juvenile glaucoma, Angle-closure glaucoma, Glaucoma drainage device

  8. Influence of different methods of internal bone fixation on characteristics of bone callus in experimental animals

    Directory of Open Access Journals (Sweden)

    Gajdobranski Đorđe

    2014-01-01

    Full Text Available Introduction. Correct choice of osteosynthesis method is a very important factor in providing the optimal conditions for appropriate healing of the fracture. There are still disagreements about the method of stabilization of some long bone fractures. Critically observed, no method of fracture fixation is ideal. Each osteosynthesis method has both advantages and weaknesses. Objective. The objective of this study was to compare the results of the experimental application of three different internal fixation methods: plate fixation, intramedullary nail fixation and self-dynamisable internal fixator (SIF. Methods. A series of 30 animals were used (Lepus cuniculus as experimental animals, divided into three groups of ten animals each. Femoral diaphysis of each animal was osteotomized and fixed with one of three implants. Ten weeks later all animals were sacrificed and each specimen underwent histological and biomechanical testing. Results. Histology showed that the healing process with SIF was more complete and bone callus was more mature in comparison to other two methods. During biomechanical investigation (computerized bending stress test, it was documented with high statistical significance that using SIF led to stronger healing ten weeks after the operation. Conclusion. According to the results obtained in this study, it can be concluded that SIF is a suitable method for fracture treatment.

  9. Optical performance of vertical axis three azimuth angles tracked solar panels

    International Nuclear Information System (INIS)

    Ma, Yi; Li, Guihua; Tang, Runsheng

    2011-01-01

    In this work, a new sun-tracking concept was proposed, and the optical performance of solar panels with such sun-tracking system was theoretically investigated based on the developed mathematical method and monthly horizontal radiation. The mechanism of the proposed sun-tracking technique is that the azimuth angle of solar panels is daily adjusted three times at three fixed positions: eastward, southward and westward in the morning, noon, and afternoon, respectively, by rotating solar panels about the vertical axis (3A sun-tracking, in short). The analysis indicated that the tilt-angle of solar panels, β 3A , azimuth angle of solar panels in the morning and afternoon from due south, φ a , and solar hour angle when the azimuth angle adjustment was made in the morning and afternoon, ω a , were three key parameters affecting the optical performance of such tracked solar panels. Calculation results showed that, for 3A tracked solar panels with a yearly fixed tilt-angle, the maximum annual collectible radiation was above 92% of that on a solar panel with full 2-axis sun-tracking; whereas for those with the tilt-angle being seasonally adjusted, it was above 95%. Results also showed that yearly or seasonally optimal values of β 3A , φ a and ω a for maximizing annual solar gain were related to site latitudes, and empirical correlations for a quick estimation of optimal values of these parameters were proposed based on climatic data of 32 sites in China.

  10. [Comparison of screw' inserting angle through the 11th and 12th rib anterior approaches for L1 burst fracture].

    Science.gov (United States)

    Ma, Li-Tai; Liu, Hao; Li, Tao; Song, Yue-Ming; Pei, Fu-Xing; Liu, Li-Min; Gong, Quan; Zeng, Jian-Cheng; Feng, Gan-Jun; Zhou, Zhong-Jie

    2012-12-01

    To compare screw's inserting angle through the 11th and 12th rib in treating L1 burst fracture, explore effects on inserting screw and postoperative angle. From October 2007 to October 2010, 108 patients with L1 brust fracture treated through anterior approach were analyzed,including 68 males and 40 females, aged from 21 to 64 years (mean 38.22 years). All patients were divided into the 11th (A, 51 cases) and 12th (B, 57 cases) approach. The data of operation time,blood loss, duration of incision pain, JOA score, Oswestry score, VAS score, quality of life (SF-36), recovery of nervous function, coronal Cobb angle, included angle between screw and plate were observed. All patients were followed up for 9 to 37 months, mean 23 months. The operation time, blood loss, duration of incision pain, in group A were lower than group B (P0.05). There were no differences in Cobb angle before operation, but had significance after operation (P=0.000). There were statistically significance between two group in angle between screw and plate (P=0.000, P=0.003). The 11th rib approach for the treatment of L1 burst fracture has less effects on screw, less trauma and less angle between screw and plate.

  11. Vibration Analysis of Annular Sector Plates under Different Boundary Conditions

    Directory of Open Access Journals (Sweden)

    Dongyan Shi

    2014-01-01

    Full Text Available An analytical framework is developed for the vibration analysis of annular sector plates with general elastic restraints along each edge of plates. Regardless of boundary conditions, the displacement solution is invariably expressed as a new form of trigonometric expansion with accelerated convergence. The expansion coefficients are treated as the generalized coordinates and determined using the Rayleigh-Ritz technique. This work allows a capability of modeling annular sector plates under a variety of boundary conditions and changing the boundary conditions as easily as modifying the material properties or dimensions of the plates. Of equal importance, the proposed approach is universally applicable to annular sector plates of any inclusion angles up to 2π. The reliability and accuracy of the current method are adequately validated through numerical examples.

  12. Numerical Investigation of Jet Impingement Heat Transfer on a Flat plate

    Directory of Open Access Journals (Sweden)

    Asem Nabadavis

    2016-12-01

    Full Text Available The numerical investigation emphasizes on studying the heat transfer characteristics when a high velocity air jet impinges upon a flat plate having constant heat flux. Numerical analysis has been conducted by solving conservation equations of momentum, mass and energy with two equations based k- ε turbulence model to determine the wall temperature and Nu of the plate considering the flow to be incompressible. It was found from the investigation that the heat transfer rate increases with the increase of Reynolds number of the jet (Rej. It was also found that there is an optimum value for jet distance to nozzle diameter ratio (H/d for maximum heat transfer when all the other parameters were kept fixed. Similar results as above were found when two jets of air were used instead of one jet keeping the mass flow rate constant. For a two jets case it was also found that heat transfer rate over the surface increases when the jets are inclined outward compared to vertical and inward jets and also there exists an optimum angle of jet for maximum heat transfer. Further investigation was carried out for different jetto-jet separation distance for a twin jet impingement model where it was noted that heat transfer is more distributed in case of larger values of L and the rate of heat transfer increases as the separation between the jet increases till a certain point after which the rate of heat transfer decreases.

  13. Numerical simulation of droplet evaporation between two circular plates

    International Nuclear Information System (INIS)

    Bam, Hang Jin; Son, Gi Hun

    2015-01-01

    Numerical simulation is performed for droplet evaporation between two circular plates. The flow and thermal characteristics of the droplet evaporation are numerically investigated by solving the conservation equations of mass, momentum, energy and mass fraction in the liquid and gas phases. The liquid-gas interface is tracked by a sharp-interface level-set method which is modified to include the effects of evaporation at the liquid-gas interface and contact angle hysteresis at the liquid-gas-solid contact line. An analytical model to predict the droplet evaporation is also developed by simplifying the mass and vapor fraction equations in the gas phase. The numerical results demonstrate that the 1-D analytical prediction is not applicable to the high rate evaporation process. The effects of plate gap and receding contact angle on the droplet evaporation are also quantified.

  14. Primary stability of different plate positions and the role of bone substitute in open wedge high tibial osteotomy.

    Science.gov (United States)

    Takeuchi, Ryohei; Woon-Hwa, Jung; Ishikawa, Hiroyuki; Yamaguchi, Yuichiro; Osawa, Katsunari; Akamatsu, Yasushi; Kuroda, Koichi

    2017-12-01

    The purpose of this study was to compare the mechanical fixation strengths of anteromedial and medial plate positions in osteotomy, and clarify the effects of bone substitute placement into the osteotomy site. Twenty-eight sawbone tibia models were used. Four different models were prepared: Group A, the osteotomy site was open and the plate position was anteromedial; Group B, bone substitutes were inserted into the osteotomy site and the plate position was anteromedial; Group C, the osteotomy site was open and the plate position was medial; and Group D, bone substitutes were inserted into the osteotomy site and the plate position was medial. The loading condition ranged from 0 to 800N and one hertz cycles were applied. Changes of the tibial posterior slope angle (TPS), stress on the plate and lateral hinge were measured. The changes in the TPS and the stress on the plate were significantly larger in Group A than in Group C. These were significantly larger in Group A than in Group B, and in Group C than in Group D. There was no significant difference between Group B and Group D, and no significant difference between knee flexion angles of 0° and 10°. Stress on the lateral hinge was significantly smaller when bone substitute was used. A medial plate position was biomechanically superior to an anteromedial position if bone substitute was not used. Bone substitute distributed the stress concentration around the osteotomy gap and prevented an increase in TPS angle regardless of the plate position. Copyright © 2017. Published by Elsevier B.V.

  15. The Influence of Flexibility Coefficient on the Size of Internal Forces and Deformations in Circular Plates on Elastic Medium

    Directory of Open Access Journals (Sweden)

    Şandru Mirela

    2016-09-01

    Full Text Available This paper presents an analytical study which deals with the behavior of the circular plates in bending theory, considering the soil-structure interaction under Winkler's hypothesis. It was intended to illustrate the variation of internal forces and deformations according to the flexibility coefficient of plates considering three models: a fixed solid circular plate subjected to a uniformly distributed load, a fixed solid circular plate acted by a displacement applied on the exterior contour and a solid plate subjected to a temperature gradient. For this study the computation relations were written as a product between a dimensional and a non-dimensional factor, the last one indicating the variation of internal forces and deformations. For each type of action there are presented results obtained using the finite element method to illustrate the differences between this method and the analytical computation.

  16. Characteristics of heat transfer and fluid flow in a channel with single-row plates array oblique to flow direction for photovoltaic/thermal system

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Ahmed Hamza H. [Department of Energy Resources and Environmental Engineering, Egypt-Japan University of Science and Technology (E-JUST), P.O. Box 179, New Borg El-Arab City, Alexandria 21934 (Egypt); Ahmed, Mahmoud; Youssef, M.S. [Department of Mechanical Engineering, Faculty of Engineering, Assiut University, Assiut 71516 (Egypt)

    2010-09-15

    This study has been carried out to investigate the characteristics of convective heat transfer and fluid flow for a single row of oblique plates array to the flow direction inside a channel. The flow inside the channel is laminar and the plates array have spanwise distance between the plates and heated by radiation. This configuration has been designed to be used for Photovoltaic/Thermal system (PV/T) applications. The theoretical results are validated with measured values, and a good agreement prevailed. The results show that an increase in the plate oblique angle ({gamma}) in the range from 0 to 15 degrees, leads to an increase in the Nusselt number (Nu) up to a maximum value and then decreases. The oblique angle at the maximum value of Nu depends on the flow Reynolds Number (Re), and (l{sub w}/l{sub pl}), where (l{sub w}/l{sub pl}) is defined as the ratio of the plates' spacing at zero oblique angle to the plate length. Furthermore, increasing (l{sub w}/l{sub pl}) results in a significant increase in the heat transfer coefficient depending on the values of Re, and plate oblique angle ({gamma}). In addition, increasing ({gamma}) from 0 to 15 degrees results in a decrease in the friction factor up to a certain value, after which the friction value approaches a constant value depending on Re value and (l{sub w}/l{sub pl}). It was found that for any value of the plate oblique angle ({gamma}), the friction factor decreases with the increase of the values of (l{sub w}/l{sub pl}) and Re, respectively. (author)

  17. Various methods of determining the natural frequencies and damping of composite cantilever plates. 3. The Ritz method

    Science.gov (United States)

    Ekel'chik, V. S.; Ryabov, V. M.

    1997-03-01

    The Ritz method was used to determine the frequencies and forms of free vibrations of rectangular cantilever plates made of anisotropic laminated composites. Orthogonal Jacobi and Legendre polynomials were used as coordinate functions. The results of the calculations are in good agreement with the published experimental and calculated data of other authors for plates made of boron and carbon fiber reinforced plastics with different angles of reinforcement of unidirectional layers and different sequence of placing the layers, and also of isotropic plates. The dissipative characteristics in vibrations were determined on the basis of the concept of complex moduli. The solution of the frequency equation with complex coefficients yields a complex frequency; the loss factors are determined from the ratio of the imaginary component of the complex frequency to the real component. For plates of unidirectionally reinforced carbon fiber plastic with different relative length a detailed analysis of the influence of the angle of reinforcement on the interaction and frequency transformation and on the loss factor was carried out. The article shows that the loss factor of a plate depends substantially on the type of vibration mode: bending or torsional. It also examines the asymptotics of the loss factors of plates when their length is increased, and it notes that the binomial model of deformation leads to a noticeable error in the calculation of the loss factor of long plates when the angle of reinforcement lies in the range 20°<φ<70°.

  18. Oscillations of oblate drop between heterogeneous plates under uniform electric field

    Science.gov (United States)

    Kashina, M. A.; Alabuzhev, A. A.

    2018-01-01

    The forced oscillations of the incompressible fluid drop under the action of the uniform electric field are considered. In equilibrium, the drop has the form of a circular cylinder bounded axially by the parallel solid planes; the contact angle is right. An incompressible fluid of different density surrounds the drop. The external electric field acts as an external force that causes motion of the contact line. In order to describe this contact line motion, the modified Hocking boundary condition is applied: the velocity of the contact line is proportional to the deviation of the contact angle and the speed of the fast relaxation processes, whose frequency is proportional to twice the frequency of the electric field. The case of heterogeneous plates is investigated. We assume that the Hocking parameter depends on the polar angle in this case. The function describing the change in the coefficient of the interaction between the plate and the fluid (the contact line) is expanded in a series of the Laplace operator eigenfunctions.

  19. Effect of the substrate orientation on the formation of He-plates in Si

    International Nuclear Information System (INIS)

    Vallet, M.; Barbot, J. F.; Declémy, A.; Beaufort, M. F.; Reboh, S.

    2013-01-01

    The effect of the crystalline orientation on the implantation-induced strain/stress and on the formation of He-plates was studied by combining high-resolution X-ray scattering and transmission electron microscopy. The highest strains are obtained in (001)-oriented implanted substrates regardless of the fluence and of the channeling effects. The anisotropic properties of the silicon that generate an anisotropic elastic response of the substrate were taken into account to explain these different values of strain. Upon specific thermal annealing, it is shown that the formation of He-plates occurs only in the (001) habit planes regardless of the orientation of the substrates, non-tilted and tilted (001)-, (110)-, and (111)-substrates. Moreover, the distribution of He-plates in the (001) variants was found to be strongly dependent on the angle of the habit plane with the surface and on the intensity of the implantation-induced strain/stress. The implantation-induced stress thus favors the formation of He-plates in specific planes (of low angle with the surface) forming different defect configurations. The nucleation and growth of He-plates are thus discussed with regard to the implantation-induced stress

  20. Thermal Behaviour of Beams with Slant End-Plate Connection Subjected to Nonsymmetric Gravity Load

    Directory of Open Access Journals (Sweden)

    Farshad Zahmatkesh

    2014-01-01

    Full Text Available Research on the steel structures with confining of axial expansion in fixed beams has been quite intensive in the past decade. It is well established that the thermal behaviour has a key influence on steel structural behaviours. This paper describes mechanical behaviour of beams with bolted slant end-plate connection with nonsymmetric gravity load, subjected to temperature increase. Furthermore, the performance of slant connections of beams in steel moment frame structures in the elastic field is investigated. The proposed model proved that this flexible connection system could successfully decrease the extra thermal induced axial force by both of the friction force dissipation among two faces of slant connection and a small upward movement on the slant plane. The applicability of primary assumption is illustrated. The results from the proposed model are examined within various slant angles, thermal and friction factors. It can be concluded that higher thermal conditions are tolerable when slanting connection is used.

  1. Comparison of accuracy of lag screw placement in cephalocondylic nails and sliding hip screw plate fixation for extracapsular fractures of the neck of femur

    OpenAIRE

    Shyam Kumar, A. J.; Parmar, V.; Bankart, J.; Williams, S. C.; Harper, W. M.

    2006-01-01

    This study compared the accuracy of lag screw placement between extracapsular femoral fractures fixed with sliding hip screw plate systems and those fixed with cephalocondylic nails. It involved 75 retrospective radiographs of fractures fixed with either a cephalocondylic nail (32) or a sliding hip screw plate system (43). Postoperative anteroposterior and lateral radiographs of the hip were scanned using a digital X-ray scanner and measured using computer software. Measurements were conducte...

  2. Untitled

    African Journals Online (AJOL)

    Muiruri

    of thirty two operated cases developed significant shoulder joint stiffness. Shoulder arthroplasty was unavailable. Conclusion: Plate osteosynthesis is an effective method of treatment of .... fall from the standing position or even direct impact.

  3. Optimum Tilt Angle at Tropical Region

    Directory of Open Access Journals (Sweden)

    S Soulayman

    2015-02-01

    Full Text Available : One of the important parameters that affect the performance of a solar collector is its tilt angle with the horizon. This is because of the variation of tilt angle changes the amount of solar radiation reaching the collector surface. Meanwhile, is the rule of thumb, which says that solar collector Equator facing position is the best, is valid for tropical region? Thus, it is required to determine the optimum tilt as for Equator facing and for Pole oriented collectors. In addition, the question that may arise: how many times is reasonable for adjusting collector tilt angle for a definite value of surface azimuth angle? A mathematical model was used for estimating the solar radiation on a tilted surface, and to determine the optimum tilt angle and orientation (surface azimuth angle for the solar collector at any latitude. This model was applied for determining optimum tilt angle and orientation in the tropical zones, on a daily basis, as well as for a specific period. The optimum angle was computed by searching for the values for which the radiation on the collector surface is a maximum for a particular day or a specific period. The results reveal that changing the tilt angle 12 times in a year (i.e. using the monthly optimum tilt angle maintains approximately the total amount of solar radiation near the maximum value that is found by changing the tilt angle daily to its optimum value. This achieves a yearly gain in solar radiation of 11% to 18% more than the case of a solar collector fixed on a horizontal surface.

  4. Experimental Study of an SWH System with V-Shaped Plate

    Directory of Open Access Journals (Sweden)

    Jalaluddin

    2016-05-01

    Full Text Available Solar energy is known as an environmentally friendly energy source with a wide range of applications. This energy can be utilized in various applications such as domestic and industrial water heating using solar water heating (SWH systems. The thermal performance of an SWH system using a V-shaped absorber plate is presented in this study. Two SWH systems with different absorber plates, i.e. a flat-plate and a V-shaped plate, have been investigated experimentally. First, the absorptivity of the absorber plates was calculated analytically. The optimum V-shaped configuration with angle at β = 21° (V-shaped dimensions t = 4 cm and l = 4 cm was determined from various V-shaped plate absorbers based on their absorptivity and applied in the experimental study. Two SWH systems were installed and tested at a low flowrate of 0.5 L/min and at a high flowrate of 2 L/min. The results showed that the SWH system with V-shaped plate absorber had a 3.6-4.4% better performance compared with that of the system with flat-plate absorber.

  5. [Stereomodel-assisted fibula free flap harvest and mandibular reconstruction: A technical note. Literature review of CAS and CAM applied to mandibular reconstruction.

    Science.gov (United States)

    Pauchot, J; Lachat, J; Floret, F; Badet, J-M; Tavernier, L; Aubry, S

    2013-08-05

    Mandibular reconstruction with fibula free flap harvest is currently the reference technique. Various preoperative processes have been developed to optimize this reconstruction. We report our experience with a simple, inexpensive, preoperative technique requiring a 3D printer, a device for maintaining mandibular reduction, a paper-cutting guide. Stereomodels of the mandible were obtained from computed tomography scan data and printed 3D in ABS. It allowed planning mandibular osteotomies, determine the angle between two bone fragments, and preoperatively modeling the osteosynthesis plate. A paper-cutting guide, and a simple device for maintaining mandibular reduction were also built. Two patients were operated on with this technique, with follow-up at 6 and 8 months. Reconstructions were successful with good clinical outcome in terms of mandibular contour and reconstructed segments positions. Preoperative planning of reconstruction may be used for mandibular osteotomies, fibular osteotomies, maintaining mandibular reduction, osteosynthesis, or placing implants for dental rehabilitation. The most complex procedures can virtually plan all these steps, but they are expensive and long to implement. Nevertheless, such procedures are quite expansive and require time not always compatible with carcinoma. Using a mandibular stereomodel is fast, easy, and cheap. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  6. Buckling and postbuckling behavior of square compression-loaded graphite-epoxy plates with circular cutouts

    Science.gov (United States)

    Nemeth, Michael P.

    1990-01-01

    Results are presented for unidirectional (0, 10)(sub s) and (90,10)(sub s) plates, ((0/90)(sub 5)(sub s)) plates, and for aluminum plates. Results are also presented for ((+/- theta)(sub 6)(sub s)) angle-ply plates for values of theta = 30, 45, and 60 degrees. The results indicate that the change in axial stiffness of a plate at buckling is strongly dependent upon cutout size and plate orthotropy. The presence of a cutout gives rise to an internal load distribution that changes, sometimes dramatically, as a function of cutout size coupled with the plate orthotropy. In the buckled state, the role of orthotropy becomes more significant since bending in addition to membrane orthotropy is present. Most of the plates with cutouts exhibited less postbuckling stiffness than the corresponding plate without a cutout, and the postbuckling stiffness decreased with increasing cutout size. However, some of the highly orthotropic plates with cutouts exhibited more postbuckling stiffness than the corresponding plate without a cutout. These results suggest the possibility of tailoring the cutout size and the stacking sequence of a composite plate to optimize postbuckling stiffness. It was found that plates with large radius cutouts do exhibit some postbuckling strength. The results also indicate that a cutout can influence modal interaction in a plate. Specifically, results are presented that show a plate with a relatively small cutout buckling at a higher load than the corresponding plate without a cutout, due to modal interaction. Other results are presented that indicate the presence of nonlinear prebuckling deformations, due to material nonlinearity, in the angle-ply plates with theta = 45 and 60 degrees. The nonlinear prebuckling deformations are more pronounced in the plates with theta = 45 degrees and become even more pronounced as the cutout size increases. Results are also presented that show how load-path eccentricity due to improper machining of the test specimens

  7. Does the Angle of the Nail Matter for Pertrochanteric Fracture Reduction? Matching Nail Angle and Native Neck-Shaft Angle.

    Science.gov (United States)

    Parry, Joshua A; Barrett, Ian; Schoch, Bradley; Yuan, Brandon; Cass, Joseph; Cross, William

    2018-04-01

    To determine whether fixation of pertrochanteric hip fractures with cephalomedullary nails (CMNs) with a neck-shaft angle (NSA) less than the native NSA affects reduction and lag screw cutout. Retrospective comparative study. Level I trauma center. Patients treated with a CMN for unstable pertrochanteric femur fractures (OTA/AO 31-A2.2 and 31-A2.3) between 2005 and 2014. CMN fixation. NSA reduction and lag screw cutout. Patients fixed with a nail angle less than their native NSA were less likely to have good reductions [17% vs. 60%, 95% confidence interval (CI), -63% to -18%; P = 0.0005], secondary to more varus reductions (41% vs. 10%, 95% CI, 9%-46%; P = 0.01) and more fractures with ≥4 mm of displacement (63% vs. 35%, 95% CI, 3%-49%; P = 0.03). The cutout was not associated with the use of a nail angle less than the native NSA (60% vs. 76%, 95% CI, -56% to 18%; P = 0.5), varus reductions (60% vs. 32%, 95% CI, -13% to 62%; P = 0.3), or poor reductions (20% vs. 17%, 95% CI, -24% to 44%; P = 1.0). The fixation of unstable pertrochanteric hip fractures with a nail angle less than the native NSA was associated with more varus reductions and fracture displacement but did not affect the lag screw cutout. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  8. Small Angle X-Ray Scattering Detector

    Energy Technology Data Exchange (ETDEWEB)

    Hessler, Jan P.

    2004-06-15

    A detector for time-resolved small-angle x-ray scattering includes a nearly constant diameter, evacuated linear tube having an end plate detector with a first fluorescent screen and concentric rings of first fiber optic bundles for low angle scattering detection and an annular detector having a second fluorescent screen and second fiber optic bundles concentrically disposed about the tube for higher angle scattering detection. With the scattering source, i.e., the specimen under investigation, located outside of the evacuated tube on the tube's longitudinal axis, scattered x-rays are detected by the fiber optic bundles, to each of which is coupled a respective photodetector, to provide a measurement resolution, i.e., dq/q, where q is the momentum transferred from an incident x-ray to an x-ray scattering specimen, of 2% over two (2) orders of magnitude in reciprocal space, i.e., qmax/qmin approx=lO0.

  9. Optimal tilt-angles for solar collectors used in China

    International Nuclear Information System (INIS)

    Tang Runsheng; Wu Tong

    2004-01-01

    A reasonable estimation of the optimal tilt angle of a fixed collector for maximizing its energy collection must be done based on the monthly global and diffuse radiation on a horizontal surface. However, the monthly diffuse radiation is not always available in many places. In this paper, a simple mathematical procedure for the estimation of the optimal tilt angle of a collector is presented based on the monthly horizontal radiation. A comparison of the optimal tilt angles of collectors obtained from expected monthly diffuse radiation and that from the actual monthly diffuse radiation showed that this method gives a good estimation of the optimal tilt angle, except for places with a considerably lower clearness index. A contour map of the optimal tilt angle of the south-facing collectors used for the entire year in China is also outlined, based on monthly horizontal radiation of 152 places around the country, combing the optimal tilt angle of another 30 cities based on the actual monthly diffuse radiation

  10. Computational modelling of long bone fractures fixed with locking plates - How can the risk of implant failure be reduced?

    LENUS (Irish Health Repository)

    Nassiri, M

    2013-03-01

    The Locking Compression Plate (LCP) is part of a new plate generation requiring an adapted surgical technique and new thinking about commonly used concepts of internal fixation using plates. Knowledge of the fixation stability provided by these new plates is very limited and clarification is still necessary to determine how the mechanical stability and the risk of implant failure can best be controlled.

  11. [Clinical experience with various techniques integrated treat the wounded with gunshot fractures of limbs].

    Science.gov (United States)

    Kozlov, V K; Akhmedov, B G; Chililov, A M

    To increase an efficiency of complex treatment of patients with diaphyseal gunshot fractures of long bones by introduction of modern minimally invasive surgical techniques of internal osteosynthesis into clinical practice of civil health care and to improve the outcomes in victims. Prospective comparative clinical trial included 104 victims from the Republic of Yemen with gunshot wounds of limbs of various severity for the period 2009-2011. There were diaphyseal fractures of long bones of limbs associated with soft tissue injuries. Men were predominant (80.7%). Age ranged from 15 to 80 years (mean 38,5 ± 5,7 years). Various surgical techniques of simultaneous and staged treatment were used for gunshot fractures of long bones of limbs. Additional immune therapy was prescribed to prevent infectious complications in the most severe cases. Victims were comprehensively treated according to different staged treatment: conventional surgical treatment with external fixation devices or early primary minimally invasive functionally stable osteosynthesis with LCP/BIOS plates were applied for low-energy fractures; in case of high-energy fractures the first stage included external fixation devices deployment followed by their subsequent replacement during delayed minimally invasive osteosynthesis. The essence of improvement is pursuit to simultaneous minimally invasive surgery by using of current plates for osteosynthesis and preventive immunotherapy of immune dysfunction to eliminate infectious complications. As a result, we obtained 2-fold decrease of surgical invasiveness (r≤0,01) and hospital-stay (r≤0,01). Repeated osteosynthesis was not made. Also 4-fold and 40-fold reduction of infectious and noninfectious complications was observed. This management was accompanied by reduced rehabilitation tine and significantly improved quality of life. Improved technique and algorithm of complex treatment of diaphyseal gunshot fractures of long bones of limbs were described

  12. Epidemiology and treatment outcome of surgically treated mandibular condyle fractures. A five years retrospective study.

    Science.gov (United States)

    Zrounba, Hugues; Lutz, Jean-Christophe; Zink, Simone; Wilk, Astrid

    2014-09-01

    Surgical management of mandibular condyle fractures is still controversial. Although it provides better outcome than closed treatment questions still remain about the surgical approach and the osteosynthesis devices to be used. Between 2005 and 2010, we managed 168 mandibular condyle fractures with open treatment. Two surgical approaches were used in this study, a pre-auricular and a high submandibular approach (one or the other or as a combined approach). Internal fixation was performed using TCP(®) plates (Medartis, Basel, Switzerland) or with two lag screws (15 and 17 mm). Delta plates were used in 15 cases (8.9%). We report the epidemiology of these fractures and the outcomes of the surgical treatment. We assessed the complications related to the surgical procedure and those related to the osteosynthesis material. The facial nerve related complication rate was very low and the osteosynthesis materials used proved to be strong enough to realize a stable fixation. The two approaches used in this study appeared to be safe with good aesthetic results. Most of the surgical procedure failures occurred in high subcondylar fractures especially when bilateral. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  13. Modeling contact angle hysteresis of a liquid droplet sitting on a cosine wave-like pattern surface.

    Science.gov (United States)

    Promraksa, Arwut; Chen, Li-Jen

    2012-10-15

    A liquid droplet sitting on a hydrophobic surface with a cosine wave-like square-array pattern in the Wenzel state is simulated by using the Surface Evolver to determine the contact angle. For a fixed drop volume, multiple metastable states are obtained at two different surface roughnesses. Unusual and non-circular shape of the three-phase contact line of a liquid droplet sitting on the model surface is observed due to corrugation and distortion of the contact line by structure of the roughness. The contact angle varies along the contact line for each metastable state. The maximum and minimum contact angles among the multiple metastable states at a fixed viewing angle correspond to the advancing and the receding contact angles, respectively. It is interesting to observe that the advancing/receding contact angles (and contact angle hysteresis) are a function of viewing angle. In addition, the receding (or advancing) contact angles at different viewing angles are determined at different metastable states. The contact angle of minimum energy among the multiple metastable states is defined as the most stable (equilibrium) contact angle. The Wenzel model is not able to describe the contact angle along the three-phase contact line. The contact angle hysteresis at different drop volumes is determined. The number of the metastable states increases with increasing drop volume. Drop volume effect on the contact angles is also discussed. Crown Copyright © 2012. Published by Elsevier Inc. All rights reserved.

  14. Using external and internal locking plates in a two-stage protocol for treatment of segmental tibial fractures.

    Science.gov (United States)

    Ma, Ching-Hou; Tu, Yuan-Kun; Yeh, Jih-Hsi; Yang, Shih-Chieh; Wu, Chin-Hsien

    2011-09-01

    The tibial segmental fractures usually follow high-energy trauma and are often associated with many complications. We designed a two-stage protocol for these complex injuries. The aim of this study was to assess the outcome of tibial segmental fractures treated according to this protocol. A prospective series of 25 consecutive segmental tibial fractures were treated using a two-stage procedure. In the first stage, a low-profile locking plate was applied as an external fixator to temporarily immobilize the fractures after anatomic reduction had been achieved followed by soft-tissue reconstruction. The second stage involved definitive internal fixation with a locking plate using a minimally invasive percutaneous plate osteosynthesis technique. The median follow-up was 32 months (range, 20-44 months). All fractures achieved union. The median time for the proximal fracture union was 23 weeks (range, 12-30 weeks) and that for distal fracture union was 27 weeks (range, 12-46 weeks; p = 0.08). Functional results were excellent in 21 patients and good in 4 patients. There were three cases of delayed union of distal fracture. Valgus malunion >5 degrees occurred in two patients, and length discrepancy >1 cm was observed in two patients. Pin tract infection occurred in three patients. Use of the two-stage procedure for treatment of segmental tibial fractures is recommended. Surgeons can achieve good reduction with stable temporary fixation, soft-tissue reconstruction, ease of subsequent definitive fixation, and high union rates. Our patients obtained excellent knee and ankle joint motion, good functional outcomes, and a comfortable clinical course.

