WorldWideScience

Sample records for fire safety storage

  1. Fire safety

    Keski-Rahkonen, O.; Bjoerkman, J.; Hostikka, S.; Mangs, J.; Huhtanen, R.; Palmen, H.; Salminen, A.; Turtola, A.

    1998-01-01

    According to experience and probabilistic risk assessments, fires present a significant hazard in a nuclear power plant. Fires may be initial events for accidents or affect safety systems planned to prevent accidents and to mitigate their consequences. The project consists of theoretical work, experiments and simulations aiming to increase the fire safety at nuclear power plants. The project has four target areas: (1) to produce validated models for numerical simulation programmes, (2) to produce new information on the behavior of equipment in case of fire, (3) to study applicability of new active fire protecting systems in nuclear power plants, and (4) to obtain quantitative knowledge of ignitions induced by important electric devices in nuclear power plants. These topics have been solved mainly experimentally, but modelling at different level is used to interpret experimental data, and to allow easy generalisation and engineering use of the obtained data. Numerical fire simulation has concentrated in comparison of CFD modelling of room fires, and fire spreading on cables on experimental data. So far the success has been good to fair. A simple analytical and numerical model has been developed for fire effluents spreading beyond the room of origin in mechanically strongly ventilated compartments. For behaviour of equipment in fire several full scale and scaled down calorimetric experiments were carried out on electronic cabinets, as well as on horizontal and vertical cable trays. These were carried out to supply material for CFD numerical simulation code validation. Several analytical models were developed and validated against obtained experimental results to allow quick calculations for PSA estimates as well as inter- and extrapolations to slightly different objects. Response times of different commercial fire detectors were determined for different types of smoke, especially emanating from smoldering and flaming cables to facilitate selection of proper detector

  2. Fire Safety (For Parents)

    ... Staying Safe Videos for Educators Search English Español Fire Safety KidsHealth / For Parents / Fire Safety What's in ... event of a fire emergency in your home. Fire Prevention Of course, the best way to practice ...

  3. Fires and Food Safety

    ... Forms FSIS United States Department of Agriculture Food Safety and Inspection Service About FSIS District Offices Careers ... JSR 286) Actions ${title} Loading... Fires and Food Safety Fire! Few words can strike such terror. Residential ...

  4. Spacecraft Fire Safety Demonstration

    National Aeronautics and Space Administration — The objective of the Spacecraft Fire Safety Demonstration project is to develop and conduct large-scale fire safety experiments on an International Space Station...

  5. Fire, safety and ventilation

    Hindle, D.

    1999-02-01

    Correct ventilation in tunnel environments is vital for the comfort and safety of the people passing through. This article gives details of products from several manufacturers of safety rescue and fire fighting equipment, fire and fume detection equipment, special fire resistant materials, fire resistant hydraulic oils and fire dampers, and ventilation systems. Company addresses and fax numbers are supplied. 4 refs., 5 tabs., 10 photos.

  6. Fire safety engineering

    Smith, D.N.

    1989-01-01

    The periodic occurrence of large-scale, potentially disastrous industrial accidents involving fire in hazardous environments such as oilwell blowouts, petrochemical explosions and nuclear installations highlights the need for an integrated approach to fire safety engineering. Risk reduction 'by design' and rapid response are of equal importance in the saving of life and property in such situations. This volume of papers covers the subject thoroughly, touching on such topics as hazard analysis, safety design and testing, fire detection and control, and includes studies of fire hazard in the context of environment protection. (author)

  7. Fire Safety Deficiencies

    U.S. Department of Health & Human Services — A list of all fire safety deficiencies currently listed on Nursing Home Compare, including the nursing home that received the deficiency, the associated inspection...

  8. Smoking and Home Fire Safety

    ... Materials Working with the Media Fire Protection Technology Smoking fire safety outreach materials As a member of ... Not reported 7% In transport 1% 195 incidents Smoking fire safety messages to share It is important ...

  9. Fire safety of wood construction

    Robert H. White; Mark A. Dietenberger

    2010-01-01

    Fire safety is an important concern in all types of construction. The high level of national concern for fire safety is reflected in limitations and design requirements in building codes. These code requirements and related fire performance data are discussed in the context of fire safety design and evaluation in the initial section of this chapter. Because basic data...

  10. Fire safety at home

    ... over the smoke alarm as needed. Using a fire extinguisher can put out a small fire to keep it from getting out of control. Tips for use include: Keep fire extinguishers in handy locations, at least one on ...

  11. Fire safety regulations and licensing

    Berg, H.P.

    1998-01-01

    Experience of the past tow decades of nuclear power plant operation and results obtained from modern analytical techniques confirm that fires may be a real threat to nuclear safety and should receive adequate attention from the design phase throughout the life of the plant. Fire events, in particular influence significantly plant safety due to the fact that fires have the potential to simultaneously damage components of redundant safety-related equipment. Hence, the importance of fire protection for the overall safety of a nuclear power plant has to be reflected by the fire safety regulations and to be checked during the licensing process of a plant as well as during the continuous supervision of the operating plant

  12. Fire safety analysis: methodology

    Kazarians, M.

    1998-01-01

    From a review of the fires that have occurred in nuclear power plants and the results of fire risk studies that have been completed over the last 17 years, we can conclude that internal fires in nuclear power plants can be an important contributor to plant risk. Methods and data are available to quantify the fire risk. These methods and data have been subjected to a series of reviews and detailed scrutiny and have been applied to a large number of plants. There is no doubt that we do not know everything about fire and its impact on a nuclear power plants. However, this lack of knowledge or uncertainty can be quantified and can be used in the decision making process. In other words, the methods entail uncertainties and limitations that are not insurmountable and there is little or no basis for the results of a fire risk analysis fail to support a decision process

  13. Motorcoach Fire Safety Analysis.

    2009-07-01

    This purpose of this study was to collect and analyze information from Government, industry, and media sources on the causes, frequency, and severity of motorcoach fires in the U.S., and to identify potential risk reduction measures. The Volpe Center...

  14. The Safety Analysis of Shipborne Ammunition in Fire Environment

    Ren, Junpeng; Wang, Xudong; Yue, Pengfei

    2017-12-01

    The safety of Ammunition has always been the focus of national military science and technology issues. And fire is one of the major safety threats to the ship’s ammunition storage environment, In this paper, Mk-82 shipborne aviation bomb has been taken as the study object, simulated the whole process of fire by using the FDS (Fire Detection System) software. According to the simulation results of FDS, ANSYS software was used to simulate the temperature field of Mk-82 carrier-based aviation bomb under fire environment, and the safety of aviation bomb in fire environment was analyzed. The result shows that the aviation bombs under the fire environment can occur the combustion or explosion after 70s constant cook-off, and it was a huge threat to the ship security.

  15. 49 CFR 238.103 - Fire safety.

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Fire safety. 238.103 Section 238.103..., DEPARTMENT OF TRANSPORTATION PASSENGER EQUIPMENT SAFETY STANDARDS Safety Planning and General Requirements § 238.103 Fire safety. (a) Materials. (1) Materials used in constructing a passenger car or a cab of a...

  16. Fire Safety. Managing School Facilities, Guide 6.

    Department for Education and Employment, London (England). Architects and Building Branch.

    This booklet discusses how United Kingdom schools can manage fire safety and minimize the risk of fire. The guide examines what legislation school buildings must comply with and covers the major risks. It also describes training and evacuation procedures and provides guidance on fire precautions, alarm systems, fire fighting equipment, and escape…

  17. Safety considerations on LPG storage tanks

    Paff, R.

    1993-01-01

    The safety of liquefied petroleum gas (LPG) storage tanks, in refineries, petrochemicals plants, or distribution storage, is an important concern. Some serious accidents in recent years, have highlighted the need for a good safety policy for such equipment. Accidents in LPG storage are mainly due to losses of containment of the LPG. Formation of a cloud can lead to a ''Unconfined Vapor Cloud Explosion'' (UVCE). Liquid leakage can lead to pool fires in the retention area. In some circumstances the heat input of the tank, combined with the loss of mechanical resistance of the steel under high temperature, can lead to a BLEVE ''Boiling Liquid Expanding Vapor Explosion''. It is obvious that such equipment needs a proper design, maintenance and operating policy. The details to be considered are set out. (4 figures). (Author)

  18. The necessity of periodic fire safety review

    Mowrer, D.S.

    1998-01-01

    Effective fire safety requires the coordinated integration of many diverse elements. Clear fire safety objectives are defined by plant management and/or regulatory authorities. Extensive and time-consuming systematic analyses are performed. Fire safety features (both active and passive) are installed and maintained, and administrative programs are established and implemented to achieve the defined objectives. Personnel are rigorously trained. Given the time, effort and monetary resources expended to achieve a specific level of fire safety, conducting periodic assessments to verify that the specified level of fire safety has been achieved and is maintained is a matter of common sense. Periodic fire safety reviews and assessment play an essential role in assuring continual nuclear safety in the world's power plants

  19. Fire safety assessment of tunnel structures

    Gkoumas, Konstantinos; Giuliani, Luisa; Petrini, Francesco

    2011-01-01

    .g. structural and non structural, organizational, human behavior). This is even more truth for the fire safety design of such structures. Fire safety in tunnels is challenging because of the particular environment, bearing in mind also that a fire can occur in different phases of the tunnel’s lifecycle. Plans...... for upgrading fire safety provisions and tunnel management are also important for existing tunnels. In this study, following a brief introduction of issues regarding the above mentioned aspects, the structural performance of a steel rib for a tunnel infrastructure subject to fire is assessed by means...

  20. Impact of fires on nuclear safety

    Skvarka, P.; Zmajkovic, I.

    1990-01-01

    Factors which are relevant with respect to fire hazard are summarized based on Revision 1 of IAEA Safety Guide No. 50-SG-D2, ''Fire Protection in Nuclear Power Plants'', of 1990. They include data acquisition, quantification of fire risks, assessment of adequacy of fire protection measures, modification of the fire protection system proposed. According to the above document, fire hazard analysis should define and document those parts of the fire protection system that must be present in order to secure safe operation of the nuclear power plant. (Z.M.). 2 appendices, 4 refs

  1. Fire precautions at petroleum refineries and bulk storage installations

    1993-10-01

    Topics covered in this Code of Practice include petroleum products and combustion, site evaluation for fire defence, and fire prevention, protection, detection, systems, fighting, and fire fighting facilities in storage areas. Appendices cover legal requirements and enforcement arrangements, application rates for fire water and foam, codes of practice, flammable limits of petroleum compounds, flash points and spontaneous ignition temperatures and classification of fires. (UK)

  2. Fire hazard analysis for the fuel supply shutdown storage buildings

    REMAIZE, J.A.

    2000-01-01

    The purpose of a fire hazards analysis (FHA) is to comprehensively assess the risk from fire and other perils within individual fire areas in a DOE facility in relation to proposed fire protection so as to ascertain whether the objectives of DOE 5480.7A, Fire Protection, are met. This Fire Hazards Analysis was prepared as required by HNF-PRO-350, Fire Hazards Analysis Requirements, (Reference 7) for a portion of the 300 Area N Reactor Fuel Fabrication and Storage Facility

  3. Behavior based safety approach towards fire

    Suresh Kumar, R.

    2009-01-01

    The behavior of the individual who notice fire first is very important because it affect the safety of all occupants of the area. Human behavior on fire depends on variables of the buildings in which fire occurs and by the appearance of the fire when it is detected. Altruistic behavior of human being will help to handle the critical conditions due to fire emergencies. NPCIL have developed a culture of systematic approach to safeguard men and materials from fire by training and awareness. In our Nuclear Power Plants, we have an effective plan and system to test the plans. In each emergency exercises, the behavior of individuals will be monitored and recorded

  4. Fire Safety Trianing in Health Care Institutions.

    American Hospital Association, Chicago, IL.

    The manual details the procedures to be followed in developing and implementing a fire safety plan. The three main steps are first, to organize; second, to set up a procedure and put it in writing; and third, to train and drill employees and staff. Step 1 involves organizing a safety committee, appointing a fire marshall, and seeking help from…

  5. Fire Safety Design of Wood Structures

    Hertz, Kristian Dahl

    2006-01-01

    Lecture Notes on Fire Safety Design of Wood Structures including charring of wood and load bearing capacity of beams, columns, and connections.......Lecture Notes on Fire Safety Design of Wood Structures including charring of wood and load bearing capacity of beams, columns, and connections....

  6. Fire safety requirements for electrical cables towards nuclear reactor safety

    Raju, M.R.

    2002-01-01

    Full text: Electrical power supply forms a very important part of any nuclear reactor. Power supplies have been categorized in to class I, II, III and IV from reliability point. The safety related equipment are provided with highly reliable power supply to achieve the safety of very high order. Vast network of cables in a nuclear reactor are grouped and segregated to ensure availability of power to at least one group under all anticipated occurrences. Since fire can result in failures leading to unavailability of power caused by common cause, both passive and active fire protection methods are adopted in addition to fire detection system. The paper describes the requirement for passive fire protection to electrical cables viz. fire barrier and fire breaks. The paper gives an account of the tests required to standardize the products. Fire safety implementation for cables in research reactors is described

  7. 29 CFR 1915.502 - Fire safety plan.

    2010-07-01

    ... implement a written fire safety plan that covers all the actions that employers and employees must take to ensure employee safety in the event of a fire. (See Appendix A to this subpart for a Model Fire Safety... safety plan for their employees, and this plan must comply with the host employer's fire safety plan. ...

  8. Fire safety in atomic power plants

    Kench, R.L.; British Insurance

    1988-01-01

    The main reactor types are described briefly - Magnox, advanced gas cooled, pressurized water and fast reactors. Fire risks exist at fuel stores and spent fuel storage facilities. Simple fire prevention measures are suggested. Solid radioactive wastes can also be combustible. Various fire prevention measures for the different storage methods, eg compaction, are given. Gaseous and liquid wastes are also considered. The main types of reactor accident are described and the causes of four incidents - at Chernobyl, Windscale, Brownsferry and Three Mile Island, are examined. (U.K.)

  9. How to increase fire safety in buildings: Fire safety engineering

    Herpen, van R.A.P. (Ruud)

    2011-01-01

    Fire means beside direct (financial)damage often far more indirect costs caused by interruption of operations and loss in sales, market share, property and,in the worst case people can get injured or even get killed (on average around80 persons a year). Fire in buildings is clearly a disaster and

  10. Spent fuel storage criticality safety

    Amin, E M; Elmessiry, A M [National center of nuclear safety and radiation control atomic energy authority, (Egypt)

    1995-10-01

    The safety aspects of the spent fuel storage pool of the Egyptian test and research reactor one (ET-R R-1) has to be assessed as part of a general overall safety evaluation to be included in a safety analysis report (SAR) for this reactor. The present work treats the criticality safety of the spent fuel storage pool. Conservative calculations based on using fresh fuel has been performed, as well as less conservative using burned fuel. The calculations include cross library generation for burned and fresh fuel for the ET-R R-1 fuel type. The WIMS-D 4 code has been used in library generation and burn up calculation the critically calculations are performed using the one dimensional transport code (ANISN) and the two dimensional diffusion code (DIXY2). The possibility of increasing the storage efficiency either by insertion of absorber sheets of soluble boron salts or by reduction of fuel rod separation has been studied. 8 figs., 2 tabs.

  11. Spent fuel storage criticality safety

    Amin, E.M.; Elmessiry, A.M.

    1995-01-01

    The safety aspects of the spent fuel storage pool of the Egyptian test and research reactor one (ET-R R-1) has to be assessed as part of a general overall safety evaluation to be included in a safety analysis report (SAR) for this reactor. The present work treats the criticality safety of the spent fuel storage pool. Conservative calculations based on using fresh fuel has been performed, as well as less conservative using burned fuel. The calculations include cross library generation for burned and fresh fuel for the ET-R R-1 fuel type. The WIMS-D 4 code has been used in library generation and burn up calculation the critically calculations are performed using the one dimensional transport code (ANISN) and the two dimensional diffusion code (DIXY2). The possibility of increasing the storage efficiency either by insertion of absorber sheets of soluble boron salts or by reduction of fuel rod separation has been studied. 8 figs., 2 tabs

  12. Hotel and Motel Fire Safety Project - USFA

    Department of Homeland Security — Provides a listing of properties compliant with the requirements of the Hotel and Motel Fire Safety Act of 1990. Users may search for compliant properties and submit...

  13. Safety considerations for compressed hydrogen storage systems

    Gleason, D.

    2006-01-01

    An overview of the safety considerations for various hydrogen storage options, including stationary, vehicle storage, and mobile refueling technologies. Indications of some of the challenges facing the industry as the demand for hydrogen fuel storage systems increases. (author)

  14. Fire Hazards Analysis for the 200 Area Interim Storage Area

    JOHNSON, D.M.

    2000-01-01

    This documents the Fire Hazards Analysis (FHA) for the 200 Area Interim Storage Area. The Interim Storage Cask, Rad-Vault, and NAC-1 Cask are analyzed for fire hazards and the 200 Area Interim Storage Area is assessed according to HNF-PRO-350 and the objectives of DOE Order 5480 7A. This FHA addresses the potential fire hazards associated with the Interim Storage Area (ISA) facility in accordance with the requirements of DOE Order 5480 7A. It is intended to assess the risk from fire to ensure there are no undue fire hazards to site personnel and the public and to ensure property damage potential from fire is within acceptable limits. This FHA will be in the form of a graded approach commensurate with the complexity of the structure or area and the associated fire hazards

  15. Large Scale Experiments on Spacecraft Fire Safety

    Urban, David L.; Ruff, Gary A.; Minster, Olivier

    2012-01-01

    -based microgravity facilities or has been limited to very small fuel samples. Still, the work conducted to date has shown that fire behaviour in low-gravity is very different from that in normal-gravity, with differences observed for flammability limits, ignition delay, flame spread behaviour, flame colour and flame......Full scale fire testing complemented by computer modelling has provided significant knowhow about the risk, prevention and suppression of fire in terrestrial systems (cars, ships, planes, buildings, mines, and tunnels). In comparison, no such testing has been carried out for manned spacecraft due...... to the complexity, cost and risk associ-ated with operating a long duration fire safety experiment of a relevant size in microgravity. Therefore, there is currently a gap in knowledge of fire behaviour in spacecraft. The entire body of low-gravity fire research has either been conducted in short duration ground...

  16. Large Scale Experiments on Spacecraft Fire Safety

    Urban, David; Ruff, Gary A.; Minster, Olivier; Fernandez-Pello, A. Carlos; Tien, James S.; Torero, Jose L.; Legros, Guillaume; Eigenbrod, Christian; Smirnov, Nickolay; Fujita, Osamu; hide

    2012-01-01

    Full scale fire testing complemented by computer modelling has provided significant knowhow about the risk, prevention and suppression of fire in terrestrial systems (cars, ships, planes, buildings, mines, and tunnels). In comparison, no such testing has been carried out for manned spacecraft due to the complexity, cost and risk associated with operating a long duration fire safety experiment of a relevant size in microgravity. Therefore, there is currently a gap in knowledge of fire behaviour in spacecraft. The entire body of low-gravity fire research has either been conducted in short duration ground-based microgravity facilities or has been limited to very small fuel samples. Still, the work conducted to date has shown that fire behaviour in low-gravity is very different from that in normal gravity, with differences observed for flammability limits, ignition delay, flame spread behaviour, flame colour and flame structure. As a result, the prediction of the behaviour of fires in reduced gravity is at present not validated. To address this gap in knowledge, a collaborative international project, Spacecraft Fire Safety, has been established with its cornerstone being the development of an experiment (Fire Safety 1) to be conducted on an ISS resupply vehicle, such as the Automated Transfer Vehicle (ATV) or Orbital Cygnus after it leaves the ISS and before it enters the atmosphere. A computer modelling effort will complement the experimental effort. Although the experiment will need to meet rigorous safety requirements to ensure the carrier vehicle does not sustain damage, the absence of a crew removes the need for strict containment of combustion products. This will facilitate the possibility of examining fire behaviour on a scale that is relevant to spacecraft fire safety and will provide unique data for fire model validation. This unprecedented opportunity will expand the understanding of the fundamentals of fire behaviour in spacecraft. The experiment is being

  17. 40 CFR 30.18 - Hotel and motel fire safety.

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Hotel and motel fire safety. 30.18... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 30.18 Hotel and motel fire safety. The Hotel and Motel Fire Safety Act of 1990 (Public Law 101-391) establishes a number of fire...

  18. 34 CFR 668.49 - Institutional fire safety policies and fire statistics.

    2010-07-01

    ... 34 Education 3 2010-07-01 2010-07-01 false Institutional fire safety policies and fire statistics... fire statistics. (a) Additional definitions that apply to this section. Cause of fire: The factor or...; however, it does not include indirect loss, such as business interruption. (b) Annual fire safety report...

  19. Examination of alternatives to upgrade fire safety in operating NPPs

    Park, J. H.; Jung, I. S.

    2003-01-01

    For the Kori unit 2,3,4, Younggwang 1,2 and Ulchin 1,2 fire protection vulnerabilities and further improvement items are investigated. The most major problem is that those plants do not have plant-specific Fire Hazard Analysis Report. To improve fire safety of those plants, their own Fire Hazard Analysis should be proceed at first. Then, according to results of Fire Hazard Analysis, fire protection improvement program should be implemented. For the assurance of long term fire safety, result of Fire Hazard Analysis should be incorporated in the FSAR and periodically reviewed the impact of design change to fire safety

  20. Large-Scale Spacecraft Fire Safety Tests

    Urban, David; Ruff, Gary A.; Ferkul, Paul V.; Olson, Sandra; Fernandez-Pello, A. Carlos; T'ien, James S.; Torero, Jose L.; Cowlard, Adam J.; Rouvreau, Sebastien; Minster, Olivier; hide

    2014-01-01

    An international collaborative program is underway to address open issues in spacecraft fire safety. Because of limited access to long-term low-gravity conditions and the small volume generally allotted for these experiments, there have been relatively few experiments that directly study spacecraft fire safety under low-gravity conditions. Furthermore, none of these experiments have studied sample sizes and environment conditions typical of those expected in a spacecraft fire. The major constraint has been the size of the sample, with prior experiments limited to samples of the order of 10 cm in length and width or smaller. This lack of experimental data forces spacecraft designers to base their designs and safety precautions on 1-g understanding of flame spread, fire detection, and suppression. However, low-gravity combustion research has demonstrated substantial differences in flame behavior in low-gravity. This, combined with the differences caused by the confined spacecraft environment, necessitates practical scale spacecraft fire safety research to mitigate risks for future space missions. To address this issue, a large-scale spacecraft fire experiment is under development by NASA and an international team of investigators. This poster presents the objectives, status, and concept of this collaborative international project (Saffire). The project plan is to conduct fire safety experiments on three sequential flights of an unmanned ISS re-supply spacecraft (the Orbital Cygnus vehicle) after they have completed their delivery of cargo to the ISS and have begun their return journeys to earth. On two flights (Saffire-1 and Saffire-3), the experiment will consist of a flame spread test involving a meter-scale sample ignited in the pressurized volume of the spacecraft and allowed to burn to completion while measurements are made. On one of the flights (Saffire-2), 9 smaller (5 x 30 cm) samples will be tested to evaluate NASAs material flammability screening tests

  1. Fire propagation through arrays of solid-waste storage drums

    Smith, S.T.; Hinkle, A.W.

    1995-01-01

    The extent of propagation of a fire through drums of solid waste has been an unresolved issue that affects all solid-waste projects and existing solid-waste storage and handling facilities at the Hanford site. The issue involves the question of how many drums of solid waste within a given fire area will be consumed in a design-basis fire for given parameters such as drum loading, storage arrays, initiating events, and facility design. If the assumption that all drums of waste within a given fire area are consumed proves valid, then the construction costs of solid waste facilities may be significantly increased

  2. The influence of sodium fires on LMFBRs safety analysis

    Justin, F [DSN/Centre de Fontenay-aux-Roses, Fontenay-aux-Roses (France)

    1979-03-01

    In a sodium cooled reactor, sodium fires are accidental conditions to be taken into account in safety analysis. For the various sodium categories, fire conditions, associated risks, safety analysis objectives and detailed corresponding issues are indicated, An experimental research program can be deduced from these considerations. This report covers the following: safety analysis methodology; primary sodium fires; secondary sodium fires; auxiliary sodium fires, and related experimental research programs.

  3. The influence of sodium fires on LMFBRs safety analysis

    Justin, F.

    1979-01-01

    In a sodium cooled reactor, sodium fires are accidental conditions to be taken into account in safety analysis. For the various sodium categories, fire conditions, associated risks, safety analysis objectives and detailed corresponding issues are indicated, An experimental research program can be deduced from these considerations. This report covers the following: safety analysis methodology; primary sodium fires; secondary sodium fires; auxiliary sodium fires, and related experimental research programs

  4. Different design approaches to structural fire safety

    Giuliani, Luisa; Budny, I.

    2013-01-01

    -priori evaluate which design is the safest or the most economical one: a punctual analysis of the different aspects and a comparison of the resulting designs is therefore of interest and is presented in this paper with reference to the case study considered.The third approach refers instead to a performance......-based fire design of the structure(PBFD), where safety goals are explicitly defined and a deeper knowledge of the structural response to fire effects can be achieved, for example with the avail of finite element analyses (FEA). On the other hand, designers can’t follow established procedures when undertaking...... such advanced investigations, which are generally quite complex ones, due to the presence of material degradation and large displacements induced by fire, as well as the possible triggering of local mechanism in the system. An example of advanced investigations for fire design is given in the paper...

  5. Fire Safety During the Holiday Season | Poster

    Winter is here, and that means holiday decorations, a warm hearth, and (hopefully) plenty of homecooked meals. Unfortunately, winter also brings numerous fire hazards both at work and around the house. This year, as you shop, decorate, and celebrate, keep these safety tips in mind to ensure a safe and enjoyable holiday season.

  6. Enhanced safety in the storage of fissile materials

    Williams, G.E.; Alvares, N.J.

    1978-01-01

    An inexpensive boron-loaded liner of epoxy resin for fissile-material storage containers was developed that can be easily fabricated of readily available, low-cost materials. Computer calculations indicate reactivity will be reduced substantially if this neutron-absorbing liner is added to containers in a typical storage array. These calculations compare favorably with neutron-attenuation experiments with thermal and fission neutron spectra, and tests at the Fire Test Facility indicate the epoxy resin will survive extreme environmental and accident conditions. The fire-resistant and insulating properties of the epoxy-resin liner further augment its ability to protect fissile materials. Boron-loaded epoxy resin is adaptable to many tasks but is particularly useful for providing enhanced criticality safety in the packaging and storage of fissile materials

  7. Nuclear power plants: a unique challenge to fire safety

    Nowlen, S.P.

    1992-01-01

    The evaluation of fire safety in a nuclear power plant must include the consideration of the impact of a fire on the operability of plant safety equipment and systems. This issue is not typical of the life safety and property protection issues which dominate traditional fire safety concerns. This paper provides a general discussion of the issue of nuclear power plant fire safety as it currently exists in the USA. Included is a discussion of the past history of nuclear power plant fire events, the development of nuclear industry specific fire safety guidelines, the adverse experience associated with the inadvertent operation of fire suppression systems, and the anticipated direction of fire safety requirements for future reactor designs in the USA. (Author)

  8. Fire safety assessment for the fire areas of the nuclear power plant using fire model CFAST

    Lee, Yoon Hwan; Yang, Joon Eon; Kim, Jong Hoon

    2005-03-01

    Now the deterministic analysis results for the cable integrity is not given in case of performing the fire PSA. So it is necessary to develop the assessment methodology for the fire growth and propagation. This document is intended to analyze the peak temperature of the upper gas layer using the fire modeling code, CFAST, to evaluate the integrity of the cable located on the dominant pump rooms, and to assess the CCDP(Conditional Core Damage Probability) using the results of the cable integrity. According to the analysis results, the cable integrity of the pump rooms is maintained and CCDP is reduced about two times than the old one. Accordingly, the fire safety assessment for the dominant fire areas using the fire modeling code will capable to reduce the uncertainty and to develop a more realistic model

  9. Topology optimization for simplified structural fire safety

    Madsen, Søren; Lange, Nis P.; Giuliani, Luisa

    2016-01-01

    Topology optimization is applied in an idealized structural fire safety model, where the minimum compliance problem is constrained by temperature-controlled structural degradation. The constraint ensures a certain structural stiffness after a prescribed time. As this time period is extended......, resulting optimized topologies tend to become thicker or introduce redundant members that can take over when structural parts near the origin of the fire lose their load carrying capability. Hence, the structural degradation model acts as an erosion operator on the topology and indirectly enforces a minimum...

  10. Lessons learned from IAEA fire safety missions

    Lee, S.P.

    1998-01-01

    The IAEA has conducted expert missions to evaluate fire safety at the following nuclear power plants: the Zaporozhe plant in the Ukraine, the Borselle plant in the Netherlands, the Medzamor plant in Armenia, the Karachi plant in Pakistan, the Temelin plant in the Czech Republic, and the Laguna Verde plant in Mexico. The scope of these missions varied in subject and depth. The teams sent from the IAEA consisted of external fire experts and IAEA staff. All the missions were of great use to the host countries. The participating experts also benefited significantly. A summary of the missions and their findings is given. (author)

  11. Fire hazards analysis for W-413, West Area Tank Farm Storage and Staging Facility

    Huckfeldt, R.A.; Lott, D.T.

    1994-01-01

    In accordance with DOE Order 5480.7A, a Fire Hazards Analysis must be performed for all new facilities. The purpose of the analysis is to comprehensively assess the risk from fire within individual fire areas in relation to proposed fire protection so as to ascertain whether the fire protection objectives of the Order are met. The Order acknowledges a graded approach commensurate with the hazards involved. Tank Farms Operations must sore/stage material and equipment such as pipes, fittings, conduit, instrumentation and others related items until work packages are ready to work. Consumable materials, such as nut, bolts and welding rod, are also requires to be stored for routine and emergency work. Connex boxes and open storage is currently used for much of the storage because of the limited space at and 272WA. Safety issues based on poor housekeeping and material deteriorating due to weather damage has resulted from this inadequate storage space. It has been determined that a storage building in close proximity to the Tank Farm work force would be cost effective. This facility is classified as a safety class 4 building

  12. Investigation of Fire Safety Awareness and Management in Mall

    Abdul Rahim N.

    2014-03-01

    Full Text Available In spite of having sufficient fire safety system installed in buildings, the incidence of fire hazard becomes the furthermost and supreme threat to health and safety, as well as property to any community. In order to make sure that the safety of the building and its users, the fundamental features depends on the fire precaution system and equipment which should be according to the standard requirements. Nevertheless, the awareness on fire safety could necessarily alleviate the damages or rate of fatality during the event of fire. This paper presents the results on the investigation of fire safety awareness and management, concentrating on shopping mall. The endeavour of this study is to explore the level of fire safety knowledge of the users in the mall, and to study the effectiveness level of fire safety management in a mall. From the study, public awareness is highly related to understanding human behaviour and their personal background. The respondents’ levels of awareness are rather low, which reflects on their poor action when facing emergency situation during fire. The most effective methods identified to improve the awareness and effectiveness of fire safety level is through involvement in related fire safety programmes, distribution of pamphlets or brochures on fire safety and appointing specific personnel for Emergency Response Team in the mall.

  13. 78 FR 70076 - Aging Management of Internal Surfaces, Fire Water Systems, Atmospheric Storage Tanks, and...

    2013-11-22

    ... Systems, Atmospheric Storage Tanks, and Corrosion Under Insulation AGENCY: Nuclear Regulatory Commission... Internal Surfaces, Fire Water Systems, Atmospheric Storage Tanks, and Corrosion Under Insulation.'' This LR... related to internal surface aging effects, fire water systems, atmospheric storage tanks, and corrosion...

  14. French Approach for Long Term Storage Safety

    Marciano, Jacob; Carreton, Jean-Pierre; Lizot, Marie Therese; Lhomme, Veronique

    2014-01-01

    IRSN presents its statement regarding long-term storage facilities; in France, the regulatory documents do not define the long term duration. The storage facility lifetime can only be appreciated according to the needs and materials stored therein. However, the magnitude of the long-term can be estimated at a few hundred years compared to a few decades for current storage. Usually, in France, construction of storage facilities is driven from the necessity various necessities, linked to the management of radioactive material (eg spent fuel) and to the management of radioactive waste. Because of the variety of 'stored materials and objects' (fission product solutions, plutonium oxide powders, activated solids, drums containing technological waste, spent fuel...), a great number of storage facility design solutions have been developed (surface, subsurface areas, dry or wet conditions...) in the World. After describing the main functions of a storage facility, IRSN displays the safety principles and the associated design principles. The specific design principles applied to particular storage (dry or wet spent fuel storage, depleted uranium or reprocessed uranium storage, plutonium storage, waste containing tritium storage, HLW and ILLW storage...) are also presented. Finally, the concerns due to the long-term duration storage and related safety assessment are developed. After discussing these issues, IRSN displays its statement. The authorization procedures governing the facility lifetime are similar to those of any basic nuclear installation, the continuation of the facility operation remaining subject to periodic safety reviews (in France, every 10 years). The applicant safety cases have to show, that the safety requirements are always met; this requires, at minimum, to take into account at the design stage, comfortable design margins. (author)

  15. Fire-safety engineering and performance-based codes

    Sørensen, Lars Schiøtt

    project administrators, etc. The book deals with the following topics: • Historical presentation on the subject of fire • Legislation and building project administration • European fire standardization • Passive and active fire protection • Performance-based Codes • Fire-safety Engineering • Fundamental......Fire-safety Engineering is written as a textbook for Engineering students at universities and other institutions of higher education that teach in the area of fire. The book can also be used as a work of reference for consulting engineers, Building product manufacturers, contractors, building...... thermodynamics • Heat exchange during the fire process • Skin burns • Burning rate, energy release rate and design fires • Proposal to Risk-based design fires • Proposal to a Fire scale • Material ignition and flame spread • Fire dynamics in buildings • Combustion products and toxic gases • Smoke inhalation...

  16. 46 CFR 62.35-15 - Fire safety.

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Fire safety. 62.35-15 Section 62.35-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING VITAL SYSTEM AUTOMATION Requirements for Specific Types of Automated Vital Systems § 62.35-15 Fire safety. (a) All required fire pump...

  17. Building safety and human behaviour in fire: A literature review

    Kobes, M.; Helsloot, I.; de Vries, B.; Post, J.

    2010-01-01

    The most crucial aspect of a building's safety in the face of fire is the possibility of safe escape. An important precondition is that its fire safety facilities enable independent and adequate fire response performances by the building's occupants. In practice, it appears that the measures

  18. Radioactive wastes. Safety of storage facilities

    Devillers, Ch.

    2001-01-01

    A radioactive waste storage facility is designed in a way that ensures the isolation of wastes with respect to the biosphere. This function comprises the damping of the gamma and neutron radiations from the wastes, and the confinement of the radionuclides content of the wastes. The safety approach is based on two time scales: the safety of the insulation system during the main phase of radioactive decay, and the assessment of the radiological risks following this phase. The safety of a surface storage facility is based on a three-barrier concept (container, storage structures, site). The confidence in the safety of the facility is based on the quality assurance of the barriers and on their surveillance and maintenance. The safety of a deep repository will be based on the site quality, on the design and construction of structures and on the quality of the safety demonstration. This article deals with the safety approach and principles of storage facilities: 1 - recall of the different types of storage facilities; 2 - different phases of the life of a storage facility and regulatory steps; 3 - safety and radiation protection goals (time scales, radiation protection goals); 4 - safety approach and principles of storage facilities: safety of the isolation system (confinement system, safety analysis, scenarios, radiological consequences, safety principles), assessment of the radiation risks after the main phase of decay; 5 - safety of surface storage facilities: safety analysis of the confinement system of the Aube plant (barriers, scenarios, modeling, efficiency), evaluation of radiological risks after the main phase of decay; experience feedback of the Manche plant; variants of surface storage facilities in France and abroad (very low activity wastes, mine wastes, short living wastes with low and average activity); 6 - safety of deep geological disposal facilities: legal framework of the French research; international context; safety analysis of the confinement system

  19. Safety assessment for spent fuel storage facilities

    1994-01-01

    This Safety Practice has been prepared as part of the IAEA's programme on the safety assessment of interim spent fuel storage facilities which are not an integral part of an operating nuclear power plant. This report provides general guidance on the safety assessment process, discussing both deterministic and probabilistic assessment methods. It describes the safety assessment process for normal operation and anticipated operational occurrences and also related to accident conditions. 10 refs, 2 tabs

  20. Transport fire safety engineering in the European Union - project TRANSFEU

    Jolanta Maria RADZISZEWSKA-WOLIŃSKA

    2011-01-01

    Full Text Available Article presents European Research project (of FP7-SST-2008-RTD-1 for Surface transportation TRANSFEU. Projects undertakes to deliver both a reliable toxicity measurement methodology and a holistic fire safety approach for all kind of surface transport. It bases on a harmonized Fire Safety Engineering methodology which link passive fire security with active fire security mode. This all embracing system is the key to attain optimum design solutions in respect to fire safety objectives as an alternative to the prescriptive approach. It will help in the development of innovative solutions (design and products used for the building of the surface transport which will better respect the environment.In order to reach these objectives new toxicity measurement methodology and related classification of materials, new numerical fire simulation tools, fire test methodology (laboratory and full scale and a decisive tool to optimize or explore new design in accordance to the fire safety requirements will be developed.

  1. Safety design guides for fire protection for CANDU 9

    Lee, Duk Su; Chang, Woo Hyun; Lee, Nam Young; A. C. D. Wright

    1996-03-01

    This safety design guide establishes design requirements to ensure the radiological risk to the public due to fire is acceptable and operating personnel are adequately protected from the hazards of fires. This safety design guide also specifies the safety criteria for fire protection to be applied to mitigate fires and recommends the fire protection program to be established to initiate, coordinate and document the design activities associated with fire protection. The requirements for fire protection outlined in this safety design guide shall be satisfied in the design stage and the change status of the regulatory requirements, code and standards should be traced and incorporated into this safety design guide accordingly. 1 fig., (Author) .new

  2. Efficacy of water spray protection against propane and butane jet fires impinging on LPG storage tanks

    Shirvill, L.C. [Shell Global Solutions (UK), Chester (United Kingdom)

    2004-03-01

    Liquefied petroleum gas (LPG) storage tanks are often provided with water sprays to protect them in the event of a fire. This protection has been shown to be effective in a hydrocarbon pool fire but uncertainties remained regarding the degree of protection afforded in a jet fire resulting from a liquid or two-phase release of LPG. Two projects, sponsored by the Health and Safety Executive, have been undertaken to study, at full scale, the performance of a water spray system on an empty 13 tonne LPG vessel under conditions of jet fire impingement from nearby releases of liquid propane and butane. The results showed that a typical water deluge system found on an LPG storage vessel cannot be relied upon to maintain a water film over the whole vessel surface in an impinging propane or butane jet fire scenario. The deluge affects the fire itself, reducing the luminosity and smoke, resulting in a lower rate of wall temperature rise at the dry patches, when compared with the undeluged case. The results of these studies will be used by the HSE in assessing the risk of accidental fires on LPG installations leading to boiling liquid expanding vapour explosion (BLEVE) incidents. (Author)

  3. Safety assessment of outdoor live fire range

    NONE

    1989-05-01

    The following Safety Assessment (SA) pertains to the outdoor live fire range facility (LFR). The purpose of this facility is to supplement the indoor LFR. In particular it provides capacity for exercises that would be inappropriate on the indoor range. This SA examines the risks that are attendant to the training on the outdoor LFR. The outdoor LFR used by EG&G Mound is privately owned. It is identified as the Miami Valley Shooting Grounds. Mondays are leased for the exclusive use of EG&G Mound.

  4. Advanced analysis and design for fire safety of steel structures

    Li, Guoqiang

    2013-01-01

    Advanced Analysis and Design for Fire Safety of Steel Structures systematically presents the latest findings on behaviours of steel structural components in a fire, such as the catenary actions of restrained steel beams, the design methods for restrained steel columns, and the membrane actions of concrete floor slabs with steel decks. Using a systematic description of structural fire safety engineering principles, the authors illustrate the important difference between behaviours of an isolated structural element and the restrained component in a complete structure under fire conditions. The book will be an essential resource for structural engineers who wish to improve their understanding of steel buildings exposed to fires. It is also an ideal textbook for introductory courses in fire safety for master’s degree programs in structural engineering, and is excellent reading material for final-year undergraduate students in civil engineering and fire safety engineering. Furthermore, it successfully bridges th...

  5. Safety guide on fire protection in nuclear power plants

    1976-01-01

    The purpose of the Safety Guide is to give specific design and operational guidance for protection from fire and explosion in nuclear power plants, based on the general guidance given in the relevant sections of the 'Safety Code of Practice - Design' and the 'Safety Code of Practice - Operation' of the International Atomic Energy Agency. The guide will confine itself to fire protection of safety systems and items important to safety, leaving the non-safety matters of fire protection in nuclear power plants to be decided upon the basis of the various available national and international practices and regulations. (HP) [de

  6. Fire safety in the atomic age

    Whitman, L.E.

    1980-01-01

    This nontechnical review of radiation hazards acquaints those faced with radiation fire-safety problems (firemen, plant safety personnel, technicians, and others) with what the hazards are, where they may be found, and how to deal with them. It removes unnecessary fears and misconceptions by giving a picture of radiation as something that is neither to be feared nor ignored, but rather something that can be lived with safely. Since all radioactive materials emit energy that has the power to damage living tissue, those involved with fire protection who might come into contact with such materials must understand both the real dangers from a variety of radiation exposures, and the safest, most-effective ways to avert danger to themselves and others. Whitman discusses in detail the potential hazards, from contamination from radioactive waste to transportation of radioactive materials, from nuclear power plants to radiation machinery and nuclear weapons. He presents the basic facts and includes practical problems to be solved. 14 references, 65 figures

  7. National and international standards and recommendations on fire protection and fire safety assessment

    Berg, H.P.

    2007-01-01

    Experience feedback from events in nuclear facilities worldwide has shown that fire can represent a safety significant hazard. Thus, the primary objectives of fire protection programmes are to minimize both the probability of occurrence and the consequences of a fire. The regulator body expects that the licensees justify their arrangements for identifying how fires can occur and spread, assess the vulnerability of plant equipment and structures, determine how the safe operation of a plant is affected, and introduce measures to prevent a fire hazard from developing and propagating as well as to mitigate its effects in case the fire cannot be prevented. For that purpose usually a comprehensive regulatory framework for fire protection has been elaborated, based on national industrial regulations, nuclear specific regulations as well as international recommendations or requirements. Examples of such national and international standards and recommendations on fire protection and fire safety assessment as well as ongoing activities in this field are described. (orig.)

  8. Fire safety study of Dodewaard and Borssele nuclear power plants

    1988-03-01

    From the nuclear and conventional fire safety audits of both Dutch nuclear power plants performed under supervision of the Nuclear Safety Inspectorate and the Inspectorate for the Fire Services it turns out that the fire safety is sufficient however amenable for improvement. Besides a detailed description of the method of examination, the study 'Fire Safety' contains the results of the audit and 14 respectively 15 recommendations for improvement of the fire safety in Dodewaard and Borssele. The suggested recommendations which are applicable to both power plants are the following: fire fighting training for operators and guards, a complete emergency ventilation system of the control room, increase in the number of detectors and alarms, an increase in the quantity of water available for high-pressure fire fighting, improvement of fire barriers between several redundancies of nuclear safety systems, an investigation and possible improvement of the heat and radiation protection offered by presently used fire fighting suits. For Dodewaard a closed emergency staircase in the reactor building (secondary containment) is deemed necessary for personnel emergency escape routes and continued fire fighting if required

  9. Fire protection and safety in working with sodium. Pt. 2

    Foerster, K.; Kremer, K.H.; Wolf, J.

    1978-01-01

    The use of sodium as a heat transfer medium in nuclear plant and the associated development of sodium technology caused the requirement for adapting fire and safety precautions to new conditions of dealing with this liquid. The comparison in the first part of this article of the properties of sodium with those of petrol clarified the different fire characteristics of sodium compared to many other combustible materials and the effects of fires which differ from conventional fires. Based on this, measures for fire precautions and for safety of personnel are introduced. (orig.) [de

  10. Safety tests carried out at Cadarache. Sodium fires

    Fruchard, M.

    1976-01-01

    Safety test on sodium fires developed at the Cadarache Nuclear Centre by the Department of Nuclear Safety, section of safety experiments on radioactivity transfer are conducted in two main directions: analysis of the behavior and thermodynamic consequences of accidental fires, working on the basis of typical experimental results; research and development of methods and equipment to control and if possible extinguish these fires. The most important part of this programme is concerned with the sodium pool fires which would result from the failure of a secondary coolant circuit pipe [fr

  11. Appraisal of Fire Safety Management Systems at Educational Buildings

    Nadzim N.

    2014-01-01

    Full Text Available Educational buildings are one type of government asset that should be protected, and they play an important role as temporary communal meeting places for children, teachers and communities. In terms of management, schools need to emphasize fire safety for their buildings. It is well known that fires are not only a threat to the building’s occupants, but also to the property and the school environment. A study on fire safety management has been carried out on schools that have recently experienced fires in Penang. From the study, it was found that the school buildings require further enhancement in terms of both active and passive fire protection systems. For instance, adequate fire extinguishers should be provided to the school and the management should inspect and maintain fire protection devices regularly. The most effective methods to increase the level of awareness on fire safety are by organizing related programs on the management of fire safety involving all staff, teachers and students, educational talks on the dangers of fire and important actions to take in the event of an emergency, and, lastly, to appoint particular staff to join the management safety team in schools.

  12. Evaluation of fire probabilistic safety assessment for a PWR plant

    Wu, C.H.; Lin, T.J.; Kao, T.M.

    2001-01-01

    The internal fire analysis of the level 1 power operation probability safety assessment (PSA) for Maanshan (PWR) Nuclear Power Plant (MNPP) was updated. The fire analysis adopted a scenario-based PSA approach to systematically evaluate fire and smoke hazards and their associated risk impact to MNPP. The result shows that the core damage frequency (CDF) due to fire is about six times lower than the previous one analyzed by the Atomic Energy Council (AEC), Republic of China in 1987. The plant model was modified to reflect the impact of human events and recovery actions during fire. Many tabulated EXCEL spread-sheets were used for evaluation of the fire risk. The fire-induced CDF for MNPP is found to be 2.1 E-6 per year in this study. The relative results of the fire analysis will provide the bases for further risk-informed fire protection evaluation in the near future. (author)

  13. ACRR fuel storage racks criticality safety analysis

    Bodette, D.E.; Naegeli, R.E.

    1997-10-01

    This document presents the criticality safety analysis for a new fuel storage rack to support modification of the Annular Core Research Reactor for production of molybdenum-99 at Sandia National Laboratories, Technical Area V facilities. Criticality calculations with the MCNP code investigated various contingencies for the criticality control parameters. Important contingencies included mix of fuel element types stored, water density due to air bubbles or water level for the over-moderated racks, interaction with existing fuel storage racks and fuel storage holsters in the fuel storage pool, neutron absorption of planned rack design and materials, and criticality changes due to manufacturing tolerances or damage. Some limitations or restrictions on use of the new fuel storage rack for storage operations were developed through the criticality analysis and are required to meet the double contingency requirements of criticality safety. As shown in the analysis, this system will remain subcritical under all credible upset conditions. Administrative controls are necessary for loading, moving, and handling the storage rack as well as for control of operations around it. 21 refs., 16 figs., 4 tabs

  14. Human Factors in Fire Safety Management and Prevention

    M.A. Othuman Mydin

    2014-07-01

    Full Text Available Fire protection is the study and practice of mitigating the unwanted effects of potentially destructive fires. It involves the study of the behavior, compartmentalization, and investigation of fire and its related emergencies, as well as the research and development, production, testing and application of mitigating systems. Problems still occurred despite of the adequate fire safety systems installed. For most people in high-risk buildings, not all accidents were caused by them. They were more likely to be the victims of a fire that occurred. Besides damaging their properties and belongings, some people were burned to death for not knowing what to do if fire happens in their place. This paper will present the human factors in fire safety management and prevention system.

  15. Analysis of pressurization of plutonium oxide storage vials during a postulated fire

    Laurinat, J.; Kesterson, M.; Hensel, S.

    2015-02-10

    The documented safety analysis for the Savannah River Site evaluates the consequences of a postulated 1000 °C fire in a glovebox. The radiological dose consequences for a pressurized release of plutonium oxide powder during such a fire depend on the maximum pressure that is attained inside the oxide storage vial. To enable evaluation of the dose consequences, pressure transients and venting flow rates have been calculated for exposure of the storage vial to the fire. A standard B vial with a capacity of approximately 8 cc was selected for analysis. The analysis compares the pressurization rate from heating and evaporation of moisture adsorbed onto the plutonium oxide contents of the vial with the pressure loss due to venting of gas through the threaded connection between the vial cap and body. Tabulated results from the analysis include maximum pressures, maximum venting velocities, and cumulative vial volumes vented during the first 10 minutes of the fire transient. Results are obtained for various amounts of oxide in the vial, various amounts of adsorbed moisture, different vial orientations, and different surface fire exposures.

  16. Development of Large-Scale Spacecraft Fire Safety Experiments

    Ruff, Gary A.; Urban, David L.; Fernandez-Pello, A. Carlos

    2013-01-01

    exploration missions outside of low-earth orbit and accordingly, more complex in terms of operations, logistics, and safety. This will increase the challenge of ensuring a fire-safe environment for the crew throughout the mission. Based on our fundamental uncertainty of the behavior of fires in low...... of the spacecraft fire safety risk. The activity of this project is supported by an international topical team of fire experts from other space agencies who conduct research that is integrated into the overall experiment design. The large-scale space flight experiment will be conducted in an Orbital Sciences...

  17. Industrial safety and fire protection during the construction phase

    Zimmer, K.

    1977-01-01

    The questions and problems of industrial safety and fire prevention have to be treated like the activities planning, developing, assembly, etc. This statement is illustrated by statistics of the fire insurance companies, from which it can be seen that the number of fire accidents has decreased but that the damage caused has greatly increased. The sooner the fire prevention and industrial safety measures are integrated in the planning phase, the better for the total costs. Preventive measures that possibly have to be introduced at a later stage are not only generally much more expensive but are also seldom as effective. (orig./HK) [de

  18. Proceedings of the Topical Meeting on the safety of nuclear fuel cycle intermediate storage facilities

    1998-01-01

    The CSNI Working Group on Fuel Cycle Safety held an International Topical Meeting on safety aspects of Intermediate Storage Facilities in Newby Bridge, England, from 28 to 30 October 1997. The main purpose of the meeting was to provide a forum for the exchange of information on the technical issues on the safety of nuclear fuel cycle facilities (intermediate storage). Titles of the papers are: An international view on the safety challenges to interim storage of spent fuel. Interim storage of intermediate and high-level waste in Belgium: a description and safety aspects. Encapsulated intermediate level waste product stores at Sellafield. Safety of interim storage facilities of spent fuel: the international dimension and the IAEA's activities. Reprocessing of irradiated fuel and radwaste conditioning at Belgoprocess site: an overview. Retrieval of wastes from interim storage silos at Sellafield. Outline of the fire and explosion of the bituminization facility and the activities of the investigation committee (STAIJAERI). The fire and explosion incident of the bituminization facility and the lessons learned from the incident. Study on the scenario of the fire incident and related analysis. Study on the scenario of the explosion incident and related analysis. Accident investigation board report on the May 14, 1997 chemical explosion at the plutonium reclamation facility, Hanford site, Richland, Washington. Dry interim storage of spent nuclear fuel elements in Germany. Safe and effective system for the bulk receipt and storage of light water reactor fuel prior to reprocessing. Receiving and storage of glass canisters at vitrified waste storage center of Japan Nuclear Fuel Ltd. Design and operational experience of dry cask storage systems. Sellafield MOX plant; Plant safety design (BNFL). The assessment of fault studies for intermediate term waste storage facilities within the UK nuclear regulatory regime. Non-active and active commissioning of the thermal oxide

  19. German data for risk based fire safety assessment

    Roewekamp, M.; Berg, H.P.

    1998-01-01

    Different types of data are necessary to perform risk based fire safety assessments and, in particular, to quantify the fire event tree considering the plant specific conditions. Data on fire barriers, fire detection and extinguishing, including also data on secondary effects of a fire, have to be used for quantifying the potential hazard and damage states. The existing German database on fires in nuclear power plants (NPPs) is very small. Therefore, in general generic data, mainly from US databases, are used for risk based safety assessments. Due to several differences in the plant design and conditions generic data can only be used as conservative assumptions. World-wide existing generic data on personnel failures in case of fire fighting have only to be adapted to the plant specific conditions inside the NPP to be investigated. In contrary, unavailabilities of fire barrier elements may differ strongly depending on different standards, testing requirements, etc. In addition, the operational behaviour of active fire protection equipment may vary depending on type and manufacturer. The necessity for more detailed and for additional plant specific data was the main reason for generating updated German data on the operational behaviour of active fire protection equipment/features in NPPs to support risk based fire safety analyses being recommended to be carried out as an additional tool to deterministic fire hazard analyses in the frame of safety reviews. The results of these investigations revealed a broader and more realistic database for technical reliability of active fire protection means, but improvements as well as collection of further data are still necessary. (author)

  20. Safety study of fire protection for nuclear fuel cycle facility

    2013-01-01

    Insufficiencies in the fire protection system of the nuclear reactor facilities were pointed out when the fire occurred due to the Niigata prefecture-Chuetsu-oki Earthquake in July, 2007. This prompted the revision of the fire protection safety examination guideline for nuclear reactors as well as commercial guidelines. The commercial guidelines have been endorsed by the regulatory body. Now commercial fire protection standards for nuclear facilities such as the design guideline and the management guideline for protecting fire in the Light Water Reactors (LWRs) are available, however, those to apply to the nuclear fuel cycle facilities such as mixed oxide fuel fabrication facility (MFFF) have not been established. For the improvement of fire protection system of the nuclear fuel cycle facilities, the development of a standard for the fire protection, corresponding to the commercial standard for LWRs were required. Thus, Japan Nuclear Energy Safety Organization (JNES) formulated a fire protection guidelines for nuclear fuel cycle facilities as a standard relevant to the fire protection of the nuclear fuel cycle facilities considering functions specific to the nuclear fuel cycle facilities. In formulating the guidelines, investigation has been conduced on the commercial guidelines for nuclear reactors in Japan and the standards relevant to the fire protection of nuclear facilities in USA and other countries as well as non-nuclear industrial fire protection standards. The guideline consists of two parts; Equipments and Management, as the commercial guidances of the nuclear reactor. In addition, the acquisition of fire evaluation data for a components (an electric cabinet, cable, oil etc.) targeted for spread of fire and the evaluation model of fire source were continued for the fire hazard analysis (FHA). (author)

  1. Fire and blast safety manual for fuel element manufacture

    Ensinger, U.; Koehler, B.; Mester, W.; Riotte, H.G.; Sehrbrock, H.W.

    1988-01-01

    The manual aims to enable people involved in the planning, operation, supervision, licensing or appraisal of fuel element factories to make a quick and accurate assessment of blast safety. In Part A, technical plant principles are shown, and a summary lists the flammable materials and ignition sources to be found in fuel element factories, together with theoretical details of what happens during a fire or a blast. Part B comprises a list of possible fires and explosions in fuel element factories and ways of preventing them. Typical fire and explosion scenarios are analysed more closely on the basis of experiments. Part B also contains a list and an assessment of actual fires and explosions which have occurred in fuel element factories. Part C contains safety measures to protect against fire and explosion, in-built fire safety, fire safety in plant design, explosion protection and measures to protect people from radiation and other hazards when fighting fires. A distinction is drawn between UO 2 , MOX and HTR fuel elements. (orig./DG) [de

  2. Releases of UF6 to the atmosphere after a potential fire in a cylinder storage yard

    Lombardi, D.A.; Williams, W.R.; Anderson, J.C.