  15. Autogenous cultured growth plate chondrocyte transplantation in the treatment of physeal injury in rabbits.

    Science.gov (United States)

    Tomaszewski, R; Bohosiewicz, J; Gap, A; Bursig, H; Wysocka, A

    2014-11-01

    The aim of this experimental study on New Zealand's white rabbits was to investigate the transplantation of autogenous growth plate cells in order to treat the injured growth plate. They were assessed in terms of measurements of radiological tibial varus and histological characteristics. An experimental model of plate growth medial partial resection of the tibia in 14 New Zealand white rabbits was created. During this surgical procedure the plate growth cells were collected and cultured. While the second surgery was being performed, the autologous cultured growth plate cells were grafted at the right tibia, whereas the left tibia was used as a control group. Histological examinations showed that the grafted right tibia presented the regular shape of the plate growth with hypertrophic maturation, chondrocyte columniation and endochondral calcification. Radiological study shows that the mean tibial deformity at the left angle was 20.29° (6.25 to 33) and 7.21° (5 to 10) in the right angle. This study has demonstrated that grafting of autogenous cultured growth plate cells into a defect of the medial aspect of the proximal tibial physis can prevent bone bridge formation, growth arrest and the development of varus deformity. Cite this article: Bone Joint Res 2014;3:310-16. ©2014 The British Editorial Society of Bone & Joint Surgery.

  16. Optical superimposed vortex beams generated by integrated holographic plates with blazed grating

    Science.gov (United States)

    Zhang, Xue-Dong; Su, Ya-Hui; Ni, Jin-Cheng; Wang, Zhong-Yu; Wang, Yu-Long; Wang, Chao-Wei; Ren, Fei-Fei; Zhang, Zhen; Fan, Hua; Zhang, Wei-Jie; Li, Guo-Qiang; Hu, Yan-Lei; Li, Jia-Wen; Wu, Dong; Chu, Jia-Ru

    2017-08-01

    In this paper, we demonstrate that the superposition of two vortex beams with controlled topological charges can be realized by integrating two holographic plates with blazed grating. First, the holographic plate with blazed grating was designed and fabricated by laser direct writing for generating well-separated vortex beam. Then, the relationship between the periods of blazed grating and the discrete angles of vortex beams was systemically investigated. Finally, through setting the discrete angle and different revolving direction of the holographic plates, the composite fork-shaped field was realized by the superposition of two vortex beams in a particular position. The topological charges of composite fork-shaped field (l = 1, 0, 3, and 4) depend on the topological charges of compositional vortex beams, which are well agreed with the theoretical simulation. The method opens up a wide range of opportunities and possibilities for applying in optical communication, optical manipulations, and photonic integrated circuits.

  17. Study the effect of chemical reaction and variable viscosity on free convection MHD radiating flow over an inclined plate bounded by porous medium

    Energy Technology Data Exchange (ETDEWEB)

    Ali, M., E-mail: ali.mehidi93@gmail.com [Department of Mathematics, Bangladesh University of Engineering and Technology, Dhaka-1000 (Bangladesh); Department of Mathematics, Chittagong University of Engineering and Technology, Chittagong-4349 (Bangladesh); Alim, M. A., E-mail: maalim@math.buet.ac.bd; Nasrin, R., E-mail: rehena@math.buet.ac.bd [Department of Mathematics, Bangladesh University of Engineering and Technology, Dhaka-1000 (Bangladesh); Alam, M. S., E-mail: shahalammaths@gmail.com [Department of Mathematics, Chittagong University of Engineering and Technology, Chittagong-4349 (Bangladesh)

    2016-07-12

    An analysis is performed to study the free convection heat and mass transfer flow of an electrically conducting incompressible viscous fluid about a semi-infinite inclined porous plate under the action of radiation, chemical reaction in presence of magnetic field with variable viscosity. The dimensionless governing equations are steady, two-dimensional coupled and non-linear ordinary differential equation. Nachtsgeim-Swigert shooting iteration technique along with Runge-Kutta integration scheme is used to solve the non-dimensional governing equations. The effects of magnetic parameter, viscosity parameter and chemical reaction parameter on velocity, temperature and concentration profiles are discussed numerically and shown graphically. Therefore, the results of velocity profile decreases for increasing values of magnetic parameter and viscosity parameter but there is no effect for reaction parameter. The temperature profile decreases in presence of magnetic parameter, viscosity parameter and Prandtl number but increases for radiation parameter. Also, concentration profile decreases for the increasing values of magnetic parameter, viscosity parameter and reaction parameter. All numerical calculations are done with respect to salt water and fixed angle of inclination of the plate.

  18. Study the effect of chemical reaction and variable viscosity on free convection MHD radiating flow over an inclined plate bounded by porous medium

    International Nuclear Information System (INIS)

    Ali, M.; Alim, M. A.; Nasrin, R.; Alam, M. S.

    2016-01-01

    An analysis is performed to study the free convection heat and mass transfer flow of an electrically conducting incompressible viscous fluid about a semi-infinite inclined porous plate under the action of radiation, chemical reaction in presence of magnetic field with variable viscosity. The dimensionless governing equations are steady, two-dimensional coupled and non-linear ordinary differential equation. Nachtsgeim-Swigert shooting iteration technique along with Runge-Kutta integration scheme is used to solve the non-dimensional governing equations. The effects of magnetic parameter, viscosity parameter and chemical reaction parameter on velocity, temperature and concentration profiles are discussed numerically and shown graphically. Therefore, the results of velocity profile decreases for increasing values of magnetic parameter and viscosity parameter but there is no effect for reaction parameter. The temperature profile decreases in presence of magnetic parameter, viscosity parameter and Prandtl number but increases for radiation parameter. Also, concentration profile decreases for the increasing values of magnetic parameter, viscosity parameter and reaction parameter. All numerical calculations are done with respect to salt water and fixed angle of inclination of the plate.

  19. A study of the apsidal angle and a proof of monotonicity in the logarithmic potential case

    NARCIS (Netherlands)

    Castelli, Roberto

    2014-01-01

    This paper concerns the behaviour of the apsidal angle for orbits of central force system with homogeneous potential of degree -2 ≤ α ≤ 1 and logarithmic potential. We derive a formula for the apsidal angle as a fixed end-points integral and we study the derivative of the apsidal angle with respect

  20. Transmission type Sc/Cr multilayers as a quarter-wave plate for 398.6 eV

    International Nuclear Information System (INIS)

    Kimura, H.; Hirono, T.; Tamenori, Y.; Saitoh, Y.; Salashchenko, N.N.; Ishikawa, T.

    2004-01-01

    Full text: Full polarization measurement using a phase shifter and a polarizer is needed to determine the degree of circular polarization. A quarter-wave plate, which is a phase shifter having retardation of 90 deg., is especially desired for accurate determination of the full polarization measurement for highly circularly polarized light. In the soft x-ray region, a self-standing multilayer with high reflectance can be used as a phase shifter having large retardation angle under transmission geometry. In this region, Mo/Si multilayer has been reported as a quarter-wave plate for photon energy of 97 eV. To perform the full polarization measurement in higher photon energy, we newly developed a quarter-wave plate by transmission type Sc/Cr multilayer. Polarization characteristics of the multilayer were measured by mean of rotating analyzer ellipsometry method using a linearly polarized SR of 398.6 eV. Figure 1 shows the retardation of the multilayer (Sc/Cr, d = 3.15 nm, 300 pairs). As is shown the phase shifter can be used as a quarter-wave plate at the incident angle of 59.7 deg. At this angle its transmittance for p-component and the ratio of those for p- and s-component were 0.4 % and 1.47, respectively

  1. Determination of transfer parameters in corrugated plates exchangers

    International Nuclear Information System (INIS)

    Silva Lima Filho, S. da.

    1984-01-01

    In this work is presented a experimental study about the forced convenction problem in vee-corrugated exchangers, with flow in the transversal sense, and parallel plates exchangers in which the isotermal plate is equivalent to the absobing one and the other plate is adiabatic. Global values of the transfer coefficients were experimentally obtained by application of the Naphthalene Sublimation Technique in accordance with the analogy between heat and mass transfer. The results were expressed in terms of Sh sup(-) /Sc sup(0,4) that according to the analogy is equal the Nu sup(-) / Pr sup(0,4) in function of the Reynolds number. The ratio between the lenght of the channel and the average spacing between plates L/2a was ranged in all the exchangers. Parameters of transfer to angles of 45 0 and 31 0 were determined in the corrugated plates exchangers. The experimental results obtained were analyzed and compared among them. Finally practical applications of these results are presented to heat exchangers with similars geometric characteristics. (Author) [pt

  2. Sun-view angle effects on reflectance factors of corn canopies

    Science.gov (United States)

    Ranson, K. J.; Daughtry, C. S. T.; Biehl, L. L.; Bauer, M. E.

    1985-01-01

    The effects of sun and view angles on reflectance factors of corn (Zea mays L.) canopies ranging from the six leaf stage to harvest maturity were studied on the Purdue University Agronomy Farm by a multiband radiometer. The two methods of acquiring spectral data, the truck system and the tower systrem, are described. The analysis of the spectral data is presented in three parts: solar angle effects on reflectance factors viewed at nadir; solar angle effects on reflectance factors viewed at a fixed sun angle; and both sun and view angles effect on reflectance factors. The analysis revealed that for nadir-viewed reflectance factors there is a strong solar angle dependence in all spectral bands for canopies with low leaf area index. Reflectance factors observed from the sun angle at different view azimuth angles showed that the position of the sensor relative to the sun is important in determining angular reflectance characteristics. For both sun and view angles, reflectance factors are maximized when the sensor view direction is towards the sun.

  3. Effects of Volar Tilt, Wrist Extension, and Plate Position on Contact Between Flexor Pollicis Longus Tendon and Volar Plate.

    Science.gov (United States)

    Wurtzel, Caroline N Wolfe; Burns, Geoffrey T; Zhu, Andy F; Ozer, Kagan

    2017-12-01

    Volar plates positioned at, or distal to, the watershed line have been shown to have a higher incidence of attritional rupture of the flexor pollicis longus (FPL). In this study, we aimed to evaluate the effect of wrist extension and volar tilt on the contact between the plate and the FPL tendon in a cadaver model. We hypothesized that, following volar plate application, loss of native volar tilt increases the contact between the FPL and the plate at lower degrees of wrist extension. A volar locking plate was applied on 6 fresh-frozen cadavers. To determine the contact between the plate and the FPL tendon, both structures were wrapped with copper wire and circuit conductivity was monitored throughout wrist motion. A lateral wrist radiograph was obtained at each circuit closure, indicating tendon-plate contact. Baseline measurements were obtained with plate positioned at Soong grades 0, 1, and 2. An extra-articular osteotomy was made and contact was recorded at various volar tilt angles (+5°, 0°, -5°, -10°, -15°, and -20°) in 3 different plate positions. A blinded observer measured the degree of wrist extension on all lateral radiographs. Data were analyzed using linear mixed-effects regression model. Plates placed distal to the watershed line had the most contact throughout wrist range of motion. Significantly, less wrist extension was required for contact in wrists with neutral or dorsal tilt and in distally placed volar plates. Volar tilt, wrist extension, and plate position were 3 independent risk factors determining contact between plate and tendon. Loss of volar tilt, increased wrist extension, and higher Soong grade plate position result in greater contact between wire-wrapped FPL tendon and plate. The FPL/plate contact chart generated in this study may be used to assess the risk of rupture in the clinical setting. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  4. Fabrication of Hydrophobic Surface on Wood Veneer via Electroless Nickel Plating Combined with Chemical Corrosion

    Directory of Open Access Journals (Sweden)

    Zhaojun Tang

    2015-12-01

    Full Text Available Birch veneers were coated with Ni-P films by a combined process of KBH4 activation and electroless plating. The plated veneers were further chemically corroded to obtain hydrophobic surfaces on wood. The effect of chemical corrosion on the contact angle of the veneers was investigated. The hydrophobic veneers were characterized by X-ray photo electron spectroscopy (XPS, scanning electron microscopy (SEM, and X-ray diffraction (XRD. The surface contact angle of birch veneer before and after it was plated with Ni-P alloy coating was 41º and 121º, respectively. The contact angle reached 136.7º when the nickel-coated veneers were corroded in CuSO4 aqueous solution for 30 min. XPS analysis showed that Cu0 cluster doped with little CuO formed on the corroded surface of Ni-P alloy film after chemical corrosion. SEM and XRD showed that rough copper clusters formed on the surface of the wood veneer and revealed the reason of the surface hydrophobicity. This study provides a new pathway for fabricating hydrophobic wood.

  5. Absolute Calibration of Image Plate for electrons at energy between 100 keV and 4 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Chen, H; Back, N L; Eder, D C; Ping, Y; Song, P M; Throop, A

    2007-12-10

    The authors measured the absolute response of image plate (Fuji BAS SR2040) for electrons at energies between 100 keV to 4 MeV using an electron spectrometer. The electron source was produced from a short pulse laser irradiated on the solid density targets. This paper presents the calibration results of image plate Photon Stimulated Luminescence PSL per electrons at this energy range. The Monte Carlo radiation transport code MCNPX results are also presented for three representative incident angles onto the image plates and corresponding electron energies depositions at these angles. These provide a complete set of tools that allows extraction of the absolute calibration to other spectrometer setting at this electron energy range.

  6. Generalized viscothermoelasticity theory of dual-phase-lagging model for damping analysis in circular micro-plate resonators

    Science.gov (United States)

    Grover, D.; Seth, R. K.

    2018-05-01

    Analysis and numerical results are presented for the thermoelastic dissipation of a homogeneous isotropic, thermally conducting, Kelvin-Voigt type circular micro-plate based on Kirchhoff's Love plate theory utilizing generalized viscothermoelasticity theory of dual-phase-lagging model. The analytical expressions for thermoelastic damping of vibration and frequency shift are obtained for generalized dual-phase-lagging model and coupled viscothermoelastic plates. The scaled thermoelastic damping has been illustrated in case of circular plate and axisymmetric circular plate for fixed aspect ratio for clamped and simply supported boundary conditions. It is observed that the damping of vibrations significantly depend on time delay and mechanical relaxation times in addition to thermo-mechanical coupling in circular plate under resonance conditions and plate dimensions.

  7. Indonesian Landforms and Plate Tectonics

    Directory of Open Access Journals (Sweden)

    Herman Th. Verstappen

    2014-06-01

    Full Text Available DOI: 10.17014/ijog.v5i3.103The horizontal configuration and vertical dimension of the landforms occurring in the tectonically unstable parts of Indonesia were resulted in the first place from plate tectonics. Most of them date from the Quaternary and endogenous forces are ongoing. Three major plates – the northward moving Indo-Australian Plate, the south-eastward moving SE-Asian Plate and the westward moving Pacific Plate - meet at a plate triple-junction situated in the south of New Guinea’s Bird’s Head. The narrow North-Moluccan plate is interposed between the Asia and Pacific. It tapers out northward in the Philippine Mobile Belt and is gradually disappearing. The greatest relief amplitudes occur near the plate boundaries: deep ocean trenches are associated with subduction zones and mountain ranges with collision belts. The landforms of the more stable areas of the plates date back to a more remote past and, where emerged, have a more subdued relief that is in the first place related to the resistance of the rocks to humid tropical weathering Rising mountain ranges and emerging island arcs are subjected to rapid humid-tropical river erosions and mass movements. The erosion products accumulate in adjacent sedimentary basins where their increasing weight causes subsidence by gravity and isostatic compensations. Living and raised coral reefs, volcanoes, and fault scarps are important geomorphic indicators of active plate tectonics. Compartmental faults may strongly affect island arcs stretching perpendicular to the plate movement. This is the case on Java. Transcurrent faults and related pull-apart basins are a leading factor where plates meet at an angle, such as on Sumatra. The most complicated situation exists near the triple-junction and in the Moluccas. Modern research methods, such as GPS measurements of plate movements and absolute dating of volcanic outbursts and raised coral reefs are important tools. The mega-landforms resulting

  8. FUNCTIONAL OUTCOME OF SUPRACONDYLAR FRACTURES OF FEMUR MANAGED BY OPEN REDUCTION AND INTERNAL FIXATION WITH LOCKING COMPRESSION PLATE

    Directory of Open Access Journals (Sweden)

    Madhusudhana

    2015-10-01

    , avoidance of stress shielding and induction of callus formation. Further when it is applied via a minimally invasive technique, it allows for prompt healing, lower rates of infection and reduced bone re sorption as blood supply is preserved. 9 , 10 The implant offers multiple points of fixed - angle contact between the plate and screws in the distal part of femur, theoretically reducing the tendency for varus collapse that is seen with traditional lateral plates

  9. Thermoelastic buckling of plates in a cylindrical geometry against an elastic back support

    International Nuclear Information System (INIS)

    Simmons, L.D.; Wierman, R.W.

    1980-01-01

    A plate which is fixed at its edges to a strong edge support structure will develop large compressive stresses when heated from ambient temperature more rapidly than the support structure. Determining the response of the plate to this situation requires stability analysis to ascertain whether the plate might buckle, or whether the constrained thermal expansion will lead to compressive stresses exceeding the yield point because it did not buckle. A special case is considered here, both analytically and experimentally, in which the plate is curved slightly into a cylindrical shape and the convex face of the plate is against a supporting surface. This case is more complex because the buckling mode will be a harmonic rather than the fundamental mode which is usually encountered

  10. Steiner trees for fixed orientation metrics

    DEFF Research Database (Denmark)

    Brazil, Marcus; Zachariasen, Martin

    2009-01-01

    We consider the problem of constructing Steiner minimum trees for a metric defined by a polygonal unit circle (corresponding to s = 2 weighted legal orientations in the plane). A linear-time algorithm to enumerate all angle configurations for degree three Steiner points is given. We provide...... a simple proof that the angle configuration for a Steiner point extends to all Steiner points in a full Steiner minimum tree, such that at most six orientations suffice for edges in a full Steiner minimum tree. We show that the concept of canonical forms originally introduced for the uniform orientation...... metric generalises to the fixed orientation metric. Finally, we give an O(s n) time algorithm to compute a Steiner minimum tree for a given full Steiner topology with n terminal leaves....

  11. Small angle elastic scattering of electrons by noble gas atoms

    International Nuclear Information System (INIS)

    Wagenaar, R.W.

    1984-01-01

    In this thesis, measurements are carried out to obtain small angle elastic differential cross sections in order to check the validity of Kramers-Kronig dispersion relations for electrons scattered by noble gas atoms. First, total cross sections are obtained for argon, krypton and xenon. Next, a parallel plate electrostatic energy analyser for the simultaneous measurement of doubly differential cross section for small angle electron scattering is described. Also absolute differential cross sections are reported. Finally the forward dispersion relation for electron-helium collisions is dealt with. (Auth.)

  12. Improving greater trochanteric reattachment with a novel cable plate system.

    Science.gov (United States)

    Baril, Yannick; Bourgeois, Yan; Brailovski, Vladimir; Duke, Kajsa; Laflamme, G Yves; Petit, Yvan

    2013-03-01

    Cable-grip systems are commonly used for greater trochanteric reattachment because they have provided the best fixation performance to date, even though they have a rather high complication rate. A novel reattachment system is proposed with the aim of improving fixation stability. It consists of a Y-shaped fixation plate combined with locking screws and superelastic cables to reduce cable loosening and limit greater trochanter movement. The novel system is compared with a commercially available reattachment system in terms of greater trochanter movement and cable tensions under different greater trochanteric abductor application angles. A factorial design of experiments was used including four independent variables: plate system, cable type, abductor application angle, and femur model. The test procedure included 50 cycles of simultaneous application of an abductor force on the greater trochanter and a hip force on the femoral head. The novel plate reduces the movements of a greater trochanter fragment within a single loading cycle up to 26%. Permanent degradation of the fixation (accumulated movement based on 50-cycle testing) is reduced up to 46%. The use of superelastic cables reduces tension loosening up to 24%. However this last improvement did not result in a significant reduction of the grater trochanter movement. The novel plate and cables present advantages over the commercially available greater trochanter reattachment system. The plate reduces movements generated by the hip abductor. The superelastic cables reduce cable loosening during cycling. Both of these positive effects could decrease the risks related to grater trochanter non-union. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  13. Relative range error evaluation of terrestrial laser scanners using a plate, a sphere, and a novel dual-sphere-plate target.

    Science.gov (United States)

    Muralikrishnan, Bala; Rachakonda, Prem; Lee, Vincent; Shilling, Meghan; Sawyer, Daniel; Cheok, Geraldine; Cournoyer, Luc

    2017-12-01

    Terrestrial laser scanners (TLS) are a class of 3D imaging systems that produce a 3D point cloud by measuring the range and two angles to a point. The fundamental measurement of a TLS is range. Relative range error is one component of the overall range error of TLS and its estimation is therefore an important aspect in establishing metrological traceability of measurements performed using these systems. Target geometry is an important aspect to consider when realizing the relative range tests. The recently published ASTM E2938-15 mandates the use of a plate target for the relative range tests. While a plate target may reasonably be expected to produce distortion free data even at far distances, the target itself needs careful alignment at each of the relative range test positions. In this paper, we discuss relative range experiments performed using a plate target and then address the advantages and limitations of using a sphere target. We then present a novel dual-sphere-plate target that draws from the advantages of the sphere and the plate without the associated limitations. The spheres in the dual-sphere-plate target are used simply as fiducials to identify a point on the surface of the plate that is common to both the scanner and the reference instrument, thus overcoming the need to carefully align the target.

  14. Biomechanical investigation of an alternative concept to angular stable plating using conventional fixation hardware.

    Science.gov (United States)

    Windolf, Markus; Klos, Kajetan; Wähnert, Dirk; van der Pol, Bas; Radtke, Roman; Schwieger, Karsten; Jakob, Roland P

    2010-05-21

    Angle-stable locking plates have improved the surgical management of fractures. However, locking implants are costly and removal can be difficult. The aim of this in vitro study was to evaluate the biomechanical performance of a newly proposed crossed-screw concept ("Fence") utilizing conventional (non-locked) implants in comparison to conventional LC-DCP (limited contact dynamic compression plate) and LCP (locking compression plate) stabilization, in a human cadaveric diaphyseal gap model. In eight pairs of human cadaveric femora, one femur per pair was randomly assigned to receive a Fence construct with either elevated or non-elevated plate, while the contralateral femur received either an LCP or LC-DCP instrumentation. Fracture gap motion and fatigue performance under cyclic loading was evaluated successively in axial compression and in torsion. Results were statistically compared in a pairwise setting. The elevated Fence constructs allowed significantly higher gap motion compared to the LCP instrumentations (axial compression: p concept can be of interest in cases were angle-stable implants are unavailable and can lead to new strategies in implant design.

  15. Effect of a standardized treatment regime for infection after osteosynthesis.

    Science.gov (United States)

    Hellebrekers, Pien; Leenen, Luke P H; Hoekstra, Meriam; Hietbrink, Falco

    2017-03-09

    Infection after osteosynthesis is an important complication with significant morbidity and even mortality. These infections are often caused by biofilm-producing bacteria. Treatment algorithms dictate an aggressive approach with surgical debridement and antibiotic treatment. The aim of this study is to analyze the effect of such an aggressive standardized treatment regime with implant retention for acute, existing regime consisted of implant retention, thorough surgical debridement, and immediate antibiotic combination therapy with rifampicin. The primary outcome was success. Success was defined as consolidation of the fracture and resolved symptoms of infection. Culture and susceptibility testing were performed to identify bacteria and resistance patterns. Univariate analysis was conducted on patient-related factors in association with primary success and antibiotic resistance. Forty-nine patients were included for analysis. The primary success rate was 63% and overall success rate 88%. Factors negatively associated with primary success were the following: Gustilo classification (P = 0.023), higher number of debridements needed (P = 0.015), inability of primary closure (P = 0.017), and subsequent application of vacuum therapy (P = 0.030). Adherence to the treatment regime was positively related to primary success (P = 0.034). The described treatment protocol results in high success rates, comparable with success rates achieved in staged exchange in prosthetic joint infection treatment.

  16. Mixed convection flow past a horizontal plate

    Directory of Open Access Journals (Sweden)

    Savić Lj.

    2005-01-01

    Full Text Available The mixed convection flow past a horizontal plate being aligned through a small angle of attack to a uniform free stream will be considered in the limit of large Reynolds number and small Richardson number. Even a small angle of inclination of the wake is sufficient for the buoyancy force to accelerate the flow in the wake which causes a velocity overshoot in the wake. Moreover a hydrostatic pressure difference across the wake induces a correction to the potential flow which influences the inclination of the wake. Thus the wake and the correction of the potential flow have to be determined simultaneously. However, it turns out that solutions exist only if the angle of attack is sufficiently large. Solutions are computed numerically and the influence of the buoyancy on the lift coefficient is determined.

  17. Evaluation of Bone Atrophy After Treatment of Forearm Fracture Using Nonlinear Finite Element Analysis: A Comparative Study of Locking Plates and Conventional Plates.

    Science.gov (United States)

    Matsuura, Yusuke; Rokkaku, Tomoyuki; Suzuki, Takane; Thoreson, Andrew Ryan; An, Kai-Nan; Kuniyoshi, Kazuki

    2017-08-01

    Forearm diaphysis fractures are usually managed by open reduction internal fixation. Recently, locking plates have been used for treatment. In the long-term period after surgery, some patients present with bone atrophy adjacent to the plate. However, a comparison of locking and conventional plates as a cause of atrophy has not been reported. The aim of this study was to investigate long-term bone atrophy associated with use of locking and conventional plates for forearm fracture treatment. In this study we included 15 patients with forearm fracture managed by either locking or conventional plates and with more than 5 years of follow-up. Computed tomographic imaging of both forearms was performed to assess bone thickness and local bone mineral density and to predict bone strength without plate reinforcement based on finite element analysis. Mean patient age at surgery was 48.0 years. Eight patients underwent reduction with fixed locking plates and were followed up for a mean of 79.5 months; the remaining 7 patients were treated with conventional plates and were followed up for a mean of 105.0 months. Compared with the conventional plate group, the locking plate group had the same fractured limb-contralateral limb ratio of cortex bone thickness, but had significantly lower ratios of mineral density adjacent to the plate and adjusted bone strength. This study demonstrated bone atrophy after locking plate fixation for forearm fractures. Treatment plans for forearm fracture should take into consideration the impact of bone atrophy long after plate fixation. Therapeutic IV. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  18. Buckling of Flat Thin Plates under Combined Loading

    Directory of Open Access Journals (Sweden)

    Ion DIMA

    2015-03-01

    Full Text Available This article aims to provide a quick methodology to determine the critical values of the forces applied to the central plane of a flat isotropic plate at which a change to the stable configuration of equilibrium occurs. Considering the variety of shapes, boundary conditions and loading combinations, the article does not intend to make an exhaustive presentation of the plate buckling. As an alternative, there will be presented only the most used configurations such as: rectangular flat thin plates, boundary conditions with simply supported (hinged or clamped (fixed edges, combined loadings with single compression or single shear or combination between them, compression and shear, with or without transverse loading, encountered at wings and control surfaces shell of fin and rudder or stabilizer and elevator. The reserve factor and the critical stresses will be calculated using comparatively two methods, namely the methodology proposed by the present article and ASSIST 6.6.2.0 – AIRBUS France software, a dedicated software to local calculations, for a simply supported plate under combined loading, compression on the both sides and shear.

  19. Influence of the apex angle of a hollow prism made from an ordinary commercial glass plate as a simple refractometer to the accuracy of the refractive index measurement of the edible oil

    Science.gov (United States)

    Idris, N.; Maswati; Yusibani, E.

    2018-05-01

    The influence of the apex angle of a hollow prism used as a simple refractometer to the accuracy of a refractive index measurement of the edible oil samples was studied. The hollow prism was made from an ordinary commercial glass plate with a thickness of 2 mm. The apex angle of the constructed hollow prism was varied. The edible oil sample used in this study was palm oil, namely the packaged, branded oil sample and the bulk oil sample. For measuring the refractive index, the oil sample was filled in the constructed hollow prism, and then a helium-neon laser beam was passed through the oil sample at a certain angle of incidence. The angle of minimum deviation of the transmitted laser He-Ne beam was measured and then was used for calculating the refractive index of the oil sample. The refractive index measurement was made using the hollow prism with different apex angles, ranging from 300 to 600. The measurement accuracy was estimated by comparing the refractive index measured using the hollow prisms to that of obtained using a standard Abbe refractometer. It was found that the refractive index of the edible oil can be measured accurately by using the hollow prism. It was also found that the accuracy of the refractive index measurement significantly changes with the apex angle of the hollow prism. The refractive index values measured using this simple refractometer deviate up to 3,49% from the refractive index value measured using the standard Abbe refractometer, especially when the apex angle of the prism is 30°. The measurement results with high accuracies obtained when using the hollow prisms with apex angles of 450 and 600. The optimum apex angle for the present constructed hollow prism is 450. The refractive index obtained using the hollow prism with the apex angle of 450 is 1,4623 and 1,4438 for the bulk oil and the packed, branded oil samples, respectively. This result suggests that the apex angle of the prism used affects largely the accuracy of the

  20. Osteosynthesis of the first phalanx fractures in horses by means of lag screws; Osteosynteza zlaman kosci pecinowej u koni z zastosowaniem srub ciagnacych

    Energy Technology Data Exchange (ETDEWEB)

    Bereznowski, A.; Janicki, A.M.; Sterna, J. [Katedra Chirurgii Zwierzat, Wydzial Weterynarii, SGGW-AR, Warsaw (Poland)

    1996-12-31

    Fractures of the first phalanx belong to the most frequent in horses. Three cases of surgical treatment of first phalanx fractures in horses have been presented. The cases differed by the period of time between the accident and surgical treatment. In all cases osteosynthesis by means of orthopedic screws was applied. In all horses fracture repair was successful, however, not all horses recovered fully enough to return to work. (author). 6 refs, 5 figs.

  1. Distillation, destructive

    Energy Technology Data Exchange (ETDEWEB)

    Brinjes, J F

    1867-03-12

    The invention relates to means for conveying the material through rotary retorts for distilling shale or the like. The retort is fitted with longitudinal ribs which lift the material and allow it to fall again as the retort rotates. Inclined deflecting plates attached to a fixed shaft cause the material as it falls to be gradually fed towards the discharge end of the retort. By means of the handle, which can be fixed in angular position by a pin entering holes in a quadrant, the angle of the plates may be adjusted and the rate of feed may be thus regulated. Or the plates may be hinged on the shaft or to the inside of the retort, and the angle is then adjusted by a longitudinal rod moved by a handwheel and nut. A similar arrangement may be applied to retorts with an oscillating motion.

  2. Effect of matrix cracking and material uncertainty on composite plates

    International Nuclear Information System (INIS)

    Gayathri, P.; Umesh, K.; Ganguli, R.

    2010-01-01

    A laminated composite plate model based on first order shear deformation theory is implemented using the finite element method. Matrix cracks are introduced into the finite element model by considering changes in the A, B and D matrices of composites. The effects of different boundary conditions, laminate types and ply angles on the behavior of composite plates with matrix cracks are studied. Finally, the effect of material property uncertainty, which is important for composite material on the composite plate, is investigated using Monte Carlo simulations. Probabilistic estimates of damage detection reliability in composite plates are made for static and dynamic measurements. It is found that the effect of uncertainty must be considered for accurate damage detection in composite structures. The estimates of variance obtained for observable system properties due to uncertainty can be used for developing more robust damage detection algorithms.

  3. There is no non-zero stable fixed point for dense networks in the homogeneous Kuramoto model

    International Nuclear Information System (INIS)

    Taylor, Richard

    2012-01-01

    This paper is concerned with the existence of multiple stable fixed point solutions of the homogeneous Kuramoto model. We develop a necessary condition for the existence of stable fixed points for the general network Kuramoto model. This condition is applied to show that for sufficiently dense n-node networks, with node degrees at least 0.9395(n−1), the homogeneous (equal frequencies) model has only one stable fixed point solution over the full space of phase angles in the range −π to π. This is the zero fixed point solution defined by all phase angle differences being zero. This result, together with existing research, proves a conjecture of Verwoerd and Mason (2007 Proc. of the American Control Conf. pp 4613–8) that for the complete network and the homogeneous model, the zero fixed point has a basin of attraction consisting of the entire space minus a set of measure zero. The necessary conditions are also tested to see how close to sufficiency they might be by applying them to a class of regular degree networks studied by Wiley et al (2006 Chaos 16 015103). (paper)

  4. Determination of velocity vector angles using the directional cross-correlation method

    DEFF Research Database (Denmark)

    Kortbek, Jacob; Jensen, Jørgen Arendt

    2005-01-01

    and then select the angle with the highest normalized correlation between directional signals. The approach is investigated using Field II simulations and data from the experimental ultrasound scanner RASMUS and with a parabolic flow having a peak velocity of 0.3 m/s. A 7 MHz linear array transducer is used......A method for determining both velocity magnitude and angle in any direction is suggested. The method uses focusing along the velocity direction and cross-correlation for finding the correct velocity magnitude. The angle is found from beamforming directional signals in a number of directions......-time ) between signals to correlate, and a proper choice varies with flow angle and flow velocity. One performance example is given with a fixed value of k tprf for all flow angles. The angle estimation on measured data for flow at 60 ◦ to 90 ◦ , yields a probability of valid estimates between 68% and 98...