    1997-01-01

    Uranium hexafluoride (UF 6 ), a toxic material, is stored in just over 6200 cylinders at the K-25 site in Oak Ridge, Tennessee. The safety analysis report (SAR) for cylinder yard storage operations at the plant required the development of accident scenarios for the potential release of UF 6 to the atmosphere. In accordance with DOE standards and guidance, the general approach taken in this SAR was to examine the functions and contents of the cylinder storage yards to determine whether safety-significant hazards were present for workers in the immediate vicinity, workers on-site, the general public off-site, or the environment. and to evaluate the significance of any hazards that were found. A detailed accident analysis was performed to determine a set of limiting accidents that have potential for off-site consequences. One of the limiting accidents identified in the SAR was the rupture of a cylinder engulfed in a fire

  3. The aspects of fire safety at landfills

    Aleshina Tat'yana Anatol'evna

    2014-01-01

    Full Text Available Starting with 2008 and till 2013 there have been alarm messages about fires occurring at landfill places in Russia. Landfill fires are especially dangerous as they emit dangerous fumes from the combustion of the wide range of materials within the landfill. Subsurface landfill fires, unlike typical fires, cannot be put out with water. The article includes the analysis of the sources and causes of conflagrations at landfills. There maintains the necessity to eliminate the reasons, which cause the fires. There are quantification indices of environmental, social and economic effects of fires at landfills all over Russia. Surface fires generally burn at relatively low temperatures and are characterized by the emission of dense white smoke and the products of incomplete combustion. The smoke includes irritating agents, such as organic acids and other compounds. Higher temperature fires can cause the breakdown of volatile compounds, which emit dense black smoke. Surface fires are classified as either accidental or deliberate. For the ecologic security there is a need in the execution of proper hygienic requirements to the content of the places as well as international recommendations. In addition to the burning and explosion hazards posed by landfill fires, smoke and other by-products of landfill fires also present a health risk to firefighters and others exposed to them. Smoke from landfill fires generally contains particulate matter (the products of incomplete combustion of the fuel source, which can aggravate pre-existing pulmonary conditions or cause respiratory distress and damage ecosystem. The monitoring of conducting preventive inflamings and transition to alternative, environment friendly methods of waste disposal is needed.

  4. Influence of safeguards and fire protection on criticality safety

    Six, D.E.

    1980-01-01

    There are several positive influences of safeguards and fire protection on criticality safety. Experts in each discipline must be aware of regulations and requirements of the others and work together to ensure a fault-tree design. EG and G Idaho, Inc., routinely uses an Occupancy-Use Readiness Manual to consider all aspects of criticality safety, fire protection, and safeguards. The use of the analytical tree is described

  5. Gypsum plasterboards enhanced with phase change materials: A fire safety assessment using experimental and computational techniques

    Kolaitis Dionysios I.

    2013-11-01

    Full Text Available Phase Change Materials (PCM can be used for thermal energy storage, aiming to enhance building energy efficiency. Recently, gypsum plasterboards with incorporated paraffin-based PCM blends have become commercially available. In the high temperature environment developed during a fire, the paraffins, which exhibit relatively low boiling points, may evaporate and, escaping through the gypsum plasterboard's porous structure, emerge to the fire region, where they may ignite, thus adversely affecting the fire resistance characteristics of the building. Aiming to assess the fire safety behaviour of such building materials, an extensive experimental and computational analysis is performed. The fire behaviour and the main thermo-physical physical properties of PCM-enhanced gypsum plasterboards are investigated, using a variety of standard tests and devices (Scanning Electron Microscopy, Thermo Gravimetric Analysis, Cone Calorimeter. The obtained results are used to develop a dedicated numerical model, which is implemented in a CFD code. CFD simulations are validated using measurements obtained in a cone calorimeter. In addition, the CFD code is used to simulate an ISO 9705 room exposed to fire conditions, demonstrating that PCM addition may indeed adversely affect the fire safety of a gypsum plasterboard clad building.

  6. Upgrading of fire safety in nuclear power plants. Proceedings of an International Symposium

    NONE

    1998-04-01

    The document includes 40 papers presented at the International Symposium on Upgrading of Fire Safety in Nuclear Power Plants held in Vienna between 18-21 November 1997. The symposium presentations were grouped in 6 sessions: Fire safety reviews (5 papers), Fire safety analysis - Methodology (6 papers), Fire safety analysis - Applications (3 papers), Panel 1 - Identification of deficiencies in fire safety in nuclear power plants - Operational experience and data (7 papers), Panel 2 - Experience based data in fire safety assessment - Fire safety regulations and licensing (7 papers), Upgrading programmes (10 papers), and a closing session (2 papers). A separate abstract was prepared for each paper Refs, figs, tabs

  7. Upgrading of fire safety in nuclear power plants. Proceedings of an International Symposium

    1998-04-01

    The document includes 40 papers presented at the International Symposium on Upgrading of Fire Safety in Nuclear Power Plants held in Vienna between 18-21 November 1997. The symposium presentations were grouped in 6 sessions: Fire safety reviews (5 papers), Fire safety analysis - Methodology (6 papers), Fire safety analysis - Applications (3 papers), Panel 1 - Identification of deficiencies in fire safety in nuclear power plants - Operational experience and data (7 papers), Panel 2 - Experience based data in fire safety assessment - Fire safety regulations and licensing (7 papers), Upgrading programmes (10 papers), and a closing session (2 papers). A separate abstract was prepared for each paper

  8. Instrumentation for mine safety: fire and smoke problems and solutions

    Stevens, R.B.

    1982-01-01

    Underground fires continue to be one of the most serious hazards to life and property in the mining industry. Although underground mines are analogous to high-rise buildings where persons are isolated from immediate escape or rescue, application of technology to locate and control fire hazards while still in their controllable state is slow to be implemented in underground mines. This paper describes several USBM (Bureau of Mines) safety programs which included in-mine testing with mine fire and smoke sensors, telemetry and instrumentation to develop recommendations for improving mine fire safety. It is hoped that the technology developed during these programs can be added to other programs to provide the mining industry with the necessary fire safety facts. By recognizing fire potentials and being provided with cost-effective, proven components that will perform reliably under the poor environmental conditions of mining, mine operators can provide protection for their working life and property equal to that which they provide for themselves and their families at home. The basis of this report is two USBM programs for fire protection in metal and nonmetal mines and one coal program. The data was collected beginning in May 1974 and continuing through the present with underground tests of a South African fire system installed at Magma Mine in Superior, Arizona, and a computer-assisted, experimental system at Peabody Coal Mine in Pawnee, Illinois

  9. Temperature calculation in fire safety engineering

    Wickström, Ulf

    2016-01-01

    This book provides a consistent scientific background to engineering calculation methods applicable to analyses of materials reaction-to-fire, as well as fire resistance of structures. Several new and unique formulas and diagrams which facilitate calculations are presented. It focuses on problems involving high temperature conditions and, in particular, defines boundary conditions in a suitable way for calculations. A large portion of the book is devoted to boundary conditions and measurements of thermal exposure by radiation and convection. The concepts and theories of adiabatic surface temperature and measurements of temperature with plate thermometers are thoroughly explained. Also presented is a renewed method for modeling compartment fires, with the resulting simple and accurate prediction tools for both pre- and post-flashover fires. The final chapters deal with temperature calculations in steel, concrete and timber structures exposed to standard time-temperature fire curves. Useful temperature calculat...

  10. Integrated approach to fire safety at the Krsko nuclear power plant - fire protection action plan

    Lambright, J.A.; Cerjak, J.; Spiler, J.; Ioannidi, J.

    1998-01-01

    Nuclear Power Plant Krsko (NPP Krsko) is a Westinghouse design, single-unit, 1882 Megawatt thermal (MWt), two-loop, pressurized water nuclear power plant. The fire protection program at NPP Krsko has been reviewed and reports issued recommending changes and modifications to the program, plant systems and structures. Three reports were issued, the NPP Krsko Fire Hazard Analysis (Safe Shout down Separation Analysis Report), the ICISA Analysis of Core Damage Frequency Due to Fire at the NPP Krsko and IPEEE (Individual Plant External Event Examination) related to fire risk. The Fire Hazard Analysis Report utilizes a compliance - based deterministic approach to identification of fire area hazards. This report focuses on strict compliance from the perspective of US Nuclear Regulatory Commission (USNRC), standards, guidelines and acceptance criteria and does not consider variations to comply with the intent of the regulations. The probabilistic analysis methide used in the ICISA and IPEEE report utilizes a risk based nad intent based approach in determining critical at-risk fire areas. NPP Krsko has already completed the following suggestions/recommendations from the above and OSART reports in order to comply with Appendix R: Installation of smoke detectors in the Control Room; Installation of Emergency Lighting in some plant areas and of Remote Shout down panels; Extension of Sound Power Communication System; Installation of Fire Annunciator Panel at the On-site Fire Brigade Station; Installation of Smoke Detection System in the (a) Main Control Room Panels, (b) Essential Service Water Building. (c) Component Cooling Building pump area, chiller area and HVAC area, (d) Auxiliary Building Safety pump rooms, (e) Fuel Handling room, (f) Intermediate Building AFFW area and compressor room, and (g) Tadwaste building; inclusion of Auxiliary operators in the Fire Brigade; training of Fire Brigade Members in Plant Operation (9 week course); Development of Fire Door Inspection and

  11. The Italian National Guidelines for the fire safety of facades

    Lamberto Mazziotti

    2013-11-01

    Full Text Available Traditionally, the facades' design buildings where once only focused on architectural or aesthetic purposes (in addition, of course, of whether protective issues. Nowadays, thanks to the technological development of the construction works and the use of new types of materials, the facades' design should also address fire safety related aspects. In Europe and especially in Italy – where the types of building façades are built with windows of small surface and natural stone coverings – the green building/sustainability movement has resulted in the development of new concepts in facade or curtain wall design that intended to enhance the energy efficiency of building façades. These new building surfaces are covered by extensive panelling fitted with insulating materials or by wide glass surfaces, capable of carry out the most diverse purposes including, just to name a few: energy reduction, climate comfort, recovery of electricity through photovoltaic panels that convert sunlight into electricity, large space for advertising purpose. One of the main fire safety goal for a building design is to restrict the vertical fire spread so that the smoke and flames are limited to the fire origin floor. The new building façade and curtain wall topologies could overwhelms concerns for fire safety, therefore the Italian National fire service has released a Fire Code Guideline in order to address the fire safety design for an high rise building façade. This paper aims to show the guideline contents and the related fire safety façades concerns.

  12. Thermal Radiation for Structural Fire Safety Design

    Hertz, Kristian Dahl

    2006-01-01

    The lecture notes give a short introduction of the theory of thermal radiation. The most elementary concepts and methods are presented in order to give a fundamental knowledge for calculation of the load bearing capacities of fire exposed building constructions....

  13. EFFICIENCY OF FIRE-FIGHTING PROTECTION OBJECTS IN PROVISION OF FIRE SAFETY AT INDUSTRIAL ENTERPRISES

    A. V. Zhovna

    2008-01-01

    Full Text Available The paper gives an analysis of economic results pertaining to organization of a system for fire-fighting protection of industrial enterprises in theRepublicofBelarus. Statistical data on operational conditions of technical means of fire-fighting protection, particularly, automatic systems for detection and extinguishing of fires, systems of internal fire-fighting water-supply.  Requirements and provisions  of normative and technical documents are thoroughly studied. Observance of these documents is to ensure the required level of  fire safety. On the basis of the obtained results concerning  economic analysis of efficiency optimization directions are defined for selection of technical means of fire-fighting protection at objects of industrial purpose.

  14. 20 CFR 654.417 - Fire, safety, and first aid.

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Fire, safety, and first aid. 654.417 Section..., safety, and first aid. (a) All buildings in which people sleep or eat shall be constructed and maintained...-type water extinguisher. (g) First aid facilities shall be provided and readily accessible for use at...

  15. Fire safety in nuclear power stations

    Kench, R.L.

    1988-01-01

    This is the first of a three-part report on the fire hazards in nuclear power stations and some of the precautions necessary. This part lists the United Kingdom reactors, outlines how they work, the fuels used, the use of moderators and coolants and the control systems. Although the risk of fire is no higher than in fossil-fuel stations the consequences can be more serious. The radioactive materials used mean that there is biological shielding round the core, limitations on waste emissions allowed and limited access to some zones. Reliable shut-down systems are needed. Care in the use of water to fight fires must be exercised -it can act as a moderator and cause an otherwise safe core to go critical. The Wigner effect in graphite moderated reactors is explained. Fires in graphite can be extinguished by carbon dioxide. Argon, chlorine and sodium silicate can also be effective. In sodium cooled reactors fires can be allowed to burn themselves out, or TEC and argon could be used to extinguish the flame. (UK)

  16. Fire and explosion safety in the petroleum sector

    NONE

    2006-07-01

    The conference has 13 presentations in topics on LNG projects nationally and internationally, simulations of gas dispersion due to LNG discharges, transports of pressurized natural gas, technological aspects of fire protection and combat equipment, safety aspects of offshore installations and transportation systems, offshore platform and transportation systems design and various examples of safety design and management. Some experiences within safety engineering in the petroleum exploitation are included.

  17. Thermal safety analysis of a dry storage cask for the Korean standard spent fuel - 16159

    Cha, Jeonghun; Kim, S.N.; Choi, K.W.

    2009-01-01

    A conceptual dry storage facility, which is based on a commercial dry storage facility, was designed for the Korea standard spent nuclear fuel (SNF) and preliminary thermal safety analysis was performed in this study. To perform the preliminary thermal analysis, a thermal analysis method was proposed. The thermal analysis method consists of 2 parts. By using the method, the surface temperature of the storage canister corresponding to the SNF clad temperature was calculated and the adequate air duct area was decided using the calculation result. The initial temperature of the facility was calculated and the fire condition and half air duct blockage were analyzed. (authors)

  18. Microgravity Flammability Experiments for Spacecraft Fire Safety

    Legros, Guillaume; Minster, Olivier; Tóth, Balazs

    2012-01-01

    As fire behaviour in manned spacecraft still remains poorly understood, an international topical team has been created to design a validation experiment that has an unprecedented large scale for a microgravity flammability experiment. While the validation experiment is being designed for a re-sup...

  19. Sodium fires and nuclear power station safety

    Ivanenko, V.N.; Zubin, A.; Drobyshev, A.V.

    1986-01-01

    The danger of sodium aerosol release at a design basis accident (DBA) of a sodium-cooled fast reactor that involves coolant leakage and burning, is being analyzed. It has been shown that radioactive and toxic releases at DBA do not exceed permissible values. Some means of sodium fire fighting are described. (author)

  20. Archer Fire and Safety - reducing risk in the offshore

    Todd, K

    2000-06-01

    Protecting the lives and safety of offshore oil and gas workers is the business of Newfoundland-based Archer Fire and Safety. Originally established as a supplier of industrial materials focusing on the oil and gas industry, the company narrowed its focus in 1996 to fire and safety protection, introduced more specialized fire and safety equipment, and began to explore service opportunities to the industry in addition to the usual consumables. After some anxious few years, the company now operates two SCBA service centres in Newfoundland, in addition to sales and servicing a wide range of fire and safety equipment such as gas, flame and heat detection.The company is constantly on the lookout for new opportunities and has developed a computer-based pricing system which enables them to provide quick response to pricing inquiries, a big advantage in an industry with relatively unsophisticated business practices. The company's emphasis on research and quick response capability enabled the company to anticipate future requirements and to land major contracts first at Bull Arm, and later on the Terra Nova Project. Its reputation for best-in-class products, high quality service and a business-like approach helped to attract other clients such as Terra Nova Alliance, Canship and Schlumberger, and offshore drilling companies like Glomar International and TransOcean Sedco-Forex, with further opportunities in the offing with upcoming projects such as the White Rose and Hebron.Today about 60 per cent of the business is offshore related.

  1. Archer Fire and Safety - reducing risk in the offshore

    Todd, K.

    2000-06-01

    Protecting the lives and safety of offshore oil and gas workers is the business of Newfoundland-based Archer Fire and Safety. Originally established as a supplier of industrial materials focusing on the oil and gas industry, the company narrowed its focus in 1996 to fire and safety protection, introduced more specialized fire and safety equipment, and began to explore service opportunities to the industry in addition to the usual consumables. After some anxious few years, the company now operates two SCBA service centres in Newfoundland, in addition to sales and servicing a wide range of fire and safety equipment such as gas, flame and heat detection.The company is constantly on the lookout for new opportunities and has developed a computer-based pricing system which enables them to provide quick response to pricing inquiries, a big advantage in an industry with relatively unsophisticated business practices. The company's emphasis on research and quick response capability enabled the company to anticipate future requirements and to land major contracts first at Bull Arm, and later on the Terra Nova Project. Its reputation for best-in-class products, high quality service and a business-like approach helped to attract other clients such as Terra Nova Alliance, Canship and Schlumberger, and offshore drilling companies like Glomar International and TransOcean Sedco-Forex, with further opportunities in the offing with upcoming projects such as the White Rose and Hebron.Today about 60 per cent of the business is offshore related.

  2. Operating room fire prevention: creating an electrosurgical unit fire safety device.

    Culp, William C; Kimbrough, Bradly A; Luna, Sarah; Maguddayao, Aris J

    2014-08-01

    To reduce the incidence of surgical fires. Operating room fires represent a potentially life-threatening hazard and are triggered by the electrosurgical unit (ESU) pencil. Carbon dioxide is a fire suppressant and is a routinely used medical gas. We hypothesize that a shroud of protective carbon dioxide covering the tip of the ESU pencil displaces oxygen, thereby preventing fire ignition. Using 3-dimensional modeling techniques, a polymer sleeve was created and attached to an ESU pencil. This sleeve was connected to a carbon dioxide source and directed the gas through multiple precisely angled ports, generating a cone of fire-suppressive carbon dioxide surrounding the active pencil tip. This device was evaluated in a flammability test chamber containing 21%, 50%, and 100% oxygen with sustained ESU activation. The sleeve was tested with and without carbon dioxide (control) until a fuel was ignited or 30 seconds elapsed. Time to ignition was measured by high-speed videography. Fires were ignited with each control trial (15/15 trials). The control group median ± SD ignition time in 21% oxygen was 3.0 ± 2.4 seconds, in 50% oxygen was 0.1 ± 1.8 seconds, and in 100% oxygen was 0.03 ± 0.1 seconds. No fire was observed when the fire safety device was used in all concentrations of oxygen (0/15 trials; P fire ignition was 76% to 100%. A sleeve creating a cone of protective carbon dioxide gas enshrouding the sparks from an ESU pencil effectively prevents fire in a high-flammability model. Clinical application of this device may reduce the incidence of operating room fires.

  3. Evacuation routes performances and fire safety of buildings

    Laban Mirjana Đ.

    2015-01-01

    Full Text Available Residential buildings, public and business facilities with large number of occupants are particularly exposed to the risk of event with catastrophic consequences, especially in case of fire. Evacuation routes must be separated fire compartments with surfaces made of non-combustible materials. Safe evacuation of building occupants in case of fire is a crucial requirement for the preservation of human life in building. In our engineering practice, calculation model is usually applied in order to determine the time required for evacuation (SRPS TP 21. However, evacuation simulation models are more present in research papers, contributing to better assessment of flow of evacuation in the real time. These models could provide an efficient way of testing the safety of a building in the face of fire and indicate critical points at the evacuation paths. Computer models enable the development and analysis of multiple various scenarios during a fire event, contributing to defining the measures for improving the safety of the building in case of fire. This paper analyses the fulfilment of technical requirements for the safe evacuation and proposes improvement measures based on a comparative analysis of the time required for occupants' evacuation from the building (Department of Civil Engineering and Geodesy in Novi Sad, obtained by calculation model and by using evacuation simulation software.

  4. Upgrading of fire safety in Indian nuclear power plants

    Agarwal, N.K.

    1998-01-01

    Indian nuclear power programme started with the installation of 2 nos. of Boiling Water Reactor (BWR) at Tarapur (TAPS I and II) of 210 MWe each commissioned in the year 1996. The Pressurized Heavy Water Reactor (PHWR) programme in the country started with the installation of 2x220 MWe stations at Rawatbhatta near Kota (RAPS I and II) in the State of Rajasthan in the sixties. At the present moment, the country has 10 stations in operation. Construction is going on for 4 more units of 220 MWe where as work on two more 500 MWe units is going to start soon. Fire safety systems for the earlier units were engineered as per the state-of-art knowledge available then. The need for review of fire protection systems in the Indian nuclear power plants has also been felt since long almost after Brown's Ferry fire in 1975 itself. Task forces consisting of fire experts, systems design engineers, O and M personnel as well as the Fire Protection engineers at the plant were constituted for each plant to review the existing fire safety provisions in details and highlight the upgradation needed for meeting the latest requirements as per the national as well as international practices. The recommendations made by three such task forces for the three plants are proposed to be reviewed in this paper. The paper also highlights the recommendations to be implemented immediately as well as on long-term basis over a period of time

  5. Development of IFC based fire safety assesment tools

    Taciuc, Anca; Karlshøj, Jan; Dederichs, Anne

    2016-01-01

    Due to the impact that the fire safety design has on the building's layout and on other complementary systems, as installations, it is important during the conceptual design stage to evaluate continuously the safety level in the building. In case that the task is carried out too late, additional...... changes need to be implemented, involving supplementary work and costs with negative impact on the client. The aim of this project is to create a set of automatic compliance checking rules for prescriptive design and to develop a web application tool for performance based design that retrieves data from...... Building Information Models (BIM) to evacuate the safety level in the building during the conceptual design stage. The findings show that the developed tools can be useful in AEC industry. Integrating BIM from conceptual design stage for analyzing the fire safety level can ensure precision in further...

  6. Parametric study for the fire safety design of steel structures

    Aiuti, Riccardo; Giuliani, Luisa

    2013-01-01

    the considered time of fire exposure. A deeper knowledge on the failure mode of steel structure is however important in order to ensure the safety of the people and properties outside the building. Aim of this paper is to analyze the behaviour of single elements, sub-assemblies and frames exposed to fire...... or hindered thermal expansion induced on the element by the rest of the structure. Nevertheless, restrained thermal expansion is known to significantly affect the behaviour of steel structures in fire, and the compliance with a prescribed resistance class doesn’t ensure the integrity of the building after...... and find out the basic collapse mechanisms of structural elements in fire conditions, considering the rest of the construction with appropriate constraints. The analysis is carried out taking into account material and geometrical nonlinearities as well as the degradation of steel properties at high...

  7. Evaluation of fire safety measures at local universities in Kenya with ...

    This study establishes fire safety measures in place in local universities in Kenya, and ... fire suppression systems, fire detection and alarm systems and fire Hydrants. ... response backed by university management endorsement and support. The Directorate of occupational safety and health services should also make the ...

  8. Safety demonstration test on solvent fire in fuel reprocessing plant

    Nishio, Gunji; Hashimoto, Kazuichiro

    1989-03-01

    This report summarizes a fundamental of results obtained in the Reprocessing Plant Safety Demonstration Test Program which was performed under the contract between the Science and Technology Agency of Japan and the Japan Atomic Energy Research Institute. In this test program, a solvent fire was hypothesized, and such data were obtained as fire behavior, smoke behavior and integrity of exhaust filters in the ventilation system. Through the test results, it was confirmed that under the fire condition in hypothetical accident, the integrity of the cell and the cell ventilation system were maintained, and the safety function of the exhaust filters was maintained against the smoke loading. Analytical results by EVENT code agreed well with the present test data on the thermofluid flow in a cell ventilation system. (author)

  9. Organization and conduct of IAEA fire safety reviews at nuclear power plants

    1998-01-01

    The importance of fire safety in the safe and productive operation of nuclear power plants is recognized worldwide. Lessons learned from experience in nuclear power plants indicate that fire poses a real threat to nuclear safety and that its significance extends far beyond the scope of a conventional fire hazard. With a growing understanding of the close correlation between the fire hazard in nuclear power plants and nuclear safety, backfitting for fire safety has become necessary for a number of operating plants. However, it has been recognized that the expertise necessary for a systematic independent assessment of fire safety of a NPP may not always be available to a number of Member States. In order to assist in enhancing fire safety, the IAEA has already started to offer various services to Member States in the area of fire safety. At the request of a Member State, the IAEA may provide a team of experts to conduct fire safety reviews of varying scope to evaluate the adequacy of fire safety at a specific nuclear power plant during various phases such as construction, operation and decommissioning. The IAEA nuclear safety publications related to fire protection and fire safety form a common basis for these reviews. This report provides guidance for the experts involved in the organization and conduct of fire safety review services to ensure consistency and comprehensiveness of the reviews

  10. Fire Hazards Analysis for the Inactive Equipment Storage Sprung Structure

    MYOTT, C.F.

    2000-01-01

    The purpose of the analysis is to comprehensively assess the risk from fire within individual fire areas in relation to proposed fire protection so as to ascertain whether the fire protection objective of DOE Order 5480.1A are met. The order acknowledges a graded approach commensurate with the hazards involved

  11. Safety assessment of indoor live fire range, May 1989

    NONE

    1989-05-01

    The following Safety Assessment (SA) pertains to the indoor live fire range (LFR) at EG&G Mound Applied Technology plant. The purpose of the indoor LFR is to conduct training with live ammunition for all designated personnel. The SA examines the risks that are attendant to the operation of an indoor LFR for this purpose.

  12. Safety assessment of radioactive wastes storage 'Mironova Gora'

    Serbryakov, B.; Karamushka, V.; Ostroborodov, V.

    2000-01-01

    A project of transforming the radioactive wastes storage 'Mironova Gora' is under development. A safety assessment of this storage facility was performed to gain assurance on the design decision. The assessment, which was based on the safety assessment methods developed for radioactive wastes repositories, is presented in this paper. (author)

  13. Fire impact on carbon storage in light conifer forests of the Lower Angara region, Siberia

    Ivanova, G A; Kukavskaya, E A; Conard, S G; McRae, D J

    2011-01-01

    This study focused on structural analysis of ground carbon storage following fires in light conifer stands of the Lower Angara region (Siberia, Russia). Experimental fires of varying frontal intensity were conducted at Scots pine and mixed larch forests of southern taiga. Considerable amounts of surface and ground forest fuels (21–38 tC ha −1 ) enhanced low- to high-intensity fires. Post-fire carbon storage decreased by 16–49% depending on fire intensity and rate of spread, with depth of burn being 0.9–6.6 cm. Carbon emissions varied from 4.48 to 15.89 t ha −1 depending on fire intensity and forest type. Depth of burn and carbon emissions for four major site types were correlated with a weather-based fire hazard index.

  14. Storage of Spent Nuclear Fuel. Specific Safety Guide

    2012-01-01

    This Safety Guide provides recommendations and guidance on the storage of spent nuclear fuel. It covers all types of storage facilities and all types of spent fuel from nuclear power plants and research reactors. It takes into consideration the longer storage periods that have become necessary owing to delays in the development of disposal facilities and the decrease in reprocessing activities. It also considers developments associated with nuclear fuel, such as higher enrichment, mixed oxide fuels and higher burnup. The Safety Guide is not intended to cover the storage of spent fuel if this is part of the operation of a nuclear power plant or spent fuel reprocessing facility. Guidance is provided on all stages for spent fuel storage facilities, from planning through siting and design to operation and decommissioning, and in particular retrieval of spent fuel. Contents: 1. Introduction; 2. Protection of human health and the environment; 3. Roles and responsibilities; 4. Management system; 5. Safety case and safety assessment; 6. General safety considerations for storage of spent fuel. Appendix I: Specific safety considerations for wet or dry storage of spent fuel; Appendix II: Conditions for specific types of fuel and additional considerations; Annex: I: Short term and long term storage; Annex II: Operational and safety considerations for wet and dry spent fuel storage facilities; Annex III: Examples of sections of operating procedures for a spent fuel storage facility; Annex IV: Site conditions, processes and events for consideration in a safety assessment (external human induced phenomena); Annex V: Site conditions, processes and events for consideration in a safety assessment (external natural phenomena); Annex VI: Site conditions, processes and events for consideration in a safety assessment (external human induced phenomena); Annex VII: Postulated initiating events for consideration in a safety assessment (internal phenomena).

  15. Fire safety case study of a railway tunnel: Smoke evacuation

    van Maele Karim

    2007-01-01

    Full Text Available When a fire occurs in a tunnel, it is of great importance to assure the safety of the occupants of the tunnel. This is achieved by creating smoke-free spaces in the tunnel through control of the smoke gases. In this paper, results are presented of a study concerning the fire safety in a real scale railway tunnel test case. Numerical simulations are performed in order to examine the possibility of natural ventilation of smoke in inclined tunnels. Several aspects are taken into account: the length of the simulated tunnel section, the slope of the tunnel and the possible effects of external wind at one portal of the tunnel. The Fire Dynamics Simulator of the National Institute of Standards and Technology, USA, is applied to perform the simulations. The simulations show that for the local behavior of the smoke during the early stages of the fire, the slope of the tunnel is of little importance. Secondly, the results show that external wind and/or pressure conditions have a large effect on the smoke gases inside the tunnel. Finally, some idea for the value of the critical ventilation velocity is given. The study also shows that computational fluid dynamics calculations are a valuable tool for large scale, real life complex fire cases. .

  16. Safety report for Central Interim Storage facility for radioactive waste from small producers

    Zeleznik, N.; Mele, I.

    2004-01-01

    In 1999 the Agency for Radwaste Management took over the management of the Central Interim Storage (CIS) in Brinje, intended only for radioactive waste from industrial, medical and research applications. With the transfer of the responsibilities for the storage operation, ARAO, the new operator of the facility, received also the request from the Slovenian Nuclear Safety Administration for refurbishment and reconstruction of the storage and for preparation of the safety report for the storage with the operational conditions and limitations. In order to fulfill these requirements ARAO first thoroughly reviewed the existing documentation on the facility, the facility itself and the stored inventory. Based on the findings of this review ARAO prepared several basic documents for improvement of the current conditions in the storage facility. In October 2000 the Plan for refurbishment and modernization of the CIS was prepared, providing an integral approach towards remediation and refurbishment of the facility, optimization of the inventory arrangement and modernization of the storage and storing utilization. In October 2001 project documentation for renewal of electric installations, water supply and sewage system, ventilation system, the improvements of the fire protection and remediation of minor defects discovered in building were completed according to the Act on Construction. In July 2003 the safety report was prepared, based on the facility status after the completion of the reconstruction works. It takes into account all improvements and changes introduced by the refurbishment and reconstruction of the facility according to project documentation. Besides the basic characteristics of the location and its surrounding, it also gives the technical description of the facility together with proposed solutions for the renewal of electric installations, renovation of water supply and sewage system, refurbishment of the ventilation system, the improvement of fire

  17. 76 FR 70885 - Updating Fire Safety Standards

    2011-11-16

    ... effect on the economy of $100 million or more or adversely affect in a material way the economy, a sector of the economy, productivity, competition, jobs, the environment, public health or safety, or State...; 64.018, Sharing Specialized Medical Resources; 64.019, Veterans Rehabilitation Alcohol and Drug...

  18. 76 FR 10246 - Updating Fire Safety Standards

    2011-02-24

    ... public noted the importance of requiring facilities to meet up-to-date safety standards. The third... Affairs (VA) regulations concerning community residential care facilities, contract facilities for certain outpatient and residential services, and State home facilities. The final rule will clarify current...

  19. Methods for the sodium cooled fast reactor fire safety provisions

    Gryaznov, B.V.; Dergachev, N.P.

    1983-01-01

    Problems of fire safety provision on NPPs with sodium cooled fast reactor are under discussion. Methods of sodium leak localization, measures eliminating sodium flaring up during leaks and main means of sodium fire extinguishing are considered. An extinguishing of sodium flaring up is performed by means of sodium temperatUre decrease and by limitation of hydrogen access to the flaring up surface. A conclusion is made that the most effective methods of extinguishing are the following: self-extinguishing (due to hydrogen burning out in a limiting volume); extinguishing by a gas mixture of nitrogen and carbonic acid (initial filling and blowing of rooms during sodium flaring up); extinguishing by special powders

  20. Safety analysis report for the Waste Storage Facility. Revision 2

    Bengston, S.J.

    1994-05-01

    This safety analysis report outlines the safety concerns associated with the Waste Storage Facility located in the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory. The three main objectives of the report are: define and document a safety basis for the Waste Storage Facility activities; demonstrate how the activities will be carried out to adequately protect the workers, public, and environment; and provide a basis for review and acceptance of the identified risk that the managers, operators, and owners will assume.

  1. The practical implementation of integrated safety management for nuclear safety analysis and fire hazards analysis documentation

    COLLOPY, M.T.

    1999-01-01

    In 1995 Mr. Joseph DiNunno of the Defense Nuclear Facilities Safety Board issued an approach to describe the concept of an integrated safety management program which incorporates hazard and safety analysis to address a multitude of hazards affecting the public, worker, property, and the environment. Since then the U S . Department of Energy (DOE) has adopted a policy to systematically integrate safety into management and work practices at all levels so that missions can be completed while protecting the public, worker, and the environment. While the DOE and its contractors possessed a variety of processes for analyzing fire hazards at a facility, activity, and job; the outcome and assumptions of these processes have not always been consistent for similar types of hazards within the safety analysis and the fire hazard analysis. Although the safety analysis and the fire hazard analysis are driven by different DOE Orders and requirements, these analyses should not be entirely independent and their preparation should be integrated to ensure consistency of assumptions, consequences, design considerations, and other controls. Under the DOE policy to implement an integrated safety management system, identification of hazards must be evaluated and agreed upon to ensure that the public. the workers. and the environment are protected from adverse consequences. The DOE program and contractor management need a uniform, up-to-date reference with which to plan. budget, and manage nuclear programs. It is crucial that DOE understand the hazards and risks necessarily to authorize the work needed to be performed. If integrated safety management is not incorporated into the preparation of the safety analysis and the fire hazard analysis, inconsistencies between assumptions, consequences, design considerations, and controls may occur that affect safety. Furthermore, confusion created by inconsistencies may occur in the DOE process to grant authorization of the work. In accordance with

  2. Ensuring safety in monitored retrievable storage

    Guenther, R.J.; Gilbert, E.R.; Slate, S.C.; Devine, J.R.; Kreid, D.K.; Partain, W.L.

    1984-01-01

    The behaviour of spent fuel in dry storage will be one of the principal considerations in the design of monitored retrievable storage (MRS) facilities. Reliable predictive tools for extrapolating fuel performance during long storage periods can provide guidance and criteria for the design and operation of MRS facilities. This article reviews the results of recent efforts to predict the degradation of spent fuel in MRS and summarises the expected performance of other waste forms during storage. (author)

  3. Fire safety in dental clinics: Basics for dentists and dental students

    Kalyana Chakravarthy Pentapati

    2015-01-01

    Full Text Available Fire safety is essential component and requirement in health care sector. It includes components like emergency exits, manual call outs, different types of fire extinguishers, safe assembly area, fire hydrant system with water sprinkler systems etc. We attempt to provide some basics about fire and fire safety that are prerequisite for safe working environment in dental clinics along with some recommendations that can be incorporated in the curriculum.

  4. Criticality safety for TMI-2 canister storage at INEL

    Jones, R.R.; Briggs, J.B.; Ayers, A.L. Jr.

    1986-01-01

    Canisters containing Three Mile Island Unit 2 (TMI-2) core debris will be researched, stored, and prepared for final disposition at the Idaho National Engineering Laboratory (INEL). The canisters will be placed into storage modules and assembled into a storage rack, which will be located in the Test Area North (TAN) storage pool. Criticality safety calculations were made (a) to ensure that the storage rack is safe for both normal and accident conditions and (b) to determine the effects of degradation of construction materials (Boraflex and polyethylene) on criticality safety

  5. EFFECTS OF FIRE FUMES ON ALMOND SAFETY AND QUALITY

    Amanda Ramírez-Gandolfo

    2011-08-01

    Full Text Available A fire originated and burnt two cold chambers; the present study focused on almonds stored in adjacent chambers (4, 5, 6 and 13 and evaluated both their food safety and quality. Testing for polycyclic aromatic hydrocarbons, polychlorinated dibenzo-p-dioxins and dibenzofurans was carried out in affected facilities, packaging and almonds. Experimental results proved that fire fumes did not reach chambers 4-6, but traces were found in bin packaging of chamber 13; thus, packaging from this chamber were changed. Concentrations of benzo(apyrene were low enough to prove that fire fumes did not get in contact with the stored almonds. Later, only volatile compounds typical of nuts were identified in both raw and toasted almonds. Finally, a trained panel concluded that no sensory signal of fumes reaching almonds was found. This manuscript could be taken as a model protocol to establish whether fire fumes have reached and affected the safety and/or quality of foods. This information will be especially useful for insurance companies.

  6. Fire Safety Aspects of Polymeric Materials. Volume 7. Buildings

    1979-01-01

    Custodial Buildings 136 4.5.5 Retail Stores, Malls, etc. 138 l’ 4.5.6 Restaurants and Nightclubs 4.5.7 Public Assembly Occupancies - Auditoria , Theaters... auditoria , theaters, exhibition halls, arenas, transportation terminals; educational buildings and indus- trial buildings. Many of the fire safety...usage are developed. 4.5.7 Public Assembly Occupancies - Auditoria , Theaters, Exhibition Halls, Arenas, Transportation Terminals, Etc. The factors

  7. Evaluation Of Fire Safety And Protection At PUSPATI TRIGA Reactor (RTP)

    Ahmad Nabil Ab Rahim; Alfred Sanggau Ligam; Nurhayati Ramli; Mohd Fazli Zakaria; Naim Syauqi Hamzah; Phongsakorn Prak; Mohammad Suhaimi Kassim; Zarina Masood

    2014-01-01

    Fire hazard is one of many risks that can affect the safety operation of PUSPATI TRIGA Reactor. Reactor building in Malaysian Nuclear Agency was built in 1980s and the fire system has been introduced since then. The evaluation of the fire safety system at this time is important to ensure the efficiency of fire prevention, fighting and mitigation task that probably occurs. This evaluation involves with the fire fighting system and equipment, integrity of the system from the perspective of management and equipment, fire fighting procedure and fire fighting response team. (author)

  8. A probabilistic method for optimization of fire safety in nuclear power plants

    Hosser, D.; Sprey, W.

    1986-01-01

    As part of a comprehensive fire safety study for German Nuclear Power Plants a probabilistic method for the analysis and optimization of fire safety has been developed. It follows the general line of the American fire hazard analysis, with more or less important modifications in detail. At first, fire event trees in selected critical plant areas are established taking into account active and passive fire protection measures and safety systems endangered by the fire. Failure models for fire protection measures and safety systems are formulated depending on common parameters like time after ignition and fire effects. These dependences are properly taken into account in the analysis of the fire event trees with the help of first-order system reliability theory. In addition to frequencies of fire-induced safety system failures relative weights of event paths, fire protection measures within these paths and parameters of the failure models are calculated as functions of time. Based on these information optimization of fire safety is achieved by modifying primarily event paths, fire protection measures and parameters with the greatest relative weights. This procedure is illustrated using as an example a German 1300 MW PWR reference plant. It is shown that the recommended modifications also reduce the risk to plant personnel and fire damage

  9. Fires at storage sites of organic materials, waste fuels and recyclables.

    Ibrahim, Muhammad Asim; Alriksson, Stina; Kaczala, Fabio; Hogland, William

    2013-09-01

    During the last decade, the European Union has enforced the diversion of organic wastes and recyclables to waste management companies operating incineration plants, composting plants and recycling units instead of landfills. The temporary storage sites have been established as a buffer against fluctuations in energy demand throughout the year. Materials also need to be stored at temporary storage sites before recovery and recycling. However, regulations governing waste fuel storage and handling have not yet been developed, and, as a result, companies have engaged in risky practices that have resulted in a high number of fire incidents. In this study, a questionnaire survey was distributed to 249 of the 400 members of Avfall Sverige (Swedish Waste Management Association), which represents the waste management of 95% of the Swedish population. Information regarding 122 storage facilities owned by 69 companies was obtained; these facilities were responsible for the storage of 47% of the total treated waste (incineration + digestion + composting) in 2010 in Sweden. To identify factors related to fire frequency, the questionnaire covered the amounts of material handled and burnt per year, financial losses due to fires, storage duration, storage method and types of waste. The results show that 217 fire incidents corresponded to 170 kilotonnes of material burnt and cumulative losses of 49 million SEK (€4.3 million). Fire frequency and amount of material burnt per fire was found to be dependent upon type of management group (waste operator). Moreover, a correlation was found between fire frequency and material recycled during past years. Further investigations of financial aspects and externalities of fire incidents are recommended.

  10. Safety Aspects of Long Term Spent Fuel Dry Storage

    Botsch, Wolfgang; Smalian, S.; Hinterding, P.; Drotleff, H.; Voelzke, H.; Wolff, D.; Kasparek, E.

    2014-01-01

    As a consequence of the lack of a final repository for spent nuclear fuel (SF) and high level waste (HLW), long term interim storage of SF and HLW will be necessary. As with the storage of all radioactive materials, the long term storage of SF and HLW must conform to safety requirements. Safety aspects such as safe enclosure of radioactive materials, safe removal of decay heat, sub-criticality and avoidance of unnecessary radiation exposure must be achieved throughout the complete storage period. The implementation of these safety requirements can be achieved by dry storage of SF and HLW in casks as well as in other systems such as dry vault storage systems or spent fuel pools, where the latter is neither a dry nor a passive system. After the events of Fukushima, the advantages of passively and inherently safe dry storage systems have become more obvious. In Germany, dry storage of SF in casks fulfils both transport and storage requirements. Mostly, storage facilities are designed as concrete buildings above the ground; one storage facility has also been built as a rock tunnel. In all these facilities the safe enclosure of radioactive materials in dry storage casks is achieved by a double-lid sealing system with surveillance of the sealing system. The safe removal of decay heat is ensured by the design of the storage containers and the storage facility, which also secures to reduce the radiation exposure to acceptable levels. TUV and BAM, who work as independent experts for the competent authorities, inform about spent fuel management and issues concerning dry storage of spent nuclear fuel, based on their long experience in these fields. All relevant safety issues such as safe enclosure, shielding, removal of decay heat and sub-criticality are checked and validated with state-of-the-art methods and computer codes before the license approval. In our presentation we discuss which of these aspects need to be examined closer for a long term interim storage. It is shown

  11. IRSN global process for leading a comprehensive fire safety analysis for nuclear installations

    Ormieres, Yannick; Lacoue, Jocelyne

    2013-01-01

    A fire safety analysis (FSA) is requested to justify the adequacy of fire protection measures set by the operator. A recent document written by IRSN outlines a global process for such a comprehensive fire safety analysis. Thanks to the French nuclear fire safety regulation evolutions, from prescriptive requirements to objective requirements, the proposed fire safety justification process focuses on compliance with performance criteria for fire protection measures. These performance criteria are related to the vulnerability of targets to effects of fire, and not only based upon radiological consequences out side the installation caused by a fire. In his FSA, the operator has to define the safety functions that should continue to ensure its mission even in the case of fire in order to be in compliance with nuclear safety objectives. Then, in order to maintain these safety functions, the operator has to justify the adequacy of fire protection measures, defined according to defence in depth principles. To reach the objective, the analysis process is based on the identification of targets to be protected in order to maintain safety functions, taken into account facility characteristics. These targets include structures, systems, components and personal important to safety. Facility characteristics include, for all operating conditions, potential ignition sources and fire protections systems. One of the key points of the fire analysis is the assessment of possible fire scenarios in the facility. Given the large number of possible fire scenarios, it is then necessary to evaluate 'reference fires' which are the worst case scenarios of all possible fire scenarios and which are used by the operator for the design of fire protection measures. (authors)

  12. 78 FR 17140 - Upholstered Furniture Fire Safety Technology; Meeting and Request for Comments

    2013-03-20

    ... retardant (FR) chemicals, specialty fibers/fabrics without FR chemicals, inherently fire resistant materials... Furniture Fire Safety Technology; Meeting and Request for Comments AGENCY: Consumer Product Safety... Commission (CPSC, Commission, or we) is announcing its intent to hold a meeting on upholstered furniture fire...

  13. Engineering and safety features of modular vault dry storage

    Deacon, D.; Wheeler, D.J.

    1984-01-01

    This paper discusses the need for interim dry storage and reviews detailed features of the Modular Vault Dry storage concept. The concept meets three basic utility requirements. Firstly, the technology and safety features have been demonstrated on existing plant; secondly, it can be built and licensed in an acceptably short timescale; and thirdly, economic analysis shows that a modular vault dry store is often the cheapest option for interim storage

  14. Use of operational experience in fire safety assessment of nuclear power plants

    2000-01-01

    Fire hazard has been identified as a major contributor to a plant's operational risk and the international nuclear power industry has been studying and developing tools for defending against this hazard. Considerable progress in design and regulatory requirements for fire safety, in fire protection technology and in related analytical techniques has been made in the past two decades. Substantial efforts have been undertaken worldwide to implement these advances in the interest of improving fire safety both at new and existing nuclear power plants. To assist in these efforts, the IAEA initiated a programme on fire safety that was intended to provide assistance to Member States in improving fire safety in nuclear power plants. In order to achieve this general objective, the IAEA programme aimed at the development of guidelines and good practices, the promotion of advanced fire safety assessment techniques, the exchange of state of the art information between practitioners and the provision of engineering safety advisory services and training in the implementation of internationally accepted practices. During the period 1993-1994, the IAEA activities related to fire safety concentrated on the development of guidelines and good practice documents related to fire safety and fire protection of operating plants. One of the first tasks was the development of a Safety Guide that formulates specific requirements with regard to the fire safety of operating nuclear power plants. Several documents, which provide advice on fire safety inspection, were developed to assist in its implementation. In the period 1995-1996, the programme focused on the preparation of guidelines for the systematic analysis of fire safety at nuclear power plants (NPPs). The IAEA programme on fire safety for 1997-1998 includes tasks aimed at promoting systematic assessment of fire safety related occurrences and dissemination of essential insights from this assessment. One of the topics addressed is the

  15. Fire safety of LPG in marine transportation. Final report

    Martinsen, W.E.; Johnson, D.W.; Welker, J.R.

    1980-06-01

    This report contains an analytical examination of cargo spill and fire hazard potential associated with the marine handling of liquefied petroleum gas (LPG) as cargo. Principal emphasis was on cargo transfer operations for ships unloading at receiving terminals, and barges loading or unloading at a terminal. Major safety systems, including emergency shutdown systems, hazard detection systems, and fire extinguishment and control systems were included in the analysis. Spill probabilities were obtained from fault tree analyses utilizing composite LPG tank ship and barge designs. Failure rates for hardware in the analyses were generally taken from historical data on similar generic classes of hardware, there being very little historical data on the specific items involved. Potential consequences of cargo spills of various sizes are discussed and compared to actual LPG vapor cloud incidents. The usefulness of hazard mitigation systems (particularly dry chemical fire extinguishers and water spray systems) in controlling the hazards posed by LPG spills and spill fires is also discussed. The analysis estimates the probability of fatality for a terminal operator is about 10/sup -6/ to 10/sup -5/ per cargo transfer operation. The probability of fatality for the general public is substantially less.

  16. Spacecraft Fire Safety 1956 to 1999: An Annotated Bibliography

    Friedman, Robert; Ruff, Gary A.

    2013-01-01

    Knowledge of fire safety in spacecraft has resulted from over 50 years of investigation and experience in space flight. Current practices and procedures for the operation of the Space Transportation System (STS) shuttle and the International Space Station (ISS) have been developed from this expertise, much of which has been documented in various reports. Extending manned space exploration from low Earth orbit to lunar or Martian habitats and beyond will require continued research in microgravity combustion and fire protection in low gravity. This descriptive bibliography has been produced to document and summarize significant work in the area of spacecraft fire safety that was published between 1956 and July 1999. Although some important work published in the late 1990s may be missing, these citations as well as work since 2000 can generally be found in Web-based resources that are easily accessed and searched. In addition to the citation, each reference includes a short description of the contents and conclusions of the article. The bibliography contains over 800 citations that are cross-referenced both by topic and the authors and editors. There is a DVD that accompanies this bibliography (available by request from the Center for Aerospace Information) containing the full-text articles of selected citations as well as an electronic version of this report that has these citations as active links to their corresponding full-text article.

  17. Safety analysis of the existing 850 Firing Facility

    Odell, B.N.

    1986-01-01

    A safety analysis was performed to determine if normal operations and/or potential accidents at the 850 Firing Facility at Site 300 could present undue hazards to the general public, personnel at Site 300, or have an adverse effect on the environment. The normal operations and credible accidents that might have an effect on these facilities or have off-site consequences were considered. It was determined by this analysis that all but one of the hazards were either low or of the type or magnitude routinely encountered and/or accepted by the public. The exception was explosives, which was classified as a moderate hazard per the requirements given in DOE Order 5481.1A. This safety analysis concluded that the operation at this facility will present no undue risk to the health and safety of LLNL employees or the public

  18. Safety analysis of the existing 851 Firing Facility

    Odell, B.N.

    1986-01-01

    A safety analysis was performed to determine if normal operations and/or potential accidents at the 851 Firing Facility at Site 300 could present undue hazards to the general public, personnel at Site 300, or have an adverse effect on the environment. The normal operations and credible accidents that might have an effect on these facilities or have off-site consequences were considered. It was determined by this analysis that all but two of the hazards were either low or of the type or magnitude routinely encountered and/or accepted by the public. The exceptions were the linear accelerator and explosives, which were classified as moderate hazards per the requirements given in DOE Order 5481.1A. This safety analysis concluded that the operation at this facility will present no undue risk to the health and safety of LLNL employees or the public

  19. Frequently Asked Questions in Fire Probabilistic Safety Assessment

    Kang, Dae Il; Kim, Kil Yoo; Park, Gee Yong

    2010-05-01

    The FAQs(Frequently Asked Questions) in the Fire Probabilistic Safety Assessment(FPSA) are the issues occurred during performing the engineering evaluation based on NFPA-805. In this report, the background and resolutions are reviewed and described for 17 FAQs related to FPSA among 57 FAQs. The current FAQs related to FPSA are the issues concerning to NUREG/CR-6850, and are almost resolved but for the some FAQ, the current resolutions would be changed depending on the results of the future or on-going research. Among FAQs related to FPSA, best estimate approaches are suggested concerning to the conservative method of NUREG/CR-6850. If these best estimate solutions are used in the FPSA of nuclear power plants, realistic evaluation results of fire risk would be obtained

  20. [Storage of plant protection products in farms: minimum safety requirements].

    Dutto, Moreno; Alfonzo, Santo; Rubbiani, Maristella

    2012-01-01

    Failure to comply with requirements for proper storage and use of pesticides in farms can be extremely hazardous and the risk of accidents involving farm workers, other persons and even animals is high. There are still wide differences in the interpretation of the concept of "securing or making safe", by workers in this sector. One of the critical points detected, particularly in the fruit sector, is the establishment of an adequate storage site for plant protection products. The definition of "safe storage of pesticides" is still unclear despite the recent enactment of Legislative Decree 81/2008 regulating health and work safety in Italy. In addition, there are no national guidelines setting clear minimum criteria for storage of plant protection products in farms. The authors, on the basis of their professional experience and through analysis of recent legislation, establish certain minimum safety standards for storage of pesticides in farms.

  1. Focus on the studies in support of fire safety analysis. IRSN modelling approach for nuclear facilities

    Espargilliere, Julien; Meyrand, Raphael; Vinot, Thierry [Institut de Radioprotection et de Surete Nucleaire (IRSN), Fontenay-aux-Roses (France)

    2015-12-15

    For a fire safety analysis, in order to comply with nuclear safety goals, a nuclear fuel facility operator has to define the elements important for safety to be maintained, even in the case of a fire. One of the key points of this fire analysis is the assessment of possible fire scenarios in the facility. This paper presents the IRSN method applied to a case study to assess fire scenarios which have the most harmful effects on safety targets. The layout consists in a central room (fire cell) containing three glove boxes with radioactive material and three electrical cabinets. This room is linked to two connecting compartments (the fire cell and these two compartments define the containment cell) and then to two corridors. Each room is equipped with a mechanical ventilation system, and a pressure cascade is established from the corridors to the central room. A fire scenario was studied with fire ignition occurring in an electrical cabinet. This scenario has a set of safety goals (prevention of fire cell and containment device failure, propagation of the fire). This case study was conducted with the IRSN code SYLVIA based on two zones modelling. Safety goals were associated with key parameters and performance criteria to be fulfilled. Modelling assumptions were defined in order to maximize physical effects of the fire. Sensitivity studies were also conducted on key parameters such as oxygen limitation, equivalent-fuel definition. Eventually, a critical analysis of the code models was carried out.

  2. Waste Encapsulation and Storage Facility interim operational safety requirements

    Covey, L I

    2000-01-01

    The Interim Operational Safety Requirements (IOSRs) for the Waste Encapsulation and Storage Facility (WESF) define acceptable conditions, safe boundaries, bases thereof, and management or administrative controls required to ensure safe operation during receipt and inspection of cesium and strontium capsules from private irradiators; decontamination of the capsules and equipment; surveillance of the stored capsules; and maintenance activities. Controls required for public safety, significant defense-in-depth, significant worker safety, and for maintaining radiological consequences below risk evaluation guidelines (EGs) are included.

  3. Integrated system of safety features for spent fuel interim storage

    Pantazi, Doina; Stanciu, Marcela; Mateescu, Silvia; Marin, Ion

    1999-01-01

    The design of the spent fuel interim storage facility (SFISF) must meet the applicable safety requirements in order to ensure radiological protection of the personnel, public and environment during all phases of the facility. To elaborate the safety documentation necessary for licensing, we were trying to chose the most appropriate approach related to safety features for SFISF, based on national and international regulations, standards and recommendations, as well as on the experience of other countries with similar facilities and finally, on our own experience in designing other nuclear objectives in Romania. The paper presents the issues that we consider important for the safety evaluation and are developed as a detailed diagram. The diagram contains in a logical succession the following issues: - fundamental principles of radioprotection; - fundamental safety principles of radioactive waste management; - safety objectives of SFISF; - safety criteria for SFISF; - safety requirements for SFISF; - siting criteria for SFISF; - siting requirements for SFISF. (authors)

  4. A computer code SPHINCS for sodium fire safety evaluation

    Yamaguchi, Akira

    2000-01-01

    A computer code SPHINCS solves coupled phenomena of thermal-hydraulics and sodium fire based on a multi-zone model. It deals with arbitrary number of rooms each of which is connected mutually by doorway and penetrations. With regard to the combustion phenomena, flame sheet model and liquid droplet combustion model are used for pool and spray fire, respectively, with the chemical equilibrium model using Gibbs free energy minimization method. The chemical reaction and mass and heat transfer are solved interactively. A specific feature of SPHINCS is detailed representation of thermal-hydraulics of a sodium pool and a steel liner, which is placed on the floor to prevent sodium-concrete contact. The author analyzed a series of pool combustion experiments, in which gas and liner temperatures are measured in detail. It has been found that good agreement is obtained and the SPHINCS has been validated with regard to the pool combustion phenomena. Further research needs are identified for the pool spreading modeling considering thermal deformation of liner and measurement of pool fluidity property of a mixture of liquid sodium and reaction products. SPHINCS code is to be used mainly in the safety evaluation of the consequence of sodium fire accident of liquid metal cooled fast reactor. (author)

  5. The testing of the in situ fire extinction system of the Trawsfynydd splitter debris storage package

    Newman, R.N.

    1987-01-01

    The proposed design of a Magnox splitter debris storage drum for Trawsfynydd incorporates an in situ solid fire extinguishant Graphex CK23 on the debris surface. This is an interlamellar graphite residue compound that intumesces when heated to provide an air-restricting layer. Two series of fire tests with the extinguishant in place have been carried out on full sized drums containing unirradiated splitter debris, to demonstrate the effectiveness of the system. (author)

  6. Engineering judgement and bridging the fire safety gap in existing nuclear facilities

    Qamheiah, G.; Wu, Y., E-mail: gqamheiah@plcfire.com, E-mail: dwu@plcfire.com [PLC Fire Safety Solutions, Mississauga, ON (Canada)

    2014-07-01

    Canadian nuclear power plants were constructed in the 1960's through the 1980's. Fire safety considerations were largely based on guidance from general building and fire codes in effect at the time. Since then, nuclear specific fire safety standards have been developed and adopted by the Regulator, increasing the expected level of fire safety in the process. Application of the standards to existing plants was largely limited to operational requirements viewed as retroactive. However, as existing facilities undergo modifications or refurbishment for the purpose of life extension, the expectation is that the design requirements of these fire safety standards also be satisfied. This creates considerable challenges for existing nuclear power plants as fire safety requirements such as those intended to assure means for safe egress, prevention of fire spread and protection of redundancy rely upon fire protection features that are inherent in the physical infrastructural design. This paper focuses on the methodology for conducting fire safety gap analyses on existing plants, and the integral role that engineering judgement plays in the development of viable and cost effective solutions to achieve the objectives of the current fire safety standards. (author)

  7. Technical Safety Requirements for the Waste Storage Facilities

    Larson, H L

    2007-01-01

    This document contains Technical Safety Requirements (TSR) for the Radioactive and Hazardous Waste Management (RHWM) WASTE STORAGE FACILITIES, which include Area 612 (A612) and the Decontamination and Waste Treatment Facility (DWTF) Storage Area at Lawrence Livermore National Laboratory (LLNL). The TSRs constitute requirements regarding the safe operation of the WASTE STORAGE FACILITIES. These TSRs are derived from the Documented Safety Analysis for the Waste Storage Facilities (DSA) (LLNL 2006). The analysis presented therein determined that the WASTE STORAGE FACILITIES are low-chemical hazard, Hazard Category 2 non-reactor nuclear facilities. The TSRs consist primarily of inventory limits and controls to preserve the underlying assumptions in the hazard and accident analyses. Further, appropriate commitments to safety programs are presented in the administrative controls sections of the TSRs. The WASTE STORAGE FACILITIES are used by RHWM to handle and store hazardous waste, TRANSURANIC (TRU) WASTE, LOW-LEVEL WASTE (LLW), mixed waste, California combined waste, nonhazardous industrial waste, and conditionally accepted waste generated at LLNL as well as small amounts from other U.S. Department of Energy (DOE) facilities, as described in the DSA. In addition, several minor treatments (e.g., drum crushing, size reduction, and decontamination) are carried out in these facilities. The WASTE STORAGE FACILITIES are located in two portions of the LLNL main site. A612 is located in the southeast quadrant of LLNL. The A612 fenceline is approximately 220 m west of Greenville Road. The DWTF Storage Area, which includes Building 693 (B693), Building 696 Radioactive Waste Storage Area (B696R), and associated yard areas and storage areas within the yard, is located in the northeast quadrant of LLNL in the DWTF complex. The DWTF Storage Area fenceline is approximately 90 m west of Greenville Road. A612 and the DWTF Storage Area are subdivided into various facilities and storage

  8. Technical Safety Requirements for the Waste Storage Facilities

    Larson, H L

    2007-09-07

    This document contains Technical Safety Requirements (TSR) for the Radioactive and Hazardous Waste Management (RHWM) WASTE STORAGE FACILITIES, which include Area 612 (A612) and the Decontamination and Waste Treatment Facility (DWTF) Storage Area at Lawrence Livermore National Laboratory (LLNL). The TSRs constitute requirements regarding the safe operation of the WASTE STORAGE FACILITIES. These TSRs are derived from the Documented Safety Analysis for the Waste Storage Facilities (DSA) (LLNL 2006). The analysis presented therein determined that the WASTE STORAGE FACILITIES are low-chemical hazard, Hazard Category 2 non-reactor nuclear facilities. The TSRs consist primarily of inventory limits and controls to preserve the underlying assumptions in the hazard and accident analyses. Further, appropriate commitments to safety programs are presented in the administrative controls sections of the TSRs. The WASTE STORAGE FACILITIES are used by RHWM to handle and store hazardous waste, TRANSURANIC (TRU) WASTE, LOW-LEVEL WASTE (LLW), mixed waste, California combined waste, nonhazardous industrial waste, and conditionally accepted waste generated at LLNL as well as small amounts from other U.S. Department of Energy (DOE) facilities, as described in the DSA. In addition, several minor treatments (e.g., drum crushing, size reduction, and decontamination) are carried out in these facilities. The WASTE STORAGE FACILITIES are located in two portions of the LLNL main site. A612 is located in the southeast quadrant of LLNL. The A612 fenceline is approximately 220 m west of Greenville Road. The DWTF Storage Area, which includes Building 693 (B693), Building 696 Radioactive Waste Storage Area (B696R), and associated yard areas and storage areas within the yard, is located in the northeast quadrant of LLNL in the DWTF complex. The DWTF Storage Area fenceline is approximately 90 m west of Greenville Road. A612 and the DWTF Storage Area are subdivided into various facilities and storage

  9. Criticality safety analysis of the NPP Krsko storage racks

    Kromar, M.; Kurincic, B.

    2002-01-01

    NPP Krsko is going to increase the capacity of the spent fuel storage pool by replacement of the existing racks with high-density racks. This will be the second reracking campaign since 1983 when storage was increased from 180 to 828 storage locations. The pool capacity will increase from 828 to 1694 with partial reracking by the spring 2003. The installed capacity will be sufficient for the current design plant lifetime. Complete reracking of the spent fuel pool will additionally increase capacity to 2321 storage locations. The design, rack manufacturing and installation has been awarded to the Framatome ANP GmbH. Burnup credit methodology, which was approved by the Slovenian Nuclear Safety Administration in previous licensing of existing racks, will be again implemented in the licensing process with the recent methodology improvements. Specific steps of the criticality safety analysis and representative results are presented in the paper.(author)

  10. Fire and evacuation drills make the CERN safety plans work

    Antonella Del Rosso

    2013-01-01

    Regular drills are a way of making sure that we are ready and able to react in the event of a fire or other adverse event. They are also a demanding test of all the technical and organisational measures in place to allow the quick and safe evacuation of buildings. Recently, large-scale drills took place in Building 40 and at Point 5 underground.   Group photo at Point 5, after the common evacuation drill. The ability to react to unexpected, adverse events relies in particular on training. This is why CERN’s safety teams organise regular drills. One of the most recent exercises took place on 26 March in Building 40. “Building 40 is a modern building fully equipped against fire, with two emergency exits in the central atrium. We also have 29 emergency guides distributed on each floor to guide people out of their offices,” says Kate Richardson, Territorial Safety Officer of the building. “The drills are very useful for testing the building's insta...

  11. Overview of IAEA guidelines for fire safety inspection and operation in nuclear power plants

    Mowrer, D.S.

    1998-01-01

    In 1992, the International Atomic Energy Agency began an ambitious project on fire safety in nuclear power plants. The purpose of this ongoing project is to provide specific guidance on compliance with the requirements set forth through the IAEA Nuclear Safety Standards program established in 1974. The scope of the Fire Safety project encompasses several tasks, including the development of new standards and guidelines to assist Member States in assessing the level of fire safety in existing plants. Five new Safety Practices, one new Safety Guide and a Technical Document have been developed for use by the fire safety community. The primary intent of these new documents is to provide detailed guidance and a consistent format for the assessment of the overall level of fire safety being provided in existing nuclear power plants around the world and especially in developing countries. Sufficient detail is provided in the Safety Guide and Safety Practices to allow technically knowledgeable plant personnel, outside consultants or other technical experts to assess the adequacy of fire safety within the plant facilities. This paper describes topics addressed by each of the IAEA Fire Safety documents and discussed the relationship of each document to others in the series. (author)

  12. What safety indicators for a storage in deep geologic deposit?

    Crouail, P.; Schneider, T.; Mure, J.M.; Voinis, S.

    1999-01-01

    Indicators must allow to discriminate and compare different options of facility conception and help the decision-makers in their choices. In the case of a deep storage, these indicators can also allow a comparison in terms of impact with other existing industrial systems (thermal or nuclear power plants, uranium ores) or even the natural radioactivity. Through Swedish and Canadian examples, the presentation makes an inventory of indicators that could be kept in a safety analysis of a deep storage. (N.C.)

  13. Canister Storage Building (CSB) Technical Safety Requirements

    KRAHN, D.E.

    2000-01-01

    The purpose of this section is to explain the meaning of logical connectors with specific examples. Logical connectors are used in Technical Safety Requirements (TSRs) to discriminate between, and yet connect, discrete Conditions, Required Actions, Completion Times, Surveillances, and Frequencies. The only logical connectors that appear in TSRs are AND and OR. The physical arrangement of these connectors constitutes logical conventions with specific meanings

  14. The assessment of fire safety of cast iron structures in historical buildings: Theory and practice

    Twilt, L.; Hunen, M. van

    2000-01-01

    The assessment of structural fire safety of cast iron structures in historical buildings is difficult because the available information on the fire behaviour is limited, whilst the fire design assumptions (if any) often are not well docu-mented. A complicating factor with regard to protective

  15. Evaluating a smartphone application to improve child passenger safety and fire safety knowledge and behaviour.

    Omaki, Elise; Shields, Wendy C; McDonald, Eileen; Aitken, Mary E; Bishai, David; Case, James; Gielen, Andrea

    2017-02-01

    Although proven measures for reducing injury due to motor vehicle collision and residential fires exist, the number of families properly and consistently using child passenger restraints and smoke alarms remains low. This paper describes the design of the Safety In Seconds (SIS) 2.0 study, which aims to evaluate the impact of a smartphone app on parents' use of child restraints and smoke alarms. SIS is a multisite randomised controlled trial. Participants are parents of children aged 4-7 years who are visiting the Pediatric Emergency Department or Pediatric Trauma Service. Parents are randomised to receive tailored education about child passenger safety or about fire safety via the SIS smartphone app. A baseline and two follow-up surveys at 3 months and 6 months are conducted. Primary outcomes are: (1) having the correct child restraint for the child's age and size; (2) restraining the child in the back seat of the car; (3) buckling the child up for every ride; (4) having the restraint inspected by a child passenger safety technician; (5) having a working smoke alarm on every level of the home; (6) having hard-wired or lithium battery smoke alarms; (7) having and (8) practising a fire escape plan. Finding ways to communicate with parents about child passenger and fire safety continues to be a research priority. This study will contribute to the evidence about how to promote benefits of proper and consistent child restraint and smoke alarm use. NCT02345941; Pre-results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  16. Safety study of fire protection for nuclear fuel cycle facility

    NONE

    2013-08-15

    Based on the investigation of fire protection standards for domestic and foreign nuclear facilities, the fire protection guideline for nuclear fuel cycle facility has been completed. In 2012, trial operation is started by private company using the guideline. In addition, the acquisition of fire evaluation data for a components (electric cable) targeted for spread of fire and the evaluation model of fire source were continued for the fire hazard analysis (FHA). (author)

  17. Safety study of fire protection for nuclear fuel cycle facility

    2013-01-01

    Based on the investigation of fire protection standards for domestic and foreign nuclear facilities, the fire protection guideline for nuclear fuel cycle facility has been completed. In 2012, trial operation is started by private company using the guideline. In addition, the acquisition of fire evaluation data for a components (electric cable) targeted for spread of fire and the evaluation model of fire source were continued for the fire hazard analysis (FHA). (author)

  18. Fires in storages of LFO: Analysis of hazard of structural collapse of steel–aluminium containers

    Rebec, A., E-mail: andrej.rebec@zag.si [ZAG – Slovenian National Building and Civil Engineering Institute, Fire Laboratory and Fire Engineering, Dimičeva 12, SI-1000 Ljubljana (Slovenia); Kolšek, J. [ZAG – Slovenian National Building and Civil Engineering Institute, Fire Laboratory and Fire Engineering, Dimičeva 12, SI-1000 Ljubljana (Slovenia); Plešec, P. [ZAG – Slovenian National Building and Civil Engineering Institute, Laboratory for the Efficient Use of Energy, Renewables, and Acoustics, Dimičeva 12, SI-1000 Ljubljana (Slovenia)

    2016-04-05

    Highlights: • Pool fires of light fuel oil (LFO) in above-ground storages are discussed. • Hazard of structural collapse of steel–aluminium containers of LFO is analysed. • Experiments were performed for determination of heat radiation from LFO pool fires. • Elasto-plastic material data were derived with tests for 3xxx and 6xxx aluminium. • High-temperature creep of 3xxx aluminium is discussed. - Abstract: Pool fires of light fuel oil (LFO) in above-ground storages with steel–aluminium containers are discussed. A model is developed for assessments of risks of between-tank fire spread. Radiative effects of the flame body are accounted for by a solid flame radiation model. Thermal profiles evolved due to fire in the adjacent tanks and their consequential structural response is pursued in an exact (materially and geometrically non-linear) manner. The model's derivation is demonstrated on the LFO tank storage located near the Port of Koper (Slovenia). In support of the model, data from literature are adopted where appropriate. Analytical expressions are derived correspondingly for calculations of emissive characteristics of LFO pool fires. Additional data are collected from experiments. Fire experiments conducted on 300 cm diameter LFO pans and at different wind speeds and high-temperature uniaxial tension tests of the analysed aluminium alloys types 3xxx and 6xxx are presented. The model is of an immediate fire engineering practical value (risk analyses) or can be used for further research purposes (e.g. sensitivity and parametric studies). The latter use is demonstrated in the final part of the paper discussing possible effects of high-temperature creep of 3xxx aluminium.

  19. Advanced methods for a probabilistic safety analysis of fires. Development of advanced methods for performing as far as possible realistic plant specific fire risk analysis (fire PSA)

    Hofer, E.; Roewekamp, M.; Tuerschmann, M.

    2003-07-01

    In the frame of the research project RS 1112 'Development of Methods for a Recent Probabilistic Safety Analysis, Particularly Level 2' funded by the German Federal Ministry of Economics and Technology (BMWi), advanced methods, in particular for performing as far as possible realistic plant specific fire risk analyses (fire PSA), should be developed. The present Technical Report gives an overview on the methodologies developed in this context for assessing the fire hazard. In the context of developing advanced methodologies for fire PSA, a probabilistic dynamics analysis with a fire simulation code including an uncertainty and sensitivity study has been performed for an exemplary scenario of a cable fire induced by an electric cabinet inside the containment of a modern Konvoi type German nuclear power plant taking into consideration the effects of fire detection and fire extinguishing means. With the present study, it was possible for the first time to determine the probabilities of specified fire effects from a class of fire events by means of probabilistic dynamics supplemented by uncertainty and sensitivity analyses. The analysis applies a deterministic dynamics model, consisting of a dynamic fire simulation code and a model of countermeasures, considering effects of the stochastics (so-called aleatory uncertainties) as well as uncertainties in the state of knowledge (so-called epistemic uncertainties). By this means, probability assessments including uncertainties are provided to be used within the PSA. (orig.) [de

  20. Radiation safety design for SSRL storage ring

    Khater, Hesham [Radiation Protection Department, Stanford Linear Accelerator Center (SLAC), 2575 Sand Hill Road, Menlo Park, CA 94025 (United States)]. E-mail: khater1@llnl.gov; Liu, James [Radiation Protection Department, Stanford Linear Accelerator Center (SLAC), 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Fasso, Alberto [Radiation Protection Department, Stanford Linear Accelerator Center (SLAC), 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Prinz, Alyssa [Radiation Protection Department, Stanford Linear Accelerator Center (SLAC), 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Rokni, Sayed [Radiation Protection Department, Stanford Linear Accelerator Center (SLAC), 2575 Sand Hill Road, Menlo Park, CA 94025 (United States)

    2006-12-15

    In 2003, the Stanford Synchrotron Radiation Laboratory (SSRL) had upgraded its storage ring to a 3rd generation storage ring (SPEAR3). SPEAR3 is deigned to operate at 500-mA stored beam current and 3-GeV energy. The 234-m circumference SPEAR3 ring utilizes 60-cm-thick concrete lateral walls, 30-cm-thick concrete roof, as well as 60- or 90-cm-thick concrete ratchet walls. A total of 3.5x10{sup 15}e{sup -}/y will be injected into the ring with an injection power of 4W and an injection efficiency of 75%. Normal beam losses occur due to both injection and stored beam operations in the total of 20 low loss as well as 3 high loss limiting apertures. During the 6-min injection period, an instantaneous power loss of 0.05W occurs at each low loss aperture. When averaged over the operational year, the loss of both the injection and the stored beams is equivalent to an average loss of 2mW at each low loss aperture. On the other hand, the average losses in the high loss apertures are 16mW for the injection septum, 47mW for the beam abort dump, and 13mW for the ring stoppers. The shielding requirements for losses in the new ring were based on a generic approach that used both FLUKA Monte Carlo particle generation and transport code and empirical computer codes and formulae.

  1. FDS Modeling of the Sensitivity of the Smoke Potential Values used in Fire Safety Strategies

    Corches, Andrei-Mircea; Ulriksen, Lene; Jomaas, Grunde

    2014-01-01

    To investigate the sensitivity of Fire Dynamics Simulator (FDS) with respect to the input parameters that are used to define the optical properties of the smoke, a parametric study was performed for relevant fire scenarios in an open plan office building. The parametric study mainly focuses on th...... to defining the design fires will reduce the sensitivity of the numerical fire simulation and further reduce the risk of overestimating the evacuation safety level (ESL) of the building....

  2. Technical Safety Requirements for the Waste Storage Facilities

    Laycak, D.T.

    2010-01-01

    This document contains Technical Safety Requirements (TSR) for the Radioactive and Hazardous Waste Management (RHWM) WASTE STORAGE FACILITIES, which include Area 625 (A625) and the Decontamination and Waste Treatment Facility (DWTF) Storage Area at Lawrence Livermore National Laboratory (LLNL). The TSRs constitute requirements regarding the safe operation of the WASTE STORAGE FACILITIES. These TSRs are derived from the Documented Safety Analysis for the Waste Storage Facilities (DSA) (LLNL 2009). The analysis presented therein determined that the WASTE STORAGE FACILITIES are low-chemical hazard, Hazard Category 2 non-reactor nuclear facilities. The TSRs consist primarily of inventory limits and controls to preserve the underlying assumptions in the hazard and accident analyses. Further, appropriate commitments to safety programs are presented in the administrative controls sections of the TSRs. The WASTE STORAGE FACILITIES are used by RHWM to handle and store hazardous waste, TRANSURANIC (TRU) WASTE, LOW-LEVEL WASTE (LLW), mixed waste, California combined waste, nonhazardous industrial waste, and conditionally accepted waste generated at LLNL as well as small amounts from other U.S. Department of Energy (DOE) facilities, as described in the DSA. In addition, several minor treatments (e.g., size reduction and decontamination) are carried out in these facilities. The WASTE STORAGE FACILITIES are located in two portions of the LLNL main site. A625 is located in the southeast quadrant of LLNL. The A625 fenceline is approximately 225 m west of Greenville Road. The DWTF Storage Area, which includes Building 693 (B693), Building 696 Radioactive Waste Storage Area (B696R), and associated yard areas and storage areas within the yard, is located in the northeast quadrant of LLNL in the DWTF complex. The DWTF Storage Area fenceline is approximately 90 m west of Greenville Road. A625 and the DWTF Storage Area are subdivided into various facilities and storage areas, consisting

  3. Technical Safety Requirements for the Waste Storage Facilities

    Laycak, D T

    2008-06-16

    This document contains Technical Safety Requirements (TSR) for the Radioactive and Hazardous Waste Management (RHWM) WASTE STORAGE FACILITIES, which include Area 625 (A625) and the Decontamination and Waste Treatment Facility (DWTF) Storage Area at Lawrence Livermore National Laboratory (LLNL). The TSRs constitute requirements regarding the safe operation of the WASTE STORAGE FACILITIES. These TSRs are derived from the 'Documented Safety Analysis for the Waste Storage Facilities' (DSA) (LLNL 2008). The analysis presented therein determined that the WASTE STORAGE FACILITIES are low-chemical hazard, Hazard Category 2 non-reactor nuclear facilities. The TSRs consist primarily of inventory limits and controls to preserve the underlying assumptions in the hazard and accident analyses. Further, appropriate commitments to safety programs are presented in the administrative controls sections of the TSRs. The WASTE STORAGE FACILITIES are used by RHWM to handle and store hazardous waste, TRANSURANIC (TRU) WASTE, LOW-LEVEL WASTE (LLW), mixed waste, California combined waste, nonhazardous industrial waste, and conditionally accepted waste generated at LLNL as well as small amounts from other U.S. Department of Energy (DOE) facilities, as described in the DSA. In addition, several minor treatments (e.g., size reduction and decontamination) are carried out in these facilities. The WASTE STORAGE FACILITIES are located in two portions of the LLNL main site. A625 is located in the southeast quadrant of LLNL. The A625 fenceline is approximately 225 m west of Greenville Road. The DWTF Storage Area, which includes Building 693 (B693), Building 696 Radioactive Waste Storage Area (B696R), and associated yard areas and storage areas within the yard, is located in the northeast quadrant of LLNL in the DWTF complex. The DWTF Storage Area fenceline is approximately 90 m west of Greenville Road. A625 and the DWTF Storage Area are subdivided into various facilities and storage areas

  4. Using Modeling and Rehearsal to Teach Fire Safety to Children with Autism

    Garcia, David; Dukes, Charles; Brady, Michael P.; Scott, Jack; Wilson, Cynthia L.

    2016-01-01

    We evaluated the efficacy of an instructional procedure to teach young children with autism to evacuate settings and notify an adult during a fire alarm. A multiple baseline design across children showed that an intervention that included modeling, rehearsal, and praise was effective in teaching fire safety skills. Safety skills generalized to…

  5. Firefighters United for Safety, Ethics, and Ecology (FUSEE): Torchbearers for a new fire management paradigm

    Timothy Ingalsbee; Joseph Fox; Patrick Withen

    2007-01-01

    Firefighters United for Safety, Ethics, and Ecology (FUSEE) is a nonprofit organization promoting safe, ethical, ecological wildland fire management. FUSEE believes firefighter and community safety are ultimately interdependent with ethical public service, wildlands protection, and ecological restoration of fire-adapted ecosystems. Our members include current, former,...

  6. 48 CFR 245.7311-2 - Safety, security, and fire regulations.

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Safety, security, and fire regulations. 245.7311-2 Section 245.7311-2 Federal Acquisition Regulations System DEFENSE ACQUISITION... Inventory 245.7311-2 Safety, security, and fire regulations. ...

  7. Technical Safety Requirements for the Waste Storage Facilities May 2014

    Laycak, D. T. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2014-04-16

    This document contains the Technical Safety Requirements (TSR) for the Radioactive and Hazardous Waste Management (RHWM) WASTE STORAGE FACILITIES, which include Area 625 (A625) and the Building 693 (B693) Yard Area of the Decontamination and Waste Treatment Facility (DWTF) at LLNL. The TSRs constitute requirements for safe operation of the WASTE STORAGE FACILITIES. These TSRs are derived from the Documented Safety Analyses for the Waste Storage Facilities (DSA) (LLNL 2011). The analysis presented therein concluded that the WASTE STORAGE FACILITIES are low-chemical hazard, Hazard Category 2 non-reactor nuclear facilities. The TSRs consist primarily of inventory limits and controls to preserve the underlying assumptions in the hazard and accident analyses. Further, appropriate commitments to safety programs are presented in the administrative controls sections of the TSRs. The WASTE STORAGE FACILITIES are used by RHWM to handle and store hazardous waste, TRANSURANIC (TRU) WASTE, LOW-LEVEL WASTE (LLW), mixed waste, California combined waste, nonhazardous industrial waste, and conditionally accepted waste generated at LLNL as well as small amounts of waste from other DOE facilities, as described in the DSA. In addition, several minor treatments (e.g., size reduction and decontamination) are carried out in these facilities.

  8. Technical Safety Requirements for the Waste Storage Facilities May 2014

    Laycak, D. T.

    2014-01-01

    This document contains the Technical Safety Requirements (TSR) for the Radioactive and Hazardous Waste Management (RHWM) WASTE STORAGE FACILITIES, which include Area 625 (A625) and the Building 693 (B693) Yard Area of the Decontamination and Waste Treatment Facility (DWTF) at LLNL. The TSRs constitute requirements for safe operation of the WASTE STORAGE FACILITIES. These TSRs are derived from the Documented Safety Analyses for the Waste Storage Facilities (DSA) (LLNL 2011). The analysis presented therein concluded that the WASTE STORAGE FACILITIES are low-chemical hazard, Hazard Category 2 non-reactor nuclear facilities. The TSRs consist primarily of inventory limits and controls to preserve the underlying assumptions in the hazard and accident analyses. Further, appropriate commitments to safety programs are presented in the administrative controls sections of the TSRs. The WASTE STORAGE FACILITIES are used by RHWM to handle and store hazardous waste, TRANSURANIC (TRU) WASTE, LOW-LEVEL WASTE (LLW), mixed waste, California combined waste, nonhazardous industrial waste, and conditionally accepted waste generated at LLNL as well as small amounts of waste from other DOE facilities, as described in the DSA. In addition, several minor treatments (e.g., size reduction and decontamination) are carried out in these facilities.

  9. An assessment of the impact of home safety assessments on fires and fire-related injuries: a case study of Cheshire Fire and Rescue Service.

    Arch, B N; Thurston, M N

    2013-06-01

    Deaths and injuries related to fires are largely preventable events. In the UK, a plethora of community-based fire safety initiatives have been introduced over the last 25 years, often led by fire and rescue services, to address this issue. This paper focuses on one such initiative--home safety assessments (HSAs). Cheshire Fire and Rescue Service (in England) implemented a uniquely large-scale HSA intervention. This paper assesses its effectiveness. The impact of HSAs was assessed in relation to three outcomes: accidental dwelling fires (ADFs), ADFs contained and injuries arising from ADFs. A two-period comparison in fire-related rates of incidences in Cheshire between 2002 and 2011 was implemented, using Poisson regression and adjusting for the national temporal trend using a control group comprising the 37 other English non-metropolitan fire-services. Significant reductions were observed in rates of ADFs [incidence rate ratios (IRR): 0.79, 95% confidence interval (CI): 0.74-0.83, P fires contained to room of origin. There is strong evidence to suggest that the intervention was successful in reducing domestic fires and related injuries.

  10. Safety analysis of the existing 804 and 845 firing facilities

    Odell, B.N.

    1986-01-01

    A safety analysis was performed to determine if normal operations and/or potential accidents at the 804 and 845 Firing Facilities at Site 300 could present undue hazards to the general public, peronnel at Site 300, or have an adverse effect on the environment. The normal operation and credible accident that might have an effect on these facilities or have off-site consequence were considered. It was determined by this analysis that all but one of the hazards were either low or of the type or magnitude routinely encountered and/or accepted by the public. The exception was explosives. Since this hazard has the potential for causing significant on-site and minimum off-site consequences, Bunkers 804 and 845 have been classified as moderate hazard facilties per DOE Order 5481.1A. This safety analysis concluded that the operation at these facilities will present no undue risk to the health and safety of LLNL employees or the public

  11. 33 CFR 147.847 - Safety Zone; BW PIONEER Floating Production, Storage, and Offloading System Safety Zone.

    2010-07-01

    ... Production, Storage, and Offloading System Safety Zone. 147.847 Section 147.847 Navigation and Navigable... ZONES § 147.847 Safety Zone; BW PIONEER Floating Production, Storage, and Offloading System Safety Zone. (a) Description. The BW PIONEER, a Floating Production, Storage and Offloading (FPSO) system, is in...

  12. Safety of Long-term Interim Storage Facilities - Workshop Proceedings

    2014-01-01

    The objective of this workshop was to discuss and review current national activities, plans and regulatory approaches for the safety of long term interim storage facilities dedicated to spent nuclear fuel (SF), high level waste (HLW) and other radioactive materials with prolonged storage regimes. It was also intended to discuss results of experiments and to identify necessary R and D to confirm safety of fuel and cask during the long-term storage. Safety authorities and their Technical Support Organisation (TSO), Fuel Cycle Facilities (FCF) operating organisations and international organisations were invited to share information on their approaches, practices and current developments. The workshop was organised in an opening session, three technical sessions, and a conclusion session. The technical sessions were focused on: - National approaches for long term interim storage facilities; - Safety requirements, regulatory framework and implementation issues; - Technical issues and operational experience, needs for R and D. Each session consisted of a number of presentations followed by a panel discussion moderated by the session Chairs. A summary of each session and subsequent discussion that ensued are provided as well as a summary of the results of the workshop with the text of the papers given and presentations made

  13. 30 CFR 75.1912 - Fire suppression systems for permanent underground diesel fuel storage facilities.

    2010-07-01

    ... Diesel-Powered Equipment § 75.1912 Fire suppression systems for permanent underground diesel fuel storage... system by a nationally recognized independent testing laboratory and appropriate for installation at a... recommended inspection and maintenance program and as required by the nationally recognized independent...

  14. Documented Safety Analysis for the Waste Storage Facilities March 2010

    Laycak, D T

    2010-03-05

    This Documented Safety Analysis (DSA) for the Waste Storage Facilities was developed in accordance with 10 CFR 830, Subpart B, 'Safety Basis Requirements,' and utilizes the methodology outlined in DOE-STD-3009-94, Change Notice 3. The Waste Storage Facilities consist of Area 625 (A625) and the Decontamination and Waste Treatment Facility (DWTF) Storage Area portion of the DWTF complex. These two areas are combined into a single DSA, as their functions as storage for radioactive and hazardous waste are essentially identical. The B695 Segment of DWTF is addressed under a separate DSA. This DSA provides a description of the Waste Storage Facilities and the operations conducted therein; identification of hazards; analyses of the hazards, including inventories, bounding releases, consequences, and conclusions; and programmatic elements that describe the current capacity for safe operations. The mission of the Waste Storage Facilities is to safely handle, store, and treat hazardous waste, transuranic (TRU) waste, low-level waste (LLW), mixed waste, combined waste, nonhazardous industrial waste, and conditionally accepted waste generated at LLNL (as well as small amounts from other DOE facilities).

  15. Documented Safety Analysis for the Waste Storage Facilities

    Laycak, D

    2008-06-16

    This documented safety analysis (DSA) for the Waste Storage Facilities was developed in accordance with 10 CFR 830, Subpart B, 'Safety Basis Requirements', and utilizes the methodology outlined in DOE-STD-3009-94, Change Notice 3. The Waste Storage Facilities consist of Area 625 (A625) and the Decontamination and Waste Treatment Facility (DWTF) Storage Area portion of the DWTF complex. These two areas are combined into a single DSA, as their functions as storage for radioactive and hazardous waste are essentially identical. The B695 Segment of DWTF is addressed under a separate DSA. This DSA provides a description of the Waste Storage Facilities and the operations conducted therein; identification of hazards; analyses of the hazards, including inventories, bounding releases, consequences, and conclusions; and programmatic elements that describe the current capacity for safe operations. The mission of the Waste Storage Facilities is to safely handle, store, and treat hazardous waste, transuranic (TRU) waste, low-level waste (LLW), mixed waste, combined waste, nonhazardous industrial waste, and conditionally accepted waste generated at LLNL (as well as small amounts from other DOE facilities).

  16. Influence of long-term storage on fire hazard properties of metal nanopowders

    Kyrmakova, O. S.; Sechin, A. I.; Nazarenko, O. B.

    2017-08-01

    The production and application of nanomaterials is rapidly expanding. Therefore the problem of their properties change during long-term storage becomes essential. The properties of metal nanopowders after long-term storage under ambient conditions were studied and the results are presented in this work. The aluminum, iron, zinc, and copper nanopowders produced by the method of electrical explosion of wires were investigated in this work. The investigation was carried out by X-ray and thermal analysis. The estimation of the flame propagation velocity in the bulk layer of nanopowders was carried out. The characteristics of the nanopowders of nanometals studied are given in terms of their fire hazard. The results can be used for diagnostic of fire hazard of nanomaterials and protection of the enterprises against fire and explosion.

  17. Fire Protection of Weapon Storage and Water Mist Redundancy Philosophies

    2012-11-01

    criteria me system ged system ozzles dummy tor d, insulated titute of Swe stems pedo pipe Date 2012 den Refere -03-31 P90 nce 0038-04...test wit tion test wit ution test wi t system, 10 st system, 5 m, 5 bar, 50 , 10 bar, 50 ummy, free- edo dummy pedo dummy pedo dummy ummy, dren...systems usi lower volum pedo dumm temperature discharge d ion. h Institute ynamics dström Date 2012 den ater mist/wa ests indicate fire

  18. Building Fire Safety Audit at Faculty X, University of Indonesia, Year 2006

    Fatma Lestari

    2010-10-01

    Full Text Available Fire may cause loss of life, material and valuable assets. The objective of this study is to conduct audit for fire safety and emergency response in the building at Faculty X, University of Indonesia, Depok. The audit results on the building fire safety facilities including emergency response and preparedness are then compared to the Building Code Australia (BCA and Indonesian regulation on the building fire safety (Kep.MenPU.No 10 and 11/KPTS/2000. The building selected are Building A, B, C, D, F and G. Building classification for A, B, D, F and G are classified as Class 5, while Building C is classified as Class 9b. Variable which are evaluated including emergency exit, building structure, fire alarm and detector, communication and fire warning system, evacuation procedure, portable fire extinguishers, hydrant, sprinkler, and emergency response preparedness. Results suggested that emergency exit is locked, and this is not comply to the regulation. Building structure has been complied to the regulation since it was made of concrete. Fire detector and alarm only provided in Building G, while other building is not available. There is no evacuation procedure available. Portable fire extinguisher has been available in all the building. Hydrant an sprinkler only available in building G. There is no emergency response preparedness in this faculty. In conclusion, the fire safety facilities in this faculty need to be improved.

  19. Energy Storage System Safety: Plan Review and Inspection Checklist

    Cole, Pam C (PNNL); Conover, David R (PNNL)

    2017-03-01

    Codes, standards, and regulations (CSR) governing the design, construction, installation, commissioning, and operation of the built environment are intended to protect the public health, safety, and welfare. While these documents change over time to address new technology and new safety challenges, there is generally some lag time between the introduction of a technology into the market and the time it is specifically covered in model codes and standards developed in the voluntary sector. After their development, there is also a timeframe of at least a year or two until the codes and standards are adopted. Until existing model codes and standards are updated or new ones are developed and then adopted, one seeking to deploy energy storage technologies or needing to verify the safety of an installation may be challenged in trying to apply currently implemented CSRs to an energy storage system (ESS). The Energy Storage System Guide for Compliance with Safety Codes and Standards1 (CG), developed in June 2016, is intended to help address the acceptability of the design and construction of stationary ESSs, their component parts, and the siting, installation, commissioning, operations, maintenance, and repair/renovation of ESS within the built environment.

  20. Safety issues of dry fuel storage at RSWF

    Clarksean, R.L.; Zahn, T.P.

    1995-01-01

    Safety issues associated with the dry storage of EBR-II spent fuel are presented and discussed. The containers for the fuel have been designed to prevent a leak of fission gases to the environment. The storage system has four barriers for the fission gases. These barriers are the fuel cladding, an inner container, an outer container, and the liner at the RSWF. Analysis has shown that the probability of a leak to the environment is much less than 10 -6 per year, indicating that such an event is not considered credible. A drop accident, excessive thermal loads, criticality, and possible failure modes of the containers are also addressed

  1. Action taken by the french safety authorities for fire protection and fire fighting in basic nuclear plants

    Savornin, J.; Gibault, M.; Berger, R.; Kaluzny, Y.; Wallard, H.E.; Winter, D.

    1989-03-01

    The safety goal for nuclear installations is to prevent the dispersal of radioactive substances, both in the work area and outside the buildings into the environment. It is therefore at the design stage, then during construction and subsequent operation that it is necessary to take preventive measures against the outbreak of fire, and to take precautions to ensure that the consequences will always be limited. The paper describes the arrangements made by the French safety authorities to provide protection against fire in both nuclear plants and nuclear fuel cycle installations at all these stages

  2. Life cycle assessment of solar aided coal-fired power system with and without heat storage

    Zhai, Rongrong; Li, Chao; Chen, Ying; Yang, Yongping; Patchigolla, Kumar; Oakey, John E.

    2016-01-01

    Highlights: • The comprehensive performances of three kinds of different systems were compared through LCA. • The comprehensive results of all systems were evaluated by grey relation theory. • The effects of life span, coal price, and solar collector field cost, among other factors, on the results were explored. - Abstract: Pollutant emissions from coal-fired power system have been receiving increasing attention over the past few years. Integration of solar thermal energy can greatly reduce pollutant emissions from these power stations. The performances of coal-fired power system (S1), solar aided coal-fired power system with thermal storage (S2), and solar aided coal-fired power system without thermal storage (S3) with three capacities of each kind of system (i.e., nine subsystems) were analyzed over the entire life span. The pollutant emissions and primary energy consumptions (PECs) of S1, S2, and S3 were estimated using life cycle assessment (LCA). The evaluation value of global warming potential (GWP), acidification potential (AP), respiratory effects potential (REP) and PEC were obtained based on the LCA results. Furthermore, the system investments were estimated, and grey relation theory was used to evaluate the performance of the three types of systems comprehensively. Finally, in order to find the effect of some main factors on the solar aided coal-fired power system (SACFPS), uncertainty analysis has been carried out. The LCA results show that the pollutant emissions and PEC mainly take place in the fuel processing and operation stages for all three system types, and S2 performs the best among the three systems based on the grey relation analysis results. And the uncertainty analysis shows that with longer life span, the power system have better performance; with higher coal price, the power system will have worse performance; with lower solar collector field cost, the solar aided coal-fired power system will be more profitable than the base

  3. Thermal-Responsive Polymers for Enhancing Safety of Electrochemical Storage Devices.

    Yang, Hui; Leow, Wan Ru; Chen, Xiaodong

    2018-03-01

    Thermal runway constitutes the most pressing safety issue in lithium-ion batteries and supercapacitors of large-scale and high-power density due to risks of fire or explosion. However, traditional strategies for averting thermal runaway do not enable the charging-discharging rate to change according to temperature or the original performance to resume when the device is cooled to room temperature. To efficiently control thermal runaway, thermal-responsive polymers provide a feasible and reversible strategy due to their ability to sense and subsequently act according to a predetermined sequence when triggered by heat. Herein, recent research progress on the use of thermal-responsive polymers to enhance the thermal safety of electrochemical storage devices is reviewed. First, a brief discussion is provided on the methods of preventing thermal runaway in electrochemical storage devices. Subsequently, a short review is provided on the different types of thermal-responsive polymers that can efficiently avoid thermal runaway, such as phase change polymers, polymers with sol-gel transitions, and polymers with positive temperature coefficients. The results represent the important development of thermal-responsive polymers toward the prevention of thermal runaway in next-generation smart electrochemical storage devices. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Safety in transport and storage of radioactive materials

    Mezrahi, A.; Xavier, A.M.

    1987-01-01

    The increasing utilization of radioisotopes in Industrial, Medical and Research Facilities as well as the processing of Nuclear Materials involve transport activities in a routine basis. The present work has the following main objectives: I) the identification of the safety aspects related to handling, transport and storage of radioactive materials; II) the orientation of the personnel responsible for the radiological safety of Radioactive Installations viewing the elaboration and implementation of procedures to minimize accidents; III) the report of case-examples of accidents that have occured in Brazil due to non-compliance with Transport Regulations. (author) [pt

  5. Safety Test Report for the SNF Dry Storage System

    Bang, K. S.; Seo, K. S.; Lee, J. H.; Lee, J. C.; Choi, W. S

    2008-11-15

    This is technical report conducted by KAERI under the contract with NETEC for safety test for the PWR S/F dry storage system. Leak Test was performed after drop test and turn-over test, the measured leakage rate was lower than allowable leakage rate. It is revealed that the containment integrity of the dry storage system is maintained. In the seismic test, the moving of the model was measured at SRTH seismic response of 0.4 g and 0.8 g. Therefore the seismic test results can be used fully to the test data for verification of the seismic analysis. In the thermal test, the direction of the inlet and outlet of the air has no effect on the heat transfer performance. The passive heat removal system of the horizontal storage module was designed well.

  6. Safety assessment of OPG's used fuel for dry storage

    Roman, H.; Khan, A.

    2005-01-01

    'Full text:' Ontario Power Generation (OPG) operates the Pickering Waste Management Facility (PWMF) and Western Waste Management Facility (WWMF) where OPG has been storing 10-year or older used fuel in the Dry Storage Containers (DSCs) since 1996 and 2003 respectively. The construction licence for the Darlington Used Fuel Dry Storage Facility (DUFDSF) was obtained in August 2004. Safety assessment of the used fuel for dry storage is required to support each request for regulatory approval to construct and operate a dry storage facility. The objective of the safety assessment is to assess the used fuel performance under normal operation and postulated credible accident scenarios. A reference used fuel bundle is defined based on the operating history and data on fuel discharged from the reactors of the specific nuclear generating station. The characteristics of the reference used fuel bundle are used to calculate the nuclide inventory, source term and decay heat used for the assessment. When assessing malfunctions and accidents, postulated external and internal events are considered. Consideration is also given to the design basis accidents of the specific nuclear generating station that could affect the used fuel under dry storage. For those events deemed credible (i.e. probability > 10 -7 ), a bounding fuel failure consequence is predicted. Given the chemical characteristics of the radionuclides in used fuel, the design of the CANDU fuel and the conditions inside the DSC, in the event that a used fuel bundle should become damaged during used fuel dry storage operations, the only significant radionuclides species that are volatile are krypton-85 and tritium. Release of these radionuclides is considered in calculating public and worker doses. (author)

  7. Quantitative assessment of safety barrier performance in the prevention of domino scenarios triggered by fire

    Landucci, Gabriele; Argenti, Francesca; Tugnoli, Alessandro; Cozzani, Valerio

    2015-01-01

    The evolution of domino scenarios triggered by fire critically depends on the presence and the performance of safety barriers that may have the potential to prevent escalation, delaying or avoiding the heat-up of secondary targets. The aim of the present study is the quantitative assessment of safety barrier performance in preventing the escalation of fired domino scenarios. A LOPA (layer of protection analysis) based methodology, aimed at the definition and quantification of safety barrier performance in the prevention of escalation was developed. Data on the more common types of safety barriers were obtained in order to characterize the effectiveness and probability of failure on demand of relevant safety barriers. The methodology was exemplified with a case study. The results obtained define a procedure for the estimation of safety barrier performance in the prevention of fire escalation in domino scenarios. - Highlights: • We developed a methodology for the quantitative assessment of safety barriers. • We focused on safety barriers aimed at preventing domino effect triggered by fire. • We obtained data on effectiveness and availability of the safety barriers. • The methodology was exemplified with a case study of industrial interest. • The results showed the role of safety barriers in preventing fired domino escalation

  8. EFFICIENCY OF FIRE-FIGHTING PROTECTION OBJECTS IN PROVISION OF FIRE SAFETY AT INDUSTRIAL ENTERPRISES

    A. V. Zhovna

    2008-01-01

    The paper gives an analysis of economic results pertaining to organization of a system for fire-fighting protection of industrial enterprises in theRepublicofBelarus. Statistical data on operational conditions of technical means of fire-fighting protection, particularly, automatic systems for detection and extinguishing of fires, systems of internal fire-fighting water-supply.  Requirements and provisions  of normative and technical documents are thoroughly studied. Observance of these docume...

  9. Fire Safety Aspects of Polymeric Materials. Volume 2. Test Methods, Specifications and Standards

    1979-01-01

    Chairman: Dr. Seymour L. Blum Vice President Northern Energy Corporation 70 Memorial Drive Cambridge, MA 02142 Dr. George S. Ansell Dean, School...limitations, is perhaps the most firmly grounded and thoroughly docu- mented of any in the fire safety field (Benjamin and Adams , 1976). Having established...of the largest fire experiments ever undertaken. Operation Euroka, a 50 acre wildland fuel fire in Australia ( Adams et al., 1973). Scaling and

  10. Safety aspects of spent nuclear fuel interim storage installations

    Romanato, Luiz Sergio [Centro Tecnologico da Marinha em Sao Paulo (CTMSP), Sao Paulo, SP (Brazil). Dept. da Qualidade. Div. de Sistemas da Qualidade]. E-mail: romanato@ctmsp.mar.mil.br; Rzyski, Barbara Maria [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Div. de Ensino]. E-mail: bmrzyski@ipen.br

    2007-07-01

    Nowadays safety and security of spent nuclear fuel (SNF) interim storage installations are very important, due to a great concentration of fission products, actinides and activation products. In this kind of storage it is necessary to consider the physical security. Nuclear installations have become more vulnerable. New types of accidents must be considered in the design of these installations, which in the early days were not considered like: fissile material stolen, terrorists' acts and war conflicts, and traditional accidents concerning the transport of the spent fuel from the reactor to the storage location, earthquakes occurrence, airplanes crash, etc. Studies related to airplane falling had showed that a collision of big commercials airplanes at velocity of 800 km/h against SNF storage and specially designed concrete casks, do not result in serious structural injury to the casks, and not even radionuclides liberation to the environment. However, it was demonstrated that attacks with modern military ammunitions, against metallic casks, are calamitous. The casks could not support a direct impact of this ammo and the released radioactive materials can expose the workers and public as well the local environment to harmful radiation. This paper deals about the main basic aspects of a dry SNF storage installation, that must be physically well protected, getting barriers that difficult the access of unauthorized persons or vehicles, as well as, must structurally resist to incidents or accidents caused by unauthorized intrusion. (author)

  11. Safety aspects of spent nuclear fuel interim storage installations

    Romanato, Luiz Sergio

    2007-01-01

    Nowadays safety and security of spent nuclear fuel (SNF) interim storage installations are very important, due to a great concentration of fission products, actinides and activation products. In this kind of storage it is necessary to consider the physical security. Nuclear installations have become more vulnerable. New types of accidents must be considered in the design of these installations, which in the early days were not considered like: fissile material stolen, terrorists' acts and war conflicts, and traditional accidents concerning the transport of the spent fuel from the reactor to the storage location, earthquakes occurrence, airplanes crash, etc. Studies related to airplane falling had showed that a collision of big commercials airplanes at velocity of 800 km/h against SNF storage and specially designed concrete casks, do not result in serious structural injury to the casks, and not even radionuclides liberation to the environment. However, it was demonstrated that attacks with modern military ammunitions, against metallic casks, are calamitous. The casks could not support a direct impact of this ammo and the released radioactive materials can expose the workers and public as well the local environment to harmful radiation. This paper deals about the main basic aspects of a dry SNF storage installation, that must be physically well protected, getting barriers that difficult the access of unauthorized persons or vehicles, as well as, must structurally resist to incidents or accidents caused by unauthorized intrusion. (author)

  12. Fire safety requirements for electric cables and lines in deep coal mines

    Herms, C D

    1982-01-07

    In the case of a mine fire, an additional hazard from combustible cable material is likely to arise only in those few areas of the mine where special circumstances might help the fire to spread along the cables. It is more important to preserve the functional integrity of cables in the outbye roads which are affected by fire gases then at the actual seat of the fire. Mine cables with better fire-resistant properties should be made from materials which do not propagate fires, do not release burning drops, develop the lowest possible fume density and/or will permanently resist gas temperatures of 200 to 300/sup 0/C. Fire test specifications should be defined for such special cables, based on corresponding draft VDE directives. In proposing these measures the proviso is made then improvement in safety can be clearly demonstrated.

  13. Probabilistic safety analysis for fire events for the NPP Isar 2

    Schmaltz, H.; Hristodulidis, A.

    2007-01-01

    The 'Probabilistic Safety Analysis for Fire Events' (Fire-PSA KKI2) for the NPP Isar 2 was performed in addition to the PSA for full power operation and considers all possible events which can be initiated due to a fire. The aim of the plant specific Fire-PSA was to perform a quantitative assessment of fire events during full power operation, which is state of the art. Based on simplistic assumptions referring to the fire induced failures, the influence of system- and component-failures on the frequency of the core damage states was analysed. The Fire-PSA considers events, which will result due to fire-induced failures of equipment on the one hand in a SCRAM and on the other hand in events, which will not have direct operational effects but because of the fire-induced failure of safety related installations the plant will be shut down as a precautionary measure. These events are considered because they may have a not negligible influence on the frequency of core damage states in case of failures during the plant shut down because of the reduced redundancy of safety related systems. (orig.)

  14. Criticality safety evaluation for long term storage of FFTF fuel in interim storage casks

    Richard, R.F.

    1995-01-01

    It has been postulated that a degradation phenomenon, referred to as ''hot cell rot'', may affect irradiated FFTF mixed plutonium-uranium oxide (MOX) fuel during dry interim storage. ''Hot cell rot'' refers to a variety of phenomena that degrade fuel pin cladding during exposure to air and inert gas environments. It is thought to be a form of caustic stress corrosion cracking or environmentally assisted cracking. Here, a criticality safety analysis was performed to address the effect of the ''hot cell rot'' phenomenon on the long term storage of irradiated FFTF fuel in core component containers. The results show that seven FFTF fuel assemblies or six Ident-69 pin containers stored in core component containers within interim storage casks will remain safely subcritical

  15. Post-fire management regimes affect carbon sequestration and storage in a Sierra Nevada mixed conifer forest

    Elizabeth M. Powers; John D. Marshall; Jianwei Zhang; Liang Wei

    2013-01-01

    Forests mitigate climate change by sequestering CO2 from the atmosphere and accumulating it in biomass storage pools. However, in dry conifer forests, fire occasionally returns large quantities of CO2 to the atmosphere. Both the total amount of carbon stored and its susceptibility to loss may be altered by post-fire land...

  16. Fire probability safety analysis in France for 900 MWe nuclear power plants

    Bertrand, R.; Bonneval, F.; Mattei, J.M.

    2000-01-01

    This paper describes the methodology implemented by the Institute for Nuclear Safety and Protection (IPSN) to carry out the Fire Probabilistic Safety Assessment (Fire PSA) for French 900 MWe pressurised water reactors. The initial results obtained are presented. Additional research and development activities are indicated which IPSN carried out or decided to perform in order to reduce the amount of uncertainty associated with the data or to confirm hypotheses that can impact significantly the study results. (orig.) [de

  17. Fire protection considerations in the design of plutonium handling and storage facility

    Blanchard, A.

    2000-01-01

    Unwanted fire in a facility that handles plutonium must be addressed early in the facility design. Such fires have the potential for transporting radioactive contamination throughout the building and widespread downwind dispersal. Features that mitigate such events can be severely challenged during the fire. High temperatures can cause storage containers to burst; a very efficient dispersal mechanism for radioactive contamination. The fire will also establish ventilation patterns that cause the migration of smoke and radioactive contamination throughout the facility. The smoke and soot generated by the fire will enter the exhaust system and travel to the filtration system where it will deposit on the filters. The quantity of smoke generated during a typical multi-room fire is expected to blind most High Efficiency Particulate Airfilter (HEPA) media. The blinding can have two possible outcomes. (1) The air movement though the facility is reduced, compromising the negative pressure containment and allowing contamination to leave the building though doors and other openings; or (2) the filters collapse allowing the contamination to bypass the filtration media and exit the building through the filter plenum. HEPA filter blinding during severe fires can be prevented or mitigated. Increasing the face surface area of HEPA filters will increase the smoke filtration capacity of the system, thus preventing blinding. As an alternative sandfilters can be provided to mitigate the effects of the HEPA filter bypass. Both concepts have distinct advantages. This paper will explore these two design concepts and two others; it will describe the design requirements necessary for each concept to prevent unacceptable contamination spread. The intent is to allow the filter media selection to be based on a comprehensive understanding of the four different design concepts

  18. Presentation of a Software Method for Use of Risk Assessment in Building Fire Safety Measure Optimization

    A. R. Koohpaei

    2012-05-01

    Full Text Available Background and aims: The property loss and physical injuries due to fire events in buildings demonstrate the necessity of implementation of efficient and performance based fire safety measures. Effective and high efficiency protection is possible when design and selection of protection measures are based on risk assessment. This study aims at presenting a software method to make possible selection and design of building fire safety measures based upon quantitative risk assessment and building characteristics. Methods: based on “Fire Risk Assessment Method for Engineer (FRAME” a program in MATLB software was written. The first section of this program, according to the FRAME method and based on the specification of a building, calculates the potential risk and acceptable risk level. In the second section, according to potential risk, acceptable risk level and the fire risk level that user want, program calculate concession of protective factor for that building.Results: The prepared software make it possible to assign the fire safety measure based on quantitative risk level and all building specifications. All calculations were performed with 0.001 of precision and the accuracy of this software was assessed with handmade calculations. During the use of the software if an error occurs in calculations, it can be distinguished in the output. Conclusion: Application of quantitative risk assessment is a suitable tool for increasing of efficiency in designing and execution of fire protection measure in building. With using this software the selected fire safety measure would be more efficient and suitable since the selection of fire safety measures performed on risk assessment and particular specification of a building. Moreover fire risk in the building can be managed easily and carefully.

  19. Parents' Depressive Symptoms and Gun, Fire, and Motor Vehicle Safety Practices.

    Morrissey, Taryn W

    2016-04-01

    This study examined associations between mothers' and fathers' depressive symptoms and their parenting practices relating to gun, fire, and motor vehicle safety. Using data from the Early Childhood Longitudinal Study-Birth Cohort (ECLS-B), a nationally representative sample of children birth to age five, linear probability models were used to examine associations between measures of parents' depressive symptoms and their use of firearms, smoke detectors, and motor vehicle restraints. Parents reported use of smoke detectors, motor vehicle restraints, and firearm ownership and storage. Results suggest mothers with moderate or severe depressive symptoms were 2 % points less likely to report that their child always sat in the back seat of the car, and 3 % points less likely to have at least one working smoke detector in the home. Fathers' depressive symptoms were associated with a lower likelihood of both owning a gun and of it being stored locked. Fathers' depressive symptoms amplified associations between mothers' depressive symptoms and owning a gun, such that having both parents exhibit depressive symptoms was associated with an increased likelihood of gun ownership of between 2 and 6 % points. Interventions that identify and treat parental depression early may be effective in promoting appropriate safety behaviors among families with young children.

  20. Establishing Fire Safety Skills Using Behavioral Skills Training

    Houvouras, Andrew J., IV; Harvey, Mark T.

    2014-01-01

    The use of behavioral skills training (BST) to educate 3 adolescent boys on the risks of lighters and fire setting was evaluated using in situ assessment in a school setting. Two participants had a history of fire setting. After training, all participants adhered to established rules: (a) avoid a deactivated lighter, (b) leave the training area,…

  1. Safety implications associated with in-plant pressurized gas storage and distribution systems

    Guymon, R.H.

    1986-01-01

    Storage and handling of compressed gases at nuclear power plants were studied to identify any potential safety hazards. Gases investigated were air, acetylene, carbon dioxide, chlorine, Halon, hydrogen, nitrogen, oxygen, propane, and sulfur hexafluoride. Physical properties of gases were reviewed, as were applicable industrial codes and standards. Incidents involving pressurized gases in general industry and in the nuclear industry were studied. In this report general hazards, such as missiles from ruptures, rocketing of cylinders, fires, explosions, asphyxiation, and toxicity, are discussed. Even though some serious injuries and deaths have occurred over the years in industries handling and using pressurized gases, the industrial codes, standards, practices, and procedures are very comprehensive. The most important step one can take to ensure the safe handling of gases is to enforce these well-known and established methods

  2. Criticality safety of low-density storage arrays

    Bauer, T. H.; Nuclear Engineering Division

    2005-01-01

    This paper proposes a straightforward bounding method for the criticality safety analysis of fissionable materials configured into large arrays of standard containers. While criticality-safe storage limits have been well established for single containers, even under flooded conditions, it is also necessary to rule out any potential for criticality arising from neutronic interactions among multiple containers that might build up over long distances in a large array. Traditionally, the array problem has been approached by individual Monte Carlo analyses of explicit arrangements of single units and their surroundings. Deemphasizing specific configurations, the present technique takes advantage of low average density of fissionable material in typical storage arrays to separate neutron interactions that take place in the neutron's 'birth unit' from subsequent interactions in a dilute array. Numerous explicit Monte Carlo analyses show that array effects may be conservatively calculated by analyses that homogenize fissionable contents and depend only on the overall array shape, size, and reflective boundary

  3. Criticality safety of low-density storage arrays

    Bauer, T.H.

    1996-01-01

    This paper proposes a straightforward bounding method for the criticality safety analysis of fissionable materials configured into large arrays of standard containers. While criticality-safe storage limits have been well established for single containers, even under flooded conditions, it is also necessary to rule out any potential for criticality arising from neutronic interactions among multiple containers that might build up over long distances in a large array. Traditionally, the array problem has been approached by individual Monte Carlo analyses of explicit arrangements of single units and their surroundings. Deemphasizing specific configurations, the present technique takes advantage of low average density of fissionable material in typical storage arrays to separate neutron interactions that take place in the neutron's open-quotes birth unitclose quotes from subsequent interactions in a dilute array. Numerous explicit Monte Carlo analyses show that array effects may be conservatively calculated by analyses that homogenize fissionable contents and depend only on the overall array shape, size, and reflective boundary

  4. A study on fire design accidental loads for aluminum safety helidecks

    Sang Jin Kim

    2016-11-01

    Full Text Available The helideck structure must satisfy the safety requirements associated with various environmental and accidental loads. Especially, there have been a number of fire accidents offshore due to helicopter collision (take-off and/or landing in recent decades. To prevent further accidents, a substantial amount of effort has been directed toward the management of fire in the safety design of offshore helidecks. The aims of this study are to introduce and apply a procedure for quantitative risk assessment and management of fires by defining the fire loads with an applied example. The frequency of helicopter accidents are considered, and design accidental levels are applied. The proposed procedures for determining design fire loads can be efficiently applied in offshore helideck development projects.