  5. Two-phase flow patterns in adiabatic and diabatic corrugated plate gaps

    Science.gov (United States)

    Polzin, A.-E.; Kabelac, S.; de Vries, B.

    2016-09-01

    Correlations for two-phase heat transfer and pressure drop can be improved considerably, when they are adapted to specific flow patterns. As plate heat exchangers find increasing application as evaporators and condensers, there is a need for flow pattern maps for corrugated plate gaps. This contribution presents experimental results on flow pattern investigations for such a plate heat exchanger background, using an adiabatic visualisation setup as well as a diabatic setup. Three characteristic flow patterns were observed in the considered range of two-phase flow: bubbly flow, film flow and slug flow. The occurrence of these flow patterns is a function of mass flux, void fraction, fluid properties and plate geometry. Two different plate geometries having a corrugation angle of 27° and 63°, respectively and two different fluids (water/air and R365mfc liquid/vapor) have been analysed. A flow pattern map using the momentum flux is presented.

  6. Angle-of-arrival-based gesture recognition using ultrasonic multi-frequency signals

    KAUST Repository

    Chen, Hui; Ballal, Tarig; Saad, Mohamed; Al-Naffouri, Tareq Y.

    2017-01-01

    transducer. The 2-D angles of the moving hand are estimated using multi-frequency signals captured by a fixed receiver array. A simple redundant dictionary matching classifier is designed to recognize gestures representing the numbers from `0' to `9

  7. A Passive and Wireless Sensor for Bone Plate Strain Monitoring.

    Science.gov (United States)

    Tan, Yisong; Hu, Jiale; Ren, Limin; Zhu, Jianhua; Yang, Jiaqi; Liu, Di

    2017-11-16

    This paper reports on a sensor for monitoring bone plate strain in real time. The detected bone plate strain could be used for judging the healing state of fractures in patients. The sensor consists of a magnetoelastic material, which can be wirelessly connected and passively embedded. In order to verify the effectiveness of the sensor, a tibia-bone plate-screw (TBS) model was established using the finite element analysis method. A variation of the bone plate strain was obtained via this model. A goat hindquarter tibia was selected as the bone fracture model in the experiment. The tibia was fixed on a high precision load platform and an external force was applied. Bone plate strain variation during the bone fracture healing process was acquired with sensing coils. Simulation results indicated that bone plate strain decreases as the bone gradually heals, which is consistent with the finite element analysis results. This validated the soundness of the sensor reported here. This sensor has wireless connections, no in vivo battery requirement, and long-term embedding. These results can be used not only for clinical practices of bone fracture healing, but also for bone fracture treatment and rehabilitation equipment design.

  8. Flexible fixation and fracture healing

    DEFF Research Database (Denmark)

    Schmal, Hagen; Strohm, Peter C; Jaeger, Martin

    2011-01-01

    , noncomminuted fractures. External fixation uses external bars for stabilization, whereas internal fixation is realized by subcutaneous placement of locking plates. Both of these "biologic" osteosynthesis methods allow a minimally invasive approach and do not compromise fracture hematoma and periosteal blood...

  9. Are diamond-bearing Cretaceous kimberlites related to shallow-angle subduction beneath western North America?

    Science.gov (United States)

    Currie, C. A.; Beaumont, C.

    2009-05-01

    The origin of deep-seated magmatism (in particular, kimberlites and lamproites) within continental plate interiors remains enigmatic in the context of plate tectonic theory. One hypothesis proposes a relationship between kimberlite occurrence and lithospheric subduction, such that a subducting plate releases fluids below a continental craton, triggering melting of the deep lithosphere and magmatism (Sharp, 1974; McCandless, 1999). This study provides a quantitative evaluation of this hypothesis, focusing on the Late Cretaceous- Eocene (105-50 Ma) kimberlites and lamproites of western North America. These magmas were emplaced along a corridor of Archean and Proterozoic lithosphere, 1000-1500 km inboard of the plate margin separating the subducting Farallon Plate and continental North America Plate. Kimberlite-lamproite magmatism coincides with tectonic events, including the Laramide orogeny, shut-down of the Sierra Nevada arc, and eastward migration of volcanism, that are commonly attributed to a change in Farallon Plate geometry to a shallow-angle trajectory (subduction that places the Farallon Plate beneath the western edge of the cratonic interior of North America. This geometry is consistent with the observed continental dynamic subsidence that lead to the development of the Western Interior Seaway. The models also show that the subducting plate has a cool thermal structure, and subducted hydrous minerals (serpentine, phengite and phlogopite) remain stable to more than 1200 km from the trench, where they may break down and release fluids that infiltrate the overlying craton lithosphere. This is supported by geochemical studies that indicate metasomatism of the Colorado Plateau and Wyoming craton mantle lithosphere by an aqueous fluid and/or silicate melt with a subduction signature. Through Cretaceous shallow-angle subduction, the Farallon Plate was in a position to mechanically and chemically interact with North American craton lithosphere at the time of

  10. Optimum tilt angle and orientation for solar collectors in Syria

    International Nuclear Information System (INIS)

    Skeiker, Kamal

    2009-01-01

    One of the important parameters that affect the performance of a solar collector is its tilt angle with the horizon. This is because of the variation of tilt angle changes the amount of solar radiation reaching the collector surface. A mathematical model was used for estimating the solar radiation on a tilted surface, and to determine the optimum tilt angle and orientation (surface azimuth angle) for the solar collector in the main Syrian zones, on a daily basis, as well as for a specific period. The optimum angle was computed by searching for the values for which the radiation on the collector surface is a maximum for a particular day or a specific period. The results reveal that changing the tilt angle 12 times in a year (i.e. using the monthly optimum tilt angle) maintains approximately the total amount of solar radiation near the maximum value that is found by changing the tilt angle daily to its optimum value. This achieves a yearly gain in solar radiation of approximately 30% more than the case of a solar collector fixed on a horizontal surface.

  11. [An adjustable distractor for transverse maxillary distraction osteogenesis].

    Science.gov (United States)

    Leyder, P; Wycisk, G; Quilichini, J

    2013-06-01

    The posterior skeletal widening in conventional distractions (Surgical Assisted Rapid Maxillary Expansion) is often modest, in contrast with a predominant anterior expansion. Until recently, it was not possible to consider transverse palatal distraction osteogenesis and Le Fort I impaction or advancement in the same procedure, as the osteosynthesis plates impeded maxillary anterior opening. We developed new sliding osteosynthesis plates allowing to perform an advancement or impaction Le Fort I osteotomy associated with a low-resistance bipartite palatal distraction osteogenesis. We had for aim to describe the device and to determine its clinical applications. This new palatal distractor is made up of two independent stainless steel jacks allowing for an adjustable distraction in the anterior or posterior area as needed. Bone-borne and tooth-borne versions are available. This new distractor can be adjusted sagittally. The distraction can be angular or parallel, and the distraction mode can be modified during post-operative distraction. This device should be adapted to all clinical presentations. It can be used in combination with sliding osteosynthesis to perform a Le Fort 1 osteotomy and at the same time a complete correction of vertical, horizontal, and sagittal deficiencies. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  12. Mathematical Modeling of Hydroelastic Oscillations of the Stamp and the Plate, Resting on Pasternak Foundation

    Science.gov (United States)

    Mogilevich, L. I.; Popov, V. S.; Popova, A. A.; Christoforova, A. V.

    2018-01-01

    The forced oscillations of the elastic fixed stamp and the plate, resting on Pasternak foundation are studied. The oscillations are caused by pressure pulsation in liquid layer between the stamp and the plate. Pasternak model is chosen as an elastic foundation. The laws of the stamp movement, the plate deflection and pressure in the liquid are discovered on the basis of hydroelasticity problem analytical solution. The functions of amplitude deflection distribution and liquid pressure along the plate are constructed, as well as the stamp amplitude-frequency characteristic. The obtained mathematical model allows to investigate the dynamics of hydroelastic interaction of the stamp with the plate, resting on elastic foundation, to define resonance frequencies of the plate and the stamp and corresponding deflections amplitudes, as well as liquid presser amplitudes.

  13. A radiophotoluminescent glass plate system for medium-sized field dosimetry

    International Nuclear Information System (INIS)

    Nakagawa, Keiichi; Koyanagi, Hiroki; Shiraki, Takashi; Saegusa, Shigeki; Sasaki, Katsutake; Oritate, Takashi; Mima, Kazuo; Miyazawa, Masanori; Ishidoya, Tatsuyo; Ohtomo, Kuni; Yoda, Kiyoshi

    2005-01-01

    A two-dimensional radiophotoluminescent system for medium-sized field dosimetry has been developed using a silver-activated phosphate glass plate with a dimension of 120 mmx120 mmx1 mm and a readout unit comprising a UV excitation lamp and a CCD imager. A dose ranging from 0 to 400 cGy, provided by a 6 MV x-ray beam, was delivered to the glass plate oriented perpendicularly to the beam and positioned in a water phantom at a depth of 10 cm, where the center of the glass plate coincided with the linac isocenter. After the dose delivery, the glass plate was placed in the readout system. The CCD output intensity increased linearly with the applied dose. The angular dependence of response on the direction of radiation incidence was measured by rotating the glass plate in the water phantom, indicating that the output remained constant up to 75 deg. from perpendicular incident direction, followed by a steep reduction down to 85% at an angle of 90 deg. A lateral dose distribution resulting from a 60 mmx60 mm irradiation was compared between the glass plate and an x-ray film having had the same exposure, showing that the glass plate and the x-ray film led to identical dose distributions. The dose reproducibility for a glass plate and the sensitivity variation among different glass plates were also evaluated

  14. Magnetoelastic bending and snapping of ferromagnetic plates in oblique magnetic fields

    International Nuclear Information System (INIS)

    Zhou Youhe

    1995-01-01

    Ferritic stainless steel has been considered for structural components such as first walls and blankets of fusion power reactors because the material shows low rates of irradiation swelling. Since it is magnetizable, the magnetoelastic interaction between magnetic field and deformation of the structures in a fusion reactor is so strong that their safety is of concern due to the magnetoelastic bending, buckling and magnetic damping, etc. Basic research of the magnetoelastic characteristics of ferromagnetic plate has been paid special attention by researchers. In this paper, the magnetoelastic bending and snapping are studied for a ferromagnetic plate in an oblique magnetic field. The theoretical model is based on the variational principle where the functional is employed as real total energy in the system including external work. The obtained expression of magnetic force on the plate is the same as that derived from the dipole model when the total magnetic field in the ferromagnetic medium is considered. In order to effectively solve the nonlinearly coupled interaction problem between magnetic field and mechanical deformation, a numerical program combining the finite element method for analyzing the magnetic field with the finite difference technique for finding out the bending deformation of the plate is employed to obtain the solution of magnetoelastic bending of a soft ferromagnetic plate. The numerical calculations are carried out for the typical example of a ferromagnetic cantilevered beam-plate in an oblique magnetic field. From the bending curves, that is the tip deflection versus applied magnetic fields, the critical magnetic field for the magnetoelastic snapping is predicted by the Southwell plot. The theoretical predictions show that the critical magnetic field decreases with the increase in incident angle of the oblique magnetic field. By the effect of incident angle on the magnetic buckling, the discrepancy between theoretical and experimental data can

  15. Broken symmetries and the Cabibbo angle

    International Nuclear Information System (INIS)

    Lanik, J.

    1975-04-01

    Under the assumption that the SU(3) symmetry is broken down by the strong and electromagnetic interactions, a phenomenological theory of the Cabibbo angle theta is proposed. In this theory the angle theta is fixed, linking together the Cabibbo rotation in the SU(3) space and complete SU(3) breaking consisting of both the SU(3) Hamiltonian and vacuum non-invariances. Assuming that the value of theta is zero in the soft-pion limit and that, in this limit, the only forces responsible for the isotopic symmetry breaking are the usual photonic forces it is shown that the usual electromagnetic interactions can contribute for the value of theta only through the non-vanishing vacuum expectation value of a certain scalar field. Within the framework of the (3,average3)+(3,average3) chiral symmetry-breaking model and through the use of the experimental value of the ratio GAMMA (K→μν)/GAMMA(π→μν), the presented Cabibbo angle theory predicts the value sintheta=0.25 which is in good agreement with experiment. (Lanik, J.)

  16. Inclusive zero-angle neutron spectra at the ISR and OPER-model

    International Nuclear Information System (INIS)

    Grigoryan, A.A.

    1977-01-01

    The invlusive zero-angle neutron spectra in pp-collisions measured at the ISR are compared with the OPER-model predictions. OPER-model rather well describes the experimental data. Some features of the spectra behaviour at fixed transverse momentum and large x are considered

  17. Repair and Strengthening by Use of Superficial Fixed Laminates of Cracked Masonry Walls Sheared Horizontally-Laboratory Tests

    International Nuclear Information System (INIS)

    Kubica, Jan; Kwiecien, Arkadiusz; Zajac, Boguslaw

    2008-01-01

    There are many methods of crack repairing in masonry structures. One of them is repair and strengthening by using of superficial fixed laminates, especially in case of masonry walls with plastering on their both sides. The initial laboratory tests of three different types of strengthening of diagonal cracked masonry wallettes are presented. Tests concerned three clay brick masonry walls subjected to horizontal shearing with two levels of precompression and strengthened by flexible polymer injection, superficial glass fixed by polymer fibre laminate plates and using of CRFP strips stiff fixed to the wall surface by polymer and stiff resin epoxy fixing are presented and discussed

  18. Elasto-plastic deformation and plate weakening due to normal faulting in the subducting plate along the Mariana Trench

    Science.gov (United States)

    Zhou, Zhiyuan; Lin, Jian

    2018-06-01

    We investigated variations in the elasto-plastic deformation of the subducting plate along the Mariana Trench through an analysis of flexural bending and normal fault characteristics together with geodynamic modeling. Most normal faults were initiated at the outer-rise region and grew toward the trench axis with strikes mostly subparallel to the local trench axis. The average trench relief and maximum fault throws were measured to be significantly greater in the southern region (5 km and 320 m, respectively) than the northern and central regions (2 km and 200 m). The subducting plate was modeled as an elasto-plastic slab subjected to tectonic loading at the trench axis. The calculated strain rates and velocities revealed an array of normal fault-like shear zones in the upper plate, resulting in significant faulting-induced reduction in the deviatoric stresses. We then inverted for solutions that best fit the observed flexural bending and normal faulting characteristics, revealing normal fault penetration to depths of 21, 20, and 32 km beneath the seafloor for the northern, central, and southern regions, respectively, which is consistent with the observed depths of the relocated normal faulting earthquakes in the central Mariana Trench. The calculated deeper normal faults of the southern region might lead to about twice as much water being carried into the mantle per unit trench length than the northern and central regions. We further calculated that normal faulting has reduced the effective elastic plate thickness Te by up to 52% locally in the southern region and 33% in both the northern and central regions. The best-fitting solutions revealed a greater apparent angle of the pulling force in the southern region (51-64°) than in the northern (22-35°) and central (20-34°) regions, which correlates with a general southward increase in the seismically-determined dip angle of the subducting slab along the Mariana Trench.

  19. Walk-off reduction, using an external optical plate and Bessel–Gaussian interaction

    International Nuclear Information System (INIS)

    Mansouri, Masoume; Askarbioki, Mohsen; Ghavami Sabouri, Saeed; Khorsandi, Alireza

    2015-01-01

    To reduce the walk-off angle of the extraordinary third-harmonic ultraviolet wave at 355 nm generated by type II KTiOPO 4 and type I β-BaB 2 O 4 optical crystals, and the Gaussian output beam of a Q-switched Nd:YAG laser, a simple theoretical model was developed based on a rotatable BK7 plate of variable thickness. By rotating the plate up to 35° along the beam direction, we reduced the walk-off angle up to ∼ 13%. The same phenomenon is predicted by the model, confirming the performance of the model. It is found that, due to the walk-off effect, the intensity profile of the third-harmonic generation beam is slightly degraded. To compensate for the observed phenomena and further reduce the walk-off, we used a combination of a convex lens and an axicon to transform the beam profile of the interacting fundamental and second-harmonic generation waves to the zero-order Bessel–Gaussian form. As a result, the walk-off is decreased to ∼48.81 mrad, providing ∼30% relative reduction. By using the same BK7 plate rotated up to 35° along the third-harmonic beam direction, the walk-off angle is further reduced to 38.9 mrad. Moreover, it is observed that the beam profile of the emerged Bessel–Gaussian third-harmonic generation beam remains unchanged with no degradation. (paper)

  20. Walk-off reduction, using an external optical plate and Bessel-Gaussian interaction

    Science.gov (United States)

    Masoume, Mansouri; Mohsen, Askarbioki; Saeed Ghavami, Sabouri; Alireza, Khorsandi

    2015-02-01

    To reduce the walk-off angle of the extraordinary third-harmonic ultraviolet wave at 355 nm generated by type II KTiOPO4 and type I β-BaB2O4 optical crystals, and the Gaussian output beam of a Q-switched Nd:YAG laser, a simple theoretical model was developed based on a rotatable BK7 plate of variable thickness. By rotating the plate up to 35° along the beam direction, we reduced the walk-off angle up to ˜ 13%. The same phenomenon is predicted by the model, confirming the performance of the model. It is found that, due to the walk-off effect, the intensity profile of the third-harmonic generation beam is slightly degraded. To compensate for the observed phenomena and further reduce the walk-off, we used a combination of a convex lens and an axicon to transform the beam profile of the interacting fundamental and second-harmonic generation waves to the zero-order Bessel-Gaussian form. As a result, the walk-off is decreased to ˜48.81 mrad, providing ˜30% relative reduction. By using the same BK7 plate rotated up to 35° along the third-harmonic beam direction, the walk-off angle is further reduced to 38.9 mrad. Moreover, it is observed that the beam profile of the emerged Bessel-Gaussian third-harmonic generation beam remains unchanged with no degradation.

  1. Translocación del tercio medio facial en un paciente en edad infantil: Fijación con un nuevo sistema de placas y pines reabsorbibles Mid-facial translocation in children using a new system of absorbable plates and pins: A case report

    Directory of Open Access Journals (Sweden)

    Manel Coll-Anglada

    2010-12-01

    Full Text Available La translocación del tercio medio facial, técnica consistente en la movilización del esqueleto centrofacial pediculado a los tejidos blandos, ha demostrado permitir un amplio acceso para el abordaje de lesiones situadas en las regiones faciales profundas y la región central de la base del cráneo. Uno de los principales inconvenientes que presentaba este abordaje en niños era la fijación del esqueleto con placas y tornillos de titanio, ya que podía interferir en el crecimiento del hueso en desarrollo. Todo ello planteaba el problema de una segunda intervención para la retirada del material, aumentando, de forma significativa, la morbilidad del procedimiento. Como solución al problema se comercializa, a partir de la década de 1980, el material de osteosíntesis reabsorbible. Presentamos a una paciente de 13 años de edad diagnosticada de un cordoma localizado en el clivus. Como abordaje, se realiza una translocación bilateral del tercio medio facial y se utiliza, para la fijación del esqueleto facial, un nuevo sistema de placas y tornillos reabsorbibles basado en ultrasonidos (Sonic Weld®. KLS Martin, LP, Jacksonville, Florida, USA. Se describen los principales abordajes a las regiones faciales profundas y centromediales de la base del cráneo, las principales variantes de la translocación del tercio medio facial, la técnica de aplicación del nuevo sistema Sonic Weld® y sus diferencias principales respecto a los sistemas reabsorbibles tradicionales.Mid-facial translocation, which involves mobilization of the central facial skeletal structures together with soft tissue pedicles, provides generous access to the anterior and central regions of the skull base. One of the drawbacks of this approach in children is skeletal fixation with titanium osteosynthesis plates and screws, which may affect the growth of developing bone. Consequently, a second intervention is required to remove titanium osteosynthesis material, which increases the

  2. Underwater Shock Response of Circular HSLA Steel Plates

    Directory of Open Access Journals (Sweden)

    R. Rajendran

    2000-01-01

    Full Text Available Studies on shock response of circular plates subjected to underwater explosion is of interest to ship designers. Non-contact underwater explosion experiments were carried out on air backed circular High Strength Low Alloy (HSLA steel plates of 4 mm thickness and 290 mm diameter. The experiments were carried out in two phases. In the first phase, strain gauges were fixed at intervals of 30 mm from the centre of the plate and strains were recorded for the shock intensity gradually increasing to yielding. Semi-analytical models were derived for the elastic strain prediction which showed good agreement with the experiments. Dynamic yield stress and the shock factor for yielding were established. In the second phase, individual plates were subjected to increasing shock severity until fracture and the apex bulge depth and the thickness strains were measured. Empirical models were derived to predict the plastic deformation which were validated through a fresh set of experiments. Analysis of the fractured surface by visual examination showed that there was slant fracture indicating ductile mode of failure and the same was corroborated by Scanning Electron Microscopic (SEM examination.

  3. Soft tissue thin-plate spline analysis of pre-pubertal Korean and European-Americans with untreated Angle's Class III malocclusions.

    Science.gov (United States)

    Singh, G D; McNamara, J A; Lozanoff, S

    1999-01-01

    The purpose of this study was to assess soft tissue facial matrices in subjects of diverse ethnic origins with underlying dentoskeletal malocclusions. Pre-treatment lateral cephalographs of 71 Korean and 70 European-American children aged between 5 and 11 years with Angle's Class III malocclusions were traced, and 12 homologous, soft tissue landmarks digitized. Comparing mean Korean and European-American Class III soft tissue profiles, Procrustes analysis established statistical difference (P thin-plate spline analysis indicated that both affine and non-affine transformations contribute towards the total spline (deformation) of the averaged Class III soft tissue configurations. For non-affine transformations, partial warp (PW) 8 had the highest magnitude, indicating large-scale deformations visualized as labio-mental protrusion, predominantly. In addition, PW9, PW4, and PW5 also had high magnitudes, demonstrating labio-mental vertical compression and antero-posterior compression of the lower labio-mental soft tissues. Thus, Korean children with Class III malocclusions demonstrate antero-posterior and vertical deformations of the labio-mental soft tissue complex with respect to their European-American counterparts. Morphological heterogeneity of the soft tissue integument in subjects of diverse ethnic origin may obscure the underlying skeletal morphology, but the soft tissue integument appears to have minimal ontogenetic association with Class III malocclusions.

  4. Value of the lumbar lordotic angle taken from CT scanogram as an index of back pain

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Hea Sang; Kim, Guk Hee; Kim, Dae Young [Kangnam General Hospital Public Corporation, Seoul (Korea, Republic of)

    1986-10-15

    'Normal' spinal posture is generally accepted as moderate lordosis of the cervical and the lumbar sections of spine and moderate kyphosis of the thoracic and sacrococcygeal sections. Among these normal range of the lumbar lordosis is less well defined. CT is very useful method to identified the bony structure and adjacent soft tissue of the spine, so it is very available method to detect accurate lumbar lordotic angle by using lateral Scanogram. Analysis and comparison of lumbar lordotic angles, crossing angle are drawn each parallel line to the superior end plate of body of 1st. lumbar vertebra and to the inferior end plate of the 5th. lumbar vertebra, in 174 cases with backache and 50 cases normal groups at Kangnam General Hospital Public Corporation, from Aug. 1985 to Jul 1986. Male and female were almostly same affected in backache group (1.1:1). And most lumbar lordotic angles were 10 to 40 between all backache age group. On backache group, over all mean lumbar lordotic angles were 24.7+-8.9 but no significant difference at mean value of the each diseases, such as HIVD, Degenerative Spondylosis or No Remarkable Findings group. On control group, over all mean ones were 29.2+-8.0. So, significant difference of lumbar lordotic angle between backache and control group, and most difference is at 5th. decade group (p 0.01).

  5. Wear plates control rod guide tubes top internal reactor vessel C. N. VANDELLOS II

    International Nuclear Information System (INIS)

    2010-01-01

    The guide tubes for control rods forming part of the upper internals of the reactor vessel, its function is to guide the control rod to permit its insertion in the reactor core. These guide tubes are suspended from the upper support plate which are fixed by bolts and extending to the upper core plate which is fastened by clamping bolts (split pin) to prevent lateral displacement of the guide tubes, while allowing axial expansion.

  6. Contact angle adjustment in equation-of-state-based pseudopotential model.

    Science.gov (United States)

    Hu, Anjie; Li, Longjian; Uddin, Rizwan; Liu, Dong

    2016-05-01

    The single component pseudopotential lattice Boltzmann model has been widely applied in multiphase simulation due to its simplicity and stability. In many studies, it has been claimed that this model can be stable for density ratios larger than 1000. However, the application of the model is still limited to small density ratios when the contact angle is considered. The reason is that the original contact angle adjustment method influences the stability of the model. Moreover, simulation results in the present work show that, by applying the original contact angle adjustment method, the density distribution near the wall is artificially changed, and the contact angle is dependent on the surface tension. Hence, it is very inconvenient to apply this method with a fixed contact angle, and the accuracy of the model cannot be guaranteed. To solve these problems, a contact angle adjustment method based on the geometry analysis is proposed and numerically compared with the original method. Simulation results show that, with our contact angle adjustment method, the stability of the model is highly improved when the density ratio is relatively large, and it is independent of the surface tension.

  7. Investigation of Blade Angle of an Open Cross-Flow Runner

    Science.gov (United States)

    Katayama, Yusuke; Iio, Shouichiro; Veerapun, Salisa; Uchiyama, Tomomi

    2015-04-01

    The aim of this study was to develop a nano-hydraulic turbine utilizing drop structure in irrigation channels or industrial waterways. This study was focused on an open-type cross-flow turbine without any attached equipment for cost reduction and easy maintenance. In this study, the authors used an artificial indoor waterfall as lab model. Test runner which is a simple structure of 20 circular arc-shaped blades sandwiched by two circular plates was used The optimum inlet blade angle and the relationship between the power performance and the flow rate approaching theoretically and experimentally were investigated. As a result, the optimum inlet blade angle due to the flow rate was changed. Additionally, allocation rate of power output in 1st stage and 2nd stage is changed by the blade inlet angle.

  8. Treatment of periprosthetic femoral fractures of the knee.

    Science.gov (United States)

    Ehlinger, Matthieu; Adam, Philippe; Abane, Lamine; Rahme, Michel; Moor, Beat Kaspar; Arlettaz, Yvan; Bonnomet, François

    2011-09-01

    We report a continuous series of periprosthetic femoral fractures after knee arthroplasty treated with a locking plate. We hypothesize that minimally invasive surgery and immediate weight-bearing improve functional recovery. From June 2002 to December 2008, 15 patients with 16 fractures were treated. Median age was 81 years. The autonomy level according to the mobility score of Parker and Palmer showed a median of 5 (0-9). Osteosynthesis was performed mainly through a minimally invasive approach using a locking compression plate. The rehabilitation protocol consisted of immediate mobilization and, whenever possible, immediate unrestricted weight-bearing. Five patients died during follow-up, more than 1 year after osteosynthesis. Their results were included. Autonomy and mobility were preserved with a median postoperative score of 4 (0-9) according to Parker and Palmer. The consolidation rate was 93.8%, which was obtained within 10 weeks. There were no mechanical or infectious complications. Fourteen cases were treated with minimally invasive surgery without fracture exposition; the remaining 2 required a slightly more extended approach. Full weight-bearing occurred 10 times; 20-kg partial weight-bearing was advised twice; and on 4 occasions, no weight-bearing was allowed for 6 weeks. Osteosynthesis with a minimally invasive bridge-plating technique is effective in the treatment of periprosthetic, distal femoral fractures without component loosening. Immediate full weight-bearing is possible if certain rules are respected. The surgical management presented herein is beneficial for these challenging fractures, and it may help reduce the complication rate and improve functional outcome.

  9. The role of frictional strength on plate coupling at the subduction interface

    KAUST Repository

    Tan, Eh; Lavier, Luc L.; Van Avendonk, Harm J. A.; Heuret, Arnauld

    2012-01-01

    and serpentinized mantle (friction angle 1 to 15, or static friction coefficient 0.017 to 0.27) to control the amount of frictional coupling between the plates. With plastic strain weakening in the lithosphere, our numerical models can attain stable subduction

  10. 3D printing utility for surgical treatment of acetabular fractures.

    Science.gov (United States)

    Chana Rodríguez, F; Pérez Mañanes, R; Narbona Cárceles, F J; Gil Martínez, P

    2018-05-25

    Preoperative 3D modelling enables more effective diagnosis and simulates the surgical procedure. We report twenty cases of acetabular fractures with preoperative planning performed by pre-contouring synthesis plates on a 3D printed mould obtained from a computarized tomography (CT) scan. The mould impression was made with the DaVinci 1.0 printer model (XYZ Printing). After obtaining the printed hemipelvis, we proceeded to select the implant size (pelvic Matta system, Stryker ® ) that matched the characteristics of the fracture and the approach to be used. Printing the moulds took a mean of 385minutes (322-539), and 238grams of plastic were used to print the model (180-410). In all cases, anatomic reduction was obtained and intra-operative changes were not required in the initial contouring of the plates. The time needed to perform the full osteosynthesis, once the fracture had been reduced was 16.9minutes (10-24). In one case fixed with two plates, a postoperative CT scan showed partial contact of the implant with the surface of the quadrilateral plate. In the remaining cases, the contact was complete. In conclusion, our results suggest that the use of preoperative planning, by printing 3D mirror imaging models of the opposite hemipelvis and pre-contouring plates over the mould, might effectively achieve a predefined surgical objective and reduce the inherent risks in these difficult procedures. Copyright © 2018. Publicado por Elsevier España, S.L.U.

  11. Bolt and nut evaluator

    Science.gov (United States)

    Kerley, James J.; Burkhardt, Raymond; White, Steven

    1994-02-01

    A device for testing fasteners such as nuts and bolts is described which consists of a fixed base plate having a number of threaded and unthreaded holes of varying size for receiving the fasteners to be tested, a torque marking paper taped on top the fixed base plate for marking torque-angle indicia, a torque wrench for applying torque to the fasteners being tested, and an indicator for showing the torque applied to the fastener. These elements provide a low cost, nondestructive device for verifying the strength of bolts and nuts.

  12. Locking device of a guiding ring on a plate including an aperture; application to guide tube of nuclear reactor

    International Nuclear Information System (INIS)

    Cauquelin, C.; Poitrenaud, P.

    1987-01-01

    To make easy to take to pieces a guide tube, by a simple tool, this device includes a guide ring. This guide ring aligned with an aperture in a plate has a tubular support fixed to the plate and coaxial with the aperture and lock the guide tube by rotation [fr

  13. The influence of finite cavities on the sound insulation of double-plate structures.

    Science.gov (United States)

    Brunskog, Jonas

    2005-06-01

    Lightweight walls are often designed as frameworks of studs with plates on each side--a double-plate structure. The studs constitute boundaries for the cavities, thereby both affecting the sound transmission directly by short-circuiting the plates, and indirectly by disturbing the sound field between the plates. The paper presents a deterministic prediction model for airborne sound insulation including both effects of the studs. A spatial transform technique is used, taking advantage of the periodicity. The acoustic field inside the cavities is expanded by means of cosine-series. The transmission coefficient (angle-dependent and diffuse) and transmission loss are studied. Numerical examples are presented and comparisons with measurement are performed. The result indicates that a reasonably good agreement between theory and measurement can be achieved.