  5. Spacecraft Fire Safety Research at NASA Glenn Research Center

    Meyer, Marit

    2016-01-01

    Appropriate design of fire detection systems requires knowledge of both the expected fire signature and the background aerosol levels. Terrestrial fire detection systems have been developed based on extensive study of terrestrial fires. Unfortunately there is no corresponding data set for spacecraft fires and consequently the fire detectors in current spacecraft were developed based upon terrestrial designs. In low gravity, buoyant flow is negligible which causes particles to concentrate at the smoke source, increasing their residence time, and increasing the transport time to smoke detectors. Microgravity fires have significantly different structure than those in 1-g which can change the formation history of the smoke particles. Finally the materials used in spacecraft are different from typical terrestrial environments where smoke properties have been evaluated. It is critically important to detect a fire in its early phase before a flame is established, given the fixed volume of air on any spacecraft. Consequently, the primary target for spacecraft fire detection is pyrolysis products rather than soot. Experimental investigations have been performed at three different NASA facilities which characterize smoke aerosols from overheating common spacecraft materials. The earliest effort consists of aerosol measurements in low gravity, called the Smoke Aerosol Measurement Experiment (SAME), and subsequent ground-based testing of SAME smoke in 55-gallon drums with an aerosol reference instrument. Another set of experiments were performed at NASAs Johnson Space Center White Sands Test Facility (WSTF), with additional fuels and an alternate smoke production method. Measurements of these smoke products include mass and number concentration, and a thermal precipitator was designed for this investigation to capture particles for microscopic analysis. The final experiments presented are from NASAs Gases and Aerosols from Smoldering Polymers (GASP) Laboratory, with selected

  6. Assessment of the overall fire safety arrangements at nuclear power plants

    1996-01-01

    The present publication has been developed with the help of experts from regulatory, operating and engineering organizations, all with practical experience in the field of fire safety of nuclear power plants. The publication comprises a detailed checklist of the specific elements to be addressed when assessing the adequacy and effectiveness of the overall fire safety arrangements of operating nuclear power plants. The publication will be useful not only to regulators and safety assessors but also to operators and designers. The book addresses a specialized topic outlined in Safety Guide No. 50-SG-D2 (Rev.1), Fire Protection in Nuclear Power Plants, and it is recommended that it be used in conjunction with this Safety Series publication

  7. An Assessment of the Fire Safety Hazard Associated with External Fire Spread in Tall Buildings with Combustible Façade Material

    Lavard Brogaard, Nicholas; Torero, Jose L.; Jomaas, Grunde

    2014-01-01

    in order to obtain a conclusive assessment of the fire safety hazards associated with combustible facades. Prescriptive fire safety codes are typically not allowing any type of combustible façade in buildings that are taller than 2-3 stories. However, a performance based approach does not contain height...

  8. Evaluation of the Cable Types for Safety Requirements during Fire Conditions in Nuclear Facility

    Al-kattan, W.A.

    2015-01-01

    In Nuclear Power Plants (NPPs), the fire in cables causes many dangerous events in electrical or mechanical operations causing a nuclear reactor melt down. Main Control Room (MCR) in nuclear power plants have therefore, special concern in the fire protection systems. The Nuclear International Atomic Energy Agency (IAEA) has promoted the use of risk-informed and performance based methods for fire protection. These methods affirm the relevant needs to develop realistic methods to quantify the risk of fire to NPPs safety. The recent electrical cable testing has been carried out to provide empirical data on the failure modes and likelihood of fire-induced damage. In this thesis, will use fire modeling to develop fire probabilistic safety assessment to estimate the likelihood of fire induced cable damage given a specified fire profile. The objective of this work is to provide a comprehensive evaluation of the most recent fire-induced circuit failure due to different cables type that used inside the NPPs by simulation using fire modeling. One of this work scope is to suggest a suitable cable insulation material especially in case of the thermal failure thresholds, for developing the electrical cable thermal fragility distributions and evaluate parameters that influence fire-induced circuit failure modes. The main control room is implementing using the CFAST (fire simulation package). The simulation results represent the full development fire temperature and heat flux as well as the output gases. The results can be used as the basic parameters of the cables comparison and then evaluation.The importance of these results are not only for evaluating the cables but one can efficiently use them to improve the whole NPPs safety levels. The gases results of the fire simulation inside the room are oxygen, carbon monoxide, carbon dioxide, and hydrogen chloride. These gases are being used lot achieving the healthy protection of NPPs. Finally, one can measure the healthy environment

  9. Evaluation of Generic Issue 57: Effects of fire protection system actuation on safety-related equipment

    Lambright, J.; Bohn, M.; Lynch, J.; Ross, S.; Brosseau, D.

    1992-12-01

    Nuclear power plants have experienced actuations of fire protection systems (FPSs) under conditions for which these systems were not intended to actuate and also have experienced advertent actuations with the presence of a fire. These actuations have often damaged safety-related equipment. A review of the impact of past occurrences of both types of such events and their impact on plant safety systems, an analysis of the risk impacts of such events on nuclear power plant safety, and a cost-benefit analysis of potential corrective measures have been performed. Thirteen different scenarios leading to actuation of fire protection systems due to a variety of causes were identified. These scenarios ranged from inadvertent actuation caused by human error to hardware failure, and include seismic root causes and seismic/fire interactions. A quantification of these thirteen root causes, where applicable, was performed on generically applicable scenarios. This document, Volume 4, contains appendices E and F of this report

  10. Bridging the divide between fire safety research and fighting fire safely: How do we convey research innovation to contribute more effectively to wildland firefighter safety?

    Theodore Ted Adams; Bret W. Butler; Sara Brown; Vita Wright; Anne Black

    2017-01-01

    Creating a safe workplace for wildland firefighters has long been at the centre of discussion for researchers and practitioners. The goal of wildland fire safety research has been to protect operational firefighters, yet its contributions often fall short of potential because much is getting lost in the translation of peer-reviewed results to potential and intended...

  11. Proposal of safety design methodologies for an HTGR-hydrogen production system. Mainly on countermeasures against fire and explosion

    Nishihara, Tetsuo; Hada, Kazuhiko; Shiozawa, Syusaku

    1996-03-01

    Among key issues of the safety design for an HTGR-hydrogen production system is to ensure the safety of the nuclear reactor against fire and explosion accidents in the hydrogen production plant. The fire and explosion accidents in the hydrogen production plant are categorized into the following two cases; Accidents inside the reactor building (R/B) and accidents outside the R/B. Against accidents inside the R/B, the proposed safety design concept is to prevent the occurrence of the accidents based on the defence in depth concept. The piping system and/or heat transfer tubes which have the potential possibility of combustible materials ingress into the R/B due to the failure are designed at the highest aseismic level to prevent the failure against severe earthquake. Even if the failure occurs, the piping trench and related compartments are fulfilled with nitrogen so as to prevent the occurrence of accidents. The proposed safety design concept for the accidents outside the R/B is the mitigation of effects of accidents. Proposed countermeasures is to take the safe distance between the hydrogen production plant and the items important to safety in the nuclear plant. We showed that the anticipated accidents to estimate the safe distance are large scale pool burning, fireball, pressure vessel burst and vapor cloud explosion. Especially, new estimating concept to establish the safe distance is proposed for the vapor cloud explosion. To reduce the safe distance, we proposed the underground non-pressurized storage tank and ventilation system for the storage of large amount of combustible liquid. (author). 61 refs

  12. Criticality safety considerations. Integral Monitored Retrievable Storage (MRS) Facility

    1986-09-01

    This report summarizes the criticality analysis performed to address criticality safety concerns and to support facility design during the conceptual design phase of the Monitored Retrievable Storage (MRS) Facility. The report addresses the criticality safety concerns, the design features of the facility relative to criticality, and the results of the analysis of both normal operating and hypothetical off-normal conditions. Key references are provided (Appendix C) if additional information is desired by the reader. The MRS Facility design was developed and the related analysis was performed in accordance with the MRS Facility Functional Design Criteria and the Basis for Design. The detailed description and calculations are documented in the Integral MRS Facility Conceptual Design Report. In addition to the summary portion of this report, explanatary notes for various terms, calculation methodology, and design parameters are presented in Appendix A. Appendix B provides a brief glossary of technical terms

  13. Effect of Storage on the Quality and Safety of Grains in Tharaka ...

    The contribution of grains to food security is limited by deterioration during storage and as such it was necessary to document the effect of storage on their quality and safety. The objective of this study was to determine the effect of storage on the quality and safety of grains in Maragua and Gikingo locations, Tharaka District, ...

  14. The Safety Assessment of Long term Interim Storage at Sellafield

    Buchan, Andrew B.

    2014-01-01

    The Sellafield site comprises a wide range of nuclear facilities, including operating facilities associated with the Magnox reprocessing programme, the Thermal Oxide Reprocessing Plant (THORP) and a range of waste treatment plants. The operational life of some of the site facilities currently extends to 2120, requiring the retrieval, treatment, consolidation and safe extended storage of a variety of radioactive materials. Sellafield has utilised its existing safety assessment processes to inform and prioritise studies into beyond design basis events and resilience evaluation required following Fukushima by UK regulators and industry bodies such as WANO. There are significant differences between NPPs, for which the ENSREG 'stress tests' were originally intended, and the Sellafield site which is instead centered around two reprocessing facilities (Magnox and THORP), with a supporting infrastructure of waste processing and storage facilities, coupled with a legacy of high hazard older facilities. In the former case the consequences of a catastrophic failure are promptly realised, leading to significant problems such as fuel failure / meltdown in AGRs and LWRs respectively in the event of complete loss of cooling. At Sellafield, the processes are carried out at comparatively low temperatures and pressures with relatively low rates of change following any loss of cooling. Instead the consequences of catastrophic failure at Sellafield are more directly related to the very large inventories of radioactive materials, including high level liquid wastes and unprocessed fuels, present in specific plants and to the condition of the ageing assets, holding legacy wastes. The paper will consider how a number of analysis techniques have been used to establish a safety case for fault and accident conditions, i.e. design basis analysis (DBA), probabilistic safety analysis (PSA) and severe accident analysis (SAA) DBA is focused on the key safety measures for those initiating faults

  15. 48 CFR 2052.235-71 - Safety, health, and fire protection.

    2010-10-01

    ... extension of time or for compensation or damages by reason of, or in connection with, this type of work... performance of the work under this contract to protect the health and safety of its employees and of members... hazards to life and property. The contractor shall comply with all applicable health, safety, and fire...

  16. Protection against internal fires and explosions in the design of nuclear power plants. Safety guide

    2004-01-01

    Experience of the past two decades in the operation of nuclear power plants and modern analysis techniques confirm that fire may be a real threat to nuclear safety and should receive adequate attention from the beginning of the design process throughout the life of the plant. Within the framework of the NUSS programme, a Safety Guide on fire protection had therefore been developed to enlarge on the general requirements given in the Code. Since its first publication in 1979, there has been considerable development in protection technology and analysis methods and after the Chernobyl accident it was decided to revise the existing Guide. This Safety Guide supplements the requirements established in Safety of Nuclear Power Plants: Design. It supersedes Safety Series No. 50-SG-D2 (Rev. 1), Fire Protection in Nuclear Power Plants: A Safety Guide, issued in 1992.The present Safety Guide is intended to advise designers, safety assessors and regulators on the concept of fire protection in the design of nuclear power plants and on recommended ways of implementing the concept in some detail in practice

  17. A safety study on the wet storage of spent fuel

    Chun, Kwan Sik; Whang, Joo Ho; Lee, Hoo Kun; Choi, Jong Won; Lee, Jong Geun

    1989-02-01

    This study is to provide data related with a basic design of the spent fuel storage facility in the field of radiation and to establish the safety assessment methodology of away from reactor spent fuel storage facility. This is in progress and continue upto the year of 1991. The mathematical model which predict the quantity of environmental release of fission and corrosion products from spent fuel received and stored in wet storage facility operated in normal conditions was prepared. The decay characteristic of domestic spent fuels are analysed and then the coefficients for the prediction of the decay heat by simple formular was determined. This correlations could predict decay heat of spent fuel with ±10% difference from ORIGEN2 results. The release factor of cobalt out of PWR spent fuel in PIE pool is 7.97 x 10-12∼8.49 x 10-11 Ci/ sec-rod, which appears to be linear without being connected with the types of fuel defects, but that of cesium varies with the defect type and the exposure time in water. In water condition, release factor of uranium out of CANDU fuel pellets appears to be about 5 x 10-8/day, whose tendency is similar to that of cesium of the latter half of the exposure time of water. (Author)

  18. Construction products performances and basic requirements for fire safety of facades in energy rehabilitation of buildings

    Laban Mirjana Đ.

    2015-01-01

    Full Text Available Construction product means any product or kit which is produced and placed on the market for incorporation in a permanent manner in construction works, or parts thereof, and the performance of which has an effect on the performance of the construction works with respect to the basic requirements for construction works. Safety in case of fire and Energy economy and heat retention represent two among seven basic requirements which building has to meet according to contemporary technical rules on planning and construction. Performances of external walls building materials (particularly reaction to fire could significantly affect to fire spread on the façade and other building parts. Therefore, façade shaping and materialization in building renewal process, has to meet the fire safety requirement, as well as the energy requirement. Brief survey of fire protection regulations development in Serbia is presented in the paper. Preventive measures for fire risk reduction in building façade energy renewal are proposed according to contemporary fire safety requirements.

  19. Evaluation of safety margin of packaging for radioactive materials transport during a severe fire

    Gilles, P.; Ringot, C.; Warniez, P.; Grall, L.; Perrot, J.

    1986-06-01

    A high safety is obtained by International regulations on radioactive materials transport. It is obtained by packaging design adapted to the potential risk. An important accident to consider is fire for two reasons: the probability of fire occuring for time and temperature higher than conditions applied to type B packaging (800 deg C, 1/2 hr) is not negligible, particularly for air or maritime transport. Safety margins are studied by computation and experimental tests. This report presents results obtained for different types of packagings. Results show a large safety margin [fr

  20. Techno-economic analysis of oxy-combustion coal-fired power plant with cryogenic oxygen storage

    Hanak, Dawid Piotr; Manovic, Vasilije

    2017-01-01

    Around 43% of the cumulative CO2 emissions from the power sector between 2012 and 2050 could be mitigated through implementation of carbon capture and storage, and utilisation of renewable energy sources. Energy storage technologies can increase the efficiency of energy utilisation and thus should be widely deployed along with low-emission technologies. This study evaluates the techno-economic performance of cryogenic O2 storage implemented in an oxy-combustion coal-fired power plant as a mea...

  1. Safety Aspects of Sustainable Storage Dams and Earthquake Safety of Existing Dams

    Martin Wieland

    2016-09-01

    Full Text Available The basic element in any sustainable dam project is safety, which includes the following safety elements: ① structural safety, ② dam safety monitoring, ③ operational safety and maintenance, and ④ emergency planning. Long-term safety primarily includes the analysis of all hazards affecting the project; that is, hazards from the natural environment, hazards from the man-made environment, and project-specific and site-specific hazards. The special features of the seismic safety of dams are discussed. Large dams were the first structures to be systematically designed against earthquakes, starting in the 1930s. However, the seismic safety of older dams is unknown, as most were designed using seismic design criteria and methods of dynamic analysis that are considered obsolete today. Therefore, we need to reevaluate the seismic safety of existing dams based on current state-of-the-art practices and rehabilitate deficient dams. For large dams, a site-specific seismic hazard analysis is usually recommended. Today, large dams and the safety-relevant elements used for controlling the reservoir after a strong earthquake must be able to withstand the ground motions of a safety evaluation earthquake. The ground motion parameters can be determined either by a probabilistic or a deterministic seismic hazard analysis. During strong earthquakes, inelastic deformations may occur in a dam; therefore, the seismic analysis has to be carried out in the time domain. Furthermore, earthquakes create multiple seismic hazards for dams such as ground shaking, fault movements, mass movements, and others. The ground motions needed by the dam engineer are not real earthquake ground motions but models of the ground motion, which allow the safe design of dams. It must also be kept in mind that dam safety evaluations must be carried out several times during the long life of large storage dams. These features are discussed in this paper.

  2. Fire Safety Tests for Spherical Resorcinol Formaldehyde Resin: Data Summary Report

    Kim, Dong-Sang; Peterson, Reid A.; Schweiger, Michael J.

    2012-07-30

    A draft safety evaluation of the scenario for spherical resorcinol-formaldehyde (SRF) resin fire inside the ion exchange column was performed by the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Fire Safety organization. The result of this draft evaluation suggested a potential change of the fire safety classification for the Cesium Ion Exchange Process System (CXP) emergency elution vessels, equipment, and piping, which may be overly bounding based on the fire performance data from the manufacturer of the ion exchange resin selected for use at the WTP. To resolve this question, the fire properties of the SRF resin were measured by Southwest Research Institute (SwRI), following the American Society for Testing and Materials (ASTM) standard procedures, through a subcontract managed by Pacific Northwest National Laboratory (PNNL). For some tests, the ASTM standard procedures were not entirely appropriate or practical for the SRF resin material, so the procedures were modified and deviations from the ASTM standard procedures were noted. This report summarizes the results of fire safety tests performed and reported by SwRI. The efforts by PNNL were limited to summarizing the test results provided by SwRI into one consolidated data report. All as-received SwRI reports are attached to this report in the Appendix. Where applicable, the precision and bias of each test method, as given by each ASTM standard procedure, are included and compared with the SwRI test results of the SRF resin.

  3. An effective and practical fire-protection system. [for aircraft fuel storage and transport

    Mansfield, J. A.; Riccitiello, S. R.; Fewell, L. L.

    1975-01-01

    A high-performance sandwich-type fire protection system comprising a steel outer sheath and insulation combined in various configurations is described. An inherent advantage of the sheath system over coatings is that it eliminates problems of weatherability, materials strength, adhesion, and chemical attack. An experimental comparison between the protection performance of state-of-the-art coatings and the sheath system is presented, with emphasis on the protection of certain types of steel tanks for fuel storage and transport. Sheath systems are thought to be more expensive than coatings in initial implementation, although they are less expensive per year for sufficiently long applications.

  4. Evaluation of Fire Hazard and Safety Management of Heritage Buildings in Georgetown, Penang

    Othuman Mydin M.A.

    2014-03-01

    Full Text Available Fire is a subject that is always neglected and ignored as far as heritage buildings are concerned. Unlike newly-built buildings, which are required under UBBL to undergo certain fire protection system tests, people are less likely to carry out such tests and detailed assessments for heritage buildings. Thus, this research is significant as it is aimed at accomplishing several objectives including studying the current fire emergency plan, besides identifying and assessing the possible fire hazards in heritage buildings in Penang. Several case studies were carried out at a few premises such as the Khoo Kongsi, Cheah Kongsi, Hock Teik Chen Shin Temple and the Teochew Temple with the aid of the Fire Rescue Department Malaysia (FRDM. The results obtained from this study will be discussed according to several aspects focusing on general health and safety management at the site, the fire-fighting system, fire exit routes and signage at the temples, fire hazards, and fire detection and alarm.

  5. Application of fire and evacuation models in evaluation of fire safety in railway tunnels

    Cábová, Kamila; Apeltauer, Tomáš; Okřinová, Petra; Wald, František

    2017-09-01

    The paper describes an application of numerical simulation of fire dynamics and evacuation of people in a tunnel. The software tool Fire Dynamics Simulator is used to simulate temperature resolution and development of smoke in a railway tunnel. Comparing to temperature curves which are usually used in the design stage results of the model show that the numerical model gives lower temperature of hot smoke layer. Outputs of the numerical simulation of fire also enable to improve models of evacuation of people during fires in tunnels. In the presented study the calculated high of smoke layer in the tunnel is in 10 min after the fire ignition lower than the level of 2.2 m which is considered as the maximal limit for safe evacuation. Simulation of the evacuation process in bigger scale together with fire dynamics can provide very valuable information about important security conditions like Available Safe Evacuation Time (ASET) vs Required Safe Evacuation Time (RSET). On given example in software EXODUS the paper summarizes selected results of evacuation model which should be in mind of a designer when preparing an evacuation plan.

  6. Safety

    1998-01-01

    A brief account of activities carried out by the Nuclear power plants Jaslovske Bohunice in 1997 is presented. These activities are reported under the headings: (1) Nuclear safety; (2) Industrial and health safety; (3) Radiation safety; and Fire protection

  7. Work Health & Safety legislation; the fire engineer’s neglected duty?

    P.A. (Tony) Enright

    2014-01-01

    Fire engineers are in general, aware of their duties under Building legislation. However, they are often unfamiliar of separate duties under Work Health and Safety legislation. This paper describes an Australian case-study, but one that is presented generally so as to have applicability in those other jurisdictions where similar Work Health and Safety obligations exist. As society becomes safer, Work Health and Safety has evolved from being solely about the employer–employee relationshi...

  8. Safety during sea transport of radioactive materials. Probabilistic safety analysis of package fro sea surface fire accident

    Matsuoka, Takeshi; Obara, Isonori; Akutsu, Yukio; Aritomi, Masanori

    2000-01-01

    The ships carrying irradiated nuclear fuel, plutonium and high level radioactive wastes(INF materials) are designed to keep integrity of packaging based on the various safety and fireproof measures, even if the ship encounters a maritime fire accident. However, granted that the frequency is very low, realistic severe accidents should be evaluated. In this paper, probabilistic safety assessment method is applied to evaluate safety margin for severe sea fire accidents using event tree analysis. Based on our separate studies, the severest scenario was estimated as follows; an INF transport ship collides with oil tanker and induces a sea surface fire. Probability data such as ship's collision, oil leakage, ignition, escape from fire region, operations of cask cooling system and water flooding systems were also introduced from above mentioned studies. The results indicate that the probability of which packages cannot keep their integrity during the sea surface fire accident is very low and sea transport of INF materials is carried out very safely. (author)

  9. Utilization of the safety functional analysis techniques to optimize the separation requirements in case of fire

    Alvarez, L.M.

    1983-01-01

    The present philosophy for the fire protection of the safe shutdown capability in nuclear power plants is based on the separation of the safety-related systems in different fire areas in such a way that the redundant systems are not subject to damage from a single fire risk. The purpose ofthis paper is to show the experience gained in the application of a symmetric method of analysis to minimize the number of fire barriers being compatible with the regulatory requirements and with capability of achieving and maintaining the safe plant shutdown in the event of a fire. As a conclusion of the analysis, the separation criteria for the divisions involved in the safe plant shutdown are obtained

  10. Forum for fire protection and safety in power plants[Norway

    NONE

    2005-07-01

    The conference contains 16 presentations on topics in the fields of fire protection and safety in plants in Western Norway, reorganization and reconstruction of power systems and plants in Norway, various aspects of risk and vulnerability analysis, technological aspects of plant management and construction and problems and risks with particularly transformers. Some views on challenges of the fire departments and the new Norwegian regulations for electrical power supply systems are included. One presentation deals with challenges for Icelandic power production plants.

  11. Sodium fire studies in France. Safety experiments applied to fast reactors

    Fruchard, Y.; Colome, J.; Malet, J.C.; Berlin, M.; Duverger de Cuy, G.; Justin, J.; Duco, J.

    1976-01-01

    In fast reactors, the risk of sodium fires must be analyzed in detail and the consequences of an accidental fire must be known precisely. Beyond the search for prevention and detection means, techniques must be developed to set up a limit to damages created by an accidental fire: extinguishing, aerosol confinement, protection of the reactor structures. The program developed by the Nuclear Safety Department of the Commissariat a l'Energie Atomique to solve these various problems is described. The main results and their applications to the Super-Phenix reactor are presented [fr

  12. Sodium fire studies in France safety tests and applications on an LMFBR

    Fruchard, Y.; Colome, J.; Malet, J.C.; Berlin, M.; de Cuy, G.D.; Justin, J.; Duco, J.; Fourest, B.

    1976-01-01

    The risk of sodium fires in an LMFBR requires thorough analysis, and the possible consequences of an accidental fire must be accurately determined. Not only must means of prevention and detection be perfected, but techniques must be developed to limit the damage caused by a fire: extinguishment, aerosol containment, protection of reactor structures. The program currently undertaken by the CEA's Nuclear Safety Department covering these problems is described. The major results obtained as well as their application to the SUPER-PHENIX reactor are included

  13. Investigation of potential fire-related damage to safety-related equipment in nuclear power plants

    Wanless, J.

    1985-11-01

    Based on a review of vendor information, fire damage reports, equipment qualification and hydrogen burn test results, and material properties, thirty-three types of equipment found in nuclear power plants were ranked in terms of their potential sensitivity to fire environments. The ranking considered both the functional requirements and damage proneness of each component. A further review of the seven top-ranked components was performed, considering the relative prevalence and potential safety significance of each. From this, relays and hand switches dominate as first choices for fire damage testing with logic equipment, power supplies, transmitters, and motor control centers as future candidates

  14. Reported fire safety and first-aid amenities in Airbnb venues in 16 American cities.

    Kennedy, Hudson R; Jones, Vanya C; Gielen, Andrea

    2018-05-07

    Airbnb helps hosts rent all or part of their home to guests as an alternative to traditional hospitality settings. Airbnb venues are not uniformly regulated across the USA. This study quantified the reported prevalence of fire safety and first-aid amenities in Airbnb venues in the USA. The sample includes 120 691 venues in 16 US cities. Proportions of host-reported smoke and carbon monoxide (CO) detectors, fire extinguishers and first-aid kits were calculated. The proportion of venues that reportedly contained amenities are as follows: smoke detectors 80% (n=96 087), CO detectors 57.5% (n=69 346), fire extinguishers 42% (n=50 884) and first-aid kits 36% (n=43 497). Among this sample of Airbnb venues, safety deficiencies were noted. While most venues had smoke alarms, approximately 1/2 had CO alarms and less than 1/2 reported having a fire extinguishers or first-aid kits. Local and state governments or Airbnb must implement regulations compliant with current National Fire Protection Association fire safety standards. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Large-Scale Spacecraft Fire Safety Experiments in ISS Resupply Vehicles

    Ruff, Gary A.; Urban, David

    2013-01-01

    Our understanding of the fire safety risk in manned spacecraft has been limited by the small scale of the testing we have been able to conduct in low-gravity. Fire growth and spread cannot be expected to scale linearly with sample size so we cannot make accurate predictions of the behavior of realistic scale fires in spacecraft based on the limited low-g testing to date. As a result, spacecraft fire safety protocols are necessarily very conservative and costly. Future crewed missions are expected to be longer in duration than previous exploration missions outside of low-earth orbit and accordingly, more complex in terms of operations, logistics, and safety. This will increase the challenge of ensuring a fire-safe environment for the crew throughout the mission. Based on our fundamental uncertainty of the behavior of fires in low-gravity, the need for realistic scale testing at reduced gravity has been demonstrated. To address this concern, a spacecraft fire safety research project is underway to reduce the uncertainty and risk in the design of spacecraft fire safety systems by testing at nearly full scale in low-gravity. This project is supported by the NASA Advanced Exploration Systems Program Office in the Human Exploration and Operations Mission Directorate. The activity of this project is supported by an international topical team of fire experts from other space agencies to maximize the utility of the data and to ensure the widest possible scrutiny of the concept. The large-scale space flight experiment will be conducted on three missions; each in an Orbital Sciences Corporation Cygnus vehicle after it has deberthed from the ISS. Although the experiment will need to meet rigorous safety requirements to ensure the carrier vehicle does not sustain damage, the absence of a crew allows the fire products to be released into the cabin. The tests will be fully automated with the data downlinked at the conclusion of the test before the Cygnus vehicle reenters the

  16. Safety aspects of dry spent fuel storage and spent fuel management

    Botsch, W.; Smalian, S.; Hinterding, P.; Voelzke, H.; Wolff, D.; Kasparek, E.

    2014-01-01

    The storage of spent nuclear fuel (SF) and high-level radioactive waste (HLW) must conform to safety requirements. Safety aspects like safe enclosure of radioactive materials, safe removal of decay heat, nuclear criticality safety and avoidance of unnecessary radiation exposure must be achieved throughout the storage period. The implementation of these safety requirements can be achieved by dry storage of SF and HLW in casks as well as in other systems such as dry vault storage systems or spent fuel pools, where the latter is neither a dry nor a passive system. In Germany dual purpose casks for SF or HLW are used for safe transportation and interim storage. TUV and BAM, who work as independent experts for the competent authorities, present the storage licensing process including sites and casks and inform about spent nuclear fuel management and issues concerning dry storage of spent nuclear fuel, based on their long experience in these fields (authors)

  17. Criticality safety of low-density storage arrays

    Bauer, T.H.

    1996-01-01

    This note proposes a straightforward and simple method for the criticality safety analysis of fissionable materials configured into large arrays of standard containers. While criticality-safe storage limits have been well-established for standard containers--even under flooded conditions, it is also necessary to rule out the potential for criticality arising from neutronic interactions among multiple containers that might build up over long distances in a large array. Traditionally, the array problem has been approached by individual Monte Carlo analyses of explicit arrangements of single units and their surroundings. Here, the authors show how multiple Monte Carlo analyses can be usefully combined for wide-ranging general application. The technique takes advantage of low average density of fissionable material in typical storage arrays to separate neutron interactions that take place in the neutron's ''birth unit'' from subsequent interactions in a highly dilute array. Effects of array size, in particular, are conservatively calculated by straightforward analyses which simply smear array contents uniformly across the extent of the array. For given unit loadings in standard containers, practical expressions for neutron multiplication depend only on overall array shape, size and reflective boundary

  18. Fire safety improvement of para-aramid fiber in thermoplastic polyurethane elastomer

    Chen, Xilei; Wang, Wenduo; Li, Shaoxiang; Jiao, Chuanmei

    2017-01-01

    Highlights: • Fire safety of para-aramid fiber on TPU has been investigated. • Para-aramid fiber has excellent flame retardant abilities and smoke suppression properties on TPU. • A new technique to improve the fire safety polymer is provided in this article. - Abstract: This article mainly studied fire safety effects of para-aramid fiber (AF) in thermoplastic polyurethane (TPU). The TPU/AF composites were prepared by molten blending method, and then the fire safety effects of all TPU composites were tested using cone calorimeter test (CCT), microscale combustion colorimeter test (MCC), smoke density test (SDT), and thermogravimetric/fourier transform infrared spectroscopy (TG-IR). The CCT test showed that AF could improve the fire safety of TPU. Remarkably, the peak value of heat release rate (pHRR) and the peak value of smoke production rate (pSPR) for the sample with 1.0 wt% content of AF were decreased by 52.0% and 40.5% compared with pure TPU, respectively. The MCC test showed that the HRR value of AF-2 decreased by 27.6% compared with pure TPU. TG test showed that AF promoted the char formation in the degradation process of TPU; as a result the residual carbon was increased. The TG-IR test revealed that AF had increased the thermal stability of TPU at the beginning and reduced the release of CO_2 with the decomposition going on. Through the analysis of the results of this experiment, it will make a great influence on the study of the para-aramid fiber in the aspect of fire safety of polymer.

  19. Fire safety improvement of para-aramid fiber in thermoplastic polyurethane elastomer

    Chen, Xilei; Wang, Wenduo; Li, Shaoxiang; Jiao, Chuanmei, E-mail: jiaochm@qust.edu.cn

    2017-02-15

    Highlights: • Fire safety of para-aramid fiber on TPU has been investigated. • Para-aramid fiber has excellent flame retardant abilities and smoke suppression properties on TPU. • A new technique to improve the fire safety polymer is provided in this article. - Abstract: This article mainly studied fire safety effects of para-aramid fiber (AF) in thermoplastic polyurethane (TPU). The TPU/AF composites were prepared by molten blending method, and then the fire safety effects of all TPU composites were tested using cone calorimeter test (CCT), microscale combustion colorimeter test (MCC), smoke density test (SDT), and thermogravimetric/fourier transform infrared spectroscopy (TG-IR). The CCT test showed that AF could improve the fire safety of TPU. Remarkably, the peak value of heat release rate (pHRR) and the peak value of smoke production rate (pSPR) for the sample with 1.0 wt% content of AF were decreased by 52.0% and 40.5% compared with pure TPU, respectively. The MCC test showed that the HRR value of AF-2 decreased by 27.6% compared with pure TPU. TG test showed that AF promoted the char formation in the degradation process of TPU; as a result the residual carbon was increased. The TG-IR test revealed that AF had increased the thermal stability of TPU at the beginning and reduced the release of CO{sub 2} with the decomposition going on. Through the analysis of the results of this experiment, it will make a great influence on the study of the para-aramid fiber in the aspect of fire safety of polymer.

  20. FIRE

    Brtis, J.S.; Hausheer, T.G.

    1990-01-01

    FIRE, a microcomputer based program to assist engineers in reviewing and documenting the fire protection impact of design changes has been developed. Acting as an electronic consultant, FIRE is designed to work with an experienced nuclear system engineer, who may not have any detailed fire protection expertise. FIRE helps the engineer to decide if a modification might adversely affect the fire protection design of the station. Since its first development, FIRE has been customized to reflect the fire protection philosophy of the Commonwealth Edison Company. That program is in early production use. This paper discusses the FIRE program in light of its being a useful application of expert system technologies in the power industry

  1. Key Problems of Fire Safety Enforcement in Traffic and Communication Centers (TCC)

    Medyanik, M.; Zosimova, O.

    2017-10-01

    A Traffic and Communication Center (TCC) means facilities designed and used to distribute and redirect flows of humans and motor vehicles while they get serviced and operate. This paper sets forth the basic problems of fire safety enforcement on the TCC, and the causes that slow down human and vehicle traffic speeds. It proposes ways to solve the problems of fire safety enforcement on the TCC, in the Russian Federation and elsewhere. Engineering solutions are proposed for TCC design, with key outlooks of TCC future development as an alternative way to organize access in transportation.

  2. Failure modes of safety-related components at fires on nuclear power plants

    Aaslund, A.

    2000-03-01

    Probabilistic assessment methods can be used to identify specific plant vulnerabilities. Application of such methods can also facilitate selection among system design alternatives available for safety enhancements. The quality of assessment results is however strongly dependent on realistic and accurate input data for modelling of system component behaviour and failure modes during conditions to be assessed. Use of conservative input data may not lead to results providing guidance on safety upgrades. Adequate input data for probabilistic assessments seems to be lacking for at least failure modes of some electrical components when exposed to a fire. This report presents an attempt to improve the situation with respect to such input data. In order to take advantage of information in existing documentation of fire incident occurrences some of the lessons learned from the fire at Browns Ferry Nuclear Power Plant on March 22, 1975 are discussed in this report. Also a summary of results from different fire tests of electrical cables presented in a fire risk analysis report is a part of the references. The failure modes used to describe fire-induced damage are 'open circuit' and 'hot short' which seems to be commonly accepted terms within the branch. Definitions of the terms are included in the report. Effects of the failure modes when occurring in some of the channels of the reactor protection system are discussed with respect to the existing design of the reactor protection system at Ringhals 2 nuclear power unit. Experiences from the Browns Ferry fire and results from fire tests of electrical cables indicate that the dominating failure mode for electrical cables is 'open circuit'. An 'open circuit' failure leads to circuit disjunction and loss of continuity. The circuit can no longer transmit its signal or power. When affecting channels of the reactor protection system an 'open circuit' failure can cause extensive inadvertent actions of safety related equipment

  3. Deep reversible storage. Safety options for the storage in deep geological formation - High-medium activity, long living wastes 2009 milestone

    2010-09-01

    This large document aims at presenting safety options which have been adopted for the current design status (notably for the installation architecture), elements of description of envisaged technical solutions and exploitation principles which are required for the control of risks (either internal or external) and uncertainties on a long term which could lead to radiological consequences for the project of storage of nuclear wastes in a deep geological formation. After a presentation of the context and of input data, this report discusses the principle of a modular construction and then discusses the safety approach. One part deals with risk analysis for surface installations and aims at showing how internal risks (handling, fire) and external risks (earthquake, plane crash) are taken into account in terms of design choices, processes and control measures. Another part deals with risk analysis for underground installations during the reversible exploitation phase (the considered risks are about the same as in the previous part). The next part addresses risk analysis after closing, and tries to describe how the location, storage construction elements and its architecture ensure a passive safety. Uncertainty management is presented in relationship with envisaged technical solutions and scientific knowledge advances. Additional elements (detailed study, researches and experimentations) for the establishment of the future creation authorization request are identified all along the report

  4. Fire criticality probability analysis for 300 Area N Reactor fuel fabrication and storage facility. Revision 1

    Kelly, J.E.

    1995-02-08

    Uranium fuel assemblies and other uranium associated with the shutdown N Reactor are stored in the 300 Area N Reactor Fuel Fabrication and Storage Facility (Facility). The 3712 Building, where the majority of the fuel assemblies and other uranium is stored, is where there could be a potential for a criticality bounding case. The purpose of this study is to evaluate the probability of potential fires in the Facility 3712 Building that could lead to criticality. This study has been done to support the criticality update. For criticality to occur, the wooden fuel assembly containers would have to burn such that the fuel inside would slump into a critical geometry configuration, a sufficient number of containers burn to form an infinite wide configuration, and sufficient water (about a 17 inch depth) be placed onto the slump. To obtain the appropriate geometric configuration, enough fuel assembly containers to form an infinite array on the floor would have to be stacked at least three high. Administrative controls require the stacks to be limited to two high for 1.25 wt% enriched finished fuel. This is not sufficient to allow for a critical mass regardless of the fire and accompanying water moderation. It should be noted that 0.95 wt% enriched fuel and billets are stacked higher than only two high. In this analysis, two initiating events will be considered. The first is a random fire that is hot enough and sufficiently long enough to burn away the containers and fuel separators such that the fuel can establish a critical mass. The second is a seismically induced fire with the same results.

  5. The Storage of Thermal Reactor Safety Analysis data (STRESA)

    Tanarro Colodron, J.

    2016-01-01

    Full text: Storage of Thermal Reactor Safety Analysis data (STRESA) is an online information system that contains three technical databases: 1) European Nuclear Research Facilities, open to all online visitors; 2) Nuclear Experiments, available only to registered users; 3) Results Data, being the core content of the information system, its availability depends on the role and organisation of each user. Its main purpose is to facilitate the exchange of experimental data produced by large Euratom funded scientific projects addressing severe accidents, providing at the same time a secure repository for this information. Due to its purpose and architecture, it has become an important asset for networks of excellence as SARNET or NUGENIA. The Severe Accident ResearchNetwork of Excellence (SARNET)was set up in 2004 under the aegis of the research Euratom Framework Programmes to study severe accidents in watercooled nuclear power plants. Coordinated by the IRSN, SARNET unites 43 organizations involved in research on nuclear reactor safety in 18 European countries plus the USA, Canada, South Korea and India. In 2013, SARNET became fully integrated in the Technical Area N2(TA2), named “Severe accidents” of NUGENIA association, devoted to R&D on fission technology of Generation II and III. (author

  6. Risk-Based Fire Safety Experiment Definition for Manned Spacecraft

    Apostolakis, G. E.; Ho, V. S.; Marcus, E.; Perry, A. T.; Thompson, S. L.

    1989-01-01

    Risk methodology is used to define experiments to be conducted in space which will help to construct and test the models required for accident sequence identification. The development of accident scenarios is based on the realization that whether damage occurs depends on the time competition of two processes: the ignition and creation of an adverse environment, and the detection and suppression activities. If the fire grows and causes damage faster than it is detected and suppressed, then an accident occurred. The proposed integrated experiments will provide information on individual models that apply to each of the above processes, as well as previously unidentified interactions and processes, if any. Initially, models that are used in terrestrial fire risk assessments are considered. These include heat and smoke release models, detection and suppression models, as well as damage models. In cases where the absence of gravity substantially invalidates a model, alternate models will be developed. Models that depend on buoyancy effects, such as the multizone compartment fire models, are included in these cases. The experiments will be performed in a variety of geometries simulating habitable areas, racks, and other spaces. These simulations will necessitate theoretical studies of scaling effects. Sensitivity studies will also be carried out including the effects of varying oxygen concentrations, pressures, fuel orientation and geometry, and air flow rates. The experimental apparatus described herein includes three major modules: the combustion, the fluids, and the command and power modules.

  7. 75 FR 44720 - Safety Zone; Live-Fire Gun Exercise, M/V Del Monte, James River, VA

    2010-07-29

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 165 [Docket No. USCG-2010-0585] RIN 1625-AA00 Safety Zone; Live-Fire Gun Exercise, M/V Del Monte, James River, VA AGENCY: Coast Guard, DHS... follows: Sec. 165.T05-0585 Safety Zone; Live-Fire Gun Exercise, M/V Del Monte, James River, VA (a...

  8. Guidance on the safety assessment methodology for storage of radioactive waste

    Kinyanjui, M.N.

    2014-04-01

    This project on safety assessment on storage was carried out with the main objective of ensuring safety of human life and our environment. This is the fundamental principle of radiation protection. Safety assessment has been evaluated as a tool in the safety case in the pre-construction, operational and the post closure phase of storage. In particular the iterative process of evaluating and predicting safety scenarios at each stage of the process has proved to be prudent. It is important that this concept be adopted for this type of facility to ensure safety of mankind and the environment now and in the future.

  9. Contributions of microgravity test results to the design of spacecraft fire-safety systems

    Friedman, Robert; Urban, David L.

    1993-01-01

    Experiments conducted in spacecraft and drop towers show that thin-sheet materials have reduced flammability ranges and flame-spread rates under quiescent low-gravity environments (microgravity) compared to normal gravity. Furthermore, low-gravity flames may be suppressed more easily by atmospheric dilution or decreasing atmospheric total pressure than their normal-gravity counterparts. The addition of a ventilating air flow to the low-gravity flame zone, however, can greatly enhance the flammability range and flame spread. These results, along with observations of flame and smoke characteristics useful for microgravity fire-detection 'signatures', promise to be of considerable value to spacecraft fire-safety designs. The paper summarizes the fire detection and suppression techniques proposed for the Space Station Freedom and discusses both the application of low-gravity combustion knowledge to improve fire protection and the critical needs for further research.

  10. Tech assist/fire safety assessment of 100K area facilities

    Johnson, B.H.

    1994-01-01

    This Tech Assist/Fire Safety Assessment provides a comprehensive assessment of the 100K Area Facilities at the U.S. Department of Energy's Hanford Site for fire protection upgrades that may be needed given the limited remaining service life of these facilities. This assessment considers the relative nature of observed fire risks and whether the installed fire protection systems adequately control this risk. The analysis is based on compliance with DOE Orders, NFPA Codes and Standards, and recognized industry practice. Limited remaining service life (i.e., 6 to 12 years), current value of each facility, comparison to the best protected class of industrial risk, and the potential for exemptions from DOE requirements are key factors for recommendations presented in this report

  11. Contributions of Microgravity Test Results to the Design of Spacecraft Fire Safety Systems

    Friedman, Robert; Urban, David L.

    1993-01-01

    Experiments conducted in spacecraft and drop towers show that thin-sheet materials have reduced flammability ranges and flame-spread rates under quiescent low-gravity environments (microgravity) as compared to normal gravity. Furthermore, low-gravity flames may be suppressed more easily by atmospheric dilution or decreasing atmospheric total pressure than their normal-gravity counterparts. The addition of a ventilating air flow to the low-gravity flame zone, however, can greatly enhance the flammability range and flame spread. These results, along with observations of flame and smoke characteristics useful for microgravity fire-detection 'signatures', promise to be of considerable value to spacecraft fire-safety designs. The paper summarizes the fire detection and suppression techniques proposed for the Space Station Freedom and discusses both the application of low-gravity combustion knowledge to improve fire protection and the critical needs for further research.

  12. Integrated system of occupational safety and health and fire protection of the fire rescue brigades members.

    Božović, Marijola; Živković, Snežana; Mihajlović, Emina

    2018-06-01

    The objective of the conducted research is the identification and determination of requirements of members of fire rescue brigades during operations in the conditions of high risk in order to minimize the possibilities for injury incidence during the intervention. The research is focused on examination, determination and identification of factors affecting the increasing number of occupational injuries of members of fire rescue brigades during interventions. Hypothetical framework of the research problem consists of general hypothesis and six special hypotheses. Results suggest that almost all respondents believe that their skills and abilities are applicable in the intervention phase, but less than a half believe that their skills are applicable in prevention phase. Two-thirds of respondents stated that in their organization they have support for further education and upgrading while a half of respondents stated that they need education concerning identification, assessment and management of risks that can lead to emergency situations.

  13. An evaluation of The Great Escape: can an interactive computer game improve young children's fire safety knowledge and behaviors?

    Morrongiello, Barbara A; Schwebel, David C; Bell, Melissa; Stewart, Julia; Davis, Aaron L

    2012-07-01

    Fire is a leading cause of unintentional injury and, although young children are at particularly increased risk, there are very few evidence-based resources available to teach them fire safety knowledge and behaviors. Using a pre-post randomized design, the current study evaluated the effectiveness of a computer game (The Great Escape) for teaching fire safety information to young children (3.5-6 years). Using behavioral enactment procedures, children's knowledge and behaviors related to fire safety were compared to a control group of children before and after receiving the intervention. The results indicated significant improvements in knowledge and fire safety behaviors in the intervention group but not the control. Using computer games can be an effective way to promote young children's understanding of safety and how to react in different hazardous situations.

  14. Advances in safety countermeasures at the Tomari NPP of Hokkaido Electric Power on the basis of Fukushima Daiichi NPP accident. Fire protection and other advances

    Shibata, Taku; Dasai, Katsumi

    2014-01-01

    Fire protections for the nuclear power plants have been based on the fire laws and the conventional guide. After Fukushima Daiichi NPP accident, many safety countermeasures - also about Fire Protection - have been discussed in the Japanese authorities. This paper shows our present activities in the Tomari NPP about the fire protections from the view points of Fire Prevention, Fire Detection/Suppression Systems and Fire Protection, and other advances. (author)

  15. Cooperation of the site and public fire and safety services in case of an incident

    Bauch, M.

    1997-01-01

    This report describes the cooperation between the site and the public fire and safety services in case of an incident. As an example, the measures and facilities of the Hoechst site of the Hoechst AG and the organisational and technical background are presented. (orig.) [de

  16. Fire fighting. Measures to guarantee the safety of the radioactive installations

    Orta Aguilera, R.

    1993-01-01

    The work relates the incidence of the aspects related to the fire prevention and fighting as well as the activities of rescue and saving in the radioactive facilities, with the objective of guaranteeing a strict safety regime of all installations along the country so as to reduce to the minimum the risk for the personnel, the population and the environment

  17. Safety considerations and countermeasures against fire and explosion at an HTGR-hydrogen production system. Proposal of safety design concept

    Nishihara, T.; Hada, K.; Shibata, T.; Shiozawa, S.

    1996-01-01

    Establishment of safety design concept and countermeasures against fire and explosion accidents is among key safety-related issues in an HTGR-hydrogen production system. We propose the different safety design concepts depending upon the origin of fire and explosion which may happen in the HTGR-hydrogen production plant. Against fire and explosion originated outside the reactor building (R/B), namely in the area of hydrogen production plant, the safety design concept is primarily to take a safe distance for preventing the damage on safety-related items or a proof wall if necessary. Because the hydrogen production plant is designed in the same safety level as a conventional chemical plant. The safe distance is proposed to limit an incident overpressure to 10 kPa so as not to suffer any damage on the items and to limit a wall-averaged temperature of concrete structures of the R/B to 175degC according to the current regulation. On the other hand, against a potential possibility of explosion originated inside the R/B, the safety design concept is to minimize the possibility of explosion low enough to assume no occurrence inside the R/B. That is, the measure is to exclude a simultaneous failure of a secondary helium piping and an endothermic chemical reactor. Furthermore, in severe accident condition in which the explosion may be postulated a priori, an incidental overpressure of explosion inside the reactor containment vessel (C/V) should be limited so as not to fail the C/V through restricting the amount of combustible gas ingress into the C/V by means of a combination of C/V isolation valve installed in the helium piping and emergency shut off valve in the process feed gas line. (author)

  18. Integral Safety Assessment of Underground Storage of CO2 in Barendrecht, the Netherlands

    Vijgen, L.; Nitert, M.; Buijtendijk, B.; Van Dalen, A.

    2009-10-01

    The DCMR Environmental Protection Agency Rijnmond in the Netherlands conducted an Integral Safety Assessment of Underground Storage of CO2 in Barendrecht, the Netherlands, in cooperation with the involved safety and supervision authorities. The following aspects of the entire storage project and its safety issues have been examined: the compressor station in Pernis; the underground pipes between the compressor station and the injection locations; and the injection locations Barendrecht-Ziedewij and Barendrecht. [nl

  19. Effect of Thermal Storage on the Performance of a Wood Pellet-fired Residential Boiler

    Thomas, Butcher [Brookhaven National Laboratory (BNL), Upton, NY (United States). Sustainable Energy Technologies Dept.

    2017-08-31

    Interest in the direct use of biomass for thermal applications as a renewable technology is increasing as is also focus on air pollutant emissions from these sources and methods to minimize the impact. This work has focused on wood pellet-fired residential boilers, which are the cleanest fuel in this category. In the residential application the load varies strongly over the course of a year and a high fraction of the load is typically under 15% of the maximum boiler capacity. Thermal storage can be used even with boilers which have modulation capacity typically to 30% of the boiler maximum. One common pellet boiler was tested at full load and also at the minimum load used in the U.S. certification testing (15%). In these tests the load was steady over the test period. Testing was also done with an emulated load profile for a home in Albany, N.Y. on a typical January, March, and April day. In this case the load imposed on the boiler varied hourly under computer control, based on the modeled load for the example case used. The boiler used has a nominal output of 25 kW and a common mixed hardwood/softwood commercial pellet was used. Moisture content was 3.77%. A dilution tunnel approach was used for the measurement of particulate emissions, in accordance with U.S. certification testing requirements. The test results showed that the use of storage strongly reduces cycling rates under part load conditions. The transients which occur as these boilers cycle contribute to increased particulate emissions and reduced efficiency. The time period of a full cycle at a given load condition can be increased by increasing the storage tank volume and/or increasing the control differential range. It was shown that increasing the period strongly increased the measured efficiency and reduced the particulate emission (relative to the no storage case). The impact was most significant at the low load levels. Storage tank heat loss is shown to be a significant factor in thermal efficiency

  20. Safety assessment for the above ground storage of Cadmium Safety and Control Rods at the Solid Waste Management Facility

    Shaw, K.W.

    1993-11-01

    The mission of the Savannah River Site is changing from radioisotope production to waste management and environmental restoration. As such, Reactor Engineering has recently developed a plan to transfer the safety and control rods from the C, K, L, and P reactor disassembly basin areas to the Transuranic (TRU) Waste Storage Pads for long-term, retrievable storage. The TRU pads are located within the Solid Waste Management Facilities at the Savannah River Site. An Unreviewed Safety Question (USQ) Safety Evaluation has been performed for the proposed disassembly basin operations phase of the Cadmium Safety and Control Rod Project. The USQ screening identified a required change to the authorization basis; however, the Proposed Activity does not involve a positive USQ Safety Evaluation. A Hazard Assessment for the Cadmium Safety and Control Rod Project determined that the above-ground storage of the cadmium rods results in no change in hazard level at the TRU pads. A Safety Assessment that specifically addresses the storage (at the TRU pads) phase of the Cadmium Safety and Control Rod Project has been performed. Results of the Safety Assessment support the conclusion that a positive USQ is not involved as a result of the Proposed Activity

  1. A safety evaluation of fire and explosion in nuclear fuel reprocessing plants

    Nishio, Gunji; Takada, Junichi; Tukamoto, Michio; Watanabe, Kouji; Miyata, Teijirou

    1996-01-01

    The demonstration test was performed in JAERI to prove the adequacy of a safety evaluation for an air-ventilation system in the case of solvent fire and red-oil explosion in a nuclear fuel reprocessing plant. The test objectives were to obtain data of the safety evaluation on a thermofluid behavior and a confinement effect of radioactive materials during fire and explosion while the system is operating in a cell. The computer code was developed to evaluate the safety of associated network in the ventilation system and to estimate the confinement of radioactive materials in the system. The code was verified by comparison of code calculations with results of the demonstration test. (author)

  2. Statistical assessment of fire safety in multi-residential buildings in Slovenia

    Domen Kušar

    2009-01-01

    Full Text Available Nearly a third of residential units in Slovenia are located in multi-residential buildings. The majority of such buildings were built after WW2, when the need for suitable accommodation buildings was at its peak. They were built using the construction possibilities and requirements of the time. Every year there are over 200 fires in these buildings, resulting in fatalities and vast material damage. Due to the great efforts over the past centuries, which were all mainly aimed at replacing combustible construction materials with non-combustible ones, and with advancements in fire service equipment and techniques, the number of fires and their scope has decreased significantly but they were not entirely put out. New and greater advances in the field of fire safety of multi-residential buildings became obvious within the last few years, when stricter regulations regarding the construction of such objects came into force. Developments in science and within the industry itself brought about several new solutions in improving the situation in this field, which has been confirmed by experiences from abroad. Unfortunately in Slovenia, the establishment of safety principles still depends mainly on an occupants’ perception, financial means, and at the same time, certain implementation procedures that are much more complicated due to new property ownership. With the aid of the statistical results from the 2002 Census and contemporary fire safety requirements, this article attempts to show the present-day situation of the problem at both the state and municipality level and will propose solutions to improve this situation. The authors established that not even one single older, multi-residential building meets complies with modern requirements. Fortunately, the situation is improved by the fact that most buildings in Slovenia are built from non-combustible materials (concrete, brick, which limit the spread of fire.

  3. 30 CFR 75.1903 - Underground diesel fuel storage facilities and areas; construction and safety precautions.

    2010-07-01

    ... areas; construction and safety precautions. 75.1903 Section 75.1903 Mineral Resources MINE SAFETY AND...; construction and safety precautions. (a) Permanent underground diesel fuel storage facilities must be— (1... with at least 240 pounds of rock dust and provided with two portable multipurpose dry chemical type...

  4. SYSTEMS SAFETY ANALYSIS FOR FIRE EVENTS ASSOCIATED WITH THE ECRB CROSS DRIFT

    R. J. Garrett

    2001-01-01

    The purpose of this analysis is to systematically identify and evaluate fire hazards related to the Yucca Mountain Site Characterization Project (YMP) Enhanced Characterization of the Repository Block (ECRB) East-West Cross Drift (commonly referred to as the ECRB Cross-Drift). This analysis builds upon prior Exploratory Studies Facility (ESF) System Safety Analyses and incorporates Topopah Springs (TS) Main Drift fire scenarios and ECRB Cross-Drift fire scenarios. Accident scenarios involving the fires in the Main Drift and the ECRB Cross-Drift were previously evaluated in ''Topopah Springs Main Drift System Safety Analysis'' (CRWMS M and O 1995) and the ''Yucca Mountain Site Characterization Project East-West Drift System Safety Analysis'' (CRWMS M and O 1998). In addition to listing required mitigation/control features, this analysis identifies the potential need for procedures and training as part of defense-in-depth mitigation/control features. The inclusion of this information in the System Safety Analysis (SSA) is intended to assist the organization(s) (e.g., Construction, Environmental Safety and Health, Design) responsible for these aspects of the ECRB Cross-Drift in developing mitigation/control features for fire events, including Emergency Refuge Station(s). This SSA was prepared, in part, in response to Condition/Issue Identification and Reporting/Resolution System (CIRS) item 1966. The SSA is an integral part of the systems engineering process, whereby safety is considered during planning, design, testing, and construction. A largely qualitative approach is used which incorporates operating experiences and recommendations from vendors, the constructor and the operating contractor. The risk assessment in this analysis characterizes the scenarios associated with fires in terms of relative risk and includes recommendations for mitigating all identified hazards. The priority for recommending and implementing mitigation control features is: (1) Incorporate

  5. Safety evaluation of ventilation networks in case of fire

    Perdriau, P.; Pourprix, M.; Raboin, S.; Rouyer, J.L.; Tarrago, X.

    1983-01-01

    Several teams from CEA have cooperated to produce a code for modeling ventilation networks under accidental conditions in nuclear facilities. The objective is to study responses to a network to perturbations which are either mechanical or thermal. Such a tool was necessary for safety and protection studies because ventilation network performances are difficult to evaluate when the network gets complex. There was no requirement for a very sophisticated code, considering the margin of error which generally characterizes the ventilation measurements, but this code should be well validated to become a reliable tool for pointing out safety problems at the design stage and during the operating life of the ventilation system. The code has been called PIAF. It solves a set of equations which simulate a ventilation network in a permanent regime

  6. [Influence of fire disturbance on aboveground deadwood debris carbon storage in Huzhong forest region of Great Xing'an Mountains, Northeast China].

    Yang, Da; He, Hong-shi; Wu, Zhi-wei; Liang, Yu; Huang, Chao; Luo, Xu; Xiao, Jiang-tao; Zhang, Qing-long

    2015-02-01

    Based on the field inventory data, the aboveground deadwood debris carbon storage under different fire severities was analyzed in Huzhong forest region of Great Xing' an Mountains. The results showed that the fire severity had a significant effect on aboveground deadwood debris carbon storage. The deadwood debris carbon storage was in the order of high-severity > low-severity > unburned in Larix gmelinii stands, and mixed conifer-broadleaf stands ( L. gmelinii and Betula platyphylla), and in the order of high severity > unburned > low-severity in B. platyphylla stands. Fire disturbance significantly changed the component percentage of the deadwood debris carbon storage. The component percentage of snags increased and litter decreased with the increasing fire severity. Logs and stumps did not change significantly with the increasing fire severity. The spatial variation of deadwood debris carbon storage in forests burned with low-severity fire was higher than that in unburned forests. The spatial variation of deadwood debris carbon storage with high-severity fires was lowest. This spatial variation needed to be accounted when calculating forest deadwood debris carbon storage.

  7. Safety test of an improved multihundred watt FSA: launch abort, solid propellant fire

    Seabourn, C.M.

    1978-07-01

    This safety test consisted of exposing a simulant-fueled Improved Multihundred Watt Fuel Sphere Assembly, containing a Pt-3008 sphere holding the fuel simulant, to a single proximity fire of UTP-3001 solid rocket propellant for 10.5 min. The graphite outside shell sustained only minor abrasion damage. It was covered on one side with a heavy deposit of alumina from the fire mixed with silica from the test bed. The Pt-3008 shell had small amounts of carbon, alumina, and silica deposited on its surface but sustained no other damage. The PT-3008 sphere was not breached, and therefore the fuel sphere assembly would not release fuel in a solid-propellant fire of a launch abort. 12 figures

  8. International Conference on the Safety of Radioactive Waste Management [Storage: a Necessary Step towards the Endpoints

    Maset, Elvira

    2016-01-01

    Conclusions: • Safety storage for limited periods of time is demonstrated. • Further process of waste or spent fuel can be decided later on a better knowledge and experience. • Storage gives time to achieve disposal sitting and construction, to collect financial resources and to gain public confidence. • Storage facilities tend to excite less public opposition than disposal. • Storage requires the maintenance of the industrial, regulatory and security infrastructure. • It is complementary to disposal but not replace it because active controls cannot be guaranteed in perpetuity. Storage must be as long as necessary but as short as possible

  9. Validation study of computer code SPHINCS for sodium fire safety evaluation of fast reactor

    Yamaguchi, Akira; Tajima, Yuji

    2003-01-01

    A computer code SPHINCS solves coupled phenomena of thermal hydraulics and sodium fire based on a multi-zone model. It deals with an arbitrary number of rooms, each of which is connected mutually by doorways and penetrations. With regard to the combustion phenomena, a flame sheet model and a liquid droplet combustion model are used for pool and spray fires, respectively, with the chemical equilibrium model based on the Gibbs free energy minimization method. The chemical reaction and mass and heat transfer are solved interactively. A specific feature of SPHINCS is detailed representation of thermalhydraulics of a sodium pool and a steel liner, which is placed on the floor to prevent sodium-concrete contact. The authors analyzed a series of pool combustion experiments, in which gas and liner temperatures are measured in detail. It has been found that good agreement is obtained and the SPHINCS code has been validated with regard to pool combustion phenomena. Further research needs are identified for pool spreading modeling considering thermal deformation of steel liner and measurement of pool fluidity property as a mixture of liquid sodium and reaction products. The SPHINCS code is to be used mainly in the safety evaluation of the consequence of a sodium fire accident in a liquid metal cooled fast reactor as well as fire safety analysis in general

  10. Safety test No. S-6, launch pad abort sequential test Phase II: solid propellant fire

    Snow, E.C.

    1975-08-01

    In preparation for the Lincoln Laboratory's LES 8/9 space mission, a series of tests was performed to evaluate the nuclear safety capability of the Multi-Hundred Watt (MHW) Radioisotope Thermoelectric Generator (RTG) to be used to supply power for the satellite. One such safety test is Test No. S-6, Launch Pad Abort Sequential Test. The objective of this test was to subject the RTG and its components to the sequential environments characteristic of a catastrophic launch pad accident to evaluate their capability to contain the 238 PuO 2 fuel. This sequence of environments was to have consisted of the blast overpressure and fragments, followed by the fireball, low velocity impact on the launch pad, and solid propellant fire. The blast overpressure and fragments were subsequently eliminated from this sequence. The procedures and results of Phase II of Test S-6, Solid Propellant Fire are presented. In this phase of the test, a simulant Fuel Sphere Assembly (FSA) and a mockup of a damaged Heat Source Assembly (HSA) were subjected to single proximity solid propellant fires of approximately 10-min duration. Steel was introduced into both tests to simulate the effects of launch pad debris and the solid rocket motor (SRM) casing that might be present in the fire zone. (TFD)

  11. Ongoing enhancements in the German nuclear regulatory framework with respect to fire safety

    Elsche, Bjoern [e.on Kernkraft, Hannover (Germany); Roewekamp, Marina [Gesellschaft fuer Anlagen- und Reaktorsicherheit (GRS) gGmbH, Koeln (Germany); Neugebauer, Wilfried [AREVA NP, Erlangen (Germany); Gersinska, Rainer [Bundesamt fuer Strahlenschutz (BfS), Salzgitter (Germany). KTA-Geschaeftsstelle

    2015-12-15

    In the recent past, the regulatory framework for nuclear power plants (NPP) in Germany has been updated and enhanced comprising on the one hand comprehensive high level regulatory documents such as the 'Safety Requirements for Nuclear Power Plants' and, on the other hand, revised state-of-the-art nuclear safety standards and rules being incorporated in a corresponding legal structure. A major enhancement concerns the nuclear fire and explosion protection standards being already available as so-called green print for final comments which are expected to be officially published end of 2015. The update became necessary after approx. ten years for better addressing some lessons learnt form the operating experience, the consideration of post- Fukushima insights, such as more systematically addressing event combinations with fires and taking into account deviations from non-nuclear standards for escape and rescue routes. Moreover, fire protections remains an important issue for nuclear power plants in Germany during the longer term post-commercial safe shutdown period before decommissioning during which the spent fuel elements remain either in the containment or in the spent fuel pool for further years requiring suitable fire protection means being in place.

  12. Features and safety aspects of spent fuel storage facility, Tarapur

    Pradhan, Sanjay; Dubey, K.; Qureshi, F.T.; Lokeswar, S.P.

    2017-01-01

    Spent Fuel Storage Facility (SFSF), Tarapur is designed to store spent fuel arising from PHWRs in different parts of the country. Spent fuel is transported in AERB qualified/authorized shipping cask by NPCIL to SFSF by road or rail route. The spent fuel storage facility at Tarapur was hot commissioned after regulatory clearances

  13. Fire Safety Consideration in the Pre-conceptual Design State of Pyro-Facillity

    Jeon, Hong Rae; Seo, Seok Jun; Lee, Hyo Jik [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The government, in order to solve this problem, has organized a public engagement committee and is searching for a solution. To use sustainable nuclear energy, our country is also pursuing research and development of fast breeder reactor and pyroprocessing technology in accordance with the international movement of spent fuel recycling and efforts towards nuclear non-proliferation which is centered on the development and demonstration of recycling spent fuel and fast breeder reactors. Pyro-facility has different features with nuclear power plant. In the pyroprocess, chemical and electrochemical separation were took place in the hot cells and material at risk (MAR) is distributed in many working areas. In this paper, we conducted the fire modeling of hot cells to see the stability of pyrophoric materials which is considered as one of the potential hazardous materials in the main process cell. Based on modeling results, consideration of fire safety pyrofacility will be discussed. We performed preliminary hazard analysis for pyrofacility and summarized potential fire hazard. Pyrophoric material fire is the dominant hazard in the main process hot cell and fire modeling of cable tray in the cell was analyzed to see the stability of pyrophoric materials. Analysis results clearly shows that pyrophoric materials are prone to be affected.

  14. Can fire safety in hotels be improved? Results from the survey of a panel of experts in Spain.

    Rubio-Romero, Juan Carlos; Márquez-Sierra, Francisco; Suárez-Cebador, Manuel

    2016-06-08

    The hotel industry is an important driver of the European labour market with over 250,000 hotels employing some 2 million people. In Spain, 240 workers were injured by fires in hotels from 2004 to 2008. Fire is considered to be the most important risk in the hotel industry, but the lack of an EU-wide data recording system for hotels makes it difficult to give exact figures for fire events. We analysed the state of fire prevention systems in hotels in Spain with the aim of proposing strategies to improve fire safety. A 10-item questionnaire was administered from 2007 to 2009 to 15 Spanish experts in fire safety. The questions were measured using a Likert scale and classified into 4 sections: current state of installations, influence of establishment characteristics, application of regulations and priority ranking of actions. Descriptive statistics summarized the data and t-tests evaluated the agreement foreach statement in the questionnaire. The statistical analysis showed homogeneity in the responses by the experts in all four categories: current state of fire safety installations, influence of establishment characteristics, application of regulations, and priority of actions. There was consensus among the experts over the necessity to improve the enforcement of regulations and also regarding the existence of an association between the hotel category (in Spain they are ranked using a 1 to 5 "star" rating system) and the level of fire safety; hotels with a higher category had higher levels of safety. There is a need to identify ways to apply fire safety standards to older hotels so that they comply with new regulations, to standardize regulations for different regions and countries, to improve the maintenance of installations and equipment, to increase the effectiveness of inspections conducted by government bodies, and to raise the general awareness of stakeholders involved in hotel fire prevention.

  15. Criticality Safety Evaluation of Hanford Site High Level Waste Storage Tanks

    ROGERS, C.A.

    2000-02-17

    This criticality safety evaluation covers operations for waste in underground storage tanks at the high-level waste tank farms on the Hanford site. This evaluation provides the bases for criticality safety limits and controls to govern receipt, transfer, and long-term storage of tank waste. Justification is provided that a nuclear criticality accident cannot occur for tank farms operations, based on current fissile material and operating conditions.

  16. Criticality Safety Evaluation of Hanford Site High-Level Waste Storage Tanks

    ROGERS, C.A.

    2000-01-01

    This criticality safety evaluation covers operations for waste in underground storage tanks at the high-level waste tank farms on the Hanford site. This evaluation provides the bases for criticality safety limits and controls to govern receipt, transfer, and long-term storage of tank waste. Justification is provided that a nuclear criticality accident cannot occur for tank farms operations, based on current fissile material and operating conditions

  17. Happy 50th Birthday Smokey Bear! A Learning Kit about Forests and Fire Safety for Grades K-3.

    Hall, Meryl

    For over 50 years, the primary goal of Smokey Bear has been to introduce the forest fire prevention message to young children. This learning kit provides the K-3 teacher with activities and resources to help students learn about Smokey Bear and fire safety, about forests as habitats, and about what they can do to protect forests. Students are…

  18. A study on fire spreading model for the safety distance between the neighborhood occupancies and historical buildings in Taiwan

    Chen, C. H.; Chien, S. W.; Ho, M. C.

    2015-08-01

    Cultural heritages and historical buildings are vulnerable against severe threats from fire. Since the 1970s, ten fire-spread events involving historic buildings have occurred in Taiwan, affecting a total of 132 nearby buildings. Developed under the influence of traditional Taiwanese culture, historic buildings in Taiwan are often built using non-fire resistant brick-wood structure and located in proximity to residential occupancies. Fire outbreak in these types of neighborhood will lead to severe damage of antiquities, leaving only unrecoverable historical imagery. This study is aimed to investigate the minimal safety distance required between a historical building and its surroundings in order to reduce the risk of external fire. This study is based on literature analysis and the fire spread model using a Fire Dynamics Simulator. The selected target is Jingmei Temple in Taipei City. This study explored local geography to identify patterns behind historical buildings distribution. In the past, risk reduction engineering for cultural heritages and historical buildings focused mainly on fire equipment and the available personnel with emergency response ability, and little attention was given to external fire risks and the affected damage. Through discussions on the required safety distance, this research provides guidelines for the following items: management of neighborhoods with historical buildings and consultation between the protection of cultural heritages and disaster prevention, reducing the frequency and extent of fire damages, and preserving cultural resource.

  19. Long-term storage of radioactive waste: IAEA perspectives on safety and sustainability

    Rowat, J.H.; Louvat, D.; Metcalf, P.E.

    2006-01-01

    As the amounts of radioactive waste in surface storage have increased, concern has grown over the safety and sustainability of storage in the long term. In response to increasing concerns, the International Atomic Energy Agency (IAEA) has included an action to address the safety implications of the long-term storage (LTS) of radioactive waste in its action plan for waste safety; the action plan was endorsed by the IAEA's Member States in 2001. In 2003, the IAEA published a position paper on the safety and sustainability of LTS as part fulfilment of the action in question. A key theme of the position paper is the contrast of safety and sustainability implications of LTS with those of disposal. The present paper provides a summary of the position paper, describes current IAEA activities that deal with the subject of LTS, and discusses findings from the 2004 Cordoba symposium on disposal of low activity radioactive waste that pertain to LTS. (author)

  20. Safety analysis of spent fuel transport and storage casks under extreme impact conditions

    Wolff, D.; Wieser, G.; Ballheimer, V.; Voelzke, H.; Droste, B.

    2005-01-01

    Full text: Worldwide the security of transport and storage of spent fuel with respect to terrorism threats is a matter of concern. In Germany a spent nuclear fuel management program was developed by the government including a new concept of dry on-site interim storage instead of centralized interim storage. In order to minimize transports of spent fuel casks between nuclear power plants, reprocessing plants and central storage facilities, the operators of NPPs have to erect and to use interim storage facilities for spent nuclear fuel on the site or in the vicinity of nuclear power plants. Up to now, 11 on-site interim storage buildings, one storage tunnel and 4 on-site interim storage areas (preliminary cask storage till the on-site interim storage building is completed) have been licensed at 12 nuclear power plant sites. Inside the interim storage buildings the casks are kept in upright position, whereas at the preliminary interim storage areas horizontal storage of the casks on concrete slabs is used and each cask is covered by concrete elements. Storage buildings and concrete elements are designed only for gamma and neutron radiation shielding reasons and as weather protection. Therefore the security of spent fuel inside a dual purpose transport and storage cask depends on the inherent safety of the cask itself. For nearly three decades BAM has been investigating cask safety under severe accident conditions like drop tests from more than 9 m onto different targets and without impact limiters as well as artificially damaged prototype casks. Since the terror attacks of 11 September 2001 the determination of casks' inherent safety also under extreme impact conditions due to terrorist attacks has been of our increasing interest. With respect to spent fuel storage one of the most critical scenarios of a terrorist attack for a cask is the centric impact of a dynamic load onto the lid-seal-system caused e.g. by direct aircraft crash or its engine as well as by a

  1. Ensuring Reliable Natural Gas-Fired Generation with Fuel Contracts and Storage - DOE/NETL-2017/1816

    Myles, Paul T. [National Energy Technology Lab. (NETL), Albany, OR (United States); Labarbara, Kirk A. [National Energy Technology Lab. (NETL), Albany, OR (United States); Logan, Cecilia Elise [National Energy Technology Lab. (NETL), Albany, OR (United States)

    2017-11-17

    This report finds that natural gas-fired power plants purchase fuel both on the spot market and through firm supply contracts; there do not appear to be clear drivers propelling power plants toward one or the other type. Most natural gas-fired power generators are located near major natural gas transmission pipelines, and most natural gas contracts are currently procured on the spot market. Although there is some regional variation in the type of contract used, a strong regional pattern does not emerge. Whether gas prices are higher with spot or firm contracts varies by both region and year. Natural gas prices that push the generators higher in the supply curve would make them less likely to dispatch. Most of the natural gas generators discussed in this report would be unlikely to enter firm contracts if the agreed price would decrease their dispatch frequency. The price points at which these generators would be unlikely to enter a firm contract depends upon the region that the generator is in, and how dependent that region is on natural gas. The Electric Reliability Council of Texas (ERCOT) is more dependent on natural gas than either Eastern Interconnection or Western Interconnection. This report shows that above-ground storage is prohibitively expensive with respect to providing storage for an extended operational fuel reserve comparable to the amount of on-site fuel storage used for coal-fired plants. Further, both pressurized and atmospheric tanks require a significant amount of land for storage, even to support one day’s operation at full output. Underground storage offers the only viable option for 30-day operational storage of natural gas, and that is limited by the location of suitable geologic formations and depleted fields.

  2. Fire barrier evaluation of the wall between spent nuclear fuel storage basins and reactor areas, 105KE and 105KW

    Johnson, B.H.

    1994-01-01

    This evaluation is intended to provide a comprehensive assessment of the risks from fire and fire related perils for the fire barriers between spent nuclear fuel storage basins and reactor areas, 105KE and 105KW. As a result of this fire barrier evaluation the present walls and the components thereof are not a true listed fire rated assembly. However, due to the construction of these barriers and the components thereof, these barriers will provide an equivalent level of protection provided the recommendations in Section 8.0 of this report are completed. These recommended upgrades are based upon sound engineering practice by a Registered Fire Protection Engineer. The construction of the barrier are substantial enough to provide the required 2-hr fire resistance rating. The primary concern is the numerous penetrations in the barrier. There are many penetrations that are adequate and no additional work is required. These penetrations are the ones that were poured-in-place at the time of construction. The penetrations that are of concern are some of the doors, the HVAC ducts, and the unsealed piping and conduit penetrations. There are several metal doors that should be replaced because the existing doors have either a non-approved window or louver that will not limit the spread of fire to one side of the barrier. All unsealed piping and conduit penetrations should be firestopped with an approved firestopping material. The existing non-active ducts that pass through the barrier should be disconnected at the barrier and the opening sealed with an approved firestopping method

  3. A guideline for fire prevention during the storage of biomass; Leitfaden zur Brandvermeidung bei der Lagerung von Biomasse

    Ferrero, Fabio; Malow, Marcus; Schmidt, Martin; Krause, Ulrich

    2009-10-14

    For five years, an increasing number of fires in timber-yards is observed. A multiplicity of these fires results from self inflammation of the material. Under this aspect, the contribution under consideration reports on the fundamentals of the self inflammation by biomass using wood as an example. The methodology for the avoidance of the self inflammation of biomass is based on a combination of laboratory tests and numeric simulation in order to determine the reliable waste dump geometry and storage times. In particular, the humidity content of the stored material is very important for growth and heat production of the micro organisms. If the material does not possess optimal humidity content, heat production and the probability of self inflammation are reduced. The optimal content of humidity amounts nearly 50-60 mass-%. For the determination of a safe storage of biomass, a flow chart is developed using pinewood as an example. (orig.)

  4. A novel method to design water spray cooling system to protect floating roof atmospheric storage tanks against fires

    Iraj Alimohammadi

    2015-01-01

    Full Text Available Hydrocarbon bulk storage tank fires are not very common, but their protection is essential due to severe consequences of such fires. Water spray cooling system is one of the most effective ways to reduce damages to a tank from a fire. Many codes and standards set requirements and recommendations to maximize the efficiency of water spray cooling systems, but these are widely different and still various interpretations and methods are employed to design such systems. This article provides a brief introduction to some possible design methods of cooling systems for protection of storage tanks against external non-contacting fires and introduces a new method namely “Linear Density Method” and compares the results from this method to the “Average Method” which is currently in common practice. The average Method determines the flow rate for each spray nozzle by dividing the total water demand by the number of spray nozzles while the Linear Density Method determines the nozzle flow rate based on the actual flow over the surface to be protected. The configuration of the system includes a one million barrel crude oil floating roof tank to be protected and which is placed one half tank diameter from a similar adjacent tank with a full surface fire. Thermal radiation and hydraulics are modeled using DNV PHAST Version 6.53 and Sunrise PIPENET Version 1.5.0.2722 software respectively. Spray nozzles used in design are manufactured by Angus Fire and PNR Nozzles companies. Schedule 40 carbon steel pipe is used for piping. The results show that the cooling system using the Linear Density Method consumes 3.55% more water than the design using the average method assuming a uniform application rate of 4.1 liters per minute. Despite higher water consumption the design based on Linear Density Method alleviates the problems associated with the Average Method and provides better protection.

  5. Criticality Safety Problems Related to Storage of Highly Active Liquid Waste

    Amin, E.

    1999-01-01

    The geometries of liquid waste storage tanks are not generally safe against criticality. Normally, this does not cause problems as fissile materials exist in nitric acid solution only as depleted uranium or in insignificant concentration of the originally reprocessed inventory of plutonium. However, if sedimentation of solid particles would occur, the deposited material would cause criticality safety problems. Particularly, non-horizontal installation of the storage tanks would increase the Eigen value. The effect of the storage tank inclination and the presence of transplutonium elements on the criticality safety are investigated using the NCNSRC code packages. The results are compared well with a similar German published results

  6. Fire safety of historical buildings traditional versus innovative “behavioural design” solutions by using wayfinding systems

    Bernardini, Gabriele

    2017-01-01

    This book applies a behavioral point of view to individuals’ fire safety in historic buildings. It outlines theoretical and operative issues, based on recent studies and international guidelines. Firstly, critical issues for Building Heritage fire safety are widely discussed, by including the modelling of human factor and man-environment-fire interference in these architectural spaces. A significant part of the book includes a discussion on emergency modeling and simulation. A source code for representing the fire evacuation process (including man-evacuation facilities interactions) is offered to the reader. Methods for effectiveness assessment of risk-reducing solutions are provided and tested in a case-study. Being a structured approach to occupants-related problems during a fire in heritage buildings, it offers an innovative methodology and practical examples that researchers and designers can use as a guide when proposing and testing solutions. Evaluation indexes for effectiveness assessment (also usefu...

  7. General safety guidelines for looking for a low mass activity-long life waste storage site

    2008-01-01

    The objective of this document is to define general guidelines which must be followed during the stages of search for a site and stages of design of a storage facility for low activity-long life radioactive wastes, in order to ensure its safety after closure. After having specified the considered wastes, geological shapes, and situations, this document defines the fundamental objective and the associated criteria (protection against chemical risk, radioprotection). It presents the design aspects related to safety (safety principles and functions, waste packages, public works engineering, geological environment, storage concepts). The last part deals with the safety demonstration after site closure which includes the control of some components, the assessment of disturbances in the storage facility or due to its presence, the taking of uncertainty and sensitivity studies into account, the influence of natural events

  8. Final safety analysis report for the irradiated fuels storage facility

    Bingham, G.E.; Evans, T.K.

    1976-01-01

    A fuel storage facility has been constructed at the Idaho Chemical Processing Plant to provide safe storage for spent fuel from two commercial HTGR's, Fort St. Vrain and Peach Bottom, and from the Rover nuclear rocket program. The new facility was built as an addition to the existing fuel storage basin building to make maximum use of existing facilities and equipment. The completed facility provides dry storage for one core of Peach Bottom fuel (804 elements), 1 1 / 2 cores of Fort St. Vrain fuel (2200 elements), and the irradiated fuel from the 20 reactors in the Rover program. The facility is designed to permit future expansion at a minimum cost should additional storage space for graphite-type fuels be required. A thorough study of the potential hazards associated with the Irradiated Fuels Storage Facility has been completed, indicating that the facility is capable of withstanding all credible combinations of internal accidents and pertinent natural forces, including design basis natural phenomena of a 10,000 year flood, a 175-mph tornado, or an earthquake having a bedrock acceleration of 0.33 g and an amplification factor of 1.3, without a loss of integrity or a significant release of radioactive materials. The design basis accident (DBA) postulated for the facility is a complete loss of cooling air, even though the occurrence of this situation is extremely remote, considering the availability of backup and spare fans and emergency power. The occurrence of the DBA presents neither a radiation nor an activity release hazard. A loss of coolant has no effect upon the fuel or the facility other than resulting in a gradual and constant temperature increase of the stored fuel. The temperature increase is gradual enough that ample time (28 hours minimum) is available for corrective action before an arbitrarily imposed maximum fuel centerline temperature of 1100 0 F is reached

  9. Automated Storage Retrieval System (ASRS) Role Towards Achievement of Safety Objective and Safety Culture in Radioactive Storage Facilities

    Mohamad Hakiman Mohd Yusoff; Nurul Wahida Ahmad Khairuddin; Nik Marzukee Nik Ibrahim; Mat Bakar Mahusin; Muhammad, Z.A.; Nur Azna Mahmud; Norfazlina Zainal Abidin

    2012-01-01

    Waste Technology Development Centre (WasTeC) has been awarded with quality management system ISO 9001:2000 in June 2004 or now known as ISO 9001:2008. The scope of the unit's ISO certification is radioactive waste management and storage of radioactive material. To meet the objectives and requirements ISO 9001:2008, WasTeC has started a project known as Automated Storage and Retrieval System (ASRS). ASRS is a computing controlled method for automatically depositing and retrieving waste from defined locations. The system is used to replace the existing process of storage and retrieval of radioactive waste at storage facility at block 33.The main objective of this project is to reduced the radiation exposure to the worker and potential forklift accident occur during storage and retrieval of the radioactive waste. By using the ASRS system, WasTeC/ Nuclear Malaysia can provide a safe storage of radioactive waste and the use of this system can eliminate the repeat handling and can improve productivity. (author)

  10. Health and safety manual

    1980-02-01

    The manual consists of the following chapters: general policies and administration; the Environmental Health and Safety Department; the Medical Services Department: biological hazards; chemical safety; confined space entry; cryogenic safety; electrical safety; emergency plans; engineering and construction; evacuations, trenching, and shoring; fire safety; gases, flammable and compressed; guarding, mechanical; ladders and scaffolds, work surfaces; laser safety; materials handling and storage; noise; personal protective equipment; pressure safety; radiation safety, ionizing and non-ionizing; sanitation; seismic safety; training, environmental health and safety; tools, power and hand-operated; traffic and transportation; and warning signs and devices

  11. Canister Storage Building (CSB) safety analysis report, phase 3: Safety analysis documentation supporting CSB construction

    Garvin, L.J.

    1997-01-01

    The US Department of Energy established the K Basins Spent Nuclear Fuel Project to address safety and environmental concerns associated with deteriorating spent nuclear fuel presently stored under water in the Hanford Site's K Basins, which are located near the Columbia River. Recommendations for a series of aggressive projects to construct and operate systems and facilities to manage the safe removal of K Basins fuel were made in WHC-EP-0830, Hanford Spent Nuclear Fuel Recommended Path Forward, and its subsequent update, WHC-SD-SNF-SP-005, Hanford Spent Nuclear Fuel Project Integrated Process Strategy for K Basins Fuel. The integrated process strategy recommendations include the following steps: Fuel preparation activities at the K Basins, including removing the fuel elements from their K Basin canisters, separating fuel particulate from fuel elements and fuel fragments greater than 0.6 cm (0.25 in.) in any dimension, removing excess sludge from the fuel and fuel fragments by means of flushing, as necessary, and packaging the fuel into multicanister overpacks (MCOs); Removal of free water by draining and vacuum drying at a cold vacuum drying facility ES-122; Dry shipment of fuel from the Cold Vacuum Drying to the Canister Storage Building (CSB), a new facility in the 200 East Area of the Hanford Site

  12. A Survey of a System of Methods for Fire Safety Design of Traditional Concrete Constructions

    Hertz, Kristian

    2000-01-01

    constructions DS411. And the bases for many of the methods have been distributed by CIB W14 reports. But a survey of all the methods in coherence has never been presented, and much of this documentation and the additional documentation produced for the work with the codes needs still to be printed in papers......During the years since 1978 the author has been developing a series of calculation methods and sup-porting test methods for the fire safety design of concrete constructions. The basic methods have been adopted in the fire chapters of the Eurocode ENV1992-1-2 and the Danish code for concrete.......It is the aim of this paper to give a coherent presentation of the design methods, their degree of documentation and the available references in order to facilitate the application of them....

  13. Classification of transportation packaging and dry spent fuel storage system components according to importance to safety

    Tyacke, M.J.; McConnell, J.W. Jr.; Ayers, A.L. Jr.; O'Connor, S.C.; Jankovich, J.P.

    1996-01-01

    The Idaho National Engineering Laboratory prepared a technical report for the Office of Nuclear Material Safety and Safeguards of the US Nuclear Regulatory Commission, entitled Classification of Transportation Packaging and Dry Spent Fuel Storage System Components According to Importance to Safety, NUREG/CR-6407. This paper provides the results of that report. It also presents the graded approach for classification of components used in transportation packagings and dry spent fuel storage systems. This approach provides a method for identifying the classification of components according to importance to safety within transportation packagings and dry spent fuel storage systems. Record retention requirements are discussed to identify the documentation necessary to validate that the individual components were fabricated in accordance with their assigned classification. A review of the existing regulations pertaining to transportation packagings and dry storage systems was performed to identify current requirements. The general types of transportation packagings and dry storage systems are identified. The methodology used in this paper is based on Regulatory Guide 7.10, Establishing Quality Assurance Programs for Packaging Used in the Transport of Radioactive Material. This paper also includes a list of generic components for each of the general types of transportation packagings and spent fuel storage systems, with a classification category assigned to each component. Several examples concerning the safety importance of components are presented

  14. Problems and experience of ensuring nuclear safety in NPP spent fuel storage facilities in Russia

    Vnukov, Victor S.; Ryazanov, Boris G.

    2003-01-01

    The amount of Nuclear Power Plant (NPP) spent fuel in special storage facilities of Russia runs to more than 15000 tons and the annual growth is equal to about 850 tons. The storage facilities for spent nuclear fuel from the main nuclear reactors of Russia (RBMK-1000, VVER-1000, BN-600, EGP-6) were designed in the 60s - 70s. In the last years when the concept of closed fuel cycle and safety requirements had changed, the need was generated to have the nuclear storage facilities more crowded. First of all it is due to the necessity to increase the storage capacity because the RBMK-1000, VVER-1000, EGP-6 fuel is not reprocessed. So there comes the need for the facilities of a bigger capacity which meet the current safety requirements. The paper presents the results of studies of the most important nuclear safety issues, in particular: development of regulatory requirements; analysis of design-basis and beyond-the design-basis accidents (DBA and BDBA); computation code development and verification; justification of nuclear safety when water density goes down; the use of burn-up fraction values; the necessity and possibility to experimentally study the storage facility subcriticality; development of storage norms and rules for new types of fuel assemblies with mixed fuel and burnable poison. (author)

  15. Preliminary safety evaluation (PSE) for Sodium Storage Facility at the Fast Flux Test Facility

    Bowman, B.R.

    1994-01-01

    This evaluation was performed for the Sodium Storage Facility (SSF) which will be constructed at the Fast Flux Test Facility (FFTF) in the area adjacent to the South and West Dump Heat Exchanger (DHX) pits. The purpose of the facility is to allow unloading the sodium from the FFTF plant tanks and piping. The significant conclusion of this Preliminary Safety Evaluation (PSE) is that the only Safety Class 2 components are the four sodium storage tanks and their foundations. The building, because of its imminent risk to the tanks under an earthquake or high winds, will be Safety Class 3/2, which means the building has a Safety Class 3 function with the Safety Class 2 loads of seismic and wind factored into the design

  16. A consideration of hazards, earthquakes, aircraft crashes, explosions and fires in the safety of laboratories and plants

    Doumenc, A.; Faure, J.; Mohammadioun, B.; Jacquet, P.

    1987-03-01

    Although laboratories and plants differ from nuclear reactors both in their characteristics and sitings, safety measures developed for the hazards of earthquakes, aircraft crashes, explosions and fires are very similar. These measures provide a satisfactory level of safety for these installations [fr

  17. Safety assessment of VHTR hydrogen production system against fire, explosion and acute toxicity

    Murakami, Tomoyuki; Nishihara, Tetsuo; Kunitomi, Kazuhiko

    2008-01-01

    The Japan Atomic Energy Agency has been developing a nuclear hydrogen production system by using heat from the Very High Temperature Reactor (VHTR). This system will handle a large amount of combustible gas and toxic gas. The risk from fire, explosion and acute toxic exposure caused by an accident involving chemical material release in a hydrogen production system is assessed. It is important to ensure the safety of the nuclear plant, and the risks for public health should be sufficiently small. This report provides the basic policy for the safety evaluation in cases of accident involving fire, explosion and toxic material release in a hydrogen production system. Preliminary safety analysis of a commercial-sized VHTR hydrogen production system, GTHTR300C, is performed. This analysis provides us with useful information on the separation distance between a nuclear plant and a hydrogen production system and a prospect that an accident in a hydrogen production system does not significantly increase the risks of the public. (author)

  18. Enhanced safety in the storage of fissile materials

    Williams, G.E.; Alvares, N.J.

    1979-01-01

    A ''plastic-like'' supporting material impregnated with a neutron-absorbing agent that is suitable for ''lining'' the inner surfaces of fissile-material storage containers was fabricated. The material consists, by weight, of 50% food-grade borax, 25% coal tar, and 25% epoxy resin. It costs much less than commercially available materials, can absorb enough neutrons to isolate units of fissile material, and possesses such structural qualities as flexibility and machinability. Properties and performance of the material are discussed

  19. Safety of atmospheric storage tanks during accidental explosions

    Noret , E.; Prod'Homme , Gaëtan; Yalamas , Thierry; Reimeringer , Mathieu; Hanus , Jean-Luc; Duong , Duy-Hung

    2012-01-01

    International audience; The occurrence of a chain reaction from blast on atmospheric storage tanks in oil and chemical facilities is hard to predict. The current French practice for SEVESO facilities ignores projectiles and assumes a critical peak overpressure value observed from accident data. This method could lead to conservative or dangerous assessments. This study presents various simple mechanical models to facilitate quick effective assessment of risk analysis, the results of which are...

  20. Follow-up of foreign safety studies of final storage of nuclear fuel waste

    Gelin, R.

    1985-04-01

    The development of mathematical models and calculation programs for estimating radionuclide migration from radioactive waste storage is continuing. Detailed site studies are in progress in the United States. The Swiss investigation which has been recently published, recommends waste storage in granite at the depth of 1200 m. The safety analysis is similar to the one of the Swedish KBS-3 study. 68 references. (G.B.)

  1. Radioprotection and safety for a dry storage module for bare PWR fuel elements

    Tzontlimatzin, E.

    1983-01-01

    A module for dry storage of spent fuel from PWR, after a previous cooling time of 2 years, is examined. Biological protection is obtained by 185 cm of concrete. The safety study shows the impossibility of a fast increase in temperature in case of cooling system failure because in this case the module will be cooled by natural convection or thermosiphon. A project for a storage installation consisting of 5 modules for 1500 irradiated fuel assemblies is described [fr

  2. Final hazard classification and auditable safety analysis for the 105-C Reactor Interim Safe Storage Project

    Rodovsky, T.J.; Larson, A.R.; Dexheimer, D.

    1996-12-01

    This document summarizes the inventories of radioactive and hazardous materials present in the 105-C Reactor Facility and the operations associated with the Interim Safe Storage Project which includes decontamination and demolition and interim safe storage of the remaining facility. This document also establishes a final hazard classification and verifies that appropriate and adequate safety functions and controls are in place to reduce or mitigate the risk associated with those operations

  3. Opportunities for Decarbonizing Existing U.S. Coal-Fired Power Plants via CO2 Capture, Utilization and Storage.

    Zhai, Haibo; Ou, Yang; Rubin, Edward S

    2015-07-07

    This study employs a power plant modeling tool to explore the feasibility of reducing unit-level emission rates of CO2 by 30% by retrofitting carbon capture, utilization, and storage (CCUS) to existing U.S. coal-fired electric generating units (EGUs). Our goal is to identify feasible EGUs and their key attributes. The results indicate that for about 60 gigawatts of the existing coal-fired capacity, the implementation of partial CO2 capture appears feasible, though its cost is highly dependent on the unit characteristics and fuel prices. Auxiliary gas-fired boilers can be employed to power a carbon capture process without significant increases in the cost of electricity generation. A complementary CO2 emission trading program can provide additional economic incentives for the deployment of CCS with 90% CO2 capture. Selling and utilizing the captured CO2 product for enhanced oil recovery can further accelerate CCUS deployment and also help reinforce a CO2 emission trading market. These efforts would allow existing coal-fired EGUs to continue to provide a significant share of the U.S. electricity demand.

  4. Annex D-200 Area Interim Storage Area Final Safety Analysis Report [FSAR] [Section 1 and 2

    CARRELL, R.D.

    2002-01-01

    The 200 Area Interim Storage Area (200 Area ISA) at the Hanford Site provides for the interim storage of non-defense reactor spent nuclear fuel (SNF) housed in aboveground dry cask storage systems. The 200 Area ISA is a relatively simple facility consisting of a boundary fence with gates, perimeter lighting, and concrete and gravel pads on which to place the dry storage casks. The fence supports safeguards and security and establishes a radiation protection buffer zone. The 200 Area ISA is nominally 200,000 ft 2 and is located west of the Canister Storage Building (CSB). Interim storage at the 200 Area ISA is intended for a period of up to 40 years until the materials are shipped off-site to a disposal facility. This Final Safety Analysis Report (FSAR) does not address removal from storage or shipment from the 200 Area ISA. Three different SNF types contained in three different dry cask storage systems are to be stored at the 200 Area ISA, as follows: (1) Fast Flux Test Facility Fuel--Fifty-three interim storage casks (ISC), each holding a core component container (CCC), will be used to store the Fast Flux Test Facility (FFTF) SNF currently in the 400 Area. (2) Neutron Radiography Facility (NRF) TRIGA'--One Rad-Vault' container will store two DOT-6M3 containers and six NRF TRIGA casks currently stored in the 400 Area. (3) Commercial Light Water Reactor Fuel--Six International Standards Organization (ISO) containers, each holding a NAC-I cask4 with an inner commercial light water reactor (LWR) canister, will be used for commercial LWR SNF from the 300 Area. An aboveground dry cask storage location is necessary for the spent fuel because the current storage facilities are being shut down and deactivated. The spent fuel is being transferred to interim storage because there is no permanent repository storage currently available

  5. Annex D-200 Area Interim Storage Area Final Safety Analysis Report [FSAR] [Section 1 & 2

    CARRELL, R D

    2002-07-16

    The 200 Area Interim Storage Area (200 Area ISA) at the Hanford Site provides for the interim storage of non-defense reactor spent nuclear fuel (SNF) housed in aboveground dry cask storage systems. The 200 Area ISA is a relatively simple facility consisting of a boundary fence with gates, perimeter lighting, and concrete and gravel pads on which to place the dry storage casks. The fence supports safeguards and security and establishes a radiation protection buffer zone. The 200 Area ISA is nominally 200,000 ft{sup 2} and is located west of the Canister Storage Building (CSB). Interim storage at the 200 Area ISA is intended for a period of up to 40 years until the materials are shipped off-site to a disposal facility. This Final Safety Analysis Report (FSAR) does not address removal from storage or shipment from the 200 Area ISA. Three different SNF types contained in three different dry cask storage systems are to be stored at the 200 Area ISA, as follows: (1) Fast Flux Test Facility Fuel--Fifty-three interim storage casks (ISC), each holding a core component container (CCC), will be used to store the Fast Flux Test Facility (FFTF) SNF currently in the 400 Area. (2) Neutron Radiography Facility (NRF) TRIGA'--One Rad-Vault' container will store two DOT-6M3 containers and six NRF TRIGA casks currently stored in the 400 Area. (3) Commercial Light Water Reactor Fuel--Six International Standards Organization (ISO) containers, each holding a NAC-I cask4 with an inner commercial light water reactor (LWR) canister, will be used for commercial LWR SNF from the 300 Area. An aboveground dry cask storage location is necessary for the spent fuel because the current storage facilities are being shut down and deactivated. The spent fuel is being transferred to interim storage because there is no permanent repository storage currently available.

  6. Transuranic waste storage and assay facility (TRUSAF) interim safety basis

    Gibson, K.D.

    1995-09-01

    The TRUSAF ISB is based upon current facility configuration and procedures. The purpose of the document is to provide the basis for interim operation or restrictions on interim operations and the authorization basis for the TRUSAF at the Hanford Site. The previous safety analysis document TRUSAF hazards Identification and Evaluation (WHC 1977) is superseded by this document

  7. INFLUENCE OF SOFT MEAT PRODUCTS STORAGE ON THEIR MICROBIOLOGICAL SAFETY

    Jana Kopčeková

    2010-07-01

    Full Text Available The aim of the topic was to analyze the microbiological quality of soft meat products (ham sausage in relation to the retention period. We focused on the determination of total count of microorganisms, Enterobacteriaceae and coliforms. The results shown that the strongest growth of microorganisms was recorded at the 21st storage day of ham at 2 to 6 °C. It is essential to keep the cold chain and to comply with the requirements set by the manufacturer.  doi:10.5219/20

  8. INFLUENCE OF SOFT MEAT PRODUCTS STORAGE ON THEIR MICROBIOLOGICAL SAFETY

    Jana Kopčeková; Kristína Kulichová; Lucia Zeleňáková

    2010-01-01

    The aim of the topic was to analyze the microbiological quality of soft meat products (ham sausage) in relation to the retention period. We focused on the determination of total count of microorganisms, Enterobacteriaceae and coliforms. The results shown that the strongest growth of microorganisms was recorded at the 21st storage day of ham at 2 to 6 °C. It is essential to keep the cold chain and to comply with the requirements set by the manufacturer.  doi:10.5219/20

  9. 77 FR 32394 - Safety Zones: Catawba Island Club Fire Works, Catawba Island Club, Port Clinton, OH; Racing for...

    2012-06-01

    ...[deg]51'18.70'' W (NAD 83). This safety zone will be enforced from 9:15 p.m. until 9:45 p.m. on May 27...[deg]51[min]18.70[sec] W (NAD 83). (2) Enforcement period. This safety zone will be enforced between 9...-AA00 Safety Zones: Catawba Island Club Fire Works, Catawba Island Club, Port Clinton, OH; Racing for...

  10. Criticality safety analysis of spent fuel storage for NPP Mochovce using MCNP5

    Farkas, G.; Hascik, J.; Lueley, J.; Vrban, B.; Petriska, M.; Slugen, V.; Urban, P.

    2011-01-01

    The paper presents results of nuclear criticality safety analysis of spent fuel storage for the first and second unit of NPP Mochovce. The spent fuel storage pool (compact and reserve grid) was modeled using the Monte Carlo code MCNP5. Conservative approach was applied and calculation of k eff values was performed for normal and various postulated emergency conditions in order to evaluate the final maximal k eff values. The requirement of current safety regulations to ensure 5% subcriticality was met except one especially conservative case. (Authors)

  11. Verification of criticality safety in on-site spent fuel storage systems

    Rasmussen, R.W.

    1989-01-01

    On February 15, 1984, Duke Power Company received approval for a two-region, burnup credit, spent fuel storage rack design at both Units 1 and 2 of the McGuire Nuclear Station. Duke also hopes to obtain approval by January of 1990 for a dry spent fuel storage system at the Oconee Nuclear Station, which will incorporate the use of burnup credit in the criticality analysis governing the design of the individual storage units. While experiences in burnup verification for criticality safety for their dry storage system at Oconee are in the future, the methods proposed for burnup verification will be similar to those currently used at the McGuire Nuclear Station in the two-region storage racks installed in both pools. In conclusion, the primary benefit of the McGuire rerack effort has obviously been the amount of storage expansion it provided. A total increase of about 2,000 storage cells was realized, 1,000 of which were the result of pursuing the two-region rather than the conventional poison rack design. Less impacting, but equally as important, however, has been the experience gained during the planning, installation, and operation of these storage racks. This experience should prove useful for future rerack efforts likely to occur at Duke's Catawba Nuclear Station as well as for the current dry storage effort underway for the Oconee Nuclear Station

  12. Safety of interim storage solutions of used nuclear fuel during extended term

    Shelton, C.; Bader, S.; Issard, H.; Arslan, M. [AREVA, 7135 Minstrel Way, Suite 300 Columbia, MD 21045 (United States)

    2013-07-01

    In 2013, the total amount of stored used nuclear fuel (UNF) in the world will reach 225,000 T HM. The UNF inventory in wet storage will take up over 80% of the available total spent fuel pool (SFP) capacity. Interim storage solutions are needed. They give flexibility to the nuclear operators and ensure that nuclear reactors continue to operate. However, we need to keep in mind that they are also an easy way to differ final decision and implementation of a UNF management approach (recycling or final disposal). In term of public perception, they can have a negative impact overtime as it may appear that nuclear industry may have significant issues to resolve. In countries lacking an integrated UNF management approach, the UNF are being discharged from the SFPs to interim storage (mostly to dry storage) at the same rate as UNF is being discharged from reactors, as the SFPs at the reactor sites are becoming full. This is now the case in USA, Taiwan, Switzerland, Spain, South Africa and Germany. For interim storage, AREVA has developed different solutions in order to allow the continued operation of reactors while meeting the current requirements of Safety Authorities: -) Dry storage canisters on pads, -) Dual-purpose casks (dry storage and transportation), -) Vault dry storage, and -) Centralized pool storage.

  13. IAEA'S International Working Group on Integrated Transport and Storage Safety case for Dual Purpose Casks

    Kumano, Yumiko; Varley, Kasturi; ); Droste, Bernhard; Wolff, Dietmar; Hirose, Makoto; Harvey, John; Reiche, Ingo; McConnell, Paul

    2014-01-01

    Spent nuclear fuel is generated from the operation of nuclear reactors and it is imperative that it is safely managed following its removal from reactor cores. Reactor pools are usually designed based on the assumption that the fuel will be removed after a short period of time either for reprocessing, disposal, or further storage. As a result of storing higher burn-up fuel, significantly increased time-frame till disposal solutions are prepared, and delays in decisions on strategies for spent fuel management, the volume of spent fuel discharged from reactors which needs to be managed and stored is on the increase. Consequently, additional storage capacity is needed following the initial storage in reactor pools. Options for additional storage include wet storage or dry storage in a dedicated facility or in storage casks. One of these options is the use of a Dual Purpose Cask (DPC), which is a specially designed cask for both storage and transport. The management of spent fuel using a DPC generally involves on-site and off-site transportation before and after storage. Most countries require package design approval for the DPC to be transported. In addition, it is required in many countries to have a licence for storage of the spent fuel in the DPC or a licence for a storage facility that contains DPCs. Therefore, demonstration of compliance of the DPC with national and international transport regulations as well as with the storage requirements is necessary. In order to address this increasing need among Member States, the IAEA established an international working group in 2010 to develop a guidance for integrating safety cases for both storage and transport in a holistic manner. The working group consists of experts from regulatory bodies, Technical Support Organizations, operators for both transportation and storage, and research institutes. This activity is planned to be completed by 2013. Currently, a technical report has been drafted and is expected to be

  14. Accord on “Fire and Building Safety in Bangladesh”: A Breakthrough Agreement?

    Zillur Rahman

    2014-03-01

    Full Text Available This discussion aims to review the emergence of the “Accord on Fire and Building Safety in Bangladesh” signed on May 13, 2013, and evaluate if it is an international agreement “breakthrough”. The Accord is signed not only by the global clothing brands and national garment unions but also by international trade union organizations, which is a new development. This raises a question: could this agreement set a new international negotiating precedence in industrial relations between transnational corporations and international trade union organizations? In Bangladesh, globalization has played an important role for booming garment industries. Yet, lack of workers’ rights, weak safety situations, and poor working conditions have continuously been reported. Local and international solidarity movements and garment workers’ welfare associations have been emphasizing workers’ rights and better and safer working environments in workplaces since the beginning of the 1990s. However, their voices were not highly considered even there were some initiatives. Following the ‘Rana Plaza’ garment factory building collapse in April 2013, one of the world’s worst industrial accidents, with more than 1,100 dead workers, some strong measures have been taken—one of these, signing the ‘Accord on Fire and Building Safety in Bangladesh’. This is a strong achievement of a long struggle to take collective action for improving the safety in garment factories in Bangladesh. Although the Accord is understood as a game changer or breakthrough in relation to national and international agreements, do we really know yet if it is a breakthrough or not when it comes to its implementation?

  15. Safety improvements made at the Loviisa nuclear power plant to reduce fire risks originating from the turbine generators

    Virolainen, T.; Marttila, J.; Aulamo, H.

    1998-01-01

    Comprehensive upgrading measures have been completed for the Loviisa Nuclear Power Plant (modified VVER440/V213). These were carried out from the start of the design phase and during operation to ensure safe plant shutdown in the event of a large turbine generator oil fire. These modifications were made mainly on a deterministic basis according to specific risk studies and fire analyses. As part of the probabilistic safety assessment, a fire risk analysis was made that confirmed the importance of these upgrading measures. In fact, they should be considered as design basis modifications for all VVER440 plants. (author)

  16. Cigeo storage project - Examination of the Safety options file. Meeting of the Experts Permanent Groups for wastes and for laboratories and plants on the 18-19 May 2017

    2017-01-01

    This document contains a report in two volumes and several appendices with documents issues by other bodies than the IRSN (notably the ASN). The two volumes report a study made on the request of the ASN regarding safety options for the Cigeo project of deep geological storage of nuclear wastes. The first volume proposes a description of the Cigeo project (site, storage architecture, parcels, Cigeo timescale, storage closure, processes implemented within the installations, Cigeo adaptability to inventory evolution, safety functions), addresses the waste parcel inventory (parcel inventory, reference radiological and chemical inventories, storage planning, reserve wastes, spent fuels), presents elements related to the site itself (geological context, natural resources, geo-dynamic characterisation, host rock, hydro-geology of aquifer layers), discusses the evolution of storage components (parcel behaviour after storage closure, evolution of steels, of concretes and of clayey materials). The second volume proposes a detailed overview of the safety approach for the different phases (exploitation, and after closure), proposes an assessment of safety during the exploitation phase (internal risks from nuclear origin, internal aggressions like fire, flooding or explosion, or related to parcel transport and handling, external aggressions like earthquakes, external flooding, and issues related to exploitation effluents and wastes), and proposes a safety assessment after closure (risk analysis for underground installations, and assessment of the global confinement capacity)

  17. Safety demonstration tests of postulated solvent fire accidents in extraction process of a fuel reprocessing plant, (2)

    Tukamoto, Michio; Takada, Junichi; Koike, Tadao; Nishio, Gunji; Uno, Seiichiro; Kamoshida, Atsusi; Watanabe, Hironori; Hashimoto, Kazuichiro; Kitani, Susumu.

    1992-03-01

    Demonstration tests of hypothetical solvent fire in an extraction process of the reprocessing plant were carried out from 1984 to 1985 in JAERI, focusing on the confinement of radioactive materials during the fire by a large-scale fire facility (FFF) to evaluate the safety of air-ventilation system in the plant. Fire data from the demonstration test were obtained by focusing on fire behavior at cells and ducts in the ventilation system, smoke generation during the fire, transport and deposition of smoke containing simulated radioactive species in the ventilation system, confinement of radioactive materials, and integrity of HEPA filters by using the FFF simulating an air-ventilation system of the reference reprocessing plant in Japan. The present report is published in a series of the report Phase I (JAERI-M 91-145) of the demonstration test. Test results in the report will be used for the verification of a computer code FACE to evaluate the safety of postulated fire accidents in the reprocessing plant. (author)

  18. Suggestion on the safety classification of spent fuel dry storage in China’s pressurized water reactor nuclear power plant

    Liu, Ting; Qu, Yunhuan; Meng, De; Zhang, Qiaoer; Lu, Xinhua

    2018-01-01

    China’s spent fuel storage in the pressurized water reactors(PWR) is stored with wet storage way. With the rapid development of nuclear power industry, China’s NPPs(NPPs) will not be able to meet the problem of the production of spent fuel. Currently the world’s major nuclear power countries use dry storage as a way of spent fuel storage, so in recent years, China study on additional spent fuel dry storage system mainly. Part of the PWR NPP is ready to apply for additional spent fuel dry storage system. It also need to safety classificate to spent fuel dry storage facilities in PWR, but there is no standard for safety classification of spent fuel dry storage facilities in China. Because the storage facilities of the spent fuel dry storage are not part of the NPP, the classification standard of China’s NPPs is not applicable. This paper proposes the safety classification suggestion of the spent fuel dry storage for China’s PWR NPP, through to the study on China’s safety classification principles of PWR NPP in “Classification for the items of pressurized water reactor nuclear power plants (GB/T 17569-2013)”, and safety classification about spent fuel dry storage system in NUREG/CR - 6407 in the United States.

  19. Fire testing of 55 gallon metal waste drums for dry waste storage

    Hasegawa, H.K.; Staggs, K.J.; Doughty, S.M.

    1993-07-01

    The primary goal of this test program was to conduct a series of fire test to provide information on the fire performance of 55 gallon metal waste drums used for solid waste disposal at Department Of Energy (DOE) facilities. This program was limited in focus to three different types of 55 gallon drums, one radiant heat source, and one specific fire size. The initial test was a single empty 55 gallon drum exposed to a standard ASTME-119 time temperature curve for over 10 minutes. The full scale tests involved metal drums exposed to a 6' diameter flammable liquid fire for a prescribed period of time. The drums contained simulated dry waste materials of primarily class A combustibles. The test results showed that a conventional 55 gallon drum with a 1in. bung would blow its lid consistently

  20. Changes in Fire-Derived Soil Black Carbon Storage in a Sub-humid Woodland

    White, J. D.; Yao, J.; Murray, D. B.; Hockaday, W. C.

    2014-12-01

    Fire-derived black carbon (BC) in soil, including charcoal, represents a potentially important fraction of terrestrial carbon cycling due to its presumed long persistence in soil. Interpretation of site BC retention is important for assessing feedbacks to ecosystem processes including nutrient and water cycling. However, interaction between vegetation disturbance, BC formation, and off site transport may exist that complicate interpretation of BC addition to soils from wildfire or prescribed burns directly. To investigate the relationship between disturbance and site retention on soil BC, we determined BC concentrations for a woodland in central Texas, USA, from study plots in hilly terrain with a fire scar dendrochronology spanning 100 years. BC values were determined from 13C nuclear magnetic resonance (NMR) spectroscopy. Estimated values showed mean BC concentration of 2.73 ± 3.06 g BC kg-1 (0.91 ± 0.51 kg BC m-2) for sites with fire occurrence within the last 40 years compared with BC values of1.21 ± 1.70 g BC kg-1 soil (0.18 ± 0.14 kg BC m-2) for sites with fire 40 - 100 years ago. Sites with no tree ring evidence of fire during the last 100 years had the lowest mean soil BC concentration of 0.05 ± 0.11 g BC kg-1 (0.02 ± 0.03 kg BC m-2). Molecular proxies of stability (lignin/N) and decomposition (Alkyl C/O-Alky C) showed no differences across the sites, indicating that low potential for BC mineralization. Modeled soil erosion and time since fire from fire scar data showed that soil BC concentrations were inversely correlated. A modified the ecosystem process model, Biome-BGC, was also used simulate the effects of fire disturbance with different severities and seasonality on C cycling related to the BC production, effect on soil water availability, and off-site transport. Results showed that BC impacts on ecosystem processes, including net ecosystem exchange and leaf area development, were predominantly related to fire frequency. Site BC loss rates were

  1. Evaluation of the Ventilation and Air Cleaning System Design Concepts for Safety Requirements during Fire Conditions in Nuclear Applications

    Rashad, S.; El-Fawal, M.; Kandil, M.

    2013-01-01

    The ventilation and air cleaning system in the nuclear or radiological installations is one of the essential nuclear safety concerns. It is responsible for confining the radioactive materials involved behind suitable barriers during normal and abnormal conditions. It must be designed to prevent the release of harmful products (radioactive gases, or airborne radioactive materials) from the system or facility, impacting the public or workers, and doing environmental damage. There are two important safety functions common to all ventilation and air cleaning system in nuclear facilities. They are: a) the requirements to maintain the pressure of the ventilated volume below that of surrounding, relatively non-active areas, in order to inhibit the spread of contamination during normal and abnormal conditions, and b) the need to treat the ventilated gas so as to minimize the release of any radioactive or toxic materials. Keeping the two important safety functions is achieved by applying the fire protection for the ventilation system to achieve safety and adequate protection in nuclear applications facilities during fire and accidental criticality conditions.The main purpose of this research is to assist ventilation engineers and experts in nuclear installations for safe operation and maintaining ventilation and air cleaning system during fire accident in nuclear facilities. The research focuses on fire prevention and protection of the ventilation systems in nuclear facilities. High-Efficiency particulate air (HEPA) filters are extremely susceptible to damage when exposed to the effects of fire, smoke, and water; it is the intent of this research to provide the designer with the experience gained over the years from hard lessons learned in protecting HEPA filters from fire. It describes briefly and evaluates the design safety features, constituents and working conditions of ventilation and air cleaning system in nuclear and radioactive industry.This paper provides and

  2. Young children's perceptions of fire-safety messages: do framing and parental mediation matter?

    Borzekowski, Dina; Clearfield, Elizabeth; Rimal, Rajiv; Gielen, Andrea

    2014-01-01

    Media can deliver health and safety messages promoting child health and injury prevention. This study examined the effects of message framing and parental mediation on children's perceptions of fire-safety messages. Using a 2 × 3 randomized experimental design, this study considered both message framing (gain or loss) and parental mediation (no mediation/control, unscripted, or scripted) with 320 children who were 4 and 5 years of age. Children saw two messages (burn and smoke inhalation) embedded in a cartoon. Afterward, researchers assessed children's recall, understanding, and perceptions of self-efficacy and social norms. Children were more likely to recall the safety messages if they were older (burn: adjusted odds ration [AOR] = 2.74 and smoke: AOR = 2.58), and could recall the smoke inhalation message if they had unscripted mediation (AOR = 3.16). Message understanding was poor, with only about 50% of children choosing a correct behavior in a similar scenario. For the burn message, correct understanding was associated with gain-framing and scripted mediation (AOR = 3.22 and 5.77, respectively). Only the scripted mediation group was significantly associated with an increase in perceived social norms (burn: coefficient =.37 and smoke: coefficient =.55; P video-based messages to teach children safety behaviors needs to be enhanced.