  14. Drawing plan for solid works

    International Nuclear Information System (INIS)

    Lee, Kuk Hwan; Kim, Hyung Seop; Yu, Dae Won

    2004-02-01

    This book deals with beginning solid works 2003, setting system option, setting tool group, setting document and storing part template file. It also introduces works of basic solid works modeling such as making of square, circuit, plate washer, square column, block I, block II, link, cover plate, position block and housing. The last part explains drawing of fix block, stopper plate III, bracket, cover, belt pulley, circle plate, square, block, stopper block, angle block, washer, circle block and link.878

  15. Parametric Study of the Device Angle Dependency of a Single Vortex Generator on a Flat Plate

    DEFF Research Database (Denmark)

    Fernandez, U.; Réthoré, Pierre-Elouan; Sørensen, Niels N.

    A detailed study of the device angle dependency of a single vortex generator (VG) is presented in this paper. A single Vortex Generator on a test section wall case, with four different positions of the device angle to the incoming flow, has been designed and solved by computational methods...

  16. Treating natural disaster victims is dealing with shortages: An orthopaedics perspective.

    NARCIS (Netherlands)

    Dewo, Punto; Magetsari, Rahadyan; Busscher, Henk J.; van Horn, Jim R.; Verkerke, Gijsbertus Jacob

    2008-01-01

    During natural disasters such as earthquakes or tsunamis, most of the casualties are known to suffer from musculoskeletal injuries. This leads to an enormous need of orthopaedic (surgical) implants such as osteosynthesis plates, which are difficult to provide in developing countries that rely on

  17. Ag-polytetrafluoroethylene composite coating on stainless steel as bipolar plate of proton exchange membrane fuel cell

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Yu. [Laboratory of Fuel Cells, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Zhongshan Road, Dalian 116023 (China); Graduate University of Chinese Academy of Sciences, Beijing 100049 (China); Hou, Ming; Shao, Zhigang; Yi, Baolian [Laboratory of Fuel Cells, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Zhongshan Road, Dalian 116023 (China); Xu, Hongfeng; Hou, Zhongjun; Ming, Pingwen [Sunrise Power Co., Ltd., Dalian 116025 (China)

    2008-08-01

    Forming a coating on metals by surface treatment is a good way to get high performance bipolar plate of proton exchange membrane fuel cell (PEMFC). In our research, Ag-polytetrafluoroethylene (PTFE) composite film was electrodeposited with silver-gilt solution of nicotinic acid by a bi-pulse electroplating power supply on 316 L stainless steel bipolar plate of PEMFC. Surface topography, contact angle, interfacial conductivity and corrosion resistance of the bipolar plate samples were investigated. Results showed that the defects on the Ag-PTFE composite coating are greatly reduced compared with those on the pure Ag coating fabricated under the same condition; and the contact angle of the Ag-PTFE composite coating with water is 114 , which is much bigger than that of the pure Ag coating (73 ). In addition, the interfacial contact resistance of the composite coating stays as low as the pure Ag coating; and the bipolar plate sample with composite coating shows a close corrosion resistance to the pure Ag coating sample in potentiodynamic and potentiostatic tests. Coated 316 L stainless steel plate with Ag-PTFE composite coating exhibits well hydrophobic characteristic, less defects, high interfacial conductivity and good corrosion resistance, which shows a great potential of the application in PEMFC. (author)

  18. Osteossíntese de fratura diafisária do úmero com placa em ponte: apresentação e descrição da técnica Osteosynthesis of the humeral shaft fractures, with bridge plate

    Directory of Open Access Journals (Sweden)

    Bruno Livani

    2004-06-01

    Full Text Available Os autores descrevem o método cirúrgico inédito para o tratamento das fraturas da diáfise do úmero, com placa colocada por técnica minimamente invasiva. Após estudos anatômicos, foram identificadas três acessos cirúrgicos pelos quais se pode introduzir uma placa na face anterior do úmero, sem risco de lesão vásculo nervosa. O acesso proximal se faz entre os múculos deltóide, lateralmente, e bíceps braquial, medialmente. Nas fraturas do terço médio o acesso distal é feito entre os músculos bíceps braquial e braquial com a placa introduzida de proximal para distal. Nas fraturas distais do úmero o acesso proximal é o mesmo, mas o acesso distal é o descrito por Kocher, com a placa introduzida de distal para proximal e fixada na face anterior da coluna lateral do úmero. O método aqui apresentado vem sendo utilizado desde junho de 2001, principalmente nos pacientes politraumatizados e polifraturados, por ser rápida, segura e por permitir que o paciente possa ser operado em decúbito dorsal horizontal. Além disso, não há necessidade de intensificador de imagem, ou mesmo aparelho de radiografia. Até o momento não foram observadas complicações vásculo nervosas nos 22 pacientes tratados.The authors describe for the first time ever a minimally invasive plate osteosythesis for the treatment of the humeral shatf fractures. After anatomic human cadaver's studies, it was identified three surgical approaches for plate percutaneous insertion on the anterior surface of the humerus without vascular and nervous injury. The proximal approach is between the biceps and deltoid muscles. The distal approach for medial third fractures is between the biceps brachialis and brachialis muscles. The plate is inserted from the proximal to distal direction. For distal fractures, the proximal approach is the same described by Krocher, with the plate inserted from distal to proximal and fixed on the anterior surface of the lateral column of the

  19. Microscopic Holography for flow over rough plate

    Science.gov (United States)

    Talapatra, Siddharth; Hong, Jiarong; Lu, Yuan; Katz, Joseph

    2008-11-01

    Our objective is to measure the near wall flow structures in a turbulent channel flow over a rough wall. In-line microscopic holographic PIV can resolve the 3-D flow field in a small sample volume, but recording holograms through a rough surface is a challenge. To solve this problem, we match the refractive indices of the fluid with that of the wall. Proof of concept tests involve an acrylic plate containing uniformly distributed, closely packed 0.45mm high pyramids with slope angle of 22^^o located within a concentrated sodium iodide solution. Holograms recorded by a 4864 x 3248 pixel digital camera at 10X magnification provide a field of view of 3.47mm x 2.32mm and pixel resolution of 0.714 μm. Due to index matching, reconstructed seed particles can be clearly seen over the entire volume, with only faint traces with the rough wall that can be removed. Planned experiments will be performed in a 20 x 5 cm rectangular channel with the top and bottom plates having the same roughness as the sample plate.

  20. The clinical application of absorbable intramedullary nail and claw plate on treating multiple rib fractures.

    Science.gov (United States)

    Chai, X; Lin, Q; Ruan, Z; Zheng, J; Zhou, J; Zhang, J

    2013-08-01

    The absorption intramedullary nail and claw plate indications and efficacy were investigated in the treatment of a life-threatening multiple rib fractures. A retrospective analysis of 248 surgically treated rib fracture patients was performed who admitted to our hospital from March 2007 to December 2012. Intramedullary nailing was performed in 28 cases, a claw-type bone plate was fixed in 141 cases, and a combination of both was fixed in 79 cases. All internal fixation patients were clinically cured except 1 patient died 14 days after a massive pulmonary embolism. The patients with flail chest and floating chest wall causing respiratory and circulatory disorders were promptly corrected. Routine follow-up was from 1 to 2 years, displaced fractures were in 2 cases, and there were 11 cases of internal fixation and extraction. Internal fixation is a simple and reliable method for the treatment of multiple rib fractures. Both internal fixation materials have their pros and cons but the claw bone plate is more robust. The actual selection of appropriate treatment options helps to improve the treatment efficacy.

  1. Numerical Study on the Effect of Distribution Plates in the Manifolds on the Flow Distribution and Thermal Performance of a Flat Plate Solar Collector

    Directory of Open Access Journals (Sweden)

    Juan Manuel García-Guendulain

    2018-04-01

    Full Text Available Flow maldistribution represents a problem of particular interest in the engineering field for several thermal systems. In flat plate solar collectors, the thermal efficiency strongly depends on the flow distribution through the riser tubes, where a uniform distribution causes a uniform temperature distribution and therefore a higher efficiency. In this work, a Computational Fluid Dynamics (CFD numerical analysis has been carried out using the commercial software FLUENT®, in order to determine the flow distribution, pressure drop and hence the thermal efficiency of a solar collector with distribution flow plates inside the manifolds. The obtained numerical solution for this type of thermal systems has been validated with experimental results available in literature for laminar and turbulent flow. Four distribution plate configurations were analyzed. Results show that using two distribution plates in each of both manifolds improves the flow uniformity up to 40% under the same operating conditions when distribution plates are not used. Besides, it is shown that there exists an increase in the overall pressure drop which is practically negligible for the tilt angles commonly employed in the installation of flat plate solar collectors in Mexico. The use of closed end distribution plates on the dividing and combining manifolds allows the thermal efficiency to become close to the ideal thermal efficiency which is obtained with a uniform flow distribution.

  2. Process and device for removing sludge deposited on the tube plate of a steam generator

    International Nuclear Information System (INIS)

    Charamathieu, A.; Dessales, J.; Lebouc, B.

    1983-01-01

    To remove the sludges on the tubular plate, one lance, at least, is moved radially from the center of the tubular plate between two rows of tubes, in a parallel direction to the tubular plate and near this one. Two high pressure jets are moved from the extremity of the lance and, in fixed and symmetrical directions about the direction of the rows. The two jets are interrupted when passing in front of the heat exchange tubes of the generator; the cleaning liquid is simultaneously carried off from the periphery of the group of tubes [fr

  3. Research on Geometric Positioning Algorithm of License Plate in Multidimensional Parameter Space

    Directory of Open Access Journals (Sweden)

    Yinhua Huan

    2014-05-01

    Full Text Available Considering features of vehicle license plate location method which commonly used, in order to search a consistent location for reference images with license plates feature in multidimensional parameter space, a new algorithm of geometric location is proposed. Geometric location algorithm main include model training and real time search. Which not only adapt the gray-scale linearity and the gray non-linear changes, but also support changes of scale and angle. Compared with the mainstream locating software, numerical results shows under the same test conditions that the position deviation of geometric positioning algorithm is less than 0.5 pixel. Without taking into account the multidimensional parameter space, Geometric positioning algorithm position deviation is less than 1.0 pixel and angle deviation is less than 1.0 degree taking into account the multidimensional parameter space. This algorithm is robust, simple, practical and is better than the traditional method.

  4. A study on the load distribution factor in the perforated square plate with elastic support

    International Nuclear Information System (INIS)

    Lee, Y.S.; Yim, J.S.

    1993-01-01

    The load distribution factor in the perforated square plate supporting by angle shape legs under concentrated load acting at arbitrary points through elastic media is calculated. For the calculation the perforated plate was converted into an orthotropic plate using the method suggested by J.B. Mahoney. The deflection for the calculation of the load distribution factor was obtained from the auxiliary plate which was extended both sides of the plate and it was compared with the results from ANSYS calculation. With this deflection, the calculation of the load distribution factor was performed. The result shows that the load distribution factor at the periphery of the plate is larger than that of in the central location. This load distribution factor could be used for re-distribution of the applied load in more accurate analysis of the plate as well as in the analysis of the elastic media as the load factor. (author)

  5. Modeling of damage evaluation in thin composite plate loaded by pressure loading

    Directory of Open Access Journals (Sweden)

    Dudinský M.

    2012-12-01

    Full Text Available This article presents the results of numerical analysis of elastic damage of thin laminated long fiber-reinforced composite plate consisting of unidirectional layers which is loaded by uniformly distributed pressure. The analysis has been performed by means of the finite element method (FEM. The numerical implementation uses layered plate finite elements based on the Kirchhoff plate theory. System of nonlinear equations has been solved by means of the Newton- Raphson procedure. Evolution of damage has been solved using the return-mapping algorithm based on the continuum damage mechanics (CDM. The analysis was performed using own program created in MATLAB. Problem of laminated fiber-reinforced composite plate fixed on edges for two different materials and three different laminate stacking sequences (LSS was simulated. Evolution of stresses vs. strains and also evolution of damage variables in critical points of the structure are shown.

  6. Numerical Study of Thermal and Flow Characteristics of Plate-Fin Heat Sink with Longitudinal Vortex Generator Installed on the Ground

    Directory of Open Access Journals (Sweden)

    Yen-Tso Chang

    2014-01-01

    Full Text Available This study applied the commercial software ANSYS CFD (FLUENT, for simulating the transient flow field and investigating the influence of each parameter of longitudinal vortex generators (LVGs on the thermal flux of a plate-fin heat sink. Vortex generator was set in front of plate-fin heat sink and under the channel, which was in common-flow-down (CFD and common-flow-up (CFU conditions, which have the result of vortex generator of delta winglet pair (DWP. In this study the parameters were varied, such as the minimum transverse distance between winglet pair, the attack angle of the vortex generator, fins number, the fin height, and the distance between the vortex generator and plate-fin. The coolant fluid flew into the fin-to-fin channel and pushed the vortex from different geometry toward the bottom. This phenomenon took off the heat from the plate to enhance the heat transfer. The numerical results indicated that the LVGs located close to the plate-fin heat sink are zero with the attack angle being 30°, presenting optimal overall conditions.

  7. Value of the lumbar lordotic angle taken from CT scanogram as an index of back pain

    International Nuclear Information System (INIS)

    Jeon, Hea Sang; Kim, Guk Hee; Kim, Dae Young

    1986-01-01

    'Normal' spinal posture is generally accepted as moderate lordosis of the cervical and the lumbar sections of spine and moderate kyphosis of the thoracic and sacrococcygeal sections. Among these normal range of the lumbar lordosis is less well defined. CT is very useful method to identified the bony structure and adjacent soft tissue of the spine, so it is very available method to detect accurate lumbar lordotic angle by using lateral Scanogram. Analysis and comparison of lumbar lordotic angles, crossing angle are drawn each parallel line to the superior end plate of body of 1st. lumbar vertebra and to the inferior end plate of the 5th. lumbar vertebra, in 174 cases with backache and 50 cases normal groups at Kangnam General Hospital Public Corporation, from Aug. 1985 to Jul 1986. Male and female were almostly same affected in backache group (1.1:1). And most lumbar lordotic angles were 10 to 40 between all backache age group. On backache group, over all mean lumbar lordotic angles were 24.7±8.9 but no significant difference at mean value of the each diseases, such as HIVD, Degenerative Spondylosis or No Remarkable Findings group. On control group, over all mean ones were 29.2±8.0. So, significant difference of lumbar lordotic angle between backache and control group, and most difference is at 5th. decade group (p 0.01).

  8. Value of the lumbar lordotic angle taken from CT scanogram as an index of back pain

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Hea Sang; Kim, Guk Hee; Kim, Dae Young [Kangnam General Hospital Public Corporation, Seoul (Korea, Republic of)

    1986-10-15

    'Normal' spinal posture is generally accepted as moderate lordosis of the cervical and the lumbar sections of spine and moderate kyphosis of the thoracic and sacrococcygeal sections. Among these normal range of the lumbar lordosis is less well defined. CT is very useful method to identified the bony structure and adjacent soft tissue of the spine, so it is very available method to detect accurate lumbar lordotic angle by using lateral Scanogram. Analysis and comparison of lumbar lordotic angles, crossing angle are drawn each parallel line to the superior end plate of body of 1st. lumbar vertebra and to the inferior end plate of the 5th. lumbar vertebra, in 174 cases with backache and 50 cases normal groups at Kangnam General Hospital Public Corporation, from Aug. 1985 to Jul 1986. Male and female were almostly same affected in backache group (1.1:1). And most lumbar lordotic angles were 10 to 40 between all backache age group. On backache group, over all mean lumbar lordotic angles were 24.7+-8.9 but no significant difference at mean value of the each diseases, such as HIVD, Degenerative Spondylosis or No Remarkable Findings group. On control group, over all mean ones were 29.2+-8.0. So, significant difference of lumbar lordotic angle between backache and control group, and most difference is at 5th. decade group (p 0.01).

  9. Mandibular osteosynthesis in a Boa constrictor snake

    Directory of Open Access Journals (Sweden)

    Jorge Luiz Costa Castro

    2014-02-01

    Full Text Available Nowadays are observed an increase in the finding of certain wild animals in urban areas, due to environmental changes caused by deforestation and economic use of natural areas. It causes disappearance of usual prey and forces these animals, including snakes, to migrate to urban areas, becoming vulnerable to injuries caused by aggressions, car accidents and capture. Mandibular and maxillar fractures are common in many animal species, representing about 3-6% of all bone fractures in dogs and cats. Mandibular trauma usually occurs as a result of fights, car accidents and improper handling and/or restraint, and fractures can be closed or open, clean or contaminated. The jaw is a flat bone with differences from the long bones that should be taken into consideration for successful treatment, being minimal muscle coverage and need to maintain occlusion factors that influence the definition of the best ostheosynthesis method. The methods of stabilization include using intramedullary pins, wires, external skeletal fixation, bone plate, and acrylic resin. Conventional bone plates are efficient but related to some complications, such as the necessity of muscular elevation and high risk of injuries to mandibular structures. This article describes the successful results of the application of plate and screws in the ostheosynthesis of a mandibular fracture in a female Boa constrictor snake with weight of 8.0 kg and length of 1.80 m, at the RIOZOO Foundation (Rio de Janeiro, RJ, Brazil.

  10. Free vibration analysis of perforated plate with square penetration pattern using equivalent material properties

    Energy Technology Data Exchange (ETDEWEB)

    Jhung, Myung Ho [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of); Jeong, Kyeong Hoon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-06-15

    In this study, the natural frequencies of the perforated square plate with a square penetration pattern are obtained as a function of ligament efficiency using the commercial finite-element analysis code ANSYS. In addition, they are used to extract the effective modulus of elasticity under an assumption of a constant Poisson's ratio. The effective modulus of elasticity of the fully perforated square plate is applied to the modal analysis of a partially perforated square plate using a homogeneous finite-element analysis model. The natural frequencies and the corresponding mode shapes of the homogeneous model are compared with the results of the detailed finite-element analysis model of the partially perforated square plate to check the validity of the effective modulus of elasticity. In addition, the theoretical method to calculate the natural frequencies of a partially perforated square plate with fixed edges is suggested according to the Rayleigh-Ritz method.

  11. Analysis of fixed tilt and sun tracking photovoltaic–micro wind based hybrid power systems

    International Nuclear Information System (INIS)

    Sinha, Sunanda; Chandel, S.S.

    2016-01-01

    Graphical abstract: 6 kW_p photovoltaic–micro wind based hybrid power system analysis in a Indian Western Himalayan location. - Highlights: • Power generation by a roof mounted photovoltaic–micro wind hybrid system is explored. • Optimum hybrid configurations using fixed and sun tracking photovoltaic systems are determined. • Analysis of hybrid systems with optimally tilted and different sun tracking systems is presented. • Two axis sun tracking systems are found to generate 4.88–26.29% more energy than fixed tilt system. • Hybrid system installed at optimum tilt angle is found to be cost effective than a sun tracking system. - Abstract: In this study fixed tilt and sun tracking photovoltaic based micro wind hybrid power systems are analyzed along with determining the optimum configurations for a 6 kW_p roof mounted micro wind based hybrid system using fixed and tracking photovoltaic systems to enhance the power generation potential in a low windy Indian hilly terrain with good solar resource. The main objective of the study is to enhance power generation by focusing on photovoltaic component of the hybrid system. A comparative power generation analysis of different configurations of hybrid systems with fixed tilt, monthly optimum tilt, yearly optimum tilt and 6 different sun tracking photovoltaic systems is carried out using Hybrid Optimization Model for Electric Renewables. Monthly and seasonal optimum tilt angles determined for the location vary between 0° and 60° with annual optimum tilt angle as 29.25°. The optimum configurations for all sun tracking systems except for the two axis tracking system is found to be 7 kW_p photovoltaic system, one 5 kW_p wind turbine, 10 batteries and a 2 kW_p inverter. The optimum configuration for two axis tracking system and two types of fixed tilt systems, is found to be a 8 kW_p photovoltaic system, one 5 kW_p wind turbine, 10 batteries and a 2 kW_p inverter. The results show that horizontal axis with

  12. Growth and properties of the CuInS2 thin films produced by glancing angle deposition

    International Nuclear Information System (INIS)

    Akkari, F. Chaffar; Kanzari, M.; Rezig, B.

    2008-01-01

    We use the glancing angle deposition technique (GLAD) to grow CuInS 2 thin films by a vacuum thermal method onto glass substrates. During deposition, the substrate temperature was maintained at 200 deg. C. Due to shadowing effect the oblique angle deposition technique can produce nanorods tilted toward the incident deposition flux. The evaporated atoms arrive at the growing interface at a fixed angle θ measured from the substrate normal. The substrate is rotated with rotational speed ω fixed at 0.033 rev s -1 . We show that the use of this growth technique leads to an improvement in the optical properties of the films. Indeed high absorption coefficients (10 5 -3.10 5 cm -1 ) in the visible range and near-IR spectral range are reached. In the case of the absence of the substrate rotation, scanning electron microscopy pictures show that the structure of the resulting film consists of nanocolumns that are progressively inclined towards the evaporation source as the incident angle was increased. If a rapid azimuthal rotation accompanies the substrate tilt, the resulting nanostructure is composed of an array of pillars normal to the substrate. The surface morphology show an improvement without presence of secondary phases for higher incident angles (θ > 60 deg.)

  13. Fraturas odontomaxilares e mandibulares em eqüídeos tratados por diferentes técnicas de osteossíntese Odontomaxillares and mandibularies fractures in equides treated with different osteosynthesis techniques

    Directory of Open Access Journals (Sweden)

    G.E.S. Alves

    2008-12-01

    Full Text Available Oito eqüinos e um muar com fraturas odontomaxilares e mandibulares foram tratados com diferentes técnicas de osteossíntese modificadas, consistindo de cerclagens associadas ou não a bandas de tensão, placa de neutralização e pino intraosseo, sendo este aplicado com metodologia não encontrada na literatura consultada. Os procedimentos cirúrgicos nos eqüideos foram realizados com os animais em estação mediante contenção física, em brete, e química, com sedação ou neuroleptoanalgesia associada a bloqueios anestésicos regionais. Os animais apresentaram capacidade de mastigação e ingestão voluntária no pós-operatório imediato e recuperação óssea adequada.Eight equines and one mule with odontomaxillaries and mandibularies fractures were treated with different osteosynthesis modified techniques, consisting of cerclages with or without tension bands, neutralization plates, and intraosseous pin applied by a methodology which was not found in the literature. The surgery procedures in equides were performed with the animals in stand position under physical contention, sedation, or neuroleptoanalgesy and regional nerve block. All animals were able to eat voluntarily in the immediate post-operatory time and had good bone recuperation.

  14. Impact of interface charge on the electrostatics of field-plate assisted RESURF devices

    NARCIS (Netherlands)

    Boksteen, B.K.; Ferrara, A.; Heringa, A.; Steeneken, P.G.; Hueting, Raymond Josephus Engelbart

    2014-01-01

    A systematic study on the effects of arbitrary parasitic charge profiles, such as trapped or fixed charge, on the 2-D potential distribution in the drain extension of reverse-biased field-plate-assisted reduced surface field (RESURF) devices is presented. Using TCAD device simulations and analytical

  15. Intralaryngeal thyroarytaenoid lateralisation using the Fast-Fix 360 system: a canine cadaveric study.

    Science.gov (United States)

    Stegen, Ludo; Kitshoff, Adriaan M; Van Goethem, Bart; Vandekerckhove, Peter; de Rooster, Hilde

    2015-01-01

    Laryngeal paralysis is a condition in which failure of arytaenoid abduction results in a reduced rima glottidis cross-sectional area. The most commonly performed surgical techniques rely on unilateral abduction of the arytaenoid, requiring a lateral or ventral surgical approach to the larynx. The aim of the study was to investigate a novel minimally invasive intralaryngeal thyroarytaenoid lateralisation technique, using the Fast-Fix 360 meniscal repair system. Larynges were harvested from large breed canine cadavers. With the aid of Kirschner wires placed between the centre of the vocal process and the centre of an imaginary line between the cranial thyroid fissure and the cricothyroid articulation, the mean insertion angle was calculated. The Fast-Fix 360 delivery needle inserted intralaryngeally (n=10), according to a simplified insertion angle (70°), resulted in thyroid penetration (>2.5 mm from margin) in all patients. The Fast-Fix was applied unilaterally at 70° with the first toggle fired on the lateral aspect of the thyroid cartilage and inside the laryngeal cavity on retraction. The suture was tightened. Preprocedural (61.06±9.21 mm2) and postprocedural (138.37±26.12 mm2) rima glottidis cross-sectional area was significantly different (P<0.0001). The mean percentage increase in rima glottidis cross-sectional area was 125.96 per cent (±16.54 per cent). Intralaryngeal thyroarytaenoid laterlisation using the Fast-Fix 360 meniscal repair system ex vivo increased the rima glottidis cross-sectional area significantly.

  16. Optimum Energy Extraction from Coherent Vortex Rings Passing Tangentially Over Flexible Plates

    Science.gov (United States)

    Pirnia, Alireza; Browning, Emily A.; Peterson, Sean D.; Erath, Byron D.

    2017-11-01

    Coherent vortical structures can incite self-sustained oscillations in flexible membranes. This concept has recently gained interest for energy extraction from ambient environments. In this study the special case of a vortex ring passing tangentially over a cantilevered flexible plate is investigated. This problem is governed by the Kirchhoff-Love plate equation, which can be expressed in terms of a non-dimensional mass parameter of the plate, non-dimensional pressure loading induced by the vortex ring, and a Strouhal (St) number which expresses the duration of pressure loading relative to the period of plate oscillation. For a plate with a fixed mass parameter immersed in a fluid environment, the St number specifies the beam dynamics and the energy exchange process. The aim of this study is to identify the St number corresponding to maximum energy exchange between plates and vortex rings. The energy exchange process between the vortex ring and the plate is investigated over a range of 0.3 transfer is reported in each case and an empirical correlation is provided for predictive purposes. Supported by the National Science Foundation (NSF) under Grant No. CBET-1511761, and the Natural Sciences and Engineering Research Council of Canada (NSERC), under Grant No. 05778-2015.

  17. Finding Non-Zero Stable Fixed Points of the Weighted Kuramoto model is NP-hard

    OpenAIRE

    Taylor, Richard

    2015-01-01

    The Kuramoto model when considered over the full space of phase angles [$0,2\\pi$) can have multiple stable fixed points which form basins of attraction in the solution space. In this paper we illustrate the fundamentally complex relationship between the network topology and the solution space by showing that determining the possibility of multiple stable fixed points from the network topology is NP-hard for the weighted Kuramoto Model. In the case of the unweighted model this problem is shown...

  18. Comparison of closed-form and finite-element solutions of thick laminated anisotropic rectangular plates

    Energy Technology Data Exchange (ETDEWEB)

    Reddy, J N; Chao, W C [Virginia Polytechnic Inst. and State Univ., Blacksburg (USA). Dept. of Engineering Science and Mechanics

    1981-04-01

    In this study the effects of reduced integration, mesh size, and element type (i.e. linear or quadratic) on the accuracy of a penalty-finite element based on the theory governing thick, laminated, anisotropic composite plates are investigated. In order to assess the accuracy of the present finite element, exact closed-form solutions are developed for cross-ply and antisymmetric angle-ply rectangular plates simply supported and subjected to sinusoidally distributed mechanical and/or thermal loadings, and free vibration.

  19. Experimental investigations of the influence of thickness and mixed-mode loading on the crack initial angle in LC4-CS aluminum

    Science.gov (United States)

    Dong, Huiru; Guo, Wanlin; Yu, Liang

    2002-05-01

    The influence of thickness and mixed mode I/II loading on the crack initial angle of aluminum LC4-CS plates of 2, 4, 8 and 14 mm thickness was investigated experimentally from tensile-tearing testing of the compact-tension-shear type specimens. Experimental results of the crack initial angle for various thickness plates and load mode mixity were presented, and compared with theoretical predictions form the maximum tangential stress criterion and the maximum triaxial stress criterion. The crack initial angle is found to vary not only with load mode mixity but also with specimen thickness. The experimental result show a god agreement with theoretical predictions in 2, 14 mm- thickness specimens but a great deal difference in 8 mm-thickness specimens. The results are discussed in the viewpoint of 3D failure theory.

  20. Investigation of free vibration characteristics for skew multiphase magneto-electro-elastic plate

    Science.gov (United States)

    Kiran, M. C.; Kattimani, S.

    2018-04-01

    This article presents the investigation of skew multiphase magneto-electro-elastic (MMEE) plate to assess its free vibration characteristics. A finite element (FE) model is formulated considering the different couplings involved via coupled constitutive equations. The transformation matrices are derived to transform local degrees of freedom into the global degrees of freedom for the nodes lying on the skew edges. Effect of different volume fraction (Vf) on the free vibration behavior is explicitly studied. In addition, influence of width to thickness ratio, the aspect ratio, and the stacking arrangement on natural frequencies of skew multiphase MEE plate investigated. Particular attention has been paid to investigate the effect of skew angle on the non-dimensional Eigen frequencies of multiphase MEE plate with simply supported edges.

  1. Material and welding development of anchor plates to build nuclear power plant by blue arc process

    International Nuclear Information System (INIS)

    Gibelli, C.E.

    1986-01-01

    To build nuclear power plants, anchor plates are plenty used. These anchor plates serve as a system with the purpose to fix many heavy components or a simple stair. Considering the necessity of element fabrication fastly, with reasonable economy and quality, the arc study welding process (blue arc) was used. A special development of the material concept as well as a welding procedure and a subsuppliers qualification of the raw material was necessary. (Author) [pt

  2. Feasibility study on development of plate-type heat exchanger for BWR plants

    International Nuclear Information System (INIS)

    Ohyama, Nobuhiro; Suda, Kenichi; Ogata, Hiroshi; Matsuda, Shinichi; Nagasaka, Kazuhiro; Fujii, Toshi; Nozawa, Toshiya; Ishihama, Kiyoshi; Higuchi, Tomokazu

    2004-01-01

    In order to apply plate-type heat exchanger to RCW, TCW and FPC system in BWR plants, heat test and seismic test of RCW system heat exchanger sample were carried out. The results of these tests showed new design plate-type heat exchanger satisfied the fixed pressure resistance and seismic resistance and keep the function. The evaluation method of seismic design was constructed and confirmed by the results of tests. As anti-adhesion measure of marine organism, an ozone-water circulation method, chemical-feed method and combination of circulation of hot water and air bubbling are useful in place of the chlorine feeding method. Application of the plate-type heat exchanger to BWR plant is confirmed by these investigations. The basic principles, structure, characteristics, application limit and reliability are stated. (S.Y.)

  3. Bistatic radar cross section of a perfectly conducting rhombus-shaped flat plate

    Science.gov (United States)

    Fenn, Alan J.

    1990-05-01

    The bistatic radar cross section of a perfectly conducting flat plate that has a rhombus shape (equilateral parallelogram) is investigated. The Ohio State University electromagnetic surface patch code (ESP version 4) is used to compute the theoretical bistatic radar cross section of a 35- x 27-in rhombus plate at 1.3 GHz over the bistatic angles 15 deg to 142 deg. The ESP-4 computer code is a method of moments FORTRAN-77 program which can analyze general configurations of plates and wires. This code has been installed and modified at Lincoln Laboratory on a SUN 3 computer network. Details of the code modifications are described. Comparisons of the method of moments simulations and measurements of the rhombus plate are made. It is shown that the ESP-4 computer code provides a high degree of accuracy in the calculation of copolarized and cross-polarized bistatic radar cross section patterns.

  4. Acoustic impact on the laminated plates placed between barriers

    Science.gov (United States)

    Paimushin, V. N.; Gazizullin, R. K.; Fedotenkov, G. V.

    2016-11-01

    On the basis of previously derived equations, analytical solutions are established on the forced vibrations of two-layer and three-layers rectangular plates hinged in an opening of absolutely rigid walls during the transmission of monoharmonic sound waves. It is assumed that the partition wall is situated between two absolutely rigid barriers, one of them by harmonic oscillation with a given displacements amplitude on the plate forms the incident sound wave, and the other is stationary and has a coating of deformable energy absorbing material with high damping properties. The behavior of acoustic environments in the spaces between the deformable plate and the barriers described by classical wave equation based on the ideal compressible fluid model. To describe the process of dynamic deformation of the energy absorbing coating of fixed barrier, two-dimensional equations of motion based on the use of models transversely soft layer are derived with a linear approximation of the displacement field in the thickness direction of the coating and taking into account the damping properties of the material and the hysteresis model for it. The influence of the physical and mechanical properties of the concerned mechanical system and the frequency of the incident sound wave on the parameters of its insulation properties of the plate, as well as on the parameters of the stress-strain state of the plate has been analyzed.