  3. Management of fire and industrial safety - challenges during commissioning of a NPP

    Maiti, Subhaschandra; Mohan, Nalini; Ghadge, S.G.; Bajaj, S.S.

    2006-01-01

    Construction and commissioning period of NPP are reduced world over drastically by stringent schedule for financial and economic reasons. For meeting the schedule, commissioning of components and systems are started immediate after installation, while construction activities are continued in parallel at the same place. Parallel activities' and 'Time Constraint' have brought new challenges to 'Management of Fire and Industrial Safely' during commissioning. An innovative approach was used during such phase of commissioning of TAPP-3 and 4. This paper outlines challenges encountered during this phase and special approach and measures used to meet those challenges. This paper also outlines problems encountered during implementation of these measures and subsequent change in approach to ensure smooth and safe execution of activities. Primarily, challenges were conflicting requirements by various agencies to carryout commissioning in parallel with construction activities concurrently. Main challenges were related to fall hazard, chemical hazard, fire hazard, electrical safety, work in confined space, housekeeping problem. Moreover it was within exclusion zone of another operating plant, which added one more dimension to those challenges. Conventional Safely management approach was little short to resolve these challenges. Such challenges were envisaged; analyzed and innovative measures were arrived at. Along with conventional safely analysis like Job Safely or Hazard Analysis (JSA or JHA), Accident Analysis, Accident Trend Analysis, Fire Hazard Analysis (FHA), innovative method like 'Area-Job- Hazard Charting' and 'Ratio Analysis' were used to understand activity dependent time varying hazard scenarios. Based on this analysis, decision were taken to change various existing elements of safely management like safety organizations; standard operating procedures (SOP); emergency operating procedures (EOP); resource allocation, planning and scheduling; safely training; safely

  4. Extended storage for radioactive wastes: relevant aspects related to the safety

    Castillo, Reinaldo G.; Peralta V, José L.P.; Estevez, Gema G. F.

    2013-01-01

    The safe management of radioactive waste is an issue of great relevance globally linked to the issue of the peaceful use of nuclear energy. Among the steps in the management of this waste, the safe storage is one of the most important. Given the high costs and uncertainties existing among other aspects of the variants of disposal of radioactive waste, the prolonged storage of these wastes for periods exceeding 50 years is an option that different countries more and more value. One of the fundamental problems to take into account is the safety of the stores, so in this work are evaluated different safety components associated with these facilities through a safety analysis methodology. Elements such as human intrusion, the construction site, the design of the facility, among others are identified as some of the key aspects to take into account when evaluating the safety of these types of facilities. Periods of activities planned for a long-term storage of radioactive waste exceed, in general, the useful life of existing storage facilities. This work identified new challenges to overcome in order to meet the requirements for the achievement of a safe management of radioactive waste without negative impacts on the environment and man

  5. A study on safety analysis methodology in spent fuel dry storage facility

    Che, M. S.; Ryu, J. H.; Kang, K. M.; Cho, N. C.; Kim, M. S. [Hanyang Univ., Seoul (Korea, Republic of)

    2004-02-15

    Collection and review of the domestic and foreign technology related to spent fuel dry storage facility. Analysis of a reference system. Establishment of a framework for criticality safety analysis. Review of accident analysis methodology. Establishment of accident scenarios. Establishment of scenario analysis methodology.

  6. Classification of transportation packaging and dry spent fuel storage system components according to importance to safety

    McConnell, J.W., Jr; Ayers, A.L. Jr; Tyacke, M.J.

    1996-02-01

    This report provides a graded approach for classification of components used in transportation packaging and dry spent fuel storage systems. This approach provides a method for identifying, the classification of components according to importance to safety within transportation packagings and dry spent fuel storage systems. Record retention requirements are discussed to identify the documentation necessary to validate that the individual components were fabricated in accordance with their assigned classification. A review of the existing regulations pertaining to transportation packagings and dry storage systems was performed to identify current requirements The general types of transportation packagings and dry storage systems were identified. Discussions were held with suppliers and fabricators of packagings and storage systems to determine current practices. The methodology used in this report is based on Regulatory Guide 7.10, Establishing Quality Assurance Programs for Packaging Used in the Transport of Radioactive Material. This report also includes a list of generic components for each of the general types of transportation packagings and spent fuel storage systems. The safety importance of each component is discussed, and a classification category is assigned

  7. A study of thermal, structural and shielding safety analysis for dry storage of spent nuclear fuel

    Shin, S. H. [Kyungpook Nationl Univ., Daegu (Korea, Republic of)

    1997-03-15

    As a replaced method for MRS, the dry storage has been intensively developed by the advanced countries of nuclear power technology. Currently, the domestic technology for the dry storage is also under development. In the present study, the developed technical standards for USNRC and its operation are summarized. Futhermore, the SAR for VECTRA's NUHOMES satisfied with DOE and NRC's requirements is inversely analyzed and combined with both USNRC's regulatory guide and LLNL's SARS. In the safety analysis of a dry storage, the principal design criteria which identifies the structural and mechanical safety criteria is investigated. Based on the design criteria, hypothetical accident analysis as well as off-normal operation analysis are investigated.

  8. IoT-Based Intelligent Modeling of Smart Home Environment for Fire Prevention and Safety

    Faisal Saeed; Anand Paul; Abdul Rehman; Won Hwa Hong; Hyuncheol Seo

    2018-01-01

    Fires usually occur in homes because of carelessness and changes in environmental conditions. They cause threats to the residential community and may result in human death and property damage. Consequently, house fires must be detected early to prevent these types of threats. The immediate notification of a fire is the most critical issue in domestic fire detection systems. Fire detection systems using wireless sensor networks sometimes do not detect a fire as a consequence of sensor failure....

  9. Canister storage building (CSB) safety analysis report phase 3:safety analysis documentation supporting CSB construction

    Garvin, L.J.

    1996-01-01

    The purpose of this report is to provide an evaluation of the Canister Storage Building (CSB) design criteria, the design's compliance with the applicable criteria, and the basis for authorization to proceed with construction of the CSB

  10. Assessment of Application Example for a Sodium Fire Extinguishing Facility using Safety Control of Dangerous Substances Act

    Jung, Minhwan; Jeong, Ji-Young; Kim, Jongman

    2014-01-01

    Sodium is under regulation of four kinds of laws including the Safety Control of Dangerous Substances Act and it is under categorized as Class 3(pyrophoric material, water-prohibiting substance). To obtain a license for a sodium experiment facility, the codes and regulations must be satisfied in the Safety Control of Dangerous Substance Act. However, there are some parts that need to be discussed in related regulations in the Safety Control of Dangerous Substance Act because there are differences with the actual features of sodium. To apply for an actual sodium facility, it is necessary to give a supplementary explanation regarding the regulations. The objective of this study is to assess the application example of a sodium experiment facility using the above mentioned laws and to propose the necessity of an amendment for conventional laws in regard to fire extinguishing systems and agents. In this work, an application example of a sodium experiment facility using the Safety Control of Dangerous Substances Act, and the necessity of amending the existing laws in regard to fire extinguishing systems including the agent used, was assessed. The safest standard was applied for cases in which the consideration of a sodium fire is not mentioned in conventional regulations. For the construction of the PGSFR (Prototype Gen-IV Sodium-cooled Fast Reactor), the described regulations in this work should be reviewed and improved carefully by the fire safety regulatory body

  11. Information report on the nuclear safety and radiation protection of the Aube storage Centre - 2012

    2013-07-01

    This report first present the site of the Aube Storage Centre (CSA), its storage areas, its buildings and equipment, describes the water treatment process, proposes some exploitation data for 2012 (deliveries, storage, compacting), and indicates highlights and works performed in 2012. The next part reviews measures related to nuclear safety: recall of safety principles and objectives, technical arrangements to meet safety objectives, inspections by the ASN, quality audits. The third part reviews measures related to safety and radiation protection: principles for radiation protection, staff dosimetry practices and results, personnel safety, works performed in 2012. The fourth part addresses incidents and accidents (none occurred in 2012) and other minor events classified according to the INES scale. The fifth part addresses the control of the environment and the releases by the centre: measurement locations, measurement results (in the atmosphere, in rivers, in underground waters, radiological control, control of ecosystems, assessment of the radiological impact), physical-chemical control of a local river, actions undertaken for the protection of the environment, highlights for 2012. The next chapter addresses the management of the various wastes produced by the Centre (radioactive wastes, conventional wastes) and the last part reports actions regarding information and transparency. Recommendations of the CHSCT are reported

  12. Computer program for storage of historical and routine safety data related to radiologically controlled facilities

    Marsh, D.A.; Hall, C.J.

    1984-01-01

    A method for tracking and quick retrieval of radiological status of radiation and industrial safety systems in an active or inactive facility has been developed. The system uses a mini computer, a graphics plotter, and mass storage devices. Software has been developed which allows input and storage of architectural details, radiological conditions such as exposure rates, current location of safety systems, and routine and historical information on exposure and contamination levels. A blue print size digitizer is used for input. The computer program retains facility floor plans in three dimensional arrays. The software accesses an eight pen color plotter for output. The plotter generates color plots of the floor plans and safety systems on 8 1/2 x 11 or 20 x 30 paper or on overhead transparencies for reports and presentations

  13. Safety and optimization aspects of radioactive waste long-term storage at the ''Vector'' site

    Tokarevs'kij, O.V.; Kondrat'jev, S.M.; Aleksjejeva, Z.M.; Ribalka, N.V.

    2015-01-01

    The paper analyzes links between the final disposal option and needs for long-term storage of radioactive waste taking into proposals on possible changes in radwaste classification as regards disposal. It considers the conceptual approach to design facilities for long-term storage of long-lived radioactive waste at the Vector site and approaches to apply requirements of regulatory documents, radiation safety principles and criteria for long-term storage of radwaste and safety assessment.

  14. Safety issue resolution strategy plan for inactive miscellaneous underground storage tanks

    Wang, O.S.; Powers, T.B.

    1994-09-01

    The purpose of this strategy plan is to identify, confirm, and resolve safely issues associated with inactive miscellaneous underground storage tanks (MUSTs) using a risk-based priority approach. Assumptions and processes to assess potential risks and operational concerns are documented in this report. Safety issue priorities are ranked based on a number of considerations including risk ranking and cost effectiveness. This plan specifies work scope and recommends schedules for activities related to resolving safety issues, such as collecting historical data, searching for authorization documents, performing Unreviewed Safety Question (USQ) screening and evaluation, identifying safety issues, imposing operational controls and monitoring, characterizing waste contents, mitigating and resolving safety issues, and fulfilling other remediation requirements consistent with the overall Tank Waste Remediation System strategy. Recommendations for characterization and remediation are also recommended according to the order of importance and practical programmatic consideration

  15. Safety analysis report for the Mixed Waste Storage Facility and portable storage units at the Idaho National Engineering Laboratory. Revision 4

    Peatross, R.

    1997-01-01

    This revision contains Section 2 only which gives a description of the Mixed Waste Storage Facility (MWSF) and its operations. Described are the facility location, services and utilities, process description and operation, and safety support systems. The MWSF serves as a storage and repackaging facility for low-level mixed waste

  16. 77 FR 4897 - Safety Zone; M/V Del Monte Live-Fire Gun Exercise, James River, Isle of Wight, VA

    2012-02-01

    ...-AA00 Safety Zone; M/V Del Monte Live-Fire Gun Exercise, James River, Isle of Wight, VA AGENCY: Coast... provide for the safety of life on navigable waters during the live-fire gun exercises on the M/V Del Monte... associated with the live-fire gun exercise. DATES: This rule is effective in the CFR on February 1, 2012...

  17. 76 FR 31848 - Safety Zone; M/V Del Monte Live-Fire Gun Exercise, James River, Isle of Wight, Virginia

    2011-06-02

    ...-AA00 Safety Zone; M/V Del Monte Live-Fire Gun Exercise, James River, Isle of Wight, Virginia AGENCY... provide for the safety of life on navigable waters during the live-fire gun exercises on the M/V Del Monte... associated with the live-fire gun exercise. DATES: This rule will be effective from 11 a.m. June 6, 2011...

  18. Review and investigations of oscillatory flow behaviour of a horizontal ceiling opening for nuclear containment and fire safety analysis

    Sharma, P.K.; Singh, R.K.; Ghosh, A.K. [Bhabha Atomic Research Centre, Trombay, Mumbai (India). Reactor Safety Div.

    2011-05-15

    In the thermal hydraulics codes developed for fire safety analysis and for containment thermal hydraulic analysis, junctions in the multi-compartment geometries is often modeled as uni-directional junctions. However, ceiling junctions are known to depict unstable/oscillatory bi-directional flow behavior. Detailed investigations have been carried out to understand the unstable flow behaviour of a junction by analyzing an earlier reported experiment and its subsequent two dimensional numerical RANS based study of fire in an enclosure. The authors attempt more realistic and desired three dimensional and inherently transient large eddy simulations using a computer code Fire Dynamics Simulator (FDS). The paper presents the details of the analysis, the results obtained and further studies required to be conducted so that the findings can be applied to the fire/containment thermal hydraulics analysis codes successfully. (orig.)

  19. Novel PEPA-functionalized graphene oxide for fire safety enhancement of polypropylene

    Xu, Jia You; Liu, Jie; Li, Kai Dan; Miao, Lei; Tanemura, Sakae

    2015-01-01

    Polypropylene (PP) is a general-purpose plastic, but some applications are constrained by its high flammability. Thus, flame retardant PP is urgently demanded. In this article, intumescent flame retardant PP (IFRPP) composites with enhanced fire safety were prepared using 1-oxo-4-hydroxymethyl-2,6,7-trioxa-1-phosphabicyclo [2.2.2] octane (PEPA) functionalized graphene oxide (PGO) as synergist. The PGO was prepared through a mild chemical reaction by the covalent attachment of a caged-structure organic compound, PEPA, onto GO nanosheets using toluene diisocynate (TDI) as the intermediary agent. The novel PEPA-functionalized graphene oxide not only improves the heat resistance of GO but also converts GO and PEPA from hydrophobic to hydrophilic materials, which leads to even distribution in PP. In our case, 7 wt% addition of PGO as one of the fillers for IFRPP composites significantly reduces its inflammability and fire hazards when compared with PEPA, by the improvement of first release rate peak (PHRR), total heat release, first smoke release rate peak (PSRR) and total smoke release, suggesting its great potential as the IFR synergist in industry. The reason is mainly attributed to the barrier effect of the unburned graphene sheets, which protects by the decomposition products of PEPA and TDI, promotes the formation of graphitized carbon and inhibits the heat and gas release. (paper)

  20. Novel PEPA-functionalized graphene oxide for fire safety enhancement of polypropylene

    Xu, Jia You; Liu, Jie; Li, Kai Dan; Tanemura, Sakae

    2015-01-01

    Polypropylene (PP) is a general-purpose plastic, but some applications are constrained by its high flammability. Thus, flame retardant PP is urgently demanded. In this article, intumescent flame retardant PP (IFRPP) composites with enhanced fire safety were prepared using 1-oxo-4-hydroxymethyl-2,6,7-trioxa-1-phosphabicyclo [2.2.2] octane (PEPA) functionalized graphene oxide (PGO) as synergist. The PGO was prepared through a mild chemical reaction by the covalent attachment of a caged-structure organic compound, PEPA, onto GO nanosheets using toluene diisocynate (TDI) as the intermediary agent. The novel PEPA-functionalized graphene oxide not only improves the heat resistance of GO but also converts GO and PEPA from hydrophobic to hydrophilic materials, which leads to even distribution in PP. In our case, 7 wt% addition of PGO as one of the fillers for IFRPP composites significantly reduces its inflammability and fire hazards when compared with PEPA, by the improvement of first release rate peak (PHRR), total heat release, first smoke release rate peak (PSRR) and total smoke release, suggesting its great potential as the IFR synergist in industry. The reason is mainly attributed to the barrier effect of the unburned graphene sheets, which protects by the decomposition products of PEPA and TDI, promotes the formation of graphitized carbon and inhibits the heat and gas release. PMID:27877775

  1. The Persuasive Power of Virtual Reality: Effects of Simulated Human Distress on Attitudes towards Fire Safety

    Chittaro, Luca; Zangrando, Nicola

    Although virtual reality (VR) is a powerful simulation tool that can allow users to experience the effects of their actions in vivid and memorable ways, explorations of VR as a persuasive technology are rare. In this paper, we focus on different ways of providing negative feedback for persuasive purposes through simulated experiences in VR. The persuasive goal we consider concerns awareness of personal fire safety issues and the experiment we describe focuses on attitudes towards smoke in evacuating buildings. We test two techniques: the first technique simulates the damaging effects of smoke on the user through a visualization that should not evoke strong emotions, while the second is aimed at partially reproducing the anxiety of an emergency situation. The results of the study show that the second technique is able to increase user's anxiety as well as producing better results in attitude change.

  2. Fire safety aspects in cultural heritage : a case study in historical Delft

    Öhlin Lostetter, S.M.; Breunese, A.J.

    2005-01-01

    Fire is an important threat to cultural heritage. Therefore 12 fire laboratories and consultants across the EU have joined together for the European Thematic-Network Fire Risk Evaluation to European Cultural Heritage (Fire-Tech). The final goal of this thematic network was to develop a decision

  3. Passive safety device and internal short tested method for energy storage cells and systems

    Keyser, Matthew; Darcy, Eric; Long, Dirk; Pesaran, Ahmad

    2015-09-22

    A passive safety device for an energy storage cell for positioning between two electrically conductive layers of the energy storage cell. The safety device also comprising a separator and a non-conductive layer. A first electrically conductive material is provided on the non-conductive layer. A first opening is formed through the separator between the first electrically conductive material and one of the electrically conductive layers of the energy storage device. A second electrically conductive material is provided adjacent the first electrically conductive material on the non-conductive layer, wherein a space is formed on the non-conductive layer between the first and second electrically conductive materials. A second opening is formed through the non-conductive layer between the second electrically conductive material and another of the electrically conductive layers of the energy storage device. The first and second electrically conductive materials combine and exit at least partially through the first and second openings to connect the two electrically conductive layers of the energy storage device at a predetermined temperature.

  4. Safety climate in the US federal wildland fire management community: influences of organizational, environmental, group, and individual characteristics

    Anne E. Black; Brooke Baldauf McBride

    2013-01-01

    This study examined the effects of organisational, environmental, group and individual characteristics on five components of safety climate (High Reliability Organising Practices, Leadership, Group Culture, Learning Orientation and Mission Clarity) in the US federal wildland fire management community. Of particular interest were differences between perceptions based on...

  5. Safety climate in the federal fire management community: Influences of organizational, environmental, group, and individual characteristics (Abstract)

    Brooke Baldauf McBride; Anne E. Black

    2012-01-01

    This study examined the effects of organizational, environmental, group and individual characteristics on five components of safety climate in the US federal fire management community (HRO Practices, Leadership, Group Culture, Learning Orientation and Mission Clarity). Multiple analyses of variance revealed that all types of characteristics had a significant effect on...

  6. A Fire Safety Certification System for Board and Care Operators and Staff. SBIR Phase II: Final Report.

    Walker, Bonnie L.

    This report describes Phase II of a project which developed a system for delivering fire safety training to board and care providers who serve adults with developmental disabilities. Phase II focused on developing and pilot testing a "train the trainers" workshop for instructors and field testing the provider's workshop. Evaluation of…

  7. A Fire Safety Certification System for Board and Care Operators and Staff. SBIR Phase I: Final Report.

    Walker, Bonnie L.

    This report describes the development and pilot testing of a fire safety certification system for board and care operators and staff who serve clients with developmental disabilities. During Phase 1, training materials were developed, including a trainer's manual, a participant's coursebook a videotape, an audiotape, and a pre-/post test which was…

  8. Final safety-analysis report for the Fifth Calcined Solids Storage Facility

    1982-01-01

    Radioactive aqueous wastes generated by the solvent extraction of uranium from expended fuels at ICPP will be calcined in the New Waste Calcining Facility (NWCF). The calcined solids are pneumatically transferred to stainless steel bins enclosed in concrete vaults for interim storage of up to 500 years. The Fifth Calcined Solids Storage Facility (CSSF) provides 1000 m 3 of storage and consists of seven annular stainless steel bins inside a reinforced concrete vault set on bedrock. Storage of calcined solids is essentially a passive operation with very little opportunity for release of radionuclides and with no potential for criticality. There will be no potential for fire or explosion. Shielding has been designed to assure that the radiation levels at the vault exterior surfaces will be limited to less than 0.5 mRem/h. A sump in the vault floor will collect any in-leakage that may occur. Any water that collects in the sump will be sampled then removed with the sump jet. There will be an extremely small chance of release of radioactive particulates into the atmosphere as a result of a bin leak. The Design Basis Accident (DBA) postulates the spill of solids from an eroded fill line into the vault coupled with a failure of the vault cooling air radiation monitor. For the DBA, the maximum calculated radiation dose to an exposed individual near the site boundary is less than 1.2 μRem to the bone and lung

  9. Safety research activities for Japanese regulations of spent fuel interim storage facilities

    NONE

    2013-08-15

    Japan Nuclear Energy Safety Organization (JNES) carries out (a) preparation of technical documents, (b) technical evaluations of standards (prepared by academic societies), etc. and (c) other R and D activities, to support Nuclear Regulation Authority (NRA: which controls the regulations for Spent Fuel Interim Storage Facilities). In 2012 fiscal year, JNES carried out dynamic test of spent fuel to examine the integrity of spent fuel under cask drop accidents, and preparation for PWR spent fuel storage test to prove long term integrity of spent fuel and cask itself. Some of these tests will be also carried out in 2013 fiscal year and after. (author)

  10. Safety aspects in the dry storage of spent nuclear fuel in long term operation

    Nodarim, Claudir J.; Silva, Viviane B. da; Fontes, Gladson S. [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil); Saldanha, Pedro L.C., E-mail: claudirnodari@gmail.com, E-mail: vivisborges@gmail.com, E-mail: gsfontes@hotmail.com, E-mail: Saldanha@cnen.gov.br [Comissão Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    The purpose of the present paper is to discuss the safety assessment of the Dry Storage Unit (DSU), taking into account the long term operation and the operational experience already evidenced in similar facilities. In this sense, the RIDM (Risk-Informed Decision-Making) concept will be adopted for the regulatory decision-making process. Potential technical issues associated with the aging of materials from the dry storage unit will be considered. The work will be done using the rules and requirements of 10 CFR Part 72 and the U.S. NRC (United States Nuclear Regulatory Commission) regulatory guides. (author)

  11. New fire hazard in the company. Lithium batteries and lithium accumulators; Neue Brandgefahr im Betrieb. Lithiumbatterien und -akkumulatoren

    Lambotte, Stephan [Hochschule Furtwangen (Germany). Security and Safety Engineering

    2012-09-15

    Almost every fire prevention officer and each firefighter knows metal fires from demonstration tests as part of his training: gleaming bright light, high temperatures and spectacular reactions with water stay memorable to everyone present in these experiments. Everyone learns, that light metal fires practically can not be extinguished with water. On the contrary, the reaction with water induces a significant spread of fire. It is therefore understandable that fire safety officers are insecure when lithium based energy storage devices are used in companies. From this perspective, the author of the contribution under consideration report on the dangerousness of energy storage devices in the event of a fire.

  12. Assessment of enriched uranium storage safety issues at the Oak Ridge Y-12 Plant

    NONE

    1996-08-01

    This document is an assessment of the technical safety issues pertaining to the storage of EU at the Oak Ridge Y-12 Plant. The purpose of the assessment is to serve as the basis for defining the technical standards for storage of EU at Y-12. A formal assessment of the Y-12 materials acceptance criteria for EU is currently being conducted by a task force cochaired by B. G. Eddy of DOE Oak Ridge Operations and S. 0. Cox of Y-12 Defense Programs. The mission of this technical assessment for storage is obviously dependent on results of the acceptance assessment. Clearly, the two efforts require coordination to avoid inconsistencies. In addition, both these Assessments must be consistent with the Environmental Assessment for EU storage at Y-12.1 Both the Storage Assessment and the Criteria for Acceptance must take cognizance of the fact that a portion of the EU to be submitted for storage in the future is expected to be derived from foreign sources and to include previously irradiated uranium containing significant levels of transuranics, radioactive daughter products, and unstable uranium isotopes that do not occur in the EU stream of the DOE weapons complex. National security considerations may dictate that these materials be accepted despite the fact that they fail to conform to the Acceptance Criteria. This document will attempt to address the complexities inherent in this situation.

  13. Assessment of enriched uranium storage safety issues at the Oak Ridge Y-12 Plant

    1996-08-01

    This document is an assessment of the technical safety issues pertaining to the storage of EU at the Oak Ridge Y-12 Plant. The purpose of the assessment is to serve as the basis for defining the technical standards for storage of EU at Y-12. A formal assessment of the Y-12 materials acceptance criteria for EU is currently being conducted by a task force cochaired by B. G. Eddy of DOE Oak Ridge Operations and S. 0. Cox of Y-12 Defense Programs. The mission of this technical assessment for storage is obviously dependent on results of the acceptance assessment. Clearly, the two efforts require coordination to avoid inconsistencies. In addition, both these Assessments must be consistent with the Environmental Assessment for EU storage at Y-12.1 Both the Storage Assessment and the Criteria for Acceptance must take cognizance of the fact that a portion of the EU to be submitted for storage in the future is expected to be derived from foreign sources and to include previously irradiated uranium containing significant levels of transuranics, radioactive daughter products, and unstable uranium isotopes that do not occur in the EU stream of the DOE weapons complex. National security considerations may dictate that these materials be accepted despite the fact that they fail to conform to the Acceptance Criteria. This document will attempt to address the complexities inherent in this situation

  14. Final Safety Analysis Document for Building 693 Chemical Waste Storage Building at Lawrence Livermore National Laboratory

    Salazar, R.J.; Lane, S.

    1992-02-01

    This Safety Analysis Document (SAD) for the Lawrence Livermore National Laboratory (LLNL) Building 693, Chemical Waste Storage Building (desipated as Building 693 Container Storage Unit in the Laboratory's RCRA Part B permit application), provides the necessary information and analyses to conclude that Building 693 can be operated at low risk without unduly endangering the safety of the building operating personnel or adversely affecting the public or the environment. This Building 693 SAD consists of eight sections and supporting appendices. Section 1 presents a summary of the facility designs and operations and Section 2 summarizes the safety analysis method and results. Section 3 describes the site, the facility desip, operations and management structure. Sections 4 and 5 present the safety analysis and operational safety requirements (OSRs). Section 6 reviews Hazardous Waste Management's (HWM) Quality Assurance (QA) program. Section 7 lists the references and background material used in the preparation of this report Section 8 lists acronyms, abbreviations and symbols. Appendices contain supporting analyses, definitions, and descriptions that are referenced in the body of this report

  15. Manche storage Centre. Information report on nuclear safety and radiation protection 2015

    2016-01-01

    After a presentation of the Manche Storage Centre (CSM), the first French center of surface storage of low- and intermediate-level radioactive wastes, of its history, its buildings and activities, of the multi-layer cover, of the water management system (installation, controls, sampling), this report then describes the measures related to nuclear safety, the management of conventional and nuclear wastes produced by the Centre, the other impacts, the control, maintenance and follow-up of installations, the radiation protection and security of the center, the incidents and accidents that occurred at the facility, and the public information and communication actions. Recommendations of the Health and safety Committee (CHSCT) are reported at the end

  16. Safety Test Report for the PWR S/F Dry Storage System

    Seo, K. S.; Lee, J. H.; Koo, K. H.; Lee, J. C.; Choi, W. S.; Bang, K. S.; Park, H. Y.; Jang, S. Y

    2008-10-15

    This is contract report conducted by KAERI under the contract with NETEC for safety test for the PWR S/F dry storage system. Leak Test was performed after drop test and turn-over test, the measured leakage rate was lower than allowable leakage rate. It is revealed that the containment integrity of the dry storage system is maintained. In the seismic test, the moving of the model was measured at SRTH seismic response of 0.4 g and 0.8 g. Therefore the seismic test results can be used fully to the test data for verification of the seismic analysis. In the thermal test, the direction of the inlet and outlet of the air has no effect on the heat transfer performance. The passive heat removal system of the horizontal storage module was designed well.

  17. Safety of parsley intended for processing depending on the cultivation technology and storage

    Pobereżny Jarosław

    2016-09-01

    Full Text Available The factors that affect the value of parsley for consumption include its taste, flavour and dietary utility (vitamins C and E, β-carotene, potassium, calcium, phosphorus and iron, raw fibre, proteins as well as the content of hazardous substances, especially nitrogen compounds. A study was carried out in 2013–2015 to determine the effect of the cultivation technology and storage on the safety of parsley intended for processing. The study material was taken from an experiment where the following fertilisers were applied to the ground: nitrogen (0, 40, 80, 120 kg N∙ha−1 and magnesium (0; 30 kg Mg∙ha−1. Parsley roots were stored for six months in a storage room at +1°C and RH 95%. The content of nitrates (V and (III was determined by the ion selective method immediately after the harvest and after storage in parsley roots.

  18. Study on uncertainty evaluation system for the safety evaluation of interim spent fuel storage facility

    Kim, Myung Hyeon; Shin, Myeong Won; Rhy, Seok Jin; Cho, Dong Keon; Park, Dong Hwan [Kyunghee Univ., Seoul (Korea, Republic of); Cheong, Beom Jin [Minstry of Science and Technology, Gwacheon (Korea, Republic of)

    1998-03-15

    The main objective os to develop a technical standards for the facility operation of the interm, spent fuel storage facility and to develop a draft for the technical criteria to be legislated. The another objective os to define a uncertainty evaluation system for burn up credit application in criticality analysis and to investigate an applicability of this topic for future regulatory activity. Investigate a status of art for the operational criteria of spent fuel interm wet storage. Collect relevant laws, decree, notices and standards related to the operation of storage facility and study on the legislation system. Develop a draft of technical standards and criteria to be legislated. Define an evaluation system for the uncertainty analysis and study on the status of art in the field of criticality safety analysis. Develop an uncertainty evaluation system in criticality analysis with burnup credit and investigate an applicability as well as its benefits of this policy.

  19. Improving freight fire safety : experiment testing and computer modeling to further development of mist-controlling additives for fire mitigation.

    2012-08-01

    With the purpose to minimize or prevent crash-induced fires in road and rail transportation, the : current interest in bio-derived and blended transportation fuels is increasing. Based on two years : of preliminary testing and analysis, it appears to...

  20. Criticality safety of storage barrels for enriched uranium fresh fuel at the RB research reactor

    Pesic, M. P.

    1997-01-01

    Study on criticality safety of fresh low and high enriched uranium (LEU and HEU) fuel elements in the storage/transport barrels at the RB research reactor is carried out by using the well-known MCNP computer code. It is shown that studied arrays of tightly closed fuel barrels, each entirely loaded with 100 fresh (HEU or LEU) fuel slugs, are far away from criticality, even in cases of an unexpected flooding by light water.(author)

  1. Key technical issues relating to safety of spent fuel dry storage in vaults: CASCAD system

    Berge, F [Societe Generale pour les Techniques Nouvelles (SGN), 78 - Saint-Quentin-en-Yvelines (France)

    1994-12-31

    The operating CASCAD Facility at the Cadarashe site (FR) was commissioned in May 1990. Fuel is received in tight canisters which are transferred to storage pits in the vault and scheduled to be stored for up to 50 years. Canistering operations are performed in a cell of the reactor building.The paper describes the main functions of the facility as: cask receipt and shipping; fuel unloading; fuel conditioning; canisters emplacements in storage location; fuel storage; fuel retrieving and shipping at the end of the storage period; operation system and operation organization. Safety characteristics of the facility discussed are: fuel decay heat removal; subcriticality control and radiological protection. The fuel decay heat removal has two main purposes: (1) maintaining rod cladding temperature below a set limit in order to keep the fuel in its as received condition; (2) maintaining structures and equipment performing a safety function below the design temperature. The features of the sub-criticality control in the storage vault are such that sub-criticality in normal and accidental conditions is provided by the arrangement of pits in the vault. Radiological protection is based on limiting collective and individual annual dose equivalent to ALARA levels ensuring that they remain in any case below the set limits. Radiological protection system described consists in: confinement of radioactive materials for protection against its dissemination; radiation shielding for protection against irradiation. It is pointed out that all technical solutions presented are based on or adapted from proven technologies used in operating facilities in France or in other countries. The solution not only benefits from the experience of SGN in the design, construction and start-up of facilities for fuel or high level waste handling and storage, but also from the experience of the CEA and COGEMA groups in operating such facilities. 2 figs., 1 ref.

  2. CFD simulation of a fire in the living area of three storey residential house to evaluate life safety in houses

    Bounagui, A.; Benichou, N.; Kashef, A.; McCartney, C.

    2004-01-01

    Over time there have been changes in construction practices, building designs and materials and construction technologies. The Institute for Research in Construction (IRC) at the National Research Council of Canada (NRC) is undertaking research project to determine the impact of innovative residential construction products and systems on the fire safety of houses. The research study includes two phases: experimental and numerical. A new three-level full-scale experimental facility, representing a typical single-family house, has been built to study the structural fire performance, smoke movement and tenability conditions in the event of a fire. In the event of a fire in the first storey of a house, fire and smoke can move up to the main and second floors either through an open door or any openings in the floor structure between the basement and the main floor rendering the upper floor untenable for the occupants. Using CFD simulations this paper investigates the effect of the state of a stairwell door (opened or closed) on the fire development as well as on the moving up of the toxic gases to the upper floors. Simulation results were then used to estimate the time when conditions would become untenable, based on criteria found in the literature. (author)

  3. Assessment of safety and health of storage workers - a psychosocial approach

    Joanna Sadłowska-Wrzesińska

    2016-03-01

    Full Text Available Background: Although there is still a lot to do as far as prevention and elimination of traditional health and work safety hazards is concerned, the problem of psychosocial risk prevention is extremely important nowadays. It is crucial to take into consideration the health of workers and promotion of health in the workplace, as the occupational stress epidemics is getting more and more widespread. Methods: The article is based on the statistic analysis of accidents at work as well as the analysis of health problems resulting from the job itself. The latest work safety reports have been reviewed and special attention has been paid to psychosocial risk analysis. The author has tried to explicate the terms of new and emerging risks as regards storage work. Results: Various threat aspects of storage work have been evaluated. Deficits in psychosocial hazard identification have been indicated. What is more, no correlation between occupational tasks of storage workers and their knowledge about psychosocial risks has been emphasized.  An exemplified approach to warehouse psychosocial threat identification has been presented. The approach is based on the diagnosis of the current situation.  Conclusions: The psychosocial risk of storage work may lead to health deterioration, greater accident risk and worse performance at work. Such consequences mean that the psychosocial risks affect both an individual and the organization. Therefore, we should expect more intense efforts to increase psychosocial risk awareness of both employers and employees.

  4. Criticality safety of transuranic storage arrays at the Waste Isolation Pilot Plant

    Boyd, W.A.; Fecteau, M.W.

    1993-01-01

    The Waste Isolation Pilot Plant (WIPP) facility is designed to store transuranic waste that will consist mainly of surface contaminate articles and sludge. The fissile material in the waste is predominantly 239 Pu. The waste is grouped into two categories: contact-handled waste, which will be stored in 55-gal steel drums or in steel boxes, and remote-handled waste, which will be stored in specially designed cylindrical steel canisters. To show that criticality safety will be acceptable, criticality analyses were performed to demonstrate that a large number of containers with limiting loadings of fissile material could be stored at the site and meet a k eff limit of 0.95. Criticality analyses based on the classic worst-case moderated plutonium sphere approach would severely limit the capacity for storage of waste at the facility. Therefore, these analyses use realistic or credible worst-case assumptions to better represent the actual storage situation without compromising the margin of safety. Numerous sensitivity studies were performed to determine the importance of various parameters on the criticality of the configuration. It was determined that the plutonium loading has the dominant effect on the system reactivity. Nearly all other reactivity variations from the sensitivity studies were found to be relatively small. The analysis shows that criticality of the contact-handled waste storage drums and boxes and the remote-handled canisters is prevented by restrictions on maximum fissile loading per container and on the size of handling/storage areas

  5. Operation of Browns Ferry, Units 1 and 2 following the March 22, 1975 fire. Safety evaluation report

    1976-03-01

    The Safety Evaluation Report issued February 23, 1976, presents the NRC evaluation regarding the acceptability of the restoration and modifications at the Browns Ferry Plant Units 1 and 2, following the March 22, 1975 fire, to establish that the facility may be operated in the restored and modified condition without endangering the health and safety of the public. The modifications involved enhancing separation of redundant safeguards equipment by some rerouting of cable and by the application of a fire-retardant coating to the cable; enhancing fire extinguishing capability by the addition of fixed spray and sprinkler systems and expanded smoke and heat detection systems; and enhancing the overall fire protection program by changes in procedures, training, and organization. The NRC staff indicated some items that remained to be resolved prior to operation and concluded that subject to their satisfactory resolution the restoration of Browns Ferry Nuclear Plants Units 1 and 2 including the modifications is acceptable and that there is reasonable assurance that the health and safety of the public will not be endangered by operation of the facility as restored and modified

  6. Criticality Safety Evaluation for 30B and 48X UF6 Cylinders for Transportation and Storage

    Mokhatri, Homami Zahra; Nematollahi, Mohammadreza; Kamyab, Shahabeddin

    2011-01-01

    30B and 48X cylinders are two standard containers have been used for transportation and storage of uranium hexafluoride with 21/2-ton and 10-ton loading capacity, respectively. For the sake of nuclear safety, the long-term safe storage and transportation of the cylinders are necessary to be concerned. Safe limits in handling and storage of 30B and 48X cylinders from the criticality safety considerations, has been investigated in this paper, by using the MCNP.4C code with ENDF/B-VI library data for the neutron cross sections. An infinite array model (with and without over pack) incorporating an internal H/U ratio of 0.088 was then developed to determine the optimal interstitial moderation. The maximum k eff value for the conditions of optimal interstitial moderation with the premise of no water leakage into the UF 6 cylinder has been shown to be 0.79209 ± 0.0011 for the 30B cylinder and 0.7625±0.0013 for 48X cylinder with 5 wt % 235 U enrichment. Based on this evaluation, the 30B and 48X UF 6 cylinders with 5 wt % 235 U enrichment meet the 10 CFR part 71 criteria for Fissile Class I packages, even in the worst case, and has a Transport Index (TI) of zero for criticality safety purposes

  7. Performance Assessment and analysis of national building codes with fire safety in all wards of a hospital

    M. Mahdinia

    2009-04-01

    Full Text Available Background and aimsAIDS as a re-emergent disease and Viral hepatitis (B and C as one of thBackground and objective: Fire safety is an important problem in hospitals. Movement less, lack of awareness and special situation of residents are the reasons of this subject. In more countries such as Iran, fire protection regulations have compiled within the framework of national building codes. Current building codes don't create sufficient safety for patient in the hospitals in different situations and more of the advanced countries in the world effort to establish building code, base  on performance. This study to be accomplished with this goal that determination of fire risk level in the wards of a hospital and survey the efficiency of the national building codes. Methodsfire risk assesses is done, using "engineering fire risk assessment method" with the checklist for Data gathering. In this manner, risk calculate in all compartments and in the next  stage for survey the effect of building codes, with this supposition that all compartment is  conforming to building code requirement, risk level calculate in two situation.Resultsthe results of present study reveals that, risk level in all wards is more than one and even though risk less than one is acceptable, consequently minimum of safely situations didn't  produce in most wards. The results show the national building code in the different conditions  don't have appropriate efficient for creation of suitable safety. Conclusionin order to access to a fire safety design with sufficient efficiency, suitable selection is use of risk assessment based on, design methods.

  8. Fire protection

    Janetzky, E.

    1980-01-01

    Safety and fire prevention measurements have to be treated like the activities developing, planning, construction and erection. Therefore it is necessary that these measurements have to be integrated into the activities mentioned above at an early stage in order to guarantee their effectiveness. With regard to fire accidents the statistics of the insurance companies concerned show that the damage caused increased in the last years mainly due to high concentration of material. Organization of fire prevention and fire fighting, reasons of fire break out, characteristics and behaviour of fire, smoke and fire detection, smoke and heat venting, fire extinguishers (portable and stationary), construction material in presence of fire, respiratory protection etc. will be discussed. (orig./RW)

  9. Evaluation of Fire Hazard and Safety Management of Heritage Buildings in Georgetown, Penang

    Othuman Mydin M.A.; Sani N. Md; Abas N.F.; Khaw Y.Y.

    2014-01-01

    Fire is a subject that is always neglected and ignored as far as heritage buildings are concerned. Unlike newly-built buildings, which are required under UBBL to undergo certain fire protection system tests, people are less likely to carry out such tests and detailed assessments for heritage buildings. Thus, this research is significant as it is aimed at accomplishing several objectives including studying the current fire emergency plan, besides identifying and assessing the possible fire haz...

  10. Canister storage building (CSB) safety analysis report phase 3: Safety analysis documentation supporting CSB construction

    Garvin, L.J.

    1997-01-01

    The Canister Storage Building (CSB) will be constructed in the 200 East Area of the U.S. Department of Energy (DOE) Hanford Site. The CSB will be used to stage and store spent nuclear fuel (SNF) removed from the Hanford Site K Basins. The objective of this chapter is to describe the characteristics of the site on which the CSB will be located. This description will support the hazard analysis and accident analyses in Chapter 3.0. The purpose of this report is to provide an evaluation of the CSB design criteria, the design's compliance with the applicable criteria, and the basis for authorization to proceed with construction of the CSB

  11. IoT-Based Intelligent Modeling of Smart Home Environment for Fire Prevention and Safety

    Faisal Saeed

    2018-03-01

    Full Text Available Fires usually occur in homes because of carelessness and changes in environmental conditions. They cause threats to the residential community and may result in human death and property damage. Consequently, house fires must be detected early to prevent these types of threats. The immediate notification of a fire is the most critical issue in domestic fire detection systems. Fire detection systems using wireless sensor networks sometimes do not detect a fire as a consequence of sensor failure. Wireless sensor networks (WSN consist of tiny, cheap, and low-power sensor devices that have the ability to sense the environment and can provide real-time fire detection with high accuracy. In this paper, we designed and evaluated a wireless sensor network using multiple sensors for early detection of house fires. In addition, we used the Global System for Mobile Communications (GSM to avoid false alarms. To test the results of our fire detection system, we simulated a fire in a smart home using the Fire Dynamics Simulator and a language program. The simulation results showed that our system is able to detect early fire, even when a sensor is not working, while keeping the energy consumption of the sensors at an acceptable level.

  12. Propulsion and Energetics Panel Working Group 11 on Aircraft Fire Safety. Volume 2. Main Report

    1979-11-01

    which make burning metal particles a potent igni- tion source and extinguishment of bulk metal fires a difficult task. In the latter case, the difficulty...aircraft to fires induced by uncon- tained engine failures and internal engine metal fires . With respect to the uncontained engine failure current engine

  13. Modeling the effects of fire severity and climate warming on active layer thickness and soil carbon storage of black spruce forests across the landscape in interior Alaska

    Genet, H; Euskirchen, E S; McGuire, A D; Barrett, K; Breen, A; Bennett, A; Rupp, T S; Johnstone, J F; Kasischke, E S; Melvin, A M; Mack, M C; Schuur, A E G; Turetsky, M R; Yuan, F

    2013-01-01

    of 1.1 m on average by 2100. The combination of warming and fire led to a simulated cumulative loss of 9.6 kgC m −2 on average by 2100. Our analysis suggests that ecosystem carbon storage in boreal forests in interior Alaska is particularly vulnerable, primarily due to the combustion of organic layer thickness in fire and the related increase in active layer thickness that exposes previously protected permafrost soil carbon to decomposition. (letter)

  14. Modeling the performance of coated LPG tanks engulfes in fires

    Cozzani, V.; Landucci, G.; Molag, M. (Menso)

    2009-01-01

    The improvement of passive fire protection of storage vessels is a key factor to enhance safety among the LPG distribution chain. A thermal and mechanical model based on finite elements simulations was developed to assess the behaviour of full size tanks used for LPG storage and transportation in

  15. Processing and storage of blood components: strategies to improve patient safety

    Pietersz RNI

    2015-08-01

    Full Text Available Ruby NI Pietersz, Pieter F van der Meer Department of Product and Process Development, Sanquin Blood Bank, Amsterdam, the Netherlands Abstract: This review focuses on safety improvements of blood processing of various blood components and their respective storage. A solid quality system to ensure safe and effective blood components that are traceable from a donor to the patient is the foundation of a safe blood supply. To stimulate and guide this process, National Health Authorities should develop guidelines for blood transfusion, including establishment of a quality system. Blood component therapy enabled treatment of patients with blood constituents that were missing, only thus preventing reactions to unnecessarily transfused elements. Leukoreduction prevents many adverse reactions and also improves the quality of the blood components during storage. The safety of red cells and platelets is improved by replacement of plasma with preservative solutions, which results in the reduction of isoantibodies and plasma proteins. Automation of blood collection, separation of whole blood into components, and consecutive processing steps, such as preparation of platelet concentrate from multiple donations, improves the consistent composition of blood components. Physicians can better prescribe the number of transfusions and therewith reduce donor exposure and/or the risk of pathogen transmission. Pathogen reduction in cellular blood components is the latest development in improving the safety of blood transfusions for patients. Keywords: blood components, red cell concentrates, platelet concentrates, plasma, transfusion, safety 

  16. Standard review plan for reviewing safety analysis reports for dry metallic spent fuel storage casks

    1988-01-01

    The Cask Standard Review Plan (CSRP) has been prepared as guidance to be used in the review of Cask Safety Analysis Reports (CSARs) for storage packages. The principal purpose of the CSRP is to assure the quality and uniformity of storage cask reviews and to present a well-defined base from which to evaluate proposed changes in the scope and requirements of reviews. The CSRP also sets forth solutions and approaches determined to be acceptable in the past by the NRC staff in dealing with a specific safety issue or safety-related design area. These solutions and approaches are presented in this form so that reviewers can take consistent and well-understood positions as the same safety issues arise in future cases. An applicant submitting a CSAR does not have to follow the solutions or approaches presented in the CSRP. However, applicants should recognize that the NRC staff has spent substantial time and effort in reviewing and developing their positions for the issues. A corresponding amount of time and effort will probably be required to review and accept new or different solutions and approaches

  17. Advice about the safety of graphite storage silos of Saint Laurent des Eaux facility

    2005-01-01

    This document is the safety analysis made by the national association of the local commissions of information about nuclear activities (ANCLI), about the safety of graphite storage silos of Saint Laurent des Eaux nuclear facility. The analysis covers: the operation safety and the accident hypothesis, the monitoring of indoor and outdoor contamination in routine situation, the geotechnical characteristics of the site environment, the isotopic inventory and the estimation of radioactivity in routine and accidental situation, the estimation of doses received by the population in accidental situation and the internal emergency plan. After examination of these different points, the scientific committee of the ANCLI considers that a new global evaluation of risks, which integrates more recent exposure data, has to be carried out. (J.S.)

  18. Fuzzy fault tree assessment based on improved AHP for fire and explosion accidents for steel oil storage tanks.

    Shi, Lei; Shuai, Jian; Xu, Kui

    2014-08-15

    Fire and explosion accidents of steel oil storage tanks (FEASOST) occur occasionally during the petroleum and chemical industry production and storage processes and often have devastating impact on lives, the environment and property. To contribute towards the development of a quantitative approach for assessing the occurrence probability of FEASOST, a fault tree of FEASOST is constructed that identifies various potential causes. Traditional fault tree analysis (FTA) can achieve quantitative evaluation if the failure data of all of the basic events (BEs) are available, which is almost impossible due to the lack of detailed data, as well as other uncertainties. This paper makes an attempt to perform FTA of FEASOST by a hybrid application between an expert elicitation based improved analysis hierarchy process (AHP) and fuzzy set theory, and the occurrence possibility of FEASOST is estimated for an oil depot in China. A comparison between statistical data and calculated data using fuzzy fault tree analysis (FFTA) based on traditional and improved AHP is also made. Sensitivity and importance analysis has been performed to identify the most crucial BEs leading to FEASOST that will provide insights into how managers should focus effective mitigation. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Periodic Safety Review in Interim Storage Facilities - Current Regulation and Experiences in Germany

    Neles, Julia Mareike; Schmidt, Gerhard

    2014-01-01

    Periodic safety reviews in nuclear power plants in Germany have been performed since the end of the 1980's as an indirect follow-up of the accident in Chernobyl and, in the meantime, are formally required by law. During this process the guidelines governing this review were developed in stages and reached their final form in 1996. Interim storage facilities and other nuclear facilities at that time were not included, so the guidelines were solely focused on the specific safety issues of nuclear power plants. Following IAEA's recommendations, the Western European Nuclear Regulator Association (WENRA) introduced PSRs in its safety reference levels for storage facilities (current version in WGWD report 2.1 as of Feb 2011: SRLs 59 - 61). Based on these formulations, Germany improved its regulation in 2010 with a recommendation of the Nuclear Waste Management Commission (Entsorgungskommission, ESK), an expert advisory commission for the federal regulatory body BMU. The ESK formulated these detailed requirements in the 'ESK recommendation for guides to the performance of periodic safety reviews for interim storage facilities for irradiated fuel elements and heat-generating radioactive waste'. Before finalization of the guideline a test phase was introduced, aimed to test the new regulation in practice and to later include the lessons learned in the final formulation of the guideline. The two-year test phase started in October 2011 in which the performance of a PSR will be tested at two selected interim storage facilities. Currently these recommendations are discussed with interested/concerned institutions. The results of the test phase shall be considered for improvements of the draft and during the final preparation of guidelines. Currently the PSR for the first ISF is in an advanced stage, the second facility just started the process. Preliminary conclusions from the test phase show that the implementation of the draft guideline requires interpretation. The aim of a

  20. Radioactive waste storage facilities, involvement of AVN in inspection and safety assessment

    Simenon, R.; Smidts, O.

    2006-01-01

    The legislative and regulatory framework in Belgium for the licensing and the operation of radioactive waste storage buildings are defined by the Royal Decree of 20 July 2001 (hereby providing the general regulations regarding to the protection of the population, the workers and the environment against the dangers of ionising radiation). This RD introduces in the Belgian law the radiological protection and ALARA-policy concepts. The licence of each nuclear facility takes the form of a Royal Decree of Authorization. It stipulates that the plant has to be in conformity with its Safety Analysis Report. This report is however not a public document but is legally binding. Up to now, the safety assessment for radioactive waste storage facilities, which is implemented in this Safety Analysis Report, has been judged on a case-by-case basis. AVN is an authorized inspection organisation to carry out the surveillance of the Belgian nuclear installations and performs hereby nuclear safety assessments. AVN has a role in the nuclear safety and radiation protection during all the phases of a nuclear facility: issuance of licenses, during design and construction phase, operation (including reviewing and formal approval of modifications) and finally the decommissioning. Permanent inspections are performed on a regular basis by AVN, this by a dedicated site inspector, who is responsible for a site of an operator with nuclear facilities. Besides the day-to-day inspections during operation there are also the periodic safety reviews. AVN assesses the methodological approaches for the analyses, reviews and approves the final studies and results. The conditioned waste in Belgium is stored on the Belgoprocess' sites (region Mol-Dessel) for an intermediate period (about 80 years). In the meantime, a well-defined inspection programme is being implemented to ensure that the conditioned waste continues to be stored safely during this temporary storage period. This programme was draw up by

  1. Filter safety tests under solvent fire in a cell of nuclear-fuel reprocessing plant

    Nishio, Gunji

    1988-01-01

    In a nuclear-fuel reprocessing plant, a solvent fire in an extraction process is postulated. Since 1983, large scale solvent fire tests were carried out by Fire/Filter Facility to demonstrate solvent burning behavior in the cell, HEPA filter integrity by the fire and radioactive confinement by air-ventilation of the plant under postulated fire conditions. From results of 30 % TBP-70 % n-dodecane fire, burning rate of solvent in the cell, smoke generation rate and smoke deposition onto duct surface were obtained by a relation between air-ventilation rate into the cell and burning surface area of the solvent. The endurance of HEPA filter due to smoke plugging was measured by a pressure drop across the filter during the fire. The confinement of radioactive materials from the burning solvent was determined by the measurement of airborne concentrations in the cell for stable nuclei simulated fission products, radioactive tracers and uranium nitrate. (author)

  2. Games that "work": using computer games to teach alcohol-affected children about fire and street safety.

    Coles, Claire D; Strickland, Dorothy C; Padgett, Lynne; Bellmoff, Lynnae

    2007-01-01

    Unintentional injuries are a leading cause of death and disability for children. Those with developmental disabilities, including children affected by prenatal alcohol exposure, are at highest risk for injuries. Although teaching safety skills is recommended to prevent injury, cognitive limitations and behavioral problems characteristic of children with fetal alcohol spectrum disorder make teaching these skills challenging for parents and teachers. In the current study, 32 children, ages 4-10, diagnosed with fetal alcohol syndrome (FAS) and partial FAS, learned fire and street safety through computer games that employed "virtual worlds" to teach recommended safety skills. Children were pretested on verbal knowledge of four safety elements for both fire and street safety conditions and then randomly assigned to one condition. After playing the game until mastery, children were retested verbally and asked to "generalize" their newly acquired skills in a behavioral context. They were retested after 1 week follow-up. Children showed significantly better knowledge of the game to which they were exposed, immediately and at follow-up, and the majority (72%) was able to generalize all four steps within a behavioral setting. Results suggested that this is a highly effective method for teaching safety skills to high-risk children who have learning difficulties.

  3. Canister storage building (CSB) safety analysis report phase 3: Safety analysis documentation supporting CSB construction

    Garvin, L.J.

    1997-04-28

    The Canister Storage Building (CSB) will be constructed in the 200 East Area of the U.S. Department of Energy (DOE) Hanford Site. The CSB will be used to stage and store spent nuclear fuel (SNF) removed from the Hanford Site K Basins. The objective of this chapter is to describe the characteristics of the site on which the CSB will be located. This description will support the hazard analysis and accident analyses in Chapter 3.0. The purpose of this report is to provide an evaluation of the CSB design criteria, the design's compliance with the applicable criteria, and the basis for authorization to proceed with construction of the CSB.

  4. [Protecting Safety During Dust Fires and Dust Explosions - The Example of the Formosa Fun Coast Water Park Accident].

    Hsieh, Ming-Hong; Wu, Jia-Wun; Li, Ya-Cing; Tang, Jia-Suei; Hsieh, Chun-Chien

    2016-02-01

    This paper will explore the fire and explosion characteristics of cornstarch powder as well as strategies for protecting the safety of people who are involved a dust fire or dust explosion. We discuss the 5 elements of dust explosions and conduct tests to analyze the fire and explosion characteristics of differently colored powders (yellow, golden yellow, pink, purple, orange and green). The results show that, while all of the tested powders were difficult to ignite, low moisture content was associated with significantly greater risks of ignition and flame spread. We found the auto-ignition temperature (AIT) of air-borne cornstarch powder to be between 385°C and 405°C, with yellow-colored cornstarch powder showing the highest AIT and pink-colored cornstarch powder showing the lowest AIT. The volume resistivity of all powder samples was approximately 108 Ω.m, indicating that they were nonconductive. Lighters and cigarettes are effective ignition sources, as their lit temperatures are higher than the AIT of cornstarch powder. In order to better protect the safety of individuals at venues where cornstarch powder is released, explosion control measures such as explosion containment facilities, vents, and explosion suppression and isolation devices should be installed. Furthermore, employees that work at these venues should be better trained in explosion prevention and control measures. We hope this article is a reminder to the public to recognize the fire and explosion characteristics of flammable powders as well as the preventive and control measures for dust explosions.