  5. The Dual-Angle Method for Fast, Sensitive T1 Measurement in Vivo with Low-Angle Adiabatic Pulses

    Science.gov (United States)

    Bottomley, P. A.; Ouwerkerk, R.

    A new method for measuring T1 based on a measurement of the ratio, R, of the steady-state partially saturated NMR signals acquired at two fixed low flip angles (hip-angle and excitation-field ( B1) inhomogeneity result in roughly proportionate errors in the apparent T1. The method is best implemented with adiabatic low-angle pulses such as B1-independent rotation (BIR-4) or BIR-4 phase-cycled (BIRP) pulses, which permit measurements with surface coils. Experimental validation was obtained at 2 T by comparison of unlocalized inversion-recovery and dual-angle proton ( 1H) and phosphorus ( 31P) measurements from vials containing doped water with 0.04 ≤ T1 ≤ 2.8 s and from the metabolites in the calf muscles of eight human volunteers. Calf muscle values of 6 ± 0.5 s for phosphocreatine and around 3.7 ± 0.8 s for the adenosine triphosphates (ATP) were in good agreement with inversion-recovery T1 values and values from the literature. Use of the dual-angle method accelerated T1 measurement time by about fivefold over inversion recovery. The dual-angle method was implemented in a one-dimensional localized surface-coil 31P spectroscopy sequence, producing consistent T1 measurements from phantoms, the calf muscle, and the human liver. 31P T1 values of ATP in the livers of six volunteers were about 0.5 ± 0.1 to 0.6 ± 0.2 s: the total exam times were about 35 minutes per subject. The method is ideally suited to low-sensitivity and/or low-concentration moieties, such as in 31P NMR in vivo, where study-time limitations are critical, and for rapid 1H T1 imaging.

  6. Tunability of band structures in a two-dimensional magnetostrictive phononic crystal plate with stress and magnetic loadings

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Shunzu; Shi, Yang [Key Laboratory of Mechanics on Disaster and Environment in Western China attached to the Ministry of Education of China, Lanzhou University, Lanzhou, Gansu 730000 (China); Department of Mechanics and Engineering Sciences, College of Civil Engineering and Mechanics, Lanzhou University, Lanzhou, Gansu 730000 (China); Gao, Yuanwen, E-mail: ywgao@lzu.edu.cn [Key Laboratory of Mechanics on Disaster and Environment in Western China attached to the Ministry of Education of China, Lanzhou University, Lanzhou, Gansu 730000 (China); Department of Mechanics and Engineering Sciences, College of Civil Engineering and Mechanics, Lanzhou University, Lanzhou, Gansu 730000 (China)

    2017-03-26

    Considering the magneto-mechanical coupling of magnetostrictive material, the tunability of in-plane wave propagation in two-dimensional Terfenol-D/epoxy phononic crystal (PC) plate is investigated theoretically by the plane wave expansion method. Two Schemes, i.e. magnetic field is rotated in x–y plane and x–z plane, are studied, respectively. The effects of amplitude and direction of magnetic field, pre-stress and geometric parameters are discussed. For Scheme-I, band gap reaches the maximum at an optimal angle 45° of magnetic field. However, the optimal angle is 0° for Scheme-II, because band gap decreases monotonically until disappears with the increasing angle. For both cases, higher-order band gaps generate and become stronger as magnetic field amplitude increases, while increasing compressive pre-stress has the opposite effect. Meanwhile, filling fraction plays a key role in controlling band gaps. These results provide possibility for intelligent regulation and optimal design of PC plates. - Highlights: • The in-plane wave propagation in phononic crystal thin plate is tuned theoretically. • Magnetostrictive material is introduced in the study. • The effects of magnetic field and pre-stress are considered. • The variations of band gaps with external stimuli are discussed.

  7. Free vibration analysis of perforated plate with square penetration pattern using equivalent material properties

    Directory of Open Access Journals (Sweden)

    Myung Jo Jhung

    2015-06-01

    Full Text Available In this study, the natural frequencies of the perforated square plate with a square penetration pattern are obtained as a function of ligament efficiency using the commercial finite-element analysis code ANSYS. In addition, they are used to extract the effective modulus of elasticity under an assumption of a constant Poisson's ratio. The effective modulus of elasticity of the fully perforated square plate is applied to the modal analysis of a partially perforated square plate using a homogeneous finite-element analysis model. The natural frequencies and the corresponding mode shapes of the homogeneous model are compared with the results of the detailed finite-element analysis model of the partially perforated square plate to check the validity of the effective modulus of elasticity. In addition, the theoretical method to calculate the natural frequencies of a partially perforated square plate with fixed edges is suggested according to the Rayleigh–Ritz method.

  8. A study on the variation of maxillary sinus volume and projection angle in children for CT scan

    International Nuclear Information System (INIS)

    Ji, Youn Sang; Dong, Kyung Rae; Choi, Seong Kwan; Kim, Mi Hyun; Jung, Myung Jin; Yeo, Hwa Yeon

    2017-01-01

    The Water's view is that you can examine and diagnose disease of the maxillary sinus and implemented a simple and economical because a lot of tests. Because changes in the size of the maxillary sinus and skull growth in volume, depending on the disease that occurs in children often differ from the baseline angle of the water's view that it is easy to observe. Through Computed tomography (CT) and volumetric analysis and Orbitmeatal line (OML) and Image plate (IP) is the angle and evaluate the appropriate Water's view angle in children

  9. Modeling particulate removal in plate-plate and wire-plate electrostatic precipitators

    Directory of Open Access Journals (Sweden)

    S Ramechecandane

    2016-09-01

    Full Text Available The present study is concerned with the modeling of electrically charged particles in a model plate-plate and a single wire-plate electrostatic precipitator (ESP. The particle concentration distributions for both a plate-plate and a wire-plate ESP are calculated using a modified drift flux model. Numerical investigations are performed using the modified drift flux model for particle number concentration, in addition to the RNG k - ε model for the mean turbulent flow field and the Poisson equation for the electric field. The proposed model and the outlined methodology for coupling the flow field, electric field, charging kinetics and particle concentration is applied to two model precipitators that are truly representative of a wide class of commercialized ESPs. The present investigation is quite different from the earlier studies as it does not make assumptions like a homogeneous electric field or an infinite turbulent diffusivity. The electric field calculated is a strong function of position and controls the migration velocity of particles. Hence, the proposed model can be implemented in a flow solver to obtain a full-fledged solution for any kind of ESP with no limitations on the particle number concentration, as encountered in a Lagrangian approach. The effect of turbulent diffusivity on particle number concentration in a plate-plate ESP is investigated in detail and the results obtained are compared with available experimental data. Similarly, the effect of particle size/diameter and applied electric potential on the accumulative collection performance in the case of a wire-plate ESP is studied and the results obtained are compared with available numerical data. The numerical results obtained using the modified drift flux model for both the plate-plate and wire-plate ESP are in close agreement with available experimental and numerical data.

  10. Osteosíntesis mini-invasiva con placas bloqueadas en fracturas metafisarias distales de tibia. Resultados clínico-funcionales. [Minimally invasive plate osteosynthesis in distal metaphyseal fractures of tibia. Comparison of results between fractures AO 43A and AO 43C.

    Directory of Open Access Journals (Sweden)

    Juan Manuel Yañez Arauz

    2015-05-01

    Full Text Available Introducción Las fracturas distales de tibia son un desafío para el tratamiento debido a la escasa cobertura y particular vascularización. Los objetivos del presente estudio son analizar los resultados clínicos y funcionales de los pacientes con fractura de tibia distal; tratados con técnica MIPO (minimally invasive plate osteosynthesis con placas bloqueadas; comparar los resultados del grupo de fracturas tipo AO 43A con las tipo AO 43C1-C2; y comparar los resultados MIPO con el tratamiento abierto convencional.   Material y métodos Entre 2004 y 2012, se evaluaron 32 fracturas de tibia distal tratadas con técnica MIPO. 20 varones y 12 mujeres. Edad promedio: 40,1 años. El 59,4% presentó fracturas tipo AO 43A; y el 40,6% AO 43C. Tiempo trauma/cirugía: 6,8 días promedio. 24 casos presentaron fractura de peroné. Estadía hospitalaria: 1,5 días promedio. Seguimiento promedio: 39,6 meses, mediante score AOFAS y radiología. Se consignaron complicaciones. Se compararon resultados de grupos  tipo AO A y los tipo AO C.   Resultados Incremento del score AOFAS entre pre y post-operatorio: 73,3 puntos promedio. El grupo AO tipo A: media de 95,89 puntos AOFAS PO. El grupo AO tipo C1-2: media de 92,15 puntos PO. Carga del peso corporal: a las 8,7 semanas promedio. Comparando A= 43A y AO 43C: p: 0,46 (no significativa. Retorno a actividad previa a la lesión:9.3 meses promedio. Comparando tipo A y tipo C: p=0,16 (no significativa. Hubo 18,75% de complicaciones y retiro de osteosíntesis en 14 casos.  Conclusiones  La osteosíntesis mínimamente invasiva con placa y tornillos, es una buena opción para las fracturas de tibia distal; con buena evolución clínico-funcional, y escasas complicaciones comparadas a la cirugía abierta. Las fracturas 43A presentan menos complicaciones mayores que las 43C, tratadas con técnica MIPO.

  11. Biomechanical and biological aspects of defect treatment in fractures using helical plates.

    Science.gov (United States)

    Perren, S M; Regazzoni, P; Fernandez, A A D

    2014-01-01

    conventional plate is the extent of surgical trauma at the critical site of healing. - Shingling and/or applying an autologous cancellous bone graft: This procedure provides initially no relevant load sharing but will do so after a couple of weeks. The mechanical coupling of the comparably soft graft and the main fracture fragments presents little problems. Applying a cortical bone graft: Such a graft does provide initial only small load sharing and does a less good job inducing callus than a cancellous graft. Furthermore, the coupling by callus between a somewhat rigid bone graft and the mobile main fracture fragments requires a solid maintained contact. If the cortical graft is fixed using implants with small contact area to the graft such as screws or cerclage loops, the local stress may be critical and the graft may break. When the cortical graft is fixed with cerclage wires the procedure must take into account the limited strength of the individual cerclage. Therefore multiple and well-spaced cerclages are required and may lead to success especially if an intramedullary component of the implant contributes to protection (6). The degree of unloading depends apparently on the stiffness of the material of the protecting splint. Though, more important is the effect of the dimensions of the splint. While titanium as a material is about 50% less stiff than steel, the thickness of the implant changes the stiffness with the third power. That is doubling the thickness results in eightfold increased stiffness. When considering the unloading by application of a second plate the leverage of the second plate plays an important role. The larger the distance between the axis of bending and the second implant the larger the protecting effect. The helical plate (2, 3, 7) as introduced by A.A.D. Fernandez offers biological and mechanical advantages. It can be applied without touching the fracture site maintaining the critical biology intact and provides mechanically efficient unloading

  12. Numerical study of hub taper angle on podded propeller performance

    International Nuclear Information System (INIS)

    Islam, M.F.; Veitch, B.; Bose, N.; Liu, P.

    2005-01-01

    Presently, the majority of podded propulsion systems are of the pulling type, because this type provides better hydrodynamic efficiency than the pushing type. There are several possible explanations for the better overall performance of a puller type podded propulsor. One is related to the difference in hub shape. Puller and pusher propellers have opposite hub taper angles, hence different hub and blade root shape. These differences cause changes in the flow condition and possibly influence the overall performance. The current study focuses on the variation in performance of pusher and puller propellers with the same blade sections, but different hub taper angles. A hyperboloidal low order source doublet steady/unsteady time domain panel method code was modified and used to evaluate effects of hub taper angle on the open water propulsive performance of some fixed pitch screw propellers used in podded propulsion systems. The modified code was first validated against measurements of two model propellers in terms of average propulsive performance and good agreement was found. Major findings include significant effects of hub taper angle on propulsive performance of tapered hub propellers and noticeable effects of hub taper angle on sectional pressure distributions of tapered hub propeller blades. (author)

  13. Author Details

    African Journals Online (AJOL)

    Outcome of plate osteosynthesis in the management of proximal humeral fractures in adults. Abstract PDF · Vol 6, No 1 (2012) - Articles Management of Acute Musculoskeletal Pain: A Review Abstract PDF · Vol 7, No 1 (2013) - Articles Early weight-bearing after ankle fracture fixation: a prospective randomized and ...

  14. In vivo analysis of acromioclavicular joint motion after hook plate fixation using three-dimensional computed tomography.

    Science.gov (United States)

    Kim, Yoon Sang; Yoo, Yon-Sik; Jang, Seong Wook; Nair, Ayyappan Vijayachandran; Jin, Hyonki; Song, Hyun-Seok

    2015-07-01

    The clavicle hook plate can be used to treat acromioclavicular and coracoclavicular ligament injury or distal clavicular fracture with comminution. However, the hook plate can induce subacromial impingement, resulting in discomfort from the hardware. Our inclusion criteria were (1) men and women aged older than 20 years and (2) the presence of comminuted distal clavicular fractures (Neer type IIB) fixed with a hook plate (Synthes, Oberdorf, Switzerland). Three-dimensional computed tomography was obtained before removal of the hook plate. Seven patients were enrolled prospectively. The mean age was 42 years (range, 24-60 years). Zero degree images and abduction images were obtained. The sagittal cut surface was obtained 5 mm medial from the distal clavicle. The equator of the cut surface of the clavicle was compared with the full abduction model to analyze rotation. The center of the cut surface of the clavicle was compared with the full abduction model to analyze translation. The average difference in rotation of the distal clavicle between both shoulders was 16° (range, 3°-22°; P = .001). The mean difference in anterior translation of the distal clavicle was 2.2 mm (range, -0.7 to 5.6 mm; P = .030). Hook plate fixation at the acromioclavicular joint causes decreased internal rotation and increased anterior translation of the distal clavicle with respect to the medial acromion, indicating that the scapula relative to the thorax has decreased posterior tilting and increased external rotation in shoulders fixed using a hook plate. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  15. Collapsed heteroclinic snaking near a heteroclinic chain in dragged meniscus problems.

    Science.gov (United States)

    Tseluiko, D; Galvagno, M; Thiele, U

    2014-04-01

    A liquid film is studied that is deposited onto a flat plate that is inclined at a constant angle to the horizontal and is extracted from a liquid bath at a constant speed. We analyse steady-state solutions of a long-wave evolution equation for the film thickness. Using centre manifold theory, we first obtain an asymptotic expansion of solutions in the bath region. The presence of an additional temperature gradient along the plate that induces a Marangoni shear stress significantly changes these expansions and leads to the presence of logarithmic terms that are absent otherwise. Next, we numerically obtain steady solutions and analyse their behaviour as the plate velocity is changed. We observe that the bifurcation curve exhibits collapsed (or exponential) heteroclinic snaking when the plate inclination angle is above a certain critical value. Otherwise, the bifurcation curve is monotonic. The steady profiles along these curves are characterised by a foot-like structure that is formed close to the meniscus and is preceded by a thin precursor film further up the plate. The length of the foot increases along the bifurcation curve. Finally, we prove with a Shilnikov-type method that the snaking behaviour of the bifurcation curves is caused by the existence of an infinite number of heteroclinic orbits close to a heteroclinic chain that connects in an appropriate three-dimensional phase space the fixed point corresponding to the precursor film with the fixed point corresponding to the foot and then with the fixed point corresponding to the bath.

  16. [PERSONALIZED DISTAL FEMORAL VALGUS RESECTION ANGLE IN PRIMARY TOTAL KNEE ARTHROPLASTY].

    Science.gov (United States)

    Wang, Xilong; Shang, Xifu; Ll, Guoyuan; He, Rui; Zheng, Jie

    2015-01-01

    To investigate the feasibility and effectiveness of a personalized distal femoral valgus resection angle for improving postoperative coronal alignment of lower limb in total knee arthroplasty (TKA). A retrospective analysis was made on the clinical data of 50 patients who received primary TKA between January 2013 and February 2013. There were 11 male and 39 female patients with degenerative knee osteoarthritis. The patients were divided into 2 groups. In test group (n=25), the resection angle was adjusted to the femoral mechanical anatomical angle (FMA); in control group (n=25), a fixed distal valgus resection angle of 5° was used. There was no significant difference in gender, age, body mass index, disease duration, sides, grade, preoperative FMA, mechanical femorotibial angle (MFT), and preoperative Knee Society Score (KSS) between 2 groups (P > 0.05). Whole long X-ray film was taken to measure FMA and MFT at 3 days after operation, postoperative KSS was used to evaluate the knee function after 6 and 15 months. MFT was (-0.20 ± 1.87)° in test group and was (1.71 ± 3.67)° in control group, showing significant difference between 2 groups (t = 2.32, P = 0.02). The ideal MFT angle (0 ± 3)° was achieved in 22 patients (88%) of test group and in 16 patients (64%) of control group, showing significant difference between 2 groups (χ2 = 2.32, P = 0.02). Primary healing of incision was obtained in all patients of 2 groups. No deep venous thrombosis occurred. The patients of 2 groups were followed up 15 months after operation. There was significant difference in KSS between test and control groups at 6 months (88.23 ± 2.57 vs. 82.92 ± 2.59) (t = 7.26, P = 0.00) and at 15 months (90.76 ± 2.77 vs. 88.65 ± 1.77) (t = 3.20, P = 0.02). No sign of prosthesis loosening was observed by X-ray examination. Compared with using of a fixed distal femoral resection angle, an individual FMA can significantly improve the postoperative MFT and promote early recovery of the knee

  17. Bilateral Acute Angle-Closure Glaucoma Induced By Escitalopram

    Directory of Open Access Journals (Sweden)

    Dilbade Yıldız Ekinci

    2014-10-01

    Full Text Available Escitalopram is an antidepressant of the selective serotonin reuptake inhibitor(SSRI class. In this manuscript, we report the case of a female patient who developed bilateral acute angle-closure glaucoma induced by escitalopram. A 46-year-old female patient was admitted to our ophthalmology clinic with complaints of severe pain around the both eyes, headache, nausea, and vomiting for two days. In her past medical history, she was using escitalopram for depression for two years. Visual acuity was at hand movement level in both eyes. Anterior segment examination showed bilateral diffuse conjunctival hyperemia, corneal edema, shallow anterior chamber, and fixed dilated pupils. Intraocular pressure was 47 mmHg in the right and 68 mmHg in the left eye. The diagnosis was acute angle-closure glaucoma, and the escitalopram medication was discontinued. She was treated with topical and systemic antiglaucomatous medication. After the cornea become clear, bilateral peripheral laser iridotomy was done. In the following year, she did not begin escitalopram medication again and no other acute angle-closure attack was seen. (Turk J Ophthalmol 2014; 44:396-9

  18. Hybrid method for consistent model of the Pacific absolute plate motion and a test for inter-hotspot motion since 70Ma

    Science.gov (United States)

    Harada, Y.; Wessel, P.; Sterling, A.; Kroenke, L.

    2002-12-01

    Inter-hotspot motion within the Pacific plate is one of the most controversial issues in recent geophysical studies. However, it is a fact that many geophysical and geological data including ages and positions of seamount chains in the Pacific plate can largely be explained by a simple model of absolute motion derived from assumptions of rigid plates and fixed hotspots. Therefore we take the stand that if a model of plate motion can explain the ages and positions of Pacific hotspot tracks, inter-hotspot motion would not be justified. On the other hand, if any discrepancies between the model and observations are found, the inter-hotspot motion may then be estimated from these discrepancies. To make an accurate model of the absolute motion of the Pacific plate, we combined two different approaches: the polygonal finite rotation method (PFRM) by Harada and Hamano (2000) and the hot-spotting technique developed by Wessel and Kroenke (1997). The PFRM can determine accurate positions of finite rotation poles for the Pacific plate if the present positions of hotspots are known. On the other hand, the hot-spotting technique can predict present positions of hotspots if the absolute plate motion is given. Therefore we can undertake iterative calculations using the two methods. This hybrid method enables us to determine accurate finite rotation poles for the Pacific plate solely from geometry of Hawaii, Louisville and Easter(Crough)-Line hotspot tracks from around 70 Ma to present. Information of ages can be independently assigned to the model after the poles and rotation angles are determined. We did not detect any inter-hotspot motion from the geometry of these Pacific hotspot tracks using this method. The Ar-Ar ages of Pacific seamounts including new age data of ODP Leg 197 are used to test the newly determined model of the Pacific plate motion. The ages of Hawaii, Louisville, Easter(Crough)-Line, and Cobb hotspot tracks are quite consistent with each other from 70 Ma to

  19. Complications and Reoperations in Mandibular Angle Fractures.

    Science.gov (United States)

    Chen, Collin L; Zenga, Joseph; Patel, Ruchin; Branham, Gregory

    2018-05-01

    Mandible angle fractures can be repaired in a variety of ways, with no consensus on the outcomes of complications and reoperation rates. To analyze patient, injury, and surgical factors, including approach to the angle and plating technique, associated with postoperative complications, as well as the rate of reoperation with regard to mandible angle fractures. Retrospective cohort study analyzing the surgical outcomes of patients with mandible angle fractures between January 1, 2000, and December 31, 2015, who underwent open reduction and internal fixation. Patients were eligible if they were aged 18 years or older, had 3 or less mandible fractures with 1 involving the mandibular angle, and had adequate follow-up data. Patients with comminuted angle fractures, bilateral angle fractures, and multiple surgical approaches were excluded. A total of 135 patients were included in the study. All procedures were conducted at a single, large academic hospital located in an urban setting. Major complications and reoperation rates. Major complications included in this study were nonunion, malunion, severe malocclusion, severe infection, and exposed hardware. Of 135 patients 113 (83.7%) were men; median age was 29 years (range, 18-82 years). Eighty-seven patients (64.4%) underwent the transcervical approach and 48 patients (35.6%) received the transoral approach. Fifteen (17.2%) patients in the transcervical group and 9 (18.8%) patients in the transoral group experienced major complications (difference, 1%; 95% CI, -8% to 10%). Thirteen (14.9%) patients in the transcervical group and 8 (16.7%) patients in the transoral group underwent reoperations (difference, 2%; 95% CI, -13% to 17%). Active smoking had a significant effect on the rate of major complications (odds ratio, 4.04; 95% CI, 1.07 to 15.34; P = .04). During repair of noncomminuted mandibular angle fractures, both of the commonly used approaches-transcervical and transoral-can be used during treatment with equal

  20. Nonlinear vibrations of thin arbitrarily laminated composite plates subjected to harmonic excitations using DKT elements

    Science.gov (United States)

    Chiang, C. K.; Xue, David Y.; Mei, Chuh

    1993-04-01

    A finite element formulation is presented for determining the large-amplitude free and steady-state forced vibration response of arbitrarily laminated anisotropic composite thin plates using the Discrete Kirchhoff Theory (DKT) triangular elements. The nonlinear stiffness and harmonic force matrices of an arbitrarily laminated composite triangular plate element are developed for nonlinear free and forced vibration analyses. The linearized updated-mode method with nonlinear time function approximation is employed for the solution of the system nonlinear eigenvalue equations. The amplitude-frequency relations for convergence with gridwork refinement, triangular plates, different boundary conditions, lamination angles, number of plies, and uniform versus concentrated loads are presented.

  1. Ilizarov external fixation versus plate osteosynthesis in the management of extra-articular fractures of the distal tibia.

    Science.gov (United States)

    Fadel, Mohamed; Ahmed, Mohamed Ali; Al-Dars, Ahmed Mounir; Maabed, Mustafa Ahmed; Shawki, Hashem

    2015-03-01

    The purpose of this study was to evaluate the outcome of Ilizarov external fixation (IE) versus dynamic compression plate (PO) in the management of extra-articular distal tibial fractures. Between 2010 and 2011, extra-articular distal tibial fractures in 40 consecutive patients met the inclusion criteria. They were classified according to AO classification fracture type A (A1, A2, and A3). In a randomized method, two equal groups were managed using either IE or PO. PO was performed using open reduction and internal fixation (ORIF) and DCP through anterolateral approach. IE was done using Ilizarov frame. For the PO group, non-weight bearing ambulation was permitted on the second postoperative day but partial weight bearing was permitted according to the progression in union criteria clinically and radiologically. For the IE group, weight bearing started as tolerated from the first postoperative day. Physiotherapy and pin-site care was performed by the patient themselves. Modified Mazur ankle score was applied to IE (excellent 10, good 10) and in PO (excellent 2, good 8, poor 6). Data were statically analysed using (Mann-Whitney test). The rate of healing in the IE group (average 130) was higher than the PO (average 196.5); plus, there were no cases of delayed union or nonunion in the IE group (p value 0.003). It was found that IE compared with PO provides provision of immediate weight bearing as tolerated following postoperative recovery, irrespective of radiological or clinical healing with no infection, deformity or non-union.

  2. C6 plate puncture testing report.

    Energy Technology Data Exchange (ETDEWEB)

    Vangoethem, Douglas J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Cordova, Theresa Elena [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Reu, Phillip L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2013-04-01

    There are numerous scenarios where critical systems could be subject to penetration by projectiles or fixed objects (e.g., collision, natural disaster, act of terrorism, etc.). It is desired to use computational models to examine these scenarios and make risk-informed decisions; however, modeling of material failure is an active area of research, and new models must be validated with experimental data. The purpose of this report is to document the experimental work performed from FY07 through FY08 on the Campaign Six Plate Puncture project. The goal of this project was to acquire experimental data on the puncture and penetration of metal plates for use in model validation. Of particular interest is the PLH failure model also known as the multilinear line segment model. A significant amount of data that will be useful for the verification and validation of computational models of ductile failure were collected during this project were collected and documented herein; however, much more work remains to be performed, collecting additional experimental data that will further the task of model verification.

  3. [Tibiotalocalcaneal arthrodesis using a humeral locking plate].

    Science.gov (United States)

    Cabrera Méndez, M P; Gamba, C; Hernández, E; Molano, J; Andrade, J C

    2016-01-01

    To describe the results of tibiotalocalcáneal arthrodesis (TTC) using a humeral locking plate. A retrospective, observational study was conducted between January 2007 and December 2013 in the Hospital Militar Central de Bogotá. The study included patients with symptomatic osteoarthritis diagnosed clinically and radiologically, and who underwent TTC arthrodesis using a humeral locking plate with a minimum follow up of 6 months. The total number patients was 35, of whom 7 (20%) were women and 28 (80%) men, with a mean age 36.3 years (19.77). 74% with post-traumatic arthritis, most of them secondary to gunshot wounds and fragmentation weapons, and neuropathic in 20%. An autogenous graft was used in 13 cases, and 14 cases using both, with a mean consolidation time of 4.37 months. Complications include, delayed union in 3 cases, and surgical site infection in 4. The postoperative functionality (AOFAS) mean was 66.7/100 points, with a score of 2.35 on a visual analogue pain scale. TTC arthrodesis using a humeral locking plate is a suitable option for fixing this type of arthrodesis, with a low rate of complications, and postoperative results that revealed satisfactory improvement in pain and consolidation. Copyright © 2015 SECOT. Published by Elsevier Espana. All rights reserved.

  4. Reflection of Lamb waves obliquely incident on the free edge of a plate.

    Science.gov (United States)

    Santhanam, Sridhar; Demirli, Ramazan

    2013-01-01

    The reflection of obliquely incident symmetric and anti-symmetric Lamb wave modes at the edge of a plate is studied. Both in-plane and Shear-Horizontal (SH) reflected wave modes are spawned by an obliquely incident in-plane Lamb wave mode. Energy reflection coefficients are calculated for the reflected wave modes as a function of frequency and angle of incidence. This is done by using the method of orthogonal mode decomposition and by enforcing traction free conditions at the plate edge using the method of collocation. A PZT sensor network, affixed to an Aluminum plate, is used to experimentally verify the predictions of the analysis. Experimental results provide support for the analytically determined results. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Time dependent shear stress and temperature distribution over an insulated flat plate moving at hypersonic speed.

    Science.gov (United States)

    Rodkiewicz, C. M.; Gupta, R. N.

    1971-01-01

    The laminar two-dimensional flow over a stepwise accelerated flat plate moving with hypersonic speed at zero angle of attack is analysed. The governing equations in the self-similar form are linearized and solved numerically for small times. The solutions obtained are the deviations of the velocity and the temperature profiles from those of steady state. The presented results may be used to find the first order boundary layer induced pressure on the plate.

  6. Subduction and Plate Edge Tectonics in the Southern Caribbean

    Science.gov (United States)

    Levander, A.; Schmitz, M.; Niu, F.; Bezada, M. J.; Miller, M. S.; Masy, J.; Ave Lallemant, H. G.; Pindell, J. L.; Bolivar Working Group

    2013-05-01

    The southern Caribbean plate boundary consists of a subduction zone at at either end of a complex strike-slip fault system: In the east at the Lesser Antilles subduction zone, the Atlantic part of the South American plate subducts beneath the Caribbean. In the north and west in the Colombia basin, the Caribbean subducts under South America. In a manner of speaking, the two plates subduct beneath each other. Finite-frequency teleseismic P-wave tomography confirms this, imaging the Atlantic and the Caribbean plates subducting steeply in opposite directions to transition zone depths under northern South America (Bezada et al, 2010). The two subduction zones are connected by the El Pilar-San Sebastian strike-slip fault system, a San Andreas scale system that has been cut off at the Bocono fault, the southeastern boundary fault of the Maracaibo block. A variety of seismic probes identify subduction features at either end of the system (Niu et al, 2007; Clark et al., 2008; Miller et al. 2009; Growdon et al., 2009; Huang et al., 2010; Masy et al, 2011). The El Pilar system forms at the southeastern corner of the Antilles subduction zone with the Atlantic plate tearing from South America. The deforming plate edges control mountain building and basin formation at the eastern end of the strike-slip system. Tearing the Atlantic plate from the rest of South America appears to cause further lithospheric instability continentward. In northwestern South America the Caribbean plate very likely also tears, as its southernmost element subducts at shallow angles under northernmost Colombia but then rapidly descends to the transition zone under Lake Maracaibo (Bezada et al., 2010). We believe that the flat slab controls the tectonics of the Neogene Merida Andes, Perija, and Santa Marta ranges. The nonsubducting part of the Caribbean plate also underthrusts northern Venezuela to about the width of the coastal mountains (Miller et al., 2009). We infer that the edge of the underthrust

  7. Device for removing and recuperating sludge deposited on the tube plate of a steam generator

    International Nuclear Information System (INIS)

    Bes, Louis.

    1982-01-01

    The cleaning device includes a descaling ramp with high pressure jets permanently fixed inside the steam generator, a system for driving the sludge formed towards the centre of the tube plate and a valve for removing the sludge giving into a hollow central column [fr

  8. Non-Newtonian ink transfer in gravure-offset printing

    International Nuclear Information System (INIS)

    Ghadiri, Fatemeh; Ahmed, Dewan Hasan; Sung, Hyung Jin; Shirani, Ebrahim

    2011-01-01

    The inks used in gravure-offset printing are non-Newtonian fluids with higher viscosities and lower surface tensions than Newtonian fluids. This paper examines the transfer of a non-Newtonian ink between a flat plate and a groove when the plate is moved upward with a constant velocity while the groove is held fixed. Numerical simulations were carried out with the Carreau model to explore the behavior of this non-Newtonian ink in gravure-offset printing. The volume of fluid (VOF) method was implemented to capture the interface during the ink transfer process. The effects of varying the contact angle of the ink on the flat plate and groove walls and geometrical parameters such as the groove angle and the groove depth on the breakup time of the liquid filament that forms between the plate and the groove and the ink transfer ratio were determined. Our results indicate that increasing the groove contact angle and decreasing the flat plate contact angle enhance the ink transfer ratio and the breakup time. However, increasing the groove depth and the groove angle decreases the transfer ratio and the breakup time. By optimizing these parameters, it is possible to achieve an ink transfer from the groove to the flat plate of approximately 92%. Moreover, the initial width and the vertical velocity of the neck of the ink filament have significant influences on the ink transfer ratio and the breakup time.

  9. Numerical investigation of unsteady mixing mechanism in plate film cooling

    Directory of Open Access Journals (Sweden)

    Shuai Li

    2016-09-01

    Full Text Available A large-scale large eddy simulation in high performance personal computer clusters is carried out to present unsteady mixing mechanism of film cooling and the development of films. Simulation cases include a single-hole plate with the inclined angle of 30° and blowing ratio of 0.5, and a single-row plate with hole-spacing of 1.5D and 2D (diameters of the hole. According to the massive simulation results, some new unsteady phenomena of gas films are found. The vortex system is changed in different position with the development of film cooling with the time marching the process of a single-row plate film cooling. Due to the mutual interference effects including mutual exclusion, a certain periodic sloshing and mutual fusion, and the structures of a variety of vortices change between parallel gas films. Macroscopic flow structures and heat transfer behaviors are obtained based on 20 million grids and Reynolds number of 28600.

  10. Vortex-Induced Vibrations of a Flexibly-Mounted Cyber-Physical Rectangular Plate

    Science.gov (United States)

    Onoue, Kyohei; Strom, Benjamin; Song, Arnold; Breuer, Kenneth

    2013-11-01

    We have developed a cyber-physical system to explore the vortex-induced vibration (VIV) behavior of a flat plate mounted on a virtual spring damper support. The plate is allowed to oscillate about its mid-chord and the measured angular position, velocity, and torque are used as inputs to a feedback control system that provides a restoring torque and can simulate a wide range of structural dynamic behavior. A series of experiments were carried out using different sized plates, and over a range of freestream velocities, equilibrium angles of attack, and simulated stiffness and damping. We observe a synchronization phenomenon over a wide range of parameter space, wherein the plate oscillates at moderate to large amplitude with a frequency dictated by the natural structural frequency of the system. Additionally, the existence of bistable states is reflected in the hysteretic response of the system. The cyber-physical damping extracts energy from the flow and the efficiency of this harvesting mechanism is characterized over a range of dimensionless stiffness and damping parameters. This research is funded by the Air Force Office of Scientific Research (AFOSR).

  11. Modification of the morphology and optical properties of SnS films using glancing angle deposition technique

    Energy Technology Data Exchange (ETDEWEB)

    Sazideh, M.R., E-mail: Mohammadrezasazideh@gmail.com [Thin Film Lab., Faculty of Physics, Semnan University, Semnan, Islamic Republic of Iran (Iran, Islamic Republic of); Dizaji, H. Rezagholipour, E-mail: hrgholipour@semnan.ac.ir [Faculty of Physics, Semnan University, P.O. Box: 35195-363, Semnan, Islamic Republic of Iran (Iran, Islamic Republic of); Ehsani, M.H., E-mail: mhe_ehsani@yahoo.com [Faculty of Physics, Semnan University, P.O. Box: 35195-363, Semnan, Islamic Republic of Iran (Iran, Islamic Republic of); Moghadam, R. Zarei, E-mail: r.zarei1991@gmail.com [Thin Film Lab., Faculty of Physics, Semnan University, Semnan, Islamic Republic of Iran (Iran, Islamic Republic of)

    2017-05-31

    Highlights: • SnS thin films produced by thermal evaporation method using glancing angle deposition technique. • At α = 85° the layers show a considerable change in effective refractive index (Δn = 1.7) at near-IR spectral range. • FESEM images showed drastic changes in the structure and morphology of individual nano-plates as a function of incident angle deposition. - Abstract: Tin sulfide (SnS) films were prepared by thermal evaporation method using Glancing Angle Deposition (GLAD) technique at zero and different oblique incident flux angles (α = 45°, 55°, 65°, 75° and 85°). The physical properties of prepared films were systematically investigated. The X-ray diffraction analysis indicated that the film deposited at α = 0° formed as single phase with an orthorhombic structure. However, the layers became amorphous at α = 45°, 55°, 65°, 75° and 85°. Beside the appearance of amorphous feature in the film prepared at α higher than zero, Sn{sub 2}S{sub 3} phase was also observed. The top and cross-sectional field emission scanning electron microscope (FESEM) images of the samples showed noticeable changes in the structure and morphology of individual nano-plates as a function of incident angle. The band gap and refractive index values of the films were calculated by optical transmission measurements. The optical band-gap values were observed to increase with increasing the incident flux angle. This can be due to presence of Sn{sub 2}S{sub 3} phase observed in the samples produced at α values other than zero. The effective refractive index and porosity exhibit an opposite evolution as the incident angle α rises. At α = 85° the layers show a considerable change in effective refractive index (Δn = 1.7) at near-IR spectral range.

  12. Low velocity impact of 6082-T6 aluminum plates

    Science.gov (United States)

    Mocian, Oana Alexandra; Constantinescu, Dan Mihai; Sandu, Marin; Sorohan, Ştefan

    2018-02-01

    The low velocity domain covers vehicle impacts, ship collisions and even accidentally tool drops. Even though more and more research is needed into these fields, most of the papers concerning impact problems focus on impact at medium and high velocities. Understanding the behavior of structures subjected to low velocity impact is of major importance when referring to impact resistance and damage tolerance. The paper presents an experimental and numerical investigation on the low velocity behavior of 6082-T6 aluminum plates. Impact tests were performed using an Instron Ceast 9340 drop-weight testing machine. In the experimental procedure, square plates were mounted on a circular support, fixed with a pneumatic clamping system and impacted with a hemispherical steel projectile. Specimens were impacted at constant weight and different impact velocities. The effect of different impact energies was investigated. The impact event was then simulated using the nonlinear finite element code LS_DYNA in order to determine the effect of strain rate upon the mechanical behavior of the aluminum plates. Moreover, in order to capture the exact behavior of the material, a special attention has been given to the selection of the correct material model and its parameters, which, in large extent, depend on the observed behavior of the aluminum plate during the test and the actual response of the plate under simulation. The numerical predictions are compared with the experimental observations and the applicability of the numerical model for further researches is analyzed.

  13. Biomechanical comparison of transoral and transbuccal lateral ...

    African Journals Online (AJOL)

    Objectives: The purpose of this experimental study was to compare the biomechanical behaviors of two different types of osteosynthesis that are used in the treatment of mandibular angle fractures. Materials and Methods: Twenty synthetic polyurethane human mandible replicas, with medullar and cortical portions, were ...

  14. Evaluation of plate type fuel elements by eddy current test method

    International Nuclear Information System (INIS)

    Frade, Rangel Teixeira

    2015-01-01

    Plate type fuel elements are used in MTR research nuclear reactors. The fuel plates are manufactured by assembling a briquette containing the fissile material inserted in a frame, with metal plates in both sides of the set, to act as a cladding. This set is rolled under controlled conditions in order to obtain the fuel plate. In Brazil, this type of fuel is manufactured by IPEN and used in the IEA-R1 reactor. After fabrication of three batches of fuel plates, 24 plates, one of them is taken, in order to verify the thickness of the cladding. For this purpose, the plate is sectioned and the thickness measurements are carried out by using optical microscopy. This procedure implies in damage of the plate, with the consequent cost. Besides, the process of sample preparation for optical microscopy analysis is time consuming, it is necessary an infrastructure for handling radioactive materials and there is a generation of radioactive residues during the process. The objective of this study was verify the applicability of eddy current test method for nondestructive measurement of cladding thickness in plate type nuclear fuels, enabling the inspection of all manufactured fuel plates. For this purpose, reference standards, representative of the cladding of the fuel plates, were manufactured using thermomechanical processing conditions similar to those used for plates manufacturing. Due to no availability of fuel plates for performing the experiments, the presence of the plate’s core was simulated using materials with different electrical conductivities, fixed to the thickness reference standards. Probes of eddy current testing were designed and manufactured. They showed high sensitivity to thickness variations, being able to separate small thickness changes. The sensitivity was higher in tests performed on the reference standards and samples without the presence of the materials simulating the core. For examination of the cladding with influence of materials simulating the

  15. Osteosynthesis of ununited femoral neck fracture by internal fixation combined with iliac crest bone chips and muscle pedicle bone grafting

    Directory of Open Access Journals (Sweden)

    D D Baksi

    2016-01-01

    Full Text Available Background: Ununited femoral neck fracture is seen commonly in developing countries due to delayed presentation or failure of primary internal fixation. Such fractures, commonly present with partial or total absorption of femoral neck, osteonecrosis of femoral head in 8-30% cases with upward migration of trochanter posing problem for osteosynthesis, especially in younger individuals. Several techniques for treatment of such conditions are described like osteotomies or nonvascularied cortical or cancellous bone grafting provided varying degrees of success in terms of fracture union but unsatisfactory long term results occurred due to varying incidence of avascular necrosis (AVN of femoral head. Moreover, in presence of AVN of femoral head neither free fibular graft nor cancellous bone graft is satisfactory. The vascularied bone grafting by deep circumflex iliac artery based on iliac crest bone grafting, free vascularied fibular grafting and muscle pedicle periosteal grafting showed high incidence of success rate. Osteosynthesis is the preferred treatment of choice in ununited femoral neck fracture in younger individuals. Materials and Methods: Of the 293 patients operated during the period from June 1977 to June 2009, 42 were lost to followup. Seven patients with gluteus medius muscle pedicle bone grafting (MPBG were excluded. Thus, out of 244 patients, 208 (85.3% untreated nonunion and 36 (14.7% following failure of primary internal fixation were available for studies. Time interval between the date of injury and operation in untreated nonunion cases was mean 6.5 months and in failed internal fixation cases was mean 11.2 months. Ages of the patients varied from 16 to 55 years. Seventy patients had partial and 174 had subtotal absorption of the femoral neck. Evidence of avascular necrosis (AVN femoral head was found histologically in 135 (54.3% and radiologically in 48 (19.7% patients. The patients were operated by open reduction of fracture

  16. Aerodynamics of a translating comb-like plate inspired by a fairyfly wing

    Science.gov (United States)

    Lee, Seung Hun; Kim, Daegyoum

    2017-08-01

    Unlike the smooth wings of common insects or birds, micro-scale insects such as the fairyfly have a distinctive wing geometry, comprising a frame with several bristles. Motivated by this peculiar wing geometry, we experimentally investigated the flow structure of a translating comb-like wing for a wide range of gap size, angle of attack, and Reynolds number, Re = O(10) - O(103), and the correlation of these parameters with aerodynamic performance. The flow structures of a smooth plate without a gap and a comb-like plate are significantly different at high Reynolds number, while little difference was observed at the low Reynolds number of O(10). At low Reynolds number, shear layers that were generated at the edges of the tooth of the comb-like plate strongly diffuse and eventually block a gap. This gap blockage increases the effective surface area of the plate and alters the formation of leading-edge and trailing-edge vortices. As a result, the comb-like plate generates larger aerodynamic force per unit area than the smooth plate. In addition to a quasi-steady phase after the comb-like plate travels several chords, we also studied a starting phase of the shear layer development when the comb-like plate begins to translate from rest. While a plate with small gap size can generate aerodynamic force at the starting phase as effectively as at the quasi-steady phase, the aerodynamic force drops noticeably for a plate with a large gap because the diffusion of the developing shear layers is not enough to block the gap.

  17. Chest-wall reconstruction in case of infection of the operative site: is there any interest in titanium rib osteosynthesis?

    Science.gov (United States)

    Berthet, Jean-Philippe; Solovei, Laurence; Tiffet, Olivier; Gomez-Caro, Abel; Bommart, Sébastien; Canaud, Ludovic; Alric, Pierre; Marty-Ané, Charles-Henri

    2013-11-01

    To describe the management of thoracic reconstructions in the presence of primary chest-wall infection (PCWI) or secondary deep chest-wall infection (SCWI), focussing on local tolerance of a titanium rib osteosynthesis system. PCWI included infected chest wall tumours (CWT), infected T3 non-small-cell lung carcinoma (NSCLC) and open flail chest. SCWI was defined by deep infection of previous thoracic-wall reconstructions. Infection was identified by preoperative bacterial analysis of the tumour or surgical site. In PCWI, a one-step procedure combined extensive resection of infected tissues and rigid reconstruction of the defect; skeletal rigidity was achieved using titanium implants. In SCWI, we removed all synthetic material except titanium implants. In both groups, the surgical field was thoroughly cleaned and implants were wrapped or covered by flaps. From January 2005 to December 2011, 11 patients (54 ± 10.2 years) with either PCWI (3 CWT, 3 T3 NSCLC, 1 open flail chest) or SCWI (3 CWT, 1 funnel chest) were treated. Infection was polymicrobial in all but 1 case. Bacteria observed in PCWI patients were multidrug resistant. In PCWI, we resected 4.2 ± 0.6 ribs en bloc with the lung (n = 5), the skin and the pectoralis major and then used mesh and 2.1 ± 1.2 titanium implants for reconstruction (n = 6). The mean defect was 1154.4 ± 318 cm(3). Surgical SCWI management removed polytetrafluoroethylene-mesh and preserved the titanium implants. A Vicryl mesh (n = 3) and greater omentum flap (n = 3) were added. One of the 2 postoperative deaths in the PCWI group was related to infection recurrence. No other patient had infection at the 6-month follow-up with leucocyte-labelled scintigraphy. Titanium rib osteosynthesis is reliable in two complex and life-threatening situations: PCWIs and SCWIs. In combination with a flap, this allows rapid, reliable, rigid reconstruction of infected full-thickness chest-wall defects in a single-step procedure.

  18. Surgical treatment of chronic mandibular dislocation--report of a case.

    Science.gov (United States)

    Bakardjiev, Angel G; Atanasov, Dimitar T

    2002-01-01

    Chronic dislocation of the temporomandibular jaw (TMJ) can result from lax joint ligaments and parafunctioning joints; it can also be a consequence of a systemic connective tissue disorder. The authors report a case of hypermobile joint syndrome in combination with mitral valve prolapse. The case was managed by osteosynthesis using modified titanium plate.

  19. The HARP resistive plate chambers: Characteristics and physics performance

    International Nuclear Information System (INIS)

    Ammosov, V.; Boyko, I.; Chelkov, G.; Dedovitch, D.; Dumps, R.; Dydak, F.; Elagin, A.; Gapienko, V.; Gostkin, M.; Guskov, A.; Kroumchtein, Z.; Koreshev, V.; Linssen, L.; Nefedov, Yu.; Nikolaev, K.; Semak, A.; Sviridov, Yu.; Usenko, E.; Wotschack, J.; Zaets, V.; Zhemchugov, A.

    2007-01-01

    The HARP Resistive Plate Chamber (RPC) system was designed for time-of-flight measurement in the large-angle acceptance region of the HARP spectrometer. It comprised 46 four-gap glass RPCs covering an area of ∼8m 2 . The design of the RPCs, their operation, intrinsic properties, and system performance are described. The intrinsic time resolution of the RPCs is better than 130ps leading to a system time resolution of ∼175ps

  20. Simulation on a limited angle beam gamma ray tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Bum; Jung, Sung Hee; Moon, Jin Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-10-15

    Limited angle beam tomography was introduced in the medical field more than two decades ago, where it was mainly used for cardiovascular diagnostics. Later, it was also used to trace multiphase flows. In these studies, the detection systems were fixed and a scanning electron beam was rapidly swept across an xray target using deflection coils. Thus very fast scanning was possible in these studies, but their geometry resulted in a heavy and bulky system because of a complex control system and vacuum tube. Because of its heavy hardware, limited angle beam tomography has remained as indoor equipment. If the source section is replaced by a gamma ray source, limited angle beam tomography will have a very light source device. In addition, limited angle beam tomography with a gamma ray source can be designed using an open type portable gantry because it does not need a vacuum guide for an electron beam. There is a lot of need for a portable tomographic system but so far no definitive solution has been created. The inspection of industrial on-line pipes, wood telephone poles, and cultural assets are some application areas. This study introduces limited angle beam gamma ray tomography, its simulation, and image reconstruction results. Image reconstruction was performed on the virtual experimental data from a Monte Carlo simulation. Image reconstruction algorithms that are known to be useful for limited angle data were applied and their results compared

  1. Effect of geometric and process variables on the performance of inclined plate settlers in treating aquacultural waste.

    Science.gov (United States)

    Sarkar, Sudipto; Kamilya, Dibyendu; Mal, B C

    2007-03-01

    Inclined plate settlers are used in treating wastewater due to their low space requirement and high removal rates. The prediction of sedimentation efficiency of these settlers is essential for their performance evaluation. In the present study, the technique of dimensional analysis was applied to predict the sedimentation efficiency of these inclined plate settlers. The effect of various geometric parameters namely, distance between plates (w(p)), plate angle (alpha), length of plate (l(p)), plate roughness (epsilon(p)), number of plates (n(p)) and particle diameter (d(s)) on the dynamic conditions, influencing the sedimentation process was studied. From the study it was established that neither the Reynolds criterion nor the Froude criterion was singularly valid to simulate the sedimentation efficiency (E) for different values of w(p) and flow velocity (v(f)). Considering the prevalent scale effect, simulation equations were developed to predict E at different dynamic conditions. The optimum dynamic condition producing the maximum E is also discussed.

  2. Refraction angle and edge visibility in X-ray diffraction enhanced imaging

    International Nuclear Information System (INIS)

    Chen Yu; Jia Quanjie; Li Gang; Wang Yuzhu; Xue Xianying; Jiang Xiaoming

    2007-01-01

    Diffraction-enhanced X-ray imaging could extract accurately the refraction angles of the sample, which is very important to increase the image contrast of low Z samples. In this paper, the DEI experiments with X-rays of different energies were performed both on wedge-shaped and rounded model samples. Refraction angles of the two samples were all obtained accurately, and the results agreed well with the calculations. Quantitative analyses based on Edge Visibility were performed for the wedge-shaped model sample. The results revealed that the calculated positions for the Best Edge Visibility of the slope with fixed refraction angle were calculable in good agreement with the experimental results. A quantitative research on the Edge Visibility of real tissues sample was carried out and the optimal condition for best contrast of DEI images were discussed. (authors)

  3. A study on the variation of maxillary sinus volume and projection angle in children for CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Youn Sang; Dong, Kyung Rae; Choi, Seong Kwan; Kim, Mi Hyun [Radiological Technology, Gwangju Health University, Gwangju (Korea, Republic of); Jung, Myung Jin [Dept. of Radiation Science and Technology, Graduate School of Chonbuk National University, Jeonju (Korea, Republic of); Yeo, Hwa Yeon [Dept. of Radiology, Nambu University, Gwangju (Korea, Republic of)

    2017-06-15

    The Water's view is that you can examine and diagnose disease of the maxillary sinus and implemented a simple and economical because a lot of tests. Because changes in the size of the maxillary sinus and skull growth in volume, depending on the disease that occurs in children often differ from the baseline angle of the water's view that it is easy to observe. Through Computed tomography (CT) and volumetric analysis and Orbitmeatal line (OML) and Image plate (IP) is the angle and evaluate the appropriate Water's view angle in children.

  4. Graft fixation with predetermined tension using a new device, the double spike plate.

    Science.gov (United States)

    Shino, Konsei; Mae, Tatsuo; Maeda, Akira; Miyama, Takahide; Shinjo, Hirotaka; Kawakami, Hideo

    2002-10-01

    To biomechanically evaluate a new fixation device, DSP (Double Spike Plate; Meira Corp, Nagoya, Aichi, Japan), for pullout graft fixation. Biomechanical study. A porcine tibia in which 8-mm diameter drill holes had been made from the medial tibial metaphysis to the anterior cruciate ligament attachment was rigidly fixed to a tension analyzer. A quadrupled graft consisting of 2 double-looped bovine tendons was prepared with No. 3 polyester sutures placed distally. The graft was passed through the drill hole, and its proximal loop ends were rigidly fixed to a load cell for monitoring graft tension. The graft's distal ends were connected to the DSP by tying the sutures to the top hole in the DSP. The graft tension was predetermined at 49 N (n = 5) or 98 N (n = 5). This tension was maintained for 5 minutes with a suture passed through the bottom hole of the DSP. The plate was fixed to the tibia by hammering its spikes into the bone under the index tension. Finally, the fixation was completed by inserting a screw. Although the graft tension immediately increased to 69 +/- 11 N or 133 +/- 14 N during hammering, it gradually reduced to 49 +/- 10 N or 100 +/- 7 N 5 minutes later. This study shows that graft fixation under a predetermined tension can be achieved with the DSP.

  5. Tensile Test of Welding Joint Parts for a Plate-type Fuel Assembly

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, K. H.; Kim, J. Y.; Kim, H. J.; Yim, J. S. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    The tensile tests were performed using an INSTRON 4505 (universal tensile) testing machine. These welding joints are composed of two parts for the soundness of the fuel assembly; one is the side plate with a fixing bar and the other is a side plate with an end fitting. These two joint parts are fabricated by TIG welding method. The tensile tests of the welding joints of a plate-type FA are executed by a tensile test. The fixture configurations for the specimen are very important to obtain the strict test results. The maximum strength has an approximately linear correlation with the unit bonding length of the welding joints. In spite of these results, the maximum strengths of the welding joints are satisfied according to the minimum requirement. These tensile tests of the joint parts for a plate-type fuel assembly (FA) have to be executed to evaluate the structural strength. For the tensile test, the joint parts of a FA used in the test are made of aluminum alloy (Al6061-T6)

  6. Tensile Test of Welding Joint Parts for a Plate-type Fuel Assembly

    International Nuclear Information System (INIS)

    Yoon, K. H.; Kim, J. Y.; Kim, H. J.; Yim, J. S.

    2013-01-01

    The tensile tests were performed using an INSTRON 4505 (universal tensile) testing machine. These welding joints are composed of two parts for the soundness of the fuel assembly; one is the side plate with a fixing bar and the other is a side plate with an end fitting. These two joint parts are fabricated by TIG welding method. The tensile tests of the welding joints of a plate-type FA are executed by a tensile test. The fixture configurations for the specimen are very important to obtain the strict test results. The maximum strength has an approximately linear correlation with the unit bonding length of the welding joints. In spite of these results, the maximum strengths of the welding joints are satisfied according to the minimum requirement. These tensile tests of the joint parts for a plate-type fuel assembly (FA) have to be executed to evaluate the structural strength. For the tensile test, the joint parts of a FA used in the test are made of aluminum alloy (Al6061-T6)

  7. A highly accurate dynamic contact angle algorithm for drops on inclined surface based on ellipse-fitting.

    Science.gov (United States)

    Xu, Z N; Wang, S Y

    2015-02-01

    To improve the accuracy in the calculation of dynamic contact angle for drops on the inclined surface, a significant number of numerical drop profiles on the inclined surface with different inclination angles, drop volumes, and contact angles are generated based on the finite difference method, a least-squares ellipse-fitting algorithm is used to calculate the dynamic contact angle. The influences of the above three factors are systematically investigated. The results reveal that the dynamic contact angle errors, including the errors of the left and right contact angles, evaluated by the ellipse-fitting algorithm tend to increase with inclination angle/drop volume/contact angle. If the drop volume and the solid substrate are fixed, the errors of the left and right contact angles increase with inclination angle. After performing a tremendous amount of computation, the critical dimensionless drop volumes corresponding to the critical contact angle error are obtained. Based on the values of the critical volumes, a highly accurate dynamic contact angle algorithm is proposed and fully validated. Within nearly the whole hydrophobicity range, it can decrease the dynamic contact angle error in the inclined plane method to less than a certain value even for different types of liquids.

  8. Differences in Tribological Behaviors upon Switching Fixed and Moving Materials of Tribo-pairs including Metal and Polymer.

    Science.gov (United States)

    Xu, Aijie; Tian, Pengyi; Wen, Shizhu; Guo, Fei; Hu, Yueqiang; Jia, Wenpeng; Dong, Conglin; Tian, Yu

    2017-10-12

    The coefficient of friction (COF) between two materials is usually believed to be an intrinsic property of the materials themselves. In this study, metals of stainless steel (304) and brass (H62), and polymers of polypropylene (PP) and polytetrafluoroethylene (PTFE) were tested on a standard ball-on-three-plates test machine. Significantly different tribological behaviors were observed when fixed and moving materials of tribo-pairs (metal/polymer) were switched. As an example, under the same applied load and rotating speed, the COF (0.49) between a rotating PP ball and three fixed H62 plates was approximately 2.3 times higher than that between switched materials of tribo-pairs. Meanwhile, the COF between H62 and PTFE was relatively stable. The unexpected tribological behaviors were ascribed to the thermal and mechanical properties of tribo-pairs. Theoretical analysis revealed that the differences in the maximum local temperature between switching the fixed and moving materials of tribo-pairs were consistent with the differences in the tested COF. This result indicated the precise prediction of the COF of two materials is complexcity, and that thermal and mechanical properties should be properly considered in designing tribo-pairs, because these properties may significantly affect tribological performance.

  9. African Plate Seismicity and Gravity Field Anomalies

    Science.gov (United States)

    Ryzhii, B. P.; Nachapkin, N. I.; Milanovsky, Svet

    The analysis of connection plate of earthquakes of the African continent with Bouguer gravity anomalies is carried out. As input dataSs were used the catalog of earthquakes and numeral map of Bouguer gravity field. The catalog contains geographical coor- dinates of epicenters and magnitudes of 8027 earthquakes recorded on continent and adjacent oceanic areas for the period from 1904 to 1988 years. The values of a gravity field preset in knots of a grid with a step 1 grade. For the analysis of plate seismicity from the catalog the parameters of 6408 earthquakes were chosen, which one have taken place in the field of restricted shore line. The earthquakes fixed in a band of a concatenation of continent with the Arabian plate were excluded from the analysis. On the basis of a numeral gravity map for everyone epicenter the value of Bouguer anomaly was calculated. The allocation of epicenters of earthquakes with magnitude M is obtained depending on value of a gravity Bouguer field. The outcomes of a sta- tistical analysis testify that practically all earthquakes are associated with the areas with negative values of Bouguer gravity field. Thus in areas with values of a field -160 mgal to -100 mgal there was 80 % of all earthquakes. It is necessary to note, that the mean value of the field for the African continent is -70 mgal. Obtained result gives us the possibility to make a conclusion about connection of plate earthquakes of Africa predominantly with structural complexes of earth crust with lower density. These out- comes are in the consent with a hypothesis of one of the authors (Ryzhii B.P.) about connection of plate earthquakes hypocenters on the territory of Russia with negative values of a gravity field and heightened silica content in the Earth crust. This work was supported with RFFI grant N 00-05-65067

  10. End plates made of a composite material for the revolving drum of a centrifuge

    International Nuclear Information System (INIS)

    Yamanaka, T.; Onishi, H.; Fujiwara, M.

    1980-01-01

    The present invention relates to improvement of the end plates of centrifuges, especially those for centrifugal gas separators. End plates made of a composite material for the revolving drum of a centrifuge consists of a carbon-fiber-reinforced plastic layer. This layer consists of carbon fibers either wound helically at an angle greater than 75 0 and less than 90 0 to the center line of revolution, or wound in a hoop, and a matrix of a thermosetting resin in which the carbon fibers are buried, which [matrix] is laminated with metal layers

  11. Hydrodynamics of a flexible plate between pitching rigid plates

    Science.gov (United States)

    Kim, Junyoung; Kim, Daegyoum

    2017-11-01

    The dynamics of a flexible plate have been studied as a model problem in swimming and flying of animals and fluid-structure interaction of plants and flags. Motivated by fish schooling and an array of sea grasses, we investigate the dynamics of a flexible plate closely placed between two pitching rigid plates. In most studies on passive deformation of the flexible plate, the plate is immersed in a uniform flow or a wavy flow. However, in this study, the flexible plate experiences periodic deformation by the oscillatory flow generated by the prescribed pitching motion of the rigid plates. In our model, the pitching axes of the rigid plates and the clamping position of the flexible plate are aligned on the same line. The flexible plate shows various responses depending on length and pitching frequency of rigid plates, thickness of a flexible plate, and free-stream velocity. To find the effect of each variable on the response of the flexible plate, amplitude of a trailing edge and modal contribution of a flapping motion are compared, and flow structure around the flexible plate is examined.

  12. Design and fabrication of a self-aligned parallel-plate-type silicon micromirror minimizing the effect of misalignment

    International Nuclear Information System (INIS)

    Yoo, Byung-Wook; Jin, Joo-Young; Jang, Yun-Ho; Kim, Yong-Kweon; Park, Jae-Hyoung

    2009-01-01

    This paper describes a self-alignment method whereby a mirror actuation voltage, corresponding to a specific tilting angle, is unvarying in terms of misalignment during fabrication. A deep silicon etching process is proposed to penetrate the top silicon layer (the micromirror layer) and an amorphous silicon layer (the addressing electrode layer) together, through an aluminum mask pattern, in order to minimize the misalignment effect on the micromirror actuation. The size of a fabricated mirror plate is 250 × 250 × 4 µm 3 . A pair of amorphous silicon electrodes under the mirror plate is about half the size of the mirror plate individually. Numerical analysis associated with calculating the pull-in voltage and the bonding misalignment is performed to verify the self-alignment concepts focused upon in this paper. Curves of the applied voltage versus the tilt angle of the self-aligned micromirror are observed using a position sensing detector in order to compare the measurement results with MATLAB analysis of the expected static deflections. Although a 3.7 µm misalignment is found between the mirror plate and the electrodes, in the direction perpendicular to the shallow trench of the electrodes, before the self-alignment process, the measured pull-in voltage has been found to be 103.4 V on average; this differs from the pull-in voltage of a perfectly aligned micromirror by only 0.67%. Regardless of the unpredictable misalignments in repetitive photolithography and bonding, the tilting angles corresponding to the driving voltages are proved to be uniform along the single axis as well as conform to the results of analytical analysis

  13. Flow over a cylinder with a hinged-splitter plate

    Science.gov (United States)

    Shukla, S.; Govardhan, R. N.; Arakeri, J. H.

    2009-05-01

    regime, the spectra of the oscillations become broadband, and are reminiscent of the change in character of the wake oscillations seen in the earlier fixed-rigid splitter plate case for L/D⩾5.0. In the present case of the hinged-splitter plate, the sudden transition seen as the splitter plate length (L/D) is increased from 3 to 4 may be attributed to the fact that the wake vortices are no longer able to synchronize with the plate motions for larger splitter plate lengths. Hence, as observed in other vortex-induced vibration problems, the oscillations become aperiodic and the amplitude reduces dramatically.

  14. Efficacy and tolerability of fixed-combination bimatoprost/timolol versus fixed-combination dorzolamide/brimonidine/timolol in patients with primary open-angle glaucoma or ocular hypertension: a multicenter, prospective, crossover study.

    Science.gov (United States)

    García-López, Alfonso; Paczka, José A; Jiménez-Román, Jesús; Hartleben, Curt

    2014-12-19

    Fixed-combination ocular hypotensives have multiple advantages, but triple-therapy dorzolamide/brimonidine/timolol (dorz/brim/tim) is only available in Latin and South America, and information on its relative efficacy is limited. This study compares the efficacy and tolerability of fixed-combination bimatoprost/timolol (bim/tim) and dorz/brim/tim in Mexican patients with primary open-angle glaucoma or ocular hypertension. In this investigator-masked, crossover study, patients with unmet target intraocular pressure (IOP) on once-daily bim/tim or twice-daily dorz/brim/tim received the opposite medication for 3 months before returning to their pre-baseline medication for 3 months. IOP was evaluated before and after morning instillation at months 2, 3, 5 and 6. Primary endpoints were mean IOP change and Ocular Surface Disease Index© (OSDI) score at each visit. The intent-to-treat population was the a priori analysis population, but due to the number of discontinuations, the per-protocol and intent-to-treat populations were used for the primary efficacy and sensitivity analyses, respectively. Seventy-eight and 56 patients were included in the intent-to-treat and per-protocol populations, respectively. At month 3, statistically significant IOP reductions from baseline were observed in the bim/tim (P < 0.01) and dorz/brim/tim (P < 0.0001) groups, regardless of assessment time. At month 6, patients returned to bim/tim exhibited no significant IOP increase (regardless of assessment time), but patients returned to dorz/brim/tim exhibited a statistically significant IOP increase (P < 0.001) when assessed before instillation of study treatment. Results were similar in both intent-to-treat and per-protocol analysis populations. In the per-protocol analysis, 70% of patients on bim/tim at month 3 had an IOP <14 mm Hg, which declined to 58% (P = 0.0061) at month 6 (ie, after 3 months of dorz/brim/tim treatment). In patients receiving dorz/brim/tim at month 3

  15. Contact angle and surface tension measurements of a five-ring polyphenyl ether

    Science.gov (United States)

    Jones, W. R., Jr.