  5. Information report on nuclear safety and radiation protection of the Manche storage Centre - 2012

    2013-06-01

    After a presentation of the Manche Storage Centre (CSM), the first French centre of surface storage of weakly and moderately radioactive wastes, of its history, its buildings and activities, of the multi-layer cover, of the water management system (installation, controls, sampling), this report describes the measures related to nuclear safety (principles and objectives, prevention measures, technical measures, regulatory plan of control of the Centre and of its environment, control of releases from storage installations, quality organisation, archiving system). It describes measures related to radiation protection: principles, staff dosimetry, and personnel safety. The next part presents the nuclear event scale (INES) and indicates that no incident occurred. The effluents and releases from the Centre are then addressed: origin, locations and results of radiological controls of rainfalls, of risky effluents, of underground waters, of rivers, impacts of the Centre on its environment (releases in the sea, in rivers). The management of conventional and nuclear wastes produced by the Centre is reviewed as well as the actions related to information and transparency. Recommendations of the CHSCT are reported

  6. Irradiated ignition over solid materials in reduce pressure environment: Fire safety issue in man-made enclosure system

    Nakamura, N.; Aoki, A.

    Effects of ambient pressure and oxygen yield on irradiated ignition characteristics over solid combustibles have been studied experimentally Aim of the present study is to elucidate the flammability and chance of fire in depressurized enclosure system and give ideas for the fire safety and fire fighting strategies in such environment Thin cellulosic paper is considered as the solid combustible since cellulose is one of major organic compounds and flammables in the nature Applied atmosphere consists of inert gas either CO2 or N2 and oxygen and various mixture ratios are of concerned Total ambient pressure level is varied from 0 1MPa standard atmospheric pressure to 0 02MPa Ignition is initiated by external thermal flux exposed into the solid surface as a model of unexpected thermal input to initiate the localized fire Thermal degradation of the solid induces combustible gaseous products e g CO H2 or other low class of HCs and the gas mixes with ambient oxygen to form the combustible mixture over the solid Heat transfer from the hot irradiated surface into the mixture accelerates the local exothermic reaction in the gas phase and finally thermal runaway ignition is achieved Ignition event is recorded by high-speed digital video camera to analyze the ignition characteristics Flammable map in partial pressure of oxygen Pox and total ambient pressure Pt plane is made to reveal the fire hazard in depressurized environment Results show that wider flammable range is obtained depending on the imposed ambient

  7. Environmental, safety, and health engineering

    Woodside, G.; Kocurek, D.

    1997-01-01

    A complete guide to environmental, safety, and health engineering, including an overview of EPA and OSHA regulations; principles of environmental engineering, including pollution prevention, waste and wastewater treatment and disposal, environmental statistics, air emissions and abatement engineering, and hazardous waste storage and containment; principles of safety engineering, including safety management, equipment safety, fire and life safety, process and system safety, confined space safety, and construction safety; and principles of industrial hygiene/occupational health engineering including chemical hazard assessment, personal protective equipment, industrial ventilation, ionizing and nonionizing radiation, noise, and ergonomics

  8. Site safety progress review of spent fuel central interim storage facility. Final report

    Gurpinar, A.; Serva, L.; Giuliani

    1995-01-01

    Following the request of the Czech Power Board (CEZ) and within the scope of the Technical Cooperation Project CZR/9/003, a progress review of the site safety of the Spent Fuel Central Interim Storage Facility (SFCISF) was performed. The review involved the first two stages of the works comprising the regional survey and identification of candidate sites for the underground and surface storage options. Five sites have been identified as a result of the previous works. The following two stages will involved the identification of the preferred candidate sites for the two options and the final site qualification. The present review had the purpose of assessing the work already performed and making recommendations for the next two stages of works

  9. Safety aspects of radioactive waste transportation and storage in the Republic of Moldova

    Gasca, Iu.

    2009-01-01

    A special attention continues to be given to the management of radioactive wastes. The National Department of Radioactive Waste Management is a unique institute in Moldova that deals with reception, transportation and storage of radioactive wastes. It collaborates with International Atomic Energy Agency. The management of low- and intermediate-level waste has remained permanently focused at the IAEA work. In 2003 IAEA supported the construction and technique of low-level and intermediate-level radioactive waste repository in Moldova. During 2003-2005 the US Department of Energy supported financing of planning and building of the underground storage for keeping the installations with high-level radioactive sources with all safety systems (signalization, video-monitoring). In 2008 the construction of radioactive wastes conditioning station was initiated with support of the US Embassy's Bureau for military cooperation

  10. Criticality safety studies for the storage of waste from nuclear fuel service in Intercell Storage Wells 2 and 3 of Building 3019

    Primm, R.T. III; Hopper, C.M.; Smolen, G.R.

    1992-11-01

    This report provides computational evaluation results demonstrating that mixed oxide waste can be safely stored in Intercell Storage Wells 2 and 3 of Building 3019 at the Oak Ridge National Laboratory. Existing, verified computational techniques are validated with applicable critical experiments and tolerance limits for safety analyses are derived. Multiplication factors for normal and credible abnormal configurations are calculated and found to be far subcritical when compared to derived safety limits

  11. Report of the international fire safety mission to Temelin, unit 1 nuclear power plant Czech Republic 4 to 14 February 1996

    1996-01-01

    This report presents the results of an IAEA Fire Safety Mission conducted within the scope of Technical Co-operation Project CZR/9/005 to assess the licensing process, design, analysis and operational management of the Temelin Nuclear Power Plant with regards to fire safety of the plant. The Temelin Nuclear Power Plant currently has two units under construction. Each unit is equipped with a pressurized water reactor of the WWER design with a net electrical output of about MWe. The plant has already made significant upgrading in fire protection from the original design. The Team's evaluation is based on the IAEA Safety Series No. 50-SG-D2 (Rev.1), Fire Protection in Nuclear Power Plants, and other fire protection guidelines currently produced by the IAEA. The evaluation, conclusions and recommendations presented in this report reflect the views of the Fire Safety Mission experts. The recommendations are provided for consideration by the responsible authorities in the Czech Republic towards enhancing fire safety at the Temelin plant

  12. Preliminary Safety Analysis Report for the Transuranic Storage Area Retrieval Enclosure at the Idaho National Engineering Laboratory

    1993-03-01

    This Transuranic Storage Area Retrieval Enclosure Preliminary Safety Analysis Report was completed as required by DOE Order 5480.23. The purpose of this document is to construct a safety basis that supports the design and permits construction of the facility. The facility has been designed to the requirements of a Radioactive Solid Waste Facility presented in DOE Order 6430.1A

  13. Design optimization and sensitivity analysis of a biomass-fired combined cooling, heating and power system with thermal energy storage systems

    Caliano, Martina; Bianco, Nicola; Graditi, Giorgio; Mongibello, Luigi

    2017-01-01

    Highlights: • A novel operation strategy for biomass-fired combined cooling, heating and power system is presented. • A design optimization of the system is conducted. • The effects of variation of the incentive for the electricity generation are evaluated. • The effects of the variation of the absorption chiller size and the thermal energy storage system one are evaluated. • The inclusion of a cold storage system into the combined cooling, heating and power system is also analyzed. - Abstract: In this work, an operation strategy for a biomass-fired combined cooling, heating and power system, composed of a cogeneration unit, an absorption chiller, and a thermal energy storage system, is formulated in order to satisfy time-varying energy demands of an Italian cluster of residential multi-apartment buildings. This operation strategy is adopted for performing the economical optimization of the design of two of the devices composing the combined cooling, heating and power system, namely the absorption chiller and the storage system. A sensitivity analysis is carried out in order to evaluate the impact of the incentive for the electricity generation on the optimized results, and also to evaluate, separately, the effects of the variation of the absorption chiller size, and the effects of the variation of the thermal energy storage system size on the system performance. In addition, the inclusion into the system of a cold thermal energy storage system is analyzed, as well, assuming different possible values for the cold storage system cost. The results of the sensitivity analysis indicate that the most influencing factors from the economical point of view are represented by the incentive for the electricity generation and the absorption chiller power. Results also show that the combined use of a thermal energy storage and of a cold thermal energy storage during the hot season could represent a viable solution from the economical point of view.

  14. Fire science at LLNL: A review

    Hasegawa, H.K. (ed.)

    1990-03-01

    This fire sciences report from LLNL includes topics on: fire spread in trailer complexes, properties of welding blankets, validation of sprinkler systems, fire and smoke detectors, fire modeling, and other fire engineering and safety issues. (JEF)

  15. 30 CFR 56.6405 - Firing devices.

    2010-07-01

    ... HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Explosives Electric Blasting § 56... all electric detonators to be fired with the type of circuits used. Storage or dry cell batteries are not permitted as power sources. (b) Blasting machines shall be tested, repaired, and maintained in...

  16. 30 CFR 57.6405 - Firing devices.

    2010-07-01

    ... HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Explosives Electric Blasting... sufficient current to energize all electric detonators to be fired with the type of circuits used. Storage or dry cell batteries are not permitted as power sources. (b) Blasting machines shall be tested, repaired...

  17. Improvement of numerical simulation methods on safety assessment of the spent fuel storage facility

    NONE

    2013-08-15

    Improvement of numerical simulation methods on safety assessment of the spent fuel storage facility is one of main objectives of JNES activities. For the thermal and structural analyses, the radiative heat transfer analysis code S-FOKS has been developed to reduce computing time and to avoid using large memory area. In order to simulate the specular reflection, a new model (called 'model-2') is planned to install to S-FOKS code. The theoretical values with the specular reflection in simple geometry were lead to verify S-FOKS model-2. (author)

  18. Criticality safety analysis of the fissile material storage arrays in the east end of building 6592

    McKeon, D.C.; Philbin, J.S.

    1981-03-01

    A criticality safety analysis of nine concrete storage holes that have been formed in the floor of the Materials Balance Area (MBA) in Building 6592 is reported. Unit cell dimensions and unit mass limits are defined for the most likely plutonium and uranium fuel types that will be stored there. Two tables of mass limits are derived. The first table is to be used for short units that can be stacked with fixed separation in the same hole. The second table will permit units greater than one foot in length providing that the appropriate linear mass density limit (in kg/ft) is not exceeded

  19. Comfort-calculation programme for wood-fired storage ovens; Komfortberechnungsprogramm fuer Holz-Speicheroefen

    Gaegauf, Ch.; Zumsteg, H. [Oekozentrum Langenbruck, Langenbruck (Switzerland); Huber, H.; Schuetz, B.; Friedlin, R. [Hochschule fuer Technik und Architektur (HTA), Horw (Switzerland); Chiquet, C. [Verband Schweizerischer Hafner- und Plattengeschaefte (VHP), Olten (Switzerland)

    2004-07-01

    This report for the Swiss Federal Office of Energy (SFOE) describes a computer aided design (CAD) tool for the design of wood-fired heating appliances to meet optimal room comfort demands. The CAD-tool combines numeric simulation of the heat requirements of dwellings with the dynamic simulation of appliances with slow heat release characteristics. The software simulates the building, the heat output of the wood stove and the heat exchange between the floors. With the help of an Internet-based interface, the user can calculate the heat demand of his building. After this, the stove designer optimises the wood stove with the help of simulation software, which runs on a central server. As a result, the user gets the temperature profile for each room of the building and also the heat output profile of the wood stove for each room by E-mail. The validation of a simulation using a mock-up of a slow heat release appliance and its application to two dwellings equipped with slow heat release appliances is described. According to the authors, the room temperatures computed by the CAD-tool fitted the temperatures measured in situ well. The numerous results are presented in graphical form and commented on.

  20. Safety of spent fuel elements storage under water at La Hague facility

    Guezenec, J.Y.

    1990-12-01

    Awaiting for a decision about radioactive waste repository, the spent fuel elements are stored in the storage pools at the La Hague facility. The water in the pools is permanently cooled and purified to maintain the temperature, radioactivity and chemical pollution under preset limits. The first safety problem is concerned with the spent fuel transport casks. Opening of the casks is done under water in a number of facilities. The most recent approach is done by the company To, which established dry manipulation which enables to minimise the risk of possible cask failures as well as external contamination of cooling fins of the casks. Another general safety related problem is related to criticality risk caused by possible cooling failures or by external events like earthquakes. Special probability limit is set up for seismic events to be less than 10 -7 /year. Equally, risk of fuel assembly failures due to possible chocs and possibility of defects in pool isolation are taken into account [fr

  1. Aube storage center. Information report on nuclear safety and radiation protection 2015

    2016-01-01

    The National Radioactive Waste Management Agency (Andra), was established by the December 1991 Waste Act as a public body in charge of the long-term management of all radioactive waste, under the supervision of the Ministry of Ecology, Energy, Sustainable Development and the Sea (formerly the Ministry of Industry and the Ministry of Environment), and the Ministry of Research. The Andra operates two storage centers in the Aube region (France): the center for short-lived low- and intermediate-level wastes, and the center for very-low-level radioactive wastes. This document is the 2015 activity report of the center for short-lived low- and intermediate-level wastes. It presents a review of the activities of the center: presentation of the installations, safety and radiation protection, security, events or incidents, environmental monitoring and effluents, wastes management, public information, recommendations of the Health and safety Committee (CHSCT)

  2. Aube storage center. Information report on nuclear safety and radiation protection 2016

    2017-01-01

    The National Radioactive Waste Management Agency (Andra), was established by the December 1991 Waste Act as a public body in charge of the long-term management of all radioactive waste, under the supervision of the Ministry of Ecology, Energy, Sustainable Development and the Sea (formerly the Ministry of Industry and the Ministry of Environment), and the Ministry of Research. The Andra operates two storage centers in the Aube region (France): the center for short-lived low- and intermediate-level wastes, and the center for very-low-level radioactive wastes. This document is the 2016 activity report of the center for short-lived low- and intermediate-level wastes. It presents a review of the activities of the center: presentation of the installations, safety and radiation protection, security, events or incidents, environmental monitoring and effluents, wastes management, public information, recommendations of the Health and safety Committee (CHSCT)

  3. Determination Of Measures That The Operating Nurses Take For The Fire Safety: Example Of Karabuk

    Isil Isik Andsoy

    2012-06-01

    Material and Methods: The research group consisted of 32 operating room nurses in Karabuk hospitals who accept volunteer to participate. The data were collected with face to face interviews. Questionnaire was prepared by the researcher with the accompaniment of literature. Evaluation of the data, number and percentage were used. Results: In this study, 96.9% of the nurses have indicated that precautionary measures are taken against fire, and 75% of them have reported to have fire extinguishers and alarm system, and also 93.8% of them have stated that maintenance of existing systems in the operating room is done at certain intervals. Furthermore, 87.6% of the nurses have noted to have a fire extinguisher instruction in the operating room, and 62.5% of them have remarked that there are fire exit signs. Conclusion: Finally all of the nurses have indicated that routine checks of the operating rooms' electirical system are done. It has been found out that most of the nurses are knowledgable but inadequate about precautions against fire. As a result, it has been recommended to do an emergency planning in case of fires in operating rooms; to teach this plan to nurses, anesthetists, surgeon and other surgical team by fire drills; to train surgical team about fire risks and measures and to repeat this training regularly. [J Contemp Med 2012; 2(2.000: 87-93

  4. Fire Safety Aspects of Polymeric Materials. Volume 3. Smoke and Toxicity (Combustion Toxicology of Polymers)

    1978-01-01

    complete combustion of these polymers and thus minimize cyanide formation (Ball and Boettner, 1973; Junod , 1976). This one example shows the critical...34Visibility Through Fire Smoke," II. Report of Fire Research Institute of Japan. No. 33. pp. 31-49, 1971. T. L. Junod , "Gaseous Emissions and Toxic Hazard

  5. Measures for ensuring hydrogen fire and explosion safety for VVER-440/230

    Bezlepkin, V.; Semashko, S.; Svetlov, S.; Sidorov, V.; Ivkov, I.; Krylov, Yu.; Kukhtevich, V.

    2004-01-01

    This paper deals with the findings of calculation analysis as regards the release of mass, energy and hydrogen during beyond-design-basis accident (BDBA) at Kola NPP equipped with VVER-440 reactor (B-230 design) and in respect of distribution of hydrogen throughout NPP tight compartments. The analysis figures out the number and locations of passive catalytic hydrogen recombiners and of the sensors of the hydrogen concentration monitoring system. In order to prove the hydrogen safety of the design, it has been necessary to review accidents accompanied by maximum emissions (both peak and integral ones) of hydrogen into the tight area. During design-basis accident (DBA), no steam/zirconium reactions occur in the reactor core. Out of BDBA, the severe accidents with damage to the core accompanied oxidative reactions between zirconium and steel with emission of hydrogen are regarded as the most dangerous ones. Assessment of additional hydrogen sources shows that the contribution of such sources to the total amount of hydrogen that may emit during a severe accident is insignificant. Calculations have been made for the following scenarios of severe accidents, which seem to be the most important in terms of hydrogen safety analysis: - 20 mm leak from the primary circuit in combination with a failure of the emergency makeup system; - 500 mm PCP rupture in the vicinity of reactor inlet branch with bi-lateral leakage of coolant. Releases of mass and energy during the aforesaid scenarios, changes of medium parameters within the tight compartments and analysis of possible fire conditions have been analyzed by means of Russian computer codes RATEG/SVECHA/HEFEST, KUPOL-M and LIMITS. The said analysis shows that the large break accident (500 mm), i.e. PCP rupture in the vicinity of the reactor branch with bi-lateral leakage of coolant is of the keen interest in terms of hydrogen safety. This accident typifies powerful short-term release of hydrogen at a significantly lesser

  6. Manche storage Centre. Information report on nuclear safety and radiation protection 2014. Annual report 2014

    2015-06-01

    After a presentation of the Manche Storage Centre (CSM), the first French centre of surface storage of weakly and moderately radioactive wastes, of its history, its buildings and activities, of the multi-layer cover, of the water management system (installation, controls, sampling), this report then describes the measures related to nuclear safety (principles and objectives), the management of conventional and nuclear wastes produced by the Centre and its other environmental impacts. The follow up of the installations and of their effluents and releases are then addressed: origin, locations and results of radiological controls of rainfalls, of risky effluents, of underground waters, of rivers, impacts of the Centre on its environment (releases in the sea, in rivers, in sediments). The measures related to radiation protection are described: principles, staff dosimetry, and personnel safety. The next part presents the nuclear event scale (INES) and indicates that no incident occurred in 2014. Finally the actions related to public information and transparency are summarized. Recommendations of the CHSCT are reported at the end

  7. SAFETY

    M. Plagge, C. Schaefer and N. Dupont

    2013-01-01

    Fire Safety – Essential for a particle detector The CMS detector is a marvel of high technology, one of the most precise particle measurement devices we have built until now. Of course it has to be protected from external and internal incidents like the ones that can occur from fires. Due to the fire load, the permanent availability of oxygen and the presence of various ignition sources mostly based on electricity this has to be addressed. Starting from the beam pipe towards the magnet coil, the detector is protected by flooding it with pure gaseous nitrogen during operation. The outer shell of CMS, namely the yoke and the muon chambers are then covered by an emergency inertion system also based on nitrogen. To ensure maximum fire safety, all materials used comply with the CERN regulations IS 23 and IS 41 with only a few exceptions. Every piece of the 30-tonne polyethylene shielding is high-density material, borated, boxed within steel and coated with intumescent (a paint that creates a thick co...

  8. Pressure surge free fire water systems increase safety on offshore oil- and gas drilling platforms

    Carlsen, Randi

    2001-01-01

    The article describes a new fire water system for use on the oil- and gas drilling platforms that is characterized by improved start-up time and reduced energy consumption. Deluge valves are commonly used in fast large-flow fire water systems all over the world. During the test of a new fire water system on a platform a few years ago, a pipe near the living quarter suddenly ruptured due to an unexpected pressure surge thought to be impossible. It was caused by a weakness of the deluge valve. A better valve was needed and the 'UniqValve' was designed and manufactured. The UniqValve operates in cooperation with the fire pumps during start-up as it 'reads' the pressure variations of the water flow and corrects the water flow to the fire areas in less than a tenth of a second. The valve is now integrated in a modular system. The fire water unit is mounted in a container, which reduces cost and simplifies the placement of the fire water installation

  9. Adsorber fires

    Holmes, W.

    1987-01-01

    The following conclusions are offered with respect to activated charcoal filter systems in nuclear power plants: (1) The use of activated charcoal in nuclear facilities presents a potential for deep-seated fires. (2) The defense-in-depth approach to nuclear fire safety requires that if an ignition should occur, fires must be detected quickly and subsequently suppressed. (3) Deep-seated fires in charcoal beds are difficult to extinguish. (4) Automatic water sprays can be used to extinguish fires rapidly and reliably when properly introduced into the burning medium. The second part of the conclusions offered are more like challenges: (1) The problem associated with inadvertent actuations of fire protection systems is not a major one, and it can be reduced further by proper design review, installation, testing, and maintenance. Eliminating automatic fire extinguishing systems for the protection of charcoal adsorbers is not justified. (2) Removal of automatic fire protection systems due to fear of inadvertent fire protection system operation is a case of treating the effect rather than the cause. On the other hand, properly maintaining automatic fire protection systems will preserve the risk of fire loss at acceptable levels while at the same time reducing the risk of damage presented by inadvertent operation of fire protection systems

  10. CRITICALITY SAFETY CONTROL OF LEGACY FUEL FOUND AT 105-K WEST FUEL STORAGE BASIN

    JENSEN, M.A.

    2005-01-01

    In August 2004, two sealed canisters containing spent nuclear fuel were opened for processing at the Hanford Site's K West fuel storage basin. The fuel was to be processed through cleaning and sorting stations, repackaged into special baskets, placed into a cask, and removed from the basin for further processing and eventual dry storage. The canisters were expected to contain fuel from the old Hanford C Reactor, a graphite-moderated reactor fueled by very low-enriched uranium metal. The expected fuel type was an aluminum-clad slug about eight inches in length and with a weight of about eight pounds. Instead of the expected fuel, the two canisters contained several pieces of thin tubes, some with wire wraps. The material was placed into unsealed canisters for storage and to await further evaluation. Videotapes and still photographs of the items were examined in consultation with available retired Hanford employees. It was determined that the items had a fair probability of being cut-up pieces of fuel rods from the retired Hanford Plutonium Recycle Test Reactor (PRTR). Because the items had been safely handled several times, it was apparent that a criticality safety hazard did not exist when handling the material by itself, but it was necessary to determine if a hazard existed when combining the material with other known types of spent nuclear fuel. Because the PRTR operated more than 40 years ago, investigators had to rely on a combination of researching archived documents, and utilizing common-sense estimates coupled with bounding assumptions, to determine that the fuel items could be handled safely with other spent nuclear fuel in the storage basin. As older DOE facilities across the nation are shut down and cleaned out, the potential for more discoveries of this nature is increasing. As in this case, it is likely that only incomplete records will exist and that it will be increasingly difficult to immediately characterize the nature of the suspect fissionable

  11. Safety issues related to the intermediate heat storage for the EU DEMO

    Carpignano, Andrea [NEMO group, Dipartimento Energia, Politecnico di Torino, C.so Duca degli Abruzzi 24, 10129 Torino (Italy); Pinna, Tonio [ENEA, 00044 Frascati (Italy); Savoldi, Laura; Sobrero, Giulia; Uggenti, Anna Chiara [NEMO group, Dipartimento Energia, Politecnico di Torino, C.so Duca degli Abruzzi 24, 10129 Torino (Italy); Zanino, Roberto, E-mail: roberto.zanino@polito.it [NEMO group, Dipartimento Energia, Politecnico di Torino, C.so Duca degli Abruzzi 24, 10129 Torino (Italy)

    2016-11-01

    Highlights: • IHS affects only the PHTS and the BoP (Balance of Plant). • PIEs list does not change but IHS influences PIEs evolution. • Additional issues to be addressed in PIEs study due to the implementation of HIS. • No safety/operational major obstacles were found for IHS concept. - Abstract: The functional deviations able to compromise system safety in the EU DEMO Primary Heat Transfer System (PHTS) with intermediate heat storage (IHS) based on molten salts are identified and compared to the deviations identified with PHTS without IHS. The resulting safety issues for the Balance of Plant (BoP) have been taken into account. Functional Failure Mode and Effects Analysis (FFMEA) is used to highlight the Postulated Initiating Events (PIE) of incident/accident sequences and to provide some safety insights during the preliminary design. The architecture of the system with IHS does not introduce new PIE with respect to the case without IHS, but it modifies some of them. In particular the two Postulated Initiating Events that are affected by the presence of IHS are the LOCA in the tubes of the HX between primary and intermediate circuit and the loss of heat sink for the first wall or the breeding zone. In fact the IHS introduces some advantages concerning the stability of the secondary circuit, but some weaknesses are associated to the physical-chemical nature of molten salts, especially oxidizing power, corrosive nature and risk of solidification. These issues can be managed in the design by the introduction of new safety functions.

  12. Sustainability Assessment of Coal-Fired Power Plants with Carbon Capture and Storage

    Widder, Sarah H.; Butner, R. Scott; Elliott, Michael L.; Freeman, Charles J.

    2011-11-30

    Carbon capture and sequestration (CCS) has the ability to dramatically reduce carbon dioxide (CO2) emissions from power production. Most studies find the potential for 70 to 80 percent reductions in CO2 emissions on a life-cycle basis, depending on the technology. Because of this potential, utilities and policymakers are considering the wide-spread implementation of CCS technology on new and existing coal plants to dramatically curb greenhouse gas (GHG) emissions from the power generation sector. However, the implementation of CCS systems will have many other social, economic, and environmental impacts beyond curbing GHG emissions that must be considered to achieve sustainable energy generation. For example, emissions of nitrogen oxides (NOx), sulfur oxides (SOx), and particulate matter (PM) are also important environmental concerns for coal-fired power plants. For example, several studies have shown that eutrophication is expected to double and acidification would increase due to increases in NOx emissions for a coal plant with CCS provided by monoethanolamine (MEA) scrubbing. Potential for human health risks is also expected to increase due to increased heavy metals in water from increased coal mining and MEA hazardous waste, although there is currently not enough information to relate this potential to actual realized health impacts. In addition to environmental and human health impacts, supply chain impacts and other social, economic, or strategic impacts will be important to consider. A thorough review of the literature for life-cycle analyses of power generation processes using CCS technology via the MEA absorption process, and other energy generation technologies as applicable, yielded large variability in methods and core metrics. Nonetheless, a few key areas of impact for CCS were developed from the studies that we reviewed. These are: the impact of MEA generation on increased eutrophication and acidification from ammonia emissions and increased toxicity

  13. Seerley Road Fire Site

    A barn caught fire at on Seerley Road, Indianapolis. Five storage drums believed to contain metallic potassium were involved in the fire. EPA will perform additional sampling as part of removal operations and safe offsite transportation.

  14. The Nuclear Safety Council's Instruction IS-30 on program requirements of fire protection at nuclear power plants; La instruccion IS-30 del consejo de Seguridad Nuclear sobre requisitos del programa de proteccion contraincendios en centrales nucleares

    Peco, J.

    2015-07-01

    The Nuclear Safety Councils Instrumentation IS-30 is the standard that establishes the fire protection program requirements for the Spanish nuclear power plants with operating license in order to satisfy the two fire protection objectives, which are the adoption of the defense-in-depth principle for fire protection and, by fire area confinement, to ensure that one train of components needed to achieve and maintain the safe shutdown conditions is free of fire damage, and that radioactive liberation is minimized. (Author)

  15. Performance and results of a fire probability safety analysis for the Grafenrheinfeld nuclear power plant

    Hristodulidis, A.; Meyer, A.W.

    2000-01-01

    The Full-Power PSA for the Grafenrheinfeld 1300 MWe pressurized water reactor covering the recommended initiating events of the German PSA Procedure Guide published in October 1990 was followed up by a Fire PSA meeting the requirements of the December 1996 edition of the PSA Procedure Guide. In the meantime the Fire PSA has been reviewed by the Authorized Expert, TUeV Bayern. The experts agreed with the methods used and the results obtained; they also suggested some improvements to be made in case of a revision, but these do not affect the overall results of the study. Comparing the core damage frequency caused by the initiating events of the Full-Power PSA (approx. 2.5 E-6/a) with the results of the Fire PSA (approx. 3.5 E-7/a), fire contributes approx. 12% to the overall core damage frequency. (orig.) [de

  16. Final Hazard Classification and Auditable Safety Analysis for the 105-F Building Interim Safe Storage Project

    Rodovsky, T.J.; Bond, S.L.

    1998-07-01

    The auditable safety analysis (ASA) documents the authorization basis for the partial decommissioning and facility modifications to place the 105-F Building into interim safe storage (ISS). Placement into the ISS is consistent with the preferred alternative identified in the Record of Decision (58 FR). Modifications will reduce the potential for release and worker exposure to hazardous and radioactive materials, as well as lower surveillance and maintenance (S ampersand M) costs. This analysis includes the following: A description of the activities to be performed in the course of the 105-F Building ISS Project. An assessment of the inventory of radioactive and other hazardous materials within the 105-F Building. Identification of the hazards associated with the activities of the 105-F Building ISS Project. Identification of internally and externally initiated accident scenarios with the potential to produce significant local or offsite consequences during the 105-F Building ISS Project. Bounding evaluation of the consequences of the potentially significant accident scenarios. Hazard classification based on the bounding consequence evaluation. Associated safety function and controls, including commitments. Radiological and other employee safety and health considerations

  17. Annex D 200 Area Interim Storage Area Final Safety Analysis Report Volume 5 (FSAR) (Section 1 and 2)

    CARRELL, R.D.

    2003-01-01

    The 200 Area Interim Storage Area (200 Area ISA) at the Hanford Site provides for the interim storage of non-defense reactor spent nuclear fuel (SNF) housed in aboveground dry cask storage systems. The 200 Area ISA is a relatively simple facility consisting of a boundary fence with gates, perimeter lighting, and concrete and gravel pads on which to place the dry storage casks. The fence supports safeguards and security and establishes a radiation protection buffer zone. The 200 Area ISA is nominally 200,000 ft 2 and is located west of the Canister Storage Building (CSB). Interim storage at the 200 Area ISA is intended for a period of up to 40 years until the materials are shipped offsite to a disposal facility. This Final Safety Analysis Report (FSAR) does not address removal from storage or shipment from the 200 Area ISA. Three different SNF types contained in three different dry cask storage systems are to be stored at the 200 Area ISA, as follows: (1) Fast Flux Test Facility (FFTF) Fuel--Fifty-three interim storage casks (ISC), each holding a core component container (CCC), will be used to store the FFTF SNF currently in the 400 Area. (2) Neutron Radiography Facility (NRF)TRIGA--One Rad-Vault container stores two DOT-6M 3 containers and six NRF TRIGA casks. (3) Commercial Light Water Reactor Fuel--Six International Standards Organization (ISO) containers, each holding a NAC-1 cask with an inner commercial light water reactor (LWR) canister, are used for storing commercial LWR SNF from the 300 Area. An aboveground dry cask storage location is necessary for the spent fuel because the current storage facilities are being shut down and deactivated. The spent fuel is being transferred to interim storage because there is no permanent repository storage currently available

  18. Preparedness of fire safety in underground train station: Comparison between train operators in Malaysia with other operators from the developed countries

    Tajedi, Noor Aqilah A.; Sukor, Nur Sabahiah A.; Ismail, Mohd Ashraf M.; Shamsudin, Shahrul A.

    2017-10-01

    The purpose of this paper is to compare the fire evacuation plan and preparation at the underground train stations in the different countries. The methodology for this study was using the extended questionnaire survey to investigate the Rapid Rail Sdn Bhd, Malaysia's fire safety plan and preparation at the underground train stations. There were four sections in the questionnaire which included (i) background of the respondents, (ii) the details on the train stations, safety instruction and fire evacuation exercises (iii) technical systems, installation and equipment at the underground stations and (iv) procedures and technical changes related to fire safety that had been applied by the operators. Previously, the respondents from the different train operator services in the developed countries had completed the questionnaires. This paper extends the response from the Rapid Rail Sdn Bhd to compare the emergency procedures and preparation for fire event with the developed countries. As a result, this study found that the equipment and facilities that provided at the underground train stations that operated by Rapid Rail are relevant for fire safety procedures and needs. The main advantage for Rapid Rail is the underground stations were designed with two or more entrances/exits that may perform better evacuation compare to one main entrance/exit train stations in the other developed countries.

  19. Thin-layer boilover in diesel-oil fires: Determining the increase of thermal hazards and safety distances

    Ferrero, Fabio; Munoz, Miguel; Arnaldos, Josep

    2007-01-01

    A study of the effects of thin-layer boilover on large hydrocarbon fires was carried out. In the experiments, diesel-oil was burned in pools with diameters ranging from 1.5 to 6 m. Previous models used to predict emissive power during the stationary state were analysed and successively modified in order to accurately predict thermal hazard during the water ebullition phase. It was discovered that the increase in emissive power during thin-layer boilover is greater when the pool diameter is smaller. Furthermore, the required increases in safety distances in the case of accidents involving this dangerous phenomenon are provided

  20. Technical report on design base events related to the safety assessment of a Low-level Waste Storage Facility (LWSF)

    Karino, Motonobu; Uryu, Mitsuru; Miyata, Kazutoshi; Matsui, Norio; Imamoto, Nobuo; Kawamata, Tatsuo; Saito, Yasuo; Nagayama, Mineo; Wakui, Yasuyuki

    1999-07-01

    The construction of a new Low-level Waste Storage Facility (LWSF) is planned for storage of concentrated liquid waste from existing Low-level Radioactive Waste Treatment Facility in Tokai Reprocessing Plant of JNC. An essential base for the safety designing of the facility is correctly implemented the adoption of the defence in depth principle. This report summarized criteria for judgement, selection of postulated events, major analytical conditions for anticipated operational occurrences and accidents for the safety assessment and evaluation of each event were presented. (Itami, H.)

  1. Advanced fire prevention techniques for ITER-INDIA laboratory building, IPR

    Modi, D.V.; Channa Reddy, D.

    2016-01-01

    Just as air and water, survival of human life without fire is unimaginable. However, fire can be a boon as well as a bane. The ability to control the use of fire is an art towards improved industrial development. The same phenomenon is also applicable for research and development sector. Fire Safety is a key issue for any kind of research laboratories. Fire hazards in laboratories arise from the storage and use of flammable materials and electrical installations and from hazardous operations carried out there. The risk of damage due to fire depends on the combustible available, their physical arrangement, the geometry of the building, likelihood of the ignition, etc. The risk is also controlled by the fire protection measures in place, which relate to both fire prevention and fire control. (author)

  2. Radioactive Solid Waste Storage and Disposal at Oak Ridge National Laboratory, Description and Safety Analysis

    Bates, L.D.

    2001-01-30

    Oak Ridge National Laboratory (ORNL) is a principle Department of Energy (DOE) Research Institution operated by the Union Carbide Corporation - Nuclear Division (UCC-ND) under direction of the DOE Oak Ridge Operations Office (DOE-ORO). The Laboratory was established in east Tennessee, near what is now the city of Oak Ridge, in the mid 1940s as a part of the World War II effort to develop a nuclear weapon. Since its inception, disposal of radioactively contaminated materials, both solid and liquid, has been an integral part of Laboratory operations. The purpose of this document is to provide a detailed description of the ORNL Solid Waste Storage Areas, to describe the practice and procedure of their operation, and to address the health and safety impacts and concerns of that operation.

  3. Accident safety analysis for 300 Area N Reactor Fuel Fabrication and Storage Facility

    Johnson, D.J.; Brehm, J.R.

    1994-01-01

    The purpose of the accident safety analysis is to identify and analyze a range of credible events, their cause and consequences, and to provide technical justification for the conclusion that uranium billets, fuel assemblies, uranium scrap, and chips and fines drums can be safely stored in the 300 Area N Reactor Fuel Fabrication and Storage Facility, the contaminated equipment, High-Efficiency Air Particulate filters, ductwork, stacks, sewers and sumps can be cleaned (decontaminated) and/or removed, the new concretion process in the 304 Building will be able to operate, without undue risk to the public, employees, or the environment, and limited fuel handling and packaging associated with removal of stored uranium is acceptable.

  4. Accident safety analysis for 300 Area N Reactor Fuel Fabrication and Storage Facility

    Johnson, D.J.; Brehm, J.R.

    1994-01-01

    The purpose of the accident safety analysis is to identify and analyze a range of credible events, their cause and consequences, and to provide technical justification for the conclusion that uranium billets, fuel assemblies, uranium scrap, and chips and fines drums can be safely stored in the 300 Area N Reactor Fuel Fabrication and Storage Facility, the contaminated equipment, High-Efficiency Air Particulate filters, ductwork, stacks, sewers and sumps can be cleaned (decontaminated) and/or removed, the new concretion process in the 304 Building will be able to operate, without undue risk to the public, employees, or the environment, and limited fuel handling and packaging associated with removal of stored uranium is acceptable

  5. Safety analysis of LWR irradiated fuel element pool storages before reprocessing

    Lefort, G.; Leclerc, J.; Hoffman, A.; Frejaville, C.; Domage, M.

    1984-01-01

    The protection of operators and environment requires imperatively that the safety must be taken into account as early as the design of the pools takes place and working conditions are defined. The analysis of criticality, irradiation, contamination, external or internal aggression hazards... allows to draw the main constraints which must be retained in the sizing of these pools: the criticality risk needs distances between fuel elements which results in a not very good utilization of the available area which leads to the utilization of neutron shieldings or requires a safe knowledge of the fuel elements burn up; the irradiation and contamination risks require a special quality of the pool water (temperature, activity, purity...) a good tightness of the basins to locate and to isolate the dubions fuel elements; the external or internal aggression risks such as earthquakes, missiles or loads drops, explosion, imply the civil engineering and involve the use of special technical devices. A brief presentation of the pool storages of the next UP2-800 and UP3 A reprocessing plants allows to show how the requirement drawn by safety analysis have been enforced, while carrying out civil engineering works without equivalent in the world, in this field. The foreseeable evolution of the uranium enrichment rate and burn-up of next PWR fuel elements have an effect upon the risk evaluations; a device apparatus, developed in CEA, for the measurement of burn up and cooling time is presented. At least, a short presentation of the mechanical structure durability studies of the reception and storage spent fuels installations are allowed to improve our knowledge in working conditions and in case of serious accidents

  6. Technology Development for Integrated Safety Test of Spent Nuclear Fuel Transportation and Storage System

    Seo, Kiseog; Seo, J. S.; Lee, J. C.

    2012-05-01

    A dedicated review on the U. S. NRC Regulation 10 CFR Part 72 and regulatory guide NUREG/1536 has been performed. The safety requirements for spent nuclear fuel dry storage cask are analyzed and summarized in structural, thermal, shielding, criticality, materials, tests and maintenance aspects. Also a guideline for preparing the safety analysis report is provided. The heat flow analysis was performed by varying the dimensions of the heat flow test facility. From the heat flow analysis for the test facility, as the test facility became test facility. From the heat flow analysis for the test facility, as the test facility became bigger; the thermal effect became smaller. Therefore, the dimensions of the heat flow test facility was designed with 5m Χ 5m Χ 6m(H). Analyses of heat transfer characteristics and mechanism for spent PWR fuel assemblies, option study for production of the effective thermal conductivity and option study for effective thermal conductivity test have been performed to obtain the basic data for production of the effective thermal conductivity. It became clear that the diffusion coefficient of chloride ion of concrete remarkably increases along with the temperature rise, and that there is a linear relation between the logarithm values of the diffusion coefficients and the reciprocal of the temperature. It is understood to be able to express the temperature dependency of the diffusion coefficient roughly by an Arrhenius equation as the velocity coefficient is provided as the diffusion coefficient. The specifications and characteristics of storage facilities under operation including dual purpose casks were investigated. Components subject to material degradation were examined. Based on literature survey, investigating a drop analysis incorporating with material degradation, the basic data to develop an analysis methodology was obtained

  7. Safety assessment of a dry storage container drop into irradiated fuel bays

    Parlatan, Y.; Oh, D.; Arguner, D.; Lei, Q.M.; Kulpa, T.; Bayoumi, M.H.

    2004-01-01

    In Pickering nuclear stations, Dry Storage Containers (DSCs) are employed to transfer used (irradiated) fuel from an irradiated fuel bay to a dry storage facility for interim storage. Each DSC is wet-loaded in the bay water with 4 fuel modules containing up to a total of 384 used fuel bundles that have been out of the reactor core for at least 10 years. Once the DSC is fully loaded, the crane in the bay raises the DSC for spray-wash such that the bottom of the DSC is never more than 2 m above the bay water surface. This paper presents a safety assessment of consequences of an unlikely event that a fully loaded DSC is accidentally dropped into an irradiated fuel bay from the highest possible elevation. Experiments and analyses performed elsewhere show that the DSC drop-generated shock waves will not threaten the structural integrity of an irradiated fuel bay. Therefore, this assessment only assesses the potential damage to the spent fuel bundles in the bay due to pressure transients generated by an accidental DSC drop. A bounding estimate approach has been used to calculate the upper limit of the pressure pulse and the resulting static and dynamic stresses on the fuel sheath. The bounding calculations and relevant experimental results demonstrate that an accidental drop of a fully loaded DSC into an irradiated fuel bay will not cause additional failures of the main fuel inventories stored in modules in the bay water, thus no consequential release of fission products into the bay water. (author)

  8. An Assessment of Hydrological Safety for the Guri Underground Oil Storage Facility

    Kim, Geon Young; Kim, Kyung Su; Koh, Yong Kwon; Bae, Dae Seok; Park, Kyung Woo; Ji, Sung Hoon; Ryu, Ji Hoon

    2009-08-15

    Hydrological and geochemical analysis of the various kinds of water including observation borehole groundwater was carried out for the assessment of the hydrological safety of the underground oil storage cavern and the potentiality of mineralogical and microbiological clogging was estimated. There was no distinct chemical difference in the various kinds of water. All kinds of water are undersaturated with the calcite which is the major clogging mineral. Most water samples have low Fe and Mn concentrations. However, they are saturated or oversaturated with the iron-oxide/hydroxide minerals and have high dissolved oxygen contents which softiies the possibility of clogging by the iron-oxide/hydroxide minerals as a long-term aspect. Statistical analysis shows the degree of mineral precipitation or dissolution is mainly controlled by pH, Eh and DO of water samples. Because the slime forming bacteria ate dominant microbe in several observation boreholes, the clogging can be caused by it as a long-term aspect. In addition, the possibility of clogging can be increased if the microbial effect is combined with the mineralogical effect such as iron oxide/hydroxide minerals for the possibility of clogging. Therefore, the systematic and long-term program for the assessment of clogging is required for the safe operation of underground oil storage cavern.

  9. An Assessment of Hydrological Safety for the Guri Underground Oil Storage Facility

    Kim, Geon Young; Kim, Kyung Su; Koh, Yong Kwon; Bae, Dae Seok; Park, Kyung Woo; Ji, Sung Hoon; Ryu, Ji Hoon

    2009-08-01

    Hydrological and geochemical analysis of the various kinds of water including observation borehole groundwater was carried out for the assessment of the hydrological safety of the underground oil storage cavern and the potentiality of mineralogical and microbiological clogging was estimated. There was no distinct chemical difference in the various kinds of water. All kinds of water are undersaturated with the calcite which is the major clogging mineral. Most water samples have low Fe and Mn concentrations. However, they are saturated or oversaturated with the iron-oxide/hydroxide minerals and have high dissolved oxygen contents which softiies the possibility of clogging by the iron-oxide/hydroxide minerals as a long-term aspect. Statistical analysis shows the degree of mineral precipitation or dissolution is mainly controlled by pH, Eh and DO of water samples. Because the slime forming bacteria ate dominant microbe in several observation boreholes, the clogging can be caused by it as a long-term aspect. In addition, the possibility of clogging can be increased if the microbial effect is combined with the mineralogical effect such as iron oxide/hydroxide minerals for the possibility of clogging. Therefore, the systematic and long-term program for the assessment of clogging is required for the safe operation of underground oil storage cavern

  10. Consideration on the partial moderation in criticality safety analysis of LWR fresh fuel storage

    Tanaka, S.; Tanimoto, R.; Suzuki, K.; Ishitobi, M.

    1987-01-01

    In criticality safety analyses of fuel fabrication facilities, neutron effective multiplication factor (k eff ) of a storage vault has been calculated assuming ''partial moderation'' in whole space (hereafter reffered to as unlimited partial moderation). Where the enrichment of fuels to be stored is about 3.5 % or less, calculated k eff is usually low enough to show subcriticality even in unlimited partial moderation. However, it is scheduled to elevate LWR fuels enrichment for economical higher burnup and the unlimited partial moderation would require to introduce neutron absorbers to maintain subcriticality. It is clear that this causes economical disadvantages, and hence we reconsidered this assumption to avoid such a condition. Reconsideration of the unlimited partial moderation was carried out in following steps. (1) Water quantity to be assumed in atmosphere to obtain criticality was revealed too much to realize. (2) Typical realistic water quantity in atmosphere was estimated to apply as an alternative assumption. (3) A fresh fuel assembly storage was chosen as a model array and calculations with lattice code WIMS-D 1 and Monte Calro code KENO-IV 2 were performed to compare new alternative assumption with the unlimited one. As results of the above calculations, maximum k eff of the array under the new assumption was remarkably reduced to the value less than 0.95 though the maximum k eff under the unlimited one was higher than 1.0. (author)

  11. Electronic firing systems and methods for firing a device

    Frickey, Steven J [Boise, ID; Svoboda, John M [Idaho Falls, ID

    2012-04-24

    An electronic firing system comprising a control system, a charging system, an electrical energy storage device, a shock tube firing circuit, a shock tube connector, a blasting cap firing circuit, and a blasting cap connector. The control system controls the charging system, which charges the electrical energy storage device. The control system also controls the shock tube firing circuit and the blasting cap firing circuit. When desired, the control system signals the shock tube firing circuit or blasting cap firing circuit to electrically connect the electrical energy storage device to the shock tube connector or the blasting cap connector respectively.

  12. Overview of Development and Deployment of Codes, Standards and Regulations Affecting Energy Storage System Safety in the United States

    Conover, David R.

    2014-08-22

    This report acquaints stakeholders and interested parties involved in the development and/or deployment of energy storage systems (ESS) with the subject of safety-related codes, standards and regulations (CSRs). It is hoped that users of this document gain a more in depth and uniform understanding of safety-related CSR development and deployment that can foster improved communications among all ESS stakeholders and the collaboration needed to realize more timely acceptance and approval of safe ESS technology through appropriate CSR.

  13. Research on consequence analysis method for probabilistic safety assessment of nuclear fuel facilities (4). Investigation of safety evaluation method for fire and explosion incidents

    Abe, Hitoshi; Tashiro, Shinsuke; Ueda, Yoshinori

    2010-01-01

    A special committee on 'Research on the analysis methods for accident consequence of nuclear fuel facilities (NFFs)' was organized by the Atomic Energy Society of Japan (AESJ) under the entrustment of Japan Atomic Energy Agency (JAEA). The committee aims to research on the state-of-the-art consequence analysis method for Probabilistic Safety Assessment (PSA) of NFFs, such as fuel reprocessing and fuel fabrication facilities. The objective of this research is to obtain the useful information related to the establishment of quantitative performance objectives and to risk-informed regulation through qualifying issues needed to be resolved for applying PSA to NFFs. The research activities of the committee were mainly focused on the analysis method of consequences for postulated accidents with potentially large consequences in NFFs, e.g., events of criticality, spill of molten glass, hydrogen explosion, boiling of radioactive solution, and fire (including rapid decomposition of TBP complexes), resulting in the release of radio active materials into the environment. The results of the research were summarized in a series of six reports, which consist of a review report and five technical ones. In this technical report, the research results about basic experimental data and the method for safety evaluation of fire and explosion incidents were summarized. (author)

  14. Specification of materials Data for Fire Safety Calculations based on ENV 1992-1-2

    Hertz, Kristian Dahl

    1997-01-01

    of constructions of any concrete exposed to any time of any fire exposure can be calculated.Chapter 4.4 provides information on what should be observed if more general calculation methods are used.Annex A provides some additional information on materials data. This chapter is not a part of the code......The part 1-2 of the Eurocode on Concrete deals with Structural Fire Design.In chapter 3, which is partly written by the author of this paper, some data are given for the development of a few material parameters at high temperatures. These data are intended to represent the worst possible concrete...... to experience form tests on structural specimens based on German siliceous concrete subjected to Standard fire exposure until the time of maximum gas temperature.Chapter 4.3, which is written by the author of this paper, provides a simplified calculation method by means of which the load bearing capacity...

  15. SMiRT 23. 14{sup th} international seminar on fire safety in nuclear power plants and installations

    Roewekamp, Marina (ed.) [Gesellschaft fuer Anlagen- und Reaktorsicherheit (GRS) gGmbH, Koeln (Germany); Berg, Heinz-Peter [Bundesamt fuer Strahlenschutz, Salzgitter (Germany)

    2015-12-15

    In the frame of the project 3614R01575 funded by the German Ministry for the Environment, Nature Conservation, Building and Nuclear Safety (Bundesministerium fuer Umwelt, Naturschutz, Bau und Reaktorsicherheit, BMUB) the meanwhile fourteenth international seminar on ''Fire Safety in Nuclear Power Plants and Installations'' has been conducted as P ost-Conference Seminar of the 23{sup rd} International Conference on Structural Mechanics In Reactor Technology (SMiRT 23) in Salford, United Kingdom in August 2015. The following seminar proceedings contain the entire twenty-one technical contributions to the two day s seminar with in total fifty-five participants from ten countries in Asia, Europe and America.

  16. Jefferson Proving Ground, South of the Firing Line Health and Safety Plan, Volume 4

    1992-01-01

    .... The purpose of this Site Health and Safety Plan (SHSP) is to assign SECD personnel health and safety responsibilities, to prescribe mandatory operating procedures, and to establish personal-protective-equipment (PPE...

  17. Efficient cascaded parameter scan approach for studying top-off safety in storage rings

    Yongjun Li

    2011-03-01

    Full Text Available We introduce a new algorithm, which we call the cascaded parameter scan method, to efficiently carry out the scan over magnet parameters in the safety analysis for top-off injection in synchrotron radiation storage rings. In top-off safety analysis, one must track particles populating phase space through a beam line containing magnets and apertures and clearly demonstrate that, for all possible magnet settings and errors, all particles are lost on scrapers within the properly shielded region. In the usual approach, if one considers m magnets and scans each magnet through n setpoints, then one must carry out n^{m} tracking runs. In the cascaded parameter scan method, the number of tracking runs is reduced to n×m. This reduction of exponential to linear dependence on the number of setpoints n greatly reduces the required computation time and allows one to more densely populate phase space and to increase the number n of setpoints scanned for each magnet.

  18. Safety analysis and inventory control of transuranic and low-level waste in common storage

    Porten, D.R.; Bonner, A.L.; Joyce, J.P.

    1993-01-01

    This paper describes a methodology developed For the inventory control of low-level waste (LLW) and transuranic (TRU) waste, when both are stored in the same location, and both contribute to an inventory constrained by safety considerations. Development of the method arose from the necessity to make safety analysis calculations for the addition of LLW, in quantities greater than existing inventory limits would allow when stored with TRU waste, in the Hanford Central Waste Complex (CWC)-Ensuring that the dose consequences of credible releases are maintained at low-hazard limits or less, was used to allow greater than Type A quantities of LLW into the CWC. Basically, what happens is the original limited amount of TRU allowed is reduced by some equivalent amount of LLW introduced. The total quantity of TRU, and LLW in excess of Type A quantities, must be administratively maintained via curie equivalency Factors to ensure operation as a low-hazard Facility. The ''equivalency'' between TRU and LLW proposed here is specific only to the CWC, but the methodology can be used for other specific applications, such as TRU and LLW storage or handling facilities where inventory limits must be enforced or where a simplified inventory system is required

  19. Mathematical models as tools for probing long-term safety of CO2 storage

    Pruess, Karsten; Birkholzer, Jens; Zhou, Quanlin

    2009-02-01

    Subsurface reservoirs being considered for storing CO{sub 2} include saline aquifers, oil and gas reservoirs, and unmineable coal seams (Baines and Worden, 2004; IPCC, 2005). By far the greatest storage capacity is in saline aquifers (Dooley et al., 2004), and our discussion will focus primarily on CO{sub 2} storage in saline formations. Most issues for safety and security of CO{sub 2} storage arise from the fact that, at typical temperature and pressure conditions encountered in terrestrial crust, CO{sub 2} is less dense than aqueous fluids. Accordingly, CO{sub 2} will experience an upward buoyancy force in most subsurface environments, and will tend to migrate upwards whenever (sub-)vertical permeable pathways are available, such as fracture zones, faults, or improperly abandoned wells (Bachu, 2008; Pruess, 2008a, b; Tsang et al., 2008). CO{sub 2} injection will increase fluid pressures in the target formation, thereby altering effective stress distributions, and potentially triggering movement along fractures and faults that could increase their permeability and reduce the effectiveness of a caprock in containing CO{sub 2} (Rutqvist et al., 2008; Chiaramonte et al., 2008). Induced seismicity as a consequence of fluid injection is also a concern (Healy et al., 1968; Raleigh et al., 1976; Majer et al., 2007). Dissolution of CO{sub 2} in the aqueous phase generates carbonic acid, which may induce chemical corrosion (dissolution) of minerals with associated increase in formation porosity and permeability, and may also mediate sequestration of CO{sub 2} as solid carbonate (Gaus et al., 2008). Chemical dissolution of caprock minerals could promote leakage of CO{sub 2} from a storage reservoir (Gherardi et al., 2007). Chemical dissolution and geomechanical effects could reinforce one another in compromising CO{sub 2} containment. Additional issues arise from the potential of CO{sub 2} to mobilize hazardous chemical species (Kharaka et al., 2006), and from migration of

  20. Chemical research projects office functions accomplishments programs. [applied research in the fields of polymer chemistry and polymeric composites with emphasis on fire safety

    Heimbuch, A. H.; Parker, J. A.

    1975-01-01

    Basic and applied research in the fields of polymer chemistry, polymeric composites, chemical engineering, and biophysical chemistry is summarized. Emphasis is placed on fire safety and human survivability as they relate to commercial and military aircraft, high-rise buildings, mines and rapid transit transportation. Materials systems and other fire control systems developed for aerospace applications and applied to national domestic needs are described along with bench-scale and full-scale tests conducted to demonstrate the improvements in performance obtained through the utilization of these materials and fire control measures.

  1. Regulatory analysis for the resolution of generic issue 57: Effects of Fire Protection System Actuation on Safety-Related Equipment

    Woods, H.W.

    1993-10-01

    Actuation of Fire Protection Systems (FPS) in Nuclear Power Plants have resulted in adverse interactions with equipment important to safety. Precursor operational experience has shown that 37% of all FPS actuations damaged some equipment, and 20% of all FPS actuations have resulted in a plant transient and reactor trip. On an average 0.17 FPS actuations per reactor year have been experienced in nuclear power plants in this country. This report presents the regulatory analysis for GI-57, ''Effects of Fire Protection System Actuation on Safety-Related Equipment''. The risk reduction estimates, cost/benefit analyses, and other insights gained during this effort have shown that implementation of the recommendations contained in this report can significantly reduce risk, and that these improvements can be warranted in accordance with the backfit rule, 10 CFR 50.109(a)(3). However, plant specific analyses are required in order to identify such improvements. Generic analyses can not serve to identify improvements that could be warranted for individual, specific plants. Plant specific analyses of the type needed for this purpose are underway as part of the Individual Plant Examination of External Events (IPEEE) program

  2. IINFLUENCE OF FREEZING AND PROLONGED STORAGE OF EXPRESSED BREAST MILK ON ITS NUTRITIVE, BIOLOGICAL VALUES AND MICROBIOLOGICAL SAFETY

    O. L. Lukoyanova

    2011-01-01

    Full Text Available Evaluation of prolonged storage of breast milk safety for nutrition of newborns remains actual problem of modern nutritiology. Objectives: to evaluate an influence of freezing and prolonged storage of expressed breast milk on its nutritive, biological values and microbiological safety. Methods: samples of expressed breast milk (native samples and after 1 and 3 months of storage in containers Philips AVENT in t -18°С were analyzed; levels of secretory IgA, lysozyme, transforming growth factor (TGF β1, potassium, calcium, magnesium, pH, buffer capacity and bacterial cells were detected. Results: there is no statistically significant influence of low temperature and prolonged storage of expressed breast milk on levels of secretory IgA, lysozyme, TGF β1 and bacterial cells. Potassium and calcium levels significantly decreased (on about 10% and 20% accordingly, pH increased, and buffer capacity of milk lowered after freezing during 3 months. Conclusion: children’s feeding with native and expressed breast milk defrosted after 3 months of storage is equal in nutritive and biological values and microbiological safety.