    1986-01-01

    Contact angle measurements were performed for a five-ring polyphenyl ether isomeric mixture on M-50 steel in a dry nitrogen atmosphere. Two different techniques were used: (1) a tilting plate apparatus, and (2) a sessile drop apparatus. Measurements were made for the temperature range 25 to 190 C. Surface tension was measured by a differential maximum bubble pressure technique over the range 23 to 220 C in room air. The critical surface energy of spreading (gamma /sub c/) was determined for the polyphenyl ether by plotting the cosine of the contact angle (theta) versus the surface tension (gamma /sub LV/). The straight line intercept at cosine theta = 1 is defined as gamma (sub c). Gamma (sub c) was found to be 30.1 dyn/cm for the tilting plate technique and 31.3 dyn/cm for the sessile drop technique. These results indicate that the polyphenyl ether is inherently autophobic (i.e., it will not spread on its own surface film until its surface tension is less than gamma /sub c/). This phenomenon is discussed in light of the wettability and wear problems encountered with this fluid.

  16. Assessment of Optimum Value for Dip Angle and Locking Rate Parameters in Makran Subduction Zone

    Science.gov (United States)

    Safari, A.; Abolghasem, A. M.; Abedini, N.; Mousavi, Z.

    2017-09-01

    Makran subduction zone is one of the convergent areas that have been studied by spatial geodesy. Makran zone is located in the South Eastern of Iran and South of Pakistan forming the part of Eurasian-Arabian plate's border where oceanic crust in the Arabian plate (or in Oman Sea) subducts under the Eurasian plate ( Farhoudi and Karig, 1977). Due to lack of historical and modern tools in the area, a sampling of sparse measurements of the permanent GPS stations and temporary stations (campaign) has been conducted in the past decade. Makran subduction zone from different perspectives has unusual behaviour: For example, the Eastern and Western parts of the region have very different seismicity and also dip angle of subducted plate is in about 2 to 8 degrees that this value due to the dip angle in other subduction zone is very low. In this study, we want to find the best possible value for parameters that differs Makran subduction zone from other subduction zones. Rigid block modelling method was used to determine these parameters. From the velocity vectors calculated from GPS observations in this area, block model is formed. These observations are obtained from GPS stations that a number of them are located in South Eastern Iran and South Western Pakistan and a station located in North Eastern Oman. According to previous studies in which the locking depth of Makran subduction zone is 38km (Frohling, 2016), in the preparation of this model, parameter value of at least 38 km is considered. With this function, the amount of 2 degree value is the best value for dip angle but for the locking rate there is not any specified amount. Because the proposed model is not sensitive to this parameter. So we can not expect big earthquakes in West of Makran or a low seismicity activity in there but the proposed model definitely shows the Makran subduction layer is locked.

  17. Oblique Wave-Induced Responses of A VLFS Edged with A Pair of Inclined Perforated Plates

    Science.gov (United States)

    Cheng, Yong; Ji, Chun-yan; Zhai, Gang-jun; Oleg, Gaidai

    2018-03-01

    This paper is concerned with the hydroelastic responses of a mat-like, rectangular very large floating structure (VLFS) edged with a pair of horizontal/inclined perforated anti-motion plates in the context of the direct coupling method. The updated Lagrangian formulae are applied to establish the equilibrium equations of the VLFS and the total potential formula is employed for fluids in the numerical model including the viscous effect of the perforated plates through the Darcy's law. The hybrid finite element-boundary element (FE-BE) method is implemented to determine the response reduction of VLFS with attached perforated plates under various oblique incident waves. Also, the numerical solutions are validated against a series of experimental tests. The effectiveness of the attached perforated plates in reducing the deflections of the VLFS can be significantly improved by selecting the proper design parameters such as the porous parameter, submergence depth, plate width and inclination angle for the given sea conditions.

  18. Vibration reduction of composite plates by piezoelectric patches using a modified artificial bee colony algorithm

    Directory of Open Access Journals (Sweden)

    Hadi Ghashochi-Bargh

    Full Text Available In Current paper, power consumption and vertical displacement optimization of composite plates subject to a step load are carried out by piezoelectric patches using the modified multi-objective Elitist-Artificial Bee Colony (E-ABC algorithm. The motivation behind this concept is to well balance the exploration and exploitation capability for attaining better convergence to the optimum. In order to reduce the calculation time, the elitist strategy is also used in Artificial Bee Colony algorithm. The voltages of patches, plate length/width ratios, ply angles, plate thickness/length ratios, number of layers and edge conditions are chosen as design variables. The formulation is based on the classical laminated plate theory (CLPT and Hamilton's principle. The performance of the new ABC approach is compared with the PSO algorithm and shows the good efficiency of the new ABC approach. To check the validity, the transient responses of isotropic and orthotropic plates are compared with those available in the literature and show a good agreement.

  19. Global Dynamic Numerical Simulations of Plate Tectonic Reorganizations

    Science.gov (United States)

    Morra, G.; Quevedo, L.; Butterworth, N.; Matthews, K. J.; Müller, D.

    2010-12-01

    We use a new numerical approach for global geodynamics to investigate the origin of present global plate motion and to identify the causes of the last two global tectonic reorganizations occurred about 50 and 100 million years ago (Ma) [1]. While the 50 Ma event is the most well-known global plate-mantle event, expressed by the bend in the Hawaiian-Emperor volcanic chain, a prominent plate reorganization at about 100 Ma, although presently little studied, is clearly indicated by a major bend in the fracture zones in the Indian Ocean and by a change in Pacific plate motion [2]. Our workflow involves turning plate reconstructions into surface meshes that are subsequently employed as initial conditions for global Boundary Element numerical models. The tectonic setting that anticipates the reorganizations is processed with the software GPlates, combining the 3D mesh of the paleo-plate morphology and the reconstruction of paleo-subducted slabs, elaborated from tectonic history [3]. All our models involve the entire planetary system, are fully dynamic, have free surface, are characterized by a spectacular computational speed due to the simultaneous use of the multi-pole algorithm and the Boundary Element formulation and are limited only by the use of sharp material property variations [4]. We employ this new tool to unravel the causes of plate tectonic reorganizations, producing and comparing global plate motion with the reconstructed ones. References: [1] Torsvik, T., Müller, R.D., Van der Voo, R., Steinberger, B., and Gaina, C., 2008, Global Plate Motion Frames: Toward a unified model: Reviews in Geophysics, VOL. 46, RG3004, 44 PP., 2008 [2] Wessel, P. and Kroenke, L.W. Pacific absolute plate motion since 145 Ma: An assessment of the fixed hot spot hypothesis. Journal of Geophysical Research, Vol 113, B06101, 2008 [3] L. Quevedo, G. Morra, R. D. Mueller. Parallel Fast Multipole Boundary Element Method for Crustal Dynamics, Proceeding 9th World Congress and 4th Asian

  20. Filling Open Screw Holes in the Area of Metaphyseal Comminution Does Not Affect Fatigue Life of the Synthes Variable Angle Distal Femoral Locking Plate in the AO/OTA 33-A3 Fracture Model.

    Science.gov (United States)

    Grau, Luis; Collon, Kevin; Alhandi, Ali; Kaimrajh, David; Varon, Maria; Latta, Loren; Vilella, Fernando

    2018-06-01

    The aim of this study is to evaluate the biomechanical effect of filling locking variable angle (VA) screw holes at the area of metaphyseal fracture comminution in a Sawbones® (Sawbones USA, Vashon, Washington) model (AO/OTA 33A-3 fracture) using a Synthes VA locking compression plate (LCP) (Depuy Synthes, Warsaw, Indiana). Seven Sawbones® femur models had a Synthes VA-LCP placed as indicated by the manufacturers technique. A 4cm osteotomy was then created to simulate an AO/OTA 33-A3 femoral fracture pattern with metaphyseal comminution. The control group consisted of four constructs in which the open screw holes at the area of comminution were left unfilled; the experimental group consisted of three constructs in which the VA screw holes were filled with locking screws. One of the control constructs was statically loaded to failure at a rate of 5mm/min. A value equal to 75% of the ultimate load to failure was used as the loading force for fatigue testing of 250,000 cycles at 3Hz. Cycles to failure was recorded for each construct and averages were compared between groups. The average number of cycles to failure in the control and experimental groups were 37524±8187 and 43304±23835, respectively (p=0.72). No significant difference was observed with respect to cycles to failure or mechanism of failure between groups. In all constructs in both the control and experimental groups, plate failure reproducibly occurred with cracks through the variable angle holes in the area of bridged comminution. The Synthes VA-LCP in a simulated AO/OTA 33-A3 comminuted metaphyseal femoral fracture fails in a reproducible manner at the area of comminution through the "honeycomb" VA screw holes. Filling open VA screw holes at the site of comminution with locking screws does not increase fatigue life of the Synthes VA-LCP in a simulated AO/OTA 33-A3 distal femoral fracture. Further studies are necessary to determine whether use of this particular plate is contraindicated when bridging

  1. A mechanism of thrust enhancement on a heaving plate due to flexibility at moderately low Reynolds numbers

    Science.gov (United States)

    Lin, Yung-Sheng; Tzeng, Yau-Ting; Chang, Chien-Cheng; Chu, Chin-Chou

    2017-11-01

    A numerical study is conducted to investigate the force mechanisms for a 3D heaving flexible plate from the perspective of a diagnostic force element analysis (Chang 1992). The problem is relevant to a simplified flapping fish-tail with the front edge held fixed in space. The flow is assumed to be laminar with the Reynolds numbers fixed at Re =200 or 500, and the Strouhal number St ranging from 0.1 to 0.6, and the flexure amplitude of the plate a0 for 0.1 to 0.25 (dimensionless). It is shown that heaving, whilst increasing thrust generation, also reduces the frictional drag, yet the flexibility promotes thrust generation at the expense of accruing more frictional drag. In the literature, the thrust exerted on the tail-mimicking plate is largely credited to the vortices in the wake. However, this study performs a regional force analysis to show that the vorticity in the wake region supplies approximately 20-30% of the total thrust, especially in the cases of strong thrust generation. Comparable contributions come also from the regions direct above and below the heaving plate (mainly including the attached vortices) as well as from the two side regions (mainly including the tip vortices) next to the flapping plate. In addition, the potential motion associated with the unsteady flapping and the contribution from the surface vorticity are non-negligible constituent force components. MOST, TAIWAN under Contacts NO. 105-2221-E-002-097-MY3 and NO. 105-2221-E-002 -105 -MY3.

  2. Static and Monoharmonic Acoustic Impact on a Laminated Plate

    Science.gov (United States)

    Paimushin, V. N.; Gazizullin, R. K.

    2017-07-01

    A discrete layered damping model of a multilayer plate at small displacements and deformations, with account of the internal damping of layers according to the Thompson-Kelvin-Voight model, is presented. Based on the equations derived, an analytical solution to the static deformation problem for single-layer rectangular plate hinge-supported along its contour and subjected of a uniformly distributed pressure applied to one of its boundary planes is obtained. Its convergence to the three-dimensional solution is analyzed in relation to the dimension of mesh in the thickness direction of the plate. It is found that, for thin plates, the dimension of the problem formulated can be reduced on the basis of simplified hypotheses applied to each layer. An analytical solutions is also constructed for the forced vibrations of two- and three-layer rectangular plates hinged in the opening of an absolutely stiff dividing wall upon transmission of a monoharmonic sound wave through them. It was assumed that the dividing wall is situated between two absolutely stiff barriers; one of them, owing to the harmonic vibration with a given displacement amplitude of the plate, forms an incident sound wave, and the other is stationary and is coated by a energy-absorbing material with high damping properties. Behavior of the acoustic media in spaces between the deformable plate and the barriers is described by the classical wave equations based on the model of an ideal compressible fluid. To describe the process of dynamic deformation of the energy-absorbing coating of the fixed barrier, two-dimensional equations of motion are derived based on the model of a transversely soft layer, a linear approximation of displacement fields in the thickness direction of the coating, and the account of damping properties of its material by using the hysteresis model. The effect of physical and mechanical parameters of the mechanical system considered and of frequency of the incident sound wave on the

  3. Fixed-combination treatments for intraocular hypertension in Chinese patients – focus on bimatoprost-timolol

    Directory of Open Access Journals (Sweden)

    Fang Y

    2015-05-01

    Full Text Available Yuan Fang,1,* Zhihong Ling,1,* Xinghuai Sun1–4 1Department of Ophthalmology and Visual Science, Eye, Ear, Nose and Throat Hospital, Shanghai Medical College, Fudan University, 2Shanghai Key Laboratory of Visual Impairment and Restoration, 3Key Laboratory of Myopia, Ministry of Health, 4State Key Laboratory of Medical Neurobiology, Institutes of Brain Science, Fudan University, Shanghai, People’s Republic of China *These authors contributed equally to this work Abstract: Glaucoma is a common eye disease that can lead to irreversible vision loss if left untreated. The early diagnosis and treatment of primary open-angle glaucoma is challenging, and visual impairment in Chinese glaucoma patients is a serious concern. Most of these patients need more than one topical antiglaucoma agent to control their intraocular pressures (IOPs. In the People’s Republic of China, the daily cost of different glaucoma medication varies greatly, and the treatment habits differ throughout the country. Prostaglandin analogs (PGAs are recommended as first-line monotherapy, because of their efficacy and low risk of systemic side effects. Fixed-combination drops, particularly PGA-based fixed combinations, have recently been developed and used in patients with progression or who have failed to achieve their target IOPs. Here, we reviewed the current literature on the use of bimatoprost-timolol fixed combination (BTFC in the People’s Republic of China. BTFC has achieved good efficacy and tolerability in Chinese clinical trials. In addition, BTFC is more cost effective compared with other fixed combinations available in the People’s Republic of China. Fixed-combination drops may offer benefits, such as keeping the ocular surface healthy, convenience of administration, and improvement in long-term adherence and quality of life. Therefore, BTFC has great potential for the treatment of Chinese glaucoma patients. However, the long-term efficacy of BTFC, comparisons

  4. Two-media boundary layer on a flat plate

    OpenAIRE

    Nikolay Ilyich Klyuev; Asgat Gatyatovich Gimadiev; Yuriy Alekseevich Kryukov

    2014-01-01

    The present paper provides a solution to the problem of a flow over a flat semi-infinite plate set at an angle to the horizon, and having a thin liquid film on its surface by external airflow. The film is formed by extrusion of liquid from the porous wall. The paper proposes a mathematical model of a two-media boundary layer flow. The main characteristics of the flow to a zero and a first approximation are determined. A drop of frictional stress is obtained.

  5. REPARATIVE OSTEOGENESIS DURING TREATMENT OF FRACTURE UNDER TRANSOSSEOUS OSTEOSYNTHESIS AND INTRAMEDULLARY INSERTION OF WIRES WITH HYDROXYAPATITE COATING

    Directory of Open Access Journals (Sweden)

    Iurii M. Irianov, Arnold V. Popkov, Nikolay A. Kiryanov, Tatiana Iu. Karaseva, Evgenii A. Karasev

    2015-04-01

    Full Text Available Background: The problem of improving medical care for patients with the locomotor system injuries is very important especially last time. Material and Methods: Canine open comminuted tibial fractures modelled experimentally, wires with hydroxyapatite coating inserted intramedullary, osteosynthesis performed with the Ilizarov fixator. Regenerated bones investigated 14-360 days after surgery using the techniques of light microscopy, scanning and transmission electron microscopy, and X-ray electron probe microanalysis for histologic sections . Results: It has been found that a zone of active reparative osteo- and angiogenesis forms around the wires, as well as a bone sheath with the properties of osteogenesis conductor and inductor. Fracture consolidation occurs early according to the primary type without cartilaginous and connective tissue formation in bone adhesion. Presented morphological characteristics endovasal angiogenesis. Conclusion: The results of the study evidence of the positive effect of intramedullary wires with hydroxyapatite coating on the course and intensity of reparative osteogenesis during fracture healing

  6. Angle-domain inverse scattering migration/inversion in isotropic media

    Science.gov (United States)

    Li, Wuqun; Mao, Weijian; Li, Xuelei; Ouyang, Wei; Liang, Quan

    2018-07-01

    The classical seismic asymptotic inversion can be transformed into a problem of inversion of generalized Radon transform (GRT). In such methods, the combined parameters are linearly attached to the scattered wave-field by Born approximation and recovered by applying an inverse GRT operator to the scattered wave-field data. Typical GRT-style true-amplitude inversion procedure contains an amplitude compensation process after the weighted migration via dividing an illumination associated matrix whose elements are integrals of scattering angles. It is intuitional to some extent that performs the generalized linear inversion and the inversion of GRT together by this process for direct inversion. However, it is imprecise to carry out such operation when the illumination at the image point is limited, which easily leads to the inaccuracy and instability of the matrix. This paper formulates the GRT true-amplitude inversion framework in an angle-domain version, which naturally degrades the external integral term related to the illumination in the conventional case. We solve the linearized integral equation for combined parameters of different fixed scattering angle values. With this step, we obtain high-quality angle-domain common-image gathers (CIGs) in the migration loop which provide correct amplitude-versus-angle (AVA) behavior and reasonable illumination range for subsurface image points. Then we deal with the over-determined problem to solve each parameter in the combination by a standard optimization operation. The angle-domain GRT inversion method keeps away from calculating the inaccurate and unstable illumination matrix. Compared with the conventional method, the angle-domain method can obtain more accurate amplitude information and wider amplitude-preserved range. Several model tests demonstrate the effectiveness and practicability.

  7. Plate waste of adults in the United States measured in free-living conditions.

    Directory of Open Access Journals (Sweden)

    Brian E Roe

    Full Text Available We analyze food-item level data collected from 50 adults from the United States using the Remote Food Photography Method® to provide the first estimates of plate waste gathered from adults across multiple consecutive meals and days in free-living conditions, and during laboratory-based meals with fixed food items and quantities. We find average plate waste in free-living conditions is 5.6 grams (7.7 kcals per item and that 3.3% of all food selected is returned as plate waste, where the percent waste figure is substantially lower than previously published plate waste estimates gathered primarily from dine-out settings in the United States such as buffets and institutional settings with limited-choice meals (e.g., school cafeterias. Plate waste from the same participants during the laboratory-based meals is significantly higher with an average of 203.2 grams of solid plate waste per meal (531.3 kcals or 39.1% of the food provided, which is similar to the plate waste percentages found reported in some school cafeteria settings. The amount of plate waste generated in free-living conditions is significantly positively associated with portion size selected for an item. In a multivariate analysis that controls for macronutrient profile, items selected from the vegetables, fats/oils/dressings, and grains categories are associated with significantly greater amounts of plate waste per item. We find no significant associations between free-living plate waste and gender, age, race or body mass index but find that women leave more plate waste in the lab meal where portion sizes are pre-determined by the researcher and similar for all respondents. We discuss possible implications of these findings for programs focused on reducing plate waste and food waste among consumers.

  8. Plate waste of adults in the United States measured in free-living conditions

    Science.gov (United States)

    Allen, H. Raymond

    2018-01-01

    We analyze food-item level data collected from 50 adults from the United States using the Remote Food Photography Method® to provide the first estimates of plate waste gathered from adults across multiple consecutive meals and days in free-living conditions, and during laboratory-based meals with fixed food items and quantities. We find average plate waste in free-living conditions is 5.6 grams (7.7 kcals) per item and that 3.3% of all food selected is returned as plate waste, where the percent waste figure is substantially lower than previously published plate waste estimates gathered primarily from dine-out settings in the United States such as buffets and institutional settings with limited-choice meals (e.g., school cafeterias). Plate waste from the same participants during the laboratory-based meals is significantly higher with an average of 203.2 grams of solid plate waste per meal (531.3 kcals) or 39.1% of the food provided, which is similar to the plate waste percentages found reported in some school cafeteria settings. The amount of plate waste generated in free-living conditions is significantly positively associated with portion size selected for an item. In a multivariate analysis that controls for macronutrient profile, items selected from the vegetables, fats/oils/dressings, and grains categories are associated with significantly greater amounts of plate waste per item. We find no significant associations between free-living plate waste and gender, age, race or body mass index but find that women leave more plate waste in the lab meal where portion sizes are pre-determined by the researcher and similar for all respondents. We discuss possible implications of these findings for programs focused on reducing plate waste and food waste among consumers. PMID:29444094

  9. Difference in metallic wear distribution released from commercially pure titanium compared with stainless steel plates.

    Science.gov (United States)

    Krischak, G D; Gebhard, F; Mohr, W; Krivan, V; Ignatius, A; Beck, A; Wachter, N J; Reuter, P; Arand, M; Kinzl, L; Claes, L E

    2004-03-01

    Stainless steel and commercially pure titanium are widely used materials in orthopedic implants. However, it is still being controversially discussed whether there are significant differences in tissue reaction and metallic release, which should result in a recommendation for preferred use in clinical practice. A comparative study was performed using 14 stainless steel and 8 commercially pure titanium plates retrieved after a 12-month implantation period. To avoid contamination of the tissue with the elements under investigation, surgical instruments made of zirconium dioxide were used. The tissue samples were analyzed histologically and by inductively coupled plasma atomic emission spectrometry (ICP-AES) for accumulation of the metals Fe, Cr, Mo, Ni, and Ti in the local tissues. Implant corrosion was determined by the use of scanning electron microscopy (SEM). With grades 2 or higher in 9 implants, steel plates revealed a higher extent of corrosion in the SEM compared with titanium, where only one implant showed corrosion grade 2. Metal uptake of all measured ions (Fe, Cr, Mo, Ni) was significantly increased after stainless steel implantation, whereas titanium revealed only high concentrations for Ti. For the two implant materials, a different distribution of the accumulated metals was found by histological examination. Whereas specimens after steel implantation revealed a diffuse siderosis of connective tissue cells, those after titanium exhibited occasionally a focal siderosis due to implantation-associated bleeding. Neither titanium- nor stainless steel-loaded tissues revealed any signs of foreign-body reaction. We conclude from the increased release of toxic, allergic, and potentially carcinogenic ions adjacent to stainless steel that commercially pure Ti should be treated as the preferred material for osteosyntheses if a removal of the implant is not intended. However, neither material provoked a foreign-body reaction in the local tissues, thus cpTi cannot be

  10. Magnetohydrodynamic flow of a rarefied gas near a time-varying accelerated plate

    International Nuclear Information System (INIS)

    Mishra, S.P.; Mohapatra, Priti

    1975-01-01

    The flow of an electrically conducting rarefied gas due to the time-varying motion of an infinite flat plate has been studied in the presence of a uniform magnetic field. The magnetic lines of force are taken to be fixed relative to the fluid. General expressions of the velocity and the skin friction have been compared by means of some qraphs and tables. (author)

  11. Sailplane Glide Performance and Control Using Fixed and Articulating Winglets. M.S. Thesis

    Science.gov (United States)

    Colling, James David

    1995-01-01

    An experimental study was conducted to investigate the effects of controllable articulating winglets on glide performance and yawing moments of high performance sailplanes. Testing was conducted in the Texas A&M University 7 x 10 foot Low Speed Wind Tunnel using a full-scale model of the outboard 5.6 feet of a 15 meter class high performance sailplane wing. Different wing tip configurations could be easily mounted to the wing model. A winglet was designed in which the cant and toe angles as well as a rudder on the winglet could be adjusted to a range of positions. Cant angles used in the investigation consisted of 5, 25, and 40 degrees measured from the vertical axis. Toe-out angles ranged from 0 to 22.5 degrees. A rudder on the winglet was used to study the effects of changing the camber of the winglet airfoil on wing performance and wing yawing moments. Rudder deflections consisted of-10, 0, and 10 degrees. Test results for a fixed geometry winglet and a standard wing tip are presented to show the general behavior of winglets on sailplane wings, and the effects of boundary-layer turbulators on the winglets are also presented. By tripping the laminar boundary-layer to turbulent before laminar separation occurs, the wing performance was increased at low Reynolds numbers. The effects on the lift and drag, yawing moment, pitching moment, and wing root bending moment of the model are presented. Oil flows were used on the wing model with the fixed geometry winglet and the standard wing tip to visualize flow directions and areas of boundary layer transition. A cant angle of 25 degrees and a toe-out angle of 2.5 degrees provided an optimal increase in wing performance for the cant and toe angles tested. Maximum performance was obtained when the winglet rudder remained in the neutral position of zero degrees. By varying the cant, toe, and rudder angles from their optimized positions, wing performance decreases. Although the winglet rudder proved to be more effective in

  12. Comparison of dorzolamide/timolol vs brinzolamide/brimonidine fixed combination therapy in the management of primary open-angle glaucoma.

    Science.gov (United States)

    Kozobolis, Vassileios; Panos, Georgios D; Konstantinidis, Aristeidis; Labiris, Georgios

    2017-03-10

    To compare the efficiency of brinzolamide/brimonidine fixed combination vs the dorzolamide/timolol fixed combination. Forty-four eyes of 44 patients were divided in 2 groups treated either with dorzolamide/timolol twice a day (group A) or with brinzolamide/brimonidine twice a day (group B). Complete ophthalmic examination including Goldmann applanation tonometry was performed before treatment administration and 1, 4, 8, and 12 weeks afterwards. The intraocular pressure (IOP) was measured twice a day (morning at 9 AM and afternoon at 4 PM). At the end of the follow-up period (12 weeks), mean morning IOP reduction was 7.0 ± 2.8 mm Hg in group A and 8.4 ± 1.9 mm Hg in group B. A significant difference was found (p = 0.0343). In contrast, mean afternoon IOP reduction was 8.6 ± 2.7 mm Hg in group A and 7.9 ± 1.6 mm Hg in group B and no significant difference was found (p = 0.3413). No significant adverse effects were observed in either group. Brinzolamide/brimonidine seems to be an effective and safe alternative β-blocker free fixed combination, especially for patients with comorbidities, having its own antihypertensive profile.

  13. Complex Contact Angles Calculated from Capillary Rise Measurements on Rock Fracture Faces

    Science.gov (United States)

    Perfect, E.; Gates, C. H.; Brabazon, J. W.; Santodonato, L. J.; Dhiman, I.; Bilheux, H.; Bilheux, J. C.; Lokitz, B. S.

    2017-12-01

    Contact angles for fluids in unconventional reservoir rocks are needed for modeling hydraulic fracturing leakoff and subsequent oil and gas extraction. Contact angle measurements for wetting fluids on rocks are normally performed using polished flat surfaces. However, such prepared surfaces are not representative of natural rock fracture faces, which have been shown to be rough over multiple scales. We applied a variant of the Wilhelmy plate method for determining contact angle from the height of capillary rise on a vertical surface to the wetting of rock fracture faces by water in the presence of air. Cylindrical core samples (5.05 cm long x 2.54 cm diameter) of Mancos shale and 6 other rock types were investigated. Mode I fractures were created within the cores using the Brazilian method. Each fractured core was then separated into halves exposing the fracture faces. One fracture face from each rock type was oriented parallel to a collimated neutron beam in the CG-1D imaging instrument at ORNL's High Flux Isotope Reactor. Neutron radiography was performed using the multi-channel plate detector with a spatial resolution of 50 μm. Images were acquired every 60 s after a water reservoir contacted the base of the fracture face. The images were normalized to the initial dry condition so that the upward movement of water on the fracture face was clearly visible. The height of wetting at equilibrium was measured on the normalized images using ImageJ. Contact angles were also measured on polished flat surfaces using the conventional sessile drop method. Equilibrium capillary rise on the exposed fracture faces was up to 8.5 times greater than that predicted for polished flat surfaces from the sessile drop measurements. These results indicate that rock fracture faces are hyperhydrophilic (i.e., the height of capillary rise is greater than that predicted for a contact angle of zero degrees). The use of complex numbers permitted calculation of imaginary contact angles for

  14. Role of an anatomically contoured plate and metal block for balanced stability between the implant and lateral hinge in open-wedge high-tibial osteotomy.

    Science.gov (United States)

    Jang, Young Woong; Lim, DoHyung; Seo, Hansol; Lee, Myung Chul; Lee, O-Sung; Lee, Yong Seuk

    2018-07-01

    Open-wedge high tibial osteotomy (OWHTO) is a well-established surgical option for medial compartment osteoarthritis of the varus knee. The initial strength of the fixation plate is critical for successful correction maintenance and healing of the osteotomy site. This study was conducted to verify if a newly designed anatomical plate (LCfit) improves the stability of both the medial implant and lateral hinge area, as well as to evaluate how the metal block contributes to both medial and lateral stability. A finite element (FE) tibial model was combined with TomoFix plate, a LCfit plate with and without a metal block. Data analysis was conducted to evaluate the balanced stability, which refers to the enforced lateral stability resulting from redistribution of overall stress. We assessed the balanced stability of the medial implant and lateral hinge area in three cases using the same Sawbones and loads using the tibia FE model. The LCfit plate reduced stress by 23.1% at the lateral hinge compared to the TomoFix plate (TomoFix vs. LCfit: 34.2 ± 23.3 MPa vs. 26.3 ± 17.5 MPa). The LCfit plate with a metal block reduced stress by 40.1% at the medial plate (210.1 ± 64.2 MPa vs. 125.8 ± 65.7 MPa) and by 31.2% (26.3 ± 17.5 MPa vs. 18.1 ± 12.1 MPa) at the lateral hinge area compared to the reduction using the LCfit plate without a metal block. The newly designed fixation system for OWHTO balanced the overall stress distribution and reduced stress at the lateral hinge area compared to that using a conventional fixation system. The addition of the metal block showed additional benefits for balanced stability between the medial implant and lateral hinge area. However, this conclusion could only be drawn using the FE model in this study. Therefore, further clinical studies are necessary to reveal the clinical effect of reduced lateral stress on the occurrence of the lateral hinge fracture and the biologic effect of the metal block on the

  15. [Case-control study on minimally invasive percutaneous locking compression plate internal fixation for the treatment of type II and III pilon fractures].

    Science.gov (United States)

    Zhang, Zhi-Da; Ye, Xiu-Yi; Shang, Li-Yong; Xu, Rong-Ming; Zhu, Yan-Zhao

    2011-12-01

    To explore the clinical efficacy of delayed open reduction and internal fixation with minimally invasive percutaneous locking compression plate for the treatment of type II and III Pilon fractures. From January 2007 to September 2009, 32 patients with type II and III Pilon fractures were treated with open reduction and anatomic plate fixation (AP group) and minimally invasive percutaneous locking compression plate osteosynthesis (LCP group). There were 11 males and 6 females in AP group, with an average age of (37.4 +/- 13.3) years (ranged, 19 to 55 years). And there were 10 males and 5 females in LCP group, with an average age of (34.6 +/- 11.3) years(ranged, 21 to 56 years). The operating time, fracture healing time, aligned angulation and ankle function were compared between the two groups. All the patients were followed up, and the during ranged from 12 to 25 months, with a mean of (15.0 +/- 1.7) months. The average operation time was (76.5 +/- 8.3) min for AP group and (58.3 +/- 3.4) min for LCP group; the average time of fracture healing was (20.5 +/- 0.4) weeks for AP group and (15.7 +/- 0.2) weeks for LCP group; the total angulation between anterior posterior film and lateral film was averaged (6.6 +/- 0.5) degrees for AP group and (3.6 +/- 0.2) degrees for LCP group. As to above index, the results of LCP group were better than those of AP group (P ankle joint, the results of LCP group were better than those of AP group in ankle joint pain, wakling and ankle joint function (P fracture with less invasion, faster bone union, more stabilized fixation, quicker recovery of ankle function and fewer complications, which is more advantaged for type II and III Pilon fractures.

  16. Experimental study of fluid flow in the entrance of a sinusoidal channel

    International Nuclear Information System (INIS)

    Oviedo-Tolentino, F.; Romero-Mendez, R.; Hernandez-Guerrero, A.; Giron-Palomares, B.

    2008-01-01

    An experimental flow visualization study of the entrance section of channels formed with sinusoidal plates was made. The experiments were conducted in a water tunnel and a laser illuminated particle tracking was used as the technique of flow visualization. The geometric parameters of the plates were maintained constant while the distance between plates, phase angle, and the Reynolds number were varied during the experiments. The flow regimes that were found in the experiments are steady, unsteady and significantly-mixed flows. Instabilities of the flow first appear near the exit of the channel, and move closer to the inlet waves as the Reynolds number grows, but in the first wave from inlet the flow is always steady. The results show that, for all other parameters fixed, the Reynolds number at which unsteady flow first appears grows with the distance between plates. The phase angle that best promotes unsteady flow depends on the average distance between plates: for certain average distance between plates, there is a phase angle that best disturbs the flow. For the set of parameters used in this experiment, a channel with eight waves is sufficiently long and the flow features presented in the first eight waves of a longer channel will be similar to what was observed here

  17. Numerical Study on Ultimate Behaviour of Bolted End-Plate Steel Connections

    Directory of Open Access Journals (Sweden)

    R.E.S. Ismail

    Full Text Available Abstract Bolted end-plate steel connections have become more popular due to ease of fabrication. This paper presents a three dimension Finite Element Model (FEM, using the multi-purpose software ABAQUS, to study the effect of different geometrical parameters on the ultimate behavior of the connection. The proposed model takes into account material and geometrical non-linearities, initial imperfection, contact between adjacent surfaces and the pretension force in the bolts. The Finite Element results are calibrated with published experimental results ''briefly reviewed in this paper'' and verified that the numerical model can simulate and analyze the overall and detailed behavior of different types of bolted end-plate steel connections. Using verified FEM, parametric study is then carried out to study the ultimate behavior with variations in: bolt diameter, end-plate thickness, length of column stiffener, angle of rib stiffener. The results are examined with respect to the failure modes, the evolution of the resistance, the initial stiffness, and the rotation capacity. Finally, the ultimate behavior of the bolted end-plate steel connection is discussed in detail, and recommendations for the design purpose are made.

  18. Determination of Fracture Parameters for Multiple Cracks of Laminated Composite Finite Plate

    Science.gov (United States)

    Srivastava, Amit Kumar; Arora, P. K.; Srivastava, Sharad Chandra; Kumar, Harish; Lohumi, M. K.

    2018-04-01

    A predictive method for estimation of stress state at zone of crack tip and assessment of remaining component lifetime depend on the stress intensity factor (SIF). This paper discusses the numerical approach for prediction of first ply failure load (FL), progressive failure load, SIF and critical SIF for multiple cracks configurations of laminated composite finite plate using finite element method (FEM). The Hashin and Chang failure criterion are incorporated in ABAQUS using subroutine approach user defined field variables (USDFLD) for prediction of progressive fracture response of laminated composite finite plate, which is not directly available in the software. A tensile experiment on laminated composite finite plate with stress concentration is performed to validate the numerically predicted subroutine results, shows excellent agreement. The typical results are presented to examine effect of changing the crack tip distance (S), crack offset distance (H), and stacking fiber angle (θ) on FL, and SIF .

  19. UK DRAFFT - A randomised controlled trial of percutaneous fixation with kirschner wires versus volar locking-plate fixation in the treatment of adult patients with a dorsally displaced fracture of the distal radius

    Directory of Open Access Journals (Sweden)

    Brown Jaclyn

    2011-09-01

    Full Text Available Abstract Background Fractures of the distal radius are extremely common injuries in adults. However, the optimal management remains controversial. In general, fractures of the distal radius are treated non-operatively if the bone fragments can be held in anatomical alignment by a plaster cast or orthotic. However, if this is not possible, then operative fixation is required. There are several operative options but the two most common in the UK, are Kirschner-wire fixation (K-wires and volar plate fixation using fixed-angle screws (locking-plates. The primary aim of this trial is to determine if there is a difference in the Patient-Reported Wrist Evaluation one year following K-wire fixation versus locking-plate fixation for adult patients with a dorsally-displaced fracture of the distal radius. Methods/design All adult patients with an acute, dorsally-displaced fracture of the distal radius, requiring operative fixation are potentially eligible to take part in this study. A total of 390 consenting patients will be randomly allocated to either K-wire fixation or locking-plate fixation. The surgery will be performed in trauma units across the UK using the preferred technique of the treating surgeon. Data regarding wrist function, quality of life, complications and costs will be collected at six weeks and three, six and twelve months following the injury. The primary outcome measure will be wrist function with a parallel economic analysis. Discussion This pragmatic, multi-centre trial is due to deliver results in December 2013. Trial registration Current Controlled Trials ISRCTN31379280 UKCRN portfolio ID 8956

  20. Astrometric properties of the Tautenburg Plate Scanner

    Science.gov (United States)

    Brunzendorf, Jens; Meusinger, Helmut

    The Tautenburg Plate Scanner (TPS) is an advanced plate-measuring machine run by the Thüringer Landessternwarte Tautenburg (Karl Schwarzschild Observatory), where the machine is housed. It is capable of digitising photographic plates up to 30 cm × 30 cm in size. In our poster, we reported on tests and preliminary results of its astrometric properties. The essential components of the TPS consist of an x-y table movable between an illumination system and a direct imaging system. A telecentric lens images the light transmitted through the photographic emulsion onto a CCD line of 6000 pixels of 10 µm square size each. All components are mounted on a massive air-bearing table. Scanning is performed in lanes of up to 55 mm width by moving the x-y table in a continuous drift-scan mode perpendicular to the CCD line. The analogue output from the CCD is digitised to 12 bit with a total signal/noise ratio of 1000 : 1, corresponding to a photographic density range of three. The pixel map is produced as a series of optionally overlapping lane scans. The pixel data are stored onto CD-ROM or DAT. A Tautenburg Schmidt plate 24 cm × 24 cm in size is digitised within 2.5 hours resulting in 1.3 GB of data. Subsequent high-level data processing is performed off-line on other computers. During the scanning process, the geometry of the optical components is kept fixed. The optimal focussing of the optics is performed prior to the scan. Due to the telecentric lens refocussing is not required. Therefore, the main source of astrometric errors (beside the emulsion itself) are mechanical imperfections in the drive system, which have to be divided into random and systematic ones. The r.m.s. repeatability over the whole plate as measured by repeated scans of the same plate is about 0.5 µm for each axis. The mean plate-to-plate accuracy of the object positions on two plates with the same epoch and the same plate centre has been determined to be about 1 µm. This accuracy is comparable to

  1. Kinematics of reflections in subsurface offset and angle-domain image gathers

    Science.gov (United States)

    Dafni, Raanan; Symes, William W.

    2018-05-01

    Seismic migration in the angle-domain generates multiple images of the earth's interior in which reflection takes place at different scattering-angles. Mechanically, the angle-dependent reflection is restricted to happen instantaneously and at a fixed point in space: Incident wave hits a discontinuity in the subsurface media and instantly generates a scattered wave at the same common point of interaction. Alternatively, the angle-domain image may be associated with space-shift (regarded as subsurface offset) extended migration that artificially splits the reflection geometry. Meaning that, incident and scattered waves interact at some offset distance. The geometric differences between the two approaches amount to a contradictory angle-domain behaviour, and unlike kinematic description. We present a phase space depiction of migration methods extended by the peculiar subsurface offset split and stress its profound dissimilarity. In spite of being in radical contradiction with the general physics, the subsurface offset reveals a link to some valuable angle-domain quantities, via post-migration transformations. The angle quantities are indicated by the direction normal to the subsurface offset extended image. They specifically define the local dip and scattering angles if the velocity at the split reflection coordinates is the same for incident and scattered wave pairs. Otherwise, the reflector normal is not a bisector of the opening angle, but of the corresponding slowness vectors. This evidence, together with the distinguished geometry configuration, fundamentally differentiates the angle-domain decomposition based on the subsurface offset split from the conventional decomposition at a common reflection point. An asymptotic simulation of angle-domain moveout curves in layered media exposes the notion of split versus common reflection point geometry. Traveltime inversion methods that involve the subsurface offset extended migration must accommodate the split geometry

  2. Determination of the Optimal Tilt Angle for Solar Photovoltaic Panel in Ilorin, Nigeria

    Directory of Open Access Journals (Sweden)

    K.R. Ajao

    2013-06-01

    Full Text Available The optimal tilt angle of solar photovoltaic panel in Ilorin, Nigeria was determined. The solar panel was first mounted at 0o to the horizontal and after ten minutes, the voltage and current generated with the corresponding atmospheric temperature were recorded. The same procedure was repeated for 2o to 30o at a succession of 2o at ten minutes time interval over the entire measurement period. The result obtained shows that the average optimal tilt angle at which a solar panel will be mounted for maximum power performance at fixed position in Ilorin is 22o. This optimum angle of tilt of the solar panel and the orientation are dependent on the month of the year and the location of the site of study.

  3. PHB, crystalline and amorphous magnesium alloys: Promising candidates for bioresorbable osteosynthesis implants?

    Energy Technology Data Exchange (ETDEWEB)

    Celarek, Anna [Institute for Building Construction and Technology E-206-4, Vienna University of Technology, Karlsplatz 13, 1040 Vienna (Austria); Kraus, Tanja [Department of Paediatric Orthopaedics, Medical University of Graz, Auenbruggerplatz 34, 8036 Graz (Austria); Tschegg, Elmar K., E-mail: elmar.tschegg@tuwien.ac.at [Institute for Building Construction and Technology E-206-4, Vienna University of Technology, Karlsplatz 13, 1040 Vienna (Austria); Fischerauer, Stefan F. [Department of Paediatric and Adolescent Surgery, Medical University of Graz, Auenbruggerplatz 34, 8036 Graz (Austria); Stanzl-Tschegg, Stefanie [Department of Material Sciences and Process Engineering, Institute of Physics and Materials Science, University of Natural Resources and Life Sciences, Peter Jordan Str. 82, 1190 Vienna (Austria); Uggowitzer, Peter J. [Department of Materials, Laboratory for Metal Physics and Technology, ETH Zurich, 8093 Zurich (Switzerland); Weinberg, Annelie M. [Department of Paediatric and Adolescent Surgery, Medical University of Graz, Auenbruggerplatz 34, 8036 Graz (Austria)

    2012-08-01

    In this study various biodegradable materials were tested for their suitability for use in osteosynthesis implants, in particular as elastically stable intramedullary nails for fracture treatment in paediatric orthopaedics. The materials investigated comprise polyhydroxybutyrate (PHB), which belongs to the polyester family and is produced by microorganisms, with additions of ZrO{sub 2} and a bone graft substitute; two crystalline magnesium alloys with significantly different degradation rates ZX50 (MgZnCa, fast) and WZ21 (MgYZnCa, slow); and MgZnCa bulk metallic glasses (BMG). Push-out tests were conducted after various implantation times in rat femur meta-diaphysis to evaluate the shear forces between the implant material and the bone. The most promising materials are WZ21 and BMG, which exhibit high shear forces and push-out energies. The degradation rate of ZX50 is too fast and thus the alloy does not maintain its mechanical stability long enough during the fracture-healing period. PHB exhibits insufficient mechanical properties: it degrades very slowly and the respective low shear forces and push-out energy levels are unsatisfactory. - Highlights: Black-Right-Pointing-Pointer In-vivo (rat model) investigation of biodegradable materials suitable for ESIN. Black-Right-Pointing-Pointer Materials: polymer PHB, crystalline Mg ZX50 and Mg WZ21, MgZnCa bulk metallic glasses. Black-Right-Pointing-Pointer Evaluated interface shear strength, push-out energies, stiffness, histology. Black-Right-Pointing-Pointer Mg WZ21 suitable, other materials only after alterations.

  4. [Titanium or steel as osteosynthesis material : Systematic literature search for clinical evidence].

    Science.gov (United States)

    Joeris, Alexander; Goldhahn, Sabine; Rometsch, Elke; Höntzsch, Dankward

    2017-02-01

    The selection of the appropriate implant material, stainless steel or titanium, is still the decision of the surgeon and/or the affiliated institution. Additionally, remarkable international differences can be found between the different markets, which cannot really be explained. A systematic literature search was performed to verify whether there is clinical evidence for the preference of one material over the other. The systematic literature search was performed utilizing the internet databases PubMed, Cochrane and Web of Science. Comparative studies were included that reported on adult patients with osteosynthesis of extremities after trauma using either stainless steel or titanium implants. Information was extracted about infection rates, incidence of clinically relevant allergies, problems with implant removal and other complications. A total of 18 publications were identified to be eligible and 2 referenced articles were added. In summary, there is insufficient clinical evidence that the use of titanium or steel implants has a positive or negative effect on fracture healing, shows different rates of allergies, different rates of infections or mechanical failure. No supporting evidence could be identified for the difficulties with removal of titanium implants reported by surgeons. This systematic literature search did not provide any clinical evidence for material-related differences between titanium or stainless steel implants for fracture fixation. Based on the current clinical evidence both titanium and steel implants can be considered to be of equal value. The reported difficulties with implant removal are not reflected in the published literature.

  5. PHB, crystalline and amorphous magnesium alloys: Promising candidates for bioresorbable osteosynthesis implants?

    International Nuclear Information System (INIS)

    Celarek, Anna; Kraus, Tanja; Tschegg, Elmar K.; Fischerauer, Stefan F.; Stanzl-Tschegg, Stefanie; Uggowitzer, Peter J.; Weinberg, Annelie M.

    2012-01-01

    In this study various biodegradable materials were tested for their suitability for use in osteosynthesis implants, in particular as elastically stable intramedullary nails for fracture treatment in paediatric orthopaedics. The materials investigated comprise polyhydroxybutyrate (PHB), which belongs to the polyester family and is produced by microorganisms, with additions of ZrO 2 and a bone graft substitute; two crystalline magnesium alloys with significantly different degradation rates ZX50 (MgZnCa, fast) and WZ21 (MgYZnCa, slow); and MgZnCa bulk metallic glasses (BMG). Push-out tests were conducted after various implantation times in rat femur meta-diaphysis to evaluate the shear forces between the implant material and the bone. The most promising materials are WZ21 and BMG, which exhibit high shear forces and push-out energies. The degradation rate of ZX50 is too fast and thus the alloy does not maintain its mechanical stability long enough during the fracture-healing period. PHB exhibits insufficient mechanical properties: it degrades very slowly and the respective low shear forces and push-out energy levels are unsatisfactory. - Highlights: ► In-vivo (rat model) investigation of biodegradable materials suitable for ESIN. ► Materials: polymer PHB, crystalline Mg ZX50 and Mg WZ21, MgZnCa bulk metallic glasses. ► Evaluated interface shear strength, push-out energies, stiffness, histology. ► Mg WZ21 suitable, other materials only after alterations.

  6. Numerical Study of the Effect of Presence of Geometric Singularities on the Mechanical Behavior of Laminated Plates

    Science.gov (United States)

    Khechai, Abdelhak; Tati, Abdelouahab; Guettala, Abdelhamid

    2017-05-01

    In this paper, an effort is made to understand the effects of geometric singularities on the load bearing capacity and stress distribution in thin laminated plates. Composite plates with variously shaped cutouts are frequently used in both modern and classical aerospace, mechanical and civil engineering structures. Finite element investigation is undertaken to show the effect of geometric singularities on stress distribution. In this study, the stress concentration factors (SCFs) in cross-and-angle-ply laminated as well as in isotropic plates subjected to uniaxial loading are studied using a quadrilateral finite element of four nodes with thirty-two degrees-of-freedom per element. The varying parameters such as the cutout shape and hole sizes (a/b) are considered. The numerical results obtained by the present element are compared favorably with those obtained using the finite element software Freefem++ and the analytic findings published in literature, which demonstrates the accuracy of the present element. Freefem++ is open source software based on the finite element method, which could be helpful to study and improving the analyses of the stress distribution in composite plates with cutouts. The Freefem++ and the quadrilateral finite element formulations will be given in the beginning of this paper. Finally, to show the effect of the fiber orientation angle and anisotropic modulus ratio on the (SCF), number of figures are given for various ratio (a/b).

  7. The neutron small-angle camera D11 at the high-flux reactor, Grenoble

    International Nuclear Information System (INIS)

    Ibel, K.

    1976-01-01

    The neutron small-angle scattering system at the high-flux reactor in Grenoble consists of three major parts: the supply of cold neutrons via bent neutron guides; the small-angle camera D11; and the data handling facilities. The camera D11 has an overall length of 80 m. The effective length of the camera is variable. The full length of the collimator before the fixed sample position can be reduced by movable neutron guides; the second flight path of 40 m full length contains detector sites in various positions. Thus a large range of momentum transfers can be used with the same relative resolution. Scattering angles between 5 x 10 -4 and 0.5 rad and neutron wavelengths from 0.2 to 2.0 nm are available. A large-area position-sensitive detector is used which allows simultaneous recording of intensities scattered at different angles; it is a multiwire proportional chamber. 3808 elements of 1 cm 2 are arranged in a two-dimensional matrix. (Auth.)

  8. Open-wedge osteotomy using an internal plate fixator in patients with medial-compartment gonarthritis and varus malalignment

    DEFF Research Database (Denmark)

    Niemeyer, Philipp; Schmal, Hagen; Hauschild, Oliver

    2010-01-01

    PURPOSE: Our purpose was to evaluate the 3-year clinical results of patients with medial-compartment osteoarthritis of the knee and varus malalignment who underwent open-wedge high tibial osteotomy (HTO) with an internal plate fixator (TomoFix; Synthes, Solothurn, Switzerland). Clinical results a...

  9. RESEARCH OF THE ENTRANCE ANGLE EFFECT ON THE REFLECTANCE SPECTRA OF THE STAINLESS STEEL SURFACE OXIDIZED BY PULSED LASER RADIATION

    Directory of Open Access Journals (Sweden)

    V. P. Veiko

    2016-05-01

    Full Text Available Subject of Research.Oxide films on the metal surfaces can be obtained both by surface-uniform infrared heating and local laser treatment e.g. by sequence of nanosecond laser pulses. Due to interference in created films the coloration of treated area is observed. The present work shows the results of spectrophotometric measurements for various light entrance angles in the range of 10-60°. Method. AISI 304 stainless steel plates were oxidized by two methods: in muffle furnace FM - 10 (Т= 500-600° С, t = 5-7 min. and at line-by-line scanning by sequence of nanosecond laser pulses (λ = 1.06 μm, τ =100 ns, r = 25 μm,q=2.91∙107 W/cm2, Nx = 30, Ny = 1. Surface research in optical resolution was realized by Carl Zeiss Axio Imager A1M. Reflectance spectra were obtained with spectrophotometer Lambda Perkin 1050 with integrating sphere at different fixed light incidence angles. Topographic features were detected by scanning probe microscopy investigation with NanoEducator equipment. Main Results. The quantitative surface geometry characteristics of AISI 304 stainless steel patterns treated by different methods are obtained. It was found that the increase of light entrance angle has no influence on the form of reflection coefficient dependence from a wavelength, but a blue-shift occurs especially for the case of laser treatment. This difference can be caused by surface topology formed by laser heating and variety of oxide film thickness. This effect results in more significant change in observed sample color for laser treatment then for infrared heating. Practical Relevance. The results obtained in the present work can be used to implement a new element of product protection against forgery with the product marking.

  10. Improved Beam Angle Arrangement in Intensity Modulated Proton Therapy Treatment Planning for Localized Prostate Cancer

    International Nuclear Information System (INIS)

    Cao, Wenhua; Lim, Gino J.; Li, Yupeng; Zhu, X. Ronald; Zhang, Xiaodong

    2015-01-01

    Purpose: This study investigates potential gains of an improved beam angle arrangement compared to a conventional fixed gantry setup in intensity modulated proton therapy (IMPT) treatment for localized prostate cancer patients based on a proof of principle study. Materials and Methods: Three patients with localized prostate cancer retrospectively selected from our institution were studied. For each patient, IMPT plans were designed using two, three and four beam angles, respectively, obtained from a beam angle optimization algorithm. Those plans were then compared with ones using two lateral parallel-opposed beams according to the conventional planning protocol for localized prostate cancer adopted at our institution. Results: IMPT plans with two optimized angles achieved significant improvements in rectum sparing and moderate improvements in bladder sparing against those with two lateral angles. Plans with three optimized angles further improved rectum sparing significantly over those two-angle plans, whereas four-angle plans found no advantage over three-angle plans. A possible three-beam class solution for localized prostate patients was suggested and demonstrated with preserved dosimetric benefits because individually optimized three-angle solutions were found sharing a very similar pattern. Conclusions: This study has demonstrated the potential of using an improved beam angle arrangement to better exploit the theoretical dosimetric benefits of proton therapy and provided insights of selecting quality beam angles for localized prostate cancer treatment

  11. An experimental study of the supersonic, dual, coaxial jets impinging on an inclined flat plate

    International Nuclear Information System (INIS)

    Kim, Jung Bae; Lee, Jun Hee; Woo, Sun Hoon; Kim, Heuy Dong

    2002-01-01

    The impinging supersonic jets have been applied for rocket launching system, thrust control, gas turbine blade cooling, etc. Recently the supersonic, dual, coaxial jets are being extensively used in many diverse fields of industrial processes since they lead to more improved performance, compared with the conventional supersonic jets impinging on an object. In the present study, experimentation is carried out to investigate the supersonic, dual, coaxial jets impinging on an inclined flat plate. A convergent-divergent nozzle with a design Mach number of 2.0 and annular sonic nozzle are used to make the dual, coaxial jet flows. The angle of the impinging flat plate is varied from 30 .deg. to 60 .deg. and the distance between the dual coaxial nozzle and flat plate is also varied. Detailed pressures on the impinging plate are measured to analyze the flow fields, which are also visualized using Schlieren optical method

  12. Broadband one-dimensional photonic crystal wave plate containing single-negative materials.

    Science.gov (United States)

    Chen, Yihang

    2010-09-13

    The properties of the phase shift of wave reflected from one-dimensional photonic crystals consisting of periodic layers of single-negative (permittivity- or permeability-negative) materials are demonstrated. As the incident angle increases, the reflection phase shift of TE wave decreases, while that of TM wave increases. The phase shifts of both polarized waves vary smoothly as the frequency changes across the photonic crystal stop band. Consequently, the difference between the phase shift of TE and that of TM wave could remain constant in a rather wide frequency range inside the stop band. These properties are useful to design wave plate or retarder which can be used in wide spectral band. In addition, a broadband photonic crystal quarter-wave plate is proposed.

  13. PERFORMANCE ANALYSIS OF A HELICAL SAVONIUS ROTOR WITHOUT SHAFT AT 45° TWIST ANGLE USING CFD

    Directory of Open Access Journals (Sweden)

    Bachu Deb

    2013-06-01

    Full Text Available Helical Savonius rotor exhibits better performance characteristics at all the rotor angles compared to conventional Savonius rotor. However studies related to the performance measurement and flow physics of such rotor are very scarce. Keeping this in view, in this paper, a three dimensional Computational Fluid Dynamics analysis using commercial Fluent 6.2 software was done to predict the performance of a two-bucket helical Savonius rotor without shaft and with end plates in a complete cycle of rotation. A two-bucket helical Savonius rotor having height of 60 cm and diameter of 17 cm with 45° bucket twist angle was designed using Gambit. The buckets were connected at the top and bottom circular end plates, which are 1.1 times the rotor diameter. The k-ε turbulence model with second order upwind discretization scheme was adopted with standard wall condition. Power coefficients (Cp and torque coefficients (Ct at different tip speed ratios were evaluated at different rotor angles. From the investigation, it was observed that power coefficient increased with increase of tip speed ratio up to an optimum limit, but then decreased even further tip speed ratio was increased. Further investigation was done on the variations of Cp & Ct in a complete cycle of rotation from 0° to 360° in a step of 45° rotor corresponding to the optimum tip speed ratio. The value of Cp at all the rotor angles is positive. Moreover, velocity magnitude contours were analyzed for each rotor angle and it could be concluded that high aerodynamic torque and power can be expected when the rotor is positioned at 45º & 90º with respect to incoming flow.

  14. Variation of reflected radiation from all reflectors of a flat plate solar collector during a year

    International Nuclear Information System (INIS)

    Pavlović, Zoran T.; Kostić, Ljiljana T.

    2015-01-01

    In this paper the impact of flat plate reflectors (bottom, top, left and right reflectors) made of Al, on total solar radiation on a solar collector during a day time over a whole year is analyzed. An analytical model for determining optimum tilt angles of a collector and reflectors for any point on the Earth is proposed. Variations of reflectors' optimal inclination angles with changes of the collector's optimal tilt angle during the year are also calculated. Optimal inclination angles of the reflectors for the South directed solar collector are calculated and compared to experimental data. It is shown that optimal inclination of the bottom reflector is the lowest in December and the highest in June, while for the top reflector the lowest value is in June and the highest value is in December. On the other hand, optimal inclination of the left and right side reflectors for optimum tilt angle of the collector does not change during the year and it is 66°. It is found that intensity of the solar radiation on the collector increases for about 80% in the summer period (June–September) by using optimally inclined reflectors, in comparison to the collector without reflectors. - Highlights: • The impacts of flat plate reflectors on solar radiation on the collector are given. • The results of the optimal inclinations of reflectors during the year are shown. • The solar radiation on the collector with reflectors is 80% higher in the summer. • This model may be applied on thermal, PV, PV/T and energy harvesting systems

  15. Study of electrodeposition technique to prepare alpha-counting plates of uranium 233

    International Nuclear Information System (INIS)

    Mertzig, W.

    1979-01-01

    The electrodeposition technique to prepare alpha-counting plates of 233 U for its determination is presented. To determine the optimum conditions for plating 233 U the effects of such parameters as current density, pH of eletrotype, salt concentration, time of electrolysis and distance electrodes were studied. A carrier method was developed to attain a quantitative electrodeposition of 233 U from aqueous solutions into alpha counting paltes. A single and incremental addition of natural uranium and thorium as carrier were studied. All samples were prepared using a electrodeposition cell manufactured at the IPEN, especially for use in electroplating tracer actinides. This cell is made of a metal-lucite to contain the electrolyte, which bottom is a polished brass disk coated with a Ni film serving as the cathode. A Pt wire anode is fixed on the top of the cell. The electroplated samples were alpha-counted using a surface barrier detector. A recovery of more than 99% was obtained in specific conditions. The plating procedure produced deposits which were firmly distributed over the plate area. The method was applied to determine tracer amounts of 233 U from oxalate and nitrate solutions coming from chemical processing irradiated thorium. (Author) [pt

  16. [NITINOL shape memory staple for osteosynthesis of the scaphoid].

    Science.gov (United States)

    Winkel, Reiner; Schlageter, Michael

    2009-11-01

    Reconstruction of the scaphoid with use of NITINOL shape "memory" staples. Unstable fractures and nonunion of the middle third of the scaphoid, which need open reduction and internal fixation from palmar. The staples can only be used, if the arms of the staples can be inserted parallel to and at a distance of 3 mm to the fracture line. Allergy to nickel. Cases in which the arms of the staple cannot be inserted parallel to and at best 3 mm apart from the fracture line. In fractures, open reduction of the scaphoid through a palmar approach. If necessary, interposition of a bone graft and Kirschner wire transfixation. Drilling of the drill holes parallel and at a distance of 3 mm to the fracture line. Insertion of the NITINOL staple. In nonunion, excision of the fibrous nonunion, refreshening of the fracture surfaces, interposition of a bone graft and, if needed, fixation with a Kirschner wire. Drilling of the drill holes for the NITINOL staple and insertion of the staple. Within a few minutes the warming-up staple contracts and thereby compresses the scaphoid. Immobilization in a short cast with thumb support for 6 weeks. Control for bone healing by radiographs or computed tomography. Staples, which do not cause hardware problems, are not removed. Kirschner wires are removed after bone healing. From October 1995 to December 2006, the authors used NITINOL staples for 65 osteosyntheses of the scaphoid. Indications were 15 unstable fractures, 47 nonunions, and three partial necroses. 61 out of 65 scaphoids healed without further surgery, three of the 61 patients showed a delayed healing. Two of the four nonunions were related to the use of the NITINOL staples. Seven staples were removed, one for loosening. NITINOL shape memory staples have proven to be very helpful for osteosynthesis in fractures and nonunion of the scaphoid, if the prerequisites are given for their use.

  17. Experimental and numerical investigation on laser-assisted bending of pre-loaded metal plate

    Science.gov (United States)

    Nowak, Zdzisław; Nowak, Marcin; Widłaszewski, Jacek; Kurp, Piotr

    2018-01-01

    The laser forming technique has an important disadvantage, which is the limitation of plastic deformation generated by a single laser beam pass. To increase the plastic deformation it is possible to apply external forces in the laser forming process. In this paper, we investigate the influence of external pre-loads on the laser bending of steel plate. The pre-loads investigated generate bending towards the laser beam. The thermal, elastic-plastic analysis is performed using the commercial nonlinear finite element analysis package ABAQUS. The focus of the paper is to identify how this pattern of the pre-load influence the final bend angle of the plate.

  18. Variable flip angle excitation for reduced acquisition time magnetic resonance imaging

    International Nuclear Information System (INIS)

    Mills, T.C.; Ortendahl, D.A.; Hylton, N.M.; Carlson, J.W.; Crooks, L.E.; Kaufman, L.

    1987-01-01

    This paper describes an MRI technique which can be used to acquire images at short TR values while maintaining the sensitivity to disease found in longer TR images. For spin echo imaging there are three acquisition parameters that can be set in the imaging protocol; TR, the repetition interval; TE, the time of echo and Θ, the excitation flip angle. Standard imaging techniques set Θ to 90 degrees regardless of the TR value. With Θ fixed, imaging systems have been optimized by varying the value for TE and TR with the results in general indicating the need for long TR values. However, if the flip angle is included as a variable acquisition parameter the optimal operating point can be changed. The solution to the Bloch equation shows a functional relationship between the flip angle and the ratio TR/T1. This functionality was first observed by Ernst and Anderson as a method to increase the signal generated in fourier transform magnetic resonance spectroscopy. When TR/T1<1 the optimum flip angle for producing maximum magnetization in the transverse plane is less then 90 degrees. Therefore, by reducing both TR and flip angle it is possible to maintain signal intensity while reducing the time of data acquisition

  19. Effects of drop size and measuring condition on static contact angle measurement on a superhydrophobic surface with goniometric technique

    International Nuclear Information System (INIS)

    Seo, Kwangseok; Kim, Minyoung; Kim, Do Hyun; Ahn, Jeong Keun

    2015-01-01

    It is not a simple task to measure a contact angle of a water drop on a superhydrophobic surface with sessile drop method, because a roll-off angle is very low. Usually contact angle of a water drop on a superhydrophobic surface is measured by fixing a drop with intentional defects on the surface or a needle. We examined the effects of drop size and measuring condition such as the use of a needle or defects on the static contact angle measurement on superhydrophobic surface. Results showed that the contact angles on a superhydrophobic surface remain almost constant within intrinsic measurement errors unless there is a wetting transition during the measurement. We expect that this study will provide a deeper understanding on the nature of the contact angle and convenient measurement of the contact angle on the superhydrophobic surface.

  20. Polar plate theory for orthogonal anisotropy

    Science.gov (United States)

    Bailey, Michelle D.

    1998-11-01

    The following paper discusses the derivation and evaluation of the plate equations for a circular composite disk with orthogonal anisotropy. The work will be on a macromechanical level and include buckling, static and dynamic load applications. Necessary to a complete examination of the circular disk is the conversion of the stiffness matrix to cylindrical coordinates. In the transformed state, these coefficients are no longer constant, adding to the complexity of the proposed differential equations. Laminated fiber-reinforced (or filamentary) composites are used today for their high strength-to weight and stiffness-to-weight ratios. However, because of the typical anisotropic behavior of composites, determining the material properties on a microscopic level and the mechanics on a macroscopic level is much more difficult. This difficulty manifests itself particularly well in the evaluation of material properties and governing differential equations of a circular disk with the fibers of the lamina oriented orthogonally. One could encounter such a situation in space structures that require a circular geometry. For example, determining fastener pull through in a circular composite plate would best be performed in a polar coordinate system. In order to calculate the strain (which is a function of the angle, θ) from the displacements, the stiffness matrix and boundary conditions would need to be expressed in cylindrical coordinates. Naturally the composite would be constructed with fibers in orthogonal directions, then the necessary geometry would be cut out, thus the required lengthy transformation of coordinate systems. To bypass this derivation, numerical methods have been used and finite element models have been attempted. FEM over predicts plate stiffness by 20% and underpredicts failure by 70%. Obviously there is a need to transform classical plate theory to a cylindrical coordinate system.