  3. An Actuator Control Unit for Safety-Critical Mechatronic Applications with Embedded Energy Storage Backup

    Sergio Saponara

    2016-03-01

    Full Text Available This paper presents an actuator control unit (ACU with a 450-J embedded energy storage backup to face safety critical mechatronic applications. The idea is to ensure full operation of electric actuators, even in the case of battery failure, by using supercapacitors as a local energy tank. Thanks to integrated switching converter circuitry, the supercapacitors provide the required voltage and current levels for the required time to guarantee actuator operation until the system enters into safety mode. Experimental results are presented for a target application related to the control of servomotors for a robotized prosthetic arm. Mechatronic devices for rehabilitation or assisted living of injured and/or elderly people are available today. In most cases, they are battery powered with lithium-based cells, providing high energy density and low weight, but at the expense of a reduced robustness compared to lead-acid- or nickel-based battery cells. The ACU of this work ensures full operation of the wearable robotized arm, controlled through acceleration and electromyography (EMG sensor signals, even in the case of battery failure, thanks to the embedded energy backup unit. To prove the configurability and scalability of the proposed solution, experimental results related to the electric actuation of the car door latch and of a robotized gearbox in vehicles are also shown. The reliability of the energy backup device has been assessed in a wide temperature range, from −40 to 130 °C, and in a durability test campaign of more than 10,000 cycles. Achieved results prove the suitability of the proposed approach for ACUs requiring a burst of power of hundreds of watts for only a few seconds in safety-critical applications. Alternatively, the aging and temperature characterizations of energy backup units is limited to supercapacitors of thousands of farads for high power applications (e.g., electric/hybrid propulsion and with a temperature range limited to

  4. Using GIS to evaluate a fire safety program in North Carolina.

    Dudley, Thomas; Creppage, Kathleen; Shanahan, Meghan; Proescholdbell, Scott

    2013-10-01

    Evaluating program impact is a critical aspect of public health. Utilizing Geographic Information Systems (GIS) is a novel way to evaluate programs which try to reduce residential fire injuries and deaths. The purpose of this study is to demonstrate the application of GIS within the evaluation of a smoke alarm installation program in North Carolina. This approach incorporates national fire incident data which, when linked with program data, provides a clear depiction of the 10 years impact of the Get Alarmed, NC! program and estimates the number of potential lives saved. We overlapped Get Alarmed, NC! program installation data with national information on fires using GIS to identify homes that experienced a fire after an alarm was installed and calculated potential lives saved based on program documentation and average housing occupancy. We found that using GIS was an efficient and quick way to match addresses from two distinct sources. From this approach we estimated that between 221 and 384 residents were potentially saved due to alarms installed in their homes by Get Alarmed, NC!. Compared with other program evaluations that require intensive and costly participant telephone surveys and/or in-person interviews, the GIS approach is inexpensive, quick, and can easily analyze large disparate datasets. In addition, it can be used to help target the areas most at risk from the onset. These benefits suggest that by incorporating previously unutilized data, the GIS approach has the potential for broader applications within public health program evaluation.

  5. “Use of fire extinguishers” course: A hot tip for your safety!

    The Safety Training Team

    2013-01-01

    The “Use of fire extinguishers – live exercises” course was introduced in conjunction with the Fire and Rescue Service and the HSE Unit at the start of 2012. Since then, more than 800 people have been trained in the use of fire extinguishers.   Photo: Vanessa Bandier. This course is aimed at all members of the CERN personnel. It takes place at the Prévessin training centre, lasts an hour and a half and consists of a theoretical part and a practical part with a role-play exercise in the simulator. The course can be taken in French or English. Here are some examples of comments received from people who have taken the course: “Excellent training session, very useful, especially the practical part. I’m no longer afraid to use a fire extinguisher.” “I was impressed with the quality of the installations used for the training. I didn’t expect every participant to be able to practise dealing with an emergency...

  6. Safety - Multiple Languages

    ... bosanski (Bosnian) PDF Fire Safety at Home - English MP3 Fire Safety at Home - bosanski (Bosnian) MP3 Fire Safety at Home - English MP4 Fire Safety ... Burmese) PDF Home Safety Checklist - myanma bhasa (Burmese) MP3 Minnesota Department of Health Chinese, Simplified (Mandarin dialect) ( ...

  7. Fire and fire extinguishment in silos. An experimental study[Storage of wood fuel pellets]; Brand och brandslaeckning i siloanlaeggningar. En experimentell studie

    Persson, Henry; Blomqvist, Per; Zhenghua Yan

    2007-01-15

    A series of four tests have been conducted with wood pellets stored in a reduced size silo. The tests were conducted in order to increase the knowledge on fire development, detection and extinction technique in silo fires. The project originated from a pre-study on the extinction of silo fires made for the Swedish Rescue Service Agency (SRV). The test silo was built of concrete rings, had a diameter of 1 m, and a height of almost 6 m, which gave a volume of 4.4 m{sup 3}. The silo was filled with wood pellets up to a height of 5 m. A local auto ignition was imitated by a coiled heating wire placed in the pellet bulk centrally in the silo and a self sustaining pyrolysis zone was established within one hour. The silo was instrumented with almost 100 thermocouples as a mean to follow the development of the pyrolysis zone and later the efficiency of the extinguishment. Gas analyses were further made, both in the top of the silo, and at four different levels in the pellet bulk. After 30 hours the extinguishment was initiated using nitrogen (N{sub 2}) and carbon dioxide (CO{sub 2}), respectively. The gas was injected into the bottom of the silo. Two tests were also conducted where gas injection was combined foam application in the top of the silo. The tests showed that the pyrolysis zone preferably spreads downwards in the silo, while moisture and pyrolysis gases form a wave that slowly spreads upwards. It was difficult to detect the fire before the main 'gas wave' reached the pellet surface in the silo top, and detection time was about 20 hours in these tests. The spread of the pyrolysis zone, downward, was even slower. The slow development is probably an explanation of why real silo fires often are rather extensive once discovered. Inerting the silo with either nitrogen or carbon dioxide worked out well in the tests. The gas must be in gas phase and slowly introduced into the silo, as close to the bottom as possible. An efficient extinction implies an air

  8. Effects of gamma irradiation on microbial safety and quality of stir fry chicken dices with hot chili during storage

    Chen, Qian; Cao, Mei; Chen, Hao; Gao, Peng; Fu, Yi; Liu, Mianxue; Wang, Yan; Huang, Min

    2016-01-01

    The purpose of this study was to investigate effects of irradiation with different doses on microbial safety, sensory quality and protein content of ready-to-eat stir fry chicken dices with hot chili (FCC) during one year storage. Fresh chicken meat was cut into small dices and fried at approximately 180 °C for 10 min for preparation of FCC samples. The samples were vacuum-packaged and gamma irradiated at 10, 20, 30 and 40 kGy. The results suggest that irradiation with the doses of 10 and 20 kGy could ensure microbiological safety of the samples without deterioration of sensory quality. Microbial counts, sensory qualities and protein contents of the samples were investigated during one year storage. No viable cells were observed and the samples were completely sterilized. Sensory qualities showed no significant difference after irradiated at the doses of 10 and 20 kGy during the storage period. Protein contents were also not affected by irradiation at the same doses. Our results indicate that gamma irradiation of 10 and 20 kGy are effective to maintain shelf stability of ready-to-eat FCC products with microbial safety, sensory quality and nutritional value. - Highlights: • Microbial safety and sensory quality of the FCC are ensured by gamma irradiation. • No viable cells in the irradiated FCC are detected during one year storage. • Sensory quality of the irradiated FCC is not changed during one year storage. • Protein content of the FCC is not affected by irradiation during one year storage.

  9. The Aube Storage Centre. Information report on nuclear safety and radiation protection for 2014 - Annual report 2014

    2014-06-01

    After a presentation of the installations of CSA (Aube Storage Centre), its equipment, its exploitation (deliveries, storage, compacting unit, injection unit, storage works), works performed and highlights in 2014, and perspectives of evolution for 2015 and 2016, this report presents the measures regarding nuclear safety: safety principles, technical measures to meet objectives, inspections performed by the Nuclear Safety Authority (ASN), and quality management. The next part presents measures regarding measures for radiation protection and safety: staff dosimetry (measurements results and evolutions), safety exercise. It outlines that no important incident occurred, and described three minor events which have been declared to the ASN. The next part addresses actions related to the control of the environment and of releases: water management, presentation and discussion of the main results of radiological measurements (rainfalls, air, brook waters, sediments, underground waters, radiation at the edge of the centre, ground vegetal, food chain, aquatic ecosystems), physical-chemical control of waters, actions for the protection of the environment. The report then gives an overview of the management of radioactive and conventional wastes produced by the Centre. The last part indicates and comments actions related to transparency and information (they may concern the public, local authorities, institutions, or media): visits, conferences, exhibitions, animations, partnerships, publications

  10. Safety requirements of the BMU to be met in final storage of heat-producing waste: An evaluation

    Thomauske, Bruno

    2009-01-01

    On August 12, 2008, The German Federal Ministry for the Environment, Nature Conservation, and Nuclear Safety (BMU) published a draft of July 29, 2008 of the ''Safety Requirements to Be Met in Final Storage of Heat-producing Radioactive Waste.'' As announced by the BMU, these safety requirements are to bring up to the state of the art the safety criteria of 1983. Over a couple of years, efforts had been made to adapt the criteria to the internationally accepted standard as demanded by the Advisory Committees on Reactor Safeguards (RSK) and Radiation Protection (SSK). There is no waste management concept underlying the safety requirements. As a consequence, the draft should be withdrawn by the Federal Ministry for the Environment and replaced by a version revised from scratch and offering assured quality. (orig./GL)

  11. Pilot-benchmarking of the WENRA safety reference levels for the spent fuel intermediate storage facility Ahaus

    Lorenz, Bernd; Roeder, Markus; Brandt, Klaus-Dieter

    2008-01-01

    Full text: The Western European Nuclear Regulator's Association (WENRA) has 2007 issued the draft of the 'Waste and Spent Fuel Storage Safety Reference Levels'. The objective of WENRA is to strive for a harmonized safety level of nuclear facilities within the European Community and these Reference Levels are a benchmark method to demonstrate the achieved level for the regulatory system and the implementation as well. Safety Reference Levels exist at the moment for Reactor Safety, Waste Storage and Decommissioning in different stages of development. ENISS, the European Nuclear Installations Safety Standards Initiative, a FORATOM based special organisation of nuclear operators, has discussed these Safety Reference Levels very intensively with WENRA and the agreement was to make a implementation benchmark-exercise for the storage facilities before the authorities finally agree on the Reference Levels. This benchmark was scheduled for the year 2008. Because of the special situation in Germany where a large number of storage facilities is in operation the German authorities felt that it would be useful to initiate a Pilot-Benchmark to get first results on the feasibility of the Reference Levels and the burden imposed to authorities and operators by these benchmark-exercises. GNS, a subsidiary company of the utilities, agreed to step into this process on a voluntary basis with its storage facility for spent fuel in Ahaus. The exercise was done in a very efficient way and in good co-operation between the authorities, local and federal, and the operator. The results in terms of safety assessments have been very satisfactory showing the high degree of safety. Although the facility was for the first time licensed already in 1987 the compliance with nearly all Reference Levels from 2007 could be demonstrated. It became also clear that newer facilities would fulfil the desired safety standard too. Nevertheless, in spite of the good results the exercise revealed some weak

  12. Tunnel fire dynamics

    Ingason, Haukur; Lönnermark, Anders

    2015-01-01

    This book covers a wide range of issues in fire safety engineering in tunnels, describes the phenomena related to tunnel fire dynamics, presents state-of-the-art research, and gives detailed solutions to these major issues. Examples for calculations are provided. The aim is to significantly improve the understanding of fire safety engineering in tunnels. Chapters on fuel and ventilation control, combustion products, gas temperatures, heat fluxes, smoke stratification, visibility, tenability, design fire curves, heat release, fire suppression and detection, CFD modeling, and scaling techniques all equip readers to create their own fire safety plans for tunnels. This book should be purchased by any engineer or public official with responsibility for tunnels. It would also be of interest to many fire protection engineers as an application of evolving technical principles of fire safety.

  13. Buildings exposed to fire

    1987-01-01

    The 24 lectures presented to the colloquium cover the following subject fields: (1) Behaviour of structural components exposed to fire; (2) Behaviour of building materials exposed to fire; (3) Thermal processes; (4) Safety related, theoretical studies. (PW) [de

  14. Evaluation of the influence of a postulated lubrication oil fire on safety related cables in the top shield platform of PFBR RCB by using FDS Code

    Mangarjuna Rao, P.; Jayasuriya, C.; Nashine, B.K.; Chellapandi, P.; Velusamy, K.

    2010-01-01

    Top deck of Prototype Fast Breeder Reactor (PFBR) primary system houses redundant safety related systems like Control and Safety Rod Drive Mechanisms (CSRDM), Diverse Safety Rod Drive Mechanism (DSRDM), subassembly outlet sodium temperature measurement system and central canal plug. These systems protrude out from the reactor through the Control Plug (CP), which is supported on the Top Shield (TS) of PFBR. Control and instrumentation signal cables and power cables of these safety related systems that are coming out from the CP are routed through Top Shield Platform (TSP, which is concentric with Reactor Vault (RV) at EL 34.1 m above the TS) to the peripheral local instrumentation control centers via the cable junction boxes supported on TS. Influence approach fire hazard analysis (FHA) has been carried out to evaluate the condition of redundant safety related cables under the scenario of a postulated oil fire in the TSP using Fire Dynamics Simulator code (FDS, Version 5). FDS is a computational fluid dynamics (CFD) based fire analysis code and it is developed by National Institute of Standards and Technology (NIST), USA. In this paper the details of the model developed and the results of the analysis carried out are discussed. In TSP, a postulated oil fire scenario with complete inventory of a primary sodium pump (PSP) lubrication oil leak (200 lt) has been considered at 30 m elevation on the TS. Computational model with the geometry of TSP and with other important structural components on TS like PSPs, intermediate heat exchangers (IHXs), large rotating plug (LRP), small rotating plug (SRP), CP and etc. has been developed along with a fire of 1800 kW/m 2 heat release rate in the vicinity of the PSP1. Numerical simulation has been carried out to evaluate this oil fire influence on the typical safety related cables routed at 34 m elevation. It has been found that the surface temperature of the cables that are routed directly above the fire only crosses the ignition

  15. Safety in connection with the request for approval of the installation alteration in the fuel reprocessing facilities of Power Reactor and Nuclear Fuel Development Corporation (report)

    1982-01-01

    A report to the Prime Minister by the Nuclear Safety Commission was presented concerning the safety in the installation alteration of the fuel reprocessing facilities, as PNC had requested its approval to the Prime Minister. The safety was confirmed. The items of examination on the safety made by the committee on Examination of Nuclear Fuel Safety of NSC were the aseismic design of liquid waste storage, uranium denitration facility, intermediate gate and radioactive solid waste storage; the criticality safety design of the denitration facility; the radiation shielding design of the liquid waste storage, denitration facility and solid waste storage; the function of radioactive material containment of the liquid waste storage and denitration facility; the radiation control in the liquid waste storage, denitration facility and solid waste storage; the waste management in the liquid waste storage and denitration facility; fire and explosion prevention in the liquid waste storage; exposure dose from the liquid waste storage and denitration facility. (Mori, K.)

  16. Effects of chilled-then-frozen storage (up to 52weeks) on lamb M. longissimus lumborum quality and safety parameters.

    Coombs, Cassius E O; Holman, Benjamin W B; Collins, Damian; Friend, Michael A; Hopkins, David L

    2017-12-01

    This study evaluated the effect of chilled followed by frozen storage on lamb quality and safety parameters. Experimental (n=360) M. longissimus lumborum (LL) were randomly sampled from the boning room of a commercial Australian abattoir, at 24 h post-mortem, and assigned to five chilled storage periods (0, 2, 4, 6 and 8 weeks) and six subsequent frozen storage periods (0, 4, 8, 12, 24 and 52 weeks). Upon completion of each storage treatment combination, corresponding LL were sub-sectioned and analysed for colour stability (0, 1, 2 and 3 days), shear force, fluid losses (purge, thaw and cooking losses), intramuscular fat content, sarcomere length, water activity and microbial load (lactic acid bacteria, Enterobacteriaceae sp., Brochothrix thermosphacta, Clostridium perfringens and Escherichia coli). LL stored chilled for 2-4 weeks prior to freezing presented superior results for shear force, display colour and low levels of spoilage microbes, correlating with good eating quality and safety following more than one year of frozen storage. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  17. Conceptual aspects of the safety evaluation of a project of complementary spent nuclear fuel dry storage unit

    Freitas, Rafaela da S. A.; Fontes, Gladson S., E-mail: rafaaelaandrade@hotmail.com, E-mail: gsfontes@hotmail.com [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil); Saldanha, Pedro L. C., E-mail: saldanha@cnen.gov.br [Comissão Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Based on the number of cycles and the amount of new fuel elements exchanged in the reactor cores at each cycle, the forecast for the exhaustion of the spent nuclear fuel pools of the Brazil plants has provision until 2021. As are still in the studies the availability of a long-term storage facility for spent fuel, the short-term solution will be the construction of the Complementary Storage Spent Nuclear Fuel Unit, it will build inside the site in Angra Plants. The dry cask is a method of storage in which the fuel elements of high-level radioactive waste are stored, such as spent nuclear fuel, which already cooled in the fuel pool for at least one year and up to ten years. The purpose of the present paper is to discuss a conceptual study of the safety analysis of a project of licensing of a Dry Storage Unit (DSU) with the objective of verifying the application of national and international criteria, requirements and standards. The safety analysis will make on the principles adopted by the US Nuclear USNRC and the standards adopted at CNEN for dry storage. The concept of installation, seismic, geological and other analysis will be approached for approval of the site to be installed at DSU, the approved permit for the construction and finally the external and internal events that may occur being incidents and / or accidents and which are The necessary mitigations if something occurs within a period of time. (author)

  18. Conceptual aspects of the safety evaluation of a project of complementary spent nuclear fuel dry storage unit

    Freitas, Rafaela da S. A.; Fontes, Gladson S.; Saldanha, Pedro L. C.

    2017-01-01

    Based on the number of cycles and the amount of new fuel elements exchanged in the reactor cores at each cycle, the forecast for the exhaustion of the spent nuclear fuel pools of the Brazil plants has provision until 2021. As are still in the studies the availability of a long-term storage facility for spent fuel, the short-term solution will be the construction of the Complementary Storage Spent Nuclear Fuel Unit, it will build inside the site in Angra Plants. The dry cask is a method of storage in which the fuel elements of high-level radioactive waste are stored, such as spent nuclear fuel, which already cooled in the fuel pool for at least one year and up to ten years. The purpose of the present paper is to discuss a conceptual study of the safety analysis of a project of licensing of a Dry Storage Unit (DSU) with the objective of verifying the application of national and international criteria, requirements and standards. The safety analysis will make on the principles adopted by the US Nuclear USNRC and the standards adopted at CNEN for dry storage. The concept of installation, seismic, geological and other analysis will be approached for approval of the site to be installed at DSU, the approved permit for the construction and finally the external and internal events that may occur being incidents and / or accidents and which are The necessary mitigations if something occurs within a period of time. (author)

  19. Proceedings of the research conference on post-accident waste management safety (RCWM2016) and the technical seminar on safety research for radioactive waste storage

    Motooka, Takafumi; Yamagishi, Isao

    2017-03-01

    Collaborative Laboratories for Advanced Decommissioning Science (CLADS) is responsible to promote international cooperation in the R and D activities on the decommissioning of Fukushima Daiichi Nuclear Power Station and to develop the necessary human resources. CLADS held the Research Conference on Post-accident Waste Management Safety (RCWM2016) on 7th November, 2016 and the Technical Seminar on Safety Research for Radioactive Waste Storage on 8th November, 2016. This report compiles the abstracts and the presentation materials in the above conference and seminar. (author)

  20. Safety analysis report for the mixed waste storage facility and portable storage units at the Idaho National Engineering Laboratory

    Peatross, R.

    1997-01-01

    The Mixed Waste Storage Facility (MWSF) including the Portable Storage Units (PSUs) is a government-owned contractor-operated facility located at the Idaho National Engineering Laboratory (INEL). Lockheed Martin Idaho Technologies Company (LMITCO) is the current operating contractor and facility Architect/Engineer as of September 1996. The operating contractor is referred to as open-quotes the Companyclose quotes or open-quotes Companyclose quotes throughout this document. Oversight of MWSF is provided by the Department of Energy Idaho Operations Office (DOE-ID). The MWSF is located in the Power Burst Facility (PBF) Waste Reduction Operations Complex (WROC) Area, approximately 10.6 km (6.6 mi) from the southern INEL boundary and 4 km (2.5 mi) from U.S. Highway 20

  1. Worker safety for occupations affected by the use, transportation and storage of radioactive and hazardous materials

    1994-07-01

    A study group under the auspices of the National Conference of State Legislatures (NCSL) Labor Committee and the High-level Radioactive Waste/Hazardous Materials Transportation Task Force examined worker protection and safety programs for occupations affected by the use, transportation and storage of radioactive and hazardous materials. Concern about the risks posed to people who live along spent nuclear fuel transportation routes has led to demands for redundant inspections of the transported spent fuel. It would also be prudent to examine the radiological risk to the inspectors themselves before state of federal regulations are promulgated which require redundant inspections. Other workers may also come close to a spent fuel cask during normal operations. The dose rate to which these inspectors and handlers are exposed is higher than the dose rate to which any other group is exposed during incident-free truck transportation and higher than the dose rate to the drivers when they are in the truck cab. This report consists of miscellaneous papers covering topics related to determining radiation doses to workers involved in the transport of radioactive materials

  2. The long term storage of radioactive waste: Safety and sustainability. A position paper of international experts

    NONE

    2003-06-01

    The purpose of the report is to reflect the currently prevailing views among experts in the field of radioactive waste storage and disposal. It is intended for use as a central and authoritative reference point for national discussions and policy papers. It is therefore potentially useful to national committees and bodies concerned with the management of radioactive waste. It may also be of value to concerned members of the public since it is written in language that should be comprehensible to the informed lay person. It was produced as a result of several meetings of experts in the first part of 2002. Since then, it has been reviewed by the international Waste Safety Standards Committee (WASSC), by the WASSC Subgroup on Principles and Criteria for the Disposal of Radioactive Waste at its meeting in October 2000 and by a technical committee convened specifically to review the paper at a meeting held in November 2002. Finally, the essential conclusions of the paper were presented to and discussed with participants to the International Conference on Issues and Trends in Radioactive Waste Management, held in Vienna in December 2002.

  3. The long term storage of radioactive waste: Safety and sustainability. A position paper of international experts

    2003-06-01

    The purpose of the report is to reflect the currently prevailing views among experts in the field of radioactive waste storage and disposal. It is intended for use as a central and authoritative reference point for national discussions and policy papers. It is therefore potentially useful to national committees and bodies concerned with the management of radioactive waste. It may also be of value to concerned members of the public since it is written in language that should be comprehensible to the informed lay person. It was produced as a result of several meetings of experts in the first part of 2002. Since then, it has been reviewed by the international Waste Safety Standards Committee (WASSC), by the WASSC Subgroup on Principles and Criteria for the Disposal of Radioactive Waste at its meeting in October 2000 and by a technical committee convened specifically to review the paper at a meeting held in November 2002. Finally, the essential conclusions of the paper were presented to and discussed with participants to the International Conference on Issues and Trends in Radioactive Waste Management, held in Vienna in December 2002

  4. The study of the installation of spent fuel interim storage facility from safety aspect point of view

    Djunaidi, Prayogo S.

    1999-01-01

    The installation of the ISFSF of the RSG-GAS has been come a cureneed, since the RSG-GAS has been operating for more than 10 years. The spent fuel stored in the reactor storage pool in creasing from time to time and therefore a long time storage is needed until the decommissioning of the reactor. The safety aspect related to the installation of the ISFSF has been studied, but the most important aspect are prevention of criticality of the spen fuel in the storage. The radiation dose must be less than that has been recommended by ICRP and the release of the radioactive material must be avoided . In this paper one of the safety aspects i.e. the radiological aspect is described, while the other aspects are referenced to safety analysis report of the facility. From the calculation it can be seen that in accident condition the total radiation dose received by the handling operator is 1.06 mSv and 1.6 mSv resulted from Kr-85 and 1-131. This is lower than the limitation recommended by the ICRP No. 60.1990. Verification for other safety aspect of the facility in still needed

  5. Fire safety of ETICS with wood fibreboards for multi-storey buildings – first research and development results

    Küppers Judith

    2016-01-01

    Full Text Available Wood fibreboards can serve as alternative sustainable insulation material for external thermal insulation component systems (ETICS. In Germany, the application of ETICS with wood fibreboards is restricted to low buildings. The restrictions are mainly caused by the smouldering tendency of the wood fibreboards. Thus, the development of an ETICS with wood fibreboards for multi-storey buildings complying with the requirements would provide a new scope of application for this sustainable insulation material. This paper presents first results of standardised and innovative investigation methods as basis for the development. These investigations and analyses concern the fire behaviour, especially smouldering processes, the plaster system, other constructive protection measures as well as risk and safety analyses.

  6. Safety analysis report for packaging: the ORNL gas-cylinder fire and impact shield

    Evans, J.H.; Levine, D.L.; Eversole, R.E.

    1977-10-01

    The ORNL radioactive gas-cylinder fire and impact shield was designed and fabricated at the Oak Ridge Gaseous Diffusion Plant for the transport of cylinders filled with radioactive gases. The shield was evaluated analytically and experimentally to determine its compliance with the applicable regulations governing containers in which radioactive and fissile materials are transported. Computational and test procedures were used to determine the structural integrity and thermal behavior of the cask relative to the general standards for normal conditions of transport and the standards for hypothetical accident conditions. Results of the evaluation demonstrate that the container is in compliance with the applicable regulations

  7. Safety analysis report for packaging: the ORNL gas-cylinder fire and impact shield

    Evans, J.H.; Levine, D.L.; Eversole, R.E.; Mouring, R.W.

    1983-04-01

    The ORNL gas-cylinder fire and impact shield was designed and fabricated at the Oak Ridge Gaseous Diffusion Plant for the transport of cylinders filled with radioactive gases. The shield was evaluated analytically and experimentally to determine its compliance with the applicable regulations governing containers in which radioactive and fissile materials are transported, and the results are reported herein. Computational and test procedures were used to determine the structural integrity and thermal behavior of the cask relative to the general standards for normal conditions of transport and the standards for hypothetical accident conditions. Results of the evaluation demonstrate that the container is in compliance with the applicable regulations

  8. Safety and dose management during decommissioning of a fire damaged nuclear reactor

    Pomfret, D.G.

    2000-01-01

    Windscale Piles 1 and 2 in Cumbria in the UK were constructed in the early 1950s. They were not intended to produce electricity but were for military purposes only. They were graphite-moderated, air-cooled reactors with horizontal fuel channels fuelled with uranium rods clad in finned aluminium. In October 1957, Windscale Pile 1 suffered a core fire during a planned release of Wigner energy and both Piles were subsequently closed down. Following the fire, Pile 2 was defuelled entirely and as much fuel as was possible was removed from Pile 1. However, it is estimated that up to 15 Te of fuel remains in the core, a large proportion of which is located in the central Fire Affected Zone (FAZ). The condition of the fuel and graphite moderator in the FAZ is not known. It is possible that the moderator could contain voidage, greatly reduced density graphite and fused materials in a disordered matrix. It is probable that there is residual Wigner energy in the graphite. Use of water as part of the attempt to extinguish the fire, together with the possibility that the solidification of molten materials or other local sealing mechanisms could have excluded air mean that uranium hydrides, carbides and other pyrophorics may be present within the core. Pile 1 is now being decommissioned and a considerable amount of preparatory work has already been carried out during Phase 1. Phase 2 decommissioning, which will remove the residual fuel, the moderator and associated steelwork, condition the wastes and place them in a purpose built store is now underway. This work will be carried out for the site licensee, the United Kingdom Energy Authority, by a consortium of British Nuclear Fuels plc, Rolls Royce and NUKEM. This paper will describe the methods to be used to decommission Pile 1 and the systems and procedures which will be used to ensure that it is done safely and with the lowest reasonably practicable environmental impact. It will also describe the methods which will be used to

  9. Fuel Receiving and Storage Station. Nuclear Regulatory Commission's safety evaluation report

    1976-01-01

    The safety evaluation report covers design of structures, components, equipment, and systems; nuclear criticality safety; radiological safety; accident analysis; conduct of operations; quality assurance; common defense and security; financial qualifications; financial protection and indemnity requirements; and technical specifications

  10. Fire safety regulations for nuclear power plants in Germany and the various dimensions of German KTA standardization activities. Is there a benefit today?

    Wittmann, R.

    1998-01-01

    In Germany the mandate for preparing nuclear safety standards is given to the KTA (Nuclear Safety Standards Commission) which has restrictive procedures to definitely ensure consensus principle. The KTA was up to now not in a position to approve comprehensive fire safety relevant standards, although its corresponding program is now 22 years old. KTA 2101.1 ''Basic Principles of Fire Protection in NPPs'' (12/85) is the only one published as valid safety standard. Drafts for 3 additional standards referring fire protection of structural elements, electrical and mechanical components as well as for rescue routes have been agreed upon in working groups, supervised and accepted by the responsible KTA subcommittee, but have not been approved by the full committee of the KTA up to now. Some of these drafts are already more than 5 years old. From the today's point of view the earliest possibility to have a comprehensive and actual set of fire relevant KTA standards will be in the second half of the year 1999. This would then be 24 years after the first KTA decision to start such a program. (author)

  11. Assessment of plutonium storage safety issues at Department of Energy facilities

    1994-01-01

    The Department of Energy (DOE) mission for utilization and storage of nuclear materials has recently changed as a result of the end of the ''Cold War'' era. Past and current plutonium storage practices largely reflect a temporary, in-process, or in-use storage condition which must now be changed to accommodate longer-term storage. This report summarizes information concerning current plutonium metal and oxide storage practices which was presented at the Office of Defense programs (DP) workshop in Albuquerque, New Mexico on May 26-27, 1993 and contained in responses to questions by DP-62 from the field organizations

  12. FIRE SAFETY IN NUCLEAR POWER PLANTS: A RISK-INFORMED AND PERFORMANCE-BASED APPROACH

    AZARM,M.A.; TRAVIS,R.J.

    1999-11-14

    The consideration of risk in regulatory decision-making has long been a part of NRC's policy and practice. Initially, these considerations were qualitative and were based on risk insights. The early regulations relied on good practices, past insights, and accepted standards. As a result, most NRC regulations were prescriptive and were applied uniformly to all areas within the regulatory scope. Risk technology is changing regulations by prioritizing the areas within regulatory scope based on risk, thereby focusing on the risk-important areas. Performance technology, on the other hand, is changing the regulations by allowing requirements to be adjusted based on the specific performance expected and manifested, rather than a prior prescriptive requirement. Consistent with the objectives of risk-informed and performance-based regulatory requirements, BNL evaluated the feasibility of applying risk- and performance-technologies to modifying NRC's current regulations on fire protection for nuclear power plants. This feasibility study entailed several case studies (trial applications). This paper describes the results of two of them. Besides the case studies, the paper discusses an overall evaluation of methodologies for fire-risk analysis to support the risk-informed regulation. It identifies some current shortcomings and proposes some near-term solutions.

  13. FIRE SAFETY IN NUCLEAR POWER PLANTS: A RISK-INFORMED AND PERFORMANCE-BASED APPROACH

    AZARM, M.A.; TRAVIS, R.J.

    1999-01-01

    The consideration of risk in regulatory decision-making has long been a part of NRC's policy and practice. Initially, these considerations were qualitative and were based on risk insights. The early regulations relied on good practices, past insights, and accepted standards. As a result, most NRC regulations were prescriptive and were applied uniformly to all areas within the regulatory scope. Risk technology is changing regulations by prioritizing the areas within regulatory scope based on risk, thereby focusing on the risk-important areas. Performance technology, on the other hand, is changing the regulations by allowing requirements to be adjusted based on the specific performance expected and manifested, rather than a prior prescriptive requirement. Consistent with the objectives of risk-informed and performance-based regulatory requirements, BNL evaluated the feasibility of applying risk- and performance-technologies to modifying NRC's current regulations on fire protection for nuclear power plants. This feasibility study entailed several case studies (trial applications). This paper describes the results of two of them. Besides the case studies, the paper discusses an overall evaluation of methodologies for fire-risk analysis to support the risk-informed regulation. It identifies some current shortcomings and proposes some near-term solutions

  14. Chemical Safety Alert: Safe Storage and Handling of Swimming Pool Chemicals

    Hazards of pool water treatment and maintenance chemicals (e.g., chlorine), and the protective measures pool owners should take to prevent fires, toxic vapor releases, and injuries. Triggered by improper wetting, mixing, or self-reactivity over time.

  15. Information report on nuclear safety and radiation protection within the Aube low and medium activity radioactive waste storage Centre - 2011

    2012-06-01

    After a presentation of the different installations of the Aube waste storage centre, this report describes the different measures regarding nuclear safety, radiation protection and security. It recalls and comments incidents and accidents which occurred within the installations in 2011. It describes the activities of control and survey of releases and of the environment. It describes the management of wastes produced by the centre itself. It indicates the various actions undertaken with respect to information and transparency

  16. Inventory of Safety-related Codes and Standards for Energy Storage Systems with some Experiences related to Approval and Acceptance

    Conover, David R.

    2014-09-11

    The purpose of this document is to identify laws, rules, model codes, codes, standards, regulations, specifications (CSR) related to safety that could apply to stationary energy storage systems (ESS) and experiences to date securing approval of ESS in relation to CSR. This information is intended to assist in securing approval of ESS under current CSR and to identification of new CRS or revisions to existing CRS and necessary supporting research and documentation that can foster the deployment of safe ESS.

  17. The impact of biopreservatives and storage temperature in the quality and safety of minimally processed mixed vegetables for soup.

    Alvarez, María V; Ponce, Alejandra G; Mazzucotelli, Cintia A; Moreira, María R

    2015-03-30

    The combined effects of bioactive agents (tea tree essential oil, propolis extract and gallic acid) and storage temperature on the microbiological and sensory quality of fresh-cut mixed vegetables for soup (celery, leek and butternut squash) were studied with the objective of preserving its quality and safety. Refrigeration temperature was confirmed as the main factor to limit the growth of spoilage and pathogenic microorganisms. Biopreservatives applied on mixed vegetables were effective only when combined with optimal refrigeration temperature (5 °C). Bioactive compounds showed slight effectiveness in controlling the microbiota present in mixed vegetables, although coliforms were greatly reduced by gallic acid and propolis treatments, achieving 0.5-2 log unit reductions during storage. Also, these agents showed antimicrobial activity against endogenous Escherichia coli and inoculated E. coli O157:H7, exerting a bacteriostatic effect and reducing population counts by 0.9-1.2 log CFU g(-1) at 10 days of refrigerated storage. The combination of propolis treatment with refrigerated storage conditions effectively preserved the sensory quality and prolonged the sensory shelf life of fresh-cut mixed vegetables by 3 days. The use of natural agents such as propolis extract to preserve the quality and safety of mixed vegetables for soup might be an interesting option to address the concerns of the consumer about the use of synthetic chemical antimicrobials potentially harmful to health. © 2014 Society of Chemical Industry.

  18. Qualitative Analysis Results for Applications of a New Fire Probabilistic Safety Assessment Method to Ulchin Unit 3

    Kang, Daeil; Kim, Kilyoo; Jang, Seungcheol

    2013-01-01

    The fire PRA Implementation Guide has been used for performing a fire PSA for NPPs in Korea. Recently, US NRC and EPRI developed a new fire PSA method, NUREG/CR-6850, to provide state-of-the-art methods, tools, and data for the conduct of a fire PSA for a commercial nuclear power plant (NPP). Due to the limited budget and man powers for the development of KSRP, hybrid PSA approaches, using NUREG/CR-6850 and Fire PRA Implementation Guide, will be employed for conducting a fire PSA of Ulchin Unit 3. In this paper, the qualitative analysis results for applications of a new fire PSA method to Ulchin Unit 3 are presented. This paper introduces the qualitative analysis results for applications of a new fire PSA method to Ulchin Unit 3. Compared with the previous industry, the number of fire areas for quantification identified and the number of equipment selected has increased

  19. The management of building fire safety towards the sustainability of Malaysian public universities

    Ebenehi, I. Y.; Mohamed, S.; Sarpin, N.; Masrom, M. A. N.; Zainal, R.; Azmi, M. A. Mohd

    2017-11-01

    Recently, there had been reduction in annual budgetary allocations to public universities in Malaysia due to some economic tensions. This situation had left many institutions in question with the options of scaling down their expenses as well as sourcing for other means of meeting up with the shortfalls in allocated funds. Hence, it affects the sustainability of the building itself. This paper is an attempt to look at the possibility of reducing incidents that could lead to expending unbudgeted fund to rehabilitating property unfortunately destroyed by fire on campus, in addition to limiting risk to life and interruption of academic and business activities. Several research had been conducted on FSM, nevertheless very few consider Higher Education Institutions (HEI)s holistically. Hence this research intends to fill that gap.

  20. Safety analysis report for packaging: the ORNL lithium hydroxide fire and impact shield

    Evans, J.H.; Eversole, R.E.; Just, R.A.; Schaich, R.W.

    1984-07-01

    The ORNL Lithium Hydroxide Fire and Impact Shield and its packaging were designed and fabricated at Oak Ridge National Laboratory to permit the transport of Type B quantities of radioactive material and limited quantities of fissionable material. The shield and its packaging were evaluated analytically and experimentally to determine its compliance with the applicable regulations governing containers in which radioactive and fissile materials are transported, and that evaluation is the subject of this report. Computational and test procedures were used to determine the structural integrity and thermal behavior of the shield relative to the general standards for normal conditions of transport and the standards for the hypothetical accident conditions. The results of the evaluation demonstrate that the shield and its packaging are in compliance with the applicable regulations. 16 references, 8 figures, 5 tables

  1. Safety analysis report for packaging: the ORNL lithium hydroxide fire and impact shield

    Evans, J.H.; Eversole, R.E.; Just, R.A.

    1977-11-01

    The ORNL lithium hydroxide fire and impact shield was designed and fabricated at Oak Ridge National Laboratory to permit the transport of Type B and large quantities of radioactive material and limited quantities of fissionable material. The shield was evaluated analytically and experimentally to determine its compliance with the applicable regulations governing containers in which radioactive and fissile materials are transported, and that evaluation is the subject of this report. Computational and test procedures were used to determine the structural integrity and thermal behavior of the shield relative to the general standards for normal conditions of transport and the standards for the hypothetical accident conditions. The results of the evaluation demonstrate that the shield is in compliance with the applicable regulations

  2. Long-term ecosystem nitrogen storage and soil nitrogen availability in post-fire lodgepole pine ecosystems

    Erica A. H. Smithwick; Daniel M. Kashian; Michael G. Ryan; Monica G.  Turner

    2009-01-01

    Long-term, landscape patterns in inorganic nitrogen (N) availability and N stocks following infrequent, stand-replacing fire are unknown but are important for interpreting the effect of disturbances on ecosystem function. Here, we present results from a replicated chronosequence study in the Greater Yellowstone Ecosystem (Wyoming, USA) directed at measuring inorganic N...

  3. Strategic Petroleum Reserve, West Hackberry oil storage cavern fire and spill of September 21, 1978: an environmental assessment. Final report

    Taylor, A

    1980-02-29

    This report summarizes an environmental assessment of the fire and oil spill at the Strategic Petroleum Reserve site, West Hackberry, Louisiana. Subjective identification of oil contaminated habitats was supported by a more rigorous classification of samples utilizing discriminant analysis. Fourteen contaminated stations were identified along the shore of Black Lake just north and west of Wellpad 6, encompassing approximately 9 hectares. Seasonal variation in the structures of marsh and lake bottom communities in this contaminated area were not generally distinguishable from that of similar communities in uncontaminated habitats along the southern and southeastern shores of Black Lake. The major impact of spilled oil on the marsh vegetation was to accelerate the natural marsh deterioration which will eventually impact animals dependent on marsh vegetation for habitat structure. Vanadium, the predominate trace metal in the oil, and pyrogenic products due to the fire were found at the most distant sampling site (5 km) from Cavern 6 during Phase I, but were not detected downwind of the fire in excess of background levels in the later phases. Remote sensing evaluation of vegetation under the plume also indicated that stress existed immediately after the fire, but had disappeared by the end of the 1-year survey.

  4. Analysis of sodium pool fire in SFEF for assessing the limiting pool fire

    Mangarjuna Rao, P.; Ramesh, S.S.; Nashine, B.K.; Kasinathan, N.; Chellapandi, P.

    2011-01-01

    Accidental sodium leaks and resultant sodium fires in Liquid Metal Fast Breeder Reactor (LMFBR) systems can create a threat to the safe operation of the plant. To avoid this defence-in depth approach is implemented from the design stage of reactor itself. Rapid detection of sodium leak and fast dumping of the sodium into the storage tank of a defective circuit, leak collection trays, adequate lining of load bearing structural concrete and extinguishment of the sodium fire are the important defensive measures in the design, construction and operation of a LMFBR for protection against sodium leaks and their resultant fires. Evaluation of sodium leak events and their consequences by conducting large scale engineering experiments is very essential for effective implementation of the above protection measures for sodium fire safety. For this purpose a Sodium Fire Experimental Facility (SFEF) is constructed at SED, IGCAR. SFEF is having an experimental hall of size 9 m x 6 m x 10 m with 540 m 3 volume and its design pressure is 50 kPa. It is a concrete structure and provided with SS 304 liner, which is fixed to the inside surfaces of walls, ceiling and floor. A leak tight door of size (1.8 m x 2.0 m) is provided to the experimental hall and the facility is provided with a sodium equipment hall and a control room. Experimental evaluation of sodium pool fire consequences is an important activity in the LMFBR sodium fire safety related studies. An experimental program has been planned for different types of sodium fire studies in SFEF. A prior to that numerical analysis have been carried out for enclosed sodium pool fires using SOFIRE-II sodium pool fire code for SFEF experimental hall configuration to evaluate the limiting pool fire. This paper brings out results of the analysis carried out for this purpose. Limiting pool fire of SFEF depends on the exposed surface area of the pool, amount of sodium in the pool, oxygen concentration and initial sodium temperature. Limiting

  5. Development of safety evaluation technology for fire and explosion in reprocessing plant

    Miura, Akihiko

    2005-01-01

    Based on some lessons learned from the accidents in the reprocessing plant all over the world, Japan Nuclear Cycle Development Institute (JNC) has researched and developed the safety technologies for the reprocessing plants and its related facilities. This paper describes some accidental information around the reprocessing plants and its related research activities in JNC. (author)

  6. An optimization model for carbon capture & storage/utilization vs. carbon trading: A case study of fossil-fired power plants in Turkey.

    Ağralı, Semra; Üçtuğ, Fehmi Görkem; Türkmen, Burçin Atılgan

    2018-06-01

    We consider fossil-fired power plants that operate in an environment where a cap and trade system is in operation. These plants need to choose between carbon capture and storage (CCS), carbon capture and utilization (CCU), or carbon trading in order to obey emissions limits enforced by the government. We develop a mixed-integer programming model that decides on the capacities of carbon capture units, if it is optimal to install them, the transportation network that needs to be built for transporting the carbon captured, and the locations of storage sites, if they are decided to be built. Main restrictions on the system are the minimum and maximum capacities of the different parts of the pipeline network, the amount of carbon that can be sold to companies for utilization, and the capacities on the storage sites. Under these restrictions, the model aims to minimize the net present value of the sum of the costs associated with installation and operation of the carbon capture unit and the transportation of carbon, the storage cost in case of CCS, the cost (or revenue) that results from the emissions trading system, and finally the negative revenue of selling the carbon to other entities for utilization. We implement the model on General Algebraic Modeling System (GAMS) by using data associated with two coal-fired power plants located in different regions of Turkey. We choose enhanced oil recovery (EOR) as the process in which carbon would be utilized. The results show that CCU is preferable to CCS as long as there is sufficient demand in the EOR market. The distance between the location of emission and location of utilization/storage, and the capacity limits on the pipes are an important factor in deciding between carbon capture and carbon trading. At carbon prices over $15/ton, carbon capture becomes preferable to carbon trading. These results show that as far as Turkey is concerned, CCU should be prioritized as a means of reducing nation-wide carbon emissions in an

  7. Studies about pressure variations and their effects during a fire in a confined and forced ventilated enclosure: safety consequences in the case of a nuclear facility

    Hugues Pretrel; Laurent Bouilloux; Jerome Richard

    2005-01-01

    Full text of publication follows: In a nuclear facility, the cells are confined and forced ventilated and some of them are equipped with isolation devices designed to close in case of a fire. So, if a fire occurred, the pressure variations in the cell could be important. This contribution presents the safety concerns related to pressure variation effects (propagation of smokes and/or flames through the fire barriers, propagation of radioactive material) and the research works carried out by the french 'Institut de Radioprotection et de Surete Nucleaire' (IRSN) on this topic. These research works are composed of two different studies. The first study permits to quantify the overpressure and depression levels and to reveal the influence of the fire heat release rate (HRR), of the characteristics of the cell, of the ventilation layout (especially the airflow resistances of the ventilation branches) and of the control of the fire dampers. This study is based on three sets of experimental tests performed in three large-scale facilities of various dimensions (3600 m3, 400 m3 and 120 m3 in volume) and with several settings of the ventilation network. The analysis focuses on the conditions that lead to significant overpressure and depression peaks and identifies the level of fire HRR and airflow resistances for which pressure peaks may become a safety concern. The second study allows to characterise the behaviour of sectorisation and containment equipments subject to pressure stresses. The mechanical resistance of some equipments (doors, fire dampers) subject to pressure stresses as well as the aeraulic behaviour of this equipment (gas leak rates) are determined in order to assess the potential transfer of contamination in the ventilation networks. (authors)

  8. Solving the Problem of Multiple-Criteria Building Design Decisions with respect to the Fire Safety of Occupants: An Approach Based on Probabilistic Modelling

    Egidijus Rytas Vaidogas

    2015-01-01

    Full Text Available The design of buildings may include a comparison of alternative architectural and structural solutions. They can be developed at different levels of design process. The alternative design solutions are compared and ranked by applying methods of multiple-criteria decision-making (MCDM. Each design is characterised by a number of criteria used in a MCDM problem. The paper discusses how to choose MCDM criteria expressing fire safety related to alternative designs. Probability of a successful evacuation of occupants from a building fire and difference between evacuation time and time to untenable conditions are suggested as the most important criteria related to fire safety. These two criteria are treated as uncertain quantities expressed by probability distributions. Monte Carlo simulation of fire and evacuation processes is natural means for an estimation of these distributions. The presence of uncertain criteria requires applying stochastic MCDM methods for ranking alternative designs. An application of the safety-related criteria is illustrated by an example which analyses three alternative architectural floor plans prepared for a reconstruction of a medical building. A MCDM method based on stochastic simulation is used to solve the example problem.

  9. Construction safety in DOE. Part 1, Students guide

    Handwerk, E C

    1993-08-01

    This report is the first part of a compilation of safety standards for construction activities on DOE facilities. This report covers the following areas: general safety and health provisions; occupational health and environmental control/haz mat; personal protective equipment; fire protection and prevention; signs, signals, and barricades; materials handling, storage, use, and disposal; hand and power tools; welding and cutting; electrical; and scaffolding.

  10. Fire Risk Assessment in Germany

    Berg, H. P.

    2000-01-01

    Quantitative fire risk assessment can serve as an additional tool to assess the safety level of a nuclear power plant (NPP) and to set priorities for fire protection improvement measures. The recommended approach to be applied within periodic safety reviews of NPPs in Germany starts with a screening process providing critical fire zones in which a fully developed fire has the potential to both cause an initiating event and impair the function of at least one component or system critical to safety. The second step is to perform a quantitative analysis using a standard event tree has been developed with elements for fire initiation, ventilation of the room, fire detection, fire suppression, and fire propagation. In a final step, the fire induced frequency of initiating events, the main contributors and the calculated hazard state frequency for the fire event are determined. Results of the first quantitative fire risk studies performed in Germany are reported. (author)

  11. Diesel oil safety stock in storage and distribution terminals: a case study: Porto Velho/Rio, Brazil

    Freitas, Rubens C. [Agencia Nacional do Petroleo, Gas Natural e Biocombustiveis (ANP), Rio de Janeiro, RJ (Brazil); D' agosto, Marcio A. [Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE/UFRJ), RJ (Brazil)

    2012-07-01

    This paper presents a methodology for calculating diesel oil safety stock in distributor terminals located in the northern of Brazil, applied on a case study for terminals in the state of Rondonia. From the mapping of logistic flows related to transport and storage of diesel oil, the risk factors that cause uncertainties in lead time were analyzed and quantified. Through a research conducted among economic agents (producers, distributors and carriers) operating in the region, it was measured the relevance and impact of risk factors on the safety stock in the terminals. The safety stock was calculated by the classical equation of inventories, as well as by the methodology proposed in this paper. The difference between the two methods has unveiled inefficiencies derived from uncertainties in lead time. Recommendations of actions to mitigate the risk factors are included at the end of this paper. (author)

  12. Pre-conceptual study on the review framework for the radiation shielding safety of the PWR spent fuel cask interim storage in Korea

    Kim, Byeong-Soo; Jeong, Jae-Hak; Jeong, Chan-Woo

    2006-01-01

    In Korea, 20 nuclear power plants are in operation and lots of spent fuels are on the onsite storage. The onsite storage capacity in Korea is supposed to be full around at the year of 2016 and interim storage facilities could be considered to be constructed before 2016. A review framework to evaluate the radiation shielding safety of the interim storage facilities is developed in this study. It includes acceptance criteria, review procedures and activities of independent analyses. A case study is performed to apply the review framework. Modeling the review reference storage, evaluating the source terms and calculating the photon fluxes are performed. It is shown that the application of the review framework could satisfy the regulatory demand that would arise in the near future in the review area of the radiation shielding safety of the interim storage in Korea. (author)

  13. Extra-regulatory accident safety evaluation for the PWR S/F transport and storage system

    Seo, K. S.; Lee, J. C.; Bang, K. S.; Choi, W. S.; Lee, S. H.; Seo, J. S.; Kim, K. Y.; Jeon, J. E.

    2011-06-01

    In the field of high speed crash, high speed impact analyses and test were performed for two systems, the dual purpose metal cask and the concrete cask considering the aircraft crash condition. Through the tests, the procedure and methodology of the assessment were successfully validated. In the field of transient fire, the computer simulation method for transient fire was drawn through the overseas status and methodology analysis. In the field of cumulative damage evaluation for transport accident, the analysis technique for assessment for cumulative damages which occurred from successive accident conditions was developed and proposed. And the sequential tests for the dual purpose cask were performed

  14. Fire protection in nuclear power plants

    1979-01-01

    The Safety Guide gives design and some operational guidance for protection from fire and fire-related explosions in nuclear power plants (NPP). It confines itself to fire protection of items important to safety, leaving the aspects of fire protection not related to safety in NPP to be decided upon the basis of the national practices and regulations

  15. Application of Framework for Integrating Safety, Security and Safeguards (3Ss) into the Design Of Used Nuclear Fuel Storage Facility

    Badwan, Faris M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Demuth, Scott F [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-01-06

    Department of Energy’s Office of Nuclear Energy, Fuel Cycle Research and Development develops options to the current commercial fuel cycle management strategy to enable the safe, secure, economic, and sustainable expansion of nuclear energy while minimizing proliferation risks by conducting research and development focused on used nuclear fuel recycling and waste management to meet U.S. needs. Used nuclear fuel is currently stored onsite in either wet pools or in dry storage systems, with disposal envisioned in interim storage facility and, ultimately, in a deep-mined geologic repository. The safe management and disposition of used nuclear fuel and/or nuclear waste is a fundamental aspect of any nuclear fuel cycle. Integrating safety, security, and safeguards (3Ss) fully in the early stages of the design process for a new nuclear facility has the potential to effectively minimize safety, proliferation, and security risks. The 3Ss integration framework could become the new national and international norm and the standard process for designing future nuclear facilities. The purpose of this report is to develop a framework for integrating the safety, security and safeguards concept into the design of Used Nuclear Fuel Storage Facility (UNFSF). The primary focus is on integration of safeguards and security into the UNFSF based on the existing Nuclear Regulatory Commission (NRC) approach to addressing the safety/security interface (10 CFR 73.58 and Regulatory Guide 5.73) for nuclear power plants. The methodology used for adaptation of the NRC safety/security interface will be used as the basis for development of the safeguards /security interface and later will be used as the basis for development of safety and safeguards interface. Then this will complete the integration cycle of safety, security, and safeguards. The overall methodology for integration of 3Ss will be proposed, but only the integration of safeguards and security will be applied to the design of the

  16. Fire detection in warehouse facilities

    Dinaburg, Joshua

    2013-01-01

    Automatic sprinklers systems are the primary fire protection system in warehouse and storage facilities. The effectiveness of this strategy has come into question due to the challenges presented by modern warehouse facilities, including increased storage heights and areas, automated storage retrieval systems (ASRS), limitations on water supplies, and changes in firefighting strategies. The application of fire detection devices used to provide early warning and notification of incipient warehouse fire events is being considered as a component of modern warehouse fire protection.Fire Detection i

  17. Fire Situations and Prevention Measures of residential building

    Zhou Baixia

    2017-01-01

    Full Text Available The proportion of residential building is the largest in all buildings. With the development of urbanization, residential building fires are at high momentum. The paper lists the residential building fires and the number of casualties’ proportion to total fires from 2011 to 2014, analyzing the high incidence causes of the fires and casualties and putting forward suggestions and countermeasures including carrying out fire safety education to improve the fire safety awareness of residents, fulfilling responsibility to enhancing fire safety management capabilities, perfecting fire apparatus to develop fire safety environment and enhancing public awareness of fire safety, equipping evacuation equipments to promote response ability to deal with disasters etc.

  18. Long-term energy and climate implications of carbon capture and storage deployment strategies in the US coal-fired electricity fleet.

    Sathre, Roger; Masanet, Eric

    2012-09-04

    To understand the long-term energy and climate implications of different implementation strategies for carbon capture and storage (CCS) in the US coal-fired electricity fleet, we integrate three analytical elements: scenario projection of energy supply systems, temporally explicit life cycle modeling, and time-dependent calculation of radiative forcing. Assuming continued large-scale use of coal for electricity generation, we find that aggressive implementation of CCS could reduce cumulative greenhouse gas emissions (CO(2), CH(4), and N(2)O) from the US coal-fired power fleet through 2100 by 37-58%. Cumulative radiative forcing through 2100 would be reduced by only 24-46%, due to the front-loaded time profile of the emissions and the long atmospheric residence time of CO(2). The efficiency of energy conversion and carbon capture technologies strongly affects the amount of primary energy used but has little effect on greenhouse gas emissions or radiative forcing. Delaying implementation of CCS deployment significantly increases long-term radiative forcing. This study highlights the time-dynamic nature of potential climate benefits and energy costs of different CCS deployment pathways and identifies opportunities and constraints of successful CCS implementation.

  19. Burns and fires in South Africa's informal settlements: Have approved kerosene stoves improved safety?

    Kimemia, David; van Niekerk, Ashley; Govender, Rajen; Seedat, Mohamed

    2018-06-01

    This study is a follow-on to an intervention project that implemented South African Bureau of Standards approved kerosene stoves and safety education in 150 households of a Johannesburg informal settlement. An investigation conducted 12 months later established that 43 stoves had operational defects, yet 23 households continued using the faulty appliances. This study focuses on (1) the psychological and behavioural factors associated with continued use of faulty stoves by the 23 households, and (2), the specific technical failures of these stoves. The study involved one-on-one recall interviews with the households using defective stoves (N=21) and laboratory-based stove tests for seven of the affected appliances. The results indicate that the stoves had defects in critical safety features such as flame control and the self-extinguishing mechanism. Four stove malfunctions of minor burn affect were reported in the study. Continued use of the damaged stoves was significantly associated with the time from receipt of the stove to detection of first failure: stoves that failed later on were more significantly likely to remain in use as compared to those that failed sooner. The findings point to the need for strengthening enforcement of appliance standards, public education on kerosene stove use, and structural change for the energy-poor. Copyright © 2017 Elsevier Ltd and ISBI. All rights reserved.

  20. Laboratory Evaluation of Gas-Fired Tankless and Storage Water Heater Approaches to Combination Water and Space Heating

    Kingston, T. [Gas Technology Inst., Des Plaines, IL (United States); Scott, S. [Gas Technology Inst., Des Plaines, IL (United States)

    2013-03-01

    Homebuilders are exploring more cost-effective combined space and water heating systems (combo systems) with major water heater manufacturers that are offering pre-engineered forced air space heating combo systems. In this project, unlike standardized tests, laboratory tests were conducted that subjected condensing tankless and storage water heater based combo systems to realistic, coincidental space and domestic hot water loads and found that the tankless combo system maintained more stable DHW and space heating temperatures than the storage combo system, among other key findings.